Sample records for reflectometer key issues

  1. Analysis of the ITER low field side reflectometer transmission line system.

    PubMed

    Hanson, G R; Wilgen, J B; Bigelow, T S; Diem, S J; Biewer, T M

    2010-10-01

    A critical issue in the design of the ITER low field side reflectometer is the transmission line (TL) system. A TL connects each launcher to a diagnostic instrument. Each TL will typically consist of ∼42 m of corrugated waveguide and up to ten miter bends. Important issues for the performance of the TL system are mode conversion and reflections. Minimizing these issues are critical to minimizing standing waves and phase errors. The performance of TL system is analyzed and recommendations are given.

  2. 78 FR 46932 - Notice of Availability of Government-Owned Inventions; Available for Licensing

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-08-02

    ... APPARATUS, Issued on June 18, 2013//U.S. Patent Number 8,477,308: POLARIZED, SPECULAR REFLECTOMETER APPARATUS, Issued on July 2, 2013. ADDRESSES: Requests for copies of the inventions cited should be directed...

  3. Portable Infrared Reflectometer Designed and Manufactured for Evaluating Emittance in the Laboratory or in the Field

    NASA Technical Reports Server (NTRS)

    Jaworske, Donald A.

    2000-01-01

    The optical properties of materials play a key role in spacecraft thermal control. In space, radiant heat transfer is the only mode of heat transfer that can reject heat from a spacecraft. One of the key properties for defining radiant heat transfer is emittance, a measure of how efficiently a surface can reject heat in comparison to a perfect black body emitter. Heat rejection occurs in the infrared region of the spectrum, nominally in the range of 2 to 25 mm. To calculate emittance, one obtains the reflectance over this spectral range, calculates spectral absorptance by difference, and then uses Kirchhoff s Law and the Stefan-Boltzmann equation to calculate emittance. A new portable infrared reflectometer, the SOC 400t, was designed and manufactured to evaluate the emittance of surfaces and coatings in the laboratory or in the field. It was developed by Surface Optics Corporation under a contract with the NASA Glenn Research Center at Lewis Field to replace the Center s aging Gier-Dunkle DB-100 infrared reflectometer. The specifications for the new instrument include a wavelength range of 2 to 25 mm; reflectance repeatability of +/-1 percent; self-calibrating, near-normal spectral reflectance measurements; a full scan measurement time of 3.5 min, a sample size of 1.27 cm (0.5 in.); a spectral resolution selectable from 4, 8, 16, or 32/cm; and optical property characterization utilizing an automatic integration to calculate total emittance in a selectable temperature range.

  4. Reflectometer design using nonimaging optics

    NASA Astrophysics Data System (ADS)

    Snail, Keith A.

    1987-12-01

    A new type of two-stage reflectometer is proposed for the measurement of directional hemispherical reflectance. The proposed reflectometer consists of a primary collecting mirror coupled to a secondary mirror chosen to eliminate the Fresnel variation of the detector (or source) response. The secondary mirror shape needed is an inverted nonimaging compound parabolic concentrator (CPC). For direct mode operation, the detector is placed at the larger CPC aperture. Ray tracing of a CPC/ellipsoid reflectometer indicates that the throughput is high and isotropic. Design trade-offs and two-stage reflectometers employing a hemisphere and dual paraboloid primary are also discussed.

  5. Reflectometer design using nonimaging optics.

    PubMed

    Snail, K A

    1987-12-15

    A new type of two-stage reflectometer is proposed for the measurement of directional hemispherical reflectance. The proposed reflectometer consists of a primary collecting mirror coupled to a secondary mirror chosen to eliminate the Fresnel variation of the detector (or source) response. The secondary mirror shape needed is an inverted nonimaging compound parabolic concentrator (CPC). For direct mode operation, the detector is placed at the larger CPC aperture. Ray tracing of a CPC/ellipsoid reflectometer indicates that the throughput is high and isotropic. Design trade-offs and two-stage reflectometers employing a hemisphere and dual paraboloid primary are also discussed.

  6. First results of the SOL reflectometer on Alcator C-Mod.

    PubMed

    Lau, C; Hanson, G; Lin, Y; Wilgen, J; Wukitch, S; Labombard, B; Wallace, G

    2012-10-01

    A swept-frequency X-mode reflectometer has been built on Alcator C-Mod to measure the scrape-off layer (SOL) density profiles adjacent to the lower hybrid launcher. The reflectometer system operates between 100 and 146 GHz at sweep rates from 10 μs to 1 ms and covers a density range of ∼10(16)-10(20) m(-3) at B(0) = 5-5.4 T. This paper discusses the analysis of reflectometer density profiles and presents first experimental results of SOL density profile modifications due to the application of lower hybrid range-of-frequencies power to L-mode discharges. Comparison between density profiles measured by the X-mode reflectometer and scanning Langmuir probes is also shown.

  7. Portable six-port reflectometer for determining moisture content of biomass material

    USDA-ARS?s Scientific Manuscript database

    A portable six-port reflectometer (SPR) for determining moisture content of biomass material is proposed for the first time in this paper. The proposed system consists of a 5.13 GHz reflectometer used with an open-ended half-mode substrateintegrated waveguide (HMSIW) sensor. The complex permittivity...

  8. Advanced density profile reflectometry; the state-of-the-art and measurement prospects for ITER

    NASA Astrophysics Data System (ADS)

    Doyle, E. J.

    2006-10-01

    Dramatic progress in millimeter-wave technology has allowed the realization of a key goal for ITER diagnostics, the routine measurement of the plasma density profile from millimeter-wave radar (reflectometry) measurements. In reflectometry, the measured round-trip group delay of a probe beam reflected from a plasma cutoff is used to infer the density distribution in the plasma. Reflectometer systems implemented by UCLA on a number of devices employ frequency-modulated continuous-wave (FM-CW), ultrawide-bandwidth, high-resolution radar systems. One such system on DIII-D has routinely demonstrated measurements of the density profile over a range of electron density of 0-6.4x10^19,m-3, with ˜25 μs time and ˜4 mm radial resolution, meeting key ITER requirements. This progress in performance was made possible by multiple advances in the areas of millimeter-wave technology, novel measurement techniques, and improved understanding, including: (i) fast sweep, solid-state, wide bandwidth sources and power amplifiers, (ii) dual polarization measurements to expand the density range, (iii) adaptive radar-based data analysis with parallel processing on a Unix cluster, (iv) high memory depth data acquisition, and (v) advances in full wave code modeling. The benefits of advanced system performance will be illustrated using measurements from a wide range of phenomena, including ELM and fast-ion driven mode dynamics, L-H transition studies and plasma-wall interaction. The measurement capabilities demonstrated by these systems provide a design basis for the development of the main ITER profile reflectometer system. This talk will explore the extent to which these reflectometer system designs, results and experience can be translated to ITER, and will identify what new studies and experimental tests are essential.

  9. Characterization of the Multi-Blade 10B-based detector at the CRISP reflectometer at ISIS for neutron reflectometry at ESS

    NASA Astrophysics Data System (ADS)

    Piscitelli, F.; Mauri, G.; Messi, F.; Anastasopoulos, M.; Arnold, T.; Glavic, A.; Höglund, C.; Ilves, T.; Lopez Higuera, I.; Pazmandi, P.; Raspino, D.; Robinson, L.; Schmidt, S.; Svensson, P.; Varga, D.; Hall-Wilton, R.

    2018-05-01

    The Multi-Blade is a Boron-10-based gaseous thermal neutron detector developed to face the challenge arising in neutron reflectometry at neutron sources. Neutron reflectometers are challenging instruments in terms of instantaneous counting rate and spatial resolution. This detector has been designed according to the requirements given by the reflectometers at the European Spallation Source (ESS) in Sweden. The Multi-Blade has been installed and tested on the CRISP reflectometer at the ISIS neutron and muon source in U.K.. The results on the detailed detector characterization are discussed in this manuscript.

  10. Scrape-off layer reflectometer for Alcator C-Mod.

    PubMed

    Hanson, G R; Wilgen, J B; Lau, C; Lin, Y; Wallace, G M; Wukitch, S J

    2008-10-01

    A two-frequency x-mode reflectometer operating from 100 to 146 GHz is deployed on Alcator C-Mod to measure the density profile and fluctuations in the scrape-off layer (SOL) immediately in front of the new J-port ICRF antenna and the new C-port lower hybrid launcher. The reflectometer covers densities from 10(16) to 10(20) m(-3) at 5-5.4 T. To provide the greatest flexibility and capability to deal with density fluctuations approaching 100% peak-to-peak in the SOL, both full-phase and differential-phase measurement capabilities with sweep speeds of approximately 10 micros to >1 ms are implemented. The differential-phase measurement uses a difference frequency of 500 MHz, corresponding to cutoff layer separations ranging from about 0.1 to 1 mm. The reflectometer has six sets of launchers: three on the ICRF antenna and three on the lower hybrid launcher. Both the ICRF antenna and the lower hybrid launcher incorporate reflectometer antennas at their top, bottom, and midplane locations.

  11. NASA Hybrid Reflectometer Project

    NASA Technical Reports Server (NTRS)

    Lynch, Dana; Mancini, Ron (Technical Monitor)

    2002-01-01

    Time-domain and frequency-domain reflectometry have been used for about forty years to locate opens and shorts in cables. Interpretation of reflectometry data is as much art as science. Is there information in the data that is being missed? Can the reflectometers be improved to allow us to detect and locate defects in cables that are not outright shorts or opens? The Hybrid Reflectometer Project was begun this year at NASA Ames Research Center, initially to model wire physics, simulating time-domain reflectometry (TDR) signals in those models and validating the models against actual TDR data taken on testbed cables. Theoretical models of reflectometry in wires will give us an understanding of the merits and limits of these techniques and will guide the application of a proposed hybrid reflectometer with the aim of enhancing reflectometer sensitivity to the point that wire defects can be detected. We will point out efforts by some other researchers to apply wire physics models to the problem of defect detection in wires and we will describe our own initial efforts to create wire physics models and report on testbed validation of the TDR simulations.

  12. Experiment Automation with a Robot Arm using the Liquids Reflectometer Instrument at the Spallation Neutron Source

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zolnierczuk, Piotr A; Vacaliuc, Bogdan; Sundaram, Madhan

    The Liquids Reflectometer instrument installed at the Spallation Neutron Source (SNS) enables observations of chemical kinetics, solid-state reactions and phase-transitions of thin film materials at both solid and liquid surfaces. Effective measurement of these behaviors requires each sample to be calibrated dynamically using the neutron beam and the data acquisition system in a feedback loop. Since the SNS is an intense neutron source, the time needed to perform the measurement can be the same as the alignment process, leading to a labor-intensive operation that is exhausting to users. An update to the instrument control system, completed in March 2013, implementedmore » the key features of automated sample alignment and robot-driven sample management, allowing for unattended operation over extended periods, lasting as long as 20 hours. We present a case study of the effort, detailing the mechanical, electrical and software modifications that were made as well as the lessons learned during the integration, verification and testing process.« less

  13. Simultaneous measurements of X-ray reflectivity and grazing incidence fluorescence at BL-16 beamline of Indus-2

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Das, Gangadhar; Kane, S. R.; Khooha, Ajay

    2015-05-15

    A new multipurpose x-ray reflectometer station has been developed and augmented at the microfocus beamline (BL-16) of Indus-2 synchrotron radiation source to facilitate synchronous measurements of specular x-ray reflectivity and grazing incidence x-ray fluorescence emission from thin layered structures. The design and various salient features of the x-ray reflectometer are discussed. The performance of the reflectometer has been evaluated by analyzing several thin layered structures having different surface interface properties. The results reveal in-depth information for precise determination of surface and interface properties of thin layered materials demonstrating the immense potential of the combined measurements of x-ray reflectivity and grazingmore » incidence fluorescence on a single reflectometer.« less

  14. Methods to Determine the Deformation of the IRVE Hypersonic Inflatable Aerodynamic Decelerator

    NASA Technical Reports Server (NTRS)

    Young, William R.

    2011-01-01

    Small resonant targets used in conjunction with a microwave reflectometer to determine the deformation of the Hypersonic Inflatable Aerodynamic Decelerator (HIAD) during reentry are investigated. The reflectometer measures the distance to the targets and from this the HIAD deformation is determined. The HIAD is used by the Inflatable Reentry Vehicle Experiment (IRVE) which investigates the use of inflatable heat shields for atmospheric reentry. After several different microwave reflectometer systems were analyzed and compared it was determined that the most desirable for this application is the Frequency Doubling Target method.

  15. NIST High Accuracy Reference Reflectometer-Spectrophotometer

    PubMed Central

    Proctor, James E.; Yvonne Barnes, P.

    1996-01-01

    A new reflectometer-spectrophotometer has been designed and constructed using state-of-the-art technology to enhance optical properties of materials measurements over the ultraviolet, visible, and near-infrared (UV-Vis-NIR) wavelength range (200 nm to 2500 nm). The instrument, Spectral Tri-function Automated Reference Reflectometer (STARR), is capable of measuring specular and diffuse reflectance, bidirectional reflectance distribution function (BRDF) of diffuse samples, and both diffuse and non-diffuse transmittance. Samples up to 30 cm by 30 cm can be measured. The instrument and its characterization are described. PMID:27805081

  16. Application of Time Domain Reflectometers to Urban Settings

    EPA Science Inventory

    Time domain reflectometers (TDRs) are in-situ monitoring probes that produce a temperature-compensated signal proportional to soil moisture content of the surrounding material when calibrated to a particular media. Typically used in agricultural settings, TDRs may also be applied...

  17. Assessment of Clogging Dynamics in Permeable Pavement Systems with Time Domain Reflectometers

    EPA Science Inventory

    Infiltration is a primary functional mechanism in green infrastructure stormwater controls. This study used time domain reflectometers (TDRs) to measure spatial infiltration and assess clogging dynamics of permeable pavement systems in Edison, NJ, and Louisville, KY. In 2009, t...

  18. Techniques to Determine Maintenace Frequency of Permeable Pavement Systems with Time Domain Reflectometers (TDRs

    EPA Science Inventory

    As the surface clogs in permeable pavement systems, they lose effectiveness and require maintenance. There is limited direct guidance for determining when maintenance is needed to prevent surface runoff bypass. Research is being conducted using multiple time domain reflectomete...

  19. Application of Time Domain Reflectometers in Urban Settings

    EPA Science Inventory

    Time domain reflectometers (TDRs) are sensors that measure the volumetric water content of soils and porous media. The sensors consist of stainless steel rods connected to a circuit board in an epoxy housing. An electromagnetic pulse is propagated along the rods. The time, or per...

  20. Optimal design of reflectometer density profile measurements using a radar systems approach (invited) (abstract)

    NASA Astrophysics Data System (ADS)

    Doyle, E. J.; Kim, K. W.; Peebles, W. A.; Rhodes, T. L.

    1997-01-01

    Reflectometry is an attractive and versatile diagnostic technique that can address a wide range of measurement needs on fusion devices. However, progress in the area of profile measurement has been hampered by the lack of a well-understood basis for the optimum design and implementation of such systems. Such a design basis is provided by the realization that reflectometer systems utilized for density profile measurements are in fact specialized forms of radar systems. In this article five criteria are introduced by which reflectometer systems can be systematically designed for optimal performance: range resolution, spatial sampling, turbulence immunity, bandwidth optimization, and the need for adaptive data processing. Many of these criteria are familiar from radar systems analysis, and are applicable to reflectometry after allowance is made for differences stemming from the nature of the plasma target. These criteria are utilized to critically evaluate current reflectometer density profile techniques and indicate improvements that can impact current and next step devices, such as ITER.

  1. Development of frequency modulation reflectometer for KSTAR tokamak: Data analysis based on Gaussian derivative waveleta)

    NASA Astrophysics Data System (ADS)

    Seo, Seong-Heon; Lee, K. D.

    2012-10-01

    A frequency modulation reflectometer has been developed to measure the density profile of the KSTAR tokamak. It has two channels operating in X-mode in the frequency range of Q band (33-50 GHz) and V band (50-75 GHz). The full band is swept in 20 μs. The mixer output is directly digitized at the sampling rate of 100 MSamples/s. A new phase detection algorithm is developed to analyze both amplitude and frequency modulated signal. The algorithm is benchmarked for a synthesized amplitude modulation-frequency modulation signal. This new algorithm is applied to the data analysis of KSTAR reflectometer.

  2. Application of Time Domain Reflectometers in Urban Settings

    EPA Science Inventory

    This is a poster for the Million Trees NYC research symposium in New York City, NY, March 5-6, 2010. The poster gives a summary of how time domain reflectometers can be installed in urban fill soil, engineered bioretention media, and recycled concrete aggregate to document the ...

  3. Development of Surfaces Optically Suitable for Flat Solar Panels. [using a reflectometer which separately evaluates spectral and diffuse reflectivities of surfaces

    NASA Technical Reports Server (NTRS)

    1979-01-01

    A reflectometer which can separately evaluate the spectral and diffuse reflectivities of surfaces is described. A phase locked detection system for the reflectometer is also described. A selective coating on aluminum potentially useful for flat plate solar collector applications is presented. The coating is composed of strongly bound copper oxide (divalent) and is formed by an etching process performed on an aluminum alloy with high copper content. Fabrication costs are expected to be small due to the one stop fabrication process. A number of conclusions gathered from the literature as to the required optical properties of flat plate solar collectors are discussed.

  4. A novel technique for real-time estimation of edge pedestal density gradients via reflectometer time delay data

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zeng, L., E-mail: zeng@fusion.gat.com; Doyle, E. J.; Rhodes, T. L.

    2016-11-15

    A new model-based technique for fast estimation of the pedestal electron density gradient has been developed. The technique uses ordinary mode polarization profile reflectometer time delay data and does not require direct profile inversion. Because of its simple data processing, the technique can be readily implemented via a Field-Programmable Gate Array, so as to provide a real-time density gradient estimate, suitable for use in plasma control systems such as envisioned for ITER, and possibly for DIII-D and Experimental Advanced Superconducting Tokamak. The method is based on a simple edge plasma model with a linear pedestal density gradient and low scrape-off-layermore » density. By measuring reflectometer time delays for three adjacent frequencies, the pedestal density gradient can be estimated analytically via the new approach. Using existing DIII-D profile reflectometer data, the estimated density gradients obtained from the new technique are found to be in good agreement with the actual density gradients for a number of dynamic DIII-D plasma conditions.« less

  5. 2D microwave imaging reflectometer electronics.

    PubMed

    Spear, A G; Domier, C W; Hu, X; Muscatello, C M; Ren, X; Tobias, B J; Luhmann, N C

    2014-11-01

    A 2D microwave imaging reflectometer system has been developed to visualize electron density fluctuations on the DIII-D tokamak. Simultaneously illuminated at four probe frequencies, large aperture optics image reflections from four density-dependent cutoff surfaces in the plasma over an extended region of the DIII-D plasma. Localized density fluctuations in the vicinity of the plasma cutoff surfaces modulate the plasma reflections, yielding a 2D image of electron density fluctuations. Details are presented of the receiver down conversion electronics that generate the in-phase (I) and quadrature (Q) reflectometer signals from which 2D density fluctuation data are obtained. Also presented are details on the control system and backplane used to manage the electronics as well as an introduction to the computer based control program.

  6. Novel analysis technique for measuring edge density fluctuation profiles with reflectometry in the Large Helical Device.

    PubMed

    Creely, A J; Ida, K; Yoshinuma, M; Tokuzawa, T; Tsujimura, T; Akiyama, T; Sakamoto, R; Emoto, M; Tanaka, K; Michael, C A

    2017-07-01

    A new method for measuring density fluctuation profiles near the edge of plasmas in the Large Helical Device (LHD) has been developed utilizing reflectometry combined with pellet-induced fast density scans. Reflectometer cutoff location was calculated by proportionally scaling the cutoff location calculated with fast far infrared laser interferometer (FIR) density profiles to match the slower time resolution results of the ray-tracing code LHD-GAUSS. Plasma velocity profile peaks generated with this reflectometer mapping were checked against velocity measurements made with charge exchange spectroscopy (CXS) and were found to agree within experimental uncertainty once diagnostic differences were accounted for. Measured density fluctuation profiles were found to peak strongly near the edge of the plasma, as is the case in most tokamaks. These measurements can be used in the future to inform inversion methods of phase contrast imaging (PCI) measurements. This result was confirmed with both a fixed frequency reflectometer and calibrated data from a multi-frequency comb reflectometer, and this method was applied successfully to a series of discharges. The full width at half maximum of the turbulence layer near the edge of the plasma was found to be only 1.5-3 cm on a series of LHD discharges, less than 5% of the normalized minor radius.

  7. Measurement of ICRF wave propagation using a microwave reflectometer with fast antenna switching on GAMMA 10

    NASA Astrophysics Data System (ADS)

    Ikezoe, R.; Ichimura, M.; Itagaki, J.; Hirata, M.; Sumida, S.; Jang, S.; Izumi, K.; Tanaka, A.; Sekine, R.; Kubota, Y.; Shima, Y.; Kohagura, J.; Yoshikawa, M.; Sakamoto, M.; Nakashima, Y.

    2017-12-01

    Slow Alfvén wave in ion cyclotron range of frequency (ICRF) is a powerful tool to heat ions confined in a mirror field. In spite of its efficient heating effect that has been attained in the central cell of GAMMA 10, there are still unknown characteristics concerning boundary condition, transient variation of heating effect, exact picture of cyclotron damping, and so on. To study these characteristics in detail, a multi-point measurement of the waves inside the hot plasma has been recently developed by using a microwave reflectometer. In addition to a radial profile measurement that is available by a usual reflectometer, an axial measurement has been achieved by arraying transmitting and receiving horn antennas in the axial direction, which are repeatedly switched in time during a discharge with PIN diode switches. Another transmitting and receiving horn antenna pair was newly added to the system and probing at five cross sections was achieved in a single discharge with time resolution of about 1 ms at each antenna pair position. With the upgraded reflectometer system, axial and radial distributions of wave-induced fluctuations and those temporal behavior were clearly observed, offering valuable data on wave physics in a hot mirror plasma.

  8. Novel analysis technique for measuring edge density fluctuation profiles with reflectometry in the Large Helical Device

    NASA Astrophysics Data System (ADS)

    Creely, A. J.; Ida, K.; Yoshinuma, M.; Tokuzawa, T.; Tsujimura, T.; Akiyama, T.; Sakamoto, R.; Emoto, M.; Tanaka, K.; Michael, C. A.

    2017-07-01

    A new method for measuring density fluctuation profiles near the edge of plasmas in the Large Helical Device (LHD) has been developed utilizing reflectometry combined with pellet-induced fast density scans. Reflectometer cutoff location was calculated by proportionally scaling the cutoff location calculated with fast far infrared laser interferometer (FIR) density profiles to match the slower time resolution results of the ray-tracing code LHD-GAUSS. Plasma velocity profile peaks generated with this reflectometer mapping were checked against velocity measurements made with charge exchange spectroscopy (CXS) and were found to agree within experimental uncertainty once diagnostic differences were accounted for. Measured density fluctuation profiles were found to peak strongly near the edge of the plasma, as is the case in most tokamaks. These measurements can be used in the future to inform inversion methods of phase contrast imaging (PCI) measurements. This result was confirmed with both a fixed frequency reflectometer and calibrated data from a multi-frequency comb reflectometer, and this method was applied successfully to a series of discharges. The full width at half maximum of the turbulence layer near the edge of the plasma was found to be only 1.5-3 cm on a series of LHD discharges, less than 5% of the normalized minor radius.

  9. At-wavelength metrology facility for soft X-ray reflection optics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sokolov, A., E-mail: andrey.sokolov@helmholtz-berlin.de; Bischoff, P.; Eggenstein, F.

    2016-05-15

    A new Optics Beamline coupled to a versatile UHV reflectometer is successfully operating at BESSY-II. It is used to carry out at-wavelength characterization and calibration of in-house produced gratings and novel nano-optical devices as well as mirrors and multilayer systems in the UV and XUV spectral region. This paper presents most recent commissioning data of the beamline and shows their correlation with initial beamline design calculations. Special attention is paid to beamline key parameters which determine the quality of the measurements such as high-order suppression and stray light behavior. The facility is open to user operation.

  10. Coal-shale interface detection system

    NASA Technical Reports Server (NTRS)

    Campbell, R. A.; Hudgins, J. L.; Morris, P. W.; Reid, H., Jr.; Zimmerman, J. E. (Inventor)

    1979-01-01

    A coal-shale interface detection system for use with coal cutting equipment consists of a reciprocating hammer on which an accelerometer is mounted to measure the impact of the hammer as it penetrates the ceiling or floor surface of a mine. A pair of reflectometers simultaneously view the same surface. The outputs of the accelerometer and reflectometers are detected and jointly registered to determine when an interface between coal and shale is being cut through.

  11. Coal-shale interface detector

    NASA Technical Reports Server (NTRS)

    Reid, H., Jr. (Inventor)

    1980-01-01

    A coal-shale interface detector for use with coal cutting equipment is described. The detector consists of a reciprocating hammer with an accelerometer to measure the impact of the hammer as it penetrates the ceiling or floor surface of a mine. Additionally, a pair of reflectometers simultaneously view the same surface, and the outputs from the accelerometer and reflectometers are detected and jointly registered to determine when an interface between coal and shale is being cut through.

  12. Optimization studies of the ITER low field side reflectometer.

    PubMed

    Diem, S J; Wilgen, J B; Bigelow, T S; Hanson, G R; Harvey, R W; Smirnov, A P

    2010-10-01

    Microwave reflectometry will be used on ITER to measure the electron density profile, density fluctuations due to MHD/turbulence, edge localized mode (ELM) density transients, and as an L-H transition monitor. The ITER low field side reflectometer system will measure both core and edge quantities using multiple antenna arrays spanning frequency ranges of 15-155 GHz for the O-mode system and 55-220 GHz for the X-mode system. Optimization studies using the GENRAY ray-tracing code have been done for edge and core measurements. The reflectometer launchers will utilize the HE11 mode launched from circular corrugated waveguide. The launched beams are assumed to be Gaussian with a beam waist diameter of 0.643 times the waveguide diameter. Optimum launcher size and placement are investigated by computing the antenna coupling between launchers, assuming the launched and received beams have a Gaussian beam pattern.

  13. Study of coherent reflectometer for imaging internal structures of highly scattering media

    NASA Astrophysics Data System (ADS)

    Poupardin, Mathieu; Dolfi, Agnes

    1996-01-01

    Optical reflectometers are potentially useful tools for imaging internal structures of turbid media, particularly of biological media. To get a point by point image, an active imaging system has to distinguish light scattered from a sample volume and light scattered by other locations in the media. Operating this discrimination of light with reflectometers based on coherence can be realized in two ways: assuring a geometric selection or a temporal selection. In this paper we present both methods, showing in each case the influence of the different parameters on the size of the sample volume under the assumption of single scattering. We also study the influence on the detection efficiency of the coherence loss of the incident light resulting from multiple scattering. We adapt a model, first developed for atmospheric lidar in turbulent atmosphere, to get an analytical expression of this detection efficiency in the function of the optical coefficients of the media.

  14. Automated data acquisition and processing for a Hohlraum reflectometer

    NASA Technical Reports Server (NTRS)

    Difilippo, Frank; Mirtich, Michael J.

    1988-01-01

    A computer and data acquisition board were used to automate a Perkin-Elmer Model 13 spectrophotometer with a Hohlraum reflectivity attachment. Additional electronic circuitry was necessary for amplification, filtering, and debouncing. The computer was programmed to calculate spectral emittance from 1.7 to 14.7 micrometers and also total emittance versus temperature. Automation of the Hohlraum reflectometer reduced the time required to determine total emittance versus temperature from about three hours to about 40 minutes.

  15. Coal-shale interface detection

    NASA Technical Reports Server (NTRS)

    Broussard, P. H.; Burch, J. L.; Drost, E. J.; Stein, R. J. (Inventor)

    1979-01-01

    A penetrometer for coal-shale interface detection is presented. It is used with coal cutting equipment consisting of a reciprocating hammer, having an accelerometer mounted thereon to measure the impact of the hammer as it penetrates the ceiling or floor surface of a mine. Additionally, a pair of reflectometers simultaneously view the same surface, and the outputs from the accelerometer and reflectometers are detected and jointly registered to determine when an interface between coal and shale is being cut through.

  16. Tear film measurement by optical reflectometry technique

    PubMed Central

    Lu, Hui; Wang, Michael R.; Wang, Jianhua; Shen, Meixiao

    2014-01-01

    Abstract. Evaluation of tear film is performed by an optical reflectometer system with alignment guided by a galvanometer scanner. The reflectometer system utilizes optical fibers to deliver illumination light to the tear film and collect the film reflectance as a function of wavelength. Film thickness is determined by best fitting the reflectance-wavelength curve. The spectral reflectance acquisition time is 15 ms, fast enough for detecting film thickness changes. Fast beam alignment of 1 s is achieved by the galvanometer scanner. The reflectometer was first used to evaluate artificial tear film on a model eye with and without a contact lens. The film thickness and thinning rate have been successfully quantified with the minimum measured thickness of about 0.3 μm. Tear films in human eyes, with and without a contact lens, have also been evaluated. A high-contrast spectral reflectance signal from the precontact lens tear film is clearly observed, and the thinning dynamics have been easily recorded from 3.69 to 1.31 μm with lipid layer thickness variation in the range of 41 to 67 nm. The accuracy of the measurement is better than ±0.58% of the film thickness at an estimated tear film refractive index error of ±0.001. The fiber-based reflectometer system is compact and easy to handle. PMID:24500519

  17. Improved integrating-sphere throughput with a lens and nonimaging concentrator.

    PubMed

    Chenault, D B; Snail, K A; Hanssen, L M

    1995-12-01

    A reflectometer design utilizing an integrating sphere with a lens and nonimaging concentrator is described. Compared with previous designs where a collimator was used to restrict the detector field of view, the concentrator-lens combination significantly increases the throughput of the reflectometer. A procedure for designing lens-concentrators is given along with the results of parametric studies. The measured angular response of a lens-concentrator system is compared with ray-trace predictions and with the response of an ideal system.

  18. Microwave reflectometer ionization sensor

    NASA Technical Reports Server (NTRS)

    Seals, Joseph; Fordham, Jeffrey A.; Pauley, Robert G.; Simonutti, Mario D.

    1993-01-01

    The development of the Microwave Reflectometer Ionization Sensor (MRIS) Instrument for use on the Aeroassist Flight Experiment (AFE) spacecraft is described. The instrument contract was terminated, due to cancellation of the AFE program, subsequent to testing of an engineering development model. The MRIS, a four-frequency reflectometer, was designed for the detection and location of critical electron density levels in spacecraft reentry plasmas. The instrument would sample the relative magnitude and phase of reflected signals at discrete frequency steps across 4 GHz bandwidths centered at four frequencies: 20, 44, 95, and 140 GHz. The sampled data would be stored for later processing to calculate the distance from the spacecraft surface to the critical electron densities versus time. Four stepped PM CW transmitter receivers were located behind the thermal protection system of the spacecraft with horn antennas radiating and receiving through an insulating tile. Techniques were developed to deal with interference, including multiple reflections and resonance effects, resulting from the antenna configuration and operating environment.

  19. Distributed Fiber-Optic Sensors for Vibration Detection

    PubMed Central

    Liu, Xin; Jin, Baoquan; Bai, Qing; Wang, Yu; Wang, Dong; Wang, Yuncai

    2016-01-01

    Distributed fiber-optic vibration sensors receive extensive investigation and play a significant role in the sensor panorama. Optical parameters such as light intensity, phase, polarization state, or light frequency will change when external vibration is applied on the sensing fiber. In this paper, various technologies of distributed fiber-optic vibration sensing are reviewed, from interferometric sensing technology, such as Sagnac, Mach–Zehnder, and Michelson, to backscattering-based sensing technology, such as phase-sensitive optical time domain reflectometer, polarization-optical time domain reflectometer, optical frequency domain reflectometer, as well as some combinations of interferometric and backscattering-based techniques. Their operation principles are presented and recent research efforts are also included. Finally, the applications of distributed fiber-optic vibration sensors are summarized, which mainly include structural health monitoring and perimeter security, etc. Overall, distributed fiber-optic vibration sensors possess the advantages of large-scale monitoring, good concealment, excellent flexibility, and immunity to electromagnetic interference, and thus show considerable potential for a variety of practical applications. PMID:27472334

  20. Development of a spatially resolved reflectometer to monitor corrosion of solar reflectors

    NASA Astrophysics Data System (ADS)

    Sutter, Florian; Meyen, Stephanie; Heller, Peter; Pitz-Paal, Robert

    2013-06-01

    Solar reflectors for Concentrating Solar Power (CSP) concentrators require a high reflectance and high specularity over the whole solar spectrum. During their lifetime of at least 20 years, the reflectors must withstand harsh outdoor conditions without loosing their reflective properties. Currently, there are not many devices available to measure the specular reflectance. In this work a prototype of a specular reflectometer with spatial resolution has been developed. The major advantage of the prototype compared to other reflectometers is the possibility of measuring the specular reflectance on an extended measuring spot of more than 5 cm in diameter with a spatial resolution of 37 pixel/mm. Additionally, measurements can be taken at three different acceptance half angles (φ = 3.5, 6.0, and 12.5 mrad) and at three different wavelengths (λ = 410 nm, 500 nm, and 656 nm). This lab scale instrument can be employed to monitor degradation effects, such as corrosion spots, and evaluate their influence on the specular reflectance of solar mirror materials.

  1. Distributed Fiber-Optic Sensors for Vibration Detection.

    PubMed

    Liu, Xin; Jin, Baoquan; Bai, Qing; Wang, Yu; Wang, Dong; Wang, Yuncai

    2016-07-26

    Distributed fiber-optic vibration sensors receive extensive investigation and play a significant role in the sensor panorama. Optical parameters such as light intensity, phase, polarization state, or light frequency will change when external vibration is applied on the sensing fiber. In this paper, various technologies of distributed fiber-optic vibration sensing are reviewed, from interferometric sensing technology, such as Sagnac, Mach-Zehnder, and Michelson, to backscattering-based sensing technology, such as phase-sensitive optical time domain reflectometer, polarization-optical time domain reflectometer, optical frequency domain reflectometer, as well as some combinations of interferometric and backscattering-based techniques. Their operation principles are presented and recent research efforts are also included. Finally, the applications of distributed fiber-optic vibration sensors are summarized, which mainly include structural health monitoring and perimeter security, etc. Overall, distributed fiber-optic vibration sensors possess the advantages of large-scale monitoring, good concealment, excellent flexibility, and immunity to electromagnetic interference, and thus show considerable potential for a variety of practical applications.

  2. SuperADAM: Upgraded polarized neutron reflectometer at the Institut Laue-Langevin

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Devishvili, A.; Zhernenkov, K.; Institut Laue-Langevin, BP 156, 38042 Grenoble

    2013-02-15

    A new neutron reflectometer SuperADAM has recently been built and commissioned at the Institut Laue-Langevin, Grenoble, France. It replaces the previous neutron reflectometer ADAM. The new instrument uses a solid state polarizer/wavelength filter providing a highly polarized (up to 98.6%) monochromatic neutron flux of 8 Multiplication-Sign 10{sup 4} n cm{sup -2} s{sup -1} with monochromatization {Delta}{lambda}/{lambda}= 0.7% and angular divergence {Delta}{alpha}= 0.2 mrad. The instrument includes both single and position sensitive detectors. The position sensitive detector allows simultaneous measurement of specular reflection and off-specular scattering. Polarization analysis for both specular reflection and off-specular scattering is achieved using either mirror analyzersmore » or a {sup 3}He spin filter cell. High efficiency detectors, low background, and high flux provides a dynamic range of up to seven decades in reflectivity. Detailed specifications and the instrument capabilities are illustrated with examples of recently collected data in the fields of thin film magnetism and thin polymer films.« less

  3. SuperADAM: Upgraded polarized neutron reflectometer at the Institut Laue-Langevin

    NASA Astrophysics Data System (ADS)

    Devishvili, A.; Zhernenkov, K.; Dennison, A. J. C.; Toperverg, B. P.; Wolff, M.; Hjörvarsson, B.; Zabel, H.

    2013-02-01

    A new neutron reflectometer SuperADAM has recently been built and commissioned at the Institut Laue-Langevin, Grenoble, France. It replaces the previous neutron reflectometer ADAM. The new instrument uses a solid state polarizer/wavelength filter providing a highly polarized (up to 98.6%) monochromatic neutron flux of 8 × 104 n cm-2 s-1 with monochromatization Δλ/λ = 0.7% and angular divergence Δα = 0.2 mrad. The instrument includes both single and position sensitive detectors. The position sensitive detector allows simultaneous measurement of specular reflection and off-specular scattering. Polarization analysis for both specular reflection and off-specular scattering is achieved using either mirror analyzers or a 3He spin filter cell. High efficiency detectors, low background, and high flux provides a dynamic range of up to seven decades in reflectivity. Detailed specifications and the instrument capabilities are illustrated with examples of recently collected data in the fields of thin film magnetism and thin polymer films.

  4. SuperADAM: upgraded polarized neutron reflectometer at the Institut Laue-Langevin.

    PubMed

    Devishvili, A; Zhernenkov, K; Dennison, A J C; Toperverg, B P; Wolff, M; Hjörvarsson, B; Zabel, H

    2013-02-01

    A new neutron reflectometer SuperADAM has recently been built and commissioned at the Institut Laue-Langevin, Grenoble, France. It replaces the previous neutron reflectometer ADAM. The new instrument uses a solid state polarizer/wavelength filter providing a highly polarized (up to 98.6%) monochromatic neutron flux of 8 × 10(4) n cm(-2) s(-1) with monochromatization Δλ∕λ = 0.7% and angular divergence Δα = 0.2 mrad. The instrument includes both single and position sensitive detectors. The position sensitive detector allows simultaneous measurement of specular reflection and off-specular scattering. Polarization analysis for both specular reflection and off-specular scattering is achieved using either mirror analyzers or a (3)He spin filter cell. High efficiency detectors, low background, and high flux provides a dynamic range of up to seven decades in reflectivity. Detailed specifications and the instrument capabilities are illustrated with examples of recently collected data in the fields of thin film magnetism and thin polymer films.

  5. Development of the low-field side reflectometer for ITER

    NASA Astrophysics Data System (ADS)

    Muscatello, Christopher; Anderson, James; Gattuso, Anthony; Doyle, Edward; Peebles, William; Seraydarian, Raymond; Wang, Guiding; Kramer, Gerrit; Zolfaghari, Ali; Atomics Team, General; University of California Los Angeles Team; Princeton Plasma Physics Laboratory Team

    2017-10-01

    The Low-Field Side Reflectometer (LFSR) for ITER will provide real-time edge density profiles every 10 ms for feedback control and every 24 μs for physics evaluation. The spatial resolution will be better than 5 mm over 30 - 165 GHz, probing the scrape-off layer to the top of the pedestal in H-mode plasmas. An antenna configuration has been selected for measurements covering anticipated plasma elevations. Laboratory validation of diagnostic performance is underway using a LFSR transmission line (TL) mockup. The 40-meter TL includes circular corrugated waveguide, length calibration feature, Gaussian telescope, vacuum windows, containment membranes, and expansion joint. Transceiver modules coupled to the input of the TL provide frequency-modulated (FM) data for evaluation of performance as a monostatic reflectometer. Results from the mockup tests are presented and show that, with some further optimization, the LFSR will meet or exceed the measurement requirements for ITER. An update of the LFSR instrumentation design status is also presented with preliminary test results. Work supported by PPPL under subcontract S013252-A.

  6. Proof of Concept: Development of Snow Liquid Water Content Profiler Using CS650 Reflectometers at Caribou, ME, USA.

    PubMed

    Pérez Díaz, Carlos L; Muñoz, Jonathan; Lakhankar, Tarendra; Khanbilvardi, Reza; Romanov, Peter

    2017-03-21

    The quantity of liquid water in the snowpack defines its wetness. The temporal evolution of snow wetness's plays a significant role in wet-snow avalanche prediction, meltwater release, and water availability estimations and assessments within a river basin. However, it remains a difficult task and a demanding issue to measure the snowpack's liquid water content (LWC) and its temporal evolution with conventional in situ techniques. We propose an approach based on the use of time-domain reflectometry (TDR) and CS650 soil water content reflectometers to measure the snowpack's LWC and temperature profiles. For this purpose, we created an easily-applicable, low-cost, automated, and continuous LWC profiling instrument using reflectometers at the Cooperative Remote Sensing Science and Technology Center-Snow Analysis and Field Experiment (CREST-SAFE) in Caribou, ME, USA, and tested it during the snow melt period (February-April) immediately after installation in 2014. Snow Thermal Model (SNTHERM) LWC simulations forced with CREST-SAFE meteorological data were used to evaluate the accuracy of the instrument. Results showed overall good agreement, but clearly indicated inaccuracy under wet snow conditions. For this reason, we present two (for dry and wet snow) statistical relationships between snow LWC and dielectric permittivity similar to Topp's equation for the LWC of mineral soils. These equations were validated using CREST-SAFE in situ data from winter 2015. Results displayed high agreement when compared to LWC estimates obtained using empirical formulas developed in previous studies, and minor improvement over wet snow LWC estimates. Additionally, the equations seemed to be able to capture the snowpack state (i.e., onset of melt, medium, and maximum saturation). Lastly, field test results show advantages, such as: automated, continuous measurements, the temperature profiling of the snowpack, and the possible categorization of its state. However, future work should focus on improving the instrument's capability to measure the snowpack's LWC profile by properly calibrating it with in situ LWC measurements. Acceptable validation agreement indicates that the developed snow LWC, temperature, and wetness profiler offers a promising new tool for snow hydrology research.

  7. Simultaneous measurement of X-ray specular reflection and off-specular diffuse scattering from liquid surfaces using a two-dimensional pixel array detector: the liquid-interface reflectometer of BL37XU at SPring-8.

    PubMed

    Yano, Yohko F; Uruga, Tomoya; Tanida, Hajime; Toyokawa, Hidenori; Terada, Yasuko; Yamada, Hironari

    2010-07-01

    An X-ray reflectometer for simultaneous measurement of specular and off-specular reflection of liquid surfaces is described. The reflectometer, equipped with a two-dimensional single X-ray photon-counting pixel array detector obtained the full range of X-ray specular and off-specular reflections in an extremely short time (1 s). Both the specular and off-specular reflection of water exhibited good agreement with the predicted capillary-wave theory within the appropriate instrumental resolution. The approach is also demonstrated on an aqueous solution of 1-dodecyl-3-methylimidazolium chloride. The monolayer in which the dodecyl chain faces upwards and the Cl(-) anion locates next to the imidazolium ring formed on the water surface was found to be laterally homogeneous. The use of a pixel array detector will be particularly powerful for in situ measurements to investigate both out-of-plane and in-plane structures simultaneously, not only for liquid surfaces but also for other thin films.

  8. Design and Validation of a Ten-Port Waveguide Reflectometer Sensor: Application to Efficiency Measurement and Optimization of Microwave-Heating Ovens

    PubMed Central

    Pedreño-Molina, Juan L.; Monzó-Cabrera, Juan; Lozano-Guerrero, Antonio; Toledo-Moreo, Ana

    2008-01-01

    This work presents the design, manufacturing process, calibration and validation of a new microwave ten-port waveguide reflectometer based on the use of neural networks. This low-cost novel device solves some of the shortcomings of previous reflectometers such as non-linear behavior of power sensors, noise presence and the complexity of the calibration procedure, which is often based on complex mathematical equations. These problems, which imply the reduction of the reflection coefficient measurement accuracy, have been overcome by using a higher number of probes than usual six-port configurations and by means of the use of Radial Basis Function (RBF) neural networks in order to reduce the influence of noise and non-linear processes over the measurements. Additionally, this sensor can be reconfigured whenever some of the eight coaxial power detectors fail, still providing accurate values in real time. The ten-port performance has been compared against a high-cost measurement instrument such as a vector network analyzer and applied to the measurement and optimization of energy efficiency of microwave ovens, with good results. PMID:27873961

  9. Refractive and relativistic effects on ITER low field side reflectometer design.

    PubMed

    Wang, G; Rhodes, T L; Peebles, W A; Harvey, R W; Budny, R V

    2010-10-01

    The ITER low field side reflectometer faces some unique design challenges, among which are included the effect of relativistic electron temperatures and refraction of probing waves. This paper utilizes GENRAY, a 3D ray tracing code, to investigate these effects. Using a simulated ITER operating scenario, characteristics of the reflected millimeter waves after return to the launch plane are quantified as a function of a range of design parameters, including antenna height, antenna diameter, and antenna radial position. Results for edge/SOL measurement with both O- and X-mode polarizations using proposed antennas are reported.

  10. Development of Surfaces Optically Suitable for Flat Solar Panels

    NASA Technical Reports Server (NTRS)

    Desmet, D.; Jason, A.

    1978-01-01

    Three areas of research in the development of flat solar panels are described. (1) A reflectometer which can separately evaluate the spectral and diffuse reflectivities of surfaces was developed. The reflectometer has a phase locked detection system. (2) A coating composed of strongly bound copper oxide that is formed by an etching process performed on an aluminum alloy with high copper content was also developed. Because of this one step fabrication process, fabrication costs are expected to be small. (3) A literature search was conducted and conclusions on the required optical properties of flat plate solar collectors are presented.

  11. Development of frequency modulation reflectometer for Korea Superconducting Tokamak Advanced Research tokamak

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Seo, Seong-Heon; Wi, H. M.; Lee, W. R.

    2013-08-15

    Frequency modulation reflectometer has been developed to measure the plasma density profile of the Korea Superconducting Tokamak Advanced Research tokamak. Three reflectometers are operating in extraordinary polarization mode in the frequency range of Q band (33.6–54 GHz), V band (48–72 GHz), and W band (72–108 GHz) to measure the density up to 7 × 10{sup 19} m{sup −3} when the toroidal magnetic field is 2 T on axis. The antenna is installed inside of the vacuum vessel. A new vacuum window is developed by using 50 μm thick mica film and 0.1 mm thick gold gasket. The filter bank ofmore » low pass filter, notch filter, and Faraday isolator is used to reject the electron cyclotron heating high power at attenuation of 60 dB. The full frequency band is swept in 20 μs. The mixer output is directly digitized with sampling rate of 100 MSamples/s. The phase is obtained by using wavelet transform. The whole hardware and software system is described in detail and the measured density profile is presented as a result.« less

  12. Performance and data analysis aspects of the new DIII-D monostatic profile reflectometer system

    DOE PAGES

    Zeng, Lei; Peebles, William A.; Doyle, Edward J.; ...

    2014-08-07

    A new frequency-modulated (FMCW) profile reflectometer system, featuring a monostatic antenna geometry (using one microwave antenna for both launch and receive), has been installed on the DIII-D tokamak, providing a first experimental test of this measurement approach for profile reflectometry. Significant features of the new system are briefly described in this paper, including the new monostatic arrangement, use of overmoded, broadband transmission waveguide, and dual-polarization combination/demultiplexing. Updated data processing and analysis, and in-service performance aspects of the new monostatic profile reflectometer system are also presented. By using a raytracing code (GENRAY) to determine the approximate trajectory of the probe beam,more » the electron density (n e) profile can be successfully reconstructed with L-mode plasmas vertically shifted by more than 10 cm off the vessel midplane. Specifically, it is demonstrated that the new system has a capability to measure n e profiles with plasma vertical offsets of up to ±17 cm. Furthermore, examples are also presented of accurate, high time and spatial resolution density profile measurements made over a wide range of DIII-D conditions, e.g. the measured temporal evolution of the density profile across an L-H transition.« less

  13. The Lunar Prospector Discovery Mission: mission and measurement description.

    NASA Astrophysics Data System (ADS)

    Hubbard, G. S.; Binder, A. B.; Feldman, W.

    1998-06-01

    Lunar Prospector, the first competitively selected planetary mission in NASA's Discovery Program, is described with emphasis on the radiation spectrometer instrumentation and anticipated scientific data return. Scheduled to be launched in January 1998, the mission will conduct a one year orbital survey of the Moon's composition and structure. The suite of five instruments are outlined: neutron spectrometer, alpha particle spectrometer, gamma-ray spectrometer, electron reflectometer and magnetometer. Scientific requirements and measurement approach to detect water/ice to a sensitivity of 50 ppm (hydrogen), measure key elemental constituents, detect radioactive gas release events and accurately map the Moon's gravitational and magnetic fields are given. A brief overview of the programmatic accomplishments in meeting a tightly constrained schedule and budget is also provided.

  14. The Lunar Prospector discovery mission: mission and measurement description.

    NASA Astrophysics Data System (ADS)

    Hubbard, G. S.; Binder, A. B.; Feldman, W.

    Lunar Prospector, the first competitively selected planetary mission in NASA's discovery program, is described with emphasis on the radiation spectrometer instrumentation and anticipated scientific data return. Scheduled to be launched in January 1998, the mission will conduct a one year orbital survey of the moon's composition and structure. The suite of five instruments will be outlined: neutron spectrometer, alpha particle spectrometer, gamma-ray spectrometer, electron reflectometer and magnetometer. Scientific requirements and measurement approach to detect water ice to a sensitivity of 50 ppm (hydrogen), measure key elemental constituents, detect radioactive gas release events and accurately map the moon's gravitational and magnetic fields are given. A brief overview of the programmatic accomplishments in meeting a tightly constrained schedule and budget is also provided.

  15. Multi-point measurement using two-channel reflectometer with antenna switching for study of high-frequency fluctuations in GAMMA 10

    NASA Astrophysics Data System (ADS)

    Ikezoe, R.; Ichimura, M.; Okada, T.; Itagaki, J.; Hirata, M.; Sumida, S.; Jang, S.; Izumi, K.; Tanaka, A.; Yoshikawa, M.; Kohagura, J.; Sakamoto, M.; Nakashima, Y.

    2017-03-01

    A two-channel microwave reflectometer system with fast microwave antenna switching capability was developed and applied to the GAMMA 10 tandem mirror device to study high-frequency small-amplitude fluctuations in a hot mirror plasma. The fast switching of the antennas is controlled using PIN diode switches, which offers the significant advantage of reducing the number of high-cost microwave components and digitizers with high bandwidths and large memory that are required to measure the spatiotemporal behavior of the high-frequency fluctuations. The use of two channels rather than one adds the important function of a simultaneous two-point measurement in either the radial direction or the direction of the antenna array to measure the phase profile of the fluctuations along with the normal amplitude profile. The density fluctuations measured using this system clearly showed the high-frequency coherent fluctuations that are associated with Alfvén-ion-cyclotron (AIC) waves in GAMMA 10. A correlation analysis applied to simultaneously measured density fluctuations showed that the phase component that was included in a reflected microwave provided both high coherence and a clear phase difference for the AIC waves, while the amplitude component showed neither significant coherence nor clear phase difference. The axial phase differences of the AIC waves measured inside the hot plasma confirmed the formation of a standing wave structure. The axial variation of the radial profiles was evaluated and a clear difference was found among the AIC waves for the first time, which would be a key to clarify the unknown boundary conditions of the AIC waves.

  16. Direct measurement of density oscillation induced by a radio-frequency wave.

    PubMed

    Yamada, T; Ejiri, A; Shimada, Y; Oosako, T; Tsujimura, J; Takase, Y; Kasahara, H

    2007-08-01

    An O-mode reflectometer at a frequency of 25.85 GHz was applied to plasmas heated by the high harmonic fast wave (21 MHz) in the TST-2 spherical tokamak. An oscillation in the phase of the reflected microwave in the rf range was observed directly for the first time. In TST-2, the rf (250 kW) induced density oscillation depends mainly on the poloidal rf electric field, which is estimated to be about 0.2 kV/m rms by the reflectometer measurement. Sideband peaks separated in frequency by ion cyclotron harmonics from 21 MHz, and peaks at ion cyclotron harmonics which are suggested to be quasimodes generated by parametric decay, were detected.

  17. Measurement of two-dimensional thickness of micro-patterned thin film based on image restoration in a spectroscopic imaging reflectometer.

    PubMed

    Kim, Min-Gab; Kim, Jin-Yong

    2018-05-01

    In this paper, we introduce a method to overcome the limitation of thickness measurement of a micro-patterned thin film. A spectroscopic imaging reflectometer system that consists of an acousto-optic tunable filter, a charge-coupled-device camera, and a high-magnitude objective lens was proposed, and a stack of multispectral images was generated. To secure improved accuracy and lateral resolution in the reconstruction of a two-dimensional thin film thickness, prior to the analysis of spectral reflectance profiles from each pixel of multispectral images, the image restoration based on an iterative deconvolution algorithm was applied to compensate for image degradation caused by blurring.

  18. AND/R: Advanced neutron diffractometer/reflectometer for investigation of thin films and multilayers for the life sciences

    PubMed Central

    Dura, Joseph A.; Pierce, Donald J.; Majkrzak, Charles F.; Maliszewskyj, Nicholas C.; McGillivray, Duncan J.; Lösche, Mathias; O'Donovan, Kevin V.; Mihailescu, Mihaela; Perez-Salas, Ursula; Worcester, David L.; White, Stephen H.

    2011-01-01

    An elastic neutron scattering instrument, the advanced neutron diffractometer/reflectometer (AND/R), has recently been commissioned at the National Institute of Standards and Technology Center for Neutron Research. The AND/R is the centerpiece of the Cold Neutrons for Biology and Technology partnership, which is dedicated to the structural characterization of thin films and multilayers of biological interest. The instrument is capable of measuring both specular and nonspecular reflectivity, as well as crystalline or semicrystalline diffraction at wave-vector transfers up to approximately 2.20 Å−1. A detailed description of this flexible instrument and its performance characteristics in various operating modes are given. PMID:21892232

  19. A PC based time domain reflectometer for space station cable fault isolation

    NASA Technical Reports Server (NTRS)

    Pham, Michael; McClean, Marty; Hossain, Sabbir; Vo, Peter; Kouns, Ken

    1994-01-01

    Significant problems are faced by astronauts on orbit in the Space Station when trying to locate electrical faults in multi-segment avionics and communication cables. These problems necessitate the development of an automated portable device that will detect and locate cable faults using the pulse-echo technique known as Time Domain Reflectometry. A breadboard time domain reflectometer (TDR) circuit board was designed and developed at the NASA-JSC. The TDR board works in conjunction with a GRiD lap-top computer to automate the fault detection and isolation process. A software program was written to automatically display the nature and location of any possible faults. The breadboard system can isolate open circuit and short circuit faults within two feet in a typical space station cable configuration. Follow-on efforts planned for 1994 will produce a compact, portable prototype Space Station TDR capable of automated switching in multi-conductor cables for high fidelity evaluation. This device has many possible commercial applications, including commercial and military aircraft avionics, cable TV, telephone, communication, information and computer network systems. This paper describes the principle of time domain reflectometry and the methodology for on-orbit avionics utility distribution system repair, utilizing the newly developed device called the Space Station Time Domain Reflectometer (SSTDR).

  20. The multipurpose time-of-flight neutron reflectometer “Platypus” at Australia's OPAL reactor

    NASA Astrophysics Data System (ADS)

    James, M.; Nelson, A.; Holt, S. A.; Saerbeck, T.; Hamilton, W. A.; Klose, F.

    2011-03-01

    In this manuscript we describe the major components of the Platypus time-of-flight neutron reflectometer at the 20 MW OPAL reactor in Sydney, Australia. Platypus is a multipurpose spectrometer for the characterisation of solid thin films, materials adsorbed at the solid-liquid interface and free-liquid surfaces. It also has the capacity to study magnetic thin films using spin-polarised neutrons. Platypus utilises a white neutron beam ( λ=2-20 Å) that is pulsed using boron-coated disc chopper pairs; thus providing the capacity to tailor the wavelength resolution of the pulses to suit the system under investigation. Supermirror optical components are used to focus, deflect or spin-polarise the broad bandwidth neutron beams, and typical incident spectra are presented for each configuration. A series of neutron reflectivity datasets are presented, indicating the quality and flexibility of this spectrometer. Minimum reflectivity values of <10 -7 are observed; while maximum thickness values of 325 nm have been measured for single-component films and 483 nm for a multilayer system. Off-specular measurements have also been made to investigate in-plane features as opposed to those normal to the sample surface. Finally, the first published studies conducted using the Platypus time-of-flight neutron reflectometer are presented.

  1. GINA--a polarized neutron reflectometer at the Budapest Neutron Centre.

    PubMed

    Bottyán, L; Merkel, D G; Nagy, B; Füzi, J; Sajti, Sz; Deák, L; Endrőczi, G; Petrenko, A V; Major, J

    2013-01-01

    The setup, capabilities, and operation parameters of the neutron reflectometer GINA, the recently installed "Grazing Incidence Neutron Apparatus" at the Budapest Neutron Centre, are introduced. GINA, a dance-floor-type, constant-energy, angle-dispersive reflectometer is equipped with a 2D position-sensitive detector to study specular and off-specular scattering. Wavelength options between 3.2 and 5.7 Å are available for unpolarized and polarized neutrons. Spin polarization and analysis are achieved by magnetized transmission supermirrors and radio-frequency adiabatic spin flippers. As a result of vertical focusing by a five-element pyrolytic graphite monochromator, the reflected intensity from a 20 × 20 mm(2) sample has been doubled. GINA is dedicated to studies of magnetic films and heterostructures, but unpolarized options for non-magnetic films, membranes, and other surfaces are also provided. Shortly after its startup, reflectivity values as low as 3 × 10(-5) have been measured by the instrument. The instrument capabilities are demonstrated by a non-polarized and a polarized reflectivity experiment on a Si wafer and on a magnetic film of [(62)Ni/(nat)Ni](5) isotope-periodic layer composition. The facility is now open for the international user community. Its further development is underway establishing new sample environment options and spin analysis of off-specularly scattered radiation as well as further decreasing the background.

  2. Handheld directional reflectometer: an angular imaging device to measure BRDF and HDR in real time

    NASA Astrophysics Data System (ADS)

    Mattison, Phillip R.; Dombrowski, Mark S.; Lorenz, James M.; Davis, Keith J.; Mann, Harley C.; Johnson, Philip; Foos, Bryan

    1998-10-01

    Many applications require quantitative measurements of surface light scattering, including quality control on production lines, inspection of painted surfaces, inspection of field repairs, etc. Instruments for measuring surface scattering typically fall into two main categories, namely bidirectional reflectometers, which measure the angular distribution of scattering, and hemispherical directional reflectometers, which measure the total scattering into the hemisphere above the surface. Measurement of the bi-directional reflectance distribution function (BRDF) gives the greatest insight into how light is scattered from a surface. Measurements of BRDF, however, are typically very lengthy measurements taken by moving a source and detector to map the scattering. Since BRDF has four angular degrees of freedom, such measurements can require hours to days to complete. Instruments for measuring BRDF are also typically laboratory devices, although a field- portable bi-directional reflectometer does exist. Hemispherical directional reflectance (HDR) is a much easier measurement to make, although care must be taken to use the proper methodology when measuring at wavelengths beyond 10 micrometer, since integrating spheres (typically used to make such measurements) are very energy inefficient and lose their integrating properties at very long wavelengths. A few field- portable hemispherical directional reflectometers do exist, but typically measure HDR only at near-normal angles. Boeing Defense and Space Group and Surface Optics Corporation, under a contract from the Air Force Research Laboratory, have developed a new hand-held instrument capable of measuring both BRDF and HDR using a unique, patented angular imaging technique. A combination of an hemi-ellipsoidal mirror and an additional lens translate the angular scatter from a surface into a two-dimensional spatial distribution, which is recorded by an imaging array. This configuration fully maps the scattering from a half-hemisphere above the surface with more than 30,000 angularly-resolved points and update rates to 60 measurements per second. The instrument then computes HDR from the measured BDR. For ease of use, the instrument can also compare both the BRDF and HDR to preset limits, generating a Pass/Fail indicator for HDR and a high-acceptable-low image display of BRDF. Beam incidence elevation is variable from normal incidence ((theta) equals 0 degrees) to 5 degrees off grazing ((theta) equals 85 degrees), while scattering is measured to nearly 90 degrees off normal. Such capability is extremely important for any application requiring knowledge of surface appearance at oblique viewing angles. The current instrument operates over the range of 3 micrometer to 12 micrometer, with extension into the visible band possible.

  3. Lunar Prospector: developing a very low cost planetary mission.

    NASA Astrophysics Data System (ADS)

    Hubbard, G. S.

    Lunar Prospector, the first competitively selected planetary mission in NASA's Discovery Program, is described with emphasis on the lessons learned from managing a very low cost project. Insights into government-industry teaming, project management, contractual arrangements, schedule and budget reserve approach are discussed. The mission is conducting an orbital survey of the Moon's composition and structure. A mission overview and scientific data return is briefly described in the context of low cost mission development. The suite of five instruments is outlined: neutron spectrometer (NS), alpha particle spectrometer (APS), gamma ray spectrometer (GRS), magnetometer (MAG) and an electron reflectometer (ER). Scientific requirements and measurement approaches to detect water ice to a sensitivity of 50 ppm (hydrogen), measure key elemental constituents, detect gas release events and accurately map the Moon's gravitational and magnetic fields are described.

  4. Front-end antenna system design for the ITER low-field-side reflectometer system using GENRAY ray tracing.

    PubMed

    Wang, G; Doyle, E J; Peebles, W A

    2016-11-01

    A monostatic antenna array arrangement has been designed for the microwave front-end of the ITER low-field-side reflectometer (LFSR) system. This paper presents details of the antenna coupling coefficient analyses performed using GENRAY, a 3-D ray tracing code, to evaluate the plasma height accommodation capability of such an antenna array design. Utilizing modeled data for the plasma equilibrium and profiles for the ITER baseline and half-field scenarios, a design study was performed for measurement locations varying from the plasma edge to inside the top of the pedestal. A front-end antenna configuration is recommended for the ITER LFSR system based on the results of this coupling analysis.

  5. Distributed fiber sensing system with wide frequency response and accurate location

    NASA Astrophysics Data System (ADS)

    Shi, Yi; Feng, Hao; Zeng, Zhoumo

    2016-02-01

    A distributed fiber sensing system merging Mach-Zehnder interferometer and phase-sensitive optical time domain reflectometer (Φ-OTDR) is demonstrated for vibration measurement, which requires wide frequency response and accurate location. Two narrow line-width lasers with delicately different wavelengths are used to constitute the interferometer and reflectometer respectively. A narrow band Fiber Bragg Grating is responsible for separating the two wavelengths. In addition, heterodyne detection is applied to maintain the signal to noise rate of the locating signal. Experiment results show that the novel system has a wide frequency from 1 Hz to 50 MHz, limited by the sample frequency of data acquisition card, and a spatial resolution of 20 m, according to 200 ns pulse width, along 2.5 km fiber link.

  6. A simultaneous multiple angle-wavelength dispersive X-ray reflectometer using a bent-twisted polychromator crystal

    PubMed Central

    Matsushita, Tadashi; Arakawa, Etsuo; Voegeli, Wolfgang; Yano, Yohko F.

    2013-01-01

    An X-ray reflectometer has been developed, which can simultaneously measure the whole specular X-ray reflectivity curve with no need for rotation of the sample, detector or monochromator crystal during the measurement. A bent-twisted crystal polychromator is used to realise a convergent X-ray beam which has continuously varying energy E (wavelength λ) and glancing angle α to the sample surface as a function of horizontal direction. This convergent beam is reflected in the vertical direction by the sample placed horizontally at the focus and then diverges horizontally and vertically. The normalized intensity distribution of the reflected beam measured downstream of the specimen with a two-dimensional pixel array detector (PILATUS 100K) represents the reflectivity curve. Specular X-ray reflectivity curves were measured from a commercially available silicon (100) wafer, a thin gold film coated on a silicon single-crystal substrate and the surface of liquid ethylene glycol with data collection times of 0.01 to 1000 s using synchrotron radiation from a bending-magnet source of a 6.5 GeV electron storage ring. A typical value of the simultaneously covered range of the momentum transfer was 0.01–0.45 Å−1 for the silicon wafer sample. The potential of this reflectometer for time-resolved X-ray studies of irreversible structural changes is discussed. PMID:23254659

  7. High Resolution Millimeter Wave Inspecting of the Orbiter Acreage Heat Tiles of the Space Shuttle

    NASA Technical Reports Server (NTRS)

    Case, J. T.; Khakovsky, S.; Zoughi, r.; Hepburn, F.

    2007-01-01

    Presence of defects such as disbonds, delaminations, impact damage, in thermal protection systems can significantly reduce safety of the Space Shuttle and its crew. The physical cause of Space Shuttle Columbia's catastrophic failure was a breach in its thermal protection system, caused by a piece of external tank insulating foam separating from the external tank and striking the leading edge of the left wing of the orbiter. There is an urgent need for a rapid, robust and life-circle oriented nondestructive testing (NDT) technique capable of inspecting the external tank insulating foam as well as the orbiter's protective (acreage) heat tiles and its fuselage prior and subsequent to a launch. Such a comprehensive inspection technique enables NASA to perform life-cycle inspection on critical components of the orbiter and its supporting hardware. Consequently, NASA Marshall Space Flight Center initiated an investigation into several potentially viable NDT techniques for this purpose. Microwave and millimeter wave NDT methods have shown great potential to achieve these goals. These methods have been successfully used to produce images of the interior of various complex, thick and thin external tank insulating foam structures for real focused reflectometer at operating frequency from 50-100 GHz and for synthetic aperture techniques at Ku-band (12-18 GHz) and K-band (18-26 GHz). Preliminary results of inspecting heat tile specimens show that increasing resolution of the measurement system is an important issue. This paper presents recent results of an investigation for the purpose of detecting anomalies such as debonds and corrosion in metal substrate in complex multi-sectioned protective heat tile specimens using a real focused 150 GHz (D-band) reflectometer and wide-band millimeter wave holography at 33-50, GHz (Q-band).

  8. Developments in the realization of diffuse reflectance scales at NPL

    NASA Astrophysics Data System (ADS)

    Chunnilall, Christopher J.; Clarke, Frank J. J.; Shaw, Michael J.

    2005-08-01

    The United Kingdom scales for diffuse reflectance are realized using two primary instruments. In the 360 nm to 2.5 μm spectral region the National Reference Reflectometer (NRR) realizes absolute measurement of reflectance and radiance factor by goniometric measurements. Hemispherical reflectance scales are obtained through the spatial integration of these goniometric measurements. In the mid-infrared region (2.5 μm - 55 μm) the hemispherical reflectance scale is realized by the Absolute Hemispherical Reflectometer (AHR). This paper describes some of the uncertainties resulting from errors in aligning the NRR and non-ideality in sample topography, together with its use to carry out measurements in the 1 - 1.6 μm region. The AHR has previously been used with grating spectrometers, and has now been coupled to a Fourier transform spectrometer.

  9. Novel mono-static arrangement of the ASDEX Upgrade high field side reflectometers compatible with electron cyclotron resonance heating stray radiation.

    PubMed

    Silva, A; Varela, P; Meneses, L; Manso, M

    2012-10-01

    The ASDEX Upgrade frequency modulated continuous wave broadband reflectometer system uses a mono-static antenna configuration with in-vessel hog-horns and 3 dB directional couplers. The operation of the new electron cyclotron resonance heating (ECRH) launcher and the start of collective Thomson scattering experiments caused several events where the fragile dummy loads inside the high field side directional couplers were damaged, due to excessive power resulting from the ECRH stray fields. In this paper, we present a non-conventional application of the existing three-port directional coupler that hardens the system to the ECRH stray fields and at the same time generates the necessary reference signal. Electromagnetic simulations and laboratory tests were performed to validate the proposed solution and are compared with the in-vessel calibration tests.

  10. Invited Article: Polarization ``Down Under'': The polarized time-of-flight neutron reflectometer PLATYPUS

    NASA Astrophysics Data System (ADS)

    Saerbeck, T.; Klose, F.; Le Brun, A. P.; Füzi, J.; Brule, A.; Nelson, A.; Holt, S. A.; James, M.

    2012-08-01

    This review presents the implementation and full characterization of the polarization equipment of the time-of-flight neutron reflectometer PLATYPUS at the Australian Nuclear Science and Technology Organisation (ANSTO). The functionality and efficiency of individual components are evaluated and found to maintain a high neutron beam polarization with a maximum of 99.3% through polarizing Fe/Si supermirrors. Neutron spin-flippers with efficiencies of 99.7% give full control over the incident and scattered neutron spin direction over the whole wavelength spectrum available in the instrument. The first scientific experiments illustrate data correction mechanisms for finite polarizations and reveal an extraordinarily high reproducibility for measuring magnetic thin film samples. The setup is now fully commissioned and available for users through the neutron beam proposal system of the Bragg Institute at ANSTO.

  11. Invited article: polarization "down under": the polarized time-of-flight neutron reflectometer PLATYPUS.

    PubMed

    Saerbeck, T; Klose, F; Le Brun, A P; Füzi, J; Brule, A; Nelson, A; Holt, S A; James, M

    2012-08-01

    This review presents the implementation and full characterization of the polarization equipment of the time-of-flight neutron reflectometer PLATYPUS at the Australian Nuclear Science and Technology Organisation (ANSTO). The functionality and efficiency of individual components are evaluated and found to maintain a high neutron beam polarization with a maximum of 99.3% through polarizing Fe/Si supermirrors. Neutron spin-flippers with efficiencies of 99.7% give full control over the incident and scattered neutron spin direction over the whole wavelength spectrum available in the instrument. The first scientific experiments illustrate data correction mechanisms for finite polarizations and reveal an extraordinarily high reproducibility for measuring magnetic thin film samples. The setup is now fully commissioned and available for users through the neutron beam proposal system of the Bragg Institute at ANSTO.

  12. Status of the Signals of Opportunity Airborne Demonstrator (SoOp-AD)

    NASA Technical Reports Server (NTRS)

    Garrison, Jim; Lin, Yao-Cheng; Piepmeier, Jeff; Knuble, Joe; Hersey, Ken; Du Toit, Cornelus; Joseph, Alicia; Deshpande, Manohar; Alikakos, George; O'Brien, Steve; hide

    2016-01-01

    Root zone soil moisture (RZSM) is not directly measured by any current satellite instrument, despite its importance as a key link between surface hydrology and deeper processes. Presently, model assimilation of surface measurements or indirect estimates using other methods must be used to estimate this value. Signals of Opportunity (SoOp) methods, exploiting reflected P- and S-band communication satellite signals, have many of the benefits of both active and passive microwave remote sensing. Reutilization of active transmitters, with forward-scattering geometry, presents a strong reflected signal even at orbital altitudes. Microwave radiometry is advantageous as it measures emissivity, which is directly related to dielectric constant and sensitive to water content of soil. Synthetic aperture radar (SAR) is used in P-band (400 MHz) for soil moisture and biomass, but faces issues in obtaining permission to transmit due to spectrum regulations, particularly over North America and Europe. A primary advantage of SAR is excellent spatial resolution. Signals-of-opportunity (SoOp) reflectometry provides a good compromise between radiometry and SAR by providing decent sensitivity and special resolution for RZSM measurements without issues of spectrum access. Further, a SoOp instrument would not be limited to operating in only a few protected frequencies and is also expected to have less susceptibility to radio-frequency interference (RFI). Although advantageous if available, SoOp techniques do not require the ability to demodulate or decode the communication signals. The SoOp instrument is receive only and therefore requires much less electrical power than a SAR and is more similar to a radiometer in receiver architecture. These unique features of SoOp circumvent past obstacles to a spaceborne P-band remote sensing mission and have the potential to enable new RZSM measurements that are not possible with present technology. We will present the latest development status of a SoOp reflectometer airborne demonstrator (SoOp-AD) operating at 250 MHz to take advantage of existing communication satellite. The instrument is currently in laboratory integration and test.

  13. Passive Wireless Vibration Sensing for Measuring Aerospace Structural Flutter

    NASA Technical Reports Server (NTRS)

    Wilson, William C.; Moore, Jason P.

    2017-01-01

    To reduce energy consumption, emissions, and noise, NASA is exploring the use of high aspect ratio wings on subsonic aircraft. Because high aspect ratio wings are susceptible to flutter events, NASA is also investigating methods of flutter detection and suppression. In support of that work a new remote, non-contact method for measuring flutter-induced vibrations has been developed. The new sensing scheme utilizes a microwave reflectometer to monitor the reflected response from an aeroelastic structure to ultimately characterize structural vibrations. To demonstrate the ability of microwaves to detect flutter vibrations, a carbon fiber-reinforced polymer (CFRP) composite panel was vibrated at various frequencies from 1Hz to 130Hz. The reflectometer response was found to closely resemble the sinusoidal response as measured with an accelerometer up to 100 Hz. The data presented demonstrate that microwaves can be used to measure flutter-induced aircraft vibrations.

  14. Reflectometer for pseudo-Brewster angle spectrometry (BAIRS)

    NASA Astrophysics Data System (ADS)

    Potter, Roy F.

    2000-10-01

    A simple, robust reflectometer, pre-set for several angles of incidence (AOI), has been designed and used for determining the optical parameters of opaque samples having a specular surface. A single, linear polarizing element permits the measurement of perpendicular(s) and parallel (p) reflectence at each AOI. The BAIRS algorithm determines the empirical optical parameters for the subject surface at the pseudo-Brewster AOI, based on the measurement of p/s at two AOI's and, in turn the optical constants n and k (or (epsilon) 1 and (epsilon) 2). Radiation sources in current use, are a stabilized tungsten-halide lamp or a deuterium lamp for the visible and near UV spectral regions. Silica fiber optics and lenses deliver input and output radiation from the source and to a CCD array scanned diffraction spectrometer. Results for a sample of GaAs will be presented along with a discussion of dispersion features in the optical constant spectra.

  15. Photoconductive circuit element reflectometer

    DOEpatents

    Rauscher, Christen

    1990-01-01

    A photoconductive reflectometer for characterizing semiconductor devices at millimeter wavelength frequencies where a first photoconductive circuit element (PCE) is biased by a direct current voltage source and produces short electrical pulses when excited into conductance by short first laser light pulses. The electrical pulses are electronically conditioned to improve the frequency related amplitude characteristics of the pulses which thereafter propagate along a transmission line to a device under test. Second PCEs are connected along the transmission line to sample the signals on the transmission line when excited into conductance by short second laser light pulses, spaced apart in time a variable period from the first laser light pulses. Electronic filters connected to each of the second PCEs act as low-pass filters and remove parasitic interference from the sampled signals and output the sampled signals in the form of slowed-motion images of the signals on the transmission line.

  16. Photoconductive circuit element reflectometer

    DOEpatents

    Rauscher, C.

    1987-12-07

    A photoconductive reflectometer for characterizing semiconductor devices at millimeter wavelength frequencies where a first photoconductive circuit element (PCE) is biased by a direct current voltage source and produces short electrical pulses when excited into conductance by short first laser light pulses. The electrical pulses are electronically conditioned to improve the frequency related amplitude characteristics of the pulses which thereafter propagate along a transmission line to a device under test. Second PCEs are connected along the transmission line to sample the signals on the transmission line when excited into conductance by short second laser light pulses, spaced apart in time a determinable period from the first laser light pulses. Electronic filters connected to each of the second PCEs act as low-pass filters and remove parasitic interference from the sampled signals and output the sampled signals in the form of slowed-motion images of the signals on the transmission line. 4 figs.

  17. A Computer Aided Broad Band Impedance Matching Technique Using a Comparison Reflectometer. Ph.D. Thesis

    NASA Technical Reports Server (NTRS)

    Gordy, R. S.

    1972-01-01

    An improved broadband impedance matching technique was developed. The technique is capable of resolving points in the waveguide which generate reflected energy. A version of the comparison reflectometer was developed and fabricated to determine the mean amplitude of the reflection coefficient excited at points in the guide as a function of distance, and the complex reflection coefficient of a specific discontinuity in the guide as a function of frequency. An impedance matching computer program was developed which is capable of impedance matching the characteristics of each disturbance independent of other reflections in the guide. The characteristics of four standard matching elements were compiled, and their associated curves of reflection coefficient and shunt susceptance as a function of frequency are presented. It is concluded that an economical, fast, and reliable impedance matching technique has been established which can provide broadband impedance matches.

  18. New signal processing technique for density profile reconstruction using reflectometry.

    PubMed

    Clairet, F; Ricaud, B; Briolle, F; Heuraux, S; Bottereau, C

    2011-08-01

    Reflectometry profile measurement requires an accurate determination of the plasma reflected signal. Along with a good resolution and a high signal to noise ratio of the phase measurement, adequate data analysis is required. A new data processing based on time-frequency tomographic representation is used. It provides a clearer separation between multiple components and improves isolation of the relevant signals. In this paper, this data processing technique is applied to two sets of signals coming from two different reflectometer devices used on the Tore Supra tokamak. For the standard density profile reflectometry, it improves the initialization process and its reliability, providing a more accurate profile determination in the far scrape-off layer with density measurements as low as 10(16) m(-1). For a second reflectometer, which provides measurements in front of a lower hybrid launcher, this method improves the separation of the relevant plasma signal from multi-reflection processes due to the proximity of the plasma.

  19. Fiber cavity ring-down using an optical time-domain reflectometer

    NASA Astrophysics Data System (ADS)

    Passos, D. J.; Silva, S. O.; Fernandes, J. R. A.; Marques, M. B.; Frazão, O.

    2014-12-01

    This work presented a demonstration of the potential for a fiber based cavity ring-down (CRD) using an optical time-domain reflectometer (OTDR). The OTDR was used to send the impulses down into about 20 km of a standard single optical fiber, at the end of which the fiber cavity ring-down was placed. The OTDR measured no appreciable losses, so other CRDs multiplexed could be spliced in parallel along the same optical fiber. To demonstrate the behavior and sensitivity of the proposed configuration, a displacement sensor based on a fiber taper with a diameter of 50 μm was placed inside the fiber loop, and the induced losses were measured on the CRD signal — a sensitivity of 11.8 ± 0.5 μs/mm was achieved. The dynamic range of the sensing head used in this configuration was about 2 mm. Finally, this work was also compared with different works published in the literature.

  20. Reflectometry diagnostics on TCV

    NASA Astrophysics Data System (ADS)

    Molina Cabrera, Pedro; Coda, Stefano; Porte, Laurie; Offeddu, Nicola; Tcv Team

    2017-10-01

    Both profile reflectometer and Doppler back-scattering (DBS) diagnostics are being developed for the TCV Tokamak using a steerable quasi-optical launcher and universal polarizers. First results will be presented. A pulse reflectometer is being developed to complement Thomson Scattering measurements of electron density, greatly increasing temporal resolution and also effectively enabling fluctuation measurements. Pulse reflectometry consists of sending short pulses of varying frequency and measuring the roundtrip group-delay with precise chronometers. A fast arbitrary waveform generator is used as a pulse source feeding frequency multipliers that bring the pulses to V-band. A DBS diagnostic is currently operational in TCV. DBS may be used to infer the perpendicular velocity and wave number spectrum of electron density fluctuations in the 3-15 cm-1 wave-number range. Off-the-shelf transceiver modules, originally used for VNA measurements, are being used in a Doppler radar configuration. See author list of S. Coda et al., 2017 Nucl. Fusion 57 102011.

  1. Effect of Various Finishing Procedures on the Reflectivity (Shine) of Tooth Enamel - An In-vitro Study.

    PubMed

    Patil, Harshal Ashok; Chitko, Shrikant Shrinivas; Kerudi, Veerendra Virupaxappa; Maheshwari, Amit Ratanlal; Patil, Neeraj Suresh; Tekale, Pawankumar Dnyandeo; Gore, Ketan Ashorao; Zope, Amit Ashok

    2016-08-01

    Reflectivity of an object is a good parameter for surface finish. As the patient evaluates finishing as a function of gloss/reflectivity/shine an attempt is made here to evaluate changes in surface finish with custom made reflectometer. The aim of the present study was to study the effect of various procedures during orthodontic treatment on the shine of enamel, using a custom made reflectometer. Sixty one extracted premolars were collected and each tooth was mounted on acrylic block. Reflectivity of the teeth was measured as compared to standard before any procedure. One tooth was kept as standard throughout the study. Sixty teeth were acid etched. Reflectivity was measured on custom made reflectometer and readings recorded. Same procedure was repeated after debonding. Then 60 samples were divided into three groups: Group 1 - Tungsten Carbide, Group 2 - Astropol, Group 3- Sof-Lex disc depending upon the finishing method after debonding and reflectivity was measured. The mean percentage of reflectivity after acid etching was 31.4%, debonding 45.5%, Tungsten carbide bur finishing (Group 1) was 58.3%, Astropol (Group 2) 72.8%, and Sof-Lex disc (Group 3) 84.4% as that to the standard. There was statistically very highly significant (p<0.001) difference in reflectivity restored by the three finishing materials in the study. Thus, the light reflection was better in Group 3> Group 2> Group 1. The primary goal was to restore the enamel to its original state after orthodontic treatment. The methods tested in this study could not restore the original enamel reflectivity.

  2. Investigation clogging dynamic of permeable pavement systems using embedded sensors

    NASA Astrophysics Data System (ADS)

    Razzaghmanesh, Mostafa; Borst, Michael

    2018-02-01

    Permeable pavement is a stormwater control measure commonly selected in both new and retrofit applications. However, there is limited information about the clogging mechanism of these systems that effects the infiltration. A permeable pavement site located at the Seitz Elementary School, on Fort Riley, Kansas was selected for this study. An 80-space parking lot was built behind the school as part of an EPA collaboration with the U.S. Army. The parking lot design includes a permeable interlocking concrete pavement section along the downgradient edge. This study monitored the clogging progress of the pavement section using twelve water content reflectometers and three buried tipping bucket rain gauges. This clogging dynamic investigation was divided into three stages namely pre-clogged, transitional, and clogged. Recorded initial relative water content of all three stages were significantly and negatively correlated to antecedent dry weather periods with stronger correlations during clogged conditions. The peak relative water content correlation with peak rainfall 10-min intensity was significant for the water content reflectometers located on the western edge away from the eastern edge; this correlation was strongest during transition stage. Once clogged, rainfall measurements no longer correlated with the buried tipping bucket rain gauges. Both water content reflectometers and buried tipping bucket rain gauges showed the progress of surface clogging. For every 6 mm of rain, clogging advanced 1 mm across the surface. The results generally support the hypothesis that the clogging progresses from the upgradient to the downgradient edge. The magnitude of the contributing drainage area and rainfall characteristics are effective factors on rate and progression of clogging.

  3. Radiometric Calibration Techniques for Signal-of-Opportunity Reflectometers

    NASA Technical Reports Server (NTRS)

    Piepmeier, Jeffrey R.; Shah, Rashmi; Deshpande, Manohar; Johnson, Carey

    2014-01-01

    Bi-static reflection measurements utilizing global navigation satellite service (GNSS) or other signals of opportunity (SoOp) can be used to sense ocean and terrestrial surface properties. End-to-end calibration of GNSS-R has been performed using well-characterized reflection surface (e.g., water), direct path antenna, and receiver gain characterization. We propose an augmented approach using on-board receiver electronics for radiometric calibration of SoOp reflectometers utilizing direct and reflected signal receiving antennas. The method calibrates receiver and correlator gains and offsets utilizing a reference switch and common noise source. On-board electronic calibration sources, such as reference switches, noise diodes and loop-back circuits, have shown great utility in stabilizing total power and correlation microwave radiometer and scatterometer receiver electronics in L-band spaceborne instruments. Application to SoOp instruments is likely to bring several benefits. For example, application to provide short and long time scale calibration stability of the direct path channel, especially in low signal-to-noise ratio configurations, is directly analogous to the microwave radiometer problem. The direct path channel is analogous to the loopback path in a scatterometer to provide a reference of the transmitted power, although the receiver is independent from the reflected path channel. Thus, a common noise source can be used to measure the gain ratio of the two paths. Using these techniques long-term (days to weeks) calibration stability of spaceborne L-band scatterometer and radiometer has been achieved better than 0.1. Similar long-term stability would likely be needed for a spaceborne reflectometer mission to measure terrestrial properties such as soil moisture.

  4. Coincident Retrieval of Ocean Surface Roughness and Salinity Using Airborne and Satellite Microwave Radiometry and Reflectometry Measurements during the Carolina Offshore (Caro) Experiment.

    NASA Astrophysics Data System (ADS)

    Burrage, D. M.; Wesson, J. C.; Wang, D. W.; Garrison, J. L.; Zhang, H.

    2017-12-01

    The launch of the Cyclone Global Navigation Satellite System (CYGNSS) constellation of 8 microsats carrying GPS L-band reflectometers on 15 Dec., 2016, and continued operation of the L-band radiometer on the European Space Agency (ESA) Soil Moisture and Ocean Salinity (SMOS) satellite, allow these complementary technologies to coincidentally retrieve Ocean surface roughness (Mean Square Slope, MSS), Surface Wind speed (WSP), and Sea Surface Salinity (SSS). The Carolina Offshore (Caro) airborne experiment was conducted jointly by NRL SSC and Purdue University from 7-11 May, 2017 with the goal of under-flying CYGNSS and SMOS and overflying NOAA buoys, to obtain high-resolution reflectometer and radiometer data for combined retrieval of MSS, SSS and WSP on the continental shelf. Airborne instruments included NRL's Salinity Temperature and Roughness Remote Scanner (STARRS) L-, C- and IR-band radiometer system, and a 4-channel dual-pol L-band (GPS) and S-band (XM radio) reflectometer, built by Purdue University. Flights either crossed NOAA buoys on various headings, or intersected with specular point ground tracks at predicted CYGNSS overpass times. Prevailing winds during Caro were light to moderate (1-8 m/s), so specular returns dominated the reflectometer Delay Doppler Maps (DDMs), and MSS was generally low. In contrast, stronger winds (1-12 m/s) and rougher seas (wave heights 1-5 m) were experienced during the preceding Maine Offshore (Maineo) experiment in March, 2016. Several DDM observables were used to retrieve MSS and WSP, and radiometer brightness temperatures produced Sea Surface Temperature (SST), SSS and also WSP estimates. The complementary relationship of Kirchoff's formula e+r=1, between radiometric emissivity, e, and reflectivity, r, was exploited to seek consistent estimates of MSS, and use it to correct the SSS retrievals for sea surface roughness effects. The relative performance and utility of the various airborne and satellite retrieval algorithms were assessed, and the coincident buoy, aircraft and satellite retrievals of MSS, WSP and SSS were compared. During Caro WSP from the different instruments generally agreed. Some anomalously high wind retrievals found here and elsewhere in current CYGNSS Level 2 data may yield to the science team's recent L1 calibration revision.

  5. Non-destructive phase and intensity distributed measurements of the nonlinear stage of modulation instability in optical fibers

    NASA Astrophysics Data System (ADS)

    Mussot, Arnaud; Naveau, Corentin; Szriftgiser, Pascal; Copie, François; Kudlinski, Alexandre; Conforti, Matteo; Trillo, Stefano

    2018-02-01

    We report a novel experimental setup to perform distributed characterization in intensity and phase of the nonlinear stage of modulation instability by means of a non-invasive experimental setup : a heterodyne time domain reflectometer.

  6. A novel reflectometer for relative reflectance measurements of CCDs

    NASA Astrophysics Data System (ADS)

    Hart, Murdock; Barkhouser, Robert H.; Gunn, James E.; Smee, Stephen A.

    2016-07-01

    The high quantum efficiencies (QE) of backside illuminated charge coupled devices (CCD) has ushered in the age of the large scale astronomical survey. The QE of these devices can be greater than 90%, and is dependent upon the operating temperature, device thickness, backside charging mechanisms, and anti-reflection (AR) coatings. But at optical wavelengths the QE is well approximated as one minus the reflectance, thus the measurement of the backside reflectivity of these devices provides a second independent measure of their QE. We have designed and constructed a novel instrument to measure the relative specular reflectance of CCD detectors, with a significant portion of this device being constructed using a 3D fused deposition model (FDM) printer. This device implements both a monitor and measurement photodiode to simultaneously collect in- cident and reflected measurements reducing errors introduced by the relative reflectance calibration process. While most relative reflectometers are highly dependent upon a precisely repeatable target distance for accurate measurements, we have implemented a method of measurement which minimizes these errors. Using the reflectometer we have measured the reflectance of two types of Hamamatsu CCD detectors. The first device is a Hamamatsu 2k x 4k backside illuminated high resistivity p-type silicon detector which has been optimized to operate in the blue from 380 nm - 650 nm. The second detector being a 2k x 4k backside illuminated high resistivity p-type silicon detector optimized for use in the red from 640 nm - 960 nm. We have not only been able to measure the reflectance of these devices as a function of wavelength we have also sampled the reflectance as a function of position on the device, and found a reflection gradient across these devices.

  7. On-farm quick tests for estimating nitrogen in dairy manure.

    PubMed

    Van Kessel, J S; Reeves, J B

    2000-08-01

    Manure nutrient analyses performed rapidly on the farm could be useful for nutrient management programs. The objective of this experiment was to evaluate six quick tests for their accuracy in estimating total manure N or NH4+-N. The quick tests included the hydrometer, electrical conductivity meter and pen, reflectometer, Agros N Meter, and Quantofix-N-Volumeter. The hydrometer was used to estimate total N, while the remaining tests were used to estimate NH4+-N. Samples (107) were collected from dairy farms in five northeastern states. Samples were analyzed for total N and NH4+-N by traditional laboratory methods and using each of the quick tests. Manure compositions ranged from 1.4 to 38.6% dry matter (DM), 0.9 to 9.5 kg/m3 total N, and 0.3 to 4.7 kg/m3 NH4+-N. The estimated concentration of total N or NH4+-N determined by each quick test was regressed against laboratory-determined values. The hydrometer did not estimate total N accurately. The strongest relationship for estimation of NH4+-N was with the Quantofix-N-Volumeter followed by the Agros N Meter, the reflectometer, and the electrical conductivity meter and pen. When the samples were split into high (>12%) and low (< or =12%) DM groups, in all cases the r2 for the regression equation was higher for the low DM group than for the high DM group. The Agros N Meter, the reflectometer, and the conductivity meter and pen did not perform well for the high DM group. These data indicate that several quick tests are viable options for measuring NH4+-N concentrations in dairy slurries and solids.

  8. SPEAR — ToF neutron reflectometer at the Los Alamos Neutron Science Center

    NASA Astrophysics Data System (ADS)

    Dubey, M.; Jablin, M. S.; Wang, P.; Mocko, M.; Majewski, J.

    2011-11-01

    This article discusses the Surface ProfilE Analysis Reflectometer (SPEAR), a vertical scattering geometry time-of-flight reflectometer, at the Los Alamos National Laboratory Lujan Neutron Scattering Center. SPEAR occupies flight path 9 and receives spallation neutrons from a polychromatic, pulsed (20Hz) source that pass through a liquid-hydrogen moderator at 20K coupled with a Be filter to shift their energy spectrum. The spallation neutrons are generated by bombarding a tungsten target with 800MeV protons obtained from an accelerator. The process produces an integrated neutron flux of ˜ 3.4×106 cm-2 s-1 at a proton current of 100 μA. SPEAR employs choppers and frame overlap mirrors to obtain a neutron wavelength range of 4.5-16 Å. SPEAR uses a single 200mm long 3He linear position-sensitive detector with ˜ 2 mm FWHM resolution for simultaneous studies of both specular and off-specular scattering. SPEAR's moderated neutrons are collimated into a beam which impinges from above upon a level sample with an average angle of 0.9° to the horizontal, to facilitate air-liquid interface studies. In the vertical direction, the beam converges at the sample position. The neutrons can be further collimated to the desired divergence by finely slitting the beam using a set of two 10B4C slit packages. The instrument is ideally suited to study organic and inorganic thin films with total thicknesses between 5 and 3000 Å in a variety of environments. Specifically designed sample chambers available at the instrument provide the opportunity to study biological systems at the solid-liquid interface. SPEAR's unique experimental capabilities are demonstrated by specific examples in this article. Finally, an outlook for SPEAR and perspectives on future instrumentation are discussed.

  9. Apparatus for Teaching Physics.

    ERIC Educational Resources Information Center

    Gottlieb, Herbert H., Ed.

    1982-01-01

    Discusses: (1) construction of an integrated spherical reflectometer; (2) limitations of the NOAA Weather Radio Network; and (3) a simple experiment to demonstrate/measure influence of damping force on amplitude resonance. Also discusses whether or not a homemade electrophorus can lose its charge and then recharge itself. (JN)

  10. A low cost, simple, portable instrument for the measurement of infra-red reflectance of paints

    NASA Astrophysics Data System (ADS)

    Marson, F.

    1982-05-01

    The construction and design of a low cost, simple, portable infra-red reflectometer which can be used to estimate the reflectance of paint films in the 800 nm region is described. The infra-red reflectances of a range of lustreless, semigloss and gloss olive drab camouflage paints determined using this instrument are compared to those obtained using modified commercial equipment and to the reflectances measured at 800 nm using a Cary model 17 spectrophotometer. The new reflectometer was shown to be superior to the modified commercial instrument currently specified in Australian government paint specifications and to be capable of estimating the reflectance of olive drab paints to within about one per cent of the Cary derived reflectance values. The reflectance values for a range of 24 experimental coatings made with pigments of varying absorption in the infra-red region are used to illustrate the effect of the instrument's spectral response and the necessity of establishing a reliable working standard.

  11. Assessment of the measurement performance of the in-vessel system of gap 6 of the ITER plasma position reflectometer using a finite-difference time-domain Maxwell full-wave code.

    PubMed

    da Silva, F; Heuraux, S; Ricardo, E; Quental, P; Ferreira, J

    2016-11-01

    We conducted a first assessment of the measurement performance of the in-vessel components at gap 6 of the ITER plasma position reflectometry with the aid of a synthetic Ordinary Mode (O-mode) broadband frequency-modulated continuous-wave reflectometer implemented with REFMUL, a 2D finite-difference time-domain full-wave Maxwell code. These simulations take into account the system location within the vacuum vessel as well as its access to the plasma. The plasma case considered is a baseline scenario from Fusion for Energy. We concluded that for the analyzed scenario, (i) the plasma curvature and non-equatorial position of the antenna have neglectable impact on the measurements; (ii) the cavity-like space surrounding the antenna can cause deflection and splitting of the probing beam; and (iii) multi-reflections on the blanket wall cause a substantial error preventing the system from operating within the required error margin.

  12. Detrimental Effect Elimination of Laser Frequency Instability in Brillouin Optical Time Domain Reflectometer by Using Self-Heterodyne Detection

    PubMed Central

    Li, Yongqian; Li, Xiaojuan; An, Qi; Zhang, Lixin

    2017-01-01

    A useful method for eliminating the detrimental effect of laser frequency instability on Brillouin signals by employing the self-heterodyne detection of Rayleigh and Brillouin scattering is presented. From the analysis of Brillouin scattering spectra from fibers with different lengths measured by heterodyne detection, the maximum usable pulse width immune to laser frequency instability is obtained to be about 4 µs in a self-heterodyne detection Brillouin optical time domain reflectometer (BOTDR) system using a broad-band laser with low frequency stability. Applying the self-heterodyne detection of Rayleigh and Brillouin scattering in BOTDR system, we successfully demonstrate that the detrimental effect of laser frequency instability on Brillouin signals can be eliminated effectively. Employing the broad-band laser modulated by a 130-ns wide pulse driven electro-optic modulator, the observed maximum errors in temperatures measured by the local heterodyne and self-heterodyne detection BOTDR systems are 7.9 °C and 1.2 °C, respectively. PMID:28335508

  13. Strain measurement using a Brillouin optical time domain reflectometer for development of aircraft structure health monitoring system

    NASA Astrophysics Data System (ADS)

    Shimizu, Takayuki; Yari, Takashi; Nagai, Kanehiro; Takeda, Nobuo

    2001-07-01

    We conducted theoretical and experimental approaches for applying Brillouin optical time domain reflectometer (BOTDR) to aircraft and spacecraft structure health monitoring system. Firstly, distributed strain was measured by BOTDR under 3-point bending test and a spatial resolution was enhanced up to 0.5m using Brillouin spectrum analysis and processing though the device used in this experiment had a spatial resolution of 2m normally. Secondly, dynamic strain measurement was executed under cyclic loading conditions. Brillouin spectrum measured under dynamic conditions is equivalent to superposed spectrum using many spectra measured under static loading conditions. As the measured spectrum was decomposed into many spectra in static loading state, the strain amplitude and its ratio could be estimated. Thirdly, strain and temperature could be measured independently using combined system of BOTDR and fiber Bragg grating (FBG) with wavelength division multiplexing (WDM). Additionally, the application of BOTDR sensing system was shown for a prototype carbon fiber reinforced plastic (CFRP) liquid hydrogen (LH2) tank under cryogenic condition.

  14. Implementation of the new multichannel X-mode edge density profile reflectometer for the ICRF antenna on ASDEX Upgrade

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Aguiam, D. E., E-mail: daguiam@ipfn.tecnico.ulisboa.pt; Silva, A.; Carvalho, P. J.

    A new multichannel frequency modulated continuous-wave reflectometry diagnostic has been successfully installed and commissioned on ASDEX Upgrade to measure the plasma edge electron density profile evolution in front of the Ion Cyclotron Range of Frequencies (ICRF) antenna. The design of the new three-strap ICRF antenna integrates ten pairs (sending and receiving) of microwave reflectometry antennas. The multichannel reflectometer can use three of these to measure the edge electron density profiles up to 2 × 10{sup 19} m{sup −3}, at different poloidal locations, allowing the direct study of the local plasma layers in front of the ICRF antenna. ICRF power coupling,more » operational effects, and poloidal variations of the plasma density profile can be consistently studied for the first time. In this work the diagnostic hardware architecture is described and the obtained density profile measurements were used to track outer radial plasma position and plasma shape.« less

  15. Technical overview of the millimeter-wave imaging reflectometer on the DIII-D tokamak (invited)

    DOE PAGES

    Muscatello, Christopher M.; Domier, Calvin W.; Hu, Xing; ...

    2014-07-22

    The two-dimensional mm-wave imaging reflectometer (MIR) on DIII-D is a multi-faceted device for diagnosing electron density fluctuations in fusion plasmas. Its multi-channel, multi-frequency capabilities and high sensitivity permit visualization and quantitative diagnosis of density perturbations, including correlation length, wavenumber, mode propagation velocity, and dispersion. The two-dimensional capabilities of MIR are made possible with twelve vertically separated sightlines and four-frequency operation (corresponding to four radial channels). The 48-channel DIII-D MIR system has a tunable source that can be stepped in 500 µs increments over a range of 56 to 74 GHz. An innovative optical design keeps both on-axis and off-axis channelsmore » focused at the cutoff surface, permitting imaging over an extended poloidal region. As a result, the integrity of the MIR optical design is confirmed by comparing Gaussian beam calculations to laboratory measurements of the transmitter beam pattern and receiver antenna patterns.« less

  16. Distributed phase birefringence measurements based on polarization correlation in phase-sensitive optical time-domain reflectometers.

    PubMed

    Soto, Marcelo A; Lu, Xin; Martins, Hugo F; Gonzalez-Herraez, Miguel; Thévenaz, Luc

    2015-09-21

    In this paper a technique to measure the distributed birefringence profile along optical fibers is proposed and experimentally validated. The method is based on the spectral correlation between two sets of orthogonally-polarized measurements acquired using a phase-sensitive optical time-domain reflectometer (ϕOTDR). The correlation between the two measured spectra gives a resonance (correlation) peak at a frequency detuning that is proportional to the local refractive index difference between the two orthogonal polarization axes of the fiber. In this way the method enables local phase birefringence measurements at any position along optical fibers, so that any longitudinal fluctuation can be precisely evaluated with metric spatial resolution. The method has been experimentally validated by measuring fibers with low and high birefringence, such as standard single-mode fibers as well as conventional polarization-maintaining fibers. The technique has potential applications in the characterization of optical fibers for telecommunications as well as in distributed optical fiber sensing.

  17. Millimeter-wave reflectometry for electron density profile and fluctuation measurements on NSTX

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kubota, S.; Nguyen, X. V.; Peebles, W. A.

    2001-01-01

    A millimeter-wave reflectometry system for electron density profile and fluctuation measurements is being developed and installed on the National Spherical Torus Experiment. The initial frequency coverage will be in the bands 12--18, 20--32, and 33--50 GHz, provided by frequency-tunable solid-state sources. These frequencies correspond to O-mode cutoff densities ranging from 1.8x10{sup 12} to 3.1x10{sup 13}cm{sup -3}, which will span both the plasma core ({rho}=r/a<0.8) and edge ({rho}>0.8) regions. Operated as a broadband swept-frequency (frequency-modulated continuous-wave) reflectometer, the diagnostic is expected to provide routine (shot-to-shot) time- ({<=}50 {mu}s) and spatially resolved ({approx}1 cm) density profiles. The previous hardware can be easilymore » reconfigured as a fixed-frequency reflectometer for density fluctuation measurements. The combination of measurements would be valuable for studying phenomena such as possible L- to H-mode transitions and edge-localized modes.« less

  18. Optical coherence domain reflectometry guidewire

    DOEpatents

    Colston, Billy W.; Everett, Matthew; Da Silva, Luiz B.; Matthews, Dennis

    2001-01-01

    A guidewire with optical sensing capabilities is based on a multiplexed optical coherence domain reflectometer (OCDR), which allows it to sense location, thickness, and structure of the arterial walls or other intra-cavity regions as it travels through the body during minimally invasive medical procedures. This information will be used both to direct the guidewire through the body by detecting vascular junctions and to evaluate the nearby tissue. The guidewire contains multiple optical fibers which couple light from the proximal to distal end. Light from the fibers at the distal end of the guidewire is directed onto interior cavity walls via small diameter optics such as gradient index lenses and mirrored corner cubes. Both forward viewing and side viewing fibers can be included. The light reflected or scattered from the cavity walls is then collected by the fibers, which are multiplexed at the proximal end to the sample arm of an optical low coherence reflectometer. The guidewire can also be used in nonmedical applications.

  19. High Resolution Millimeter Wave Detection of Vertical Cracks in the Space Shuttle External Tank Spray-On-Foam Insulation (SOFI)

    NASA Technical Reports Server (NTRS)

    Kharkovsky, S.; Zoughi, R.; Hepburn, F.

    2006-01-01

    Space Shuttle Columbia s catastrophic failure, the separation of a piece of spray-on-foam insulation (SOFI) from the external tank (ET) in the Space Shuttle Discovery s flight in 2005 and crack detected in its ET foam prior to its successful launch in 2006 emphasize the need for effective nondestructive methods for inspecting the shuttle ET SOFI. Millimeter wave nondestructive testing methods have been considered as potential and effective inspection tools for evaluating the integrity of the SOFI. This paper presents recent results of an investigation for the purpose of detecting vertical cracks in SOFI panels using a focused millimeter wave (150 GHz) reflectometer. The presented images of the SOFI panels show the capability of this reflectometer for detecting tight vertical cracks (also as a function of crack opening dimension) in exposed SOFI panels and while covered by a piece of SOFI ramp simulating a more realistic and challenging situation.

  20. Use of Time Domain Reflectometers (TDRs) in Permeable Pavement Systems to Predict Maintenance Needs and Effectiveness

    EPA Science Inventory

    As the surface in permeable pavement systems clogs, infiltration capacity decreases, so maintenance is required to maintain hydrologic performance. There is limited direct guidance for determining when maintenance is needed to prevent surface runoff bypass. Research is being co...

  1. Lunar Prospector: First Results and Lessons Learned

    NASA Astrophysics Data System (ADS)

    Scott Hubbard, G.; Feldman, William; Cox, Sylvia A.; Smith, Marcie A.; Chu-Thielbar, Lisa

    2002-01-01

    Lunar Prospector, the first competitively selected mission in NASA's Discovery Program, is conducting a one-year orbital survey of the Moon's composition and structure. Launched on January 6 1998, the suite of five instruments is measuring water/ice to a sensitivity of 50 ppm (hydrogen), detecting key elemental constituents, gas release events and mapping the Moon's gravitational and magnetic fields. The mission is described with emphasis on the first scientific results and lessons learned from managing a very low cost project. A mission overview and systems description is given along with final mission trajectories. Lessons learned from government-industry teaming, new modes of project management, and novel contractual arrangements are discussed. The suite of five instruments (neutron spectrometer, alpha particle spectrometer, gamma-ray spectrometer, electron reflectometer and magnetometer) is outlined with attention to final technical performance as well as development on a constrained budget and schedule. A review of our novel approaches to education and public outreach is discussed and a summary with suggestions and implications for future missions is provided.

  2. Use of Water Content Reflectometers in Bioinfiltration/Bioretention to Measure Water Movement and Estimate Evapotranspiration - abstract

    EPA Science Inventory

    Most bioinfiltration/bioretention models assume runoff is evenly distributed across the surface area and after the engineered fill media is no longer saturated, the volumetric water content (VWC) is constant throughout the media profile and at field capacity. Four to nine water ...

  3. Use of Water Content Reflectometers in Bioinfiltration/Bioretention to Measure Water Movement and Estimate Evapotranspiration

    EPA Science Inventory

    Most bioinfiltration/bioretention models assume runoff is evenly distributed across the surface area and after the engineered fill media is no longer saturated, the volumetric water content (VWC) is constant throughout the media profile and at field capacity. Four to nine water ...

  4. BioRef: A versatile time-of-flight reflectometer for soft matter applications at Helmholtz-Zentrum Berlin

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Strobl, M.; Kreuzer, M.; Helmholtz-Zentrum Berlin, Hahn-Meitner-Platz 1, 14109 Berlin

    2011-05-15

    BioRef is a versatile novel time-of-flight reflectometer featuring a sample environment for in situ infrared spectroscopy at the reactor neutron source BER II of the Helmholtz Zentrum Berlin fuer Materialien und Energie (HZB). After two years of design and construction phase the instrument has recently undergone commissioning and is now available for specular and off-specular neutron reflectivity measurements. BioRef is especially dedicated to the investigation of soft matter systems and studies at the solid-liquid interface. Due to flexible resolution modes and variable addressable wavelength bands that allow for focusing onto a selected scattering vector range, BioRef enables a broad rangemore » of surface and interface investigations and even kinetic studies with subsecond time resolution. The instrumental settings can be tailored to the specific requirements of a wide range of applications. The performance is demonstrated by several reference measurements, and the unique option of in situ on-board infrared spectroscopy is illustrated by the example of a phase transition study in a lipid multilayer film.« less

  5. Dependence of the Brillouin gain spectrum on linear strain distribution for optical time-domain reflectometer-type strain sensors

    NASA Astrophysics Data System (ADS)

    Naruse, Hiroshi; Tateda, Mitsuhiro; Ohno, Hiroshige; Shimada, Akiyoshi

    2002-12-01

    We theoretically derive the shape of the Brillouin gain spectrum, that is, the Brillouin backscattered-light power spectrum, produced in an optical fiber under conditions of a strain distribution that changes linearly with a constant slope. The modeled measurement system is an optical time-domain reflectometer-type strain sensor system. The linear strain distribution is one of the fundamental distributions and is produced in, for example, a beam to which a concentrated load is applied. By analyzing a function that expresses the shape of the derived Brillouin gain spectrum, we show that the strain calculated from the frequency at which the spectrum has a peak value coincides with that at the center of the effective pulsed light. In addition, the peak value and the full width at half-maximum of the Brillouin gain spectrum are both influenced by the strain difference between the two ends of the effective pulse. We investigate this influence in detail and obtain the relationship between strain difference and strain measurement error.

  6. Double peak-induced distance error in short-time-Fourier-transform-Brillouin optical time domain reflectometers event detection and the recovery method.

    PubMed

    Yu, Yifei; Luo, Linqing; Li, Bo; Guo, Linfeng; Yan, Jize; Soga, Kenichi

    2015-10-01

    The measured distance error caused by double peaks in the BOTDRs (Brillouin optical time domain reflectometers) system is a kind of Brillouin scattering spectrum (BSS) deformation, discussed and simulated for the first time in the paper, to the best of the authors' knowledge. Double peak, as a kind of Brillouin spectrum deformation, is important in the enhancement of spatial resolution, measurement accuracy, and crack detection. Due to the variances of the peak powers of the BSS along the fiber, the measured starting point of a step-shape frequency transition region is shifted and results in distance errors. Zero-padded short-time-Fourier-transform (STFT) can restore the transition-induced double peaks in the asymmetric and deformed BSS, thus offering more accurate and quicker measurements than the conventional Lorentz-fitting method. The recovering method based on the double-peak detection and corresponding BSS deformation can be applied to calculate the real starting point, which can improve the distance accuracy of the STFT-based BOTDR system.

  7. Scrape-off layer reflectometer for Alcator C-Mod.

    PubMed

    Lau, Cornwall; Hanson, Greg; Wilgen, John; Lin, Yijun; Wukitch, Steve

    2010-10-01

    A swept-frequency X-mode reflectometer is being built for Alcator C-Mod to measure the scrape-off layer density profiles at the top, middle, and bottom locations in front of both the new lower hybrid launcher and the new ion cyclotron range of frequencies antenna. The system is planned to operate between 100 and 146 GHz at sweep rates from 10 μs to 1 ms, and will cover a density range of approximately 10(16)-10(20) m(-3) at B(0)=5-5.4 T. To minimize the effects of density fluctuations, both differential phase and full phase reflectometry will be employed. Design, test data, and calibration results of this electronics system will be discussed. To reduce attenuation losses, tallguide (TE(01)) will be used for most of the transmission line system. Simulations of high mode conversion in tallguide components, such as e-plane hyperbolic secant radius of curvature bends, tapers, and horn antennas will be shown. Experimental measurements of the total attenuation losses of these components in the lower hybrid waveguide run will also be presented.

  8. Complex EUV imaging reflectometry: spatially resolved 3D composition determination and dopant profiling with a tabletop 13nm source

    NASA Astrophysics Data System (ADS)

    Porter, Christina L.; Tanksalvala, Michael; Gerrity, Michael; Miley, Galen P.; Esashi, Yuka; Horiguchi, Naoto; Zhang, Xiaoshi; Bevis, Charles S.; Karl, Robert; Johnsen, Peter; Adams, Daniel E.; Kapteyn, Henry C.; Murnane, Margaret M.

    2018-03-01

    With increasingly 3D devices becoming the norm, there is a growing need in the semiconductor industry and in materials science for high spatial resolution, non-destructive metrology techniques capable of determining depth-dependent composition information on devices. We present a solution to this problem using ptychographic coherent diffractive imaging (CDI) implemented using a commercially available, tabletop 13 nm source. We present the design, simulations, and preliminary results from our new complex EUV imaging reflectometer, which uses coherent 13 nm light produced by tabletop high harmonic generation. This tool is capable of determining spatially-resolved composition vs. depth profiles for samples by recording ptychographic images at multiple incidence angles. By harnessing phase measurements, we can locally and nondestructively determine quantities such as device and thin film layer thicknesses, surface roughness, interface quality, and dopant concentration profiles. Using this advanced imaging reflectometer, we can quantitatively characterize materials-sciencerelevant and industry-relevant nanostructures for a wide variety of applications, spanning from defect and overlay metrology to the development and optimization of nano-enhanced thermoelectric or spintronic devices.

  9. Effects of low Earth orbit environment on the Long Duration Exposure Facility thermal control coatings

    NASA Technical Reports Server (NTRS)

    Sampair, Thomas R.; Berrios, William M.

    1992-01-01

    One of the benefits of the Long Duration Exposure Facility (LDEF) was the opportunity to study the before and after effects of low earth orbit space environment on the spacecraft thermal control coatings. Since the LDEF's thermal control was totally passive by design, the selection of the external surface absorptivity to emissivity ratio (alpha/epsilon) and the ability for the coating to retain the alpha/epsilon over time was an important consideration in the thermal design of the LDEF. The primary surface coating chosen for the LDEF structure was clear chromic anodized aluminum with an average design alpha/epsilon of 0.32/0.16. External surface absorptivity (alpha) and emissivity (epsilon) were measured on all intercostals, longerons, tray mounting flanges, thermal control panels, and a limited number of experiment surface coatings after the experiment trays were removed from the LDEF structure. All surface alpha/epsilon measurements were made using portable hand held infrared and solar spectrum reflectometers. The absorptivity measurements were taken with a Devices and Services SSR-ER version 5.0 solar spectra reflectometer which has a stated uncertainty of +/- 0.01, and all normal emissivity measurements were made using the Gier Dunkle DB-100 infrared reflectometer also with a stated uncertainty of +/- 0.01. Both instruments were calibrated in the laboratory by LaRC instrumentation personnel before being used in the field at KSC. A combined total of 733 measurements were taken on the anodized aluminum hardware which included the structure (intercostals, longerons, and center ring), earth and space end thermal control panels, and experiment tray mounting flanges. The facility thermal control coatings measured in this survey cover 33 percent of the total exposed LDEF surface area. To correlate low earth orbit environmental effects on the anodized coatings, measurements were taken in both exposed and unexposed surfaces and compared to quality assurance (QA) measurements taken on the new surfaces at the time of hardware fabrication in 1978. The results of investigation are presented.

  10. Water content measurement in forest soils and decayed wood using time domain reflectometry

    Treesearch

    Andrew Gray; Thomas Spies

    1995-01-01

    The use of time domain reflectometry to measure moisture content in forest soils and woody debris was evaluated. Calibrations were developed on undisturbed soil cores from four forest stands and on point samples from decayed logs. An algorithm for interpreting irregularly shaped traces generated by the reflectometer was also developed. Two different calibration...

  11. Soil Water Content Sensors as a Method of Measuring Ice Depth

    NASA Astrophysics Data System (ADS)

    Whitaker, E.; Reed, D. E.; Desai, A. R.

    2015-12-01

    Lake ice depth provides important information about local and regional climate change, weather patterns, and recreational safety, as well as impacting in situ ecology and carbon cycling. However, it is challenging to measure ice depth continuously from a remote location, as existing methods are too large, expensive, and/or time-intensive. Therefore, we present a novel application that reduces the size and cost issues by using soil water content reflectometer sensors. Analysis of sensors deployed in an environmental chamber using a scale model of a lake demonstrated their value as accurate measures of the change in ice depth over any time period, through measurement of the liquid-to-solid phase change. A robust correlation exists between volumetric water content in time as a function of environmental temperature. This relationship allows us to convert volumetric water content into ice depth. An array of these sensors will be placed in Lake Mendota, Madison, Wisconsin in winter 2015-2016, to create a temporally high-resolution ice depth record, which will be used for ecological or climatological studies while also being transmitted to the public to increase recreational safety.

  12. ALICE—An advanced reflectometer for static and dynamic experiments in magnetism at synchrotron radiation facilities

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Abrudan, R.; Helmholtz-Zentrum-Berlin for Materials and Energy, 12489 Berlin; Brüssing, F.

    2015-06-15

    We report on significant developments of a high vacuum reflectometer (diffractometer) and spectrometer for soft x-ray synchrotron experiments which allows conducting a wide range of static and dynamic experiments. Although the chamber named ALICE was designed for the analysis of magnetic hetero- and nanostructures via resonant magnetic x-ray scattering, the instrument is not limited to this technique. The versatility of the instrument was testified by a series of pilot experiments. Static measurements involve the possibility to use scattering and spectroscopy synchrotron based techniques (photon-in photon-out, photon-in electron-out, and coherent scattering). Dynamic experiments require either laser or magnetic field pulses tomore » excite the spin system followed by x-ray probe in the time domain from nano- to femtosecond delay times. In this temporal range, the demagnetization/remagnetization dynamics and magnetization precession in a number of magnetic materials (metals, alloys, and magnetic multilayers) can be probed in an element specific manner. We demonstrate here the capabilities of the system to host a variety of experiments, featuring ALICE as one of the most versatile and demanded instruments at the Helmholtz Center in Berlin-BESSY II synchrotron center in Berlin, Germany.« less

  13. An evaluation of the NASA/GSFC Barnes field spectral reflectometer model 14-758, using signal/noise as a measure of utility

    NASA Astrophysics Data System (ADS)

    Bell, R.; Labovitz, M. L.

    1982-07-01

    A Barnes field spectral reflectometer which collected information in 373 channels covering the region from 0.4 to 2.5 micrometers was assessed for signal utility. A band was judged unsatisfactory if the probability was 0.1 or greater than its signal to noise ratio was less than eight to one. For each of the bands the probability of a noisy observation was estimated under a binomial assumption from a set of field crop spectra covering an entire growing season. A 95% confidence interval was calculated about each estimate and bands whose lower confidence limits were greater than 0.1 were judged unacceptable. As a result, 283 channels were deemed statistically satisfactory. Excluded channels correspond to portions of the electromagnetic spectrum (EMS) where high atmospheric absorption and filter wheel overlap occur. In addition, the analyses uncovered intervals of unsatisfactory detection capability within the blue, red and far infrared regions of vegetation spectra. From the results of the analysis it was recommended that 90 channels monitored by the instrument under consideration be eliminated from future studies. These channels are tabulated and discussed.

  14. AMOR - the versatile reflectometer at SINQ

    NASA Astrophysics Data System (ADS)

    Clemens, D.; Gross, P.; Keller, P.; Schlumpf, N.; Könnecke, M.

    2000-03-01

    We report on a new facility for neutron reflectometry situated at the end position of a cold neutron guide at the Swiss Spallation Neutron Source SINQ. The instrument is a flexible apparatus, adaptable to the needs of the user's individual experiment. Principally designed to operate in the time-of-flight mode it is also capable to exploit the fact that SINQ is a continuous source because PSI's developments in the field of thin film multilayers are fruitfully applied. By means of multilayer monochromators it can be converted into a constant wavelength reflectometer. Polarized neutron reflectometry on AMOR takes advantage of remanent FeCo/Ti:N supermirrors and multilayers which can be operated in a way that no spin flippers are needed. The time and angular contributions to the resolution in momentum transfer are separately determinable in TOF mode. The total length of the instrument is adjustable in order to optimize resolution together with the illumination of the sample's surface. Large sample environments can be placed on the sample table that is actively isolated against vibrations. Single detectors and an EMBL 3He area detector can be chosen, alternatively. The instrument concept as well as parameters of its components are presented.

  15. A simple solution to systematic errors in density determination by X-ray reflectivity: The XRR-density evaluation (XRR-DE) method

    NASA Astrophysics Data System (ADS)

    Bergese, P.; Bontempi, E.; Depero, L. E.

    2006-10-01

    X-ray reflectivity (XRR) is a non-destructive, accurate and fast technique for evaluating film density. Indeed, sample-goniometer alignment is a critical experimental factor and the overriding error source in XRR density determination. With commercial single-wavelength X-ray reflectometers, alignment is difficult to control and strongly depends on the operator. In the present work, the contribution of misalignment on density evaluation error is discussed, and a novel procedure (named XRR-density evaluation or XRR-DE method) to minimize the problem will be presented. The method allows to overcome the alignment step through the extrapolation of the correct density value from appropriate non-specular XRR data sets. This procedure is operator independent and suitable for commercial single-wavelength X-ray reflectometers. To test the XRR-DE method, single crystals of TiO 2 and SrTiO 3 were used. In both cases the determined densities differed from the nominal ones less than 5.5%. Thus, the XRR-DE method can be successfully applied to evaluate the density of thin films for which only optical reflectivity is today used. The advantage is that this method can be considered thickness independent.

  16. Portable Chemical Agent Detection System: Differential Reflectometer and Light Scattering Approaches

    DTIC Science & Technology

    2005-02-15

    possible to conduct elemental analysis on modified capillaries because of the polymer coating. Instead, measurements of electroosmotic flow were used...design There are several essential requirements for a sensitive chemiluminescence cell (Figure 1); good reagent/analyte mixing for maximum photon yield...Cutaway of Chemiluminescence cell the cooled pint housing. In our design, the concentric inlets will increase photon collection due to better mixing of

  17. Refractive-index profiling of embedded microstructures in optical materials

    NASA Astrophysics Data System (ADS)

    Dave, Digant P.; Milner, Thomas E.

    2002-04-01

    We describe use of a phase-sensitive low-coherence reflectometer to measure spatial variation of refractive index in optical materials. The described interferometric technique is demonstrated to be a valuable tool to profile the refractive index of optical elements such as integrated waveguides and photowritten optical microstructures. As an example, a refractive-index profile is mapped of a microstructure written in a microscope glass slide with an ultrashort-pulse laser.

  18. OPTICAL FIBRES AND FIBREOPTIC SENSORS: Polarisation reflectometry of anisotropic optical fibres

    NASA Astrophysics Data System (ADS)

    Konstantinov, Yurii A.; Kryukov, Igor'I.; Pervadchuk, Vladimir P.; Toroshin, Andrei Yu

    2009-11-01

    Anisotropic, polarisation-maintaining fibres have been studied using a reflectometer and integrated optic polariser. Linearly polarised pulses were launched into the fibre under test at different angles between their plane of polarisation and the main optical axis of the fibre. A special procedure for the correlation analysis of these reflectograms is developed to enhance the reliability of the information about the longitudinal optical uniformity ofanisotropic fibres.

  19. Development of Long-Pulse Heating and Current Drive Actuators and Operational Techniques Compatible with a High-Z Divertor and First Wall

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, Guiding

    Accurate measurement of the edge electron density profile is essential to optimizing antenna coupling and assessment of impurity contamination in studying long-pulse plasma heating and current drive in fusion devices. Measurement of the edge density profile has been demonstrated on the US fusion devices such as C-Mod, DIII-D, and TFTR amongst many devices, and has been used for RF loading and impurity modeling calculations for many years. University of Science and Technology of China (USTC) has recently installed a density profile reflectometer system on the EAST fusion device at the Institute of Plasma Physics, Chinese Academy of Sciences in Chinamore » based on the University of California Los Angeles (UCLA)-designed reflectometer system on the DIII-D fusion device at General Atomics Company in San Diego, California. UCLA has been working with USTC to optimize the existing microwave antenna, waveguide system, microwave electronics, and data analysis to produce reliable edge density profiles. During the past budget year, progress has been made in all three major areas: effort to achieve reliable system operations under various EAST operational conditions, effort to optimize system performance, and effort to provide quality density profiles into EAST’s database routinely.« less

  20. Application of Time Domain Reflectometers in Urban Settings ...

    EPA Pesticide Factsheets

    Time domain reflectometers (TDRs) are sensors that measure the volumetric water content of soils and porous media. The sensors consist of stainless steel rods connected to a circuit board in an epoxy housing. An electromagnetic pulse is propagated along the rods. The time, or period, required for the signal to travel down the rods and back varies with the volumetric water content of the surrounding media and temperature. A calibration curve is needed for the specific media. TDRs were developed mostly for agricultural applications; however, the technology has also been applied to forestry and ecological research. This study demonstrates the use of TDRs for quantifying drainage properties in low impact development (LID) stormwater controls, specifically permeable pavement and rain garden systems. TDRs were successfully used to monitor the responses of urban fill, engineered bioretention media, and the aggregate storage layer under permeable pavement to multiple rain events of varying depth, intensity, and duration. The hydrologic performance of permeable pavement and rain garden systems has previously been quantified for underdrain systems, but there have been few studies of systems that drain to the underlying soils. We know of no published studies outlining the use of TDR technology to document drainage properties in media other than soil. In this study TDRs were installed at multiple locations and depths in underlying urban fill soils, engineered bior

  1. Prototype Development and Evaluation of Self-Cleaning Concentrated Solar Power Collectors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mazumder, Malay K.; Horenstein, Mark N.; Joglekar, Nitin R.

    The feasibility of integrating and retrofitting transparent electrodynamic screens (EDS) on the front surfaces of solar collectors was established as a means to provide active self-cleaning properties for parabolic trough and heliostat reflectors, solar panels, and Fresnel lenses. Prototype EDS-integrated solar collectors, including second-surface glass mirrors, metallized Acrylic-film mirrors, and dielectric mirrors, were produced and tested in environmental test chambers for removing the dust layer deposited on the front surface of the mirrors. The evaluation of the prototype EDS-integrated mirrors was conducted using dust and environmental conditions that simulate the field conditions of the Mojave Desert. Test results showed thatmore » the specular reflectivity of the mirrors could be maintained at over 90% over a wide range of dust loadings ranging from 0 to 10 g/m 2, with particle diameter varying from 1 to 50 μm. The measurement of specular reflectivity (SR) was performed using a D&S Reflectometer at wavelength 660 nm. A non-contact reflectometer was designed and constructed for rapid measurement of specular reflectivity at the same wavelength. The use of this new noncontact instrument allowed us to measure SR before and after EDS activation. Several EDS prototypes were constructed and evaluated with different electrode configurations, electrode materials, and encapsulating dielectric materials.« less

  2. In situ polarized 3He system for the Magnetism Reflectometer at the Spallation Neutron Source.

    PubMed

    Tong, X; Jiang, C Y; Lauter, V; Ambaye, H; Brown, D; Crow, L; Gentile, T R; Goyette, R; Lee, W T; Parizzi, A; Robertson, J L

    2012-07-01

    We report on the in situ polarized (3)He neutron polarization analyzer developed for the time-of-flight Magnetism Reflectometer at the Spallation Neutron Source at Oak Ridge National Laboratory. Using the spin exchange optical pumping method, we achieved a (3)He polarization of 76% ± 1% and maintained it for the entire three-day duration of the test experiment. Based on transmission measurements with unpolarized neutrons, we show that the average analyzing efficiency of the (3)He system is 98% for the neutron wavelength band of 2-5 Å. Using a highly polarized incident neutron beam produced by a supermirror bender polarizer, we obtained a flipping ratio of >100 with a transmission of 25% for polarized neutrons, averaged over the wavelength band of 2-5 Å. After the cell was depolarized for transmission measurements, it was reproducibly polarized and this performance was maintained for three weeks. A high quality polarization analysis experiment was performed on a reference sample of Fe/Cr multilayer with strong spin-flip off-specular scattering. Using a combination of the position sensitive detector, time-of-flight method, and the excellent parameters of the (3)He cell, the polarization analysis of the two-dimensional maps of reflected, refracted, and off-specular scattered intensity above and below the horizon were obtained, simultaneously.

  3. Vitamin D Levels and Related Genetic Polymorphisms, Sun Exposure, Skin Color, and Risk of Aggressive Prostate Cancer

    DTIC Science & Technology

    2011-07-01

    sun exposure, and dietary calcium and vitamin D intake are ascertained. Finally, the melanin content of the skin is measured using a skin reflectance...meter called a Dermaspectrometer, to measure baseline skin melanin content, which is known to inhibit vitamin D synthesis from sunlight. This...three hospitals in Chicago, along with demographic and medical information, BMI, and skin melanin content using a portable narrow-band reflectometer

  4. Note: 4-bounce neutron polarizer for reflectometry applications

    NASA Astrophysics Data System (ADS)

    Nagy, B.; Merkel, D. G.; Jakab, L.; Füzi, J.; Veres, T.; Bottyán, L.

    2018-05-01

    A neutron polarizer using four successive reflections on m = 2.5 supermirrors was built and installed at the GINA neutron reflectometer at the Budapest Neutron Centre. This simple setup exhibits 99.6% polarizing efficiency with 80% transmitted intensity of the selected polarization state. Due to the geometry, the higher harmonics in the incident beam are filtered out, while the optical axis of the beam remains intact for easy mounting and dismounting the device in an existing experimental setup.

  5. Characterization and Measurements from the Infrared Grazing Angle Reflectometer

    DTIC Science & Technology

    2012-06-14

    18 3. List of sample scatter pattern fitting values. All values were taken from Ngan’s paper ”Experimental Analysis of BRDF Models - Supplemental” [1...using a BRDF model , and the absorptance can be modeled using a Fresnel absorptance. After defining both of these values, we can calculate the power seen... BRDF model of the face of the detector. This paper will examine the case of a flat detector with some index of refraction n. This air-detector

  6. Airborne Observation of Ocean Surface Roughness Variations Using a Combination of Microwave Radiometer and Reflectometer Systems: The Second Virginia Offshore (Virgo II) Experiment

    DTIC Science & Technology

    2014-03-06

    from scattered satellite transmissions, was first demonstrated using Global Navigation Satellite System ( GNSS ) reflections. Recently, reflectometry has...Earth’s atmosphere. The 2012 GNSS +R workshop provided an opportunity for engineers and Earth scientists to assess the state of the art, demonstrate new...bi-static radar technique utilizes signals of opportunity transmitted from existing L-band Global Navigation Satellite Systems ( GNSS ), including GPS

  7. Assessment of surface roughness by use of soft x-ray scattering

    NASA Astrophysics Data System (ADS)

    Meng, Yan-li; Wang, Yong-gang; Chen, Shu-yan; Chen, Bo

    2009-08-01

    A soft x-ray reflectometer with laser produced plasma source has been designed, which can work from wavelength 8nm to 30 nm and has high performance. Using the soft x-ray reflectometer above, the scattering light distribution of silicon and zerodur mirrors which have super-smooth surfaces could be measured at different incidence angle and different wavelength. The measurement when the incidence angle is 2 degree and the wavelength is 11nm has been given in this paper. A surface scattering theory of soft x-ray grazing incidence optics based on linear system theory and an inverse scattering mathematical model is introduced. The vector scattering theory of soft x-ray scattering also is stated in detail. The scattering data are analyzed by both the methods above respectively to give information about the surface profiles. On the other hand, both the two samples are measured by WYKO surface profiler, and the surface roughness of the silicon and zerodur mirror is 1.3 nm and 1.5nm respectively. The calculated results are in quantitative agreement with those measured by WYKO surface profiler, which indicates that soft x-ray scattering is a very useful tool for the evaluation of highly polished surfaces. But there still some difference among the results of different theory and WYKO, and the possible reasons of such difference have been discussed in detail.

  8. The Southwest Research Institute ultraviolet reflectance chamber (SwURC): a far ultraviolet reflectometer

    NASA Astrophysics Data System (ADS)

    Winters, Gregory S.; Retherford, Kurt D.; Davis, Michael W.; Escobedo, Stephen M.; Bassett, Eric C.; Patrick, Edward L.; Nagengast, Maggie E.; Fairbanks, Matthew H.; Miles, Paul F.; Parker, Joel W.; Gladstone, G. Randall; Slater, David C.; Stern, S. Alan

    2012-10-01

    We designed and assembled a highly capable UV reflectometer chamber and data acquisition system to provide bidirectional scattering data of various surfaces and materials. This chamber was initially conceived to create laboratory-based UV reflectance measurements of water frost on lunar soil/regolith simulants, to support interpretation of UV reflectance data from the Lyman Alpha Mapping Project ("LAMP") instrument on-board the NASA Lunar Reconnaissance Orbiter spacecraft. A deuterium lamp illuminates surfaces and materials at a fixed 45° incident beam angle over the 115 to 200 nm range via a monochromator, while a photomultiplier tube detector is scanned to cover emission angles -85° to +85° (with a gap from -60° to -30°, due to the detector blocking the incident beam). Liquid nitrogen cools the material/sample mount when desired. The chamber can be configured to test a wide range of samples and materials using sample trays and holders. Test surfaces to date include aluminum mirrors, water ice, reflectance standards, and frozen mixtures of water and lunar soil/regolith stimulant. Future UV measurements planned include Apollo lunar samples, meteorite samples, other ices, minerals, and optical surfaces. Since this chamber may well be able to provide useful research data for groups outside Southwest Research Institute, we plan to take requests from and collaborate with others in the UV and surface reflection research community.

  9. Production and Performance of the InFOCmicronS 20-40 keV Graded Multilayer Mirror

    NASA Technical Reports Server (NTRS)

    Berendse, F.; Owens, S. M.; Serlemitsos, P. J.; Tueller, J.; Chan, K.-W.; Soong, Y.; Krimm, H.; Baumgartner, W. H.; Tamura, K.; Okajima, T.; hide

    2002-01-01

    The International Focusing Optics Collaboration for micron Crab Sensitivity (InFOC micronS) balloon-borne hard x-ray incorporates graded multilayer technology to obtain significant effective area at energies previously inaccessible to x-ray optics. The telescope mirror consists of 2040 segmented thin aluminum foils coated with replicated Pt/C multilayers. A sample of these foils was scanned using a pencil-beam reflectometer to determine, multilayer quality. The results of the reflectometer measurements demonstrate our capability to produce large quantity of foils while maintaining high-quality multilayers with a mean Nevot-Croce interface roughness of 0.5nm. We characterize the performance of the complete InFOC micronS telescope with a pencil beam raster scan to determine the effective area and encircled energy function of the telescope. The effective area of the complete telescope is 78, 42 and 22 square centimeters at 20 30 and 40 keV. respectively. The measured encircled energy fraction of the mirror has a half-power diameter of 2.0 plus or minus 0.5 arcmin (90% confidence). The mirror successfully obtained an image of the accreting black hole Cygnus X-1 during a balloon flight in July, 2001. The successful completion and flight test of this telescope demonstrates that graded-multilayer telescopes can be manufactured with high reliability for future x-ray telescope missions such as Constellation-X.

  10. AMOR - the time-of-flight neutron reflectometer at SINQ/PSI

    NASA Astrophysics Data System (ADS)

    Gupta, Mukul; Gutberlet, T.; Stahn, J.; Keller, P.; Clemens, D.

    2004-07-01

    The apparatus for multioptional reflectometry (AMOR) at SINQ/PSI is a versatile reflectometer operational in the time-of-flight (TOF) mode (in a wavelength range of 0.15 nm <λ < 1.3 nm) as well as in the monochromatic (theta-2theta) mode with both polarized and unpolarized neutrons. AMOR is designed to perform reflectometry measurements in horizontal sample-plane geometry which allows studying both solid-liquid and liquid-liquid interfaces. A pulsed cold neutron beam from the end position of the neutron guide is produced by a dual-chopper system (side-by-side) having two windows at 180^{circ} and rotatable with a maximum frequency of 200 Hz. In the TOF mode, the chopper frequency, width of the gating window and the chopper-detector distance can be selected independently providing a wide range of q-resolution (Delta q/q=1-10&%slash;). Remanent FeCoV/Ti : N supermirrors are used as polarizer/analyzer with a polarization efficiency of sim97&%slash;. For the monochromatic wavelength mode, a Ni/Ti multilayer is used as a monochromator, giving sim50&%slash; reflectivity at a wavelength of 0.47 nm. In the present work, a detailed description of the instrument and setting-up of the polarization option is described. Results from some of the recent studies with polarized neutrons and measurements on liquid surfaces are presented.

  11. Upgrades to the Polarized Neutron Reflectometer Asterix at LANSCE

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pynn, Roger

    2015-03-16

    We have upgraded the polarized neutron reflectometer, Asterix, at the Lujan Neutron Scattering Center at Los Alamos for the benefit of the research communities that study magnetic and complex-fluid films, both of which play important roles in support of the DOE’s energy mission. The upgrades to the instrument include: • A secondary spectrometer that was integrated with a Huber sample goniometer purchased with other funds just prior to the start of our project. The secondary spectrometer provides a flexible length for the scattered flight path, includes a mechanism to select among 3 alternative polarization analyzers as well as a supportmore » for new neutron detectors. Also included is an optic rail for reproducible positioning of components for Spin Echo Scattering Angle Measurement (SESAME). The entire secondary spectrometer is now non-magnetic, as required for neutron Larmor labeling. • A broad-band neutron polarizer for the incident neutron beam based on the V geometry. • A wide-angle neutron polarization analyzer • A 2d position-sensitive neutron detector • Electromagnetic coils (Wollaston prisms) for SESAME plus the associated power supplies, cooling, safety systems and integration into the data acquisition system. The upgrades allowed a nearly effortless transition between configurations required to serve the polarized neutron reflectometry community, users of the 11 T cryomagnet and users of SESAME.« less

  12. Effects of ICRF power on SOL density profiles and LH coupling during simultaneous LH and ICRF operation on Alcator C-Mod

    NASA Astrophysics Data System (ADS)

    Lau, C.; Lin, Y.; Wallace, G.; Wukitch, S. J.; Hanson, G. R.; Labombard, B.; Ochoukov, R.; Shiraiwa, S.; Terry, J.

    2013-09-01

    A dedicated experiment during simultaneous lower hybrid (LH) and ion cyclotron range-of-frequencies (ICRF) operations is carried out to evaluate and understand the effects of ICRF power on the scrape-off-layer (SOL) density profiles and on the resultant LH coupling for a wide range of plasma parameters on Alcator C-Mod. Operation of the LH launcher with the adjacent ICRF antenna significantly degrades LH coupling while operation with the ICRF antenna that is not magnetically connected to the LH launcher minimally affects LH coupling. An X-mode reflectometer system at three poloidal locations adjacent to the LH launcher and a visible video camera imaging the LH launcher are used to measure local SOL density profile and emissivity modifications with the application of LH and LH + ICRF power. These measurements confirm that the density in front of the LH launcher depends strongly on the magnetic field line mapping of the active ICRF antenna. Reflectometer measurements also observe both ICRF-driven and LH-driven poloidal density profile asymmetries, especially a strong density depletion at certain poloidal locations in front of the LH launcher during operation with a magnetically connected ICRF antenna. The results indicate that understanding both LH-driven flows and ICRF sheath driven flows may be necessary to understand the observed density profile modifications and LH coupling results during simultaneous LH + ICRF operation.

  13. Compact Instruments Measure Heat Potential

    NASA Technical Reports Server (NTRS)

    2009-01-01

    Based in Huntsville, Alabama, AZ Technology Inc. is a woman- and veteran-owned business that offers expertise in electromechanical-optical design and advanced coatings. AZ Technology has received eight Small Business Innovation Research (SBIR) contracts with Marshall Space Flight Center for the development of spectral reflectometers and the measurement of surface thermal properties. The company uses a variety of measurement services and instruments, including the Spectrafire, a portable spectral emissometer it used to assist General Electric with the design of its award-winning Giraffe Warmer for neonatal intensive care units.

  14. A Review of Methods for Sensing the Nitrogen Status in Plants: Advantages, Disadvantages and Recent Advances

    PubMed Central

    Muñoz-Huerta, Rafael F.; Guevara-Gonzalez, Ramon G.; Contreras-Medina, Luis M.; Torres-Pacheco, Irineo; Prado-Olivarez, Juan; Ocampo-Velazquez, Rosalia V.

    2013-01-01

    Nitrogen (N) plays a key role in the plant life cycle. It is the main plant mineral nutrient needed for chlorophyll production and other plant cell components (proteins, nucleic acids, amino acids). Crop yield is affected by plant N status. Thus, the optimization of nitrogen fertilization has become the object of intense research due to its environmental and economic impact. This article focuses on reviewing current methods and techniques used to determine plant N status. Kjeldahl digestion and Dumas combustion have been used as reference methods for N determination in plants, but they are destructive and time consuming. By using spectroradiometers, reflectometers, imagery from satellite sensors and digital cameras, optical properties have been measured to estimate N in plants, such as crop canopy reflectance, leaf transmittance, chlorophyll and polyphenol fluorescence. High correlation has been found between optical parameters and plant N status, and those techniques are not destructive. However, some drawbacks include chlorophyll saturation, atmospheric and soil interference, and the high cost of instruments. Electrical properties of plant tissue have been used to estimate quality in fruits, and water content in plants, as well as nutrient deficiency, which suggests that they have potential for use in plant N determination. PMID:23959242

  15. High speed reflectometer for EUV mask-blanks

    NASA Astrophysics Data System (ADS)

    Wies, Christian; Lebert, Rainer; Jagle, Bernhard; Juschkin, L.; Sobel, F.; Seitz, H.; Walter, Ronny; Laubis, C.; Scholze, F.; Biel, W.; Steffens, O.

    2005-06-01

    AIXUV GmbH and partners have developed a high speed Reflectometer for EUV mask-blanks which is fully compliant with the SEMI-standard P38 for EUV-mask-blank metrology. The system has been installed in June 2004 at SCHOTT Lithotec AG. It features high throughput, high lateral and spectral resolution, high reproducibility and low absolute uncertainty. Using AIXUV's EUV-LAMP and debris mitigation, low cost-of-ownership and high availability is expected. The spectral reflectance of up to 3 mask-blanks per hour can be measured with at least 20 spots each. The system is push button-controlled. Results are stored in CSV file format. For a spot size of 0.1x1 mm2, 2000 spectral channels of 1.6 pm bandwidth are recorded from 11.6 nm to 14.8 nm. The reflectance measurement is based on the comparison of the sample under test to two reference mirrors calibrated at the PTB radiometry laboratory at BESSY II. The three reflection spectra are recorded simultaneously. For each spot more than 107 photons are accumulated in about 20 s, providing statistical reproducibility below 0.2% RMS. The total uncertainty is below 0.5% absolute. Wavelength calibration better than 1 pm RMS over the whole spectral range is achieved by reference to NIST published wavelengths of about 100 xenon emission lines. It is consistent with the wavelength of the krypton 3d-5p absorption resonance at 13.5947 nm to better than 2 pm.

  16. High speed reflectometer for EUV mask-blanks

    NASA Astrophysics Data System (ADS)

    Wies, C.; Lebert, R.; Jaegle, B.; Juschkin, L.; Sobel, F.; Seitz, H.; Walter, R.; Laubis, C.; Scholze, F.; Biel, W.; Steffens, O.

    2005-05-01

    AIXUV GmbH and partners have developed a high speed Reflectometer for EUV mask-blanks which is fully compliant with the SEMI-standard P38 for EUV-mask-blank metrology. The system has been installed in June 2004 at SCHOTT Lithotec AG. It features high throughput, high lateral and spectral resolution, high reproduci-bility and low absolute uncertainty. Using AIXUV's EUV-LAMP and debris mitigation, low cost-of-ownership and high availability is expected. The spectral reflectance of up to 3 mask-blanks per hour can be measured with at least 20 spots each. The system is push button-controlled. Results are stored in CSV file format. For a spot size of 0.1×1 mm2, 2000 spectral chan-nels of 1.6 pm bandwidth are recorded from 11.6 nm to 14.8 nm. The reflectance measurement is based on the comparison of the sample under test to two reference mirrors calibrated at the PTB radiometry laboratory at BESSY II. The three reflection spectra are recorded simultaneously. For each spot more than 107 photons are ac-cumulated in about 20 s, providing statistical reproducibility below 0.2 % RMS. The total uncertainty is below 0.5 % absolute. Wavelength calibration better than 1 pm RMS over the whole spectral range is achieved by refe-rence to NIST published wavelengths of about 100 xenon emission lines. It is consistent with the wavelength of the krypton 3d-5p absorption resonance at 13.5947 nm to better than 2 pm.

  17. Longitudinal measurement of chromatic dispersion along an optical fiber transmission system with a new correction factor

    NASA Astrophysics Data System (ADS)

    Abbasi, Madiha; Imran Baig, Mirza; Shafique Shaikh, Muhammad

    2013-12-01

    At present existence OTDR based techniques have become a standard practice for measuring chromatic dispersion distribution along an optical fiber transmission link. A constructive measurement technique has been offered in this paper, in which a four wavelength bidirectional optical time domain reflectometer (OTDR) has been used to compute the chromatic dispersion allocation beside an optical fiber transmission system. To improve the correction factor a novel formulation has been developed, which leads to an enhanced and defined measurement. The investigational outcomes obtained are in good harmony.

  18. Real-time investigation of protein unfolding at an air–water interface at the 1 s time scale

    PubMed Central

    Yano, Yohko F.; Arakawa, Etsuo; Voegeli, Wolfgang; Matsushita, Tadashi

    2013-01-01

    Protein unfolding at an air–water interface has been demonstrated such that the X-ray reflectivity can be measured with an acquisition time of 1 s using a recently developed simultaneous multiple-angle–wavelength-dispersive X-ray reflectometer. This has enabled the electron density profile of the adsorbed protein molecules to be obtained in real time. A globular protein, lysozyme, adsorbed at the air–water interface is found to unfold into a flat shape within 1 s. PMID:24121352

  19. Analysis of a novel sensor interrogation technique based on fiber cavity ring-down (CRD) loop and OTDR

    NASA Astrophysics Data System (ADS)

    Yüksel, Kivilcim; Yilmaz, Anil

    2018-07-01

    We present the analysis of a remote sensor based on fiber Cavity Ring-Down (CRD) loop interrogated by an Optical Time Domain Reflectometer (OTDR) taking into account both practical limitations and the related signal processing. A commercial OTDR is used for both pulse generation and sensor output detection. This allows obtaining a compact and simple design for intensity-based sensor applications. This novel sensor interrogation approach is experimentally demonstrated by placing a variable attenuator inside the fiber loop that mimics a sensor head.

  20. Fiber optic security seal including plural Bragg gratings

    DOEpatents

    Forman, Peter R.

    1994-01-01

    An optical security system enables the integrity of a container seal to be remotely interrogated. A plurality of Bragg gratings is written holographically into the core of at least one optical fiber placed about the container seal, where each Bragg grating has a predetermined location and a known frequency for reflecting incident light. A time domain reflectometer is provided with a variable frequency light output that corresponds to the reflecting frequencies of the Bragg gratings to output a signal that is functionally related to the location and reflecting frequency of each of the Bragg gratings.

  1. Applications Of Measurement Techniques To Develop Small-Diameter, Undersea Fiber Optic Cables

    NASA Astrophysics Data System (ADS)

    Kamikawa, Neil T.; Nakagawa, Arthur T.

    1984-12-01

    Attenuation, strain, and optical time domain reflectometer (OTDR) measurement techniques were applied successfully in the development of a minimum-diameter, electro-optic sea floor cable. Temperature and pressure models for excess attenuation in polymer coated, graded-index fibers were investigated analytically and experimentally using these techniques in the laboratory. The results were used to select a suitable fiber for the cable. Measurements also were performed on these cables during predeployment and sea-trial testing to verify laboratory results. Application of the measurement techniques and results are summarized in this paper.

  2. High-resolution reflectometer for monitoring of biological samples

    NASA Astrophysics Data System (ADS)

    Men, Liqiu; Lu, Ping; Chen, Qiying

    2008-06-01

    High-resolution optical low-coherence reflectometry is applied to monitor biological samples. It has been found that the reflectivity of aged cow's milk is significantly lower than that of the fresh milk with a difference of 5.35dB. During the process of heating the fresh milk at a constant temperature of 80°C, the reflectivity of the milk gradually decreases with the increase of the heating duration. The technique is proved to be effective in monitoring the change in the refractive index of the sample.

  3. First tests of a MIEZE (modulated intensity by Zero effort)-type instrument on a pulsed neutron source

    NASA Astrophysics Data System (ADS)

    Bleuel, M.; Bröll, M.; Lang, E.; Littrell, K.; Gähler, R.; Lal, J.

    2006-01-01

    In this paper we report the results of our first tests of a novel proof-of-principle instrument developed at the IPNS, Argonne. The experiment was performed on the time of flight POSY1 instrument, the polarized reflectometer at the IPNS, which was modified to accommodate the apparatus. Two sets of RF-flippers were tested together, generating a modulated intensity by zero effort (MIEZE)-type neutron resonant spin echo signal which was observed at the detector using a wide neutron wavelength band.

  4. Dating Violence among College Students: Key Issues for College Counselors

    ERIC Educational Resources Information Center

    Murray, Christine E.; Kardatzke, Kerrie N.

    2007-01-01

    The authors present a review of literature examining dating violence among college students. They describe 6 key issues related to dating violence among college students that affect college counselors' work. These key issues relate to the incidence and prevalence of physical, sexual, and psychological violence in college students' dating…

  5. Report of the key-comparison of spectral diffuse reflectance (EURAMET.PR-K5) (Ref. 619)

    NASA Astrophysics Data System (ADS)

    Andor, György; Gál, Péter

    2018-01-01

    This report details the final results of the EURAMET comparison on regular spectral transmittance carried out between 2006 and 2016. The aim of this comparison was to check the agreement of measurement of the spectral diffuse reflectance among participants, using the measurement geometry of d/0 or 0/d in the wavelength range of 360 nm to 780 nm at 20 nm increment. We used a star type comparison: first the participants sent their samples to the pilot, than the pilot measured all the samples of the participants and sent them back. The participants measured the samples and sent them to the pilot for control measurement. Six standards were used as reference standards in order to maintain the scale during the comparison. These were three samples of BCR-406 opal glasses (BCR 30506; BCR 30303; BCR 30704), an MC20 Russian opal glass (MC 4777) and two samples made of pressed halon (polytetrafluoroethylene) powder (halon 2007A; halon 2007C). These six samples were designated as the Comparison reference standards. The diffuse reflectance was initially measured on the OMH (BFKH) absolute reflectometer. The link to the CCPR-K5 results was BFKH, and the check on BFKH was the PTB results who also participated in the CCPR-K5 comparison. The participants were GUM, INM, LNE, METAS, BFKH, PTB, SP. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCPR, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  6. Evaluation of low-frequency operational limit of proposed ITER low-field-side reflectometer waveguide run including miter bends.

    PubMed

    Wang, G; Peebles, W A; Doyle, E J; Crocker, N A; Wannberg, C; Lau, C; Hanson, G R; Doane, J L

    2017-10-01

    The present design concept for the ITER low-field-side reflectometer transmission line (TL) consists of an ∼40 m long, 6.35 cm diameter helically corrugated waveguide (WG) together with ten 90° miter bends. This paper presents an evaluation of the TL performance at low frequencies (33-50 GHz) where the predicted HE 11 mode ohmic and mode conversion losses start to increase significantly. Quasi-optical techniques were used to form a near Gaussian beam to efficiently couple radiation in this frequency range into the WG. It was observed that the output beams from the guide remained linearly polarized with cross-polarization power levels of ∼1.5%-3%. The polarization rotation due to the helical corrugations was in the range ∼1°-3°. The radiated beam power profiles typically show excellent Gaussian propagation characteristics at distances >20 cm from the final exit aperture. The round trip propagation loss was found to be ∼2.5 dB at 50 GHz and ∼6.5 dB at 35 GHz, showing an inverse increase with frequency. This was consistent with updated calculations of miter bend and ohmic losses. At low frequencies (33-50 GHz), the mode purity remained very good at the exit of the waveguide, and the losses are perfectly acceptable for operation in ITER. The primary challenge may come from the future addition of a Gaussian telescope and other filter components within the corrugated guide, which will likely introduce additional perturbations to the beam profile and an increase in mode-conversion loss.

  7. Bubble velocity, diameter, and void fraction measurements in a multiphase flow using fiber optic reflectometer

    NASA Astrophysics Data System (ADS)

    Lim, Ho-Joon; Chang, Kuang-An; Su, Chin B.; Chen, Chi-Yueh

    2008-12-01

    A fiber optic reflectometer (FOR) technique featuring a single fiber probe is investigated for its feasibility of measuring the bubble velocity, diameter, and void fraction in a multiphase flow. The method is based on the interference of the scattered signal from the bubble surface with the Fresnel reflection signal from the tip of the optical fiber. Void fraction is obtained with a high accuracy if an appropriate correction is applied to compensate the underestimated measurement value. Velocity information is accurately obtained from the reflected signals before the fiber tip touches the bubble surface so that several factors affecting the traditional dual-tip probes such as blinding, crawling, and drifting effects due to the interaction between the probe and bubbles can be prevented. The coherent signals reflected from both the front and rear ends of a bubble can provide velocity information. Deceleration of rising bubbles and particles due to the presence of the fiber probe is observed when they are very close to the fiber tip. With the residence time obtained, the bubble chord length can be determined by analyzing the coherent signal for velocity determination before the deceleration starts. The bubble diameters are directly obtained from analyzing the signals of the bubbles that contain velocity information. The chord lengths of these bubbles measured by FOR represent the bubble diameters when the bubble shape is spherical or represent the minor axes when the bubble shape is ellipsoidal. The velocity and size of bubbles obtained from the FOR measurements are compared with those obtained simultaneously using a high speed camera.

  8. Density perturbation mode structure of high frequency compressional and global Alfvén eigenmodes in the National Spherical Torus Experiment using a novel reflectometer analysis technique

    NASA Astrophysics Data System (ADS)

    Crocker, N. A.; Kubota, S.; Peebles, W. A.; Rhodes, T. L.; Fredrickson, E. D.; Belova, E.; Diallo, A.; LeBlanc, B. P.; Sabbagh, S. A.

    2018-01-01

    Reflectometry measurements of compressional (CAE) and global (GAE) Alfvén eigenmodes are analyzed to obtain the amplitude and spatial structure of the density perturbations associated with the modes. A novel analysis technique developed for this purpose is presented. The analysis also naturally yields the amplitude and spatial structure of the density contour radial displacement, which is found to be 2-4 times larger than the value estimated directly from the reflectometer measurements using the much simpler ‘mirror approximation’. The modes were driven by beam ions in a high power (6 MW) neutral beam heated H-mode discharge (#141398) in the National Spherical Torus Experiment. The results of the analysis are used to assess the contribution of the modes to core energy transport and ion heating. The total displacement amplitude of the modes, which is shown to be larger than previously estimated (Crocker et al 2013 Nucl. Fusion 53 43017), is compared to the predicted threshold (Gorelenkov et al 2010 Nucl. Fusion 50 84012) for the anomalously high heat diffusion inferred from transport modeling in similar NSTX discharges. The results of the analysis also have strong implications for the energy transport via coupling of CAEs to kinetic Alfvén waves seen in simulations with the Hybrid MHD code (Belova et al 2015 Phys. Rev. Lett. 115 15001). Finally, the amplitudes of the observed CAEs fall well below the threshold for causing significant ion heating by stochastic velocity space diffusion (Gates et al 2001 Phys. Rev. Lett. 87 205003).

  9. Evaluation of low-frequency operational limit of proposed ITER low-field-side reflectometer waveguide run including miter bends

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, Guiding; Peebles, W. A.; Doyle, E. J.

    The present design concept for the ITER low-field-side reflectometer transmission line (TL) consists of an ~40 m long, 6.35 cm diameter helically corrugated waveguide (WG) together with ten 90° miter bends. This paper presents an evaluation of the TL performance at low frequencies (33-50 GHz) where the predicted HE11 mode ohmic and mode conversion losses start to increase significantly. Quasi-optical techniques were used to form a near Gaussian beam to efficiently couple radiation in this frequency range into the WG. We observed that the output beams from the guide remained linearly polarized with cross-polarization power levels of ~1.5%-3%. The polarizationmore » rotation due to the helical corrugations was in the range ~1°-3°. The radiated beam power profiles typically show excellent Gaussian propagation characteristics at distances >20 cm from the final exit aperture. The round trip propagation loss was found to be ~2.5 dB at 50 GHz and ~6.5 dB at 35 GHz, showing an inverse increase with frequency. This was consistent with updated calculations of miter bend and ohmic losses. At low frequencies (33-50 GHz), the mode purity remained very good at the exit of the waveguide, and the losses are perfectly acceptable for operation in ITER. Finally, the primary challenge may come from the future addition of a Gaussian telescope and other filter components within the corrugated guide, which will likely introduce additional perturbations to the beam profile and an increase in mode-conversion loss.« less

  10. 76 FR 26290 - Science Advisory Board Staff Office; Notification of a Public Teleconference of the Chartered...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-05-06

    ... report entitled ``SAB Review of EPA's Reanalysis of Key Issues Related to Dioxin Toxicity and Response to... of EPA's Reanalysis of Key Issues Related to Dioxin Toxicity and Response to NAS Comments.'' The SAB... Reanalysis of Key Issues Related to Dioxin Toxicity and Response to NAS Comments.'' To conduct this review...

  11. Added value of involving patients in the first step of multidisciplinary guideline development: a qualitative interview study among infertile patients.

    PubMed

    den Breejen, Elvira M E; Hermens, Rosella P M G; Galama, Wienke H; Willemsen, Wim N P; Kremer, Jan A M; Nelen, Willianne L D M

    2016-06-01

    Patient involvement in scoping the guideline is emphasized, but published initiatives actively involving patients are generally limited to the writing and reviewing phase. To assess patients' added value to the scoping phase of a multidisciplinary guideline on infertility. Qualitative interview study. We conducted interviews among 12 infertile couples and 17 professionals. We listed and compared the couples' and professionals' key clinical issues (=care aspects that need improvement) to be addressed in the guideline according to four domains: current guidelines, professionals, patients and organization of care. Main key clinical issues suggested by more than three quarters of the infertile couples and/or at least two professionals were identified and compared. Overall, we identified 32 key clinical issues among infertile couples and 23 among professionals. Of the defined main key clinical issues, infertile couples mentioned eight issues that were not mentioned by the professionals. These main key clinical issues mainly concerned patient-centred (e.g. poor information provision and poor alignment of care) aspects of care on the professional and organizational domain. Both groups mentioned two main key clinical issues collectively that were interpreted differently: the lack of emotional support and respect for patients' values. Including patients from the first phase of the guideline development process leads to valuable additional main key clinical issues for the next step of a multidisciplinary guideline development process and broadens the scope of the guideline, particularly regarding patient-centredness and organizational issues from a patients' perspective. © The Author 2016. Published by Oxford University Press in association with the International Society for Quality in Health Care; all rights reserved.

  12. A view of software management issues

    NASA Technical Reports Server (NTRS)

    Manley, J. H.

    1985-01-01

    The Software Development Environment (SDE) Panel addressed key programmatic, scope, and structural issues raised by its members and the general audience regarding the proposed software development environment for the Space Station program. The general team approach taken by this group led to a consensus on 18 recommendations to NASA mangament regarding the acquisition and definition of the SDE. This approach was keyed by the initial issues presentation given to the general audience. Additional issues (for a total of 23) were developed by the panelists in their first closed session from which key areas were selected and discussed in open session. These discussions led to key recommendations which are summarized and described.

  13. Diffraction gratings metrology and ray-tracing results for an XUV Raman spectrometer at FLASH

    PubMed Central

    Dziarzhytski, Siarhei; Siewert, Frank; Gwalt, Grzegorz; Seliger, Tino; Rübhausen, Michael; Weigelt, Holger; Brenner, Günter

    2018-01-01

    The extreme-ultraviolet double-stage imaging Raman spectrometer is a permanent experimental endstation at the plane-grating monochromator beamline branch PG1 at FLASH at DESY in Hamburg, Germany. This unique instrument covers the photon energy range from 20 to 200 eV with high energy resolution of about 2 to 20 meV (design values) featuring an efficient elastic line suppression as well as effective stray light rejection. Such a design enables studies of low-energy excitations like, for example, phonons in solids close to the vicinity of the elastic line. The Raman spectrometer effectively operates with four reflective off-axial parabolic mirrors and two plane-grating units. The optics quality and their precise alignment are crucial to guarantee best performance of the instrument. Here, results on a comprehensive investigation of the quality of the spectrometer diffraction gratings are presented. The gratings have been characterized by ex situ metrology at the BESSY-II Optics Laboratory, employing slope measuring deflectometry and interferometry as well as atomic force microscopy studies. The efficiency of these key optical elements has been measured at the at-wavelength metrology laboratory using the reflectometer at the BESSY-II Optics beamline. Also, the metrology results are discussed with respect to the expected resolving power of the instrument by including them in ray-tracing studies of the instrument. PMID:29271763

  14. Far-infrared BRDFs and reflectance spectra of candidate SOFIA telescope, cavity, and focal-plane instrument surfaces

    NASA Astrophysics Data System (ADS)

    Meyer, Allan W.; Smith, Sheldon M.; Koerber, Christopher T.

    2000-06-01

    The far-infrared reflectance and scattering properties of telescope surfaces, surrounding cavity walls, and surfaces within focal-plane instruments can be significant contributors to background noise. Radiation from sources well off-axis, such as the earth, moon or aircraft engines may be multiply scattered by the cavity walls and/or surface facets of a complex telescope structure. The Non-Specular Reflectometer at NASA Ames Research Center was reactivated and upgraded, and used to measure reflectance and Bi- directional Reflectance Distribution Functions for samples of planned telescope system structural materials and associated surface treatments.

  15. Return to the red planet

    NASA Astrophysics Data System (ADS)

    Nichols, Robert G.

    1992-10-01

    The paper discusses the type of data which will be collected by the NASA's Mars Observer spacecraft when it reaches the planet next year. These will include measurements on the Martian magnetic field, the volcanic activity, the dust storms, seasonal weather cycles, and the planet's atmosphere and gravitational field. The Mars Observer's instruments include a magnetometer, an electron reflectometer, an IR radiometer, a laser altimeter, a thermal-emission spectrometer, a gamma-ray spectrometer, a camera, and a radio system. The program is counting on the vehicle's longevity so that it can participate in a Russian mission due to arrive at Mars in September 1995.

  16. Monitoring technique for a hybrid PS/WDM-PON by using a tunable OTDR and FBGs

    NASA Astrophysics Data System (ADS)

    Hann, Swook; Yoo, Jun-sang; Park, Chang-Soo

    2006-05-01

    A monitoring technique for hybrid passive optical networks (PON) is presented. The technique is based on the remote sensing of fibre Bragg gratings (FBGs) using a tunable optical time domain reflectometer (OTDR). The FBG would help discern an individual event during the monitoring of the hybrid PON in collaboration with the information provided by the Rayleigh backscattered power. The hybrid architecture of passive splitter-PON and WDM-PON can be analysed by the monitoring method by using the tunable OTDR and FBGs at the central office under the in-service state of PON.

  17. Study of Optical Fiber Sensors for Cryogenic Temperature Measurements.

    PubMed

    De Miguel-Soto, Veronica; Leandro, Daniel; Lopez-Aldaba, Aitor; Beato-López, Juan Jesus; Pérez-Landazábal, José Ignacio; Auguste, Jean-Louis; Jamier, Raphael; Roy, Philippe; Lopez-Amo, Manuel

    2017-11-30

    In this work, the performance of five different fiber optic sensors at cryogenic temperatures has been analyzed. A photonic crystal fiber Fabry-Pérot interferometer, two Sagnac interferometers, a commercial fiber Bragg grating (FBG), and a π-phase shifted fiber Bragg grating interrogated in a random distributed feedback fiber laser have been studied. Their sensitivities and resolutions as sensors for cryogenic temperatures have been compared regarding their advantages and disadvantages. Additionally, the results have been compared with the given by a commercial optical backscatter reflectometer that allowed for distributed temperature measurements of a single mode fiber.

  18. Fiber optic security seal including plural Bragg gratings

    DOEpatents

    Forman, P.R.

    1994-09-27

    An optical security system enables the integrity of a container seal to be remotely interrogated. A plurality of Bragg gratings is written holographically into the core of at least one optical fiber placed about the container seal, where each Bragg grating has a predetermined location and a known frequency for reflecting incident light. A time domain reflectometer is provided with a variable frequency light output that corresponds to the reflecting frequencies of the Bragg gratings to output a signal that is functionally related to the location and reflecting frequency of each of the Bragg gratings. 2 figs.

  19. Possible applications of time domain reflectometry in planetary exploration missions

    NASA Technical Reports Server (NTRS)

    Heckendorn, S.

    1982-01-01

    The use of a time domain reflectometer (TDR) for planetary exploration is considered. Determination of the apparent dielectric constant and hence, the volumetric water content of frozen and unfrozen soils using the TDR is described. Earth-based tests were performed on a New York state sandy soil and a Wyoming Bentonite. Use of both a cylindrical coaxial transmission line and a parallel transmission line as probes was evaluated. The water content of the soils was varied and the apparent dielectric constant measured in both frozen and unfrozen states. Advantages and disadvantages of the technique are discussed.

  20. Study of Optical Fiber Sensors for Cryogenic Temperature Measurements

    PubMed Central

    Leandro, Daniel; Lopez-Aldaba, Aitor; Beato-López, Juan Jesus; Pérez-Landazábal, José Ignacio; Auguste, Jean-Louis; Jamier, Raphael; Roy, Philippe; Lopez-Amo, Manuel

    2017-01-01

    In this work, the performance of five different fiber optic sensors at cryogenic temperatures has been analyzed. A photonic crystal fiber Fabry-Pérot interferometer, two Sagnac interferometers, a commercial fiber Bragg grating (FBG), and a π-phase shifted fiber Bragg grating interrogated in a random distributed feedback fiber laser have been studied. Their sensitivities and resolutions as sensors for cryogenic temperatures have been compared regarding their advantages and disadvantages. Additionally, the results have been compared with the given by a commercial optical backscatter reflectometer that allowed for distributed temperature measurements of a single mode fiber. PMID:29189755

  1. Education Studies: Issues & Critical Perspectives

    ERIC Educational Resources Information Center

    Kassem, Derek; Mufti, Emmanuel; Robinson, John

    2006-01-01

    This major text for Education Studies students provides a critical account of key issues in education today. The text features: (1) A critical analysis of key issues in Education Studies to encourage students' thinking about education in the broadest terms; (2) Themed sections with introductions to link the issues discussed in each chapter; (3)…

  2. Strategies of Educational Decentralization: Key Questions and Core Issues.

    ERIC Educational Resources Information Center

    Hanson, E. Mark

    1998-01-01

    Explains key issues and forces that shape organization and management strategies of educational decentralization, using examples from Colombia, Venezuela, Argentina, Nicaragua, and Spain. Core decentralization issues include national and regional goals, planning, political stress, resource distribution, infrastructure development, and job…

  3. The at-wavelength metrology facility for UV- and XUV-reflection and diffraction optics at BESSY-II

    PubMed Central

    Schäfers, F.; Bischoff, P.; Eggenstein, F.; Erko, A.; Gaupp, A.; Künstner, S.; Mast, M.; Schmidt, J.-S.; Senf, F.; Siewert, F.; Sokolov, A.; Zeschke, Th.

    2016-01-01

    A technology center for the production of high-precision reflection gratings has been established. Within this project a new optics beamline and a versatile reflectometer for at-wavelength characterization of UV- and XUV-reflection gratings and other (nano-) optical elements has been set up at BESSY-II. The Plane Grating Monochromator beamline operated in collimated light (c-PGM) is equipped with an SX700 monochromator, of which the blazed gratings (600 and 1200 lines mm−1) have been recently exchanged for new ones of improved performance produced in-house. Over the operating range from 10 to 2000 eV this beamline has very high spectral purity achieved by (i) a four-mirror arrangement of different coatings which can be inserted into the beam at different angles and (ii) by absorber filters for high-order suppression. Stray light and scattered radiation is removed efficiently by double sets of in situ exchangeable apertures and slits. By use of in- and off-plane bending-magnet radiation the beamline can be adjusted to either linear or elliptical polarization. One of the main features of a novel 11-axes reflectometer is the possibility to incorporate real life-sized gratings. The samples are adjustable within six degrees of freedom by a newly developed UHV-tripod system carrying a load up to 4 kg, and the reflectivity can be measured between 0 and 90° incidence angle for both s- and p-polarization geometry. This novel powerful metrology facility has gone into operation recently and is now open for external users. First results on optical performance and measurements on multilayer gratings will be presented here. PMID:26698047

  4. Use of different surface analysis techniques for the study of the photo-degradation of a polymeric matrix composite

    NASA Astrophysics Data System (ADS)

    Larena, A.; Ochoa, S. Jimenez de

    2004-11-01

    Polypropylene matrix composites, with different reinforcement degrees of long glass fibres, are usually used in different fields of the industry, like aeronautics or automotive. Owed to their huge application field, and work under diverse and severe conditions, samples of the materials were exposed to artificial accelerated photo ageing in UV chamber (Heraeus Xenotest 15OS). Although the oxidative mechanism of the PP is known enough, the fact that the material presents a high content of glass fibre, cause a surface degradation higher than that the case of no reinforced materials, owed to the presence of the fibres near the surface. In order to study this topographic modifications, the optical confocal microscopy is used that allows us the analysis of the material surface with more accuracy than a surface profiler, and with nanometric precision. We also want a correlation between surface degradation studied by confocal microscopy and reflectometer measurements. By this way, we can know the surface state, and the degradation evolution, by means of a set of easy measurements, taken with a portable reflectometer, in samples at work, without preparation. Since these materials shall fulfil some aesthetic requirements, we study also, by means of UV-vis spectroscopy, Yellow Index and White Index variations, trying to explain the photochemical processes causing these modifications. Also, the fact that these materials are usually subjected to surface treatments like adhesion or painting makes necessary the study of surface energy. We study the variation of this factor with exposing time and percentage of fibre, by means of contact angle measurements, with different liquids of known surface tensions.

  5. NGNP High Temperature Materials White Paper

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lew Lommers; George Honma

    2012-08-01

    This white paper is one in a series of white papers that address key generic issues of the combined construction and operating license (COL) pre-application program key generic issues for the Next Generation Nuclear Plant reactor using the prismatic block fuel technology. The purpose of the pre-application program interactions with the NRC staff is to reduce the time required for COL application review by identifying and addressing key regulatory issues and, if possible, obtaining agreements for their resolution

  6. Coalition Building for Adult Literacy: Historical and Organizational Perspectives.

    ERIC Educational Resources Information Center

    Newman, Anabel P.; Lehman, Bernadette

    Selected successful literacy coalitions were examined to identify key issues and trends in coalition building. The six key issues identified (focus and functions, funding, governance, membership, key figures, and evaluation) were used as a framework to review the early efforts, current activities, and future visions of literacy coalitions…

  7. New Borns...Getting a Good Start.

    ERIC Educational Resources Information Center

    Huraux-Rendu, Christine; And Others

    1991-01-01

    This issue of Children in the Tropics analyzes key issues relating to protecting the health of newborn infants. Many of the suggestions offered concern rudimentary health care situations in developing countries. Key issues are addressed in four sections. The first section discusses the early care and first medical examination of infants born in…

  8. The reflectance of Ames 24E, Infrablack, and Martin black. [anodizing coatings for far-infrared space telescopes

    NASA Technical Reports Server (NTRS)

    Smith, Sheldon M.

    1989-01-01

    Results are reported from measurements of the specular reflectances (SRs) and bidirectional reflectance distribution functions (BRDFs) of three black optical coatings in the FIR wavelength range. The nonspecular reflectometer apparatus described by Smith (1984) is employed, and the data are presented in tables and graphs and discussed in detail. It is found that Ames 24E has an FIR SR one order of magnitude lower than that of Martin black (MB), with BRDF values characteristic of a nearly Lambertian surface, while Infrablack has SR two orders lower than MB and a specular-diffuse surface; MB itself has a very specular surface.

  9. Spectral infrared hemispherical reflectance measurements for LDEF tray clamps

    NASA Technical Reports Server (NTRS)

    Cromwell, B. K.; Shepherd, S. D.; Pender, C. W.; Wood, B. E.

    1993-01-01

    Infrared hemispherical reflectance measurements that were made on 58 chromic acid anodized tray clamps from LDEF are described. The measurements were made using a hemiellipsoidal mirror reflectometer with interferometer for wavelengths between 2-15 microns. The tray clamps investigated were from locations about the entire spacecraft and provided the opportunity for comparing the effects of atomic oxygen at each location. Results indicate there was essentially no dependence on atomic oxygen fluence for the surfaces studied, but there did appear to be a slight dependence on solar radiation exposure. The reflectances of the front sides of the tray clamps consistently were slightly higher than for the protected rear tray clamp surfaces.

  10. Quality of dry chemistry testing.

    PubMed

    Nakamura, H; Tatsumi, N

    1999-01-01

    Since the development of the qualitative test paper for urine in 1950s, several kinds of dry-state-reagents and their automated analyzers have been developed. "Dry chemistry" has become to be called since the report on the development of quantitative test paper for serum bilirubin with reflectometer in the end of 1960s and dry chemistry has been world widely known since the presentation on the development of multilayer film reagent for serum biochemical analytes by Eastman Kodak Co at the 10th IFCC Meeting in the end of 1970s. We have reported test menu, results in external quality assessment, merits and demerits, and the future possibilities of dry chemistry.

  11. Performance assessment of geotechnical structural elements using distributed fiber optic sensing

    NASA Astrophysics Data System (ADS)

    Monsberger, Christoph; Woschitz, Helmut; Lienhart, Werner; Račanský, Václav; Hayden, Martin

    2017-04-01

    Geotechnical structural elements are used to underpin heavy structures or to stabilize slopes and embankments. The bearing capacity of these components is usually verified by geotechnical load tests. It is state of the art to measure the resulting deformations with electronic sensors at the surface and therefore, the load distribution along the objects cannot be determined. This paper reports about distributed strain measurements with an optical backscatter reflectometer along geotechnical elements. In addition to the installation of the optical fiber in harsh field conditions, results of investigations of the fiber optic system in the laboratory and the most significant results of the field trials are presented.

  12. Temperature measurements in an ytterbium fiber amplifier up to the mode instability threshold

    NASA Astrophysics Data System (ADS)

    Beier, F.; Heinzig, M.; Sattler, Bettina; Walbaum, Till; Haarlammert, N.; Schreiber, T.; Eberhardt, R.; Tünnermann, A.

    2016-03-01

    We report on the measurement of the longitudinal temperature distribution in a fiber amplifier fiber during high power operation. The measurement signal of an optical frequency domain reflectometer is coupled to an ytterbium doped amplifier fiber via a wavelength division multiplexer. The longitudinal temperature distribution was examined for different pump powers with a sub mm resolution. The results show even small temperature variations induced by slight changes of the environmental conditions along the fiber. The mode instability threshold of the fiber under investigation was determined to be 480W and temperatures could be measured overall the measured output power values.

  13. Technique for finding and identifying filters that cut off OTDR lights in front of ONU from a central office

    NASA Astrophysics Data System (ADS)

    Takaya, Masaaki; Honda, Hiroyasu; Narita, Yoshihiro; Yamamoto, Fumihiko; Arakawa, Koji

    2006-04-01

    We report on a newly developed in-service measurement technique that can be used from a central office to find and identify any filter in front of an ONU on an optical fiber access network. Using this system, in-service tests can be performed because the test lights are modulated at a high frequency. Moreover, by using the equipment we developed, this confirmation operation can be performed continuously and automatically with existing automatic fiber testing systems. The developed technique is effective for constructing a fiber line testing system with an optical time domain reflectometer.

  14. Identification and Characterization of Key Human Performance Issues and Research in the Next Generation Air Transportation System (NextGen)

    NASA Technical Reports Server (NTRS)

    Lee, Paul U.; Sheridan, Tom; Poage, james L.; Martin, Lynne Hazel; Jobe, Kimberly K.

    2010-01-01

    This report identifies key human-performance-related issues associated with Next Generation Air Transportation System (NextGen) research in the NASA NextGen-Airspace Project. Four Research Focus Areas (RFAs) in the NextGen-Airspace Project - namely Separation Assurance (SA), Airspace Super Density Operations (ASDO), Traffic Flow Management (TFM), and Dynamic Airspace Configuration (DAC) - were examined closely. In the course of the research, it was determined that the identified human performance issues needed to be analyzed in the context of NextGen operations rather than through basic human factors research. The main gaps in human factors research in NextGen were found in the need for accurate identification of key human-systems related issues within the context of specific NextGen concepts and better design of the operational requirements for those concepts. By focusing on human-system related issues for individual concepts, key human performance issues for the four RFAs were identified and described in this report. In addition, mixed equipage airspace with components of two RFAs were characterized to illustrate potential human performance issues that arise from the integration of multiple concepts.

  15. Task-Based Pronunciation Teaching and Research: Key Issues and Future Directions

    ERIC Educational Resources Information Center

    Mora, Joan C.; Levkina, Mayya

    2017-01-01

    This article synthesizes the conclusions of the empirical studies in this special issue and outlines key questions in future research. The research reported in this volume has identified several fundamental issues in pronunciation-focused task design that are discussed in detail and on which suggestions for further research are outlined. One…

  16. Key Policy Issues in the Implementation of User Choice. Working Paper No. 8.

    ERIC Educational Resources Information Center

    Smith, Joy Selby; Smith, Chris Selby; Ferrier, Fran

    This working paper examines key policy issues in the implementation of Australia's User Choice policy regarding allocating public funds for vocational education and training (VET). Part 1 explains the process used to obtain stakeholders regarding the User Choice policy, the administrative arrangements required to support it, and issues that must…

  17. Workplace wellness programs in Canada: an exploration of key issues.

    PubMed

    Morrison, Erin; MacKinnon, Neil J

    2008-01-01

    Faced with the reality of rising health costs, Canadian employers are thinking beyond traditional notions of responsibility for employee health and have begun to embrace Workplace Wellness Programs (WWPs). This article investigates the critical issues of WWPs in the Canadian context from the perspective of key stakeholders. Using a combination of literature and key informant interviews, seven key themes are presented along with recommendations for wider implementation of WWPs in Canada.

  18. The balancing act: key issues in the lives of women general practitioners in Australia.

    PubMed

    Kilmartin, Margaret R; Newell, Christopher J; Line, Martin A

    2002-07-15

    To identify key issues affecting women general practitioners in their professional and non-professional lives. A qualitative study using the Delphi technique, with three rounds of data provision circulated to each participant. Coding was used to ensure anonymity. The participants were a purposive sample of 40 women GPs drawn from all Australian States and Territories. The study was conducted between October 1996 and January 1997. Key issues affecting the professional and non-professional lives of women GPs. Some of the key professional issues for women GPs were job satisfaction, balancing work and personal life, autonomy, availability of flexible and part-time work and training, affordability of professional expenses, fair remuneration, and having a voice in decision-making. Key non-professional issues included self-care; time for relationships with a partner, children, family and friends; and time management to allow pursuit of non-medical interests. The conflicting demands made on women GPs diminish their job satisfaction and lead to stress and imbalance in their lives. Recommendations to ameliorate the problems for women GPs include appropriate training, policy formation, financial and other support, and a change in cultural expectations of women GPs by the community, the profession and governments.

  19. Key Higher-Education Issues in the States

    ERIC Educational Resources Information Center

    Fischer, Karin; Hebel, Sara

    2007-01-01

    Legislatures are set to convene in January in 43 states. This article presents the key issues that are expected to be debated by legislatures in states this year. These issues include: (1) Annulment of a controversial law in Texas that guarantees students who graduate in the top 10 percent of their high-school classes admission to any public…

  20. Understanding Key Education Issues: How We Got Here and Where We Go from Here

    ERIC Educational Resources Information Center

    Lynch, Matthew

    2017-01-01

    In this age of education innovation and reform, schools must evolve and react to current policy trends. This accessible book offers research-based insights into six key educational trends and issues that are impacting K-12 learning today: year-round schooling, assessments, educating minorities, anti-intellectualism, issues of social promotion and…

  1. Human health monitoring technology

    NASA Astrophysics Data System (ADS)

    Kim, Byung-Hyun; Yook, Jong-Gwan

    2017-05-01

    Monitoring vital signs from human body is very important to healthcare and medical diagnosis, because they contain valuable information about arterial occlusions, arrhythmia, atherosclerosis, autonomous nervous system pathologies, stress level, and obstructive sleep apnea. Existing methods, such as electrocardiogram (ECG) sensor and photoplethysmogram (PPG) sensor, requires direct contact to the skin and it can causes skin irritation and the inconvenience of long-term wearing. For reducing the inconvenience in the conventional sensors, microwave and millimeter-wave sensors have been proposed since 1970s using micro-Doppler effect from one's cardiopulmonary activity. The Doppler radar sensor can remotely detect the respiration and heartbeat up to few meters away from the subject, but they have a multiple subject issue and are not suitable for an ambulatory subject. As a compromise, a noncontact proximity vital sign sensor has been recently proposed and developed. The purpose of this paper is to review the noncontact proximity vital sign sensors for detection of respiration, heartbeat rate, and/or wrist pulse. This sensor basically employs near-field perturbation of radio-frequency (RF) planar resonator due to the proximity of the one's chest or radial artery at the wrist. Various sensing systems based on the SAW filter, phase-locked loop (PLL) synthesizer, reflectometer, and interferometer have been proposed. These self-sustained systems can measure the nearfield perturbation and transform it into DC voltage variation. Consequently, they can detect the respiration and heartbeat rate near the chest of subject and pulse from radial artery at the wrist.

  2. For Dr. Nancy Snyderman's Parents, Staying Close to Family Is Key

    MedlinePlus

    ... Issues Feature: Senior Living For Dr. Nancy Snyderman's Parents, Staying Close to Family Is Key Past Issues / ... home. "Watching my children grow closer to my parents has been a blessing, and having us nearby ...

  3. Washington state short line rail inventory and needs assessment.

    DOT National Transportation Integrated Search

    2015-06-01

    The recently completed State Rail Plan for the state of Washington identified several key issues facing the states : rail system. Among these key issues are abandonment, port access and competitive needs of the ports and local : production regions...

  4. Key Issues in Instructional Computer Graphics.

    ERIC Educational Resources Information Center

    Wozny, Michael J.

    1981-01-01

    Addresses key issues facing universities which plan to establish instructional computer graphics facilities, including computer-aided design/computer aided manufacturing systems, role in curriculum, hardware, software, writing instructional software, faculty involvement, operations, and research. Thirty-seven references and two appendices are…

  5. Towards optimised information about clinical trials; identification and validation of key issues in collaboration with cancer patient advocates.

    PubMed

    Dellson, P; Nilbert, M; Bendahl, P-O; Malmström, P; Carlsson, C

    2011-07-01

    Clinical trials are crucial to improve cancer treatment but recruitment is difficult. Optimised patient information has been recognised as a key issue. In line with the increasing focus on patients' perspectives in health care, we aimed to study patients' opinions about the written information used in three clinical trials for breast cancer. Primary data collection was done in focus group interviews with breast cancer patient advocates. Content analysis identified three major themes: comprehensibility, emotions and associations, and decision making. Based on the advocates' suggestions for improvements, 21 key issues were defined and validated through a questionnaire in an independent group of breast cancer patient advocates. Clear messages, emotionally neutral expressions, careful descriptions of side effects, clear comparisons between different treatment alternatives and information about the possibility to discontinue treatment were perceived as the most important issues. Patients' views of the information in clinical trials provide new insights and identify key issues to consider in optimising future written information and may improve recruitment to clinical cancer trials. © 2010 Blackwell Publishing Ltd.

  6. A summary and integration of research concerning single pilot IFR operational problems

    NASA Technical Reports Server (NTRS)

    Chapman, G. C.

    1983-01-01

    A review of seven research studies pertaining to Single Pilot IFR (SPIFR) operations was performed. Two studies were based on questionnaire surveys; two based on National Transportation Safety Board (NTSB) reports; two were based on Aviation Safety Reporting System (ASRS) incident reports, and one report used event analysis and statistics to forecast problems. The results obtained in each study were extracted and integrated. Results were synthesized and key issues pertaining to SPIFR operations problems were identified. The research that was recommended by the studies and that addressed the key issues is catalogued for each key issue.

  7. Application of the Haar Wavelet to the Analysis of Plasma and Atmospheric Fluctuations

    NASA Astrophysics Data System (ADS)

    Maslov, S. A.; Kharchevsky, A. A.; Smirnov, V. A.

    2017-12-01

    The parameters of turbulence measured by means of a Doppler reflectometer at the plasma periphery in an L-2M stellarator and in atmospheric vortices (typhoons and tornadoes) are investigated using the wavelet methods with involvement of the Haar function. The periods of time taken for the transition (a bound of parameters) to occur in the L-2M stellarator plasma and in atmospheric processes are estimated. It is shown that high-and low-frequency oscillations of certain parameters, in particular, pressure, that occur in atmospheric vortices decay or increase at different moments of time, whereas the density fluctuation amplitudes that occur in plasma at different frequencies vary in a synchronous manner.

  8. A millimeter-wave reflectometer for whole-body hydration sensing

    NASA Astrophysics Data System (ADS)

    Zhang, W.-D.; Brown, E. R.

    2016-05-01

    This paper demonstrates a non-invasive method to determine the hydration level of human skin by measuring the reflectance of W-band (75-110 GHz) and Ka-band (26-40 GHz) radiation. Ka-band provides higher hydration accuracy (<1%) and greater depth of penetration (> 1 mm), thereby allowing access to the important dermis layer of skin. W-band provides less depth of penetration but finer spatial resolution (~2 mm). Both the hydration sensing concept and experimental results are presented here. The goal is to make a human hydration sensor that is 1% accurate or better, operable by mechanically scanning, and fast enough to measure large areas of the human body in seconds.

  9. Distributed fiber optical sensing of oxygen with optical time domain reflectometry.

    PubMed

    Eich, Susanne; Schmälzlin, Elmar; Löhmannsröben, Hans-Gerd

    2013-05-31

    In many biological and environmental applications spatially resolved sensing of molecular oxygen is desirable. A powerful tool for distributed measurements is optical time domain reflectometry (OTDR) which is often used in the field of telecommunications. We combine this technique with a novel optical oxygen sensor dye, triangular-[4] phenylene (TP), immobilized in a polymer matrix. The TP luminescence decay time is 86 ns. The short decay time of the sensor dye is suitable to achieve a spatial resolution of some meters. In this paper we present the development and characterization of a reflectometer in the UV range of the electromagnetic spectrum as well as optical oxygen sensing with different fiber arrangements.

  10. Distributed Fiber Optical Sensing of Oxygen with Optical Time Domain Reflectometry

    PubMed Central

    Eich, Susanne; Schmälzlin, Elmar; Löhmannsröben, Hans-Gerd

    2013-01-01

    In many biological and environmental applications spatially resolved sensing of molecular oxygen is desirable. A powerful tool for distributed measurements is optical time domain reflectometry (OTDR) which is often used in the field of telecommunications. We combine this technique with a novel optical oxygen sensor dye, triangular-[4] phenylene (TP), immobilized in a polymer matrix. The TP luminescence decay time is 86 ns. The short decay time of the sensor dye is suitable to achieve a spatial resolution of some meters. In this paper we present the development and characterization of a reflectometer in the UV range of the electromagnetic spectrum as well as optical oxygen sensing with different fiber arrangements. PMID:23727953

  11. Polarization effects on hard target calibration of lidar systems

    NASA Technical Reports Server (NTRS)

    Kavaya, Michael J.

    1987-01-01

    The theory of hard target calibration of lidar backscatter data, including laboratory measurements of the pertinent target reflectance parameters, is extended to include the effects of polarization of the transmitted and received laser radiation. The bidirectional reflectance-distribution function model of reflectance is expanded to a 4 x 4 matrix allowing Mueller matrix and Stokes vector calculus to be employed. Target reflectance parameters for calibration of lidar backscatter data are derived for various lidar system polarization configurations from integrating sphere and monostatic reflectometer measurements. It is found that correct modeling of polarization effects is mandatory for accurate calibration of hard target reflectance parameters and, therefore, for accurate calibration of lidar backscatter data.

  12. Far-infrared /FIR/ optical black bidirectional reflectance distribution function /BRDF/

    NASA Technical Reports Server (NTRS)

    Smith, S. M.

    1981-01-01

    A nonspecular reflectometer and its operation at far-infrared wavelengths are described. Large differences in nonspecular reflectance were found to exist between different optically black coatings. Normal incidence bidirectional reflectance distribution function /BRDF) measurements at wavelengths between 12 and 316 microns of three black coatings show that their mean BRDFs increase with wavelength. The specularity of two of these coatings also showed a strong wavelength dependence, while the specularity of one coating seemed independent of wavelength. The BRDF of one coating depended on the angle of incidence at 12 and 38 microns, but not at 316 microns. Beyond 200 microns, it was found necessary to correct the measurements for the beam spread of the instrument.

  13. Metal-coated Bragg grating reflecting fibre

    NASA Astrophysics Data System (ADS)

    Chamorovskiy, Yu. K.; Butov, O. V.; Kolosovskiy, A. O.; Popov, S. M.; Voloshin, V. V.; Vorob'ev, I. L.; Vyatkin, M. Yu.

    2017-03-01

    High-temperature optical fibres (OF) with fibre Bragg gratings (FBG) arrays written over a long length and in-line metal coating have been made for the first time. The optical parameters of the FBG arrays were tested by the optical frequency domain reflectometer (OFDR) method in a wide temperature range, demonstrating no degradation in reflection at heating up to 600 °C for a fibre with Al coating. The mechanical strength of the developed fibre was practically the same as "ordinary" OF with similar coating, showing the absence of the influence of FBG writing process on fibre strength. Further experiments are necessary to evaluate the possibility of further increases in the operational temperature range.

  14. Update to permeable pavement research at the Edison ...

    EPA Pesticide Factsheets

    Abstract: The EPA’s Urban Watershed Management Branch (UWMB) has been monitoring the permeable pavement demonstration site at the Edison Environmental Center, NJ since 2010. This site has three different types of permeable pavement including: interlocking concrete permeable pavers; porous concrete; and permeable asphalt. The parking lot is instrumented with water content reflectometers and thermistors for continuous monitoring and has four lined sections for each surface to capture permeable pavement infiltrate for water quality analyses.Previous technical releases concerning the demonstration site focused on monitoring techniques, observed chloride and nutrient concentrations, and infiltration and evaporation rates. Thispresentation summarizes past findings and addresses current water quality efforts. This presentation summarizes past findings and addresses current water quality efforts.

  15. Impacts on non-human biota from a generic geological disposal facility for radioactive waste: some key assessment issues.

    PubMed

    Robinson, C A; Smith, K L; Norris, S

    2010-06-01

    This paper provides an overview of key issues associated with the application of currently available biota dose assessment methods to consideration of potential environmental impacts from geological disposal facilities. It explores philosophical, methodological and practical assessment issues and reviews the implications of test assessment results in the context of recent and on-going challenges and debates.

  16. Cleaning by clustering: methodology for addressing data quality issues in biomedical metadata.

    PubMed

    Hu, Wei; Zaveri, Amrapali; Qiu, Honglei; Dumontier, Michel

    2017-09-18

    The ability to efficiently search and filter datasets depends on access to high quality metadata. While most biomedical repositories require data submitters to provide a minimal set of metadata, some such as the Gene Expression Omnibus (GEO) allows users to specify additional metadata in the form of textual key-value pairs (e.g. sex: female). However, since there is no structured vocabulary to guide the submitter regarding the metadata terms to use, consequently, the 44,000,000+ key-value pairs in GEO suffer from numerous quality issues including redundancy, heterogeneity, inconsistency, and incompleteness. Such issues hinder the ability of scientists to hone in on datasets that meet their requirements and point to a need for accurate, structured and complete description of the data. In this study, we propose a clustering-based approach to address data quality issues in biomedical, specifically gene expression, metadata. First, we present three different kinds of similarity measures to compare metadata keys. Second, we design a scalable agglomerative clustering algorithm to cluster similar keys together. Our agglomerative cluster algorithm identified metadata keys that were similar, based on (i) name, (ii) core concept and (iii) value similarities, to each other and grouped them together. We evaluated our method using a manually created gold standard in which 359 keys were grouped into 27 clusters based on six types of characteristics: (i) age, (ii) cell line, (iii) disease, (iv) strain, (v) tissue and (vi) treatment. As a result, the algorithm generated 18 clusters containing 355 keys (four clusters with only one key were excluded). In the 18 clusters, there were keys that were identified correctly to be related to that cluster, but there were 13 keys which were not related to that cluster. We compared our approach with four other published methods. Our approach significantly outperformed them for most metadata keys and achieved the best average F-Score (0.63). Our algorithm identified keys that were similar to each other and grouped them together. Our intuition that underpins cleaning by clustering is that, dividing keys into different clusters resolves the scalability issues for data observation and cleaning, and keys in the same cluster with duplicates and errors can easily be found. Our algorithm can also be applied to other biomedical data types.

  17. Listening for Prescriptions: A National Consultation on Pharmaceutical Policy Issues

    PubMed Central

    Morgan, Steve; Cunningham, Colleen M.

    2010-01-01

    Objectives and Methods: Pharmaceutical policy is an increasingly costly, essential and challenging component of health system management. We sought to identify priority pharmaceutical policy issues in Canada and to translate them into research priorities using key informant interviews, stakeholder surveys and a deliberative workshop. Results: We found consensus on overarching policy goals: to provide all Canadians with equitable and sustainable access to necessary medicines. We also found widespread frustration that many key pharmaceutical policy issues in Canada — including improving prescription drug financing and pricing — have been persistent challenges owing to a lack of policy coordination. The coverage of extraordinarily costly medicines for serious conditions was identified as a rapidly emerging policy issue. Conclusion: Targeted research and knowledge translation activities can help address key policy issues and, importantly, challenges of policy coordination in Canada and thereby reduce inequity and inefficiency in policy approaches and outcomes. PMID:22043223

  18. Inner Space and Outer Space: Pressure Suits & Life Support Systems for Space Workers

    NASA Technical Reports Server (NTRS)

    Webbon, Bruce

    2004-01-01

    This slide presentation presents an overview of work system requirements, extravehicular activity system evolution, key issues, future needs, and a summary. Key issues include pressure suits, life support systems, system integration, biomedical requirements, and work and mobility aids.

  19. Key water issues now facing our nation

    USGS Publications Warehouse

    Hirsch, Robert M.; Miller, Timothy L.; Hamilton, Pixie A.; Gilliom, Robert J.

    2008-01-01

    Challenges to sustaining sufficient and high-quality water for human consumption, industry, farms, energy production, and ecosystem services continue to intensify in many parts of the Nation. We face four key water issues that call for support from the science and engineering communities.

  20. Will we outlive our money?

    PubMed

    Salisbury, D L

    2000-01-01

    Fewer and fewer Americans retire with benefits in the form of life annuities. The author raises key issues regarding the increased importance that uncertainty plays in determining retirement income. The key issues include longevity risk and how savings withdrawals rates will be affected at varying rates of return.

  1. Measuring Mars' Atmospheric Neutral Density from 160 to 220km with the MGS Electron Reflectometer

    NASA Astrophysics Data System (ADS)

    Lillis, R.; Engel, J.; Mitchell, D.; Brain, D.; Lin, R.; Bougher, S.; Acuna, M.

    2005-08-01

    The Magnetometer/Electron Reflectometer (MAG/ER) experiment aboard Mars Global Surveyor (MGS) samples the local electron population's distribution in energy and pitch angle (angle between electron velocity and local magnetic field direction) at the mapping orbit altitude of ˜400km. We develop a single-particle model of the electrons' interaction with the neutral atmosphere and motion along open field-lines connecting the solar wind to remnant crustal magnetization. Electron reflection from magnetic gradients and absorption due to inelastic collisons with atmospheric neutrals results in characteristic pitch angle (PA) distributions for open field lines. By assuming the validity of spherical harmonic expansions (Cain et al, 2003) in the strongest field regions of Mars (such as Terra Sirenum), we trace the electron paths and fit these PA distributions to our model to constrain the scale height and density of the neutral atmosphere in the region of greatest absorption, 160-220km. We analyse almost 3 martian years of MGS mapping Orbit Data and present the first measurements of Mars' neutral density above 180km. Although the uncertainties in single measurements are quite large, averaging over many measurements over a period of weeks allows us to see long-term trends. Major results are: 1) a mean density of 0.03 kg/km3 at 160km with a month-averaged variation of ˜40%, 2) a very strong annual seasonal variation, confirmed by periodogram and least-squares fit and 3) increasing seasonal density variability with distance from the equator. We see broad general agreement with predictions from Mars Thermosphere Global Circulation Model (MTGCM) simulations [Bougher et al, 2004] and with inferred densities from MGS Doppler tracking data [Tracadas et al, 2001]. Our results will help to constrain the upper boundaries of GCMs and assist orbital decay calculations for low-orbiting spacecraft, such as the 2005 Mars Reconnaissance Orbiter. We thank the NASA Jet Propulsion Laboratory for funding assistance for this research.

  2. Evaluation of quick tests for phosphorus determination in dairy manures.

    PubMed

    Lugo-Ospina, A; Dao, Thanh H; Van Kessel, J A; Reeves, J B

    2005-05-01

    Nutrients in animal manure are valuable inputs in agronomic crop production. Rapid and timely information about manure nutrient content are needed to minimize the risks of phosphorus (P) over-application and losses of dissolved P (DP) in runoff from fields treated with manure. We evaluated the suitability of a commercial hand-held reflectometer, a hydrometer, and an electrical conductivity (EC) meter for determining DP and total P (TP) in dairy manures. Bulk samples (n = 107) collected from farms across CT, MD, NY, PA, and VA were highly variable in total solids (TS) concentration, ranging from 11 to 213gL(-1), in suspensions' pH (6.3-9.2), and EC (6.2-53.3 dS m(-1)). Manure DP concentrations measured using the RQFlex reflectometer (RQFlex-DP(s)) were related to molybdate-reactive P (MRP(s)) concentrations as follows: RQFlex-DP(s) = 0.471 x MRP(s) + 1102 (r2 = 0.29). Inclusion of pH and squared-pH terms improved the prediction of manure DP from RQFlex results (r2 = 0.66). Excluding five outlier samples that had pH < or = 6.9 the coefficient of determination (r2) for the MRP(s) and RQFlex-DP(s) relationship was 0.83 for 95% of the samples. Manure TS were related to hydrometer specific gravity readings (r2 = 0.53) that were in turn related to TP (r2 = 0.34), but not to either RQFlex-DP or MRP. Relationships between suspensions' EC and DP or TP were non-significant. Therefore, the RQFlex method is the only viable option for on-site quick estimates of DP that can be made more robust when complemented with TS and pH measurements. The DP quick test can provide near real-time information on soluble manure nutrient content across a wide range of handling and storage conditions on dairy farms and quick estimates of potential soluble P losses in runoff following land applications of manure.

  3. Effectiveness of Cool Roof Coatings with Ceramic Particles

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brehob, Ellen G; Desjarlais, Andre Omer; Atchley, Jerald Allen

    2011-01-01

    Liquid applied coatings promoted as cool roof coatings, including several with ceramic particles, were tested at Oak Ridge National Laboratory (ORNL), Oak Ridge, Tenn., for the purpose of quantifying their thermal performances. Solar reflectance measurements were made for new samples and aged samples using a portable reflectometer (ASTM C1549, Standard Test Method for Determination of Solar Reflectance Near Ambient Temperature Using a Portable Solar Reflectometer) and for new samples using the integrating spheres method (ASTM E903, Standard Test Method for Solar Absorptance, Reflectance, and Transmittance of Materials Using Integrating Spheres). Thermal emittance was measured for the new samples using amore » portable emissometer (ASTM C1371, Standard Test Method for Determination of Emittance of Materials Near Room 1 Proceedings of the 2011 International Roofing Symposium Temperature Using Portable Emissometers). Thermal conductivity of the coatings was measured using a FOX 304 heat flow meter (ASTM C518, Standard Test Method for Steady-State Thermal Transmission Properties by Means of the Heat Flow Meter Apparatus). The surface properties of the cool roof coatings had higher solar reflectance than the reference black and white material, but there were no significant differences among coatings with and without ceramics. The coatings were applied to EPDM (ethylene propylene diene monomer) membranes and installed on the Roof Thermal Research Apparatus (RTRA), an instrumented facility at ORNL for testing roofs. Roof temperatures and heat flux through the roof were obtained for a year of exposure in east Tennessee. The field tests showed significant reduction in cooling required compared with the black reference roof (~80 percent) and a modest reduction in cooling compared with the white reference roof (~33 percent). The coating material with the highest solar reflectivity (no ceramic particles) demonstrated the best overall thermal performance (combination of reducing the cooling load cost and not incurring a large heating penalty cost) and suggests solar reflectivity is the significant characteristic for selecting cool roof coatings.« less

  4. Uncertainty and Variability in Physiologically-Based Pharmacokinetic (PBPK) Models: Key Issues and Case Studies (Final Report)

    EPA Science Inventory

    EPA announced the availability of the final report, Uncertainty and Variability in Physiologically-Based Pharmacokinetic (PBPK) Models: Key Issues and Case Studies. This report summarizes some of the recent progress in characterizing uncertainty and variability in physi...

  5. Ethics guidelines, health research and Indigenous Australians.

    PubMed

    Anderson, Ian; Griew, Robert; McAullay, Daniel

    2003-02-01

    In this paper we overview the findings of a literature review that was undertaken to guide the revision of the Guidelines on Ethical Matters in Aboriginal and Torres Strait Islander Health Research (NH&MRC, 1991). The literature reviewed, in general, supported the development of specific research guidelines for Aboriginal and Torres Strait Islander contexts. The findings of this review were analysed thematically, and a number of key issues were identified for consideration in the review process. We present a summary of these key issues. In the final section of the paper we consider in more detail two of the key issues raised in the review process (the assessment of relevance or benefit of proposed research; and the process of consultation and negotiation of collective consent) in order to critically consider how these issue should be engaged in revised guidelines. On the basis of this analysis, it is our contention that specific guidelines on key issues are limited to the extent to which they can anticipate all possible research contexts. In order to address this problem, and guide researchers, guidelines should also explicitly outline the values, from an Aboriginal and Torres Islander perspective that are foundational to an ethical research process.

  6. Child Care Briefing Book.

    ERIC Educational Resources Information Center

    Adams, Gina; Poersch, Nicole Oxendine

    This report provides information on a range of key child care issues, including basic facts about child care and its importance to children, families, and communities; and information on key legislative issues and proposals affecting child care. Fact sheets, with supporting references and tabular data, comprise about one-half of the document.…

  7. Issues in Moderation of National Curriculum Assessment at Key Stage 3.

    ERIC Educational Resources Information Center

    Cowling, Les

    1994-01-01

    Highlights the issues of moderation of teacher judgments for accountability and moderation for achieving consistent assessments. Discusses the meaning of moderation, the need for moderating teacher judgments, approaches to moderation, methods of moderation, and most appropriate methods of moderation at Key Stage 3. Presents an approach to…

  8. Gloss measurements and rugometric inspection in dental biomaterials

    NASA Astrophysics Data System (ADS)

    Fernández-Oliveras, Alicia; Costa, Manuel F. M.; Yebra, Ana; Rubiño, Manuel; Pérez, María. M.

    2013-11-01

    In dental applications, optimizing appearance is desirable and increasingly demanded by patients. The specular gloss is among the major appearance properties of dental biomaterials, and its relationship with surface roughness has been reported. Roughness and gloss are key surface aspects that complement each other. We have experimentally analyzed the specular gloss and surface roughness of two different types of dental-resin composites and pre-sintered and sintered zirconia ceramics. We have studied two shades of both composite types and two sintered zirconia ceramics: colored and uncolored. Moreover, a surface treatment was applied to one specimen of each dental resin. Gloss measurements were performed with a standardized reflectometer and the corresponding gloss percentages were calculated. All the samples were submitted to rugometric non-invasive inspection with the MICROTOP.06.MFC laser microtopographer in order to determine meaningful statistical parameters such as the average roughness (Ra) and the root-mean-square deviation (Rq). For a comparison of the different biomaterials, the uncertainties associated to the measure of the surface gloss and roughness were also determined. The differences between the two shades of both kinds of composites proved significant in the case of the roughness parameters but not for the specular gloss. The surface treatment applied to the dental-resin composites increased the average roughness but the changes in the specular gloss were significant only for the A2 enamel nano-composite. For the zirconia ceramic the sintered process resulted in an increase in the surface roughness with a decrease of the specular gloss, corroborating that the relationship between the gloss and the roughness shows the expected behavior.

  9. Multiplexed neural recording along a single optical fiber via optical reflectometry

    PubMed Central

    Rodriques, Samuel G.; Marblestone, Adam H.; Scholvin, Jorg; Dapello, Joel; Sarkar, Deblina; Mankin, Max; Gao, Ruixuan; Wood, Lowell; Boyden, Edward S.

    2016-01-01

    Abstract. We introduce the design and theoretical analysis of a fiber-optic architecture for neural recording without contrast agents, which transduces neural electrical signals into a multiplexed optical readout. Our sensor design is inspired by electro-optic modulators, which modulate the refractive index of a waveguide by applying a voltage across an electro-optic core material. We estimate that this design would allow recording of the activities of individual neurons located at points along a 10-cm length of optical fiber with 40-μm axial resolution and sensitivity down to 100  μV using commercially available optical reflectometers as readout devices. Neural recording sites detect a potential difference against a reference and apply this potential to a capacitor. The waveguide serves as one of the plates of the capacitor, so charge accumulation across the capacitor results in an optical effect. A key concept of the design is that the sensitivity can be improved by increasing the capacitance. To maximize the capacitance, we utilize a microscopic layer of material with high relative permittivity. If suitable materials can be found—possessing high capacitance per unit area as well as favorable properties with respect to toxicity, optical attenuation, ohmic junctions, and surface capacitance—then such sensing fibers could, in principle, be scaled down to few-micron cross-sections for minimally invasive neural interfacing. We study these material requirements and propose potential material choices. Custom-designed multimaterial optical fibers, probed using a reflectometric readout, may, therefore, provide a powerful platform for neural sensing. PMID:27194640

  10. Spectralon solar diffuser BRDF variation for NPP, JPSS J1 and J2

    NASA Astrophysics Data System (ADS)

    Murgai, Vijay; Johnson, Lindsay; Klein, Staci

    2017-09-01

    The Visible/Infrared Imaging Radiometer Suite (VIIRS) is a key sensor on the Suomi National Polar-orbiting Partnership (NPP) satellite as well as the upcoming Joint Polar Satellite System (JPSS). VIIRS collects Earth radiometric and imagery data in 22 spectral bands from 0.4 to 12.5 μm. Radiometric calibration of the reflective bands in the 0.4 to 2.5 μm wavelength range is performed by measuring the sunlight reflectance from Spectralon®. Reflected sun light is directly proportional to the Bidirectional Reflectance Distribution Function (BRDF) of the Spectralon. This paper presents the BRDF measurements of the Spectralon for JPSS J2 in the 0.4 - 1.63 μm wavelength using PASCAL (Polarization And Scatter Characterization Analysis of Lambertian materials) with an uncertainty better than 1.2%. PASCAL makes absolute measurements of the BRDF in an analogous fashion to the National Institute of Standards and Technology (NIST) Spectral Tri-function Automated Reflectance Reflectometer (STARR) facility. Unique additional features of this instrument include the ability to vary the sample elevation and roll / clock the sample about its normal, allowing measurement of BRDF in the as used geometry. Comparison of BRDF in the as used configuration for NPP, J1, and J2 shows variation of up to 3%. The sign of the change from panel to panel depends on the angle of incidence and view angle. The results demonstrate lot to lot variability in Spectralon and emphasize the necessity of characterizing each panel. A pattern in the BRDF variation is also presented.

  11. An Illumination Modeling System for Human Factors Analyses

    NASA Technical Reports Server (NTRS)

    Huynh, Thong; Maida, James C.; Bond, Robert L. (Technical Monitor)

    2002-01-01

    Seeing is critical to human performance. Lighting is critical for seeing. Therefore, lighting is critical to human performance. This is common sense, and here on earth, it is easily taken for granted. However, on orbit, because the sun will rise or set every 45 minutes on average, humans working in space must cope with extremely dynamic lighting conditions. Contrast conditions of harsh shadowing and glare is also severe. The prediction of lighting conditions for critical operations is essential. Crew training can factor lighting into the lesson plans when necessary. Mission planners can determine whether low-light video cameras are required or whether additional luminaires need to be flown. The optimization of the quantity and quality of light is needed because of the effects on crew safety, on electrical power and on equipment maintainability. To address all of these issues, an illumination modeling system has been developed by the Graphics Research and Analyses Facility (GRAF) and Lighting Environment Test Facility (LETF) in the Space Human Factors Laboratory at NASA Johnson Space Center. The system uses physically based ray tracing software (Radiance) developed at Lawrence Berkeley Laboratories, a human factors oriented geometric modeling system (PLAID) and an extensive database of humans and environments. Material reflectivity properties of major surfaces and critical surfaces are measured using a gonio-reflectometer. Luminaires (lights) are measured for beam spread distribution, color and intensity. Video camera performances are measured for color and light sensitivity. 3D geometric models of humans and the environment are combined with the material and light models to form a system capable of predicting lighting conditions and visibility conditions in space.

  12. Studies of electrochemical interfaces by TOF neutron reflectometry at the IBR-2 reactor

    NASA Astrophysics Data System (ADS)

    Petrenko, V. I.; Gapon, I. V.; Rulev, A. A.; Ushakova, E. E.; Kataev, E. Yu; Yashina, L. V.; Itkis, D. M.; Avdeev, M. V.

    2018-03-01

    The operation performance of electrochemical energy conversion and storage systems such as supercapacitors and batteries depends on the processes occurring at the electrochemical interfaces, where charge separation and chemical reactions occur. Here, we report about the tests of the neutron reflectometry cells specially designed for operando studies of structural changes at the electrochemical interfaces between solid electrodes and liquid electrolytes. The cells are compatible with anhydrous electrolytes with organic solvents, which are employed today in all lithium ion batteries and most supercapacitors. The sensitivity of neutron reflectometry applied at the time-of-flight (TOF) reflectometer at the pulsed reactor IBR-2 is discussed regarding the effect of solid electrolyte interphase (SEI) formation on metal electrode surface.

  13. Calibration and standards beamline 6.3.2 at the ALS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Underwood, J.H.; Gullikson, E.M.; Koike, M.

    1997-04-01

    More sophisticated optics for the x-ray, soft x-ray and far ultraviolet spectral regions being developed for synchrotron radiation research and many other applications, require accurate calibration and standards facilities for measuring reflectivity of mirrors and multilayer coatings, transmission of thin films, bandpass of multilayers, efficiency of gratings or detectors, etc. For this purpose beamline 6.3.2 was built at the ALS. Its energy coverage, versatility, simplicity and convenience also make it useful for a wide range of other experiments. The paper describes the components of this beamline, consisting of: a four jaw aperture; a horizontal focusing mirror; a monochromator; exit slit;more » vertical focusing mirror; mechanical and vacuum system; reflectometer; filter wheels; and data acquisition system.« less

  14. AWG-based WDM-PON monitoring system using an optical switch and a WDM filter

    NASA Astrophysics Data System (ADS)

    Liaw, S.-K.; Lai, Y.-T.; Chang, C.-L.; Shung, O.

    2008-09-01

    A new WDM-PON scheme with real-time monitoring based on a time-sharing method is proposed. It uses an optical time domain reflectometer (OTDR) to monitor multiple ports by integrating an optical switch (OSW) with a dense wavelength division multiplexer (DWDM) at the optical line terminal (OLT) site. Each downstream signal and its corresponding monitoring signal are separated by m times the free-space range (FSR) of an array waveguide grating (AWG). A bit error rate (BER) test in 2.5 Gb/s × 27 km is performed with and without turning on the OTDR. A small power penalty of 0.7 dB is observed compared to the back-to-back measurement.

  15. An uncertainty budget for VHF and UHF reflectometers

    NASA Astrophysics Data System (ADS)

    Ridler, N. M.; Medley, C. J.

    1992-05-01

    Details of the derivation of an uncertainty budget for one port immittance or complex voltage reflection coefficient measuring instruments, operating at VHF and UHF in the 14 mm 50 ohm coaxial line size, are reported. The principles of the uncertainty budget are given along with experimental results obtained using six ports and a network analyzer as the measuring instruments. Details of the types of calibration for which the uncertainty budget is suitable are reported. Various aspects of the uncertainty budget are considered and general principles and treatment of the type A and type B contributions are discussed. Experimental results obtained using the uncertainty budget are given. A summary of uncertainties for the six ports and HP8753B automatic network analyzer are also given.

  16. An accurate automated technique for quasi-optics measurement of the microwave diagnostics for fusion plasma

    NASA Astrophysics Data System (ADS)

    Hu, Jianqiang; Liu, Ahdi; Zhou, Chu; Zhang, Xiaohui; Wang, Mingyuan; Zhang, Jin; Feng, Xi; Li, Hong; Xie, Jinlin; Liu, Wandong; Yu, Changxuan

    2017-08-01

    A new integrated technique for fast and accurate measurement of the quasi-optics, especially for the microwave/millimeter wave diagnostic systems of fusion plasma, has been developed. Using the LabVIEW-based comprehensive scanning system, we can realize not only automatic but also fast and accurate measurement, which will help to eliminate the effects of temperature drift and standing wave/multi-reflection. With the Matlab-based asymmetric two-dimensional Gaussian fitting method, all the desired parameters of the microwave beam can be obtained. This technique can be used in the design and testing of microwave diagnostic systems such as reflectometers and the electron cyclotron emission imaging diagnostic systems of the Experimental Advanced Superconducting Tokamak.

  17. Grazing incidence reflection coefficients of rhodium, osmium, platinum, and gold from 50 to 300 A

    NASA Technical Reports Server (NTRS)

    Hettrick, M. C.; Edelstein, J.; Flint, S. A.

    1985-01-01

    Reflectance measurements were made of several metals illuminated from various angles with light at 14 wavelengths in the interval 46.5-283 A. The metals, Rh, Os, Pt and Au were deposited as 125 A films on a binding substrate through electron beam epitaxy. Measurements were made with a grazing incidence monochromator and a reflectometer. The data generally showed lowered reflectance with increasing angles of illumination and shorter wavelengths. The reflectance peak, however, was located at wavelengths of 100-160 A, particularly at large grazing incidences. The wavelengths correspond with the 5p to epsilon-d transition in all of the elements. Rh displayed the highest overall reflectance, and both Rh and Os were more efficient than Au or Pt.

  18. High-resolution differential mode delay measurement for a multimode optical fiber using a modified optical frequency domain reflectometer.

    PubMed

    Ahn, T-J; Kim, D

    2005-10-03

    A novel differential mode delay (DMD) measurement technique for a multimode optical fiber based on optical frequency domain reflectometry (OFDR) has been proposed. We have obtained a high-resolution DMD value of 0.054 ps/m for a commercial multimode optical fiber with length of 50 m by using a modified OFDR in a Mach-Zehnder interferometer structure with a tunable external cavity laser and a Mach-Zehnder interferometer instead of Michelson interferometer. We have also compared the OFDR measurement results with those obtained using a traditional time-domain measurement method. DMD resolution with our proposed OFDR technique is more than an order of magnitude better than a result obtainable with a conventional time-domain method.

  19. Several key issues on using 137Cs method for soil erosion estimation

    USDA-ARS?s Scientific Manuscript database

    This work was to examine several key issues of using the cesium-137 method to estimate soil erosion rates in order to improve and standardize the method. Based on the comprehensive review and synthesis of a large body of published literature and the author’s extensive research experience, several k...

  20. Teacher-Student Sexual Relations: Key Risks and Ethical Issues

    ERIC Educational Resources Information Center

    Sikes, Pat

    2010-01-01

    Researching actual or purported sexual contact between teachers and students raises many difficult ethical issues, questions and dilemmas, which may help to explain why few have ventured into the field. This experientially based paper addresses key problem areas under the headings of: the ethics of researching a sensitive taboo topic; the ethics…

  1. Key Questions on the Obama Administration's 2014 Education Budget Request. Issue Brief

    ERIC Educational Resources Information Center

    New America Foundation, 2013

    2013-01-01

    President Obama sent his fiscal year 2014 budget request to Congress on April 10, 2013. The New America Foundation's Education Policy Program released this subsequent issue brief, "Key Questions on the Obama Administration's 2014 Budget Request." Obama's budget request totals $71.2 billion in appropriations funding for the U.S.…

  2. Mixed Methods Research: What Are the Key Issues to Consider?

    ERIC Educational Resources Information Center

    Ghosh, Rajashi

    2016-01-01

    Mixed methods research (MMR) is increasingly becoming a popular methodological approach in several fields due to the promise it holds for comprehensive understanding of complex problems being researched. However, researchers interested in MMR often lack reference to a guide that can explain the key issues pertaining to the paradigm wars…

  3. Social Work Practice with Latinos: Key Issues for Social Workers

    ERIC Educational Resources Information Center

    Furman, Rich; Negi, Nalini Junko; Iwamoto, Derek Kenji; Rowan, Diana; Shukraft, Allison; Gragg, Jennifer

    2009-01-01

    The Latino population is the fastest growing group in the United States; thus, it is imperative that social workers and other mental health practitioners be knowledgeable about the current literature on how to effectively serve this population. This article elucidates key issues and knowledge, such as immigration and migration concerns; discusses…

  4. Building and Strengthening Policy Research Capacity: Key Issues in Canadian Higher Education

    ERIC Educational Resources Information Center

    Jones, Glen A.

    2014-01-01

    Given the importance of higher education in social and economic development, governments need to build a strong higher education data and policy research infrastructure to support informed decision-making, provide policy advice, and offer a critical assessment of key trends and issues. The author discusses the decline of higher education policy…

  5. Key Issues in Sex Education: Reflecting on Teaching, Learning and Assessment

    ERIC Educational Resources Information Center

    Oerton, Sarah; Bowen, Helen

    2014-01-01

    Drawing upon critical reflections of staff and student experiences of teaching, learning and assessment on an undergraduate module entitled Key Issues in Sex Education, we discuss the strategies used to engage students in debates around sex and relationships education (SRE). To date, there is little research which evaluates how formal assessments…

  6. Assuring Quality in Online Course Delivery

    ERIC Educational Resources Information Center

    Matuga, Julia M.; Wooldridge, Deborah G.; Poirier, Sandra

    2011-01-01

    This paper examines the critical issue of assuring quality online course delivery by examining four key components of online teaching and learning. The topic of course delivery is viewed as a cultural issue that permeates processes from the design of an online course to its evaluation. First, the authors examine and review key components of and…

  7. Progress in renewable energy.

    PubMed

    Gross, Robert; Leach, Matthew; Bauen, Ausilio

    2003-04-01

    This paper provides an overview of some of the key technological and market developments for leading renewable energy technologies--wind, wave and tidal, photovoltaics (PV) and biomass energy. Market growth, innovation and policy are closely interrelated in the development of renewables and the key issues in each area are explored for each of the main types of renewable energy technology. This enables the prospects for future development and cost reduction to be considered in detail. Key issues for policy are outlined. Copyright 2002 Elsevier Science Ltd.

  8. EPA's Reanalysis of Key Issues Related to Dioxin Toxicity and Response to NAS Comments (Volume 1) (Interagency Science Discussion Draft)

    EPA Science Inventory

    EPA is releasing the draft report, EPA's Reanalysis of Key Issues Related to Dioxin Toxicity and Response to NAS Comments (Volume 1), that was distributed to Federal agencies and White House Offices for comment during the Science Discussion step of the Training: Who Needs It? Research Report 1995. Key Issues for Providers.

    ERIC Educational Resources Information Center

    Hotel and Catering Training Co., London (England).

    Aimed at all those involved in the supply of training and vocational education for the hospitality industry, this report summarizes findings of the research report, "Training Who Needs It?" It draws out and explores in more detail key issues relating to the provision of training, support, and related initiatives for the industry. Section…

  9. A Case Study of Issues of Strategy Implementation in Internationalization of Higher Education

    ERIC Educational Resources Information Center

    Jiang, Nan; Carpenter, Victoria

    2013-01-01

    Purpose: The purpose of this research is to identify and critically evaluate key issues faced by an institution in the quest to implement higher education internationalization. Design/methodology/approach: A qualitative research is conducted in a post-1992 UK university. A total of 20 interviewees from three key departments participated in this…

  10. Eight Key Issues for the White House Conference on Library and Information Services.

    ERIC Educational Resources Information Center

    American Society for Information Science, Washington, DC.

    Presented as a public service in anticipation of the October 1979 White House Conference on Library and Information Services, the eight papers in this booklet call attention to the key issues which the American Society for Information Science (ASIS) believes have developed from proliferating information and for technological advances. Each of the…

  11. EPA's Reanalysis of Key Issues Related to Dioxin Toxicity and Response to NAS Comments (External Review Draft)

    EPA Science Inventory

  1. A Phenomenological Reinterpretation of Horner's Fear of Success in Terms of Social Class

    ERIC Educational Resources Information Center

    Ivers, Jo-Hanna; Downes, P.

    2012-01-01

    The current study developed the concept of fear of success that was originally examined by Martina Horner (1970; "Journal of Social Issues", 28(2), 157-175, 1972). The key dimension in Horner's (1970; "Journal of Social Issues", 28(2), 157-175, 1972) studies was gender. The key dimension in the current study was social class. It was hypothesised…

  2. Identification of Key Issues in Adopting a Web 2.0 E-Portfolio Strategy

    ERIC Educational Resources Information Center

    McKenna, Gary F.; Stansfield, Mark H.

    2013-01-01

    The purpose of the paper is to identify key issues relating to best practice and sustainability in Web 2.0 as an e-Learning strategy for supporting e-portfolios in Higher Education. A practical guidelines framework was developed for best practices, which can be justified by the lack of available frameworks in the e-Learning literature. A…

  3. Strategic management and organizational behavior in dental education: reflections on key issues in an environment of change.

    PubMed

    Dunning, David G; Durham, Timothy M; Lange, Brian M; Aksu, Mert N

    2009-06-01

    With issues such as shrinking revenue, access to care, faculty workloads, and graying faculty, dental schools are faced with difficult challenges that fall to dental school deans to manage. Do dental school deans have the organizational skill sets and ethical frameworks necessary to address the challenges now facing dental schools? The purpose of this article is to pose questions and suggestions regarding some of the key issues in dental colleges today and to stimulate discussion in the dental community about needed changes in dental education.

  4. Information for Government Agencies about Specific Environmental Health Issues in Child-Care Settings

    EPA Pesticide Factsheets

    research on child care environmental health issues, identify key state and regional healthy child care organizations for partnerships, and see how other states are addressing child care environmental health issues.

  5. Dental Public Health In Action: Putting Oral Health on the Local Public Health Agenda.

    PubMed

    Walker, I F; Eapen-Simon, S; Gibson, S

    2018-04-18

    Oral health is a key public health issue across England. In Wakefield in the north of England, local data suggested the oral health of local children was significantly worse than the national average. This paper describes the work undertaken by Wakefield Council to strategically address this issue. A structured process was adopted. Key lessons include; having senior ownership from the Director of Public Health, partnership working across all key stakeholders, utilising dental public health expertise from Public Health England and the use of extensive engagement with stakeholders. Through this work, oral health is now identified with greater importance in Wakefield as a public health issue. Actions are now strategically co-ordinated across stakeholders to improve oral health in local children. Copyright© 2018 Dennis Barber Ltd.

  6. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sun, X.; Yao, C.

    A prototype dual-blade stripline kicker for the APS multi-bend achromat (MBA) upgrade has been designed and developed. It was optimized with 3D CST Microwave Studio. The high voltage (HV) feedthrough and air-side connector were designed and optimized. Electromagnetic fields along the beam path, the deflecting angle, the high electric fields and their locations were calculated with 15kV differential pulse voltage applied to the kicker blades through the feedthroughs. Beam impedance and the power dissipation on different parts of the kicker and external loads were studied for a 48-bunch fill pattern. Our results show that the prototype kicker with its HVmore » feedthroughs meets the specified requirements. The results of TDR (time-domain reflectometer) test, high voltage pulse test and beam test of the prototype kicker assembly agreed with the simulations.« less

  7. Magnetic Fields of Lunar Impact Basins and Their Use in Constraining the Impact Process

    NASA Astrophysics Data System (ADS)

    Halekas, J. S.; Lin, R. P.

    2003-01-01

    Measurements by the Magnetometer/Electron Reflectometer instrument on the Lunar Prospector spacecraft, which completed its mapping mission in 1999, have been used to construct the first completely global maps of lunar crustal magnetic fields. Now, for the first time, we have a data set with global coverage and a sensitivity and resolution which allow us to investigate the magnetic fields of lunar impact basins and craters. As on the Earth, impact sites have a variety of magnetic signatures associated with them, ranging from nearly complete demagnetization to strong central magnetic anomalies. Observations of the magnetic fields of terrestrial basins have been used to make inferences about the impact process, and we wish to show that lunar observations can also provide valuable constraints.

  8. Calibration Procedure for Measuring S-Parameters in Balun Applications on 150-ohm High-Speed Cables

    NASA Technical Reports Server (NTRS)

    Theofylaktos, Onoufrios; Warner, Joseph D.

    2012-01-01

    In the radiofrequency (RF) world, in order to characterize cables that do not conform to the typical 50-omega impedance, a time domain reflectometer (TDR) would probably be the simplest and quickest tool to attain this goal. In the real world, not every engineer has a TDR at their disposal; however, they most likely have a network analyzer available. Given a generic 50-omega vector network analyzer (VNA), we would like to make S-parameter measurements for non-50-omega devices (DUTs). For that, we utilize RF balanced/unbalanced transformers (called baluns for short), which are primarily used to match the impedance between the two VNA ports and the DUT's input and output ports, for the two-port S-parameter measurements.

  9. Experiment and application of soft x-ray grazing incidence optical scattering phenomena

    NASA Astrophysics Data System (ADS)

    Chen, Shuyan; Li, Cheng; Zhang, Yang; Su, Liping; Geng, Tao; Li, Kun

    2017-08-01

    For short wavelength imaging systems,surface scattering effects is one of important factors degrading imaging performance. Study of non-intuitive surface scatter effects resulting from practical optical fabrication tolerances is a necessary work for optical performance evaluation of high resolution short wavelength imaging systems. In this paper, Soft X-ray optical scattering distribution is measured by a soft X-ray reflectometer installed by my lab, for different sample mirrors、wavelength and grazing angle. Then aim at space solar telescope, combining these scattered light distributions, and surface scattering numerical model of grazing incidence imaging system, PSF and encircled energy of optical system of space solar telescope are computed. We can conclude that surface scattering severely degrade imaging performance of grazing incidence systems through analysis and computation.

  10. Development of a distributed polarization-OTDR to measure two vibrations with the same frequency

    NASA Astrophysics Data System (ADS)

    Pan, Yun; Wang, Feng; Wang, Xiangchuan; Zhang, Mingjiang; Zhou, Ling; Sun, Zhenqing; Zhang, Xuping

    2015-08-01

    A polarization optical time-domain reflectometer (POTDR) can distributedly measure the vibration of fiber by detecting the vibration induced polarization variation only with a polarization analyzer. It has great potential in the monitoring of the border intrusion, structural healthy, anti-stealing of pipeline and so on, because of its simple configuration, fast response speed and distributed measuring ability. However, it is difficult to distinguish two vibrations with the same frequency for POTDR because the signal induced by the first vibration would bury the other vibration induced signal. This paper proposes a simple method to resolve this problem in POTDR by analyzing the phase of the vibration induced signal. The effectiveness of this method in distinguishing two vibrations with the same frequency for POTDR is proved by simulation.

  11. Development of a polarized neutron beam line at Algerian research reactors using McStas software

    NASA Astrophysics Data System (ADS)

    Makhloufi, M.; Salah, H.

    2017-02-01

    Unpolarized instrumentation has long been studied and designed using McStas simulation tool. But, only recently new models were developed for McStas to simulate polarized neutron scattering instruments. In the present contribution, we used McStas software to design a polarized neutron beam line, taking advantage of the available spectrometers reflectometer and diffractometer in Algeria. Both thermal and cold neutron was considered. The polarization was made by two types of supermirrors polarizers FeSi and CoCu provided by the HZB institute. For sake of performance and comparison, the polarizers were characterized and their characteristics reproduced. The simulated instruments are reported. Flipper and electromagnets for guide field are developed. Further developments including analyzers and upgrading of the existing spectrometers are underway.

  12. Key issues in the quality assurance of the One Number Census.

    PubMed

    Diamond, Ian; Abbott, Owen; Jackson, Neil

    2003-01-01

    As part of the 2001 Census, the One Number Census project estimated and adjusted the Census database for underenumeration. As a result of the highly innovative One Number Census and the Quality Assurance process it encompassed, it was also ensured that robust results could be obtained for each local authority area. This article examines some of the issues and analyses that were undertaken as part of that assessment of the 2001 Census population counts for England and Wales. The article firstly highlights the key issues surrounding the implementation of the 2001 Census fieldwork. The article then explores the 2001 Census results through a series of demographic analyses to illustrate the sorts of issues investigated during the One Number Census Quality Assurance process itself. These analyses look at the patterns contained within the results, and comparisons with key alternative sources of population counts. Overall, these in-depth analyses and investigations provide further credence to the plausibility of the One Number Census results.

  13. Towards Providing Culturally Aware Nutritional Care for Transgender People: Key Issues and Considerations.

    PubMed

    Fergusson, Pamela; Greenspan, Nicole; Maitland, Lukas; Huberdeau, Rémy

    2018-06-01

    Transgender people are an important group for whom access to healthcare is often problematic. Dietitians need to be aware of key issues in transgender health to provide culturally competent clinical nutritional care. This article serves as a primer, clarifying key terms and concepts, exploring the impact of stigma and discrimination on health and nutrition for people from transgender communities, and offering practical advice for nutritional and other related issues. Education for dietitians both pre- and postqualification is an important part of improving care and building skills and awareness of cultural humility. Transgender people may be at increased nutritional risk due to increased risk of cardiovascular disease, HIV, body image issues, and food insecurity. This risk profile, along with the history of trauma both outside and related to the medical community means that there is an urgent need for dietitians to develop practice tools for assessment, care, and referral to improve the nutritional status and well-being of this client group.

  14. Arctic Freshwater Synthesis: Summary of key emerging issues

    NASA Astrophysics Data System (ADS)

    Prowse, T.; Bring, A.; Mârd, J.; Carmack, E.; Holland, M.; Instanes, A.; Vihma, T.; Wrona, F. J.

    2015-10-01

    In response to a joint request from the World Climate Research Program's Climate and Cryosphere Project, the International Arctic Science Committee, and the Arctic Council's Arctic Monitoring and Assessment Program an updated scientific assessment has been conducted of the Arctic Freshwater System (AFS), entitled the Arctic Freshwater Synthesis (AFSΣ). The major reason behind the joint request was an increasing concern that changes to the AFS have produced, and could produce even greater, changes to biogeophysical and socioeconomic systems of special importance to northern residents and also produce extra-Arctic climatic effects that will have global consequences. The AFSΣ was structured around six key thematic areas: atmosphere, oceans, terrestrial hydrology, terrestrial ecology, resources, and modeling, the review of each coauthored by an international group of scientists and published as separate manuscripts in this special issue of Journal of Geophysical Research-Biogeosciences. This AFSΣ summary manuscript reviews key issues that emerged during the conduct of the synthesis, especially those that are cross-thematic in nature, and identifies future research required to address such issues.

  15. Security on Cloud Revocation Authority using Identity Based Encryption

    NASA Astrophysics Data System (ADS)

    Rajaprabha, M. N.

    2017-11-01

    As due to the era of cloud computing most of the people are saving there documents, files and other things on cloud spaces. Due to this security over the cloud is also important because all the confidential things are there on the cloud. So to overcome private key infrastructure (PKI) issues some revocable Identity Based Encryption (IBE) techniques are introduced which eliminates the demand of PKI. The technique introduced is key update cloud service provider which is having two issues in it and they are computation and communication cost is high and second one is scalability issue. So to overcome this problem we come along with the system in which the Cloud Revocation Authority (CRA) is there for the security which will only hold the secret key for each user. And the secret key was send with the help of advanced encryption standard security. The key is encrypted and send to the CRA for giving the authentication to the person who wants to share the data or files or for the communication purpose. Through that key only the other user will able to access that file and if the user apply some invalid key on the particular file than the information of that user and file is send to the administrator and administrator is having rights to block that person of black list that person to use the system services.

  16. Facilities removal working group

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    This working group`s first objective is to identify major economic, technical, and regulatory constraints on operator practices and decisions relevant to offshore facilities removal. Then, the group will try to make recommendations as to regulatory and policy adjustments, additional research, or process improvements and/or technological advances, that may be needed to improve the efficiency and effectiveness of the removal process. The working group will focus primarily on issues dealing with Gulf of Mexico platform abandonments. In order to make the working group sessions as productive as possible, the Facilities Removal Working Group will focus on three topics that address amore » majority of the concerns and/or constraints relevant to facilities removal. The three areas are: (1) Explosive Severing and its Impact on Marine Life, (2) Pile and Conductor Severing, and (3) Deep Water Abandonments This paper will outline the current state of practice in the offshore industry, identifying current regulations and specific issues encountered when addressing each of the three main topics above. The intent of the paper is to highlight potential issues for panel discussion, not to provide a detailed review of all data relevant to the topic. Before each panel discussion, key speakers will review data and information to facilitate development and discussion of the main issues of each topic. Please refer to the attached agenda for the workshop format, key speakers, presentation topics, and panel participants. The goal of the panel discussions is to identify key issues for each of the three topics above. The working group will also make recommendations on how to proceed on these key issues.« less

  17. Work Keys USA.

    ERIC Educational Resources Information Center

    Work Keys USA, 1998

    1998-01-01

    "Work Keys" is a comprehensive program for assessing and teaching workplace skills. This serial "special issue" features 18 first-hand reports on Work Keys projects in action in states across North America. They show how the Work Keys is helping businesses and educators solve the challenge of building a world-class work force.…

  18. Key issues and technical route of cyber physical distribution system

    NASA Astrophysics Data System (ADS)

    Zheng, P. X.; Chen, B.; Zheng, L. J.; Zhang, G. L.; Fan, Y. L.; Pei, T.

    2017-01-01

    Relying on the National High Technology Research and Development Program, this paper introduced the key issues in Cyber Physical Distribution System (CPDS), mainly includes: composite modelling method and interaction mechanism, system planning method, security defence technology, distributed control theory. Then on this basis, the corresponding technical route is proposed, and a more detailed research framework along with main schemes to be adopted is also presented.

  19. Sexual Health Services for Young People in a Rural Area of Northern Ireland: A Study of the Key Issues for Those Who Provide Them

    ERIC Educational Resources Information Center

    McCann, Lyndsey; Donnelly, Lyn; Quinn, Phelim; McAnerney, Rosemary

    2008-01-01

    Objective: To identify the key issues for service providers in delivering high quality sexual health services, responsive to the needs of young people, in a rural area of Northern Ireland. Design: A triangulation survey approach using questionnaires, in-depth interviews and focus groups was undertaken with a range of organizations and…

  20. A Discussion with Sandy O'Sullivan about Key Issues for the Australian Indigenous Studies Learning and Teaching Network

    ERIC Educational Resources Information Center

    Barney, Katelyn

    2014-01-01

    This article takes the form of an interview with Sandy O'Sullivan, who is a partner on the Australian Indigenous Studies Learning and Teaching Network, about key issues that have arisen through Network discussions. She is a Wiradjuri woman and a Senior Aboriginal researcher at the Batchelor Institute of Indigenous Tertiary Education. O'Sullivan…

  1. 82 Key Statistics on Work and Family Issues. The National Report on Work & Family. Special Report #9.

    ERIC Educational Resources Information Center

    Bureau of National Affairs, Inc., Washington, DC.

    This report was prepared because of the growing national interest in the questions of work and family dynamics. It puts together 82 key statistics on work and family issues in four major areas: child care, parental leave, alternative work schedules, and elder care. In addition, a chapter of miscellaneous statistics covers areas such as the…

  2. Wildfire in the United Kingdom: status and key issues

    Treesearch

    Julia McMorrow

    2011-01-01

    This paper reviews the status of wildfire risk in the United Kingdom and examines some of the key issues in U.K. wildfire management. Wildfires challenge the resources of U.K. Fire and Rescue Services (FRSs), especially in dry years, yet FRSs are poorly equipped and trained to deal with wildfire. A brief geography of U.K. wildfires is presented using fire statistics...

  3. Executive Summary of the 1999 External Environmental Scan and the Internal Environmental Scan Report Card: Key Issues for Planning.

    ERIC Educational Resources Information Center

    Beachler, Judith

    This document is the second in a series of summary reports outlining Key Issues for Planning useful to staff throughout the Los Rios Community College District (CA) for the 1999-2000 academic year and beyond. The 1999 Environmental Scan of Greater Sacramento provides a comprehensive look at the external environment. It outlines changes in the…

  4. Questioning Inclusion: The Education of Roma/Traveller Students and Young People in Europe and England--A Critical Examination

    ERIC Educational Resources Information Center

    Themelis, Spyros

    2009-01-01

    This article deals with issues pertinent to the "inclusion" of Roma/Traveller children and young people in Europe and, in particular, England. It discusses some key issues that pertain to the inclusion of Roma/Traveller groups in society and it critically presents some key policies that have been advanced to tackle educational and social…

  5. Continuing Education of the Professions: Issues, Ethics, and Conflicts

    ERIC Educational Resources Information Center

    Frandson, Phillip E.

    1975-01-01

    Relicensure has emerged as one of today's key issues in the continuing education of the professional. The conflict is clear: Who shall be controlling force? A grid involving the six issues focuses on the constituencies who seek to control these issues. The medical profession is used as an example. (BP)

  6. California Tribal Nations Technical Water Research

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ben, C; Coty, J

    2005-08-15

    This research focused on identifying the key technical water issues of federally recognized California Native American tribes, the context within which these water issues arise for the tribes, and an appropriate format for potentially opening further dialogue on water research issues between the tribes and Lawrence Livermore National Laboratory (LLNL) scientists. At LLNL, a Water Quality and Resource Management Issues Workshop held in January of 2003 resulted in multiple recommendations, one proposing a LLNL dialogue with California tribes to further inform LLNL's prioritization of water issues based on identified needs across national sectors. The focus of this aforementioned Water Qualitymore » and Resource Management Issues Workshop was to identify national and international priority water research issues with which LLNL may align their research efforts and contribute to resolving these needs. LLNL staff researched various sectors to delineate the key water issues associated with each. This preliminary water issue research included diverse entities such as international water agencies, federal and state agencies, industry, non-governmental agencies, and private organizations. The key (identified) water issues across these sectors were presented to workshop attendees and used during workshop debates and sessions. However, the key water issues of federally recognized Native American tribes remained less understood, resulting in a workshop proposal for additional research and LLNL potentially hosting a dialog with representatives of these tribes. Federally recognized Native American tribes have a unique government-to-government relationship with the United States (U.S.) government, in contrast to other sectors researched for the workshop. Within the U.S., the number of federally recognized tribes currently stands at 562 and, in addition to this large number of tribes, much diversity across these tribes exists. For the purposes of this preliminary research and report, it was necessary to confine the analysis to a smaller geographic area, yet still represent the diversity of tribes and context within which tribal water issues arise. The state of California provides this opportunity. California has 106 federally recognized tribes. California is diverse in its geography, environment, demographics, and economic bases; California tribes demonstrate similar diversity. Additionally, no central repository of national or state tribal water issues exists and information must be aggregated, in general, tribe by tribe. This presents research challenges and, for this report, these were overcome by developing a method to essentially ''sub-sample'' the 106 federally recognized tribes in the state, while making every effort to maintain a sub-sample that broadly represents all of the 106 tribes. n an effort to develop an equitable and appropriate method with which to identify this set of representative tribes, multiple entities were contacted for guidance. Consultation with the Bureau of Indian Affairs (BIA), Environmental Protection Agency (EPA), Indian Health Services (IHS), U.S. Department of Agriculture (USDA), Bureau of Reclamation (BOR) and Tribal Environmental Directors, provided key information and recommendations to guide the research process. It is hoped that an appropriate representation of the diversity of tribes across the state has been achieved; this includes an adequate representation of similarities and differences between Californian tribes on key water research issues (and the same between regions). This research occurred over a limited time period (i.e., three months) and given a general concern that this may not be sufficient, any information and conclusions in this report should be viewed with this in mind. Finally, it is hoped that this research allows for an (enhanced) informed capacity to better propose further dialog between tribes and LLNL to continue to exchange water research perspectives and define potential research collaborations.« less

  7. International and domestic regulator issues facing the Canadian MSAT system

    NASA Technical Reports Server (NTRS)

    Bahman, Azarbar; Langlois, Jacques R.; Frank, Christopher J.

    1988-01-01

    International and domestic regulatory issues which affect the implementation of a mobile satellite system (MSAT) over North America are addressed. WARC-MOB-87, MSAT frequency co-ordination, frequency sharing and key Canadian domestic issues are discussed.

  8. Special Section: Extension in a Global Context.

    ERIC Educational Resources Information Center

    Rosson, C. Parr, III; And Others

    1991-01-01

    "International Programming Issues for Extension Education" (Rosson, Sanders) describes a survey of extension personnel identifying global competition and agriculture as a key issue. "Expanding Our Horizons Internationally" (Richardson, Woods) discusses North Carolina Extension's staff development on global issues. In…

  9. ERCMExpress. Volume 3, Issue 4

    ERIC Educational Resources Information Center

    Taymans, Mary Frances; McDonald, Dale

    2007-01-01

    The Emergency Response and Crisis Management (ERCM) Technical Assistance Center's "ERCMExpress" is a newsletter that provides comprehensive information on key issues in school emergency management. This issue, entitled "Emergency Management Opportunities and Challenges for Non-Public Schools," examines integrating non-public…

  10. Caregiving and, Decision-Making For Seniors: How You Can Help

    MedlinePlus

    ... Issue Past Issues Feature: Senior Living Caregiving and Decision-Making For Seniors: How You Can Help Past Issues / ... key resources and suggestions for effective care and decision-making for seniors. —The Editors To Find Out More ...

  11. Multisource data assimilation in a Richards equation-based integrated hydrological model: a real-world application to an experimental hillslope

    NASA Astrophysics Data System (ADS)

    Camporese, M.; Botto, A.

    2017-12-01

    Data assimilation is becoming increasingly popular in hydrological and earth system modeling, as it allows for direct integration of multisource observation data in modeling predictions and uncertainty reduction. For this reason, data assimilation has been recently the focus of much attention also for integrated surface-subsurface hydrological models, whereby multiple terrestrial compartments (e.g., snow cover, surface water, groundwater) are solved simultaneously, in an attempt to tackle environmental problems in a holistic approach. Recent examples include the joint assimilation of water table, soil moisture, and river discharge measurements in catchment models of coupled surface-subsurface flow using the ensemble Kalman filter (EnKF). Although the EnKF has been specifically developed to deal with nonlinear models, integrated hydrological models based on the Richards equation still represent a challenge, due to strong nonlinearities that may significantly affect the filter performance. Thus, more studies are needed to investigate the capabilities of EnKF to correct the system state and identify parameters in cases where the unsaturated zone dynamics are dominant. Here, the model CATHY (CATchment HYdrology) is applied to reproduce the hydrological dynamics observed in an experimental hillslope, equipped with tensiometers, water content reflectometer probes, and tipping bucket flow gages to monitor the hillslope response to a series of artificial rainfall events. We assimilate pressure head, soil moisture, and subsurface outflow with EnKF in a number of assimilation scenarios and discuss the challenges, issues, and tradeoffs arising from the assimilation of multisource data in a real-world test case, with particular focus on the capability of DA to update the subsurface parameters.

  12. Assessing Campus Climates for Lesbian, Gay, Bisexual and Transgender (LGBT) Students: Methodological and Political Issues

    ERIC Educational Resources Information Center

    Brown, Robert D.; Gortmaker, Valerie J.

    2009-01-01

    Methodological and political issues arise during the designing, conducting, and reporting of campus-climate studies for LGBT students. These issues interact; making a decision about a methodological issue (e.g., sample size) has an impact on a political issue (e.g., how well the findings will be received). Ten key questions that must be addressed…

  13. Current Issues: Critical Issues Confronting the Nation and the World. 1997 Edition [and] Teacher's Guide.

    ERIC Educational Resources Information Center

    Close Up Foundation, Arlington, VA.

    This student text and teacher's guide feature current events and policy issues that are in discussion today. The books offer background on 20 important domestic and foreign policy issues and present arguments from both sides of key issues. The books are divided into three sections. Section 1, "The Federal Government," contains: (1) "The Clinton…

  14. Authentication and Encryption Using Modified Elliptic Curve Cryptography with Particle Swarm Optimization and Cuckoo Search Algorithm

    NASA Astrophysics Data System (ADS)

    Kota, Sujatha; Padmanabhuni, Venkata Nageswara Rao; Budda, Kishor; K, Sruthi

    2018-05-01

    Elliptic Curve Cryptography (ECC) uses two keys private key and public key and is considered as a public key cryptographic algorithm that is used for both authentication of a person and confidentiality of data. Either one of the keys is used in encryption and other in decryption depending on usage. Private key is used in encryption by the user and public key is used to identify user in the case of authentication. Similarly, the sender encrypts with the private key and the public key is used to decrypt the message in case of confidentiality. Choosing the private key is always an issue in all public key Cryptographic Algorithms such as RSA, ECC. If tiny values are chosen in random the security of the complete algorithm becomes an issue. Since the Public key is computed based on the Private Key, if they are not chosen optimally they generate infinity values. The proposed Modified Elliptic Curve Cryptography uses selection in either of the choices; the first option is by using Particle Swarm Optimization and the second option is by using Cuckoo Search Algorithm for randomly choosing the values. The proposed algorithms are developed and tested using sample database and both are found to be secured and reliable. The test results prove that the private key is chosen optimally not repetitive or tiny and the computations in public key will not reach infinity.

  15. Issues in Distance Education: A Primer for Higher Education Decision Makers

    ERIC Educational Resources Information Center

    Beaudoin, Michael

    2016-01-01

    This chapter presents an overview of current issues related to distance learning in higher education. It identifies central questions, issues, challenges, and opportunities that must be addressed by decision makers, as well as key attributes of effective leaders.

  16. An impetus to move the field forward: a look at child and adolescent mental health services participants' views of the prospects for change.

    PubMed

    Haynes, Katherine Taylor

    2010-03-01

    In September 2009 key stakeholders convened for the invitation-only Child and Adolescent Mental Health Services (CAMHS): Issues and Solutions conference. This paper provides a brief synopsis of the key high points and issues in children's mental health (CMH) and describes the process by which participants collectively brainstormed the priorities and distilled the four key foci for the new action agenda, and summarizes the key outcomes. In addition, this paper offers participants' perspectives on the conference. Based on observation notes and post-conference qualitative interviews, this paper reports conference participants' feedback on the event, their views on the prospects for change generated by the conference and suggestions for follow-up.

  17. Problems with provision: barriers to drinking water quality and public health in rural Tasmania, Australia.

    PubMed

    Whelan, Jessica J; Willis, Karen

    2007-01-01

    Access to safe drinking water is essential to human life and wellbeing, and is a key public health issue. However, many communities in rural and regional parts of Australia are unable to access drinking water that meets national standards for protecting human health. The aim of this research was to identify the key issues in and barriers to the provision and management of safe drinking water in rural Tasmania, Australia. Semi-structured interviews were conducted with key local government employees and public health officials responsible for management of drinking water in rural Tasmania. Participants were asked about their core public health duties, regulatory responsibilities, perceptions and management of risk, as well as the key barriers that may be affecting the provision of safe drinking water. This research highlights the effect of rural locality on management and safety of fresh water in protecting public health. The key issues contributing to problems with drinking water provision and quality identified by participants included: poor and inadequate water supply infrastructure; lack of resources and staffing; inadequate catchment monitoring; and the effect of competing land uses, such as forestry, on water supply quality. This research raises issues of inequity in the provision of safe drinking water in rural communities. It highlights not only the increasing need for greater funding by state and commonwealth government for basic services such as drinking water, but also the importance of an holistic and integrated approach to managing drinking water resources in rural Tasmania.

  18. 101 Key Statistics on Work and Family for the 1990s. The BNA Special Report Series on Work and Family: Special Report No. 21.

    ERIC Educational Resources Information Center

    Bureau of National Affairs, Inc., Washington, DC.

    This special report updates a September, 1988 Bureau of National Affairs (BNA) special report, "82 Key Statistics on Work and Family Issues," by presenting 101 new statistics on work and family concerns. Data concern: (1) child care; (2) parental leave; (3) elder care; (4) flexible work schedules; and (5) miscellaneous issues, such as…

  19. Mexican Americans' Educational Barriers and Progress: Is the Magic Key within Reach? PERSPECTIVAS: Issues in Higher Education Policy and Practice. Issue No. 5, Spring 2016

    ERIC Educational Resources Information Center

    Zambrana, Ruth Enid; Hurtado, Sylvia

    2016-01-01

    This policy brief is based on the edited book "The Magic Key: The Educational Journey of Mexican Americans from K-12 to College and Beyond" (Zambrana & Hurtado, 2015a), which focuses on the experiences of Mexican Americans in education. Drawing from an interdisciplinary corpus of work, the authors move beyond the rhetoric of progress…

  20. The Future We Want: Key Issues on Sustainable Development in Higher Education after Rio and the UN Decade of Education for Sustainable Development

    ERIC Educational Resources Information Center

    Leal Filho, Walter; Manolas, Evangelos; Pace, Paul

    2015-01-01

    Purpose: This paper aims to provide a description of the achievements of the United Nations (UN) Decade of Education for Sustainable Development (2005-2014) with a focus on higher education, and it describes some of the key issues which will guide sustainable development in the coming years. Design/methodology/approach: The paper initially…

  1. Who owns Australia's water--elements of an effective regulatory model.

    PubMed

    McKay, J

    2003-01-01

    This paper identifies and describes a number of global trends in regulatory theory and legal scholarship. It points out the huge level of complexity demanded by globalisation and the unfortunate complication of this is that there is legal indeterminacy. The legal indeterminacy springs from the desire to amend and alter existing models. That has been the thrust of the Council of Australian Governments changes to adapt and add huge amounts of complexity to a flawed system. This paper argues that an effective water regulatory model requires a fundamental re-examination of the concept of water ownership and a capturing by the State of the right to allocate rainfall. This foundation is effective and the way forward to deal with the key issues in this transition phase. The second key element to an effective regulatory model is the concept of performance-based assessment. This requires information and schemes to be set up to work out ways to monitor and evaluate the performance of the utility on selected criteria. For Australia at present there is a dire lack of agreed criteria on these key issues and these have the potential to pull apart the whole process. The key issues are indigenous rights, governance issues, public participation, alteration of pre-existing rights and incorporation of environmental requirements.

  2. NEP systems engineering efforts in FY-92: Plans and status

    NASA Technical Reports Server (NTRS)

    Doherty, Michael P.; Gilland, James H.

    1992-01-01

    A system engineering effort has been initiated by NASA in FY-92 to define, address, and resolve issues associated with the use of Nuclear Electric Propulsion (NEP) for megawatt (MW) space propulsion applications associated with the Space Exploration Initiative (SEI). It is intended that key technical issues will be addressed by activities conducted in the early years of a project in NEP, with the objective of resolving such issues. Also, in response to more recent programmatic direction, a concept definition activity for 100 kilowatt NEP is being initiated. This paper will present key issues associated with megawatt NEP, and the plans and status for their resolution, and present the scope and rationale for the 100 kilowatt concept definition activity.

  3. Instrumentation issues in implementation science.

    PubMed

    Martinez, Ruben G; Lewis, Cara C; Weiner, Bryan J

    2014-09-04

    Like many new fields, implementation science has become vulnerable to instrumentation issues that potentially threaten the strength of the developing knowledge base. For instance, many implementation studies report findings based on instruments that do not have established psychometric properties. This article aims to review six pressing instrumentation issues, discuss the impact of these issues on the field, and provide practical recommendations. This debate centers on the impact of the following instrumentation issues: use of frameworks, theories, and models; role of psychometric properties; use of 'home-grown' and adapted instruments; choosing the most appropriate evaluation method and approach; practicality; and need for decision-making tools. Practical recommendations include: use of consensus definitions for key implementation constructs; reporting standards (e.g., regarding psychometrics, instrument adaptation); when to use multiple forms of observation and mixed methods; and accessing instrument repositories and decision aid tools. This debate provides an overview of six key instrumentation issues and offers several courses of action to limit the impact of these issues on the field. With careful attention to these issues, the field of implementation science can potentially move forward at the rapid pace that is respectfully demanded by community stakeholders.

  4. Clinical Issues-October 2016.

    PubMed

    Wood, Amber

    2016-10-01

    Wearing nail polish Key words: nail, polish, UV-cured, gel nail, Shellac. Preventing dry skin Key words: dry skin, chapped, dermatitis, hand hygiene. Wearing rings Key words: ring, jewelry, wedding ring, band, hand hygiene. Copyright © 2016 AORN, Inc. Published by Elsevier Inc. All rights reserved.

  5. Key Cognitive Issues in the Design of Electronic Displays of Instrument Approach Procedure Charts

    DOT National Transportation Integrated Search

    1993-11-01

    This report provides a general introduction to the field of cognitive psychology and the application of well researched cognitive issues to the design of electronic instrument approach procedures (EIAP) displays. It presents 46 cognitive issues and 1...

  6. DOT's Budget: Safety, Management, and Other Issues Facing the Department in Fiscal Year 1998 and Beyond

    DOT National Transportation Integrated Search

    1997-03-06

    This testimony discusses key resource management issues and performance challenges facing the Department of Transportation in 1998 and beyond. 1. Increased safety and security concerns prompted by accidents and maintenance issues. 2. Important manage...

  7. CTE's Role in Urban Education. Issue Brief

    ERIC Educational Resources Information Center

    Association for Career and Technical Education (ACTE), 2012

    2012-01-01

    This Issue Brief explores the promising role that career and technical education programs play in addressing key student achievement issues facing urban schools. CTE programs engage urban students by providing rigorous and relevant coursework, fostering positive relationships, establishing clear pathways and connecting education and…

  8. Environmental Scanning and the Information Manager.

    ERIC Educational Resources Information Center

    Newsome, James; McInerney, Claire

    1990-01-01

    Discusses nine components of an environmental scanning model: selecting the scanning team; selecting resources to scan; choosing criteria for scanning; scanning the resources; identifying signals of new issues; selecting key events/issues; monitoring and analyzing events/issues; disseminating information; and deciding on appropriate organizational…

  9. Key Health Information Technologies and Related Issues for Iran: A Qualitative Study.

    PubMed

    Hemmat, Morteza; Ayatollahi, Haleh; Maleki, Mohammadreza; Saghafi, Fatemeh

    2018-01-01

    Planning for the future of Health Information Technology (HIT) requires applying a systematic approach when conducting foresight studies. The aim of this study was to identify key health information technologies and related issues for Iran until 2025. This was a qualitative study and the participants included experts and policy makers in the field of health information technology. In-depth semi-structured interviews were conducted and data were analyzed by using framework analysis and MAXQDA software. The findings revealed that the development of national health information network, electronic health records, patient health records, a cloud-based service center, interoperability standards, patient monitoring technologies, telehealth, mhealth, clinical decision support systems, health information technology and mhealth infrastructure were found to be the key technologies for the future. These technologies could influence the economic, organizational and individual levels. To achieve them, the economic and organizational obstacles need to be overcome. In this study, a number of key technologies and related issues were identified. This approach can help to focus on the most important technologies in the future and to priorities these technologies for better resource allocation and policy making.

  10. Key Issues and Policy Considerations in Promoting Lifelong Learning in Selected African Countries: Ethiopia, Kenya, Namibia, Rwanda and Tanzania. UIL Publication Series on Lifelong Learning Policies and Strategies. No. 1

    ERIC Educational Resources Information Center

    Walters, Shirley; Yang, Jim; Roslander, Peter

    2014-01-01

    This cross-national study focuses on key issues and policy considerations in promoting lifelong learning in Ethiopia, Kenya, Namibia, Rwanda, and Tanzania (the five African countries that took part in a pilot workshop on "Developing Capacity for Establishing Lifelong Learning Systems in UNESCO Member States: at the UNESCO Institute for…

  11. Starting a hospital-based home health agency: Part II--Key success factors.

    PubMed

    Montgomery, P

    1993-09-01

    In Part II of a three-part series, the financial, technological and legislative issues of a hospital-based home health-agency are discussed. Beginning a home healthcare service requires intensive research to answer key environmental and operational questions--need, competition, financial projections, initial start-up costs and the impact of delayed depreciation. Assessments involving technology, staffing, legislative and regulatory issues can help project service volume, productivity and cost-control.

  12. Key Issues in the Networking Field Today. Proceedings of the Library of Congress Network Advisory Committee Meeting (Washington, DC, May 6-8, 1985). Network Planning Paper No. 12.

    ERIC Educational Resources Information Center

    Library of Congress, Washington, DC. Network Development Office.

    The May 1985 program session of the Library of Congress Network Advisory Committee focused on the identification of key issues in the networking field. Presentations included discussions of major network developments in the last two decades, the changing network players, the impact of technology on networks, and library networks and the law. The…

  13. Quality assurance in transnational higher education: a case study of the tropEd network

    PubMed Central

    2013-01-01

    Introduction Transnational or cross-border higher education has rapidly expanded since the 1980s. Together with that expansion issues on quality assurance came to the forefront. This article aims to identify key issues regarding quality assurance of transnational higher education and discusses the quality assurance of the tropEd Network for International Health in Higher Education in relation to these key issues. Methods Literature review and review of documents. Results From the literature the following key issues regarding transnational quality assurance were identified and explored: comparability of quality assurance frameworks, true collaboration versus erosion of national education sovereignty, accreditation agencies and transparency. The tropEd network developed a transnational quality assurance framework for the network. The network accredits modules through a rigorous process which has been accepted by major stakeholders. This process was a participatory learning process and at the same time the process worked positive for the relations between the institutions. Discussion The development of the quality assurance framework and the process provides a potential example for others. PMID:23537108

  14. Measuring competition in health care markets.

    PubMed Central

    Baker, L C

    2001-01-01

    OBJECTIVE: Measuring competition is increasingly important for analysis of health care markets and policies. Measurement of competition in health care is made complex by the breadth of potential issues under study, by the lack of necessary data, and by rapid changes in health care financing and delivery. This study reviews key issues in the measurement of competition and is designed to familiarize researchers and policymakers interested in competition measurement, but not steeped in its practice, with key concepts, data sources, and ways of adapting measures to fit ongoing changes in health care markets. PRINCIPAL FINDINGS: Attention to several key issues will strengthen measurement. Important components of successful measurement are: careful identification of the products and market areas for study; selection of Herfindahl-Hirschman or other indices to fit the issues being considered; consideration of econometric problems, like endogeneity, with common measures; and attention to the ways that current marketplace changes, like growth in managed care, affect the performance of classic measures. Data needed for constructing measures are also frequently scarce, insufficient, or both. Measurement could be improved with access to better data. PMID:11327175

  15. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kaufmann, John R.; Hand, James R.; Halverson, Mark A.

    This report evaluates how and when to best integrate renewable energy requirements into building energy codes. The basic goals were to: (1) provide a rough guide of where we’re going and how to get there; (2) identify key issues that need to be considered, including a discussion of various options with pros and cons, to help inform code deliberations; and (3) to help foster alignment among energy code-development organizations. The authors researched current approaches nationally and internationally, conducted a survey of key stakeholders to solicit input on various approaches, and evaluated the key issues related to integration of renewable energymore » requirements and various options to address those issues. The report concludes with recommendations and a plan to engage stakeholders. This report does not evaluate whether the use of renewable energy should be required on buildings; that question involves a political decision that is beyond the scope of this report.« less

  16. Early Care and Education Issues Rising to the Top.

    ERIC Educational Resources Information Center

    Walker, Sherry Freeland, Ed.

    2001-01-01

    Noting that growing consensus about the importance of the first 5 years of life has prompted in-depth considerations about the systemic quality of early care and education in the United States, this issue of "State Education Leader" examines various aspects of early learning. Topics considered in this issue are: (1) key issues in financing early…

  17. A Citizen's Guide to U.S. Foreign Policy: Election '88. Nonpartisan Briefs on 18 Key Issues.

    ERIC Educational Resources Information Center

    Hoepli, Nancy, Ed.; And Others

    In order to make informed voting decisions citizens need background information on complex foreign policy issues facing the United States. This guide presents current issues and provides information to help citizens cast a thoughtful vote. The guide is divided into six main headings: Leadership; Security; Economic and Social Issues; Critical…

  18. Supply Issues for Science Academics in Australia: Now and in the Future

    ERIC Educational Resources Information Center

    Edwards, Daniel; Smith, T. Fred

    2010-01-01

    Australia, like the rest of the developed world, is in the midst of dealing with notable issues related to the age structure of its academic workforce. These issues are widespread and have been articulated in the Australian context most comprehensively by Hugo (2008). This paper investigates issues with demographic change and other key factors…

  19. The Text's the Thing: Using (Neglected) Issues of Textual Scholarship to Help Students Reimagine Shakespeare

    ERIC Educational Resources Information Center

    Parsons, Scott

    2009-01-01

    Do individuals know what words Shakespeare actually wrote? Exploring these issues can yield dramatic interest. With references to Shakespeare's Quartos and Folios, the author examines key textual issues and discrepancies in classroom studies of "Hamlet." (Contains 8 notes.)

  20. Satellite observation analysis of aerosols loading effect over Monrovia-Liberia

    NASA Astrophysics Data System (ADS)

    Emetere, M. E.; Esisio, F.; Oladapo, F.

    2017-05-01

    The effect of aerosols loading most often results in aerosols retention in the atmosphere. Aside the health hazards of aerosol retention, its effect on climate change are visible. In this research, it was proposed that the effect of aerosol retention also affects rain pattern. The Tropical Rainfall Measuring Mission (TRMM) layer 3 observations and the multi-imaging spectro-reflectometer (MISR) was used for the study. The aerosols loading over were investigated using sixteen years satellite observation in Monrovia-Liberia. Its effect on the rain rate over the region was documented. The results show that aerosol loading over the region is high and may have effect on farming in the nearest future. It was affirmed that the scanty AOD data was as a result of the rain rate that is higher within May and October.

  1. AmeriFlux Measurement Component (AMC) Instrument Handbook

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Reichl, Ken; Biraud, Sebastien C.

    2016-04-01

    An AMC system was installed at the U.S. Department of Energy (DOE)’s Atmospheric Radiation Measurement (ARM) Climate Research Facility North Slope of Alaska (NSA) Barrow site, also known as NSA C1 at the ARM Data Archive, in August 2012. A second AMC system was installed at the third ARM Mobile Facility deployment at Oliktok Point, also known as NSA M1. This in situ system consists of 12 combination soil temperature and volumetric water content (VWC) reflectometers and one set of upwelling and downwelling photosynthetically active radiation (PAR) sensors, all deployed within the fetch of the Eddy Correlation Flux Measurement System.more » Soil temperature and VWC sensors placed at two depths (10 and 30 cm below the vegetation layer) at six locations (or microsites) allow soil property inhomogeneity to be monitored across a landscape.« less

  2. [Blood-sugar self control. A means for the diabetic of controlling his metabolic management. Quality control of a battery-run pocket size reflectometer (glucose-meter)].

    PubMed

    Leidinger, F; Jörgens, V; Chantelau, E; Berchtold, P; Berger, M

    1980-07-26

    Home blood glucose monitoring by diabetic patients has recently been advocated as an effective means to improve metabolic control. The Glucocheck apparatus, a pocket-size battery-driven reflectance-meter (in Germany commercially available under the name Glucose-meter), has been evaluated for accuracy and practicability. In 450 blood glucose measurements, the variance between the values obtained using the Glucocheck apparatus and routine clinical laboratory procedures was +/- 11.7%. Especially in the low range of blood glucose concentrations, the Glucocheck method was very reliable. The quantitative precision of the Glucocheck method depends, however, quite considerably on the ability of the patient to use the apparatus correctly. In order to profit from Glucocheck in clinical practice, particular efforts to educate the patients in its use are necessary.

  3. Wafer characteristics via reflectometry

    DOEpatents

    Sopori, Bhushan L.

    2010-10-19

    Various exemplary methods (800, 900, 1000, 1100) are directed to determining wafer thickness and/or wafer surface characteristics. An exemplary method (900) includes measuring reflectance of a wafer and comparing the measured reflectance to a calculated reflectance or a reflectance stored in a database. Another exemplary method (800) includes positioning a wafer on a reflecting support to extend a reflectance range. An exemplary device (200) has an input (210), analysis modules (222-228) and optionally a database (230). Various exemplary reflectometer chambers (1300, 1400) include radiation sources positioned at a first altitudinal angle (1308, 1408) and at a second altitudinal angle (1312, 1412). An exemplary method includes selecting radiation sources positioned at various altitudinal angles. An exemplary element (1650, 1850) includes a first aperture (1654, 1854) and a second aperture (1658, 1858) that can transmit reflected radiation to a fiber and an imager, respectfully.

  4. System and method for determining coolant level and flow velocity in a nuclear reactor

    DOEpatents

    Brisson, Bruce William; Morris, William Guy; Zheng, Danian; Monk, David James; Fang, Biao; Surman, Cheryl Margaret; Anderson, David Deloyd

    2013-09-10

    A boiling water reactor includes a reactor pressure vessel having a feedwater inlet for the introduction of recycled steam condensate and/or makeup coolant into the vessel, and a steam outlet for the discharge of produced steam for appropriate work. A fuel core is located within a lower area of the pressure vessel. The fuel core is surrounded by a core shroud spaced inward from the wall of the pressure vessel to provide an annular downcomer forming a coolant flow path between the vessel wall and the core shroud. A probe system that includes a combination of conductivity/resistivity probes and/or one or more time-domain reflectometer (TDR) probes is at least partially located within the downcomer. The probe system measures the coolant level and flow velocity within the downcomer.

  5. Space Science Payloads Optical Properties Monitor (OPM) Mission Flight Anomalies Thermal Analyses

    NASA Technical Reports Server (NTRS)

    Schmitz, Craig P.

    2001-01-01

    The OPM was the first space payload that measured in-situ the optical properties of materials and had data telemetered to ground. The OPM was EVA mounted to the Mir Docking Module for an eight-month stay where flight samples were exposed to the Mir induced and natural environments. The OPM was comprised of three optical instruments; a total hemispherical spectral reflectometer, a vacuum ultraviolet spectrometer, and a total integrated scatterometer. There were also three environmental monitors; an atomic oxygen monitor, solar and infrared radiometers, and two temperature-controlled quartz crystal microbalances (to monitor contamination). Measurements were performed weekly and data telemetered to ground through the Mir data system. This paper will describe the OPM thermal control design and how the thermal math models were used to analyze anomalies which occurred during the space flight mission.

  6. Magnetic compound refractive lens for focusing and polarizing cold neutron beams.

    PubMed

    Littrell, K C; te Velthuis, S G E; Felcher, G P; Park, S; Kirby, B J; Fitzsimmons, M R

    2007-03-01

    Biconcave cylindrical lenses are used to focus beams of x rays or neutrons using the refractive properties of matter. In the case of neutrons, the refractive properties of magnetic induction can similarly focus and simultaneously polarize the neutron beam without the concomitant attenuation of matter. This concept of a magnetic refractive lens was tested using a compound lens consisting of 99 pairs of cylindrical permanent magnets. The assembly successfully focused the intensity of a white beam of cold neutrons of one spin state at the detector, while defocusing the other. This experiment confirmed that a lens of this nature may boost the intensity locally by almost an order of magnitude and create a polarized beam. An estimate of the performance of a more practically dimensioned device suitable for incorporation in reflectometers and slit-geometry small angle scattering instruments is given.

  7. Active cleaning technique for removing contamination from optical surfaces in space

    NASA Technical Reports Server (NTRS)

    Shannon, R. L.; Gillette, R. B.; Cruz, G. A.

    1973-01-01

    An active cleaning technique for removing contaminants from optical surfaces in space was investigated with emphasis on the feasibility of using plasma exposure as a means of in-situ cleaning. The major work accomplished includes: (1) development of an in-situ reflectometer for use in conjunction with the contaminant film deposition/cleaning facility; (2) completion of Apollo Telescope Mount (ATM) filter treatment experiments to assess the effects of plasma exposure on the UV transmittance; (3) attempts to correlate the atomic oxygen flux with cleaning rate; (4) completion of in-situ butadien contamination/plasma cleaning/UV reflectance measurement experiments; (5) carbon cleaning experiments using various gases; (6) completion of silicone contamination/cleaning experiments; and (7) experiments conducted at low chamber pressures to determine cleaning rate distribution and contamination of surfaces adjacent to those being cleaned.

  8. Measurement of large strains in ropes using plastic optical fibers

    DOEpatents

    Williams, Jerry Gene; Smith, David Barton; Muhs, Jeffrey David

    2006-02-14

    A method for the direct measurement of large strains in ropes in situ using a plastic optical fiber, for example, perfluorocarbon or polymethyl methacrylate and Optical Time-Domain Reflectometer or other light time-of-flight measurement instrumentation. Protective sheaths and guides are incorporated to protect the plastic optical fiber. In one embodiment, a small rope is braided around the plastic optical fiber to impose lateral compressive forces to restrain the plastic optical fiber from slipping and thus experience the same strain as the rope. Methods are described for making reflective interfaces along the length of the plastic optical fiber and to provide the capability to measure strain within discrete segments of the rope. Interpretation of the data allows one to calculate the accumulated strain at any point in time and to determine if the rope has experienced local damage.

  9. Social Work Practice with Latinos: Key Issues for Social Workers

    PubMed Central

    Furman, Rich; Negi, Nalini Junko; Iwamoto, Derek Kenji; Rowan, Diana; Shukraft, Allison; Gragg, Jennifer

    2010-01-01

    The Latino population is the fastest growing group in the United States; thus, it is imperative that social workers and other mental health practitioners be knowledgeable about the current literature on how to effectively serve this population. This article elucidates key issues and knowledge, such as immigration and migration concerns; discusses how to assess for levels of acculturation; examines cultural values; and highlights salient work issues and health disparities that Latinos experience. Recommendations on how agencies and universities can recruit and promote bilingual practitioners are introduced. Finally, culturally responsive strategies for professional use of self and fostering the therapeutic alliance are discussed. PMID:19366165

  10. Final report for the Integrated and Robust Security Infrastructure (IRSI) laboratory directed research and development project

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hutchinson, R.L.; Hamilton, V.A.; Istrail, G.G.

    1997-11-01

    This report describes the results of a Sandia-funded laboratory-directed research and development project titled {open_quotes}Integrated and Robust Security Infrastructure{close_quotes} (IRSI). IRSI was to provide a broad range of commercial-grade security services to any software application. IRSI has two primary goals: application transparency and manageable public key infrastructure. IRSI must provide its security services to any application without the need to modify the application to invoke the security services. Public key mechanisms are well suited for a network with many end users and systems. There are many issues that make it difficult to deploy and manage a public key infrastructure. IRSImore » addressed some of these issues to create a more manageable public key infrastructure.« less

  11. Overview of Variable Renewable Energy Regulatory Issues: A Clean Energy Regulators Initiative Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Miller, M.; Cox, S.

    This CERI report aims to provide an introductory overview of key regulatory issues associated with the deployment of renewable energy -- particularly variable renewable energy (VRE) sources such wind and solar power. The report draws upon the research and experiences from various international contexts, and identifies key ideas that have emerged from the growing body of VRE deployment experience and regulatory knowledge. The report assumes basic familiarity with regulatory concepts, and although it is not written for a technical audience, directs the reader to further reading when available. VRE deployment generates various regulatory issues: substantive, procedural, and public interest issues,more » and the report aims to provide an empirical and technical grounding for all three types of questions as appropriate.« less

  12. Security analysis and improvements to the PsychoPass method.

    PubMed

    Brumen, Bostjan; Heričko, Marjan; Rozman, Ivan; Hölbl, Marko

    2013-08-13

    In a recent paper, Pietro Cipresso et al proposed the PsychoPass method, a simple way to create strong passwords that are easy to remember. However, the method has some security issues that need to be addressed. To perform a security analysis on the PsychoPass method and outline the limitations of and possible improvements to the method. We used the brute force analysis and dictionary attack analysis of the PsychoPass method to outline its weaknesses. The first issue with the Psychopass method is that it requires the password reproduction on the same keyboard layout as was used to generate the password. The second issue is a security weakness: although the produced password is 24 characters long, the password is still weak. We elaborate on the weakness and propose a solution that produces strong passwords. The proposed version first requires the use of the SHIFT and ALT-GR keys in combination with other keys, and second, the keys need to be 1-2 distances apart. The proposed improved PsychoPass method yields passwords that can be broken only in hundreds of years based on current computing powers. The proposed PsychoPass method requires 10 keys, as opposed to 20 keys in the original method, for comparable password strength.

  13. Security Analysis and Improvements to the PsychoPass Method

    PubMed Central

    2013-01-01

    Background In a recent paper, Pietro Cipresso et al proposed the PsychoPass method, a simple way to create strong passwords that are easy to remember. However, the method has some security issues that need to be addressed. Objective To perform a security analysis on the PsychoPass method and outline the limitations of and possible improvements to the method. Methods We used the brute force analysis and dictionary attack analysis of the PsychoPass method to outline its weaknesses. Results The first issue with the Psychopass method is that it requires the password reproduction on the same keyboard layout as was used to generate the password. The second issue is a security weakness: although the produced password is 24 characters long, the password is still weak. We elaborate on the weakness and propose a solution that produces strong passwords. The proposed version first requires the use of the SHIFT and ALT-GR keys in combination with other keys, and second, the keys need to be 1-2 distances apart. Conclusions The proposed improved PsychoPass method yields passwords that can be broken only in hundreds of years based on current computing powers. The proposed PsychoPass method requires 10 keys, as opposed to 20 keys in the original method, for comparable password strength. PMID:23942458

  14. ERCMExpress. Volume 3, Issue 2

    ERIC Educational Resources Information Center

    Schonfeld, David J.

    2007-01-01

    The Emergency Response and Crisis Management (ERCM) Technical Assistance Center's newsletter, "ERCMExpress," provides comprehensive information on key issues in school emergency management. This issue of "ERCMExpress," titled "Coping with the Death of a Student or Staff Member," highlights the range of impact death can have on a school community;…

  15. Comprehensive Soldier Fitness (CSF) Experiment: Research Biases in the Development of the CSF

    DTIC Science & Technology

    2013-06-13

    issues that Soldiers were having, mostly during or returning from deployments. Issues such as PTSD, depression , and suicide . Seligman helped the...argues that the domains that are being measured do not necessarily link themselves to the key stressors that cause PTSD, depression , or suicide (Eidelson...or lessen any one of the key of stressors that cause PTSD, depression , and suicidality , which was supposed to be the results of the CSF (Eidelson

  16. Afterschool: A Key to Successful Parent Engagement. MetLife Foundation Afterschool Alert. Issue Brief No. 57

    ERIC Educational Resources Information Center

    Afterschool Alliance, 2012

    2012-01-01

    The Afterschool Alliance, in partnership with MetLife Foundation, is proud to present the third in its latest series of four issue briefs examining critical issues facing middle school youth and the vital role afterschool programs play in addressing these issues. This brief explores afterschool and parent engagement. There is little dispute…

  17. Implementation of the NCSS Guidelines for Teaching Science-Related Social Issues: Exemplar Lessons.

    ERIC Educational Resources Information Center

    Otto, Robert A., Ed.

    This document contains the Guidelines for Teaching Science-Related Social Issues adopted in 1982 by the National Council for the Social Studies and 10 examplar lessons each keyed to particular guidelines and drawing upon contemporary issues. The premise upon which the guidelines are based is that science is a social issue and that the examination…

  18. Data publication and dissemination of interactive keys under the open access model

    USDA-ARS?s Scientific Manuscript database

    The concepts of publication, citation and dissemination of interactive keys and other online keys are discussed and illustrated by a sample paper published in the present issue (doi: 10.3897/zookeys.21.271). The present model is based on previous experience with several existing examples of publishi...

  19. Issues for eHealth in Psychiatry: Results of an Expert Survey

    PubMed Central

    Huckvale, Kit; Larsen, Mark Erik; Basu, Ashna; Batterham, Philip J; Shaw, Frances; Sendi, Shahbaz

    2017-01-01

    Background Technology has changed the landscape in which psychiatry operates. Effective, evidence-based treatments for mental health care are now available at the fingertips of anyone with Internet access. However, technological solutions for mental health are not necessarily sought by consumers nor recommended by clinicians. Objective The objectives of this study are to identify and discuss the barriers to introducing eHealth technology-supported interventions within mental health. Methods An interactive polling tool was used to ask “In this brave new world, what are the key issues that need to be addressed to improve mental health (using technology)?” Respondents were the multidisciplinary attendees of the “Humans and Machines: A Quest for Better Mental Health” conference, held in Sydney, Australia, in 2016. Responses were categorized into 10 key issues using team-based qualitative analysis. Results A total of 155 responses to the question were received from 66 audience members. Responses were categorized into 10 issues and ordered by importance: access to care, integration and collaboration, education and awareness, mental health stigma, data privacy, trust, understanding and assessment of mental health, government and policy, optimal design, and engagement. In this paper, each of the 10 issues are outlined, and potential solutions are discussed. Many of the issues were interrelated, having implications for other key areas identified. Conclusions As many of the issues identified directly related to barriers to care, priority should be given to addressing these issues that are common across mental health delivery. Despite new challenges raised by technology, technology-supported mental health interventions represent a tremendous opportunity to address in a timely way these major concerns and improve the receipt of effective, evidence-based therapy by those in need. PMID:28246068

  20. Learning, Motivation, and Transfer: Successful Teacher Professional Development

    ERIC Educational Resources Information Center

    McDonald, Lex

    2012-01-01

    In this article, I am concerned with three key issues of teacher professional development--teacher learning, motivation, and transfer of learning. Each issue has received minimal attention in teacher professional development literature. The three issues are discussed, and a model of an integrative professional development approach is outlined,…

  1. Mathematical Problem Solving. Issues in Research.

    ERIC Educational Resources Information Center

    Lester, Frank K., Jr., Ed.; Garofalo, Joe, Ed.

    This set of papers was originally developed for a conference on Issues and Directions in Mathematics Problem Solving Research held at Indiana University in May 1981. The purpose is to contribute to the clear formulation of the key issues in mathematical problem-solving research by presenting the ideas of actively involved researchers. An…

  2. Current Issues Survey Report, 2007

    ERIC Educational Resources Information Center

    Camp, John S.; DeBlois, Peter B.

    2007-01-01

    The Eighth Annual EDUCAUSE Current Issues Survey asked campus information technology leaders to rate the most critical IT challenges facing them, their campuses, and/or their systems. Four findings associated with all respondents to this year's survey merit special mention. First, for the 2007 survey, the CIC decided to split a key issue choice…

  3. 77 FR 42085 - Federal Perkins Loan Program, Federal Family Education Loan Program, and William D. Ford Federal...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-07-17

    ... cohorts. Chart 1--Summary of the Proposed Regulations Issue and key features Benefits Cost/transfers... focus on issues related to streamlining institutional reporting requirements and proposed regulations... committee (the ``Loans Committee'') would address Federal student loan issues. The regulations considered by...

  4. Simple group password-based authenticated key agreements for the integrated EPR information system.

    PubMed

    Lee, Tian-Fu; Chang, I-Pin; Wang, Ching-Cheng

    2013-04-01

    The security and privacy are important issues for electronic patient records (EPRs). The goal of EPRs is sharing the patients' medical histories such as the diagnosis records, reports and diagnosis image files among hospitals by the Internet. So the security issue for the integrated EPR information system is essential. That is, to ensure the information during transmission through by the Internet is secure and private. The group password-based authenticated key agreement (GPAKE) allows a group of users like doctors, nurses and patients to establish a common session key by using password authentication. Then the group of users can securely communicate by using this session key. Many approaches about GAPKE employ the public key infrastructure (PKI) in order to have higher security. However, it not only increases users' overheads and requires keeping an extra equipment for storing long-term secret keys, but also requires maintaining the public key system. This investigation presents a simple group password-based authenticated key agreement (SGPAKE) protocol for the integrated EPR information system. The proposed SGPAKE protocol does not require using the server or users' public keys. Each user only remembers his weak password shared with a trusted server, and then can obtain a common session key. Then all users can securely communicate by using this session key. The proposed SGPAKE protocol not only provides users with convince, but also has higher security.

  5. Optical asymmetric watermarking using modified wavelet fusion and diffractive imaging

    NASA Astrophysics Data System (ADS)

    Mehra, Isha; Nishchal, Naveen K.

    2015-05-01

    In most of the existing image encryption algorithms the generated keys are in the form of a noise like distribution with a uniform distributed histogram. However, the noise like distribution is an apparent sign indicating the presence of the keys. If the keys are to be transferred through some communication channels, then this may lead to a security problem. This is because; the noise like features may easily catch people's attention and bring more attacks. To address this problem it is required to transfer the keys to some other meaningful images to disguise the attackers. The watermarking schemes are complementary to image encryption schemes. In most of the iterative encryption schemes, support constraints play an important role of the keys in order to decrypt the meaningful data. In this article, we have transferred the support constraints which are generated by axial translation of CCD camera using amplitude-, and phase- truncation approach, into different meaningful images. This has been done by developing modified fusion technique in wavelet transform domain. The second issue is, in case, the meaningful images are caught by the attacker then how to solve the copyright protection. To resolve this issue, watermark detection plays a crucial role. For this purpose, it is necessary to recover the original image using the retrieved watermarks/support constraints. To address this issue, four asymmetric keys have been generated corresponding to each watermarked image to retrieve the watermarks. For decryption, an iterative phase retrieval algorithm is applied to extract the plain-texts from corresponding retrieved watermarks.

  6. Technical Solutions to Common Indoor Air Quality Issues in Schools

    EPA Pesticide Factsheets

    Indoor Air Quality (IAQ) Design Tools for Schools provides voluntary guidance for school personnel, architects, engineers, builders and contractors, parents, and the community on key school construction and renovation issues.

  7. Catalyzing Gender Equality-Focused Clean Energy Development in West Africa

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    The Economic Community of West African States (ECOWAS) Regional Center for Renewable Energy and Energy Efficiency (ECREEE) partnered with the Clean Energy Solutions Center (Solutions Center), the African Development Bank and other institutions to develop a Situation Analysis of Energy and Gender Issues in ECOWAS Member States. Through a systematic approach to assess interlinked gender and energy issues in the region, the report puts forth a number of key findings. This brochure highlights ECREEE's partnership with the Solutions Center and key findings from the report.

  8. System design of the Pioneer Venus spacecraft. Volume 5: Probe vehicle studies

    NASA Technical Reports Server (NTRS)

    Nolte, L. J.; Stephenson, D. S.

    1973-01-01

    A summary of the key issues and studies conducted for the Pioneer Venus spacecraft and the resulting probe designs are presented. The key deceleration module issues are aerodynamic configuration and heat shield material selection. The design and development of the pressure vessel module are explained. Thermal control and science integration of the pressure vessel module are explained. The deceleration module heat shield, parachute and separation/despin are reported. The Thor/Delta and Atlas/Centaur baseline descriptions are provided.

  9. Earth Observatory Satellite system definition study. Report no. 3: Design/cost tradeoff studies

    NASA Technical Reports Server (NTRS)

    1974-01-01

    The key issues in the Earth Observatory Satellite (EOS) program which are subject to configuration study and tradeoff are identified. The issue of a combined operational and research and development program is considered. It is stated that cost and spacecraft weight are the key design variables and design options are proposed in terms of these parameters. A cost analysis of the EOS program is provided. Diagrams of the satellite configuration and subsystem components are included.

  10. Key Health Information Technologies and Related Issues for Iran: A Qualitative Study

    PubMed Central

    Hemmat, Morteza; Ayatollahi, Haleh; Maleki, Mohammadreza; Saghafi, Fatemeh

    2018-01-01

    Background and Objective: Planning for the future of Health Information Technology (HIT) requires applying a systematic approach when conducting foresight studies. The aim of this study was to identify key health information technologies and related issues for Iran until 2025. Methods: This was a qualitative study and the participants included experts and policy makers in the field of health information technology. In-depth semi-structured interviews were conducted and data were analyzed by using framework analysis and MAXQDA software. Results: The findings revealed that the development of national health information network, electronic health records, patient health records, a cloud-based service center, interoperability standards, patient monitoring technologies, telehealth, mhealth, clinical decision support systems, health information technology and mhealth infrastructure were found to be the key technologies for the future. These technologies could influence the economic, organizational and individual levels. To achieve them, the economic and organizational obstacles need to be overcome. Conclusion: In this study, a number of key technologies and related issues were identified. This approach can help to focus on the most important technologies in the future and to priorities these technologies for better resource allocation and policy making. PMID:29854016

  11. 12 CFR 7.5005 - National bank acting as digital certification authority.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... persons associated with a particular public/private key pair. As part of this service, the bank may also maintain a listing or repository of public keys. (b) A national bank may issue digital certificates verifying attributes in addition to identity of persons associated with a particular public/private key pair...

  12. 12 CFR 7.5005 - National bank acting as digital certification authority.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... persons associated with a particular public/private key pair. As part of this service, the bank may also maintain a listing or repository of public keys. (b) A national bank may issue digital certificates verifying attributes in addition to identity of persons associated with a particular public/private key pair...

  13. 12 CFR 7.5005 - National bank acting as digital certification authority.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... persons associated with a particular public/private key pair. As part of this service, the bank may also maintain a listing or repository of public keys. (b) A national bank may issue digital certificates verifying attributes in addition to identity of persons associated with a particular public/private key pair...

  14. 12 CFR 7.5005 - National bank acting as digital certification authority.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... persons associated with a particular public/private key pair. As part of this service, the bank may also maintain a listing or repository of public keys. (b) A national bank may issue digital certificates verifying attributes in addition to identity of persons associated with a particular public/private key pair...

  15. Safe, Healthy and Ready to Succeed: Arizona School Readiness Key Performance Indicators

    ERIC Educational Resources Information Center

    Migliore, Donna E.

    2006-01-01

    "Safe, Healthy and Ready to Succeed: Arizona School Readiness Key Performance Indicators" presents a set of baseline measurements that gauge how well a statewide system of school readiness supports is addressing issues that affect Arizona children's readiness for school. The Key Performance Indicators (KPIs) measure the system, rather…

  16. Effective user management with high strength crypto -key in dynamic group environment in cloud

    NASA Astrophysics Data System (ADS)

    Kumar, P. J.; Suganya, P.; Karthik, G.

    2017-11-01

    Cloud Clusters consists of various collections of files which are being accessed by multiple users of Cloud. The users are managed as a group and the association of the user to a particular group is dynamic in nature. Every group has a manager who handles the membership of a user to a particular group by issuing keys for encryption and decryption. Due to the dynamic nature of a user he/she may leave the group very frequently. But an attempt can be made by the user who has recently left the group to access a file maintained by that group. Key distribution becomes a critical issue while the behavior of the user is dynamic. Existing techniques to manage the users of group in terms of security and key distribution has been investigated so that to arrive at an objective to identify the scopes to increase security and key management scheme in cloud. The usage of various key combinations to measure the strength of security and efficiency of user management in dynamic cloud environment has been investigated.

  17. Exploring Ethical Issues Associated with Using Online Surveys in Educational Research

    ERIC Educational Resources Information Center

    Roberts, Lynne D.; Allen, Peter J.

    2015-01-01

    Online surveys are increasingly used in educational research, yet little attention has focused on ethical issues associated with their use in educational settings. Here, we draw on the broader literature to discuss 5 key ethical issues in the context of educational survey research: dual teacher/researcher roles; informed consent; use of…

  18. Defining and Measuring Engagement and Learning in Science: Conceptual, Theoretical, Methodological, and Analytical Issues

    ERIC Educational Resources Information Center

    Azevedo, Roger

    2015-01-01

    Engagement is one of the most widely misused and overgeneralized constructs found in the educational, learning, instructional, and psychological sciences. The articles in this special issue represent a wide range of traditions and highlight several key conceptual, theoretical, methodological, and analytical issues related to defining and measuring…

  19. Exploring E-Learning. IES Report 376.

    ERIC Educational Resources Information Center

    Pollard, E.; Hillage, J.

    This guide summarizes current research and commentary on e-learning, examining the key issues facing organizations exploring e-learning for employee development. The guide contains six sections. The first section provides an introduction to the issue of e-learning and a summary of the issues discussed in the remainder of the guide. Section 2…

  20. Screen Design for Children's Reading: Some Key Issues.

    ERIC Educational Resources Information Center

    Walker, Sue; Reynolds, Linda

    2000-01-01

    Draws attention to design issues that are likely to affect the way that children interact with screen-based information texts. Presents information based on the findings of the Interactive Multimedia in Primary Schools (IMPS) project funded by the British Library. Summarizes the design-related aspects of the project, highlighting those issues that…

  1. Issues and solutions: opportunities for European LED manufacturers

    NASA Astrophysics Data System (ADS)

    Pearsall, T. P.

    2007-09-01

    Marketing studies by EPIC show significant revenue opportunities by 2012 for UHB-LEDs in the automotive, LCD backlighting, and architectural lighting sectors. The goal of this workshop on manufacturing issues is to consider five key issues for UHB-LED manufacturing and to propose solutions that will pave the way to full exploitation of the opportunities.

  2. The Professional's Last Will and Testament.

    ERIC Educational Resources Information Center

    Lancaster, James M.

    2003-01-01

    In this article a case study illustrates the initial issues arising from the sudden death of key personnel, and then offers an outline for the Professional's Last Will and Testament. This document includes attention to logistical issues and planning for organizational change. It begins with short-term transition issues and continues through other,…

  3. The National Issues Forum: Bridging the Human Gap through Innovative Learning.

    ERIC Educational Resources Information Center

    McMahan, Eva M.

    The National Issues Forum model, a series of community based public discussions on key domestic issues, may be a partial solution to the "human gap" between growing complexity and a capacity to deal with it, by exemplifying "innovative learning." To engage in innovative learning, characterized by anticipation and participation,…

  4. USSR Space Life Sciences Digest. Index to issues 10-14

    NASA Technical Reports Server (NTRS)

    Hooke, Lydia Razran

    1988-01-01

    An index is provided for issues 10 through 14 of the USSR Space Life Sciences Digest. There are two sections. The first section lists bibliographic citations of abstracts contained in the Digest issues covered grouped by topic area categories. The second section provides a key word index for the same set of abstracts.

  5. Kohlberg and Gilligan: Duet or Duel?

    ERIC Educational Resources Information Center

    Jorgensen, Gunnar

    2006-01-01

    Most moral psychologists have come to accept two types of moral reasoning: Kohlberg's "justice" and Gilligan's "care", but there still seem to be some unresolved issues. By analysing and comparing Kohlberg's statement on some theoretical issues with some of Gilligan's statements in an interview in April 2003, I will look at some key issues in the…

  6. The 1986 NASP Survey: Comparison of Practitioners, NASP Leadership, and University Faculty on Key Issues.

    ERIC Educational Resources Information Center

    Reschly, Daniel J.; And Others

    National Association of School Psychologists (NASP) practitioner members (N=600), all recent members of the NASP leadership (N=139), and college faculty (N=166) responded to surveys on a variety of topics and issues including current demographic information, NASP priorities, credentialing, job satisfaction, issues related to learning disabilities…

  7. Emerging Issues in School, Family, & Community Connections. Annual Synthesis 2001

    ERIC Educational Resources Information Center

    Jordan, Catherine; Orozco, Evangelina; Averett, Amy

    2002-01-01

    This research synthesis is the first in a series that will examine key issues in the field of family and community connections with schools. The issues highlighted in this synthesis represent critical areas of work in family and community connections with schools where clarification, agreement, and further development are needed, as well as…

  8. Communicative Language Testing: Current Issues and Future Research

    ERIC Educational Resources Information Center

    Harding, Luke

    2014-01-01

    This article discusses a range of current issues and future research possibilities in Communicative Language Testing (CLT) using, as its departure point, the key questions which emerged during the CLT symposium at the 2010 Language Testing Forum. The article begins with a summary of the 2010 symposium discussion in which three main issues related…

  9. 75 FR 22783 - FIFRA Scientific Advisory Panel; Notice of Public Meeting

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-04-30

    ... Panel (FIFRA SAP) to consider and review a set of scientific issues related to the Comparative Adult and... some key scientific issues which are important in considering comparative age sensitivity for this...

  10. Special issue : safety advancements

    DOT National Transportation Integrated Search

    1999-04-24

    This issue of 'Status Report' focuses on some of the most recent key safety technology improvements. The crash protection in passenger vehicles is improving substantially; advanced frontal airbags will soon be available in a number of models and side...

  11. "Let Me Keep My Dead Husband's Sperm": Ethical Issues in Posthumous Reproduction.

    PubMed

    Panagiotopoulou, Nikoletta; Karavolos, Stamatios

    2015-01-01

    The feasibility of posthumous reproduction when the surviving partner is female has brought to light many ethical, moral, social, and legal issues. This review aims to summarize these issues and to assist clinicians who may be faced with such requests. A question list, used for health technologies assessment, was utilized in a question-answer approach as the review methodology. Of the 1,208 publications identified through a comprehensive literature search in biomedical, psychological, and ethical databases, 31 articles included arguments related to one or more questions from the predefined question set. Key stakeholders identified include the deceased, the requesting party, the resultant child, the physician, and society. Key ethical issues relevant to posthumous reproduction include the four traditional pillars of medical ethics--autonomy, beneficence, nonmaleficence, justice--as well as the stakeholders' rights and sociocultural attitudes. The ethical framework formulated by these issues has been incorporated in a clinical ethics decision-making tool that could prove useful to clinicians and decision makers. Copyright 2015 The Journal of Clinical Ethics. All rights reserved.

  12. Lightweight and scalable secure communication in VANET

    NASA Astrophysics Data System (ADS)

    Zhu, Xiaoling; Lu, Yang; Zhu, Xiaojuan; Qiu, Shuwei

    2015-05-01

    To avoid a message to be tempered and forged in vehicular ad hoc network (VANET), the digital signature method is adopted by IEEE1609.2. However, the costs of the method are excessively high for large-scale networks. The paper efficiently copes with the issue with a secure communication framework by introducing some lightweight cryptography primitives. In our framework, point-to-point and broadcast communications for vehicle-to-infrastructure (V2I) and vehicle-to-vehicle (V2V) are studied, mainly based on symmetric cryptography. A new issue incurred is symmetric key management. Thus, we develop key distribution and agreement protocols for two-party key and group key under different environments, whether a road side unit (RSU) is deployed or not. The analysis shows that our protocols provide confidentiality, authentication, perfect forward secrecy, forward secrecy and backward secrecy. The proposed group key agreement protocol especially solves the key leak problem caused by members joining or leaving in existing key agreement protocols. Due to aggregated signature and substitution of XOR for point addition, the average computation and communication costs do not significantly increase with the increase in the number of vehicles; hence, our framework provides good scalability.

  13. Exploring experiences of Personal Support Worker education in Ontario, Canada.

    PubMed

    Kelly, Christine

    2017-07-01

    There is growing attention to the training and education of Personal Support Workers, or PSWs, who work in community, home and long-term care settings supporting older people and people with disabilities. In Ontario, Canada, amid a volatile policy landscape, the provincial government launched an effort to standardise PSW education. Using qualitative methods, this study considered the question: What are the central educational issues reflected by students, working PSWs and key informants, and are they addressed by the PSW programme and training standards? Phase one was a public domain analysis completed between January and March 2014 and updated for major developments after that period. Phase two, completed between August 2014 and March 2015, included 15 key informant interviews and focus group discussions and mini-phone interviews with 35 working PSWs and current PSW students. According to the participants, the central educational issues are: casualisation of labour that is not conveyed in educational recruitment efforts, disconnect between theory and working conditions, overemphasis on long-term care as a career path, and variability of PSW education options. While the standards should help to address the final issue, they do not address the other key issues raised, which have to do with the structural organisation of work. There is thus a disconnect between the experiences of students, PSWs and key informants and the policy decisions surrounding this sector. This is particularly significant as education is often touted as a panacea for issues in long-term and community care. In fact, the curriculum of some of the PSW programmes, especially those in public college settings, is robust. Yet, the underlying issues will remain barring a structural overhaul of the organisation of long-term and community care sectors founded on a social revaluing of older people and the gendered work of care. © 2017 John Wiley & Sons Ltd.

  14. Lunar surface magnetic fields and their interaction with the solar wind: results from lunar prospector

    PubMed

    Lin; Mitchell; Curtis; Anderson; Carlson; McFadden; Acuna; Hood; Binder

    1998-09-04

    The magnetometer and electron reflectometer experiment on the Lunar Prospector spacecraft has obtained maps of lunar crustal magnetic fields and observed the interaction between the solar wind and regions of strong crustal magnetic fields at high selenographic latitude (30 degreesS to 80 degreesS) and low ( approximately 100 kilometers) altitude. Electron reflection maps of the regions antipodal to the Imbrium and Serenitatis impact basins, extending to 80 degreesS latitude, show that crustal magnetic fields fill most of the antipodal zones of those basins. This finding provides further evidence for the hypothesis that basin-forming impacts result in magnetization of the lunar crust at their antipodes. The crustal magnetic fields of the Imbrium antipode region are strong enough to deflect the solar wind and form a miniature (100 to several hundred kilometers across) magnetosphere, magnetosheath, and bow shock system.

  15. Fast coarse-fine locating method for φ-OTDR.

    PubMed

    Mei, Xuanwei; Pang, Fufei; Liu, Huanhuan; Yu, Guoqin; Shao, Yuying; Qian, Tianyu; Mou, Chengbo; Lv, Longbao; Wang, Tingyun

    2018-02-05

    We proposed and demonstrated a coarse-fine method to achieve fast locating of external vibration for the phase-sensitive optical time-domain reflectometer (φ-OTDR) sensing system. Firstly, the acquired backscattered traces from heterodyne coherent φ-OTDR systems are spatially divided into a few segments along a sensing fiber for coarse locating, and most of the acquired data can be excluded by comparing the phase difference between the endpoints in adjacent segments. Secondly, the amplitude-based locating is implemented within the target segments for fine locating. By using the proposed coarse-fine locating method, we have numerically and experimentally investigated a distributed vibration sensor based on the heterodyne coherent φ-OTDR system with a 50-km-long sensing fiber. We find that the computation cost of signal processing for locating is significantly reduced in the long-haul sensing fiber, showing a potential application in real-time locating of external vibration.

  16. Method and apparatus for probing relative volume fractions

    DOEpatents

    Jandrasits, Walter G.; Kikta, Thomas J.

    1998-01-01

    A relative volume fraction probe particularly for use in a multiphase fluid system includes two parallel conductive paths defining therebetween a sample zone within the system. A generating unit generates time varying electrical signals which are inserted into one of the two parallel conductive paths. A time domain reflectometer receives the time varying electrical signals returned by the second of the two parallel conductive paths and, responsive thereto, outputs a curve of impedance versus distance. An analysis unit then calculates the area under the curve, subtracts the calculated area from an area produced when the sample zone consists entirely of material of a first fluid phase, and divides this calculated difference by the difference between an area produced when the sample zone consists entirely of material of the first fluid phase and an area produced when the sample zone consists entirely of material of a second fluid phase. The result is the volume fraction.

  17. Anomalous X-Ray Reflectivity Characterization of Ion Distribution at Biomimetic Membranes

    NASA Astrophysics Data System (ADS)

    Vaknin, David; Krüger, Peter; Lösche, Mathias

    2003-05-01

    Anomalous x-ray reflectivity measurements provides detailed information on ion binding to biomembrane surfaces. Using a monochromatic beam tuned to various x-ray energies at the Argonne National Laboratory Advanced Photon Source and utilizing a newly commissioned x-ray liquid surfaces reflectometer, measurements at and away from ion absorption edges allow determination of the distribution of these ions as they accumulate near lipid membranes. As a model, the interaction of Ba2+ ions with DMPA- (1,2-dimyristoyl-sn-glycero-3-phosphatidic acid) monolayers at the aqueous surface is studied. We find an unexpectedly large concentration of barium at the interface, ≈1.5 per DMPA-, forming a Stern layer of bound ions and a cloud of less densely bound ions near the lipid headgroups. This result can be understood only if one assumes that bound cations are partially speciated, e.g., as BaOH+.

  18. Electrophysical properties of water and ice under isentropic compression to megabar pressures

    NASA Astrophysics Data System (ADS)

    Belov, S. I.; Boriskov, G. V.; Bykov, A. I.; Dolotenko, M. I.; Egorov, N. I.; Korshunov, A. S.; Kudasov, Yu. B.; Makarov, I. V.; Selemir, V. D.; Filippov, A. V.

    2017-02-01

    The relative permittivity and specific conductivity of water and ice are measured under isentropic compression to pressures above 300 GPa. Compression is initiated by a pulse of an ultrahigh magnetic field generated by an MK-1 magnetocumulative generator. The sample is placed in a coaxial compression chamber with an initial volume of about 40 cm3. The complex relative permittivity was measured by a fast-response reflectometer at a frequency of about 50 MHz. At the compression of water, its relative permittivity increases to ɛ = 350 at a pressure of 8 GPa, then drops sharply to ɛ = 140, and further decreases smoothly. It is shown that measurements of the relative permittivity under isentropic compression make it possible to determine interfaces between ordered and disordered phases of water and ice, as well as to reveal features associated with a change in the activation energy of defects.

  19. Method and apparatus for probing relative volume fractions

    DOEpatents

    Jandrasits, W.G.; Kikta, T.J.

    1998-03-17

    A relative volume fraction probe particularly for use in a multiphase fluid system includes two parallel conductive paths defining therebetween a sample zone within the system. A generating unit generates time varying electrical signals which are inserted into one of the two parallel conductive paths. A time domain reflectometer receives the time varying electrical signals returned by the second of the two parallel conductive paths and, responsive thereto, outputs a curve of impedance versus distance. An analysis unit then calculates the area under the curve, subtracts the calculated area from an area produced when the sample zone consists entirely of material of a first fluid phase, and divides this calculated difference by the difference between an area produced when the sample zone consists entirely of material of the first fluid phase and an area produced when the sample zone consists entirely of material of a second fluid phase. The result is the volume fraction. 9 figs.

  20. Distributed Humidity Sensing in PMMA Optical Fibers at 500 nm and 650 nm Wavelengths.

    PubMed

    Liehr, Sascha; Breithaupt, Mathias; Krebber, Katerina

    2017-03-31

    Distributed measurement of humidity is a sought-after capability for various fields of application, especially in the civil engineering and structural health monitoring sectors. This article presents a method for distributed humidity sensing along polymethyl methacrylate (PMMA) polymer optical fibers (POFs) by analyzing wavelength-dependent Rayleigh backscattering and attenuation characteristics at 500 nm and 650 nm wavelengths. Spatially resolved humidity sensing is obtained from backscatter traces of a dual-wavelength optical time domain reflectometer (OTDR). Backscatter dependence, attenuation dependence as well as the fiber length change are characterized as functions of relative humidity. Cross-sensitivity effects are discussed and quantified. The evaluation of the humidity-dependent backscatter effects at the two wavelength measurements allows for distributed and unambiguous measurement of relative humidity. The technique can be readily employed with low-cost standard polymer optical fibers and commercial OTDR devices.

  1. Towards neutron scattering experiments with sub-millisecond time resolution

    DOE PAGES

    Adlmann, F. A.; Gutfreund, Phillip; Ankner, John Francis; ...

    2015-02-01

    Neutron scattering techniques offer several unique opportunities in materials research. However, most neutron scattering experiments suffer from the limited flux available at current facilities. This limitation becomes even more severe if time-resolved or kinetic experiments are performed. A new method has been developed which overcomes these limitations when a reversible process is studied, without any compromise on resolution or beam intensity. We demonstrate that, by recording in absolute time the neutron detector events linked to an excitation, information can be resolved on sub-millisecond timescales. Specifically, the concept of the method is demonstrated by neutron reflectivity measurements in time-of-flight mode atmore » the Liquids Reflectometer located at the Spallation Neutron Source, Oak Ridge National Laboratory, Tennessee, USA, combined with in situ rheometry. Finally, the opportunities and limitations of this new technique are evaluated by investigations of a micellar polymer solution offering excellent scattering contrast combined with high sensitivity to shear.« less

  2. Experimental, water droplet impingement data on two-dimensional airfoils, axisymmetric inlet and Boeing 737-300 engine inlet

    NASA Technical Reports Server (NTRS)

    Papadakis, M.; Elangovan, E.; Freund, G. A., Jr.; Breer, M. D.

    1987-01-01

    An experimental method has been developed to determine the droplet impingement characteristics on two- and three-dimensional bodies. The experimental results provide the essential droplet impingement data required to validate particle trajectory codes, used in aircraft icing analyses and engine inlet particle separator analyses. A body whose water droplet impingement characteristics are required is covered at strategic locations by thin strips of moisture absorbing (blotter) paper, and then exposed to an air stream containing a dyed-water spray cloud. Water droplet impingement data are extracted from the dyed blotter strips, by measuring the optical reflectance of the dye deposit on the strips, using an automated reflectometer. Impingement efficiency data obtained for a NACA 65(2)015 airfoil section, a supercritical airfoil section, and Being 737-300 and axisymmetric inlet models are presented in this paper.

  3. Method and apparatus for active tamper indicating device using optical time-domain reflectometry

    DOEpatents

    Smith, D. Barton; Muhs, Jeffrey D.; Pickett, Chris A.; Earl, D. Duncan

    1999-01-01

    An optical time-domain reflectometer (OTDR) launches pulses of light into a link or a system of multiplexed links and records the waveform of pulses reflected by the seals in the link(s). If a seal is opened, the link of cables will become a discontinuous transmitter of the light pulses and the OTDR can immediately detect that a seal has been opened. By analyzing the waveform, the OTDR can also quickly determine which seal(s) were opened. In this way the invention functions as a system of active seals. The invention is intended for applications that require long-term surveillance of a large number of closures. It provides immediate tamper detection, allows for periodic access to secured closures, and can be configured for many different distributions of closures. It can monitor closures in indoor and outdoor locations and it can monitor containers or groups of containers located many kilometers apart.

  4. Simultaneous reflectometry and interferometry for measuring thin-film thickness and curvature

    NASA Astrophysics Data System (ADS)

    Arends, A. A.; Germain, T. M.; Owens, J. F.; Putnam, S. A.

    2018-05-01

    A coupled reflectometer-interferometer apparatus is described for thin-film thickness and curvature characterization in the three-phase contact line region of evaporating fluids. Validation reflectometry studies are provided for Au, Ge, and Si substrates and thin-film coatings of SiO2 and hydrogel/Ti/SiO2. For interferometry, liquid/air and solid/air interferences are studied, where the solid/air samples consisted of glass/air/glass wedges, cylindrical lenses, and molded polydimethylsiloxane lenses. The liquid/air studies are based on steady-state evaporation experiments of water and isooctane on Si and SiO2/Ti/SiO2 wafers. The liquid thin-films facilitate characterization of both (i) the nano-scale thickness of the absorbed fluid layer and (ii) the macro-scale liquid meniscus thickness, curvature, and curvature gradient profiles. For our validation studies with commercial lenses, the apparatus is shown to measure thickness profiles within 4.1%-10.8% error.

  5. Sensitivity of a fibre scattered-light interferometer to external phase perturbations in an optical fibre

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Alekseev, A E; Potapov, V T; Gorshkov, B G

    2015-10-31

    Sensitivity of a fibre scattered-light interferometer to external phase perturbations is studied for the first time. An expression is derived for an average power of a useful signal at the interferometer output under external harmonic perturbations in a signal fibre of the interferometer. It is shown that the maximum sensitivity of the scattered-light interferometer depends on the dispersion of the interferogram intensity. An average signal-to-noise ratio is determined theoretically and experimentally at the output of the interferometer at different amplitudes of external perturbations. Using the measured dependences of the signal-to-noise ratio, the threshold sensitivity of the fibre scattered-light interferometer tomore » external phase perturbations is found. The results obtained can be used to optimise characteristics of optical time-domain reflectometers and to design individual phase-sensitive fibre-optic sensors. (laser applications and other topics in quantum electronics)« less

  6. Optical properties of ion beam textured metals. [using copper, silicon, aluminum, titanium and stainless steels

    NASA Technical Reports Server (NTRS)

    Hudson, W. R.; Weigand, A. J.; Mirtich, M. J.

    1977-01-01

    Copper, silicon, aluminum, titanium and 316 stainless steel were textured by 1000 eV xenon ions from an 8 cm diameter electron bombardment ion source. Simultaneously sputter-deposited tantalum was used to facilitate the development of the surface microstructure. Scanning electron microscopy of the ion textured surfaces revealed two types of microstructure. Copper, silicon, and aluminum developed a cone structure with an average peak-to-peak distance ranging from 1 micron for silicon to 6 microns for aluminum. Titanium and 316 stainless steel developed a serpentine ridge structure. The average peak-to-peak distance for both of these materials was 0.5 micron. Spectral reflectance was measured using an integrating sphere and a holraum reflectometer. Total reflectance for air mass 0 and 2, solar absorptance and total emittance normalized for a 425 K black body were calculated from the reflectance measurements.

  7. Neural network evaluation of reflectometry density profiles for control purposes

    NASA Astrophysics Data System (ADS)

    Santos, J.; Nunes, F.; Manso, M.; Nunes, I.

    1999-01-01

    Broadband reflectometry is a diagnostic that is able to measure the density profile with high spatial and temporal resolutions, therefore it can be used to improve the performance of advanced tokamak operation modes and to supplement or correct the magnetics for plasma position control. To perform these tasks real-time processing is needed. Here we present a method that uses a neural network to make a fast evaluation of radial positions for selected density layers. Typical ASDEX Upgrade density profiles were used to generate the simulated network training and test sets. It is shown that the method has the potential to meet the tight timing requirements of control applications with the required accuracy. The network is also able to provide an accurate estimation of the position of density layers below the first density layer which is probed by an O-mode reflectometer, provided that it is trained with a realistic density profile model.

  8. Inversion of Gravity and Magnetic Field Data for Tyrrhena Patera

    NASA Technical Reports Server (NTRS)

    Milbury, C.; Schubert, G.; Raymond, C. A.; Smrekar, S. E.

    2011-01-01

    Tyrrhena Patera is located to the southeast/northeast of the Isidis/Hellas impact basin. It was geologically active into the Late Amazonian, although the main edifice was formed in the Noachian(approximately 3.7-4.0 Ga). Tyrrhena Patera and the surrounding area contain gravity and magnetic anomalies that appear to be correlated. The results presented here are for the anomalies 1a and 1b (closest to Tyrrhena Patera), however other anomalies in this region have been modeled and will be presented at the conference.The Mars Global Surveyor (MGS) free-air gravity signature of Tyrrhena Patera has been studied by Kiefer, who inferred the existence of an extinct magma chamber below it. The magnetic signature has been mapped by Lillis R. J. et al., who compared electron reflectometer data, analogous to the total magnetic field, for Syrtis Major and Tyrrhena Patera and argued for demagnetization of both volcanoes.

  9. Integrated optics reflectometer

    DOEpatents

    Couch, Philip R; Murphy, Kent A.; Gunther, Michael F; Gause, Charles B

    2017-01-31

    An apparatus includes a laser source configured to output laser light at a target frequency, and a measurement unit configured to measure a deviation between an actual frequency outputted by the laser source at a current period of time and the target frequency of the laser source. The apparatus includes a feedback control unit configured to, based on the measured deviation between the actual and target frequencies, control the laser source to maintain a constant frequency of laser output from the laser source so that the frequency of laser light transmitted from the laser source is adjusted to the target frequency. The feedback control unit can control the laser source to maintain a linear rate of change in the frequency of its laser light output, and compensate for characteristics of the measurement unit utilized for frequency measurement. A method is provided for performing the feedback control of the laser source.

  10. Human Health Effects of Biphenyl: Key Findings and Scientific Issues.

    PubMed

    Li, Zheng; Hogan, Karen A; Cai, Christine; Rieth, Susan

    2016-06-01

    In support of the Integrated Risk Information System (IRIS), the U.S. Environmental Protection Agency (EPA) has evaluated the human health hazards of biphenyl exposure. We review key findings and scientific issues regarding expected human health effects of biphenyl. Scientific literature from 1926 through September 2012 was critically evaluated to identify potential human health hazards associated with biphenyl exposure. Key issues related to the carcinogenicity and noncancer health hazards of biphenyl were examined based on evidence from experimental animal bioassays and mechanistic studies. Systematic consideration of experimental animal studies of oral biphenyl exposure took into account the variety of study designs (e.g., study sizes, exposure levels, and exposure durations) to reconcile differing reported results. The available mechanistic and toxicokinetic evidence supports the hypothesis that male rat urinary bladder tumors arise through urinary bladder calculi formation but is insufficient to hypothesize a mode of action for liver tumors in female mice. Biphenyl and its metabolites may induce genetic damage, but a role for genotoxicity in biphenyl-induced carcinogenicity has not been established. The available health effects data for biphenyl provides suggestive evidence for carcinogenicity in humans, based on increased incidences of male rat urinary bladder tumors at high exposure levels and on female mouse liver tumors. Kidney toxicity is also a potential human health hazard of biphenyl exposure. Li Z, Hogan KA, Cai C, Rieth S. 2016. Human health effects of biphenyl: key findings and scientific issues. Environ Health Perspect 124:703-712; http://dx.doi.org/10.1289/ehp.1509730.

  11. Clinical Trials: A Crucial Key to Human Health Research

    MedlinePlus

    ... Clinical Trials: A Crucial Key to Human Health Research Past Issues / Summer 2006 Table of Contents For ... Photo: PhotoDisc At the forefront of human health research today are clinical trials—studies that use human ...

  12. Bulimia: A Self-Psychological and Ego-Developmental View.

    ERIC Educational Resources Information Center

    Brenner-Liss, Deborah

    1986-01-01

    Discusses key clinical issues in the treatment of bulimia with clinical examples from a self-psychological and ego-developmental point of view. Identifies three developmental issues for bulimia: self-regulatory, differentiation, and self-esteem. (Author/ABB)

  13. Issues in the Management of Distance Education.

    ERIC Educational Resources Information Center

    Murgatroyd, Stephen; Woudstra, Andrew

    1989-01-01

    Examines key issues facing administrators at Athabasca University and discusses their implications for distance education organizations. Topics discussed include strategic planning; accountability and cost effectiveness; consortia and cooperation; instructional design; managing technological innovation; marketing; quality assurance; and…

  14. Keys to Recovery after Knee Replacement Surgery | NIH MedlinePlus the Magazine

    MedlinePlus

    Skip to main content NIH MedlinePlus the Magazine NIH MedlinePlus Salud Download the Current Issue PDF [1.5 mb] Trusted Health Information from the National Institutes of Health Home Current Issue ...

  15. Ethical Responsibility Key to Computer Security.

    ERIC Educational Resources Information Center

    Lynn, M. Stuart

    1989-01-01

    The pervasiveness of powerful computers and computer networks has raised the specter of new forms of abuse and of concomitant ethical issues. Blurred boundaries, hackers, the Computer Worm, ethical issues, and implications for academic institutions are discussed. (MLW)

  16. The nursing shortage: an update for occupational health nurses.

    PubMed

    Palmer, Carol

    2003-12-01

    Nursing is about to realize the worst shortage in history at the same time the first baby boomers are increasing the need for health care. A large component of the current and projected nursing shortage is the aging of the RN work force. Several factors contribute to the aging of the work force, including overall decline in nursing as a chosen profession, the increasing age of nursing graduates, and the aging of the existing RN work force. Job dissatisfaction has been a key issue contributing to the crisis related to recruitment and retention of nurses. Inadequate staffing, heavy workloads, flat salaries, and increased use of mandatory overtime are primary issues related to job dissatisfaction. Job dissatisfaction issues are key components of retention of nursing personnel. Occupational health nurses are experts in dealing with issues of ergonomic challenges, workplace violence, mandatory overtime, stress related injuries, and high stress associated with nursing.

  17. Emerging issues in biodiversity & conservation management: The need for a palaeoecological perspective

    NASA Astrophysics Data System (ADS)

    Froyd, C. A.; Willis, K. J.

    2008-09-01

    The study of Quaternary environmental change is directly applicable to on-going issues of global conservation. Palaeoecological research techniques provide the tools to address some of the key questions presently being asked by conservation ecologists and land management organizations. But is this type of analysis currently being utilized to its full potential? Are the results of palaeoenvironmental analyses routinely applied to practical issues of natural resource management, and if not what can be done to expand the application of this research within the conservation community? This paper reviews recent developments in the application of the analysis of late Quaternary environmental change to key environmental issues of biodiversity and conservation management and examines areas which could be strengthened in the future including: (i) determination of baselines and natural ecosystem variability; (ii) understanding ecological thresholds and resilience; (iii) climate change conservation strategies; (iv) biological invasions; and (v) conservation and culture.

  18. Managing the pursuit of health and wealth: the key challenges.

    PubMed

    Fidler, David P; Drager, Nick; Lee, Kelley

    2009-01-24

    This article forms part of a six-part Series on trade and health, and sets the stage for this Series by analysing key aspects of the relationship between trade and health. The Series takes stock of this relation and provides timely analysis of the key challenges facing efforts to achieve an appropriate balance between trade and health across a diverse range of issues. This introductory article reviews how trade and health have risen and expanded on global policy agendas in the past decade in unprecedented ways, describes how trade and health issues are respectively governed in international relations, examines the ongoing search for policy coherence between the two policy spheres, and highlights the topics of the remaining articles in the Series.

  19. Managing the pursuit of health and wealth: the key challenges

    PubMed Central

    Fidler, David P; Drager, Nick; Lee, Kelley

    2009-01-01

    This article forms part of a six-part Series on trade and health, and sets the stage for this Series by analysing key aspects of the relationship between trade and health. The Series takes stock of this relation and provides timely analysis of the key challenges facing efforts to achieve an appropriate balance between trade and health across a diverse range of issues. This introductory article reviews how trade and health have risen and expanded on global policy agendas in the past decade in unprecedented ways, describes how trade and health issues are respectively governed in international relations, examines the ongoing search for policy coherence between the two policy spheres, and highlights the topics of the remaining articles in the Series. PMID:19167061

  20. Understanding Price Elasticities to Inform Public Health Research and Intervention Studies: Key Issues

    PubMed Central

    Nghiem, Nhung; Genç, Murat; Blakely, Tony

    2013-01-01

    Pricing policies such as taxes and subsidies are important tools in preventing and controlling a range of threats to public health. This is particularly so in tobacco and alcohol control efforts and efforts to change dietary patterns and physical activity levels as a means of addressing increases in noncommunicable diseases. To understand the potential impact of pricing policies, it is critical to understand the nature of price elasticities for consumer products. For example, price elasticities are key parameters in models of any food tax or subsidy that aims to quantify health impacts and cost-effectiveness. We detail relevant terms and discuss key issues surrounding price elasticities to inform public health research and intervention studies. PMID:24028228

  1. Gender, Literacy and Women's Empowerment in India: Some Issues

    ERIC Educational Resources Information Center

    Ghose, Malini

    2007-01-01

    The note discusses some key issues pertaining to gender, literacy and women's empowerment in India. It uses disaggregated data to illustrate the persisting gender disparities with regard to literacy and points out that despite this there is a lack of real political will to address issues of adult literacy. It further draws on data from the…

  2. Making Hawai'i's Kids Count. Issue Paper Number 3.

    ERIC Educational Resources Information Center

    Hawaii Univ., Manoa. Center on the Family.

    This issue paper from Hawai'i Kids Count addresses the issue of teen pregnancy and birth rates. The paper notes that teen pregnancy and birth rates are declining both nationally and in Hawaii and describes key risk factors associated with having a baby before age 20: (1) early school failure; (2) early behavioral problems; (3) family dysfunction;…

  3. America's People: An Imperiled Resource. National Urban Policy Issues for a New Federal Administration.

    ERIC Educational Resources Information Center

    National Association of State Universities and Land Grant Colleges, Washington, DC.

    This report seeks to identify and make policy recommendations concerning major urban issues confronting the Bush Administration. The Division of Urban Affairs of the National Association of State Universities and Land-Grant Colleges (NASULGC) established working groups and commissioned papers on the following six key urban policy issues: (1)…

  4. Excellence at Work. Policy Option Papers for the National Governors' Association.

    ERIC Educational Resources Information Center

    Ganzglass, Evelyn, Ed.

    This volume contains an introduction and four policy option papers that explore key issues affecting the economy and state options to address the issues within the context of the U.S. workplace. "Introduction" (David Bedford, Evelyn Ganzglass) discusses the issues identified in the first phase of the governors' initiative on Excellence at Work and…

  5. Using Statistics to Explore Cross-Curricular and Social Issues Opportunities

    ERIC Educational Resources Information Center

    Day, Lorraine

    2013-01-01

    The area of statistics is one in which teachers may be encouraged to make important links to other curriculum areas and social issues. Statistical literacy is a key component of being numerate and living as an informed citizen. The teaching of statistics provides an opportunity to inform and educate students about social issues and moral…

  6. Connections 2015: Our History: Journeys in KF Research. Annual Newsletter

    ERIC Educational Resources Information Center

    Gilmore, Melinda, Ed.; Holwerk, David, Ed.

    2015-01-01

    Each issue of this annual newsletter focuses on a particular area of Kettering's research. The 2015 issue focuses on a yearlong review of Kettering's research over time. This issue contains the following articles that address this review: (1) How Kettering Discovered Democracy (David Mathews); (2) Key Events in KF History (Collette McDonough); (3)…

  7. The effect of touch-key size on the usability of In-Vehicle Information Systems and driving safety during simulated driving.

    PubMed

    Kim, Heejin; Kwon, Sunghyuk; Heo, Jiyoon; Lee, Hojin; Chung, Min K

    2014-05-01

    Investigating the effect of touch-key size on usability of In-Vehicle Information Systems (IVISs) is one of the most important research issues since it is closely related to safety issues besides its usability. This study investigated the effects of the touch-key size of IVISs with respect to safety issues (the standard deviation of lane position, the speed variation, the total glance time, the mean glance time, the mean time between glances, and the mean number of glances) and the usability of IVISs (the task completion time, error rate, subjective preference, and NASA-TLX) through a driving simulation. A total of 30 drivers participated in the task of entering 5-digit numbers with various touch-key sizes while performing simulated driving. The size of the touch-key was 7.5 mm, 12.5 mm, 17.5 mm, 22.5 mm and 27.5 mm, and the speed of driving was set to 0 km/h (stationary state), 50 km/h and 100 km/h. As a result, both the driving safety and the usability of the IVISs increased as the touch-key size increased up to a certain size (17.5 mm in this study), at which they reached asymptotes. We performed Fitts' law analysis of our data, and this revealed that the data from the dual task experiment did not follow Fitts' law. Copyright © 2013 Elsevier Ltd and The Ergonomics Society. All rights reserved.

  8. The Children's Inn at NIH Anniversary Key Messages | NIH MedlinePlus the Magazine

    MedlinePlus

    ... Past Issues / Summer 2014 Table of Contents Anniversary Key Messages Playground and Park at The Children's Inn ... and commitment, and the merging of public and private resources. Merck generously donated $3.7 million for ...

  9. Highway reservation system design and its application to freight transportation.

    DOT National Transportation Integrated Search

    2014-05-01

    Congestion and safety associated with freight trucks are key issues that arise in the context of highway : transportation, especially in the heavily-traveled commercial corridors. To address these issues, truck-only lanes for freight trucks have been...

  10. Three Reaction Papers.

    ERIC Educational Resources Information Center

    Dominic, Joseph F.; And Others

    1983-01-01

    With regard to the preceding articles in this issue, Joseph F. Dominic identifies key ideas of the research on writing, Susan Florio-Ruane points out similarities and differences among the articles, and Nancy L. Stein discusses methodological and conceptual issues in writing research. (RH)

  11. ERCMExpress. Volume 3, Issue 5

    ERIC Educational Resources Information Center

    Taylor, Matt

    2007-01-01

    The Emergency Response and Crisis Management (ECRM) Technical Assistance Center's newsletter "ERCMExpress" provides comprehensive information on key issues in school emergency management. Many nontraditional schools across the United States, such as storefront schools, rural schools, and alternative education facilities, face challenges…

  12. Classrooms.

    ERIC Educational Resources Information Center

    Butin, Dan

    This paper addresses classroom design trends and the key issues schools should consider for better classroom space flexibility and adaptability. Classroom space design issues when schools embrace technology are discussed, as are design considerations when rooms must accommodate different grade levels, the importance of lighting, furniture…

  13. Ten key issues in modern flow chemistry.

    PubMed

    Wegner, Jens; Ceylan, Sascha; Kirschning, Andreas

    2011-04-28

    Ten essentials of synthesis in the flow mode, a new enabling technology in organic chemistry, are highlighted as flashlighted providing an insight into current and future issues and developments in this field. © The Royal Society of Chemistry 2011

  14. A guide to Social Security money's worth issues.

    PubMed

    Leimer, D R

    1995-01-01

    This article discusses some of the major issues associated with the question of whether workers receive their money's worth from the Social Security program. An effort is made to keep the discussion as nontechnical as possible, with explanations provided for many of the technical terms and concepts found in the money's worth literature. Major assumptions, key analytical methods, and money's worth measures used in the literature are also discussed. Finally, the key findings of money's worth studies are summarized, with some cautions concerning the limitations and appropriate usage of money's worth analyses.

  15. EPA's Reanalysis of Key Issues Related to Dioxin Toxicity and ...

    EPA Pesticide Factsheets

    EPA is releasing the draft report, EPA's Reanalysis of Key Issues Related to Dioxin Toxicity and Response to NAS Comments (Volume 1), that was distributed to Federal agencies and White House Offices for comment during the Science Discussion step of the IRIS Assessment Development Process. Comments received from other Federal agencies and White House Offices are provided below with external peer review panel comments. The objective of this report is to respond to the NAS coments on dose-response modeling conducted in the EPA Reassessment of the health effects associated with dioxin exposure.

  16. Impact Assessment and Forecasts of Information and Telecommunications Technologies Applied to Education and Training. R&D in Information and Communication Based Learning Technology. Analysis of Key Issues for the Orientation of the Work of Sector Actors in the Framework of DELTA. Volume I--Executive Summary.

    ERIC Educational Resources Information Center

    Commission of the European Communities, Brussels (Belgium).

    This report, the first volume in a three volume set, summarizes the results of a study performed by the DELTA (Developing European Learning through Technological Advance) Unit in parallel with the projects underway in the research and development Exploratory Action. The report identifies the key issues, associated requirements and options, and…

  17. A review of nuclear thermal propulsion carbide fuel corrosion and key issues

    NASA Technical Reports Server (NTRS)

    Pelaccio, Dennis G.; El-Genk, Mohamed S.

    1994-01-01

    Corrosion (mass loss) of carbide nuclear fuels due to their exposure to hot hydrogen in nuclear thermal propulsion engine systems greatly impacts the performance, thrust-to-weight and life of such systems. This report provides an overview of key issues and processes associated with the corrosion of carbide materials. Additionally, past pertinent development reactor test observations, as well as related experimental work and analysis modeling efforts are reviewed. At the conclusion, recommendations are presented, which provide the foundation for future corrosion modeling and verification efforts.

  18. The Value Added National Project. Technical Report: Primary 4. Value-Added Key Stage 1 to Key Stage 2.

    ERIC Educational Resources Information Center

    Tymms, Peter

    This is the fourth in a series of technical reports that have dealt with issues surrounding the possibility of national value-added systems for primary schools in England. The main focus has been on the relative progress made by students between the ends of Key Stage 1 (KS1) and Key Stage 2 (KS2). The analysis has indicated that the strength of…

  19. Eddy covariance and lysimeter measurements of moisture fluxes over supraglacial debris

    NASA Astrophysics Data System (ADS)

    Brock, Benjamin

    2015-04-01

    Supraglacial debris covers have the potential to evaporate large quantities of water derived from either sub-debris ice melt or precipitation. Currently, knowledge of evaporation and condensation rates in supraglacial debris is limited due to the difficulty of making direct measurements. This paper presents eddy covariance and lysimeter measurements of moisture fluxes made over a 0.2 m debris layer at Miage debris covered glacier, Italian Alps, during the 2013 ablation season. The meteorological data are complimented by reflectometer measurements of volumetric water fraction in the saturated and vadose zones of the debris layer. The lysimeters were designed specifically to mimic the debris cover and were embedded within the debris matrix, level with the surface. Over the ablation season, the latent heat flux is dominated by evaporation, and the flux magnitude closely follows the daily cycle of daytime solar heating and night time radiative cooling of debris. Mean flux values are of the order of 1 kg m-2 day-1, but often higher for short periods following rainfall. Condensation rates are relatively small and restricted to night time and humid conditions when the debris-atmosphere vapour pressure gradient reverses due to relatively warm air overlying cold debris. The reflectometer measurements provide evidence of vertical water movement through capillary rise in the upper part of the fine-grained debris layer, just above the saturated horizon, and demonstrate how debris bulk water content increases after rainfall. The latent heat flux responds directly to changes in wind speed, indicating that atmospheric turbulence can penetrate porous upper debris layers to the saturated horizon. Hence, vertical sorting of debris sediments and antecedent rainfall are important in determining evaporation rates, in addition to current meteorological conditions. Comparison of lysimeter measurements with rainfall data provides an estimate that between 45% and 89% of rainfall is evaporated directly back to the atmosphere. Rainfall evaporation rates increase with debris impermeability and temperature, with highest rates occurring when a shower falls on hot debris. If these point measurements are representative of larger scales, evaporation rates of the order of 1000 tonnes km-2 day-1 are implied, with higher rates following rainfall. This has important implications for downstream runoff, sub-debris ice melt rates (due to consumption of evaporative latent heat energy) and, possibly, convective atmospheric processes.

  20. Comparison of narrow-band reflectance spectroscopy and tristimulus colorimetry for measurements of skin and hair color in persons of different biological ancestry.

    PubMed

    Shriver, M D; Parra, E J

    2000-05-01

    We have used two modern computerized handheld reflectometers, the Photovolt ColorWalk colorimeter (a tristimulus colorimeter; Photovolt, UMM Electronics, Indianapolis, IN) and the DermaSpectrometer (a specialized narrow-band reflectometer; Cortex Technology, Hadsund, Denmark), to compare two methods for the objective determination of skin and hair color. These instruments both determine color by measuring the intensity of reflected light of particular wavelengths. The Photovolt ColorWalk instrument does so by shining a white light and sensing the intensity of the reflected light with a linear photodiode array. The ColorWalk results can then be expressed in terms of several standard color systems, most importantly, the Commission International d'Eclairage (CIE) Lab system, in which any color can be described by three values: L*, the lightness; a*, the amount of green or red; and b*, the amount of yellow or blue. Instead of a white light and photodiodes, the DermaSpectrometer uses two light-emitting diodes (LEDs), one green and one red, to illuminate a surface, and then it records the intensity of the reflected light. The results of these readings are expressed in terms of erythema (E) and melanin (M) indices. We measured the unexposed skin of the inner upper arm, the exposed skin of the forehead, and the hair, of 80 persons using these two instruments. Since it is important for the application of these measures in anthropology that we understand their relationship across a number of different pigmentation levels, we sampled persons from several different groups, namely, European Americans (n = 55), African Americans (n = 9), South Asians (n = 7), and East Asians (n = 9). In these subjects, there is a very high correlation between L* and the M index for the inner arm (R(2) = 0.928, P < 0.001), the forehead (R(2) = 0.822, P < 0.001), and the hair (R(2) = 0.827, P < 0.001). The relationship between a* and the E index is complex and dependent on the pigmentation level. We conclude that while both types of instruments provide accurate estimates of pigment level in skin and hair, measurements using narrow-band instruments may be less affected by the greater redness of certain body sites due to increased vascularization. Copyright 2000 Wiley-Liss, Inc.

  1. Issues for eHealth in Psychiatry: Results of an Expert Survey.

    PubMed

    Nicholas, Jennifer; Huckvale, Kit; Larsen, Mark Erik; Basu, Ashna; Batterham, Philip J; Shaw, Frances; Sendi, Shahbaz

    2017-02-28

    Technology has changed the landscape in which psychiatry operates. Effective, evidence-based treatments for mental health care are now available at the fingertips of anyone with Internet access. However, technological solutions for mental health are not necessarily sought by consumers nor recommended by clinicians. The objectives of this study are to identify and discuss the barriers to introducing eHealth technology-supported interventions within mental health. An interactive polling tool was used to ask "In this brave new world, what are the key issues that need to be addressed to improve mental health (using technology)?" Respondents were the multidisciplinary attendees of the "Humans and Machines: A Quest for Better Mental Health" conference, held in Sydney, Australia, in 2016. Responses were categorized into 10 key issues using team-based qualitative analysis. A total of 155 responses to the question were received from 66 audience members. Responses were categorized into 10 issues and ordered by importance: access to care, integration and collaboration, education and awareness, mental health stigma, data privacy, trust, understanding and assessment of mental health, government and policy, optimal design, and engagement. In this paper, each of the 10 issues are outlined, and potential solutions are discussed. Many of the issues were interrelated, having implications for other key areas identified. As many of the issues identified directly related to barriers to care, priority should be given to addressing these issues that are common across mental health delivery. Despite new challenges raised by technology, technology-supported mental health interventions represent a tremendous opportunity to address in a timely way these major concerns and improve the receipt of effective, evidence-based therapy by those in need. ©Jennifer Nicholas, Kit Huckvale, Mark Erik Larsen, Ashna Basu, Philip J Batterham, Frances Shaw, Shahbaz Sendi. Originally published in the Journal of Medical Internet Research (http://www.jmir.org), 28.02.2017.

  2. Supporting interoperability of collaborative networks through engineering of a service-based Mediation Information System (MISE 2.0)

    NASA Astrophysics Data System (ADS)

    Benaben, Frederick; Mu, Wenxin; Boissel-Dallier, Nicolas; Barthe-Delanoe, Anne-Marie; Zribi, Sarah; Pingaud, Herve

    2015-08-01

    The Mediation Information System Engineering project is currently finishing its second iteration (MISE 2.0). The main objective of this scientific project is to provide any emerging collaborative situation with methods and tools to deploy a Mediation Information System (MIS). MISE 2.0 aims at defining and designing a service-based platform, dedicated to initiating and supporting the interoperability of collaborative situations among potential partners. This MISE 2.0 platform implements a model-driven engineering approach to the design of a service-oriented MIS dedicated to supporting the collaborative situation. This approach is structured in three layers, each providing their own key innovative points: (i) the gathering of individual and collaborative knowledge to provide appropriate collaborative business behaviour (key point: knowledge management, including semantics, exploitation and capitalisation), (ii) deployment of a mediation information system able to computerise the previously deduced collaborative processes (key point: the automatic generation of collaborative workflows, including connection with existing devices or services) (iii) the management of the agility of the obtained collaborative network of organisations (key point: supervision of collaborative situations and relevant exploitation of the gathered data). MISE covers business issues (through BPM), technical issues (through an SOA) and agility issues of collaborative situations (through EDA).

  3. Painful Joints? Early Treatment for Rheumatoid Arthritis Is Key

    MedlinePlus

    ... Print this issue Painful Joints? Early Treatment for Rheumatoid Arthritis Is Key En español Send us your comments ... type of arthritis. It’s far more common than rheumatoid arthritis. Osteoarthritis is caused by wear and tear on ...

  4. Public Key Infrastructure Study

    DTIC Science & Technology

    1994-04-01

    commerce. This Public Key Infrastructure (PKI) study focuses on the United States Federal Government operations, but also addresses national and global ... issues in order to facilitate the interoperation of protected electronic commerce among the various levels of government in the U.S., private citizens

  5. Textual analysis of tobacco editorials: how are Key media gatekeepers framing the issues?

    PubMed

    Smith, Katherine Clegg; Wakefield, Melanie

    2005-01-01

    The news media's potential to promote awareness of health issues is established, and media advocacy is now an important tool in combating tobacco use. This study examines newspaper editors' perspectives of tobacco-related issues. This study presents a textual analysis of tobacco-related editorials. The data consist of editorials on tobacco from a sample of 310 U.S. daily newspapers over the course of 1 year (2001). Data were sampled from a random one-third of the days per month, yielding 162 editorials for analysis. A qualitative textual analysis was conducted. Each editorial was coded for theme, position, and frame. We analyzed the topics gaining editorial attention and the arguments made to support various perspectives. Editorials discussed a variety of both positive and negative news events, largely conveying support for tobacco-control objectives. Various organizing frames were used-supporting policy interventions, condemning the industry, highlighting individual rights, and expressing general cynicism were most prevalent. Editors largely promoted tobacco-control efforts, particularly policy advances. There was, however, little coverage of key issues such as health effects and addiction-perhaps because they are no longer perceived to be contentious. Advocates should seek to address this area and minimize the cynicism of key media gatekeepers to avoid undermining policy and individual change efforts.

  6. Workplace exposure to engineered nanomaterials: the Italian path for the definition of occupational health and safety policies.

    PubMed

    Mirabile, Marco; Boccuni, Fabio; Gagliardi, Diana; Rondinone, Bruna Maria; Iavicoli, Sergio

    2014-07-01

    This study explores the way the publication of a National White Book on health and safety risks that affect workers in jobs involving Nanotechnologies and Nanomaterials influenced the key Italian stakeholders attitude toward this issue and identifies the standpoints and priorities shared among researchers and stakeholders to develop a policy framework to address this issue. The study not only highlights some important assumptions (i.e. the acknowledgment by the key stakeholders of the need for actions and the identification of objectives which can gain a wide consensus) for the establishment of a policy community that sustains the development of a policymaking process on the issue but, through the interaction between stakeholders and OSH researchers, it also identifies some in nuce proposals that represent the starting point for policy interventions aimed at meeting the needs of both stakeholders and scientific community. Results obtained in terms of clarification of interests at stake, identification of potential areas of consensus and level of key national actors' engagement achieved, show the potentialities of adopting a knowledge based and inclusive approach to policy-making to address the issue of prevention and management of health and safety risks related to technological innovation within a framework of scientific uncertainty. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  7. DOT's budget : management and performance issues facing the department in fiscal year 1999

    DOT National Transportation Integrated Search

    1998-02-12

    This testimony discusses key resource management issues and performance challenges facing the Department of Transportation in 1999 and beyond. 1. There is a need for increased management attention to highway, transit, and rail programs - which accoun...

  8. Understanding Cost-Effectiveness of Energy Efficiency Programs: Best Practices, Technical Methods, and Emerging Issues for Policy-Makers

    EPA Pesticide Factsheets

    Reviews the issues and approaches involved in considering and adopting cost-effectiveness tests for energy efficiency, including discussing each perspective represented by the five standard cost-effectiveness tests and clarifying key terms.

  9. ISSUES IN SEDIMENT TOXICITY AND ECOLOGICAL RISK ASSESSMENT

    EPA Science Inventory

    This paper is based on a facilitated Workshop and Roundtable Discussion of key issues in sediment toxicology and ecological risk assessment (ERA) as applied to sediments that was held at the Conference on Dredged Material Management: Options and Environmental Considerations. The ...

  10. Adolescent Literacy

    ERIC Educational Resources Information Center

    Ippolito, Jacy, Ed.; Steele, Jennifer L., Ed.; Samson, Jennifer F., Ed.

    2012-01-01

    "Adolescent Literacy" initially appeared as a special issue of the "Harvard Educational Review". It explores key issues and debates in the adolescent literacy crisis, the popular use of cognitive strategies, and disciplinary and content-area literacy. Also examined are alternative forms of literacy, afterschool interventions, new instruction…

  11. Model of the Students' Key Competences Development through Interactive Whiteboard in the Subject of Technology

    ERIC Educational Resources Information Center

    Brecka, Peter; Valentová, Monika

    2017-01-01

    The basis of the submitted study are the continuously rising demands to alter the curricula with the aim to develop students' key competences in order to increase their professional versatility. The lack of scientific research and discussions show that little investigation has been done on the issue of development of key competences. Therefore,…

  12. Teaching and Studying Social Issues: Major Programs and Approaches. Research in Curriculum and Instruction

    ERIC Educational Resources Information Center

    Totten, Samuel, Ed.; Pedersen, Jon, Ed.

    2010-01-01

    "Teaching and Studying Social Issues: Major Programs and Approaches" focuses on many of the major innovations developed over the past 100 years by noted educators to assist students in the study and analysis of key social issues that impact their lives and society. This book complements earlier books that address other aspects of studying and…

  13. 77 FR 30508 - Open Meeting To Obtain Input for 2013 DoD 10 Key State Issues Impacting Service Members and Their...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-05-23

    ... State Issues Impacting Service Members and Their Families AGENCY: Department of Defense. ACTION: Notice. SUMMARY: The public is invited to attend an open session to consider issues impacting Service members and their families that can best be resolved by state governments. Additionally, the public is invited to...

  14. The burgeoning science of genetics and the impact on public policy.

    PubMed

    Hatch, Orrin G

    2004-01-01

    The legislative branch of government often wrestles with the challenges of public policy issues in the health care area that raise multi-dimensional questions that cut across disciplines of science, law, economics, and ethics. Sometimes the purely scientific issues can be confounding by themselves. This article highlights some key policy issues that require consideration in the post-genome era.

  15. Developing Communities of Enquiry: Dealing with Social and Ethical Issues in Science at Key Stage 3

    ERIC Educational Resources Information Center

    Dunlop, Lynda; Humes, Gill; Clarke, Linda; Martin, Valerie McKelvey

    2011-01-01

    Reproductive technologies, drug discovery and exploration of the universe are areas of contemporary research that raise issues for individuals and society. Forward Thinking, Northern Ireland uses the development of communities of enquiry to promote discussion of these and other social and ethical issues in science with students aged 11-14 years.…

  16. Language Policy in Education and Its Affect in Cyprus Issues on the Development of Identity and Interethnic Relationships

    ERIC Educational Resources Information Center

    Karmellou, Christalla

    2008-01-01

    The paper discusses educational and language policy issues within the context of the Greek Cypriot education as prescribed by the constitutional provisions of the 1960s settlement. In view of the prospect of unification in Cyprus, the author examines the role of language educational policy in future peace building. Key issues regarding ethnic…

  17. College and Career Readiness: K-12 and Higher Education Collaborating for Student Success. coNCepts. Issue 5, Jan 2014

    ERIC Educational Resources Information Center

    Harris, Buddy

    2014-01-01

    "coNCepts" is a state-specific policy primer of The Hunt Institute. Each issue focuses on a critical topic in education policy, highlights key research for North Carolina policymakers, and prompts discussion of solutions. This issue begins by describing North Carolina's economy as having experienced a remarkable transformation during the…

  18. Stakeholders' views on ethical issues in the practice of in-vitro fertilisation and embryo transfer in Nigeria.

    PubMed

    Ajayi, R A; Dibosa-Osadolor, O J

    2011-09-01

    The provision of IVF for the specialized treatment of infertility has grown very rapidly in Nigeria in recent times, especially within the private sector. The objective of this study was to document the views of key stakeholders regarding salient ethical issues relating to the practice of in-vitro fertilisation (IVF) in Nigeria. A think-tank session was convened with participants drawn from different backgrounds and disciplines to deliberate on ethical issues in IVF. Ten key issues were discussed at this inaugural session. It was unanimously agreed that there are no right or wrong answers when considering the ethics and morality of IVF as these are principally dependent on choice and circumstances. However within the legal and socio-cultural dictates of the Nigerian society, right and wrong may be clearly determined on some issues. With the expansion of the IVF industry and technology in Nigeria, the need to address related ethical issues have become paramount. The forum recommended that it is important that regulatory guidelines are put in place to regulate the practice of IVF in Nigeria and to protect patients' rights and safety.

  19. Wireless technologies and accessibility for people with disabilities: findings from a policy research instrument.

    PubMed

    Baker, Paul M A; Moon, Nathan W

    2008-01-01

    The near universal deployment in the United States of a wide variety of information and communications technologies, both wired and wireless, creates potential barriers to use for several key populations, including the poor, people with disabilities, and the aging. Equal access to wireless technologies and services can be achieved through a variety of mechanisms, including legislation and regulations, market-based solutions, and awareness and outreach-based approaches. This article discusses the results of policy research conducted by the Rehabilitation Engineering Research Center on Wireless Technologies (Wireless RERC) using policy Delphi polling methodology to probe stakeholders' opinions on key access barrier issues and to explore potential policy responses. Participants included disability advocates, disability/wireless technology policy makers, and product developers/manufacturers. Respondent input informed subsequent development of potential policy initiatives to increase access to these technologies. The findings from the Delphi suggest that awareness issues remain most important, especially manufacturer awareness of user needs and availability of consumer information for selecting the most appropriate wireless devices and services. Other key issues included the ability of people with disabilities to afford technologies and inadequacies in legislation and policy making for ensuring their general accessibility, as well as usefulness in emergencies. Technical issues, including interoperability, speech-to-text conversion, and hearing aid compatibility, were also identified by participating stakeholders as important. To address all these issues, Delphi respondents favored goals and options congruent with voluntary market-driven solutions where possible but also supported federal involvement, where necessary, to aid this process.

  20. Human Health Effects of Biphenyl: Key Findings and Scientific Issues

    PubMed Central

    Li, Zheng; Hogan, Karen A.; Cai, Christine; Rieth, Susan

    2015-01-01

    Background: In support of the Integrated Risk Information System (IRIS), the U.S. Environmental Protection Agency (EPA) has evaluated the human health hazards of biphenyl exposure. Objectives: We review key findings and scientific issues regarding expected human health effects of biphenyl. Methods: Scientific literature from 1926 through September 2012 was critically evaluated to identify potential human health hazards associated with biphenyl exposure. Key issues related to the carcinogenicity and noncancer health hazards of biphenyl were examined based on evidence from experimental animal bioassays and mechanistic studies. Discussion: Systematic consideration of experimental animal studies of oral biphenyl exposure took into account the variety of study designs (e.g., study sizes, exposure levels, and exposure durations) to reconcile differing reported results. The available mechanistic and toxicokinetic evidence supports the hypothesis that male rat urinary bladder tumors arise through urinary bladder calculi formation but is insufficient to hypothesize a mode of action for liver tumors in female mice. Biphenyl and its metabolites may induce genetic damage, but a role for genotoxicity in biphenyl-induced carcinogenicity has not been established. Conclusions: The available health effects data for biphenyl provides suggestive evidence for carcinogenicity in humans, based on increased incidences of male rat urinary bladder tumors at high exposure levels and on female mouse liver tumors. Kidney toxicity is also a potential human health hazard of biphenyl exposure. Citation: Li Z, Hogan KA, Cai C, Rieth S. 2016. Human health effects of biphenyl: key findings and scientific issues. Environ Health Perspect 124:703–712; http://dx.doi.org/10.1289/ehp.1509730 PMID:26529796

  1. Implementation science approaches for integrating eHealth research into practice and policy.

    PubMed

    Glasgow, Russell E; Phillips, Siobhan M; Sanchez, Michael A

    2014-07-01

    To summarize key issues in the eHealth field from an implementation science perspective and to highlight illustrative processes, examples and key directions to help more rapidly integrate research, policy and practice. We present background on implementation science models and emerging principles; discuss implications for eHealth research; provide examples of practical designs, measures and exemplar studies that address key implementation science issues; and make recommendations for ways to more rapidly develop and test eHealth interventions as well as future research, policy and practice. The pace of eHealth research has generally not kept up with technological advances, and many of our designs, methods and funding mechanisms are incapable of providing the types of rapid and relevant information needed. Although there has been substantial eHealth research conducted with positive short-term results, several key implementation and dissemination issues such as representativeness, cost, unintended consequences, impact on health inequities, and sustainability have not been addressed or reported. Examples of studies in several of these areas are summarized to demonstrate this is possible. eHealth research that is intended to translate into policy and practice should be more contextual, report more on setting factors, employ more responsive and pragmatic designs and report results more transparently on issues important to potential adopting patients, clinicians and organizational decision makers. We outline an alternative development and assessment model, summarize implementation science findings that can help focus attention, and call for different types of more rapid and relevant research and funding mechanisms. Published by Elsevier Ireland Ltd.

  2. A Round-Efficient Authenticated Key Agreement Scheme Based on Extended Chaotic Maps for Group Cloud Meeting.

    PubMed

    Lin, Tsung-Hung; Tsung, Chen-Kun; Lee, Tian-Fu; Wang, Zeng-Bo

    2017-12-03

    The security is a critical issue for business purposes. For example, the cloud meeting must consider strong security to maintain the communication privacy. Considering the scenario with cloud meeting, we apply extended chaotic map to present passwordless group authentication key agreement, termed as Passwordless Group Authentication Key Agreement (PL-GAKA). PL-GAKA improves the computation efficiency for the simple group password-based authenticated key agreement (SGPAKE) proposed by Lee et al. in terms of computing the session key. Since the extended chaotic map has equivalent security level to the Diffie-Hellman key exchange scheme applied by SGPAKE, the security of PL-GAKA is not sacrificed when improving the computation efficiency. Moreover, PL-GAKA is a passwordless scheme, so the password maintenance is not necessary. Short-term authentication is considered, hence the communication security is stronger than other protocols by dynamically generating session key in each cloud meeting. In our analysis, we first prove that each meeting member can get the correct information during the meeting. We analyze common security issues for the proposed PL-GAKA in terms of session key security, mutual authentication, perfect forward security, and data integrity. Moreover, we also demonstrate that communicating in PL-GAKA is secure when suffering replay attacks, impersonation attacks, privileged insider attacks, and stolen-verifier attacks. Eventually, an overall comparison is given to show the performance between PL-GAKA, SGPAKE and related solutions.

  3. Enhancing security and improving interoperability in healthcare information systems.

    PubMed

    Gritzalis, D A

    1998-01-01

    Security is a key issue in healthcare information systems, since most aspects of security become of considerable or even critical importance when handling healthcare information. In addition, the intense need for information exchange has revealed interoperability of systems and applications as another key issue. Standardization can play an important role towards both these issues. In this paper, relevant standardization activities are briefly presented, and existing and emerging healthcare information security standards are identified and critically analysed. The analysis is based on a framework which has been developed for this reason. Therefore, the identification of gaps and inconsistencies in current standardization, the description of the conflicts of standards with legislation, and the analysis of implications of these standards to user organizations, are the main results of this paper.

  4. A broader view of marketing: implications for surgeons.

    PubMed

    Kelley, Scott W; Schwartz, Richard W

    2004-12-01

    The health care sector of the economy is changing. There is unprecedented growth in the health care sector, and competitive forces have a more prominent role. In addition, consumers have become more informed and as a result, more empowered. Patients in the health care sector are no exception to this trend. As patients become more informed, it is imperative that health care providers become more effective at marketing their services. In general, physicians typically have received little training in the field of marketing, which results in potentially limited understanding of the key marketing issues being faced in today's health care environment. We identify and examine several key marketing issues critical to the success of health care providers in today's environment. Further, we offer some managerial recommendations designed to address each of these issues.

  5. Clinical Issues-November 2017.

    PubMed

    Johnstone, Esther M

    2017-11-01

    Heating, ventilation, and air-conditioning (HVAC) systems in the OR Key words: airborne contaminants, HVAC system, air pressure, air quality, temperature and humidity. Air changes and positive pressure Key words: air changes, positive pressure airflow, unidirectional airflow, outdoor air, recirculated air. Product selection Key word: product evaluation, product selection, selection committee. Entry into practice Key words: associate degree in nursing, bachelor of science in nursing, entry-level position, advanced education, BSN-prepared RNs. Mentoring in perioperative nursing Key words: mentor, novice, practice improvement, nursing workforce. Copyright © 2017 AORN, Inc. Published by Elsevier Inc. All rights reserved.

  6. Finding the Key to a Good Theatre Program: Some Comments on the ETA Survey.

    ERIC Educational Resources Information Center

    Hobgood, Burnet M.

    1991-01-01

    Offers some comments on the Educational Theatre Association's survey on the status of theater in U.S. high schools in the same issue of this journal. Discusses finding the key factors responsible for good school theater. (PRA)

  7. Qualitative Approaches to Research in Counselling and Psychotherapy: Issues and Challenges.

    ERIC Educational Resources Information Center

    McLeod, John

    1996-01-01

    Discusses key issues which address the distinctive dilemmas and challenges associated with qualitative approaches to evaluating counseling. Investigates such concerns as relationships with research participants, ethics, reflexivity, methodological choice, communicability, perspective, and obviousness. Makes some suggestions regarding the link…

  8. EXPERIMENTAL INVESTIGATION OF CRITICAL FUNDAMENTAL ISSUES IN HAZARDOUS WASTE INCINERATION

    EPA Science Inventory

    The report gives results of a laboratory-scale program investigating several fundamental issues involved in hazardous waste incineration. The key experiment for each study was the measurement of waste destruction behavior in a sub-scale turbulent spray flame. (1) Atomization Qual...

  9. An investigation of how university sports team athletic therapists and physical therapists experience ethical issues.

    PubMed

    Riendeau, Catherine; Parent-Houle, Valérie; Lebel-Gabriel, Marie Eve; Gauvin, Patrick; Liu, Le Yu; Pearson, Isabelle; Hunt, Matthew R

    2015-03-01

    Qualitative study using interpretive description methodology. The purpose of this study was to better understand how ethical issues are experienced by university sports team athletic therapists and physical therapists. In clinical practice, sports teams are associated with a range of ethical issues. Issues commonly reported in the literature include confidentiality, return-to-play decisions, conflicts of interest, advertising, doping, and use of local anesthetic. To date, there has been limited examination of how athletic therapists and physical therapists involved with sports teams experience these ethical issues, and limited exploration of how these ethical issues, when encountered, are shaped by therapists' professional roles and responsibilities. Semi-structured interviews were conducted with 11 athletic or physical therapists working with sports teams in 5 Canadian provinces. The data were analyzed inductively, using a recursive approach and constant comparative techniques. Four key themes were developed relating to the participants' experiences of ethical issues: establishing and maintaining professional boundaries, striving for respectful and effective collaboration, seeking answers to ethical concerns, and living with the repercussions of challenging decisions. While many ethical issues reported by participants resemble those faced by sports medicine physicians, they are experienced in distinctive ways, due to differences in professional roles and identities. Issues concerning professional boundaries were also more prominent for the study participants than the literature has reported them to be for sports medicine physicians. Effective communication and enhanced collaboration appear to be key elements in managing these ethical challenges.

  10. Fuels irradiation testing for the SP-100 program

    NASA Technical Reports Server (NTRS)

    Makenas, Bruce J.; Hales, Janell W.; Ward, Alva L.

    1991-01-01

    An SP-100 fuel pin irradiation testing program is well on the way to providing data for performance correlations and demonstrating the lifetime and safety of the fuel system of the compact lithium-cooled reactor. Key SP-100 fuel performance issues addressed are the need for low fuel swelling and low fission gas release to minimize cladding strain, and the need for barrier integrity to prevent fuel/cladding chemical interaction. This paper provides a description of the irradiation test program that addresses these key issues and summarizes recent results of posttest examinations including data obtained at 6 atom percent goal burnup.

  11. Key issues concerning environmental enrichment for laboratory-held fish species.

    PubMed

    Williams, T D; Readman, G D; Owen, S F

    2009-04-01

    An improved knowledge and understanding of the fundamental biological requirements is needed for many of the species of fish held in captivity and, without this knowledge it is difficult to determine the optimal conditions for laboratory culture. The aim of this paper is to review the key issues concerning environmental enrichment for laboratory-held fish species and identify where improvements are required. It provides background information on environmental enrichment, describes enrichment techniques currently used in aquatic ecotoxicology studies, identifies potential restrictions in their use and discusses why more detailed and species-specific guidance is needed.

  12. Determining potential 30/20 GHZ domestic satellite system concepts and establishment of a suitable experimental configuration

    NASA Technical Reports Server (NTRS)

    Stevens, G. H.; Anzic, G.

    1979-01-01

    NASA is conducting a series of millimeter wave satellite communication systems and market studies to: (1) determine potential domestic 30/20 GHz satellite concepts and market potential, and (2) establish the requirements for a suitable technology verification payload which, although intended to be modest in capacity, would sufficiently demonstrate key technologies and experimentally address key operational issues. Preliminary results and critical issues of the current contracted effort are described. Also included is a description of a NASA-developed multibeam satellite payload configuration which may be representative of concepts utilized in a technology flight verification program.

  13. Key Issues in Hymenoptera Venom Allergy: An Update.

    PubMed

    Alfaya Arias, T; Soriano Gómis, V; Soto Mera, T; Vega Castro, A; Vega Gutiérrez, J M; Alonso Llamazares, A; Antolín Amérigo, D; Carballada Gonzalez, F J; Dominguez Noche, C; Gutierrez Fernandez, D; Marques Amat, L; Martinez Arcediano, A; Martinez San Ireneo, M; Moreno Ancillo, A; Puente Crespo, Y; Ruiz Leon, B; Sánchez Morillas, L

    In this review, the Hymenoptera Allergy Committee of the SEAIC analyzes the most recent scientific literature addressing problems related to the diagnosis of hymenoptera allergy and to management of venom immunotherapy. Molecular diagnosis and molecular risk profiles are the key areas addressed. The appearance of new species of hymenoptera that are potentially allergenic in Spain and the associated diagnostic and therapeutic problems are also described. Finally, we analyze the issue of mast cell activation syndrome closely related to hymenoptera allergy, which has become a new diagnostic challenge for allergists given its high prevalence in patients with venom anaphylaxis.

  14. Thin film cell development workshop report

    NASA Technical Reports Server (NTRS)

    Woodyard, James R.

    1991-01-01

    The Thin Film Development Workshop provided an opportunity for those interested in space applications of thin film cells to debate several topics. The unique characteristics of thin film cells as well as a number of other issues were covered during the discussions. The potential of thin film cells, key research and development issues, manufacturing issues, radiation damage, substrates, and space qualification of thin film cells were discussed.

  15. USSR Space Life Sciences Digest. Index to issues 5-9

    NASA Technical Reports Server (NTRS)

    Hooke, Lydia Razran

    1987-01-01

    An index to issues 5 through 9 of the USSR Space Life Sciences Digest is provided in two sections. The first section lists bibliographic citations of abstracts contained in the Digest issues covered, grouped by topic area categories. Cross references to other relevant abstracts in different categories are also provided. The second section provides a key word index for the same set of abstracts.

  16. Examining Key Issues Underlying the Audit Commission Reports on SEN Policy Paper 1 (5th Series)

    ERIC Educational Resources Information Center

    Norwich, Brahm; Beek, Chris; Richardson, Penny; Gray, Peter

    2004-01-01

    This book is the first publication in the fifth series of seminars organised by the SEN Policy Options Steering Group to examine policy issues to do with special educational needs. The aim of the seminar was to examine in depth several underlying issues raised by the recent Audit Commission Reports on special educational needs. The seminar…

  17. Why Minimal Multiple Rules Provide a Unique Window into UG and L2

    ERIC Educational Resources Information Center

    Amaral, Luiz; Roeper, Tom

    2014-01-01

    This article clarifies some ideas presented in this issue's keynote article (Amaral and Roeper, this issue) and discusses several issues raised by the contributors' comments on the nature of the Multiple Grammars (MG) theory. One of the key goals of the article is to unequivocally state that MG is not a parametric theory and that its…

  18. Key Skills and Competencies. Symposium.

    ERIC Educational Resources Information Center

    2002

    This document contains three papers on key skills and competencies and human resource development (HRD). "Career Related Competencies" (Marinka A.C.T. Kuijpers) reports findings from surveys completed by Dutch employees who identified these issues: self-reflection is more important than career control; age and gender influence attitude…

  19. School Leadership in the Caribbean: Perceptions, Practices, Paradigms

    ERIC Educational Resources Information Center

    Miller, Paul, Ed.

    2013-01-01

    Successful school leadership is an issue currently being debated up and down Caribbean territories. Key issues in the ongoing debate include: students' outcomes and participation in the regional Caribbean Secondary Examinations (CSEC); teacher recruitment and retention; teacher training and continuing professional development (upgrading); and…

  20. Outlook. Number 364

    ERIC Educational Resources Information Center

    Council for American Private Education, 2011

    2011-01-01

    Council for American Private Education (CAPE) is a coalition of national associations serving private schools K-12. "Outlook" is published monthly by CAPE. This issue contains the following articles: (1) House Approves Opportunity Scholarships Bill; (2) Lawmakers Discuss Key Issues at CAPE Forum; (3) Digital Now; and (4) CAPE Notes.

  1. Extrinsic and Intrinsic Motivation at 30: Unresolved Scientific Issues

    ERIC Educational Resources Information Center

    Reiss, Steven

    2005-01-01

    The undermining effect of extrinsic reward on intrinsic motivation remains unproven. The key unresolved issues are construct invalidity (all four definitions are unproved and two are illogical); measurement unreliability (the free-choice measure requires unreliable, subjective judgments to infer intrinsic motivation); inadequate experimental…

  2. Public Engagement. IDRA Focus.

    ERIC Educational Resources Information Center

    IDRA Newsletter, 1996

    1996-01-01

    This newsletter includes six articles that examine key issues facing public schools and communities related to accountability, bilingual education, immigrant education, school finance, and school choice. In addressing these issues, articles focus on the importance of community involvement and input in local school reform efforts aimed at achieving…

  3. Serving the Public Good

    ERIC Educational Resources Information Center

    Greene, Jennifer C.

    2010-01-01

    This discussion foregrounds four key issues engaged by the articles presented in this special issue: the unique challenges and opportunities of environmental education evaluation, how to think well about the evaluation approaches and purposes that best match this domain, evaluation capacity building in environmental education and action, and…

  4. Major Issues Facing the Conservation Movement in the Coming Decade and Beyond.

    ERIC Educational Resources Information Center

    Strong, Maurice

    1984-01-01

    The key issues facing the conservation movement may be grouped into three areas: (1) threats to human health; (2) threats to food and fuel supplies; and (3) long-term threats to the biosphere. Each of these areas is discussed. (JN)

  5. Policy Update. IDRA Focus.

    ERIC Educational Resources Information Center

    IDRA Newsletter, 1995

    1995-01-01

    This theme issue focuses on the drastic revision of the Texas education code undertaken during the 1995 state legislative session. "Education Policy Reform: Key Points for Districts" (Albert Cortez, Mikki Symonds) outlines critical issues in the legislation that have an impact on educational quality: charter schools exempt from state…

  6. Notes on Linguistics, 1990.

    ERIC Educational Resources Information Center

    Notes on Linguistics, 1990

    1990-01-01

    This document consists of the four issues of "Notes on Linguistics" published during 1990. Articles in the four issues include: "The Indians Do Say Ugh-Ugh" (Howard W. Law); "Constraints of Relevance, A Key to Particle Typology" (Regina Blass); "Whatever Happened to Me? (An Objective Case Study)" (Aretta…

  7. Clinical Issues-May 2016.

    PubMed

    Van Wicklin, Sharon A

    2016-05-01

    Variations in documenting surgical wound classification Key words: surgical wound classification, clean, clean-contaminated, contaminated, dirty. Wearing long-sleeved jackets while preparing and packaging items for sterilization Key words: long-sleeved jackets, organic material, sterile processing. Endoscopic transmission of prions Key words: prions, high-risk tissue, low-risk tissue, Creutzfeldt-Jakob disease (CJD), variant Creutzfeldt-Jakob disease (vCJD). Wearing gloves when handling flexible endoscopes Key words: gloves, low-protein, powder-free, natural rubber latex gloves, latex-free gloves. Copyright © 2016 AORN, Inc. Published by Elsevier Inc. All rights reserved.

  8. Annual Report To Congress. Department of Energy Activities Relating to the Defense Nuclear Facilities Safety Board, Calendar Year 2003

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None, None

    2004-02-28

    The Department of Energy (Department) submits an Annual Report to Congress each year detailing the Department’s activities relating to the Defense Nuclear Facilities Safety Board (Board), which provides advice and recommendations to the Secretary of Energy (Secretary) regarding public health and safety issues at the Department’s defense nuclear facilities. In 2003, the Department continued ongoing activities to resolve issues identified by the Board in formal recommendations and correspondence, staff issue reports pertaining to Department facilities, and public meetings and briefings. Additionally, the Department is implementing several key safety initiatives to address and prevent safety issues: safety culture and review ofmore » the Columbia accident investigation; risk reduction through stabilization of excess nuclear materials; the Facility Representative Program; independent oversight and performance assurance; the Federal Technical Capability Program (FTCP); executive safety initiatives; and quality assurance activities. The following summarizes the key activities addressed in this Annual Report.« less

  9. GAIA - A New Approach To Decision Making on Climate Disruption Issues

    NASA Astrophysics Data System (ADS)

    Paxton, L. J.; Weiss, M.; Schaefer, R. K.; Swartz, W. H.; Nix, M.; Strong, S. B.; Fountain, G. H.; Babin, S. M.; Pikas, C. K.; Parker, C. L.; Global Assimilation of InformationAction

    2011-12-01

    GAIA - the Global Assimilation of Information for Action program - provides a broadly extensible framework for enabling the development of a deeper understanding of the issues associated with climate disruption. The key notion of GAIA is that the global climate problem is so complex that a "system engineering" approach is needed in order to make it understandable. The key tenet of system engineering is to focus on requirements and to develop a cost-effective process for satisfying those requirements. To demonstrate this approach we focused first on the impact of climate disruption on public health. GAIA is described in some detail on our website (http://gaia.jhuapl.edu). Climate disruption is not just a scientific problem; one of the key issues that our community has is that of translating scientific results into knowledge that can be used to make informed decisions. In order to support decision makers we have to understand their issues and how to communicate with them. In this talk, we describe how we have built a community of interest that combines subject matter experts from diverse communities (public health, climate change, government, public policy, industry, etc) with policy makers and representatives from industry to develop, on a "level playing field", an understanding of each other's points of view and issues. The first application of this technology was the development of a workshop on Climate, Climate Change and Public Health held April 12-14, 2011. This paper describes our approach to going beyond the workshop environment to continue to engage the decision maker's community in a variety of ways that translate abstract scientific data into actionable information. Key ideas we will discuss include the development of social media, simulations of global/national/local environments affected by climate disruption, and visualizations of the monetary and health impacts of choosing not to address mitigation or adaptation to climate disruption.

  10. Curriculum Leadership: Development and Implementation

    ERIC Educational Resources Information Center

    Glatthorn, Allan A.; Boschee, Floyd; Whitehead, Bruce M.

    2005-01-01

    This book is a resource written for educational leaders who want to successfully restructure and enhance curriculum in schools today. It provides innovative and successful curriculum ideas, including reflective case studies, "Keys to Leadership" sections, curriculum tips, and "Challenge" sections with key issues and questions in every chapter.…

  11. Political Socialization, Tolerance, and Sexual Identity

    ERIC Educational Resources Information Center

    Avery, Patricia G.

    2002-01-01

    Key concepts in political socialization, tolerance, groups, rights and responsibilities can be used to understand the way in which young people struggle with sexual identity issues. Educators may promote greater tolerance for homosexuality among heterosexuals by situating sexual identity issues within a broader discussion of democratic principles.…

  12. The Student Issue. Original Articles by Student Gammans.

    ERIC Educational Resources Information Center

    Neill, Kweethai C., Ed.

    1997-01-01

    This issue contains eight articles on health education by student members of Eta Sigma Gamma, the National Professional Health Education Honorary. The papers are: (1) "Community Involvement: The Key to Successful Implementation of Comprehensive School Health Education" (Crystal L. Bieterman); (2) "HIV Infection and the Hispanic…

  13. Accommodating the Spectrum of Individual Abilities. Clearinghouse Publication 81.

    ERIC Educational Resources Information Center

    Commission on Civil Rights, Washington, DC.

    The monograph addresses legal issues involving discrimination against handicapped persons and the key legal requirement of reasonable accommodation. Four chapters in Part I examine background issues, including definitions and statistical overviews of handicaps; historical attitudes toward handicapped persons and an analysis of the extent of…

  14. UNESCO Guidelines on Intercultural Education

    ERIC Educational Resources Information Center

    United Nations Educational, Scientific and Cultural Organization (UNESCO), 2007

    2007-01-01

    This paper aims to synthesize the central issues surrounding Intercultural Education, and presents the fundamental guiding principles for an intercultural approach to education as viewed by UNESCO. It is divided into three parts. Part I outlines the key issues surrounding Intercultural Education, as well as its objectives and basic operating…

  15. Native Speakers in Linguistic Imperialism

    ERIC Educational Resources Information Center

    Phillipson, Robert

    2016-01-01

    An investigation of Native English Speaking Teachers' performance in schemes in six Asian contexts, commissioned by the British Council, and undertaken by three British academics, is subjected to critical evaluation. Key issues for exploration are the issue of a monolingual approach to English learning and teaching, and the inappropriate…

  16. A Personal Experience of Supervision.

    ERIC Educational Resources Information Center

    Winter, Pam

    1994-01-01

    The author's personal experience and perspective as a feminist counselor and supervisee is explored. Some key boundary issues are identified which have brought about some important learning for her. These examples illustrate the crucial importance of an awareness of gender issues within both the counseling and the supervisory relationship. (Author)

  17. From Seurat to Snapshots: What the Visual Arts Could Contribute to Education.

    ERIC Educational Resources Information Center

    Duncum, Paul

    1996-01-01

    Advocates reconceptualizing visual arts as a core subject embodying key elements of experiential learning and critical thinking through an interdisciplinary approach. Illustrates this approach with a discussion of the interconnected issues surrounding family snapshots (social history, aesthetics, technological advancement). Discusses issues of…

  18. Internet Issues and Applications, 1997-1998.

    ERIC Educational Resources Information Center

    Dempsey, Bert J., Ed.; Jones, Paul, Ed.

    This book gives an overview of the leading-edge Internet application areas (streaming multimedia, collaborative tools, Web databases) and key information policy issues (privacy, censorship, information quality, and more). The text serves as a primer on understanding the forces--economic, legal, social, as well as technological--that are shaping…

  19. 75 FR 881 - Meeting of Advisory Committee on International Communications and Information Policy

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-01-06

    ... development issues, international spectrum requirements and harmonization, cyber-security, and data protection... will discuss key issues of importance to U.S. communications policy interests including future... Bureau of Diplomatic Security to enhance the Department's security by tracking visitor traffic and to...

  20. New Horizons in Education, 2000.

    ERIC Educational Resources Information Center

    Ho, Kwok Keung, Ed.

    2000-01-01

    This document contains the May and November 2000 issues of "New Horizons in Education," with articles in English and Chinese. The May issue includes the following articles: "A Key to Successful Environmental Education: Teacher Trainees' Attitude, Behaviour, and Knowledge" (Kevin Chung Wai Lui, Eric Po Keung Tsang, Sing Lai…

  1. New Technology and Lifelong Learning.

    ERIC Educational Resources Information Center

    Thorpe, Mary

    Key issues related to the relationship between new technology and lifelong learning in the United Kingdom and elsewhere were identified through reviews of the literature on information and communications technology (ICT) and the literature on lifelong learning. Two overarching issues related to the interplay of new technology and lifelong learning…

  2. NG9-1-1 transition issues report.

    DOT National Transportation Integrated Search

    2008-02-01

    A key outcome of the U.S. Department of Transportation (USDOT) Next Generation 9-1-1 : (NG9-1-1) Initiative is the identification of well-supported options and crucial transition issues : for migrating from todays 9-1-1 system to a NG9-1-1 system ...

  3. Does Exposure Imitate Art: Exposure Science for 21st Century Toxicity Testing

    EPA Science Inventory

    This Issues Session will continue the dialog begun at the highly successful 2008 NRC session in which the Annual Meeting participants were provided an overview of the three National Academy reports addressing key issues impacting the Society and the profession of toxicology. Thes...

  4. Rural-Urban Connections.

    ERIC Educational Resources Information Center

    Perkins, Daniel F.; LaGreca, Anthony J.; Mullis, Ronald L.

    This publication combines three papers on rural and urban youth issues. "Key Issues Facing Rural Youth" (Daniel F. Perkins) notes that rural adolescents share the same concerns and exhibit the same problem behaviors as their urban counterparts. But in addition, geographic isolation presents problems unique to rural areas. A framework is proposed…

  5. Labor force planning issues for allied health in Australia.

    PubMed

    Smith, C S; Crowley, S

    1995-01-01

    The aim of this paper is to discuss labor force planning issues for allied health professionals in Australia. Health system reform and changes in the demand for health labor, combined with key characteristics of the professions, will have a profound influence on future needs for career development of allied health professionals. Key issues include the increasing need for allied health professionals to undertake business management and public health training, the growing trend of multiskilling versus specialization, and the need for the professions to diversify their skill base to ensure a range of career options in a changing health care system. The challenge for allied health professions is to improve tools of analysis in relation to labor force planning and to systematically investigate various factors influencing labor force supply and demand, on both a short-term and long-term basis.

  6. Using Concept Mapping to Develop a Conceptual Framework for Creating Virtual Communities of Practice to Translate Cancer Research into Practice

    PubMed Central

    2014-01-01

    Introduction Translating government-funded cancer research into clinical practice can be accomplished via virtual communities of practice that include key players in the process: researchers, health care practitioners, and intermediaries. This study, conducted from November 2012 through January 2013, examined issues that key stakeholders believed should be addressed to create and sustain government-sponsored virtual communities of practice to integrate cancer control research, practice, and policy and demonstrates how concept mapping can be used to present relevant issues. Methods Key stakeholders brainstormed statements describing what is needed to create and sustain virtual communities of practice for moving cancer control research into practice. Participants rated them on importance and feasibility, selected most relevant statements, and sorted them into clusters. I used concept mapping to examine the issues identified and multidimensional scaling analyses to create a 2-dimensional conceptual map of the statement clusters. Results Participants selected 70 statements and sorted them into 9 major clusters related to creating and sustaining virtual communities of practice: 1) standardization of best practices, 2) external validity, 3) funding and resources, 4) social learning and collaboration, 5) cooperation, 6) partnerships, 7) inclusiveness, 8) social determinants and cultural competency, and 9) preparing the environment. Researchers, health care practitioners, and intermediaries were in relative agreement regarding issues of importance for creating these communities. Conclusion Virtual communities of practice can be created to address the needs of researchers, health care practitioners, and intermediaries by using input from these key stakeholders. Increasing linkages between these subgroups can improve the translation of research into practice. Similarities and differences between groups can provide valuable information to assist the government in developing virtual communities of practice. PMID:24762532

  7. Using concept mapping to develop a conceptual framework for creating virtual communities of practice to translate cancer research into practice.

    PubMed

    Vinson, Cynthia A

    2014-04-24

    Translating government-funded cancer research into clinical practice can be accomplished via virtual communities of practice that include key players in the process: researchers, health care practitioners, and intermediaries. This study, conducted from November 2012 through January 2013, examined issues that key stakeholders believed should be addressed to create and sustain government-sponsored virtual communities of practice to integrate cancer control research, practice, and policy and demonstrates how concept mapping can be used to present relevant issues. Key stakeholders brainstormed statements describing what is needed to create and sustain virtual communities of practice for moving cancer control research into practice. Participants rated them on importance and feasibility, selected most relevant statements, and sorted them into clusters. I used concept mapping to examine the issues identified and multidimensional scaling analyses to create a 2-dimensional conceptual map of the statement clusters. Participants selected 70 statements and sorted them into 9 major clusters related to creating and sustaining virtual communities of practice: 1) standardization of best practices, 2) external validity, 3) funding and resources, 4) social learning and collaboration, 5) cooperation, 6) partnerships, 7) inclusiveness, 8) social determinants and cultural competency, and 9) preparing the environment. Researchers, health care practitioners, and intermediaries were in relative agreement regarding issues of importance for creating these communities. Virtual communities of practice can be created to address the needs of researchers, health care practitioners, and intermediaries by using input from these key stakeholders. Increasing linkages between these subgroups can improve the translation of research into practice. Similarities and differences between groups can provide valuable information to assist the government in developing virtual communities of practice.

  8. BARI+: A Biometric Based Distributed Key Management Approach for Wireless Body Area Networks

    PubMed Central

    Muhammad, Khaliq-ur-Rahman Raazi Syed; Lee, Heejo; Lee, Sungyoung; Lee, Young-Koo

    2010-01-01

    Wireless body area networks (WBAN) consist of resource constrained sensing devices just like other wireless sensor networks (WSN). However, they differ from WSN in topology, scale and security requirements. Due to these differences, key management schemes designed for WSN are inefficient and unnecessarily complex when applied to WBAN. Considering the key management issue, WBAN are also different from WPAN because WBAN can use random biometric measurements as keys. We highlight the differences between WSN and WBAN and propose an efficient key management scheme, which makes use of biometrics and is specifically designed for WBAN domain. PMID:22319333

  9. BARI+: a biometric based distributed key management approach for wireless body area networks.

    PubMed

    Muhammad, Khaliq-ur-Rahman Raazi Syed; Lee, Heejo; Lee, Sungyoung; Lee, Young-Koo

    2010-01-01

    Wireless body area networks (WBAN) consist of resource constrained sensing devices just like other wireless sensor networks (WSN). However, they differ from WSN in topology, scale and security requirements. Due to these differences, key management schemes designed for WSN are inefficient and unnecessarily complex when applied to WBAN. Considering the key management issue, WBAN are also different from WPAN because WBAN can use random biometric measurements as keys. We highlight the differences between WSN and WBAN and propose an efficient key management scheme, which makes use of biometrics and is specifically designed for WBAN domain.

  10. Issues in the study of intonation in language varieties.

    PubMed

    Warren, Paul

    2005-01-01

    Some key issues in the study of intonation in language varieties are presented and discussed with reference to recent research on the intonation of New Zealand English. The particular issues that are highlighted include the determination of the intonational phonological categories of a language variety, and the attribution of varietal differences as realizational differences between varieties or as systemic differences in the categories found to be present in each variety.

  11. Employer Supported Child Care: An Idea Whose Time Has Come. A Conference on Child Care as an Employee Benefit (Costs and Benefits, Successful Programs, Company Options, Current Issues). Conference Proceedings.

    ERIC Educational Resources Information Center

    Haiman, Peter, Ed.; Sud, Gian, Ed.

    Many aspects of employer-sponsored child care programs--including key issues, costs and benefits, programmatic options, and implementation strategies--are discussed in these conference proceedings. Public policy issues, legal aspects of child care as an employee benefit, tax incentives for corporate child care, and funding sources for child care…

  12. Information Technology--Can It All Fit? Proceedings of the Current Issues Forum of the 1988 CAUSE National Conference (Nashville, Tennessee, December 2, 1988). Professional Paper Series, #2.

    ERIC Educational Resources Information Center

    CAUSE, Boulder, CO.

    A key issue facing college and university executives is the best way to organize to provide information services to faculty, staff, and students. Three experienced university executives addressed this issue at the forum on information technology described in this document. They looked at the following topics: how their own institution chose to…

  13. Guide to Rebuilding Public Sector Services in Stability Operations: A Role for the Military

    DTIC Science & Technology

    2009-10-01

    economic growth. Each topic discussion focuses on the key issues, trade-offs faced in addressing those issues in stability operations, and recommended...top-down versus bottom-up planning. As discussed above, countries have a long-term development framework that expresses broad national strategy for...SERVICES This section discusses a relatively narrow range of issues and potential actions in rebuilding government, focusing on government’s provision

  14. Education, Training and Assistance: An Issue but Not a Priority. The White House Conference on Small Business (Washington, D.C. January 13-17, 1980).

    ERIC Educational Resources Information Center

    Downing, Diane E.

    This paper describes one of the key issue areas addressed by the White House Conference on Small Business, January 13-17, 1980. This issue area of Education, Training and Assistance was one of twelve major conference themes, which included Capital Formation and Retention; Minority Business Development; Economic Policy and Government Programs;…

  15. A Round-Efficient Authenticated Key Agreement Scheme Based on Extended Chaotic Maps for Group Cloud Meeting

    PubMed Central

    Lee, Tian-Fu; Wang, Zeng-Bo

    2017-01-01

    The security is a critical issue for business purposes. For example, the cloud meeting must consider strong security to maintain the communication privacy. Considering the scenario with cloud meeting, we apply extended chaotic map to present passwordless group authentication key agreement, termed as Passwordless Group Authentication Key Agreement (PL-GAKA). PL-GAKA improves the computation efficiency for the simple group password-based authenticated key agreement (SGPAKE) proposed by Lee et al. in terms of computing the session key. Since the extended chaotic map has equivalent security level to the Diffie–Hellman key exchange scheme applied by SGPAKE, the security of PL-GAKA is not sacrificed when improving the computation efficiency. Moreover, PL-GAKA is a passwordless scheme, so the password maintenance is not necessary. Short-term authentication is considered, hence the communication security is stronger than other protocols by dynamically generating session key in each cloud meeting. In our analysis, we first prove that each meeting member can get the correct information during the meeting. We analyze common security issues for the proposed PL-GAKA in terms of session key security, mutual authentication, perfect forward security, and data integrity. Moreover, we also demonstrate that communicating in PL-GAKA is secure when suffering replay attacks, impersonation attacks, privileged insider attacks, and stolen-verifier attacks. Eventually, an overall comparison is given to show the performance between PL-GAKA, SGPAKE and related solutions. PMID:29207509

  16. Special Education Law: Illustrative Basics and Nuances of Key IDEA Components

    ERIC Educational Resources Information Center

    Zirkel, Perry A.

    2015-01-01

    Intended as professional development for both new and experienced special educators, this article provides both the basic requirements and nuanced issues for foundational, successive, and overlapping key components under the Individuals With Disabilities Education Act (IDEA): (a) child find, (b) eligibility, and (c) free appropriate public…

  17. Business Department Chairperson: An Administrator or a Teacher?

    ERIC Educational Resources Information Center

    O'Neil, Bryan L.

    The responsibilities of the business department chairperson at Castleton State College were assessed. A literature review included the area of organizational structures of academic institutions, and key faculty members and administrators at the college were interviewed to identify the key issues and problems of organizational structures and job…

  18. Qualitative Research in PBL in Health Sciences Education: A Review

    ERIC Educational Resources Information Center

    Jin, Jun; Bridges, Susan

    2016-01-01

    Context: Qualitative methodologies are relatively new in health sciences education research, especially in the area of problem-based learning (PBL). A key advantage of qualitative approaches is the ability to gain in-depth, textured insights into educational phenomena. Key methodological issues arise, however, in terms of the strategies of…

  19. The Ethics of Archival Research

    ERIC Educational Resources Information Center

    McKee, Heidi A.; Porter, James E.

    2012-01-01

    What are the key ethical issues involved in conducting archival research? Based on examination of cases and interviews with leading archival researchers in composition, this article discusses several ethical questions and offers a heuristic to guide ethical decision making. Key to this process is recognizing the person-ness of archival materials.…

  20. Keys to Transition: The California Model.

    ERIC Educational Resources Information Center

    Kearly, Patt

    This publication addresses basic issues related to the concept of transition as it is applied to students with disabilities in California. Following a pretest (and its answer key), the document uses a question and answer format to discuss common concerns about transition, normalization, the school role, the "Bridges" model developed by…

  1. Protein analysis: key to the future.

    PubMed

    Boodhun, Nawsheen

    2018-05-01

    Protein analysis is crucial to elucidating the function of proteins and understanding the impact of their presence, absence and alteration. This is key to advancing knowledge about diseases, providing the opportunity for biomarker discovery and development of therapeutics. In this issue of Tech News, Nawsheen Boodhun explores the various means of protein analysis.

  2. 75 FR 36642 - Privacy Act of 1974; System of Records

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-06-28

    ... relating to the issue, return, and accountability of keys to secure areas. Records may contain name, Social... disposing of records in the system: Storage: Paper records in file folders and electronic storage media. Retrievability: By name, Social Security Number (SSN), key number, personal identification number (PIN), Magnetic...

  3. Interface design recommendations for computerised clinical audit and feedback: Hybrid usability evidence from a research-led system.

    PubMed

    Brown, Benjamin; Balatsoukas, Panos; Williams, Richard; Sperrin, Matthew; Buchan, Iain

    2016-10-01

    Audit and Feedback (A&F) is a widely used quality improvement technique that measures clinicians' clinical performance and reports it back to them. Computerised A&F (e-A&F) system interfaces may consist of four key components: (1) Summaries of clinical performance; (2) Patient lists; (3) Patient-level data; (4) Recommended actions. There is a lack of evidence regarding how to best design e-A&F interfaces; establishing such evidence is key to maximising usability, and in turn improving patient safety. To evaluate the usability of a novel theoretically-informed and research-led e-A&F system for primary care (the Performance Improvement plaN GeneratoR: PINGR). (1) Describe PINGR's design, rationale and theoretical basis; (2) Identify usability issues with PINGR; (3) Understand how these issues may interfere with the cognitive goals of end-users; (4) Translate the issues into recommendations for the user-centred design of e-A&F systems. Eight experienced health system evaluators performed a usability inspection using an innovative hybrid approach consisting of five stages: (1) Development of representative user tasks, Goals, and Actions; (2) Combining Heuristic Evaluation and Cognitive Walkthrough methods into a single protocol to identify usability issues; (3) Consolidation of issues; (4) Severity rating of consolidated issues; (5) Analysis of issues according to usability heuristics, interface components, and Goal-Action structure. A final list of 47 issues were categorised into 8 heuristic themes. The most error-prone heuristics were 'Consistency and standards' (13 usability issues; 28% of the total) and 'Match between system and real world' (n=10, 21%). The recommended actions component of the PINGR interface had the most usability issues (n=21, 45%), followed by patient-level data (n=5, 11%), patient lists (n=4, 9%), and summaries of clinical performance (n=4, 9%). The most error-prone Actions across all user Goals were: (1) Patient selection from a list; (2) Data identification from a figure (both population-level and patient-level); (3) Disagreement with a system recommendation. By contextualising our findings within the wider literature on health information system usability, we provide recommendations for the design of e-A&F system interfaces relating to their four key components, in addition to how they may be integrated within a system. Copyright © 2016. Published by Elsevier Ireland Ltd.

  4. Making Strategic Planning Work: Experiences from a Private University. AIR 1986 Annual Forum Paper.

    ERIC Educational Resources Information Center

    Chan, Susy S.

    Issues in implementating strategic planning in higher education management are considered, along with successful strategies and problem areas in implementing an integrated planning and budgeting process at DePaul University, a comprehensive Catholic university. Key implementation issues are as follows: (1) maintaining an organizational balance…

  5. Faculty Perspectives on Programme Curricular Assessment: Individual and Institutional Characteristics That Influence Participation Engagement

    ERIC Educational Resources Information Center

    Emil, Serap; Cress, Christine

    2014-01-01

    Driven by issues of accountability, the assessment movement in higher education has gained significant momentum in recent years. However, successful implementation of assessment processes varies radically across institutions. A key issue is faculty engagement. This qualitative inquiry explored factors that impact faculty participation in a…

  6. Legal Issues for Postsecondary Education. Briefing Papers 1.

    ERIC Educational Resources Information Center

    Blumer, Dennis H., Ed.

    This publication is intended to outline basic legal issues in key areas confronting the postsecondary education community, and to provide background information of which every college administrator should be aware. Chapter 1, Some General Thoughts on Postsecondary Education and the Law, discusses the increased activity of courts in campus matters…

  7. Observing Teaching. SEDA Paper 79.

    ERIC Educational Resources Information Center

    Brown, Sally, Ed.; And Others

    This publication offers practical support to those in British higher education implementing the Observation of Teaching governmental directives. It provides discussion of key issues as well as a range of materials on how to carry out teaching observation including 23 checklists. The materials are grouped in four main areas: general issues, self…

  8. Methodological Issues in Achieving School Accountability

    ERIC Educational Resources Information Center

    Linn, Robert L.

    2008-01-01

    Test-based educational accountability is widely used in many countries, but is pervasive in the US. Key features of test-based accountability required by the US No Child Left Behind Act are discussed. Particular attention is given to methodological issues such as the distinction between status and growth approaches, the setting of performance…

  9. Minorities, Education, Empowerment.

    ERIC Educational Resources Information Center

    Hernandez, Ramona, Ed.; Torres-Saillant, Silvio, Ed.

    1992-01-01

    This special issue explores the relationship between education and empowerment and considers whether it still is valid to assume that school provides the key for people in the lower social strata in America to achieve material well being. Taken together, the essays, poetry, and studies of this issue explore the experience of social marginality in…

  10. The Importance of Knowing Ourselves.

    ERIC Educational Resources Information Center

    Farquhar, Robin H.

    This speech focuses on the protection of institutional autonomy in higher education. The speaker opens by offering some of his own basic beliefs. The balance of the paper considers three key issues central to institutional autonomy. The first issue involves specific threats to autonomy: the socio-cultural mistrust of authority and institutions,…

  11. Elementary Science Teacher Education: International Perspectives on Contemporary Issues and Practice

    ERIC Educational Resources Information Center

    Appleton, Ken, Ed.

    2006-01-01

    Reflecting recent policy and standards initiatives, emerging research agendas, and key innovations, this volume provides a contemporary overview of important developments and issues that have that have in recent years shaped elementary science education pre-service courses and professional development, and practices that are shaping future…

  12. Issues in Developing the IFSP: A Framework for Establishing Family Outcomes.

    ERIC Educational Resources Information Center

    Beckman, Paula J.; Bristol, Marie M.

    1991-01-01

    This paper identifies four key issues in the implementation of Individualized Family Service Plans (IFSPs) to provide services to young handicapped children as required by Public Law 99-457. These include sensitivity to cultural diversity, family assessment, intrusiveness, and establishing family outcomes. A typology of family outcomes which…

  13. Psychological Capital as a Predictor of Student Performance and Persistence: An Exploratory Study

    ERIC Educational Resources Information Center

    Koontz, Richard D.

    2016-01-01

    Academic performance and persistence are critically important issues for both universities and their students. Colleges and universities have invested significant resources trying to improve student outcomes. Unfortunately, in spite of this investment, improvement of student outcomes remains elusive. One key issue is that academic outcomes are…

  14. Problem-Posing Research in Mathematics Education: Looking Back, Looking Around, and Looking Ahead

    ERIC Educational Resources Information Center

    Silver, Edward A.

    2013-01-01

    In this paper, I comment on the set of papers in this special issue on mathematical problem posing. I offer some observations about the papers in relation to several key issues, and I suggest some productive directions for continued research inquiry on mathematical problem posing.

  15. Emergency Health Preparedness: Expectations for Teachers.

    ERIC Educational Resources Information Center

    Winkelman, Jack L.

    Specific issues relevant to the emergency health preparedness of schools and the key roles and expectations applicable to teachers are outlined. It is noted that, while issues of legal liability relevant to teachers are complex, teachers are expected to: (1) anticipate possible risk or harm involved in activities; (2) give adequate warning of…

  16. Dilemmas of American Policy; Crucial Issues in Contemporary Society.

    ERIC Educational Resources Information Center

    Cook, Samuel DuBois; And Others

    This volume contains four papers dealing with key social issues confronting American society; racial conflict; education (especially concerning national policies and goals); rationale for limited war for a nonmilitaristic nation; and the generation gap. Dr. Cook discusses black identity and white response and the problem of inculcating hope where…

  17. Child Maltreatment Risk Assessments: An Evaluation Guide.

    ERIC Educational Resources Information Center

    Righthand, Sue; Kerr, Bruce; Drach, Kerry

    This book is a professional practice manual designed to assist clinicians in conducting forensic risk assessment in child maltreatment cases. The authors present up-to-date research findings and provide practical, fact-based information on key issues. The book serves as a reference source on procedural issues, treatment options, and risk…

  18. Issues Involved in the Evaluation of Gifted Programmes.

    ERIC Educational Resources Information Center

    Ali, A. Sidiq

    2001-01-01

    This article discusses the purpose of gifted program evaluation and identifies some of the pertinent issues involved in evaluating gifted programs. The gifted program delivered by the Peel District Board of Education in Ontario, Canada, is used to illustrate key evaluation considerations, including gifted identification procedures and gifted…

  19. Postsecondary Distance Education in Mexico and Worldwide: Issues and Considerations

    ERIC Educational Resources Information Center

    Becerra, Bertha Leticia Gonzalez; Almendra, Manuel Pio Rosales; Flores, Jose Daniel Corona

    2012-01-01

    Postsecondary distance education has attracted increasing attention in recent years, an understandable change when one considers that innovative approaches to distance education have offered opportunities to overcome some of the key challenges in traditional "brick and mortar" education. Nonetheless, there are a plethora of issues that…

  20. Freight Mobility Issues and Recommendation for the 1997 Baltimore Regional Transportation Plan: Report of the Transportation Steering Committee's Freight Movement Task Force

    DOT National Transportation Integrated Search

    1997-09-01

    This report provides an overview of the freight movement system within the Baltimore region, with an emphasis on intermodal facilities, identifies key long-range issues, and proposes investments and actions for inclusion in the 1997 Baltimore Regiona...

Top