Resampling methods in Microsoft Excel® for estimating reference intervals
Theodorsson, Elvar
2015-01-01
Computer- intensive resampling/bootstrap methods are feasible when calculating reference intervals from non-Gaussian or small reference samples. Microsoft Excel® in version 2010 or later includes natural functions, which lend themselves well to this purpose including recommended interpolation procedures for estimating 2.5 and 97.5 percentiles. The purpose of this paper is to introduce the reader to resampling estimation techniques in general and in using Microsoft Excel® 2010 for the purpose of estimating reference intervals in particular. Parametric methods are preferable to resampling methods when the distributions of observations in the reference samples is Gaussian or can transformed to that distribution even when the number of reference samples is less than 120. Resampling methods are appropriate when the distribution of data from the reference samples is non-Gaussian and in case the number of reference individuals and corresponding samples are in the order of 40. At least 500-1000 random samples with replacement should be taken from the results of measurement of the reference samples. PMID:26527366
Resampling methods in Microsoft Excel® for estimating reference intervals.
Theodorsson, Elvar
2015-01-01
Computer-intensive resampling/bootstrap methods are feasible when calculating reference intervals from non-Gaussian or small reference samples. Microsoft Excel® in version 2010 or later includes natural functions, which lend themselves well to this purpose including recommended interpolation procedures for estimating 2.5 and 97.5 percentiles. The purpose of this paper is to introduce the reader to resampling estimation techniques in general and in using Microsoft Excel® 2010 for the purpose of estimating reference intervals in particular. Parametric methods are preferable to resampling methods when the distributions of observations in the reference samples is Gaussian or can transformed to that distribution even when the number of reference samples is less than 120. Resampling methods are appropriate when the distribution of data from the reference samples is non-Gaussian and in case the number of reference individuals and corresponding samples are in the order of 40. At least 500-1000 random samples with replacement should be taken from the results of measurement of the reference samples.
Estimation of reference intervals from small samples: an example using canine plasma creatinine.
Geffré, A; Braun, J P; Trumel, C; Concordet, D
2009-12-01
According to international recommendations, reference intervals should be determined from at least 120 reference individuals, which often are impossible to achieve in veterinary clinical pathology, especially for wild animals. When only a small number of reference subjects is available, the possible bias cannot be known and the normality of the distribution cannot be evaluated. A comparison of reference intervals estimated by different methods could be helpful. The purpose of this study was to compare reference limits determined from a large set of canine plasma creatinine reference values, and large subsets of this data, with estimates obtained from small samples selected randomly. Twenty sets each of 120 and 27 samples were randomly selected from a set of 1439 plasma creatinine results obtained from healthy dogs in another study. Reference intervals for the whole sample and for the large samples were determined by a nonparametric method. The estimated reference limits for the small samples were minimum and maximum, mean +/- 2 SD of native and Box-Cox-transformed values, 2.5th and 97.5th percentiles by a robust method on native and Box-Cox-transformed values, and estimates from diagrams of cumulative distribution functions. The whole sample had a heavily skewed distribution, which approached Gaussian after Box-Cox transformation. The reference limits estimated from small samples were highly variable. The closest estimates to the 1439-result reference interval for 27-result subsamples were obtained by both parametric and robust methods after Box-Cox transformation but were grossly erroneous in some cases. For small samples, it is recommended that all values be reported graphically in a dot plot or histogram and that estimates of the reference limits be compared using different methods.
A soil sampling reference site: the challenge in defining reference material for sampling.
de Zorzi, Paolo; Barbizzi, Sabrina; Belli, Maria; Fajgelj, Ales; Jacimovic, Radojko; Jeran, Zvonka; Sansone, Umberto; van der Perk, Marcel
2008-11-01
In the frame of the international SOILSAMP project, funded and coordinated by the Italian Environmental Protection Agency, an agricultural area was established as a reference site suitable for performing soil sampling inter-comparison exercises. The reference site was characterized for trace element content in soil, in terms of the spatial and temporal variability of their mass fraction. Considering that the behaviour of long-lived radionuclides in soil can be expected to be similar to that of some stable trace elements and that the distribution of these trace elements in soil can simulate the distribution of radionuclides, the reference site characterised in term of trace elements, can be also used to compare the soil sampling strategies developed for radionuclide investigations.
Hajeb, Parvaneh; Herrmann, Susan S; Poulsen, Mette E
2017-07-19
The guidance document SANTE 11945/2015 recommends that cereal samples be milled to a particle size preferably smaller than 1.0 mm and that extensive heating of the samples should be avoided. The aim of the present study was therefore to investigate the differences in milling procedures, obtained particle size distributions, and the resulting pesticide residue recovery when cereal samples were milled at the European Union National Reference Laboratories (NRLs) with their routine milling procedures. A total of 23 NRLs participated in the study. The oat and rye samples milled by each NRL were sent to the European Union Reference Laboratory on Cereals and Feedingstuff (EURL) for the determination of the particle size distribution and pesticide residue recovery. The results showed that the NRLs used several different brands and types of mills. Large variations in the particle size distributions and pesticide extraction efficiencies were observed even between samples milled by the same type of mill.
Commutability of food microbiology proficiency testing samples.
Abdelmassih, M; Polet, M; Goffaux, M-J; Planchon, V; Dierick, K; Mahillon, J
2014-03-01
Food microbiology proficiency testing (PT) is a useful tool to assess the analytical performances among laboratories. PT items should be close to routine samples to accurately evaluate the acceptability of the methods. However, most PT providers distribute exclusively artificial samples such as reference materials or irradiated foods. This raises the issue of the suitability of these samples because the equivalence-or 'commutability'-between results obtained on artificial vs. authentic food samples has not been demonstrated. In the clinical field, the use of noncommutable PT samples has led to erroneous evaluation of the performances when different analytical methods were used. This study aimed to provide a first assessment of the commutability of samples distributed in food microbiology PT. REQUASUD and IPH organized 13 food microbiology PTs including 10-28 participants. Three types of PT items were used: genuine food samples, sterile food samples and reference materials. The commutability of the artificial samples (reference material or sterile samples) was assessed by plotting the distribution of the results on natural and artificial PT samples. This comparison highlighted matrix-correlated issues when nonfood matrices, such as reference materials, were used. Artificially inoculated food samples, on the other hand, raised only isolated commutability issues. In the organization of a PT-scheme, authentic or artificially inoculated food samples are necessary to accurately evaluate the analytical performances. Reference materials, used as PT items because of their convenience, may present commutability issues leading to inaccurate penalizing conclusions for methods that would have provided accurate results on food samples. For the first time, the commutability of food microbiology PT samples was investigated. The nature of the samples provided by the organizer turned out to be an important factor because matrix effects can impact on the analytical results. © 2013 The Society for Applied Microbiology.
[Effects of sampling plot number on tree species distribution prediction under climate change].
Liang, Yu; He, Hong-Shi; Wu, Zhi-Wei; Li, Xiao-Na; Luo, Xu
2013-05-01
Based on the neutral landscapes under different degrees of landscape fragmentation, this paper studied the effects of sampling plot number on the prediction of tree species distribution at landscape scale under climate change. The tree species distribution was predicted by the coupled modeling approach which linked an ecosystem process model with a forest landscape model, and three contingent scenarios and one reference scenario of sampling plot numbers were assumed. The differences between the three scenarios and the reference scenario under different degrees of landscape fragmentation were tested. The results indicated that the effects of sampling plot number on the prediction of tree species distribution depended on the tree species life history attributes. For the generalist species, the prediction of their distribution at landscape scale needed more plots. Except for the extreme specialist, landscape fragmentation degree also affected the effects of sampling plot number on the prediction. With the increase of simulation period, the effects of sampling plot number on the prediction of tree species distribution at landscape scale could be changed. For generalist species, more plots are needed for the long-term simulation.
Woodworth, M.T.; Connor, B.F.
2001-01-01
This report presents the results of the U.S. Geological Survey's analytical evaluation program for six standard reference samples -- T-165 (trace constituents), M-158 (major constituents), N-69 (nutrient constituents), N-70 (nutrient constituents), P-36 (low ionic-strength constituents), and Hg-32 (mercury) -- that were distributed in April 2001 to laboratories enrolled in the U.S. Geological Survey sponsored interlaboratory testing program. Analytical data received from 73 laboratories were evaluated with respect to overall laboratory performance and relative laboratory performance for each analyte in the six reference samples. Results of these evaluations are presented in tabular form. Also presented are tables and graphs summarizing the analytical data provided by each laboratory for each analyte in the six standard reference samples. The most probable value for each analyte was determined using nonparametric statistics.
Woodworth, M.T.; Conner, B.F.
2002-01-01
This report presents the results of the U.S. Geological Survey's analytical evaluation program for six standard reference samples -- T- 169 (trace constituents), M- 162 (major constituents), N-73 (nutrient constituents), N-74 (nutrient constituents), P-38 (low ionic-strength constituents), and Hg-34 (mercury) -- that were distributed in March 2002 to laboratories enrolled in the U.S. Geological Survey sponsored intedaboratory testing program. Analytical data received from 93 laboratories were evaluated with respect to overall laboratory performance and relative laboratory performance for each analyte in the six reference samples. Results of these evaluations are presented in tabular form. Also presented are tables and graphs summarizing the analytical data provided by each laboratory for each analyte in the six standard reference samples. The most probable value for each analyte was determined using nonparametric statistics.
Woodworth, Mark T.; Connor, Brooke F.
2003-01-01
This report presents the results of the U.S. Geological Survey's analytical evaluation program for six standard reference samples -- T-171 (trace constituents), M-164 (major constituents), N-75 (nutrient constituents), N-76 (nutrient constituents), P-39 (low ionic-strength constituents), and Hg-35 (mercury) -- that were distributed in September 2002 to laboratories enrolled in the U.S. Geological Survey sponsored interlaboratory testing program. Analytical data received from 102 laboratories were evaluated with respect to overall laboratory performance and relative laboratory performance for each analyte in the six reference samples. Results of these evaluations are presented in tabular form. Also presented are tables and graphs summarizing the analytical data provided by each laboratory for each analyte in the six standard reference samples. The most probable value for each analyte was determined using nonparametric statistics.
Woodworth, Mark T.; Connor, Brooke F.
2002-01-01
This report presents the results of the U.S. Geological Survey's analytical evaluation program for six standard reference samples -- T-167 (trace constituents), M-160 (major constituents), N-71 (nutrient constituents), N-72 (nutrient constituents), P-37 (low ionic-strength constituents), and Hg-33 (mercury) -- that were distributed in September 2001 to laboratories enrolled in the U.S. Geological Survey sponsored interlaboratory testing program. Analytical data received from 98 laboratories were evaluated with respect to overall laboratory performance and relative laboratory performance for each analyte in the six reference samples. Results of these evaluations are presented in tabular form. Also presented are tables and graphs summarizing the analytical data provided by each laboratory for each analyte in the six standard reference samples. The most probable value for each analyte was determined using nonparametric statistics.
Farrar, Jerry W.; Copen, Ashley M.
2000-01-01
This report presents the results of the U.S. Geological Survey's analytical evaluation program for six standard reference samples -- T-161 (trace constituents), M-154 (major constituents), N-65 (nutrient constituents), N-66 nutrient constituents), P-34 (low ionic strength constituents), and Hg-30 (mercury) -- that were distributed in March 2000 to 144 laboratories enrolled in the U.S. Geological Survey sponsored interlaboratory testing program. Analytical data that were received from 132 of the laboratories were evaluated with respect to overall laboratory performance and relative laboratory performance for each analyte in the six reference samples. Results of these evaluations are presented in tabular form. Also presented are tables and graphs summarizing the analytical data provided by each laboratory for each analyte in the six standard reference samples. The most probable value for each analyte was determined using nonparametric statistics.
Farrar, T.W.
2000-01-01
This report presents the results of the U.S. Geological Survey's analytical evaluation program for six standard reference samples -- T-159 (trace constituents), M-152 (major constituents), N-63 (nutrient constituents), N-64 (nutrient constituents), P-33 (low ionic strength constituents), and Hg-29 (mercury) -- that were distributed in October 1999 to 149 laboratories enrolled in the U.S. Geological Survey sponsored interlaboratory testing program. Analytical data that were received from 131 of the laboratories were evaluated with respect to overall laboratory performance and relative laboratory performance for each analyte in the six reference samples. Results of these evaluations are presented in tabular form. Also presented are tables and graphs summarizing the analytical data provided by each laboratory for each analyte in the six standard reference samples. The most probable value for each analyte was determined using nonparametric statistics.
Woodworth, Mark T.; Connor, Brooke F.
2003-01-01
This report presents the results of the U.S. Geological Survey's analytical evaluation program for six standard reference samples -- T-173 (trace constituents), M-166 (major constituents), N-77 (nutrient constituents), N-78 (nutrient constituents), P-40 (low ionic-strength constituents), and Hg-36 (mercury) -- that were distributed in March 2003 to laboratories enrolled in the U.S. Geological Survey sponsored interlaboratory testing program. Analytical data received from 110 laboratories were evaluated with respect to overall laboratory performance and relative laboratory performance for each analyte in the six reference samples. Results of these evaluations are presented in tabular form. Also presented are tables and graphs summarizing the analytical data provided by each laboratory for each analyte in the six standard reference samples. The most probable value for each analyte was determined using nonparametric statistics.
Connor, B.F.; Currier, J.P.; Woodworth, M.T.
2001-01-01
This report presents the results of the U.S. Geological Survey's analytical evaluation program for six standard reference samples -- T-163 (trace constituents), M-156 (major constituents), N-67 (nutrient constituents), N-68 (nutrient constituents), P-35 (low ionic strength constituents), and Hg-31 (mercury) -- that were distributed in October 2000 to 126 laboratories enrolled in the U.S. Geological Survey sponsored interlaboratory testing program. Analytical data that were received from 122 of the laboratories were evaluated with respect to overall laboratory performance and relative laboratory performance for each analyte in the six reference samples. Results of these evaluations are presented in tabular form. Also presented are tables and graphs summarizing the analytical data provided by each laboratory for each analyte in the six standard reference samples. The most probable value for each analyte was determined using nonparametric statistics.
Coplen, T.B.; Qi, H.
2009-01-01
New isotope laboratories can achieve the goal of reporting the same isotopic composition within analytical uncertainty for the same material analysed decades apart by (1) writing their own acceptance testing procedures and putting them into their mass spectrometric or laser-based isotope-ratio equipment procurement contract, (2) requiring a manufacturer to demonstrate acceptable performance using all sample ports provided with the instrumentation, (3) for each medium to be analysed, prepare two local reference materials substantially different in isotopic composition to encompass the range in isotopic composition expected in the laboratory and calibrated them with isotopic reference materials available from the International Atomic Energy Agency (IAEA) or the US National Institute of Standards and Technology (NIST), (4) using the optimum storage containers (for water samples, sealing in glass ampoules that are sterilised after sealing is satisfactory), (5) interspersing among sample unknowns local laboratory isotopic reference materials daily (internationally distributed isotopic reference materials can be ordered at three-year intervals, and can be used for elemental analyser analyses and other analyses that consume less than 1 mg of material) - this process applies to H, C, N, O, and S isotope ratios, (6) calculating isotopic compositions of unknowns by normalising isotopic data to that of local reference materials, which have been calibrated to internationally distributed isotopic reference materials, (7) reporting results on scales normalised to internationally distributed isotopic reference materials (where they are available) and providing to sample submitters the isotopic compositions of internationally distributed isotopic reference materials of the same substance had they been analysed with unknowns, (8) providing an audit trail in the laboratory for analytical results - this trail commonly will be in electronic format and might include a laboratory information management system, (9) making at regular intervals a complete backup of laboratory analytical data (both of samples logged into the laboratory and of mass spectrometric analyses), being sure to store one copy of this backup offsite, and (10) participating in interlaboratory comparison exercises sponsored by the IAEA and other agencies at regular intervals. ?? Taylor & Francis.
Jatautis, Šarūnas; Jankauskas, Rimantas
2018-02-01
Objectives. The present study addresses the following two main questions: a) Is the pattern of skeletal ageing observed in well-known western European reference collections applicable to modern eastern Baltic populations, or are population-specific standards needed? b) What are the consequences for estimating the age-at-death distribution in the target population when differences in the estimates from reference data are not taken into account? Materials and methods. The dataset consists of a modern Lithuanian osteological reference collection, which is the only collection of this type in the eastern Baltic countries (n = 381); and two major western European reference collections, Coimbra (n = 264) and Spitalfields (n = 239). The age-related changes were evaluated using the scoring systems of Suchey-Brooks (Brooks & Suchey 1990) and Lovejoy et al. (1985), and were modelled via regression models for multinomial responses. A controlled experiment based on simulations and the Rostock Manifesto estimation protocol (Wood et al. 2002) was then carried out to assess the effect of using estimates from different reference samples and different regression models on estimates of the age-at-death distribution in the hypothetical target population. Results. The following key results were obtained in this study. a) The morphological alterations in the pubic symphysis were much faster among women than among men at comparable ages in all three reference samples. In contrast, we found no strong evidence in any of the reference samples that sex is an important factor to explain rate of changes in the auricular surface. b) The rate of ageing in the pubic symphysis seems to be similar across the three reference samples, but there is little evidence of a similar pattern in the auricular surface. That is, the estimated rate of age-related changes in the auricular surface was much faster in the LORC and the Coimbra samples than in the Spitalfields sample. c) The results of simulations showed that the differences in the estimates from the reference data result in noticeably different age-at-death distributions in the target population. Thus, a degree bias may be expected if estimates from the western European reference data are used to collect information on ages at death in the eastern Baltic region based on the changes in the auricular surface. d) Moreover, the bias is expected to be more pronounced if the fitted regression model improperly describes the reference data. Conclusions. Differences in the timing of age-related changes in skeletal traits are to be expected among European reference samples, and cannot be ignored when seeking to reliably estimate an age-at-death distribution in the target population. This form of bias should be taken into consideration in further studies of skeletal samples from the eastern Baltic region.
Comparison of z-known GRBs with the Main Groups of Bright BATSE Events
NASA Technical Reports Server (NTRS)
Mitrofanov, Igor G.; Sanin, Anton B.; Anfimov, Dmitrij S.; Litvak, Maxim L.; Briggs, Michael S.; Paciesas, William S.; Pendleton, Geoffrey N.; Preece, Robert D.; Meegan, Charles A.; Whitaker, Ann F. (Technical Monitor)
2001-01-01
The small reference sample of six BATSE gamma-ray bursts with known redshifts from optical afterglows is compared with a comparison group of the 218 brightest BATSE bursts. These two groups are shown to be consistent both with respect to the distributions of the spectral peak parameter in the observer's frame and also with respect to the distributions of the frame-independent cosmological invariant parameter (CIP). Using the known values of the redshifts z for the reference sample, the rest-frame distribution of spectral parameters is built. The de-redshifted distribution of the spectral parameters of the reference sample is compared with distribution of these parameters for the comparison group after de-redshifting by the factor 1/(1+z), with z a free parameter. Requiring consistency between these two distributions produces a collective estimation of the best fitting redshifts z for the comparison group, z=1.8--3.6. These values can be considered as the average cosmological redshift of the sources of the brightest BATSE bursts. The most probable value of the peak energy of the spectrum in the rest frame is 920 keV, close to the rest mass of an electron-positron pair.
Jeffrey H. Gove
2003-01-01
Many of the most popular sampling schemes used in forestry are probability proportional to size methods. These methods are also referred to as size biased because sampling is actually from a weighted form of the underlying population distribution. Length- and area-biased sampling are special cases of size-biased sampling where the probability weighting comes from a...
Farrar, Jerry W.; Long, H. Keith
1996-01-01
This report presents the results of the U.S. Geological Survey's analytical evaluation program for 6 standard reference samples--T-137 (trace constituents), M-136 (major constituents), N-47 (nutrient constituents), N-48 (nutrient constituents), P-25 (low ionic strength constituents), and Hg-21 (mercury)--that were distributed in October 1995 to 149 laboratories registered in the U.S. Geological Survey sponsored interlaboratory testing program. Analytical data that were received from 136 of the laboratories were evaluated with respect to: overall laboratory performance and relative laboratory performance for each analyte in the six reference samples. Results of these evaluations are presented in tabular form. Also presented are tables and graphs summarizing the analytical data provided by each laboratory for each analyte in the six standard reference samples. The most probable value for each analyte was determined using nonparametric statistics.
Long, H. Keith; Farrar, Jerry W.
1994-01-01
This report presents the results of the U.S. Geological Survey's analytical evaluation program for five standard reference samples--T-129 (trace constituents), M-130 (major constituents), N-42 (nutrients), P-22 (low ionic strength), Hg-18(mercury),--that were distributed in April 1994 to 157 laboratories registered in the U.S. Geological Survey sponsored interlaboratory testing program. Analytical data that were received from 133 of the laboratories were evaluated with respect to: overall laboratory performance and relative laboratory performance for each analyte in the five reference samples. Results of these evaluations are presented in tabular form. Also presented are tables and graphs summarizing the analytical data provided by each laboratory for each analyte in the five standard reference samples. The most probable value for each analyte was determined using nonparametric statistics.
Long, H.K.; Farrar, J.W.
1993-01-01
This report presents the results of the U.S. Geological Survey's analytical evaluation program for seven standard reference samples--T-123 (trace constituents), T-125 (trace constituents), M-126 (major constituents), N-38 (nutrients), N-39 (Nutrients), P-20 (precipitation-low ionic strength), and Hg-16 (mercury)--that were distributed in April 1993 to 175 laboratories registered in the U.S. Geological Survey sponsored interlaboratory testing program. Analytical data received from 131 of the laboratories were evaluated with respect to: overall laboratory performance and relative laboratory performance for each analyte in the 7 reference samples. Results of these evaluations are presented in tabular form. Also presented are tables and graphs summarizing the analytical data provided by each laboratory for each analyte in the seven standard reference samples. The most probable value for each analyte was determined using nonparametric statistics.
Farrar, Jerry W.; Chleboun, Kimberly M.
1999-01-01
This report presents the results of the U.S. Geological Survey's analytical evaluation program for 8 standard reference samples -- T-157 (trace constituents), M-150 (major constituents), N-61 (nutrient constituents), N-62 (nutrient constituents), P-32 (low ionic strength constituents), GWT-5 (ground-water trace constituents), GWM- 4 (ground-water major constituents),and Hg-28 (mercury) -- that were distributed in March 1999 to 120 laboratories enrolled in the U.S. Geological Survey sponsored interlaboratory testing program. Analytical data that were received from 111 of the laboratories were evaluated with respect to overall laboratory performance and relative laboratory performance for each analyte in the seven reference samples. Results of these evaluations are presented in tabular form. Also presented are tables and graphs summarizing the analytical data provided by each laboratory for each analyte in the 8 standard reference samples. The most probable value for each analyte was determined using nonparametric statistics.
Long, H. Keith; Farrar, Jerry W.
1995-01-01
This report presents the results of the U.S. Geological Survey's analytical evaluation program for 7 standard reference samples--T-131 (trace constituents), T-133 (trace constituents), M-132 (major constituents), N-43 (nutrients), N-44 (nutrients), P-23 (low ionic strength), and Hg-19 (mercury). The samples were distributed in October 1994 to 131 laboratories registered in the U.S. Geological Survey sponsored interlaboratory testing program. Analytical data that were received from 121 of the laboratories were evaluated with respect to: overall laboratory performance and relative laboratory performance for each analyte in the seven reference samples. Results of these evaluations are presented in tabular form. Also presented are tables and graphs summarizing the analytical data provided by each laboratory for each analyte in the seven standard reference samples. The most probable value for each analyte was determined using nonparametric statistics.
Perthold, Jan Walther; Oostenbrink, Chris
2018-05-17
Enveloping distribution sampling (EDS) is an efficient approach to calculate multiple free-energy differences from a single molecular dynamics (MD) simulation. However, the construction of an appropriate reference-state Hamiltonian that samples all states efficiently is not straightforward. We propose a novel approach for the construction of the EDS reference-state Hamiltonian, related to a previously described procedure to smoothen energy landscapes. In contrast to previously suggested EDS approaches, our reference-state Hamiltonian preserves local energy minima of the combined end-states. Moreover, we propose an intuitive, robust and efficient parameter optimization scheme to tune EDS Hamiltonian parameters. We demonstrate the proposed method with established and novel test systems and conclude that our approach allows for the automated calculation of multiple free-energy differences from a single simulation. Accelerated EDS promises to be a robust and user-friendly method to compute free-energy differences based on solid statistical mechanics.
Boulyga, Sergei F; Heumann, Klaus G
2005-10-01
Laser ablation inductively coupled plasma isotope dilution mass spectrometry (LA-ICP-IDMS) was applied to the direct and simultaneous determination of the platinum group elements (PGEs) Pt, Pd, Ru, and Ir in geological and environmental samples. A special laser ablation system with high ablation rates was used, along with sector field ICP-MS. Special attention was paid to deriving the distributions of PGEs in the pulverized samples. IDMS could not be applied to the (mono-isotopic) Rh, but the similar ablation behavior of Ru and Rh allowed Rh to be simultaneously determined via relative sensitivity coefficients. The laser ablation process produces hardly any oxide ions (which usually cause interference in PGE analysis with liquid sample injection), so the ICP-MS can be run in its low mass resolution but high-sensitivity mode. The detection limits obtained for the geological samples were 0.16 ng g(-1), 0.14 ng g(-1), 0.08 ng g(-1), 0.01 ng g(-1) and 0.06 ng g(-1) for Ru, Rh, Pd, Ir and Pt, respectively. LA-ICP-IDMS was applied to different geological reference materials (TDB-1, WGB-1, UMT-1, WMG-1, SARM-7) and the road dust reference material BCR-723, which are only certified for some of the PGEs. Comparisons with certified values as well as with indicative values from the literature demonstrated the validity of the LA-ICP-IDMS method. The PGE concentrations in subsamples of the road dust reference material correspond to a normal distribution, whereas the distributions in the geological reference materials TDB-1, WGB-1, UMT-1, WMG-1, and SARM-7 are more complex. For example, in the case of Ru, a logarithmic normal distribution best fits the analyzed concentrations in TDB-1 subsamples, whereas a pronounced nugget effect was found for Pt in most geological samples.
Geffré, Anne; Concordet, Didier; Braun, Jean-Pierre; Trumel, Catherine
2011-03-01
International recommendations for determination of reference intervals have been recently updated, especially for small reference sample groups, and use of the robust method and Box-Cox transformation is now recommended. Unfortunately, these methods are not included in most software programs used for data analysis by clinical laboratories. We have created a set of macroinstructions, named Reference Value Advisor, for use in Microsoft Excel to calculate reference limits applying different methods. For any series of data, Reference Value Advisor calculates reference limits (with 90% confidence intervals [CI]) using a nonparametric method when n≥40 and by parametric and robust methods from native and Box-Cox transformed values; tests normality of distributions using the Anderson-Darling test and outliers using Tukey and Dixon-Reed tests; displays the distribution of values in dot plots and histograms and constructs Q-Q plots for visual inspection of normality; and provides minimal guidelines in the form of comments based on international recommendations. The critical steps in determination of reference intervals are correct selection of as many reference individuals as possible and analysis of specimens in controlled preanalytical and analytical conditions. Computing tools cannot compensate for flaws in selection and size of the reference sample group and handling and analysis of samples. However, if those steps are performed properly, Reference Value Advisor, available as freeware at http://www.biostat.envt.fr/spip/spip.php?article63, permits rapid assessment and comparison of results calculated using different methods, including currently unavailable methods. This allows for selection of the most appropriate method, especially as the program provides the CI of limits. It should be useful in veterinary clinical pathology when only small reference sample groups are available. ©2011 American Society for Veterinary Clinical Pathology.
Farrar, Jerry W.
1999-01-01
This report presents the results of the U.S. Geological Survey's analytical evaluation program for seven standard reference samples -- T-155 (trace constituents), M-148 (major constituents), N-59 (nutrient constituents), N-60 (nutrient constituents), P-31 (low ionic strength constituents), GWT-4 (ground-water trace constituents), and Hg- 27 (mercury) -- which were distributed in September 1998 to 162 laboratories enrolled in the U.S. Geological Survey sponsored interlaboratory testing program. Analytical data that were received from 136 of the laboratories were evaluated with respect to overall laboratory performance and relative laboratory performance for each analyte in the seven reference samples. Results of these evaluations are presented in tabular form. Also presented are tables and graphs summarizing the analytical data provided by each laboratory for each analyte in the seven standard reference samples. The most probable value for each analyte was determined using nonparametric statistics.
Long, H.K.; Farrar, J.W.
1994-01-01
This report presents the results of the U.S. Geological Survey's analytical evaluation program for eight standard reference samples--T-127 (trace constituents), M-128 (major constituents), N-40 (nutrients), N-41 (nutrients), P-21 (low ionic strength), Hg-17 (mercury), AMW-3 (acid mine water), and WW-1 (whole water)--that were distributed in October 1993 to 158 laboratories registered in the U.S. Geological Survey sponsored interlaboratory testing program. Analytical data that were received from 145 of the laboratories were evaluated with respect to: overall laboratory performance and relative laboratory performance for each analyte in the eight reference samples. Results of these evaluations are presented in tabular form. Also presented are tables and graphs summarizing the analytical data provided by each laboratory for each analyte in the eight standard reference samples. The most probable value for each analyte was determined using nonparametric statistics.
NASA Technical Reports Server (NTRS)
McCubbin, Francis M.; Zeigler, Ryan A.
2017-01-01
The Astromaterials Acquisition and Curation Office (henceforth referred to herein as NASA Curation Office) at NASA Johnson Space Center (JSC) is responsible for curating all of NASA's extraterrestrial samples. Under the governing document, NASA Policy Directive (NPD) 7100.10F JSC is charged with curation of all extraterrestrial material under NASA control, including future NASA missions. The Directive goes on to define Curation as including documentation, preservation, preparation, and distribution of samples for research, education, and public outreach. Here we briefly describe NASA's astromaterials collections and our ongoing efforts related to enhancing the utility of our current collections as well as our efforts to prepare for future sample return missions. We collectively refer to these efforts as advanced curation.
ERIC Educational Resources Information Center
Quesen, Sarah
2016-01-01
When studying differential item functioning (DIF) with students with disabilities (SWD) focal groups typically suffer from small sample size, whereas the reference group population is usually large. This makes it possible for a researcher to select a sample from the reference population to be similar to the focal group on the ability scale. Doing…
Schwacke, Lori H; Hall, Ailsa J; Townsend, Forrest I; Wells, Randall S; Hansen, Larry J; Hohn, Aleta A; Bossart, Gregory D; Fair, Patricia A; Rowles, Teresa K
2009-08-01
To develop robust reference intervals for hematologic and serum biochemical variables by use of data derived from free-ranging bottlenose dolphins (Tursiops truncatus) and examine potential variation in distributions of clinicopathologic values related to sampling sites' geographic locations. 255 free-ranging bottlenose dolphins. Data from samples collected during multiple bottlenose dolphin capture-release projects conducted at 4 southeastern US coastal locations in 2000 through 2006 were combined to determine reference intervals for 52 clinicopathologic variables. A nonparametric bootstrap approach was applied to estimate 95th percentiles and associated 90% confidence intervals; the need for partitioning by length and sex classes was determined by testing for differences in estimated thresholds with a bootstrap method. When appropriate, quantile regression was used to determine continuous functions for 95th percentiles dependent on length. The proportion of out-of-range samples for all clinicopathologic measurements was examined for each geographic site, and multivariate ANOVA was applied to further explore variation in leukocyte subgroups. A need for partitioning by length and sex classes was indicated for many clinicopathologic variables. For each geographic site, few significant deviations from expected number of out-of-range samples were detected. Although mean leukocyte counts did not vary among sites, differences in the mean counts for leukocyte subgroups were identified. Although differences in the centrality of distributions for some variables were detected, the 95th percentiles estimated from the pooled data were robust and applicable across geographic sites. The derived reference intervals provide critical information for conducting bottlenose dolphin population health studies.
USE OF NATURAL WATERS AS U. S. GEOLOGICAL SURVEY REFERENCE SAMPLES.
Janzer, Victor J.
1985-01-01
The U. S. Geological Survey conducts research and collects hydrologic data relating to the Nation's water resources. Seven types of natural matrix reference water samples are prepared for use in the Survey's quality assurance program. These include samples containing major constituents, trace metals, nutrients, herbicides, insecticides, trace metals in a water and suspended-sediment mixture, and precipitation (snowmelt). To prepare these reference samples, natural water is collected in plastic drums and the sediment is allowed to settle. The water is then filtered, selected constituents are added, and if necessary the water is acidified and sterilized by ultraviolet irradiation before bottling in plastic or glass. These reference samples are distributed twice yearly to more than 100 laboratories for chemical analysis. The most probable values for each constituent are determined by evaluating the data submitted by the laboratories using statistical techniques recommended by ASTM.
Coplen, Tyler B.
2010-01-01
Measurement of the same isotopically homogeneous sample by any laboratory worldwide should yield the same isotopic composition within analytical uncertainty. International distribution of light element isotopic reference materials by the International Atomic Energy Agency and the U.S. National Institute of Standards and Technology enable laboratories to achieve this goal.
Daly, Caitlin H; Higgins, Victoria; Adeli, Khosrow; Grey, Vijay L; Hamid, Jemila S
2017-12-01
To statistically compare and evaluate commonly used methods of estimating reference intervals and to determine which method is best based on characteristics of the distribution of various data sets. Three approaches for estimating reference intervals, i.e. parametric, non-parametric, and robust, were compared with simulated Gaussian and non-Gaussian data. The hierarchy of the performances of each method was examined based on bias and measures of precision. The findings of the simulation study were illustrated through real data sets. In all Gaussian scenarios, the parametric approach provided the least biased and most precise estimates. In non-Gaussian scenarios, no single method provided the least biased and most precise estimates for both limits of a reference interval across all sample sizes, although the non-parametric approach performed the best for most scenarios. The hierarchy of the performances of the three methods was only impacted by sample size and skewness. Differences between reference interval estimates established by the three methods were inflated by variability. Whenever possible, laboratories should attempt to transform data to a Gaussian distribution and use the parametric approach to obtain the most optimal reference intervals. When this is not possible, laboratories should consider sample size and skewness as factors in their choice of reference interval estimation method. The consequences of false positives or false negatives may also serve as factors in this decision. Copyright © 2017 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
Adeli, Khosrow; Higgins, Victoria; Nieuwesteeg, Michelle; Raizman, Joshua E; Chen, Yunqi; Wong, Suzy L; Blais, David
2015-08-01
Defining laboratory biomarker reference values in a healthy population and understanding the fluctuations in biomarker concentrations throughout life and between sexes are critical to clinical interpretation of laboratory test results in different disease states. The Canadian Health Measures Survey (CHMS) has collected blood samples and health information from the Canadian household population. In collaboration with the Canadian Laboratory Initiative on Pediatric Reference Intervals (CALIPER), the data have been analyzed to determine reference value distributions and reference intervals for several endocrine and special chemistry biomarkers in pediatric, adult, and geriatric age groups. CHMS collected data and blood samples from thousands of community participants aged 3 to 79 years. We used serum samples to measure 13 immunoassay-based special chemistry and endocrine markers. We assessed reference value distributions and, after excluding outliers, calculated age- and sex-specific reference intervals, along with corresponding 90% CIs, according to CLSI C28-A3 guidelines. We observed fluctuations in biomarker reference values across the pediatric, adult, and geriatric age range, with stratification required on the basis of age for all analytes. Additional sex partitions were required for apolipoprotein AI, homocysteine, ferritin, and high sensitivity C-reactive protein. The unique collaboration between CALIPER and CHMS has enabled, for the first time, a detailed examination of the changes in various immunochemical markers that occur in healthy individuals of different ages. The robust age- and sex-specific reference intervals established in this study provide insight into the complex biological changes that take place throughout development and aging and will contribute to improved clinical test interpretation. © 2015 American Association for Clinical Chemistry.
Jongenburger, I; Reij, M W; Boer, E P J; Gorris, L G M; Zwietering, M H
2011-11-15
The actual spatial distribution of microorganisms within a batch of food influences the results of sampling for microbiological testing when this distribution is non-homogeneous. In the case of pathogens being non-homogeneously distributed, it markedly influences public health risk. This study investigated the spatial distribution of Cronobacter spp. in powdered infant formula (PIF) on industrial batch-scale for both a recalled batch as well a reference batch. Additionally, local spatial occurrence of clusters of Cronobacter cells was assessed, as well as the performance of typical sampling strategies to determine the presence of the microorganisms. The concentration of Cronobacter spp. was assessed in the course of the filling time of each batch, by taking samples of 333 g using the most probable number (MPN) enrichment technique. The occurrence of clusters of Cronobacter spp. cells was investigated by plate counting. From the recalled batch, 415 MPN samples were drawn. The expected heterogeneous distribution of Cronobacter spp. could be quantified from these samples, which showed no detectable level (detection limit of -2.52 log CFU/g) in 58% of samples, whilst in the remainder concentrations were found to be between -2.52 and 2.75 log CFU/g. The estimated average concentration in the recalled batch was -2.78 log CFU/g and a standard deviation of 1.10 log CFU/g. The estimated average concentration in the reference batch was -4.41 log CFU/g, with 99% of the 93 samples being below the detection limit. In the recalled batch, clusters of cells occurred sporadically in 8 out of 2290 samples of 1g taken. The two largest clusters contained 123 (2.09 log CFU/g) and 560 (2.75 log CFU/g) cells. Various sampling strategies were evaluated for the recalled batch. Taking more and smaller samples and keeping the total sampling weight constant, considerably improved the performance of the sampling plans to detect such a type of contaminated batch. Compared to random sampling, stratified random sampling improved the probability to detect the heterogeneous contamination. Copyright © 2011 Elsevier B.V. All rights reserved.
Luchko, Tyler; Blinov, Nikolay; Limon, Garrett C; Joyce, Kevin P; Kovalenko, Andriy
2016-11-01
Implicit solvent methods for classical molecular modeling are frequently used to provide fast, physics-based hydration free energies of macromolecules. Less commonly considered is the transferability of these methods to other solvents. The Statistical Assessment of Modeling of Proteins and Ligands 5 (SAMPL5) distribution coefficient dataset and the accompanying explicit solvent partition coefficient reference calculations provide a direct test of solvent model transferability. Here we use the 3D reference interaction site model (3D-RISM) statistical-mechanical solvation theory, with a well tested water model and a new united atom cyclohexane model, to calculate partition coefficients for the SAMPL5 dataset. The cyclohexane model performed well in training and testing ([Formula: see text] for amino acid neutral side chain analogues) but only if a parameterized solvation free energy correction was used. In contrast, the same protocol, using single solute conformations, performed poorly on the SAMPL5 dataset, obtaining [Formula: see text] compared to the reference partition coefficients, likely due to the much larger solute sizes. Including solute conformational sampling through molecular dynamics coupled with 3D-RISM (MD/3D-RISM) improved agreement with the reference calculation to [Formula: see text]. Since our initial calculations only considered partition coefficients and not distribution coefficients, solute sampling provided little benefit comparing against experiment, where ionized and tautomer states are more important. Applying a simple [Formula: see text] correction improved agreement with experiment from [Formula: see text] to [Formula: see text], despite a small number of outliers. Better agreement is possible by accounting for tautomers and improving the ionization correction.
NASA Astrophysics Data System (ADS)
Luchko, Tyler; Blinov, Nikolay; Limon, Garrett C.; Joyce, Kevin P.; Kovalenko, Andriy
2016-11-01
Implicit solvent methods for classical molecular modeling are frequently used to provide fast, physics-based hydration free energies of macromolecules. Less commonly considered is the transferability of these methods to other solvents. The Statistical Assessment of Modeling of Proteins and Ligands 5 (SAMPL5) distribution coefficient dataset and the accompanying explicit solvent partition coefficient reference calculations provide a direct test of solvent model transferability. Here we use the 3D reference interaction site model (3D-RISM) statistical-mechanical solvation theory, with a well tested water model and a new united atom cyclohexane model, to calculate partition coefficients for the SAMPL5 dataset. The cyclohexane model performed well in training and testing (R=0.98 for amino acid neutral side chain analogues) but only if a parameterized solvation free energy correction was used. In contrast, the same protocol, using single solute conformations, performed poorly on the SAMPL5 dataset, obtaining R=0.73 compared to the reference partition coefficients, likely due to the much larger solute sizes. Including solute conformational sampling through molecular dynamics coupled with 3D-RISM (MD/3D-RISM) improved agreement with the reference calculation to R=0.93. Since our initial calculations only considered partition coefficients and not distribution coefficients, solute sampling provided little benefit comparing against experiment, where ionized and tautomer states are more important. Applying a simple pK_{ {a}} correction improved agreement with experiment from R=0.54 to R=0.66, despite a small number of outliers. Better agreement is possible by accounting for tautomers and improving the ionization correction.
Accounting for Sampling Error in Genetic Eigenvalues Using Random Matrix Theory.
Sztepanacz, Jacqueline L; Blows, Mark W
2017-07-01
The distribution of genetic variance in multivariate phenotypes is characterized by the empirical spectral distribution of the eigenvalues of the genetic covariance matrix. Empirical estimates of genetic eigenvalues from random effects linear models are known to be overdispersed by sampling error, where large eigenvalues are biased upward, and small eigenvalues are biased downward. The overdispersion of the leading eigenvalues of sample covariance matrices have been demonstrated to conform to the Tracy-Widom (TW) distribution. Here we show that genetic eigenvalues estimated using restricted maximum likelihood (REML) in a multivariate random effects model with an unconstrained genetic covariance structure will also conform to the TW distribution after empirical scaling and centering. However, where estimation procedures using either REML or MCMC impose boundary constraints, the resulting genetic eigenvalues tend not be TW distributed. We show how using confidence intervals from sampling distributions of genetic eigenvalues without reference to the TW distribution is insufficient protection against mistaking sampling error as genetic variance, particularly when eigenvalues are small. By scaling such sampling distributions to the appropriate TW distribution, the critical value of the TW statistic can be used to determine if the magnitude of a genetic eigenvalue exceeds the sampling error for each eigenvalue in the spectral distribution of a given genetic covariance matrix. Copyright © 2017 by the Genetics Society of America.
Hosseininasab, Abufazel; Mohammadi, Mohammadreza; Jouzi, Samira; Esmaeilinasab, Maryam; Delavar, Ali
2016-01-01
Objective: This study aimed to provide a normative study documenting how 114 five-seven year-old non-patient Iranian children respond to the Rorschach test. We compared this especial sample to international normative reference values for the Comprehensive System (CS). Method: One hundred fourteen 5- 7- year-old non-patient Iranian children were recruited from public schools. Using five child and adolescent samples from five countries, we compared Iranian Normative Reference Data- based on reference means and standard deviations for each sample. Results: Findings revealed that how the scores in each sample were distributed and how the samples were compared across variables in eight Rorschach Comprehensive System (CS) clusters. We reported all descriptive statistics such as reference mean and standard deviation for all variables. Conclusion: Iranian clinicians could rely on country specific or “local norms” when assessing children. We discourage Iranian clinicians to use many CS scores to make nomothetic, score-based inferences about psychopathology in children and adolescents. PMID:27928247
Han, Xiao; Ge, Miao; Dong, Jie; Xue, Ranying; Wang, Zixuan; He, Jinwei
2014-09-01
The aim of this paper is to analyze the geographical distribution of reference value of aging people's left ventricular end systolic diameter (LVDs), and to provide a scientific basis for clinical examination. The study is focus on the relationship between reference value of left ventricular end systolic diameter of aging people and 14 geographical factors, selecting 2495 samples of left ventricular end systolic diameter (LVDs) of aging people in 71 units of China, in which including 1620 men and 875 women. By using the Moran's I index to make sure the relationship between the reference values and spatial geographical factors, extracting 5 geographical factors which have significant correlation with left ventricular end systolic diameter for building the support vector regression, detecting by the method of paired sample t test to make sure the consistency between predicted and measured values, finally, makes the distribution map through the disjunctive kriging interpolation method and fits the three-dimensional trend of normal reference value. It is found that the correlation between the extracted geographical factors and the reference value of left ventricular end systolic diameter is quite significant, the 5 indexes respectively are latitude, annual mean air temperature, annual mean relative humidity, annual precipitation amount, annual range of air temperature, the predicted values and the observed ones are in good conformity, there is no significant difference at 95% degree of confidence. The overall trend of predicted values increases from west to east, increases first and then decreases from north to south. If geographical values are obtained in one region, the reference value of left ventricular end systolic diameter of aging people in this region can be obtained by using the support vector regression model. It could be more scientific to formulate the different distributions on the basis of synthesizing the physiological and the geographical factors. -Use Moran's index to analyze the spatial correlation. -Choose support vector machine to build model that overcome complexity of variables. -Test normal distribution of predicted data to guarantee the interpolation results. -Through trend analysis to explain the changes of reference value clearly. Copyright © 2014 Elsevier Inc. All rights reserved.
RnaSeqSampleSize: real data based sample size estimation for RNA sequencing.
Zhao, Shilin; Li, Chung-I; Guo, Yan; Sheng, Quanhu; Shyr, Yu
2018-05-30
One of the most important and often neglected components of a successful RNA sequencing (RNA-Seq) experiment is sample size estimation. A few negative binomial model-based methods have been developed to estimate sample size based on the parameters of a single gene. However, thousands of genes are quantified and tested for differential expression simultaneously in RNA-Seq experiments. Thus, additional issues should be carefully addressed, including the false discovery rate for multiple statistic tests, widely distributed read counts and dispersions for different genes. To solve these issues, we developed a sample size and power estimation method named RnaSeqSampleSize, based on the distributions of gene average read counts and dispersions estimated from real RNA-seq data. Datasets from previous, similar experiments such as the Cancer Genome Atlas (TCGA) can be used as a point of reference. Read counts and their dispersions were estimated from the reference's distribution; using that information, we estimated and summarized the power and sample size. RnaSeqSampleSize is implemented in R language and can be installed from Bioconductor website. A user friendly web graphic interface is provided at http://cqs.mc.vanderbilt.edu/shiny/RnaSeqSampleSize/ . RnaSeqSampleSize provides a convenient and powerful way for power and sample size estimation for an RNAseq experiment. It is also equipped with several unique features, including estimation for interested genes or pathway, power curve visualization, and parameter optimization.
Contribution of ants in modifying of soil acidity and particle size distribution
NASA Astrophysics Data System (ADS)
Morgun, Alexandra; Golichenkov, Maxim
2015-04-01
Being a natural body, formed by the influence of biota on the upper layers of the Earth's crust, the soil is the most striking example of biogenic-abiogenic interactions in the biosphere. Invertebrates (especially ants that build soil nests) are important agents that change soil properties in well developed terrestrial ecosystems. Impact of soil microorganisms on soil properties is particularly described in numerous literature and concerns mainly chemical properties and general indicators of soil biological activity. Influence of ants (as representatives of the soil mesofauna) mostly appears as mechanical movement of soil particles and aggregates, and chemical effects caused by concentration of organic matter within the ant's nest. The aim of this research was to evaluate the effect of ants on physical and chemical soil attributes such as particle size distribution and soil acidity. The samples were taken from aerial parts of Lasius niger nests, selected on different elements of the relief (summit position, slope, terrace and floodplain) in the Arkhangelsk region (north of the European part of Russia) and compared with the specimens of the upper horizons of the reference soils. Particle size distribution was determined by laser diffraction method using laser diffraction particle size analyzer «Analysette 22 comfort» (FRITSCH, Germany). The acidity (pH) was determined by potentiometry in water suspension. Particle size distribution of the samples from the nests is more variable as compared to the control samples. For example, the content of 5-10 μm fraction ranges from 9% to 12% in reference soils, while in the anthill samples the variation is from 8% to 15%. Similarly, for 50-250 μm fraction - it ranges from 15% to 18% in reference soils, whereas in anthills - from 6% to 29%. The results of particle size analysis showed that the reference sample on the terrace has silty loam texture and nests soil L. niger are medium loam. The reference soil on the slope is characterized as medium loam, and ant's nest material has silty loam texture. The control samples of soil and ants nests on the summit position are similar and have medium loam texture. Generally we outline that the particle size distribution of anthill samples shows more variability. We assume that ants operate with small soil aggregates, in which fine fractions may link together coarser particles. pH measurements show that the reference soils have a strongly acidic reaction on the summit position (pH 4.6), slightly acidic on the slope (pH 5.5) and neutral on the terrace and on the floodplain (pH 7.2). While the material of the anthills tends to be slightly alkalinized on the summit (pH 4.8) and alkalinized on the slope (pH 7.2), but acidified to neutral on the floodplain and terrace (pH 6.4 and 5.7). Therefore, the ants form specific physico-chemical conditions that are different from the surrounding (native) soil, significantly increasing the complexity of soil cover structure. This is a clear example of ecosystem engineering functions of ants in nature. Increased complexity of soil pattern is the result of variations in pH and particle size distribution. Both cause the preconditions for the formation of new environmental niches and enhance biodiversity in natural ecosystems.
New Ca-Tims and La-Icp Analyses of GJ-1, Plesovice, and FC1 Reference Materials
NASA Astrophysics Data System (ADS)
Feldman, J. D.; Möller, A.; Walker, J. D.
2014-12-01
Laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) U-Pb zircon geochronology relies on external reference standards to monitor and correct for different mass fractionation effects and instrument drift. Common zircon reference materials used within the community, including the KU Isotope Geochemistry Laboratory, are GJ-1 (207Pb/206Pb age: 608.53 +/- 0.37Ma; Jackson et al., 2004), Plesovice (337.13 +/- 0.37 Ma; Slama et al., 2008), and FC-1 (1099.0 +/-0.6 Ma; Paces and Miller, 1993). The age distribution of zircon reference material varies slightly from sample fraction to sample fraction, and the published results for GJ-1 are slightly discordant. As a result, using the published data for the distributed standard splits can lead to small systematic variations when comparing datasets from different labs, and more high precision data are needed to evaluate potential inhomogeneity of sample splits used in different laboratories. Here we characterize these reference materials with cathodoluminescence, LA-ICP-MS traverses across grains, and high precision CA-TIMS to better constrain the ages and assess zoning of these standards, and present the data for comparison with other laboratories. Reducing systematic error by dating our own reference material lends confidence to our analyses and allows for inter-laboratory age reproducibility of unknowns. Additionally, the reduction in propagated uncertainties (especially in GJ-1, for which both the red and yellow variety will be analyzed) will be used to improve long-term reproducibility, comparisons between samples of similar age, detrital populations and composite pluton zircons. Jackson, S.E., et al., 2004, Chemical Geology, v. 211, p. 47-69. Paces, J.B. & Miller, J.D., 1993, Journal of Geophysical Research, v. 80, p. 13997-14013. Slama, J., et al., 2008, Chemical Geology, v. 249. p. 1-35.
A Typology of Antipassives, with Special Reference to Mayan
ERIC Educational Resources Information Center
Heaton, Raina
2017-01-01
This dissertation presents the results of a typological study that investigated the global distribution of antipassive constructions, as well as the distribution of the relevant antipassiverelated features. The sample includes data from 445 languages, which represent 144 language families and isolates. This larger study is informed by an in-depth…
Liu, Jie; Milne, Richard I; Möller, Michael; Zhu, Guang-Fu; Ye, Lin-Jiang; Luo, Ya-Huang; Yang, Jun-Bo; Wambulwa, Moses C; Wang, Chun-Neng; Li, De-Zhu; Gao, Lian-Ming
2018-05-22
Rapid and accurate identification of endangered species is a critical component of biosurveillance and conservation management, and potentially policing illegal trades. However, this is often not possible using traditional taxonomy, especially where only small or preprocessed parts of plants are available. Reliable identification can be achieved via a comprehensive DNA barcode reference library, accompanied by precise distribution data. However, these require extensive sampling at spatial and taxonomic scales, which has rarely been achieved for cosmopolitan taxa. Here, we construct a comprehensive DNA barcode reference library and generate distribution maps using species distribution modelling (SDM), for all 15 Taxus species worldwide. We find that trnL-trnF is the ideal barcode for Taxus: It can distinguish all Taxus species and in combination with ITS identify hybrids. Among five analysis methods tested, NJ was the most effective. Among 4,151 individuals screened for trnL-trnF, 73 haplotypes were detected, all species-specific and some population private. Taxonomical, geographical and genetic dimensions of sampling strategy were all found to affect the comprehensiveness of the resulting DNA barcode library. Maps from SDM showed that most species had allopatric distributions, except T. mairei in the Sino-Himalayan region. Using the barcode library and distribution map data, two unknown forensic samples were identified to species (and in one case, population) level and another was determined as a putative interspecific hybrid. This integrated species identification system for Taxus can be used for biosurveillance, conservation management and to monitor and prosecute illegal trade. Similar identification systems are recommended for other IUCN- and CITES-listed taxa. © 2018 John Wiley & Sons Ltd.
Kulaga, Zbigniew; Litwin, Mieczysław; Tkaczyk, Marcin; Rózdzyńska, Agnieszka; Barwicka, Katarzyna; Grajda, Aneta; Swiader, Anna; Gurzkowska, Beata; Napieralska, Ewelina; Pan, Huiqi
2010-03-04
The growth of children is an indicator of health and society's wellbeing. Growth references are useful in monitoring a child's growth, which is a very important part of child care. Poland's growth references are not updated regularly. Although several growth reference ranges have been developed in Poland over recent years, sampling was restricted to urban populations of major cities. The aim of this study was to assess how well Polish children match with, or diverge from, regional charts and to compare them with international growth references. Four Polish and two international (WHO 2007 and USCDC2000) growth references were used to calculate the height, weight and BMI z-scores in a recent, large, population-representative sample of school-aged children and adolescents in Poland. The distributions of z-scores were analysed with descriptive and inferential statistical methods. Mean height z-scores calculated with the use of the WHO 2007 and USCDC2000 references were positive and significantly different from zero over the entire age range. The mean height z-score was closest to zero in the Poznan reference for boys (0.05) and Warszawa reference for girls (0.01). Median weight z-scores were positive under all weight references over the entire age range with only the exception of 18-year-old girls' weight z-score calculated relative to USCDC2000. Median BMI z-scores were positive in males in early childhood, decreasing with age. In the case of girls, the median BMI z-score calculated using WHO 2007 and USCDC2000 was close to zero in early childhood, decreased in adolescents and reached minimum values at age 18 years. Median BMI z-scores calculated with the use of the Lodz reference fluctuated between 0.05 and 0.2 over the studied age range. In this contemporary sample of Polish school-aged children, distributions of height, weight and BMI differed from those of children from the international growth references. These differences should be considered when using the references. There exist certain limitations to the analysis of height, weight, and BMI z-scores when Polish regional references are used.
2010-01-01
Background The growth of children is an indicator of health and society's wellbeing. Growth references are useful in monitoring a child's growth, which is a very important part of child care. Poland's growth references are not updated regularly. Although several growth reference ranges have been developed in Poland over recent years, sampling was restricted to urban populations of major cities. The aim of this study was to assess how well Polish children match with, or diverge from, regional charts and to compare them with international growth references. Methods Four Polish and two international (WHO 2007 and USCDC2000) growth references were used to calculate the height, weight and BMI z-scores in a recent, large, population-representative sample of school-aged children and adolescents in Poland. The distributions of z-scores were analysed with descriptive and inferential statistical methods. Results Mean height z-scores calculated with the use of the WHO 2007 and USCDC2000 references were positive and significantly different from zero over the entire age range. The mean height z-score was closest to zero in the Poznan reference for boys (0.05) and Warszawa reference for girls (0.01). Median weight z-scores were positive under all weight references over the entire age range with only the exception of 18-year-old girls' weight z-score calculated relative to USCDC2000. Median BMI z-scores were positive in males in early childhood, decreasing with age. In the case of girls, the median BMI z-score calculated using WHO 2007 and USCDC2000 was close to zero in early childhood, decreased in adolescents and reached minimum values at age 18 years. Median BMI z-scores calculated with the use of the Lodz reference fluctuated between 0.05 and 0.2 over the studied age range. Conclusions In this contemporary sample of Polish school-aged children, distributions of height, weight and BMI differed from those of children from the international growth references. These differences should be considered when using the references. There exist certain limitations to the analysis of height, weight, and BMI z-scores when Polish regional references are used. PMID:20199693
The purpose of this SOP is to describe the steps to be taken when field samples are received at Battelle Laboratory for further analysis. The procedure provides for the log-in, initial processing (if required), and distribution of the sample. Procedures concerning the sample Ch...
Experimental and numerical modeling research of rubber material during microwave heating process
NASA Astrophysics Data System (ADS)
Chen, Hailong; Li, Tao; Li, Kunling; Li, Qingling
2018-05-01
This paper aims to investigate the heating behaviors of block rubber by experimental and simulated method. The COMSOL Multiphysics 5.0 software was utilized in numerical simulation work. The effects of microwave frequency, power and sample size on temperature distribution are examined. The effect of frequency on temperature distribution is obvious. The maximum and minimum temperatures of block rubber increase first and then decrease with frequency increasing. The microwave heating efficiency is maximum in the microwave frequency of 2450 MHz. However, more uniform temperature distribution is presented in other microwave frequencies. The influence of microwave power on temperature distribution is also remarkable. The smaller the power, the more uniform the temperature distribution on the block rubber. The effect of power on microwave heating efficiency is not obvious. The effect of sample size on temperature distribution is evidently found. The smaller the sample size, the more uniform the temperature distribution on the block rubber. However, the smaller the sample size, the lower the microwave heating efficiency. The results can serve as references for the research on heating rubber material by microwave technology.
Sidler, Dominik; Schwaninger, Arthur; Riniker, Sereina
2016-10-21
In molecular dynamics (MD) simulations, free-energy differences are often calculated using free energy perturbation or thermodynamic integration (TI) methods. However, both techniques are only suited to calculate free-energy differences between two end states. Enveloping distribution sampling (EDS) presents an attractive alternative that allows to calculate multiple free-energy differences in a single simulation. In EDS, a reference state is simulated which "envelopes" the end states. The challenge of this methodology is the determination of optimal reference-state parameters to ensure equal sampling of all end states. Currently, the automatic determination of the reference-state parameters for multiple end states is an unsolved issue that limits the application of the methodology. To resolve this, we have generalised the replica-exchange EDS (RE-EDS) approach, introduced by Lee et al. [J. Chem. Theory Comput. 10, 2738 (2014)] for constant-pH MD simulations. By exchanging configurations between replicas with different reference-state parameters, the complexity of the parameter-choice problem can be substantially reduced. A new robust scheme to estimate the reference-state parameters from a short initial RE-EDS simulation with default parameters was developed, which allowed the calculation of 36 free-energy differences between nine small-molecule inhibitors of phenylethanolamine N-methyltransferase from a single simulation. The resulting free-energy differences were in excellent agreement with values obtained previously by TI and two-state EDS simulations.
Miller, Michael A; Colby, Alison C C; Kanehl, Paul D; Blocksom, Karen
2009-03-01
The Wisconsin Department of Natural Resources (WDNR), with support from the U.S. EPA, conducted an assessment of wadeable streams in the Driftless Area ecoregion in western Wisconsin using a probabilistic sampling design. This ecoregion encompasses 20% of Wisconsin's land area and contains 8,800 miles of perennial streams. Randomly-selected stream sites (n = 60) equally distributed among stream orders 1-4 were sampled. Watershed land use, riparian and in-stream habitat, water chemistry, macroinvertebrate, and fish assemblage data were collected at each true random site and an associated "modified-random" site on each stream that was accessed via a road crossing nearest to the true random site. Targeted least-disturbed reference sites (n = 22) were also sampled to develop reference conditions for various physical, chemical, and biological measures. Cumulative distribution function plots of various measures collected at the true random sites evaluated with reference condition thresholds, indicate that high proportions of the random sites (and by inference the entire Driftless Area wadeable stream population) show some level of degradation. Study results show no statistically significant differences between the true random and modified-random sample sites for any of the nine physical habitat, 11 water chemistry, seven macroinvertebrate, or eight fish metrics analyzed. In Wisconsin's Driftless Area, 79% of wadeable stream lengths were accessible via road crossings. While further evaluation of the statistical rigor of using a modified-random sampling design is warranted, sampling randomly-selected stream sites accessed via the nearest road crossing may provide a more economical way to apply probabilistic sampling in stream monitoring programs.
Tsybovskii, I S; Veremeichik, V M; Kotova, S A; Kritskaya, S V; Evmenenko, S A; Udina, I G
2017-02-01
For the Republic of Belarus, development of a forensic reference database on the basis of 18 autosomal microsatellites (STR) using a population dataset (N = 1040), “familial” genotypic dataset (N = 2550) obtained from expertise performance of paternity testing, and a dataset of genotypes from a criminal registration database (N = 8756) is described. Population samples studied consist of 80% ethnic Belarusians and 20% individuals of other nationality or of mixed origin (by questionnaire data). Genotypes of 12346 inhabitants of the Republic of Belarus from 118 regional samples studied by 18 autosomal microsatellites are included in the sample: 16 tetranucleotide STR (D2S1338, TPOX, D3S1358, CSF1PO, D5S818, D8S1179, D7S820, THO1, vWA, D13S317, D16S539, D18S51, D19S433, D21S11, F13B, and FGA) and two pentanucleotide STR (Penta D and Penta E). The samples studied are in Hardy–Weinberg equilibrium according to distribution of genotypes by 18 STR. Significant differences were not detected between discrete populations or between samples from various historical ethnographic regions of the Republic of Belarus (Western and Eastern Polesie, Podneprovye, Ponemanye, Poozerye, and Center), which indicates the absence of prominent genetic differentiation. Statistically significant differences between the studied genotypic datasets also were not detected, which made it possible to combine the datasets and consider the total sample as a unified forensic reference database for 18 “criminalistic” STR loci. Differences between reference database of the Republic of Belarus and Russians and Ukrainians by the distribution of the range of autosomal STR also were not detected, corresponding to a close genetic relationship of the three Eastern Slavic nations mediated by common origin and intense mutual migrations. Significant differences by separate STR loci between the reference database of Republic of Belarus and populations of Southern and Western Slavs were observed. The necessity of using original reference database for support of forensic expertise practice in the Republic of Belarus was demonstrated.
NIST High Accuracy Reference Reflectometer-Spectrophotometer
Proctor, James E.; Yvonne Barnes, P.
1996-01-01
A new reflectometer-spectrophotometer has been designed and constructed using state-of-the-art technology to enhance optical properties of materials measurements over the ultraviolet, visible, and near-infrared (UV-Vis-NIR) wavelength range (200 nm to 2500 nm). The instrument, Spectral Tri-function Automated Reference Reflectometer (STARR), is capable of measuring specular and diffuse reflectance, bidirectional reflectance distribution function (BRDF) of diffuse samples, and both diffuse and non-diffuse transmittance. Samples up to 30 cm by 30 cm can be measured. The instrument and its characterization are described. PMID:27805081
Suspended sediment transport under estuarine tidal channel conditions
Sternberg, R.W.; Kranck, K.; Cacchione, D.A.; Drake, D.E.
1988-01-01
A modified version of the GEOPROBE tripod has been used to monitor flow conditions and suspended sediment distribution in the bottom boundary layer of a tidal channel within San Francisco Bay, California. Measurements were made every 15 minutes over three successive tidal cycles. They included mean velocity profiles from four electromagnetic current meters within 1 m of the seabed; mean suspended sediment concentration profiles from seven miniature nephelometers operated within 1 m of the seabed; near-bottom pressure fluctuations; vertical temperature gradient; and bottom photographs. Additionally, suspended sediment was sampled from four levels within 1 m of the seabed three times during each successive flood and ebb cycle. While the instrument was deployed, STD-nephelometer measurements were made throughout the water column, water samples were collected each 1-2 hours, and bottom sediment was sampled at the deployment site. From these measurements, estimates were made of particle settling velocity (ws) from size distributions of the suspended sediment, friction velocity (U*) from the velocity profiles, and reference concentration (Ca) was measured at z = 20 cm. These parameters were used in the suspended sediment distribution equations to evaluate their ability to predict the observed suspended sediment profiles. Three suspended sediment particle conditions were evaluated: (1) individual particle size in the 4-11 ?? (62.5-0.5 ??m) range with the reference concentration Ca at z = 20 cm (C??), (2) individual particle size in the 4-6 ?? size range, flocs representing the 7-11 ?? size range with the reference concentration Ca at z = 20 cm (Cf), and (3) individual particle size in the 4-6 ?? size range, flocs representing the 7-11 ?? size range with the reference concentration predicted as a function of the bed sediment size distribution and the square of the excess shear stress. In addition, computations of particle flux were made in order to show vertical variations in horizontal mass flux for varying flow conditions. ?? 1988.
C-5A Cargo Deck Low-Frequency Vibration Environment
1975-02-01
SAMPLE VIBRATION CALCULATIONS 13 1. Normal Distribution 13 2. Binomial Distribution 15 IV CONCLUSIONS 17 -! V REFERENCES 18 t: FEiCENDIJJ PAGS 2LANKNOT...Calculation for Binomial Distribution 108 (Vertical Acceleration, Right Rear Cargo Deck) xi I. INTRODUCTION The availability of large transport...the end of taxi. These peaks could then be used directly to compile the probability of occurrence of specific values of acceleration using the binomial
ERIC Educational Resources Information Center
Ali, Usama S.; Walker, Michael E.
2014-01-01
Two methods are currently in use at Educational Testing Service (ETS) for equating observed item difficulty statistics. The first method involves the linear equating of item statistics in an observed sample to reference statistics on the same items. The second method, or the item response curve (IRC) method, involves the summation of conditional…
Suspended sediment transport in an estuarine tidal channel within San Francisco Bay, California
Sternberg, R.W.; Cacchione, D.A.; Drake, D.E.; Kranck, K.
1986-01-01
Size distributions of the suspended sediment samples, estimates of particle settling velocity (??s), friction velocity (U*), and reference concentration (Ca) at z = 20 cm were used in the suspended sediment distribution equations to evaluate their ability to predict the observed suspended sediment profiles. Three suspended sediment particle conditions were evaluated: (1) individual particle sizes in the 4-11 ?? (62.5-0.5 ??m) size range with the reference concentration Ca at z = 20 cm (C??); (2) individual particle sizes in the 4-6 ?? size range, flocs representing the 7-11 ?? size range with the reference concentration Ca at z = 20 cm (Cf); and (3) individual particle sizes in the 4-6 ?? size range, flocs representing the 7-11 ?? size range with the reference concentration predicted as a function of the bed sediment size distribution and the square of the excess shear stress. An analysis was also carried out on the sensitivity of the suspended sediment distribution equation to deviations in the primary variables ??s, U*, and Ca. In addition, computations of mass flux were made in order to show vertical variations in mass flux for varying flow conditions. ?? 1986.
Manganese recycling in the United States in 1998
Jones, Thomas S.
2003-01-01
This report presents the results of the U.S. Geological Survey's analytical evaluation program for six standard reference samples -- T-163 (trace constituents), M-156 (major constituents), N-67 (nutrient constituents), N-68 (nutrient constituents), P-35 (low ionic strength constituents), and Hg-31 (mercury) -- that were distributed in October 2000 to 126 laboratories enrolled in the U.S. Geological Survey sponsored interlaboratory testing program. Analytical data that were received from 122 of the laboratories were evaluated with respect to overall laboratory performance and relative laboratory performance for each analyte in the six reference samples. Results of these evaluations are presented in tabular form. Also presented are tables and graphs summarizing the analytical data provided by each laboratory for each analyte in the six standard reference samples. The most probable value for each analyte was determined using nonparametric statistics.
Estimating Sampling Selection Bias in Human Genetics: A Phenomenological Approach
Risso, Davide; Taglioli, Luca; De Iasio, Sergio; Gueresi, Paola; Alfani, Guido; Nelli, Sergio; Rossi, Paolo; Paoli, Giorgio; Tofanelli, Sergio
2015-01-01
This research is the first empirical attempt to calculate the various components of the hidden bias associated with the sampling strategies routinely-used in human genetics, with special reference to surname-based strategies. We reconstructed surname distributions of 26 Italian communities with different demographic features across the last six centuries (years 1447–2001). The degree of overlapping between "reference founding core" distributions and the distributions obtained from sampling the present day communities by probabilistic and selective methods was quantified under different conditions and models. When taking into account only one individual per surname (low kinship model), the average discrepancy was 59.5%, with a peak of 84% by random sampling. When multiple individuals per surname were considered (high kinship model), the discrepancy decreased by 8–30% at the cost of a larger variance. Criteria aimed at maximizing locally-spread patrilineages and long-term residency appeared to be affected by recent gene flows much more than expected. Selection of the more frequent family names following low kinship criteria proved to be a suitable approach only for historically stable communities. In any other case true random sampling, despite its high variance, did not return more biased estimates than other selective methods. Our results indicate that the sampling of individuals bearing historically documented surnames (founders' method) should be applied, especially when studying the male-specific genome, to prevent an over-stratification of ancient and recent genetic components that heavily biases inferences and statistics. PMID:26452043
Estimating Sampling Selection Bias in Human Genetics: A Phenomenological Approach.
Risso, Davide; Taglioli, Luca; De Iasio, Sergio; Gueresi, Paola; Alfani, Guido; Nelli, Sergio; Rossi, Paolo; Paoli, Giorgio; Tofanelli, Sergio
2015-01-01
This research is the first empirical attempt to calculate the various components of the hidden bias associated with the sampling strategies routinely-used in human genetics, with special reference to surname-based strategies. We reconstructed surname distributions of 26 Italian communities with different demographic features across the last six centuries (years 1447-2001). The degree of overlapping between "reference founding core" distributions and the distributions obtained from sampling the present day communities by probabilistic and selective methods was quantified under different conditions and models. When taking into account only one individual per surname (low kinship model), the average discrepancy was 59.5%, with a peak of 84% by random sampling. When multiple individuals per surname were considered (high kinship model), the discrepancy decreased by 8-30% at the cost of a larger variance. Criteria aimed at maximizing locally-spread patrilineages and long-term residency appeared to be affected by recent gene flows much more than expected. Selection of the more frequent family names following low kinship criteria proved to be a suitable approach only for historically stable communities. In any other case true random sampling, despite its high variance, did not return more biased estimates than other selective methods. Our results indicate that the sampling of individuals bearing historically documented surnames (founders' method) should be applied, especially when studying the male-specific genome, to prevent an over-stratification of ancient and recent genetic components that heavily biases inferences and statistics.
[Printed material distributed by pharmaceutical propaganda agents].
Mejía, R; Avalos, A
2001-01-01
Pharmaceutical sales representatives (drug reps) frequently visit 70% to 90% of physicians during their daily clinical practice and many consider the promotional printed material to be a major source of clinical information. We evaluated samples of the promotional printed material distributed to physicians by drug reps in order to determine whether the data contained in the promotional material is correct and supported by references accessible in Argentina. A consecutive sample of all the promotional material distributed by drug reps in the general internal medicine program (Hospital de Clínicas) was collected between March 15 and April 15, 2000. Reprints and monographs were excluded. Clinical information was reviewed by two general internists and compared to information in a major pharmacology textbook and in an electronic medical information program. References cited were reviewed for correct listing and accessibility in any of the four major medical libraries in Buenos Aires. Of the sixty-four pieces of promotional material collected, thirty were randomly selected and evaluated. In twenty one (70%) the therapeutic effect promoted in advertisement appeared in Goodman & Gilman's 9th edition textbook of pharmacology, in the pharmacology section of the Up-to-Date version 8.1 or in both. Only eighteen (60%) of the thirty promotional printed material evaluated had statements supported by cited references. From a total of 131 references cited in promotional materials, sixty (46%) were incorrectly listed according to the International Committee of Medical Journal Editors. These references were inaccessible. Of the 71 references correctly cited, 49 (69%) were not available in any of the four major medical libraries in Buenos Aires and 8 were available in only two of the libraries. Twenty-two references were reviewed, and in twelve of these (54%), the objective of the research study concurred with the statement of the promotional printed material. Adverse reactions, warnings about drug interactions and contraindications were absent from all promotional printed material. It can be concluded that the promotional printed material distributed by the drug reps in Buenos Aires are biased and provide misinformation more often than not. We recommend that practicing physicians routinely disregard promotional printed material as a source of clinical information.
Thorn, Kevin A.; Folan, Daniel W.; MacCarthy, Patrick
1989-01-01
Standard and reference samples of the International Humic Substances Society have been characterized by solution state carbon-13 and hydrogen-1 nuclear magnetic resonance (NMR) spectrometry. Samples included the Suwannee River, soil, and peat standard fulvic and humic acids, the Leonardite standard humic acid, the Nordic aquatic reference fulvic and humic acids, and the Summit Hill soil reference humic acid. Aqueous-solution carbon-13 NMR analyses included the measurement of spin-lattice relaxation times, measurement of nuclear Overhauser enhancement factors, measurement of quantitative carbon distributions, recording of attached proton test spectra, and recording of spectra under nonquantitative conditions. Distortionless enhancement by polarization transfer carbon-13 NMR spectra also were recorded on the Suwannee River fulvic acid in deuterated dimethyl sulfoxide. Hydrogen-1 NMR spectra were recorded on sodium salts of the samples in deuterium oxide. The carbon aromaticities of the samples ranged from 0.24 for the Suwannee River fulvic acid to 0.58 for the Leonardite humic acid.
NASA Technical Reports Server (NTRS)
McCubbin, F. M.; Evans, C. A.; Fries, M. D.; Harrington, A. D.; Regberg, A. B.; Snead, C. J.; Zeigler, R. A.
2017-01-01
The Astromaterials Acquisition and Curation Office (henceforth referred to herein as NASA Curation Office) at NASA Johnson Space Center (JSC) is responsible for curating all of NASA's extraterrestrial samples. Under the governing document, NASA Policy Directive (NPD) 7100.10F JSC is charged with curation of all extraterrestrial material under NASA control, including future NASA missions. The Directive goes on to define Curation as including documentation, preservation, preparation, and distribution of samples for re-search, education, and public outreach. Here we briefly describe NASA's astromaterials collections and our ongoing efforts related to enhancing the utility of our current collections as well as our efforts to prepare for future sample return missions. We collectively refer to these efforts as advanced curation.
Quantification of HCV RNA in Liver Tissue by bDNA Assay.
Dailey, P J; Collins, M L; Urdea, M S; Wilber, J C
1999-01-01
With this statement, Sherlock and Dooley have described two of the three major challenges involved in quantitatively measuring any analyte in tissue samples: the distribution of the analyte in the tissue; and the standard of reference, or denominator, with which to make comparisons between tissue samples. The third challenge for quantitative measurement of an analyte in tissue is to ensure reproducible and quantitative recovery of the analyte on extraction from tissue samples. This chapter describes a method that can be used to measure HCV RNA quantitatively in liver biopsy and tissue samples using the bDNA assay. All three of these challenges-distribution, denominator, and recovery-apply to the measurement of HCV RNA in liver biopsies.
Approximate sample sizes required to estimate length distributions
Miranda, L.E.
2007-01-01
The sample sizes required to estimate fish length were determined by bootstrapping from reference length distributions. Depending on population characteristics and species-specific maximum lengths, 1-cm length-frequency histograms required 375-1,200 fish to estimate within 10% with 80% confidence, 2.5-cm histograms required 150-425 fish, proportional stock density required 75-140 fish, and mean length required 75-160 fish. In general, smaller species, smaller populations, populations with higher mortality, and simpler length statistics required fewer samples. Indices that require low sample sizes may be suitable for monitoring population status, and when large changes in length are evident, additional sampling effort may be allocated to more precisely define length status with more informative estimators. ?? Copyright by the American Fisheries Society 2007.
230Th-234U Model-Ages of Some Uranium Standard Reference Materials
DOE Office of Scientific and Technical Information (OSTI.GOV)
Williams, R W; Gaffney, A M; Kristo, M J
The 'age' of a sample of uranium is an important aspect of a nuclear forensic investigation and of the attribution of the material to its source. To the extent that the sample obeys the standard rules of radiochronometry, then the production ages of even very recent material can be determined using the {sup 230}Th-{sup 234}U chronometer. These standard rules may be summarized as (a) the daughter/parent ratio at time=zero must be known, and (b) there has been no daughter/parent fractionation since production. For most samples of uranium, the 'ages' determined using this chronometer are semantically 'model-ages' because (a) some assumptionmore » of the initial {sup 230}Th content in the sample is required and (b) closed-system behavior is assumed. The uranium standard reference materials originally prepared and distributed by the former US National Bureau of Standards and now distributed by New Brunswick Laboratory as certified reference materials (NBS SRM = NBL CRM) are good candidates for samples where both rules are met. The U isotopic standards have known purification and production dates, and closed-system behavior in the solid form (U{sub 3}O{sub 8}) may be assumed with confidence. We present here {sup 230}Th-{sup 234}U model-ages for several of these standards, determined by isotope dilution mass spectrometry using a multicollector ICP-MS, and compare these ages with their known production history.« less
It’s about This and That: A Description of Anaphoric Expressions in Clinical Text
Wang, Yan; Melton, Genevieve B.; Pakhomov, Serguei
2011-01-01
Although anaphoric expressions are very common in biomedical and clinical documents, little work has been done to systematically characterize their use in clinical text. Samples of ‘it’, ‘this’, and ‘that’ expressions occurring in inpatient clinical notes from four metropolitan hospitals were analyzed using a combination of semi-automated and manual annotation techniques. We developed a rule-based approach to filter potential non-referential expressions. A physician then manually annotated 1000 potential referential instances to determine referent status and the antecedent of each referent expression. A distributional analysis of the three referring expressions in the entire corpus of notes demonstrates a high prevalence of anaphora and large variance in distributions of referential expressions with different notes. Our results confirm that anaphoric expressions are common in clinical texts. Effective co-reference resolution with anaphoric expressions remains an important challenge in medical natural language processing research. PMID:22195211
A new approach to importance sampling for the simulation of false alarms. [in radar systems
NASA Technical Reports Server (NTRS)
Lu, D.; Yao, K.
1987-01-01
In this paper a modified importance sampling technique for improving the convergence of Importance Sampling is given. By using this approach to estimate low false alarm rates in radar simulations, the number of Monte Carlo runs can be reduced significantly. For one-dimensional exponential, Weibull, and Rayleigh distributions, a uniformly minimum variance unbiased estimator is obtained. For Gaussian distribution the estimator in this approach is uniformly better than that of previously known Importance Sampling approach. For a cell averaging system, by combining this technique and group sampling, the reduction of Monte Carlo runs for a reference cell of 20 and false alarm rate of lE-6 is on the order of 170 as compared to the previously known Importance Sampling approach.
Comparison of the bidirectional reflectance distribution function of various surfaces
NASA Astrophysics Data System (ADS)
Fernandez, Rene; Seasholtz, Richard G.; Oberle, Lawrence G.; Kadambi, Jaikrishnan R.
1989-04-01
This paper describes the development and use of a system to measure the bidirectional reflectance distribution function (BRDF) of various surfaces. The BRDF measurements are to be used in the analysis and design of optical measurement systems such as laser anemometers. An Ar-ion laser (514 nm) was the light source. Preliminary results are presented for eight samples: two glossy black paints, two flat black paints, black glass, sand-blasted Al, unworked Al, and a white paint. A BaSO4 white reflectance standard was used as the reference sample throughout the tests.
Molecularly uniform poly(ethylene glycol) certified reference material
NASA Astrophysics Data System (ADS)
Takahashi, Kayori; Matsuyama, Shigetomo; Kinugasa, Shinichi; Ehara, Kensei; Sakurai, Hiromu; Horikawa, Yoshiteru; Kitazawa, Hideaki; Bounoshita, Masao
2015-02-01
A certified reference material (CRM) for poly(ethylene glycol) with no distribution in the degree of polymerization was developed. The degree of polymerization of the CRM was accurately determined to be 23. Supercritical fluid chromatography (SFC) was used to separate the molecularly uniform polymer from a standard commercial sample with wide polydispersity in its degree of polymerization. Through the use of a specific fractionation system coupled with SFC, we are able to obtain samples of poly(ethylene glycol) oligomer with exact degrees of polymerization, as required for a CRM produced by the National Metrology Institute of Japan.
Rigamonti, Ivo E; Brambilla, Carla; Colleoni, Emanuele; Jermini, Mauro; Trivellone, Valeria; Baumgärtner, Johann
2016-04-01
The paper deals with the study of the spatial distribution and the design of sampling plans for estimating nymph densities of the grape leafhopper Scaphoideus titanus Ball in vine plant canopies. In a reference vineyard sampled for model parameterization, leaf samples were repeatedly taken according to a multistage, stratified, random sampling procedure, and data were subjected to an ANOVA. There were no significant differences in density neither among the strata within the vineyard nor between the two strata with basal and apical leaves. The significant differences between densities on trunk and productive shoots led to the adoption of two-stage (leaves and plants) and three-stage (leaves, shoots, and plants) sampling plans for trunk shoots- and productive shoots-inhabiting individuals, respectively. The mean crowding to mean relationship used to analyze the nymphs spatial distribution revealed aggregated distributions. In both the enumerative and the sequential enumerative sampling plans, the number of leaves of trunk shoots, and of leaves and shoots of productive shoots, was kept constant while the number of plants varied. In additional vineyards data were collected and used to test the applicability of the distribution model and the sampling plans. The tests confirmed the applicability 1) of the mean crowding to mean regression model on the plant and leaf stages for representing trunk shoot-inhabiting distributions, and on the plant, shoot, and leaf stages for productive shoot-inhabiting nymphs, 2) of the enumerative sampling plan, and 3) of the sequential enumerative sampling plan. In general, sequential enumerative sampling was more cost efficient than enumerative sampling.
Improved optics for an ultracentrifuge
NASA Technical Reports Server (NTRS)
Miller, C. G.; Stephens, J. B.
1980-01-01
Ultracentrifuge is important tool in study of polymers, biomolecules, and cell structures. In typical ultracentrifuge rotor supports pair of optically matched vials; one contains sample mixed in solvent, and other is reference that contains only solvent. Doubleslit optical system, transverse to rotor, creates interference pattern on photographic plate each time vials pass through optics. Medium in sample vial displaces interference maximums such that shift gives measurement of density distribution along length of sample.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Carlsbad Field Office
The Performance Demonstration Program (PDP) for headspace gases distributes blind audit samples in a gas matrix for analysis of volatile organic compounds (VOCs). Participating measurement facilities (i.e., fixed laboratories, mobile analysis systems, and on-line analytical systems) are located across the United States. Each sample distribution is termed a PDP cycle. These evaluation cycles provide an objective measure of the reliability of measurements performed for transuranic (TRU) waste characterization. The primary documents governing the conduct of the PDP are the Quality Assurance Program Document (QAPD) (DOE/CBFO-94-1012) and the Waste Isolation Pilot Plant (WIPP) Waste Analysis Plan (WAP) contained in the Hazardousmore » Waste Facility Permit (NM4890139088-TSDF) issued by the New Mexico Environment Department (NMED). The WAP requires participation in the PDP; the PDP must comply with the QAPD and the WAP. This plan implements the general requirements of the QAPD and the applicable requirements of the WAP for the Headspace Gas (HSG) PDP. Participating measurement facilities analyze blind audit samples of simulated TRU waste package headspace gases according to the criteria set by this PDP Plan. Blind audit samples (hereafter referred to as PDP samples) are used as an independent means to assess each measurement facility’s compliance with the WAP quality assurance objectives (QAOs). To the extent possible, the concentrations of VOC analytes in the PDP samples encompass the range of concentrations anticipated in actual TRU waste package headspace gas samples. Analyses of headspace gases are required by the WIPP to demonstrate compliance with regulatory requirements. These analyses must be performed by measurement facilities that have demonstrated acceptable performance in this PDP. These analyses are referred to as WIPP analyses and the TRU waste package headspace gas samples on which they are performed are referred to as WIPP samples in this document. Participating measurement facilities must analyze PDP samples using the same procedures used for routine waste characterization analyses of WIPP samples.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Carlsbad Field Office
The Performance Demonstration Program (PDP) for headspace gases distributes sample gases of volatile organic compounds (VOCs) for analysis. Participating measurement facilities (i.e., fixed laboratories, mobile analysis systems, and on-line analytical systems) are located across the United States. Each sample distribution is termed a PDP cycle. These evaluation cycles provide an objective measure of the reliability of measurements performed for transuranic (TRU) waste characterization. The primary documents governing the conduct of the PDP are the Quality Assurance Program Document (QAPD) (DOE/CBFO-94-1012) and the Waste Isolation Pilot Plant (WIPP) Waste Analysis Plan (WAP) contained in the Hazardous Waste Facility Permit (NM4890139088-TSDF) issuedmore » by the New Mexico Environment Department (NMED). The WAP requires participation in the PDP; the PDP must comply with the QAPD and the WAP. This plan implements the general requirements of the QAPD and the applicable requirements of the WAP for the Headspace Gas (HSG) PDP. Participating measurement facilities analyze blind audit samples of simulated TRU waste package headspace gases according to the criteria set by this PDP Plan. Blind audit samples (hereafter referred to as PDP samples) are used as an independent means to assess each measurement facility’s compliance with the WAP quality assurance objectives (QAOs). To the extent possible, the concentrations of VOC analytes in the PDP samples encompass the range of concentrations anticipated in actual TRU waste package headspace gas samples. Analyses of headspace gases are required by the WIPP to demonstrate compliance with regulatory requirements. These analyses must be performed by measurement facilities that have demonstrated acceptable performance in this PDP. These analyses are referred to as WIPP analyses and the TRU waste package headspace gas samples on which they are performed are referred to as WIPP samples in this document. Participating measurement facilities must analyze PDP samples using the same procedures used for routine waste characterization analyses of WIPP samples.« less
Pengra, Bruce; Long, Jordan; Dahal, Devendra; Stehman, Stephen V.; Loveland, Thomas R.
2015-01-01
The methodology for selection, creation, and application of a global remote sensing validation dataset using high resolution commercial satellite data is presented. High resolution data are obtained for a stratified random sample of 500 primary sampling units (5 km × 5 km sample blocks), where the stratification based on Köppen climate classes is used to distribute the sample globally among biomes. The high resolution data are classified to categorical land cover maps using an analyst mediated classification workflow. Our initial application of these data is to evaluate a global 30 m Landsat-derived, continuous field tree cover product. For this application, the categorical reference classification produced at 2 m resolution is converted to percent tree cover per 30 m pixel (secondary sampling unit)for comparison to Landsat-derived estimates of tree cover. We provide example results (based on a subsample of 25 sample blocks in South America) illustrating basic analyses of agreement that can be produced from these reference data. Commercial high resolution data availability and data quality are shown to provide a viable means of validating continuous field tree cover. When completed, the reference classifications for the full sample of 500 blocks will be released for public use.
Köksal, Muammer Osman; Beka, Hayati; Demirci, Mehmet; Kadioglu, Ates; Agacfidan, Ali; Akgül, Baki
2016-01-01
This study was conducted to determine the prevalence and distribution of urogenital Chlamydia trachomatis genotypes in symptomatic male patients who were referred to the clinics of the Istanbul Faculty of Medicine. Of 419 urogenital swabs, 57 samples (13.6 %) were positive for C. trachomatis . Genotype distribution of C. trachomatis -positive samples identified five genetic variants namely genotype E as the most prevalent (36.4 %), followed by genotype G (23.6 %), H (21.8 %), D (16.4 %) and F (1.8 %). We believe that this is the first study on distribution of genotypes of C. trachomatis genital infections in symptomatic men in Istanbul, Turkey.
Soil sampling strategies: evaluation of different approaches.
de Zorzi, Paolo; Barbizzi, Sabrina; Belli, Maria; Mufato, Renzo; Sartori, Giuseppe; Stocchero, Giulia
2008-11-01
The National Environmental Protection Agency of Italy (APAT) performed a soil sampling intercomparison, inviting 14 regional agencies to test their own soil sampling strategies. The intercomparison was carried out at a reference site, previously characterised for metal mass fraction distribution. A wide range of sampling strategies, in terms of sampling patterns, type and number of samples collected, were used to assess the mean mass fraction values of some selected elements. The different strategies led in general to acceptable bias values (D) less than 2sigma, calculated according to ISO 13258. Sampling on arable land was relatively easy, with comparable results between different sampling strategies.
Book review: A new view on the species abundance distribution
DeAngelis, Donald L.
2018-01-01
The sampled relative abundances of species of a taxonomic group, whether birds, trees, or moths, in a natural community at a particular place vary in a way that suggests a consistent underlying pattern, referred to as the species abundance distribution (SAD). Preston [1] conjectured that the numbers of species, plotted as a histogram of logarithmic abundance classes called octaves, seemed to fit a lognormal distribution; that is, the histograms look like normal distributions, although truncated on the left-hand, or low-species-abundance, end. Although other specific curves for the SAD have been proposed in the literature, Preston’s lognormal distribution is widely cited in textbooks and has stimulated attempts at explanation. An important aspect of Preston’s lognormal distribution is the ‘veil line’, a vertical line drawn exactly at the point of the left-hand truncation in the distribution, to the left of which would be species missing from the sample. Dewdney rejects the lognormal conjecture. Instead, starting with the long-recognized fact that the number of species sampled from a community, when plotted as histograms against population abundance, resembles an inverted J, he presents a mathematical description of an alternative that he calls the ‘J distribution’, a hyperbolic density function truncated at both ends. When multiplied by species richness, R, it becomes the SAD of the sample.
Sample Complexity Bounds for Differentially Private Learning
Chaudhuri, Kamalika; Hsu, Daniel
2013-01-01
This work studies the problem of privacy-preserving classification – namely, learning a classifier from sensitive data while preserving the privacy of individuals in the training set. In particular, the learning algorithm is required in this problem to guarantee differential privacy, a very strong notion of privacy that has gained significant attention in recent years. A natural question to ask is: what is the sample requirement of a learning algorithm that guarantees a certain level of privacy and accuracy? We address this question in the context of learning with infinite hypothesis classes when the data is drawn from a continuous distribution. We first show that even for very simple hypothesis classes, any algorithm that uses a finite number of examples and guarantees differential privacy must fail to return an accurate classifier for at least some unlabeled data distributions. This result is unlike the case with either finite hypothesis classes or discrete data domains, in which distribution-free private learning is possible, as previously shown by Kasiviswanathan et al. (2008). We then consider two approaches to differentially private learning that get around this lower bound. The first approach is to use prior knowledge about the unlabeled data distribution in the form of a reference distribution chosen independently of the sensitive data. Given such a reference , we provide an upper bound on the sample requirement that depends (among other things) on a measure of closeness between and the unlabeled data distribution. Our upper bound applies to the non-realizable as well as the realizable case. The second approach is to relax the privacy requirement, by requiring only label-privacy – namely, that the only labels (and not the unlabeled parts of the examples) be considered sensitive information. An upper bound on the sample requirement of learning with label privacy was shown by Chaudhuri et al. (2006); in this work, we show a lower bound. PMID:25285183
Ng, Chaan S.; Hobbs, Brian P.; Wei, Wei; Anderson, Ella F.; Herron, Delise H.; Yao, James C.; Chandler, Adam G.
2014-01-01
Objective To assess the effects of sampling interval (SI) of CT perfusion acquisitions on CT perfusion values in normal liver and liver metastases from neuroendocrine tumors. Methods CT perfusion in 16 patients with neuroendocrine liver metastases were analyzed by distributed parameter modeling to yield tissue blood flow, blood volume, mean transit time, permeability, and hepatic arterial fraction, for tumor and normal liver. CT perfusion values for the reference sampling interval of 0.5s (SI0.5) were compared with those of SI datasets of 1s, 2s, 3s and 4s, using mixed-effects model analyses. Results Increases in SI beyond 1s were associated with significant and increasing departures of CT perfusion parameters from reference values at SI0.5 (p≤0.0009). CT perfusion values deviated from reference with increasing uncertainty with increasing SIs. Findings for normal liver were concordant. Conclusion Increasing SIs beyond 1s yield significantly different CT perfusion parameter values compared to reference values at SI0.5. PMID:25626401
Comparison of the bidirectional reflectance distribution function of various surfaces
NASA Technical Reports Server (NTRS)
Fernandez, Rene; Seasholtz, Richard G.; Oberle, Lawrence G.; Kadambi, Jaikrishnan R.
1988-01-01
Described is the development and use of a system to measure the Bidirectional Reflectance Distribution Function (BRDF) of various surfaces. The BRDF measurements are used in the analysis and design of optical measurement systems, such as laser anemometers. An argon ion laser (514 nm) is the light source. Preliminary results are presented for eight samples: two glossy black paints, two flat black paints, black glass, sand blasted aluminum, unworked aluminum, and a white paint. A BaSO4 white reflectance standard was used as the reference sample throughout the tests. The reflectance characteristics of these surfaces are compared.
Random vs. systematic sampling from administrative databases involving human subjects.
Hagino, C; Lo, R J
1998-09-01
Two sampling techniques, simple random sampling (SRS) and systematic sampling (SS), were compared to determine whether they yield similar and accurate distributions for the following four factors: age, gender, geographic location and years in practice. Any point estimate within 7 yr or 7 percentage points of its reference standard (SRS or the entire data set, i.e., the target population) was considered "acceptably similar" to the reference standard. The sampling frame was from the entire membership database of the Canadian Chiropractic Association. The two sampling methods were tested using eight different sample sizes of n (50, 100, 150, 200, 250, 300, 500, 800). From the profile/characteristics, summaries of four known factors [gender, average age, number (%) of chiropractors in each province and years in practice], between- and within-methods chi 2 tests and unpaired t tests were performed to determine whether any of the differences [descriptively greater than 7% or 7 yr] were also statistically significant. The strengths of the agreements between the provincial distributions were quantified by calculating the percent agreements for each (provincial pairwise-comparison methods). Any percent agreement less than 70% was judged to be unacceptable. Our assessments of the two sampling methods (SRS and SS) for the different sample sizes tested suggest that SRS and SS yielded acceptably similar results. Both methods started to yield "correct" sample profiles at approximately the same sample size (n > 200). SS is not only convenient, it can be recommended for sampling from large databases in which the data are listed without any inherent order biases other than alphabetical listing by surname.
Wenric, Stephane; Sticca, Tiberio; Caberg, Jean-Hubert; Josse, Claire; Fasquelle, Corinne; Herens, Christian; Jamar, Mauricette; Max, Stéphanie; Gothot, André; Caers, Jo; Bours, Vincent
2017-01-01
An increasing number of bioinformatic tools designed to detect CNVs (copy number variants) in tumor samples based on paired exome data where a matched healthy tissue constitutes the reference have been published in the recent years. The idea of using a pool of unrelated healthy DNA as reference has previously been formulated but not thoroughly validated. As of today, the gold standard for CNV calling is still aCGH but there is an increasing interest in detecting CNVs by exome sequencing. We propose to design a metric allowing the comparison of two CNV profiles, independently of the technique used and assessed the validity of using a pool of unrelated healthy DNA instead of a matched healthy tissue as reference in exome-based CNV detection. We compared the CNV profiles obtained with three different approaches (aCGH, exome sequencing with a matched healthy tissue as reference, exome sequencing with a pool of eight unrelated healthy tissue as reference) on three multiple myeloma samples. We show that the usual analyses performed to compare CNV profiles (deletion/amplification ratios and CNV size distribution) lack in precision when confronted with low LRR values, as they only consider the binary status of each CNV. We show that the metric-based distance constitutes a more accurate comparison of two CNV profiles. Based on these analyses, we conclude that a reliable picture of CNV alterations in multiple myeloma samples can be obtained from whole-exome sequencing in the absence of a matched healthy sample. © 2016 WILEY PERIODICALS, INC.
Assessment of international reference materials for isotope-ratio analysis (IUPAC Technical Report)
Brand, Willi A.; Coplen, Tyler B.; Vogl, Jochen; Rosner, Martin; Prohaska, Thomas
2014-01-01
Since the early 1950s, the number of international measurement standards for anchoring stable isotope delta scales has mushroomed from 3 to more than 30, expanding to more than 25 chemical elements. With the development of new instrumentation, along with new and improved measurement procedures for studying naturally occurring isotopic abundance variations in natural and technical samples, the number of internationally distributed, secondary isotopic reference materials with a specified delta value has blossomed in the last six decades to more than 150 materials. More than half of these isotopic reference materials were produced for isotope-delta measurements of seven elements: H, Li, B, C, N, O, and S. The number of isotopic reference materials for other, heavier elements has grown considerably over the last decade. Nevertheless, even primary international measurement standards for isotope-delta measurements are still needed for some elements, including Mg, Fe, Te, Sb, Mo, and Ge. It is recommended that authors publish the delta values of internationally distributed, secondary isotopic reference materials that were used for anchoring their measurement results to the respective primary stable isotope scale.
Petraco, Ricardo; Dehbi, Hakim-Moulay; Howard, James P; Shun-Shin, Matthew J; Sen, Sayan; Nijjer, Sukhjinder S; Mayet, Jamil; Davies, Justin E; Francis, Darrel P
2018-01-01
Diagnostic accuracy is widely accepted by researchers and clinicians as an optimal expression of a test's performance. The aim of this study was to evaluate the effects of disease severity distribution on values of diagnostic accuracy as well as propose a sample-independent methodology to calculate and display accuracy of diagnostic tests. We evaluated the diagnostic relationship between two hypothetical methods to measure serum cholesterol (Chol rapid and Chol gold ) by generating samples with statistical software and (1) keeping the numerical relationship between methods unchanged and (2) changing the distribution of cholesterol values. Metrics of categorical agreement were calculated (accuracy, sensitivity and specificity). Finally, a novel methodology to display and calculate accuracy values was presented (the V-plot of accuracies). No single value of diagnostic accuracy can be used to describe the relationship between tests, as accuracy is a metric heavily affected by the underlying sample distribution. Our novel proposed methodology, the V-plot of accuracies, can be used as a sample-independent measure of a test performance against a reference gold standard.
Stochastic Residual-Error Analysis For Estimating Hydrologic Model Predictive Uncertainty
A hybrid time series-nonparametric sampling approach, referred to herein as semiparametric, is presented for the estimation of model predictive uncertainty. The methodology is a two-step procedure whereby a distributed hydrologic model is first calibrated, then followed by brute ...
Canine and feline hematology reference values for the ADVIA 120 hematology system.
Moritz, Andreas; Fickenscher, Yvonne; Meyer, Karin; Failing, Klaus; Weiss, Douglas J
2004-01-01
The ADVIA 120 is a laser-based hematology analyzer with software applications for animal species. Accurate reference values would be useful for the assessment of new hematologic parameters and for interlaboratory comparisons. The goal of this study was to establish reference intervals for CBC results and new parameters for RBC morphology, reticulocytes, and platelets in healthy dogs and cats using the ADVIA 120 hematology system. The ADVIA 120, with multispecies software (version 1.107-MS), was used to analyze whole blood samples from clinically healthy dogs (n=46) and cats (n=61). Data distribution was determined and reference intervals were calculated as 2.5 to 97.5 percentiles and 25 to 75 percentiles. Most data showed Gaussian or log-normal distribution. The numbers of RBCs falling outside the normocytic-normochromic range were slightly higher in cats than in dogs. Both dogs and cats had reticulocytes with low, medium, and high absorbance. Mean numbers of large platelets and platelet clumps were higher in cats compared with dogs. Reference intervals obtained on the ADVIA 120 provide valuable baseline information for assessing new hematologic parameters and for interlaboratory comparisons. Differences compared with previously published reference values can be attributed largely to differences in methodology.
Ensemble-Biased Metadynamics: A Molecular Simulation Method to Sample Experimental Distributions
Marinelli, Fabrizio; Faraldo-Gómez, José D.
2015-01-01
We introduce an enhanced-sampling method for molecular dynamics (MD) simulations referred to as ensemble-biased metadynamics (EBMetaD). The method biases a conventional MD simulation to sample a molecular ensemble that is consistent with one or more probability distributions known a priori, e.g., experimental intramolecular distance distributions obtained by double electron-electron resonance or other spectroscopic techniques. To this end, EBMetaD adds an adaptive biasing potential throughout the simulation that discourages sampling of configurations inconsistent with the target probability distributions. The bias introduced is the minimum necessary to fulfill the target distributions, i.e., EBMetaD satisfies the maximum-entropy principle. Unlike other methods, EBMetaD does not require multiple simulation replicas or the introduction of Lagrange multipliers, and is therefore computationally efficient and straightforward in practice. We demonstrate the performance and accuracy of the method for a model system as well as for spin-labeled T4 lysozyme in explicit water, and show how EBMetaD reproduces three double electron-electron resonance distance distributions concurrently within a few tens of nanoseconds of simulation time. EBMetaD is integrated in the open-source PLUMED plug-in (www.plumed-code.org), and can be therefore readily used with multiple MD engines. PMID:26083917
Le Boedec, Kevin
2016-12-01
According to international guidelines, parametric methods must be chosen for RI construction when the sample size is small and the distribution is Gaussian. However, normality tests may not be accurate at small sample size. The purpose of the study was to evaluate normality test performance to properly identify samples extracted from a Gaussian population at small sample sizes, and assess the consequences on RI accuracy of applying parametric methods to samples that falsely identified the parent population as Gaussian. Samples of n = 60 and n = 30 values were randomly selected 100 times from simulated Gaussian, lognormal, and asymmetric populations of 10,000 values. The sensitivity and specificity of 4 normality tests were compared. Reference intervals were calculated using 6 different statistical methods from samples that falsely identified the parent population as Gaussian, and their accuracy was compared. Shapiro-Wilk and D'Agostino-Pearson tests were the best performing normality tests. However, their specificity was poor at sample size n = 30 (specificity for P < .05: .51 and .50, respectively). The best significance levels identified when n = 30 were 0.19 for Shapiro-Wilk test and 0.18 for D'Agostino-Pearson test. Using parametric methods on samples extracted from a lognormal population but falsely identified as Gaussian led to clinically relevant inaccuracies. At small sample size, normality tests may lead to erroneous use of parametric methods to build RI. Using nonparametric methods (or alternatively Box-Cox transformation) on all samples regardless of their distribution or adjusting, the significance level of normality tests depending on sample size would limit the risk of constructing inaccurate RI. © 2016 American Society for Veterinary Clinical Pathology.
Eytan, Danny; Goodwin, Andrew J; Greer, Robert; Guerguerian, Anne-Marie; Laussen, Peter C
2017-01-01
Heart rate (HR) and blood pressure (BP) form the basis for monitoring the physiological state of patients. Although norms have been published for healthy and hospitalized children, little is known about their distributions in critically ill children. The objective of this study was to report the distributions of these basic physiological variables in hospitalized critically ill children. Continuous data from bedside monitors were collected and stored at 5-s intervals from 3,677 subjects aged 0-18 years admitted over a period of 30 months to the pediatric and cardiac intensive care units at a large quaternary children's hospital. Approximately 1.13 billion values served to estimate age-specific distributions for these two basic physiological variables: HR and intra-arterial BP. Centile curves were derived from the sample distributions and compared to common reference ranges. Properties such as kurtosis and skewness of these distributions are described. In comparison to previously published reference ranges, we show that children in these settings exhibit markedly higher HRs than their healthy counterparts or children hospitalized on in-patient wards. We also compared commonly used published estimates of hypotension in children (e.g., the PALS guidelines) to the values we derived from critically ill children. This is a first study reporting the distributions of basic physiological variables in children in the pediatric intensive care settings, and the percentiles derived may serve as useful references for bedside clinicians and clinical trials.
Bardid, Farid; Huyben, Floris; Lenoir, Matthieu; Seghers, Jan; De Martelaer, Kristine; Goodway, Jacqueline D; Deconinck, Frederik J A
2016-06-01
This study aimed to understand the fundamental motor skills (FMS) of Belgian children using the process-oriented Test of Gross Motor Development, Second Edition (TGMD-2) and to investigate the suitability of using the United States (USA) test norms in Belgium. FMS were assessed using the TGMD-2. Gender, age and motor performance were examined in 1614 Belgian children aged 3-8 years (52.1% boys) and compared with the US reference sample. More proficient FMS performance was found with increasing age, from 3 to 6 years for locomotor skills and 3 to 7 years for object control skills. Gender differences were observed in object control skills, with boys performing better than girls. In general, Belgian children had lower levels of motor competence than the US reference sample, specifically for object control skills. The score distribution of the Belgian sample was skewed, with 37.4% scoring below average and only 6.9% scoring above average. This study supported the usefulness of the TGMD-2 as a process-oriented instrument to measure gross motor development in early childhood in Belgium. However, it also demonstrated that caution is warranted when using the US reference norms. ©2016 Foundation Acta Paediatrica. Published by John Wiley & Sons Ltd.
Assessing Performance Tradeoffs in Undersea Distributed Sensor Networks
2006-09-01
time. We refer to this process as track - before - detect (see [5] for a description), since the final determination of a target presence is not made until...expressions for probability of successful search and probability of false search for modeling the track - before - detect process. We then describe a numerical...random manner (randomly sampled from a uniform distribution). II. SENSOR NETWORK PERFORMANCE MODELS We model the process of track - before - detect by
Yang, Huixia; Wei, Yumei; Su, Rina; Wang, Chen; Meng, Wenying; Wang, Yongqing; Shang, Lixin; Cai, Zhenyu; Ji, Liping; Wang, Yunfeng; Sun, Ying; Liu, Jiaxiu; Wei, Li; Sun, Yufeng; Zhang, Xueying; Luo, Tianxia; Chen, Haixia; Yu, Lijun
2016-01-01
Objective To use Z-scores to compare different charts of femur length (FL) applied to our population with the aim of identifying the most appropriate chart. Methods A retrospective study was conducted in Beijing. Fifteen hospitals in Beijing were chosen as clusters using a systemic cluster sampling method, in which 15,194 pregnant women delivered from June 20th to November 30th, 2013. The measurements of FL in the second and third trimester were recorded, as well as the last measurement obtained before delivery. Based on the inclusion and exclusion criteria, we identified FL measurements from 19996 ultrasounds from 7194 patients between 11 and 42 weeks gestation. The FL data were then transformed into Z-scores that were calculated using three series of reference equations obtained from three reports: Leung TN, Pang MW et al (2008); Chitty LS, Altman DG et al (1994); and Papageorghiou AT et al (2014). Each Z-score distribution was presented as the mean and standard deviation (SD). Skewness and kurtosis and were compared with the standard normal distribution using the Kolmogorov-Smirnov test. The histogram of their distributions was superimposed on the non-skewed standard normal curve (mean = 0, SD = 1) to provide a direct visual impression. Finally, the sensitivity and specificity of each reference chart for identifying fetuses <5th or >95th percentile (based on the observed distribution of Z-scores) were calculated. The Youden index was also listed. A scatter diagram with the 5th, 50th, and 95th percentile curves calculated from and superimposed on each reference chart was presented to provide a visual impression. Results The three Z-score distribution curves appeared to be normal, but none of them matched the expected standard normal distribution. In our study, the Papageorghiou reference curve provided the best results, with a sensitivity of 100% for identifying fetuses with measurements < 5th and > 95th percentile, and specificities of 99.9% and 81.5%, respectively. Conclusions It is important to choose an appropriate reference curve when defining what is normal. The Papageorghiou reference curve for FL seems to be the best fit for our population. Perhaps it is time to change our reference curve for femur length. PMID:27458922
Lunar Regolith Characterization for Simulant Design and Evaluation using Figure of Merit Algorithms
NASA Technical Reports Server (NTRS)
Schrader, Christian M.; Rickman, Douglas L.; Melemore, Carole A.; Fikes, John C.; Stoeser, Douglas B.; Wentworth, Susan J.; McKay, David S.
2009-01-01
NASA's Marshall Space Flight Center (MSFC), in conjunction with the United States Geological Survey (USGS) and aided by personnel from the Astromaterials Research and Exploration Science group at Johnson Space Center (ARES-JSC), is implementing a new data acquisition strategy to support the development and evaluation of lunar regolith simulants. The first analyses of lunar regolith samples by the simulant group were carried out in early 2008 on samples from Apollo 16 core 64001/64002. The results of these analyses are combined with data compiled from the literature to generate a reference composition and particle size distribution (PSD)) for lunar highlands regolith. In this paper we present the specifics of particle type composition and PSD for this reference composition. Furthermore. we use Figure-of-Merit (FoM) routines to measure the characteristics of a number of lunar regolith simulants against this reference composition. The lunar highlands regolith reference composition and the FoM results are presented to guide simulant producers and simulant users in their research and development processes.
Liu, Mingying; Jiang, Jing; Han, Xiaojiao; Qiao, Guirong; Zhuo, Renying
2014-01-01
Dendrocalamus latiflorus Munro distributes widely in subtropical areas and plays vital roles as valuable natural resources. The transcriptome sequencing for D. latiflorus Munro has been performed and numerous genes especially those predicted to be unique to D. latiflorus Munro were revealed. qRT-PCR has become a feasible approach to uncover gene expression profiling, and the accuracy and reliability of the results obtained depends upon the proper selection of stable reference genes for accurate normalization. Therefore, a set of suitable internal controls should be validated for D. latiflorus Munro. In this report, twelve candidate reference genes were selected and the assessment of gene expression stability was performed in ten tissue samples and four leaf samples from seedlings and anther-regenerated plants of different ploidy. The PCR amplification efficiency was estimated, and the candidate genes were ranked according to their expression stability using three software packages: geNorm, NormFinder and Bestkeeper. GAPDH and EF1α were characterized to be the most stable genes among different tissues or in all the sample pools, while CYP showed low expression stability. RPL3 had the optimal performance among four leaf samples. The application of verified reference genes was illustrated by analyzing ferritin and laccase expression profiles among different experimental sets. The analysis revealed the biological variation in ferritin and laccase transcript expression among the tissues studied and the individual plants. geNorm, NormFinder, and BestKeeper analyses recommended different suitable reference gene(s) for normalization according to the experimental sets. GAPDH and EF1α had the highest expression stability across different tissues and RPL3 for the other sample set. This study emphasizes the importance of validating superior reference genes for qRT-PCR analysis to accurately normalize gene expression of D. latiflorus Munro.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Houser, Kevin W.; Royer, Michael P.; David, Aurelien
A system for evaluating the color rendition of light sources was recently published as IES TM-30-15 IES Method for Evaluating Light Source Color Rendition. The system includes a fidelity index (Rf) to quantify similarity to a reference illuminant, a relative-gamut index (Rg) to quantify saturation relative to a reference illuminant, and a color vector icon that visually presents information about color rendition. The calculation employs CAM02-UCS and uses a newly-developed set of reflectance functions, comprising 99 color evaluation samples (CES). The CES were down-selected from 105,000 real object samples and are uniformly distributed in color space (fairly representing different colors)more » and wavelength space (avoiding artificial increase of color rendition values by selective optimization).« less
French Norms for the Harvard Group Scale of Hypnotic Susceptibility, Form A.
Anlló, Hernán; Becchio, Jean; Sackur, Jérôme
2017-01-01
The authors present French norms for the Harvard Group Scale of Hypnotic Susceptibility, Form A (HGSHS:A). They administered an adapted translation of Shor and Orne's original text (1962) to a group of 126 paid volunteers. Participants also rated their own responses following our translation of Kihlstrom's Scale of Involuntariness (2006). Item pass rates, score distributions, and reliability were calculated and compared with several other reference samples. Analyses show that the present French norms are congruous with the reference samples. Interestingly, the passing rate for some items drops significantly if "entirely voluntary" responses (as identified by Kihlstrom's scale) are scored as "fail." Copies of the translated scales and response booklet are available online.
Pore size distribution and supercritical hydrogen adsorption in activated carbon fibers
NASA Astrophysics Data System (ADS)
Purewal, J. J.; Kabbour, H.; Vajo, J. J.; Ahn, C. C.; Fultz, B.
2009-05-01
Pore size distributions (PSD) and supercritical H2 isotherms have been measured for two activated carbon fiber (ACF) samples. The surface area and the PSD both depend on the degree of activation to which the ACF has been exposed. The low-surface-area ACF has a narrow PSD centered at 0.5 nm, while the high-surface-area ACF has a broad distribution of pore widths between 0.5 and 2 nm. The H2 adsorption enthalpy in the zero-coverage limit depends on the relative abundance of the smallest pores relative to the larger pores. Measurements of the H2 isosteric adsorption enthalpy indicate the presence of energy heterogeneity in both ACF samples. Additional measurements on a microporous, coconut-derived activated carbon are presented for reference.
Pore size distribution and supercritical hydrogen adsorption in activated carbon fibers.
Purewal, J J; Kabbour, H; Vajo, J J; Ahn, C C; Fultz, B
2009-05-20
Pore size distributions (PSD) and supercritical H2 isotherms have been measured for two activated carbon fiber (ACF) samples. The surface area and the PSD both depend on the degree of activation to which the ACF has been exposed. The low-surface-area ACF has a narrow PSD centered at 0.5 nm, while the high-surface-area ACF has a broad distribution of pore widths between 0.5 and 2 nm. The H2 adsorption enthalpy in the zero-coverage limit depends on the relative abundance of the smallest pores relative to the larger pores. Measurements of the H2 isosteric adsorption enthalpy indicate the presence of energy heterogeneity in both ACF samples. Additional measurements on a microporous, coconut-derived activated carbon are presented for reference.
Wang, Lingling; Wang, Yujiao; Jiang, Shichang; Ye, Mingyue; Su, Ping; Xiong, Bo
2016-10-28
Nitrogen-assisted nanoelectrospray emitter (NANE) was developed to achieve accurate mass-to-charge ratio (m/z) measurements with a single monolithic nozzle. Deposition patterns of generated electrosprays from NANE confirmed their wrapped configurations. Additionally, the intensity of the sample ion and its ratio relative to a reference ion was inclined to focus on the central region of the spray; this trend further supported the existence of wrapped configurations. Further, the proposed NANE was fabricated from poly-(dimethylsiloxane) (PDMS) with octadecyltrichlorosilane modification to restrain the dissolution of PDMS monomers. Assist nitrogen flows were introduced to improve the ionization of reference ions. Moreover, the NANE could regulate the distribution of reference ions by microfluidic three dimensional hydrodynamic focusing. By regulating the distribution of reference ions, the ionization depression was reduced to some degree, and an improved sensitivity was accomplished compared with the mixing of sample and reference solutions. Achieved relative errors of m/z were between 0.2-4.5ppm and 5.2-9.2ppm for ten organic molecules and four biological macromolecules, respectively. Acceptable linear ranges were obtained in quantifications for rhodamine B and emamectin benzoate. Finally, the NANE was compatible with broad infusion rates (from 50nLmin -1 to 15μLmin -1 ) and solutions of different compositions (from 100% methanol to 100% water). Considering the comprehensive application of PDMS in microfluidics, the proposed NANE could be used as a compact and monolithic interface to achieve accurate m/z measurements. Copyright © 2016 Elsevier B.V. All rights reserved.
Mechanical Twinning and Microstructures in Experimentally Stressed Quartzite
NASA Astrophysics Data System (ADS)
Minor, A.; Sintubin, M.; Wenk, H. R.; Rybacki, E.
2015-12-01
Since Dauphiné twins in quartz have been identified as a stress-related intracrystalline microstructure, several electron backscatter diffraction (EBSD) studies revealed that Dauphiné twins are present in naturally deformed quartz-bearing rocks in a wide range of tectono-metamorphic conditions. EBSD studies on experimentally stressed quartzite showed that crystals with particular crystallographic orientations contain many Dauphiné twin boundaries, while neighboring crystals with different orientations are largely free of twin boundaries. To understand the relationship between stress direction and orientation of Dauphiné twinned quartz crystals, a detailed EBSD study was performed on experimentally stressed quartzite samples and compared with an undeformed reference sample. We stressed 4 cylindrical samples in triaxial compression in a Paterson type gas deformation apparatus at GFZ Potsdam. Experimental conditions were 300MPa confining pressure, 500°C temperature and axial stresses of 145MPa, 250MPa and 460MPa for about 30 hours, resulting in a minor strain <0.04%. EBSD scans were obtained with a Zeiss Evo scanning electron microscope and TSL software at UC Berkeley. The EBSD maps show that Dauphiné twinning is present in the starting material as well as in experimentally stressed samples. Pole figures of the bulk orientation of the reference sample compared with stressed samples show a significant difference regarding the distribution for the r and z directions. The reference sample shows an indistinct maximum for r and z, whereas the stressed samples show a maximum for r poles and a minimum for z poles in the axial stress direction. EBSD scans of the reference and stressed samples were further analyzed manually to identify the orientations of single grains, which are free of twin boundaries and those, which contain twin boundaries. This analysis aims to quantify the relationship of crystal orientation and stress magnitude to initiate mechanical twinning.
Some connections between importance sampling and enhanced sampling methods in molecular dynamics.
Lie, H C; Quer, J
2017-11-21
In molecular dynamics, enhanced sampling methods enable the collection of better statistics of rare events from a reference or target distribution. We show that a large class of these methods is based on the idea of importance sampling from mathematical statistics. We illustrate this connection by comparing the Hartmann-Schütte method for rare event simulation (J. Stat. Mech. Theor. Exp. 2012, P11004) and the Valsson-Parrinello method of variationally enhanced sampling [Phys. Rev. Lett. 113, 090601 (2014)]. We use this connection in order to discuss how recent results from the Monte Carlo methods literature can guide the development of enhanced sampling methods.
Some connections between importance sampling and enhanced sampling methods in molecular dynamics
NASA Astrophysics Data System (ADS)
Lie, H. C.; Quer, J.
2017-11-01
In molecular dynamics, enhanced sampling methods enable the collection of better statistics of rare events from a reference or target distribution. We show that a large class of these methods is based on the idea of importance sampling from mathematical statistics. We illustrate this connection by comparing the Hartmann-Schütte method for rare event simulation (J. Stat. Mech. Theor. Exp. 2012, P11004) and the Valsson-Parrinello method of variationally enhanced sampling [Phys. Rev. Lett. 113, 090601 (2014)]. We use this connection in order to discuss how recent results from the Monte Carlo methods literature can guide the development of enhanced sampling methods.
Dehbi, Hakim-Moulay; Howard, James P; Shun-Shin, Matthew J; Sen, Sayan; Nijjer, Sukhjinder S; Mayet, Jamil; Davies, Justin E; Francis, Darrel P
2018-01-01
Background Diagnostic accuracy is widely accepted by researchers and clinicians as an optimal expression of a test’s performance. The aim of this study was to evaluate the effects of disease severity distribution on values of diagnostic accuracy as well as propose a sample-independent methodology to calculate and display accuracy of diagnostic tests. Methods and findings We evaluated the diagnostic relationship between two hypothetical methods to measure serum cholesterol (Cholrapid and Cholgold) by generating samples with statistical software and (1) keeping the numerical relationship between methods unchanged and (2) changing the distribution of cholesterol values. Metrics of categorical agreement were calculated (accuracy, sensitivity and specificity). Finally, a novel methodology to display and calculate accuracy values was presented (the V-plot of accuracies). Conclusion No single value of diagnostic accuracy can be used to describe the relationship between tests, as accuracy is a metric heavily affected by the underlying sample distribution. Our novel proposed methodology, the V-plot of accuracies, can be used as a sample-independent measure of a test performance against a reference gold standard. PMID:29387424
Methods are described for measuring changes in atmospheric O2 concentration with emphasis on gas handling procedures. Cryogenically dried air samples are collected in 5 L glass flasks at ambient pressure and analyzed against reference gases derived from high-pressure aluminum tan...
Han, Zong-wei; Huang, Wei; Luo, Yun; Zhang, Chun-di; Qi, Da-cheng
2015-03-01
Taking the soil organic matter in eastern Zhongxiang County, Hubei Province, as a research object, thirteen sample sets from different regions were arranged surrounding the road network, the spatial configuration of which was optimized by the simulated annealing approach. The topographic factors of these thirteen sample sets, including slope, plane curvature, profile curvature, topographic wetness index, stream power index and sediment transport index, were extracted by the terrain analysis. Based on the results of optimization, a multiple linear regression model with topographic factors as independent variables was built. At the same time, a multilayer perception model on the basis of neural network approach was implemented. The comparison between these two models was carried out then. The results revealed that the proposed approach was practicable in optimizing soil sampling scheme. The optimal configuration was capable of gaining soil-landscape knowledge exactly, and the accuracy of optimal configuration was better than that of original samples. This study designed a sampling configuration to study the soil attribute distribution by referring to the spatial layout of road network, historical samples, and digital elevation data, which provided an effective means as well as a theoretical basis for determining the sampling configuration and displaying spatial distribution of soil organic matter with low cost and high efficiency.
Diaz-Rodriguez, Sebastian; Bozada, Samantha M; Phifer, Jeremy R; Paluch, Andrew S
2016-11-01
We present blind predictions using the solubility parameter based method MOSCED submitted for the SAMPL5 challenge on calculating cyclohexane/water distribution coefficients at 298 K. Reference data to parameterize MOSCED was generated with knowledge only of chemical structure by performing solvation free energy calculations using electronic structure calculations in the SMD continuum solvent. To maintain simplicity and use only a single method, we approximate the distribution coefficient with the partition coefficient of the neutral species. Over the final SAMPL5 set of 53 compounds, we achieved an average unsigned error of [Formula: see text] log units (ranking 15 out of 62 entries), the correlation coefficient (R) was [Formula: see text] (ranking 35), and [Formula: see text] of the predictions had the correct sign (ranking 30). While used here to predict cyclohexane/water distribution coefficients at 298 K, MOSCED is broadly applicable, allowing one to predict temperature dependent infinite dilution activity coefficients in any solvent for which parameters exist, and provides a means by which an excess Gibbs free energy model may be parameterized to predict composition dependent phase-equilibrium.
Height in healthy children in low- and middle-income countries: an assessment.
Karra, Mahesh; Subramanian, S V; Fink, Günther
2017-01-01
Despite rapid economic development and reductions in child mortality worldwide, continued high rates of early childhood stunting have put the global applicability of international child-height standards into question. We used population-based survey data to identify children growing up in healthy environments in low- and middle-income countries and compared the height distribution of these children to the height distribution of the reference sample established by the WHO. Height data were extracted from 169 Demographic and Health Surveys (DHSs) that were collected across 63 countries between 1990 and 2014. Children were classified as having grown up in ideal environments if they 1) had access to safe water and sanitation; 2) lived in households with finished floors, a television, and a car; 3) were born to highly educated mothers; 4) were single births; and 5) were delivered in hospitals. We compared the heights of children in ideal environments with those in the WHO reference sample. A total of 878,249 height records were extracted, and 1006 children (0.1%) were classified as having been raised in an ideal home environment. The mean height-for-age z score (HAZ) in this sample was not statistically different from zero (95% CI: -0.039, 0.125). The HAZ SD for the sample was estimated to be 1.3, and 5.3% of children in the sample were classified as being stunted (HAZ <-2). Similar means, SDs, and stunting rates were found when less restrictive definitions of ideal environments were used. The large current gaps in children's heights relative to those of the reference sample likely are not due to innate or genetic differences between children but, rather, reflect children's continued exposure to poverty, a lack of maternal education, and a lack of access to safe water and sanitation across populations. © 2017 American Society for Nutrition.
König, Gerhard; Miller, Benjamin T; Boresch, Stefan; Wu, Xiongwu; Brooks, Bernard R
2012-10-09
One of the key requirements for the accurate calculation of free energy differences is proper sampling of conformational space. Especially in biological applications, molecular dynamics simulations are often confronted with rugged energy surfaces and high energy barriers, leading to insufficient sampling and, in turn, poor convergence of the free energy results. In this work, we address this problem by employing enhanced sampling methods. We explore the possibility of using self-guided Langevin dynamics (SGLD) to speed up the exploration process in free energy simulations. To obtain improved free energy differences from such simulations, it is necessary to account for the effects of the bias due to the guiding forces. We demonstrate how this can be accomplished for the Bennett's acceptance ratio (BAR) and the enveloping distribution sampling (EDS) methods. While BAR is considered among the most efficient methods available for free energy calculations, the EDS method developed by Christ and van Gunsteren is a promising development that reduces the computational costs of free energy calculations by simulating a single reference state. To evaluate the accuracy of both approaches in connection with enhanced sampling, EDS was implemented in CHARMM. For testing, we employ benchmark systems with analytical reference results and the mutation of alanine to serine. We find that SGLD with reweighting can provide accurate results for BAR and EDS where conventional molecular dynamics simulations fail. In addition, we compare the performance of EDS with other free energy methods. We briefly discuss the implications of our results and provide practical guidelines for conducting free energy simulations with SGLD.
Sampling functions for geophysics
NASA Technical Reports Server (NTRS)
Giacaglia, G. E. O.; Lunquist, C. A.
1972-01-01
A set of spherical sampling functions is defined such that they are related to spherical-harmonic functions in the same way that the sampling functions of information theory are related to sine and cosine functions. An orderly distribution of (N + 1) squared sampling points on a sphere is given, for which the (N + 1) squared spherical sampling functions span the same linear manifold as do the spherical-harmonic functions through degree N. The transformations between the spherical sampling functions and the spherical-harmonic functions are given by recurrence relations. The spherical sampling functions of two arguments are extended to three arguments and to nonspherical reference surfaces. Typical applications of this formalism to geophysical topics are sketched.
Ludtke, Amy S.; Woodworth, Mark T.; Marsh, Philip S.
2000-01-01
The U.S. Geological Survey operates a quality-assurance program based on the analyses of reference samples for two laboratories: the National Water Quality Laboratory and the Quality of Water Service Unit. Reference samples that contain selected inorganic, nutrient, and low-level constituents are prepared and submitted to the laboratory as disguised routine samples. The program goal is to estimate precision and bias for as many analytical methods offered by the participating laboratories as possible. Blind reference samples typically are submitted at a rate of 2 to 5 percent of the annual environmental-sample load for each constituent. The samples are distributed to the laboratories throughout the year. The reference samples are subject to the identical laboratory handling, processing, and analytical procedures as those applied to environmental samples and, therefore, have been used as an independent source to verify bias and precision of laboratory analytical methods and ambient water-quality measurements. The results are stored permanently in the National Water Information System and the Blind Sample Project's data base. During water year 1998, 95 analytical procedures were evaluated at the National Water Quality Laboratory and 63 analytical procedures were evaluated at the Quality of Water Service Unit. An overall evaluation of the inorganic and low-level constituent data for water year 1998 indicated 77 of 78 analytical procedures at the National Water Quality Laboratory met the criteria for precision. Silver (dissolved, inductively coupled plasma-mass spectrometry) was determined to be imprecise. Five of 78 analytical procedures showed bias throughout the range of reference samples: chromium (dissolved, inductively coupled plasma-atomic emission spectrometry), dissolved solids (dissolved, gravimetric), lithium (dissolved, inductively coupled plasma-atomic emission spectrometry), silver (dissolved, inductively coupled plasma-mass spectrometry), and zinc (dissolved, inductively coupled plasma-mass spectrometry). At the National Water Quality Laboratory during water year 1998, lack of precision was indicated for 2 of 17 nutrient procedures: ammonia as nitrogen (dissolved, colorimetric) and orthophosphate as phosphorus (dissolved, colorimetric). Bias was indicated throughout the reference sample range for ammonia as nitrogen (dissolved, colorimetric, low level) and nitrate plus nitrite as nitrogen (dissolved, colorimetric, low level). All analytical procedures tested at the Quality of Water Service Unit during water year 1998 met the criteria for precision. One of the 63 analytical procedures indicated a bias throughout the range of reference samples: aluminum (whole-water recoverable, inductively coupled plasma-atomic emission spectrometry, trace).
Mori, Toshifumi; Hamers, Robert J; Pedersen, Joel A; Cui, Qiang
2014-07-17
Motivated by specific applications and the recent work of Gao and co-workers on integrated tempering sampling (ITS), we have developed a novel sampling approach referred to as integrated Hamiltonian sampling (IHS). IHS is straightforward to implement and complementary to existing methods for free energy simulation and enhanced configurational sampling. The method carries out sampling using an effective Hamiltonian constructed by integrating the Boltzmann distributions of a series of Hamiltonians. By judiciously selecting the weights of the different Hamiltonians, one achieves rapid transitions among the energy landscapes that underlie different Hamiltonians and therefore an efficient sampling of important regions of the conformational space. Along this line, IHS shares similar motivations as the enveloping distribution sampling (EDS) approach of van Gunsteren and co-workers, although the ways that distributions of different Hamiltonians are integrated are rather different in IHS and EDS. Specifically, we report efficient ways for determining the weights using a combination of histogram flattening and weighted histogram analysis approaches, which make it straightforward to include many end-state and intermediate Hamiltonians in IHS so as to enhance its flexibility. Using several relatively simple condensed phase examples, we illustrate the implementation and application of IHS as well as potential developments for the near future. The relation of IHS to several related sampling methods such as Hamiltonian replica exchange molecular dynamics and λ-dynamics is also briefly discussed.
A normative inference approach for optimal sample sizes in decisions from experience
Ostwald, Dirk; Starke, Ludger; Hertwig, Ralph
2015-01-01
“Decisions from experience” (DFE) refers to a body of work that emerged in research on behavioral decision making over the last decade. One of the major experimental paradigms employed to study experience-based choice is the “sampling paradigm,” which serves as a model of decision making under limited knowledge about the statistical structure of the world. In this paradigm respondents are presented with two payoff distributions, which, in contrast to standard approaches in behavioral economics, are specified not in terms of explicit outcome-probability information, but by the opportunity to sample outcomes from each distribution without economic consequences. Participants are encouraged to explore the distributions until they feel confident enough to decide from which they would prefer to draw from in a final trial involving real monetary payoffs. One commonly employed measure to characterize the behavior of participants in the sampling paradigm is the sample size, that is, the number of outcome draws which participants choose to obtain from each distribution prior to terminating sampling. A natural question that arises in this context concerns the “optimal” sample size, which could be used as a normative benchmark to evaluate human sampling behavior in DFE. In this theoretical study, we relate the DFE sampling paradigm to the classical statistical decision theoretic literature and, under a probabilistic inference assumption, evaluate optimal sample sizes for DFE. In our treatment we go beyond analytically established results by showing how the classical statistical decision theoretic framework can be used to derive optimal sample sizes under arbitrary, but numerically evaluable, constraints. Finally, we critically evaluate the value of deriving optimal sample sizes under this framework as testable predictions for the experimental study of sampling behavior in DFE. PMID:26441720
Aravena-Román, Max; Harnett, Gerald B.; Riley, Thomas V.; Inglis, Timothy J. J.; Chang, Barbara J.
2011-01-01
Genotypic characterization of 215 Aeromonas strains (143 clinical, 52 environmental, and 20 reference strains) showed that Aeromonas aquariorum (60 strains, 30.4%) was the most frequently isolated species in clinical and water samples and could be misidentified as Aeromonas hydrophila by phenotypic methods. PMID:21697316
Blind prediction of cyclohexane-water distribution coefficients from the SAMPL5 challenge.
Bannan, Caitlin C; Burley, Kalistyn H; Chiu, Michael; Shirts, Michael R; Gilson, Michael K; Mobley, David L
2016-11-01
In the recent SAMPL5 challenge, participants submitted predictions for cyclohexane/water distribution coefficients for a set of 53 small molecules. Distribution coefficients (log D) replace the hydration free energies that were a central part of the past five SAMPL challenges. A wide variety of computational methods were represented by the 76 submissions from 18 participating groups. Here, we analyze submissions by a variety of error metrics and provide details for a number of reference calculations we performed. As in the SAMPL4 challenge, we assessed the ability of participants to evaluate not just their statistical uncertainty, but their model uncertainty-how well they can predict the magnitude of their model or force field error for specific predictions. Unfortunately, this remains an area where prediction and analysis need improvement. In SAMPL4 the top performing submissions achieved a root-mean-squared error (RMSE) around 1.5 kcal/mol. If we anticipate accuracy in log D predictions to be similar to the hydration free energy predictions in SAMPL4, the expected error here would be around 1.54 log units. Only a few submissions had an RMSE below 2.5 log units in their predicted log D values. However, distribution coefficients introduced complexities not present in past SAMPL challenges, including tautomer enumeration, that are likely to be important in predicting biomolecular properties of interest to drug discovery, therefore some decrease in accuracy would be expected. Overall, the SAMPL5 distribution coefficient challenge provided great insight into the importance of modeling a variety of physical effects. We believe these types of measurements will be a promising source of data for future blind challenges, especially in view of the relatively straightforward nature of the experiments and the level of insight provided.
Blind prediction of cyclohexane-water distribution coefficients from the SAMPL5 challenge
Bannan, Caitlin C.; Burley, Kalistyn H.; Chiu, Michael; Shirts, Michael R.; Gilson, Michael K.; Mobley, David L.
2016-01-01
In the recent SAMPL5 challenge, participants submitted predictions for cyclohexane/water distribution coefficients for a set of 53 small molecules. Distribution coefficients (log D) replace the hydration free energies that were a central part of the past five SAMPL challenges. A wide variety of computational methods were represented by the 76 submissions from 18 participating groups. Here, we analyze submissions by a variety of error metrics and provide details for a number of reference calculations we performed. As in the SAMPL4 challenge, we assessed the ability of participants to evaluate not just their statistical uncertainty, but their model uncertainty – how well they can predict the magnitude of their model or force field error for specific predictions. Unfortunately, this remains an area where prediction and analysis need improvement. In SAMPL4 the top performing submissions achieved a root-mean-squared error (RMSE) around 1.5 kcal/mol. If we anticipate accuracy in log D predictions to be similar to the hydration free energy predictions in SAMPL4, the expected error here would be around 1.54 log units. Only a few submissions had an RMSE below 2.5 log units in their predicted log D values. However, distribution coefficients introduced complexities not present in past SAMPL challenges, including tautomer enumeration, that are likely to be important in predicting biomolecular properties of interest to drug discovery, therefore some decrease in accuracy would be expected. Overall, the SAMPL5 distribution coefficient challenge provided great insight into the importance of modeling a variety of physical effects. We believe these types of measurements will be a promising source of data for future blind challenges, especially in view of the relatively straightforward nature of the experiments and the level of insight provided. PMID:27677750
A method for atomic-level noncontact thermometry with electron energy distribution
NASA Astrophysics Data System (ADS)
Kinoshita, Ikuo; Tsukada, Chiharu; Ouchi, Kohei; Kobayashi, Eiichi; Ishii, Juntaro
2017-04-01
We devised a new method of determining the temperatures of materials with their electron-energy distributions. The Fermi-Dirac distribution convoluted with a linear combination of Gaussian and Lorentzian distributions was fitted to the photoelectron spectrum measured for the Au(110) single-crystal surface at liquid N2-cooled temperature. The fitting successfully determined the surface-local thermodynamic temperature and the energy resolution simultaneously from the photoelectron spectrum, without any preliminary results of other measurements. The determined thermodynamic temperature was 99 ± 2.1 K, which was in good agreement with the reference temperature of 98.5 ± 0.5 K measured using a silicon diode sensor attached to the sample holder.
A Maximum Entropy Test for Evaluating Higher-Order Correlations in Spike Counts
Onken, Arno; Dragoi, Valentin; Obermayer, Klaus
2012-01-01
Evaluating the importance of higher-order correlations of neural spike counts has been notoriously hard. A large number of samples are typically required in order to estimate higher-order correlations and resulting information theoretic quantities. In typical electrophysiology data sets with many experimental conditions, however, the number of samples in each condition is rather small. Here we describe a method that allows to quantify evidence for higher-order correlations in exactly these cases. We construct a family of reference distributions: maximum entropy distributions, which are constrained only by marginals and by linear correlations as quantified by the Pearson correlation coefficient. We devise a Monte Carlo goodness-of-fit test, which tests - for a given divergence measure of interest - whether the experimental data lead to the rejection of the null hypothesis that it was generated by one of the reference distributions. Applying our test to artificial data shows that the effects of higher-order correlations on these divergence measures can be detected even when the number of samples is small. Subsequently, we apply our method to spike count data which were recorded with multielectrode arrays from the primary visual cortex of anesthetized cat during an adaptation experiment. Using mutual information as a divergence measure we find that there are spike count bin sizes at which the maximum entropy hypothesis can be rejected for a substantial number of neuronal pairs. These results demonstrate that higher-order correlations can matter when estimating information theoretic quantities in V1. They also show that our test is able to detect their presence in typical in-vivo data sets, where the number of samples is too small to estimate higher-order correlations directly. PMID:22685392
Standardization for oxygen isotope ratio measurement - still an unsolved problem.
Kornexl; Werner; Gehre
1999-07-01
Numerous organic and inorganic laboratory standards were gathered from nine European and North American laboratories and were analyzed for their delta(18)O values with a new on-line high temperature pyrolysis system that was calibrated using Vienna standard mean ocean water (VSMOW) and standard light Antartic precipitation (SLAP) internationally distributed reference water samples. Especially for organic materials, discrepancies between reported and measured values were high, ranging up to 2 per thousand. The reasons for these discrepancies are discussed and the need for an exact and reliable calibration of existing reference materials, as well as for the establishment of additional organic and inorganic reference materials is stressed. Copyright 1999 John Wiley & Sons, Ltd.
Estimating regional centile curves from mixed data sources and countries.
van Buuren, Stef; Hayes, Daniel J; Stasinopoulos, D Mikis; Rigby, Robert A; ter Kuile, Feiko O; Terlouw, Dianne J
2009-10-15
Regional or national growth distributions can provide vital information on the health status of populations. In most resource poor countries, however, the required anthropometric data from purpose-designed growth surveys are not readily available. We propose a practical method for estimating regional (multi-country) age-conditional weight distributions based on existing survey data from different countries. We developed a two-step method by which one is able to model data with widely different age ranges and sample sizes. The method produces references both at the country level and at the regional (multi-country) level. The first step models country-specific centile curves by Box-Cox t and Box-Cox power exponential distributions implemented in generalized additive model for location, scale and shape through a common model. Individual countries may vary in location and spread. The second step defines the regional reference from a finite mixture of the country distributions, weighted by population size. To demonstrate the method we fitted the weight-for-age distribution of 12 countries in South East Asia and the Western Pacific, based on 273 270 observations. We modeled both the raw body weight and the corresponding Z score, and obtained a good fit between the final models and the original data for both solutions. We briefly discuss an application of the generated regional references to obtain appropriate, region specific, age-based dosing regimens of drugs used in the tropics. The method is an affordable and efficient strategy to estimate regional growth distributions where the standard costly alternatives are not an option. Copyright (c) 2009 John Wiley & Sons, Ltd.
On the use of Bayesian Monte-Carlo in evaluation of nuclear data
NASA Astrophysics Data System (ADS)
De Saint Jean, Cyrille; Archier, Pascal; Privas, Edwin; Noguere, Gilles
2017-09-01
As model parameters, necessary ingredients of theoretical models, are not always predicted by theory, a formal mathematical framework associated to the evaluation work is needed to obtain the best set of parameters (resonance parameters, optical models, fission barrier, average width, multigroup cross sections) with Bayesian statistical inference by comparing theory to experiment. The formal rule related to this methodology is to estimate the posterior density probability function of a set of parameters by solving an equation of the following type: pdf(posterior) ˜ pdf(prior) × a likelihood function. A fitting procedure can be seen as an estimation of the posterior density probability of a set of parameters (referred as x→?) knowing a prior information on these parameters and a likelihood which gives the probability density function of observing a data set knowing x→?. To solve this problem, two major paths could be taken: add approximations and hypothesis and obtain an equation to be solved numerically (minimum of a cost function or Generalized least Square method, referred as GLS) or use Monte-Carlo sampling of all prior distributions and estimate the final posterior distribution. Monte Carlo methods are natural solution for Bayesian inference problems. They avoid approximations (existing in traditional adjustment procedure based on chi-square minimization) and propose alternative in the choice of probability density distribution for priors and likelihoods. This paper will propose the use of what we are calling Bayesian Monte Carlo (referred as BMC in the rest of the manuscript) in the whole energy range from thermal, resonance and continuum range for all nuclear reaction models at these energies. Algorithms will be presented based on Monte-Carlo sampling and Markov chain. The objectives of BMC are to propose a reference calculation for validating the GLS calculations and approximations, to test probability density distributions effects and to provide the framework of finding global minimum if several local minimums exist. Application to resolved resonance, unresolved resonance and continuum evaluation as well as multigroup cross section data assimilation will be presented.
Satzke, Catherine; Dunne, Eileen M; Porter, Barbara D; Klugman, Keith P; Mulholland, E Kim
2015-11-01
The pneumococcus is a diverse pathogen whose primary niche is the nasopharynx. Over 90 different serotypes exist, and nasopharyngeal carriage of multiple serotypes is common. Understanding pneumococcal carriage is essential for evaluating the impact of pneumococcal vaccines. Traditional serotyping methods are cumbersome and insufficient for detecting multiple serotype carriage, and there are few data comparing the new methods that have been developed over the past decade. We established the PneuCarriage project, a large, international multi-centre study dedicated to the identification of the best pneumococcal serotyping methods for carriage studies. Reference sample sets were distributed to 15 research groups for blinded testing. Twenty pneumococcal serotyping methods were used to test 81 laboratory-prepared (spiked) samples. The five top-performing methods were used to test 260 nasopharyngeal (field) samples collected from children in six high-burden countries. Sensitivity and positive predictive value (PPV) were determined for the test methods and the reference method (traditional serotyping of >100 colonies from each sample). For the alternate serotyping methods, the overall sensitivity ranged from 1% to 99% (reference method 98%), and PPV from 8% to 100% (reference method 100%), when testing the spiked samples. Fifteen methods had ≥70% sensitivity to detect the dominant (major) serotype, whilst only eight methods had ≥70% sensitivity to detect minor serotypes. For the field samples, the overall sensitivity ranged from 74.2% to 95.8% (reference method 93.8%), and PPV from 82.2% to 96.4% (reference method 99.6%). The microarray had the highest sensitivity (95.8%) and high PPV (93.7%). The major limitation of this study is that not all of the available alternative serotyping methods were included. Most methods were able to detect the dominant serotype in a sample, but many performed poorly in detecting the minor serotype populations. Microarray with a culture amplification step was the top-performing method. Results from this comprehensive evaluation will inform future vaccine evaluation and impact studies, particularly in low-income settings, where pneumococcal disease burden remains high.
Satzke, Catherine; Dunne, Eileen M.; Porter, Barbara D.; Klugman, Keith P.; Mulholland, E. Kim
2015-01-01
Background The pneumococcus is a diverse pathogen whose primary niche is the nasopharynx. Over 90 different serotypes exist, and nasopharyngeal carriage of multiple serotypes is common. Understanding pneumococcal carriage is essential for evaluating the impact of pneumococcal vaccines. Traditional serotyping methods are cumbersome and insufficient for detecting multiple serotype carriage, and there are few data comparing the new methods that have been developed over the past decade. We established the PneuCarriage project, a large, international multi-centre study dedicated to the identification of the best pneumococcal serotyping methods for carriage studies. Methods and Findings Reference sample sets were distributed to 15 research groups for blinded testing. Twenty pneumococcal serotyping methods were used to test 81 laboratory-prepared (spiked) samples. The five top-performing methods were used to test 260 nasopharyngeal (field) samples collected from children in six high-burden countries. Sensitivity and positive predictive value (PPV) were determined for the test methods and the reference method (traditional serotyping of >100 colonies from each sample). For the alternate serotyping methods, the overall sensitivity ranged from 1% to 99% (reference method 98%), and PPV from 8% to 100% (reference method 100%), when testing the spiked samples. Fifteen methods had ≥70% sensitivity to detect the dominant (major) serotype, whilst only eight methods had ≥70% sensitivity to detect minor serotypes. For the field samples, the overall sensitivity ranged from 74.2% to 95.8% (reference method 93.8%), and PPV from 82.2% to 96.4% (reference method 99.6%). The microarray had the highest sensitivity (95.8%) and high PPV (93.7%). The major limitation of this study is that not all of the available alternative serotyping methods were included. Conclusions Most methods were able to detect the dominant serotype in a sample, but many performed poorly in detecting the minor serotype populations. Microarray with a culture amplification step was the top-performing method. Results from this comprehensive evaluation will inform future vaccine evaluation and impact studies, particularly in low-income settings, where pneumococcal disease burden remains high. PMID:26575033
Work ability of workers in western China: reference data.
Lin, Sihao; Wang, Zhiming; Wang, Mianzhen
2006-03-01
The Work Ability Index (WAI) is a validated and widely used research tool. Reference data for Chinese workers by age, gender and work content are poorly documented or lacking. To provide reference data for work ability among workers in western China. A random sample of 10 218 workers (including manual, professional, clerical and semi-skilled workers) in western China, aged 16-69 years, was taken from several studies and the WAI questionnaire was administered. All the WAI scores were distributed continuously and nearly normally. The WAI for female workers was significantly higher than for males (P < 0.01) and the 'poor' WAI category only accounted for 3% of females, against 6% of males. WAI scores declined with age and changed variably among workers according to work content and age. Mean WAI scores of manual workers declined rapidly beyond the age of 35 years, and beyond age 45 years for professional and clerical workers. WAI scores were distributed differently according to work content and age group (P < 0.01). WAI categories differed by work content and age group both for male and female workers. WAI is validated in Chinese occupational practices. Some reference data are different from Finnish data. This study provides gender, age and work-content-specific WAI reference values that will help enable comparison and intervention evaluation in further studies.
NASA Astrophysics Data System (ADS)
Menghan, Wang; Stefano, Albanese; Annamaria, Lima; Claudia, Cannatelli; Antonio, Cosenza; Wanjun, Lu; Marco, Sacchi; Angela, Doherty; Benedetto, De Vivo
2015-07-01
This paper presents the results of an environmental geochemical investigation of the Gulfs of Naples and Salerno, near the Campania plain (Southern Italy). Surface marine sediment samples were collected during three field campaigns: 96 from the Gulfs of Naples and Salerno (NaSa); 123 from the Bagnoli site coastal area (BaSi); and 11 from the ports around the Gulf of Naples (PoNa). Elemental concentrations were determined and their interpolated distribution maps were compiled. Three geochemical sources (or processes) were determined associating elemental distribution with the results obtained from a R-mode factor analysis: 1) geogenic, 2) water kinetics and 3) anthropogenic. The results are presented as raw data single element distributions of eight potential toxic elements (PTEs) (As, Cd, Cr, Cu, Hg, Pb, Ni and Zn) in the forms of raw data and additive log-ratio transformed data. The latter showed advantages in revealing the actual distribution patterns. Geochemical background reference values of PTEs were determined from the median value of local background reference values. Based on these values, pollution impact analysis was carried out to both BaSi and PoNa samples, indicating most of BaSi and PoNa sediments were affected by moderate to strong Pb, Zn, Cd and Hg pollution. An ecological risk assessment was subsequently carried out on the entire database, pointing a toxic risk ranking in the order Pb > As > Ni > Cd > Hg > Cr.
Three-beam interferogram analysis method for surface flatness testing of glass plates and wedges
NASA Astrophysics Data System (ADS)
Sunderland, Zofia; Patorski, Krzysztof
2015-09-01
When testing transparent plates with high quality flat surfaces and a small angle between them the three-beam interference phenomenon is observed. Since the reference beam and the object beams reflected from both the front and back surface of a sample are detected, the recorded intensity distribution may be regarded as a sum of three fringe patterns. Images of that type cannot be succesfully analyzed with standard interferogram analysis methods. They contain, however, useful information on the tested plate surface flatness and its optical thickness variations. Several methods were elaborated to decode the plate parameters. Our technique represents a competitive solution which allows for retrieval of phase components of the three-beam interferogram. It requires recording two images: a three-beam interferogram and the two-beam one with the reference beam blocked. Mutually subtracting these images leads to the intensity distribution which, under some assumptions, provides access to the two component fringe sets which encode surfaces flatness. At various stages of processing we take advantage of nonlinear operations as well as single-frame interferogram analysis methods. Two-dimensional continuous wavelet transform (2D CWT) is used to separate a particular fringe family from the overall interferogram intensity distribution as well as to estimate the phase distribution from a pattern. We distinguish two processing paths depending on the relative density of fringe sets which is connected with geometry of a sample and optical setup. The proposed method is tested on simulated data.
Wang, Qinghua; Ri, Shien; Tsuda, Hiroshi; Kodera, Masako; Suguro, Kyoichi; Miyashita, Naoto
2017-09-19
Quantitative detection of defects in atomic structures is of great significance to evaluating product quality and exploring quality improvement process. In this study, a Fourier transform filtered sampling Moire technique was proposed to visualize and detect defects in atomic arrays in a large field of view. Defect distributions, defect numbers and defect densities could be visually and quantitatively determined from a single atomic structure image at low cost. The effectiveness of the proposed technique was verified from numerical simulations. As an application, the dislocation distributions in a GaN/AlGaN atomic structure in two directions were magnified and displayed in Moire phase maps, and defect locations and densities were detected automatically. The proposed technique is able to provide valuable references to material scientists and engineers by checking the effect of various treatments for defect reduction. © 2017 IOP Publishing Ltd.
Synthetic Reference Materials Based on Polymer Films for the Control of Welding Fumes Composition
NASA Astrophysics Data System (ADS)
Kuznetsova, O. V.; Kuznetsova, A. N.; Begunova, L. A.
2017-04-01
Analysis of the current hygienic situation in the welding production showed that the intensification of welding processes involves the deterioration of air quality, which negatively affects the welders health. Welders are exposed to a variety of metal fumes, including manganese that may elevate the risk for neurological diseases. The control of metals concentration in the air of the working area is difficult due to the lack of reference materials. The creation of reference materials of welding fumes composition is a challenge due to chemical characteristics of their physical properties. Synthetic samples in a form of the polymer film containing powder particles of welding fumes were create. Studies on the selection of the polymer were done. Experiments proved that the qualitative materials of synthetic welding fumes are obtained by using polyvinyl alcohol. The metals concentration in the samples was determined by X-ray fluorescence analysis. The obtained data demonstrates indirectly the uniform distribution of welding fumes powder particles on the polymer film.
Reassessment of the Access Testosterone chemiluminescence assay and comparison with LC-MS method.
Dittadi, Ruggero; Matteucci, Mara; Meneghetti, Elisa; Ndreu, Rudina
2018-03-01
To reassess the imprecision and Limit of Quantitation, to evaluate the cross-reaction with dehydroepiandrosterone-sulfate (DHEAS), the accuracy toward liquid chromatography-mass spectrometry (LC-MS) and the reference interval of the Access Testosterone method, performed by DxI immunoassay platform (Beckman Coulter). Imprecision was evaluated testing six pool samples assayed in 20 different run using two reagents lots. The cross-reaction with DHEAS was studied both by a displacement curve and by spiking DHEAS standard in two serum samples with known amount of testosterone. The comparison with LC-MS was evaluated by Passing-Bablock analysis in 21 routine serum samples and 19 control samples from an External Quality Assurance (EQA) scheme. The reference interval was verified by an indirect estimation on 2445 male and 2838 female outpatients. The imprecision study showed a coefficient of variation (CV) between 2.7% and 34.7% for serum pools from 16.3 and 0.27 nmol/L. The value of Limit of Quantitation at 20% CV was 0.53 nmol/L. The DHEAS showed a cross-reaction of 0.0074%. A comparison with LC-MS showed a trend toward a slight underestimation of immunoassay vs LC-MS (Passing-Bablock equations: DxI=-0.24+0.906 LCMS in serum samples and DxI=-0.299+0.981 LCMS in EQA samples). The verification of reference interval showed a 2.5th-97.5th percentile distribution of 6.6-24.3 nmol/L for male over 14 years and <0.5-2.78 nmol/L for female subjects, in accord with the reference intervals reported by the manufacturer. The Access Testosterone method could be considered an adequately reliable tool for the testosterone measurement. © 2017 Wiley Periodicals, Inc.
Curating NASA's Past, Present, and Future Extraterrestrial Sample Collections
NASA Technical Reports Server (NTRS)
McCubbin, F. M.; Allton, J. H.; Evans, C. A.; Fries, M. D.; Nakamura-Messenger, K.; Righter, K.; Zeigler, R. A.; Zolensky, M.; Stansbery, E. K.
2016-01-01
The Astromaterials Acquisition and Curation Office (henceforth referred to herein as NASA Curation Office) at NASA Johnson Space Center (JSC) is responsible for curating all of NASA's extraterrestrial samples. Under the governing document, NASA Policy Directive (NPD) 7100.10E "Curation of Extraterrestrial Materials", JSC is charged with "...curation of all extra-terrestrial material under NASA control, including future NASA missions." The Directive goes on to define Curation as including "...documentation, preservation, preparation, and distribution of samples for research, education, and public outreach." Here we describe some of the past, present, and future activities of the NASA Curation Office.
NASA Astrophysics Data System (ADS)
Diaz-Rodriguez, Sebastian; Bozada, Samantha M.; Phifer, Jeremy R.; Paluch, Andrew S.
2016-11-01
We present blind predictions using the solubility parameter based method MOSCED submitted for the SAMPL5 challenge on calculating cyclohexane/water distribution coefficients at 298 K. Reference data to parameterize MOSCED was generated with knowledge only of chemical structure by performing solvation free energy calculations using electronic structure calculations in the SMD continuum solvent. To maintain simplicity and use only a single method, we approximate the distribution coefficient with the partition coefficient of the neutral species. Over the final SAMPL5 set of 53 compounds, we achieved an average unsigned error of 2.2± 0.2 log units (ranking 15 out of 62 entries), the correlation coefficient ( R) was 0.6± 0.1 (ranking 35), and 72± 6 % of the predictions had the correct sign (ranking 30). While used here to predict cyclohexane/water distribution coefficients at 298 K, MOSCED is broadly applicable, allowing one to predict temperature dependent infinite dilution activity coefficients in any solvent for which parameters exist, and provides a means by which an excess Gibbs free energy model may be parameterized to predict composition dependent phase-equilibrium.
Pearman, Timothy; Yanez, Betina; Peipert, John; Wortman, Katy; Beaumont, Jennifer; Cella, David
2014-09-15
Health-related quality of life (HRQOL) measures are commonly used in oncology research. Interest in their use for monitoring or screening is increasing. The Functional Assessment of Cancer Therapy (FACT) is one of the most widely used HRQOL instruments. Consequently, oncology researchers and practitioners have an increasing need for reference values for the Functional Assessment of Cancer Therapy-General (FACT-G) and its 7-item rapid version, the Functional Assessment of Cancer Therapy-General 7 (FACT-G7), to compare FACT scores across specific subgroups of patients in research trials and practice. The objectives of this study are to provide 1) reference values from a sample of the general US adult population and a sample of adults diagnosed with cancer and 2) cutoff scores for quality of life. A sample of the general US population (N = 1075) and a sample of patients with cancer from 12 studies (N = 5065) were analyzed. Cutoff scores were established using distribution- and anchor-based methods. Mean values for the cancer sample were analyzed by performance status, cancer type, and disease status. Also, t tests and established criteria for meaningful differences were used to compare values. FACT-G and FACT-G7 scores in the general US population sample and cancer sample were generally comparable. Among the sample of patients with cancer, FACT-G and FACT-G7 scores worsened with declining performance status and increasing disease status. These data will aid interpretation of the magnitude and meaning of FACT scores, and allow for comparisons of scores across studies. © 2014 American Cancer Society.
Ma, Jun; Wang, Zhiqiang; Song, Yi; Hu, Peijin; Zhang, Bing
2010-12-01
To establish BMI percentile curves that describe the contemporary BMI distribution among Chinese children, and to compare their BMI percentile curves with those in two recently developed international references: the WHO and the US Centers for Disease Control and Prevention (US CDC) growth references. A cross-sectional national survey. Thirty provinces, municipalities and autonomous regions in China. Nationally representative sample of 232 140 school students aged 7-18 years. BMI percentile curves were established using the LMS method, and were compared with the percentiles of the WHO and the US CDC references. BMI distributions and growth patterns in Chinese children were dramatically different from those in the two international reference populations. Compared with the international reference populations, younger Chinese boys (7-12 years of age) had higher values of the percentiles above the median and lower values of the percentiles below the median, suggesting that they had larger proportions of extreme BMI values in both directions. Chinese girls and older Chinese boys (15-18 years of age) had substantially lower BMI percentiles than their counterparts in the reference populations, particularly those high percentiles among older age groups. The present study described the unique patterns of BMI curves at the national level, and these curves are useful as a reference for comparing different regions and for monitoring changes over time in Chinese children. Higher proportions of children with extreme values in both directions indicate that China is currently facing both an increasing level of obesity and a high level of undernutrition, simultaneously.
Soils characterisation along ecological forest zones in the Eastern Himalayas
NASA Astrophysics Data System (ADS)
Simon, Alois; Dhendup, Kuenzang; Bahadur Rai, Prem; Gratzer, Georg
2017-04-01
Elevational gradients are commonly used to characterise vegetation patterns and, to a lesser extent, also to describe soil development. Furthermore, interactions between vegetation cover and soil characteristics are repeatedly observed. Combining information on soil development and easily to distinguish forest zones along elevational gradients, creates an added value for forest management decisions especially in less studied mountain regions. For this purpose, soil profiles along elevational gradients in the temperate conifer forests of Western and Central Bhutan, ranging from 2600-4000m asl were investigated. Thereby, 82 soil profiles were recorded and classified according to the World Reference Base for Soil Resources. Based on 19 representative profiles, genetic horizons were sampled and analysed. We aim to provide fundamental information on forest soil characteristics along these elevational transects. The results are presented with regard to ecological forest zones. The elevational distribution of the reference soil groups showed distinct distribution ranges for most of the soils. Cambisols were the most frequently recorded reference soil group with 58% of the sampled profiles, followed by Podzols in higher elevations, and Stagnosols, at intermediate elevations. Fluvisols occurred only at the lower end of the elevational transects and Phaeozems only at drier site conditions in the cool conifer dry forest zone. The humus layer thickness differs between forest zones and show a shift towards increased organic layer (O-layer) with increasing elevation. The reduced biomass productivity with increasing elevation and subsequently lower litter input compensates for the slow decomposition rates. The increasing O-layer thickness is an indicator of restrained intermixing of organic and mineral components by soil organisms at higher elevation. Overall, the soil types and soil characteristics along the elevational gradient showed a continuous and consistent change, instead of abrupt changes. We interpret these as manifestations of changes of temperature and precipitation with elevation which also drives forest zonation in these least anthropogenically influenced forest ecosystems. The elevational distribution of forest zones is correlated with the distribution of soil types and thus also reflects soil characteristics.
Van der Heyden, H; Dutilleul, P; Brodeur, L; Carisse, O
2014-06-01
Spatial distribution of single-nucleotide polymorphisms (SNPs) related to fungicide resistance was studied for Botrytis cinerea populations in vineyards and for B. squamosa populations in onion fields. Heterogeneity in this distribution was characterized by performing geostatistical analyses based on semivariograms and through the fitting of discrete probability distributions. Two SNPs known to be responsible for boscalid resistance (H272R and H272Y), both located on the B subunit of the succinate dehydrogenase gene, and one SNP known to be responsible for dicarboximide resistance (I365S) were chosen for B. cinerea in grape. For B. squamosa in onion, one SNP responsible for dicarboximide resistance (I365S homologous) was chosen. One onion field was sampled in 2009 and another one was sampled in 2010 for B. squamosa, and two vineyards were sampled in 2011 for B. cinerea, for a total of four sampled sites. Cluster sampling was carried on a 10-by-10 grid, each of the 100 nodes being the center of a 10-by-10-m quadrat. In each quadrat, 10 samples were collected and analyzed by restriction fragment length polymorphism polymerase chain reaction (PCR) or allele specific PCR. Mean SNP incidence varied from 16 to 68%, with an overall mean incidence of 43%. In the geostatistical analyses, omnidirectional variograms showed spatial autocorrelation characterized by ranges of 21 to 1 m. Various levels of anisotropy were detected, however, with variograms computed in four directions (at 0°, 45°, 90°, and 135° from the within-row direction used as reference), indicating that spatial autocorrelation was prevalent or characterized by a longer range in one direction. For all eight data sets, the β-binomial distribution was found to fit the data better than the binomial distribution. This indicates local aggregation of fungicide resistance among sampling units, as supported by estimates of the parameter θ of the β-binomial distribution of 0.09 to 0.23 (overall median value = 0.20). On the basis of the observed spatial distribution patterns of SNP incidence, sampling curves were computed for different levels of reliability, emphasizing the importance of sample size for the detection of mutation incidence below the risk threshold for control failure.
Joshi, Gagan; Faraone, Stephen V; Wozniak, Janet; Tarko, Laura; Fried, Ronna; Galdo, Maribel; Furtak, Stephannie L; Biederman, Joseph
2017-08-01
To compare the clinical presentation of ADHD between youth with autism spectrum disorder (ASD) and ADHD and a sample of youth with ADHD only. A psychiatrically referred sample of autism spectrum disorder (ASD) youth with ADHD attending a specialized ambulatory program for ASD ( n = 107) and a sample of youth with ADHD attending a general child psychiatry ambulatory clinic ( n = 74) were compared. Seventy-six percent of youth with ASD met Diagnostic and Statistical Manual of Mental Disorders (4th ed.; DSM-IV) criteria for ADHD. The clinical presentation of ADHD in youth with ASD was predominantly similar to its typical presentation including age at onset (3.5 ± 1.7 vs. 4.0 ± 1.9; p = .12), distribution of diagnostic subtypes, the qualitative and quantitative symptom profile, and symptom severity. Combined subtype was the most frequent presentation of ADHD in ASD youth. Despite the robust presentation of ADHD, a significant majority of ASD youth with ADHD failed to receive appropriate ADHD treatment (41% vs. 24%; p = .02). A high rate of comorbidity with ADHD was observed in psychiatrically referred youth with ASD, with a clinical presentation typical of the disorder.
Gref, Margareta C; Karp, Kjell H
2009-03-01
The single-sample Tc-diethylenetriamine penta-acetate (DTPA) clearance method by Christensen and Groth is recommended by the Radionuclides in Nephrourology Committee on Renal Clearance for use in adults with an estimated glomerular filtration rate (GFR) > or = 30 ml/min. The purpose of this study was to test a new Tc-DTPA single-sample low clearance formula for GFR lesser than 30 ml/min. Twenty-one adult patients (29 investigations) were included. Reference clearance was calculated with both Cr-EDTA and Tc-DTPA according to Brøchner-Mortensen with samples drawn between 3 and 24 h. Single-sample clearance was calculated from a 24 h sample using the low clearance formula(Equation is included in full-text article.) C(t) is the activity of the tracer in the plasma sample t minutes after the injection and Q0 is the injected amount. ECV is the extracellular volume in ml defined as the distribution volume of the tracer. ECV is estimated from the body surface area as ECV=8116.6xbody surface area-28.2. The mean difference between reference and Tc-DTPA single-sample clearance was -0.5 ml/min (SD 1.0 ml/min) for Tc-DTPA and -0.8 ml/min (SD 1.2 ml/min) for Cr-EDTA as reference clearance. In adult patients it is possible, even with GFR lesser than 30 ml/min, to get an accurate determination of Tc-DTPA plasma clearance from a single sample using the mean sojourn time approach. The blood sample should be obtained about 24 h after injection of the GFR tracer.
Asymptotic approximations to posterior distributions via conditional moment equations
Yee, J.L.; Johnson, W.O.; Samaniego, F.J.
2002-01-01
We consider asymptotic approximations to joint posterior distributions in situations where the full conditional distributions referred to in Gibbs sampling are asymptotically normal. Our development focuses on problems where data augmentation facilitates simpler calculations, but results hold more generally. Asymptotic mean vectors are obtained as simultaneous solutions to fixed point equations that arise naturally in the development. Asymptotic covariance matrices flow naturally from the work of Arnold & Press (1989) and involve the conditional asymptotic covariance matrices and first derivative matrices for conditional mean functions. When the fixed point equations admit an analytical solution, explicit formulae are subsequently obtained for the covariance structure of the joint limiting distribution, which may shed light on the use of the given statistical model. Two illustrations are given. ?? 2002 Biometrika Trust.
Compressive sampling of polynomial chaos expansions: Convergence analysis and sampling strategies
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hampton, Jerrad; Doostan, Alireza, E-mail: alireza.doostan@colorado.edu
2015-01-01
Sampling orthogonal polynomial bases via Monte Carlo is of interest for uncertainty quantification of models with random inputs, using Polynomial Chaos (PC) expansions. It is known that bounding a probabilistic parameter, referred to as coherence, yields a bound on the number of samples necessary to identify coefficients in a sparse PC expansion via solution to an ℓ{sub 1}-minimization problem. Utilizing results for orthogonal polynomials, we bound the coherence parameter for polynomials of Hermite and Legendre type under their respective natural sampling distribution. In both polynomial bases we identify an importance sampling distribution which yields a bound with weaker dependence onmore » the order of the approximation. For more general orthonormal bases, we propose the coherence-optimal sampling: a Markov Chain Monte Carlo sampling, which directly uses the basis functions under consideration to achieve a statistical optimality among all sampling schemes with identical support. We demonstrate these different sampling strategies numerically in both high-order and high-dimensional, manufactured PC expansions. In addition, the quality of each sampling method is compared in the identification of solutions to two differential equations, one with a high-dimensional random input and the other with a high-order PC expansion. In both cases, the coherence-optimal sampling scheme leads to similar or considerably improved accuracy.« less
Sidler, Dominik; Cristòfol-Clough, Michael; Riniker, Sereina
2017-06-13
Replica-exchange enveloping distribution sampling (RE-EDS) allows the efficient estimation of free-energy differences between multiple end-states from a single molecular dynamics (MD) simulation. In EDS, a reference state is sampled, which can be tuned by two types of parameters, i.e., smoothness parameters(s) and energy offsets, such that all end-states are sufficiently sampled. However, the choice of these parameters is not trivial. Replica exchange (RE) or parallel tempering is a widely applied technique to enhance sampling. By combining EDS with the RE technique, the parameter choice problem could be simplified and the challenge shifted toward an optimal distribution of the replicas in the smoothness-parameter space. The choice of a certain replica distribution can alter the sampling efficiency significantly. In this work, global round-trip time optimization (GRTO) algorithms are tested for the use in RE-EDS simulations. In addition, a local round-trip time optimization (LRTO) algorithm is proposed for systems with slowly adapting environments, where a reliable estimate for the round-trip time is challenging to obtain. The optimization algorithms were applied to RE-EDS simulations of a system of nine small-molecule inhibitors of phenylethanolamine N-methyltransferase (PNMT). The energy offsets were determined using our recently proposed parallel energy-offset (PEOE) estimation scheme. While the multistate GRTO algorithm yielded the best replica distribution for the ligands in water, the multistate LRTO algorithm was found to be the method of choice for the ligands in complex with PNMT. With this, the 36 alchemical free-energy differences between the nine ligands were calculated successfully from a single RE-EDS simulation 10 ns in length. Thus, RE-EDS presents an efficient method for the estimation of relative binding free energies.
Jamali, Jamshid; Ayatollahi, Seyyed Mohammad Taghi; Jafari, Peyman
2017-01-01
Evaluating measurement equivalence (also known as differential item functioning (DIF)) is an important part of the process of validating psychometric questionnaires. This study aimed at evaluating the multiple indicators multiple causes (MIMIC) model for DIF detection when latent construct distribution is nonnormal and the focal group sample size is small. In this simulation-based study, Type I error rates and power of MIMIC model for detecting uniform-DIF were investigated under different combinations of reference to focal group sample size ratio, magnitude of the uniform-DIF effect, scale length, the number of response categories, and latent trait distribution. Moderate and high skewness in the latent trait distribution led to a decrease of 0.33% and 0.47% power of MIMIC model for detecting uniform-DIF, respectively. The findings indicated that, by increasing the scale length, the number of response categories and magnitude DIF improved the power of MIMIC model, by 3.47%, 4.83%, and 20.35%, respectively; it also decreased Type I error of MIMIC approach by 2.81%, 5.66%, and 0.04%, respectively. This study revealed that power of MIMIC model was at an acceptable level when latent trait distributions were skewed. However, empirical Type I error rate was slightly greater than nominal significance level. Consequently, the MIMIC was recommended for detection of uniform-DIF when latent construct distribution is nonnormal and the focal group sample size is small.
Jafari, Peyman
2017-01-01
Evaluating measurement equivalence (also known as differential item functioning (DIF)) is an important part of the process of validating psychometric questionnaires. This study aimed at evaluating the multiple indicators multiple causes (MIMIC) model for DIF detection when latent construct distribution is nonnormal and the focal group sample size is small. In this simulation-based study, Type I error rates and power of MIMIC model for detecting uniform-DIF were investigated under different combinations of reference to focal group sample size ratio, magnitude of the uniform-DIF effect, scale length, the number of response categories, and latent trait distribution. Moderate and high skewness in the latent trait distribution led to a decrease of 0.33% and 0.47% power of MIMIC model for detecting uniform-DIF, respectively. The findings indicated that, by increasing the scale length, the number of response categories and magnitude DIF improved the power of MIMIC model, by 3.47%, 4.83%, and 20.35%, respectively; it also decreased Type I error of MIMIC approach by 2.81%, 5.66%, and 0.04%, respectively. This study revealed that power of MIMIC model was at an acceptable level when latent trait distributions were skewed. However, empirical Type I error rate was slightly greater than nominal significance level. Consequently, the MIMIC was recommended for detection of uniform-DIF when latent construct distribution is nonnormal and the focal group sample size is small. PMID:28713828
Smooth quantile normalization.
Hicks, Stephanie C; Okrah, Kwame; Paulson, Joseph N; Quackenbush, John; Irizarry, Rafael A; Bravo, Héctor Corrada
2018-04-01
Between-sample normalization is a critical step in genomic data analysis to remove systematic bias and unwanted technical variation in high-throughput data. Global normalization methods are based on the assumption that observed variability in global properties is due to technical reasons and are unrelated to the biology of interest. For example, some methods correct for differences in sequencing read counts by scaling features to have similar median values across samples, but these fail to reduce other forms of unwanted technical variation. Methods such as quantile normalization transform the statistical distributions across samples to be the same and assume global differences in the distribution are induced by only technical variation. However, it remains unclear how to proceed with normalization if these assumptions are violated, for example, if there are global differences in the statistical distributions between biological conditions or groups, and external information, such as negative or control features, is not available. Here, we introduce a generalization of quantile normalization, referred to as smooth quantile normalization (qsmooth), which is based on the assumption that the statistical distribution of each sample should be the same (or have the same distributional shape) within biological groups or conditions, but allowing that they may differ between groups. We illustrate the advantages of our method on several high-throughput datasets with global differences in distributions corresponding to different biological conditions. We also perform a Monte Carlo simulation study to illustrate the bias-variance tradeoff and root mean squared error of qsmooth compared to other global normalization methods. A software implementation is available from https://github.com/stephaniehicks/qsmooth.
Speech waveform perturbation analysis: a perceptual-acoustical comparison of seven measures.
Askenfelt, A G; Hammarberg, B
1986-03-01
The performance of seven acoustic measures of cycle-to-cycle variations (perturbations) in the speech waveform was compared. All measures were calculated automatically and applied on running speech. Three of the measures refer to the frequency of occurrence and severity of waveform perturbations in special selected parts of the speech, identified by means of the rate of change in the fundamental frequency. Three other measures refer to statistical properties of the distribution of the relative frequency differences between adjacent pitch periods. One perturbation measure refers to the percentage of consecutive pitch period differences with alternating signs. The acoustic measures were tested on tape recorded speech samples from 41 voice patients, before and after successful therapy. Scattergrams of acoustic waveform perturbation data versus an average of perceived deviant voice qualities, as rated by voice clinicians, are presented. The perturbation measures were compared with regard to the acoustic-perceptual correlation and their ability to discriminate between normal and pathological voice status. The standard deviation of the distribution of the relative frequency differences was suggested as the most useful acoustic measure of waveform perturbations for clinical applications.
Protano, Carmela; Andreoli, Roberta; Manigrasso, Maurizio; Vitali, Matteo
2018-01-01
(1) Background: Environmental Tobacco Smoke (ETS) exposure remains a public health problem worldwide. The aims are to establish urinary (u-) cotinine reference values for healthy Italian children, to evaluate the role of the sampling time and of other factors on children’s u-cotinine excretion. (2) Methods: A cross-sectional study was performed on 330 children. Information on participants was gathered by a questionnaire and u-cotinine was determined in two samples for each child, collected during the evening and the next morning. (3) Results: Reference intervals (as the 2.5th and 97.5th percentiles of the distribution) in evening and morning samples were respectively equal to 0.98–4.29 and 0.91–4.50 µg L−1 (ETS unexposed) and 1.39–16.34 and 1.49–20.95 µg L−1 (ETS exposed). No statistical differences were recovered between median values found in evening and morning samples, both in ETS unexposed and exposed. Significant predictors of u-cotinine excretions were ponderal status according to body mass index of children (β = 0.202; p-value = 0.041 for evening samples; β = 0.169; p-value = 0.039 for morning samples) and paternal educational level (β = −0.258; p-value = 0.010; for evening samples; β = −0.013; p-value = 0.003 for morning samples). (4) Conclusions: The results evidenced the need of further studies for assessing the role of confounding factors on ETS exposure, and the necessity of educational interventions on smokers for rising their awareness about ETS. PMID:29690510
Analysis of Mass Averaged Tissue Doses in CAM, CAF, MAX, and FAX
NASA Technical Reports Server (NTRS)
Slaba, Tony C.; Qualls, Garry D.; Clowdsley, Martha S.; Blattnig, Steve R.; Simonsen, Lisa C.; Walker, Steven A.; Singleterry, Robert C.
2009-01-01
To estimate astronaut health risk due to space radiation, one must have the ability to calculate exposure-related quantities averaged over specific organs and tissue types. In this study, we first examine the anatomical properties of the Computerized Anatomical Man (CAM), Computerized Anatomical Female (CAF), Male Adult voXel (MAX), and Female Adult voXel (FAX) models by comparing the masses of various tissues to the reference values specified by the International Commission on Radiological Protection (ICRP). Major discrepancies are found between the CAM and CAF tissue masses and the ICRP reference data for almost all of the tissues. We next examine the distribution of target points used with the deterministic transport code HZETRN to compute mass averaged exposure quantities. A numerical algorithm is used to generate multiple point distributions for many of the effective dose tissues identified in CAM, CAF, MAX, and FAX. It is concluded that the previously published CAM and CAF point distributions were under-sampled and that the set of point distributions presented here should be adequate for future studies involving CAM, CAF, MAX, or FAX. It is concluded that MAX and FAX are more accurate than CAM and CAF for space radiation analyses.
Local-order metric for condensed-phase environments
NASA Astrophysics Data System (ADS)
Martelli, Fausto; Ko, Hsin-Yu; Oǧuz, Erdal C.; Car, Roberto
2018-02-01
We introduce a local order metric (LOM) that measures the degree of order in the neighborhood of an atomic or molecular site in a condensed medium. The LOM maximizes the overlap between the spatial distribution of sites belonging to that neighborhood and the corresponding distribution in a suitable reference system. The LOM takes a value tending to zero for completely disordered environments and tending to one for environments that perfectly match the reference. The site-averaged LOM and its standard deviation define two scalar order parameters, S and δ S , that characterize with excellent resolution crystals, liquids, and amorphous materials. We show with molecular dynamics simulations that S , δ S , and the LOM provide very insightful information in the study of structural transformations, such as those occurring when ice spontaneously nucleates from supercooled water or when a supercooled water sample becomes amorphous upon progressive cooling.
Wilcoxon's signed-rank statistic: what null hypothesis and why it matters.
Li, Heng; Johnson, Terri
2014-01-01
In statistical literature, the term 'signed-rank test' (or 'Wilcoxon signed-rank test') has been used to refer to two distinct tests: a test for symmetry of distribution and a test for the median of a symmetric distribution, sharing a common test statistic. To avoid potential ambiguity, we propose to refer to those two tests by different names, as 'test for symmetry based on signed-rank statistic' and 'test for median based on signed-rank statistic', respectively. The utility of such terminological differentiation should become evident through our discussion of how those tests connect and contrast with sign test and one-sample t-test. Published 2014. This article is a U.S. Government work and is in the public domain in the USA. Published 2014. This article is a U.S. Government work and is in the public domain in the USA.
Speciation of strontium-90 in NIST natural matrix standard reference materials
DOE Office of Scientific and Technical Information (OSTI.GOV)
Thomas, J.W.L.; Inn, K.G.W.; Garcia, M.E.
1995-12-31
A sequential leaching, radiochemical separating, and low-level beta-particle counting procedure was designed to study the speciation of radionuclides in natural matrix standard reference materials, SRMs 4350B (Columbia River Sediment) and 4353 (Rocky Flats Soil-1). Strontium-90 is the first radionuclide studied because of the difficulty experienced with this nuclide in natural-matrix SRMs. The nine-step procedure extracted {sup 90}Sr from the following fractions: water solubles, exchangeables, carbonates, reducibles, organics, iron and manganese oxides, acid leachables, micas, and silicates. The majority of {sup 90}Sr in the soil samples was found in the exchangeable fraction. By contrast, the {sup 90}Sr in the sediment ismore » more evenly distributed among the various leached fractions. Information on the leach distribution of radionuclides in environmental SRMs, based on the procedure described, should lead to more cost-effective restoration strategies and more confidence in risk assessments of human health hazards.« less
Antimony exposure and speciation in human biomarkers near an active mining area in Hunan, China.
Ye, Li; Qiu, Shixin; Li, Xinhai; Jiang, Yuxuan; Jing, Chuanyong
2018-05-28
Antimony (Sb) exposure threatens human health. To identify human biomarkers for Sb exposure, we analyzed 480 environmental samples from an active Sb mining area in Hunan, China. Elevated Sb concentrations exceeding the reference level were detected in drinking water (70% of n = 83 total samples), foods (80%, n = 188), urine (95%, n = 63), saliva (44%, n = 48), hair (80%, n = 51) and nails (83%, n = 47). Drinking water contributed 85%-100% of the average daily dose (ADD) of Sb, and the total ADD (11.7 μg/kg bodyweight/day) was up to thirty times higher than the oral reference dose (0.4 μg/kg bodyweight/day) as recommended by USEPA. A positive correlation was found between ADD and Sb content in hair (p = 0.02), but not in urine (p = 0.051), saliva (p = 0.52) or nails (p = 0.85), suggesting that hair is the best non-invasive biomarker. Micro X-ray fluorescence analysis indicated that Sb is distributed in discrete spots in hair and nails, and Sb distribution is correlated with other metals. Methylated Sb species were predominant in urine (46%-100%) and saliva (74%-100%) in collected samples, implying that the human metabolic system adopts methylation as an effective pathway to detoxify and excrete Sb. Copyright © 2018 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Lander, D. M. P.; McCanty, S. T.; Dimino, T. F.; Christian, A. D.
2016-02-01
The River Continuum Concept (RCC) predicts stream biological communities based on dominant physical structures and energy inputs into streams and predicts how these features and corresponding communities change along the stream continuum. Verifying RCC expectations is important for creating valid points of comparison during stream ecosystem evaluation. These reference expectations are critical for restoration projects, such as the restoration of decommissioned cranberry bogs. Our research compares the physical habitat and freshwater invertebrate functional feeding groups (FWIFFG) of reference, active cranberry farming, and cranberry farm passive restoration sites in Northeastern Coastal Zone streams of Massachusetts to the specific RCC FWIFFG predictions. We characterized stream physical habitat using a semi-quantitative habitat characterization protocol and sampled freshwater invertebrates using the U.S. EPA standard 20-jab multi-habitat protocol. We expected that stream habitat would be most homogeneous at active farming stations, intermediate at restoration stations, and most heterogeneous at reference stations. Furthermore, we expected reference stream FWIFFG would be accurately predicted by the RCC and distributions at restoration and active sites would vary significantly. Habitat data was analyzed using a principle component analysis and results confirmed our predictions showing more homogeneous habitat for the active and reference stations, while showing a more heterogeneous habitat at the reference stations. The FWIFFG chi-squared analysis showed significant deviation from our specific RCC FWIFFG predictions. Because published FWIFFG distributions did not match our empirical values for a least disturbed Northeastern Coastal Zone headwater stream, using our data as a community structure template for current and future restoration projects is not recommend without further considerations.
A REFERENCE-INVARIANT HEALTH DISPARITY INDEX BASED ON RÉNYI DIVERGENCE
Talih, Makram
2015-01-01
One of four overarching goals of Healthy People 2020 (HP2020) is to achieve health equity, eliminate disparities, and improve the health of all groups. In health disparity indices (HDIs) such as the mean log deviation (MLD) and Theil index (TI), disparities are relative to the population average, whereas in the index of disparity (IDisp) the reference is the group with the least adverse health outcome. Although the latter may be preferable, identification of a reference group can be affected by statistical reliability. To address this issue, we propose a new HDI, the Rényi index (RI), which is reference-invariant. When standardized, the RI extends the Atkinson index, where a disparity aversion parameter can incorporate societal values associated with health equity. In addition, both the MLD and TI are limiting cases of the RI. Also, a symmetrized Rényi index (SRI) can be constructed, resulting in a symmetric measure in the two distributions whose relative entropy is being evaluated. We discuss alternative symmetric and reference-invariant HDIs derived from the generalized entropy (GE) class and the Bregman divergence, and argue that the SRI is more robust than its GE-based counterpart to small changes in the distribution of the adverse health outcome. We evaluate the design-based standard errors and bootstrapped sampling distributions for the SRI, and illustrate the proposed methodology using data from the National Health and Nutrition Examination Survey (NHANES) on the 2001–04 prevalence of moderate or severe periodontitis among adults aged 45–74, which tracks Oral Health objective OH-5 in HP2020. Such data, which uses a binary individual-level outcome variable, are typical of HP2020 data. PMID:26568778
A REFERENCE-INVARIANT HEALTH DISPARITY INDEX BASED ON RÉNYI DIVERGENCE.
Talih, Makram
One of four overarching goals of Healthy People 2020 (HP2020) is to achieve health equity, eliminate disparities, and improve the health of all groups. In health disparity indices (HDIs) such as the mean log deviation (MLD) and Theil index (TI), disparities are relative to the population average, whereas in the index of disparity (IDisp) the reference is the group with the least adverse health outcome. Although the latter may be preferable, identification of a reference group can be affected by statistical reliability. To address this issue, we propose a new HDI, the Rényi index (RI), which is reference-invariant. When standardized, the RI extends the Atkinson index, where a disparity aversion parameter can incorporate societal values associated with health equity. In addition, both the MLD and TI are limiting cases of the RI. Also, a symmetrized Rényi index (SRI) can be constructed, resulting in a symmetric measure in the two distributions whose relative entropy is being evaluated. We discuss alternative symmetric and reference-invariant HDIs derived from the generalized entropy (GE) class and the Bregman divergence, and argue that the SRI is more robust than its GE-based counterpart to small changes in the distribution of the adverse health outcome. We evaluate the design-based standard errors and bootstrapped sampling distributions for the SRI, and illustrate the proposed methodology using data from the National Health and Nutrition Examination Survey (NHANES) on the 2001-04 prevalence of moderate or severe periodontitis among adults aged 45-74, which tracks Oral Health objective OH-5 in HP2020. Such data, which uses a binary individual-level outcome variable, are typical of HP2020 data.
Pine, P S; Boedigheimer, M; Rosenzweig, B A; Turpaz, Y; He, Y D; Delenstarr, G; Ganter, B; Jarnagin, K; Jones, W D; Reid, L H; Thompson, K L
2008-11-01
Effective use of microarray technology in clinical and regulatory settings is contingent on the adoption of standard methods for assessing performance. The MicroArray Quality Control project evaluated the repeatability and comparability of microarray data on the major commercial platforms and laid the groundwork for the application of microarray technology to regulatory assessments. However, methods for assessing performance that are commonly applied to diagnostic assays used in laboratory medicine remain to be developed for microarray assays. A reference system for microarray performance evaluation and process improvement was developed that includes reference samples, metrics and reference datasets. The reference material is composed of two mixes of four different rat tissue RNAs that allow defined target ratios to be assayed using a set of tissue-selective analytes that are distributed along the dynamic range of measurement. The diagnostic accuracy of detected changes in expression ratios, measured as the area under the curve from receiver operating characteristic plots, provides a single commutable value for comparing assay specificity and sensitivity. The utility of this system for assessing overall performance was evaluated for relevant applications like multi-laboratory proficiency testing programs and single-laboratory process drift monitoring. The diagnostic accuracy of detection of a 1.5-fold change in signal level was found to be a sensitive metric for comparing overall performance. This test approaches the technical limit for reliable discrimination of differences between two samples using this technology. We describe a reference system that provides a mechanism for internal and external assessment of laboratory proficiency with microarray technology and is translatable to performance assessments on other whole-genome expression arrays used for basic and clinical research.
Fancher, Chris M.; Han, Zhen; Levin, Igor; Page, Katharine; Reich, Brian J.; Smith, Ralph C.; Wilson, Alyson G.; Jones, Jacob L.
2016-01-01
A Bayesian inference method for refining crystallographic structures is presented. The distribution of model parameters is stochastically sampled using Markov chain Monte Carlo. Posterior probability distributions are constructed for all model parameters to properly quantify uncertainty by appropriately modeling the heteroskedasticity and correlation of the error structure. The proposed method is demonstrated by analyzing a National Institute of Standards and Technology silicon standard reference material. The results obtained by Bayesian inference are compared with those determined by Rietveld refinement. Posterior probability distributions of model parameters provide both estimates and uncertainties. The new method better estimates the true uncertainties in the model as compared to the Rietveld method. PMID:27550221
[Diagnostic reference levels in interventional radiology].
Vañó Carruana, E; Fernández Soto, J M; Sánchez Casanueva, R M; Ten Morón, J I
2013-12-01
This article discusses the diagnostic reference levels for radiation exposure proposed by the International Commission on Radiological Protection (ICRP) to facilitate the application of the optimization criteria in diagnostic imaging and interventional procedures. These levels are normally established as the third quartile of the dose distributions to patients in an ample sample of centers and are supposed to be representative of good practice regarding patient exposure. In determining these levels, it is important to evaluate image quality as well to ensure that it is sufficient for diagnostic purposes. When the values for the dose received by patients are systematically higher or much lower than the reference levels, an investigation should determine whether corrective measures need to be applied. The European and Spanish regulations require the use of these reference values in quality assurance programs. For interventional procedures, the dose area product (or kerma area product) values are usually used as reference values together with the time under fluoroscopy and the total number of images acquired. The most modern imaging devices allow the value of the accumulated dose at the entrance to the patient to be calculated to optimize the distribution of the dose on the skin. The ICRP recommends that the complexity of interventional procedures be taken into account when establishing reference levels. In the future, diagnostic imaging departments will have automatic systems to manage patient dosimetric data; these systems will enable continuous dosage auditing and alerts about individual procedures that might involve doses several times above the reference values. This article also discusses aspects that need to be clarified to take better advantage of the reference levels in interventional procedures. Copyright © 2013 SERAM. Published by Elsevier Espana. All rights reserved.
Tian, Ying; Yao, Yiming; Chang, Shuai; Zhao, Zhen; Zhao, Yangyang; Yuan, Xiaojia; Wu, Fengchang; Sun, Hongwen
2018-02-06
A total of 23 per- and polyfluoroalkyl substances (PFASs) were investigated in the air, dry deposition, and plant leaves at two different landfills and one suburban reference site in Tianjin, China. The potential of landfills as sources of PFASs to the atmosphere and the phase distribution therein were evaluated. The maximum concentrations of ∑PFASs in the two landfills were up to 9.5 ng/m 3 in the air, 4.1 μg/g in dry deposition, and 48 μg/g lipid in leaves with trifluoroacetic acid and perfluoropropionic acid being dominant (71%-94%). Spatially, the distribution trend of ionizable and neutral PFASs in all three kinds of media consistently showed the central landfill > the downwind > the upwind > the reference sites, indicating that landfills are important sources to PFASs in the environment. Plant leaves were found effective in uptake of a variety of airborne PFASs including polyfluoroalkyl phosphoric acid diesters, thus capable of acting as a passive air sampling approach for air monitoring.
The behavior of Metropolis-coupled Markov chains when sampling rugged phylogenetic distributions.
Brown, Jeremy M; Thomson, Robert C
2018-02-15
Bayesian phylogenetic inference involves sampling from posterior distributions of trees, which sometimes exhibit local optima, or peaks, separated by regions of low posterior density. Markov chain Monte Carlo (MCMC) algorithms are the most widely used numerical method for generating samples from these posterior distributions, but they are susceptible to entrapment on individual optima in rugged distributions when they are unable to easily cross through or jump across regions of low posterior density. Ruggedness of posterior distributions can result from a variety of factors, including unmodeled variation in evolutionary processes and unrecognized variation in the true topology across sites or genes. Ruggedness can also become exaggerated when constraints are placed on topologies that require the presence or absence of particular bipartitions (often referred to as positive or negative constraints, respectively). These types of constraints are frequently employed when conducting tests of topological hypotheses (Bergsten et al. 2013; Brown and Thomson 2017). Negative constraints can lead to particularly rugged distributions when the data strongly support a forbidden clade, because monophyly of the clade can be disrupted by inserting outgroup taxa in many different ways. However, topological moves between the alternative disruptions are very difficult, because they require swaps between the inserted outgroup taxa while the data constrain taxa from the forbidden clade to remain close together on the tree. While this precise form of ruggedness is particular to negative constraints, trees with high posterior density can be separated by similarly complicated topological rearrangements, even in the absence of constraints.
The distribution of early- and late-type galaxies in the Coma cluster
NASA Technical Reports Server (NTRS)
Doi, M.; Fukugita, M.; Okamura, S.; Turner, E. L.
1995-01-01
The spatial distribution and the morohology-density relation of Coma cluster galaxies are studied using a new homogeneous photmetric sample of 450 galaxies down to B = 16.0 mag with quantitative morphology classification. The sample covers a wide area (10 deg X 10 deg), extending well beyond the Coma cluster. Morphological classifications into early- (E+SO) and late-(S) type galaxies are made by an automated algorithm using simple photometric parameters, with which the misclassification rate is expected to be approximately 10% with respect to early and late types given in the Third Reference Catalogue of Bright Galaxies. The flattened distribution of Coma cluster galaxies, as noted in previous studies, is most conspicuously seen if the early-type galaxies are selected. Early-type galaxies are distributed in a thick filament extended from the NE to the WSW direction that delineates a part of large-scale structure. Spiral galaxies show a distribution with a modest density gradient toward the cluster center; at least bright spiral galaxies are present close to the center of the Coma cluster. We also examine the morphology-density relation for the Coma cluster including its surrounding regions.
Analysis of the NMI01 marker for a population database of cannabis seeds.
Shirley, Nicholas; Allgeier, Lindsay; Lanier, Tommy; Coyle, Heather Miller
2013-01-01
We have analyzed the distribution of genotypes at a single hexanucleotide short tandem repeat (STR) locus in a Cannabis sativa seed database along with seed-packaging information. This STR locus is defined by the polymerase chain reaction amplification primers CS1F and CS1R and is referred to as NMI01 (for National Marijuana Initiative) in our study. The population database consists of seed seizures of two categories: seed samples from labeled and unlabeled packages regarding seed bank source. Of a population database of 93 processed seeds including 12 labeled Cannabis varieties, the observed genotypes generated from single seeds exhibited between one and three peaks (potentially six alleles if in homozygous state). The total number of observed genotypes was 54 making this marker highly specific and highly individualizing even among seeds of common lineage. Cluster analysis associated many but not all of the handwritten labeled seed varieties tested to date as well as the National Park seizure to our known reference database containing Mr. Nice Seedbank and Sensi Seeds commercially packaged reference samples. © 2012 American Academy of Forensic Sciences.
Computer methods for sampling from the gamma distribution
DOE Office of Scientific and Technical Information (OSTI.GOV)
Johnson, M.E.; Tadikamalla, P.R.
1978-01-01
Considerable attention has recently been directed at developing ever faster algorithms for generating gamma random variates on digital computers. This paper surveys the current state of the art including the leading algorithms of Ahrens and Dieter, Atkinson, Cheng, Fishman, Marsaglia, Tadikamalla, and Wallace. General random variate generation techniques are explained with reference to these gamma algorithms. Computer simulation experiments on IBM and CDC computers are reported.
NASA Technical Reports Server (NTRS)
Warren, W. H., Jr.
1983-01-01
The machine readable catalog, as it is distributed from the Astronomical Data Center, is described. Some minor reformatting of the magnetic tape version is received to decrease the record size and conserve space; the data content is identical to the sample shown in Table VI of the source reference.
Ogawa, Y; Wada, B; Taniguchi, K; Miyasaka, S; Imaizumi, K
2015-12-01
This study clarifies the anthropometric variations of the Japanese face by presenting large-sample population data of photo anthropometric measurements. The measurements can be used as standard reference data for the personal identification of facial images in forensic practices. To this end, three-dimensional (3D) facial images of 1126 Japanese individuals (865 male and 261 female Japanese individuals, aged 19-60 years) were acquired as samples using an already validated 3D capture system, and normative anthropometric analysis was carried out. In this anthropometric analysis, first, anthropological landmarks (22 items, i.e., entocanthion (en), alare (al), cheilion (ch), zygion (zy), gonion (go), sellion (se), gnathion (gn), labrale superius (ls), stomion (sto), labrale inferius (li)) were positioned on each 3D facial image (the direction of which had been adjusted to the Frankfort horizontal plane as the standard position for appropriate anthropometry), and anthropometric absolute measurements (19 items, i.e., bientocanthion breadth (en-en), nose breadth (al-al), mouth breadth (ch-ch), bizygomatic breadth (zy-zy), bigonial breadth (go-go), morphologic face height (se-gn), upper-lip height (ls-sto), lower-lip height (sto-li)) were exported using computer software for the measurement of a 3D digital object. Second, anthropometric indices (21 items, i.e., (se-gn)/(zy-zy), (en-en)/(al-al), (ls-li)/(ch-ch), (ls-sto)/(sto-li)) were calculated from these exported measurements. As a result, basic statistics, such as the mean values, standard deviations, and quartiles, and details of the distributions of these anthropometric results were shown. All of the results except "upper/lower lip ratio (ls-sto)/(sto-li)" were normally distributed. They were acquired as carefully as possible employing a 3D capture system and 3D digital imaging technologies. The sample of images was much larger than any Japanese sample used before for the purpose of personal identification. The measurements will be useful as standard reference data for forensic practices and as material data for future studies in this field. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
SU-E-J-85: Leave-One-Out Perturbation (LOOP) Fitting Algorithm for Absolute Dose Film Calibration
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chu, A; Ahmad, M; Chen, Z
2014-06-01
Purpose: To introduce an outliers-recognition fitting routine for film dosimetry. It cannot only be flexible with any linear and non-linear regression but also can provide information for the minimal number of sampling points, critical sampling distributions and evaluating analytical functions for absolute film-dose calibration. Methods: The technique, leave-one-out (LOO) cross validation, is often used for statistical analyses on model performance. We used LOO analyses with perturbed bootstrap fitting called leave-one-out perturbation (LOOP) for film-dose calibration . Given a threshold, the LOO process detects unfit points (“outliers”) compared to other cohorts, and a bootstrap fitting process follows to seek any possibilitiesmore » of using perturbations for further improvement. After that outliers were reconfirmed by a traditional t-test statistics and eliminated, then another LOOP feedback resulted in the final. An over-sampled film-dose- calibration dataset was collected as a reference (dose range: 0-800cGy), and various simulated conditions for outliers and sampling distributions were derived from the reference. Comparisons over the various conditions were made, and the performance of fitting functions, polynomial and rational functions, were evaluated. Results: (1) LOOP can prove its sensitive outlier-recognition by its statistical correlation to an exceptional better goodness-of-fit as outliers being left-out. (2) With sufficient statistical information, the LOOP can correct outliers under some low-sampling conditions that other “robust fits”, e.g. Least Absolute Residuals, cannot. (3) Complete cross-validated analyses of LOOP indicate that the function of rational type demonstrates a much superior performance compared to the polynomial. Even with 5 data points including one outlier, using LOOP with rational function can restore more than a 95% value back to its reference values, while the polynomial fitting completely failed under the same conditions. Conclusion: LOOP can cooperate with any fitting routine functioning as a “robust fit”. In addition, it can be set as a benchmark for film-dose calibration fitting performance.« less
Joshi, Gagan; Faraone, Stephen V.; Wozniak, Janet; Tarko, Laura; Fried, Ronna; Galdo, Maribel; Furtak, Stephannie L.; Biederman, Joseph
2014-01-01
Objective To compare the clinical presentation of ADHD between youth with autism spectrum disorder (ASD) and ADHD and a sample of youth with ADHD only. Method A psychiatrically referred sample of autism spectrum disorder (ASD) youth with ADHD attending a specialized ambulatory program for ASD (n = 107) and a sample of youth with ADHD attending a general child psychiatry ambulatory clinic (n = 74) were compared. Results Seventy-six percent of youth with ASD met Diagnostic and Statistical Manual of Mental Disorders (4th ed.; DSM-IV) criteria for ADHD. The clinical presentation of ADHD in youth with ASD was predominantly similar to its typical presentation including age at onset (3.5 ± 1.7 vs. 4.0 ± 1.9; p = .12), distribution of diagnostic subtypes, the qualitative and quantitative symptom profile, and symptom severity. Combined subtype was the most frequent presentation of ADHD in ASD youth. Conclusion Despite the robust presentation of ADHD, a significant majority of ASD youth with ADHD failed to receive appropriate ADHD treatment (41% vs. 24%; p = .02). A high rate of comorbidity with ADHD was observed in psychiatrically referred youth with ASD, with a clinical presentation typical of the disorder. PMID:25085653
Liu, Rui; Yan, Hui; Duan, Jin-Ao; Liu, Xing-Jian; Ren, Quan-Jin; Li, Hui-Wei; Bao, Bei-Hua; Zhang, Zhao-Hui
2016-08-01
According to the technology requirements of the fourth national survey of Chinese Materia Medica resources (pilot), suitable investigation method of exploration and suggestions for investigating Chinese Materia Medica resources was proposed based on the type of wetland and artificial water of Hongze Lake region. Environment of Hongze Lake and overview of wetland, present situation of ecology and vegetation and vegetation distribution were analyzed. Establishment of survey plan, selection of sample area and sample square and confirmation of representative water area survey plan were all suggested. The present study provide references for improving Chinese materia medica resources survey around Hongze Lake, and improving the technical specifications. It also provide references for investigating Chinese Materia Medica resources survey on similar ecological environment under the condition of artificial intervention. Copyright© by the Chinese Pharmaceutical Association.
Selection biases in empirical p(z) methods for weak lensing
Gruen, D.; Brimioulle, F.
2017-02-23
To measure the mass of foreground objects with weak gravitational lensing, one needs to estimate the redshift distribution of lensed background sources. This is commonly done in an empirical fashion, i.e. with a reference sample of galaxies of known spectroscopic redshift, matched to the source population. In this paper, we develop a simple decision tree framework that, under the ideal conditions of a large, purely magnitude-limited reference sample, allows an unbiased recovery of the source redshift probability density function p(z), as a function of magnitude and colour. We use this framework to quantify biases in empirically estimated p(z) caused bymore » selection effects present in realistic reference and weak lensing source catalogues, namely (1) complex selection of reference objects by the targeting strategy and success rate of existing spectroscopic surveys and (2) selection of background sources by the success of object detection and shape measurement at low signal to noise. For intermediate-to-high redshift clusters, and for depths and filter combinations appropriate for ongoing lensing surveys, we find that (1) spectroscopic selection can cause biases above the 10 per cent level, which can be reduced to ≈5 per cent by optimal lensing weighting, while (2) selection effects in the shape catalogue bias mass estimates at or below the 2 per cent level. Finally, this illustrates the importance of completeness of the reference catalogues for empirical redshift estimation.« less
Distribution of Pb-210 in Spanish Soils: Study of the Atmospheric Contribution
DOE Office of Scientific and Technical Information (OSTI.GOV)
Barrera, M.; Romero, M. L.; Valino, F.
The vertical distribution of activity and inventories of atmospheric Pb-210 is being studied in Spanish soils, aiming to establish the reference levels in the zone, based on the type of soil and the annual rainfall. A homogeneous distribution grid (approx. 150x150 km each cell) has been established covering the peninsular land, trying to combine the varying soil types (remaining undisturbed for the last 50 years) and the closeness to meteorological stations. Sampling has been performed by extracting undisturbed soil cylinders of 6 cm diameter and 120 cm length, with an impact penetrometer, and the soil cores have been sectioned inmore » slices of 3 cm thick. The analysis of Pb-210 has been performed using a gamma spectrometry system with coaxial HPGe detector sensitive at low energies (46.5 keV emission). The geometry of measured samples is thin enough (approx. 2 cm) to minimize self-absorption corrections. The work presents the results obtained so far. The Pb-210 activity profiles exhibit the characteristic decreasing shape with depth, showing maximum levels at the surface, and reaching the equilibrium activity with Ra-226 at a maximum depth depending on different environmental conditions. The unsupported Pb-210 inventory values are in the usual range (1000-5000 Bq/m{sup 2}), showing a positive correlation with the averaged annual rainfall. These reference levels could be used in posterior studies of anthropogenic alteration of soils, evaluation of erosion and desertification processes.« less
The γ-ray angular distribution in fast neutron inelastic scattering from iron
NASA Astrophysics Data System (ADS)
Beyer, Roland; Dietz, Mirco; Bemmerer, Daniel; Junghans, Arnd R.; Kögler, Toni; Massarczyk, Ralph; Müller, Stefan; Schmidt, Konrad; Schwengner, Ronald; Szücs, Tamás; Takács, Marcell P.; Wagner, Andreas
2018-04-01
The angular distribution of γ-rays emitted after inelastic scattering of fast neutrons from iron was determined at the n ELBE neutron time-of-flight facility. An iron sample of natural isotopic composition was irradiated by a continuous photo-neutron spectrum in the energy range from about 0.1 up to 10 MeV. The de-excitation γ-rays of the four lowest excited states of 56Fe and the first excited state of 54Fe were detected using a setup of five high-purity germanium (HPGe) detectors and five LaBr3 scintillation detectors positioned around the sample at 30°, 55°, 90°, 125° and 150° with respect to the incoming neutron beam. The resulting angular distributions were fitted by Legendre polynomials up to 4th order and the angular distribution coefficients a2 and a4 were extracted. The angular distribution coefficients of three transitions in 56Fe are reported here for the first time. The results are applied to a previous measurement of the inelastic scattering cross section determined using a single HPGe detector positioned at 125°. Using the updated γ-ray angular distribution, the previous cross section results are in good agreement with reference data.
NASA Astrophysics Data System (ADS)
von der Linden, Wolfgang; Dose, Volker; von Toussaint, Udo
2014-06-01
Preface; Part I. Introduction: 1. The meaning of probability; 2. Basic definitions; 3. Bayesian inference; 4. Combinatrics; 5. Random walks; 6. Limit theorems; 7. Continuous distributions; 8. The central limit theorem; 9. Poisson processes and waiting times; Part II. Assigning Probabilities: 10. Transformation invariance; 11. Maximum entropy; 12. Qualified maximum entropy; 13. Global smoothness; Part III. Parameter Estimation: 14. Bayesian parameter estimation; 15. Frequentist parameter estimation; 16. The Cramer-Rao inequality; Part IV. Testing Hypotheses: 17. The Bayesian way; 18. The frequentist way; 19. Sampling distributions; 20. Bayesian vs frequentist hypothesis tests; Part V. Real World Applications: 21. Regression; 22. Inconsistent data; 23. Unrecognized signal contributions; 24. Change point problems; 25. Function estimation; 26. Integral equations; 27. Model selection; 28. Bayesian experimental design; Part VI. Probabilistic Numerical Techniques: 29. Numerical integration; 30. Monte Carlo methods; 31. Nested sampling; Appendixes; References; Index.
Instruction manual for U.S. Geological Survey sediment observers
Johnson, Gary P.
1997-01-01
This instruction manual is intended for use by U.S. Geological Survey (USGS) Sediment Observers. An overview of the USGS Sediment Program is presented, and basic theory on sediment transport is explained. Step-by-step instructions on when and how to sample for sediment also are presented. USGS Sediment Observer safety issues are discussed and corrective actions are presented. An empty pouch is included at the back of the manual for miscellaneous supplies, such as extra sampler nozzles, thermometers, new gaskets, and markers to be supplied by USGS personnel distributing the manual. A plastic reference card also is included, which can be removed from the manual and kept at the sampling site. Only general guidelines are presented in the manual so space is provided for USGS personnel distributing the manual to fill in project specific instructions.
Zhu, Shanyou; Zhang, Hailong; Liu, Ronggao; Cao, Yun; Zhang, Guixin
2014-01-01
Sampling designs are commonly used to estimate deforestation over large areas, but comparisons between different sampling strategies are required. Using PRODES deforestation data as a reference, deforestation in the state of Mato Grosso in Brazil from 2005 to 2006 is evaluated using Landsat imagery and a nearly synchronous MODIS dataset. The MODIS-derived deforestation is used to assist in sampling and extrapolation. Three sampling designs are compared according to the estimated deforestation of the entire study area based on simple extrapolation and linear regression models. The results show that stratified sampling for strata construction and sample allocation using the MODIS-derived deforestation hotspots provided more precise estimations than simple random and systematic sampling. Moreover, the relationship between the MODIS-derived and TM-derived deforestation provides a precise estimate of the total deforestation area as well as the distribution of deforestation in each block.
Zhu, Shanyou; Zhang, Hailong; Liu, Ronggao; Cao, Yun; Zhang, Guixin
2014-01-01
Sampling designs are commonly used to estimate deforestation over large areas, but comparisons between different sampling strategies are required. Using PRODES deforestation data as a reference, deforestation in the state of Mato Grosso in Brazil from 2005 to 2006 is evaluated using Landsat imagery and a nearly synchronous MODIS dataset. The MODIS-derived deforestation is used to assist in sampling and extrapolation. Three sampling designs are compared according to the estimated deforestation of the entire study area based on simple extrapolation and linear regression models. The results show that stratified sampling for strata construction and sample allocation using the MODIS-derived deforestation hotspots provided more precise estimations than simple random and systematic sampling. Moreover, the relationship between the MODIS-derived and TM-derived deforestation provides a precise estimate of the total deforestation area as well as the distribution of deforestation in each block. PMID:25258742
Low-temperature positron annihilation study of B+-ion implanted PMMA
NASA Astrophysics Data System (ADS)
Kavetskyy, T. S.; Tsmots, V. M.; Voloshanska, S. Ya.; Šauša, O.; Nuzhdin, V. I.; Valeev, V. F.; Osin, Y. N.; Stepanov, A. L.
2014-08-01
Temperature dependent positron annihilation lifetime spectroscopy (PALS) measurements in the range of 50-300 K are carried out to study positronium formation in 40 KeV B+-ion implanted polymethylmethacrylate (B:PMMA) with two ion doses of 3.13 × 1015 and 3.75 × 1016 ions/cm2. The investigated samples show the various temperature trends of ortho-positronium (o-Ps) lifetime τ3 and intensity I3 in PMMA before and after ion implantation. Two transitions in the vicinity of ˜150 and ˜250 K, ascribed to γ and β transitions, respectively, are observed in the PMMA and B:PMMA samples in consistent with reference data for pristine sample. The obtained results are compared with room temperature PALS study of PMMA with different molecular weight (Mw) which known from literature. It is found that B+-ion implantation leads to decreasing Mw in PMMA at lower ion dose. At higher ion dose the local destruction of polymeric structure follows to broadening of lifetime distribution (hole size distribution).
Laser ablation in analytical chemistry - A review
DOE Office of Scientific and Technical Information (OSTI.GOV)
Russo, Richard E.; Mao, Xianglei; Liu, Haichen
Laser ablation is becoming a dominant technology for direct solid sampling in analytical chemistry. Laser ablation refers to the process in which an intense burst of energy delivered by a short laser pulse is used to sample (remove a portion of) a material. The advantages of laser ablation chemical analysis include direct characterization of solids, no chemical procedures for dissolution, reduced risk of contamination or sample loss, analysis of very small samples not separable for solution analysis, and determination of spatial distributions of elemental composition. This review describes recent research to understand and utilize laser ablation for direct solid sampling,more » with emphasis on sample introduction to an inductively coupled plasma (ICP). Current research related to contemporary experimental systems, calibration and optimization, and fractionation is discussed, with a summary of applications in several areas.« less
Self-referred whole-body CT imaging: current implications for health care consumers.
Illes, Judy; Fan, Ellen; Koenig, Barbara A; Raffin, Thomas A; Kann, Dylan; Atlas, Scott W
2003-08-01
To conduct an empirical analysis of self-referred whole-body computed tomography (CT) and develop a profile of the geographic and demographic distribution of centers, types of services and modalities, costs, and procedures for reporting results. An analysis was conducted of Web sites for imaging centers accepting self-referred patients identified by two widely used Internet search engines with large indexes. These Web sites were analyzed for geographic location, type of screening center, services, costs, and procedures for managing imaging results. Demographic data were extrapolated for analysis on the basis of center location. Descriptive statistics, such as frequencies, means, SDs, ranges, and CIs, were generated to describe the characteristics of the samples. Data were compared with national norms by using a distribution-free method for calculating a 95% CI (P <.05) for the median. Eighty-eight centers identified with the search methods were widely distributed across the United States, with a concentration on both coasts. Demographic analysis further situated them in areas of the country characterized by a population that consisted largely of European Americans (P <.05) and individuals of higher education (P <.05) and socioeconomic status (P <.05). Forty-seven centers offered whole-body screening; heart and lung examinations were most frequently offered. Procedures for reporting results were highly variable. The geographic distribution of the centers suggests target populations of educated health-conscious consumers who can assume high out-of-pocket costs. Guidelines developed from within the profession and further research are needed to ensure that benefits of these services outweigh risks to individuals and the health care system. Copyright RSNA, 2003.
Age-dependent biochemical quantities: an approach for calculating reference intervals.
Bjerner, J
2007-01-01
A parametric method is often preferred when calculating reference intervals for biochemical quantities, as non-parametric methods are less efficient and require more observations/study subjects. Parametric methods are complicated, however, because of three commonly encountered features. First, biochemical quantities seldom display a Gaussian distribution, and there must either be a transformation procedure to obtain such a distribution or a more complex distribution has to be used. Second, biochemical quantities are often dependent on a continuous covariate, exemplified by rising serum concentrations of MUC1 (episialin, CA15.3) with increasing age. Third, outliers often exert substantial influence on parametric estimations and therefore need to be excluded before calculations are made. The International Federation of Clinical Chemistry (IFCC) currently recommends that confidence intervals be calculated for the reference centiles obtained. However, common statistical packages allowing for the adjustment of a continuous covariate do not make this calculation. In the method described in the current study, Tukey's fence is used to eliminate outliers and two-stage transformations (modulus-exponential-normal) in order to render Gaussian distributions. Fractional polynomials are employed to model functions for mean and standard deviations dependent on a covariate, and the model is selected by maximum likelihood. Confidence intervals are calculated for the fitted centiles by combining parameter estimation and sampling uncertainties. Finally, the elimination of outliers was made dependent on covariates by reiteration. Though a good knowledge of statistical theory is needed when performing the analysis, the current method is rewarding because the results are of practical use in patient care.
Mercury Slovenian soils: High, medium and low sample density geochemical maps
NASA Astrophysics Data System (ADS)
Gosar, Mateja; Šajn, Robert; Teršič, Tamara
2017-04-01
Regional geochemical survey was conducted in whole territory of Slovenia (20273 km2). High, medium and low sample density surveys were compared. High sample density represented the regional geochemical data set supplemented by local high-density sampling data (irregular grid, n=2835). Medium-density soil sampling was performed in a 5 x 5 km grid (n=817) and low-density geochemical survey was conducted in a sampling grid 25 x 25 km (n=54). Mercury distribution in Slovenian soils was determined with models of mercury distribution in soil using all three data sets. A distinct Hg anomaly in western part of Slovenia is evident on all three models. It is a consequence of 500-years of mining and ore processing in the second largest mercury mine in the world, the Idrija mine. The determined mercury concentrations revealed an important difference between the western and the eastern parts of the country. For the medium scale geochemical mapping is the median value (0.151 mg /kg) for western Slovenia almost 2-fold higher than the median value (0.083 mg/kg) in eastern Slovenia. Besides the Hg median for the western part of Slovenia exceeds the Hg median for European soil by a factor of 4 (Gosar et al., 2016). Comparing these sample density surveys, it was shown that high sampling density allows the identification and characterization of anthropogenic influences on a local scale, while medium- and low-density sampling reveal general trends in the mercury spatial distribution, but are not appropriate for identifying local contamination in industrial regions and urban areas. The resolution of the pattern generated is the best when the high-density survey on a regional scale is supplemented with the geochemical data of the high-density surveys on a local scale. References: Gosar, M, Šajn, R, Teršič, T. Distribution pattern of mercury in the Slovenian soil: geochemical mapping based on multiple geochemical datasets. Journal of geochemical exploration, 2016, 167/38-48.
Curating NASA's Future Extraterrestrial Sample Collections: How Do We Achieve Maximum Proficiency?
NASA Technical Reports Server (NTRS)
McCubbin, Francis; Evans, Cynthia; Zeigler, Ryan; Allton, Judith; Fries, Marc; Righter, Kevin; Zolensky, Michael
2016-01-01
The Astromaterials Acquisition and Curation Office (henceforth referred to herein as NASA Curation Office) at NASA Johnson Space Center (JSC) is responsible for curating all of NASA's extraterrestrial samples. Under the governing document, NASA Policy Directive (NPD) 7100.10E "Curation of Extraterrestrial Materials", JSC is charged with "The curation of all extraterrestrial material under NASA control, including future NASA missions." The Directive goes on to define Curation as including "... documentation, preservation, preparation, and distribution of samples for research, education, and public outreach." Here we describe some of the ongoing efforts to ensure that the future activities of the NASA Curation Office are working towards a state of maximum proficiency.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cobb, G.P.; Wood, P.D.; O`Quinn, M.
1995-12-31
Investigation of contaminant burdens in threatened and endangered species is difficult due to the small number of samples that can be collected. Many samples can be collected if the sampling methods are non-lethal and more specifically non-invasive. Analysis of chorioallantoic membranes is demonstrated for American alligators and Loggerhead sea turtles. Significant differences were found in PCB, uptake by alligators from the Ashepoo-Combahee-Edisto Basin reference site and a contaminated site in Winyah Bay. Intrasite and intersite differences in uptake and distribution of PCB homologues were noted. These data will be discussed as they relate to egg viability and embryo development.
Pace, M.N.; Rosentreter, J.J.; Bartholomay, R.C.
2001-01-01
Idaho State University and the US Geological Survey, in cooperation with the US Department of Energy, conducted a study to determine and evaluate strontium distribution coefficients (Kds) of subsurface materials at the Idaho National Engineering and Environmental Laboratory (INEEL). The Kds were determined to aid in assessing the variability of strontium Kds and their effects on chemical transport of strontium-90 in the Snake River Plain aquifer system. Data from batch experiments done to determine strontium Kds of five sediment-infill samples and six standard reference material samples were analyzed by using multiple linear regression analysis and the stepwise variable-selection method in the statistical program, Statistical Product and Service Solutions, to derive an equation of variables that can be used to predict strontium Kds of sediment-infill samples. The sediment-infill samples were from basalt vesicles and fractures from a selected core at the INEEL; strontium Kds ranged from ???201 to 356 ml g-1. The standard material samples consisted of clay minerals and calcite. The statistical analyses of the batch-experiment results showed that the amount of strontium in the initial solution, the amount of manganese oxide in the sample material, and the amount of potassium in the initial solution are the most important variables in predicting strontium Kds of sediment-infill samples.
Durejko, Tomasz; Aniszewska, Justyna; Ziętala, Michał; Antolak-Dudka, Anna; Czujko, Tomasz; Varin, Robert A; Paserin, Vlad
2018-05-18
The water-atomized ATOMET 28, 1001, 4701, and 4801 powders, manufactured by Rio Tinto Metal Powders, were used for additive manufacturing by a laser engineered net shaping (LENS) technique. Their overall morphology was globular and rounded with a size distribution from about 20 to 200 µm. Only the ATOMET 28 powder was characterized by a strong inhomogeneity of particle size and irregular polyhedral shape of powder particles with sharp edges. The powders were pre-sieved to a size distribution from 40 to 150 µm before LENS processing. One particular sample-LENS-fabricated from the ATOMET 28 powder-was characterized by the largest cross-sectional (2D) porosity of 4.2% and bulk porosity of 3.9%, the latter determined by microtomography measurements. In contrast, the cross-sectional porosities of bulk, solid, nearly cubic LENS-fabricated samples from the other ATOMET powders exhibited very low porosities within the range 0.03⁻0.1%. Unexpectedly, the solid sample-LENS-fabricated from the reference, a purely spherical Fe 99.8 powder-exhibited a porosity of 1.1%, the second largest after that of the pre-sieved, nonspherical ATOMET 28 powder. Vibrations incorporated mechanically into the LENS powder feeding system substantially improved the flow rate vs. feeding rate dependence, making it completely linear with an excellent coefficient of fit, R² = 0.99. In comparison, the reference powder Fe 99.8 always exhibited a linear dependence of the powder flow rate vs. feeding rate, regardless of vibrations.
An Assessment of Drug Education-Prevention Programs in the U.S. Army
1975-01-01
education program at one post. In addition, group interviews were conducted with a total of 191 enlisted men. Both the survey data and the pretest ...with Drug Education Effects of Education on Drug Use Pretest - Posttest Results Interview Results DISCUSSION REFERENCES DISTRIBUTION LIST Page...evaluated by means of a separate-sample pretest - posttest design, using 220 subjects.8 In addition, group Interviews were conducted with randomly
Factors Influencing Temperature Fields during Combustion Reactions
2014-05-20
promoting thermal energy distributions. Keywords: Thermites · Nanoparticle combustion • Aluminum · Infrared thermometry • Non-ideal explosives 1...materials (nano- thermite ) comprised of a metallic fuel and organic or metal- lic oxidizer and will be referred to as nanothermites hence forth. The most...magnesium (Mg), manganese (Mn), and titanium (Ti) nanoparticles were added to Al/CuO at 10% by weight of the nanothermite sample. The nano- thermites with
Andreasen, C B; Pearson, E G; Smith, B B; Gerros, T C; Lassen, E D
1998-04-01
Fifty clinically healthy llamas, 0.5-13 years of age (22 intact males, 10 neutered males, 18 females), with no biochemical evidence of liver disease or hematologic abnormalities, were selected to establish serum bile acid reference intervals. Serum samples submitted to the clinical pathology laboratory were analyzed using a colorimetric enzymatic assay to establish bile acid reference intervals. A nonparametric distribution of llama bile acid concentrations was 1-23 micromol/liter for llamas >1 year of age and 10-44 micromol/liter for llamas < or = 1 year of age. A significant difference was found between these 2 age groups. No correlation was detected between gender and bile acid concentrations. The reference intervals were 1.1-22.9 micromol/liter for llamas >1 year of age and 1.8-49.8 micromol/liter for llamas < or = 1 year of age. Additionally, a separate group of 10 healthy adult llamas (5 males, 5 females, 5-11 years of age) without biochemical or hematologic abnormalities was selected to assess the effects of feeding and time intervals on serum bile acid concentrations. These 10 llamas were provided fresh water and hay ad libitum, and serum samples were obtained via an indwelling jugular catheter hourly for 11 hours. Llamas were then kept from food overnight (12 hours), and subsequent samples were taken prior to feeding (fasting baseline time, 23 hours after trial initiation) and postprandially at 0.5, 1, 2, 4, and 8 hours. In feeding trials, there was no consistent interaction between bile acid concentrations and time, feeding, or 12-hour fasting. Prior feeding or time of day did not result in serum bile acid concentrations outside the reference interval, but concentrations from individual llamas varied within this interval over time.
Koerbin, Gus; Tate, Jill; Potter, Julia M; Cavanaugh, Juleen; Glasgow, Nicholas; Hickman, Peter E
2012-02-03
Abbott Diagnostics have developed a new highly sensitive troponin I (hs-TnI) assay. We have assessed its analytical characteristics and applied the assay to a population of apparently cardio-healthy persons. We assessed imprecision, bias compared to the previous generation assay, matrix effects, and interferences and applied the assay to an apparently healthy population, deriving the 99th percentile limit of the distribution of values in reference populations for men and women separately. The dynamic range of the assay was ranged from 0.5-50,000 ng/L (pg/mL). The 10% CV was at a concentration of 3.9 ng/L, and the 20% CV was at a concentration of 1.8 ng/L. The new and current version of the TnI assay were highly correlated [slope: 0.98 (95%CI:0.88-1.07), y-intercept:1.20 (95%CI:-2.35-4.75) r²=0.99]. The 99th percentile limit of the distribution of values in a reference population was different for males and females: for males 14.0 ng/L and for females 11.1 ng/L and at these concentrations the assay CV was 5.0%. TnI was detectable in nearly all patient samples from the healthy reference population (98.6%). This new hs-TnI assay is able to measure to an order of magnitude lower than the current generation TnI assay from the same manufacturer. With TnI being detectable in nearly all apparently healthy subject samples this suggests that TnI presence does not always indicate cardiomyocyte necrosis.
An expanded mammal mitogenome dataset from Southeast Asia
Ramos-Madrigal, Jazmín; Peñaloza, Fernando; Liu, Shanlin; Mikkel-Holger, S. Sinding; Riddhi, P. Patel; Martins, Renata; Lenz, Dorina; Fickel, Jörns; Roos, Christian; Shamsir, Mohd Shahir; Azman, Mohammad Shahfiz; Burton, K. Lim; Stephen, J. Rossiter; Wilting, Andreas
2017-01-01
Abstract Southeast (SE) Asia is 1 of the most biodiverse regions in the world, and it holds approximately 20% of all mammal species. Despite this, the majority of SE Asia's genetic diversity is still poorly characterized. The growing interest in using environmental DNA to assess and monitor SE Asian species, in particular threatened mammals—has created the urgent need to expand the available reference database of mitochondrial barcode and complete mitogenome sequences. We have partially addressed this need by generating 72 new mitogenome sequences reconstructed from DNA isolated from a range of historical and modern tissue samples. Approximately 55 gigabases of raw sequence were generated. From this data, we assembled 72 complete mitogenome sequences, with an average depth of coverage of ×102.9 and ×55.2 for modern samples and historical samples, respectively. This dataset represents 52 species, of which 30 species had no previous mitogenome data available. The mitogenomes were geotagged to their sampling location, where known, to display a detailed geographical distribution of the species. Our new database of 52 taxa will strongly enhance the utility of environmental DNA approaches for monitoring mammals in SE Asia as it greatly increases the likelihoods that identification of metabarcoding sequencing reads can be assigned to reference sequences. This magnifies the confidence in species detections and thus allows more robust surveys and monitoring programmes of SE Asia's threatened mammal biodiversity. The extensive collections of historical samples from SE Asia in western and SE Asian museums should serve as additional valuable material to further enrich this reference database. PMID:28873965
An expanded mammal mitogenome dataset from Southeast Asia.
Mohd Salleh, Faezah; Ramos-Madrigal, Jazmín; Peñaloza, Fernando; Liu, Shanlin; Mikkel-Holger, S Sinding; Riddhi, P Patel; Martins, Renata; Lenz, Dorina; Fickel, Jörns; Roos, Christian; Shamsir, Mohd Shahir; Azman, Mohammad Shahfiz; Burton, K Lim; Stephen, J Rossiter; Wilting, Andreas; Gilbert, M Thomas P
2017-08-01
Southeast (SE) Asia is 1 of the most biodiverse regions in the world, and it holds approximately 20% of all mammal species. Despite this, the majority of SE Asia's genetic diversity is still poorly characterized. The growing interest in using environmental DNA to assess and monitor SE Asian species, in particular threatened mammals-has created the urgent need to expand the available reference database of mitochondrial barcode and complete mitogenome sequences. We have partially addressed this need by generating 72 new mitogenome sequences reconstructed from DNA isolated from a range of historical and modern tissue samples. Approximately 55 gigabases of raw sequence were generated. From this data, we assembled 72 complete mitogenome sequences, with an average depth of coverage of ×102.9 and ×55.2 for modern samples and historical samples, respectively. This dataset represents 52 species, of which 30 species had no previous mitogenome data available. The mitogenomes were geotagged to their sampling location, where known, to display a detailed geographical distribution of the species. Our new database of 52 taxa will strongly enhance the utility of environmental DNA approaches for monitoring mammals in SE Asia as it greatly increases the likelihoods that identification of metabarcoding sequencing reads can be assigned to reference sequences. This magnifies the confidence in species detections and thus allows more robust surveys and monitoring programmes of SE Asia's threatened mammal biodiversity. The extensive collections of historical samples from SE Asia in western and SE Asian museums should serve as additional valuable material to further enrich this reference database. © The Author 2017. Published by Oxford University Press.
Biological instability in a chlorinated drinking water distribution network.
Nescerecka, Alina; Rubulis, Janis; Vital, Marius; Juhna, Talis; Hammes, Frederik
2014-01-01
The purpose of a drinking water distribution system is to deliver drinking water to the consumer, preferably with the same quality as when it left the treatment plant. In this context, the maintenance of good microbiological quality is often referred to as biological stability, and the addition of sufficient chlorine residuals is regarded as one way to achieve this. The full-scale drinking water distribution system of Riga (Latvia) was investigated with respect to biological stability in chlorinated drinking water. Flow cytometric (FCM) intact cell concentrations, intracellular adenosine tri-phosphate (ATP), heterotrophic plate counts and residual chlorine measurements were performed to evaluate the drinking water quality and stability at 49 sampling points throughout the distribution network. Cell viability methods were compared and the importance of extracellular ATP measurements was examined as well. FCM intact cell concentrations varied from 5×10(3) cells mL(-1) to 4.66×10(5) cells mL(-1) in the network. While this parameter did not exceed 2.1×10(4) cells mL(-1) in the effluent from any water treatment plant, 50% of all the network samples contained more than 1.06×10(5) cells mL(-1). This indisputably demonstrates biological instability in this particular drinking water distribution system, which was ascribed to a loss of disinfectant residuals and concomitant bacterial growth. The study highlights the potential of using cultivation-independent methods for the assessment of chlorinated water samples. In addition, it underlines the complexity of full-scale drinking water distribution systems, and the resulting challenges to establish the causes of biological instability.
Biological Instability in a Chlorinated Drinking Water Distribution Network
Nescerecka, Alina; Rubulis, Janis; Vital, Marius; Juhna, Talis; Hammes, Frederik
2014-01-01
The purpose of a drinking water distribution system is to deliver drinking water to the consumer, preferably with the same quality as when it left the treatment plant. In this context, the maintenance of good microbiological quality is often referred to as biological stability, and the addition of sufficient chlorine residuals is regarded as one way to achieve this. The full-scale drinking water distribution system of Riga (Latvia) was investigated with respect to biological stability in chlorinated drinking water. Flow cytometric (FCM) intact cell concentrations, intracellular adenosine tri-phosphate (ATP), heterotrophic plate counts and residual chlorine measurements were performed to evaluate the drinking water quality and stability at 49 sampling points throughout the distribution network. Cell viability methods were compared and the importance of extracellular ATP measurements was examined as well. FCM intact cell concentrations varied from 5×103 cells mL−1 to 4.66×105 cells mL−1 in the network. While this parameter did not exceed 2.1×104 cells mL−1 in the effluent from any water treatment plant, 50% of all the network samples contained more than 1.06×105 cells mL−1. This indisputably demonstrates biological instability in this particular drinking water distribution system, which was ascribed to a loss of disinfectant residuals and concomitant bacterial growth. The study highlights the potential of using cultivation-independent methods for the assessment of chlorinated water samples. In addition, it underlines the complexity of full-scale drinking water distribution systems, and the resulting challenges to establish the causes of biological instability. PMID:24796923
Dudefoi, William; Terrisse, Hélène; Richard-Plouet, Mireille; Gautron, Eric; Popa, Florin; Humbert, Bernard; Ropers, Marie-Hélène
2017-05-01
Titanium dioxide (TiO 2 ) is a transition metal oxide widely used as a white pigment in various applications, including food. Due to the classification of TiO 2 nanoparticles by the International Agency for Research on Cancer as potentially harmful for humans by inhalation, the presence of nanoparticles in food products needed to be confirmed by a set of independent studies. Seven samples of food-grade TiO 2 (E171) were extensively characterised for their size distribution, crystallinity and surface properties by the currently recommended methods. All investigated E171 samples contained a fraction of nanoparticles, however, below the threshold defining the labelling of nanomaterial. On the basis of these results and a statistical analysis, E171 food-grade TiO 2 totally differs from the reference material P25, confirming the few published data on this kind of particle. Therefore, the reference material P25 does not appear to be the most suitable model to study the fate of food-grade TiO 2 in the gastrointestinal tract. The criteria currently to obtain a representative food-grade sample of TiO 2 are the following: (1) crystalline-phase anatase, (2) a powder with an isoelectric point very close to 4.1, (3) a fraction of nanoparticles comprised between 15% and 45%, and (4) a low specific surface area around 10 m 2 g - 1 .
Gil, F; Hernández, A F
2015-06-01
Human biomonitoring has become an important tool for the assessment of internal doses of metallic and metalloid elements. These elements are of great significance because of their toxic properties and wide distribution in environmental compartments. Although blood and urine are the most used and accepted matrices for human biomonitoring, other non-conventional samples (saliva, placenta, meconium, hair, nails, teeth, breast milk) may have practical advantages and would provide additional information on health risk. Nevertheless, the analysis of these compounds in biological matrices other than blood and urine has not yet been accepted as a useful tool for biomonitoring. The validation of analytical procedures is absolutely necessary for a proper implementation of non-conventional samples in biomonitoring programs. However, the lack of reliable and useful analytical methodologies to assess exposure to metallic elements, and the potential interference of external contamination and variation in biological features of non-conventional samples are important limitations for setting health-based reference values. The influence of potential confounding factors on metallic concentration should always be considered. More research is needed to ascertain whether or not non-conventional matrices offer definitive advantages over the traditional samples and to broaden the available database for establishing worldwide accepted reference values in non-exposed populations. Copyright © 2015 Elsevier Ltd. All rights reserved.
Rosende, Maria; Savonina, Elena Yu; Fedotov, Petr S; Miró, Manuel; Cerdà, Víctor; Wennrich, Rainer
2009-09-15
Dynamic fractionation has been recognized as an appealing alternative to conventional equilibrium-based sequential extraction procedures (SEPs) for partitioning of trace elements (TE) in environmental solid samples. This paper reports the first attempt for harmonization of flow-through dynamic fractionation using two novel methods, the so-called sequential injection microcolumn (SIMC) extraction and rotating coiled column (RCC) extraction. In SIMC extraction, a column packed with the solid sample is clustered in a sequential injection system, while in RCC, the particulate matter is retained under the action of centrifugal forces. In both methods, the leachants are continuously pumped through the solid substrates by the use of either peristaltic or syringe pumps. A five-step SEP was selected for partitioning of Cu, Pb and Zn in water soluble/exchangeable, acid-soluble, easily reducible, easily oxidizable and moderately reducible fractions from 0.2 to 0.5 g samples at an extractant flow rate of 1.0 mL min(-1) prior to leachate analysis by inductively coupled plasma-atomic emission spectrometry. Similarities and discrepancies between both dynamic approaches were ascertained by fractionation of TE in certified reference materials, namely, SRM 2711 Montana Soil and GBW 07311 sediment, and two real soil samples as well. Notwithstanding the different extraction conditions set by both methods, similar trends of metal distribution were in generally found. The most critical parameters for reliable assessment of mobilizable pools of TE in worse-case scenarios are the size-distribution of sample particles, the density of particles, the content of organic matter and the concentration of major elements. For reference materials and a soil rich in organic matter, the extraction in RCC results in slightly higher recoveries of environmentally relevant fractions of TE, whereas SIMC leaching is more effective for calcareous soils.
Using liver enzymes as screening tests to predict mortality risk.
Fulks, Michael; Stout, Robert L; Dolan, Vera F
2008-01-01
Determine the relationship between liver function test results (GGT, alkaline phosphatase, AST, and ALT) and all-cause mortality in life insurance applicants. By use of the Social Security Master Death File, mortality was examined in 1,905,664 insurance applicants for whom blood samples were submitted to the Clinical Reference Laboratory. There were 50,174 deaths observed in this study population. Results were stratified by 3 age/sex groups: females, age <60; males, age <60; and all, age 60+. Liver function test values were grouped using percentiles of their distribution in these 3 age/sex groups, as well as ranges of actual values. Using the risk of the middle 50% of the population by distribution as a reference, relative mortality observed for GGT and alkaline phosphatase was linear with a steep slope from very low to relatively high values. Relative mortality was increased at lower values for both AST and ALT. ALT did not predict mortality for values above the middle 50% of its distribution. GGT and alkaline phosphatase are significant predictors of mortality risk for all values. ALT is still useful for triggering further testing for hepatitis, but AST should be used instead to assess mortality risk linked with transaminases.
Coherent Frequency Reference System for the NASA Deep Space Network
NASA Technical Reports Server (NTRS)
Tucker, Blake C.; Lauf, John E.; Hamell, Robert L.; Gonzaler, Jorge, Jr.; Diener, William A.; Tjoelker, Robert L.
2010-01-01
The NASA Deep Space Network (DSN) requires state-of-the-art frequency references that are derived and distributed from very stable atomic frequency standards. A new Frequency Reference System (FRS) and Frequency Reference Distribution System (FRD) have been developed, which together replace the previous Coherent Reference Generator System (CRG). The FRS and FRD each provide new capabilities that significantly improve operability and reliability. The FRS allows for selection and switching between frequency standards, a flywheel capability (to avoid interruptions when switching frequency standards), and a frequency synthesis system (to generate standardized 5-, 10-, and 100-MHz reference signals). The FRS is powered by redundant, specially filtered, and sustainable power systems and includes a monitor and control capability for station operations to interact and control the frequency-standard selection process. The FRD receives the standardized 5-, 10-, and 100-MHz reference signals and distributes signals to distribution amplifiers in a fan out fashion to dozens of DSN users that require the highly stable reference signals. The FRD is also powered by redundant, specially filtered, and sustainable power systems. The new DSN Frequency Distribution System, which consists of the FRS and FRD systems described here, is central to all operational activities of the NASA DSN. The frequency generation and distribution system provides ultra-stable, coherent, and very low phase-noise references at 5, l0, and 100 MHz to between 60 and 100 separate users at each Deep Space Communications Complex.
Li, Aiwei; Yang, Shuo; Zhang, Jie; Qiao, Rui
2017-11-01
To observe the changes of complete blood count (CBC) parameters during pregnancy and establish appropriate reference intervals for healthy pregnant women. Healthy pregnant women took the blood tests at all trimesters. All blood samples were processed on Sysmex XE-2100. The following CBC parameters were analyzed: red blood cell count (RBC), hemoglobin (Hb), hematocrit (Hct), mean corpuscular volume (MCV), mean corpuscular hemoglobin (MCH), mean corpuscular hemoglobin concentration (MCHC), red blood cell distribution width (RDW), platelet count (PLT), mean platelet volume (MPV), platelet distribution width (PDW), white blood cell count (WBC), and leukocyte differential count. Reference intervals were established using the 2.5th and 97.5th percentile of the distribution. Complete blood count parameters showed dynamic changes during trimesters. RBC, Hb, Hct declined at trimester 1, reaching their lowest point at trimester 2, and began to rise again at trimester 3. WBC, neutrophil count (Neut), monocyte count (MONO), RDW, and PDW went up from trimester 1 to trimester 3. On the contrary, MCHC, lymphocyte count (LYMPH), PLT, and MPV gradually descended during pregnancy. There were statistical significances in all CBC parameters between pregnant women and normal women, regardless of the trimesters (P<.001). The median obtained were (normal vs pregnancy) as follows: RBC 4.50 vs 3.94×10 12 /L, Hb 137 vs 120 g/L, WBC 5.71 vs 9.06×10 9 /L, LYMPH% 32.2 vs 18.0, Neut% 58.7 vs 75.0, and PLT 251 vs 202×10 9 /L. The changes of CBC parameters during pregnancy are described, and reference intervals for Beijing pregnant women are demonstrated in this study. © 2017 Wiley Periodicals, Inc.
Temporal change in the size distribution of airborne Radiocesium derived from the Fukushima accident
NASA Astrophysics Data System (ADS)
Kaneyasu, Naoki; Ohashi, Hideo; Suzuki, Fumie; Okuda, Tomoaki; Ikemori, Fumikazu; Akata, Naofumi
2013-04-01
The accident of Fukushima Dai-ichi nuclear power plant discharged a large amount of radioactive materials into the environment. After 40 days of the accident, we started to collect the size-segregated aerosol at Tsukuba City, Japan, located 170 km south of the plant, by use of a low-pressure cascade impactor. The sampling continued from April 28, through October 26, 2011. The number of sample sets collected in total was 8. The radioactivity of 134Cs and 137Cs in aerosols collected at each stage were determined by gamma-ray with a high sensitivity Germanic detector. After the gamma-ray spectrometry analysis, the chemical species in the aerosols were analyzed. The analyses of first (April 28-May 12) and second (May 12-26) samples showed that the activity size distributions of 134Cs and 137Cs in aerosols reside mostly in the accumulation mode size range. These activity size distributions almost overlapped with the mass size distribution of non-sea-salt sulfate aerosol. From the results, we regarded that sulfate is the main transport medium of these radionuclides, and re-suspended soil particles that attached radionuclides were not the major airborne radioactive substances by the end of May, 2011 (Kaneyasu et al., 2012). We further conducted the successive extraction experiment of radiocesium from the aerosol deposits on the aluminum sheet substrate (8th stage of the first aerosol sample, 0.5-0.7 μm in aerodynamic diameter) with water and 0.1M HCl. In contrast to the relatively insoluble property of Chernobyl radionuclides, those in aerosols collected at Tsukuba in fine mode are completely water-soluble (100%). From the third aerosol sample, the activity size distributions started to change, i.e., the major peak in the accumulation mode size range seen in the first and second aerosol samples became smaller and an additional peak appeared in the coarse mode size range. The comparison of the activity size distributions of radiocesium and the mass size distributions of major aerosol components collected by the end of August, 2011, (i.e., sample No.5) and its implication will be discussed in the presentation. Reference Kaneyasu et al., Environ. Sci. Technol. 46, 5720-5726 (2012).
WAMS measurements pre-processing for detecting low-frequency oscillations in power systems
NASA Astrophysics Data System (ADS)
Kovalenko, P. Y.
2017-07-01
Processing the data received from measurement systems implies the situation when one or more registered values stand apart from the sample collection. These values are referred to as “outliers”. The processing results may be influenced significantly by the presence of those in the data sample under consideration. In order to ensure the accuracy of low-frequency oscillations detection in power systems the corresponding algorithm has been developed for the outliers detection and elimination. The algorithm is based on the concept of the irregular component of measurement signal. This component comprises measurement errors and is assumed to be Gauss-distributed random. The median filtering is employed to detect the values lying outside the range of the normally distributed measurement error on the basis of a 3σ criterion. The algorithm has been validated involving simulated signals and WAMS data as well.
dos Santos, Sabrina Novaes; Alleoni, Luís Reynaldo Ferracciú
2013-07-01
Guideline values are used to identify polluted or contaminated areas based on background values. Brazilian law establishes three guideline values for pollutants: a quality reference value (QRV), a prevention value, and an intervention value. Reference values refer to the natural concentration of an element or a substance in soils that have not been modified by anthropogenic impacts. These values inform assessments of soil quality and are used to establish maximum permissible limits. The objective of this study was to determine the natural levels and reference values for Cd, Co, Cr, Cu, Ni, Pb, and Zn in samples from the surface layer (0-20 cm) of 19 representative soils of the states of Mato Grosso and Rondônia, on Brazil's agricultural frontier. Pseudo-total metal concentrations were obtained following microwave-assisted digestion using the aqua regia and EPA3051 methods. QRVs were calculated for each element as the 75th and 90th percentiles of the frequency distribution of the data. Natural levels of heavy metals in the soil samples followed the order: Cr > Zn > Cu > Co > Pb > Ni > and Cd (aqua regia) and Cr > Co > Cu > Pb > Zn > Ni > Cd (EPA3051). These values are generally lower than those reported in the Brazilian and international literature, which highlights the importance of establishing reference values for each state or for each soil type, taking into account the geomorphological, pedological, and geological diversity of the region under study.
Automated processing for proton spectroscopic imaging using water reference deconvolution.
Maudsley, A A; Wu, Z; Meyerhoff, D J; Weiner, M W
1994-06-01
Automated formation of MR spectroscopic images (MRSI) is necessary before routine application of these methods is possible for in vivo studies; however, this task is complicated by the presence of spatially dependent instrumental distortions and the complex nature of the MR spectrum. A data processing method is presented for completely automated formation of in vivo proton spectroscopic images, and applied for analysis of human brain metabolites. This procedure uses the water reference deconvolution method (G. A. Morris, J. Magn. Reson. 80, 547(1988)) to correct for line shape distortions caused by instrumental and sample characteristics, followed by parametric spectral analysis. Results for automated image formation were found to compare favorably with operator dependent spectral integration methods. While the water reference deconvolution processing was found to provide good correction of spatially dependent resonance frequency shifts, it was found to be susceptible to errors for correction of line shape distortions. These occur due to differences between the water reference and the metabolite distributions.
Hydroecological monitoring in the headwaters of the Volga River
NASA Astrophysics Data System (ADS)
Kuzovlev, Viacheslav V.; Zhenikov, Yuri N.; Zhenikov, Kyrill Y.; Shaporenko, Sergey I.; Haun, Stefan; Füreder, Leopold; Schletterer, Martin
2016-04-01
Europe's largest river, the Volga (3551 km), has experienced multiple stressors from human activities (i.e. the Volga Basin comprises about 40 % of the Russian population, 45 % of the country's industry and more than 50 % of its agriculture). During the research expedition "Upper Volga 2005" an assessment of hydrological, limnochemical and biological parameters was carried out by scientists from the Russian Federation and from Austria. The extensive sampling in 2005 showed that the free-flowing section of the Volga River, located upstream of Tver, represents conditions which are either reference or least disturbed - thus it can be considered as a refugial system for freshwater biota of the European lowlands. Subsequently three stretches in the headwaters of the Volga River (Rzhev, Staritsa, Tver) were selected for the monitoring programme "REFCOND_VOLGA", which is in operation since 2006. These locations correspond also with the sampling sites of ROSHYDROMET, i.e. at Tver physic-chemical samples are taken monthly and at Rzhev samples are taken in the main hydrological periods. The laboratory ship "ROSHYDROMET 11" conducted monthly cruises between Tver and Kalyazin (Ivankovskoye and Uglichskoye reservoirs on Volga) in the headwaters during the navigation period (May - October). This also includes measurements with ADCP, which further allow the analyses of the spatial distribution of the suspended solids within cross sections. In addition sediment fluxes were derived by using the acoustic backscatter signal strength from the acoustic current Doppler profiler (ADCP). We exemplify at the monitoring sites the spatial distribution of different sediments, i.e. choriotope types, according the longitudinal profile of the river. We show that it is highly influenced by morphodynamics in the different river sections and this corresponds with the zoobenthos fauna accordingly. This interdisciplinary approach, including sediment conditions, limnochemistry, hydrology and hydrobiology, leads to a hydro-ecological reference for European lowland rivers.
Cayuela, Jean-Michel; Mauté, Carole; Fabre, Anne-Lise; Nibourel, Olivier; Dulucq, Stéphanie; Delabesse, Eric; Villarèse, Patrick; Hayette, Sandrine; Mozziconacci, Marie-Joelle; Macintyre, Elizabeth
2015-10-01
Performance of methods used for molecular diagnostics must be closely controlled by regular analysis of internal quality controls. However, conditioning, shipping and long lasting storage of nucleic acid controls remain problematic. Therefore, we evaluated the minicapsule-based innovative process developed by Imagene (Evry, France) for implementing DNA and RNA controls designed for clonality assessment of lymphoproliferations and BCR-ABL1 mRNA quantification, respectively. DNA samples were extracted from 12 cell lines selected for giving specific amplifications with most BIOMED-2 PCR tubes. RNA samples were extracted from 8 cell line mixtures expressing various BCR-ABL1 transcript levels. DNA and RNA were encapsulated by Imagene and shipped at room temperature to participating laboratories. Biologists were asked to report quality data of recovered nucleic acids as well as PCR results. Encapsulated nucleic acids samples were easily and efficiently recovered from minicapsules. The expected rearrangements at immunoglobulin, T-cell receptor and BCL2 loci were detected in DNA samples by all laboratories. Quality of RNA was consistent between laboratories and met the criteria requested for quantification of BCR-ABL1 transcripts. Expression levels measured by the 5 laboratories were within ±2 fold interval from the corresponding pre-encapsulation reference value. Moreover aging studies of encapsulated RNA simulating up to 100 years storage at room temperature show no bias in quantitative outcome. Therefore, Imagene minicapsules are suitable for storage and distribution at room temperature of genetic material designed for proficiency control of molecular diagnostic methods based on end point or real-time quantitative PCR. Copyright © 2014 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
Molecular Identification of Commercialized Medicinal Plants in Southern Morocco
Krüger, Åsa; Rydberg, Anders; Abbad, Abdelaziz; Björk, Lars; Martin, Gary
2012-01-01
Background Medicinal plant trade is important for local livelihoods. However, many medicinal plants are difficult to identify when they are sold as roots, powders or bark. DNA barcoding involves using a short, agreed-upon region of a genome as a unique identifier for species– ideally, as a global standard. Research Question What is the functionality, efficacy and accuracy of the use of barcoding for identifying root material, using medicinal plant roots sold by herbalists in Marrakech, Morocco, as a test dataset. Methodology In total, 111 root samples were sequenced for four proposed barcode regions rpoC1, psbA-trnH, matK and ITS. Sequences were searched against a tailored reference database of Moroccan medicinal plants and their closest relatives using BLAST and Blastclust, and through inference of RAxML phylograms of the aligned market and reference samples. Principal Findings Sequencing success was high for rpoC1, psbA-trnH, and ITS, but low for matK. Searches using rpoC1 alone resulted in a number of ambiguous identifications, indicating insufficient DNA variation for accurate species-level identification. Combining rpoC1, psbA-trnH and ITS allowed the majority of the market samples to be identified to genus level. For a minority of the market samples, the barcoding identification differed significantly from previous hypotheses based on the vernacular names. Conclusions/Significance Endemic plant species are commercialized in Marrakech. Adulteration is common and this may indicate that the products are becoming locally endangered. Nevertheless the majority of the traded roots belong to species that are common and not known to be endangered. A significant conclusion from our results is that unknown samples are more difficult to identify than earlier suggested, especially if the reference sequences were obtained from different populations. A global barcoding database should therefore contain sequences from different populations of the same species to assure the reference sequences characterize the species throughout its distributional range. PMID:22761800
Ramsthaler, F; Kreutz, K; Verhoff, M A
2007-11-01
It has been generally accepted in skeletal sex determination that the use of metric methods is limited due to the population dependence of the multivariate algorithms. The aim of the study was to verify the applicability of software-based sex estimations outside the reference population group for which discriminant equations have been developed. We examined 98 skulls from recent forensic cases of known age, sex, and Caucasian ancestry from cranium collections in Frankfurt and Mainz (Germany) to determine the accuracy of sex determination using the statistical software solution Fordisc which derives its database and functions from the US American Forensic Database. In a comparison between metric analysis using Fordisc and morphological determination of sex, average accuracy for both sexes was 86 vs 94%, respectively, and males were identified more accurately than females. The ratio of the true test result rate to the false test result rate was not statistically different for the two methodological approaches at a significance level of 0.05 but was statistically different at a level of 0.10 (p=0.06). Possible explanations for this difference comprise different ancestry, age distribution, and socio-economic status compared to the Fordisc reference sample. It is likely that a discriminant function analysis on the basis of more similar European reference samples will lead to more valid and reliable sexing results. The use of Fordisc as a single method for the estimation of sex of recent skeletal remains in Europe cannot be recommended without additional morphological assessment and without a built-in software update based on modern European reference samples.
Statistical analyses to support guidelines for marine avian sampling. Final report
Kinlan, Brian P.; Zipkin, Elise; O'Connell, Allan F.; Caldow, Chris
2012-01-01
Interest in development of offshore renewable energy facilities has led to a need for high-quality, statistically robust information on marine wildlife distributions. A practical approach is described to estimate the amount of sampling effort required to have sufficient statistical power to identify species-specific “hotspots” and “coldspots” of marine bird abundance and occurrence in an offshore environment divided into discrete spatial units (e.g., lease blocks), where “hotspots” and “coldspots” are defined relative to a reference (e.g., regional) mean abundance and/or occurrence probability for each species of interest. For example, a location with average abundance or occurrence that is three times larger the mean (3x effect size) could be defined as a “hotspot,” and a location that is three times smaller than the mean (1/3x effect size) as a “coldspot.” The choice of the effect size used to define hot and coldspots will generally depend on a combination of ecological and regulatory considerations. A method is also developed for testing the statistical significance of possible hotspots and coldspots. Both methods are illustrated with historical seabird survey data from the USGS Avian Compendium Database. Our approach consists of five main components: 1. A review of the primary scientific literature on statistical modeling of animal group size and avian count data to develop a candidate set of statistical distributions that have been used or may be useful to model seabird counts. 2. Statistical power curves for one-sample, one-tailed Monte Carlo significance tests of differences of observed small-sample means from a specified reference distribution. These curves show the power to detect "hotspots" or "coldspots" of occurrence and abundance at a range of effect sizes, given assumptions which we discuss. 3. A model selection procedure, based on maximum likelihood fits of models in the candidate set, to determine an appropriate statistical distribution to describe counts of a given species in a particular region and season. 4. Using a large database of historical at-sea seabird survey data, we applied this technique to identify appropriate statistical distributions for modeling a variety of species, allowing the distribution to vary by season. For each species and season, we used the selected distribution to calculate and map retrospective statistical power to detect hotspots and coldspots, and map pvalues from Monte Carlo significance tests of hotspots and coldspots, in discrete lease blocks designated by the U.S. Department of Interior, Bureau of Ocean Energy Management (BOEM). 5. Because our definition of hotspots and coldspots does not explicitly include variability over time, we examine the relationship between the temporal scale of sampling and the proportion of variance captured in time series of key environmental correlates of marine bird abundance, as well as available marine bird abundance time series, and use these analyses to develop recommendations for the temporal distribution of sampling to adequately represent both shortterm and long-term variability. We conclude by presenting a schematic “decision tree” showing how this power analysis approach would fit in a general framework for avian survey design, and discuss implications of model assumptions and results. We discuss avenues for future development of this work, and recommendations for practical implementation in the context of siting and wildlife assessment for offshore renewable energy development projects.
Different strategies for spatial updating in yaw and pitch path integration
Goeke, Caspar M.; König, Peter; Gramann, Klaus
2013-01-01
Research in spatial navigation revealed the existence of discrete strategies defined by the use of distinct reference frames during virtual path integration. The present study investigated the distribution of these navigation strategies as a function of gender, video gaming experience, and self-estimates of spatial navigation abilities in a population of 300 subjects. Participants watched videos of virtual passages through a star-field with one turn in either the horizontal (yaw) or the vertical (pitch) axis. At the end of a passage they selected one out of four homing arrows to indicate the initial starting location. To solve the task, participants could employ two discrete strategies, navigating within either an egocentric or an allocentric reference frame. The majority of valid subjects (232/260) consistently used the same strategy in more than 75% of all trials. With that approach 33.1% of all participants were classified as Turners (using an egocentric reference frame on both axes) and 46.5% as Non-turners (using an allocentric reference frame on both axes). 9.2% of all participants consistently used an egocentric reference frame in the yaw plane but an allocentric reference frame in the pitch plane (Switcher). Investigating the influence of gender on navigation strategies revealed that females predominantly used the Non-turner strategy while males used both the Turner and the Non-turner strategy with comparable probabilities. Other than expected, video gaming experience did not influence strategy use. Based on a strong quantitative basis with the sample size about an order of magnitude larger than in typical psychophysical studies these results demonstrate that most people reliably use one out of three possible navigation strategies (Turners, Non-turners, Switchers) for spatial updating and provides a sound estimate of how those strategies are distributed within the general population. PMID:23412683
NASA Astrophysics Data System (ADS)
Zhang, F.; Can, N.; Hafiz, S.; Monavarian, M.; Das, S.; Avrutin, V.; Özgür, Ü.; Morkoç, H.
2015-05-01
The effect of δ-doping of In0.06Ga0.94N barriers with Mg on the quantum efficiency of blue light-emitting-diodes (LEDs) with active regions composed of 6 (hex) 3-nm In0.15Ga0.85N is investigated. Compared to the reference sample, δ-doping of the first barrier on the n-side of the LED structure improves the peak external quantum efficiency (EQE) by 20%, owing to the increased hole concentration in the wells adjacent to the n-side, as confirmed by numerical simulations of carrier distributions across the active region. Doping the second barrier, in addition to the first one, did not further enhance the EQE, which likely indicates compensation of improved hole injection by degradation of the active region quality due to Mg doping. Both LEDs with Mg δ-doped barriers effectively suppress the drop of efficiency at high injection when compared to the reference sample, and the onset of EQE peak roll-off shifts from ˜80 A/cm2 in the reference LED to ˜120 A/cm2 in the LEDs with Mg δ-doped barriers.
Klump, S P; Allred, M C; MacDonald, J L; Ballam, J M
2001-01-01
Isoflavones are biologically active compounds occurring naturally in a variety of plants, with relatively high levels found in soybeans. Twelve laboratories participated in a collaborative study to determine the aglycon isoflavone content of 8 test samples of soy and foods containing soy. The analytical method for the determination of isoflavones incorporates a mild saponification step that reduces the number of analytes measured and permits quantitation versus commercially available, stable reference standards. Test samples were extracted at 65 degrees C with methanol-water (80 + 20), saponified with dilute sodium hydroxide solution, and analyzed by reversed-phase liquid chromatography with UV detection at 260 nm. Isoflavone results were reported as microg/aglycon/g or microg aglycon equivalents/g. The 8 test samples included 2 blind duplicates and 4 single test samples with total isoflavone concentrations ranging from approximately 50 to 3000 microg/g. Test samples of soy ingredients and products made with soy were distributed to collaborators with appropriate reference standards. Collaborators were asked to analyze test samples in duplicate on 2 separate days. The data were analyzed for individual isoflavone components, subtotals of daidzin-daidzein, glycitin-glycitein, and genistin-genistein, and total isoflavones. The relative standard deviation (RSD) for repeatability was 1.8-7.1%, and the RSD for reproducibility was 3.2-16.1% for total isoflavone values of 47-3099 microg/g.
NASA Astrophysics Data System (ADS)
Wiesenberg, Guido; Hambach, Ulrich
2010-05-01
The well investigated Krems-Wachtberg excavation yielded a broad variety of anthropogenic artefacts and thus enables a proper reconstruction of an ancient settlement of Upper-Palaeolithic age. Despite these artefacts, some questions cannot be answered by sedimentologic and archaeologic approaches. Molecular fossils like lipids including aliphatic hydrocarbons are suitable to improve understanding of e.g. paleoclimatic, pedogenetic, and archaeologic contexts. Especially aliphatic hydrocarbons including straight-chain and branched alkanes yield potential to elucidate biogenic sources of soil and loess organic matter and to assess degradation conditions of primary organic matter. To improve understanding on the terms the fireplaces at the Krems-Wachtberg site are used, aliphatic hydrocarbons are investigated on a set of samples covering several horizons in the context of one fireplace, which was part of the excavation. Horizons above and below the fireplace as well as the fireplace itself were investigated for lipids. Additionally, reference loess samples from a similar age like the fireplace and a pit filling were investigated. Two replicates were available for most samples except for the pit filling. Two distinct fireplace series have been studies. All samples were extracted for lipids using Soxhlet extraction followed by column chromatography in order to separate the aliphatic hydrocarbon fraction from other lipids. Thereafter, aliphatic hydrocarbons were quantified using gas chromatography. The total amounts of extractable organic compounds in the whole sample set from the Krems-Wachtberg site were in the range of usual loess deposits and accounted for 30-80 mg kg-1 loess. The largest contents were observed in reference loess samples and decreased within the excavation from fireplaces > sediments covering fireplace > basement of fireplace > pit. The lower the extract yields, the stronger was the degradation of organic matter. In this context, the pit yielded either organic matter that was strongly degraded during rotting process of organic material after burial or incorporation of already strongly degraded organic matter like ash from fireplaces. The basement of the fireplace was exposed to high temperature for the whole usage of the place, resulting in a modification in the structure of the sediments and a degradation of organic matter within the sediments. The material from the fireplace itself probably was not completely burned and thus yielded comparatively large amounts of extractable components. The sediments covering the fireplace were potentially used to extinguish the fire and hence received a thermal alteration of the organic matter within the sediment under oxygen limiting conditions. Hence, the amount of extractable organic compounds can be used to reconstruct the firing process in the Krems-Wachtberg excavation. The amount of individual aliphatic hydrocarbons parallels the content of all extractable compounds and thus confirms the findings explained above. The aliphatic hydrocarbons reveal typical distribution patterns for grassland vegetation as indicated by a strong predomination of odd long chain alkanes and n-C31 as the most abundant homologue for most samples. Only sediments covering the fireplaces are dominated by n-C29 alkane. The different alkane distribution pattern for these sediments compared to all other samples including reference loess indicates a different biogenic source of the covering sediment than for all other samples. Probably, the covering sediments yield organic matter incorporated under forest or different grassland vegetation than the other sediments. In this study, several molecular markers have been tested for aliphatic hydrocarbons in order to elucidate their sources and to identify degradation effects responsible for the determined distribution patterns. The ratio of long chain vs. short chain alkanes enables the differentiation of plant-derived organic matter characterized by high ratios (>10) and organic matter derived from microbial biomass or degradation (<10). The reference loess samples were characterized by very high values (>50), which indicates plant biomass as the predominant source of loess organic matter. All other samples were characterized by low values (<10), which is due to degradation effects. Microbial alkanes as second potential source of short chain n-alkanes are not likely as odd homologues did not predominate over even homologues, which is typical for microbial alkanes. Furthermore even alkanes dominated in most samples, which can be related to thermal alteration of organic matter as common in fireplaces. Other degradation markers like n-alkanes vs. isoprenoid alkanes (n-C18/phytane) revealed values between 2-4.5. The fireplace samples were characterized by lowest values whereas the reference samples yielded highest values. Hence degradation increased from loess towards fireplace with an intermediate degradation of most other samples. Aliphatic hydrocarbon biomarkers like alkanes were found useful to reconstruct degradation intensity in ancient sediments and to elucidate anthropogenic activities like extinguishing of fire. Hence, organic geochemical investigations can be useful techniques to complement standard archaeological techniques.
Brand, Willi A.; Coplen, Tyler B.; Aerts-Bijma, Anita T.; Bohlke, John Karl; Gehre, Matthias; Geilmann, Heike; Groning, Manfred; Jansen, Henk G.; Meijer, Harro A. J.; Mroczkowski, Stanley J.; Qi, Haiping; Soergel, Karin; Stuart-Williams, Hilary; Weise, Stephan M.; Werner, Roland A.
2009-01-01
Internationally distributed organic and inorganic oxygen isotopic reference materials have been calibrated by six laboratories carrying out more than 5300 measurements using a variety of high-temperature conversion techniques (HTC) in an evaluation sponsored by the International Union of Pure and Applied Chemistry (IUPAC). To aid in the calibration of these reference materials, which span more than 125‰, an artificially enriched reference water (δ18O of +78.91‰) and two barium sulfates (one depleted and one enriched in 18O) were prepared and calibrated relative to VSMOW2 and SLAP reference waters. These materials were used to calibrate the other isotopic reference materials in this study, which yielded:Reference materialδ18O and estimated combined uncertainty IAEA-602 benzoic acid+71.28 ± 0.36‰USGS35 sodium nitrate+56.81 ± 0.31‰IAEA-NO-3 potassium nitrate+25.32 ± 0.29‰IAEA-601 benzoic acid+23.14 ± 0.19‰IAEA-SO-5 barium sulfate+12.13 ± 0.33‰NBS 127 barium sulfate+8.59 ± 0.26‰VSMOW2 water0‰IAEA-600 caffeine−3.48 ± 0.53‰IAEA-SO-6 barium sulfate−11.35 ± 0.31‰USGS34 potassium nitrate−27.78 ± 0.37‰SLAP water−55.5‰The seemingly large estimated combined uncertainties arise from differences in instrumentation and methodology and difficulty in accounting for all measurement bias. They are composed of the 3-fold standard errors directly calculated from the measurements and provision for systematic errors discussed in this paper. A primary conclusion of this study is that nitrate samples analyzed for δ18O should be analyzed with internationally distributed isotopic nitrates, and likewise for sulfates and organics. Authors reporting relative differences of oxygen-isotope ratios (δ18O) of nitrates, sulfates, or organic material should explicitly state in their reports the δ18O values of two or more internationally distributed nitrates (USGS34, IAEA-NO-3, and USGS35), sulfates (IAEA-SO-5, IAEA-SO-6, and NBS 127), or organic material (IAEA-601 benzoic acid, IAEA-602 benzoic acid, and IAEA-600 caffeine), as appropriate to the material being analyzed, had these reference materials been analyzed with unknowns. This procedure ensures that readers will be able to normalize the δ18O values at a later time should it become necessary.The high-temperature reduction technique for analyzing δ18O and δ2H is not as widely applicable as the well-established combustion technique for carbon and nitrogen stable isotope determination. To obtain the most reliable stable isotope data, materials should be treated in an identical fashion; within the same sequence of analyses, samples should be compared with working reference materials that are as similar in nature and in isotopic composition as feasible.
Jurowski, Kamil; Buszewski, Bogusław; Piekoszewski, Wojciech
2015-01-01
Nowadays, studies related to the distribution of metallic elements in biological samples are one of the most important issues. There are many articles dedicated to specific analytical atomic spectrometry techniques used for mapping/(bio)imaging the metallic elements in various kinds of biological samples. However, in such literature, there is a lack of articles dedicated to reviewing calibration strategies, and their problems, nomenclature, definitions, ways and methods used to obtain quantitative distribution maps. The aim of this article was to characterize the analytical calibration in the (bio)imaging/mapping of the metallic elements in biological samples including (1) nomenclature; (2) definitions, and (3) selected and sophisticated, examples of calibration strategies with analytical calibration procedures applied in the different analytical methods currently used to study an element's distribution in biological samples/materials such as LA ICP-MS, SIMS, EDS, XRF and others. The main emphasis was placed on the procedures and methodology of the analytical calibration strategy. Additionally, the aim of this work is to systematize the nomenclature for the calibration terms: analytical calibration, analytical calibration method, analytical calibration procedure and analytical calibration strategy. The authors also want to popularize the division of calibration methods that are different than those hitherto used. This article is the first work in literature that refers to and emphasizes many different and complex aspects of analytical calibration problems in studies related to (bio)imaging/mapping metallic elements in different kinds of biological samples. Copyright © 2014 Elsevier B.V. All rights reserved.
Marine anthropogenic radiotracers in the Southern Hemisphere: New sampling and analytical strategies
NASA Astrophysics Data System (ADS)
Levy, I.; Povinec, P. P.; Aoyama, M.; Hirose, K.; Sanchez-Cabeza, J. A.; Comanducci, J.-F.; Gastaud, J.; Eriksson, M.; Hamajima, Y.; Kim, C. S.; Komura, K.; Osvath, I.; Roos, P.; Yim, S. A.
2011-04-01
The Japan Agency for Marine Earth Science and Technology conducted in 2003-2004 the Blue Earth Global Expedition (BEAGLE2003) around the Southern Hemisphere Oceans, which was a rare opportunity to collect many seawater samples for anthropogenic radionuclide studies. We describe here sampling and analytical methodologies based on radiochemical separations of Cs and Pu from seawater, as well as radiometric and mass spectrometry measurements. Several laboratories took part in radionuclide analyses using different techniques. The intercomparison exercises and analyses of certified reference materials showed a reasonable agreement between the participating laboratories. The obtained data on the distribution of 137Cs and plutonium isotopes in seawater represent the most comprehensive results available for the Southern Hemisphere Oceans.
Søeby, Karen; Jensen, Peter Bjødstrup; Werge, Thomas; Sørensen, Steen
2015-09-01
The knowledge of physiological fluctuation and variation of even commonly used biochemical quantities in extreme age groups and during development is sparse. This challenges the clinical interpretation and utility of laboratory tests in these age groups. To explore the utility of hospital laboratory data as a source of information, we analyzed enzymatic plasma creatinine as a model analyte in two large pediatric hospital samples. Plasma creatinine measurements from 9700 children aged 0-18 years were obtained from hospital laboratory databases and partitioned into high-resolution gender- and age-groups. Normal probability plots were used to deduce parameters of the normal distributions from healthy creatinine values in the mixed hospital datasets. Furthermore, temporal trajectories were generated from repeated measurements to examine developmental patterns in periods of changing creatinine levels. Creatinine shows great age dependence from birth throughout childhood. We computed and replicated 95% reference intervals in narrow gender and age bins and showed them to be comparable to those determined in healthy population studies. We identified pronounced transitions in creatinine levels at different time points after birth and around the early teens, which challenges the establishment and usefulness of reference intervals in those age groups. The study documents that hospital laboratory data may inform on the developmental aspects of creatinine, on periods with pronounced heterogeneity and valid reference intervals. Furthermore, part of the heterogeneity in creatinine distribution is likely due to differences in biological and chronological age of children and should be considered when using age-specific reference intervals.
Aluminium-gold reference material for the k0-standardisation of neutron activation analysis
NASA Astrophysics Data System (ADS)
Ingelbrecht, C.; Peetermans, F.; De Corte, F.; De Wispelaere, A.; Vandecasteele, C.; Courtijn, E.; D'Hondt, P.
1991-05-01
Gold is an excellent comparator material for the k0-standardisation of neutron activation analysis because of its convenient and well defined nuclear properties. The most suitable form for a reference material is a dilute aluminium-gold alloy, for which the self-shielding effect for neutrons is small. Castings of composition Al-0.1 wt.% Au were prepared by crucible-less levitation melting, which gives close control of ingot composition with minimal contamination of the melt. The alloy composition was checked using induction-coupled plasma source emission spectrometry. The homogeneity of the alloy was measured by neutron activation analysis and a relative standard deviation of the gold content of 0.30% was found (10 mg samples). Metallography revealed a homogeneous distribution of AuAl 2 particles. The alloy was certified as Reference Material CBNM-530, with certified gold mass fraction 0.100±0.002 wt.%.
Molprobity's ultimate rotamer-library distributions for model validation.
Hintze, Bradley J; Lewis, Steven M; Richardson, Jane S; Richardson, David C
2016-09-01
Here we describe the updated MolProbity rotamer-library distributions derived from an order-of-magnitude larger and more stringently quality-filtered dataset of about 8000 (vs. 500) protein chains, and we explain the resulting changes and improvements to model validation as seen by users. To include only side-chains with satisfactory justification for their given conformation, we added residue-specific filters for electron-density value and model-to-density fit. The combined new protocol retains a million residues of data, while cleaning up false-positive noise in the multi- χ datapoint distributions. It enables unambiguous characterization of conformational clusters nearly 1000-fold less frequent than the most common ones. We describe examples of local interactions that favor these rare conformations, including the role of authentic covalent bond-angle deviations in enabling presumably strained side-chain conformations. Further, along with favored and outlier, an allowed category (0.3-2.0% occurrence in reference data) has been added, analogous to Ramachandran validation categories. The new rotamer distributions are used for current rotamer validation in MolProbity and PHENIX, and for rotamer choice in PHENIX model-building and refinement. The multi-dimensional χ distributions and Top8000 reference dataset are freely available on GitHub. These rotamers are termed "ultimate" because data sampling and quality are now fully adequate for this task, and also because we believe the future of conformational validation should integrate side-chain with backbone criteria. Proteins 2016; 84:1177-1189. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.
MolProbity’s Ultimate Rotamer-Library Distributions for Model Validation
Hintze, Bradley J.; Lewis, Steven M.; Richardson, Jane S.; Richardson, David C.
2016-01-01
Here we describe the updated MolProbity rotamer-library distributions derived from an order-of-magnitude larger and more stringently quality-filtered dataset of about 8000 (vs. 500) protein chains, and we explain the resulting changes and improvements to model validation as seen by users. To include only sidechains with satisfactory justification for their given conformation, we added residue-specific filters for electron-density value and model-to-density fit. The combined new protocol retains a million residues of data, while cleaning up false-positive noise in the multi-χ datapoint distributions. It enables unambiguous characterization of conformational clusters nearly 1000-fold less frequent than the most common ones. We describe examples of local interactions that favor these rare conformations, including the role of authentic covalent bond-angle deviations in enabling presumably strained sidechain conformations. Further, along with favored and outlier, an allowed category (0.3% to 2.0% occurrence in reference data) has been added, analogous to Ramachandran validation categories. The new rotamer distributions are used for current rotamer validation in Mol-Probity and PHENIX, and for rotamer choice in PHENIX model-building and refinement. The multi-dimensional χ distributions and Top8000 reference dataset are freely available on GitHub. These rotamers are termed “ultimate” because data sampling and quality are now fully adequate for this task, and also because we believe the future of conformational validation should integrate sidechain with backbone criteria. PMID:27018641
NASA Astrophysics Data System (ADS)
Changkit, N.; Boonkrongcheep, R.; Youngchauy, U.; Polthum, S.; Kessaratikoon, P.
2017-09-01
The specific activities of natural radionuclides (40K, 226Ra and 232Th) in 50 surface beach sand samples collected from Bangsaen beach in Chonburi province in the easthern region of Thailand, were measured and evaluated. Experimental results were obtained by using a high-purity germanium (HPGe) detector and gamma spectrometry analysis system in the special laboratory at Thailand Institute of Nuclear Technology (Public Organization). The IAEA-SOIL-375 reference material was used to analyze the concentration of 40K, 226Ra and 232Th in all samples. It was found that the specific activities of 40K, 226Ra and 232Th were ranged from 510.85 - 771.35, 8.17 - 17.06 and 4.25 - 15.68 Bq/kg. Furthermore, frequency distribution of the specific activities were studied, analyzed and found to be the asymmetrical distribution by using a statistical computer program. Moreover, four radiological hazard indices for the investigated area were also calculated by using the median values of specific activities of 40K, 226Ra and 232Th. The results were also compared with the Office of Atoms for Peace (OAP) annual report data, Thailand and global radioactivity measurement and evaluations.
Some scleractinian corals (Scleractinia: Anthozoa) of Larak Island, Persian Gulf.
Samiei, Jahangir Vajed; Dab, Koosha; Ghezellou, Parviz; Shirvani, Arash
2013-01-01
There is a shortage of knowledge about taxonomy and distribution of coral reef communities in the Persian Gulf. One of the main steps in the conservation and evaluation of such an environment is to locate and identify the communities and their inhabited fauna and flora. In the present study scleractinian corals were collected from depths of 3 to 9 meter around Larak Island, Persian Gulf. Underwater photographs of the sampled specimens were obtained in the natural habitat before sampling. 37 species have been identified via morphological characteristics of exoskeletons. The following study provided a pictorial reference to enhance the basic knowledge about coral reef communities in the Persian Gulf.
NASA Astrophysics Data System (ADS)
Starost, K.; Frijns, E.; Laer, J. V.; Faisal, N.; Egizabal, A.; Elizextea, C.; Nelissen, I.; Blazquez, M.; Njuguna, J.
2017-05-01
In this study, the effect on nanoparticle emissions due to drilling on Polypropylene (PP) reinforced with 20% talc, 5% montmorillonite (MMT) and 5% Wollastonite (WO) is investigated. The study is the first to explore the nanoparticle release from WO and talc reinforced composites and compares the results to previously researched MMT. With 5% WO, equivalent tensile properties with a 10 % weight reduction were obtained relative to the reference 20% talc sample. The materials were fabricated through injection moulding. The nanorelease studies were undertaken using the controlled drilling methodology for nanoparticle exposure assessment developed within the European Commission funded SIRENA Life 11 ENV/ES/506 project. Measurements were taken using CPC and DMS50 equipment for real-time characterization and measurements. The particle number concentration (of particles <1000nm) and particle size distribution (4.87nm - 562.34nm) of the particles emitted during drilling were evaluated to investigate the effect of the silicate fillers on the particles released. The nano-filled samples exhibited a 33% decrease (MMT sample) or a 30% increase (WO sample) on the average particle number concentration released in comparison to the neat polypropylene sample. The size distribution data displayed a substantial percentage of the particles released from the PP, PP/WO and PP/MMT samples to be between 5-20nm, whereas the PP/talc sample emitted larger particle diameters.
Lower white blood cell counts in elite athletes training for highly aerobic sports.
Horn, P L; Pyne, D B; Hopkins, W G; Barnes, C J
2010-11-01
White cell counts at rest might be lower in athletes participating in selected endurance-type sports. Here, we analysed blood tests of elite athletes collected over a 10-year period. Reference ranges were established for 14 female and 14 male sports involving 3,679 samples from 937 females and 4,654 samples from 1,310 males. Total white blood cell counts and counts of neutrophils, lymphocytes and monocytes were quantified. Each sport was scaled (1-5) for its perceived metabolic stress (aerobic-anaerobic) and mechanical stress (concentric-eccentric) by 13 sports physiologists. Substantially lower total white cell and neutrophil counts were observed in aerobic sports of cycling and triathlon (~16% of test results below the normal reference range) compared with team or skill-based sports such as water polo, cricket and volleyball. Mechanical stress of sports had less effect on the distribution of cell counts. The lower white cell counts in athletes in aerobic sports probably represent an adaptive response, not underlying pathology.
NASA Astrophysics Data System (ADS)
Valkiers, S.; Ding, T.; Inkret, M.; Ruße, K.; Taylor, P.
2005-04-01
A new 2 kg batch of SiO2 crystals, IRMM-018a as well as the existing NBS28 silica sand (or RM 8546, obtained by I. Friedman from U.S. Geological Survey) have been characterised for their "absolute" silicon isotope composition and molar mass. The amount-of-substance measurements needed for that purpose were performed on the IRMM amount comparator (Avogadro II) on samples from these batches, which were converted to gaseous silicon tetra-fluoride (SiF4). The isotope amount ratio measurements were calibrated by means of synthesized isotope amount ratios realized in the form of synthetic Si isotope mixtures, the measurement procedure of which makes them SI-traceable. IRMM-018a is intended to be used as Isotope Reference Material for isotope amount measurements in geochemical and other isotope abundance studies of silicon. It is distributed in samples of about 0.1 mol and will replace IRMM-018 (exhausted).
Vodovatov, A V; Balonov, M I; Golikov, V Yu; Shatsky, I G; Chipiga, L A; Bernhardsson, C
2017-04-01
In 2009-2014, dose surveys aimed to collect adult patient data and parameters of most common radiographic examinations were performed in six Russian regions. Typical patient doses were estimated for the selected examinations both in entrance surface dose and in effective dose. 75%-percentiles of typical patient effective dose distributions were proposed as preliminary regional diagnostic reference levels (DRLs) for radiography. Differences between the 75%-percentiles of regional typical patient dose distributions did not exceed 30-50% for the examinations with standardized clinical protocols (skull, chest and thoracic spine) and a factor of 1.5 for other examinations. Two different approaches for establishing national DRLs were evaluated: as a 75%-percentile of a pooled regional sample of patient typical doses (pooled method) and as a median of 75%-percentiles of regional typical patient dose distributions (median method). Differences between pooled and median methods for effective dose did not exceed 20%. It was proposed to establish Russian national DRLs in effective dose using a pooled method. In addition, the local authorities were granted an opportunity to establish regional DRLs if the local radiological practice and typical patient dose distributions are significantly different. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Malignant Tumors and Forensics – Dilemmas and Proposals
Budimlija, Zoran; Lu, Connie; Axler-DiPerte, Grace; Seifarth, Jessica; Popiolek, Dorota; Fogt, Franz; Prinz, Mechthild
2009-01-01
Aim To evaluate the effect of genetic instability and degradation in archived histology samples from cancerous tumors and to investigate the validity of short tandem repeat (STR) typing of these samples and its potential effect on human identification. Methods Two hundred and twenty eight slides of archival pathology tissues from 13 different types of malignant tumors were compared with healthy tissues from the same individuals. DNA analysis was performed using standard techniques for forensic STR analysis, PowerPlex®16 and Identifiler® on 2 distinct sample sets. Genetic instability was assessed by comparing reference tissues with cancerous tissues derived from the same individual. Loss of heterozygosity, a ≥50% reduction in heterozygosity ratio between healthy and diseased samples, and microsatellite instability, the presence of an additional allele not present in reference tissue, were assessed. The quality of profiles obtained with respect to completeness among the archived samples and degradation using the 2 platforms were also compared. Results Profiles obtained using the Identifiler® system were generally more complete, but showed 3-fold higher levels of instability (86%) than those obtained using PowerPlex® 16 (27%). Instances of genetic instability were distributed throughout all loci in both multiplex STR systems. Conclusion After having compared 2 widely used forensic chemistries, we suggest individual validation of each kit for use with samples likely to exhibit instability combined with fixation induced degradation or artifact. A “one size fits all” approach for interpretation of these samples among commercially available multiplexes is not recommended. PMID:19480018
Chiesa, Marco; Fonagy, Peter; Bateman, Anthony W
2007-12-01
Although several studies have described patient populations in primary care counselling settings and NHS (National Health Service) specialist psychotherapy settings, there is a paucity of studies specifically comparing differences in clinical characteristics between the two groups of patients. The aim of this study is to ascertain if specialist psychotherapy referrals represent a more challenging client group than primary care counselling patients. We compare the socio-demographic features and severity of presentation in the symptomatic, interpersonal problems and global adjustment dimensions of a sample of patients (N=384) assessed by a primary care counselling service located in North London and a sample of patients (N=853) assessed in eight NHS psychotherapy centres located within urban settings in England. Both the groups completed the Brief Symptom Inventory, the Inventory of Interpersonal Problems and Clinical Outcomes in Routine Evaluation Outcome Measure. Patients referred for specialist psychotherapy services were more dysfunctional than those referred for primary care counselling. The linear function constructed to discriminate the groups showed that a combination of more psychotic symptoms, social inhibitions and higher risk of self-harm effectively identified those referred to psychotherapy services, while patients exhibiting greater levels of somatic and anxiety symptoms and non-assertiveness were more likely to be seen in primary care settings. However, similarities between the two samples were also marked, as shown by the overlap in the distribution of clinical outcomes in routine evaluation clinical scores in the two samples. The findings are discussed in terms of their implications for policy and service delivery of these two types of psychological therapy services.
Multi-Sample Cluster Analysis Using Akaike’s Information Criterion.
1982-12-20
Intervals. For more details on these test procedures refer to Gabriel [7J, Krishnaiah (CIlUj, [11]), Srivastava [16), and others. -3- As noted in Consul...723. (4] Consul, P. C. (1969), "The Exact Distributions of Likelihood Criteria for Different Hypotheses," in P. R. Krishnaiah (Ed.), Multivariate...1178. [7] Gabriel, K. R. (1969), "A Comparison of Some lethods of Simultaneous Inference in MANOVA," in P. R. Krishnaiah (Ed.), Multivariate Analysis-lI
Till, J.L.; Jackson, M.J.; Rosenbaum, J.G.; Solheid, P.
2011-01-01
The Tiva Canyon Tuff contains dispersed nanoscale Fe-Ti-oxide grains with a narrow magnetic grain size distribution, making it an ideal material in which to identify and study grain-size-sensitive magnetic behavior in rocks. A detailed magnetic characterization was performed on samples from the basal 5 m of the tuff. The magnetic materials in this basal section consist primarily of (low-impurity) magnetite in the form of elongated submicron grains exsolved from volcanic glass. Magnetic properties studied include bulk magnetic susceptibility, frequency-dependent and temperature-dependent magnetic susceptibility, anhysteretic remanence acquisition, and hysteresis properties. The combined data constitute a distinct magnetic signature at each stratigraphic level in the section corresponding to different grain size distributions. The inferred magnetic domain state changes progressively upward from superparamagnetic grains near the base to particles with pseudo-single-domain or metastable single-domain characteristics near the top of the sampled section. Direct observations of magnetic grain size confirm that distinct transitions in room temperature magnetic susceptibility and remanence probably denote the limits of stable single-domain behavior in the section. These results provide a unique example of grain-size-dependent magnetic properties in noninteracting particle assemblages over three decades of grain size, including close approximations of ideal Stoner-Wohlfarth assemblages, and may be considered a useful reference for future rock magnetic studies involving grain-size-sensitive properties.
Estimation of effective temperatures in a quantum annealer: Towards deep learning applications
NASA Astrophysics Data System (ADS)
Realpe-Gómez, John; Benedetti, Marcello; Perdomo-Ortiz, Alejandro
Sampling is at the core of deep learning and more general machine learning applications; an increase in its efficiency would have a significant impact across several domains. Recently, quantum annealers have been proposed as a potential candidate to speed up these tasks, but several limitations still bar them from being used effectively. One of the main limitations, and the focus of this work, is that using the device's experimentally accessible temperature as a reference for sampling purposes leads to very poor correlation with the Boltzmann distribution it is programmed to sample from. Based on quantum dynamical arguments, one can expect that if the device indeed happens to be sampling from a Boltzmann-like distribution, it will correspond to one with an instance-dependent effective temperature. Unless this unknown temperature can be unveiled, it might not be possible to effectively use a quantum annealer for Boltzmann sampling processes. In this work, we propose a strategy to overcome this challenge with a simple effective-temperature estimation algorithm. We provide a systematic study assessing the impact of the effective temperatures in the quantum-assisted training of Boltzmann machines, which can serve as a building block for deep learning architectures. This work was supported by NASA Ames Research Center.
Design and analysis of three-arm trials with negative binomially distributed endpoints.
Mütze, Tobias; Munk, Axel; Friede, Tim
2016-02-20
A three-arm clinical trial design with an experimental treatment, an active control, and a placebo control, commonly referred to as the gold standard design, enables testing of non-inferiority or superiority of the experimental treatment compared with the active control. In this paper, we propose methods for designing and analyzing three-arm trials with negative binomially distributed endpoints. In particular, we develop a Wald-type test with a restricted maximum-likelihood variance estimator for testing non-inferiority or superiority. For this test, sample size and power formulas as well as optimal sample size allocations will be derived. The performance of the proposed test will be assessed in an extensive simulation study with regard to type I error rate, power, sample size, and sample size allocation. For the purpose of comparison, Wald-type statistics with a sample variance estimator and an unrestricted maximum-likelihood estimator are included in the simulation study. We found that the proposed Wald-type test with a restricted variance estimator performed well across the considered scenarios and is therefore recommended for application in clinical trials. The methods proposed are motivated and illustrated by a recent clinical trial in multiple sclerosis. The R package ThreeArmedTrials, which implements the methods discussed in this paper, is available on CRAN. Copyright © 2015 John Wiley & Sons, Ltd.
Hosterman, John W.; Flanagan, F.J.; Bragg, Anne; Doughten, M.W.; Filby, R.H.; Grimm, Catherine; Mee, J.S.; Potts, P.J.; Rogers, N.W.
1987-01-01
The concentrations of 3 oxides and 29 elements in 7 National Bureau of Standards (NBS) and 3 Instituto de Pesquisas Techno16gicas (IPT) reference clay samples were etermined by instrumental neutron activation analysis. The analytical work was designed to test the homogeneity of constituents in three new NBS reference clays, NBS-97b, NBS-98b, and NBS-679. The analyses of variance of 276 sets of data for these three standards show that the constituents are distributed homogeneously among bottles of samples for 94 percent of the sets of data. Three of the reference samples (NBS-97, NBS-97a, and NBS-97b) are flint clays; four of the samples (NBS-98, NBS-98a, NBS-98b, and IPT-32) are plastic clays, and three of the samples (NBS-679, IPT-28, and IPT-42) are miscellaneous clays (both sedimentary and residual). Seven clays are predominantly kaolinite; the other three clays contain illite and kaolinite in the approximate ratio 3:2. Seven clays contain quartz as the major nonclay mineral. The mineralogy of the flint and plastic clays from Missouri (NBS-97a and NBS-98a) differs markedly from that of the flint and plastic clays from Pennsylvania (NBS-97, NBS-97b, NBS-98, and NBS-98b). The flint clay NBS-97 has higher average chromium, hafnium, lithium, and zirconium contents than its replacement, reference sample NBS-97b. The differences between the plastic clay NBS-98 and its replacement, NBS-98b, are not as pronounced. The trace element contents of the flint and plastic clays from Missouri, NBS-97a and NBS-98a, differ significantly from those of the clays from Pennsylvania, especially the average rare earth element (REE) contents. The trace element contents of clay sample IPT-32 differ from those of the other plastic clays. IPT-28 and IPT-42 have some average trace element contents that differ not only between these two samples but also from all the other clays. IPT-28 has the highest summation of the average REE contents of the 10 samples. The uranium content of NBS-98a, 46 parts per million, is very much higher than that of the other clays. Plots of average REE contents of the flint and plastic clays, normalized to chondritic abundances, show that the clays from Missouri differ from the same types of clay from Pennsylvania. The plot of REE contents for the miscellaneous clays shows that the normalized means for the elements lanthanum through samarium for IPT-28 are much greater than those for the other miscellaneous clays. The means for the elements europium through lutetium are similar for all three miscellaneous clays.
NASA Astrophysics Data System (ADS)
Harting, Ronald; Bosch, Aleid; Gunnink, Jan
2014-05-01
Society has an increasing demand from the subsurface, which in the Dutch shallow subsurface (upper 30 to 40 meters) mainly focuses on natural aggregate resources, groundwater, infrastructure and dike safety. This stimulates the demand for knowledge about the composition and heterogeneity of the subsurface and its physical and chemical properties, including the uncertainties involved. Physical and chemical properties of sediments in the subsurface have been under investigation for decades; however, the usefulness of this data for applied research and the understanding of these properties is limited. This is due to several factors: studies consist mainly of separately collected datasets, targeted at a limited amount of parameters, focused on a small number of geological units, distributed unevenly with depth and usually collected from clustered drillings with limited spatial extent or are analysed with different techniques and methods, often on disturbed samples. These factors result in a heterogeneous and biased dataset not suitable to function as a reference dataset or to statistically determine regional characteristics of geological units. To overcome these shortcomings, the Geological Survey of the Netherlands is establishing a nation-wide reference dataset for physical and chemical properties. In 2006, a drilling campaign was started using cone penetration tests, cored drillings and geophysical well logs, choosing the sites for a good geographical distribution. The lithological properties of the undisturbed cores are visually described and interpreted for lithostratigraphy and inferred sedimentary environment based on lithofacies. The location of the samples in the cores are chosen based on this description and interpretation, resulting in an evenly distributed dataset of in situ samples with respect to geological units as well as an adequate number of samples suitable for statistical analysis. Analyses are uniformly performed for grain size distribution, permeability (both high and low permeable lithologies) and geochemical methods (X-Ray Fluorescence, Thermo-Gravimetric Analysis, Total Carbon, Total Sulphur and Total Organic Carbon). These analyses result in a large number of lithological, hydrological and geochemical parameters, i.e. clay content, sand median, vertical and horizontal permeability and CaCO3-content. We present the results from the analysis of lithological properties for the Northern Netherlands. Besides geology, these properties can be applied directly in studies concerning (amongst others) groundwater, natural aggregates and dike safety. We demonstrate the use of sedimentary environments based on lithofacies as a useful tool for comparison between lithostratigraphic units and lithofacies. These lithofacies match distinct parts of the marine, fluvial, glacial, eolian or organogenic environment, i.e. tidal channel sand, floodbasin clay and subglacial till. This results in lithological properties illustrating the heterogeneity within a geological unit and between equal depositional environments in different lithostratigraphic units. The acquired data have so far been used in several applied studies, i.e. improving parameterisation of 3D models leading to increased accuracy in groundwater models and dike safety studies concerning dike failure due to undermining. Recently, grain size distributions measured with different methods were recalibrated into a homogeneous dataset using this reference set, which greatly enlarged the dataset to be incorporated in the parameterisation of a 3D voxel model.
Wang, Bei; Wang, Xingyu; Ikeda, Akio; Nagamine, Takashi; Shibasaki, Hiroshi; Nakamura, Masatoshi
2014-01-01
EEG (Electroencephalograph) interpretation is important for the diagnosis of neurological disorders. The proper adjustment of the montage can highlight the EEG rhythm of interest and avoid false interpretation. The aim of this study was to develop an automatic reference selection method to identify a suitable reference. The results may contribute to the accurate inspection of the distribution of EEG rhythms for quantitative EEG interpretation. The method includes two pre-judgements and one iterative detection module. The diffuse case is initially identified by pre-judgement 1 when intermittent rhythmic waveforms occur over large areas along the scalp. The earlobe reference or averaged reference is adopted for the diffuse case due to the effect of the earlobe reference depending on pre-judgement 2. An iterative detection algorithm is developed for the localised case when the signal is distributed in a small area of the brain. The suitable averaged reference is finally determined based on the detected focal and distributed electrodes. The presented technique was applied to the pathological EEG recordings of nine patients. One example of the diffuse case is introduced by illustrating the results of the pre-judgements. The diffusely intermittent rhythmic slow wave is identified. The effect of active earlobe reference is analysed. Two examples of the localised case are presented, indicating the results of the iterative detection module. The focal and distributed electrodes are detected automatically during the repeating algorithm. The identification of diffuse and localised activity was satisfactory compared with the visual inspection. The EEG rhythm of interest can be highlighted using a suitable selected reference. The implementation of an automatic reference selection method is helpful to detect the distribution of an EEG rhythm, which can improve the accuracy of EEG interpretation during both visual inspection and automatic interpretation. Copyright © 2013 IPEM. Published by Elsevier Ltd. All rights reserved.
Schuitemaker, Alie; van Berckel, Bart N M; Kropholler, Marc A; Veltman, Dick J; Scheltens, Philip; Jonker, Cees; Lammertsma, Adriaan A; Boellaard, Ronald
2007-05-01
(R)-[11C]PK11195 has been used for quantifying cerebral microglial activation in vivo. In previous studies, both plasma input and reference tissue methods have been used, usually in combination with a region of interest (ROI) approach. Definition of ROIs, however, can be labourious and prone to interobserver variation. In addition, results are only obtained for predefined areas and (unexpected) signals in undefined areas may be missed. On the other hand, standard pharmacokinetic models are too sensitive to noise to calculate (R)-[11C]PK11195 binding on a voxel-by-voxel basis. Linearised versions of both plasma input and reference tissue models have been described, and these are more suitable for parametric imaging. The purpose of this study was to compare the performance of these plasma input and reference tissue parametric methods on the outcome of statistical parametric mapping (SPM) analysis of (R)-[11C]PK11195 binding. Dynamic (R)-[11C]PK11195 PET scans with arterial blood sampling were performed in 7 younger and 11 elderly healthy subjects. Parametric images of volume of distribution (Vd) and binding potential (BP) were generated using linearised versions of plasma input (Logan) and reference tissue (Reference Parametric Mapping) models. Images were compared at the group level using SPM with a two-sample t-test per voxel, both with and without proportional scaling. Parametric BP images without scaling provided the most sensitive framework for determining differences in (R)-[11C]PK11195 binding between younger and elderly subjects. Vd images could only demonstrate differences in (R)-[11C]PK11195 binding when analysed with proportional scaling due to intersubject variation in K1/k2 (blood-brain barrier transport and non-specific binding).
Rice, Stephen B; Chan, Christopher; Brown, Scott C; Eschbach, Peter; Han, Li; Ensor, David S; Stefaniak, Aleksandr B; Bonevich, John; Vladár, András E; Hight Walker, Angela R; Zheng, Jiwen; Starnes, Catherine; Stromberg, Arnold; Ye, Jia; Grulke, Eric A
2015-01-01
This paper reports an interlaboratory comparison that evaluated a protocol for measuring and analysing the particle size distribution of discrete, metallic, spheroidal nanoparticles using transmission electron microscopy (TEM). The study was focused on automated image capture and automated particle analysis. NIST RM8012 gold nanoparticles (30 nm nominal diameter) were measured for area-equivalent diameter distributions by eight laboratories. Statistical analysis was used to (1) assess the data quality without using size distribution reference models, (2) determine reference model parameters for different size distribution reference models and non-linear regression fitting methods and (3) assess the measurement uncertainty of a size distribution parameter by using its coefficient of variation. The interlaboratory area-equivalent diameter mean, 27.6 nm ± 2.4 nm (computed based on a normal distribution), was quite similar to the area-equivalent diameter, 27.6 nm, assigned to NIST RM8012. The lognormal reference model was the preferred choice for these particle size distributions as, for all laboratories, its parameters had lower relative standard errors (RSEs) than the other size distribution reference models tested (normal, Weibull and Rosin–Rammler–Bennett). The RSEs for the fitted standard deviations were two orders of magnitude higher than those for the fitted means, suggesting that most of the parameter estimate errors were associated with estimating the breadth of the distributions. The coefficients of variation for the interlaboratory statistics also confirmed the lognormal reference model as the preferred choice. From quasi-linear plots, the typical range for good fits between the model and cumulative number-based distributions was 1.9 fitted standard deviations less than the mean to 2.3 fitted standard deviations above the mean. Automated image capture, automated particle analysis and statistical evaluation of the data and fitting coefficients provide a framework for assessing nanoparticle size distributions using TEM for image acquisition. PMID:26361398
Maloney, T.J.; Ludtke, A.S.; Krizman, T.L.
1994-01-01
The US. Geological Survey operates a quality- assurance program based on the analyses of reference samples for the National Water Quality Laboratory in Arvada, Colorado, and the Quality of Water Service Unit in Ocala, Florida. Reference samples containing selected inorganic, nutrient, and low ionic-strength constituents are prepared and disguised as routine samples. The program goal is to determine precision and bias for as many analytical methods offered by the participating laboratories as possible. The samples typically are submitted at a rate of approximately 5 percent of the annual environmental sample load for each constituent. The samples are distributed to the laboratories throughout the year. Analytical data for these reference samples reflect the quality of environmental sample data produced by the laboratories because the samples are processed in the same manner for all steps from sample login through data release. The results are stored permanently in the National Water Data Storage and Retrieval System. During water year 1991, 86 analytical procedures were evaluated at the National Water Quality Laboratory and 37 analytical procedures were evaluated at the Quality of Water Service Unit. An overall evaluation of the inorganic (major ion and trace metal) constituent data for water year 1991 indicated analytical imprecision in the National Water Quality Laboratory for 5 of 67 analytical procedures: aluminum (whole-water recoverable, atomic emission spectrometric, direct-current plasma); calcium (atomic emission spectrometric, direct); fluoride (ion-exchange chromatographic); iron (whole-water recoverable, atomic absorption spectrometric, direct); and sulfate (ion-exchange chromatographic). The results for 11 of 67 analytical procedures had positive or negative bias during water year 1991. Analytical imprecision was indicated in the determination of two of the five National Water Quality Laboratory nutrient constituents: orthophosphate as phosphorus and phosphorus. A negative or positive bias condition was indicated in three of five nutrient constituents. There was acceptable precision and no indication of bias for the 14 low ionic-strength analytical procedures tested in the National Water Quality Laboratory program and for the 32 inorganic and 5 nutrient analytical procedures tested in the Quality of Water Service Unit during water year 1991.
NASA Astrophysics Data System (ADS)
Belan, Boris D.; Voronetskaya, Natalia G.; Pevneva, Galina S.; Golovko, Anatoly K.; Kozlov, Alexandre S.; Malyshkin, Sergey B.; Simonenkov, Denis V.; Davydov, Denis K.; Tolmachev, Gennadii N.; Arshinov, Mikhail Yu.
2017-04-01
In recent years, we have performed aerosol sampling in the atmospheric surface layer (ASL) over different regions of West Siberia in order to reveal peculiarities of the geographical distribution of particulate organic matter (POM). Investigation of the vertical distribution of POM in the troposphere was undertaken by means of aerosol sampling from Optik TU-134 aircraft laboratory in the atmospheric layer from 2 to 8 km during three YAK-AEROSIB campaigns (2012, 2013, and 2014). Aerosol samples were collected onto Teflon filters (PTFE membranes, GRIMM 1.113). The collected aerosol samples were treated as follows: the organic part was extracted from the filter, using chromatographic acetone in an ultrasonic bath; then, it was concentrated in vacuum up to 50 μL, with the subsequent analysis using a chromatography mass spectrometer Agilent 6890N (50 - 250 °C with a rate of 5 °C/min., isotherm at the initial and final temperature - 3 and 45 min, respectively). Hydrocarbons were identified using mass spectral library databases NIST, Wiley, as well as by comparing retention times of reference compounds in model mixtures (Alkane Standard Solutions C8 - C20 and C21 - C40 by SIGMA -ALDRICH). Total organic matter varied from 244.56 ng/m3 in aerosol samples collected in the ASL to 0.08 ng/m3 in the free troposphere (FT) over the Kara Sea. Significant differences were also found in the geographical distribution of POM due to different volatile organic compounds emitted by vegetation in specific regions. Differences between concentrations of POM sampled in the free troposphere over the continent and ocean can exceed an order of magnitude. Average concentration of organic compounds in the ASL is close to 30 ng/m3 and it decreases exponentially with height down to 14 ng/m3 at the top of the atmospheric boundary layer and 5 ng/m3 in the FT.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Longmire, Patrick A.; Goff, Fraser; Counce, D. A.
2004-01-01
Background or baseline water chemistry data and information are required to distingu ish between contaminated and non-contaminated waters for environmental investigations conducted at Los Alamos National Laboratory (referred to as the Laboratory). The term 'background' refers to natural waters discharged by springs or penetrated by wells that have not been contaminated by LANL or other municipal or industrial activities, and that are representative of groundwater discharging from their respective aquifer material. These investigations are conducted as part of the Environmental Restoration (ER) Project, Groundwater Protection Program (GWPP), Laboratory Surveillance Program, the Hydrogeologic Workplan, and the Site-Wide Environmental Impact Statement (SWEIS).more » This poster provides a comprehensive, validated database of inorganic, organic, stable isotope, and radionuclide analyses of up to 136 groundwater samples collected from 15 baseline springs and wells located in and around Los Alamos National Laboratory, New Mexico. The region considered in this investigation extends from the western edge of the Jemez Mountains eastward to the Rio Grande and from Frijoles Canyon northward to Garcia Canyon. Figure 1 shows the fifteen stations sampled for this investigation. The sampling stations and associated aquifer types are summarized in Table 1.« less
Compounds of emerging concern in the San Antonio River Basin, Texas, 2011–12
Lambert, Rebecca B.; Opsahl, Stephen P.
2016-11-16
The City of San Antonio and the surrounding municipalities in Bexar County, Texas, are among the fastest growing cities in the Nation. Increases in residential and commercial development are changing runoff patterns and likely will increase chemical loads into streams. The U.S. Geological Survey, in cooperation with the San Antonio River Authority, evaluated the concentrations and distributional patterns of selected “compounds of emerging concern” (CECs) by collecting and analyzing water-quality samples from 20 sites in the San Antonio River Basin, Tex., during 2011–12. On the basis of their chemical composition or similar uses, the CECs discussed in this fact sheet are wastewater compounds, pharmaceutical compounds (hereinafter referred to as “pharmaceuticals”), and steroidal hormone and sterol compounds (hereinafter referred to as “steroidal hormones and sterols”). Three synoptic sampling events were completed during 2011–12 to analyze for CECs in the San Antonio River Basin. Samples were analyzed for 54 wastewater compounds, 13 pharmaceuticals, 17 steroidal hormones, and 4 sterols. Overall, the concentrations of all CECs analyzed for during this study were low, generally close to or less than the laboratory reporting level.
Distribution of water quality parameters in Dhemaji district, Assam (India).
Buragohain, Mridul; Bhuyan, Bhabajit; Sarma, H P
2010-07-01
The primary objective of this study is to present a statistically significant water quality database of Dhemaji district, Assam (India) with special reference to pH, fluoride, nitrate, arsenic, iron, sodium and potassium. 25 water samples collected from different locations of five development blocks in Dhemaji district have been studied separately. The implications presented are based on statistical analyses of the raw data. Normal distribution statistics and reliability analysis (correlation and covariance matrix) have been employed to find out the distribution pattern, localisation of data, and other related information. Statistical observations show that all the parameters under investigation exhibit non uniform distribution with a long asymmetric tail either on the right or left side of the median. The width of the third quartile was consistently found to be more than the second quartile for each parameter. Differences among mean, mode and median, significant skewness and kurtosis value indicate that the distribution of various water quality parameters in the study area is widely off normal. Thus, the intrinsic water quality is not encouraging due to unsymmetrical distribution of various water quality parameters in the study area.
The Complex Refractive Index of Volcanic Ash Aerosol Retrieved From Spectral Mass Extinction
NASA Astrophysics Data System (ADS)
Reed, Benjamin E.; Peters, Daniel M.; McPheat, Robert; Grainger, R. G.
2018-01-01
The complex refractive indices of eight volcanic ash samples, chosen to have a representative range of SiO2 contents, were retrieved from simultaneous measurements of their spectral mass extinction coefficient and size distribution. The mass extinction coefficients, at 0.33-19 μm, were measured using two optical systems: a Fourier transform spectrometer in the infrared and two diffraction grating spectrometers covering visible and ultraviolet wavelengths. The particle size distribution was measured using a scanning mobility particle sizer and an optical particle counter; values for the effective radius of ash particles measured in this study varied from 0.574 to 1.16 μm. Verification retrievals on high-purity silica aerosol demonstrated that the Rayleigh continuous distribution of ellipsoids (CDEs) scattering model significantly outperformed Mie theory in retrieving the complex refractive index, when compared to literature values. Assuming the silica particles provided a good analogue of volcanic ash, the CDE scattering model was applied to retrieve the complex refractive index of the eight ash samples. The Lorentz formulation of the complex refractive index was used within the retrievals as a convenient way to ensure consistency with the Kramers-Kronig relation. The short-wavelength limit of the electric susceptibility was constrained by using independently measured reference values of the complex refractive index of the ash samples at a visible wavelength. The retrieved values of the complex refractive indices of the ash samples showed considerable variation, highlighting the importance of using accurate refractive index data in ash cloud radiative transfer models.
Smith, Rachel A; Morrison, Daniel
2006-11-01
People often perceive risks for others and themselves differently. This study examines whether personal beliefs about HIV and experience with those living with HIV influence personal risk assessments of contracting HIV in an interview sample of northern Namibians (N=400), but not others' assessments as explained by singular-distribution theory [Klar, Medding, & Sarel (1996). Nonunique invulnerability: Singular versus distributional probabilities and unrealistic optimism in comparative risk judgments. Organizational Behavior and Human Decision Processes, 67, 229-245]. Findings indicate that personal risk perceptions decrease with more HIV stigmatizing beliefs and increase with greater experience, but that those characteristics had no impact on assessments for others' risk. The study also examines whether the size and characteristics of the referent group, peers and the general Namibian population, influence others' risk assessments. Optimistic biases for personal risk versus others' risk appear with the highest discrepancy emerging between personal and general population risk assessments. Further, we found that personal risk perceptions did not mediate the relationship between personal characteristics, beliefs and experiences, and intentions to seek HIV testing.
Marrero, Julieta; Rebagliati, Raúl Jiménez; Gómez, Darío; Smichowski, Patricia
2005-12-15
A study was conducted to evaluate the homogeneity of the distribution of metals and metalloids deposited on glass fiber filters collected using a high-volume sampler equipped with a PM-10 sampling head. The airborne particulate matter (APM)-loaded glass fiber filters (with an active surface of about 500cm(2)) were weighed and then each filter was cut in five small discs of 6.5cm of diameter. Each disk was mineralized by acid-assisted microwave (MW) digestion using a mixture of nitric, perchloric and hydrofluoric acids. Analysis was performed by axial view inductively coupled plasma optical emission spectrometry (ICP OES) and the elements considered were: Al, As, Cd, Cr, Cu, Fe, Mn, Ni, Pb, Sb, Ti and V. The validation of the procedure was performed by the analysis of the standard reference material NIST 1648, urban particulate matter. As a way of comparing the possible variability in trace elements distribution in a particular filter, the mean concentration for each element over the five positions (discs) was calculated and each element concentration was normalized to this mean value. Scatter plots of the normalized concentrations were examined for all elements and all sub-samples. We considered that an element was homogeneously distributed if its normalized concentrations in the 45 sub-samples were within +/-15% of the mean value ranging between 0.85 and 1.15. The study demonstrated that the 12 elements tested showed different distribution pattern. Aluminium, Cu and V showed the most homogeneous pattern while Cd and Ni exhibited the largest departures from the mean value in 13 out of the 45 discs analyzed. No preferential deposition was noticed in any sub-sample.
Petersen, Per H; Lund, Flemming; Fraser, Callum G; Sölétormos, György
2016-11-01
Background The distributions of within-subject biological variation are usually described as coefficients of variation, as are analytical performance specifications for bias, imprecision and other characteristics. Estimation of specifications required for reference change values is traditionally done using relationship between the batch-related changes during routine performance, described as Δbias, and the coefficients of variation for analytical imprecision (CV A ): the original theory is based on standard deviations or coefficients of variation calculated as if distributions were Gaussian. Methods The distribution of between-subject biological variation can generally be described as log-Gaussian. Moreover, recent analyses of within-subject biological variation suggest that many measurands have log-Gaussian distributions. In consequence, we generated a model for the estimation of analytical performance specifications for reference change value, with combination of Δbias and CV A based on log-Gaussian distributions of CV I as natural logarithms. The model was tested using plasma prolactin and glucose as examples. Results Analytical performance specifications for reference change value generated using the new model based on log-Gaussian distributions were practically identical with the traditional model based on Gaussian distributions. Conclusion The traditional and simple to apply model used to generate analytical performance specifications for reference change value, based on the use of coefficients of variation and assuming Gaussian distributions for both CV I and CV A , is generally useful.
42 CFR 7.2 - Establishment of a user charge.
Code of Federal Regulations, 2010 CFR
2010-10-01
... DISTRIBUTION OF REFERENCE BIOLOGICAL STANDARDS AND BIOLOGICAL PREPARATIONS § 7.2 Establishment of a user charge... producing and distributing reference biological standards and biological preparations. ...
Hanford atmospheric dispersion data: 1960 through June 1967
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nickola, P.W.; Ramsdell, J.V.; Glantz, C.S.
1983-11-01
This volume presents dispersion and supporting meteorological data from experiments conducted over relatively flat terrain at Hanford, Washington from January 1960 through June 1967. The nature of the experiments, the sampling grids, and the tracer techniques used are described in the narrative portion of the document. Appendices contain the time-integrated concentrations for samplers within the plumes, summaries of the concentration distributions across the plumes, and wind and temperature profile data for each release period. 18 references, 7 figures, 3 tables.
Hypolactasia in the indigenous populations of northern Russia.
Kozlov, A I
1998-01-01
The distribution of hypolactasia (PH) in the indigenous populations of the polar and related territories of the Russian Federation was investigated by an oral lactose tolerance. The frequency of hypolactasia in Kildin Saami population is 48%, Komi-Izhem-63%, Northern Mansi-71%, Northern Khanty-72%, West Siberia Nenets-78%. Generally hypolactasia frequencies in indigenous groups of Arctic and Sub-Arctic territories of Russia are higher than in the "reference" samples of Slav (Russian, 40-49%) and Permian Finn (Komi-Permiak and Udmurtian, 50-59%) groups.
Homogeneity study of a corn flour laboratory reference material candidate for inorganic analysis.
Dos Santos, Ana Maria Pinto; Dos Santos, Liz Oliveira; Brandao, Geovani Cardoso; Leao, Danilo Junqueira; Bernedo, Alfredo Victor Bellido; Lopes, Ricardo Tadeu; Lemos, Valfredo Azevedo
2015-07-01
In this work, a homogeneity study of a corn flour reference material candidate for inorganic analysis is presented. Seven kilograms of corn flour were used to prepare the material, which was distributed among 100 bottles. The elements Ca, K, Mg, P, Zn, Cu, Fe, Mn and Mo were quantified by inductively coupled plasma optical emission spectrometry (ICP OES) after acid digestion procedure. The method accuracy was confirmed by analyzing the rice flour certified reference material, NIST 1568a. All results were evaluated by analysis of variance (ANOVA) and principal component analysis (PCA). In the study, a sample mass of 400mg was established as the minimum mass required for analysis, according to the PCA. The between-bottle test was performed by analyzing 9 bottles of the material. Subsamples of a single bottle were analyzed for the within-bottle test. No significant differences were observed for the results obtained through the application of both statistical methods. This fact demonstrates that the material is homogeneous for use as a laboratory reference material. Copyright © 2015 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Khanmohammadi, Neda; Rezaie, Hossein; Montaseri, Majid; Behmanesh, Javad
2017-10-01
The reference evapotranspiration (ET0) plays an important role in water management plans in arid or semi-arid countries such as Iran. For this reason, the regional analysis of this parameter is important. But, ET0 process is affected by several meteorological parameters such as wind speed, solar radiation, temperature and relative humidity. Therefore, the effect of distribution type of effective meteorological variables on ET0 distribution was analyzed. For this purpose, the regional probability distribution of the annual ET0 and its effective parameters were selected. Used data in this research was recorded data at 30 synoptic stations of Iran during 1960-2014. Using the probability plot correlation coefficient (PPCC) test and the L-moment method, five common distributions were compared and the best distribution was selected. The results of PPCC test and L-moment diagram indicated that the Pearson type III distribution was the best probability distribution for fitting annual ET0 and its four effective parameters. The results of RMSE showed that the ability of the PPCC test and L-moment method for regional analysis of reference evapotranspiration and its effective parameters was similar. The results also showed that the distribution type of the parameters which affected ET0 values can affect the distribution of reference evapotranspiration.
[Information flow between medical and social sciences].
Schubert, András; Somogyi, Anikó
2014-12-28
In order to reveal impacts of natural and social sciences on each other, the authors examined connections between fields of medical and social sciences using a search for references and citations of scientific publication. 1. The largest affinity between the medical and social sciences was found between neurosciences and psychology, but there was a significant affinity between clinical sciences and general social sciences, as well. 2. The example of General & Internal Medicine papers in the topics of "diabetes" suggests that in the period 2001-2010 the share of references to social sciences was significantly increased. In the meantime, social science papers in the same topics contained references to Clinical Medicine papers in a constantly high percentage. 3. In the sample under study, the age distribution of social science papers in the references did not differ significantly from that of the other sources. 4. Share of references to social science papers was found to be extremely high among Hungarian General & Internal Medicine papers in the topics of "diabetes". This finding still requires clarification, nevertheless, since e.g. it was not supported by an institutional comparison including the largest Hungarian medical research university. 5. The intensity of the reference/citation mediated information flows between the Hungarian Medical Journal, Orvosi Hetilap and social sciences appears to be in accordance with the current international trends.
ElMasry, Gamal; Nakauchi, Shigeki
2016-03-01
A simulation method for approximating spectral signatures of minced meat samples was developed depending on concentrations and optical properties of the major chemical constituents. Minced beef samples of different compositions scanned on a near-infrared spectroscopy and on a hyperspectral imaging system were examined. Chemical composition determined heuristically and optical properties collected from authenticated references were simulated to approximate samples' spectral signatures. In short-wave infrared range, the resulting spectrum equals the sum of the absorption of three individual absorbers, that is, water, protein, and fat. By assuming homogeneous distributions of the main chromophores in the mince samples, the obtained absorption spectra are found to be a linear combination of the absorption spectra of the major chromophores present in the sample. Results revealed that developed models were good enough to derive spectral signatures of minced meat samples with a reasonable level of robustness of a high agreement index value more than 0.90 and ratio of performance to deviation more than 1.4.
NASA Astrophysics Data System (ADS)
Chen, Ming; Guo, Jiming; Li, Zhicai; Zhang, Peng; Wu, Junli; Song, Weiwei
2017-04-01
BDS precision orbit determination is a key content of the BDS application, but the inadequate ground stations and the poor distribution of the network are the main reasons for the low accuracy of BDS precise orbit determination. In this paper, the BDS precise orbit determination results are obtained by using the IGS MGEX stations and the Chinese national reference stations,the accuracy of orbit determination of GEO, IGSO and MEO is 10.3cm, 2.8cm and 3.2cm, and the radial accuracy is 1.6cm,1.9cm and 1.5cm.The influence of ground reference stations distribution on BDS precise orbit determination is studied. The results show that the Chinese national reference stations contribute significantly to the BDS orbit determination, the overlap precision of GEO/IGSO/MEO satellites were improved by 15.5%, 57.5% and 5.3% respectively after adding the Chinese stations.Finally, the results of ODOP(orbit distribution of precision) and SLR are verified. Key words: BDS precise orbit determination; accuracy assessment;Chinese national reference stations;reference stations distribution;orbit distribution of precision
NASA Astrophysics Data System (ADS)
Scholtz, J.; Alexander, D. M.; Harrison, C. M.; Rosario, D. J.; McAlpine, S.; Mullaney, J. R.; Stanley, F.; Simpson, J.; Theuns, T.; Bower, R. G.; Hickox, R. C.; Santini, P.; Swinbank, A. M.
2018-03-01
We present sensitive 870 μm continuum measurements from our ALMA programmes of 114 X-ray selected active galactic nuclei (AGN) in the Chandra Deep Field-South and Cosmic Evolution Survey fields. We use these observations in combination with data from Spitzer and Herschel to construct a sample of 86 X-ray selected AGN, 63 with ALMA constraints at z = 1.5-3.2 with stellar mass >2 × 1010 M⊙. We constructed broad-band spectral energy distributions in the infrared band (8-1000 μm) and constrain star-formation rates (SFRs) uncontaminated by the AGN. Using a hierarchical Bayesian method that takes into account the information from upper limits, we fit SFR and specific SFR (sSFR) distributions. We explore these distributions as a function of both X-ray luminosity and stellar mass. We compare our measurements to two versions of the Evolution and Assembly of GaLaxies and their Environments (EAGLE) hydrodynamical simulations: the reference model with AGN feedback and the model without AGN. We find good agreement between the observations and that predicted by the EAGLE reference model for the modes and widths of the sSFR distributions as a function of both X-ray luminosity and stellar mass; however, we found that the EAGLE model without AGN feedback predicts a significantly narrower width when compared to the data. Overall, from the combination of the observations with the model predictions, we conclude that (1) even with AGN feedback, we expect no strong relationship between the sSFR distribution parameters and instantaneous AGN luminosity and (2) a signature of AGN feedback is a broad distribution of sSFRs for all galaxies (not just those hosting an AGN) with stellar masses above ≈1010 M⊙.
NASA Astrophysics Data System (ADS)
Tinas, Hande; Ozbek, Nil; Akman, Suleyman
2018-02-01
In this study, lead concentrations in various flour samples were determined by high-resolution continuum source graphite furnace atomic absorption spectrometry with solid sampling. Since samples were analyzed directly, the risks and disadvantages of sample digestion were eliminated. Solid flour samples were dried, weighed on the platforms, Pd was added as a modifier and introduced directly into a graphite tube using a manual solid sampler. Platforms and tubes were coated with Zr. The optimized pyrolysis and atomization temperatures were 800 °C and 2200 °C, respectively. The sensitivities of lead in various flour certified reference materials (CRMs) and aqueous standards were not significantly different. Therefore, aqueous standards were safely used for calibration. The absolute limit of detection and characteristic mass were 7.2 pg and 9.0 pg of lead, respectively. The lead concentrations in different types of flour samples were found in the range of 25-52 μg kg- 1. Finally, homogeneity factors representing the heterogeneity of analyte distribution for lead in flour samples were determined.
NASA Technical Reports Server (NTRS)
Veldhuis, Hugo; Hall, Forrest G. (Editor); Knapp, David E. (Editor)
2000-01-01
This data set contains the major soil properties of soil samples collected in 1994 at the tower flux sites in the Northern Study Area (NSA). The soil samples were collected by Hugo Veldhuis and his staff from the University of Manitoba. The mineral soil samples were largely analyzed by Barry Goetz, under the supervision of Dr. Harold Rostad at the University of Saskatchewan. The organic soil samples were largely analyzed by Peter Haluschak, under the supervision of Hugo Veldhuis at the Centre for Land and Biological Resources Research in Winnipeg, Manitoba. During the course of field investigation and mapping, selected surface and subsurface soil samples were collected for laboratory analysis. These samples were used as benchmark references for specific soil attributes in general soil characterization. Detailed soil sampling, description, and laboratory analysis were performed on selected modal soils to provide examples of common soil physical and chemical characteristics in the study area. The soil properties that were determined include soil horizon; dry soil color; pH; bulk density; total, organic, and inorganic carbon; electric conductivity; cation exchange capacity; exchangeable sodium, potassium, calcium, magnesium, and hydrogen; water content at 0.01, 0.033, and 1.5 MPascals; nitrogen; phosphorus: particle size distribution; texture; pH of the mineral soil and of the organic soil; extractable acid; and sulfur. These data are stored in ASCII text files. The data files are available on a CD-ROM (see document number 20010000884), or from the Oak Ridge National Laboratory (ORNL) Distributed Active Archive Center (DAAC).
Assessing the Application of a Geographic Presence-Only Model for Land Suitability Mapping
Heumann, Benjamin W.; Walsh, Stephen J.; McDaniel, Phillip M.
2011-01-01
Recent advances in ecological modeling have focused on novel methods for characterizing the environment that use presence-only data and machine-learning algorithms to predict the likelihood of species occurrence. These novel methods may have great potential for land suitability applications in the developing world where detailed land cover information is often unavailable or incomplete. This paper assesses the adaptation and application of the presence-only geographic species distribution model, MaxEnt, for agricultural crop suitability mapping in a rural Thailand where lowland paddy rice and upland field crops predominant. To assess this modeling approach, three independent crop presence datasets were used including a social-demographic survey of farm households, a remote sensing classification of land use/land cover, and ground control points, used for geodetic and thematic reference that vary in their geographic distribution and sample size. Disparate environmental data were integrated to characterize environmental settings across Nang Rong District, a region of approximately 1,300 sq. km in size. Results indicate that the MaxEnt model is capable of modeling crop suitability for upland and lowland crops, including rice varieties, although model results varied between datasets due to the high sensitivity of the model to the distribution of observed crop locations in geographic and environmental space. Accuracy assessments indicate that model outcomes were influenced by the sample size and the distribution of sample points in geographic and environmental space. The need for further research into accuracy assessments of presence-only models lacking true absence data is discussed. We conclude that the Maxent model can provide good estimates of crop suitability, but many areas need to be carefully scrutinized including geographic distribution of input data and assessment methods to ensure realistic modeling results. PMID:21860606
Optical distribution of local oscillators in future telecommunication satellite payloads
NASA Astrophysics Data System (ADS)
Benazet, Benoît; Sotom, Michel; Maignan, Michel; Berthon, Jacques
2017-11-01
The distribution of high spectral purity reference signals over optical fibre in future telecommunication satellite payloads is presented. Several types of applications are considered, including the distribution of a reference frequency at 10 MHz (Ultra-Stable Reference Oscillator) as well as the distribution of a radiofrequency oscillator around 800 MHz (Master Local Oscillator). The results of both experimental and theoretical studies are reported. In order to meet phase noise requirements for the USRO distribution, the use of an optimised receiver circuit based on an optically synchronised oscillator is investigated. Finally, the optical distribution of microwave local oscillators at frequencies exceeding 20 GHz is described. Such a scheme paves the way to more advanced sub-systems involving optical frequency-mixing and optical transmission of microwave signals, with applications to multiple-beam active antennas.
Whiting, S D; Guinea, M L; Fomiatti, K; Flint, M; Limpus, C J
2014-06-14
In recent years, the use of blood chemistry as a diagnostic tool for sea turtles has been demonstrated, but much of its effectiveness relies on reference intervals. The first comprehensive blood chemistry values for healthy wild hawksbill (Eretmochelys imbricata) sea turtles are presented. Nineteen blood chemistry analytes and packed cell volume were analysed for 40 clinically healthy juvenile hawksbill sea turtles captured from a rocky reef habitat in northern Australia. We used four statistical approaches to calculate reference intervals and to investigate their use with non-normal distributions and small sample sizes, and to compare upper and lower limits between methods. Eleven analytes were correlated with curved carapace length indicating that body size should be considered when designing future studies and interpreting analyte values. British Veterinary Association.
Keyword extraction by entropy difference between the intrinsic and extrinsic mode
NASA Astrophysics Data System (ADS)
Yang, Zhen; Lei, Jianjun; Fan, Kefeng; Lai, Yingxu
2013-10-01
This paper proposes a new metric to evaluate and rank the relevance of words in a text. The method uses the Shannon’s entropy difference between the intrinsic and extrinsic mode, which refers to the fact that relevant words significantly reflect the author’s writing intention, i.e., their occurrences are modulated by the author’s purpose, while the irrelevant words are distributed randomly in the text. By using The Origin of Species by Charles Darwin as a representative text sample, the performance of our detector is demonstrated and compared to previous proposals. Since a reference text “corpus” is all of an author’s writings, books, papers, etc. his collected works is not needed. Our approach is especially suitable for single documents of which there is no a priori information available.
Baird, Zachariah Steven; Oja, Vahur; Järvik, Oliver
2015-05-01
This article describes the use of Fourier transform infrared (FT-IR) spectroscopy to quantitatively measure the hydroxyl concentrations among narrow boiling shale oil cuts. Shale oil samples were from an industrial solid heat carrier retort. Reference values were measured by titration and were used to create a partial least squares regression model from FT-IR data. The model had a root mean squared error (RMSE) of 0.44 wt% OH. This method was then used to study the distribution of hydroxyl groups among more than 100 shale oil cuts, which showed that hydroxyl content increased with the average boiling point of the cut up to about 350 °C and then leveled off and decreased.
Theory, the Final Frontier? A Corpus-Based Analysis of the Role of Theory in Psychological Articles.
Beller, Sieghard; Bender, Andrea
2017-01-01
Contemporary psychology regards itself as an empirical science, at least in most of its subfields. Theory building and development are often considered critical to the sciences, but the extent to which psychology can be cast in this way is under debate. According to those advocating a strong role of theory, studies should be designed to test hypotheses derived from theories (theory-driven) and ideally should yield findings that stimulate hypothesis formation and theory building (theory-generating). The alternative position values empirical findings over theories as the lasting legacy of science. To investigate which role theory actually plays in current research practice, we analyse references to theory in the complete set of 2,046 articles accepted for publication in Frontiers of Psychology in 2015. This sample of articles, while not representative in the strictest sense, covers a broad range of sub-disciplines, both basic and applied, and a broad range of article types, including research articles, reviews, hypothesis & theory, and commentaries. For the titles, keyword lists, and abstracts in this sample, we conducted a text search for terms related to empiricism and theory, assessed the frequency and scope of usage for six theory-related terms, and analyzed their distribution over different article types and subsections of the journal. The results indicate substantially lower frequencies of theoretical than empirical terms, with references to a specific (named) theory in less than 10% of the sample and references to any of even the most frequently mentioned theories in less than 0.5% of the sample. In conclusion, we discuss possible limitations of our study and the prospect of theoretical advancement.
Theory, the Final Frontier? A Corpus-Based Analysis of the Role of Theory in Psychological Articles
Beller, Sieghard; Bender, Andrea
2017-01-01
Contemporary psychology regards itself as an empirical science, at least in most of its subfields. Theory building and development are often considered critical to the sciences, but the extent to which psychology can be cast in this way is under debate. According to those advocating a strong role of theory, studies should be designed to test hypotheses derived from theories (theory-driven) and ideally should yield findings that stimulate hypothesis formation and theory building (theory-generating). The alternative position values empirical findings over theories as the lasting legacy of science. To investigate which role theory actually plays in current research practice, we analyse references to theory in the complete set of 2,046 articles accepted for publication in Frontiers of Psychology in 2015. This sample of articles, while not representative in the strictest sense, covers a broad range of sub-disciplines, both basic and applied, and a broad range of article types, including research articles, reviews, hypothesis & theory, and commentaries. For the titles, keyword lists, and abstracts in this sample, we conducted a text search for terms related to empiricism and theory, assessed the frequency and scope of usage for six theory-related terms, and analyzed their distribution over different article types and subsections of the journal. The results indicate substantially lower frequencies of theoretical than empirical terms, with references to a specific (named) theory in less than 10% of the sample and references to any of even the most frequently mentioned theories in less than 0.5% of the sample. In conclusion, we discuss possible limitations of our study and the prospect of theoretical advancement. PMID:28642728
Characterization of 137 Genomic DNA Reference Materials for 28 Pharmacogenetic Genes
Pratt, Victoria M.; Everts, Robin E.; Aggarwal, Praful; Beyer, Brittany N.; Broeckel, Ulrich; Epstein-Baak, Ruth; Hujsak, Paul; Kornreich, Ruth; Liao, Jun; Lorier, Rachel; Scott, Stuart A.; Smith, Chingying Huang; Toji, Lorraine H.; Turner, Amy; Kalman, Lisa V.
2017-01-01
Pharmacogenetic testing is increasingly available from clinical laboratories. However, only a limited number of quality control and other reference materials are currently available to support clinical testing. To address this need, the Centers for Disease Control and Prevention–based Genetic Testing Reference Material Coordination Program, in collaboration with members of the pharmacogenetic testing community and the Coriell Cell Repositories, has characterized 137 genomic DNA samples for 28 genes commonly genotyped by pharmacogenetic testing assays (CYP1A1, CYP1A2, CYP2A6, CYP2B6, CYP2C8, CYP2C9, CYP2C19, CYP2D6, CYP2E1, CYP3A4, CYP3A5, CYP4F2, DPYD, GSTM1, GSTP1, GSTT1, NAT1, NAT2, SLC15A2, SLC22A2, SLCO1B1, SLCO2B1, TPMT, UGT1A1, UGT2B7, UGT2B15, UGT2B17, and VKORC1). One hundred thirty-seven Coriell cell lines were selected based on ethnic diversity and partial genotype characterization from earlier testing. DNA samples were coded and distributed to volunteer testing laboratories for targeted genotyping using a number of commercially available and laboratory developed tests. Through consensus verification, we confirmed the presence of at least 108 variant pharmacogenetic alleles. These samples are also being characterized by other pharmacogenetic assays, including next-generation sequencing, which will be reported separately. Genotyping results were consistent among laboratories, with most differences in allele assignments attributed to assay design and variability in reported allele nomenclature, particularly for CYP2D6, UGT1A1, and VKORC1. These publicly available samples will help ensure the accuracy of pharmacogenetic testing. PMID:26621101
Burade, Vinod; Bhowmick, Subhas; Maiti, Kuntal; Zalawadia, Rishit; Jain, Deepak; Rajamannar, Thennati
2017-05-01
The liposomal formulation of doxorubicin [doxorubicin (DXR) hydrochloride (HCl) liposome injection, Caelyx ® ] alters the tissue distribution of DXR as compared with nonliposomal DXR, resulting in an improved benefit-risk profile. We conducted studies in murine models to compare the plasma and tissue distribution of a proposed generic DXR HCl liposome injection developed by Sun Pharmaceuticals Industries Limited (SPIL DXR HCl liposome injection) with Caelyx ® . The plasma and tissue distributions of the SPIL and reference DXR HCl liposome injections were compared in syngeneic fibrosarcoma-bearing BALB/c mice and Sprague-Dawley rats. Different batches and different lots of the same batch of the reference product were also compared with each other. The SPIL and reference DXR HCl liposome injections exhibited generally comparable plasma and tissue distribution profiles in both models. While minor differences were observed between the two products in some tissues, different batches and lots of the reference product also showed some differences in the distribution of various analytes in some tissues. The ratios of estimated free to encapsulated DXR for plasma and tissue were generally comparable between the SPIL and reference DXR HCl liposome injections in both models, indicating similar extents of absorption into the tissues and similar rates of drug release from liposomes. The plasma and tissue distribution profiles of the SPIL and reference DXR HCl liposome injections were shown to be generally comparable. Inconsistencies between the products observed in some tissues were thought to be due to biological variation.
Intra prediction using face continuity in 360-degree video coding
NASA Astrophysics Data System (ADS)
Hanhart, Philippe; He, Yuwen; Ye, Yan
2017-09-01
This paper presents a new reference sample derivation method for intra prediction in 360-degree video coding. Unlike the conventional reference sample derivation method for 2D video coding, which uses the samples located directly above and on the left of the current block, the proposed method considers the spherical nature of 360-degree video when deriving reference samples located outside the current face to which the block belongs, and derives reference samples that are geometric neighbors on the sphere. The proposed reference sample derivation method was implemented in the Joint Exploration Model 3.0 (JEM-3.0) for the cubemap projection format. Simulation results for the all intra configuration show that, when compared with the conventional reference sample derivation method, the proposed method gives, on average, luma BD-rate reduction of 0.3% in terms of the weighted spherical PSNR (WS-PSNR) and spherical PSNR (SPSNR) metrics.
Grimm, Annegret; Gruber, Bernd; Henle, Klaus
2014-01-01
Reliable estimates of population size are fundamental in many ecological studies and biodiversity conservation. Selecting appropriate methods to estimate abundance is often very difficult, especially if data are scarce. Most studies concerning the reliability of different estimators used simulation data based on assumptions about capture variability that do not necessarily reflect conditions in natural populations. Here, we used data from an intensively studied closed population of the arboreal gecko Gehyra variegata to construct reference population sizes for assessing twelve different population size estimators in terms of bias, precision, accuracy, and their 95%-confidence intervals. Two of the reference populations reflect natural biological entities, whereas the other reference populations reflect artificial subsets of the population. Since individual heterogeneity was assumed, we tested modifications of the Lincoln-Petersen estimator, a set of models in programs MARK and CARE-2, and a truncated geometric distribution. Ranking of methods was similar across criteria. Models accounting for individual heterogeneity performed best in all assessment criteria. For populations from heterogeneous habitats without obvious covariates explaining individual heterogeneity, we recommend using the moment estimator or the interpolated jackknife estimator (both implemented in CAPTURE/MARK). If data for capture frequencies are substantial, we recommend the sample coverage or the estimating equation (both models implemented in CARE-2). Depending on the distribution of catchabilities, our proposed multiple Lincoln-Petersen and a truncated geometric distribution obtained comparably good results. The former usually resulted in a minimum population size and the latter can be recommended when there is a long tail of low capture probabilities. Models with covariates and mixture models performed poorly. Our approach identified suitable methods and extended options to evaluate the performance of mark-recapture population size estimators under field conditions, which is essential for selecting an appropriate method and obtaining reliable results in ecology and conservation biology, and thus for sound management. PMID:24896260
Morio, Florent; Corvec, Stéphane; Caroff, Nathalie; Le Gallou, Florence; Drugeon, Henri; Reynaud, Alain
2008-07-01
We developed a quantitative real-time PCR assay targeting the mip gene of Legionella pneumophila for a prospective study from September 2004 to April 2005. It was compared with a standard culture method (French guideline AFNOR T90-431), analysing 120 water samples collected to monitor the risk related to Legionellae at Nantes hospital and to investigate a case of legionellosis acquired from hospital environment. Samples from six distinct water distribution systems were analysed by DNA extraction, amplification and detection with specific primers and FRET probes. The detection limit was 100 genomic units of L. pneumophila per liter (GU/l), the positivity threshold about 600 GU/l and the quantification limit 800 GU/l. PCR results were divided into three groups: negative (n=63), positive but non-quantifiable (n=22) or positive (n=35). PCR showed higher sensitivity than culture, whereas four culture-positive samples appeared negative by PCR (PCR inhibitor detected for two of them). Although no correlation was observed between both methods and real-time PCR cannot substitute for the reference method, it represents an interesting complement. Its sensitivity, reproducibility and rapidity appear particularly interesting in epidemic contexts in order to identify the source of contamination or to evaluate critical points of contamination in water distribution systems.
the-wizz: clustering redshift estimation for everyone
NASA Astrophysics Data System (ADS)
Morrison, C. B.; Hildebrandt, H.; Schmidt, S. J.; Baldry, I. K.; Bilicki, M.; Choi, A.; Erben, T.; Schneider, P.
2017-05-01
We present the-wizz, an open source and user-friendly software for estimating the redshift distributions of photometric galaxies with unknown redshifts by spatially cross-correlating them against a reference sample with known redshifts. The main benefit of the-wizz is in separating the angular pair finding and correlation estimation from the computation of the output clustering redshifts allowing anyone to create a clustering redshift for their sample without the intervention of an 'expert'. It allows the end user of a given survey to select any subsample of photometric galaxies with unknown redshifts, match this sample's catalogue indices into a value-added data file and produce a clustering redshift estimation for this sample in a fraction of the time it would take to run all the angular correlations needed to produce a clustering redshift. We show results with this software using photometric data from the Kilo-Degree Survey (KiDS) and spectroscopic redshifts from the Galaxy and Mass Assembly survey and the Sloan Digital Sky Survey. The results we present for KiDS are consistent with the redshift distributions used in a recent cosmic shear analysis from the survey. We also present results using a hybrid machine learning-clustering redshift analysis that enables the estimation of clustering redshifts for individual galaxies. the-wizz can be downloaded at http://github.com/morriscb/The-wiZZ/.
S-SIMS and MetA-SIMS study of organic additives in thin polymer coatings
NASA Astrophysics Data System (ADS)
Adriaensen, L.; Vangaever, F.; Lenaerts, J.; Gijbels, R.
2006-07-01
In the present study a methodology for TOF-S-SIMS measurements is developed to gain information on the distribution of molecules on and in polymer coatings (thickness ˜100 μm). Experiments were carried out on model systems consisting of one or more additive-containing polyvinylbutyral coatings. Several organic additives were selected: carbocyanine dyes, basonyl blue and the pharmaceutical risperidone. The additives have been measured as pure compounds on a Si substrate to obtain good reference spectra. After optimisation of the sample preparation method, the coatings were embedded in epoxy resin and stored in an oven (60 °C) for 24 h. Cross-sections were made by means of a microtome. S-SIMS spectra were taken on the prepared cross-sections before and after Au was deposited on the sample surface. Compared to the untreated samples, the Au covered samples give rise to more intense secondary ion signals. Generally, signals of the intact cations were more intense than those of the fragment ions. Apart from mass spectra, images of the additive distribution in the coatings could also be acquired by recording structural ion signals. It was possible to make secondary ion images of the additive molecule ions with a (sub)-micrometer lateral resolution.
An improved AVC strategy applied in distributed wind power system
NASA Astrophysics Data System (ADS)
Zhao, Y. N.; Liu, Q. H.; Song, S. Y.; Mao, W.
2016-08-01
Traditional AVC strategy is mainly used in wind farm and only concerns about grid connection point, which is not suitable for distributed wind power system. Therefore, this paper comes up with an improved AVC strategy applied in distributed wind power system. The strategy takes all nodes of distribution network into consideration and chooses the node having the most serious voltage deviation as control point to calculate the reactive power reference. In addition, distribution principles can be divided into two conditions: when wind generators access to network on single node, the reactive power reference is distributed according to reactive power capacity; when wind generators access to network on multi-node, the reference is distributed according to sensitivity. Simulation results show the correctness and reliability of the strategy. Compared with traditional control strategy, the strategy described in this paper can make full use of generators reactive power output ability according to the distribution network voltage condition and improve the distribution network voltage level effectively.
Sharpless, K E; Gill, L M
2000-01-01
A number of food-matrix reference materials (RMs) are available from the National Institute of Standards and Technology (NIST) and from Agriculture Canada through NIST. Most of these materials were originally value-assigned for their elemental composition (major, minor, and trace elements), but no additional nutritional information was provided. Two of the materials were certified for selected organic constituents. Ten of these materials (Standard Reference Material [SRM] 1,563 Cholesterol and Fat-Soluble Vitamins in Coconut Oil [Natural and Fortified], SRM 1,566b Oyster Tissue, SRM 1,570a Spinach Leaves, SRM 1,974a Organics in Mussel Tissue (Mytilus edulis), RM 8,415 Whole Egg Powder, RM 8,418 Wheat Gluten, RM 8,432 Corn Starch, RM 8,433 Corn Bran, RM 8,435 Whole Milk Powder, and RM 8,436 Durum Wheat Flour) were recently distributed by NIST to 4 laboratories with expertise in food analysis for the measurement of proximates (solids, fat, protein, etc.), calories, and total dietary fiber, as appropriate. SRM 1846 Infant Formula was distributed as a quality control sample for the proximates and for analysis for individual fatty acids. Two of the materials (Whole Egg Powder and Whole Milk Powder) were distributed in an earlier interlaboratory comparison exercise in which they were analyzed for several vitamins. Value assignment of analyte concentrations in these 11 SRMs and RMs, based on analyses by the collaborating laboratories, is described in this paper. These materials are intended primarily for validation of analytical methods for the measurement of nutrients in foods of similar composition (based on AOAC INTERNATIONAL's fat-protein-carbohydrate triangle). They may also be used as "primary control materials" in the value assignment of in-house control materials of similar composition. The addition of proximate information for 10 existing reference materials means that RMs are now available from NIST with assigned values for proximates in 6 of the 9 sectors of the AOAC triangle. Five of these materials have values assigned for total dietary fiber-the first such information provided for materials available from NIST.
NASA Astrophysics Data System (ADS)
Mouton, M.; Botha, A.; Thornton, M.; Mesjasz-Przybyłowicz, J.; Przybyłowicz, W. J.
2015-11-01
Several studies revealed that anthropogenic activities often cause toxic concentrations of some elements, such as mercury, which bio-accumulate through the marine food chain, impacting negatively on the health of animals in the top trophic levels, such as a variety of marine mammals. Moreover, analysis of cetacean skin has been reported to be a reliable, long-term and mostly non-invasive method to monitor bio-accumulation of chemicals in cetacean populations. Several elements, including trace elements, occur naturally in cetacean skin, although nothing is known about their distribution patterns and little about safe base line concentrations. In May 2009, 42 false killer whales (FKWs) beached and died at Kommetjie in the Western Cape of South Africa. Skin samples of these FKWs were collected and analysed to determine elemental distribution patterns. The concentrations and distribution patterns of the major, as well as detectable trace elements were determined in skin samples from ten randomly selected FKW individuals, using micro-PIXE (particle-induced X-ray emission) analysis. Results revealed differences between the distribution patterns of elements in the skin sections. Fe, for example, was found to be concentrated in the dermal papillae, whereas the highest Zn concentrations occurred in the epidermis and particularly in the epidermal papillae. Since these essential elements mediate factors such as host immunity, from skin integrity to humoral immunity, knowledge of their typical distribution patterns can be of great value in studies of bio-accumulation. This is the first report of micro-PIXE being employed to study elemental distribution in cetacean skin and the resulting elemental distribution maps can serve as reference in future environmental pollution studies.
Geostatistical Sampling Methods for Efficient Uncertainty Analysis in Flow and Transport Problems
NASA Astrophysics Data System (ADS)
Liodakis, Stylianos; Kyriakidis, Phaedon; Gaganis, Petros
2015-04-01
In hydrogeological applications involving flow and transport of in heterogeneous porous media the spatial distribution of hydraulic conductivity is often parameterized in terms of a lognormal random field based on a histogram and variogram model inferred from data and/or synthesized from relevant knowledge. Realizations of simulated conductivity fields are then generated using geostatistical simulation involving simple random (SR) sampling and are subsequently used as inputs to physically-based simulators of flow and transport in a Monte Carlo framework for evaluating the uncertainty in the spatial distribution of solute concentration due to the uncertainty in the spatial distribution of hydraulic con- ductivity [1]. Realistic uncertainty analysis, however, calls for a large number of simulated concentration fields; hence, can become expensive in terms of both time and computer re- sources. A more efficient alternative to SR sampling is Latin hypercube (LH) sampling, a special case of stratified random sampling, which yields a more representative distribution of simulated attribute values with fewer realizations [2]. Here, term representative implies realizations spanning efficiently the range of possible conductivity values corresponding to the lognormal random field. In this work we investigate the efficiency of alternative methods to classical LH sampling within the context of simulation of flow and transport in a heterogeneous porous medium. More precisely, we consider the stratified likelihood (SL) sampling method of [3], in which attribute realizations are generated using the polar simulation method by exploring the geometrical properties of the multivariate Gaussian distribution function. In addition, we propose a more efficient version of the above method, here termed minimum energy (ME) sampling, whereby a set of N representative conductivity realizations at M locations is constructed by: (i) generating a representative set of N points distributed on the surface of a M-dimensional, unit radius hyper-sphere, (ii) relocating the N points on a representative set of N hyper-spheres of different radii, and (iii) transforming the coordinates of those points to lie on N different hyper-ellipsoids spanning the multivariate Gaussian distribution. The above method is applied in a dimensionality reduction context by defining flow-controlling points over which representative sampling of hydraulic conductivity is performed, thus also accounting for the sensitivity of the flow and transport model to the input hydraulic conductivity field. The performance of the various stratified sampling methods, LH, SL, and ME, is compared to that of SR sampling in terms of reproduction of ensemble statistics of hydraulic conductivity and solute concentration for different sample sizes N (numbers of realizations). The results indicate that ME sampling constitutes an equally if not more efficient simulation method than LH and SL sampling, as it can reproduce to a similar extent statistics of the conductivity and concentration fields, yet with smaller sampling variability than SR sampling. References [1] Gutjahr A.L. and Bras R.L. Spatial variability in subsurface flow and transport: A review. Reliability Engineering & System Safety, 42, 293-316, (1993). [2] Helton J.C. and Davis F.J. Latin hypercube sampling and the propagation of uncertainty in analyses of complex systems. Reliability Engineering & System Safety, 81, 23-69, (2003). [3] Switzer P. Multiple simulation of spatial fields. In: Heuvelink G, Lemmens M (eds) Proceedings of the 4th International Symposium on Spatial Accuracy Assessment in Natural Resources and Environmental Sciences, Coronet Books Inc., pp 629?635 (2000).
Automatic HTS force measurement instrument
Sanders, Scott T.; Niemann, Ralph C.
1999-01-01
A device for measuring the levitation force of a high temperature superconductor sample with respect to a reference magnet includes a receptacle for holding several high temperature superconductor samples each cooled to superconducting temperature. A rotatable carousel successively locates a selected one of the high temperature superconductor samples in registry with the reference magnet. Mechanism varies the distance between one of the high temperature superconductor samples and the reference magnet, and a sensor measures levitation force of the sample as a function of the distance between the reference magnet and the sample. A method is also disclosed.
NASA Astrophysics Data System (ADS)
Cawley, Kaelin M.; McKnight, Diane M.; Miller, Penney; Cory, Rose; Fimmen, Ryan L.; Guerard, Jennifer; Dieser, Markus; Jaros, Christopher; Chin, Yu-Ping; Foreman, Christine
2013-12-01
Dissolved humic material (HDOM) is ubiquitous to all natural waters and its source material influences its chemical structure, reactivity, and bioavailability. While terrestrially derived HDOM reference materials distributed by the International Humic Substances Society (IHSS) have been readily available to engineering and scientific communities, a microbially derived reference HDOM was not, despite the well-characterized differences in the chemistry and reactivity of HDOM derived from terrestrial versus microbial sources. To address this gap, we collected a microbial reference fulvic acid from Pony Lake (PLFA) for distribution through the IHSS. Pony Lake is a saline coastal pond on Ross Island, Antarctica, where the landscape is devoid of terrestrial plants. Sample collection occurred over a 17-day period in the summer season at Pony Lake. During this time, the dissolved organic carbon (DOC) concentrations increased nearly two-fold, and the fulvic acid fraction (collected using the XAD-8 method) accounted for 14.6% of the DOC. During the re-concentration and desalting procedures we isolated two other chemically distinct fulvic acid fractions: (1) PLFA-2, which was high in carbohydrates and (2) PLFA-CER, which was high in nitrogen. The chemical characteristics (elemental analysis, optical characterization with UV-vis and fluorescence spectroscopy, and 13C NMR spectroscopy) of the three fulvic acid fractions helped to explain their behavior during isolation.
van der Voet, Hilko; Goedhart, Paul W; Schmidt, Kerstin
2017-11-01
An equivalence testing method is described to assess the safety of regulated products using relevant data obtained in historical studies with assumedly safe reference products. The method is illustrated using data from a series of animal feeding studies with genetically modified and reference maize varieties. Several criteria for quantifying equivalence are discussed, and study-corrected distribution-wise equivalence is selected as being appropriate for the example case study. An equivalence test is proposed based on a high probability of declaring equivalence in a simplified situation, where there is no between-group variation, where the historical and current studies have the same residual variance, and where the current study is assumed to have a sample size as set by a regulator. The method makes use of generalized fiducial inference methods to integrate uncertainties from both the historical and the current data. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.
EGR distribution and fluctuation probe based on CO.sub.2 measurements
Parks, II, James E; Partridge, Jr., William P; Yoo, Ji Hyung
2015-04-07
A diagnostic system having a single-port EGR probe and a method for using the same. The system includes a light source, an EGR probe, a detector and a processor. The light source may provide a combined light beam composed of light from a mid-infrared signal source and a mid-infrared reference source. The signal source may be centered at 4.2 .mu.m and the reference source may be centered at 3.8 .mu.m. The EGR probe may be a single-port probe with internal optics and a sampling chamber with two flow cells arranged along the light path in series. The optics may include a lens for focusing the light beam and a mirror for reflecting the light beam received from a pitch optical cable to a catch optical cable. The signal and reference sources are modulated at different frequencies, thereby allowing them to be separated and the signal normalized by the processor.
Takahashi, Kayori; Kishine, Kana; Matsuyama, Shigetomo; Saito, Takeshi; Kato, Haruhisa; Kinugasa, Shinichi
2008-07-01
Poly(ethylene glycol) (PEG) is a useful water-soluble polymer that has attracted considerable interest in medical and biological science applications as well as in polymer physics. Through the use of a well-calibrated evaporative light-scattering detector coupled with high performance supercritical fluid chromatography, we are able to determine exactly not only the average mass but also all of the molecular mass fractions of PEG samples needed for certified reference materials issued by the National Metrology Institute of Japan. In addition, experimental uncertainty was determined in accordance with the Guide to the expression of uncertainty in measurement (GUM). This reference material can be used to calibrate measuring instruments, to control measurement precision, and to confirm the validity of measurement methods when determining molecular mass distributions and average molecular masses. Especially, it is suitable for calibration against both masses and intensities for matrix-assisted laser desorption/ionization time-of-flight mass spectrometry.
Rubidium distribution at atomic scale in high efficient Cu(In,Ga)Se2 thin-film solar cells
NASA Astrophysics Data System (ADS)
Vilalta-Clemente, Arantxa; Raghuwanshi, Mohit; Duguay, Sébastien; Castro, Celia; Cadel, Emmanuel; Pareige, Philippe; Jackson, Philip; Wuerz, Roland; Hariskos, Dimitrios; Witte, Wolfram
2018-03-01
The introduction of a rubidium fluoride post deposition treatment (RbF-PDT) for Cu(In,Ga)Se2 (CIGS) absorber layers has led to a record efficiency up to 22.6% for thin-film solar cell technology. In the present work, high efficiency CIGS samples with RbF-PDT have been investigated by atom probe tomography (APT) to reveal the atomic distribution of all alkali elements present in CIGS layers and compared with non-treated samples. A Scanning Electron Microscopy Dual beam station (Focused Ion Beam-Gas Injection System) as well as Transmission Kikuchi diffraction is used for atom probe sample preparation and localization of the grain boundaries (GBs) in the area of interest. The analysis of the 3D atomic scale APT reconstructions of CIGS samples with RbF-PDT shows that inside grains, Rb is under the detection limit, but the Na concentration is enhanced as compared to the reference sample without Rb. At the GBs, a high concentration of Rb reaching 1.5 at. % was found, and Na and K (diffusing from the glass substrate) are also segregated at GBs but at lower concentrations as compared to Rb. The intentional introduction of Rb leads to significant changes in the chemical composition of CIGS matrix and at GBs, which might contribute to improve device efficiency.
McCobb, Timothy D.; LeBlanc, Denis R.
2011-01-01
The U.S. Geological Survey (USGS) collected water-quality data between 2001 and 2010 in the Fishermans Cove area of Ashumet Pond, Falmouth, Massachusetts, where the eastern portion of a treated-wastewater plume, created by more than 60 years of overland disposal, discharges to the pond. Temporary drive points were installed, and shallow pond-bottom groundwater was sampled, at 167 locations in 2001, 150 locations in 2003, and 120 locations in 2004 to delineate the distribution of wastewater-related constituents. In 2004, the Air Force Center for Engineering and the Environment (AFCEE) installed a pond-bottom permeable reactive barrier (PRB) to intercept phosphate in the plume at its discharge point to the pond. The USGS monitored the performance of the PRB by collecting samples from temporary drive points at multiple depth intervals in 2006 (200 samples at 76 locations) and 2009 (150 samples at 90 locations). During the first 5 years after installation of the PRB, water samples were collected periodically from five types of pore-water samplers that had been permanently installed in and near the PRB during the barrier's emplacement. The distribution of wastewater-related constituents in the pond-bottom groundwater and changes in the geochemistry of the pond-bottom groundwater after installation of the PRB have been documented in several published reports that are listed in the references.
Nonlinear Spatial Inversion Without Monte Carlo Sampling
NASA Astrophysics Data System (ADS)
Curtis, A.; Nawaz, A.
2017-12-01
High-dimensional, nonlinear inverse or inference problems usually have non-unique solutions. The distribution of solutions are described by probability distributions, and these are usually found using Monte Carlo (MC) sampling methods. These take pseudo-random samples of models in parameter space, calculate the probability of each sample given available data and other information, and thus map out high or low probability values of model parameters. However, such methods would converge to the solution only as the number of samples tends to infinity; in practice, MC is found to be slow to converge, convergence is not guaranteed to be achieved in finite time, and detection of convergence requires the use of subjective criteria. We propose a method for Bayesian inversion of categorical variables such as geological facies or rock types in spatial problems, which requires no sampling at all. The method uses a 2-D Hidden Markov Model over a grid of cells, where observations represent localized data constraining the model in each cell. The data in our example application are seismic properties such as P- and S-wave impedances or rock density; our model parameters are the hidden states and represent the geological rock types in each cell. The observations at each location are assumed to depend on the facies at that location only - an assumption referred to as `localized likelihoods'. However, the facies at a location cannot be determined solely by the observation at that location as it also depends on prior information concerning its correlation with the spatial distribution of facies elsewhere. Such prior information is included in the inversion in the form of a training image which represents a conceptual depiction of the distribution of local geologies that might be expected, but other forms of prior information can be used in the method as desired. The method provides direct (pseudo-analytic) estimates of posterior marginal probability distributions over each variable, so these do not need to be estimated from samples as is required in MC methods. On a 2-D test example the method is shown to outperform previous methods significantly, and at a fraction of the computational cost. In many foreseeable applications there are therefore no serious impediments to extending the method to 3-D spatial models.
Liang, Peng; Wu, Sheng-Chun; Zhang, Jin; Cao, Yucheng; Yu, Shen; Wong, Ming-Hung
2016-04-01
Thirty-six sediment samples were collected from six mariculture sites and corresponding reference sites (approximately 200-300 m away from each mariculture site) to study the effects of mariculture on heavy metal: copper (Cu), zinc (Zn), chromium (Cr) and lead (Pb) distribution in sediments and cultured fish around the Pearl River Delta region, south China. The mean concentrations of Cu, Zn, Cr and Pb in all mariculture sediment samples were 109, 273, 99 and 33 mg/kg, compared with 63, 209, 56 and 23 mg/kg for reference sediment samples, respectively. The Pollution Load Index of sediment for each site was over 1, implying substantial heavy metal pollution. The results of principal component analysis and hierarchical clustering analysis indicate that marine aquaculture activities have enriched the surface sediments underneath mariculture rafts with Cu, Zn and Pb, possibly due to the accumulation of unconsumed fish feeds, fish excreta and antifouling paints (except Cr). Two kinds of fish feeds, feed pellets and trash fish commonly used in Hong Kong were analyzed. The concentrations of Zn and Cu contained in feed pellets were significantly higher (p < 0.05) than in trash fish due to addition of these elements as growth promoters during pellet production. However, the Pb content in trash fish (due to contamination) was significantly higher (p < 0.05) than in feed pellets. Three cultured fish species, namely red snapper (Lutjanus campechanus), orange-spotted grouper (Epinephelus coioides) and snubnose pompano (Trachinotus blochii), were collected from each mariculture site for metal analysis. Lead concentrations in 21 fish samples exceeded the Chinese safety guideline (0.5 mg/kg, GB18406.4-2001), indicating that Pb contamination in cultured fish would be a public health concern. Copyright © 2015. Published by Elsevier Ltd.
Sampling design for spatially distributed hydrogeologic and environmental processes
Christakos, G.; Olea, R.A.
1992-01-01
A methodology for the design of sampling networks over space is proposed. The methodology is based on spatial random field representations of nonhomogeneous natural processes, and on optimal spatial estimation techniques. One of the most important results of random field theory for physical sciences is its rationalization of correlations in spatial variability of natural processes. This correlation is extremely important both for interpreting spatially distributed observations and for predictive performance. The extent of site sampling and the types of data to be collected will depend on the relationship of subsurface variability to predictive uncertainty. While hypothesis formulation and initial identification of spatial variability characteristics are based on scientific understanding (such as knowledge of the physics of the underlying phenomena, geological interpretations, intuition and experience), the support offered by field data is statistically modelled. This model is not limited by the geometric nature of sampling and covers a wide range in subsurface uncertainties. A factorization scheme of the sampling error variance is derived, which possesses certain atttactive properties allowing significant savings in computations. By means of this scheme, a practical sampling design procedure providing suitable indices of the sampling error variance is established. These indices can be used by way of multiobjective decision criteria to obtain the best sampling strategy. Neither the actual implementation of the in-situ sampling nor the solution of the large spatial estimation systems of equations are necessary. The required values of the accuracy parameters involved in the network design are derived using reference charts (readily available for various combinations of data configurations and spatial variability parameters) and certain simple yet accurate analytical formulas. Insight is gained by applying the proposed sampling procedure to realistic examples related to sampling problems in two dimensions. ?? 1992.
Kolachi, Nida Fatima; Kazi, Tasneem Gul; Afridi, Hassan Imran; Kazi, Naveed; Kandhro, Ghulam Abbas; Shah, Abdul Qadir; Baig, Jameel Ahmed; Wadhwa, Sham Kumar; Khan, Sumaira; Shah, Faheem; Jamali, Mohammad Khan; Arain, Mohammad Balal
2011-10-01
The aim of the present study was to compare the level of copper (Cu), iron (Fe) and zinc (Zn) in biological samples (serum, blood, urine, and scalp hair) of patients suffering from different viral hepatitis (A, B, C, D, and E; n = 521) of both gender age ranged 31-45 years. For comparative study, 255 age-matched control subjects, of both genders residing in the same city were selected as referents. The elements in the biological samples were analyzed by flame atomic absorption spectrophotometry, prior to microwave-assisted acid digestion. The validity and accuracy of the methodology was checked by using certified reference materials (CRMs) and with those values obtained by conventional wet acid digestion method on same CRMs. The results of this study showed that the mean values of Cu and Fe were higher in blood, sera, and scalp hair samples of hepatitis patients, while Zn level was found to be lower than age-matched control subjects. The urinary levels of these elements were found to be higher in the hepatitis patients than in the age-matched healthy controls (p < 0.05). These results are consistent with literature-reported data, confirming that the deficiency of zinc and hepatic iron and copper overload can directly cause lipid peroxidation and eventually hepatic damage.
[Determination of trace Cs, Th and U in ten kinds of human autopsy tissues by ICP-MS].
Wang, Jing-yu; Zhu, Hong-da; Ouyang, Li; Liu, Ya-qiong; Wang, Xiao-yan; Huang, Zhuo; Wang, Nai-fen; Liu, Hu-sheng
2004-09-01
This paper studied the trace elements Cs, Th and U in ten kinds of human autopsy tissues by ICP-MS. The instrumental operating conditions were optimized for the measurement of Cs, Th and U. Rhodium (Rh) was used as an internal standard element to compensate matrix effect. Detection limits for Th, U and Cs were 5.7-17.8 pg x mL(-1). The recoveries for spiking liver samples were 96%-107%, and their RSDs were 4.8%-8.9%. Reference materials of NIST SRM 8414 Bovine and NIST SRM 1486 Bone Meal were analyzed by the described method, and the analytical results agreed well with the reference values. Human autopsy tissues samples were digested by mixed acid (HNO3 + HClO4). The determination of Cs, Th and U in lung, liver, bone, heart, stomach, spleen, muscle, kidney, thyroid gland and intestinum tenue was performed by ICP-MS without separation and enrichment procedures. The obtained results indicated that this method is rapid, sensitive and accurate; the distribution of the three elements is different from one to another human organ sample; the main organ targets for Th and U are lungs and kidneys; and a coordinated variation of Cs, Th and U concentration in lungs was found in the samples collected from Hebei and Sichuan provinces.
Le, Margaret; Flores, David; May, Danica; Gourley, Eric; Nangia, Ajay K
2016-05-01
The evaluation and management of male hypogonadism should be based on symptoms and on serum testosterone levels. Diagnostically this relies on accurate testing and reference values. Our objective was to define the distribution of reference values and assays for free and total testosterone by clinical laboratories in the United States. Upper and lower reference values, assay methodology and source of published reference ranges were obtained from laboratories across the country. A standardized survey was reviewed with laboratory staff via telephone. Descriptive statistics were used to tabulate results. We surveyed a total of 120 laboratories in 47 states. Total testosterone was measured in house at 73% of laboratories. At the remaining laboratories studies were sent to larger centralized reference facilities. The mean ± SD lower reference value of total testosterone was 231 ± 46 ng/dl (range 160 to 300) and the mean upper limit was 850 ± 141 ng/dl (range 726 to 1,130). Only 9% of laboratories where in-house total testosterone testing was performed created a reference range unique to their region. Others validated the instrument recommended reference values in a small number of internal test samples. For free testosterone 82% of laboratories sent testing to larger centralized reference laboratories where equilibrium dialysis and/or liquid chromatography with mass spectrometry was done. The remaining laboratories used published algorithms to calculate serum free testosterone. Reference ranges for testosterone assays vary significantly among laboratories. The ranges are predominantly defined by limited population studies of men with unknown medical and reproductive histories. These poorly defined and variable reference values, especially the lower limit, affect how clinicians determine treatment. Copyright © 2016 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.
Laboratory-Based Bidirectional Reflectance Distribution Functions of Radiometric Tarps
NASA Technical Reports Server (NTRS)
Georgiev, Georgi T.; Butler, James J.
2008-01-01
Laboratory-based bidirectional reflectance distribution functions of radiometric tarp samples used in the vicarious calibration of Earth remote sensing satellite instruments are presented in this paper. The results illustrate the BRDF dependence on the orientation of the tarps weft and warp threads. The study was performed using the GSFC scatterometer at incident zenith angles of 0 deg, 10 deg, and 30 deg; scatter zenith angles from 0 deg. to 60 deg.; and scatter azimuth angles of 0 deg., 45 deg., 90 deg., 135 deg. and 180 deg. The wavelengths were 485nm, 550nm, 633nm and 800nm. The tarp's weft and warp dependence on BRDF is well defined at all measurement geometries and wavelengths. The BRDF difference can be as high as 8% at 0o incident angle and 12% at 30 deg. incident angle. The fitted BRDF data shows a very small discrepancy from the measured ones. New data on the forward and backscatter properties of radiometric tarps are reported. The backward scatter is well pronounced for the white samples. The black sample has well pronounced forward scatter. The provided BRDF characterization of radiometric tarps is an excellent reference for anyone interested in using tarps for radiometric calibrations. The results are NIST traceable.
Fatemeh, Dehghan; Reza, Zolfaghari Mohammad; Mohammad, Arjomandzadegan; Salomeh, Kalantari; Reza, Ahmari Gholam; Hossein, Sarmadian; Maryam, Sadrnia; Azam, Ahmadi; Mana, Shojapoor; Negin, Najarian; Reza, Kasravi Alii; Saeed, Falahat
2014-01-01
Objective To analyse molecular detection of coliforms and shorten the time of PCR. Methods Rapid detection of coliforms by amplification of lacZ and uidA genes in a multiplex PCR reaction was designed and performed in comparison with most probably number (MPN) method for 16 artificial and 101 field samples. The molecular method was also conducted on isolated coliforms from positive MPN samples; standard sample for verification of microbial method certificated reference material; isolated strains from certificated reference material and standard bacteria. The PCR and electrophoresis parameters were changed for reducing the operation time. Results Results of PCR for lacZ and uidA genes were similar in all of standard, operational and artificial samples and showed the 876 bp and 147 bp bands of lacZ and uidA genes by multiplex PCR. PCR results were confirmed by MPN culture method by sensitivity 86% (95% CI: 0.71-0.93). Also the total execution time, with a successful change of factors, was reduced to less than two and a half hour. Conclusions Multiplex PCR method with shortened operation time was used for the simultaneous detection of total coliforms and Escherichia coli in distribution system of Arak city. It's recommended to be used at least as an initial screening test, and then the positive samples could be randomly tested by MPN. PMID:25182727
Ghost imaging based on Pearson correlation coefficients
NASA Astrophysics Data System (ADS)
Yu, Wen-Kai; Yao, Xu-Ri; Liu, Xue-Feng; Li, Long-Zhen; Zhai, Guang-Jie
2015-05-01
Correspondence imaging is a new modality of ghost imaging, which can retrieve a positive/negative image by simple conditional averaging of the reference frames that correspond to relatively large/small values of the total intensity measured at the bucket detector. Here we propose and experimentally demonstrate a more rigorous and general approach in which a ghost image is retrieved by calculating a Pearson correlation coefficient between the bucket detector intensity and the brightness at a given pixel of the reference frames, and at the next pixel, and so on. Furthermore, we theoretically provide a statistical interpretation of these two imaging phenomena, and explain how the error depends on the sample size and what kind of distribution the error obeys. According to our analysis, the image signal-to-noise ratio can be greatly improved and the sampling number reduced by means of our new method. Project supported by the National Key Scientific Instrument and Equipment Development Project of China (Grant No. 2013YQ030595) and the National High Technology Research and Development Program of China (Grant No. 2013AA122902).
Microsatellite analysis of Fasciola spp. in Egypt.
Dar, Yasser; Amer, Said; Courtioux, Bertrand; Dreyfuss, Gilles
2011-12-01
Recently, the topic of diversity in Fasciola population in Egypt is controversial. The present study was performed to study the genetic diversity of isolated flukes based on microsatellites markers. Fasciola worms were collected from different hosts and geographical locations in Egypt. Control samples of Fasciola hepatica from France as well as Fasciola gigantica from Cameroon were included in the study. Collected flukes were identified morphologically and subjected for analysis using four microsatellite markers. Results of microsatellite profile (FM1 and FM2) proved that both species of Fasciola are distributed in Egypt irrespective of geographical location and host. Nevertheless, the microsatellite profile of some analyzed loci (FM2 and FM3) proved that Egyptian flukes showed more alleles compared to the reference ones. Differences of microsatellite profile in Egyptian isolates than that of corresponding reference samples indicate the remarkable diversity of these isolates. The present results highlighted the utility of microsatellite profile to discriminate between Fasciola species and to elucidate the diversity within the species. To our knowledge, this is the first time to study microsatellite polymorphism in Fasciola populations in Egypt.
DOE Office of Scientific and Technical Information (OSTI.GOV)
McLoughlin, Kevin
2016-01-11
This report describes the design and implementation of an algorithm for estimating relative microbial abundances, together with confidence limits, using data from metagenomic DNA sequencing. For the background behind this project and a detailed discussion of our modeling approach for metagenomic data, we refer the reader to our earlier technical report, dated March 4, 2014. Briefly, we described a fully Bayesian generative model for paired-end sequence read data, incorporating the effects of the relative abundances, the distribution of sequence fragment lengths, fragment position bias, sequencing errors and variations between the sampled genomes and the nearest reference genomes. A distinctive featuremore » of our modeling approach is the use of a Chinese restaurant process (CRP) to describe the selection of genomes to be sampled, and thus the relative abundances. The CRP component is desirable for fitting abundances to reads that may map ambiguously to multiple targets, because it naturally leads to sparse solutions that select the best representative from each set of nearly equivalent genomes.« less
Quantification of lithium at ppm level in geological samples using nuclear reaction analysis.
De La Rosa, Nathaly; Kristiansson, Per; Nilsson, E J Charlotta; Ros, Linus; Pallon, Jan; Skogby, Henrik
2018-01-01
Proton-induced reaction (p,α) is one type of nuclear reaction analysis (NRA) suitable especially for light element quantification. In the case of lithium quantification presented in this work, accelerated protons with an energy about of 850 keV were used to induce the 7 Li(p,α) 4 He reaction in standard reference and geological samples such as tourmaline and other Li-minerals. It is shown that this technique for lithium quantification allowed for measurement of concentrations down below one ppm. The possibility to relate the lithium content with the boron content in a single analysis was also demonstrated using tourmaline samples, both in absolute concentration and in lateral distribution. In addition, Particle induced X-ray emission (PIXE) was utilized as a complementary IBA technique for simultaneous mapping of elements heavier than sodium.
Low-Bandwidth and Non-Compute Intensive Remote Identification of Microbes from Raw Sequencing Reads
Gautier, Laurent; Lund, Ole
2013-01-01
Cheap DNA sequencing may soon become routine not only for human genomes but also for practically anything requiring the identification of living organisms from their DNA: tracking of infectious agents, control of food products, bioreactors, or environmental samples. We propose a novel general approach to the analysis of sequencing data where a reference genome does not have to be specified. Using a distributed architecture we are able to query a remote server for hints about what the reference might be, transferring a relatively small amount of data. Our system consists of a server with known reference DNA indexed, and a client with raw sequencing reads. The client sends a sample of unidentified reads, and in return receives a list of matching references. Sequences for the references can be retrieved and used for exhaustive computation on the reads, such as alignment. To demonstrate this approach we have implemented a web server, indexing tens of thousands of publicly available genomes and genomic regions from various organisms and returning lists of matching hits from query sequencing reads. We have also implemented two clients: one running in a web browser, and one as a python script. Both are able to handle a large number of sequencing reads and from portable devices (the browser-based running on a tablet), perform its task within seconds, and consume an amount of bandwidth compatible with mobile broadband networks. Such client-server approaches could develop in the future, allowing a fully automated processing of sequencing data and routine instant quality check of sequencing runs from desktop sequencers. A web access is available at http://tapir.cbs.dtu.dk. The source code for a python command-line client, a server, and supplementary data are available at http://bit.ly/1aURxkc. PMID:24391826
Low-bandwidth and non-compute intensive remote identification of microbes from raw sequencing reads.
Gautier, Laurent; Lund, Ole
2013-01-01
Cheap DNA sequencing may soon become routine not only for human genomes but also for practically anything requiring the identification of living organisms from their DNA: tracking of infectious agents, control of food products, bioreactors, or environmental samples. We propose a novel general approach to the analysis of sequencing data where a reference genome does not have to be specified. Using a distributed architecture we are able to query a remote server for hints about what the reference might be, transferring a relatively small amount of data. Our system consists of a server with known reference DNA indexed, and a client with raw sequencing reads. The client sends a sample of unidentified reads, and in return receives a list of matching references. Sequences for the references can be retrieved and used for exhaustive computation on the reads, such as alignment. To demonstrate this approach we have implemented a web server, indexing tens of thousands of publicly available genomes and genomic regions from various organisms and returning lists of matching hits from query sequencing reads. We have also implemented two clients: one running in a web browser, and one as a python script. Both are able to handle a large number of sequencing reads and from portable devices (the browser-based running on a tablet), perform its task within seconds, and consume an amount of bandwidth compatible with mobile broadband networks. Such client-server approaches could develop in the future, allowing a fully automated processing of sequencing data and routine instant quality check of sequencing runs from desktop sequencers. A web access is available at http://tapir.cbs.dtu.dk. The source code for a python command-line client, a server, and supplementary data are available at http://bit.ly/1aURxkc.
Freire, Carmen; Koifman, Rosalina Jorge; Fujimoto, Denys; de Oliveira Souza, Vanessa Cristina; Barbosa, Fernando; Koifman, Sergio
2015-06-01
This study aimed to investigate the distribution and factors influencing blood levels of Cadmium (Cd), Arsenic (As), and Manganese (Mn), and to determine their reference values in a sample of blood donors residing in Rio Branco, capital city of Acre State, Brazil. Blood samples were collected from all blood donors attending the Central Hemotherapic Unit in Rio Branco between 2010 and 2011. Among these, 1183 donors (98.9%) answered to a questionnaire on sociodemographic and lifestyle factors. Blood metal concentrations were determined by atomic spectrometry. Association between Cd, As and Mn levels and donors' characteristics was examined by linear regression analysis. Reference values were estimated as the upper limit of the 95% confidence interval of the 95th percentile of metal levels. References values were 0.87 μg L(-1) for Cd, 9.87 μg L(-1) for As, and 29.32 μg L(-1) for Mn. Reference values of Cd and As in smokers were 2.66 and 10.86 μg L(-1), respectively. Factors contributing to increase Cd levels were smoking, ethnicity (non-white), and lower education, whereas drinking tea and non-bottled water were associated with lower Cd. Lower levels of As were associated with higher household income, living near industrial facilities, working in a glass factory, a compost plant or in metal mining activities. Risk factors for Mn exposure were not identified. In general, blood Cd concentrations were in the range of exposure levels reported for other people from the general population, whereas levels of As and Mn were higher than in other non-occupationally exposed populations elsewhere. Copyright © 2015 Elsevier Ltd. All rights reserved.
IDENTIFICATION OF 1.4 MILLION ACTIVE GALACTIC NUCLEI IN THE MID-INFRARED USING WISE DATA
DOE Office of Scientific and Technical Information (OSTI.GOV)
Secrest, N. J.; Dudik, R. P.; Dorland, B. N.
2015-11-15
We present an all-sky sample of ≈1.4 million active galactic nuclei (AGNs) meeting a two-color infrared photometric selection criteria for AGNs as applied to sources from the Wide-field Infrared Survey Explorer final catalog release (AllWISE). We assess the spatial distribution and optical properties of our sample and find that the results are consistent with expectations for AGNs. These sources have a mean density of ≈38 AGNs per square degree on the sky, and their apparent magnitude distribution peaks at g ≈ 20, extending to objects as faint as g ≈ 26. We test the AGN selection criteria against a largemore » sample of optically identified stars and determine the “leakage” (that is, the probability that a star detected in an optical survey will be misidentified as a quasi-stellar object (QSO) in our sample) rate to be ≤4.0 × 10{sup −5}. We conclude that our sample contains almost no optically identified stars (≤0.041%), making this sample highly promising for future celestial reference frame work as it significantly increases the number of all-sky, compact extragalactic objects. We further compare our sample to catalogs of known AGNs/QSOs and find a completeness value of ≳84% (that is, the probability of correctly identifying a known AGN/QSO is at least 84%) for AGNs brighter than a limiting magnitude of R ≲ 19. Our sample includes approximately 1.1 million previously uncataloged AGNs.« less
Nonprimate Hepaciviruses in Domestic Horses, United Kingdom
Lyons, Sinéad; Kapoor, Amit; Sharp, Colin; Schneider, Bradley S.; Wolfe, Nathan D.; Culshaw, Geoff; Corcoran, Brendan; McGorum, Bruce C.
2012-01-01
Although the origin of hepatitis C virus infections in humans remains undetermined, a close homolog of this virus, termed canine hepacivirus (CHV) and found in respiratory secretions of dogs, provides evidence for a wider distribution of hepaciviruses in mammals. We determined frequencies of active infection among dogs and other mammals in the United Kingdom. Samples from dogs (46 respiratory, 99 plasma, 45 autopsy samples) were CHV negative by PCR. Screening of 362 samples from cats, horses, donkeys, rodents, and pigs identified 3 (2%) positive samples from 142 horses. These samples were genetically divergent from CHV and nonprimate hepaciviruses that horses were infected with during 2012 in New York state, USA. Investigation of infected horses demonstrated nonprimate hepacivirus persistence, high viral loads in plasma (105–107 RNA copies/mL), and liver function test results usually within reference ranges, although several values ranged from high normal to mildly elevated. Disease associations and host range of nonprimate hepaciviruses warrant further investigation. PMID:23171728
Stucke, Kathrin; Kieser, Meinhard
2012-12-10
In the three-arm 'gold standard' non-inferiority design, an experimental treatment, an active reference, and a placebo are compared. This design is becoming increasingly popular, and it is, whenever feasible, recommended for use by regulatory guidelines. We provide a general method to calculate the required sample size for clinical trials performed in this design. As special cases, the situations of continuous, binary, and Poisson distributed outcomes are explored. Taking into account the correlation structure of the involved test statistics, the proposed approach leads to considerable savings in sample size as compared with application of ad hoc methods for all three scale levels. Furthermore, optimal sample size allocation ratios are determined that result in markedly smaller total sample sizes as compared with equal assignment. As optimal allocation makes the active treatment groups larger than the placebo group, implementation of the proposed approach is also desirable from an ethical viewpoint. Copyright © 2012 John Wiley & Sons, Ltd.
Analytical Fingerprint of Wolframite Ore Concentrates.
Gäbler, Hans-Eike; Schink, Wilhelm; Goldmann, Simon; Bahr, Andreas; Gawronski, Timo
2017-07-01
Ongoing violent conflicts in Central Africa are fueled by illegal mining and trading of tantalum, tin, and tungsten ores. The credibility of document-based traceability systems can be improved by an analytical fingerprint applied as an independent method to confirm or doubt the documented origin of ore minerals. Wolframite (Fe,Mn)WO 4 is the most important ore mineral for tungsten and is subject to artisanal mining in Central Africa. Element concentrations of wolframite grains analyzed by laser ablation-inductively coupled plasma-mass spectrometry are used to establish the analytical fingerprint. The data from ore concentrate samples are multivariate, not normal or log-normal distributed. The samples cannot be regarded as representative aliquots of a population. Based on the Kolmogorov-Smirnov distance, a measure of similarity between a sample in question and reference samples from a database is determined. A decision criterion is deduced to recognize samples which do not originate from the declared mine site. © 2017 American Academy of Forensic Sciences.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Maloney, Daniel J; Monazam, Esmail R; Casleton, Kent H
Char samples representing a range of combustion conditions and extents of burnout were obtained from a well-characterized laminar flow combustion experiment. Individual particles from the parent coal and char samples were characterized to determine distributions in particle volume, mass, and density at different extent of burnout. The data were then compared with predictions from a comprehensive char combustion model referred to as the char burnout kinetics model (CBK). The data clearly reflect the particle- to-particle heterogeneity of the parent coal and show a significant broadening in the size and density distributions of the chars resulting from both devolatilization and combustion.more » Data for chars prepared in a lower oxygen content environment (6% oxygen by vol.) are consistent with zone II type combustion behavior where most of the combustion is occurring near the particle surface. At higher oxygen contents (12% by vol.), the data show indications of more burning occurring in the particle interior. The CBK model does a good job of predicting the general nature of the development of size and density distributions during burning but the input distribution of particle size and density is critical to obtaining good predictions. A significant reduction in particle size was observed to occur as a result of devolatilization. For comprehensive combustion models to provide accurate predictions, this size reduction phenomenon needs to be included in devolatilization models so that representative char distributions are carried through the calculations.« less
Quality of Source Water from Public-Supply Wells in the United States, 1993-2007
Toccalino, Patricia L.; Norman, Julia E.; Hitt, Kerie J.
2010-01-01
More than one-third of the Nation's population receives their drinking water from public water systems that use groundwater as their source. The U.S. Geological Survey (USGS) sampled untreated source water from 932 public-supply wells, hereafter referred to as public wells, as part of multiple groundwater assessments conducted across the Nation during 1993-2007. The objectives of this study were to evaluate (1) contaminant occurrence in source water from public wells and the potential significance of contaminant concentrations to human health, (2) national and regional distributions of groundwater quality, and (3) the occurrence and characteristics of contaminant mixtures. Treated finished water was not sampled. The 932 public wells are widely distributed nationally and include wells in selected parts of 41 states and withdraw water from parts of 30 regionally extensive aquifers used for public water supply. These wells are distributed among 629 unique public water systems-less than 1 percent of all groundwater-supplied public water systems in the United States-but the wells were randomly selected within the sampled hydrogeologic settings to represent typical aquifer conditions. Samples from the 629 systems represent source water used by one-quarter of the U.S. population served by groundwater-supplied public water systems, or about 9 percent of the entire U.S. population in 2008. One groundwater sample was collected prior to treatment or blending from each of the 932 public wells and analyzed for as many as six water-quality properties and 215 contaminants. Consistent with the terminology used in the Safe Drinking Water Act (SDWA), all constituents analyzed in water samples in this study are referred to as 'contaminants'. More contaminant groups were assessed in this study than in any previous national study of public wells and included major ions, nutrients, radionuclides, trace elements, pesticide compounds, volatile organic compounds (VOCs), and fecal-indicator microorganisms. Contaminant mixtures were assessed in subsets of samples in which most contaminants were analyzed. Contaminant concentrations were compared to human-health benchmarks-regulatory U.S. Environmental Protection Agency (USEPA) Maximum Contaminant Levels (MCLs) for contaminants regulated in drinking water under the SDWA or non-regulatory USGS Health-Based Screening Levels (HBSLs) for unregulated contaminants, when available. Nearly three-quarters of the contaminants assessed in this study are unregulated in drinking water, and the USEPA uses USGS data on the occurrence of unregulated contaminants in water resources to fulfill part of the SDWA requirements for determining whether specific contaminants should be regulated in drinking water in the future. More than one in five (22 percent) source-water samples from public wells contained one or more naturally occurring or man-made contaminants at concentrations greater than human-health benchmarks, and 80 percent of samples contained one or more contaminants at concentrations greater than one-tenth of benchmarks. Most individual contaminant detections, however, were less than one-tenth of human-health benchmarks. Public wells yielding water with contaminant concentrations greater than benchmarks, as well as those with concentrations greater than one-tenth of benchmarks, were distributed throughout the United States and included wells that withdraw water from all principal aquifer rock types included in this study. Ten contaminants individually were detected at concentrations greater than human-health benchmarks in at least 1 percent of source-water samples and collectively accounted for most concentrations greater than benchmarks. Seven of these 10 contaminants occur naturally, including three radionuclides (radon, radium, and gross alpha-particle radioactivity) and four trace elements (arsenic, manganese, strontium, and boron); three of these 10 contaminants (dieldrin, nitrate, and perchl
Seasonal distribution and demographical characteristics of carpal tunnel syndrome in 1039 patients.
Gomes, Irênio; Becker, Jefferson; Ehlers, João Arthur; Kapczinski, Flávio; Nora, Daniel Bocchese
2004-09-01
To describe the demographic characteristics of gender, age, and presence of repetitive movements, intake of alcohol and non-steroid anti-inflammatories (NSAI), medical specialties that referred patients to nerve conduction studies and electromyography (NCS-EMG), school attainment, and seasonal distribution in patients with a neurophysiological diagnosis of carpal tunnel syndrome (CTS) in the State of Rio Grande do Sul, Brazil. A series of 1039 patients (1549 hands) with neurophysiologically defined CTS was studied. Patients were referred for NCS-EMG in 3 universities and 2 private services, from August 2001 to January 2003. All patients completed a questionnaire containing demographic information. The diagnosis of CTS was established following a pre-established protocol, with defined diagnostic criteria. Around one fourth of patients had already performed NCS-EMG; the greatest frequency of CTS was observed in women (5.6:1) and in patients above the age of 40. Most patients reported performing repetitive movements in their daily routine (69.7%); 12.9% reported use of NSAI and 14.9% regular intake of alcoholic beverages. A greater frequency of CTS was observed in the months of July and August, when compared to the other months of the year. Around 2/3 of the study population had completed at least secondary school. Most requests of nerve conduction studies did not provide a diagnostic hypothesis (59.9%) and neurophysiologic studies were requested mostly by traumatology/orthopedics (71.1%). We have concluded that, in our environment, CTS shows some demographical characteristics that are similar to what the literature describes. Also, we have found that most of our sample concluded at least secondary school, and was referred to neurophysiologic studies by orthopedists. To be pointed out is the seasonal distribution of CTS, which demonstrates a significant association with winter months.
Sample size of the reference sample in a case-augmented study.
Ghosh, Palash; Dewanji, Anup
2017-05-01
The case-augmented study, in which a case sample is augmented with a reference (random) sample from the source population with only covariates information known, is becoming popular in different areas of applied science such as pharmacovigilance, ecology, and econometrics. In general, the case sample is available from some source (for example, hospital database, case registry, etc.); however, the reference sample is required to be drawn from the corresponding source population. The required minimum size of the reference sample is an important issue in this regard. In this work, we address the minimum sample size calculation and discuss related issues. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.
Automatic HTS force measurement instrument
Sanders, S.T.; Niemann, R.C.
1999-03-30
A device is disclosed for measuring the levitation force of a high temperature superconductor sample with respect to a reference magnet includes a receptacle for holding several high temperature superconductor samples each cooled to superconducting temperature. A rotatable carousel successively locates a selected one of the high temperature superconductor samples in registry with the reference magnet. Mechanism varies the distance between one of the high temperature superconductor samples and the reference magnet, and a sensor measures levitation force of the sample as a function of the distance between the reference magnet and the sample. A method is also disclosed. 3 figs.
Fiber optic reference frequency distribution to remote beam waveguide antennas
NASA Technical Reports Server (NTRS)
Calhoun, Malcolm; Kuhnle, Paul; Law, Julius
1995-01-01
In the NASA/JPL Deep Space Network (DSN), radio science experiments (probing outer planet atmospheres, rings, gravitational waves, etc.) and very long-base interferometry (VLBI) require ultra-stable, low phase noise reference frequency signals at the user locations. Typical locations for radio science/VLBI exciters and down-converters are the cone areas of the 34 m high efficiency antennas or the 70 m antennas, located several hundred meters from the reference frequency standards. Over the past three years, fiber optic distribution links have replaced coaxial cable distribution for reference frequencies to these antenna sites. Optical fibers are the preferred medium for distribution because of their low attenuation, immunity to EMI/IWI, and temperature stability. A new network of Beam Waveguide (BWG) antennas presently under construction in the DSN requires hydrogen maser stability at tens of kilometers distance from the frequency standards central location. The topic of this paper is the design and implementation of an optical fiber distribution link which provides ultra-stable reference frequencies to users at a remote BWG antenna. The temperature profile from the earth's surface to a depth of six feet over a time period of six months was used to optimize the placement of the fiber optic cables. In-situ evaluation of the fiber optic link performance indicates Allan deviation on the order of parts in 10(exp -15) at 1000 and 10,000 seconds averaging time; thus, the link stability degradation due to environmental conditions still preserves hydrogen maser stability at the user locations. This paper reports on the implementation of optical fibers and electro-optic devices for distributing very stable, low phase noise reference signals to remote BWG antenna locations. Allan deviation and phase noise test results for a 16 km fiber optic distribution link are presented in the paper.
Fiber optic reference frequency distribution to remote beam waveguide antennas
NASA Astrophysics Data System (ADS)
Calhoun, Malcolm; Kuhnle, Paul; Law, Julius
1995-05-01
In the NASA/JPL Deep Space Network (DSN), radio science experiments (probing outer planet atmospheres, rings, gravitational waves, etc.) and very long-base interferometry (VLBI) require ultra-stable, low phase noise reference frequency signals at the user locations. Typical locations for radio science/VLBI exciters and down-converters are the cone areas of the 34 m high efficiency antennas or the 70 m antennas, located several hundred meters from the reference frequency standards. Over the past three years, fiber optic distribution links have replaced coaxial cable distribution for reference frequencies to these antenna sites. Optical fibers are the preferred medium for distribution because of their low attenuation, immunity to EMI/IWI, and temperature stability. A new network of Beam Waveguide (BWG) antennas presently under construction in the DSN requires hydrogen maser stability at tens of kilometers distance from the frequency standards central location. The topic of this paper is the design and implementation of an optical fiber distribution link which provides ultra-stable reference frequencies to users at a remote BWG antenna. The temperature profile from the earth's surface to a depth of six feet over a time period of six months was used to optimize the placement of the fiber optic cables. In-situ evaluation of the fiber optic link performance indicates Allan deviation on the order of parts in 10(exp -15) at 1000 and 10,000 seconds averaging time; thus, the link stability degradation due to environmental conditions still preserves hydrogen maser stability at the user locations. This paper reports on the implementation of optical fibers and electro-optic devices for distributing very stable, low phase noise reference signals to remote BWG antenna locations. Allan deviation and phase noise test results for a 16 km fiber optic distribution link are presented in the paper.
NASA Astrophysics Data System (ADS)
Castelletti, Davide; Demir, Begüm; Bruzzone, Lorenzo
2014-10-01
This paper presents a novel semisupervised learning (SSL) technique defined in the context of ɛ-insensitive support vector regression (SVR) to estimate biophysical parameters from remotely sensed images. The proposed SSL method aims to mitigate the problems of small-sized biased training sets without collecting any additional samples with reference measures. This is achieved on the basis of two consecutive steps. The first step is devoted to inject additional priors information in the learning phase of the SVR in order to adapt the importance of each training sample according to distribution of the unlabeled samples. To this end, a weight is initially associated to each training sample based on a novel strategy that defines higher weights for the samples located in the high density regions of the feature space while giving reduced weights to those that fall into the low density regions of the feature space. Then, in order to exploit different weights for training samples in the learning phase of the SVR, we introduce a weighted SVR (WSVR) algorithm. The second step is devoted to jointly exploit labeled and informative unlabeled samples for further improving the definition of the WSVR learning function. To this end, the most informative unlabeled samples that have an expected accurate target values are initially selected according to a novel strategy that relies on the distribution of the unlabeled samples in the feature space and on the WSVR function estimated at the first step. Then, we introduce a restructured WSVR algorithm that jointly uses labeled and unlabeled samples in the learning phase of the WSVR algorithm and tunes their importance by different values of regularization parameters. Experimental results obtained for the estimation of single-tree stem volume show the effectiveness of the proposed SSL method.
Ozbek, Nil; Akman, Suleyman
2016-11-15
This study describes the applicability of solid sampling technique for the determination of fluorine in various baby foods via molecular absorption of calcium monofluoride generated in a graphite furnace of high-resolution continuum source atomic absorption spectrometry. Fluorine was determined at CaF wavelength, 606.440nm in a graphite tube applying a pyrolysis temperature of 1000°C and a molecule forming temperature of 2200°C. The limit of detection and characteristic mass of the method were 0.20ng and 0.17ng of fluorine, respectively. The fluorine concentrations determined in standard reference sample (bush branches and leaves) were in good agreement with the certified values. By applying the optimized parameters, the concentration of fluorine in various baby foods were determined. The fluorine concentrations were ranged from
Ottaway, Josh; Farrell, Jeremy A; Kalivas, John H
2013-02-05
An essential part to calibration is establishing the analyte calibration reference samples. These samples must characterize the sample matrix and measurement conditions (chemical, physical, instrumental, and environmental) of any sample to be predicted. Calibration usually requires measuring spectra for numerous reference samples in addition to determining the corresponding analyte reference values. Both tasks are typically time-consuming and costly. This paper reports on a method named pure component Tikhonov regularization (PCTR) that does not require laboratory prepared or determined reference values. Instead, an analyte pure component spectrum is used in conjunction with nonanalyte spectra for calibration. Nonanalyte spectra can be from different sources including pure component interference samples, blanks, and constant analyte samples. The approach is also applicable to calibration maintenance when the analyte pure component spectrum is measured in one set of conditions and nonanalyte spectra are measured in new conditions. The PCTR method balances the trade-offs between calibration model shrinkage and the degree of orthogonality to the nonanalyte content (model direction) in order to obtain accurate predictions. Using visible and near-infrared (NIR) spectral data sets, the PCTR results are comparable to those obtained using ridge regression (RR) with reference calibration sets. The flexibility of PCTR also allows including reference samples if such samples are available.
Modeling and comparative study of fluid velocities in heterogeneous rocks
NASA Astrophysics Data System (ADS)
Hingerl, Ferdinand F.; Romanenko, Konstantin; Pini, Ronny; Balcom, Bruce; Benson, Sally
2013-04-01
Detailed knowledge of the distribution of effective porosity and fluid velocities in heterogeneous rock samples is crucial for understanding and predicting spatially resolved fluid residence times and kinetic reaction rates of fluid-rock interactions. The applicability of conventional MRI techniques to sedimentary rocks is limited by internal magnetic field gradients and short spin relaxation times. The approach developed at the UNB MRI Centre combines the 13-interval Alternating-Pulsed-Gradient Stimulated-Echo (APGSTE) scheme and three-dimensional Single Point Ramped Imaging with T1 Enhancement (SPRITE). These methods were designed to reduce the errors due to effects of background gradients and fast transverse relaxation. SPRITE is largely immune to time-evolution effects resulting from background gradients, paramagnetic impurities and chemical shift. Using these techniques quantitative 3D porosity maps as well as single-phase fluid velocity fields in sandstone core samples were measured. Using a new Magnetic Resonance Imaging technique developed at the MRI Centre at UNB, we created 3D maps of porosity distributions as well as single-phase fluid velocity distributions of sandstone rock samples. Then, we evaluated the applicability of the Kozeny-Carman relationship for modeling measured fluid velocity distributions in sandstones samples showing meso-scale heterogeneities using two different modeling approaches. The MRI maps were used as reference points for the modeling approaches. For the first modeling approach, we applied the Kozeny-Carman relationship to the porosity distributions and computed respective permeability maps, which in turn provided input for a CFD simulation - using the Stanford CFD code GPRS - to compute averaged velocity maps. The latter were then compared to the measured velocity maps. For the second approach, the measured velocity distributions were used as input for inversely computing permeabilities using the GPRS CFD code. The computed permeabilities were then correlated with the ones based on the porosity maps and the Kozeny-Carman relationship. The findings of the comparative modeling study are discussed and its potential impact on the modeling of fluid residence times and kinetic reaction rates of fluid-rock interactions in rocks containing meso-scale heterogeneities are reviewed.
[Expression of neuropeptide Y and long leptin receptor in gastrointestinal tract of giant panda].
Luo, Qihui; Tang, Xiuying; Chen, Zhengli; Wang, Kaiyu; Wang, Chengdong; Li, Desheng; Li, Caiwu
2015-08-01
To study the expression and distribution of neuropeptide Y (NPY) and long leptin receptor (OB-Rb) in the gastrointestinal tract of giant panda, samples of three animals were collected from the key laboratory for reproduction and conservation genetics of endangered wildlife of Sichuan province, China conservation and research center for the giant panda. Paraffin sections of giant panda gastrointestinal tissue samples were observed using hematoxylin-eosin staining (HE) and strept actividin-biotin complex immunohistochemical staining (IHC). The results show that the intestinal histology of three pandas was normal and no pathological changes, and there were rich single-cell and multi-cell mucous glands, long intestinal villi and thick muscularis mucosa and muscle layer. Positive cells expressing NPY and OB-Rb were widely detected in the gastrointestinal tract by IHC methods. NPY positive nerve fibers and neuronal cell were widely distributed in submucosal plexus and myenteric plexus, especially in the former. They were arranged beaded or point-like shape. NPY positive cells were observed in the shape of ellipse and polygon and mainly located in the mucous layer and intestinal glands. OB-Rb positive cells were mainly distributed in the mucous layer and the laminae propria, especially the latter. These results confirmed that NPY and OB-Rb are widely distributed in the gut of the giant panda, which provide strong reference for the research between growth and development, digestion and absorption, and immune function.
Gyhlesten Back, Jessica; Engberg, Göran
2017-01-01
Crystallographic reconstruction of parent austenite grain boundaries from the martensitic microstructure in a wear resistant steel was carried out using electron backscattered diffraction (EBSD). The present study mainly aims to investigate the parent austenite grains from the martensitic structure in an as-rolled (reference) steel sample and samples obtained by quenching at different cooling rates with corresponding dilatometry. Subsequently, this study is to correlate the nearest cooling rate by the dilatometer which yields a similar orientation relationship and substructure as the reference sample. The Kurdjumov-Sachs orientation relationship was used to reconstruct the parent austenite grain boundaries from the martensite boundaries in both reference and dilatometric samples using EBSD crystallographic data. The parent austenite grain boundaries were successfully evaluated from the EBSD data and the corresponding grain sizes were measured. The parent austenite grain boundaries of the reference sample match the sample quenched at 100 °C/s (CR100). Also the martensite substructures and crystallographic textures are similar in these two samples. The results from hardness measurements show that the reference sample exhibits higher hardness than the CR100 sample due to the presence of carbides in the reference sample. PMID:28772813
Gyhlesten Back, Jessica; Engberg, Göran
2017-04-26
Crystallographic reconstruction of parent austenite grain boundaries from the martensitic microstructure in a wear resistant steel was carried out using electron backscattered diffraction (EBSD). The present study mainly aims to investigate the parent austenite grains from the martensitic structure in an as-rolled (reference) steel sample and samples obtained by quenching at different cooling rates with corresponding dilatometry. Subsequently, this study is to correlate the nearest cooling rate by the dilatometer which yields a similar orientation relationship and substructure as the reference sample. The Kurdjumov-Sachs orientation relationship was used to reconstruct the parent austenite grain boundaries from the martensite boundaries in both reference and dilatometric samples using EBSD crystallographic data. The parent austenite grain boundaries were successfully evaluated from the EBSD data and the corresponding grain sizes were measured. The parent austenite grain boundaries of the reference sample match the sample quenched at 100 °C/s (CR100). Also the martensite substructures and crystallographic textures are similar in these two samples. The results from hardness measurements show that the reference sample exhibits higher hardness than the CR100 sample due to the presence of carbides in the reference sample.
Distributing Frequency And Time Signals On Optical Fibers
NASA Technical Reports Server (NTRS)
Lutes, George F.
1993-01-01
Paper reports progress in distribution of frequency and time reference signals over optical fibers. Describes current performance at frequencies of 100 MHz, 1 GHz, and 8.4 GHz. Also describes transmitting and receiving equipment and discusses tradeoff between cost and performance. Concludes with discussion of likely future development and effects of developments on systems using distributed frequency reference signals.
Neves, Vinicius M; Heidrich, Graciela M; Hanzel, Flavia B; Muller, Edson I; Dressler, Valderi L
2018-05-01
Rare earth elements (REEs) have several applications but the effects on environment are not well known. Therefore, the aim of this work is to establish a method for direct solid sample analysis by laser ablation-inductively coupled plasma mass spectrometry (LA-ICP-MS) to evaluate the concentration and distribution of REEs in cultivated and non-cultivated soil. Samples were collected in two areas to 40 cm of depth. The LA-ICP-MS method is easy to be implemented and the sample treatment is very fast comprising only its drying, grounding and pressing as a pellet. The accuracy of the method was evaluated by using a certified reference material (BCR 667 - Estuarine Sediment, Institute for Reference Materials and Measurements (IRMM)) where good agreement with the certified values was obtained. Analyte recovery at two levels of concentration (2.5 and 15.0 μg g -1 ) was also performed and recoveries in the range of 85%-120% were achieved, values that are acceptable for LA-ICP-MS analysis. In general, the concentration of the REEs is higher in the cultivated soil and increased from the surface to deeper layers, which can be a consequence of fertilizer application. Copyright © 2018 Elsevier Ltd. All rights reserved.
Karbasy, Kimiya; Lin, Danny C C; Stoianov, Alexandra; Chan, Man Khun; Bevilacqua, Victoria; Chen, Yunqi; Adeli, Khosrow
2016-04-01
The CALIPER program is a national research initiative aimed at closing the gaps in pediatric reference intervals. CALIPER previously reported reference intervals for endocrine and special chemistry markers on Abbott immunoassays. We now report new pediatric reference intervals for immunoassays on the Beckman Coulter Immunoassay Systems and assess platform-specific differences in reference values. A total of 711 healthy children and adolescents from birth to <19 years of age were recruited from the community. Serum samples were collected for measurement of 29 biomarkers on the Beckman Coulter Immunoassay Systems. Statistically relevant age and/or gender-based partitions were determined, outliers removed, and reference intervals calculated in accordance with Clinical and Laboratory Standards Institute (CLSI) EP28-A3c guidelines. Complex profiles were observed for all 29 analytes, necessitating unique age and/or sex-specific partitions. Overall, changes in analyte concentrations observed over the course of development were similar to trends previously reported, and are consistent with biochemical and physiological changes that occur during childhood. Marked differences were observed for some assays including progesterone, luteinizing hormone and follicle-stimulating hormone where reference intervals were higher than those reported on Abbott immunoassays and parathyroid hormone where intervals were lower. This study highlights the importance of determining reference intervals specific for each analytical platform. The CALIPER Pediatric Reference Interval database will enable accurate diagnosis and laboratory assessment of children monitored by Beckman Coulter Immunoassay Systems in health care institutions worldwide. These reference intervals must however be validated by individual labs for the local pediatric population as recommended by CLSI.
Tests for qualitative treatment-by-centre interaction using a 'pushback' procedure.
Ciminera, J L; Heyse, J F; Nguyen, H H; Tukey, J W
1993-06-15
In multicentre clinical trials using a common protocol, the centres are usually regarded as being a fixed factor, thus allowing any treatment-by-centre interaction to be omitted from the error term for the effect of treatment. However, we feel it necessary to use the treatment-by-centre interaction as the error term if there is substantial evidence that the interaction with centres is qualitative instead of quantitative. To make allowance for the estimated uncertainties of the centre means, we propose choosing a reference value (for example, the median of the ordered array of centre means) and converting the individual centre results into standardized deviations from the reference value. The deviations are then reordered, and the results 'pushed back' by amounts appropriate for the corresponding order statistics in a sample from the relevant distribution. The pushed-back standardized deviations are then restored to the original scale. The appearance of opposite signs among the destandardized values for the various centres is then taken as 'substantial evidence' of qualitative interaction. Procedures are presented using, in any combination: (i) Gaussian, or Student's t-distribution; (ii) order-statistic medians or outward 90 per cent points of the corresponding order statistic distributions; (iii) pooling or grouping and pooling the internally estimated standard deviations of the centre means. The use of the least conservative combination--Student's t, outward 90 per cent points, grouping and pooling--is recommended.
Spin Rate Distribution of Small Asteroids Shaped by YORP Effect
NASA Astrophysics Data System (ADS)
Pravec, Petr
2008-09-01
We studied a distribution of spin rates of main belt/Mars crossing (MB/MC) asteroids with diameters 3-15 km using data obtained within the Photometric Survey of Asynchronous Binary Asteroids (Pravec et al. 2008). We found that the spin distribution of the small asteroids is uniform in the range from f = 1 to 9.5 d-1, and there is an excess of slow rotators with f < 1 d-1. The observed distribution appears to be controlled by the Yarkovsky-O'Keefe-Radzievskii-Paddack (YORP) effect. The magnitude of the excess of slow rotators is related to the residence time of slowed down asteroids in the excess and the rate of spin rate change outside the excess. We estimated a median YORP spin rate change of 0.022 d-1/Myr for asteroids in our sample (i.e., a median time in which the spin rate changes by 1 d-1 is 45 Myr), thus the residence time of slowed down asteroids in the excess is 110 Myr. The spin rate distribution of near-Earth asteroids (NEAs) with sizes in the range 0.2-3 km ( 5-times smaller in median diameter than the MB/MC asteroids sample) shows a similar excess of slow rotators, but there is also a concentration of NEAs at fast spin rates with f = 9-10 d-1. The concentration at fast spin rates is correlated with a narrower distribution of spin rates of primaries of binary systems among NEAs; the difference may be due to the apparently more evolved population of binaries among MB/MC asteroids. Reference: Pravec, P., and 30 colleagues, 2008. Spin rate distribution of small asteroids. Icarus, in press. DOI: http://dx.doi.org/10.1016/j.icarus.2008.05.012
de Araújo, Tais Pinheiro; Rodrigues, Sueli Guerreiro; Costa, Maria Irene Weyl de A; Vasconcelos, Pedro Fernando da Costa; da Rosa, Amélia P A Travassos
2002-01-01
From June to December 1999, 785 serum samples were obtained from patients clinically suspected of having dengue or yellow fever. The patients were referred by public health centers distributed within the six mesoregions of Par State, Brazil. Serum samples were tested for Flavivirus antibodies by hemagglutination inhibition test and for dengue and yellow fever viruses by enzyme-linked immunosorbent assay for IgM detection. Of the sera collected, 563 (71.7%) were positive by HI test and out of these 150 (26.6%) were positive by ELISA-IgM. Dengue virus was responsible for most of the recent infections in all regions; yellow fever cases detected in the current study were restricted to the Maraj and Southeast regions.
Component pattern analysis of chemicals using multispectral THz imaging system
NASA Astrophysics Data System (ADS)
Kawase, Kodo; Ogawa, Yuichi; Watanabe, Yuki
2004-04-01
We have developed a novel basic technology for terahertz (THz) imaging, which allows detection and identification of chemicals by introducing the component spatial pattern analysis. The spatial distributions of the chemicals were obtained from terahertz multispectral transillumination images, using absorption spectra previously measured with a widely tunable THz-wave parametric oscillator. Further we have applied this technique to the detection and identification of illicit drugs concealed in envelopes. The samples we used were methamphetamine and MDMA, two of the most widely consumed illegal drugs in Japan, and aspirin as a reference.
Validating Reference Equations for Impulse Oscillometry in Healthy Mexican Children.
Gochicoa-Rangel, Laura; Del Río-Hidalgo, Rodrigo; Hernández-Ruiz, Juana; Rodríguez-Moreno, Luis; Martínez-Briseño, David; Mora-Romero, Uri; Cid-Juárez, Silvia; García-Sancho, Cecilia; Torre-Bouscoulet, Luis
2017-09-01
The impulse oscillometry system (IOS) measures the impedance (Z) of the respiratory system, but proper interpretation of its results requires adequate reference values. The objectives of this work were: (1) to validate the reference equations for the IOS published previously by our group and (2) to compare the adjustment of new available reference equations for the IOS from different countries in a sample of healthy children. Subjects were healthy 4-15-y-old children from the metropolitan area of Mexico City, who performed an IOS test. The functional IOS parameters obtained were compared with the predicted values from 12 reference equations determined in studies of different ethnic groups. The validation methods applied were: analysis of the differences between measured and predicted values for each reference equation; correlation and concordance coefficients; adjustment by Z-score values; percentage of predicted value; and the percentage of patients below the lower limit of normality or above the upper limit of normality. Of the 224 participants, 117 (52.3%) were girls, and the mean age was 8.6 ± 2.3 y. The equations that showed the best adjustment for the different parameters were those from the studies by Nowowiejska et al (2008) and Gochicoa et al (2015). The equations proposed by Frei et al (2005), Hellinckx et al (1998), Kalhoff et al (2011), Klug and Bisgaard (1998), de Assumpção et al (2016), and Dencker et al (2006) overestimated the airway resistance of the children in our sample, whereas the equation of Amra et al (2008) underestimated it. In the analysis of the lower and upper limits of normality, Gochicoa et al equation was the closest, since 5% of subjects were below or above percentiles 5 and 95, respectively. The study found that, in general, all of the equations showed greater error at the extremes of the age distribution. Because of the robust adjustment of the present study reference equations for the IOS, it can be recommended for both clinical and research purposes in our population. The differential adjustment of other equations underlines the need to obtain local reference values. Copyright © 2017 by Daedalus Enterprises.
Encounter risk analysis of rainfall and reference crop evapotranspiration in the irrigation district
NASA Astrophysics Data System (ADS)
Zhang, Jinping; Lin, Xiaomin; Zhao, Yong; Hong, Yang
2017-09-01
Rainfall and reference crop evapotranspiration are random but mutually affected variables in the irrigation district, and their encounter situation can determine water shortage risks under the contexts of natural water supply and demand. However, in reality, the rainfall and reference crop evapotranspiration may have different marginal distributions and their relations are nonlinear. In this study, based on the annual rainfall and reference crop evapotranspiration data series from 1970 to 2013 in the Luhun irrigation district of China, the joint probability distribution of rainfall and reference crop evapotranspiration are developed with the Frank copula function. Using the joint probability distribution, the synchronous-asynchronous encounter risk, conditional joint probability, and conditional return period of different combinations of rainfall and reference crop evapotranspiration are analyzed. The results show that the copula-based joint probability distributions of rainfall and reference crop evapotranspiration are reasonable. The asynchronous encounter probability of rainfall and reference crop evapotranspiration is greater than their synchronous encounter probability, and the water shortage risk associated with meteorological drought (i.e. rainfall variability) is more prone to appear. Compared with other states, there are higher conditional joint probability and lower conditional return period in either low rainfall or high reference crop evapotranspiration. For a specifically high reference crop evapotranspiration with a certain frequency, the encounter risk of low rainfall and high reference crop evapotranspiration is increased with the decrease in frequency. For a specifically low rainfall with a certain frequency, the encounter risk of low rainfall and high reference crop evapotranspiration is decreased with the decrease in frequency. When either the high reference crop evapotranspiration exceeds a certain frequency or low rainfall does not exceed a certain frequency, the higher conditional joint probability and lower conditional return period of various combinations likely cause a water shortage, but the water shortage is not severe.
NASA Astrophysics Data System (ADS)
Cheng, Hok-Chuen
This thesis summaries the measurements of correlations between Lambda 0Lambda0, Lambda0Lambda 0, and Lambda0Lambda 0 hyperon pairs produced inclusively at the LHC, which are useful for a better understanding of the quark-antiquark pair production and jet fragmentation and hadronization processes. The analysis is based on hyperon pairs selected using the muon and minimum bias data samples collected at the ATLAS experiment from proton-proton collisions at a center-of-mass energy of 7 TeV in 2010. Excess Lambda0Lambda 0 are observed near the production threshold and are identified to be originated from the parton system in the string model in the MC sample, decaying either directly or through heavy strange resonances such as Sigma0 and Sigma*(1385). Dynamical correlations have been explored through a correlation function defined as the ratio of two-particle to single-particle densities. Positive correlation is observed for Lambda0Lambda0 and anticorrelation is observed for Lambda0Lambda 0 and Lambda0Lambda 0 for Q in [0,2] GeV. The structure replicates similar correlations in pp, pp, and pppp events in PYTHIA generator as predicted by the Lund string fragmentation model. Parameters of the "popcorn" mechanism implemented in the PYTHIA generator are tuned and are found to have little impact on the structure observed. The spin composition of the sample is extracted using a data-driven reference sample built by event mixing. Appropriate corrections have been made to the kinematic distributions in the reference sample by kinematic weighting to make sure that the detector effects are well modeled. A modified Pearson's chi2 test statistics is calculated for the costheta* distribution to determine the best-fitted A-value for data. The results are consistent with zero for both like-type and unlike-type hyperon pairs in Q ∈ [0,10] GeV and Q ∈ [1,10] GeV respectively. The data statistics in the range of Q ∈ [0, 1] GeV is currently too low for the estimation of the emitter size for Fermi-Dirac correlation.
Zbawicka, Małgorzata; Trucco, María I; Wenne, Roman
2018-02-22
Throughout the world, harvesting of mussels Mytilus spp. is based on the exploitation of natural populations and aquaculture. Aquaculture activities include transfers of spat and live adult mussels between various geographic locations, which may result in large-scale changes in the world distribution of Mytilus taxa. Mytilus taxa are morphologically similar and difficult to distinguish. In spite of much research on taxonomy, evolution and geographic distribution, the native Mytilus taxa of the Southern Hemisphere are poorly understood. Recently, single nucleotide polymorphisms (SNPs) have been used to clarify the taxonomic status of populations of smooth shelled mussels from the Pacific coast of South America. In this paper, we used a set of SNPs to characterize, for the first time, populations of smooth shelled mussels Mytilus from the Atlantic coast of South America. Mytilus spp. samples were collected from eastern South America. Six reference samples from the Northern Hemisphere were used: Mytilus edulis from USA and Northern Ireland, Mytilus trossulus from Canada, and Mytilus galloprovincialis from Spain and Italy. Two other reference samples from the Southern Hemisphere were included: M. galloprovincialis from New Zealand and Mytilus chilensis from Chile. Fifty-five SNPs were successfully genotyped, of which 51 were polymorphic. Population genetic analyses using the STRUCTURE program revealed the clustering of eight populations from Argentina (Mytilus platensis) and the clustering of the sample from Ushuaia with M. chilensis from Chile. All individuals in the Puerto Madryn (Argentina) sample were identified as M. platensis × M. galloprovincialis F2 (88.89%) hybrids, except one that was classified as Mediterranean M. galloprovincialis. No F1 hybrids were observed. We demonstrate that M. platensis (or Mytilus edulis platensis) and M. chilensis are distinct native taxa in South America, which indicates that the evolutionary histories of Mytilus taxa along the Atlantic and Pacific coasts differ. M. platensis is endangered by hybridization with M. galloprovincialis that was introduced from Europe into the Puerto Madryn area in Argentina, presumably by accidental introduction via ship traffic. We confirm the occurrence of a native M. chilensis population in southern Argentina on the coast of Patagonia.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Saleh, Ahmed A., E-mail: asaleh@uow.edu.au
Even with the use of X-ray polycapillary lenses, sample tilting during pole figure measurement results in a decrease in the recorded X-ray intensity. The magnitude of this error is affected by the sample size and/or the finite detector size. These errors can be typically corrected by measuring the intensity loss as a function of the tilt angle using a texture-free reference sample (ideally made of the same alloy as the investigated material). Since texture-free reference samples are not readily available for all alloys, the present study employs an empirical procedure to estimate the correction curve for a particular experimental configuration.more » It involves the use of real texture-free reference samples that pre-exist in any X-ray diffraction laboratory to first establish the empirical correlations between X-ray intensity, sample tilt and their Bragg angles and thereafter generate correction curves for any Bragg angle. It will be shown that the empirically corrected textures are in very good agreement with the experimentally corrected ones. - Highlights: •Sample tilting during X-ray pole figure measurement leads to intensity loss errors. •Texture-free reference samples are typically used to correct the pole figures. •An empirical correction procedure is proposed in the absence of reference samples. •The procedure relies on reference samples that pre-exist in any texture laboratory. •Experimentally and empirically corrected textures are in very good agreement.« less
Klitz, W; Maiers, M; Spellman, S; Baxter-Lowe, L A; Schmeckpeper, B; Williams, T M; Fernandez-Viña, M
2003-10-01
A collaborative study involving a large sample of European Americans was typed for the histocompatibility loci of the HLA DR-DQ region and subjected to intensive typing validation measures in order to accurately determine haplotype composition and frequency. The resulting tables have immediate application to HLA typing and allogeneic transplantation. The loci within the DR-DQ region are especially valuable for such an undertaking because of their tight linkage and high linkage disequilibrium. The 3798 haplotypes, derived from 1899 unrelated individuals, had a total of 75 distinct DRB1-DQA1-DQB1 haplotypes. The frequency distribution of the haplotypes was right skewed with haplotypes occurring at a frequency of less than 1% numbering 59 and yet constituting less than 12% of the total sample. Given DRB1 typing, it was possible to infer the exact DQA1 and DQB1 composition of a haplotype with high confidence (>90% likelihood) in 21 of the 35 high-resolution DRB1 alleles present in the sample. Of the DRB1 alleles without high reliability for DQ haplotype inference, only *0401, *0701 and *1302 were common, the remaining 11 DRB1 alleles constituting less than 5% of the total sample. This approach failed for the 13 serologically equivalent DR alleles in which only 33% of DQ haplotypes could be reliably inferred. The 36 DQA1-DQB1 haplotypes present in the total sample conformed to the known pattern of permissible heterodimers. Four DQA1-DQB1 haplotypes, all rare, are reported here for the first time. The haplotype frequency tables are suitable as a reference standard for HLA typing of the DR and DQ loci in European Americans.
Methods for the field evaluation of quantitative G6PD diagnostics: a review.
Ley, Benedikt; Bancone, Germana; von Seidlein, Lorenz; Thriemer, Kamala; Richards, Jack S; Domingo, Gonzalo J; Price, Ric N
2017-09-11
Individuals with glucose-6-phosphate dehydrogenase (G6PD) deficiency are at risk of severe haemolysis following the administration of 8-aminoquinoline compounds. Primaquine is the only widely available 8-aminoquinoline for the radical cure of Plasmodium vivax. Tafenoquine is under development with the potential to simplify treatment regimens, but point-of-care (PoC) tests will be needed to provide quantitative measurement of G6PD activity prior to its administration. There is currently a lack of appropriate G6PD PoC tests, but a number of new tests are in development and are likely to enter the market in the coming years. As these are implemented, they will need to be validated in field studies. This article outlines the technical details for the field evaluation of novel quantitative G6PD diagnostics such as sample handling, reference testing and statistical analysis. Field evaluation is based on the comparison of paired samples, including one sample tested by the new assay at point of care and one sample tested by the gold-standard reference method, UV spectrophotometry in an established laboratory. Samples can be collected as capillary or venous blood; the existing literature suggests that potential differences in capillary or venous blood are unlikely to affect results substantially. The collection and storage of samples is critical to ensure preservation of enzyme activity, it is recommended that samples are stored at 4 °C and testing occurs within 4 days of collection. Test results can be visually presented as scatter plot, Bland-Altman plot, and a histogram of the G6PD activity distribution of the study population. Calculating the adjusted male median allows categorizing results according to G6PD activity to calculate standard performance indicators and to perform receiver operating characteristic (ROC) analysis.
Aguirre-Gutiérrez, Jesús; Carvalheiro, Luísa G; Polce, Chiara; van Loon, E Emiel; Raes, Niels; Reemer, Menno; Biesmeijer, Jacobus C
2013-01-01
Understanding species distributions and the factors limiting them is an important topic in ecology and conservation, including in nature reserve selection and predicting climate change impacts. While Species Distribution Models (SDM) are the main tool used for these purposes, choosing the best SDM algorithm is not straightforward as these are plentiful and can be applied in many different ways. SDM are used mainly to gain insight in 1) overall species distributions, 2) their past-present-future probability of occurrence and/or 3) to understand their ecological niche limits (also referred to as ecological niche modelling). The fact that these three aims may require different models and outputs is, however, rarely considered and has not been evaluated consistently. Here we use data from a systematically sampled set of species occurrences to specifically test the performance of Species Distribution Models across several commonly used algorithms. Species range in distribution patterns from rare to common and from local to widespread. We compare overall model fit (representing species distribution), the accuracy of the predictions at multiple spatial scales, and the consistency in selection of environmental correlations all across multiple modelling runs. As expected, the choice of modelling algorithm determines model outcome. However, model quality depends not only on the algorithm, but also on the measure of model fit used and the scale at which it is used. Although model fit was higher for the consensus approach and Maxent, Maxent and GAM models were more consistent in estimating local occurrence, while RF and GBM showed higher consistency in environmental variables selection. Model outcomes diverged more for narrowly distributed species than for widespread species. We suggest that matching study aims with modelling approach is essential in Species Distribution Models, and provide suggestions how to do this for different modelling aims and species' data characteristics (i.e. sample size, spatial distribution).
Tsai, Pei-Chien; Breen, Matthew
2012-09-01
To identify suitable reference genes for normalization of real-time quantitative PCR (RT-qPCR) assay data for common tumors of dogs. Malignant lymph node (n = 8), appendicular osteosarcoma (9), and histiocytic sarcoma (12) samples and control samples of various nonneoplastic canine tissues. Array-based comparative genomic hybridization (aCGH) data were used to guide selection of 9 candidate reference genes. Expression stability of candidate reference genes and 4 commonly used reference genes was determined for tumor samples with RT-qPCR assays and 3 software programs. LOC611555 was the candidate reference gene with the highest expression stability among the 3 tumor types. Of the commonly used reference genes, expression stability of HPRT was high in histiocytic sarcoma samples, and expression stability of Ubi and RPL32 was high in osteosarcoma samples. Some of the candidate reference genes had higher expression stability than did the commonly used reference genes. Data for constitutively expressed genes with high expression stability are required for normalization of RT-qPCR assay results. Without such data, accurate quantification of gene expression in tumor tissue samples is difficult. Results of the present study indicated LOC611555 may be a useful RT-qPCR assay reference gene for multiple tissue types. Some commonly used reference genes may be suitable for normalization of gene expression data for tumors of dogs, such as lymphomas, osteosarcomas, or histiocytic sarcomas.
Enhanced conformational sampling using enveloping distribution sampling.
Lin, Zhixiong; van Gunsteren, Wilfred F
2013-10-14
To lessen the problem of insufficient conformational sampling in biomolecular simulations is still a major challenge in computational biochemistry. In this article, an application of the method of enveloping distribution sampling (EDS) is proposed that addresses this challenge and its sampling efficiency is demonstrated in simulations of a hexa-β-peptide whose conformational equilibrium encompasses two different helical folds, i.e., a right-handed 2.7(10∕12)-helix and a left-handed 3(14)-helix, separated by a high energy barrier. Standard MD simulations of this peptide using the GROMOS 53A6 force field did not reach convergence of the free enthalpy difference between the two helices even after 500 ns of simulation time. The use of soft-core non-bonded interactions in the centre of the peptide did enhance the number of transitions between the helices, but at the same time led to neglect of relevant helical configurations. In the simulations of a two-state EDS reference Hamiltonian that envelops both the physical peptide and the soft-core peptide, sampling of the conformational space of the physical peptide ensures that physically relevant conformations can be visited, and sampling of the conformational space of the soft-core peptide helps to enhance the transitions between the two helices. The EDS simulations sampled many more transitions between the two helices and showed much faster convergence of the relative free enthalpy of the two helices compared with the standard MD simulations with only a slightly larger computational effort to determine optimized EDS parameters. Combined with various methods to smoothen the potential energy surface, the proposed EDS application will be a powerful technique to enhance the sampling efficiency in biomolecular simulations.
Development of new reference material neohesperidin for quality control of dietary supplements.
Gong, Ningbo; Zhang, Baoxi; Yang, Dezhi; Gao, Zhaolin; Du, Guanhua; Lu, Yang
2015-07-01
Neohesperidin is an important natural flavanone glycoside distributed in several citrus species. This compound is widely used as a raw material for food additives in the food industry. The request for certified reference materials (CRMs) in dietary supplements was stipulated by the National Administrative Committee for CRMs and was underpinned by the need to improve the accuracy and comparability of measurement data and to establish metrological traceability of analytical results. This paper reports the sample preparation methodology, homogeneity and stability studies, value assignment and uncertainty estimation of a new certified reference material of neohesperidin (GBW09522). Differential scanning calorimetry, coulometric titration and mass balance methods proved to be sufficiently reliable and accurate for certification purposes. The certified value of neohesperidin CRM is 994 g kg(-1) with an expanded uncertainty of 4 g kg(-1) (k = 2). The reference material described above was homogeneous and stable for 12 months at a storage temperature of 25 °C. The new CRM of neohesperidin can be used to validate analytical methods and improve the accuracy of measurement data as well as quality control of neohesperidin-related dietary supplements, foods, traditional herbs and pharmaceutical formulations. © 2014 Society of Chemical Industry.
Lind, Emma E; Grahn, Mats
2011-05-01
Contamination can cause a rapid environmental change which may require populations to respond with evolutionary changes. To evaluate the effects of pulp mill effluents on population genetics, we sampled three-spined sticklebacks (Gasterosteus aculeatus) near four pulp mills and four adjacent reference sites and analyzed Amplified Fragment Length Polymorphism (AFLP) to compare genetic variability. A fine scale genetic structure was detected and samples from polluted sites separated from reference sites in multidimensional scaling plots (P<0.005, 1000 permutations) and locus-by-locus Analysis of Molecular Variance (AMOVA) further confirmed that habitats are significantly separated (F(ST)=0.021, P<0.01, 1023 permutations). The amount of genetic variation between populations did not differ between habitats, and populations from both habitats had similar levels of heterozygosity (polluted sites Nei's Hs=0.11, reference sites Nei's Hs=0.11). Still, pairwise F(ST): s between three, out of four, pairs of polluted-reference sites were significant. A F(ST)-outlier analysis showed that 21 (8.4%) loci were statistically different from a neutral distribution at the P<0.05 level and therefore indicated to be under divergent selection. When removing 13 F(ST)-outlier loci, significant at the P<0.01 level, differentiation between habitats disappeared in a multidimensional scaling plot. In conclusion, pulp mill effluence has acted as a selective agent on natural populations of G. aculeatus, causing a convergence in genotype composition change at multiple sites in an open environment. © The Author(s) 2011. This article is published with open access at Springerlink.com
Trap-Nesting Hymenoptera and Their Network with Parasites in Recovered Riparian Forests Brazil.
Araujo, G J; Fagundes, R; Antonini, Y
2018-02-01
Different aspects of human activities can cause environmental change that endanger species persistence, alter species distributions, and lead to changes in antagonistic and mutualistic interactions, whereas deforestation and flooding of riparian forest results in landscapes consisting of patchily distributed riparian forest fragments in a matrix of pastures, plantations, and urban areas. Therefore, we assessed the richness, abundance, and trophic interactions of trap-nesting Hymenoptera and their parasites at four patches of restored riparian forest and at one reference natural fragment, of different sizes and ages, located at the Volta Grande Reservoir, in Minas Gerais and São Paulo states to answer the following questions: (1) Does the richness and abundance of cavity-nesting bees and wasps differ in riparian forest fragments according to the seasonal periods? (2) Does the composition of cavity-nesting bees and wasps vary among restoration and reference sites and between climate seasons (wet and dry)? (3) How do the degrees of specialization of the parasites vary among the patches of forest? We recorded 12 species of wasps, eight of bees, and nine species of parasites. Areas with longer time since restoration (reference site) showed higher species richness. However, the abundance was higher in most recent areas. The composition of bee and wasp assembly has not significantly changed between the climate seasons, although it is different between sampling areas. The richness and abundance were higher in warmer and rainy periods. The rate of bee and wasp mortality was high. The degree of specialization of parasites varies among sampling units, and the network of host-parasite interaction has a modular configuration with generalists and specialists. We concluded that the restored areas with more complex habitat could provide better conditions for the reestablishment of ecological interactions among these insects, the local flora, and other invertebrates, which together contribute to the success of the restored environments.
Jiménez-Ballesta, R; García-Navarro, F J; Bravo, S; Amorós, J A; Pérez-de-Los-Reyes, C; Mejías, M
2017-10-01
Contamination of aquatic systems with potentially toxic trace elements (PTEs) is a major problem throughout the world. The National Park Tablas de Daimiel (NPTD) is considered to make up one of the two most important wetlands in the Biosphere Reserve called "Wet Spot." Since PTEs are good indicator of the prevailing environmental conditions and possible contamination, soil samples collected from 43 sites were analyzed in order to investigate the levels and its distribution of these elements, in the inundated floodplain area of the NPTD wetland. In addition, some physicochemical parameters such as pH, electrical conductivity and organic matter were measured. The total concentrations of 32 trace elements were determined by X-ray fluorescence. The results show that there was accumulation of lead (Pb), tin (Sn), selenium (Se), antimony (Sb), copper (Cu), vanadium (V), nickel (Ni), zinc (Zn), arsenic (As), strontium (Sr) and zirconium (Zr)-in some cases at high concentrations. The interpolated maps showed that the distributions of some of these elements and in some cases the trend in spatial variability are pronounced and decrease from the inlet to the outlet. The values for some elements are higher than the reference values, which is consistent with contamination (some values are higher by a factor of more than 10 compared to the reference). In the case of iodine (I), the levels at some sample points are significantly more than ten times the reference; Se appears in the range from 1.0 to 9.8 mg/kg, with an average value of 3.1 mg/kg, and these can be considered as seleniferous soils. The concentrations found are consistent with the introduction in the wetland of pollution by human activities, such as agricultural non-point sources, uncontrolled fertilization over many years, treatment with urban wastewater and other possible sources.
Barrett, H E; Cunnane, E M; O Brien, J M; Moloney, M A; Kavanagh, E G; Walsh, M T
2017-10-01
The purpose of this study is to determine the optimal target CT spatial resolution for accurately imaging abdominal aortic aneurysm (AAA) wall characteristics, distinguishing between tissue and calcification components, for an accurate assessment of rupture risk. Ruptured and non-ruptured AAA-wall samples were acquired from eight patients undergoing open surgical aneurysm repair upon institutional review board approval and informed consent was obtained from all patients. Physical measurements of AAA-wall cross-section were made using scanning electron microscopy. Samples were scanned using high resolution micro-CT scanning. A resolution range of 15.5-155μm was used to quantify the influence of decreasing resolution on wall area measurements, in terms of tissue and calcification. A statistical comparison between the reference resolution (15.5μm) and multi-detector CT resolution (744μm) was also made. Electron microscopy examination of ruptured AAAs revealed extremely thin outer tissue structure <200μm in radial distribution which is supporting the aneurysm wall along with large areas of adjacent medial calcifications far greater in area than the tissue layer. The spatial resolution of 155μm is a significant predictor of the reference AAA-wall tissue and calcification area measurements (r=0.850; p<0.001; r=0.999; p<0.001 respectively). The tissue and calcification area at 155μm is correct within 8.8%±1.86 and 26.13%±9.40 respectively with sensitivity of 87.17% when compared to the reference. The inclusion of AAA-wall measurements, through the use of high resolution-CT will elucidate the variations in AAA-wall tissue and calcification distributions across the wall which may help to leverage an improved assessment of AAA rupture risk. Copyright © 2017 Elsevier B.V. All rights reserved.
Elbers, A R W; Gorgievski-Duijvesteijn, M J; van der Velden, P G; Loeffen, W L A
2007-05-01
Outbreaks of Classical Swine Fever (CSF) occurred in spring 2006 in Germany close to the Dutch border. On 6th April Dutch pig farmers were given the possibility to submit blood samples directly via their veterinary practitioner to the National Reference Laboratory for CSF if their pigs had non-specific clinical symptoms or if pigs were being treated with antibiotics. The pig farm was not quarantined and was not visited by the veterinary authorities. Over a period of 9 weeks 156 pig farmers submitted whole blood samples via 50 different veterinary practices. All samples tested negative in the PCR test. These pig farmers and veterinary practitioners were asked to respond to a postal questionnaire with questions regarding their experience with this new diagnostic possibility, the distribution of the costs involved, a comparison with other instruments, such as official notification or use of a leukocyte count test, and their knowledge of clinical signs of CSF. 65 pig farmers (42%) and 33 veterinary practices (66%) returned the questionnaire. The main results indicated that pig farmers (72%) would use this type of exclusion diagnostics sooner than that they would approach the veterinary authorities (practitioners: 86%). Moreover the respondents considered the fact that the farm was not quarantined immediately to be an advantage (pig farmers, 79%; practitioners, 88%). 32 percent of the pig farmers were not aware that they were required to submit blood samples if pigs were being treated with antibiotics (practitioners: 11%). The majority of pig farmers and practitioners were not satisfied with the current distribution of the costs involved: in their opinion the costs of the PCR test, the costs of the veterinary practitioner and the costs for shipping the samples to the reference laboratory should be paid out of the Animal Health Fund (50% government and 50% industry) or by the government. If the current distribution of the costs is not changed, a large proportion of the pig farmers indicated that they would not use this form of exclusion diagnostics for CSF in the future. Pig farmers appeared to have a rather limited knowledge of the clinical signs of CSF: 33% of the pig farmers could mention maximally three clinical signs of CSF, and 7% could not mention a single clinical sign of CSF and said they were entirely dependent on the practitioners' ability to judge a CSF-suspect situation.
Security of Distributed-Phase-Reference Quantum Key Distribution
NASA Astrophysics Data System (ADS)
Moroder, Tobias; Curty, Marcos; Lim, Charles Ci Wen; Thinh, Le Phuc; Zbinden, Hugo; Gisin, Nicolas
2012-12-01
Distributed-phase-reference quantum key distribution stands out for its easy implementation with present day technology. For many years, a full security proof of these schemes in a realistic setting has been elusive. We solve this long-standing problem and present a generic method to prove the security of such protocols against general attacks. To illustrate our result, we provide lower bounds on the key generation rate of a variant of the coherent-one-way quantum key distribution protocol. In contrast to standard predictions, it appears to scale quadratically with the system transmittance.
NASA Astrophysics Data System (ADS)
Atemkeng, M.; Smirnov, O.; Tasse, C.; Foster, G.; Keimpema, A.; Paragi, Z.; Jonas, J.
2018-07-01
Traditional radio interferometric correlators produce regular-gridded samples of the true uv-distribution by averaging the signal over constant, discrete time-frequency intervals. This regular sampling and averaging then translate to be irregular-gridded samples in the uv-space, and results in a baseline-length-dependent loss of amplitude and phase coherence, which is dependent on the distance from the image phase centre. The effect is often referred to as `decorrelation' in the uv-space, which is equivalent in the source domain to `smearing'. This work discusses and implements a regular-gridded sampling scheme in the uv-space (baseline-dependent sampling) and windowing that allow for data compression, field-of-interest shaping, and source suppression. The baseline-dependent sampling requires irregular-gridded sampling in the time-frequency space, i.e. the time-frequency interval becomes baseline dependent. Analytic models and simulations are used to show that decorrelation remains constant across all the baselines when applying baseline-dependent sampling and windowing. Simulations using MeerKAT telescope and the European Very Long Baseline Interferometry Network show that both data compression, field-of-interest shaping, and outer field-of-interest suppression are achieved.
NASA Astrophysics Data System (ADS)
Laloy, Eric; Linde, Niklas; Jacques, Diederik; Mariethoz, Grégoire
2016-04-01
The sequential geostatistical resampling (SGR) algorithm is a Markov chain Monte Carlo (MCMC) scheme for sampling from possibly non-Gaussian, complex spatially-distributed prior models such as geologic facies or categorical fields. In this work, we highlight the limits of standard SGR for posterior inference of high-dimensional categorical fields with realistically complex likelihood landscapes and benchmark a parallel tempering implementation (PT-SGR). Our proposed PT-SGR approach is demonstrated using synthetic (error corrupted) data from steady-state flow and transport experiments in categorical 7575- and 10,000-dimensional 2D conductivity fields. In both case studies, every SGR trial gets trapped in a local optima while PT-SGR maintains an higher diversity in the sampled model states. The advantage of PT-SGR is most apparent in an inverse transport problem where the posterior distribution is made bimodal by construction. PT-SGR then converges towards the appropriate data misfit much faster than SGR and partly recovers the two modes. In contrast, for the same computational resources SGR does not fit the data to the appropriate error level and hardly produces a locally optimal solution that looks visually similar to one of the two reference modes. Although PT-SGR clearly surpasses SGR in performance, our results also indicate that using a small number (16-24) of temperatures (and thus parallel cores) may not permit complete sampling of the posterior distribution by PT-SGR within a reasonable computational time (less than 1-2 weeks).
Adaptive sampling in research on risk-related behaviors.
Thompson, Steven K; Collins, Linda M
2002-11-01
This article introduces adaptive sampling designs to substance use researchers. Adaptive sampling is particularly useful when the population of interest is rare, unevenly distributed, hidden, or hard to reach. Examples of such populations are injection drug users, individuals at high risk for HIV/AIDS, and young adolescents who are nicotine dependent. In conventional sampling, the sampling design is based entirely on a priori information, and is fixed before the study begins. By contrast, in adaptive sampling, the sampling design adapts based on observations made during the survey; for example, drug users may be asked to refer other drug users to the researcher. In the present article several adaptive sampling designs are discussed. Link-tracing designs such as snowball sampling, random walk methods, and network sampling are described, along with adaptive allocation and adaptive cluster sampling. It is stressed that special estimation procedures taking the sampling design into account are needed when adaptive sampling has been used. These procedures yield estimates that are considerably better than conventional estimates. For rare and clustered populations adaptive designs can give substantial gains in efficiency over conventional designs, and for hidden populations link-tracing and other adaptive procedures may provide the only practical way to obtain a sample large enough for the study objectives.
Wickham, J.D.; Stehman, S.V.; Smith, J.H.; Wade, T.G.; Yang, L.
2004-01-01
Two-stage cluster sampling reduces the cost of collecting accuracy assessment reference data by constraining sample elements to fall within a limited number of geographic domains (clusters). However, because classification error is typically positively spatially correlated, within-cluster correlation may reduce the precision of the accuracy estimates. The detailed population information to quantify a priori the effect of within-cluster correlation on precision is typically unavailable. Consequently, a convenient, practical approach to evaluate the likely performance of a two-stage cluster sample is needed. We describe such an a priori evaluation protocol focusing on the spatial distribution of the sample by land-cover class across different cluster sizes and costs of different sampling options, including options not imposing clustering. This protocol also assesses the two-stage design's adequacy for estimating the precision of accuracy estimates for rare land-cover classes. We illustrate the approach using two large-area, regional accuracy assessments from the National Land-Cover Data (NLCD), and describe how the a priorievaluation was used as a decision-making tool when implementing the NLCD design.
Menke, Andy; Rust, Keith F; Savage, Peter J; Cowie, Catherine C
2014-02-01
Although mean concentrations of hemoglobin A1c (A1C), fasting plasma glucose, and 2-hour plasma glucose differ by demographics, it is unclear what other characteristics of the distributions may differ, such as the amount of asymmetry of the distribution (skewness) and shift left or right compared with another distribution (shift). Using kernel density estimation, we created smoothed plots of the distributions of fasting plasma glucose (N = 7250), 2-hour plasma glucose (N = 5851), and A1C (N = 16,209) by age, race-ethnicity, and sex in the 2005-2010 National Health and Nutrition Examination Survey, a nationally representative sample of U.S. adults including people with and without diabetes. We tested differences in distributions using cumulative logistic regression. The distributions were generally unimodal and right-skewed. All distributions were shifted higher and more right-skewed for older age groups (P < .001 for each marker). Compared with non-Hispanic whites, the distribution of fasting plasma glucose was shifted higher for Mexican-Americans (P = .01), whereas the distribution of A1C was shifted higher for non-Hispanic blacks (P < .001). The distribution of fasting plasma glucose was shifted higher for men (P < .001) and the distribution of 2-hour plasma glucose was shifted higher for women (P = .01). We provide a graphic reference for comparing these distributions and diabetes cut-points by demographic factors. Copyright © 2014 Elsevier Inc. All rights reserved.
Evaluations of lunar regolith simulants
NASA Astrophysics Data System (ADS)
Taylor, Lawrence A.; Pieters, Carle M.; Britt, Daniel
2016-07-01
Apollo lunar regolith samples are not available in quantity for engineering studies with In-Situ Resource Utilization (ISRU). Therefore, with expectation of a return to the Moon, dozens of regolith (soil) simulants have been developed, to some extent a result of inefficient distribution of NASA-sanctioned simulants. In this paper, we review many of these simulants, with evaluations of their short-comings. In 2010, the NAC-PSS committee instructed the Lunar Exploration Advisory Group (LEAG) and CAPTEM (the NASA committee recommending on the appropriations of Apollo samples) to report on the status of lunar regolith simulants. This report is reviewed here-in, along with a list of the plethora of lunar regolith simulants and references. In addition, and importantly, a special, unique Apollo 17 soil sample (70050) discussed, which has many of the properties sought for ISRU studies, should be available in reasonable amounts for ISRU studies.
NASA Astrophysics Data System (ADS)
Ravisankar, R.; Manikandan, E.; Dheenathayalu, M.; Rao, Brahmaji; Seshadreesan, N. P.; Nair, K. G. M.
2006-10-01
Beach rocks are a peculiar type of formation when compared to other types of rocks. Rare earth element (REE) concentrations in beach rock samples collected from the South East Coast of Tamilnadu, India, have been measured using the instrumental neutron activation analysis (INAA) single comparator K0 method. The irradiations were carried out using a thermal neutron flux of ˜10 11 n cm -2 s -1 at 20 kW power using the Kalpakkam mini reactor (KAMINI), IGCAR, Kalpakkam, Tamilnadu. Accuracy and precision were evaluated by assaying irradiated standard reference material (SRM 1646a estuarine sediment). The results being found to be in good agreement with certified values. REE elements have been determined from 15 samples using high-resolution gamma spectrometry. The geochemical behavior of REE in beach rock, in particular REE (chondrite-normalized) pattern has been studied.
Rosero, Eric B; Peshock, Ronald M; Khera, Amit; Clagett, Patrick; Lo, Hao; Timaran, Carlos H
2011-04-01
Reference values and age-related changes of the wall thickness of the abdominal aorta have not been described in the general population. We characterized age-, race-, and gender-specific distributions, and yearly rates of change of mean aortic wall thickness (MAWT), and associations between MAWT and cardiovascular risk factors in a multi-ethnic population-based probability sample. Magnetic resonance imaging measurements of MAWT were performed on 2466 free-living white, black, and Hispanic adult subjects. MAWT race/ethnicity- and gender-specific percentile values across age were estimated using regression analyses. MAWT was greater in men than in women and increased linearly with age in all the groups and across all the percentiles. Hispanic women had the thinnest and black men the thickest aortas. Black men had the highest and white women the lowest age-related MAWT increase. Age, gender, ethnicity, smoking status, systolic blood pressure, low-density lipoprotein-cholesterol levels, high-density lipoprotein-cholesterol levels, and fasting glucose levels were independent predictors of MAWT. Age, gender, and racial/ethnic differences in MAWT distributions exist in the general population. Such differences should be considered in future investigations assessing aortic atherosclerosis and the effects of anti-atherosclerotic therapies. Published by Mosby, Inc.
[Geographical distribution of the Serum creatinine reference values of healthy adults].
Wei, De-Zhi; Ge, Miao; Wang, Cong-Xia; Lin, Qian-Yi; Li, Meng-Jiao; Li, Peng
2016-11-20
To explore the relationship between serum creatinine (Scr) reference values in healthy adults and geographic factors and provide evidence for establishing Scr reference values in different regions. We collected 29 697 Scr reference values from healthy adults measured by 347 medical facilities from 23 provinces, 4 municipalities and 5 autonomous regions. We chose 23 geographical factors and analyzed their correlation with Scr reference values to identify the factors correlated significantly with Scr reference values. According to the Principal component analysis and Ridge regression analysis, two predictive models were constructed and the optimal model was chosen after comparison of the two model's fitting degree of predicted results and measured results. The distribution map of Scr reference values was drawn using the Kriging interpolation method. Seven geographic factors, including latitude, annual sunshine duration, annual average temperature, annual average relative humidity, annual precipitation, annual temperature range and topsoil (silt) cation exchange capacity were found to correlate significantly with Scr reference values. The overall distribution of Scr reference values featured a pattern that the values were high in the south and low in the north, varying consistently with the latitude change. The data of the geographic factors in a given region allows the prediction of the Scr values in healthy adults. Analysis of these geographical factors can facilitate the determination of the reference values specific to a region to improve the accuracy for clinical diagnoses.
Mayer, René E; Reischer, Georg H; Ixenmaier, Simone K; Derx, Julia; Blaschke, Alfred Paul; Ebdon, James E; Linke, Rita; Egle, Lukas; Ahmed, Warish; Blanch, Anicet R; Byamukama, Denis; Savill, Marion; Mushi, Douglas; Cristóbal, Héctor A; Edge, Thomas A; Schade, Margit A; Aslan, Asli; Brooks, Yolanda M; Sommer, Regina; Masago, Yoshifumi; Sato, Maria I; Taylor, Huw D; Rose, Joan B; Wuertz, Stefan; Shanks, Orin C; Piringer, Harald; Mach, Robert L; Savio, Domenico; Zessner, Matthias; Farnleitner, Andreas H
2018-05-01
Numerous bacterial genetic markers are available for the molecular detection of human sources of fecal pollution in environmental waters. However, widespread application is hindered by a lack of knowledge regarding geographical stability, limiting implementation to a small number of well-characterized regions. This study investigates the geographic distribution of five human-associated genetic markers (HF183/BFDrev, HF183/BacR287, BacHum-UCD, BacH, and Lachno2) in municipal wastewaters (raw and treated) from 29 urban and rural wastewater treatment plants (750-4 400 000 population equivalents) from 13 countries spanning six continents. In addition, genetic markers were tested against 280 human and nonhuman fecal samples from domesticated, agricultural and wild animal sources. Findings revealed that all genetic markers are present in consistently high concentrations in raw (median log 10 7.2-8.0 marker equivalents (ME) 100 mL -1 ) and biologically treated wastewater samples (median log 10 4.6-6.0 ME 100 mL -1 ) regardless of location and population. The false positive rates of the various markers in nonhuman fecal samples ranged from 5% to 47%. Results suggest that several genetic markers have considerable potential for measuring human-associated contamination in polluted environmental waters. This will be helpful in water quality monitoring, pollution modeling and health risk assessment (as demonstrated by QMRAcatch) to guide target-oriented water safety management across the globe.
NASA Astrophysics Data System (ADS)
Netzeband, Christian; Arlt, Tobias; Wippermann, Klaus; Lehnert, Werner; Manke, Ingo
2016-09-01
This study investigates the ageing effects on the microstructure of the anode catalyst layer of direct methanol fuel cells (DMFC) after complete methanol starvation. To this end the samples of two methanol-depleted membrane electrode assemblies (MEA) have been compared with a pristine reference sample. A three-dimensional characterization of the anode catalyst layer (ACL) structure on a nanometer scale has been conducted by focused ion beam (FIB)/scanning electron microscope (SEM) tomography. The FIB/SEM tomography allows for a detailed analysis of statistic parameters of micro-structured materials, such as porosity, tortuosity and pore size distributions. Furthermore, the SEM images displayed a high material contrast between the heavy catalyst metals (Pt/Ru) and the relatively light carbon support, which made it possible to map the catalyst distribution in the acquired FIB/SEM tomographies. Additional synchrotron X-ray tomographies have been conducted in order to obtain an overview of the structural changes of all the components of a section of the MEAs after methanol depletion.
LaHaye, N. L.; Harilal, S. S.; Diwakar, P. K.; Hassanein, A.; Kulkarni, P.
2015-01-01
We investigated the role of femtosecond (fs) laser wavelength on laser ablation (LA) and its relation to laser generated aerosol counts and particle distribution, inductively coupled plasma-mass spectrometry (ICP-MS) signal intensity, detection limits, and elemental fractionation. Four different NIST standard reference materials (610, 613, 615, and 616) were ablated using 400 nm and 800 nm fs laser pulses to study the effect of wavelength on laser ablation rate, accuracy, precision, and fractionation. Our results show that the detection limits are lower for 400 nm laser excitation than 800 nm laser excitation at lower laser energies but approximately equal at higher energies. Ablation threshold was also found to be lower for 400 nm than 800 nm laser excitation. Particle size distributions are very similar for 400 nm and 800 nm wavelengths; however, they differ significantly in counts at similar laser fluence levels. This study concludes that 400 nm LA is more beneficial for sample introduction in ICP-MS, particularly when lower laser energies are to be used for ablation. PMID:26640294
Spatial and temporal distribution of benthic macroinvertebrates in a Southeastern Brazilian river.
Silveira, M P; Buss, D F; Nessimian, J L; Baptista, D F
2006-05-01
Benthic macroinvertebrate assemblages are structured according to physical and chemical parameters that define microhabitats, including food supply, shelter to escape predators, and other biological parameters that influence reproductive success. The aim of this study is to investigate spatial and temporal distribution of macroinvertebrate assemblages at the Macaé river basin, in Rio de Janeiro state, Southeastern Brazil. According to the "Habitat Assessment Field Data Sheet--High Gradient Streams" (Barbour et al., 1999), the five sampling sites are considered as a reference condition. Despite the differences in hydrological parameters (mean width, depth and discharge) among sites, the physicochemical parameters and functional feeding groups' general structure were similar, except for the less impacted area, which showed more shredders. According to the Detrended Correspondence Analysis based on substrates, there is a clear distinction between pool and riffle assemblages. In fact, the riffle litter substrate had higher taxa in terms of richness and abundance, but the pool litter substrate had the greatest number of exclusive taxa. A Cluster Analysis based on sampling sites data showed that temporal variation was the main factor in structuring macroinvertebrate assemblages in the studied habitats.
Li, Longhai; Feng, Cindy X; Qiu, Shi
2017-06-30
An important statistical task in disease mapping problems is to identify divergent regions with unusually high or low risk of disease. Leave-one-out cross-validatory (LOOCV) model assessment is the gold standard for estimating predictive p-values that can flag such divergent regions. However, actual LOOCV is time-consuming because one needs to rerun a Markov chain Monte Carlo analysis for each posterior distribution in which an observation is held out as a test case. This paper introduces a new method, called integrated importance sampling (iIS), for estimating LOOCV predictive p-values with only Markov chain samples drawn from the posterior based on a full data set. The key step in iIS is that we integrate away the latent variables associated the test observation with respect to their conditional distribution without reference to the actual observation. By following the general theory for importance sampling, the formula used by iIS can be proved to be equivalent to the LOOCV predictive p-value. We compare iIS and other three existing methods in the literature with two disease mapping datasets. Our empirical results show that the predictive p-values estimated with iIS are almost identical to the predictive p-values estimated with actual LOOCV and outperform those given by the existing three methods, namely, the posterior predictive checking, the ordinary importance sampling, and the ghosting method by Marshall and Spiegelhalter (2003). Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.
NASA Astrophysics Data System (ADS)
Milliere, L.; Maskasheva, K.; Laurent, C.; Despax, B.; Boudou, L.; Teyssedre, G.
2016-01-01
The aim of this work is to limit charge injection from a semi-conducting electrode into low density polyethylene (LDPE) under dc field by tailoring the polymer surface using a silver nanoparticles-containing layer. The layer is composed of a plane of silver nanoparticles embedded in a semi-insulating organosilicon matrix deposited on the polyethylene surface by a plasma process. Size, density and surface coverage of the nanoparticles are controlled through the plasma process. Space charge distribution in 300 μm thick LDPE samples is measured by the pulsed-electroacoustic technique following a short term (step-wise voltage increase up to 50 kV mm-1, 20 min in duration each, followed by a polarity inversion) and a longer term (up to 12 h under 40 kV mm-1) protocols for voltage application. A comparative study of space charge distribution between a reference polyethylene sample and the tailored samples is presented. It is shown that the barrier effect depends on the size distribution and the surface area covered by the nanoparticles: 15 nm (average size) silver nanoparticles with a high surface density but still not percolating form an efficient barrier layer that suppress charge injection. It is worthy to note that charge injection is detected for samples tailored with (i) percolating nanoparticles embedded in organosilicon layer; (ii) with organosilicon layer only, without nanoparticles and (iii) with smaller size silver particles (<10 nm) embedded in organosilicon layer. The amount of injected charges in the tailored samples increases gradually in the samples ranking given above. The mechanism of charge injection mitigation is discussed on the basis of complementary experiments carried out on the nanocomposite layer such as surface potential measurements. The ability of silver clusters to stabilize electrical charges close to the electrode thereby counterbalancing the applied field appears to be a key factor in explaining the charge injection mitigation effect.
Estimating Transmitted-Signal Phase Variations for Uplink Array Antennas
NASA Technical Reports Server (NTRS)
Paal, Leslie; Mukai, Ryan; Vilntrotter, Victor; Cornish, Timothy; Lee, Dennis
2009-01-01
A method of estimating phase drifts of microwave signals distributed to, and transmitted by, antennas in an array involves the use of the signals themselves as phase references. The method was conceived as part of the solution of the problem of maintaining precise phase calibration required for proper operation of an array of Deep Space Network (DSN) antennas on Earth used for communicating with distant spacecraft at frequencies between 7 and 8 GHz. The method could also be applied to purely terrestrial phased-array radar and other radio antenna array systems. In the DSN application, the electrical lengths (effective signal-propagation path lengths) of the various branches of the system for distributing the transmitted signals to the antennas are not precisely known, and they vary with time. The variations are attributable mostly to thermal expansion and contraction of fiber-optic and electrical signal cables and to a variety of causes associated with aging of signal-handling components. The variations are large enough to introduce large phase drifts at the signal frequency. It is necessary to measure and correct for these phase drifts in order to maintain phase calibration of the antennas. A prior method of measuring phase drifts involves the use of reference-frequency signals separate from the transmitted signals. A major impediment to accurate measurement of phase drifts over time by the prior method is the fact that although DSN reference-frequency sources separate from the transmitting signal sources are stable and accurate enough for most DSN purposes, they are not stable enough for use in maintaining phase calibrations, as required, to within a few degrees over times as long as days or possibly even weeks. By eliminating reliance on the reference-frequency subsystem, the present method overcomes this impediment. In a DSN array to which the present method applies (see figure), the microwave signals to be transmitted are generated by exciters in a signal-processing center, then distributed to the antennas via optical fibers. At each antenna, the signals are used to drive a microwave power-amplifier train, the output of which is coupled to the antenna for transmission. A small fraction of the power-amplifier-train output is sent back to the signal-processing center along another optical fiber that is part of the same fiber-optic cable used to distribute the transmitted signal to the antenna. In the signal-processing center, the signal thus returned from each antenna is detected and its phase is compared with the phase of the signal sampled directly from the corresponding exciter. It is known, from other measurements, that the signal-propagation path length from the power-amplifier-train output port to the phase center of each antenna is sufficiently stable and, hence, that sampling the signal at the power-amplifier-train output port suffices for the purpose of characterizing the phase drift of the transmitted signal at the phase center of the antenna
Mucosal and Cutaneous Human Papillomaviruses Detected in Raw Sewages
La Rosa, Giuseppina; Fratini, Marta; Accardi, Luisa; D'Oro, Graziana; Della Libera, Simonetta; Muscillo, Michele; Di Bonito, Paola
2013-01-01
Epitheliotropic viruses can find their way into sewage. The aim of the present study was to investigate the occurrence, distribution, and genetic diversity of Human Papillomaviruses (HPVs) in urban wastewaters. Sewage samples were collected from treatment plants distributed throughout Italy. The DNA extracted from these samples was analyzed by PCR using five PV-specific sets of primers targeting the L1 (GP5/GP6, MY09/MY11, FAP59/64, SKF/SKR) and E1 regions (PM-A/PM-B), according to the protocols previously validated for the detection of mucosal and cutaneous HPV genotypes. PCR products underwent sequencing analysis and the sequences were aligned to reference genomes from the Papillomavirus Episteme database. Phylogenetic analysis was then performed to assess the genetic relationships among the different sequences and between the sequences of the samples and those of the prototype strains. A broad spectrum of sequences related to mucosal and cutaneous HPV types was detected in 81% of the sewage samples analyzed. Surprisingly, sequences related to the anogenital HPV6 and 11 were detected in 19% of the samples, and sequences related to the “high risk” oncogenic HPV16 were identified in two samples. Sequences related to HPV9, HPV20, HPV25, HPV76, HPV80, HPV104, HPV110, HPV111, HPV120 and HPV145 beta Papillomaviruses were detected in 76% of the samples. In addition, similarity searches and phylogenetic analysis of some sequences suggest that they could belong to putative new genotypes of the beta genus. In this study, for the first time, the presence of HPV viruses strongly related to human cancer is reported in sewage samples. Our data increases the knowledge of HPV genomic diversity and suggests that virological analysis of urban sewage can provide key information useful in supporting epidemiological studies. PMID:23341898
High resolution Fourier interferometer-spectrophotopolarimeter
NASA Technical Reports Server (NTRS)
Fymat, A. L. (Inventor)
1976-01-01
A high-resolution Fourier interferometer-spectrophotopolarimeter is provided using a single linear polarizer-analyzer the transmission axis azimuth of which is positioned successively in the three orientations of 0 deg, 45 deg, and 90 deg, in front of a detector; four flat mirrors, three of which are switchable to either of two positions to direct an incoming beam from an interferometer to the polarizer-analyzer around a sample cell transmitted through a medium in a cell and reflected by medium in the cell; and four fixed focussing lenses, all located in a sample chamber attached at the exit side of the interferometer. This arrangement can provide the distribution of energy and complete polarization state across the spectrum of the reference light entering from the interferometer; the same light after a fixed-angle reflection from the sample cell containing a medium to be analyzed; and the same light after direct transmission through the same sample cell, with the spectral resolution provided by the interferometer.
Effects of Simple Leaching of Crushed and Powdered Materials on High-precision Pb Isotope Analyses
NASA Astrophysics Data System (ADS)
Todd, E.; Stracke, A.
2013-12-01
We present new results of simple leaching experiments on the Pb isotope composition of USGS standard reference material powders and on ocean island basalt whole rock splits and powders. Rock samples were leached with 6N HCl in two steps, first hot and then in an ultrasonic bath, and washed with ultrapure H2O before conventional sample digestion and chromatographic purification of Pb. Pb isotope analyses were determined with Tl-doped MC-ICP-MS. Intra- and inter-session analytical reproducibility of repeated analyses of both synthetic Pb solutions and Pb from single digests of chemically processed natural samples were generally < 100 ppm (2 S.D.). The comparison of leached and unleached samples shows that leaching reliably removes variable amounts of different contaminants for different starting materials. For repeated digests of a single sample, the leached samples reproduce better than the unleached ones, showing that leaching effectively removes heterogeneously distributed extraneous Pb. However, the reproducibility of repeated digests of variably contaminated natural samples is up to an order of magnitude worse than the analytical reproducibility of ca. 100 ppm. More complex leaching methods (e.g., Nobre Silva et al., 2009) yield Pb isotope ratios within error of and with similar reproducibility to our method, showing that the simple leaching method is reliable. The remaining Pb isotope heterogeneity of natural samples, which typically exceeds 100 ppm, is thus attributed to inherent isotopic sample heterogeneity. Tl-doped MC-ICP-MS Pb ratio determination is therefore a sufficiently precise method for Pb isotope analyses in natural rocks. More precise Pb double- or triple-spike methods (e.g., Galer, 1999; Thirlwall, 2000), may exploit their full potential only in cases where natural isotopic sample heterogeneity is demonstrably negligible. References: Galer, S., 1999, Chem. Geol. 157, 255-274. Nobre Silva, et al. 2009, Geochemistry Geophysics Geosystems 10, Q08012. Thirlwall, M.F., 2000, Chem. Geol. 163, 299-322.
KEY COMPARISON: Final report on CCQM-K69 key comparison: Testosterone glucuronide in human urine
NASA Astrophysics Data System (ADS)
Liu, Fong-Ha; Mackay, Lindsey; Murby, John
2010-01-01
The CCQM-K69 key comparison of testosterone glucuronide in human urine was organized under the auspices of the CCQM Organic Analysis Working Group (OAWG). The National Measurement Institute Australia (NMIA) acted as the coordinating laboratory for the comparison. The samples distributed for the key comparison were prepared at NMIA with funding from the World Anti-Doping Agency (WADA). WADA granted the approval for this material to be used for the intercomparison provided the distribution and handling of the material were strictly controlled. Three national metrology institutes (NMIs)/designated institutes (DIs) developed reference methods and submitted data for the key comparison along with two other laboratories who participated in the parallel pilot study. A good selection of analytical methods and sample workup procedures was displayed in the results submitted considering the complexities of the matrix involved. The comparability of measurement results was successfully demonstrated by the participating NMIs. Only the key comparison data were used to estimate the key comparison reference value (KCRV), using the arithmetic mean approach. The reported expanded uncertainties for results ranged from 3.7% to 6.7% at the 95% level of confidence and all results agreed within the expanded uncertainty of the KCRV. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).
Kane, J.S.
1991-01-01
A brief history of programs to develop geochemical reference samples and certified reference samples for use in geochemical analysis is presented. While progress has been made since G-1 and W-1 were issued, many challenges remain. ?? 1991.
Pertussis diagnosis in Belgium: results of the National Reference Centre for Bordetella anno 2015.
Martini, H; Rodeghiero, C; VAN DEN Poel, C; Vincent, M; Pierard, D; Huygen, K
2017-08-01
In 2015, the Belgian National Reference Centre for Bordetella analyzed 4110 respiratory samples by qPCR and 4877 serum samples by serology. Whereas about 50% of respiratory samples were from infants and children below the age of five, serum samples were distributed among all age categories. A total of 394 (9·6%) cases was diagnosed as positive for Bordetella pertussis by qPCR and 844 (17·3%) cases were diagnosed as acute infection by serology (anti-pertussis toxin (PT) IgG > 125 IU/ml). Another 1042 (21·4%) sera had anti-PT IgG between 55 and 125 IU/ml reflecting a vaccination or pertussis infection during the last 1-2 years. Seventy per cent of the pertussis cases diagnosed by qPRC were in infants and children younger than 14 years old, whereas the highest number of sera with anti-PT levels >125 IU/ml was in the age group of 10-14 years old. Based on the limited data of the last vaccination (reported for only 15% of the samples), recent booster vaccination in the teenager group may have contributed only minimally to these elevated anti-PT levels. The highest number of sera with anti-PT titers between 55 and 125 IU/ml was found in the age category 50-59 years old. It is clear that pertussis continues to be a problem in Belgium and that other vaccination strategies (maternal vaccination, cocoon vaccination) and ultimately better vaccines will be needed to control this highly infectious respiratory disease.
A Sorting Statistic with Application in Neurological Magnetic Resonance Imaging of Autism.
Levman, Jacob; Takahashi, Emi; Forgeron, Cynthia; MacDonald, Patrick; Stewart, Natalie; Lim, Ashley; Martel, Anne
2018-01-01
Effect size refers to the assessment of the extent of differences between two groups of samples on a single measurement. Assessing effect size in medical research is typically accomplished with Cohen's d statistic. Cohen's d statistic assumes that average values are good estimators of the position of a distribution of numbers and also assumes Gaussian (or bell-shaped) underlying data distributions. In this paper, we present an alternative evaluative statistic that can quantify differences between two data distributions in a manner that is similar to traditional effect size calculations; however, the proposed approach avoids making assumptions regarding the shape of the underlying data distribution. The proposed sorting statistic is compared with Cohen's d statistic and is demonstrated to be capable of identifying feature measurements of potential interest for which Cohen's d statistic implies the measurement would be of little use. This proposed sorting statistic has been evaluated on a large clinical autism dataset from Boston Children's Hospital , Harvard Medical School , demonstrating that it can potentially play a constructive role in future healthcare technologies.
A Sorting Statistic with Application in Neurological Magnetic Resonance Imaging of Autism
Takahashi, Emi; Lim, Ashley; Martel, Anne
2018-01-01
Effect size refers to the assessment of the extent of differences between two groups of samples on a single measurement. Assessing effect size in medical research is typically accomplished with Cohen's d statistic. Cohen's d statistic assumes that average values are good estimators of the position of a distribution of numbers and also assumes Gaussian (or bell-shaped) underlying data distributions. In this paper, we present an alternative evaluative statistic that can quantify differences between two data distributions in a manner that is similar to traditional effect size calculations; however, the proposed approach avoids making assumptions regarding the shape of the underlying data distribution. The proposed sorting statistic is compared with Cohen's d statistic and is demonstrated to be capable of identifying feature measurements of potential interest for which Cohen's d statistic implies the measurement would be of little use. This proposed sorting statistic has been evaluated on a large clinical autism dataset from Boston Children's Hospital, Harvard Medical School, demonstrating that it can potentially play a constructive role in future healthcare technologies. PMID:29796236
Wagner, Bjoern; Fischer, Holger; Kansy, Manfred; Seelig, Anna; Assmus, Frauke
2015-02-20
Here we present a miniaturized assay, referred to as Carrier-Mediated Distribution System (CAMDIS) for fast and reliable measurement of octanol/water distribution coefficients, log D(oct). By introducing a filter support for octanol, phase separation from water is facilitated and the tendency of emulsion formation (emulsification) at the interface is reduced. A guideline for the best practice of CAMDIS is given, describing a strategy to manage drug adsorption at the filter-supported octanol/buffer interface. We validated the assay on a set of 52 structurally diverse drugs with known shake flask log D(oct) values. Excellent agreement with literature data (r(2) = 0.996, standard error of estimate, SEE = 0.111), high reproducibility (standard deviation, SD < 0.1 log D(oct) units), minimal sample consumption (10 μL of 100 μM DMSO stock solution) and a broad analytical range (log D(oct) range = -0.5 to 4.2) make CAMDIS a valuable tool for the high-throughput assessment of log D(oc)t. Copyright © 2014 Elsevier B.V. All rights reserved.
Sample size determination for equivalence assessment with multiple endpoints.
Sun, Anna; Dong, Xiaoyu; Tsong, Yi
2014-01-01
Equivalence assessment between a reference and test treatment is often conducted by two one-sided tests (TOST). The corresponding power function and sample size determination can be derived from a joint distribution of the sample mean and sample variance. When an equivalence trial is designed with multiple endpoints, it often involves several sets of two one-sided tests. A naive approach for sample size determination in this case would select the largest sample size required for each endpoint. However, such a method ignores the correlation among endpoints. With the objective to reject all endpoints and when the endpoints are uncorrelated, the power function is the production of all power functions for individual endpoints. With correlated endpoints, the sample size and power should be adjusted for such a correlation. In this article, we propose the exact power function for the equivalence test with multiple endpoints adjusted for correlation under both crossover and parallel designs. We further discuss the differences in sample size for the naive method without and with correlation adjusted methods and illustrate with an in vivo bioequivalence crossover study with area under the curve (AUC) and maximum concentration (Cmax) as the two endpoints.
US Fish and Wildlife Service biomonitoring operations manual, Appendices A--K
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gianotto, D.F.; Rope, R.C.; Mondecar, M.
1993-04-01
Volume 2 contains Appendices and Summary Sheets for the following areas: A-Legislative Background and Key to Relevant Legislation, B- Biomonitoring Operations Workbook, C-Air Monitoring, D-Introduction to the Flora and Fauna for Biomonitoring, E-Decontamination Guidance Reference Field Methods, F-Documentation Guidance, Sample Handling, and Quality Assurance/Quality Control Standard Operating Procedures, G-Field Instrument Measurements Reference Field Methods, H-Ground Water Sampling Reference Field Methods, I-Sediment Sampling Reference Field Methods, J-Soil Sampling Reference Field Methods, K-Surface Water Reference Field Methods. Appendix B explains how to set up strategy to enter information on the ``disk workbook``. Appendix B is enhanced by DE97006389, an on-line workbook formore » users to be able to make revisions to their own biomonitoring data.« less
A time reference distribution concept for a time division communication network
NASA Technical Reports Server (NTRS)
Stover, H. A.
1973-01-01
Starting with an assumed ideal network having perfect clocks at every node and known fixed transmission delays between nodes, the effects of adding tolerances to both transmission delays and nodal clocks is described. The advantages of controlling tolerances on time rather than frequency are discussed. Then a concept is presented for maintaining these tolerances on time throughout the network. This concept, called time reference distribution, is a systematic technique for distributing time reference to all nodes of the network. It is reliable, survivable and possesses many other desirable characteristics. Some of its features such as an excellent self monitoring capability will be pointed out. Some preliminary estimates of the accuracy that might be expected are developed and there is a brief discussion of the impact upon communication system costs. Time reference distribution is a concept that appears very attractive. It has not had experimental evaluation and has not yet been endorsed for use in any communication network.
Impact of Image Noise on Gamma Index Calculation
NASA Astrophysics Data System (ADS)
Chen, M.; Mo, X.; Parnell, D.; Olivera, G.; Galmarini, D.; Lu, W.
2014-03-01
Purpose: The Gamma Index defines an asymmetric metric between the evaluated image and the reference image. It provides a quantitative comparison that can be used to indicate sample-wised pass/fail on the agreement of the two images. The Gamma passing/failing rate has become an important clinical evaluation tool. However, the presence of noise in the evaluated and/or reference images may change the Gamma Index, hence the passing/failing rate, and further, clinical decisions. In this work, we systematically studied the impact of the image noise on the Gamma Index calculation. Methods: We used both analytic formulation and numerical calculations in our study. The numerical calculations included simulations and clinical images. Three different noise scenarios were studied in simulations: noise in reference images only, in evaluated images only, and in both. Both white and spatially correlated noises of various magnitudes were simulated. For clinical images of various noise levels, the Gamma Index of measurement against calculation, calculation against measurement, and measurement against measurement, were evaluated. Results: Numerical calculations for both the simulation and clinical data agreed with the analytic formulations, and the clinical data agreed with the simulations. For the Gamma Index of measurement against calculation, its distribution has an increased mean and an increased standard deviation as the noise increases. On the contrary, for the Gamma index of calculation against measurement, its distribution has a decreased mean and stabilized standard deviation as the noise increases. White noise has greater impact on the Gamma Index than spatially correlated noise. Conclusions: The noise has significant impact on the Gamma Index calculation and the impact is asymmetric. The Gamma Index should be reported along with the noise levels in both reference and evaluated images. Reporting of the Gamma Index with switched roles of the images as reference and evaluated images or some composite metrics would be a good practice.
Cai, Y N; Pei, X T; Sun, P P; Xu, Y P; Liu, L; Ping, Z G
2018-06-10
Objective: To explore the characteristics of distribution on Chinese adult body mass index (BMI) in different age groups and genders and to provide reference related to obesity and related chronic diseases. Methods: Data from the China Health and Nutrition Survey in 2009 were used. Sequential sample cluster method was used to analyze the characteristics of BMI distribution in different age groups and genders by SAS. Results: Our results showed that the adult BMI in China should be divided into 3 groups according to their age, as 20 to 40 years old, 40 to 65 years old, and> 65 years old, in females or in total when grouped by difference of 5 years. For groupings in male, the three groups should be as 20 to 40, 40 to 60 years old and>60 years old. There were differences on distribution between the male and female groups. When grouped by difference of 10 years, all of the clusters for male, female and total groups as 20-40, 40-60 and>60 years old, became similar for the three classes, respectively, with no differences of distribution between gender, suggesting that the 5-years grouping was more accurate than the 10-years one, and BMI showing gender differences. Conclusions: BMI of the Chinese adults should be divided into 3 categories according to the characteristics of their age. Our results showed that BMI was increasing with age in youths and adolescents, remained unchanged in the middle-aged but decreasing in the elderly.
NASA Astrophysics Data System (ADS)
Mamalakis, Antonios; Langousis, Andreas; Deidda, Roberto; Marrocu, Marino
2017-03-01
Distribution mapping has been identified as the most efficient approach to bias-correct climate model rainfall, while reproducing its statistics at spatial and temporal resolutions suitable to run hydrologic models. Yet its implementation based on empirical distributions derived from control samples (referred to as nonparametric distribution mapping) makes the method's performance sensitive to sample length variations, the presence of outliers, the spatial resolution of climate model results, and may lead to biases, especially in extreme rainfall estimation. To address these shortcomings, we propose a methodology for simultaneous bias correction and high-resolution downscaling of climate model rainfall products that uses: (a) a two-component theoretical distribution model (i.e., a generalized Pareto (GP) model for rainfall intensities above a specified threshold u*, and an exponential model for lower rainrates), and (b) proper interpolation of the corresponding distribution parameters on a user-defined high-resolution grid, using kriging for uncertain data. We assess the performance of the suggested parametric approach relative to the nonparametric one, using daily raingauge measurements from a dense network in the island of Sardinia (Italy), and rainfall data from four GCM/RCM model chains of the ENSEMBLES project. The obtained results shed light on the competitive advantages of the parametric approach, which is proved more accurate and considerably less sensitive to the characteristics of the calibration period, independent of the GCM/RCM combination used. This is especially the case for extreme rainfall estimation, where the GP assumption allows for more accurate and robust estimates, also beyond the range of the available data.
Lopatka, Martin; Sigman, Michael E; Sjerps, Marjan J; Williams, Mary R; Vivó-Truyols, Gabriel
2015-07-01
Forensic chemical analysis of fire debris addresses the question of whether ignitable liquid residue is present in a sample and, if so, what type. Evidence evaluation regarding this question is complicated by interference from pyrolysis products of the substrate materials present in a fire. A method is developed to derive a set of class-conditional features for the evaluation of such complex samples. The use of a forensic reference collection allows characterization of the variation in complex mixtures of substrate materials and ignitable liquids even when the dominant feature is not specific to an ignitable liquid. Making use of a novel method for data imputation under complex mixing conditions, a distribution is modeled for the variation between pairs of samples containing similar ignitable liquid residues. Examining the covariance of variables within the different classes allows different weights to be placed on features more important in discerning the presence of a particular ignitable liquid residue. Performance of the method is evaluated using a database of total ion spectrum (TIS) measurements of ignitable liquid and fire debris samples. These measurements include 119 nominal masses measured by GC-MS and averaged across a chromatographic profile. Ignitable liquids are labeled using the American Society for Testing and Materials (ASTM) E1618 standard class definitions. Statistical analysis is performed in the class-conditional feature space wherein new forensic traces are represented based on their likeness to known samples contained in a forensic reference collection. The demonstrated method uses forensic reference data as the basis of probabilistic statements concerning the likelihood of the obtained analytical results given the presence of ignitable liquid residue of each of the ASTM classes (including a substrate only class). When prior probabilities of these classes can be assumed, these likelihoods can be connected to class probabilities. In order to compare the performance of this method to previous work, a uniform prior was assumed, resulting in an 81% accuracy for an independent test of 129 real burn samples. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Atwood, E.L.
1958-01-01
Response bias errors are studied by comparing questionnaire responses from waterfowl hunters using four large public hunting areas with actual hunting data from these areas during two hunting seasons. To the extent that the data permit, the sources of the error in the responses were studied and the contribution of each type to the total error was measured. Response bias errors, including both prestige and memory bias, were found to be very large as compared to non-response and sampling errors. Good fits were obtained with the seasonal kill distribution of the actual hunting data and the negative binomial distribution and a good fit was obtained with the distribution of total season hunting activity and the semi-logarithmic curve. A comparison of the actual seasonal distributions with the questionnaire response distributions revealed that the prestige and memory bias errors are both positive. The comparisons also revealed the tendency for memory bias errors to occur at digit frequencies divisible by five and for prestige bias errors to occur at frequencies which are multiples of the legal daily bag limit. A graphical adjustment of the response distributions was carried out by developing a smooth curve from those frequency classes not included in the predictable biased frequency classes referred to above. Group averages were used in constructing the curve, as suggested by Ezekiel [1950]. The efficiency of the technique described for reducing response bias errors in hunter questionnaire responses on seasonal waterfowl kill is high in large samples. The graphical method is not as efficient in removing response bias errors in hunter questionnaire responses on seasonal hunting activity where an average of 60 percent was removed.
Scheid, Patrick; Speck, Stephanie; Schwarzenberger, Rafael; Litzinger, Mark; Balczun, Carsten; Dobler, Gerhard
2016-10-01
Ixodes ricinus is a well-known vector of different human pathogens including Rickettsia helvetica. The role of wild mammals in the distribution and probable maintenance of Rickettsia in nature is still to be determined. We therefore investigated various parasites from different wild mammals as well as companion animals for the presence of Rickettsia. A total of 606 I. ricinus, 38 Cephenemyia stimulator (botfly larvae), one Dermacentor reticulatus, 24 Haematopinus suis (hog lice) and 30 Lipoptena cervi (deer flies) were collected from free-ranging animals during seasonal hunting, and from companion animals. Sample sites included hunting leases at three main sampling areas and five additional areas in West and Central Germany. All collected parasites were screened for Rickettsia spp. and I. ricinus were investigated for tick-borne encephalitis virus (TBEV) in addition. While no TBEV was detected, the minimum infection rate (MIR) of I. ricinus with Rickettsia was 4.1% referring to all sampling sites and up to 6.9% at the main sampling site in Koblenz area. Sequencing of a fragment of the ompB gene identified R. helvetica. Approximately one third (29.5%) of the animals carried Rickettsia-positive ticks and the MIR in ticks infesting wild mammals ranged from 4.1% (roe deer) to 9.5%. These data affirm the widespread distribution of R. helvetica in Germany. One botfly larva from roe deer also harboured R. helvetica. Botfly larvae are obligate parasites of the nasal cavity, pharynx and throat of cervids and feed on cell fragments and blood. Based on this one might hypothesise that R. helvetica likely induces rickettsemia in cervids thus possibly contributing to maintenance and distribution of this rickettsia in the field. Copyright © 2016 Elsevier GmbH. All rights reserved.
Brannock, Pamela M; Sharma, Jyotsna; Bik, Holly M; Thomas, W Kelley; Halanych, Kenneth M
2017-09-01
Nematodes are an abundant and diverse interstitial component of sedimentary habitats that have been reported to serve as important bioindicators. Though the 2010 Deepwater Horizon (DWH) disaster occurred 60 km offshore in the Gulf of Mexico (GOM) at a depth of 1525 m, oil rose to the surface and washed ashore, subjecting large segments of coastline in the northern GOM to contamination. Previous metabarcoding work shows intertidal nematode communities were negatively affected by the oil spill. Here we examine the subsequent recovery of nematode community structure at five sites along the Alabama coast over a two-year period. The latter part of the study (July 2011-July 2012) also included an examination of nematode vertical distribution in intertidal sediments. Results showed nematode composition within this region was more influenced by sample locality than time and depth. The five sampling sites were characterized by distinct nematode assemblages that varied by sampling dates. Nematode diversity decreased four months after the oil spill but increased after one year, returning to previous levels at all sites except Bayfront Park (BP). There was no significant difference among nematode assemblages in reference to vertical distribution. Although the composition of nematode assemblages changed, the feeding guilds they represented were not significantly different even though some variation was noted. Data from morphological observations integrated with metabarcoding data indicated similar spatial variation in nematode distribution patterns, indicating the potential of using these faster approaches to examine overall disturbance impact trends within communities. Heterogeneity of microhabitats in the intertidal zone indicates that future sampling and fine-scale studies of nematodes are needed to examine such anthropogenic effects. Copyright © 2017 Elsevier Ltd. All rights reserved.
Niederstätter, Harald; Rampl, Gerhard; Erhart, Daniel; Pitterl, Florian; Oberacher, Herbert; Neuhuber, Franz; Hausner, Isolde; Gassner, Christoph; Schennach, Harald; Berger, Burkhard; Parson, Walther
2012-01-01
The small alpine district of East Tyrol (Austria) has an exceptional demographic history. It was contemporaneously inhabited by members of the Romance, the Slavic and the Germanic language groups for centuries. Since the Late Middle Ages, however, the population of the principally agrarian-oriented area is solely Germanic speaking. Historic facts about East Tyrol's colonization are rare, but spatial density-distribution analysis based on the etymology of place-names has facilitated accurate spatial mapping of the various language groups' former settlement regions. To test for present-day Y chromosome population substructure, molecular genetic data were compared to the information attained by the linguistic analysis of pasture names. The linguistic data were used for subdividing East Tyrol into two regions of former Romance (A) and Slavic (B) settlement. Samples from 270 East Tyrolean men were genotyped for 17 Y-chromosomal microsatellites (Y-STRs) and 27 single nucleotide polymorphisms (Y-SNPs). Analysis of the probands' surnames revealed no evidence for spatial genetic structuring. Also, spatial autocorrelation analysis did not indicate significant correlation between genetic (Y-STR haplotypes) and geographic distance. Haplogroup R-M17 chromosomes, however, were absent in region A, but constituted one of the most frequent haplogroups in region B. The R-M343 (R1b) clade showed a marked and complementary frequency distribution pattern in these two regions. To further test East Tyrol's modern Y-chromosomal landscape for geographic patterning attributable to the early history of settlement in this alpine area, principal coordinates analysis was performed. The Y-STR haplotypes from region A clearly clustered with those of Romance reference populations and the samples from region B matched best with Germanic speaking reference populations. The combined use of onomastic and molecular genetic data revealed and mapped the marked structuring of the distribution of Y chromosomes in an alpine region that has been culturally homogeneous for centuries.
Niederstätter, Harald; Rampl, Gerhard; Erhart, Daniel; Pitterl, Florian; Oberacher, Herbert; Neuhuber, Franz; Hausner, Isolde; Gassner, Christoph; Schennach, Harald; Berger, Burkhard; Parson, Walther
2012-01-01
The small alpine district of East Tyrol (Austria) has an exceptional demographic history. It was contemporaneously inhabited by members of the Romance, the Slavic and the Germanic language groups for centuries. Since the Late Middle Ages, however, the population of the principally agrarian-oriented area is solely Germanic speaking. Historic facts about East Tyrol's colonization are rare, but spatial density-distribution analysis based on the etymology of place-names has facilitated accurate spatial mapping of the various language groups' former settlement regions. To test for present-day Y chromosome population substructure, molecular genetic data were compared to the information attained by the linguistic analysis of pasture names. The linguistic data were used for subdividing East Tyrol into two regions of former Romance (A) and Slavic (B) settlement. Samples from 270 East Tyrolean men were genotyped for 17 Y-chromosomal microsatellites (Y-STRs) and 27 single nucleotide polymorphisms (Y-SNPs). Analysis of the probands' surnames revealed no evidence for spatial genetic structuring. Also, spatial autocorrelation analysis did not indicate significant correlation between genetic (Y-STR haplotypes) and geographic distance. Haplogroup R-M17 chromosomes, however, were absent in region A, but constituted one of the most frequent haplogroups in region B. The R-M343 (R1b) clade showed a marked and complementary frequency distribution pattern in these two regions. To further test East Tyrol's modern Y-chromosomal landscape for geographic patterning attributable to the early history of settlement in this alpine area, principal coordinates analysis was performed. The Y-STR haplotypes from region A clearly clustered with those of Romance reference populations and the samples from region B matched best with Germanic speaking reference populations. The combined use of onomastic and molecular genetic data revealed and mapped the marked structuring of the distribution of Y chromosomes in an alpine region that has been culturally homogeneous for centuries. PMID:22848647
Lorini, C; Rossetti, F; Palazzoni, S; Comodo, N; Bonaccorsi, G
2008-01-01
Aim of this survey is to identify those filamentous fungi which parasite Boletus edulis and its group and check the potential presence of secondary metabolites, specifically aflatoxin B1, total aflatoxins and ochratoxin A, in order to assess the risk to consumers' health. Forty samples of dried Boletus edulis, collected by two food industries which distribute the product in many Italian regions, have been analysed. The sampling plan has been conducted from November 2005 to March 2006, collecting 50 g from each commercial category of dried Boletus edulis available in the factory at the time of sampling. All the samples have been tested by visual macroscopic and stereoscopic assays; for some samples--those referred to commercial category presumably at higher risk--we have performed cultural assays as well, typization of isolated micromycetes, extraction and quantification of aflatoxins and ochratoxin A. Mycotoxin detection has been made by HPLC, using the UNI EN 14123 and UNI EN 14132 standard methods, respectively applied to aflatoxins determination in peanuts, pistachios, figs and paprika and to ochratoxin A in barley and coffee. Non pathogenic micromycetes, common in food products, have been frequently observed in cultural assays, while Aspergillus flavus and Aspergillus niger have been found in some samples. However the concentration of aflatoxins was always under the quantification limit. The survey confirm that, if the cold chain is kept throughout the process and the distribution, Boletus edulis and analogue mycetes are not a favourable substratum for the growth and the development of moulds.
Multi-GHz Synchronous Waveform Acquisition With Real-Time Pattern-Matching Trigger Generation
NASA Astrophysics Data System (ADS)
Kleinfelder, Stuart A.; Chiang, Shiuh-hua Wood; Huang, Wei
2013-10-01
A transient waveform capture and digitization circuit with continuous synchronous 2-GHz sampling capability and real-time programmable windowed trigger generation has been fabricated and tested. Designed in 0.25 μm CMOS, the digitizer contains a circular array of 128 sample and hold circuits for continuous sample acquisition, and attains 2-GHz sample speeds with over 800-MHz analog bandwidth. Sample clock generation is synchronous, combining a phase-locked loop for high-speed clock generation and a high-speed fully-differential shift register for distributing clocks to all 128 sample circuits. Using two comparators per sample, the sampled voltage levels are compared against two reference levels, a high threshold and a low threshold, that are set via per-comparator digital to analog converters (DACs). The 256 per-comparator 5-bit DACs compensate for comparator offsets and allow for fine reference level adjustment. The comparator results are matched in 8-sample-wide windows against up to 72 programmable patterns in real time using an on-chip programmable logic array. Each 8-sample trigger window is equivalent to 4 ns of acquisition, overlapped sample by sample in a circular fashion through the entire 128-sample array. The 72 pattern-matching trigger criteria can be programmed to be any combination of High-above the high threshold, Low-below the low threshold, Middle-between the two thresholds, or “Don't Care”-any state is accepted. A trigger pattern of “HLHLHLHL,” for example, watches for a waveform that is oscillating at about 1 GHz given the 2-GHz sample rate. A trigger is flagged in under 20 ns if there is a match, after which sampling is stopped, and on-chip digitization can proceed via 128 parallel 10-bit converters, or off-chip conversion can proceed via an analog readout. The chip exceeds 11 bits of dynamic range, nets over 800-MHz -3-dB bandwidth in a realistic system, and jitter in the PLL-based sampling clock has been measured to be about 1 part per million, RMS.
Torres, D P; Martins-Teixeira, M B; Silva, E F; Queiroz, H M
2012-01-01
A very simple and rapid method for the determination of total mercury in fish samples using the Direct Mercury Analyser DMA-80 was developed. In this system, a previously weighted portion of fresh fish is combusted and the released mercury is selectively trapped in a gold amalgamator. Upon heating, mercury is desorbed from the amalgamator, an atomic absorption measurement is performed and the mercury concentration is calculated. Some experimental parameters have been studied and optimised. In this study the sample mass was about 100.0 mg. The relative standard deviation was lower than 8.0% for all measurements of solid samples. Two calibration curves against aqueous standard solutions were prepared through the low linear range from 2.5 to 20.0 ng of Hg, and the high linear range from 25.0 to 200.0 ng of Hg, for which a correlation coefficient better than 0.997 was achieved, as well as a normal distribution of the residuals. Mercury reference solutions were prepared in 5.0% v/v nitric acid medium. Lyophilised fish tissues were also analysed; however, the additional procedure had no advantage over the direct analysis of the fresh fish, and additionally increased the total analytical process time. A fish tissue reference material, IAEA-407, was analysed and the mercury concentration was in agreement with the certified value, according to the t-test at a 95% confidence level. The limit of quantification (LOQ), based on a mercury-free sample, was 3.0 µg kg(-1). This LOQ is in accordance with performance criteria required by the Commission Regulation No. 333/2007. Simplicity and high efficiency, without the need for any sample preparation procedure, are some of the qualities of the proposed method.
Mathis, Michael R.; Schechtman, Samuel A.; Engoren, Milo C.; Shanks, Amy M.; Thompson, Aleda; Kheterpal, Sachin; Tremper, Kevin K.
2016-01-01
Background Assessment of need for intravascular volume resuscitation remains challenging for anesthesiologists. Dynamic waveform indices, including systolic- and pulse-pressure variation (SPV/PPV), are demonstrated as reliable measures of fluid-responsiveness for mechanically ventilated patients. Despite widespread use, real-world reference distributions for SPV and PPV values have not been established for euvolemic intraoperative patients. The authors sought to establish SPV and PPV reference distributions and assess impact of modifying factors. Methods The authors evaluated adult patients undergoing general anesthetics for elective non-cardiac surgery. Median SPV and PPV over a 50-minute post-induction period were noted for each case. Modifying factors including body-mass index, age, ventilator settings, positioning, and hemodynamic management were studied via univariate and multivariable analyses. For SPV values, effects of data entry method (manually-entered versus automated recorded) were similarly studied. Results Among 1,791 cases, per-case median SPV and PPV values formed non-parametric distributions. For each distribution, median values, interquartile ranges, and reference intervals (2.5th-97.5th percentile) were respectively noted: these included manually-entered SPV (6.0, 5.0-7.0, 3.0-11.0 mmHg), automated SPV (4.7, 3.9-6.0, 2.2-10.4 mmHg), and automated PPV (7.0, 5.0-9.0, 2.0-16.0%). Non-supine positioning and preoperative beta blocker were independently associated with altered SPV and PPV, whereas ventilator tidal volume >8 mL/kg ideal body weight and peak inspiratory pressure >16 cm H2O demonstrated independent associations for SPV only. Conclusions This study establishes real-world SPV and PPV reference distributions absent in the current literature. Through a consideration of reference distributions and modifying factors, our study provides further evidence for assessing intraoperative volume status and fluid management therapies. PMID:27906705
Neutrino oscillation parameter sampling with MonteCUBES
NASA Astrophysics Data System (ADS)
Blennow, Mattias; Fernandez-Martinez, Enrique
2010-01-01
We present MonteCUBES ("Monte Carlo Utility Based Experiment Simulator"), a software package designed to sample the neutrino oscillation parameter space through Markov Chain Monte Carlo algorithms. MonteCUBES makes use of the GLoBES software so that the existing experiment definitions for GLoBES, describing long baseline and reactor experiments, can be used with MonteCUBES. MonteCUBES consists of two main parts: The first is a C library, written as a plug-in for GLoBES, implementing the Markov Chain Monte Carlo algorithm to sample the parameter space. The second part is a user-friendly graphical Matlab interface to easily read, analyze, plot and export the results of the parameter space sampling. Program summaryProgram title: MonteCUBES (Monte Carlo Utility Based Experiment Simulator) Catalogue identifier: AEFJ_v1_0 Program summary URL:http://cpc.cs.qub.ac.uk/summaries/AEFJ_v1_0.html Program obtainable from: CPC Program Library, Queen's University, Belfast, N. Ireland Licensing provisions: GNU General Public Licence No. of lines in distributed program, including test data, etc.: 69 634 No. of bytes in distributed program, including test data, etc.: 3 980 776 Distribution format: tar.gz Programming language: C Computer: MonteCUBES builds and installs on 32 bit and 64 bit Linux systems where GLoBES is installed Operating system: 32 bit and 64 bit Linux RAM: Typically a few MBs Classification: 11.1 External routines: GLoBES [1,2] and routines/libraries used by GLoBES Subprograms used:Cat Id ADZI_v1_0, Title GLoBES, Reference CPC 177 (2007) 439 Nature of problem: Since neutrino masses do not appear in the standard model of particle physics, many models of neutrino masses also induce other types of new physics, which could affect the outcome of neutrino oscillation experiments. In general, these new physics imply high-dimensional parameter spaces that are difficult to explore using classical methods such as multi-dimensional projections and minimizations, such as those used in GLoBES [1,2]. Solution method: MonteCUBES is written as a plug-in to the GLoBES software [1,2] and provides the necessary methods to perform Markov Chain Monte Carlo sampling of the parameter space. This allows an efficient sampling of the parameter space and has a complexity which does not grow exponentially with the parameter space dimension. The integration of the MonteCUBES package with the GLoBES software makes sure that the experimental definitions already in use by the community can also be used with MonteCUBES, while also lowering the learning threshold for users who already know GLoBES. Additional comments: A Matlab GUI for interpretation of results is included in the distribution. Running time: The typical running time varies depending on the dimensionality of the parameter space, the complexity of the experiment, and how well the parameter space should be sampled. The running time for our simulations [3] with 15 free parameters at a Neutrino Factory with O(10) samples varied from a few hours to tens of hours. References:P. Huber, M. Lindner, W. Winter, Comput. Phys. Comm. 167 (2005) 195, hep-ph/0407333. P. Huber, J. Kopp, M. Lindner, M. Rolinec, W. Winter, Comput. Phys. Comm. 177 (2007) 432, hep-ph/0701187. S. Antusch, M. Blennow, E. Fernandez-Martinez, J. Lopez-Pavon, arXiv:0903.3986 [hep-ph].
Analytical approaches to the determination of phosphorus partitioning patterns in sediments.
Pardo, P; Rauret, G; López-Sánchez, J F
2003-04-01
Three methods for phosphorus fractionation in sediments based on chemical extractions have been applied to fourteen aquatic sediment samples of different origin and characteristics. Two of the methods used different approaches to obtain the inorganic fractions. The Hieltjes and Lijklema procedure (HL) uses strong acids or bases, whereas the Golterman procedure (G) uses chelating reagents. The third one, the Standards, Measurements and Testing (SMT) protocol, was proposed in the frame of the SMT Programme (European Commission) which aimed to provide harmonisation and the validation of such methodologies. This harmonised procedure was also used for the certification of the extractable phosphorus contents in a sediment certified reference material (CRM BCR 684). Principal component analysis (PCA) was used to group sediments according to their composition and the three extraction methods were applied to the samples including CRM BCR 684. The data obtained show that there is some correlation between the results from the three methods when considering the organic and the residual fractions together. The SMT and the HL methods are the most comparable, whereas the G method, using a different type of reagent, yields different distribution patterns depending on sample composition. In relation to the inorganic phosphorus, the three methods give similar information, although the distribution between non-apatite and apatite fractions can be different.
Anco, Corey; Kolokotronis, Sergios-Orestis; Henschel, Philipp; Cunningham, Seth W; Amato, George; Hekkala, Evon
2018-04-01
Once found throughout Africa and Eurasia, the leopard (Panthera pardus) was recently uplisted from Near Threatened to Vulnerable by the International Union for the Conservation of Nature (IUCN). Historically, more than 50% of the leopard's global range occurred in continental Africa, yet sampling from this part of the species' distribution is only sparsely represented in prior studies examining patterns of genetic variation at the continental or global level. Broad sampling to determine baseline patterns of genetic variation throughout the leopard's historical distribution is important, as these measures are currently used by the IUCN to direct conservation priorities and management plans. By including data from 182 historical museum specimens, faecal samples from ongoing field surveys, and published sequences representing sub-Saharan Africa, we identify previously unrecognized genetic diversity in African leopards. Our mtDNA data indicates high levels of divergence among regional populations and strongly differentiated lineages in West Africa on par with recent studies of other large vertebrates. We provide a reference benchmark of genetic diversity in African leopards against which future monitoring can be compared. These findings emphasize the utility of historical museum collections in understanding the processes that shape present biodiversity. Additionally, we suggest future research to clarify African leopard taxonomy and to differentiate between delineated units requiring monitoring or conservation action.
Galaxy And Mass Assembly (GAMA): bivariate functions of Hα star-forming galaxies
NASA Astrophysics Data System (ADS)
Gunawardhana, M. L. P.; Hopkins, A. M.; Taylor, E. N.; Bland-Hawthorn, J.; Norberg, P.; Baldry, I. K.; Loveday, J.; Owers, M. S.; Wilkins, S. M.; Colless, M.; Brown, M. J. I.; Driver, S. P.; Alpaslan, M.; Brough, S.; Cluver, M.; Croom, S.; Kelvin, L.; Lara-López, M. A.; Liske, J.; López-Sánchez, A. R.; Robotham, A. S. G.
2015-02-01
We present bivariate luminosity and stellar mass functions of Hα star-forming galaxies drawn from the Galaxy And Mass Assembly (GAMA) survey. While optically deep spectroscopic observations of GAMA over a wide sky area enable the detection of a large number of 0.001 < SFRHα (M⊙ yr-1) < 100 galaxies, the requirement for an Hα detection in targets selected from an r-band magnitude-limited survey leads to an incompleteness due to missing optically faint star-forming galaxies. Using z < 0.1 bivariate distributions as a reference we model the higher-z distributions, thereby approximating a correction for the missing optically faint star-forming galaxies to the local star formation rate (SFR) and M densities. Furthermore, we obtain the r-band luminosity functions (LFs) and stellar mass functions of Hα star-forming galaxies from the bivariate LFs. As our sample is selected on the basis of detected Hα emission, a direct tracer of ongoing star formation, this sample represents a true star-forming galaxy sample, and is drawn from both photometrically classified blue and red subpopulations, though mostly from the blue population. On average 20-30 per cent of red galaxies at all stellar masses are star forming, implying that these galaxies may be dusty star-forming systems.
Laboratory-based bidirectional reflectance distribution functions of radiometric tarps.
Georgiev, Georgi T; Butler, James J
2008-06-20
Laboratory-based bidirectional reflectance distribution functions (BRDFs) of radiometric tarp samples used in the vicarious calibration of Earth remote sensing satellite instruments are presented in this paper. The results illustrate the BRDF dependence on the orientation of the tarps' weft and warp threads. The study was performed using the GSFC scatterometer at incident zenith angles of 0 degrees, 10 degrees, and 30 degrees; scatter zenith angles from 0 degrees to 60 degrees; and scatter azimuth angles of 0 degrees, 45 degrees, 90 degrees, 135 degrees, and 180 degrees. The wavelengths were 485 nm, 550 nm, 633 nm, and 800 nm. The tarp's weft and warp dependence on BRDF is well defined at all measurement geometries and wavelengths. The BRDF difference can be as high as 8% at 0 degrees incident angle and 12% at 30 degrees incident angle. The fitted BRDF data show a very small discrepancy from the measured ones. New data on the forward and backscatter properties of radiometric tarps are reported. The backward scatter is well pronounced for the white samples. The black sample has well-pronounced forward scatter. The provided BRDF characterization of radiometric tarps is an excellent reference for anyone interested in using tarps for radiometric calibrations. The results are NIST traceable.
Zou, An-Min; Kumar, Krishna Dev
2012-07-01
This brief considers the attitude coordination control problem for spacecraft formation flying when only a subset of the group members has access to the common reference attitude. A quaternion-based distributed attitude coordination control scheme is proposed with consideration of the input saturation and with the aid of the sliding-mode observer, separation principle theorem, Chebyshev neural networks, smooth projection algorithm, and robust control technique. Using graph theory and a Lyapunov-based approach, it is shown that the distributed controller can guarantee the attitude of all spacecraft to converge to a common time-varying reference attitude when the reference attitude is available only to a portion of the group of spacecraft. Numerical simulations are presented to demonstrate the performance of the proposed distributed controller.
Confidence of compliance: a Bayesian approach for percentile standards.
McBride, G B; Ellis, J C
2001-04-01
Rules for assessing compliance with percentile standards commonly limit the number of exceedances permitted in a batch of samples taken over a defined assessment period. Such rules are commonly developed using classical statistical methods. Results from alternative Bayesian methods are presented (using beta-distributed prior information and a binomial likelihood), resulting in "confidence of compliance" graphs. These allow simple reading of the consumer's risk and the supplier's risks for any proposed rule. The influence of the prior assumptions required by the Bayesian technique on the confidence results is demonstrated, using two reference priors (uniform and Jeffreys') and also using optimistic and pessimistic user-defined priors. All four give less pessimistic results than does the classical technique, because interpreting classical results as "confidence of compliance" actually invokes a Bayesian approach with an extreme prior distribution. Jeffreys' prior is shown to be the most generally appropriate choice of prior distribution. Cost savings can be expected using rules based on this approach.
Paddock, Christopher D; Denison, Amy M; Lash, R Ryan; Liu, Lindy; Bollweg, Brigid C; Dahlgren, F Scott; Kanamura, Cristina T; Angerami, Rodrigo N; Pereira dos Santos, Fabiana C; Brasil Martines, Roosecelis; Karpathy, Sandor E
2014-09-01
Rocky Mountain spotted fever (RMSF), a tick-borne zoonosis caused by Rickettsia rickettsii, is among the deadliest of all infectious diseases. To identify the distribution of various genotypes of R. rickettsii associated with fatal RMSF, we applied molecular typing methods to samples of DNA extracted from formalin-fixed, paraffin-embedded tissue specimens obtained at autopsy from 103 case-patients from seven countries who died of RMSF. Complete sequences of one or more intergenic regions were amplified from tissues of 30 (29%) case-patients and revealed a distribution of genotypes consisting of four distinct clades, including the Hlp clade, regarded previously as a non-pathogenic strain of R. rickettsii. Distinct phylogeographic patterns were identified when composite case-patient and reference strain data were mapped to the state and country of origin. The phylogeography of R. rickettsii is likely determined by ecological and environmental factors that exist independently of the distribution of a particular tick vector. © The American Society of Tropical Medicine and Hygiene.
Phylogeography of Rickettsia rickettsii Genotypes Associated with Fatal Rocky Mountain Spotted Fever
Paddock, Christopher D.; Denison, Amy M.; Lash, R. Ryan; Liu, Lindy; Bollweg, Brigid C.; Dahlgren, F. Scott; Kanamura, Cristina T.; Angerami, Rodrigo N.; Pereira dos Santos, Fabiana C.; Brasil Martines, Roosecelis; Karpathy, Sandor E.
2014-01-01
Rocky Mountain spotted fever (RMSF), a tick-borne zoonosis caused by Rickettsia rickettsii, is among the deadliest of all infectious diseases. To identify the distribution of various genotypes of R. rickettsii associated with fatal RMSF, we applied molecular typing methods to samples of DNA extracted from formalin-fixed, paraffin-embedded tissue specimens obtained at autopsy from 103 case-patients from seven countries who died of RMSF. Complete sequences of one or more intergenic regions were amplified from tissues of 30 (29%) case-patients and revealed a distribution of genotypes consisting of four distinct clades, including the Hlp clade, regarded previously as a non-pathogenic strain of R. rickettsii. Distinct phylogeographic patterns were identified when composite case-patient and reference strain data were mapped to the state and country of origin. The phylogeography of R. rickettsii is likely determined by ecological and environmental factors that exist independently of the distribution of a particular tick vector. PMID:24957541
Varga, Z.; Mayer, K.; Bonamici, C. E.; ...
2015-05-11
The results of a joint effort by expert nuclear forensic laboratories in the area of age dating of uranium, i.e. the elapsed time since the last chemical purification of the material are presented and discussed. Completely separated uranium materials of known production date were distributed among the laboratories, and the samples were dated according to routine laboratory procedures by the measurement of the ²²⁰Th/²³⁴U ratio. The measurement results were in good agreement with the known production date showing that the concept for preparing uranium age dating reference material based on complete separation is valid. Detailed knowledge of the laboratory proceduresmore » used for uranium age dating allows the identification of possible improvements in the current protocols and the development of improved practice in the future. The availability of age dating reference materials as well as the evolvement of the age dating best-practice protocol will increase the relevance and applicability of age dating as part of the tool-kit available for nuclear forensic investigations.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Varga, Z.; Mayer, K.; Bonamici, C. E.
The results of a joint effort by expert nuclear forensic laboratories in the area of age dating of uranium, i.e. the elapsed time since the last chemical purification of the material are presented and discussed. Completely separated uranium materials of known production date were distributed among the laboratories, and the samples were dated according to routine laboratory procedures by the measurement of the ²²⁰Th/²³⁴U ratio. The measurement results were in good agreement with the known production date showing that the concept for preparing uranium age dating reference material based on complete separation is valid. Detailed knowledge of the laboratory proceduresmore » used for uranium age dating allows the identification of possible improvements in the current protocols and the development of improved practice in the future. The availability of age dating reference materials as well as the evolvement of the age dating best-practice protocol will increase the relevance and applicability of age dating as part of the tool-kit available for nuclear forensic investigations.« less
A Simple Method for Automated Equilibration Detection in Molecular Simulations.
Chodera, John D
2016-04-12
Molecular simulations intended to compute equilibrium properties are often initiated from configurations that are highly atypical of equilibrium samples, a practice which can generate a distinct initial transient in mechanical observables computed from the simulation trajectory. Traditional practice in simulation data analysis recommends this initial portion be discarded to equilibration, but no simple, general, and automated procedure for this process exists. Here, we suggest a conceptually simple automated procedure that does not make strict assumptions about the distribution of the observable of interest in which the equilibration time is chosen to maximize the number of effectively uncorrelated samples in the production timespan used to compute equilibrium averages. We present a simple Python reference implementation of this procedure and demonstrate its utility on typical molecular simulation data.
NASA Astrophysics Data System (ADS)
Hu, Zixi; Yao, Zhewei; Li, Jinglai
2017-03-01
Many scientific and engineering problems require to perform Bayesian inference for unknowns of infinite dimension. In such problems, many standard Markov Chain Monte Carlo (MCMC) algorithms become arbitrary slow under the mesh refinement, which is referred to as being dimension dependent. To this end, a family of dimensional independent MCMC algorithms, known as the preconditioned Crank-Nicolson (pCN) methods, were proposed to sample the infinite dimensional parameters. In this work we develop an adaptive version of the pCN algorithm, where the covariance operator of the proposal distribution is adjusted based on sampling history to improve the simulation efficiency. We show that the proposed algorithm satisfies an important ergodicity condition under some mild assumptions. Finally we provide numerical examples to demonstrate the performance of the proposed method.
A simple method for automated equilibration detection in molecular simulations
Chodera, John D.
2016-01-01
Molecular simulations intended to compute equilibrium properties are often initiated from configurations that are highly atypical of equilibrium samples, a practice which can generate a distinct initial transient in mechanical observables computed from the simulation trajectory. Traditional practice in simulation data analysis recommends this initial portion be discarded to equilibration, but no simple, general, and automated procedure for this process exists. Here, we suggest a conceptually simple automated procedure that does not make strict assumptions about the distribution of the observable of interest, in which the equilibration time is chosen to maximize the number of effectively uncorrelated samples in the production timespan used to compute equilibrium averages. We present a simple Python reference implementation of this procedure, and demonstrate its utility on typical molecular simulation data. PMID:26771390
Water Quality in Small Community Distribution Systems. A Reference Guide for Operators
The U.S. Environmental Protection Agency (EPA) has developed this reference guide to assist the operators and managers of small- and medium-sized public water systems. This compilation provides a comprehensive picture of the impact of the water distribution system network on dist...
Characterization of Lone Pine, California, tremolite asbestos and preparation of research material
Harper, Martin; Van Gosen, Bradley S.; Crankshaw, Owen S; Doorn, Stacy S; Ennis, J. Todd; Harrison, Sara E
2014-01-01
Well-characterized amphibole asbestos mineral samples are required for use as analytical standards and in future research projects. Currently, the National Institute for Standards and Technology Standard Reference Material samples of asbestos are listed as ‘Discontinued’. The National Institute for Occupational Safety and Health (NIOSH) has a goal under the Asbestos Roadmap of locating and characterizing research materials for future use. Where an initial characterization analysis determines that a collected material is appropriate for use as a research material in terms of composition and asbestiform habit, sufficient amounts of the material will be collected to make it publicly available. An abandoned mine near Lone Pine, California, contains a vein of tremolite asbestos, which was the probable source of a reference material that has been available for the past 17 years from the Health and Safety Laboratory (HSL) in the UK. Newly collected fibrous vein material from this mine was analyzed at Research Triangle Institute (RTI International) with some additional analysis by the US Geological Survey’s Denver Microbeam Laboratory. The analysis at RTI International included: (i) polarized light microscopy (PLM) with a determination of principal optical properties; (ii) X-ray diffraction; (iii) transmission electron microscopy, including energy dispersive X-ray spectroscopy and selected-area electron diffraction; and (iv) spindle stage analysis using PLM to determine whether individual fibers and bundles of the samples were polycrystalline or single-crystal cleavage fragments. The overall findings of the study indicated that the material is tremolite asbestos with characteristics substantially similar to the earlier distributed HSL reference material. A larger quantity of material was prepared by sorting, acid-washing and mixing for sub-division into vials of ~10g each. These vials have been transferred from NIOSH to RTI International, from where they can be obtained on request.
Characterization of Lone Pine, California, Tremolite Asbestos and Preparation of Research Material
Harper, Martin; Van Gosen, Bradley; Crankshaw, Owen S.; Doorn, Stacy S.; Ennis, Todd J.; Harrison, Sara E.
2016-01-01
Well-characterized amphibole asbestos mineral samples are required for use as analytical standards and in future research projects. Currently, the National Institute for Standards and Technology Standard Reference Material samples of asbestos are listed as ‘Discontinued’. The National Institute for Occupational Safety and Health (NIOSH) has a goal under the Asbestos Roadmap of locating and characterizing research materials for future use. Where an initial characterization analysis determines that a collected material is appropriate for use as a research material in terms of composition and asbestiform habit, sufficient amounts of the material will be collected to make it publicly available. An abandoned mine near Lone Pine, California, contains a vein of tremolite asbestos, which was the probable source of a reference material that has been available for the past 17 years from the Health and Safety Laboratory (HSL) in the UK. Newly collected fibrous vein material from this mine was analyzed at Research Triangle Institute (RTI International) with some additional analysis by the US Geological Survey’s Denver Microbeam Laboratory. The analysis at RTI International included: (i) polarized light microscopy (PLM) with a determination of principal optical properties; (ii) X-ray diffraction; (iii) transmission electron microscopy, including energy dispersive X-ray spectroscopy and selected-area electron diffraction; and (iv) spindle stage analysis using PLM to determine whether individual fibers and bundles of the samples were polycrystalline or single-crystal cleavage fragments. The overall findings of the study indicated that the material is tremolite asbestos with characteristics substantially similar to the earlier distributed HSL reference material. A larger quantity of material was prepared by sorting, acid-washing and mixing for sub-division into vials of ~10 g each. These vials have been transferred from NIOSH to RTI International, from where they can be obtained on request. PMID:25268000
Bias Assessment of General Chemistry Analytes using Commutable Samples.
Koerbin, Gus; Tate, Jillian R; Ryan, Julie; Jones, Graham Rd; Sikaris, Ken A; Kanowski, David; Reed, Maxine; Gill, Janice; Koumantakis, George; Yen, Tina; St John, Andrew; Hickman, Peter E; Simpson, Aaron; Graham, Peter
2014-11-01
Harmonisation of reference intervals for routine general chemistry analytes has been a goal for many years. Analytical bias may prevent this harmonisation. To determine if analytical bias is present when comparing methods, the use of commutable samples, or samples that have the same properties as the clinical samples routinely analysed, should be used as reference samples to eliminate the possibility of matrix effect. The use of commutable samples has improved the identification of unacceptable analytical performance in the Netherlands and Spain. The International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) has undertaken a pilot study using commutable samples in an attempt to determine not only country specific reference intervals but to make them comparable between countries. Australia and New Zealand, through the Australasian Association of Clinical Biochemists (AACB), have also undertaken an assessment of analytical bias using commutable samples and determined that of the 27 general chemistry analytes studied, 19 showed sufficiently small between method biases as to not prevent harmonisation of reference intervals. Application of evidence based approaches including the determination of analytical bias using commutable material is necessary when seeking to harmonise reference intervals.
Mental health epidemiological research in South America: recent findings
Silva de Lima, Maurício; Garcia de Oliveira Soares, Bernardo; de Jesus Mari, Jair
2004-01-01
This paper aims to review the recent mental health epidemiological research conducted in South America. The Latin American and the Caribbean (LILACS) database was searched from 1999 to 2003 using a specific strategy for identification of cohort, case-control and cross-sectional population-based studies in South America. The authors screened references and identified relevant studies. Further studies were obtained contacting local experts in epidemiology. 140 references were identified, and 12 studies were selected. Most selected studies explored the prevalence and risk factors for common mental disorders, and several of them used sophisticated methods of sample selection and analysis. There is a need for improving the quality of psychiatric journals in Latin America, and for increasing the distribution and access to research data. Regionally relevant problems such as violence and substance abuse should be considered in designing future investigations in this area. PMID:16633474
Tissue temperature distribution measurement by MRI and laser immunology for cancer treatment
NASA Astrophysics Data System (ADS)
Chen, Yichao; Gnyawali, Surya C.; Wu, Feng; Liu, Hong; Tesiram, Yasvir A.; Abbott, Andrew; Towner, Rheal A.; Chen, Wei R.
2007-02-01
In cancer treatment and immune response enhancement research, Magnetic Resonance Imaging (MRI) is an ideal method for non-invasive, three-dimensional temperature measurement. We used a 7.1-Tesla magnetic resonance imager for ex vivo tissues and small animal to determine temperature distribution of target tissue during laser irradiation. The feasibility of imaging is approved with high spatial resolution and high signal-noise- ratio. Tissue-simulating gel phantom gel, biological tissues, and tumor-bearing animals were used in the experiments for laser treatment and MR imaging. Thermal couple measurement of temperature in target samples was used for system calibration. An 805-nm laser was used to irradiate the samples with a laser power in the range of 1 to 2.5 watts. Using the MRI system and a specially developed processing algorithm, a clear temperature distribution matrix in the target tissue and surrounding tissue was obtained. The temperature profiles show that the selective laser photothermal effect could result in tissue temperature elevation in a range of 10 to 45 °C. The temperature resolution of the measurement was about 0.37°C including the total system error. The spatial resolution was 0.4 mm (128x128 pixels with field of view of 5.5x5.5 cm). The temperature distribution provided in vivo thermal information and future reference for optimizing dye concentration and irradiation parameters to achieve optimal thermal effects in cancer treatment.
NASA Astrophysics Data System (ADS)
Hönicke, Philipp; Krämer, Markus; Lühl, Lars; Andrianov, Konstantin; Beckhoff, Burkhard; Dietsch, Rainer; Holz, Thomas; Kanngießer, Birgit; Weißbach, Danny; Wilhein, Thomas
2018-07-01
With the advent of both modern X-ray fluorescence (XRF) methods and improved analytical reliability requirements the demand for suitable reference samples has increased. Especially in nanotechnology with the very low areal mass depositions, quantification becomes considerably more difficult. However, the availability of suited reference samples is drastically lower than the demand. Physical vapor deposition techniques have been enhanced significantly in the last decade driven by the need for extremely precise film parameters in multilayer production. We have applied those techniques for the development of layer-like reference samples with mass depositions in the ng-range and well below for Ca, Cu, Pb, Mo, Pd, Pb, La, Fe and Ni. Numerous other elements would also be possible. Several types of reference samples were fabricated: multi-elemental layer and extremely low (sub-monolayer) samples for various applications in XRF and total-reflection XRF analysis. Those samples were characterized and compared at three different synchrotron radiation beamlines at the BESSY II electron storage ring employing the reference-free XRF approach based on physically calibrated instrumentation. In addition, the homogeneity of the multi-elemental coatings was checked at the P04 beamline at DESY. The measurements demonstrate the high precision achieved in the manufacturing process as well as the versatility of application fields for the presented reference samples.
Fearon, Elizabeth; Chabata, Sungai T; Thompson, Jennifer A; Cowan, Frances M; Hargreaves, James R
2017-09-14
While guidance exists for obtaining population size estimates using multiplier methods with respondent-driven sampling surveys, we lack specific guidance for making sample size decisions. To guide the design of multiplier method population size estimation studies using respondent-driven sampling surveys to reduce the random error around the estimate obtained. The population size estimate is obtained by dividing the number of individuals receiving a service or the number of unique objects distributed (M) by the proportion of individuals in a representative survey who report receipt of the service or object (P). We have developed an approach to sample size calculation, interpreting methods to estimate the variance around estimates obtained using multiplier methods in conjunction with research into design effects and respondent-driven sampling. We describe an application to estimate the number of female sex workers in Harare, Zimbabwe. There is high variance in estimates. Random error around the size estimate reflects uncertainty from M and P, particularly when the estimate of P in the respondent-driven sampling survey is low. As expected, sample size requirements are higher when the design effect of the survey is assumed to be greater. We suggest a method for investigating the effects of sample size on the precision of a population size estimate obtained using multipler methods and respondent-driven sampling. Uncertainty in the size estimate is high, particularly when P is small, so balancing against other potential sources of bias, we advise researchers to consider longer service attendance reference periods and to distribute more unique objects, which is likely to result in a higher estimate of P in the respondent-driven sampling survey. ©Elizabeth Fearon, Sungai T Chabata, Jennifer A Thompson, Frances M Cowan, James R Hargreaves. Originally published in JMIR Public Health and Surveillance (http://publichealth.jmir.org), 14.09.2017.
NASA Astrophysics Data System (ADS)
Wiedensohler, A.; Birmili, W.; Nowak, A.; Sonntag, A.; Weinhold, K.; Merkel, M.; Wehner, B.; Tuch, T.; Pfeifer, S.; Fiebig, M.; Fjäraa, A. M.; Asmi, E.; Sellegri, K.; Depuy, R.; Venzac, H.; Villani, P.; Laj, P.; Aalto, P.; Ogren, J. A.; Swietlicki, E.; Williams, P.; Roldin, P.; Quincey, P.; Hüglin, C.; Fierz-Schmidhauser, R.; Gysel, M.; Weingartner, E.; Riccobono, F.; Santos, S.; Grüning, C.; Faloon, K.; Beddows, D.; Harrison, R.; Monahan, C.; Jennings, S. G.; O'Dowd, C. D.; Marinoni, A.; Horn, H.-G.; Keck, L.; Jiang, J.; Scheckman, J.; McMurry, P. H.; Deng, Z.; Zhao, C. S.; Moerman, M.; Henzing, B.; de Leeuw, G.; Löschau, G.; Bastian, S.
2012-03-01
Mobility particle size spectrometers often referred to as DMPS (Differential Mobility Particle Sizers) or SMPS (Scanning Mobility Particle Sizers) have found a wide range of applications in atmospheric aerosol research. However, comparability of measurements conducted world-wide is hampered by lack of generally accepted technical standards and guidelines with respect to the instrumental set-up, measurement mode, data evaluation as well as quality control. Technical standards were developed for a minimum requirement of mobility size spectrometry to perform long-term atmospheric aerosol measurements. Technical recommendations include continuous monitoring of flow rates, temperature, pressure, and relative humidity for the sheath and sample air in the differential mobility analyzer. We compared commercial and custom-made inversion routines to calculate the particle number size distributions from the measured electrical mobility distribution. All inversion routines are comparable within few per cent uncertainty for a given set of raw data. Furthermore, this work summarizes the results from several instrument intercomparison workshops conducted within the European infrastructure project EUSAAR (European Supersites for Atmospheric Aerosol Research) and ACTRIS (Aerosols, Clouds, and Trace gases Research InfraStructure Network) to determine present uncertainties especially of custom-built mobility particle size spectrometers. Under controlled laboratory conditions, the particle number size distributions from 20 to 200 nm determined by mobility particle size spectrometers of different design are within an uncertainty range of around ±10% after correcting internal particle losses, while below and above this size range the discrepancies increased. For particles larger than 200 nm, the uncertainty range increased to 30%, which could not be explained. The network reference mobility spectrometers with identical design agreed within ±4% in the peak particle number concentration when all settings were done carefully. The consistency of these reference instruments to the total particle number concentration was demonstrated to be less than 5%. Additionally, a new data structure for particle number size distributions was introduced to store and disseminate the data at EMEP (European Monitoring and Evaluation Program). This structure contains three levels: raw data, processed data, and final particle size distributions. Importantly, we recommend reporting raw measurements including all relevant instrument parameters as well as a complete documentation on all data transformation and correction steps. These technical and data structure standards aim to enhance the quality of long-term size distribution measurements, their comparability between different networks and sites, and their transparency and traceability back to raw data.
Nelson, Sarah C.; Stilp, Adrienne M.; Papanicolaou, George J.; Taylor, Kent D.; Rotter, Jerome I.; Thornton, Timothy A.; Laurie, Cathy C.
2016-01-01
Imputation is commonly used in genome-wide association studies to expand the set of genetic variants available for analysis. Larger and more diverse reference panels, such as the final Phase 3 of the 1000 Genomes Project, hold promise for improving imputation accuracy in genetically diverse populations such as Hispanics/Latinos in the USA. Here, we sought to empirically evaluate imputation accuracy when imputing to a 1000 Genomes Phase 3 versus a Phase 1 reference, using participants from the Hispanic Community Health Study/Study of Latinos. Our assessments included calculating the correlation between imputed and observed allelic dosage in a subset of samples genotyped on a supplemental array. We observed that the Phase 3 reference yielded higher accuracy at rare variants, but that the two reference panels were comparable at common variants. At a sample level, the Phase 3 reference improved imputation accuracy in Hispanic/Latino samples from the Caribbean more than for Mainland samples, which we attribute primarily to the additional reference panel samples available in Phase 3. We conclude that a 1000 Genomes Project Phase 3 reference panel can yield improved imputation accuracy compared with Phase 1, particularly for rare variants and for samples of certain genetic ancestry compositions. Our findings can inform imputation design for other genome-wide association studies of participants with diverse ancestries, especially as larger and more diverse reference panels continue to become available. PMID:27346520
Self-referenced continuous-variable quantum key distribution
Soh, Daniel B. S.; Sarovar, Mohan; Camacho, Ryan
2017-01-24
Various technologies for continuous-variable quantum key distribution without transmitting a transmitter's local oscillator are described herein. A receiver on an optical transmission channel uses an oscillator signal generated by a light source at the receiver's location to perform interferometric detection on received signals. An optical reference pulse is sent by the transmitter on the transmission channel and the receiver computes a phase offset of the transmission based on quadrature measurements of the reference pulse. The receiver can then compensate for the phase offset between the transmitter's reference and the receiver's reference when measuring quadratures of received data pulses.
Sample size allocation for food item radiation monitoring and safety inspection.
Seto, Mayumi; Uriu, Koichiro
2015-03-01
The objective of this study is to identify a procedure for determining sample size allocation for food radiation inspections of more than one food item to minimize the potential risk to consumers of internal radiation exposure. We consider a simplified case of food radiation monitoring and safety inspection in which a risk manager is required to monitor two food items, milk and spinach, in a contaminated area. Three protocols for food radiation monitoring with different sample size allocations were assessed by simulating random sampling and inspections of milk and spinach in a conceptual monitoring site. Distributions of (131)I and radiocesium concentrations were determined in reference to (131)I and radiocesium concentrations detected in Fukushima prefecture, Japan, for March and April 2011. The results of the simulations suggested that a protocol that allocates sample size to milk and spinach based on the estimation of (131)I and radiocesium concentrations using the apparent decay rate constants sequentially calculated from past monitoring data can most effectively minimize the potential risks of internal radiation exposure. © 2014 Society for Risk Analysis.
Spread of the dust temperature distribution in circumstellar disks
NASA Astrophysics Data System (ADS)
Heese, S.; Wolf, S.; Dutrey, A.; Guilloteau, S.
2017-07-01
Context. Accurate temperature calculations for circumstellar disks are particularly important for their chemical evolution. Their temperature distribution is determined by the optical properties of the dust grains, which, among other parameters, depend on their radius. However, in most disk studies, only average optical properties and thus an average temperature is assumed to account for an ensemble of grains with different radii. Aims: We investigate the impact of subdividing the grain radius distribution into multiple sub-intervals on the resulting dust temperature distribution and spectral energy distribution (SED). Methods: The temperature distribution, the relative grain surface below a certain temperature, the freeze-out radius, and the SED were computed for two different scenarios: (1) Radius distribution represented by 16 logarithmically distributed radius intervals, and (2) radius distribution represented by a single grain species with averaged optical properties (reference). Results: Within the considered parameter range, I.e., of grain radii between 5 nm and 1 mm and an optically thin and thick disk with a parameterized density distribution, we obtain the following results: in optically thin disk regions, the temperature spread can be as large as 63% and the relative grain surface below a certain temperature is lower than in the reference disk. With increasing optical depth, the difference in the midplane temperature and the relative grain surface below a certain temperature decreases. Furthermore, below 20 K, this fraction is higher for the reference disk than for the case of multiple grain radii, while it shows the opposite behavior for temperatures above this threshold. The thermal emission in the case of multiple grain radii at short wavelengths is stronger than for the reference disk. The freeze-out radius (snowline) is a function of grain radius, spanning a radial range between the coldest and warmest grain species of 30 AU.
NASA Astrophysics Data System (ADS)
Raquin, Aude; Moreira, Manuel Alexis; Guillon, Fabien
2008-09-01
An outstanding problem in understanding the origin of the gaseous phase, particularly the rare gas compositions in magmatic rocks, is the ubiquitous atmospheric component in bulk rock samples, and whether this atmospheric component is a late stage contamination of the sample, or a recycled component though sediments or altered oceanic crust. In the present study we address this problem by analyzing single vesicles from the "popping rock 2∏D43" sample from the Mid-Atlantic Ridge using a UV laser ablation system. We have determined both elemental and isotopic compositions of He, Ne and Ar in single vesicles as well as Kr and Xe abundances. All vesicles analyzed have an isotopic composition identical to the referred degassed mantle value estimated from this same sample, despite analyzing vesicles from a wide size distribution. The atmospheric component, which is always detected in bulk samples by crushing or heating, was not detected in the single vesicles. This implies that the recycling of atmospheric noble gases in the mantle cannot explain the air-like component of this sample. The addition of the atmospheric component must occur either during the eruption, or after sample recovery.
78 FR 57293 - Distribution of Reference Biological Standards and Biological Preparations
Federal Register 2010, 2011, 2012, 2013, 2014
2013-09-18
... DEPARTMENT OF HEALTH AND HUMAN SERVICES 42 CFR Part 7 [Docket No. CDC-2013-0013] RIN 0920-AA52 Distribution of Reference Biological Standards and Biological Preparations AGENCY: Centers for Disease Control and Prevention (HHS/CDC), Department of Health and Human Services (HHS). ACTION: Confirmation of...
An Exploration of WFC3/IR Dark Current Variation
NASA Astrophysics Data System (ADS)
Sunnquist, B.; Baggett, S.; Long, K. S.
2017-02-01
We use a collection of darks spanning September 2009 to June 2016 to study variations in the dark current in the IR detector on WFC3. Although the darks possess a similar signal pattern across the detector, we find that their median dark rates vary by as much as 0.014 DN/s (0.032 e-/s). The distribution of these median values has a triangular shape with a mean and standard deviation of 0.021 ± 0.0029 DN/s (0.049 ± 0.0069 e-/s). We observe a long term time-dependence in the inboard vertical reference pixel and zeroth read signals; however, these differences do not noticeably affect the calibrated dark signals, and we conclude that the WFC3/IR dark current levels continue to remain stable since launch. The inboard reference pixel signals exhibit a unique, but consistent, pattern around the detector, but this pattern does not evolve noticeably with the median of the science pixels, and a quadrant or row-based reference pixel subtraction strategy does not reduce the spread between the median dark rates. We notice a slight drift in the inboard reference pixel signals up the dark ramps, and the intensity of this drift is related to the median dark current in the science pixels. This holds true using either the horizontal or vertical reference pixels and for darks with a variety of sample sequences.
Winterfield, Craig; van de Voort, F R
2014-12-01
The Fluid Life Corporation assessed and implemented Fourier transform infrared spectroscopy (FTIR)-based methods using American Society for Testing and Materials (ASTM)-like stoichiometric reactions for determination of acid and base number for in-service mineral-based oils. The basic protocols, quality control procedures, calibration, validation, and performance of these new quantitative methods are assessed. ASTM correspondence is attained using a mixed-mode calibration, using primary reference standards to anchor the calibration, supplemented by representative sample lubricants analyzed by ASTM procedures. A partial least squares calibration is devised by combining primary acid/base reference standards and representative samples, focusing on the main spectral stoichiometric response with chemometrics assisting in accounting for matrix variability. FTIR(AN/BN) methodology is precise, accurate, and free of most interference that affects ASTM D664 and D4739 results. Extensive side-by-side operational runs produced normally distributed differences with mean differences close to zero and standard deviations of 0.18 and 0.26 mg KOH/g, respectively. Statistically, the FTIR methods are a direct match to the ASTM methods, with superior performance in terms of analytical throughput, preparation time, and solvent use. FTIR(AN/BN) analysis is a viable, significant advance for in-service lubricant analysis, providing an economic means of trending samples instead of tedious and expensive conventional ASTM(AN/BN) procedures. © 2014 Society for Laboratory Automation and Screening.
Combining Soil Databases for Topsoil Organic Carbon Mapping in Europe.
Aksoy, Ece; Yigini, Yusuf; Montanarella, Luca
2016-01-01
Accuracy in assessing the distribution of soil organic carbon (SOC) is an important issue because of playing key roles in the functions of both natural ecosystems and agricultural systems. There are several studies in the literature with the aim of finding the best method to assess and map the distribution of SOC content for Europe. Therefore this study aims searching for another aspect of this issue by looking to the performances of using aggregated soil samples coming from different studies and land-uses. The total number of the soil samples in this study was 23,835 and they're collected from the "Land Use/Cover Area frame Statistical Survey" (LUCAS) Project (samples from agricultural soil), BioSoil Project (samples from forest soil), and "Soil Transformations in European Catchments" (SoilTrEC) Project (samples from local soil data coming from six different critical zone observatories (CZOs) in Europe). Moreover, 15 spatial indicators (slope, aspect, elevation, compound topographic index (CTI), CORINE land-cover classification, parent material, texture, world reference base (WRB) soil classification, geological formations, annual average temperature, min-max temperature, total precipitation and average precipitation (for years 1960-1990 and 2000-2010)) were used as auxiliary variables in this prediction. One of the most popular geostatistical techniques, Regression-Kriging (RK), was applied to build the model and assess the distribution of SOC. This study showed that, even though RK method was appropriate for successful SOC mapping, using combined databases was not helpful to increase the statistical significance of the method results for assessing the SOC distribution. According to our results; SOC variation was mainly affected by elevation, slope, CTI, average temperature, average and total precipitation, texture, WRB and CORINE variables for Europe scale in our model. Moreover, the highest average SOC contents were found in the wetland areas; agricultural areas have much lower soil organic carbon content than forest and semi natural areas; Ireland, Sweden and Finland has the highest SOC, on the contrary, Portugal, Poland, Hungary, Spain, Italy have the lowest values with the average 3%.
Combining Soil Databases for Topsoil Organic Carbon Mapping in Europe
Aksoy, Ece
2016-01-01
Accuracy in assessing the distribution of soil organic carbon (SOC) is an important issue because of playing key roles in the functions of both natural ecosystems and agricultural systems. There are several studies in the literature with the aim of finding the best method to assess and map the distribution of SOC content for Europe. Therefore this study aims searching for another aspect of this issue by looking to the performances of using aggregated soil samples coming from different studies and land-uses. The total number of the soil samples in this study was 23,835 and they’re collected from the “Land Use/Cover Area frame Statistical Survey” (LUCAS) Project (samples from agricultural soil), BioSoil Project (samples from forest soil), and “Soil Transformations in European Catchments” (SoilTrEC) Project (samples from local soil data coming from six different critical zone observatories (CZOs) in Europe). Moreover, 15 spatial indicators (slope, aspect, elevation, compound topographic index (CTI), CORINE land-cover classification, parent material, texture, world reference base (WRB) soil classification, geological formations, annual average temperature, min-max temperature, total precipitation and average precipitation (for years 1960–1990 and 2000–2010)) were used as auxiliary variables in this prediction. One of the most popular geostatistical techniques, Regression-Kriging (RK), was applied to build the model and assess the distribution of SOC. This study showed that, even though RK method was appropriate for successful SOC mapping, using combined databases was not helpful to increase the statistical significance of the method results for assessing the SOC distribution. According to our results; SOC variation was mainly affected by elevation, slope, CTI, average temperature, average and total precipitation, texture, WRB and CORINE variables for Europe scale in our model. Moreover, the highest average SOC contents were found in the wetland areas; agricultural areas have much lower soil organic carbon content than forest and semi natural areas; Ireland, Sweden and Finland has the highest SOC, on the contrary, Portugal, Poland, Hungary, Spain, Italy have the lowest values with the average 3%. PMID:27011357
Pratt, Victoria M; Everts, Robin E; Aggarwal, Praful; Beyer, Brittany N; Broeckel, Ulrich; Epstein-Baak, Ruth; Hujsak, Paul; Kornreich, Ruth; Liao, Jun; Lorier, Rachel; Scott, Stuart A; Smith, Chingying Huang; Toji, Lorraine H; Turner, Amy; Kalman, Lisa V
2016-01-01
Pharmacogenetic testing is increasingly available from clinical laboratories. However, only a limited number of quality control and other reference materials are currently available to support clinical testing. To address this need, the Centers for Disease Control and Prevention-based Genetic Testing Reference Material Coordination Program, in collaboration with members of the pharmacogenetic testing community and the Coriell Cell Repositories, has characterized 137 genomic DNA samples for 28 genes commonly genotyped by pharmacogenetic testing assays (CYP1A1, CYP1A2, CYP2A6, CYP2B6, CYP2C8, CYP2C9, CYP2C19, CYP2D6, CYP2E1, CYP3A4, CYP3A5, CYP4F2, DPYD, GSTM1, GSTP1, GSTT1, NAT1, NAT2, SLC15A2, SLC22A2, SLCO1B1, SLCO2B1, TPMT, UGT1A1, UGT2B7, UGT2B15, UGT2B17, and VKORC1). One hundred thirty-seven Coriell cell lines were selected based on ethnic diversity and partial genotype characterization from earlier testing. DNA samples were coded and distributed to volunteer testing laboratories for targeted genotyping using a number of commercially available and laboratory developed tests. Through consensus verification, we confirmed the presence of at least 108 variant pharmacogenetic alleles. These samples are also being characterized by other pharmacogenetic assays, including next-generation sequencing, which will be reported separately. Genotyping results were consistent among laboratories, with most differences in allele assignments attributed to assay design and variability in reported allele nomenclature, particularly for CYP2D6, UGT1A1, and VKORC1. These publicly available samples will help ensure the accuracy of pharmacogenetic testing. Copyright © 2016 American Society for Investigative Pathology and the Association for Molecular Pathology. Published by Elsevier Inc. All rights reserved.
Wang, Zhendi; Li, K; Lambert, P; Yang, Chun
2007-01-12
On 15 August 2001, a tire fire took place at the Pneu Lavoie Facility in Gatineau, Quebec, in which 4000 to 6000 new and recycled tires were stored along with other potentially hazardous materials. Comprehensive gas chromatography-mass spectrometry (GC-MS) analyses were performed on the tire fire samples to facilitate detailed chemical composition characterization of toxic polycyclic aromatic hydrocarbons (PAHs) and other organic compounds in samples. It is found that significant amounts of PAHs, particularly the high-ring-number PAHs, were generated during the fire. In total, 165 PAH compounds including 13 isomers of molecular weight (MW) 302, 10 isomers of MW 278, 10 isomers of MW 276, 7 isomers of MW 252, 7 isomers of MW 228, and 8 isomers of MW 216 PAHs were positively identified in the tire fire wipe samples for the first time. Numerous S-, O-, and N-containing PAH compounds were also detected. The identification and characterization of the PAH isomers was mainly based on: (1) a positive match of mass spectral data of the PAH isomers with the NIST authentic mass spectra database; (2) a positive match of the GC retention indices (I) of PAHs with authentic standards and with those reported in the literature; (3) agreement of the PAH elution order with the NIST (US National Institute of Standards and Technology) Standard Reference Material 1597 for complex mixture of PAHs from coal tar; (4) a positive match of the distribution patterns of PAH isomers in the SIM mode between the tire fire samples and the NIST Standard Reference Materials and well-characterized reference oils. Quantitation of target PAHs was done on the GC-MS in the selected ion monitoring (SIM) mode using the internal standard method. The relative response factors (RRF) for target PAHs were obtained from analyses of authentic PAH standard compounds. Alkylated PAH homologues were quantitated using straight baseline integration of each level of alkylation.
NASA Technical Reports Server (NTRS)
Wang, H. J.; Cunnold, D. M.
2002-01-01
Ozone distributions have been derived from recent satellite-based measurements by the Stratospheric Aerosol and Gas Experiment (SAGE), the Halogen Occultation Experiment (HALOE) and the Microwave Limb Sounder (MLS). An ozone distribution for the period April 1992 to March 1993 and covering pressures from 0.1 to 100 mb and from 80 deg N to 80 deg S is summarized. At pressures less than 1 mb, separate distributions are given for daytime and nighttime conditions. The resulting distributions extend to somewhat higher latitudes and lower altitudes than previous COSPAR reference atmosphere distributions for ozone. Differences versus the most recent COSPAR distribution by Keating et al are illustrated.
Age of onset of recurrent respiratory papillomatosis: a distribution analysis.
San Giorgi, M R M; van den Heuvel, E R; Tjon Pian Gi, R E A; Brunings, J W; Chirila, M; Friedrich, G; Golusinski, W; Graupp, M; Horcasitas Pous, R A; Ilmarinen, T; Jackowska, J; Koelmel, J C; Ferran Vilà, F; Weichbold, V; Wierzbicka, M; Dikkers, F G
2016-10-01
Distribution of age of onset of recurrent respiratory papillomatosis (RRP) is generally described to be bimodal, with peaks at approximately 5 years and 30 years. This assumption has never been scientifically confirmed, and authors tend to refer to an article that does not describe distribution. Knowledge of the distribution of age of onset is important for virological and epidemiological comprehension. The objective of this study was to determine the distribution of age of onset of RRP in a large international sample. Cross-sectional distribution analysis. Laryngologists from 12 European hospitals provided information on date of birth and date of onset of all their RRP patients treated between 1998 and 2012. Centers that exclusively treated either patients with juvenile onset RRP or patients with adult onset RRP, or were less accessible for one of these groups, were excluded to prevent skewness. A mixture model was implemented to describe distribution of age of onset. The best fitting model was selected using the Bayesian information criterion. Six hundred and thirty-nine patients were included in the analysis. Age of onset was described by a three component mixture distribution with lognormally distributed components. Recurrent respiratory papillomatosis starts at three median ages 7, 35 and 64 years. Distribution of age of onset of RRP shows three peaks. In addition to the already adopted idea of age peaks at paediatric and adult age, there is an additional peak around the age of 64. © 2015 John Wiley & Sons Ltd.
Walters, David M.; Otter, Ryan R.; Kraus, Johanna M.; Mills, Marc A.
2018-01-01
We investigated PCB contamination at the Ashtabula River Area of Concern (AOC) following remedial dredging using araneid and tetragnathid spiders. PCB concentrations remain elevated in the AOC compared to reference conditions. Patterns of contamination were strikingly similar between taxa, but were higher in tetragnathids at the most contaminated sites. Spider PCB homolog distributions identified two PCB sources to the AOC. Based on these findings, we recommend situations where these taxa can be used singularly, in concert, or combined into a composite “spider” sample to assess environmental contamination.
Non-destructive terahertz imaging of illicit drugs using spectral fingerprints
NASA Astrophysics Data System (ADS)
Kawase, Kodo; Ogawa, Yuichi; Watanabe, Yuuki; Inoue, Hiroyuki
2003-10-01
The absence of non-destructive inspection techniques for illicit drugs hidden in mail envelopes has resulted in such drugs being smuggled across international borders freely. We have developed a novel basic technology for terahertz imaging, which allows detection and identification of drugs concealed in envelopes, by introducing the component spatial pattern analysis. The spatial distributions of the targets are obtained from terahertz multispectral transillumination images, using absorption spectra measured with a tunable terahertz-wave source. The samples we used were methamphetamine and MDMA, two of the most widely consumed illegal drugs in Japan, and aspirin as a reference.
Flameless atomic-absorption determination of gold in geological materials
Meier, A.L.
1980-01-01
Gold in geologic material is dissolved using a solution of hydrobromic acid and bromine, extracted with methyl isobutyl ketone, and determined using an atomic-absorption spectrophotometer equipped with a graphite furnace atomizer. A comparison of results obtained by this flameless atomic-absorption method on U.S. Geological Survey reference rocks and geochemical samples with reported values and with results obtained by flame atomic-absorption shows that reasonable accuracy is achieved with improved precision. The sensitivity, accuracy, and precision of the method allows acquisition of data on the distribution of gold at or below its crustal abundance. ?? 1980.
Development of internal forest soil reference samples and testing of digestion methods
J.E. Hislop; J.W. Hornbeck; S.W. Bailey; R.A. Hallett
1998-01-01
Our research requires determinations of total elemental concentrations of forest soils. The lack of certified forest soil reference materials led us to develop internal reference samples. Samples were collected from three soil horizons (Oa, B, and C) at three locations having forested, acidic soils similar to those we commonly analyze. A shatterbox was used to...
An analytic linear accelerator source model for GPU-based Monte Carlo dose calculations.
Tian, Zhen; Li, Yongbao; Folkerts, Michael; Shi, Feng; Jiang, Steve B; Jia, Xun
2015-10-21
Recently, there has been a lot of research interest in developing fast Monte Carlo (MC) dose calculation methods on graphics processing unit (GPU) platforms. A good linear accelerator (linac) source model is critical for both accuracy and efficiency considerations. In principle, an analytical source model should be more preferred for GPU-based MC dose engines than a phase-space file-based model, in that data loading and CPU-GPU data transfer can be avoided. In this paper, we presented an analytical field-independent source model specifically developed for GPU-based MC dose calculations, associated with a GPU-friendly sampling scheme. A key concept called phase-space-ring (PSR) was proposed. Each PSR contained a group of particles that were of the same type, close in energy and reside in a narrow ring on the phase-space plane located just above the upper jaws. The model parameterized the probability densities of particle location, direction and energy for each primary photon PSR, scattered photon PSR and electron PSR. Models of one 2D Gaussian distribution or multiple Gaussian components were employed to represent the particle direction distributions of these PSRs. A method was developed to analyze a reference phase-space file and derive corresponding model parameters. To efficiently use our model in MC dose calculations on GPU, we proposed a GPU-friendly sampling strategy, which ensured that the particles sampled and transported simultaneously are of the same type and close in energy to alleviate GPU thread divergences. To test the accuracy of our model, dose distributions of a set of open fields in a water phantom were calculated using our source model and compared to those calculated using the reference phase-space files. For the high dose gradient regions, the average distance-to-agreement (DTA) was within 1 mm and the maximum DTA within 2 mm. For relatively low dose gradient regions, the root-mean-square (RMS) dose difference was within 1.1% and the maximum dose difference within 1.7%. The maximum relative difference of output factors was within 0.5%. Over 98.5% passing rate was achieved in 3D gamma-index tests with 2%/2 mm criteria in both an IMRT prostate patient case and a head-and-neck case. These results demonstrated the efficacy of our model in terms of accurately representing a reference phase-space file. We have also tested the efficiency gain of our source model over our previously developed phase-space-let file source model. The overall efficiency of dose calculation was found to be improved by ~1.3-2.2 times in water and patient cases using our analytical model.
Reference values of whole-blood fatty acids by age and sex from European children aged 3-8 years.
Wolters, M; Schlenz, H; Foraita, R; Galli, C; Risé, P; Moreno, L A; Molnár, D; Russo, P; Veidebaum, T; Tornaritis, M; Vyncke, K; Eiben, G; Iacoviello, L; Ahrens, W
2014-09-01
To establish reference values for fatty acids (FA) especially for n-3 and n-6 long-chain polyunsaturated FAs (LC PUFA) in whole-blood samples from apparently healthy 3-8-year-old European children. The whole-blood FA composition was analysed and the age- and sex-specific distribution of FA was determined. Blood samples for FA analysis were taken from 2661 children of the IDEFICS (identification and prevention of dietary- and lifestyle-induced health effects in children and infants) study cohort. Children with obesity (n=454) and other diseases that are known to alter the FA composition (n=450) were excluded leaving 1653 participants in the reference population. The FA composition of whole blood was analysed from blood drops by a rapid, validated gas chromatographic method. Pearson correlation coefficients showed an age-dependent increase of C18:2n-6 and a decrease of C18:1n-9 in a subsample of normal weight boys and girls. Other significant correlations with age were weak and only seen either in boys or in girls, whereas most of the FA did not show any age dependence. For age-dependent n-3 and n-6 PUFA as well as for other FA that are correlated with age (16:0, C18:0 and C18:1n-9) percentiles analysed with the general additive model for location scale and shape are presented. A higher median in boys than in girls was observed for C20:3n-6, C20:4n-6 and C22:4n-6. Given the reported associations between FA status and health-related outcome, the provision of FA reference ranges may be useful for the interpretation of the FA status of children in epidemiological and clinical studies.
Simultaneous comparison and assessment of eight remotely sensed maps of Philippine forests
NASA Astrophysics Data System (ADS)
Estoque, Ronald C.; Pontius, Robert G.; Murayama, Yuji; Hou, Hao; Thapa, Rajesh B.; Lasco, Rodel D.; Villar, Merlito A.
2018-05-01
This article compares and assesses eight remotely sensed maps of Philippine forest cover in the year 2010. We examined eight Forest versus Non-Forest maps reclassified from eight land cover products: the Philippine Land Cover, the Climate Change Initiative (CCI) Land Cover, the Landsat Vegetation Continuous Fields (VCF), the MODIS VCF, the MODIS Land Cover Type product (MCD12Q1), the Global Tree Canopy Cover, the ALOS-PALSAR Forest/Non-Forest Map, and the GlobeLand30. The reference data consisted of 9852 randomly distributed sample points interpreted from Google Earth. We created methods to assess the maps and their combinations. Results show that the percentage of the Philippines covered by forest ranges among the maps from a low of 23% for the Philippine Land Cover to a high of 67% for GlobeLand30. Landsat VCF estimates 36% forest cover, which is closest to the 37% estimate based on the reference data. The eight maps plus the reference data agree unanimously on 30% of the sample points, of which 11% are attributable to forest and 19% to non-forest. The overall disagreement between the reference data and Philippine Land Cover is 21%, which is the least among the eight Forest versus Non-Forest maps. About half of the 9852 points have a nested structure such that the forest in a given dataset is a subset of the forest in the datasets that have more forest than the given dataset. The variation among the maps regarding forest quantity and allocation relates to the combined effects of the various definitions of forest and classification errors. Scientists and policy makers must consider these insights when producing future forest cover maps and when establishing benchmarks for forest cover monitoring.
Wang, Genhong; Chen, Yanfei; Zhang, Xiaoying; Bai, Bingchuan; Yan, Hao; Qin, Daoyuan; Xia, Qingyou
2018-06-01
The silkworm, Bombyx mori, is one of the world's most economically important insect. Surveying variations in gene expression among multiple tissue/organ samples will provide clues for gene function assignments and will be helpful for identifying genes related to economic traits or specific cellular processes. To ensure their accuracy, commonly used gene expression quantification methods require a set of stable reference genes for data normalization. In this study, 24 candidate reference genes were assessed in 10 tissue/organ samples of day 3 fifth-instar B. mori larvae using geNorm and NormFinder. The results revealed that, using the combination of the expression of BGIBMGA003186 and BGIBMGA008209 was the optimum choice for normalizing the expression data of the B. mori tissue/organ samples. The most stable gene, BGIBMGA003186, is recommended if just one reference gene is used. Moreover, the commonly used reference gene encoding cytoplasmic actin was the least appropriate reference gene of the samples investigated. The reliability of the selected reference genes was further confirmed by evaluating the expression profiles of two cathepsin genes. Our results may be useful for future studies involving the quantification of relative gene expression levels of different tissue/organ samples in B. mori. © 2018 Wiley Periodicals, Inc.
Li, Meng-Jiao; Ge, Miao; Wang, Cong-Xia; Cen, Min-Yi; Jiang, Ji-Lin; He, Jin-Wei; Lin, Qian-Yi; Liu, Xin
2016-08-20
To analyze the relationship between the reference values of fibrinogen (FIB) in healthy Chinese adults and geographical factors to provide scientific evidences for establishing the uniform standard. The reference values of FIB of 10701 Chinese healthy adults from 103 cities were collected to investigate their relationship with 18 geographical factors including spatial index, terrain index, climate index, and soil index. Geographical factors that significantly correlated with the reference values were selected for constructing the BP neural network model. The spatial distribution map of the reference value of FIB of healthy Chinese adults was fitted by disjunctive kriging interpolation. We used the 5-layer neural network and selected 2000 times of training covering 11 hidden layers to build the simulation rule for simulating the relationship between FIB and geographical environmental factors using the MATLAB software. s The reference value of FIB in healthy Chinese adults was significantly correlated with the latitude, sunshine duration, annual average temperature, annual average relative humidity, annual precipitation, annual range of air temperature, average annual soil gravel content, and soil cation exchange capacity (silt). The artificial neural networks were created to analyze the simulation of the selected indicators of geographical factors. The spatial distribution map of the reference values of FIB in healthy Chinese adults showed a distribution pattern that FIB levels were higher in the South and lower in the North, and higher in the East and lower in the West. When the geographical factors of a certain area are known, the reference values of FIB in healthy Chinese adults can be obtained by establishing the neural network mode or plotting the spatial distribution map.
Rigourd, V; Barnier, J P; Ferroni, A; Nicloux, M; Hachem, T; Magny, J F; Lapillonne, A; Frange, P; Nassif, X; Bille, E
2018-05-03
Three cases of Bacillus cereus infection or colonization occurred in the same region in France, and milk from the milk bank was suspected as a possible common source of contamination. All Batches delivered to the three cases complied with the requirements of the bacteriological reference method recommended by good practices guidelines. Still, a retrospective analysis with a more sensitive method showed one batch to contain B. cereus, however straincomparison revealed no epidemiological link betweenisolates from patients and those from the milk. Consequently, in accordance with the precautionary principle, we developed a new sensitive method for the screening of pasteurized milk for pathogenic bacteria. From January 1 to August 31, 2017, 2526 samples of pasteurized milk were prospectively included in the study. We showed that a 20 mL sample of pasteurized milk incubated for 18 h at 37 °C under aerobic conditions was favoring the detection of B. Cereus. The nonconformity rate was 6.3% for the reference method and 12.6% for the improved method (p < 0.0001). Nonconformity was due to the presence of B. cereus in 88.5% of cases for the improved method and 53% of cases for the reference method (p < 0.0001). Thus our new method is improves the microbiological safety of the product distributed and only moderately increases the rate of bacteriological nonconformity .
Armando García-Miranda, L; Contreras, I; Estrada, J A
2014-04-01
To determine reference values for full blood count parameters in a population of children 8 to 12 years old, living at an altitude of 2760 m above sea level. Our sample consisted of 102 individuals on whom a full blood count was performed. The parameters included: total number of red blood cells, platelets, white cells, and a differential count (millions/μl and %) of neutrophils, lymphocytes, monocytes, eosinophils and basophils. Additionally, we obtained values for hemoglobin, hematocrit, mean corpuscular volume, mean corpuscular hemoglobin, concentration of corpuscular hemoglobin and red blood cell distribution width. The results were statistically analyzed with a non-parametric test, to divide the sample in quartiles and obtain the lower and upper limits for our intervals. Moreover, the values for the intervals obtained from this analysis were compared to intervals obtained estimating+- 2 standard deviations above and below from our mean values. Our results showed significant differences compared to normal interval values reported for the adult Mexican population in most of the parameters studied. The full blood count is an important laboratory test used routinely for the initial assessment of a patient. Values of full blood counts in healthy individuals vary according to gender, age and geographic location; therefore, each population should have its own reference values. Copyright © 2013 Asociación Española de Pediatría. Published by Elsevier Espana. All rights reserved.
Chen, Xi; Du, Peng; Guan, Qing; Feng, Xu; Xu, Dong-qun; Lin, Shao-bin
2015-06-01
To investigate the characteristics of chemical constitute and pollution sources of aerosol fine particulate matter during haze-fog day in Beijing in winter 2013. The samples of PM2.5 were collected in Beijing from January to February, 2013. The technique of ICP-MS and ICP-AES coupled with procedure of bathing-ultrasonic extraction was applied to determine the concentration of 40 elements in the aerosol samples to analyze the characteristics of elements distribution statistically. The absolute principal factor method was used to apportion the pollution sources of PM2.5 during the haze weather in Beijing city in winter 2013. The results showed that during the period of sampling, the volume concentration of Li, Mn, Pb, S etc. obeyed normal distribution approximately, and according to National Ambient Air Quality Standard issued by Ministry of Environmental Protection of the People's Republic of China, the geometric mean concentration of As was twice the annual limit of standard reference, while Pb of some aerosol samples beyond the annual limit of standard reference respectively. The mass fraction of Fe, Zn, Pb, Ti accounted for over 0.1%, while that of Mn, Cu, As, Se etc. 0.01%. These elements were primary inorganic pollutants, and especially the hazards and sources of As and Pb should be concerned. There were 6 main pollution sources were chosen by the factor analysis method, including industrial dust and human beings activities, biomass combustion and building dust, soil and sand dusts, fossil fuel, electronic waste and metal smelting, with the variance contribution rate of 40.3%, 27.0%, 9.1%, 4.9%, 4.8% and 4.6% respectively. ICP-MS and ICP-AES can be applied to analyzing multi-elements in PM2.5 accurately and quickly to facilitate source apportionment, and it indicated that the relevant pollution sources should be considered and the effect of regional transferring of haze pollution sources should be taken into account, and specific measures should be taken for control.
Boisen, Mogens Karsbøl; Dehlendorff, Christian; Linnemann, Dorte; Schultz, Nicolai Aagaard; Jensen, Benny Vittrup; Høgdall, Estrid Vilma Solyom; Johansen, Julia Sidenius
2015-12-29
Archival formalin-fixed paraffin-embedded (FFPE) cancer tissue samples are a readily available resource for microRNA (miRNA) biomarker identification. No established standard for reference miRNAs in FFPE tissue exists. We sought to identify stable reference miRNAs for normalization of miRNA expression in FFPE tissue samples from patients with colorectal (CRC) and pancreatic (PC) cancer and to quantify the variability associated with sample age and fixation. High-throughput miRNA profiling results from 203 CRC and 256 PC FFPE samples as well as from 37 paired frozen/FFPE samples from nine other CRC tumors (methodological samples) were used. Candidate reference miRNAs were identified by their correlation with global mean expression. The stability of reference genes was analyzed according to published methods. The association between sample age and global mean miRNA expression was tested using linear regression. Variability was described using correlation coefficients and linear mixed effects models. Normalization effects were determined by changes in standard deviation and by hierarchical clustering. We created lists of 20 miRNAs with the best correlation to global mean expression in each cancer type. Nine of these miRNAs were present in both lists, and miR-103a-3p was the most stable reference miRNA for both CRC and PC FFPE tissue. The optimal number of reference miRNAs was 4 in CRC and 10 in PC. Sample age had a significant effect on global miRNA expression in PC (50% reduction over 20 years) but not in CRC. Formalin fixation for 2-6 days decreased miRNA expression 30-65%. Normalization using global mean expression reduced variability for technical and biological replicates while normalization using the expression of the identified reference miRNAs reduced variability only for biological replicates. Normalization only had a minor impact on clustering results. We identified suitable reference miRNAs for future miRNA expression experiments using CRC- and PC FFPE tissue samples. Formalin fixation decreased miRNA expression considerably, while the effect of increasing sample age was estimated to be negligible in a clinical setting.
Harmonising Reference Intervals for Three Calculated Parameters used in Clinical Chemistry.
Hughes, David; Koerbin, Gus; Potter, Julia M; Glasgow, Nicholas; West, Nic; Abhayaratna, Walter P; Cavanaugh, Juleen; Armbruster, David; Hickman, Peter E
2016-08-01
For more than a decade there has been a global effort to harmonise all phases of the testing process, with particular emphasis on the most frequently utilised measurands. In addition, it is recognised that calculated parameters derived from these measurands should also be a target for harmonisation. Using data from the Aussie Normals study we report reference intervals for three calculated parameters: serum osmolality, serum anion gap and albumin-adjusted serum calcium. The Aussie Normals study was an a priori study that analysed samples from 1856 healthy volunteers. The nine analytes used for the calculations in this study were measured on Abbott Architect analysers. The data demonstrated normal (Gaussian) distributions for the albumin-adjusted serum calcium, the anion gap (using potassium in the calculation) and the calculated serum osmolality (using both the Bhagat et al. and Smithline and Gardner formulae). To assess the suitability of these reference intervals for use as harmonised reference intervals, we reviewed data from the Royal College of Pathologists of Australasia/Australasian Association of Clinical Biochemists (RCPA/AACB) bias survey. We conclude that the reference intervals for the calculated serum osmolality (using the Smithline and Gardner formulae) may be suitable for use as a common reference interval. Although a common reference interval for albumin-adjusted serum calcium may be possible, further investigations (including a greater range of albumin concentrations) are needed. This is due to the bias between the Bromocresol Green (BCG) and Bromocresol Purple (BCP) methods at lower serum albumin concentrations. Problems with the measurement of Total CO 2 in the bias survey meant that we could not use the data for assessing the suitability of a common reference interval for the anion gap. Further study is required.
HERUS: the far-IR/submm spectral energy distributions of local ULIRGs and photometric atlas
NASA Astrophysics Data System (ADS)
Clements, D. L.; Pearson, C.; Farrah, D.; Greenslade, J.; Bernard-Salas, Jeronimo; González-Alfonso, E.; Afonso, J.; Efstathiou, A.; Rigopoulou, D.; Lebouteiller, V.; Hurley, P. D.; Spoon, H.
2018-04-01
We present the Herschel-SPIRE photometric atlas for a complete flux limited sample of 43 local ultraluminous infrared galaxies (ULIRGs), selected at 60 μm by IRAS, as part of the HERschel ULIRG Survey (HERUS). Photometry observations were obtained using the SPIRE instrument at 250, 350, and 500 μm. We describe these observations, present the results, and combine the new observations with data from IRAS to examine the far-infrared spectral energy distributions (SEDs) of these sources. We fit the observed SEDs of HERUS objects with a simple parametrized modified blackbody model, where temperature and emissivity β are free parameters. We compare the fitted values to those of non-ULIRG local galaxies, and find, in agreement with earlier results, that HERUS ULIRGs have warmer dust (median temperature T = 37.9 ± 4.7 K compared to 21.3 ± 3.4 K) but a similar β distribution (median β = 1.7 compared to 1.8) to the Herschel reference sample (HRS, Cortese et al. 2014) galaxies. Dust masses are found to be in the range of 107.5-109 M⊙, significantly higher than that of HRS sources. We compare our results for local ULIRGs with higher redshift samples selected at 250 and 850 μm. These latter sources generally have cooler dust and/or redder 100-to-250 μm colours than our 60 μm-selected ULIRGs. We show that this difference may in part be the result of the sources being selected at different wavelengths rather than being a simple indication of rapid evolution in the properties of the population.
Chen, Lei; Zhong, Hai-ying; Kuang, Jian-fei; Li, Jian-guo; Lu, Wang-jin; Chen, Jian-ye
2011-08-01
Reverse transcription quantitative real-time PCR (RT-qPCR) is a sensitive technique for quantifying gene expression, but its success depends on the stability of the reference gene(s) used for data normalization. Only a few studies on validation of reference genes have been conducted in fruit trees and none in banana yet. In the present work, 20 candidate reference genes were selected, and their expression stability in 144 banana samples were evaluated and analyzed using two algorithms, geNorm and NormFinder. The samples consisted of eight sample sets collected under different experimental conditions, including various tissues, developmental stages, postharvest ripening, stresses (chilling, high temperature, and pathogen), and hormone treatments. Our results showed that different suitable reference gene(s) or combination of reference genes for normalization should be selected depending on the experimental conditions. The RPS2 and UBQ2 genes were validated as the most suitable reference genes across all tested samples. More importantly, our data further showed that the widely used reference genes, ACT and GAPDH, were not the most suitable reference genes in many banana sample sets. In addition, the expression of MaEBF1, a gene of interest that plays an important role in regulating fruit ripening, under different experimental conditions was used to further confirm the validated reference genes. Taken together, our results provide guidelines for reference gene(s) selection under different experimental conditions and a foundation for more accurate and widespread use of RT-qPCR in banana.
NASA Astrophysics Data System (ADS)
Renno, A. D.; Merchel, S.; Michalak, P. P.; Munnik, F.; Wiedenbeck, M.
2010-12-01
Recent economic trends regarding the supply of rare metals readily justify scientific research into non-conventional raw materials, where a particular need is a better understanding of the relationship between mineralogy, microstructure and the distribution of key metals within ore deposits (geometallurgy). Achieving these goals will require an extensive usage of in-situ microanalytical techniques capable of spatially resolving material heterogeneities which can be key for understanding better resource utilization. The availability of certified reference materials (CRMs) is an essential prerequisite for (1) validating new analytical methods, (2) demonstrating data quality to the contracting authorities, (3) supporting method development and instrument calibration, and (4) establishing traceability between new analytical approaches and existing data sets. This need has led to the granting of funding by the European Union and the German Free State of Saxony for a program to develop such reference materials . This effort will apply the following strategies during the selection of the phases: (1) will use exclusively synthetic minerals, thereby providing large volumes of homogeneous starting material. (2) will focus on matrices which are capable of incorporating many ‘important’ elements while avoid exotic compositions which would not be optimal matrix matches. (3) will emphasise those phases which remain stable during the various microanalytical procedure. This initiative will assess the homogeneity of the reference materials at sampling sizes ranging between 50 and 1 µm; it is also intended to document crystal structural homogeneity too, as this too may potentially impact specific analytical methods. As far as possible both definitive methods as well as methods involving matrix corrections will be used for determining the compositions of the of the individual materials. A critical challenge will be the validation of the determination of analytes concentrations as sub-µg sampling masses. It is planned to cooperate with those who are interested in the development of such reference materials and we invite them to take part in round-robin exercises.
Adeli, Khosrow; Higgins, Victoria; Seccombe, David; Collier, Christine P; Balion, Cynthia M; Cembrowski, George; Venner, Allison A; Shaw, Julie
2017-11-01
Reference intervals are widely used decision-making tools in laboratory medicine, serving as health-associated standards to interpret laboratory test results. Numerous studies have shown wide variation in reference intervals, even between laboratories using assays from the same manufacturer. Lack of consistency in either sample measurement or reference intervals across laboratories challenges the expectation of standardized patient care regardless of testing location. Here, we present data from a national survey conducted by the Canadian Society of Clinical Chemists (CSCC) Reference Interval Harmonization (hRI) Working Group that examines variation in laboratory reference sample measurements, as well as pediatric and adult reference intervals currently used in clinical practice across Canada. Data on reference intervals currently used by 37 laboratories were collected through a national survey to examine the variation in reference intervals for seven common laboratory tests. Additionally, 40 clinical laboratories participated in a baseline assessment by measuring six analytes in a reference sample. Of the seven analytes examined, alanine aminotransferase (ALT), alkaline phosphatase (ALP), and creatinine reference intervals were most variable. As expected, reference interval variation was more substantial in the pediatric population and varied between laboratories using the same instrumentation. Reference sample results differed between laboratories, particularly for ALT and free thyroxine (FT4). Reference interval variation was greater than test result variation for the majority of analytes. It is evident that there is a critical lack of harmonization in laboratory reference intervals, particularly for the pediatric population. Furthermore, the observed variation in reference intervals across instruments cannot be explained by the bias between the results obtained on instruments by different manufacturers. Copyright © 2017 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
Empirical Reference Distributions for Networks of Different Size
Smith, Anna; Calder, Catherine A.; Browning, Christopher R.
2016-01-01
Network analysis has become an increasingly prevalent research tool across a vast range of scientific fields. Here, we focus on the particular issue of comparing network statistics, i.e. graph-level measures of network structural features, across multiple networks that differ in size. Although “normalized” versions of some network statistics exist, we demonstrate via simulation why direct comparison is often inappropriate. We consider normalizing network statistics relative to a simple fully parameterized reference distribution and demonstrate via simulation how this is an improvement over direct comparison, but still sometimes problematic. We propose a new adjustment method based on a reference distribution constructed as a mixture model of random graphs which reflect the dependence structure exhibited in the observed networks. We show that using simple Bernoulli models as mixture components in this reference distribution can provide adjusted network statistics that are relatively comparable across different network sizes but still describe interesting features of networks, and that this can be accomplished at relatively low computational expense. Finally, we apply this methodology to a collection of ecological networks derived from the Los Angeles Family and Neighborhood Survey activity location data. PMID:27721556
Computer Graphics Simulations of Sampling Distributions.
ERIC Educational Resources Information Center
Gordon, Florence S.; Gordon, Sheldon P.
1989-01-01
Describes the use of computer graphics simulations to enhance student understanding of sampling distributions that arise in introductory statistics. Highlights include the distribution of sample proportions, the distribution of the difference of sample means, the distribution of the difference of sample proportions, and the distribution of sample…
A Distributed Simulation Software System for Multi-Spacecraft Missions
NASA Technical Reports Server (NTRS)
Burns, Richard; Davis, George; Cary, Everett
2003-01-01
The paper will provide an overview of the web-based distributed simulation software system developed for end-to-end, multi-spacecraft mission design, analysis, and test at the NASA Goddard Space Flight Center (GSFC). This software system was developed for an internal research and development (IR&D) activity at GSFC called the Distributed Space Systems (DSS) Distributed Synthesis Environment (DSE). The long-term goal of the DSS-DSE is to integrate existing GSFC stand-alone test beds, models, and simulation systems to create a "hands on", end-to-end simulation environment for mission design, trade studies and simulations. The short-term goal of the DSE was therefore to develop the system architecture, and then to prototype the core software simulation capability based on a distributed computing approach, with demonstrations of some key capabilities by the end of Fiscal Year 2002 (FY02). To achieve the DSS-DSE IR&D objective, the team adopted a reference model and mission upon which FY02 capabilities were developed. The software was prototyped according to the reference model, and demonstrations were conducted for the reference mission to validate interfaces, concepts, etc. The reference model, illustrated in Fig. 1, included both space and ground elements, with functional capabilities such as spacecraft dynamics and control, science data collection, space-to-space and space-to-ground communications, mission operations, science operations, and data processing, archival and distribution addressed.
Matthews, A P; Garenne, M L
2013-09-01
The matching algorithm in a dynamic marriage market model is described in this first of two companion papers. Iterative Proportional Fitting is used to find a marriage function (an age distribution of new marriages for both sexes), in a stable reference population, that is consistent with the one-sex age distributions of new marriages, and includes age preference. The one-sex age distributions (which are the marginals of the two-sex distribution) are based on the Picrate model, and age preference on a normal distribution, both of which may be adjusted by choice of parameter values. For a population that is perturbed from the reference state, the total number of new marriages is found as the harmonic mean of target totals for men and women obtained by applying reference population marriage rates to the perturbed population. The marriage function uses the age preference function, assumed to be the same for the reference and the perturbed populations, to distribute the total number of new marriages. The marriage function also has an availability factor that varies as the population changes with time, where availability depends on the supply of unmarried men and women. To simplify exposition, only first marriage is treated, and the algorithm is illustrated by application to Zambia. In the second paper, remarriage and dissolution are included. Copyright © 2013 Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Littlefield, R.J.
1990-02-01
To implement an efficient data-parallel program on a non-shared memory MIMD multicomputer, data and computations must be properly partitioned to achieve good load balance and locality of reference. Programs with irregular data reference patterns often require irregular partitions. Although good partitions may be easy to determine, they can be difficult or impossible to implement in programming languages that provide only regular data distributions, such as blocked or cyclic arrays. We are developing Onyx, a programming system that provides a shared memory model of distributed data structures and extends the concept of data distribution to include irregular and dynamic distributions. Thismore » provides a powerful means to specify irregular partitions. Perhaps surprisingly, programs using it can also execute efficiently. In this paper, we describe and evaluate the Onyx implementation of a model problem that repeatedly executes an irregular but fixed data reference pattern. On an NCUBE hypercube, the speed of the Onyx implementation is comparable to that of carefully handwritten message-passing code.« less
de Wilde, J A; Dekker, M; Middelkoop, B J C
2018-03-01
South Asians are prone to cardiometabolic disease at lower BMI levels than most other ethnic groups, starting in childhood. The magnitude of BMI misclassifications is unknown. To compare the BMI distribution of contemporary South Asian 0-20 year olds in the Netherlands with: (1) The South Asian norm reference (secular trends); and (2) The WHO child growth standard and reference. The BMI-for-age distribution of 6677 routine measurements of 3322 South Asian children, aged 0-20 years, was described with the LMS method and BMI z-scores. The BMI distribution in South Asian 0-4 year olds was almost similar to the norm reference (mean BMI z-score = 0.11, skewness = 0.31, SD = 1.0), whereas in 5-19 year olds the distribution had shifted upwards (mean = 0.53) and widened (skewness = -0.12, SD = 1.08). Overweight (incl. obesity) and obesity peaked at 8-10 years, at 45-48% and 35-37%, respectively. Relative to the WHO references, the BMI distribution was left-shifted at ages 0-4 years (mean BMI z-score = -0.46, skewness = 0.23, SD = 0.98) and widened at ages 5-20 years (mean = 0.05; skewness = -0.02, SD = 1.40). At most ages, thinness rates were significantly higher and obesity rates lower than based on South Asian norms. A secular change of BMI-for-age in South Asian children mostly affected children >4 years. WHO references likely under-estimate overweight and obesity rates in South Asian children.
Neghab, Masoud; Jalilian, Hamed; Taheri, Shekoufeh; Tatar, Mohsen; Haji Zadeh, Zeynab
2018-06-01
This study was undertaken to ascertain whether light occupational exposure to pesticides by retailers might be associated with any liver, kidney, nervous system dysfunction or hematological abnormalities. In this cross-sectional study, 70 male pesticide retailers (cases) and 64 male subjects, randomly selected from the constructions workers of city council contractors, as the referent group, were investigated. Urine and blood samples were taken from all subjects for urine analysis, hematological and biochemical parameters. Data analysis was conducted through SPSS v.19 using t-test and chi-square test. The results of urine analysis showed that the frequency of abnormal urine tests was significantly higher in cases than in referent individuals. Similarly, the results of CBC showed that the mean values of monocyte, hemoglobin, hematocrit, mean corpuscular volume, mean corpuscular hemoglobin and platelet distribution width were significantly lower, and mean corpuscular hemoglobin concentration and red blood cell distribution width were significantly higher in retailers. No significant differences were found for other parameters. These findings indicate that an association exists between exposure to pesticides by retailers and early subtle and sub-clinical changes in the urine tests and hematological parameters. Engineering measures are recommended to eliminate exposure to pesticides and to prevent its associated outcomes. Copyright © 2018 Elsevier Inc. All rights reserved.
Elías-Gutiérrez, Manuel; Valdez-Moreno, Martha; Topan, Janet; Young, Monica R; Cohuo-Colli, José Angel
2018-03-01
Currently, freshwater zooplankton sampling and identification methodologies have remained virtually unchanged since they were first established in the beginning of the XX century. One major contributing factor to this slow progress is the limited success of modern genetic methodologies, such as DNA barcoding, in several of the main groups. This study demonstrates improved protocols which enable the rapid assessment of most animal taxa inhabiting any freshwater system by combining the use of light traps, careful fixation at low temperatures using ethanol, and zooplankton-specific primers. We DNA-barcoded 2,136 specimens from a diverse array of taxonomic assemblages (rotifers, mollusks, mites, crustaceans, insects, and fishes) from several Canadian and Mexican lakes with an average sequence success rate of 85.3%. In total, 325 Barcode Index Numbers (BINs) were detected with only three BINs (two cladocerans and one copepod) shared between Canada and Mexico, suggesting a much narrower distribution range of freshwater zooplankton than previously thought. This study is the first to broadly explore the metazoan biodiversity of freshwater systems with DNA barcodes to construct a reference library that represents the first step for future programs which aim to monitor ecosystem health, track invasive species, or improve knowledge of the ecology and distribution of freshwater zooplankton.
Cryogenic thermometry for refrigerant distribution system of JT-60SA
NASA Astrophysics Data System (ADS)
Natsume, K.; Murakami, H.; Kizu, K.; Yoshida, K.; Koide, Y.
2015-12-01
JT-60SA is a fully superconducting fusion experimental device involving Japan and Europe. The cryogenic system supplies supercritical or gaseous helium to superconducting coils through valve boxes or coil terminal boxes and in-cryostat pipes. There are 86 temperature measurement points at 4 K along the distribution line. Resistance temperature sensors will be installed on cooling pipes in vacuum. In this work, two sensor attachment methods, two types of sensor, two thermal anchoring methods, and two sensor fixation materials have been experimentally evaluated in terms of accuracy and mass productivity. Finally, the verification test of thermometry has been conducted using the sample pipe fabricated in the same way to the production version, which has been decided by the comparison experiments. The TVO sensor is attached by the saddle method with Apiezon N grease and the measurement wires made of phosphor bronze are wound on the pipe with Stycast 2850FT as the thermal anchoring. A Cernox sensor is directly immersed in liquid helium as a reference thermometer during the experiment. The measured temperature difference between the attached one and reference one has been within ±15 mK in the range of 3.40-4.73 K. It has satisfies the accuracy requirement of 0.1 K.
Robustness of methods for blinded sample size re-estimation with overdispersed count data.
Schneider, Simon; Schmidli, Heinz; Friede, Tim
2013-09-20
Counts of events are increasingly common as primary endpoints in randomized clinical trials. With between-patient heterogeneity leading to variances in excess of the mean (referred to as overdispersion), statistical models reflecting this heterogeneity by mixtures of Poisson distributions are frequently employed. Sample size calculation in the planning of such trials requires knowledge on the nuisance parameters, that is, the control (or overall) event rate and the overdispersion parameter. Usually, there is only little prior knowledge regarding these parameters in the design phase resulting in considerable uncertainty regarding the sample size. In this situation internal pilot studies have been found very useful and very recently several blinded procedures for sample size re-estimation have been proposed for overdispersed count data, one of which is based on an EM-algorithm. In this paper we investigate the EM-algorithm based procedure with respect to aspects of their implementation by studying the algorithm's dependence on the choice of convergence criterion and find that the procedure is sensitive to the choice of the stopping criterion in scenarios relevant to clinical practice. We also compare the EM-based procedure to other competing procedures regarding their operating characteristics such as sample size distribution and power. Furthermore, the robustness of these procedures to deviations from the model assumptions is explored. We find that some of the procedures are robust to at least moderate deviations. The results are illustrated using data from the US National Heart, Lung and Blood Institute sponsored Asymptomatic Cardiac Ischemia Pilot study. Copyright © 2013 John Wiley & Sons, Ltd.
[Saarland Growth Study: sampling design].
Danker-Hopfe, H; Zabransky, S
2000-01-01
The use of reference data to evaluate the physical development of children and adolescents is part of the daily routine in the paediatric ambulance. The construction of such reference data is based on the collection of extensive reference data. There are different kinds of reference data: cross sectional references, which are based on data collected from a big representative cross-sectional sample of the population, longitudinal references, which are based on follow-up surveys of usually smaller samples of individuals from birth to maturity, and mixed longitudinal references, which are a combination of longitudinal and cross-sectional reference data. The advantages and disadvantages of the different methods of data collection and the resulting reference data are discussed. The Saarland Growth Study was conducted for several reasons: growth processes are subject to secular changes, there are no specific reference data for children and adolescents from this part of the country and the growth charts in use in the paediatric praxis are possibly not appropriate any more. Therefore, the Saarland Growth Study served two purposes a) to create actual regional reference data and b) to create a database for future studies on secular trends in growth processes of children and adolescents from Saarland. The present contribution focusses on general remarks on the sampling design of (cross-sectional) growth surveys and its inferences for the design of the present study.
Method and Apparatus for Measuring Near-Angle Scattering of Mirror Coatings
NASA Technical Reports Server (NTRS)
Chipman, Russell A. (Inventor); Daugherty, Brian J. (Inventor); McClain, Stephen C. (Inventor); Macenka, Steven A. (Inventor)
2013-01-01
Disclosed herein is a method of determining the near angle scattering of a sample reflective surface comprising the steps of: a) splitting a beam of light having a coherence length of greater than or equal to about 2 meters into a sample beam and a reference beam; b) frequency shifting both the sample beam and the reference beam to produce a fixed beat frequency between the sample beam and the reference beam; c) directing the sample beam through a focusing lens and onto the sample reflective surface, d) reflecting the sample beam from the sample reflective surface through a detection restriction disposed on a movable stage; e) recombining the sample beam with the reference beam to form a recombined beam, followed by f) directing the recombined beam to a detector and performing heterodyne analysis on the recombined beam to measure the near-angle scattering of the sample reflective surface, wherein the position of the detection restriction relative to the sample beam is varied to occlude at least a portion of the sample beam to measure the near-angle scattering of the sample reflective surface. An apparatus according to the above method is also disclosed.
Developing a Hypothetical Learning Trajectory for the Sampling Distribution of the Sample Means
NASA Astrophysics Data System (ADS)
Syafriandi
2018-04-01
Special types of probability distribution are sampling distributions that are important in hypothesis testing. The concept of a sampling distribution may well be the key concept in understanding how inferential procedures work. In this paper, we will design a hypothetical learning trajectory (HLT) for the sampling distribution of the sample mean, and we will discuss how the sampling distribution is used in hypothesis testing.
Irei, Satoshi
2016-01-01
Molecular marker analysis of environmental samples often requires time consuming preseparation steps. Here, analysis of low-volatile nonpolar molecular markers (5-6 ring polycyclic aromatic hydrocarbons or PAHs, hopanoids, and n-alkanes) without the preseparation procedure is presented. Analysis of artificial sample extracts was directly conducted by gas chromatography-mass spectrometry (GC-MS). After every sample injection, a standard mixture was also analyzed to make a correction on the variation of instrumental sensitivity caused by the unfavorable matrix contained in the extract. The method was further validated for the PAHs using the NIST standard reference materials (SRMs) and then applied to airborne particulate matter samples. Tests with the SRMs showed that overall our methodology was validated with the uncertainty of ~30%. The measurement results of airborne particulate matter (PM) filter samples showed a strong correlation between the PAHs, implying the contributions from the same emission source. Analysis of size-segregated PM filter samples showed that their size distributions were found to be in the PM smaller than 0.4 μm aerodynamic diameter. The observations were consistent with our expectation of their possible sources. Thus, the method was found to be useful for molecular marker studies. PMID:27127511
NASA Astrophysics Data System (ADS)
Gozzard, David R.; Schediwy, Sascha W.; Dodson, Richard; Rioja, María J.; Hill, Mike; Lennon, Brett; McFee, Jock; Mirtschin, Peter; Stevens, Jamie; Grainge, Keith
2017-07-01
In order to meet its cutting-edge scientific objectives, the Square Kilometre Array (SKA) telescope requires high-precision frequency references to be distributed to each of its antennas. The frequency references are distributed via fiber-optic links and must be actively stabilized to compensate for phase noise imposed on the signals by environmental perturbations on the links. SKA engineering requirements demand that any proposed frequency reference distribution system be proved in “astronomical verification” tests. We present results of the astronomical verification of a stabilized frequency reference transfer system proposed for SKA-mid. The dual-receiver architecture of the Australia Telescope Compact Array was exploited to subtract the phase noise of the sky signal from the data, allowing the phase noise of observations performed using a standard frequency reference, as well as the stabilized frequency reference transfer system transmitting over 77 km of fiber-optic cable, to be directly compared. Results are presented for the fractional frequency stability and phase drift of the stabilized frequency reference transfer system for celestial calibrator observations at 5 and 25 GHz. These observations plus additional laboratory results for the transferred signal stability over a 166 km metropolitan fiber-optic link are used to show that the stabilized transfer system under test exceeds all SKA phase-stability requirements within a broad range of observing conditions. Furthermore, we have shown that alternative reference dissemination systems that use multiple synthesizers to supply reference signals to sub-sections of an array may limit the imaging capability of the telescope.
Understanding the Sampling Distribution and the Central Limit Theorem.
ERIC Educational Resources Information Center
Lewis, Charla P.
The sampling distribution is a common source of misuse and misunderstanding in the study of statistics. The sampling distribution, underlying distribution, and the Central Limit Theorem are all interconnected in defining and explaining the proper use of the sampling distribution of various statistics. The sampling distribution of a statistic is…
Gaeuman, David; Andrews, E.D.; Krause, Andreas; Smith, Wes
2009-01-01
Bed load samples from four locations in the Trinity River of northern California are analyzed to evaluate the performance of the Wilcock‐Crowe bed load transport equations for predicting fractional bed load transport rates. Bed surface particles become smaller and the fraction of sand on the bed increases with distance downstream from Lewiston Dam. The dimensionless reference shear stress for the mean bed particle size (τ*rm) is largest near the dam, but varies relatively little between the more downstream locations. The relation between τ*rm and the reference shear stresses for other size fractions is constant across all locations. Total bed load transport rates predicted with the Wilcock‐Crowe equations are within a factor of 2 of sampled transport rates for 68% of all samples. The Wilcock‐Crowe equations nonetheless consistently under‐predict the transport of particles larger than 128 mm, frequently by more than an order of magnitude. Accurate prediction of the transport rates of the largest particles is important for models in which the evolution of the surface grain size distribution determines subsequent bed load transport rates. Values of τ*rm estimated from bed load samples are up to 50% larger than those predicted with the Wilcock‐Crowe equations, and sampled bed load transport approximates equal mobility across a wider range of grain sizes than is implied by the equations. Modifications to the Wilcock‐Crowe equation for determining τ*rm and the hiding function used to scale τ*rm to other grain size fractions are proposed to achieve the best fit to observed bed load transport in the Trinity River.
Robotic Mars Sample Return: Risk Assessment and Analysis Report
NASA Technical Reports Server (NTRS)
Lalk, Thomas R.; Spence, Cliff A.
2003-01-01
A comparison of the risk associated with two alternative scenarios for a robotic Mars sample return mission was conducted. Two alternative mission scenarios were identified, the Jet Propulsion Lab (JPL) reference Mission and a mission proposed by Johnson Space Center (JSC). The JPL mission was characterized by two landers and an orbiter, and a Mars orbit rendezvous to retrieve the samples. The JSC mission (Direct/SEP) involves a solar electric propulsion (SEP) return to earth followed by a rendezvous with the space shuttle in earth orbit. A qualitative risk assessment to identify and characterize the risks, and a risk analysis to quantify the risks were conducted on these missions. Technical descriptions of the competing scenarios were developed in conjunction with NASA engineers and the sequence of events for each candidate mission was developed. Risk distributions associated with individual and combinations of events were consolidated using event tree analysis in conjunction with Monte Carlo techniques to develop probabilities of mission success for each of the various alternatives. The results were the probability of success of various end states for each candidate scenario. These end states ranged from complete success through various levels of partial success to complete failure. Overall probability of success for the Direct/SEP mission was determined to be 66% for the return of at least one sample and 58% for the JPL mission for the return of at least one sample cache. Values were also determined for intermediate events and end states as well as for the probability of violation of planetary protection. Overall mission planetary protection event probabilities of occurrence were determined to be 0.002% and 1.3% for the Direct/SEP and JPL Reference missions respectively.
Systematic review and consensus guidelines for environmental sampling of Burkholderia pseudomallei.
Limmathurotsakul, Direk; Dance, David A B; Wuthiekanun, Vanaporn; Kaestli, Mirjam; Mayo, Mark; Warner, Jeffrey; Wagner, David M; Tuanyok, Apichai; Wertheim, Heiman; Yoke Cheng, Tan; Mukhopadhyay, Chiranjay; Puthucheary, Savithiri; Day, Nicholas P J; Steinmetz, Ivo; Currie, Bart J; Peacock, Sharon J
2013-01-01
Burkholderia pseudomallei, a Tier 1 Select Agent and the cause of melioidosis, is a Gram-negative bacillus present in the environment in many tropical countries. Defining the global pattern of B. pseudomallei distribution underpins efforts to prevent infection, and is dependent upon robust environmental sampling methodology. Our objective was to review the literature on the detection of environmental B. pseudomallei, update the risk map for melioidosis, and propose international consensus guidelines for soil sampling. An international working party (Detection of Environmental Burkholderia pseudomallei Working Party (DEBWorP)) was formed during the VIth World Melioidosis Congress in 2010. PubMed (January 1912 to December 2011) was searched using the following MeSH terms: pseudomallei or melioidosis. Bibliographies were hand-searched for secondary references. The reported geographical distribution of B. pseudomallei in the environment was mapped and categorized as definite, probable, or possible. The methodology used for detecting environmental B. pseudomallei was extracted and collated. We found that global coverage was patchy, with a lack of studies in many areas where melioidosis is suspected to occur. The sampling strategies and bacterial identification methods used were highly variable, and not all were robust. We developed consensus guidelines with the goals of reducing the probability of false-negative results, and the provision of affordable and 'low-tech' methodology that is applicable in both developed and developing countries. The proposed consensus guidelines provide the basis for the development of an accurate and comprehensive global map of environmental B. pseudomallei.
Effects of sample size on KERNEL home range estimates
Seaman, D.E.; Millspaugh, J.J.; Kernohan, Brian J.; Brundige, Gary C.; Raedeke, Kenneth J.; Gitzen, Robert A.
1999-01-01
Kernel methods for estimating home range are being used increasingly in wildlife research, but the effect of sample size on their accuracy is not known. We used computer simulations of 10-200 points/home range and compared accuracy of home range estimates produced by fixed and adaptive kernels with the reference (REF) and least-squares cross-validation (LSCV) methods for determining the amount of smoothing. Simulated home ranges varied from simple to complex shapes created by mixing bivariate normal distributions. We used the size of the 95% home range area and the relative mean squared error of the surface fit to assess the accuracy of the kernel home range estimates. For both measures, the bias and variance approached an asymptote at about 50 observations/home range. The fixed kernel with smoothing selected by LSCV provided the least-biased estimates of the 95% home range area. All kernel methods produced similar surface fit for most simulations, but the fixed kernel with LSCV had the lowest frequency and magnitude of very poor estimates. We reviewed 101 papers published in The Journal of Wildlife Management (JWM) between 1980 and 1997 that estimated animal home ranges. A minority of these papers used nonparametric utilization distribution (UD) estimators, and most did not adequately report sample sizes. We recommend that home range studies using kernel estimates use LSCV to determine the amount of smoothing, obtain a minimum of 30 observations per animal (but preferably a?Y50), and report sample sizes in published results.
2018-01-01
Numerous bacterial genetic markers are available for the molecular detection of human sources of fecal pollution in environmental waters. However, widespread application is hindered by a lack of knowledge regarding geographical stability, limiting implementation to a small number of well-characterized regions. This study investigates the geographic distribution of five human-associated genetic markers (HF183/BFDrev, HF183/BacR287, BacHum-UCD, BacH, and Lachno2) in municipal wastewaters (raw and treated) from 29 urban and rural wastewater treatment plants (750–4 400 000 population equivalents) from 13 countries spanning six continents. In addition, genetic markers were tested against 280 human and nonhuman fecal samples from domesticated, agricultural and wild animal sources. Findings revealed that all genetic markers are present in consistently high concentrations in raw (median log10 7.2–8.0 marker equivalents (ME) 100 mL–1) and biologically treated wastewater samples (median log10 4.6–6.0 ME 100 mL–1) regardless of location and population. The false positive rates of the various markers in nonhuman fecal samples ranged from 5% to 47%. Results suggest that several genetic markers have considerable potential for measuring human-associated contamination in polluted environmental waters. This will be helpful in water quality monitoring, pollution modeling and health risk assessment (as demonstrated by QMRAcatch) to guide target-oriented water safety management across the globe. PMID:29570973
Böhlke, J.K.; Mroczkowski, S.J.; Coplen, T.B.
2003-01-01
Despite a rapidly growing literature on analytical methods and field applications of O isotope-ratio measurements of NO3− in environmental studies, there is evidence that the reported data may not be comparable because reference materials with widely varying δ18O values have not been readily available. To address this problem, we prepared large quantities of two nitrate salts with contrasting O isotopic compositions for distribution as reference materials for O isotope-ratio measurements: USGS34 (KNO3) with low δ18O and USGS35 (NaNO3) with high δ18O and ‘mass-independent’ δ17O. The procedure used to produce USGS34 involved equilibration of HNO3 with 18O-depleted meteoric water. Nitric acid equilibration is proposed as a simple method for producing laboratory NO3− reference materials with a range of δ18O values and normal (mass-dependent) 18O:17O:16O variation. Preliminary data indicate that the equilibrium O isotope-fractionation factor (α) between [NO3−] and H2O decreases with increasing temperature from 1.0215 at 22°C to 1.0131 at 100°C. USGS35 was purified from the nitrate ore deposits of the Atacama Desert in Chile and has a high 17O:18O ratio owing to its atmospheric origin. These new reference materials, combined with previously distributed NO3− isotopic reference materials IAEA-N3 (=IAEA-NO-3) and USGS32, can be used to calibrate local laboratory reference materials for determining offset values, scale factors, and mass-independent effects on N and O isotope-ratio measurements in a wide variety of environmental NO3− samples. Preliminary analyses yield the following results (normalized with respect to VSMOW and SLAP, with reproducibilities of ±0.2–0.3‰, 1σ): IAEA-N3 has δ18O = +25.6‰ and δ17O = +13.2‰; USGS32 has δ18O = +25.7‰; USGS34 has δ18O = −27.9‰ and δ17O = −14.8‰; and USGS35 has δ18O = +57.5‰ and δ17O = +51.5‰.
Evaluation of Skin Surface as an Alternative Source of Reference DNA Samples: A Pilot Study.
Albujja, Mohammed H; Bin Dukhyil, Abdul Aziz; Chaudhary, Abdul Rauf; Kassab, Ahmed Ch; Refaat, Ahmed M; Babu, Saranya Ramesh; Okla, Mohammad K; Kumar, Sachil
2018-01-01
An acceptable area for collecting DNA reference sample is a part of the forensic DNA analysis development. The aim of this study was to evaluate skin surface cells (SSC) as an alternate source of reference DNA sample. From each volunteer (n = 10), six samples from skin surface areas (forearm and fingertips) and two traditional samples (blood and buccal cells) were collected. Genomic DNA was extracted and quantified then genotyped using standard techniques. The highest DNA concentration of SSC samples was collected using the tape/forearm method of collection (2.1 ng/μL). Cotton swabs moistened with ethanol yielded higher quantities of DNA than swabs moistened with salicylic acid, and it gave the highest percentage of full STR profiles (97%). This study supports the use of SSC as a noninvasive sampling technique and as a extremely useful source of DNA reference samples among certain cultures where the use of buccal swabs can be considered socially unacceptable. © 2017 American Academy of Forensic Sciences.
Distribution-centric 3-parameter thermodynamic models of partition gas chromatography.
Blumberg, Leonid M
2017-03-31
If both parameters (the entropy, ΔS, and the enthalpy, ΔH) of the classic van't Hoff model of dependence of distribution coefficients (K) of analytes on temperature (T) are treated as the temperature-independent constants then the accuracy of the model is known to be insufficient for the needed accuracy of retention time prediction. A more accurate 3-parameter Clarke-Glew model offers a way to treat ΔS and ΔH as functions, ΔS(T) and ΔH(T), of T. A known T-centric construction of these functions is based on relating them to the reference values (ΔS ref and ΔH ref ) corresponding to a predetermined reference temperature (T ref ). Choosing a single T ref for all analytes in a complex sample or in a large database might lead to practically irrelevant values of ΔS ref and ΔH ref for those analytes that have too small or too large retention factors at T ref . Breaking all analytes in several subsets each with its own T ref leads to discontinuities in the analyte parameters. These problems are avoided in the K-centric modeling where ΔS(T) and ΔS(T) and other analyte parameters are described in relation to their values corresponding to a predetermined reference distribution coefficient (K Ref ) - the same for all analytes. In this report, the mathematics of the K-centric modeling are described and the properties of several types of K-centric parameters are discussed. It has been shown that the earlier introduced characteristic parameters of the analyte-column interaction (the characteristic temperature, T char , and the characteristic thermal constant, θ char ) are a special chromatographically convenient case of the K-centric parameters. Transformations of T-centric parameters into K-centric ones and vice-versa as well as the transformations of one set of K-centric parameters into another set and vice-versa are described. Copyright © 2017 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Vogt, N.; Contreras-Quijada, A.; Fuentes-Morales, I.; Vogt-Geisse, S.; Arcos, C.; Abarca, C.; Agurto-Gangas, C.; Caviedes, M.; DaSilva, H.; Flores, J.; Gotta, V.; Peñaloza, F.; Rojas, K.; Villaseñor, J. I.
2016-11-01
We have developed an interactive PYTHON code and derived crucial ephemeris data of 99.4% of all stars classified as “Mira” in the ASAS database, referring to pulsation periods, mean maximum magnitudes, and whenever possible, the amplitudes among others. We present a statistical comparison between our results and those given by the International Variable Star Index (VSX) of the American Association of Variable Star Observers, as well as those determined with the machine learning automatic procedure of Richards et al. Our periods are in good agreement with those of the VSX in more than 95% of the stars. However, when comparing our periods with those of Richards et al., the coincidence rate is only 76% and most of the remaining cases refer to aliases. We conclude that automatic codes still require more refinements in order to provide reliable period values. Period distributions of the target stars show three local maxima around 215, 275, and 330 days, apparently of universal validity; their relative strength seems to depend on galactic longitude. Our visual amplitude distribution turns out to be bimodal, however, 1/3 of the targets have rather small amplitudes (A < 2.5m) and could refer to semiregular variables (SR). We estimate that about 20% of our targets belong to the SR class. We also provide a list of 63 candidates for period variations and a sample of 35 multiperiodic stars that seem to confirm the universal validity of typical sequences in the double period and in the Petersen diagrams.
Moreano, Francisco; Busch, Ulrich; Engel, Karl-Heinz
2005-12-28
Milling fractions from conventional and transgenic corn were prepared at laboratory scale and used to study the influence of sample composition and heat-induced DNA degradation on the relative quantification of genetically modified organisms (GMO) in food products. Particle size distributions of the obtained fractions (coarse grits, regular grits, meal, and flour) were characterized using a laser diffraction system. The application of two DNA isolation protocols revealed a strong correlation between the degree of comminution of the milling fractions and the DNA yield in the extracts. Mixtures of milling fractions from conventional and transgenic material (1%) were prepared and analyzed via real-time polymerase chain reaction. Accurate quantification of the adjusted GMO content was only possible in mixtures containing conventional and transgenic material in the form of analogous milling fractions, whereas mixtures of fractions exhibiting different particle size distributions delivered significantly over- and underestimated GMO contents depending on their compositions. The process of heat-induced nucleic acid degradation was followed by applying two established quantitative assays showing differences between the lengths of the recombinant and reference target sequences (A, deltal(A) = -25 bp; B, deltal(B) = +16 bp; values related to the amplicon length of the reference gene). Data obtained by the application of method A resulted in underestimated recoveries of GMO contents in the samples of heat-treated products, reflecting the favored degradation of the longer target sequence used for the detection of the transgene. In contrast, data yielded by the application of method B resulted in increasingly overestimated recoveries of GMO contents. The results show how commonly used food technological processes may lead to distortions in the results of quantitative GMO analyses.
Zhang, Guihua; Shinohara, Naohide; Kano, Hirokazu; Senoh, Hideki; Suzuki, Masaaki; Sasaki, Takeshi; Fukushima, Shoji; Gamo, Masashi
2015-06-01
The unevenness of pulmonary nanoparticle (NP) distribution, which hinders the establishment of an absolute dose-response relationship, has been described as one of the limitations of intratracheal administration techniques for toxicological assessment of inhaled NPs. Quantification of the NP microdistribution would facilitate the establishment of a concentration-response relationship in localized regions of the lung; however, such quantitative methods have not been reported. Here, we established a quantitative method for evaluating pulmonary TiO2 NP microdistribution in rats using X-ray fluorescence microscopy. Ti intensity in lung sections from rats intratracheally administered 10 mg kg(-1) TiO2 NPs with a microsprayer was measured using X-ray fluorescence with a 100 µm beam size. Ti reference samples were prepared by dropping different concentrations of Ti solutions on glass slide or lung sections of untreated rat. Ti intensity increased linearly with Ti content in the reference samples on both substrates. The detection limit of TiO2 was estimated to be 6.3 ng mm(-2) . The reproducibility was confirmed for measurements done in the short- (2 weeks) and long-term (6 months). The quantitative results of TiO2 NP microdistribution suggested that more TiO2 NPs were distributed in the right caudal and accessory lobes, which are located downstream of the administration direction of the NP suspension, and the lower portion of each lobe. The detection rates of TiO2 NPs were 16.6-25.0%, 5.19-15.6%, 28.6-39.2%, 21.4-38.7% and 10.6-23.2% for lung sections from the right cranial, middle, caudal, accessory and left lobes, respectively. Copyright © 2015 John Wiley & Sons, Ltd.
Khan, Rishi L; Gonye, Gregory E; Gao, Guang; Schwaber, James S
2006-01-01
Background Using microarrays by co-hybridizing two samples labeled with different dyes enables differential gene expression measurements and comparisons across slides while controlling for within-slide variability. Typically one dye produces weaker signal intensities than the other often causing signals to be undetectable. In addition, undetectable spots represent a large problem for two-color microarray designs and most arrays contain at least 40% undetectable spots even when labeled with reference samples such as Stratagene's Universal Reference RNAs™. Results We introduce a novel universal reference sample that produces strong signal for all spots on the array, increasing the average fraction of detectable spots to 97%. Maximizing detectable spots on the reference image channel also decreases the variability of microarray data allowing for reliable detection of smaller differential gene expression changes. The reference sample is derived from sequence contained in the parental EST clone vector pT7T3D-Pac and is called vector RNA (vRNA). We show that vRNA can also be used for quality control of microarray printing and PCR product quality, detection of hybridization anomalies, and simplification of spot finding and segmentation tasks. This reference sample can be made inexpensively in large quantities as a renewable resource that is consistent across experiments. Conclusion Results of this study show that vRNA provides a useful universal reference that yields high signal for almost all spots on a microarray, reduces variation and allows for comparisons between experiments and laboratories. Further, it can be used for quality control of microarray printing and PCR product quality, detection of hybridization anomalies, and simplification of spot finding and segmentation tasks. This type of reference allows for detection of small changes in differential expression while reference designs in general allow for large-scale multivariate experimental designs. vRNA in combination with reference designs enable systems biology microarray experiments of small physiologically relevant changes. PMID:16677381
The Potential for Spatial Distribution Indices to Signal Thresholds in Marine Fish Biomass
Reuchlin-Hugenholtz, Emilie
2015-01-01
The frequently observed positive relationship between fish population abundance and spatial distribution suggests that changes in distribution can be indicative of trends in abundance. If contractions in spatial distribution precede declines in spawning stock biomass (SSB), spatial distribution reference points could complement the SSB reference points that are commonly used in marine conservation biology and fisheries management. When relevant spatial distribution information is integrated into fisheries management and recovery plans, risks and uncertainties associated with a plan based solely on the SSB criterion would be reduced. To assess the added value of spatial distribution data, we examine the relationship between SSB and four metrics of spatial distribution intended to reflect changes in population range, concentration, and density for 10 demersal populations (9 species) inhabiting the Scotian Shelf, Northwest Atlantic. Our primary purpose is to assess their potential to serve as indices of SSB, using fisheries independent survey data. We find that metrics of density offer the best correlate of spawner biomass. A decline in the frequency of encountering high density areas is associated with, and in a few cases preceded by, rapid declines in SSB in 6 of 10 populations. Density-based indices have considerable potential to serve both as an indicator of SSB and as spatially based reference points in fisheries management. PMID:25789624
Inter-laboratory comparison measurements of radiochemical laboratories in Slovakia.
Meresová, J; Belanová, A; Vrsková, M
2010-01-01
The first inter-laboratory comparison organized by the radiochemistry laboratory of Water Research Institute (WRI) in Bratislava was carried out in 1993 and since then is it realized on an annual basis and about 10 radiochemical laboratories from all over Slovakia are participating. The gross alpha and gross beta activities, and the activity concentrations of (222)Rn, tritium, and (226)Ra, and U(nat) concentration in synthetic water samples are compared. The distributed samples are covering the concentration range prevailing in potable and surface waters and are prepared by dilution of certified reference materials. Over the course of the years 1993-2008, we observed the improvement in the quality of results for most of the laboratories. However, the success rate of the gross alpha determination activity is not improving as much as the other parameters. Copyright 2009 Elsevier Ltd. All rights reserved.
Isotopic Composition of Oxygen in Lunar Zircons
NASA Technical Reports Server (NTRS)
Nemchin, A. A.; Whitehouse, M. J.; Pidgeon, R. T.; Meyer, C.
2005-01-01
The recent discovery of heavy oxygen in zircons from the Jack Hills conglomerates Wilde et al. and Mojzsis et al. was interpreted as an indication of presence of liquid water on the surface of Early Earth. The distribution of ages of Jack Hills zircons and lunar zircons appears to be very similar and therefore analysis of oxygen in the lunar grains may provide a reference frame for further study of the early history of the Earth as well as give additional information regarding processes that operated on the Moon. In the present study we have analysed the oxygen isotopic composition of zircon grains from three lunar samples using the Swedish Museum of Natural History CAMECA 1270 ion microprobe. The samples were selected as likely tests for variations in lunar oxygen isotopic composition. Additional information is included in the original extended abstract.
Lin, Zhixiong; Liu, Haiyan; Riniker, Sereina; van Gunsteren, Wilfred F
2011-12-13
Enveloping distribution sampling (EDS) is a powerful method to compute relative free energies from simulation. So far, the EDS method has only been applied to alchemical free energy differences, i.e., between different Hamiltonians defining different systems, and not yet to obtain free energy differences between different conformations or conformational states of a system. In this article, we extend the EDS formalism such that it can be applied to compute free energy differences of different conformations and apply it to compute the relative free enthalpy ΔG of 310-, α-, and π-helices of an alanine deca-peptide in explicit water solvent. The resulting ΔG values are compared to those obtained by standard thermodynamic integration (TI) and from so-called end-state simulations. A TI simulation requires the definition of a λ-dependent pathway which in the present case is based on hydrogen bonds of the different helical conformations. The values of ⟨(∂VTI)/(∂λ)⟩λ show a sharp change for a particular range of λ values, which is indicative of an energy barrier along the pathway, which lowers the accuracy of the resulting ΔG value. In contrast, in a two-state EDS simulation, an unphysical reference-state Hamiltonian which connects the parts of conformational space that are relevant to the different end states is constructed automatically; that is, no pathway needs to be defined. In the simulation using this reference state, both helices were sampled, and many transitions between them occurred, thus ensuring the accuracy of the resulting free enthalpy difference. According to the EDS simulations, the free enthalpy differences of the π-helix and the 310-helix versus the α-helix are 5 kJ mol(-1) and 47 kJ mol(-1), respectively, for an alanine deca-peptide in explicit SPC water solvent using the GROMOS 53A6 force field. The EDS method, which is a particular form of umbrella sampling, is thus applicable to compute free energy differences between conformational states as well as between systems and has definite advantages over the traditional TI and umbrella sampling methods to compute relative free energies.
The FASES instrument development and experiment preparation for the ISS
NASA Astrophysics Data System (ADS)
Picker, Gerold; Gollinger, Klaus; Greger, Ralf; Dettmann, Jan; Winter, Josef; Dewandre, Thierry; Castiglione, Luigi; Vincent-Bonnieu, Sebastien; Liggieri, Libero; Clausse, Daniele; Antoni, Mickael
The FASES experiments target the investigation of the stability of emulsions. The main objec-tives are the study of the surfactant adsorption at the liquid / liquid interfaces, the interaction of the droplets as well as the behaviour of the liquid film between nearby drops. Particular focus is given to the dynamic droplet evolution during emulsion destabilisation. The results of the experiments shall support development of methods for the modelling of droplet size distri-butions, which are important to many industries using stable emulsions like food production, cosmetics and pharmaceutics or unstable emulsions as required for applications in waste water treatment or crude oil recovery. The development of the experimental instrumentation was initiated in 2002. The flight instru-ment hardware development was started in 2004 and finally the flight unit was completed in 2009. Currently the final flight preparation is proceeding targeting a launch to the International Space Station (ISS) with Progress 39P in September 2010. The experiment setup of the instrument is accommodated in a box type insert called Experiment Container (EC), which will be installed in the Fluid Science Laboratory part of the European Columbus module of the ISS. The EC is composed of two diagnostics instruments for the investigation of transparent and opaque liquid emulsion. The transparent emulsions will be subject to the experiment called "Investigations on drop/drop interactions in Transparent Emulsions" (ITEM). The opaque emulsion samples will be studied in the experiment called "Investigations on concentrated or opaque Emulsions and on Phase Inversions" (EMPI). The thermal conditioning unit (TCU) allows performing homogeneous thermalization, tem-perature sweeps, emulsion preparation by stirrer, and optical diagnostics with a scanning mi-croscope. The objective of the instrument is the 3D reconstruction of the emulsion droplet distribution in the liquid matrix in terms of the droplet sizes, location and their time depen-dent evolution. The TCU will be used for the stability experiment ITEM-S and the droplet freezing experiment ITEM-F. The Differential Scanning Calorimeter (DSC) will give an information about the evolution of the emulsion through the droplet size distribution and the dispersion state of the droplets within the emulsion during a controlled temperature sweep by measuring the latent heat of droplet freezing and melting during the EMPI experiments. For this purpose the calorimeter is equipped with a reference sample filled with a pure liquid matrix and a similar measurement sample filled with the specific emulsion under investigation. The differential heat flux between measurement sample and reference sample is measured with a sensitive heat flux sensor. Each instrument is serviced by a robotic sample stowage system, which accommodates in total 44 different ITEM and EMPI emulsion samples each filled with a specific composition of the emulsion. Currently the flight preparation is ongoing with particular focus on the preparation of the emulsion flight sample set and the instrument's operating parameters. The FASES flight instrument was developed by ASTRIUM Space Transportation Germany with support of RUAG Aerospace Wallisellen under ESA / ESTEC contract. The science team of FASES is supported by ESA/ESTEC (Microgravity Application Programme, AO99-052).
Apparatus and method for detecting gamma radiation
Sigg, Raymond A.
1994-01-01
A high efficiency radiation detector for measuring X-ray and gamma radiation from small-volume, low-activity liquid samples with an overall uncertainty better than 0.7% (one sigma SD). The radiation detector includes a hyperpure germanium well detector, a collimator, and a reference source. The well detector monitors gamma radiation emitted by the reference source and a radioactive isotope or isotopes in a sample source. The radiation from the reference source is collimated to avoid attenuation of reference source gamma radiation by the sample. Signals from the well detector are processed and stored, and the stored data is analyzed to determine the radioactive isotope(s) content of the sample. Minor self-attenuation corrections are calculated from chemical composition data.
Extreme-value statistics of fractional Brownian motion bridges.
Delorme, Mathieu; Wiese, Kay Jörg
2016-11-01
Fractional Brownian motion is a self-affine, non-Markovian, and translationally invariant generalization of Brownian motion, depending on the Hurst exponent H. Here we investigate fractional Brownian motion where both the starting and the end point are zero, commonly referred to as bridge processes. Observables are the time t_{+} the process is positive, the maximum m it achieves, and the time t_{max} when this maximum is taken. Using a perturbative expansion around Brownian motion (H=1/2), we give the first-order result for the probability distribution of these three variables and the joint distribution of m and t_{max}. Our analytical results are tested and found to be in excellent agreement, with extensive numerical simulations for both H>1/2 and H<1/2. This precision is achieved by sampling processes with a free end point and then converting each realization to a bridge process, in generalization to what is usually done for Brownian motion.
[Image fusion: use in the control of the distribution of prostatic biopsies].
Mozer, Pierre; Baumann, Michaël; Chevreau, Grégoire; Troccaz, Jocelyne
2008-02-01
Prostate biopsies are performed under 2D TransRectal UltraSound (US) guidance by sampling the prostate according to a predefined pattern. Modern image processing tools allow better control of biopsy distribution. We evaluated the accuracy of a single operator performing a pattern of 12 ultrasound-guided biopsies by registering 3D ultrasound control images acquired after each biopsy. For each patient, prostate image alignment was performed automatically with a voxel-based registration algorithm allowing visualization of each biopsy trajectory in a single ultrasound reference volume. On average, the operator reached the target in 60% of all cases. This study shows that it is difficult to accurately reach targets in the prostate using 2D ultrasound. In the near future, real-time fusion of MRI and US images will allow selection of a target in previously acquired MR images and biopsy of this target by US guidance.
Distributed Capacitive Sensor for Sample Mass Measurement
NASA Technical Reports Server (NTRS)
Toda, Risaku; McKinney, Colin; Jackson, Shannon P.; Mojarradi, Mohammad; Manohara, Harish; Trebi-Ollennu, Ashitey
2011-01-01
Previous robotic sample return missions lacked in situ sample verification/ quantity measurement instruments. Therefore, the outcome of the mission remained unclear until spacecraft return. In situ sample verification systems such as this Distributed Capacitive (DisC) sensor would enable an unmanned spacecraft system to re-attempt the sample acquisition procedures until the capture of desired sample quantity is positively confirmed, thereby maximizing the prospect for scientific reward. The DisC device contains a 10-cm-diameter pressure-sensitive elastic membrane placed at the bottom of a sample canister. The membrane deforms under the weight of accumulating planetary sample. The membrane is positioned in close proximity to an opposing rigid substrate with a narrow gap. The deformation of the membrane makes the gap narrower, resulting in increased capacitance between the two parallel plates (elastic membrane and rigid substrate). C-V conversion circuits on a nearby PCB (printed circuit board) provide capacitance readout via LVDS (low-voltage differential signaling) interface. The capacitance method was chosen over other potential approaches such as the piezoelectric method because of its inherent temperature stability advantage. A reference capacitor and temperature sensor are embedded in the system to compensate for temperature effects. The pressure-sensitive membranes are aluminum 6061, stainless steel (SUS) 403, and metal-coated polyimide plates. The thicknesses of these membranes range from 250 to 500 m. The rigid substrate is made with a 1- to 2-mm-thick wafer of one of the following materials depending on the application requirements glass, silicon, polyimide, PCB substrate. The glass substrate is fabricated by a microelectromechanical systems (MEMS) fabrication approach. Several concentric electrode patterns are printed on the substrate. The initial gap between the two plates, 100 m, is defined by a silicon spacer ring that is anodically bonded to the glass substrate. The fabricated proof-of-concept devices have successfully demonstrated tens to hundreds of picofarads of capacitance change when a simulated sample (100 g to 500 g) is placed on the membrane.
Reference samples for the earth sciences
Flanagan, F.J.
1974-01-01
A revised list of reference samples of interest to geoscientists has been extended to include samples for the agronomist, the archaeologist and the environmentalist. In addition to the source from which standard samples may be obtained, references or pertinent notes for some samples are included. The number of rock reference samples is now almost adequate, and the variety of ore samples will soon be sufficient. There are very few samples for microprobe work. Oil shales will become more important because of the outlook for world petroleum resources. The dryland equivalent of a submarine basalt might be useful in studies of sea-floor spreading and of the geochemistry of basalts. The Na- and K-feldspars of BCS (British Chemical Standards-Bureau of Analysed Samples), NBS (National Bureau of Standards), and ANRT (Association Kationale de la Recherche Technique) could serve as trace-element standards if such data were available. Similarly, the present NBS flint and plastic clays, as well as their predecessors, might be useful for archaeological pottery studies. The International Decade for Ocean Exploration may stimulate the preparation of ocean-water standards for trace elements or pollutants and a standard for manganese nodules. ?? 1974.
Tofanelli, Sergio; Taglioli, Luca; Varesi, Laurent; Paoli, Giorgio
2004-04-01
To genetically reconstruct the demographic history of the human population of Corsica (western Mediterranean), we analyzed the variability at eight autosomal STR loci (FES, VWA, CSF1PO, TH01, F13A1, TPOX, CD4, and D3S1358) in a sample of 179 native blood donors from 4 out of the 5 administrative districts. The main line of genetic discontinuity inferred from the spatial distribution of STR variability overlapped the linguistic and geographic boundaries. In the innermost areas (Corte district) several estimators had larger stochastic effects on allele frequencies. Genetic distance measures underlying different evolutionary models all pointed to a higher variability within Corsicans than within the rest of the Mediterranean reference populations. All Corsican subsamples showed the highest distance with a pooled sample from central Sardinia, thus making recent gene flow between the two neighboring islands unlikely. Hierarchical AMOVA and distance-based multivariate genetic spaces stressed the closeness of Tuscan and Corsican frequency distributions, which could reflect peopling events with different time depths. Anyway, estimated separation times well support the linguistic hypothesis that Neolithic/Chalcolithic events have been far more important than Paleolithic or historical processes in the shaping of present Corsican variability.
The Shawmere anorthosite and OB-1 as lunar highland regolith simulants
NASA Astrophysics Data System (ADS)
Battler, Melissa M.; Spray, John G.
2009-12-01
Anorthosite constitutes a major component of the lunar crust and comprises an important, if not dominant, ingredient of the lunar regolith. Given the need for highland regolith simulants in preparation for lunar surface engineering activities, we have selected an appropriate terrestrial anorthosite and performed crushing trials to generate a particle size distribution comparable to Apollo 16 regolith sample 64 500. The root simulant is derived from a granoblastic facies of the Archean Shawmere Complex of the Kapuskasing Structural Zone of Ontario, Canada. The Shawmere exhibits minimal retrogression, is homogeneous and has an average plagioclase composition of An 78 (bytownite). Previous industrial interest in this calcic anorthosite has resulted in quarrying operations, which provide ease of extraction and access for potential large-scale simulant production. A derivative of the Shawmere involves the addition of olivine slag, crushed to yield a particle size distribution similar to that of the agglutinate and glass components of the Apollo sample. This simulant is referred to as OB-1. The Shawmere and OB-1 regolith simulants are lunar highland analogues, conceived to produce geotechnical properties of benefit to designing and testing drilling, excavation and construction equipment for future lunar surface operations.
Horikawa, Yoshiki; Shimizu, Michiko; Saito, Tsuguyuki; Isogai, Akira; Imai, Tomoya; Sugiyama, Junji
2018-04-01
Chara is a genus of freshwater alga that is evolutionarily observed at the aquatic-terrestrial boundary, whose cellulose microfibrils are similar to those of terrestrial plants regarding the crystallinity and biosynthesis of cellulose. Oven-dried and never-dried celluloses samples were prepared from chara. Terrestrial plant cellulose samples were used as references. The lengths and length distributions of oven-dried and never-dried chara cellulose microfibrils after acid hydrolysis with or without pretreatment by 2,2,6,6-tetramethylpiperidine-1-oxyl (TEMPO)-mediated oxidation, which was used for efficient fibrillation of acid-hydrolyzed products, were observed by transmission electron microscopy. All terrestrial plant celluloses and oven-dried chara cellulose had short nanocrystal-like morphologies of 100-300 nm in length after acid hydrolysis. In contrast, the never-dried chara cellulose had much longer microfibrils of ∼970 nm in length after acid hydrolysis. These results indicated that disordered regions present periodically along the cellulose microfibrils, which cause the formation of cellulose nanocrystals after acid hydrolysis, are not present in inherent chara cellulose microfibrils in water, but are formed artificially under drying or dehydration conditions. Copyright © 2017 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Butler, James J.; Georgiev, Georgi T.; Tveekrem, June L.; Quijada, Manuel; Getty, Stephanie; Hagopian, John G.
2010-10-01
The Bidirectional Reflectance Distribution Function (BRDF) at visible and near-infrared wavelengths of Multi-Wall Carbon NanoTubes (MWCNTs) grown on substrate materials are reported. The BRDF measurements were performed in the Diffuser Calibration Laboratory (DCaL) at NASA's Goddard Space Flight Center, and results at 500nm and 900nm are reported here. In addition, the 8° Directional/Hemispherical Reflectance of the samples is reported from the ultraviolet to shortwave infrared. The 8° Directional/Hemispherical Reflectance was measured in the Optics Branch at NASA's Goddard Space Flight Center. The BRDF was measured at 0° and 45° incident angles and from -80° to +80° scatter angles using a monochromatic source. The optical scatter properties of the samples as represented by their BRDF were found to be strongly influenced by the choice of substrate. As a reference, the optical scattering properties of the carbon nanotubes are compared to the BRDF of Aeroglaze Z306TM and Rippey Ultrapol IVTM, a well-known black paint and black appliqué, respectively. The possibility, promise, and challenges of employing carefully engineered carbon nanotubes in straylight control applications particularly for spaceflight instrumentation is also discussed.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Energy and Resources Group, University of California, Berkeley; Darghouth, Naim R.; Barbose, Galen
2011-06-01
Net metering has become a widespread mechanism in the U.S. for supporting customer adoption of distributed photovoltaics (PV), but has faced challenges as PV installations grow to a larger share of generation in a number of states. This paper examines the value of the bill savings that customers receive under net metering, and the associated role of retail rate design, based on a sample of approximately two hundred residential customers of California's two largest electric utilities. We find that the bill savings per kWh of PV electricity generated varies by more than a factor of four across the customers inmore » the sample, which is largely attributable to the inclining block structure of the utilities' residential retail rates. We also compare the bill savings under net metering to that received under three potential alternative compensation mechanisms, based on California's Market Price Referent (MPR). We find that net metering provides significantly greater bill savings than a full MPR-based feed-in tariff, but only modestly greater savings than alternative mechanisms under which hourly or monthly net excess generation is compensated at the MPR rate.« less
Boué, Franck; El Berbri, Ikhlass; Hormaz, Vanessa; Boucher, Jean-Marc; El Mamy, Ahmed Bezeid; Traore, Abdallah; Fihri, Ouafaa Fassi; Petavy, Anne-Françoise; Dakkak, Allal; Umhang, Gérald
2017-02-01
Cystic Echinococcosis is a parasitic disease caused by the cestode Echinococcus granulosus widely distributed in Africa. Monitoring of this parasite requires access to cyst samples on intermediate hosts observed at the slaughterhouse. In order to facilitate sampling in the field and analysis, the French National Reference Laboratory for Echinococcus spp. has developed a tissue derived from DNA sampling with FTA ® card technology. The DNA samples were taken by applying the FTA ® paper on the germinal layer after opening the cysts. The sampling technique was validated using frozen cysts (n = 76) stored in the laboratory and from field samples (n = 134) taken at the slaughterhouse by veterinarian technicians during meat inspection in Morocco, Mali and Mauritania. DNA was extracted after several weeks of storage at room temperature. PCR assays were performed using primers for generic cestode (cox1) and amplified fragments were sequenced. All samples taken in the lab and 80% of field samples were capable of molecular characterization. Cyst-derived DNA from FTA ® samples can be useful for easy sampling, storage and rapid, safe and cheap shipment. The use of the FTA methodology will facilitate studies in the field to investigate the presence and genetic characterization of E. granulosus sensu lato in African countries. Copyright © 2016 Elsevier Inc. All rights reserved.
Proficiency Tests for Environmental Radioactivity Measurement Organized by an Accredited Laboratory
NASA Astrophysics Data System (ADS)
Aubert, Cédric; Osmond, Mélanie
2008-08-01
For 40 years, STEME (Environmental Sample Processing and Metrology Department) organized international proficiency testing (PT) exercises formerly for WHO (World Health Organization) and EC (European Community) and currently for ASN (French Nuclear Safety Authority). Five PT exercises are organized each year for the measurement of radionuclides (alpha, beta and gamma) in different matrixes (water, soil, biological and air samples) at environmental levels. ASN can deliver a French ministerial agreement to participate on environmental radioactivity measurements French network for laboratories asking it [1]. Since 2006, November, STEME is the first French entity obtaining a COFRAC (French Committee of Accreditation) accreditation as "Interlaboratory Comparisons" for the organization of proficiency tests for environmental radioactivity measurement according to standard International Standard Organization (ISO) 17025 and guide ISO 43-1. STEME has in charge to find, as far as possible, real sample or to create, by radionuclide adding, an adapted sample. STEME realizes the sampling, the samples preparation and the dispatching. STEME is also accredited according to Standard 17025 for radioactivity measurements in environmental samples and determines homogeneity, stability and reference values. After the reception of participating laboratories results, STEME executes statistical treatments in order to verify the normal distribution, to eliminate outliers and to evaluate laboratories performance. Laboratories participate with several objectives, to obtain French agreement, to prove the quality of their analytical performance in regards to standard 17025 or to validate new methods or latest developments. For 2 years, in addition to usual PT exercises, new PT about alpha or beta measurement in air filters, radioactive iodine in carbon cartridges or measurement of environmental dosimeters are organized. These PT exercises help laboratories to improve radioactive measurements and to rectify old mistakes. The PT exercises organized by STEME are becoming essential for French and some European laboratories working in radioactive measurements. The STEME organization, in respect of accreditation references, is presented.
Proficiency Tests for Environmental Radioactivity Measurement Organized by an Accredited Laboratory
DOE Office of Scientific and Technical Information (OSTI.GOV)
Aubert, Cedric; Osmond, Melanie
2008-08-14
For 40 years, STEME (Environmental Sample Processing and Metrology Department) organized international proficiency testing (PT) exercises formerly for WHO (World Health Organization) and EC (European Community) and currently for ASN (French Nuclear Safety Authority). Five PT exercises are organized each year for the measurement of radionuclides (alpha, beta and gamma) in different matrixes (water, soil, biological and air samples) at environmental levels. ASN can deliver a French ministerial agreement to participate on environmental radioactivity measurements French network for laboratories asking it. Since 2006, November, STEME is the first French entity obtaining a COFRAC (French Committee of Accreditation) accreditation as 'Interlaboratorymore » Comparisons' for the organization of proficiency tests for environmental radioactivity measurement according to standard International Standard Organization (ISO) 17025 and guide ISO 43-1. STEME has in charge to find, as far as possible, real sample or to create, by radionuclide adding, an adapted sample. STEME realizes the sampling, the samples preparation and the dispatching. STEME is also accredited according to Standard 17025 for radioactivity measurements in environmental samples and determines homogeneity, stability and reference values. After the reception of participating laboratories results, STEME executes statistical treatments in order to verify the normal distribution, to eliminate outliers and to evaluate laboratories performance.Laboratories participate with several objectives, to obtain French agreement, to prove the quality of their analytical performance in regards to standard 17025 or to validate new methods or latest developments. For 2 years, in addition to usual PT exercises, new PT about alpha or beta measurement in air filters, radioactive iodine in carbon cartridges or measurement of environmental dosimeters are organized. These PT exercises help laboratories to improve radioactive measurements and to rectify old mistakes. The PT exercises organized by STEME are becoming essential for French and some European laboratories working in radioactive measurements.The STEME organization, in respect of accreditation references, is presented.« less
Cohen-Kettenis, Peggy T; Wallien, Madeleine; Johnson, Laurel L; Owen-Anderson, Allison F H; Bradley, Susan J; Zucker, Kenneth J
2006-07-01
A one-factor, 14-item parent-report Gender Identity Questionnaire for Children (GIQC) was developed in a sample of 325 clinic-referred children with gender identity problems and 504 controls from Toronto, Canada (Johnson et al., 2004). In this study, we report a cross-national, cross-clinic comparative analysis of the GIQC on gender-referred children (N = 338) from Toronto and gender-referred children (N = 175) from Utrecht, The Netherlands. Across clinics, the results showed both similarities and differences. Gender-referred boys from Utrecht had a significantly higher total score (indicating more cross-gender behavior) than did gender-referred boys from Toronto, but there was no significant difference for girls. In the Toronto sample, the gender-referred girls had a significantly higher total score than the gender-referred boys, but there was no significant sex difference in the Utrecht sample. Across both clinics, gender-referred children who met the complete DSM criteria for gender identity disorder (GID) had a significantly higher cross-gender score than the gender-referred children who were subthreshold for GID (Cohen's d = 1.11). The results of this study provide the first empirical evidence of relative similarity in cross-gender behavior in a sample of gender-referred children from western Europe when compared to North American children. The results also provide some support for cross-clinic consistency in clinician-based diagnosis of GID.
Polarization in Quarkonium Production
DOE Office of Scientific and Technical Information (OSTI.GOV)
Russ, James S.
Production mechanisms for quarkonium states in hadronic collisions remain difficult to understand. The decay angular distributions of J/more » $$\\psi$$ or $$\\Upsilon(nS)$$ states into $$\\mu^+ \\mu^-$$ final states are sensitive to the matrix elements in the production process and provide a unique tool to evaluate different models. This talk will focus on new results for the spin alignment of $$\\Upsilon(nS)$$ states produced in $$p\\bar{p}$$ collisions at $$\\sqrt{s}$$ = 1.96 TeV using the CDF II detector at the Fermilab Tevatron. The data sample corresponds to an integrated luminosity of 6.7 fb$$^{-1}$$. The angular distributions are analyzed as functions of the transverse momentum of the dimuon final state in both the Collins-Soper and the s-channel helicity frames using a unique data-driven background determination method. Consistency of the analysis is checked by comparing frame-invariant quantities derived from parametrizations of the angular distributions measured in each choice of reference frame. This analysis is the first to quantify the complete three-dimensional angular distribution of $$\\Upsilon(1S), \\Upsilon(2S)$$ and $$\\Upsilon(3S)$$ decays. The decays are nearly isotropic in all frames, even when produced with large transverse momentum.« less
Henry, M J; Pasco, J A; Seeman, E; Nicholson, G C; Sanders, K M; Kotowicz, M A
2001-01-01
Fracture risk is determined by bone mineral density (BMD). The T-score, a measure of fracture risk, is the position of an individual's BMD in relation to a reference range. The aim of this study was to determine the magnitude of change in the T-score when different sampling techniques were used to produce the reference range. Reference ranges were derived from three samples, drawn from the same region: (1) an age-stratified population-based random sample, (2) unselected volunteers, and (3) a selected healthy subset of the population-based sample with no diseases or drugs known to affect bone. T-scores were calculated using the three reference ranges for a cohort of women who had sustained a fracture and as a group had a low mean BMD (ages 35-72 yr; n = 484). For most comparisons, the T-scores for the fracture cohort were more negative using the population reference range. The difference in T-scores reached 1.0 SD. The proportion of the fracture cohort classified as having osteoporosis at the spine was 26, 14, and 23% when the population, volunteer, and healthy reference ranges were applied, respectively. The use of inappropriate reference ranges results in substantial changes to T-scores and may lead to inappropriate management.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hunter, C.; Simpson, J.; Kovats, Z.
Sediments from Soda Creek were evaluated using the Sediment Quality Triad as part of investigations being conducted at the Monsanto Company plant in Soda Springs, Idaho. Information collected by an ecological assessment included metal concentrations (arsenic, cadmium, copper, molybdenum, nickel, selenium, silver, and vanadium), benthic fauna community structure, and sediment toxicity. The collected sediments were composed of sandy-silt sized particles, with 2.4% to 9.1% organic carbon. Metal concentrations at sample stations were elevated relative to sediments collected from reference stations. For example, average cadmium concentrations ranged from 13 to 48 mg/kg at sample stations and 0.72 to 3.2 mg/kg atmore » reference stations; selenium concentrations ranged from 4.7 to 91 mg/kg at sample stations and 0.82 to 2.7 mg/kg at reference stations. Soda Creek has a relatively low flow gradient and the benthic fauna at both reference and sample stations was dominated by oligochaete worms and chironomid midge larvae. Taxonomic richness at individual sites ranged from 4.3 to 6.7 and 6 to 10.3 at reference and sample sites, respectively. There was no significant evidence of toxicity at any location sampled. Cluster analysis showed that the benthic community structure of many of the sample stations could not be distinguished from the reference stations. Canonical correlation analysis showed there was a significant relationship between benthic fauna and metal concentration, but there was not a consistent difference between sample and reference stations. For Soda Creek, local phenomena were more significant to benthic community structure than large-scale patterns of metal accumulation. Using the Triad approach, the authors concluded there has been no adverse effect of metal concentrations on the benthic community of Soda Creek.« less
Impacts on seafloor geology of drilling disturbance in shallow waters.
Corrêa, Iran C S; Toldo, Elírio E; Toledo, Felipe A L
2010-08-01
This paper describes the effects of drilling disturbance on the seafloor of the upper continental slope of the Campos Basin, Brazil, as a result of the project Environmental Monitoring of Offshore Drilling for Petroleum Exploration--MAPEM. Field sampling was carried out surrounding wells, operated by the company PETROBRAS, to compare sediment properties of the seafloor, including grain-size distribution, total organic carbon, and clay mineral composition, prior to drilling with samples obtained 3 and 22 months after drilling. The sampling grid used had 74 stations, 68 of which were located along 7 radials from the well up to a distance of 500 m. The other 6 stations were used as reference, and were located 2,500 m from the well. The results show no significant sedimentological variation in the area affected by drilling activity. The observed sedimentological changes include a fining of grain size, increase in total organic carbon, an increase in gibbsite, illite, and smectite, and a decrease in kaolinite after drilling took place.
The 124Sb activity standardization by gamma spectrometry for medical applications
NASA Astrophysics Data System (ADS)
de Almeida, M. C. M.; Iwahara, A.; Delgado, J. U.; Poledna, R.; da Silva, R. L.
2010-07-01
This work describes a metrological activity determination of 124Sb, which can be used as radiotracer, applying gamma spectrometry methods with hyper pure germanium detector and efficiency curves. This isotope with good activity and high radionuclidic purity is employed in the form of meglumine antimoniate (Glucantime) or sodium stibogluconate (Pentostam) to treat leishmaniasis. 124Sb is also applied in animal organ distribution studies to solve some questions in pharmacology. 124Sb decays by β-emission and it produces several photons (X and gamma rays) with energy varying from 27 to 2700 keV. Efficiency curves to measure point 124Sb solid sources were obtained from a 166mHo standard that is a multi-gamma reference source. These curves depend on radiation energy, sample geometry, photon attenuation, dead time and sample-detector position. Results for activity determination of 124Sb samples using efficiency curves and a high purity coaxial germanium detector were consistent in different counting geometries. Also uncertainties of about 2% ( k=2) were obtained.
Quasars in the Galactic Anti-Center Area from LAMOST DR3
NASA Astrophysics Data System (ADS)
Huo, Zhi-Ying; Liu, Xiao-Wei; Shi, Jian-Rong; Xiang, Mao-Sheng; Huang, Yang; Yuan, Hai-Bo; Zhang, Jian-Nan; Zhang, Wei; Wang, Jian-Ling; Wu, Yu-Zhong; Cao, Zi-Huang; Zhang, Yong; Hou, Yong-Hui; Wang, Yue-Fei
2017-03-01
We present a sample of quasars discovered in an area near the Galactic Anti-Center covering 150^\\circ ≤ l≤ 210^\\circ and | b| ≤ 30^\\circ , based on LAMOST Data Release 3 (DR3). This sample contains 151 spectroscopically confirmed quasars. Among them 80 are newly discovered with LAMOST. All these quasars are very bright, with i magnitudes peaking around 17.5 mag. All the new quasars were discovered serendipitously from objects that were originally targeted with LAMOST as stars having bluer colors, except for a few candidates targeted as variable, young stellar objects. This bright quasar sample at low Galactic latitudes will help fill the gap in the spatial distribution of known quasars near the Galactic disk that are used to construct an astrometric reference frame for the purpose of accurate proper motion measurements that can be applied to, for example, Gaia. They are also excellent tracers to probe the kinematics and chemistry of the interstellar medium in the Milky Way disk and halo via absorption line spectroscopy.
Genotype Imputation with Millions of Reference Samples
Browning, Brian L.; Browning, Sharon R.
2016-01-01
We present a genotype imputation method that scales to millions of reference samples. The imputation method, based on the Li and Stephens model and implemented in Beagle v.4.1, is parallelized and memory efficient, making it well suited to multi-core computer processors. It achieves fast, accurate, and memory-efficient genotype imputation by restricting the probability model to markers that are genotyped in the target samples and by performing linear interpolation to impute ungenotyped variants. We compare Beagle v.4.1 with Impute2 and Minimac3 by using 1000 Genomes Project data, UK10K Project data, and simulated data. All three methods have similar accuracy but different memory requirements and different computation times. When imputing 10 Mb of sequence data from 50,000 reference samples, Beagle’s throughput was more than 100× greater than Impute2’s throughput on our computer servers. When imputing 10 Mb of sequence data from 200,000 reference samples in VCF format, Minimac3 consumed 26× more memory per computational thread and 15× more CPU time than Beagle. We demonstrate that Beagle v.4.1 scales to much larger reference panels by performing imputation from a simulated reference panel having 5 million samples and a mean marker density of one marker per four base pairs. PMID:26748515
Chatrchyan, Serguei
2014-07-23
Dijet production has been measured in pPb collisions at a nucleon-nucleon centre-of-mass energy of 5.02 TeV. A data sample corresponding to an integrated luminosity of 35 inverse-nanobarns was collected using the Compact Muon Solenoid detector at the Large Hadron Collider. The dijet transverse momentum balance, azimuthal angle correlations, and pseudorapidity distributions are studied as a function of the transverse energy in the forward calorimeters (more » $$E_T^{4\\lt |\\eta| \\lt 5.2}$$). For pPb collisions, the dijet transverse momentum ratio and the width of the distribution of dijet azimuthal angle difference are comparable to the same quantities obtained from a simulated pp reference and insensitive to $$E_T^{4\\lt |\\eta| \\lt 5.2}$$. In contrast, the mean value of the dijet pseudorapidity is found to change monotonically with increasing $$E_T^{4\\lt |\\eta| \\lt 5.2}$$, indicating a correlation between the energy emitted at large pseudorapidity and the longitudinal motion of the dijet frame. As a result, the pseudorapidity distribution of the dijet system is compared with next-to-leading-order perturbative QCD predictions obtained from both nucleon and nuclear parton distribution functions, and the data more closely match the latter.« less
NASA Technical Reports Server (NTRS)
Macenka, Steven A.; Chipman, Russell A.; Daugherty, Brian J.; McClain, Stephen C.
2012-01-01
A report discusses the difficulty of measuring scattering properties of coated mirrors extremely close to the specular reflection peak. A prototype Optical Hetero dyne Near-angle Scatterometer (OHNS) was developed. Light from a long-coherence-length (>150 m) 532-nm laser is split into two arms. Acousto-optic modulators frequency shift the sample and reference beams, establishing a fixed beat frequency between the beams. The sample beam is directed at very high f/# onto a mirror sample, and the point spread function (PSF) formed after the mirror sample is scanned with a pinhole. This light is recombined by a non-polarizing beam splitter and measured through heterodyne detection with a spectrum analyzer. Polarizers control the illuminated and analyzed polarization states, allowing the polarization dependent scatter to be measured. The bidirectional reflective or scattering distribution function is normally measured through use of a scattering goniometer instrument. The instrumental beam width (collection angle span) over which the scatterometer responds is typically many degrees. The OHNS enables measurement at angles as small as the first Airy disk diameter.
A 2x2 W-Band Reference Time-Shifted Phase-Locked Transmitter Array in 65nm CMOS Technology
NASA Technical Reports Server (NTRS)
Tang, Adrian; Virbila, Gabriel; Hsiao, Frank; Wu, Hao; Murphy, David; Mehdi, Imran; Siegel, P. H.; Chang, M-C. Frank
2013-01-01
This paper presents a complete 2x2 phased array transmitter system operating at W-band (90-95 GHz) which employs a PLL reference time-shifting approach instead of using traditional mm-wave phase shifters. PLL reference shifting enables a phased array to be distributed over multiple chips without the need for coherent mm-wave signal distribution between chips. The proposed phased array transmitter system consumes 248 mW per array element when implemented in a 65 nm CMOS technology.
Mederico, Maracelly; Paoli, Mariela; Zerpa, Yajaira; Briceño, Yajaira; Gómez-Pérez, Roald; Martínez, José Luis; Camacho, Nolis; Cichetti, Rosanna; Molina, Zarela; Mora, Yolanda; Valeri, Lenin
2013-05-01
To collect regional reference values of waist circumference (WC), and waist/hip ratio (WHR) in children and adolescents from Merida, Venezuela, and to compare them to international references. A total of 919 students aged 9-17 years from public and private educational establishments were assessed. Weight, height, WC, and WHR were measured. Outliers (± 3 SD Z-Score) were excluded from the data collected. Percentile distribution of the tested variables was done by age and sex. Fifty-one percent of subjects were female, and 52.7% were from public institutions. WC (p=0.001) and WHR (p=0.0001) were statistically higher in boys. With advancing age, WC increased in both sexes, while WHR showed the opposite behavior (p=0.0001 for both). The 90th percentile (pc) for WC ranged from 69.7 and 83.6 cm in girls and from 69.2 and 86.7 cm in boys. The 90th pc values of WHR ranged from 0.79 and 0.91 in girls and from 0.86 and 0.93 in boys. Overall, our WC and WHR values were lower than North American values and similar to those of some Latin American references. Percentile reference charts for WC and WHR specific for age and sex, obtained from a representative sample of children and adolescents from Mérida, Venezuela, are provided. They may be used regionally, both for individual assessment and to implement prevention policies. Copyright © 2012 SEEN. Published by Elsevier Espana. All rights reserved.
Bravo, Sandra; García-Ordiales, Efrén; García-Navarro, Francisco Jesús; Amorós, José Ángel; Pérez-de-Los-Reyes, Caridad; Jiménez-Ballesta, Raimundo; Esbrí, José María; García-Noguero, Eva María; Higueras, Pablo
2017-09-07
Castilla-La Mancha (central Spain) is a region characterized by significant agricultural production aimed at high-quality food products such as wine and olive oil. The quality of agricultural products depends directly on the soil quality. Soil geochemistry, including dispersion maps and the recognition of baselines and anomalies of various origins, is the most important tool to assess soil quality. With this objective, 200 soil samples were taken from agricultural areas distributed among the different geological domains present in the region. Analysis of these samples included evaluation of edaphological parameters (reactivity, electrical conductivity, organic matter content) and the geochemistry of major and trace elements by X-ray fluorescence. The dataset obtained was statistically analyzed for major elements and, in the case of trace elements, was normalized with respect to Al and analyzed using the relative cumulative frequency (RCF) distribution method. Furthermore, the geographic distribution of analytical data was characterized and analyzed using the kriging technique, with a correspondence found between major and trace elements in the different geologic domains of the region as well as with the most important mining areas. The results show an influence of the clay fraction present in the soil, which acts as a repository for trace elements. On the basis of the results, of the possible elements related with clay that could be used for normalization, Al was selected as the most suitable, followed by Fe, Mn, and Ti. Reference values estimated using this methodology were lower than those estimated in previous studies.
Kretzschmar, Moritz; Schilling, Thomas; Vogt, Andreas; Rothen, Hans Ulrich; Borges, João Batista; Hachenberg, Thomas; Larsson, Anders; Baumgardner, James E; Hedenstierna, Göran
2013-10-15
The mismatching of alveolar ventilation and perfusion (VA/Q) is the major determinant of impaired gas exchange. The gold standard for measuring VA/Q distributions is based on measurements of the elimination and retention of infused inert gases. Conventional multiple inert gas elimination technique (MIGET) uses gas chromatography (GC) to measure the inert gas partial pressures, which requires tonometry of blood samples with a gas that can then be injected into the chromatograph. The method is laborious and requires meticulous care. A new technique based on micropore membrane inlet mass spectrometry (MMIMS) facilitates the handling of blood and gas samples and provides nearly real-time analysis. In this study we compared MIGET by GC and MMIMS in 10 piglets: 1) 3 with healthy lungs; 2) 4 with oleic acid injury; and 3) 3 with isolated left lower lobe ventilation. The different protocols ensured a large range of normal and abnormal VA/Q distributions. Eight inert gases (SF6, krypton, ethane, cyclopropane, desflurane, enflurane, diethyl ether, and acetone) were infused; six of these gases were measured with MMIMS, and six were measured with GC. We found close agreement of retention and excretion of the gases and the constructed VA/Q distributions between GC and MMIMS, and predicted PaO2 from both methods compared well with measured PaO2. VA/Q by GC produced more widely dispersed modes than MMIMS, explained in part by differences in the algorithms used to calculate VA/Q distributions. In conclusion, MMIMS enables faster measurement of VA/Q, is less demanding than GC, and produces comparable results.
NASA Astrophysics Data System (ADS)
Li, Qian; Zhu, Changhua; Ma, Shuquan; Wei, Kejin; Pei, Changxing
2018-04-01
Measurement-device-independent quantum key distribution (MDI-QKD) is immune to all detector side-channel attacks. However, practical implementations of MDI-QKD, which require two-photon interferences from separated independent single-photon sources and a nontrivial reference alignment procedure, are still challenging with current technologies. Here, we propose a scheme that significantly reduces the experimental complexity of two-photon interferences and eliminates reference frame alignment by the combination of plug-and-play and reference frame independent MDI-QKD. Simulation results show that the secure communication distance can be up to 219 km in the finite-data case and the scheme has good potential for practical MDI-QKD systems.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Greenblatt, Jeffery B.; Yang, Hung-Chia; Desroches, Louis-Benoit
2013-04-01
We present two post-stratification weighting methods to validate survey data collected using Amazon Mechanical Turk (AMT). Two surveys focused on appliance and consumer electronics devices were administered in the spring and summer of 2012 to each of approximately 3,000 U.S. households. Specifically, the surveys asked questions about residential refrigeration products, televisions (TVs) and set-top boxes (STBs). Filtered data were assigned weights using each of two weighting methods, termed “sequential” and “simultaneous,” by examining up to eight demographic variables (income, education, gender, race, Hispanic origin, number of occupants, ages of occupants, and geographic region) in comparison to reference U.S. demographic datamore » from the 2009 Residential Energy Consumption Survey (RECS). Five key questions from the surveys (number of refrigerators, number of freezers, number of TVs, number of STBs and primary service provider) were evaluated with a set of statistical tests to determine whether either method improved the agreement of AMT with reference data, and if so, which method was better. The statistical tests used were: differences in proportions, distributions of proportions (using Pearson’s chi-squared test), and differences in average numbers of devices as functions of all demographic variables. The results indicated that both methods generally improved the agreement between AMT and reference data, sometimes greatly, but that the simultaneous method was usually superior to the sequential method. Some differences in sample populations were found between the AMT and reference data. Differences in the proportion of STBs reflected large changes in the STB market since the time our reference data was acquired in 2009. Differences in the proportions of some primary service providers suggested real sample bias, with the possible explanation that AMT user are more likely to subscribe to providers who also provide home internet service. Differences in other variables, while statistically significant in some cases, were nonetheless considered to be minor. Depending on the intended purpose of the data collected using AMT, these biases may or may not be important; to correct them, additional questions and/or further post-survey adjustments could be employed. In general, based on the analysis methods and the sample datasets used in this study, AMT surveys appeared to provide useful data on appliance and consumer electronics devices.« less
Fetal-maternal erythrocyte distribution
... under the skin) Infection (a slight risk any time the skin is broken) Alternative Names Kleihauer-Betke stain; Flow cytometry - fetal-maternal erythrocyte distribution; Rh incompatibility - erythrocyte distribution References Chernecky CC, Berger ...
Equivalence Testing of Complex Particle Size Distribution Profiles Based on Earth Mover's Distance.
Hu, Meng; Jiang, Xiaohui; Absar, Mohammad; Choi, Stephanie; Kozak, Darby; Shen, Meiyu; Weng, Yu-Ting; Zhao, Liang; Lionberger, Robert
2018-04-12
Particle size distribution (PSD) is an important property of particulates in drug products. In the evaluation of generic drug products formulated as suspensions, emulsions, and liposomes, the PSD comparisons between a test product and the branded product can provide useful information regarding in vitro and in vivo performance. Historically, the FDA has recommended the population bioequivalence (PBE) statistical approach to compare the PSD descriptors D50 and SPAN from test and reference products to support product equivalence. In this study, the earth mover's distance (EMD) is proposed as a new metric for comparing PSD particularly when the PSD profile exhibits complex distribution (e.g., multiple peaks) that is not accurately described by the D50 and SPAN descriptor. EMD is a statistical metric that measures the discrepancy (distance) between size distribution profiles without a prior assumption of the distribution. PBE is then adopted to perform statistical test to establish equivalence based on the calculated EMD distances. Simulations show that proposed EMD-based approach is effective in comparing test and reference profiles for equivalence testing and is superior compared to commonly used distance measures, e.g., Euclidean and Kolmogorov-Smirnov distances. The proposed approach was demonstrated by evaluating equivalence of cyclosporine ophthalmic emulsion PSDs that were manufactured under different conditions. Our results show that proposed approach can effectively pass an equivalent product (e.g., reference product against itself) and reject an inequivalent product (e.g., reference product against negative control), thus suggesting its usefulness in supporting bioequivalence determination of a test product to the reference product which both possess multimodal PSDs.
Variability of 137Cs inventory at a reference site in west-central Iran.
Bazshoushtari, Nasim; Ayoubi, Shamsollah; Abdi, Mohammad Reza; Mohammadi, Mohammad
2016-12-01
137 Cs technique has been widely used for the evaluation rates and patterns of soil erosion and deposition. This technique requires an accurate estimate of the values of 137 Cs inventory at the reference site. This study was conducted to evaluate the variability of the inventory of 137 Cs regarding to the sampling program including sample size, distance and sampling method at a reference site located in vicinity of Fereydan district in Isfahan province, west-central Iran. Two 3 × 8 grids were established comprising large grid (35 m length and 8 m width), and small grid (24 m length and 6 m width). At each grid intersection two soil samples were collected from 0 to 15 cm and 15-30 cm depths, totally 96 soil samples from 48 sampling points. Coefficients of variation for 137 Cs inventory in the soil samples was relatively low (CV = 15%), and the sampling distance and methods used did not significantly affect the 137 Cs inventories across the studied reference site. To obtain a satisfactory estimate of the mean 137 Cs activity in the reference sites, particularly those located in the semiarid regions, it is recommended to collect at least four samples along in a grid pattern 3 m apart. Copyright © 2016 Elsevier Ltd. All rights reserved.
Micron-Scale Differential Scanning Calorimeter on a Chip
Cavicchi, Richard E; Poirier, Gregory Ernest; Suehle, John S; Gaitan, Michael; Tea, Nim H
1998-06-30
A differential scanning microcalorimeter produced on a silicon chip enables microscopic scanning calorimetry measurements of small samples and thin films. The chip may be fabricated using standard CMOS processes. The microcalorimeter includes a reference zone and a sample zone. The reference and sample zones may be at opposite ends of a suspended platform or may reside on separate platforms. An integrated polysilicon heater provides heat to each zone. A thermopile consisting of a succession of thermocouple junctions generates a voltage representing the temperature difference between the reference and sample zones. Temperature differences between the zones provide information about the chemical reactions and phase transitions that occur in a sample placed in the sample zone.
Damage Detection of CFRP Plates by Full-Spectral Analysis of a Fibre Bragg Grating Sensor Signal
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mizutani, Yoshihiro; Solid and Structures Engineering Laboratory, Department of Mechanical Sciences and Engineering, Tokyo Institute of Technology, Japan, 2-12-1-I1-70, Ookayama, Meguro-ku, Tokyo 152-8552; Groves, Roger M.
2010-05-28
This paper describes the measurement of average strain, strain distribution and vibration of cantilever beam made of Carbon Fiber Reinforced Plastics (CFRP), using a single Fibre Bragg Grating (FBG) sensor mounted on the beam surface. Average strain is determined from the displacement of the peak wavelength of reflected light from the FBG sensor. Unstrained reference FBG sensors were used to compensate for temperature drift and the photoelastic coefficient (P{sub e}), which was used to calculate the gauge factor. Measured strains agree with those measured by a resistance foil strain gauge attached to the sample. Stress distributions are measured by monitoringmore » the variation in the full width half maximum (FWHM) values of the reflected spectrum, using a proposed optical analytical model, described in the paper. FWHM values were measured for both the cantilever test beam and a for a reference beam, loaded using a four-point bending rig. The trend of the stress distribution for the test beam matches with our analytical model, however with a relatively large noise present in the experimentally determined data. The vibration of cantilever beam was measured by temporal analysis of the peak reflection wavelength. This technique is very stable as measurements are not affected by variations in the signal amplitude. Finally an application of FBG sensors for damage detection of CFRP plates is demonstrated, by measuring the average strain and natural frequency. With small defects of different sizes applied to the CFRP plate, average strains were seen to increase with damage size and the natural frequency decreased with damage size.« less