Sample records for reference point l1

  1. Experimental Testing of a Generic Submarine Model in the DSTO Low Speed Wind Tunnel. Phase 2

    DTIC Science & Technology

    2014-03-01

    axis, z-axis (Nm) l Model reference length (1.35 m) L Lift force (N) MRP Moment Reference Point q Dynamic pressure       2 2 1 Uρ (Pa...moment reference point ( MRP ). The moment reference point was defined as the mid-length position on the centre-line of the model. Figure 5 presents the

  2. Method of recertifying a loaded bearing member

    NASA Technical Reports Server (NTRS)

    Allison, Sidney G. (Inventor)

    1992-01-01

    A method is described of recertifying a loaded bearing member using ultrasound testing to compensate for different equipment configurations and temperature conditions. The standard frequency F1 of a reference block is determined via an ultrasonic tone burst generated by a first pulsed phased locked loop (P2L2) equipment configuration. Once a lock point number S is determined for F1, the reference frequency F1a of the reference block is determined at this lock point number via a second P2L2 equipment configuration to permit an equipment offset compensation factor Fo1=((F1-F1a)/F1)(1000000) to be determined. Next, a reference frequency F2 of the unloaded bearing member is determined using a second P2L2 equipment configuration and is then compensated for equipment offset errors via the relationship F2+F2(Fo1)/1000000. A lock point number b is also determined for F2. A resonant frequency F3 is determined for the reference block using a third P2L2 equipment configuration to determine a second offset compensation factor F02=((F1-F3)/F1) 1000000. Next the resonant frequency F4 of the loaded bearing member is measured at lock point number b via the third P2L2 equipment configuration and the bolt load determined by the relationship (-1000000)CI(((F2-F4)/F2)-Fo2), wherein CI is a factor correlating measured frequency shift to the applied load. Temperature compensation is also performed at each point in the process.

  3. Promises and Obstacles of L1 Use in Language Classrooms: A State-of-the-Art Review

    ERIC Educational Resources Information Center

    Ghobadi, Mehdi; Ghasemi, Hadi

    2015-01-01

    Translation and language teaching techniques which take language learners' first language (L1) as point of reference for teaching the second language (L2) have been long discouraged on the ground that these teaching techniques would end in the fossilization of L2 structure forms in the learner's Interlanguage system. However, in recent years, the…

  4. 30-MM Tubular Projectile

    DTIC Science & Technology

    1984-10-01

    on this point. 10 *. Ir- , .- * .. - , -. . 7 t , . - %, ’. . .. . l. , * H k " 1 . F *. i References 1. Stephen J. Price, Rotating Band for High...0% ON 0 w 41 6 *l *- -- 4* N N H .- .𔃾-4P- ’ ’-൝ 0 tn K Table 10. Inspection of Hisparm Suiza sabot (mass in graw ) 12 Pusher plate * "’ Item 1 2 3

  5. Point-of-care device to diagnose and monitor neonatal jaundice in low-resource settings

    PubMed Central

    Keahey, Pelham A.; Simeral, Mathieu L.; Schroder, Kristofer J.; Bond, Meaghan M.; Mtenthaonnga, Prince J.; Miros, Robert H.; Dube, Queen

    2017-01-01

    Newborns are at increased risk of jaundice, a condition in which excess bilirubin accumulates in blood. Left untreated, jaundice can lead to neurological impairment and death. Jaundice resulting from unconjugated hyperbilirubinemia is easily treated with exposure to blue light, and phototherapy systems have been developed for low-resource settings; however, there are no appropriate solutions to diagnose and monitor jaundice in these settings. To address this need we present BiliSpec, a low-cost reader and disposable lateral flow card designed to measure the concentration of total bilirubin from several drops of blood at the point of care. We evaluated the performance of BiliSpec, using blood from normal volunteers spiked with varying amounts of bilirubin; results measured using BiliSpec correlated well with a reference laboratory bilirubinometer (r = 0.996). We then performed a pilot clinical study using BiliSpec to measure total bilirubin in neonates at risk for jaundice at Queen Elizabeth Central Hospital in Blantyre, Malawi. Concentrations measured using BiliSpec correlated well with those measured using a laboratory reference standard in 94 patient samples ranging from 1.1 mg/dL to 23.0 mg/dL in concentration (r = 0.973). The mean difference between bilirubin levels measured with BiliSpec and the reference standard was 0.3 mg/dL (95% CI: −1.7–2.2 mg/dL). PMID:29203650

  6. Analysis of Ejection Seat Stability Using Easy Program. Volume I.

    DTIC Science & Technology

    1980-09-01

    BODY AXiS FURCE COMPONENT. L ACTING ON THE AiRPLANc FROM THE CATAPULT (Ld) C ILA1(3) - PORT ONE X,Y,L AIRPLANE BODY AXIS TORQUE COMPONENTS C ACrINu...THE AIRPLANE (FT) C EAPI3) - EARTH TO AIRPLANc . EULER ANGLES (DEG) C SKPt3) - XtYZ EARTh POSITIGN VECTOR OF THE SEAT REFERENCE L POINT (FT) f- LST(3

  7. Electromagnetic Scattering by an Exponentially Distributed Rough Surface with the Introduction of a Rough Surface Generation Technique

    DTIC Science & Technology

    1987-12-01

    d integer corrow, corcol , refrow, refcol C Create lower triangle of corr. matrix (symetric matrix) do 33 i~l,n2 C calculate the row point (i) is in...reference Fig.(21)) corrow = (((i-l)/n)+1) C claculate the column point (i) is in corcol = i-(corrow-l)*n) write(6,*) i do 31 jl,i C calculate the row...refrow)*space C the horizontal distance (b) b = ( corcol -refcol)*space 14 d = sqrt(a**2+b**2) S coeff(i,j) = e%-P(-d**2) 31 ]i<ontiinue .3 crnt inue

  8. 76 FR 37808 - PJM Interconnection, L.L.C.; Notice of Discussion Topics for Staff Technical Conference

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-06-28

    ... performance measurement of demand response in PJM's capacity market, the Reliability Pricing Model (RPM). \\1...'s April 7, 2011 filing, which proposes to modify the reference point of capacity demand response... less than the customer's Peak Load Contribution (PLC).\\2\\ \\2\\ PJM describes the PLC as the average of...

  9. Accuracy of a continuous noninvasive hemoglobin monitor in intensive care unit patients.

    PubMed

    Frasca, Denis; Dahyot-Fizelier, Claire; Catherine, Karen; Levrat, Quentin; Debaene, Bertrand; Mimoz, Olivier

    2011-10-01

    To determine whether noninvasive hemoglobin measurement by Pulse CO-Oximetry could provide clinically acceptable absolute and trend accuracy in critically ill patients, compared to other invasive methods of hemoglobin assessment available at bedside and the gold standard, the laboratory analyzer. Prospective study. Surgical intensive care unit of a university teaching hospital. Sixty-two patients continuously monitored with Pulse CO-Oximetry (Masimo Radical-7). None. Four hundred seventy-one blood samples were analyzed by a point-of-care device (HemoCue 301), a satellite lab CO-Oximeter (Siemens RapidPoint 405), and a laboratory hematology analyzer (Sysmex XT-2000i), which was considered the reference device. Hemoglobin values reported from the invasive methods were compared to the values reported by the Pulse CO-Oximeter at the time of blood draw. When the case-to-case variation was assessed, the bias and limits of agreement were 0.0±1.0 g/dL for the Pulse CO-Oximeter, 0.3±1.3g/dL for the point-of-care device, and 0.9±0.6 g/dL for the satellite lab CO-Oximeter compared to the reference method. Pulse CO-Oximetry showed similar trend accuracy as satellite lab CO-Oximetry, whereas the point-of-care device did not appear to follow the trend of the laboratory analyzer as well as the other test devices. When compared to laboratory reference values, hemoglobin measurement with Pulse CO-Oximetry has absolute accuracy and trending accuracy similar to widely used, invasive methods of hemoglobin measurement at bedside. Hemoglobin measurement with pulse CO-Oximetry has the additional advantages of providing continuous measurements, noninvasively, which may facilitate hemoglobin monitoring in the intensive care unit.

  10. Option for Treatment and Disposal of Contaminated Sediments from New York/New Jersey Harbor

    DTIC Science & Technology

    1994-01-01

    Miscellaneous paper ; EL-94-1) Includes bibliographical references. 1. Marine pollution -- Atlantic Coast (N.Y.) 2. Dredging -- Atlantic Coast (N.J...former chemical manufacturing plant located in Newark, NJ. These studies do not provide sufficient data to character- ize the distribution of dioxins...Reference Molecular weight. gmo "l 321.97 Wlndholtz 1983 Physical state @ 20 "C Solid. colorless needles with Windholtz 1983 no odor Meltng point, C 305 Schroy

  11. Statistical Inference on Optimal Points to Evaluate Multi-State Classification Systems

    DTIC Science & Technology

    2014-09-18

    vs2+ ( dbcm3 ˆ 2 ) *vm3+( dbcs3 ˆ 2 ) * vs3 80 VETA <−VBCA+VBC EETA<−EBCA−EBC 82 W<− (EETA−TV) / s q r t ( VETA ) # T e s t p−v a l u e − t o compare t o a...event set, E = (ε1, ε2, ..., εk) to k distinct elements of a label set, L = (l1, l2, ..., lk) . These partitions may be referred to as classes. For...set of features, F = ( f1, f2, ..., fm) . These features are then used to assign the different elements from E to the respective labels, L , (A : E → F

  12. Operation TUMBLER-SNAPPER 1952

    DTIC Science & Technology

    1982-06-14

    coordinates are used in this report, as seen in table 1-1. The first three digits refer to I point on an east-west axis, and the second throe digits ...8217icultural ,ech S’tte ’No,. a4inlovvi as t ;’ib i Libary U ’ aerSji ’, T’" Lbra ": 2N L ibrn "Ne•w 5e,•t ’tall I it’ra ’vr Vn Ver t 1 .o0 ,rthl ’a l

  13. Foundational Aero Research for Development of Efficient Power Turbines With 50% Variable-speed Capability

    DTIC Science & Technology

    2011-02-01

    expected, with increased loading (or reduced axial -chord to pitch ratio for a given turning). In addition to minimizing design-point loss due to...5  Figure 2. Computed loading diagrams and Reynolds lapse rates for aft- (L1A) and mid- loaded (L1M) LPT blading (Clark et al., 2009...reference 22 in Welch, 2010) accomplishing the same 95° flow turning at high aerodynamic loading (Z = 1.34). .................8  Figure 3. Computed 2-D

  14. Measurement of cardiac troponin I in healthy lactating dairy cows using a point of care analyzer (i-STAT-1).

    PubMed

    Labonté, Josiane; Roy, Jean-Philippe; Dubuc, Jocelyn; Buczinski, Sébastien

    2015-06-01

    Cardiac troponin I (cTnI) has been shown to be an accurate predictor of myocardial injury in cattle. The point-of-care i-STAT 1 immunoassay can be used to quantify blood cTnI in cattle. However, the cTnI reference interval in whole blood of healthy early lactating dairy cows remains unknown. To determine a blood cTnI reference interval in healthy early lactating Holstein dairy cows using the analyzer i-STAT 1. Forty healthy lactating dairy Holstein cows (0-60 days in milk) were conveniently selected from four commercial dairy farms. Each selected cow was examined by a veterinarian and transthoracic echocardiography was performed. A cow-side blood cTnI dosage was measured at the same time. A bootstrap statistical analysis method using unrestricted resampling was used to determine a reference interval for blood cTnI values. Forty healthy cows were recruited in the study. Median blood cTnI was 0.02 ng/mL (minimum: 0.00, maximum: 0.05). Based on the bootstrap analysis method with 40 cases, the 95th percentile of cTnI values in healthy cows was 0.036 ng/mL (90% CI: 0.02-0.05 ng/mL). A reference interval for blood cTnI values in healthy lactating cows was determined. Further research is needed to determine whether cTnI blood values could be used to diagnose and provide a prognosis for cardiac and noncardiac diseases in lactating dairy cows. Copyright © 2015 Elsevier B.V. All rights reserved.

  15. DSCOVR: A New Perspective for Earth Observations from Space. Synergism and Complementarity with Existing Platforms

    NASA Astrophysics Data System (ADS)

    Valero, F. P.

    2011-12-01

    The Sun-Earth Lagrange points L-1 and L-2 mark positions where the gravitational pull of the Earth and Sun precisely equals the centripetal force required to rotate with the Earth about the Sun with the same orbital period as the Earth. Therefore, a satellite maintained at one of these Lagrange points would keep the same relative position to the Sun and the Earth and be able to observe most points on the planet as the Earth rotates during the day. L-1 and L-2 are of particular interest because a satellite at either location can easily be maintained near the Sun-Earth line and views the entire daytime hemisphere from L-1 and the entire nighttime hemisphere from L-2. Since L-1 and L-2 are in the ecliptic plane, synoptic, high temporal-resolution observations would be obtained as every point on the planet, including both polar regions, transits from sunrise to sunset (L-1) or from sunset to sunrise (L-2). In summary, a pair of deep-space observatories, one at L-1 (daytime) and one at L-2 (nighttime), could acquire minute by minute climate quality data for essentially every point on Earth, all observations simultaneously for the whole planet. Such unique attributes are incorporated in the Deep Space Climate Observatory (DSCOVR) that will systematically observe climate drivers (radiation, aerosols, ozone, clouds, oxygen A-band) from L-1 in ways not possible but synergistically complementary with platforms in Low Earth Orbit (LEO) or Geostationary Earth Orbit (GEO). The combination of Solar Lagrange Points (located in the ecliptic plane) GEO (located in the equatorial plane) and LEO platforms would certainly provide a powerful observational tool as well as enriched data sets for Earth sciences. Such synergism is greatly enhanced when one considers the potential of utilizing LEO, GEO, and Lagrange point satellites as components of an integrated observational system. For example, satellites at L-1 and L-2 will view the Earth plus the Moon while simultaneously having in their fields of view (at one time or another) all Earth-orbiting and GEO satellites. This view offers the opportunity to use the Moon as a comparison reference that can in turn be shared with all other Earth observation satellites. The L-1 and L-2 observatories can become important links between LEO and GEO satellites while at the same time providing the data necessary to build an integrated Earth observational system. A synergistic, integrated system composed of LEO, GEO, L-1 and L-2 platforms is likely the way of the future.

  16. Graphite furnace atomic absorption spectrometric determination of vanadium after cloud point extraction in the presence of graphene oxide

    NASA Astrophysics Data System (ADS)

    López-García, Ignacio; Marín-Hernández, Juan José; Hernández-Córdoba, Manuel

    2018-05-01

    Vanadium (V) and vanadium (IV) in the presence of a small concentration of graphene oxide (0.05 mg mL-1) are quantitatively transferred to the coacervate obtained with Triton X-114 in a cloud point microextraction process. The surfactant-rich phase is directly injected into the graphite atomizer of an atomic absorption spectrometer. Using a 10-mL aliquot sample and 150 μL of a 15% Triton X-114 solution, the enrichment factor for the analyte is 103, which results in a detection limit of 0.02 μg L-1 vanadium. The separation of V(V) and V(IV) using an ion-exchanger allows speciation of the element at low concentrations. Data for seven reference water samples with certified vanadium contents confirm the reliability of the procedure. Several beer samples are also analyzed, those supplied as canned drinks showing low levels of tetravalent vanadium.

  17. The 'new normal': relativity of quality of life judgments in individuals with bipolar disorder-a qualitative study.

    PubMed

    Morton, Emma; Michalak, Erin; Hole, Rachelle; Buzwell, Simone; Murray, Greg

    2018-06-01

    Quality of life (QoL) is increasingly a target of interventions for bipolar disorders (BD). While the subjective experience of consumers is often elevated as central to the construct of QoL in BD, limited investigation in this area means subjective QoL remains poorly understood. The present qualitative study seeks to address this by investigating how people with BD appraise the quality of their lives in the context of a QoL self-management intervention. Semi-structured interviews were conducted with 43 individuals who had participated in a self-management intervention for improving QoL in BD. Individuals were questioned about experiences of the intervention and perceptions of their QoL. Thematic analysis was used to explore participants' appraisal of their QoL. An overarching theme concerned the intrinsic relativity of subjective QoL: individuals located QoL as relative to self, others and possible futures. Incorporating illness-related reference points for QoL ('given my circumstances…') was associated with perceptions of improved QoL. Deliberately modifying reference points for QoL was perceived as self-compassionate. The present study generates novel hypotheses about how individuals with BD make sense of their QoL. Data suggest that individuals located their QoL relative to a variety of reference points, use of which was flexible. In accord with gap theories of QoL, individuals experienced acceptance of illness impacts as improving subjective sense of QoL. Rather than 'settling for' a lower standard of QoL, individuals experienced these changes as adaptive and positive. Findings are discussed in relation to the measurement and amelioration of QoL in BD.

  18. Insulin resistance in obesity can be reliably identified from fasting plasma insulin.

    PubMed

    ter Horst, K W; Gilijamse, P W; Koopman, K E; de Weijer, B A; Brands, M; Kootte, R S; Romijn, J A; Ackermans, M T; Nieuwdorp, M; Soeters, M R; Serlie, M J

    2015-12-01

    Insulin resistance is the major contributor to cardiometabolic complications of obesity. We aimed to (1) establish cutoff points for insulin resistance from euglycemic hyperinsulinemic clamps (EHCs), (2) identify insulin-resistant obese subjects and (3) predict insulin resistance from routinely measured variables. We assembled data from non-obese (n=112) and obese (n=100) men who underwent two-step EHCs using [6,6-(2)H2]glucose as tracer (insulin infusion dose 20 and 60 mU m(-2) min(-1), respectively). Reference ranges for hepatic and peripheral insulin sensitivity were calculated from healthy non-obese men. Based on these reference values, obese men with preserved insulin sensitivity or insulin resistance were identified. Cutoff points for insulin-mediated suppression of endogenous glucose production (EGP) and insulin-stimulated glucose disappearance rate (Rd) were 46.5% and 37.3 μmol kg(-)(1) min(-)(1), respectively. Most obese men (78%) had EGP suppression within the reference range, whereas only 12% of obese men had Rd within the reference range. Obese men with Rd <37.3 μmol kg(-1) min(-1) did not differ from insulin-sensitive obese men in age, body mass index (BMI), body composition, fasting glucose or cholesterol, but did have higher fasting insulin (110±49 vs 63±29 pmol l(-1), P<0.001) and homeostasis model assessment of insulin resistance (HOMA-IR) (4.5±2.2 vs 2.7±1.4, P=0.004). Insulin-resistant obese men could be identified with good sensitivity (80%) and specificity (75%) from fasting insulin >74 pmol l(-1). Most obese men have hepatic insulin sensitivity within the range of non-obese controls, but below-normal peripheral insulin sensitivity, that is, insulin resistance. Fasting insulin (>74 pmol l(-1) with current insulin immunoassay) may be used for identification of insulin-resistant (or metabolically unhealthy) obese men in research and clinical settings.

  19. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Flach, G. P.; Whiteside, T. S.

    The E-Area Vadose Zone Monitoring System (VZMS) includes lysimeter sampling points at many locations alongside and angling beneath the Engineered Trench #1 (ET1) disposal unit footprint. The sampling points for ET1 were selected for this study because collectively they showed consistently higher tritium (H-3) concentrations than lysimeters associated with other trench units. The VZMS tritium dataset for ET1 from 2001 through 2015 comprises concentrations at or near background levels at approximately half of locations through time, concentrations up to about 600 pCi/mL at a few locations, and concentrations at two locations that have exceeded 1000 pCi/mL. The highest three valuesmore » through 2015 were 6472 pCi/mL in 2014 and 4533 pCi/mL in 2013 at location VL-17, and 3152 pCi/mL in 2007 at location VL-15. As a point of reference, the drinking water standard for tritium and a DOE Order 435.1 performance objective in the saturated zone at the distant 100-meter facility perimeter is 20 pCi/mL. The purpose of this study is to assess whether these elevated concentrations are indicative of a general trend that could challenge 2008 E-Area Performance Assessment (PA) conclusions, or are isolated perturbations that when considered in the context of an entire disposal unit would support PA conclusions.« less

  20. Assessing the performance of handheld glucose testing for critical care.

    PubMed

    Kost, Gerald J; Tran, Nam K; Louie, Richard F; Gentile, Nicole L; Abad, Victor J

    2008-12-01

    We assessed the performance of a point-of-care (POC) glucose meter system (GMS) with multitasking test strip by using the locally-smoothed (LS) median absolute difference (MAD) curve method in conjunction with a modified Bland-Altman difference plot and superimposed International Organization for Standardization (ISO) 15197 tolerance bands. We analyzed performance for tight glycemic control (TGC). A modified glucose oxidase enzyme with a multilayer-gold, multielectrode, four-well test strip (StatStriptrade mark, NOVA Biomedical, Waltham, MA) was used. There was no test strip calibration code. Pragmatic comparison was done of GMS results versus paired plasma glucose measurements from chemistry analyzers in clinical laboratories. Venous samples (n = 1,703) were analyzed at 35 hospitals that used 20 types of chemistry analyzers. Erroneous results were identified using the Bland-Altman plot and ISO 15197 criteria. Discrepant values were analyzed for the TGC interval of 80-110 mg/dL. The GMS met ISO 15197 guidelines; 98.6% (410 of 416) of observations were within tolerance for glucose <75 mg/dL, and for > or =75 mg/dL, 100% were within tolerance. Paired differences (handheld minus reference) averaged -2.2 (SD 9.8) mg/dL; the median was -1 (range, -96 to 45) mg/dL. LS MAD curve analysis revealed satisfactory performance below 186 mg/dL; above 186 mg/dL, the recommended error tolerance limit (5 mg/dL) was not met. No discrepant values appeared. All points fell in Clarke Error Grid zone A. Linear regression showed y = 1.018x - 0.716 mg/dL, and r2 = 0.995. LS MAD curves draw on human ability to discriminate performance visually. LS MAD curve and ISO 15197 performance were acceptable for TGC. POC and reference glucose calibration should be harmonized and standardized.

  1. Comparison between the triglycerides standardization of routine methods used in Japan and the chromotropic acid reference measurement procedure used by the CDC Lipid Standardization Programme.

    PubMed

    Nakamura, Masakazu; Iso, Hiroyasu; Kitamura, Akihiko; Imano, Hironori; Noda, Hiroyuki; Kiyama, Masahiko; Sato, Shinichi; Yamagishi, Kazumasa; Nishimura, Kunihiro; Nakai, Michikazu; Vesper, Hubert W; Teramoto, Tamio; Miyamoto, Yoshihiro

    2016-11-01

    Background The US Centers for Disease Control and Prevention ensured adequate performance of the routine triglycerides methods used in Japan by a chromotropic acid reference measurement procedure used by the Centers for Disease Control and Prevention lipid standardization programme as a reference point. We examined standardized data to clarify the performance of routine triglycerides methods. Methods The two routine triglycerides methods were the fluorometric method of Kessler and Lederer and the enzymatic method. The methods were standardized using 495 Centers for Disease Control and Prevention reference pools with 98 different concentrations ranging between 0.37 and 5.15 mmol/L in 141 survey runs. The triglycerides criteria for laboratories which perform triglycerides analyses are used: accuracy, as bias ≤5% from the Centers for Disease Control and Prevention reference value and precision, as measured by CV, ≤5%. Results The correlation of the bias of both methods to the Centers for Disease Control and Prevention reference method was: y (%bias) = 0.516 × (Centers for Disease Control and Prevention reference value) -1.292 ( n = 495, R 2  = 0.018). Triglycerides bias at medical decision points of 1.13, 1.69 and 2.26 mmol/L was -0.71%, -0.42% and -0.13%, respectively. For the combined precision, the equation y (CV) = -0.398 × (triglycerides value) + 1.797 ( n = 495, R 2  = 0.081) was used. Precision was 1.35%, 1.12% and 0.90%, respectively. It was shown that triglycerides measurements at Osaka were stable for 36 years. Conclusions The epidemiologic laboratory in Japan met acceptable accuracy goals for 88.7% of all samples, and met acceptable precision goals for 97.8% of all samples measured through the Centers for Disease Control and Prevention lipid standardization programme and demonstrated stable results for an extended period of time.

  2. Comparison between the triglycerides standardization of routine methods used in Japan and the chromotropic acid reference measurement procedure used by the CDC Lipid Standardization Programme

    PubMed Central

    Nakamura, Masakazu; Iso, Hiroyasu; Kitamura, Akihiko; Imano, Hironori; Noda, Hiroyuki; Kiyama, Masahiko; Sato, Shinichi; Yamagishi, Kazumasa; Nishimura, Kunihiro; Nakai, Michikazu; Vesper, Hubert W; Teramoto, Tamio; Miyamoto, Yoshihiro

    2017-01-01

    Background The US Centers for Disease Control and Prevention ensured adequate performance of the routine triglycerides methods used in Japan by a chromotropic acid reference measurement procedure used by the Centers for Disease Control and Prevention lipid standardization programme as a reference point. We examined standardized data to clarify the performance of routine triglycerides methods. Methods The two routine triglycerides methods were the fluorometric method of Kessler and Lederer and the enzymatic method. The methods were standardized using 495 Centers for Disease Control and Prevention reference pools with 98 different concentrations ranging between 0.37 and 5.15 mmol/L in 141 survey runs. The triglycerides criteria for laboratories which perform triglycerides analyses are used: accuracy, as bias ≤5% from the Centers for Disease Control and Prevention reference value and precision, as measured by CV, ≤5%. Results The correlation of the bias of both methods to the Centers for Disease Control and Prevention reference method was: y (%bias) = 0.516 × (Centers for Disease Control and Prevention reference value) −1.292 (n = 495, R2 = 0.018). Triglycerides bias at medical decision points of 1.13, 1.69 and 2.26 mmol/L was −0.71%, −0.42% and −0.13%, respectively. For the combined precision, the equation y (CV) = −0.398 × (triglycerides value) + 1.797 (n = 495, R2 = 0.081) was used. Precision was 1.35%, 1.12% and 0.90%, respectively. It was shown that triglycerides measurements at Osaka were stable for 36 years. Conclusions The epidemiologic laboratory in Japan met acceptable accuracy goals for 88.7% of all samples, and met acceptable precision goals for 97.8% of all samples measured through the Centers for Disease Control and Prevention lipid standardization programme and demonstrated stable results for an extended period of time. PMID:26680645

  3. Influence of time point of calibration on accuracy of continuous glucose monitoring in individuals with type 1 diabetes.

    PubMed

    Zueger, Thomas; Diem, Peter; Mougiakakou, Stavroula; Stettler, Christoph

    2012-07-01

    Data on the influence of calibration on accuracy of continuous glucose monitoring (CGM) are scarce. The aim of the present study was to investigate whether the time point of calibration has an influence on sensor accuracy and whether this effect differs according to glycemic level. Two CGM sensors were inserted simultaneously in the abdomen on either side of 20 individuals with type 1 diabetes. One sensor was calibrated predominantly using preprandial glucose (calibration(PRE)). The other sensor was calibrated predominantly using postprandial glucose (calibration(POST)). At minimum three additional glucose values per day were obtained for analysis of accuracy. Sensor readings were divided into four categories according to the glycemic range of the reference values (low, ≤4 mmol/L; euglycemic, 4.1-7 mmol/L; hyperglycemic I, 7.1-14 mmol/L; and hyperglycemic II, >14 mmol/L). The overall mean±SEM absolute relative difference (MARD) between capillary reference values and sensor readings was 18.3±0.8% for calibration(PRE) and 21.9±1.2% for calibration(POST) (P<0.001). MARD according to glycemic range was 47.4±6.5% (low), 17.4±1.3% (euglycemic), 15.0±0.8% (hyperglycemic I), and 17.7±1.9% (hyperglycemic II) for calibration(PRE) and 67.5±9.5% (low), 24.2±1.8% (euglycemic), 15.5±0.9% (hyperglycemic I), and 15.3±1.9% (hyperglycemic II) for calibration(POST). In the low and euglycemic ranges MARD was significantly lower in calibration(PRE) compared with calibration(POST) (P=0.007 and P<0.001, respectively). Sensor calibration predominantly based on preprandial glucose resulted in a significantly higher overall sensor accuracy compared with a predominantly postprandial calibration. The difference was most pronounced in the hypo- and euglycemic reference range, whereas both calibration patterns were comparable in the hyperglycemic range.

  4. Monitoring the freely dissolved concentrations of polycyclic aromatic hydrocarbons (PAH) and alkylphenols (AP) around a Norwegian oil platform by holistic passive sampling.

    PubMed

    Harman, Christopher; Thomas, Kevin V; Tollefsen, Knut Erik; Meier, Sonnich; Bøyum, Olav; Grung, Merete

    2009-11-01

    In order to assess the environmental impact of aquatic discharges from the offshore oil industry, polar organic chemical integrative samplers (POCIS) and semipermeable membrane devices (SPMDs) were deployed around an oil platform and at reference locations in the North Sea. Exposure to polycyclic aromatic hydrocarbons (PAH) and alkylated phenols (AP) was determined from passive sampler accumulations using an empirical uptake model, the dissipation of performance reference compounds and adjusted laboratory derived sampling rates. Exposure was relatively similar within 1-2 km of the discharge point, with levels dominated by short chained C1-C3 AP isomers (19-51 ngL(-1)) and alkylated naphthalenes, phenanthrenes and dibenzothiophenes (NPD, 29-45 ngL(-1)). Exposure stations showed significant differences to reference sites for NPD, but not always for more hydrophobic PAH. These concentrations are several orders of magnitude lower than those reported to give both acute and sub-lethal effects, although their long term consequences are unknown.

  5. Modeling the Global Coronal Field with Simulated Synoptic Magnetograms from Earth and the Lagrange Points L3, L4, and L5

    NASA Astrophysics Data System (ADS)

    Petrie, Gordon; Pevtsov, Alexei; Schwarz, Andrew; DeRosa, Marc

    2018-06-01

    The solar photospheric magnetic flux distribution is key to structuring the global solar corona and heliosphere. Regular full-disk photospheric magnetogram data are therefore essential to our ability to model and forecast heliospheric phenomena such as space weather. However, our spatio-temporal coverage of the photospheric field is currently limited by our single vantage point at/near Earth. In particular, the polar fields play a leading role in structuring the large-scale corona and heliosphere, but each pole is unobservable for {>} 6 months per year. Here we model the possible effect of full-disk magnetogram data from the Lagrange points L4 and L5, each extending longitude coverage by 60°. Adding data also from the more distant point L3 extends the longitudinal coverage much further. The additional vantage points also improve the visibility of the globally influential polar fields. Using a flux-transport model for the solar photospheric field, we model full-disk observations from Earth/L1, L3, L4, and L5 over a solar cycle, construct synoptic maps using a novel weighting scheme adapted for merging magnetogram data from multiple viewpoints, and compute potential-field models for the global coronal field. Each additional viewpoint brings the maps and models into closer agreement with the reference field from the flux-transport simulation, with particular improvement at polar latitudes, the main source of the fast solar wind.

  6. Particulate Meso-scale Mechanics Diagnostics: Magnetic Sensors for Dynamic State Orientation

    DTIC Science & Technology

    2013-12-01

    Research Laboratory for giving this opportunity to work at the Eglin AFB, FL. REFERENCES 1. Brian D. Reding , “Development of Particulate Materials...Measurements," Sandia Report, 1984. 15. I.N. Tansel, B. Reding , W. L. Cooper, “Lagrangian Point State Estimation with Optimized, Redundant Induction Coil

  7. Precise aircraft single-point positioning using GPS post-mission orbits and satellite clock corrections

    NASA Astrophysics Data System (ADS)

    Lachapelle, G.; Cannon, M. E.; Qiu, W.; Varner, C.

    1996-09-01

    Aircraft single point position accuracy is assessed through a comparison of the single point coordinates with corresponding DGPS-derived coordinates. The platform utilized for this evaluation is a Naval Air Warfare Center P-3 Orion aircraft. Data was collected over a period of about 40 hours, spread over six days, off Florida's East Coast in July 94, using DGPS reference stations in Jacksonville, FL, and Warminster, PA. The analysis of results shows that the consistency between aircraft single point and DGPS coordinates obtained in single point positioning mode and DGPS mode is about 1 m (rms) in latitude and longitude, and 2 m (rms) in height, with instantaneous errors of up to a few metres due to the effect of the ionosphere on the single point L1 solutions.

  8. Ada Compiler Validation Summary Report: Certificate Number 910705S1. 11192 InterAct Corporation InterAct Ada Mips Cross-Compiler System, Release 2.0 MicroVAX 3100 Cluster = Lockheed Sanders STAR MVP R3000/R3010 board (Bare Machine).

    DTIC Science & Technology

    1991-07-31

    have floating-point type declarations requiring more digits than SYSTEM.MAXDIGITS: C24113L..Y (14 tests) C35705L..Y (14 tests) C357C6L..Y (14 tests...2_147_483_648..2_147_483_647; type FLOAT is digits 6 range -2#l.0#E128.. 2#0.IIIIIIIIIIIIIIIIIIIII#El28; type LONGFLOAT is digits 15 range -2#l.0#EI024.. 2...are instan- tated into libary packages or subprograms.) F-14 Appendix F of the Ada Reference Manual F.8.1. Address Clauses for Variables Address

  9. Lagrange Point Missions: the Key to Next-Generation Integrated Earth Observations. DSCOVR Innovation

    NASA Astrophysics Data System (ADS)

    Valero, F. P. J.

    2016-12-01

    From L-1 DSCOVR is capable of new, unique observations potentially conducive to a deeper scientific understanding of the Earth sciences. At L-1 and L-2 the net gravitational pull of the Earth and Sun equals the centripetal force required to orbit the Sun with the same period as the Earth. Satellites at or near L-1 and L-2 keep the same position relative to the Sun and the Earth. DSCOVR does not orbit the Earth but the Sun in synchronism with Earth, acts like a planetoid (orbits the Sun in the ecliptic plane) while acquiring integrated plus spatially and time resolved scientific data as Earth rotates around its axis. Because of the planet's axial tilt relative to the ecliptic plane, the Polar Regions are visible during local summer from L-1 and local winter from L-2 (Fig. 1). DSCOVR's synoptic and continuous observations solve most of the temporal and spatial limitations associated with low Earth (LEO) and Geostationary (GEO) orbits. Two observatories, one at L-1 (daytime) and one at L-2 (nighttime), would acquire minute-by-minute climate quality data for essentially every point on Earth. The integration of L-1, L-2, LEO, and GEO satellites plus the Moon offers new scientific tools and enriched data sets for Earth sciences. Lagrange points observatories are key to next-generation integrated Earth observations. For example, DSCOVR at L-1 views the Earth plus the Moon (a reference) and simultaneously, at one time or another, all LEO and GEO satellites. The L-1 and L-2 satellites would be the link between the Moon, LEO and GEO satellites while providing the data needed to build an integrated Earth observational system. The above properties are the bases for DSCOVR's innovation and scientific approach that systematically observes climate drivers (radiation, aerosols, ozone, clouds, water vapor, vegetation) from L-1 in a way not possible but synergistic with other satellites. Next step: more capable L-1 plus L-2 satellites. The way of the future.

  10. Proposed biosimilar pegfilgrastim (LA-EP2006) compared with reference pegfilgrastim in Asian patients with breast cancer: an exploratory comparison from two Phase III trials.

    PubMed

    Harbeck, Nadia; Gascon, Pere; Jones, Clyde M; Nixon, Allen; Krendyukov, Andriy; Nakov, Roumen; Li, Yuhan; Blackwell, Kimberly

    2017-07-01

    This is a pooled subgroup analysis of Asian patients enrolled in two Phase III confirmatory studies comparing proposed biosimilar LA-EP2006 with reference pegfilgrastim in women receiving chemotherapy for breast cancer. Women were randomized to LA-EP2006 (n = 90) or reference (n = 84) pegfilgrastim (Neulasta ® , Amgen, Inc., CA, USA) for ≤6 cycles of TAC chemotherapy. Primary end point was duration of severe neutropenia during Cycle 1 (number of consecutive days with absolute neutrophil count <0.5 × 10 9 /l) with equivalence confirmed if 95% CIs were within a ±1-day margin. Mean duration of severe neutropenia (days) in Cycle 1 was 1.36 ± 0.98 (LA-EP2006) versus 1.35 ± 1.06 (reference) (difference 0.01 days; 95% CI: -0.30-0.32, indicating equivalence). LA-EP2006 showed similar clinical efficacy and safety compared with reference pegfilgrastim.

  11. Relative Gains, Losses, and Reference Points in Probabilistic Choice in Rats

    PubMed Central

    Marshall, Andrew T.; Kirkpatrick, Kimberly

    2015-01-01

    Theoretical reference points have been proposed to differentiate probabilistic gains from probabilistic losses in humans, but such a phenomenon in non-human animals has yet to be thoroughly elucidated. Three experiments evaluated the effect of reward magnitude on probabilistic choice in rats, seeking to determine reference point use by examining the effect of previous outcome magnitude(s) on subsequent choice behavior. Rats were trained to choose between an outcome that always delivered reward (low-uncertainty choice) and one that probabilistically delivered reward (high-uncertainty). The probability of high-uncertainty outcome receipt and the magnitudes of low-uncertainty and high-uncertainty outcomes were manipulated within and between experiments. Both the low- and high-uncertainty outcomes involved variable reward magnitudes, so that either a smaller or larger magnitude was probabilistically delivered, as well as reward omission following high-uncertainty choices. In Experiments 1 and 2, the between groups factor was the magnitude of the high-uncertainty-smaller (H-S) and high-uncertainty-larger (H-L) outcome, respectively. The H-S magnitude manipulation differentiated the groups, while the H-L magnitude manipulation did not. Experiment 3 showed that manipulating the probability of differential losses as well as the expected value of the low-uncertainty choice produced systematic effects on choice behavior. The results suggest that the reference point for probabilistic gains and losses was the expected value of the low-uncertainty choice. Current theories of probabilistic choice behavior have difficulty accounting for the present results, so an integrated theoretical framework is proposed. Overall, the present results have implications for understanding individual differences and corresponding underlying mechanisms of probabilistic choice behavior. PMID:25658448

  12. Referent Salience Affects Second Language Article Use

    ERIC Educational Resources Information Center

    Trenkic, Danijela; Pongpairoj, Nattama

    2013-01-01

    The effect of referent salience on second language (L2) article production in real time was explored. Thai (-articles) and French (+articles) learners of English described dynamic events involving two referents, one visually cued to be more salient at the point of utterance formulation. Definiteness marking was made communicatively redundant with…

  13. A green and efficient procedure for the preconcentration and determination of cadmium, nickel and zinc from freshwater, hemodialysis solutions and tuna fish samples by cloud point extraction and flame atomic absorption spectrometry.

    PubMed

    Galbeiro, Rafaela; Garcia, Samara; Gaubeur, Ivanise

    2014-04-01

    Cloud point extraction (CPE) was used to simultaneously preconcentrate trace-level cadmium, nickel and zinc for determination by flame atomic absorption spectrometry (FAAS). 1-(2-Pyridilazo)-2-naphthol (PAN) was used as a complexing agent, and the metal complexes were extracted from the aqueous phase by the surfactant Triton X-114 ((1,1,3,3-tetramethylbutyl)phenyl-polyethylene glycol). Under optimized complexation and extraction conditions, the limits of detection were 0.37μgL(-1) (Cd), 2.6μgL(-1) (Ni) and 2.3μgL(-1) (Zn). This extraction was quantitative with a preconcentration factor of 30 and enrichment factor estimated to be 42, 40 and 43, respectively. The method was applied to different complex samples, and the accuracy was evaluated by analyzing a water standard reference material (NIST SRM 1643e), yielding results in agreement with the certified values. Copyright © 2013 Elsevier GmbH. All rights reserved.

  14. A new cloud point extraction procedure for determination of inorganic antimony species in beverages and biological samples by flame atomic absorption spectrometry.

    PubMed

    Altunay, Nail; Gürkan, Ramazan

    2015-05-15

    A new cloud-point extraction (CPE) for the determination of antimony species in biological and beverages samples has been established with flame atomic absorption spectrometry (FAAS). The method is based on the fact that formation of the competitive ion-pairing complex of Sb(III) and Sb(V) with Victoria Pure Blue BO (VPB(+)) at pH 10. The antimony species were individually detected by FAAS. Under the optimized conditions, the calibration range for Sb(V) is 1-250 μg L(-1) with a detection limit of 0.25 μg L(-1) and sensitive enhancement factor of 76.3 while the calibration range for Sb(III) is 10-400 μg L(-1) with a detection limit of 5.15 μg L(-1) and sensitive enhancement factor of 48.3. The precision as a relative standard deviation is in range of 0.24-2.35%. The method was successfully applied to the speciative determination of antimony species in the samples. The validation was verified by analysis of certified reference materials (CRMs). Copyright © 2014 Elsevier Ltd. All rights reserved.

  15. Blood patch rates after lumbar puncture with Whitacre versus Quincke 22- and 20-gauge spinal needles.

    PubMed

    Hatfield, Malcolm K; Handrich, Stephen J; Willis, Jeffrey A; Beres, Robert A; Zaleski, George X

    2008-06-01

    The objective of our study was to compare the incidence of blood patch as the best objective indicator of postdural puncture headache after elective fluoroscopic lumbar puncture with the use of a 22-gauge Whitacre (pencil point) needle versus standard 22- and 20-gauge Quincke (bevel-tip) needles and to determine the best level of puncture. The records of 724 consecutive patients who were referred to St. Mary's Medical Center department of radiology for fluoroscopic lumbar puncture from January 2003 through April 2007 were retrospectively reviewed. Emergency requests (191) were discarded along with those for patients with clinical signs of pseudotumor cerebri (21), normal pressure hydrocephalus (3), and failed attempts (4). The collective total was 505 elective lumbar punctures. The blood patch rate for the 22-gauge Whitacre needle was 4.2%. The result for the 22-gauge Quincke point needle was 15.1% whereas that for the 20-gauge Quincke point needle was 29.6%. In addition, the level of puncture showed a blood patch rate that increased as the level of lumbar puncture lowered. The highest level of lumbar puncture was L1-L2 with the lowest recorded level being L5-S1. The Whitacre needle is associated with a significantly lower incidence of blood patch rate after lumbar puncture. The highest level of puncture (L1-L2) also provides the lowest level of blood patch rate.

  16. Comparison of three point-of-care blood glucose meters for use in adult and juvenile alpacas.

    PubMed

    Tennent-Brown, Brett S; Koenig, Amie; Williamson, Lisa H; Boston, Raymond C

    2011-08-01

    To compare the performance of 3 point-of-care glucose meters in adult and juvenile alpacas with that of a laboratory-based analyzer. Evaluation study. 35 adult alpacas and 21 juvenile alpacas. Whole blood samples obtained via jugular venipuncture were tested with all 3 point-of-care glucose meters; plasma samples were also tested with 1 of those meters. Glucose concentrations determined by use of the point-of-care meters were compared with results from the laboratory-based analyzer. Plasma glucose concentrations determined by use of the laboratory-based analyzer ranged from 36 to 693 mg/dL. Over the entire range of glucose concentrations tested, the Lin concordance correlation coefficient (agreement) was significant and excellent for all comparisons. Concordance decreased for 1 glucometer when testing whole blood samples over a narrower range of glucose concentrations (50 to 200 mg/dL). Bias was typically small (< 10 mg/dL) for 3 of the 4 comparisons but considerable for 1 meter with the use of whole blood. The limits of agreement were wide for all comparisons over the entire range of glucose concentrations tested but decreased to within acceptable limits when the narrower glucose range (50 to 200 mg/dL) was analyzed for 3 of the comparisons. For samples with a PCV < 25%, bias and the limits of agreement were greater for one of the meters tested. Discrepancies between point-of-care glucose meters and reference techniques can be considerable in alpacas, emphasizing the importance of assessing individual meter performance in a target population.

  17. Sources of endocrine-disrupting compounds in North Carolina waterways: a geographic information systems approach

    USGS Publications Warehouse

    Sackett, Dana K.; Pow, Crystal Lee; Rubino, Matthew J.; Aday, D.D.; Cope, W. Gregory; Kullman, Seth W.; Rice, J.A.; Kwak, Thomas J.; Law, L.M.

    2015-01-01

    The presence of endocrine-disrupting compounds (EDCs), particularly estrogenic compounds, in the environment has drawn public attention across the globe, yet a clear understanding of the extent and distribution of estrogenic EDCs in surface waters and their relationship to potential sources is lacking. The objective of the present study was to identify and examine the potential input of estrogenic EDC sources in North Carolina water bodies using a geographic information system (GIS) mapping and analysis approach. Existing data from state and federal agencies were used to create point and nonpoint source maps depicting the cumulative contribution of potential sources of estrogenic EDCs to North Carolina surface waters. Water was collected from 33 sites (12 associated with potential point sources, 12 associated with potential nonpoint sources, and 9 reference), to validate the predictive results of the GIS analysis. Estrogenicity (measured as 17β-estradiol equivalence) ranged from 0.06 ng/L to 56.9 ng/L. However, the majority of sites (88%) had water 17β-estradiol concentrations below 1 ng/L. Sites associated with point and nonpoint sources had significantly higher 17β-estradiol levels than reference sites. The results suggested that water 17β-estradiol was reflective of GIS predictions, confirming the relevance of landscape-level influences on water quality and validating the GIS approach to characterize such relationships.

  18. Sources of endocrine-disrupting compounds in North Carolina waterways: a geographic information systems approach.

    PubMed

    Sackett, Dana K; Pow, Crystal Lee; Rubino, Matthew J; Aday, D Derek; Cope, W Gregory; Kullman, Seth; Rice, James A; Kwak, Thomas J; Law, Mac

    2015-02-01

    The presence of endocrine-disrupting compounds (EDCs), particularly estrogenic compounds, in the environment has drawn public attention across the globe, yet a clear understanding of the extent and distribution of estrogenic EDCs in surface waters and their relationship to potential sources is lacking. The objective of the present study was to identify and examine the potential input of estrogenic EDC sources in North Carolina water bodies using a geographic information system (GIS) mapping and analysis approach. Existing data from state and federal agencies were used to create point and nonpoint source maps depicting the cumulative contribution of potential sources of estrogenic EDCs to North Carolina surface waters. Water was collected from 33 sites (12 associated with potential point sources, 12 associated with potential nonpoint sources, and 9 reference), to validate the predictive results of the GIS analysis. Estrogenicity (measured as 17β-estradiol equivalence) ranged from 0.06 ng/L to 56.9 ng/L. However, the majority of sites (88%) had water 17β-estradiol concentrations below 1 ng/L. Sites associated with point and nonpoint sources had significantly higher 17β-estradiol levels than reference sites. The results suggested that water 17β-estradiol was reflective of GIS predictions, confirming the relevance of landscape-level influences on water quality and validating the GIS approach to characterize such relationships. © 2014 SETAC.

  19. Aquatic biomonitoring of Giardia cysts and Cryptosporidium oocysts in peninsular Malaysia.

    PubMed

    Lee, Soo Ching; Ngui, Romano; Tan, Tiong Kai; Roslan, Muhammad Aidil; Ithoi, Init; Lim, Yvonne A L

    2014-01-01

    An aquatic biomonitoring of Giardia cysts and Cryptosporidium oocysts in river water corresponding to five villages situated in three states in peninsular Malaysia was determined. There were 51.3% (20/39) and 23.1% (9/39) samples positive for Giardia and Cryptosporidium (oo)cysts, respectively. Overall mean concentration between villages for Giardia cysts ranged from 0.10 to 25.80 cysts/l whilst Cryptosporidium oocysts ranged from 0.10 to 0.90 oocysts/l. Detailed results of the river samples from five villages indicated that Kuala Pangsun 100% (9/9), Kemensah 77.8% (7/9), Pos Piah 33.3% (3/9) and Paya Lebar 33.3% (1/3) were contaminated with Giardia cysts whilst Cryptosporidium (oo)cysts were only detected in Kemensah (100 %; 9/9) and Kuala Pangsun (66.6%; 6/9). However, the water samples from Bentong were all negative for these waterborne parasites. Samples were collected from lower point, midpoint and upper point. Midpoint refers to the section of the river where the studied communities are highly populated. Meanwhile, the position of the lower point is at least 2 km southward of the midpoint and upper point is at least 2 km northward of the midpoint. The highest mean concentration for (oo)cysts was found at the lower points [3.15 ± 6.09 (oo)cysts/l], followed by midpoints [0.66 ± 1.10 (oo)cysts/l] and upper points [0.66 ± 0.92 (oo)cysts/l]. The mean concentration of Giardia cysts was highest at Kuala Pangsun (i.e. 5.97 ± 7.0 cysts/l), followed by Kemensah (0.83 ± 0.81 cysts/l), Pos Piah (0.20 ± 0.35 cysts/l) and Paya Lebar (0.10 ± 0.19 cysts/l). On the other hand, the mean concentration of Cryptosporidium oocysts was higher at Kemensah (0.31 ± 0.19 cysts/l) compared to Kuala Pangsun (0.03 ± 0.03cysts/l). All the physical and chemical parameters did not show significant correlation with both protozoa. In future, viability status and molecular characterisation of Giardia and Cryptosporidium should be applied to identify species and genotypes/subgenotypes for better understanding of the epidemiology of these waterborne parasites.

  20. Reliability of the Lactate Scout point-of-care instrument for the determination of blood L-lactate concentration in sheep.

    PubMed

    Kaynar, Ozgur; Karapinar, Tolga; Hayirli, Armagan; Baydar, Ersoy

    2015-12-01

    Data on accuracy and precision of the Lactate Scout point-of-care (POC) analyzer in ovine medicine are lacking. The purpose of the study was to assess the reliability of the Lactate Scout in sheep. Fifty-seven sheep at varying ages with various diseases were included. Blood lactate concentration in samples collected from the jugular vein was measured immediately on the Lactate Scout. Plasma L-lactate concentration was measured by the Cobas autoanalyzer as the reference method. Data were subjected to Student's t-test, Passing-Bablok regression, and Bland-Altman plot analyses for comparison and assessment of accuracy, precision, and reliability. Plasma l-lactate concentration was consistently lower than blood L-lactate concentration (3.06 ± 0.24 vs 3.3 ± 0.3 mmol/L, P < .0001). There was a positive correlation between plasma and blood L-lactate concentrations (r = .98, P < .0001). The Lactate Scout had 99% accuracy and 98% precision with the reference method. Blood (Y) and plasma (X) L-lactate concentrations were fitted to Y = 0.28 + 1.00 · X, with a residual standard deviation of 0.31 and a negligible deviation from the identity line (P = .93). The bias was fitted to Y = 0.10 + 0.05 · X, with Sy.x of 0.44 (P < .07). The Lactate Scout has high accuracy and precision, with a negligible bias. It is a reliable POC analyzer to assess L-lactate concentration in ovine medicine. © 2015 American Society for Veterinary Clinical Pathology.

  1. Numerical simulation of the effect of groundwater salinity on artificial freezing wall in coastal area

    NASA Astrophysics Data System (ADS)

    Hu, Rui; Liu, Quan

    2017-04-01

    During the engineering projects with artificial ground freezing (AFG) techniques in coastal area, the freezing effect is affected by groundwater salinity. Based on the theories of artificially frozen soil and heat transfer in porous material, and with the assumption that only the variations of total dissolved solids (TDS) impact on freezing point and thermal conductivity, a numerical model of an AFG project in a saline aquifer was established and validated by comparing the simulated temperature field with the calculated temperature based on the analytic solution of rupak (reference) for single-pipe freezing temperature field T. The formation and development of freezing wall were simulated with various TDS. The results showed that the variety of TDS caused the larger temperature difference near the frozen front. With increasing TDS in the saline aquifer (1 35g/L), the average thickness of freezing wall decreased linearly and the total formation time of the freezing wall increased linearly. Compared with of the scenario of fresh-water (<1g/L), the average thickness of frozen wall decreased by 6% and the total formation time of the freezing wall increased by 8% with each increasing TDS of 7g/L. Key words: total dissolved solids, freezing point, thermal conductivity, freezing wall, numerical simulation Reference D.J.Pringel, H.Eicken, H.J.Trodahl, etc. Thermal conductivity of landfast Antarctic and Arctic sea ice[J]. Journal of Geophysical Research, 2007, 112: 1-13. Lukas U.Arenson, Dave C.Sego. The effect of salinity on the freezing of coarse- grained sand[J]. Canadian Geotechnical Journal, 2006, 43: 325-337. Hui Bing, Wei Ma. Laboratory investigation of the freezing point of saline soil[J]. Cold Regions Science and Technology, 2011, 67: 79-88.

  2. Non-chromatographic speciation of chromium at sub-ppb levels using cloud point extraction in the presence of unmodified silver nanoparticles.

    PubMed

    López-García, Ignacio; Vicente-Martínez, Yesica; Hernández-Córdoba, Manuel

    2015-01-01

    The cloud point extraction (CPE) of silver nanoparticles (AgNPs) by Triton X-114 allows chromium (III) ions to be transferred to the surfactant-rich phase, where they can be measured by electrothermal atomic absorption spectrometry. Using 20 mL sample and 50 μL Triton X-114 (30% w/v), the enrichment factor was 1150, and calibration graphs were obtained in the 5-100 ng L(-1) chromium range in the presence of 5 µg L(-1) AgNPs. Speciation of trivalent and hexavalent chromium was achieved by carrying out two CPE experiments, one of them in the presence of ethylenediaminetetraacetate. While in the first experiment, in absence of the complexing agent, the concentration of total chromium was obtained, the analytical signal measured in the presence of this chemical allowed the chromium (VI) concentration to be measured, being that of chromium (III) calculated by difference. The reliability of the procedure was verified by using three standard reference materials before applying to water, beer and wine samples. Copyright © 2014 Elsevier B.V. All rights reserved.

  3. Second Language Vocabulary Acquisition from Language Input and from Form-Focused Activities

    ERIC Educational Resources Information Center

    Laufer, Batia

    2009-01-01

    Interest in L2 vocabulary learning and teaching started long before the nineteen-eighties (for references to earlier studies, see Rob Waring's database http://www1.harenet.ne.jp/~waring/vocab/vocrefs/vocref.html) but it declined with the advent of generative linguistics to the point of discrimination and neglect (Meara 1980). In 1986, I argued…

  4. Libration Point Navigation Concepts Supporting Exploration Vision

    NASA Technical Reports Server (NTRS)

    Carpenter, J. Russell; Folta, David C.; Moreau, Michael C.; Gramling, Cheryl J.

    2004-01-01

    Farquhar described several libration point navigation concepts that would appear to support NASA s current exploration vision. One concept is a Lunar Relay Satellite operating in the vicinity of Earth-Moon L2, providing Earth-to-lunar far-side and long- range surface-to-surface navigation and communications capability. Reference [ 1] lists several advantages of such a system in comparison to a lunar orbiting relay satellite constellation. Among these are one or two vs. many satellites for coverage, simplified acquisition and tracking due to very low relative motion, much longer contact times, and simpler antenna pointing. An obvious additional advantage of such a system is that uninterrupted links to Earth avoid performing critical maneuvers "in the blind." Another concept described is the use of Earth-Moon L1 for lunar orbit rendezvous, rather than low lunar orbit as was done for Apollo. This rendezvous technique would avoid large plane change and high fuel cost associated with high latitude landing sites and long stay times. Earth-Moon L1 also offers unconstrained launch windows from the lunar surface. Farquhar claims this technique requires only slightly higher fuel cost than low lunar orbit rendezvous for short-stay equatorial landings. Farquhar also describes an Interplanetary Transportation System that would use libration points as terminals for an interplanetary shuttle. This approach would offer increased operational flexibility in terms of launch windows, rendezvous, aborts, etc. in comparison to elliptical orbit transfers. More recently, other works including Folta[3] and Howell[4] have shown that patching together unstable trajectories departing Earth-Moon libration points with stable trajectories approaching planetary libration points may also offer lower overall fuel costs than elliptical orbit transfers. Another concept Farquhar described was a Deep Space Relay at Earth-Moon IA and/or L5 that would serve as a high data rate optical navigation and communications relay satellite. The advantages in comparison to a geosynchronous relay are minimal Earth occultation, distance from large noise sources on Earth, easier pointing due to smaller relative velocity, and a large baseline for interferometry if both L4 and L5 are used.

  5. Dried blood spot analysis of creatinine with LC-MS/MS in addition to immunosuppressants analysis.

    PubMed

    Koster, Remco A; Greijdanus, Ben; Alffenaar, Jan-Willem C; Touw, Daan J

    2015-02-01

    In order to monitor creatinine levels or to adjust the dosage of renally excreted or nephrotoxic drugs, the analysis of creatinine in dried blood spots (DBS) could be a useful addition to DBS analysis. We developed a LC-MS/MS method for the analysis of creatinine in the same DBS extract that was used for the analysis of tacrolimus, sirolimus, everolimus, and cyclosporine A in transplant patients with the use of Whatman FTA DMPK-C cards. The method was validated using three different strategies: a seven-point calibration curve using the intercept of the calibration to correct for the natural presence of creatinine in reference samples, a one-point calibration curve at an extremely high concentration in order to diminish the contribution of the natural presence of creatinine, and the use of creatinine-[(2)H3] with an eight-point calibration curve. The validated range for creatinine was 120 to 480 μmol/L (seven-point calibration curve), 116 to 7000 μmol/L (1-point calibration curve), and 1.00 to 400.0 μmol/L for creatinine-[(2)H3] (eight-point calibration curve). The precision and accuracy results for all three validations showed a maximum CV of 14.0% and a maximum bias of -5.9%. Creatinine in DBS was found stable at ambient temperature and 32 °C for 1 week and at -20 °C for 29 weeks. Good correlations were observed between patient DBS samples and routine enzymatic plasma analysis and showed the capability of the DBS method to be used as an alternative for creatinine plasma measurement.

  6. Feasibility of triphasic CT with a modified two-point Patlak plot to determine spit kidney glomerular filtration rate in clinical practice.

    PubMed

    Zhang, Yu-Dong; Xue, Chen-Qi; Wu, Chen-Jiang; Tao, Jun; Zhou, Wan-Li; Shi, Hai-Bin

    2017-01-01

    To investigate whether triphasic CT with a simplified Patlak plot can be used in clinical practice for the estimate of split kidney glomerular filtration rate (SKGFR). The animal experiment included 15 rabbits that underwent 40 dynamic contrast-enhanced CT scans of the kidneys with 1.5 s time interval. Patlak-derived SKGFR was obtained using standard forty-point, two-point (unenhanced phase, arterial phase t α, and portovenous phase t β ), and a modified two-point (MTP) (unenhanced, t α , t β , and a virtual t τ [t τ  = (t α  + t β )/2]) image data, respectively. The MTP-Patlak plot approach was then validated in 13 patients who underwent a triphasic renal contrast-enhanced CT examination. SKGFR measured by 99 m Tc-DTPA clearance was as a standard reference. MTP-Patlak significantly reduced input function errors than two-point Patlak (21.1 ± 16.2 % vs 30.8 ± 15.2 %, p < 0.01) and showed good concordance with standard Patlak for measurement of SKGFR in animal experiment (1.20 ± 0.38 mL/g/min vs 1.51 ± 0.43 mL/g/min; linear correlation coefficient r = 0.87, p < 0.001). Human study showed that mean SKGFR was 45.7 mL/min (range, 26.5-86.2 mL/min) obtained from 99 m Tc-DTPA, and 38.2 mL/min (range, 18.6-79.3 mL/min) obtained from triphasic CT using MTP-Patlak plot. Linear correlation between the two methods was r = 0.75 (p < 0.01). The mean difference between SKGFRs as determined with the two methods was 7.4 ± 9.0 mL/min. The MTP-Patlak approach, featured with simplicity, is feasible in a clinically indicated CT examination for the evaluation of split renal function.

  7. Point-of-Care Hemoglobin/Hematocrit Testing: Comparison of Methodology and Technology.

    PubMed

    Maslow, Andrew; Bert, Arthur; Singh, Arun; Sweeney, Joseph

    2016-04-01

    Point-of-care (POC) testing allows rapid assessment of hemoglobin (Hgb) and hematocrit (Hct) values. This study compared 3 POC testing devices--the Radical-7 pulse oximeter (Radical-7, Neuchȃtel, Switzerland), the i-STAT (Abbott Point of Care, Princeton, NJ), and the GEM 4000 (Instrumentation Laboratory, Bedford, MA)--to the hospital reference device, the UniCel DxH 800 (Beckman Coulter, Brea, CA) in cardiac surgery patients. Prospective study. Tertiary care cardiovascular center. Twenty-four consecutive elective adult cardiac surgery patients. Hgb and Hct values were measured using 3 POC devices (the Radical-7, i-STAT, and GEM 4000) and a reference laboratory device (UniCel DxH 800). Data were collected simultaneously before surgery, after heparin administration, after heparin reversal with protamine, and after sternal closure. Data were analyzed using bias analyses. POC testing data were compared with that of the reference laboratory device. Hgb levels ranged from 6.8 to 15.1 g/dL, and Hct levels ranged from 20.1% to 43.8%. The overall mean bias was lowest with the i-STAT (Hct, 0.22%; Hgb 0.05 g/dL) compared with the GEM 4000 (Hct, 2.15%; Hgb, 0.63 g/dL) and the Radical-7 (Hgb 1.16 g/dL). The range of data for the i-STAT and Radical-7 was larger than that with the GEM 4000, and the pattern or slopes changed significantly with the i-STAT and Radical-7, whereas that of the GEM 4000 remained relatively stable. The GEM 4000 demonstrated a consistent overestimation of laboratory data, which tended to improve after bypass and at lower Hct/Hgb levels. The i-STAT bias changed from overestimation to underestimation, the latter in the post-cardiopulmonary bypass period and at lower Hct/Hgb levels. By contrast, the Radical-7 biases increased during the surgical procedure and in the lower ranges of Hgb. Important clinical differences and limitations were found among the 3 POC testing devices that should caution clinicians from relying on these data as sole determinants of when or when not to perform transfusion in patients. Even though a low bias might support the use of POC data, further analysis of the bias plots demonstrates pattern changes during the surgical procedure and across the range of Hct/Hgb data. Copyright © 2016 Elsevier Inc. All rights reserved.

  8. Errata and update to ;Experimental cross sections for L-shell X-ray production and ionization by protons;

    NASA Astrophysics Data System (ADS)

    Miranda, J.; Lapicki, G.

    2018-01-01

    A compilation of experimental L-shell X-ray production and ionization cross sections induced by proton impact was published recently (Miranda and Lapicki, 2014), collecting 15 439 experimental cross sections. The database covers an energy range from 10 keV to 1 GeV, and targets from 10Ne to 95Am. A correction to several tabulated values that were in error, as well as an update including new data published after 2012 and older references not found previously are given in the present work. The updated data base increased the total number of experimental cross sections by 3.1% to 15 921. A new analysis of the total number of experimental points per year shows that the possible saturation in the cumulative total number of data is increased to 15 950 ± 110 points.

  9. Establishment of stream nutrient criteria by comparing reference conditions with ecological thresholds in a typical eutrophic lake basin.

    PubMed

    Cao, Xiaofeng; Wang, Jie; Jiang, Dalin; Sun, Jinhua; Huang, Yi; Luan, Shengji

    2017-12-13

    The establishment of numeric nutrient criteria is essential to aid the control of nutrient pollution and for protecting and restoring healthy ecological conditions. However, it's necessary to determine whether regional nutrient criteria can be defined in stream ecosystems with a poor ecological status. A database of periphytic diatom samples was collected in July and August 2011 and 2012. In total 172 samples were included in the database with matching environmental variables. Here, percentile estimates, nonparametric change-point analysis (nCPA) and Threshold Indicator Taxa ANalysis (TITAN) were conducted to detect the reference conditions and ecological thresholds along a total nitrogen (TN) and total phosphorus (TP) gradient and ammonia nitrogen (NH 3 -N) for the development of nutrient criteria in the streams of the Lake Dianchi basin. The results highlighted the possibility of establishing regional criteria for nutrient concentrations, which we recommended to be no more than 1.39 mg L -1 for TN, 0.04 mg L -1 for TP and 0.17 mg L -1 for NH 3 -N to prevent nuisance growths of tolerant taxa, and 0.38 mg L -1 for TN, 0.02 mg L -1 for TP and 0.02 mg L -1 for NH 3 -N to maintain high quality waters in streams. Additionally, the influence of excessive background nutrient enrichment on the threshold response, and the ecological interaction with other stressors (HQI, etc.) in the nutrient dynamic process need to be considered to establish the eventual nutrient criteria, regardless of which technique is applied.

  10. A miniaturised image based fluorescence detection system for point-of-care-testing of cocaine abuse

    NASA Astrophysics Data System (ADS)

    Walczak, Rafał; Krüger, Jan; Moynihan, Shane

    2015-08-01

    In this paper, we describe a miniaturised image-based fluorescence detection system and demonstrate its viability as a highly sensitive tool for point-of-care-analysis of drugs of abuse in human sweat with a focus on monitor individuals for drugs of abuse. Investigations of miniaturised and low power optoelectronic configurations and methodologies for real-time image analysis were successfully carried out. The miniaturised fluorescence detection system was validated against a reference detection system under controlled laboratory conditions by analysing spiked sweat samples in dip stick and then strip with sample pad. As a result of the validation studies, a 1 ng mL-1 limit of detection of cocaine in sweat and full agreement of test results with the reference detection system can be reported. Results of the investigations open the way towards a detection system that integrates a hand-held fluorescence reader and a wearable skinpatch, and which can collect and in situ analyse sweat for the presence of cocaine at any point for up to tenths hours.

  11. Does the Level of Graphical Detail of a Virtual Handball Thrower Influence a Goalkeeper’s Motor Response?

    PubMed Central

    Vignais, Nicolas; Bideau, Benoit; Craig, Cathy; Brault, Sébastien; Multon, Franck; Delamarche, Paul; Kulpa, Richard

    2009-01-01

    The authors investigated how different levels of detail (LODs) of a virtual throwing action can influence a handball goalkeeper’s motor response. Goalkeepers attempted to stop a virtual ball emanating from five different graphical LODs of the same virtual throwing action. The five levels of detail were: a textured reference level (L0), a non-textured level (L1), a wire-frame level (L2), a point-light-display (PLD) representation (L3) and a PLD level with reduced ball size (L4). For each motor response made by the goalkeeper we measured and analyzed the time to respond (TTR), the percentage of successful motor responses, the distance between the ball and the closest limb (when the stopping motion was incorrect) and the kinematics of the motion. Results showed that TTR, percentage of successful motor responses and distance with the closest limb were not significantly different for any of the five different graphical LODs. However the kinematics of the motion revealed that the trajectory of the stopping limb was significantly different when comparing the L1 and L3 levels, and when comparing the L1 and L4 levels. These differences in the control of the goalkeeper’s actions suggests that the different level of information available in the PLD representations (L3 and L4) are causing the goalkeeper to adopt different motor strategies to control the approach of their limb to stop the ball. Key points Virtual reality technology can be used to analyze sport performance because it enables standardization and reproduction of sport situations. Defining a minimal graphical level of detail of a virtual action could decrease the real time calculation of a virtual reality system. A Point Light Display graphical representation of a virtual throwing motion seems to influence the regulation of action of real handball goalkeepers. PMID:24149589

  12. A Proposal of New Reference System for the Standard Axial, Sagittal, Coronal Planes of Brain Based on the Serially-Sectioned Images

    PubMed Central

    Park, Jin Seo; Park, Hyo Seok; Shin, Dong Sun; Har, Dong-Hwan; Cho, Zang-Hee; Kim, Young-Bo; Han, Jae-Yong; Chi, Je-Geun

    2010-01-01

    Sectional anatomy of human brain is useful to examine the diseased brain as well as normal brain. However, intracerebral reference points for the axial, sagittal, and coronal planes of brain have not been standardized in anatomical sections or radiological images. We made 2,343 serially-sectioned images of a cadaver head with 0.1 mm intervals, 0.1 mm pixel size, and 48 bit color and obtained axial, sagittal, and coronal images based on the proposed reference system. This reference system consists of one principal reference point and two ancillary reference points. The two ancillary reference points are the anterior commissure and the posterior commissure. And the principal reference point is the midpoint of two ancillary reference points. It resides in the center of whole brain. From the principal reference point, Cartesian coordinate of x, y, z could be made to be the standard axial, sagittal, and coronal planes. PMID:20052359

  13. Study of Individual Characteristic Abdominal Wall Thickness Based on Magnetic Anchored Surgical Instruments

    PubMed Central

    Dong, Ding-Hui; Liu, Wen-Yan; Feng, Hai-Bo; Fu, Yi-Li; Huang, Shi; Xiang, Jun-Xi; Lyu, Yi

    2015-01-01

    Background: Magnetic anchored surgical instruments (MASI), relying on magnetic force, can break through the limitations of the single port approach in dexterity. Individual characteristic abdominal wall thickness (ICAWT) deeply influences magnetic force that determines the safety of MASI. The purpose of this study was to research the abdominal wall characteristics in MASI applied environment to find ICAWT, and then construct an artful method to predict ICAWT, resulting in better safety and feasibility for MASI. Methods: For MASI, ICAWT is referred to the thickness of thickest point in the applied environment. We determined ICAWT through finding the thickest point in computed tomography scans. We also investigated the traits of abdominal wall thickness to discover the factor that can be used to predict ICAWT. Results: Abdominal wall at C point in the middle third lumbar vertebra plane (L3) is the thickest during chosen points. Fat layer thickness plays a more important role in abdominal wall thickness than muscle layer thickness. “BMI-ICAWT” curve was obtained based on abdominal wall thickness of C point in L3 plane, and the expression was as follow: f(x) = P1 × x2 + P2 × x + P3, where P1 = 0.03916 (0.01776, 0.06056), P2 = 1.098 (0.03197, 2.164), P3 = −18.52 (−31.64, −5.412), R-square: 0.99. Conclusions: Abdominal wall thickness of C point at L3 could be regarded as ICAWT. BMI could be a reliable predictor of ICAWT. In the light of “BMI-ICAWT” curve, we may conveniently predict ICAWT by BMI, resulting a better safety and feasibility for MASI. PMID:26228215

  14. High frequency of discordance between antimüllerian hormone and follicle-stimulating hormone levels in serum from estradiol-confirmed days 2 to 4 of the menstrual cycle from 5,354 women in U.S. fertility centers.

    PubMed

    Leader, Benjamin; Hegde, Aparna; Baca, Quentin; Stone, Kimberly; Lannon, Benjamin; Seifer, David B; Broekmans, Frank; Baker, Valerie L

    2012-10-01

    To determine the frequency of clinical discordance between antimüllerian hormone (AMH, ng/mL) and follicle-stimulating hormone (FSH, IU/L) by use of cut points defined by response to controlled ovarian stimulation in the same serum samples drawn on estradiol-confirmed, menstrual cycle days 2 to 4. Retrospective analysis. Fertility centers in 30 U.S. states and a single reference laboratory with uniform testing protocols. 5,354 women, 20 to 45 years of age. None. Frequency of discordance between serum AMH and FSH values. Of the 5,354 women tested, 1 in 5 had discordant AMH and FSH values defined as AMH <0.8 (concerning) with FSH <10 (reassuring) or AMH ≥ 0.8 (reassuring) with FSH ≥ 10 (concerning). Of the women with reassuring FSH values (n = 4,469), the concerning AMH values were found in 1 in 5 women in a highly age-dependent fashion, ranging from 1 in 11 women under 35 years of age to 1 in 3 women above 40 years of age. On the other hand, of the women with reassuring AMH values (n = 3,742), 1 in 18 had concerning FSH values, a frequency that did not vary in a statistically significant fashion by age. Clinical discordance in serum AMH and FSH values was frequent and age dependent using common clinical cut points, a large patient population, one reference laboratory, and uniform testing methodology. This conclusion is generalizable to women undergoing fertility evaluation, although AMH testing has not been standardized among laboratories, and the cut points presented are specific to the laboratory in this study. Copyright © 2012. Published by Elsevier Inc.

  15. Hematology and plasma chemistry reference intervals for cultured shortnose sturgeon (Acipenser brevirostrum).

    PubMed

    Knowles, Susan; Hrubec, Terry C; Smith, Stephen A; Bakal, Robert S

    2006-12-01

    The shortnose sturgeon, Acipenser brevirostrum, is an imperiled species distributed along the Atlantic coast of North America. Interest in replenishing wild stocks with hatchery-reared fish has created a need for accurate hematologic and biochemical reference intervals to evaluate the health of both fish raised in aquaculture systems and fish in the wild. The objective of this study was to generate hematologic and biochemistry reference intervals for healthy shortnose sturgeon. Blood samples were collected in heparinized tubes from 77 shortnose sturgeon raised in flow-through aquaculture systems. Whole blood and plasma samples were analyzed for hematologic and biochemical variables using standard techniques. Reference intervals were calculated as the central 95% (percentile) of data. Hematologic reference intervals (n = 46) were as follows: PCV 26-46%, hemoglobin 5.7-8.7 g/dL, MCV 307-520 fL, MCH 65.9-107.1 pg, MCHC 15-30 g/dL, plasma proteins (refractometry) 2.8-6.0 g/dL, RBC count 0.65-1.09 x 10(6)/microL, total WBC count 28,376-90,789/microL, small lymphocytes 9063-56,656/microL, large lymphocytes 2122-10,435/microL, neutrophils 3758-33,592/microL, monocytes 0-7137/microL, eosinophils 0-1544/microL, thrombocyte-like cells 6863-23,046/microL, thrombocytes 32,205-122,179/microL, and neutrophil:lymphocyte ratio 0.068-1.026. Plasma chemistry reference intervals (n = 77) were as follows: total protein 2.7-5.3 g/dL, albumin 0.8-1.7 g/dL, globulins 1.8-3.7 mg/dL, creatinine 0-1.4 mg/dL, total bilirubin 0-0.1 mg/dL, alkaline phosphatase 47-497 U/L, aspartate aminotransferase 90-311 U/L, sodium 124-141 mmol/L, potassium 2.9-3.7 mmol/L, chloride 106-121 mmol/L, calcium 6.6-12.1 mg/dL, magnesium 1.6-2.3 mg/dL, phosphorus 5.1-8.1 mg/dL, glucose 37-74 mg/dL, cholesterol 42-133 mg/dL, and osmolality 232-289 mOsm/kg. Reference values reported here will be useful for the early detection, identification, and monitoring of disease and sublethal conditions in cultured shortnose sturgeon.

  16. CD4 Enumeration Technologies: A Systematic Review of Test Performance for Determining Eligibility for Antiretroviral Therapy

    PubMed Central

    Peeling, Rosanna W.; Sollis, Kimberly A.; Glover, Sarah; Crowe, Suzanne M.; Landay, Alan L.; Cheng, Ben; Barnett, David; Denny, Thomas N.; Spira, Thomas J.; Stevens, Wendy S.; Crowley, Siobhan; Essajee, Shaffiq; Vitoria, Marco; Ford, Nathan

    2015-01-01

    Background Measurement of CD4+ T-lymphocytes (CD4) is a crucial parameter in the management of HIV patients, particularly in determining eligibility to initiate antiretroviral treatment (ART). A number of technologies exist for CD4 enumeration, with considerable variation in cost, complexity, and operational requirements. We conducted a systematic review of the performance of technologies for CD4 enumeration. Methods and Findings Studies were identified by searching electronic databases MEDLINE and EMBASE using a pre-defined search strategy. Data on test accuracy and precision included bias and limits of agreement with a reference standard, and misclassification probabilities around CD4 thresholds of 200 and 350 cells/μl over a clinically relevant range. The secondary outcome measure was test imprecision, expressed as % coefficient of variation. Thirty-two studies evaluating 15 CD4 technologies were included, of which less than half presented data on bias and misclassification compared to the same reference technology. At CD4 counts <350 cells/μl, bias ranged from -35.2 to +13.1 cells/μl while at counts >350 cells/μl, bias ranged from -70.7 to +47 cells/μl, compared to the BD FACSCount as a reference technology. Misclassification around the threshold of 350 cells/μl ranged from 1-29% for upward classification, resulting in under-treatment, and 7-68% for downward classification resulting in overtreatment. Less than half of these studies reported within laboratory precision or reproducibility of the CD4 values obtained. Conclusions A wide range of bias and percent misclassification around treatment thresholds were reported on the CD4 enumeration technologies included in this review, with few studies reporting assay precision. The lack of standardised methodology on test evaluation, including the use of different reference standards, is a barrier to assessing relative assay performance and could hinder the introduction of new point-of-care assays in countries where they are most needed. PMID:25790185

  17. A color prediction model for imagery analysis

    NASA Technical Reports Server (NTRS)

    Skaley, J. E.; Fisher, J. R.; Hardy, E. E.

    1977-01-01

    A simple model has been devised to selectively construct several points within a scene using multispectral imagery. The model correlates black-and-white density values to color components of diazo film so as to maximize the color contrast of two or three points per composite. The CIE (Commission Internationale de l'Eclairage) color coordinate system is used as a quantitative reference to locate these points in color space. Superimposed on this quantitative reference is a perceptional framework which functionally contrasts color values in a psychophysical sense. This methodology permits a more quantitative approach to the manual interpretation of multispectral imagery while resulting in improved accuracy and lower costs.

  18. Defining Multiple Characteristic Raman Bands of α-Amino Acids as Biomarkers for Planetary Missions Using a Statistical Method

    NASA Astrophysics Data System (ADS)

    Rolfe, S. M.; Patel, M. R.; Gilmour, I.; Olsson-Francis, K.; Ringrose, T. J.

    2016-06-01

    Biomarker molecules, such as amino acids, are key to discovering whether life exists elsewhere in the Solar System. Raman spectroscopy, a technique capable of detecting biomarkers, will be on board future planetary missions including the ExoMars rover. Generally, the position of the strongest band in the spectra of amino acids is reported as the identifying band. However, for an unknown sample, it is desirable to define multiple characteristic bands for molecules to avoid any ambiguous identification. To date, there has been no definition of multiple characteristic bands for amino acids of interest to astrobiology. This study examined l-alanine, l-aspartic acid, l-cysteine, l-glutamine and glycine and defined several Raman bands per molecule for reference as characteristic identifiers. Per amino acid, 240 spectra were recorded and compared using established statistical tests including ANOVA. The number of characteristic bands defined were 10, 12, 12, 14 and 19 for l-alanine (strongest intensity band: 832 cm-1), l-aspartic acid (938 cm-1), l-cysteine (679 cm-1), l-glutamine (1090 cm-1) and glycine (875 cm-1), respectively. The intensity of bands differed by up to six times when several points on the crystal sample were rotated through 360 °; to reduce this effect when defining characteristic bands for other molecules, we find that spectra should be recorded at a statistically significant number of points per sample to remove the effect of sample rotation. It is crucial that sets of characteristic Raman bands are defined for biomarkers that are targets for future planetary missions to ensure a positive identification can be made.

  19. Defining Multiple Characteristic Raman Bands of α-Amino Acids as Biomarkers for Planetary Missions Using a Statistical Method.

    PubMed

    Rolfe, S M; Patel, M R; Gilmour, I; Olsson-Francis, K; Ringrose, T J

    2016-06-01

    Biomarker molecules, such as amino acids, are key to discovering whether life exists elsewhere in the Solar System. Raman spectroscopy, a technique capable of detecting biomarkers, will be on board future planetary missions including the ExoMars rover. Generally, the position of the strongest band in the spectra of amino acids is reported as the identifying band. However, for an unknown sample, it is desirable to define multiple characteristic bands for molecules to avoid any ambiguous identification. To date, there has been no definition of multiple characteristic bands for amino acids of interest to astrobiology. This study examined L-alanine, L-aspartic acid, L-cysteine, L-glutamine and glycine and defined several Raman bands per molecule for reference as characteristic identifiers. Per amino acid, 240 spectra were recorded and compared using established statistical tests including ANOVA. The number of characteristic bands defined were 10, 12, 12, 14 and 19 for L-alanine (strongest intensity band: 832 cm(-1)), L-aspartic acid (938 cm(-1)), L-cysteine (679 cm(-1)), L-glutamine (1090 cm(-1)) and glycine (875 cm(-1)), respectively. The intensity of bands differed by up to six times when several points on the crystal sample were rotated through 360 °; to reduce this effect when defining characteristic bands for other molecules, we find that spectra should be recorded at a statistically significant number of points per sample to remove the effect of sample rotation. It is crucial that sets of characteristic Raman bands are defined for biomarkers that are targets for future planetary missions to ensure a positive identification can be made.

  20. Automatic determination of trunk diameter, crown base and height of scots pine (Pinus Sylvestris L.) Based on analysis of 3D point clouds gathered from multi-station terrestrial laser scanning. (Polish Title: Automatyczne okreslanie srednicy pnia, podstawy korony oraz wysokosci sosny zwyczajnej (Pinus Silvestris L.) Na podstawie analiz chmur punktow 3D pochodzacych z wielostanowiskowego naziemnego skanowania laserowego)

    NASA Astrophysics Data System (ADS)

    Ratajczak, M.; Wężyk, P.

    2015-12-01

    Rapid development of terrestrial laser scanning (TLS) in recent years resulted in its recognition and implementation in many industries, including forestry and nature conservation. The use of the 3D TLS point clouds in the process of inventory of trees and stands, as well as in the determination of their biometric features (trunk diameter, tree height, crown base, number of trunk shapes), trees and lumber size (volume of trees) is slowly becoming a practice. In addition to the measurement precision, the primary added value of TLS is the ability to automate the processing of the clouds of points 3D in the direction of the extraction of selected features of trees and stands. The paper presents the original software (GNOM) for the automatic measurement of selected features of trees, based on the cloud of points obtained by the ground laser scanner FARO. With the developed algorithms (GNOM), the location of tree trunks on the circular research surface was specified and the measurement was performed; the measurement covered the DBH (l: 1.3m), further diameters of tree trunks at different heights of the tree trunk, base of the tree crown and volume of the tree trunk (the selection measurement method), as well as the tree crown. Research works were performed in the territory of the Niepolomice Forest in an unmixed pine stand (Pinussylvestris L.) on the circular surface with a radius of 18 m, within which there were 16 pine trees (14 of them were cut down). It was characterized by a two-storey and even-aged construction (147 years old) and was devoid of undergrowth. Ground scanning was performed just before harvesting. The DBH of 16 pine trees was specified in a fully automatic way, using the algorithm GNOM with an accuracy of +2.1%, as compared to the reference measurement by the DBH measurement device. The medium, absolute measurement error in the cloud of points - using semi-automatic methods "PIXEL" (between points) and PIPE (fitting the cylinder) in the FARO Scene 5.x., showed the error, 3.5% and 5.0%,.respectively The reference height was assumed as the measurement performed by the tape on the cut tree. The average error of automatic determination of the tree height by the algorithm GNOM based on the TLS point clouds amounted to 6.3% and was slightly higher than when using the manual method of measurements on profiles in the TerraScan (Terrasolid; the error of 5.6%). The relatively high value of the error may be mainly related to the small number of points TLS in the upper parts of crowns. The crown height measurement showed the error of +9.5%. The reference in this case was the tape measurement performed already on the trunks of cut pine trees. Processing the clouds of points by the algorithms GNOM for 16 analyzed trees took no longer than 10 min. (37 sec. /tree). The paper mainly showed the TLS measurement innovation and its high precision in acquiring biometric data in forestry, and at the same time also the further need to increase the degree of automation of processing the clouds of points 3D from terrestrial laser scanning.

  1. Establishment of reference intervals for complete blood count parameters during normal pregnancy in Beijing.

    PubMed

    Li, Aiwei; Yang, Shuo; Zhang, Jie; Qiao, Rui

    2017-11-01

    To observe the changes of complete blood count (CBC) parameters during pregnancy and establish appropriate reference intervals for healthy pregnant women. Healthy pregnant women took the blood tests at all trimesters. All blood samples were processed on Sysmex XE-2100. The following CBC parameters were analyzed: red blood cell count (RBC), hemoglobin (Hb), hematocrit (Hct), mean corpuscular volume (MCV), mean corpuscular hemoglobin (MCH), mean corpuscular hemoglobin concentration (MCHC), red blood cell distribution width (RDW), platelet count (PLT), mean platelet volume (MPV), platelet distribution width (PDW), white blood cell count (WBC), and leukocyte differential count. Reference intervals were established using the 2.5th and 97.5th percentile of the distribution. Complete blood count parameters showed dynamic changes during trimesters. RBC, Hb, Hct declined at trimester 1, reaching their lowest point at trimester 2, and began to rise again at trimester 3. WBC, neutrophil count (Neut), monocyte count (MONO), RDW, and PDW went up from trimester 1 to trimester 3. On the contrary, MCHC, lymphocyte count (LYMPH), PLT, and MPV gradually descended during pregnancy. There were statistical significances in all CBC parameters between pregnant women and normal women, regardless of the trimesters (P<.001). The median obtained were (normal vs pregnancy) as follows: RBC 4.50 vs 3.94×10 12 /L, Hb 137 vs 120 g/L, WBC 5.71 vs 9.06×10 9 /L, LYMPH% 32.2 vs 18.0, Neut% 58.7 vs 75.0, and PLT 251 vs 202×10 9 /L. The changes of CBC parameters during pregnancy are described, and reference intervals for Beijing pregnant women are demonstrated in this study. © 2017 Wiley Periodicals, Inc.

  2. Reference measurement procedure for the determination of electrolytes in human blood via ICP-OES measurement

    NASA Astrophysics Data System (ADS)

    Grote-Koska, D.; Klauke, R.; Brand, K.; Schumann, G.

    2018-04-01

    The determination of electrolytes in human body fluids is one of the most frequently performed analyses in clinical routine laboratories. Metrological traceability of measurement results in patient samples is essential and requires the involvement of higher order reference measurement procedures wherever available. Here, the authors present the evaluation of a higher order reference system for the simultaneous determination of K+, Li+, Na+, Ca2+ and Mg2+ in blood serum and plasma. In the same order, the determined measurement performances were as follows: measurement ranges: 0.75 mmol l-1-75.0 mmol l-1, 0.05 mmol l-1-5.00 mmol l-1, 5 mmol l-1-200 mmol l-1, 0.4 mmol l-1-8.0 mmol l-1 and 0.1 mmol l-1-4.0 mmol l-1. Measurement imprecision: CVs were  ⩽1.1% for intra assay investigations and  ⩽1.8% for long term inter assay investigations for all measurands. Excellent accuracy was found testing certified Standard Reference Materials from NIST: SRM 909 (deviations from 0.0% to 1.1%) and SRM 956 (deviations from 0.0% to 1.5%). Intercomparisons with the German Metrology Institute (PTB) revealed differences from 0.1% to 0.8%. Matrix influences and carry over were not detectable. The expanded combined measurement uncertainties for the determination of the reference method values were estimated as  ⩾1.5% (k  =  2) for each measurand. The reference measurement procedure is accredited by the German accreditation body (DAkkS) in association with the German calibration service (DKD) according to ISO 17025 and ISO 15195. Services comprise the certification of calibrators, control materials and samples used in proficiency testing schemes.

  3. Reference Values of 14 Serum Trace Elements for Pregnant Chinese Women: A Cross-Sectional Study in the China Nutrition and Health Survey 2010-2012.

    PubMed

    Liu, Xiaobing; Zhang, Yu; Piao, Jianhua; Mao, Deqian; Li, Yajie; Li, Weidong; Yang, Lichen; Yang, Xiaoguang

    2017-03-21

    The development of reference values of trace elements is recognized as a fundamental prerequisite for the assessment of trace element nutritional status and health risks. In this study, a total of 1400 pregnant women aged 27.0 ± 4.5 years were randomly selected from the China Nutrition and Health Survey 2010-2012 (CNHS 2010-2012). The concentrations of 14 serum trace elements were determined by high-resolution inductively coupled plasma mass spectrometry. Reference values were calculated covering the central 95% reference intervals (P2.5-P97.5) after excluding outliers by Dixon's test. The overall reference values of serum trace elements were 131.5 (55.8-265.0 μg/dL for iron (Fe), 195.5 (107.0-362.4) μg/dL for copper (Cu), 74.0 (51.8-111.3) μg/dL for zinc (Zn), 22.3 (14.0-62.0) μg/dL for rubidium (Rb), 72.2 (39.9-111.6) μg/L for selenium (Se), 45.9 (23.8-104.3) μg/L for strontium (Sr), 1.8 (1.2-3.6) μg/L for molybdenum (Mo), 2.4 (1.2-8.4) μg/L for manganese (Mn), 1.9 (0.6-9.0) ng/L for lead (Pb), 1.1 (0.3-5.6) ng/L for arsenic (As), 835.6 (219.8-4287.7) ng/L for chromium (Cr), 337.9 (57.0-1130.0) ng/L for cobalt (Co), 193.2 (23.6-2323.1) ng/L for vanadium (V), and 133.7 (72.1-595.1) ng/L for cadmium (Cd). Furthermore, some significant differences in serum trace element reference values were observed between different groupings of age intervals, residences, anthropometric status, and duration of pregnancy. We found that serum Fe, Zn, and Se concentrations significantly decreased, whereas serum Cu, Sr, and Co concentrations elevated progressively compared with reference values of 14 serum trace elements in pregnant Chinese women. The reference values of serum trace elements established could play a key role in the following nutritional status and health risk assessment.

  4. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Slattery, Stuart R

    ExaMPM is a mini-application for the Material Point Method (MPM) for studying the application of MPM to future exascale computing systems. MPM is a general method for computational mechanics and fluids and is used in a wide variety of science and engineering disciplines to study problems with large deformations, phase change, fracture, and other phenomena. ExaMPM provides a reference implementation of MPM as described in the 1994 work of Sulsky et.al. (Sulsky, Deborah, Zhen Chen, and Howard L. Schreyer. "A particle method for history-dependent materials." Computer methods in applied mechanics and engineering 118.1-2 (1994): 179-196.). The software can solve basicmore » MPM problems in solid mechanics using the original algorithm of Sulsky with explicit time integration, basic geometries, and free-slip and no-slip boundary conditions as described in the reference. ExaMPM is intended to be used as a starting point to design new parallel algorithms for the next generation of DOE supercomputers.« less

  5. Intracellular L-arginine concentration does not determine NO production in endothelial cells: Implications on the 'L-arginine paradox'

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shin, Soyoung; Mohan, Srinidi; Fung, Ho-Leung, E-mail: hlfung@buffalo.edu

    2011-11-04

    Highlights: Black-Right-Pointing-Pointer Our findings provide a possible solution to the 'L-arginine paradox'. Black-Right-Pointing-Pointer Extracellular L-arginine concentration is the major determinant of NO production. Black-Right-Pointing-Pointer Cellular L-arginine action is limited by cellular ARG transport, not the K{sub m} of NOS. Black-Right-Pointing-Pointer We explain how L-arginine supplementation can work to increase endothelial function. -- Abstract: We examined the relative contributory roles of extracellular vs. intracellular L-arginine (ARG) toward cellular activation of endothelial nitric oxide synthase (eNOS) in human endothelial cells. EA.hy926 human endothelial cells were incubated with different concentrations of {sup 15}N{sub 4}-ARG, ARG, or L-arginine ethyl ester (ARG-EE) for 2 h.more » To modulate ARG transport, siRNA for ARG transporter (CAT-1) vs. sham siRNA were transfected into cells. ARG transport activity was assessed by cellular fluxes of ARG, {sup 15}N{sub 4}-ARG, dimethylarginines, and L-citrulline by an LC-MS/MS assay. eNOS activity was determined by nitrite/nitrate accumulation, either via a fluorometric assay or by{sup 15}N-nitrite or estimated {sup 15}N{sub 3}-citrulline concentrations when {sup 15}N{sub 4}-ARG was used to challenge the cells. We found that ARG-EE incubation increased cellular ARG concentration but no increase in nitrite/nitrate was observed, while ARG incubation increased both cellular ARG concentration and nitrite accumulation. Cellular nitrite/nitrate production did not correlate with cellular total ARG concentration. Reduced {sup 15}N{sub 4}-ARG cellular uptake in CAT-1 siRNA transfected cells vs. control was accompanied by reduced eNOS activity, as determined by {sup 15}N-nitrite, total nitrite and {sup 15}N{sub 3}-citrulline formation. Our data suggest that extracellular ARG, not intracellular ARG, is the major determinant of NO production in endothelial cells. It is likely that once transported inside the cell, ARG can no longer gain access to the membrane-bound eNOS. These observations indicate that the 'L-arginine paradox' should not consider intracellular ARG concentration as a reference point.« less

  6. BiliChek transcutaneous bilirubin meter overestimates serum bilirubin as measured by the Doumas reference method.

    PubMed

    Karon, Brad S; Wickremasinghe, Andrea C; Lo, Stanley F; Saenger, Amy K; Cook, Walter J

    2010-08-01

    To determine the relationship between BiliChek TcB (Respironics, Marietta GA) and Doumas reference serum or plasma total bilirubin (TSB). Pooled samples with values assigned by the Doumas reference method were used to establish the relationship between a local laboratory and reference Doumas TSB. We then established the relationship between TcB and TSB in the 3 months before and after reassignment of calibrator setpoints undertaken to match the local laboratory to Doumas reference bilirubin values. Before calibrator setpoint reassignment TSB as measured in our laboratory overestimated Doumas reference bilirubin. After calibrator adjustment laboratory TSB was within 1.7-6.8 micromol/L (0.1-0.4 mg/dL) of Doumas reference values. Mean bias between BiliChek TcB and TSB was 42.8+/-22.2 micromol/L (2.5+/-1.3mg/dL) (n=94) before and 49.6+/-22.2 micromol/L (2.9+/-1.3mg/dL) (n=115) after calibration adjustment. BiliChek TcB significantly overestimates TSB as measured by the Doumas reference method. 2010 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  7. Real-time estimation of ionospheric delay using GPS measurements

    NASA Astrophysics Data System (ADS)

    Lin, Lao-Sheng

    1997-12-01

    When radio waves such as the GPS signals propagate through the ionosphere, they experience an extra time delay. The ionospheric delay can be eliminated (to the first order) through a linear combination of L1 and L2 observations from dual-frequency GPS receivers. Taking advantage of this dispersive principle, one or more dual- frequency GPS receivers can be used to determine a model of the ionospheric delay across a region of interest and, if implemented in real-time, can support single-frequency GPS positioning and navigation applications. The research objectives of this thesis were: (1) to develop algorithms to obtain accurate absolute Total Electron Content (TEC) estimates from dual-frequency GPS observables, and (2) to develop an algorithm to improve the accuracy of real-time ionosphere modelling. In order to fulfil these objectives, four algorithms have been proposed in this thesis. A 'multi-day multipath template technique' is proposed to mitigate the pseudo-range multipath effects at static GPS reference stations. This technique is based on the assumption that the multipath disturbance at a static station will be constant if the physical environment remains unchanged from day to day. The multipath template, either single-day or multi-day, can be generated from the previous days' GPS data. A 'real-time failure detection and repair algorithm' is proposed to detect and repair the GPS carrier phase 'failures', such as the occurrence of cycle slips. The proposed algorithm uses two procedures: (1) application of a statistical test on the state difference estimated from robust and conventional Kalman filters in order to detect and identify the carrier phase failure, and (2) application of a Kalman filter algorithm to repair the 'identified carrier phase failure'. A 'L1/L2 differential delay estimation algorithm' is proposed to estimate GPS satellite transmitter and receiver L1/L2 differential delays. This algorithm, based on the single-site modelling technique, is able to estimate the sum of the satellite and receiver L1/L2 differential delay for each tracked GPS satellite. A 'UNSW grid-based algorithm' is proposed to improve the accuracy of real-time ionosphere modelling. The proposed algorithm is similar to the conventional grid-based algorithm. However, two modifications were made to the algorithm: (1) an 'exponential function' is adopted as the weighting function, and (2) the 'grid-based ionosphere model' estimated from the previous day is used to predict the ionospheric delay ratios between the grid point and reference points. (Abstract shortened by UMI.)

  8. Accuracy of two osmometers on standard samples: electrical impedance technique and freezing point depression technique

    NASA Astrophysics Data System (ADS)

    García-Resúa, Carlos; Pena-Verdeal, Hugo; Miñones, Mercedes; Gilino, Jorge; Giraldez, Maria J.; Yebra-Pimentel, Eva

    2013-11-01

    High tear fluid osmolarity is a feature common to all types of dry eye. This study was designed to establish the accuracy of two osmometers, a freezing point depression osmometer (Fiske 110) and an electrical impedance osmometer (TearLab™) by using standard samples. To assess the accuracy of the measurements provided by the two instruments we used 5 solutions of known osmolarity/osmolality; 50, 290 and 850 mOsm/kg and 292 and 338 mOsm/L. Fiske 110 is designed to be used in samples of 20 μl, so measurements were made on 1:9, 1:4, 1:1 and 1:0 dilutions of the standards. Tear Lab is addressed to be used in tear film and only a sample of 0.05 μl is required, so no dilutions were employed. Due to the smaller measurement range of the TearLab, the 50 and 850 mOsm/kg standards were not included. 20 measurements per standard sample were used and differences with the reference value was analysed by one sample t-test. Fiske 110 showed that osmolarity measurements differed statistically from standard values except those recorded for 290 mOsm/kg standard diluted 1:1 (p = 0.309), the 292 mOsm/L H2O sample (1:1) and 338 mOsm/L H2O standard (1:4). The more diluted the sample, the higher the error rate. For the TearLab measurements, one-sample t-test indicated that all determinations differed from the theoretical values (p = 0.001), though differences were always small. For undiluted solutions, Fiske 110 shows similar performance than TearLab. However, for the diluted standards, Fiske 110 worsens.

  9. Clinical utility of Abbott Precision Xceed Pro® ketone meter in diabetic patients.

    PubMed

    Yu, Hoi-Ying Elsie; Agus, Michael; Kellogg, Mark D

    2011-11-01

    Diagnosis and management of diabetic ketoacidosis (DKA) often rely on the measurement of urine ketones along with blood glucose, anion gap, and pH. These values, however, do not reliably reflect the severity of ketoacidosis. The Abbott Precision Xceed Pro® meter is an FDA-approved device that quantitatively measures β-hydroxybutyrate (BOH) in whole blood. This study was undertaken to determine whether the ketone meter meets the analytical criteria to aid DKA diagnosis and management in the hospital. 54 heparinized venous whole blood BOH concentrations from 27 diabetic patients were measured by the Abbott meter, and compared with the plasma BOH concentrations measured with Stanbio reagent (reference method). Measurements were done in the hospital central laboratory. Of the 54 pairs of specimens analyzed, 17 pairs displayed a difference of >15% between the two methods. Nearly all discrepant points occurred when BOH >5 mmol/L (reference method). Linearity evaluation revealed that the meter is not linear from 0.0 to 8.0 mmol/L, contrary to the claim by the manufacturer. Further, we identified acetoacetate, a metabolite commonly present in DKA patients, as a potential interfering substance for the meter BOH measurement. BOH measurements by the Abbott meter up to 3 mmol/L correlate well with the reference method, but become discrepant above that point. While this characteristic may be useful in the diagnosis of DKA, it may not allow clinicians to serially follow the response to therapy in hospitalized DKA patients with BOH values greater than 5 mmol/L (reference method). © 2011 John Wiley & Sons A/S.

  10. The motion near L{sub 4} equilibrium point under non-point mass primaries

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Huda, I. N., E-mail: ibnu.nurul@students.itb.ac.id; Utama, J. A.; Madley, D.

    2015-09-30

    The Circular Restricted Three-Body Problem (CRTBP) possesses five equilibrium points, that comprise three collinear (L{sub 1}, L{sub 2}, and L{sub 3}) and two triangular points (L{sub 4} and L{sub 5}). The classical study (with the primaries are point mass) suggests that the equilibrium points may cause the velocity of infinitesimal object relatively becomes zero and reveals the zero velocity curve. We study the motion of infinitesimal object near triangular equilibrium point (L{sub 4}) and determine its zero velocity curve. We extend the study by taking into account the effects of radiation of the bigger primary (q{sub 1} ≠ 1, q{submore » 2} = 1) and oblateness of the smaller primary (A{sub 1} = 0, A{sub 2} ≠ 0). The location of L{sub 4} is analytically derived then the stability of L{sub 4} and its zero velocity curves are studied numerically. Our study suggests that the oblateness and the radiation of primaries may affect the stability and zero velocity curve around L{sub 4}.« less

  11. Identification and validation of reference genes for quantitative real-time PCR normalization and its applications in lycium.

    PubMed

    Zeng, Shaohua; Liu, Yongliang; Wu, Min; Liu, Xiaomin; Shen, Xiaofei; Liu, Chunzhao; Wang, Ying

    2014-01-01

    Lycium barbarum and L. ruthenicum are extensively used as traditional Chinese medicinal plants. Next generation sequencing technology provides a powerful tool for analyzing transcriptomic profiles of gene expression in non-model species. Such gene expression can then be confirmed with quantitative real-time polymerase chain reaction (qRT-PCR). Therefore, use of systematically identified suitable reference genes is a prerequisite for obtaining reliable gene expression data. Here, we calculated the expression stability of 18 candidate reference genes across samples from different tissues and grown under salt stress using geNorm and NormFinder procedures. The geNorm-determined rank of reference genes was similar to those defined by NormFinder with some differences. Both procedures confirmed that the single most stable reference gene was ACNTIN1 for L. barbarum fruits, H2B1 for L. barbarum roots, and EF1α for L. ruthenicum fruits. PGK3, H2B2, and PGK3 were identified as the best stable reference genes for salt-treated L. ruthenicum leaves, roots, and stems, respectively. H2B1 and GAPDH1+PGK1 for L. ruthenicum and SAMDC2+H2B1 for L. barbarum were the best single and/or combined reference genes across all samples. Finally, expression of salt-responsive gene NAC, fruit ripening candidate gene LrPG, and anthocyanin genes were investigated to confirm the validity of the selected reference genes. Suitable reference genes identified in this study provide a foundation for accurately assessing gene expression and further better understanding of novel gene function to elucidate molecular mechanisms behind particular biological/physiological processes in Lycium.

  12. Evaluation of a point-of-care electrochemical meter to detect subclinical ketosis and hypoglycaemia in lactating dairy cows.

    PubMed

    Zakian, A; Tehrani-Sharif, M; Mokhber-Dezfouli, M R; Nouri, M; Constable, P D

    2017-04-01

    To evaluate and validate a hand-held electrochemical meter (Precision Xtra®) as a screening test for subclinical ketosis and hypoglycaemia in lactating dairy cattle. Method comparison study using a convenience sample. Blood samples were collected into plain tubes from the coccygeal vessels of 181 Holstein cows at 2-4 weeks of lactation during summer in Iran. Blood β-hydroxybutyrate concentration (BHB) and glucose concentration were immediately measured by the electrochemical meter after applying 20 μL of blood to the reagent strip. Passing-Bablok regression and Bland-Altman plots were used to determine the accuracy of the meter against laboratory reference methods (BHB dehydrogenase and glucose oxidase). Serum BHB ranged from 0.1 to 7.3 mmol/L and serum glucose ranged from 0.9 to 5.1 mmol/L. Passing-Bablok regression analysis indicated that the electrochemical meter and reference methods were linearly related for BHB and glucose, with a slope estimate that was not significantly different from 1.00. Clinically minor, but statistically significant, differences were present for the intercept value for Passing-Bablok regression analysis for BHB and glucose, and bias estimates in the Bland-Altman plots for BHB and glucose. The electrochemical meter provided a clinically useful method to detect subclinical ketosis and hypoglycaemia in lactating dairy cows. Compared with other method validation studies using the meter, we attributed the improved performance of the electrochemical meter to application of a fixed volume of blood (20 μL) to the reagent strip, use of the meter in hot ambient conditions and use of glucose oxidase as the reference method for glucose analysis. © 2017 Australian Veterinary Association.

  13. Reference Values of 14 Serum Trace Elements for Pregnant Chinese Women: A Cross-Sectional Study in the China Nutrition and Health Survey 2010–2012

    PubMed Central

    Liu, Xiaobing; Zhang, Yu; Piao, Jianhua; Mao, Deqian; Li, Yajie; Li, Weidong; Yang, Lichen; Yang, Xiaoguang

    2017-01-01

    The development of reference values of trace elements is recognized as a fundamental prerequisite for the assessment of trace element nutritional status and health risks. In this study, a total of 1400 pregnant women aged 27.0 ± 4.5 years were randomly selected from the China Nutrition and Health Survey 2010–2012 (CNHS 2010–2012). The concentrations of 14 serum trace elements were determined by high-resolution inductively coupled plasma mass spectrometry. Reference values were calculated covering the central 95% reference intervals (P2.5–P97.5) after excluding outliers by Dixon’s test. The overall reference values of serum trace elements were 131.5 (55.8-265.0 μg/dL for iron (Fe), 195.5 (107.0–362.4) μg/dL for copper (Cu), 74.0 (51.8–111.3) μg/dL for zinc (Zn), 22.3 (14.0–62.0) μg/dL for rubidium (Rb), 72.2 (39.9–111.6) μg/L for selenium (Se), 45.9 (23.8-104.3) μg/L for strontium (Sr), 1.8 (1.2–3.6) μg/L for molybdenum (Mo), 2.4 (1.2–8.4) μg/L for manganese (Mn), 1.9 (0.6–9.0) ng/L for lead (Pb), 1.1 (0.3-5.6) ng/L for arsenic (As), 835.6 (219.8–4287.7) ng/L for chromium (Cr), 337.9 (57.0–1130.0) ng/L for cobalt (Co), 193.2 (23.6–2323.1) ng/L for vanadium (V), and 133.7 (72.1–595.1) ng/L for cadmium (Cd). Furthermore, some significant differences in serum trace element reference values were observed between different groupings of age intervals, residences, anthropometric status, and duration of pregnancy. We found that serum Fe, Zn, and Se concentrations significantly decreased, whereas serum Cu, Sr, and Co concentrations elevated progressively compared with reference values of 14 serum trace elements in pregnant Chinese women. The reference values of serum trace elements established could play a key role in the following nutritional status and health risk assessment. PMID:28335545

  14. Workshop on Future Directions for Optical Information Processing.

    DTIC Science & Technology

    1981-03-01

    h . The i reference point source simultaneously illuminates the i member of a family of n phase-encoding Aiffusers (e.g. shower glass , ground glass ...diffuser (ground glass ) section illuminated with a plane wave [35.37). The n(n-1) - 4(3) - 12 crosstalk terms have been distributed into the noise...for 2x2 input Fig. 6. Outnut of processor analogous to that array, l.Sx magnifier, ground glass diffuser of Fig. 5, but using spherical wavefront and

  15. Study of the GPS inter-frequency calibration of timing receivers

    NASA Astrophysics Data System (ADS)

    Defraigne, P.; Huang, W.; Bertrand, B.; Rovera, D.

    2018-02-01

    When calibrating Global Positioning System (GPS) stations dedicated to timing, the hardware delays of P1 and P2, the P(Y)-codes on frequencies L1 and L2, are determined separately. In the international atomic time (TAI) network the GPS stations of the time laboratories are calibrated relatively against reference stations. This paper aims at determining the consistency between the P1 and P2 hardware delays (called dP1 and dP2) of these reference stations, and to look at the stability of the inter-signal hardware delays dP1-dP2 of all the stations in the network. The method consists of determining the dP1-dP2 directly from the GPS pseudorange measurements corrected for the frequency-dependent antenna phase center and the frequency-dependent ionosphere corrections, and then to compare these computed dP1-dP2 to the calibrated values. Our results show that the differences between the computed and calibrated dP1-dP2 are well inside the expected combined uncertainty of the two quantities. Furthermore, the consistency between the calibrated time transfer solution obtained from either single-frequency P1 or dual-frequency P3 for reference laboratories is shown to be about 1.0 ns, well inside the 2.1 ns uB uncertainty of a time transfer link based on GPS P3 or Precise Point Positioning. This demonstrates the good consistency between the P1 and P2 hardware delays of the reference stations used for calibration in the TAI network. The long-term stability of the inter-signal hardware delays is also analysed from the computed dP1-dP2. It is shown that only variations larger than 2 ns can be detected for a particular station, while variations of 200 ps can be detected when differentiating the results between two stations. Finally, we also show that in the differential calibration process as used in the TAI network, using the same antenna phase center or using different positions for L1 and L2 signals gives maximum differences of 200 ps on the hardware delays of the separate codes P1 and P2; however, the final impact on the P3 combination is less than 10 ps.

  16. Use of calcium folinate in the management of accidental methotrexate ingestion in two dogs.

    PubMed

    Lewis, Daniel H; Barfield, Dominic M; Humm, Karen R; Goggs, Robert A

    2010-12-15

    2 English Pointers were suspected of having consumed toxic doses of methotrexate, a dihydrofolate reductase inhibitor frequently used in human and veterinary chemotherapeutic protocols. Potentially toxic plasma concentrations of methotrexate were detected in both dogs. Results of physical examination, a CBC, blood gas analysis, and serum biochemical analysis were predominantly unremarkable, although 1 dog had mild hyponatremia (1372 mmol/L; reference range, 140 to 153 mmol/L) and mild hypocalcemia (1.03 mmol of ionized calcium/L; reference range, 1.13 to 1.33 mmol of ionized calcium/L). Point-of-care determination of plasma methotrexate concentrations was not available; thus, palliative care was provided. Emesis was induced in both dogs by SC administration of apomorphine, and 3 doses of a suspension of activated charcoal with sorbitol were administered orally over a 6-hour period. Fluid diuresis was initiated in both dogs by administration of a compound sodium lactate solution, and N-acetylcysteine was administered IV to both dogs as a hepatoprotectant. A solution of calcium folinate (also known as leucovorin) was administered IV to both dogs to mitigate the effects of ingested methotrexate. No adverse effects associated with calcium folinate administration were identified, and no clinical or pathological evidence of methotrexate intoxication was detected. IV administration of calcium folinate appeared to prevent the pathological sequelae of methotrexate intoxication without adverse effects. Administration of calcium folinate is recommended for the treatment of dogs with suspected or confirmed methotrexate overdose.

  17. Two Point Space-Time Correlation of Density Fluctuations Measured in High Velocity Free Jets

    NASA Technical Reports Server (NTRS)

    Panda, Jayanta

    2006-01-01

    Two-point space-time correlations of air density fluctuations in unheated, fully-expanded free jets at Mach numbers M(sub j) = 0.95, 1.4, and 1.8 were measured using a Rayleigh scattering based diagnostic technique. The molecular scattered light from two small probe volumes of 1.03 mm length was measured for a completely non-intrusive means of determining the turbulent density fluctuations. The time series of density fluctuations were analyzed to estimate the integral length scale L in a moving frame of reference and the convective Mach number M(sub c) at different narrow Strouhal frequency (St) bands. It was observed that M(sub c) and the normalized moving frame length scale L*St/D, where D is the jet diameter, increased with Strouhal frequency before leveling off at the highest resolved frequency. Significant differences were observed between data obtained from the lip shear layer and the centerline of the jet. The wave number frequency transform of the correlation data demonstrated progressive increase in the radiative part of turbulence fluctuations with increasing jet Mach number.

  18. Variability in hematology of white-spotted bamboo sharks (Chiloscyllium plagiosum) in different living environments.

    PubMed

    Parkinson, Lily A; Alexander, Amy B; Campbell, Terry W

    2017-07-01

    Elasmobranch hematology continues to reveal new peculiarities within this specialized field. This report compares total hematologic values from the same white-spotted bamboo sharks (Chiloscyllium plagiosum) housed in different environments. We compared the hemograms one year apart, using a standardized Natt-Herrick's technique. The total white blood cell (WBC) counts of the sharks were statistically different between the two time points (initial median total WBC count = 18,920 leukocytes/μl, SD = 8,108; 1 year later total WBC count = 1,815 leukocytes/μl, SD = 1,309). The packed cell volumes were additionally found to be statistically different (19%, SD = 2.9 vs. 22%, SD = 2.0). Analysis revealed the only differences between the time points were the temperature and stocking densities at which these sharks were housed. This report emphasizes the need for a thorough understanding of the husbandry of an elasmobranch prior to interpretation of a hemogram and suggests that reference intervals should be created for each environment. © 2017 Wiley Periodicals, Inc.

  19. Reference ranges for cortisol and α-amylase in mother and newborn saliva samples at different perinatal and postnatal periods.

    PubMed

    García-Blanco, Ana; Vento, Máximo; Diago, Vicente; Cháfer-Pericás, Consuelo

    2016-06-01

    This paper describes a reliable analytical method based on Ultra High-Performance Liquid Chromatography coupled to tandem mass spectrometry to determine cortisol in saliva samples from healthy mothers (n=87) and newborns (n=65) at different time points: (i) 38 weeks of gestation, (ii) in the immediate postnatal period (48h) after a term delivery and, (iii) 3 months after delivery. The procedure is characterized by a simple sample treatment employing a sample volume of 25μL. In addition to this, salivary α-amylase was determined using a commercial kit. We have proposed potential reference ranges in saliva for cortisol (0.7-35nmolL(-1)) and α-amylase (2-500UmL(-1)) in mothers, and for cortisol (0.1-56nmolL(-1)) and α-amylase (0.1-500UmL(-1)) in newborn infants. In addition, statistical differences between the two sensitive population groups (mothers and newborns) at the perinatal and postnatal periods were studied. A lower concentration for maternal cortisol was found at 38 weeks of gestation than at 48h (p=0.048) or 3 months after delivery (p=0.021). Similar results were found for the α-amylase determinations. Hence, higher concentrations than could be expected from a chronic stress marker were found at 3 months after delivery than at 38 weeks of gestation (p<0.001) or 48h after delivery (p<0.001). We conclude that this analytical method could be applied to further clinical research on perinatal and postnatal stress, such as threatened preterm labor and/or parenting stress, respectively. Copyright © 2016 Elsevier B.V. All rights reserved.

  20. Effects of lead, cadmium, arsenic, and mercury co-exposure on children's intelligence quotient in an industrialized area of southern China.

    PubMed

    Pan, Shangxia; Lin, Lifeng; Zeng, Fan; Zhang, Jianpeng; Dong, Guanghui; Yang, Boyi; Jing, You; Chen, Shejun; Zhang, Gan; Yu, Zhiqiang; Sheng, Guoying; Ma, Huimin

    2018-04-01

    Exposure to metal(loid)s can lead to adverse effects on nervous system in children. However, little is known about the possible interaction effects of simultaneous exposure to multiple metal(loid)s on children's intelligence. In addition, relationship between blood lead concentrations (<100 μg/L) and the intelligence of children over 5 years needs further epidemiological evidence. We recruited 530 children aged 9-11 years, including 266 living in a town near an industrialized area and 264 from another town in the same city in South China as a reference. The levels of lead (Pb), cadmium (Cd), arsenic (As) and mercury (Hg) in blood (BPb, BCd, BAs, BHg) and urine (UPb, UCd, UAs, UHg) were assessed, as well as children's intelligence quotient (IQ). A significant decrease in IQ scores was identified in children from the industrialized town (p < .05), who had statistically higher geometric mean concentrations of BPb, BCd, UPb, UCd and UHg (65.89, 1.93, 4.04, 1.43 and 0.37 μg/L, respectively) compared with children from the reference town (37.21, 1.07, 2.14, 1.02 and 0.30 μg/L, respectively, p < .05). After adjusting confounders, only BPb had a significant negative association with IQ (B = -0.10, 95% confidence interval: -0.15 to -0.05, p < .001), which indicated that IQ decreased 0.10 points when BPb increased 1 μg/L. Significant negative interactions between BAs and BHg, positive interaction between UPb and UCd on IQ were observed (p < .10), and BPb <100 μg/L still negatively affected IQ (p < .05). Our findings suggest that although only BPb causes a decline in children's IQ when simultaneously exposed to these four metal(loid)s at relatively low levels, interactions between metal(loid)s on children's IQ should be paid special attention, and the reference standard in China of 100 μg/L BPb for children above 5 years old should be revised. Copyright © 2017 Elsevier Ltd. All rights reserved.

  1. 40 CFR 63.652 - Emissions averaging provisions.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... emissions average. This must include any Group 1 emission points to which the reference control technology... controls for a Group 1 emission point, the pollution prevention measure alone does not have to reduce... in control after November 15, 1990; (2) Group 1 emission points that are controlled by a reference...

  2. 40 CFR 63.652 - Emissions averaging provisions.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... emissions average. This must include any Group 1 emission points to which the reference control technology... controls for a Group 1 emission point, the pollution prevention measure alone does not have to reduce... in control after November 15, 1990; (2) Group 1 emission points that are controlled by a reference...

  3. A systematic review and meta-analysis of the diagnostic accuracy of point-of-care tests for the detection of hyperketonemia in dairy cows.

    PubMed

    Tatone, Elise H; Gordon, Jessica L; Hubbs, Jessie; LeBlanc, Stephen J; DeVries, Trevor J; Duffield, Todd F

    2016-08-01

    Several rapid tests for use on farm have been validated for the detection of hyperketonemia (HK) in dairy cattle, however the reported sensitivity and specificity of each method varies and no single study has compared them all. Meta-analysis of diagnostic test accuracy is becoming more common in human medical literature but there are few veterinary examples. The objective of this work was to perform a systematic review and meta-analysis to determine the point-of-care testing method with the highest combined sensitivity and specificity, the optimal threshold for each method, and to identify gaps in the literature. A comprehensive literature search resulted in 5196 references. After removing duplicates and performing relevance screening, 23 studies were included for the qualitative synthesis and 18 for the meta-analysis. The three index tests evaluated in the meta-analysis were: the Precision Xtra(®) handheld device measuring beta-hydroxybutyrate (BHB) concentration in whole blood, and Ketostix(®) and KetoTest(®) semi-quantitative strips measuring the concentration of acetoacetate in urine and BHB in milk, respectively. The diagnostic accuracy of the 3 index tests relative to the reference standard measurement of BHB in serum or whole blood between 1.0-1.4mmol/L was compared using the hierarchical summary receiver operator characteristic (HSROC) method. Subgroup analysis was conducted for each index test to examine the accuracy at different thresholds. The impact of the reference standard threshold, the reference standard method, the prevalence of HK in the population, the primary study source and risk of bias of the primary study was explored using meta-regression. The Precision Xtra(®) device had the highest summary sensitivity in whole blood BHB at 1.2mmol/L, 94.8% (CI95%: 92.6-97.0), and specificity, 97.5% (CI95%: 96.9-98.1). The threshold employed (1.2-1.4mmol/L) did not impact the diagnostic accuracy of the test. The Ketostix(®) and KetoTest(®) strips had the highest summary sensitivity and specificity when the trace and weak positive thresholds were used, respectively. Controlling for the source of publication, HK prevalence and reference standard employed did not impact the estimated sensitivity and specificity of the tests. Including only peer-reviewed studies reduced the number of primary studies evaluating the Precision Xtra(®) by 43% and Ketostix(®) by 33%. Diagnosing HK with blood, urine or milk are valid options, however, the diagnostic inaccuracy of urine and milk should be considered when making economic and treatment decisions. Copyright © 2016 Elsevier B.V. All rights reserved.

  4. Evaluation of the Water Film Weber Number in Glaze Icing Scaling

    NASA Technical Reports Server (NTRS)

    Tsao, Jen-Ching; Kreeger, Richard E.; Feo, Alejandro

    2010-01-01

    Icing scaling tests were performed in the NASA Glenn Icing Research Tunnel to evaluate a new scaling method, developed and proposed by Feo for glaze icing, in which the scale liquid water content and velocity were found by matching reference and scale values of the nondimensional water-film thickness expression and the film Weber number. For comparison purpose, tests were also conducted using the constant We(sub L) method for velocity scaling. The reference tests used a full-span, fiberglass, 91.4-cm-chord NACA 0012 model with velocities of 76 and 100 knot and MVD sizes of 150 and 195 microns. Scale-to-reference model size ratio was 1:2.6. All tests were made at 0deg AOA. Results will be presented for stagnation point freezing fractions of 0.3 and 0.5.

  5. The inner zone electron model AE-5

    NASA Technical Reports Server (NTRS)

    Teague, M. J.; Vette, J. I.

    1972-01-01

    A description is given of the work performed in the development of the inner radiation zone electron model, AE-5. A complete description of the omnidirectional flux model is given for energy thresholds E sub T in the range 4.0 E sub T/(MeV) 0.04 and for L values in the range 2.8 L 1.2 for an epoch of October 1967. Confidence codes for certain regions of B-L space and certain energies are given based on data coverage and the assumptions made in the analysis. The electron model programs that can be supplied to a user are referred to. One of these, a program for accessing the model flux at arbitrary points in B-L space and arbitrary energies, includes the latest outer zone electron model and proton model. The model AE-5, is based on data from five satellites, OGO 1, OGO 3, 1963-38C, OV3-3, and Explorer 26, spanning the period December 1964 to December 1967.

  6. The Influence of the Tri-reference Points on Fairness and Satisfaction Perception

    PubMed Central

    Zhao, Lei; Ye, Junhui; Wu, Xuexian; Hu, Fengpei

    2018-01-01

    We examined the influence of three reference points (minimum requirements [MR], the status quo [SQ], and goal [G]) proposed by the tri-reference point (TRP) theory on fairness and satisfaction perceptions of pay in three laboratory experiments. To test the effects, we manipulated these three reference points both implicitly (Experiment 1) and explicitly (Experiments 2 and 3). We also provided the information of the salary offered to a peer person that was lower than, equal to, or higher than the salary offer to the participant. As hypothesized, the results demonstrated the important role of these reference points in judging the fairness of and satisfaction with pay when they were explicitly set (an interaction between reference points and social comparison in Experiments 2 and 3, but not in Experiment 1). Participants altered their judgments when the salary was in different regions. When the salary was below MR, participants perceived very low fairness and satisfaction, even when the offer was equal to/exceeded others. When the salary was above G, participants perceived much higher fairness and satisfaction, even with disadvantageous inequality. Participants were more impacted when they were explicitly instructed of the reference points (Experiments 2 and 3) than when they were not (Experiment 1). Moreover, MR appeared to be the most important, followed by G. A Salary below MR was judged as very unacceptable, with very low fairness and satisfaction ratings. PMID:29515503

  7. Pharmacokinetics and bioequivalence of two strontium ranelate formulations after single oral administration in healthy Chinese subjects.

    PubMed

    Zhang, Dan; Du, Aihua; Wang, Xiaolin; Zhang, Lina; Yang, Man; Ma, Jingyi; Deng, Ming; Liu, Huichen

    2018-05-08

    Pharmacokinetics of exogenous strontium (Sr) and bioequivalence of a new oral formulation of strontium ranelate compared with the brand-name drug in healthy Chinese subjects was evaluated. A balanced, randomized, single-dose, two-treatment parallel study was conducted in 36 healthy Chinese subjects. Subjects were randomly allocated into two groups of 18 to receive a single oral dose of test formulation and reference formulation under a fasting state, respectively. Blood samples were collected at 19 designated time points up to 240-h post-dose. Serum concentrations of Sr were quantified by ICP-MS. A total of 36 subjects were enrolled and completed the study. Nine mild adverse events in 6 subjects were reported. The C max , AUC 0-72 h , AUC 0- t , and AUC 0-∞ of test and reference formulations shown as mean ± SD were 6.97 ± 1.78 and 6.78 ± 1.80 µg/mL, 199 ± 51 and 187 ± 38 µg·h/mL, 303 ± 89 and 278 ± 54 µg·h/mL, and 337 ± 109 and 305 ± 60 µg·h/mL, respectively. Two formulations were bioequivalent, and both were generally well tolerated.

  8. Investigation of L-band shipboard antennas for maritime satellite applications

    NASA Technical Reports Server (NTRS)

    Heckert, G. P.

    1972-01-01

    A basic conceptual investigation of low cost L-band antenna subsystems for shipboard use was conducted by identifying the various pertinent design trade-offs and related performance characteristics peculiar to the civilian maritime application, and by comparing alternate approaches for their simplicity and general suitability. The study was not directed at a single specific proposal, but was intended to be parametric in nature. Antenna system concepts were to be investigated for a range of gain of 3 to 18 dB, with a value of about 10 dB considered as a baseline reference. As the primary source of potential complexity in shipboard antennas, which have beamwidths less than hemispherical as the beam pointing or selecting mechanism, major emphasis was directed at this aspect. Three categories of antenna system concepts were identified: (1) mechanically pointed, single-beam antennas; (2) fixed antennas with switched-beams; and (3) electronically-steered phased arrays. It is recommended that an L-band short backfire antenna subsystem, including a two-axis motor driven gimbal mount, and necessary single channel monopulse tracking receiver portions be developed for demonstration of performance and subsystem simplicity.

  9. Age- and sex-specific reference limits for creatinine, cystatin C and the estimated glomerular filtration rate.

    PubMed

    Hannemann, Anke; Friedrich, Nele; Dittmann, Kathleen; Spielhagen, Christin; Wallaschofski, Henri; Völzke, Henry; Rettig, Rainer; Endlich, Karlhans; Lendeckel, Uwe; Stracke, Sylvia; Nauck, Matthias

    2011-11-14

    Early detection of patients with chronic kidney disease is of great importance. This study developed reference limits for serum creatinine and serum cystatin C concentrations and for the estimated glomerular filtration rate (eGFR) in healthy subjects from the general population aged 25-65 years. This study defined a reference population including 985 subjects from the first follow-up of the Study of Health in Pomerania. Serum creatinine was measured with a modified kinetic Jaffé method. Serum cystatin C was measured with a nephelometric assay. The eGFR was calculated from serum creatinine according to the Cockcroft-Gault (eGFR(CG)) and the Modification of Diet in Renal Disease (eGFR(MDRD)) equation, respectively, as well as from serum cystatin C according to the formula by Larsson (eGFR(Larsson)). Non-parametric quantile regression was used to estimate the reference limits. For serum creatinine and serum cystatin C the 95th percentile and for eGFR(CG), eGFR(MDRD) and eGFR(Larsson) the 5th percentile were selected as reference limits. All data was weighted to reflect the age- and sex-structure of the German population in 2008. The reference limits for serum creatinine (men: 1.11-1.23 mg/dL; women: 0.93-1.00 mg/dL) and serum cystatin C levels (men: 0.92-1.04 mg/L; women: 0.84-1.02 mg/L) increased with advancing age. The reference limits for eGFR decreased with increasing age (eGFR(CG) men: 106.0-64.7 mL/min, women 84.4-57.9 mL/min; eGFR(MDRD) men: 82.5-62.2 mL/min/1.73 m², women 75.0-58.2 mL/min/1.73 m²; eGFR(Larsson) men: 85.5-72.9 mL/min, women 94.5-75.7 mL/min). This study presents age- and sex-specific reference limits for five measures of renal function based on quantile regression models.

  10. Numerical and In Vitro Experimental Investigation of the Hemolytic Performance at the Off-Design Point of an Axial Ventricular Assist Pump.

    PubMed

    Liu, Guang-Mao; Jin, Dong-Hai; Jiang, Xi-Hang; Zhou, Jian-Ye; Zhang, Yan; Chen, Hai-Bo; Hu, Sheng-Shou; Gui, Xing-Min

    The ventricular assist pumps do not always function at the design point; instead, these pumps may operate at unfavorable off-design points. For example, the axial ventricular assist pump FW-2, in which the design point is 5 L/min flow rate against 100 mm Hg pressure increase at 8,000 rpm, sometimes works at off-design flow rates of 1 to 4 L/min. The hemolytic performance of the FW-2 at both the design point and at off-design points was estimated numerically and tested in vitro. Flow characteristics in the pump were numerically simulated and analyzed with special attention paid to the scalar sheer stress and exposure time. An in vitro hemolysis test was conducted to verify the numerical results. The simulation results showed that the scalar shear stress in the rotor region at the 1 L/min off-design point was 70% greater than at the 5 L/min design point. The hemolysis index at the 1 L/min off-design point was 3.6 times greater than at the 5 L/min design point. The in vitro results showed that the normalized index of hemolysis increased from 0.017 g/100 L at the 5 L/min design point to 0.162 g/100 L at the 1 L/min off-design point. The hemolysis comparison between the different blood pump flow rates will be helpful for future pump design point selection and will guide the usage of ventricular assist pumps. The hemolytic performance of the blood pump at the working point in the clinic should receive more focus.

  11. Effect of Harm Anchors in Visual Displays of Test Results on Patient Perceptions of Urgency About Near-Normal Values: Experimental Study.

    PubMed

    Zikmund-Fisher, Brian J; Scherer, Aaron M; Witteman, Holly O; Solomon, Jacob B; Exe, Nicole L; Fagerlin, Angela

    2018-03-26

    Patient-facing displays of laboratory test results typically provide patients with one reference point (the "standard range"). To test the effect of including an additional harm anchor reference point in visual displays of laboratory test results, which indicates how far outside of the standard range values would need to be in order to suggest substantial patient risk. Using a demographically diverse, online sample, we compared the reactions of 1618 adults in the United States who viewed visual line displays that included both standard range and harm anchor reference points ("Many doctors are not concerned until here") to displays that included either (1) only a standard range, (2) standard range plus evaluative categories (eg, "borderline high"), or (3) a color gradient showing degree of deviation from the standard range. Providing the harm anchor reference point significantly reduced perceived urgency of close-to-normal alanine aminotransferase and creatinine results (P values <.001) but not generally for platelet count results. Notably, display type did not significantly alter perceptions of more extreme results in potentially harmful ranges. Harm anchors also substantially reduced the number of participants who wanted to contact their doctor urgently or go to the hospital about these test results. Presenting patients with evaluative cues regarding when test results become clinically concerning can reduce the perceived urgency of out-of-range results that do not require immediate clinical action. ©Brian J Zikmund-Fisher, Aaron M Scherer, Holly O Witteman, Jacob B Solomon, Nicole L Exe, Angela Fagerlin. Originally published in the Journal of Medical Internet Research (http://www.jmir.org), 26.03.2018.

  12. Seven-Year Clinical Surveillance Program Demonstrates Consistent MARD Accuracy Performance of a Blood Glucose Test Strip.

    PubMed

    Setford, Steven; Grady, Mike; Mackintosh, Stephen; Donald, Robert; Levy, Brian

    2018-05-01

    MARD (mean absolute relative difference) is increasingly used to describe performance of glucose monitoring systems, providing a single-value quantitative measure of accuracy and allowing comparisons between different monitoring systems. This study reports MARDs for the OneTouch Verio® glucose meter clinical data set of 80 258 data points (671 individual batches) gathered as part of a 7.5-year self-surveillance program Methods: Test strips were routinely sampled from randomly selected manufacturer's production batches and sent to one of 3 clinic sites for clinical accuracy assessment using fresh capillary blood from patients with diabetes, using both the meter system and standard laboratory reference instrument. Evaluation of the distribution of strip batch MARD yielded a mean value of 5.05% (range: 3.68-6.43% at ±1.96 standard deviations from mean). The overall MARD for all clinic data points (N = 80 258) was also 5.05%, while a mean bias of 1.28 was recorded. MARD by glucose level was found to be consistent, yielding a maximum value of 4.81% at higher glucose (≥100 mg/dL) and a mean absolute difference (MAD) of 5.60 mg/dL at low glucose (<100 mg/dL). MARD by year of manufacture varied from 4.67-5.42% indicating consistent accuracy performance over the surveillance period. This 7.5-year surveillance program showed that this meter system exhibits consistently low MARD by batch, glucose level and year, indicating close agreement with established reference methods whilste exhibiting lower MARD values than continuous glucose monitoring (CGM) systems and providing users with confidence in the performance when transitioning to each new strip batch.

  13. Reference-point-independent dynamics of molecular liquids and glasses in the tensorial formalism

    NASA Astrophysics Data System (ADS)

    Schilling, Rolf

    2002-05-01

    We apply the tensorial formalism to the dynamics of molecular liquids and glasses. This formalism separates the degrees of freedom into translational and orientational ones. Using the Mori-Zwanzig projection formalism, the equations of motion for the tensorial density correlators Slmn,l'm'n'(q-->,t) are derived. For this we show how to choose the slow variables such that the resulting Mori-Zwanzig equations are covariant under a change of the reference point of the body fixed frame. We also prove that the memory kernels obtained from mode-coupling theory (MCT) including all approximations preserve the covariance. This covariance makes, e.g., the glass transition point, the two universal scaling laws and particularly the corresponding exponents independent on the reference point and on the mass and moments of inertia, i.e., they only depend on the properties of the potential energy landscape. Finally, we show that the corresponding MCT questions for linear molecules can be obtained from those for arbitrary molecules and that they differ from earlier equations that are not covariant.

  14. Determination of the carbon, hydrogen and nitrogen contents of alanine and their uncertainties using the certified reference material L-alanine (NMIJ CRM 6011-a).

    PubMed

    Itoh, Nobuyasu; Sato, Ayako; Yamazaki, Taichi; Numata, Masahiko; Takatsu, Akiko

    2013-01-01

    The carbon, hydrogen, and nitrogen (CHN) contents of alanine and their uncertainties were estimated using a CHN analyzer and the certified reference material (CRM) L-alanine. The CHN contents and their uncertainties, as measured using the single-point calibration method, were 40.36 ± 0.20% for C, 7.86 ± 0.13% for H, and 15.66 ± 0.09% for N; the results obtained using the bracket calibration method were also comparable. The method described in this study is reasonable, convenient, and meets the general requirement of having uncertainties ≤ 0.4%.

  15. Pharmacokinetic evaluation of a newly developed piperazine dithioctate formulation in healthy volunteers.

    PubMed

    Zheng, Renhua; Song, Hyung Ho; Kwon, Young Ee; Kim, Bo-Hyung

    2014-12-01

    The formulation investigated as reference contains thioctic acid which is known to be poorly soluble in water and have some instability during storage at high temperature. To overcome these limitations, a new piperazine dithioctate (PDT) tablet formulation was developed by a domestic pharmaceutical company in Korea. The aim of this clinical study was to evaluate the pharmacokinetic characteristics of PDT in healthy volunteers. This study consisted of two clinical trials. In the part 1 study, a randomized, singledose, parallel study was performed with 24 healthy volunteers. All of the subjects were administered one of the three study formulations, Thioctacid® HR (High Release) as the reference, PDT-1 or PDT-2 (each containing thioctic acid 600 mg), respectively. To determine the harmacokinetic characteristics, blood samples were serially collected at pre-dose and at pre-defined timepoints after dosing. In the part 2 study, a randomized, single-dose, two-way crossover study was conducted with 48 subjects. All of the subjects were administered both the reference and PDT-2 formulations, with a 7-day washout period between the two medications. Blood samples were collected at the same timepoints as in the part 1 study. Tolerability was evaluated throughout the study. 23 volunteers completed the part 1 study. The maximum plasma concentration (Cmax) of thioctic acid after administration of the reference tablet was 4.08 ± 2.35 μg/mL (means ± SD), and the Cmax of PDT-1 and PDT-2 was 3.53 ± 2.87 μg/mL and 4.15 ± 1.62 μg/mL, respectively. The AUClast value was 2.96 ± 1.13 μg x h/mL for the reference, 2.84 ± 1.12 μg x h/mL for PDT-1, and 3.30 ± 1.32 μg x h/mL for PDT-2. 42 volunteers completed the part 2 study. The Cmax of reference and PDT-2 was 5.59 ± 3.07 μg/mL and 5.14 ± 3.18 μg/mL, respectively. The AUClast value was 4.01 ± 1.65 μg x h/mL for the reference and 3.96 ± 1.47 μg x h/mL for PDT-2. The geometric mean ratios (PDT-2/reference) and the 90% CI for Cmax and AUClast were 0.93 (0.78 - 1.11) and 1.01 (0.94 - 1.09), respectively. Both studies suggested that the pharmacokinetic profile of the newly developed piperazine dithioctate formulation was comparable to the pharmacokinetic profile of the reference tablet. Both study tablets were well tolerated in all of the subjects.

  16. Accuracy of body mass index for age to diagnose obesity in Mexican schoolchildren.

    PubMed

    Mendoza Pablo, Pedro A; Valdés, Jesús; Ortiz-Hernández, Luis

    2015-06-01

    To compare the accuracy of three BMI-forage references (World Health Organization reference, WHO; the updated International Obesity Task Force reference, IOTF; and Centers for Disease Control and Prevention (CDC) growth charts) to diagnose obesity in Mexican children. A convenience sample of Mexican schoolchildren (n = 218) was assessed. The gold standard was the percentage of body fat estimated by deuterium dilution technique. Sensitivity and specificity of the classical cutoff point of BMI-for-age to identify obesity (i.e. > 2.00 standard deviation, SD) were estimated. The accuracy (i.e. area under the curve, AUC) of three BMI-for-age references for the diagnosis of obesity was estimated with the receiver operating characteristic (ROC) curves method. The optimal cutoff point (OCP) was determined. The cutoff points to identify obesity had low (WHO reference: 57.6%, CDC: 53.5%) to very low (IOTF reference: 40.4%) sensitivities, but adequate specificities (91.6%, 95.0%, and, 97.5%, respectively). The AUC of the three references were adequate (0.89). For the IOTF reference, the AUC was lower among the older children. The OCP for the CDC reference (1.24 SD) was lower than the OCP for WHO (1.53 SD) and IOTF charts (1.47 SD). The classical cutoff point for obesity has low sensitivity--especially for the IOTF reference. The accuracy of the three references was similar. However, to obtain comparable diagnosis of obesity different cutoff points should be used depending of the reference. Copyright AULA MEDICA EDICIONES 2014. Published by AULA MEDICA. All rights reserved.

  17. Long term effects of extended adjuvant endocrine therapy on quality of life in breast cancer patients.

    PubMed

    Kool, M; Fontein, D B Y; Meershoek-Klein Kranenbarg, E; Nortier, J W R; Rutgers, E J T; Marang-van de Mheen, P J; van de Velde, C J H

    2015-06-01

    The standard treatment for hormone-receptor positive, postmenopausal early breast cancer patients is 5 years of adjuvant endocrine therapy. Previous studies demonstrate that prolonging adjuvant endocrine therapy may improve disease-free survival. However, endocrine therapy is known for its adverse events, which may negatively affect Quality of Life (QoL). The aim of this study is to assess the impact of extended adjuvant endocrine therapy on long-term QoL outcomes. 471 patients selected from the IDEAL trial were invited to complete a questionnaire 1-1.5 years after starting with extended therapy. The questionnaire consisted of the EORTC QLQ-C30 and QLQ-BR23 questionnaires. Mean QoL outcomes were compared with EORTC reference values for stage I and II breast cancer patients and the general population. Furthermore, QoL outcomes were compared between different treatment regimens. A difference of eight points was considered clinically relevant. IDEAL patients receiving extended adjuvant endocrine therapy have significantly and clinically relevant better global QoL compared with reference values for stage I and II breast cancer patients (79.6 versus 64.6; p < 0.01) and the general population (79.6 versus 71.2; p < 0.01). Similar results were found for emotional function, pain, appetite loss, diarrhea and financial problems. Between treatment regimens prior to extended adjuvant endocrine therapy, differences were only found on specific QoL domains (e.g. arm symptoms). Breast cancer patients on extended adjuvant endocrine therapy have significantly and clinically relevant better global QoL compared with other stage I-II breast cancer patients and the general population, 6-8.5 years after diagnosis. Copyright © 2015 Elsevier Ltd. All rights reserved.

  18. Cross-reactions between Legionella pneumophila (serogroup 1) and twenty-eight other bacterial species, including other members of the family Legionellaceae.

    PubMed Central

    Collins, M T; Espersen, F; Høiby, N; Cho, S N; Friis-Møller, A; Reif, J S

    1983-01-01

    Cross-reactions between Legionella pneumophila serogroup 1 and 28 other bacterial species were studied by various quantitative immunoelectrophoretic techniques. A sonicated L. pneumophila antigen and purified homologous rabbit antibody were used as a reference system. Few antigens (0 to 6) cross-reacted with non-Legionellaceae, but two were found in nearly all gram-negative bacteria tested (antigens no. 1 and 66). Antigen no. 66 of the L. pneumophila reference system was shown to be antigenically similar to the "common antigen" of Pseudomonas aeruginosa reported in many gram-negative bacteria. Greater than 85% of the antigens from L. pneumophila serogroup 1 cross-reacted with the other six serogroups of L. pneumophila. By contrast, Fluoribacter (Legionella) bozemanae, F. (L.) dumoffii, F. (L.) gormanii, and Tatlockia (Legionella) micdadei cross-reacted with only 45, 53, 39, and 43% of the reference system antigens, respectively. The antigenic relatedness of members of the Legionellaceae, expressed as a matching coefficient, is discussed in terms of its taxonomic significance. Serogroup-, genus-, and family-specific antigens are identified in the L. pneumophila reference system. Images PMID:6404825

  19. Reference intervals for selected serum biochemistry analytes in cheetahs Acinonyx jubatus.

    PubMed

    Hudson-Lamb, Gavin C; Schoeman, Johan P; Hooijberg, Emma H; Heinrich, Sonja K; Tordiffe, Adrian S W

    2016-02-26

    Published haematologic and serum biochemistry reference intervals are very scarce for captive cheetahs and even more for free-ranging cheetahs. The current study was performed to establish reference intervals for selected serum biochemistry analytes in cheetahs. Baseline serum biochemistry analytes were analysed from 66 healthy Namibian cheetahs. Samples were collected from 30 captive cheetahs at the AfriCat Foundation and 36 free-ranging cheetahs from central Namibia. The effects of captivity-status, age, sex and haemolysis score on the tested serum analytes were investigated. The biochemistry analytes that were measured were sodium, potassium, magnesium, chloride, urea and creatinine. The 90% confidence interval of the reference limits was obtained using the non-parametric bootstrap method. Reference intervals were preferentially determined by the non-parametric method and were as follows: sodium (128 mmol/L - 166 mmol/L), potassium (3.9 mmol/L - 5.2 mmol/L), magnesium (0.8 mmol/L - 1.2 mmol/L), chloride (97 mmol/L - 130 mmol/L), urea (8.2 mmol/L - 25.1 mmol/L) and creatinine (88 µmol/L - 288 µmol/L). Reference intervals from the current study were compared with International Species Information System values for cheetahs and found to be narrower. Moreover, age, sex and haemolysis score had no significant effect on the serum analytes in this study. Separate reference intervals for captive and free-ranging cheetahs were also determined. Captive cheetahs had higher urea values, most likely due to dietary factors. This study is the first to establish reference intervals for serum biochemistry analytes in cheetahs according to international guidelines. These results can be used for future health and disease assessments in both captive and free-ranging cheetahs.

  20. Spacecraft Maneuvering at the Sun/Earth-Moon L2 Libration Point

    NASA Astrophysics Data System (ADS)

    Shahid, Kamran

    Spacecraft formation flying in the vicinity of the Sun/Earth-Moon libration points offers many promising possibilities for space exploration. The concept of formation flying involves the distribution of the functionality of a single spacecraft among several smaller, cooperative spacecraft. The libration points are locations relative to two large orbiting bodies where a third body with relatively small mass can remain stationary relative to the two larger bodies. The most significant perturbation experienced by a spacecraft at the libration point is effect of solar radiation pressure. This thesis presents the development of nonlinear control techniques for maneuvering control at the Sun-Earth/Moon L2 libration point. A new thruster based formation control technique is presented. We also consider a leader/follower formation architecture, and examine the station keeping control of the leader spacecraft and the formation control of the follower spacecraft using solar radiation pressure. Reference trajectories of the leader spacecraft, halo and Lissajous orbits, are determined using a numerical technique in order to take into account all major gravitational perturbations. The nonlinear controllers are developed based on Lyapunov analysis, including non-adaptive and adaptive designs. Thruster based and solar radiation pressure based control laws for spacecraft maneuvering at the Sun-Earth/Moon libration point are developed. Higher order sliding mode control is utilized to address the non-affine structure of the solar sail control inputs. The reduced input solar radiation pressure problem is properly addressed as an underactuated control problem. The development of adaptive control for solar sail equipped spacecraft is an innovation and represents and advancement in solar sailing control technology. Controller performance is evaluated in a high fidelity ephemeris model to reflect a realistic simulated space environment. The numerical results demonstrate the effectiveness of the proposed control techniques for spacecraft maneuvering using solar radiation pressure at the L2 libration point. Stationkeeping accuracies of 50m and formation maintenance accuracies of less than 1m are possible using solar radiation pressure at a sub-L2 libration point. The benefits of these control techniques include increasing libration point mission lifetimes and doubling payload mass fractions as compared to conventional propulsion methods.

  1. Development of a simple, sensitive and inexpensive ion-pairing cloud point extraction approach for the determination of trace inorganic arsenic species in spring water, beverage and rice samples by UV-Vis spectrophotometry.

    PubMed

    Gürkan, Ramazan; Kır, Ufuk; Altunay, Nail

    2015-08-01

    The determination of inorganic arsenic species in water, beverages and foods become crucial in recent years, because arsenic species are considered carcinogenic and found at high concentrations in the samples. This communication describes a new cloud-point extraction (CPE) method for the determination of low quantity of arsenic species in the samples, purchased from the local market by UV-Visible Spectrophotometer (UV-Vis). The method is based on selective ternary complex of As(V) with acridine orange (AOH(+)) being a versatile fluorescence cationic dye in presence of tartaric acid and polyethylene glycol tert-octylphenyl ether (Triton X-114) at pH 5.0. Under the optimized conditions, a preconcentration factor of 65 and detection limit (3S blank/m) of 1.14 μg L(-1) was obtained from the calibration curve constructed in the range of 4-450 μg L(-1) with a correlation coefficient of 0.9932 for As(V). The method is validated by the analysis of certified reference materials (CRMs). Copyright © 2015 Elsevier Ltd. All rights reserved.

  2. Embodiment and second-language: automatic activation of motor responses during processing spatially associated L2 words and emotion L2 words in a vertical Stroop paradigm.

    PubMed

    Dudschig, Carolin; de la Vega, Irmgard; Kaup, Barbara

    2014-05-01

    Converging evidence suggests that understanding our first-language (L1) results in reactivation of experiential sensorimotor traces in the brain. Surprisingly, little is known regarding the involvement of these processes during second-language (L2) processing. Participants saw L1 or L2 words referring to entities with a typical location (e.g., star, mole) (Experiment 1 & 2) or to an emotion (e.g., happy, sad) (Experiment 3). Participants responded to the words' ink color with an upward or downward arm movement. Despite word meaning being fully task-irrelevant, L2 automatically activated motor responses similar to L1 even when L2 was acquired rather late in life (age >11). Specifically, words such as star facilitated upward, and words such as root facilitated downward responses. Additionally, words referring to positive emotions facilitated upward, and words referring to negative emotions facilitated downward responses. In summary our study suggests that reactivation of experiential traces is not limited to L1 processing. Copyright © 2014 Elsevier Inc. All rights reserved.

  3. The performance of flash glucose monitoring in critically ill patients with diabetes.

    PubMed

    Ancona, Paolo; Eastwood, Glenn M; Lucchetta, Luca; Ekinci, Elif I; Bellomo, Rinaldo; Mårtensson, Johan

    2017-06-01

    Frequent glucose monitoring may improve glycaemic control in critically ill patients with diabetes. We aimed to assess the accuracy of a novel subcutaneous flash glucose monitor (FreeStyle Libre [Abbott Diabetes Care]) in these patients. We applied the FreeStyle Libre sensor to the upper arm of eight patients with diabetes in the intensive care unit and obtained hourly flash glucose measurements. Duplicate recordings were obtained to assess test-retest reliability. The reference glucose level was measured in arterial or capillary blood. We determined numerical accuracy using Bland- Altman methods, the mean absolute relative difference (MARD) and whether the International Organization for Standardization (ISO) and Clinical and Laboratory Standards Institute Point of Care Testing (CLSI POCT) criteria were met. Clarke error grid (CEG) and surveillance error grid (SEG) analyses were used to determine clinical accuracy. We compared 484 duplicate flash glucose measurements and observed a Pearson correlation coefficient of 0.97 and a coefficient of repeatability of 1.6 mmol/L. We studied 185 flash readings paired with arterial glucose levels, and 89 paired with capillary glucose levels. Using the arterial glucose level as the reference, we found a mean bias of 1.4 mmol/L (limits of agreement, -1.7 to 4.5 mmol/L). The MARD was 14% (95% CI, 12%-16%) and the proportion of measurements meeting ISO and CLSI POCT criteria was 64.3% and 56.8%, respectively. The proportions of values within a low-risk zone on CEG and SEG analyses were 97.8% and 99.5%, respectively. Using capillary glucose levels as the reference, we found that numerical and clinical accuracy were lower. The subcutaneous FreeStyle Libre blood glucose measurement system showed high test-retest reliability and acceptable accuracy when compared with arterial blood glucose measurement in critically ill patients with diabetes.

  4. Comparative study of an argon plasma and an argon copper plasma produced by an ICP torch at atmospheric pressure based on spectroscopic methods

    NASA Astrophysics Data System (ADS)

    Bussière, W.; Vacher, D.; Menecier, S.; André, P.

    2012-04-01

    In three places in this paper, the citation of reference [43] quotes a further reference [61] cited therein. This in fact should be the reference [45] cited in [43]. This occurs in the caption of figure 3; at the top of the right-hand column on page 6; and in the paragraph headed Influence of the Biberman factor value on page 18. In each case, the text: '[43] (especially reference [61] therein)' should be replaced by '[43] (especially reference [45] therein)'. The authors would like to thank Dr L G D'yachkov for having pointed out the error.

  5. Field assessment of dried Plasmodium falciparum samples for malaria rapid diagnostic test quality control and proficiency testing in Ethiopia.

    PubMed

    Tamiru, Afework; Boulanger, Lucy; Chang, Michelle A; Malone, Joseph L; Aidoo, Michael

    2015-01-21

    Rapid diagnostic tests (RDTs) are now widely used for laboratory confirmation of suspected malaria cases to comply with the World Health Organization recommendation for universal testing before treatment. However, many malaria programmes lack quality control (QC) processes to assess RDT use under field conditions. Prior research showed the feasibility of using the dried tube specimen (DTS) method for preserving Plasmodium falciparum parasites for use as QC samples for RDTs. This study focused on the use of DTS for RDT QC and proficiency testing under field conditions. DTS were prepared using cultured P. falciparum at densities of 500 and 1,000 parasites/μL; 50 μL aliquots of these along with parasite negative human blood controls (0 parasites/μL) were air-dried in specimen tubes and reactivity verified after rehydration. The DTS were used in a field study in the Oromia Region of Ethiopia. Replicate DTS samples containing 0, 500 and 1,000 parasites/μL were stored at 4°C at a reference laboratory and at ambient temperatures at two nearby health facilities. At weeks 0, 4, 8, 12, 16, 20, and 24, the DTS were rehydrated and tested on RDTs stored under manufacturer-recommended temperatures at the RL and on RDTs stored under site-specific conditions at the two health facilities. Reactivity of DTS stored at 4°C at the reference laboratory on RDTs stored at the reference laboratory was considered the gold standard for assessing DTS stability. A proficiency-testing panel consisting of one negative and three positive samples, monitored with a checklist was administered at weeks 12 and 24. At all the seven time points, DTS stored at both the reference laboratory and health facility were reactive on RDTs stored under the recommended temperature and under field conditions, and the DTS without malaria parasites were negative. At the reference laboratory and one health facility, a 500 parasites/μL DTS from the proficiency panel was falsely reported as negative at week 24 due to errors in interpreting faint test lines. The DTS method can be used under field conditions to supplement other RDT QC methods and health worker proficiency in Ethiopia and possibly other malaria-endemic countries.

  6. Preconcentration and determination of vanadium and molybdenum in milk, vegetables and foodstuffs by ultrasonic-thermostatic-assisted cloud point extraction coupled to flame atomic absorption spectrometry.

    PubMed

    Gürkan, Ramazan; Korkmaz, Sema; Altunay, Nail

    2016-08-01

    A new ultrasonic-thermostatic-assisted cloud point extraction procedure (UTA-CPE) was developed for preconcentration at the trace levels of vanadium (V) and molybdenum (Mo) in milk, vegetables and foodstuffs prior to determination via flame atomic absorption spectrometry (FAAS). The method is based on the ion-association of stable anionic oxalate complexes of V(V) and Mo(VI) with [9-(diethylamino)benzo[a]phenoxazin-5-ylidene]azanium; sulfate (Nile blue A) at pH 4.5, and then extraction of the formed ion-association complexes into micellar phase of polyoxyethylene(7.5)nonylphenyl ether (PONPE 7.5). The UTA-CPE is greatly simplified and accelerated compared to traditional cloud point extraction (CPE). The analytical parameters optimized are solution pH, the concentrations of complexing reagents (oxalate and Nile blue A), the PONPE 7.5 concentration, electrolyte concentration, sample volume, temperature and ultrasonic power. Under the optimum conditions, the calibration curves for Mo(VI) and V(V) are obtained in the concentration range of 3-340µgL(-1) and 5-250µgL(-1) with high sensitivity enhancement factors (EFs) of 145 and 115, respectively. The limits of detection (LODs) for Mo(VI) and V(V) are 0.86 and 1.55µgL(-1), respectively. The proposed method demonstrated good performances such as relative standard deviations (as RSD %) (≤3.5%) and spiked recoveries (95.7-102.3%). The accuracy of the method was assessed by analysis of two standard reference materials (SRMs) and recoveries of spiked solutions. The method was successfully applied into the determination of trace amounts of Mo(VI) and V(V) in milk, vegetables and foodstuffs with satisfactory results. Copyright © 2016 Elsevier B.V. All rights reserved.

  7. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gonzalez-Sprinberg, G; Piriz, G

    Purpose: To optimize the dose in bladder and rectum and show the different shapes of the isodose volumes in Co60-HDR brachytherapy, considering different utero and vaginal sources dwell ratio times (TU:TV). Methods: Besides Ir192-HDR, new Co60-HDR sources are being incorporated. We considered different TU:TV times and computed the dosis in bladder, rectum and at the reference points of the Manchester system. Also, we calculated the isodose volume and shape in each case. We used a EZAG-BEBIG Co0.A86 model with TPS HDRplus3.0.4. and LCT42-7, LCT42-2(R,L) applicators. A reference dose RA= 1.00 Gy was given to the A-right point. We considered themore » TU:TV dwell time ratios 1:0.25, 1:0.33, 1:0.5, 1:1, 1:2, 1:3, and 1:4. Given TU:TV, the stop time at each dwell position is fixed for each applicator. Results: Increasing TU:TV systematically results in a decreasing of the dose in bladder and rectum, e.g. 9% and 27% reduction were found in 1:0.25 with respect to 1:1, while 12% and 34% increase were found in 1:4 with respect to 1:1. Also, the isodose volume parameters height (h), width (w), thickness (t) and volume (hwt) increased from the 1:0.25 case to the 1:4 value: hwt is 25% lower and 31% higher than the 1:1 reference volume in these cases. Also w decreased for higher TU:TV and may compromise the tumoral volume coverage, decreasing 17% in the 1:0.25 case compared to the 1:1 case. The shape of the isodose volume was obtained for the different TU:TV considered. Conclusion: We obtained the shape of isodose volumes for different TU:TV values in gynecological Co60-HDR. We studied the dose reduction in bladder and rectum for different TU:TV ratios. The volume parameters and hwt are strongly dependent on this ratio. This information is useful for a quantitative check of the TPS and as a starting point towards optimization.« less

  8. A soluble biocompatible guanidine-containing polyamidoamine as promoter of primary brain cell adhesion and in vitro cell culturing

    NASA Astrophysics Data System (ADS)

    Tonna, Noemi; Bianco, Fabio; Matteoli, Michela; Cagnoli, Cinzia; Antonucci, Flavia; Manfredi, Amedea; Mauro, Nicolò; Ranucci, Elisabetta; Ferruti, Paolo

    2014-08-01

    This paper reports on a novel application of an amphoteric water-soluble polyamidoamine named AGMA1 bearing 4-butylguanidine pendants. AGMA1 is an amphoteric, prevailingly cationic polyelectrolyte with isoelectric point of about 10. At pH 7.4 it is zwitterionic with an average of 0.55 excess positive charges per unit, notwithstanding it is highly biocompatible. In this work, it was found that AGMA1 surface-adsorbed on cell culturing coverslips exhibits excellent properties as adhesion and proliferation promoter of primary brain cells such as microglia, as well as of hippocampal neurons and astrocytes. Microglia cells cultured on AGMA1-coated coverslips substrate displayed the typical resting, ramified morphology of those cultured on poly-L-lysine and poly-L-ornithine, employed as reference substrates. Mixed cultures of primary astrocytes and neuronal cells grown on AGMA1- and poly-L-lysine coated coverslips were morphologically undistinguishable. On both substrates, neurons differentiated axon and dendrites and eventually established perfectly functional synaptic contacts. Quantitative immunocytochemical staining revealed no difference between AGMA1 and poly-L-lysine. Electrophysiological experiments allowed recording neuron spontaneous activity on AGMA1. In addition, cell cultures on both AGMA1 and PLL displayed comparable excitatory and inhibitory neurotransmission, demonstrating that the synaptic contacts formed were fully functional.

  9. The error of L5/S1 joint moment calculation in a body-centered non-inertial reference frame when the fictitious force is ignored.

    PubMed

    Xu, Xu; Faber, Gert S; Kingma, Idsart; Chang, Chien-Chi; Hsiang, Simon M

    2013-07-26

    In ergonomics studies, linked segment models are commonly used for estimating dynamic L5/S1 joint moments during lifting tasks. The kinematics data input to these models are with respect to an arbitrary stationary reference frame. However, a body-centered reference frame, which is defined using the position and the orientation of human body segments, is sometimes used to conveniently identify the location of the load relative to the body. When a body-centered reference frame is moving with the body, it is a non-inertial reference frame and fictitious force exists. Directly applying a linked segment model to the kinematics data with respect to a body-centered non-inertial reference frame will ignore the effect of this fictitious force and introduce errors during L5/S1 moment estimation. In the current study, various lifting tasks were performed in the laboratory environment. The L5/S1 joint moments during the lifting tasks were calculated by a linked segment model with respect to a stationary reference frame and to a body-centered non-inertial reference frame. The results indicate that applying a linked segment model with respect to a body-centered non-inertial reference frame will result in overestimating the peak L5/S1 joint moments of the coronal plane, sagittal plane, and transverse plane during lifting tasks by 78%, 2%, and 59% on average, respectively. The instant when the peak moment occurred was delayed by 0.13, 0.03, and 0.09s on average, correspondingly for the three planes. The root-mean-square errors of the L5/S1 joint moment for the three planes are 21Nm, 19Nm, and 9Nm, correspondingly. Copyright © 2013 Elsevier Ltd. All rights reserved.

  10. Determination of hematology and plasma chemistry reference intervals for 3 populations of captive Atlantic sturgeon (Acipenser oxyrinchus oxyrinchus).

    PubMed

    Matsche, Mark A; Arnold, Jill; Jenkins, Erin; Townsend, Howard; Rosemary, Kevin

    2014-09-01

    The imperiled status of Atlantic sturgeon (Acipenser oxyrinchus oxyrinchus), a large, long-lived, anadromous fish found along the Atlantic coast of North America, has prompted efforts at captive propagation for research and stock enhancement. The purpose of this study was to establish hematology and plasma chemistry reference intervals of captive Atlantic sturgeon maintained under different culture conditions. Blood specimens were collected from a total of 119 fish at 3 hatcheries: Lamar, PA (n = 36, ages 10-14 years); Chalk Point, MD (n = 40, siblings of Lamar); and Horn Point, Cambridge, MD (n = 43, mixed population from Chesapeake Bay). Reference intervals (using robust techniques), median, mean, and standard deviations were determined for WBC, RBC, thrombocytes, PCV, HGB, MCV, MCH, MCHC, and absolute counts for lymphocytes (L), neutrophils (N), monocytes, and eosinophils. Chemistry analytes included concentrations of total proteins, albumin, glucose, urea, calcium, phosphate, sodium, potassium, chloride, and globulins, AST, CK, and LDH activities, and osmolality. Mean concentrations of total proteins, albumin, and glucose were at or below the analytic range. Statistical comparisons showed significant differences among hatcheries for each remaining plasma chemistry analyte and for PCV, RBC, MCHC, MCH, eosinophil and monocyte counts, and N:L ratio throughout all 3 groups. Therefore, reference intervals were calculated separately for each population. Reference intervals for fish maintained under differing conditions should be established per population. © 2014 American Society for Veterinary Clinical Pathology and European Society for Veterinary Clinical Pathology.

  11. Characterization of Ultra High Temperature Ceramics via Transmission Electron Microscopy. Part 2: UHTCs sintered with addition of TaSi2

    DTIC Science & Technology

    2010-01-21

    substituted by Hf in the TaSi2 phase, indicating that this silicide has a great solubility for the group IV metals . At the triple point junctions Ta5Si3...Mathis Müller for his precious help in TEM specimens’ preparations . FA8655-09-M-4002 40 References 1. L. E. Toth: Transition Metal Carbides and...Transition Metal Disilicides,’ Acta Mater., 44, 3035 (1996). 21. H. Pastor and R. Meyer: An Investigation of the Effect of Additions of Metal Silicides

  12. Determination of Selected Distillate Blending Solvents in Simple and Complex Aircraft Fuel Matrices Via Glass Capillary Gas Chromatography.

    DTIC Science & Technology

    1981-06-01

    Division OCT 1 5 1981 June 1981 B Final Report for Period January 1979 - December 1979 j Approved for Public Release; Distribution Unlimited.-I AERO...Solvent 2040 *2040 Blending Solvent Xylene Bottoms *Xylene Bottoms Blending Solvent *Reference: Gleason, C. C., Oller , T. L. Shayeson, M. W., and Bahr...Table 4) was realistic for a 0% by volume point, 17 AFWAL- TR-80-2082 U J & J 18, AFWAL-TR-80-2082 TABLE 4 PEAK AREA PERCENTAGES FOUND IN EACH UNIQUE

  13. Conditioning of renewable silver amalgam film electrode for the characterization of clothianidin and its determination in selected samples by adsorptive square-wave voltammetry.

    PubMed

    Brycht, Mariola; Skrzypek, Sławomira; Guzsvány, Valéria; Berenji, Janoš

    2013-12-15

    A new square-wave adsorptive stripping voltammetric (SWAdSV) method was developed for the determination of the neonicotinoid insecticide clothianidin (Clo), based on its reduction at a renewable silver amalgam film electrode (Hg(Ag)FE). The key point of the procedure is the pretreatment of the Hg(Ag)FE by applying the appropriate conditioning potential (-1.70 V vs. Ag/AgCl reference electrode). Under the optimized voltammetric conditions, such pretreatment resulted in the peak for the Clo reduction in Britton-Robinson buffer pH 9.0 at about -0.60 V, which was used for the analytical purpose. The developed SWAdSV procedure made it possible to determine Clo in the concentration range of 6.0×10(-7)-7.0×10(-6) mol L(-1) (LOD=1.8×10(-7) mol L(-1), LOQ=6.0×10(-7) mol L(-1)) and 7.0×10(-6)-4.0×10(-5) mol L(-1) (LOD=1.3×10(-6) mol L(-1), LOQ=4.2×10(-6) mol L(-1)). The repeatability, precision, and the recovery of the method were determined. The effect of common interfering pesticides was also investigated. Standard addition method was successfully applied and validated for the determination of Clo in spiked Warta River water, corn seeds samples, and in corn seeds samples treated with the commercial formulation PONCHO 600 FS. © 2013 Elsevier B.V. All rights reserved.

  14. Serum biochemical reference intervals for free-living Sand Tiger sharks (Carcharias taurus) from east Australian waters.

    PubMed

    Otway, Nicholas M

    2015-06-01

    Sharks are top-order predators in ocean food chains and the star attractions in aquaria worldwide. Unfortunately, blood biochemistry reference intervals (RI) have been determined for few species. The study aims to establish serum biochemical RI for free-living Sand Tiger sharks (Carcharias taurus) off eastern Australia. Thirty-seven sharks were captured and their sex, length, weight, reproductive maturity, and health status were recorded. After blood collection, serum analytes were quantified using standard analytical and statistical methods. Reference intervals, means, medians, and 90% confidence intervals were generated. Physiologic data from live and necropsied sharks were used to enhance the study results. Thirty healthy sharks were included in the study. Albumin could not be detected. With the exception of ALP activity, values were unaffected by sex, length, weight, age, and life-history stage. The means (RI) were: sodium 258 (249-267) mmol/L, potassium 5.0 (4.3-5.7) mmol/L, chloride 242 (227-257) mmol/L, inorganic phosphate 1.8 (1.7-2.0) mmol/L, total calcium 3.9 (3.3-4.4) mmol/L, magnesium 1.9 (1.6-2.2) mmol/L, glucose 2.7 (2.2-3.2) mmol/L, urea 377 (360-394) mmol/L, ALP 20 (8-31) U/L, ALT 3 U/L (no RI), AST 29 (13-45) U/L, CK 42 (5-79) U/L, total protein 30 (24-36) g/L, triglyceride 0.3 (0.1-0.6) mmol/L, cholesterol 1.4 (0.9-2.1) mmol/L, creatinine 32 μmol/L (no RI), total bilirubin 1.5 μmol/L (no RI), and osmolarity 1082 (1027-1136) mmol/L. These preliminary RI will assist with the clinical evaluation and treatment of captive and free-living Sand Tiger sharks worldwide. Studies with more animals will increase the precision of upper and lower reference limits. © 2015 American Society for Veterinary Clinical Pathology.

  15. Implications of false positive serology of Toxoplasma gondii in a pre-transplant patient.

    PubMed

    Beal, Stacy; Racsa, Lori; Alatoom, Adnan

    2014-01-01

    A 21-year-old white male with cystic fibrosis. Pre-transplant workup in preparation for bilateral lung transplant. Cystic fibrosis diagnosed at age 3, onset of insulin-dependent diabetes around age 20, and multiple hospitalizations for pulmonary and gastrointestinal complications. FAMILY AND SOCIAL HISTORY: The patient lives with his father and stepmother, has a pet bearded dragon, and has multiple tattoos and piercings. His stepmother has a cat, but he does not clean the litter box. The pre-transplant workup included several tests for infectious diseases, tests of organ function, radiology studies, and markers of malignancy. The only significant finding was a positive Toxoplasma gondii (T. gondii) IgM titer (> or = 1:40) (reference values for IgM: negative; < 1:40, positive; > or = 1:40) and IgG (1:2048) (reference values for IgG: negative; < 1:16, equivocal; > or = 1:16 - < 1:256, positive; > or = 1:256). Testing was done by indirect immunofluorescence assay (IFA) in April 2012 in our hospital laboratory. The patient was treated with sulfadiazine, leucovorin, and pyrimethamine. Three months later (July), he returned for follow-up testing. Real-time polymerase chain reaction (PCR) for T. gondii DNA performed by a reference laboratory was negative. One month later (August), Toxoplasma serology was performed by enzyme-linked immunosorbent assay (ELISA) by a different reference laboratory and showed an elevated IgM of 0.95 IU/mL (reference values: negative; < 0.55 IU/mL, equivocal; > or = 0.55- < 0.65 IU/mL, positive; > or = 0.65 IU/mL) and a normal level of IgG (< 4 IU/mL). At this time, PCR was repeated and was negative. An additional month later (September), the patient's serology studies were performed at a third reference laboratory and showed an elevated IgM of 1.32 IU/mL (reference values: negative; 0.89, equivocal; 0.90 - 1.09, positive; > 1.10) and a normal IgG.

  16. Plasma chemistry in peregrine falcons (Falco peregrinus): Reference values and physiological variations of importance for interpretation.

    PubMed

    Lumeij, J T; Remple, J D; Remple, C J; Riddle, K E

    1998-01-01

    Reference values (inner limits of the percentiles P(2.5) and P(97.5) are given with a probability of 95%) for 21 plasma chemical variables were established in 79 peregrine falcons (Falco peregrinus). The following values were established: urea 0.8 to 3.9 mmol/l, creatinine 24 to 64 mumol/l, glucose 16.5 to 22.0 mmol/l, sodium 150 to 170 mmol/l, chloride 114 to 131 mmol/I, inorganic phosphorus 0.55 to 1.53 mmol/l, osmolal-ity 322 to 356 mOsmol/kg, alkaline phosphatase 31 to 121 IU/l, alanine aminotransferase 29 to 90 IU/l, aspartate aminotransferase 34 to 116 U/l, gamma glutamyl transferase 0 to 3 IU/l, lactate dehydrogenase 1008 to 2650 IU/l, creatine kinase 120 to 442 IU/l, cholinesterase 143 to 325 IU/1, glutamate dehydrogenase < 8 IU/l, total bile acids 5 to 69 mumol/l, uric acid 253 to 995 mumol/l, total protein 24 to 39 g/l, albumin 12.7 to 22.4 g/l. Reference values for the calculated albumin/globulin (A/G) ratio were 0.8 to 24. Based on previous studies, reference values for calcium were established using an adjustment formula using plasma total protein concentrations (before correction 1.86 to 2.49, after correction 1.97 to 2.46 mmol/l). Results of plasma potassium concentrations were erratic which was shown to be due to a time lag between sample collection and separation of plasma and cells.

  17. Comparison of high-pressure liquid chromatography and microbiological assay for determination of ciprofloxacin tablets in human plasma employed in bioequivalence and pharmacokinetics study.

    PubMed

    Khan, Muhammad Khalid; Khan, Muhammad Farid; Mustafa, Ghulam; Sualah, Mohammed

    2012-01-01

    Ciprofloxacin was given orally to 28 healthy male volunteers for single oral dose of 500mg; Plasma samples were collected at different time's interval between 0 and 12h and analyzed both by high pressure liquid chromatography and by a microbiological assay. The detection limits (LOD) were 0.02μg/ml and 0.1μg/ml, for both methods respectively. For each method, coefficients of variation (R(2)) were 0.9995 and 0.9918 in plasma and limit of quantitation (LOQ).02 and 0.5μg/ml. The Comparison of means maximum concentration 2.68 μg/ml at 1.5 hr for test and 2.43 μg/ml are attain in HPLC method of Reference at 2hrs respectively. The plasma concentrations measured by microbiological assay of reference tablet are 3.95μg/ml (mean ± SE) at 1 hour and 3.80μg/ml (mean ± SE) at 1 hour. The concentrations in plasma measured by microbiological method were markedly higher than the high-pressure liquid chromatography values which indicates the presence of antimicrobially active metabolites. The mean ± SE values of pharmacokinetic parameters calculated by HPLC method, for total area under the curve (AUC 0-oo) were 13.11, and 11.91 h.mg/l for both test and reference tablets respectively. The mean ± SE values of clearance measured in l/h were 44.91 and 48.42 respectively. The elimination rate constant Kel [l/h] showed 0.17 l/h for test and 0.15 l/h reference tablets and likewise, absorption half-life expressed in hours shown 0.67 h for test and 1.04 h for reference respectively. The Mean Residence Time for test is 5.48 h and 5.49 h for reference. The mean ± SE values of pharmacokinetic parameters (Microbiological assay) for total area under the curve (AUC 0-oo) were 22.11 and 19.33 h.mg/l for both test and reference tablets respectively. The mean ± SE values of clearance measured in l/h were 29.02 and 31.63 respectively. The elimination rate constant Kel [l/h] showed 0.21 l/h for test and 0.20 l/h reference tablets and likewise, absorption half-life expressed in hours shown 0.86h for test and 0.56 h for reference respectively. The Mean Residence Time for test is 5.27 h and 4.67 h for reference. Significant difference observed between two methods.

  18. Evaluating the accuracy and large inaccuracy of two continuous glucose monitoring systems.

    PubMed

    Leelarathna, Lalantha; Nodale, Marianna; Allen, Janet M; Elleri, Daniela; Kumareswaran, Kavita; Haidar, Ahmad; Caldwell, Karen; Wilinska, Malgorzata E; Acerini, Carlo L; Evans, Mark L; Murphy, Helen R; Dunger, David B; Hovorka, Roman

    2013-02-01

    This study evaluated the accuracy and large inaccuracy of the Freestyle Navigator (FSN) (Abbott Diabetes Care, Alameda, CA) and Dexcom SEVEN PLUS (DSP) (Dexcom, Inc., San Diego, CA) continuous glucose monitoring (CGM) systems during closed-loop studies. Paired CGM and plasma glucose values (7,182 data pairs) were collected, every 15-60 min, from 32 adults (36.2±9.3 years) and 20 adolescents (15.3±1.5 years) with type 1 diabetes who participated in closed-loop studies. Levels 1, 2, and 3 of large sensor error with increasing severity were defined according to absolute relative deviation greater than or equal to ±40%, ±50%, and ±60% at a reference glucose level of ≥6 mmol/L or absolute deviation greater than or equal to ±2.4 mmol/L,±3.0 mmol/L, and ±3.6 mmol/L at a reference glucose level of <6 mmol/L. Median absolute relative deviation was 9.9% for FSN and 12.6% for DSP. Proportions of data points in Zones A and B of Clarke error grid analysis were similar (96.4% for FSN vs. 97.8% for DSP). Large sensor over-reading, which increases risk of insulin over-delivery and hypoglycemia, occurred two- to threefold more frequently with DSP than FSN (once every 2.5, 4.6, and 10.7 days of FSN use vs. 1.2, 2.0, and 3.7 days of DSP use for Level 1-3 errors, respectively). At levels 2 and 3, large sensor errors lasting 1 h or longer were absent with FSN but persisted with DSP. FSN and DSP differ substantially in the frequency and duration of large inaccuracy despite only modest differences in conventional measures of numerical and clinical accuracy. Further evaluations are required to confirm that FSN is more suitable for integration into closed-loop delivery systems.

  19. Pediatric Reference Intervals for Free Thyroxine and Free Triiodothyronine

    PubMed Central

    Jang, Megan; Guo, Tiedong; Soldin, Steven J.

    2009-01-01

    Background The clinical value of free thyroxine (FT4) and free triiodothyronine (FT3) analysis depends on the reference intervals with which they are compared. We determined age- and sex-specific reference intervals for neonates, infants, and children 0–18 years of age for FT4 and FT3 using tandem mass spectrometry. Methods Reference intervals were calculated for serum FT4 (n = 1426) and FT3 (n = 1107) obtained from healthy children between January 1, 2008, and June 30, 2008, from Children's National Medical Center and Georgetown University Medical Center Bioanalytical Core Laboratory, Washington, DC. Serum samples were analyzed using isotope dilution liquid chromatography tandem mass spectrometry (LC/MS/MS) with deuterium-labeled internal standards. Results FT4 reference intervals were very similar for males and females of all ages and ranged between 1.3 and 2.4 ng/dL for children 1 to 18 years old. FT4 reference intervals for 1- to 12-month-old infants were 1.3–2.8 ng/dL. These 2.5 to 97.5 percentile intervals were much tighter than reference intervals obtained using immunoassay platforms 0.48–2.78 ng/dL for males and 0.85–2.09 ng/dL for females. Similarly, FT3 intervals were consistent and similar for males and females and for all ages, ranging between 1.5 pg/mL and approximately 6.0 pg/mL for children 1 month of age to 18 years old. Conclusions This is the first study to provide pediatric reference intervals of FT4 and FT3 for children from birth to 18 years of age using LC/MS/MS. Analysis using LC/MS/MS provides more specific quantification of thyroid hormones. A comparison of the ultrafiltration tandem mass spectrometric method with equilibrium dialysis showed very good correlation. PMID:19583487

  20. Cord blood calcium, phosphate, magnesium, and alkaline phosphatase gestational age-specific reference intervals for preterm infants.

    PubMed

    Fenton, Tanis R; Lyon, Andrew W; Rose, M Sarah

    2011-08-31

    The objective was to determine the influence of gestational age, maternal, and neonatal variables on reference intervals for cord blood bone minerals (calcium, phosphate, magnesium) and related laboratory tests (alkaline phosphatase, and albumin-adjusted calcium), and to develop gestational age specific reference intervals based on infants without influential pathological conditions. Cross-sectional study. 702 babies were identified as candidates for this study in a regional referral neonatal unit. After exclusions (for anomalies, asphyxia, maternal magnesium sulfate administration, and death), relationships were examined between cord blood serum laboratory analytes (calcium, phosphate, magnesium, alkaline phosphatase, and albumin-adjusted calcium) with gestation age and also with maternal and neonatal variables using multiple linear regression. Infants with influential pathological conditions were omitted from the development of gestational age specific reference intervals for the following categories: 23-27, 28-31, 32-34, 35-36 and > 36 weeks. Among the 506 preterm and 54 terms infants included in the sample. Phosphate, magnesium, and alkaline phosphatase in cord blood serum decreased with gestational age, calcium increased with gestational age. Those who were triplets, small for gestational age, and those whose mother had pregnancy-induced hypertension were influential for most of the analytes. The reference ranges for the preterm infants ≥ 36 weeks were: phosphate 1.5 to 2.6 mmol/L (4.5 to 8.0 mg/dL), calcium: 2.1 to 3.1 mmol/L (8.3 to 12.4 mg/dL); albumin-adjusted calcium: 2.3 to 3.2 mmol/L (9.1 to 12.9 mg/dL); magnesium 0.6 to 1.0 mmol/L (1.4 to 2.3 mg/dL), and alkaline phosphatase 60 to 301 units/L. These data suggest that gestational age, as well as potentially pathogenic maternal and neonatal variables should be considered in the development of reference intervals for preterm infants.

  1. Conceptual Design of a Synoptic Interplanetary Monitor Platform at L sub 1 (SIMPL).

    DTIC Science & Technology

    1985-11-01

    solar events. -159- . . . .. . 105 II1II" -I .5 year mission at Earth-Sun- libration point plus transfer orbit eDashed line is approximate true dose as...Design .. ...................................... 27 4.1 The L Libration Point .......................... 27 4.2 L Orbit Options...34) to provide power, attitude control, communications, and other support to maintain the instruments in a halo orbit around the L libration point ; 4. a

  2. Point-of-care C-reactive protein-based tuberculosis screening for people living with HIV: a diagnostic accuracy study.

    PubMed

    Yoon, Christina; Semitala, Fred C; Atuhumuza, Elly; Katende, Jane; Mwebe, Sandra; Asege, Lucy; Armstrong, Derek T; Andama, Alfred O; Dowdy, David W; Davis, J Luke; Huang, Laurence; Kamya, Moses; Cattamanchi, Adithya

    2017-12-01

    Symptom-based screening for tuberculosis is recommended for all people living with HIV. This recommendation results in unnecessary Xpert MTB/RIF testing in many individuals living in tuberculosis-endemic areas and thus poor implementation of intensified case finding and tuberculosis preventive therapy. Novel approaches to tuberculosis screening are needed to help achieve global targets for tuberculosis elimination. We assessed the performance of C-reactive protein (CRP) measured with a point-of-care assay as a screening tool for active pulmonary tuberculosis. For this prospective study, we enrolled adults (aged ≥18 years) living with HIV with CD4 cell count less than or equal to 350 cells per μL who were initiating antiretroviral therapy (ART) from two HIV/AIDS clinics in Uganda. CRP concentrations were measured at study entry with a point-of-care assay using whole blood obtained by fingerprick (concentration ≥10 mg/L defined as screen positive for tuberculosis). Sputum samples were collected for Xpert MTB/RIF testing and culture. We calculated the sensitivity and specificity of point-of-care CRP and WHO symptom-based screening in reference to culture results. We repeated the sensitivity analysis with Xpert MTB/RIF as the reference standard. Between July 8, 2013, and Dec 15, 2015, 1237 HIV-infected adults were enrolled and underwent point-of-care CRP testing. 60 (5%) patients with incomplete or contaminated cultures were excluded from the analysis. Of the remaining 1177 patients (median CD4 count 165 cells per μL [IQR 75-271]), 163 (14%) had culture-confirmed tuberculosis. Point-of-care CRP testing had 89% sensitivity (145 of 163, 95% CI 83-93) and 72% specificity (731 of 1014, 95% CI 69-75) for culture-confirmed tuberculosis. Compared with WHO symptom-based screening, point-of-care CRP testing had lower sensitivity (difference -7%, 95% CI -12 to -2; p=0·002) but substantially higher specificity (difference 58%, 95% CI 55 to 61; p<0·0001). When Xpert MTB/RIF results were used as the reference standard, sensitivity of point-of-care CRP and WHO symptom-based screening were similar (94% [79 of 84] vs 99% [83 of 84], respectively; difference -5%, 95% CI -12 to 2; p=0·10). The performance characteristics of CRP support its use as a tuberculosis screening test for people living with HIV with CD4 count less than or equal to 350 cells per μL who are initiating ART. HIV/AIDS programmes should consider point-of-care CRP-based tuberculosis screening to improve the efficiency of intensified case finding and increase uptake of tuberculosis preventive therapy. National Institutes of Health; President's Emergency Plan for AIDS Relief; University of California, San Francisco, Nina Ireland Program for Lung Health. Copyright © 2017 Elsevier Ltd. All rights reserved.

  3. Comparative Bioavailability and Tolerability of a Single 2-mg Dose of 2 Repaglinide Tablet Formulations in Fasting, Healthy Chinese Male Volunteers: An Open-Label, Randomized-Sequence, 2-Period Crossover Study☆

    PubMed Central

    Zhai, Xue-jia; Hu, Kai; Chen, Fen; Lu, Yong-ning

    2013-01-01

    Background Repaglinide, an oral insulin secretagogue, was the first meglitinide analogue to be approved for use in patients with type 2 diabetes mellitus. Objective In our study, the bioavailability and tolerability of the proposed generic formulation with the established reference formulation of repaglinide 2 mg were compared in a fasting, healthy Chinese male population. Methods This 2-week, open-label, randomized-sequence, single-dose, 2-period crossover study was conducted in 22 healthy native Han Chinese male volunteers. Eligible subjects were randomly assigned in a 1:1 ratio to receive a single 2-mg dose of the test or reference formulation, followed by a 7-day washout period and administration of the alternate formulation. After an overnight fast, subjects received a single oral dose of repaglinide (2 mg). Blood samples were drawn at predetermined time points (0, 0.25, 0.5, 0.75, 1, 1.25, 1.5, 2.0, 2.5, 3.0, 4.0, 5.0, and 6.0 hours). All plasma concentrations of repaglinide were measured by LC-MS/MS. The observed Cmax, Tmax, t1/2, and AUC were assessed. The formulations were to be considered bioequivalent if the ln-transformed ratios of Cmax and AUC were within the predetermined bioequivalence range of 80% to 125% established by the State Food and Drug Administration of the People’s Republic of China. Tolerability was assessed throughout the study via subject interview, vital signs, and blood sampling. Results The mean (SD) age of the subjects was 24.2 (2.3) years; their mean (SD) weight was 62.6 (5.8) kg, their mean (SD) height was 172 (5.7) cm, and their mean (SD) body mass index was 21.0 (1.1). The mean (SD) Cmax for repaglinide with the test and reference formulations were 20.0 (5.1) and 18.7 (8.7) ng/mL. The AUC0–t for the test formulation was 46.3 (15.1) and AUC0–∞ was 47.9 (16.5) ng•h/mL. With the reference formulation, the corresponding values were 46.4 (26.1) and 49.0 (31.3) ng•h/mL. The mean (SD) Tmax values with the test and reference formulations were 1.2 (0.7) hours and 1.5 (0.8) hours and the mean (SD) values t1/2 values were 1.0 (0.3), and 0.9 (0.3) hours, respectively. The ln-transformed ratios of Cmax, AUC0–t, and AUC0–∞ were 113.6:1, 105.6:1, and 104.7:1. The corresponding 90% CIs were 99.8 to 129.2, 93.4 to 119.5, and 91.8 to 119.5, respectively. Conclusions This single-dose study found that the test and reference formulations of repaglinide met the regulatory criteria for bioequivalence in these fasting, healthy Chinese male volunteers. Both formulations appeared to be well tolerated. ClinicalTrials.gov identifier: 2012L01684. PMID:24465043

  4. Comparative Bioavailability and Tolerability of a Single 2-mg Dose of 2 Repaglinide Tablet Formulations in Fasting, Healthy Chinese Male Volunteers: An Open-Label, Randomized-Sequence, 2-Period Crossover Study.

    PubMed

    Zhai, Xue-Jia; Hu, Kai; Chen, Fen; Lu, Yong-Ning

    2013-12-01

    Repaglinide, an oral insulin secretagogue, was the first meglitinide analogue to be approved for use in patients with type 2 diabetes mellitus. In our study, the bioavailability and tolerability of the proposed generic formulation with the established reference formulation of repaglinide 2 mg were compared in a fasting, healthy Chinese male population. This 2-week, open-label, randomized-sequence, single-dose, 2-period crossover study was conducted in 22 healthy native Han Chinese male volunteers. Eligible subjects were randomly assigned in a 1:1 ratio to receive a single 2-mg dose of the test or reference formulation, followed by a 7-day washout period and administration of the alternate formulation. After an overnight fast, subjects received a single oral dose of repaglinide (2 mg). Blood samples were drawn at predetermined time points (0, 0.25, 0.5, 0.75, 1, 1.25, 1.5, 2.0, 2.5, 3.0, 4.0, 5.0, and 6.0 hours). All plasma concentrations of repaglinide were measured by LC-MS/MS. The observed Cmax, Tmax, t1/2, and AUC were assessed. The formulations were to be considered bioequivalent if the ln-transformed ratios of Cmax and AUC were within the predetermined bioequivalence range of 80% to 125% established by the State Food and Drug Administration of the People's Republic of China. Tolerability was assessed throughout the study via subject interview, vital signs, and blood sampling. The mean (SD) age of the subjects was 24.2 (2.3) years; their mean (SD) weight was 62.6 (5.8) kg, their mean (SD) height was 172 (5.7) cm, and their mean (SD) body mass index was 21.0 (1.1). The mean (SD) Cmax for repaglinide with the test and reference formulations were 20.0 (5.1) and 18.7 (8.7) ng/mL. The AUC0-t for the test formulation was 46.3 (15.1) and AUC0-∞ was 47.9 (16.5) ng(•)h/mL. With the reference formulation, the corresponding values were 46.4 (26.1) and 49.0 (31.3) ng(•)h/mL. The mean (SD) Tmax values with the test and reference formulations were 1.2 (0.7) hours and 1.5 (0.8) hours and the mean (SD) values t1/2 values were 1.0 (0.3), and 0.9 (0.3) hours, respectively. The ln-transformed ratios of Cmax, AUC0-t, and AUC0-∞ were 113.6:1, 105.6:1, and 104.7:1. The corresponding 90% CIs were 99.8 to 129.2, 93.4 to 119.5, and 91.8 to 119.5, respectively. This single-dose study found that the test and reference formulations of repaglinide met the regulatory criteria for bioequivalence in these fasting, healthy Chinese male volunteers. Both formulations appeared to be well tolerated. ClinicalTrials.gov identifier: 2012L01684.

  5. Exploratory study of serum ubiquitin carboxyl-terminal esterase L1 and glial fibrillary acidic protein for outcome prognostication after pediatric cardiac arrest.

    PubMed

    Fink, Ericka L; Berger, Rachel P; Clark, Robert S B; Watson, R Scott; Angus, Derek C; Panigrahy, Ashok; Richichi, Rudolph; Callaway, Clifton W; Bell, Michael J; Mondello, Stefania; Hayes, Ronald L; Kochanek, Patrick M

    2016-04-01

    Brain injury is the leading cause of morbidity and death following pediatric cardiac arrest. Serum biomarkers of brain injury may assist in outcome prognostication. The objectives of this study were to evaluate the properties of serum ubiquitin carboxyl-terminal esterase-L1 (UCH-L1) and glial fibrillary acidic protein (GFAP) to classify outcome in pediatric cardiac arrest. Single center prospective study. Serum biomarkers were measured at 2 time points during the initial 72 h in children after cardiac arrest (n=19) and once in healthy children (controls, n=43). We recorded demographics and details of the cardiac arrest and resuscitation. We determined the associations between serum biomarker concentrations and Pediatric Cerebral Performance Category (PCPC) at 6 months (favorable (PCPC 1-3) or unfavorable (PCPC 4-6)). The initial assessment (time point 1) occurred at a median (IQR) of 10.5 (5.5-17.0)h and the second assessment (time point 2) at 59.0 (54.5-65.0)h post-cardiac arrest. Serum UCH-L1 was higher among children following cardiac arrest than among controls at both time points (p<0.05). Serum GFAP in subjects with unfavorable outcome was higher at time point 2 than in controls (p<0.05). Serum UCH-L1 at time point 1 (AUC 0.782) and both UCH-L1 and GFAP at time point 2 had good classification accuracy for outcome (AUC 0.822 and 0.796), p<0.05 for all. Preliminary data suggest that serum UCH-L1 and GFAP may be of use to prognosticate outcome after pediatric cardiac arrest at clinically-relevant time points and should be validated prospectively. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  6. Exploratory Study of Serum Ubiquitin Carboxyl-Terminal Esterase L1 and Glial Fibrillary Acidic Protein for Outcome Prognostication after Pediatric Cardiac Arrest

    PubMed Central

    Fink, Ericka L; Berger, Rachel P; Clark, Robert SB; Watson, R. Scott; Angus, Derek C; Panigrahy, Ashok; Richichi, Rudolph; Callaway, Clifton W; Bell, Michael J; Mondello, Stefania; Hayes, Ronald L.; Kochanek, Patrick M

    2016-01-01

    Introduction Brain injury is the leading cause of morbidity and death following pediatric cardiac arrest. Serum biomarkers of brain injury may assist in outcome prognostication. The objectives of this study were to evaluate the properties of serum ubiquitin carboxyl-terminal esterase-L1 (UCH-L1) and glial fibrillary acidic protein (GFAP) to classify outcome in pediatric cardiac arrest. Methods Single center prospective study. Serum biomarkers were measured at 2 time points during the initial 72 h in children after cardiac arrest (n=19) and once in healthy children (controls, n=43). We recorded demographics and details of the cardiac arrest and resuscitation. We determined the associations between serum biomarker concentrations and Pediatric Cerebral Performance Category (PCPC) at 6 months (favorable (PCPC 1–3) or unfavorable (PCPC 4–6)). Results The initial assessment (time point 1) occurred at a median (IQR) of 10.5 (5.5–17.0) h and the second assessment (time point 2) at 59.0 (54.5–65.0) h post-cardiac arrest. Serum UCH-L1 was higher among children following cardiac arrest than among controls at both time points (p<0.05). Serum GFAP in subjects with unfavorable outcome was higher at time point 2 than in controls (p<0.05). Serum UCH-L1 at time point 1 (AUC 0.782) and both UCH-L1 and GFAP at time point 2 had good classification accuracy for outcome (AUC 0.822 and 0.796), p<0.05 for all. Conclusion Preliminary data suggest that serum UCH-L1 and GFAP may be of use to prognosticate outcome after pediatric cardiac arrest at clinically-relevant time points and should be validated prospectively. PMID:26855294

  7. 46 CFR 45.127 - Position of structures, openings, and fittings.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... quarter deck; (2) A superstructure deck or a trunk deck and forward of a point 1/4 L from the forward... deck aft of a point 1/4 L abaft the forward perpendicular; or (2) On a superstructure and trunk combination, that is H s or more n height, aft or a point 1/4 L abaft the forward perpendicular. ...

  8. 46 CFR 45.127 - Position of structures, openings, and fittings.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... quarter deck; (2) A superstructure deck or a trunk deck and forward of a point 1/4 L from the forward... deck aft of a point 1/4 L abaft the forward perpendicular; or (2) On a superstructure and trunk combination, that is H s or more n height, aft or a point 1/4 L abaft the forward perpendicular. ...

  9. Compound heterozygous mutation of aquaporin 2 gene in woman patient with congenital nephrogenic diabetes insipidus.

    PubMed

    Tsutsumi, Zenta; Inokuchi, Taku; Tamada, Daisuke; Moriwaki, Yuji; Ka, Tsuneyoshi; Takahashi, Sumio; Yamamoto, Tetsuya

    2009-01-01

    We performed mutational analyses of a woman patient with congenital nephrogenic diabetes insipidus referred to us during pregnancy. The diagnosis was made during the neonatal period, after which she was treated with spironolactone and hydrochlorothiazide. Our examination showed the patient to be apparently in good health without definite evidence of dehydration. Serum and urine osmolality were 220 mOsm/L and 50 mOsm/L, respectively, and the serum concentration of AVP was 2.7 pg/mL. Results of a water-deprivation test performed after delivery were compatible with nephrogenic diabetes insipidus. Mutational analyses showed that the patient was a compound heterozygote with point mutations at nucleotide position 298 (G to A; G100R) in exon 1 and nucleotide position 374 (C to T; T125M) in exon 2 of the aquaporin 2 gene, which have been previously described.

  10. The bioavailability of manganese in welders in relation to its solubility in welding fumes.

    PubMed

    Ellingsen, Dag G; Zibarev, Evgenij; Kusraeva, Zarina; Berlinger, Balazs; Chashchin, Maxim; Bast-Pettersen, Rita; Chashchin, Valery; Thomassen, Yngvar

    2013-02-01

    Blood and urine samples for determination of manganese (Mn) and iron (Fe) concentrations were collected in a cross-sectional study of 137 currently exposed welders, 137 referents and 34 former welders. Aerosol samples for measurements of personal air exposure to Mn and Fe were also collected. The aerosol samples were assessed for their solubility using a simulated lung lining fluid (Hatch solution). On average 13.8% of the total Mn mass (range 1-49%; N = 237) was soluble (Hatch sol), while only 1.4% (<0.1-10.0%; N = 237) of the total Fe mass was Hatch sol. The welders had statistically significantly higher geometric mean concentrations of Mn in whole blood (B-Mn 12.8 vs. 8.0 μg L (-1)), serum (S-Mn 1.04 vs. 0.77 μg L(-1)) and urine (U-Mn 0.36 vs. 0.07 μg g (-1) cr.) than the referents. Statistically significant univariate correlations were observed between exposure to Hatch sol Mn in the welding aerosol and B-Mn, S-Mn and U-Mn respectively. Pearson's correlation coefficient between mean Hatch sol Mn of two days preceding the collection of biological samples and U-Mn was 0.46 (p < 0.001). The duration of employment as a welder in years was also associated with B-Mn and S-Mn, but not with U-Mn. Statistically significantly higher U-Mn and B-Mn were observed in welders currently exposed to even less than 12 and 6 μg m (-3) Hatchsol Mn, respectively. When using the 95(th) percentile concentration among the referents as a cut-point, 70.0 and 64.5% of the most highly exposed welders exceeded this level with respect to B-Mn and U-Mn. The concentrations of B-Mn, S-Mn and U-Mn were all highly correlated in the welders, but not in the referents.

  11. Effect of Receiver Choosing on Point Positions Determination in Network RTK

    NASA Astrophysics Data System (ADS)

    Bulbul, Sercan; Inal, Cevat

    2016-04-01

    Nowadays, the developments in GNSS technique allow to determinate point positioning in real time. Initially, point positioning was determined by RTK (Real Time Kinematic) based on a reference station. But, to avoid systematic errors in this method, distance between the reference points and rover receiver must be shorter than10 km. To overcome this restriction in RTK method, the idea of setting more than one reference point had been suggested and, CORS (Continuously Operations Reference Systems) was put into practice. Today, countries like ABD, Germany, Japan etc. have set CORS network. CORS-TR network which has 146 reference points has also been established in 2009 in Turkey. In CORS-TR network, active CORS approach was adopted. In Turkey, CORS-TR reference stations covering whole country are interconnected and, the positions of these stations and atmospheric corrections are continuously calculated. In this study, in a selected point, RTK measurements based on CORS-TR, were made with different receivers (JAVAD TRIUMPH-1, TOPCON Hiper V, MAGELLAN PRoMark 500, PENTAX SMT888-3G, SATLAB SL-600) and with different correction techniques (VRS, FKP, MAC). In the measurements, epoch interval was taken as 5 seconds and measurement time as 1 hour. According to each receiver and each correction technique, means and differences between maximum and minimum values of measured coordinates, root mean squares in the directions of coordinate axis and 2D and 3D positioning precisions were calculated, the results were evaluated by statistical methods and the obtained graphics were interpreted. After evaluation of the measurements and calculations, for each receiver and each correction technique; the coordinate differences between maximum and minimum values were measured to be less than 8 cm, root mean squares in coordinate axis directions less than ±1.5 cm, 2D point positioning precisions less than ±1.5 cm and 3D point positioning precisions less than ±1.5 cm. In the measurement point, it has been concluded that VRS correction technique is generally better than other corrections techniques.

  12. Biological thresholds of nitrogen and phosphorus in a typical urban river system of the Yangtz delta, China.

    PubMed

    Liang, Xinqiang; Zhu, Sirui; Ye, Rongzhong; Guo, Ru; Zhu, Chunyan; Fu, Chaodong; Tian, Guangming; Chen, Yingxu

    2014-09-01

    River health and associated risks are fundamentally dependent on the levels of the primary productivities, i.e., sestonic and benthic chlorophyll-a. We selected a typical urban river system of the Yangtz delta to investigate nutrient and non-nutrient responses of chlorophyll-a contents and to determine biological thresholds of N and P. Results showed the mean contents of sestonic and benthic chlorophyll-a across all sampling points reached 10.2 μg L(-1) and 149.3 mg m(-2). The self-organized mapping analysis suggested both chlorophyll-a contents clearly responded to measurements of N, P, and water temperature. Based on the chlorophyll-a criteria for fresh water and measured variables, we recommend the biological thresholds of N and P for our river system be set at 2.4 mg N L(-1) and 0.2 mg P L(-1), and these be used as initial nutrient reference values for local river managers to implement appropriate strategies to alleviate nutrient loads and trophic status. Copyright © 2014 Elsevier Ltd. All rights reserved.

  13. Early thyroxine treatment in Down syndrome and thyroid function later in life.

    PubMed

    Zwaveling-Soonawala, Nitash; Witteveen, M Emma; Marchal, Jan Pieter; Klouwer, Femke C C; Ikelaar, Nadine A; Smets, Anne M J B; van Rijn, Rick R; Endert, Erik; Fliers, Eric; van Trotsenburg, A S Paul

    2017-05-01

    The hypothalamus-pituitary-thyroid (HPT) axis set point develops during the fetal period and first two years of life. We hypothesized that thyroxine treatment during these first two years, in the context of a randomized controlled trial (RCT) in children with Down syndrome, may have influenced the HPT axis set point and may also have influenced the development of Down syndrome-associated autoimmune thyroiditis. We included 123 children with Down syndrome 8.7 years after the end of an RCT comparing thyroxine treatment vs placebo and performed thyroid function tests and thyroid ultrasound. We analyzed TSH and FT4 concentrations in the subgroup of 71 children who were currently not on thyroid medication and had no evidence of autoimmune thyroiditis. TSH concentrations did not differ, but FT4 was significantly higher in the thyroxine-treated group than that in the placebo group (14.1 vs 13.0 pmol/L; P  = 0.02). There was an increase in anti-TPO positivity, from 1% at age 12 months to 6% at age 24 months and 25% at age 10.7 years with a greater percentage of children with anti-TPO positivity in the placebo group (32%) compared with the thyroxine-treated group (18.5%) ( P  = 0.12). Thyroid volume at age 10.7 years (mean: 3.4 mL; range: 0.5-7.5 mL) was significantly lower ( P  < 0.01) compared with reference values (5.5 mL; range: 3-9 mL) and was similar in the thyroxine and placebo group. Thyroxine treatment during the first two years of life led to a mild increase in FT4 almost 9 years later on and may point to an interesting new mechanism influencing the maturing HPT axis set point. Furthermore, there was a trend toward less development of thyroid autoimmunity in the thyroxine treatment group, suggesting a protective effect of the early thyroxine treatment. Lastly, thyroid volume was low possibly reflecting Down-specific thyroid hypoplasia. © 2017 European Society of Endocrinology.

  14. Use of capillary blood glucose for screening for gestational diabetes mellitus in resource-constrained settings.

    PubMed

    Bhavadharini, Balaji; Mahalakshmi, Manni Mohanraj; Maheswari, Kumar; Kalaiyarasi, Gunasekaran; Anjana, Ranjit Mohan; Deepa, Mohan; Ranjani, Harish; Priya, Miranda; Uma, Ram; Usha, Sriram; Pastakia, Sonak D; Malanda, Belma; Belton, Anne; Unnikrishnan, Ranjit; Kayal, Arivudainambi; Mohan, Viswanathan

    2016-02-01

    The aim of the study was to evaluate usefulness of capillary blood glucose (CBG) for diagnosis of gestational diabetes mellitus (GDM) in resource-constrained settings where venous plasma glucose (VPG) estimations may be impossible. Consecutive pregnant women (n = 1031) attending antenatal clinics in southern India underwent 75-g oral glucose tolerance test (OGTT). Fasting, 1- and 2-h VPG (AU2700 Beckman, Fullerton, CA) and CBG (One Touch Ultra-II, LifeScan) were simultaneously measured. Sensitivity and specificity were estimated for different CBG cut points using the International Association of Diabetes in Pregnancy Study Groups (IADPSG) criteria for the diagnosis of GDM as gold standard. Bland-Altman plots were drawn to look at the agreement between CBG and VPG. Correlation and regression equation analysis were also derived for CBG values. Pearson's correlation between VPG and CBG for fasting was r = 0.433 [intraclass correlation coefficient (ICC) = 0.596, p < 0.001], for 1H, it was r = 0.653 (ICC = 0.776, p < 0.001), and for 2H, r = 0.784 (ICC = 0.834, p < 0.001). Comparing a single CBG 2-h cut point of 140 mg/dl (7.8 mmol/l) with the IADPSG criteria, the sensitivity and specificity were 62.3 and 80.7 %, respectively. If CBG cut points of 120 mg/dl (6.6 mmol/l) or 110 mg/dl (6.1 mmol/l) were used, the sensitivity improves to 78.3 and 92.5 %, respectively. In settings where VPG estimations are not possible, CBG can be used as an initial screening test for GDM, using lower 2H CBG cut points to maximize the sensitivity. Those who screen positive can be referred to higher centers for definitive testing, using VPG.

  15. Determination of Cd in urine by cloud point extraction-tungsten coil atomic absorption spectrometry.

    PubMed

    Donati, George L; Pharr, Kathryn E; Calloway, Clifton P; Nóbrega, Joaquim A; Jones, Bradley T

    2008-09-15

    Cadmium concentrations in human urine are typically at or below the 1 microgL(-1) level, so only a handful of techniques may be appropriate for this application. These include sophisticated methods such as graphite furnace atomic absorption spectrometry and inductively coupled plasma mass spectrometry. While tungsten coil atomic absorption spectrometry is a simpler and less expensive technique, its practical detection limits often prohibit the detection of Cd in normal urine samples. In addition, the nature of the urine matrix often necessitates accurate background correction techniques, which would add expense and complexity to the tungsten coil instrument. This manuscript describes a cloud point extraction method that reduces matrix interference while preconcentrating Cd by a factor of 15. Ammonium pyrrolidinedithiocarbamate and Triton X-114 are used as complexing agent and surfactant, respectively, in the extraction procedure. Triton X-114 forms an extractant coacervate surfactant-rich phase that is denser than water, so the aqueous supernatant is easily removed leaving the metal-containing surfactant layer intact. A 25 microL aliquot of this preconcentrated sample is placed directly onto the tungsten coil for analysis. The cloud point extraction procedure allows for simple background correction based either on the measurement of absorption at a nearby wavelength, or measurement of absorption at a time in the atomization step immediately prior to the onset of the Cd signal. Seven human urine samples are analyzed by this technique and the results are compared to those found by the inductively coupled plasma mass spectrometry analysis of the same samples performed at a different institution. The limit of detection for Cd in urine is 5 ngL(-1) for cloud point extraction tungsten coil atomic absorption spectrometry. The accuracy of the method is determined with a standard reference material (toxic metals in freeze-dried urine) and the determined values agree with the reported levels at the 95% confidence level.

  16. Water Quality Assessment and Determining the Carrying Capacity of Pollution Load Batang Kuranji River

    NASA Astrophysics Data System (ADS)

    Dewata, I.; Adri, Z.

    2018-04-01

    This study aims to determine the water quality and carrying capacity of pollution load Batang Kuranji River in the headwaters, middle, and downstream. This research is descriptive quantitative parameters of pH, BOD, COD, TSS, and DOES Depictions of river water quality refer to RegulationNo.82/2001, while determination of carrying capacity of pollution load river refers to the Kep Men LHNo.10/2003.The result is Kuranji Batang River water quality upstream region included in either category who meet the quality standard first class ofPP82/2001. TSS concentrations at head waters of 21 mg/L, BOD1,6 mg/L, COD7,99mg/L and DO 7,845 mg/L. While the carrying capacity of pollution load river in upstream region included in both categories namely BOD of 4,4 kg/sec, COD 273,60 kg/sec, TSS906,00kg/sec, and DO parameters of 49.20 kg/sec. Middle region (point 2, 3, and 4) water quality Batang Kuranji River has exceeded the quality standard of 82/2001 for class II and class III. Meanwhile, carrying capacity of pollution load river in area included in ugly category. The calculation is done with application Qual2Kw show that carrying capacity of pollution load river of BOD -857.3 kg/sec, COD -777.40 kg/sec, TSS +9511.5 kg/sec, and DO +69.30 kg/sec.

  17. Distributed Arrays and Signal Processing for the TechSat21 Space-Based Radar

    DTIC Science & Technology

    2009-04-01

    lIlustrating the derivation of minimum aperture size and coherent integration time ............. 25 B 4. Global coordinate system and satellite-based...work of Dr. Robert Mailloux. Dr. Peter Franchi . and Dr. Scott Santarelli. VII Summary The TechSat2l space-based radar concept, suggested by AFRUVS...Linearization for small motions around a reference point in a global circular orbit leads to the Hill equations, derived in 1878, and alternatively named

  18. [Personalizing the reference level: gold standard to evaluate the quality of service perceived].

    PubMed

    Rodrigo-Rincón, I; Reyes-Pérez, M; Martínez-Lozano, M E

    2014-01-01

    To know the cutoff point at which in-house Nuclear Medicine Department (MND) customers consider that the quality of service is good (personalized cutoff). We conducted a survey of the professionals who had requested at least 5 tests to the Nuclear Medicine Department. A total of 71 doctors responded (response rate: 30%). A question was added to the questionnaire for the user to establish a cutoff point for which they would consider the quality of service as good. The quality non-conformities, areas of improvement and strong points of the six questions measuring the quality of service (Likert scale 0 to 10) were compared with two different thresholds: personalized cutoff and one proposed by the service itself a priori. Test statistics: binomial and Student's t-test for paired data. A cutoff value of 7 was proposed by the service as a reference while 68.1% of respondents suggested a cutoff above 7 points (mean 7.9 points). The 6 elements of perceived quality were considered strong points with the cutoff proposed by the MND, while there were 3 detected with the personalized threshold. Thirteen percent of the answers were nonconformities with the service cutoff versus 19.2% with the personalized one, the differences being statistically significant (difference 95% CI 6.44%:0,83-12.06). The final image of the perceived quality of an in-house customer is different when using the cutoff established by the Department versus the personalized cutoff given by the respondent. Copyright © 2013 Elsevier España, S.L. and SEMNIM. All rights reserved.

  19. Preliminary Design Considerations for Access and Operations in Earth-Moon L1/L2 Orbits

    NASA Technical Reports Server (NTRS)

    Folta, David C.; Pavlak, Thomas A.; Haapala, Amanda F.; Howell, Kathleen C.

    2013-01-01

    Within the context of manned spaceflight activities, Earth-Moon libration point orbits could support lunar surface operations and serve as staging areas for future missions to near-Earth asteroids and Mars. This investigation examines preliminary design considerations including Earth-Moon L1/L2 libration point orbit selection, transfers, and stationkeeping costs associated with maintaining a spacecraft in the vicinity of L1 or L2 for a specified duration. Existing tools in multi-body trajectory design, dynamical systems theory, and orbit maintenance are leveraged in this analysis to explore end-to-end concepts for manned missions to Earth-Moon libration points.

  20. Abnormal glomerular filtration rate in children, adolescents and young adults starts below 75 mL/min/1.73 m(2).

    PubMed

    Pottel, Hans; Hoste, Liesbeth; Delanaye, Pierre

    2015-05-01

    The chronic kidney disease (CKD) classification system for children is similar to that for adults, with both mainly based on estimated glomerular filtration rate (eGFR) combined with fixed cut-off values. The main cut-off eGFR value used to define CKD is 60 mL/min/1.73 m(2), a value that is also applied for children older than 2 years of age, adolescents and young adults. Based on a literature search, we evaluated inclusion criteria for eGFR in clinical trials or research studies on CKD for children. We also collected information on direct measurements of GFR (mGFR) in children and adolescents, with the aim to estimate the normal reference range for GFR. Using serum creatinine (Scr) normal reference values and Scr-based eGFR-equations, we also evaluated the correspondence between Scr normal reference values and (e)GFR normal reference values. Based on our literature search, the inclusion of children in published CKD studies has been based on cut-off values for eGFR of >60 mL/min/1.73 m(2). The lower reference limits for mGFR far exceed this adult threshold. Using eGFR values calculated using Scr-based formulas, we found that abnormal Scr levels in children already correspond to eGFR values that are below a cut-off of 75 mL/min/1.73 m(2). Abnormal GFR in children, adolescents and young adults starts below 75 mL/min/1.73 m(2), and as abnormality is a sign of disease, we recommend referring children, adolescents and young adults with an (e)GFR of <75 mL/min/1.73 m(2) for further clinical assessment.

  1. Rest-wavelength Fiducials for the ITER Core Imaging X-ray Spectrometer

    NASA Technical Reports Server (NTRS)

    Beiersdorfer, P.; Brown, G. V.; Graf, A. T.; Bitter, M.; Hill, K. W.; Kelley, R. L.; Kilbourne, C. A.; Leutenegger, M. A.; Porter, F. S.

    2012-01-01

    Absolute wavelength references are needed to derive the plasma velocities from the Doppler shift of a given line emitted by a moving plasma. We show that such reference standards exist for the strongest x-ray line in neonlike W64+, which has become the line of choice for the ITER (Latin the way) core imaging x-ray spectrometer. Close-by standards are the Hf L3 line and the Ir L2 line, which bracket the W64+ line by 30 eV; other standards are given by the Ir L1 and L2 lines and the Hf L1 and L2 lines, which bracket the W64+ line by 40 and 160 eV, respectively. The reference standards can be produced by an x-ray tube built into the ITER spectrometer. We present spectra of the reference lines obtained with an x-ray microcalorimeter and compare them to spectra of the W64+ line obtained both with an x-ray microcalorimeter and a crystal spectrometer

  2. Rates and patterns of great ape retrotransposition.

    PubMed

    Hormozdiari, Fereydoun; Konkel, Miriam K; Prado-Martinez, Javier; Chiatante, Giorgia; Herraez, Irene Hernando; Walker, Jerilyn A; Nelson, Benjamin; Alkan, Can; Sudmant, Peter H; Huddleston, John; Catacchio, Claudia R; Ko, Arthur; Malig, Maika; Baker, Carl; Marques-Bonet, Tomas; Ventura, Mario; Batzer, Mark A; Eichler, Evan E

    2013-08-13

    We analyzed 83 fully sequenced great ape genomes for mobile element insertions, predicting a total of 49,452 fixed and polymorphic Alu and long interspersed element 1 (L1) insertions not present in the human reference assembly and assigning each retrotransposition event to a different time point during great ape evolution. We used these homoplasy-free markers to construct a mobile element insertions-based phylogeny of humans and great apes and demonstrate their differential power to discern ape subspecies and populations. Within this context, we find a good correlation between L1 diversity and single-nucleotide polymorphism heterozygosity (r(2) = 0.65) in contrast to Alu repeats, which show little correlation (r(2) = 0.07). We estimate that the "rate" of Alu retrotransposition has differed by a factor of 15-fold in these lineages. Humans, chimpanzees, and bonobos show the highest rates of Alu accumulation--the latter two since divergence 1.5 Mya. The L1 insertion rate, in contrast, has remained relatively constant, with rates differing by less than a factor of three. We conclude that Alu retrotransposition has been the most variable form of genetic variation during recent human-great ape evolution, with increases and decreases occurring over very short periods of evolutionary time.

  3. Evaluation of efficacy of iodine prophylaxis in Poland based on the examination of schoolchildren living in Opoczno Town (Lodz Voivodship).

    PubMed

    Zygmunt, Arkadiusz; Adamczewski, Zbigniew; Wojciechowska-Durczyńska, Katarzyna; Cyniak-Magierska, Anna; Krawczyk-Rusiecka, Kinga; Zygmunt, Agnieszka; Karbownik-Lewińska, Małgorzata; Lewiński, Andrzej

    2012-12-22

    In 1997 a currently obligatory model of iodine prophylaxis, based on mandatory iodization of household salt with 30 mg KI/kg, was introduced. The aim of our study was to assess the iodine intake among school-age children living in Opoczno in 3 subsequent time points - in 1994, before establishment of currently operating model of iodine prophylaxis, in 1999 - 2 years after implementation of iodine prophylaxis and in 2010, - 14 years after its implementation. We assessed goitre incidence and urine iodine concentration (UIC) in 104 children in 1994, 207 children in 1999 and 174 children in 2012. Age of examined children ranged from 6 to 15 years. The thyroid volumes evaluated by ultrasound were compared to reference values for thyroid volume proposed by Zimmermann at al. Moreover, we have introduced a new index - V/BSA ratio (comparison of thyroid volume to the body surface area), which to our belief allows for more accurate assessment of thyroid volume. The median of UICs was 45.5 μg/L (1994), 101.1 μg/L (1999) and 100.6 μg/L (2010). The distribution of obtained results has changed as well - iodine concentrations below 50 μg/L were present in 59.1% children in 1994, in 12.6% children - in 1999 and in 7.1% children - in 2010.Although a significant decrease in goitre incidence with regard to age - 92.6% (1994) vs 18.5% (1999) and 15.8% (2010), as well as with regard to BSA - 95.4% (1994) vs 15.2% (1999) and 11.6% (2010) was observed, it still points to the iodine deficiency, which is in contradiction with UICs as they are within normal limits. V/BSA ratio avoids such discrepancy. The values of ratio V/BSA were higher in 1994 (7.079 ± 2.775) than in 1999 (2.935 ± 1.112) (p<0.05) and in 2010 (2.846 ± 1.029) (p<0.05). Hitherto model of iodine prophylaxis has proved to be effective in eliminating the iodine deficiency. The iodine intake is now more even, homogenous, which translates into smaller scatter of UICs and less percentage of children, in whom UIC is less than 50 μg/L. However, the iodine intake only slightly exceeds the recommended values, so median of UICs oscillates around the lower limit of references values.

  4. Evaluation of efficacy of iodine prophylaxis in Poland based on the examination of schoolchildren living in Opoczno Town (Lodz Voivodship)

    PubMed Central

    2012-01-01

    Background In 1997 a currently obligatory model of iodine prophylaxis, based on mandatory iodization of household salt with 30 mg KI/kg, was introduced. The aim of our study was to assess the iodine intake among school-age children living in Opoczno in 3 subsequent time points – in 1994, before establishment of currently operating model of iodine prophylaxis, in 1999 – 2 years after implementation of iodine prophylaxis and in 2010, – 14 years after its implementation. Methods We assessed goitre incidence and urine iodine concentration (UIC) in 104 children in 1994, 207 children in 1999 and 174 children in 2012. Age of examined children ranged from 6 to 15 years. The thyroid volumes evaluated by ultrasound were compared to reference values for thyroid volume proposed by Zimmermann at al. Moreover, we have introduced a new index – V/BSA ratio (comparison of thyroid volume to the body surface area), which to our belief allows for more accurate assessment of thyroid volume. Results The median of UICs was 45.5 μg/L (1994), 101.1 μg/L (1999) and 100.6 μg/L (2010). The distribution of obtained results has changed as well – iodine concentrations below 50 μg/L were present in 59.1% children in 1994, in 12.6% children – in 1999 and in 7.1% children – in 2010. Although a significant decrease in goitre incidence with regard to age – 92.6% (1994) vs 18.5% (1999) and 15.8% (2010), as well as with regard to BSA – 95.4% (1994) vs 15.2% (1999) and 11.6% (2010) was observed, it still points to the iodine deficiency, which is in contradiction with UICs as they are within normal limits. V/BSA ratio avoids such discrepancy. The values of ratio V/BSA were higher in 1994 (7.079 ± 2.775) than in 1999 (2.935 ± 1.112) (p<0.05) and in 2010 (2.846 ± 1.029) (p<0.05). Conclusions Hitherto model of iodine prophylaxis has proved to be effective in eliminating the iodine deficiency. The iodine intake is now more even, homogenous, which translates into smaller scatter of UICs and less percentage of children, in whom UIC is less than 50 μg/L. However, the iodine intake only slightly exceeds the recommended values, so median of UICs oscillates around the lower limit of references values. PMID:23259538

  5. Hypersensitivity and desensitization to antineoplastic agents: outcomes of 189 procedures with a new short protocol and novel diagnostic tools assessment.

    PubMed

    Madrigal-Burgaleta, R; Berges-Gimeno, M P; Angel-Pereira, D; Ferreiro-Monteagudo, R; Guillen-Ponce, C; Pueyo, C; Gomez de Salazar, E; Alvarez-Cuesta, E

    2013-07-01

    Desensitization to antineoplastic agents is becoming a standard of care. Efforts to establish and improve these techniques are being made at many institutions. Our aims are to evaluate a new rapid desensitization protocol designed to be shorter (approximately 4 h) and safer (reducing hazardous drugs exposure risks) and to assess the oxaliplatin-specific immunoglobulin E (IgE) as a novel diagnostic tool. Prospective, observational, longitudinal study with patients who, for a 1-year period, suffered reactions to antineoplastic agents and were referred to the Desensitization Program at Ramon y Cajal University Hospital (RCUH). Patients were included or excluded as desensitization candidates after anamnesis, skin testing, risk assessment, and graded challenge. Specific IgE was determined in oxaliplatin-reactive patients. Candidate patients were desensitized using the new RCUH rapid desensitization protocol. Of 189 intravenous rapid desensitizations, 188 were successfully accomplished in the 23 patients who met inclusion criteria for desensitization (of 58 referred patients). No breakthrough reactions occurred in 94% of desensitizations, and most breakthrough reactions were mild. In 10 oxaliplatin-reactive patients, 38 desensitizations were successfully accomplished. Sensitivity for oxaliplatin-specific IgE was 38% (0.35UI/l cutoff point) and 54% (0.10UI/l cutoff point); specificity was 100% for both cutoff points. In the hands of a Desensitization Program, managed by drug desensitization experts, this new protocol has proven an effective therapeutic tool for hypersensitivity to several antineoplastic agents (oxaliplatin, carboplatin, paclitaxel, docetaxel, cyclophosphamide, and rituximab); moreover, it improves safety handling of hazardous drugs. We report the first large series of oxaliplatin desensitizations. Oxaliplatin-specific IgE determination could be helpful. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  6. Selected problems with boron determination in water treatment processes. Part I: comparison of the reference methods for ICP-MS and ICP-OES determinations.

    PubMed

    Kmiecik, Ewa; Tomaszewska, Barbara; Wątor, Katarzyna; Bodzek, Michał

    2016-06-01

    The aim of the study was to compare the two reference methods for the determination of boron in water samples and further assess the impact of the method of preparation of samples for analysis on the results obtained. Samples were collected during different desalination processes, ultrafiltration and the double reverse osmosis system, connected in series. From each point, samples were prepared in four different ways: the first was filtered (through a membrane filter of 0.45 μm) and acidified (using 1 mL ultrapure nitric acid for each 100 mL of samples) (FA), the second was unfiltered and not acidified (UFNA), the third was filtered but not acidified (FNA), and finally, the fourth was unfiltered but acidified (UFA). All samples were analysed using two analytical methods: inductively coupled plasma mass spectrometry (ICP-MS) and inductively coupled plasma optical emission spectrometry (ICP-OES). The results obtained were compared and correlated, and the differences between them were studied. The results show that there are statistically significant differences between the concentrations obtained using the ICP-MS and ICP-OES techniques regardless of the methods of sampling preparation (sample filtration and preservation). Finally, both the ICP-MS and ICP-OES methods can be used for determination of the boron concentration in water. The differences in the boron concentrations obtained using these two methods can be caused by several high-level concentrations in selected whole-water digestates and some matrix effects. Higher concentrations of iron (from 1 to 20 mg/L) than chromium (0.02-1 mg/L) in the samples analysed can influence boron determination. When iron concentrations are high, we can observe the emission spectrum as a double joined and overlapping peak.

  7. Reference intervals for serum reactive oxygen metabolites, biological antioxidant potential, and oxidative stress index in adult rams.

    PubMed

    Oikonomidis, Ioannis L; Kiosis, Evangelos A; Brozos, Christos N; Kritsepi-Konstantinou, Maria G

    2017-03-01

    OBJECTIVE To establish reference intervals for serum reactive oxygen metabolites (ROMs), biological antioxidant potential (BAP), and oxidative stress index (OSi) in adult rams by use of controlled preanalytic and analytic procedures. ANIMALS 123 healthy 1- to 4-year-old rams of 2 Greek breeds (Chios [n = 62] and Florina [61]). PROCEDURES 4 hours after rams were fed, a blood sample was obtained from each ram, and serum was harvested. Concentrations of ROMs and BAP were measured colorimetrically on a spectrophotometric analyzer. The OSi was calculated as ROMs concentration divided by BAP concentration. Combined and breed-specific reference intervals were calculated by use of nonparametric and robust methods, respectively. Reference intervals were defined as the 2.5th to 97.5th percentiles. RESULTS Reference intervals for ROMs, BAP, and OSi for all rams combined were 65 to 109 Carratelli units, 2,364 to 4,491 μmol/L, and 18.2 to 43.0 Carratelli units/(mmol/L), respectively. Reference intervals of Chios rams for ROMs, BAP, and OSi were 56 to 113 Carratelli units, 2,234 to 4,290 μmol/L, and 12.9 to 38.4 Carratelli units/(mmol/L), respectively. Reference intervals of Florina rams for ROMs, BAP, and OSi were 68 to 111 Carratelli units, 2,337 to 4,363 μmol/L, and 14.1 to 38.1 Carratelli units/(mmol/L), respectively. CONCLUSIONS AND CLINICAL RELEVANCE Reference intervals calculated in this study can be used as a guide for the interpretation of ROMs, BAP, and OSi results in rams and, under appropriate conditions, can be adopted for use by veterinary laboratories.

  8. Transport of chemical and microbial compounds from known wastewater discharges: Potential for use as indicators of human fecal contamination

    USGS Publications Warehouse

    Glassmeyer, S.T.; Furlong, E.T.; Kolpin, D.W.; Cahill, J.D.; Zaugg, S.D.; Werner, S.L.; Meyer, M.T.; Kryak, D.D.

    2005-01-01

    The quality of drinking and recreational water is currently (2005) determined using indicator bacteria. However, the culture tests used to analyze for these bacteria require a long time to complete and do not discriminate between human and animal fecal material sources. One complementary approach is to use chemicals found in human wastewater, which would have the advantages of (1) potentially shorter analysis times than the bacterial culture tests and (2) being selected for human-source specificity. At 10 locations, water samples were collected upstream and at two successive points downstream from a wastewaster treatment plant (WWTP); a treated effluent sample was also collected at each WWTP. This sampling plan was used to determine the persistence of a chemically diverse suite of emerging contaminants in streams. Samples were also collected at two reference locations assumed to have minimal human impacts. Of the 110 chemical analytes investigated in this project, 78 were detected at least once. The number of compounds in a given sample ranged from 3 at a reference location to 50 in a WWTP effluent sample. The total analyte load at each location varied from 0.018 μg/L at the reference location to 97.7 μg/L in a separate WWTP effluent sample. Although most of the compound concentrations were in the range of 0.01−1.0 μg/L, in some samples, individual concentrations were in the range of 5−38 μg/L. The concentrations of the majority of the chemicals present in the samples generally followed the expected trend:  they were either nonexistent or at trace levels in the upstream samples, had their maximum concentrations in the WWTP effluent samples, and then declined in the two downstream samples. This research suggests that selected chemicals are useful as tracers of human wastewater discharge.

  9. 78 FR 45592 - DeltaPoint Capital IV, LP;

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-07-29

    ... Regulations (13 CFR 107.730). DeltaPoint Capital IV, L.P. provided financing to BioMaxx, Inc., 1 Fishers Road... York), L.P., an Associate of DeltaPoint Capital IV, L.P., owns more than ten percent of BioMaxx, Inc...

  10. Carbon Dioxide Compensation Points of Flowering Plants 1

    PubMed Central

    Krenzer, Eugene G.; Moss, Dale N.; Crookston, R. Kent

    1975-01-01

    Carbon dioxide compensation points of several hundred species of monocotyledons and dicotyledons have been measured during the course of various experiments in our laboratory over a period of several years. These have been classified into two groups: high, compensation points of 40 μl/l or greater; and low, compensation points of 10 μl/l or less. They are listed alphabetically both by families and species for monocotyledons and dicotyledons. Only two species did not unequivocally fit into the above established groups. These were Moricandia arvensis (L.) DC., which had an average compensation point of 26 μl/l and Panicum milioides Nees ex Trin., which was variable, but most often equilibrated between 12 to 20 μl/l CO2. PMID:16659272

  11. Reference Intervals of Routine Coagulation Assays During the Pregnancy and Puerperium Period.

    PubMed

    Gong, Jiao-Mei; Shen, Yong; He, Yan-Xia

    2016-11-01

    Significant changes occur in the coagulation and fibrinolytic systems during pregnancy and puerperium in the plasma levels. However, reference ranges based on healthy people are not optimal for informing clinical decisions during the pregnancy and puerperium. Therefore, it is essential to explore coagulation assays' reference ranges during the pregnancy and puerperium. Prothrombin time (PT), activated partial thromboplastin time (APTT), thrombin time (TT), fibrinogen (Fib.), and D-dimer were all measured according to the manufacturer's specifications and laboratory standard operating procedure of the STA-R evolution coagulation analyzer. A total of 11,601 women were enrolled in this study. The reference ranges for PT, APTT, TT, Fib., and D-dimer in nonpregnancy period were 10.87-13.76 s, 29.22-44.61 s, 15.39-20.15 s, 1.59-3.97 g/l, and 0-0.56 mg/l, respectively. In early-pregnancy period, the ranges were 11.14-14.07 s, 29.97-44.69 s, 14.92-19.03 s, 1.98-4.13 g/l, and 0-1.67 mg/l, respectively. In midpregnancy period, the ranges were 9.98-12.84 s, 28.53-40.70 s, 13.51-19.82 s, 2.63-5.19 g/l, and 0-2.81 mg/l, respectively. In late-pregnancy period, the ranges were 9.48-12.58 s, 28.61-40.80 s, 14.10-19.61 s, 2.80-5.56 g/l, and 0-27.08 mg/l, respectively. In puerperium period, the ranges were 10.85-13.72 s, 30.51-43.02 s, 15.31-19.64 s, 1.14-5.07 g/l, and 1.27-4.85 mg/l, respectively. We presented reference intervals for coagulation assays from the nonpregnancy to puerperium period that can be adopted in other laboratories after further validation. © 2016 Wiley Periodicals, Inc.

  12. Model reference adaptive control for the azimuth-pointing system of a balloon-borne stabilized platform

    NASA Technical Reports Server (NTRS)

    Lubin, Philip M.; Tomizuka, Masayoshi; Chingcuanco, Alfredo O.; Meinhold, Peter R.

    1991-01-01

    A balloon-born stabilized platform has been developed for the remotely operated altitude-azimuth pointing of a millimeter wave telescope system. This paper presents a development and implementation of model reference adaptive control (MRAC) for the azimuth-pointing system of the stabilized platform. The primary goal of the controller is to achieve pointing rms better than 0.1 deg. Simulation results indicate that MRAC can achieve pointing rms better than 0.1 deg. Ground test results show pointing rms better than 0.03 deg. Data from the first flight at the National Scientific Balloon Facility (NSBF) Palestine, Texas show pointing rms better than 0.02 deg.

  13. Accuracy of Automatic Cephalometric Software on Landmark Identification

    NASA Astrophysics Data System (ADS)

    Anuwongnukroh, N.; Dechkunakorn, S.; Damrongsri, S.; Nilwarat, C.; Pudpong, N.; Radomsutthisarn, W.; Kangern, S.

    2017-11-01

    This study was to assess the accuracy of an automatic cephalometric analysis software in the identification of cephalometric landmarks. Thirty randomly selected digital lateral cephalograms of patients undergoing orthodontic treatment were used in this study. Thirteen landmarks (S, N, Or, A-point, U1T, U1A, B-point, Gn, Pog, Me, Go, L1T, and L1A) were identified on the digital image by an automatic cephalometric software and on cephalometric tracing by manual method. Superimposition of printed image and manual tracing was done by registration at the soft tissue profiles. The accuracy of landmarks located by the automatic method was compared with that of the manually identified landmarks by measuring the mean differences of distances of each landmark on the Cartesian plane where X and Y coordination axes passed through the center of ear rod. One-Sample T test was used to evaluate the mean differences. Statistically significant mean differences (p<0.05) were found in 5 landmarks (Or, A-point, Me, L1T, and L1A) in horizontal direction and 7 landmarks (Or, A-point, U1T, U1A, B-point, Me, and L1A) in vertical direction. Four landmarks (Or, A-point, Me, and L1A) showed significant (p<0.05) mean differences in both horizontal and vertical directions. Small mean differences (<0.5mm) were found for S, N, B-point, Gn, and Pog in horizontal direction and N, Gn, Me, and L1T in vertical direction. Large mean differences were found for A-point (3.0 < 3.5mm) in horizontal direction and L1A (>4mm) in vertical direction. Only 5 of 13 landmarks (38.46%; S, N, Gn, Pog, and Go) showed no significant mean difference between the automatic and manual landmarking methods. It is concluded that if this automatic cephalometric analysis software is used for orthodontic diagnosis, the orthodontist must correct or modify the position of landmarks in order to increase the accuracy of cephalometric analysis.

  14. Classification of Swedish Learner Essays by CEFR Levels

    ERIC Educational Resources Information Center

    Volodina, Elena; Pilán, Ildikó; Alfter, David

    2016-01-01

    The paper describes initial efforts on creating a system for the automatic assessment of Swedish second language (L2) learner essays from two points of view: holistic evaluation of the reached level according to the Common European Framework of Reference (CEFR), and the lexical analysis of texts for receptive and productive vocabulary per CEFR…

  15. Polluted rainwater runoff from waste recovery and recycling companies: Determination of emission levels associated with the best available techniques.

    PubMed

    Huybrechts, D; Verachtert, E; Vander Aa, S; Polders, C; Van den Abeele, L

    2016-08-01

    Rainwater falling on outdoor storage areas of waste recovery and recycling companies becomes polluted via contact with the stored materials. It contains various pollutants, including heavy metals, polycyclic aromatic hydrocarbons and polychlorinated biphenyls, and is characterized by a highly fluctuating composition and flow rate. This polluted rainwater runoff is legally considered as industrial wastewater, and the polluting substances contained in the rainwater runoff at the point of discharge, are considered as emissions into water. The permitting authorities can set emission limit values (discharge limits) at the point of discharge. Best available techniques are an important reference point for setting emission limit values. In this paper, the emission levels associated with the best available techniques for dealing with polluted rainwater runoff from waste recovery and recycling companies were determined. The determination is based on an analysis of emission data measured at different companies in Flanders. The data show that a significant fraction of the pollution in rainwater runoff is associated with particles. A comparison with literature data provides strong indications that not only leaching, but also atmospheric deposition play an important role in the contamination of rainwater at waste recovery and recycling companies. The prevention of pollution and removal of suspended solids from rainwater runoff to levels below 60mg/l are considered as best available techniques. The associated emission levels were determined by considering only emission data from plants applying wastewater treatment, and excluding all samples with suspended solid levels >60mg/l. The resulting BAT-AEL can be used as a reference point for setting emission limit values for polluted rainwater runoff from waste recovery and recycling companies. Since the BAT-AEL (e.g. 150μg/l for Cu) are significantly lower than current emission levels (e.g. 300μg/l as the 90% percentile and 4910μg/l as the maximum level for Cu), this will result in a significant reduction in emissions into water. Copyright © 2016 Elsevier Ltd. All rights reserved.

  16. Determination of strong ion gap in healthy dogs.

    PubMed

    Fettig, Pamela K; Bailey, Dennis B; Gannon, Kristi M

    2012-08-01

    To determine and compare reference intervals of the strong ion gap (SIG) in a group of healthy dogs determined with 2 different equations. Prospective observational study. Tertiary referral and teaching hospital. Fifty-four healthy dogs. None. Serum biochemistry and blood gas analyses were performed for each dog. From these values, SIG was calculated using 2 different equations: SIG(1) = SID(a) {[Na (+)] + [K(+)] - [Cl(-)]+ [2 × Ca(2+)] + [2 × Mg(2+)] - [L-lactate]}- SID(e) {TCO(2) + A(-)} and SIG(2) = [albumin] × 4.9-anion gap. Reference intervals were established for each SIG equation using the mean ± 1.96 × standard deviation (SD). For SIG(1), the median was 7.13 mEq/L (range, 1.05-11.30 mEq/L) and the derived reference interval was 1.85-10.61 mEq/L. Median SIG(2) was -0.22 mEq/L (range, -5.34-6.61 mEq/L) and the mean SIG(2) was -0.09 mEq/L (95% confidence interval for the mean, -0.82-0.65 mEq/L). The derived reference interval was -5.36-5.18 mEq/L. The results of the SIG calculations were significantly different (P < 0.0001) between the 2 equations used. The 2 equations used to calculate SIG yielded significantly different results and cannot be used interchangeably. The authors believe SIG(2) to be a more accurate reflection of acid-base status in healthy dogs, and recommend that this calculation be used for future studies. © Veterinary Emergency and Critical Care Society 2012.

  17. 46,XY hypergonadotropic hypogonadism and myasthenia gravis.

    PubMed

    Lichiardopol, Corina; Herlea, V; Ioan, Virginia; Tomulescu, V; Mixich, F

    2006-01-01

    Both hypergonadotropic hypogonadism and myasthenia gravis can be parts of type II autoimmune polyendocrine syndrome and association between the two disorders has been reported in few cases. A 14 year old male patient with a personal history of bilateral cryptorchidism and ptosis was referred for delayed puberty. Clinical examination revealed eunuchoid habitus, small, soft testes, gynecomastia, ptosis, a myasthenic deficit score of 22.5 points and an IQ of 84 points. Decreased testosterone (0.064 ng/mL) and elevated LH (64.5 mUI/mL) were consistent with hypergonadotropic hypogonadism and karyotype was normal: 46,XY. Thyroid function, haematologic evaluation, BUN, electrolytes, and glycemia were in the normal range. Therapy consisted of anticholinesterase inhibitors, immunosuppressants, corticotherapy, testosterone; thoracoscopic thymectomy was performed showing thymic lymphoid hyperplasia on histopathologic examination. Myasthenic score improved (12.5 points), progressive virilization occurred, and a year later the patient presented with cushingoid features and obesity.

  18. L-glutamine is a key parameter in the immunosuppression phenomenon

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hammami, Ines; Chen, Jingkui; Bronte, Vincenzo

    2012-09-07

    Highlights: Black-Right-Pointing-Pointer The absence of L-Gln inhibited iNOS activity, but not ARG1 one. Black-Right-Pointing-Pointer MSC-1 cells were able to inhibit Jurkat cell growth, but not their viability. Black-Right-Pointing-Pointer Absence of L-Gln down-regulated central carbon metabolism and L-Arg recycling. Black-Right-Pointing-Pointer Absence of L-Gln deteriorated cell bioenergetic status. Black-Right-Pointing-Pointer L-Gln is crucial for iNOS-mediated immunosuppression activity. -- Abstract: Suppression of tumour-specific T-cell functions by myeloid-derived suppressor cells (MDSCs) is a dominant mechanism of tumour escape. MDSCs express two enzymes, i.e. inducible nitric oxide synthase (iNOS) and arginase (ARG1), which metabolize the semi-essential amino acid L-arginine (L-Arg) whose bioavailability is crucial for T-cellmore » proliferation and functions. Recently, we showed that glutaminolysis supports MDSC maturation process by ensuring the supply of intermediates and energy. In this work, we used an immortalized cell line derived from mouse MDSCs (MSC-1 cell line) to further investigate the role of L-glutamine (L-Gln) in the maintenance of MDSC immunosuppressive activity. Culturing MSC-1 cells in L-Gln-limited medium inhibited iNOS activity, while ARG1 was not affected. MSC-1 cells inhibited Jukat cell growth without any noticeable effect on their viability. The characterization of MSC-1 cell metabolic profile revealed that L-Gln is an important precursor of lactate production via the NADP{sup +}-dependent malic enzyme, which co-produces NADPH. Moreover, the TCA cycle activity was down-regulated in the absence of L-Gln and the cell bioenergetic status was deteriorated accordingly. This strongly suggests that iNOS activity, but not that of ARG1, is related to an enhanced central carbon metabolism and a high bioenergetic status. Taken altogether, our results suggest that the control of glutaminolysis fluxes may represent a valuable target for immunotherapy.« less

  19. Accumulation of perfluorinated compounds in captive Bengal tigers (Panthera tigris tigris) and African lions (Panthera leo Linnaeus) in China.

    PubMed

    Li, Xuemei; Yeung, Leo Wai Yin; Taniyasu, Sachi; Lam, Paul K S; Yamashita, Nobuyoshi; Xu, Muqi; Dai, Jiayin

    2008-11-01

    The accumulation of perfluorinated compounds (PFCs) in the sera of captive wildlife species Bengal tigers (Panthera tigris tigris) and African lions (Panthera leo Linnaeus) from Harbin Wildlife Park, Heilongjiang Province, in China were analyzed by high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS). Perfluorooctanesulfonate (PFOS) was the predominant contaminant with a mean serum concentration of 1.18 ng mL(-1) in tigers and 2.69 ng mL(-1) in lions. Perfluorononanoic acid (PFNA) was the second most prevalent contaminant in both species. The composition profiles of the tested PFCs differed between tigers and lions, and the percentages of perfluorooctanoic acid (PFOA) were greater in lions than in tigers, indicating different exposures and/or metabolic capabilities between the two species. Assessments of the risk of PFC contamination to the two species were obtained by comparing measured concentrations to points of departure or toxicity reference values (TRVs). Results suggest no risk of PFOS exposure or toxicity for the two species.

  20. Comparison between B·R·A·H·M·S PCT direct, a new sensitive point-of-care testing device for rapid quantification of procalcitonin in emergency department patients and established reference methods - a prospective multinational trial.

    PubMed

    Kutz, Alexander; Hausfater, Pierre; Oppert, Michael; Alan, Murat; Grolimund, Eva; Gast, Claire; Alonso, Christine; Wissmann, Christoph; Kuehn, Christian; Bernard, Maguy; Huber, Andreas; Mueller, Beat; Schuetz, Philipp

    2016-04-01

    Procalcitonin (PCT) is increasingly being used for the diagnostic and prognostic work up of patients with suspected infections in the emergency department (ED). Recently, B·R·A·H·M·S PCT direct, the first high sensitive point-of-care test (POCT), has been developed for fast PCT measurement on capillary or venous blood samples. This is a prospective, international comparison study conducted in three European EDs. Consecutive patients with suspicion of bacterial infection were included. Duplicate determination of PCT was performed in capillary (fingertip) and venous whole blood (EDTA), and compared to the reference method. The diagnostic accuracy was evaluated by correlation and concordance analyses. Three hundred and three patients were included over a 6-month period (60.4% male, median age 65.2 years). The correlation between capillary or venous whole blood and the reference method was excellent: r2=0.96 and 0.97, sensitivity 88.1% and 93.0%, specificity 96.5% and 96.8%, concordance 93% and 95%, respectively at a 0.25 μg/L threshold. No significant bias was observed (-0.04 and -0.02 for capillary and venous whole blood) although there were 6.8% and 5.1% outliers, respectively. B·R·A·H·M·S PCT direct had a shorter time to result as compared to the reference method (25 vs. 144 min, difference 119 min, 95% CI 110-134 min, p<0.0001). This study found a high diagnostic accuracy and a faster time to result of B·R·A·H·M·S PCT direct in the ED setting, allowing shortening time to therapy and a more wide-spread use of PCT.

  1. Front end for GPS receivers

    NASA Technical Reports Server (NTRS)

    Thomas, Jr., Jess Brooks (Inventor)

    1999-01-01

    The front end in GPS receivers has the functions of amplifying, down-converting, filtering and sampling the received signals. In the preferred embodiment, only two operations, A/D conversion and a sum, bring the signal from RF to filtered quadrature baseband samples. After amplification and filtering at RF, the L1 and L2 signals are each sampled at RF at a high selected subharmonic rate. The subharmonic sample rates are approximately 900 MHz for L1 and 982 MHz for L2. With the selected subharmonic sampling, the A/D conversion effectively down-converts the signal from RF to quadrature components at baseband. The resulting sample streams for L1 and L2 are each reduced to a lower rate with a digital filter, which becomes a straight sum in the simplest embodiment. The frequency subsystem can be very simple, only requiring the generation of a single reference frequency (e.g. 20.46 MHz minus a small offset) and the simple multiplication of this reference up to the subharmonic sample rates for L1 and L2. The small offset in the reference frequency serves the dual purpose of providing an advantageous offset in the down-converted carrier frequency and in the final baseband sample rate.

  2. Assessment of reference gene stability in Rice stripe virus and Rice black streaked dwarf virus infection rice by quantitative Real-time PCR.

    PubMed

    Fang, Peng; Lu, Rongfei; Sun, Feng; Lan, Ying; Shen, Wenbiao; Du, Linlin; Zhou, Yijun; Zhou, Tong

    2015-10-24

    Stably expressed reference gene(s) normalization is important for the understanding of gene expression patterns by quantitative Real-time PCR (RT-qPCR), particularly for Rice stripe virus (RSV) and Rice black streaked dwarf virus (RBSDV) that caused seriously damage on rice plants in China and Southeast Asia. The expression of fourteen common used reference genes of Oryza sativa L. were evaluated by RT-qPCR in RSV and RBSDV infected rice plants. Suitable normalization reference gene(s) were identified by geNorm and NormFinder algorithms. UBQ 10 + GAPDH and UBC + Actin1 were identified as suitable reference genes for RT-qPCR normalization under RSV and RBSDV infection, respectively. When using multiple reference genes, the expression patterns of OsPRIb and OsWRKY, two virus resistance genes, were approximately similar with that reported previously. Comparatively, by using single reference gene (TIP41-Like), a weaker inducible response was observed. We proposed that the combination of two reference genes could obtain more accurate and reliable normalization of RT-qPCR results in RSV- and RBSDV-infected plants. This work therefore sheds light on establishing a standardized RT-qPCR procedure in RSV- and RBSDV-infected rice plants, and might serve as an important point for discovering complex regulatory networks and identifying genes relevant to biological processes or implicated in virus.

  3. Bioequivalence of generic alendronate sodium tablets (70 mg) to Fosamax® tablets (70 mg) in fasting, healthy volunteers: a randomized, open-label, three-way, reference-replicated crossover study

    PubMed Central

    Zhang, Yifan; Chen, Xiaoyan; Tang, Yunbiao; Lu, Youming; Guo, Lixia; Zhong, Dafang

    2017-01-01

    Purpose The aim of this study was to evaluate the bioequivalence of a generic product 70 mg alendronate sodium tablets with the reference product Fosamax® 70 mg tablet. Materials and methods A single-center, open-label, randomized, three-period, three-sequence, reference-replicated crossover study was performed in 36 healthy Chinese male volunteers under fasting conditions. In each study period, the volunteers received a single oral dose of the generic or reference product (70 mg). Blood samples were collected at pre-dose and up to 8 h after administration. The bioequivalence of the generic product to the reference product was assessed using the US Food and Drug Administration (FDA) and European Medicines Agency (EMA) reference-scaled average bioequivalence (RSABE) methods. Results The average maximum concentrations (Cmax) of alendronic acid were 64.78±43.76, 56.62±31.95, and 60.15±37.12 ng/mL after the single dose of the generic product and the first and second doses of the reference product, respectively. The areas under the plasma concentration–time curves from time 0 to the last timepoint (AUC0–t) were 150.36±82.90, 148.15±85.97, and 167.11±110.87 h⋅ng/mL, respectively. Reference scaling was used because the within-subject standard deviations of the reference product (sWR) for Cmax and AUC0–t were all higher than the cutoff value of 0.294. The 95% upper confidence bounds were −0.16 and −0.17 for Cmax and AUC0–t, respectively, and the point estimates for the generic/reference product ratio were 1.08 and 1.00, which satisfied the RSABE acceptance criteria of the FDA. The 90% CIs for Cmax and AUC0–t were 90.35%–129.04% and 85.31%–117.15%, respectively, which were within the limits of the EMA for the bioequivalence of 69.84%–143.19% and 80.00%–125.00%. Conclusion The generic product was bioequivalent to the reference product in terms of the rate and extent of alendronate absorption after a single 70 mg oral dose under fasting conditions. PMID:28744102

  4. Effect of 6-8 weeks of oral ursodeoxycholic acid administration on serum concentrations of fasting and postprandial bile acids and biochemical analytes in healthy dogs.

    PubMed

    Deitz, Krysta L; Makielski, Kelly M; Williams, Jackie M; Lin, Hui; Morrison, Jo Ann

    2015-09-01

    Ursodeoxycholic acid (UDCA) is commonly used for the treatment of hepatobiliary disease. UDCA is a bile acid that can be detected in the bile acid assay. Its effect on biochemical analytes is unknown. The aim of this study was to determine the effect of 6-8 weeks of UDCA administration on fasting and postprandial concentrations of serum bile acids (SBA), cholesterol, triglycerides, bilirubin, and liver enzyme activities in healthy dogs. Twenty healthy dogs received UDCA for 6-8 weeks. CBC, biochemistry profile, urinalysis, fasting and postprandial SBA, and hepatobiliary ultrasound examination were performed prior to starting UDCA (timepoint 0) and after 6-8 weeks of therapy, while animals were still receiving UDCA (timepoint 1). Timepoint 0 and timepoint 1 values were compared with a paired t-test. SBA were remeasured 72 hours after UDCA discontinuation. Only mean fasting SBA at timepoint 1 increased significantly (P = .03) from timepoint 0 (2.26 μmol/L at time 0 and 3.81 μmol/L at time 1) but were not elevated above the normal reference interval (0-9 μmol/L). Two dogs had timepoint 1 fasting SBA above the reference interval (10 and 11.7 μmol/L). One dog had timepoint 1 postprandial SBA above the reference interval at 20.1 μmol/L (reference interval 0-17 μmol/L). Repeat SBA 72 hours after UDCA discontinuation were normal. Long-term administration of UDCA to healthy dogs may increase fasting SBA above pretreatment values (typically within the reference interval). Long-term administration of UDCA to healthy dogs does not alter liver enzyme activities, and bilirubin, cholesterol, or triglyceride concentrations. © 2015 American Society for Veterinary Clinical Pathology.

  5. Magnitudes, nature, and effects of point and nonpoint discharges in the Chattahoochee River Basin, Atlanta to West Point Dam, Georgia

    USGS Publications Warehouse

    Stamer, J.K.; Cherry, Rodney N.; Faye, R.E.; Kleckner, R.L.

    1979-01-01

    During the period April 1975 to June 1978, the U.S. Geological Survey conducted a river-quality assessment of the Upper Chattahoochee River basin in Georgia. One objective of the study was to assess the magnitudes, nature, and effects of point and non-point discharges in the Chattahoochee River basin from Atlanta to the West Point Dam. On an average annual basis and during the storm period of March 1215, 1976, non-point-source loads for most constituents analyzed were larger than point-source loads at the Whitesburg station, located on the Chattahoochee River about 40 river miles downstream of Atlanta. Most of the non-point-source constituent loads in the Atlanta-to-Whitesburg reach were from urban areas. Average annual point-source discharges accounted for about 50 percent of the dissolved nitrogen, total nitrogen, and total phosphorus loads, and about 70 percent of the dissolved phosphorus loads at Whitesburg. During weekends, power generation at the upstream Buford Dam hydroelectric facility is minimal. Streamflow at the Atlanta station during dry-weather weekends is estimated to be about 1,200 ft3/s (cubic feet per second). Average daily dissolved-oxygen concentrations of less than 5.0 mg/L (milligrams per liter) occurred often in the river, about 20 river miles downstream from Atlanta during these periods from May to November. During a low-flow period, June 1-2, 1977, five municipal point sources contributed 63 percent of the ultimate biochemical oxygen demand, 97 percent of the ammonium nitrogen, 78 percent of the total nitrogen, and 90 percent of the total phosphorus loads at the Franklin station, at the upstream end of West Point Lake. Average daily concentrations of 13 mg/L of ultimate biochemical oxygen demand and 1.8 mg/L of ammonium nitrogen were observed about 2 river miles downstream from two of the municipal point sources. Carbonaceous and nitrogenous oxygen demands caused dissolved-oxygen concentrations between 4.1 and 5.0 mg/L to occur in a 22-mile reach of the river downstream from Atlanta. Nitrogenous oxygen demands were greater than carbonaceous oxygen demands in the reach from river mile 303 to 271, and carbonaceous demands were greater from river mile 271 to 235. The heat load from the Atkinson-McDonough thermoelectric power-plants caused a decrease in the dissolved-oxygen concentrations of about 0.2 mg/L. During a critical low-flow period, a streamflow at Atlanta of about 1,800 ft3/s, with present (1977) point-source flows of 185 ft3/s containing concentrations of 45 mg/L of ultimate biochemical oxygen demand and 15 mg/L of ammonium nitrogen, results in a computed minimum dissolved-oxygen concentration of 4.7 mg/L in the river downstream from Atlanta. In the year 2000, a streamflow at Atlanta of about 1,800 ft3/s with point-source flows of 373 ft3/s containing concentrations of 45 mg/L of ultimate biochemical oxygen demand and 5.0 mg/L of ammonium nitrogen, will result in a computed minimum dissolved-oxygen concentration of 5.0 mg/L. A streamflow of about 1,050 ft3/s at Atlanta in the year 2000 will result in a dissolved-oxygen concentration of 5.0 mg/L if point-source flows contain concentrations of 15 mg/L of ultimate biochemical oxygen demand and 5.0 mg/L of ammonium nitrogen. Phytoplankton concentrations in West Point Lake, about 70 river miles downstream from Atlanta, could exceed 3 million cells per milliliter during extended low-flow periods in the summer with present point- and non-point-source nitrogen and phosphorus loads. In the year 2000, phytoplankton concentrations in West Point Lake are not likely to exceed 700,000 cells per milliliter during extended low-flow periods in the summer, if phosphorus concentrations do not exceed 1.0 mg/L in point-source discharges.

  6. Handwriting assessment of Franco-Quebec primary school-age students

    PubMed

    Couture, Mélanie; Morin, Marie-France; Coallier, Mélissa; Lavigne, Audrey; Archambault, Patricia; Bolduc, Émilie; Chartier, Émilie; Liard, Karolane; Jasmin, Emmanuelle

    2016-12-01

    Reasons for referring school-age children to occupational therapy mainly relate to handwriting problems. However, there are no validated tools or reference values for assessing handwriting in francophone children in Canada. This study aimed to adapt and validate the writing tasks described in an English Canadian handwriting assessment protocol and to develop reference values for handwriting speed for francophone children. Three writing tasks from the Handwriting Assessment Protocol-2nd Edition (near-point and far-point copying and dictation) were adapted for Québec French children and administered to 141 Grade 1 ( n = 73) and Grade 2 ( n = 68) students. Reference values for handwriting speed were obtained for near point and far point copying tasks. This adapted protocol and these reference values for speed will improve occupational therapy handwriting assessments for the target population.

  7. Iron Compounds and the Color of Soils in the Sakhalin Island

    NASA Astrophysics Data System (ADS)

    Vodyanitskii, Yu. N.; Kirillova, N. P.; Manakhov, D. V.; Karpukhin, M. M.

    2018-02-01

    Numerical parameters of soil color were studied according to the CIE-L*a*b color system before and after the Tamm's and Mehra-Jackson's treatments; we also determined the total Fe content in the samples from the main genetic horizons of the alluvial gray-humus soil, two profiles of burozems, and two profiles of podzols in the Sakhalin Island. In the analyzed samples, the numerical color parameters L* (lightness), a* (redness) and b* (yellowness) are found to vary within 46-73, 3-11, and 8-28, respectively. A linear relationship is revealed between the numerical values of a* parameters and Fe content in the Mehra-Jackson extracts; the regression equations are derived with the determination coefficients ( R 2): 0.49 (typical burozem), 0.79 (podzolized burozem), 0.96 (shallow-podzolic mucky podzol), 0.98 (gray-humus gley alluvial soil). For the surface-podzolic mucky podzol contaminated with petroleum hydrocarbons, R 2 was equal to only 0.03. In the gray humus (AY) and structural-metamorphic (BM) horizons of the studied soils, a* and b* parameters decrease after their treatment with the Tamm's reagent by 2 points on average. After the Mehra-Jackson treatment, the a* parameter decreased by 6 (AY) and 8 (BM) points; whereas b* parameter, by 10 and 15 points, respectively. In the E horizons of podzols, the Tamm's treatment increased a* and b* parameters by 1 point; whereas the Mehra-Jackson's treatment decreased these parameters by only 1 and 3 points, respectively. The redness (a*) decreased maximally in the lower gley horizon of the alluvial gray humus soil, i.e., by 6 (in the Tamm's extract) and 10 points (in the Mehra-Jackson's) extract. Yellowness (b*) decreased by 12 and 17 points, respectively. The revealed color specifics in the untreated samples and the color transformation under the impact of reagents in the studied soils and horizons may serve as an additional parameter that characterizes quantitatively the object of investigation in the reference databases.

  8. Oncogenic osteomalacia due to FGF23-expressing colon adenocarcinoma.

    PubMed

    Leaf, David E; Pereira, Renata C; Bazari, Hasan; Jüppner, Harald

    2013-03-01

    Oncogenic osteomalacia, a paraneoplastic syndrome associated with hypophosphatemia due to increased urinary phosphate excretion, is caused by excessive synthesis and secretion of fibroblast growth factor 23 (FGF23), a phosphaturic hormone that is normally produced by osteocytes. Most cases of oncogenic osteomalacia have been associated with benign tumors of bone or soft tissue; however, whether malignant neoplasms can also produce and secrete FGF23 is currently unknown. The aim was to determine whether a malignant neoplasm could cause oncogenic osteomalacia through excessive production and secretion of FGF23. We describe an 80-year-old woman with stage IV colon adenocarcinoma who presented with severe hypophosphatemia (0.4 mg/dL; reference, 2.6-4.5 mg/dL). Fractional excretion of phosphate was 34% (reference, <5% in the setting of hypophosphatemia), and plasma levels of FGF23 were highly elevated at 674 RU/mL (reference, <180 RU/mL). Immunohistochemical analysis of the patient's tumor showed strong staining for FGF23. Genetic analyses revealed a point mutation in the KRAS gene. We present the first case in which a malignant neoplasm is documented to produce and secrete FGF23, leading to renal phosphate-wasting. Oncogenic osteomalacia should be considered in the differential diagnosis for patients with a malignant tumor who present with hypophosphatemia.

  9. Oncogenic Osteomalacia due to FGF23-Expressing Colon Adenocarcinoma

    PubMed Central

    Pereira, Renata C.; Bazari, Hasan; Jüppner, Harald

    2013-01-01

    Context: Oncogenic osteomalacia, a paraneoplastic syndrome associated with hypophosphatemia due to increased urinary phosphate excretion, is caused by excessive synthesis and secretion of fibroblast growth factor 23 (FGF23), a phosphaturic hormone that is normally produced by osteocytes. Most cases of oncogenic osteomalacia have been associated with benign tumors of bone or soft tissue; however, whether malignant neoplasms can also produce and secrete FGF23 is currently unknown. Objective: The aim was to determine whether a malignant neoplasm could cause oncogenic osteomalacia through excessive production and secretion of FGF23. Setting: We describe an 80-year-old woman with stage IV colon adenocarcinoma who presented with severe hypophosphatemia (0.4 mg/dL; reference, 2.6–4.5 mg/dL). Results: Fractional excretion of phosphate was 34% (reference, <5% in the setting of hypophosphatemia), and plasma levels of FGF23 were highly elevated at 674 RU/mL (reference, <180 RU/mL). Immunohistochemical analysis of the patient's tumor showed strong staining for FGF23. Genetic analyses revealed a point mutation in the KRAS gene. Conclusions: We present the first case in which a malignant neoplasm is documented to produce and secrete FGF23, leading to renal phosphate-wasting. Oncogenic osteomalacia should be considered in the differential diagnosis for patients with a malignant tumor who present with hypophosphatemia. PMID:23393166

  10. Validation of a modification to Performance-Tested Method 070601: Reveal Listeria Test for detection of Listeria spp. in selected foods and selected environmental samples.

    PubMed

    Alles, Susan; Peng, Linda X; Mozola, Mark A

    2009-01-01

    A modification to Performance-Tested Method (PTM) 070601, Reveal Listeria Test (Reveal), is described. The modified method uses a new media formulation, LESS enrichment broth, in single-step enrichment protocols for both foods and environmental sponge and swab samples. Food samples are enriched for 27-30 h at 30 degrees C and environmental samples for 24-48 h at 30 degrees C. Implementation of these abbreviated enrichment procedures allows test results to be obtained on a next-day basis. In testing of 14 food types in internal comparative studies with inoculated samples, there was a statistically significant difference in performance between the Reveal and reference culture [U.S. Food and Drug Administration's Bacteriological Analytical Manual (FDA/BAM) or U.S. Department of Agriculture-Food Safety and Inspection Service (USDA-FSIS)] methods for only a single food in one trial (pasteurized crab meat) at the 27 h enrichment time point, with more positive results obtained with the FDA/BAM reference method. No foods showed statistically significant differences in method performance at the 30 h time point. Independent laboratory testing of 3 foods again produced a statistically significant difference in results for crab meat at the 27 h time point; otherwise results of the Reveal and reference methods were statistically equivalent. Overall, considering both internal and independent laboratory trials, sensitivity of the Reveal method relative to the reference culture procedures in testing of foods was 85.9% at 27 h and 97.1% at 30 h. Results from 5 environmental surfaces inoculated with various strains of Listeria spp. showed that the Reveal method was more productive than the reference USDA-FSIS culture procedure for 3 surfaces (stainless steel, plastic, and cast iron), whereas results were statistically equivalent to the reference method for the other 2 surfaces (ceramic tile and sealed concrete). An independent laboratory trial with ceramic tile inoculated with L. monocytogenes confirmed the effectiveness of the Reveal method at the 24 h time point. Overall, sensitivity of the Reveal method at 24 h relative to that of the USDA-FSIS method was 153%. The Reveal method exhibited extremely high specificity, with only a single false-positive result in all trials combined for overall specificity of 99.5%.

  11. Shear-wave seismic reflection imaging and impedance inversion for a near-surface point-bar

    NASA Astrophysics Data System (ADS)

    Benton, N. W.; Morrison, M.; Lorenzo, J. M.; Odom, B.; Clift, P. D.; Olson, E.; Gostic, A.

    2017-12-01

    Imaging and inversion of SH-waves are useful to detect, map, and quantitatively characterize near-surface point-bar strata. We conduct a horizontally-polarized (SH) reflection survey across and along a near-surface (9 - 40 m) downstream point-bar. We invert for shear-impedance profiles and correlate our interpretation to electrical conductivity (EC) logs in adjacent wells to study the internal architecture and lithology of point-bars. We acquire two common-midpoint (CMP) SH-wave seismic reflection lines at False River (Point Coupee Parish, Louisiana). A 104 m long seismic line (L1) is oriented orthogonal (NW - SE) to point-bar strike. A second line (L2) is 48 m long and set parallel to point-bar strike (NE - SW). Two EC wells lie 33 m apart. Both wells are parallel with respect to the L1 survey and offset from it by 15 m. EC log measurements range from 1 - 25 m depth. Interference of Love-waves prevents seismic imaging at depths less than 9 m. The L1 and L2 data sets are inverted for shear-impedance using a model-based band-limited impedance (BLIMP) algorithm that incorporates a low-frequency velocity model. This model is also used for the depthing processing. The L1 cross-section shows coherent dipping reflection events ( 4 - 7º) from 0.15 - 0.35 s (10 - 40 m). The corresponding shear-impedance profile also reveals coherent and dipping impedance contrasts that grow in magnitude with increasing depth. The L2 cross-section shows comparatively less dip ( 1º) as well as sharper and shallower continuity of reflection events (0.1 - 0.28 s TWT or 9 - 25 m). Depth-converted (TVD) seismic amplitudes and impedance values correlate to near-surface point-bar geology via superposition of log data. The first well (W5) shows distinct EC local maxima (+50 - 70 mS/m) at 14.5 and 15.5 m depth that correlate well with the seismic amplitudes and impedance values from both L1 and L2 data sets. The second well (W7) shows comparatively lower local maxima (+40 - 60 mS/m) but at greater depths (15.5 and 16.5 m). W5 correlates better with the seismic cross-section and impedance profile from L2 at 10, 12.5, 14.5, 15.5, and 19 m depth. EC maxima align with distinct shear-impedance values for L1 and L2 profiles. Our results provide a new and useful perspective of remotely analyzing the architecture and lithological properties of near-surface point-bars.

  12. What Variables Condition Syntactic Transfer? A Look at the L3 Initial State

    ERIC Educational Resources Information Center

    Rothman, Jason; Cabrelli Amaro, Jennifer

    2010-01-01

    This study investigates transfer at the third-language (L3) initial state, testing between the following possibilities: (1) the first language (L1) transfer hypothesis (an L1 effect for all adult acquisition), (2) the second language (L2) transfer hypothesis, where the L2 blocks L1 transfer (often referred to in the recent literature as the "L2…

  13. Theory of high-TC superconductivity: transition temperature

    NASA Astrophysics Data System (ADS)

    Harshman, Dale R.; Fiory, Anthony T.; Dow, John D.

    2010-12-01

    After reading over our published manuscript, we noticed that the discussion concerning the determination of σ for the ruthenate Ba2YRu0.9Cu0.1O6 in section 2.3.1 (3rd paragraph) is somewhat terse. Herein we provide an expanded analysis which better explains our estimate of γ (and thus σ) for this compound. All numbers, figures and conclusions remain unaltered. The ruthenate compounds A2YRu1-xCuxO6 (with A = Ba or Sr; x = 0.05-0.15) are double-perovskites containing no cuprate planes and with ν = μ = 1 [1] (reference [82] in the paper). The determination of γ follows from equation (2.5b), wherein rule 1b introduces the factor 1/2. In the lower limit, one expects a minimum of ~2 charges per Cu dopant, which are shared between two charge reservoirs of each layer type (AO and 1/2 (YRu1-xCuxO4)), producing a net factor of unity. Thus, for Ba2YRu0.9Cu0.1O6 (with TC0 ~ 30-40 K), we estimate γ = (1/2)(1) = 1/2, yielding σ = 0.05 as stated by equation (2.5c) in the paper. While one may expect an average effective charge state for Ru near +5, and that of Cu to be between +2 and +3 (post anneal) [2], the lower-limit estimation provided, which places the corresponding data point in figure 2 to the left of the line, appears sufficient to include the ruthenates with the other high-TC compounds found to follow equation (2.6) so far. Owing to the uncertainty in the experimental values for TC0, as well as the Ru and Cu valence states, however, this compound was excluded in the data analyses presented. Future research will attempt a more accurate determination of the charge per doped Cu, and thus σ. We would also like to point out a typographical correction in the definition of the corresponding ruthenate type II reservoir in the last column of table 1, which should read 1/2 (YRu0.9Cu0.1O4). An unrelated item is found in the fourth line of section 2.3.3, where Tb(O0.80F0.20)FeAs should read Tb(O0.80-yF0.20)FeAs. Additionally, reference [132] is now known and has the form: [132] Harshman D R and Fiory A T 2011 J. Phys.: Condens. Matter 23 315702 References [1] Parkinson N G, Hatton P D, Howard J A K, Ritter C, Chien F Z and Wu M-K 2003 J. Mater. Chem. 13 1468 [2] Rao S M, Wu M-K, Ren H C, Chen C L, Guo J-H, Hsu F C, Chen S Y, Chen Y Y, Chang C L and Liu H L 2011 in preparation

  14. Assessment of the chemical status of the alluvial aquifer in the Aosta Plain: an example of the implementation of the Water Framework Directive in Italy

    NASA Astrophysics Data System (ADS)

    Rotiroti, Marco; Fumagalli, Letizia; Stefania, Gennaro A.; Frigerio, Maria C.; Simonetto, Fulvio; Capodaglio, Pietro; Bonomi, Tullia

    2015-04-01

    The Italian Legislative Decree 30/09 (D.Lgs. 30/09) implements the EU Water Framework Directive (WFD) providing some technical guidelines to assess the chemical status of groundwater bodies. This work presents the estimation of the chemical status of the shallow aquifer in the Aosta Plain (Aosta Valley Region, NW Alpine sector, Italy) on the basis of the D.Lgs. 30/09. The study area covers ~40 km2 along the Dora Baltea River basin. The Aosta Plain hosts an alluvial aquifer formed of lacustrine, glacial, fluvio-glacial and fan deposits of Pleistocene and Holocene ages. The unconfined aquifer features a depth of ~80 m in the western part of the plain and ~20 in the eastern part due to the intercalation of a silty lacustrine layer. The aquifer is mainly recharged by precipitation, surface water and ice and snow melt. Previous studies revealed that SO4, Fe, Mn, Ni, Cr(VI) and PCE represent potential threats for groundwater quality in the Aosta Plain. The chemical status was calculated using the data collected during the 2012 by the Regional Environmental Protection Agency of the Aosta Valley Region from its groundwater quality monitoring network that includes 38 points. Each point was sampled up to four times. Since the D.Lgs. 30/09 excludes Fe and Mn from the assessment of the groundwater chemical status, the present work deals with SO4, Ni, Cr(VI) and PCE. Threshold values (TVs) were estimated on the basis of natural background levels (NBLs) for SO4, Ni and Cr(VI) whereas, for PCE, the reference value (REF) reported by the D.Lgs. 30/09 (i.e., 1.1 µg/L) was used as TV. The NBLs were calculated using the two approaches suggested by the EU research project BRIDGE, that are the pre-selection and the component separation. The TVs were evaluated using the following criteria: (a) if NBL < REF, then TV = (REF+NBL)/2 and (b) if NBL ≥ REF, then TV = NBL. The average between the NBL resulted from the pre-selection and the component separation was used in the TV estimation. Finally, the chemical status was defined comparing the annual average concentration in each monitoring point to the TV: if more than 20% of sampling points exceeded the TV for at least one chemical parameter then the chemical status was defined as poor, otherwise the status was defined as good. The NBLs resulted of 10.1 µg/L, 1.8 µg/L and 115 mg/L from pre-selection and 9.4 µg/L, 2.3 µg/L and 148 mg/L from component separation for Ni, Cr(VI) and SO4, respectively. The TVs calculated are 15 µg/L, 3.6 µg/L and 191 mg/L for Ni, Cr(VI) and SO4, respectively. The percentages of sampling points exceeding the TV were 5.3, 23.7, 5.3 and 2.7 for Ni, Cr(VI), SO4 and PCE, therefore the groundwater chemical status in the Aosta Plain in 2012 resulted poor due to the high concentration of Cr(VI). This work underlines the necessity for remediation strategies to reduce the Cr(VI) pollution in the Aosta Plain in order to achieve the good chemical status as required by the WFD.

  15. Age related prostate-specific antigen reference range among men in south-East Caspian Sea.

    PubMed

    Mansourian, A R; Ghaemi, E O; Ahmadi, A R; Marjani, A; Moradi, A; Saifi, A

    2007-05-01

    The purpose of this study was to describe the distribution of serum prostate specific antigen (PSA) and to determine age-specific reference range in a population of Persian men. Venous blood samples were taken from 287 men, from Gorgan located in the North of Iran, South-East of Caspian Sea, aged 15 > or = 80 year. The serum PSA levels was measured using Enzyme-linked Immunosorbant-Assay (ELISA) technique and age-specific range for PSA level was determined. The serum prostate-specific antigen level for six age group of 15-40 years, 41-50 years, 51-60 years, 61-70 years, 71-80 years and >80 years were mainly in the range of 0-2.5 ng mL(-1), for 76.6%, 2.6-4 ng mL(-1) for 9.1% and as whole 85.7% of all men in this study had < or = 4 ng mL(-1), 8.7 and 5.6% all men of six age group had PSA level of 4.1-10 ng mL(-1) and >10 ng mL(-1), respectively. The findings of present study indicated that a large proportion (76.6%) men in this region have a lower PSA level of 0-2.5 ng mL(-1) and only 9.1% of men have PSA level of 2.6-4 ng mL(-1). It is therefore concluded that acceptable reference range of 0-4 ng mL(-1) for PSA level require further reassessment.

  16. Coronary artery bypass surgery with or without mitral valve annuloplasty in moderate functional ischemic mitral regurgitation: final results of the Randomized Ischemic Mitral Evaluation (RIME) trial.

    PubMed

    Chan, K M John; Punjabi, Prakash P; Flather, Marcus; Wage, Riccardo; Symmonds, Karen; Roussin, Isabelle; Rahman-Haley, Shelley; Pennell, Dudley J; Kilner, Philip J; Dreyfus, Gilles D; Pepper, John R

    2012-11-20

    The role of mitral valve repair (MVR) during coronary artery bypass grafting (CABG) in patients with moderate ischemic mitral regurgitation (MR) is uncertain. We conducted a randomized, controlled trial to determine whether repairing the mitral valve during CABG may improve functional capacity and left ventricular reverse remodeling compared with CABG alone. Seventy-three patients referred for CABG with moderate ischemic MR and an ejection fraction >30% were randomized to receive CABG plus MVR (34 patients) or CABG only (39 patients). The study was stopped early after review of interim data. At 1 year, there was a greater improvement in the primary end point of peak oxygen consumption in the CABG plus MVR group compared with the CABG group (3.3 mL/kg/min versus 0.8 mL/kg/min; P<0.001). There was also a greater improvement in the secondary end points in the CABG plus MVR group compared with the CABG group: left ventricular end-systolic volume index, MR volume, and plasma B-type natriuretic peptide reduction of 22.2 mL/m(2), 28.2 mL/beat, and 557.4 pg/mL, respectively versus 4.4 mL/m(2) (P=0.002), 9.2 mL/beat (P=0.001), and 394.7 pg/mL (P=0.003), respectively. Operation duration, blood transfusion, intubation duration, and hospital stay duration were greater in the CABG plus MVR group. Deaths at 30 days and 1 year were similar in both groups: 3% and 9%, respectively in the CABG plus MVR group, versus 3% (P=1.00) and 5% (P=0.66), respectively in the CABG group. Adding mitral annuloplasty to CABG in patients with moderate ischemic MR may improve functional capacity, left ventricular reverse remodeling, MR severity, and B-type natriuretic peptide levels, compared with CABG alone. The impact of these benefits on longer term clinical outcomes remains to be defined.

  17. Genetics Home Reference: L1 syndrome

    MedlinePlus

    ... X-linked hydrocephalus: evidence for closely related clinical entities of unknown molecular bases. Acta Neuropathol. 2013 Sep; ... F. Three cases with L1 syndrome and two novel mutations in the L1CAM gene. Eur J Pediatr. ...

  18. Certified ion implantation fluence by high accuracy RBS.

    PubMed

    Colaux, Julien L; Jeynes, Chris; Heasman, Keith C; Gwilliam, Russell M

    2015-05-07

    From measurements over the last two years we have demonstrated that the charge collection system based on Faraday cups can robustly give near-1% absolute implantation fluence accuracy for our electrostatically scanned 200 kV Danfysik ion implanter, using four-point-probe mapping with a demonstrated accuracy of 2%, and accurate Rutherford backscattering spectrometry (RBS) of test implants from our quality assurance programme. The RBS is traceable to the certified reference material IRMM-ERM-EG001/BAM-L001, and involves convenient calibrations both of the electronic gain of the spectrometry system (at about 0.1% accuracy) and of the RBS beam energy (at 0.06% accuracy). We demonstrate that accurate RBS is a definitive method to determine quantity of material. It is therefore useful for certifying high quality reference standards, and is also extensible to other kinds of samples such as thin self-supporting films of pure elements. The more powerful technique of Total-IBA may inherit the accuracy of RBS.

  19. Impact of calcium and TOC on biological acidification assessment in Norwegian rivers.

    PubMed

    Schneider, Susanne C

    2011-02-15

    Acidification continues to be a major impact in freshwaters of northern Europe, and the biotic response to chemical recovery from acidification is often not a straightforward process. The focus on biological recovery is relevant within the context of the EU Water Framework Directive, where a biological monitoring system is needed that detects differences in fauna and flora compared to undisturbed reference conditions. In order to verify true reference sites for biological analyses, expected river pH is modeled based on Ca and TOC, and 94% of variability in pH at reference sites is explained by Ca alone, while 98% is explained by a combination of Ca and TOC. Based on 59 samples from 28 reference sites, compared to 547 samples from 285 non-reference sites, the impact of calcium and total organic carbon (TOC) on benthic algae species composition, expressed as acidification index periphyton (AIP), is analyzed. Rivers with a high Ca concentration have a naturally higher AIP, and TOC affects reference AIP only at low Ca concentrations. Four biological river types are needed for assessment of river acidification in Norway based on benthic algae: very calcium-poor, humic rivers (Ca<1 mg/l and TOC>2 mg/l); very calcium-poor, clear rivers (Ca<1 mg/l and TOC<2 mg/l); calcium-poor rivers (Ca between 1 and 4 mg/l); moderately calcium rich rivers (Ca>4 mg/l). A biological assessment system for river acidification in Norway based on benthic algae is presented, following the demands of the Water Framework Directive. Copyright © 2010 Elsevier B.V. All rights reserved.

  20. 78 FR 69516 - DeltaPoint Capital IV, L.P.; License No. 02/02-0662; Notice Seeking Exemption Under the Small...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-11-19

    ... 107.730). DeltaPoint Capital IV, L.P. provided financing to BioMaxx, Inc., 1 Fishers Road, Suite 160...., an Associate of DeltaPoint Capital IV, L.P., owns more than ten percent of BioMaxx, Inc. Therefore...

  1. Construction of noninterpenetrating and interpenetrating Co(ii) networks with halogenated carboxylate modulated by auxiliary N-donor co-ligands: structural diversity, electrochemical and photocatalytic properties.

    PubMed

    Hao, Shao Yun; Hou, Suo Xia; Van Hecke, Kristof; Cui, Guang Hua

    2017-02-14

    Six Co(ii)-based coordination polymers (CPs) with characteristic frameworks and topologies-namely, [Co(L1)(DCTP)] n (1), [Co(L2)(DCTP)] n (2), [Co(L3)(DCTP)] n (3), {[Co 3 (L4) 3 (DCTP) 3 ·H 2 O]·H 2 O} n (4), [Co(L5) 1.5 (DCTP)] n (5) and [Co(L6)(DCTP)] n (6)-were successfully hydrothermally synthesized by employing the halogenated linear ligand 2,5-dichloroterephthalic acid (H 2 DCTP). The interpenetrated structures could be rationally modulated by auxiliary N-donor co-ligands containing 1,1'-(1,4-butanediyl)bis-1H-benzimidazole (L1), 1,4-bis(5,6-dimethylbenzimidazol-1-yl)-2-butylene (L2), 1,2-bis(2-methylbenzimidazol-1-ylmethyl)benzene (L3), 1,4-bis(2-methylbenzimidazol-1-ylmethyl)benzene (L4), 1,2-bis(5,6-dimethylbenzimidazol-1-ylmethyl)benzene (L5) and 1,4-bis(5,6-dimethylbenzimidazol-1-ylmethyl)benzene (L6). These diaphanous crystals were clearly characterized by elemental analysis, infrared (IR) spectra and X-ray powder diffraction (XRPD) as well as single-crystal X-ray diffraction analysis. With the aid of the flexible N-donor co-ligands, CP 1 occupies a non-interpenetrated 2D sheet with the point symbol {4 4 ·6 2 } sql net topology, CP 2 possesses a 3D hexagon-shaped network with the point symbol {6 6 } three-fold interpenetrated sqc6 topology, CP 3 exhibits a 2D layer with the point symbol {4 4 ·6 2 } sql net topology, CP 4 reveals an unusual 3D framework with the point symbol {4 2 ·6 3 ·8} three-fold interpenetrated sra topology, CP 5 has a 3D hexagon-shaped network with the point symbol {6 6 } two-fold interpenetrated sqc6 topology, while CP 6 displays a 3D hexagon-shaped network with the point symbol {6 6 } three-fold interpenetrated sqc6 topology. The diverse structures of CPs 1-6 illustrate that the substitute group and position of the methyl group of the bis(benzimidazole) derivatives play a significant role in the assembly of such interpenetrated frameworks. Moreover, luminescence properties and thermal behavior, as well as the electrochemical and photocatalytic properties of CPs 1-6 on the degradation of methylene blue, are also presented.

  2. On-line determination of pork color and intramuscular fat by computer vision

    NASA Astrophysics Data System (ADS)

    Liao, Yi-Tao; Fan, Yu-Xia; Wu, Xue-Qian; Xie, Li-juan; Cheng, Fang

    2010-04-01

    In this study, the application potential of computer vision in on-line determination of CIE L*a*b* and content of intramuscular fat (IMF) of pork was evaluated. Images of pork chop from 211 pig carcasses were captured while samples were on a conveyor belt at the speed of 0.25 m•s-1 to simulate the on-line environment. CIE L*a*b* and IMF content were measured with colorimeter and chemical extractor as reference. The KSW algorithm combined with region selection was employed in eliminating the surrounding fat of longissimus dorsi muscle (MLD). RGB values of the pork were counted and five methods were applied for transforming RGB values to CIE L*a*b* values. The region growing algorithm with multiple seed points was applied to mask out the IMF pixels within the intensity corrected images. The performances of the proposed algorithms were verified by comparing the measured reference values and the quality characteristics obtained by image processing. MLD region of six samples could not be identified using the KSW algorithm. Intensity nonuniformity of pork surface in the image can be eliminated efficiently, and IMF region of three corrected images failed to be extracted. Given considerable variety of color and complexity of the pork surface, CIE L*, a* and b* color of MLD could be predicted with correlation coefficients of 0.84, 0.54 and 0.47 respectively, and IMF content could be determined with a correlation coefficient more than 0.70. The study demonstrated that it is feasible to evaluate CIE L*a*b* values and IMF content on-line using computer vision.

  3. Transfer to the Collinear Libration Point L3 in the Sun-Earth+Moon System

    NASA Technical Reports Server (NTRS)

    Hou, Xi-yun; Tang, Jing-shi; Liu, Lin

    2007-01-01

    The collinear libration point L3 of the sun-earth+moon system is an ideal place for some space missions. Although there has been a great amount of work concerning the applications of the other two collinear libration points L1 and L2, little work has been done about the point L3. In this paper, the dynamics of the libration points was briefly introduced first. Then a way to transfer the spacecraft to the collinear libration point L3 via the invariant manifolds of the other two collinear libration points was proposed. Theoretical works under the model of circular restricted three-body problem were done. For the sun-earth+moon system, this model is a good approximation. The results obtained are useful when a transfer trajectory under the real solar system is designed.

  4. The effect of traditional African food mixtures on growth, pH and extracellular polysaccharide production by mutans streptococci in vitro.

    PubMed

    Toi, Cheryl Sam; Cleaton-Jones, Peter

    2006-04-01

    Four, traditional African food mixtures (maize plus milk and sugar, maize plus gravy, samp plus beans, brown bread plus margarine and peanut butter) were evaluated for their ability to sustain the growth of mutans streptococci in batch culture. A synthetic complex medium, brain heart infusion with 3% sucrose was used as an experimental control. Six NCTC laboratory reference strains and five clinical isolates collected from the plaque of children were investigated. The doubling time of bacterial strains was prolonged in maize plus gravy (2.5-6.0 h) and samp plus beans (1.3-9.9h), and the number of cell divisions was low, compared with bread plus margarine plus peanut butter (0.7-5.1h). The least amount of acid was produced in maize plus milk plus sugar (3.92+/-8.15 mmole/mL), and the average pH during the fermentation of maize plus milk plus sugar, maize plus gravy and samp plus beans did not drop below the critical point for enamel demineralisation, pH 5.7. Bacterial growth in samp plus beans produced a small quantity of lactic acid (0.46+/-1.10 mmole/mL) compared to bread plus margarine and peanut butter (2.64+/-3.30 mmole/mL) and BHI plus 3% sucrose (12.23+/-10.72 mmole/mL). Extracellular polysaccharide (ECP) produced was lowest in maize plus milk and sugar (0.22+/-0.33 mg/mL), compared with the remaining food mixtures (0.47-1.75 mg/mL). Statistical analysis showed that the influence of the mixed-foods on doubling time (F=3.01, P=0.03), pH (F=14.41, P<0.0001) and ECP (F=135.32, P<0.0001) was greater than the significant variance found between mutans streptococci strains. Results suggest that the level of mutans streptococci activity in samp plus beans, maize plus milk and sugar and maize plus gravy contributes little towards the formation of dental caries, and that significant differences exist between mutans streptococci laboratory reference and clinical strains in response to traditional African food mixtures.

  5. [Iodine intake in Portuguese school children].

    PubMed

    Limbert, Edward; Prazeres, Susana; São Pedro, Márcia; Madureira, Deolinda; Miranda, Ana; Ribeiro, Manuel; Carrilho, Francisco; Jácome de Castro, J; Lopes, Maria Santana; Cardoso, João; Carvalho, Andre; Oliveira, Maria João; Reguengo, Henrique; Borges, Fátima

    2012-01-01

    The aim of the present study was to evaluate iodine intake in portuguese school children in order to inform health authorities of eventual measures to be implemented. Iodine is the key element for thyroid hormone synthesis and its deficiency even mild, as found in other European countries, may have deleterious effects in pregnancy resulting in cognitive problems of offsprings. In Portugal there are no recent data on iodine intake in schoolchildren. 3680 children aged 6-12 years of both sexes, from 78 different schools were studied. Iodine intake was evaluated trough urine iodine (UI) determinations using a colorimetic method. The global median UI value was 105.5 µg/L; the percentage of children with UI <100 µg/L was 47.1%, corresponding to 41% of the studied schools. The percentage of values <50 µg/L was 11.8%. The male gender, the south region of the country and the distribution of milk in school were significantly linked with a higher iodine elimination. Our global results point to a borderline/ mildly insufficient iodine intake in the portuguese school population. However 47% of the children had UI under 100 µg /L. The comparison of our results with the available data from 30 years ago, point to a considerable improvement, due to silent prophylaxis. Male gender, geographical area and milk distribution influenced positively iodine intake.The importance of milk has been referred in numerous papers. The study of UI in the Portuguese school population points to a borderline iodine intake. However, in 47% of children iodine intake was inadequate. Compared with data from the eighties, a considerable increase in iodine elimination was found. Taking into account the potencial deleterious effects of inadequate iodine intake, a global prophylaxis with salt iodization has to be considered.

  6. Use of libration-point orbits for space observatories

    NASA Technical Reports Server (NTRS)

    Farquhar, Robert W.; Dunham, David W.

    1990-01-01

    The sun-earth libration points, L1 and L2, are located 1.5 million kilometers from the earth toward and away from the sun. Halo orbits about these points have significant advantages for space observatories in terms of viewing geometry, thermal and radiation environment, and delta-V expediture.

  7. Minimum Weight Design of Cylindrical Shell with Multiple Stiffener Sizes Under Buckling Constraint

    DTIC Science & Technology

    1977-10-01

    i.i.iiJ.i |..l.l.ll|l,«p»l|HII.I|lllB.I. SECTION I INTRODUCTION Since van der Neut (Reference 1) demonstrated the influtnce of eccentricity of...o:neral conclusions. ■■’ ■ ■■■—^-’—--^ ■ „J..,.....^ .... .a. a,-^,.,.,.. —..-.., mmmmmmmmm**** "■ REFERENCES 1. Van der Neut , A., "The General...Kicher, T. P., "Structural Synthesis of Integrally Stiffened Cylin- ders ", Journal of Spacecraft and Rockets, Vol. 5, Jan. 1968, pp. 62-67. Schmit

  8. Assessment of criteria used by veterinary practitioners to diagnose hypothyroidism in sighthounds and investigation of serum thyroid hormone concentrations in healthy Salukis.

    PubMed

    Shiel, Robert E; Sist, MaryDee; Nachreiner, Raymond F; Ehrlich, Claire P; Mooney, Carmel T

    2010-02-01

    To assess use of serum thyroid hormone concentrations by veterinarians to diagnose hypothyroidism in sighthounds and to evaluate serum thyroid hormone concentrations in healthy Salukis. Retrospective case series and cross-sectional study. 398 sighthounds of various breeds with a diagnosis of hypothyroidism and 283 healthy Salukis. Pretreatment thyroid hormone assay results from sighthounds subsequently classified as hypothyroid by practitioners were retrieved from a laboratory database. In healthy Salukis, serum concentrations of total thyroxine (T(4)), free T(4), total triiodothyronine (T(3)), free T(3), and thyroid-stimulating hormone (TSH) and antibodies against thyroglobulin and thyroid hormones were assayed. Records indicated hypothyroidism had been diagnosed in 303 (76.1%) sight-hounds on the basis of low serum thyroid hormone concentrations alone and in 30 (7.5%) others despite all thyroid hormone indices being within reference limits. Only 65 (16.3%) dogs had a high TSH concentration or positive thyroglobulin autoantibody result to support the diagnosis. In healthy Salukis, median (reference limits) serum concentrations of total T(4), free T(4), total T(3), free T(3), and TSH were 13.0 nmol/L (2.8 to 40.0 nmol/L), 12.0 pmol/L (2.0 to 30.3 pmol/L), 1.0 nmol/L (0.4 to 2.1 nmol/L), 4.0 pmol/L (1.6 to 7.7 pmol/L), and 0.18 ng/mL (0 to 0.86 ng/mL), respectively. Diagnosis of hypothyroidism by practitioners was most often made without adequate supportive laboratory evidence. Thyroid hormone values in healthy Salukis differed markedly from standard reference limits for some, but not all, thyroid hormone indices. Breed-specific reference limits should be used when interpreting thyroid hormone profiles of sighthounds.

  9. Impulsive time-free transfers between halo orbits

    NASA Astrophysics Data System (ADS)

    Hiday, L. A.; Howell, K. C.

    1992-08-01

    A methodology is developed to design optimal time-free impulsive transfers between three-dimensional halo orbits in the vicinity of the interior L1 libration point of the sun-earth/moon barycenter system. The transfer trajectories are optimal in the sense that the total characteristics velocity required to implement the transfer exhibits a local minimum. Criteria are established whereby the implementation of a coast in the initial orbit, a coast in the final orbit, or dual coasts accomplishes a reduction in fuel expenditure. The optimality of a reference two-impulse transfer can be determined by examining the slope at the endpoints of a plot of the magnitude of the primer vector on the reference trajectory. If the initial and final slopes of the primer magnitude are zero, the transfer trajectory is optimal; otherwise, the execution of coasts is warranted. The optimal time of flight on the time-free transfer, and consequently, the departure and arrival locations on the halo orbits are determined by the unconstrained minimization of a function of two variables using a multivariable search technique. Results indicate that the cost can be substantially diminished by the allowance for coasts in the initial and final libration-point orbits.

  10. Impulsive Time-Free Transfers Between Halo Orbits

    NASA Astrophysics Data System (ADS)

    Hiday-Johnston, L. A.; Howell, K. C.

    1996-12-01

    A methodology is developed to design optimal time-free impulsive transfers between three-dimensional halo orbits in the vicinity of the interior L 1 libration point of the Sun-Earth/Moon barycenter system. The transfer trajectories are optimal in the sense that the total characteristic velocity required to implement the transfer exhibits a local minimum. Criteria are established whereby the implementation of a coast in the initial orbit, a coast in the final orbit, or dual coasts accomplishes a reduction in fuel expenditure. The optimality of a reference two-impulse transfer can be determined by examining the slope at the endpoints of a plot of the magnitude of the primer vector on the reference trajectory. If the initial and final slopes of the primer magnitude are zero, the transfer trajectory is optimal; otherwise, the execution of coasts is warranted. The optimal time of flight on the time-free transfer, and consequently, the departure and arrival locations on the halo orbits are determined by the unconstrained minimization of a function of two variables using a multivariable search technique. Results indicate that the cost can be substantially diminished by the allowance for coasts in the initial and final libration-point orbits.

  11. Associations between disease awareness and health-related quality of life in a multi-ethnic Asian population.

    PubMed

    Venkataraman, Kavita; Khoo, ChinMeng; Wee, Hwee Lin; Tan, Chuen Seng; Ma, Stefan; Heng, Derrick; Lee, Jeannette; Tai, E Shyong; Thumboo, Julian

    2014-01-01

    Health related quality of life (HRQoL) is an important dimension of individuals' well-being, and especially in chronic diseases like diabetes and hypertension. The objective of this study was to evaluate the contributions of disease process, comorbidities, medication or awareness of the disease to HRQoL in diabetes mellitus, hypertension and dyslipidemia. This was a cross-sectional study of 3514 respondents from the general community in Singapore, assessed for HRQoL, disease and comorbid conditions through self-report, clinical and laboratory investigations. HRQoL was assessed using SF-36 health survey version 2. For each condition, participants were categorized as having 1) no disease, 2) undiagnosed, 3) diagnosed, not taking medication, and 4) diagnosed, taking medication. Analysis used one-way ANOVA and multiple linear regression. Diagnosed disease was associated with lower physical health component summary (PCS) scores across all three conditions. After adjustment for comorbidities, this association remained significant only for those not on medication in diabetes (-2.7±1.2 points, p = 0.03) and dyslipidemia (-1.3±0.4 points, p = 0.003). Diagnosed hypertension (no medication -2.6±0.9 points, p = 0.002; medication -1.4±0.5 points, p = 0.004) and dyslipidemia (no medication -0.9±0.4 points, p = 0.03; medication -1.9±0.5 points, p<0.001) were associated with lower mental health component summary (MCS) scores. Undiagnosed disease was associated with higher MCS in diabetes (2.4±1.0 points, p = 0.01) and dyslipidemia (0.8±0.4 points, p = 0.045), and PCS in hypertension (1.2±0.4 points, p = 0.004). Disease awareness was associated with lower HRQoL across the diseases studied, with PCS associations partially mediated by comorbidities. Equally importantly, undiagnosed disease was not associated with HRQoL deficits, which may partly explain why these individuals do not seek medical care.

  12. The generation and accumulation of interstitial atoms and vacancies in alloys with L1{sub 2} superstructure

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pantyukhova, Olga, E-mail: Pantyukhova@list.ru; Starenchenko, Vladimir, E-mail: star@tsuab.ru; Starenchenko, Svetlana, E-mail: sve-starenchenko@yandex.ru

    2016-01-15

    The dependences of the point defect concentration (interstitial atoms and vacancies) on the deformation degree were calculated for the L1{sub 2} alloys with the high and low antiphase boundaries (APB) energy in terms of the mathematical model of the work and thermal strengthening of the alloys with the L1{sub 2} structure; the concentration of the point defects generated and annihilated in the process of deformation was estimated. It was found that the main part of the point defects generating during plastic deformation annihilates, the residual density of the deformation point defects does not exceed 10{sup −5}.

  13. Pragmatic and evidence-based approach to paediatric cerebrospinal fluid reference limits for white cell count and concentrations of total protein and glucose.

    PubMed

    Josman, Nicky; Tee, Nancy W S; Maiwald, Matthias; Loo, Liat Hui; Ho, Clement K M

    2018-06-15

    It is often impractical for each laboratory to establish its own paediatric reference intervals. This is particularly true for specimen types collected using invasive procedures, for example, cerebrospinal fluid (CSF). Published CSF reference intervals for white cell count, and concentrations of total protein and glucose were reviewed by stakeholders in a paediatric hospital. Consensus reference intervals for the three CSF parameters were then subjected to verification using guidelines from the Clinical Laboratory Standards Institute and residual CSF specimens. Consensus paediatric reference intervals adapted from published studies with minor modifications were locally verified as follows. White cell count (x10 6 cells/L): 0-20 (<1 month); 0-10 (1-2 months); 0-5 (>2 months). Total protein (g/L): 0.3-1.2 (<1 month); 0.2-0.6 (1-3 months); 0.1-0.4 (>3 months). Glucose (mmol/L): 2.0-5.6 (<6 months); 2.4-4.3 (6 months or older). © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  14. Long Term Missions at the Sun-Earth Libration Point L1: ACE, SOHO, and WIND

    NASA Technical Reports Server (NTRS)

    Roberts, Craig E.

    2011-01-01

    Three heliophysics missions -- the Advanced Composition Explorer (ACE), Solar Heliospheric Observatory (SOHO), and the Global Geoscience WIND -- have been orbiting the Sun-Earth interior libration point L1 continuously since 1997, 1996, and 2004, respectively. ACE and WIND (both NASA missions) and SOHO (an ESA-NASA joint mission) are all operated from the NASA Goddard Space Flight Center (GSFC). While ACE and SOHO have been dedicated libration point orbiters since their launches, WIND has had also a remarkable 10-year career flying a deep-space, multiple lunar-flyby trajectory prior to 2004. That era featured 36 targeted lunar flybys with excursions to both L1 and L2 before its final insertion in L1 orbit. A figure depicts the orbits of the three spacecraft, showing projections of the orbits onto the orthographic planes of a solar rotating ecliptic frame of reference. The SOHO orbit is a quasi-periodic halo orbit, where the frequencies of the in-plane and out-of-plane motions are practically equal. Such an orbit is seen to repeat itself with a period of approximately 178 days. For ACE and WIND, the frequencies of the in-plane and out-of-plane motions are unequal, giving rise to the characteristic Lissajous motion. ACE's orbit is of moderately small amplitude, whereas WIND's orbit is a large-amplitude Lissajous of dimensions close to those of the SOHO halo orbit. As motion about the collinear points is inherently unstable, stationkeeping maneuvers are necessary to prevent orbital decay and eventual escape from the L1 region. Though the three spacecraft are dissimilar (SOHO is a 3-axis stabilized Sun pointer, WIND is a spin-stabilized ecliptic pole pointer, and ACE is also spin-stabilized with its spin axis maintained between 4 and 20 degrees of the Sun), the stationkeeping technique for the three is fundamentally the same. The technique consists of correcting the energy of the orbit via a delta-V directed parallel or anti-parallel to the Spacecraft-to-Sun line. SOHO achieves this using thrusters oriented in line with the solar direction. WIND achieves the delta-V via pulsing radial thrusters when aligned with the Sun. ACE uses axial thrusters to apply delta-V with a component that is 94% or more aligned with the ACE-Sun line. Sunward thrust adds energy to the orbit preventing decay back toward Earth. Thrust directed anti-Sunward takes energy out of the L1 orbit, thereby preventing escape from the Earth-Moon system into independent heliocentric orbit. Libration point orbit stationkeeping delta-V costs grow exponentially with time elapsed from the last maneuver performed. The doubling time constant is approximately 16 days. For the sake of fuel conservation, and for limiting the absolute magnitude of propulsion performance errors, stationkeeping maneuvers should be performed before the delta-V grows too large; for our purposes 'too large' is considered to be greater than 0.5 m/sec. In practice, the typical interval between burns for this trio is about three months, and the typical delta-V is much smaller than 0.5 m/sec. Typical annual stationkeeping costs have been around 1.0 m/sec for ACE and WIND, and much less than that for SOHO. All three spacecraft have ample fuel remaining; barring contingencies all three could, in principle, be maintained at L1 for decades to come. This paper will review the L1 orbits and the mission history of ACE, WIND, and SOHO, and describe the stationkeeping techniques and orbit maneuver experience. The Lissajous phase control that was practiced for ACE during the period from 1999 to 2001 will also be briefly discussed. The final section will consider the future of these ongoing missions.

  15. Definite Discourse--New Reference in L1 and L2: A Study of Bridging in Mandarin, Korean, and English

    ERIC Educational Resources Information Center

    Crosthwaite, Peter Robert

    2014-01-01

    Definite expressions may be used to introduce a referent into discourse when their familiarity between speaker and listener can be inferred, a strategy known as bridging. However, for a number of reasons, bridging may be difficult to acquire compared to the acquisition of indefinite introductions for noninferable referent types, with the native…

  16. Abnormalities of the axial and proximal appendicular skeleton in adults with Laron syndrome (growth hormone insensitivity).

    PubMed

    Kornreich, L; Konen, O; Schwarz, M; Siegel, Y; Horev, G; Hershkovitz, I; Laron, Z

    2008-02-01

    To investigate abnormalities in the skeleton (with the exclusion of the skull, cervical spine, hands and feet) in patients with Laron syndrome, who have an inborn growth hormone resistance and congenital insulin-like growth factor-1 (IGF-1) deficiency. The study group was composed of 15 untreated patients with Laron syndrome (seven male and eight female) aged 21-68 years. Plain films of the axial and appendicular skeleton were evaluated retrospectively for abnormalities in structure and shape. The cortical width of the long bones was evaluated qualitatively and quantitatively (in the upper humerus and mid-femur), and the cortical index was calculated and compared with published references. Measurements were taken of the mid-anteroposterior and cranio-caudal diameters of the vertebral body and spinous process at L3, the interpedicular distance at L1 and L5, and the sacral slope. Thoracic and lumbar osteophytes were graded on a 5-point scale. Values were compared with a control group of 20 healthy persons matched for age. The skeleton appeared small in all patients. No signs of osteopenia were visible. The cortex of the long bones appeared thick in the upper limbs in 11 patients and in the lower limbs in four. Compared with the reference values, the cortical width was thicker than average in the humerus and thinner in the femur. The vertebral diameters at L3 and the interpedicular distances at L1 and L5 were significantly smaller in the patients than in the control subjects (P<0.001); however, at L5 the canal was wider, relative to the vertebral body. The study group had a higher rate of anterior osteophytes in the lumbar spine than the controls had, and their osteophytes were also significantly larger. In the six patients for whom radiographs of the upper extremity in its entirety were available on one film, the ulna appeared to be rotated. In one 22-year-old man, multiple epiphyses were still open. Congenital IGF-1 deficiency leads to skeletal abnormalities characterized by small bones, narrow spinal canal, and delayed bone age. The limitation in elbow distensibility common to patients with Laron syndrome may be related to a marked retroversion of the humeral head.

  17. Rates and patterns of great ape retrotransposition

    PubMed Central

    Hormozdiari, Fereydoun; Konkel, Miriam K.; Prado-Martinez, Javier; Chiatante, Giorgia; Herraez, Irene Hernando; Walker, Jerilyn A.; Nelson, Benjamin; Alkan, Can; Sudmant, Peter H.; Huddleston, John; Catacchio, Claudia R.; Ko, Arthur; Malig, Maika; Baker, Carl; Genome Project, Great Ape; Marques-Bonet, Tomas; Ventura, Mario; Batzer, Mark A.; Eichler, Evan E.

    2013-01-01

    We analyzed 83 fully sequenced great ape genomes for mobile element insertions, predicting a total of 49,452 fixed and polymorphic Alu and long interspersed element 1 (L1) insertions not present in the human reference assembly and assigning each retrotransposition event to a different time point during great ape evolution. We used these homoplasy-free markers to construct a mobile element insertions-based phylogeny of humans and great apes and demonstrate their differential power to discern ape subspecies and populations. Within this context, we find a good correlation between L1 diversity and single-nucleotide polymorphism heterozygosity (r2 = 0.65) in contrast to Alu repeats, which show little correlation (r2 = 0.07). We estimate that the “rate” of Alu retrotransposition has differed by a factor of 15-fold in these lineages. Humans, chimpanzees, and bonobos show the highest rates of Alu accumulation—the latter two since divergence 1.5 Mya. The L1 insertion rate, in contrast, has remained relatively constant, with rates differing by less than a factor of three. We conclude that Alu retrotransposition has been the most variable form of genetic variation during recent human–great ape evolution, with increases and decreases occurring over very short periods of evolutionary time. PMID:23884656

  18. Geoscience laser altimeter system-stellar reference system

    NASA Astrophysics Data System (ADS)

    Millar, Pamela S.; Sirota, J. Marcos

    1998-01-01

    GLAS is an EOS space-based laser altimeter being developed to profile the height of the Earth's ice sheets with ~15 cm single shot accuracy from space under NASA's Mission to Planet Earth (MTPE). The primary science goal of GLAS is to determine if the ice sheets are increasing or diminishing for climate change modeling. This is achieved by measuring the ice sheet heights over Greenland and Antarctica to 1.5 cm/yr over 100 km×100 km areas by crossover analysis (Zwally 1994). This measurement performance requires the instrument to determine the pointing of the laser beam to ~5 urad (1 arcsecond), 1-sigma, with respect to the inertial reference frame. The GLAS design incorporates a stellar reference system (SRS) to relate the laser beam pointing angle to the star field with this accuracy. This is the first time a spaceborne laser altimeter is measuring pointing to such high accuracy. The design for the stellar reference system combines an attitude determination system (ADS) with a laser reference system (LRS) to meet this requirement. The SRS approach and expected performance are described in this paper.

  19. 50 CFR Appendix B to Part 622 - Gulf Areas

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... Restricted Area Point No. and reference location 1 North lat. West long. 1Seaward limit of Florida's waters...—Offshore 26°26.0′ 82°59.0′ 4West of Egmont Key 27°30.0′ 83°21.5′ 5Off Anclote Keys—Offshore 28°10.0′ 83°45... Point No. and reference location 1 North lat. West long. 1Seaward limit of Florida's waters northeast of...

  20. 50 CFR Appendix B to Part 622 - Gulf Areas

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... Restricted Area Point No. and reference location 1 North lat. West long. 1Seaward limit of Florida's waters...—Offshore 26°26.0′ 82°59.0′ 4West of Egmont Key 27°30.0′ 83°21.5′ 5Off Anclote Keys—Offshore 28°10.0′ 83°45... Point No. and reference location 1 North lat. West long. 1Seaward limit of Florida's waters northeast of...

  1. 50 CFR Appendix B to Part 622 - Gulf Areas

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... Restricted Area Point No. and reference location 1 North lat. West long. 1Seaward limit of Florida's waters...—Offshore 26°26.0′ 82°59.0′ 4West of Egmont Key 27°30.0′ 83°21.5′ 5Off Anclote Keys—Offshore 28°10.0′ 83°45... Point No. and reference location 1 North lat. West long. 1Seaward limit of Florida's waters northeast of...

  2. Ammonia concentrations in canine whole blood, EDTA-anticoagulated whole blood, and plasma measured by use of a point-of-care ammonia meter.

    PubMed

    Odunayo, Adesola; Tobias, Karen M; Okafor, Chika C; Flatland, Bente

    2017-11-01

    OBJECTIVE To investigate the use of canine whole blood (WB) for measurement of ammonia concentration by use of a point-of-care ammonia meter and to compare results of measuring ammonia concentrations in WB, EDTA-anticoagulated WB, and plasma. ANIMALS 40 client-owned dogs. PROCEDURES A blood sample (2 mL) was obtained from each dog. One drop of WB was immediately applied to a test strip for evaluation with an ammonia meter. The remainder of the blood sample was placed in an EDTA-containing tube, and 1 drop of EDTA-anticoagulated WB was applied to a test strip. The remaining EDTA-anticoagulated WB sample was centrifuged, and the plasma was harvested and placed on ice. One drop of plasma was applied to a test strip; the remainder of the plasma sample was transported on ice and used for ammonia measurement with a reference laboratory instrument. All samples were tested within 1 hour after sample collection. Results were evaluated to detect significant differences in ammonia concentration. RESULTS Ammonia concentrations did not differ significantly between WB and EDTA-anticoagulated WB and between plasma samples measured with the meter and reference laboratory instrument. However, median ammonia concentration was significantly higher in plasma than in WB or EDTA-anti-coagulated WB. CONCLUSIONS AND CLINICAL RELEVANCE Anticoagulant-free WB was a valid sample for measurement by use of the ammonia meter. Plasma samples had higher ammonia concentrations than did WB samples. Results for each sample type should be interpreted by use of specimen- and method-specific reference intervals.

  3. Planning hospital boards for the future. Interview by Donald E. L. Johnson.

    PubMed

    Wedel, P G

    1990-08-01

    Lancaster General Hospital, a 553-bed institution in Lancaster County, Pennsylvania, was founded in 1893. Hospital services include trauma, cancer, and neo-natal centers and open-heart and neurosurgery specialties. In the following interview with Health Care Strategic Management's publisher, Donald E.L. Johnson, Paul G. Wedel, President and Chief Executive Officer discusses the future challenges confronting hospital foundation boards. Lancaster General's 18-member planning board which charts the course for the 28,000 employee and 550 medical staff institution serves as a familiar point of reference.

  4. Serum fructosamine concentrations in 59 dogs naturally Infected with Angiostrongylus vasorum.

    PubMed

    Willesen, J L; Jensen, A L; Kristensen, A T; Kjelgaard-Hansen, M; Jessen, R; Koch, J

    2006-06-01

    Retrospectively, 89 cases of dogs infected with Angiostrongylus vasorum were examined. Fifty-nine of these 89 dogs fulfilled the criteria of not being dually infected with Crenosoma vulpis as well as having a full biochemistry profile including serum fructosamine available. The mean serum fructosamine value of the 59 dogs was 236 micromol/l (reference value 258-348 micromol/l) and significantly lower than the serum fructosamine level of 314 micromol/l in a control group of 42 clinically healthy dogs. Eleven dogs were available for follow up after successful treatment of angiostrongylosis. In this group, the serum fructosamine value rose from a mean of 244 micromol/l to a mean of 320 micromol/l following treatment. Serum glucose, albumin and protein were all within the respective reference ranges at all sampling points. The results indicate that serum fructosamine could be affected by infection with A. vasorum. Furthermore, this change cannot be explained by measurable changes in the level of glucose, albumin or protein. The clinical impact of this study is that a low fructosamine value may indicate infection with A. vasorum thereby suggesting a Baermann test to be performed.

  5. Characterizing the Lateral Border of the Frontalis for Safe and Effective Injection of Botulinum Toxin.

    PubMed

    Choi, You-Jin; Won, Sung-Yoon; Lee, Jae-Gi; Hu, Kyung-Seok; Kim, Sung-Taek; Tansatit, Tanvaa; Kim, Hee-Jin

    2016-03-01

    The forehead is a common site for injection of botulinum neurotoxin type A (BoNT-A) to treat hyperactive facial muscles. Unexpected side effects of BoNT-A injection may occur because the anatomy of the forehead musculature is not fully characterized. The authors described the lateral border of the frontalis in terms of facial landmarks and reference lines to determine the safest and most effective forehead injection sites for BoNT-A. The hemifaces of 49 embalmed adult Korean cadavers were dissected in a morphometric analysis of the frontalis. L2 was defined in terms of FT (the most protruding point of the frontotemporal region), L0 (the line connecting the infraorbital margin with the tragus), and L1 (the line parallel to L0 and passing through FT) such that L2 was positioned 45° from L1 and passed through FT. The distance from FT to the superior margin of the orbicularis oculi was 12.3 ± 3.3 mm. The frontalis extended more than 5 cm along L2 in 49 of 49 cases (100%), more than 6 cm in 47 cases (95.9%), more than 7 cm in 34 cases (69.4%), more than 8 cm in 11 cases (22.4%), and more than 9 cm in 3 cases (6.1%). The lateral border of the frontalis ran parallel to and within 1 cm of the medial side of L2. Surface anatomy mapping can assist with predicting the lateral border of the frontalis to minimize the side effects and maximize the efficiency of BoNT-A injections into the forehead. © 2015 The American Society for Aesthetic Plastic Surgery, Inc. Reprints and permission: journals.permissions@oup.com.

  6. Characterizing the Lateral Border of the Frontalis for Safe and Effective Injection of Botulinum Toxin

    PubMed Central

    Choi, You-Jin; Won, Sung-Yoon; Lee, Jae-Gi; Hu, Kyung-Seok; Kim, Sung-Taek; Tansatit, Tanvaa; Kim, Hee-Jin

    2016-01-01

    Background The forehead is a common site for injection of botulinum neurotoxin type A (BoNT-A) to treat hyperactive facial muscles. Unexpected side effects of BoNT-A injection may occur because the anatomy of the forehead musculature is not fully characterized. Objectives The authors described the lateral border of the frontalis in terms of facial landmarks and reference lines to determine the safest and most effective forehead injection sites for BoNT-A. Methods The hemifaces of 49 embalmed adult Korean cadavers were dissected in a morphometric analysis of the frontalis. L2 was defined in terms of FT (the most protruding point of the frontotemporal region), L0 (the line connecting the infraorbital margin with the tragus), and L1 (the line parallel to L0 and passing through FT) such that L2 was positioned 45° from L1 and passed through FT. Results The distance from FT to the superior margin of the orbicularis oculi was 12.3 ± 3.3 mm. The frontalis extended more than 5 cm along L2 in 49 of 49 cases (100%), more than 6 cm in 47 cases (95.9%), more than 7 cm in 34 cases (69.4%), more than 8 cm in 11 cases (22.4%), and more than 9 cm in 3 cases (6.1%). The lateral border of the frontalis ran parallel to and within 1 cm of the medial side of L2. Conclusions Surface anatomy mapping can assist with predicting the lateral border of the frontalis to minimize the side effects and maximize the efficiency of BoNT-A injections into the forehead. PMID:26507959

  7. Multicomponent blood lipid analysis by means of near infrared spectroscopy, in geese.

    PubMed

    Bazar, George; Eles, Viktoria; Kovacs, Zoltan; Romvari, Robert; Szabo, Andras

    2016-08-01

    This study provides accurate near infrared (NIR) spectroscopic models on some laboratory determined clinicochemical parameters (i.e. total lipid (5.57±1.95 g/l), triglyceride (2.59±1.36 mmol/l), total cholesterol (3.81±0.68 mmol/l), high density lipoprotein (HDL) cholesterol (2.45±0.58 mmol/l)) of blood serum samples of fattened geese. To increase the performance of multivariate chemometrics, samples significantly deviating from the regression models implying laboratory error were excluded from the final calibration datasets. Reference data of excluded samples having outlier spectra in principal component analysis were not marked as false. Samples deviating from the regression models but having non outlier spectra in PCA were identified as having false reference constituent values. Based on the NIR selection methods, 5% of the reference measurement data were rated as doubtful. The achieved models reached R(2) of 0.864, 0.966, 0.850, 0.793, and RMSE of 0.639 g/l, 0.232 mmol/l, 0.210 mmol/l, 0.241 mmol/l for total lipid, triglyceride, total cholesterol and HDL cholesterol, respectively, during independent validation. Classical analytical techniques focus on single constituents and often require chemicals, time-consuming measurements, and experienced technicians. NIR technique provides a quick, cost effective, non-hazardous alternative method for analysis of several constituents based on one single spectrum of each sample, and it also offers the possibility for looking at the laboratory reference data critically. Evaluation of reference data to identify and exclude falsely analyzed samples can provide warning feedback to the reference laboratory, especially in the case of analyses where laboratory methods are not perfectly suited to the subjected material and there is an increased chance of laboratory error. Copyright © 2016 Elsevier B.V. All rights reserved.

  8. Assessment of antidiabetic activity and acute toxicity of leaf extracts from Physalis peruviana L. in guinea-pig

    PubMed Central

    Kasali, Félicien Mushagalusa; Kadima, Justin Ntokamunda; Mpiana, Pius Tshimankinda; Ngbolua, Koto-te-Nyiwa; Tshibangu, Damien Sha-Tshibey

    2013-01-01

    Objective To verify the antidiabetic activity of leaf extracts from Physalis peruviana L. popularly used in the Eastern part of the Democratic Republic of the Congo and to point out the possible toxicity. Method Aqueous decoctions prepared from dried leaves powder were administrated to guinea pigs at the dose range of 100 mg/kg to 3.2 g/kg of body weight. The hypoglycemic activity was evaluated by glucose tolerance test, loading animals with glucose 4 g/kg and measuring blood glucose concentrations at various times. The effect was compared to the control and glibenclamide as antidiabetic reference drug. Acute toxicity was evaluated by recording mortality rate, changes on blood biomarkers and damage caused to vital organs. Results At a dose of 100 mg/kg, the aqueous extract induced a significant reduction of peak concentration at 30 min after glucose loading as compared with control or reference (P<0.05). At doses greater than 400 mg, some alterations on blood, kidney and liver markers were observed. Upper 800 mg/kg, mortality was observed with LD50 estimated at about 1 280 mg/kg. At the autopsy, vital organs were in haemorrhage and swelling state. Conclusion The crude aqueous extracts from the leaves of Physalis peruviana L. present hypoglycemic activity in animal model, but at high doses the plant may cause severe intoxication.

  9. [MPLW515L point mutation in patients with myeloproliferative disease].

    PubMed

    Xia, Jun; Xu, Wei; Zhang, Su-Jiang; Fan, Lei; Qiao, Chun; Li, Jian-Yong

    2008-12-01

    In order to investigate the frequency of MPLW515L and JAK2V617F point mutations of the patients with myeloproliferative disease (MPD) in Nanjing area, MPLW515L and JAK2V617F point mutations were simultaneously detected by alleles specific polymerase chain reaction (AS-PCR) and sequencing in 190 MPD patients. The results showed that MPLW515L point mutation was detected in 1 out of 102 essential thrombocythemia (ET) patients (1.0%) and was not detected in 32 polycythemia vera (PV) patients, 13 idiopathic myelofibrosis (IMF) patients, 43 chronic myelogenous leukemia (CML) patients. JAK2V617F point mutation was detected in 20 out of 32 PV patients (62.5%), 43 out of 102 ET patients (42.2%), 5 out of 13 IMF patients (38.5%), and was not detected in 43 CML patients. It is concluded that MPLW515L point mutation exists in ET patient, but is not found in PV, IMF and CML. JAK2V617F point mutation exists in PV, ET and IMF, but not in CML.

  10. Use of LARS system for the quantitative determination of smoke plume lateral diffusion coefficients from ERTS images of Virginia

    NASA Technical Reports Server (NTRS)

    Blais, R. N.; Copeland, G. E.; Lerner, T. H.

    1975-01-01

    A technique for measuring smoke plume of large industrial sources observed by satellite using LARSYS is proposed. A Gaussian plume model is described, integrated in the vertical, and inverted to yield a form for the lateral diffusion coefficient, Ky. Given u, wind speed; y sub l, the horizontal distance of a line of constant brightness from the plume symmetry axis a distance x sub l, downstream from reference point at x=x sub 2, y=0, then K sub y = u ((y sub 1) to the 2nd power)/2 x sub 1 1n (x sub 2/x sub 1). The technique is applied to a plume from a power plant at Chester, Virginia, imaged August 31, 1973 by LANDSAT I. The plume bends slightly to the left 4.3 km from the source and estimates yield Ky of 28 sq m/sec near the source, and 19 sq m/sec beyond the bend. Maximum ground concentrations are estimated between 32 and 64 ug/cu m. Existing meteorological data would not explain such concentrations.

  11. Monitoring dehydroepiandrosterone (DHEA) in the urine of Thoroughbred geldings for doping control purposes.

    PubMed

    Viljanto, Marjaana; Hincks, Pamela; Hillyer, Lynn; Cawley, Adam; Suann, Craig; Noble, Glenys; Walker, Christopher J; Parkin, Mark C; Kicman, Andrew T; Scarth, James

    2018-05-24

    The use of testosterone and its pro-drugs, such as DHEA, is currently regulated in horseracing by the application of international testosterone thresholds. However, additional steroidomic approaches, such as steroid ratios, to distinguish overall adrenal stimulation from drug administrations and an equine biological passport for longitudinal steroid profiling of individual animals could be advantageous in equine doping testing. Thus, DHEA concentrations and related ratios (testosterone (T) to DHEA and DHEA to epitestosterone (E)) were assessed in the reference population by quantitative analysis of 200 post-race gelding urine samples using liquid chromatography tandem mass spectrometry. DHEA concentrations ranged between 0.9 and 136.6 ng/mL (mean 12.8 ng/mL), T:DHEA ratios between 0.06 and 1.85 (mean 0.43) and DHEA:E ratios between 0.21 and 13.56 (mean 2.20). Based on the reference population statistical upper limits of 5.4 for T:DHEA ratio and 48.1 for DHEA:E ratio are proposed with a risk of 1 in 10,000 for a normal outlier exceeding the value. Analysis of post-administration urine samples collected following administrations of DHEA, EquiBolic&® (a mix of DHEA and pregnenolone) and testosterone propionate to geldings showed that the upper limit for T:DHEA ratio was exceeded following testosterone propionate administration and DHEA:E ratio following DHEA administrations and thus these ratios could be used as additional biomarkers when determining the cause of an atypical testosterone concentration. Additionally, DHEA concentrations and ratios can be used as a starting point to establish reference ranges for an equine biological passport. This article is protected by copyright. All rights reserved.

  12. Screening Bilingual Preschoolers for Language Difficulties: Utility of Teacher and Parent Reports

    ERIC Educational Resources Information Center

    Pua, Emmanuel Peng Kiat; Lee, Mary Lay Choo; Rickard Liow, Susan J.

    2017-01-01

    Purpose: The utility of parent and teacher reports for screening 3 types of bilingual preschoolers (English-first language [L1]/Mandarin-second language[L2], Mandarin-L1/English-L2, or Malay-L1/English-L2) for language difficulty was investigated in Singapore with reference to measures of reliability, validity, sensitivity, and specificity in an…

  13. Automatic identification of the reference system based on the fourth ventricular landmarks in T1-weighted MR images.

    PubMed

    Fu, Yili; Gao, Wenpeng; Chen, Xiaoguang; Zhu, Minwei; Shen, Weigao; Wang, Shuguo

    2010-01-01

    The reference system based on the fourth ventricular landmarks (including the fastigial point and ventricular floor plane) is used in medical image analysis of the brain stem. The objective of this study was to develop a rapid, robust, and accurate method for the automatic identification of this reference system on T1-weighted magnetic resonance images. The fully automated method developed in this study consisted of four stages: preprocessing of the data set, expectation-maximization algorithm-based extraction of the fourth ventricle in the region of interest, a coarse-to-fine strategy for identifying the fastigial point, and localization of the base point. The method was evaluated on 27 Brain Web data sets qualitatively and 18 Internet Brain Segmentation Repository data sets and 30 clinical scans quantitatively. The results of qualitative evaluation indicated that the method was robust to rotation, landmark variation, noise, and inhomogeneity. The results of quantitative evaluation indicated that the method was able to identify the reference system with an accuracy of 0.7 +/- 0.2 mm for the fastigial point and 1.1 +/- 0.3 mm for the base point. It took <6 seconds for the method to identify the related landmarks on a personal computer with an Intel Core 2 6300 processor and 2 GB of random-access memory. The proposed method for the automatic identification of the reference system based on the fourth ventricular landmarks was shown to be rapid, robust, and accurate. The method has potentially utility in image registration and computer-aided surgery.

  14. Analytical validation and establishment of reference intervals for a 'high-sensitivity' cardiac troponin-T assay in horses.

    PubMed

    Shields, E; Seiden-Long, I; Massie, S; Passante, S; Leguillette, R

    2016-06-13

    Cardiac troponin-I assays have been validated in horses.'High-sensitivity' cardiac troponin assays are now the standard in human cardiology. Appropriately validate the'high-sensitivity' cardiac Troponin-T (hscTnT) assay for clinical use in horses, establish reference intervals, determine the biological variation, and demonstrate assay utility in selected clinical cases. Analytical validation of the Roche hscTnT assay included within- and between-run precision, linear dose response, limit of quantitation (LoQ), stability, and comparison with cTn-I (iSTAT). Reference intervals and biological variation were determined using adult, healthy, Non-Competition Horses (N = 125) and Racing-Thoroughbreds (N = 178). HscTnT levels were measured in two horses with cardiac pathology. The hscTnT demonstrates acceptable within-run (L1 = 6.5 ng/L, CV 14.9 %, L2 = 10.1 ng/L, CV 8.7 %, L3 = 15.3 ng/L, CV 5.4 %) and between-run precision (L1 = 12.2 ng/L, CV 8.4 %, L2 = 57.0 ng/L, CV 8.4 %, L3 = 256.0 ng/L, CV 9.0 %). The assay was linear from 3 to 391 ng/L. The LoQ was validated at 3 ng/L. Samples demonstrated insignificant decay over freeze-thaw cycle. Comparison with cTnI assay showed excellent correlation (range: 8.0-3535.0 ng/L, R(2) = 0.9996). Reference intervals: The upper 95(th) and 99(th) percentile of the hscTnT population distribution were 6.8 and 16.2 ng/L in Non-Competition Horses, and 14.0 and 23.2 ng/L in Racing-Thoroughbreds. Between-breed, diurnal effect, and between-day variation was below LoQ. Two clinical cases with presumed cardiac pathology had hscTnT levels of 220.9 ng/L and 5723.0 ng/L. This benchmark study is the first to comply with CLSI guidelines, thus further establishing the performance characteristics of the hscTnT assay, and reference intervals in healthy horses. Two clinical cases demonstrated further the clinical utility of the assay.

  15. A disposable chronocoulometric sensor for heavy metal ions using a diaminoterthiophene-modified electrode doped with graphene oxide.

    PubMed

    Choi, Seung-Min; Kim, Dong-Min; Jung, Ok-Sang; Shim, Yoon-Bo

    2015-09-10

    The rapid simultaneous determination of cadmium, lead, copper, and mercury ions is performed by employing a disposable sensor modified with graphene oxide (GO) doped diaminoterthiophene (GO/DTT) for chronocoulometry (CC). The performances of CC with and without pre-deposition in two opposite potential step directions were compared with square wave anodic stripping voltammetry (SWASV) under various conditions. The surface of the GO/DTT modified screen print carbon electrode (SPCE) was characterized by SEM, EDXS, and electrochemical impedance spectroscopy (EIS). Experimental variables that affect the response signal such as the pH, deposition time, type of supporting electrolyte, concentration of DTT, content ratio of GO to DTT, and Nafion content were optimized. Interference effects due to other heavy metal ions were also investigated. The dynamic ranges of SWASV and CC were between 1 ng mL(-1) and 2.5 μg mL(-1) and between 1 ng mL(-1) and 10 μg mL(-1), respectively. The detection limits for Cd(2+), Pb(2+), Cu(2+), Hg(2+) ions were 1.9 ± 0.4 ng mL(-1), 2.8 ± 0.6 ng mL(-1), 0.8 ± 0.2 ng mL(-1), and 2.6 ± 0.9 ng mL(-1) for the CC stripping method; 2.6 ± 0.2 ng mL(-1), 0.5 ± 0.1 ng mL(-1), 1.8 ± 0.3 ng mL(-1), and 3.2 ± 0.3 ng mL(-1) for the CC deposition method; and 7.1 ± 0.9, 1.9 ± 0.3, 0.4 ± 0.1, and 0.7 ± 0.1 ng mL(-1) for SWASV. The reliability of the method for point-of-analysis was evaluated by analyzing a urine standard reference material and some water samples. Copyright © 2015 Elsevier B.V. All rights reserved.

  16. [Pharmacokinetics of scopolamine hydrobromide oral disintegrative microencapsule tablets in Beagle dogs determined with LC-MS/MS].

    PubMed

    Xia, Tian; Liu, De-Ding; Shi, Li-Fu; Hu, Jin-Hong

    2011-08-01

    The study aims to elucidate the characteristics of pharmacokinetics of scopolamine hydrobromide oral disintegrative microencapsule tablets in healthy Beagle dogs. Chromatographic separation was performed on a C18 column (100 mm x 3.0 mm, 3.5 microm) with methanol - 2 mmol x L(-1) ammonium formate (25 : 75) as the mobile phase. A trip-quadrupole tandem mass spectrum with the electrospray ionization (ESI) source was applied and positive ion multiple reaction monitoring mode was operated. Six Beagle dogs were randomly devided into two groups. They received oral single dose of scopolamine hydrobromide oral disintegrative microencapsule tablets 0.6 mg (test tablet) or scopolamine hydrobromide normal tablets (reference tablet). Plasma samples were collected at designed time. Plasma concentration of scopolamine hydrobromide was determined by LC-MS/MS and pharmacokinetic parameters were calculated. The pharmacokinetic parameters of test tablet vs reference tablet were as follows: C(max): (8.16 +/- 0.67) ng x mL(-1) vs (3.54 +/- 0.64) ng x mL(-1); t1/2: (2.83 +/- 0.45) h vs (3.85 +/- 0.82) h; t(max): (1.25 +/- 0.27) h vs (0.42 +/- 0.09) h; AUC(0-12h): (25.06 +/- 3.75) h x ng x mL(-1) vs (9.59 +/- 1.02) h x ng x mL(-1); AUC(0-infinity): (26.30 +/- 3.92) h x ng x mL(-1) vs (10.80 +/- 1.45) h x ng x mL(-1); MRT(0-12h): (3.38 +/- 0.34) h vs (3.86 +/- 0.26) h; MRT(0-infinity): (3.98 +/- 0.63) h vs (5.37 +/- 1.00) h. The absorption rate and AUC of test tablet is different from that of reference tablet. The bioavailability of test tablet is better than those of reference tablet.

  17. A new scoring method for evaluating the performance of earthquake forecasts and predictions

    NASA Astrophysics Data System (ADS)

    Zhuang, J.

    2009-12-01

    This study presents a new method, namely the gambling score, for scoring the performance of earthquake forecasts or predictions. Unlike most other scoring procedures that require a regular scheme of forecast and treat each earthquake equally, regardless their magnitude, this new scoring method compensates the risk that the forecaster has taken. A fair scoring scheme should reward the success in a way that is compatible with the risk taken. Suppose that we have the reference model, usually the Poisson model for usual cases or Omori-Utsu formula for the case of forecasting aftershocks, which gives probability p0 that at least 1 event occurs in a given space-time-magnitude window. The forecaster, similar to a gambler, who starts with a certain number of reputation points, bets 1 reputation point on ``Yes'' or ``No'' according to his forecast, or bets nothing if he performs a NA-prediction. If the forecaster bets 1 reputation point of his reputations on ``Yes" and loses, the number of his reputation points is reduced by 1; if his forecasts is successful, he should be rewarded (1-p0)/p0 reputation points. The quantity (1-p0)/p0 is the return (reward/bet) ratio for bets on ``Yes''. In this way, if the reference model is correct, the expected return that he gains from this bet is 0. This rule also applies to probability forecasts. Suppose that p is the occurrence probability of an earthquake given by the forecaster. We can regard the forecaster as splitting 1 reputation point by betting p on ``Yes'' and 1-p on ``No''. In this way, the forecaster's expected pay-off based on the reference model is still 0. From the viewpoints of both the reference model and the forecaster, the rule for rewarding and punishment is fair. This method is also extended to the continuous case of point process models, where the reputation points bet by the forecaster become a continuous mass on the space-time-magnitude range of interest. We also calculate the upper bound of the gambling score when the true model is a renewal process, the stress release model or the ETAS model and when the reference model is the Poisson model.

  18. 7 CFR 1.626 - What regulations apply to a case referred for a hearing?

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... referred for a hearing? (a) If NFS refers the case to OALJ, these regulations will continue to apply to the hearing process. (b) If NFS refers the case to the Department of the Interior's Office of Hearing and Appeals, the regulations at 43 CFR 45.1 et seq. will apply from that point. (c) If NFS refers the case to...

  19. 7 CFR 1.626 - What regulations apply to a case referred for a hearing?

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... referred for a hearing? (a) If NFS refers the case to OALJ, these regulations will continue to apply to the hearing process. (b) If NFS refers the case to the Department of the Interior's Office of Hearing and Appeals, the regulations at 43 CFR 45.1 et seq. will apply from that point. (c) If NFS refers the case to...

  20. 7 CFR 1.626 - What regulations apply to a case referred for a hearing?

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... referred for a hearing? (a) If NFS refers the case to OALJ, these regulations will continue to apply to the hearing process. (b) If NFS refers the case to the Department of the Interior's Office of Hearing and Appeals, the regulations at 43 CFR 45.1 et seq. will apply from that point. (c) If NFS refers the case to...

  1. 7 CFR 1.626 - What regulations apply to a case referred for a hearing?

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... referred for a hearing? (a) If NFS refers the case to OALJ, these regulations will continue to apply to the hearing process. (b) If NFS refers the case to the Department of the Interior's Office of Hearing and Appeals, the regulations at 43 CFR 45.1 et seq. will apply from that point. (c) If NFS refers the case to...

  2. 7 CFR 1.626 - What regulations apply to a case referred for a hearing?

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... referred for a hearing? (a) If NFS refers the case to OALJ, these regulations will continue to apply to the hearing process. (b) If NFS refers the case to the Department of the Interior's Office of Hearing and Appeals, the regulations at 43 CFR 45.1 et seq. will apply from that point. (c) If NFS refers the case to...

  3. L1 libration point manned space habitat

    NASA Technical Reports Server (NTRS)

    Luttges, Marvin; Johnson, Steve; Banks, Gary; Johnson, Richard; Meyer, Christian; Pepin, Scott; Macelroy, Robert

    1989-01-01

    Second generation stations or Manned Space Habitats (MSHs) are discussed for an Earth-Moon libration point and in lunar orbit. The conceptual design of such a station is outlined. Systems and subsystems described reflect anticipation of moderate technology growth. The evolution of the L1 environments is discussed, several selected subsystems are outlined, and how the L1 MSH will complete some of its activities is described.

  4. Validation of a modification to Performance-Tested Method 010403: microwell DNA hybridization assay for detection of Listeria spp. in selected foods and selected environmental surfaces.

    PubMed

    Alles, Susan; Peng, Linda X; Mozola, Mark A

    2009-01-01

    A modification to Performance-Tested Method 010403, GeneQuence Listeria Test (DNAH method), is described. The modified method uses a new media formulation, LESS enrichment broth, in single-step enrichment protocols for both foods and environmental sponge and swab samples. Food samples are enriched for 27-30 h at 30 degrees C, and environmental samples for 24-48 h at 30 degrees C. Implementation of these abbreviated enrichment procedures allows test results to be obtained on a next-day basis. In testing of 14 food types in internal comparative studies with inoculated samples, there were statistically significant differences in method performance between the DNAH method and reference culture procedures for only 2 foods (pasteurized crab meat and lettuce) at the 27 h enrichment time point and for only a single food (pasteurized crab meat) in one trial at the 30 h enrichment time point. Independent laboratory testing with 3 foods showed statistical equivalence between the methods for all foods, and results support the findings of the internal trials. Overall, considering both internal and independent laboratory trials, sensitivity of the DNAH method relative to the reference culture procedures was 90.5%. Results of testing 5 environmental surfaces inoculated with various strains of Listeria spp. showed that the DNAH method was more productive than the reference U.S. Department of Agriculture-Food Safety and Inspection Service (USDA-FSIS) culture procedure for 3 surfaces (stainless steel, plastic, and cast iron), whereas results were statistically equivalent to the reference method for the other 2 surfaces (ceramic tile and sealed concrete). An independent laboratory trial with ceramic tile inoculated with L. monocytogenes confirmed the effectiveness of the DNAH method at the 24 h time point. Overall, sensitivity of the DNAH method at 24 h relative to that of the USDA-FSIS method was 152%. The DNAH method exhibited extremely high specificity, with only 1% false-positive reactions overall.

  5. Flights between a neighborhoods of unstable libration points of Sun-Earth system

    NASA Astrophysics Data System (ADS)

    Surkova, Valerya; Shmyrov, Vasily

    2018-05-01

    In this paper we study the problem of constructing impulse flights between neighborhoods of unstable collinear libration points of the Sun-Earth system [1]. Such maneuvering in near-Earth space may prove to be in demand in modern space navigation. For example, such a maneuvering was done by the space vehicle GENESIS. Three test points are chosen for the implementation of the impulse control, in order to move to a neighborhood of the libration point L2. It is shown that the earlier on the exit from the vicinity of the libration point L1 impulse control was realized, the sooner the neighborhood L2 was achieved. Separated from this problem, the problem of optimal control in the neighborhood of L2 was considered and a form of stabilizing control is presented.

  6. Hypervelocity Inflight Trajectory Scatter (HITS) Code. User’s Manual

    DTIC Science & Technology

    1976-04-01

    referred to as skewness. The fourth central moment is referred to as kurtosis and provides an additional measure of the clustering of the distribution... clustering of data points in the resulting "scatter diagram" would indicate correlation. The correlation can be quantified by fit- ting a straight line...10- *4 U* 0%.0 Coo IX wV~ Z de *I *- 0 On Wa )I GMX Ŕ.~ Ot. *P0 WX #- % OW- W 00WIj u +,- >ot o-O- oW cbok~ o*9 lWI $ Wld6 0000000N000 0 4 00 6 6

  7. Elevated lactate during psychogenic hyperventilation.

    PubMed

    ter Avest, E; Patist, F M; Ter Maaten, J C; Nijsten, M W N

    2011-04-01

    Elevated arterial lactate levels are closely related to morbidity and mortality in various patient categories. In the present retrospective study, the relation between arterial lactate, partial pressure of carbon dioxide (Pco(2)) and pH was systematically investigated in patients who visited the emergency department (ED) with psychogenic hyperventilation. Over a 5-month period, all the patients who visited the ED of a university hospital with presumed psychogenic hyperventilation were evaluated. Psychogenic hyperventilation was presumed to be present when an increased respiratory rate (>20 min) was documented at or before the ED visit and when somatic causes explaining the hyperventilation were absent. Arterial blood gas and lactate levels (reference values 0.5-1.5 mmol/l) were immediately measured by a point-of-care analyser that was managed and calibrated by the central laboratory. During the study period, 46 patients were diagnosed as having psychogenic hyperventilation. The median (range) Pco(2) for this group was 4.3 (2.0-5.5) kPa, the pH was 7.47 (7.40-7.68) and the lactate level was 1.2 (0.5-4.4) mmol/l. 14 participants (30%) had a lactate level above the reference value of 1.5 mmol/l. Pco(2) was the most important predictor of lactate in multivariate analysis. None of the participants underwent any medical treatment other than observation at the ED or had been hospitalised after their ED visit. In patients with psychogenic hyperventilation, lactate levels are frequently elevated. Whereas high lactates are usually associated with acidosis and an increased risk of poor outcome, in patients with psychogenic hyperventilation, high lactates are associated with hypocapnia and alkalosis. In this context, elevated arterial lactate levels should not be regarded as an adverse sign.

  8. A note on libration point orbits, temporary capture and low-energy transfers

    NASA Astrophysics Data System (ADS)

    Fantino, E.; Gómez, G.; Masdemont, J. J.; Ren, Y.

    2010-11-01

    In the circular restricted three-body problem (CR3BP) the weak stability boundary (WSB) is defined as a boundary set in the phase space between stable and unstable motion relative to the second primary. At a given energy level, the boundaries of such region are provided by the stable manifolds of the central objects of the L1 and L2 libration points, i.e., the two planar Lyapunov orbits. Besides, the unstable manifolds of libration point orbits (LPOs) around L1 and L2 have been identified as responsible for the weak or temporary capture around the second primary of the system. These two issues suggest the existence of natural dynamical channels between the Earth's vicinity and the Sun-Earth libration points L1 and L2. Furthermore, it has been shown that the Sun-Earth L2 central unstable manifolds can be linked, through an heteroclinic connection, to the central stable manifolds of the L2 point in the Earth-Moon three-body problem. This concept has been applied to the design of low energy transfers (LETs) from the Earth to the Moon. In this contribution we consider all the above three issues, i.e., weak stability boundaries, temporary capture and low energy transfers, and we discuss the role played by the invariant manifolds of LPOs in each of them. The study is made in the planar approximation.

  9. The Hb E (HBB: c.79G>A), Mean Corpuscular Volume, Mean Corpuscular Hemoglobin Cutoff Points in Double Heterozygous Hb E/- -SEA α-Thalassemia-1 Carriers are Dependent on Hemoglobin Levels.

    PubMed

    Leckngam, Prapapun; Limweeraprajak, Ektong; Kiewkarnkha, Tiemjan; Tatu, Thanusak

    2017-01-01

    Identifying double heterozygosities in Hb E (HBB: c.79 G>A)/- - SEA (Southeast Asian) (α-thalassemia-1) (α-thal-1) in patients first diagnosed as carrying Hb E is important in thalassemia control. Low Hb E, mean corpuscular volume (MCV) and mean corpuscular hemoglobin (Hb) (MCH) levels have been observed in this double heterozygosity. However, the cutoff points of these parameters have never been systematically established. Here, we analyzed Hb E and red blood cell (RBC) parameters in 372 Hb E patients grouped by Hb levels, by the status of - - SEA and -α 3.7 (α-thal-2; rightward) deletions, to establish the cutoff points. Then, the established cutoff points were evaluated in 184 Hb E patients. It was found that the cutoff points of Hb E, MCV, MCH were significantly dependent on the Hb levels. In the group having Hb levels <10.0 g/dL, the cutoff points of Hb E, MCV and MCH were 21.2%, 64.9 fL and 21.0 pg, respectively, and were 25.6%, 72.8 fL and 23.9 pg, respectively, in the group having Hb levels 10.0-11.9 g/dL. Finally, in the group having Hb levels ≥12.0 g/dL, the cutoff points of Hb E, MCV and MCH were 27.1%, 76.7 fL and 25.3 pg, respectively. Thus, to screen for the double heterozygous Hb E/- - SEA anomaly in patients initially diagnosed as carrying Hb E, the Hb levels must be taken into account in choosing the suitable cutoff points of these three parameters.

  10. Validation of reference genes for gene expression analysis in olive (Olea europaea) mesocarp tissue by quantitative real-time RT-PCR

    PubMed Central

    2014-01-01

    Background Gene expression analysis using quantitative reverse transcription PCR (qRT-PCR) is a robust method wherein the expression levels of target genes are normalised using internal control genes, known as reference genes, to derive changes in gene expression levels. Although reference genes have recently been suggested for olive tissues, combined/independent analysis on different cultivars has not yet been tested. Therefore, an assessment of reference genes was required to validate the recent findings and select stably expressed genes across different olive cultivars. Results A total of eight candidate reference genes [glyceraldehyde 3-phosphate dehydrogenase (GAPDH), serine/threonine-protein phosphatase catalytic subunit (PP2A), elongation factor 1 alpha (EF1-alpha), polyubiquitin (OUB2), aquaporin tonoplast intrinsic protein (TIP2), tubulin alpha (TUBA), 60S ribosomal protein L18-3 (60S RBP L18-3) and polypyrimidine tract-binding protein homolog 3 (PTB)] were chosen based on their stability in olive tissues as well as in other plants. Expression stability was examined by qRT-PCR across 12 biological samples, representing mesocarp tissues at various developmental stages in three different olive cultivars, Barnea, Frantoio and Picual, independently and together during the 2009 season with two software programs, GeNorm and BestKeeper. Both software packages identified GAPDH, EF1-alpha and PP2A as the three most stable reference genes across the three cultivars and in the cultivar, Barnea. GAPDH, EF1-alpha and 60S RBP L18-3 were found to be most stable reference genes in the cultivar Frantoio while 60S RBP L18-3, OUB2 and PP2A were found to be most stable reference genes in the cultivar Picual. Conclusions The analyses of expression stability of reference genes using qRT-PCR revealed that GAPDH, EF1-alpha, PP2A, 60S RBP L18-3 and OUB2 are suitable reference genes for expression analysis in developing Olea europaea mesocarp tissues, displaying the highest level of expression stability across three different olive cultivars, Barnea, Frantoio and Picual, however the combination of the three most stable reference genes do vary amongst individual cultivars. This study will provide guidance to other researchers to select reference genes for normalization against target genes by qPCR across tissues obtained from the mesocarp region of the olive fruit in the cultivars, Barnea, Frantoio and Picual. PMID:24884716

  11. Identification of Reference Genes for Quantitative Gene Expression Studies in a Non-Model Tree Pistachio (Pistacia vera L.)

    PubMed Central

    Moazzam Jazi, Maryam; Ghadirzadeh Khorzoghi, Effat; Botanga, Christopher; Seyedi, Seyed Mahdi

    2016-01-01

    The tree species, Pistacia vera (P. vera) is an important commercial product that is salt-tolerant and long-lived, with a possible lifespan of over one thousand years. Gene expression analysis is an efficient method to explore the possible regulatory mechanisms underlying these characteristics. Therefore, having the most suitable set of reference genes is required for transcript level normalization under different conditions in P. vera. In the present study, we selected eight widely used reference genes, ACT, EF1α, α-TUB, β-TUB, GAPDH, CYP2, UBQ10, and 18S rRNA. Using qRT-PCR their expression was assessed in 54 different samples of three cultivars of P. vera. The samples were collected from different organs under various abiotic treatments (cold, drought, and salt) across three time points. Several statistical programs (geNorm, NormFinder, and BestKeeper) were applied to estimate the expression stability of candidate reference genes. Results obtained from the statistical analysis were then exposed to Rank aggregation package to generate a consensus gene rank. Based on our results, EF1α was found to be the superior reference gene in all samples under all abiotic treatments. In addition to EF1α, ACT and β-TUB were the second best reference genes for gene expression analysis in leaf and root. We recommended β-TUB as the second most stable gene for samples under the cold and drought treatments, while ACT holds the same position in samples analyzed under salt treatment. This report will benefit future research on the expression profiling of P. vera and other members of the Anacardiaceae family. PMID:27308855

  12. Identification of Reference Genes for Quantitative Gene Expression Studies in a Non-Model Tree Pistachio (Pistacia vera L.).

    PubMed

    Moazzam Jazi, Maryam; Ghadirzadeh Khorzoghi, Effat; Botanga, Christopher; Seyedi, Seyed Mahdi

    2016-01-01

    The tree species, Pistacia vera (P. vera) is an important commercial product that is salt-tolerant and long-lived, with a possible lifespan of over one thousand years. Gene expression analysis is an efficient method to explore the possible regulatory mechanisms underlying these characteristics. Therefore, having the most suitable set of reference genes is required for transcript level normalization under different conditions in P. vera. In the present study, we selected eight widely used reference genes, ACT, EF1α, α-TUB, β-TUB, GAPDH, CYP2, UBQ10, and 18S rRNA. Using qRT-PCR their expression was assessed in 54 different samples of three cultivars of P. vera. The samples were collected from different organs under various abiotic treatments (cold, drought, and salt) across three time points. Several statistical programs (geNorm, NormFinder, and BestKeeper) were applied to estimate the expression stability of candidate reference genes. Results obtained from the statistical analysis were then exposed to Rank aggregation package to generate a consensus gene rank. Based on our results, EF1α was found to be the superior reference gene in all samples under all abiotic treatments. In addition to EF1α, ACT and β-TUB were the second best reference genes for gene expression analysis in leaf and root. We recommended β-TUB as the second most stable gene for samples under the cold and drought treatments, while ACT holds the same position in samples analyzed under salt treatment. This report will benefit future research on the expression profiling of P. vera and other members of the Anacardiaceae family.

  13. Spatial Updating Strategy Affects the Reference Frame in Path Integration.

    PubMed

    He, Qiliang; McNamara, Timothy P

    2018-06-01

    This study investigated how spatial updating strategies affected the selection of reference frames in path integration. Participants walked an outbound path consisting of three successive waypoints in a featureless environment and then pointed to the first waypoint. We manipulated the alignment of participants' final heading at the end of the outbound path with their initial heading to examine the adopted reference frame. We assumed that the initial heading defined the principal reference direction in an allocentric reference frame. In Experiment 1, participants were instructed to use a configural updating strategy and to monitor the shape of the outbound path while they walked it. Pointing performance was best when the final heading was aligned with the initial heading, indicating the use of an allocentric reference frame. In Experiment 2, participants were instructed to use a continuous updating strategy and to keep track of the location of the first waypoint while walking the outbound path. Pointing performance was equivalent regardless of the alignment between the final and the initial headings, indicating the use of an egocentric reference frame. These results confirmed that people could employ different spatial updating strategies in path integration (Wiener, Berthoz, & Wolbers Experimental Brain Research 208(1) 61-71, 2011), and suggested that these strategies could affect the selection of the reference frame for path integration.

  14. Reference values for Lactate Pro 2™ in fetal blood sampling during labor: a cross-sectional study.

    PubMed

    Birgisdottir, Brynhildur Tinna; Holzmann, Malin; Varli, Ingela Hulthén; Graner, Sofie; Saltvedt, Sissel; Nordström, Lennart

    2017-04-01

    Lactate Pro™ (LP1) is the only lactate meter evaluated for fetal scalp blood sampling (FBS) in intrapartum use. The reference values for this meter are: normal value <4.2 mmol/L, preacidemia 4.2-4.8 mmol/L, and acidemia >4.8 mmol/L. The production of this meter has been discontinued. An updated version, Lactate Pro 2TM (LP2), has been launched and is shown to be differently calibrated. The aims of the study were to retrieve a conversion equation to convert lactate values in FBS measured with LP2 to an estimated value if using LP1 and to define reference values for clinical management when using LP2. A cross-sectional study was conducted at a university hospital in Sweden. A total of 113 laboring women with fetal heart rate abnormalities on cardiotocography (CTG) had FBS carried out. Lactate concentration was measured bedside with both LP1 and LP2 from the same blood sample capillary. A linear regression model was constructed to retrieve a conversion equation to convert LP2 values to LP1 values. LP2 measured higher values than LP1 in all analyses. We found that 4.2 mmol/L with LP1 corresponded to 6.4 mmol/L with LP2. Likewise, 4.8 mmol/L with LP1 corresponded to 7.3 mmol/L with LP2. The correlation between the analyses was excellent (Spearman's rank correlation, r=0.97). We recommend the following guidelines when interpreting lactate concentration in FBS with LP2: <6.4 mmol/L to be interpreted as normal, 6.4-7.3 mmol/L as preacidemia indicating a follow-up FBS within 20-30 min, and >7.3 mmol/L as acidemia indicating intervention.

  15. Relative bioavailability of a newly developed 5-mg levomethadone hydrochloride IR tablet (L-Polamidon® 5 mg tablets) in comparison with the 5-mg levomethadone hydrochloride oral solution (L-Polamidon® solution for substitution) as reference product.

    PubMed

    Blume, Henning H; Wedemeyer, Ralf-Steven; Donath, Frank; Roscher, Katrin; Elvert, Gerd; Wagner, Daniel; Bley, Oliver; Vuia, Alexander; Todorova-Sanjari, Marina; Villalobos, Ramon; Schug, Barbara

    2015-04-01

    To establish the relative bioavailability (rBA) between two p.o. 5-mg levomethadone hydrochloride formulations, i.e., L-Polamidon® 5 mg tablets (test) vs. L-Polamidon® solution for substitution (reference). To assess the safety and tolerability of both formulations. A total of 33 healthy male subjects, aged 29 ± 6 years (BMI: 23.9 ± 2.5 kg/m2) completed this single center, open-label, randomized, 2-period cross-over study with single dose administrations under fasting conditions and coadministration with naltrexone for safety reasons. Administrations of both investigational products were separated by a washout period of at least 2 weeks, i.e., 13 treatmentfree days. The total dose for each subject was 2 x 5 mg resulting in 10 mg levomethadone hydrochloride. For pharmacokinetic evaluation, blood samples were withdrawn until 72 hours postdose. A validated non-stereoselective liquid chromatography-tandem mass spectroscopy method (LC-MS/MS) was applied for the determination of levomethadone in plasma. The lower limit of quantitation was 0.100 ng/mL. Adverse events were descriptively analyzed in the study population. The geometric means of the parameters related with the extent of total exposure of levomethadone, i.e., AUC(0-tlast) and AUC(0-∞), were 244.422 ng x h/mL and 332.999 ng x h/mL for test and 246.837 ng x h/mL and 329.467 ng×h/mL for reference, respectively. The geometric means of the peak exposure for levomethadone, i.e., Cmax, were 8.923 ng/mL for test and 8.635 ng/mL for reference. The point estimates (PEs) of the Test/Reference (T/R) adjusted geometric mean ratios of AUC(0-last), AUC(0-∞), and C(max) were 99.20%, 101.42%, and 104.11%, respectively, and all of them showed 90%-confidence intervals (CIs) within the range of 80.00 - 125.00% as suggested by regulatory requirements for bioequivalence assessment In total, 21 subjects experienced 55 AEs during the study, the most frequently reported AE, i.e., headache, accounted for 13 out of the total 55 AEs (23.6%) and no AEs of severe intensity were reported. Bioequivalence could be demonstrated in terms of rate and extent of absorption after administration of test and reference products under naltrexone protection. Concerning the safety evaluation, no negative implications on the possible use of the test formulation could be determined.

  16. Targeting β-arrestin2 in the treatment of l-DOPA–induced dyskinesia in Parkinson’s disease

    PubMed Central

    Urs, Nikhil M.; Bido, Simone; Peterson, Sean M.; Daigle, Tanya L.; Bass, Caroline E.; Gainetdinov, Raul R.; Bezard, Erwan; Caron, Marc G.

    2015-01-01

    Parkinson’s disease (PD) is characterized by severe locomotor deficits and is commonly treated with the dopamine (DA) precursor l-3,4-dihydroxyphenylalanine (l-DOPA), but its prolonged use causes dyskinesias referred to as l-DOPA–induced dyskinesias (LIDs). Recent studies in animal models of PD have suggested that dyskinesias are associated with the overactivation of G protein-mediated signaling through DA receptors. β-Arrestins desensitize G protein signaling at DA receptors (D1R and D2R) in addition to activating their own G protein-independent signaling events, which have been shown to mediate locomotion. Therefore, targeting β-arrestins in PD l-DOPA therapy might prove to be a desirable approach. Here we show in a bilateral DA-depletion mouse model of Parkinson’s symptoms that genetic deletion of β-arrestin2 significantly limits the beneficial locomotor effects while markedly enhancing the dyskinesia-like effects of acute or chronic l-DOPA treatment. Viral rescue or overexpression of β-arrestin2 in knockout or control mice either reverses or protects against LIDs and its key biochemical markers. In other more conventional animal models of DA neuron loss and PD, such as 6-hydroxydopamine–treated mice or rats and 1-methyl-4-phenyl-1,2,3,6-tetrahydropyridine–treated nonhuman primates, β-arrestin2 overexpression significantly reduced dyskinesias while maintaining the therapeutic effect of l-DOPA. Considerable efforts are being spent in the pharmaceutical industry to identify therapeutic approaches to block LIDs in patients with PD. Our results point to a potential therapeutic approach, whereby development of either a genetic or pharmacological intervention to enhance β-arrestin2- or limit G protein-dependent D1/D2R signaling could represent a more mechanistically informed strategy. PMID:25918399

  17. Preparation of canine C-reactive protein serum reference material: A feasibility study.

    PubMed

    Canalias, Francesca; Piñeiro, Matilde; Pato, Raquel; Peña, Raquel; Bosch, Lluís; Soler, Lourdes; García, Natalia; Lampreave, Fermín; Saco, Yolanda; Bassols, Anna

    2018-03-01

    The availability of a species-specific reference material is essential for the harmonization of results obtained in different laboratories by different methods. We describe the preparation of a canine C-reactive protein (cCRP) serum reference material containing purified cCRP stabilized in a serum matrix. The material can be used by manufacturers to assign values to their calibrator and control materials. The serum matrix was obtained using blood collected from healthy dogs, stabilized and submitted for a delipidation process. The reference material was prepared by diluting purified cCRP in the serum matrix containing 1.0 mol/L HEPES buffer, 3.0 mmol/L calcium chloride, 80,000 kUI/L aprotinin, and 1.0 mmol/L benzamidine hydrochloride monohydrate at a pH of 7.2, and dispensing (0.5 mL) the matrix into vials that were then frozen. The pilot batch of 200 vials was shown to be homogeneous and stable after a stability study at various temperatures and over a total time of 110 days. The prepared material was submitted to an assignment value study. Eight laboratories from different European countries participated by using the same reagents for an immunoturbidimetric method adapted for different analyzers. The obtained cCRP concentration in the reference material was 78.5 mg/L with an expanded uncertainty (k = 2) of 4.2 mg/L. Canine C-reactive protein serum reference material has been produced that allows harmonization of results obtained by different methods and different laboratories, thus reducing the possibility of errors and misunderstandings. © 2018 American Society for Veterinary Clinical Pathology.

  18. Publications - RI 2006-2 v. 1.0.1 | Alaska Division of Geological &

    Science.gov Websites

    , R.J., Werdon, M.B., Freeman, L.K., Smith, R.L., and Szumigala, D.J. Publication Date: Nov 2006 Bibliographic Reference Athey, J.E., Newberry, R.J., Werdon, M.B., Freeman, L.K., Smith, R.L., and Szumigala

  19. [Effects of hydrogen sulfide on the secretion of cytokines in macrophages of deep partial-thickness burn wound in rats].

    PubMed

    Li, Y; Xu, D B; Wang, H J

    2016-07-20

    To analyze the effects of exogenous hydrogen sulfide on the secretion of growth factors basic fibroblast growth factor (bFGF) and transforming growth factor β1 (TGF-β1), as well as inflammatory mediators tumor necrosis factor α (TNF-α) and interleukin 1β (IL-1β) in macrophages of deep partial-thickness burn wound in rats. Seventy-eight SD rats were divided into normal control group (n=6), pure burn group, sodium hydrosulfide group, propargylglycine (PPG) group, and sodium hydrosulfide+ PPG group according to the random number table, with 18 rats in each of the latter four groups. Rats in normal control group did not receive any treatment, while rats in the other four groups were inflicted with 5% total burn surface area deep partial-thickness scald (hereinafter referred to as burn) on the back. Immediately after burn, rats in pure burn group, sodium hydrosulfide group, and group PPG were intraperitoneally injected with saline 2 mL/kg, sodium hydrosulfide 56 μmol/kg, and PPG 45 mg/kg respectively, while those in sodium hydrosulfide+ PPG group were intraperitoneally injected with sodium hydrosulfide 56 μmol/kg and PPG 45 mg/kg, once a day till the day before harvesting specimen. Six rats of normal control group fed for one week, and 6 rats from each of the rest four groups on post injury day (PID) 3, 7, 14 were collected respectively. Normal skin on the back of rats in normal control group and tissue in the base of wound of rats in the other four groups were harvested to isolate macrophages, and then the content of bFGF, TGF-β1, TNF-α, and IL-1β in culture supernatant of macrophages was detected with enzyme-linked immunosorbent assay. Data were processed with one-way analysis of variance, analysis of variance of factorial design, and LSD test. Compared with that of normal control group [(42.6±2.5) and (18±4) pg/mL], the content of bFGF and TGF-β1 in culture supernatant of macrophages of rats in pure burn group was obviously increased at each time point (with P values below 0.01), peaking on PID 14 at (141.6±7.7) and (580±16) pg/mL respectively. Compared with that of pure burn group, the content of bFGF and TGF-β1 in culture supernatant of macrophages of rats in sodium hydrosulfide group was obviously increased at each time point (with P values below 0.01), peaking on PID 14 at (193.7±10.9) and (793±12) pg/mL respectively, while the content of bFGF and TGF-β1 in culture supernatant of macrophages of rats in group PPG was obviously decreased at each time point (with P values below 0.01), reaching the nadir on PID 3 at (62.0±7.1) and (170±10) pg/mL respectively. The content of bFGF and TGF-β1 in culture supernatant of macrophages of rats in sodium hydrosulfide+ PPG group was obviously lower than that of sodium hydrosulfide group but obviously higher than that of group PPG at each time point (with P values below 0.01), peaking on PID 14 at (151.3±9.0) and (579±9) pg/mL respectively. Compared with that of normal control group [(97±6) and (31±6) pg/mL], the content of TNF-α and IL-1β in culture supernatant of macrophages of rats in pure burn group was obviously increased at each time point (with P values below 0.01), peaking on PID 3 at (924±8) and (290±10) pg/mL respectively. Compared with that of pure burn group, the content of TNF-α and IL-1β in culture supernatant of macrophages of rats in sodium hydrosulfide group was obviously decreased at each time point (with P values below 0.01), reaching the nadir on PID 14 at (346±10) and (120±5) pg/mL respectively, while the content of TNF-α and IL-1β in culture supernatant of macrophages of rats in group PPG was obviously increased at each time point (with P values below 0.01), peaking on PID 3 at (1 232±13) and (410±10) pg/mL respectively. The content of TNF-α and IL-1β in culture supernatant of macrophages of rats in sodium hydrosulfide+ PPG group was obviously higher than that of sodium hydrosulfide group but obviously lower than that of group PPG at each time point (with P values below 0.01), reaching the nadir on PID 14 at (488±16) and (144±6) pg/mL respectively. Supplementation of exogenous hydrogen sulfide in small dosage can increase the secretion of growth factors bFGF and TGF-β1 in macrophages of wound in rats with deep partial-thickness burn in the early stage and reduce the release of inflammatory mediators TNF-α and IL-1β in the meantime, thus affecting the healing of wound.

  20. Single point aerosol sampling: evaluation of mixing and probe performance in a nuclear stack.

    PubMed

    Rodgers, J C; Fairchild, C I; Wood, G O; Ortiz, C A; Muyshondt, A; McFarland, A R

    1996-01-01

    Alternative reference methodologies have been developed for sampling of radionuclides from stacks and ducts, which differ from the methods previously required by the United States Environmental Protection Agency. These alternative reference methodologies have recently been approved by the U.S. EPA for use in lieu of the current standard techniques. The standard EPA methods are prescriptive in selection of sampling locations and in design of sampling probes whereas the alternative reference methodologies are performance driven. Tests were conducted in a stack at Los Alamos National Laboratory to demonstrate the efficacy of some aspects of the alternative reference methodologies. Coefficients of variation of velocity, tracer gas, and aerosol particle profiles were determined at three sampling locations. Results showed that numerical criteria placed upon the coefficients of variation by the alternative reference methodologies were met at sampling stations located 9 and 14 stack diameters from the flow entrance, but not at a location that was 1.5 diameters downstream from the inlet. Experiments were conducted to characterize the transmission of 10 microns aerodynamic diameter liquid aerosol particles through three types of sampling probes. The transmission ratio (ratio of aerosol concentration at the probe exit plane to the concentration in the free stream) was 107% for a 113 L min-1 (4-cfm) anisokinetic shrouded probe, but only 20% for an isokinetic probe that follows the existing EPA standard requirements. A specially designed isokinetic probe showed a transmission ratio of 63%. The shrouded probe performance would conform to the alternative reference methodologies criteria; however, the isokinetic probes would not.

  1. Radiant Temperature Nulling Radiometer

    NASA Technical Reports Server (NTRS)

    Ryan, Robert (Inventor)

    2003-01-01

    A self-calibrating nulling radiometer for non-contact temperature measurement of an object, such as a body of water, employs a black body source as a temperature reference, an optomechanical mechanism, e.g., a chopper, to switch back and forth between measuring the temperature of the black body source and that of a test source, and an infrared detection technique. The radiometer functions by measuring radiance of both the test and the reference black body sources; adjusting the temperature of the reference black body so that its radiance is equivalent to the test source; and, measuring the temperature of the reference black body at this point using a precision contact-type temperature sensor, to determine the radiative temperature of the test source. The radiation from both sources is detected by an infrared detector that converts the detected radiation to an electrical signal that is fed with a chopper reference signal to an error signal generator, such as a synchronous detector, that creates a precision rectified signal that is approximately proportional to the difference between the temperature of the reference black body and that of the test infrared source. This error signal is then used in a feedback loop to adjust the reference black body temperature until it equals that of the test source, at which point the error signal is nulled to zero. The chopper mechanism operates at one or more Hertz allowing minimization of l/f noise. It also provides pure chopping between the black body and the test source and allows continuous measurements.

  2. Citation success of different publication types: a case study on all references in psychology publications from the German-speaking countries (D-A-CH-L-L) in 2009, 2010, and 2011.

    PubMed

    Krampen, Günter; Weiland, Peter; Wiesenhütter, Jürgen

    Scientometric data on the citation success of different publication types and publication genres in psychology publications are presented. Data refer to references that are cited in these scientific publications and that are documented in PSYNDEX, the exhaustive database of psychology publications from the German-speaking countries either published in German or in English language. Firstly, data analyses refer to the references that are cited in publications of 2009 versus 2010 versus 2011. With reference to all cited references, the portion of journal articles ranges from 57 to 61 %, of books from 22 to 24 %, and of book chapters from 14 to 15 %, with a rather high stability across the three publication years analysed. Secondly, data analyses refer to the numbers of cited references from the German-speaking countries, which are also documented in PSYNDEX. These compose about 11 % of all cited references indicating that nearly 90 % of the references cited are of international and/or interdisciplinary publications not stemming from the German-speaking countries. The subsample shows the proportion of journal articles, books, and chapters, and these are very similar to the percentages identified for all references that are cited. Thirdly, analyses refer to document type, scientific genre, and psychological sub-discipline of the most frequently cited references in the psychology publications. The frequency of top-cited references of books and book chapters is almost equal to that of journal articles; two-thirds of the top-cited references are non-empirical publications, only one-third are empirical publications. Top-cited references stem particularly from clinical psychology, experimental psychology, as well as tests, testing and psychometrics. In summary, the results point to the fact that citation analyses, which are limited to journal papers, tend to neglect very high portions of references that are cited in scientific publications.

  3. Method comparison and validation of a prototype device for measurement of ionized calcium concentrations cow-side against a point-of-care instrument and a benchtop blood-gas analyzer reference method.

    PubMed

    Neves, R C; Stokol, T; Bach, K D; McArt, J A A

    2018-02-01

    The objective of this study was to assess an optimized ion-selective electrode Ca-module prototype as a potential cow-side device for ionized Ca (iCa) measurements in bovine blood. A linearity experiment showed no deviation from linearity over a range of iCa concentrations compared with a commercial point-of-care (POC) device commonly used in the field (POC VS ; VetScan i-STAT, Abaxis North America, Union City, CA) and a laboratory gold standard benchtop blood-gas analyzer [reference analyzer (RA); ABL-800 FLEX, Radiometer Medical, Copenhagen, Denmark]. Coefficient of variation on 3 samples with high, within-range, and low iCa concentrations ranged from 1.0 to 3.9% for the prototype. A follow-up validation experiment was performed, in which our objectives were to (1) assess the performance of the prototype cow-side against the POC VS (farm gold-standard) using fresh non-anticoagulated whole-blood samples; (2) assess the performance of the prototype and the POC VS against the RA in a diagnostic laboratory using blood collected in a heparin-balanced syringe; and (3) assess the agreement of the prototype and POC VS on-farm (fresh non-anticoagulated whole blood) against the RA on heparin-balanced blood. Finally, sensitivity and specificity of the results obtained by the prototype and the POC VS cow-side compared with the results obtained by the laboratory RA using 3 different iCa cut points for classification of subclinical hypocalcemia were calculated. A total of 101 periparturient Holstein cows from 3 dairy farms in New York State were used for the second experiment. Ionized Ca results from the prototype cow-side were, on average, 0.06 mmol/L higher than the POC VS . With heparin-balanced samples under laboratory conditions, the prototype and POC VS measured an average 0.04 mmol/L higher and lower, respectively, compared with the RA. Results from the prototype and POC VS cow-side were 0.01 mmol/L higher and 0.05 mmol/L lower, respectively, compared with results from the laboratory RA on heparinized blood. Sensitivity and specificity for the prototype and the POC VS under farm conditions at 3 potential subclinical hypocalcemia cut points were 100 and ≥93.5%, respectively. This novel ion-selective electrode Ca-module could become a rapid low-cost tool for assessing iCa cow-side, while qualitatively allowing classification of subclinical hypocalcemia on-farm. The Authors. Published by the Federation of Animal Science Societies and Elsevier Inc. on behalf of the American Dairy Science Association®. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/3.0/).

  4. The new Greiner FC-Mix tubes equal the old Terumo ones and are useful as glucose stabilizer after prolonged storage of samples.

    PubMed

    Bonetti, Graziella; Carta, Mariarosa

    2017-10-15

    The aim of our study is to compare new Greiner tubes containing granulated citrate buffer with the Terumo ones and to verify if they are suitable for glucose stabilization after prolonged storage. In Study 1, blood was collected in two Terumo and two Greiner tubes from 40 healthy volunteers. Samples were stored at room temperature (RT) for 1 and 2 hours, respectively. Comparison was made by Deming regression. In Study 2, glucose was measured in a reference tube (N = 50), according to the ADA-NACB guidelines and in aliquots of Greiner samples maintained un-centrifuged at RT for 1, 2, 4 (N = 50) and 24, 48, 72 hours (N = 35). There were insignificant mixed biases between the Terumo and Greiner tubes. Compared to reference (5.3 mmol/L), glucose concentration in the new tubes was 5.4 (P < 0.05), 5.4 (P < 0.05), 5.3 (P = 0.265), 5.2 (P = 0.156), 5.3 (P < 0.05) and 5.2 (P < 0.05) mmol/L after 1, 2, 4, 24, 48 and 72 hours at RT, respectively. There was no biological difference between any of the time points up to 48 h (bias < ± 1.95%). The study shows that the new tubes perform equally well as the Terumo ones and ensure glucose stabilization up to 48 h as well as permit to create a link between the previous studies demonstrating the clinical utility of granulated citrate buffer and the future ones.

  5. Schistosomiasis, soil-transmitted helminthiasis, and sociodemographic factors influence quality of life of adults in Côte d'Ivoire.

    PubMed

    Fürst, Thomas; Silué, Kigbafori D; Ouattara, Mamadou; N'Goran, Dje N; Adiossan, Lukas G; N'Guessan, Yao; Zouzou, Fabian; Koné, Siaka; N'Goran, Eliézer K; Utzinger, Jürg

    2012-01-01

    Burden of disease estimates are widely used for priority setting in public health and disability-adjusted life years are a powerful "currency" nowadays. However, disability weights, which capture the disability incurred by a typical patient of a certain condition, are fundamental to such burden calculation and their determination remains a widely debated issue. A cross-sectional epidemiological survey was conducted in the recently established Taabo health demographic surveillance system (HDSS) in south-central Côte d'Ivoire, to provide new, population-based evidence on the disability caused by schistosomiasis and soil-transmitted helminthiasis. Parasitological results from stool, urine, and blood examinations were juxtaposed to quality of life (QoL) questionnaire results from 187 adults. A multivariable linear regression model with stepwise backward elimination was used to identify significant associations, considering also sociodemographic characteristics obtained from the Taabo HDSS database. Prevalences for hookworm, Plasmodium spp., Trichuris trichiura, Schistosoma haematobium and Schistosoma mansoni were 39.0%, 18.2%, 2.7%, 2.1% and 2.1%, respectively. S. mansoni and T. trichiura infections of any intensity reduced the participants' self-rated QoL by 16 points (95% confidence interval (CI): 4-29 points) and 13 points (95% CI: 1-24 points), respectively, on a scale from 0 (worst QoL) to 100 points (best QoL). The only other statistically significant effect was a 1-point (95% CI: 0.1-2 points) increase on the QoL scale per one unit increase in a calculated wealth index. We found consistent and significant results on the negative effects of schistosomiasis and soil-transmitted helminthiasis on adults' self-rated QoL, also when taking sociodemographic characteristics into account. Our results warrant further investigation on the disability incurred by helmintic infections and the usefulness of generic QoL questionnaires in this endeavor.

  6. Schistosomiasis, Soil-Transmitted Helminthiasis, and Sociodemographic Factors Influence Quality of Life of Adults in Côte d'Ivoire

    PubMed Central

    Fürst, Thomas; Silué, Kigbafori D.; Ouattara, Mamadou; N'Goran, Dje N.; Adiossan, Lukas G.; N'Guessan, Yao; Zouzou, Fabian; Koné, Siaka; N'Goran, Eliézer K.; Utzinger, Jürg

    2012-01-01

    Background Burden of disease estimates are widely used for priority setting in public health and disability-adjusted life years are a powerful “currency” nowadays. However, disability weights, which capture the disability incurred by a typical patient of a certain condition, are fundamental to such burden calculation and their determination remains a widely debated issue. Methodology A cross-sectional epidemiological survey was conducted in the recently established Taabo health demographic surveillance system (HDSS) in south-central Côte d'Ivoire, to provide new, population-based evidence on the disability caused by schistosomiasis and soil-transmitted helminthiasis. Parasitological results from stool, urine, and blood examinations were juxtaposed to quality of life (QoL) questionnaire results from 187 adults. A multivariable linear regression model with stepwise backward elimination was used to identify significant associations, considering also sociodemographic characteristics obtained from the Taabo HDSS database. Principal Findings Prevalences for hookworm, Plasmodium spp., Trichuris trichiura, Schistosoma haematobium and Schistosoma mansoni were 39.0%, 18.2%, 2.7%, 2.1% and 2.1%, respectively. S. mansoni and T. trichiura infections of any intensity reduced the participants' self-rated QoL by 16 points (95% confidence interval (CI): 4–29 points) and 13 points (95% CI: 1–24 points), respectively, on a scale from 0 (worst QoL) to 100 points (best QoL). The only other statistically significant effect was a 1-point (95% CI: 0.1–2 points) increase on the QoL scale per one unit increase in a calculated wealth index. Conclusions/Significance We found consistent and significant results on the negative effects of schistosomiasis and soil-transmitted helminthiasis on adults' self-rated QoL, also when taking sociodemographic characteristics into account. Our results warrant further investigation on the disability incurred by helmintic infections and the usefulness of generic QoL questionnaires in this endeavor. PMID:23056662

  7. Observing Coronal Mass Ejections from the Sun-Earth L5 Point

    NASA Astrophysics Data System (ADS)

    Gopalswamy, N.; Davila, J. M.; St Cyr, O. C.

    2013-12-01

    Coronal mass ejections (CMEs) are the most energetic phenomenon in the heliosphere and are known to be responsible for severe space weather. Most of the current knowledge on CMEs accumulated over the past few decades has been derived from observations made from the Sun-Earth line, which is not the ideal vantage point to observe Earth-affecting CMEs (Gopalswamy et al., 2011a,b). The STEREO mission viewed CMEs from points away from the Sun-Earth line and demonstrated the importance of such observations in understanding the three-dimensional structure of CMEs and their true kinematics. In this paper, we show that it is advantageous to observe CMEs from the Sun-Earth L5 point in studying CMEs that affect Earth. In particular, these observations are important in identifying that part of the CME that is likely to arrive at Earth. L5 observations are critical for several aspects of CME studies such as: (i) they can also provide near-Sun space speed of CMEs, which is an important input for modeling Earth-arriving CMEs, (ii) backside and frontside CMEs can be readily distinguished even without inner coronal imagers, and (iii) preceding CMEs in the path of Earth-affecting CMEs can be identified for a better estimate of the travel time, which may not be possible from the Sun-Earth line. We also discuss how the L5 vantage point compares with the Sun-Earth L4 point for observing Earth-affecting CMEs. References Gopalswamy, N., Davila, J. M., St. Cyr, O. C., Sittler, E. C., Auchère, F., Duvall, T. L., Hoeksema, J. T., Maksimovic, M., MacDowall, R. J., Szabo, A., Collier, M. R. (2011a), Earth-Affecting Solar Causes Observatory (EASCO): A potential International Living with a Star Mission from Sun-Earth L5 JASTP 73, 658-663, DOI: 10.1016/j.jastp.2011.01.013 Gopalswamy, N., Davila, J. M., Auchère, F., Schou, J., Korendyke, C. M. Shih, A., Johnston, J. C., MacDowall, R. J., Maksimovic, M., Sittler, E., et al. (2011b), Earth-Affecting Solar Causes Observatory (EASCO): a mission at the Sun-Earth L5, Solar Physics and Space Weather Instrumentation IV. Ed. Fineschi, S. & Fennelly, J., Proceedings of the SPIE, Volume 8148, article id. 81480Z, DOI: 10.1117/12.901538

  8. Second language as a compensatory resource for maintaining verbal fluency in bilingual immigrants with schizophrenia.

    PubMed

    Smirnova, D; Walters, J; Fine, J; Muchnik-Rozanov, Y; Paz, M; Lerner, V; Belmaker, R H; Bersudsky, Y

    2015-08-01

    Due to the large migrations over the past three decades, large numbers of individuals with schizophrenia are learning a second language and being seen in clinics in that second language. We conducted within-subject comparisons to clarify the contribution of clinical, linguistic and bilingual features in the first and second languages of bilinguals with schizophrenia. Ten bilingual Russian(L1) and Hebrew(L2) proficient patients, who developed clinical schizophrenia after achieving proficiency in both languages, were selected from 60 candidates referred for the study; they were resident in Israel 7-32 years with 3-10 years from immigration to diagnosis. Clinical, linguistic and fluency markers were coded in transcripts of clinical interviews. There was a trend toward more verbal productivity in the first language (L1) than the second language (L2). Clinical speech markers associated with thought disorder and cognitive impairment (blocking and topic shift) were similar in both languages. Among linguistic markers of schizophrenia, Incomplete syntax and Speech role reference were significantly more frequent in L2 than L1; Lexical repetition and Unclear reference demonstrated a trend in the same direction. For fluency phenomena, Discourse markers were more prevalent in L1 than L2, and Codeswitching was similar across languages, showing that the patients were attuned to the socio-pragmatics of language use. More frequent linguistic markers of schizophrenia in L2 show more impairment in the syntactic/semantic components of language, reflecting greater thought and cognitive dysfunction. Patients are well able to acquire a second language. Nevertheless, schizophrenia finds expression in that language. Finally, more frequent fluency markers in L1 suggests motivation to maintain fluency, evidenced in particular by codeswitched L2 lexical items, a compensatory resource. Copyright © 2015 Elsevier Ltd. All rights reserved.

  9. Body Composition within the First 3 Months: Optimized Correction for Length and Correlation with BMI at 2 Years.

    PubMed

    Hawkes, Colin P; Zemel, Babette S; Kiely, Mairead; Irvine, Alan D; Kenny, Louise C; O'B Hourihane, Jonathan; Murray, Deirdre M

    2016-01-01

    Although early infant growth has implications for future health, body composition reference data in infancy are limited. The aim of this study was to describe reference data for fat mass (FM) and fat-free mass (FFM) corrected for length (L) within the first 3 months and to evaluate if these measures predict the body mass index (BMI) at 2 years. Term infants had air displacement plethysmography performed at birth (n = 1,063) and approximately 2 months later (n = 922, between 49 and 86 days). Age- and sex-specific reference data were generated for FM, FFM, FM/L 3 and FFM/L 2 and compared with BMI at 2 years. FM/L 3 and FFM/L 2 were the optimal indices independent of length. In the first 3 months, mean FM/L 3 increased (males, from 2.7 to 5.9 kg/m 3 ; females, from 3.2 to 6.1 kg/m 3 ), whereas FFM/L 2 remained relatively stable (males, from 11.8 to 12.7 kg/m 2 ; females, from 12.8 to 12.1 kg/m 2 ). The odds of a BMI Z-score ≥2 at 2 years increased with increasing FM (OR 2.7, 95% CI 1.97-3.7) and weight (OR 2.27, 95% CI 1.64-3.13) Z-scores at 2 months. FM/L 3 and FFM/L 2 provide length-independent measures of FM and FFM in infancy. During the first 3 months, there is an increase in FM/L 3 , but not in FFM/L 2 . The weight Z-score at 2 months is as good at predicting BMI at 2 years as body composition parameters. © 2016 S. Karger AG, Basel.

  10. Resonance and Capture of Jupiter Comets

    NASA Astrophysics Data System (ADS)

    Koon, W. S.; Lo, M. W.; Marsden, J. E.; Ross, S. D.

    A number of Jupiter family comets such as Oterma and Gehrels 3 make a rapid transition from heliocentric orbits outside the orbit of Jupiter to heliocentric orbits inside the orbit of Jupiter and vice versa. During this transition, the comet can be captured temporarily by Jupiter for one to several orbits around Jupiter. The interior heliocentric orbit is typically close to the 3:2 resonance while the exterior heliocentric orbit is near the 2:3 resonance. An important feature of the dynamics of these comets is that during the transition, the orbit passes close to the libration points L_1 and L_2, two of the equilibrium points for the restricted three-body problem for the Sun-Jupiter system. Studying the libration point invariant manifold structures for L_1 and L_2 is a starting point for understanding the capture and resonance transition of these comets. For example, the recently discovered heteroclinic connection between pairs of unstable periodic orbits (one around the L_1 and the other around L_2) implies a complicated dynamics for comets in a certain energy range. Furthermore, the stable and unstable invariant manifold `tubes' associated to libration point periodic orbits, of which the heteroclinic connections are a part, are phase space conduits transporting material to and from Jupiter and between the interior and exterior of Jupiter's orbit.

  11. [Establishment of Reference Value of Hs-cTnT in Sichuan Region and Its Diagnostic Value in Patients with Chest Pain].

    PubMed

    Guo, Ying; Du, Xiang-Yang; Huang, Hua-Lan; Wang, Wei-Qing; Nie, Xin; Li, Gui-Xing

    2017-11-01

    To establish the reference value of high sensitive cardiac troponin T (hs-cTnT) and the efficiency of reference value in the diagnosis of chest pain. Volunteers from eight independent communities in Chengdu,Sichuan were selected with detailed records of physical examination,electrocardiogram,ultrasound examination. The level of hs-cTnT for healthy volunteers was tested to determine ninety-ninth percentile references according to sex and ages. 2 249 patients with chest pain in the emergency department of Western China Hospital from July 2009 to July 2014 were enrolled to measure the efficiency of reference value for diagnosing acute myocardial infarction (AMI). There were 1 305 volunteers included finally. Among them,the mean hs-cTnT level of male was 4.3 (3.2-5.9) ng/L,which was significantly higher than that of female 3.0 (3.0-3.1) ng/L ( P <0.01) . The correlation coefficient between age and hs-cTnT level was 0.43 (male) and 0.29 (female),and the P -value was less than 0.01. The 99th percentile values of male were 10.8 ng/L,15.4 ng/L and 19.7 ng/L for <45 yr.,45-<60 yr. and ≥60 yr.,respectively. Those values of female were 4.6 ng/L,8.9 ng/L,18.8 ng/L,respectively. There was no difference in sensitivity and specificity between the value we figured out and manufactures provided (14.0 ng/L) for those<60 yr.. For the patients ≥60 yr.,the sensitivity and negative predictive value did not show diversity ( P >0.05) but the specificity and positive predictive value showed significant difference (male: 0.67 vs. 0.56 and 0.83 vs. 0.79, P <0.05;female:0.75 vs. 0.68 and 0.74 vs. 0.69, P <0.05). We recommends that the ninety-ninth percentile reference value of patients<60 yr. should be 14.0 ng/L,while 20.0 ng/L for those patients≥60 yr.

  12. Serum TSH reference interval in healthy Finnish adults using the Abbott Architect 2000i Analyzer.

    PubMed

    Schalin-Jäntti, Camilla; Tanner, Pirjo; Välimäki, Matti J; Hämäläinen, Esa

    2011-07-01

    Current serum TSH reference intervals have been criticized as they were established from unselected background populations. A special concern is that the upper limit, which defines subclinical hypothyroidism, is too high. The objective was to redefine the TSH reference interval in the adult Finnish population. The current reference interval for the widely used Abbott Architect method in Finland is 0.4-4.0 mU/L. Serum TSH and free T4 concentrations were derived from 606 healthy, non-pregnant, 18-91-year-old Finns from the Nordic Reference Interval Project (NORIP) and the possible effects of age, sex and thyroid peroxidase antibody (TPOAb) status were evaluated. After excluding TPOAb-positive subjects and outliers, a reference population of 511 subjects was obtained. In the reference population, no statistically significant gender- or age-specific differences in mean TSH (1.55 ± 3.30 mU/L) or TSH reference intervals were observed. The new reference interval was 0.5-3.6 mU/L (2.5th-97.5th percentiles). The current upper TSH reference limit is 10% too high. A TSH > 3.6 mU/L, confirmed with a repeat TSH sampling, may indicate subclinical hypothyroidism. Differences in ethnicity, regional iodine-intake and analytical methods underline the need for redefining the TSH reference interval in central laboratories in different countries.

  13. Dynamic recrystallization in friction surfaced austenitic stainless steel coatings

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Puli, Ramesh, E-mail: rameshpuli2000@gmail.com; Janaki Ram, G.D.

    2012-12-15

    Friction surfacing involves complex thermo-mechanical phenomena. In this study, the nature of dynamic recrystallization in friction surfaced austenitic stainless steel AISI 316L coatings was investigated using electron backscattered diffraction and transmission electron microscopy. The results show that the alloy 316L undergoes discontinuous dynamic recrystallization under conditions of moderate Zener-Hollomon parameter during friction surfacing. - Highlights: Black-Right-Pointing-Pointer Dynamic recrystallization in alloy 316L friction surfaced coatings is examined. Black-Right-Pointing-Pointer Friction surfacing leads to discontinuous dynamic recrystallization in alloy 316L. Black-Right-Pointing-Pointer Strain rates in friction surfacing exceed 400 s{sup -1}. Black-Right-Pointing-Pointer Estimated grain size matches well with experimental observations in 316L coatings.

  14. [Significance of 2-hour blood glucose after standardized steamed bread meal in diabetic screening].

    PubMed

    Liu, Yongquan; Tian, Hui; Fang, Fusheng; Xiao, Haiying; Lu, Yanhui; Shao, Yinghong; Li, Chunlin

    2014-05-13

    To explore the significance of 2-hour blood glucose after standardized steamed bread meal (SB-2 hBG) in diabetic screening. A retrospective study was conducted for diabetic screening data of annual check-up at PLA General Hospital from May 1996 to June 2002. And 100 g standardized steamed bread meal test was performed for non-diabetic subjects. Those subjects with SB-2 h BG ≥ 7.2 mmol/L underwent a 75 g oral glucose tolerance test (OGTT) within 2 weeks to determine whether the diagnosis of diabetes mellitus (DM) could be established (WHO, 1985, 1999, Diagnostic Criteria for Diabetes). By extracting the data for 7 consecutive years, we analyzed the significance and the cut-off point of SB-2 hBG in the diagnosis of DM and investigated the changes of blood glucose curves in different glucose tolerance status after different glucose loading tests. A total of 3 343 subjects with complete information were recruited. There were 3 101 males and 242 females with an age range of 40-94 years. According to the results of OGTT, 429 (12.8%) subjects were diagnosed as DM, 1 405 (42.1%) were diagnosed as impaired glucose regulation (IGR) and 1 509(45.1%) had normal glucose tolerance (NGT).With a deterioration of glucose tolerance status, the difference between SB-2 hBG and OGTT-2 hBG increased gradually in 3 group (P < 0.01), namely the NGT group 1.7 (0.8-2.8) mmol/L, IGR group -0.4 (-1.2-0.6) mmol/L, DM group -2.7(-3.8-1.1) mmol/L. The cut-off points of FBG for the diagnosis of IGR and DM were 5.3 (sensitivity of 46.2%, specificity of 68.5%) and 5.6 (sensitivity of 57.4%, specificity of 76.4%) mmol/L respectively. The cut-off points of SB-2 h BG were 8.2 mmol/L for the diagnosis of IGR (sensitivity of 63.8%, specificity of 59.9%) and 9.2 mmol/L for the diagnosis of DM (sensitivity of 66.4%, specificity of 76.4%).If the cut-off point of SB-2 h BG was set at 7.2 mmol/L, the diagnostic specificity became quite low.However, at 11.1 mmol/L, the sensitivity was 31.5% and the specificity 95.7% for the diagnosis of DM. The coincidences of cut-off points of FBG and SB-2 hBG for the diagnosis of IGR and DM were equal (P > 0.05).When the cut-off point of SB-2 h BG was set at 7.8 mmol/L, the sensitivity was 77.4% and the specificity 41.8% for the diagnosis of IGR. And it was much better than FBG at 5.6 mmol/L (P < 0.01). With a deterioration of glucose tolerance, the difference between SB-2 hBG and OGTT-2 hBG increases gradually. Compared to the diagnostic criteria of OGTT, the optimal cut-off points for the diagnosis of IGR and DM were 5.3 vs 5.6 mmol/L for FBG and 8.2 vs 9.2 mmol/L for SB-2 hBG respectively.For diabetic screening in middle-aged and elders, the cut-off points of FBG at 5.3 mmol/L and SB-2 hBG at 7.8 mmol/L are indicators for further OGTT.

  15. CTD Observations on the North Brazil Shelf During A Multidisciplinary Amazon Shelf SEDiment Study (AMASSEDS)

    DTIC Science & Technology

    1992-06-01

    Milligan, H. Morganne, W. Moore, M. Veiga , G. Negreiros, A. Ogston, R. Portugal, H. Oliveira, R. Paiva, R. Pope, A. Rodrigues, K. Ruttenberg, J. Sarmento...34fCL -12 f ~l -12 1 -16 -20 -20 -2 -L L L - 241 L L0 4 B 12 16 20 24 0 4 8 U2 16 20 24 Time (hr) Time (hr) 57 i i i I 27 tI 6I fL * t *. 2 * . 1 I...Guard R&D Center University of Miami Aver Point Gu4600 Rickenbacker Causewayvery Point Miami, FL 33149 Groton, CT 06340I Maury Oceanographic Library

  16. Age specific serum anti-Müllerian hormone levels in 1,298 Korean women with regular menstruation

    PubMed Central

    Yoo, Ji Hee; Cha, Sun Wha; Park, Chan Woo; Yang, Kwang Moon; Song, In Ok; Koong, Mi Kyoung; Kang, Inn Soo

    2011-01-01

    Objective To determine the age specific serum anti-Müllerian hormone (AMH) reference values in Korean women with regular menstruation. Methods Between May, 2010 and January, 2011, the serum AMH levels were evaluated in a total of 1,298 women who have regular menstrual cycles aged between 20 and 50 years. Women were classified into 6 categories by age: 20-31 years, 32-34 years, 35-37 years, 38-40 years, 41-43 years, above 43 years. Measurement of serum AMH was measured by commercial enzyme-linked immunoassay. Results The serum AMH levels correlated negatively with age. The median AMH level of each age group was 4.20 ng/mL, 3.70 ng/mL, 2.60 ng/mL, 1.50 ng/mL, 1.30 ng/mL, and 0.60 ng/mL, respectively. The AMH values in the lower 5th percentile of each age group were 1.19 ng/mL, 0.60 ng/mL, 0.42 ng/mL, 0.27 ng/mL, 0.14 ng/mL, and 0.10 ng/mL, respectively. Conclusion This study determined reference values of serum AMH in Korean women with regular menstruation. These values can be applied to clinical evaluation and treatment of infertile women. PMID:22384425

  17. The use of HeartQoL in patients with coronary heart disease: Association with risk factors and European reference values. The EUROASPIRE IV study of the European Society of Cardiology.

    PubMed

    De Smedt, Delphine; Clays, Els; Höfer, Stefan; Oldridge, Neil; Kotseva, Kornelia; Maggioni, Aldo Pietro; Pogosova, Nana; Dolzhenko, Maryna; De Bacquer, Dirk

    2016-07-01

    HeartQoL is a recently developed core health-related quality of life instrument for patients with coronary heart disease. The current study aims to investigate its association with patients' coronary risk profile and to provide reference values for patients with coronary heart disease across Europe. Analyses are based on the EUROASPIRE IV (EUROpean Action on Secondary and Primary prevention through Intervention to Reduce Events) cross-sectional survey. Patients with a diagnosis of coronary heart disease were examined and interviewed six months to three years after their coronary event. The HeartQoL questionnaire was completed by 7261 coronary heart disease patients. Reference values were calculated and the association with the coronary risk profile was assessed. Significantly worse outcomes were observed in higher-risk patient groups. Both metabolic and behavioural risk factors were associated with worse HeartQoL outcomes. Further, the HeartQoL scores decreased as the number of risk factors increased. The mean global reference values in males were 2.27 ± 0.65 (<60 years), 2.30 ± 0.61 (between 60 and 69 years) and 2.19 ± 0.64 (≥70 years). Likewise, in females, the respective global HeartQoL reference values were 2.02 ± 0.67, 2.01 ± 0.66 and 1.83 ± 0.70. The ceiling effect in males was 11.4%, 10.4% and 7.4% for the three age classes respectively, whereas in females the ceiling effect was 5.2%, 3.5% and 1.9%, respectively. HeartQoL scores were associated with patients' coronary risk profile. The reference values may help other researchers to interpret HeartQoL scores. Further research should focus on the minimal important difference needed to evaluate the effect of therapies and lifestyle changes. © The European Society of Cardiology 2016.

  18. Diagnostic accuracy of a five-point Likert scoring system for magnetic resonance imaging (MRI) evaluated according to results of MRI/ultrasonography image-fusion targeted biopsy of the prostate.

    PubMed

    Shin, Toshitaka; Smyth, Thomas B; Ukimura, Osamu; Ahmadi, Nariman; de Castro Abreu, Andre Luis; Ohe, Chisato; Oishi, Masakatsu; Mimata, Hiromitsu; Gill, Inderbir S

    2018-01-01

    To evaluate the accuracy of a magnetic resonance imaging (MRI)-based Likert scoring system in the detection of clinically significant prostate cancer (CSPC), using MRI/ultrasonography (US) image-fusion targeted biopsy (FTB) as a reference standard. We retrospectively reviewed 1218 MRI-detected lesions in 629 patients who underwent subsequent MRI/US FTB between October 2012 and August 2015. 3-Tesla MRI was independently reported by one of eight radiologists with varying levels of experience and scored on a five-point Likert scale. All lesions with Likert scores 1-5 were prospectively defined as targets for MRI/US FTB. CSPC was defined as Gleason score ≥7. The median patient age was 64 years, PSA level 6.97 ng/mL and estimated prostate volume 52.2 mL. Of 1218 lesions, 48% (n = 581) were rated as Likert 1-2, 35% (n = 428) were Likert 3 and 17% (n = 209) were Likert 4-5. For Likert scores 1-5, the overall cancer detection rates were 12%, 13%, 22%, 50% and 59%, respectively, and the CSPC detection rates were 4%, 4%, 12%, 33% and 48%, respectively. Grading using the five-point scale showed strong positive correlation with overall cancer detection rate (r = 0.949, P = 0.05) and CSPC detection rate (r = 0.944, P = 0.05). By comparison, in Likert 4-5 lesions, significant differences were noted in overall cancer detection rate (63% vs 35%; P = 0.001) and CSPC detection rate (47% vs 29%; P = 0.027) for the more experienced vs the less experienced radiologists. The detection rates of overall cancer and CSPC strongly correlated with the five-point grading of the Likert scale. Among radiologists with different levels of experience, there were significant differences in these cancer detection rates. © 2017 The Authors BJU International © 2017 BJU International Published by John Wiley & Sons Ltd.

  19. Local sensitivity of per-recruit fishing mortality reference points.

    PubMed

    Cadigan, N G; Wang, S

    2016-12-01

    We study the sensitivity of fishery management per-recruit harvest rates which may be part of a quantitative harvest strategy designed to achieve some objective for catch or population size. We use a local influence sensitivity analysis to derive equations that describe how these reference harvest rates are affected by perturbations to productivity processes. These equations give a basic theoretical understanding of sensitivity that can be used to predict what the likely impacts of future changes in productivity will be. Our results indicate that per-recruit reference harvest rates are more sensitive to perturbations when the equilibrium catch or population size per recruit, as functions of the harvest rate, have less curvature near the reference point. Overall our results suggest that per recruit reference points will, with some exceptions, usually increase if (1) growth rates increase, (2) natural mortality rates increase, or (3) fishery selectivity increases to an older age.

  20. Relative bioavailability of two 5-mg montelukast sodium chewable tablets: a single dose, randomized, open-label, 2-period crossover comparison in healthy korean adult male volunteers.

    PubMed

    Kim, H T; Song, Y-K; Lee, S D; Park, Y; Kim, C-K

    2012-03-01

    Montelukast sodium, cysteinyl leukotriene receptor 1 specific antagonist, has been marketed in Korea for the treatment of bronchial asthma and allergic rhinitis. The aim of this study was to compare the pharmacokinetics and relative bioavailability of a test and reference formulation of montelukast 5-mg chewable tablets in healthy Korean male volunteers to meet KFDA regulatory criteria for marketing of the new generic formulation. This study was designed as a single-dose, 2-treatment, and 2-period crossover trial with 32 healthy volunteers. Each subject was randomly assigned to receive the test (Dong-Kook Montelukast Sodium Chewable Tablet 5 mg®) or reference (Singulair Chewable Tablet 5 mg®) formulation. The tablet was chewed 20 times, and then swallowed with 240 mL of water. Plasma concentrations of montelukast up to 24 h after the dose were determined using a validated UPLC-MS/MS method, and the bioequivalence between the 2 formulations was assessed by statistical analysis of mean ratios of log-transformed AUC0-24 h and Cmax. No period or sequence effects were detected. The AUC0-24 h was 1 835 ng·h/mL for the test formulation, and 1 930 ng·h/mL for the reference formulation. The respective values of AUC0-∞ were 1 917 and 2 015 ng·h/mL. The Cmax of the test and reference products (247 and 283 ng/mL, respectively) reached at 2.25 and 2.72 h, respectively. Then, they gradually decreased with the mean terminal t1/2 of 5.25 and 5.30 h for the test and reference products, respectively. The 90% CIs for the ratio of log-transformed AUC0-24 h and Cmax for the test and reference formulations were 0.92-0.99 and 0.83-0.91, respectively. No adverse events were reported in this study. This single dose study found that the test and reference products met the regulatory criteria for bioequivalence in these fasting healthy Korean male volunteers. © Georg Thieme Verlag KG Stuttgart · New York.

  1. Pharmacokinetics and bioavailability of single dose ibuprofen and pseudoephedrine alone or in combination: a randomized three-period, cross-over trial in healthy Indian volunteers

    PubMed Central

    Kale, Prashant

    2014-01-01

    Objective: To compare the bioavailability of single dose ibuprofen 200 mg and pseudoephedrine hydrochloride 30 mg administered alone or in combination as an oral suspension. Methods: This was a single-center, randomized, single-dose, open-label, 3-period, crossover study. After an overnight fast (≥10 h), 18 healthy male subjects received either ibuprofen 200 mg (reference-A), pseudoephedrine 30 mg (reference-B) or the combination (test-C) as a suspension, on 3 separate visits, with blood sampling up to 36-h post-dose. The primary pharmacokinetic parameters, maximum plasma concentration (Cmax) and area under the plasma concentration–time curve (AUC) from time zero to last measurable concentration (AUC0−t) and extrapolated to infinity (AUC0−∞) were compared by an analysis of variance using log-transformed data. Bioequivalence was concluded if the 90% confidence intervals (CIs) of the adjusted geometric mean (gMean) ratios for Cmax and AUC were within the predetermined range of 80–125%, in accordance with regulatory requirements. Results: For the test formulation, the ibuprofen gMean Cmax was 17.0 μg/mL (vs. 18.1 μg/mL for reference-A), AUC0−t was 57.1 (vs. 60.0 μg·h/mL), and AUC0−∞ was 59.9 μg·h/mL (vs. 63.1 μg·h/mL). The 90% CIs for the ratio (test/reference-A) were 81.0–108.1% for Cmax, 91.5–98.4% for AUC0−t and 91.6–97.9% for AUC0−∞. For pseudoephedrine, the gMean Cmax for the test formulation was 97.2 ng/mL (vs. 98.5 ng/mL for reference-B), AUC0−t was 878.4 (vs. 842.8 ng·h/mL) and AUC0−∞ was 907.8 ng·h/mL (vs. 868.3 ng·h/mL). The 90% CIs for the ratio (test/reference-B) were 92.4–106.9% for Cmax, 97.7–111.0% for AUC0−t and 97.9–111.3% for AUC0−∞. All treatments were well tolerated. Conclusion: This oral suspension containing ibuprofen and pseudoephedrine combined in a new formulation met the regulatory criterion for bioequivalence compared with oral suspensions containing the individual components. PMID:24847268

  2. Comprehensive evaluation of candidate reference genes for gene expression studies in Lysiphlebia japonica (Hymenoptera: Aphidiidae) using RT-qPCR.

    PubMed

    Gao, Xue-Ke; Zhang, Shuai; Luo, Jun-Yu; Wang, Chun-Yi; Lü, Li-Min; Zhang, Li-Juan; Zhu, Xiang-Zhen; Wang, Li; Lu, Hui; Cui, Jin-Jie

    2017-12-30

    Lysiphlebia japonica (Ashmead) is a predominant parasitoid of cotton-melon aphids in the fields of northern China with a proven ability to effectively control cotton aphid populations in early summer. For accurate normalization of gene expression in L. japonica using quantitative reverse transcriptase-polymerase chain reaction (RT-qPCR), reference genes with stable gene expression patterns are essential. However, no appropriate reference genes is L. japonica have been investigated to date. In the present study, 12 selected housekeeping genes from L. japonica were cloned. We evaluated the stability of these genes under various experimental treatments by RT-qPCR using four independent (geNorm, NormFinder, BestKeeper and Delta Ct) and one comparative (RefFinder) algorithm. We identified genes showing the most stable levels of expression: DIMT, 18S rRNA, and RPL13 during different stages; AK, RPL13, and TBP among sexes; EF1A, PPI, and RPL27 in different tissues, and EF1A, RPL13, and PPI in adults fed on different diets. Moreover, the expression profile of a target gene (odorant receptor 1, OR1) studied during the developmental stages confirms the reliability of the chosen selected reference genes. This study provides for the first time a comprehensive list of suitable reference genes for gene expression studies in L. japonica and will benefit subsequent genomics and functional genomics research on this natural enemy. Copyright © 2017. Published by Elsevier B.V.

  3. Maternal Exposure to Bisphenol-A and Fetal Growth Restriction: A Case-Referent Study

    PubMed Central

    Burstyn, Igor; Martin, Jonathan W.; Beesoon, Sanjay; Bamforth, Fiona; Li, Qiaozhi; Yasui, Yutaka; Cherry, Nicola M.

    2013-01-01

    We conducted a case-referent study of the effect of exposure to bisphenol-A on fetal growth in utero in full-term, live-born singletons in Alberta, Canada. Newborns <10 percentile of expected weight for gestational age and sex were individually matched on sex, maternal smoking and maternal age to referents with weight appropriate to gestational age. Exposure of the fetus to bisphenol-A was estimated from maternal serum collected at 15–16 weeks of gestation. We pooled sera across subjects for exposure assessment, stratified on case-referent status and sex. Individual 1:1 matching was maintained in assembling 69 case and 69 referent pools created from 550 case-referent pairs. Matched pools had an equal number of aliquots from individual women. We used an analytical strategy conditioning on matched set and total pool-level values of covariates to estimate individual-level effects. Pools of cases and referents had identical geometric mean bisphenol-A concentrations (0.5 ng/mL) and similar geometric standard deviations (2.3–2.5). Mean difference in concentration between matched pools was 0 ng/mL, standard deviation: 1 ng/mL. Stratification by sex and control for confounding did not suggest bisphenol-A increased fetal growth restriction. Our analysis does not provide evidence to support the hypothesis that bisphenol-A contributes to fetal growth restriction in full-term singletons. PMID:24336026

  4. Applying Strategic Visualization(Registered Trademark) to Lunar and Planetary Mission Design

    NASA Technical Reports Server (NTRS)

    Frassanito, John R.; Cooke, D. R.

    2002-01-01

    NASA teams, such as the NASA Exploration Team (NEXT), utilize advanced computational visualization processes to develop mission designs and architectures for lunar and planetary missions. One such process, Strategic Visualization (trademark), is a tool used extensively to help mission designers visualize various design alternatives and present them to other participants of their team. The participants, which may include NASA, industry, and the academic community, are distributed within a virtual network. Consequently, computer animation and other digital techniques provide an efficient means to communicate top-level technical information among team members. Today,Strategic Visualization(trademark) is used extensively both in the mission design process within the technical community, and to communicate the value of space exploration to the general public. Movies and digital images have been generated and shown on nationally broadcast television and the Internet, as well as in magazines and digital media. In our presentation will show excerpts of a computer-generated animation depicting the reference Earth/Moon L1 Libration Point Gateway architecture. The Gateway serves as a staging corridor for human expeditions to the lunar poles and other surface locations. Also shown are crew transfer systems and current reference lunar excursion vehicles as well as the Human and robotic construction of an inflatable telescope array for deployment to the Sun/Earth Libration Point.

  5. The Use of L1 Reading Strategies in L2 Reading: Effects of L1 Orthographic Structures in L2 Phonological Recoding Strategies.

    ERIC Educational Resources Information Center

    Koda, Keiko

    1990-01-01

    An investigation of native language influence on second-language (English) reading processed indicated that, when essential phonological information was inaccessible, Arabic and Spanish phonographic readers were seriously impaired, although Japanese morphographic readers were not affected. (83 references) (Author/CB)

  6. Real-time processing of gender-marked articles by native and non-native Spanish speakers

    PubMed Central

    Lew-Williams, Casey; Fernald, Anne

    2010-01-01

    Three experiments using online processing measures explored whether native and non-native Spanish-speaking adults use gender-marked articles to identify referents of target nouns more rapidly, as shown previously with 3-year-old children learning Spanish as L1 (Lew-Williams & Fernald, 2007). In Experiment 1, participants viewed familiar objects with names of either the same or different grammatical gender while listening to Spanish sentences referring to one object. L1 adults, like L1 children, oriented to the target more rapidly on different-gender trials, when the article was informative about noun identity; however, L2 adults did not. Experiments 2 and 3 controlled for frequency of exposure to article-noun pairs by using novel nouns. L2 adults could not exploit gender information when different article-noun pairs were used in teaching and testing. Experience-related factors may influence how L1 adults and children and L2 adults—who learned Spanish at different ages and in different settings—use grammatical gender in realtime processing. PMID:21076648

  7. SU-F-T-113: Inherent Functional Dependence of Spinal Cord Doses of Variable Irradiated Volumes in Spine SBRT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ma, L; Braunstein, S; Chiu, J

    2016-06-15

    Purpose: Spinal cord tolerance for SBRT has been recommended for the maximum point dose level or at irradiated volumes such as 0.35 mL or 10% of contoured volumes. In this study, we investigated an inherent functional relationship that associates these dose surrogates for irradiated spinal cord volumes of up to 3.0 mL. Methods: A hidden variable termed as Effective Dose Radius (EDR) was formulated based on a dose fall-off model to correlate dose at irradiated spinal cord volumes ranging from 0 mL (point maximum) to 3.0 mL. A cohort of 15 spine SBRT cases was randomly selected to derive anmore » EDR-parameterized formula. The mean prescription dose for the studied cases was 21.0±8.0 Gy (range, 10–40Gy) delivered in 3±1 fractions with target volumes of 39.1 ± 70.6 mL. Linear regression and variance analysis were performed for the fitting parameters of variable EDR values. Results: No direct correlation was found between the dose at maximum point and doses at variable spinal cord volumes. For example, Pearson R{sup 2} = 0.643 and R{sup 2}= 0.491 were obtained when correlating the point maximum dose with the spinal cord dose at 1 mL and 3 mL, respectively. However, near perfect correlation (R{sup 2} ≥0.99) was obtained when corresponding parameterized EDRs. Specifically, Pearson R{sup 2}= 0.996 and R{sup 2} = 0.990 were obtained when correlating EDR (maximum point dose) with EDR (dose at 1 mL) and EDR(dose at 3 mL), respectively. As a result, high confidence level look-up tables were established to correlate spinal cord doses at the maximum point to any finite irradiated volumes. Conclusion: An inherent functional relationship was demonstrated for spine SBRT. Such a relationship unifies dose surrogates at variable cord volumes and proves that a single dose surrogate (e.g. point maximum dose) is mathematically sufficient in constraining the overall spinal cord dose tolerance for SBRT.« less

  8. Hematologic and plasma biochemistry reference intervals of healthy adult barn owls (Tyto alba).

    PubMed

    Szabo, Zoltan; Klein, Akos; Jakab, Csaba

    2014-06-01

    Hematologic and plasma biochemistry parameters of barn owls (Tyto alba) were studied in collaboration by the Exotic Division of the Faculty of Veterinary Science of the Szent Istvan University and the Eötvös Loránd University, both in Budapest, Hungary. Blood samples were taken from a total of 42 adult barn owls kept in zoos and bird repatriation stations. The following quantitative and qualitative hematologic values were determined: packed cell volume, 46.2 +/- 4%; hemoglobin concentration, 107 +/- 15 g/L; red blood cell count, 3.2 +/- 0.4 x 10(12)/L; white blood cell count, 13.7 +/- 2.7 x 10(9)/L; heterophils, 56.5 +/- 11.5% (7.8 +/- 2 x 10(9)/L); lymphocytes, 40.3 +/- 10.9% (5.5 +/- 1.9 x 10(9)/L); monocytes, 1.8 +/- 2.1% (0.3 +/- 0.3 x 10(9)/ L); eosinophils, 1 +/- 1% (0.1 +/- 0.1 x 10(9)/L); and basophils, 0.6 +/- 0.5% (0.1 +/- 0.1 x 10(9)/L). The following plasma biochemistry values also were determined: aspartate aminotransferase, 272 +/- 43 U/L; L-gamma-glutamyltransferase, 9.5 +/- 4.7 U/L; lipase, 31.7 +/- 11.1 U/L; creatine kinase, 2228 +/- 578 U/L; lactate dehydrogenase, 1702 +/- 475 U/L; alkaline phosphatase, 358 +/- 197 U/L; amylase, 563 +/- 114 U/L; glutamate dehydrogenase, 7.5 +/- 2.5 U/L; total protein, 30.6 +/- 5.3 g/L; uric acid, 428 +/- 102 micromol/L; and bile acids, 43 +/- 18 micromol/L. These results provide reliable reference values for the clinical interpretation of hematologic and plasma biochemistry results for the species.

  9. Doxycycline concentration over time after storage in a compounded veterinary preparation.

    PubMed

    Papich, Mark G; Davidson, Gigi S; Fortier, Lisa A

    2013-06-15

    To determine the concentration of doxycycline compounded from doxycycline hyclate tablets into liquid formulations for oral administration in veterinary species and stored for 28 days. Evaluation study. Doxycycline hyclate tablets (100 mg) crushed and mixed with a 50:50 mixture of syrup and suspension vehicles for oral administration to produce 3 batches each of 2 doxycycline formulations: 33.3 and 166.7 mg/mL. Formulations were stored, protected from light, at room temperature (22° to 26°C [71.6° to 78.8°F]) and at a controlled cold temperature (refrigerated 2° to 8°C [35.6° to 46.4°F]). Doxycycline was extracted from the formulations, and concentration was measured by high-pressure liquid chromatography on days 0 (date of preparation), 1, 4, 7, 14, 21, and 28. Concentrations were compared with those of a US Pharmacopeial Convention reference standard. Formulation quality at each point was also assessed through color change, formulation consistency, and suspension uniformity. On days 0, 1, 4, and 7, the concentration of each formulation was within 90% to 110% of the reference standard (range, 93% to 109%), which was deemed acceptable. However, doxycycline concentrations had decreased dramatically by day 14 and remained low for the duration of the study period. Doxycycline concentrations on days 14, 21, and 28 were all < 20% (range, 14% to 18%) of the reference standard, and the quality of the formulations decreased as well. No effect of storage temperatures on doxycycline concentration was identified. The concentration of doxycycline, compounded from commercial tablets in the vehicles evaluated to yield doses of 33.3 and 166.7 mg/mL, cannot be assured beyond 7 days.

  10. Fatigue life assessment of 316L stainless steel and DIN-1.4914 martensitic steel before and after TEXTOR exposure

    NASA Astrophysics Data System (ADS)

    Shakib, J. I.; Ullmaier, H.; Little, E. A.; Schmitz, W.; Faulkner, R. G.; Chung, T. E.

    1992-09-01

    The effects of plasma exposure in the TEXTOR tokomak on elevated temperature fatigue lifetime and failure micromechanisms of 316L austenitic stainless steel and DIN 1.4914 martensitic steel (NET reference heats) have been evaluated. Fatigue tests were carried out in vacuum in the temperature range 150°-450°C and compared with data from reference specimens.Plasma-induced surface modifications lead to significant deterioration in fatigue life of 316L steel, whereas the lifetime of 1.4914 steel is unaffected. Fatigue in the 1.4914 steel is surface-initiated only at high stresses. At low stress amplitudes internal fatigue initiation at inclusions was observed.

  11. Multicentre physiological reference intervals for serum concentrations of immunoglobulins A, G and M, complement C3c and C4 measured with Tina-Quant reagents systems.

    PubMed

    Fuentes-Arderiu, Xavier; Alonso-Gregorio, Eduardo; Alvarez-Funes, Virtudes; Ambrós-Marigómez, Carmen; Coca-Fábregas, Lluís; Cruz-Placer, Marta; Díaz-Fernández, Julián; Pinel-Julián, María Pilar; Gutiérrez-Cecchini, Beatriz; Herrero-Bernal, Pilar; Sempere-Alcocer, Marcos; García-Caballero, Francisca; Del Mar Larrea-Ortiz-Quintana, María; La-Torre-Marcellán, Pedro; Del Señor López-Vélez, María; Mar-Medina, Carmen; Martín-Oncina, Javier; Rodríguez-Hernández, María Victoria; Romero-Sotomayor, María Victoria; Serrano-López, Cándido; Sicilia-Enríquez-de-Salamanca, Adolfo; Velasco-Romero, Ana María; Juvé-Cuxart, Santiago

    2007-01-01

    Clinical laboratories seeking accreditation for compliance with ISO 15189:2003 need to demonstrate that the physiological reference intervals communicated to all users of the laboratory service are appropriate for the patient population served and for the measurement systems used. In the case of immunological quantities, few articles have been published in peer-reviewed journals. A total of 21 clinical laboratories in different regions of Spain collaborated in identifying reference individuals and determining adult reference intervals for some immunological quantities measured using RD/Hitachi Modular Analytics analysers and Tina-Quant reagent systems. These immunological quantities are the mass concentrations of immunoglobulin A, immunoglobulin G, immunoglobulin M, complement C3c and complement C4 in serum. All the logistic work was carried out in co-operation with the supplier of the reagents and analysers (Roche Diagnostics España, S.L., Sant Cugat del Vallès, Catalonia, Spain). From the set of reference values obtained by each laboratory, multicentre reference limits were estimated non-parametrically. The reference intervals estimated in this study for concentrations of serum components under consideration are: complement C3c, 0.62-1.64 g/L for women and men; complement C4, 0.14-0.72 g/L for women and men; immunoglobulin A, 0.89-4.80 g/L for women and men; immunoglobulin G, 6.5-14.3 g/L for women and men; and immunoglobulin M, 0.48-3.38 g/L for women and 0.41-2.46 g/L for men.

  12. Optimization of chemometric approaches for the extraction of isorhamnetin-3-O-rutinoside from Calendula officinalis L.

    PubMed

    Moraes, Maria Lourdes Leite; da Silva, Heron Dominguez Torres; Blanes, Lucas; Doble, Philip; Tavares, Marina Franco Maggi

    2016-06-05

    The application of Design of Experiments (DoE) to the determination of optimum conditions for an extraction process relies on the correct selection of mathematical models. The linear model is the one typically used; however, in some cases it does not always have superior performance, ignoring the real nature of the data and its appropriate descriptive model. In order to evaluate the extraction efficiency of isorhamnetin-3-O-rutinoside from flowers of Calendula officinalis L. a multivariate factorial analysis was used. Simulations were conducted using linear, quadratic, full cubic and special cubic models. A Simplex-Centroid design was chosen as it delivered greater precision with only minor errors versus other models tested. Analyses were performed by capillary zone electrophoresis using sodium tetraborate buffer (40mmolL(-1), pH 9.4) containing 10% methanol. The detection was linear over a range of 8.0-50.0mgL(-1) (r(2)=0.996), and the limits of detection (LOD) and quantification (LOQ) for isorhamnetin-3-O-rutinoside were 3.44mgL(-1) and 11.47mgL(-1), respectively. The full cubic model showed the best extraction results, with an error of 3.40% compared to analysis of variance, and a determination coefficient of 0.974. The difference between the responses at the reference point, calculated by the model, and the experimental response, varies around 2.72% for full cubic model. Comparison of the four models showed the full cubic model was the most appropriate one, allowing greater efficiency in the extraction of isorhamnetin-3-O-rutinoside. Selection of the model made it possible to obtain a 60% increase in sensitivity compared to the linear model. Copyright © 2016. Published by Elsevier B.V.

  13. Effects of thromboprophylactic doses of apixaban and rivaroxaban on coagulation and thrombin generation in association with total hip replacement.

    PubMed

    Helin, Tuukka A; Virtanen, Lauri; Manninen, Mikko; Leskinen, Jarkko; Leppilahti, Juhana; Joutsi-Korhonen, Lotta; Lassila, Riitta

    2017-05-01

    Factor Xa inhibitors (FXaI) apixaban and rivaroxaban are used for thromboprophylaxis after major elective orthopaedic surgery. Because few patient sample studies exist, we postoperatively assessed patients undergoing unilateral total hip arthroplasty, including 22 treated with apixaban (2.5 mg BID) and 20 treated with rivaroxaban (10 mg OD). We collected blood samples before and 3 h after drug intake at 4 time points, preoperatively, as well as on day 1, week 1 (day 2-8) and day 28 post-operation. APTT and PT were immediately analysed. Calibrated anti-FXa activity, Russel's Viper Venom Time (RVVT) and thrombin generation (TG; Calibrated Automated Thrombogram ® ) captured the effects of FXaI on coagulation and TG. APTT and PT remained within the reference interval throughout, and did not correlate with FXaI levels (PT R 2  = 0.44, APTT R 2  = 0.07). Mean apixaban concentration at the peak varied by eightfold (19-153 ng/mL), but rivaroxaban only by 1.5-fold (111-183 ng/mL). Rivaroxaban, but not apixaban prolonged RVVT at peak levels. Both FXaIs had a prolonged lag time of TG (p < 0.001). Rivaroxaban decreased ETP peak at all time points and reached a minimum at day 28 (540 nM/min at rivaroxaban 184 ng/mL, p < 0.001), while rivaroxaban trough levels were low and ETP values normal. However, with apixaban, after an initial decrease, ETP did not differ between peak and trough levels until decreasing on day 28 at peak (990 nM/min at apixaban 112 ng/mL, p = 0.005). In conclusion, due to different dosing and pharmacology rivaroxaban and apixaban distinctly inhibited TG under postoperative conditions.

  14. Fontinalis antipyretica as a bioindicator of environmental conditions in freshwater ecosystem from Sava River watershed and Cerknişko Lake, Slovenia

    NASA Astrophysics Data System (ADS)

    Kanduč, Tjaša; Mechora, Špela; Stibilj, Vekoslava

    2014-05-01

    Polluted waters recharging from agriculture water systems into watersheds have influence on water quality and living habitat. Stable isotopes of carbon and nitrogen in combination with other minor and trace elements are often used to trace biogeochemical processes and contamination of water systems. The aim of the study was to assess state of environment with minor and trace elements and stable isotopes of C and N in selected Slovenian streams. Ten locations in Notranjska region, Slovenia, with different land use in the catchment (town, village, agricultural areas, farms, dairy farms), including reference point considered as non-polluted site, were sampled. Samples of water and aquatic moss F. antipyretica in Slovenian fresh waters were taken in all four seasons during years 2010 and 2012, but for stable isotope analyses of C and N only in three seasons during years 2010 and 2011. The water chemistry of investigated locations is dominated by hydrogen carbonate - calcium - magnesium, concentrations of nitrate seasonally range from 2.07 mg/l to 6.4 mg/l and at reference site does not exceed 1.3 mg/l. Total alkalinity of water at investigated locations ranges from 2.9 to 6.02 mM. The pH of investigated water range from 7.2 to 8.5, waters are saturated with oxygen (up to 134%) and conductivity ranges from 295 to 525 mikroS/cm, while at reference site conductivity is up to 180 mikroS/cm. The content of minor and trace elements in F. antipyretica ranged for Ni 4-38 mikrog/g, Zn 17-105 mikrog/g, Pb 2-28 mikrog/g, Cd 220-1953 ng/g, Cu 4-27 mikrog/g, Cr 4-49 mikrog/g, As 1-6 mikrog/g and Se 0.33-3.24 mikrog/g. The most polluted watershed was Pšata stream (agricultural areas, cattle farm) with highest values for Ni, Cr, Pb, Zn and As. The highest content of Se, was found in village (dairy farms) in Žerovniščica stream. The highest values were measured in February and October. Isotopic composition of dissolved inorganic carbon seasonally range from -13.3 to -8.1‰, and indicate waters dominated by degradation of organic matter and dissolution of carbonates. At the reference point average measured isotopic composition of dissolved inorganic carbon value is -2.7‰ which confirmed that this is a non-polluted site. Isotopic composition of carbon of F. antipyretica seasonally ranges from -45 to -32.9‰ and isotopic composition of nitrogen from -0.2‰ to 6.5‰, respectively. In comparison to C3 terrestrial plants F. antipyretica has more negative isotopic composition of carbon value, which is probably related with the difference in CO2 plant fixation and depends on isotopic composition of dissolved inorganic carbon in water, which is primarily controlled by geological composition and soil thickness in the watershed. Higher isotopic composition of nitrogen value found in F. antipyretica is related to agricultural activity in watershed, while at the reference site measured isotopic composition of nitrogen value is -4.1 ‰. From our study it is evident that isotopic composition of carbon and nitrogen is useful tracer of natural and anthropogenic inputs from terrestrial (fertilizing, sewage sludge) to water system.

  15. Definition of reference ranges for free T4, TSH, and thyroglobulin levels in healthy subjects of the Jaén Health District.

    PubMed

    Olmedo Carrillo, Pablo; Santiago Fernández, Piedad; García Fuentes, Eduardo; Ureña Fernández, Tomás; Gutiérrez Alcántara, Carmen; Sánchez-Malo, Carolina; Gassó Campos, Manuela; Martínez Ramírez, María José

    2017-10-01

    The treatment guidelines for thyroid dysfunction recommend defining reference ranges for thyroid hormones in each area through assessment of local population data considering the iodine nutritional status. The aim of this study was to define the reference ranges of free thyroxine (FT4), TSH, and thyroglobulin levels in a general population from Jaen, an area of southern Spain with an adequate iodine nutritional status, and whether they were associated with urinary iodine levels. A cross-sectional study was conducted in 1,003 subjects of the general population of the Jaen Health District. Levels of urinary iodine, FT4, TSH, thyroglobulin, and thyroid peroxidase (TPO) antibodies were measured according to age and sex. Median and mean urinary iodine levels were 110.59μg/L and 130.11μg/L respectively. Median TSH level was 1.83μIU/mL (p2.5=0.56μIU/mL, p97.5=4.66μIU/mL). Median FT4 level was 0.84ng/dL (p2.5=0.62ng/dL, p97.5=1.18ng/dL). TPO antibodies were detected in 5.7% of subjects. There was no correlation between urinary iodine levels and FT4, TSH or TPO antibodies. Subjects with positive TPO antibodies had higher TSH levels (3.34μIU/L versus 2.14μIU/mL, P=.001; odds ratio=2.42). Urinary iodine levels in Jaen are optimal according to World Health Organization standards. Reference ranges of FT4, TSH, and thyroglobulin do not differ from those reported in the literature and are no associated to urinary iodine levels. The prevalence of positive TPO antibodies was similar to that reported in other Spanish areas. Copyright © 2017 SEEN y SED. Publicado por Elsevier España, S.L.U. All rights reserved.

  16. USSR and Eastern Europe Scientific Abstracts, Chemistry. Number 49

    DTIC Science & Technology

    1976-11-04

    phosphorus tribromide with oxygen initia- tion leads to the synthesis of l-bromoalkane-2-phosphonous acid dibromides. References 8: 4 Russian, 4 Western. 1 ...are developed for synthesis of dialkylmethylphosphonates by nitration of ethoxyvinylphosphonates. References 21: 19 Russian, 2 Western. 1 / 1 USSR...spectroscopic data and reverse synthesis . Figures 2; References 3: 1 Russian, 2 Western. 1 / 1 28 USSR UDC 547.26� GOLOLOBOV, YU. G., BOLDESKUL, I

  17. Bioequivalence of generic lamotrigine 100-mg tablets in healthy Thai male volunteers: a randomized, single-dose, two-period, two-sequence crossover study.

    PubMed

    Srichaiya, Arunee; Longchoopol, Chaowanee; Oo-Puthinan, Sarawut; Sayasathid, Jarun; Sripalakit, Pattana; Viyoch, Jarupa

    2008-10-01

    Lamotrigine is an antiepileptic drug which has been used in the treatment of epilepsy and bipolar disorder. A search of the literature did not find previously published bioequivalence and pharmacokinetic evaluations of lamotrigine in healthy Thai male volunteers. The aim of this study was to compare the pharmacokinetic parameters between 2 brands of lamotrigine in healthy Thai male volunteers. A randomized, single-dose, 2-period, 2-sequence, crossover study design with a 2-week washout period was conducted in healthy Thai males. Subjects were randomized to receive either the test or reference formulation in the first period. All subjects were required to be nonsmokers and without a history of alcohol or drug abuse. Plasma samples were collected over a 120-hour period after 100-mg lamotrigine administration in each period. A validated high-performance liquid chromatography ultraviolet method was used to analyze lamotrigine concentration in plasma. Pharmacokinetic parameters were determined using a noncompartmental method. Bioequivalence between the test and reference products, as defined by the US Food and Drug Administration (FDA), is determined when the ratio for the 90% CIs of the difference in the means of the log-transformed AUC(0-t), AUC(0-infinity), and C(max) of the 2 products are within 0.80 and 1.25. Adverse events were determined by measuring vital signs after dosing. Subjects were also asked if they suffered from undesirable effects such as nausea, vomiting, dizziness, and headache. This bioequivalence study was performed in 24 healthy Thai males (mean [SD] age, 20.5 [1.3] years; range, 19-24 years; weight, 62.5 [7.4] kg; height, 172.8 [6.9] cm; body mass index, 20.9 [2.0] kg/m(2)). The mean (SD) C(max) and T(max) of the test formulation of lamotrigine were 1.7 (0.3) microg/mL and 1.2 (0.9) hours, respectively. The mean (SD) C(max) and T(max) of the reference formulation of lamotrigine were 1.7 (0.3) microg/mL and 1.4 (1.0) hours, respectively. The mean (SD) AUC(0-t) was 67.1 (13.2) microg/mL x h(-1) for the test product and 66.4 (14.6) microg/mL x h(-1) for the reference product. The mean (SD) AUC(0-infinity) was 74.9 (18.3) microg/mL x h(-1) for the test product and 74.3 (20.5) microg/mL x h(-1) for the reference product. The mean (SD) t((1/2)) values were 35.0 (7.6) hours for the test product and 34.7 (7.6) hours for the reference product. The mean test/reference ratios for AUC(0-t), AUC(0-infinity), and Cmax were 1.01, 1.01, and 1.05, respectively. The parametric 90% CIs for AUC(0-t), AUC(0-infinity), and Cmax were 0.98 to 1.05, 0.98 to 1.06, and 0.98 to 1.13, respectively. Following administration, dizziness or headache was reported in 2 subjects in the test group and 1 subject in the reference group. The results of this study suggest that the test product was bioequivalent to the reference product in these healthy Thai male subjects, based on the US FDA's regulatory definition.

  18. Toxicity of chloride under winter low-flow conditions in an urban watershed in central Missouri, USA

    USGS Publications Warehouse

    Allert, Ann L.; Cole-Neal, Cavelle L.; Fairchild, James F.

    2012-01-01

    Deicers such as sodium chloride and calcium chloride are used to treat snow and ice on road surfaces and have been identified as potential stressors on aquatic life. Hinkson Creek is an urban stream on the Missouri 303(d) list of impaired waters and is classified as impaired due to urban non-point source pollution. A 7-day toxicity test using Ceriodaphnia dubia was conducted to assess the toxicity of stream water during snowmelt at seven sites within the Hinkson Creek watershed. Chloride concentrations at two sites (Site 6, 1252 mg Cl/L; Site 4, 301 mg Cl/L) exceeded the U.S. Environmental Protection Agency chronic criterion (230 mg Cl/L). Survival (30 %) and total reproduction (6.9 young/adult) of C. dubia at Site 6 was significantly lower than survival (100 %) and total reproduction (30.4 young/adult) at Site 1 (reference site). Results indicate that chloride concentrations are elevated above water-quality criteria and that chloride may be a significant chemical stressor for macroinvertebrate communities during winter low-flow conditions in the Hinkson Creek watershed.

  19. Toxicity of chloride under winter low-flow conditions in an urban watershed in central Missouri, USA.

    PubMed

    Allert, Ann L; Cole-Neal, Cavelle L; Fairchild, James F

    2012-08-01

    Deicers such as sodium chloride and calcium chloride are used to treat snow and ice on road surfaces and have been identified as potential stressors on aquatic life. Hinkson Creek is an urban stream on the Missouri 303(d) list of impaired waters and is classified as impaired due to urban non-point source pollution. A 7-day toxicity test using Ceriodaphnia dubia was conducted to assess the toxicity of stream water during snowmelt at seven sites within the Hinkson Creek watershed. Chloride concentrations at two sites (Site 6, 1252 mg Cl/L; Site 4, 301 mg Cl/L) exceeded the U.S. Environmental Protection Agency chronic criterion (230 mg Cl/L). Survival (30 %) and total reproduction (6.9 young/adult) of C. dubia at Site 6 was significantly lower than survival (100 %) and total reproduction (30.4 young/adult) at Site 1 (reference site). Results indicate that chloride concentrations are elevated above water-quality criteria and that chloride may be a significant chemical stressor for macroinvertebrate communities during winter low-flow conditions in the Hinkson Creek watershed.

  20. Characterization of thyroid function and antithyroid antibody tests among Saudis

    PubMed Central

    Jammah, Anwar A.; Alshehri, Anwar S.; Alrakhis, Afaf A.; Alhedaithy, Asma S.; Almadhi, Asma M.; Alkwai, Hala M.; Alhamad, Maram M.; Alzahrani, Saad H.

    2015-01-01

    Objective: To determine the reference intervals for thyroid function tests and the prevalence of thyroid autoimmunity in the Saudi population. Methods: A cross-sectional prospective study was conducted in King Khalid University Hospital, Riyadh, Saudi Arabia from January to June 2013. History and physical examination were obtained. Thyroid-stimulating hormone (TSH), free thyroxine (FT4), and free triiodothyronine (FT3) were measured by Electro-chemiluminescence Immunoassay system-assay. Anti-thyroperoxidase, and anti-thyroglobulin antibodies were measured using enzyme-linked immunosorbent-assay. Subjects with previous or a family history of thyroid disorders, those taking medications affecting thyroid function, pregnant or lactating women, and those with goiter were excluded. Individuals with positive antibodies were excluded from the final analysis of the TSH reference range, but were used to determine the prevalence of thyroid autoimmunity. Results: Out of 337 Saudi subjects initially screened, 132 (aged 13-60 years) were candidates for reference calculation, the mean±standard deviation, and (2.5th-97.5th) percentile of TSH (mIU/L) was 1.96±0.9 (0.59-4.37), for FT4 (pmol/L) was 15.47±1.83 (12.04-19.13), and for FT3 (pmol/L) was 5.22±0.7 (4.07-6.76). The TSH was higher in the antibodies positive group (2.5±1.17 mIU/L) compared with the negative one (1.96±0.9 mIU/L) (p<0.05). Finally, 26% of subjects were tested positive for antithyroid antibodies. Conclusion: The TSH reference range was similar to laboratory references. Thyroid antibodies were prevalent in Saudis, necessitating further work in larger scale studies. PMID:25987111

  1. Characterization of thyroid function and antithyroid antibody tests among Saudis.

    PubMed

    Jammah, Anwar A; Alshehri, Anwar S; Alrakhis, Afaf A; Alhedaithy, Asma S; Almadhi, Asma M; Alkwai, Hala M; Alhamad, Maram M; Alzahrani, Saad H

    2015-06-01

    To determine the reference intervals for thyroid function tests and the prevalence of thyroid autoimmunity in the Saudi population.   A cross-sectional prospective study was conducted in King Khalid University Hospital, Riyadh, Saudi Arabia from January to June 2013. History and physical examination were obtained. Thyroid-stimulating hormone (TSH), free thyroxine (FT4), and free triiodothyronine (FT3) were measured by Electro-chemiluminescence Immunoassay system-assay. Anti-thyroperoxidase, and anti-thyroglobulin antibodies were measured using enzyme-linked immunosorbent-assay. Subjects with previous or a family history of thyroid disorders, those taking medications affecting thyroid function, pregnant or lactating women, and those with goiter were excluded. Individuals with positive antibodies were excluded from the final analysis of the TSH reference range, but were used to determine the prevalence of thyroid autoimmunity.   Out of 337 Saudi subjects initially screened, 132 (aged 13-60 years) were candidates for reference calculation, the mean±standard deviation, and (2.5th-97.5th) percentile of TSH (mIU/L) was 1.96±0.9 (0.59-4.37), for FT4 (pmol/L) was 15.47±1.83 (12.04-19.13), and for FT3 (pmol/L) was 5.22±0.7 (4.07-6.76). The TSH was higher in the antibodies positive group (2.5±1.17 mIU/L) compared with the negative one (1.96±0.9 mIU/L) (p less than 0.05). Finally, 26% of subjects were tested positive for antithyroid antibodies.   The TSH reference range was similar to laboratory references. Thyroid antibodies were prevalent in Saudis, necessitating further work in larger scale studies.

  2. Synthesis, antibacterial activity, synergistic effect, cytotoxicity, docking and molecular dynamics of benzimidazole analogues.

    PubMed

    Srivastava, Ritika; Gupta, Sunil K; Naaz, Farha; Singh, Anuradha; Singh, Vishal K; Verma, Rajesh; Singh, Nidhi; Singh, Ramendra K

    2018-05-24

    A series of 2-Cl-benzimidazole derivatives was synthesized and assessed for antibacterial activity. Antibacterial results indicated that compounds 2d, 2e, 3a, 3b, 3c, 4d and 4e showed promising activity against B. cerus, S. aureus and P. aeruginosa (MIC: 6.2 μg/mL) and excellent efficacy against E. coli (MIC: 3.1 μg/mL). Furthermore, compounds 3d and 3e displayed better activity (MIC: 3.1 μg/mL) than the reference drugs chloramphenicol and cycloheximide against gram positive and gram negative bacterial strains. The compounds 3d-e also showed better activity than the reference drug paromomycin against B. cerus and P. aeruginosa and showed similar inhibition pattern against S. aureus and E. coli. (MIC: 3.1 μg/mL). Studies on fractional inhibitory concentration (FIC) determination of compounds 1a-e, 2a-c, 4a-c and the reference antibiotic via combination approach revealed a synergistic effect as the MIC values were lowered up to 1 / 8 th to 1 / 33 rd of the original MIC. In-vitro cytotoxicity study indicated that 2-Cl-benzimidazole derivatives showed less toxicity than the reference used against PBM, CEM and Vero cell lines. Docking studies and MD simulations of compounds on bacterial protein (eubacterial ribosomal decoding A site, PDB: 1j7t) have been conducted to find the possible mode of action of the molecules. In silico ADMET evaluations of compounds 3d and 3e showed promising results comparable to the reference drugs used in this study. Copyright © 2018 Elsevier Ltd. All rights reserved.

  3. Establishment of reference intervals for serum thyroid-stimulating hormone, free and total thyroxine, and free and total triiodothyronine for the Beckman Coulter DxI-800 analyzers by indirect method using data obtained from Chinese population in Zhejiang Province, China.

    PubMed

    Wang, Yan; Zhang, Yu-Xia; Zhou, Yong-Lie; Xia, Jun

    2017-07-01

    In order to establish suitable reference intervals of thyroid-stimulating hormone (TSH), free (unbound) T4 (FT4), free triiodothyronine (FT3), total thyroxine (T4), and total triiodothyronine (T3) for the patients collected in Zhejiang, China, an indirect method was developed using the data from the people presented for routine health check-up. Fifteen thousand nine hundred and fifty-six person's results were reviewed. Box-Cox or Case Rank was used to transform the data to normal distribution. Tukey and Box-Plot methods were used to exclude the outliers. Nonparametric method was used to establish the reference intervals following the EP28-A3c guideline. Pearson correlation was used to evaluate the correlation between hormone levels and age, while Mann-Whitney U test was employed for quantification of concentration differences on the people who are younger and older than 50 years old. Reference intervals were 0.66-4.95 mIU/L (TSH), 8.97-14.71 pmol/L (FT4), 3.75-5.81 pmol/L (FT3), 73.45-138.93 nmol/L (total T4), and 1.24-2.18 nmol/L (total T3) in male; conversely, reference intervals for female were 0.72-5.84 mIU/L (TSH), 8.62-14.35 pmol/L (FT4), 3.59-5.56 pmol/L (FT3), 73.45-138.93 nmol/L (total T4), and 1.20-2.10 nmol/L (total T3). FT4, FT3, and total T3 levels in male and FT4 level in female had an inverse correlation with age. Total T4 and TSH levels in female were directly correlated. Significant differences in these hormones were also found between younger and older than 50 years old except FT3 in female. Indirect method can be applied for establishment of reference intervals for TSH, FT4, FT3, total T4, and total T3. The reference intervals are narrower than those previously established. Age factor should also be considered. © 2016 Wiley Periodicals, Inc.

  4. Comparative fasting bioavailability of two clopidogrel formulations in healthy Mediterranean volunteers: an in vitro–in vivo correlation

    PubMed Central

    Zaid, Abdel Naser; Al Ramahi, Rowa’; Bustami, Rana; Mousa, Ayman; Khasawneh, Sewar

    2015-01-01

    Objective The aim of this study was to evaluate the bioequivalence of two drug products, generic clopidogrel bisulfate 75 mg film-coated tablets versus the reference Plavix® clopidogrel bisulfate 75 mg film-coated tablets. Methods Bioequivalence of tablets was tested by comparisons against the reference brand product in accordance with the requirements of the Declaration of Helsinki, the current Good Clinical Practice Guidelines, and the International Conference on Harmonization. Results The relationship between concentration and peak area ratio was found to be linear within the range 24.500–1,836.600 pg/mL for clopidogrel. The correlation coefficient (r) was always greater than 0.99 during the course of the validation. Statistical comparison of the main pharmacokinetic parameters showed no significant difference between test and reference. The point estimates (ratios of geometric mean) were 104.122%, 104.184%, and 109.091% for areas under the plasma concentration–time curve (AUC) AUC0-last, AUC0-∞, and peak plasma concentration Cmax, respectively. These pharmacokinetic parameter values of clopidogrel and its main metabolite lie within the bioequivalence limit (80%–125%) specified by the US Food and Drug Administration and the European Medicines Agency. Conclusion The tested drug product was bioequivalent to the reference drug under fasting conditions and had the same safety profile, which is important to achieve equivalent therapeutic effect with the reference. PMID:25987833

  5. Comparative fasting bioavailability of two clopidogrel formulations in healthy Mediterranean volunteers: an in vitro-in vivo correlation.

    PubMed

    Zaid, Abdel Naser; Al Ramahi, Rowa'; Bustami, Rana; Mousa, Ayman; Khasawneh, Sewar

    2015-01-01

    The aim of this study was to evaluate the bioequivalence of two drug products, generic clopidogrel bisulfate 75 mg film-coated tablets versus the reference Plavix(®) clopidogrel bisulfate 75 mg film-coated tablets. Bioequivalence of tablets was tested by comparisons against the reference brand product in accordance with the requirements of the Declaration of Helsinki, the current Good Clinical Practice Guidelines, and the International Conference on Harmonization. The relationship between concentration and peak area ratio was found to be linear within the range 24.500-1,836.600 pg/mL for clopidogrel. The correlation coefficient (r) was always greater than 0.99 during the course of the validation. Statistical comparison of the main pharmacokinetic parameters showed no significant difference between test and reference. The point estimates (ratios of geometric mean) were 104.122%, 104.184%, and 109.091% for areas under the plasma concentration-time curve (AUC) AUC0-last, AUC0-∞, and peak plasma concentration C max, respectively. These pharmacokinetic parameter values of clopidogrel and its main metabolite lie within the bioequivalence limit (80%-125%) specified by the US Food and Drug Administration and the European Medicines Agency. The tested drug product was bioequivalent to the reference drug under fasting conditions and had the same safety profile, which is important to achieve equivalent therapeutic effect with the reference.

  6. Guanidinoacetate and creatine plus creatinine assessment in physiologic fluids: an effective diagnostic tool for the biochemical diagnosis of arginine:glycine amidinotransferase and guanidinoacetate methyltransferase deficiencies.

    PubMed

    Carducci, Claudia; Birarelli, Maurizio; Leuzzi, Vincenzo; Carducci, Carla; Battini, Roberta; Cioni, Giovanni; Antonozzi, Italo

    2002-10-01

    Disorders of creatine metabolism arise from genetic alterations of arginine:glycine amidinotransferase (AGAT), guanidinoacetate methyltransferase (GAMT), and the creatine transporter. We developed a strategy for the detection of AGAT and GAMT defects by measurement of guanidinoacetate (GAA) and creatine plus creatinine (Cr+Crn) in biological fluids. Three patients with AGAT deficiency from the same pedigree and their eight relatives, as well as a patient affected by a GAMT defect and his parents were analyzed by a new HPLC procedure in comparison with 90 controls. The method, which uses precolumn derivatization with benzoin, separation with a reversed-phase column, and fluorescence detection, has shown good precision and sensitivity and requires minimal sample handling. In the three AGAT patients, plasma GAA was 0.01-0.04 micro mol/L [mean (SD) for neurologically normal controls was 1.16 (0.59) micromol/L], Cr+Crn was 15-29 micro mol/L [reference limit in our laboratory, 79 (38) micromol/L]. Urinary GAA was 2.4-5.8 micro mol/L [reference, 311 (191) micromol/L], and Cr+Crn was 2.1-3.3 mmol/L [reference, 9.9 (4.1) mmol/L]. We found a smaller decrease in GAA and Cr+Crn in some carriers of an AGAT defect. In the patient with GAMT deficiency, plasma and urine GAA was increased (18.6 and 1783 micromol/L, respectively), and Cr+Crn was decreased in plasma (10.7 micromol/L) and urine (2.1 mmol/L). GAA was increased in the parents' plasmas and in the mother's urine. The assessment of GAA is a new tool for the detection of both GAMT and AGAT deficiencies.

  7. Comparison of the Vitek 2 yeast susceptibility system with CLSI microdilution for antifungal susceptibility testing of fluconazole and voriconazole against Candida spp., using new clinical breakpoints and epidemiological cutoff values.

    PubMed

    Pfaller, Michael A; Diekema, Daniel J; Procop, Gary W; Rinaldi, Michael G

    2013-09-01

    A commercially available, fully automated yeast susceptibility test system (Vitek 2; bioMérieux, Marcy d'Etoile, France) was compared in 3 different laboratories with the Clinical and Laboratory Standards Institute (CLSI) reference microdilution (BMD) method by testing 2 quality control strains, 10 reproducibility strains, and 425 isolates of Candida spp. against fluconazole and voriconazole. Reference CLSI BMD MIC endpoints and Vitek 2 MIC endpoints were read after 24 hours and 9.1-27.1 hours incubation, respectively. Excellent essential agreement (within 2 dilutions) between the reference and Vitek 2 MICs was observed for fluconazole (97.9%) and voriconazole (96.7%). Categorical agreement (CA) between the 2 methods was assessed using the new species-specific clinical breakpoints (CBPs): susceptible (S) ≤2 μg/mL, susceptible dose-dependent (SDD) 4 μg/mL, and resistant (R) ≥8 μg/mL for fluconazole and Candida albicans, Candida tropicalis, and Candida parapsilosis and ≤32 μg/mL (SDD), ≥64 μg/mL (R) for Candida glabrata; S ≤0.12 μg/mL, SDD 0.25-0.5 μg/mL, R ≥1 μg/mL for voriconazole and C. albicans, C. tropicalis, and C. parapsilosis, and ≤0.5 μg/mL (S), 1 μg/mL (SDD), ≥2 μg/mL (R) for Candida krusei. The epidemiological cutoff value (ECV) of 0.5 μg/mL for voriconazole and C. glabrata was used to differentiate wild-type (WT; MIC ≤ ECV) from non-WT (MIC > ECV) strains of this species. Due to the lack of CBPs for the less common species, the ECVs for fluconazole and voriconazole, respectively, were used for Candida lusitaniae (2 μg/mL and 0.03 μg/mL), Candida dubliniensis (0.5 μg/mL and 0.03 μg/mL), Candida guilliermondii (8 μg/mL and 0.25 μg/mL), and Candida pelliculosa (4 μg/mL and 0.25 μg/mL) to categorize isolates of these species as WT and non-WT. CA between the 2 methods was 96.8% for fluconazole and 96.5% for voriconazole with less than 1% very major errors and 1.3-3.0% major errors. The Vitek 2 yeast susceptibility system remains comparable to the CLSI BMD reference method for testing the susceptibility of Candida spp. when using the new (lower) CBPs and ECVs. © 2013.

  8. Biological instability in a chlorinated drinking water distribution network.

    PubMed

    Nescerecka, Alina; Rubulis, Janis; Vital, Marius; Juhna, Talis; Hammes, Frederik

    2014-01-01

    The purpose of a drinking water distribution system is to deliver drinking water to the consumer, preferably with the same quality as when it left the treatment plant. In this context, the maintenance of good microbiological quality is often referred to as biological stability, and the addition of sufficient chlorine residuals is regarded as one way to achieve this. The full-scale drinking water distribution system of Riga (Latvia) was investigated with respect to biological stability in chlorinated drinking water. Flow cytometric (FCM) intact cell concentrations, intracellular adenosine tri-phosphate (ATP), heterotrophic plate counts and residual chlorine measurements were performed to evaluate the drinking water quality and stability at 49 sampling points throughout the distribution network. Cell viability methods were compared and the importance of extracellular ATP measurements was examined as well. FCM intact cell concentrations varied from 5×10(3) cells mL(-1) to 4.66×10(5) cells mL(-1) in the network. While this parameter did not exceed 2.1×10(4) cells mL(-1) in the effluent from any water treatment plant, 50% of all the network samples contained more than 1.06×10(5) cells mL(-1). This indisputably demonstrates biological instability in this particular drinking water distribution system, which was ascribed to a loss of disinfectant residuals and concomitant bacterial growth. The study highlights the potential of using cultivation-independent methods for the assessment of chlorinated water samples. In addition, it underlines the complexity of full-scale drinking water distribution systems, and the resulting challenges to establish the causes of biological instability.

  9. Xerostomia after radiotherapy and its effect on quality of life in head and neck cancer patients.

    PubMed

    Kakoei, Shahla; Haghdoost, Ali-Akbar; Rad, Maryam; Mohammadalizadeh, Sakineh; Pourdamghan, Nasim; Nakhaei, Mahdieh; Bahador, Maryam

    2012-04-01

    Xerostomia is one of the one complications following radiotherapy that can affect quality of life (QoL). This study aims to assess the severity of xerostomia in patients with head and neck cancers after radiotherapy and its effect on QoL. In this longitudinal prospective study, the severity of xerostomia and related QoL were was assessed in 63 head and neck cancer patients who referred to the Radiotherapy Ward. Patients completed a xerostomia questionnaire (XQ) at the beginning, and 2, 4, and 6 weeks after treatment over a period of 6 months. Additionally, unstimulated saliva was collected using the spitting method at all 4 visits. QoL significantly worsened with increased time (P = 0.0001); meanwhile, the severity of xerostomia increased significantly (P = 0.0001). However, there was no significant change in the amount of saliva at these 4 time points (P = 0.23). Regression analysis showed that with each milliliter decrease in saliva secretion, the QoL score decreased 2.25%. With one score increase in xerostomia, from the QoL mean score there was a 1.65% decrease. The decrease in saliva and xerostomia that resulted from radiotherapy plays an important role in worsening QoL among patients who undergo radiotherapy for head and neck cancers. Although the amount of saliva has a significant association with QoL, the xerostomia score which shows subjects' general feeling also independently impacts QoL. In future studies, we recommend patient assessments for periods longer than 6 months.

  10. Gender's equality in evaluation of urine particles: Results of a multicenter study of the Italian Urinalysis Group.

    PubMed

    Manoni, Fabio; Gessoni, Gianluca; Alessio, Maria Grazia; Caleffi, Alberta; Saccani, Graziella; Epifani, Maria Grazia; Tinello, Agostino; Zorzan, Tatiana; Valverde, Sara; Caputo, Marco; Lippi, Giuseppe

    2014-01-01

    We performed a multicenter study to calculate the upper reference limits (URL) for urine particle quantification in mid-stream samples by using automated urine analyzers. Two laboratories tested 283 subjects using a Sysmex UF-100, two other laboratories tested 313 subjects using Sysmex UF-1000i, whereas two other laboratories tested 267 subjects using Iris IQ®200. The URLs of UF-100 in females and males were 7.8/μL and 6.7/μL for epithelial cells (EC), 11.1/μL and 9.9/μL for red blood cells (RBC), 10.2/μL and 9.7/μL for white blood cells (WBC), and 0.85/μL and 0.87/μL for cylinders (CAST). The URLs of UF-1000i in females and males were 7.6/μL and 7.1/μL for EC, 12.2/μL and 11.1/μL for RBC, 11.9/μL and 11.7/μL for WBC, and 0.88/μL and 0.86/μL for CAST. The URLs of Iris IQ®200 in females and males were 7.8/μL and 6.6/μL for EC, 12.4/μL and 10.1/μL for RBC, 10.9/μL and 9.9/μL for WBC, and 1.1/μL and 1.0/μL for CAST. The URLs obtained in this study were comparable to the lowest values previously reported in the literature. Moreover, no gender-related difference was observed, and analyzer-specific upper reference limits were very similar. © 2013.

  11. Diagnostic accuracy of point-of-care natriuretic peptide testing for chronic heart failure in ambulatory care: systematic review and meta-analysis.

    PubMed

    Taylor, Kathryn S; Verbakel, Jan Y; Feakins, Benjamin G; Price, Christopher P; Perera, Rafael; Bankhead, Clare; Plüddemann, Annette

    2018-05-21

    To assess the diagnostic accuracy of point-of-care natriuretic peptide tests in patients with chronic heart failure, with a focus on the ambulatory care setting. Systematic review and meta-analysis. Ovid Medline, Cochrane Central Register of Controlled Trials, Cochrane Database of Systematic Reviews, Database of Abstracts of Reviews of Effects, Embase, Health Technology Assessment Database, Science Citation Index, and Conference Proceedings Citation Index until 31 March 2017. Eligible studies evaluated point-of-care natriuretic peptide testing (B-type natriuretic peptide (BNP) or N terminal fragment pro B-type natriuretic peptide (NTproBNP)) against any relevant reference standard, including echocardiography, clinical examination, or combinations of these, in humans. Studies were excluded if reported data were insufficient to construct 2×2 tables. No language restrictions were applied. 42 publications of 39 individual studies met the inclusion criteria and 40 publications of 37 studies were included in the analysis. Of the 37 studies, 30 evaluated BNP point-of-care testing and seven evaluated NTproBNP testing. 15 studies were done in ambulatory care settings in populations with a low prevalence of chronic heart failure. Five studies were done in primary care. At thresholds >100 pg/mL, the sensitivity of BNP, measured with the point-of-care index device Triage, was generally high and was 0.95 (95% confidence interval 0.90 to 0.98) at 100 pg/mL. At thresholds <100 pg/mL, sensitivity ranged from 0.46 to 0.97 and specificity from 0.31 to 0.98. Primary care studies that used NTproBNP testing reported a sensitivity of 0.99 (0.57 to 1.00) and specificity of 0.60 (0.44 to 0.74) at 135 pg/mL. No statistically significant difference in diagnostic accuracy was found between point-of-care BNP and NTproBNP tests. Given the lack of studies in primary care, the paucity of NTproBNP data, and potential methodological limitations in these studies, large scale trials in primary care are needed to assess the role of point-of-care natriuretic peptide testing and clarify appropriate thresholds to improve care of patients with suspected or chronic heart failure. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  12. Ecosystem approach to fisheries: Exploring environmental and trophic effects on Maximum Sustainable Yield (MSY) reference point estimates

    PubMed Central

    Kumar, Rajeev; Pitcher, Tony J.; Varkey, Divya A.

    2017-01-01

    We present a comprehensive analysis of estimation of fisheries Maximum Sustainable Yield (MSY) reference points using an ecosystem model built for Mille Lacs Lake, the second largest lake within Minnesota, USA. Data from single-species modelling output, extensive annual sampling for species abundances, annual catch-survey, stomach-content analysis for predatory-prey interactions, and expert opinions were brought together within the framework of an Ecopath with Ecosim (EwE) ecosystem model. An increase in the lake water temperature was observed in the last few decades; therefore, we also incorporated a temperature forcing function in the EwE model to capture the influences of changing temperature on the species composition and food web. The EwE model was fitted to abundance and catch time-series for the period 1985 to 2006. Using the ecosystem model, we estimated reference points for most of the fished species in the lake at single-species as well as ecosystem levels with and without considering the influence of temperature change; therefore, our analysis investigated the trophic and temperature effects on the reference points. The paper concludes that reference points such as MSY are not stationary, but change when (1) environmental conditions alter species productivity and (2) fishing on predators alters the compensatory response of their prey. Thus, it is necessary for the management to re-estimate or re-evaluate the reference points when changes in environmental conditions and/or major shifts in species abundance or community structure are observed. PMID:28957387

  13. Enumerative Geometry of Hyperplane Arrangements

    DTIC Science & Technology

    2012-05-11

    they show that the Zariski closure of M(L) as viewed as a subvariety of (Cn+1)` is not the variety given only by the solutions to the determinantal ...equations supplied by L. These determinantal equations are presented nicely in Terao [28]. We study in detail the case when L is the lattice of the braid...4.1.1. Let A be a generic arrangement of 4 lines through 8 points in general position in P2. There are no triple points inA, so there are no determinantal

  14. Minimal clinically important improvement (MCII) and patient-acceptable symptom state (PASS) in total hip arthroplasty (THA) patients 1 year postoperatively

    PubMed Central

    Paulsen, Aksel

    2014-01-01

    Background and purpose The increased use of patient-reported outcomes (PROs) in orthopedics requires data on estimated minimal clinically important improvements (MCIIs) and patient-acceptable symptom states (PASSs). We wanted to find cut-points corresponding to minimal clinically important PRO change score and the acceptable postoperative PRO score, by estimating MCII and PASS 1 year after total hip arthroplasty (THA) for the Hip Dysfunction and Osteoarthritis Outcome Score (HOOS) and the EQ-5D. Patients and methods THA patients from 16 different departments received 2 PROs and additional questions preoperatively and 1 year postoperatively. The PROs included were the HOOS subscales pain (HOOS Pain), physical function short form (HOOS-PS), and hip-related quality of life (HOOS QoL), and the EQ-5D. MCII and PASS were estimated using multiple anchor-based approaches. Results Of 1,837 patients available, 1,335 answered the preoperative PROs, and 1,288 of them answered the 1-year follow-up. The MCIIs and PASSs were estimated to be: 24 and 91 (HOOS Pain), 23 and 88 (HOOS-PS), 17 and 83 (HOOS QoL), 0.31 and 0.92 (EQ-5D Index), and 23 and 85 (EQ-VAS), respectively. MCIIs corresponded to a 38–55% improvement from mean baseline PRO score and PASSs corresponded to absolute follow-up scores of 57–91% of the maximum score in THA patients 1 year after surgery. Interpretation This study improves the interpretability of PRO scores. The different estimation approaches presented may serve as a guide for future MCII and PASS estimations in other contexts. The cutoff points may serve as reference values in registry settings. PMID:24286564

  15. Intensity related changes of running economy in recreational level distance runners.

    PubMed

    Engeroff, Tobias; Bernardi, Andreas; Niederer, Daniel; Wilke, Jan; Vogt, Lutz; Banzer, Winfried

    2017-09-01

    Running economy (RE) is often described as a key demand of running performance. The variety of currently used assessment methods with different running intensities and outcomes restricts interindividual comparability of RE in recreational level runners. The purpose of this study was to compare the influence of RE, assessed as oxygen cost (OC) and caloric unit cost (CUC), on running speed at individual physiological thresholds. Eighteen recreational runners performed: 1) a graded exercise test to estimate first ventilatory threshold (VT1), respiratory compensation point (RCP) and maximal oxygen uptake (VO2max); 2) discontinuous RE assessment to determine relative OC in milliliters per kilogram per kilometer (mL/kg/km) and CUC in kilocalories per kilogram per kilometer (kcal/kg/km) at three different running intensities: VT1, RCP and at a third standardized reference point (TP) in between. OC (mL/kg/km; at VT1: 235.4±26.2; at TP: 227.8±23.4; at RCP: 224.9±21.9) and CUC (kcal/kg/km at VT1: 1.18±0.13; at TP: 1.14±0.12; at RCP: 1.13±0.11) decreased with increasing intensities (P≤0.01). Controlling for the influence of sex OC and CUC linearly correlated with running speed at RCP and VO2max (P≤0.01). RE, even assessed at low intensity, is strongly related to running performance in recreational athletes. Both calculation methods used (OC and CUC) are sensitive for monitoring intensity related changes of substrate utilization. RE values decreased with higher running intensity indicating an increase of anaerobic and subsequent decrease of aerobic substrate utilization.

  16. THE PECULIAR LIGHT CURVE OF THE SYMBIOTIC STAR AX PER OF THE LAST 125 YEARS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Leibowitz, Elia M.; Formiggini, Liliana, E-mail: elia@wise.tau.ac.il

    We analyze the optical light curve (LC) of the last 125 years of the symbiotic star AX Per through some remarkable correlations that we discovered in its power spectrum (PS). The data were assembled from the literature and from the American Association of Variable Stars Observers database. A series of six major outbursts dominate the LC. They are presented in the PS as 13 harmonics of the fundamental frequency f {sub a} = 1/P {sub a} = 1/23,172 day{sup –1}. We refer to them as the ''red'' frequencies. Oscillations with the binary periodicity of the system P {sub b} =more » 1/f {sub b} = 681.48 days are also seen in the LC, with particularly large amplitudes during outbursts. The f {sub b} peak in the PS is accompanied by 13 other peaks on each side, which we refer to as the ''blue'' frequencies. A distinct structure in the frequency distribution of the blue peaks, as well as in their peak power, is best interpreted as reflecting beating of the 13 ''red'' frequencies with the binary one. We suggest, following others, that the major outbursts of the system result from events of intense mass loss from the giant star. Mass accretion onto the hot component, partially through the L1 point of the system, took place in the last 125 years at a rate that oscillated with the 13 first harmonics of the f {sub a} frequency. The binary orbit is slightly eccentric and periastron passages induced modulation of the L1 accretion at the binary frequency. Hence the f {sub b} oscillations in the brightness of the star of an amplitude that is modulated by the ''red'' frequencies of the system.« less

  17. Resource Letter L-1: Lasers.

    ERIC Educational Resources Information Center

    O'Shea, Donald C.; Peckham, Donald C.

    1981-01-01

    Following a brief introduction, an annotated listing of literature and teaching aids on lasers is presented. Categories include: Background Materials; Historical References; General References and Textbooks; Specialized References; Reviews; Articles; Films; Laser Courses; Equipment, Demonstrations, and Experiments; Laser Safety; and Lasers and…

  18. [Reference values for lead in blood in urban population in southern Brazil].

    PubMed

    Paoliello, M M; Gutierrez, P R; Turini, C A; Matsuo, T; Mezzaroba, L; Barbosa, D S; Carvalho, S R; Alvarenga, A L; Rezende, M I; Figueiroa, G A; Leite, V G; Gutierrez, A C; Lobo, B C; Cascales, R A

    2001-05-01

    To describe the reference values for lead in blood in an urban population in the city of Londrina, in the state of Paraná, Brazil. The reference population was composed of 520 adult volunteers who were assessed from November 1994 to December 1996. Exclusion criteria were: occupational exposure to lead, exposure through personal habits or practices, smoking more than 10 cigarettes per day, and living near industrial plants or other places that use lead in their production processes. Also excluded were individuals with abnormal clinical or laboratory results or with chronic diseases or cardiovascular disorders. Lead blood levels were determined using air-acetylene flame atomic absorption spectrophotometry. The detectable limit was 1.23 micrograms/dL. After the analyses of lead in blood, the following values were determined: minimum value, first quartile, median, third quartile, and maximum value; geometric mean; 95% confidence interval; experimental interval; and reference value. The reference values for lead in blood ranged from 1.20 micrograms/dL to 13.72 micrograms/dL. The geometric mean was 5.5 micrograms/dL. In general, the values found in this study are lower than those that have been reported for other countries. Additional data should be gathered from Brazilian populations living in more-industrialized areas.

  19. Technical note: Evaluation of digital refractometers to estimate serum immunoglobulin G concentration and passive transfer in Jersey calves.

    PubMed

    McCracken, M M; Morrill, K M; Fordyce, A L; Tyler, H D

    2017-10-01

    Previous data have demonstrated that refractometers can be used to estimate serum IgG, and that a cut-point of 7.8% Brix should be used to identify failure of passive transfer (FPT) in 1-d-old Holstein calves. The objective of the present study was to validate the use of refractometry to estimate serum IgG concentrations and evaluate FPT in Jersey calves. Blood samples (n = 97) were obtained from 1- to 3-d-old Jersey calves and centrifuged at 3,300 × g for 20 min at 25°C. Serum was analyzed for % Brix, total protein (TP), and refractive index (nD) using a Sper Scientific Digital Refractometer (model #300036, Sper Scientific, Scottsdale, AZ) within 12 h of sampling. Samples were then frozen and later analyzed in the laboratory for IgG by radial immunodiffusion. The mean serum IgG concentration for all calves was 23.7 mg/mL (SD = 12.5), with a range of 2.3 to 65.5 mg/mL. Mean serum % Brix was 8.9 (SD = 1.1; range 6.5 to 12.0). Serum % Brix was moderately correlated with IgG concentration (r = 0.77). Total protein and IgG were moderately correlated (r = 0.790). Regression was used to determine cut-points for approximately 10, 12, and 14 mg of IgG/mL and to determine the sensitivity and specificity of refractometry to identify FPT (serum IgG <10 mg/mL at 24 h of life). Brix cut-points analyzed were 7.1, 7.3, and 7.6%; TP cut-points were 4.6, 5.0, and 5.5 g/dL; and nD cut-points were 1.34332, 1.34271, and 1.3448, respectively, for 10, 12, and 14 mg of IgG/mL. The 7.3% Brix and 4.6 g/dL TP cut-points resulted in the greatest percentage of samples being correctly classified. These data suggest that digital refractometry is an acceptable and rapid method to estimate immunoglobulin G in Jersey calf serum. Copyright © 2017 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  20. [Reference values of neonatal erythrocyte and leukocyte count in Bamako, Mali].

    PubMed

    Diallo, Dapa Aly; Diawara, Faoumata; Guindo, Aldiouma; Touré, Moustaph; Traoré, Mamadou; Fofana, Aïssata Traoré; Dembélé, Albdoul K; Guindo, Agnès; Diallo, Yacouba Lazare; Diallo, Oumahane; Baraika, Ag Mohamed; Dolo, Amadou Ingré

    2013-01-01

    Reference values for blood cell count are not established at birth in Mali. This study aimed to determine reference values for erythrocyte and leukocyte at birth in Bamako. Blood was collected from the umbilical cord immediately following its clamping and studied for complete blood cell count in 481 newborns with a birth weight > 2500g, Apgar score ≤ 7 at 5 or 10 minutes, without abnormal hemoglobin mutations and whose mothers were willing in Bamako, Mali. Other than the median and mean values, 2.5 and 97.5 percentiles were calculated. The findings suggest that the normal reference values following a timely clamping of the umbilical cord were (mean ± 1SD and range): RBC = 4,00 ± 0,46.1012/L (3,13 - 4,89), Hb = 14,12 ± 1,49 g/dL (11,20 - 17,00), Hct = 40,27 ± 4,71% (31,62 - 50,18), MCV = 101 ± 5 fl (91 - 112), MCHC = 35,37 ± 2,16 pg/cellule (30,70 - 39,59), MCH = 35,06 ± 0,93 g/dL (33,40 - 36,90), RDW = 17,79 ± 7,33% (15,50 - 20,39), Reticulocytes (109/L) = 133,081 ± 29,95 (66,62 - 200,86), GB (109/L) = 13,24 ± 7,23 (7,20 - 23,70), PMN (109/L) = 7,16 ± 4,70 (3,07 - 14,22), PME (109/L) = 0,28 ± 0,26 (0 - 0,98), PMB(109/L) = 0,05 ± 0,09 (0 - 0,31), Lymphocytes (109/L) = 4,49 ± 2,45 (1,96 - 9,42), Monocytes (10 9 /L) = 1,06 ± 0,73 (0,21 - 2,54), myelocytes = 1.43 ± 1.51%, erythroblasts = 4.52 ± 7.83%. It should be noted that male babies had a lower neutrophil count than female newborns. By taking into account these results when interpreting the blood cell count in Malian newborn infants, costly misdiagnoses should be considerably decreased in a population struggling with low incomes. Le comitée de rédaction se réserve le droit de revoyer aux auteurs avant toute soumission à l'avis des lecteurs les manuscrits qui ne seraient pas conformes à ces modalités de présentation. En outre il leur conseille de sonserver un examplaire du manuscrit, des figures et des tableaux.

  1. Development of a Multiple-Locus Variable number of tandem repeat Analysis (MLVA) for Leptospira interrogans and its application to Leptospira interrogans serovar Australis isolates from Far North Queensland, Australia

    PubMed Central

    Slack, Andrew T; Dohnt, Michael F; Symonds, Meegan L; Smythe, Lee D

    2005-01-01

    Background Leptospirosis is a zoonotic disease caused by the genus, Leptospira. Leptospira interrogans is the most common genomospecies implicated in the disease. Epidemiological investigations are needed to distinguish outbreak situations or to trace reservoirs of the organisms. Current methodologies used for typing Leptospira have significant drawbacks. The development of an easy to perform yet high resolution method is needed for this organism. Methods In this study we have searched the available genomic sequence of L. interrogans serovar Copenhageni strain Fiocruz L1-130 for the presence of tandem repeats [1]. These repeats were evaluated against reference strains for diversity. Six loci were selected to create a Multiple Locus Variable Number of Tandem Repeats (VNTR) Analysis (MLVA) to explore the genetic diversity within L. interrogans serovar Australis clinical isolates from Far North Queensland. Results The 39 reference strains used for the development of the method displayed 39 distinct patterns. Diversity Indexes for the loci varied between 0.80 and 0.93 and the number of repeat units at each locus varied between less than one to 52 repeats. When the MLVA was applied to serovar Australis isolates three large clusters were distinguishable, each comprising various hosts including Rattus species, human and canines. Conclusion The MLVA described in this report, was easy to perform, analyse and was reproducible. The loci selected had high diversity allowing discrimination between serovars and also between strains within a serovar. This method provides a starting point on which improvements to the method and comparisons to other techniques can be made. PMID:15987533

  2. "Keep your eyes on the prize": reference points and racial differences in assessing progress toward equality.

    PubMed

    Eibach, Richard P; Ehrlinger, Joyce

    2006-01-01

    White Americans tend to perceive greater progress toward racial equality than do ethnic minorities. Correlational evidence (Study 1) and two experimental manipulations of framing (Studies 2 and 3) supported the hypothesis that this perception gap is associated with different reference points the two groups spontaneously use to assess progress, with Whites anchoring on comparisons with the past and ethnic minorities anchoring on ideal standards. Consistent with the hypothesis that the groups anchor on different reference points, the gap in perceptions of progress was affected by the time participants spent deliberating about the topic (Study 4). Implications for survey methods and political conflict are discussed.

  3. Earth to Moon Transfer: Direct vs Via Libration Points (L1, L2)

    NASA Technical Reports Server (NTRS)

    Condon, Gerald L.; Wilson, Samuel W.

    2004-01-01

    For some three decades, the Apollo-style mission has served as a proven baseline technique for transporting flight crews to the Moon and back with expendable hardware. This approach provides an optimal design for expeditionary missions, emphasizing operational flexibility in terms of safely returning the crew in the event of a hardware failure. However, its application is limited essentially to low-latitude lunar sites, and it leaves much to be desired as a model for exploratory and evolutionary programs that employ reusable space-based hardware. This study compares the performance requirements for a lunar orbit rendezvous mission type with one using the cislunar libration point (L1) as a stopover and staging point for access to arbitrary sites on the lunar surface. For selected constraints and mission objectives, it contrasts the relative uniformity of performance cost when the L1 staging point is used with the wide variation of cost for the Apollo-style lunar orbit rendezvous.

  4. Orbit Determination (OD) Error Analysis Results for the Triana Sun-Earth L1 Libration Point Mission and for the Fourier Kelvin Stellar Interferometer (FKSI) Sun-Earth L2 Libration Point Mission Concept

    NASA Technical Reports Server (NTRS)

    Marr, Greg C.

    2003-01-01

    The Triana spacecraft was designed to be launched by the Space Shuttle. The nominal Triana mission orbit will be a Sun-Earth L1 libration point orbit. Using the NASA Goddard Space Flight Center's Orbit Determination Error Analysis System (ODEAS), orbit determination (OD) error analysis results are presented for all phases of the Triana mission from the first correction maneuver through approximately launch plus 6 months. Results are also presented for the science data collection phase of the Fourier Kelvin Stellar Interferometer Sun-Earth L2 libration point mission concept with momentum unloading thrust perturbations during the tracking arc. The Triana analysis includes extensive analysis of an initial short arc orbit determination solution and results using both Deep Space Network (DSN) and commercial Universal Space Network (USN) statistics. These results could be utilized in support of future Sun-Earth libration point missions.

  5. Towards an automatic lab-on-valve-ion mobility spectrometric system for detection of cocaine abuse.

    PubMed

    Cocovi-Solberg, David J; Esteve-Turrillas, Francesc A; Armenta, Sergio; de la Guardia, Miguel; Miró, Manuel

    2017-08-25

    A lab-on-valve miniaturized system integrating on-line disposable micro-solid phase extraction has been interfaced with ion mobility spectrometry for the accurate and sensitive determination of cocaine and ecgonine methyl ester in oral fluids. The method is based on the automatic loading of 500μL of oral fluid along with the retention of target analytes and matrix clean-up by mixed-mode cationic/reversed-phase solid phase beads, followed by elution with 100μL of 2-propanol containing (3% v/v) ammonia, which are online injected into the IMS. The sorptive particles are automatically discarded after every individual assay inasmuch as the sorptive capacity of the sorbent material is proven to be dramatically deteriorated with reuse. The method provided a limit of detection of 0.3 and 0.14μgL -1 for cocaine and ecgonine methyl ester, respectively, with relative standard deviation values from 8 till 14% with a total analysis time per sample of 7.5min. Method trueness was evaluated by analyzing oral fluid samples spiked with cocaine at different concentration levels (1, 5 and 25μgL -1 ) affording relative recoveries within the range of 85±24%. Fifteen saliva samples were collected from volunteers and analysed following the proposed automatic procedure, showing a 40% cocaine occurrence with concentrations ranging from 1.3 to 97μgL -1 . Field saliva samples were also analysed by reference methods based on lateral flow immunoassay and gas chromatography-mass spectrometry. The application of this procedure to the control of oral fluids of cocaine consumers represents a step forward towards the development of a point-of-care cocaine abuse sensing system. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. Long Term Measurement of the Vapor Pressure of Gold in the Au-C System

    NASA Technical Reports Server (NTRS)

    Copland, Evan H.

    2009-01-01

    Incorporating the {Au(s,l) + graphite} reference in component activity measurements made with the multiple effusion-cell vapor source mass spectrometry (multicell KEMS) technique provides a fixed temperature defining ITS-90 (T(sub mp)(Au) = 1337.33K) and a systematic method to check accuracy. Over a 2 year period delta H sub(298)Au was determined by the 2nd and 3rd law methods in 25 separate experiments and were in the ranges 362.2 plus or minus 3.3 kJmol(sup -1) and 367.8 plus or minus 1.1 kJmol(sup -1), respectively. This 5 kJmol-1 discrepancy is transferred directly to the measured activities. This is unacceptable and the source of this discrepancy needs to be understood and corrected. Accepting the 2nd law value increases p(Au) by about 50 percent, brings the 2nd and 3rd law values into agreement and removes the T dependence in the 3rd law values. While compelling, there is no way to independently determine instrument sensitivities, S(sub Au), with T in a single experiment with KEMS. This lack of capability is stopping a deeper understanding of this problem. In addition, the Au-C phase diagram suggests a eutectic invariant reaction: L-Au(4.7at%C) = FCC-Au(0.08at%C) + C(graphite) at T(sub e) approximately 1323K. This high C concentration in Au(l) must reduce p(Au) in equilibrium with {Au(s,l) + graphite} and raises some critical questions about the Gibbs free energy functions of Au(s,l) and the Au fixed point (T(sub mp)(Au) = 1337.33K) which is always measured in graphite.

  7. Grafting 3-mercaptopropyl trimethoxysilane on multi-walled carbon nanotubes surface for improving on-line cadmium(II) preconcentration from water samples.

    PubMed

    Corazza, Marcela Zanetti; Somera, Bruna Fabrin; Segatelli, Mariana Gava; Tarley, Cesar Ricardo Teixeira

    2012-12-01

    In the present study, the performance of multi-walled carbon nanotubes (MWCNTs) grafted with 3-mercaptopropyltrimethoxysilane (3-MPTMS), used as a solid phase extractor for Cd(2+) preconcentration in a flow injection system coupled to flame atomic absorption spectrometry (FAAS), was evaluated. The procedure involved the preconcentration of 20.0 mL of Cd(2+) solution at pH 7.5 (0.1 mol L(-1) buffer phosphate) through 70 mg of 3-MPTMS-grafted MWCNTs packed into a minicolumn at 6.0 mL min(-1). The elution step was carried out with 1.0 mol L(-1) HCl. Fourier transform infrared (FTIR) spectroscopy, scanning electron microscopy (SEM) and energy dispersive spectroscopy (EDS) were used to estimate the extent of the MWCNT chemical modification. The 3-MPTMS-grafted MWCNTs provided a 1.68 times improvement in the sensitivity of the Cd(2+) FAAS determination compared to the unsilanized oxidized MWCNTs. The following parameters were obtained: preconcentration factor of 31.5, consumptive index of 0.635 mL, sample throughput of 14 h(-1), and concentration efficiency of 9.46 min(-1). The analytical curve was constructed in the range of 1.0-60.0 μg L(-1) (r=0.9988), and the detection and quantification limits were found to be 0.15 μg L(-1) and 0.62 μg L(-1), respectively. Different types of water samples and cigarette sample were successfully analyzed, and the results were compared using electrothermal atomic absorption spectrometry (ETAAS) as reference technique. In addition, the accuracy of proposed method was also checked by analysis of certified reference material NIST SRM 1573a (tomato leaves) and standard reference material NIST SRM 1643e (trace elements in natural waters). Copyright © 2012 Elsevier B.V. All rights reserved.

  8. Accuracy evaluation of contour next compared with five blood glucose monitoring systems across a wide range of blood glucose concentrations occurring in a clinical research setting.

    PubMed

    Klaff, Leslie J; Brazg, Ronald; Hughes, Kristen; Tideman, Ann M; Schachner, Holly C; Stenger, Patricia; Pardo, Scott; Dunne, Nancy; Parkes, Joan Lee

    2015-01-01

    This study evaluated the accuracy of Contour(®) Next (CN; Bayer HealthCare LLC, Diabetes Care, Whippany, NJ) compared with five blood glucose monitoring systems (BGMSs) across a wide range of clinically occurring blood glucose levels. Subjects (n=146) were ≥ 18 years and had type 1 or type 2 diabetes. Subjects' glucose levels were safely lowered or raised to provide a wide range of glucose values. Capillary blood samples were tested on six BGMSs and a YSI glucose analyzer (YSI Life Sciences, Inc., Yellow Springs, OH) as the reference. Extreme glucose values were achieved by glucose modification of the blood sample. System accuracy was assessed by mean absolute difference (MAD) and mean absolute relative difference (MARD) across several glucose ranges, with <70 mg/dL evaluated by MAD as the primary end point. In the low glucose range (<70 mg/dL), MAD values were as follows: Accu-Chek(®) Aviva Nano (Roche Diagnostics, Indianapolis, IN), 3.34 mg/dL; CN, 2.03 mg/dL; FreeStyle Lite(®) (FSL; Abbott Diabetes Care, Inc., Alameda, CA), 2.77 mg/dL; OneTouch(®) Ultra(®) 2 (LifeScan, Inc., Milpitas, CA), 10.20 mg/dL; OneTouch(®) Verio(®) Pro (LifeScan, Inc.), 4.53 mg/dL; and Truetrack(®) (Nipro Diagnostics, Inc., Fort Lauderdale, FL), 11.08 mg/dL. The lowest MAD in the low glucose range, from CN, was statistically significantly lower than those of the other BGMSs with the exception of the FSL. CN also had a statistically significantly lower MARD than all other BGMSs in the low glucose range. In the overall glucose range (21-496 mg/dL), CN yielded the lowest MAD and MARD values, which were statistically significantly lower in comparison with the other BGMSs. When compared with other BGMSs, CN demonstrated the lowest mean deviation from the reference value (by MAD and MARD) across multiple glucose ranges.

  9. Demonstration of near real-time Sentinel-2A Landsat-8 registration

    NASA Astrophysics Data System (ADS)

    Yan, L.; Roy, D. P.; Huang, H.; Li, Z.; Zhang, H.

    2017-12-01

    The potential for near daily global medium-spatial-resolution optical wavelength remote sensing has been advanced by the availability of European Space Agency (ESA) Sentinel-2 data. Sentinel-2A (S2A) and Landsat-8 (L8) are known to have systematic misregistration errors due to factors including a Landsat geolocation reference discrepancy and a S2A satellite yaw orientation knowledge error (rectified in the recent S2A processing baseline V02.04). In order to undertake low temporal latency applications, such as change detection, near real-time sensor data registration is required. This study considered 2,459 S2A L1C tile images and 355 L8 Collection-1 images defined in UTM zone 35 acquired June to November 2016 over 700 × 1,200 km of Southern Africa. Misregistration characterizations among the S2A L1C tile time series and then among the Landsat-8 Collection-1 time series are first reported. Image matching was undertaken between near-infrared S2A 10 m image pairs and L8 image pairs (resampled to 10 m) using a recently published hierarchical image pyramid approach. The S2A V02.04 products had a 0.45 pixel (10 m) mean intra-misregistration, while the L8 Collection-1 images had a 0.12 pixel (10 m) mean intra-misregistration. Given these findings, we choose to register the S2A to the L8 data. Rather than registering individual images, which is not always robust to missing data, clouds or land surface changes, whole orbits falling over the same UTM zone were registered. A least-squares adjustment was applied using match points between S2A orbit images and L8 images as observations. Each orbit of S2A images was mached to multiple spatially-overlapping and contemporaneous L8 images to generate affine transformation coefficients for its registration. This provided a registered S2A and L8 time series with 0.3 pixel (10 m) misregistration (2σ) and demonstrates a near real-time methodology that can be applied as new sensor data are collected.

  10. Spontaneous T-cell responses against the immune check point programmed-death-ligand 1 (PD-L1) in patients with chronic myeloproliferative neoplasms correlate with disease stage and clinical response.

    PubMed

    Holmström, Morten Orebo; Riley, Caroline Hasselbalch; Skov, Vibe; Svane, Inge Marie; Hasselbalch, Hans Carl; Andersen, Mads Hald

    2018-01-01

    The Chronic Myeloproliferative Neoplasms (MPN) are cancers characterized by hyperinflammation and immune deregulation. Concurrently, the expression of the immune check point programmed death ligand 1 (PD-L1) is induced by inflammation. In this study we report on the occurrence of spontaneous T cell responses against a PD-L1 derived epitope in patients with MPN. We show that 71% of patients display a significant immune response against PD-L1, and patients with advanced MPN have significantly fewer and weaker PD-L1 specific immune responses compared to patients with non-advanced MPN. The PD-L1 specific T cell responses are CD4 + T cell responses, and by gene expression analysis we show that expression of PD-L1 is enhanced in patients with MPN. This could imply that the tumor specific immune response in MPN could be enhanced by vaccination with PD-L1 derived epitopes by boosting the anti-regulatory immune response hereby allowing tumor specific T cell to exert anti-tumor immunity.

  11. Access to Mars from Earth-Moon Libration Point Orbits:. [Manifold and Direct Options

    NASA Technical Reports Server (NTRS)

    Kakoi, Masaki; Howell, Kathleen C.; Folta, David

    2014-01-01

    This investigation is focused specifically on transfers from Earth-Moon L(sub 1)/L(sub 2) libration point orbits to Mars. Initially, the analysis is based in the circular restricted three-body problem to utilize the framework of the invariant manifolds. Various departure scenarios are compared, including arcs that leverage manifolds associated with the Sun-Earth L(sub 2) orbits as well as non-manifold trajectories. For the manifold options, ballistic transfers from Earth-Moon L(sub 2) libration point orbits to Sun-Earth L(sub 1)/L(sub 2) halo orbits are first computed. This autonomous procedure applies to both departure and arrival between the Earth-Moon and Sun-Earth systems. Departure times in the lunar cycle, amplitudes and types of libration point orbits, manifold selection, and the orientation/location of the surface of section all contribute to produce a variety of options. As the destination planet, the ephemeris position for Mars is employed throughout the analysis. The complete transfer is transitioned to the ephemeris model after the initial design phase. Results for multiple departure/arrival scenarios are compared.

  12. L1 Transfer in Article Selection for Generic Reference by Spanish, Turkish and Japanese L2 Learners

    ERIC Educational Resources Information Center

    Snape, Neal; García-Mayo, Maria Del Pilar; Gurel, Ayse

    2013-01-01

    This study examines second language (L2) acquisition of English generic noun phrases (NPs) by Spanish, Turkish and Japanese learners. The aim is to identify the role of the first language (L1) in the L2 acquisition of definite NP-level generics and indefinite sentence-level generics with singular, bare plural, and mass generic nouns. The four…

  13. Datum maintenance of the main Egyptian geodetic control networks by utilizing Precise Point Positioning "PPP" technique

    NASA Astrophysics Data System (ADS)

    Rabah, Mostafa; Elmewafey, Mahmoud; Farahan, Magda H.

    2016-06-01

    A geodetic control network is the wire-frame or the skeleton on which continuous and consistent mapping, Geographic Information Systems (GIS), and surveys are based. Traditionally, geodetic control points are established as permanent physical monuments placed in the ground and precisely marked, located, and documented. With the development of satellite surveying methods and their availability and high degree of accuracy, a geodetic control network could be established by using GNSS and referred to an international terrestrial reference frame used as a three-dimensional geocentric reference system for a country. Based on this concept, in 1992, the Egypt Survey Authority (ESA) established two networks, namely High Accuracy Reference Network (HARN) and the National Agricultural Cadastral Network (NACN). To transfer the International Terrestrial Reference Frame to the HARN, the HARN was connected with four IGS stations. The processing results were 1:10,000,000 (Order A) for HARN and 1:1,000,000 (Order B) for NACN relative network accuracy standard between stations defined in ITRF1994 Epoch1996. Since 1996, ESA did not perform any updating or maintaining works for these networks. To see how non-performing maintenance degrading the values of the HARN and NACN, the available HARN and NACN stations in the Nile Delta were observed. The Processing of the tested part was done by CSRS-PPP Service based on utilizing Precise Point Positioning "PPP" and Trimble Business Center "TBC". The study shows the feasibility of Precise Point Positioning in updating the absolute positioning of the HARN network and its role in updating the reference frame (ITRF). The study also confirmed the necessity of the absent role of datum maintenance of Egypt networks.

  14. Estimate of serum immunoglobulin G concentration using refractometry with or without caprylic acid fractionation.

    PubMed

    Morrill, K M; Polo, J; Lago, A; Campbell, J; Quigley, J; Tyler, H

    2013-07-01

    Objectives of this study were to develop a rapid calf-side test to determine serum IgG concentrations using caprylic acid (CA) fractionation, followed by refractometry of the IgG-rich supernatant and compare the accuracy of this method with results obtained using refractometry using raw serum. Serum samples (n=200) were obtained from 1-d-old calves, frozen (-20°C), and shipped to the laboratory. Samples were allowed to thaw for 1h at room temperature. Fractionation with CA was conducted by adding 1mL of serum to a tube containing 45, 60, or 75µL of CA and 0.5, 1.0, or 1.5mL of 0.06 M acetic acid. The tube contents were mixed well, allowed to react for 1 min, and then centrifuged at 3,300 × g for 0, 10, or 20 min at 25°C. The %Brix and refractive index of the fractionated supernatant were determined using a digital refractometer. Nonfractionated serum was analyzed for %Brix (BRn), refractive index (nDn), and IgG concentration by radial immunodiffusion. The mean serum IgG concentration was 19.0 mg/mL [standard deviation (SD)=9.7], with a range of 3.5 to 47.0 mg/mL. The mean serum BRn was 8.6 (SD=0.91), with a range of 6.8 to 11.0. The mean serum nDn was 1.34566 (SD=0.00140), with a range of 1.34300 to 1.34930. Serum nDn was positively correlated with IgG concentration (correlation coefficient=0.86; n=185). Fractionated samples treated with 1mL 0.6 M acetic acid and 60µL of CA and not centrifuged before analysis resulted in a strong relationship between the refractive index of the fractionated supernatant and IgG (correlation coefficient=0.80; n=45). Regression was used to determine cut points indicative of 10, 12, and 14 mg of IgG/mL to determine the sensitivity and specificity of refractometry to identify failure of passive transfer (serum IgG <10 mg/mL at 24 h old). The nDn were 1.34414, 1.34448, and 1.34480 to predict 10, 12, and 14 mg of IgG/mL of serum, respectively. The BRn cut points were 7.6, 7.8, and 8.0, respectively. The nDn cut points of 1.34448 and 1.34480 resulted in similar specificities (82.9%), whereas the 1.34414 cut point had a specificity of 60.0%. The BRn cut point of 7.6 and 7.8%Brix resulted in a similar percentage of correctly classified samples (89.7 and 90.8%, respectively); however, the 7.8% Brix cut point resulted in fewer false positives. These results suggest that Brix refractometry of nonfractionated calf serum provides a strong estimate of IgG concentration and 7.8% Brix may be used as the cut point to identify failure of passive transfer in 1-d-old calves. Copyright © 2013 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  15. Influence of guidance concept in complete dentures on oral health related quality of life - Canine guidance vs. bilateral balanced occlusion.

    PubMed

    Schierz, Oliver; Reissmann, Daniel

    2016-10-01

    To compare the impact of canine guided vs. bilateral balanced occlusion on oral health related quality of life (OHRQoL) as a patient-reported outcome measure. In this randomized single-blind crossover trial, 19 patients have been provided with new complete dentures in the maxilla and mandible. OHRQoL was assessed using the 49-item Oral Health Impact Profile (OHIP-49) before the start of the prosthodontic treatment (B), 3 months after insertion of the new dentures (T1), and 3 months after rework into the alternative concept (T2). Multilevel mixed-effect linear regression models were computed to determine the effect provided by the new set of dentures and the specific impact of the occlusal concept on OHRQoL using summary scores of the OHIP-49 and of a 19-items subset specific for edentulous patients (OHIP-EDENT). At baseline, participants' OHRQoL was substantially impaired indicated by an average OHIP-49 score of 42.1 points and an OHIP-EDENT score of 21.1 points. The effect of provision of a new set of complete dentures was a statistically significant decrease of 8.3 points (OHIP-49) and 4.0 points (OHIP-EDENT), respectively, representing a clinically relevant improvement in OHRQoL. When wearing dentures with bilateral balanced occlusion, participants showed on average 1.6 points higher OHIP-49 scores and 0.9 points higher OHIP-EDENT scores compared to canine guided dentures. This effect of the occlusal concept was neither statistically nor clinically significant. Both investigated occlusal concepts for complete dentures were comparable in their effect on patients' perceptions with none being considerably superior in terms of OHRQoL. Copyright © 2016 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

  16. beta. -Adrenoceptors in human tracheal smooth muscle: characteristics of binding and relaxation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    van Koppen, C.J.; Hermanussen, M.W.; Verrijp, K.N.

    1987-06-29

    Specific binding of (/sup 125/I)-(-)-cyanopindolol to human tracheal smooth muscle membranes was saturable, stereo-selective and of high affinity (K/sub d/ = 5.3 +/- 0.9 pmol/l and R/sub T/ = 78 +/- 7 fmol/g tissue). The ..beta../sub 1/-selective antagonists atenolol and LK 203-030 inhibited specific (/sup 125/I)-(-)-cyanopindolol binding according to a one binding site model with low affinity in nearly all subjects, pointing to a homogeneous BETA/sub 2/-adrenoceptor population. In one subject using LK 203-030 a small ..beta../sub 1/-adrenoceptor subpopulation could be demonstrated. The beta-mimetics isoprenaline, fenoterol, salbutamol and terbutaline recognized high and low affinity agonist binding sites. Isoprenaline's pK/sub H/-more » and pK/sub L/-values for the high and low affinity sites were 8.0 +/- 0.2 and 5.9 +/- 0.3 respectively. In functional experiments isoprenaline relaxed tracheal smooth muscle strips having intrinsic tone with a pD/sub 2/-value of 6.63 +/- 0.19. 32 references, 4 figures, 2 tables.« less

  17. A new method of UA_CPE coupled with spectrophotometry for the faster and cost-effective detection of proline in fruit juice, honey, and wine.

    PubMed

    Dağdeviren, Semahat; Altunay, Nail; Sayman, Yasin; Gürkan, Ramazan

    2018-07-30

    The study developed a new method for proline detection in honey, wine and fruit juice using ultrasound assisted-cloud point extraction (UA-CPE) and spectrophotometry. Initially, a quaternary complex was built, containing proline, histamine, Cu(II), and fluorescein at pH 5.5. Samples were treated with ethanol-water mixture before extraction and preconcentration, using an ultrasonic bath for 10 min at 40 °C (40 kHz, 300 W). After the optimization of variables affecting extraction efficiency, good linearity was obtained between 15 and 600 µg L -1 with sensitivity enhancement factor of 105. The limits of detection and quantification were 5.7 and 19.0 µg L -1 , respectively. The recovery percentage and relative standard deviations (RSD %) were between 95.3 and 103.3%, and 2.5 and 4.2%, respectively. The accuracy of the method was verified by the analysis of a standard reference material (SRM 2389a). Copyright © 2018 Elsevier Ltd. All rights reserved.

  18. Performance Evaluation and Control of Distributed Computer Communication Networks.

    DTIC Science & Technology

    1984-09-01

    including: L. Clare, L.A. De Moraes, J. Baker, M. Zuckerman, S. Katz, P. Rodrigues, R. Pazos , S. Resheff. Other participants are the following visiting...investigations have been reported in reference (1) and (2) below. References (1) M. Gerla, R. Pazos -Rangel "Bandwidth Allocation and Routing in ISDN’s," IEEE...and efficient methods for its solution are presented. (2) R.A. Pazos -Rangel "Evaluation and Design of Integrated Packet Switching and Circuit Switching

  19. Sharing reference data and including cows in the reference population improve genomic predictions in Danish Jersey.

    PubMed

    Su, G; Ma, P; Nielsen, U S; Aamand, G P; Wiggans, G; Guldbrandtsen, B; Lund, M S

    2016-06-01

    Small reference populations limit the accuracy of genomic prediction in numerically small breeds, such like Danish Jersey. The objective of this study was to investigate two approaches to improve genomic prediction by increasing size of reference population in Danish Jersey. The first approach was to include North American Jersey bulls in Danish Jersey reference population. The second was to genotype cows and use them as reference animals. The validation of genomic prediction was carried out on bulls and cows, respectively. In validation on bulls, about 300 Danish bulls (depending on traits) born in 2005 and later were used as validation data, and the reference populations were: (1) about 1050 Danish bulls, (2) about 1050 Danish bulls and about 1150 US bulls. In validation on cows, about 3000 Danish cows from 87 young half-sib families were used as validation data, and the reference populations were: (1) about 1250 Danish bulls, (2) about 1250 Danish bulls and about 1150 US bulls, (3) about 1250 Danish bulls and about 4800 cows, (4) about 1250 Danish bulls, 1150 US bulls and 4800 Danish cows. Genomic best linear unbiased prediction model was used to predict breeding values. De-regressed proofs were used as response variables. In the validation on bulls for eight traits, the joint DK-US bull reference population led to higher reliability of genomic prediction than the DK bull reference population for six traits, but not for fertility and longevity. Averaged over the eight traits, the gain was 3 percentage points. In the validation on cows for six traits (fertility and longevity were not available), the gain from inclusion of US bull in reference population was 6.6 percentage points in average over the six traits, and the gain from inclusion of cows was 8.2 percentage points. However, the gains from cows and US bulls were not accumulative. The total gain of including both US bulls and Danish cows was 10.5 percentage points. The results indicate that sharing reference data and including cows in reference population are efficient approaches to increase reliability of genomic prediction. Therefore, genomic selection is promising for numerically small population.

  20. The research of the coupled orbital-attitude controlled motion of celestial body in the neighborhood of the collinear libration point L1

    NASA Astrophysics Data System (ADS)

    Shmyrov, A.; Shmyrov, V.; Shymanchuk, D.

    2017-10-01

    This article considers the motion of a celestial body within the restricted three-body problem of the Sun-Earth system. The equations of controlled coupled attitude-orbit motion in the neighborhood of collinear libration point L1 are investigated. The translational orbital motion of a celestial body is described using Hill's equations of circular restricted three-body problem of the Sun-Earth system. Rotational orbital motion is described using Euler's dynamic equations and quaternion kinematic equation. We investigate the problem of stability of celestial body rotational orbital motion in relative equilibrium positions and stabilization of celestial body rotational orbital motion with proposed control laws in the neighborhood of collinear libration point L1. To study stabilization problem, Lyapunov function is constructed in the form of the sum of the kinetic energy and special "kinematic function" of the Rodriguez-Hamiltonian parameters. Numerical modeling of the controlled rotational motion of a celestial body at libration point L1 is carried out. The numerical characteristics of the control parameters and rotational motion are given.

  1. 42 CFR 494.40 - Condition: Water and dialysate quality.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... the port of the initial component or carbon tank referred to in section 6.2.5 of AAMI RD52:2004 are greater than 0.5 mg/L for free chlorine or 0.1 mg/L for chloramines, or equal to or greater than 0.1 mg/L...

  2. 42 CFR 494.40 - Condition: Water and dialysate quality.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... the port of the initial component or carbon tank referred to in section 6.2.5 of AAMI RD52:2004 are greater than 0.5 mg/L for free chlorine or 0.1 mg/L for chloramines, or equal to or greater than 0.1 mg/L...

  3. Walking ability and quality of life in subjects with transfemoral amputation: a comparison of osseointegration with socket prostheses.

    PubMed

    Van de Meent, Hendrik; Hopman, Maria T; Frölke, Jan Paul

    2013-11-01

    To investigate walking ability and quality of life of osseointegrated leg prostheses compared with socket prostheses. Prospective case-control study. University medical center. Subjects (N=22) with transfemoral amputation (1 bilateral) referred to our center because of socket-related skin and residual limb problems resulting in limited prosthesis use. Their mean age was 46.5 years (range, 23-67y) and mean time since amputation was 16.4 years (range, 2-45y). Causes of amputation were trauma (n=20) and tumor (n=2). Implantation of an osseointegration prosthesis (OIP). Global score of the Questionnaire for Persons With a Transfemoral Amputation (Q-TFA), prosthesis use, 6-minute walk test (6MWT), Timed Up & Go (TUG) test, and oxygen consumption during treadmill walking. With the socket prosthesis, the mean ± SD Q-TFA global score, prosthesis use, 6MWT, TUG, and oxygen consumption were 39±4.7 points, 56±7.9h/wk, 321±28m, 15.1±2.1 seconds, and 1330±310mL/min, respectively, and significantly improved with OIP to 63±5.3 points, 101±2.4h/wk, 423±21m, 8.1±0.7 seconds, and 1093±361mL/min, respectively. Osseointegration is a suitable intervention for persons whose prosthesis use is reduced because of socket-related problems. Subjects with OIP significantly increased their walking ability and prosthesis-related quality of life. Copyright © 2013 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  4. Analysis of Rail Gun Bore Residue

    DTIC Science & Technology

    1984-03-01

    erosion effects and elemental analysis of refractory materials. C. A. L. Westerdahl , J. Pinto, G. L. Ferventino, D. N. Saherhavth...accelerator facility at Large Caliber Weapons Systems Laboratory Dover, New Jersey. ’ 16 REFERENCES 1. C.A.L. Westerdahl , J. Pinto, G. L. Ferrentino, D

  5. Using Solar Radiation Pressure to Control L2 Orbits

    NASA Technical Reports Server (NTRS)

    Tene, Noam; Richon, Karen; Folta, David

    1998-01-01

    The main perturbations at the Sun-Earth Lagrange points L1 and L2 are from solar radiation pressure (SRP), the Moon and the planets. Traditional approaches to trajectory design for Lagrange-point orbits use maneuvers every few months to correct for these perturbations. The gravitational effects of the Moon and the planets are small and periodic. However, they cannot be neglected because small perturbations in the direction of the unstable eigenvector are enough to cause exponential growth within a few months. The main effect of a constant SRP is to shift the center of the orbit by a small distance. For spacecraft with large sun-shields like the Microwave Anisotropy Probe (MAP) and the Next Generation Space Telescope (NGST), the SRP effect is larger than all other perturbations and depends mostly on spacecraft attitude. Small variations in the spacecraft attitude are large enough to excite or control the exponential eigenvector. A closed-loop linear controller based on the SRP variations would eliminate one of the largest errors to the orbit and provide a continuous acceleration for use in controlling other disturbances. It is possible to design reference trajectories that account for the periodic lunar and planetary perturbations and still satisfy mission requirements. When such trajectories are used the acceleration required to control the unstable eigenvector is well within the capabilities of a continuous linear controller. Initial estimates show that by using attitude control it should be possible to minimize and even eliminate thruster maneuvers for station keeping.

  6. Syntheses, structures and luminescence for zinc coordination polymers based on a multifunctional 4‧-(3-carboxyphenyl)- 3,2‧:6‧,3″-terpyridine ligand

    NASA Astrophysics Data System (ADS)

    Cheng, Yue; Yang, Meng-Lin; Hu, Huai-Ming; Xu, Bing; Wang, Xiaofang; Xue, Ganglin

    2016-07-01

    Six new coordination polymers, [ZnLCl]n(1), [ZnL2]n·2nH2O (2), [Zn2L(o-bdc)(OH)]n·0.5nH2O (3), [Zn2L(m-bdc)(OH)]n·nH2O (4), [Zn2L2(p-bdc) (H2O)2]n·nH2O (5), [Zn2L(1,2,4-btc)(H2O)]n(6), (HL=4‧-(3-carboxyphenyl)- 3,2‧:6‧,3″-terpyridine, H2(o-bdc)= benzene-1,2-dicarboxylic acid, H2(m-bdc)= benzene-1,3-dicarboxylic acid, H2(p-bdc)= benzene-1,4-dicarboxylic acid, H3(1,2,4-btc)= benzene-1,2,4-tricarboxylic acid) have been synthesized under the hydrothermal conditions. Compound 1 displays a 3-connected 2D network structure with point symbol of {82.10}. Compound 2 exhibits 1D infinite loop chain structure. Compound 3 possesses a (3,8)-connected 3D framework composed of tetranuclear units with point symbol of {43}2{46.618.84}. Compound 4 features a typical 2D hcb network based on tetranuclear zinc(II) units with point symbol of {44.62}. Compound 5 presents a classical two-fold penetration sql network with point symbol of {63}. Compound 6 can be seen as a (3,3,6)-connected 3D net with point symbol of {42.64.89}{42.6}{63}. The thermal stability and luminescent properties of compounds 1-6 in the solid state are discussed in detail.

  7. PLUME-FEATHER, Referencing and Finding Software for Research and Education

    NASA Astrophysics Data System (ADS)

    Bénassy, O.; Caron, C.; Ferret-Canape, C.; Cheylus, A.; Courcelle, E.; Dantec, C.; Dayre, P.; Dostes, T.; Durand, A.; Facq, A.; Gambini, G.; Geahchan, E.; Helft, C.; Hoffmann, D.; Ingarao, M.; Joly, P.; Kieffer, J.; Larré, J.-M.; Libes, M.; Morris, F.; Parmentier, H.; Pérochon, L.; Porte, O.; Romier, G.; Rousse, D.; Tournoy, R.; Valeins, H.

    2014-06-01

    PLUME-FEATHER is a non-profit project created to Promote economicaL, Useful and Maintained softwarEFor theHigher Education And THE Research communities. The site references software, mainly Free/Libre Open Source Software (FLOSS) from French universities and national research organisations, (CNRS, INRA...), laboratories or departments as well as other FLOSS software used and evaluated by users within these institutions. Each software is represented by a reference card, which describes origin, aim, installation, cost (if applicable) and user experience from the point of view of an academic user for academic users. Presently over 1000 programs are referenced on PLUME by more than 900 contributors. Although the server is maintained by a French institution, it is open to international contributions in the academic domain. All contained and validated contents are visible to anonymous public, whereas (presently more than 2000) registered users can contribute, starting with comments on single software reference cards up to help with the organisation and presentation of the referenced software products. The project has been presented to the HEP community in 2012 for the first time [1]. This is an update of the status and a call for (further) contributions.

  8. Iconicity and Sign Lexical Acquisition: A Review

    PubMed Central

    Ortega, Gerardo

    2017-01-01

    The study of iconicity, defined as the direct relationship between a linguistic form and its referent, has gained momentum in recent years across a wide range of disciplines. In the spoken modality, there is abundant evidence showing that iconicity is a key factor that facilitates language acquisition. However, when we look at sign languages, which excel in the prevalence of iconic structures, there is a more mixed picture, with some studies showing a positive effect and others showing a null or negative effect. In an attempt to reconcile the existing evidence the present review presents a critical overview of the literature on the acquisition of a sign language as first (L1) and second (L2) language and points at some factor that may be the source of disagreement. Regarding sign L1 acquisition, the contradicting findings may relate to iconicity being defined in a very broad sense when a more fine-grained operationalisation might reveal an effect in sign learning. Regarding sign L2 acquisition, evidence shows that there is a clear dissociation in the effect of iconicity in that it facilitates conceptual-semantic aspects of sign learning but hinders the acquisition of the exact phonological form of signs. It will be argued that when we consider the gradient nature of iconicity and that signs consist of a phonological form attached to a meaning we can discern how iconicity impacts sign learning in positive and negative ways. PMID:28824480

  9. Correlation between solar flare productivity and photospheric vector magnetic fields

    NASA Astrophysics Data System (ADS)

    Cui, Yanmei; Wang, Huaning

    2008-11-01

    Studying the statistical correlation between the solar flare productivity and photospheric magnetic fields is very important and necessary. It is helpful to set up a practical flare forecast model based on magnetic properties and improve the physical understanding of solar flare eruptions. In the previous study ([Cui, Y.M., Li, R., Zhang, L.Y., He, Y.L., Wang, H.N. Correlation between solar flare productivity and photospheric magnetic field properties 1. Maximum horizontal gradient, length of neutral line, number of singular points. Sol. Phys. 237, 45 59, 2006]; from now on we refer to this paper as ‘Paper I’), three measures of the maximum horizontal gradient, the length of the neutral line, and the number of singular points are computed from 23990 SOHO/MDI longitudinal magnetograms. The statistical relationship between the solar flare productivity and these three measures is well fitted with sigmoid functions. In the current work, the three measures of the length of strong-shear neutral line, total unsigned current, and total unsigned current helicity are computed from 1353 vector magnetograms observed at Huairou Solar Observing Station. The relationship between the solar flare productivity and the current three measures can also be well fitted with sigmoid functions. These results are expected to be beneficial to future operational flare forecasting models.

  10. Measurement of cardiac troponin I utilizing a point of care analyzer in healthy alpacas.

    PubMed

    Blass, Keith A; Kraus, Marc S; Rishniw, Mark; Mann, Sabine; Mitchell, Lisa M; Divers, Thomas J

    2011-12-01

    Myocardial disease in camelids is poorly characterized. Nutritional (selenium deficiency) and toxic (ionophore toxicity) myocardial disease have been reported in camelids. Diagnosis and management of these and other myocardial diseases might be enhanced by evaluating cardiac troponin I (cTnI) concentrations. No information about cTnI reference intervals in camelids is currently available. (A) To determine cTnI concentrations obtained using a point of care i-STAT(®)1 analyzer (Heska Corporation) in healthy alpacas; (B) to compare alpaca cTnI concentrations between heparinized whole blood and plasma samples and between 2 different storage conditions (4 °C for 24 h or -80 °C for 30 days); (C) to examine assay reproducibility using the i-STAT(®)1. 23 healthy alpacas were evaluated. Blood and plasma samples were analyzed by the i-STAT(®)1 within 1 h of collection. Aliquots of plasma were stored at either 4 °C for 24 h or -80 °C for 30 days, and then analyzed. Assay reproducibility was determined by comparing 2 plasma or whole blood cTnI concentrations measured on the same sample over a 10 min period. Analyzer-specific plasma cTnI concentrations in clinically normal alpacas had a median of <0.02 ng/mL (range: <0.02 ng/mL to 0.07 ng/mL). Plasma and whole blood concentrations showed good agreement. Storage did not affect cTnI concentrations (p > 0.75). Plasma cTnI concentrations had coefficient of repeatability of 0.02 ng/mL. The i-STAT(®)1 can measure cTnI in alpacas on both plasma and whole blood and provides similar values for both samples. Storage at 4 °C for 24 h or -80 °C for 30 days does not affect estimates of plasma cTnI. Evaluation of cTnI might be of value in assessing cardiac disease in this species. Copyright © 2011 Elsevier B.V. All rights reserved.

  11. 46 CFR 160.005-1 - Incorporation by reference.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... makes reference to the following documents: (1) Federal Specification: L-P-375C—Plastic Film, Flexible....005-1: (Sheet 1) Cutting Pattern and General Arrangement (Adult). (Sheet 2) Alternate Stitching of Tapes and Webbing (Adult and Child). (Sheet 3) Pad Detail (Adult). (Sheet 4) Cutting Pattern and General...

  12. 46 CFR 160.005-1 - Incorporation by reference.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... makes reference to the following documents: (1) Federal Specification: L-P-375C—Plastic Film, Flexible....005-1: (Sheet 1) Cutting Pattern and General Arrangement (Adult). (Sheet 2) Alternate Stitching of Tapes and Webbing (Adult and Child). (Sheet 3) Pad Detail (Adult). (Sheet 4) Cutting Pattern and General...

  13. 46 CFR 160.005-1 - Incorporation by reference.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... makes reference to the following documents: (1) Federal Specification: L-P-375C—Plastic Film, Flexible....005-1: (Sheet 1) Cutting Pattern and General Arrangement (Adult). (Sheet 2) Alternate Stitching of Tapes and Webbing (Adult and Child). (Sheet 3) Pad Detail (Adult). (Sheet 4) Cutting Pattern and General...

  14. 46 CFR 160.005-1 - Incorporation by reference.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... makes reference to the following documents: (1) Federal Specification: L-P-375C—Plastic Film, Flexible....005-1: (Sheet 1) Cutting Pattern and General Arrangement (Adult). (Sheet 2) Alternate Stitching of Tapes and Webbing (Adult and Child). (Sheet 3) Pad Detail (Adult). (Sheet 4) Cutting Pattern and General...

  15. Biochemical and hematological changes following the 120-km open-water marathon swim.

    PubMed

    Drygas, Wojciech; Rębowska, Ewa; Stępień, Ewa; Golański, Jacek; Kwaśniewska, Magdalena

    2014-09-01

    Data on physiological effects and potential risks of a ultraendurance swimming are scarce. This report presents the unique case of a 61-year old athlete who completed a non-stop open-water 120-km ultramarathon swim on the Warta River, Poland. Pre-swimming examinations revealed favorable conditions (blood pressure, 110/70 mmHg; rest heart rate, 54 beats/minute, ejection fraction, 60%, 20.2 metabolic equivalents in a maximal exercise test). The swimming time and distance covered were 27 h 33 min and 120 km, respectively. Blood samples for hematological and biochemical parameters were collected 30 min, 4 hrs, 10 hrs and 8 days after the swim. The body temperature of the swimmer was 36.7°C before and 35.1°C after the swim. The hematological parameters remained within the reference range in the postexercise period except for leucocytes (17.5 and 10.6 x G/l noted 30 minutes and 4 hours after the swim, respectively). Serum urea, aspartate aminotransferase and C-reactive protein increased above the reference range reaching 11.3 mmol/l, 1054 nmol/l/s and 25.9 mg/l, respectively. Symptomatic hyponatremia was not observed. Although the results demonstrate that an experienced athlete is able to complete an ultra-marathon swim without negative health consequences, further studies addressing the potential risks of marathon swimming are required. Key pointsData on biochemical changes due to long-distance swimming are scarce.This report presents the unique case of a 61-year old athlete who completed a non-stop open-water 120-km ultramarathon swim.An experienced athlete is able to complete an ultra-marathon swim without serious health consequences.Regarding the growing popularity of marathon swimming further studies addressing the potential risks of such exhaustive exercise are required.

  16. What Analytic Method Should Clinicians Use to Derive Spine T-scores and Predict Incident Fractures in Men? Results from the MrOS study

    PubMed Central

    Hansen, Karen E; Blank, Robert D; Palermo, Lisa; Fink, Howard A; Orwoll, Eric S

    2014-01-01

    Summary In this study, the area under the curve was highest when using the lowest vertebral body T-score to diagnose osteoporosis. In men for whom hip imaging is not possible, the lowest vertebral body T-score improves ability to diagnose osteoporosis in men who are likely to have an incident fragility fracture. Purpose Spine T-scores have limited ability to predict fragility fracture. We hypothesized that using lowest vertebral body T-score to diagnose osteoporosis would better predict fracture. Methods Among men enrolled in the Osteoporotic Fractures in Men Study, we identified cases with incident clinical fracture (n=484) and controls without fracture (n=1,516). We analyzed the lumbar spine BMD in cases and controls (n=2,000) to record the L1-L4 (referent), the lowest vertebral body and ISCD-determined T-scores using a male normative database, and the L1-L4 T-score using a female normative database. We compared the ability of method to diagnose osteoporosis and therefore predict incident clinical fragility fracture, using area under the receiver operator curves (AUC) and the net reclassification index (NCI) as measures of diagnostic accuracy. ISCD-determined T-scores were determined in only 60% of participants (n=1205). Results Among 1,205 men, the AUC to predict incident clinical fracture was 0.546 for L1-L4 male, 0.542 for the L1-L4 female, 0.585 for lowest vertebral body and 0.559 for ISCD-determined T-score. The lowest vertebral body AUC was the only method significantly different from the referent method (p=0.002). Likewise, a diagnosis of osteoporosis based on the lowest vertebral body T-score demonstrated a significantly better NRI than the referent method (net NRI +0.077, p=0.005). By contrast, the net NRI for other methods of analysis did not differ from the referent method. Conclusion Our study suggests that in men, the lowest vertebral body T-score is an acceptable method by which to estimate fracture risk. PMID:24850381

  17. Utility of ultrasound assisted-cloud point extraction and spectophotometry as a preconcentration and determination tool for the sensitive quantification of mercury species in fish samples

    NASA Astrophysics Data System (ADS)

    Altunay, Nail

    2018-01-01

    The current study reports, for the first time, the development of a new analytical method employing ultrasound assisted-cloud point extraction (UA-CPE) for the extraction of CH3Hg+ and Hg2 + species from fish samples. Detection and quantification of mercury species were performed at 550 nm by spectrophotometry. The analytical variables affecting complex formation and extraction efficiency were extensively evaluated and optimized by univariate method. Due to behave 14-fold more sensitive and selective of thiophene 2,5-dicarboxylic acid (H2TDC) to Hg2 + ions than CH3Hg+ in presence of mixed surfactant, Tween 20 and SDS at pH 5.0, the amounts of free Hg2 + and total Hg were spectrophotometrically established at 550 nm by monitoring Hg2 + in the pretreated- and extracted-fish samples in ultrasonic bath to speed up extraction using diluted acid mixture (1:1:1, v/v, 4 mol L- 1 HNO3, 4 mol L- 1 HCl, and 0.5 mol L- 1 H2O2), before and after pre-oxidation with permanganate in acidic media. The amount of CH3Hg+ was calculated from difference between total Hg and Hg2 + amounts. The UA-CPE method showed to be suitable for the extraction and determination of mercury species in certified reference materials. The results were in a good agreement (with Student's t-test at 95% confidence limit) with the certified values, and the relative standard deviation was lower than 3.2%. The limits of detection have been 0.27 and 1.20 μg L- 1, for Hg2 + from aqueous calibration solutions and matrix-matched calibration solutions spiked before digestion, respectively, while it is 2.43 μg L- 1 for CH3Hg+ from matrix-matched calibration solutions. A significant matrix effect was not observed from comparison of slopes of both calibration curves, so as to represent the sample matrix. The method was applied to fish samples for speciation analysis of Hg2 + and CH3Hg+. In terms of speciation, while total Hg is detected in range of 2.42-32.08 μg kg- 1, the distribution of mercury in fish were in range of 0.7-11.06 μg kg- 1 for CH3Hg+ and in range of 1.72-24.56 μg kg- 1 for Hg2 +.

  18. Spinal pedicle screw planning using deformable atlas registration

    NASA Astrophysics Data System (ADS)

    Goerres, J.; Uneri, A.; De Silva, T.; Ketcha, M.; Reaungamornrat, S.; Jacobson, M.; Vogt, S.; Kleinszig, G.; Osgood, G.; Wolinsky, J.-P.; Siewerdsen, J. H.

    2017-04-01

    Spinal screw placement is a challenging task due to small bone corridors and high risk of neurological or vascular complications, benefiting from precision guidance/navigation and quality assurance (QA). Implicit to both guidance and QA is the definition of a surgical plan—i.e. the desired trajectories and device selection for target vertebrae—conventionally requiring time-consuming manual annotations by a skilled surgeon. We propose automation of such planning by deriving the pedicle trajectory and device selection from a patient’s preoperative CT or MRI. An atlas of vertebrae surfaces was created to provide the underlying basis for automatic planning—in this work, comprising 40 exemplary vertebrae at three levels of the spine (T7, T8, and L3). The atlas was enriched with ideal trajectory annotations for 60 pedicles in total. To define trajectories for a given patient, sparse deformation fields from the atlas surfaces to the input (CT or MR image) are applied on the annotated trajectories. Mean value coordinates are used to interpolate dense deformation fields. The pose of a straight trajectory is optimized by image-based registration to an accumulated volume of the deformed annotations. For evaluation, input deformation fields were created using coherent point drift (CPD) to perform a leave-one-out analysis over the atlas surfaces. CPD registration demonstrated surface error of 0.89  ±  0.10 mm (median  ±  interquartile range) for T7/T8 and 1.29  ±  0.15 mm for L3. At the pedicle center, registered trajectories deviated from the expert reference by 0.56  ±  0.63 mm (T7/T8) and 1.12  ±  0.67 mm (L3). The predicted maximum screw diameter differed by 0.45  ±  0.62 mm (T7/T8), and 1.26  ±  1.19 mm (L3). The automated planning method avoided screw collisions in all cases and demonstrated close agreement overall with expert reference plans, offering a potentially valuable tool in support of surgical guidance and QA.

  19. Spinal pedicle screw planning using deformable atlas registration.

    PubMed

    Goerres, J; Uneri, A; De Silva, T; Ketcha, M; Reaungamornrat, S; Jacobson, M; Vogt, S; Kleinszig, G; Osgood, G; Wolinsky, J-P; Siewerdsen, J H

    2017-04-07

    Spinal screw placement is a challenging task due to small bone corridors and high risk of neurological or vascular complications, benefiting from precision guidance/navigation and quality assurance (QA). Implicit to both guidance and QA is the definition of a surgical plan-i.e. the desired trajectories and device selection for target vertebrae-conventionally requiring time-consuming manual annotations by a skilled surgeon. We propose automation of such planning by deriving the pedicle trajectory and device selection from a patient's preoperative CT or MRI. An atlas of vertebrae surfaces was created to provide the underlying basis for automatic planning-in this work, comprising 40 exemplary vertebrae at three levels of the spine (T7, T8, and L3). The atlas was enriched with ideal trajectory annotations for 60 pedicles in total. To define trajectories for a given patient, sparse deformation fields from the atlas surfaces to the input (CT or MR image) are applied on the annotated trajectories. Mean value coordinates are used to interpolate dense deformation fields. The pose of a straight trajectory is optimized by image-based registration to an accumulated volume of the deformed annotations. For evaluation, input deformation fields were created using coherent point drift (CPD) to perform a leave-one-out analysis over the atlas surfaces. CPD registration demonstrated surface error of 0.89  ±  0.10 mm (median  ±  interquartile range) for T7/T8 and 1.29  ±  0.15 mm for L3. At the pedicle center, registered trajectories deviated from the expert reference by 0.56  ±  0.63 mm (T7/T8) and 1.12  ±  0.67 mm (L3). The predicted maximum screw diameter differed by 0.45  ±  0.62 mm (T7/T8), and 1.26  ±  1.19 mm (L3). The automated planning method avoided screw collisions in all cases and demonstrated close agreement overall with expert reference plans, offering a potentially valuable tool in support of surgical guidance and QA.

  20. Accuracy and coverage of the modernized Polish Maritime differential GPS system

    NASA Astrophysics Data System (ADS)

    Specht, Cezary

    2011-01-01

    The DGPS navigation service augments The NAVSTAR Global Positioning System by providing localized pseudorange correction factors and ancillary information which are broadcast over selected marine reference stations. The DGPS service position and integrity information satisfy requirements in coastal navigation and hydrographic surveys. Polish Maritime DGPS system has been established in 1994 and modernized (in 2009) to meet the requirements set out in IMO resolution for a future GNSS, but also to preserve backward signal compatibility of user equipment. Having finalized installation of the new technology L1, L2 reference equipment performance tests were performed.The paper presents results of the coverage modeling and accuracy measuring campaign based on long-term signal analyses of the DGPS reference station Rozewie, which was performed for 26 days in July 2009. Final results allowed to verify the coverage area of the differential signal from reference station and calculated repeatable and absolute accuracy of the system, after the technical modernization. Obtained field strength level area and position statistics (215,000 fixes) were compared to past measurements performed in 2002 (coverage) and 2005 (accuracy), when previous system infrastructure was in operation.So far, no campaigns were performed on differential Galileo. However, as signals, signal processing and receiver techniques are comparable to those know from DGPS. Because all satellite differential GNSS systems use the same transmission standard (RTCM), maritime DGPS Radiobeacons are standardized in all radio communication aspects (frequency, binary rate, modulation), then the accuracy results of differential Galileo can be expected as a similar to DGPS.Coverage of the reference station was calculated based on unique software, which calculate the signal strength level based on transmitter parameters or field signal strength measurement campaign, done in the representative points. The software works based on Baltic sea vector map, ground electric parameters and models atmospheric noise level in the transmission band.

  1. Reference intervals for serum lipids and prevalence of dyslipidaemia in 6-12-year-old children: The Health Oriented Pedagogical Project (HOPP).

    PubMed

    Strand, Martin Frank; Fredriksen, Per Morten; Hjelle, Ole Petter; Lindberg, Morten

    2018-05-01

    Elevated serum lipid concentrations in childhood are thought to be risk factors for the development of cardiovascular disease later in life. The present study aims to provide age- and gender-related reference intervals for total cholesterol (TC), high-density lipoprotein (HDL) cholesterol, and non-HDL cholesterol in healthy school children. We also investigated the prevalence of dyslipidaemia using the published criteria for these biomarkers. Venous blood and anthropometric data were collected from 1340 children in the HOPP study, aged between 6 and 12 years. Age- and gender-related reference intervals (2.5th and 97.5th percentiles) were established according to the IFCC recommendations, using the software RefVal 4.10. Gender differences were observed for total cholesterol and non-HDL cholesterol, but not for HDL cholesterol. Age differences were observed for total cholesterol. The reference intervals were in the range of 3.1-5.9 mmol/L for total cholesterol, 1.0-2.4 mmol/L for HDL cholesterol and 1.4-4.2 mmol/L for non-HDL cholesterol. Dyslipidaemia prevalence was as follows: increased TC 9.6%, decreased HDL 1.6%, and increased non-HDL 5.6%. Age- and gender-related reference intervals in a Norwegian population are similar to those reported in other countries. The prevalence of dyslipidaemia among Norwegian children is significant, emphasising the importance of appropriate reference intervals in clinical practice.

  2. Pharmacokinetics of propafenone hydrochloride sustained-release capsules in male beagle dogs.

    PubMed

    Pan, Liping; Qian, Yafang; Cheng, Minlu; Gu, Pan; He, Yanna; Xu, Xiaowen; Ding, Li

    2015-01-01

    This paper describes the development and validation of a liquid chromatography-mass spectrometric assay for propafenone and its application to a pharmacokinetic study of propafenone administered as a new propafenone hydrochloride sustained-release capsule (SR-test), as an instant-release tablet (IR-reference) and as the market leader sustained-release capsule (Rythmol, SR-reference) in male beagle dogs (n=8). In Study A comparing SR-test with IR-reference in a crossover design T max and t 1/2 of propafenone for SR-test were significantly higher than those for IR-reference while C max and AUC were lower demonstrating the sustained release properties of the new formulation. In Study B comparing SR-test with SR-reference the observed C max and AUC of propafenone for SR-test (124.5±140.0 ng/mL and 612.0±699.2 ng·h/mL, respectively) were higher than for SR-reference (78.52±72.92 ng/mL and 423.6±431.6 ng·h/mL, respectively) although the differences were not significant. Overall, the new formulation has as good if not better sustained release characteristics to the market leader formulation.

  3. Thoracolumbar imbalance analysis for osteotomy planification using a new method: FBI technique.

    PubMed

    Le Huec, J C; Leijssen, P; Duarte, M; Aunoble, S

    2011-09-01

    Treatment of spine imbalance by posterior osteotomy is a valuable technique. Several surgical techniques have been developed and proposed to redress the vertebral column in harmonious kyphosis in order to recreate correct sagittal alignment. Although surgical techniques proved to be adequate, preoperative planning still is mediocre. Multiple suggestions have been proposed, from cutting tracing paper to ingenious mathematical formulas and computerised models. The analysis of the pelvic parameters to try to recover the initial shape of the spine before the spine imbalance occurred is very important to avoid mistakes during the osteotomy planification. The authors proposed their method for the osteotomy planning paying attention to the pelvic, and spine parameters and in accordance with Roussouly's classification. The pre operative planning is based on a full-body X-ray including the spine from C1 to the femoral head and the first 10 cm of the femur shaft. Using all the balance parameters provided, a formula name FBI is proposed. Calculation of the osteotomy is basic goniometry, the midpoint of the C7 inferior plateau (point a) is transposed horizontally on the projected future C7 plumb line (point b) crossing posterior S1 plateau on a sagittal X-ray. These are the first two reference points. A third reference point is made on the anterior wall of the selected vertebra for osteotomy at mid height of the pedicle (point c) mainly L4 vertebra. These three points form a triangle with the tip being the third reference point. The angle represented by this triangle is the theoretical angle of the osteotomy. Two more angles should be measured and eventually added. The femur angulation measured as the inclination of the femoral axis to the vertical. And a third angle named the compensatory pelvic tilt to integrate the type of pelvis. If the pelvic tilt is between 15 and 25° or is higher than 25° you must add 5 or 10°, respectively. This compensatory tilt is based on a clinical analysis of operated patients. This planification was applied in a retrospective study of 18 patients and showed why in some cases improper correction was performed and prospectively in 8 cases with good clinical outcomes and correct spinal alignment. Sometimes it is necessary to find an acceptable compromise when rebalancing the spine paying attention to the general parameters of the patients like: age, osteoporosis, systemic disease etc. This FBI technique can be used even for small lordosis restoration: it gave a good evaluation of the amount of correction needed and then the surgeon had the choice to use the appropriate technique to obtain a good balance.

  4. Aquarius L-Band Radiometers Calibration Using Cold Sky Observations

    NASA Technical Reports Server (NTRS)

    Dinnat, Emmanuel P.; Le Vine, David M.; Piepmeier, Jeffrey R.; Brown, Shannon T.; Hong, Liang

    2015-01-01

    An important element in the calibration plan for the Aquarius radiometers is to look at the cold sky. This involves rotating the satellite 180 degrees from its nominal Earth viewing configuration to point the main beams at the celestial sky. At L-band, the cold sky provides a stable, well-characterized scene to be used as a calibration reference. This paper describes the cold sky calibration for Aquarius and how it is used as part of the absolute calibration. Cold sky observations helped establish the radiometer bias, by correcting for an error in the spillover lobe of the antenna pattern, and monitor the long-term radiometer drift.

  5. Stress Analysis of Pallet Lever Shaft

    DTIC Science & Technology

    1976-03-01

    ductile, plastic failure. 34 ^Ki’ ■^ ’- l^f. REFERENCES 1. L. Farace , "Runaway Escapement Redesign M125A1 Modular Booster", Tech... Farace 1 Attn: MDC 1 Attn: MDC-A, Mr. F. Shinaly 1 Attn: MDM 1 Attn: MDS 1 Attn: MDS-S 1 Attn: FI 1 Attn: MT Frankford Arsenal (Cont) 1

  6. Renorming c0 and closed, bounded, convex sets with fixed point property for affine nonexpansive mappings

    NASA Astrophysics Data System (ADS)

    Nezir, Veysel; Mustafa, Nizami

    2017-04-01

    In 2008, P.K. Lin provided the first example of a nonreflexive space that can be renormed to have fixed point property for nonexpansive mappings. This space was the Banach space of absolutely summable sequences l1 and researchers aim to generalize this to c0, Banach space of null sequences. Before P.K. Lin's intriguing result, in 1979, Goebel and Kuczumow showed that there is a large class of non-weak* compact closed, bounded, convex subsets of l1 with fixed point property for nonexpansive mappings. Then, P.K. Lin inspired by Goebel and Kuczumow's ideas to give his result. Similarly to P.K. Lin's study, Hernández-Linares worked on L1 and in his Ph.D. thesis, supervisored under Maria Japón, showed that L1 can be renormed to have fixed point property for affine nonexpansive mappings. Then, related questions for c0 have been considered by researchers. Recently, Nezir constructed several equivalent norms on c0 and showed that there are non-weakly compact closed, bounded, convex subsets of c0 with fixed point property for affine nonexpansive mappings. In this study, we construct a family of equivalent norms containing those developed by Nezir as well and show that there exists a large class of non-weakly compact closed, bounded, convex subsets of c0 with fixed point property for affine nonexpansive mappings.

  7. 46 CFR 160.047-1 - Incorporation by reference.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... reference to the following documents: (1) Federal Specification: L-P-375C—Plastic Film, Flexible, Vinyl... part of this subpart: Dwg. No. 160.047-1: Sheet 1, Rev. 2—Cutting Pattern and General Arrangement, Models AK-1, and AF-1. Sheet 2, Rev. 2—Cutting Pattern and General Arrangement, Models CKM-1 and CFM-1...

  8. 46 CFR 160.047-1 - Incorporation by reference.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... reference to the following documents: (1) Federal Specification: L-P-375C—Plastic Film, Flexible, Vinyl... part of this subpart: Dwg. No. 160.047-1: Sheet 1, Rev. 2—Cutting Pattern and General Arrangement, Models AK-1, and AF-1. Sheet 2, Rev. 2—Cutting Pattern and General Arrangement, Models CKM-1 and CFM-1...

  9. 46 CFR 160.047-1 - Incorporation by reference.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... reference to the following documents: (1) Federal Specification: L-P-375C—Plastic Film, Flexible, Vinyl... part of this subpart: Dwg. No. 160.047-1: Sheet 1, Rev. 2—Cutting Pattern and General Arrangement, Models AK-1, and AF-1. Sheet 2, Rev. 2—Cutting Pattern and General Arrangement, Models CKM-1 and CFM-1...

  10. 46 CFR 160.047-1 - Incorporation by reference.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... reference to the following documents: (1) Federal Specification: L-P-375C—Plastic Film, Flexible, Vinyl... part of this subpart: Dwg. No. 160.047-1: Sheet 1, Rev. 2—Cutting Pattern and General Arrangement, Models AK-1, and AF-1. Sheet 2, Rev. 2—Cutting Pattern and General Arrangement, Models CKM-1 and CFM-1...

  11. Port Needs Study (Vessel Traffic Services Benefits). Volume 2: Appendices, Part 1

    DTIC Science & Technology

    1991-08-01

    34 (Reference 1) and with its companion , Point Arguello, has been the graveyard of many ships. The Point Conception area has been described as a transition...North entrance to the Inner Harbor Navigation Canal, and that portion of the ICW Rigolets-New Orleans Cut west of a point one mile east of Chef

  12. Radiation resistance of lactobacilli isolated from radurized meat relative to growth and environment.

    PubMed

    Hastings, J W; Holzapfel, W H; Niemand, J G

    1986-10-01

    Of 113 lactobacilli isolated from radurized (5 kGy) minced meat, 7 Lactobacillus sake strains, 1 L. curvatus strain, and 1 L. farciminis strain were used for radiation resistance studies in a semisynthetic substrate (i.e., modified MRS broth). Five reference Lactobacillus spp., one Staphylococcus aureus strain, and one Salmonella typhimurium strain were used for comparative purposes. All L. sake isolates exhibited the phenomenon of being more resistant to gamma-irradiation in the exponential (log) phase than in the stationary phase of their growth cycles by a factor of 28%. Four references strains also exhibited this phenomenon, with L. sake (DSM 20017) showing a 68% increase in resistance in the log phase over the stationary phase. This phenomenon was not common to all bacteria tested and is not common to all strains with high radiation resistance. Four L. sake isolates and three reference strains were used in radiation sensitivity testing in a natural food system (i.e., meat). The bacteria were irradiated in minced meat and packaged under four different conditions (air, vacuum, CO2, and N2). Organisms exhibited the highest death rate (lowest D10 values [doses required to reduce the logarithm of the bacterial population by 1] ) under CO2 packaging conditions, but resistance to irradiation was increased under N2. The D10 values of the isolates were generally greater than those of the reference strains. The D10 values were also higher (approximately two times) in meat than in semisynthetic growth medium.

  13. Radiation resistance of lactobacilli isolated from radurized meat relative to growth and environment.

    PubMed Central

    Hastings, J W; Holzapfel, W H; Niemand, J G

    1986-01-01

    Of 113 lactobacilli isolated from radurized (5 kGy) minced meat, 7 Lactobacillus sake strains, 1 L. curvatus strain, and 1 L. farciminis strain were used for radiation resistance studies in a semisynthetic substrate (i.e., modified MRS broth). Five reference Lactobacillus spp., one Staphylococcus aureus strain, and one Salmonella typhimurium strain were used for comparative purposes. All L. sake isolates exhibited the phenomenon of being more resistant to gamma-irradiation in the exponential (log) phase than in the stationary phase of their growth cycles by a factor of 28%. Four references strains also exhibited this phenomenon, with L. sake (DSM 20017) showing a 68% increase in resistance in the log phase over the stationary phase. This phenomenon was not common to all bacteria tested and is not common to all strains with high radiation resistance. Four L. sake isolates and three reference strains were used in radiation sensitivity testing in a natural food system (i.e., meat). The bacteria were irradiated in minced meat and packaged under four different conditions (air, vacuum, CO2, and N2). Organisms exhibited the highest death rate (lowest D10 values [doses required to reduce the logarithm of the bacterial population by 1] ) under CO2 packaging conditions, but resistance to irradiation was increased under N2. The D10 values of the isolates were generally greater than those of the reference strains. The D10 values were also higher (approximately two times) in meat than in semisynthetic growth medium. PMID:3096207

  14. Pharmacokinetics and Bioequivalence of Two Formulations of Febuxostat 40-Mg and 80-Mg Tablets: A Randomized, Open-Label, 4-Way Crossover Study in Healthy Chinese Male Volunteers.

    PubMed

    Luo, Zhu; Nan, Feng; Miao, Jia; Chen, Zhihui; Li, Mei; Liang, Maozhi

    2016-01-01

    The present study aimed to investigate the pharmacokinetic properties of febuxostat in healthy Chinese male volunteers and evaluate whether the two formulations of febuxostat 40-mg and 80-mg tablets are bioequivalent. A randomized, open-label, 4-way crossover study was conducted in healthy Chinese male volunteers under fasting conditions. 24 eligible subjects were randomized in a 1:1:1:1 ratio to receive a single dose of test or reference formulation of febuxostat 40-mg or 80-mg tablet. The washout period between each administration was 1 week. Plasma febuxostat was quantified by a validated liquid chromatography-tandem mass spectrometry (LC-MS/MS) method. Tolerability was evaluated by monitoring adverse events, physical examinations, 12-lead ECG and laboratory tests. After single-dosing of 1 tablet of 40-mg febuxostat, the pharmacokinetic parameters of test and reference formulations were: Tmax 1.22±0.87 and 1.85±1.03 h, Cmax 1689.16±461.31 and 1613.80±608.43 ng·mL-1, AUC0-t 5139.87±1349.28 and 5517.91±2024.26 ng·mL-1·h, AUC0-∞ 5263.06±1339.16 and 5640.48±2040.22 ng·mL-1·h, t1/2 4.82±2.61 and 4.85±1.78 h, respectively. After single-dosing of 1 tablet of 80-mg febuxostat, the pharmacokinetic parameters of test and reference formulations were: Tmax 1.71±1.21 and 2.23±1.55 h, Cmax 2744.47±1157.44 and 2998.17±1200.13 ng·mL-1, AUC0-t 9634.03±2768.25 and 10467.95±3501.65 ng·mL-1·h, AUC0-∞ 9834.32±2730.51 and 10626.63±3504.08 ng·mL-1·h, t1/2 6.25±2.44 and 5.46±1.65 h, respectively. For single-dosing of 1 tablet of 40-mg febuxostat, 90% CIs for the test/reference ratio of AUC0-t, AUC0-∞ and Cmax were 89.79 to 102.55, 90.14 to 102.56 and 93.99 to 129.63, respectively. For single-dosing of 1 tablet of 80-mg febuxostat, 90% CIs for the test/reference ratio of AUC0-t, AUC0-∞ and Cmax were 86.67 to 100.00, 87.50 to 100.51 and 79.48 to 105.99, respectively. This single dose study revealed similar pharmacokinetic properties in healthy Chinese male volunteers as those found in Caucasic population. The test and reference febuxostat tablets formulations met the regulatory criteria for bioequivalence at 40-mg and 80-mg strengths in fasting healthy Chinese male volunteers. Chictr.org ChiCTR-TTRCC-14004288.

  15. Plasma Biomarkers Reflecting Profibrotic Processes in Heart Failure With a Preserved Ejection Fraction

    PubMed Central

    Zile, Michael R.; Jhund, Pardeep S.; Baicu, Catalin F.; Claggett, Brian L.; Pieske, Burkert; Voors, Adriaan A.; Prescott, Margaret F.; Shi, Victor; Lefkowitz, Martin; McMurray, John J.V.; Solomon, Scott D.

    2017-01-01

    Background Heart failure with preserved ejection fraction is a clinical syndrome that has been associated with changes in the extracellular matrix. The purpose of this study was to determine whether profibrotic biomarkers accurately reflect the presence and severity of disease and underlying pathophysiology and modify response to therapy in patients with heart failure with preserved ejection fraction. Methods and Results Four biomarkers, soluble form of ST2 (an interleukin-1 receptor family member), galectin-3, matrix metalloproteinase-2, and collagen III N-terminal propeptide were measured in the Prospective Comparison of ARNI With ARB on Management of Heart Failure With Preserved Ejection Fraction (PARAMOUNT) trial at baseline, 12 and 36 weeks after randomization to valsartan or LCZ696. We examined the relationship between baseline biomarkers, demographic and echocardiographic characteristics, change in primary (change in N-terminal pro B-type natriuretic peptide) and secondary (change in left atrial volume) end points. The median (interquartile range) value for soluble form of ST2 (33 [24.6–48.1] ng/mL) and galectin 3 (17.8 [14.1–22.8] ng/mL) were higher, and for matrix metalloproteinase-2 (188 [155.5–230.6] ng/mL) lower, than in previously published referent controls; collagen III N-terminal propeptide (5.6 [4.3–6.9] ng/mL) was similar to referent control values. All 4 biomarkers correlated with severity of disease as indicated by N-terminal pro B-type natriuretic peptide, E/E′, and left atrial volume. Baseline biomarkers did not modify the response to LCZ696 for lowering N-terminal pro B-type natriuretic peptide; however, left atrial volume reduction varied by baseline level of soluble form of ST2 and galectin 3; patients with values less than the observed median (<33 ng/mL soluble form of ST2 and <17.8 ng/mL galectin 3) had reduction in left atrial volume, those above median did not. Although LCZ696 reduced N-terminal pro B-type natriuretic peptide, levels of the other 4 biomarkers were not affected over time. Conclusions In patients with heart failure with preserved ejection fraction, biomarkers that reflect collagen homeostasis correlated with the presence and severity of disease and underlying pathophysiology, and may modify the structural response to treatment. PMID:26754625

  16. Heterologous expression of C. elegans fat-1 decreases the n-6/n-3 fatty acid ratio and inhibits adipogenesis in 3T3-L1 cells

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    An, Lei, E-mail: anleim@yahoo.com.cn; Pang, Yun-Wei, E-mail: yunweipang@126.com; Gao, Hong-Mei, E-mail: Gaohongmei_123@yahoo.cn

    Highlights: Black-Right-Pointing-Pointer Expression of C. elegans fat-1 reduces the n-6/n-3 PUFA ratio in 3T3-L1 cells. Black-Right-Pointing-Pointer fat-1 inhibits the proliferation and differentiation of 3T3-L1 preadipocytes. Black-Right-Pointing-Pointer fat-1 reduces lipid deposition in 3T3-L1 adipocytes. Black-Right-Pointing-Pointer The lower n-6/n-3 ratio induces apoptosis in 3T3-L1 adipocytes. -- Abstract: In general, a diet enriched in polyunsaturated fatty acids (PUFAs) inhibits the development of obesity and decreases adipose tissue. The specific impacts of n-3 and n-6 PUFAs on adipogenesis, however, have not been definitively determined. Traditional in vivo and in vitro supplementation studies have yielded inconsistent or even contradictory results, which likely reflect insufficiently controlledmore » experimental systems. Caenorhabditiselegans fat-1 gene encodes an n-3 fatty acid desaturase, and its heterologous expression represents an effective method both for altering the n-6/n-3 PUFA ratio and for evaluating the biological effects of n-3 and n-6 PUFAs. We sought to determine whether a reduced n-6/n-3 ratio could influence adipogenesis in 3T3-L1 cells. Lentivirus-mediated introduction of the fat-1 gene into 3T3-L1 preadipocytes significantly reduced the n-6/n-3 ratio and inhibited preadipocyte proliferation and differentiation. In mature adipocytes, fat-1 expression reduced lipid deposition, as measured by Oil Red O staining, and induced apoptosis. Our results indicate that a reduced n-6/n-3 ratio inhibits adipogenesis through several mechanisms and that n-3 PUFAs more effectively inhibit adipogenesis (but not lipogenesis) than do n-6 PUFAs.« less

  17. Accuracy of cystatin C for the detection of abnormal renal function in children undergoing chemotherapy for malignancy: a systematic review using individual patient data.

    PubMed

    Whiting, Penny; Birnie, Kate; Sterne, Jonathan A C; Jameson, Catherine; Skinner, Rod; Phillips, Bob

    2018-05-01

    We conducted a systematic review and individual patient data (IPD) meta-analysis to examine the utility of cystatin C for evaluation of glomerular function in children with cancer. Eligible studies evaluated the accuracy of cystatin C for detecting poor renal function in children undergoing chemotherapy. Study quality was assessed using QUADAS-2. Authors of four studies shared IPD. We calculated the correlation between log cystatin C and GFR stratified by study and measure of cystatin C. We dichotomized the reference standard at GFR 80 ml/min/1.73m 2 and stratified cystatin C at 1 mg/l, to calculate sensitivity and specificity in each study and according to age group (0-4, 5-12, and ≥ 13 years). In sensitivity analyses, we investigated different GFR and cystatin C cut points. We used logistic regression to estimate the association of impaired renal function with log cystatin C and quantified diagnostic accuracy using the area under the ROC curve (AUC). Six studies, which used different test and reference standard thresholds, suggested that cystatin C has the potential to monitor renal function in children undergoing chemotherapy for malignancy. IPD data (504 samples, 209 children) showed that cystatin C has poor sensitivity (63%) and moderate specificity (89%), although use of a GFR cut point of < 60 ml/min/1.73m 2 (data only available from two of the studies) estimated sensitivity to be 92% and specificity 81.3%. The AUC for the combined data set was 0.890 (95% CI 0.826, 0.951). Diagnostic accuracy appeared to decrease with age. Cystatin C has better diagnostic accuracy than creatinine as a test for glomerular dysfunction in young people undergoing treatment for cancer. Diagnostic accuracy is not sufficient for it to replace current reference standards for predicting clinically relevant impairments that may alter dosing of important nephrotoxic agents.

  18. Barbers Point Harbor, Hawaii, Jetty Modification Study

    DTIC Science & Technology

    2008-11-01

    jetty lengths do not adversely impact the wave environment in the vicinity of the jetty. Production phase Figure 18 shows the normalized incident...objective of these current measurements is to show that the proposed jetty will not have any adverse impacts on the existing current patterns with no...with minimal construction costs and impact on the environment. ERDC/CHL TR-08-16 83 References Briggs, M. J., L. S. Lillycrop, G. S. Harkins

  19. Comparing age-wise reference intervals for serum creatinine concentration in a "Reality check" of the recommended cut-off.

    PubMed

    Verma, Mascha; Khadapkar, Rashmi; Sahu, Priyadarshi Soumyaranjan; Das, Bibhu Ranjan

    2006-09-01

    An increase in the communication within the healthcare services, both nationally and internationally, has strengthened the need for harmonization of measurements and reference intervals in laboratory medicine. In the present report, the calculated reference interval for serum creatinine (sCr) levels of healthy normal individuals (n=1121) in different sex and age groups are compared with the established interval. The calculated reference interval for sCr level was 0.4-1.3 mg/dL and 0.6 to 1.3 mg/dL in the age groups of 21-40 and 41-60 years respectively. The difference between the mean sCr values in total males and total females (age range 21-60 years) was statistically significant (p<0.0001); When male and female subjects were analyzed age-group wise, the data showed a significant difference in mean sCr values (p<0.0001) in three age groups (21-30, 31-40 and 41-50 years) however, in older age group (51-60 years), the difference was non-significant (p=0.07). The reference ranges were 0.7-1.3 and 0.4-1.0 mg/dL for males and females respectively where the lower limit was 0.1-0.2 units less than that of standard limits. An increase in the mean value of sCr was observed particularly in females with an increase in age. Hence it is of interest to validate an age specific reference ranges for sCr in our population.

  20. Factors influencing the decline in lung density in a Danish lung cancer screening cohort.

    PubMed

    Shaker, Saher B; Dirksen, Asger; Lo, Pechin; Skovgaard, Lene T; de Bruijne, Marleen; Pedersen, Jesper H

    2012-11-01

    Lung cancer screening trials provide an opportunity to study the natural history of emphysema by using computed tomography (CT) lung density as a surrogate parameter. In the Danish Lung Cancer Screening Trial, 2,052 participants were included. At screening rounds, smoking habits were recorded and spirometry was performed. CT lung density was measured as the volume-adjusted 15th percentile density (PD15). A mixed effects model was used with former smoking males with <30 pack-yrs and without airflow obstruction (AFO) at entry as a reference group. At study entry, 893 (44%) participants had AFO. For the reference group, PD15 was 72.6 g·L(-1) with an annual decline of -0.33 g·L(-1). Female sex and current smoking increased PD15 at baseline, 17.3 g·L(-1) (p<0.001) and 10 g·L(-1) (p<0.001), respectively; and both increased the annual decline in PD15 (female: -0.3 g·L(-1); current smoking: -0.4 g·L(-1)). The presence and severity of AFO was a strong predictor of low PD15 at baseline (Global Initiative for Chronic Obstructive Lung Disease (GOLD) I: -1.4 g·L(-1); GOLD II: -6.3 g·L(-1); GOLD III: -17 g·L(-1)) and of increased annual decline in PD15 (GOLD I: -0.2 g·L(-1); GOLD II: -0.5 g·L(-1); GOLD III: -0.5 g·L(-1)). Female sex, active smoking and the presence of AFO are associated with accelerated decline in lung density.

  1. Representation of magnetic fields in space. [special attention to Geomagnetic fields and Magnetospheric models

    NASA Technical Reports Server (NTRS)

    Stern, D. P.

    1976-01-01

    Several mathematical methods which are available for the description of magnetic fields in space are reviewed. Examples of the application of such methods are given, with particular emphasis on work related to the geomagnetic field, and their individual properties and associated problems are described. The methods are grouped in five main classes: (1) methods based on the current density, (2) methods using the scalar magnetic potential, (3) toroidal and poloidal components of the field and spherical vector harmonics, (4) Euler potentials, and (5) local expansions of the field near a given reference point. Special attention is devoted to models of the magnetosphere, to the uniqueness of the scalar potential as derived from observed data, and to the L parameter.

  2. VizieR Online Data Catalog: SG1120-1202 members HST imaging & 24um fluxes (Monroe+, 2017)

    NASA Astrophysics Data System (ADS)

    Monroe, J. T.; Tran, K.-V. H.; Gonzalez, A. H.

    2017-09-01

    We employ HST imaging of an ~8'x12' mosaic across three filters: F390W (WFC3/UVIS), F606W (ACS/WFC), and F814W (ACS/WFC) for a total of 44 pointings (combined primary and parallels) during cycles 14 (GO 10499) and 19 (GO 12470). We use the Spitzer MIPS 24um fluxes from Saintonge+ (2008ApJ...685L.113S) and Tran+ (2009ApJ...705..809T). The 24um observations were retrieved from the Spitzer archive. For details on spectroscopy from multi-band ground-based observations using Magellan (in 2006), MMT, and VLT/VIMOS (in 2003), we refer the reader to Tran+ (2009ApJ...705..809T). (1 data file).

  3. Female and Male Size, Strength and Performance: A Review of Current Literature

    DTIC Science & Technology

    1981-11-01

    8217- Study: Fortney, Suzanne M. and L.C. Senay Jr. Effect of Training and Heat Acclimation on Exercise Responses of Sedentary Females. J. Appl. Physiol...Sohar Age and Sex Difference in Response to Short Exposure to Extreme Dry Heat. J. A lied Physiol.: Respirat. Environ. Exercise Physiol. 4(1): I-4, 1978...environmental heat stress. Ci ted References: 24 references :*1 -137- Study: Wells, Christine L. and Steven M. Horvath Responses to Exercise in a Hot

  4. Saxagliptin and cardiovascular outcomes in patients with type 2 diabetes and moderate or severe renal impairment: observations from the SAVOR-TIMI 53 Trial.

    PubMed

    Udell, Jacob A; Bhatt, Deepak L; Braunwald, Eugene; Cavender, Matthew A; Mosenzon, Ofri; Steg, Ph Gabriel; Davidson, Jaime A; Nicolau, Jose C; Corbalan, Ramon; Hirshberg, Boaz; Frederich, Robert; Im, KyungAh; Umez-Eronini, Amarachi A; He, Ping; McGuire, Darren K; Leiter, Lawrence A; Raz, Itamar; Scirica, Benjamin M

    2015-04-01

    The glycemic management of patients with type 2 diabetes mellitus (T2DM) and renal impairment is challenging, with few treatment options. We investigated the effect of saxagliptin in the Saxagliptin Assessment of Vascular Outcomes Recorded in Patients with Diabetes Mellitus (SAVOR)-Thrombolysis in Myocardial Infarction (TIMI) 53 trial according to baseline renal function. Patients with T2DM at risk for cardiovascular events were stratified as having normal or mildly impaired renal function (estimated glomerular filtration rate [eGFR] >50 mL/min/1.73 m(2); n = 13,916), moderate renal impairment (eGFR 30-50 mL/min/1.73 m(2); n = 2,240), or severe renal impairment (eGFR <30 mL/min/1.73 m(2); n = 336) and randomized to receive saxagliptin or placebo. The primary end point was cardiovascular death, myocardial infarction, or ischemic stroke. After a median duration of 2 years, saxagliptin neither increased nor decreased the risk of the primary and secondary composite end points compared with placebo, irrespective of renal function (all P for interactions ≥ 0.19). Overall, the risk of hospitalization for heart failure among the three eGFR groups of patients was 2.2% (referent), 7.4% (adjusted hazard ratio [HR] 2.38 [95% CI 1.95-2.91], P < 0.001), and 13.0% (adjusted HR 4.59 [95% CI 3.28-6.28], P < 0.001), respectively. The relative risk of hospitalization for heart failure with saxagliptin was similar (P for interaction = 0.43) in patients with eGFR >50 mL/min/1.73 m(2) (HR 1.23 [95% CI 0.99-1.55]), eGFR 30-50 mL/min/1.73 m(2) (HR 1.46 [95% CI 1.07-2.00]), and in patients with eGFR <30 (HR 0.94 [95% CI 0.52-1.71]). Patients with renal impairment achieved reductions in microalbuminuria with saxagliptin (P = 0.041) that were similar to those of the overall trial population. Saxagliptin did not affect the risk of ischemic cardiovascular events, increased the risk of heart failure hospitalization, and reduced progressive albuminuria, irrespective of baseline renal function. © 2015 by the American Diabetes Association. Readers may use this article as long as the work is properly cited, the use is educational and not for profit, and the work is not altered.

  5. Exploring the reference point in prospect theory: gambles for length of life.

    PubMed

    van Osch, Sylvie M C; van den Hout, Wilbert B; Stiggelbout, Anne M

    2006-01-01

    Attitude toward risk is an important factor determining patient preferences. Risk behavior has been shown to be strongly dependent on the perception of the outcome as either a gain or a loss. According to prospect theory, the reference point determines how an outcome is perceived. However, no theory on the location of the reference point exists, and for the health domain, there is no direct evidence for the location of the reference point. This article combines qualitative with quantitative data to provide evidence of the reference point in life-year certainty equivalent (CE) gambles and to explore the psychology behind the reference point. The authors argue that goals (aspirations) in life influence the reference point. While thinking aloud, 45 healthy respondents gave certainty equivalents for life-year CE gambles with long and short durations of survival. Contrary to suggestions from the literature, qualitative data argued that the offered certainty equivalent most frequently served as the reference point. Thus, respondents perceived life-year CE gambles as mixed. Framing of the question and goals set in life appeared to be important factors behind the psychology of the reference point. On the basis of the authors' quantitative and qualitative data, they argue that goals alter the perception of outcomes as described by prospect theory by influencing the reference point. This relationship is more apparent for the near future as opposed to the remote future, as goals are mostly set for the near future.

  6. Long Term Missions at the Sun-Earth Libration Point L1: ACE, SOHO, and WIND

    NASA Technical Reports Server (NTRS)

    Roberts, Craig E.

    2011-01-01

    Three heliophysics missions - the Solar Heliospheric Observatory (SOHO), the Advanced Composition Explorer (ACE), and the Global Geoscience WIND - have been orbiting the Sun-Earth interior libration point L1 continuously since 1996, 1997, and 2004, respectively. ACE and WIND (both NASA missions) and SOHO (an ESA-NASA joint mission) are all operated from the NASA Goddard Space Flight Center Flight Dynamics Facility. While ACE and SOHO have been dedicated libration point orbiters since their launches, WIND prior to 2004 flew a remarkable 10-year deep-space trajectory that featured 38 targeted lunar flybys. The L1 orbits and the mission histories of the three spacecraft are briefly reviewed, and the station-keeping techniques and orbit maneuver experience are discussed.

  7. Low-Latitude Solar Wind During the Fall 1998 SOHO-Ulysses Quadrature

    NASA Technical Reports Server (NTRS)

    Poletto, G.; Suess, S. T.; Biesecker, D. A.; Esser, R.; Gloeckler, G.; Ko, Y.-K.; Zurbuchen, T. H.

    2002-01-01

    Solar and Heliospheric Observatory (SOH0)-Ulysses quadratures occur when the SOHO-Sun-Ulysses-included angle is 90 deg. These offer the opportunity to directly compare properties of plasma parcels, observed by SOHO [Dorningo et al.] in the low corona, with properties of the same parcels measured, in due time, in situ, by Ulysses [ Wenzel et al]. We refer the reader to Suess et al. for an extended discussion of SOHO-Ulysses quadrature geometry. Here it suffices to recall that there are two quadratures per year, as SOHO makes its one-year revolution around the Sun. This, because SOHO is at the L1 Lagrangian point, in essentially the same place as the Earth, while Ulysses is in a near-polar -5-year solar orbit with a perihelion of 1.34 AU and aphelion of 5.4 AU.

  8. Should all acutely ill children in primary care be tested with point-of-care CRP: a cluster randomised trial.

    PubMed

    Verbakel, Jan Y; Lemiengre, Marieke B; De Burghgraeve, Tine; De Sutter, An; Aertgeerts, Bert; Shinkins, Bethany; Perera, Rafael; Mant, David; Van den Bruel, Ann; Buntinx, Frank

    2016-10-06

    Point-of-care blood C-reactive protein (CRP) testing has diagnostic value in helping clinicians rule out the possibility of serious infection. We investigated whether it should be offered to all acutely ill children in primary care or restricted to those identified as at risk on clinical assessment. Cluster randomised controlled trial involving acutely ill children presenting to 133 general practitioners (GPs) at 78 GP practices in Belgium. Practices were randomised to undertake point-of-care CRP testing in all children (1730 episodes) or restricted to children identified as at clinical risk (1417 episodes). Clinical risk was assessed by a validated clinical decision rule (presence of one of breathlessness, temperature ≥ 40 °C, diarrhoea and age 12-30 months, or clinician concern). The main trial outcome was hospital admission with serious infection within 5 days. No specific guidance was given to GPs on interpreting CRP levels but diagnostic performance is reported at 5, 20, 80 and 200 mg/L. Restricting CRP testing to those identified as at clinical risk substantially reduced the number of children tested by 79.9 % (95 % CI, 77.8-82.0 %). There was no significant difference between arms in the number of children with serious infection who were referred to hospital immediately (0.16 % vs. 0.14 %, P = 0.88). Only one child with a CRP < 5 mg/L had an illness requiring admission (a child with viral gastroenteritis admitted for rehydration). However, of the 80 children referred to hospital to rule out serious infection, 24 (30.7 %, 95 % CI, 19.6-45.6 %) had a CRP < 5 mg/L. CRP testing should be restricted to children at higher risk after clinical assessment. A CRP < 5 mg/L rules out serious infection and could be used by GPs to avoid unnecessary hospital referrals. ClinicalTrials.gov Identifier: NCT02024282 (registered on 14 th September 2012).

  9. [Evaluation of accuracy and influence factors of bedside blood glucose monitoring in critically ill patients].

    PubMed

    Feng, Tao; Cao, Xiang-yuan

    2012-08-01

    To evaluate the accuracy and influence factors of point-of-care testing (POCT) for glucose in critically ill patients. Two hundred and forty critically ill patients aged ≥18 years in department of critical care medicine were enrolled. According to blood glucose level (BGL) during glucose control, patients were divided into three groups: (1) hypoglycemia group, BGL<4.5 mmol/L, n=32; (2) euglycemia group, BGL 4.5-8.3 mmol/L, n=138; (3) hyperglycemia group, BGL>8.3 mmol/L, n=70. The blood samples from vein, artery and capillary of patients were collected synchronically and the blood glucose of POCT were determined with glucose oxidase (GOD) and glucose dehydrogenase (GDH) methods, respectively, compared with blood glucose reference values of laboratory [hexokinase method (HK method)]. The accuracy of POCT for glucose and influence factors were analyzed statistically by the logistic regression method. (1) The inaccurate rates of glucose values in blood samples from vein, artery and capillary in hypoglycemia group (GDH method: 25.00%, 40.62%, 40.62%; GOD method: 59.38%, 71.88%, 71.88%) were significantly higher than those in euglycemia group (GDH method: 2.90%, 9.42%, 7.97%; GOD method: 18.12%, 27.54%, 27.54%) and hyperglycemia group (GDH method: 1.43%, 8.57%, 4.28%; GOD method: 11.43%, 8.57%, 11.43%, all P<0.01). (2) The average levels of difference for the glucose reference value of laboratory and the glucose value measured by glucometer in hypoglycemia group were 0.41-0.69 mmol/L (GDH method) and 0.92-1.18 mmol/L (GOD method), in euglycemia 0.16-0.33 mmol/L and 0.77-0.90 mmol/L, in hyperglycemia group -0.06-0.18 mmol/L and 0.56-0.76 mmol/L, respectively. (3) The correlation coefficients between the laboratory and glucometer in hypoglycemia group were respectively 0.812-0.853 (GDH method) and 0.723-0.816 (GOD method). The correlation coefficients in euglycemia group were 0.862-0.890 and 0.768-0.857. They were elevated to 0.922-0.957 and 0.896-0.922 in hyperglycemia group (all P<0.01). (4)On the influence factors of accuracy in POCT for glucose, BGL, acute physiology and chronic health evaluation II (APACHEII) score and hematocrit level were into the logistic regression equation. The accuracy of POCT for glucose was markedly affected by the BGL, severity of patients and hematocrit level during glucose control. Under hypoglycemia, the agreement between laboratory and glucometer measurements was obviously fallen and it tended to overestimate the patient's real glucose value.

  10. 40 CFR 63.1332 - Emissions averaging provisions.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... other controls for a Group 1 storage vessel, batch process vent, aggregate batch vent stream, continuous... in control after November 15, 1990. (2) Group 1 emission points, identified in paragraph (c)(3) of... applicable reference control technology or standard and the emissions allowed for the Group 1 emission point...

  11. 40 CFR 63.503 - Emissions averaging provisions.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... used in conjunction with other controls for a Group 1 storage vessel, batch front-end process vent... will be allowed only for the increase in control after November 15, 1990. (2) Group 1 emission points... Group 1 emission points that are controlled to a level less stringent than the reference control...

  12. 40 CFR 63.503 - Emissions averaging provisions.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... used in conjunction with other controls for a Group 1 storage vessel, batch front-end process vent... will be allowed only for the increase in control after November 15, 1990. (2) Group 1 emission points... Group 1 emission points that are controlled to a level less stringent than the reference control...

  13. 40 CFR 63.1332 - Emissions averaging provisions.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... other controls for a Group 1 storage vessel, batch process vent, aggregate batch vent stream, continuous... in control after November 15, 1990. (2) Group 1 emission points, identified in paragraph (c)(3) of... reference control technology or standard and the emissions allowed for the Group 1 emission point. Said...

  14. 40 CFR 63.503 - Emissions averaging provisions.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... used in conjunction with other controls for a Group 1 storage vessel, batch front-end process vent... will be allowed only for the increase in control after November 15, 1990. (2) Group 1 emission points... Group 1 emission points that are controlled to a level less stringent than the reference control...

  15. 40 CFR 63.503 - Emissions averaging provisions.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... used in conjunction with other controls for a Group 1 storage vessel, batch front-end process vent... will be allowed only for the increase in control after November 15, 1990. (2) Group 1 emission points... Group 1 emission points that are controlled to a level less stringent than the reference control...

  16. 40 CFR 63.503 - Emissions averaging provisions.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... used in conjunction with other controls for a Group 1 storage vessel, batch front-end process vent... will be allowed only for the increase in control after November 15, 1990. (2) Group 1 emission points... Group 1 emission points that are controlled to a level less stringent than the reference control...

  17. Chemical system biology based molecular interactions to identify inhibitors against Q151M mutant of HIV-1 reverse transcriptase.

    PubMed

    Pandey, Rajan Kumar; Sharma, Drista; Ojha, Rupal; Bhatt, Tarun Kumar; Prajapati, Vijay Kumar

    2018-05-09

    The emergence of mutations leading to drug resistance is the main cause of therapeutic failure in the human HIV infection. Chemical system biology approach has drawn great attention to discover new antiretroviral hits with high efficacy and negligible toxicity, which can be used as a prerequisite for HIV drug resistance global action plan 2017-21. To discover potential hits, we docked 49 antiretroviral analogs (n = 6294) against HIV-1 reverse transcriptase Q151M mutant & its wild-type form and narrow downed their number in three sequential modes of docking using Schrödinger suite. Later on, 80 ligands having better docking score than reference ligands (tenofovir and lamivudine) were screened for ADME, toxicity prediction, and binding energy estimation. Simultaneously, the area under the curve (AUC) was estimated using receiver operating characteristics (ROC) curve analysis to validate docking protocols. Finally, single point energy and molecular dynamics simulation approaches were performed for best two ligands (L3 and L14). This study reveals the antiretroviral efficacy of obtained two best ligands and delivers the hits against HIV-1 reverse transcriptase Q151M mutant. Copyright © 2018 Elsevier B.V. All rights reserved.

  18. Basic Geometric Support of Systems for Earth Observation from Geostationary and Highly Elliptical Orbits

    NASA Astrophysics Data System (ADS)

    Gektin, Yu. M.; Egoshkin, N. A.; Eremeev, V. V.; Kuznecov, A. E.; Moskatinyev, I. V.; Smelyanskiy, M. B.

    2017-12-01

    A set of standardized models and algorithms for geometric normalization and georeferencing images from geostationary and highly elliptical Earth observation systems is considered. The algorithms can process information from modern scanning multispectral sensors with two-coordinate scanning and represent normalized images in optimal projection. Problems of the high-precision ground calibration of the imaging equipment using reference objects, as well as issues of the flight calibration and refinement of geometric models using the absolute and relative reference points, are considered. Practical testing of the models, algorithms, and technologies is performed in the calibration of sensors for spacecrafts of the Electro-L series and during the simulation of the Arktika prospective system.

  19. Superfund Record of Decision: National Starch & Chemical ...

    EPA Pesticide Factsheets

    ... wlwr'c: III = hazan' illtlt'x. lIu!w = 1:~;tim..II'd wor.!;t CiI!;e illl ... s. Shon-term Effectiveness refers to the tec.h1uQ1 and ... It ru~sd~~~ l~~~ .: G!""ar:ts C=eek. ...

  20. A Cross-Cultural Study of Reference Point Adaptation: Evidence from China, Korea, and the US

    ERIC Educational Resources Information Center

    Arkes, Hal R.; Hirshleifer, David; Jiang, Danling; Lim, Sonya S.

    2010-01-01

    We examined reference point adaptation following gains or losses in security trading using participants from China, Korea, and the US. In both questionnaire studies and trading experiments with real money incentives, reference point adaptation was larger for Asians than for Americans. Subjects in all countries adapted their reference points more…

  1. Drinking water treatment response following a Colorado wildfire.

    PubMed

    Hohner, Amanda K; Cawley, Kaelin; Oropeza, Jill; Summers, R Scott; Rosario-Ortiz, Fernando L

    2016-11-15

    Wildfires can greatly alter the vegetation, soils, and hydrologic processes of watersheds serving as drinking water supplies, which may negatively influence source water quality and treatment. To address wildfire impacts on treatment, a drinking water intake below a burned watershed and an upstream, unburned reference site were monitored following the High Park wildfire (2012) in the Cache la Poudre watershed of northern Colorado, USA. Turbidity, nutrients, dissolved organic matter (DOM) character, coagulation treatability, and disinfection byproduct formation were evaluated and compared to pre-fire data. Post-fire paired spatial differences between the treatment plant intake and reference site for turbidity, nitrogen, and phosphorus increased by an order of magnitude compared to pre-fire differences. Fluorescence index (FI) values were significantly higher at the intake compared to the reference site (Δ = 0.04), and higher than pre-fire years, suggesting the wildfire altered the DOM character of the river. Total trihalomethane (TTHM) and haloacetonitrile (HAN4) formation at the intake were 10.1 μg L -1 and 0.91 μg L -1 higher than the reference site. Post-fire water was amenable to conventional treatment at a 10 mg L -1 higher average alum dose than reference samples. The intake was also monitored following rainstorms. Post-rainstorm samples showed the maximum observed FI values (1.52), HAN4 (3.4 μg mg C -1 ) and chloropicrin formation yields (3.6 μg mg C -1 ), whereas TTHM and haloacetic acid yields were not elevated. Several post-rainstorm samples presented treatment challenges, and even at high alum doses (65 mg L -1 ), showed minimal dissolved organic carbon removal (<10%). The degraded water quality of the post-rainstorm samples is likely attributed to the combined effects of runoff from precipitation and greater erosion following wildfire. Wildfire impacts cannot be separated from rainfall effects due to the lack of post-rainstorm samples from the reference site. Results suggest for this study region, wildfire may have consequences for influent water quality, coagulant dosing, and DBP speciation. Copyright © 2016 Elsevier Ltd. All rights reserved.

  2. Evaluation of 1,3-benzoxathiol-2-one Derivatives as Potential Antifungal Agents.

    PubMed

    Terra, Luciana; de L Chazin, Eliza; de S Sanches, Paola; Saito, Max; de Souza, Marcus V N; Gomes, Claudia R B; Wardell, James L; Wardell, Solange M S V; Sathler, Plinio C; Silva, Gabriela C C; Lione, Viviane O; Kalil, Marcos; Joffily, Ana; Castro, Helena C; Vasconcelos, Thatyana R A

    2018-01-01

    Over the last few years, fungal infections have emerged as a worrisome global public health problem. Candidiasis is a disease caused by Candida species and has been a problem worldwide mainly for immunosuppressed patients. Lately, the resistant strains and side effects have been reported as important issues for treating Candidiasis, which have to be solved by identifying new drugs. The goal of this work was to synthesize a series of 1,3-benzoxathiol-2-one derivatives, XYbenzo[ d][1,3]oxathiol-2-ones, and evaluate their antifungal activity against five Candida species. In vitro antifungal screening test and minimum inhibitory concentration determination were performed according to CLSI protocols using ketoconazole as the reference drug. The cytotoxicity of the most active compounds was evaluated by hemolysis and MTT (Vero cells) assays. Compounds 2 (XY = 6-hydroxy-5-nitro, MIC = 4-32 µg/mL) and 7 (XY = 6-acetoxy-5-nitro, MIC =16-64 µg/mL) showed good results when compared with current antifungals in CLSI values (MIC = 0.04-250 µg/mL). These compounds exhibited a safer cytotoxicity as well as a lower hemolytic profile than ketoconazole. Overall, the in vitro results pointed to the potential of compounds 2 and 7 as new antifungal prototypes to be further explored. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  3. Comment on "Construction of regular black holes in general relativity"

    NASA Astrophysics Data System (ADS)

    Bronnikov, Kirill A.

    2017-12-01

    We claim that the paper by Zhong-Ying Fan and Xiaobao Wang on nonlinear electrodynamics coupled to general relativity [Phys. Rev. D 94,124027 (2016)], although correct in general, in some respects repeats previously obtained results without giving proper references. There is also an important point missing in this paper, which is necessary for understanding the physics of the system: in solutions with an electric charge, a regular center requires a non-Maxwell behavior of Lagrangian function L (f ) , (f =Fμ νFμ ν) at small f . Therefore, in all electric regular black hole solutions with a Reissner-Nordström asymptotic, the Lagrangian L (f ) is different in different parts of space, and the electromagnetic field behaves in a singular way at surfaces where L (f ) suffers branching.

  4. Changes in aspects of social functioning depend upon prior changes in neurodisability in people with acquired brain injury undergoing post-acute neurorehabilitation.

    PubMed

    Fortune, Dónal G; Walsh, R Stephen; Waldron, Brian; McGrath, Caroline; Harte, Maurice; Casey, Sarah; McClean, Brian

    2015-01-01

    Post-acute community-based rehabilitation is effective in reducing disability. However, while social participation and quality of life are valued as distal outcomes of neurorehabilitation, it is often not possible to observe improvements on these outcomes within the limited time-frames used in most investigations of rehabilitation. The aim of the current study was to examine differences in the sequence of attainments for people with acquired brain injury (ABI) undergoing longer term post-acute neurorehabilitation. Participants with ABI who were referred to comprehensive home and community-based neurorehabilitation were assessed at induction to service, at 6 months and again at 1.5 years while still in service on the Mayo-Portland Adaptability Index (MPAI-4), Community Integration Questionnaire, Hospital Anxiety and Depression Scale, and World Health Organisation Quality of Life measure. At 6 months post-induction to service, significant differences were evident in MPAI abilities, adjustment, and total neurodisability; and in anxiety and depression. By contrast, there was no significant effect at 6 months on more socially oriented features of experience namely quality of life (QoL), Community Integration and Participation. Eighteen month follow-up showed continuation of the significant positive effects with the addition of QoL-related to physical health, Psychological health, Social aspects of QoL and Participation at this later time point. Regression analyses demonstrated that change in QoL and Participation were dependent upon prior changes in aspects of neurodisability. Age, severity or type of brain injury did not significantly affect outcome. Results suggest that different constructs may respond to neurorehabilitation at different time points in a dose effect manner, and that change in social aspects of experience may be dependent upon the specific nature of prior neurorehabilitation attainments.

  5. Changes in aspects of social functioning depend upon prior changes in neurodisability in people with acquired brain injury undergoing post-acute neurorehabilitation

    PubMed Central

    Fortune, Dónal G.; Walsh, R. Stephen; Waldron, Brian; McGrath, Caroline; Harte, Maurice; Casey, Sarah; McClean, Brian

    2015-01-01

    Post-acute community-based rehabilitation is effective in reducing disability. However, while social participation and quality of life are valued as distal outcomes of neurorehabilitation, it is often not possible to observe improvements on these outcomes within the limited time-frames used in most investigations of rehabilitation. The aim of the current study was to examine differences in the sequence of attainments for people with acquired brain injury (ABI) undergoing longer term post-acute neurorehabilitation. Participants with ABI who were referred to comprehensive home and community-based neurorehabilitation were assessed at induction to service, at 6 months and again at 1.5 years while still in service on the Mayo-Portland Adaptability Index (MPAI-4), Community Integration Questionnaire, Hospital Anxiety and Depression Scale, and World Health Organisation Quality of Life measure. At 6 months post-induction to service, significant differences were evident in MPAI abilities, adjustment, and total neurodisability; and in anxiety and depression. By contrast, there was no significant effect at 6 months on more socially oriented features of experience namely quality of life (QoL), Community Integration and Participation. Eighteen month follow-up showed continuation of the significant positive effects with the addition of QoL-related to physical health, Psychological health, Social aspects of QoL and Participation at this later time point. Regression analyses demonstrated that change in QoL and Participation were dependent upon prior changes in aspects of neurodisability. Age, severity or type of brain injury did not significantly affect outcome. Results suggest that different constructs may respond to neurorehabilitation at different time points in a dose effect manner, and that change in social aspects of experience may be dependent upon the specific nature of prior neurorehabilitation attainments. PMID:26441744

  6. Precision Pointing Control System (PPCS) system design and analysis. [for gimbaled experiment platforms

    NASA Technical Reports Server (NTRS)

    Frew, A. M.; Eisenhut, D. F.; Farrenkopf, R. L.; Gates, R. F.; Iwens, R. P.; Kirby, D. K.; Mann, R. J.; Spencer, D. J.; Tsou, H. S.; Zaremba, J. G.

    1972-01-01

    The precision pointing control system (PPCS) is an integrated system for precision attitude determination and orientation of gimbaled experiment platforms. The PPCS concept configures the system to perform orientation of up to six independent gimbaled experiment platforms to design goal accuracy of 0.001 degrees, and to operate in conjunction with a three-axis stabilized earth-oriented spacecraft in orbits ranging from low altitude (200-2500 n.m., sun synchronous) to 24 hour geosynchronous, with a design goal life of 3 to 5 years. The system comprises two complementary functions: (1) attitude determination where the attitude of a defined set of body-fixed reference axes is determined relative to a known set of reference axes fixed in inertial space; and (2) pointing control where gimbal orientation is controlled, open-loop (without use of payload error/feedback) with respect to a defined set of body-fixed reference axes to produce pointing to a desired target.

  7. InstantLabs Listeria monocytogenes food safety kit. Performance tested method 051304.

    PubMed

    Sharma, Neil; Bambusch, Lauren; Le, Thu; Morey, Amit

    2014-01-01

    The InstantLabs Listeria monocytogenes Food Safety Kit was validated against the International Organization for Standardization (ISO) reference method 11290-1 for the detection of Listeria monocytogenes and other Listeria species. The matrixes (stainless steel, sealed concrete, ice cream, whole milk, cheddar cheese, raw shrimp, hot dogs, deli turkey, and lettuce) were inoculated with approximately 1 CFU/test portion of L. monocytogenes to generate fractional positives (5-15) in 20 inoculated samples. Enrichments were also fractionally inoculated with L. grayii for side-by-side testing of the Listeria Species Food Safety Kit. Stainless steel and sealed concrete samples were validated using 4 x 4" and 1 x 1 " test areas, respectively, and enriched in Buffered Listeria Enrichment Broth (BLEB) at 35 +/- 1degreesC for 22-28 h. All food samples were tested at 25 g and enriched in BLEB at 35 +/- 1 degreesC for 24-28 h. All samples were confirmed using the ISO reference method, regardless of initial screen result. The InstantLabs test method performed as well as or better than the reference method for the detection of L. monocytogenes on stainless steel and sealed concrete and in ice cream, whole milk, cheddar cheese, raw shrimp, hot dogs, deli turkey, and lettuce. Inclusivity and exclusivity testing revealed no false negatives and no false positives among the 50 L. monocytogenes serovars and 30 non-L. monocytogenes species examined. The method was shown to be robust when the enrichment times, volumes for DNA extraction, and heat block times were varied.

  8. Spectrophotometric determination of low levels arsenic species in beverages after ion-pairing vortex-assisted cloud-point extraction with acridine red.

    PubMed

    Altunay, Nail; Gürkan, Ramazan; Kır, Ufuk

    2016-01-01

    A new, low-cost, micellar-sensitive and selective spectrophotometric method was developed for the determination of inorganic arsenic (As) species in beverage samples. Vortex-assisted cloud-point extraction (VA-CPE) was used for the efficient pre-concentration of As(V) in the selected samples. The method is based on selective and sensitive ion-pairing of As(V) with acridine red (ARH(+)) in the presence of pyrogallol and sequential extraction into the micellar phase of Triton X-45 at pH 6.0. Under the optimised conditions, the calibration curve was highly linear in the range of 0.8-280 µg l(-1) for As(V). The limits of detection and quantification of the method were 0.25 and 0.83 µg l(-1), respectively. The method was successfully applied to the determination of trace As in the pre-treated and digested samples under microwave and ultrasonic power. As(V) and total As levels in the samples were spectrophotometrically determined after pre-concentration with VA-CPE at 494 nm before and after oxidation with acidic KMnO4. The As(III) levels were calculated from the difference between As(V) and total As levels. The accuracy of the method was demonstrated by analysis of two certified reference materials (CRMs) where the measured values for As were statistically within the 95% confidence limit for the certified values.

  9. Hippocampal place cell and inhibitory neuron activity in disrupted-in-schizophrenia-1 mutant mice: implications for working memory deficits

    PubMed Central

    Mesbah-Oskui, Lia; Georgiou, John; Roder, John C

    2015-01-01

    Background: Despite the prevalence of working memory deficits in schizophrenia, the neuronal mechanisms mediating these deficits are not fully understood. Importantly, deficits in spatial working memory are identified in numerous mouse models that exhibit schizophrenia-like endophenotypes. The hippocampus is one of the major brain regions that actively encodes spatial location, possessing pyramidal neurons, commonly referred to as ‘place cells’, that fire in a location-specific manner. This study tests the hypothesis that mice with a schizophrenia-like endophenotype exhibit impaired encoding of spatial location in the hippocampus. Aims: To characterize hippocampal place cell activity in mice that exhibit a schizophrenia-like endophenotype. Methods: We recorded CA1 place cell activity in six control mice and six mice that carry a point mutation in the disrupted-in-schizophrenia-1 gene (Disc1-L100P) and have previously been shown to exhibit deficits in spatial working memory. Results: The spatial specificity and stability of Disc1-L100P place cells were similar to wild-type place cells. Importantly, however, Disc1-L100P place cells exhibited a higher propensity to increase their firing rate in a single, large location of the environment, rather than multiple smaller locations, indicating a generalization in their spatial selectivity. Alterations in the signaling and numbers of CA1 putative inhibitory interneurons and decreased hippocampal theta (5–12 Hz) power were also identified in the Disc1-L100P mice. Conclusions: The generalized spatial selectivity of Disc1-L100P place cells suggests a simplification of the ensemble place codes that encode individual locations and subserve spatial working memory. Moreover, these results suggest that deficient working memory in schizophrenia results from an impaired ability to uniquely code the individual components of a memory sequence. PMID:27280123

  10. Analytical performance of three whole blood point-of-care lactate devices compared to plasma lactate comparison methods and a flow-injection mass spectrometry method.

    PubMed

    Tolan, Nicole V; Wockenfus, Amy M; Koch, Christopher D; Crews, Bridgit O; Dietzen, Dennis J; Karon, Brad S

    2017-03-01

    Point of care (POC) whole blood lactate testing may facilitate rapid detection of sepsis. We evaluated three POC methods against both plasma lactate comparison methods and a flow-injection mass spectrometric (MS) method. Nova StatStrip, Abbott i-STAT CG4+ and Radiometer ABL90 POC lactate methods were evaluated against the mean of Cobas Integra 400 and Vitros 350 plasma lactate. POC methods were also compared to a flow-injection mass spectrometric assay measuring lactate in ZnSO 4 -precipitated whole blood extracts. Intra- and inter-assay precision was determined using quality control material. Method comparison included specimens from normal donors at rest, after exertion, and after spiking with lactic acid. Intra- and inter-assay coefficient of variation was <5% for i-STAT and ABL90; but ranged from 3.1-8.2% on two StatStrip meters. Mean (±SD) bias between POC and plasma lactate ranged from -0.2±0.9 (i-STAT and ABL90) to -0.4±1.2 (StatStrip) mmol/L. At concentrations >6mmol/L, all POC methods showed proportional negative bias compared to plasma methods; but this bias was not observed when compared to the MS method. Despite proportional negative bias, all POC methods demonstrated acceptable concordance (94-100%) with plasma lactate within the reference interval (<2.3mmol/L) and >4mmol/L, commonly used clinical cut-offs for detection of sepsis. POC lactate methods demonstrate acceptable concordance with plasma lactate across commonly used clinical cut-offs for detection of sepsis. Due to systematic negative bias at higher lactate concentrations, POC and plasma lactate should not be used interchangeably to monitor patients with elevated lactate concentrations. Copyright © 2016 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  11. The reference intervals of thyroid stimulating hormone in healthy individuals with normal levels of serum free thyroxine and without sonographic pathologies.

    PubMed

    Kutluturk, Faruk; Yildirim, Beytullah; Ozturk, Banu; Ozyurt, Huseyin; Bekar, Ulku; Sahin, Semsettin; Akturk, Yeliz; Akbas, Ali; Cetin, Ilhan; Etikan, Ilker

    2014-01-01

    The aim of the present study was to investigate the reference intervals for thyroid stimulating hormone (TSH) in healthy individuals with normal levels of serum free thyroxine (fT4) and without sonographic pathologies, and determine the effects of age, gender, and residence on the TSH reference intervals. This research was a population-based study conducted in 70 regions. The random sampling method was used to select the 1095 subjects of the study among inhabitants aged 18 and above. Patients who had a previous history of thyroid disease and had been taking medication were excluded from the study as this may have affected their fT4 or TSH levels. In addition, subjects who had serum fT4 without a reference range and abnormal ultrasonography findings were also excluded. A total of 408 subjects were used for establishing the reference intervals for TSH. The data for TSH in the study group were not normally distributed according to the Kolmogorov-Smirnov index. The geometric mean was 1.62 mIU/L, the median was 1.40 mIU/L, and the 95% reference intervals were 0.38-4.22 mIU/L. The median TSH level was higher in females compared to males (p < 0.05). In the female subjects 2.5th percentile of TSH was lower and 97.5th percentile was higher than those of males. The reference intervals of TSH were of lower values in subjects over 50 years old (p < 0.001). Studies suggest that determination of the TSH reference intervals may differ due to environmental influences or due to age, gender, and race. It is suggested that the lower limit of normal TSH for the adult Turkish population would be 0.38 mIU/L and the upper limit similar to the traditional value of 4.2 mIU/L. If each clinician uses their population-specific reference interval for TSH, thyroid function abnormalities can be accurately estimated.

  12. La Peur de L'évaluation: Évaluation de L'enseignement ou du Sujet?

    NASA Astrophysics Data System (ADS)

    Kosmidou-Hardy, Chryssoula; Marmarinos, Jean

    2001-03-01

    This article addresses first of all the question why nowadays evaluation is so intensively promoted. It then goes on to analyse the reasons why there is currently a resistance to evaluation among teachers. It refers especially to the situation in Greece, where evaluation has been absent since 1981, whereas before that date it was applied in an oppressive manner, more resembling discipline and punishment than the personal development of the teachers. The authors refer particularly to the work of Michel Foucault but also to that of J. F. Lyotard. They point out that it is the teachers' fear of evaluation of their personal identity rather than their professional competence that lies behind the resistance to evaluation. Emphasis is placed on the necessity to support teachers in their personal and professional development. The use of action research, termed "critical active research" in Greek, is advocated as a basic strategy for the development of the teacher as well as of the curriculum and of society in general.

  13. Improved sample preparation for GC-MS-SIM analysis of ethyl carbamate in wine.

    PubMed

    Nóbrega, Ian C C; Pereira, Giuliano E; Silva, Marileide; Pereira, Elainy V S; Medeiros, Marcelo M; Telles, Danuza L; Albuquerque, Eden C; Oliveira, Juliane B; Lachenmeier, Dirk W

    2015-06-15

    An improved sample preparation procedure for analysis of carcinogenic ethyl carbamate (EC) in wine by GC-MS-SIM is proposed. Differences over AOAC reference procedure were: (1) use of EC-d5 as internal standard instead of less similar propyl carbamate; (2) extraction by diethyl ether instead of more toxic dichloromethane, and (3) concentration by vacuum automated parallel evaporation instead of more time and work consuming rotary evaporation. Mean recovery was 104.4%, intraday precision was 6.7% (3.4 μg L(-)(1)) and 1.7% (88.5 μg L(-)(1)), regression coefficient was 0.999 in the linear working range of 3-89 μg L(-)(1), and limits of detection and quantification were 0.4 and 1.2 μg L(-)(1). Applicability was demonstrated by analysis (in triplicate) of 5 wine samples. EC concentration ranged from 5.2 ± 0.2 to 29.4 ± 1.5 μg L(-)(1). The analytical method is selective, accurate, repeatable, linear, and has similar method performance as the reference method along with the several mentioned advantages. Copyright © 2015 Elsevier Ltd. All rights reserved.

  14. Influence of a chlor-alkali superfund site on mercury bioaccumulation in periphyton and low-trophic level fauna.

    PubMed

    Buckman, Kate L; Marvin-DiPasquale, Mark; Taylor, Vivien F; Chalmers, Ann; Broadley, Hannah J; Agee, Jennifer; Jackson, Brian P; Chen, Celia Y

    2015-07-01

    In Berlin, New Hampshire, USA, the Androscoggin River flows adjacent to a former chlor-alkali facility that is a US Environmental Protection Agency Superfund site and source of mercury (Hg) to the river. The present study was conducted to determine the fate and bioaccumulation of methylmercury (MeHg) to lower trophic-level taxa in the river. Surface sediment directly adjacent to the source showed significantly elevated MeHg (10-40× increase, mean ± standard deviation [SD]: 20.1 ± 24.8 ng g(-1) dry wt) and total mercury (THg; 10-30× increase, mean ± SD: 2045 ± 2669 ng g(-1) dry wt) compared with all other reaches, with sediment THg and MeHg from downstream reaches elevated (3-7× on average) relative to the reference (THg mean ± SD: 33.5 ± 9.33 ng g(-1) dry wt; MeHg mean ± SD: 0.52 ± 0.21 ng g(-1) dry wt). Water column THg concentrations adjacent to the point source for both particulate (0.23 ng L(-1)) and dissolved (0.76 ng L(-1)) fractions were 5-fold higher than at the reference sites, and 2-fold to 5-fold higher than downstream. Methylmercury production potential of periphyton material was highest (2-9 ng g(-1) d(-1) dry wt) adjacent to the Superfund site; other reaches were close to or below reporting limits (0. 1 ng g(-1) d(-1) dry wt). Total Hg and MeHg bioaccumulation in fauna was variable across sites and taxa, with no clear spatial patterns downstream of the contamination source. Crayfish, mayflies, and shiners showed a weak positive relationship with porewater MeHg concentration. © 2015 SETAC.

  15. [Development of the certified reference material of mercury in lyophilized human urine].

    PubMed

    Zhao, Wei; Zhang, Fu-gang; DU, Hui-fang; Pan, Ya-juan; Yan, Hui-fang

    2011-02-01

    To develop the certified reference material of mercury in lyophilized human urine. Human urine samples from normal level mercury districts were filtered, homogenized, dispensed, lyophilized and radio-sterilized. Homogeneity test, stability inspection and certification were conducted using a atom fluorescence spectrophotometric method. The physical and chemical stability of the certified reference material were assessed for 18 months. The certified values are based on analysis made by three independent laboratories. The certified values are as follows: low level was (35.6 ± 2.1) µg/L, high level was (50.5 ± 3.0) µg/L. The certified reference material of mercury in lyophilized human urine in this research reached the national certified reference material requirements and could be used for the quality control.

  16. Mothers and fathers of young Dutch adolescents with Down syndrome: Health related quality of life and family functioning.

    PubMed

    Marchal, Jan Pieter; Maurice-Stam, Heleen; van Trotsenburg, A S Paul; Grootenhuis, Martha A

    2016-12-01

    Like any child, children with Down syndrome (DS) affect the lives of their families. Most studies focus on the adaptation of parents and families of young children with DS, while relatively few studies include the perspective of fathers. To determine 1) whether mothers and fathers of 11 to 13-year-olds with DS differ from reference parents in health related quality of life (HRQoL) and family functioning, and 2) whether HRQoL in parents of children with DS changes over time, from when the child was 6-8 years old to when the child was 11-13 years old. 80 mothers and 44 fathers completed HRQoL and family functioning questionnaires. 58 parents (53 mothers) had completed the HRQoL-questionnaire in a previous study. Mothers differed from reference mothers in one HRQoL-domain (Sexuality), while fathers' HRQoL did not significantly differ from reference fathers. Both mothers and fathers scored in the (sub)clinical range more frequently than reference parents in Total family functioning, and in the domains Partner relation and Social network. Furthermore, fathers scored in the (sub)clinical range more frequently than reference parents in Responsiveness and Organization. HRQoL showed no significant change over time. Our findings indicate frequent family functioning problems but few HRQoL problems in parents and families of children with DS. In offering care, a family based approach with special attention for partner relation and social functioning is needed. Copyright © 2016 Elsevier Ltd. All rights reserved.

  17. An Ecological Paradox: The African Wild Dog (Lycaon Pictus) Is Not Attracted to Water Points When Water Is Scarce in Hwange National Park, Zimbabwe.

    PubMed

    Ndaimani, Henry; Tagwireyi, Paradzayi; Sebele, Lovelater; Madzikanda, Hillary

    2016-01-01

    In dry biomes, spatio-temporal variation in surface water resource stocks is pervasive, with unknown effects on the ranging behaviour of large predators. This study assessed the effect of spatial variation in surface water resources on the ranging behaviour of the African wild dog (Lycaon pictus). We analyzed data for 1992 (dry year with 20 water points) and 2000 (wet year with 30 water points) against presence-only data for five packs of L. pictus in a part of Hwange National Park and adjacent smallholder communal farming areas in western Zimbabwe. Modelling the potential habitat for L. pictus using Maxent with distance from water points (Dw) and Normalized Difference Vegetation Index (NDVI) as predictor variables was successful for 2000 (AUC = 0.793) but not successful for 1992 (AUC = 0.423), with L. pictus probability of occurrence near water points being more for year 2000 than for year 1992. The predicted L. pictus range was wider in 1992 (~13888.1 km2) than in 2000 (~958.4 km2) (Test of Proportions, χ2 = 124.52, df = 1, P = 0.00). Using the 2nd order Multitype Nearest Neighbour Distance Function (Gcross), we also observed significant attraction between L. pictus and water points within only ~1km radius for 1992 but up to ~8km radius for 2000. Our study reinforced the notion that surface water resources attract wild dogs in the savannahs but paradoxically less so when water resources are scarce. In particular, our study furthers current understanding of the effects of changing water availability regimes on the endangered L. pictus, providing evidence that the endangered predator's home range encroaches into potential ecological traps (i.e., smallholder communal farming areas) when water resources are scarce.

  18. Mildly elevated lactate levels are associated with microcirculatory flow abnormalities and increased mortality: a microSOAP post hoc analysis.

    PubMed

    Vellinga, Namkje A R; Boerma, E Christiaan; Koopmans, Matty; Donati, Abele; Dubin, Arnaldo; Shapiro, Nathan I; Pearse, Rupert M; van der Voort, Peter H J; Dondorp, Arjen M; Bafi, Tony; Fries, Michael; Akarsu-Ayazoglu, Tulin; Pranskunas, Andrius; Hollenberg, Steven; Balestra, Gianmarco; van Iterson, Mat; Sadaka, Farid; Minto, Gary; Aypar, Ulku; Hurtado, F Javier; Martinelli, Giampaolo; Payen, Didier; van Haren, Frank; Holley, Anthony; Gomez, Hernando; Mehta, Ravindra L; Rodriguez, Alejandro H; Ruiz, Carolina; Canales, Héctor S; Duranteau, Jacques; Spronk, Peter E; Jhanji, Shaman; Hubble, Sheena; Chierego, Marialuisa; Jung, Christian; Martin, Daniel; Sorbara, Carlo; Bakker, Jan; Ince, Can

    2017-10-18

    Mildly elevated lactate levels (i.e., 1-2 mmol/L) are increasingly recognized as a prognostic finding in critically ill patients. One of several possible underlying mechanisms, microcirculatory dysfunction, can be assessed at the bedside using sublingual direct in vivo microscopy. We aimed to evaluate the association between relative hyperlactatemia, microcirculatory flow, and outcome. This study was a predefined subanalysis of a multicenter international point prevalence study on microcirculatory flow abnormalities, the Microcirculatory Shock Occurrence in Acutely ill Patients (microSOAP). Microcirculatory flow abnormalities were assessed with sidestream dark-field imaging. Abnormal microcirculatory flow was defined as a microvascular flow index (MFI) < 2.6. MFI is a semiquantitative score ranging from 0 (no flow) to 3 (continuous flow). Associations between microcirculatory flow abnormalities, single-spot lactate measurements, and outcome were analyzed. In 338 of 501 patients, lactate levels were available. For this substudy, all 257 patients with lactate levels ≤ 2 mmol/L (median [IQR] 1.04 [0.80-1.40] mmol/L) were included. Crude ICU mortality increased with each lactate quartile. In a multivariable analysis, a lactate level > 1.5 mmol/L was independently associated with a MFI < 2.6 (OR 2.5, 95% CI 1.1-5.7, P = 0.027). In a heterogeneous ICU population, a single-spot mildly elevated lactate level (even within the reference range) was independently associated with increased mortality and microvascular flow abnormalities. In vivo microscopy of the microcirculation may be helpful in discriminating between flow- and non-flow-related causes of mildly elevated lactate levels. ClinicalTrials.gov, NCT01179243 . Registered on August 3, 2010.

  19. Reference values of cadmium, arsenic and manganese in blood and factors associated with exposure levels among adult population of Rio Branco, Acre, Brazil.

    PubMed

    Freire, Carmen; Koifman, Rosalina Jorge; Fujimoto, Denys; de Oliveira Souza, Vanessa Cristina; Barbosa, Fernando; Koifman, Sergio

    2015-06-01

    This study aimed to investigate the distribution and factors influencing blood levels of Cadmium (Cd), Arsenic (As), and Manganese (Mn), and to determine their reference values in a sample of blood donors residing in Rio Branco, capital city of Acre State, Brazil. Blood samples were collected from all blood donors attending the Central Hemotherapic Unit in Rio Branco between 2010 and 2011. Among these, 1183 donors (98.9%) answered to a questionnaire on sociodemographic and lifestyle factors. Blood metal concentrations were determined by atomic spectrometry. Association between Cd, As and Mn levels and donors' characteristics was examined by linear regression analysis. Reference values were estimated as the upper limit of the 95% confidence interval of the 95th percentile of metal levels. References values were 0.87 μg L(-1) for Cd, 9.87 μg L(-1) for As, and 29.32 μg L(-1) for Mn. Reference values of Cd and As in smokers were 2.66 and 10.86 μg L(-1), respectively. Factors contributing to increase Cd levels were smoking, ethnicity (non-white), and lower education, whereas drinking tea and non-bottled water were associated with lower Cd. Lower levels of As were associated with higher household income, living near industrial facilities, working in a glass factory, a compost plant or in metal mining activities. Risk factors for Mn exposure were not identified. In general, blood Cd concentrations were in the range of exposure levels reported for other people from the general population, whereas levels of As and Mn were higher than in other non-occupationally exposed populations elsewhere. Copyright © 2015 Elsevier Ltd. All rights reserved.

  20. A Catalog of Absorption in the Spectra of Quasi-stellar Objects: Erratum (Orig. paper in 77, 203, 47-B1 (1991))

    NASA Astrophysics Data System (ADS)

    Junkkarinen, V.; Hewitt, A.; Burbidge, G.

    1992-07-01

    In the paper entitled "A Catalog of Absorption in the Spectra of Quasi- stellar Objects" by V. Junkkarinen, A. Hewitt, & G. Burbidge (ApJS, 77,203(1991]) there is an error in Table l. Because of an error in the computer program used to generate the final version of Table 1, the J2000 coordinates for all the objects are incorrect. The error involves the printed values for the J2000 seconds of time in right ascension and the J2000 seconds of arc in declination. The following table gives corrected J2000 coordinates for all the objects in Table 1 of our paper. Table 1 should be consulted for the 1950 coordinates and to check for coordinates which are poorly known. The J2000 coordinate names in Table 1 are correct (except that a few may change as more accurate coordinates become available for those QSOs with poorly determined coordinates), and the B1950 coordinates and coordinate names are not affected by the programming error. Additional corrections: In Table 3, 1040+015 should be QNB1:49, not QNB1:22. Two references were omitted (the numbers appear in Table 1, but the references are not listed): 1720. Djorgovski, S., Strauss, M. A., Perley, R. A., Spinrad, H., and McCarthy, P. 1987, AJ, 93,1318. 2115. Turnshek, D. A., Wolfe, A. M., Lanzetta, K. M., Briggs, F. H., Cohen, R. D., Foltz, C. B., Smith, H. E., and Wilkes, B. J. 1989, ApJ, 344,567. We would like to thank Marion Schmitz (IPAC) for pointing out the missing references and QNB1:49.

  1. Decentralized Estimation and Vision-based Guidance of Fast Autonomous Systems with Guaranteed Performance in Uncertain Environments

    DTIC Science & Technology

    2013-04-22

    Following for Unmanned Aerial Vehicles Using L1 Adaptive Augmentation of Commercial Autopilots, Journal of Guidance, Control, and Dynamics, (3 2010): 0...Naira Hovakimyan. L1 Adaptive Controller for MIMO system with Unmatched Uncertainties using Modi?ed Piecewise Constant Adaptation Law, IEEE 51st...adaptive input nominal input with  Nominal input L1 ‐based control generator  This L1 adaptive control architecture uses data from the reference model

  2. Blow-up solutions for L 2 supercritical gKdV equations with exactly k blow-up points

    NASA Astrophysics Data System (ADS)

    Lan, Yang

    2017-08-01

    In this paper we consider the slightly L 2-supercritical gKdV equations \\partialt u+(uxx+u\\vert u\\vert p-1)_x=0 , with the nonlinearity 5 and 0<\\varepsilon\\ll 1 . In the previous work of the author, we know that there exists a stable self-similar blow-up dynamics for slightly L 2-supercritical gKdV equations. Such solutions can be viewed as solutions with a single blow-up point. In this paper we will prove the existence of solutions with multiple blow-up points, and give a description of the formation of the singularity near the blow-up time.

  3. Allometric scaling of lung volume and its consequences for marine turtle diving performance.

    PubMed

    Hochscheid, Sandra; McMahon, Clive R; Bradshaw, Corey J A; Maffucci, Fulvio; Bentivegna, Flegra; Hays, Graeme C

    2007-10-01

    Marine turtle lungs have multiple functions including respiration, oxygen storage and buoyancy regulation, so lung size is an important indicator of dive performance. We determined maximum lung volumes (V(L)) for 30 individuals from three species (Caretta caretta n=13; Eretmochelys imbricata n=12; Natator depressus n=5) across a range of body masses (M(b)): 0.9 to 46 kg. V(L) was 114 ml kg(-1) and increased with M(b) with a scaling factor of 0.92. Based on these values for V(L) we demonstrated that diving capacities (assessed via aerobic dive limits) of marine turtles were potentially over-estimated when the V(L)-body mass effect was not considered (by 10 to 20% for 5 to 25 kg turtles and by >20% for turtles > or =25 kg). While aerobic dive limits scale with an exponent of 0.6, an analysis of average dive durations in free-ranging chelonian marine turtles revealed that dive duration increases with a mass exponent of 0.51, although there was considerable scatter around the regression line. While this highlights the need to determine more parameters that affect the duration-body mass relationship, our results provide a reference point for calculating oxygen storage capacities and air volumes available for buoyancy control.

  4. Numerical study of the directed polymer in a 1 + 3 dimensional random medium

    NASA Astrophysics Data System (ADS)

    Monthus, C.; Garel, T.

    2006-09-01

    The directed polymer in a 1+3 dimensional random medium is known to present a disorder-induced phase transition. For a polymer of length L, the high temperature phase is characterized by a diffusive behavior for the end-point displacement R2 ˜L and by free-energy fluctuations of order ΔF(L) ˜O(1). The low-temperature phase is characterized by an anomalous wandering exponent R2/L ˜Lω and by free-energy fluctuations of order ΔF(L) ˜Lω where ω˜0.18. In this paper, we first study the scaling behavior of various properties to localize the critical temperature Tc. Our results concerning R2/L and ΔF(L) point towards 0.76 < Tc ≤T2=0.79, so our conclusion is that Tc is equal or very close to the upper bound T2 derived by Derrida and coworkers (T2 corresponds to the temperature above which the ratio bar{Z_L^2}/(bar{Z_L})^2 remains finite as L ↦ ∞). We then present histograms for the free-energy, energy and entropy over disorder samples. For T ≫Tc, the free-energy distribution is found to be Gaussian. For T ≪Tc, the free-energy distribution coincides with the ground state energy distribution, in agreement with the zero-temperature fixed point picture. Moreover the entropy fluctuations are of order ΔS ˜L1/2 and follow a Gaussian distribution, in agreement with the droplet predictions, where the free-energy term ΔF ˜Lω is a near cancellation of energy and entropy contributions of order L1/2.

  5. Topical Clonazepam Solution for the Management of Burning Mouth Syndrome: A Retrospective Study.

    PubMed

    Kuten-Shorrer, Michal; Treister, Nathaniel S; Stock, Shannon; Kelley, John M; Ji, Yisi D; Woo, Sook-Bin; Lerman, Mark A; Palmason, Stefan; Sonis, Stephen T; Villa, Alessandro

    2017-01-01

    To evaluate and compare the effectiveness of two concentrations of topical clonazepam solution in improving symptoms of burning mouth syndrome (BMS). A retrospective chart review was conducted of patients diagnosed with BMS and managed with topical clonazepam solution between 2008 and 2015. A 0.5-mg/mL solution was prescribed until 2012, when this was changed to a 0.1 mg/mL solution. Patients were instructed to swish with 5 mL for 5 minutes and spit two to four times daily. The efficacies of the two concentrations were compared using patient-reported outcome measures at the first follow-up, including the reported percentage of improvement in burning symptoms and the change in burning severity from baseline ranked on an 11-point numeric rating scale (NRS). Response to treatment was compared between the two concentrations using Wilcoxon rank sum test. A total of 57 subjects were included, 32 in the 0.1-mg/mL cohort and 25 in the 0.5-mg/mL cohort, and evaluated at a median follow-up of 7 weeks. The median overall percentage improvement was 32.5% in the 0.1-mg/mL cohort and 75% in the 0.5-mg/mL cohort. The median reduction in NRS score was 0.5 points in the 0.1-mg/mL cohort and 6 points in the 0.5-mg/mL cohort. The use of either outcome measure revealed that the response to treatment with the 0.5-mg/mL solution was superior to that of the 0.1 mg/mL solution (P < .01). These findings suggest that a 0.5-mg/mL topical clonazepam solution is effective in the management of BMS. Future randomized clinical trials are warranted.

  6. Pharmacokinetics and tolerability of oral dosage forms of huperzine a in healthy Chinese male volunteers: a randomized, single dose, three-period, six-sequence crossover study.

    PubMed

    Wu, San-Lan; Gan, Jun; Rao, Jing; He, Si-Jie; Zhu, Wen-Wen; Zhao, Ying; Lv, Yong-Ning; Huang, Jian-Geng; Liu, Ya-Ni

    2017-10-01

    Huperzine A is a potent, reversible, and blood-brain barrier permeable acetylcholinesterase inhibitor. The aim of this study was to compare the pharmacokinetics, tolerability, and bioavailability of two formulations with the established reference formulation of huperzine A in a fasting, healthy Chinese male population. This was a randomized, single-dose, 3-period, 6-sequence crossover study. The plasma concentrations of huperzine A were determined by liquid chromatography tandem mass spectrometry. Tolerability was assessed based on subject interview, vital sign monitoring, physical examination, and routine blood and urine tests. The mean (SD) pharmacokinetic parameters of the reference drug were C max , 1.550 (0.528) ng/mL; t 1/2 , 12.092 (1.898) h; AUC 0-72h , 17.550 (3.794) ng·h/mL. Those of the test formulation A and test formulation B were C max , 1.412 (0.467), 1.521 (0.608) ng/mL; t 1/2 , 12.073 (2.068), 12.271 (1.678) h; AUC 0-72h , 15.286 (3.434) ng·h/mL, 15.673 (3.586) ng·h/mL. The 90% confidence intervals for the AUC 0-72h and C max were between 0.80 and 1.25. No adverse events were reported by the subjects or found with results of clinical laboratory test. The test and reference products met the regulatory criteria for bioequivalence in these fasting, healthy Chinese male volunteers. All three formulations appeared to be well tolerated.

  7. Leave or Stay as a Risky Choice: Effects of Salary Reference Points and Anchors on Turnover Intention

    PubMed Central

    Xiong, Guanxing; Wang, X. T.; Li, Aimei

    2018-01-01

    Within a risky choice framework, we examine how multiple reference points and anchors regulate pay perception and turnover intentions in real organizational contexts with actual employees. We hypothesize that the salary range is psychologically demarcated by three reference points into four regions, the minimum requirement (MR), the status quo (SQ), and the goal (G). Three studies were conducted: Study 1 analyzed the relationship between turnover intention and the subjective likelihood of falling into each of four expected salary regions; Study 2 tested the mediating effect of pay satisfaction on salary reference point-dependent turnover intention; and Study 3 explored the anchoring effect of estimated peer salaries. The results show that turnover intention was higher in the region below MR or between SQ and G but lower in the region above G or between MR and SQ. That is, turnover intention can be high even in situations of salary raise, if the raise is below a salary goal (i.e., leaving for a lack of opportunity) and low even in situations of salary loss, if the expected salary is still above the MR (i.e., staying for security). In addition, turnover intention was regulated by pay satisfaction and peer salaries. In conclusion, turnover intention can be viewed as a risky choice adapted to salary reference points. PMID:29872409

  8. Enhancing Foreign Language Learning through Listening Strategies Delivered in L1: An Experimental Study

    ERIC Educational Resources Information Center

    Bozorgian, Hossein; Pillay, Hitendra

    2013-01-01

    Listening used in language teaching refers to a complex process that allows us to understand spoken language. The current study, conducted in Iran with an experimental design, investigated the effectiveness of teaching listening strategies delivered in L1 (Persian) and its effect on listening comprehension in L2. Five listening strategies:…

  9. Pollutant loads and water quality in streams of heavily populated and industrialised towns

    NASA Astrophysics Data System (ADS)

    Ntengwe, F. W.

    The availability of portable water is often taken for granted and water allowed to get polluted. Industries, settlements, farms, markets, leaking sewer lines, poor hygiene practices are all potential sources of pollution. Each pollutant has its own effect on water and the environment. A study was conducted in Kitwe Stream in order to establish whether engineering and other human activities affect water quality. Samples were collected at ten points, the first point being at the source while the tenth point was at the confluence with the Kafue River. The samples were analysed for physical, chemical and biological parameters. The results revealed high levels of concentration and loads of total suspended solids (TSS). The points with high TSS values were P4 (118 mg/l) and P6 (140 mg/l) representing daily loads of 7.74 and 8.71 tonnes, respectively. The highest values of coliform were found at points P9 (2099), P10 (2558) followed by P4 (1149), P5 (1256) and P6 (1370). High values of nitrites were found at points P4 (34 mg/l), P5 (32 mg/l), P6 (21 mg/l) and P10 (12.4 mg/l). Chlorides were also found to be high at points P4, P5 and P6 with values of 70 mg/l, 80 mg/l and 87 mg/l, respectively. These parameters exceeded the maximum contaminant level (MCL) of 100 mg/l for TSS, 1 mg/l for nitrites, 500/100 ml for coliform in Zambia. The conductivity and coliform were also found to be high (>500 μS/cm, >500). The benthic study revealed a normal diversity of invertebrates but chironomidae was found to be on average 60% of total species counted. The fish activity was high upstream and low downstream at the mouth of the stream where it joins the Kafue River. There was no fish activity at the middle points. The planktons (phytoplankton and zooplankton) count revealed a high count (15-30 per ml) in places where there was high fish activity and a low count (1-5 per ml) where there was no activity. The stream water quality was therefore affected by the human activities.

  10. [Comment on “The Paradigm: Thomas Kuhn and the Trojan horse”] Comment: The finer points of mythology and science; Reply: Ajax, Hector, and Pandarus

    NASA Astrophysics Data System (ADS)

    Advocate, Dev L.

    Kingsley Amis once (or perhaps twice) observed, “If you can't annoy somebody with what you write I think there is little point in writing.” Ajax L. East gives some very sound advice: “always verify your references.” This quote is not quite right and is taken out of context. Dr. Routh, when asked for some advice by a young man, replied, “I think, sir, since you care for the advice of an old man sir, you will find it a very good practice always to verify your references, sir.” This advice was offered thoughtfully and not gratuitously, out of the blue, or whatever color cyberspace is. So, it is good to verify your references. Ironically, in my account of the Trojan War, I did not refer to Homer, or the Iliad, and certainly not to an English translation or the long lost Nostoi. My sources were more eclectic and original, not that I have anything against Homer or Lattimore. Students of the Trojan War must distinguish between myth, legend, history, archeology, metaphor, parable, allegory, and geophysics. Homer, of course, takes liberties. Chieftains ride up to battle in chariots, dismount, and exchange quite long speeches before engaging in gruesome hand-to-hand combat.

  11. Effect of triflumuron, a chitin synthesis inhibitor, on Aedes aegypti, Aedes albopictus and Culex quinquefasciatus under laboratory conditions

    PubMed Central

    2013-01-01

    Background Resistance to traditional insecticides represents a threat to the control of disease vectors. The insect growth regulators (IGR) are a potential alternative to control mosquitoes, including resistant populations. The chitin synthesis inhibitors (CSI) are IGRs, which interfere with the insect molting process and represent one major class of compounds against Aedes aegypti populations resistant to the larvicide organophosphate temephos. In the present study, we evaluated the efficacy of the CSI triflumuron on Culex quinquefasciatus, Aedes albopictus and against several Ae. aegypti field populations. Methods The efficacy of triflumuron, against Cx. quinquefasciatus and Ae. albopictus was evaluated with laboratory strains through dose–response assays. Additionaly, this CSI was tested against seven Ae. aegypti field populations exhibiting distinct resistance levels to both temephos and the pyrethroid deltamethrin. Aedes aegypti populations were exposed to both a dose that inhibits 99% of the adult emergence of mosquitoes from the susceptible reference strain, Rockefeller, (EI99 = 3.95 μg/L) and the diagnostic dose (DD), corresponding to twice the EI99. Results Our results indicate that triflumuron was effective in emergence inhibition (EI) of Cx. quinquefasciatus (EI50= 5.28 μg/L; EI90= 12.47 μg/L) and Ae. albopictus (EI50= 1.59 μg/L; EI90= 2.63 μg/L). Triflumuron was also effective against seven Ae. aegypti Brazilian populations resistant to both temephos and deltamethrin. Exposure of all the Ae. aegypti populations to the triflumuron EI99 of the susceptible reference strain, Rockefeller, resulted in complete inhibition of adult emergence, suggesting no cross-resistance among traditional insecticides and this CSI. However, a positive correlation between temephos resistance and tolerance to triflumuron was observed. Conclusion The results suggest that triflumuron represents a potential tool for the control of disease vectors in public health. Nevertheless, they point to the need of constant monitoring of the susceptibility status of vector populations to CSIs. PMID:23557173

  12. Bevalac Ion Beam Characterizations for Single Event Phenomena

    DTIC Science & Technology

    1992-07-16

    site. 13 REFERENCES 1. T. L. Criswell, P. R. Measel and K. L. Wablin, "Single Event Upset Testing with Relativistic Heavy Ions," IEEE Trans. Nucl. Sci...NS-31, 1559-1563, (1984). 2. T. L. Criswell, D. L. Oberg, J. L. Wert, P. R. Measel , and W. E. Wilson, "Measurement of SEU Thresholds and Cross

  13. 40 CFR 63.150 - Emissions averaging provisions.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Group 1 emission points to which the reference control technology (defined in § 63.111 of this subpart... prevention measure is used in conjunction with other controls for a Group 1 emission point, the pollution... which case credit will be allowed only for the increase in control after November 15, 1990. (2) Group 1...

  14. 40 CFR 63.150 - Emissions averaging provisions.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Group 1 emission points to which the reference control technology (defined in § 63.111 of this subpart... prevention measure is used in conjunction with other controls for a Group 1 emission point, the pollution... which case credit will be allowed only for the increase in control after November 15, 1990. (2) Group 1...

  15. 40 CFR 63.150 - Emissions averaging provisions.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Group 1 emission points to which the reference control technology (defined in § 63.111 of this subpart... prevention measure is used in conjunction with other controls for a Group 1 emission point, the pollution... which case credit will be allowed only for the increase in control after November 15, 1990. (2) Group 1...

  16. 40 CFR 63.150 - Emissions averaging provisions.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Group 1 emission points to which the reference control technology (defined in § 63.111 of this subpart... prevention measure is used in conjunction with other controls for a Group 1 emission point, the pollution... which case credit will be allowed only for the increase in control after November 15, 1990. (2) Group 1...

  17. 40 CFR 63.150 - Emissions averaging provisions.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Group 1 emission points to which the reference control technology (defined in § 63.111 of this subpart... prevention measure is used in conjunction with other controls for a Group 1 emission point, the pollution... which case credit will be allowed only for the increase in control after November 15, 1990. (2) Group 1...

  18. Archaeological Test Sampling of Sites within the La Quinta Flood Control Channel Easement,

    DTIC Science & Technology

    1980-03-01

    J L CRAIB MAR 80UNCLASSIFIED DACW@9-80-M-0975 F/G 5/6 NL | EmhhhhhhommhhlmEEIE hhhhhl I E5Ehhhhhhhhlh IIllfllfflfflffllfllf U-IIIIII a J 12 !EM imi.I...ima ii~ti -- I .u 1111125 11114 111116 MICROCOPY RESOLUTION TEST CHART NATIONAL BUR.AU OF STANDARDS-1963- A K- Lo’ • ~ ~ ~ ~ ~ ~ ~ ~ e 4e...66 REFERENCES CITED ............................................... 71 APPENDIX A - Triangulation Points for Site Datum Stakes ........ 73

  19. A clinical-molecular prognostic model to predict survival in patients with post polycythemia vera and post essential thrombocythemia myelofibrosis.

    PubMed

    Passamonti, F; Giorgino, T; Mora, B; Guglielmelli, P; Rumi, E; Maffioli, M; Rambaldi, A; Caramella, M; Komrokji, R; Gotlib, J; Kiladjian, J J; Cervantes, F; Devos, T; Palandri, F; De Stefano, V; Ruggeri, M; Silver, R T; Benevolo, G; Albano, F; Caramazza, D; Merli, M; Pietra, D; Casalone, R; Rotunno, G; Barbui, T; Cazzola, M; Vannucchi, A M

    2017-12-01

    Polycythemia vera (PV) and essential thrombocythemia (ET) are myeloproliferative neoplasms with variable risk of evolution into post-PV and post-ET myelofibrosis, from now on referred to as secondary myelofibrosis (SMF). No specific tools have been defined for risk stratification in SMF. To develop a prognostic model for predicting survival, we studied 685 JAK2, CALR, and MPL annotated patients with SMF. Median survival of the whole cohort was 9.3 years (95% CI: 8-not reached-NR-). Through penalized Cox regressions we identified negative predictors of survival and according to beta risk coefficients we assigned 2 points to hemoglobin level <11 g/dl, to circulating blasts ⩾3%, and to CALR-unmutated genotype, 1 point to platelet count <150 × 10 9 /l and to constitutional symptoms, and 0.15 points to any year of age. Myelofibrosis Secondary to PV and ET-Prognostic Model (MYSEC-PM) allocated SMF patients into four risk categories with different survival (P<0.0001): low (median survival NR; 133 patients), intermediate-1 (9.3 years, 95% CI: 8.1-NR; 245 patients), intermediate-2 (4.4 years, 95% CI: 3.2-7.9; 126 patients), and high risk (2 years, 95% CI: 1.7-3.9; 75 patients). Finally, we found that the MYSEC-PM represents the most appropriate tool for SMF decision-making to be used in clinical and trial settings.

  20. Nonylphenol ethoxylates and other additives in aircraft deicers, antiicers, and waters receiving airport runoff.

    PubMed

    Corsi, Steven R; Zitomer, Daniel H; Field, Jennifer A; Cancilla, Devon A

    2003-09-15

    Samples of nine different formulations of aircraft deicer and antiicer fluids (ADAF) were screened for the presence of selected surfactants. Nonylphenol ethoxylates (NPnEO) were identified in three ADAF formulations, octylphenol ethoxylates were identified in two formulations, and six formulations contained alcohol ethoxylates. A preliminary field study was conducted at General Mitchell International Airport, Milwaukee, WI, to quantify NPnEO (n = 1-15) and one of its byproducts, nonylphenol (NP), in airport runoff. Samples were collected from two airport outfalls, from the receiving stream, and from an upstream reference site during intensive ADAF application events. NPnEO was measured at concentrations up to 1190microg/L in airport outfall samples, up to 77 ug/L in samples from the receiving stream and less than 5.0 microg/L from the upstream reference. Concentrations of glycol and other ADAF-related constituents, including NPnEO, were reduced by approximately 1 order of magnitude between the outfall sites and the receiving stream site; however, concentrations of NP in the receiving stream remained similar to those from the outfalls (< 0.04 microg/L at the upstream reference, 0.98 and 7.67 microg/L at outfalls, and 3.89 microg/L in the receiving stream). The field data suggest that NP is generated through degradation of NPnEO from airport runoff.

  1. Nonylphenol ethoxylates and other additives in aircraft deicers, antiicers, and waters receiving airport runoff

    USGS Publications Warehouse

    Corsi, Steven R.; Zitomer, Daniel H.; Field, Jennifer A.; Cancilla, Devon A.

    2003-01-01

    Samples of nine different formulations of aircraft deicer and antiicer fluids (ADAF) were screened for the presence of selected surfactants. Nonylphenol ethoxylates (NPnEO) were identified in three ADAF formulations, octylphenol ethoxylates were identified in two formulations, and six formulations contained alcohol ethoxylates. A preliminary field study was conducted at General Mitchell International Airport, Milwaukee, WI, to quantify NPnEO (n = 1-15) and one of its byproducts, nonylphenol (NP), in airport runoff. Samples were collected from two airport outfalls, from the receiving stream, and from an upstream reference site during intensive ADAF application events. NPnEO was measured at concentrations up to 1190microg/L in airport outfall samples, up to 77 ug/L in samples from the receiving stream and less than 5.0 microg/L from the upstream reference. Concentrations of glycol and other ADAF-related constituents, including NPnEO, were reduced by approximately 1 order of magnitude between the outfall sites and the receiving stream site; however, concentrations of NP in the receiving stream remained similar to those from the outfalls (< 0.04 microg/L at the upstream reference, 0.98 and 7.67 microg/L at outfalls, and 3.89 microg/L in the receiving stream). The field data suggest that NP is generated through degradation of NPnEO from airport runoff.

  2. 10-year cumulative and bidirectional associations of domain-specific physical activity and sedentary behaviour with health-related quality of life in French adults: Results from the SU.VI.MAX studies.

    PubMed

    Omorou, Abdou Y; Vuillemin, Anne; Menai, Medhi; Latarche, Clotilde; Kesse-Guyot, Emmanuelle; Galan, Pilar; Hercberg, Serge; Oppert, Jean-Michel; Briançon, Serge

    2016-07-01

    The directionality of the associations of domain-specific physical activity (PA) and sedentary behaviour (SB) with health-related quality of life (HRQoL) in adults remain insufficiently known. This study investigated the longitudinal associations of 10-year cumulative levels of PA and SB with HRQoL and the reverse associations. A sample of 2093 (47.8% men) participants from a cohort of French adult (SU.VI.MAX) was included. Data were collected at 3 time points (1998, 2001 and 2007) using the Modifiable Activity Questionnaire (MAQ) for PA (leisure-time and occupational) and SB (screen-viewing, reading and total sitting time) and the DUKE Health Profile for HRQoL. The cumulative level (from 0 to 3) referred to the number of time points where a high PA level, high SB or good HRQoL was reported. Regression models examined the 10-year cumulative level of PA, SB as predictors of HRQoL and reverse associations. The 10-year cumulative level of high PA, both leisure-time and occupational, predicted a higher HRQoL while the 10-year cumulative level of high screen-viewing time and high total sitting time was associated with lower HRQoL. For the reverse association, cumulative level of good HRQoL predicted more leisure-time PA, less screen-viewing time and less total sitting time but was not related to occupational PA. Relationships between PA, SB and HRQoL are complex and should not be oversimplified in one or the other direction. Taking into account domain-specific PA and SB in health promotion programs appears of prime importance to design interventions aiming at improving HRQoL. Copyright © 2016 Elsevier Inc. All rights reserved.

  3. Montgomery Point Lock and Dam, White River, Arkansas

    DTIC Science & Technology

    2016-01-01

    ER D C/ CH L TR -1 6- 1 Monitoring Completed Navigation Projects (MCNP) Program Montgomery Point Lock and Dam, White River, Arkansas Co...Navigation Projects (MCNP) Program ERDC/CHL TR-16-1 January 2016 Montgomery Point Lock and Dam, White River, Arkansas Allen Hammack, Michael Winkler, and...20314-1000 Under MCNP Work Unit: Montgomery Point Lock and Dam, White River, Arkansas ERDC/CHL TR-16-1 ii Abstract Montgomery Point Lock and

  4. On the output factor measurements of the CyberKnife iris collimator small fields: Experimental determination of the k{sub Q{sub c{sub l{sub i{sub n,Q{sub m{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub m}{sub s}{sub r}}}}}}}}} correction factors for microchamber and diode detectors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pantelis, E.; Moutsatsos, A.; Zourari, K.

    Purpose: To measure the output factors (OFs) of the small fields formed by the variable aperture collimator system (iris) of a CyberKnife (CK) robotic radiosurgery system, and determine the k{sub Q{sub c{sub l{sub i{sub n,Q{sub m{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub m}{sub s}{sub r}}}}}}}}} correction factors for a microchamber and four diode detectors. Methods: OF measurements were performed using a PTW PinPoint 31014 microchamber, four diode detectors (PTW-60017, -60012, -60008, and the SunNuclear EDGE detector), TLD-100 microcubes, alanine dosimeters, EBT films, and polymer gels for the 5 mm, 7.5 mm, 10 mm, 12.5 mm, and 15 mm irismore » collimators at 650 mm, 800 mm, and 1000 mm source to detector distance (SDD). The alanine OF measurements were corrected for volume averaging effects using the 3D dose distributions registered in polymer gel dosimeters. k{sub Q{sub c{sub l{sub i{sub n,Q{sub m{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub m}{sub s}{sub r}}}}}}}}} correction factors for the PinPoint microchamber and the diode dosimeters were calculated through comparison against corresponding polymer gel, EBT, alanine, and TLD results. Results: Experimental OF results are presented for the array of dosimetric systems used. The PinPoint microchamber was found to underestimate small field OFs, and a k{sub Q{sub c{sub l{sub i{sub n,Q{sub m{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub m}{sub s}{sub r}}}}}}}}} correction factor ranging from 1.127 {+-} 0.022 (for the 5 mm iris collimator) to 1.004 {+-} 0.010 (for the 15 mm iris collimator) was determined at the reference SDD of 800 mm. The PinPoint k{sub Q{sub c{sub l{sub i{sub n,Q{sub m{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub m}{sub s}{sub r}}}}}}}}} correction factor was also found to increase with decreasing SDD; k{sub Q{sub c{sub l{sub i{sub n,Q{sub m{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub m}{sub s}{sub r}}}}}}}}} values equal to 1.220 {+-} 0.028 and 1.077 {+-} 0.016 were obtained for the 5 mm iris collimator at 650 mm and 1000 mm SDD, respectively. On the contrary, diode detectors were found to overestimate small field OFs and a correction factor equal to 0.973 {+-} 0.006, 0.954 {+-} 0.006, 0.937 {+-} 0.007, and 0.964 {+-} 0.006 was measured for the PTW-60017, -60012, -60008 and the EDGE diode detectors, respectively, for the 5 mm iris collimator at 800 mm SDD. The corresponding correction factors for the 15 mm iris collimator were found equal to 0.997 {+-} 0.010, 0.994 {+-} 0.009, 0.988 {+-} 0.010, and 0.986 {+-} 0.010, respectively. No correlation of the diode k{sub Q{sub c{sub l{sub i{sub n,Q{sub m{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub m}{sub s}{sub r}}}}}}}}} correction factors with SDD was observed. Conclusions: This work demonstrates an experimental procedure for the determination of the k{sub Q{sub c{sub l{sub i{sub n,Q{sub m{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub m}{sub s}{sub r}}}}}}}}} correction factors required to obtain small field OF results of increased accuracy.« less

  5. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cheng, Yue; Yang, Meng-Lin; Hu, Huai-Ming, E-mail: ChemHu1@NWU.EDU.CN

    Six new coordination polymers, [ZnLCl]{sub n}(1), [ZnL{sub 2}]{sub n}·2nH{sub 2}O (2), [Zn{sub 2}L(o-bdc)(OH)]{sub n}·0.5nH{sub 2}O (3), [Zn{sub 2}L(m-bdc)(OH)]{sub n}·nH{sub 2}O (4), [Zn{sub 2}L{sub 2}(p-bdc) (H{sub 2}O){sub 2}]{sub n}·nH{sub 2}O (5), [Zn{sub 2}L(1,2,4-btc)(H{sub 2}O)]{sub n}(6), (HL=4′-(3-carboxyphenyl)- 3,2′:6′,3″-terpyridine, H{sub 2}(o-bdc)= benzene-1,2-dicarboxylic acid, H{sub 2}(m-bdc)= benzene-1,3-dicarboxylic acid, H{sub 2}(p-bdc)= benzene-1,4-dicarboxylic acid, H{sub 3}(1,2,4-btc)= benzene-1,2,4-tricarboxylic acid) have been synthesized under the hydrothermal conditions. Compound 1 displays a 3-connected 2D network structure with point symbol of {8"2.10}. Compound 2 exhibits 1D infinite loop chain structure. Compound 3 possesses a (3,8)-connected 3D framework composed of tetranuclear units with point symbol of {4"3}{sub 2}{4"6.6"1"8.8"4}. Compound 4 featuresmore » a typical 2D hcb network based on tetranuclear zinc(II) units with point symbol of {4"4.6"2}. Compound 5 presents a classical two-fold penetration sql network with point symbol of {6"3}. Compound 6 can be seen as a (3,3,6)-connected 3D net with point symbol of {4"2.6"4.8"9}{4"2.6}{6"3}. The thermal stability and luminescent properties of compounds 1–6 in the solid state are discussed in detail. - Graphical abstract: Six new Zn(II) coordination polymers based on multicarboxylate and terpyridyl derivative ligands have synthesized under the hydrothermal conditions and the thermal stability and luminescence are discussed. Display Omitted.« less

  6. The Cerebro-oculo-facio-skeletal Syndrome Point Mutation F231L in the ERCC1 DNA Repair Protein Causes Dissociation of the ERCC1-XPF Complex*

    PubMed Central

    Faridounnia, Maryam; Wienk, Hans; Kovačič, Lidija; Folkers, Gert E.; Jaspers, Nicolaas G. J.; Kaptein, Robert; Hoeijmakers, Jan H. J.; Boelens, Rolf

    2015-01-01

    The ERCC1-XPF heterodimer, a structure-specific DNA endonuclease, is best known for its function in the nucleotide excision repair (NER) pathway. The ERCC1 point mutation F231L, located at the hydrophobic interaction interface of ERCC1 (excision repair cross-complementation group 1) and XPF (xeroderma pigmentosum complementation group F), leads to severe NER pathway deficiencies. Here, we analyze biophysical properties and report the NMR structure of the complex of the C-terminal tandem helix-hairpin-helix domains of ERCC1-XPF that contains this mutation. The structures of wild type and the F231L mutant are very similar. The F231L mutation results in only a small disturbance of the ERCC1-XPF interface, where, in contrast to Phe231, Leu231 lacks interactions stabilizing the ERCC1-XPF complex. One of the two anchor points is severely distorted, and this results in a more dynamic complex, causing reduced stability and an increased dissociation rate of the mutant complex as compared with wild type. These data provide a biophysical explanation for the severe NER deficiencies caused by this mutation. PMID:26085086

  7. Determination of yeast assimilable nitrogen content in wine fermentations by sequential injection analysis with spectrophotometric detetection.

    PubMed

    Muik, Barbara; Edelmann, Andrea; Lendl, Bernhard; Ayora-Cañada, María José

    2002-09-01

    An automated method for measuring the primary amino acid concentration in wine fermentations by sequential injection analysis with spectrophotometric detection was developed. Isoindole-derivatives from the primary amino acid were formed by reaction with o-phthaldialdehyde and N-acetyl- L-cysteine and measured at 334 nm with respect to a baseline point at 700 nm to compensate the observed Schlieren effect. As the reaction kinetic was strongly matrix dependent the analytical readout at the final reaction equilibrium has been evaluated. Therefore four parallel reaction coils were included in the flow system to be capable of processing four samples simultaneously. Using isoleucine as the representative primary amino acid in wine fermentations a linear calibration curve from 2 to 10 mM isoleucine, corresponding to 28 to 140 mg nitrogen/L (N/L) was obtained. The coefficient of variation of the method was 1.5% at a throughput of 12 samples per hour. The developed method was successfully used to monitor two wine fermentations during alcoholic fermentation. The results were in agreement with an external reference method based on high performance liquid chromatography. A mean-t-test showed no significant differences between the two methods at a confidence level of 95%.

  8. Quality of life in high-risk patients: comparison of transcatheter aortic valve implantation with surgical aortic valve replacement.

    PubMed

    Amonn, Kathrin; Stortecky, Stefan; Brinks, Henriette; Gahl, Brigitta; Windecker, Stephan; Wenaweser, Peter; Carrel, Thierry; Huber, Christoph

    2013-01-01

    To compare health-related quality of life (QoL) in patients undergoing transcatheter aortic valve implantation via transapical access (TA TAVI) with patients undergoing surgical aortic valve replacement (SAVR). One hundred and forty-four high-risk patients referred for aortic valve replacement underwent TAVI screening and were assigned to either TA TAVI (n = 51, age 79.7 ± 9.2 years, logistic EuroSCORE 26.5 ± 16.1%, 51% males) or SAVR (n = 93, age 81.1 ± 5.3 years, logistic EuroSCORE 12.1 ± 9.3%, 42% males) by the interdisciplinary heart team. QoL was assessed using the Short Form 36 (SF-36) Health Survey Questionnaire and the Hospital Anxiety and Depression Scale. Furthermore, current living conditions and the degree of independence at home were evaluated. Patients undergoing TA TAVI were at higher risk as assessed by EuroSCORE (26.5 ± 16 vs. 12.1 ± 9, P < 0.001) and STS score (6.7 ± 4 vs. 4.4 ± 3, P < 0.001) compared with SAVR patients. At the 30-day follow-up, the rate of mortality was similar and amounted to 7.8% for TA TAVI and 7.5% for SAVR patients and raised to 25.5% in TA TAVI and 18.3% in SAVR patients after a follow-up period of 15 ± 10 months. Assessment of QoL revealed no differences in terms of anxiety and depression between TA TAVI and SAVR patients. The SF-36 mental health metascore was similar in both groups (65.6 ± 19 vs. 68.8 ± 22, P = 0.29), while a significant difference was observed in the physical health metascore (49.7 ± 21 vs. 62.0 ± 21, P = 0.015). After adjustment for baseline characteristics, this difference disappeared. However, every added point in the preoperative risk assessment with the STS score decreased the SF-36 physical health dimension by two raw points at the follow-up assessment. Selected high-risk patients undergoing TAVI by using a transapical access achieve similar clinical outcomes and QoL compared with patients undergoing SAVR. Increased STS scores predict worse QoL outcomes.

  9. Genetics Home Reference: 1q21.1 microdeletion

    MedlinePlus

    ... Baralle D, Collins A, Mercer C, Norga K, de Ravel T, Devriendt K, Bongers EM, de Leeuw N, Reardon W, Gimelli S, Bena F, Hennekam ... Lilley C, Armengol L, Spysschaert Y, Verloo P, De Coene A, Goossens L, Mortier G, Speleman F, ...

  10. Genetics Home Reference: 1q21.1 microduplication

    MedlinePlus

    ... Baralle D, Collins A, Mercer C, Norga K, de Ravel T, Devriendt K, Bongers EM, de Leeuw N, Reardon W, Gimelli S, Bena F, Hennekam ... Lilley C, Armengol L, Spysschaert Y, Verloo P, De Coene A, Goossens L, Mortier G, Speleman F, ...

  11. 3D-RTK Capability of Single Gnss Receivers

    NASA Astrophysics Data System (ADS)

    Stempfhuber, W.

    2013-08-01

    Small, aerial objects are now being utilised in many areas of civil object capture and monitoring. As a rule, the standard application of a simple GPS receiver with code solutions serves the 3D-positioning of the trajectories or recording positions. Without GPS correction information, these can be calculated at an accuracy of 10-20 metres. Corrected code solutions (DGPS) generally lie in the metre range. A precise 3D-positioning of the UAV (unmanned aerial vehicle) trajectories in the centimetre range provides significant improvements. In addition, the recording time of each sensor can be synchronized with the exact time stamp of the GNSS low-cost system. In recent years, increasing works on positioning from L1 GPS raw data have been published. Along with this, the carrier phase measurements with the established evaluation algorithms are analysed in the post processing method to centimetre-exact positions or to high-precision 3D trajectories [e.g. Schwieger and Gläser, 2005 or Korth and Hofmann 20011]. The use of reference information from local reference stations or a reference network serves the purpose of carrier phase ambiguity resolution. Furthermore, there are many activities worldwide in the area of PPP techniques (Precise Point Positioning). However, dual frequency receivers are primarily used in this instance. Moreover, very long initialisation times must be scheduled for this. A research project on the subject of low-cost RTK GNSS was developed for real-time applications at the Beuth Hochschule für Technik Berlin University of Applied Sciences [Stempfhuber 2012]. The overall system developed for the purpose of real-time applications with centimetre accuracy is modularly constructed and can be used for various applications (http://prof.beuthhochschule.de/stempfhuber/seite-publikation/). With hardware costing a few hundred Euro and a total weight of 500-800 g (including the battery), this system is ideally suited for UAV applications. In addition, the GNSS data processed with the RTK method can be provided in standardised NMEA format. Through the reduced shadowing effects of the aerial objects, GNSS external factors such as multipath cause few problems. With L1 carrier phase analysis, the baseline computation must nevertheless remain limited at the range of a few kilometres. With distances of more than 5 kilometres between the reference station and the rover station position, mistakes arise in the decimetre area. The overall modular system consists of a low-cost, single-frequency receiver (e.g. uBlox LEA4T or 6T receiver), a L1 antenna (e.g. the Trimble Bullet III), a developed data logger including an integrated WLAN communication module for storage and securing of the raw data as well as a power supply. Optimisation of the L1 antenna has shown that, in this instance, many problems relating to signal reception can be reduced. A calibration of the choke-ring adaptors for various antenna calibration facilities results in good and homogeneous antenna parameters. In this situation, the real-time algorithm from the Open Source project RTKLib [Takasu, 2010] generally runs on a small computer at the reference station. In this case, the data transfer from the L1 receiver to the PC is realisable through a serial cable. The rover station can transfer the raw data to the computing algorithm over a WLAN network or through a data radio. Of course, this computational algorithm can also be adapted to an integrated computing module for L1 carrier phase resolutions. The average time to first fix (TTFF) amounts to a few minutes depending on the satellite constellation. Different test series in movement simulators and in moving objects have shown that a stable, fixed solution is achieved with a normal satellite constellation. A test series with a Microdrones quadrocopter could also be conducted. In comparison of the RTK positions with a geodetic dual frequency receiver, differences are in millimetre ranges. In addition, reference systems (based on total stations) are present for the precise examination of the kinematically captured positioning [Eisenbeiss et al. 2009].

  12. Comparing L1 and L2 Texts and Writers in First-Year Composition

    ERIC Educational Resources Information Center

    Eckstein, Grant; Ferris, Dana

    2018-01-01

    Scholars have at various points discussed the needs of second language (L2) writers enrolled in "mainstream" composition courses where they are mixed with native (L1) English speakers. Other researchers have investigated the experiences of L2 writers in mainstream classes and the perceptions of their instructors about their abilities and…

  13. Pharmacokinetics and Bioequivalence of Two Formulations of Febuxostat 40-Mg and 80-Mg Tablets: A Randomized, Open-Label, 4-Way Crossover Study in Healthy Chinese Male Volunteers

    PubMed Central

    Luo, Zhu; Nan, Feng; Miao, Jia; Chen, Zhihui; Li, Mei; Liang, Maozhi

    2016-01-01

    The present study aimed to investigate the pharmacokinetic properties of febuxostat in healthy Chinese male volunteers and evaluate whether the two formulations of febuxostat 40-mg and 80-mg tablets are bioequivalent. A randomized, open-label, 4-way crossover study was conducted in healthy Chinese male volunteers under fasting conditions. 24 eligible subjects were randomized in a 1:1:1:1 ratio to receive a single dose of test or reference formulation of febuxostat 40-mg or 80-mg tablet. The washout period between each administration was 1 week. Plasma febuxostat was quantified by a validated liquid chromatography-tandem mass spectrometry (LC-MS/MS) method. Tolerability was evaluated by monitoring adverse events, physical examinations, 12-lead ECG and laboratory tests. After single-dosing of 1 tablet of 40-mg febuxostat, the pharmacokinetic parameters of test and reference formulations were: Tmax 1.22±0.87 and 1.85±1.03 h, Cmax 1689.16±461.31 and 1613.80±608.43 ng·mL-1, AUC0-t 5139.87±1349.28 and 5517.91±2024.26 ng·mL-1·h, AUC0−∞ 5263.06±1339.16 and 5640.48±2040.22 ng·mL-1·h, t1/2 4.82±2.61 and 4.85±1.78 h, respectively. After single-dosing of 1 tablet of 80-mg febuxostat, the pharmacokinetic parameters of test and reference formulations were: Tmax 1.71±1.21 and 2.23±1.55 h, Cmax 2744.47±1157.44 and 2998.17±1200.13 ng·mL-1, AUC0-t 9634.03±2768.25 and 10467.95±3501.65 ng·mL-1·h, AUC0−∞ 9834.32±2730.51 and 10626.63±3504.08 ng·mL-1·h, t1/2 6.25±2.44 and 5.46±1.65 h, respectively. For single-dosing of 1 tablet of 40-mg febuxostat, 90% CIs for the test/reference ratio of AUC0-t, AUC0−∞ and Cmax were 89.79 to 102.55, 90.14 to 102.56 and 93.99 to 129.63, respectively. For single-dosing of 1 tablet of 80-mg febuxostat, 90% CIs for the test/reference ratio of AUC0-t, AUC0−∞ and Cmax were 86.67 to 100.00, 87.50 to 100.51 and 79.48 to 105.99, respectively. This single dose study revealed similar pharmacokinetic properties in healthy Chinese male volunteers as those found in Caucasic population. The test and reference febuxostat tablets formulations met the regulatory criteria for bioequivalence at 40-mg and 80-mg strengths in fasting healthy Chinese male volunteers. Trial Registration: Chictr.org ChiCTR-TTRCC-14004288 PMID:26974539

  14. An evaluation of light intensity functions for determination of shaded reference stream metabolism.

    PubMed

    Zell, Chris; Hubbart, Jason A

    2012-04-30

    The performance of three single-station whole stream metabolism models were evaluated within three shaded, seasonally hypoxic, Missouri reference streams using high resolution (15-minute) dissolved oxygen (DO), temperature, and light intensity data collected during the summers (July-September) of 2006-2008. The model incorporating light intensity data consistently achieved a lower root mean square error (median RMSE = 0.20 mg L(-1)) relative to models assuming sinusoidal light intensity functions (median RMSE = 0.28 mg L(-1)) and constant diel temperature (median RMSE = 0.53 mg L(-1)). Incorporation of site-specific light intensity into metabolism models better predicted morning DO concentrations and exposure to hypoxic conditions in shaded study streams. Model choice significantly affected (p < 0.05) rate estimates for daily average photosynthesis. Low reaeration (pooled site mean 1.1 day(-1) at 20 °C) coupled with summer temperatures (pooled site mean = 25.8 °C) and low to moderate community respiration (site median 1.0-3.0 g O(2) m(-2) day(-1)) yielded diel dissolved oxygen concentrations near or below critical aquatic life thresholds in studied reference streams. Quantifying these process combinations in best-available or least-disturbed (i.e., reference) systems advances our understanding of regional dissolved oxygen expectations and informs environmental management policy. Additional research is warranted to better link landscape processes with distributed sources that contribute to community respiration. Copyright © 2011 Elsevier Ltd. All rights reserved.

  15. [Centralization of health services in primary care in summer: Patients and professionals view during two consecutive years].

    PubMed

    Giménez, N; Martínez, J M; Clanchet, T

    2015-01-01

    The Spanish primary health care, gateway and pillar of the Health Care System has his resources increasingly constrained by current crisis. To know the opinion of users and professionals on two primary care centers which centralized in August 2011 and 2012 the attendance of seven primary care centers. Two questionnaires were designed: a telephone survey of a random sample of users and a self-completed questionnaire for health care professionals. The variables were scored on a scale of 1-10 (low to high). Cronbach's coefficient α>0,84. 1293 people responded (836 users and 357 professionals). Users rated, in 2011, the satisfaction with 6.7 points in August and 7.3 points the rest of the year (P<.001). And, in 2012, with 7.7 points in August and 8.1 points the rest of the year (P<.001). Health care professionals, rated their satisfaction with 6.8 points in 2011 and 7.3 points in 2012. The waiting time was the only variable best scores in August that the rest of the year. The perception of the solution given in consultation did not change. Satisfaction, marking, care and treatment were highest rated in the regular center than in the reference center (P<.001). The centralization of primary health care during periods of reduced demand could reduce costs while maintaining quality. The experience of centralizing primary care services during August was perceived as acceptable and improved over time. Users showed a slight, but significant, preference for their usual primary care center. Copyright © 2014 Sociedad Española de Médicos de Atención Primaria (SEMERGEN). Publicado por Elsevier España, S.L.U. All rights reserved.

  16. Estimation of the spatial validity of local aerosol measurements in Europe using MODIS data

    NASA Astrophysics Data System (ADS)

    Marcos, Carlos; Gómez-Amo, J. Luis; Pedrós, Roberto; Utrillas, M. Pilar; Martínez-Lozano, J. Antonio

    2013-04-01

    The actual impact of atmospheric aerosols in the Earth's radiative budget is still associated to large uncertainties [IPCC, 2007]. Global monitoring of the aerosol properties and distribution in the atmosphere is needed to improve our knowledge of climate change. The instrumentation used for this purpose can be divided into two main groups: ground-based and satellite-based. Ground-based instruments, like lidars or Sun-photometers, are usually designed to measure accurate local properties of atmospheric aerosols throughout the day. However, the spatial validity of these measurements is conditioned by the aerosol variability within the atmosphere. Satellite-based sensors offer spatially resolved information about aerosols at a global scale, but generally with a worse temporal resolution and in a less detailed way. In this work, the aerosol optical depth (AOD) at 550nm from MODIS Aqua, product MYD04 [Remer, 2005], is used to estimate the area of validity of local measurements at different reference points, corresponding to the AERONET [Holben, 1998] stations during the 2011-2012 period in Europe. For each case, the local AOD (AODloc) at each reference point is calculated as the averaged MODIS data within a radius of 15 km. Then, the AODloc is compared to the AOD obtained when a larger averaging radius is used (AOD(r)), up to 500 km. Only those cases where more than 50% of the pixels in each averaging area contain valid data are used. Four factors that could affect the spatial variability of aerosols are studied: proximity to the sea, human activity, aerosol load and geographical location (latitude and longitude). For the 76 reference points studied, which are sited in different regions of Europe, we have determined that the root mean squared difference (RMSD) between AODloc and AOD(r) , averaged for all cases, increases in a logarithmic way with the averaging radius (RMSD ? log(r)), while the linear correlation coefficient (R) decreases following a logarithmic trend (R ? -log(r)). Among all the factors studied, the aerosol load is the most influential one in the aerosol spatial variability: for averaging radii smaller than 40 km, the RMSD increases with AODloc. Another important factor is the latitude and longitude: the variation of the RMSD in the AOD with regard to the averaging radius can differ up to a 60%, depending on the location. On the contray, the proximity to the sea and the amount of population surrounding each reference point do not have a noticeable influence compared to the above mentioned factors. Holben, B. N., Eck, T. F., Slutsker, I., Buis, J. P., Setzer, A., Vermote, E., Reagan, J. A., Kaufman, Y., Nakajima, T., Lavenu, F., and Smirnov, A.: AERONET - A federated instrument network and data archive for aerosol characterization, Remote Sens. Environ., 66, 1-16, 1998. IPCC (2007). S. Solomon, D. Qin, M. Manning, Z. Chen, M. Marquis, K.B. Averyt, M. Tignor, H.L. Miller (Eds.), Climate Change 2007: The Physical Science Basis. Contribution of Working Group I to the Fourth Assessment Report of the Intergovernmental Panel on Climate Change. Cambridge University Press, Cambridge, UK & New York, USA. Remer, L. A., y co-authors, 2005: The MODIS aerosol algorithm, products, and validation. J. Atmos. Sci., 62, 947-973. doi: http://dx.doi.org/10.1175/JAS3385.1

  17. Real-time monitoring of inflammation status in 3T3-L1 adipocytes possessing a secretory Gaussia luciferase gene under the control of nuclear factor-kappa B response element

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nagasaki, Haruka; Yoshimura, Takeshi; Aoki, Naohito, E-mail: n-aoki@bio.mie-u.ac.jp

    2012-04-13

    Highlights: Black-Right-Pointing-Pointer Inflammation status in adipocytes can be monitored by the new assay system. Black-Right-Pointing-Pointer Only an aliquot of conditioned medium is required without cell lysis. Black-Right-Pointing-Pointer Inflammation-attenuating compounds can be screened more conveniently. -- Abstract: We have established 3T3-L1 cells possessing a secretory Gaussia luciferase (GLuc) gene under the control of nuclear factor-kappa B (NF-{kappa}B) response element. The 3T3-L1 cells named 3T3-L1-NF-{kappa}B-RE-GLuc could differentiate into adipocyte as comparably as parental 3T3-L1 cells. Inflammatory cytokines such as tumor necrosis factor (TNF)-{alpha} and interleukin (IL)-1{beta} induced GLuc secretion of 3T3-L1-NF-{kappa}B-RE-GLuc adipocytes in a concentration- and time-dependent manner. GLuc secretion of 3T3-L1-NF-{kappa}B-RE-GLucmore » adipocytes was also induced when cultured with RAW264.7 macrophages and was dramatically enhanced by lipopolysaccharide (LPS)-activated macrophages. An NF-{kappa}B activation inhibitor BAY-11-7085 and an antioxidant N-acetyl cysteine significantly suppressed GLuc secretion induced by macrophages. Finally, we found that rosemary-derived carnosic acid strongly suppressed GLuc secretion induced by macrophages and on the contrary up-regulated adiponectin secretion. Collectively, by using 3T3-L1-NF-{kappa}B-RE-GLuc adipocytes, inflammation status can be monitored in real time and inflammation-attenuating compounds can be screened more conveniently.« less

  18. Diagnostic accuracy of refractometry for assessing bovine colostrum quality: A systematic review and meta-analysis.

    PubMed

    Buczinski, S; Vandeweerd, J M

    2016-09-01

    Provision of good quality colostrum [i.e., immunoglobulin G (IgG) concentration ≥50g/L] is the first step toward ensuring proper passive transfer of immunity for young calves. Precise quantification of colostrum IgG levels cannot be easily performed on the farm. Assessment of the refractive index using a Brix scale with a refractometer has been described as being highly correlated with IgG concentration in colostrum. The aim of this study was to perform a systematic review of the diagnostic accuracy of Brix refractometry to diagnose good quality colostrum. From 101 references initially obtain ed, 11 were included in the systematic review meta-analysis representing 4,251 colostrum samples. The prevalence of good colostrum samples with IgG ≥50g/L varied from 67.3 to 92.3% (median 77.9%). Specific estimates of accuracy [sensitivity (Se) and specificity (Sp)] were obtained for different reported cut-points using a hierarchical summary receiver operating characteristic curve model. For the cut-point of 22% (n=8 studies), Se=80.2% (95% CI: 71.1-87.0%) and Sp=82.6% (71.4-90.0%). Decreasing the cut-point to 18% increased Se [96.1% (91.8-98.2%)] and decreased Sp [54.5% (26.9-79.6%)]. Modeling the effect of these Brix accuracy estimates using a stochastic simulation and Bayes theorem showed that a positive result with the 22% Brix cut-point can be used to diagnose good quality colostrum (posttest probability of a good colostrum: 94.3% (90.7-96.9%). The posttest probability of good colostrum with a Brix value <18% was only 22.7% (12.3-39.2%). Based on this study, the 2 cut-points could be alternatively used to select good quality colostrum (sample with Brix ≥22%) or to discard poor quality colostrum (sample with Brix <18%). When sample results are between these 2 values, colostrum supplementation should be considered. Copyright © 2016 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  19. Properties of colour reference solutions of the European Pharmacopoea in CIE L*a*b* colour space.

    PubMed

    Subert, J; Farsa, O; Gajdosová, Z

    2006-12-01

    The coordinates of CIE L*a*b* uniform colour space have been acquired from the transmitance spectra of colour reference solutions of European Pharmacopoeia (Ph.Eur.). Calculation of colour differences of these solutions from purified water deltaE* gave their values in the range between 0.7 (B9 solution) to 36 (Y1 solution) CIE units. Excluding red colour reference soulutions, deltaE* values did not depend on concentrations of colour compounds linearly. Small deltaE* values founded by the brown and brownish-yellow colour reference solutions of the lowest concentrations can possibly cause some problems of visual examination of the degree of coloration of liquids according to Ph.Eur.

  20. Nicotine, acetanilide and urea multi-level2H-,13C- and15N-abundance reference materials for continuous-flow isotope ratio mass spectrometry

    USGS Publications Warehouse

    Schimmelmann, A.; Albertino, A.; Sauer, P.E.; Qi, H.; Molinie, R.; Mesnard, F.

    2009-01-01

    Accurate determinations of stable isotope ratios require a calibration using at least two reference materials with different isotopic compositions to anchor the isotopic scale and compensate for differences in machine slope. Ideally, the S values of these reference materials should bracket the isotopic range of samples with unknown S values. While the practice of analyzing two isotopically distinct reference materials is common for water (VSMOW-SLAP) and carbonates (NBS 19 and L-SVEC), the lack of widely available organic reference materials with distinct isotopic composition has hindered the practice when analyzing organic materials by elemental analysis/isotope ratio mass spectrometry (EA-IRMS). At present only L-glutamic acids USGS40 and USGS41 satisfy these requirements for ??13C and ??13N, with the limitation that L-glutamic acid is not suitable for analysis by gas chromatography (GC). We describe the development and quality testing of (i) four nicotine laboratory reference materials for on-line (i.e. continuous flow) hydrogen reductive gas chromatography-isotope ratio mass-spectrometry (GC-IRMS), (ii) five nicotines for oxidative C, N gas chromatography-combustion-isotope ratio mass-spectrometry (GC-C-IRMS, or GC-IRMS), and (iii) also three acetanilide and three urea reference materials for on-line oxidative EA-IRMS for C and N. Isotopic off-line calibration against international stable isotope measurement standards at Indiana University adhered to the 'principle of identical treatment'. The new reference materials cover the following isotopic ranges: ??2Hnicotine -162 to -45%o, ??13Cnicotine -30.05 to +7.72%, ?? 15Nnicotine -6.03 to +33.62%; ??15N acetanilide +1-18 to +40.57%; ??13Curea -34.13 to +11.71%, ??15Nurea +0.26 to +40.61% (recommended ?? values refer to calibration with NBS 19, L-SVEC, IAEA-N-1, and IAEA-N-2). Nicotines fill a gap as the first organic nitrogen stable isotope reference materials for GC-IRMS that are available with different ??13N values. Comparative ??13C and ??15N on-line EA-IRMS data from 14 volunteering laboratories document the usefulness and reliability of acetanilides and ureas as EA-IRMS reference materials.

  1. Thermographic and clinical correlation of myofascial trigger points in the masticatory muscles

    PubMed Central

    Haddad, D S; Brioschi, M L; Arita, E S

    2012-01-01

    Objectives The aim of the study was to identify and correlate myofascial trigger points (MTPs) in the masticatory muscles, using thermography and algometry. Methods 26 female volunteers were recruited. The surface facial area over the masseter and anterior temporalis muscles was divided into 15 subareas on each side (n = 780). This investigation consisted of three steps. The first step involved thermographic facial examination, using lateral views. The second step involved the pressure pain threshold (PPT), marking the MTP pattern areas for referred pain (n = 131) and local pain (n = 282) with a coloured pencil, and a photograph of the lateral face with the head in the same position as the infrared imaging. The last step was the fusion of these two images, using dedicated software (Reporter® 8.5—SP3 Professional Edition and QuickReport® 1.2, FLIR Systems, Wilsonville, OR); and the calculation of the temperature of each point. Results PPT levels measured at the points of referred pain in MTPs (1.28 ± 0.45 kgf) were significantly lower than the points of local pain in MTPs (1.73 ± 0.59 kgf; p < 0.05). Infrared imaging indicated differences between referred and local pain in MTPs of 0.5 °C (p < 0.05). Analysis of the correlation between the PPT and infrared imaging was done using the Spearman non-parametric method, in which the correlations were positive and moderate (0.4 ≤ r < 0.7). The sensitivity and specificity in MTPs were 62.5% and 71.3%, respectively, for referred pain, and 43.6% and 60.6%, respectively, for local pain. Conclusion Infrared imaging measurements can provide a useful, non-invasive and non-ionizing examination for diagnosis of MTPs in masticatory muscles. PMID:23166359

  2. Biodiversity of rocky intertidal benthic communities associated with copper mine tailing discharges in northern Chile.

    PubMed

    Medina, M; Andrade, S; Faugeron, S; Lagos, N; Mella, D; Correa, J A

    2005-04-01

    Copper mine tailings have been discharged around the city of Chanaral, in northern Chile, for more than 60 years. This report summarizes a 17-month long monitoring study of species richness and biodiversity at five intertidal sites around the point of the tailing discharge. Total dissolved copper in sites close to the point of discharge varied between 8.72 microg/l and 34.15 microg/l, showing that there has not been a significant reduction since 1994. However, species richness has increased, suggesting a possible recovery of the system. While diversity of sessile organisms correlates negatively with dissolved copper, diversity of mobile invertebrates did not correlate with the metal concentration. To explain the observed results we discuss the role of algal turf interference on the distribution of mobile invertebrates at reference sites, a top-down effect caused by the absence of carnivores at impacted sites, and an avoidance strategy by some species to reduce their contact with contaminated seawater.

  3. Assessment of blood lead level declines in an area of historical mining with a holistic remediation and abatement program.

    PubMed

    Schoof, Rosalind A; Johnson, Dina L; Handziuk, Emma R; Landingham, Cynthia Van; Feldpausch, Alma M; Gallagher, Alexa E; Dell, Linda D; Kephart, Amy

    2016-10-01

    Lead exposure and blood lead levels (BLLs) in the United States have declined dramatically since the 1970s as many widespread lead uses have been discontinued. Large scale mining and mineral processing represents an additional localized source of potential lead exposure in many historical mining communities, such as Butte, Montana. After 25 years of ongoing remediation efforts and a residential metals abatement program that includes blood lead monitoring of Butte children, examination of blood lead trends offers a unique opportunity to assess the effectiveness of Butte's lead source and exposure reduction measures. This study examined BLL trends in Butte children ages 1-5 (n= 2796) from 2003-2010 as compared to a reference dataset matched for similar demographic characteristics over the same period. Blood lead differences across Butte during the same period are also examined. Findings are interpreted with respect to effectiveness of remediation and other factors potentially contributing to ongoing exposure concerns. BLLs from Butte were compared with a reference dataset (n=2937) derived from the National Health and Nutrition Examination Survey. The reference dataset was initially matched for child age and sample dates. Additional demographic factors associated with higher BLLs were then evaluated. Weights were applied to make the reference dataset more consistent with the Butte dataset for the three factors that were most disparate (poverty-to-income ratio, house age, and race/ethnicity). A weighted linear mixed regression model showed Butte geometric mean BLLs were higher than reference BLLs for 2003-2004 (3.48vs. 2.05µg/dL), 2005-2006 (2.65vs. 1.80µg/dL), and 2007-2008 (2.2vs. 1.72µg/dL), but comparable for 2009-2010 (1.53vs. 1.51µg/dL). This trend suggests that, over time, the impact of other factors that may be associated with Butte BLLs has been reduced. Neighborhood differences were examined by dividing the Butte dataset into the older area called "Uptown", located at higher elevation atop historical mine workings, and "the Flats", at lower elevation and more recently developed. Significant declines in BLLs were observed over time in both areas, though Uptown had slightly higher BLLs than the Flats (2003-2004: 3.57vs. 3.45µg/dL, p=0.7; 2005-2006: 2.84vs. 2.52µg/dL, p=0.1; 2007-2008: 2.58vs. 1.99µg/dL, p=0.001; 2009-2010: 1.71vs. 1.44µg/dL, p=0.02). BLLs were higher when tested in summer/fall than in winter/spring for both neighborhoods, and statistically higher BLLs were found for children in Uptown living in properties built before 1940. Neighborhood differences and the persistence of a greater percentage of high BLLs (>5µg/dL) in Butte vs. the reference dataset support continuation of the home lead abatement program. Butte BLL declines likely reflect the cumulative effectiveness of screening efforts, community-wide remediation, and the ongoing metals abatement program in Butte in addition to other factors not accounted for by this study. As evidenced in Butte, abatement programs that include home evaluations and assistance in addressing multiple sources of lead exposure can be an important complement to community-wide soil remediation activities. Copyright © 2015 The Authors. Published by Elsevier Inc. All rights reserved.

  4. Value of high-sensitivity C-reactive protein assays in predicting atrial fibrillation recurrence: a systematic review and meta-analysis.

    PubMed

    Yo, Chia-Hung; Lee, Si-Huei; Chang, Shy-Shin; Lee, Matthew Chien-Hung; Lee, Chien-Chang

    2014-02-20

    We performed a systematic review and meta-analysis of studies on high-sensitivity C-reactive protein (hs-CRP) assays to see whether these tests are predictive of atrial fibrillation (AF) recurrence after cardioversion. Systematic review and meta-analysis. PubMed, EMBASE and Cochrane databases as well as a hand search of the reference lists in the retrieved articles from inception to December 2013. This review selected observational studies in which the measurements of serum CRP were used to predict AF recurrence. An hs-CRP assay was defined as any CRP test capable of measuring serum CRP to below 0.6 mg/dL. We summarised test performance characteristics with the use of forest plots, hierarchical summary receiver operating characteristic curves and bivariate random effects models. Meta-regression analysis was performed to explore the source of heterogeneity. We included nine qualifying studies comprising a total of 347 patients with AF recurrence and 335 controls. A CRP level higher than the optimal cut-off point was an independent predictor of AF recurrence after cardioversion (summary adjusted OR: 3.33; 95% CI 2.10 to 5.28). The estimated pooled sensitivity and specificity for hs-CRP was 71.0% (95% CI 63% to 78%) and 72.0% (61% to 81%), respectively. Most studies used a CRP cut-off point of 1.9 mg/L to predict long-term AF recurrence (77% sensitivity, 65% specificity), and 3 mg/L to predict short-term AF recurrence (73% sensitivity, 71% specificity). hs-CRP assays are moderately accurate in predicting AF recurrence after successful cardioversion.

  5. Distribution and speciation of mercury affected by humic acid in mariculture sites at the Pearl River estuary.

    PubMed

    Ding, Lingyun; Zhao, Kaiyun; Zhang, Lijuan; Liang, Peng; Wu, Shengchun; Wong, Ming Hung; Tao, Huchun

    2018-05-14

    At the Pearl River Estuary of southern China, mercury and its environmental problems have long been a great concern. This study investigated the distribution and speciation of mercury compounds that are significantly influenced by the increasing content of humic acid (HA, a model natural organic matter) in this region. The inorganic mercury and methyl mercury, being adsorbed and converted at different HA levels, were studied in sediments and surface water at both mariculture and their reference sites. In mariculture sediments with higher HA content (up to 4.5%), more mercury were adsorbed at different compound levels, promoting the methylation and accumulation of mercury (P < 0.05) at the sediment-water interface. Seasonal shift in environmental temperature might control the HA content, subsequently favouring mercury methylation (maximum 1.75 ± 0.08 mg L -1 d -1 ) under warm weather conditions. In reference sites received less HA wastes, lower adsorption capacity and methylation rate were observed for mercury in sediments and surface water. Our work points to the significant roles of HA on mercury distribution and speciation both spatially and seasonally, thus addressing the impacts of mariculture activities on estuary eco-system. Copyright © 2018 Elsevier Ltd. All rights reserved.

  6. European and Mexican vs US diagnostic extracts of Bermuda grass and cat in skin testing.

    PubMed

    Larenas-Linnemann, Désirée; Cruz, Alfredo Arias; Gutierrez, Isabel Rojo; Rodriguez, Pablo; Shah-Hosseini, Kijawasch; Michels, Alexandra; Mösges, Ralph

    2011-05-01

    Laboratory testing of various diagnostic extracts has shown lower potencies for several European and Mexican extracts relative to the US Food and Drug Administration (FDA) reference (10,000 BAU/mL). Quantitative skin prick testing (QSPT) with Dermatophagoides pteronyssinus extracts have previously shown a similar picture. To compare European and Mexican Bermuda grass (BG) and cat diagnostic extracts against an FDA-validated extract using QSPT. Six diagnostic BG and cat extracts (1 reference FDA extract, 3 European extracts, 1 imported nonstandardized extract from the United States, and 1 Mexican extract) were tested with quadruplicate QSPT, as a concentrate and as 2 serial 2-fold dilutions, in cat and BG allergic individuals. BG showed good dose response in wheal size for the concentrate (1:2-1:4 dilutions; steep part of the curve). Cat showed poorer dose response. The Wilcoxon test for linked random samples was used to investigate whether the distribution of the reference differed from each of the test extracts to a statistically significant degree (2-sided asymptotic significance, α = .05). All BG and 2 cat extracts were statistically less potent than the 10,000 BAU/mL US reference. European BG extracts were 7,700, 4,100, and 1,600 BAU/mL, and cat extracts were 12,500, 4,400, and 5,100 BAU/mL. The potency of some diagnostic extracts of BG and cat used in Europe, Mexico, and the United States differs, with the US extracts being generally more potent. On the basis of provocation tests, optimal diagnostic concentrations should be determined. Similar comparisons using other manufacturers and therapeutic extracts might be interesting. Copyright © 2011 American College of Allergy, Asthma & Immunology. Published by Elsevier Inc. All rights reserved.

  7. PD-L1 expression according to the EGFR status in primary lung adenocarcinoma.

    PubMed

    Takada, Kazuki; Toyokawa, Gouji; Tagawa, Tetsuzo; Kohashi, Kenichi; Shimokawa, Mototsugu; Akamine, Takaki; Takamori, Shinkichi; Hirai, Fumihiko; Shoji, Fumihiro; Okamoto, Tatsuro; Oda, Yoshinao; Maehara, Yoshihiko

    2018-02-01

    It was reported that programmed cell death-ligand 1 (PD-L1) expression is associated with smoking and wild-type epidermal growth factor receptor (EGFR) in lung adenocarcinoma. However, the association between PD-L1 expression and EGFR mutation site in EGFR mutation-positive lung adenocarcinoma is unclear. We retrospectively examined the relationship between PD-L1 expression and EGFR status in 441 surgically resected primary lung adenocarcinomas. Membrane PD-L1 expression on tumor cells was evaluated by immunohistochemical analysis using a PD-L1 antibody (clone SP142) and defined by tumor proportion scores (TPSs) of 0%, 1-4%, 5-49%, and ≥50%, respectively. Two hundred and eighteen (49.4%) patients had wild-type EGFR, and 223 (50.6%) had mutant EGFR-98 (44.0%) with exon 19 deletion, 116 (52.0%) with exon 21 L858R point mutation, and nine (4.0%) with another EGFR mutation. Overall, Fisher's exact test showed that PD-L1 positivity was associated with wild-type EGFR, and there was only one case with PD-L1 TPS ≥50% among the cases with mutant EGFR. The analysis of cases with mutant EGFR indicated no significant association between EGFR mutation site and PD-L1 expression. However, the prevalence of PD-L1 TPS 5-49% was higher among patients with EGFR exon 19 deletion than with EGFR exon 21 L858R point mutation. PD-L1 expression was significantly associated with wild-type EGFR, and PD-L1 TPS ≥50% seldom overlaps with presence of driver oncogene EGFR. There was no significant difference in PD-L1 expression among the EGFR mutation sites. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Declining blood lead levels and cognitive changes in moderately lead-poisoned children.

    PubMed

    Ruff, H A; Bijur, P E; Markowitz, M; Ma, Y C; Rosen, J F

    1993-04-07

    To determine whether chelation therapy or biochemical changes during a lead-lowering intervention was associated with changes in cognitive functioning of moderately lead-poisoned children. It was hypothesized that cognitive performance would improve as blood lead level declined over time. Short-term intervention study with measures obtained before and after intervention. Hospital specialty clinic and university research center. A total of 154 previously untreated children referred to clinic with blood lead levels between 1.21 and 2.66 mumol/L (25 and 55 micrograms/dL) at time of enrollment. Ages ranged from 13 to 87 months. Enrolled children were treated with edetate calcium disodium (EDTA) if eligible and/or with orally administered iron supplement if iron deficient. For all children, housing inspections and abatement procedures were performed as necessary. Score on Bayley Mental Development Scale or Stanford-Binet Intelligence Scale (4th edition). There was no effect of edetate calcium disodium treatment per se. In the short term (7 weeks), changes in blood lead levels were not related to changes in cognitive scores. In the long term (6 months), however, changes in performance were significantly related to changes in blood lead level, even after controlling for confounding variables. The standardized score increased 1 point for every decrease of 0.14 mumol/L (3 micrograms/dL) in blood lead level. The results suggest an association between decreases in blood lead level and cognitive improvements in moderately lead-poisoned children.

  9. Genetics Home Reference: Björnstad syndrome

    MedlinePlus

    ... species, which are harmful molecules that can damage DNA and tissues. BCS1L gene mutations involved in Björnstad syndrome alter the BCS1L protein and impair its ability to aid in complex III formation. The resulting decrease in complex III activity reduces ...

  10. Establishing reference intervals for electrolytes in newborns and infants using direct ISE analyzer

    PubMed Central

    2013-01-01

    Background To generate clinically applicable reference intervals (RIs) for commonly requested electrolytes in Ethiopian newborns and infants that can help in early detection, close monitoring and correction of electrolyte abnormalities. Cord blood (from newborns, n = 60) and venous blood samples (from infants, n = 57) were collected and analyzed using direct ISE analyzer, AVL (9181). MedCalc® software was applied to determine the robust upper and lower end points covering 95% of the reference values of each electrolyte with respective 90% CIs. Findings This is an extension report of our recent study; and hence is resulted from the same data source. The level of Na+ and K+ showed difference in newborns and infants even though combined RIs were suggested by the Haris and Boyd rule as 126–143 mmol/l and 4.0-7.9 mmol/l respectively. However, Cl- values failed to show such a difference and thus a combined RI was determined to be 100–111 mmol/l. Almost all maternal, neonatal and infantile factors were not able to affect the values of the electrolytes. Conclusion Combined RIs are suggested for the interpretation of electrolyte values in newborns and infants without taking the effect of maternal, neonatal and infantile factors into account. Since the RIs were different from previously reported values, it will be appropriate to apply such RIs for the interpretation of electrolyte values in Ethiopian pediatric population. PMID:23688032

  11. Characterisation of a highly sensitive troponin I assay and its application to a cardio-healthy population.

    PubMed

    Koerbin, Gus; Tate, Jill; Potter, Julia M; Cavanaugh, Juleen; Glasgow, Nicholas; Hickman, Peter E

    2012-02-03

    Abbott Diagnostics have developed a new highly sensitive troponin I (hs-TnI) assay. We have assessed its analytical characteristics and applied the assay to a population of apparently cardio-healthy persons. We assessed imprecision, bias compared to the previous generation assay, matrix effects, and interferences and applied the assay to an apparently healthy population, deriving the 99th percentile limit of the distribution of values in reference populations for men and women separately. The dynamic range of the assay was ranged from 0.5-50,000 ng/L (pg/mL). The 10% CV was at a concentration of 3.9 ng/L, and the 20% CV was at a concentration of 1.8 ng/L. The new and current version of the TnI assay were highly correlated [slope: 0.98 (95%CI:0.88-1.07), y-intercept:1.20 (95%CI:-2.35-4.75) r²=0.99]. The 99th percentile limit of the distribution of values in a reference population was different for males and females: for males 14.0 ng/L and for females 11.1 ng/L and at these concentrations the assay CV was 5.0%. TnI was detectable in nearly all patient samples from the healthy reference population (98.6%). This new hs-TnI assay is able to measure to an order of magnitude lower than the current generation TnI assay from the same manufacturer. With TnI being detectable in nearly all apparently healthy subject samples this suggests that TnI presence does not always indicate cardiomyocyte necrosis.

  12. Cloud point extraction and diffuse reflectance-Fourier transform infrared spectroscopic determination of chromium(VI): A probe to adulteration in food stuffs.

    PubMed

    Tiwari, Swapnil; Deb, Manas Kanti; Sen, Bhupendra K

    2017-04-15

    A new cloud point extraction (CPE) method for the determination of hexavalent chromium i.e. Cr(VI) in food samples is established with subsequent diffuse reflectance-Fourier transform infrared (DRS-FTIR) analysis. The method demonstrates enrichment of Cr(VI) after its complexation with 1,5-diphenylcarbazide. The reddish-violet complex formed showed λ max at 540nm. Micellar phase separation at cloud point temperature of non-ionic surfactant, Triton X-100 occurred and complex was entrapped in surfactant and analyzed using DRS-FTIR. Under optimized conditions, the limit of detection (LOD) and quantification (LOQ) were 1.22 and 4.02μgmL -1 , respectively. Excellent linearity with correlation coefficient value of 0.94 was found for the concentration range of 1-100μgmL -1 . At 10μgmL -1 the standard deviation for 7 replicate measurements was found to be 0.11μgmL -1 . The method was successfully applied to commercially marketed food stuffs, and good recoveries (81-112%) were obtained by spiking the real samples. Copyright © 2016 Elsevier Ltd. All rights reserved.

  13. Here, There, and Everywhere: Reference at the Point-of-Need.

    ERIC Educational Resources Information Center

    Trump, Judith F.; Tuttle, Ian P.

    2001-01-01

    Growing numbers of libraries are experimenting with a new form of interactive reference to extend service to their patrons at the point-of-need and time-of-need. Examines digital reference for the altered user culture and point-of-need service products. Describes a pilot project offering chat reference service. Discuses developing service…

  14. Robust method to detect and locate local earthquakes by means of amplitude measurements.

    NASA Astrophysics Data System (ADS)

    del Puy Papí Isaba, María; Brückl, Ewald

    2016-04-01

    In this study we present a robust new method to detect and locate medium and low magnitude local earthquakes. This method is based on an empirical model of the ground motion obtained from amplitude data of earthquakes in the area of interest, which were located using traditional methods. The first step of our method is the computation of maximum resultant ground velocities in sliding time windows covering the whole period of interest. In the second step, these maximum resultant ground velocities are back-projected to every point of a grid covering the whole area of interest while applying the empirical amplitude - distance relations. We refer to these back-projected ground velocities as pseudo-magnitudes. The number of operating seismic stations in the local network equals the number of pseudo-magnitudes at each grid-point. Our method introduces the new idea of selecting the minimum pseudo-magnitude at each grid-point for further analysis instead of searching for a minimum of the L2 or L1 norm. In case no detectable earthquake occurred, the spatial distribution of the minimum pseudo-magnitudes constrains the magnitude of weak earthquakes hidden in the ambient noise. In the case of a detectable local earthquake, the spatial distribution of the minimum pseudo-magnitudes shows a significant maximum at the grid-point nearest to the actual epicenter. The application of our method is restricted to the area confined by the convex hull of the seismic station network. Additionally, one must ensure that there are no dead traces involved in the processing. Compared to methods based on L2 and even L1 norms, our new method is almost wholly insensitive to outliers (data from locally disturbed seismic stations). A further advantage is the fast determination of the epicenter and magnitude of a seismic event located within a seismic network. This is possible due to the method of obtaining and storing a back-projected matrix, independent of the registered amplitude, for each seismic station. As a direct consequence, we are able to save computing time for the calculation of the final back-projected maximum resultant amplitude at every grid-point. The capability of the method was demonstrated firstly using synthetic data. In the next step, this method was applied to data of 43 local earthquakes of low and medium magnitude (1.7 < magnitude scale < 4.3). These earthquakes were recorded and detected by the seismic network ALPAACT (seismological and geodetic monitoring of Alpine PAnnonian ACtive Tectonics) in the period 2010/06/11 to 2013/09/20. Data provided by the ALPAACT network is used in order to understand seismic activity in the Mürz Valley - Semmering - Vienna Basin transfer fault system in Austria and what makes it such a relatively high earthquake hazard and risk area. The method will substantially support our efforts to involve scholars from polytechnic schools in seismological work within the Sparkling Science project Schools & Quakes.

  15. Four distinct immune microenvironment subtypes in gastric adenocarcinoma with special reference to microsatellite instability

    PubMed Central

    Heo, You Jeong; Kim, Seungtae; Kim, Nayoung KD; Park, Joon Oh; Kang, Won Ki; Lee, Jeeyun; Kim, Kyoung-Mee

    2018-01-01

    Introduction Programmed death-ligand 1 (PD-L1) can be overexpressed in tumours other than Epstein-Barr virus (EBV)-positive (EBV+) or microsatellite instability-high (MSI-H) gastric cancer (GC) subtypes. We aimed to determine the tumour immune microenvironment (TME) classification of GC to better understand tumour–immune interactions and help patient selection for future immunotherapy with special reference to MSI-H. Methods Immunohistochemistry (IHC) for PD-L1 and CD8+ T cells in three distinct subtypes of GC (43 EBV+, 79 MSI-H and 125 EBV−/MSS) were performed and analysed. In 66 MSI-H GC, mutation counts were compared with PD-L1 expression and survival of the patients. Results GC TME divided by PD-L1 IHC and tumour-infiltrating lymphocytes (TIL) measured by intratumoural CD8 density showed: (1) about 40% of GC are type I (PD-L1+/TIL+) consisting ~70% of MSI-H or EBV+ GC, and ~15% of EBV−/microsatellite stable (MSS) GC patients show the best survival in both disease-free (HR 2.044) and overall survival (HR 1.993); this type would respond to a checkpoint blockade therapy; (2) almost 30% of GC are type II (PD-L1−/TIL−) with the worst survival; (3) approximately 10% of GC are type III (PD-L1+/TIL−); and (4) up to 20% are type IV (PD-L1−/TIL+) and, unexpectedly, ~25% of EBV+ or MSI-H GC are within this subtype. In MSI-H GC, frequent frameshift mutations were observed in ARID1A, RNF43, NF1, MSH6, BRD3, NCOA3, BCORL1, TNKS2 and NPM1 and the numbers of frameshift mutation correlated significantly with PD-L1 expression (P<0.05). Discussion GC can be classified into four TME types based on PD-L1 and TIL, and numbers of frameshift mutation correlate well with PD-L1 expression in MSI-H GC. PMID:29636988

  16. Four distinct immune microenvironment subtypes in gastric adenocarcinoma with special reference to microsatellite instability.

    PubMed

    Cho, Junhun; Chang, Young Hwan; Heo, You Jeong; Kim, Seungtae; Kim, Nayoung Kd; Park, Joon Oh; Kang, Won Ki; Lee, Jeeyun; Kim, Kyoung-Mee

    2018-01-01

    Programmed death-ligand 1 (PD-L1) can be overexpressed in tumours other than Epstein-Barr virus (EBV)-positive (EBV + ) or microsatellite instability-high (MSI-H) gastric cancer (GC) subtypes. We aimed to determine the tumour immune microenvironment (TME) classification of GC to better understand tumour-immune interactions and help patient selection for future immunotherapy with special reference to MSI-H. Immunohistochemistry (IHC) for PD-L1 and CD8 + T cells in three distinct subtypes of GC (43 EBV + , 79 MSI-H and 125 EBV - /MSS) were performed and analysed. In 66 MSI-H GC, mutation counts were compared with PD-L1 expression and survival of the patients. GC TME divided by PD-L1 IHC and tumour-infiltrating lymphocytes (TIL) measured by intratumoural CD8 density showed: (1) about 40% of GC are type I (PD-L1 + /TIL + ) consisting ~70% of MSI-H or EBV + GC, and ~15% of EBV - /microsatellite stable (MSS) GC patients show the best survival in both disease-free (HR 2.044) and overall survival (HR 1.993); this type would respond to a checkpoint blockade therapy; (2) almost 30% of GC are type II (PD-L1 - /TIL - ) with the worst survival; (3) approximately 10% of GC are type III (PD-L1 + /TIL - ); and (4) up to 20% are type IV (PD-L1 - /TIL + ) and, unexpectedly, ~25% of EBV + or MSI-H GC are within this subtype. In MSI-H GC, frequent frameshift mutations were observed in ARID1A , RNF43 , NF1 , MSH6 , BRD3 , NCOA3 , BCORL1 , TNKS2 and NPM1 and the numbers of frameshift mutation correlated significantly with PD-L1 expression (P<0.05). GC can be classified into four TME types based on PD-L1 and TIL, and numbers of frameshift mutation correlate well with PD-L1 expression in MSI-H GC.

  17. 49 CFR 195.207 - Transportation of pipe.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... in accordance with API Recommended Practice 5L1 (incorporated by reference, see § 195.3). (b) Ship or... with API Recommended Practice 5LW (incorporated by reference, see § 195.3). [ Amdt. 195-94, 75 FR 48606...

  18. 49 CFR 195.207 - Transportation of pipe.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... in accordance with API Recommended Practice 5L1 (incorporated by reference, see § 195.3). (b) Ship or... with API Recommended Practice 5LW (incorporated by reference, see § 195.3). [ Amdt. 195-94, 75 FR 48606...

  19. The Development and Study of Molecular Electronic Switches and their Field-Effect Transistor (FET) Device Properties

    DTIC Science & Technology

    2015-02-27

    Grand Rapids, MI) meetings and conferences. References 1. L.N Lucas, J.J.D. de Jong, J.H. van Esch, R.M. Kellogg , B.L. Berringa. Eur. J. Org...R.M. Kellogg , H.L. Feringa, H.L. Eur. J. Org. Chem., 2003, 155-166. 6. B. Qin, R. Yao, X. Zhao, H. Tian. Org. Biomol. Chem., 1, 2003, 2187-2191...7. L.N. Lucas, J.H. van Euch, R.M. Kellogg , B. Feringa. Chem. Comm., 1998, 2313-2314.

  20. Assessment of probabilistic areal reduction factors of precipitations for the entire French territory with gridded rainfall data.

    NASA Astrophysics Data System (ADS)

    Fouchier, Catherine; Maire, Alexis; Arnaud, Patrick; Cantet, Philippe; Odry, Jean

    2016-04-01

    The starting point of our study was the availability of maps of rainfall quantiles available for the entire French mainland territory at the spatial resolution of 1 km². These maps display the rainfall amounts estimated for different rainfall durations (from 15 minutes to 72 hours) and different return periods (from 2 years up to 1 000 years). They are provided by a regionalized stochastic hourly point rainfall generator, the SHYREG method which was previously developed by Irstea (Arnaud et al., 2007; Cantet and Arnaud, 2014). Being calibrated independently on numerous raingauges data (with an average density across the country of 1 raingauge per 200 km²), this method suffers from a limitation common to point-process rainfall generators: it can only reproduce point rainfall patterns and has no capacity to generate rainfall fields. It can't hence provide areal rainfall quantiles, the estimation of the latter being however needed for the construction of design rainfall or for the diagnostic of observed events. One means of bridging this gap between our local rainfall quantiles and areal rainfall quantiles is given by the concept of probabilistic areal reduction factors of rainfall (ARF) as defined by Omolayo (1993). This concept enables to estimate areal rainfall of a particular frequency within a certain amount of time from point rainfalls of the same frequency and duration. Assessing such ARF for the whole French territory is of particular interest since it should allow us to compute areal rainfall quantiles, and eventually watershed rainfall quantiles, by using the already available grids of statistical point rainfall of the SHYREG method. Our purpose was then to assess these ARF thanks to long time-series of spatial rainfall data. We have used two sets of rainfall fields: i) hourly rainfall fields from a 10-year reference database of Quantitative Precipitation Estimation (QPE) over France (Tabary et al., 2012), ii) daily rainfall fields resulting from a 53-year high-resolution atmospheric reanalysis over France with the SAFRAN-gauge-based analysis system (Vidal et al., 2010). We have then built samples of maximal rainfalls for each cell location (the "point" rainfalls) and for different areas centered on each cell location (the areal rainfalls) of these gridded data. To compute rainfall quantiles, we have fitted a Gumbel law, with the L-moment method, on each of these samples. Our daily and hourly ARF have then shown four main trends: i) a sensitivity to the return period, with ARF values decreasing when the return period increases; ii) a sensitivity to the rainfall duration, with ARF values decreasing when the rainfall duration decreases; iii) a sensitivity to the season, with ARF values smaller for the summer period than for the winter period; iv) a sensitivity to the geographical location, with low ARF values in the French Mediterranean area and ARF values close to 1 for the climatic zones of Northern and Western France (oceanic to semi-continental climate). The results of this data-intensive study led for the first time on the whole French territory are in agreement with studies led abroad (e.g. Allen and DeGaetano 2005, Overeem et al. 2010) and confirm and widen the results of previous studies that were carried out in France on smaller areas and with fewer rainfall durations (e.g. Ramos et al., 2006, Neppel et al., 2003). References Allen R. J. and DeGaetano A. T. (2005). Areal reduction factors for two eastern United States regions with high rain-gauge density. Journal of Hydrologic Engineering 10(4): 327-335. Arnaud P., Fine J.-A. and Lavabre J. (2007). An hourly rainfall generation model applicable to all types of climate. Atmospheric Research 85(2): 230-242. Cantet, P. and Arnaud, P. (2014). Extreme rainfall analysis by a stochastic model: impact of the copula choice on the sub-daily rainfall generation, Stochastic Environmental Research and Risk Assessment, Springer Berlin Heidelberg, 28(6), 1479-1492. Neppel L., Bouvier C. and Lavabre J. (2003). Areal reduction factor probabilities for rainfall in Languedoc Roussillon. IAHS-AISH Publication (278): 276-283. Omolayo, A. S. (1993). On the transposition of areal reduction factors for rainfall frequency estimation. Journal of Hydrology 145 (1-2): 191-205. Overeem A., Buishand T. A., Holleman I. and Uijlenhoet R. (2010). Extreme value modeling of areal rainfall from weather radar. Water Resources Research 46(9): 10 p. Ramos M.-H., Leblois E., Creutin J.-D. (2006). From point to areal rainfall: Linking the different approaches for the frequency characterisation of rainfalls in urban areas. Water Science and Technology. 54(6-7): 33-40. Tabary P., Dupuy P., L'Henaff G., Gueguen C., Moulin L., Laurantin O., Merlier C., Soubeyroux J. M. (2012). A 10-year (1997-2006) reanalysis of Quantitative Precipitation Estimation over France: methodology and first results. IAHS-AISH Publication (351) : 255-260. Vidal J.-P., Martin E., Franchistéguy L., Baillon M. and Soubeyroux J.-M. (2010). A 50-year high-resolution atmospheric reanalysis over France with the Safran system. International Journal of Climatology 30(11): 1627-1644.

  1. Time to health-related quality of life score deterioration as a modality of longitudinal analysis for health-related quality of life studies in oncology: do we need RECIST for quality of life to achieve standardization?

    PubMed

    Anota, Amélie; Hamidou, Zeinab; Paget-Bailly, Sophie; Chibaudel, Benoist; Bascoul-Mollevi, Caroline; Auquier, Pascal; Westeel, Virginie; Fiteni, Frederic; Borg, Christophe; Bonnetain, Franck

    2015-01-01

    Longitudinal analysis of health-related quality of life (HRQoL) remains unstandardized and compromises comparison of results between trials. In oncology, despite available statistical approaches, results are poorly used to change standards of care, mainly due to lack of standardization and the ability to propose clinical meaningful results. In this context, the time to deterioration (TTD) has been proposed as a modality of longitudinal HRQoL analysis for cancer patients. As for tumor response and progression, we propose to develop RECIST criteria for HRQoL. Several definitions of TTD are investigated in this paper. We applied this approach in early breast cancer and metastatic pancreatic cancer with a 5-point minimal clinically important difference. In breast cancer, TTD was defined as compared to the baseline score or to the best previous score. In pancreatic cancer (arm 1: gemcitabine with FOLFIRI.3, arm 2: gemcitabine alone), the time until definitive deterioration (TUDD) was investigated with or without death as event. In the breast cancer study, 381 women were included. The median TTD was influenced by the choice of the reference score. In pancreatic cancer study, 98 patients were enrolled. Patients in Arm 1 presented longer TUDD than those in Arm 2 for most of HRQoL scores. Results of TUDD were slightly different according to the definition of deterioration applied. Currently, the international ARCAD group supports the idea of developing RECIST for HRQoL in pancreatic and colorectal cancer with liver metastasis, with a view to using HRQoL as a co-primary endpoint along with a tumor parameter.

  2. Biological Variability in Serum Cortisol Concentration Post-adrenocorticotropic Hormone Stimulation in Healthy Dogs.

    PubMed

    Gal, A; Weidgraaf, K; Bowden, J P; Lopez-Villalobos, N; Cave, N J; Chambers, J P; Castillo-Alcala, F

    2017-05-01

    The ACTH stimulation has low sensitivity for the diagnosis of hypercortisolism possibly as a result of biological and analytical variability. To report the components of biological and analytical variability in serum cortisol concentration post-ACTH stimulation ([cortisol]) in healthy dogs. Fourteen healthy harrier hound dogs. The data were extracted from a separate, prospective, randomized, double-blinded, controlled discovery study in which dogs treated with vehicle control and 4 different doses of cortisone acetate (CA) for 7 days had an ACTH stimulation test performed to confirm the dose-dependent effect of CA. The index of individuality (IoI), the critical difference between sequential measurements (C D ), and the number of measurements required to assess the homeostatic set point (HSP) of [cortisol] with confidence intervals (CI) of 90 and 95% were estimated. The IoI was equal to 1.1 and the C D was 3.3 μg/dL (92 nmol/L). The number of measurements required to assess the HSP of [cortisol] with CI of 90 and 95% were 3 and 15, respectively. Additionally, mean [cortisol] was higher in males than in females (13.3 ± 4 μg/dL [366 ± 114 nmol/L] vs. 11.5 ± 2.5 μg/dL [318 ± 65 nmol/L], respectively; P = .046). As expected, treatment with CA resulted in a dose-dependent suppression of [cortisol]. False-negative test results in hypercortisolism could occur when [cortisol] is outside of the individual's HSP and within the reference interval. The large C D emphasizes the importance of assessing clinically relevant parameters in the diagnosis and monitoring of HC. Copyright © 2017 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine.

  3. Bay of Fundy verification of a system for multidate Landsat measurement of suspended sediment

    NASA Technical Reports Server (NTRS)

    Munday, J. C., Jr.; Afoldi, T. T.; Amos, C. L.

    1981-01-01

    A system for automated multidate Landsat CCT MSS measurement of suspended sediment concentration (S) has been implemented and verified on nine sets (108 points) of data from the Bay of Fundy, Canada. The system employs 'chromaticity analysis' to provide automatic pixel-by-pixel adjustment of atmospheric variations, permitting reference calibration data from one or several dates to be spatially and temporally extrapolated to other regions and to other dates. For verification, each data set was used in turn as test data against the remainder as a calibration set: the average absolute error was 44 percent of S over the range 1-1000 mg/l. The system can be used to measure chlorophyll (in the absence of atmospheric variations), Secchi disk depth, and turbidity.

  4. Application of asymmetric flow field-flow fractionation (AsFlFFF) coupled to inductively coupled plasma mass spectrometry (ICPMS) to the quantitative characterization of natural colloids and synthetic nanoparticles.

    PubMed

    Bouby, M; Geckeis, H; Geyer, F W

    2008-12-01

    A straightforward quantification method is presented for the application of asymmetric flow field-flow fractionation (AsFlFFF) combined with inductively coupled plasma mass spectrometry (ICPMS) to the characterization of colloid-borne metal ions and nanoparticles. Reproducibility of the size calibration and recovery of elements are examined. Channel flow fluctuations are observed notably after initiation of the fractionation procedure. Their impact on quantification is considered by using (103)Rh as internal reference. Intensity ratios measured for various elements and Rh are calculated for each data point. These ratios turned out to be independent of the metal concentration and total sample solution flow introduced into the nebulizer within a range of 0.4-1.2 mL min(-1). The method is applied to study the interaction of Eu, U(VI) and Th with a mixture of humic acid and clay colloids and to the characterization of synthetic nanoparticles, namely CdSe/ZnS-MAA (mercaptoacetic acid) core/shell-coated quantum dots (QDs). Information is given not only on inorganic element composition but also on the effective hydrodynamic size under relevant conditions. Detection limits (DLs) are estimated for Ca, Al, Fe, the lanthanide Ce and the natural actinides Th and U in colloid-containing groundwater. For standard crossflow nebulizer, estimated values are 7 x 10(3), 20, 3 x 10(2), 0.1, 0.1 and 7 x 10(-2) microg L(-1), respectively. DLs for Zn and Cd in QD characterization are 28 and 11 microg L(-1), respectively.

  5. E&V (Evaluation and Validation) Reference Manual, Version 1.0.

    DTIC Science & Technology

    1988-07-01

    references featured in the Reference Manual. G-05097a GENERAL REFERENCE INFORMATION EXTRACTED , FROM * INDEXES AND CROSS REFERENCES CHAPTER 4...at E&V techniques through many different paths, and provides a means to extract useful information along the way. /^c^^s; /r^ ^yr*•**•»» * L...electronically (preferred) to szymansk@ajpo.sei.cmu.edu or by regular mail to Mr. Raymond Szymanski . AFWAUAAAF, Wright Patterson AFB, OH 45433-6543. ES-2

  6. Geometric registration of images by similarity transformation using two reference points

    NASA Technical Reports Server (NTRS)

    Kang, Yong Q. (Inventor); Jo, Young-Heon (Inventor); Yan, Xiao-Hai (Inventor)

    2011-01-01

    A method for registering a first image to a second image using a similarity transformation. The each image includes a plurality of pixels. The first image pixels are mapped to a set of first image coordinates and the second image pixels are mapped to a set of second image coordinates. The first image coordinates of two reference points in the first image are determined. The second image coordinates of these reference points in the second image are determined. A Cartesian translation of the set of second image coordinates is performed such that the second image coordinates of the first reference point match its first image coordinates. A similarity transformation of the translated set of second image coordinates is performed. This transformation scales and rotates the second image coordinates about the first reference point such that the second image coordinates of the second reference point match its first image coordinates.

  7. Nitrate induces a type 1 diabetic profile in alligator hatchlings.

    PubMed

    Edwards, Thea M; Hamlin, Heather J; Freymiller, Haley; Green, Stephen; Thurman, Jenna; Guillette, Louis J

    2018-01-01

    Type 1 diabetes (T1D) is a chronic autoimmune disease that affects 1 in 300 children by age 18. T1D is caused by inflammation-induced loss of insulin-producing pancreatic beta cells, leading to high blood glucose and a host of downstream complications. Although multiple genes are associated with T1D risk, only 5% of genetically susceptible individuals actually develop clinical disease. Moreover, a growing number of T1D cases occur in geographic clusters and among children with low risk genotypes. These observations suggest that environmental factors contribute to T1D etiology. One potential factor, supported primarily by epidemiological studies, is the presence of nitrate and nitrite in drinking water. To test this hypothesis, female hatchling alligators were exposed to environmentally relevant concentrations of nitrate in their tank water (reference, 10mg/L, or 100mg/L NO 3 -N) from hatch through 5 weeks or 5 months of age. At each time point, endpoints related to T1D were investigated: plasma levels of glucose, triglycerides, testosterone, estradiol, and thyroxine; pancreas, fat body, and thyroid weights; weight gain or loss; presence of immune cells in the pancreas; and pancreatic beta cell number, assessed by antibody staining of nkx6.1 protein. Internal dosing of nitrate was confirmed by measuring plasma and urine nitrate levels and whole blood methemoglobin. Cluster analysis indicated that high nitrate exposure (most animals exposed to 100mg/L NO3-N and one alligator exposed to 10mg/L NO3-N) induced a profile of endpoints consistent with early T1D that could be detected after 5 weeks and was more strongly present after 5 months. Our study supports epidemiological data correlating elevated nitrate with T1D onset in humans, and highlights nitrate as a possible environmental contributor to the etiology of T1D, possibly through its role as a nitric oxide precursor. Copyright © 2017 Elsevier Inc. All rights reserved.

  8. Plasma chemistry reference values in ostriches.

    PubMed

    Verstappen, F A L M; Lumeij, J T; Bronneberg, R G G

    2002-01-01

    Reference values for 18 plasma chemical variables in blue neck ostriches (Struthio camelus australis, n = 60, age 24-36 mo) were established for use in veterinary clinical practice using nonparametric statistics. The following values were established for the percentiles P2.5 and P97.5: sodium 147-157 mmol/L, calcium 2.4-4.8 mmol/L, inorganic phosphate 1.3-2.3 mmol/L, chloride 94-105 mmol/L, glucose 10.3-13.7 mmol/L, urea 0.5-0.8 mmol/L, uric acid 351-649 mumol/L, bile acids 8-33 mumol/L, total protein 39-56 g/L, albumin-globulin ratio 0.45-0.59, osmolality 304-330 mOsm/kg, alkaline phosphate 69-217 IU/L, aspartate aminotransferase 243-418 IU/L, gamma-glutamyltransferase 0-1 IU/L, creatine kinase 1648-4894 IU/L, glutamate dehydrogenase 8-17 IU/L, and lactate dehydrogenase 860-2236 IU/L. The plasma calcium concentration was significantly (P < 0.001; r = 0.74) related to the total protein concentration and an adjustment-formula for calcium was derived: adjusted Ca (mmol/L) = Ca (mmol/L)--0.09 TP (g/L) + 4.4. The influence of blood sample treatment on the plasma potassium concentration as seen in other avian species was demonstrated in a separate experiment, emphasizing the need to separate plasma and cells immediately after collection in avian blood samples.

  9. Cure of tuberculosis despite serum concentrations of antituberculosis drugs below published reference ranges.

    PubMed

    Meloni, Monica; Corti, Natascia; Müller, Daniel; Henning, Lars; Gutteck, Ursula; von Braun, Amrei; Weber, Rainer; Fehr, Jan

    2015-01-01

    Therapeutic target serum concentrations of first-line antituberculosis drugs have not been well defined in clinical studies in tuberculosis (TB) patients. We retrospectively investigated the estimated maximum serum concentrations (eC max) of antituberculosis drugs and clinical outcome of TB patients with therapeutic drug monitoring performed between 2010-2012 at our institution, and follow-up until March 2014. The eC max was defined as the highest serum concentration during a sampling period (2, 4 and 6 hours after drug ingestion). We compared the results with published eC max values, and categorised them as either "within reference range", "low eC max", or "very low eC max".Low/very low eC max-levels were defined as follows: isoniazid 2-3/<2 mg/l, rifampicin 4-8/<4 mg/l, rifabutin 0.2-0.3/<0.2 mg/l, ethambutol 1-2/<0.1 mg/l and pyrazinamide <20 mg/l. Concentrations of antituberculosis drugs in 175 serum samples of 17 patients with TB were analysed. In 12 (71%) patients, multiple therapeutic drug monitoring samples were collected over time, in 5 (29%) patients only one sample was available for therapeutic drug monitoring. Overall, 94% of all patients had at least one low antituberculosis drug concentration. Overall, 64% of all eC max levels were classified as "low" or "very low". The eC max was below the relevant reference range in 80% of isoniazid, 95% of rifampicin, 30% of pyrazinamide, and 30% of ethambutol measurements. All but one patient were cured of tuberculosis. Although many antituberculosis drug serum concentrations were below the widely used reference ranges, 16 of 17 patients were cured of tuberculosis. These results challenge the use of the published reference ranges for therapeutic drug monitoring.

  10. Assessment of natural background radiation in one of the highest regions of Ecuador

    NASA Astrophysics Data System (ADS)

    Pérez, Mario; Chávez, Estefanía; Echeverría, Magdy; Córdova, Rafael; Recalde, Celso

    2018-05-01

    Natural background radiation was measured in the province of Chimborazo (Ecuador) with the following reference coordinates 1°40'00''S 78°39'00''W, where the furthest point to the center of the planet is located. Natural background radiation measurements were performed at 130 randomly selected sites using a Geiger Müller GCA-07W portable detector; these measurements were run at 6 m away from buildings or walls and 1 m above the ground. The global average natural background radiation established by UNSCEAR is 2.4 mSv y-1. In the study area measurements ranged from 0.57 mSv y-1 to 3.09 mSv y-1 with a mean value of 1.57 mSv y-1, the maximum value was recorded in the north of the study area at 5073 metres above sea level (m.a.s.l.), and the minimum value was recorded in the southwestern area at 297 m.a.s.l. An isodose map was plotted to represent the equivalent dose rate due to natural background radiation. An analysis of variance (ANOVA) between the data of the high and low regions of the study area showed a significant difference (p < α), in addition a linear correlation coefficient of 0.92 was obtained, supporting the hypothesis that in high altitude zones extraterrestrial radiation contributes significantly to natural background radiation.

  11. Salt marsh ecosystem biogeochemical responses to nutrient enrichment: a paired 15N tracer study.

    PubMed

    Drake, D C; Peterson, Bruce J; Galván, Kari A; Deegan, Linda A; Hopkinson, Charles; Johnson, J Michael; Koop-Jakobsen, K; Lemay, Lynsey E; Picard, Christian

    2009-09-01

    We compared processing and fate of dissolved NO3- in two New England salt marsh ecosystems, one receiving natural flood tide concentrations of approximately 1-4 micromol NO3-/ L and the other receiving experimentally fertilized flood tides containing approximately 70-100 micromol NO3-/ L. We conducted simultaneous 15NO3- (isotope) tracer additions from 23 to 28 July 2005 in the reference (8.4 ha) and fertilized (12.4 ha) systems to compare N dynamics and fate. Two full tidal cycles were intensively studied during the paired tracer additions. Resulting mass balances showed that essentially 100% (0.48-0.61 mol NO3-N.ha(-1).h(-1)) of incoming NO3- was assimilated, dissimilated, sorbed, or sedimented (processed) within a few hours in the reference system when NO3- concentrations were 1.3-1.8 micromol/L. In contrast, only 50-60% of incoming NO3- was processed in the fertilized system when NO3- concentrations were 84-96 micromol/L; the remainder was exported in ebb tidewater. Gross NO3- processing was approximately 40 times higher in the fertilized system at 19.34-24.67 mol NO3-N.ha(-1).h(-1). Dissimilatory nitrate reduction to ammonium was evident in both systems during the first 48 h of the tracer additions but <1% of incoming 15NO3- was exported as 15NH4+. Nitrification rates calculated by 15NO3- dilution were 6.05 and 4.46 mol.ha(-1).h(-1) in the fertilized system but could not be accurately calculated in the reference system due to rapid (<4 h) NO3- turnover. Over the five-day paired tracer addition, sediments sequestered a small fraction of incoming NO3-, although the efficiency of sequestration was 3.8% in the reference system and 0.7% in the fertilized system. Gross sediment N sequestration rates were similar at 13.5 and 12.6 mol.ha(-1).d(-1), respectively. Macrophyte NO3- uptake efficiency, based on tracer incorporation in aboveground tissues, was considerably higher in the reference system (16.8%) than the fertilized system (2.6%), although bulk uptake of NO3- by plants was lower in the reference system (1.75 mol NO3-.ha(-1).d(-1)) than the fertilized system (approximately 10 mol NO3-.ha(-1).d(-1)). Nitrogen processing efficiency decreased with NO3- load in all pools, suggesting that the nutrient processing capacity of the marsh ecosystem was exceeded in the fertilized marsh.

  12. Automatic Alignment of Displacement-Measuring Interferometer

    NASA Technical Reports Server (NTRS)

    Halverson, Peter; Regehr, Martin; Spero, Robert; Alvarez-Salazar, Oscar; Loya, Frank; Logan, Jennifer

    2006-01-01

    A control system strives to maintain the correct alignment of a laser beam in an interferometer dedicated to measuring the displacement or distance between two fiducial corner-cube reflectors. The correct alignment of the laser beam is parallel to the line between the corner points of the corner-cube reflectors: Any deviation from parallelism changes the length of the optical path between the reflectors, thereby introducing a displacement or distance measurement error. On the basis of the geometrical optics of corner-cube reflectors, the length of the optical path can be shown to be L = L(sub 0)cos theta, where L(sub 0) is the distance between the corner points and theta is the misalignment angle. Therefore, the measurement error is given by DeltaL = L(sub 0)(cos theta - 1). In the usual case in which the misalignment is small, this error can be approximated as DeltaL approximately equal to -L(sub 0)theta sup 2/2. The control system (see figure) is implemented partly in hardware and partly in software. The control system includes three piezoelectric actuators for rapid, fine adjustment of the direction of the laser beam. The voltages applied to the piezoelectric actuators include components designed to scan the beam in a circular pattern so that the beam traces out a narrow cone (60 microradians wide in the initial application) about the direction in which it is nominally aimed. This scan is performed at a frequency (2.5 Hz in the initial application) well below the resonance frequency of any vibration of the interferometer. The laser beam makes a round trip to both corner-cube reflectors and then interferes with the launched beam. The interference is detected on a photodiode. The length of the optical path is measured by a heterodyne technique: A 100- kHz frequency shift between the launched beam and a reference beam imposes, on the detected signal, an interferometric phase shift proportional to the length of the optical path. A phase meter comprising analog filters and specialized digital circuitry converts the phase shift to an indication of displacement, generating a digital signal proportional to the path length.

  13. Erratum: ``The Luminosity Function of IRAS Point Source Catalog Redshift Survey Galaxies'' (ApJ, 587, L89 [2003])

    NASA Astrophysics Data System (ADS)

    Takeuchi, Tsutomu T.; Yoshikawa, Kohji; Ishii, Takako T.

    2004-05-01

    We have mentioned that we normalized the parameters for the luminosity function by the Hubble constant H0=100 km s-1 Mpc-1 however, for the characteristic luminosity L* we erroneously normalized it by H0=70 km s-1 Mpc-1. As a result, we have proposed wrong numerical factors for L*. In addition, there is a typographic error in the exponent of equation (6) of the published manuscript. Correct values are as follows: L*=(4.34+/-0.86)×108 h-2 [Lsolar] for equation (4), and L*=(2.50+/-0.44)×109 h-2 [Lsolar] and L*=(9.55+/-0.20)×108 h-2 [Lsolar] for equations (5) and (6), respectively. All the other parameters are correct. The errors have occurred only in the final conversion, and they do not affect our discussions and conclusions at all. We thank P. Ranalli for pointing out the errors.

  14. Salt-front movement in the Hudson River estuary, New York—Simulations by one-dimensional flow and solute-transport models

    USGS Publications Warehouse

    de Vries, M. Peter; Weiss, Lawrence A.

    2001-01-01

    The Hudson River is being considered for use as a supplemental source of water supply for New York City during droughts. One proposal entails withdrawal of Hudson River water from locations near Newburgh, Chelsea, or Kingston, but the extent to which this could cause the salt front to advance upstream to points where it could adversely affect community water supplies is unknown. The U.S. Geological Survey (USGS) one-dimensional Branch-Network Dynamic Flow model (BRANCH) was used in conjunction with the USGS one-dimensional Branched Lagrangian Solute-Transport Model (BLTM) to simulate the effect of five water-withdrawal scenarios on the salt-front location.The modeled reach contains 132 miles of the lower Hudson River between the Federal Dam at Troy and Hastings-on-Hudson (near New York City). The BRANCH model was calibrated and verified to 19 tidal-cycle discharge measurements made at 11 locations by conventional and acoustic Doppler current-profiler methods. Maximum measured instantaneous tidal flow ranged from 20,000 ft3/s (cubic feet per second) at Albany to 368,000 ft3/s at Tellers Point; daily-mean flow at Green Island near Troy ranged from 3,030 ft3/s to 45,000 ft3/s during the flow measurements. Successive ebb- and flood-flow volumes were measured and compared with computed volumes; daily-mean bias was -1.6 percent (range from -21.0 to +23.7 percent; 13.5 percent mean absolute error). Daily-mean deviation between simulated and measured stage at eight locations (from Bowline Point to Albany) over the 19 tidal-cycle measurements averaged +0.06 ft (range from -0.31 to +0.40 ft; 0.21 ft root mean square error, RMSE). These results indicate that the model can accurately simulate flow in the Hudson River under a wide range of flow, tide, and meteorological conditions.The BLTM was used to simulate chloride transport in the 61-mi reach from Turkey Point to Bowline Point under two seasonal conditions in 1990.one representing spring conditions of high inflow and low salinity (April-June), the other representing typical summer conditions of low inflow and high salinity (July-August). Measured chloride concentrations at Bowline Point were used to drive the BLTM simulations, and data collected at West Point were used for calibration. Mean bias in simulated chloride concentration for the April-June 1990 (high flow) data (observed range from 12 to 201 mg/L [milligrams per liter]; 30 mg/L RMSE) was .16 mg/L, and mean bias for the July-August 1990 (low flow) data (observed range from 31 to 2,000 mg/L; 535 mg/ L RMSE) was +126 mg/L. The salt front (saltwater/ freshwater interface) on the Hudson River was defined as the furthest upstream location where the chloride concentration exceeded 100 mg/L. Data from August 1991 were used to evaluate solute transport between West Point and Poughkeepsie because a chloride concentration of 100 mg/L was not observed at Clinton Point in 1990. The BLTM then was used to simulate chloride concentrations at Chelsea Pump Station and Clinton Point. Regression equations, based on daily mean values of specific conductance measured at West Point, were used to estimate daily mean chloride concentrations at Chelsea Pump Station and Clinton Point for model analysis. Mean biases in BLTM-simulated daily mean chloride concentrations for August 1991 were .38 mg/L at Chelsea Pump Station (range from 189 to 551 mg/L; 103 mg/L RMSE) and .9 mg/L at Clinton Point (range from 53 to 264 mg/L; 62 mg/L RMSE).Hypothetical withdrawals at (1) Newburgh, (2) Chelsea, (3) Chelsea and Newburgh, (4) Chelsea and Kingston, and (5) Kingston and Newburgh, were simulated to compute the effects of withdrawals on salt-front movement. Withdrawals of 300 Mgal/d from any combination of Chelsea or Newburgh could result in upstream movement of the salt front of as much as 1.0 mi, given an initial salt-front location between West Point and Rogers Point. Scenarios that included withdrawals at Kingston caused the greatest upstream salt-front movement. Simulation of a 90-day April-June high-flow period during which discharges at Green Island averaged 25,200 ft3/s indicated that withdrawals of 1,939 Mgal/d (million gallons per day) at Chelsea Pump Station would not measureably increase chloride concentrations at Chelsea Pump Station under normal tidal and meteorological conditions, but withdrawals at twice that rate (3,878 Mgal/d) could increase the chloride concentration at Chelsea Pump Station to 250 mg/L.

  15. Use of continuous glucose monitoring as an outcome measure in clinical trials.

    PubMed

    Beck, Roy W; Calhoun, Peter; Kollman, Craig

    2012-10-01

    Although developed to be a management tool for individuals with diabetes, continuous glucose monitoring (CGM) also has potential value for the assessment of outcomes in clinical studies. We evaluated using CGM as such an outcome measure. Data were analyzed from six previously completed inpatient studies in which both CGM (Freestyle Navigator™ [Abbott Diabetes Care, Alameda, CA] or Guardian(®) [Medtronic, Northridge, CA]) and reference glucose measurements were available. The analyses included 97 days of data from 93 participants with type 1 diabetes (age range, 5-57 years; mean, 18 ± 12 years). Mean glucose levels per day were similar for the CGM and reference measurements (median, 148 mg/dL vs. 143 mg/dL, respectively; P = 0.92), and the correlation of the two was high (r = 0.89). Similarly, most glycemia metrics showed no significant differences comparing CGM and reference values, except that the nadir glucose tended to be slightly lower and peak glucose slightly higher with reference measurements than CGM measurements (respective median, 59 mg/dL vs. 66 mg/dL [P = 0.05] and 262 mg/dL vs. 257 mg/dL [P = 0.003]) and glucose variability as measured with the coefficient of variation was slightly lower with CGM than reference measurements (respective median, 31% vs. 35%; P<0.001). A reasonably high degree of concordance exists when comparing outcomes based on CGM measurements with outcomes based on reference blood glucose measurements. CGM inaccuracy and underestimation of the extremes of hyperglycemia and hypoglycemia can be accounted for in a clinical trial's study design. Thus, in appropriate settings, CGM can be a very meaningful and feasible outcome measure for clinical trials.

  16. Use of Continuous Glucose Monitoring as an Outcome Measure in Clinical Trials

    PubMed Central

    Calhoun, Peter; Kollman, Craig

    2012-01-01

    Abstract Objective Although developed to be a management tool for individuals with diabetes, continuous glucose monitoring (CGM) also has potential value for the assessment of outcomes in clinical studies. We evaluated using CGM as such an outcome measure. Research Design and Methods Data were analyzed from six previously completed inpatient studies in which both CGM (Freestyle Navigator™ [Abbott Diabetes Care, Alameda, CA] or Guardian® [Medtronic, Northridge, CA]) and reference glucose measurements were available. The analyses included 97 days of data from 93 participants with type 1 diabetes (age range, 5–57 years; mean, 18±12 years). Results Mean glucose levels per day were similar for the CGM and reference measurements (median, 148 mg/dL vs. 143 mg/dL, respectively; P=0.92), and the correlation of the two was high (r=0.89). Similarly, most glycemia metrics showed no significant differences comparing CGM and reference values, except that the nadir glucose tended to be slightly lower and peak glucose slightly higher with reference measurements than CGM measurements (respective median, 59 mg/dL vs. 66 mg/dL [P=0.05] and 262 mg/dL vs. 257 mg/dL [P=0.003]) and glucose variability as measured with the coefficient of variation was slightly lower with CGM than reference measurements (respective median, 31% vs. 35%; P<0.001). Conclusions A reasonably high degree of concordance exists when comparing outcomes based on CGM measurements with outcomes based on reference blood glucose measurements. CGM inaccuracy and underestimation of the extremes of hyperglycemia and hypoglycemia can be accounted for in a clinical trial's study design. Thus, in appropriate settings, CGM can be a very meaningful and feasible outcome measure for clinical trials. PMID:23013201

  17. Diagnostic value of sputum adenosine deaminase (ADA) level in pulmonary tuberculosis.

    PubMed

    Binesh, Fariba; Jalali, Hadi; Zare, Mohammad Reza; Behravan, Farhad; Tafti, Arefeh Dehghani; Behnaz, Fatemah; Tabatabaee, Mohammad; Shahcheraghi, Seyed Hossein

    2016-06-01

    Tuberculosis is still a considerable health problem in many countries. Rapid diagnosis of this disease is important, and adenosine deaminase (ADA) has been used as a diagnostic test. The aim of this study was to assess the diagnostic value of ADA in the sputum of patients with pulmonary tuberculosis. The current study included 40 patients with pulmonary tuberculosis (culture positive, smear ±) and 42 patients with non tuberculosis pulmonary diseases (culture negative). ADA was measured on all of the samples. The median value of ADA in non-tuberculosis patients was 2.94 (4.2) U/L and 4.01 (6.54) U/L in tuberculosis patients, but this difference was not statistically significant (p=0.100). The cut-off point of 3.1 U/L had a sensitivity of 61% and a specificity of 53%, the cut-off point of 2.81 U/L had a sensitivity of 64% and a specificity of 50% and the cut-off point of 2.78 U/L had a sensitivity of 65% and a specificity of 48%. The positive predictive values for cut-off points of 3.1, 2.81 and 2.78 U/L were 55.7%, 57.44% and 69.23%, respectively. The negative predictive values for the abovementioned cut-off points were 56.75%, 57.14% and 55.88%, respectively. Our results showed that sputum ADA test is neither specific nor sensitive. Because of its low sensitivity and specificity, determination of sputum ADA for the diagnosis of pulmonary tuberculosis is not recommended.

  18. A new function for estimating local rainfall thresholds for landslide triggering

    NASA Astrophysics Data System (ADS)

    Cepeda, J.; Nadim, F.; Høeg, K.; Elverhøi, A.

    2009-04-01

    The widely used power law for establishing rainfall thresholds for triggering of landslides was first proposed by N. Caine in 1980. The most updated global thresholds presented by F. Guzzetti and co-workers in 2008 were derived using Caine's power law and a rigorous and comprehensive collection of global data. Caine's function is defined as I = α×Dβ, where I and D are the mean intensity and total duration of rainfall, and α and β are parameters estimated for a lower boundary curve to most or all the positive observations (i.e., landslide triggering rainfall events). This function does not account for the effect of antecedent precipitation as a conditioning factor for slope instability, an approach that may be adequate for global or regional thresholds that include landslides in surface geologies with a wide range of subsurface drainage conditions and pore-pressure responses to sustained rainfall. However, in a local scale and in geological settings dominated by a narrow range of drainage conditions and behaviours of pore-pressure response, the inclusion of antecedent precipitation in the definition of thresholds becomes necessary in order to ensure their optimum performance, especially when used as part of early warning systems (i.e., false alarms and missed events must be kept to a minimum). Some authors have incorporated the effect of antecedent rainfall in a discrete manner by first comparing the accumulated precipitation during a specified number of days against a reference value and then using a Caine's function threshold only when that reference value is exceeded. The approach in other authors has been to calculate threshold values as linear combinations of several triggering and antecedent parameters. The present study is aimed to proposing a new threshold function based on a generalisation of Caine's power law. The proposed function has the form I = (α1×Anα2)×Dβ, where I and D are defined as previously. The expression in parentheses is equivalent to Caine's α parameter. α1, α2 and β are parameters estimated for the threshold. An is the n-days cumulative rainfall. The suggested procedure to estimate the threshold is as follows: (1) Given N storms, assign one of the following flags to each storm: nL (non-triggering storms), yL (triggering storms), uL (uncertain-triggering storms). Successful predictions correspond to nL and yL storms occurring below and above the threshold, respectively. Storms flagged as uL are actually assigned either an nL or yL flag using a randomization procedure. (2) Establish a set of values of ni (e.g. 1, 4, 7, 10, 15 days, etc.) to test for accumulated precipitation. (3) For each storm and each ni value, obtain the antecedent accumulated precipitation in ni days Ani. (4) Generate a 3D grid of values of α1, α2 and β. (5) For a certain value of ni, generate confusion matrices for the N storms at each grid point and estimate an evaluation metrics parameter EMP (e.g., accuracy, specificity, etc.). (6) Repeat the previous step for all the set of ni values. (7) From the 3D grid corresponding to each ni value, search for the optimum grid point EMPopti(global minimum or maximum parameter). (8) Search for the optimum value of ni in the space ni vs EMPopti . (9) The threshold is defined by the value of ni obtained in the previous step and the corresponding values of α1, α2 and β. The procedure is illustrated using rainfall data and landslide observations from the San Salvador volcano, where a rainfall-triggered debris flow destroyed a neighbourhood in the capital city of El Salvador in 19 September, 1982, killing not less than 300 people.

  19. Constructing the L2-Graph for Robust Subspace Learning and Subspace Clustering.

    PubMed

    Peng, Xi; Yu, Zhiding; Yi, Zhang; Tang, Huajin

    2017-04-01

    Under the framework of graph-based learning, the key to robust subspace clustering and subspace learning is to obtain a good similarity graph that eliminates the effects of errors and retains only connections between the data points from the same subspace (i.e., intrasubspace data points). Recent works achieve good performance by modeling errors into their objective functions to remove the errors from the inputs. However, these approaches face the limitations that the structure of errors should be known prior and a complex convex problem must be solved. In this paper, we present a novel method to eliminate the effects of the errors from the projection space (representation) rather than from the input space. We first prove that l 1 -, l 2 -, l ∞ -, and nuclear-norm-based linear projection spaces share the property of intrasubspace projection dominance, i.e., the coefficients over intrasubspace data points are larger than those over intersubspace data points. Based on this property, we introduce a method to construct a sparse similarity graph, called L2-graph. The subspace clustering and subspace learning algorithms are developed upon L2-graph. We conduct comprehensive experiment on subspace learning, image clustering, and motion segmentation and consider several quantitative benchmarks classification/clustering accuracy, normalized mutual information, and running time. Results show that L2-graph outperforms many state-of-the-art methods in our experiments, including L1-graph, low rank representation (LRR), and latent LRR, least square regression, sparse subspace clustering, and locally linear representation.

  20. Raised serum lactate: a marker of necrotizing fasciitis?

    PubMed

    Murphy, George; Markeson, Daniel; Choa, Robert; Armstrong, Anthony

    2013-12-01

    Distinguishing necrotizing fasciitis from non-necrotizing soft-tissue infections remains a difficult clinical judgement call, with a paucity of diagnostic aids to the clinician. The aim of this study was to assess raised serum lactate as a point-of-care test to aid in differentiating necrotizing from non-necrotizing soft tissue infections. The authors performed a post-hoc analysis of a prospectively compiled database. All patients referred to a single surgeon (A.P.A.) as suspected cases of necrotizing fasciitis at one hospital between September 2000 and September 2010 were included. Serum lactate at presentation was recorded, along with demographic and outcome data. Using histological evidence of tissue necrosis as the 'gold standard', patients were divided into those with or without necrotizing fasciitis, and their serum lactate at presentation compared. Fifty three patients met the inclusion criteria. Twenty eight had histologically proven necrosis, 25 did not. Serum lactate (mean±SD) was 4.1±1.62 mmol/l in the necrotizing fasciitis group and 1.8±0.46 mmol/l in the non-necrotizing fasciitis group (p≤0.0001). A serum lactate level above 2.0 mmol/l had a sensitivity of 1.00 and a specificity of 0.76 for necrotizing fasciitis in this series. In this series of patients with suspected necrotizing soft tissue infection, serum lactate levels above 2.0 mmol/l at presentation were strongly associated with the presence of tissue necrosis. Although no test can be relied upon in isolation, our results suggest that serum lactate is a promising adjunct to the diagnosis of necrotizing infection, which could help to expedite appropriate management. Copyright © 2013 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  1. Planetary Defense From Space: Part 1-Keplerian Theory

    NASA Astrophysics Data System (ADS)

    Maccone, Claudio

    A system of two space bases housing missiles is proposed to achieve the Planetary Defense of the Earth against dangerous asteroids and comets. We show that the layout of the Earth-Moon system with the five relevant Lagrangian (or libration) points in space leads naturally to only one, unmistakable location of these two space bases within the sphere of influence of the Earth. These locations are at the two Lagrangian points L1 (in between the Earth and the Moon) and L3 (in the direction opposite to the Moon from the Earth). We show that placing bases of missiles at L1 and L3 would cause those missiles to deflect the trajectory of asteroids by hitting them orthogonally to their impact trajectory toward the Earth, so as to maximize their deflection. We show that the confocal conics are the best class of trajectories fulfilling this orthogonal deflection requirement. An additional remark is that the theory developed in this paper is just a beginning of a larger set of future research work. In fact, while in this paper we only develop the Keplerian analytical theory of the Optimal Planetary Defense achievable from the Earth-Moon Lagrangian points L1 and L3, much more sophisticated analytical refinements would be needed to: Take into account many perturbation forces of all kinds acting on both the asteroids and missiles shot from L1 and L3; add more (non-optimal) trajectories of missiles shot from either the Lagrangian points L4 and L5 of the Earth-Moon system or from the surface of the Moon itself; encompass the full range of missiles currently available to the US (and possibly other countries) so as to really see "which asteroids could be diverted by which missiles", even in the very simplified scheme outlined here. Outlined for the first time in February 2002, our Confocal Planetary Defense concept is a Keplerian Theory that proved simple enough to catch the attention of scholars, representatives of the US Military and popular writers. These developments could possibly mark the beginning of an "all embracing" mathematical vision of Planetary Defense beyond all learned activities, dramatic movies and unknown military plans covered by secret.

  2. Radiation resistance of lactobacilli isolated from radurized meat relative to growth and environment. [Lactobacillus sake; Lactobacillus curvatus; Lactobacillus farciminis; Staphylococcus aureus; Salmonella typimurium

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hastings, J.W.; Holzapfel, W.H.; Niemand, J.G.

    1986-10-01

    Of 113 lactobacilli isolated from radurized (5 kGy) minced meat, 7 Lactobacillus sake strains, 1 L. curvatus strain, and 1 L. farciminis strain were used for radiation resistance studies in a semisynthetic substrate (i.e., modified MRS broth). Five reference Lactobacillus spp. one Staphylococcus aureus strain, and one Salmonella typhimurium strain were used for comparative purposes. All L. sake isolates exhibited the phenomenon of being more resistant to gamma-irradiation in the exponential (log) phase than in the stationary phase of their growth cycles by a factor of 28%. Four reference strains also exhibited this phenomenon, with L. sake (DSM 20017) showingmore » a 68% increase in resistance in the log phase over the stationary phase. This phenomenon was not common to all bacteria tested and is not common to all strains with high radiation resistance. Four L. sake isolates and three reference strains were used in radiation sensitivity testing in a natural food system (i.e., meat). The bacteria were irradiated in minced meat and packaged under four different conditions (air, vacuum, CO/sub 2/, and N/sub 2/). Organisms exhibited the highest death rate (lowest D/sub 10/ values (doses required to reduce the logarithm of the bacterial population by 1) under CO/sub 2/ packaging conditions, but resistance to irradiation was increased under N/sub 2/. The D/sup 10/ values of the isolates were generally greater than those of the reference strains. The D/sup 10/ values were also higher (approximately two times) in meat than in a semisynthetic growth medium.« less

  3. 26 CFR 1.1502-95 - Rules on ceasing to be a member of a consolidated group (or loss subgroup).

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... (other than the L1 and L2 stock), asset 1 with an adjusted basis of $40 and a fair market value of $15... of the L2 stock to M. At that time, asset 5, which has appreciated in value, has a fair market value... reference to a subgroup section 382 limitation. (2) Election by common parent. Only the common parent (not...

  4. 47 CFR 76.53 - Reference points.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 47 Telecommunication 4 2011-10-01 2011-10-01 false Reference points. 76.53 Section 76.53 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) BROADCAST RADIO SERVICES MULTICHANNEL VIDEO AND CABLE TELEVISION SERVICE Carriage of Television Broadcast Signals § 76.53 Reference points. The...

  5. 47 CFR 76.53 - Reference points.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 47 Telecommunication 4 2013-10-01 2013-10-01 false Reference points. 76.53 Section 76.53 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) BROADCAST RADIO SERVICES MULTICHANNEL VIDEO AND CABLE TELEVISION SERVICE Carriage of Television Broadcast Signals § 76.53 Reference points. The...

  6. 47 CFR 76.53 - Reference points.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 47 Telecommunication 4 2014-10-01 2014-10-01 false Reference points. 76.53 Section 76.53 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) BROADCAST RADIO SERVICES MULTICHANNEL VIDEO AND CABLE TELEVISION SERVICE Carriage of Television Broadcast Signals § 76.53 Reference points. The...

  7. 47 CFR 76.53 - Reference points.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 47 Telecommunication 4 2012-10-01 2012-10-01 false Reference points. 76.53 Section 76.53 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) BROADCAST RADIO SERVICES MULTICHANNEL VIDEO AND CABLE TELEVISION SERVICE Carriage of Television Broadcast Signals § 76.53 Reference points. The...

  8. [Pharmacokinetics and bioequivalence of atorvastatin calcium tablets in healthy male Chinese volunteers].

    PubMed

    Shen, Yi; Zhang, Yi-fan; Chen, Xiao-yan; Guo, Li-xia; Zhong, Da-fang

    2012-03-01

    To compare the bioequivalence and pharmacokinetics of national made and imported atorvastatin in healthy male Chinese volunteers after single oral administration. This randomized sequence, open-label, two-period crossover study with a one-week washout period between doses was performed in 24 fasting healthy Chinese males. They were randomly assigned to receive 20 mg of either the test (national made) or reference (imported) formulation orally. The blood samples were collected over a 72-hour period. Plasma concentrations of parent atorvastatin (AT), ortho-hydroxy-atorvastatin (o-OAT) and para-hydroxy-atorvastatin (p-OAT) were simultaneously determined using the validated liquid chromatography-tandem mass spectrometry method, the bioequivalence was also evaluated throughout the study. The main pharmacokinetic parameters of test and reference formulations were as follows: the values of C(max) for AT were (10.6 ± 11.9) µg/L and (10.6 ± 9.8) µg/L, t(1/2z) were (11.4 ± 3.9) h and (11.4 ± 5.3) h, AUC(0-t) were (54.2 ± 37.4) µg×h(-1)×L(-1) and (51.7 ± 34.1) µg×h(-1)×L(-1), respectively. The values of C(max) for o-OAT were (7.8 ± 4.5) µg/L and (7.6 ± 4.3) µg/L, t(1/2z) were (12.3 ± 4.2) h and (11.9 ± 3.4) h, AUC(0-t) were (96.8 ± 48.2) µg×h(-1)×L(-1) and (92.3 ± 44.4) µg×h(-1)×L(-1), respectively. The values of C(max) for p-OAT were (0.5 ± 0.4) µg/L and (0.4 ± 0.3) µg/L, t(1/2z) were (18.4 ± 12.4) h and (23.3 ± 17.8) h, AUC(0-t) were (15.9 ± 12.3) µg×h(-1)×L(-1) and (13.8 ± 8.11) µg×h(-1)×L(-1), respectively. The relative bioavailability of AT and o-OAT in test formulation were (105.3 ± 20.7)% and (107.8 ± 23.2)%, respectively. The 90% confidence interval of the test/reference geometric mean ratios of AUC(0-t) for AT and o-OAT were (97.7 - 110.5)% and (98.3 - 111.3)%, C(max) for AT and o-OAT were (75.8 - 114.0)% and (90.6 - 122.9)%, they were all located within the bioequivalence criteria range (80% - 125% for AUC, and 70% - 143% for C(max)). The result demonstrated that two formulations were bioequivalent.

  9. Determination of carcinogenic herbicides in milk samples using green non-ionic silicone surfactant of cloud point extraction and spectrophotometry.

    PubMed

    Mohd, N I; Zain, N N M; Raoov, M; Mohamad, S

    2018-04-01

    A new cloud point methodology was successfully used for the extraction of carcinogenic pesticides in milk samples as a prior step to their determination by spectrophotometry. In this work, non-ionic silicone surfactant, also known as 3-(3-hydroxypropyl-heptatrimethylxyloxane), was chosen as a green extraction solvent because of its structure and properties. The effect of different parameters, such as the type of surfactant, concentration and volume of surfactant, pH, salt, temperature, incubation time and water content on the cloud point extraction of carcinogenic pesticides such as atrazine and propazine, was studied in detail and a set of optimum conditions was established. A good correlation coefficient ( R 2 ) in the range of 0.991-0.997 for all calibration curves was obtained. The limit of detection was 1.06 µg l -1 (atrazine) and 1.22 µg l -1 (propazine), and the limit of quantitation was 3.54 µg l -1 (atrazine) and 4.07 µg l -1 (propazine). Satisfactory recoveries in the range of 81-108% were determined in milk samples at 5 and 1000 µg l -1 , respectively, with low relative standard deviation, n  = 3 of 0.301-7.45% in milk matrices. The proposed method is very convenient, rapid, cost-effective and environmentally friendly for food analysis.

  10. Cold air investigation of 4 1/2-stage turbine with stage loading factor of 4.66 and high specific work output. 1: Overall performance

    NASA Technical Reports Server (NTRS)

    Whitney, W. J.; Behning, F. P.; Moffitt, T. P.; Hotz, G. M.

    1977-01-01

    The turbine developed design specific work output at design speed at a total pressure ratio of 6.745 with a corresponding efficiency of 0.855. The efficiency (0.855)was 3.1 points lower than the estimated efficiency quoted by the contractor in the design report and 0.7 of a point lower than that determined by a reference prediction method. The performance of the turbine, which was a forced vortex design, agreed with the performance determined by the prediction method to about the same extent as did the performance of three reference high stage loading factor turbines, which were free vortex designs.

  11. Passive serialization in a multitasking environment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hennessey, J.P.; Osisek, D.L.; Seigh, J.W. II

    1989-02-28

    In a multiprocessing system having a control program in which data objects are shared among processes, this patent describes a method for serializing references to a data object by the processes so as to prevent invalid references to the data object by any process when an operation requiring exclusive access is performed by another process, comprising the steps of: permitting the processes to reference data objects on a shared access basis without obtaining a shared lock; monitoring a point of execution of the control program which is common to all processes in the system, which occurs regularly in the process'more » execution and across which no references to any data object can be maintained by any process, except references using locks; establishing a system reference point which occurs after each process in the system has passed the point of execution at least once since the last such system reference point; requesting an operation requiring exclusive access on a selected data object; preventing subsequent references by other processes to the selected data object; waiting until two of the system references points have occurred; and then performing the requested operation.« less

  12. Arsenic Exposure and Age- and Sex-Specific Risk for Skin Lesions: A Population-Based Case–Referent Study in Bangladesh

    PubMed Central

    Rahman, Mahfuzar; Vahter, Marie; Sohel, Nazmul; Yunus, Muhammad; Wahed, Mohammad Abdul; Streatfield, Peter Kim; Ekström, Eva-Charlotte; Persson, Lars Åke

    2006-01-01

    Background The objective of this population-based case–referent study in Matlab, Bangladesh, was to assess the susceptibility to arsenic-induced skin lesions by age and sex, in a population drinking water from As-contaminated tube wells. Methods Identification of As-related skin lesions was carried out in three steps: a) screening of the entire population > 4 years of age (n = 166,934) by trained field teams; b) diagnosis of suspected As-related cases by physicians; and c) confirmation by experts based on physicians’ records and photographs. A total of 504 cases with skin lesions were confirmed. We randomly selected 2,201 referents from the Matlab health and demographic surveillance system; 1,955 were eligible, and 1,830 (94%) were available for participation in the study. Individual history of As exposure was based on information obtained during interviews and included all drinking-water sources used since 1970 and concentrations of As (assessed by atomic absorption spectrophotometry) in all the tube wells used. Results Cases had been exposed to As more than referents (average exposure since 1970: male cases, 200 μg/L; female cases, 211 μg/L; male referents, 143 μg/L; female referents, 155 μg/L). We found a dose–response relationship for both sexes (p < 0.001) and increased risk with increasing socioeconomic status. Males had a higher risk of obtaining skin lesions than females (odds ratio 10.9 vs. 5.78) in the highest average exposure quintile (p = 0.005). Start of As exposure (cumulative exposure) before 1 year of age was not associated with higher risk of obtaining skin lesions compared to start of As exposure later in life. Conclusions The results demonstrate that males are more susceptible than females to develop skin lesions when exposed to As in water from tube wells. PMID:17185274

  13. Cerebrospinal Fluid Glucose and Lactate: Age-Specific Reference Values and Implications for Clinical Practice

    PubMed Central

    Leen, Wilhelmina G.; Willemsen, Michèl A.; Wevers, Ron A.; Verbeek, Marcel M.

    2012-01-01

    Cerebrospinal fluid (CSF) analysis is an important tool in the diagnostic work-up of many neurological disorders, but reference ranges for CSF glucose, CSF/plasma glucose ratio and CSF lactate based on studies with large numbers of CSF samples are not available. Our aim was to define age-specific reference values. In 1993 The Nijmegen Observational CSF Study was started. Results of all CSF samples that were analyzed between 1993 and 2008 at our laboratory were systematically collected and stored in our computerized database. After exclusion of CSF samples with an unknown or elevated erythrocyte count, an elevated leucocyte count, elevated concentrations of bilirubin, free hemoglobin, or total protein 9,036 CSF samples were further studied for CSF glucose (n = 8,871), CSF/plasma glucose ratio (n = 4,516) and CSF lactate values (n = 7,614). CSF glucose, CSF/plasma glucose ratio and CSF lactate were age-, but not sex dependent. Age-specific reference ranges were defined as 5–95th percentile ranges. CSF glucose 5th percentile values ranged from 1.8 to 2.9 mmol/L and 95th percentile values from 3.8 to 5.6 mmol/L. CSF/plasma glucose ratio 5th percentile values ranged from 0.41 to 0.53 and 95th percentile values from 0.82 to 1.19. CSF lactate 5th percentile values ranged from 0.88 to 1.41 mmol/L and 95th percentile values from 2.00 to 2.71 mmol/L. Reference ranges for all three parameters were widest in neonates and narrowest in toddlers, with lower and upper limits increasing with age. These reference values allow a reliable interpretation of CSF results in everyday clinical practice. Furthermore, hypoglycemia was associated with an increased CSF/plasma glucose ratio, whereas hyperglycemia did not affect the CSF/plasma glucose ratio. PMID:22880096

  14. L1 vs L2 Writing: ESL Graduate Students' Perceptions.

    ERIC Educational Resources Information Center

    Silva, Tony

    1992-01-01

    A classroom-based study is reported that explored English-as-a-Second Language graduate students' perceptions about (1) differences between writing in their native language and writing in English, and (2) how these difference should be reflected in ESL writing teachers' practices. (19 references) (Author/LB)

  15. 21 CFR 172.133 - Dimethyl dicarbonate.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... titration Reference electrode Glass electrode reagents Acetone, analytical-grade Solution of 1 N... sample (W) and dissolve in 100 mL acetone. Add accurately 25 mL of the 1 N diisobutylamine solution by... the diisobutylamine solution, always use the same pipette and wait for a further three drops to fall...

  16. Optimal trajectories from the Earth-Moon L1 and L3 points to deflect hazardous asteroids and comets.

    PubMed

    Maccone, Claudio

    2004-05-01

    Software code named asteroff was recently created by the author to simulate the deflection of hazardous asteroids off of their collision course with the Earth. This code was both copyrighted and patented to avoid unauthorized use of ideas that could possibly be vital to construct a planetary defense system in the vicinity of the Earth. Having so said, the basic ideas and equations underlying the asteroff simulation code are openly described in this paper. A system of two space bases housing missiles is proposed to achieve the planetary defense of the Earth against dangerous asteroids and comets, collectively called impactors herein. We show that the layout of the Earth-Moon system with the five relevant Lagrangian (or libration) points in space leads naturally to only one, unmistakable location of these two space bases within the sphere of influence of the Earth. These locations are at the two Lagrangian points L(1) (between the Earth and the Moon) and L(3) (in the direction opposite to the Moon from the Earth). We show that placing missile bases at L(1) and L(3) would enable those missiles to deflect the trajectory of impactors by hitting them orthogonally to their impact trajectory toward the Earth, so as to maximize their deflection. We show that confocal conics are the best class of trajectories fulfilling this orthogonal deflection requirement. One additional remark is that the theory developed in this paper is just a beginning for a wider set of future research. In fact, we only develop the Keplerian analytical theory for the optimal planetary defense achievable from the Earth-Moon Lagrangian points L(1) and L(3). Much more sophisticated analytical refinements would be needed to: (1) take into account many perturbation forces of all kinds acting on both the impactors and missiles shot from L(1) and L(3); (2) add more (non-optimal) trajectories of missiles shot from either the Lagrangian points L(4) and L(5) of the Earth-Moon System or from the surface of the Moon itself; and (3) encompass the full range of missiles currently available to the US (and possibly other countries) so as to really see which impactors could be diverted by which missiles, even in the very simplified scheme outlined here. Published for the first time in February 2002, our Keplerian planetary defense theory has proved, in just one year, to be simple enough to catch the attention of scholars, in addition to popular writers, and even of someone from the US Military. These recent developments might possibly mark the beginning of an all embracing vision in planetary defense beyond all learned congressional activities, dramatic movies, and unknown military plans covered by secrecy.

  17. The Cerebro-oculo-facio-skeletal Syndrome Point Mutation F231L in the ERCC1 DNA Repair Protein Causes Dissociation of the ERCC1-XPF Complex.

    PubMed

    Faridounnia, Maryam; Wienk, Hans; Kovačič, Lidija; Folkers, Gert E; Jaspers, Nicolaas G J; Kaptein, Robert; Hoeijmakers, Jan H J; Boelens, Rolf

    2015-08-14

    The ERCC1-XPF heterodimer, a structure-specific DNA endonuclease, is best known for its function in the nucleotide excision repair (NER) pathway. The ERCC1 point mutation F231L, located at the hydrophobic interaction interface of ERCC1 (excision repair cross-complementation group 1) and XPF (xeroderma pigmentosum complementation group F), leads to severe NER pathway deficiencies. Here, we analyze biophysical properties and report the NMR structure of the complex of the C-terminal tandem helix-hairpin-helix domains of ERCC1-XPF that contains this mutation. The structures of wild type and the F231L mutant are very similar. The F231L mutation results in only a small disturbance of the ERCC1-XPF interface, where, in contrast to Phe(231), Leu(231) lacks interactions stabilizing the ERCC1-XPF complex. One of the two anchor points is severely distorted, and this results in a more dynamic complex, causing reduced stability and an increased dissociation rate of the mutant complex as compared with wild type. These data provide a biophysical explanation for the severe NER deficiencies caused by this mutation. © 2015 by The American Society for Biochemistry and Molecular Biology, Inc.

  18. Determining Optimal Waste Volume From an Intravenous Catheter

    PubMed Central

    Baker, Rachel B.; Summer, Suzanne S.; Lawrence, Michelle; Shova, Amy; McGraw, Catherine A.; Khoury, Jane

    2013-01-01

    Waste is blood drawn from an intravenous (IV) catheter to remove saline before obtaining a blood sample. This study examines the minimum waste volume resulting in an undiluted sample. A repeated measures design was used. Investigators placed an IV catheter in 60 healthy adults and obtained samples at baseline and following waste volume ranging from 0.5 mL to 3 mL. A random effects mixed model was used to determine the stabilizing point. For sodium and glucose measurements, this stabilizing point was 1 mL of waste. Knowing that only 1 mL of waste is needed will prevent clinicians from obtaining extra waste and discarding blood needlessly. PMID:23455970

  19. Consultation-liaison psychiatry and psychosomatic medicine: the company they keep.

    PubMed

    Lipsitt, D R

    2001-01-01

    The objectives of this review are 1) to briefly describe the parallel historical developments of consultation-liaison (C-L) psychiatry and psychosomatic medicine [corrected]; 2) to analyze the extent to which the literature of C-L psychiatry and psychosomatic medicine relate to each other, given that both fields have evolved simultaneously in the history of psychiatry; and 3) to propose possible explanations for observed publication patterns in selected C-L resources and the journal Psychosomatic Medicine. The quasi-citation analysis includes two segments: 1) a review of selected key C-L psychiatry references to determine the extent to which classic articles from Psychosomatic Medicine are cited; and 2) an analysis of 60 years of Psychosomatic Medicine, sampling issues from the first 5 years of each decade and all issues of the year 2000 for articles of potential relevance to C-L psychiatry. References to Psychosomatic Medicine articles in C-L resources are tallied as percentages of total references in each source. Articles in Psychosomatic Medicine are assigned to one of three categories (A, B, or C) according to their perceived relevance to C-L psychiatry, from most (A) to least (C) relevant. The review of C-L sources ("basic" reading lists and reference lists of seminal articles and textbooks) revealed a wide range of Psychosomatic Medicine citations, from 0% to 27.4% (average, 7.5%). The survey of Psychosomatic Medicine sorted 1705 articles for their relevance to C-L psychiatry into category A (9.5-40.6%, average 21.3%), category B (70.4-86.3%, average 72.3%), and category C (0.7-12.1%, average 6.4%) for each half-decade for the past 60 years. The lowest number of category A articles appeared in the years 1970 to 1975, and the highest number appeared in 1950 to 1955; reciprocal results were found for category B articles. The lowest number of category C articles appeared in 1980 to 1985, and the highest number appeared in 1940 to 1945. For the six issues of 2000, the distributions of articles in categories A, B, and C are similar, continuing an upward trend beginning in 1975 of core (category A) articles. Explanations for publication patterns are speculatively related to various factors, such as a paucity of C-L research and researchers, the broad definition of C-L psychiatry, editorial policies, and the impact of World War II. Although C-L psychiatry and psychosomatic medicine have common roots, the reliance of the C-L literature on classic Psychosomatic Medicine articles has varied markedly, from none to about one-quarter of its references. Nevertheless, Psychosomatic Medicine has consistently published articles of theoretical and clinical interest to C-L psychiatrists, with more than 90% of published articles considered to be of high or moderate relevance to C-L psychiatry. A far higher percentage of articles in Psychosomatic Medicine would seem to be relevant to the field of C-L psychiatry than are cited in significant C-L literature. Psychosomatic Medicine's essential focus on empirical research may dissuade the more clinically oriented C-L psychiatrists.

  20. Change in quality of life and predictors of change among patients with multiple sclerosis: a prospective cohort study.

    PubMed

    Tepavcevic, Darija Kisic; Pekmezovic, Tatjana; Stojsavljevic, Nebojsa; Kostic, Jelena; Basuroski, Irena Dujmovic; Mesaros, Sarlota; Drulovic, Jelena

    2014-04-01

    The aim of this study was to determine the changes in the health-related quality of life (HRQoL) and predictors of change among patients with multiple sclerosis (MS) at 3 and 6 years during the follow-up period. A group of 109 consecutive MS patients (McDonald's criteria) referred to the Clinic of Neurology, Belgrade, were enrolled in the study. At three time points during the study (baseline, and at 3 and 6 years during the follow-up period), the HRQoL (measured by MSQoL-54), Expanded Disability Status Scale, and Hamilton Rating Scale for Depression and Fatigue Severity Scale were assessed. During the study period, 93 patients provided both follow-up assessments. Statistically significant deterioration in the HRQoL at each subsequent time point was detected for all scales of the MSQoL-54 except for the pain and change in health scales. A higher level of education was a significant prognostic factor for a better HRQoL on the cognitive function scale throughout the entire period of observation, while marital status (single, including divorced and widowed) and increased age at the onset of MS had significant predictive values of poorer quality-of-life scores on the overall quality-of-life scale at 6-year follow-up. Higher levels of physical disability and depression at baseline were statistically significant prognostic markers for deterioration in HRQoL for the majority of MSQoL-54 scales during the entire follow-up period. Our study suggests that baseline demographic and clinical characteristics could be applied as prognostic markers of the HRQOL for patients diagnosed with MS.

Top