NASA Astrophysics Data System (ADS)
van Broekhuizen, Pieter; van Broekhuizen, Fleur; Cornelissen, Ralf; Reijnders, Lucas
2012-03-01
Nano reference values (NRVs) for occupational use of nanomaterials were tested as provisional substitute for Occupational Exposure Limits (OELs). NRVs can be used as provisional limit values until Health-Based OELs or derived no-effect levels (DNEL) become available. NRVs were defined for 8 h periods (time weighted average) and for short-term exposure periods (15 min-time weighted average). To assess the usefulness of these NRVs, airborne number concentrations of nanoparticles (NPs) in the workplace environment were measured during paint manufacturing, electroplating, light equipment manufacturing, non-reflective glass production, production of pigment concentrates and car refinishing. Activities monitored were handling of solid engineered NPs (ENP), abrasion, spraying and heating during occupational use of nanomaterials (containing ENPs) and machining nanosurfaces. The measured concentrations are often presumed to contain ENPs as well as process-generated NPs (PGNP). The PGNP are found to be a significant source for potential exposure and cannot be ignored in risk assessment. Levels of NPs identified in workplace air were up to several millions of nanoparticles/cm3. Conventional components in paint manufacturing like CaCO3 and talc may contain a substantial amount of nanosized particulates giving rise to airborne nanoparticle concentrations. It is argued that risk assessments carried out for e.g. paint manufacturing processes using conventional non-nano components should take into account potential nanoparticle emissions as well. The concentrations measured were compared with particle-based NRVs and with mass-based values that have also been proposed for workers protection. It is concluded that NRVs can be used for risk management for handling or processing of nanomaterials at workplaces provided that the scope of NRVs is not limited to ENPs only, but extended to the exposure to process-generated NPs as well.
Exposure limits for nanoparticles: report of an international workshop on nano reference values.
van Broekhuizen, Pieter; van Veelen, Wim; Streekstra, Willem-Henk; Schulte, Paul; Reijnders, Lucas
2012-07-01
This article summarizes the outcome of the discussions at the international workshop on nano reference values (NRVs), which was organized by the Dutch trade unions and employers' organizations and hosted by the Social Economic Council in The Hague in September 2011. It reflects the discussions of 80 international participants representing small- and medium-size enterprises (SMEs), large companies, trade unions, governmental authorities, research institutions, and non-governmental organizations (NGOs) from many European countries, USA, India, and Brazil. Issues that were discussed concerned the usefulness and acceptability of precaution-based NRVs as a substitute for health-based occupational exposure limits (OELs) and derived no-effect levels (DNELs) for manufactured nanoparticles (NPs). Topics concerned the metrics for measuring NPs, the combined exposure to manufactured nanomaterials (MNMs) and process-generated NPs, the use of the precautionary principle, the lack of information about the presence of nanomaterials, and the appropriateness of soft regulation for exposure control. The workshop concluded that the NRV, as an 8-h time-weighted average, is a comprehensible and useful instrument for risk management of professional use of MNMs with a dispersible character. The question remains whether NRVs, as advised for risk management by the Dutch employers' organization and trade unions, should be under soft regulation or that a more binding regulation is preferable.
Aggett, Peter J; Hathcock, John; Jukes, David; Richardson, David P; Calder, Philip C; Bischoff-Ferrari, Heike; Nicklas, Theresa; Mühlebach, Stefan; Kwon, Oran; Lewis, Janine; Lugard, Maurits J F; Prock, Peter
2012-03-01
Codex documents may be used as educational and consensus materials for member governments. Also, the WTO SPS Agreement recognizes Codex as the presumptive international authority on food issues. Nutrient bioavailability is a critical factor in determining the ability of nutrients to provide beneficial effects. Bioavailability also influences the quantitative dietary requirements that are the basis of nutrient intake recommendations and NRVs. Codex, EFSA and some national regulatory authorities have established guidelines or regulations that will permit several types of health claims. The scientific basis for claims has been established by the US FDA and EFSA, but not yet by Codex. Evidence-based nutrition differs from evidence-based medicine, but the differences are only recently gaining recognition. Health claims on foods may provide useful information to consumers, but many will interpret the information to mean that they can rely upon the food or nutrient to eliminate a disease risk. NRVs are designed to provide a quantitative basis for comparing the nutritive values of foods, helping to illustrate how specific foods fit into the overall diet. The INL-98 and the mean of adult male and female values provide NRVs that are sufficient when used as targets for individual intakes by most adults. WTO recognizes Codex as the primary international authority on food issues. Current regulatory schemes based on recommended dietary allowances are trade restrictive. A substantial number of decisions by the EFSA could lead to violation of WTO agreements.
Xiao, Yuming; Koutmos, Markos; Case, David A; Coucouvanis, Dimitri; Wang, Hongxin; Cramer, Stephen P
2006-05-14
We have used four vibrational spectroscopies--FT-IR, FT-Raman, resonance Raman, and 57Fe nuclear resonance vibrational spectroscopy (NRVS)--to study the normal modes of the Fe-S cluster in [(n-Bu)4N]2[Fe4S4(SPh)4]. This [Fe4S4(SR)4]2- complex serves as a model for the clusters in 4Fe ferredoxins and high-potential iron proteins (HiPIPs). The IR spectra exhibited differences above and below the 243 K phase transition. Significant shifts with 36S substitution into the bridging S positions were also observed. The NRVS results were in good agreement with the low temperature data from the conventional spectroscopies. The NRVS spectra were interpreted by normal mode analysis using optimized Urey-Bradley force fields (UBFF) as well as from DFT theory. For the UBFF calculations, the parameters were refined by comparing calculated and observed NRVS frequencies and intensities. The frequency shifts after 36S substitution were used as an additional constraint. A D 2d symmetry Fe4S4S'4 model could explain most of the observed frequencies, but a better match to the observed intensities was obtained when the ligand aromatic rings were included for a D 2d Fe4S4(SPh)4 model. The best results were obtained using the low temperature structure without symmetry constraints. In addition to stretching and bending vibrations, low frequency modes between approximately 50 and 100 cm(-1) were observed. These modes, which have not been seen before, are interpreted as twisting motions with opposing sides of the cube rotating in opposite directions. In contrast with a recent paper on a related Fe4S4 cluster, we find no need to assign a large fraction of the low frequency NRVS intensity to 'rotational lattice modes'. We also reassign the 430 cm(-1) band as primarily an elongation of the thiophenolate ring, with approximately 10% terminal Fe-S stretch character. This study illustrates the benefits of combining NRVS with conventional Raman and IR analysis for characterization of Fe-S centers. DFT theory is shown to provide remarkable agreement with the experimental NRVS data. These results provide a reference point for the analysis of more complex Fe-S clusters in proteins.
Wang, Hongxin; Yoda, Yoshitaka; Dong, Weibing; Huang, Songping D
2013-09-01
The conventional energy calibration for nuclear resonant vibrational spectroscopy (NRVS) is usually long. Meanwhile, taking NRVS samples out of the cryostat increases the chance of sample damage, which makes it impossible to carry out an energy calibration during one NRVS measurement. In this study, by manipulating the 14.4 keV beam through the main measurement chamber without moving out the NRVS sample, two alternative calibration procedures have been proposed and established: (i) an in situ calibration procedure, which measures the main NRVS sample at stage A and the calibration sample at stage B simultaneously, and calibrates the energies for observing extremely small spectral shifts; for example, the 0.3 meV energy shift between the 100%-(57)Fe-enriched [Fe4S4Cl4](=) and 10%-(57)Fe and 90%-(54)Fe labeled [Fe4S4Cl4](=) has been well resolved; (ii) a quick-switching energy calibration procedure, which reduces each calibration time from 3-4 h to about 30 min. Although the quick-switching calibration is not in situ, it is suitable for normal NRVS measurements.
What Can Be Learned from Nuclear Resonance Vibrational Spectroscopy: Vibrational Dynamics and Hemes
2017-01-01
Nuclear resonance vibrational spectroscopy (NRVS; also known as nuclear inelastic scattering, NIS) is a synchrotron-based method that reveals the full spectrum of vibrational dynamics for Mössbauer nuclei. Another major advantage, in addition to its completeness (no arbitrary optical selection rules), is the unique selectivity of NRVS. The basics of this recently developed technique are first introduced with descriptions of the experimental requirements and data analysis including the details of mode assignments. We discuss the use of NRVS to probe 57Fe at the center of heme and heme protein derivatives yielding the vibrational density of states for the iron. The application to derivatives with diatomic ligands (O2, NO, CO, CN–) shows the strong capabilities of identifying mode character. The availability of the complete vibrational spectrum of iron allows the identification of modes not available by other techniques. This permits the correlation of frequency with other physical properties. A significant example is the correlation we find between the Fe–Im stretch in six-coordinate Fe(XO) hemes and the trans Fe–N(Im) bond distance, not possible previously. NRVS also provides uniquely quantitative insight into the dynamics of the iron. For example, it provides a model-independent means of characterizing the strength of iron coordination. Prediction of the temperature-dependent mean-squared displacement from NRVS measurements yields a vibrational “baseline” for Fe dynamics that can be compared with results from techniques that probe longer time scales to yield quantitative insights into additional dynamical processes. PMID:28921972
High-Frequency Fe-H Vibrations in a Bridging Hydride Complex Characterized by NRVS and DFT.
Pelmenschikov, Vladimir; Gee, Leland B; Wang, Hongxin; MacLeod, K Cory; McWilliams, Sean F; Skubi, Kazimer L; Cramer, Stephen P; Holland, Patrick L
2018-05-30
High-spin iron species with bridging hydrides have been detected in species trapped during nitrogenase catalysis, but there are few general methods of evaluating Fe-H bonds in high-spin multinuclear iron systems. An 57 Fe nuclear resonance vibrational spectroscopy (NRVS) study on an Fe(μ-H) 2 Fe model complex reveals Fe-H stretching vibrations for bridging hydrides at frequencies greater than 1200 cm -1 . These isotope-sensitive vibrational bands are not evident in infrared (IR) spectra, showing the power of NRVS for identifying hydrides in this high-spin iron system. Complementary density functional theory (DFT) calculations elucidate the normal modes of the rhomboidal iron hydride core. © 2018 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.
Kuchenreuther, Jon M.; Guo, Yisong; Wang, Hongxin; Myers, William K.; George, Simon J.; Boyke, Christine A.; Yoda, Yoshitaka; Alp, E. Ercan; Zhao, Jiyong; Britt, R. David; Swartz, James R.; Cramer, Stephen P.
2013-01-01
The [FeFe] hydrogenase from Clostridium pasteurianum (CpI) harbors four Fe–S clusters that facilitate electron transfer to the H-cluster, a ligand-coordinated six-iron prosthetic group that catalyzes the redox interconversion of protons and H2. Here, we have used 57Fe nuclear resonance vibrational spectroscopy (NRVS) to study the iron centers in CpI, and we compare our data to that for a [4Fe–4S] ferredoxin as well as a model complex resembling the [2Fe]H catalytic domain of the H-cluster. In order to enrich the hydrogenase with 57Fe nuclei, we used cell-free methods to post-translationally mature the enzyme. Specifically, inactive CpI apoprotein with 56Fe-labeled Fe–S clusters was activated in vitro using 57Fe-enriched maturation proteins. This approach enabled us to selectively label the [2Fe]H subcluster with 57Fe, which NRVS confirms by detecting 57Fe–CO and 57Fe–CN normal modes from the H-cluster nonprotein ligands. The NRVS and iron quantification results also suggest that the hydrogenase contains a second 57Fe–S cluster. EPR spectroscopy indicates that this 57Fe-enriched metal center is not the [4Fe– 4S]H subcluster of the H-cluster. This finding demonstrates that the CpI hydrogenase retained an 56Fe-enriched [4Fe–4S]H cluster during in vitro maturation, providing unambiguous evidence for stepwise assembly of the H-cluster. In addition, this work represents the first NRVS characterization of [FeFe] hydrogenases. PMID:23249091
Nutritional adequacy of energy restricted diets for young obese women.
O'Connor, Helen; Munas, Zahra; Griffin, Hayley; Rooney, Kieron; Cheng, Hoi Lun; Steinbeck, Katharine
2011-01-01
Energy restricted meal plans may compromise nutrient intake. This study used diet modelling to assess the nutritional adequacy of energy restricted meal plans designed for weight management in young obese women. Diet modelling of 6000 kJ/d animal protein based meal plans was performed using Australian nutrient databases with adequacy compared to the Australian Nutrient Reference Values (NRVs) for women (19-30 years). One diet plan was based on the higher carbohydrate (HC) version of the Australian Guide to Healthy Eating for women 19-60 years. An alternative higher protein (HP) plan was adapted from the CSIRO Total Wellbeing Diet. Vegan and lacto-ovo versions of these plans were also modelled and compared to the appropriate vegetarian NRVs. Both animal protein diets met the estimated average requirement (EAR) or adequate intake (AI) for all nutrients analysed. The recommended dietary intake (RDI) was also satisfied, except for iron. HC met 75±30% and HP 81±31% of the iron RDI when red meat and iron fortified cereal were both included three days a week, and remained below the RDI even when red meat was increased to seven days. Iron for the modified vegan (57±5% HC; 66±4% HP) and lacto-ovo (48±6% HC; 59±7% HP) plans was below the RDI and zinc below the EAR for the vegan (76±8% HC; 84±9% HP) plans. The 6000 kJ/d animal protein meal plans met the RDI for all nutrients except iron. Iron and zinc failed to meet the vegetarian RDI and EAR respectively for the vegan plans.
Lehnert, Nicolai; Galinato, Mary Grace I; Paulat, Florian; Richter-Addo, George B; Sturhahn, Wolfgang; Xu, Nan; Zhao, Jiyong
2010-05-03
This study presents Nuclear Resonance Vibrational Spectroscopy (NRVS) data on the five-coordinate (5C) ferrous heme-nitrosyl complex [Fe(OEP)(NO)] (1, OEP(2-) = octaethylporphyrinato dianion) and the corresponding (15)N(18)O labeled complex. The obtained spectra identify two isotope sensitive features at 522 and 388 cm(-1), which shift to 508 and 381 cm(-1), respectively, upon isotope labeling. These features are assigned to the Fe-NO stretch nu(Fe-NO) and the in-plane Fe-N-O bending mode delta(ip)(Fe-N-O), the latter has been unambiguously assigned for the first time for 1. The obtained NRVS data were simulated using our quantum chemistry centered normal coordinate analysis (QCC-NCA). Since complex 1 can potentially exist in 12 different conformations involving the FeNO and peripheral ethyl orientations, extended density functional theory (DFT) calculations and QCC-NCA simulations were performed to determine how these conformations affect the NRVS properties of [Fe(OEP)NO]. These results show that the properties and force constants of the FeNO unit are hardly affected by the conformational changes involving the ethyl substituents. On the other hand, the NRVS-active porphyrin-based vibrations around 340-360, 300-320, and 250-270 cm(-1) are sensitive to the conformational changes. The spectroscopic changes observed in these regions are due to selective mechanical couplings of one component of E(u)-type (in ideal D(4h) symmetry) porphyrin-based vibrations with the in-plane Fe-N-O bending mode. This leads to the observed variations in Fe(OEP) core mode energies and NRVS intensities without affecting the properties of the FeNO unit. The QCC-NCA simulated NRVS spectra of 1 show excellent agreement with experiment, and indicate that conformer F is likely present in the samples of this complex investigated here. The observed porphyrin-based vibrations in the NRVS spectra of 1 are also assigned based on the QCC-NCA results. The obtained force constants of the Fe-NO and N-O bonds are 2.83-2.94 (based on the DFT functional applied) and about 12.15 mdyn/A, respectively. The electronic structures of 5C ferrous heme-nitrosyls in different model complexes are then analyzed, and variations in their properties based on different porphyrin substituents are explained. Finally, the shortcomings of different DFT functionals in describing the axial FeNO subunit in heme-nitrosyls are elucidated.
Yadav, Manoj Kumar; S, Aravindan; Ngangkham, Umakanta; Shubudhi, H N; Bag, Manas Kumar; Adak, Totan; Munda, Sushmita; Samantaray, Sanghamitra; Jena, Mayabini
2017-01-01
Rice blast disease caused by Magnaporthe oryzae is one of the most destructive disease causing huge losses to rice yield in different parts of the world. Therefore, an attempt has been made to find out the resistance by screening and studying the genetic diversity of eighty released rice varieties by National Rice Research Institute, Cuttack (NRVs) using molecular markers linked to twelve major blast resistance (R) genes viz Pib, Piz, Piz-t, Pik, Pik-p, Pikm Pik-h, Pita/Pita-2, Pi2, Pi9, Pi1 and Pi5. Out of which, nineteen varieties (23.75%) showed resistance, twenty one were moderately resistant (26.25%) while remaining forty varieties (50%) showed susceptible in uniform blast nursery. Rice varieties possessing blast resistance genes varied from four to twelve and the frequencies of the resistance genes ranged from 0 to 100%. The cluster analysis grouped the eighty NRVs into two major clusters at 63% level of genetic similarity coefficient. The PIC value for seventeen markers varied from 0 to 0.37 at an average of 0.20. Out of seventeen markers, only five markers, 195R-1, Pi9-i, Pita3, YL155/YL87 and 40N23r corresponded to three broad spectrum R genes viz. Pi9, Pita/Pita2 and Pi5 were found to be significantly associated with the blast disease with explaining phenotypic variance from 3.5% to 7.7%. The population structure analysis and PCoA divided the entire 80 NRVs into two sub-groups. The outcome of this study would help to formulate strategies for improving rice blast resistance through genetic studies, plant-pathogen interaction, identification of novel R genes, development of new resistant varieties through marker-assisted breeding for improving rice blast resistance in India and worldwide.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Scott, Aubrey D.; Pelmenschikov, Vladimir; Guo, Yisong
The properties of CO-inhibited Azotobacter vinelandii (Av) Mo-nitrogenase (N 2ase) have been examined by the combined application of nuclear resonance vibrational spectroscopy (NRVS), extended X-ray absorption fine structure (EXAFS), and density functional theory (DFT). Dramatic changes in the NRVS are seen under high-CO conditions, especially in a 188 cm –1 mode associated with symmetric breathing of the central cage of the FeMo-cofactor. Similar changes are reproduced with the α-H195Q N 2ase variant. In the frequency region above 450 cm –1, additional features are seen that are assigned to Fe-CO bending and stretching modes (confirmed by 13CO isotope shifts). The EXAFSmore » for wild-type N 2ase shows evidence for a significant cluster distortion under high-CO conditions, most dramatically in the splitting of the interaction between Mo and the shell of Fe atoms originally at 5.08 Å in the resting enzyme. A DFT model with both a terminal ₋CO and a partially reduced ₋CHO ligand bound to adjacent Fe sites is consistent with both earlier FT-IR experiments, and the present EXAFS and NRVS observations for the wild-type enzyme. Another DFT model with two terminal CO ligands on the adjacent Fe atoms yields Fe-CO bands consistent with the α-H195Q variant NRVS. The calculations also shed light on the vibrational “shake” modes of the interstitial atom inside the central cage, and their interaction with the Fe-CO modes. We discuss implications for the CO and N 2 reactivity of N 2ase.« less
Nuclear Resonance Vibrational Spectroscopic Definition of Peroxy Intermediates in Nonheme Iron Sites
Sutherlin, Kyle D.; Liu, Lei V.; Lee, Yong-Min; ...
2016-11-02
Fe III-(hydro)peroxy intermediates have been isolated in two classes of mononuclear nonheme Fe enzymes that are important in bioremediation: the Rieske dioxygenases and the extradiol dioxygenases. The binding mode and protonation state of the peroxide moieties in these intermediates are not well-defined, due to a lack of vibrational structural data. Nuclear resonance vibrational spectroscopy (NRVS) is an important technique for obtaining vibrational information on these and other intermediates, as it is sensitive to all normal modes with Fe displacement. Here in this paper, we present the NRVS spectra of side-on Fe III-peroxy and end-on Fe III-hydroperoxy model complexes and assignmore » these spectra using calibrated DFT calculations. We then use DFT calculations to define and understand the changes in the NRVS spectra that arise from protonation and from opening the Fe–O–O angle. This study identifies four spectroscopic handles that will enable definition of the binding mode and protonation state of Fe III-peroxy intermediates in mononuclear nonheme Fe enzymes. These structural differences are important in determining the frontier molecular orbitals available for reactivity.« less
Nuclear Resonance Vibrational Spectroscopic Definition of Peroxy Intermediates in Nonheme Iron Sites
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sutherlin, Kyle D.; Liu, Lei V.; Lee, Yong-Min
Fe III-(hydro)peroxy intermediates have been isolated in two classes of mononuclear nonheme Fe enzymes that are important in bioremediation: the Rieske dioxygenases and the extradiol dioxygenases. The binding mode and protonation state of the peroxide moieties in these intermediates are not well-defined, due to a lack of vibrational structural data. Nuclear resonance vibrational spectroscopy (NRVS) is an important technique for obtaining vibrational information on these and other intermediates, as it is sensitive to all normal modes with Fe displacement. Here in this paper, we present the NRVS spectra of side-on Fe III-peroxy and end-on Fe III-hydroperoxy model complexes and assignmore » these spectra using calibrated DFT calculations. We then use DFT calculations to define and understand the changes in the NRVS spectra that arise from protonation and from opening the Fe–O–O angle. This study identifies four spectroscopic handles that will enable definition of the binding mode and protonation state of Fe III-peroxy intermediates in mononuclear nonheme Fe enzymes. These structural differences are important in determining the frontier molecular orbitals available for reactivity.« less
Sutherlin, Kyle D; Liu, Lei V; Lee, Yong-Min; Kwak, Yeonju; Yoda, Yoshitaka; Saito, Makina; Kurokuzu, Masayuki; Kobayashi, Yasuhiro; Seto, Makoto; Que, Lawrence; Nam, Wonwoo; Solomon, Edward I
2016-11-02
Fe III -(hydro)peroxy intermediates have been isolated in two classes of mononuclear nonheme Fe enzymes that are important in bioremediation: the Rieske dioxygenases and the extradiol dioxygenases. The binding mode and protonation state of the peroxide moieties in these intermediates are not well-defined, due to a lack of vibrational structural data. Nuclear resonance vibrational spectroscopy (NRVS) is an important technique for obtaining vibrational information on these and other intermediates, as it is sensitive to all normal modes with Fe displacement. Here, we present the NRVS spectra of side-on Fe III -peroxy and end-on Fe III -hydroperoxy model complexes and assign these spectra using calibrated DFT calculations. We then use DFT calculations to define and understand the changes in the NRVS spectra that arise from protonation and from opening the Fe-O-O angle. This study identifies four spectroscopic handles that will enable definition of the binding mode and protonation state of Fe III -peroxy intermediates in mononuclear nonheme Fe enzymes. These structural differences are important in determining the frontier molecular orbitals available for reactivity.
Liu, Lei V.; Bell, Caleb B.; Wong, Shaun D.; Wilson, Samuel A.; Kwak, Yeonju; Chow, Marina S.; Zhao, Jiyong; Hodgson, Keith O.; Hedman, Britt; Solomon, Edward I.
2010-01-01
Bleomycin (BLM) is a glycopeptide anticancer drug capable of effecting single- and double-strand DNA cleavage. The last detectable intermediate prior to DNA cleavage is a low spin FeIII peroxy level species, termed activated bleomycin (ABLM). DNA strand scission is initiated through the abstraction of the C-4′ hydrogen atom of the deoxyribose sugar unit. Nuclear resonance vibrational spectroscopy (NRVS) aided by extended X-ray absorption fine structure spectroscopy and density functional theory (DFT) calculations are applied to define the natures of FeIIIBLM and ABLM as (BLM)FeIII─OH and (BLM)FeIII(η1─OOH) species, respectively. The NRVS spectra of FeIIIBLM and ABLM are strikingly different because in ABLM the δFe─O─O bending mode mixes with, and energetically splits, the doubly degenerate, intense O─Fe─Nax transaxial bends. DFT calculations of the reaction of ABLM with DNA, based on the species defined by the NRVS data, show that the direct H-atom abstraction by ABLM is thermodynamically favored over other proposed reaction pathways. PMID:21149675
Scott, Aubrey D.; Pelmenschikov, Vladimir; Guo, Yisong; ...
2014-10-02
The properties of CO-inhibited Azotobacter vinelandii (Av) Mo-nitrogenase (N 2ase) have been examined by the combined application of nuclear resonance vibrational spectroscopy (NRVS), extended X-ray absorption fine structure (EXAFS), and density functional theory (DFT). Dramatic changes in the NRVS are seen under high-CO conditions, especially in a 188 cm –1 mode associated with symmetric breathing of the central cage of the FeMo-cofactor. Similar changes are reproduced with the α-H195Q N 2ase variant. In the frequency region above 450 cm –1, additional features are seen that are assigned to Fe-CO bending and stretching modes (confirmed by 13CO isotope shifts). The EXAFSmore » for wild-type N 2ase shows evidence for a significant cluster distortion under high-CO conditions, most dramatically in the splitting of the interaction between Mo and the shell of Fe atoms originally at 5.08 Å in the resting enzyme. A DFT model with both a terminal ₋CO and a partially reduced ₋CHO ligand bound to adjacent Fe sites is consistent with both earlier FT-IR experiments, and the present EXAFS and NRVS observations for the wild-type enzyme. Another DFT model with two terminal CO ligands on the adjacent Fe atoms yields Fe-CO bands consistent with the α-H195Q variant NRVS. The calculations also shed light on the vibrational “shake” modes of the interstitial atom inside the central cage, and their interaction with the Fe-CO modes. We discuss implications for the CO and N 2 reactivity of N 2ase.« less
Scott, Aubrey D; Pelmenschikov, Vladimir; Guo, Yisong; Yan, Lifen; Wang, Hongxin; George, Simon J; Dapper, Christie H; Newton, William E; Yoda, Yoshitaka; Tanaka, Yoshihito; Cramer, Stephen P
2014-11-12
The properties of CO-inhibited Azotobacter vinelandii (Av) Mo-nitrogenase (N2ase) have been examined by the combined application of nuclear resonance vibrational spectroscopy (NRVS), extended X-ray absorption fine structure (EXAFS), and density functional theory (DFT). Dramatic changes in the NRVS are seen under high-CO conditions, especially in a 188 cm(-1) mode associated with symmetric breathing of the central cage of the FeMo-cofactor. Similar changes are reproduced with the α-H195Q N2ase variant. In the frequency region above 450 cm(-1), additional features are seen that are assigned to Fe-CO bending and stretching modes (confirmed by (13)CO isotope shifts). The EXAFS for wild-type N2ase shows evidence for a significant cluster distortion under high-CO conditions, most dramatically in the splitting of the interaction between Mo and the shell of Fe atoms originally at 5.08 Å in the resting enzyme. A DFT model with both a terminal -CO and a partially reduced -CHO ligand bound to adjacent Fe sites is consistent with both earlier FT-IR experiments, and the present EXAFS and NRVS observations for the wild-type enzyme. Another DFT model with two terminal CO ligands on the adjacent Fe atoms yields Fe-CO bands consistent with the α-H195Q variant NRVS. The calculations also shed light on the vibrational "shake" modes of the interstitial atom inside the central cage, and their interaction with the Fe-CO modes. Implications for the CO and N2 reactivity of N2ase are discussed.
Chow, Chi-Wai; Shiu, Ruei-Jie; Liu, Yen-Chun; Liao, Xin-Lan; Lin, Kun-Hsien; Wang, Yi-Chang; Chen, Yi-Yuan
2018-05-14
A frequency-shift-keying (FSK) visible light communication (VLC) system is proposed and demonstrated using advertisement light-panel as transmitter and mobile-phone image sensor as receiver. The developed application program (APP) in mobile-phone can retrieve the rolling shutter effect (RSE) pattern produced by the FSK VLC signal effectively. Here, we also define noise-ratio value (NRV) to evaluate the contrast of different advertisements displayed on the light-panel. Both mobile-phones under test can achieve success rate > 96% even when the transmission distance is up to 200 cm and the NRVs are low.
Comprehensive Fe-ligand vibration identification in {FeNO} 6 Hemes
Li, Jianfeng; Peng, Qian; Oliver, Allen G.; ...
2014-12-09
Oriented single-crystal nuclear resonance vibrational spectroscopy (NRVS) has been used to obtain all iron vibrations in two {FeNO} 6 porphyrinate complexes, five-coordinate [Fe(OEP)(NO)]ClO 4 and six-coordinate [Fe(OEP)(2-MeHIm)(NO)]ClO 4. A new crystal structure was required for measurements of [Fe(OEP)(2-MeHIm)(NO)]ClO 4, and the new structure is reported herein. Single crystals of both complexes were oriented to be either parallel or perpendicular to the porphyrin plane and/or axial imidazole ligand plane. Thus, the FeNO bending and stretching modes can now be unambiguously assigned; the pattern of shifts in frequency as a function of coordination number can also be determined. The pattern is quitemore » distinct from those found for CO or {FeNO} 7 heme species. This is the result of unchanging Fe–N NO bonding interactions in the {FeNO} 6 species, in distinct contrast to the other diatomic ligand species. DFT calculations were also used to obtain detailed predictions of vibrational modes. Predictions were consistent with the intensity and character found in the experimental spectra. The NRVS data allow the assignment and observation of the challenging to obtain Fe–Im stretch in six-coordinate heme derivatives. Furthermore, NRVS data for this and related six-coordinate hemes with the diatomic ligands CO, NO, and O 2 reveal a strong correlation between the Fe–Im stretch and Fe–N Im bond distance that is detailed for the first time.« less
Elucidation of the iron(IV)–oxo intermediate in the non-haem iron halogenase SyrB2
Wong, Shaun D.; Srnec, Martin; Matthews, Megan L.; Liu, Lei V.; Kwak, Yeonju; Park, Kiyoung; Bell, Caleb B.; Alp, E. Ercan; Zhao, Jiyong; Yoda, Yoshitaka; Kitao, Shinji; Seto, Makoto; Krebs, Carsten; Bollinger, J. Martin; Solomon, Edward I.
2013-01-01
SUMMARY Mononuclear non-haem iron (NHFe) enzymes catalyse a wide variety of oxidative reactions including halogenation, hydroxylation, ring closure, desaturation, and aromatic ring cleavage. These are highly important for mammalian somatic processes such as phenylalanine metabolism, production of neurotransmitters, hypoxic response, and the biosynthesis of natural products.1–3 The key reactive intermediate in the catalytic cycles of these enzymes is an S = 2 FeIV=O species, which has been trapped for a number of NHFe enzymes4–8 including the halogenase SyrB2, the subject of this study. Computational studies to understand the reactivity of the enzymatic NHFe FeIV=O intermediate9–13 are limited in applicability due to the paucity of experimental knowledge regarding its geometric and electronic structures, which determine its reactivity. Synchrotron-based nuclear resonance vibrational spectroscopy (NRVS) is a sensitive and effective method that defines the dependence of the vibrational modes of Fe on the nature of the FeIV=O active site.14–16 Here we present the first NRVS structural characterisation of the reactive FeIV=O intermediate of a NHFe enzyme. This FeIV=O intermediate reacts via an initial H-atom abstraction step, with its subsquent halogenation (native) or hydroxylation (non-native) rebound reactivity being dependent on the substrate.17 A correlation of the experimental NRVS data to electronic structure calculations indicates that the substrate is able to direct the orientation of the FeIV=O intermediate, presenting specific frontier molecular orbitals (FMOs) which can activate the selective halogenation versus hydroxylation reactivity. PMID:23868262
Lauterbach, Lars; Wang, Hongxin; Horch, Marius; ...
2014-10-30
Hydrogenases are complex metalloenzymes that catalyze the reversible splitting of molecular hydrogen into protons and electrons essentially without overpotential. The NAD+-reducing soluble hydrogenase (SH) from Ralstonia eutropha is capable of H 2 conversion even in the presence of usually toxic dioxygen. The molecular details of the underlying reactions are largely unknown, mainly because of limited knowledge of the structure and function of the various metal cofactors present in the enzyme. Here, all iron-containing cofactors of the SH were investigated by 57Fe specific nuclear resonance vibrational spectroscopy (NRVS). Our data provide experimental evidence for one [2Fe2S] center and four [4Fe4S] clusters,more » which is consistent with the amino acid sequence composition. Only the [2Fe2S] cluster and one of the four [4Fe4S] clusters were reduced upon incubation of the SH with NADH. This finding explains the discrepancy between the large number of FeS clusters and the small amount of FeS cluster-related signals as detected by electron paramagnetic resonance spectroscopic analysis of several NAD+-reducing hydrogenases. For the first time, Fe–CO and Fe–CN modes derived from the [NiFe] active site could be distinguished by NRVS through selective 13C labeling of the CO ligand. This strategy also revealed the molecular coordinates that dominate the individual Fe–CO modes. The present approach explores the complex vibrational signature of the Fe–S clusters and the hydrogenase active site, thereby showing that NRVS represents a powerful tool for the elucidation of complex biocatalysts containing multiple cofactors.« less
Lauterbach, Lars; Wang, Hongxin; Horch, Marius; Gee, Leland B; Yoda, Yoshitaka; Tanaka, Yoshihito; Zebger, Ingo; Lenz, Oliver; Cramer, Stephen P
Hydrogenases are complex metalloenzymes that catalyze the reversible splitting of molecular hydrogen into protons and electrons essentially without overpotential. The NAD + -reducing soluble hydrogenase (SH) from Ralstonia eutropha is capable of H 2 conversion even in the presence of usually toxic dioxygen. The molecular details of the underlying reactions are largely unknown, mainly because of limited knowledge of the structure and function the various metal cofactors present in the enzyme. Here all iron-containing cofactors of the SH were investigated by 57 Fe specific nuclear resonance vibrational spectroscopy (NRVS). Our data provide experimental evidence for one [2Fe2S] center and four [4Fe4S] clusters, which is consistent with amino acid sequence composition. Only the [2Fe2S] cluster and one of the four [4Fe4S] clusters were reduced upon incubation of the SH with NADH. This finding explains the discrepancy between the large number of FeS clusters and the small amount of FeS cluster-related signals as detected by electron paramagnetic resonance spectroscopic analysis of several NAD + -reducing hydrogenases. For the first time, Fe-CO and Fe-CN modes derived from the [NiFe] active site could be distinguished by NRVS through selective 13 C labeling of the CO ligand. This strategy also revealed the molecular coordinates that dominate the individual Fe-CO modes. The present approach explores the complex vibrational signature of the Fe-S clusters and the hydrogenase active site, thereby showing that NRVS represents a powerful tool for the elucidation of complex biocatalysts containing multiple cofactors.
Pelmenschikov, Vladimir; Guo, Yisong; Wang, Hongxin; Cramer, Stephen P.; Case, David A.
2010-01-01
Infrared, Raman, and nuclear resonant vibrational (NRVS) spectroscopies have been used to address the Fe-H bonding in trans-Fe(H)(CO) iron hydride compound, Fe(H)(CO)(dppe)2, dppe = 1,2-bis(diphenylphosphino)ethane. H and D isotopomers of the compound, with the selective substitution at the metal-coordinated hydrogen, have been considered in order to address the Fe-H/D stretching and bending modes. Experimental results are compared to the normal mode analysis by the density functional theory (DFT). The results are that (i) the IR spectrum does not clearly show Fe–H stretching or bending modes; (ii) Fe–H stretching modes are clear but weak in the Raman spectrum, and Fe–H bending modes are weak; (iii) NRVS 57Fe spectroscopy resolves Fe-H bending clearly, but Fe–H or Fe–D stretching is above its experimentally resolved frequency range. DFT caclulations (with no scaling of frequencies) show intensities and peak locations that allow unambigous correlations between observed and calculated features, with frequency errors generally less than 15 cm−1. Prospects for using these techniques to unravel vibrational modes of protein active sites are discussed. PMID:21322496
DOE Office of Scientific and Technical Information (OSTI.GOV)
Serrano, Pauline N.; Wang, Hongxin; Crack, Jason C.
The reaction of protein-bound iron–sulfur (Fe-S) clusters with nitric oxide (NO) plays key roles in NO-mediated toxicity and signaling. Elucidation of the mechanism of the reaction of NO with DNA regulatory proteins that contain Fe-S clusters has been hampered by a lack of information about the nature of the iron-nitrosyl products formed. Herein, we report nuclear resonance vibrational spectroscopy (NRVS) and density functional theory (DFT) calculations that identify NO reaction products in WhiD and NsrR, regulatory proteins that use a [4Fe-4S] cluster to sense NO. This work reveals that nitrosylation yields multiple products structurally related to Roussin's Red Ester (RRE,more » [Fe 2(NO) 4(Cys) 2]) and Roussin's Black Salt (RBS, [Fe 4(NO) 7S 3]. In the latter case, the absence of 32S/ 34S shifts in the Fe-S region of the NRVS spectra suggest that a new species, Roussin's Black Ester (RBE), may be formed, in which one or more of the sulfide ligands is replaced by Cys thiolates.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Arjmand, F.; Sharma, S.; Usman, M.
2016-06-21
The vibrational dynamics of a newly synthesized tetrastannoxane was characterized with a combination of experimental (Raman, IR and tin-based nuclear resonance vibrational spectroscopy) and computational (DFT/B3LYP) methods, with an emphasis on the vibrations of the tin sites. The cytotoxic activity revealed a significant regression selectively against the human pancreatic cell lines.
Reaction intermediates in the catalytic Gif-type oxidation from nuclear inelastic scattering
NASA Astrophysics Data System (ADS)
Rajagopalan, S.; Asthalter, T.; Rabe, V.; Laschat, S.
2016-12-01
Nuclear inelastic scattering (NIS) of synchrotron radiation, also known as nuclear resonant vibrational spectroscopy (NRVS), has been shown to provide valuable insights into metal-centered vibrations at Mössbauer-active nuclei. We present a study of the iron-centered vibrational density of states (VDOS) during the first step of the Gif-type oxidation of cyclohexene with a novel trinuclear Fe3(μ 3-O) complex as catalyst precursor. The experiments were carried out on shock-frozen solutions for different combinations of reactants: Fe3(μ 3-O) in pyridine solution, Fe3(μ 3-O) plus Zn/acetic acid in pyridine without and with addition of either oxygen or cyclohexene, and Fe3(μ 3-O)/Zn/acetic acid/pyridine/cyclohexene (reaction mixture) for reaction times of 1 min, 5 min, and 30 min. The projected VDOS of the Fe atoms was calculated on the basis of pseudopotential density functional calculations. Two possible reaction intermediates were identified as [Fe(III)(C5H5N)2(O2CCH3)2]+ and Fe(II)(C5H5N)4(O2CCH3)2, yielding evidence that NIS (NRVS) allows to identify the presence of iron-centered intermediates also in complex reaction mixtures.
Nutrient reference value: non-communicable disease endpoints--a conference report.
Lupton, J R; Blumberg, J B; L'Abbe, M; LeDoux, M; Rice, H B; von Schacky, C; Yaktine, A; Griffiths, J C
2016-03-01
Nutrition is complex-and seemingly getting more complicated. Most consumers are familiar with "essential nutrients," e.g., vitamins and minerals, and more recently protein and important amino acids. These essential nutrients have nutrient reference values, referred to as dietary reference intakes (DRIs) developed by consensus committees of scientific experts convened by the Institute of Medicine of the National Academy of Sciences, Engineering, and Medicine and carried out by the Food and Nutrition Board. The DRIs comprise a set of four nutrient-based reverence values, the estimated average requirements, the recommended dietary allowances (RDAs), the adequate intakes and the tolerable upper intake levels for micronutrient intakes and an acceptable macronutrient distribution range for macronutrient intakes. From the RDA, the US Food and Drug Administration (FDA) derives a labeling value called the daily value (DV), which appears on the nutrition label of all foods for sale in the US. The DRI reports do not make recommendations about whether the DV labeling values can be set only for what have been defined to date as "essential nutrients." For example, the FDA set a labeling value for "dietary fiber" without having the DV. Nutrient reference values-requirements are set by Codex Alimentarius for essential nutrients, and regulatory bodies in many countries use these Codex values in setting national policy for recommended dietary intakes. However, the focus of this conference is not on essential nutrients, but on the "nonessential nutrients," also termed dietary bioactive components. They can be defined as "Constituents in foods or dietary supplements, other than those needed to meet basic human nutritional needs, which are responsible for changes in health status (Office of Disease Prevention and Health Promotion, Office of Public Health and Science, Department of Health and Human Services in Fed Regist 69:55821-55822, 2004)." Substantial and often persuasive scientific evidence does exist to confirm a relationship between the intake of a specific bioactive constituent and enhanced health conditions or reduced risk of a chronic disease. Further, research on the putative mechanisms of action of various classes of bioactives is supported by national and pan-national government agencies, and academic institutions, as well as functional food and dietary supplement manufacturers. Consumers are becoming educated and are seeking to purchase products containing bioactives, yet there is no evaluative process in place to let the public know how strong the science is behind the benefits or the quantitative amounts needed to achieve these beneficial health effects or to avoid exceeding the upper level (UL). When one lacks an essential nutrient, overt deficiency with concomitant physiological determents and eventually death are expected. The absence of bioactive substances from the diet results in suboptimal health, e.g., poor cellular and/or physiological function, which is relative and not absolute. Regrettably at this time, there is no DRI process to evaluate bioactives, although a recent workshop convened by the National Institutes of Health (Options for Consideration of Chronic Disease Endpoints for Dietary Reference Intakes (DRIs); March 10-11, 2015; http://health.gov/dietaryguidelines/dri/ ) did explore the process to develop DVs for nutrients, the lack of which result in increased risk of chronic disease (non-communicable disease) endpoints. A final report is expected soon. This conference (CRN-International Scientific Symposium; "Nutrient Reference Value-Non-Communicable Disease (NRV-NCD) Endpoints," 20 November in Kronberg, Germany; http://www.crn-i.ch/2015symposium/ ) explores concepts related to the Codex NRV process, the public health opportunities in setting NRVs for bioactive constituents, and further research and details on the specific class of bioactives, n-3 long-chain polyunsaturated fatty acids (also termed omega-3 fatty acids) and their constituents, specifically docosahexaenoic acid and eicosapentaenoic acid.
Symstad, Amy J.; Jonas, Jayne L.; Edited by Guntenspergen, Glenn R.
2014-01-01
Natural range of variation (NRV) may be used to establish decision thresholds or action assessment points when ecological thresholds are either unknown or do not exist for attributes of interest in a managed ecosystem. The process for estimating NRV involves identifying spatial and temporal scales that adequately capture the heterogeneity of the ecosystem; compiling data for the attributes of interest via study of historic records, analysis and interpretation of proxy records, modeling, space-for-time substitutions, or analysis of long-term monitoring data; and quantifying the NRV from those data. At least 19 National Park Service (NPS) units in North America’s Great Plains are monitoring plant species richness and evenness as indicators of vegetation integrity in native grasslands, but little information on natural, temporal variability of these indicators is available. In this case study, we use six long-term vegetation monitoring datasets to quantify the temporal variability of these attributes in reference conditions for a variety of Great Plains grassland types, and then illustrate the implications of using different NRVs based on these quantities for setting management decision thresholds. Temporal variability of richness (as measured by the coefficient of variation, CV) is fairly consistent across the wide variety of conditions occurring in Colorado shortgrass prairie to Minnesota tallgrass sand savanna (CV 0.20–0.45) and generally less than that of production at the same sites. Temporal variability of evenness spans a greater range of CV than richness, and it is greater than that of production in some sites but less in other sites. This natural temporal variability may mask undesirable changes in Great Plains grasslands vegetation. Consequently, we suggest that managers consider using a relatively narrow NRV (interquartile range of all richness or evenness values observed in reference conditions) for designating a surveillance threshold, at which greater attention to the situation would be paid, and a broader NRV for designating management thresholds, at which action would be instigated.
Effects of Protein Structure on Iron–Polypeptide Vibrational Dynamic Coupling in Cytochrome c
Galinato, Mary Grace I.; Bowman, Sarah E. J.; Kleingardner, Jesse G.; ...
2014-12-22
Cytochrome c (Cyt c) has a heme covalently bound to the polypeptide via a Cys-X-X-Cys-His (CXXCH) linker that is located in the interface region for protein–protein interactions. To determine whether the polypeptide matrix influences iron vibrational dynamics, nuclear resonance vibrational spectroscopy (NRVS) measurements were performed on 57Fe-labeled ferric Hydrogenobacter thermophilus cytochrome c-552, and variants M13V, M13V/K22M, and A7F, which have structural modifications that alter the composition or environment of the CXXCH pentapeptide loop. Simulations of the NRVS data indicate that the 150–325 cm –1 region is dominated by N His–Fe–S Met axial ligand and polypeptide motions, while the 325–400 cmmore » –1 region shows dominant contributions from ν(Fe–N Pyr) (Pyr = pyrrole) and other heme-based modes. Diagnostic spectral signatures that directly relate to structural features of the heme active site are identified using a quantum chemistry-centered normal coordinate analysis (QCC-NCA). In particular, spectral features that directly correlate with CXXCH loop stiffness, the strength of the Fe–His interaction, and the degree of heme distortion are identified. Cumulative results from our investigation suggest that compared to the wild type (wt), variants M13V and M13V/K22M have a more rigid CXXCH pentapeptide segment, a stronger Fe–N His interaction, and a more ruffled heme. Conversely, the A7F variant has a more planar heme and a weaker Fe–NHis bond. These results are correlated to the observed changes in reduction potential between wt protein and the variants studied here. Lastly, we discuss the implications of these results for Cyt c biogenesis and electron transfer.« less
Effects of Protein Structure on Iron–Polypeptide Vibrational Dynamic Coupling in Cytochrome c
2015-01-01
Cytochrome c (Cyt c) has a heme covalently bound to the polypeptide via a Cys-X-X-Cys-His (CXXCH) linker that is located in the interface region for protein–protein interactions. To determine whether the polypeptide matrix influences iron vibrational dynamics, nuclear resonance vibrational spectroscopy (NRVS) measurements were performed on 57Fe-labeled ferric Hydrogenobacter thermophilus cytochrome c-552, and variants M13V, M13V/K22M, and A7F, which have structural modifications that alter the composition or environment of the CXXCH pentapeptide loop. Simulations of the NRVS data indicate that the 150–325 cm–1 region is dominated by NHis–Fe–SMet axial ligand and polypeptide motions, while the 325–400 cm–1 region shows dominant contributions from ν(Fe–NPyr) (Pyr = pyrrole) and other heme-based modes. Diagnostic spectral signatures that directly relate to structural features of the heme active site are identified using a quantum chemistry-centered normal coordinate analysis (QCC-NCA). In particular, spectral features that directly correlate with CXXCH loop stiffness, the strength of the Fe–His interaction, and the degree of heme distortion are identified. Cumulative results from our investigation suggest that compared to the wild type (wt), variants M13V and M13V/K22M have a more rigid CXXCH pentapeptide segment, a stronger Fe–NHis interaction, and a more ruffled heme. Conversely, the A7F variant has a more planar heme and a weaker Fe–NHis bond. These results are correlated to the observed changes in reduction potential between wt protein and the variants studied here. Implications of these results for Cyt c biogenesis and electron transfer are also discussed. PMID:25531247
DOE Office of Scientific and Technical Information (OSTI.GOV)
O'Dowd, Bing; Williams, Sarah; Wang, Hongxin
Isoprenoid biosynthesis is an important area for anti-infective drug development. One isoprenoid target described is (E)-1-hydroxy-2-methyl-but-2-enyl 4-diphosphate (HMBPP) reductase (IspH), which forms isopentenyl diphosphate and dimethylallyl diphosphate from HMBPP in a 2H + /2e - reduction. IspH contains a 4 Fe-4 S cluster, and in this work, we first investigated how small molecules bound to the cluster by using HYSCORE and NRVS spectroscopies. The results of these, as well as other structural and spectroscopic investigations, led to the conclusion that, in most cases, ligands bound to IspH 4 Fe-4 S clusters by η 1 coordination, forming tetrahedral geometries at themore » unique fourth Fe, ligand side chains preventing further ligand (e.g., H 2 O, O 2 ) binding. Based on these ideas, we used in silico methods to find drug-like inhibitors that might occupy the HMBPP substrate binding pocket and bind to Fe, leading to the discovery of a barbituric acid analogue with a K i value of ≈500 nm against Pseudomonas aeruginosa IspH.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Peng, Qian; Pavlik, Jeffrey W.; Silvernail, Nathan J.
The vibrational spectrum of a six-coordinate nitrosyl iron porphyrinate, monoclinic [Fe(T pFPP)(1-MeIm)(NO)] (T pFPP = tetra- para-fluorophenylporphyrin; 1-MeIm=1-methylimidazole), has been studied by oriented single-crystal nuclear resonance vibrational spectroscopy (NRVS). The crystal was oriented to give spectra perpendicular to the porphyrin plane and two in-plane spectra perpendicular or parallel to the projection of the FeNO plane. These enable assignment of the FeNO bending and stretching modes. The measurements reveal that the two in-plane spectra have substantial differences that result from the strongly bonded axial NO ligand. The direction of the in-plane iron motion is found to be largely parallel and perpendicularmore » to the projection of the bent FeNO on the porphyrin plane. The out-of-plane Fe-N-O stretching and bending modes are strongly mixed with each other, as well as with porphyrin ligand modes. The stretch is mixed with v 50 as was also observed for dioxygen complexes. The frequency of the assigned stretching mode of eight Fe-X-O (X= N, C, and O) complexes is correlated with the Fe XO bond lengths. The nature of highest frequency band at ≈560 cm -1 has also been examined in two additional new derivatives. Previously assigned as the Fe NO stretch (by resonance Raman), it is better described as the bend, as the motion of the central nitrogen atom of the FeNO group is very large. There is significant mixing of this mode. In conclusion, the results emphasize the importance of mode mixing; the extent of mixing must be related to the peripheral phenyl substituents.« less
Peng, Qian; Pavlik, Jeffrey W.; Silvernail, Nathan J.; ...
2016-03-21
The vibrational spectrum of a six-coordinate nitrosyl iron porphyrinate, monoclinic [Fe(T pFPP)(1-MeIm)(NO)] (T pFPP = tetra- para-fluorophenylporphyrin; 1-MeIm=1-methylimidazole), has been studied by oriented single-crystal nuclear resonance vibrational spectroscopy (NRVS). The crystal was oriented to give spectra perpendicular to the porphyrin plane and two in-plane spectra perpendicular or parallel to the projection of the FeNO plane. These enable assignment of the FeNO bending and stretching modes. The measurements reveal that the two in-plane spectra have substantial differences that result from the strongly bonded axial NO ligand. The direction of the in-plane iron motion is found to be largely parallel and perpendicularmore » to the projection of the bent FeNO on the porphyrin plane. The out-of-plane Fe-N-O stretching and bending modes are strongly mixed with each other, as well as with porphyrin ligand modes. The stretch is mixed with v 50 as was also observed for dioxygen complexes. The frequency of the assigned stretching mode of eight Fe-X-O (X= N, C, and O) complexes is correlated with the Fe XO bond lengths. The nature of highest frequency band at ≈560 cm -1 has also been examined in two additional new derivatives. Previously assigned as the Fe NO stretch (by resonance Raman), it is better described as the bend, as the motion of the central nitrogen atom of the FeNO group is very large. There is significant mixing of this mode. In conclusion, the results emphasize the importance of mode mixing; the extent of mixing must be related to the peripheral phenyl substituents.« less
Vibrational Dynamics of Biological Molecules: Multi-quantum Contributions
Leu, Bogdan M.; Timothy Sage, J.; Zgierski, Marek Z.; Wyllie, Graeme R. A.; Ellison, Mary K.; Robert Scheidt, W.; Sturhahn, Wolfgang; Ercan Alp, E.; Durbin, Stephen M.
2006-01-01
High-resolution X-ray measurements near a nuclear resonance reveal the complete vibrational spectrum of the probe nucleus. Because of this, nuclear resonance vibrational spectroscopy (NRVS) is a uniquely quantitative probe of the vibrational dynamics of reactive iron sites in proteins and other complex molecules. Our measurements of vibrational fundamentals have revealed both frequencies and amplitudes of 57Fe vibrations in proteins and model compounds. Information on the direction of Fe motion has also been obtained from measurements on oriented single crystals, and provides an essential test of normal mode predictions. Here, we report the observation of weaker two-quantum vibrational excitations (overtones and combinations) for compounds that mimic the active site of heme proteins. The predicted intensities depend strongly on the direction of Fe motion. We compare the observed features with predictions based on the observed fundamentals, using information on the direction of Fe motion obtained either from DFT predictions or from single crystal measurements. Two-quantum excitations may become a useful tool to identify the directions of the Fe oscillations when single crystals are not available. PMID:16894397
[Geographical distribution of the Serum creatinine reference values of healthy adults].
Wei, De-Zhi; Ge, Miao; Wang, Cong-Xia; Lin, Qian-Yi; Li, Meng-Jiao; Li, Peng
2016-11-20
To explore the relationship between serum creatinine (Scr) reference values in healthy adults and geographic factors and provide evidence for establishing Scr reference values in different regions. We collected 29 697 Scr reference values from healthy adults measured by 347 medical facilities from 23 provinces, 4 municipalities and 5 autonomous regions. We chose 23 geographical factors and analyzed their correlation with Scr reference values to identify the factors correlated significantly with Scr reference values. According to the Principal component analysis and Ridge regression analysis, two predictive models were constructed and the optimal model was chosen after comparison of the two model's fitting degree of predicted results and measured results. The distribution map of Scr reference values was drawn using the Kriging interpolation method. Seven geographic factors, including latitude, annual sunshine duration, annual average temperature, annual average relative humidity, annual precipitation, annual temperature range and topsoil (silt) cation exchange capacity were found to correlate significantly with Scr reference values. The overall distribution of Scr reference values featured a pattern that the values were high in the south and low in the north, varying consistently with the latitude change. The data of the geographic factors in a given region allows the prediction of the Scr values in healthy adults. Analysis of these geographical factors can facilitate the determination of the reference values specific to a region to improve the accuracy for clinical diagnoses.
Predictive value and efficiency of laboratory testing.
Galen, R S
1980-11-01
Literature on determining reference values and reference intervals on "normal" or "healthy" individuals is abundant. It is impossible, however, to evaluate a data set of reference values and select a suitable reference interval that will be meaningful for the practice of medicine. The reference interval, no matter how derived statistically, tells us nothing about disease. This is the main reason the concepts of "normal values" have failed us and why "reference values" will prove similarly disappointing. By studying these same constituents in a variety of disease states as well, it will be possible to select "referent values" that will make the test procedure meaningful for diagnostic purposes. In order to obtain meaningful referent values for predicting disease, it is necessary to study not only the "healthy" reference population, but patients with the disease in question, and patients who are free of the disease in question but who have other diseases. Studies of this type are not frequently found for laboratory tests that are in common use today.
Reference values of thirty-one frequently used laboratory markers for 75-year-old males and females
Ryden, Ingvar; Lind, Lars
2012-01-01
Background We have previously reported reference values for common clinical chemistry tests in healthy 70-year-old males and females. We have now repeated this study 5 years later to establish reference values also at the age of 75. It is important to have adequate reference values for elderly patients as biological markers may change over time, and adequate reference values are essential for correct clinical decisions. Methods We have investigated 31 frequently used laboratory markers in 75-year-old males (n = 354) and females (n = 373) without diabetes. The 2.5 and 97.5 percentiles for these markers were calculated according to the recommendations of the International Federation of Clinical Chemistry. Results Reference values are reported for 75-year-old males and females for 31 frequently used laboratory markers. Conclusion There were minor differences between reference intervals calculated with and without individuals with cardiovascular diseases. Several of the reference intervals differed from Scandinavian reference intervals based on younger individuals (Nordic Reference Interval Project). PMID:22300333
Reference Values for Cardiorespiratory Fitness and Incidence of Type 2 Diabetes
Kawakami, Ryoko; Sawada, Susumu S.; Matsushita, Munehiro; Okamoto, Takashi; Tsukamoto, Koji; Higuchi, Mitsuru; Miyachi, Motohiko
2014-01-01
Background In “Physical Activity Reference for Health Promotion 2013” the Japan Ministry of Health, Labour and Welfare publication gives reference values for cardiorespiratory fitness (CRF) required for good health. We examined the associations between the CRF reference values and incidence of type 2 diabetes. Methods This prospective cohort study enrolled 4633 nondiabetic Japanese men aged 20 to 39 years at baseline. CRF was measured using the cycle ergometer test, and maximal oxygen uptake was estimated. On the basis of the CRF reference value, participants were classified into 2 groups: those with values less than the reference value (under-RV) and those with values equal to or greater than reference value (over-RV). Hazard ratios (HRs) and 95% CIs for incident type 2 diabetes were estimated using a Cox proportional hazards model. Results A total of 266 participants developed type 2 diabetes during the 14 years of follow-up. As compared with the under-RV group, the over-RV group had a significantly lower multivariable-adjusted HR for type 2 diabetes (HR 0.67; 95% CI, 0.51–0.89). In receiver operating characteristic analysis, the optimal CRF cut-off value for predicting incident type 2 diabetes was 10.8 metabolic equivalents (sensitivity, 0.64; specificity, 0.64), which was close to the CRF reference value of 11.0 metabolic equivalents. Conclusions The reference CRF value appears to be reasonably valid for prevention of type 2 diabetes, especially among Japanese men younger than 40 years. Development of type 2 diabetes can be prevented by maintaining a CRF level above the reference value. PMID:24240630
Makretsov, Nikita; Gilks, C Blake; Alaghehbandan, Reza; Garratt, John; Quenneville, Louise; Mercer, Joel; Palavdzic, Dragana; Torlakovic, Emina E
2011-07-01
External quality assurance and proficiency testing programs for breast cancer predictive biomarkers are based largely on traditional ad hoc design; at present there is no universal consensus on definition of a standard reference value for samples used in external quality assurance programs. To explore reference values for estrogen receptor and progesterone receptor immunohistochemistry in order to develop an evidence-based analytic platform for external quality assurance. There were 31 participating laboratories, 4 of which were previously designated as "expert" laboratories. Each participant tested a tissue microarray slide with 44 breast carcinomas for estrogen receptor and progesterone receptor and submitted it to the Canadian Immunohistochemistry Quality Control Program for analysis. Nuclear staining in 1% or more of the tumor cells was a positive score. Five methods for determining reference values were compared. All reference values showed 100% agreement for estrogen receptor and progesterone receptor scores, when indeterminate results were excluded. Individual laboratory performance (agreement rates, test sensitivity, test specificity, positive predictive value, negative predictive value, and κ value) was very similar for all reference values. Identification of suboptimal performance by all methods was identical for 30 of 31 laboratories. Estrogen receptor assessment of 1 laboratory was discordant: agreement was less than 90% for 3 of 5 reference values and greater than 90% with the use of 2 other reference values. Various reference values provide equivalent laboratory rating. In addition to descriptive feedback, our approach allows calculation of technical test sensitivity and specificity, positive and negative predictive values, agreement rates, and κ values to guide corrective actions.
The Neurobiology of Reference-Dependent Value Computation
De Martino, Benedetto; Kumaran, Dharshan; Holt, Beatrice; Dolan, Raymond J.
2009-01-01
A key focus of current research in neuroeconomics concerns how the human brain computes value. Although, value has generally been viewed as an absolute measure (e.g., expected value, reward magnitude), much evidence suggests that value is more often computed with respect to a changing reference point, rather than in isolation. Here, we present the results of a study aimed to dissociate brain regions involved in reference-independent (i.e., “absolute”) value computations, from those involved in value computations relative to a reference point. During functional magnetic resonance imaging, subjects acted as buyers and sellers during a market exchange of lottery tickets. At a behavioral level, we demonstrate that subjects systematically accorded a higher value to objects they owned relative to those they did not, an effect that results from a shift in reference point (i.e., status quo bias or endowment effect). Our results show that activity in orbitofrontal cortex and dorsal striatum track parameters such as the expected value of lottery tickets indicating the computation of reference-independent value. In contrast, activity in ventral striatum indexed the degree to which stated prices, at a within-subjects and between-subjects level, were distorted with respect to a reference point. The findings speak to the neurobiological underpinnings of reference dependency during real market value computations. PMID:19321780
Reference values for 27 clinical chemistry tests in 70-year-old males and females.
Carlsson, Lena; Lind, Lars; Larsson, Anders
2010-01-01
Reference values are usually defined based on blood samples from healthy men or nonpregnant women in the age range of 20-50 years. These values are not optimal for elderly patients, as many biological markers change over time and adequate reference values are important for correct clinical decisions. To validate NORIP (Nordic Reference Interval Project) reference values in a 70-year-old population. We studied 27 frequently used laboratory tests. The 2.5th and 97.5th percentiles for these markers were calculated according to the recommendations of the International Federation of Clinical Chemistry on the statistical treatment of reference values. Reference values are reported for plasma alanine aminotransferase, albumin, alkaline phosphatase, pancreas amylase, apolipoprotein A1, apolipoprotein B, aspartate aminotransferase, bilirubin, calcium, chloride, cholesterol, creatinine, creatine kinase, C-reactive protein, glucose, gamma-glutamyltransferase, HDL-cholesterol, iron, lactate dehydrogenase, LDL-cholesterol, magnesium, phosphate, potassium, sodium, transferrin, triglycerides, urate and urea. Reference values calculated from the whole population and a subpopulation without cardiovascular disease showed strong concordance. Several of the reference interval limits were outside the 90% CI of a Scandinavian population (NORIP). 2009 S. Karger AG, Basel.
Validated age-specific reference values for CSF total protein levels in children.
Kahlmann, V; Roodbol, J; van Leeuwen, N; Ramakers, C R B; van Pelt, D; Neuteboom, R F; Catsman-Berrevoets, C E; de Wit, M C Y; Jacobs, B C
2017-07-01
To define age-specific reference values for cerebrospinal fluid (CSF) total protein levels for children and validate these values in children with Guillain-Barré syndrome (GBS), acute disseminated encephalomyelitis (ADEM) and multiple sclerosis (MS). Reference values for CSF total protein levels were determined in an extensive cohort of diagnostic samples from children (<18 year) evaluated at Erasmus Medical Center/Sophia Children's Hospital. These reference values were confirmed in children diagnosed with disorders unrelated to raised CSF total protein level and validated in children with GBS, ADEM and MS. The test results of 6145 diagnostic CSF samples from 3623 children were used to define reference values. The reference values based on the upper limit of the 95% CI (i.e. upper limit of normal) were for 6 months-2 years 0.25 g/L, 2-6 years 0.25 g/L, 6-12 years 0.28 g/L, 12-18 years 0.34 g/L. These reference values were confirmed in a subgroup of 378 children diagnosed with disorders that are not typically associated with increased CSF total protein. In addition, the CSF total protein levels in these children in the first 6 months after birth were highly variable (median 0.47 g/L, IQR 0.26-0.65). According to these new reference values, CSF total protein level was elevated in 85% of children with GBS, 66% with ADEM and 23% with MS. More accurate age-specific reference values for CSF total protein levels in children were determined. These new reference values are more sensitive than currently used values for diagnosing GBS and ADEM in children. Copyright © 2017 European Paediatric Neurology Society. Published by Elsevier Ltd. All rights reserved.
2013-01-01
Background The measurement of the Erythrocyte Sedimentation Rate (ESR) value is a standard procedure performed during a typical blood test. In order to formulate a unified standard of establishing reference ESR values, this paper presents a novel prediction model in which local normal ESR values and corresponding geographical factors are used to predict reference ESR values using multi-layer feed-forward artificial neural networks (ANN). Methods and findings Local normal ESR values were obtained from hospital data, while geographical factors that include altitude, sunshine hours, relative humidity, temperature and precipitation were obtained from the National Geographical Data Information Centre in China. The results show that predicted values are statistically in agreement with measured values. Model results exhibit significant agreement between training data and test data. Consequently, the model is used to predict the unseen local reference ESR values. Conclusions Reference ESR values can be established with geographical factors by using artificial intelligence techniques. ANN is an effective method for simulating and predicting reference ESR values because of its ability to model nonlinear and complex relationships. PMID:23497145
Yang, Qingsheng; Mwenda, Kevin M; Ge, Miao
2013-03-12
The measurement of the Erythrocyte Sedimentation Rate (ESR) value is a standard procedure performed during a typical blood test. In order to formulate a unified standard of establishing reference ESR values, this paper presents a novel prediction model in which local normal ESR values and corresponding geographical factors are used to predict reference ESR values using multi-layer feed-forward artificial neural networks (ANN). Local normal ESR values were obtained from hospital data, while geographical factors that include altitude, sunshine hours, relative humidity, temperature and precipitation were obtained from the National Geographical Data Information Centre in China.The results show that predicted values are statistically in agreement with measured values. Model results exhibit significant agreement between training data and test data. Consequently, the model is used to predict the unseen local reference ESR values. Reference ESR values can be established with geographical factors by using artificial intelligence techniques. ANN is an effective method for simulating and predicting reference ESR values because of its ability to model nonlinear and complex relationships.
Cramer, Stephen Paul; Pham, Cindy C; Mulder, David W; Pelmenschikov, Vladimir; King, Paul W; Ratzloff, Michael W; Wang, Hongxin; Mishra, Nakul; Alp, Ercan; Zhao, Jiyong; Hu, Michael Y; Tamasaku, Kenji; Yoda, Yoshitaka
2018-06-19
A combination of NRVS and FT-IR spectroscopies and DFT calculations was used to observe and characterize Fe-H/D bending modes in CrHydA1 [FeFe]-hydrogenase Cys-to-Ser variant C169S. Mutagenesis of cysteine to serine at position 169 changes the functional group adjacent to the H-cluster from a -SH to -OH, thus altering the proton transfer pathway. C169S has a significant reduction in catalytic activity compared to the native CrHydA1, presumably due to less efficient transfer of protons to the H-cluster. This mutation allowed effective capture of a hydride/deuteride intermediate and facilitated direct detection of the Fe-H/D normal modes. We find a significant shift to higher frequency in a Fe-H bending mode of the C169S variant, as compared to previous findings with reconstituted native and oxadithiolate (ODT) substituted CrHydA1. Rationalized by DFT calculations, we propose that this shift is caused by a stronger interaction between the -OH of C169S with the bridgehead -NH- of the active site, as compared to the -SH of C169 in the native enzyme. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Revised reference values for selenium intake.
Kipp, A P; Strohm, D; Brigelius-Flohé, R; Schomburg, L; Bechthold, A; Leschik-Bonnet, E; Heseker, H
2015-10-01
The German, Austrian and Swiss nutrition societies are the joint editors of the 'reference values for nutrient intake'. They have revised the reference values for the intake of selenium and published them in February 2015. The saturation of selenoprotein P (SePP) in plasma is used as a criterion for the derivation of reference values for selenium intake in adults. For persons from selenium-deficient regions (China) SePP saturation was achieved with a daily intake of 49μg of selenium. When using the reference body weights the D-A-CH reference values are based upon, the resulting estimated value for selenium intake is 70μg/day for men and 60μg/day for women. The estimated value for selenium intake for children and adolescents is extrapolated using the estimated value for adults in relation to body weight. For infants aged 0 to under 4 months the estimated value of 10μg/day was derived from the basis of selenium intake via breast milk. For infants aged 4 to under 12 months this estimated value was used and taking into account the differences regarding body weight an estimated value of 15μg/day was derived. For lactating women compared to non-lactating women a higher reference value of 75μg/day is indicated due to the release of selenium with breast milk. The additional selenium requirement for pregnant women is negligible, so that no increased reference value is indicated. Copyright © 2015 The Authors. Published by Elsevier GmbH.. All rights reserved.
Hematological reference values of healthy Malaysian population.
Roshan, T M; Rosline, H; Ahmed, S A; Rapiaah, M; Wan Zaidah, A; Khattak, M N
2009-10-01
Health and disease can only be distinguished by accurate and reliable reference values of a particular laboratory test. It is now a proven fact that there is considerable variation in hematology reference intervals depending on the demographic and preanalytical variables. There are evidences that values provided by manufacturers do not have appropriate application for all populations. Moreover, reference ranges provided by different laboratory manuals and books also do not solve this problem. We are presenting here normal reference ranges of Malaysian population. These values were determined by using Sysmex XE-2100 and ACL 9000 hematology and coagulation analyzers. Results from this study showed that there were considerable differences in the reference values from manufacturers, western population or laboratory manuals compared with those from the local population.
Reference values for pulmonary diffusing capacity for adult native Finns.
Kainu, Annette; Toikka, Jyri; Vanninen, Esko; Timonen, Kirsi L
2017-04-01
Measurement standards for pulmonary diffusing capacity were updated in 2005 by the ATS/ERS Task Force. However, in Finland reference values published in 1982 by Viljanen et al. have been used to date. The main aim of this study was to produce updated reference models for single-breath diffusing capacity for carbon monoxide for Finnish adults. Single-breath diffusing capacity for carbon monoxide was measured in 631 healthy non-smoking volunteers (41.5% male). Reference values for diffusing capacity (DLCO), alveolar volume (VA), diffusing capacity per unit of lung volume (DLCO/VA), and lung volumes were calculated using a linear regression model. Previously used Finnish reference values were found to produce too low predicted values, with mean predicted DLCO 111.0 and 104.4%, and DLCO/VA of 103.5 and 102.7% in males and females, respectively. With the European Coalition for Steel and Coal (ECSC) reference values there was a significant sex difference in DLCO/VA with mean predicted 105.4% in males and 92.8% in females (p < .001). New reference values for DLCO, DLCO/VA, VA, vital capacity (VC), inspiratory vital capacity (IVC), and inspiratory capacity (IC) are suggested for clinical use to replace technically outdated reference values for clinical applications.
2002-01-01
This report presents detailed information on age- and gender-related differences in the anatomical and physiological characteristics of reference individuals. These reference values provide needed input to prospective dosimetry calculations for radiation protection purposes for both workers and members of the general public. The purpose of this report is to consolidate and unify in one publication, important new information on reference anatomical and physiological values that has become available since Publication 23 was published by the ICRP in 1975. There are two aspects of this work. The first is to revise and extend the information in Publication 23 as appropriate. The second is to provide additional information on individual variation among grossly normal individuals resulting from differences in age, gender, race, or other factors. This publication collects, unifies, and expands the updated ICRP reference values for the purpose of providing a comprehensive and consistent set of age- and gender-specific reference values for anatomical and physiological features of the human body pertinent to radiation dosimetry. The reference values given in this report are based on: (a) anatomical and physiological information not published before by the ICRP; (b) recent ICRP publications containing reference value information; and (c) information in Publication 23 that is still considered valid and appropriate for radiation protection purposes. Moving from the past emphasis on 'Reference Man', the new report presents a series of reference values for both male and female subjects of six different ages: newborn, 1 year, 5 years, 10 years, 15 years, and adult. In selecting reference values, the Commission has used data on Western Europeans and North Americans because these populations have been well studied with respect to antomy, body composition, and physiology. When appropriate, comparisons are made between the chosen reference values and data from several Asian populations. The first section of the report provides summary tables of all the anatomical and physiological parameters given as reference values in this publication. These results give a comprehensive view of reference values for an individual as influenced by age and gender. The second section describes characteristics of dosimetric importance for the embryo and fetus. Information is provided on the development of the total body and the timing of appearance and development of the various organ systems. Reference values are provided on the mass of the total body and selected organs and tissues, as well as a number of physiological parameters. The third section deals with reference values of important anatomical and physiological characteristics of reference individuals from birth to adulthood. This section begins with details on the growth and composition of the total body in males and females. It then describes and quantifies anatomical and physiological characteristics of various organ systems and changes in these characteristics during growth, maturity, and pregnancy. Reference values are specified for characteristics of dosimetric importance. The final section gives a brief summary of the elemental composition of individuals. Focusing on the elements of dosimetric importance, information is presented on the body content of 13 elements: calcium, carbon, chloride, hydrogen, iodine, iron, magnesium, nitrogen, oxygen, potassium, sodium, sulphur, and phosphorus.
Statistical considerations for harmonization of the global multicenter study on reference values.
Ichihara, Kiyoshi
2014-05-15
The global multicenter study on reference values coordinated by the Committee on Reference Intervals and Decision Limits (C-RIDL) of the IFCC was launched in December 2011, targeting 45 commonly tested analytes with the following objectives: 1) to derive reference intervals (RIs) country by country using a common protocol, and 2) to explore regionality/ethnicity of reference values by aligning test results among the countries. To achieve these objectives, it is crucial to harmonize 1) the protocol for recruitment and sampling, 2) statistical procedures for deriving the RI, and 3) test results through measurement of a panel of sera in common. For harmonized recruitment, very lenient inclusion/exclusion criteria were adopted in view of differences in interpretation of what constitutes healthiness by different cultures and investigators. This policy may require secondary exclusion of individuals according to the standard of each country at the time of deriving RIs. An iterative optimization procedure, called the latent abnormal values exclusion (LAVE) method, can be applied to automate the process of refining the choice of reference individuals. For global comparison of reference values, test results must be harmonized, based on the among-country, pair-wise linear relationships of test values for the panel. Traceability of reference values can be ensured based on values assigned indirectly to the panel through collaborative measurement of certified reference materials. The validity of the adopted strategies is discussed in this article, based on interim results obtained to date from five countries. Special considerations are made for dissociation of RIs by parametric and nonparametric methods and between-country difference in the effect of body mass index on reference values. Copyright © 2014 Elsevier B.V. All rights reserved.
Reliability of reference distances used in photogrammetry.
Aksu, Muge; Kaya, Demet; Kocadereli, Ilken
2010-07-01
To determine the reliability of the reference distances used for photogrammetric assessment. The sample consisted of 100 subjects with mean ages of 22.97 +/- 2.98 years. Five lateral and four frontal parameters were measured directly on the subjects' faces. For photogrammetric assessment, two reference distances for the profile view and three reference distances for the frontal view were established. Standardized photographs were taken and all the parameters that had been measured directly on the face were measured on the photographs. The reliability of the reference distances was checked by comparing direct and indirect values of the parameters obtained from the subjects' faces and photographs. Repeated measure analysis of variance (ANOVA) and Bland-Altman analyses were used for statistical assessment. For profile measurements, the indirect values measured were statistically different from the direct values except for Sn-Sto in male subjects and Prn-Sn and Sn-Sto in female subjects. The indirect values of Prn-Sn and Sn-Sto were reliable in both sexes. The poorest results were obtained in the indirect values of the N-Sn parameter for female subjects and the Sn-Me parameter for male subjects according to the Sa-Sba reference distance. For frontal measurements, the indirect values were statistically different from the direct values in both sexes except for one in male subjects. The indirect values measured were not statistically different from the direct values for Go-Go. The indirect values of Ch-Ch were reliable in male subjects. The poorest results were obtained according to the P-P reference distance. For profile assessment, the T-Ex reference distance was reliable for Prn-Sn and Sn-Sto in both sexes. For frontal assessment, Ex-Ex and En-En reference distances were reliable for Ch-Ch in male subjects.
The Study and Measurement of Values and Attitudes.
ERIC Educational Resources Information Center
Kerlinger, Fred N.
The author defines values, attitudes, and beliefs according to their relation to referents. A referent is a construct standing for a set or category of social objects, ideas, or behaviors that is the focus of an attitude. Attitudes and values are belief systems. Beliefs are enduring cognitions about referents; beliefs reflect the value and…
USDA-ARS?s Scientific Manuscript database
Nutrient reference values have significant public health and policy implications. Given the importance of defining reliable nutrient reference values, there is a need for an explicit, objective, and transparent process to set these values. The Tufts Medical Center Evidence-based Practice Center asse...
Bedewi, Mohamed Abdelmohsen; Abodonya, Ahmed; Kotb, Mamdouh; Kamal, Sanaa; Mahmoud, Gehan; Aldossari, Khaled; Alqabbani, Abdullah; Swify, Sherine
2018-03-01
The objective of this study is to estimate the reference values for the lower limb peripheral nerves in adults.The demographics and physical characteristics of 69 adult healthy volunteers were evaluated and recorded. The estimated reference values and their correlations with the age, weight, height, body mass index (BMI) were evaluated.The cross sectional area reference values were obtained at 5 predetermined sites for 3 important lower limb peripheral nerves. Our CSA values correlated significantly with age, weight, and BMI. The normal reference values for each nerve were as follows: Tibial nerve at the popliteal fossa 19 mm ± 6.9, tibial nerve at the level of the medial malleolus 12.7 mm ± 4.5, common peroneal nerve at the popliteal fossa 9.5 mm ± 4, common peroneal nerve fibular head 8.9 mm ± 3.2, sural nerve 3.5 mm ± 1.4.The reference values for the lower limb peripheral nerves were identified. These values could be used for future management of peripheral nerve disorders.
Serum proteins by capillary zone electrophoresis: approaches to the definition of reference values.
Petrini, C; Alessio, M G; Scapellato, L; Brambilla, S; Franzini, C
1999-10-01
The Paragon CZE 2000 (Beckman Analytical, Milan, Italy) is an automatic dedicated capillary zone electrophoresis (CZE) system, producing a five-zone serum protein pattern with quantitative estimation of the zones. With the view of substituting this instrument for two previously used serum protein electrophoresis techniques, we planned to produce reference values for the "new" systems leading to compatible interpretation of the results. High resolution cellulose acetate electrophoresis with visual inspection and descriptive reporting (HR-CAE) and five-zone cellulose acetate electrophoresis with densitometry (CAE-D) were the previously used techniques. Serum samples (n = 167) giving "normal pattern" with HR-CAE were assayed with the CZE system, and the results were statistically assessed to yield 0.95 reference intervals. One thousand normal and pathological serum samples were then assayed with the CAE-D and the CZE techniques, and the regression equations of the CAE-D values over the CZE values for the five zones were used to transform the CAE-D reference limits into the CZE reference limits. The two sets of reference values thereby produced were in good agreement with each other and also with reference values previously reported for the CZE system. Thus, reference values for the CZE techniques permit interpretation of results coherent with the previously used techniques and reporting modes.
Bel Hadj Hmida, Y; Tahri, N; Sellami, A; Yangui, N; Jlidi, R; Beyrouti, M I; Krichen, M S; Masmoudi, H
2001-01-01
In order to determine the sensitivity of CEA in the diagnosis of colo-rectal carcinoma, we studied a series of 48 patients with colo-rectal carcinoma (1992-1996). The sensitivity was at 52% with a reference value of 5 ng/ml and 68.7% for a reference value of 2.5 ng/ml. With a reference value of 5 ng/ml, the sensitivity of CEA was at 37% only for patients with colo-rectal carcinoma at Dukes B stage, 66.6% for patients at stage C and 75% for patients at stage D. The dosage of CEA was carried out with a sandwich immunoenzymatic technique in tube. There is no statistic significant correlation between the pre-operative rate of CEA and the localisation of the tumor and its histologic type; in contrast, it was significantly correlated with the ganglionnary metastasis. A significant relationship between the pre-operative rate of CEA and the Dukes stage was found for a reference value of 10 ng/ml but not for a reference value of 5 ng/ml. We calculated the specificity of the CEA for the cancers of colon and rectum which was at 76.98% with a reference value of 5 ng/ml and 86% with a reference value of 10 ng/ml.
Geffré, Anne; Concordet, Didier; Braun, Jean-Pierre; Trumel, Catherine
2011-03-01
International recommendations for determination of reference intervals have been recently updated, especially for small reference sample groups, and use of the robust method and Box-Cox transformation is now recommended. Unfortunately, these methods are not included in most software programs used for data analysis by clinical laboratories. We have created a set of macroinstructions, named Reference Value Advisor, for use in Microsoft Excel to calculate reference limits applying different methods. For any series of data, Reference Value Advisor calculates reference limits (with 90% confidence intervals [CI]) using a nonparametric method when n≥40 and by parametric and robust methods from native and Box-Cox transformed values; tests normality of distributions using the Anderson-Darling test and outliers using Tukey and Dixon-Reed tests; displays the distribution of values in dot plots and histograms and constructs Q-Q plots for visual inspection of normality; and provides minimal guidelines in the form of comments based on international recommendations. The critical steps in determination of reference intervals are correct selection of as many reference individuals as possible and analysis of specimens in controlled preanalytical and analytical conditions. Computing tools cannot compensate for flaws in selection and size of the reference sample group and handling and analysis of samples. However, if those steps are performed properly, Reference Value Advisor, available as freeware at http://www.biostat.envt.fr/spip/spip.php?article63, permits rapid assessment and comparison of results calculated using different methods, including currently unavailable methods. This allows for selection of the most appropriate method, especially as the program provides the CI of limits. It should be useful in veterinary clinical pathology when only small reference sample groups are available. ©2011 American Society for Veterinary Clinical Pathology.
Heinrich, Andreas; Teichgräber, Ulf K; Güttler, Felix V
2015-12-01
The standard ASTM F2119 describes a test method for measuring the size of a susceptibility artifact based on the example of a passive implant. A pixel in an image is considered to be a part of an image artifact if the intensity is changed by at least 30% in the presence of a test object, compared to a reference image in which the test object is absent (reference value). The aim of this paper is to simplify and accelerate the test method using a histogram-based reference value. Four test objects were scanned parallel and perpendicular to the main magnetic field, and the largest susceptibility artifacts were measured using two methods of reference value determination (reference image-based and histogram-based reference value). The results between both methods were compared using the Mann-Whitney U-test. The difference between both reference values was 42.35 ± 23.66. The difference of artifact size was 0.64 ± 0.69 mm. The artifact sizes of both methods did not show significant differences; the p-value of the Mann-Whitney U-test was between 0.710 and 0.521. A standard-conform method for a rapid, objective, and reproducible evaluation of susceptibility artifacts could be implemented. The result of the histogram-based method does not significantly differ from the ASTM-conform method.
Tracer Kinetic Analysis of (S)-¹⁸F-THK5117 as a PET Tracer for Assessing Tau Pathology.
Jonasson, My; Wall, Anders; Chiotis, Konstantinos; Saint-Aubert, Laure; Wilking, Helena; Sprycha, Margareta; Borg, Beatrice; Thibblin, Alf; Eriksson, Jonas; Sörensen, Jens; Antoni, Gunnar; Nordberg, Agneta; Lubberink, Mark
2016-04-01
Because a correlation between tau pathology and the clinical symptoms of Alzheimer disease (AD) has been hypothesized, there is increasing interest in developing PET tracers that bind specifically to tau protein. The aim of this study was to evaluate tracer kinetic models for quantitative analysis and generation of parametric images for the novel tau ligand (S)-(18)F-THK5117. Nine subjects (5 with AD, 4 with mild cognitive impairment) received a 90-min dynamic (S)-(18)F-THK5117 PET scan. Arterial blood was sampled for measurement of blood radioactivity and metabolite analysis. Volume-of-interest (VOI)-based analysis was performed using plasma-input models; single-tissue and 2-tissue (2TCM) compartment models and plasma-input Logan and reference tissue models; and simplified reference tissue model (SRTM), reference Logan, and SUV ratio (SUVr). Cerebellum gray matter was used as the reference region. Voxel-level analysis was performed using basis function implementations of SRTM, reference Logan, and SUVr. Regionally averaged voxel values were compared with VOI-based values from the optimal reference tissue model, and simulations were made to assess accuracy and precision. In addition to 90 min, initial 40- and 60-min data were analyzed. Plasma-input Logan distribution volume ratio (DVR)-1 values agreed well with 2TCM DVR-1 values (R(2)= 0.99, slope = 0.96). SRTM binding potential (BP(ND)) and reference Logan DVR-1 values were highly correlated with plasma-input Logan DVR-1 (R(2)= 1.00, slope ≈ 1.00) whereas SUVr(70-90)-1 values correlated less well and overestimated binding. Agreement between parametric methods and SRTM was best for reference Logan (R(2)= 0.99, slope = 1.03). SUVr(70-90)-1 values were almost 3 times higher than BP(ND) values in white matter and 1.5 times higher in gray matter. Simulations showed poorer accuracy and precision for SUVr(70-90)-1 values than for the other reference methods. SRTM BP(ND) and reference Logan DVR-1 values were not affected by a shorter scan duration of 60 min. SRTM BP(ND) and reference Logan DVR-1 values were highly correlated with plasma-input Logan DVR-1 values. VOI-based data analyses indicated robust results for scan durations of 60 min. Reference Logan generated quantitative (S)-(18)F-THK5117 DVR-1 parametric images with the greatest accuracy and precision and with a much lower white-matter signal than seen with SUVr(70-90)-1 images. © 2016 by the Society of Nuclear Medicine and Molecular Imaging, Inc.
USDA-ARS?s Scientific Manuscript database
Workshops sponsored by the Institute of Medicine (IOM) and the World Health Organization (WHO) suggested that incorporating systematic reviews into the process of updating nutrient reference values would enhance the transparency of the process. The IOM issues the Dietary Reference Intake values (DR...
Jo, Bum Seak; Myong, Jun Pyo; Rhee, Chin Kook; Yoon, Hyoung Kyu; Koo, Jung Wan; Kim, Hyoung Ryoul
2018-01-15
The present study aimed to update the prediction equations for spirometry and their lower limits of normal (LLN) by using the lambda, mu, sigma (LMS) method and to compare the outcomes with the values of previous spirometric reference equations. Spirometric data of 10,249 healthy non-smokers (8,776 females) were extracted from the fourth and fifth versions of the Korea National Health and Nutrition Examination Survey (KNHANES IV, 2007-2009; V, 2010-2012). Reference equations were derived using the LMS method which allows modeling skewness (lambda [L]), mean (mu [M]), and coefficient of variation (sigma [S]). The outcome equations were compared with previous reference values. Prediction equations were presented in the following form: predicted value = e{a + b × ln(height) + c × ln(age) + M - spline}. The new predicted values for spirometry and their LLN derived using the LMS method were shown to more accurately reflect transitions in pulmonary function in young adults than previous prediction equations derived using conventional regression analysis in 2013. There were partial discrepancies between the new reference values and the reference values from the Global Lung Function Initiative in 2012. The results should be interpreted with caution for young adults and elderly males, particularly in terms of the LLN for forced expiratory volume in one second/forced vital capacity in elderly males. Serial spirometry follow-up, together with correlations with other clinical findings, should be emphasized in evaluating the pulmonary function of individuals. Future studies are needed to improve the accuracy of reference data and to develop continuous reference values for spirometry across all ages. © 2018 The Korean Academy of Medical Sciences.
Le, Margaret; Flores, David; May, Danica; Gourley, Eric; Nangia, Ajay K
2016-05-01
The evaluation and management of male hypogonadism should be based on symptoms and on serum testosterone levels. Diagnostically this relies on accurate testing and reference values. Our objective was to define the distribution of reference values and assays for free and total testosterone by clinical laboratories in the United States. Upper and lower reference values, assay methodology and source of published reference ranges were obtained from laboratories across the country. A standardized survey was reviewed with laboratory staff via telephone. Descriptive statistics were used to tabulate results. We surveyed a total of 120 laboratories in 47 states. Total testosterone was measured in house at 73% of laboratories. At the remaining laboratories studies were sent to larger centralized reference facilities. The mean ± SD lower reference value of total testosterone was 231 ± 46 ng/dl (range 160 to 300) and the mean upper limit was 850 ± 141 ng/dl (range 726 to 1,130). Only 9% of laboratories where in-house total testosterone testing was performed created a reference range unique to their region. Others validated the instrument recommended reference values in a small number of internal test samples. For free testosterone 82% of laboratories sent testing to larger centralized reference laboratories where equilibrium dialysis and/or liquid chromatography with mass spectrometry was done. The remaining laboratories used published algorithms to calculate serum free testosterone. Reference ranges for testosterone assays vary significantly among laboratories. The ranges are predominantly defined by limited population studies of men with unknown medical and reproductive histories. These poorly defined and variable reference values, especially the lower limit, affect how clinicians determine treatment. Copyright © 2016 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chakraborty, Saumen; Reed, Julian; Sage, Timothy
This Forum Article focuses on recent advances in structural and spectroscopic studies of biosynthetic models of nitric oxide reductases (NORs). NORs are complex metalloenzymes found in the denitrification pathway of Earth's nitrogen cycle where they catalyze the proton-dependent twoelectron reduction of nitric oxide (NO) to nitrous oxide (N 2O). While much progress has been made in biochemical and biophysical studies of native NORs and their variants, a. clear mechanistic understanding of this important metalloenzyme related to its function is still elusive. We report herein UV vis and nuclear resonance vibrational spectroscopy (NRVS) studies of mononitrosylated intermediates of the NOR reactionmore » of a biosynthetic model. The ability to selectively substitute metals at either heme or nonheme metal sites allows the introduction of independent 57Fe probe atoms at either site, as well as allowing the preparation of analogues of stable reaction intermediates by replacing either metal with a redox inactive metal. Together with previous structural and spectroscopic results, we summarize insights gained from studying these biosynthetic models toward understanding structural features responsible for the NOR activity and its mechanism. As a result, the outlook on NOR modeling is also discussed, with an emphasis on the design of models capable of catalytic turnovers designed based on close mimics of the secondary coordination sphere of native NORs.« less
Reference values for anxiety questionnaires: the Leiden Routine Outcome Monitoring Study.
Schulte-van Maaren, Yvonne W M; Giltay, Erik J; van Hemert, Albert M; Zitman, Frans G; de Waal, Margot W M; Carlier, Ingrid V E
2013-09-25
The monitoring of patients with an anxiety disorder can benefit from Routine Outcome Monitoring (ROM). As anxiety disorders differ in phenomenology, several anxiety questionnaires are included in ROM: Brief Scale for Anxiety (BSA), PADUA Inventory Revised (PI-R), Panic Appraisal Inventory (PAI), Penn State Worry Questionnaire (PSWQ), Worry Domains Questionnaire (WDQ), Social Interaction, Anxiety Scale (SIAS), Social Phobia Scale (SPS), and the Impact of Event Scale-Revised (IES-R). We aimed to generate reference values for both 'healthy' and 'clinically anxious' populations for these anxiety questionnaires. We included 1295 subjects from the general population (ROM reference-group) and 5066 psychiatric outpatients diagnosed with a specific anxiety disorder (ROM patient-group). The MINI was used as diagnostic device in both the ROM reference group and the ROM patient group. To define limits for one-sided reference intervals (95th percentile; P95) the outermost 5% of observations were used. Receiver Operating Characteristics (ROC) analyses were used to yield alternative cut-off values for the anxiety questionnaires. For the ROM reference-group the mean age was 40.3 years (SD=12.6), and for the ROM patient-group it was 36.5 years (SD=11.9). Females constituted 62.8% of the reference-group and 64.4% of the patient-group. P95 ROM reference group cut-off values for reference versus clinically anxious populations were 11 for the BSA, 43 for the PI-R, 37 for the PAI Anticipated Panic, 47 for the PAI Perceived Consequences, 65 for the PAI Perceived Self-efficacy, 66 for the PSWQ, 74 for the WDQ, 32 for the SIAS, 19 for the SPS, and 36 for IES-R. ROC analyses yielded slightly lower reference values. The discriminative power of all eight anxiety questionnaires was very high. Substantial non-response and limited generalizability. For eight anxiety questionnaires a comprehensive set of reference values was provided. Reference values were generally higher in women than in men, implying the use of gender-specific cut-off values. Each instrument can be offered to every patient with MAS disorders to make responsible decisions about continuing, changing or terminating therapy. © 2013 Elsevier B.V. All rights reserved.
Reference values of inspiratory spirometry for Finnish adults.
Kainu, Annette; Timonen, Kirsi L; Vanninen, Esko; Sovijärvi, Anssi R
2018-03-07
Inspiratory spirometry is used in evaluation of upper airway disorders e.g. fixed or variable obstruction. There are, however, very few published data on normal values for inspiratory spirometry. The main aim of this study was to produce reference values for inspiratory spirometry for healthy Finnish adults. Inspiratory spirometry was preplanned to a sample of the Finnish spirometry reference values sample. Data was successfully retrieved from 368 healthy nonsmoking adults (132 males) between 19 and 83 years of age. Reference equations were produced for forced inspiratory vital capacity (FIVC), forced inspiratory volume in one second (FIV1), FIV1/FIVC, peak inspiratory flow (PIF) and the ratios of FIV1/forced expiratory volume in one second and PIF/peak expiratory flow. The present values were compared to PIF values from previously used Finnish study of Viljanen et al. (1982) reference values and Norwegian values for FIV1, FIVC and FIV1/FIVC presented by Gulsvik et al. (2001). The predicted values from the Gulsvik et al. (2001), provided a good fit for FIVC, but smaller values for FIV1 with mean 108.3 and 109.1% of predicted values for males and females, respectively. PIF values were 87.4 and 91.2% of Viljanen et al. (1982) predicted values in males and females, respectively. Differences in measurement methods and selection of results may contribute to the observed differences. Inspiratory spirometry is technically more demanding and needs repeatability criteria to improve validity. New reference values are suggested to clinical use in Finland when assessing inspiratory spirometry. Utility of inspiratory to expiratory values indices in assessment of airway collapse need further study.
Kainu, Annette; Lindqvist, Ari; Sovijärvi, Anssi R. A.
2016-01-01
Background New Finnish (Kainu2015) and international Global Lung Function Initiative (GLI2012) reference values for spirometry were recently published. The aim of this study is to compare the interpretative consequences of adopting these new reference values with older, currently used Finnish reference values (Viljanen1982) in the general population of native Finns. Methods Two Finnish general population samples including 1,328 adults (45% males) aged 21–74 years were evaluated. Airway obstruction was defined as a reduced ratio of forced expiratory volume in one second (FEV1)/forced vital capacity (FVC), possible restrictive pattern as reduced FVC, and decreased ventilatory capacity as reduced FEV1 below their respective 2.5th percentiles. The severity gradings of reduced lung function were also compared. Results Using the Kainu2015 reference values, the prevalence of airway obstruction in the population was 5.6%; using GLI2012 it was 4.0% and with Viljanen1982 it was 13.0%. Possible restrictive pattern was found in 4.2% using the Kainu2015 values, in 2.0% with GLI2012, and 7.9% with the Viljanen1982 values. The prevalence of decreased ventilatory capacity was 6.8, 4.0, and 13.3% with the Kainu2015, GLI2012 and Viljanen1982 values, respectively. Conclusions The application of the GLI2012 reference values underestimates the prevalence of abnormal spirometric findings in native Finns. The adoption of the Kainu2015 reference values reduces the prevalences of airways obstruction, decreased ventilatory capacity, and restrictive impairment by approximately 50%. Changing from the 2.5th percentile, the previously used lower limit of normal, to the 5th percentile recommended by the American Thoracic Society/European Respiratory Society will not increase the prevalence of abnormal findings in the implementation of spirometry reference values. PMID:27608270
Reference values of elements in human hair: a systematic review.
Mikulewicz, Marcin; Chojnacka, Katarzyna; Gedrange, Thomas; Górecki, Henryk
2013-11-01
The lack of systematic review on reference values of elements in human hair with the consideration of methodological approach. The absence of worldwide accepted and implemented universal reference ranges causes that hair mineral analysis has not become yet a reliable and useful method of assessment of nutritional status and exposure of individuals. Systematic review of reference values of elements in human hair. PubMed, ISI Web of Knowledge, Scopus. Humans, hair mineral analysis, elements or minerals, reference values, original studies. The number of studies screened and assessed for eligibility was 52. Eventually, included in the review were 5 papers. The studies report reference ranges for the content of elements in hair: macroelements, microelements, toxic elements and other elements. Reference ranges were elaborated for different populations in the years 2000-2012. The analytical methodology differed, in particular sample preparation, digestion and analysis (ICP-AES, ICP-MS). Consequently, the levels of hair minerals reported as reference values varied. It is necessary to elaborate the standard procedures and furtherly validate hair mineral analysis and deliver detailed methodology. Only then it would be possible to provide meaningful reference ranges and take advantage of the potential that lies in Hair Mineral Analysis as a medical diagnostic technique. Copyright © 2013 Elsevier B.V. All rights reserved.
The theory of reference values: an unfinished symphony.
Siest, Gerard; Henny, Joseph; Gräsbeck, Ralph; Wilding, Peter; Petitclerc, Claude; Queraltó, Josep M; Hyltoft Petersen, Peter
2013-01-01
The history of the theory of reference values can be written as an unfinished symphony. The first movement, allegro con fuoco, played from 1960 to 1980: a mix of themes devoted to the study of biological variability (intra-, inter-individual, short- and long-term), preanalytical conditions, standardization of analytical methods, quality control, statistical tools for deriving reference limits, all of them complex variations developed on a central melody: the new concept of reference values that would replace the notion of normality whose definition was unclear. Additional contributions (multivariate reference values, use of reference limits from broad sets of patient data, drug interferences) conclude the movement on the variability of laboratory tests. The second movement, adagio, from 1980 to 2000, slowly develops and implements initial works. International and national recommendations were published by the IFCC-LM (International Federation of Clinical Chemistry and Laboratory Medicine) and scientific societies [French (SFBC), Spanish (SEQC), Scandinavian societies…]. Reference values are now topics of many textbooks and of several congresses, workshops, and round tables that are organized all over the world. Nowadays, reference values are part of current practice in all clinical laboratories, but not without difficulties, particularly for some laboratories to produce their own reference values and the unsuitability of the concept with respect to new technologies such as HPLC, GCMS, and PCR assays. Clinicians through consensus groups and practice guidelines have introduced their own tools, the decision limits, likelihood ratios and Reference Change Value (RCV), creating confusion among laboratorians and clinicians in substituting reference values and decision limits in laboratory reports. The rapid development of personalized medicine will eventually call for the use of individual reference values. The beginning of the second millennium is played allegro ma non-troppo from 2000 to 2012: the theory of reference values is back into fashion. The need to revise the concept is emerging. The manufacturers make a friendly pressure to facilitate the integration of Reference Intervals (RIs) in their technical documentation. Laboratorians are anxiously awaiting the solutions for what to do. The IFCC-LM creates Reference Intervals and Decision Limits Committee (C-RIDL) in 2005. Simultaneously, a joint working group IFCC-CLSI is created on the same topic. In 2008 the initial recommendations of IFCC-LM are revised and new guidelines are published by the Clinical and Laboratory Standards Institute (CLSI C28-A3). Fundamentals of the theory of reference values are not changed, but new avenues are explored: RIs transference, multicenter reference intervals, and a robust method for deriving RIs from small number of subjects. Concomitantly, other statistical methods are published such as bootstraps calculation and partitioning procedures. An alternative to recruiting healthy subjects proposes the use of biobanks conditional to the availability of controlled preanalytical conditions and of bioclinical data. The scope is also widening to include veterinary biology! During the early 2000s, several groups proposed the concept of 'Universal RIs' or 'Global RIs'. Still controversial, their applications await further investigations. The fourth movement, finale: beyond the methodological issues (statistical and analytical essentially), important questions remain unanswered. Do RIs intervene appropriately in medical decision-making? Are RIs really useful to the clinicians? Are evidence-based decision limits more appropriate? It should be appreciated that many laboratory tests represent a continuum that weakens the relevance of RIs. In addition, the boundaries between healthy and pathological states are shady areas influenced by many biological factors. In such a case the use of a single threshold is questionable. Wherever it will apply, individual reference values and reference change values have their place. A variation on an old theme! It is strange that in the period of personalized medicine (that is more stratified medicine), the concept of reference values which is based on stratification of homogeneous subgroups of healthy people could not be discussed and developed in conjunction with the stratification of sick patients. That is our message for the celebration of the 50th anniversary of Clinical Chemistry and Laboratory Medicine. Prospects are broad, enthusiasm is not lacking: much remains to be done, good luck for the new generations!
Nonparametric spirometry reference values for Hispanic Americans.
Glenn, Nancy L; Brown, Vanessa M
2011-02-01
Recent literature sites ethnic origin as a major factor in developing pulmonary function reference values. Extensive studies established reference values for European and African Americans, but not for Hispanic Americans. The Third National Health and Nutrition Examination Survey defines Hispanic as individuals of Spanish speaking cultures. While no group was excluded from the target population, sample size requirements only allowed inclusion of individuals who identified themselves as Mexican Americans. This research constructs nonparametric reference value confidence intervals for Hispanic American pulmonary function. The method is applicable to all ethnicities. We use empirical likelihood confidence intervals to establish normal ranges for reference values. Its major advantage: it is model free, but shares asymptotic properties of model based methods. Statistical comparisons indicate that empirical likelihood interval lengths are comparable to normal theory intervals. Power and efficiency studies agree with previously published theoretical results.
Ning, Lei; Song, Li-Jiang; Fan, Shun-Wu; Zhao, Xing; Chen, Yi-Lei; Li, Zhao-Zhi; Hu, Zi-Ang
2017-10-11
This study established gender-specific reference values in mainland Chinese (MC) and is important for quantitative morphometry for diagnosis and epidemiological study of osteoporotic vertebral compressive fracture. Comparisons of reference values among different racial populations are then performed to demonstrate the MC-specific characteristic. Osteoporotic vertebral compressive fracture (OVCF) is a common complication of osteoporosis in the elder population. Clinical diagnosis and epidemiological study of OVCF often employ quantitative morphometry, which relies heavily on the comparison of patients' vertebral parameters to existing reference values derived from the normal population. Thus, reference values are crucial in clinical diagnosis. To our knowledge, this is the first study to establish reference values of the mainland Chinese (MC) for quantitative morphometry. Vertebral heights including anterior (Ha), middle (Hm), posterior (Hp) heights, and predicted posterior height (pp) from T4 to L5 were obtained; and ratios of Ha/Hp, Hm/Hp and Hp/pp. were calculated from 585 MC (both female and male) for establishing reference values and subsequent comparisons with other studies. Vertebral heights increased progressively from T4 to L3 but then decreased in L4 and L5. Both genders showed similar ratios of vertebral dimensions, but male vertebrae were statistically larger than those of female (P < 0.01). Vertebral size of MC population was smaller than that of US and UK population, but was surprisingly larger than that of Hong Kong Chinese, although these two are commonly considered as one race. Data from different racial populations showed similar dimensional ratios in all vertebrae. We established gender-specific reference values for MC. Our results also indicated the necessity of establishing reference values that are not only race- and gender-specific, but also population- or region-specific for accurate quantitative morphometric assessment of OVCF.
Qi, Haiping; Lorenz, Jennifer M.; Coplen, Tyler B.; Tarbox, Lauren V.; Mayer, Bernhard; Taylor, Steve
2014-01-01
RESULTS: The δ2H and δ18O values of this reference water are –150.2 ± 0.5 ‰ and –19.80 ± 0.02 ‰, respectively, relative to VSMOW on scales normalized such that the δ2H and δ18O values of SLAP reference water are, respectively, –428 and –55.5 ‰. Each uncertainty is an estimated expanded uncertainty (U = 2uc) about the reference value that provides an interval that has about a 95-percent probability of encompassing the true value. CONCLUSION: This isotopic reference material, designated as USGS47, is intended as one of two isotopic reference waters for daily normalization of stable hydrogen and stable oxygen isotopic analysis of water with a mass spectrometer or a laser absorption spectrometer. "
dos Santos, Sabrina Novaes; Alleoni, Luís Reynaldo Ferracciú
2013-07-01
Guideline values are used to identify polluted or contaminated areas based on background values. Brazilian law establishes three guideline values for pollutants: a quality reference value (QRV), a prevention value, and an intervention value. Reference values refer to the natural concentration of an element or a substance in soils that have not been modified by anthropogenic impacts. These values inform assessments of soil quality and are used to establish maximum permissible limits. The objective of this study was to determine the natural levels and reference values for Cd, Co, Cr, Cu, Ni, Pb, and Zn in samples from the surface layer (0-20 cm) of 19 representative soils of the states of Mato Grosso and Rondônia, on Brazil's agricultural frontier. Pseudo-total metal concentrations were obtained following microwave-assisted digestion using the aqua regia and EPA3051 methods. QRVs were calculated for each element as the 75th and 90th percentiles of the frequency distribution of the data. Natural levels of heavy metals in the soil samples followed the order: Cr > Zn > Cu > Co > Pb > Ni > and Cd (aqua regia) and Cr > Co > Cu > Pb > Zn > Ni > Cd (EPA3051). These values are generally lower than those reported in the Brazilian and international literature, which highlights the importance of establishing reference values for each state or for each soil type, taking into account the geomorphological, pedological, and geological diversity of the region under study.
Zacharasiewicz, Angela; Renner, Sabine; Haderer, Flora; Weber, Michael; Dehlink, Eleonore; Szepfalusi, Zsolt; Frischer, Thomas
2017-08-01
Interpretation of lung function values in children with cystic fibrosis (CF) depends on the applied reference values. We hypothesize that differences between the new global lung function initiative (GLI) values and the formerly used Zapletal et al. values produce significantly different clinical results. We analyzed 3719 lung function measurements of 108 children and adolescents (n = 54 male; aged 6-18 years) with CF treated between September 1991 and July 2009. Data were analyzed in milliliters (ml) and % predicted (pred.) and interpreted using Zapletal and GLI reference values. Applying GLI compared to Zapletal resulted in significantly lower mean forced expiratory volume in 1s (FEV1)% pred. Zapletal 86.6% (SD 20.6), GLI 79.9% (SD 20.3) and 32% (n = 497/1543) were misclassified as normal when using Zapletal. Despite showing no overall differences in FEV1 and forced vital capacity (FVC) between concomitant Pseudomonas detection (PA+) in n = 938 and Pseudomonas negative (PA-) (n = 2781) using either reference PA+ resulted in lower FEV1 and FVC values with increasing age; however, measurement of small airway obstruction with forced expiratory flow at 75% of FVC (FEF75) values - available for Zapletal -showed significant differences. Reassurance regarding lung function when using old reference values may occur with potential clinical significance. Discrepancies in lung function interpretation underline the importance of using uniform and best available reference values.
Li, Meng-Jiao; Ge, Miao; Wang, Cong-Xia; Cen, Min-Yi; Jiang, Ji-Lin; He, Jin-Wei; Lin, Qian-Yi; Liu, Xin
2016-08-20
To analyze the relationship between the reference values of fibrinogen (FIB) in healthy Chinese adults and geographical factors to provide scientific evidences for establishing the uniform standard. The reference values of FIB of 10701 Chinese healthy adults from 103 cities were collected to investigate their relationship with 18 geographical factors including spatial index, terrain index, climate index, and soil index. Geographical factors that significantly correlated with the reference values were selected for constructing the BP neural network model. The spatial distribution map of the reference value of FIB of healthy Chinese adults was fitted by disjunctive kriging interpolation. We used the 5-layer neural network and selected 2000 times of training covering 11 hidden layers to build the simulation rule for simulating the relationship between FIB and geographical environmental factors using the MATLAB software. s The reference value of FIB in healthy Chinese adults was significantly correlated with the latitude, sunshine duration, annual average temperature, annual average relative humidity, annual precipitation, annual range of air temperature, average annual soil gravel content, and soil cation exchange capacity (silt). The artificial neural networks were created to analyze the simulation of the selected indicators of geographical factors. The spatial distribution map of the reference values of FIB in healthy Chinese adults showed a distribution pattern that FIB levels were higher in the South and lower in the North, and higher in the East and lower in the West. When the geographical factors of a certain area are known, the reference values of FIB in healthy Chinese adults can be obtained by establishing the neural network mode or plotting the spatial distribution map.
Hematologic and serum chemistry reference intervals for free-ranging lions (Panthera leo).
Maas, Miriam; Keet, Dewald F; Nielen, Mirjam
2013-08-01
Hematologic and serum chemistry values are used by veterinarians and wildlife researchers to assess health status and to identify abnormally high or low levels of a particular blood parameter in a target species. For free-ranging lions (Panthera leo) information about these values is scarce. In this study 7 hematologic and 11 serum biochemistry values were evaluated from 485 lions from the Kruger National Park, South Africa. Significant differences between sexes and sub-adult (≤ 36 months) and adult (>36 months) lions were found for most of the blood parameters and separate reference intervals were made for those values. The obtained reference intervals include the means of the various blood parameter values measured in captive lions, except for alkaline phosphatase in the subadult group. These reference intervals can be utilized for free-ranging lions, and may likely also be used as reference intervals for captive lions. Copyright © 2013 Elsevier Ltd. All rights reserved.
Han, Xiao; Ge, Miao; Dong, Jie; Xue, Ranying; Wang, Zixuan; He, Jinwei
2014-09-01
The aim of this paper is to analyze the geographical distribution of reference value of aging people's left ventricular end systolic diameter (LVDs), and to provide a scientific basis for clinical examination. The study is focus on the relationship between reference value of left ventricular end systolic diameter of aging people and 14 geographical factors, selecting 2495 samples of left ventricular end systolic diameter (LVDs) of aging people in 71 units of China, in which including 1620 men and 875 women. By using the Moran's I index to make sure the relationship between the reference values and spatial geographical factors, extracting 5 geographical factors which have significant correlation with left ventricular end systolic diameter for building the support vector regression, detecting by the method of paired sample t test to make sure the consistency between predicted and measured values, finally, makes the distribution map through the disjunctive kriging interpolation method and fits the three-dimensional trend of normal reference value. It is found that the correlation between the extracted geographical factors and the reference value of left ventricular end systolic diameter is quite significant, the 5 indexes respectively are latitude, annual mean air temperature, annual mean relative humidity, annual precipitation amount, annual range of air temperature, the predicted values and the observed ones are in good conformity, there is no significant difference at 95% degree of confidence. The overall trend of predicted values increases from west to east, increases first and then decreases from north to south. If geographical values are obtained in one region, the reference value of left ventricular end systolic diameter of aging people in this region can be obtained by using the support vector regression model. It could be more scientific to formulate the different distributions on the basis of synthesizing the physiological and the geographical factors. -Use Moran's index to analyze the spatial correlation. -Choose support vector machine to build model that overcome complexity of variables. -Test normal distribution of predicted data to guarantee the interpolation results. -Through trend analysis to explain the changes of reference value clearly. Copyright © 2014 Elsevier Inc. All rights reserved.
Reference-dependent risk sensitivity as rational inference.
Denrell, Jerker C
2015-07-01
Existing explanations of reference-dependent risk sensitivity attribute it to cognitive imperfections and heuristic choice processes. This article shows that behavior consistent with an S-shaped value function could be an implication of rational inferences about the expected values of alternatives. Theoretically, I demonstrate that even a risk-neutral Bayesian decision maker, who is uncertain about the reliability of observations, should use variability in observed outcomes as a predictor of low expected value for outcomes above a reference level, and as a predictor of high expected value for outcomes below a reference level. Empirically, I show that combining past outcomes using an S-shaped value function leads to accurate predictions about future values. The theory also offers a rationale for why risk sensitivity consistent with an inverse S-shaped value function should occur in experiments on decisions from experience with binary payoff distributions. (c) 2015 APA, all rights reserved).
Understanding and Applying the Concept of Value Creation in Radiology.
Larson, David B; Durand, Daniel J; Siegal, Daniel S
2017-04-01
The concept of value in radiology has been strongly advocated in recent years as a means of advancing patient care and decreasing waste. This article explores the concept of value creation in radiology and offers a framework for how radiology practices can create value according to the needs of their referring clinicians. Value only exists in the eyes of a customer. We propose that the primary purpose of diagnostic radiology is to answer clinical questions using medical imaging to help guide management of patient care. Because they are the direct recipient of this service, we propose that referring clinicians are the direct customers of a radiology practice and patients are indirect customers. Radiology practices create value as they understand and fulfill their referring clinicians' needs. To narrow those needs to actionable categories, we propose a framework consisting of four major dimensions: (1) how quickly the clinical question needs to be answered, (2) the degree of specialization required to answer the question, (3) how often the referring clinician uses imaging, and (4) the breadth of imaging that the referring clinician uses. We further identify three major settings in which referring clinicians utilize radiological services: (1) emergent or urgent care, (2) primary care, and (3) specialty care. Practices best meet these needs as they engage with their referring clinicians, create a shared vision, work together as a cohesive team, structure the organization to meet referring clinicians' needs, build the tools, and continually improve in ways that help referring clinicians care for patients. Copyright © 2016 American College of Radiology. Published by Elsevier Inc. All rights reserved.
Reference values for 34 frequently used laboratory tests in 80-year-old men and women.
Helmersson-Karlqvist, Johanna; Ridefelt, Peter; Lind, Lars; Larsson, Anders
2016-10-01
Reference values are usually based on blood samples from healthy individuals in the age range 20-50 years. Most patients seeking health care are older than this reference population. Many reference intervals are age dependent and there is thus a need to have appropriate reference intervals also for elderly individuals. We analyzed a group of frequently used laboratory tests in an 80-year-old population (n=531, 266 females and 265 males). The 2.5th and 97.5th percentiles for these markers were calculated according to the International Federation of Clinical Chemistry guidelines on the statistical treatment of reference values. Reference values are reported for serum alanine transaminase (ALT), albumin, alkaline phosphatase, pancreatic amylase, apolipoprotein A1, apolipoprotein B, apolipoprotein B/apolipoprotein A1 ratio, aspartate aminotransferase (AST), AST/ALT ratio, bilirubin, calcium, calprotectin, cholesterol, HDL-cholesterol, creatinine kinase (CK), creatinine, creatinine estimated GFR, C-reactive protein, cystatin C, cystatin C estimated GFR, gamma-glutamyltransferase (GGT), iron, iron saturation, lactate dehydrogenase (LDH), magnesium, phosphate, transferrin, triglycerides, urate, urea, zinc, hemoglobin, platelet count and white blood cell count. The upper reference limit for creatinine and urea was significantly increased while the lower limit for iron and albumin was decreased in this elderly population in comparison with the population in the Nordic Reference Interval Project (NORIP). Reference values calculated from the whole population and a subpopulation without cardiovascular disease showed strong concordance. Several of the reference interval limits were outside the 90% confidence interval of NORIP. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Conversion of ICRP male reference phantom to polygon-surface phantom
NASA Astrophysics Data System (ADS)
Yeom, Yeon Soo; Han, Min Cheol; Kim, Chan Hyeong; Jeong, Jong Hwi
2013-10-01
The International Commission on Radiological Protection (ICRP) reference phantoms, developed based on computed tomography images of human bodies, provide much more realism of human anatomy than the previously used MIRD5 (Medical Internal Radiation Dose) mathematical phantoms. It has been, however, realized that the ICRP reference phantoms have some critical limitations showing a considerable amount of holes for the skin and wall organs mainly due to the nature of voxels of which the phantoms are made, especially due to their low voxel resolutions. To address this problem, we are planning to develop the polygon-surface version of ICRP reference phantoms by directly converting the ICRP reference phantoms (voxel phantoms) to polygon-surface phantoms. The objective of this preliminary study is to see if it is indeed possible to construct the high-quality polygon-surface phantoms based on the ICRP reference phantoms maintaining identical organ morphology and also to identify any potential issues, and technologies to address these issues, in advance. For this purpose, in the present study, the ICRP reference male phantom was roughly converted to a polygon-surface phantom. Then, the constructed phantom was implemented in Geant4, Monte Carlo particle transport code, for dose calculations, and the calculated dose values were compared with those of the original ICRP reference phantom to see how much the calculated dose values are sensitive to the accuracy of the conversion process. The results of the present study show that it is certainly possible to convert the ICRP reference phantoms to surface phantoms with enough accuracy. In spite of using relatively less resources (<2 man-months), we were able to construct the polygon-surface phantom with the organ masses perfectly matching the ICRP reference values. The analysis of the calculated dose values also implies that the dose values are indeed not very sensitive to the detailed morphology of the organ models in the phantom for highly penetrating radiations such as photons and neutrons. The results of the electron beams, on the other hand, show that the dose values of the polygon-surface phantom are higher by a factor of 2-5 times than those of the ICRP reference phantom for the skin and wall organs which have large holes due to low voxel resolution. The results demonstrate that the ICRP reference phantom could provide significantly unreasonable dose values to thin or wall organs especially for weakly penetrating radiations. Therefore, when compared to the original ICRP reference phantoms, it is believed that the polygon-surface version of ICRP reference phantoms properly developed will not only provide the same or similar dose values (say, difference <5 or 10%) for highly penetrating radiations, but also provide correct dose values for the weakly penetrating radiations such as electrons and other charged particles.
Oh, Hea Lin; Lee, Jun Ah; Kim, Dong Ho; Lim, Jung Sub
2018-03-01
Ferritin reference values vary by age, gender, and ethnicity. We aimed to determine reference values of serum ferritin (SF) and the percentage of transferrin saturation (TSAT) for Korean children and adolescents. We analyzed data from 2,487 participants (1,311 males and 1,176 females) aged 10-20 years from the Korea National Health and Nutrition Examination Survey (2010-2012). We calculated age- and gender-stratified means and percentile values for SF and TSAT. We first plotted mean SF and TSAT by gender and according to age. In males, mean SF tended to be relatively constant among participants aged 10 to 14 years, with an upward trend thereafter. Mean SF trended downward among female participants until the age of 15 years and remained constant thereafter. Thus, significant gender differences in ferritin exist from the age of 14 years. High levels of SF were associated with obesity, and lower SF levels were associated with anemia and menarche status. We established reference values of SF and TSAT according to age and gender. The reference values for SF calculated in this study can be used to test the association between SF values and other defined diseases in Korean children and adolescents.
Handwriting assessment of Franco-Quebec primary school-age students
Couture, Mélanie; Morin, Marie-France; Coallier, Mélissa; Lavigne, Audrey; Archambault, Patricia; Bolduc, Émilie; Chartier, Émilie; Liard, Karolane; Jasmin, Emmanuelle
2016-12-01
Reasons for referring school-age children to occupational therapy mainly relate to handwriting problems. However, there are no validated tools or reference values for assessing handwriting in francophone children in Canada. This study aimed to adapt and validate the writing tasks described in an English Canadian handwriting assessment protocol and to develop reference values for handwriting speed for francophone children. Three writing tasks from the Handwriting Assessment Protocol-2nd Edition (near-point and far-point copying and dictation) were adapted for Québec French children and administered to 141 Grade 1 ( n = 73) and Grade 2 ( n = 68) students. Reference values for handwriting speed were obtained for near point and far point copying tasks. This adapted protocol and these reference values for speed will improve occupational therapy handwriting assessments for the target population.
[Effect of emotional content and self reference of learning materials on recall performance].
Spies, K
1994-01-01
It is assumed that high affective value and high self-reference of learning material help to improve memory performance as these factors allow better memory consolidation (activation hypothesis) or better integration of the new material into existing knowledge structures (extent-of-processing hypothesis). To test this assumption, 60 subjects were shown 16 short advertising films characterized by low vs. high affective value and low vs. high self-reference. Both factors were varied within subjects. After the films had each been presented twice, subjects had to recall the product names and answer two questions to each film. Results showed for both dependent variables that films with high affective values were better remembered than films with low affective values. The same held true--though to a lower extent--with respect to self-reference. According to the expected linear trend, performance was best for material scoring high on affective value as well as on self-reference, while it was worst for material scoring low on both factors.
[Reference values for lead in blood in urban population in southern Brazil].
Paoliello, M M; Gutierrez, P R; Turini, C A; Matsuo, T; Mezzaroba, L; Barbosa, D S; Carvalho, S R; Alvarenga, A L; Rezende, M I; Figueiroa, G A; Leite, V G; Gutierrez, A C; Lobo, B C; Cascales, R A
2001-05-01
To describe the reference values for lead in blood in an urban population in the city of Londrina, in the state of Paraná, Brazil. The reference population was composed of 520 adult volunteers who were assessed from November 1994 to December 1996. Exclusion criteria were: occupational exposure to lead, exposure through personal habits or practices, smoking more than 10 cigarettes per day, and living near industrial plants or other places that use lead in their production processes. Also excluded were individuals with abnormal clinical or laboratory results or with chronic diseases or cardiovascular disorders. Lead blood levels were determined using air-acetylene flame atomic absorption spectrophotometry. The detectable limit was 1.23 micrograms/dL. After the analyses of lead in blood, the following values were determined: minimum value, first quartile, median, third quartile, and maximum value; geometric mean; 95% confidence interval; experimental interval; and reference value. The reference values for lead in blood ranged from 1.20 micrograms/dL to 13.72 micrograms/dL. The geometric mean was 5.5 micrograms/dL. In general, the values found in this study are lower than those that have been reported for other countries. Additional data should be gathered from Brazilian populations living in more-industrialized areas.
Yiming, Gulinuer; Zhou, Xianhui; Lv, Wenkui; Peng, Yi; Zhang, Wenhui; Cheng, Xinchun; Li, Yaodong; Xing, Qiang; Zhang, Jianghua; Zhou, Qina; Zhang, Ling; Lu, Yanmei; Wang, Hongli; Tang, Baopeng
2017-01-01
Brachial-ankle pulse wave velocity (baPWV), a direct measure of aortic stiffness, has increasingly become an important assessment for cardiovascular risk. The present study established the reference and normal values of baPWV in a Central Asia population in Xinjiang, China. We recruited participants from a central Asia population in Xinjiang, China. We performed multiple regression analysis to investigate the determinants of baPWV. The median and 10th-90th percentiles were calculated to establish the reference and normal values based on these categories. In total, 5,757 Han participants aged 15-88 years were included in the present study. Spearman correlation analysis showed that age (r = 0.587, p < 0.001) and mean blood pressure (MBP, r = 0.599, p <0.001) were the major factors influencing the values of baPWV in the reference population. Furthermore, in the multiple linear regression analysis, the standardized regression coefficients of age (0.445) and MBP (0.460) were much higher than those of body mass index, triglyceride, and glycemia (-0.054, 0.035, and 0.033, respectively). In the covariance analysis, after adjustment for age and MBP, only diabetes was the significant independent determinant of baPWV (p = 0.009). Thus, participants with diabetes were excluded from the reference value population. The reference values ranged from 14.3 to 25.2 m/s, and the normal values ranged from 13.9 to 21.2 m/s. This is the first study that has established the reference and normal values for baPWV according to age and blood pressure in a Central Asia population.
Torén, Kjell; Murgia, Nicola; Schiöler, Linus; Bake, Björn; Olin, Anna-Carin
2017-08-25
Fractional exhaled nitric oxide (FE NO ) is used to assess of airway inflammation; diagnose asthma and monitor adherence to advised therapy. Reliable and accurate reference values for FE NO are needed for both non-smoking and current smoking adults in the clinical setting. The present study was performed to establish reference adult FE NO values among never-smokers, former smokers and current smokers. FE NO was measured in 5265 subjects aged 25-75 years in a general-population study, using a chemiluminescence (Niox ™) analyser according to the guidelines of the American Thoracic Society and the European Respiratory Society. Atopy was based on the presence of immunoglobulin E (IgE) antibodies to common inhalant allergens (measured using Phadiatop® test). Spirometry without bronchodilation was performed and forced vital capacity (FVC), forced expired volume in 1 s (FEV 1 ) and the ratio of FEV 1 to FVC values were obtained. After excluding subjects with asthma, chronic bronchitis, spirometric airway obstruction and current cold, 3378 subjects remained. Equations for predictions of FE NO values were modelled using nonparametric regression models. FE NO levels were similar in never-smokers and former smokers, and these two groups were therefore merged into a group termed "non-smokers". Reference equations, including the 5th and 95th percentiles, were generated for female and male non-smokers, based on age, height and atopy. Regression models for current smokers were unstable. Hence, the proposed reference values for current smokers are based on the univariate distribution of FE NO and fixed cut-off limits. Reference values for FE NO among respiratory healthy non-smokers should be outlined stratified for gender using individual reference values. For current smokers separate cut-off limits are proposed.
Nationwide Multicenter Reference Interval Study for 28 Common Biochemical Analytes in China.
Xia, Liangyu; Chen, Ming; Liu, Min; Tao, Zhihua; Li, Shijun; Wang, Liang; Cheng, Xinqi; Qin, Xuzhen; Han, Jianhua; Li, Pengchang; Hou, Li'an; Yu, Songlin; Ichihara, Kiyoshi; Qiu, Ling
2016-03-01
A nationwide multicenter study was conducted in the China to explore sources of variation of reference values and establish reference intervals for 28 common biochemical analytes, as a part of the International Federation of Clinical Chemistry and Laboratory Medicine, Committee on Reference Intervals and Decision Limits (IFCC/C-RIDL) global study on reference values. A total of 3148 apparently healthy volunteers were recruited in 6 cities covering a wide area in China. Blood samples were tested in 2 central laboratories using Beckman Coulter AU5800 chemistry analyzers. Certified reference materials and value-assigned serum panel were used for standardization of test results. Multiple regression analysis was performed to explore sources of variation. Need for partition of reference intervals was evaluated based on 3-level nested ANOVA. After secondary exclusion using the latent abnormal values exclusion method, reference intervals were derived by a parametric method using the modified Box-Cox formula. Test results of 20 analytes were made traceable to reference measurement procedures. By the ANOVA, significant sex-related and age-related differences were observed in 12 and 12 analytes, respectively. A small regional difference was observed in the results for albumin, glucose, and sodium. Multiple regression analysis revealed BMI-related changes in results of 9 analytes for man and 6 for woman. Reference intervals of 28 analytes were computed with 17 analytes partitioned by sex and/or age. In conclusion, reference intervals of 28 common chemistry analytes applicable to Chinese Han population were established by use of the latest methodology. Reference intervals of 20 analytes traceable to reference measurement procedures can be used as common reference intervals, whereas others can be used as the assay system-specific reference intervals in China.
Nationwide Multicenter Reference Interval Study for 28 Common Biochemical Analytes in China
Xia, Liangyu; Chen, Ming; Liu, Min; Tao, Zhihua; Li, Shijun; Wang, Liang; Cheng, Xinqi; Qin, Xuzhen; Han, Jianhua; Li, Pengchang; Hou, Li’an; Yu, Songlin; Ichihara, Kiyoshi; Qiu, Ling
2016-01-01
Abstract A nationwide multicenter study was conducted in the China to explore sources of variation of reference values and establish reference intervals for 28 common biochemical analytes, as a part of the International Federation of Clinical Chemistry and Laboratory Medicine, Committee on Reference Intervals and Decision Limits (IFCC/C-RIDL) global study on reference values. A total of 3148 apparently healthy volunteers were recruited in 6 cities covering a wide area in China. Blood samples were tested in 2 central laboratories using Beckman Coulter AU5800 chemistry analyzers. Certified reference materials and value-assigned serum panel were used for standardization of test results. Multiple regression analysis was performed to explore sources of variation. Need for partition of reference intervals was evaluated based on 3-level nested ANOVA. After secondary exclusion using the latent abnormal values exclusion method, reference intervals were derived by a parametric method using the modified Box–Cox formula. Test results of 20 analytes were made traceable to reference measurement procedures. By the ANOVA, significant sex-related and age-related differences were observed in 12 and 12 analytes, respectively. A small regional difference was observed in the results for albumin, glucose, and sodium. Multiple regression analysis revealed BMI-related changes in results of 9 analytes for man and 6 for woman. Reference intervals of 28 analytes were computed with 17 analytes partitioned by sex and/or age. In conclusion, reference intervals of 28 common chemistry analytes applicable to Chinese Han population were established by use of the latest methodology. Reference intervals of 20 analytes traceable to reference measurement procedures can be used as common reference intervals, whereas others can be used as the assay system-specific reference intervals in China. PMID:26945390
Summary Diagrams for Coupled Hydrodynamic-Ecosystem Model Skill Assessment
2009-01-01
reference point have the smallest unbiased RMSD value (Fig. 3). It would appear that the cluster of model points closest to the reference point may...total RMSD values. This is particularly the case for phyto- plankton absorption (Fig. 3B) where the cluster of points closest to the reference...pattern statistics and the bias (difference of mean values) each magnitude of the total Root-Mean-Square Difference ( RMSD ). An alternative skill score and
Reference value sensitivity of measures of unfair health inequality
García-Gómez, Pilar; Schokkaert, Erik; Van Ourti, Tom
2014-01-01
Most politicians and ethical observers are not interested in pure health inequalities, as they want to distinguish between different causes of health differences. Measures of “unfair” inequality - direct unfairness and the fairness gap, but also the popular standardized concentration index - therefore neutralize the effects of what are considered to be “legitimate” causes of inequality. This neutralization is performed by putting a subset of the explanatory variables at reference values, e.g. their means. We analyze how the inequality ranking of different policies depends on the specific choice of reference values. We show with mortality data from the Netherlands that the problem is empirically relevant and we suggest a statistical method for fixing the reference values. PMID:24954998
Adeli, Khosrow; Higgins, Victoria; Nieuwesteeg, Michelle; Raizman, Joshua E; Chen, Yunqi; Wong, Suzy L; Blais, David
2015-08-01
Defining laboratory biomarker reference values in a healthy population and understanding the fluctuations in biomarker concentrations throughout life and between sexes are critical to clinical interpretation of laboratory test results in different disease states. The Canadian Health Measures Survey (CHMS) has collected blood samples and health information from the Canadian household population. In collaboration with the Canadian Laboratory Initiative on Pediatric Reference Intervals (CALIPER), the data have been analyzed to determine reference value distributions and reference intervals for several endocrine and special chemistry biomarkers in pediatric, adult, and geriatric age groups. CHMS collected data and blood samples from thousands of community participants aged 3 to 79 years. We used serum samples to measure 13 immunoassay-based special chemistry and endocrine markers. We assessed reference value distributions and, after excluding outliers, calculated age- and sex-specific reference intervals, along with corresponding 90% CIs, according to CLSI C28-A3 guidelines. We observed fluctuations in biomarker reference values across the pediatric, adult, and geriatric age range, with stratification required on the basis of age for all analytes. Additional sex partitions were required for apolipoprotein AI, homocysteine, ferritin, and high sensitivity C-reactive protein. The unique collaboration between CALIPER and CHMS has enabled, for the first time, a detailed examination of the changes in various immunochemical markers that occur in healthy individuals of different ages. The robust age- and sex-specific reference intervals established in this study provide insight into the complex biological changes that take place throughout development and aging and will contribute to improved clinical test interpretation. © 2015 American Association for Clinical Chemistry.
Iversen, B S; Sabbioni, E; Fortaner, S; Pietra, R; Nicolotti, A
2003-01-20
Statistical data treatment is a key point in the assessment of trace element reference values being the conclusive stage of a comprehensive and organized evaluation process of metal concentration in human body fluids. The EURO TERVIHT project (Trace Elements Reference Values in Human Tissues) was started for evaluating, checking and suggesting harmonized procedures for the establishment of trace element reference intervals in body fluids and tissues. Unfortunately, different statistical approaches are being used in this research field making data comparison difficult and in some cases impossible. Although international organizations such as International Federation of Clinical Chemistry (IFCC) or International Union of Pure and Applied Chemistry (IUPAC) have issued recommended guidelines for reference values assessment, including the statistical data treatment, a unique format and a standardized data layout is still missing. The aim of the present study is to present a software (BioReVa) running under Microsoft Windows platform suitable for calculating the reference intervals of trace elements in body matrices. The main scope for creating an ease-of-use application was to control the data distribution, to establish the reference intervals according to the accepted recommendation, on the base of the simple statistic, to get a standard presentation of experimental data and to have an application to which further need could be integrated in future. BioReVa calculates the IFCC reference intervals as well as the coverage intervals recommended by IUPAC as a supplement to the IFCC intervals. Examples of reference values and reference intervals calculated with BioReVa software concern Pb and Se in blood; Cd, In and Cr in urine, Hg and Mo in hair of different general European populations. University of Michigan
[Study on blood pressure standard in children using the automatic sphygmomanometer].
Niida, Mami; Hataya, Hiroshi; Honda, Masataka
2015-01-01
In Japan, two treatment guidelines exist for pediatric patients with hypertension. The Guidelines for Drug Therapy in Pediatric Patients with Cardiovascular Diseases (JCS2012), by the Japanese Circulation Society, cite the stethoscopy-based American guidelines. The Guidelines for the Management of Hypertension (JSH2009), by the Japanese Society of Hypertension, focus on Japanese data obtained from automated sphygmomanometry. The frequent use of automated sphygmomanometers in clinical practice implies that the JSH2009 guidelines might be better; however with strict low reference values for the diastolic phase, overtreatment may result. Only the Japanese Circulation Society's guidelines include a therapeutic strategy, and the Chronic Kidney Disease (CKD) Guide, CKD Guidelines, and school urinary screening tests all cite these guidelines on stethoscopy-based blood pressure determination. Stethoscopy should be conducted during a medical examination; however, due to limited time in clinical practice, most physicians use automated sphygmomanometers while nevertheless relying on the Japanese Circulation Society reference values--which are stethoscopy-based. To find a compromise, we compared reference values in Japan with those from South Korea (automated sphygmomanometer-based) and those from the United States (stethoscopy-based). Moreover, we examined the results of recent accuracy tests for automated sphygmomanometers. Although the JSH2009 reference values for the systolic phase were consistent with those in the United States (stethoscopy-based), the reference values for the diastolic phase were lower. We observed the same tendency when comparing JSH2009 reference values with those in South Korea (automated sphygmomanometer-based). Conversely, there were only small differences between automated sphygmomanometry and mercury measurement, and we found it was possible to substitute the values from automated sphygmomanometry for stethoscopy. A large-scale study that takes into account patient height, measurement method, and treatment criteria is required to establish appropriate reference values. Even if automated sphygmomanometry is used until appropriate values are established, we consider the criteria provided in the American guidelines as appropriate.
Brown, Kerry A; de Wit, Liesbeth; Timotijevic, Lada; Sonne, Anne-Mette; Lähteenmäki, Liisa; Brito Garcia, Noé; Jeruszka-Bielak, Marta; Sicińska, Ewa; Moore, Alana N; Lawrence, Mark; Raats, Monique M
2015-06-01
Transparent evidence-based decision making has been promoted worldwide to engender trust in science and policy making. Yet, little attention has been given to transparency implementation. The degree of transparency (focused on how uncertain evidence was handled) during the development of folate and vitamin D Dietary Reference Values was explored in three a priori defined areas: (i) value request; (ii) evidence evaluation; and (iii) final values. Qualitative case studies (semi-structured interviews and desk research). A common protocol was used for data collection, interview thematic analysis and reporting. Results were coordinated via cross-case synthesis. Australia and New Zealand, Netherlands, Nordic countries, Poland, Spain and UK. Twenty-one interviews were conducted in six case studies. Transparency of process was not universally observed across countries or areas of the recommendation setting process. Transparency practices were most commonly seen surrounding the request to develop reference values (e.g. access to risk manager/assessor problem formulation discussions) and evidence evaluation (e.g. disclosure of risk assessor data sourcing/evaluation protocols). Fewer transparency practices were observed to assist with handling uncertainty in the evidence base during the development of quantitative reference values. Implementation of transparency policies may be limited by a lack of dedicated resources and best practice procedures, particularly to assist with the latter stages of reference value development. Challenges remain regarding the best practice for transparently communicating the influence of uncertain evidence on the final reference values. Resolving this issue may assist the evolution of nutrition risk assessment and better inform the recommendation setting process.
Pottel, Hans; Hoste, Liesbeth; Delanaye, Pierre
2015-05-01
The chronic kidney disease (CKD) classification system for children is similar to that for adults, with both mainly based on estimated glomerular filtration rate (eGFR) combined with fixed cut-off values. The main cut-off eGFR value used to define CKD is 60 mL/min/1.73 m(2), a value that is also applied for children older than 2 years of age, adolescents and young adults. Based on a literature search, we evaluated inclusion criteria for eGFR in clinical trials or research studies on CKD for children. We also collected information on direct measurements of GFR (mGFR) in children and adolescents, with the aim to estimate the normal reference range for GFR. Using serum creatinine (Scr) normal reference values and Scr-based eGFR-equations, we also evaluated the correspondence between Scr normal reference values and (e)GFR normal reference values. Based on our literature search, the inclusion of children in published CKD studies has been based on cut-off values for eGFR of >60 mL/min/1.73 m(2). The lower reference limits for mGFR far exceed this adult threshold. Using eGFR values calculated using Scr-based formulas, we found that abnormal Scr levels in children already correspond to eGFR values that are below a cut-off of 75 mL/min/1.73 m(2). Abnormal GFR in children, adolescents and young adults starts below 75 mL/min/1.73 m(2), and as abnormality is a sign of disease, we recommend referring children, adolescents and young adults with an (e)GFR of <75 mL/min/1.73 m(2) for further clinical assessment.
Schlenz, H; Intemann, T; Wolters, M; González-Gil, E M; Nappo, A; Fraterman, A; Veidebaum, T; Molnar, D; Tornaritis, M; Sioen, I; Mårild, S; Iacoviello, L; Ahrens, W
2014-09-01
C-reactive protein (CRP) is involved in a wide range of diseases. It is a powerful marker for inflammatory processes used for diagnostic and monitoring purposes. We aimed to establish reference values as data on the distribution of serum CRP levels in young European children are scarce. Reference values of high-sensitivity CRP concentrations were calculated for 9855 children aged 2.0-10.9 years, stratified by age and sex. The children were recruited during the population-based European IDEFICS study (Identification and prevention of Dietary- and lifestyle-induced health Effects in Children and infantS) with 18 745 participants recruited from 2007 to 2010. In 44.1% of the children, CRP values were below or equal the detection limit of 0.2 mg/l. Median CRP concentrations showed a slight negative age trend in boys and girls, whereas serum CRP values were slightly higher in girls than in boys across all age groups. Our population-based reference values of CRP may guide paediatric practice as elevated values may require further investigation or treatment. Therefore, the presented reference values represent a basis for clinical evaluation and for future research on risk assessment of diseases associated with increased CRP levels among children.
The conventional tuning fork as a quantitative tool for vibration threshold.
Alanazy, Mohammed H; Alfurayh, Nuha A; Almweisheer, Shaza N; Aljafen, Bandar N; Muayqil, Taim
2018-01-01
This study was undertaken to describe a method for quantifying vibration when using a conventional tuning fork (CTF) in comparison to a Rydel-Seiffer tuning fork (RSTF) and to provide reference values. Vibration thresholds at index finger and big toe were obtained in 281 participants. Spearman's correlations were performed. Age, weight, and height were analyzed for their covariate effects on vibration threshold. Reference values at the fifth percentile were obtained by quantile regression. The correlation coefficients between CTF and RSTF values at finger/toe were 0.59/0.64 (P = 0.001 for both). Among covariates, only age had a significant effect on vibration threshold. Reference values for CTF at finger/toe for the age groups 20-39 and 40-60 years were 7.4/4.9 and 5.8/4.6 s, respectively. Reference values for RSTF at finger/toe for the age groups 20-39 and 40-60 years were 6.9/5.5 and 6.2/4.7, respectively. CTF provides quantitative values that are as good as those provided by RSTF. Age-stratified reference data are provided. Muscle Nerve 57: 49-53, 2018. © 2017 Wiley Periodicals, Inc.
[Diagnostic reference levels in interventional radiology].
Vañó Carruana, E; Fernández Soto, J M; Sánchez Casanueva, R M; Ten Morón, J I
2013-12-01
This article discusses the diagnostic reference levels for radiation exposure proposed by the International Commission on Radiological Protection (ICRP) to facilitate the application of the optimization criteria in diagnostic imaging and interventional procedures. These levels are normally established as the third quartile of the dose distributions to patients in an ample sample of centers and are supposed to be representative of good practice regarding patient exposure. In determining these levels, it is important to evaluate image quality as well to ensure that it is sufficient for diagnostic purposes. When the values for the dose received by patients are systematically higher or much lower than the reference levels, an investigation should determine whether corrective measures need to be applied. The European and Spanish regulations require the use of these reference values in quality assurance programs. For interventional procedures, the dose area product (or kerma area product) values are usually used as reference values together with the time under fluoroscopy and the total number of images acquired. The most modern imaging devices allow the value of the accumulated dose at the entrance to the patient to be calculated to optimize the distribution of the dose on the skin. The ICRP recommends that the complexity of interventional procedures be taken into account when establishing reference levels. In the future, diagnostic imaging departments will have automatic systems to manage patient dosimetric data; these systems will enable continuous dosage auditing and alerts about individual procedures that might involve doses several times above the reference values. This article also discusses aspects that need to be clarified to take better advantage of the reference levels in interventional procedures. Copyright © 2013 SERAM. Published by Elsevier Espana. All rights reserved.
Qi, Haiping; Coplen, Tyler B.; Tarbox, Lauren V.; Lorenz, Jennifer M.; Scholl, Martha A.
2014-01-01
A new secondary isotopic reference material has been prepared from Puerto Rico precipitation, which was filtered, homogenised, loaded into glass ampoules, sealed with a torch, autoclaved to eliminate biological activity, and calibrated by dual-inlet isotope-ratio mass spectrometry. This isotopic reference material, designated as USGS48, is intended to be one of two isotopic reference waters for daily normalisation of stable hydrogen (δ2H) and stable oxygen (δ18O) isotopic analysis of water with a mass spectrometer or a laser absorption spectrometer. The δ2H and δ18O values of this reference water are−2.0±0.4 and−2.224±0.012 ‰, respectively, relative to Vienna Standard Mean Ocean Water on scales normalised such that the δ2H and δ18O values of Standard Light Antarctic Precipitation reference water are−428 and−55.5 ‰, respectively. Each uncertainty is an estimated expanded uncertainty (U=2uc) about the reference value that provides an interval that has about a 95 % probability of encompassing the true value. This isotopic reference water is available by the case of 144 glass ampoules containing 5 mL of water in each ampoule.
Kodama, Ayuto; Kume, Yu; Tsugaruya, Megumi; Ishikawa, Takashi
2016-01-01
The circadian rhythm in older adults is commonly known to change with a decrease in physical activity. However, the association between circadian rhythm metrics and physical activity remains unclear. The objective of this study was to examine circadian activity patterns in older people with and without dementia and to determine the amount of physical activity conducive to a good circadian measurement. Circadian parameters were collected from 117 older community-dwelling people (66 subjects without dementia and 52 subjects with dementia); the parameters were measured continuously using actigraphy for 7 days. A receiver operating characteristic (ROC) curve was applied to determine reference values for the circadian rhythm parameters, consisting of interdaily stability (IS), intradaily variability (IV), and relative amplitude (RA), in older subjects. The ROC curve revealed reference values of 0.55 for IS, 1.10 for IV, and 0.82 for RA. In addition, as a result of the ROC curve in the moderate-to-vigorous physical Activity (MVPA) conducive to the reference value of the Non-parametric Circadian Rhythm Analysis per day, the optimal reference values were 51 minutes for IV and 55 minutes for RA. However, the IS had no classification accuracy. Our results demonstrated the reference values derived from the circadian parameters of older Japanese population with or without dementia. Also, we determined the MVPA conducive to a good circadian rest-active pattern. This reference value for physical activity conducive to a good circadian rhythm might be useful for developing a new index for health promotion in the older community-dwelling population.
Effect of defuzzification method of fuzzy modeling
NASA Astrophysics Data System (ADS)
Lapohos, Tibor; Buchal, Ralph O.
1994-10-01
Imprecision can arise in fuzzy relational modeling as a result of fuzzification, inference and defuzzification. These three sources of imprecision are difficult to separate. We have determined through numerical studies that an important source of imprecision is the defuzzification stage. This imprecision adversely affects the quality of the model output. The most widely used defuzzification algorithm is known by the name of `center of area' (COA) or `center of gravity' (COG). In this paper, we show that this algorithm not only maps the near limit values of the variables improperly but also introduces errors for middle domain values of the same variables. Furthermore, the behavior of this algorithm is a function of the shape of the reference sets. We compare the COA method to the weighted average of cluster centers (WACC) procedure in which the transformation is carried out based on the values of the cluster centers belonging to each of the reference membership functions instead of using the functions themselves. We show that this procedure is more effective and computationally much faster than the COA. The method is tested for a family of reference sets satisfying certain constraints, that is, for any support value the sum of reference membership function values equals one and the peak values of the two marginal membership functions project to the boundaries of the universe of discourse. For all the member sets of this family of reference sets the defuzzification errors do not get bigger as the linguistic variables tend to their extreme values. In addition, the more reference sets that are defined for a certain linguistic variable, the less the average defuzzification error becomes. In case of triangle shaped reference sets there is no defuzzification error at all. Finally, an alternative solution is provided that improves the performance of the COA method.
[Reference values for lead levels in blood for the urban population].
Paolielo, M M; Gutierrez, P R; Turini, C A; Matsuo, T; Mezzaroba, L; Barbosa, D S; Alvarenga, A L; Carvalho, S R; Figueiroa, G A; Leite, V G; Gutierrez, A C; Nogueira, K B; Inamine, W A; Zavatti, A M
1997-04-01
The lead reference values for blood used in Brazil come from studies conducted in other countries, where socioeconomic, clinical, nutritional and occupational conditions are significantly different. In order to guarantee an accurate biomonitoring of the population which is occupationally exposed to lead, a major health concern of the studied community, reference values for individuals who are not occupationally exposed and who live in the southern region of the city were established. The sample was composed of 206 subjects of at least 15 years of age. Various strategies were employed to assure good-quality sampling. Subjects who presented values outside clinical or laboratory norms were excluded, as well as those whose specific activities might interfere with the results. Lead reference values for blood were found to be from 2.40 to 16.6 micrograms.dL-1, obtained by the interval x +/- 2s (where x is the mean and s is the standard deviation form observed values) and the median was 7.9 micrograms.dL-1.
Ruediger, T M; Allison, S C; Moore, J M; Wainner, R S
2014-09-01
The purposes of this descriptive and exploratory study were to examine electrophysiological measures of ulnar sensory nerve function in disease free adults to determine reliability, determine reference values computed with appropriate statistical methods, and examine predictive ability of anthropometric variables. Antidromic sensory nerve conduction studies of the ulnar nerve using surface electrodes were performed on 100 volunteers. Reference values were computed from optimally transformed data. Reliability was computed from 30 subjects. Multiple linear regression models were constructed from four predictor variables. Reliability was greater than 0.85 for all paired measures. Responses were elicited in all subjects; reference values for sensory nerve action potential (SNAP) amplitude from above elbow stimulation are 3.3 μV and decrement across-elbow less than 46%. No single predictor variable accounted for more than 15% of the variance in the response. Electrophysiologic measures of the ulnar sensory nerve are reliable. Absent SNAP responses are inconsistent with disease free individuals. Reference values recommended in this report are based on appropriate transformations of non-normally distributed data. No strong statistical model of prediction could be derived from the limited set of predictor variables. Reliability analyses combined with relatively low level of measurement error suggest that ulnar sensory reference values may be used with confidence. Copyright © 2014 Elsevier Masson SAS. All rights reserved.
Recommended energy and nutrients intakes in the European Union: 2008-2016
García Gabarra, Antoni; Castellà Soley, Marta; Calleja Fernández, Alicia
2017-03-30
The aim of this document is to refl ect the changes happened in the European Union legislation and the opinions of the European Food Safety Authority in relation to the nutritional labeling on food, the reference values for energy, macronutrients and micronutrients, and the tolerable upper safe levels. The European legislation in force uses the labeling reference values established by the Scientific Committee on Food in 2003. There would be advisable an update of them from the reference values for vitamins and minerals established by the European Food Safety Authority. Equally, there would be good to include reference labeling values for polyunsaturated fatty acids, dietary fiber and choline, and specific reference labeling values for children from 6 to 36 months. For vitamins and minerals there would be desirable the revision of tolerable upper safe levels and the establishment of maximum amounts allowed in fortified food and food supplements in the European Union; its absence might represent a risk in some population groups for an excessive and unsafe intake of certain minerals and vitamins.
Lorenz, Jennifer M.; Tarbox, Lauren V.; Buck, Bryan; Qi, Haiping; Coplen, Tyler B.
2014-01-01
RATIONALE As a result of the scarcity of isotopic reference waters for daily use, a new secondary isotopic reference material for international distribution has been prepared from drinking water collected from the Biscayne aquifer in Ft. Lauderdale, Florida. METHODS This isotopic reference water was filtered, homogenized, loaded into glass ampoules, sealed with a torch, autoclaved to eliminate biological activity, and measured by dual-inlet isotope-ratio mass spectrometry. This reference material is available by the case of 144 glass ampoules containing either 4 mL or 5 mL of water in each ampoule. RESULTS The δ2H and δ18O values of this reference material are –10.3 ± 0.4 ‰ and –2.238 ± 0.011 ‰, respectively, relative to VSMOW, on scales normalized such that the δ2H and δ18O values of SLAP reference water are, respectively, –428 and –55.5 ‰. Each uncertainty is an estimated expanded uncertainty (U = 2uc) about the reference value that provides an interval that has about a 95 % probability of encompassing the true value. CONCLUSIONS This isotopic reference material, designated as USGS45, is intended as one of two isotopic reference waters for daily normalization of stable hydrogen and oxygen isotopic analysis of water with an isotope-ratio mass spectrometer or a laser absorption spectrometer.
Ng, Chaan S.; Hobbs, Brian P.; Wei, Wei; Anderson, Ella F.; Herron, Delise H.; Yao, James C.; Chandler, Adam G.
2014-01-01
Objective To assess the effects of sampling interval (SI) of CT perfusion acquisitions on CT perfusion values in normal liver and liver metastases from neuroendocrine tumors. Methods CT perfusion in 16 patients with neuroendocrine liver metastases were analyzed by distributed parameter modeling to yield tissue blood flow, blood volume, mean transit time, permeability, and hepatic arterial fraction, for tumor and normal liver. CT perfusion values for the reference sampling interval of 0.5s (SI0.5) were compared with those of SI datasets of 1s, 2s, 3s and 4s, using mixed-effects model analyses. Results Increases in SI beyond 1s were associated with significant and increasing departures of CT perfusion parameters from reference values at SI0.5 (p≤0.0009). CT perfusion values deviated from reference with increasing uncertainty with increasing SIs. Findings for normal liver were concordant. Conclusion Increasing SIs beyond 1s yield significantly different CT perfusion parameter values compared to reference values at SI0.5. PMID:25626401
[Reference values of energy for the Venezuelan population].
Landaeta-Jiménez, Maritza; Aliaga, Carla; Sifontes, Yaritza; Vásquez, Maura; Ramírez, Guillermo; Falque Madrid, Luís; Herrera, Marianella; María Reyes, Ana; Emilia, Elzakem; Herrera, Ctor; Bernal, Jennifer
2013-12-01
The project of updating the Venezuelan energy reference values respond to the recommendations made by an FAO experts committee, several decades ago for the countries assuming this work. Because of the dramatic changes experienced globally regarding energy intake/expenditure and particularly variations on the Venezuelan nutritional scenario with the presence of "the double burden of malnutrition" it a review of Energy Reference Values (VRE) from a more integral approach is pertinent. This report follows the methodology proposed by FAO/WHO/UNU 2004 experts committee and energy reference values were established by group of age and gender, also average energy values for Venezuelan population were obtained. For calculation of these requirements, the energy expenditure was included by taking into account Basal Metabolic Rate and physical activity level for some specific groups. The score average values updated in 2012 of 2.200 kcal/dia reported to be lower than those of 2000 at all ages for masculine gender except for the 16-17 age group and for feminine gender just until ages 10-12 years and from there are slightly above the values obtained in 2000.
Hermoso, Maria; Tabacchi, Garden; Iglesia-Altaba, Iris; Bel-Serrat, Silvia; Moreno-Aznar, Luis A; García-Santos, Yurena; García-Luzardo, Ma del Rosario; Santana-Salguero, Beatriz; Peña-Quintana, Luis; Serra-Majem, Lluis; Moran, Victoria Hall; Dykes, Fiona; Decsi, Tamás; Benetou, Vassiliki; Plada, Maria; Trichopoulou, Antonia; Raats, Monique M; Doets, Esmée L; Berti, Cristiana; Cetin, Irene; Koletzko, Berthold
2010-10-01
This paper presents a review of the current knowledge regarding the macro- and micronutrient requirements of infants and discusses issues related to these requirements during the first year of life. The paper also reviews the current reference values used in European countries and the methodological approaches used to derive them by a sample of seven European and international authoritative committees from which background scientific reports are available. Throughout the paper, the main issues contributing to disparities in micronutrient reference values for infants are highlighted. The identification of these issues in relation to the specific physiological aspects of infants is important for informing future initiatives aimed at providing standardized approaches to overcome variability of micronutrient reference values across Europe for this age group. © 2010 Blackwell Publishing Ltd.
Mekonnen, Zewdie; Amuamuta, Asmare; Mulu, Wondemagegn; Yimer, Mulat; Zenebe, Yohannes; Adem, Yesuf; Abera, Bayeh; Gebeyehu, Wondemu; Gebregziabher, Yakob
2017-01-01
Reference interval is crucial for disease screening, diagnosis, monitoring, progression and treatment efficacy. Due to lack of locally derived reference values for the parameters, clinicians use reference intervals derived from western population. But, studies conducted in different African countries have indicated differences between locally and western derived reference values. Different studies also indicated considerable variation in clinical chemistry reference intervals by several variables such as age, sex, geographical location, environment, lifestyle and genetic variation. This study aimed to determine the reference intervals of common clinical chemistry parameters of the community of Gojjam Zones, Northwest Ethiopia. Population based cross-sectional study was conducted from November 2015 to December 2016 in healthy adult populations of Gojjam zone. Data such as, medical history, physical examination and socio-demographic data were collected. In addition, laboratory investigations were undertaken to screen the population. Clinical chemistry parameters were measured using Mindray BS 200 clinical chemistry autoanalyzer as per the manufacturer's instructions. Descriptive statistics was used to calculate mean, median and 95th percentiles. Independent sample T-test and one way ANOVA were used to see association between variables. After careful screening of a total of 799 apparently healthy adults who were consented for this study, complete data from 446 (224 females and 222 males) were included for the analysis. The mean age of both the study participants was 28.8 years. Males had high (P<0.05) mean and 2.5th-97.5th percentile ranges of ALT, AST, ALP, creatinine and direct bilirubin. The reference intervals of amylase, LDH, total protein and total bilirubin were not significantly different between the two sex groups (P>0.05). Mean, median, 95% percentile values of AST, ALP, amylase, LDH, creatinine, total protein, total bilirubin, and direct bilirubin across all age groups of participants were similar (P>0.05). But, there was a significant difference in the value of ALT (P<0.05). The reference intervals of ALT, total protein and creatinine were significantly (P<0.05) high in people having monthly income >1500 ETB compared to those with low monthly income. Significant (P<0.05) higher values of the ALT, ALP and total protein were observed in people living in high land compared to low land residences. The study showed that some of the common clinical chemistry parameters reference intervals of healthy adults in Gojjam zones were higher than the reference intervals generated from developed countries. Therefore, strict adherence to the reference values generated in developed countries could lead to inappropriate diagnosis and treatment of patients. There was also variation of reference interval values based on climate, gender, age, monthly income and geographical locations. Therefore, further study is required to establish reference intervals for Ethiopian population.
Estimation of reference intervals from small samples: an example using canine plasma creatinine.
Geffré, A; Braun, J P; Trumel, C; Concordet, D
2009-12-01
According to international recommendations, reference intervals should be determined from at least 120 reference individuals, which often are impossible to achieve in veterinary clinical pathology, especially for wild animals. When only a small number of reference subjects is available, the possible bias cannot be known and the normality of the distribution cannot be evaluated. A comparison of reference intervals estimated by different methods could be helpful. The purpose of this study was to compare reference limits determined from a large set of canine plasma creatinine reference values, and large subsets of this data, with estimates obtained from small samples selected randomly. Twenty sets each of 120 and 27 samples were randomly selected from a set of 1439 plasma creatinine results obtained from healthy dogs in another study. Reference intervals for the whole sample and for the large samples were determined by a nonparametric method. The estimated reference limits for the small samples were minimum and maximum, mean +/- 2 SD of native and Box-Cox-transformed values, 2.5th and 97.5th percentiles by a robust method on native and Box-Cox-transformed values, and estimates from diagrams of cumulative distribution functions. The whole sample had a heavily skewed distribution, which approached Gaussian after Box-Cox transformation. The reference limits estimated from small samples were highly variable. The closest estimates to the 1439-result reference interval for 27-result subsamples were obtained by both parametric and robust methods after Box-Cox transformation but were grossly erroneous in some cases. For small samples, it is recommended that all values be reported graphically in a dot plot or histogram and that estimates of the reference limits be compared using different methods.
Experimental validation of beam quality correction factors for proton beams
NASA Astrophysics Data System (ADS)
Gomà, Carles; Hofstetter-Boillat, Bénédicte; Safai, Sairos; Vörös, Sándor
2015-04-01
This paper presents a method to experimentally validate the beam quality correction factors (kQ) tabulated in IAEA TRS-398 for proton beams and to determine the kQ of non-tabulated ionization chambers (based on the already tabulated values). The method is based exclusively on ionometry and it consists in comparing the reading of two ionization chambers under the same reference conditions in a proton beam quality Q and a reference beam quality 60Co. This allows one to experimentally determine the ratio between the kQ of the two ionization chambers. In this work, 7 different ionization chamber models were irradiated under the IAEA TRS-398 reference conditions for 60Co beams and proton beams. For the latter, the reference conditions for both modulated beams (spread-out Bragg peak field) and monoenergetic beams (pseudo-monoenergetic field) were studied. For monoenergetic beams, it was found that the experimental kQ values obtained for plane-parallel chambers are consistent with the values tabulated in IAEA TRS-398; whereas the kQ values obtained for cylindrical chambers are not consistent—being higher than the tabulated values. These results support the suggestion (of previous publications) that the IAEA TRS-398 reference conditions for monoenergetic proton beams should be revised so that the effective point of measurement of cylindrical ionization chambers is taken into account when positioning the reference point of the chamber at the reference depth. For modulated proton beams, the tabulated kQ values of all the ionization chambers studied in this work were found to be consistent with each other—except for the IBA FC65-G, whose experimental kQ value was found to be 0.6% lower than the tabulated one. The kQ of the PTW Advanced Markus chamber, which is not tabulated in IAEA TRS-398, was found to be 0.997 ± 0.042 (k = 2), based on the tabulated value of the PTW Markus chamber.
[Muscle strength of the cervical and lumbar spine in triathletes].
Miltner, O; Siebert, C H; Müller-Rath, R; Kieffer, O
2010-12-01
The goal of this study was to analyse the muscle strength of the cervical and lumbar spine in ironman triathletes. The values were compared to the results obtained from a reference group. The test of the triathletes was carried out in an attempt to define a specific strength profile for these athletes. In this study, 20 long-distance triathletes (∅ 37.3 ± 7.6 years of age, ∅ 1.80 ± 0.1 m, ∅ 73.7 ± 6.0 kg) were evaluated with regard to their individual and sport-specific strengths of the cervical spine in 2 planes and of the trunk strengths in all 3 planes of motion. The trunk strength profile of the triathletes revealed good average results in the trunk extensors and the lateral flexors of the left trunk. The reference group is the data base of the company Proxomed®, Alzenau. It is based on results of 1045 untrained, symptom-free subjects of different ages. Lumbar extension: The extension of the force values shows no significant difference from the reference group. Lumbar flexion: The flexion tests show highly significantly lower force values (5.025 ± 0.81 N/kg vs. 6.67 ± 0.6 N/kg) than the reference group. Flexion/extension: In the sagittal plane values for the triathletes demonstrate an imbalance in muscle strength ratios. The abdominal muscles turn in relation to the back extensor muscles too weakly to be very significant. Lumbar rotation: The force values of the athletes in both directions (right: 6.185 ± 1.46 N/kg, left: 7.1 ± 1.57 N/kg vs. 10.05 ± 0.34 N/kg) are highly significantly (p ≤ 0.001) lower than the reference values. Ratio of rotation left/right: The ratio of left/right rotation in the reference group is set at 1 and thus shows an equally strong force level between the two sides. Lumbar lateral flexion: The triathletes do not show any significant differences between the force values. Compared to the reference group there is no significant difference to the left side flexion. In the lateral bending the athletes have significantly better values than the reference group. Ratio of lateral left/right: In the reference group the ratio is set at 1. For triathletes, it shows an average value of 0.93. This difference is not significant. Cervical extension: The extension of the force values (1.96 ± 0.59 N/kg vs. 3.03 ± 0.24 N/kg) shows a highly significant difference from the reference group. Cervical flexion: In flexion (1.3 ± 0.42 N/kg vs. 2.17 ± 0.22 N/kg) triathletes have highly significantly lower strength values than the reference group. Flexion/extension: The triathletes did not differ significantly from the reference values (0.69 ± 0.23 and 0.72 ± 0.08). Lateral cervical spine: In comparison to the reference group (left: 1.67 ± 0.48 N/kg, right: 1.55 ± 0.46 N/kg vs. 2.36 ± 0.15 N/kg) in which there is left/right lateral flexion, there is a highly significant difference. Right lateral flexion is weaker than the left. Ratio of lateral left/right: The triathletes have a significant imbalance in the lateral flexion of the cervical spine compared to the reference group (1.07 ± 0.15 to 1). In conclusion, in the triathlon there is a specific stress that is obviously not an adequate stimulus for the muscles of the cervical spine in order to achieve a balanced musculature and the athletes should be advised to practice a preventive approach with regard to these areas. © Georg Thieme Verlag KG Stuttgart · New York.
Values for Human-to-Human Reference.
ERIC Educational Resources Information Center
Gorman, Michael
2001-01-01
Defines "values" and lists the eight values (stewardship, service, intellectual freedom, rationalism, literacy and learning, equity of access, privacy, democracy) derived by the author in an earlier work. Gives a brief history of the evolution of human-to-human reference service and discusses its future. Relates each of the author's eight values…
Calhoun, Peter; Lum, John; Beck, Roy W; Kollman, Craig
2013-09-01
Knowledge of the accuracy of continuous glucose monitoring (CGM) devices is important for its use as a management tool for individuals with diabetes and for its use to assess outcomes in clinical studies. Using data from several inpatient studies, we compared the accuracy of two sensors, the Medtronic Enlite™ using MiniMed Paradigm(®) Veo™ calibration and the Sof-Sensor(®) glucose sensor using Guardian(®) REAL-Time CGM calibration (all from Medtronic Diabetes, Northridge, CA). Nocturnal data were analyzed from eight inpatient studies in which both CGM and reference glucose measurements were available. The analyses included 1,666 CGM-reference paired glucose values for the Enlite in 54 participants over 69 nights and 3,627 paired values for the Sof-Sensor in 66 participants over 91 nights. The Enlite sensor tended to report glucose levels lower than the reference over the entire range of glucose values, whereas the Sof-Sensor values tended to be higher than reference values in the hypoglycemic range and lower than reference values in the hyperglycemic range. The overall median sensor-reference difference was -15 mg/dL for the Enlite and -1 mg/dL for the Sof-Sensor (P<0.001). The median relative absolute difference was 15% for the Enlite versus 12% for the Sof-Sensor (P=0.06); 66% of Enlite values and 73% of Sof-Sensor values met International Organization for Standardization criteria. We found that the Enlite tended to be biased low over the entire glucose range, whereas the Sof-Sensor showed the more typical sensor pattern of being biased high in the hypoglycemic range and biased low in the hyperglycemic range.
Leen, Wilhelmina G.; Willemsen, Michèl A.; Wevers, Ron A.; Verbeek, Marcel M.
2012-01-01
Cerebrospinal fluid (CSF) analysis is an important tool in the diagnostic work-up of many neurological disorders, but reference ranges for CSF glucose, CSF/plasma glucose ratio and CSF lactate based on studies with large numbers of CSF samples are not available. Our aim was to define age-specific reference values. In 1993 The Nijmegen Observational CSF Study was started. Results of all CSF samples that were analyzed between 1993 and 2008 at our laboratory were systematically collected and stored in our computerized database. After exclusion of CSF samples with an unknown or elevated erythrocyte count, an elevated leucocyte count, elevated concentrations of bilirubin, free hemoglobin, or total protein 9,036 CSF samples were further studied for CSF glucose (n = 8,871), CSF/plasma glucose ratio (n = 4,516) and CSF lactate values (n = 7,614). CSF glucose, CSF/plasma glucose ratio and CSF lactate were age-, but not sex dependent. Age-specific reference ranges were defined as 5–95th percentile ranges. CSF glucose 5th percentile values ranged from 1.8 to 2.9 mmol/L and 95th percentile values from 3.8 to 5.6 mmol/L. CSF/plasma glucose ratio 5th percentile values ranged from 0.41 to 0.53 and 95th percentile values from 0.82 to 1.19. CSF lactate 5th percentile values ranged from 0.88 to 1.41 mmol/L and 95th percentile values from 2.00 to 2.71 mmol/L. Reference ranges for all three parameters were widest in neonates and narrowest in toddlers, with lower and upper limits increasing with age. These reference values allow a reliable interpretation of CSF results in everyday clinical practice. Furthermore, hypoglycemia was associated with an increased CSF/plasma glucose ratio, whereas hyperglycemia did not affect the CSF/plasma glucose ratio. PMID:22880096
A National Trial on Differences in Cerebral Perfusion Pressure Values by Measurement Location.
McNett, Molly M; Bader, Mary Kay; Livesay, Sarah; Yeager, Susan; Moran, Cristina; Barnes, Arianna; Harrison, Kimberly R; Olson, DaiWai M
2018-04-01
Cerebral perfusion pressure (CPP) is a key parameter in management of brain injury with suspected impaired cerebral autoregulation. CPP is calculated by subtracting intracranial pressure (ICP) from mean arterial pressure (MAP). Despite consensus on importance of CPP monitoring, substantial variations exist on anatomical reference points used to measure arterial MAP when calculating CPP. This study aimed to identify differences in CPP values based on measurement location when using phlebostatic axis (PA) or tragus (Tg) as anatomical reference points. The secondary study aim was to determine impact of differences on patient outcomes at discharge. This was a prospective, repeated measures, multi-site national trial. Adult ICU patients with neurological injury necessitating ICP and CPP monitoring were consecutively enrolled from seven sites. Daily MAP/ICP/CPP values were gathered with the arterial transducer at the PA, followed by the Tg as anatomical reference points. A total of 136 subjects were enrolled, resulting in 324 paired observations. There were significant differences for CPP when comparing values obtained at PA and Tg reference points (p < 0.000). Differences remained significant in repeated measures model when controlling for clinical factors (mean CPP-PA = 80.77, mean CPP-Tg = 70.61, p < 0.000). When categorizing CPP as binary endpoint, 18.8% of values were identified as adequate with PA values, yet inadequate with CPP values measured at the Tg. Findings identify numerical differences for CPP based on anatomical reference location and highlight importance of a standard reference point for both clinical practice and future trials to limit practice variations and heterogeneity of findings.
Acceptable Tolerances for Matching Icing Similarity Parameters in Scaling Applications
NASA Technical Reports Server (NTRS)
Anderson, David N.
2003-01-01
This paper reviews past work and presents new data to evaluate how changes in similarity parameters affect ice shapes and how closely scale values of the parameters should match reference values. Experimental ice shapes presented are from tests by various researchers in the NASA Glenn Icing Research Tunnel. The parameters reviewed are the modified inertia parameter (which determines the stagnation collection efficiency), accumulation parameter, freezing fraction, Reynolds number, and Weber number. It was demonstrated that a good match of scale and reference ice shapes could sometimes be achieved even when values of the modified inertia parameter did not match precisely. Consequently, there can be some flexibility in setting scale droplet size, which is the test condition determined from the modified inertia parameter. A recommended guideline is that the modified inertia parameter be chosen so that the scale stagnation collection efficiency is within 10 percent of the reference value. The scale accumulation parameter and freezing fraction should also be within 10 percent of their reference values. The Weber number based on droplet size and water properties appears to be a more important scaling parameter than one based on model size and air properties. Scale values of both the Reynolds and Weber numbers need to be in the range of 60 to 160 percent of the corresponding reference values. The effects of variations in other similarity parameters have yet to be established.
Kaafarani, Mirna; Schroer, Christian; Takken, Tim
2017-12-01
Hemodynamic responses to exercise are used as markers of diagnosis for cardiac diseases, systolic blood pressure (SBP) especially. However, the reference values for SBP in children at peak exertion level are outdated. This study aimed to establish current reference values for SBP, rate pressure product (RPP), and circulatory power (CircP). Data from children who previously underwent cardiopulmonary exercise testing were categorized as healthy (N = 184; age 12.6 ± 2.9 years), and CoA patients (N = 25; age 13.0 ± 3.2 years). With the Lambda-Mu-Sigma (LMS) method, percentile curves were made for SBP, CircP, and RPP in function of peak work rate (Wpeak). Data of CoA patients were used to validate the reference values. Wpeak was the best predictor of peak SBP during exercise. The prediction equations for SBP, CircP and RPP were: (0.2853 x Wpeak) + 111.46; (10.56 x Wpeak) + 2550.2 and (61.879 x Wpeak) + 19.887, respectively. CoA patients showed significantly increased values for peak SBP (Z-score 1.063 ± 1.347). This study provides reference values for SBP, RPP, and CircP at peak exercise. These values can be used for objective evaluation of participants 6-18 years of age in a Dutch population.
Study of extremely low frequency electromagnetic fields in infant incubators.
Cermáková, Eleonora
2003-01-01
The aim of the work was to present the results of measurements of extremely low frequency electromagnetic fields (ELF EMF), namely the magnetic flux density, inside infant incubators, and to compare these results with the data published by other authors who point out to a possible association between leukemia or other diseases observed in newborns kept in incubators after the birth and the ELF EMF exposure in the incubator. The measured magnetic flux densities were compared with the reference values for this frequency range indicated in the European Union (EU) recommendations. The repeated measurements in incubators were made with a calibrated magnetometer EFA 300 in the frequency range of 5-30 kHz. Effective values of magnetic flux densities of ELF EMF were determined taking account of the reference values. The results of many repeated measurements showing the values of magnetic flux density in modern incubators with plastic supporting frame, were compared with those obtained in old type incubators with iron skeleton. A power frequency of 50 Hz was detected in the incubator and the ELF EMF values were by over two orders lower than the EU reference values. The paper emphasizes the need to take a special care of newborns kept in incubators even if only the sub-reference values are detected. The EU reference values are intended for the adult human population. A baby in an incubator has much smaller dimensions, higher electric conductivity and maybe trigger another mechanism of response to ELF EMF than that indicated in this paper.
WILDLIFE TOXICITY REFERENCE VALUES FOR POLYNUCLEAR AROMATIC HYDROCARBONS AND DDT
The presentation will provide an overview of the procedures used in deriving mammalian and avian wildlife toxicity reference values to be used in development of ecological soil screening levels (Eco-SSLs).
DOE Office of Scientific and Technical Information (OSTI.GOV)
Williams, L.R.
Much research has been devoted to measurement of total blood volume (TBV) and cardiac output (CO) in humans but not enough effort has been devoted to collection and reduction of results for the purpose of deriving typical or {open_quotes}reference{close_quotes} values. Identification of normal values for TBV and CO is needed not only for clinical evaluations but also for the development of biokinetic models for ultra-short-lived radionuclides used in nuclear medicine (Leggett and Williams 1989). The purpose of this report is to offer reference values for TBV and CO, along with estimates of the associated uncertainties that arise from intra- andmore » inter-subject variation, errors in measurement techniques, and other sources. Reference values are derived for basal supine CO and TBV in reference adult humans, and differences associated with age, sex, body size, body position, exercise, and other circumstances are discussed.« less
Calzada-Contreras, Adriana; Moreno-Hernández, Manuel; Castillo-Torres, Noemi Patricia; Souto-Rosillo, Guadalupe; Hernández-Juárez, Jesús; Ricardo-Moreno, María Tania; Sánchez-Fernández, Maria Guadalupe de Jesús; García-González, América; Majluf-Cruz, Abraham
2012-01-01
The blood coagulation system maintains the blood in a liquid state and bleeding and thrombosis are the manifestations of its malfunction. Blood coagulation laboratory evaluates the physiology of this system. To establish both, the reference values for several tests performed at the blood coagulation laboratory as well as the utility of the pooled plasma to perform these assays. MATERIAL AND: In this descriptive, cross-sectional, randomized study, we collected plasma from Mexican Mestizos. Each pooled plasma was prepared with the plasma from at least 20 blood donors. We performed screening and special tests and the Levey-Jennings graphs were built and interpreted after each pass. Results of the tests were analyzed and their distribution was established using the Kolmogorov-Smirnov test. To establish the reference values we used 95% confidence intervals. We collected 72 pooled plasmas. The distribution for PT, APTT, and TT tests was abnormal. Although the PT test showed a bimodal distribution it was normal for factor VII. The reference values for the hemostatic, anticoagulant, and fibrinolytic factors were different from those suggested by the manufacturers. We established the reference values for the blood coagulation tests in the adult Mexican population. We have shown that the pooled plasma must be used for the screening tests. We suggest that each clinical laboratory should establish its own reference values (at least for the screening tests). To reach this objective, we encourage the use of the pooled plasma.
2012-01-01
Background Pulsed wave (PW) Doppler echocardiography has become a routine non invasive cardiac diagnostic tool in most species. However, evaluation of intracardiac blood flow requires reference values, which are poorly documented in goats. The aim of this study was to test the repeatability, the variability, and to establish the reference values of PW measurements in healthy adult Saanen goats. Using a standardised PW Doppler echocardiographic protocol, 10 healthy adult unsedated female Saanen goats were investigated three times at one day intervals by the same observer. Mitral, tricuspid, aortic and pulmonary flows were measured from a right parasternal view, and mitral and aortic flows were also measured from a left parasternal view. The difference between left and right side measurements and the intra-observer inter-day repeatability were tested and then the reference values of PW Doppler echocardiographic parameters in healthy adult female Saanen goats were established. Results As documented in other species, all caprine PW Doppler parameters demonstrated a poor inter-day repeatability and a moderate variability. Tricuspid and pulmonary flows were best evaluated on the right side whereas mitral and aortic flows were best obtained on the left side, and reference values are reported for healthy adult Saanen goats. Conclusions PW Doppler echocardiography allows the measurement of intracardiac blood flow indices in goats. The reference values establishment will help interpreting these indices of cardiac function in clinical cardiac cases and developing animal models for human cardiology research. PMID:23067875
Age-related differences in limb fat-free mass and fat mass in healthy Chinese Adults.
Bai, Mei; Wang, Rui; Zhu, Linhao; Li, Guixin; Yuan, Dongya; Wang, Li; Jin, Tianbo
2018-05-22
Fat mass (FM) and fat-free mass (FFM) are important elements to evaluate nutritional status. The aims of this study were to establish reference values for FM and FFM of limbs, develop percentile distributions and assess age-related regional differences in body composition by multifrequency bioelectrical impedance analyzer (BIA) in healthy adults. A cross-sectional study was conducted on 3419 healthy subjects, 1595 men and 1824 women. Regional FM and FFM were measured by BIA. FM in men remained stable in both upper and lower limbs, with reference values (25-75th percentile) of 1-1.5 kg and 4.9-7.2 kg, respectively. Women's leg FM remained stable with aging (reference values 6.2-7.9 kg), increasing in their arms (0.9-1.5 kg for youngest, 1.3-2.3 kg oldest). The reference values of upper limbs FFM were 5.3-6.2 kg in men and 3.3-3.9 kg in women. Lower limbs FFM decreased with age in both gender: the reference values were 19.5-23.3 kg (men) and 13.8-15.4 kg (women) for 18-30 age group, and 17.3-20 kg and 11.2-13.1 kg, respectively, for 60+ age group. These data provided reference values of FM and FFM in both limbs, enabling the identification of age and gender-related changes in limb composition in healthy Chinese subjects.
Guo, Ying; Du, Xiang-Yang; Huang, Hua-Lan; Wang, Wei-Qing; Nie, Xin; Li, Gui-Xing
2017-11-01
To establish the reference value of high sensitive cardiac troponin T (hs-cTnT) and the efficiency of reference value in the diagnosis of chest pain. Volunteers from eight independent communities in Chengdu,Sichuan were selected with detailed records of physical examination,electrocardiogram,ultrasound examination. The level of hs-cTnT for healthy volunteers was tested to determine ninety-ninth percentile references according to sex and ages. 2 249 patients with chest pain in the emergency department of Western China Hospital from July 2009 to July 2014 were enrolled to measure the efficiency of reference value for diagnosing acute myocardial infarction (AMI). There were 1 305 volunteers included finally. Among them,the mean hs-cTnT level of male was 4.3 (3.2-5.9) ng/L,which was significantly higher than that of female 3.0 (3.0-3.1) ng/L ( P <0.01) . The correlation coefficient between age and hs-cTnT level was 0.43 (male) and 0.29 (female),and the P -value was less than 0.01. The 99th percentile values of male were 10.8 ng/L,15.4 ng/L and 19.7 ng/L for <45 yr.,45-<60 yr. and ≥60 yr.,respectively. Those values of female were 4.6 ng/L,8.9 ng/L,18.8 ng/L,respectively. There was no difference in sensitivity and specificity between the value we figured out and manufactures provided (14.0 ng/L) for those<60 yr.. For the patients ≥60 yr.,the sensitivity and negative predictive value did not show diversity ( P >0.05) but the specificity and positive predictive value showed significant difference (male: 0.67 vs. 0.56 and 0.83 vs. 0.79, P <0.05;female:0.75 vs. 0.68 and 0.74 vs. 0.69, P <0.05). We recommends that the ninety-ninth percentile reference value of patients<60 yr. should be 14.0 ng/L,while 20.0 ng/L for those patients≥60 yr.
Coplen, Tyler B.; Qi, Haiping; Tarbox, Lauren V.; Lorenz, Jennifer M.; Buck, Bryan
2015-01-01
Ice core from Greenland was melted, filtered, homogenised, loaded into glass ampoules, sealed, autoclaved to eliminate biological activity, and calibrated by dual-inlet isotope-ratio mass spectrometry. This isotopic reference material (RM), USGS46, is intended as one of two secondary isotopic reference waters for daily normalisation of stable hydrogen (δ2H) and stable oxygen (δ18O) isotopic analysis of water with a mass spectrometer or a laser absorption spectrometer. The measured δ2H and δ18O values of this reference water were −235.8 ± 0.7‰ and −29.80 ± 0.03‰, respectively, relative to VSMOW on scales normalised such that the δ2H and δ18O values of SLAP reference water are, respectively, −428 and −55.5‰. Each uncertainty is an estimated expanded uncertainty (U = 2uc) about the reference value that provides an interval that has about a 95-percent probability of encompassing the true value. This reference water is available in cases containing 144 glass ampoules that are filled with either 4 ml or 5 ml of water per ampoule.
Properties of colour reference solutions of the European Pharmacopoea in CIE L*a*b* colour space.
Subert, J; Farsa, O; Gajdosová, Z
2006-12-01
The coordinates of CIE L*a*b* uniform colour space have been acquired from the transmitance spectra of colour reference solutions of European Pharmacopoeia (Ph.Eur.). Calculation of colour differences of these solutions from purified water deltaE* gave their values in the range between 0.7 (B9 solution) to 36 (Y1 solution) CIE units. Excluding red colour reference soulutions, deltaE* values did not depend on concentrations of colour compounds linearly. Small deltaE* values founded by the brown and brownish-yellow colour reference solutions of the lowest concentrations can possibly cause some problems of visual examination of the degree of coloration of liquids according to Ph.Eur.
42 CFR 411.354 - Financial relationship, compensation, and ownership or investment interest.
Code of Federal Regulations, 2010 CFR
2010-10-01
... into account, the volume or value of referrals or other business generated by the referring physician... volume or value of referrals or other business generated by the referring physician for the entity... aggregate compensation that varies with, or takes into account, the volume or value of referrals or other...
1980-05-01
idlers, etc. Main hydraulic systems including pumps, reservoirs, accumulators, filters, valves , lines, fluid, and supports (Figure 4-40). 4-159 -4...SPEED CORRECTION Ny DN-(VALUES OF N. v VALUES OF KPR VALUES OF *111OPT VALUES OF KPN 4.OC VAL.UE LOC VALVE LOC VALU~E LOC VALUE 1207 _______ 1225...TCVT (t/c)qT 0131 TENN NUMBER OF M 0309 TF REFERRED THRUST AS A 1609 - 1616 FUNCTION OF (T/0) TF1 REFERRED N1 AS A FUNCTION 16k1 - 1648 OF (T/e) TF2
Value of Information References
Morency, Christina
2014-12-12
This file contains a list of relevant references on value of information (VOI) in RIS format. VOI provides a quantitative analysis to evaluate the outcome of the combined technologies (seismology, hydrology, geodesy) used to monitor Brady's Geothermal Field.
Reference values of aortic pulse wave velocity in the elderly.
Alecu, Cosmin; Labat, Carlos; Kearney-Schwartz, Anna; Fay, Renaud; Salvi, Paolo; Joly, Laure; Lacolley, Patrick; Vespignani, Hervé; Benetos, Athanase
2008-11-01
Increased aortic pulse wave velocity (AoPWV) is an independent predictor of cardiovascular morbidity and mortality. There are, however, no generally accepted limits for defining the normal or reference values. The aim of the present study was to define reference values for AoPWV. AoPWV was assessed using applanation tonometry (PulsePen device) in a community living ambulatory population of 455 individuals aged 60-75 years. AoPWV was studied in a group of 206 individuals without hypertension or diabetes, called the 'reference-values group' (RVG), and in a group of 249 individuals with hypertension or diabetes, called the hypertension-diabetes group (HDG). The 95th percentile of the samples was used to determine the upper limit of AoPWV reference values. Mean AoPWV was 8.7+/-2.3 m/s in the RVG and 10.2+/-2.5 m/s in the hypertension-diabetes group (P<0.0001). In the RVG, median AoPWV in the three age subgroups was 8.0 m/s (7.6-8.5) in the 60-64-, 8.0 m/s (7.5-9.0) in the 65-69- and 9.0 m/s (7.9-9.5) in the 70-75-year-old group (NS among groups). In the entire RVG, the upper bounds of the 75th and the 95th percentile of the sample's AoPWV were 10 and 13 m/s, respectively, with no difference between sexes. In elderly individuals of 60-75 years, an AoPWV value below 10 m/s, measured with the PulsePen device, can be considered as a normal value. Values of 10-13 m/s can be considered as 'high normal' or 'borderline', whereas an AoPWV above 13 m/s is frankly elevated. This study provides, for the first time in the elderly, reference values of AoPWV.
Determination of reference ranges for elements in human scalp hair.
Druyan, M E; Bass, D; Puchyr, R; Urek, K; Quig, D; Harmon, E; Marquardt, W
1998-06-01
Expected values, reference ranges, or reference limits are necessary to enable clinicians to apply analytical chemical data in the delivery of health care. Determination of references ranges is not straightforward in terms of either selecting a reference population or performing statistical analysis. In light of logistical, scientific, and economic obstacles, it is understandable that clinical laboratories often combine approaches in developing health associated reference values. A laboratory may choose to: 1. Validate either reference ranges of other laboratories or published data from clinical research or both, through comparison of patients test data. 2. Base the laboratory's reference values on statistical analysis of results from specimens assayed by the clinical reference laboratory itself. 3. Adopt standards or recommendations of regulatory agencies and governmental bodies. 4. Initiate population studies to validate transferred reference ranges or to determine them anew. Effects of external contamination and anecdotal information from clinicians may be considered. The clinical utility of hair analysis is well accepted for some elements. For others, it remains in the realm of clinical investigation. This article elucidates an approach for establishment of reference ranges for elements in human scalp hair. Observed levels of analytes from hair specimens from both our laboratory's total patient population and from a physician-defined healthy American population have been evaluated. Examination of levels of elements often associated with toxicity serves to exemplify the process of determining reference ranges in hair. In addition the approach serves as a model for setting reference ranges for analytes in a variety of matrices.
NASA Astrophysics Data System (ADS)
Kotlarski, Sven; Gutiérrez, José M.; Boberg, Fredrik; Bosshard, Thomas; Cardoso, Rita M.; Herrera, Sixto; Maraun, Douglas; Mezghani, Abdelkader; Pagé, Christian; Räty, Olle; Stepanek, Petr; Soares, Pedro M. M.; Szabo, Peter
2016-04-01
VALUE is an open European network to validate and compare downscaling methods for climate change research (http://www.value-cost.eu). A key deliverable of VALUE is the development of a systematic validation framework to enable the assessment and comparison of downscaling methods. Such assessments can be expected to crucially depend on the existence of accurate and reliable observational reference data. In dynamical downscaling, observational data can influence model development itself and, later on, model evaluation, parameter calibration and added value assessment. In empirical-statistical downscaling, observations serve as predictand data and directly influence model calibration with corresponding effects on downscaled climate change projections. We here present a comprehensive assessment of the influence of uncertainties in observational reference data and of scale-related issues on several of the above-mentioned aspects. First, temperature and precipitation characteristics as simulated by a set of reanalysis-driven EURO-CORDEX RCM experiments are validated against three different gridded reference data products, namely (1) the EOBS dataset (2) the recently developed EURO4M-MESAN regional re-analysis, and (3) several national high-resolution and quality-controlled gridded datasets that recently became available. The analysis reveals a considerable influence of the choice of the reference data on the evaluation results, especially for precipitation. It is also illustrated how differences between the reference data sets influence the ranking of RCMs according to a comprehensive set of performance measures.
Amuamuta, Asmare; Mulu, Wondemagegn; Yimer, Mulat; Zenebe, Yohannes; Adem, Yesuf; Abera, Bayeh; Gebeyehu, Wondemu; Gebregziabher, Yakob
2017-01-01
Background Reference interval is crucial for disease screening, diagnosis, monitoring, progression and treatment efficacy. Due to lack of locally derived reference values for the parameters, clinicians use reference intervals derived from western population. But, studies conducted in different African countries have indicated differences between locally and western derived reference values. Different studies also indicated considerable variation in clinical chemistry reference intervals by several variables such as age, sex, geographical location, environment, lifestyle and genetic variation. Objective This study aimed to determine the reference intervals of common clinical chemistry parameters of the community of Gojjam Zones, Northwest Ethiopia. Method Population based cross-sectional study was conducted from November 2015 to December 2016 in healthy adult populations of Gojjam zone. Data such as, medical history, physical examination and socio-demographic data were collected. In addition, laboratory investigations were undertaken to screen the population. Clinical chemistry parameters were measured using Mindray BS 200 clinical chemistry autoanalyzer as per the manufacturer’s instructions. Descriptive statistics was used to calculate mean, median and 95th percentiles. Independent sample T-test and one way ANOVA were used to see association between variables. Results After careful screening of a total of 799 apparently healthy adults who were consented for this study, complete data from 446 (224 females and 222 males) were included for the analysis. The mean age of both the study participants was 28.8 years. Males had high (P<0.05) mean and 2.5th-97.5th percentile ranges of ALT, AST, ALP, creatinine and direct bilirubin. The reference intervals of amylase, LDH, total protein and total bilirubin were not significantly different between the two sex groups (P>0.05). Mean, median, 95% percentile values of AST, ALP, amylase, LDH, creatinine, total protein, total bilirubin, and direct bilirubin across all age groups of participants were similar (P>0.05). But, there was a significant difference in the value of ALT (P<0.05). The reference intervals of ALT, total protein and creatinine were significantly (P<0.05) high in people having monthly income >1500 ETB compared to those with low monthly income. Significant (P<0.05) higher values of the ALT, ALP and total protein were observed in people living in high land compared to low land residences. Conclusion The study showed that some of the common clinical chemistry parameters reference intervals of healthy adults in Gojjam zones were higher than the reference intervals generated from developed countries. Therefore, strict adherence to the reference values generated in developed countries could lead to inappropriate diagnosis and treatment of patients. There was also variation of reference interval values based on climate, gender, age, monthly income and geographical locations. Therefore, further study is required to establish reference intervals for Ethiopian population. PMID:28886191
Tohidi, Maryam; Ghasemi, Asghar; Hadaegh, Farzad; Derakhshan, Arash; Chary, Abdolreza; Azizi, Fereidoun
2014-04-01
Increased insulin concentration is a surrogate for insulin resistance and early assessment of fasting insulin may help in identifying those who are potentially at high risk of type 2 diabetes, hypertension, and cardiovascular disease. The aim of this study was to determine age- and sex-related reference values for serum insulin and insulin resistance/sensitivity indices in Iranian subjects. Serum insulin levels were measured by electrochemiluminescence immunoassay in 5786 participants of the Tehran Lipid and Glucose Study. After application of exclusion criteria, 309 non-obese healthy subjects (124 men and 185 women), aged 24-83 y, were included. The International Federation of Clinical Chemistry guidelines (non-parametric method) and the robust method were used for determining reference values. Overall 95% reference values for fasting insulin were 1.61-11.37, 2.34-11.98, and 2.11-12.49 μU/mL in men, women, and total population respectively. Mean fasting insulin concentration showed a decreasing trend with age in both genders (p for trend ≤0.001). Age, waist circumference, and systolic blood pressures were biological determinants of fasting insulin in both genders; in addition, insulin was modulated by triglycerides in men and fasting glucose in women. Reference intervals for HOMA1-IR, HOMA2-IR, and QUICKI were 0.63-2.68, 0.40-1.80, and 0.33-0.42, respectively. This study presents the first set of reference values for fasting serum insulin to be 2-12 μU/mL for both genders in a healthy sample of Iranian adults along with the reference values for insulin resistance/sensitivity indices. These values could be used for identifying subjects with insulin resistance in epidemiological and clinical research. Copyright © 2014 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
Commonly used reference values underestimate oxygen uptake in healthy, 50-year-old Swedish women.
Genberg, M; Andrén, B; Lind, L; Hedenström, H; Malinovschi, A
2018-01-01
Cardiopulmonary exercise testing (CPET) is the gold standard among clinical exercise tests. It combines a conventional stress test with measurement of oxygen uptake (V O 2 ) and CO 2 production. No validated Swedish reference values exist, and reference values in women are generally understudied. Moreover, the importance of achieved respiratory exchange ratio (RER) and the significance of breathing reserve (BR) at peak exercise in healthy individuals are poorly understood. We compared V O 2 at maximal load (peakV O 2 ) and anaerobic threshold (V O 2@ AT ) in healthy Swedish individuals with commonly used reference values, taking gender into account. Further, we analysed maximal workload and peakV O 2 with regard to peak RER and BR. In all, 181 healthy, 50-year-old individuals (91 women) performed CPET. PeakV O 2 was best predicted using Jones et al. (100·5%), while SHIP reference values underestimated peakV O 2 most: 112·5%. Furthermore, underestimation of peakV O 2 in women was found for all studied reference values (P<0·001) and was largest for SHIP: women had 128% of predicted peakV O 2 , while men had 104%. PeakV O 2 was similar in subjects with peak RER of 1-1·1 and RER > 1·1 (2 328·7 versus 2 176·7 ml min -1 , P = 0·11). Lower BR (≤30%) related to significantly higher peakV O 2 (P<0·001). In conclusion, peakV O 2 was best predicted by Jones. All studied reference values underestimated oxygen uptake in women. No evidence for demanding RER > 1·1 in healthy individuals was found. A lowered BR is probably a normal response to higher workloads in healthy individuals. © 2016 Scandinavian Society of Clinical Physiology and Nuclear Medicine. Published by John Wiley & Sons Ltd.
Pool power control in remelting systems
Williamson, Rodney L [Albuquerque, NM; Melgaard, David K [Albuquerque, NM; Beaman, Joseph J [Austin, TX
2011-12-13
An apparatus for and method of controlling a remelting furnace comprising adjusting current supplied to an electrode based upon a predetermined pool power reference value and adjusting the electrode drive speed based upon the predetermined pool power reference value.
Optimal weighted combinatorial forecasting model of QT dispersion of ECGs in Chinese adults.
Wen, Zhang; Miao, Ge; Xinlei, Liu; Minyi, Cen
2016-07-01
This study aims to provide a scientific basis for unifying the reference value standard of QT dispersion of ECGs in Chinese adults. Three predictive models including regression model, principal component model, and artificial neural network model are combined to establish the optimal weighted combination model. The optimal weighted combination model and single model are verified and compared. Optimal weighted combinatorial model can reduce predicting risk of single model and improve the predicting precision. The reference value of geographical distribution of Chinese adults' QT dispersion was precisely made by using kriging methods. When geographical factors of a particular area are obtained, the reference value of QT dispersion of Chinese adults in this area can be estimated by using optimal weighted combinatorial model and reference value of the QT dispersion of Chinese adults anywhere in China can be obtained by using geographical distribution figure as well.
Liu, Xiaobing; Zhang, Yu; Piao, Jianhua; Mao, Deqian; Li, Yajie; Li, Weidong; Yang, Lichen; Yang, Xiaoguang
2017-03-21
The development of reference values of trace elements is recognized as a fundamental prerequisite for the assessment of trace element nutritional status and health risks. In this study, a total of 1400 pregnant women aged 27.0 ± 4.5 years were randomly selected from the China Nutrition and Health Survey 2010-2012 (CNHS 2010-2012). The concentrations of 14 serum trace elements were determined by high-resolution inductively coupled plasma mass spectrometry. Reference values were calculated covering the central 95% reference intervals (P2.5-P97.5) after excluding outliers by Dixon's test. The overall reference values of serum trace elements were 131.5 (55.8-265.0 μg/dL for iron (Fe), 195.5 (107.0-362.4) μg/dL for copper (Cu), 74.0 (51.8-111.3) μg/dL for zinc (Zn), 22.3 (14.0-62.0) μg/dL for rubidium (Rb), 72.2 (39.9-111.6) μg/L for selenium (Se), 45.9 (23.8-104.3) μg/L for strontium (Sr), 1.8 (1.2-3.6) μg/L for molybdenum (Mo), 2.4 (1.2-8.4) μg/L for manganese (Mn), 1.9 (0.6-9.0) ng/L for lead (Pb), 1.1 (0.3-5.6) ng/L for arsenic (As), 835.6 (219.8-4287.7) ng/L for chromium (Cr), 337.9 (57.0-1130.0) ng/L for cobalt (Co), 193.2 (23.6-2323.1) ng/L for vanadium (V), and 133.7 (72.1-595.1) ng/L for cadmium (Cd). Furthermore, some significant differences in serum trace element reference values were observed between different groupings of age intervals, residences, anthropometric status, and duration of pregnancy. We found that serum Fe, Zn, and Se concentrations significantly decreased, whereas serum Cu, Sr, and Co concentrations elevated progressively compared with reference values of 14 serum trace elements in pregnant Chinese women. The reference values of serum trace elements established could play a key role in the following nutritional status and health risk assessment.
Choice by Value Encoding and Value Construction: Processes of Loss Aversion
ERIC Educational Resources Information Center
Willemsen, Martijn C.; Bockenholt, Ulf; Johnson, Eric J.
2011-01-01
Loss aversion and reference dependence are 2 keystones of behavioral theories of choice, but little is known about their underlying cognitive processes. We suggest an additional account for loss aversion that supplements the current account of the value encoding of attributes as gains or losses relative to a reference point, introducing a value…
Karon, Brad S; Wickremasinghe, Andrea C; Lo, Stanley F; Saenger, Amy K; Cook, Walter J
2010-08-01
To determine the relationship between BiliChek TcB (Respironics, Marietta GA) and Doumas reference serum or plasma total bilirubin (TSB). Pooled samples with values assigned by the Doumas reference method were used to establish the relationship between a local laboratory and reference Doumas TSB. We then established the relationship between TcB and TSB in the 3 months before and after reassignment of calibrator setpoints undertaken to match the local laboratory to Doumas reference bilirubin values. Before calibrator setpoint reassignment TSB as measured in our laboratory overestimated Doumas reference bilirubin. After calibrator adjustment laboratory TSB was within 1.7-6.8 micromol/L (0.1-0.4 mg/dL) of Doumas reference values. Mean bias between BiliChek TcB and TSB was 42.8+/-22.2 micromol/L (2.5+/-1.3mg/dL) (n=94) before and 49.6+/-22.2 micromol/L (2.9+/-1.3mg/dL) (n=115) after calibration adjustment. BiliChek TcB significantly overestimates TSB as measured by the Doumas reference method. 2010 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
Thomas, Jeanice B; Duewer, David L; Mugenya, Isaac O; Phinney, Karen W; Sander, Lane C; Sharpless, Katherine E; Sniegoski, Lorna T; Tai, Susan S; Welch, Michael J; Yen, James H
2012-01-01
Standard Reference Material 968e Fat-Soluble Vitamins, Carotenoids, and Cholesterol in Human Serum provides certified values for total retinol, γ- and α-tocopherol, total lutein, total zeaxanthin, total β-cryptoxanthin, total β-carotene, 25-hydroxyvitamin D(3), and cholesterol. Reference and information values are also reported for nine additional compounds including total α-cryptoxanthin, trans- and total lycopene, total α-carotene, trans-β-carotene, and coenzyme Q(10). The certified values for the fat-soluble vitamins and carotenoids in SRM 968e were based on the agreement of results from the means of two liquid chromatographic methods used at the National Institute of Standards and Technology (NIST) and from the median of results of an interlaboratory comparison exercise among institutions that participate in the NIST Micronutrients Measurement Quality Assurance Program. The assigned values for cholesterol and 25-hydroxyvitamin D(3) in the SRM are the means of results obtained using the NIST reference method based upon gas chromatography-isotope dilution mass spectrometry and liquid chromatography-isotope dilution tandem mass spectrometry, respectively. SRM 968e is currently one of two available health-related NIST reference materials with concentration values assigned for selected fat-soluble vitamins, carotenoids, and cholesterol in human serum matrix. This SRM is used extensively by laboratories worldwide primarily to validate methods for determining these analytes in human serum and plasma and for assigning values to in-house control materials. The value assignment of the analytes in this SRM will help support measurement accuracy and traceability for laboratories performing health-related measurements in the clinical and nutritional communities.
Junction Potentials Bias Measurements of Ion Exchange Membrane Permselectivity.
Kingsbury, Ryan S; Flotron, Sophie; Zhu, Shan; Call, Douglas F; Coronell, Orlando
2018-04-17
Ion exchange membranes (IEMs) are versatile materials relevant to a variety of water and waste treatment, energy production, and industrial separation processes. The defining characteristic of IEMs is their ability to selectively allow positive or negative ions to permeate, which is referred to as permselectivity. Measured values of permselectivity that equal unity (corresponding to a perfectly selective membrane) or exceed unity (theoretically impossible) have been reported for cation exchange membranes (CEMs). Such nonphysical results call into question our ability to correctly measure this crucial membrane property. Because weighing errors, temperature, and measurement uncertainty have been shown to not explain these anomalous permselectivity results, we hypothesized that a possible explanation are junction potentials that occur at the tips of reference electrodes. In this work, we tested this hypothesis by comparing permselectivity values obtained from bare Ag/AgCl wire electrodes (which have no junction) to values obtained from single-junction reference electrodes containing two different electrolytes. We show that permselectivity values obtained using reference electrodes with junctions were greater than unity for CEMs. In contrast, electrodes without junctions always produced permselectivities lower than unity. Electrodes with junctions also resulted in artificially low permselectivity values for AEMs compared to electrodes without junctions. Thus, we conclude that junctions in reference electrodes introduce two biases into results in the IEM literature: (i) permselectivity values larger than unity for CEMs and (ii) lower permselectivity values for AEMs compared to those for CEMs. These biases can be avoided by using electrodes without a junction.
Development of saw palmetto (Serenoa repens) fruit and extract standard reference materials.
Schantz, Michele M; Bedner, Mary; Long, Stephen E; Molloy, John L; Murphy, Karen E; Porter, Barbara J; Putzbach, Karsten; Rimmer, Catherine A; Sander, Lane C; Sharpless, Katherine E; Thomas, Jeanice B; Wise, Stephen A; Wood, Laura J; Yen, James H; Yarita, Takashi; NguyenPho, Agnes; Sorenson, Wendy R; Betz, Joseph M
2008-10-01
As part of a collaboration with the National Institutes of Health's Office of Dietary Supplements and the Food and Drug Administration's Center for Drug Evaluation and Research, the National Institute of Standards and Technology has developed two standard reference materials (SRMs) representing different forms of saw palmetto (Serenoa repens), SRM 3250 Serenoa repens fruit and SRM 3251 Serenoa repens extract. Both of these SRMs have been characterized for their fatty acid and phytosterol content. The fatty acid concentration values are based on results from gas chromatography with flame ionization detection (GC-FID) and mass spectrometry (GC/MS) analysis while the sterol concentration values are based on results from GC-FID and liquid chromatography with mass spectrometry analysis. In addition, SRM 3250 has been characterized for lead content, and SRM 3251 has been characterized for the content of beta-carotene and tocopherols. SRM 3250 (fruit) has certified concentration values for three phytosterols, 14 fatty acids as triglycerides, and lead along with reference concentration values for four fatty acids as triglycerides and 16 free fatty acids. SRM 3251 (extract) has certified concentration values for three phytosterols, 17 fatty acids as triglycerides, beta-carotene, and gamma-tocopherol along with reference concentration values for three fatty acids as triglycerides, 17 fatty acids as free fatty acids, beta-carotene isomers, and delta-tocopherol and information values for two phytosterols. These SRMs will complement other reference materials currently available with concentrations for similar analytes and are part of a series of SRMs being developed for dietary supplements.
[Reference values of proteins for the Venezuelan population].
Guerra, Marisa; Hernández, María N; López, Michelle; Alfaro, María J
2013-12-01
This study presents the reference values for protein requirements. The consumption of the Venezuelan population was obtained according to the Food Consumption Monitoring Survey (ESCA) 2010-2012. The diet provided good quality proteins, combining animal and vegetable foods in an approximate ratio of 1:1. The reference values were calculated based on the safe levels of protein intake recommended by WHO/FAO/UN 2007, with an adjustment for protein supply depending on age, weight, and contribution to the caloric formula of proteins for light physical activity. The reference values for protein requirements recommended as safe levels of intake in g/kg/day are 1.14 to 1.80 for males and females less than one-year-old, from 1 to 3 years, 0.90 to 1.14; from 4 to 6 years old, 0.86 to 0.89; and from 7 to 10 years old, 0.91 to 0.92. For adolescents, the average is 0.88 and 1.07 for males and females, respectively. In adults from 20 to 59 years old, 0.83 for men and women is recommended, and for older adults, 1.00 for men and women. In pregnant women, additional consumptions are recommended according to gestation time. Adolescent pregnant women must consume additional 1.2 to 1.7 g/kg/day to normal requirement. In breastfeeding women, the values differ between the first six months postnatal period and after six months of breastfeeding. The reference values for protein in this update were lower than the values of the 2000 version.
Washing the patient: dignity and aesthetic values in nursing care.
Pols, Jeannette
2013-07-01
Dignity is a fundamental concept, but its meaning is not clear. This paper attempts to clarify the term by analysing and reconnecting two meanings of dignity: humanitas and dignitas. Humanitas refers to citizen values that protect individuals as equal to one another. Dignitas refers to aesthetic values embedded in genres of sociality that relate to differences between people. The paper explores these values by way of an empirical ethical analysis of practices of washing psychiatric patients in nursing care. Nurses legitimate the washing of reluctant patients with reference to dignity. The analysis shows the intertwinement of humanitas and dignitas that gives dignity its fundamental meaning. © 2013 John Wiley & Sons Ltd.
The Value Estimation of an HFGW Frequency Time Standard for Telecommunications Network Optimization
NASA Astrophysics Data System (ADS)
Harper, Colby; Stephenson, Gary
2007-01-01
The emerging technology of gravitational wave control is used to augment a communication system using a development roadmap suggested in Stephenson (2003) for applications emphasized in Baker (2005). In the present paper consideration is given to the value of a High Frequency Gravitational Wave (HFGW) channel purely as providing a method of frequency and time reference distribution for use within conventional Radio Frequency (RF) telecommunications networks. Specifically, the native value of conventional telecommunications networks may be optimized by using an unperturbed frequency time standard (FTS) to (1) improve terminal navigation and Doppler estimation performance via improved time difference of arrival (TDOA) from a universal time reference, and (2) improve acquisition speed, coding efficiency, and dynamic bandwidth efficiency through the use of a universal frequency reference. A model utilizing a discounted cash flow technique provides an estimation of the additional value using HFGW FTS technology could bring to a mixed technology HFGW/RF network. By applying a simple net present value analysis with supporting reference valuations to such a network, it is demonstrated that an HFGW FTS could create a sizable improvement within an otherwise conventional RF telecommunications network. Our conservative model establishes a low-side value estimate of approximately 50B USD Net Present Value for an HFGW FTS service, with reasonable potential high-side values to significant multiples of this low-side value floor.
Lorenz, Jennifer M; Tarbox, Lauren; Buck, Bryan; Qi, Haiping; Coplen, Tyler B
2014-10-15
As a result of the scarcity of isotopic reference waters for daily use, a new secondary isotopic reference material for international distribution has been prepared from drinking water collected from the Biscayne aquifer in Ft. Lauderdale, Florida. This isotopic reference water was filtered, homogenized, loaded into glass ampoules, sealed with a torch, autoclaved to eliminate biological activity, and measured by dual-inlet isotope-ratio mass spectrometry. This reference material is available by the case of 144 glass ampoules containing either 4 mL or 5 mL of water in each ampoule. The δ(2)H and δ(18)O values of this reference material are -10.3 ± 0.4‰ and -2.238 ± 0.011‰, respectively, relative to VSMOW, on scales normalized such that the δ(2)H and δ(18)O values of SLAP reference water are, respectively, -428 and -55.5‰. Each uncertainty is an estimated expanded uncertainty (U = 2uc ) about the reference value that provides an interval that has about a 95% probability of encompassing the true value. This isotopic reference material, designated as USGS45, is intended as one of two isotopic reference waters for daily normalization of stable hydrogen and oxygen isotopic analysis of water with an isotope-ratio mass spectrometer or a laser absorption spectrometer. Published in 2014. This article is a U.S. Government work and is in the public domain in the USA. Published in 2014. This article is a U.S. Government work and is in the public domain in the USA.
Creatine and guanidinoacetate reference values in a French population.
Joncquel-Chevalier Curt, Marie; Cheillan, David; Briand, Gilbert; Salomons, Gajja S; Mention-Mulliez, Karine; Dobbelaere, Dries; Cuisset, Jean-Marie; Lion-François, Laurence; Des Portes, Vincent; Chabli, Allel; Valayannopoulos, Vassili; Benoist, Jean-François; Pinard, Jean-Marc; Simard, Gilles; Douay, Olivier; Deiva, Kumaran; Tardieu, Marc; Afenjar, Alexandra; Héron, Delphine; Rivier, François; Chabrol, Brigitte; Prieur, Fabienne; Cartault, François; Pitelet, Gaëlle; Goldenberg, Alice; Bekri, Soumeya; Gerard, Marion; Delorme, Richard; Porchet, Nicole; Vianey-Saban, Christine; Vamecq, Joseph
2013-11-01
Creatine and guanidinoacetate are biomarkers of creatine metabolism. Their assays in body fluids may be used for detecting patients with primary creatine deficiency disorders (PCDD), a class of inherited diseases. Their laboratory values in blood and urine may vary with age, requiring that reference normal values are given within the age range. Despite the long known role of creatine for muscle physiology, muscle signs are not necessarily the major complaint expressed by PCDD patients. These disorders drastically affect brain function inducing, in patients, intellectual disability, autistic behavior and other neurological signs (delays in speech and language, epilepsy, ataxia, dystonia and choreoathetosis), being a common feature the drop in brain creatine content. For this reason, screening of PCDD patients has been repeatedly carried out in populations with neurological signs. This report is aimed at providing reference laboratory values and related age ranges found for a large scale population of patients with neurological signs (more than 6 thousand patients) previously serving as a background population for screening French patients with PCDD. These reference laboratory values and age ranges compare rather favorably with literature values for healthy populations. Some differences are also observed, and female participants are discriminated from male participants as regards to urine but not blood values including creatine on creatinine ratio and guanidinoacetate on creatinine ratio values. Such gender differences were previously observed in healthy populations; they might be explained by literature differential effects of testosterone and estrogen in adolescents and adults, and by estrogen effects in prepubertal age on SLC6A8 function. Finally, though they were acquired on a population with neurological signs, the present data might reasonably serve as reference laboratory values in any future medical study exploring abnormalities of creatine metabolism and transport. © 2013 Elsevier Inc. All rights reserved.
Lorenz, Jennifer M.; Qi, Haiping; Coplen, Tyler B.
2017-01-01
As a result of the scarcity of isotopic reference waters for daily use, a new secondary isotopic reference material for international distribution has been prepared from ice-core water from the Amundsen–Scott South Pole Station. This isotopic reference material, designated as USGS49, was filtered, homogenised, loaded into glass ampoules, sealed with a torch, autoclaved to eliminate biological activity and measured by dual-inlet isotope-ratio mass spectrometry. The δ2H and δ18O values of USGS49 are −394.7 ± 0.4 and −50.55 ± 0.04 mUr (where mUr = 0.001 = ‰), respectively, relative to VSMOW, on scales normalised such that the δ2H and δ18O values of SLAP reference water are, respectively, −428 and −55.5 mUr. Each uncertainty is an estimated expanded uncertainty (U = 2uc) about the reference value that provides an interval that has about a 95% probability of encompassing the true value. This isotopic reference material is intended as one of two isotopic reference waters for daily normalisation of stable hydrogen and oxygen isotopic analysis of water with an isotope-ratio mass spectrometer or a laser absorption spectrometer. It is available by the case of 144 glass ampoules or as a set of sixteen glass ampoules containing 5 ml of water in each ampoule.
On the value of the phenotypes in the genomic era.
Gonzalez-Recio, O; Coffey, M P; Pryce, J E
2014-12-01
Genetic improvement programs around the world rely on the collection of accurate phenotypic data. These phenotypes have an inherent value that can be estimated as the contribution of an additional record to genetic gain. Here, the contribution of phenotypes to genetic gain was calculated using traditional progeny testing (PT) and 2 genomic selection (GS) strategies that, for simplicity, included either males or females in the reference population. A procedure to estimate the theoretical economic contribution of a phenotype to a breeding program is described for both GS and PT breeding programs through the increment in genetic gain per unit of increase in estimated breeding value reliability obtained when an additional phenotypic record is added. The main factors affecting the value of a phenotype were the economic value of the trait, the number of phenotypic records already available for the trait, and its heritability. Furthermore, the value of a phenotype was affected by several other factors, including the cost of establishing the breeding program and the cost of phenotyping and genotyping. The cost of achieving a reliability of 0.60 was assessed for different reference populations for GS. Genomic reference populations of more sires with small progeny group sizes (e.g., 20 equivalent daughters) had a lower cost than those reference populations with either large progeny group sizes for fewer genotyped sires, or female reference populations, unless the heritability was large and the cost of phenotyping exceeded a few hundred dollars; then, female reference populations were preferable from an economic perspective. Copyright © 2014 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Krops, Leonie A; Jaarsma, Eva A; Dijkstra, Pieter U; Geertzen, Jan H B; Dekker, Rienk
2017-01-01
To establish reference values for Health Related Quality of Life (HRQoL) in a Dutch rehabilitation population, and to study effects of patient characteristics, diagnosis and physical activity on HRQoL in this population. Former rehabilitation patients (3169) were asked to fill in a questionnaire including the Dutch version of the RAND-36. Differences between our rehabilitation patients and Dutch reference values were analyzed (t-tests). Effects of patient characteristics, diagnosis and movement intensity on scores on the subscales of the RAND-36 were analyzed using block wise multiple regression analyses. In total 1223 patients (39%) returned the questionnaire. HRQoL was significantly poorer in the rehabilitation patients compared to Dutch reference values on all subscales (p<0.001) except for health change (p = 0.197). Longer time between questionnaire and last treatment was associated with a smaller health change (p = 0.035). Higher age negatively affected physical functioning (p<0.001), social functioning (p = 0.004) and health change (p = 0.001). Diagnosis affected outcomes on all subscales except role limitations physical, and mental health (p ranged <0.001 to 0.643). Higher movement intensity was associated with better outcomes on all subscales except for mental health (p ranged <0.001 to 0.190). HRQoL is poorer in rehabilitation patients compared to Dutch reference values. Physical components of HRQoL are affected by diagnosis. In rehabilitation patients an association between movement intensity and HRQoL was found. For clinical purposes, results of this study can be used as reference values for HRQoL in a rehabilitation setting.
Techniques for Developing Child Dummy Protection Reference Values. Event Report
DOT National Transportation Integrated Search
1996-10-01
The purpose of this report is to present background information and techniques : for developing protection reference values (PRV) to use with child dummies in : out-of-position (OOP) child/air bag interaction testing. Biomechanics experts : agree tha...
[The Study of Health in Pomerania (SHIP) reference values for cardiopulmonary exercise testing].
Gläser, S; Ittermann, T; Schäper, C; Obst, A; Dörr, M; Spielhagen, T; Felix, S B; Völzke, H; Bollmann, T; Opitz, C F; Warnke, C; Koch, B; Ewert, R
2013-01-01
The interpretation of gas exchange measured by cardiopulmonary exercise testing (CPET) depends on reliable reference values. Within the population based Study of Health in Pomerania (SHIP) CPET was assessed in 1706 volunteers. The assessment based on symptom limited exercise tests on a bicycle in a sitting position according to a modified Jones protocol. CPET was embedded in an extensive examination program. After the exclusion of active smokers and volunteers with evidence of cardiopulmonary and musculoskeletal disorders the reference population comprised 616 healthy subjects (333 women) aged 25 to 85 years. Reference equations including upper and/or lower limits based on quantile regression were assessed. All values were corrected for the most important influencing factors.This study provides reference equations for gas exchange and exercise capacity assessed within a population in Germany. © Georg Thieme Verlag KG Stuttgart · New York.
Chiu, C H; Turle, R; Poole, G; Thibert, B; Brubaker, W W; Schantz, M M; Wise, S A
2001-02-01
Due to the limited number of environmental matrix certified reference materials (CRMs) with assigned values for natural levels of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs), an interlaboratory study was undertaken by the National Institute of Standards and Technology (NIST) and Environment Canada to establish reference concentration values for selected PCDD/Fs in two well-characterized NIST Standard Reference Materials (SRMs): SRM 1649a (Urban Dust) and SRM 1944 (New York/New Jersey Waterway Sediment). Results from 14 laboratories were used to provide reference values for the seventeen 2, 3, 7, 8-substituted PCDD/F congeners, the totals for individual tetra- through hepta-substituted PCDD/F homologues, and the total amount of tetra- through hepta-substituted PCDD/Fs. The mass fractions for the individual 2, 3, 7, 8-substituted congeners range from approximately 0.01 microg/kg to 7 microg/kg dry mass.
Determination of the air w-value in proton beams using ionization chambers with gas flow capability.
Moyers, M F; Vatnitsky, S M; Miller, D W; Slater, J M
2000-10-01
The purpose of this work was to determine the w-value of air for protons using the paired gas method. Several plastic- and magnesium-walled chambers were used with air, synthetic air, nitrogen, and argon flowing gases. Using argon as a reference gas, the w-value of air was measured and ranged from 32.7 to 34.5 J/C for protons with energies encountered in radiotherapy. Using nitrogen as a reference gas, the w-value of air ranged from 35.2 to 35.4 J/C over the same range of proton energies. The w-value was found, at a given energy, to be independent of the ion chamber used. The uncertainty in these measurements was estimated at 5.2% at the 2sigma level. This uncertainty was dominated by the 4.4% uncertainty in the w-value of the reference gas.
Establishment of new complete blood count reference values for healthy Thai adults.
Wongkrajang, P; Chinswangwatanakul, W; Mokkhamakkun, C; Chuangsuwanich, N; Wesarachkitti, B; Thaowto, B; Laiwejpithaya, S; Komkhum, O
2018-04-28
Laboratory reference ranges are essential for diagnostic orientation and treatment decision. As complete blood count parameters are influenced by various factors, including gender, geographic origin, and ethnic origin, it is important to establish specific hematologic reference values for specific populations. This study was conducted at the Department of Clinical Pathology, Faculty of Medicine Siriraj Hospital, Mahidol University, Bangkok, Thailand. Blood samples were taken from healthy adults aged 18-60 years that attended a health check-up program at our hospital during February 2015 to July 2015. Hematologic and routine chemistry analysis were performed. Participants were determined to be healthy based on medical history and routine medical examinations. Serum vitamin B12, folate, ferritin, and hemoglobin typing were also analyzed to exclude the possible presence of anemia. A statistically significant difference was observed between males and females for Hb level, hematocrit level, red blood cell count, mean corpuscular hemoglobin concentration, percentage neutrophils, monocytes and eosinophils, and absolute neutrophil, lymphocyte, basophil, and platelet counts. Accordingly, gender-specific reference intervals were established for all complete blood count parameters in healthy Thai adult population. The reference value ranges established in this study reflect significant differences between genders. It is possible that these reference ranges may be generalizable to adults living in Thailand. The findings of this study emphasize the importance of establishing specific hematologic reference values for specific populations. © 2018 John Wiley & Sons Ltd.
Clark, Samuel A; Hickey, John M; Daetwyler, Hans D; van der Werf, Julius H J
2012-02-09
The theory of genomic selection is based on the prediction of the effects of genetic markers in linkage disequilibrium with quantitative trait loci. However, genomic selection also relies on relationships between individuals to accurately predict genetic value. This study aimed to examine the importance of information on relatives versus that of unrelated or more distantly related individuals on the estimation of genomic breeding values. Simulated and real data were used to examine the effects of various degrees of relationship on the accuracy of genomic selection. Genomic Best Linear Unbiased Prediction (gBLUP) was compared to two pedigree based BLUP methods, one with a shallow one generation pedigree and the other with a deep ten generation pedigree. The accuracy of estimated breeding values for different groups of selection candidates that had varying degrees of relationships to a reference data set of 1750 animals was investigated. The gBLUP method predicted breeding values more accurately than BLUP. The most accurate breeding values were estimated using gBLUP for closely related animals. Similarly, the pedigree based BLUP methods were also accurate for closely related animals, however when the pedigree based BLUP methods were used to predict unrelated animals, the accuracy was close to zero. In contrast, gBLUP breeding values, for animals that had no pedigree relationship with animals in the reference data set, allowed substantial accuracy. An animal's relationship to the reference data set is an important factor for the accuracy of genomic predictions. Animals that share a close relationship to the reference data set had the highest accuracy from genomic predictions. However a baseline accuracy that is driven by the reference data set size and the overall population effective population size enables gBLUP to estimate a breeding value for unrelated animals within a population (breed), using information previously ignored by pedigree based BLUP methods.
Techniques for developing child dummy protection reference values : event report
DOT National Transportation Integrated Search
1996-10-01
The purpose of this report is to present background information and techniques for developing protection reference values (PRV) to use with child dummies in out-of-position (OOP) child/air bag interaction testing. This report summarizes the literatur...
Interlaboratory comparison of reference materials for nitrogen-isotope-ratio measurements
Böhlke, John Karl; Coplen, Tyler B.
1995-01-01
Aliquots of seven different reference materials were distributed for an interlaboratory comparison of stable nitrogen-isotope-ratio measurements. Results from 15 laboratories were compiled and evaluated selectively to yield provisional values of 515N for each material, i, with respect to atmospheric N2 (o1SN,7air). The 515N values reported by the different laboratories are correlated in such a way that some of the major discrepancies may be removed by normalization (/. e., by altering the length of the ô N scale for each laboratory by an amount defined by local measurements of reference materials with extreme values).
Wang, Hui; Wang, Yiping; Zhou, Zhenwei; Wang, Shuo; Yin, Hongyin; Xie, Keqin
2015-06-01
To determine the normal reference value of pyrrole adducts in urine in young people in a university in Shandong, China, and to provide a reliable basis for the clinical diagnosis of n-hexane poisoning. A total of 240 college students were randomly selected. After excluding 32 ineligible students, 208 subjects were included in this study, consisting of 104 males and 104 females, with a mean age of 21?3 years (range: 18 to 24 years). Morning urine was collected from each subject. The content of pyrrole adducts was determined by chromatometry. The content of pyrrole adducts in both male and female obeyed a positively skewed distribution. The median level of pyrrole adducts in male subjects was 0.88 nmol/ml, and the reference value was 0.14-3.92 nmol/ml. The median level of pyrrole adducts in female subjects was 0.93 nmol/ ml, and the reference value was 0.09-3.27 nmol/ml. Student's t test identified no statistical difference in pyrrole adduct level between male and female subjects (t=0.15, P>0.05). The median level of pyrrole adducts in normal young people is 0.91 nmol/ml, and the reference value is 0.11-3.95 nmol/ml.
Children's Perceived Competence Scale: Reference values in Japan.
Nagai, Yukiyo; Nomura, Kayo; Nagata, Masako; Ohgi, Shohei; Iwasa, Mitsuji
2015-12-01
To support children with chronic diseases, reference values to measure developmental changes in self-perception and self-esteem are considered a useful yardstick. To develop reference values to measure self-perceived competence and self-esteem in Japanese children, the Children's Perceived Competence Scale (CPCS) was administered to 768 children of elementary school grade 1 (6 years) to grade 6 (11 years) at four public schools in Japan, from November to December 2012. After excluding 74 with chronic diseases and/or incomplete responses, 694 children were included. CPCS measures children's self-perceived competence in cognitive, social, physical domains, and general self-worth, namely self-esteem. There was a tendency for scores of cognitive and general self-worth to decrease with increasing grade. Scores among grade 5 respondents were significantly lower than those among grade 4 respondents for both social and physical domains. Scores among boys and girls differed significantly, with boys scoring higher for physical domain in grades 3 and 6 and for general self-worth domain in grade 6. The CPCS reference values to measure self-perceived competence and self-esteem in Japanese children were developed in this study. These reference values are useful to inform practitioners supporting children with psychological or psychiatric problems or those with chronic diseases. © The Author(s) 2014.
Noszczyk-Nowak, Agnieszka; Cepiel, Alicja; Janiszewski, Adrian; Pasławski, Robert; Gajek, Jacek; Pasławska, Urszula; Nicpoń, Józef
2016-01-01
Swine are a well-recognized animal model for human cardiovascular diseases. Despite the widespread use of porcine model in experimental electrophysiology, still no reference values for intracardiac electrical activity and conduction parameters determined during an invasive electrophysiology study (EPS) have been developed in this species thus far. The aim of the study was to develop a set of normal values for intracardiac electrical activity and conduction parameters determined during an invasive EPS of swine. The study included 36 healthy domestic swine (24-40 kg body weight). EPS was performed under a general anesthesia with midazolam, propofol and isoflurane. The reference values for intracardiac electrical activity and conduction parameters were calculated as arithmetic means ± 2 standard deviations. The reference values were determined for AH, HV and PA intervals, interatrial conduction time at its own and imposed rhythm, sinus node recovery time (SNRT), corrected sinus node recovery time (CSNRT), anterograde and retrograde Wenckebach points, atrial, atrioventricular node and ventricular refractory periods. No significant correlations were found between body weight and heart rate of the examined pigs and their electrophysiological parameters. The hereby presented reference values can be helpful in comparing the results of various studies, as well as in more accurately estimating the values of electrophysiological parameters that can be expected in a given experiment.
Reference value of impulse oscillometry in taiwanese preschool children.
Lai, Shen-Hao; Yao, Tsung-Chieh; Liao, Sui-Ling; Tsai, Ming-Han; Hua, Men-Chin; Yeh, Kuo-Wei; Huang, Jing-Long
2015-06-01
Impulse oscillometry is a potential technique for assessing the respiratory mechanism-which includes airway resistance and reactance during tidal breathing-in minimally cooperative young children. The reference values available in Asian preschool children are limited, especially in children of Chinese ethnicity. This study aimed to develop reference equations for lung function measurements using impulse oscillometry in Taiwanese children for future clinical application and research exploitation. Impulse oscillometry was performed in 150 healthy Taiwanese children (aged 2-6 years) to measure airway resistance and reactance at various frequencies. We used regression analysis to generate predictive equations separately by age, body height, body weight, and gender. The stepwise regression model revealed that body height was the most significant determinant of airway resistance and reactance in preschool young children. With the growth in height, a decrease in airway resistance and a paradoxical increase in reactance occurred at different frequencies. The regression curve of resistance at 5 Hz was comparable to previous reference values. This study provided reference values for several variables of the impulse oscillometry measurements in healthy Taiwanese children aged 2-6 years. With these reference data, clinical application of impulse oscillometry would be expedient in diagnosing respiratory diseases in preschool children. Copyright © 2014. Published by Elsevier B.V.
Kokubun, Norito; Sonoo, Masahiro; Imai, Tomihiro; Arimura, Yumiko; Kuwabara, Satoshi; Komori, Tetsuo; Kobayashi, Masahito; Nagashima, Takahide; Hatanaka, Yuki; Tsuda, Emiko; Misawa, Sonoko; Abe, Tatsuya; Arimura, Kimiyoshi
2012-03-01
The aim of this study is to establish reference values for single-fibre electromyography (SFEMG) using concentric needles in a prospective, multicentre study. Voluntary or stimulated SFEMG at the extensor digitorum communis (EDC) or frontalis (FRO) muscles was conducted in 56-63 of a total of 69 normal subjects below the age of 60years at six Japanese institutes. The cut-off values for mean consecutive difference (MCD) of individual potentials were calculated using +2.5 SD or 95% prediction limit (one-tail) of the upper 10th percentile MCD value for individual subjects. The cut-off values for individual MCD (+2.5 SD) were 56.8μs for EDC-V (voluntary SFEMG for EDC), 58.8μs for EDC-S (stimulated SFEMG for EDC), 56.8μs for FRO-V (voluntary SFEMG for FRO) and 51.0μs for FRO-S (stimulated SFEMG for FRO). The false positive rates using these cut-off values were around 2%. The +2.5 SD and 95% prediction limit might be two optimal cut-off values, depending on the clinical question. The obtained reference values were larger than those reported previously using concentric needles, but might better coincide with conventional values. This is the first multicentre study reporting reference values for SFEMG using concentric needles. The way to determine cut-off values and the statistically correct definition of the percentile were discussed. Copyright © 2011 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.
Stability of BUN and creatinine determinations on the Siemens Advia 1800 analyzer.
Qin, Jia; Wang, Huiying; Rets, Anton; Harari, Saul; Alexis, Herol; Eid, Ikram; Pincus, Matthew R
2013-11-01
Serum creatinine values of patients tend to change as a result of the use of different blanks used for creatinine determinations on the Advia 1650. After upgrading the analyzer to the Advia 1800, creatinine values tended to be more reproducible. As part of a quality assurance investigation to test the reproducibilities of creatinine values, we determined serial creatinine values in the sera of 13 patients whose initial values were either in the reference range or elevated (range 0.58-7.8 mg/dl). These values were determined concurrently with serum blood urea nitrogen (BUN) determinations (range 6.0-84.4 mg/dl) as these two analytes are used together in evaluation of renal function. We determined BUN and creatinine values, using the glutamate dehydrogenase lined enzyme assay system and the Jaffe method, respectively. We find that all values for creatinine on samples stored at 4 °C were reproducible as were the corresponding BUN values, which is revealed by low values for the coefficients of variation (CVs), that is, mean CV of 4.55% for creatinine and 2.52% for BUN. One sample with relatively high CV (10.6%) for creatinine was found to have an initial value of 1.1 mg/dl, in the reference range; but, on repeat determinations, the obtained levels were as high as 1.5 mg/dl, above the reference range. BUN values for this sample remained in the reference range, suggesting that no renal disease was present. We conclude that creatinine and BUN determinations are stable, but occasional spurious creatinine values can occur on the Advia 1800 analyzer. © 2013 Wiley Periodicals, Inc.
Blood plasma chemistries from wild mourning doves held in captivity.
Schulz, J H; Bermudez, A J; Tomlinson, J L; Firman, J D; He, Z
2000-07-01
Despite the extensive amount of research conducted on mourning doves (Zenaida macroura), no biochemical reference values exist for this species. Our objective, therefore, was to establish base line clinical chemistry reference values for mourning doves to assist with establishing clinical diagnoses. Wild mourning doves were captured 19 March 1996 to 8 August 1996, and 6 February 1998 to 12 May 1998; blood samples were collected from 382 mourning doves. Plasma biochemical values were established for glucose, sodium, potassium, chloride, enzymatic CO2, albumin, total protein, globulin, calcium, phosphorus, cholesterol, magnesium, aspartate aminotransferase (AST), gamma glutamyl transferase (GGT), lactate dehydrogenase (LDH), and uric acid. These reference values are invaluable for determining diagnosis of diseases of the gastrointestinal, hepatic, renal, cardiovascular, musculoskeletal, and endocrine systems.
Kneebone, Jared L.; Daifuku, Stephanie L.; Kehl, Jeffrey A.; ...
2017-07-06
While non-precious metal M-N-C (M = Fe or Co) catalysts have been developed that are effective for the oxygen reduction reaction in polymer electrolyte fuel cells, no consensus has yet been reached regarding the nature of the M sites in these heterogeneous catalysts that are responsible for reaction with dioxygen (O 2). While multiple studies have developed correlations between Fe distributions in as-prepared catalysts and ORR activity, the direct identification of sites reactive towards O 2 or O 2-analog molecules remains a significant challenge. In the present study, we demonstrate a new approach to identifying and characterizing potential Fe activemore » sites in complex ORR catalysts that combines an effective probe molecule (NO (g)) Mössbauer spectroscopy and nuclear resonance vibrational spectroscopy (NRVS) with density functional theory (DFT) calculations. Mössbauer spectroscopic studies demonstrate that NO (g) treatment of electrochemically reduced PANI-57Fe-C leads to selective reaction with only a sub-set of the Fe species present. Nuclear resonance vibrational spectroscopic studies identified new Fe-ligand vibrations associated with the site reactive towards NO (g). DFT calculations of vibrational properties of a small selection of previously proposed active site structures suggest that graphene zig-zag edge hosted Fe-N structures may be responsible for the observed vibrational behavior with NO (g) probe molecules. Moreover, such sites are likely also reactive to O 2, possibly serving as the ORR active sites in the synthesized materials.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kneebone, Jared L.; Daifuku, Stephanie L.; Kehl, Jeffrey A.
While non-precious metal M-N-C (M = Fe or Co) catalysts have been developed that are effective for the oxygen reduction reaction in polymer electrolyte fuel cells, no consensus has yet been reached regarding the nature of the M sites in these heterogeneous catalysts that are responsible for reaction with dioxygen (O 2). While multiple studies have developed correlations between Fe distributions in as-prepared catalysts and ORR activity, the direct identification of sites reactive towards O 2 or O 2-analog molecules remains a significant challenge. In the present study, we demonstrate a new approach to identifying and characterizing potential Fe activemore » sites in complex ORR catalysts that combines an effective probe molecule (NO (g)) Mössbauer spectroscopy and nuclear resonance vibrational spectroscopy (NRVS) with density functional theory (DFT) calculations. Mössbauer spectroscopic studies demonstrate that NO (g) treatment of electrochemically reduced PANI-57Fe-C leads to selective reaction with only a sub-set of the Fe species present. Nuclear resonance vibrational spectroscopic studies identified new Fe-ligand vibrations associated with the site reactive towards NO (g). DFT calculations of vibrational properties of a small selection of previously proposed active site structures suggest that graphene zig-zag edge hosted Fe-N structures may be responsible for the observed vibrational behavior with NO (g) probe molecules. Moreover, such sites are likely also reactive to O 2, possibly serving as the ORR active sites in the synthesized materials.« less
Promotional Perspectives of Reference Group Influence: Advertising Implications
ERIC Educational Resources Information Center
Lessig, V. Parker; Park, C. Whan
1978-01-01
Examines the role of reference groups and promotional appeals in satisfying consumer motivations. Emphasizes three motivational reference group functions: informational, utilitarian, and value-expressive. (RL)
Reference Values for Weight, Height, Head Circumference, and Body Mass Index in Turkish Children.
Neyzi, Olcay; Bundak, Rüveyde; Gökçay, Gülbin; Günöz, Hülya; Furman, Andrzej; Darendeliler, Feyza; Baş, Firdevs
2015-12-01
This study aimed to integrate the existing updated reference standards for the growth of Turkish infants and children and to compare these values with World Health Organization (WHO) reference data, data from some European countries, and also with previous local data. Weight, height, and head circumference measurements were obtained on 2,391 boys and 2,102 girls who were regular attenders of a well child clinic and on 1,100 boys and 1,020 girls attending schools in relatively well-off districts in İstanbul. Mean number of measurements per child was 8.2±3.6 in the age group 0-5 years and 5.5±3.3 in the age group 6-18 years. All children were from well-to-do families and all were healthy. All measurements with the exception of measurements at birth, which were based on reported values, were done by trained personnel. The LMS method was used in the analyses and in the construction of the percentile charts. There is an increase in weight for age and body mass index values for age starting in prepubertal ages, indicating an increasing trend for obesity. Compared to WHO reference data, weight and height values in Turkish children were slightly higher in infants and in children younger than 5 years, while they showed similarity to those reported for children from Norway and Belgium. Head circumference values, which were slightly higher than the WHO references in the first 5 years, were comparable to the data on Belgian and Norwegian children in the first 9 years of life. At older ages, Turkish children showed higher values for head circumference. The relatively larger head circumference values were interpreted to reflect a genetic characteristic.
Shafiee, Gita; Ostovar, Afshin; Heshmat, Ramin; Keshtkar, Abbas Ali; Sharifi, Farshad; Shadman, Zhaleh; Nabipour, Iraj; Soltani, Akbar; Larijani, Bagher
2018-01-01
Sacopenia is a common problem in elderly with the adverse outcomes. The objective of this study was to estimate the peak appendicular skeletal muscle mass (ASM) and age of its attainment by sex among the Iranian population. A total of 691 men and women aged 18-94 years participated in this cross-sectional, population-based study in Bushehr, Iran. ASM was measured by dual X-ray absorptiometry. Cutoff points for men and women were established considering two standard deviations (SDs) below the mean values of the skeletal muscle index (SMI) for young reference groups. The relationship between ASM and age was described by the second-degree regression models. Two SDs below the mean SMIs of reference groups were as cutoff values of low muscle mass in Iranian population. The peak ASM values were 21.35 ± 0.12 Kg and 13.68 ± 0.10 Kg, and the age at peak ASM were 26 (24-28) years and 34 (33-35) years for men and women, respectively. Mean and SD of SMI in those ages were 7.01 ± 0.02 Kg/m 2 and 5.44 ± 0.02 Kg/m 2 among men and women, respectively. Calculated cutoff values of low muscle mass among the Iranian population were 7.0 Kg/m 2 and 5.4 Kg/m 2 among men and women, respectively. Iranian reference values of SMI for both genders were similar to Asia Working Group for Sarcopenia recommendation and lower than the United States and European values. Further studies from different nations and the Middle East countries are needed to obtain reference values for populations, enabling the researchers for comparison and also more valid reports on sarcopenia prevalence.
Mn and Btex Reference Value Arrays (Final Reports)
These final reports are a summary of reference value arrays with critical supporting documentation for the chemicals manganese, benzene, toluene, ethylbenzene, and xylene. Each chemical is covered in a separate document, and each is a statement of the status of the available inha...
Tomatis, Laura; Krebs, Andreas; Siegenthaler, Jessica; Murer, Kurt; de Bruin, Eling D
2015-01-01
Health is closely linked to physical activity and fitness. It is therefore important to monitor fitness in children. Although many reports on physical tests have been published, data comparison between studies is an issue. This study reports Swiss first grade norm values of fitness tests and compares these with criterion reference data. A total of 10,565 boys (7.18 ± 0.42 years) and 10,204 girls (7.14 ± 0.41 years) were tested for standing long jump, plate tapping, 20-m shuttle run, lateral jump and 20-m sprint. Average values for six-, seven- and eight-year-olds were analysed and reference curves for age were constructed. Z-values were generated for comparisons with criterion references reported in the literature. Results were better for all disciplines in seven-year-old first grade children compared to six-year-old children (p < 0.01). Eight-year-old children did not perform better compared to seven-year-old children in the sprint run (p = 0.11), standing long jump (p > 0.99) and shuttle run (p = 0.43), whereas they were better in all other disciplines compared to their younger peers. The average performance of boys was better than girls except for tapping at the age of 8 (p = 0.06). Differences in performance due to testing protocol and setting must be considered when test values from a first grade setting are compared to criterion-based benchmarks. In a classroom setting, younger children tended to have better results and older children tended to have worse outcomes when compared to their age group criterion reference values. Norm reference data are valid allowing comparison with other data generated by similar test protocols applied in a classroom setting.
Kubota, K; Kadomura, T; Ohta, K; Koyama, K; Okuda, H; Kobayashi, M; Ishii, C; Fujiwara, Y; Nishiora, T; Ohmae, Y; Ohmae, T; Kitajima, M
2012-04-01
Protein-energy malnutrition is a common disorder in the elderly. Although serum albumin is commonly used as a nutritional marker, data is lacking on serum albumin levels in the elderly. The purpose of this study was to determine whether serum albumin levels decrease with advancing age and to establish reference value and interval of laboratory data for elderly people (75 years and over). Blood samples from 13821 healthy people, 42064 outpatients, and 15959 inpatients were collected during 2008. Blood from 127 of our nutrition support team (NST) patients was also collected during August 2006 and May 2009, and analyzed. Serum albumin, hemoglobin, total cholesterol levels and lymphocyte count were determined. We analyzed the change in each parameter in accordance with age, compared the data for elderly people with younger people, and established new reference values. Clinical outcomes were examined depending on the improved reference values. Albumin was lower in older persons than in younger persons. The estimated reference value and interval were 42 (48-36) g/l in older persons and was much lower in NST patients. Hemoglobin was decreased while cholesterol and lymphocyte count were not changed in older persons: all were markedly decreased in NST patients. Terms of hospital stay were significantly longer and mortality rates were significantly higher in older persons, comparing from above to below using a new reference value of albumin (36 g/l). The serum albumin level decreases with advancing age, but it was maintained to some extent in healthy older people. Serum albumin levels related to the clinical outcome. Hemoglobin and cholesterol levels and lymphocyte count were all lower in NST patients. These measurements may be valuable markers of nutritional status and can help in guiding the need for nutritional support.
Eikendal, Anouk L M; Bots, Michiel L; Haaring, Cees; Saam, Tobias; van der Geest, Rob J; Westenberg, Jos J M; den Ruijter, Hester M; Hoefer, Imo E; Leiner, Tim
2016-01-01
Reference values for morphological and functional parameters of the cardiovascular system in early life are relevant since they may help to identify young adults who fall outside the physiological range of arterial and cardiac ageing. This study provides age and sex specific reference values for aortic wall characteristics, cardiac function parameters and aortic pulse wave velocity (PWV) in a population-based sample of healthy, young adults using magnetic resonance (MR) imaging. In 131 randomly selected healthy, young adults aged between 25 and 35 years (mean age 31.8 years, 63 men) of the general-population based Atherosclerosis-Monitoring-and-Biomarker-measurements-In-The-YOuNg (AMBITYON) study, descending thoracic aortic dimensions and wall thickness, thoracic aortic PWV and cardiac function parameters were measured using a 3.0T MR-system. Age and sex specific reference values were generated using dedicated software. Differences in reference values between two age groups (25-30 and 30-35 years) and both sexes were tested. Aortic diameters and areas were higher in the older age group (all p<0.007). Moreover, aortic dimensions, left ventricular mass, left and right ventricular volumes and cardiac output were lower in women than in men (all p<0.001). For mean and maximum aortic wall thickness, left and right ejection fraction and aortic PWV we did not observe a significant age or sex effect. This study provides age and sex specific reference values for cardiovascular MR parameters in healthy, young Caucasian adults. These may aid in MR guided pre-clinical identification of young adults who fall outside the physiological range of arterial and cardiac ageing.
Imboden, Mary T; Welch, Whitney A; Swartz, Ann M; Montoye, Alexander H K; Finch, Holmes W; Harber, Matthew P; Kaminsky, Leonard A
2017-01-01
Dual energy x-ray absorptiometry (DXA) is an established technique for the measurement of body composition. Reference values for these variables, particularly those related to fat mass, are necessary for interpretation and accurate classification of those at risk for obesity-related health complications and in need of lifestyle modifications (diet, physical activity, etc.). Currently, there are no reference values available for GE-Healthcare DXA systems and it is known that whole-body and regional fat mass measures differ by DXA manufacturer. To develop reference values by age and sex for DXA-derived fat mass measurements with GE-Healthcare systems. A de-identified sample of 3,327 participants (2,076 women, 1,251 men) was obtained from Ball State University's Clinical Exercise Physiology Laboratory and University of Wisconsin-Milwaukee's Physical Activity & Health Research Laboratory. All scans were completed using a GE Lunar Prodigy or iDXA and data reported included percent body fat (%BF), fat mass index (FMI), and ratios of android-to-gynoid (A/G), trunk/limb, and trunk/leg fat measurements. Percentiles were calculated and a factorial ANOVA was used to determine differences in the mean values for each variable between age and sex. Normative reference values for fat mass variables from DXA measurements obtained from GE-Healthcare DXA systems are presented as percentiles for both women and men in 10-year age groups. Women had higher (p<0.01) mean %BF and FMI than men, whereas men had higher (p<0.01) mean ratios of A/G, trunk/limb, and trunk/leg fat measurements than women. These reference values provide clinicians and researchers with a resource for interpretation of DXA-derived fat mass measurements specific to use with GE-Healthcare DXA systems.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kirman, C R.; Sweeney, Lisa M.; Corley, Rick A.
2005-04-01
Reference values, including an oral reference dose (RfD) and an inhalation reference concentration (RfC), were derived for propylene glycol methyl ether (PGME), and an oral RfD was derived for its acetate (PGMEA). These values were based upon transient sedation observed in F344 rats and B6C3F1 mice during a two-year inhalation study. The dose-response relationship for sedation was characterized using internal dose measures as predicted by a physiologically based pharmacokinetic (PBPK) model for PGME and its acetate. PBPK modeling was used to account for changes in rodent physiology and metabolism due to aging and adaptation, based on data collected during weeksmore » 1, 2, 26, 52, and 78 of a chronic inhalation study. The peak concentration of PGME in richly perfused tissues was selected as the most appropriate internal dose measure based upon a consideration of the mode of action for sedation and similarities in tissue partitioning between brain and other richly perfused tissues. Internal doses (peak tissue concentrations of PGME) were designated as either no-observed-adverse-effect levels (NOAELs) or lowest-observed-adverse-effect levels (LOAELs) based upon the presence or absence of sedation at each time-point, species, and sex in the two year study. Distributions of the NOAEL and LOAEL values expressed in terms of internal dose were characterized using an arithmetic mean and standard deviation, with the mean internal NOAEL serving as the basis for the reference values, which was then divided by appropriate uncertainty factors. Where data were permitting, chemical-specific adjustment factors were derived to replace default uncertainty factor values of ten. Nonlinear kinetics are were predicted by the model in all species at PGME concentrations exceeding 100 ppm, which complicates interspecies and low-dose extrapolations. To address this complication, reference values were derived using two approaches which differ with respect to the order in which these extrapolations were performed: (1) uncertainty factor application followed by interspecies extrapolation (PBPK modeling); and (2) interspecies extrapolation followed by uncertainty factor application. The resulting reference values for these two approaches are substantially different, with values from the former approach being 7-fold higher than those from the latter approach. Such a striking difference between the two approaches reveals an underlying issue that has received little attention in the literature regarding the application of uncertainty factors and interspecies extrapolations to compounds where saturable kinetics occur in the range of the NOAEL. Until such discussions have taken place, reference values based on the latter approach are recommended for risk assessments involving human exposures to PGME and PGMEA.« less
Ma, Jun; Wang, Zhiqiang; Song, Yi; Hu, Peijin; Zhang, Bing
2010-12-01
To establish BMI percentile curves that describe the contemporary BMI distribution among Chinese children, and to compare their BMI percentile curves with those in two recently developed international references: the WHO and the US Centers for Disease Control and Prevention (US CDC) growth references. A cross-sectional national survey. Thirty provinces, municipalities and autonomous regions in China. Nationally representative sample of 232 140 school students aged 7-18 years. BMI percentile curves were established using the LMS method, and were compared with the percentiles of the WHO and the US CDC references. BMI distributions and growth patterns in Chinese children were dramatically different from those in the two international reference populations. Compared with the international reference populations, younger Chinese boys (7-12 years of age) had higher values of the percentiles above the median and lower values of the percentiles below the median, suggesting that they had larger proportions of extreme BMI values in both directions. Chinese girls and older Chinese boys (15-18 years of age) had substantially lower BMI percentiles than their counterparts in the reference populations, particularly those high percentiles among older age groups. The present study described the unique patterns of BMI curves at the national level, and these curves are useful as a reference for comparing different regions and for monitoring changes over time in Chinese children. Higher proportions of children with extreme values in both directions indicate that China is currently facing both an increasing level of obesity and a high level of undernutrition, simultaneously.
Hrubec, Terry C.; Smith, Stephen A.; Robertson, John L.
2001-01-01
Hybrid striped bass (Morone chrysops X Morone saxatilis ) are an important aquaculture species yet there are few diagnostic tools available to assess their health. Hematology and clinical chemistry analyses are not used extensively in fish medicine due to the lack of reference intervals for various fish species, and because factors such as age can affect blood values. There is little published information regarding age-related changes in blood values of juvenile fish. It is important to evaluate juvenile fish, as this is the time they are raised in aquaculture settings. Determining age-related changes in the blood values of fishes would further develop clinical pathology as a diagnostic tool, enhancing both fish medicine and the aquaculture industry. The results of standard hematology and clinical chemistry analysis were evaluated in juvenile hybrid striped bass at 4, 6, 9, 15, and 19 months of age. Values for PCV and RBC indices were significantly lower, and plasma protein concentration was significantly higher in younger fish. Total WBC and lymphocyte counts were significantly higher in fish at 6 and 9 months of age, while neutrophil and monocyte counts were higher at 6, 9, and 15 months. Eosinophil counts were significantly higher in 9-month-old fish. The majority of hematologic values fell within previously established reference intervals, indicating that only slight modification to the intervals is necessary for evaluating hematologic results of hybrid striped bass at different ages. The following analytes deviated sufficiently from adult reference intervals to warrant separate reference values: plasma protein concentration at 4 months, WBC and lymphocyte counts at 15 and 19 months, and thrombocyte-like-cells at 9 months of age. Values for most biochemical analytes were significantly different among age groups except for creatinine and potassium concentrations. Comparisons with reference intervals were not made for biochemical analytes, because established reference intervals were not available. Age-related changes in hematologic and biochemical values of striped bass were similar to those reported for rainbow trout and mammals.
Validating Reference Equations for Impulse Oscillometry in Healthy Mexican Children.
Gochicoa-Rangel, Laura; Del Río-Hidalgo, Rodrigo; Hernández-Ruiz, Juana; Rodríguez-Moreno, Luis; Martínez-Briseño, David; Mora-Romero, Uri; Cid-Juárez, Silvia; García-Sancho, Cecilia; Torre-Bouscoulet, Luis
2017-09-01
The impulse oscillometry system (IOS) measures the impedance (Z) of the respiratory system, but proper interpretation of its results requires adequate reference values. The objectives of this work were: (1) to validate the reference equations for the IOS published previously by our group and (2) to compare the adjustment of new available reference equations for the IOS from different countries in a sample of healthy children. Subjects were healthy 4-15-y-old children from the metropolitan area of Mexico City, who performed an IOS test. The functional IOS parameters obtained were compared with the predicted values from 12 reference equations determined in studies of different ethnic groups. The validation methods applied were: analysis of the differences between measured and predicted values for each reference equation; correlation and concordance coefficients; adjustment by Z-score values; percentage of predicted value; and the percentage of patients below the lower limit of normality or above the upper limit of normality. Of the 224 participants, 117 (52.3%) were girls, and the mean age was 8.6 ± 2.3 y. The equations that showed the best adjustment for the different parameters were those from the studies by Nowowiejska et al (2008) and Gochicoa et al (2015). The equations proposed by Frei et al (2005), Hellinckx et al (1998), Kalhoff et al (2011), Klug and Bisgaard (1998), de Assumpção et al (2016), and Dencker et al (2006) overestimated the airway resistance of the children in our sample, whereas the equation of Amra et al (2008) underestimated it. In the analysis of the lower and upper limits of normality, Gochicoa et al equation was the closest, since 5% of subjects were below or above percentiles 5 and 95, respectively. The study found that, in general, all of the equations showed greater error at the extremes of the age distribution. Because of the robust adjustment of the present study reference equations for the IOS, it can be recommended for both clinical and research purposes in our population. The differential adjustment of other equations underlines the need to obtain local reference values. Copyright © 2017 by Daedalus Enterprises.
Liu, Xiaobing; Zhang, Yu; Piao, Jianhua; Mao, Deqian; Li, Yajie; Li, Weidong; Yang, Lichen; Yang, Xiaoguang
2017-01-01
The development of reference values of trace elements is recognized as a fundamental prerequisite for the assessment of trace element nutritional status and health risks. In this study, a total of 1400 pregnant women aged 27.0 ± 4.5 years were randomly selected from the China Nutrition and Health Survey 2010–2012 (CNHS 2010–2012). The concentrations of 14 serum trace elements were determined by high-resolution inductively coupled plasma mass spectrometry. Reference values were calculated covering the central 95% reference intervals (P2.5–P97.5) after excluding outliers by Dixon’s test. The overall reference values of serum trace elements were 131.5 (55.8-265.0 μg/dL for iron (Fe), 195.5 (107.0–362.4) μg/dL for copper (Cu), 74.0 (51.8–111.3) μg/dL for zinc (Zn), 22.3 (14.0–62.0) μg/dL for rubidium (Rb), 72.2 (39.9–111.6) μg/L for selenium (Se), 45.9 (23.8-104.3) μg/L for strontium (Sr), 1.8 (1.2–3.6) μg/L for molybdenum (Mo), 2.4 (1.2–8.4) μg/L for manganese (Mn), 1.9 (0.6–9.0) ng/L for lead (Pb), 1.1 (0.3-5.6) ng/L for arsenic (As), 835.6 (219.8–4287.7) ng/L for chromium (Cr), 337.9 (57.0–1130.0) ng/L for cobalt (Co), 193.2 (23.6–2323.1) ng/L for vanadium (V), and 133.7 (72.1–595.1) ng/L for cadmium (Cd). Furthermore, some significant differences in serum trace element reference values were observed between different groupings of age intervals, residences, anthropometric status, and duration of pregnancy. We found that serum Fe, Zn, and Se concentrations significantly decreased, whereas serum Cu, Sr, and Co concentrations elevated progressively compared with reference values of 14 serum trace elements in pregnant Chinese women. The reference values of serum trace elements established could play a key role in the following nutritional status and health risk assessment. PMID:28335545
Numbers of Beauty: An Innovative Aesthetic Analysis for Orthognathic Surgery Treatment Planning.
Marianetti, Tito Matteo; Gasparini, Giulio; Midulla, Giulia; Grippaudo, Cristina; Deli, Roberto; Cervelli, Daniele; Pelo, Sandro; Moro, Alessandro
2016-01-01
The aim of this study was to validate a new aesthetic analysis and establish the sagittal position of the maxilla on an ideal group of reference. We want to demonstrate the usefulness of these findings in the treatment planning of patients undergoing orthognathic surgery. We took a reference group of 81 Italian women participating in a national beauty contest in 2011 on which we performed Arnett's soft tissues cephalometric analysis and our new "Vertical Planning Line" analysis. We used the ideal values to elaborate the surgical treatment planning of a second group of 60 consecutive female patients affected by skeletal class III malocclusion. Finally we compared both pre- and postoperative pictures with the reference values of the ideal group. The ideal group of reference does not perfectly fit in Arnett's proposed norms. From the descriptive statistical comparison of the patients' values before and after orthognathic surgery with the reference values we observed how all parameters considered got closer to the ideal population. We consider our "Vertical Planning Line" a useful help for orthodontist and surgeon in the treatment planning of patients with skeletal malocclusions, in combination with the clinical facial examination and the classical cephalometric analysis of bone structures.
Perich, C; Ricós, C; Alvarez, V; Biosca, C; Boned, B; Cava, F; Doménech, M V; Fernández-Calle, P; Fernández-Fernández, P; García-Lario, J V; Minchinela, J; Simón, M; Jansen, R
2014-05-15
Current external quality assurance schemes have been classified into six categories, according to their ability to verify the degree of standardization of the participating measurement procedures. SKML (Netherlands) is a Category 1 EQA scheme (commutable EQA materials with values assigned by reference methods), whereas SEQC (Spain) is a Category 5 scheme (replicate analyses of non-commutable materials with no values assigned by reference methods). The results obtained by a group of Spanish laboratories participating in a pilot study organized by SKML are examined, with the aim of pointing out the improvements over our current scheme that a Category 1 program could provide. Imprecision and bias are calculated for each analyte and laboratory, and compared with quality specifications derived from biological variation. Of the 26 analytes studied, 9 had results comparable with those from reference methods, and 10 analytes did not have comparable results. The remaining 7 analytes measured did not have available reference method values, and in these cases, comparison with the peer group showed comparable results. The reasons for disagreement in the second group can be summarized as: use of non-standard methods (IFCC without exogenous pyridoxal phosphate for AST and ALT, Jaffé kinetic at low-normal creatinine concentrations and with eGFR); non-commutability of the reference material used to assign values to the routine calibrator (calcium, magnesium and sodium); use of reference materials without established commutability instead of reference methods for AST and GGT, and lack of a systematic effort by manufacturers to harmonize results. Results obtained in this work demonstrate the important role of external quality assurance programs using commutable materials with values assigned by reference methods to correctly monitor the standardization of laboratory tests with consequent minimization of risk to patients. Copyright © 2013 Elsevier B.V. All rights reserved.
Reference values for clinical laboratory parameters in young adults in Maputo, Mozambique.
Tembe, Nelson; Joaquim, Orvalho; Alfai, Eunice; Sitoe, Nádia; Viegas, Edna; Macovela, Eulalia; Gonçalves, Emilia; Osman, Nafissa; Andersson, Sören; Jani, Ilesh; Nilsson, Charlotta
2014-01-01
Clinical laboratory reference values from North American and European populations are currently used in most Africans countries due to the absence of locally derived reference ranges, despite previous studies reporting significant differences between populations. Our aim was to define reference ranges for both genders in 18 to 24 year-old Mozambicans in preparation for clinical vaccine trials. A cross-sectional study including 257 volunteers (102 males and 155 females) between 18 and 24 years was performedat a youth clinic in Maputo, Mozambique. All volunteers were clinically healthy and human immunodeficiency virus, Hepatitis B virus and syphilis negative.Median and 95% reference ranges were calculated for immunological, hematological and chemistry parameters. Ranges were compared with those reported based on populations in other African countries and the US. The impact of applying US NIH Division of AIDS (DAIDS) toxicity tables was assessed. The immunology ranges were comparable to those reported for the US and western Kenya.There were significant gender differences in CD4+ T cell values 713 cells/µL in males versus 824 cells/µL in females (p<0.0001). Hematologic values differed from the US values but were similar to reports of populations in western Kenya and Uganda. The lower and upper limits of the ranges for hemoglobin, hematocrit, red blood cells, white blood cells and lymphocytes were somewhat lower than those from these African countries. The chemistry values were comparable to US values, with few exceptions. The upper limits for ALT, AST, bilirubin, cholesterol and triglycerides were higher than those from the US. DAIDStables for adverse events predicted 297 adverse events and 159 (62%) of the volunteers would have been excluded. This study is the first to determine normal laboratory parameters in Mozambique. Our results underscore the necessity of establishing region-specific clinical reference ranges for proper patient management and safe conduct of clinical trials.
A new thorium-229 reference material
Essex, Richard M.; Mann, Jaqueline L.; Williams, Ross W.; ...
2017-07-27
A new reference material was characterized for 229Th molality and thorium isotope amount ratios. This reference material is intended for use in nuclear forensic analyses as an isotope dilution mass spectrometry spike. The reference material value and expanded uncertainty (k = 2) for the 229Th molality is (1.1498 ± 0.0016)×10 -10 mol g -1 solution. The value and expanded uncertainty (k = 2) for the n( 230Th)/n( 229Th) ratio is (5.18 ± 0.26)×10 -5 and the n( 232Th)/n( 229Th) ratio is (3.815 ± 0.092)×10 -4.
A new thorium-229 reference material
DOE Office of Scientific and Technical Information (OSTI.GOV)
Essex, Richard M.; Mann, Jaqueline L.; Williams, Ross W.
A new reference material was characterized for 229Th molality and thorium isotope amount ratios. This reference material is intended for use in nuclear forensic analyses as an isotope dilution mass spectrometry spike. The reference material value and expanded uncertainty (k = 2) for the 229Th molality is (1.1498 ± 0.0016)×10 -10 mol g -1 solution. The value and expanded uncertainty (k = 2) for the n( 230Th)/n( 229Th) ratio is (5.18 ± 0.26)×10 -5 and the n( 232Th)/n( 229Th) ratio is (3.815 ± 0.092)×10 -4.
This document provides graphical arrays and tables of key information on the derivation of human inhalation health effect reference values for specific chemicals, allowing comparisons across durations, populations, and intended use. A number of program offices within the Agency, ...
McMichael, Lee; Edson, Daniel; McLaughlin, Amanda; Mayer, David; Kopp, Steven; Meers, Joanne; Field, Hume
2015-01-01
This paper establishes reference ranges for hematologic and plasma biochemistry values in wild Black flying-foxes (Pteropus alecto) captured in South East Queensland, Australia. Values were found to be consistent with those of other Pteropus species. Four hundred and forty-seven animals were sampled over 12 months and significant differences were found between age, sex, reproductive and body condition cohorts in the sample population. Mean values for each cohort fell within the determined normal adult reference range, with the exception of elevated levels of alkaline phosphatase in juvenile animals. Hematologic and biochemistry parameters of injured animals showed little or no deviation from the normal reference values for minor injuries, while two animals with more severe injury or abscessation showed leucocytosis, anaemia, thrombocytosis, hyperglobulinemia and hypoalbuminemia. PMID:25938493
Aircraft system modeling error and control error
NASA Technical Reports Server (NTRS)
Kulkarni, Nilesh V. (Inventor); Kaneshige, John T. (Inventor); Krishnakumar, Kalmanje S. (Inventor); Burken, John J. (Inventor)
2012-01-01
A method for modeling error-driven adaptive control of an aircraft. Normal aircraft plant dynamics is modeled, using an original plant description in which a controller responds to a tracking error e(k) to drive the component to a normal reference value according to an asymptote curve. Where the system senses that (1) at least one aircraft plant component is experiencing an excursion and (2) the return of this component value toward its reference value is not proceeding according to the expected controller characteristics, neural network (NN) modeling of aircraft plant operation may be changed. However, if (1) is satisfied but the error component is returning toward its reference value according to expected controller characteristics, the NN will continue to model operation of the aircraft plant according to an original description.
Method and apparatus for measuring response time
Johanson, Edward W.; August, Charles
1985-01-01
A method of measuring the response time of an electrical instrument which generates an output signal in response to the application of a specified input, wherein the output signal varies as a function of time and when subjected to a step input approaches a steady-state value, comprises the steps of: (a) applying a step input of predetermined value to the electrical instrument to generate an output signal; (b) simultaneously starting a timer; (c) comparing the output signal to a reference signal to generate a stop signal when the output signal is substantially equal to the reference signal, the reference signal being a specified percentage of the steady-state value of the output signal corresponding to the predetermined value of the step input; and (d) applying the stop signal when generated to stop the timer.
Method and apparatus for measuring response time
Johanson, E.W.; August, C.
1983-08-11
A method of measuring the response time of an electrical instrument which generates an output signal in response to the application of a specified input, wherein the output signal varies as a function of time and when subjected to a step input approaches a steady-state value, comprises the steps of: (a) applying a step input of predetermined value to the electrical instrument to generate an output signal; (b) simultaneously starting a timer; (c) comparing the output signal to a reference signal to generate a stop signal when the output signal is substantially equal to the reference signal, the reference signal being a specified percentage of the steady-state value of the output signal corresponding to the predetermined value of the step input; and (d) applying the stop signal when generated to stop the timer.
Macedo Ribeiro, Ana Freire; Bergmann, Anke; Lemos, Thiago; Pacheco, Antônio Guilherme; Mello Russo, Maitê; Santos de Oliveira, Laura Alice; de Carvalho Rodrigues, Erika
The main objective of this study was to review the literature to identify reference values for angles and distances of body segments related to upright posture in healthy adult women with the Postural Assessment Software (PAS/SAPO). Electronic databases (BVS, PubMed, SciELO and Scopus) were assessed using the following descriptors: evaluation, posture, photogrammetry, physical therapy, postural alignment, postural assessment, and physiotherapy. Studies that performed postural evaluation in healthy adult women with PAS/SAPO and were published in English, Portuguese and Spanish, between the years 2005 and 2014 were included. Four studies met the inclusion criteria. Data from the included studies were grouped to establish the statistical descriptors (mean, variance, and standard deviation) of the body angles and distances. A total of 29 variables were assessed (10 in the anterior views, 16 in the lateral right and left views, and 3 in the posterior views), and its respective mean and standard deviation were calculated. Reference values for the anterior and posterior views showed no symmetry between the right and left sides of the body in the frontal plane. There were also small differences in the calculated reference values for the lateral view. The proposed reference values for quantitative evaluation of the upright posture in healthy adult women estimated in the present study using PAS/SAPO could guide future studies and help clinical practice. Copyright © 2017. Published by Elsevier Inc.
Consumer understanding of calorie labeling: a healthy monday e-mail and text message intervention.
Abel, Michelle L; Lee, Katherine; Loglisci, Ralph; Righter, Allison; Hipper, Thomas J; Cheskin, Lawrence J
2015-03-01
To assess caloric knowledge of participants and determine if an e-mail and/or text message intervention could increase knowledge of recommended daily caloric intake. Randomized, control trial. Johns Hopkins Hospital Cobblestone Café. The 246 participants reported eating at the Café at least twice/week. Participants randomized to control, e-mail, or text condition. The text and e-mail conditions received a message on four consecutive Mondays stating the recommended daily caloric intake. Knowledge of the government reference value of 2,000 calories. Intention-to-treat analysis was conducted. Multivariate logistic regression examined the effectiveness of text and e-mail messaging for improving knowledge of the government calorie reference value. Baseline awareness of the daily calorie reference value in study population was low. Participants in the text message condition were twice as likely to know the government calorie reference value compared to controls (p = .047, odds ratio = 2.2, 95% confidence interval [1.01, 4.73]). No significant differences were found for the e-mail condition (p = .5). Many people do not know the daily recommended caloric intake. Public education on the government calorie reference value is necessary for menu-labeling interventions to be more effective. Weekly text messaging can serve as an effective modality for delivering calorie information and nutrition education. © 2014 Society for Public Health Education.
Mederico, Maracelly; Paoli, Mariela; Zerpa, Yajaira; Briceño, Yajaira; Gómez-Pérez, Roald; Martínez, José Luis; Camacho, Nolis; Cichetti, Rosanna; Molina, Zarela; Mora, Yolanda; Valeri, Lenin
2013-05-01
To collect regional reference values of waist circumference (WC), and waist/hip ratio (WHR) in children and adolescents from Merida, Venezuela, and to compare them to international references. A total of 919 students aged 9-17 years from public and private educational establishments were assessed. Weight, height, WC, and WHR were measured. Outliers (± 3 SD Z-Score) were excluded from the data collected. Percentile distribution of the tested variables was done by age and sex. Fifty-one percent of subjects were female, and 52.7% were from public institutions. WC (p=0.001) and WHR (p=0.0001) were statistically higher in boys. With advancing age, WC increased in both sexes, while WHR showed the opposite behavior (p=0.0001 for both). The 90th percentile (pc) for WC ranged from 69.7 and 83.6 cm in girls and from 69.2 and 86.7 cm in boys. The 90th pc values of WHR ranged from 0.79 and 0.91 in girls and from 0.86 and 0.93 in boys. Overall, our WC and WHR values were lower than North American values and similar to those of some Latin American references. Percentile reference charts for WC and WHR specific for age and sex, obtained from a representative sample of children and adolescents from Mérida, Venezuela, are provided. They may be used regionally, both for individual assessment and to implement prevention policies. Copyright © 2012 SEEN. Published by Elsevier Espana. All rights reserved.
Frahm, Jan-Michael; Pollefeys, Marc Andre Leon; Gallup, David Robert
2015-12-08
Methods of generating a three dimensional representation of an object in a reference plane from a depth map including distances from a reference point to pixels in an image of the object taken from a reference point. Weights are assigned to respective voxels in a three dimensional grid along rays extending from the reference point through the pixels in the image based on the distances in the depth map from the reference point to the respective pixels, and a height map including an array of height values in the reference plane is formed based on the assigned weights. An n-layer height map may be constructed by generating a probabilistic occupancy grid for the voxels and forming an n-dimensional height map comprising an array of layer height values in the reference plane based on the probabilistic occupancy grid.
Determination of Age-Dependent Reference Ranges for Coagulation Tests Performed Using Destiny Plus.
Arslan, Fatma Demet; Serdar, Muhittin; Merve Ari, Elif; Onur Oztan, Mustafa; Hikmet Kozcu, Sureyya; Tarhan, Huseyin; Cakmak, Ozgur; Zeytinli, Merve; Yasar Ellidag, Hamit
2016-06-01
In order to apply the right treatment for hemostatic disorders in pediatric patients, laboratory data should be interpreted with age-appropriate reference ranges. The purpose of this study was to determining age-dependent reference range values for prothrombin time (PT), activated partial thromboplastin time (aPTT), fibrinogen tests, and D-dimer tests. A total of 320 volunteers were included in the study with the following ages: 1 month - 1 year (n = 52), 2 - 5 years (n = 50), 6 - 10 years (n = 48), 11 - 17 years (n = 38), and 18 - 65 years (n = 132). Each volunteer completed a survey to exclude hemostatic system disorder. Using a nonparametric method, the lower and upper limits, including 95% distribution and 90% confidence intervals, were calculated. No statistically significant differences were found between PT and aPTT values in the groups consisting of children. Thus, the reference ranges were separated into child and adult age groups. PT and aPTT values were significantly higher in the children than in the adults. Fibrinogen values in the 6 - 10 age group and the adult age group were significantly higher than in the other groups. D-dimer levels were significantly lower in those aged 2 - 17; thus, a separate reference range was established. These results support other findings related to developmental hemostasis, confirming that adult and pediatric age groups should be evaluated using different reference ranges.
Qin, X; Tang, G; Gao, R; Guo, Z; Liu, Z; Yu, S; Chen, M; Tao, Z; Li, S; Liu, M; Wang, L; Hou, L; Xia, L; Cheng, X; Han, J; Qiu, L
2017-08-01
The aim of this study was to investigate the reference interval of protein-induced vitamin K absence or antagonist-II (PIVKA-II) in China population and to evaluate its medical decision level for hepatocellular carcinoma (HCC) diagnosis. To determine the reference range for Chinese individuals, a total of 855 healthy subjects in five typical regions of China were enrolled in this study to obtain a 95% reference interval. In a case-control study which recruited the subjects diagnosed with HCC, metastatic liver cancer, bile duct cancer, hepatitis, cirrhosis, other benign liver diseases and the subjects administrated anticoagulant, receiver operating characteristic analysis was used to determine PIVKA-II cutoff value for a medical decision. The concentration of PIVKA-II had no relationship with age or gender and that region was a significant factor associated with the level of PIVKA-II. The 95% reference interval determined in this study for PIVKA-II in Chinese healthy individuals was 28 mAU/mL, and the cutoff value which to distinguish patients with HCC from disease control groups is 36.5 mAU/mL. In clinical applications, it is recommended that each laboratory chooses their own reference interval based on the regional population study or cutoff value for disease diagnosis. © 2017 John Wiley & Sons Ltd.
NASA Astrophysics Data System (ADS)
Dimbylow, Peter
2005-09-01
Finite-difference time-domain (FDTD) calculations have been performed of the whole-body averaged specific energy absorption rate (SAR) in a female voxel model, NAOMI, under isolated and grounded conditions from 10 MHz to 3 GHz. The 2 mm resolution voxel model, NAOMI, was scaled to a height of 1.63 m and a mass of 60 kg, the dimensions of the ICRP reference adult female. Comparison was made with SAR values from a reference male voxel model, NORMAN. A broad SAR resonance in the NAOMI values was found around 900 MHz and a resulting enhancement, up to 25%, over the values for the male voxel model, NORMAN. This latter result confirmed previously reported higher values in a female model. The effect of differences in anatomy was investigated by comparing values for 10-, 5- and 1-year-old phantoms rescaled to the ICRP reference values of height and mass which are the same for both sexes. The broad resonance in the NAOMI child values around 1 GHz is still a strong feature. A comparison has been made with ICNIRP guidelines. The ICNIRP occupational reference level provides a conservative estimate of the whole-body averaged SAR restriction. The linear scaling of the adult phantom using different factors in longitudinal and transverse directions, in order to match the ICRP stature and weight, does not exactly reproduce the anatomy of children. However, for public exposure the calculations with scaled child models indicate that the ICNIRP reference level may not provide a conservative estimate of the whole-body averaged SAR restriction, above 1.2 GHz for scaled 5- and 1-year-old female models, although any underestimate is by less than 20%.
Dimbylow, Peter
2005-09-07
Finite-difference time-domain (FDTD) calculations have been performed of the whole-body averaged specific energy absorption rate (SAR) in a female voxel model, NAOMI, under isolated and grounded conditions from 10 MHz to 3 GHz. The 2 mm resolution voxel model, NAOMI, was scaled to a height of 1.63 m and a mass of 60 kg, the dimensions of the ICRP reference adult female. Comparison was made with SAR values from a reference male voxel model, NORMAN. A broad SAR resonance in the NAOMI values was found around 900 MHz and a resulting enhancement, up to 25%, over the values for the male voxel model, NORMAN. This latter result confirmed previously reported higher values in a female model. The effect of differences in anatomy was investigated by comparing values for 10-, 5- and 1-year-old phantoms rescaled to the ICRP reference values of height and mass which are the same for both sexes. The broad resonance in the NAOMI child values around 1 GHz is still a strong feature. A comparison has been made with ICNIRP guidelines. The ICNIRP occupational reference level provides a conservative estimate of the whole-body averaged SAR restriction. The linear scaling of the adult phantom using different factors in longitudinal and transverse directions, in order to match the ICRP stature and weight, does not exactly reproduce the anatomy of children. However, for public exposure the calculations with scaled child models indicate that the ICNIRP reference level may not provide a conservative estimate of the whole-body averaged SAR restriction, above 1.2 GHz for scaled 5- and 1-year-old female models, although any underestimate is by less than 20%.
7 CFR 801.12 - Design requirements incorporated by reference.
Code of Federal Regulations, 2010 CFR
2010-01-01
... reference: General Code (1.10.) G-S.5.5. Money Values, Mathematical Agreement G-T.1. Acceptance Tolerances G.... Tolerance Values T.3. For Test Weight Per Bushel Indications or Recorded Representations UR.3.2. Other... Standards and Technology's (NIST) Handbook 44, “Specifications, Tolerances, and Other Technical Requirements...
Reference values for exposure of wildlife to contaminants are needed to cost effectively determine if a site is contaminated and to rank sites that are above background levels. Epidemiological techniques originally developed for clinical chemistry and for determining exposures t...
The Value of Chat Reference Services: A Pilot Study
ERIC Educational Resources Information Center
Jacoby, JoAnn; Ward, David; Avery, Susan; Marcyk, Emilia
2016-01-01
This article explores student, instructor, and librarian perceptions of chat reference in the context of an introductory composition course. Participants in a mixed-method study responded to an anonymized chat transcript. While student respondents valued speed and efficiency, they were willing to receive instruction and open to questions that…
Code of Federal Regulations, 2012 CFR
2012-04-01
... decomposed into an option payout or payouts, is measured by the absolute net value of the put option premia with strike prices less than or equal to the reference price plus the absolute net value of the call... which a commodity-dependent payment becomes non-zero, or, in the case where two potential reference...
Code of Federal Regulations, 2013 CFR
2013-04-01
... decomposed into an option payout or payouts, is measured by the absolute net value of the put option premia with strike prices less than or equal to the reference price plus the absolute net value of the call... which a commodity-dependent payment becomes non-zero, or, in the case where two potential reference...
Code of Federal Regulations, 2011 CFR
2011-04-01
... decomposed into an option payout or payouts, is measured by the absolute net value of the put option premia with strike prices less than or equal to the reference price plus the absolute net value of the call... which a commodity-dependent payment becomes non-zero, or, in the case where two potential reference...
Code of Federal Regulations, 2010 CFR
2010-04-01
... decomposed into an option payout or payouts, is measured by the absolute net value of the put option premia with strike prices less than or equal to the reference price plus the absolute net value of the call... which a commodity-dependent payment becomes non-zero, or, in the case where two potential reference...
Code of Federal Regulations, 2014 CFR
2014-04-01
... decomposed into an option payout or payouts, is measured by the absolute net value of the put option premia with strike prices less than or equal to the reference price plus the absolute net value of the call... which a commodity-dependent payment becomes non-zero, or, in the case where two potential reference...
Estimating the uncertainty in thermochemical calculations for oxygen-hydrogen combustors
NASA Astrophysics Data System (ADS)
Sims, Joseph David
The thermochemistry program CEA2 was combined with the statistical thermodynamics program PAC99 in a Monte Carlo simulation to determine the uncertainty in several CEA2 output variables due to uncertainty in thermodynamic reference values for the reactant and combustion species. In all, six typical performance parameters were examined, along with the required intermediate calculations (five gas properties and eight stoichiometric coefficients), for three hydrogen-oxygen combustors: a main combustor, an oxidizer preburner and a fuel preburner. The three combustors were analyzed in two different modes: design mode, where, for the first time, the uncertainty in thermodynamic reference values---taken from the literature---was considered (inputs to CEA2 were specified and so had no uncertainty); and data reduction mode, where inputs to CEA2 did have uncertainty. The inputs to CEA2 were contrived experimental measurements that were intended to represent the typical combustor testing facility. In design mode, uncertainties in the performance parameters were on the order of 0.1% for the main combustor, on the order of 0.05% for the oxidizer preburner and on the order of 0.01% for the fuel preburner. Thermodynamic reference values for H2O were the dominant sources of uncertainty, as was the assigned enthalpy for liquid oxygen. In data reduction mode, uncertainties in performance parameters increased significantly as a result of the uncertainties in experimental measurements compared to uncertainties in thermodynamic reference values. Main combustor and fuel preburner theoretical performance values had uncertainties of about 0.5%, while the oxidizer preburner had nearly 2%. Associated experimentally-determined performance values for all three combustors were 3% to 4%. The dominant sources of uncertainty in this mode were the propellant flowrates. These results only apply to hydrogen-oxygen combustors and should not be generalized to every propellant combination. Species for a hydrogen-oxygen system are relatively simple, thereby resulting in low thermodynamic reference value uncertainties. Hydrocarbon combustors, solid rocket motors and hybrid rocket motors have combustion gases containing complex molecules that will likely have thermodynamic reference values with large uncertainties. Thus, every chemical system should be analyzed in a similar manner as that shown in this work.
Qi, Haiping; Coplen, Tyler B.; Geilmann, Heike; Brand, Willi A.; Böhlke, J.K.
2003-01-01
Analytical grade L-glutamic acid is chemically stable and has a C/N mole ratio of 5, which is close to that of many of natural biological materials, such as blood and animal tissue. Two L-glutamic acid reference materials with substantially different 13C and 15N abundances have been prepared for use as organic reference materials for C and N isotopic measurements. USGS40 is analytical grade L-glutamic acid and has a δ13C value of −26.24‰ relative to VPDB and a δ15N value of −4.52‰ relative to N2 in air. USGS41 was prepared by dissolving analytical grade L-glutamic acid with L-glutamic acid enriched in 13C and 15N. USGS41 has a δ13C value of +37.76‰ and a δ15N value of +47.57‰. The δ13C and δ15N values of both materials were measured against the international reference materials NBS 19 calcium carbonate (δ13C = +1.95‰), L-SVEC lithium carbonate (δ13C = −46.48‰), IAEA-N-1 ammonium sulfate (δ15N = 0.43‰), and USGS32 potassium nitrate (δ15N = 180‰) by on-line combustion continuous-flow and off-line dual-inlet isotope-ratio mass spectrometry. Both USGS40 and USGS41 are isotopically homogeneous; reproducibility of δ13C is better than 0.13‰, and that of δ15N is better than 0.13‰ in 100-μg amounts. These two isotopic reference materials can be used for (i) calibrating local laboratory reference materials, and (ii) quantifying drift with time, mass-dependent fractionations, and isotope-ratio-scale contraction in the isotopic analysis of various biological materials. Isotopic results presented in this paper yield a δ13C value for NBS 22 oil of −29.91‰, in contrast to the commonly accepted value of −29.78‰ for which off-line blank corrections probably have not been quantified satisfactorily.
[Development of the certified reference material of mercury in lyophilized human urine].
Zhao, Wei; Zhang, Fu-gang; DU, Hui-fang; Pan, Ya-juan; Yan, Hui-fang
2011-02-01
To develop the certified reference material of mercury in lyophilized human urine. Human urine samples from normal level mercury districts were filtered, homogenized, dispensed, lyophilized and radio-sterilized. Homogeneity test, stability inspection and certification were conducted using a atom fluorescence spectrophotometric method. The physical and chemical stability of the certified reference material were assessed for 18 months. The certified values are based on analysis made by three independent laboratories. The certified values are as follows: low level was (35.6 ± 2.1) µg/L, high level was (50.5 ± 3.0) µg/L. The certified reference material of mercury in lyophilized human urine in this research reached the national certified reference material requirements and could be used for the quality control.
Sanada, K; Miyachi, M; Tanimoto, M; Yamamoto, K; Murakami, H; Okumura, S; Gando, Y; Suzuki, K; Tabata, I; Higuchi, M
2010-09-01
In this study of Japanese men and women, we determine reference values for sarcopenia and test the hypothesis that sarcopenia is associated with risk factors for cardiovascular disease, independent of waist circumference. A total of 1,488 Japanese men and women aged 18-85 years participated in this study. Appendicular muscle mass (AMM) was measured by dual-energy X-ray absorptiometry. Reference values for classes 1 and 2 sarcopenia (skeletal muscle index: AMM/height2, kg m-2) in each sex were defined as values one and two standard deviations below the sex-specific means of reference values obtained in this study from young adults aged 18-40 years. The reference values for class 1 and class 2 sarcopenia were 7.77 and 6.87 kg m-2 in men and 6.12 and 5.46 kg m-2 in women. In subjects both with class 1 and class 2 sarcopenia, body mass index and % body fat were significantly lower than in normal subjects. Despite whole-blood glycohaemoglobin A1c in men with class 1 sarcopenia was significantly higher than in normal subjects, and brachial-ankle pulse wave velocity in women both with class 1 and class 2 sarcopenia were significantly higher than in normal subjects, using one-way ANCOVA with adjustment for the covariate of waist circumference. Although sarcopenia is associated with thin body mass, it is associated with more glycation of serum proteins in men and with greater arterial stiffness in women, independent of waist circumference.
Krawczky, Bruna; Pacheco, Antonio G; Mainenti, Míriam R M
2014-05-01
Reference values for postural alignment in the coronal plane, as measured by computerized photogrammetry, have been established but not for the sagittal plane. The objective of this study is to propose reference values for angular measurements used for postural analysis in the sagittal plane for healthy adults. Electronic databases (PubMed, BVS, Cochrane, Scielo, and Science Direct) were searched using the following key words: evaluation, posture, photogrammetry, and software. Articles published between 2006 and 2012 that used the PAS/SAPO (postural assessment software) were selected. Another inclusion criterion was the presentation of, at least, one of the following measurements: head horizontal alignment, pelvic horizontal alignment, hip angle, vertical alignment of the body, thoracic kyphosis, and lumbar lordosis. Angle samples of the selected articles were grouped 2 by 2 in relation to an overall average, which made possible total average, variance, and SD calculations. Six articles were included, and the following average angular values were found: 51.42° ± 4.87° (head horizontal alignment), -12.26° ± 5.81° (pelvic horizontal alignment), -6.40° ± 3.86° (hip angle), and 1.73° ± 0.94° (vertical alignment of the body). None of the articles contained the measurements for thoracic kyphosis and lumbar lordosis. The reference values can be adopted as reference for postural assessment in future researches if the same anatomical points are considered. Copyright © 2014 National University of Health Sciences. Published by Mosby, Inc. All rights reserved.
Ottaway, Josh; Farrell, Jeremy A; Kalivas, John H
2013-02-05
An essential part to calibration is establishing the analyte calibration reference samples. These samples must characterize the sample matrix and measurement conditions (chemical, physical, instrumental, and environmental) of any sample to be predicted. Calibration usually requires measuring spectra for numerous reference samples in addition to determining the corresponding analyte reference values. Both tasks are typically time-consuming and costly. This paper reports on a method named pure component Tikhonov regularization (PCTR) that does not require laboratory prepared or determined reference values. Instead, an analyte pure component spectrum is used in conjunction with nonanalyte spectra for calibration. Nonanalyte spectra can be from different sources including pure component interference samples, blanks, and constant analyte samples. The approach is also applicable to calibration maintenance when the analyte pure component spectrum is measured in one set of conditions and nonanalyte spectra are measured in new conditions. The PCTR method balances the trade-offs between calibration model shrinkage and the degree of orthogonality to the nonanalyte content (model direction) in order to obtain accurate predictions. Using visible and near-infrared (NIR) spectral data sets, the PCTR results are comparable to those obtained using ridge regression (RR) with reference calibration sets. The flexibility of PCTR also allows including reference samples if such samples are available.
Dennen, Kristin O.; Johnson, Craig A.; Otter, Marshall L.; Silva, Steven R.; Wandless, Gregory A.
2006-01-01
Samples of United States Geological Survey (USGS) Certified Reference Materials USGS Devonian Ohio Shale (SDO-1), and USGS Eocene Green River Shale (SGR-1), and National Research Council Canada (NRCC) Certified Marine Sediment Reference Material (PACS-2), were sent for analysis to four separate analytical laboratories as blind controls for organic rich sedimentary rock samples being analyzed from the Red Dog mine area in Alaska. The samples were analyzed for stable isotopes of carbon (delta13Cncc) and nitrogen (delta15N), percent non-carbonate carbon (Wt % Cncc) and percent nitrogen (Wt % N). SDO-1, collected from the Huron Member of the Ohio Shale, near Morehead, Kentucky, and SGR-1, collected from the Mahogany zone of the Green River Formation are petroleum source rocks used as reference materials for chemical analyses of sedimentary rocks. PACS-2 is modern marine sediment collected from the Esquimalt, British Columbia harbor. The results presented in this study are, with the exceptions noted below, the first published for these reference materials. There are published information values for the elemental concentrations of 'organic' carbon (Wt % Corg measured range is 8.98 - 10.4) and nitrogen (Wt % Ntot 0.347 with SD 0.043) only for SDO-1. The suggested values presented here should be considered 'information values' as defined by the NRCC Institute for National Measurement Reference Materials and should be useful for the analysis of 13C, 15N, C and N in organic material in sedimentary rocks.
NASA Astrophysics Data System (ADS)
Wziontek, H.; Palinkas, V.; Falk, R.; Vaľko, M.
2016-12-01
Since decades, absolute gravimeters are compared on a regular basis on an international level, starting at the International Bureau for Weights and Measures (BIPM) in 1981. Usually, these comparisons are based on constant reference values deduced from all accepted measurements acquired during the comparison period. Temporal changes between comparison epochs are usually not considered. Resolution No. 2, adopted by IAG during the IUGG General Assembly in Prague 2015, initiates the establishment of a Global Absolute Gravity Reference System based on key comparisons of absolute gravimeters (AG) under the International Committee for Weights and Measures (CIPM) in order to establish a common level in the microGal range. A stable and unique reference frame can only be achieved, if different AG are taking part in different kind of comparisons. Systematic deviations between the respective comparison reference values can be detected, if the AG can be considered stable over time. The continuous operation of superconducting gravimeters (SG) on selected stations further supports the temporal link of comparison reference values by establishing a reference function over time. By a homogenous reprocessing of different comparison epochs and including AG and SG time series at selected stations, links between several comparisons will be established and temporal comparison reference functions will be derived. By this, comparisons on a regional level can be traced to back to the level of key comparisons, providing a reference for other absolute gravimeters. It will be proved and discussed, how such a concept can be used to support the future absolute gravity reference system.
Mexican-origin youths' trajectories of depressive symptoms: the role of familism values.
Zeiders, Katharine H; Updegraff, Kimberly A; Umaña-Taylor, Adriana J; Wheeler, Lorey A; Perez-Brena, Norma J; Rodríguez, Sue A
2013-11-01
To describe Mexican-origin youths' trajectories of depressive symptoms from early to late adolescence and examine the role of three aspects of familism values: supportive, obligation, and referent. Mexican-origin adolescents (N = 492) participated in home interviews and provided self-reports of depressive symptoms and cultural values at four assessments across an 8-year span. Using a cohort sequential design and accounting for the nesting within the 246 families (two youths per family), we examined depressive symptoms from ages 12 to 22 years and the within-person, between-sibling, and between-family effects of familism values. Mexican-origin males' depressive symptoms decreased across adolescence, whereas females' symptoms exhibited a cubic pattern of change. Results revealed that increases in supportive and referent familism values within individuals and across families were related to lower levels of depressive symptoms. Findings were most pronounced for referent familism values, as a between-sibling effect also emerged. Obligation familism values were not associated with depressive symptoms. Our findings provide important descriptive information about Mexican-origin youths' depressive symptoms and highlight the promotive role of familism values. Copyright © 2013 Society for Adolescent Health and Medicine. Published by Elsevier Inc. All rights reserved.
Korean anatomical reference data for adults for use in radiological protection
NASA Astrophysics Data System (ADS)
Choi, Chansoo; Yeom, Yeon Soo; Nguyen, Thang Tat; Lee, Hanjin; Han, Haegin; Shin, Bangho; Zhang, Xujia; Kim, Chan Hyeong; Chung, Beom Sun
2018-01-01
For radiological protection from exposure to ionizing radiation, in which a population-averaged dose evaluation is used, establishing a system of reference anatomical and physiological data for a specific population of interest is important. Some studies were done in the past to establish Korean reference data; however, the data provided the mass values only for a limited number of organs/tissues. In addition, the standing height and total body mass are based on 20-year-old data. In the present study, a new set of Korean reference anatomical values was established for use in the radiological protection of Korean workers and members of the public. The established Korean reference data provide the masses of 58 organs/tissues, including those needed to calculate the effective dose, which were derived by collecting and analyzing various scientific reports in the literature and data. In addition, the data provide not only standing height and total body mass, but also 131 additional anthropometric parameters; these values were derived from the most recent Korean national survey project, 7 th Size Korea. The characteristics of the data were also compared with several other population data, including the Asian and the International Commission on Radiological Protection (ICRP) reference data.
Canine and feline hematology reference values for the ADVIA 120 hematology system.
Moritz, Andreas; Fickenscher, Yvonne; Meyer, Karin; Failing, Klaus; Weiss, Douglas J
2004-01-01
The ADVIA 120 is a laser-based hematology analyzer with software applications for animal species. Accurate reference values would be useful for the assessment of new hematologic parameters and for interlaboratory comparisons. The goal of this study was to establish reference intervals for CBC results and new parameters for RBC morphology, reticulocytes, and platelets in healthy dogs and cats using the ADVIA 120 hematology system. The ADVIA 120, with multispecies software (version 1.107-MS), was used to analyze whole blood samples from clinically healthy dogs (n=46) and cats (n=61). Data distribution was determined and reference intervals were calculated as 2.5 to 97.5 percentiles and 25 to 75 percentiles. Most data showed Gaussian or log-normal distribution. The numbers of RBCs falling outside the normocytic-normochromic range were slightly higher in cats than in dogs. Both dogs and cats had reticulocytes with low, medium, and high absorbance. Mean numbers of large platelets and platelet clumps were higher in cats compared with dogs. Reference intervals obtained on the ADVIA 120 provide valuable baseline information for assessing new hematologic parameters and for interlaboratory comparisons. Differences compared with previously published reference values can be attributed largely to differences in methodology.
Chew, Gina; Sim, Lay Peng; Ng, Sin Yee; Ding, Yi; Shin, Richard Y C; Lee, Tong Kooi
2016-01-01
Isotope dilution mass spectrometry and standard addition techniques were developed for the analysis of four elements (Ca, As, Cd and Pb) in a mushroom powder material. Results from the validated methods were compared to those of other national metrology institutes in the CCQM-K89 intercomparisons and the results were in excellent agreement with the reference values. The same methods were then used for the assignment of reference values to a mushroom powder Certified Reference Material (CRM). The certified values obtained for Ca, As, Cd and Pb were 1.444 ± 0.099 mg/g, 5.61 ± 0.59 mg/kg, 1.191 ± 0.079 mg/kg and 5.23 ± 0.94 mg/kg, respectively. The expanded measurement uncertainties were obtained by combining the uncertainty contributions from characterization (uchar) and between-bottle homogeneity (ubb). Copyright © 2015 Elsevier Ltd. All rights reserved.
Collaborative derivation of reference intervals for major clinical laboratory tests in Japan.
Ichihara, Kiyoshi; Yomamoto, Yoshikazu; Hotta, Taeko; Hosogaya, Shigemi; Miyachi, Hayato; Itoh, Yoshihisa; Ishibashi, Midori; Kang, Dongchon
2016-05-01
Three multicentre studies of reference intervals were conducted recently in Japan. The Committee on Common Reference Intervals of the Japan Society of Clinical Chemistry sought to establish common reference intervals for 40 laboratory tests which were measured in common in the three studies and regarded as well harmonized in Japan. The study protocols were comparable with recruitment mostly from hospital workers with body mass index ≤28 and no medications. Age and sex distributions were made equal to obtain a final data size of 6345 individuals. Between-subgroup differences were expressed as the SD ratio (between-subgroup SD divided by SD representing the reference interval). Between-study differences were all within acceptable levels, and thus the three datasets were merged. By adopting SD ratio ≥0.50 as a guide, sex-specific reference intervals were necessary for 12 assays. Age-specific reference intervals for females partitioned at age 45 were required for five analytes. The reference intervals derived by the parametric method resulted in appreciable narrowing of the ranges by applying the latent abnormal values exclusion method in 10 items which were closely associated with prevalent disorders among healthy individuals. Sex- and age-related profiles of reference values, derived from individuals with no abnormal results in major tests, showed peculiar patterns specific to each analyte. Common reference intervals for nationwide use were developed for 40 major tests, based on three multicentre studies by advanced statistical methods. Sex- and age-related profiles of reference values are of great relevance not only for interpreting test results, but for applying clinical decision limits specified in various clinical guidelines. © The Author(s) 2015.
Schimmelmann, A.; Albertino, A.; Sauer, P.E.; Qi, H.; Molinie, R.; Mesnard, F.
2009-01-01
Accurate determinations of stable isotope ratios require a calibration using at least two reference materials with different isotopic compositions to anchor the isotopic scale and compensate for differences in machine slope. Ideally, the S values of these reference materials should bracket the isotopic range of samples with unknown S values. While the practice of analyzing two isotopically distinct reference materials is common for water (VSMOW-SLAP) and carbonates (NBS 19 and L-SVEC), the lack of widely available organic reference materials with distinct isotopic composition has hindered the practice when analyzing organic materials by elemental analysis/isotope ratio mass spectrometry (EA-IRMS). At present only L-glutamic acids USGS40 and USGS41 satisfy these requirements for ??13C and ??13N, with the limitation that L-glutamic acid is not suitable for analysis by gas chromatography (GC). We describe the development and quality testing of (i) four nicotine laboratory reference materials for on-line (i.e. continuous flow) hydrogen reductive gas chromatography-isotope ratio mass-spectrometry (GC-IRMS), (ii) five nicotines for oxidative C, N gas chromatography-combustion-isotope ratio mass-spectrometry (GC-C-IRMS, or GC-IRMS), and (iii) also three acetanilide and three urea reference materials for on-line oxidative EA-IRMS for C and N. Isotopic off-line calibration against international stable isotope measurement standards at Indiana University adhered to the 'principle of identical treatment'. The new reference materials cover the following isotopic ranges: ??2Hnicotine -162 to -45%o, ??13Cnicotine -30.05 to +7.72%, ?? 15Nnicotine -6.03 to +33.62%; ??15N acetanilide +1-18 to +40.57%; ??13Curea -34.13 to +11.71%, ??15Nurea +0.26 to +40.61% (recommended ?? values refer to calibration with NBS 19, L-SVEC, IAEA-N-1, and IAEA-N-2). Nicotines fill a gap as the first organic nitrogen stable isotope reference materials for GC-IRMS that are available with different ??13N values. Comparative ??13C and ??15N on-line EA-IRMS data from 14 volunteering laboratories document the usefulness and reliability of acetanilides and ureas as EA-IRMS reference materials.
Herbert, Annie; Cruickshank, John Kennedy; Laurent, Stéphane; Boutouyrie, Pierre
2014-11-21
Estimated central systolic blood pressure (cSBP) and amplification (Brachial SBP-cSBP) are non-invasive measures potentially prognostic of cardiovascular (CV) disease. No worldwide, multiple-device reference values are available. We aimed to establish reference values for a worldwide general population standardizing between the different available methods of measurement. How these values were significantly altered by cardiovascular risk factors (CVRFs) was then investigated. Existing data from population surveys and clinical trials were combined, whether published or not. Reference values of cSBP and amplification were calculated as percentiles for 'Normal' (no CVRFs) and 'Reference' (any CVRFs) populations. We included 45,436 subjects out of 82,930 that were gathered from 77 studies of 53 centres. Included subjects were apparently healthy, not treated for hypertension or dyslipidaemia, and free from overt CV disease and diabetes. Values of cSBP and amplification were stratified by brachial blood pressure categories and age decade in turn, both being stratified by sex. Amplification decreased with age and more so in males than in females. Sex was the most powerful factor associated with amplification with 6.6 mmHg (5.8-7.4) higher amplification in males than in females. Amplification was marginally but significantly influenced by CVRFs, with smoking and dyslipidaemia decreasing amplification, but increased with increasing levels of blood glucose. Typical values of cSBP and amplification in a healthy population and a population free of traditional CVRFs are now available according to age, sex, and brachial BP, providing values included from different devices with a wide geographical representation. Amplification is significantly influenced by CVRFs, but differently in men and women. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2014. For permissions please email: journals.permissions@oup.com.
Petersen, Per H; Lund, Flemming; Fraser, Callum G; Sölétormos, György
2016-11-01
Background The distributions of within-subject biological variation are usually described as coefficients of variation, as are analytical performance specifications for bias, imprecision and other characteristics. Estimation of specifications required for reference change values is traditionally done using relationship between the batch-related changes during routine performance, described as Δbias, and the coefficients of variation for analytical imprecision (CV A ): the original theory is based on standard deviations or coefficients of variation calculated as if distributions were Gaussian. Methods The distribution of between-subject biological variation can generally be described as log-Gaussian. Moreover, recent analyses of within-subject biological variation suggest that many measurands have log-Gaussian distributions. In consequence, we generated a model for the estimation of analytical performance specifications for reference change value, with combination of Δbias and CV A based on log-Gaussian distributions of CV I as natural logarithms. The model was tested using plasma prolactin and glucose as examples. Results Analytical performance specifications for reference change value generated using the new model based on log-Gaussian distributions were practically identical with the traditional model based on Gaussian distributions. Conclusion The traditional and simple to apply model used to generate analytical performance specifications for reference change value, based on the use of coefficients of variation and assuming Gaussian distributions for both CV I and CV A , is generally useful.
Fox, Maureen; Brieva, Claudia; Moreno, Carlos; MacWilliams, Peter; Thomas, Chet
2008-12-01
The white-footed tamarin (Saguinus leucopus) is an endangered primate that lives in a small forest corridor in northern Colombia, South America. Hematologic and serum biochemistry reference values are important tools in evaluating the health of the white-footed tamarin and serve to promote the survival of this species. The purpose of this study was to establish diagnostically important hematologic and serum biochemistry reference values for healthy white-footed tamarins and to determine whether there was significant variation with respect to age class (juveniles, adults), gender, and housing facility. Blood samples were collected for hematologic and serum biochemistry measurements from 29 wild-caught captive tamarins during February and April 2005, housed at three different facilities in central Colombia. Hematology and serum biochemistry values were similar in adults and juveniles. Female white-footed tamarins had absolute reticulocyte counts that were lower than those of male tamarins and males had lower serum chloride concentrations than female tamarins. Mean values for hemoglobin, mean cell hemoglobin, serum total protein, albumin, glucose, and alkaline phosphatase varied among the three housing facilities. Twenty-two of the 29 tamarins sampled were microfilaria-positive and had significantly higher mean serum alkaline phosphatase concentrations. Among the 29 tamarins sampled in this study, serum values for mean alkaline phosphatase and creatine kinase concentrations were higher than reported values for other mammals. The reference intervals determined in this study were comparable to normal ranges reported for other members of the family Callitrichidae.
van Rooyen, Yolandi; Huisman, Hugo W; Schutte, Aletta E; Eloff, Fritz C; Du Plessis, Johan L; Kruger, Annamarie; Van Rooyen, Johannes M
2015-06-01
In South Africa respiratory diseases are highly prevalent, with cardiovascular disease being a manifestation. However, international reference values for lung function are commonly used, which may not be appropriate to correctly identify reduced lung function. An inverse relationship exists between lung function and blood pressure (BP) but is not investigated extensively in black South Africans. We included 2010 Africans from the PURE (Prospective Urban Rural Epidemiology) study (aged > 35 years) in the North West Province. Spirometry was performed and predicted values for forced expiratory volume in one second (FEV1) and forced vital capacity (FVC) were calculated from South African, European and United States prediction equations. With the exception of the European predicted values, all other predicted mean FEV1 and FVC were above 80%. South African reference values displayed the highest percentages of the predicted values for FEV1 and FVC (87.9 and 99.7%, respectively.) BP increased from quintiles five to one for both FEV1 and FVC, (p for trend <0.001). After adjustment the differences remained (p<0.05). South African reference values yielded higher percentages of predicted FEV1 and FVC values than European and US equations suggesting that South African prediction equations may be more useful when investigating lung function in black South Africans. Elevated BP is related to reduced lung function, highlighting the importance in managing both respiratory- and cardiovascular disease. Copyright © 2015 Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). Published by Elsevier B.V. All rights reserved.
De Smedt, Delphine; Clays, Els; Höfer, Stefan; Oldridge, Neil; Kotseva, Kornelia; Maggioni, Aldo Pietro; Pogosova, Nana; Dolzhenko, Maryna; De Bacquer, Dirk
2016-07-01
HeartQoL is a recently developed core health-related quality of life instrument for patients with coronary heart disease. The current study aims to investigate its association with patients' coronary risk profile and to provide reference values for patients with coronary heart disease across Europe. Analyses are based on the EUROASPIRE IV (EUROpean Action on Secondary and Primary prevention through Intervention to Reduce Events) cross-sectional survey. Patients with a diagnosis of coronary heart disease were examined and interviewed six months to three years after their coronary event. The HeartQoL questionnaire was completed by 7261 coronary heart disease patients. Reference values were calculated and the association with the coronary risk profile was assessed. Significantly worse outcomes were observed in higher-risk patient groups. Both metabolic and behavioural risk factors were associated with worse HeartQoL outcomes. Further, the HeartQoL scores decreased as the number of risk factors increased. The mean global reference values in males were 2.27 ± 0.65 (<60 years), 2.30 ± 0.61 (between 60 and 69 years) and 2.19 ± 0.64 (≥70 years). Likewise, in females, the respective global HeartQoL reference values were 2.02 ± 0.67, 2.01 ± 0.66 and 1.83 ± 0.70. The ceiling effect in males was 11.4%, 10.4% and 7.4% for the three age classes respectively, whereas in females the ceiling effect was 5.2%, 3.5% and 1.9%, respectively. HeartQoL scores were associated with patients' coronary risk profile. The reference values may help other researchers to interpret HeartQoL scores. Further research should focus on the minimal important difference needed to evaluate the effect of therapies and lifestyle changes. © The European Society of Cardiology 2016.
Cacau, Lucas de Assis Pereira; de Santana-Filho, Valter Joviniano; Maynard, Luana G; Gomes, Mansueto; Fernandes, Marcelo; Carvalho, Vitor Oliveira
2016-01-01
The aim of the study is to compare the available reference values and the six-minute walk test equations in healthy children/adolescents. Our systematic review was planned and performed in accordance with the PRISMA guidelines. We included all studies that established reference values for the six-minute walk test in healthy children/adolescents. To perform this review, a research was performed in PubMed, EMBASE (via SCOPUS) and Cochrane (LILACS), Bibliographic Index Spanish in Health Sciences, Organization Collection Pan-American Health Organization, Publications of the World Health Organization and Scientific Electronic Library Online (SciELO) via Virtual Health Library until June 2015 without language restriction. The initial research identified 276 abstracts. Twelve studies met the inclusion criteria and were fully reviewed and approved by both reviewers. None of the selected studies presented sample size calculation. Most of the studies recruited children and adolescents from school. Six studies reported the use of random samples. Most studies used a corridor of 30 meters. All studies followed the American Thoracic Society guidelines to perform the six-minute walk test. The walked distance ranged 159 meters among the studies. Of the 12 included studies, 7 (58%) reported descriptive data and 6 (50%) established reference equation for the walked distance in the six-minute walk test. The reference value for the six-minute walk test in children and adolescents ranged substantially from studies in different countries. A reference equation was not provided in all studies, but the ones available took into account well established variables in the context of exercise performance, such as height, heart rate, age and weight. Countries that did not established reference values for the six-minute walk test should be encouraged to do because it would help their clinicians and researchers have a more precise interpretation of the test.
Cacau, Lucas de Assis Pereira; de Santana-Filho, Valter Joviniano; Maynard, Luana G.; Gomes Neto, Mansueto; Fernandes, Marcelo; Carvalho, Vitor Oliveira
2016-01-01
Objective The aim of the study is to compare the available reference values and the six-minute walk test equations in healthy children/adolescents. Our systematic review was planned and performed in accordance with the PRISMA guidelines. We included all studies that established reference values for the six-minute walk test in healthy children/adolescents. Methods To perform this review, a research was performed in PubMed, EMBASE (via SCOPUS) and Cochrane (LILACS), Bibliographic Index Spanish in Health Sciences, Organization Collection Pan-American Health Organization, Publications of the World Health Organization and Scientific Electronic Library Online (SciELO) via Virtual Health Library until June 2015 without language restriction. Results The initial research identified 276 abstracts. Twelve studies met the inclusion criteria and were fully reviewed and approved by both reviewers. None of the selected studies presented sample size calculation. Most of the studies recruited children and adolescents from school. Six studies reported the use of random samples. Most studies used a corridor of 30 meters. All studies followed the American Thoracic Society guidelines to perform the six-minute walk test. The walked distance ranged 159 meters among the studies. Of the 12 included studies, 7 (58%) reported descriptive data and 6 (50%) established reference equation for the walked distance in the six-minute walk test. Conclusion The reference value for the six-minute walk test in children and adolescents ranged substantially from studies in different countries. A reference equation was not provided in all studies, but the ones available took into account well established variables in the context of exercise performance, such as height, heart rate, age and weight. Countries that did not established reference values for the six-minute walk test should be encouraged to do because it would help their clinicians and researchers have a more precise interpretation of the test. PMID:27982347
Hayata, Kei; Hiramatsu, Yuji; Masuyama, Hisashi; Etou, Eriko; Nobumoto, Etsuko; Mitsui, Takashi
2015-12-01
We created a new reference standard focusing on the hemispheric anteroposterior cerebellar diameter (APCD) in addition to the transverse cerebellar diameter (TCD) and discussed whether or not the cerebellar measurement was useful for the detection of trisomy 18 (T18). In 150 normal fetuses between 14 and 36 weeks of gestational age (GA), the TCD and APCD were prospectively measured. In 26 cases with T18, the value was compared with the control. At <22 weeks of gestation, the TCD reference standard was calculated as follows: TCD = (1.027 × GA) - 0.674 (R(2) = 0.97, P < 0.001). The reference standard of the APCD was calculated as follows: APCD = (0.682 × GA) - 3.925 (R(2) = 0.73, P < 0.001). In eight cases with T18, the TCD was below the 5th percentile value in 7/8 (88%) cases and the APCD was below the 5th percentile value in 8/8 (100%) cases. At >22 weeks of gestation, the reference standard of the TCD was calculated as follows: TCD = (1.603 × GA) - 13.216 (R(2) = 0.92, P < 0.001). The reference standard of the APCD was calculated as follows: APCD = (0.859 × GA) - 7.30 (R(2) = 0.84, P < 0.001). In 18 cases with T18, the TCD was below the 5th percentile value in 14/18 (78%) cases and the APCD was below the 5th percentile value in 18/18 (100%) cases. APCD reference standard, divided by the gestational age of more or less than 22 weeks, might be useful to diagnose T18. © 2015 Japan Society of Obstetrics and Gynecology.
Nilsson, Markus; Szczepankiewicz, Filip; van Westen, Danielle; Hansson, Oskar
2015-01-01
Conventional motion and eddy-current correction, where each diffusion-weighted volume is registered to a non diffusion-weighted reference, suffers from poor accuracy for high b-value data. An alternative approach is to extrapolate reference volumes from low b-value data. We aim to compare the performance of conventional and extrapolation-based correction of diffusional kurtosis imaging (DKI) data, and to demonstrate the impact of the correction approach on group comparison studies. DKI was performed in patients with Parkinson's disease dementia (PDD), and healthy age-matched controls, using b-values of up to 2750 s/mm2. The accuracy of conventional and extrapolation-based correction methods was investigated. Parameters from DTI and DKI were compared between patients and controls in the cingulum and the anterior thalamic projection tract. Conventional correction resulted in systematic registration errors for high b-value data. The extrapolation-based methods did not exhibit such errors, yielding more accurate tractography and up to 50% lower standard deviation in DKI metrics. Statistically significant differences were found between patients and controls when using the extrapolation-based motion correction that were not detected when using the conventional method. We recommend that conventional motion and eddy-current correction should be abandoned for high b-value data in favour of more accurate methods using extrapolation-based references.
Determination of Age-Dependent Reference Ranges for Coagulation Tests Performed Using Destiny Plus
Arslan, Fatma Demet; Serdar, Muhittin; Merve Ari, Elif; Onur Oztan, Mustafa; Hikmet Kozcu, Sureyya; Tarhan, Huseyin; Cakmak, Ozgur; Zeytinli, Merve; Yasar Ellidag, Hamit
2016-01-01
Background In order to apply the right treatment for hemostatic disorders in pediatric patients, laboratory data should be interpreted with age-appropriate reference ranges. Objectives The purpose of this study was to determining age-dependent reference range values for prothrombin time (PT), activated partial thromboplastin time (aPTT), fibrinogen tests, and D-dimer tests. Materials and Methods A total of 320 volunteers were included in the study with the following ages: 1 month - 1 year (n = 52), 2 - 5 years (n = 50), 6 - 10 years (n = 48), 11 - 17 years (n = 38), and 18 - 65 years (n = 132). Each volunteer completed a survey to exclude hemostatic system disorder. Using a nonparametric method, the lower and upper limits, including 95% distribution and 90% confidence intervals, were calculated. Results No statistically significant differences were found between PT and aPTT values in the groups consisting of children. Thus, the reference ranges were separated into child and adult age groups. PT and aPTT values were significantly higher in the children than in the adults. Fibrinogen values in the 6 - 10 age group and the adult age group were significantly higher than in the other groups. D-dimer levels were significantly lower in those aged 2 - 17; thus, a separate reference range was established. Conclusions These results support other findings related to developmental hemostasis, confirming that adult and pediatric age groups should be evaluated using different reference ranges. PMID:27617078
Leong, Darryl P; Teo, Koon K; Rangarajan, Sumathy; Kutty, V Raman; Lanas, Fernando; Hui, Chen; Quanyong, Xiang; Zhenzhen, Qian; Jinhua, Tang; Noorhassim, Ismail; AlHabib, Khalid F; Moss, Sarah J; Rosengren, Annika; Akalin, Ayse Arzu; Rahman, Omar; Chifamba, Jephat; Orlandini, Andrés; Kumar, Rajesh; Yeates, Karen; Gupta, Rajeev; Yusufali, Afzalhussein; Dans, Antonio; Avezum, Álvaro; Lopez-Jaramillo, Patricio; Poirier, Paul; Heidari, Hosein; Zatonska, Katarzyna; Iqbal, Romaina; Khatib, Rasha; Yusuf, Salim
2016-12-01
The measurement of handgrip strength (HGS) has prognostic value with respect to all-cause mortality, cardiovascular mortality and cardiovascular disease, and is an important part of the evaluation of frailty. Published reference ranges for HGS are mostly derived from Caucasian populations in high-income countries. There is a paucity of information on normative HGS values in non-Caucasian populations from low- or middle-income countries. The objective of this study was to develop reference HGS ranges for healthy adults from a broad range of ethnicities and socioeconomically diverse geographic regions. HGS was measured using a Jamar dynamometer in 125,462 healthy adults aged 35-70 years from 21 countries in the Prospective Urban Rural Epidemiology (PURE) study. HGS values differed among individuals from different geographic regions. HGS values were highest among those from Europe/North America, lowest among those from South Asia, South East Asia and Africa, and intermediate among those from China, South America, and the Middle East. Reference ranges stratified by geographic region, age, and sex are presented. These ranges varied from a median (25 th -75 th percentile) 50 kg (43-56 kg) in men <40 years from Europe/North America to 18 kg (14-20 kg) in women >60 years from South East Asia. Reference ranges by ethnicity and body-mass index are also reported. Individual HGS measurements should be interpreted using region/ethnic-specific reference ranges.
Fidler Mis, Nataša; Kobe, Helena; Stimec, Matevž
2012-01-01
Data on a nationally representative dietary intake in Central Europe is lacking. We investigated the diet of adolescents in Slovenia. Dietary habits were assessed using a food frequency questionnaire (n = 2,661), and present nutrition was assessed using a 3-day weighted dietary protocol (n = 197) for validation purposes. Dietary intake was calculated and compared with Central European [German (D), Austrian (A), and Swiss (CH); D-A-CH] recommendations and World Health Organization/Food and Agriculture Organization (WHO/FAO) recommendations. Adolescents consumed exceeding reference intake values of free sugars (boys 16% of energy, girls 17%), saturated fatty acids (SFA; 13% of energy), and sodium (boys 203%, girls 210% of the WHO/FAO upper limit), but below-reference intake values of polyunsaturated fatty acids (PUFA; boys 5% of energy; girls 6%), water (boys 1,786 ml/day, girls 2,016 ml/day), and fiber density (only girls 2.8 g/MJ, p < 0.001). Among micronutrients, below-reference intakes (% of D-A-CH: boys and girls, respectively, p < 0.05) were reported for folate (64 and 69%), fluoride (28 and 31%), and calcium (91 and 97%), as well as for vitamin D (20 and 20%). The dietary habits of Slovenian adolescents are less than optimal. They are characterized by exceeding reference intake values of free sugars, salt, and SFA, and a below-reference intake of PUFA, water, and several micronutrients. Copyright © 2012 S. Karger AG, Basel.
Jensen, Roxanne E; Potosky, Arnold L; Moinpour, Carol M; Lobo, Tania; Cella, David; Hahn, Elizabeth A; Thissen, David; Smith, Ashley Wilder; Ahn, Jaeil; Luta, George; Reeve, Bryce B
2017-06-10
Purpose To estimate cancer population-based reference values in the United States for eight PROMIS (Patient-Reported Outcomes Measurement Information System) domains by age and stage of disease. Patients and Methods For the Measuring Your Health (MY-Health) study, persons newly diagnosed with cancer (prostate, colorectal, non-small-cell lung, non-Hodgkin lymphoma, breast, uterine, or cervical) from 2010 to 2012 (N = 5,284) were recruited through the National Cancer Institute's SEER Program. Participants were mailed surveys 6 to 13 months after diagnosis. Raking by race/ethnicity, age, and stage generated weighted average PROMIS scores for pain interference, fatigue, anxiety, depression, sleep disturbance, physical function, ability to participate in social roles, and cognitive function. PROMIS measures are standardized to a T-score metric, with a score of 50 representing the general US population mean. Clinically meaningful differences were defined as a 3-point difference in scores. Results Several reference values (means) for patients with cancer were worse than the general United States population norms of 50. These include pain interference (52.4), fatigue (52.2), and physical function (44.1). Reference values were highest (ie, showed greatest symptom burden) in lung cancer (pain interference, 55.5; fatigue, 57.3; depression, 51.4) and cervical cancer (anxiety, 53.2; sleep disturbance, 53.4). Reference values for patients age 65 to 84 years reported lower sleep disturbance, anxiety, and depression, and better cognitive function than younger patients. Cancer reference values were poorer among those with advanced disease compared with patients with limited or no evidence of disease, specifically physical function (41.1 v 46.6, respectively), fatigue (55.8 v 50.2, respectively), and pain interference (55.2 v 50.9, respectively). Conclusion In a large, population-based sample of patients with recently diagnosed cancer, we observed symptom severity and functional deficits by age, stage, and cancer type consistent with the expected impact of cancer diagnosis and treatment. These United States cancer reference values can help facilitate interpretation of the PROMIS domain scores in research studies or in clinical applications that measure and evaluate the symptom and functional burden patients with cancer experience after initial treatment.
Method and apparatus for displaying information
NASA Technical Reports Server (NTRS)
Huang, Sui (Inventor); Eichler, Gabriel (Inventor); Ingber, Donald E. (Inventor)
2010-01-01
A method for displaying large amounts of information. The method includes the steps of forming a spatial layout of tiles each corresponding to a representative reference element; mapping observed elements onto the spatial layout of tiles of representative reference elements; assigning a respective value to each respective tile of the spatial layout of the representative elements; and displaying an image of the spatial layout of tiles of representative elements. Each tile includes atomic attributes of representative elements. The invention also relates to an apparatus for displaying large amounts of information. The apparatus includes a tiler forming a spatial layout of tiles, each corresponding to a representative reference element; a comparator mapping observed elements onto said spatial layout of tiles of representative reference elements; an assigner assigning a respective value to each respective tile of said spatial layout of representative reference elements; and a display displaying an image of the spatial layout of tiles of representative reference elements.
Population based haematology reference ranges for old people in rural South-West Uganda.
Mugisha, Joseph O; Seeley, Janet; Kuper, Hannah
2016-09-07
Haematology reference values are needed to interpret haematology results and make clinical decisions, but these have not been established for old people in sub-Saharan Africa. The objective of this study was to establish haematology reference values for people aged 50 years and above in Uganda, to compare the haematology reference values for those aged 65 years and over with those less than 65 years and to compare these haematology reference values with established haematology reference values for old people from high income countries. A total of 1449 people aged 50 years and above were recruited from the Medical Research Council/Uganda Virus Research Institute general population cohort between January 2012 and January 2013 (response rate 72.3 %). From the blood samples collected, we did haematology, HIV testing and malaria tests. We also obtained stool samples and tested them for hookworm infection. Questionnaire data were obtained through interviews. In the analysis, we excluded those with HIV infection, malaria infection, hookworm infection and those not feeling well at the time of recruitment. Medians and reference ranges for 12 haematology parameters were determined, based on the Clinical Laboratory and Standards institute's guidelines. In total, 903 people aged 50 years and above were included in the analysis with the majority 545 (60.3 %) being female. Men had significant difference in median haemoglobin, haematocrit, erythrocytes counts and white blood cells counts, which were higher than those of women. Women had significant difference in mean platelet counts and neutrophil percentages which were higher than those of men. Comparing those aged 65+ and those aged less than 65 years, the following parameters were significantly lower in those aged above 65 years: haemoglobin, haematocrit, erythrocytes counts, platelets and mean corpuscular volume. Compared to the reference intervals from old people in high income countries, all the haematology parameters from our study population were low. The differences between haematology reference ranges in old people compared to adults and the very old (65+) compared to those between 50 and 65 call for more population based studies using nationwide surveys to be carried out among old people in other study settings in Uganda and the rest of Africa to explore the differences in haematology reference ranges between these different age groups with a view of establishing whether there is need to have separate reference range for these different categories of old people.
Fan, Bo; Shepherd, John A; Levine, Michael A; Steinberg, Dee; Wacker, Wynn; Barden, Howard S; Ergun, David; Wu, Xin P
2014-01-01
The National Health and Nutrition Examination Survey (NHANES 1999-2004) includes adult and pediatric comparisons for total body bone and body composition results. Because dual-energy x-ray absorptiometry (DXA) measurements from different manufacturers are not standardized, NHANES reference values currently are applicable only to a single make and model of Hologic DXA system. The purpose of this study was to derive body composition reference curves for GE Healthcare Lunar DXA systems. Published values from the NHANES 1999-2004 survey were acquired from the Centers for Disease Control and Prevention website. Using previously reported cross-calibration equations between Hologic and GE-Lunar, we converted the total body and regional bone and soft-tissue measurements from NHANES 1999-2004 to GE-Lunar values. The LMS (LmsChartMaker Pro Version 3.5) curve fitting method was used to generate GE-Lunar reference curves. Separate curves were generated for each sex and ethnicity. The reference curves were also divided into pediatric (≤20 years old) and adult (>20 years old) groups. Adult reference curves were derived as a function of age. Additional relationships of pediatric DXA values were derived as a function of height, lean mass, and bone area. Robustness was tested between Hologic and GE-Lunar Z-score values. The NHANES 1999-2004 survey included a sample of 20,672 participants' (9630 female) DXA scans. A total of 8056 participants were younger than 20 yr and were included in the pediatric reference data set. Participants enrolled in the study who weighed more than 136 kg (over scanner table limit) were excluded. The average Z-scores comparing the new GE-Lunar reference curves are close to zero, and the standard deviation of the Z-scores are close to one for all variables. As expected, all measurements on the GE-Lunar reference curves for participants younger than 20 yr increase monotonically with age. In the adult population, most of the curves are constant at younger age and drop moderately as age increases. We have presented NHANES reference curves applicable to DXA whole-body scans acquired on GE Healthcare Lunar systems by age, sex and ethnicity. Users of GE Healthcare GE-Lunar DXA systems can now benefit from the large body composition reference data set collected in the NHANES 1999-2004 study. Copyright © 2014 The International Society for Clinical Densitometry. Published by Elsevier Inc. All rights reserved.
[Investigation of reference intervals of blood gas and acid-base analysis assays in China].
Zhang, Lu; Wang, Wei; Wang, Zhiguo
2015-10-01
To investigate and analyze the upper and lower limits and their sources of reference intervals in blood gas and acid-base analysis assays. The data of reference intervals were collected, which come from the first run of 2014 External Quality Assessment (EQA) program in blood gas and acid-base analysis assays performed by National Center for Clinical Laboratories (NCCL). All the abnormal values and errors were eliminated. Data statistics was performed by SPSS 13.0 and Excel 2007 referring to upper and lower limits of reference intervals and sources of 7 blood gas and acid-base analysis assays, i.e. pH value, partial pressure of carbon dioxide (PCO2), partial pressure of oxygen (PO2), Na+, K+, Ca2+ and Cl-. Values were further grouped based on instrument system and the difference between each group were analyzed. There were 225 laboratories submitting the information on the reference intervals they had been using. The three main sources of reference intervals were National Guide to Clinical Laboratory Procedures [37.07% (400/1 079)], instructions of instrument manufactures [31.23% (337/1 079)] and instructions of reagent manufactures [23.26% (251/1 079)]. Approximately 35.1% (79/225) of the laboratories had validated the reference intervals they used. The difference of upper and lower limits in most assays among 7 laboratories was moderate, both minimum and maximum (i.e. the upper limits of pH value was 7.00-7.45, the lower limits of Na+ was 130.00-156.00 mmol/L), and mean and median (i.e. the upper limits of K+ was 5.04 mmol/L and 5.10 mmol/L, the upper limits of PCO2 was 45.65 mmHg and 45.00 mmHg, 1 mmHg = 0.133 kPa), as well as the difference in P2.5 and P97.5 between each instrument system group. It was shown by Kruskal-Wallis method that the P values of upper and lower limits of all the parameters were lower than 0.001, expecting the lower limits of Na+ with P value 0.029. It was shown by Mann-Whitney that the statistic differences were found among instrument system groups and between most of two instrument system groups in all assays. The difference of reference intervals of blood gas and acid-base analysis assays used in China laboratories is moderate, which is better than other specialties in clinical laboratories.
Franssen, Frits M E; Rutten, Erica P A; Groenen, Miriam T J; Vanfleteren, Lowie E; Wouters, Emiel F M; Spruit, Martijn A
2014-06-01
Low fat-free mass (FFM) is a risk factor for morbidity and mortality in elderly and patient populations. Therefore, measurement of FFM is important in nutritional assessment. Bioelectrical impedance analysis (BIA) is a convenient method to assess FFM and FFM index (FFMI; FFM/height(2)). Although reference values have been established for individuals with normal body weight, no specific cutoff values are available for overweight and obese populations. Also, limited studies accounted for the age-related decline in FFM. To determine BMI- and age-specific reference values for abnormal low FFM(I) in white-ethnic men and women free of self-reported disease from the general population. The UK Biobank is a prospective epidemiological study of the general population from the United Kingdom. Individuals in the age category 45 to 69 years were analyzed. In addition to body weight, FFM and FFMI were measured using a Tanita BC-418MA. Also, self-reported chronic conditions and ethnic background were registered, and lung function was assessed using spirometry. After exclusion of all individuals with missing data, nonwhite ethnicity, self-reported disease, body mass index (BMI) less than 14 or 36 kg/m(2) or higher, and/or an obstructive lung function, reference values for FFM and FFMI were derived from 186,975 individuals (45.9% men; age: 56.9 ± 6.8 years; BMI: 26.5 ± 3.6 kg/m(2); FFMI 18.3 ± 2.4 kg/m(2)). FFM and FFMI were significantly associated with BMI and decreased with age. Percentiles 5, 10, 25, 50, 75, 90, and 95 were calculated for FFM, FFMI, and fat mass (index), after stratification for gender, age, and BMI. Using the UK Biobank dataset, new reference values for body composition assessed with BIA were determined in white-ethnic men and women aged 45 to 69 years. Because these reference values are BMI specific, they are of broad interest for overweight and obese populations. Copyright © 2014 American Medical Directors Association, Inc. Published by Elsevier Inc. All rights reserved.
Broughton, Heather M; Govender, Danny; Shikwambana, Purvance; Chappell, Patrick; Jolles, Anna
2017-06-01
The International Species Information System has set forth an extensive database of reference intervals for zoologic species, allowing veterinarians and game park officials to distinguish normal health parameters from underlying disease processes in captive wildlife. However, several recent studies comparing reference values from captive and free-ranging animals have found significant variation between populations, necessitating the development of separate reference intervals in free-ranging wildlife to aid in the interpretation of health data. Thus, this study characterizes reference intervals for six biochemical analytes, eleven hematologic or immune parameters, and three hormones using samples from 219 free-ranging African lions ( Panthera leo ) captured in Kruger National Park, South Africa. Using the original sample population, exclusion criteria based on physical examination were applied to yield a final reference population of 52 clinically normal lions. Reference intervals were then generated via 90% confidence intervals on log-transformed data using parametric bootstrapping techniques. In addition to the generation of reference intervals, linear mixed-effect models and generalized linear mixed-effect models were used to model associations of each focal parameter with the following independent variables: age, sex, and body condition score. Age and sex were statistically significant drivers for changes in hepatic enzymes, renal values, hematologic parameters, and leptin, a hormone related to body fat stores. Body condition was positively correlated with changes in monocyte counts. Given the large variation in reference values taken from captive versus free-ranging lions, it is our hope that this study will serve as a baseline for future clinical evaluations and biomedical research targeting free-ranging African lions.
SCUD: fast structure clustering of decoys using reference state to remove overall rotation.
Li, Hongzhi; Zhou, Yaoqi
2005-08-01
We developed a method for fast decoy clustering by using reference root-mean-squared distance (rRMSD) rather than commonly used pairwise RMSD (pRMSD) values. For 41 proteins with 2000 decoys each, the computing efficiency increases nine times without a significant change in the accuracy of near-native selections. Tests on additional protein decoys based on different reference conformations confirmed this result. Further analysis indicates that the pRMSD and rRMSD values are highly correlated (with an average correlation coefficient of 0.82) and the clusters obtained from pRMSD and rRMSD values are highly similar (the representative structures of the top five largest clusters from the two methods are 74% identical). SCUD (Structure ClUstering of Decoys) with an automatic cutoff value is available at http://theory.med.buffalo.edu. (c) 2005 Wiley Periodicals, Inc.
Establishing Normative Reference Values for Handgrip among Hungarian Youth
ERIC Educational Resources Information Center
Saint-Maurice, Pedro F.; Laurson, Kelly R.; Karsai, István; Kaj, Mónika; Csányi, Tamás
2015-01-01
Purpose: The purpose of this study was to examine age- and sex-related variation in handgrip strength and to determine reference values for the Hungarian population. Method: A sample of 1,086 Hungary youth (aged 11-18 years old; 654 boys and 432 girls) completed a handgrip strength assessment using a handheld dynamometer. Quantile regression was…
USDA-ARS?s Scientific Manuscript database
Near-Infrared reflectance spectroscopic prediction models were developed for common constituents of corn and soybeans using bulk reference values and mean spectra from single-seeds. The bulk reference model and a true single-seed model for soybean protein were compared to determine how well the bul...
A novel method for the activity measurement of large-area beta reference sources.
Stanga, D; De Felice, P; Keightley, J; Capogni, M; Ioan, M R
2016-03-01
A novel method has been developed for the activity measurement of large-area beta reference sources. It makes use of two emission rate measurements and is based on the weak dependence between the source activity and the activity distribution for a given value of transmission coefficient. The method was checked experimentally by measuring the activity of two ((60)Co and (137)Cs) large-area reference sources constructed from anodized aluminum foils. Measurement results were compared with the activity values measured by gamma spectrometry. For each source, they agree within one standard uncertainty and also agree within the same limits with the certified values of the source activity. Copyright © 2015 Elsevier Ltd. All rights reserved.
Qureshi, Waqas T.; Leigh, J. Adam; Swett, Katrina; Ajay, Dharod; Allison, Matthew A.; Cai, Jianwen; Gonzalez, Franklyn; Hurwitz, Barry E.; Shah, Sanjiv J.; Desai, Ankit A.; Spevack, Daniel M.; Rodriguez, Carlos J.
2015-01-01
Background Reference limits for echocardiographic quantification of cardiac chambers in Hispanics are not well studied. Methods and Results We examined the reference values of left atrium (LA) and ventricle (LV) structure in a large ethnically diverse Hispanic cohort. Two-dimensional transthoracic echocardiography was performed in 1,818 participants of the Echocardiographic Study of Latinos (ECHO-SOL). Individuals with body mass index ≥30kg/m2, hypertension, diabetes mellitus, coronary artery disease and atrial fibrillation were excluded leaving 525 participants defined as healthy reference-cohort. We estimated 95th weighted percentiles of LV end systolic volume, LV end diastolic volume, relative wall and septal thickness, LV mass and left atrial volume. We then used upper reference limits of the 2005 and 2015 American Society of Echocardiography (ASE) and 95th percentile of reference cohort to classify the Hispanic Community Health Study/Study of Latinos (HCHS/SOL) target population into abnormal and normal. Reference limits were also calculated for each of 6 Hispanic origins. Using ASE 2015 defined reference values we categorized 7%, 21%, 57% and 17% of males and 18%, 29%, 60% and 26% of females as having abnormal LV mass index, relative, septal and posterior wall thickness, respectively. Conversely, 10%, and 11% of males and 4% and 2% of females were classified as having abnormal end-diastolic volume and internal diameter by ASE 2015 cut-offs, respectively. Similar differences were found when we used 2005 ASE cut offs. Several differences were noted in distribution of cardiac structure and volumes among various Hispanic/Latino origins. Cubans had highest values of echocardiographic measures and Central Americans had the lowest. Conclusions This is the first large study that provides normal reference values for cardiac structure. It further demonstrates that a considerable segment of Hispanic/Latinos residing in US may be classified as having abnormal measures of cardiac chambers when 2015 and 2005 ASE reference cut-offs are used. PMID:26712159
Kim, Chang-Sei; Carek, Andrew M.; Mukkamala, Ramakrishna; Inan, Omer T.; Hahn, Jin-Oh
2015-01-01
Goal We tested the hypothesis that the ballistocardiogram (BCG) waveform could yield a viable proximal timing reference for measuring pulse transit time (PTT). Methods From fifteen healthy volunteers, we measured PTT as the time interval between BCG and a non-invasively measured finger blood pressure (BP) waveform. To evaluate the efficacy of the BCG-based PTT in estimating BP, we likewise measured pulse arrival time (PAT) using the electrocardiogram (ECG) as proximal timing reference and compared their correlations to BP. Results BCG-based PTT was correlated with BP reasonably well: the mean correlation coefficient (r) was 0.62 for diastolic (DP), 0.65 for mean (MP) and 0.66 for systolic (SP) pressures when the intersecting tangent method was used as distal timing reference. Comparing four distal timing references (intersecting tangent, maximum second derivative, diastolic minimum and systolic maximum), PTT exhibited the best correlation with BP when the systolic maximum method was used (mean r value was 0.66 for DP, 0.67 for MP and 0.70 for SP). PTT was more strongly correlated with DP than PAT regardless of the distal timing reference: mean r value was 0.62 versus 0.51 (p=0.07) for intersecting tangent, 0.54 versus 0.49 (p=0.17) for maximum second derivative, 0.58 versus 0.52 (p=0.37) for diastolic minimum, and 0.66 versus 0.60 (p=0.10) for systolic maximum methods. The difference between PTT and PAT in estimating DP was significant (p=0.01) when the r values associated with all the distal timing references were compared altogether. However, PAT appeared to outperform PTT in estimating SP (p=0.31 when the r values associated with all the distal timing references were compared altogether). Conclusion We conclude that BCG is an adequate proximal timing reference in deriving PTT, and that BCG-based PTT may be superior to ECG-based PAT in estimating DP. Significance PTT with BCG as proximal timing reference has potential to enable convenient and ubiquitous cuffless BP monitoring. PMID:26054058
ERIC Educational Resources Information Center
Rothstein, Samuel
1989-01-01
Discusses measurement and evaluation as ways to justify reference work to users and library administration. A trivia contest is cited as a way to achieve public recognition, and measuring use of reference materials rather than the number of reference questions is recommended. User surveys and other measures of reference activity and value are also…
New Reference Values for Vitamin C Intake.
2015-01-01
The German, Austrian, and Swiss nutrition societies are the editors of the 'reference values for nutrient intake'. They have revised the reference values for the intake of vitamin C and published them in February 2015. The average vitamin C requirement in healthy adults is considered to be the vitamin C amount that compensates for the metabolic losses of vitamin C, and ensures a fasting ascorbate plasma level of 50 µmol/l. Based on the present data from studies with non-smoking men, metabolic losses of 50 mg/day are assumed, as well as an absorption rate of 80% and an urinary excretion of 25% of the vitamin C intake. Taking this into account, the calculated average requirement in men is 91 mg/day. Considering a coefficient of variation of 10%, a reference value (recommended intake) of 110 mg/day for men is derived. The vitamin C requirement in women as well as in children and adolescents is extrapolated from the requirement in men and in relation to their body weight. This results in a recommended intake of about 95 mg/day for adult women. Because the requirement in pregnant and lactating women is increased, higher recommended intakes are derived for them, 105 mg/day for pregnant women from the fourth month on and 125 mg/day for lactating women, respectively. For boys and girls at the age of 1 to under 15 years, there are increasing recommended intake values from 20 to 85 mg/day. For male and female adolescents, at the age of 15 to under 19 years, the recommended intake is 105 and 90 mg, respectively. As smokers have higher metabolic losses and lower plasma levels of vitamin C than non-smokers (turnover is 40% higher), the reference value for vitamin C intake is set to 135 mg/day for female smokers and 155 mg/day for male smokers. For infants in their first year of life, the reference value (estimated value) is set to 20 mg vitamin C/ day, based upon the lowest observed vitamin C intake for infants in the United Kingdom and the United States, that obviously meets the requirement in infants and that is 3 times higher than the amount necessary to prevent scurvy (7 mg/day). © 2015 S. Karger AG, Basel.
Chang, Yu-Hsun; Yang, Shang-Hsien; Wang, Tso-Fu; Lin, Teng-Yi; Yang, Kuo-Liang; Chen, Shu-Huey
2011-06-01
Cord blood banking has become more popular in recent years. Checking cord blood complete blood count (CBC) and white blood cell (WBC) differential counts (DCs) is essential before cryopreserving the cord blood units. Therefore, establishing the normal reference values of cord blood CBC and WBC DC is important in clinical practice and research. To obtain a large-scale population-based normal CBC and WBC DC reference values of healthy neonates' cord blood from a public cord blood bank and to investigate the influence of the gender and delivery route. From September 2001 to November 2006, the cord blood of healthy Taiwanese neonates with gestational age 36 weeks and more were collected by Tzu Chi Cord Blood Bank with written informed consents. All cord blood samples were analyzed by Sysmex XE2100 automated hematology analyzer (Sysmex Corporation, Kobe, Japan) to obtain the CBC. The WBC DC was calculated by manual method. We used Student's t test and Mann-Whitney U test for investigating the influences of gender and delivery route on the CBC and WBC DC reference values. The results were presented by mean±standard deviation or 2.5-97.5th percentiles. In the study period, totally 5602 cord blood samples were collected eligibly for analysis. The cord blood CBC and WBC DC normal reference values were calculated. The female neonates had significantly higher mean corpuscular volume, platelet count, and WBC count, but lower red blood cell (RBC) count, hemoglobin (Hb), hematocrit, and mean corpuscular Hb concentration values (p<0.001). Newborns through vaginal delivery had significantly higher RBC count, Hb, hematocrit, platelet count, and WBC count (p<0.001). The percentages of some different types WBC were significantly influenced by gender and delivery routes. Male babies had higher lymphocyte, monocyte, eosinophil, basophil, and nucleated RBC ratios than the female neonates. Newborns through cesarean section had significantly lower neutrophil, monocyte, and nucleated RBC ratios, but higher lymphocyte and eosinophil ratios, than newborns through vaginal delivery. We successfully obtained the normal CBC and WBC DC reference values of the cord blood in Taiwan. Gender and delivery routes were important confounding factors that influenced the cord blood CBC and WBC DC values. Copyright © 2011. Published by Elsevier B.V.
Reference hematologic and plasma chemistry values of brown tree snakes (Boiga irregularis).
Lamirande, E W; Bratthauer, A D; Fischer, D C; Nichols, D K
1999-12-01
Reference hematologic and plasma chemistry values were determined from 103 blood samples collected from 53 clinically healthy brown tree snakes (Boiga irregularis). Female snakes had significantly higher mean plasma values for total solids, total protein, calcium (Ca), phosphorus (P), uric acid, and blood monocyte percentage than did males, whereas males had significantly higher mean plasma fibrinogen values. The variances for hematocrit, monocyte percentage, azurophil percentage, plasma total solids, plasma total protein, albumin, Ca, and P also differed significantly between sexes. The higher mean values and greater variances for plasma total protein, plasma total solids, Ca, and P in the female snakes were probably associated with yolk synthesis and accumulation.
Reference values for muscle strength: a systematic review with a descriptive meta-analysis.
Benfica, Poliana do Amaral; Aguiar, Larissa Tavares; Brito, Sherindan Ayessa Ferreira de; Bernardino, Luane Helena Nunes; Teixeira-Salmela, Luci Fuscaldi; Faria, Christina Danielli Coelho de Morais
2018-05-03
Muscle strength is an important component of health. To describe and evaluate the studies which have established the reference values for muscle strength on healthy individuals and to synthesize these values with a descriptive meta-analysis approach. A systematic review was performed in MEDLINE, LILACS, and SciELO databases. Studies that investigated the reference values for muscle strength of two or more appendicular/axial muscle groups of health individuals were included. Methodological quality, including risk of bias was assessed by the QUADAS-2. Data extracted included: country of the study, sample size, population characteristics, equipment/method used, and muscle groups evaluated. Of the 414 studies identified, 46 were included. Most of the studies had adequate methodological quality. Included studies evaluated: appendicular (80.4%) and axial (36.9%) muscles; adults (78.3%), elderly (58.7%), adolescents (43.5%), children (23.9%); isometric (91.3%) and isokinetic (17.4%) strength. Six studies (13%) with similar procedures were synthesized with meta-analysis. Generally, the coefficient of variation values that resulted from the meta-analysis ranged from 20.1% to 30% and were similar to those reported by the original studies. The meta-analysis synthesized the reference values of isometric strength of 14 muscle groups of the dominant/non-dominant sides of the upper/lower limbs of adults/elderly from developed countries, using dynamometers/myometer. Most of the included studies had adequate methodological quality. The meta-analysis provided reference values for the isometric strength of 14 appendicular muscle groups of the dominant/non-dominant sides, measured with dynamometers/myometers, of men/women, of adults/elderly. These data may be used to interpret the results of the evaluations and establish appropriate treatment goals. Copyright © 2018 Associação Brasileira de Pesquisa e Pós-Graduação em Fisioterapia. Publicado por Elsevier Editora Ltda. All rights reserved.
Muraru, Denisa; Onciul, Sebastian; Peluso, Diletta; Soriani, Nicola; Cucchini, Umberto; Aruta, Patrizia; Romeo, Gabriella; Cavalli, Giacomo; Iliceto, Sabino; Badano, Luigi P
2016-02-01
Despite the fact that assessment of right ventricular longitudinal strain (RVLS) carries important implications for patient diagnosis, prognosis, and treatment, its implementation in clinical settings has been hampered by the limited reference values and the lack of uniformity in software, method, and definition used for measuring RVLS. Accordingly, this study was designed to establish (1) the reference values for RVLS by 2-dimensional speckle-tracking echocardiography; and (2) their relationship with demographic, hemodynamic, and cardiac factors. In 276 healthy volunteers (55% women; age, 18-76 years), free wall and septum RVLS (6 segments) and free wall RVLS (3 segments) using both 6- and 3-segment regions of interest were obtained. Feasibility of 6-segment RVLS was 92%. Free wall RVLS from 3- versus 6-segment regions of interest had similar values, yet 6-segment region of interest was more feasible (86% versus 73%; P<0.001) and reproducible. Reference values (lower limits of normality) were as follows: 6-segment RVLS, -24.7±2.6% (-20.0%) for men and -26.7±3.1% (-20.3%) for women; 3-segment RVLS, -29.3±3.4% (-22.5%) for men and -31.6±4.0% (-23.3%) for women (P<0.001). Free wall RVLS was 5±2 strain units (%) larger in magnitude than 6-segment RVLS, 10±4% larger than septal RVLS, and 2±4% larger in women than in men (P<0.001). At multivariable analysis, age, sex, pulmonary systolic pressure, right atrial minimal volume, as well as right atrial and left ventricular longitudinal strain resulted as correlates of RVLS values. This is the largest study providing sex- and method-specific reference values for RVLS. Our data may foster the implementation of 2-dimensional speckle-tracking echocardiography-derived RV analysis in clinical practice. © 2016 American Heart Association, Inc.
Lemaillet, Paul; Bouchard, Jean-Pierre; Allen, David W
2015-07-01
The development of a national reference instrument dedicated to the measurement of the scattering and absorption properties of solid tissue-mimicking phantoms used as reference standards is presented. The optical properties of the phantoms are measured with a double-integrating sphere setup in the steady-state domain, coupled with an inversion routine of the adding-doubling procedure that allows for the computation of the uncertainty budget for the measurements. The results are compared to the phantom manufacturer's values obtained by a time-resolved approach. The results suggest that the agreement between these two independent methods is within the estimated uncertainties. This new reference instrument will provide optical biomedical research laboratories with reference values for absolute diffuse optical properties of phantom materials.
Beaufrère, Hugues; Acierno, Mark; Mitchell, Mark; Guzman, David Sanchez-Migallon; Bryant, Heather; Tully, Thomas N
2011-06-01
Birds are routinely presented to veterinarians for dehydration. Success with these cases ultimately depends on providing replacement fluids and re-establishing fluid homeostasis. Few studies have been done to determine reference ranges for plasma osmolality in birds. The goals of this study were to determine reference values for plasma osmolality in 3 species of parrots and to provide recommendations on fluid selection for replacement therapy in these species. Blood samples were collected from 21 adult Hispaniolan Amazon parrots (Amazona ventralis), 21 Congo African grey parrots (Psittacus erithacus erithacus), and 9 red-fronted macaws (Ara rubrogenys), and were placed into lithium heparin containers. Plasma osmolality was measured in duplicate with a freezing point depression osmometer. Summary statistics were computed from the average values. Reference ranges, calculated by using the robust method, were 288-324, 308-345, and 223-369 mOsm/kg in African grey parrots, Hispaniolan Amazon parrots, and red-fronted macaws, respectively. The mean +/- SD values were 306 +/- 7, 327 +/- 7, and 304 +/- 18 mOsm/kg in African grey parrots, Hispaniolan Amazon parrots, and red-fronted macaws, respectively. Comparisons with osmolality values in mammals and values previously reported for psittacine bird species suggest that plasma osmolality is slightly higher in parrots than in mammals, species-specific differences exist, and differences between reported values occur. Overall, fluids with an osmolarity close to 300-320 mOsm/L, such as Normosol-R, Plasmalyte-R, Plasmalyte-A, and NaCl 0.9%, can be recommended in parrots for fluid replacement therapy when isotonic fluids are required.
Gochicoa, Laura G; Thomé-Ortiz, Laura P; Furuya, María E Y; Canto, Raquel; Ruiz-García, Martha E; Zúñiga-Vázquez, Guillermo; Martínez-Ramírez, Filiberto; Vargas, Mario H
2012-05-01
Several studies have determined reference values for airway resistance measured by the interrupter technique (Rint) in paediatric populations, but only one has been done on Latin American children, and no studies have been performed on Mexican children. Moreover, these previous studies mostly included children aged 3 years and older; therefore, information regarding Rint reference values for newborns and infants is scarce. Rint measurements were performed on preschool children attending eight kindergartens (Group 1) and also on sedated newborns, infants and preschool children admitted to a tertiary-level paediatric hospital due to non-cardiopulmonary disorders (Group 2). In both groups, Rint values were inversely associated with age, weight and height, but the strongest association was with height. The linear regression equation for Group 1 (n = 209, height 86-129 cm) was Rint = 2.153 - 0.012 × height (cm) (standard deviation of residuals 0.181 kPa/L/s). The linear regression equation for Group 2 (n = 55, height 52-113 cm) was Rint = 4.575 - 0.035 × height (cm) (standard deviation of residuals 0.567 kPa/L/s). Girls tended to have slightly higher Rint values than boys, a difference that diminished with increasing height. In this study, Rint reference values applicable to Mexican children were determined, and these values are probably also applicable to other paediatric populations with similar Spanish-Amerindian ancestries. There was an inverse relationship between Rint and height, with relatively large between-subject variability. © 2012 The Authors. Respirology © 2012 Asian Pacific Society of Respirology.
Khan, Muhammad Khalid; Khan, Muhammad Farid; Mustafa, Ghulam; Sualah, Mohammed
2012-01-01
Ciprofloxacin was given orally to 28 healthy male volunteers for single oral dose of 500mg; Plasma samples were collected at different time's interval between 0 and 12h and analyzed both by high pressure liquid chromatography and by a microbiological assay. The detection limits (LOD) were 0.02μg/ml and 0.1μg/ml, for both methods respectively. For each method, coefficients of variation (R(2)) were 0.9995 and 0.9918 in plasma and limit of quantitation (LOQ).02 and 0.5μg/ml. The Comparison of means maximum concentration 2.68 μg/ml at 1.5 hr for test and 2.43 μg/ml are attain in HPLC method of Reference at 2hrs respectively. The plasma concentrations measured by microbiological assay of reference tablet are 3.95μg/ml (mean ± SE) at 1 hour and 3.80μg/ml (mean ± SE) at 1 hour. The concentrations in plasma measured by microbiological method were markedly higher than the high-pressure liquid chromatography values which indicates the presence of antimicrobially active metabolites. The mean ± SE values of pharmacokinetic parameters calculated by HPLC method, for total area under the curve (AUC 0-oo) were 13.11, and 11.91 h.mg/l for both test and reference tablets respectively. The mean ± SE values of clearance measured in l/h were 44.91 and 48.42 respectively. The elimination rate constant Kel [l/h] showed 0.17 l/h for test and 0.15 l/h reference tablets and likewise, absorption half-life expressed in hours shown 0.67 h for test and 1.04 h for reference respectively. The Mean Residence Time for test is 5.48 h and 5.49 h for reference. The mean ± SE values of pharmacokinetic parameters (Microbiological assay) for total area under the curve (AUC 0-oo) were 22.11 and 19.33 h.mg/l for both test and reference tablets respectively. The mean ± SE values of clearance measured in l/h were 29.02 and 31.63 respectively. The elimination rate constant Kel [l/h] showed 0.21 l/h for test and 0.20 l/h reference tablets and likewise, absorption half-life expressed in hours shown 0.86h for test and 0.56 h for reference respectively. The Mean Residence Time for test is 5.27 h and 4.67 h for reference. Significant difference observed between two methods.
How the reference values for serum parathyroid hormone concentration are (or should be) established?
Souberbielle, J-C; Brazier, F; Piketty, M-L; Cormier, C; Minisola, S; Cavalier, E
2017-03-01
Well-validated reference values are necessary for a correct interpretation of a serum PTH concentration. Establishing PTH reference values needs recruiting a large reference population. Exclusion criteria for this population can be defined as any situation possibly inducing an increase or a decrease in PTH concentration. As recommended in the recent guidelines on the diagnosis and management of asymptomatic primary hyperparathyroidism, PTH reference values should be established in vitamin D-replete subjects with a normal renal function with possible stratification according to various factors such as age, gender, menopausal status, body mass index, and race. A consensus about analytical/pre-analytical aspects of PTH measurement is also needed with special emphasis on the nature of the sample (plasma or serum), the time and the fasting/non-fasting status of the blood sample. Our opinion is that blood sample for PTH measurement should be obtained in the morning after an overnight fast. Furthermore, despite longer stability of the PTH molecule in EDTA plasma, we prefer serum as it allows to measure calcium, a prerequisite for a correct interpretation of a PTH concentration, on the same sample. Once a consensus is reached, we believe an important international multicentre work should be performed to recruit a very extensive reference population of apparently healthy vitamin D-replete subjects with a normal renal function in order to establish the PTH normative data. Due to the huge inter-method variability in PTH measurement, a sufficient quantity of blood sample should be obtained to allow measurement with as many PTH kits as possible.
Age- and sex-specific reference values of a test of neck muscle endurance.
Peolsson, Anneli; Almkvist, Cecilia; Dahlberg, Camilla; Lindqvist, Sara; Pettersson, Susanne
2007-01-01
This study evaluates age- and sex-specific reference values for neck muscle endurance (NME). In this cross-sectional study, 116 randomly selected, healthy volunteers (ages 25-64 years) stratified according to age and gender participated. Dorsal and ventral NME was measured in seconds until exhaustion in a laying-down position. A weight of 4 kg for men or 2 kg for women was used in the dorsal procedure. The ventral procedure was performed without external load. Background and physical activity data were obtained and used in the analysis of NME performance. Mean values for dorsal and ventral NME were about 7 and 2.5 minutes for men and 8.5 and 0.5 minutes for women, respectively. The cutoff values for subnormal dorsal and ventral NME were 157 and 56 seconds for men and 173 and 23 seconds for women, respectively. Women's NME was 122% of men's NME in the dorsal (P = .17) and 24% of men's NME in the ventral (P < .0001) procedure. There were no significant differences among age groups. In multiple regression analysis, physical activity explained 4% of variability in the performance of the dorsal NME; and sex explained 37% of the variability in the performance of ventral NME. The reference values and the cutoff points obtained could be used in clinical practice to identify patients with a subnormal NME. Sex is an important consideration when using both the test procedure and the reference values.
Reference values for the muscle power sprint test in 6- to 12-year-old children.
Douma-van Riet, Danielle; Verschuren, Olaf; Jelsma, Dorothee; Kruitwagen, Cas; Smits-Engelsman, Bouwien; Takken, Tim
2012-01-01
The aims of this study were (1) to develop centile reference values for anaerobic performance of Dutch children tested using the Muscle Power Sprint Test (MPST) and (2) to examine the test-retest reliability of the MPST. Children who were developing typically (178 boys and 201 girls) and aged 6 to 12 years (mean = 8.9 years) were recruited. The MPST was administered to 379 children, and test-retest reliability was examined in 47 children. MPST scores were transformed into centile curves, which were created using generalized additive models for location, scale, and shape. Height-related reference curves were created for both genders. Excellent (intraclass correlation coefficient = 0.98) test-retest reliability was demonstrated. The reference values for the MPST of children who are developing typically and aged 6 to 12 years can serve as a clinical standard in pediatric physical therapy practice. The MPST is a reliable and practical method for determining anaerobic performance in children.
Palm-Based Standard Reference Materials for Iodine Value and Slip Melting Point
Tarmizi, Azmil Haizam Ahmad; Lin, Siew Wai; Kuntom, Ainie
2008-01-01
This work described study protocols on the production of Palm-Based Standard Reference Materials for iodine value and slip melting point. Thirty-three laboratories collaborated in the inter-laboratory proficiency tests for characterization of iodine value, while thirty-two laboratories for characterization of slip melting point. The iodine value and slip melting point of palm oil, palm olein and palm stearin were determined in accordance to MPOB Test Methods p3.2:2004 and p4.2:2004, respectively. The consensus values and their uncertainties were based on the acceptability of statistical agreement of results obtained from collaborating laboratories. The consensus values and uncertainties for iodine values were 52.63 ± 0.14 Wijs in palm oil, 56.77 ± 0.12 Wijs in palm olein and 33.76 ± 0.18 Wijs in palm stearin. For the slip melting points, the consensus values and uncertainties were 35.6 ± 0.3 °C in palm oil, 22.7 ± 0.4 °C in palm olein and 53.4 ± 0.2 °C in palm stearin. Repeatability and reproducibility relative standard deviations were found to be good and acceptable, with values much lower than that of 10%. Stability of Palm-Based Standard Reference Materials remained stable at temperatures of −20 °C, 0 °C, 6 °C and 24 °C upon storage for one year. PMID:19609396
Nerve ultrasound normal values - Readjustment of the ultrasound pattern sum score UPSS.
Grimm, Alexander; Axer, Hubertus; Heiling, Bianka; Winter, Natalie
2018-07-01
Reference values are crucial for nerve ultrasound. Here, we reevaluated normal nerve and fascicle cross-sectional area (CSA) values in humans and compared them to published values. Based on these data, ultrasound pattern sum score (UPSS) boundary values were revisited and readjusted. Ultrasound of different peripheral nerves was performed in 100 healthy subjects at anatomically defined landmarks. Correlations with age, gender, height and weight were calculated. Overall, correspondence to other published reference values was high. Gender-dependency was found for the proximal median nerve. Dependency from height occurred in the tibial nerve (TN). Weight-dependency was not found. However, the most obvious differences were found in the TN between men >60 years and women <60 years. Thus, general boundary values were defined using the mean plus the twofold standard deviation for all subjects and nerve segments except for the TN, in which different cut-offs were proposed for elder men. Accordingly, the cut-offs for the UPSS were re-adjusted, none of the individuals revealed more than 2 points at maximum. The influence of distinct epidemiological factors on nerve size is most prominent in the TN, for which thus several normal values are useful. Adjusted reference values improve the accuracy of the UPSS. Copyright © 2018 International Federation of Clinical Neurophysiology. Published by Elsevier B.V. All rights reserved.
The value of cows in reference populations for genomic selection of new functional traits.
Buch, L H; Kargo, M; Berg, P; Lassen, J; Sørensen, A C
2012-06-01
Today, almost all reference populations consist of progeny tested bulls. However, older progeny tested bulls do not have reliable estimated breeding values (EBV) for new traits. Thus, to be able to select for these new traits, it is necessary to build a reference population. We used a deterministic prediction model to test the hypothesis that the value of cows in reference populations depends on the availability of phenotypic records. To test the hypothesis, we investigated different strategies of building a reference population for a new functional trait over a 10-year period. The trait was either recorded on a large scale (30 000 cows per year) or on a small scale (2000 cows per year). For large-scale recording, we compared four scenarios where the reference population consisted of 30 sires; 30 sires and 170 test bulls; 30 sires and 2000 cows; or 30 sires, 2000 cows and 170 test bulls in the first year with measurements of the new functional trait. In addition to varying the make-up of the reference population, we also varied the heritability of the trait (h2 = 0.05 v. 0.15). The results showed that a reference population of test bulls, cows and sires results in the highest accuracy of the direct genomic values (DGV) for a new functional trait, regardless of its heritability. For small-scale recording, we compared two scenarios where the reference population consisted of the 2000 cows with phenotypic records or the 30 sires of these cows in the first year with measurements of the new functional trait. The results showed that a reference population of cows results in the highest accuracy of the DGV whether the heritability is 0.05 or 0.15, because variation is lost when phenotypic data on cows are summarized in EBV of their sires. The main conclusions from this study are: (i) the fewer phenotypic records, the larger effect of including cows in the reference population; (ii) for small-scale recording, the accuracy of the DGV will continue to increase for several years, whereas the increases in the accuracy of the DGV quickly decrease with large-scale recording; (iii) it is possible to achieve accuracies of the DGV that enable selection for new functional traits recorded on a large scale within 3 years from commencement of recording; and (iv) a higher heritability benefits a reference population of cows more than a reference population of bulls.
Schimmelmann, Arndt; Albertino, Andrea; Sauer, Peter E; Qi, Haiping; Molinie, Roland; Mesnard, François
2009-11-01
Accurate determinations of stable isotope ratios require a calibration using at least two reference materials with different isotopic compositions to anchor the isotopic scale and compensate for differences in machine slope. Ideally, the delta values of these reference materials should bracket the isotopic range of samples with unknown delta values. While the practice of analyzing two isotopically distinct reference materials is common for water (VSMOW-SLAP) and carbonates (NBS 19 and L-SVEC), the lack of widely available organic reference materials with distinct isotopic composition has hindered the practice when analyzing organic materials by elemental analysis/isotope ratio mass spectrometry (EA-IRMS). At present only L-glutamic acids USGS40 and USGS41 satisfy these requirements for delta13C and delta15N, with the limitation that L-glutamic acid is not suitable for analysis by gas chromatography (GC). We describe the development and quality testing of (i) four nicotine laboratory reference materials for on-line (i.e. continuous flow) hydrogen reductive gas chromatography-isotope ratio mass-spectrometry (GC-IRMS), (ii) five nicotines for oxidative C, N gas chromatography-combustion-isotope ratio mass-spectrometry (GC-C-IRMS, or GC-IRMS), and (iii) also three acetanilide and three urea reference materials for on-line oxidative EA-IRMS for C and N. Isotopic off-line calibration against international stable isotope measurement standards at Indiana University adhered to the 'principle of identical treatment'. The new reference materials cover the following isotopic ranges: delta2H(nicotine) -162 to -45 per thousand, delta13C(nicotine) -30.05 to +7.72 per thousand, delta15N(nicotine) -6.03 to +33.62 per thousand; delta15N(acetanilide) +1.18 to +40.57 per thousand; delta13C(urea) -34.13 to +11.71 per thousand, delta15N(urea) +0.26 to +40.61 per thousand (recommended delta values refer to calibration with NBS 19, L-SVEC, IAEA-N-1, and IAEA-N-2). Nicotines fill a gap as the first organic nitrogen stable isotope reference materials for GC-IRMS that are available with different delta15N values. Comparative delta13C and delta15N on-line EA-IRMS data from 14 volunteering laboratories document the usefulness and reliability of acetanilides and ureas as EA-IRMS reference materials. Copyright 2009 John Wiley & Sons, Ltd.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hamlet, Jason R.; Mayo, Jackson R.
Embodiments of the invention describe a Boolean circuit having a voter circuit and a plurality of approximate circuits each based, at least in part, on a reference circuit. The approximate circuits are each to generate one or more output signals based on values of received input signals. The voter circuit is to receive the one or more output signals generated by each of the approximate circuits, and is to output one or more signals corresponding to a majority value of the received signals. At least some of the approximate circuits are to generate an output value different than the referencemore » circuit for one or more input signal values; however, for each possible input signal value, the majority values of the one or more output signals generated by the approximate circuits and received by the voter circuit correspond to output signal result values of the reference circuit.« less
Takei, Izumi; Hoshino, Tadao; Tominaga, Makoto; Ishibashi, Midori; Kuwa, Katsuhiko; Umemoto, Masao; Tani, Wataru; Okahashi, Mikiko; Yasukawa, Keiko; Kohzuma, Takuji; Sato, Asako
2016-01-01
Glycated albumin is an intermediate glycaemic control marker for which there are several measurement procedures with entirely different reference intervals. We have developed a reference measurement procedure for the purpose of standardizing glycated albumin measurements. The isotope dilution liquid chromatography/tandem mass spectrometry method was developed as a reference measurement procedure for glycated albumin. The stable isotopes of lysine and fructosyl-lysine, which serve as an internal standard, were added to albumin isolated from serum, followed by hydrogenation. After hydrolysis of albumin with hot hydrochloric acid, the liberated lysine and fructosyl-lysine were measured by liquid chromatography/tandem mass spectrometry, and their concentrations were determined from each isotope ratio. The reference materials (JCCRM611) for determining of glycated albumin were prepared from pooled patient blood samples. The isotope dilution-tandem mass spectrometry calibration curve of fructosyl-lysine and lysine showed good linearity (r = 0.999). The inter-assay and intra-assay coefficient of variation values of glycated albumin measurement were 1.2 and 1.4%, respectively. The glycated albumin values of serum in patients with diabetes assessed through the use of this method showed a good relationship with routine measurement procedures (r = 0.997). The relationship of glycated albumin values of the reference material (JCCRM611) between these two methods was the same as the relationship with the patient serum samples. The Committee on Diabetes Mellitus Indices of the Japan Society of Clinical Chemistry recommends the isotope dilution liquid chromatography/tandem mass spectrometry method as a reference measurement procedure, and JCCRM611 as a certified reference material for glycated albumin measurement. In addition, we recommend the traceability system for glycated albumin measurement. © The Author(s) 2015.
Lee, Won-Jae; Jeon, Ryoung-Hoon; Jang, Si-Jung; Park, Ji-Sung; Lee, Seung-Chan; Baregundi Subbarao, Raghavendra; Lee, Sung-Lim; Park, Bong-Wook; King, William Allan; Rho, Gyu-Jin
2015-01-01
The identification of stable reference genes is a prerequisite for ensuring accurate validation of gene expression, yet too little is known about stable reference genes of porcine MSCs. The present study was, therefore, conducted to assess the stability of reference genes in porcine MSCs derived from bone marrow (BMSCs), adipose (AMSCs), and skin (SMSCs) with their in vitro differentiated cells into mesenchymal lineages such as adipocytes, osteocytes, and chondrocytes. Twelve commonly used reference genes were investigated for their threshold cycle (Ct) values by qRT-PCR. The Ct values of candidate reference genes were analyzed by geNorm software to clarify stable expression regardless of experimental conditions. Thus, Pearson's correlation was applied to determine correlation between the three most stable reference genes (NF3) and optimal number of reference genes (NFopt). In assessment of stability of reference gene across experimental conditions by geNorm analysis, undifferentiated MSCs and each differentiated status into mesenchymal lineages showed slightly different results but similar patterns about more or less stable rankings. Furthermore, Pearson's correlation revealed high correlation (r > 0.9) between NF3 and NFopt. Overall, the present study showed that HMBS, YWHAZ, SDHA, and TBP are suitable reference genes for qRT-PCR in porcine MSCs. PMID:25972899
Kouzakova, Marina; Ellemers, Naomi; Harinck, Fieke; Scheepers, Daan
2012-06-01
This article presents two studies demonstrating the implications of having different values (vs. interests) in a situation where people take opposite positions. Study 1 examined how people respond to a range of conflict issues that were framed either as referring to conflicting values or as referring to conflicting interests. Study 2 used a more immersive methodology, in which participants were led to consider either their values or interests in taking up a particular position, after which they were presented with a confederate who took up the opposite position. Results of both studies converge to demonstrate that framing a particular conflict issue in terms of values causes people to experience more self-involvement and to perceive less common ground. This result can be seen as a potential explanation of why value conflicts tend to escalate more easily than conflicts of interests and also offers scope for interventions directed at value conflict resolution.
Sánchez-Montoya, María del Mar; Arce, Maria Isabel; Vidal-Abarca, María Rosario; Suárez, María Luisa; Prat, Narcís; Gómez, Rosa
2012-05-01
Type-specific physico-chemical reference conditions are required for the assessment of ecological status in the Water Framework Directive context, similarly to the biological and hydro-morphological elements. This directive emphasises that natural variability of quality elements in high status (reference condition) needs to be quantified. Mediterranean streams often present a marked seasonal pattern in hydrological, biological and geochemical processes which could affect physico-chemical reference conditions. This study establishes general physico-chemical reference conditions (oxygenation, nutrient, salinity and acidification conditions) for different Mediterranean stream types. 116 potential reference sites located in 23 Mediterranean catchments in Spain were sampled in spring, summer and autumn in 2003. All sites were subjected to a screening method for the selection of reference sites in Mediterranean streams (Mediterranean Reference Criteria) and classified using a pre-established stream typology that establishes five different stream types (temporary streams, evaporite-calcareous at medium altitude, siliceous headwaters, calcareous headwaters and large watercourses). Reference conditions (reference value and reference threshold equivalents to high-good class boundary) were calculated using two different methods according to the availability of reference sites: the reference site 75th percentile approach of all reference sites and the 25th percentile of the population approach. The majority of the studied potential reference sites (76 out of 116) were selected as reference sites. Regarding type-specific reference conditions, only siliceous headwaters could be considered different from the rest of stream types because lower conductivity and pH. All reference stream types presented seasonal differences as regards some parameters, except for temporary streams due to the high natural variation of this stream type. For those parameters which presented seasonal differences in a specific stream type, the least restrictive values were proposed as reference conditions. Copyright © 2012 Elsevier Ltd. All rights reserved.
Method and apparatus for monitoring oxygen partial pressure in air masks
NASA Technical Reports Server (NTRS)
Kelly, Mark E. (Inventor); Pettit, Donald R. (Inventor)
2006-01-01
Method and apparatus are disclosed for monitoring an oxygen partial pressure in an air mask and providing a tactile warning to the user. The oxygen partial pressure in the air mask is detected using an electrochemical sensor, the output signal from which is provided to a comparator. The comparator compares the output signal with a preset reference value or range of values representing acceptable oxygen partial pressures. If the output signal is different than the reference value or outside the range of values, the air mask is vibrated by a vibrating motor to alert the user to a potentially hypoxic condition.
Schantz, Michele M; Benner, Bruce A; Heckert, N Alan; Sander, Lane C; Sharpless, Katherine E; Vander Pol, Stacy S; Vasquez, Y; Villegas, M; Wise, Stephen A; Alwis, K Udeni; Blount, Benjamin C; Calafat, Antonia M; Li, Zheng; Silva, Manori J; Ye, Xiaoyun; Gaudreau, Éric; Patterson, Donald G; Sjödin, Andreas
2015-04-01
Two new Standard Reference Materials (SRMs), SRM 3672 Organic Contaminants in Smokers' Urine (Frozen) and SRM 3673 Organic Contaminants in Non-Smokers' Urine (Frozen), have been developed in support of studies for assessment of human exposure to select organic environmental contaminants. Collaborations among three organizations resulted in certified values for 11 hydroxylated polycyclic aromatic hydrocarbons (OH-PAHs) and reference values for 11 phthalate metabolites, 8 environmental phenols and parabens, and 24 volatile organic compound (VOC) metabolites. Reference values are also available for creatinine and the free forms of caffeine, theobromine, ibuprofen, nicotine, cotinine, and 3-hydroxycotinine. These are the first urine Certified Reference Materials characterized for metabolites of organic environmental contaminants. Noteworthy, the mass fractions of the environmental organic contaminants in the two SRMs are within the ranges reported in population survey studies such as the National Health and Nutrition Examination Survey (NHANES) and the Canadian Health Measures Survey (CHMS). These SRMs will be useful as quality control samples for ensuring compatibility of results among population survey studies and will fill a void to assess the accuracy of analytical methods used in studies monitoring human exposure to these organic environmental contaminants.
Schantz, Michele M.; Benner, Bruce A.; Heckert, N. Alan; Sander, Lane C.; Sharpless, Katherine E.; Vander Pol, Stacy S.; Vasquez, Y.; Villegas, M.; Wise, Stephen A.; Alwis, K. Udeni; Blount, Benjamin C.; Calafat, Antonia M.; Li, Zheng; Silva, Manori J.; Ye, Xiaoyun; Gaudreau, Éric; Patterson, Donald G.; Sjödin, Andreas
2016-01-01
Two new Standard Reference Materials (SRMs), SRM 3672 Organic Contaminants in Smokers’ Urine (Frozen) and SRM 3673 Organic Contaminants in Non-Smokers’ Urine (Frozen), have been developed in support of studies for assessment of human exposure to select organic environmental contaminants. Collaborations among three organizations resulted in certified values for 11 hydroxylated polycyclic aromatic hydrocarbons (OH-PAHs) and reference values for 11 phthalate metabolites, 8 environmental phenols and parabens, and 24 volatile organic compound (VOC) metabolites. Reference values are also available for creatinine and the free forms of caffeine, theobromine, ibuprofen, nicotine, cotinine, and 3-hydroxycotinine. These are the first urine Certified Reference Materials characterized for metabolites of organic environmental contaminants. Noteworthy, the mass fractions of the environmental organic contaminants in the two SRMs are within the ranges reported in population survey studies such as the National Health and Nutrition Examination Survey (NHANES) and the Canadian Health Measures Survey (CHMS). These SRMs will be useful as quality control samples for ensuring compatibility of results among population survey studies and will fill a void to assess the accuracy of analytical methods used in studies monitoring human exposure to these organic environmental contaminants. PMID:25651899
Leers, M P G; Keuren, J F W; Oosterhuis, W P
2010-12-01
In patients with inflammatory conditions, diagnosing classic iron deficiency or anemia of chronic disease is challenging. In this study, we assessed the diagnostic value of the so-called Thomas'-plot [soluble transferrin receptor (sTfR)/log ferritin (sTfr/log Ferr) and the reticulocyte hemoglobin equivalent (Ret-HE)] in the anemia work up of patients referred by general practitioners. During July 2008-March 2009, 337 consecutive patients were included because of lowered Hb values. The laboratory results of the first 133 consecutive patients were used to determine the cut-off values for the diagnostic plot. The laboratory results of these patients were assessed and interpreted independently by two investigators, blinded from sTfR/log Ferr and Ret-HE values. The following 204 patients were used to test the plot in practice. In 32% of the first 133 patients, no indication of the cause of anemia could be found. However, when using the diagnostic plot in the following 204 patients, this fraction decreased to 14%. The 'Thomas'-plot is of diagnostic value for distinguishing functional iron deficiency from classic iron deficiency in a patient population referred by general practitioners. © 2010 Blackwell Publishing Ltd.
Assessment of the Accuracy of the Bethe-Salpeter (BSE/GW) Oscillator Strengths.
Jacquemin, Denis; Duchemin, Ivan; Blondel, Aymeric; Blase, Xavier
2016-08-09
Aiming to assess the accuracy of the oscillator strengths determined at the BSE/GW level, we performed benchmark calculations using three complementary sets of molecules. In the first, we considered ∼80 states in Thiel's set of compounds and compared the BSE/GW oscillator strengths to recently determined ADC(3/2) and CC3 reference values. The second set includes the oscillator strengths of the low-lying states of 80 medium to large dyes for which we have determined CC2/aug-cc-pVTZ values. The third set contains 30 anthraquinones for which experimental oscillator strengths are available. We find that BSE/GW accurately reproduces the trends for all series with excellent correlation coefficients to the benchmark data and generally very small errors. Indeed, for Thiel's sets, the BSE/GW values are more accurate (using CC3 references) than both CC2 and ADC(3/2) values on both absolute and relative scales. For all three sets, BSE/GW errors also tend to be nicely spread with almost equal numbers of positive and negative deviations as compared to reference values.
Integrative missing value estimation for microarray data.
Hu, Jianjun; Li, Haifeng; Waterman, Michael S; Zhou, Xianghong Jasmine
2006-10-12
Missing value estimation is an important preprocessing step in microarray analysis. Although several methods have been developed to solve this problem, their performance is unsatisfactory for datasets with high rates of missing data, high measurement noise, or limited numbers of samples. In fact, more than 80% of the time-series datasets in Stanford Microarray Database contain less than eight samples. We present the integrative Missing Value Estimation method (iMISS) by incorporating information from multiple reference microarray datasets to improve missing value estimation. For each gene with missing data, we derive a consistent neighbor-gene list by taking reference data sets into consideration. To determine whether the given reference data sets are sufficiently informative for integration, we use a submatrix imputation approach. Our experiments showed that iMISS can significantly and consistently improve the accuracy of the state-of-the-art Local Least Square (LLS) imputation algorithm by up to 15% improvement in our benchmark tests. We demonstrated that the order-statistics-based integrative imputation algorithms can achieve significant improvements over the state-of-the-art missing value estimation approaches such as LLS and is especially good for imputing microarray datasets with a limited number of samples, high rates of missing data, or very noisy measurements. With the rapid accumulation of microarray datasets, the performance of our approach can be further improved by incorporating larger and more appropriate reference datasets.
Estimating clinical chemistry reference values based on an existing data set of unselected animals.
Dimauro, Corrado; Bonelli, Piero; Nicolussi, Paola; Rassu, Salvatore P G; Cappio-Borlino, Aldo; Pulina, Giuseppe
2008-11-01
In an attempt to standardise the determination of biological reference values, the International Federation of Clinical Chemistry (IFCC) has published a series of recommendations on developing reference intervals. The IFCC recommends the use of an a priori sampling of at least 120 healthy individuals. However, such a high number of samples and laboratory analysis is expensive, time-consuming and not always feasible, especially in veterinary medicine. In this paper, an alternative (a posteriori) method is described and is used to determine reference intervals for biochemical parameters of farm animals using an existing laboratory data set. The method used was based on the detection and removal of outliers to obtain a large sample of animals likely to be healthy from the existing data set. This allowed the estimation of reliable reference intervals for biochemical parameters in Sarda dairy sheep. This method may also be useful for the determination of reference intervals for different species, ages and gender.
Zhi, Ruicong; Zhao, Lei; Xie, Nan; Wang, Houyin; Shi, Bolin; Shi, Jingye
2016-01-13
A framework of establishing standard reference scale (texture) is proposed by multivariate statistical analysis according to instrumental measurement and sensory evaluation. Multivariate statistical analysis is conducted to rapidly select typical reference samples with characteristics of universality, representativeness, stability, substitutability, and traceability. The reasonableness of the framework method is verified by establishing standard reference scale of texture attribute (hardness) with Chinese well-known food. More than 100 food products in 16 categories were tested using instrumental measurement (TPA test), and the result was analyzed with clustering analysis, principal component analysis, relative standard deviation, and analysis of variance. As a result, nine kinds of foods were determined to construct the hardness standard reference scale. The results indicate that the regression coefficient between the estimated sensory value and the instrumentally measured value is significant (R(2) = 0.9765), which fits well with Stevens's theory. The research provides reliable a theoretical basis and practical guide for quantitative standard reference scale establishment on food texture characteristics.
Automatic dynamic range adjustment for ultrasound B-mode imaging.
Lee, Yeonhwa; Kang, Jinbum; Yoo, Yangmo
2015-02-01
In medical ultrasound imaging, dynamic range (DR) is defined as the difference between the maximum and minimum values of the displayed signal to display and it is one of the most essential parameters that determine its image quality. Typically, DR is given with a fixed value and adjusted manually by operators, which leads to low clinical productivity and high user dependency. Furthermore, in 3D ultrasound imaging, DR values are unable to be adjusted during 3D data acquisition. A histogram matching method, which equalizes the histogram of an input image based on that from a reference image, can be applied to determine the DR value. However, it could be lead to an over contrasted image. In this paper, a new Automatic Dynamic Range Adjustment (ADRA) method is presented that adaptively adjusts the DR value by manipulating input images similar to a reference image. The proposed ADRA method uses the distance ratio between the log average and each extreme value of a reference image. To evaluate the performance of the ADRA method, the similarity between the reference and input images was measured by computing a correlation coefficient (CC). In in vivo experiments, the CC values were increased by applying the ADRA method from 0.6872 to 0.9870 and from 0.9274 to 0.9939 for kidney and liver data, respectively, compared to the fixed DR case. In addition, the proposed ADRA method showed to outperform the histogram matching method with in vivo liver and kidney data. When using 3D abdominal data with 70 frames, while the CC value from the ADRA method is slightly increased (i.e., 0.6%), the proposed method showed improved image quality in the c-plane compared to its fixed counterpart, which suffered from a shadow artifact. These results indicate that the proposed method can enhance image quality in 2D and 3D ultrasound B-mode imaging by improving the similarity between the reference and input images while eliminating unnecessary manual interaction by the user. Copyright © 2014 Elsevier B.V. All rights reserved.
Miller, Donald L.; Kwon, Deukwoo; Bonavia, Grant H.
2009-01-01
Purpose: To propose initial values for patient reference levels for fluoroscopically guided procedures in the United States. Materials and Methods: This secondary analysis of data from the Radiation Doses in Interventional Radiology Procedures (RAD-IR) study was conducted under a protocol approved by the institutional review board and was HIPAA compliant. Dose distributions (percentiles) were calculated for each type of procedure in the RAD-IR study where there were data from at least 30 cases. Confidence intervals for the dose distributions were determined by using bootstrap resampling. Weight banding and size correction methods for normalizing dose to patient body habitus were tested. Results: The different methods for normalizing patient radiation dose according to patient weight gave results that were not significantly different (P > .05). The 75th percentile patient radiation doses normalized with weight banding were not significantly different from those that were uncorrected for body habitus. Proposed initial reference levels for various interventional procedures are provided for reference air kerma, kerma-area product, fluoroscopy time, and number of images. Conclusion: Sufficient data exist to permit an initial proposal of values for reference levels for interventional radiologic procedures in the United States. For ease of use, reference levels without correction for body habitus are recommended. A national registry of radiation-dose data for interventional radiologic procedures is a necessary next step to refine these reference levels. © RSNA, 2009 Supplemental material: http://radiology.rsna.org/lookup/suppl/doi:10.1148/radiol.2533090354/-/DC1 PMID:19789226
Plasma chemistry references values in psittaciformes.
Lumeij, J T; Overduin, L M
1990-04-01
Reference values for 17 plasma chemical variables in African greys. Amazons, cockatoos and macaws were established for use in avian clinical practice. The inner limits are given for the percentiles P(2.5) and P(97.5) with a probability of 90%. The following variables were studied: urea, creatinine, uric acid, urea/uric acid ratio, osmolality, sodium, potassium, calcium, glucose, aspartate aminotransferase, alanine aminotransferase, gamma glutamyltransferase, lactate dehydrogenase, creatine kinase, bile acids, total protein, albumin/globulin ratio. Differences between methods used and values found in this study and those reported previously are discussed.
Choice by value encoding and value construction: processes of loss aversion.
Willemsen, Martijn C; Böckenholt, Ulf; Johnson, Eric J
2011-08-01
Loss aversion and reference dependence are 2 keystones of behavioral theories of choice, but little is known about their underlying cognitive processes. We suggest an additional account for loss aversion that supplements the current account of the value encoding of attributes as gains or losses relative to a reference point, introducing a value construction account. Value construction suggests that loss aversion results from biased evaluations during information search and comparison processes. We develop hypotheses that identify the influence of both accounts and examine process-tracing data for evidence. Our data suggest that loss aversion is the result of the initial direct encoding of losses that leads to the subsequent process of directional comparisons distorting attribute valuations and the final choice.
ESTABLISHMENT OF A FIBRINOGEN REFERENCE INTERVAL IN ORNATE BOX TURTLES (TERRAPENE ORNATA ORNATA).
Parkinson, Lily; Olea-Popelka, Francisco; Klaphake, Eric; Dadone, Liza; Johnston, Matthew
2016-09-01
This study sought to establish a reference interval for fibrinogen in healthy ornate box turtles ( Terrapene ornata ornata). A total of 48 turtles were enrolled, with 42 turtles deemed to be noninflammatory and thus fitting the inclusion criteria and utilized to estimate a fibrinogen reference interval. Turtles were excluded based upon physical examination and blood work abnormalities. A Shapiro-Wilk normality test indicated that the noninflammatory turtle fibrinogen values were normally distributed (Gaussian distribution) with an average of 108 mg/dl and a 95% confidence interval of the mean of 97.9-117 mg/dl. Those turtles excluded from the reference interval because of abnormalities affecting their health had significantly different fibrinogen values (P = 0.313). A reference interval for healthy ornate box turtles was calculated. Further investigation into the utility of fibrinogen measurement for clinical usage in ornate box turtles is warranted.
ERIC Educational Resources Information Center
Verschuren, Olaf; Bloemen, Manon; Kruitwagen, Cas; Takken, Tim
2010-01-01
Aim: The aim of this study was to provide reference values of anaerobic performance and agility in a group of children and adolescents with spastic cerebral palsy (CP). Method: A total of 300 children (184 males, 116 females) with spastic CP were recruited from 26 rehabilitation centres in six different countries. Of these, 215 were classified at…
Petrosino, V; Motta, G; Tenore, G; Coletta, M; Guariglia, A; Testa, D
2018-04-01
Previous literature has highlighted the mechanisms of molecular toxicity induced by substances such as arsenic, cadmium, chromium, nickel, lead, barium and PCBs. The research was carried out on 20 volunteers, all the patients gave their consent to the research: the aim of the study was to evaluate the presence of metals and PCBs in these different matrices (blood and hair), correlating the biochemical data to pathological conditions present, and also to the area in which patients resided. Various quantitative determinations were carried out on samples of blood and hair for 14 heavy metals and on blood samples for 12 PCBs. For the 11 patients the results indicated that blood levels for half of the 14 displayed heavy metals measured considerably higher compared to the reference values, whilst the levels measured in hair evidenced some positive values significantly higher than the maximum reference. Of the 12 PCBs assayed in blood some showed higher positive values compared to the maximum tabular reference (although there is no clear reference quantified in the WHO-2005 report). In the 9 healthy patients heavy metals in the blood were within the expected target range, with those showing positive results (≤ 3 out of 14 heavy metals for each patient) having values only slightly higher than the reference maximum. The levels of 14 heavy metals measured in hair were below thresholds, and levels for the 12 PCBs measured in blood showed negativity or positivity with values close to the minimum benchmarks. The analyses carried out on biological matrices have uncovered important and significant differences between healthy and unhealthy subjects, both qualitative and quantitative differences with respect to heavy metals and PCBs. All patients with head and neck cancer enlisted for the study had heavy metal and PCB blood levels at least twice the maximum reference level. The levels of heavy metals in hair were at least double the maximum reference. In contrast, all healthy volunteers enrolled showed no significant levels for either metals or PCBs.
Miri-Dashe, Timzing; Osawe, Sophia; Tokdung, Monday; Daniel, Monday Tokdung Nenbammun; Daniel, Nenbammun; Choji, Rahila Pam; Mamman, Ille; Deme, Kurt; Damulak, Dapus; Abimiku, Alash'le
2014-01-01
Interpretation of laboratory test results with appropriate diagnostic accuracy requires reference or cutoff values. This study is a comprehensive determination of reference values for hematology and clinical chemistry in apparently healthy voluntary non-remunerated blood donors and pregnant women. Consented clients were clinically screened and counseled before testing for HIV, Hepatitis B, Hepatitis C and Syphilis. Standard national blood donors' questionnaire was administered to consented blood donors. Blood from qualified volunteers was used for measurement of complete hematology and chemistry parameters. Blood samples were analyzed from a total of 383 participants, 124 (32.4%) males, 125 (32.6%) non-pregnant females and 134 pregnant females (35.2%) with a mean age of 31 years. Our results showed that the red blood cells count (RBC), Hemoglobin (HB) and Hematocrit (HCT) had significant gender difference (p = 0.000) but not for total white blood count (p>0.05) which was only significantly higher in pregnant verses non-pregnant women (p = 0.000). Hemoglobin and Hematocrit values were lower in pregnancy (P = 0.000). Platelets were significantly higher in females than men (p = 0.001) but lower in pregnant women (p = .001) with marked difference in gestational period. For clinical chemistry parameters, there was no significant difference for sodium, potassium and chloride (p>0.05) but gender difference exists for Bicarbonate (HCO3), Urea nitrogen, Creatinine as well as the lipids (p<0.05). Total bilirubin was significantly higher in males than females (p = 0.000). Significant differences exist for all chemistry parameters between pregnant and non-pregnant women in this study (p<0.05), except Amylase and total cholesterol (p>0.05). Hematological and Clinical Chemistry reference ranges established in this study showed significant gender differences. Pregnant women also differed from non-pregnant females and during pregnancy. This is the first of such comprehensive study to establish reference values among adult Nigerians and difference observed underscore the need to establish reference values for different populations.
Snyder Valier, Alison R; Welch Bacon, Cailee E; Bay, R Curtis; Molzen, Eileen; Lam, Kenneth C; Valovich McLeod, Tamara C
2017-10-01
Effective use of patient-rated outcome measures to facilitate optimal patient care requires an understanding of the reference values of these measures within the population of interest. Little is known about reference values for commonly used patient-rated outcome measures in adolescent athletes. To determine reference values for the Pediatric Quality of Life Inventory (PedsQL) and the Multidimensional Fatigue Scale (MFS) in adolescent athletes by sport and sex. Cross-sectional study; Level of evidence, 3. A convenience sample of interscholastic adolescent athletes from 9 sports was used. Participants completed the PedsQL and MFS during one testing session at the start of their sport season. Data were stratified by sport and sex. Dependent variables included the total PedsQL score and the 5 PedsQL subscale scores: physical functioning, psychosocial functioning, emotional functioning, social functioning, and school functioning. Dependent variables for the MFS included 3 subscale scores: general functioning, sleep functioning, and cognitive functioning. Summary statistics were reported for total and subscale scores by sport and sex. Among 3574 males and 1329 female adolescent athletes, the PedsQL scores (100 possible points) generally indicated high levels of health regardless of sport played. Mean PedsQL total and subscales scores ranged from 82.6 to 95.7 for males and 83.9 to 95.2 for females. Mean MFS subscale scores (100 possible points) ranged from 74.2 to 90.9 for males and 72.8 to 87.4 for females. Healthy male and female adolescent athletes reported relatively high levels of health on the PedsQL subscales and total scores regardless of sport; no mean scores were lower than 82.6 points for males or 83.9 points for females. On the MFS, males and females tended to report low effect of general and cognitive fatigue regardless of sport; mean scores were higher than 83.5 points for males and 83.8 points for females. Clinically, athletes who score below the reference values for their sport have poorer health status than average adolescent athletes participating in that sport. Scores below reference values may warrant consideration of early intervention or treatment.
Bushland Reference ET Calculator with QA/QC capabilities and iPhone/iPad application
USDA-ARS?s Scientific Manuscript database
Accurate daily reference evapotranspiration (ET) values are needed to estimate crop water demand for irrigation management and hydrologic modeling purposes. The USDA-ARS Conservation and Production Research Laboratory at Bushland, Texas developed the Bushland Reference ET (BET) Calculator for calcul...
Gawlik, B M; Lamberty, A; Pauwels, J; Blum, W E H; Mentler, A; Bussian, B; Eklo, O; Fox, K; Kördel, W; Hennecke, D; Maurer, T; Perrin-Ganier, C; Romero-Taboada, E; Szabo, G; Muntau, H
2003-08-01
IRMM-443 re-groups a set of six European Reference Soils (EUROSOILS), which had been certified for their adsorption coefficients for atrazine, 2,4-D and lindane (Certification of the European Reference Soil Set (IRMM-443-EUROSOILS)-Part I. Adsorption coefficients for atrazine, 2,4-D and lindane. Sci Total Environ, in press). The certification of these parameters was complemented by an additional certification of pH in suspension as well by the determination of indicative values for total nitrogen, organic and total carbon content. While Part I explained the principles of the value assignment process and discussed their application to the adsorption coefficients, Part II presents the certified values for pH as well as the indicative values for N(tot), C(tot) and C(org). In addition, the assessment of uncertainty components for stability and homogeneity, which have been included in the final uncertainty budget, is discussed.
Rogers, Linda B; Kaack, M Bernice; Henson, Michael C; Rasmussen, Terri; Henson, Elizabeth; Veazey, Ronald S; Krogstad, Donald J; Davison, Billie B
2005-06-01
Hematology and flow cytometry reference values for rhesus umbilical cord blood (UCB) were established in 17 healthy infant rhesus monkeys delivered by elective cesarean section 10 days preterm. The infants were born to age matched, singly caged primigravid or secundigravid dams. The hematology and flow cytometry values were determined by automated cell counter and by FACS. No significant differences were observed with respect to infant gender. With respect to gravida, the primigravid infants had a significantly higher percentage (P= 0.05) of CD20(+) B lymphocytes in UCB. These results provide useful reference values for future studies of maternal - fetal disease transmission, vaccine and drug evaluation in non-human primate pregnancy, as well as fetal programming and immune modulation, gene therapy and the use of UCB as a source of stem cells for research and transplantation. Importantly, our results suggest that maternal gravidity may be an important variable to consider.
Hartlage, Gregory R; Kim, Jonathan H; Strickland, Patrick T; Cheng, Alan C; Ghasemzadeh, Nima; Pernetz, Maria A; Clements, Stephen D; Williams, B Robinson
2015-03-01
Speckle-tracking left ventricular global longitudinal strain (GLS) assessment may provide substantial prognostic information for hypertrophic cardiomyopathy (HCM) patients. Reference values for GLS have been recently published. We aimed to evaluate the prognostic value of standardized reference values for GLS in HCM patients. An analysis of HCM clinic patients who underwent GLS was performed. GLS was defined as normal (more negative or equal to -16%) and abnormal (less negative than -16%) based on recently published reference values. Patients were followed for a composite of events including heart failure hospitalization, sustained ventricular arrhythmia, and all-cause death. The power of GLS to predict outcomes was assessed relative to traditional clinical and echocardiographic variables present in HCM. 79 HCM patients were followed for a median of 22 months (interquartile range 9-30 months) after imaging. During follow-up, 15 patients (19%) met the primary outcome. Abnormal GLS was the only echocardiographic variable independently predictive of the primary outcome [multivariate Hazard ratio 5.05 (95% confidence interval 1.09-23.4, p = 0.038)]. When combined with traditional clinical variables, abnormal GLS remained independently predictive of the primary outcome [multivariate Hazard ratio 5.31 (95 % confidence interval 1.18-24, p = 0.030)]. In a model including the strongest clinical and echocardiographic predictors of the primary outcome, abnormal GLS demonstrated significant incremental benefit for risk stratification [net reclassification improvement 0.75 (95 % confidence interval 0.21-1.23, p < 0.0001)]. Abnormal GLS is an independent predictor of adverse outcomes in HCM patients. Standardized use of GLS may provide significant incremental value over traditional variables for risk stratification.
Tveter, Anne Therese; Dagfinrud, Hanne; Moseng, Tuva; Holm, Inger
2014-07-01
To provide reference values and reference equations for frequently used clinical field tests of health-related physical fitness for use in clinical practice. Cross-sectional design. General community. Convenience sample of volunteers (N=370) between 18 and 90 years of age were recruited from a wide range of settings (ie, work sites, schools, community centers for older adults) and different geographic locations (ie, urban, suburban, rural) in southeastern Norway. Not applicable. The participants conducted 5 clinical field tests (6-minute walk test, stair test, 30-second sit-to-stand test, handgrip test, fingertip-to-floor test). The results of the field tests showed that performance remained unchanged until approximately 50 years of age; after that, performance deteriorated with increasing age. Grip strength (79%), meters walked in 6 minutes (60%), and seconds used on the stair test (59%) could be well predicted by age, sex, height, and weight in participants ≥50 years of age, whereas the performance on all tests was less well predicted in participants <50 years of age. The reference values and reference equations provided in this study may increase the applicability and interpretability of the 6-minute walk test, stair test, 30-second sit-to-stand test, handgrip test, and fingertip-to-floor test in clinical practice. Copyright © 2014 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.
Peart, D.B.; Antweiler, Ronald C.; Taylor, Howard E.; Roth, D.A.; Brinton, T.I.
1998-01-01
More than 100 US Geological Survey (USGS) Standard Reference Water Samples (SRWSs) were analyzed for numerous trace constituents, including Al, As, B, Ba, Be, Bi, Br, Cd, Cr, Co, Cu, I, Fe, Pb, Li, Mn, Mo, Ni, Rb, Sb, Se, Sr, Te, Tl, U, V, Zn and major elements (Ca, Mg, Na, SiO2, SO4, Cl) by inductively coupled plasma mass spectrometry and inductively coupled plasma atomic emission spectrometry. In addition, 15 USGS SRWSs and National Institute of Standards and Technology (NIST) standard reference material (SRM) 1641b were analyzed for mercury using cold vapor atomic fluorescence spectrometry. Also USGS SRWS Hg-7 was analyzed using isotope dilution-inductively coupled plasma mass spectrometry. The results were compared with the reported certified values of the following standard reference materials: NIST SRM 1643a, 1643b, 1643c and 1643d and National Research Council of Canada Riverine Water Reference Materials for Trace Metals SLRS-1, SLRS-2 and SLRS-3. New concentration values for trace and major elements in the SRWSs, traceable to the certified standards, are reported. Additional concentration values are reported for elements that were neither previously published for the SRWSs nor traceable to the certified reference materials. Robust statistical procedures were used that were insensitive to outliers. These data can be used for quality assurance/quality control purposes in analytical laboratories.
de Assis Pereira Cacau, Lucas; Carvalho, Vitor Oliveira; Dos Santos Pin, Alessandro; Araujo Daniel, Carlos Raphael; Ykeda, Daisy Satomi; de Carvalho, Eliane Maria; Francica, Juliana Valente; Faria, Luíza Martins; Gomes-Neto, Mansueto; Fernandes, Marcelo; Velloso, Marcelo; Karsten, Marlus; de Sá Barros, Patrícia; de Santana-Filho, Valter Joviniano
2018-03-01
Brazil is a country with great climatic, socioeconomic, and cultural differences that does not yet have a reference value for the 6-min walk test (6MWT) in healthy children. To avoid misinterpretation, the use of equations to predict the maximum walk distance should be established in each country. We sought to establish reference values and to develop an equation to predict the 6-min walk distance for healthy children in Brazil. This is a cross-sectional multi-center study that included 1,496 healthy children, aged 7 to 12 y, assessed across 11 research sites in all regions of Brazil, and recruited from public and private schools in their respective regions. Each child was assessed for weight and height. Walk distance was our main outcome. An open-source software environment for statistical computing was used for statistical analysis. We observed a higher average distance walked by boys (531.1 m) than by girls (506.2 m), with a difference of 24.9 m ( P < .001). We established 6MWT reference values for boys with the following equation: Distance = (16.86 × age) + (1.89 × Δ heart rate) - (0.80 × weight) + (336.91 × R1) + (360.91 × R2). For girls the equation is as follows: Distance = (13.54 × age) + (1.62 × Δ heart rate) - (1.28 × weight) + (352.33 × R1) + (394.81 × R2). Reference values were established for the 6MWT in healthy children aged 7-12 y in Brazil. Copyright © 2018 by Daedalus Enterprises.
Compositional analysis of biomass reference materials: Results from an interlaboratory study
Templeton, David W.; Wolfrum, Edward J.; Yen, James H.; ...
2015-10-29
Biomass compositional methods are used to compare different lignocellulosic feedstocks, to measure component balances around unit operations and to determine process yields and therefore the economic viability of biomass-to-biofuel processes. Four biomass reference materials (RMs NIST 8491–8494) were prepared and characterized, via an interlaboratory comparison exercise in the early 1990s to evaluate biomass summative compositional methods, analysts, and laboratories. Having common, uniform, and stable biomass reference materials gives the opportunity to assess compositional data compared to other analysts, to other labs, and to a known compositional value. The expiration date for the original characterization of these RMs was reached andmore » an effort to assess their stability and recharacterize the reference values for the remaining material using more current methods of analysis was initiated. We sent samples of the four biomass RMs to 11 academic, industrial, and government laboratories, familiar with sulfuric acid compositional methods, for recharacterization of the component reference values. In this work, we have used an expanded suite of analytical methods that are more appropriate for herbaceous feedstocks, to recharacterize the RMs’ compositions. We report the median values and the expanded uncertainty values for the four RMs on a dry-mass, whole-biomass basis. The original characterization data has been recalculated using median statistics to facilitate comparisons with this data. We found improved total component closures for three out of the four RMs compared to the original characterization, and the total component closures were near 100 %, which suggests that most components were accurately measured and little double counting occurred. Here, the major components were not statistically different in the recharacterization which suggests that the biomass materials are stable during storage and that additional components, not seen in the original characterization, were quantified here.« less
Freire, Carmen; Koifman, Rosalina Jorge; Fujimoto, Denys; de Oliveira Souza, Vanessa Cristina; Barbosa, Fernando; Koifman, Sergio
2015-06-01
This study aimed to investigate the distribution and factors influencing blood levels of Cadmium (Cd), Arsenic (As), and Manganese (Mn), and to determine their reference values in a sample of blood donors residing in Rio Branco, capital city of Acre State, Brazil. Blood samples were collected from all blood donors attending the Central Hemotherapic Unit in Rio Branco between 2010 and 2011. Among these, 1183 donors (98.9%) answered to a questionnaire on sociodemographic and lifestyle factors. Blood metal concentrations were determined by atomic spectrometry. Association between Cd, As and Mn levels and donors' characteristics was examined by linear regression analysis. Reference values were estimated as the upper limit of the 95% confidence interval of the 95th percentile of metal levels. References values were 0.87 μg L(-1) for Cd, 9.87 μg L(-1) for As, and 29.32 μg L(-1) for Mn. Reference values of Cd and As in smokers were 2.66 and 10.86 μg L(-1), respectively. Factors contributing to increase Cd levels were smoking, ethnicity (non-white), and lower education, whereas drinking tea and non-bottled water were associated with lower Cd. Lower levels of As were associated with higher household income, living near industrial facilities, working in a glass factory, a compost plant or in metal mining activities. Risk factors for Mn exposure were not identified. In general, blood Cd concentrations were in the range of exposure levels reported for other people from the general population, whereas levels of As and Mn were higher than in other non-occupationally exposed populations elsewhere. Copyright © 2015 Elsevier Ltd. All rights reserved.
Development of reference equations for spirometry in Japanese children aged 6-18 years.
Takase, Masato; Sakata, Hiroshi; Shikada, Masahiro; Tatara, Katsuyoshi; Fukushima, Takayoshi; Miyakawa, Tomoo
2013-01-01
Spirometry is the most widely used pulmonary function test and the measured values of spirometric parameters need to be evaluated using reference values predicted for the corresponding race, sex, age, and height. However, none of the existing reference equations for Japanese children covers the entire age range of 6-18 years. The Japanese Society of Pediatric Pulmonology had organized a working group in 2006, in order to develop a new set of national standard reference equations for commonly used spirometric parameters that are applicable through the age range of 6-18 years. Quality assured spirometric data were collected through 2006-2008, from 14 institutions in Japan. We applied multiple regression analysis, using age in years (A), square of age (A(2)), height in meters (H), square of height (H(2)), and the product of age and height (AH) as explanatory variables to predict forced vital capacity (FVC), forced expiratory volume in 1 sec (FEV(1)), peak expiratory flow (PEF), forced expiratory flow between 25% and 75% of the FVC (FEF(25-75%)), instantaneous forced expiratory flow when 50% (FEF(50%)) or 75% (FEF(75%)) of the FVC have been expired. Finally, 1,296 tests (674 boys, 622 girls) formed the reference data set. Distributions of the percent predicted values did not differ by ages, confirming excellent fit of the prediction equations throughout the entire age range from 6 to 18 years. Cut-off values (around 5 percentile points) for the parameters were also determined. We recommend the use of this new set of prediction equations together with suggested cut-off values, for assessment of spirometry in Japanese children and adolescents. Copyright © 2012 Wiley Periodicals, Inc.
1000 Norms Project: protocol of a cross-sectional study cataloging human variation.
McKay, Marnee J; Baldwin, Jennifer N; Ferreira, Paulo; Simic, Milena; Vanicek, Natalie; Hiller, Claire E; Nightingale, Elizabeth J; Moloney, Niamh A; Quinlan, Kate G; Pourkazemi, Fereshteh; Sman, Amy D; Nicholson, Leslie L; Mousavi, Seyed J; Rose, Kristy; Raymond, Jacqueline; Mackey, Martin G; Chard, Angus; Hübscher, Markus; Wegener, Caleb; Fong Yan, Alycia; Refshauge, Kathryn M; Burns, Joshua
2016-03-01
Clinical decision-making regarding diagnosis and management largely depends on comparison with healthy or 'normal' values. Physiotherapists and researchers therefore need access to robust patient-centred outcome measures and appropriate reference values. However there is a lack of high-quality reference data for many clinical measures. The aim of the 1000 Norms Project is to generate a freely accessible database of musculoskeletal and neurological reference values representative of the healthy population across the lifespan. In 2012 the 1000 Norms Project Consortium defined the concept of 'normal', established a sampling strategy and selected measures based on clinical significance, psychometric properties and the need for reference data. Musculoskeletal and neurological items tapping the constructs of dexterity, balance, ambulation, joint range of motion, strength and power, endurance and motor planning will be collected in this cross-sectional study. Standardised questionnaires will evaluate quality of life, physical activity, and musculoskeletal health. Saliva DNA will be analysed for the ACTN3 genotype ('gene for speed'). A volunteer cohort of 1000 participants aged 3 to 100 years will be recruited according to a set of self-reported health criteria. Descriptive statistics will be generated, creating tables of mean values and standard deviations stratified for age and gender. Quantile regression equations will be used to generate age charts and age-specific centile values. This project will be a powerful resource to assist physiotherapists and clinicians across all areas of healthcare to diagnose pathology, track disease progression and evaluate treatment response. This reference dataset will also contribute to the development of robust patient-centred clinical trial outcome measures. Copyright © 2015 Chartered Society of Physiotherapy. Published by Elsevier Ltd. All rights reserved.
Assessment of salivary amylase as a stress biomarker in pregnant patients.
Guglielminotti, J; Dehoux, M; Mentré, F; Bedairia, E; Montravers, P; Desmonts, J-M; Longrois, D
2012-01-01
Chronic stress during pregnancy has been associated with worsened maternal and fetal outcomes. Acute stress immediately before spinal anaesthesia for caesarean section may contribute to hypotension. Therefore objective measures of acute stress may help identify women at risk of adverse outcomes. Salivary alpha-amylase is a stress biomarker that has so far been poorly investigated during pregnancy. The reference change value is the difference between two sequential results that must be exceeded for a change to be considered clinically relevant. Our first aim was to determine if salivary alpha-amylase increased in pregnant patients when subjected to the stress of transfer to the operating room. Our second aim was to determine if changes in salivary alpha-amylase were likely to be clinically significant by measuring reference change value in healthy volunteers. In 15 pregnant patients undergoing planned caesarean section under spinal anaesthesia, salivary alpha-amylase, systolic blood pressure, heart rate, and immediate anxiety were measured on the morning of surgery on the ward and again in the operating room. The reference change value was calculated from 18 healthy volunteers. A median 220% increase in salivary alpha-amylase activity (P=0.0015) and a 17% increase in systolic blood pressure (P=0.0006) were observed between the ward and operating room. No changes of immediate anxiety or heart rate were observed. Reference change value was ±76% in volunteers and 13 of the 15 pregnant patients had a salivary alpha-amylase increase greater than the reference change value. When pregnant women are taken to the operating room, a clinically and statistically significant increase in salivary alpha-amylase was observed. Further studies are required to define its clinical usefulness. Copyright © 2011 Elsevier Ltd. All rights reserved.
Transfer factor, lung volumes, resistance and ventilation distribution in healthy adults.
Verbanck, Sylvia; Van Muylem, Alain; Schuermans, Daniel; Bautmans, Ivan; Thompson, Bruce; Vincken, Walter
2016-01-01
Monitoring of chronic lung disease requires reference values of lung function indices, including putative markers of small airway function, spanning a wide age range.We measured spirometry, transfer factor of the lung for carbon monoxide (TLCO), static lung volume, resistance and ventilation distribution in a healthy population, studying at least 20 subjects per sex and per decade between the ages of 20 and 80 years.With respect to the Global Lung Function Initiative reference data, our subjects had average z-scores for forced expiratory volume in 1 s (FEV1), forced vital capacity (FVC) and FEV1/FVC of -0.12, 0.04 and -0.32, respectively. Reference equations were obtained which could account for a potential dependence of index variability on age and height. This was done for (but not limited to) indices that are pertinent to asthma and chronic obstructive pulmonary disease studies: forced expired volume in 6 s, forced expiratory flow, TLCO, specific airway conductance, residual volume (RV)/total lung capacity (TLC), and ventilation heterogeneity in acinar and conductive lung zones.Deterioration in acinar ventilation heterogeneity and lung clearance index with age were more marked beyond 60 years, and conductive ventilation heterogeneity showed the greatest increase in variability with age. The most clinically relevant deviation from published reference values concerned RV/TLC values, which were considerably smaller than American Thoracic Society/European Respiratory Society-endorsed reference values. Copyright ©ERS 2016.
Professional Values: Key to Professional Development.
ERIC Educational Resources Information Center
Weis, Darlene; Schank, Mary Jane
2002-01-01
Affective domain learning, including values formation, is an important part of humanistic nursing education. The American Nurses Association code of ethics articulates professional values. For full embodiment of these values to occur, educators and the profession must work together. (Contains 30 references.) (SK)
Risk Aversion and the Value of Information.
ERIC Educational Resources Information Center
Eeckhoudt, Louis; Godfroid, Phillippe
2000-01-01
Explains why risk aversion does not always induce a greater information value, but instead may induce a lower information value when increased. Presents a basic model defining the concept of perfect information value and providing a numerical illustration. Includes references. (CMK)
Approximate circuits for increased reliability
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hamlet, Jason R.; Mayo, Jackson R.
2015-08-18
Embodiments of the invention describe a Boolean circuit having a voter circuit and a plurality of approximate circuits each based, at least in part, on a reference circuit. The approximate circuits are each to generate one or more output signals based on values of received input signals. The voter circuit is to receive the one or more output signals generated by each of the approximate circuits, and is to output one or more signals corresponding to a majority value of the received signals. At least some of the approximate circuits are to generate an output value different than the referencemore » circuit for one or more input signal values; however, for each possible input signal value, the majority values of the one or more output signals generated by the approximate circuits and received by the voter circuit correspond to output signal result values of the reference circuit.« less
Reference values of bone stiffness index and C-terminal telopeptide in healthy European children.
Herrmann, D; Intemann, T; Lauria, F; Mårild, S; Molnár, D; Moreno, L A; Sioen, I; Tornaritis, M; Veidebaum, T; Pigeot, I; Ahrens, W
2014-09-01
Quantitative ultrasound measurements and bone metabolic markers can help to monitor bone health and to detect impaired skeletal development. Population-based reference values for children may serve as a basis for preventive measures to reduce the risk of osteoporosis and osteoporotic fractures in later life. This is the first paper providing age-, sex- and height-specific reference values for bone stiffness index (SI) and serum carboxy-terminal cross-linking telopeptide of type I collagen (CTX) in healthy, apparently prepubertal children. In the population-based IDEFICS baseline survey (2007-2008) and follow-up (2009-2010), 18,745 children from eight European countries were newly recruited. A total of 10,791 2-10.9-year-old and 1646 3-8.9-year-old healthy children provided data on SI of the right and left calcaneus and serum CTX, respectively. Furthermore, height and weight were measured. Percentile curves were calculated using the General Additive Model for Location Scale and Shape (GAMLSS) to model the distribution of SI and CTX depending on multiple covariates while accounting for dispersion, skewness, and the kurtosis of this distribution. SI was negatively associated with age and height in children aged 2-5 years, whereas a positive association was observed in children aged 6-10 years. The dip in SI occurred at older age for higher SI percentiles and was observed earlier in taller children than in smaller children. The CTX reference curves showed a linear-positive association with age and height. No major sex differences were observed for the SI and CTX reference values. These reference data lay the ground to evaluate bone growth and metabolism in prepubertal children in epidemiological and clinical settings. They may also inform clinical practice to monitor skeletal development and to assess adverse drug reactions during medical treatments.
Ichihara, Kiyoshi; Ozarda, Yesim; Barth, Julian H; Klee, George; Qiu, Ling; Erasmus, Rajiv; Borai, Anwar; Evgina, Svetlana; Ashavaid, Tester; Khan, Dilshad; Schreier, Laura; Rolle, Reynan; Shimizu, Yoshihisa; Kimura, Shogo; Kawano, Reo; Armbruster, David; Mori, Kazuo; Yadav, Binod K
2017-04-01
The IFCC Committee on Reference Intervals and Decision Limits coordinated a global multicenter study on reference values (RVs) to explore rational and harmonizable procedures for derivation of reference intervals (RIs) and investigate the feasibility of sharing RIs through evaluation of sources of variation of RVs on a global scale. For the common protocol, rather lenient criteria for reference individuals were adopted to facilitate harmonized recruitment with planned use of the latent abnormal values exclusion (LAVE) method. As of July 2015, 12 countries had completed their study with total recruitment of 13,386 healthy adults. 25 analytes were measured chemically and 25 immunologically. A serum panel with assigned values was measured by all laboratories. RIs were derived by parametric and nonparametric methods. The effect of LAVE methods is prominent in analytes which reflect nutritional status, inflammation and muscular exertion, indicating that inappropriate results are frequent in any country. The validity of the parametric method was confirmed by the presence of analyte-specific distribution patterns and successful Gaussian transformation using the modified Box-Cox formula in all countries. After successful alignment of RVs based on the panel test results, nearly half the analytes showed variable degrees of between-country differences. This finding, however, requires confirmation after adjusting for BMI and other sources of variation. The results are reported in the second part of this paper. The collaborative study enabled us to evaluate rational methods for deriving RIs and comparing the RVs based on real-world datasets obtained in a harmonized manner. Copyright © 2016 The Authors. Published by Elsevier B.V. All rights reserved.
Shokouhi, Sepideh; Mckay, John W; Baker, Suzanne L; Kang, Hakmook; Brill, Aaron B; Gwirtsman, Harry E; Riddle, William R; Claassen, Daniel O; Rogers, Baxter P
2016-01-15
Semiquantitative methods such as the standardized uptake value ratio (SUVR) require normalization of the radiotracer activity to a reference tissue to monitor changes in the accumulation of amyloid-β (Aβ) plaques measured with positron emission tomography (PET). The objective of this study was to evaluate the effect of reference tissue normalization in a test-retest (18)F-florbetapir SUVR study using cerebellar gray matter, white matter (two different segmentation masks), brainstem, and corpus callosum as reference regions. We calculated the correlation between (18)F-florbetapir PET and concurrent cerebrospinal fluid (CSF) Aβ1-42 levels in a late mild cognitive impairment cohort with longitudinal PET and CSF data over the course of 2 years. In addition to conventional SUVR analysis using mean and median values of normalized brain radiotracer activity, we investigated a new image analysis technique-the weighted two-point correlation function (wS2)-to capture potentially more subtle changes in Aβ-PET data. Compared with the SUVRs normalized to cerebellar gray matter, all cerebral-to-white matter normalization schemes resulted in a higher inverse correlation between PET and CSF Aβ1-42, while the brainstem normalization gave the best results (high and most stable correlation). Compared with the SUVR mean and median values, the wS2 values were associated with the lowest coefficient of variation and highest inverse correlation to CSF Aβ1-42 levels across all time points and reference regions, including the cerebellar gray matter. The selection of reference tissue for normalization and the choice of image analysis method can affect changes in cortical (18)F-florbetapir uptake in longitudinal studies.
The environmental zero-point problem in evolutionary reaction norm modeling.
Ergon, Rolf
2018-04-01
There is a potential problem in present quantitative genetics evolutionary modeling based on reaction norms. Such models are state-space models, where the multivariate breeder's equation in some form is used as the state equation that propagates the population state forward in time. These models use the implicit assumption of a constant reference environment, in many cases set to zero. This zero-point is often the environment a population is adapted to, that is, where the expected geometric mean fitness is maximized. Such environmental reference values follow from the state of the population system, and they are thus population properties. The environment the population is adapted to, is, in other words, an internal population property, independent of the external environment. It is only when the external environment coincides with the internal reference environment, or vice versa, that the population is adapted to the current environment. This is formally a result of state-space modeling theory, which is an important theoretical basis for evolutionary modeling. The potential zero-point problem is present in all types of reaction norm models, parametrized as well as function-valued, and the problem does not disappear when the reference environment is set to zero. As the environmental reference values are population characteristics, they ought to be modeled as such. Whether such characteristics are evolvable is an open question, but considering the complexity of evolutionary processes, such evolvability cannot be excluded without good arguments. As a straightforward solution, I propose to model the reference values as evolvable mean traits in their own right, in addition to other reaction norm traits. However, solutions based on an evolvable G matrix are also possible.
Optimized angiotensin-converting enzyme activity assay for the accurate diagnosis of sarcoidosis.
Csongrádi, Alexandra; Enyedi, Attila; Takács, István; Végh, Tamás; Mányiné, Ivetta S; Pólik, Zsófia; Altorjay, István Tibor; Balla, József; Balla, György; Édes, István; Kappelmayer, János; Tóth, Attila; Papp, Zoltán; Fagyas, Miklós
2018-06-27
Serum angiotensin-converting enzyme (ACE) activity determination can aid the early diagnosis of sarcoidosis. We aimed to optimize a fluorescent kinetic assay for ACE activity by screening the confounding effects of endogenous ACE inhibitors and interfering factors. Genotype-dependent and genotype-independent reference values of ACE activity were established, and their diagnostic accuracies were validated in a clinical study. Internally quenched fluorescent substrate, Abz-FRK(Dnp)P-OH was used for ACE-activity measurements. A total of 201 healthy individuals and 59 presumably sarcoidotic patients were enrolled into this study. ACE activity and insertion/deletion (I/D) genotype of the ACE gene were determined. Here we report that serum samples should be diluted at least 35-fold to eliminate the endogenous inhibitor effect of albumin. No significant interferences were detected: up to a triglyceride concentration of 16 mM, a hemoglobin concentration of 0.71 g/L and a bilirubin concentration of 150 μM. Genotype-dependent reference intervals were considered as 3.76-11.25 U/L, 5.22-11.59 U/L, 7.19-14.84 U/L for II, ID and DD genotypes, respectively. I/D genotype-independent reference interval was established as 4.85-13.79 U/L. An ACE activity value was considered positive for sarcoidosis when it exceeded the upper limit of the reference interval. The optimized assay with genotype-dependent reference ranges resulted in 42.5% sensitivity, 100% specificity, 100% positive predictive value and 32.4% negative predictive value in the clinical study, whereas the genotype-independent reference range proved to have inferior diagnostic efficiency. An optimized fluorescent kinetic assay of serum ACE activity combined with ACE I/D genotype determination is an alternative to invasive biopsy for confirming the diagnosis of sarcoidosis in a significant percentage of patients.
Simulation studies of the fidelity of biomolecular structure ensemble recreation
NASA Astrophysics Data System (ADS)
Lätzer, Joachim; Eastwood, Michael P.; Wolynes, Peter G.
2006-12-01
We examine the ability of Bayesian methods to recreate structural ensembles for partially folded molecules from averaged data. Specifically we test the ability of various algorithms to recreate different transition state ensembles for folding proteins using a multiple replica simulation algorithm using input from "gold standard" reference ensembles that were first generated with a Gō-like Hamiltonian having nonpairwise additive terms. A set of low resolution data, which function as the "experimental" ϕ values, were first constructed from this reference ensemble. The resulting ϕ values were then treated as one would treat laboratory experimental data and were used as input in the replica reconstruction algorithm. The resulting ensembles of structures obtained by the replica algorithm were compared to the gold standard reference ensemble, from which those "data" were, in fact, obtained. It is found that for a unimodal transition state ensemble with a low barrier, the multiple replica algorithm does recreate the reference ensemble fairly successfully when no experimental error is assumed. The Kolmogorov-Smirnov test as well as principal component analysis show that the overlap of the recovered and reference ensembles is significantly enhanced when multiple replicas are used. Reduction of the multiple replica ensembles by clustering successfully yields subensembles with close similarity to the reference ensembles. On the other hand, for a high barrier transition state with two distinct transition state ensembles, the single replica algorithm only samples a few structures of one of the reference ensemble basins. This is due to the fact that the ϕ values are intrinsically ensemble averaged quantities. The replica algorithm with multiple copies does sample both reference ensemble basins. In contrast to the single replica case, the multiple replicas are constrained to reproduce the average ϕ values, but allow fluctuations in ϕ for each individual copy. These fluctuations facilitate a more faithful sampling of the reference ensemble basins. Finally, we test how robustly the reconstruction algorithm can function by introducing errors in ϕ comparable in magnitude to those suggested by some authors. In this circumstance we observe that the chances of ensemble recovery with the replica algorithm are poor using a single replica, but are improved when multiple copies are used. A multimodal transition state ensemble, however, turns out to be more sensitive to large errors in ϕ (if appropriately gauged) and attempts at successful recreation of the reference ensemble with simple replica algorithms can fall short.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Simbeck, D.J.
1997-06-01
Reference toxicant testing using juvenile freshwater mussels was conducted as part of the CR-ERP biomonitoring study of Clinch River sediments to assess the sensitivity of test organisms and the overall performance of the test. Tests were conducted using moderately hard synthetic water spiked with known concentrations of copper as copper sulfate. Toxicity testing of copper sulfate reference toxicant was conducted from May 12-21, 1993. The organisms used for testing were juvenile fresh-water mussels (Anodonta imbecillis). Results from this test showed an LC{sub 50} value of 1.12 mg Cu/L which is lower than the value of 2.02 mg Cu/L obtained inmore » a previous test. Too few tests have been conducted with copper as the toxicant to determine a normal range of values.« less
The effect of geographical indices on left ventricular structure in healthy Han Chinese population
NASA Astrophysics Data System (ADS)
Cen, Minyi; Ge, Miao; Liu, Yonglin; Wang, Congxia; Yang, Shaofang
2017-02-01
The left ventricular posterior wall thickness (LVPWT) and interventricular septum thickness (IVST) are generally regarded as the functional parts of the left ventricular (LV) structure. This paper aims to examine the effects of geographical indices on healthy Han adults' LV structural indices and to offer a scientific basis for developing a unified standard for the reference values of adults' LV structural indices in China. Fifteen terrain, climate, and soil indices were examined as geographical explanatory variables. Statistical analysis was performed using correlation analysis. Moreover, a back propagation neural network (BPNN) and a support vector regression (SVR) were applied to developing models to predict the values of two indices. After the prediction models were built, distribution maps were produced. The results show that LV structural indices are characteristically associated with latitude, longitude, altitude, average temperature, average wind velocity, topsoil sand fraction, topsoil silt fraction, topsoil organic carbon, and topsoil sodicity. The model test analyses show the BPNN model possesses better simulative and predictive ability in comparison with the SVR model. The distribution maps of the LV structural indices show that, in China, the values are higher in the west and lower in the east. These results demonstrate that the reference values of the adults' LV structural indices will be different affected by different geographical environment. The reference values of LV structural indices in one region can be calculated by setting up a BPNN, which showed better applicability in this study. The distribution of the reference values of the LV structural indices can be seen clearly on the geographical distribution map.
The effect of geographical indices on left ventricular structure in healthy Han Chinese population.
Cen, Minyi; Ge, Miao; Liu, Yonglin; Wang, Congxia; Yang, Shaofang
2017-02-01
The left ventricular posterior wall thickness (LVPWT) and interventricular septum thickness (IVST) are generally regarded as the functional parts of the left ventricular (LV) structure. This paper aims to examine the effects of geographical indices on healthy Han adults' LV structural indices and to offer a scientific basis for developing a unified standard for the reference values of adults' LV structural indices in China. Fifteen terrain, climate, and soil indices were examined as geographical explanatory variables. Statistical analysis was performed using correlation analysis. Moreover, a back propagation neural network (BPNN) and a support vector regression (SVR) were applied to developing models to predict the values of two indices. After the prediction models were built, distribution maps were produced. The results show that LV structural indices are characteristically associated with latitude, longitude, altitude, average temperature, average wind velocity, topsoil sand fraction, topsoil silt fraction, topsoil organic carbon, and topsoil sodicity. The model test analyses show the BPNN model possesses better simulative and predictive ability in comparison with the SVR model. The distribution maps of the LV structural indices show that, in China, the values are higher in the west and lower in the east. These results demonstrate that the reference values of the adults' LV structural indices will be different affected by different geographical environment. The reference values of LV structural indices in one region can be calculated by setting up a BPNN, which showed better applicability in this study. The distribution of the reference values of the LV structural indices can be seen clearly on the geographical distribution map.
Odhiambo, Collins; Oyaro, Boaz; Odipo, Richard; Otieno, Fredrick; Alemnji, George; Williamson, John; Zeh, Clement
2015-01-01
Important differences have been demonstrated in laboratory parameters from healthy persons in different geographical regions and populations, mostly driven by a combination of genetic, demographic, nutritional, and environmental factors. Despite this, European and North American derived laboratory reference intervals are used in African countries for patient management, clinical trial eligibility, and toxicity determination; which can result in misclassification of healthy persons as having laboratory abnormalities. An observational prospective cohort study known as the Kisumu Incidence Cohort Study (KICoS) was conducted to estimate the incidence of HIV seroconversion and identify determinants of successful recruitment and retention in preparation for an HIV vaccine/prevention trial among young adults and adolescents in western Kenya. Laboratory values generated from the KICoS were compared to published region-specific reference intervals and the 2004 NIH DAIDS toxicity tables used for the trial. About 1106 participants were screened for the KICoS between January 2007 and June 2010. Nine hundred and fifty-three participants aged 16 to 34 years, HIV-seronegative, clinically healthy, and non-pregnant were selected for this analysis. Median and 95% reference intervals were calculated for hematological and biochemistry parameters. When compared with both published region-specific reference values and the 2004 NIH DAIDS toxicity table, it was shown that the use of locally established reference intervals would have resulted in fewer participants classified as having abnormal hematological or biochemistry values compared to US derived reference intervals from DAIDS (10% classified as abnormal by local parameters vs. >40% by US DAIDS). Blood urea nitrogen was most often out of range if US based intervals were used: <10% abnormal by local intervals compared to >83% by US based reference intervals. Differences in reference intervals for hematological and biochemical parameters between western and African populations highlight importance of developing local reference intervals for clinical care and trials in Africa.
USDA-ARS?s Scientific Manuscript database
Standard Reference Material (SRM) 3280 Multivitamin/Multielement Tablets was issued by the National Institute of Standards and Technology (NIST) in 2009 and has certified and reference mass fraction values for 13 vitamins, 26 elements, and 2 carotenoids. Elements were measured using two or more ana...
21 CFR 660.22 - Potency requirements with reference preparations.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 7 2011-04-01 2010-04-01 true Potency requirements with reference preparations. 660.22 Section 660.22 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN.... Products for which reference Blood Grouping Reagents are available shall have a potency titer value at...
21 CFR 660.22 - Potency requirements with reference preparations.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 7 2010-04-01 2010-04-01 false Potency requirements with reference preparations. 660.22 Section 660.22 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN.... Products for which reference Blood Grouping Reagents are available shall have a potency titer value at...
Aylward, Lesa L; Kirman, Chris R; Blount, Ben C; Hays, Sean M
2010-10-01
The National Health and Nutrition Examination Survey (NHANES) generates population-representative biomonitoring data for many chemicals including volatile organic compounds (VOCs) in blood. However, no health or risk-based screening values are available to evaluate these data from a health safety perspective or to use in prioritizing among chemicals for possible risk management actions. We gathered existing risk assessment-based chronic exposure reference values such as reference doses (RfDs), reference concentrations (RfCs), tolerable daily intakes (TDIs), cancer slope factors, etc. and key pharmacokinetic model parameters for 47 VOCs. Using steady-state solutions to a generic physiologically-based pharmacokinetic (PBPK) model structure, we estimated chemical-specific steady-state venous blood concentrations across chemicals associated with unit oral and inhalation exposure rates and with chronic exposure at the identified exposure reference values. The geometric means of the slopes relating modeled steady-state blood concentrations to steady-state exposure to a unit oral dose or unit inhalation concentration among 38 compounds with available pharmacokinetic parameters were 12.0 microg/L per mg/kg-d (geometric standard deviation [GSD] of 3.2) and 3.2 microg/L per mg/m(3) (GSD=1.7), respectively. Chemical-specific blood concentration screening values based on non-cancer reference values for both oral and inhalation exposure range from 0.0005 to 100 microg/L; blood concentrations associated with cancer risk-specific doses at the 1E-05 risk level ranged from 5E-06 to 6E-02 microg/L. The distribution of modeled steady-state blood concentrations associated with unit exposure levels across VOCs may provide a basis for estimating blood concentration screening values for VOCs that lack chemical-specific pharmacokinetic data. The screening blood concentrations presented here provide a tool for risk assessment-based evaluation of population biomonitoring data for VOCs and are most appropriately applied to central tendency estimates for such datasets. Copyright (c) 2010 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Condon, D.; Noble, S.; McLean, N.; Bowring, S. A.
2009-12-01
We have determined 238U/235U ratios for a suite of commonly used natural (CRM 112a, SRM 950a, HU-1) and synthetic (IRMM 184 and CRM U500) uranium reference materials in addition to several U-bearing accessory phases (zircon and monazite) by thermal ionisation mass-spectrometry (TIMS) using the IRMM 3636 233U-236U double spike to accurately correct for mass fractionation. The 238U/235U values for the natural uranium reference materials differ, by up to 0.1%, from the widely used ‘consensus’ value (137.88) with all having 238U/235U values less than 137.88. Similarly, initial 238U/235U data from zircon and monazite yield 238U/235U values that are lower than the ‘consensus’ value. The data obtained from U-bearing minerals is used to assess how the uncertainty in the 238U/235U ratio contributes to the systematic discordance observed in 238U/206Pb and 235U/207Pb dates (Mattinson, 2000; Schoene et al., 2006) which has traditionally been wholly attributed to error in the U decay constants. The 238U/235U determinations made on the synthetic reference materials yield results that are considerably more precise and accurate than the certified values (0.02% vs. 0.1% for CRM U500). The calibration of isotopic tracers used for U-daughter geochronology that are partially based upon these reference materials, and the resultant age determinations, will benefit from increased accuracy and precision. Mattinson, J.M., 2000. Revising the “gold standard”—the uranium decay constants of Jaffey et al., 1971. Eos Trans. AGU, Spring Meet. Suppl., Abstract V61A-02. Schoene B., Crowley J.L., Condon D.C., Schmitz M.D., Bowring S.A., 2006, Reassessing the uranium decay constants for geochronology using ID-TIMS U-Pb data. Geochimica et Cosmochimica Acta 70: 426-445
[The reference of normal values of the sacroiliac joint index in bone scintigraphy].
Sebastjanowicz, Przemysław; Iwanowski, Jacek; Piwowarska-Bilska, Hanna; Elbl, Bogumiła; Birkenfeld, Bożena
Scintigraphy of sacroiliac joints as functional imaging provides unique information on the existing disease process. By using radiopharmaceuticals that allow imaging of the metabolic activity within the joint, it is possible to assess the stage of the disease, even when there are no lesions in radiological images. Quantitative analysis of scintigrams of sacroiliac joints is performed by comparing the uptake in both of them in relation to the uptake in the sacral bone area. The values of sacroiliac (SI/S) indices are influenced by the age of the patient, sex, state of health, and a range of individual biological features. Therefore, reference values of SI/S ratios are very important for medical specialists who describe and diagnose locomotor system diseases. The aim of this paper is to develop a reference range of sacroiliac ratios. The innovativeness of this paper involves examining sacroiliac ratios for various age groups, in children and adult patients, taking their sex into consideration. The study comprised a group of 335 people with proper bone scintigraphy. These people were divided into children and patients aged ≥21. Children were divided into 4 age groups (1–5; 6–10; 11–15; 16–20) and adults into 6 age groups (21–30; 31–40; 41–50; 51–60; 61–70; ≥71). Sacroiliac ratios were calculated using the method of three rectangular region of interests located on the left and right sacroiliac joint and on the sacral bone. The sacroiliac ratio was calculated for both joints by dividing the average number of counts within a selected sacroiliac joint by the average number of counts within the sacral bone. SI/S borderline reference values covered the range of 1.18÷2.28 that was obtained for children aged ≤5 and for the group of 11–15-year-olds. Considerable discrepancies in the values of the coefficient for women and men were seen among 31–50-year-olds. Borderline reference results for the entire control group cover the range of 1.18 ±2.28. The lower reference value applies to ≤5-year-olds, whereas the higher value applies to the group of 11–15-year-olds. The standard deviation value obtained was highest in paediatric patients. The results indicate the occurrence of significant individual differences between patients in this age group.
Implications of false positive serology of Toxoplasma gondii in a pre-transplant patient.
Beal, Stacy; Racsa, Lori; Alatoom, Adnan
2014-01-01
A 21-year-old white male with cystic fibrosis. Pre-transplant workup in preparation for bilateral lung transplant. Cystic fibrosis diagnosed at age 3, onset of insulin-dependent diabetes around age 20, and multiple hospitalizations for pulmonary and gastrointestinal complications. FAMILY AND SOCIAL HISTORY: The patient lives with his father and stepmother, has a pet bearded dragon, and has multiple tattoos and piercings. His stepmother has a cat, but he does not clean the litter box. The pre-transplant workup included several tests for infectious diseases, tests of organ function, radiology studies, and markers of malignancy. The only significant finding was a positive Toxoplasma gondii (T. gondii) IgM titer (> or = 1:40) (reference values for IgM: negative; < 1:40, positive; > or = 1:40) and IgG (1:2048) (reference values for IgG: negative; < 1:16, equivocal; > or = 1:16 - < 1:256, positive; > or = 1:256). Testing was done by indirect immunofluorescence assay (IFA) in April 2012 in our hospital laboratory. The patient was treated with sulfadiazine, leucovorin, and pyrimethamine. Three months later (July), he returned for follow-up testing. Real-time polymerase chain reaction (PCR) for T. gondii DNA performed by a reference laboratory was negative. One month later (August), Toxoplasma serology was performed by enzyme-linked immunosorbent assay (ELISA) by a different reference laboratory and showed an elevated IgM of 0.95 IU/mL (reference values: negative; < 0.55 IU/mL, equivocal; > or = 0.55- < 0.65 IU/mL, positive; > or = 0.65 IU/mL) and a normal level of IgG (< 4 IU/mL). At this time, PCR was repeated and was negative. An additional month later (September), the patient's serology studies were performed at a third reference laboratory and showed an elevated IgM of 1.32 IU/mL (reference values: negative; 0.89, equivocal; 0.90 - 1.09, positive; > 1.10) and a normal IgG.
New reference values for the Alberta Infant Motor Scale need to be established.
Fleuren, K M W; Smit, L S; Stijnen, Th; Hartman, A
2007-03-01
The Alberta Infant Motor Scale (AIMS) is an infant developmental test, which can be used to evaluate motor performance from birth to independent walking. Between 1990 and 1992 Piper and Darrah determined reference values in a cohort in Canada. To our knowledge no study has been carried out to determine whether the Canadian data are representative for other countries. In the present study we aimed to establish whether the AIMS test needs new reference values for Dutch children. Motor performance of 100 Dutch children, aged 0-12 months, was measured using the AIMS test. The mean percentile score of the Dutch children was 28.8 (+/-22.9, range 1-85). The percentile scores of the group were significantly lower than scores of the Canadian norm population (p < 0.001), whereby 75% of the Dutch children scored below the 50th percentile. These lower scores were not be explained by sex, racial differences or congenital disorders and were seen in all age groups. We conclude that new reference values on the AIMS test for the age group of 0-12 months need to be established for Dutch children. It is recommended that the need for new normative data is also determined in all other European countries.
The dimensional salience solution to the expectancy-value muddle: an extension.
Newton, Joshua D; Newton, Fiona J; Ewing, Michael T
2014-01-01
The theory of reasoned action (TRA) specifies a set of expectancy-value, belief-based frameworks that underpin attitude (behavioural beliefs × outcome evaluations) and subjective norm (normative beliefs × motivation to comply). Unfortunately, the most common method for analysing these frameworks generates statistically uninterpretable findings, resulting in what has been termed the 'expectancy-value muddle'. Recently, however, a dimensional salience approach was found to resolve this muddle for the belief-based framework underpinning attitude. An online survey of 262 participants was therefore conducted to determine whether the dimensional salience approach could also be applied to the belief-based framework underpinning subjective norm. Results revealed that motivations to comply were greater for salient, as opposed to non-salient, social referents. The belief-based framework underpinning subjective norm was therefore represented by evaluating normative belief ratings for salient social referents. This modified framework was found to predict subjective norm, although predictions were greater when participants were forced to select five salient social referents rather than being free to select any number of social referents. These findings validate the use of the dimensional salience approach for examining the belief-based frameworks underpinning subjective norm. As such, this approach provides a complete solution to addressing the expectancy-value muddle in the TRA.
Lu, Xianbo; Chen, Jiping; Wang, Shuqiu; Zou, Lili; Tian, Yuzeng; Ni, Yuwen; Su, Fan
2012-09-01
A method for the preparation and certification of the reference material of organochlorine pesticides (OCPs) and polychlorinated biphenyls (PCBs) in mussel tissue is described. The mussel tissue from Dalian Bay was frozen-dried, comminuted, sieved, homogenized, packaged, and sterilized by 60Co radiation sterilization in turn. The certified values for 18 OCPs and 16 PCBs were determined by high resolution gas chromatography/high resolution mass spectrometry (HRGC/HRMS) using isotope dilution and internal standard quantitation techniques. The certified values were validated and given based on seven accredited laboratories, and these values are traceable to the SI (international system of units) through gravimetrically prepared standards of established purity and measurement intercomparisons. The certified values of PCBs and OCPs in mussel span 4 orders of magnitude with a relative uncertainty of about 10%. This material is a natural biological material with confirmed good homogeneity and stability, and it was approved as the grade "primary reference material" (GBW10069) in June 2012 in China. This reference material provided necessary quality control products for our country to implement the Stockholm Treaty on the monitoring of persistent organic pollutants (POPs). The material is intended to be used for the method validation and quality control in the determination of OCPs and PCBs in biota samples.
Travison, Thomas G.; Vesper, Hubert W.; Orwoll, Eric; Wu, Frederick; Kaufman, Jean Marc; Wang, Ying; Lapauw, Bruno; Fiers, Tom; Matsumoto, Alvin M.
2017-01-01
Background: Reference ranges for testosterone are essential for making a diagnosis of hypogonadism in men. Objective: To establish harmonized reference ranges for total testosterone in men that can be applied across laboratories by cross-calibrating assays to a reference method and standard. Population: The 9054 community-dwelling men in cohort studies in the United States and Europe: Framingham Heart Study; European Male Aging Study; Osteoporotic Fractures in Men Study; and Male Sibling Study of Osteoporosis. Methods: Testosterone concentrations in 100 participants in each of the four cohorts were measured using a reference method at Centers for Disease Control and Prevention (CDC). Generalized additive models and Bland-Altman analyses supported the use of normalizing equations for transformation between cohort-specific and CDC values. Normalizing equations, generated using Passing-Bablok regression, were used to generate harmonized values, which were used to derive standardized, age-specific reference ranges. Results: Harmonization procedure reduced intercohort variation between testosterone measurements in men of similar ages. In healthy nonobese men, 19 to 39 years, harmonized 2.5th, 5th, 50th, 95th, and 97.5th percentile values were 264, 303, 531, 852, and 916 ng/dL, respectively. Age-specific harmonized testosterone concentrations in nonobese men were similar across cohorts and greater than in all men. Conclusion: Harmonized normal range in a healthy nonobese population of European and American men, 19 to 39 years, is 264 to 916 ng/dL. A substantial proportion of intercohort variation in testosterone levels is due to assay differences. These data demonstrate the feasibility of generating harmonized reference ranges for testosterone that can be applied to assays, which have been calibrated to a reference method and calibrator. PMID:28324103
Fernández-Cidón, Bárbara; Padró-Miquel, Ariadna; Alía-Ramos, Pedro; Castro-Castro, María José; Fanlo-Maresma, Marta; Dot-Bach, Dolors; Valero-Politi, José; Pintó-Sala, Xavier; Candás-Estébanez, Beatriz
2017-01-01
High serum concentrations of small dense low-density lipoprotein cholesterol (sd-LDL-c) particles are associated with risk of cardiovascular disease (CVD). Their clinical application has been hindered as a consequence of the laborious current method used for their quantification. Optimize a simple and fast precipitation method to isolate sd-LDL particles and establish a reference interval in a Mediterranean population. Forty-five serum samples were collected, and sd-LDL particles were isolated using a modified heparin-Mg 2+ precipitation method. sd-LDL-c concentration was calculated by subtracting high-density lipoprotein cholesterol (HDL-c) from the total cholesterol measured in the supernatant. This method was compared with the reference method (ultracentrifugation). Reference values were estimated according to the Clinical and Laboratory Standards Institute and The International Federation of Clinical Chemistry and Laboratory Medicine recommendations. sd-LDL-c concentration was measured in serums from 79 subjects with no lipid metabolism abnormalities. The Passing-Bablok regression equation is y = 1.52 (0.72 to 1.73) + 0.07 x (-0.1 to 0.13), demonstrating no significant statistical differences between the modified precipitation method and the ultracentrifugation reference method. Similarly, no differences were detected when considering only sd-LDL-c from dyslipidemic patients, since the modifications added to the precipitation method facilitated the proper sedimentation of triglycerides and other lipoproteins. The reference interval for sd-LDL-c concentration estimated in a Mediterranean population was 0.04-0.47 mmol/L. An optimization of the heparin-Mg 2+ precipitation method for sd-LDL particle isolation was performed, and reference intervals were established in a Spanish Mediterranean population. Measured values were equivalent to those obtained with the reference method, assuring its clinical application when tested in both normolipidemic and dyslipidemic subjects.
Adeli, Khosrow; Higgins, Victoria; Nieuwesteeg, Michelle; Raizman, Joshua E; Chen, Yunqi; Wong, Suzy L; Blais, David
2015-08-01
Biological covariates such as age and sex can markedly influence biochemical marker reference values, but no comprehensive study has examined such changes across pediatric, adult, and geriatric ages. The Canadian Health Measures Survey (CHMS) collected comprehensive nationwide health information and blood samples from children and adults in the household population and, in collaboration with the Canadian Laboratory Initiative on Pediatric Reference Intervals (CALIPER), examined biological changes in biochemical markers from pediatric to geriatric age, establishing a comprehensive reference interval database for routine disease biomarkers. The CHMS collected health information, physical measurements, and biosamples (blood and urine) from approximately 12 000 Canadians aged 3-79 years and measured 24 biochemical markers with the Ortho Vitros 5600 FS analyzer or a manual microplate. By use of CLSI C28-A3 guidelines, we determined age- and sex-specific reference intervals, including corresponding 90% CIs, on the basis of specific exclusion criteria. Biochemical marker reference values exhibited dynamic changes from pediatric to geriatric age. Most biochemical markers required some combination of age and/or sex partitioning. Two or more age partitions were required for all analytes except bicarbonate, which remained constant throughout life. Additional sex partitioning was required for most biomarkers, except bicarbonate, total cholesterol, total protein, urine iodine, and potassium. Understanding the fluctuations in biochemical markers over a wide age range provides important insight into biological processes and facilitates clinical application of biochemical markers to monitor manifestation of various disease states. The CHMS-CALIPER collaboration addresses this important evidence gap and allows the establishment of robust pediatric and adult reference intervals. © 2015 American Association for Clinical Chemistry.
Choice of Reference Serum Creatinine in Defining AKI
Siew, Edward D.; Matheny, Michael E.
2015-01-01
Background/Aims The study of acute kidney injury (AKI) has expanded with the increasing availability of electronic health records and the use of standardized definitions. Understanding the impact of AKI between settings is limited by heterogeneity in the selection of reference creatinine to anchor the definition of AKI. In this mini-review, we discuss different approaches used to select reference creatinine and their relative merits and limitations. Methods We reviewed the literature to obtain representative examples of published baseline creatinine definitions when pre-hospital data were not available, as well as literature evaluating estimation of baseline renal function, using Pubmed and reference back-tracing within known works. Results 1) Prehospital creatinine values are useful in determining reference creatinine, and in high-risk populations, the mean outpatient serum creatinine value 7-365 days before hospitalization closely approximates nephrology adjudication, 2) in patients without pre-hospital data, the eGFR 75 approach does not reliably estimate true AKI incidence in most at-risk populations 3) using the lowest inpatient serum creatinine may be reasonable, especially in those with preserved kidney function, but may generously estimate AKI incidence and severity and miss community-acquired AKI that does not fully resolve, 4) using more specific definitions of AKI (e.g. KIDGO Stage 2 and 3) may help to reduce the effects of misclassification when using surrogate values, and 5) leveraging available clinical data may help refine the estimate of reference creatinine. Conclusions Choosing reference creatinine for AKI calculation is important for AKI classification and study interpretation. We recommend obtaining data on pre-hospital kidney function, wherever possible. In studies where surrogate estimates are used, transparency in how they are applied and discussion that informs the reader of potential biases should be provided. Further work to refine the estimation of reference creatinine is needed. PMID:26332325
Reference Values for Body Composition and Anthropometric Measurements in Athletes
Santos, Diana A.; Dawson, John A.; Matias, Catarina N.; Rocha, Paulo M.; Minderico, Cláudia S.; Allison, David B.; Sardinha, Luís B.; Silva, Analiza M.
2014-01-01
Background Despite the importance of body composition in athletes, reference sex- and sport-specific body composition data are lacking. We aim to develop reference values for body composition and anthropometric measurements in athletes. Methods Body weight and height were measured in 898 athletes (264 female, 634 male), anthropometric variables were assessed in 798 athletes (240 female and 558 male), and in 481 athletes (142 female and 339 male) with dual-energy X-ray absorptiometry (DXA). A total of 21 different sports were represented. Reference percentiles (5th, 25th, 50th, 75th, and 95th) were calculated for each measured value, stratified by sex and sport. Because sample sizes within a sport were often very low for some outcomes, the percentiles were estimated using a parametric, empirical Bayesian framework that allowed sharing information across sports. Results We derived sex- and sport-specific reference percentiles for the following DXA outcomes: total (whole body scan) and regional (subtotal, trunk, and appendicular) bone mineral content, bone mineral density, absolute and percentage fat mass, fat-free mass, and lean soft tissue. Additionally, we derived reference percentiles for height-normalized indexes by dividing fat mass, fat-free mass, and appendicular lean soft tissue by height squared. We also derived sex- and sport-specific reference percentiles for the following anthropometry outcomes: weight, height, body mass index, sum of skinfold thicknesses (7 skinfolds, appendicular skinfolds, trunk skinfolds, arm skinfolds, and leg skinfolds), circumferences (hip, arm, midthigh, calf, and abdominal circumferences), and muscle circumferences (arm, thigh, and calf muscle circumferences). Conclusions These reference percentiles will be a helpful tool for sports professionals, in both clinical and field settings, for body composition assessment in athletes. PMID:24830292
Baracco, A; Coggiola, M; Discalzi, G; Perrelli, F; Romano, C
2009-01-01
Italian law on safety at work does not clarify specific levels of load for safe manual material handling. For this reason professionals appointed for safety need to define new target range value for the correct application of D.Lgs. 81/2008 law. Authors, discussing about indication of the national laws and international rules, suggest the assumption of a load of 25 and 20 kg as reference values for male and female adult and healthy workers. They also examine the graduation of the acceptable loads in relation to workers' age and the Lifting Index values to be adopted as action limit and exposure limit.
Determination of Vitamin E in Cereal Products and Biscuits by GC-FID.
Pasias, Ioannis N; Kiriakou, Ioannis K; Papakonstantinou, Lila; Proestos, Charalampos
2018-01-01
A rapid, precise and accurate method for the determination of vitamin E (α-tocopherol) in cereal products and biscuits has been developed. The uncertainty was calculated for the first time, and the methods were performed for different cereal products and biscuits, characterized as "superfoods". The limits of detection and quantification were calculated. The accuracy and precision were estimated using the certified reference material FAPAS T10112QC, and the determined values were in good accordance with the certified values. The health claims according to the daily reference values for vitamin E were calculated, and the results proved that the majority of the samples examined showed a percentage daily value higher than 15%.
Determination of Vitamin E in Cereal Products and Biscuits by GC-FID
Kiriakou, Ioannis K.; Papakonstantinou, Lila
2018-01-01
A rapid, precise and accurate method for the determination of vitamin E (α-tocopherol) in cereal products and biscuits has been developed. The uncertainty was calculated for the first time, and the methods were performed for different cereal products and biscuits, characterized as “superfoods”. The limits of detection and quantification were calculated. The accuracy and precision were estimated using the certified reference material FAPAS T10112QC, and the determined values were in good accordance with the certified values. The health claims according to the daily reference values for vitamin E were calculated, and the results proved that the majority of the samples examined showed a percentage daily value higher than 15%. PMID:29301245
Wätjen, U; Benedik, L; Spasova, Y; Vasile, M; Altzitzoglou, T; Beyermann, M
2010-01-01
In anticipation of new European requirements for monitoring radioactivity concentration in drinking water, IRMM organized an interlaboratory comparison on the determination of low levels of activity concentrations (about 10-100 mBq L(-1)) of the naturally occurring radionuclides (226)Ra, (228)Ra, (234)U and (238)U in three commercially available mineral waters. Using two or three different methods with traceability to the International System of Reference (SIR), the reference values of the water samples were determined prior to the proficiency test within combined standard uncertainties of the order of 3%-10%. An overview of radiochemical separation and measurement methods used by the 45 participating laboratories are given. The results of the participants are evaluated versus the reference values. Several of the participants' results deviate by more than a factor of two from the reference values, in particular for the radium isotopes. Such erroneous analysis results may lead to a crucial omission of remedial actions on drinking water supplies or to economic loss by an unjustified action. Copyright 2009 Elsevier Ltd. All rights reserved.
Quantity quotient reporting. A proposal for a standardized presentation of laboratory results.
Haeckel, Rainer; Wosniok, Werner
2009-01-01
Laboratory results are reported in different units (despite international recommendations for SI units) together with different reference limits, of which several exist for many quantities. It is proposed to adopt the concept of the intelligence quotient and to report quantitative results as a quantity quotient (QQ) in laboratory medicine. This quotient is essentially the difference (measured result minus mean or mode value of the reference interval) divided by the observed biological variation CV(o). Thus, all quantities are reported in the same unit system with the same reference limits (for convenience shifted to e.g., 80-120). The critical difference can also be included in this standardization concept. In this way the information of reference intervals and the original result are integrated into one combined value, which has the same format for all quantities suited for quotient reporting (QR). The proposal of QR does not interfere with neither the current concepts of traceability, SI units or method standardization. This proposal represents a further step towards harmonization of reporting. It provides simple values which can be interpreted easily by physicians and their patients.
Alkahtani, Shaea A
2017-03-21
The aim of this study was to determine reference values for sarcopenia indices using different methods in healthy Saudi young men. Participants included 232 Saudi men aged between 20 and 35 years. The study measured anthropometric indices, blood pressure, hand grip strength, and lean muscle mass using dual-energy X-ray absorptiometry (DXA), and bioelectrical impedance analysis (BIA) was performed using Inbody 770 and Tanita 980 devices. Using DXA, the mean value of appendicular lean mass divided by the height squared (ALM/ht 2 ) was found to be 8.97 ± 1.23 kg/m 2 ; hand grip strength measured 42.8 ± 7.6 kg. While the differences between DXA and BIA (Tanita) were significant for all parameters, the differences between DXA and Inbody values were significant only for ALM parameters. Inbody sensitivity and specificity values were 73% and 95.9%, respectively. The kappa (P = 0.80) and p values (P < 0.001) showed good agreement between Inbody and DXA, whereas Tanita sensitivity and specificity values were 54.2% and 98.3%, respectively. Bland-Altman plots for differences in lean mass values between Tanita, Inbody, and DXA methods showed very high bias for Tanita and DXA, with significant differences (P < 0.001). The cut-off values for sarcopenia indices for Saudi young men are different from those of other ethnicities. The use of tailored cut-off reference values instead of a general cut-off for BIA devices is recommended.
A tri-reference point theory of decision making under risk.
Wang, X T; Johnson, Joseph G
2012-11-01
The tri-reference point (TRP) theory takes into account minimum requirements (MR), the status quo (SQ), and goals (G) in decision making under risk. The 3 reference points demarcate risky outcomes and risk perception into 4 functional regions: success (expected value of x ≥ G), gain (SQ < × < G), loss (MR ≤ x < SQ), and failure (x < MR). The psychological impact of achieving or failing to achieve these reference points is rank ordered as MR > G > SQ. We present TRP assumptions and value functions and a mathematical formalization of the theory. We conducted empirical tests of crucial TRP predictions using both explicit and implicit reference points. We show that decision makers consider both G and MR and give greater weight to MR than G, indicating failure aversion (i.e., the disutility of a failure is greater than the utility of a success in the same task) in addition to loss aversion (i.e., the disutility of a loss is greater than the utility of the same amount of gain). Captured by a double-S shaped value function with 3 inflection points, risk preferences switched between risk seeking and risk aversion when the distribution of a gamble straddled a different reference point. The existence of MR (not G) significantly shifted choice preference toward risk aversion even when the outcome distribution of a gamble was well above the MR. Single reference point based models such as prospect theory cannot consistently account for these findings. The TRP theory provides simple guidelines for evaluating risky choices for individuals and organizational management. (PsycINFO Database Record (c) 2012 APA, all rights reserved).
The Stayhealthy bioelectrical impedance analyzer predicts body fat in children and adults.
Erceg, David N; Dieli-Conwright, Christina M; Rossuello, Amerigo E; Jensky, Nicole E; Sun, Stephanie; Schroeder, E Todd
2010-05-01
Bioelectrical impedance analysis (BIA) is a time-efficient and cost-effective method for estimating body composition. We hypothesized that there would be no significant difference between the Stayhealthy BC1 BIA and the selected reference methods when determining body composition. Thus, the purpose of the present study was to determine the validity of estimating percent body fat (%BF) using the Stayhealthy BIA with its most recently updated algorithms compared to the reference methods of dual-energy x-ray absorptiometry for adults and hydrostatic weighing for children. We measured %BF in 245 adults aged 18 to 80 years and 115 children aged 10 to 17 years. Body fat by BIA was determined using a single 50 kHz frequency handheld impedance device and proprietary software. Agreement between BIA and reference methods was assessed by Bland and Altman plots. Bland and Altman analysis for men, women, and children revealed good agreement between the reference methods and BIA. There was no significant difference by t tests between mean %BF by BIA for men, women, or children when compared to the respective reference method. Significant correlation values between BIA, and reference methods for all men, women, and children were 0.85, 0.88, and 0.79, respectively. Reliability (test-retest) was assessed by intraclass correlation coefficient and coefficient of variation. Intraclass correlation coefficient values were greater than 0.99 (P < .001) for men, women, and children with coefficient of variation values 3.3%, 1.8%, and 1.7%, respectively. The Stayhealthy BIA device demonstrated good agreement between reference methods using Bland and Altman analyses. Copyright 2010 Elsevier Inc. All rights reserved.
Stricker, Reto; Eberhart, Raphael; Chevailler, Marie-Christine; Quinn, Frank A; Bischof, Paul; Stricker, René
2006-01-01
During a normal menstrual cycle, serum levels of luteinizing hormone (LH), follicle-stimulating hormone (FSH), estradiol, and progesterone can vary widely between cycles for the same woman, as well as between different woman. Reliable reference values based on the local population are important for correct interpretation of laboratory results. The purpose of our study was to determine detailed reference values for these hormones throughout the menstrual cycle using the Abbott ARCHITECT system. From 20 volunteers (age 20-36 years) with normal cycles and no use of oral contraceptives, samples were taken every day during their cycle. Volunteers received three vaginal ultrasound examinations (days 10 and 13, and 1 or 2 days after ovulation) to measure follicular and corpus luteum development. Hormone levels were measured using the corresponding ARCHITECT assay and were synchronized to the LH peak. Median, and 5th and 95th percentile values were determined for each day of the cycle, as well as for early follicular (days -15 to -6), late follicular (days -5 to -1), LH peak (day 0), early luteal (+1 to +4), mid-luteal (days +5 to +9), and late luteal (days +10 to +14) phases of the cycle. Based on our data, we were able to establish detailed reference values for LH, FSH, estradiol, and progesterone, which should aid in the interpretation of results for these reproductive hormones in a variety of circumstances.
Wingate anaerobic test reference values for male power athletes.
Coppin, Erin; Heath, Edward M; Bressel, Eadric; Wagner, Dale R
2012-09-01
The aim of this study was to develop reference values for the Wingate Anaerobic Test (WAnT) for peak power (PP), mean power (MP), and fatigue index (FI) in NCAA Division IA male athletes. Seventy-seven athletes (age 20.8±1.8 y, mass 84.4±9.4 kg, height 183.9±6.2 cm) participating in American football (n=52) and track and field (n=25) performed a 30-s WAnT resisted at 0.085 kp/kg body mass (BM). Absolute mean (±SD) values for PP and MP were 1084.2±137.0 and 777.1±80.9 W, respectively, whereas values normalized to BM were 12.9±1.5 and 9.3±0.9 W/kg BM, respectively. Mean FI values were 49.1%±8.4%. PP outputs>13.6, 12.4-13.6, and <12.4 W/kg BM were classified as high, medium, and low, respectively. MP outputs>9.8, 9.0-9.8, and <9.0 W/kg BM were classified as high, medium, and low, respectively. The reference values developed in this study can be used in various athletic training and research programs to more accurately assess athletes' anaerobic fitness and to monitor changes resulting from anaerobic training.
Determination of ferrous and total iron in refractory spinels
DOE Office of Scientific and Technical Information (OSTI.GOV)
Amonette, James E.; Matyas, Josef
2015-12-30
Accurate and precise determination of the redox state of iron (Fe) in spinels presents a significant challenge due to their refractory nature. The resultant extreme conditions needed to obtain complete dissolution generally oxidize some of the Fe(II) initially present and thus prevent the use of colorimetric methods for Fe(II) measurements. To overcome this challenge we developed a hybrid oxidimetric/colorimetric approach, using Ag(I) as the oxidimetric reagent for determination of Fe(II) and 1,10-phenanthroline as the colorimetric reagent for determination of total Fe. This approach, which allows determination of Fe(II) and total Fe on the same sample, was tested on a seriesmore » of four geochemical reference materials and then applied to the analysis of Fe(Ni) spinel crystals isolated from simulated high-level-waste (HLW) glass and of several reagent magnetites. Results for the reference materials were in excellent agreement with published values, with the exception of USGS BIR-1, for which higher Fe(II) values and lower total Fe values were obtained. The Fe(Ni) spinels showed Fe(II) values at the detection limit (ca. 0.05 wt% Fe) and total Fe values slightly higher than obtained by total elemental analysis. For the magnetite samples, total Fe values were in agreement with reference results, but a wide range in Fe(II) values was obtained indicating various degrees of conversion to maghemite.« less
Chin, Kok-Yong; Ima-Nirwana, Soelaiman; Isa Naina, Mohamed; Norazlina, Mohamed; Ahmad Nazrun, Shuid; Norliza, Muhammad; Faizah, Othman; Farihah, H Suhaimi; Elvy Suhana, Mohd Ramli; Wan Zurinah, Wan Ngah
2012-01-01
Quantitative ultrasound (QUS) is a relatively easy, reliable, and safe method for bone status assessment, but reference data for Asian males remain scarce. Our study aimed to determine the values for one QUS parameter, the speed of sound (SOS) at the calcaneus, in Malaysian Chinese men and to determine the association between the SOS and several demographic characteristics, such as age, weight, height, and body mass index. Three hundred forty-eight Malaysian Chinese men aged 40 yr and older were recruited, and their calcaneal QUS value was determined using the CM-200 densitometer (Furuno Electric, Nishinomiya City, Japan). The results indicated a significant correlation between SOS and age, and multiple stepwise regression analysis indicated that age and height were important predictors of SOS. A significant reduction in SOS value was observed when men 60 yr and older were compared with men aged 40-49 yr. Compared with the reference data for Japanese males, Chinese men in Malaysia showed higher SOS values across all the age groups studied. In conclusion, there is an age-related decrease in SOS values in Malaysian Chinese men, and the SOS values established in this study can be used as a reference for future studies. Copyright © 2012 The International Society for Clinical Densitometry. Published by Elsevier Inc. All rights reserved.
Characterization of NIES CRM No. 23 Tea Leaves II for the determination of multielements.
Mori, Ikuko; Ukachi, Miyuki; Nagano, Kimiyo; Ito, Hiroyasu; Yoshinaga, Jun; Nishikawa, Masataka
2010-05-01
A candidate environmental certified reference material (CRM) for the determination of multielements in tea leaves and materials of similar matrix, NIES CRM No. 23 Tea Leaves II, has been developed and characterized by the National Institute for Environmental Studies (NIES), Japan. The origin of the material was tea leaves, which were ground, sieved through a 106-microm mesh, homogenized, and then subdivided into amber glass bottles. The results of homogeneity and stability tests indicated that the material was sufficiently homogeneous and stable for use as a reference material. The property values of the material were statistically determined based on chemical analyses by a network of laboratories using a wide range of methods. Sixteen laboratories participated in the characterization, and nine certified values and five reference values were obtained. These property values of the candidate CRM, which are expressed as mass fractions, were close to the median and/or mean values of the mass fractions of elements in various tea products. The candidate CRM is appropriate for use in analytical quality control and in the evaluation of methods used in the analysis of tea and materials of similar matrix.
Age-specific reference values for serum FSH and estradiol levels throughout the reproductive period.
Grisendi, Valentina; Spada, Elena; Argento, Cindy; Plebani, Maddalena; Milani, Silvano; Seracchioli, Renato; Volpe, Annibale; La Marca, Antonio
2014-06-01
High serum day 3 FSH levels are associated with poor ovarian reserve and reduced fertility, but the interpretation of FSH values according to age is still not univocal. The purpose of this study was to determine age-dependent reference values in women with regular menstrual cycles and FSH as a guide for specialists. The study was performed at the Department of Mother-Infant of a University-based tertiary care centre. One-hundred ninety-two healthy normal menstruating women were recruited for the study. All patients attended the department on menstrual cycle day 3 for a blood sample for FSH and estradiol determination. A linear relationship between FSH or estradiol serum levels and age was observed. The FSH level increased by 0.11 IU for every year of age (1 IU for every 9 years of age). The values of FSH and estradiol corresponding to the 5th, 25th, 50th, 75th, 95th centiles for any specific age have been calculated. Serum FSH levels need to be interpreted according to age-dependent reference values. Serum FSH levels on 95th centile for any age may represent a warning sign for reduced ovarian reserve.
Castro, André L; Dias, Mário; Reis, Flávio; Teixeira, Helena M
2014-10-01
Gamma-Hydroxybutyric Acid (GHB) is an endogenous compound with a story of clinical use, since the 1960's. However, due to its secondary effects, it has become a controlled substance, entering the illicit market for recreational and "dance club scene" use, muscle enhancement purposes and drug-facilitated sexual assaults. Its endogenous context can bring some difficulties when interpreting, in a forensic context, the analytical values achieved in biological samples. This manuscript reviewed several crucial aspects related to GHB forensic toxicology evaluation, such as its post-mortem behaviour in biological samples; endogenous production values, whether in in vivo and in post-mortem samples; sampling and storage conditions (including stability tests); and cut-off reference values evaluation for different biological samples, such as whole blood, plasma, serum, urine, saliva, bile, vitreous humour and hair. This revision highlights the need of specific sampling care, storage conditions, and cut-off reference values interpretation in different biological samples, essential for proper practical application in forensic toxicology. Copyright © 2014 Elsevier Ltd and Faculty of Forensic and Legal Medicine. All rights reserved.
Hemingway, B.S.
1982-01-01
Thermodynamic values for 110 uranium-bearing phases and 28 aqueous uranium solution species (298.15 K and l bar) are tabulated based upon evaluated experimental data (largely from calorimetric experiments) and estimated values. Molar volume data are given for most of the solid phases. Thermodynamic values for 16 uranium-bearing phases are presented for higher temperatures in the form of and as a supplement to U.S. Geological Survey Bulletin 1452 (Robie et al., 1979). The internal consistency of the thermodynamic values reported herein is dependent upon the reliability of the experimental results for several uranium phases that have been used as secondary calorimetric reference phases. The data for the reference phases and for those phases evaluated with respect to the secondary reference phases are discussed. A preliminary model for coffinite formation has been proposed together with an estimate of the free energy of formation of coffinite. Free energy values are estimated for several other uranium-bearing silicate phases that have been reported as secondary uranium phases associated with uranium ore deposits and that could be expected to develop wherever uranium is leached by groundwaters.
Vaquero-Martínez, Javier; Antón, Manuel; Ortiz de Galisteo, José Pablo; Cachorro, Victoria E; Wang, Huiqun; González Abad, Gonzalo; Román, Roberto; Costa, Maria João
2017-02-15
This paper shows the validation of integrated water vapor (IWV) measurements retrieved from the Ozone Monitoring Instrument (OMI), using as reference nine ground-based GPS stations in the Iberian Peninsula. The study period covers from 2007 to 2009. The influence of two factors, - solar zenith angle (SZA) and IWV -, on OMI-GPS differences was studied in detail, as well as the seasonal dependence. The pseudomedian of the relative differences is -1 ± 1% and the inter-quartile range (IQR) is 41%. Linear regressions calculated over each station show an acceptable agreement (R 2 up to 0.77). The OMI-GPS differences display a clear dependence on IWV values. Hence, OMI substantially overestimates the lower IWV data recorded by GPS (∼ 40%), while underestimates the higher IWV reference values (∼ 20%). In connection to this IWV dependence, the relative differences also show an evident SZA dependence when the whole range of IWV values are analyzed (OMI overestimates for high SZA values while underestimates for low values). Finally, the seasonal variation of the OMI-GPS differences is also associated with the strong IWV dependence found in this validation exercise. Copyright © 2016 Elsevier B.V. All rights reserved.
Connecting Swath Satellite Data With Imagery in Mapping Applications
NASA Astrophysics Data System (ADS)
Thompson, C. K.; Hall, J. R.; Penteado, P. F.; Roberts, J. T.; Zhou, A. Y.
2016-12-01
Visualizations of gridded science data products (referred to as Level 3 or Level 4) typically provide a straightforward correlation between image pixels and the source science data. This direct relationship allows users to make initial inferences based on imagery values, facilitating additional operations on the underlying data values, such as data subsetting and analysis. However, that same pixel-to-data relationship for ungridded science data products (referred to as Level 2) is significantly more challenging. These products, also referred to as "swath products", are in orbital "instrument space" and raster visualization pixels do not directly correlate to science data values. Interpolation algorithms are often employed during the gridding or projection of a science dataset prior to image generation, introducing intermediary values that separate the image from the source data values. NASA's Global Imagery Browse Services (GIBS) is researching techniques for efficiently serving "image-ready" data allowing client-side dynamic visualization and analysis capabilities. This presentation will cover some GIBS prototyping work designed to maintain connectivity between Level 2 swath data and its corresponding raster visualizations. Specifically, we discuss the DAta-to-Image-SYstem (DAISY), an indexing approach for Level 2 swath data, and the mechanisms whereby a client may dynamically visualize the data in raster form.
The influence of sex difference on self-reference effects in a male-dominated culture.
Song, Xuan; Shang, Rui; Bi, Qi; Zhang, Xin; Wu, Yanhong
2012-10-01
52 secondary school students from the Chaoshan, China, area, where males are highly valued, were examined for self-reference, mother-reference, and father-reference effects. Because the father is the primary role model in Chaoshan culture, it was predicted that male participants would demonstrate a father-reference effect while females would show a mother-reference effect. The results confirmed that females showed significant self-, mother-, and father-reference effects in terms of memory performance, while males showed only a significant father-reference effect and a marginally significant self-reference effect. This study highlights the importance of researching subcultures such as the Chaoshan subculture to gain a comprehensive understanding of self-construct.
Joseph, Gabby B.; McCulloch, Charles E.; Nevitt, Michael C.; Heilmeier, Ursula; Nardo, Lorenzo; Lynch, John A.; Liu, Felix; Baum, Thomas; Link, Thomas M.
2015-01-01
Objective The purpose of this study was 1) to establish a gender- and BMI-specific reference database of cartilage T2 values, and 2) to assess the associations between cartilage T2 values and gender, age, and BMI in knees without radiographic osteoarthritis or MRI-based (WORMS 0/1) evidence of cartilage degeneration. Design 481 subjects between the ages of 45-65 years with Kellgren-Lawrence Scores 0/1 in the study knee were selected from the Osteoarthritis Initiative database. Baseline morphologic cartilage 3T MRI readings (WORMS scoring) and T2 measurements (resolution=0.313mmx0.446mm) were performed in the medial femur, lateral femur, medial tibia, lateral tibia, and patella compartments. In order to create a reference database, a logarithmic transformation was applied to the data to obtain the 5th-95th percentile values for T2. Results Significant differences in mean cartilage T2 values were observed between joint compartments. Although females had slightly higher T2 values than males in a majority of compartments, the differences were only significant in the medial femur (p<0.0001). A weak positive association was seen between age and T2 in all compartments, and was most pronounced in the patella (3.27% increase in median T2/10 years, p=0.009). Significant associations between BMI and T2 were observed, and were most pronounced in the lateral tibia (5.33% increase in median T2/5 kg/m2 increase in BMI, p<0.0001), and medial tibia (4.81% increase in median T2 /5 kg/m2 increase in BMI, p<0.0001). Conclusions This study established the first reference database of T2 values in a large sample of morphologically normal cartilage plates in knees without radiographic knee osteoarthritis. While cartilage T2 values were weakly associated with age and gender, they had the highest correlations with BMI. PMID:25680652
Albumin and all-cause mortality risk in insurance applicants.
Fulks, Michael; Stout, Robert L; Dolan, Vera F
2010-01-01
Determine the relationship between albumin levels and all-cause mortality in life insurance applicants. By use of the Social Security Death Master File, mortality was determined in 1,704,566 insurance applicants for whom blood samples were submitted to Clinical Reference Laboratory. There were 53,211 deaths observed in this healthy adult population during a median follow-up of 12 years. Results were stratified by 6 age-sex groups: females: ages 20 to 49, 50 to 69 and 70+; and males: ages 20 to 49, 50 to 69 and 70+. The middle 50% of albumin values specific to each group was used as the reference band for that group. The mortality in bands representing other percentiles of albumin values higher and lower than the middle 50% were compared to the mortality in the reference band for each age-sex group. The highest percentile bands represent the lowest albumin values. Relative risk exceeded 150% of each age- and sex-specific reference band for all groups between the 90th and 95th percentile of albumin values. This translates into 150% risk thresholds at approximately 3.8 mg/dL for all females and for males 70+, and 4.1 mg/dL for males ages 20 to 69. Conversely, the highest 25% of albumin values were associated with approximately a 20% reduction in risk in males and a variable 10% reduction in risk in females when compared to the middle 50% of albumin values. Excluding those with total cholesterol < or = 160 mg/dL, or with AST, GGT or alkaline phosphatase elevations, had little impact on relative risk except at the lowest 0.5% of albumin values. When stratified by age and sex, albumin discriminated between all-cause mortality risks in healthy adults at all ages and across a wide range of values independent of other laboratory tests.
Guo, Wei; Song, Binbin; Shen, Junfei; Wu, Jiong; Zhang, Chunyan; Wang, Beili; Pan, Baishen
2015-08-25
To establish an indirect reference interval based on the test results of alanine aminotransferase stored in a laboratory information system. All alanine aminotransferase results were included for outpatients and physical examinations that were stored in the laboratory information system of Zhongshan Hospital during 2014. The original data were transformed using a Box-Cox transformation to obtain an approximate normal distribution. Outliers were identified and omitted using the Chauvenet and Tukey methods. The indirect reference intervals were obtained by simultaneously applying nonparametric and Hoffmann methods. The reference change value was selected to determine the statistical significance of the observed differences between the calculated and published reference intervals. The indirect reference intervals for alanine aminotransferase of all groups were 12 to 41 U/L (male, outpatient), 12 to 48 U/L (male, physical examination), 9 to 32 U/L (female, outpatient), and 8 to 35 U/L (female, physical examination), respectively. The absolute differences when compared with the direct results were all smaller than the reference change value of alanine aminotransferase. The Box-Cox transformation combined with the Hoffmann and Tukey methods is a simple and reliable technique that should be promoted and used by clinical laboratories.
Evolution or Entropy? Changing Reference/User Culture and the Future of Reference Librarians.
ERIC Educational Resources Information Center
Wilson, Myoung C.
2000-01-01
This article addresses issues that relate to the changing functional relationship between the reference librarian and the user, based on the observation that the advance of information technology, particularly the Internet, has altered the values, attitudes, and beliefs of library users, and, as a consequence, their micro-culture. (Author/LRW)
Rethinking Reference: Consistent Values, New Methods, and Different Tools
ERIC Educational Resources Information Center
Kendrick, Kaetrena Davis
2011-01-01
The core duties of the reference librarian inherently mandate that the work environment is not unlike a kaleidoscope: Students and faculty revolve within and around the library, and reference and public services workers do the same; every move temporarily redesigning the library, its collections, and even its very role on campus into something…
Reference States and Relative Values of Internal Energy, Enthalpy, and Entropy.
ERIC Educational Resources Information Center
Fredrickson, A. G.
1983-01-01
Discusses two reference states (pure chemical compounds and pure elements at specified condition of temperature and pressure) and the relation between these reference states for internal energy and enthalpy. Problem 5.11 from Modell and Reid's "Thermodynamics and its Applications" (p. 141) is used to apply the ideas discussed. (JN)
Assessment of femur length for fetal biometry in Malaysian pregnant women
NASA Astrophysics Data System (ADS)
Ramli, Ramzun Maizan; Adam, Noraina; Jaafar, Mohamad Suhaimi; Rahman, Azhar Abdul; Mustafa, Iskandar Shahrim; Radzi, Yasmin; Nordin, Suriani; Kamarudin, Izyani
2013-05-01
The fetal biometry assessment of femur length (FL) was developed in most countries to evaluate the foetus growth. In this study, the FL values for Malaysia population were determined. A prospective study was conducted and a number of 6501 pregnant women were involved with 12372 FL data were collected, performed at antenatal care clinic of Hospital Pulau Pinang, Malaysia. The SPSS software version 17 (regression analysis and paired sample t-test) were used for analysis. The FL values of this study were constructed and rapid FL growth rate in second trimester (2.59 mm/week) than third trimester (1.43 mm/week) was observed. By ethnicity, no significant difference (p ≥ 0.05) was found between the FL values for fetuses of Malay and Indian ethnic's mother (t = -2.042), however these two groups shows significantly (p < 0.05) higher values than those of Chinese ethnic's mother (t = 4.019, 4.083; accordingly). The FL values of Malaysian resulted as significant difference with the common reference FL values from USA and UK, and also with selected Asian populations (India, China, Korea and Japan). As conclusion, it is strong suggested that medical practitioner in Malaysia should avoid in using biometry references based on other population to avoid under- or over-estimation and for accurate assessment of the fetus growth. As this study involved local Malaysian fetuses, therefore the medical practitioner can use the FL values of this study as reference value for fetus biometry assessment in Malaysia.
Glycaemic index and glycaemic load values of a selection of popular foods consumed in Hong Kong.
Lok, Kris Y; Chan, Ruth; Chan, Dicken; Li, Liz; Leung, Grace; Woo, Jean; Lightowler, Helen J; Henry, C Jeya K
2010-02-01
The objective of the present paper is to provide glycaemic index (GI) and glycaemic load (GL) values for a variety of foods that are commonly consumed in Hong Kong and expand on the international GI table of Chinese foods. Fasted healthy subjects were given 50 g of available carbohydrate servings of a glucose reference, which was tested twice, and test foods of various brands of noodles (n 5), instant cereals (n 3) and breads (n 2), which were tested once, on separate occasions. For each test food, tests were repeated in ten healthy subjects. Capillary blood glucose was measured via finger-prick samples in fasting subjects ( - 5, 0 min) and at 15, 30, 45, 60, 90 and 120 min after the consumption of each test food. The GI of each test food was calculated geometrically by expressing the incremental area under the blood glucose response curve (IAUC) of each test food as a percentage of each subject's average IAUC for the reference food. GL was calculated as the product of the test food's GI and the amount of available carbohydrate in a reference serving size. The majority of GI values of foods tested were medium (a GI value of 56-69) to high (a GI value of 70 or more) and compared well with previously published values. More importantly, our dataset provides GI values of ten foods previously untested and presents values for foods commonly consumed in Hong Kong.
Armando García-Miranda, L; Contreras, I; Estrada, J A
2014-04-01
To determine reference values for full blood count parameters in a population of children 8 to 12 years old, living at an altitude of 2760 m above sea level. Our sample consisted of 102 individuals on whom a full blood count was performed. The parameters included: total number of red blood cells, platelets, white cells, and a differential count (millions/μl and %) of neutrophils, lymphocytes, monocytes, eosinophils and basophils. Additionally, we obtained values for hemoglobin, hematocrit, mean corpuscular volume, mean corpuscular hemoglobin, concentration of corpuscular hemoglobin and red blood cell distribution width. The results were statistically analyzed with a non-parametric test, to divide the sample in quartiles and obtain the lower and upper limits for our intervals. Moreover, the values for the intervals obtained from this analysis were compared to intervals obtained estimating+- 2 standard deviations above and below from our mean values. Our results showed significant differences compared to normal interval values reported for the adult Mexican population in most of the parameters studied. The full blood count is an important laboratory test used routinely for the initial assessment of a patient. Values of full blood counts in healthy individuals vary according to gender, age and geographic location; therefore, each population should have its own reference values. Copyright © 2013 Asociación Española de Pediatría. Published by Elsevier Espana. All rights reserved.
Suka, Machi; Yoshida, Katsumi; Kawai, Tadashi; Aoki, Yoshikazu; Yamane, Noriyuki; Yamauchi, Kuniaki
2005-07-01
To determine age- and sex-specific reference intervals for 10 health examination items in Japanese adults. Health examination data were accumulated from 24 different prefectural health service associations affiliated with the Japan Association of Health Service. Those who were non-smokers, drank less than 7 days/week, and had a body mass index of 18.5-24.9kg/m2 were sampled as a reference population (n = 737,538; 224,947 men and 512,591 women). After classified by age and sex, reference intervals for 10 health examination items (systolic blood pressure, diastolic blood pressure, total cholesterol, triglyceride, glucose, uric acid, AST, ALT, gamma-GT, and hemoglobin) were estimated using the parametric and nonparametric methods. In every item except for hemoglobin, men had higher reference intervals than women. Systolic blood pressure, total cholesterol, and glucose showed an upward trend in values with increasing age. Hemoglobin showed a downward trend in values with increasing age. Triglyceride, ALT, and gamma-GT reached a peak in middle age. Overall, parametric estimates showed narrower reference intervals than non-parametric estimates. Reference intervals vary with age and sex. Age- and sex-specific reference intervals may contribute to better assessment of health examination data.
Melamed, Alexander; Vittinghoff, Eric; Sriram, Usha; Schwartz, Ann V.; Kanaya, Alka M.
2010-01-01
The relationship between bone mineral density (BMD) and fracture risk is not well-established for non-white populations. There is no established BMD reference standard for South Asians. Dual energy x-ray absorptiometry (DXA) was used to measure BMD at total hip and lumbar spine in 150 US-based South Asian Indians. For each subject T-scores were calculated using BMD reference values based on US white, North Indian and South Indian populations, and the resulting WHO BMD category assignments were compared. Reference standards derived from Indian populations classified a larger proportion of US-based Indians as normal than did US white-based standards. The percentage of individuals reclassified when changing between reference standards varied by skeletal site and reference population origin, ranging from 13% (95% CI, 7–18%), when switching from US-white- to North Indian-based standard for total hip, to 40% (95% CI, 32–48%), when switching from US white to South Indian reference values for lumbar spine. These finding illustrate that choice of reference standard has a significant effect on the diagnosis of osteoporosis in South Asians, and underscore the importance of future research to quantify the relationship between BMD and fracture risk in this population. PMID:20663699
New Brazilian developmental curves and reference values for the Alberta infant motor scale.
Saccani, Raquel; Valentini, Nadia Cristina; Pereira, Keila R G
2016-11-01
The lack of Brazilian norms restrains the use of the Alberta Infant Motor Scale (AIMS) to precisely categorize infant motor development and discriminate infants with motor difficulties from typically developing infants. This study investigated reference values for the AIMS for Brazilian infants. Descriptive, cross-sectional study of infants from birth-to-18 months old. Trained professionals assessed infants in daycares, homes, and governmental health centers. Results showed increases in raw scores across age groups from 0- to 15-months of age. The stability of raw scores was observed after 16 months of age. Brazilian infants demonstrated lower scores in specific ages compared to the Canadian sample. Canadian and Brazilian children showed differences in motor performance scores across age and norms were established for Brazilian infants. This study highlights the importance to establish reference values for AIMS of infants across cultures. Copyright © 2016 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
van Loon, W. M. G. M.; Boon, A. R.; Gittenberger, A.; Walvoort, D. J. J.; Lavaleye, M.; Duineveld, G. C. A.; Verschoor, A. J.
2015-09-01
The Benthic Ecosystem Quality Index 2 (BEQI2) is the Dutch multi-metric index (MMI) for assessing the status and trend of benthic invertebrates in transitional and coastal waters for the Water Framework Directive (WFD). It contains the same indicators, i.e. species richness, Shannon index and AMBI, as in the multivariate m-AMBI. The latter MMI has been adopted by several European countries in the context of WFD implementation. In contrast to m-AMBI, the BEQI2 calculation procedure has been strongly simplified and consists of two steps, i.e. the separate indicator values are normalized using their long-term reference values resulting in three Ecological Quality Ratios (EQRs), which are subsequently averaged to give one BEQI2 value. Using this method only small numbers of samples need to be analysed by Dutch benthos laboratories annually, without the necessity to co-analyse a larger historical dataset. BEQI2 EQR values appeared to correlate quantitatively very well with m-AMBI EQR values. In addition, a data pooling procedure has been added to the BEQI2 tool which enables the pooling of small core samples (0.01-0.025 m2) into larger standardized data pools of 0.1 m2 in order to meet the data requirements of the AMBI indicator and to obtain comparable reference values. Furthermore, the BEQI2 tool automatically and efficiently converts species synonym names into standardized species names. The BEQI2 tool has been applied to all Dutch benthos data monitored by Rijkswaterstaat in the period of 1991-2010 in the transitional and coastal waters and salt lakes and these results are reported here for the first time. Reference values for species richness and Shannon index (99 percentile values) and AMBI reference values (1 percentile values) were estimated for all water body-ecotopes and are discussed. BEQI2 results for all these water bodies are discussed in view of natural and human pressures. The pressure sensitivity of the BEQI2 for sewage and dredging/dumping, via the state variables oxygen and suspended matter respectively, was demonstrated.
Final report on AFRIMETS.QM-K27: Determination of ethanol in aqueous matrix
NASA Astrophysics Data System (ADS)
Archer, Marcellé; Fernandes-Whaley, Maria; Visser, Ria; de Vos, Jayne; Prins, Sara; Rosso, Adriana; Ruiz de Arechavaleta, Mariana; Tahoun, Ibrahim; Kakoulides, Elias; Luvonga, Caleb; Muriira, Geoffrey; Naujalis, Evaldas; Zakaria, Osman Bin; Buzoianu, Mirella; Bebic, Jelena; Achour Mounir, Ben; Thanh, Ngo Huy
2013-01-01
From within AFRIMETS, the Regional Metrology Organization (RMO) for Africa, the RMO Key Comparison AFRIMETS.QM-K27 was coordinated by the National Metrology Institute of South Africa (NMISA) in 2011. Ten Metrology Institutes participated, comprising three AFRIMETS, two APMP, four EURAMET and one SIM participant. Participants were required to determine the forensic level concentration of two aqueous ethanol solutions that were gravimetrically prepared by the NMISA. Concentrations were expected to lie in the range of 0.1 mg/g to 5.0 mg/g. The accurate determination of ethanol content in aqueous medium is critical for regulatory forensic and trade purposes. The CCQM Organic Analysis Working Group has carried out several key comparisons (CCQM-K27 series) on the determination of ethanol in wine and aqueous matrices. Developing NMIs now had the opportunity to link to the earlier CCQM-K27 studies through the AFRIMETS.QM-K27 study. Gas chromatography coupled to flame ionisation or mass spectrometric detection was applied by eight of the participants, while three participants (including NMISA) applied titrimetry for the ethanol assay. The assigned reference value of the aqueous ethanol solutions was used to link AFRIMETS.QM-K27 to the CCQM-K27 key comparison reference value. The assigned reference values for AFRIMETS.QM-K27 Level 1 and Level 2 were (0.3249 ± 0.0021) mg/g (k = 2) and (4.6649 ± 0.0152) mg/g (k = 2), respectively. The reference values were determined using the purity-corrected gravimetric preparation values, while the standard uncertainty incorporated the gravimetric preparation and titrimetric homogeneity uncertainties. From previous CCQM-K27 studies, the expected spread (%CV) of higher order measurements of ethanol in aqueous medium is about 0.85% relative. In this study the CV for Level 1 is about 12% (10% with two outliers removed) and for Level 2 about 4%. Three of the ten laboratories submitted results within 1.5% of the gravimetric reference value for Level 1; four of the ten participating laboratories submitted mean results within 1.5% of the gravimetric reference value for Level 2. Two of the participating laboratories achieved mean results within 1.5% of the gravimetric reference value for both levels. Participants in the AFRIMETS-K27 study would therefore have benefited from a pilot study in which to test their measurement capability prior to participation in the key comparison. Several NMIs, however, will still be able to make new CMC claims based on their performance in this comparison. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
Update of the Dutch manual for costing studies in health care
Kanters, Tim A.; Bouwmans, Clazien A. M.; van der Linden, Naomi; Tan, Siok Swan; Hakkaart-van Roijen, Leona
2017-01-01
Objectives Dutch health economic guidelines include a costing manual, which describes preferred research methodology for costing studies and reference prices to ensure high quality studies and comparability between study outcomes. This paper describes the most important revisions of the costing manual compared to the previous version. Methods An online survey was sent out to potential users of the costing manual to identify topics for improvement. The costing manual was aligned with contemporary health economic guidelines. All methodology sections and parameter values needed for costing studies, particularly reference prices, were updated. An expert panel of health economists was consulted several times during the review process. The revised manual was reviewed by two members of the expert panel and by reviewers of the Dutch Health Care Institute. Results The majority of survey respondents was satisfied with content and usability of the existing costing manual. Respondents recommended updating reference prices and adding some particular commonly needed reference prices. Costs categories were adjusted to the international standard: 1) costs within the health care sector; 2) patient and family costs; and 3) costs in other sectors. Reference prices were updated to reflect 2014 values. The methodology chapter was rewritten to match the requirements of the costing manual and preferences of the users. Reference prices for nursing days of specific wards, for diagnostic procedures and nurse practitioners were added. Conclusions The usability of the costing manual was increased and parameter values were updated. The costing manual became integrated in the new health economic guidelines. PMID:29121647
Update of the Dutch manual for costing studies in health care.
Kanters, Tim A; Bouwmans, Clazien A M; van der Linden, Naomi; Tan, Siok Swan; Hakkaart-van Roijen, Leona
2017-01-01
Dutch health economic guidelines include a costing manual, which describes preferred research methodology for costing studies and reference prices to ensure high quality studies and comparability between study outcomes. This paper describes the most important revisions of the costing manual compared to the previous version. An online survey was sent out to potential users of the costing manual to identify topics for improvement. The costing manual was aligned with contemporary health economic guidelines. All methodology sections and parameter values needed for costing studies, particularly reference prices, were updated. An expert panel of health economists was consulted several times during the review process. The revised manual was reviewed by two members of the expert panel and by reviewers of the Dutch Health Care Institute. The majority of survey respondents was satisfied with content and usability of the existing costing manual. Respondents recommended updating reference prices and adding some particular commonly needed reference prices. Costs categories were adjusted to the international standard: 1) costs within the health care sector; 2) patient and family costs; and 3) costs in other sectors. Reference prices were updated to reflect 2014 values. The methodology chapter was rewritten to match the requirements of the costing manual and preferences of the users. Reference prices for nursing days of specific wards, for diagnostic procedures and nurse practitioners were added. The usability of the costing manual was increased and parameter values were updated. The costing manual became integrated in the new health economic guidelines.
77 FR 3377 - Direct Single Family Housing Loans and Grants
Federal Register 2010, 2011, 2012, 2013, 2014
2012-01-24
... will recapture the full subsidy from the value of the property. DATES: Effective: February 23, 2012.../deed in lieu of foreclosure cases, to reference the calculation for value appreciation under the... length sales contracts to establish market value for determining value appreciation. Agency appraisal...
Simpson, Aaron J; Potter, Julia M; Koerbin, Gus; Oakman, Carmen; Cullen, Louise; Wilkes, Garry J; Scanlan, Samuel L; Parsonage, William; Hickman, Peter E
2014-06-01
Many patients presenting to the emergency department (ED) for assessment of possible acute coronary syndrome (ACS) have low cardiac troponin concentrations that change very little on repeat blood draw. It is unclear if a lack of change in cardiac troponin concentration can be used to identify acutely presenting patients at low risk of ACS. We used the hs-cTnI assay from Abbott Diagnostics, which can detect cTnI in the blood of nearly all people. We identified a population of ED patients being assessed for ACS with repeat cTnI measurement who ultimately were proven to have no acute cardiac disease at the time of presentation. We used data from the repeat sampling to calculate total within-person CV (CV(T)) and, knowing the assay analytical CV (CV(A)), we could calculate within-person biological variation (CV(i)), reference change values (RCVs), and absolute RCV delta cTnI concentrations. We had data sets on 283 patients. Men and women had similar CV(i) values of approximately 14%, which was similar at all concentrations <40 ng/L. The biological variation was not dependent on the time interval between sample collections (t = 1.5-17 h). The absolute delta critical reference change value was similar no matter what the initial cTnI concentration was. More than 90% of subjects had a critical reference change value <5 ng/L, and 97% had values of <10 ng/L. With this hs-cTnI assay, delta cTnI seems to be a useful tool for rapidly identifying ED patients at low risk for possible ACS. © 2014 The American Association for Clinical Chemistry.
Arenas Berumen, Ever; Gómez Miranda, Luis Mario; Torres Balcázar, Elías; Padilla Alvarado, Victor Hugo; Renteria, Ivan
2014-10-31
Overweight and obesity in children in the Mexico-USA border have evolved differently to the rest of their respective countries. New reference values of cholesterol, triglycerides and glucose are required to treatment. To determine the reference values of cholesterol, triglycerides and glucose in Hispanic children between 6 and 11 years in the Mexico-USA border. A prospective, cross-sectional, descriptive and observational study. A population of Hispanic children between 6 and 11 years of both boys and girls, belonging to three public institutions in the cities of Ensenada and Chihuahua, randomly selected, were studied. The study variables were the levels of total cholesterol (TC), triglycerides (TG) and glucose (G). From 300 subjects studied just 54 children completed the study. Higher average values of TC (168.7 ± 27.2 mg / dl), TG (80.6 ± 48.4 mg / dl) and G (88.3 ± 8.9 mg / dl) were observed. An additional behavior was founded, never reported previously to the limit of the knowledge of the authors; glucose levels of the children studied decreased with increased of cholesterol and triglycerides. To discard a random relationship between the variables, the Pearson correlation coefficient was determined between waist circumference and BMI, verifying an inverse association with G and direct with the TG. The reference values for Hispanic children between 6 and 11 years living on the northern border of Mexico-USA differ with respect to the national average values of the countries studied. Further studies are needed in larger populations to confirm the trend ob served in glucose levels of normal children, overweight and obese. Copyright AULA MEDICA EDICIONES 2014. Published by AULA MEDICA. All rights reserved.
Trujillo, Logan T.; Stanfield, Candice T.; Vela, Ruben D.
2017-01-01
Converging evidence suggests that human cognition and behavior emerge from functional brain networks interacting on local and global scales. We investigated two information-theoretic measures of functional brain segregation and integration—interaction complexity CI(X), and integration I(X)—as applied to electroencephalographic (EEG) signals and how these measures are affected by choice of EEG reference. CI(X) is a statistical measure of the system entropy accounted for by interactions among its elements, whereas I(X) indexes the overall deviation from statistical independence of the individual elements of a system. We recorded 72 channels of scalp EEG from human participants who sat in a wakeful resting state (interleaved counterbalanced eyes-open and eyes-closed blocks). CI(X) and I(X) of the EEG signals were computed using four different EEG references: linked-mastoids (LM) reference, average (AVG) reference, a Laplacian (LAP) “reference-free” transformation, and an infinity (INF) reference estimated via the Reference Electrode Standardization Technique (REST). Fourier-based power spectral density (PSD), a standard measure of resting state activity, was computed for comparison and as a check of data integrity and quality. We also performed dipole source modeling in order to assess the accuracy of neural source CI(X) and I(X) estimates obtained from scalp-level EEG signals. CI(X) was largest for the LAP transformation, smallest for the LM reference, and at intermediate values for the AVG and INF references. I(X) was smallest for the LAP transformation, largest for the LM reference, and at intermediate values for the AVG and INF references. Furthermore, across all references, CI(X) and I(X) reliably distinguished between resting-state conditions (larger values for eyes-open vs. eyes-closed). These findings occurred in the context of the overall expected pattern of resting state PSD. Dipole modeling showed that simulated scalp EEG-level CI(X) and I(X) reflected changes in underlying neural source dependencies, but only for higher levels of integration and with highest accuracy for the LAP transformation. Our observations suggest that the Laplacian-transformation should be preferred for the computation of scalp-level CI(X) and I(X) due to its positive impact on EEG signal quality and statistics, reduction of volume-conduction, and the higher accuracy this provides when estimating scalp-level EEG complexity and integration. PMID:28790884
New guidelines for δ13C measurements
Coplen, Tyler B.; Brand, Willi A.; Gehre, Matthias; Groning, Manfred; Meijer, Harro A. J.; Toman, Blaza; Verkouteren, R. Michael
2006-01-01
Consistency of δ13C measurements can be improved 39−47% by anchoring the δ13C scale with two isotopic reference materials differing substantially in 13C/12C. It is recommended thatδ13C values of both organic and inorganic materials be measured and expressed relative to VPDB (Vienna Peedee belemnite) on a scale normalized by assigning consensus values of −46.6‰ to L-SVEC lithium carbonate and +1.95‰ to NBS 19 calcium carbonate. Uncertainties of other reference material values on this scale are improved by factors up to two or more, and the values of some have been notably shifted: the δ13C of NBS 22 oil is −30.03%.
Dosimetry and image quality assessment in a direct radiography system
Oliveira, Bruno Beraldo; de Oliveira, Marcio Alves; Paixão, Lucas; Teixeira, Maria Helena Araújo; Nogueira, Maria do Socorro
2014-01-01
Objective To evaluate the mean glandular dose with a solid state detector and the image quality in a direct radiography system, utilizing phantoms. Materials and Methods Irradiations were performed with automatic exposure control and polymethyl methacrylate slabs with different thicknesses to calculate glandular dose values. The image quality was evaluated by means of the structures visualized on the images of the phantoms. Results Considering the uncertainty of the measurements, the mean glandular dose results are in agreement with the values provided by the equipment and with internationally adopted reference levels. Results obtained from images of the phantoms were in agreement with the reference values. Conclusion The present study contributes to verify the equipment conformity as regards dose values and image quality. PMID:25741119
Articulating Leadership Values in Action: Conversation with School Leaders.
ERIC Educational Resources Information Center
Campbell, Carol; Gold, Anne; Lunt, Ingrid
2003-01-01
Interviews six experienced administrators--three men and three women--in England about their values and leadership styles. Finds, for example, that all appeared to combine different leadership styles with democratic values. (Contains 1 table and 55 references.)(PKP)
Reimbursement of pharmaceuticals: reference pricing versus health technology assessment.
Drummond, Michael; Jönsson, Bengt; Rutten, Frans; Stargardt, Tom
2011-06-01
Reference pricing and health technology assessment are policies commonly applied in order to obtain more value for money from pharmaceuticals. This study focussed on decisions about the initial price and reimbursement status of innovative drugs and discussed the consequences for market access and cost. Four countries were studied: Germany, The Netherlands, Sweden and the United Kingdom. These countries have operated one, or both, of the two policies at certain points in time, sometimes in parallel. Drugs in four groups were considered: cholesterol-lowering agents, insulin analogues, biologic drugs for rheumatoid arthritis and "atypical" drugs for schizophrenia. Compared with HTA, reference pricing is a relatively blunt instrument for obtaining value for money from pharmaceuticals. Thus, its role in making reimbursement decisions should be limited to drugs which are therapeutically equivalent. HTA is a superior strategy for obtaining value for money because it addresses not only price but also the appropriate indications for the use of the drug and the relation between additional value and additional costs. However, given the relatively higher costs of conducting HTAs, the most efficient approach might be a combination of both policies.
Boomsma, Martijn F; Slouwerhof, Inge; van Dalen, Jorn A; Edens, Mireille A; Mueller, Dirk; Milles, Julien; Maas, Mario
2015-11-01
The purpose of this research is to study the use of an internal reference standard for fat- and muscle as a replacement for an external reference standard with a phantom. By using a phantomless internal reference standard, Hounsfield unit (HU) measurements of various tissues can potentially be assessed in patients with a CT scan of the pelvis without an added phantom at time of CT acquisition. This paves the way for development of a tool for quantification of the change in tissue density in one patient over time and between patients. This could make every CT scan made without contrast available for research purposes. Fifty patients with unilateral metal-on-metal total hip replacements, scanned together with a calibration reference phantom used in bone mineral density measurements, were included in this study. On computed tomography scans of the pelvis without the use of intravenous iodine contrast, reference values for fat and muscle were measured in the phantom as well as within the patient's body. The conformity between the references was examined with the intra-class correlation coefficient. The mean HU (± SD) of reference values for fat for the internal- and phantom references were -91.5 (±7.0) and -90.9 (±7.8), respectively. For muscle, the mean HU (± SD) for the internal- and phantom references were 59.2 (±6.2) and 60.0 (±7.2), respectively. The intra-class correlation coefficients for fat and muscle were 0.90 and 0.84 respectively and show excellent agreement between the phantom and internal references. Internal references can be used with similar accuracy as references from an external phantom. There is no need to use an external phantom to asses CT density measurements of body tissue.
Morselli, Davide; Passini, Stefano
2015-11-01
In Crimes of obedience, Kelman and Hamilton argue that societies can be protected by the degeneration of authority only when citizenship is based on a strong values orientation. This reference to values may be the weakest point in their theory because they do not explicitly define these values. Nevertheless, their empirical findings suggest that the authors are referring to specific democratic principles and universal values (e.g., equality, fairness, harmlessness). In this article, a composite index known as the value-oriented citizenship (VOC) index is introduced and empirically analysed. The results confirm that the VOC index discriminates between people who relate to authority based on values rather than based on their role or on rules in general. The article discusses the utility of the VOC index to develop Kelman and Hamilton's framework further empirically as well as its implications for the analysis of the relationship between individuals and authority. Copyright © 2015 Elsevier Inc. All rights reserved.
Are personal values of importance in the stigmatization of people with mental illness?
Norman, Ross Mg; Sorrentino, Richard; Windell, Deborah; Manchanda, Rahul
2008-12-01
To investigate the relation of responses to the Schwartz Value Scale to preferred social distance to a person with either schizophrenia or depression. The influence of personal value priorities on discrimination has been investigated in several contexts, but seldom with reference to social distance towards those with mental illness. University students (n = 200) completed the Schwartz Value Scale, as well as a measure of beliefs about mental illness and preferred social distance with reference to a vignette describing a person with either schizophrenia or depression. Consistent with past findings, respondents indicated a preference for greater social distance for schizophrenia than depression, and beliefs about likelihood of socially inappropriate behaviour and danger were correlated with social distance. Self-transcendence value orientation was a significant independent predictor of preference for less social distance. These findings were not influenced by a social desirability bias. Value orientation makes a significant contribution to the prediction of social distance towards those with mental illness. Evaluation of value-based interventions to reduce such discrimination appears warranted.
Standardization for oxygen isotope ratio measurement - still an unsolved problem.
Kornexl; Werner; Gehre
1999-07-01
Numerous organic and inorganic laboratory standards were gathered from nine European and North American laboratories and were analyzed for their delta(18)O values with a new on-line high temperature pyrolysis system that was calibrated using Vienna standard mean ocean water (VSMOW) and standard light Antartic precipitation (SLAP) internationally distributed reference water samples. Especially for organic materials, discrepancies between reported and measured values were high, ranging up to 2 per thousand. The reasons for these discrepancies are discussed and the need for an exact and reliable calibration of existing reference materials, as well as for the establishment of additional organic and inorganic reference materials is stressed. Copyright 1999 John Wiley & Sons, Ltd.
A Survey of New Zealand Academic Reference Librarians: Current and Future Skills and Competencies
ERIC Educational Resources Information Center
Chawner, Brenda; Oliver, Gillian
2013-01-01
A survey of New Zealand academic subject/reference librarians was conducted in mid-2011 to identify the most highly valued knowledge, skills and competencies of reference librarians working in libraries in the tertiary sector. The project was part of an international collaborative project involving 13 countries. The results from New Zealand show…
Selecting reference cities for i-Tree Streets
E.G. McPherson
2010-01-01
The i-Tree Streets (formerly STRATUM) computer program quantifies municipal forest structure, function, and value using tree growth and geographic data from sixteen U.S. reference cities, one for each of sixteen climate zones. Selecting the reference city that best matches a subject city is problematic when the subject city is outside the U.S., lays on the border...
Edgell, S E; McCabe, S J; Breidenbach, W C; Neace, W P; LaJoie, A S; Abell, T D
2001-03-01
Different frames of reference can affect one's assessment of the value of hand transplantation. This can result in different yet rational decisions by different groups of individuals, especially patients and physicians. In addition, factors other than frames of reference can affect one's evaluation of hand transplantation, which can result in different decisions.
FreeSolv: A database of experimental and calculated hydration free energies, with input files
Mobley, David L.; Guthrie, J. Peter
2014-01-01
This work provides a curated database of experimental and calculated hydration free energies for small neutral molecules in water, along with molecular structures, input files, references, and annotations. We call this the Free Solvation Database, or FreeSolv. Experimental values were taken from prior literature and will continue to be curated, with updated experimental references and data added as they become available. Calculated values are based on alchemical free energy calculations using molecular dynamics simulations. These used the GAFF small molecule force field in TIP3P water with AM1-BCC charges. Values were calculated with the GROMACS simulation package, with full details given in references cited within the database itself. This database builds in part on a previous, 504-molecule database containing similar information. However, additional curation of both experimental data and calculated values has been done here, and the total number of molecules is now up to 643. Additional information is now included in the database, such as SMILES strings, PubChem compound IDs, accurate reference DOIs, and others. One version of the database is provided in the Supporting Information of this article, but as ongoing updates are envisioned, the database is now versioned and hosted online. In addition to providing the database, this work describes its construction process. The database is available free-of-charge via http://www.escholarship.org/uc/item/6sd403pz. PMID:24928188
Seguel, Mauricio; Muñoz, Francisco; Keenan, Alessandra; Perez-Venegas, Diego J; DeRango, Eugene; Paves, Hector; Gottdenker, Nicole; Müller, Ananda
2016-07-01
The establishment of clinical pathology baseline data is critical to evaluate temporal and spatial changes in marine mammal groups. Despite increased availability of studies on hematology and biochemistry of marine mammals, reference ranges are lacking for many populations, especially among fur seal species. During the austral summers of 2014 and 2015, we evaluated basic hematologic and biochemical parameters in clinically healthy, physically restrained South American fur seal ( Arctocephalus australis ) lactating females and 2-mo-old pups. We also assessed the temporal variation of hematology parameters on the pups during their first 2 mo of life. Reference ranges of lactating females were similar to those previously reported in other fur seal species. In the case of pups, reference ranges are similar to values previously reported in sea lion species. As expected, most biochemical and hematologic values differ significantly between adult females and pups. As in other otariids, South American fur seals pups are born with higher values of total red blood cells, hemoglobin, and packed cell volume, and lower numbers of total leukocytes, neutrophils, lymphocytes, and eosinophils. To the best of our knowledge, data on hematology reference values for South American fur seals has not been previously reported and is useful for continued health monitoring of this species, as well as for comparisons with other otariid groups.
HUGO: Hierarchical mUlti-reference Genome cOmpression for aligned reads
Li, Pinghao; Jiang, Xiaoqian; Wang, Shuang; Kim, Jihoon; Xiong, Hongkai; Ohno-Machado, Lucila
2014-01-01
Background and objective Short-read sequencing is becoming the standard of practice for the study of structural variants associated with disease. However, with the growth of sequence data largely surpassing reasonable storage capability, the biomedical community is challenged with the management, transfer, archiving, and storage of sequence data. Methods We developed Hierarchical mUlti-reference Genome cOmpression (HUGO), a novel compression algorithm for aligned reads in the sorted Sequence Alignment/Map (SAM) format. We first aligned short reads against a reference genome and stored exactly mapped reads for compression. For the inexact mapped or unmapped reads, we realigned them against different reference genomes using an adaptive scheme by gradually shortening the read length. Regarding the base quality value, we offer lossy and lossless compression mechanisms. The lossy compression mechanism for the base quality values uses k-means clustering, where a user can adjust the balance between decompression quality and compression rate. The lossless compression can be produced by setting k (the number of clusters) to the number of different quality values. Results The proposed method produced a compression ratio in the range 0.5–0.65, which corresponds to 35–50% storage savings based on experimental datasets. The proposed approach achieved 15% more storage savings over CRAM and comparable compression ratio with Samcomp (CRAM and Samcomp are two of the state-of-the-art genome compression algorithms). The software is freely available at https://sourceforge.net/projects/hierachicaldnac/with a General Public License (GPL) license. Limitation Our method requires having different reference genomes and prolongs the execution time for additional alignments. Conclusions The proposed multi-reference-based compression algorithm for aligned reads outperforms existing single-reference based algorithms. PMID:24368726
Transatlantic Comparison of CT Radiation Doses in the Era of Radiation Dose-Tracking Software.
Parakh, Anushri; Euler, Andre; Szucs-Farkas, Zsolt; Schindera, Sebastian T
2017-12-01
The purpose of this study is to compare diagnostic reference levels from a local European CT dose registry, using radiation-tracking software from a large patient sample, with preexisting European and North American diagnostic reference levels. Data (n = 43,761 CT scans obtained over the course of 2 years) for the European local CT dose registry were obtained from eight CT scanners at six institutions. Means, medians, and interquartile ranges of volumetric CT dose index (CTDI vol ), dose-length product (DLP), size-specific dose estimate, and effective dose values for CT examinations of the head, paranasal sinuses, thorax, pulmonary angiogram, abdomen-pelvis, renal-colic, thorax-abdomen-pelvis, and thoracoabdominal angiogram were obtained using radiation-tracking software. Metrics from this registry were compared with diagnostic reference levels from Canada and California (published in 2015), the American College of Radiology (ACR) dose index registry (2015), and national diagnostic reference levels from local CT dose registries in Switzerland (2010), the United Kingdom (2011), and Portugal (2015). Our local registry had a lower 75th percentile CTDI vol for all protocols than did the individual internationally sourced data. Compared with our study, the ACR dose index registry had higher 75th percentile CTDI vol values by 55% for head, 240% for thorax, 28% for abdomen-pelvis, 42% for thorax-abdomen-pelvis, 128% for pulmonary angiogram, 138% for renal-colic, and 58% for paranasal sinus studies. Our local registry had lower diagnostic reference level values than did existing European and North American diagnostic reference levels. Automated radiation-tracking software could be used to establish and update existing diagnostic reference levels because they are capable of analyzing large datasets meaningfully.
Reference Equations for Static Lung Volumes and TLCO from a Population Sample in Northern Greece.
Michailopoulos, Pavlos; Kontakiotis, Theodoros; Spyratos, Dionisios; Argyropoulou-Pataka, Paraskevi; Sichletidis, Lazaros
2015-02-14
Background: The most commonly used reference equations for the measurement of static lung volumes/capacities and transfer factor of the lung for CO (TL CO ) are based on studies around 30-40 years old with significant limitations. Objectives: Our aim was to (1) develop reference equations for static lung volumes and TL CO using the current American Thoracic Society/European Respiratory Society guidelines, and (2) compare the equations derived with those most commonly used. Methods: Healthy Caucasian subjects (234 males and 233 females) aged 18-91 years were recruited. All of them were healthy never smokers with a normal chest X-ray. Static lung volumes and TL CO were measured with a single-breath technique according to the latest guidelines. Results: Curvilinear regression prediction equations derived from the present study were compared with those that are most commonly used. Our reference equations in accordance with the latest studies show lower values for all static lung volume parameters and TL CO as well as a different way of deviation of those parameters (i.e. declining with age total lung capacity, TL CO age decline in both sex and functional residual capacity age rise in males). Conclusions: We suggest that old reference values of static lung volumes and TL CO should be updated, and our perception of deviation of some spirometric parameters should be revised. Our new reference curvilinear equations derived according to the latest guidelines could contribute to the updating by respiratory societies of old existing reference values and result in a better estimation of the lung function of contemporary populations with similar Caucasian characteristics. © 2015 S. Karger AG, Basel.
NASA Astrophysics Data System (ADS)
Nour, S.; Karam, L. R.; Inn, K. G. W.
2012-01-01
In 2005, the CCRI decided that a comparison undertaken from 2002 to 2008 by the NIST (under the auspices of the Inter-America Metrology System [SIM]) in the development of a new biota (Ocean Shellfish) standard reference material (SRM) was sufficiently well constructed that it could be converted into a supplementary comparison under CCRI(II), with comparison identifier CCRI(II)-S3. This would enable the comparison to be used to support calibration and measurement capability (CMC) claims for radionuclide measurements in reference materials (specifically, animal-based organic materials). Previous comparisons of radionuclides have been of single or multiple nuclides in non-complex matrices and results of such could not be extended to support capabilities to measure the same nuclides in reference materials. The results of this comparison have been used to determine the certified reference value of the SRM. The key comparison working group (KCWG) of the CCRI(II) has approved this approach as a mechanism to link all the results to certified 'reference values' in lieu of the key comparison reference value (KCRV) of these specified radionuclides in this type of matrix (shellfish) so as to support CMCs of similar materials submitted by the present participants. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCRI, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
Nocturnal oxygen saturation profiles of healthy term infants
Terrill, Philip Ian; Dakin, Carolyn; Hughes, Ian; Yuill, Maggie; Parsley, Chloe
2015-01-01
Objective Pulse oximetry is used extensively in hospital and home settings to measure arterial oxygen saturation (SpO2). Interpretation of the trend and range of SpO2 values observed in infants is currently limited by a lack of reference ranges using current devices, and may be augmented by development of cumulative frequency (CF) reference-curves. This study aims to provide reference oxygen saturation values from a prospective longitudinal cohort of healthy infants. Design Prospective longitudinal cohort study. Setting Sleep-laboratory. Patients 34 healthy term infants were enrolled, and studied at 2 weeks, 3, 6, 12 and 24 months of age (N=30, 25, 27, 26, 20, respectively). Interventions Full overnight polysomnography, including 2 s averaging pulse oximetry (Masimo Radical). Main outcome measurements Summary SpO2 statistics (mean, median, 5th and 10th percentiles) and SpO2 CF plots were calculated for each recording. CF reference-curves were then generated for each study age. Analyses were repeated with sleep-state stratifications and inclusion of manual artefact removal. Results Median nocturnal SpO2 values ranged between 98% and 99% over the first 2 years of life and the CF reference-curves shift right by 1% between 2 weeks and 3 months. CF reference-curves did not change with manual artefact removal during sleep and did not vary between rapid eye movement (REM) and non-REM sleep. Manual artefact removal did significantly change summary statistics and CF reference-curves during wake. Conclusions SpO2 CF curves provide an intuitive visual tool for evaluating whether an individual's nocturnal SpO2 distribution falls within the range of healthy age-matched infants, thereby complementing summary statistics in the interpretation of extended oximetry recordings in infants. PMID:25063836
Reference values of clinical chemistry and hematology parameters in rhesus monkeys (Macaca mulatta).
Chen, Younan; Qin, Shengfang; Ding, Yang; Wei, Lingling; Zhang, Jie; Li, Hongxia; Bu, Hong; Lu, Yanrong; Cheng, Jingqiu
2009-01-01
Rhesus monkey models are valuable to the studies of human biology. Reference values for clinical chemistry and hematology parameters of rhesus monkeys are required for proper data interpretation. Whole blood was collected from 36 healthy Chinese rhesus monkeys (Macaca mulatta) of either sex, 3 to 5 yr old. Routine chemistry and hematology parameters, and some special coagulation parameters including thromboelastograph and activities of coagulation factors were tested. We presented here the baseline values of clinical chemistry and hematology parameters in normal Chinese rhesus monkeys. These data may provide valuable information for veterinarians and investigators using rhesus monkeys in experimental studies.
An Evaluation Framework for Lossy Compression of Genome Sequencing Quality Values.
Alberti, Claudio; Daniels, Noah; Hernaez, Mikel; Voges, Jan; Goldfeder, Rachel L; Hernandez-Lopez, Ana A; Mattavelli, Marco; Berger, Bonnie
2016-01-01
This paper provides the specification and an initial validation of an evaluation framework for the comparison of lossy compressors of genome sequencing quality values. The goal is to define reference data, test sets, tools and metrics that shall be used to evaluate the impact of lossy compression of quality values on human genome variant calling. The functionality of the framework is validated referring to two state-of-the-art genomic compressors. This work has been spurred by the current activity within the ISO/IEC SC29/WG11 technical committee (a.k.a. MPEG), which is investigating the possibility of starting a standardization activity for genomic information representation.
Suzuki, Satoru; Midorikawa, Sanae; Fukushima, Toshihiko; Shimura, Hiroki; Ohira, Tetsuya; Ohtsuru, Akira; Abe, Masafumi; Shibata, Yoshisada; Yamashita, Shunichi; Suzuki, Shinichi
2015-01-01
Although several reports have defined normal thyroid volume depending on either age or body surface, there are no sequential reference values on childhood thyroid volume evaluated by using ultrasonography and epidemiological analysis in Japan. The aim of the present study was to establish updated reference values for thyroid volume by ultrasound examination and epidemiological analysis in 0-19 year-old Japanese children. It is based on a cross-sectional study conducted from October 9, 2011 to March 31, 2012. The subjects were 38,063 children who were examined by ultrasonography as the initial preliminary survey of the Fukushima Health Management Survey in October 9, 2011 to March 31, 2012. The width, thickness, and height of each lobe were measured and the volume of each lobe was calculated by the mean of the elliptical shape volume formula. The values of thyroid volume at the 2.5 and 97.5 percentiles of age and body surface area for each gender group were obtained from 0-19 year-old children. Positive correlation was observed between thyroid volume and either age or body surface. The right lobe was significantly larger than the left lobe. The thyroid volume in females was larger than that in males after adjusting body surface area. The reference values of childhood thyroid for each age or body surface area were obtained by this extensive survey using ultrasound. These reference values may be used to define the normal size of thyroid gland by echosonography in Japanese children, although thyroid volume may be affected by dimorphic factors such as sex hormones.
Han, Der-Sheng; Huang, Chi-Huang; Chen, Ssu-Yuan; Yang, Wei-Shiung
2017-01-01
Myostatin negatively regulates muscle growth, and its inhibition by suitable proteins can increase muscle bulk and exercise performance. However, the reference values of serum myostatin in athletes performing strength training are still lacking. A cross-sectional study recruiting28 male collegiate athletes performing strength training and 29 age-matched normal controls was conducted. The serum concentration of myostatin and insulin-like growth factor 1 (IGF-1), grip strength, and body composition were the main outcome measures. We used regression models to analyze the correlation between serum markers and the physiological parameters. The athlete group had greater height, weight, body mass index (BMI), fat mass percentage, fat-free mass, muscle mass, waist girth, grip strength, and estimated daily energy expenditure. The IGF-1 concentration was higher in the athlete group (324 ± 80 vs. 263 ± 134 ng/ml), but the myostatin levels did not differ (12.1 ± 3.7 vs. 12.4 ± 3.5 ng/ml). The reference value for IGF-1 among the healthy young males was 293 ± 114 ng/ml, correlated with age and height; the value for myostatin was 12.3 ± 3.6 ng/ml, correlated negatively with BMI, fat mass percentage, and waist girth after adjustment for age. Myostatin level is negatively related to fat percentage, and serum IGF-1 is positively related to height. The reference values could provide a basis for future doping-related study.
Lumeij, J T; Remple, J D; Remple, C J; Riddle, K E
1998-01-01
Reference values (inner limits of the percentiles P(2.5) and P(97.5) are given with a probability of 95%) for 21 plasma chemical variables were established in 79 peregrine falcons (Falco peregrinus). The following values were established: urea 0.8 to 3.9 mmol/l, creatinine 24 to 64 mumol/l, glucose 16.5 to 22.0 mmol/l, sodium 150 to 170 mmol/l, chloride 114 to 131 mmol/I, inorganic phosphorus 0.55 to 1.53 mmol/l, osmolal-ity 322 to 356 mOsmol/kg, alkaline phosphatase 31 to 121 IU/l, alanine aminotransferase 29 to 90 IU/l, aspartate aminotransferase 34 to 116 U/l, gamma glutamyl transferase 0 to 3 IU/l, lactate dehydrogenase 1008 to 2650 IU/l, creatine kinase 120 to 442 IU/l, cholinesterase 143 to 325 IU/1, glutamate dehydrogenase < 8 IU/l, total bile acids 5 to 69 mumol/l, uric acid 253 to 995 mumol/l, total protein 24 to 39 g/l, albumin 12.7 to 22.4 g/l. Reference values for the calculated albumin/globulin (A/G) ratio were 0.8 to 24. Based on previous studies, reference values for calcium were established using an adjustment formula using plasma total protein concentrations (before correction 1.86 to 2.49, after correction 1.97 to 2.46 mmol/l). Results of plasma potassium concentrations were erratic which was shown to be due to a time lag between sample collection and separation of plasma and cells.
Shojaei, Mir Hatef; Djalali, Mamhmoud; Siassi, Fereydoun; Khatami, Mohammad Reza; Boroumand, Mohammad Ali; Eshragian, Mohammad Reza
2009-07-01
High serum levels of lipoprotein(a) and homocysteine are risk factors of cardiovascular disease which are prevalent in patients on hemodialysis. Controversy exists about the effects of hydroxymethylglutaryl-CoA reductase inhibitors on serum lipoprotein(a) levels in patients on hemodialysis. Also, deficiency of some water soluble vitamins and administration of statins may raise serum levels of homocysteine in these patients. This study was designed to investigate serum levels of lipoprotein(a) and homocysteine in patients on hemodialysis who were taking a statin, vitamin B6, and folic acid. We investigated on 152 patients with maintenance hemodialysis who were taking atorvastatin or lovastatin, vitamin B6, and folic acid for at least 6 months. Their serum levels were obtained to measure lipoprotein(a) and homocysteine levels, as well as triglyceride, total cholesterol, high-density lipoprotein cholesterol, and low-density lipoprotein cholesterol. The mean serum values of total cholesterol, high-density lipoprotein cholesterol, and low-density lipoprotein cholesterol and triglyceride were significantly less than the maximum reference values (P < .001). The mean serum level of lipoprotein(a) was also less than the reference value (P = .009), but homocysteine level was 33% higher on average than the reference value (P < .001). Our study demonstrated that in our patients on hemodialysis, the mean serum level of homocysteine was about 30% higher than the reference value although they were receiving vitamin B6 and folic acid. Hence, they were still exposed to the risk of cardiovascular disease.
Tamukai, Kenichi; Takami, Yoshinori; Akabane, Yoshihito; Kanazawa, Yuko; Une, Yumi
2011-09-01
Bearded dragons are one of the most popular pet lizard species, and biochemical reference values are useful for health management of these reptiles. The objectives of this study were to measure plasma biochemical values in healthy captive bearded dragons, determine reference values, and evaluate the effects of sex and season on the results. Blood samples were collected from 100 captive healthy bearded dragons in Tokyo during the summer and winter. Plasma biochemical measurements were performed using a dry-slide automated biochemical analyzer. The data were then compared based on sex and season using 2-way ANOVA. Globulin, cholesterol, and calcium concentrations of females were higher in both summer and winter compared with the values obtained for males. Both males and females had higher uric acid concentrations in winter than in summer. When compared with males, females had a higher chloride concentration in summer and a higher total protein concentration and aspartate aminotransferase activity in winter. Potassium concentration in males was lower in winter than in summer, whereas in females cholesterol concentration was lower in winter than in summer. Biochemical values that differed based on sex and season in bearded dragons were similar to those in other lizards. These differences reflect physiologic differences in reproductive status in females and seasonal changes in temperature and hydration status. Plasma biochemical values established for bearded dragons in this study will be useful in the diagnostic assessment of captive animals. ©2011 American Society for Veterinary Clinical Pathology.
Chuang, Michael L; Gona, Philimon; Hautvast, Gilion L T F; Salton, Carol J; Breeuwer, Marcel; O'Donnell, Christopher J; Manning, Warren J
2014-04-01
To determine sex-specific reference values for left ventricular (LV) volumes, mass, and ejection fraction (EF) in healthy adults using computer-aided analysis and to examine the effect of age on LV parameters. We examined data from 1494 members of the Framingham Heart Study Offspring cohort, obtained using short-axis stack cine SSFP CMR, identified a healthy reference group (without cardiovascular disease, hypertension, or LV wall motion abnormality) and determined sex-specific upper 95th percentile thresholds for LV volumes and mass, and lower 5th percentile thresholds for EF using computer-assisted border detection. In secondary analyses, we stratified participants by age-decade and tested for linear trend across age groups. The reference group comprised 685 adults (423F; 61 ± 9 years). Men had greater LV volumes and mass, before and after indexation to common measures of body size (all P = 0.001). Women had greater EF (73 ± 6 versus 71 ± 6%; P = 0.0002). LV volumes decreased with greater age in both sexes, even after indexation. Indexed LV mass did not vary with age. LV EF and concentricity increased with greater age in both sexes. We present CMR-derived LV reference values. There are significant age and sex differences in LV volumes, EF, and geometry, whereas mass differs between sexes but not age groups. Copyright © 2013 Wiley Periodicals, Inc.
Chuang, Michael L.; Gona, Philimon; Hautvast, Gilion L.T.F.; Salton, Carol J.; Breeuwer, Marcel; O’Donnell, Christopher J.; Manning, Warren J.
2013-01-01
Purpose To determine sex-specific reference values for left ventricular (LV) volumes, mass and ejection fraction (EF) in healthy adults using computer-aided analysis and to examine the effect of age on LV parameters. Methods and Methods We examined data from 1494 members of the Framingham Heart Study Offspring cohort, obtained using short-axis stack cine SSFP CMR, identified a healthy reference group (without cardiovascular disease, hypertension, or LV wall motion abnormality) and determined sex-specific upper 95th percentile thresholds for LV volumes and mass, and lower 5th percentile thresholds for EF using computer-assisted border detection. In secondary analyses we stratified participants by age-decade and tested for linear trend across age groups. Results The reference group comprised 685 adults (423F; 61±9 years). Men had greater LV volumes and mass, before and after indexation to common measures of body size (all p<0.001). Women had greater EF (73±6 vs. 71±6%, p=0.0002). LV volumes decreased with greater age in both sexes, even after indexation. Indexed LV mass did not vary with age. LV EF and concentricity increased with greater age in both sexes. Conclusion We present CMR-derived LV reference values. There are significant age and sex differences in LV volumes, EF and geometry, while mass differs between sexes but not age groups. PMID:24123369
Age and sex variation in serum albumin concentration: an observational study.
Weaving, Gary; Batstone, Gifford F; Jones, Richard G
2016-01-01
In the UK, a common reference interval for serum albumin is widely used irrespective of age or sex. Implicit in this is that laboratories produce analytically similar results. This paper challenges the validity of this approach. A three-week collection of results sent to all primary care centres in England has been analysed by age, sex and laboratory. In all, 1,079,193 serum albumin reports were included in this analysis. The mean population serum albumin concentration increases to peak at around age 20 years and then decreases with increasing age. Values in females decrease more rapidly but become close to male values at 60 years. The variation between laboratories was large and potentially clinically significant. Reference intervals for serum albumin should be stratified by age and sex. Until there is greater methodological standardization, laboratories should determine their own reference intervals and not accept a single consensus reference interval. © The Author(s) 2015.
[Reference values of carbohydrates for the Venezuelan population].
Marisela, Granito; Suhey, Pérez; Yolmar, Valero; Colina, Jhoana
2013-12-01
An update of the nutritional recommendations for carbohydrate intake to the Venezuelan population was performed. For this work the concepts, data and methodology followed by other countrie's or groups of countries to obtain and document their own reference, in order to provide basic information to facilitate the establishment of reference values can be revised to better adapt to the Venezuelan population. The data correspond to healthy populations and taken as reference the recommendations of the Food and Nutrition Board of the U.S., the Committees of Experts on Energy and Protein FAO/WHO, among others. As a result of the literature review, the historical caloric formula of population and dietary patterns of Venezuela was propose the consumption of total carbohydrate intake between 50 and 60% of total caloric intake and simple sugars do not exceed 10% of intake. It is suggested to increase the consumption of vegetables, whole grains, legumes, vegetables and whole tropical fruits.
Langlois, Gary N.
1983-09-13
Measurement of the relative and actual value of acoustic characteristic impedances of an unknown substance, location of the interfaces of vertically-layered materials, and the determination of the concentration of a first material mixed in a second material. A highly damped ultrasonic pulse is transmitted into one side of a reference plate, such as a tank wall, where the other side of the reference plate is in physical contact with the medium to be measured. The amplitude of a return signal, which is the reflection of the transmitted pulse from the interface between the other side of the reference plate and the medium, is measured. The amplitude value indicates the acoustic characteristic impedance of the substance relative to that of the reference plate or relative to that of other tested materials. Discontinuities in amplitude with repeated measurements for various heights indicate the location of interfaces in vertically-layered materials. Standardization techniques permit the relative acoustic characteristic impedance of a substance to be converted to an actual value. Calibration techniques for mixtures permit the amplitude to be converted to the concentration of a first material mixed in a second material.
Reference interval computation: which method (not) to choose?
Pavlov, Igor Y; Wilson, Andrew R; Delgado, Julio C
2012-07-11
When different methods are applied to reference interval (RI) calculation the results can sometimes be substantially different, especially for small reference groups. If there are no reliable RI data available, there is no way to confirm which method generates results closest to the true RI. We randomly drawn samples obtained from a public database for 33 markers. For each sample, RIs were calculated by bootstrapping, parametric, and Box-Cox transformed parametric methods. Results were compared to the values of the population RI. For approximately half of the 33 markers, results of all 3 methods were within 3% of the true reference value. For other markers, parametric results were either unavailable or deviated considerably from the true values. The transformed parametric method was more accurate than bootstrapping for sample size of 60, very close to bootstrapping for sample size 120, but in some cases unavailable. We recommend against using parametric calculations to determine RIs. The transformed parametric method utilizing Box-Cox transformation would be preferable way of RI calculation, if it satisfies normality test. If not, the bootstrapping is always available, and is almost as accurate and precise as the transformed parametric method. Copyright © 2012 Elsevier B.V. All rights reserved.
Langlois, G.N.
1983-09-13
Measurement of the relative and actual value of acoustic characteristic impedances of an unknown substance, location of the interfaces of vertically-layered materials, and the determination of the concentration of a first material mixed in a second material are disclosed. A highly damped ultrasonic pulse is transmitted into one side of a reference plate, such as a tank wall, where the other side of the reference plate is in physical contact with the medium to be measured. The amplitude of a return signal, which is the reflection of the transmitted pulse from the interface between the other side of the reference plate and the medium, is measured. The amplitude value indicates the acoustic characteristic impedance of the substance relative to that of the reference plate or relative to that of other tested materials. Discontinuities in amplitude with repeated measurements for various heights indicate the location of interfaces in vertically-layered materials. Standardization techniques permit the relative acoustic characteristic impedance of a substance to be converted to an actual value. Calibration techniques for mixtures permit the amplitude to be converted to the concentration of a first material mixed in a second material. 6 figs.
Li, Ping; Li, Yang; Zhang, Ji; Yu, Shan-Fa; Wang, Zhi-Liang; Jia, Guang
2016-10-01
The concentration of chromium in the blood (CrB) has been confirmed as a biomarker for occupational chromium exposure, but its biological exposure indices (BEIs) are still unclear, so we collected data from the years 2006 and 2008 (Shandong Province, China) to analyze the relationship between the concentration of chromium in the air (CrA) of the workplaces and CrB to establish a reference value of CrB for biological monitoring of occupational workers. The levels of the indicators for nasal injury, kidney (β2 microglobulin (β2-MG)), and genetic damages (8-hydroxy-deoxyguanosine (8-OHdG) and micronucleus (MN)) were measured in all subjects of the year 2011 (Henan Province, China) to verify the protective effect in this reference value of CrB. Compared with the control groups, the concentrations of CrA and CrB in chromium exposed groups were significantly higher (P < 0.05). Positive correlations were found between CrA and CrB in chromium exposed groups (r 2006 = 0.60, r 2008 = 0.35) in the years 2006 and 2008. According to the occupational exposure limitation of CrA (50 μg/m(3), China), the reference value of CrB was recommended to 20 μg/L. The levels of nasal injury, β2-MG, 8-OhdG, and MN were not significantly different between the low chromium exposed group (CrB ≤ 20 μg/L) and the control group, while the levels of β2-MG, 8-OHdG, and MN were statistically different in the high chromium exposed group than that in the control group. This research proved that only in occupational workers, CrB could be used as a biomarker to show chromium exposure in the environment. The recommended reference value of CrB was 20 μg/L. © The Author(s) 2015.
Aprea, Maria Cristina; Scapellato, Maria Luisa; Valsania, Maria Carmen; Perico, Andrea; Perbellini, Luigi; Ricossa, Maria Cristina; Pradella, Marco; Negri, Sara; Iavicoli, Ivo; Lovreglio, Piero; Salamon, Fabiola; Bettinelli, Maurizio; Apostoli, Pietro
2017-04-21
Biological reference values (RVs) explore the relationships between humans and their environment and habits. RVs are fundamental in the environmental field for assessing illnesses possibly associated with environmental pollution, and also in the occupational field, especially in the absence of established biological or environmental limits. The Italian Society for Reference Values (SIVR) determined to test criteria and procedures for the definition of RVs to be used in the environmental and occupational fields. The paper describes the SIVR methodology for defining RVs of xenobiotics and their metabolites. Aspects regarding the choice of population sample, the quality of analytical data, statistical analysis and control of variability factors are considered. The simultaneous interlaboratory circuits involved can be expected to increasingly improve the quality of the analytical data. Examples of RVs produced by SIVR are presented. In particular, levels of chromium, mercury, ethylenethiourea, 3,5,6-trichloro-2-pyridinol, 2,5-hexanedione, 1-hydroxypyrene and t,t-muconic acid measured in urine and expressed in micrograms/g creatinine (μg/g creat) or micrograms/L (μg/L) are reported. With the proposed procedure, SIVR intends to make its activities known to the scientific community in order to increase the number of laboratories involved in the definition of RVs for the Italian population. More research is needed to obtain further RVs in different biological matrices, such as hair, nails and exhaled breath. It is also necessary to update and improve the present reference values and broaden the portfolio of chemicals for which RVs are available. In the near future, SIVR intends to expand its scientific activity by using a multivariate approach for xenobiotics that may have a common origin, and to define RVs separately for children who may be exposed more than adults and be more vulnerable.
Reference values of hip abductor torque among youth athletes: Influence of age, sex and sports.
Bittencourt, Natália Franco Netto; Santos, Thiago Ribeiro Teles; Gonçalves, Gabriela Gomes Pavan; Coelho, Amanda Priscila; Gomes, Bárbara Gonçalves Braz de Magalhães; Mendonça, Luciana De Michelis; Fonseca, Sérgio Teixeira
2016-09-01
(1) To determine the reference values of hip abductor torque in youth athletes; (2) To investigate the influence of sex, age and sports on hip abductors torque. Cross-sectional. Sports clubs. 301 volleyball, basketball and futsal athletes between 10 and 19 years of age. Mean value of three maximal isometric hip abductor torques, evaluated using a hand-held dynamometer. The mean values of maximal isometric hip abductor torque ranged from 1.03 to 1.50 Nm/kg. The dominant hip abductor torque values were greater in 15-19 years old (1.41 ± 0.27 Nm/kg) than in 10-14 years old (1.12 ± 0.31 Nm/kg). In addition, the hip abductor torque values were smaller in basketball players (1.15 ± 0.31 Nm/kg) than futsal (1.34 ± 0.37 Nm/kg) and volleyball players (1.28 ± 0.25 Nm/kg). The comparison of hip abductor torque between futsal and volleyball players revealed no difference. The hip abductor torque values were greater in male volleyball athletes (1.28 ± 0.25 Nm/kg) than female volleyball athletes (1.13 ± 0.22 Nm/kg). This study established reference values for maximal isometric hip abductor torque in youth volleyball, basketball and futsal athletes. In addition, the results demonstrated that sex, age and sports influenced hip abductor torque. Copyright © 2015 Elsevier Ltd. All rights reserved.
Serum free light chain reference values: a critical approach.
Altinier, Sara; Seguso, Mara; Zaninotto, Martina; Varagnolo, Mariacristina; Adami, Fausto; Angeli, Paolo; Plebani, Mario
2013-05-01
The clinical usefulness of serum free light chain (FLC) measurement in the management of patients with plasma cell proliferative disorders has been reported in several papers, and most clinical studies use the reference ranges declared by the manufacturer. The aim of the present study was to evaluate the reproducibility of FLCs immunoassay and to validate the reference range, before introducing it in routine setting. Internal quality control materials and a pool of fresh serum samples were used to evaluate imprecision; 162 fresh sera from healthy blood donors were analyzed to evaluate the reference range for FLCs. In order to verify the κ/λ FLC ratio, 43 sera from patients with polyclonal hypergammaglobulinemia were tested. The FLC immunoassay was performed using a nephelometer with the Freelite reagents. The imprecision studies performed using a serum pool tested with two different lots of reagents showed a mean CV of 16.09% for κFLC and of 16.72% for λFLC. Lower CV%s and different mean values were found by calculating the results from each specific lot separately, while different results were obtained using the control materials provided by the manufacturer. In reference subjects, the 2.5-97.5th percentiles were found to be 4.52-22.33 and 4.84-21.88mg/L for κFLC and λFLC, respectively. The range for κ/λ ratio (0.65-2.36) was validated with the values obtained from subjects with polyclonal hypergammaglobulinemia. In retesting 15 samples from blood donor subjects with a different lot of reagents, mean bias percentages of 17.60 for κFLC and 15.26 for λFLC were obtained. These findings confirm the lot-to-lot variability of the FLC assays also in the measurement of polyclonal light chains, as well as the need to carefully validate the reference values. Published by Elsevier Inc.
Mathis, Michael R.; Schechtman, Samuel A.; Engoren, Milo C.; Shanks, Amy M.; Thompson, Aleda; Kheterpal, Sachin; Tremper, Kevin K.
2016-01-01
Background Assessment of need for intravascular volume resuscitation remains challenging for anesthesiologists. Dynamic waveform indices, including systolic- and pulse-pressure variation (SPV/PPV), are demonstrated as reliable measures of fluid-responsiveness for mechanically ventilated patients. Despite widespread use, real-world reference distributions for SPV and PPV values have not been established for euvolemic intraoperative patients. The authors sought to establish SPV and PPV reference distributions and assess impact of modifying factors. Methods The authors evaluated adult patients undergoing general anesthetics for elective non-cardiac surgery. Median SPV and PPV over a 50-minute post-induction period were noted for each case. Modifying factors including body-mass index, age, ventilator settings, positioning, and hemodynamic management were studied via univariate and multivariable analyses. For SPV values, effects of data entry method (manually-entered versus automated recorded) were similarly studied. Results Among 1,791 cases, per-case median SPV and PPV values formed non-parametric distributions. For each distribution, median values, interquartile ranges, and reference intervals (2.5th-97.5th percentile) were respectively noted: these included manually-entered SPV (6.0, 5.0-7.0, 3.0-11.0 mmHg), automated SPV (4.7, 3.9-6.0, 2.2-10.4 mmHg), and automated PPV (7.0, 5.0-9.0, 2.0-16.0%). Non-supine positioning and preoperative beta blocker were independently associated with altered SPV and PPV, whereas ventilator tidal volume >8 mL/kg ideal body weight and peak inspiratory pressure >16 cm H2O demonstrated independent associations for SPV only. Conclusions This study establishes real-world SPV and PPV reference distributions absent in the current literature. Through a consideration of reference distributions and modifying factors, our study provides further evidence for assessing intraoperative volume status and fluid management therapies. PMID:27906705
Saravanabhavan, Gurusankar; Werry, Kate; Walker, Mike; Haines, Douglas; Malowany, Morie; Khoury, Cheryl
2017-03-01
Human biomonitoring reference values are statistical estimates that indicate the upper margin of background exposure to a given chemical at a given time. Nationally representative human biomonitoring data on 176 chemicals, including several metals and trace elements, are available in Canada from 2007 to 2013 through the Canadian Health Measures Survey (CHMS). In this work, we used a systematic approach based on the reference interval concept proposed by the International Federation of Clinical Chemistry and Laboratory Medicine and the International Union of Pure and Applied Chemistry to derive reference values (RV 95 s) for metals and trace elements. These RV 95 s were derived for blood and urine matrices in the general Canadian population based on the latest biomonitoring data from the CHMS. Biomarkers were chosen based on specific selection criteria, including widespread detection in Canadians (≥66% detection rate). Reference populations were created for each biomarker by applying appropriate exclusion criteria. Age and sex were evaluated as possible partitioning criteria and separate RV 95 s were derived for the sub-populations in cases where partitioning was deemed necessary. The RV 95 s for metals and trace elements in blood ranged from 0.18μg/L for cadmium in young children aged 3-5 years to 7900μg/L for zinc in males aged 20-79 years. In the case of urinary biomarkers, the RV 95 s ranged from 0.17μg/L for antimony in the total population aged 3-79 years to 1400mg/L for fluoride in adults aged 20-79 years. These RV 95 s represent the first set of reference values for metals and trace elements in the general Canadian population. We compare the RV 95 s from other countries where available and discuss factors that could influence such comparisons. Copyright © 2016 The Authors. Published by Elsevier GmbH.. All rights reserved.
Fan, Bo; Ng, Bennett K.; Shepherd, John A.
2017-01-01
Body Mass Index has traditionally been used as a measure of health, but Fat Mass Index (FMI) and Lean Mass Index (LMI) have been shown to be more predictive of mortality and health risk. Total body FMI and LMI reference curves have particularly been useful in quantifying sarcopenia and sarcopenic obesity. Research has shown regional composition has significant associations to health outcomes. We derived FMI and LMI reference curves of the regions of the body (leg, arm, and trunk) for 15,908 individuals in the 1999–2004 National Health and Nutrition Examination Survey data for each sex and ethnicity using the Lambda-Mu-Sigma (LMS) method and developed software to visualize this regional composition. These reference curves displayed differentiation between males and females during puberty and sharper limb LMI declines during late adulthood for males. For adults ages 30–50, females had 39%, 83%, and 47% larger arm, leg, and trunk FMI values than males, respectively. Males had 49%, 20%, and 15% higher regional LMI values than females for the arms, legs, and trunk respectively. The leg FMI and LMI of black females were 14% and 15% higher respectively than those of Hispanic and white females. White and Hispanic males had 37% higher trunk FMI values than black males. Hispanic females had 20% higher trunk FMI than white and black females. These data underscore the importance of accounting for sex and ethnicity in studies of regional composition. This study is the first to produce regional LMI and FMI reference tables and curves from the NHANES dataset. These reference curves provide a framework useful in studies and research involving sarcopenia, obesity, sarcopenic obesity, and other studies of compositional phenotypes. Further, the software tool we provide for visualizing regional composition will prove useful in monitoring progress in physical therapy, diets, or other attempts to attain healthier compositions. PMID:28346492
Qi, H.; Coplen, T.B.
2011-01-01
Accurate hydrogen isotopic measurements of keratin materials have been a challenge due to exchangeable hydrogen in the sample matrix and the paucity of appropriate isotopic reference materials for calibration. We found that the most reproducible δ2HVSMOW-SLAP and mole fraction of exchangeable hydrogen, x(H)ex, of keratin materials were measured with equilibration at ambient temperature using two desiccators and two different equilibration waters with two sets of the keratin materials for 6 days. Following equilibration, drying the keratin materials in a vacuum oven for 4 days at 60 °C was most critical. The δ2H analysis protocol also includes interspersing isotopic reference waters in silver tubes among samples in the carousel of a thermal conversion elemental analyzer (TC/EA) reduction unit. Using this analytical protocol, δ2HVSMOW-SLAP values of the non-exchangeable fractions of USGS42 and USGS43 human-hair isotopic reference materials were determined to be –78.5 ± 2.3 ‰ and –50.3 ± 2.8 ‰, respectively. The measured x(H)ex values of keratin materials analyzed with steam equilibration and N2 drying were substantially higher than those previously published, and dry N2 purging was unable to remove absorbed moisture completely, even with overnight purging. The δ2H values of keratin materials measured with steam equilibration were about 10 ‰ lower than values determined with equilibration in desiccators at ambient temperatures when on-line evacuation was used to dry samples. With steam equilibrations the x(H)ex of commercial keratin powder was as high as 28 %. Using human-hair isotopic reference materials to calibrate other keratin materials, such as hoof or horn, can introduce bias in δ2H measurements because the amount of absorbed water and the x(H)ex values may differ from those of unknown samples. Correct δ2HVSMOW-SLAP values of the non-exchangeable fractions of unknown human-hair samples can be determined with atmospheric moisture equilibration by normalizing with USGS42 and USGS43 human-hair reference materials when all materials have the same powder size.
Sharpless, K E; Gill, L M
2000-01-01
A number of food-matrix reference materials (RMs) are available from the National Institute of Standards and Technology (NIST) and from Agriculture Canada through NIST. Most of these materials were originally value-assigned for their elemental composition (major, minor, and trace elements), but no additional nutritional information was provided. Two of the materials were certified for selected organic constituents. Ten of these materials (Standard Reference Material [SRM] 1,563 Cholesterol and Fat-Soluble Vitamins in Coconut Oil [Natural and Fortified], SRM 1,566b Oyster Tissue, SRM 1,570a Spinach Leaves, SRM 1,974a Organics in Mussel Tissue (Mytilus edulis), RM 8,415 Whole Egg Powder, RM 8,418 Wheat Gluten, RM 8,432 Corn Starch, RM 8,433 Corn Bran, RM 8,435 Whole Milk Powder, and RM 8,436 Durum Wheat Flour) were recently distributed by NIST to 4 laboratories with expertise in food analysis for the measurement of proximates (solids, fat, protein, etc.), calories, and total dietary fiber, as appropriate. SRM 1846 Infant Formula was distributed as a quality control sample for the proximates and for analysis for individual fatty acids. Two of the materials (Whole Egg Powder and Whole Milk Powder) were distributed in an earlier interlaboratory comparison exercise in which they were analyzed for several vitamins. Value assignment of analyte concentrations in these 11 SRMs and RMs, based on analyses by the collaborating laboratories, is described in this paper. These materials are intended primarily for validation of analytical methods for the measurement of nutrients in foods of similar composition (based on AOAC INTERNATIONAL's fat-protein-carbohydrate triangle). They may also be used as "primary control materials" in the value assignment of in-house control materials of similar composition. The addition of proximate information for 10 existing reference materials means that RMs are now available from NIST with assigned values for proximates in 6 of the 9 sectors of the AOAC triangle. Five of these materials have values assigned for total dietary fiber-the first such information provided for materials available from NIST.
Monakhova, Yulia B; Kohl-Himmelseher, Matthias; Kuballa, Thomas; Lachenmeier, Dirk W
2014-11-01
A fast and reliable nuclear magnetic resonance spectroscopic method for quantitative determination (qNMR) of targeted molecules in reference materials has been established using the ERETIC2 methodology (electronic reference to access in vivo concentrations) based on the PULCON principle (pulse length based concentration determination). The developed approach was validated for the analysis of pharmaceutical samples in the context of official medicines control, including ibandronic acid, amantadine, ambroxol and lercanidipine. The PULCON recoveries were above 94.3% and coefficients of variation (CVs) obtained by quantification of different targeted resonances ranged between 0.7% and 2.8%, demonstrating that the qNMR method is a precise tool for rapid quantification (approximately 15min) of reference materials and medicinal products. Generally, the values were within specification (certified values) provided by the manufactures. The results were in agreement with NMR quantification using an internal standard and validated reference HPLC analysis. The PULCON method was found to be a practical alternative with competitive precision and accuracy to the classical internal reference method and it proved to be applicable to different solvent conditions. The method can be recommended for routine use in medicines control laboratories, especially when the availability and costs of reference compounds are problematic. Copyright © 2014 Elsevier B.V. All rights reserved.
University Students' Value Priorities and Emotional Empathy.
ERIC Educational Resources Information Center
Myyry, Liisa; Helkama, Klaus
2001-01-01
Presents a comparison of the Schwartz typology of values and the Spranger-Allport-Vernon typology. Investigates the differences among students in business, social science, and technology in emotional empathy and the relationships of value priorities and emotional empathy in different fields. Includes references. (CMK)
Gómez-Veiga, F; Silmi-Moyano, A; Günthner, S; Puyol-Pallas, M; Cózar-Olmo, J M
2014-06-01
Define and establish the reference values of the CAVIPRES-30 Questionnaire, a health related quality of life questionnaire specific for prostate cancer patients. The CAVIPRES-30 was administered to 2,630 males with prostate cancer included by 238 Urologist belonging to the Spanish National Healthcare System. Descriptive analysis on socio-demographic and clinical data were performed, and multivariate analyses were used to corroborate that stratification variables were statistically significantly and independently associated to the overall score of the questionnaire. The variables Time since diagnosis of the illness, whether the patient had a Stable partner or not, if he was, or not, undergoing Symptomatic treatment were statistically significantly and independently associated (P < .001) to the overall score of the questionnaire. The reference values table of the CAVIPRES-30 questionnaire is made up of different kinds of information of each patient profile: sample size, descriptive statistics with regard to the overall score, Cronbach's alpha value (between .791 and .875) and the questionnaire's values are reported by deciles. The results of this study contribute new proof as to the suitability and usefulness of the CAVIPRES-30 questionnaire as an instrument for assessing individually the quality of life of prostate cancer. Copyright © 2013 AEU. Published by Elsevier Espana. All rights reserved.
Using, Seeing, Feeling, and Doing Absolute Value for Deeper Understanding
ERIC Educational Resources Information Center
Ponce, Gregorio A.
2008-01-01
Using sticky notes and number lines, a hands-on activity is shared that anchors initial student thinking about absolute value. The initial point of reference should help students successfully evaluate numeric problems involving absolute value. They should also be able to solve absolute value equations and inequalities that are typically found in…
The Impact of Values on a Principal's Daily Activities.
ERIC Educational Resources Information Center
Moorhead, Roslyn; Nediger, William
1991-01-01
A two-year study of four effective secondary school principals suggests that a principal's actions can be represented by a value-based model (or Markov chain) in which beliefs and values lead to goals, activities, and outcomes. Findings show that no one value set brings about more effective leadership than another. (27 references) (MLH)
26 CFR 1.148-9 - Arbitrage rules for refunding issues.
Code of Federal Regulations, 2010 CFR
2010-04-01
... par bond, its stated principal amount, and in reference to any other bond, its present value. (3... allocated to the refunding of a separate prior issue is based on the present value of the refunded debt... satisfying the representative allocation method if that investment is valued at fair market value on the...
Strategies for Values Inquiry: An Exploratory Case Study
ERIC Educational Resources Information Center
Renger, Ralph; Bourdeau, Beth
2004-01-01
Values inquiry refers to systematic investigation of the values relevant to a program, including understanding those outcomes most prized by stakeholders. Although much attention has been given to stakeholder involvement, the literature on value inquiries per se as an approach is limited. This paper demonstrates how several of the steps used in…
VizieR Online Data Catalog: Monoceros star-forming region radial velocities (Costado+ 2018)
NASA Astrophysics Data System (ADS)
Costado, M. T.; Alfaro, E. J.
2018-03-01
The compiled data of each star. The columns RV + catalogue number are taken from VizieR (references below) and the column WEBDA is the median value calculated using all measurements taken from WEBDA database (references below for each cluster). We also show our identification number (ID), HD and HIP number, the Equatorial coordinates, the RV median value, which we will use in the kinematic analysis, and the distance calculated by Astraatmadja & Bailer-Jones (2017) using Gaia parallax. (1 data file).
Value assignment and uncertainty evaluation for single-element reference solutions
NASA Astrophysics Data System (ADS)
Possolo, Antonio; Bodnar, Olha; Butler, Therese A.; Molloy, John L.; Winchester, Michael R.
2018-06-01
A Bayesian statistical procedure is proposed for value assignment and uncertainty evaluation for the mass fraction of the elemental analytes in single-element solutions distributed as NIST standard reference materials. The principal novelty that we describe is the use of information about relative differences observed historically between the measured values obtained via gravimetry and via high-performance inductively coupled plasma optical emission spectrometry, to quantify the uncertainty component attributable to between-method differences. This information is encapsulated in a prior probability distribution for the between-method uncertainty component, and it is then used, together with the information provided by current measurement data, to produce a probability distribution for the value of the measurand from which an estimate and evaluation of uncertainty are extracted using established statistical procedures.
Assessing bioequivalence of generic modified-release antiepileptic drugs
Chang, Yi-Ting; Davit, Barbara; Gidal, Barry E.; Krauss, Gregory L.
2016-01-01
Objectives: The purpose of this study was to determine how closely generic modified-release antiepileptic drugs (MR-AEDs) resemble reference (brand) formulations by comparing peak concentrations (Cmax), total absorption (area under the curve [AUC]), time to Cmax (Tmax), intersubject variability, and food effects between generic and reference products. Methods: We tabulated Cmax and AUC data from the bioequivalence (BE) studies used to support the approvals of generic Food and Drug Administration–approved MR-AEDs. We compared differences in 90% confidence intervals of the generic/reference AUC and Cmax geometric mean ratios, and intersubject variability, Tmax and delivery profiles and food effects. Results: Forty-two MR-AED formulations were studied in 3,175 healthy participants without epilepsy in 97 BE studies. BE ratios for AUC and Cmax were similar between most generic and reference products: AUC ratios varied by >15% in 11.4% of BE studies; Cmax varied by >15% in 25.8% of studies. Tmax was more variable, with >30% difference in 13 studies (usually delayed in the fed compared to fasting BE studies). Generic and reference MR products had similar intersubject variability. Immediate-release AEDs showed less intersubject variability in AUC than did MR-AEDs. Conclusions: Most generic and reference MR-AEDs have similar AUC and Cmax values. Ratios for some products, however, are near acceptance limits and Tmax values may vary. Food effects are common with MR-AED products. High variability in pharmacokinetic values for once-a-day MR-AEDs suggests their major advantage compared to immediate-release AED formulations may be the convenience of less frequent dosing to improve adherence. PMID:27016518
Verma, Mascha; Khadapkar, Rashmi; Sahu, Priyadarshi Soumyaranjan; Das, Bibhu Ranjan
2006-09-01
An increase in the communication within the healthcare services, both nationally and internationally, has strengthened the need for harmonization of measurements and reference intervals in laboratory medicine. In the present report, the calculated reference interval for serum creatinine (sCr) levels of healthy normal individuals (n=1121) in different sex and age groups are compared with the established interval. The calculated reference interval for sCr level was 0.4-1.3 mg/dL and 0.6 to 1.3 mg/dL in the age groups of 21-40 and 41-60 years respectively. The difference between the mean sCr values in total males and total females (age range 21-60 years) was statistically significant (p<0.0001); When male and female subjects were analyzed age-group wise, the data showed a significant difference in mean sCr values (p<0.0001) in three age groups (21-30, 31-40 and 41-50 years) however, in older age group (51-60 years), the difference was non-significant (p=0.07). The reference ranges were 0.7-1.3 and 0.4-1.0 mg/dL for males and females respectively where the lower limit was 0.1-0.2 units less than that of standard limits. An increase in the mean value of sCr was observed particularly in females with an increase in age. Hence it is of interest to validate an age specific reference ranges for sCr in our population.
Khoury, Cheryl; Werry, Kate; Haines, Douglas; Walker, Mike; Malowany, Morie
2018-05-01
The Canadian Health Measures Survey collects nationally representative human biomonitoring data on a suite of chemicals and their metabolites, including many non-persistent chemicals. Data has been collected on non-persistent chemicals, including acrylamide, chlorophenols, environmental phenols and triclocarban, organophosphate insecticides, phthalates, polycyclic aromatic hydrocarbon, pyrethroid insecticides, and volatile organic compounds from 2009 to 2013. Using a systematic approach building on the reference interval concept proposed by the International Federation of Clinical Chemistry and Laboratory Medicine and the International Union of Pure and Applied Chemistry, we derive human biomonitoring reference values (RV 95 s) for these classes of non-persistent chemicals in blood and urine for the general Canadian population. RV 95 s were derived for biomarkers of non-persistent chemicals with widespread detection in Canadians (>66% detection rate). Samples with urinary creatinine levels outside the recommended range of 0.3-3.0 μg/L were excluded. Reference populations were constructed by applying smoking and fasting as exclusion criteria where appropriate. Age and sex were evaluated as possible partitioning criteria and separate RV 95 s were derived for sub-populations in cases where partitioning was deemed necessary. Reference values were derived for 40 biomarkers and represent the first set of RV 95 s for non-persistent chemicals in the general Canadian population. These values provide a measure of the upper margin of background exposure in the general population and can be compared against individual and population human biomonitoring data. RV 95 s can be used to by public health officials to identify individuals with high exposures, and by risk assessors and risk managers to identify atypical exposures or subpopulations with elevated exposures. Crown Copyright © 2018. Published by Elsevier GmbH. All rights reserved.
Coplen, T.B.; Friedman, Irving; O'Neil, J.R.
1984-01-01
According to U.S. Geological Survey records, a report prepared by R. Gonfiantini summarizing the findings and recommendations of the 1983 Advisory Group Meeting on Stable Isotope Reference Samples for Geochemical and Hydrologic Investigations held in Vienna does not accurately represent the consultants ' consensus on three important points. The consultants (1) recommended no value for the C02-H20 oxygen isotope fractionation factor, not the cited value of 1.04115, (2) adopted a value of 1.0309 rather than 1.03086 to relate the PDB and SMOW scales, and (3) adopted a firm 180 value of -2.20% for NBS-19 on the PDB scale rather than agreeing that this would be a tentative value subject to modification when more measurements in selected laboratories are available. (USGS)
A Tri-Reference Point Theory of Decision Making under Risk
ERIC Educational Resources Information Center
Wang, X. T.; Johnson, Joseph G.
2012-01-01
The tri-reference point (TRP) theory takes into account minimum requirements (MR), the status quo (SQ), and goals (G) in decision making under risk. The 3 reference points demarcate risky outcomes and risk perception into 4 functional regions: success (expected value of x greater than or equal to G), gain (SQ less than x less than G), loss (MR…
Kalkwarf, Heidi J.; Gilsanz, Vicente; Lappe, Joan M.; Oberfield, Sharon; Shepherd, John A.; Frederick, Margaret M.; Huang, Xiangke; Lu, Ming; Mahboubi, Soroosh; Hangartner, Thomas; Winer, Karen K.
2011-01-01
Context: Deficits in bone acquisition during growth may increase fracture risk. Assessment of bone health during childhood requires appropriate reference values relative to age, sex, and population ancestry to identify bone deficits. Objective: The objective of this study was to provide revised and extended reference curves for bone mineral content (BMC) and areal bone mineral density (aBMD) in children. Design: The Bone Mineral Density in Childhood Study was a multicenter longitudinal study with annual assessments for up to 7 yr. Setting: The study was conducted at five clinical centers in the United States. Participants: Two thousand fourteen healthy children (992 males, 22% African-Americans) aged 5–23 yr participated in the study. Intervention: There were no interventions. Main Outcome Measures: Reference percentiles for BMC and aBMD of the total body, lumbar spine, hip, and forearm were obtained using dual-energy x-ray absorptiometry for Black and non-Black children. Adjustment factors for height status were also calculated. Results: Extended reference curves for BMC and aBMD of the total body, total body less head, lumbar spine, total hip, femoral neck, and forearm for ages 5–20 yr were constructed relative to sex and age for Black and non-Black children. Curves are similar to those previously published for 7–17 year olds. BMC and aBMD values were greater for Black vs. non-Black children at all measurement sites. Conclusions: We provide here dual-energy x-ray absorptiometry reference data on a well-characterized cohort of 2012 children and adolescents. These reference curves provide the most robust reference values for the assessment and monitoring of bone health in children and adolescents in the literature to date. PMID:21917867
Watanabe, Ayumi; Inoue, Yusuke; Asano, Yuji; Kikuchi, Kei; Miyatake, Hiroki; Tokushige, Takanobu
2017-01-01
The specific binding ratio (SBR) was first reported by Tossici-Bolt et al. for quantitative indicators for dopamine transporter (DAT) imaging. It is defined as the ratio of the specific binding concentration of the striatum to the non-specific binding concentration of the whole brain other than the striatum. The non-specific binding concentration is calculated based on the region of interest (ROI), which is set 20 mm inside the outer contour, defined by a threshold technique. Tossici-Bolt et al. used a 50% threshold, but sometimes we couldn't define the ROI of non-specific binding concentration (reference region) and calculate SBR appropriately with a 50% threshold. Therefore, we sought a new method for determining the reference region when calculating SBR. We used data from 20 patients who had undergone DAT imaging in our hospital, to calculate the non-specific binding concentration by the following methods, the threshold to define a reference region was fixed at some specific values (the fixing method) and reference region was visually optimized by an examiner at every examination (the visual optimization method). First, we assessed the reference region of each method visually, and afterward, we quantitatively compared SBR calculated based on each method. In the visual assessment, the scores of the fixing method at 30% and visual optimization method were higher than the scores of the fixing method at other values, with or without scatter correction. In the quantitative assessment, the SBR obtained by visual optimization of the reference region, based on consensus of three radiological technologists, was used as a baseline (the standard method). The values of SBR showed good agreement between the standard method and both the fixing method at 30% and the visual optimization method, with or without scatter correction. Therefore, the fixing method at 30% and the visual optimization method were equally suitable for determining the reference region.
Choice of Reference Serum Creatinine in Defining Acute Kidney Injury.
Siew, Edward D; Matheny, Michael E
2015-01-01
The study of acute kidney injury (AKI) has expanded with the increasing availability of electronic health records and the use of standardized definitions. Understanding the impact of AKI between settings is limited by heterogeneity in the selection of reference creatinine to anchor the definition of AKI. In this mini-review, we discuss different approaches used to select reference creatinine and their relative merits and limitations. We reviewed the literature to obtain representative examples of published baseline creatinine definitions when pre-hospital data were not available, as well as literature evaluating the estimation of baseline renal function, using PubMed and reference back-tracing within known works. (1) Pre-hospital creatinine values are useful in determining reference creatinine, and in high-risk populations, the mean outpatient serum creatinine value 7-365 days before hospitalization closely approximates nephrology adjudication, (2) in patients without pre-hospital data, the eGFR 75 approach does not reliably estimate true AKI incidence in most at-risk populations, (3) using the lowest inpatient serum creatinine may be reasonable, especially in those with preserved kidney function, but may generously estimate AKI incidence and severity and miss community-acquired AKI that does not fully resolve, (4) using more specific definitions of AKI (e.g., KIDGO stages 2 and 3) may help to reduce the effects of misclassification when using surrogate values and (5) leveraging available clinical data may help refine the estimate of reference creatinine. Choosing reference creatinine for AKI calculation is important for AKI classification and study interpretation. We recommend obtaining data on pre-hospital kidney function, wherever possible. In studies where surrogate estimates are used, transparency in how they are applied and discussion that informs the reader of potential biases should be provided. Further work to refine the estimation of reference creatinine is needed. © 2015 S. Karger AG, Basel.
Reference values for Lactate Pro 2™ in fetal blood sampling during labor: a cross-sectional study.
Birgisdottir, Brynhildur Tinna; Holzmann, Malin; Varli, Ingela Hulthén; Graner, Sofie; Saltvedt, Sissel; Nordström, Lennart
2017-04-01
Lactate Pro™ (LP1) is the only lactate meter evaluated for fetal scalp blood sampling (FBS) in intrapartum use. The reference values for this meter are: normal value <4.2 mmol/L, preacidemia 4.2-4.8 mmol/L, and acidemia >4.8 mmol/L. The production of this meter has been discontinued. An updated version, Lactate Pro 2TM (LP2), has been launched and is shown to be differently calibrated. The aims of the study were to retrieve a conversion equation to convert lactate values in FBS measured with LP2 to an estimated value if using LP1 and to define reference values for clinical management when using LP2. A cross-sectional study was conducted at a university hospital in Sweden. A total of 113 laboring women with fetal heart rate abnormalities on cardiotocography (CTG) had FBS carried out. Lactate concentration was measured bedside with both LP1 and LP2 from the same blood sample capillary. A linear regression model was constructed to retrieve a conversion equation to convert LP2 values to LP1 values. LP2 measured higher values than LP1 in all analyses. We found that 4.2 mmol/L with LP1 corresponded to 6.4 mmol/L with LP2. Likewise, 4.8 mmol/L with LP1 corresponded to 7.3 mmol/L with LP2. The correlation between the analyses was excellent (Spearman's rank correlation, r=0.97). We recommend the following guidelines when interpreting lactate concentration in FBS with LP2: <6.4 mmol/L to be interpreted as normal, 6.4-7.3 mmol/L as preacidemia indicating a follow-up FBS within 20-30 min, and >7.3 mmol/L as acidemia indicating intervention.
ERIC Educational Resources Information Center
Arce, Alberto
2003-01-01
Both community development and sustainable livelihood approaches ignore value contestations that underlie people's interests and experiences. A case from Bolivia demonstrates that local values, social relations, actions, and language strategies must underlie policy and method in development. (Contains 28 references.) (SK)
Sub-Audible Speech Recognition Based upon Electromyographic Signals
NASA Technical Reports Server (NTRS)
Jorgensen, Charles C. (Inventor); Agabon, Shane T. (Inventor); Lee, Diana D. (Inventor)
2012-01-01
Method and system for processing and identifying a sub-audible signal formed by a source of sub-audible sounds. Sequences of samples of sub-audible sound patterns ("SASPs") for known words/phrases in a selected database are received for overlapping time intervals, and Signal Processing Transforms ("SPTs") are formed for each sample, as part of a matrix of entry values. The matrix is decomposed into contiguous, non-overlapping two-dimensional cells of entries, and neural net analysis is applied to estimate reference sets of weight coefficients that provide sums with optimal matches to reference sets of values. The reference sets of weight coefficients are used to determine a correspondence between a new (unknown) word/phrase and a word/phrase in the database.
Motivations and contents of parent-child value transmission.
Barni, Daniela; Donato, Silvia; Rosnati, Rosa; Danioni, Francesca
2017-01-01
This study focused on parents' motivations to transmit values to their adolescent children. According to Self-Determination Theory, controlled motivations (i.e., external and introjected)-which refer to doing something because it leads to approval or rewards-and autonomous motivations (i.e., identified and integrated)-which refer to doing something because it is perceived as inherently worthy-were examined. 325 Italian parental couples, with one child aged between 14 and 18 years, filled out a self-report questionnaire. Results showed that in value transmission, both parents were primarily moved by autonomous motivations, although for fathers, external motivations were more important than for mothers. Both paternal and maternal motivations resulted to be related with the values parents would like their children to endorse. In particular, the more parents felt volitional in transmitting values, the more they gave importance to self-transcendence in their children's socialization; the more parents were guided by controlled motivations, the more they would like their children to endorse conservation values. Implications of this research and its possible developments are discussed.
Todisco, T; Dottorini, M; Rossi, F; Baldoncini, A; Palumbo, R
1989-01-01
Peripheral airspace epithelial permeability (PAEP) to diethylentriaminopentacetate (DTPA), an index of pulmonary integrity, was measured in 3 groups of subjects for different purposes: (1) to establish vertical regional reference values; (2) to determine the physiological role of acute doubling of total pulmonary blood flow; (3) to quantify the pulmonary epithelial damage in smokers and the possibility of lung protection by an agent stimulating surfactant production. This study broadens previous knowledge of PAEP. First of all, regional reference values are given for young normal nonsmoking subjects and the existence of a vertical gradient of PAEP is confirmed. Furthermore, this study shows that this gradient is independent of the vertical blood flow gradient, since an acute increase of total blood flow in pneumonectomized patients does not modify the regional distribution of PAEP. Finally, it is confirmed that the cigarette smoker's lung is more permeable than the controls and that probably a drug-stimulating surfactant production gives some protection against damage due to chronic smoking.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Simbeck, D.J.
1993-12-31
Reference toxicant testing using juvenile freshwater mussels was conducted as part of the CR-ERP biomonitoring study of Clinch River sediments to assess the sensitivity of test organisms and the overall performance of the test. Tests were conducted using moderately hard synthetic water spiked with known concentrations of copper as copper sulfate. Toxicity testing of copper sulfate reference toxicant was conducted from May 12--21, 1993. The organisms used for testing were juvenile fresh-water mussels (Anodonta imbecillis). Results from this test showed an LC{sub 50} value of 1.12 mg Cu/L which is lower than the value of 2.02 mg Cu/L obtained inmore » a previous test. Too few tests have been conducted with copper as the toxicant to determine a normal range of values. Attachments to this report include: Toxicity test bench sheets and statistical analyses; Copper analysis request and results; and Personnel training documentation.« less
Neves, Laura A; Rodrigues, Janaína M; Daroda, Romeu J; Silva, Paulo R M; Ferreira, Alexandre A; Aranda, Donato A G; Eberlin, Marcos N; Fasciotti, Maíra
2015-11-15
Brazil is the largest producer of sugar cane bioethanol in the world. Isotope ratio mass spectrometry (IRMS) is the technique of choice to certify the origin/raw materials for ethanol production, but the lack of certified reference materials (CRMs) for accurate measurements of δ(13) C values traceable to Vienna Pee Dee Belemnite (VPDB), the international zero point for (13) C/(12) C measurements, certified and compatible with gas chromatography (GC)/IRMS instruments may compromise the accuracy of δ(13) C determinations. We evaluated the influence of methods for the calibration and normalization of raw δ(13) C values of ethanol samples. Samples were analyzed by GC/C/IRMS using two different GC columns. Different substances were used as isotopic standards for the working gas calibration. The δ(13) C values obtained with the three methods of normalization were statistically compared with those obtained with elemental analyzer (EA)/IRMS, since the δ(13) C results obtained using EA are traceable to VPDB via the NBS 22 reference material. It was observed that both the isotopic reference material for CO2 calibration and the GC column have a major effect on the δ(13) C measurements, leading to a bias of almost 2-3 ‰ in the δ(13) C values. All three methods of normalization were equivalent in performance, enabling an improvement in the GC/C/IRMS accuracy, compared with the EA/IRMS reference values for the samples. All the methods of CO2 calibration, chromatography and normalization presented in this work demonstrated several sources of traceability and accuracy loss for the determination of δ(13) C values in ethanol fuel samples by GC/C/IRMS. This work has also shown the importance of using proper CRMs traceable to VPBD that should be compatible and certified using GC/C/IRMS, ideally in a wide range of δ(13) C values. This is important not only for bioethanol fuel samples, but also for many analytes commonly analyzed by IRMS. Copyright © 2015 John Wiley & Sons, Ltd.
Assessment of international reference materials for isotope-ratio analysis (IUPAC Technical Report)
Brand, Willi A.; Coplen, Tyler B.; Vogl, Jochen; Rosner, Martin; Prohaska, Thomas
2014-01-01
Since the early 1950s, the number of international measurement standards for anchoring stable isotope delta scales has mushroomed from 3 to more than 30, expanding to more than 25 chemical elements. With the development of new instrumentation, along with new and improved measurement procedures for studying naturally occurring isotopic abundance variations in natural and technical samples, the number of internationally distributed, secondary isotopic reference materials with a specified delta value has blossomed in the last six decades to more than 150 materials. More than half of these isotopic reference materials were produced for isotope-delta measurements of seven elements: H, Li, B, C, N, O, and S. The number of isotopic reference materials for other, heavier elements has grown considerably over the last decade. Nevertheless, even primary international measurement standards for isotope-delta measurements are still needed for some elements, including Mg, Fe, Te, Sb, Mo, and Ge. It is recommended that authors publish the delta values of internationally distributed, secondary isotopic reference materials that were used for anchoring their measurement results to the respective primary stable isotope scale.
NASA Astrophysics Data System (ADS)
Eleftherakis, Dimitrios; Berger, Laurent; Le Bouffant, Naig; Pacault, Anne; Augustin, Jean-Marie; Lurton, Xavier
2018-06-01
The calibration of multibeam echosounders for backscatter measurements can be conducted efficiently and accurately using data from surveys over a reference natural area, implying appropriate measurements of the local absolute values of backscatter. Such a shallow area (20-m mean depth) has been defined and qualified in the Bay of Brest (France), and chosen as a reference area for multibeam systems operating at 200 and 300 kHz. The absolute reflectivity over the area was measured using a calibrated single-beam fishery echosounder (Simrad EK60) tilted at incidence angles varying between 0° and 60° with a step of 3°. This reference backscatter level is then compared to the average backscatter values obtained by a multibeam echosounder (here a Kongsberg EM 2040-D) at a close frequency and measured as a function of angle; the difference gives the angular bias applicable to the multibeam system for recorded level calibration. The method is validated by checking the single- and multibeam data obtained on other areas with sediment types different from the reference area.
Karbasy, Kimiya; Lin, Danny C C; Stoianov, Alexandra; Chan, Man Khun; Bevilacqua, Victoria; Chen, Yunqi; Adeli, Khosrow
2016-04-01
The CALIPER program is a national research initiative aimed at closing the gaps in pediatric reference intervals. CALIPER previously reported reference intervals for endocrine and special chemistry markers on Abbott immunoassays. We now report new pediatric reference intervals for immunoassays on the Beckman Coulter Immunoassay Systems and assess platform-specific differences in reference values. A total of 711 healthy children and adolescents from birth to <19 years of age were recruited from the community. Serum samples were collected for measurement of 29 biomarkers on the Beckman Coulter Immunoassay Systems. Statistically relevant age and/or gender-based partitions were determined, outliers removed, and reference intervals calculated in accordance with Clinical and Laboratory Standards Institute (CLSI) EP28-A3c guidelines. Complex profiles were observed for all 29 analytes, necessitating unique age and/or sex-specific partitions. Overall, changes in analyte concentrations observed over the course of development were similar to trends previously reported, and are consistent with biochemical and physiological changes that occur during childhood. Marked differences were observed for some assays including progesterone, luteinizing hormone and follicle-stimulating hormone where reference intervals were higher than those reported on Abbott immunoassays and parathyroid hormone where intervals were lower. This study highlights the importance of determining reference intervals specific for each analytical platform. The CALIPER Pediatric Reference Interval database will enable accurate diagnosis and laboratory assessment of children monitored by Beckman Coulter Immunoassay Systems in health care institutions worldwide. These reference intervals must however be validated by individual labs for the local pediatric population as recommended by CLSI.
Developing a competitive advantage in the market for radiology services.
Kropf, R; Szafran, A J
1988-01-01
This article describes how managers of outpatient diagnostic radiology services can develop a competitive advantage by increasing the value of services to patients and referring physicians. A method is presented to identify changes to services that increase their value. The method requires the definition of the "value chains" of patients and referring physicians. Particular attention is paid to the use of information systems technology to suggest and implement service changes. A narrow range of health services was selected because the approach requires a detailed understanding of consumers and how they use services. The approach should, however, be examined carefully by managers seeking to develop a competitive advantage for a wide range of health services.
Echocardiographic examinations of 60 African grey parrots and 30 other psittacine birds.
Pees, M; Straub, J; Krautwald-Junghanns, M-E
2004-07-17
The aim of this study was to establish reference values for the assessment of cardiac function in birds by measuring structures in the heart of healthy psittacine birds; 60 grey parrots, 10 Amazon parrots, 10 cockatoos and 10 Senegal parrots were anaesthetised with isoflurane and examined echocardiographically. The heart was visualised in two planes (vertical and horizontal views). Depending on the quality of the images, several dimensions of the heart could be measured and various parameters calculated. On the basis of these values, it was possible to establish reference values for each parrot genus. Some relative parameters showed no significant difference between the genera, independent of the bird's size.
Generation of mechanical oscillation applicable to vibratory rate gyroscopes
NASA Technical Reports Server (NTRS)
Lemkin, Mark A. (Inventor); Juneau, Thor N. (Inventor); Clark, William A. (Inventor); Roessig, Allen W. (Inventor)
2001-01-01
To achieve a drive-axis oscillation with improved frequency and amplitude stability, additional feedback loops are used to adjust force-feedback loop parameters. An amplitude-control loop measures oscillation amplitude, compares this value to the desired level, and adjusts damping of the mechanical sense-element to grow or shrink oscillation amplitude as appropriate. A frequency-tuning loop measures the oscillation frequency, compares this value with a highly stable reference, and adjusts the gain in the force-feedback loop to keep the drive-axis oscillation frequency at the reference value. The combined topology simultaneously controls both amplitude and frequency. Advantages of the combined topology include improved stability, fast oscillation start-up, low power consumption, and excellent shock rejection.
Sperm count. Do we need a new reference value?
Cardona Maya, Walter
2010-03-01
To evaluate the sperm count in fertile men, general population, and infertile men in different regions of the world. Sperm counts were recorded according to their fertility status, proven fertility, men recruited from an andrology/infertility clinic, or healthy men. The average of sperm count in the different studies is lower in infertile men that in fertile men (p>0.001) and in the general population (p>0.001). Based on this analysis the normal sperm count is about 65 million per mL. Using these reference value, only the 25% of the studies in infertile men are above this value, and the 75% studies with fertile men (>65 x 106 sperm/mL).
Polyfluorinated substances in abiotic standard reference materials
The National Institute of Standards and Technology (NIST) has a wide range of Standard Reference Materials (SRMs) which have values assigned for legacy organic pollutants and toxic elements. Existing SRMs serve as homogenous materials that can be used for method development, meth...
[Current problems in determining children's nutritional needs].
Koletzko, B; Toschke, A M; Von Kries, R
2004-03-01
Meeting children's nutritional needs is of fundamental importance for their immediate and later health, well-being, and performance. Age-adapted reference values of nutrient intake form the basis for analysis of the current situation and for policy planning, but for many nutrients they cannot be precisely defined due to inadequate scientific data. Therefore, such values are often extrapolated from adult reference values based on age-adapted mean body weight or body surface data, although such extrapolation does not reflect age-related physiological changes. There are considerable differences between various expert recommendations, in part also due to differences in definitions and underlying concepts for deriving reference values. Improvements and international harmonization are urgently needed. Nutritional needs of many children and adolescents are not adequately met at present. A particularly obvious indication is the epidemic-like increase of pediatric overweight and obesity, which could result in markedly increased prevalences of later metabolic syndrome, diabetes, and cardiovascular diseases. Contributing to increasing childhood obesity are low physical activity, changing eating culture and behavior, frequent consumption of high-fat foods with high energy density, and increasing portion sizes. Changes are urgently needed and might be achievable with close collaboration between scientists, public institutions, and industry.
Reference values for pulse oximetry at high altitude
Gamponia, M; Babaali, H; Yugar, F; Gilman, R
1998-01-01
OBJECTIVE—To determine reference values for oxygen saturation (SaO2) in healthy children younger than 5 years living at high altitude. DESIGN—One hundred and sixty eight children were examined for SaO2 at 4018 m during well child visits. Physiological state was also noted during the examination. RESULTS—The mean SaO2 was 87.3% (95% confidence intervals (CI) 86.7%, 87.9%) with a median value of 87.7%. A significant difference was observed in SaO2 between children younger than 1 year compared with older children, although the difference was no longer demonstrable when sleeping children were excluded. CONCLUSIONS—This study has provided a reference range of SaO2 values for healthy children under 5 years old so that pulse oximetry may be used as an adjunct in diagnosing acute respiratory infections. Younger children were also shown to have a lower mean SaO2 than older children living at high altitude, which suggests physiological adaptation to high altitude over time. In addition, sleep had a lowering effect on SaO2, although the clinical importance of this remains undetermined. PMID:9659095
Radiopacity Evaluation of Gutta-Percha Points in Thinner Samples than the ANSI/ADA Recommendation.
Petry, Bruna Lucian; Bodanezi, Augusto; Baldasso, Flávia Emi Razera; Delai, Débora; Larentis, Naiara Leites; Fontanella, Vania Regina Camargo; Kopper, Patrícia Maria Poli
2017-01-01
The aim of this study was to evaluate the radiopacity of different gutta-percha points (Endo Points®, Dentsply®, Tanari®, Meta®, Roeko® and Odous®) in samples of 1 mm thick as established by ANSI/ADA Specification #57 and ISO 6876/2001, in comparison with thinner samples. Twelve test specimens for each material, four for each thickness (0.3, 0.6, and 1 mm and diameter of 8 mm), were laminated and compressed between two polished glass plates until the desirable thickness. Digital radiographs were obtained along with a graduated aluminum stepwedge varying from 1 to 10 mm in thickness. The X-ray unit was set at 70 kVp, 10 mA and 0.4 s exposure time, at a focal distance of 36 cm. One calibrated observer quantified the average values of pixels with Adobe Photoshop® software. Data were analyzed using ANOVA and Tukey tests, at 5% significance level. At 0.6 and 1 mm thickness, all the tested materials showed radiopacity higher than 3 mm of aluminum (reference value). At 0.3 mm thickness, Odous and Tanari presented significantly less radiopacity than the reference, and the other materials showed similar radiopacity to the reference. The study concluded that the materials demonstrated different radiopacities and all had values above the minimum recommended by ANSI/ADA specification #57, being Odous and Tanari less radiopaque than the reference value in thinner samples (0.3mm).
EURRECA: development of tools to improve the alignment of micronutrient recommendations.
Matthys, C; Bucchini, L; Busstra, M C; Cavelaars, A E J M; Eleftheriou, P; Garcia-Alvarez, A; Fairweather-Tait, S; Gurinović, M; van Ommen, B; Contor, L
2010-11-01
Approaches through which reference values for micronutrients are derived, as well as the reference values themselves, vary considerably across countries. Harmonisation is needed to improve nutrition policy and public health strategies. The EURRECA (EURopean micronutrient RECommendations Aligned, http://www.eurreca.org) Network of Excellence is developing generic tools for systematically establishing and updating micronutrient reference values or recommendations. Different types of instruments (including best practice guidelines, interlinked web pages, online databases and decision trees) have been identified. The first set of instruments is for training purposes and includes mainly interactive digital learning materials. The second set of instruments comprises collection and interlinkage of diverse information sources that have widely varying contents and purposes. In general, these sources are collections of existing information. The purpose of the majority of these information sources is to provide guidance on best practice for use in a wider scientific community or for users and stakeholders of reference values. The third set of instruments includes decision trees and frameworks. The purpose of these tools is to guide non-scientists in decision making based on scientific evidence. This platform of instruments will, in particular in Central and Eastern European countries, contribute to future capacity-building development in nutrition. The use of these tools by the scientific community, the European Food Safety Authority, bodies responsible for setting national nutrient requirements and others should ultimately help to align nutrient-based recommendations across Europe. Therefore, EURRECA can contribute towards nutrition policy development and public health strategies.
Pursuit of communal values in an agentic manner: a way to happiness?
Abele, Andrea E
2014-01-01
The present research studies the association between traits, values, and life satisfaction. While values should influence the direction of an individual's goals and behavior, his/her traits impact effort-expenditure, efficiency, and persistence in goal-pursuit. We apply the framework of the "Big Two" of agency and communion (Bakan, 1966) for distinguishing the content of values and traits. While agentic content refers to qualities relevant for goal-attainment, such as assertiveness, competence or persistence, communal content refers to qualities relevant for the establishment and maintenance of social relationships, such as being friendly, helpful, or fair. We predict that high scores on communal values and high scores on agentic traits are associated with life satisfaction. We test these predictions in two studies conducted in different countries (Germany and Russia) with different cultural background. The findings support our reasoning: across both countries we find positive associations of communal values and agentic traits with life satisfaction; and individuals high in communal values and high in agentic traits are most satisfied with their lives. In Russia, the association of communal values with life satisfaction is moderated by agentic traits; in Germany, however, there is a main effect of communal values.
Pursuit of communal values in an agentic manner: a way to happiness?
Abele, Andrea E.
2014-01-01
The present research studies the association between traits, values, and life satisfaction. While values should influence the direction of an individual’s goals and behavior, his/her traits impact effort-expenditure, efficiency, and persistence in goal-pursuit. We apply the framework of the “Big Two” of agency and communion (Bakan, 1966) for distinguishing the content of values and traits. While agentic content refers to qualities relevant for goal-attainment, such as assertiveness, competence or persistence, communal content refers to qualities relevant for the establishment and maintenance of social relationships, such as being friendly, helpful, or fair. We predict that high scores on communal values and high scores on agentic traits are associated with life satisfaction. We test these predictions in two studies conducted in different countries (Germany and Russia) with different cultural background. The findings support our reasoning: across both countries we find positive associations of communal values and agentic traits with life satisfaction; and individuals high in communal values and high in agentic traits are most satisfied with their lives. In Russia, the association of communal values with life satisfaction is moderated by agentic traits; in Germany, however, there is a main effect of communal values. PMID:25477843
Yang, Jeong-Jin; Jeong, Dong-Hyuk; Lim, Yoon-Kyu
2018-04-19
Physiological characteristics, such as blood chemistry values, are valuable for evaluating the health of the animals. To our knowledge, these values have never been reported for the free-ranging Asiatic black bear ( Ursus thibetanus; ABB). Thus, 28 blood chemistry values from 50 free-ranging ABBs captured in Jirisan National Park, Republic of Korea, from 2005 to 2016 were evaluated. The aim of this study was to establish blood chemistry reference values for the free-ranging ABBs during both the hibernating and nonhibernating seasons. During hibernation, mean values of creatinine (CRE), total cholesterol, total protein (TP), albumin (ALB), triglycerides, and Mg were significantly higher than those during nonhibernation; however, mean values of blood urea nitrogen, urea nitrogen to creatinine (U/C) ratio, inorganic phosphorous (IP), aspartate aminotransferase, alanine aminotransferase, gamma-glutamyl transferase, lactate dehydrogenase (LDH), high-density lipoprotein cholesterol, and alkaline phosphatase (ALP) were significantly lower. Age differences (young vs. adult) were found in IP, LDH, TP, and ALB values during hibernation and in the U/C ratio, Ca, IP, ALP, creatine kinase myocardial band, CRE, total bilirubin, and uric acid values during nonhibernation. However, there were no sex differences (male vs. female).
Professional nursing values: A concept analysis.
Schmidt, Bonnie J; McArthur, Erin C
2018-01-01
The aim of this concept analysis is to clarify the meaning of professional nursing values. In a time of increasing ethical dilemmas, it is essential that nurses internalize professional values to develop and maintain a professional identity. However, nursing organizations and researchers provide different conceptions of professional nursing values, leading to a lack of clarity as to the meaning and attributes of this construct. Walker and Avant's (2011) method was used to guide an analysis of this concept. Resources published from 1973 to 2016 were identified via electronic databases and hand-searching of reference lists. A review of the literature was completed and the data were analyzed to identify uses of the concept; the defining attributes of the concept; borderline, related, contrary, and illegitimate examples; antecedents and consequences; and empirical referents. Professional nursing values were defined as important professional nursing principles of human dignity, integrity, altruism, and justice that serve as a framework for standards, professional practice, and evaluation. Further research is needed in the development and testing of professional nursing values theory, and the reassessment of values instruments. Core professional values that are articulated may help unify the profession and demonstrate the value of nursing to the public. © 2017 Wiley Periodicals, Inc.
A Brief History of Educational "Value-Added": How Did We Get to Where We Are?
ERIC Educational Resources Information Center
Saunders, Lesley
1999-01-01
Explains how and why the economics concept "value added" came to be used in an educational context, focusing on early usage in the United Kingdom. The term has been developed, used, and defined in various, conflicting ways. Some ambiguities cannot be eliminated. Value-added effectiveness measures involve value judgments. (44 references)…
Christiansen, Mark P; Klaff, Leslie J; Brazg, Ronald; Chang, Anna R; Levy, Carol J; Lam, David; Denham, Douglas S; Atiee, George; Bode, Bruce W; Walters, Steven J; Kelley, Lynne; Bailey, Timothy S
2018-03-01
Persistent use of real-time continuous glucose monitoring (CGM) improves diabetes control in individuals with type 1 diabetes (T1D) and type 2 diabetes (T2D). PRECISE II was a nonrandomized, blinded, prospective, single-arm, multicenter study that evaluated the accuracy and safety of the implantable Eversense CGM system among adult participants with T1D and T2D (NCT02647905). The primary endpoint was the mean absolute relative difference (MARD) between paired Eversense and Yellow Springs Instrument (YSI) reference measurements through 90 days postinsertion for reference glucose values from 40 to 400 mg/dL. Additional endpoints included Clarke Error Grid analysis and sensor longevity. The primary safety endpoint was the incidence of device-related or sensor insertion/removal procedure-related serious adverse events (SAEs) through 90 days postinsertion. Ninety participants received the CGM system. The overall MARD value against reference glucose values was 8.8% (95% confidence interval: 8.1%-9.3%), which was significantly lower than the prespecified 20% performance goal for accuracy (P < 0.0001). Ninety-three percent of CGM values were within 20/20% of reference values over the total glucose range of 40-400 mg/dL. Clarke Error Grid analysis showed 99.3% of samples in the clinically acceptable error zones A (92.8%) and B (6.5%). Ninety-one percent of sensors were functional through day 90. One related SAE (1.1%) occurred during the study for removal of a sensor. The PRECISE II trial demonstrated that the Eversense CGM system provided accurate glucose readings through the intended 90-day sensor life with a favorable safety profile.
Reference values of renal tubular function tests are dependent on age and kidney function.
Bech, Anneke P; Wetzels, Jack F M; Nijenhuis, Tom
2017-12-01
Electrolyte disorders due to tubular disorders are rare, and knowledge about validated clinical diagnostic tools such as tubular function tests is sparse. Reference values for tubular function tests are based on studies with small sample size in young healthy volunteers. Patients with tubular disorders, however, frequently are older and can have a compromised renal function. We therefore evaluated four tubular function tests in individuals with different ages and renal function. We performed furosemide, thiazide, furosemide-fludrocortisone, and desmopressin tests in healthy individuals aged 18-50 years, healthy individuals aged more than 50 years and individuals with compromised renal function. For each tubular function test we included 10 individuals per group. The responses in young healthy individuals were in line with previously reported values in literature. The maximal increase in fractional chloride excretion after furosemide was below the lower limit of young healthy individuals in 5/10 older subjects and in 2/10 patients with compromised renal function. The maximal increase in fractional chloride excretion after thiazide was below the lower limit of young healthy individuals in 6/10 older subjects and in 7/10 patients with compromised renal function. Median maximal urine osmolality after desmopressin was 1002 mosmol/kg H 2 O in young healthy individuals, 820 mosmol/kg H 2 O in older subjects and 624 mosmol/kg H 2 O in patients with compromised renal function. Reference values for tubular function tests obtained in young healthy adults thus cannot simply be extrapolated to older patients or patients with compromised kidney function. Larger validation studies are needed to define true reference values in these patient categories. © 2017 The Authors. Physiological Reports published by Wiley Periodicals, Inc. on behalf of The Physiological Society and the American Physiological Society.
NASA Astrophysics Data System (ADS)
Ardalan, A.; Safari, A.; Grafarend, E.
2003-04-01
A new ellipsoidal gravimetric-satellite altimetry boundary value problem has been developed and successfully tested. This boundary value problem has been constructed for gravity observables of the type (i) gravity potential (ii) gravity intensity (iii) deflection of vertical and (iv) satellite altimetry data. The developed boundary value problem is enjoying the ellipsoidal nature and as such can take advantage of high precision GPS observations in the set-up of the problem. The highlights of the solution are as follows: begin{itemize} Application of ellipsoidal harmonic expansion up to degree/order and ellipsoidal centrifugal field for the reduction of global gravity and isostasy effects from the gravity observable at the surface of the Earth. Application of ellipsoidal Newton integral on the equal area map projection surface for the reduction of residual mass effects within a radius of 55 km around the computational point. Ellipsoidal harmonic downward continuation of the residual observables from the surface of the earth down to the surface of reference ellipsoid using the ellipsoidal height of the observation points derived from GPS. Restore of the removed effects at the application points on the surface of reference ellipsoid. Conversion of the satellite altimetry derived heights of the water bodies into potential. Combination of the downward continued gravity information with the potential equivalent of the satellite altimetry derived heights of the water bodies. Application of ellipsoidal Bruns formula for converting the potential values on the surface of the reference ellipsoid into the geoidal heights (i.e. ellipsoidal heights of the geoid) with respect to the reference ellipsoid. Computation of the high-resolution geoid of Iran has successfully tested this new methodology!
[Analysis of the body composition of Spanish women with fibromyalgia].
Aparicio, Virginia A; Ortega, Francisco B; Heredia, José M; Carbonell-Baeza, Ana; Delgado-Fernández, Manuel
2011-01-01
To describe the anthropometric profile and body composition of women from Southern Spain diagnosed with fibromyalgia (FM) and to compare the observed values with values from other studies conducted on FM patients and with national reference values. The body composition of 104 women diagnosed with FM was assessed using an eight-electrode impedance meter. The reliability of the body composition measurement was tested in a randomly selected sub-sample (n=28). The reliability study showed a test-retest systematic error close to zero in most of the parameters studied. The women with FM who were studied had a mean weight of 71.3±13.4 kg, height of 158±6 cm, body mass index of 28.6±5.1 kg/m(2), body fat mass of 38.6±7.6%, total body water of 31.6±3.8 l and muscle mass of 23.4±3.0 kg. In general, there were no substantial differences in weight and body mass index between women with FM and those analyzed in other Spanish and European studies involving FM patients, nor when they were compared with regional or national reference values. However, the prevalence of obesity in the women with FM under study was 33.7%, a higher figure than that from the national reference data for obesity in similarly aged women (i.e. 26,4%). The results suggest that obesity is a common condition in women diagnosed with FM, its prevalence in this population being higher than the national reference values. This study provides detailed information about the body composition characteristics of women with FM. Copyright © 2010 Elsevier España, S.L. All rights reserved.
Code of Federal Regulations, 2010 CFR
2010-01-01
... radioactive waste within a designated boundary. Design bases means that information that identifies the... values or ranges of values chosen for controlling parameters as reference bounds for design. These values... events to be used for deriving design bases that will be based on consideration of historical data on the...
Code of Federal Regulations, 2012 CFR
2012-01-01
... radioactive waste within a designated boundary. Design bases means that information that identifies the... values or ranges of values chosen for controlling parameters as reference bounds for design. These values... events to be used for deriving design bases that will be based on consideration of historical data on the...
Code of Federal Regulations, 2014 CFR
2014-01-01
... radioactive waste within a designated boundary. Design bases means that information that identifies the... values or ranges of values chosen for controlling parameters as reference bounds for design. These values... events to be used for deriving design bases that will be based on consideration of historical data on the...
Code of Federal Regulations, 2011 CFR
2011-01-01
... radioactive waste within a designated boundary. Design bases means that information that identifies the... values or ranges of values chosen for controlling parameters as reference bounds for design. These values... events to be used for deriving design bases that will be based on consideration of historical data on the...
Code of Federal Regulations, 2013 CFR
2013-01-01
... radioactive waste within a designated boundary. Design bases means that information that identifies the... values or ranges of values chosen for controlling parameters as reference bounds for design. These values... events to be used for deriving design bases that will be based on consideration of historical data on the...
Cultural Values and Happiness: An East-West Dialogue.
ERIC Educational Resources Information Center
Lu, Luo; Gilmour, Robin; Kao, Shu-Fang
2001-01-01
Examines the relationships between cultural values and experiences of happiness in two samples focusing on university students in Taiwan (n=439) and the United Kingdom (n=344). Reports that the relationships between values and happiness were stronger in the Taiwanese sample. Includes references and an appendix. (CMK)
Calibration of helical tomotherapy machine using EPR/alanine dosimetry.
Perichon, Nicolas; Garcia, Tristan; François, Pascal; Lourenço, Valérie; Lesven, Caroline; Bordy, Jean-Marc
2011-03-01
Current codes of practice for clinical reference dosimetry of high-energy photon beams in conventional radiotherapy recommend using a 10 x 10 cm2 square field, with the detector at a reference depth of 10 cm in water and 100 cm source to surface distance (SSD) (AAPM TG-51) or 100 cm source-to-axis distance (SAD) (IAEA TRS-398). However, the maximum field size of a helical tomotherapy (HT) machine is 40 x 5 cm2 defined at 85 cm SAD. These nonstandard conditions prevent a direct implementation of these protocols. The purpose of this study is twofold: To check the absorbed dose in water and dose rate calibration of a tomotherapy unit as well as the accuracy of the tomotherapy treatment planning system (TPS) calculations for a specific test case. Both topics are based on the use of electron paramagnetic resonance (EPR) using alanine as transfer dosimeter between the Laboratoire National Henri Becquerel (LNHB) 60Co-gamma-ray reference beam and the Institut Curie's HT beam. Irradiations performed in the LNHB reference 60Co-gamma-ray beam allowed setting up the calibration method, which was then implemented and tested at the LNHB 6 MV linac x-ray beam, resulting in a deviation of 1.6% (at a 1% standard uncertainty) relative to the reference value determined with the standard IAEA TRS-398 protocol. HT beam dose rate estimation shows a difference of 2% with the value stated by the manufacturer at a 2% standard uncertainty. A 4% deviation between measured dose and the calculation from the tomotherapy TPS was found. The latter was originated by an inadequate representation of the phantom CT-scan values and, consequently, mass densities within the phantom. This difference has been explained by the mass density values given by the CT-scan and used by the TPS which were not the true ones. Once corrected using Monte Carlo N-Particle simulations to validate the accuracy of this process, the difference between corrected TPS calculations and alanine measured dose values was then found to be around 2% (with 2% standard uncertainty on TPS doses and 1.5% standard uncertainty on EPR measurements). Beam dose rate estimation results were found to be in good agreement with the reference value given by the manufacturer at 2% standard uncertainty. Moreover, the dose determination method was set up with a deviation around 2% (at a 2% standard uncertainty).
2003-01-01
Data are not readily available on the accuracy of one of the most commonly used home blood glucose meters, the One Touch Ultra (LifeScan, Milpitas, California). The purpose of this report is to provide information on the accuracy of this home glucose meter in children with type 1 diabetes. During a 24-h clinical research center stay, the accuracy of the Ultra meter was assessed in 91 children, 3-17 years old, with type 1 diabetes by comparing the Ultra glucose values with concurrent reference serum glucose values measured in a central laboratory. The Pearson correlation between the 2,068 paired Ultra and reference values was 0.97, with the median relative absolute difference being 6%. Ninety-four percent of all Ultra values (96% of venous and 84% of capillary samples) met the proposed International Organisation for Standardisation (ISO) standard for instruments used for self-monitoring of glucose when compared with venous reference values. Ninety-nine percent of values were in zones A + B of the Modified Error Grid. A high degree of accuracy was seen across the full range of glucose values. For 353 data points during an insulin-induced hypoglycemia test, the Ultra meter was found to have accuracy that was comparable to concurrently used benchmark instruments (Beckman, YSI, or i-STAT); 95% and 96% of readings from the Ultra meter and the benchmark instruments met the proposed ISO criteria, respectively. These results confirm that the One Touch Ultra meter provides accurate glucose measurements for both hypoglycemia and hyperglycemia in children with type 1 diabetes.
19 CFR 207.68 - Final comments on information.
Code of Federal Regulations, 2010 CFR
2010-04-01
... comment may address the accuracy, reliability, or probative value of such information by reference to... INVESTIGATIONS OF WHETHER INJURY TO DOMESTIC INDUSTRIES RESULTS FROM IMPORTS SOLD AT LESS THAN FAIR VALUE OR FROM...
NASA Astrophysics Data System (ADS)
Gang, Zhang; Fansong, Meng; Jianzhong, Wang; Mingtao, Ding
2018-02-01
Determining magnetotelluric impedance precisely and accurately is fundamental to valid inversion and geological interpretation. This study aims to determine the minimum value of signal-to-noise ratio (SNR) which maintains the effectiveness of remote reference technique. Results of standard time series simulation, addition of different Gaussian noises to obtain the different SNR time series, and analysis of the intermediate data, such as polarization direction, correlation coefficient, and impedance tensor, show that when the SNR value is larger than 23.5743, the polarization direction disorder at morphology and a smooth and accurate sounding carve value can be obtained. At this condition, the correlation coefficient value of nearly complete segments between the base and remote station is larger than 0.9, and impedance tensor Zxy presents only one aggregation, which meet the natural magnetotelluric signal characteristic.
Tolosa, Imma; Cassi, Roberto; Huertas, David
2018-04-11
A new marine sediment certified reference material (IAEA 459) with very low concentrations (μg kg -1 ) for a variety of persistent organic contaminants (POPs) listed by the Stockholm Convention, as well as other POPs and priority substances (PSs) listed in many environmental monitoring programs was developed by the IAEA. The sediment material was collected from the Ham River estuary in South Korea, and the assigned final values were derived from robust statistics on the results provided by selected laboratories which demonstrated technical and quality competence, following the guidance given in ISO Guide 35. The robust mean of the laboratory means was assigned as certified values, for those compounds where the assigned value was derived from at least five datasets and its relative expanded uncertainty was less than 40% of the assigned value (most of the values ranging from 8 to 20%). All the datasets were derived from at least two different analytical techniques which have allowed the assignment of certified concentrations for 22 polychlorinated biphenyl (PCB) congeners, 6 organochlorinated (OC) pesticides, 5 polybrominated diphenyl ethers (PBDEs), and 18 polycyclic aromatic hydrocarbon (PAHs). Mass fractions of compounds that did not fulfill the criteria of certification are considered information values, which include 29 PAHs, 11 PCBs, 16 OC pesticides, and 5 PBDEs. The extensive characterization and associated uncertainties at concentration levels close to the marine sediment quality guidelines will make CRM 459 a valuable matrix reference material for use in marine environmental monitoring programs.
Establishing reference intervals for electrolytes in newborns and infants using direct ISE analyzer
2013-01-01
Background To generate clinically applicable reference intervals (RIs) for commonly requested electrolytes in Ethiopian newborns and infants that can help in early detection, close monitoring and correction of electrolyte abnormalities. Cord blood (from newborns, n = 60) and venous blood samples (from infants, n = 57) were collected and analyzed using direct ISE analyzer, AVL (9181). MedCalc® software was applied to determine the robust upper and lower end points covering 95% of the reference values of each electrolyte with respective 90% CIs. Findings This is an extension report of our recent study; and hence is resulted from the same data source. The level of Na+ and K+ showed difference in newborns and infants even though combined RIs were suggested by the Haris and Boyd rule as 126–143 mmol/l and 4.0-7.9 mmol/l respectively. However, Cl- values failed to show such a difference and thus a combined RI was determined to be 100–111 mmol/l. Almost all maternal, neonatal and infantile factors were not able to affect the values of the electrolytes. Conclusion Combined RIs are suggested for the interpretation of electrolyte values in newborns and infants without taking the effect of maternal, neonatal and infantile factors into account. Since the RIs were different from previously reported values, it will be appropriate to apply such RIs for the interpretation of electrolyte values in Ethiopian pediatric population. PMID:23688032
Abe, Yuki; Shibata, Yoko; Igarashi, Akira; Inoue, Sumito; Sato, Kento; Sato, Masamichi; Nemoto, Takako; Kobayashi, Maki; Nishiwaki, Michiko; Kimura, Tomomi; Tokairin, Yoshikane; Kayama, Takamasa; Kubota, Isao
2016-05-01
The forced oscillation technique (FOT) can measure respiratory system resistance and reactance under tidal volume respiration. MostGraph is a device that incorporates the FOT and enables the immediate, three-dimensional visualization of resistance and reactance parameters. The aim of this study was to establish MostGraph reference values for middle-aged and elderly Japanese individuals. From 2004 to 2006, 3253 subjects living in Takahata, Yamagata underwent spirometry. Of these, 872 again underwent spirometry in 2011, and 784 (368 men, ages 46-89 years; 416 women, ages 47-90 years) underwent FOT examinations using MostGraph-01. In this study population, 19.0% of the men and 91.5% of the women were life-long never smokers. Abnormal spirometric findings were observed in 30.2% of the men and 14.6% of the women. Although the respiratory system resistance and reactance parameters obtained using MostGraph were not distributed normally, normal distribution was achieved via natural logarithm (R5, R20, Fres, and ALX), square root (R5-R20), or exponential (X5) transformation. Furthermore, the transformed values were converted back to the actual values after determining the values representing one and two standard deviations from the mean. Respiratory system resistance and reactance reference values were determined using MostGraph in middle-aged and elderly Japanese individuals who participated in annual health checkups. Copyright © 2016 The Japanese Respiratory Society. Published by Elsevier B.V. All rights reserved.
Review of utility values for economic modeling in type 2 diabetes.
Beaudet, Amélie; Clegg, John; Thuresson, Per-Olof; Lloyd, Adam; McEwan, Phil
2014-06-01
Economic analysis in type 2 diabetes mellitus (T2DM) requires an assessment of the effect of a wide range of complications. The objective of this article was to identify a set of utility values consistent with the National Institute for Health and Care Excellence (NICE) reference case and to critically discuss and illustrate challenges in creating such a utility set. A systematic literature review was conducted to identify studies reporting utility values for relevant complications. The methodology of each study was assessed for consistency with the NICE reference case. A suggested set of utility values applicable to modeling was derived, giving preference to studies reporting multiple complications and correcting for comorbidity. The review considered 21 relevant diabetes complications. A total of 16,574 articles were identified; after screening, 61 articles were assessed for methodological quality. Nineteen articles met NICE criteria, reporting utility values for 20 of 21 relevant complications. For renal transplant, because no articles meeting NICE criteria were identified, two articles using other methodologies were included. Index value estimates for T2DM without complication ranged from 0.711 to 0.940. Utility decrement associated with complications ranged from 0.014 (minor hypoglycemia) to 0.28 (amputation). Limitations associated with the selection of a utility value for use in economic modeling included variability in patient recruitment, heterogeneity in statistical analysis, large variability around some point estimates, and lack of recent data. A reference set of utility values for T2DM and its complications in line with NICE requirements was identified. This research illustrates the challenges associated with systematically selecting utility data for economic evaluations. Copyright © 2014 International Society for Pharmacoeconomics and Outcomes Research (ISPOR). Published by Elsevier Inc. All rights reserved.
Frankenstein, Lutz; Zugck, Christian; Nelles, Manfred; Schellberg, Dieter; Katus, Hugo; Remppis, Andrew
2008-04-01
The 6-minute walk test (6MWT) is an established prognostic tool in chronic heart failure. The strong influence of height, weight, age, and sex on 6MWT distance may be accounted for by using percentage achieved of predicted value rather than uncorrected 6MWT values. The study included 1069 patients (862 men) with a mean age 55.2 +/- 11.7 years and mean left ventricular ejection fraction of 29% +/- 10%, attending the heart failure clinic of the University of Heidelberg between 1995 and 2005. The predictive power and accuracy of 6MWT and achieved percentage values according to all available published equations for mortality and mortality or transplant combined were tested separately for each sex. The percentage values varied largely between equations. For all equations, women in New York Heart Association (NYHA) functional class I had higher values than men. Although the 6MWT significantly discriminated all NYHA classes for both sexes, only 1 equation discriminated all NYHA classes. No significant differences in the area under the receiver operating-characteristic curve were noted between achieved percentage values and 6MWT. Despite strong univariate significance, achieved percentage values did not retain multivariate significance. The 6MWT was independent from N-terminal brain natriuretic propeptide, NYHA, left ventricular ejection fraction, and peak oxygen uptake. We confirmed 6MWT to be a strong and independent risk predictor for both sexes. Because the prognostic power of 6MWT is not enhanced using percentage achieved of published reference equations, we suggest recalibration of these reference values rather than discarding this approach.
Erhardt, E; Foraita, R; Pigeot, I; Barba, G; Veidebaum, T; Tornaritis, M; Michels, N; Eiben, G; Ahrens, W; Moreno, L A; Kovács, E; Molnár, D
2014-09-01
To establish age- and sex-specific reference values for serum leptin and adiponectin in normal-weight 3.0-8.9-year old European children. Blood samples for hormone analysis were taken from 1338 children of the IDEFICS (Identification and prevention of Dietary- and lifestyle-induced health Effects in Children and infantS) study cohort. Only normal-weight children aged 3.0-8.9 years were included (n=539) in our analysis. Using the General Additive Model for Location Scale and Shape, age- and sex-specific percentiles were derived. The influence of under/overweight and obesity on the proposed reference curves based on normal-weight children was investigated in several sensitivity analyses using the sample without obese children (n=1015) and the whole study sample (n=1338). There was a negative age trend of adiponectin blood levels and a positive trend of leptin levels in boys and girls. Percentiles derived for girls were generally higher than those obtained for boys. The corresponding age-specific differences of the 97th percentile ranged from -2.2 to 4.6 μg ml(-1) and from 2.2 to 4.8 ng ml(-1) for adiponectin and leptin, respectively. According to our knowledge, these are the first reference values of leptin and adiponectin in prepubertal, normal-weight children. The presented adiponectin and leptin reference curves may allow for a more differentiated interpretation of children's hormone levels in epidemiological and clinical studies.
Byrdwell, William Craig
2014-08-01
An "extract-filter-shoot" method for the analysis of vitamin D2, ergocalciferol, in a dry powdered dietary supplement capsule containing rice flour excipient and in a National Institute of Standards and Technology standard reference material 3280 is reported. Quantification of vitamin D2 was done by atmospheric pressure chemical ionization mass spectrometry using selected ion monitoring, two transitions of selected reaction monitoring, and extracted ion chromatograms from full scans. UV detection was used for the quantification of Vitamin D2 in the dry powder capsule, whereas interfering species rendered UV detection unreliable for standard reference material 3280. Average values for standard reference material 3280 ranged from 8.27 ± 0.58 to 8.33 ± 0.57 μg/g using internal standard calibration and response factor approaches, compared to the previous National Institute of Standards and Technology internal value for vitamin D2 of 8.78 ± 0.11 μg/g, and the recently updated reference value of 8.6 ± 2.6 μg/g. The powdered supplement capsule was found to contain 28.19 ± 0.35 to 28.67 ± 0.90 μg/capsule for a capsule labeled to contain 25.00 μg. The triacylglycerol composition of the rice flour excipient in the powdered supplement capsule determined by atmospheric pressure chemical ionization mass spectrometry is also reported. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Lack of harmonization in sweat testing for cystic fibrosis - a national survey.
Christiansen, Anne Lindegaard; Nybo, Mads
2014-11-01
Sweat testing is used in the diagnosis of cystic fibrosis. Interpretation of the sweat test depends, however, on the method performed since conductivity, osmolality and chloride concentration all can be measured as part of a sweat test. The aim of this study was to investigate how performance of the test is organized in Denmark. Departments conducting the sweat test were contacted and interviewed following a premade questionnaire. They were asked about methods performed, applied NPU (Nomenclature for Properties and Units) code, reference interval, recommended interpretation and referred literature. 14 departments performed the sweat test. One department measured chloride and sodium concentration, while 13 departments measured conductivity. One department used a non-existing NPU code, two departments applied NPU codes inconsistent with the method performed, four departments applied no NPU code and seven applied a correct NPU code. Ten of the departments measuring conductivity applied reference intervals. Nine departments measuring conductivity had recommendations of a normal area, a grey zone and a pathological value, while four departments only applied a normal and grey zone or a pathological value. Cut-off values for normal, grey and pathological areas were like the reference intervals inconsistent. There is inconsistent use of NPU codes, reference intervals and interpretation of sweat conductivity used in the process of diagnosing cystic fibrosis. Because diagnosing cystic fibrosis is a combined effort between local pediatric departments, biochemical and genetic departments and cystic fibrosis centers, a national harmonization is necessary to assure correct clinical use.
Determination of Perfluorinated Alkyl Acid Concentrations in Biological Standard Reference Materials
Standard reference materials (SRMs) are homogeneous, well-characterized materials used to validate measurements and improve the quality of analytical data. The National Institute of Standards and Technology (NIST) has a wide range of SRMs that have mass fraction values assigned ...
Reference Intervals of Hematology and Clinical Chemistry Analytes for 1-Year-Old Korean Children
Lee, Hye Ryun; Roh, Eun Youn; Chang, Ju Young
2016-01-01
Background Reference intervals need to be established according to age. We established reference intervals of hematology and chemistry from community-based healthy 1-yr-old children and analyzed their iron status according to the feeding methods during the first six months after birth. Methods A total of 887 children who received a medical check-up between 2010 and 2014 at Boramae Hospital (Seoul, Korea) were enrolled. A total of 534 children (247 boys and 287 girls) were enrolled as reference individuals after the exclusion of data obtained from children with suspected iron deficiency. Hematology and clinical chemistry analytes were measured, and the reference value of each analyte was estimated by using parametric (mean±2 SD) or nonparametric methods (2.5-97.5th percentile). Iron, total iron-binding capacity, and ferritin were measured, and transferrin saturation was calculated. Results As there were no differences in the mean values between boys and girls, we established the reference intervals for 1-yr-old children regardless of sex. The analysis of serum iron status according to feeding methods during the first six months revealed higher iron, ferritin, and transferrin saturation levels in children exclusively or mainly fed formula than in children exclusively or mainly fed breast milk. Conclusions We established reference intervals of hematology and clinical chemistry analytes from community-based healthy children at one year of age. These reference intervals will be useful for interpreting results of medical check-ups at one year of age. PMID:27374715
Reference Intervals of Hematology and Clinical Chemistry Analytes for 1-Year-Old Korean Children.
Lee, Hye Ryun; Shin, Sue; Yoon, Jong Hyun; Roh, Eun Youn; Chang, Ju Young
2016-09-01
Reference intervals need to be established according to age. We established reference intervals of hematology and chemistry from community-based healthy 1-yr-old children and analyzed their iron status according to the feeding methods during the first six months after birth. A total of 887 children who received a medical check-up between 2010 and 2014 at Boramae Hospital (Seoul, Korea) were enrolled. A total of 534 children (247 boys and 287 girls) were enrolled as reference individuals after the exclusion of data obtained from children with suspected iron deficiency. Hematology and clinical chemistry analytes were measured, and the reference value of each analyte was estimated by using parametric (mean±2 SD) or nonparametric methods (2.5-97.5th percentile). Iron, total iron-binding capacity, and ferritin were measured, and transferrin saturation was calculated. As there were no differences in the mean values between boys and girls, we established the reference intervals for 1-yr-old children regardless of sex. The analysis of serum iron status according to feeding methods during the first six months revealed higher iron, ferritin, and transferrin saturation levels in children exclusively or mainly fed formula than in children exclusively or mainly fed breast milk. We established reference intervals of hematology and clinical chemistry analytes from community-based healthy children at one year of age. These reference intervals will be useful for interpreting results of medical check-ups at one year of age.
Costa, Ana Maria Aranha Magalhaes; Magluta, Cynthia; Gomes Junior, Saint Clair
2017-09-07
This study evaluated the influence of continuing education of family health strategy teams by the Ronald McDonald Institute program on the early diagnosis of cancer in children and adolescents. The study applied Habicht's model to evaluate the adequacy and plausibility of continuing education by using as outcome the number of children with suspected cancer who were referred to the hospital of references in the 1 year before and 1 year after intervention and the number of patients referred by intervention group and control group family health strategy teams. Medical records from each hospital of reference were used to collect information of suspect cases of cancer. Descriptive analyses were performed using frequencies and mean values. Chi-square tests were used to assess statistically significant differences between the groups and periods by using p-values < 0.05. The results showed a 30.6% increase in the number of children referred to the hospital of reference for suspected cancer in the post-intervention period; in addition, the family health strategy teams that underwent the intervention referred 3.6 times more number of children to hospital of references than did the control group. Only the intervention group showed an increase in the number of confirmed cases. This evaluation of a continuing education program for early identification of pediatric cancer showed that the program was adequate in achieving the established goals and that the results could be attributed to the program.
Villalobos Reyes, Marjorie; Mederico, Maracelly; Paoli de Valeri, Mariela; Briceño, Yajaira; Zerpa, Yajaira; Gómez-Pérez, Roald; Camacho, Nolis; Martínez, José Luis; Valeri, Lenín; Arata-Bellabarba, Gabriela
2014-11-01
To obtain local reference values for blood lipids and blood pressure (BP), and to determine the prevalence of metabolic syndrome (MS) in children and adolescents from Mérida, Venezuela, and to compare results using local and international cut-off values. The study enrolled 916 participants of both sexes aged 9-18 years of age from educational institutions. Demographic, anthropometric, and BP data were collected. Fasting blood glucose and lipid profile were measured. Percentile distribution of lipid and BP values was done by age group and sex. Prevalence of MS was estimated based on the NCEP-ATPIII classification (as modified by Cook et al.) and the classification of the International Diabetes Federation, using percentiles of Mérida and the USA as cut-off points. Agreement between both classifications was estimated using the kappa test (κ). Prevalence of MS was 2.2% by Cook-Merida percentiles, as compared to 1.8% by Cook-USA percentiles, a moderate agreement (κ=0.54). Agreement between Cook et al. and IDF using Merida percentiles was weak (κ=0.28). There was a higher frequency of abdominal obesity, hypertriglyceridemia and hypertension, and a lower frequency of low HDL-C using Mérida percentiles. The risk (odds ratio) of having MS is greater if abdominal obesity exists (OR: 98.63, CI: 22.45-433.35, p=0.0001). MS was significantly more common in obese subjects (18.3%, p=0.0001). Prevalence of MS in this sample of children and adolescents was 2.2%. Lipid and BP values were lower in Venezuelan as compared to US, European, and Asian children and adolescents, and similar to those in Latin-American references. Own reference values are required for accurate diagnosis of MS, as well as a worldwide consensus on its diagnostic criteria. Copyright © 2014 SEEN. Published by Elsevier Espana. All rights reserved.
Zhang, Chuanbao; Guo, Wei; Huang, Hengjian; Ma, Yueyun; Zhuang, Junhua; Zhang, Jie
2013-01-01
Background Reference intervals of Liver function tests are very important for the screening, diagnosis, treatment, and monitoring of liver diseases. We aim to establish common reference intervals of liver function tests specifically for the Chinese adult population. Methods A total of 3210 individuals (20–79 years) were enrolled in six representative geographical regions in China. Analytes of ALT, AST, GGT, ALP, total protein, albumin and total bilirubin were measured using three analytical systems mainly used in China. The newly established reference intervals were based on the results of traceability or multiple systems, and then validated in 21 large hospitals located nationwide qualified by the National External Quality Assessment (EQA) of China. Results We had been established reference intervals of the seven liver function tests for the Chinese adult population and found there were apparent variances of reference values for the variables for partitioning analysis such as gender(ALT, GGT, total bilirubin), age(ALP, albumin) and region(total protein). More than 86% of the 21 laboratories passed the validation in all subgroup of reference intervals and overall about 95.3% to 98.8% of the 1220 validation results fell within the range of the new reference interval for all liver function tests. In comparison with the currently recommended reference intervals in China, the single side observed proportions of out of range of reference values from our study for most of the tests deviated significantly from the nominal 2.5% such as total bilirubin (15.2%), ALP (0.2%), albumin (0.0%). Most of reference intervals in our study were obviously different from that of other races. Conclusion These used reference intervals are no longer applicable for the current Chinese population. We have established common reference intervals of liver function tests that are defined specifically for Chinese population and can be universally used among EQA-approved laboratories located all over China. PMID:24058449
[Investigation of adolescents' bone metabolism in the western part of Transdanubia].
Csákváry, Violetta; Puskás, Tamás; Bödecs, Tamás; Lôcsei, Zoltán; Oroszlán, György; Kovács, L Gábor; Toldy, Erzsébet
2009-10-25
Childhood reference range based on the age is not available in Hungary, therefore the diagnosis and therapy of bone metabolic diseases of childhood are subject to difficulties. The aim of this work is to provide information about the adolescents' results of bone mineral density and bone biomarkers. Measurements were performed in 169 healthy adolescents (98 girls, 71 boys, age: 17.0+/-1.2 years). Bone mineral content (BMC) and bone mineral density (BMD) of the lumbar spine were measured using Double X-ray Absorptiometry (DXA, LUNAR, GE Health Care, USA) and Z-score values were analyzed using different reference population. In the serum, bone biomarkers osteocalcin (OC) and beta-crosslaps (beta-Cl) were measured by a fully automated, electrochemiluminescence immunoassay method (Elecsys-2010, Roche). Data were analyzed according to gender and the Tanner stage and grade system. Associations between body mass index (BMI), calcium intake, consumption of soft drinks and coke, and physical exercise were investigated. BMC values for both age groups were significantly elevated in boys of the Tanner stage V. (15-16 years: 62.9+/-14.3 g; 17-19 years: 69.8+/-9.3g) than in girls (58.1+/-10.4; 61.6+/-8.5 g) (p<0.001). BMD values were higher in girls, than in boys (1.17+/-0.12 g/cm 2 vs. 1.13+/-0.11 g/cm 2) (p<0.05). OC and beta-Cl levels showed negative correlation with age in both gender (p<0.01), while OC and beta-Cl levels were higher in boys, than in girls (p<0.001). Elevation of BMC and BMD values were associated with increase of BMI in both gender (p<0.05), but the biomarkers in thin girls were higher, than in overweight girls (p<0.05). Authors obtained excellent correlations between the BMD-Z-score values compared to the German standard and to their own population (girls: r=0.97, boys: 0.88), but the absolute values significantly differed from one another. 80% of adolescents are on a diet with insufficient calcium intake, while 38% of them do not play sport regularly. Excessive intake of soft drinks was determined in 60% of adolescents. In the case of insufficient calcium intake (4.7%, 6/127), low bone mass was measured using the Z-score of the German reference values. Among children with adequate calcium intake, BMD assessed by DXA was normal. These data help to determine normal reference values among healthy high school students. Further studies are needed in wider range of young population for the establishment of Hungarian reference values of bone markers.
Object Relations and the Development of Values.
ERIC Educational Resources Information Center
Gazda, George M.; Sedgwick, Charlalee
1990-01-01
Claims acquisition of values is related to successes and failures of early relationships. Describes steps person goes through in making identifications, explaining steps that move person toward construction of value system. Refers to works of Heinz Kohut to explain how child's idealizing has within it necessary components for child's growth in…
Forage accumulation and nutritive value of reduced lignin and reference alfalfa cultivars
USDA-ARS?s Scientific Manuscript database
Reduced lignin alfalfa (Medicago sativa L.) cultivars have the potential to increase the feeding value of alfalfa for livestock by improving the forage fiber digestibility and to increase harvest management flexibility. The objectives were to compare the yield and forage nutritive value of reduced ...
DOT National Transportation Integrated Search
2015-08-01
Depth-Duration-Frequency coefficients for Texas were updated from findings reported in Asquith (1998) and Asquith and Roussel (2004) and are herein referred to as the 2015DDF values. The 2015DDF values were used to estimate the 2015ebd value...
Values Education and Some Suggestions to Teachers
ERIC Educational Resources Information Center
Demirhan Iscan, Canay
2011-01-01
This paper focuses on the process, approaches and teacher roles in values education and offers recommendations for teachers. It uses print materials and Internet sources on values education. These sources were analyzed and synthesized to reveal certain cases and/or opinions. In addition to contemporary sources, older reference materials were also…
Teachers' Cultural Ideology: Patterns of Curriculum and Teaching Culturally Valued Texts
ERIC Educational Resources Information Center
Shkedi, Asher; Nisan, Mordecai
2006-01-01
This study sought to reveal teachers' personal cultural ideologies as reflected in their conceptions of the curriculum for, and in their actual teaching of, culturally valued texts. The concept "teachers' personal cultural ideologies" refers to their value orientation toward the curricular and teaching contents relating to, in this…
Exploring the Value Orientations of Inuit and White Students: An Empirical Inquiry.
ERIC Educational Resources Information Center
Roberts, Lance W.; And Others
1989-01-01
Finds that, among 46 Inuit and 11 White 10-16-year-old students in the Northwest Territories (Canada), Inuit students had less modern values than their white peers, but Inuit scores varied considerably both within and among the 5 value orientations examined. Contains 34 references. (SV)
Getting Value out of Value-Added: Report of a Workshop
ERIC Educational Resources Information Center
Braun, Henry, Ed.; Chudowsky, Naomi, Ed.; Koenig, Judith, Ed.
2010-01-01
Value-added methods refer to efforts to estimate the relative contributions of specific teachers, schools, or programs to student test performance. In recent years, these methods have attracted considerable attention because of their potential applicability for educational accountability, teacher pay-for-performance systems, school and teacher…
Threshold-driven optimization for reference-based auto-planning
NASA Astrophysics Data System (ADS)
Long, Troy; Chen, Mingli; Jiang, Steve; Lu, Weiguo
2018-02-01
We study threshold-driven optimization methodology for automatically generating a treatment plan that is motivated by a reference DVH for IMRT treatment planning. We present a framework for threshold-driven optimization for reference-based auto-planning (TORA). Commonly used voxel-based quadratic penalties have two components for penalizing under- and over-dosing of voxels: a reference dose threshold and associated penalty weight. Conventional manual- and auto-planning using such a function involves iteratively updating the preference weights while keeping the thresholds constant, an unintuitive and often inconsistent method for planning toward some reference DVH. However, driving a dose distribution by threshold values instead of preference weights can achieve similar plans with less computational effort. The proposed methodology spatially assigns reference DVH information to threshold values, and iteratively improves the quality of that assignment. The methodology effectively handles both sub-optimal and infeasible DVHs. TORA was applied to a prostate case and a liver case as a proof-of-concept. Reference DVHs were generated using a conventional voxel-based objective, then altered to be either infeasible or easy-to-achieve. TORA was able to closely recreate reference DVHs in 5-15 iterations of solving a simple convex sub-problem. TORA has the potential to be effective for auto-planning based on reference DVHs. As dose prediction and knowledge-based planning becomes more prevalent in the clinical setting, incorporating such data into the treatment planning model in a clear, efficient way will be crucial for automated planning. A threshold-focused objective tuning should be explored over conventional methods of updating preference weights for DVH-guided treatment planning.
Optimal Reference Gene Selection for Expression Studies in Human Reticulocytes.
Aggarwal, Anu; Jamwal, Manu; Viswanathan, Ganesh K; Sharma, Prashant; Sachdeva, ManUpdesh S; Bansal, Deepak; Malhotra, Pankaj; Das, Reena
2018-05-01
Reference genes are indispensable for normalizing mRNA levels across samples in real-time quantitative PCR. Their expression levels vary under different experimental conditions and because of several inherent characteristics. Appropriate reference gene selection is thus critical for gene-expression studies. This study aimed at selecting optimal reference genes for gene-expression analysis of reticulocytes and at validating them in hereditary spherocytosis (HS) and β-thalassemia intermedia (βTI) patients. Seven reference genes (PGK1, MPP1, HPRT1, ACTB, GAPDH, RN18S1, and SDHA) were selected because of published reports. Real-time quantitative PCR was performed on reticulocytes in 20 healthy volunteers, 15 HS patients, and 10 βTI patients. Threshold cycle values were compared with fold-change method and RefFinder software. The stable reference genes recommended by RefFinder were validated with SLC4A1 and flow cytometric eosin-5'-maleimide binding assay values in HS patients and HBG2 and high performance liquid chromatography-derived percentage of hemoglobin F in βTI. Comprehensive ranking predicted MPP1 and GAPDH as optimal reference genes for reticulocytes that were not affected in HS and βTI. This was further confirmed on validation with eosin-5'-maleimide results and percentage of hemoglobin F in HS and βTI patients, respectively. Hence, MPP1 and GAPDH are good reference genes for reticulocyte expression studies compared with ACTB and RN18S1, the two most commonly used reference genes. Copyright © 2018 American Society for Investigative Pathology and the Association for Molecular Pathology. Published by Elsevier Inc. All rights reserved.
Yang, Qian; Lew, Hwee Yeong; Peh, Raymond Hock Huat; Metz, Michael Patrick; Loh, Tze Ping
2016-10-01
Reference intervals are the most commonly used decision support tool when interpreting quantitative laboratory results. They may require partitioning to better describe subpopulations that display significantly different reference values. Partitioning by age is particularly important for the paediatric population since there are marked physiological changes associated with growth and maturation. However, most partitioning methods are either technically complex or require prior knowledge of the underlying physiology/biological variation of the population. There is growing interest in the use of continuous centile curves, which provides seamless laboratory reference values as a child grows, as an alternative to rigidly described fixed reference intervals. However, the mathematical functions that describe these curves can be complex and may not be easily implemented in laboratory information systems. Hence, the use of fixed reference intervals is expected to continue for a foreseeable time. We developed a method that objectively proposes optimised age partitions and reference intervals for quantitative laboratory data (http://research.sph.nus.edu.sg/pp/ppResult.aspx), based on the sum of gradient that best describes the underlying distribution of the continuous centile curves. It is hoped that this method may improve the selection of age intervals for partitioning, which is receiving increasing attention in paediatric laboratory medicine. Copyright © 2016 Royal College of Pathologists of Australasia. Published by Elsevier B.V. All rights reserved.
Soy foods have low glycemic and insulin response indices in normal weight subjects.
Blair, Robert M; Henley, E C; Tabor, Aaron
2006-12-27
Foods with a low glycemic index (GI) may provide a variety of health benefits. The objective of the present study was to measure the GI and insulin index (II) of select soy foods. The study was conducted in two parts with low-carbohydrate products being tested separately. In Experiment 1, subjects averaged 23.2 years of age with BMI = 22.0 kg/m2, while subjects in Experiment 2 averaged 23.9 years of age with BMI = 21.6 kg/m2. The reference (glucose) and test foods were served in portions containing 10 g of carbohydrates in Experiment 1 (two test foods) and 25 g of carbohydrates in Experiment 2 (four test foods). Subjects consumed the reference food twice and each test food once. For each test, subjects were instructed to consume a fixed portion of the reference food or test food together with 250 g of water within 12 min. Blood samples were collected before each test and at 15, 30, 45, 60, 90, and 120 min after consumption of reference or test foods to quantify glucose and insulin. Two-hour blood glucose and plasma insulin curves were constructed and areas under the curves were calculated. GI and II values for each subject and test food were calculated. In Experiment 1, both low-carbohydrate soy foods were shown to have significantly (P < 0.05) lower GI and II values than the reference food. In Experiment 2, three of the four test foods had significantly (P < 0.05) lower GI and II values than the reference food. All but one of the soy foods tested had a low GI, suggesting that soy foods may be an appropriate part of diets intended to improve control of blood glucose and insulin levels.
Soy foods have low glycemic and insulin response indices in normal weight subjects
2006-01-01
Background Foods with a low glycemic index (GI) may provide a variety of health benefits. The objective of the present study was to measure the GI and insulin index (II) of select soy foods. Methods The study was conducted in two parts with low-carbohydrate products being tested separately. In Experiment 1, subjects averaged 23.2 years of age with BMI = 22.0 kg/m2, while subjects in Experiment 2 averaged 23.9 years of age with BMI = 21.6 kg/m2. The reference (glucose) and test foods were served in portions containing 10 g of carbohydrates in Experiment 1 (two test foods) and 25 g of carbohydrates in Experiment 2 (four test foods). Subjects consumed the reference food twice and each test food once. For each test, subjects were instructed to consume a fixed portion of the reference food or test food together with 250 g of water within 12 min. Blood samples were collected before each test and at 15, 30, 45, 60, 90, and 120 min after consumption of reference or test foods to quantify glucose and insulin. Two-hour blood glucose and plasma insulin curves were constructed and areas under the curves were calculated. GI and II values for each subject and test food were calculated. Results In Experiment 1, both low-carbohydrate soy foods were shown to have significantly (P < 0.05) lower GI and II values than the reference food. In Experiment 2, three of the four test foods had significantly (P < 0.05) lower GI and II values than the reference food. Conclusion All but one of the soy foods tested had a low GI, suggesting that soy foods may be an appropriate part of diets intended to improve control of blood glucose and insulin levels. PMID:17192192
Comparative study of methodologies for pulse wave velocity estimation.
Salvi, P; Magnani, E; Valbusa, F; Agnoletti, D; Alecu, C; Joly, L; Benetos, A
2008-10-01
Arterial stiffness, estimated by pulse wave velocity (PWV), is an independent predictor of cardiovascular mortality and morbidity. However, the clinical applicability of these measurements and the elaboration of reference PWV values are difficult due to differences between the various devices used. In a population of 50 subjects aged 20-84 years, we compared PWV measurements with three frequently used devices: the Complior and the PulsePen, both of which determine aortic PWV as the delay between carotid and femoral pressure wave and the PulseTrace, which estimates the Stiffness Index (SI) by analyzing photoplethysmographic waves acquired on the fingertip. PWV was measured twice by each device. Coefficient of variation of PWV was 12.3, 12.4 and 14.5% for PulsePen, Complior and PulseTrace, respectively. These measurements were compared with the reference method, that is, a simultaneous acquisition of pressure waves using two tonometers. High correlation coefficients with the reference method were observed for PulsePen (r = 0.99) and Complior (r = 0.83), whereas for PulseTrace correlation with the reference method was much lower (r = 0.55). Upon Bland-Altman analysis, mean differences of values +/- 2s.d. versus the reference method were -0.15 +/- 0.62 m/s, 2.09 +/- 2.68 m/s and -1.12 +/- 4.92 m/s, for PulsePen, Complior and Pulse-Trace, respectively. This study confirms the reliability of Complior and PulsePen devices in estimating PWV, while the SI determined by the PulseTrace device was found to be inappropriate as a surrogate of PWV. The present results indicate the urgent need for evaluation and comparison of the different devices to standardize PWV measurements and establish reference values.
Marrodán Serrano, María Dolores; González-Montero de Espinosa, Marisa; Herráez, Ángel; Alfaro, Emma Laura; Felipe Bejarano, Ignacio; Carmenate, María Margarita; Prado, Consuelo; Beatriz Lomaglio, Delia; López-Ejeda, Noemí; Martínez, Antonio; Mesa, María Soledad; Méndez Pérez, Betty; Meléndez, Juana María; Moreno Romero, Susana; Pacheco, Jose Luis; Vázquez, Vanessa; Dipierri, José E
2015-12-01
the assessment of the skinfold thickness is an objective measure of adiposity. Therefore, it is a useful tool for nutritional diagnosis and prevention of metabolic risk associated with excess fat in chilhood and adolescence. to provide percentiles of subscapular and triceps skinfolds for Hispanic American schoolchildren and compare them with those published by the Centers for Disease Control and Prevention (CDC) from United States, that it have been commonly used as a reference in most of these countries. subscapular and triceps skinfolds were measured in 9.973 schoolchildren 4-19 aged from Spain, Argentina, Cuba, Venezuela and Mexico with Holtain caliper with 0.2 mm accuracy. Percentiles were obtained with the LMS statistical method and were presented in tables divided in stages of 6 months and in curves graphics. The difference between Hispanic American and CDC mean values were provided for P3, P50 and P97 in mm and also were graphically represented. skinfolds measurements obviously increased with age in both sexes but, in boys, this increase is much more marked in highest percentiles between 8 and 13 years; this maximum is reached earlier than what occurs in CDC reference. In both sexes, all percentiles analized in Hispanic American schoolchildren were higher than the CDC reference except P97 up to 10 or 13 years that was notably smaller. the skinfolds percentiles of Hispanic American children and adolescents differ from CDC that are usually used as reference. The values of subscapular and triceps skinfolds provided in this study, could be applied to populations of a similar ethnic background, especially in comparative studies of body composition. Copyright AULA MEDICA EDICIONES 2014. Published by AULA MEDICA. All rights reserved.
Collinson, Paul O; Heung, Yen Ming; Gaze, David; Boa, Frances; Senior, Roxy; Christenson, Robert; Apple, Fred S
2012-01-01
We sought to determine the effect of patient selection on the 99th reference percentile of 2 sensitive and 1 high-sensitivity (hs) cardiac troponin assays in a well-defined reference population. Individuals>45 years old were randomly selected from 7 representative local community practices. Detailed information regarding the participants was collected via questionnaires. The healthy reference population was defined as individuals who had no history of vascular disease, hypertension, or heavy alcohol intake; were not receiving cardiac medication; and had blood pressure<140/90 mmHg, fasting blood glucose<110 mg/dL (approximately 6 mmol/L), estimated creatinine clearance>60 mL·min(-1)·(1.73 m2)(-1), and normal cardiac function according to results of echocardiography. Samples were stored at -70 °C until analysis for cardiac troponin I (cTnI) and cardiac troponin T (cTnT) and N-terminal pro-B-type natriuretic peptide. Application of progressively more stringent population selection strategies to the initial baseline population of 545 participants until the only individuals who remained were completely healthy according to the study criteria reduced the number of outliers seen and led to a progressive decrease in the 99th-percentile value obtained for the Roche hs-cTnT assay and the sensitive Beckman cTnI assay but not for the sensitive Siemens Ultra cTnI assay. Furthermore, a sex difference found in the baseline population for the hs-cTnT (P=0.0018) and Beckman cTnI assays (P<0.0001) progressively decreased with more stringent population selection criteria. The reference population selection strategy significantly influenced the 99th percentile reference values determined for troponin assays and the observed sex differences in troponin concentrations.
Oxygen saturation profile in healthy preterm infants.
Harigopal, S; Satish, H P; Taktak, A F G; Southern, K W; Shaw, N J
2011-09-01
To establish a reference range for oxygen saturation (SpO(2)) in well preterm infants to guide home oxygen therapy using a pulse oximeter and Pulse Oximetry Data Analysis Software (PODS). SpO(2) and heart-rate profiles of healthy preterm infants receiving mechanical ventilation for less than 6 h and supplemental oxygen for less than 48 h were monitored using a pulse oximeter. The stored data were downloaded from the monitor to a personal computer as individual files. Each infant's files of SpO(2) were subsequently displayed in graphic form, and a reference range was constructed using dedicated software, PODS. 43 infants were studied. The median value of all infants mean SpO(2) values was 95% (range 92-99%). The median duration of saturations less than 85% and between 85% and 90 % were 1% and 2% respectively. Using the study group median, 5th and 95th percentiles, a cumulative frequency curve of time against SpO(2) value was constructed (representing the reference range of SpO(2) profiles in healthy preterm infants). The SpO(2) reference range can be used as an easy and practical guide to compare SpO(2) profiles of infants on home oxygen therapy and guide their oxygen therapy.
CHNO Energetic Polymer Specific Heat Prediction From The Proposed Nominal/Generic (N/G) CP Concept
2007-02-01
HMX can exist in different solid polymorphic forms. At a certain temperature, TT, one form may change to another form if the heat energy of...more than 100 °K for TNT, HNS and HMX and over 200 °K for TETRYL, PETN, and RDX ). So based on the above remarks and similar remarks in References...are very close to (or equal to) the RDX CP values and TNT CP values near absolute zero. In Reference 7, two examples (TNT and HMX ) were selected for
Antigenic value of lyophilized phenolized antirabies vaccine.
VEERARAGHAVAN, N; SUBRAHMANYAN, T P
1961-01-01
The authors present the results of experiments, carried out at the Pasteur Institute of Southern India, Coonoor, in which various preparations of lyophilized and liquid phenolized antirabies vaccines were assessed for antigenicity in relation to the NIH (United States National Institutes of Health) Reference Vaccine 164 (the proposed International Reference Preparation of Rabies Vaccine). The claim that phenolized antirabies vaccines can be lyophilized without loss of antigenicity was fully substantiated: the lyophilized vaccines were found to possess high antigenic values and to retain their antigenicity better than the liquid vaccines during storage under the same conditions.
Strategies to Improve the Accuracy of Mars-GRAM Sensitivity Studies at Large Optical Depths
NASA Technical Reports Server (NTRS)
Justh, Hilary L.; Justus, Carl G.; Badger, Andrew M.
2010-01-01
The poster provides an overview of techniques to improve the Mars Global Reference Atmospheric Model (Mars-GRAM) sensitivity. It has been discovered during the Mars Science Laboratory (MSL) site selection process that the Mars Global Reference Atmospheric Model (Mars-GRAM) when used for sensitivity studies for TES MapYear = 0 and large optical depth values such as tau = 3 is less than realistic. A preliminary fix has been made to Mars-GRAM by adding a density factor value that was determined for tau = 0.3, 1 and 3.
Non-Invasive Method of Determining Absolute Intracranial Pressure
NASA Technical Reports Server (NTRS)
Yost, William T. (Inventor); Cantrell, John H., Jr. (Inventor); Hargens, Alan E. (Inventor)
2004-01-01
A method is presented for determining absolute intracranial pressure (ICP) in a patient. Skull expansion is monitored while changes in ICP are induced. The patient's blood pressure is measured when skull expansion is approximately zero. The measured blood pressure is indicative of a reference ICP value. Subsequently, the method causes a known change in ICP and measured the change in skull expansion associated therewith. The absolute ICP is a function of the reference ICP value, the known change in ICP and its associated change in skull expansion; and a measured change in skull expansion.
Zheng, Gaoxing; Qi, Xiaoying; Li, Yuzhu; Zhang, Wei; Yu, Yuguo
2018-01-01
The choice of different reference electrodes plays an important role in deciphering the functional meaning of electroencephalography (EEG) signals. In recent years, the infinity zero reference using the reference electrode standard technique (REST) has been increasingly applied, while the average reference (AR) was generally advocated as the best available reference option in previous classical EEG studies. Here, we designed EEG experiments and performed a direct comparison between the influences of REST and AR on EEG-revealed brain activity features for three typical brain behavior states (eyes-closed, eyes-open and music-listening). The analysis results revealed the following observations: (1) there is no significant difference in the alpha-wave-blocking effect during the eyes-open state compared with the eyes-closed state for both REST and AR references; (2) there was clear frontal EEG asymmetry during the resting state, and the degree of lateralization under REST was higher than that under AR; (3) the global brain functional connectivity density (FCD) and local FCD have higher values for REST than for AR under different behavior states; and (4) the value of the small-world network characteristic in the eyes-closed state is significantly (in full, alpha, beta and gamma frequency bands) higher than that in the eyes-open state, and the small-world effect under the REST reference is higher than that under AR. In addition, the music-listening state has a higher small-world network effect than the eyes-closed state. The above results suggest that typical EEG features might be more clearly presented by applying the REST reference than by applying AR when using a 64-channel recording. PMID:29593490
Lee, Kyoung Ho; Hahn, Seokyung; Lee, Kyung Won; Lee, Hak Jong; Kim, Tae Jung; Kang, Sung-Bum; Shin, Joong Ho; Park, Byung Joo
2006-01-01
Objective To assess the added value of coronal reformation for radiologists and for referring physicians or surgeons in the CT diagnosis of acute appendicitis. Materials and Methods Contrast-enhanced CT was performed using 16-detector-row scanners in 110 patients, 46 of whom had appendicitis. Transverse (5-mm thickness, 4-mm increment), coronal (5-mm thickness, 4-mm increment), and combined transverse and coronal sections were interpreted by four radiologists, two surgeons and two emergency physicians. The area under the receiver operating characteristic curve (Az value), sensitivity, specificity (McNemar test), diagnostic confidence and appendiceal visualization (Wilcoxon signed rank test) were compared. Results For radiologists, the additional coronal sections tended to increase the Az value (0.972 vs. 0.986, p = 0.076) and pooled sensitivity (92% [95% CI: 88, 96] vs. 96% [93, 99]), and enhanced appendiceal visualization in true-positive cases (p = 0.031). For non-radiologists, no such enhancement was observed, and the confidence for excluding acute appendicitis declined (p = 0.013). Coronal sections alone were inferior to transverse sections for diagnostic confidence as well as appendiceal visualization for each reader group studied (p < 0.05). Conclusion The added value of coronal reformation is more apparent for radiologists compared to referring physicians or surgeons in the CT diagnosis of acute appendicitis. PMID:16799269