Sample records for refraction

  1. Postoperative refraction in the second eye having cataract surgery.

    PubMed

    Leffler, Christopher T; Wilkes, Martin; Reeves, Juliana; Mahmood, Muneera A

    2011-01-01

    Introduction. Previous cataract surgery studies assumed that first-eye predicted and observed postoperative refractions are equally important for predicting second-eye postoperative refraction. Methods. In a retrospective analysis of 173 patients having bilateral sequential phacoemulsification, multivariable linear regression was used to predict the second-eye postoperative refraction based on refractions predicted by the SRK-T formula for both eyes, the first-eye postoperative refraction, and the difference in IOL selected between eyes. Results. The first-eye observed postoperative refraction was an independent predictor of the second eye postoperative refraction (P < 0.001) and was weighted more heavily than the first-eye predicted refraction. Compared with the SRK-T formula, this model reduced the root-mean-squared (RMS) error of the predicted refraction by 11.3%. Conclusions. The first-eye postoperative refraction is an independent predictor of the second-eye postoperative refraction. The first-eye predicted refraction is less important. These findings may be due to interocular symmetry.

  2. Comparison of self-refraction using a simple device, USee, with manifest refraction in adults.

    PubMed

    Annadanam, Anvesh; Varadaraj, Varshini; Mudie, Lucy I; Liu, Alice; Plum, William G; White, J Kevin; Collins, Megan E; Friedman, David S

    2018-01-01

    The USee device is a new self-refraction tool that allows users to determine their own refractive error. We evaluated the ease of use of USee in adults, and compared the refractive error correction achieved with USee to clinical manifest refraction. Sixty adults with uncorrected visual acuity <20/30 and spherical equivalent between -6.00 and +6.00 diopters completed manifest refraction and self-refraction. Subjects had a mean (±SD) age of 53.1 (±18.6) years, and 27 (45.0%) were male. Mean (±SD) spherical equivalent measured by manifest refraction and self-refraction were -0.90 D (±2.53) and -1.22 diopters (±2.42), respectively (p = 0.001). The proportion of subjects correctable to ≥20/30 in the better eye was higher for manifest refraction (96.7%) than self-refraction (83.3%, p = 0.005). Failure to achieve visual acuity ≥20/30 with self-refraction in right eyes was associated with increasing age (per year, OR: 1.05; 95% CI: 1.00-1.10) and higher cylindrical power (per diopter, OR: 7.26; 95% CI: 1.88-28.1). Subjectively, 95% of participants thought USee was easy to use, 85% thought self-refraction correction was better than being uncorrected, 57% thought vision with self-refraction correction was similar to their current corrective lenses, and 53% rated their vision as "very good" or "excellent" with self-refraction. Self-refraction provides acceptable refractive error correction in the majority of adults. Programs targeting resource-poor settings could potentially use USee to provide easy on-site refractive error correction.

  3. Self correction of refractive error among young people in rural China: results of cross sectional investigation

    PubMed Central

    Zhang, Mingzhi; Zhang, Riping; He, Mingguang; Liang, Wanling; Li, Xiaofeng; She, Lingbing; Yang, Yunli; MacKenzie, Graeme; Silver, Joshua D; Ellwein, Leon; Moore, Bruce

    2011-01-01

    Objective To compare outcomes between adjustable spectacles and conventional methods for refraction in young people. Design Cross sectional study. Setting Rural southern China. Participants 648 young people aged 12-18 (mean 14.9 (SD 0.98)), with uncorrected visual acuity ≤6/12 in either eye. Interventions All participants underwent self refraction without cycloplegia (paralysis of near focusing ability with topical eye drops), automated refraction without cycloplegia, and subjective refraction by an ophthalmologist with cycloplegia. Main outcome measures Uncorrected and corrected vision, improvement of vision (lines on a chart), and refractive error. Results Among the participants, 59% (384) were girls, 44% (288) wore spectacles, and 61% (393/648) had 2.00 dioptres or more of myopia in the right eye. All completed self refraction. The proportion with visual acuity ≥6/7.5 in the better eye was 5.2% (95% confidence interval 3.6% to 6.9%) for uncorrected vision, 30.2% (25.7% to 34.8%) for currently worn spectacles, 96.9% (95.5% to 98.3%) for self refraction, 98.4% (97.4% to 99.5%) for automated refraction, and 99.1% (98.3% to 99.9%) for subjective refraction (P=0.033 for self refraction v automated refraction, P=0.001 for self refraction v subjective refraction). Improvements over uncorrected vision in the better eye with self refraction and subjective refraction were within one line on the eye chart in 98% of participants. In logistic regression models, failure to achieve maximum recorded visual acuity of 6/7.5 in right eyes with self refraction was associated with greater absolute value of myopia/hyperopia (P<0.001), greater astigmatism (P=0.001), and not having previously worn spectacles (P=0.002), but not age or sex. Significant inaccuracies in power (≥1.00 dioptre) were less common in right eyes with self refraction than with automated refraction (5% v 11%, P<0.001). Conclusions Though visual acuity was slightly worse with self refraction than automated or subjective refraction, acuity was excellent in nearly all these young people with inadequately corrected refractive error at baseline. Inaccurate power was less common with self refraction than automated refraction. Self refraction could decrease the requirement for scarce trained personnel, expensive devices, and cycloplegia in children’s vision programmes in rural China. PMID:21828207

  4. Postoperative Refraction in the Second Eye Having Cataract Surgery

    PubMed Central

    Leffler, Christopher T.; Wilkes, Martin; Reeves, Juliana; Mahmood, Muneera A.

    2011-01-01

    Introduction. Previous cataract surgery studies assumed that first-eye predicted and observed postoperative refractions are equally important for predicting second-eye postoperative refraction. Methods. In a retrospective analysis of 173 patients having bilateral sequential phacoemulsification, multivariable linear regression was used to predict the second-eye postoperative refraction based on refractions predicted by the SRK-T formula for both eyes, the first-eye postoperative refraction, and the difference in IOL selected between eyes. Results. The first-eye observed postoperative refraction was an independent predictor of the second eye postoperative refraction (P < 0.001) and was weighted more heavily than the first-eye predicted refraction. Compared with the SRK-T formula, this model reduced the root-mean-squared (RMS) error of the predicted refraction by 11.3%. Conclusions. The first-eye postoperative refraction is an independent predictor of the second-eye postoperative refraction. The first-eye predicted refraction is less important. These findings may be due to interocular symmetry. PMID:24533181

  5. Comparison of self-refraction using a simple device, USee, with manifest refraction in adults

    PubMed Central

    Annadanam, Anvesh; Mudie, Lucy I.; Liu, Alice; Plum, William G.; White, J. Kevin; Collins, Megan E.; Friedman, David S.

    2018-01-01

    Background The USee device is a new self-refraction tool that allows users to determine their own refractive error. We evaluated the ease of use of USee in adults, and compared the refractive error correction achieved with USee to clinical manifest refraction. Methods Sixty adults with uncorrected visual acuity <20/30 and spherical equivalent between –6.00 and +6.00 diopters completed manifest refraction and self-refraction. Results Subjects had a mean (±SD) age of 53.1 (±18.6) years, and 27 (45.0%) were male. Mean (±SD) spherical equivalent measured by manifest refraction and self-refraction were –0.90 D (±2.53) and –1.22 diopters (±2.42), respectively (p = 0.001). The proportion of subjects correctable to ≥20/30 in the better eye was higher for manifest refraction (96.7%) than self-refraction (83.3%, p = 0.005). Failure to achieve visual acuity ≥20/30 with self-refraction in right eyes was associated with increasing age (per year, OR: 1.05; 95% CI: 1.00–1.10) and higher cylindrical power (per diopter, OR: 7.26; 95% CI: 1.88–28.1). Subjectively, 95% of participants thought USee was easy to use, 85% thought self-refraction correction was better than being uncorrected, 57% thought vision with self-refraction correction was similar to their current corrective lenses, and 53% rated their vision as “very good” or “excellent” with self-refraction. Conclusion Self-refraction provides acceptable refractive error correction in the majority of adults. Programs targeting resource-poor settings could potentially use USee to provide easy on-site refractive error correction. PMID:29390026

  6. Negative refraction angular characterization in one-dimensional photonic crystals.

    PubMed

    Lugo, Jesus Eduardo; Doti, Rafael; Faubert, Jocelyn

    2011-04-06

    Photonic crystals are artificial structures that have periodic dielectric components with different refractive indices. Under certain conditions, they abnormally refract the light, a phenomenon called negative refraction. Here we experimentally characterize negative refraction in a one dimensional photonic crystal structure; near the low frequency edge of the fourth photonic bandgap. We compare the experimental results with current theory and a theory based on the group velocity developed here. We also analytically derived the negative refraction correctness condition that gives the angular region where negative refraction occurs. By using standard photonic techniques we experimentally determined the relationship between incidence and negative refraction angles and found the negative refraction range by applying the correctness condition. In order to compare both theories with experimental results an output refraction correction was utilized. The correction uses Snell's law and an effective refractive index based on two effective dielectric constants. We found good agreement between experiment and both theories in the negative refraction zone. Since both theories and the experimental observations agreed well in the negative refraction region, we can use both negative refraction theories plus the output correction to predict negative refraction angles. This can be very useful from a practical point of view for space filtering applications such as a photonic demultiplexer or for sensing applications.

  7. Negative Refraction Angular Characterization in One-Dimensional Photonic Crystals

    PubMed Central

    Lugo, Jesus Eduardo; Doti, Rafael; Faubert, Jocelyn

    2011-01-01

    Background Photonic crystals are artificial structures that have periodic dielectric components with different refractive indices. Under certain conditions, they abnormally refract the light, a phenomenon called negative refraction. Here we experimentally characterize negative refraction in a one dimensional photonic crystal structure; near the low frequency edge of the fourth photonic bandgap. We compare the experimental results with current theory and a theory based on the group velocity developed here. We also analytically derived the negative refraction correctness condition that gives the angular region where negative refraction occurs. Methodology/Principal Findings By using standard photonic techniques we experimentally determined the relationship between incidence and negative refraction angles and found the negative refraction range by applying the correctness condition. In order to compare both theories with experimental results an output refraction correction was utilized. The correction uses Snell's law and an effective refractive index based on two effective dielectric constants. We found good agreement between experiment and both theories in the negative refraction zone. Conclusions/Significance Since both theories and the experimental observations agreed well in the negative refraction region, we can use both negative refraction theories plus the output correction to predict negative refraction angles. This can be very useful from a practical point of view for space filtering applications such as a photonic demultiplexer or for sensing applications. PMID:21494332

  8. [Epidemiology of refractive errors].

    PubMed

    Wolfram, C

    2017-07-01

    Refractive errors are very common and can lead to severe pathological changes in the eye. This article analyzes the epidemiology of refractive errors in the general population in Germany and worldwide and describes common definitions for refractive errors and clinical characteristics for pathologicaal changes. Refractive errors differ between age groups due to refractive changes during the life time and also due to generation-specific factors. Current research about the etiology of refractive errors has strengthened the influence of environmental factors, which led to new strategies for the prevention of refractive pathologies.

  9. The child self-refraction study results from urban Chinese children in Guangzhou.

    PubMed

    He, Mingguang; Congdon, Nathan; MacKenzie, Graeme; Zeng, Yangfa; Silver, Joshua D; Ellwein, Leon

    2011-06-01

    To compare visual and refractive outcomes between self-refracting spectacles (Adaptive Eyecare, Ltd, Oxford, UK), noncycloplegic autorefraction, and cycloplegic subjective refraction. Cross-sectional study. Chinese school-children aged 12 to 17 years. Children with uncorrected visual acuity ≤ 6/12 in either eye underwent measurement of the logarithm of the minimum angle of resolution visual acuity, habitual correction, self-refraction without cycloplegia, autorefraction with and without cycloplegia, and subjective refraction with cycloplegia. Proportion of children achieving corrected visual acuity ≥ 6/7.5 with each modality; difference in spherical equivalent refractive error between each of the modalities and cycloplegic subjective refractive error. Among 556 eligible children of consenting parents, 554 (99.6%) completed self-refraction (mean age, 13.8 years; 59.7% girls; 54.0% currently wearing glasses). The proportion of children with visual acuity ≥ 6/7.5 in the better eye with habitual correction, self-refraction, noncycloplegic autorefraction, and cycloplegic subjective refraction were 34.8%, 92.4%, 99.5% and 99.8%, respectively (self-refraction versus cycloplegic subjective refraction, P<0.001). The mean difference between cycloplegic subjective refraction and noncycloplegic autorefraction (which was more myopic) was significant (-0.328 diopter [D]; Wilcoxon signed-rank test P<0.001), whereas cycloplegic subjective refraction and self-refraction did not differ significantly (-0.009 D; Wilcoxon signed-rank test P = 0.33). Spherical equivalent differed by ≥ 1.0 D in either direction from cycloplegic subjective refraction more frequently among right eyes for self-refraction (11.2%) than noncycloplegic autorefraction (6.0%; P = 0.002). Self-refraction power that differed by ≥ 1.0 D from cycloplegic subjective refractive error (11.2%) was significantly associated with presenting without spectacles (P = 0.011) and with greater absolute power of both spherical (P = 0.025) and cylindrical (P = 0.022) refractive error. Self-refraction seems to be less prone to accommodative inaccuracy than noncycloplegic autorefraction, another modality appropriate for use in areas where access to eye care providers is limited. Visual results seem to be comparable. Greater cylindrical power is associated with less accurate results; the adjustable glasses used in this study cannot correct astigmatism. Further studies of the practical applications of this modality are warranted. Proprietary or commercial disclosure may be found after the references. Copyright © 2011 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  10. Reproducibility of manifest refraction between surgeons and optometrists in a clinical refractive surgery practice.

    PubMed

    Reinstein, Dan Z; Yap, Timothy E; Carp, Glenn I; Archer, Timothy J; Gobbe, Marine

    2014-03-01

    To measure and compare the interobserver reproducibility of manifest refraction according to a standardized protocol for normal preoperative patients in a refractive surgery practice. Private clinic, London, United Kingdom. Retrospective case series. This retrospective study comprised patients attending 2 preoperative refractions before laser vision correction. The first manifest refraction was performed by 1 of 7 optometrists and the second manifest refraction by 1 of 2 surgeons, all trained using a standard manifest refraction protocol. Spherocylindrical data were converted into power vectors for analysis. The dioptric power differences between observers were calculated and analyzed. One thousand nine hundred twenty-two consecutive eyes were stratified into a myopia group and a hyperopia group and then further stratified by each surgeon-optometrist combination. The mean surgeon-optometrist dioptric power difference was 0.21 diopter (D) (range 0.15 to 0.32 D). The mean difference in spherical equivalent refraction was 0.03 D, with 95% of all refractions within ±0.44 D for all optometrist-surgeon combinations. The severity of myopic or hyperopic ametropia did not affect the interobserver reproducibility of the manifest refraction. There was close agreement in refraction between surgeons and optometrists using a standard manifest refraction protocol of less than 0.25 D. This degree of interobserver repeatability is similar to that in intraobserver repeatability studies published to date and may represent the value of training and the use of a standard manifest refraction protocol between refraction observers in a refractive surgery practice involving co-management between surgeons and optometrists. Copyright © 2014 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  11. Holographic Refraction and the Measurement of Spherical Ametropia.

    PubMed

    Nguyen, Nicholas Hoai Nam

    2016-10-01

    To evaluate the performance of a holographic logMAR chart for the subjective spherical refraction of the human eye. Bland-Altman analysis was used to assess the level of agreement between subjective spherical refraction using the holographic logMAR chart and conventional autorefraction and subjective spherical refraction. The 95% limits of agreement (LoA) were calculated between holographic refraction and the two standard methods (subjective and autorefraction). Holographic refraction has a lower mean spherical refraction when compared to conventional refraction (LoA 0.11 ± 0.65 D) and when compared to autorefraction (LoA 0.36 ± 0.77 D). After correcting for systemic bias, this is comparable between autorefraction and conventional subjective refraction (LoA 0.45 ± 0.79 D). After correcting for differences in vergence distance and chromatic aberration between holographic and conventional refraction, approximately 65% (group 1) of measurements between holography and conventional subjective refraction were similar (MD = 0.13 D, SD = 0.00 D). The remaining 35% (group 2) had a mean difference of 0.45 D (SD = 0.12 D) between the two subjective methods. Descriptive statistics showed group 2's mean age (21 years, SD = 13 years) was considerably lower than group 1's mean age (41 years, SD = 17), suggesting accommodation may have a role in the greater mean difference of group 2. Overall, holographic refraction has good agreement with conventional refraction and is a viable alternative for spherical subjective refraction. A larger bias between holographic and conventional refraction was found in younger subjects than older subjects, suggesting an association between accommodation and myopic over-correction during holographic refraction.

  12. Wave refraction in negative-index media: always positive and very inhomogeneous.

    PubMed

    Valanju, P M; Walser, R M; Valanju, A P

    2002-05-06

    We present the first treatment of the refraction of physical electromagnetic waves in newly developed negative index media (NIM), also known as left-handed media (LHM). The NIM dispersion relation implies that group fronts refract positively even when phase fronts refract negatively. This difference results in rapidly dispersing, very inhomogeneous waves. In fact, causality and finite signal speed always prevent negative wave signal (not phase) refraction. Earlier interpretations of phase refraction as "negative light refraction" and "light focusing by plane slabs" are therefore incorrect, and published NIM experiments can be explained without invoking negative signal refraction.

  13. Heritability of peripheral refraction in Chinese children and adolescents: the Guangzhou Twin Eye study.

    PubMed

    Ding, Xiaohu; Lin, Zhi; Huang, Qunxiao; Zheng, Yingfeng; Congdon, Nathan; He, Mingguang

    2012-01-10

    To estimate the heritability of peripheral refraction in Chinese children and adolescents. The authors examined 72 monozygotic (MZ) twins and 48 dizygotic (DZ) twins aged 8 to 20 years from a population-based twin registry. Temporal and nasal peripheral refraction, each 40° from the visual axis, and axial refraction were measured using an autorefractor. Relative peripheral refractive error (RPRE) was defined as the peripheral refraction minus the axial refraction. Heritability was assessed by structural equation modeling after adjustment for age and sex. The mean and SD of temporal refraction (T(40)), nasal refraction (N(40)), RPRE-T(40), RPRE-N(40), and T(40)-N(40) asymmetry were -0.27 ± 2.0 D, 0.36 ± 2.19 D, 1.18 ± 1.39 D, 1.80 ± 1.69 D, and -0.62 ± 1.58 D, respectively. The intraclass correlations for T(40) refraction, N(40) refraction, RPRE-T(40), RPRE-N(40), and T(40)-N(40) asymmetry were 0.87, 0.83, 0.65, 0.74, and 0.58 for MZ pairs and 0.49, 0.42, 0.30, 0.41, and 0.32 for DZ pairs, respectively. A model with additive genetic and unique environmental effects was the most parsimonious, with heritability values estimated as 0.84, 0.76, 0.63, 0.70, and 0.55, respectively, for the peripheral refractive parameters. Additive genetic effects appear to explain most of the variance in peripheral refraction and relative peripheral refraction when adjusting for the effects of axial refraction.

  14. Relative peripheral hyperopic defocus alters central refractive development in infant monkeys

    PubMed Central

    Smith, Earl L.; Hung, Li-Fang; Huang, Juan

    2009-01-01

    Understanding the role of peripheral defocus on central refractive development is critical because refractive errors can vary significantly with eccentricity and peripheral refractions have been implicated in the genesis of central refractive errors in humans. Two rearing strategies were used to determine whether peripheral hyperopia alters central refractive development in rhesus monkeys. In intact eyes, lens-induced relative peripheral hyperopia produced central axial myopia. Moreover, eliminating the fovea by laser photoablation did not prevent compensating myopic changes in response to optically imposed hyperopia. These results show that peripheral refractive errors can have a substantial impact on central refractive development in primates. PMID:19632261

  15. Is an objective refraction optimised using the visual Strehl ratio better than a subjective refraction?

    PubMed Central

    Hastings, Gareth D.; Marsack, Jason D.; Nguyen, Lan Chi; Cheng, Han; Applegate, Raymond A.

    2017-01-01

    Purpose To prospectively examine whether using the visual image quality metric, visual Strehl (VSX), to optimise objective refraction from wavefront error measurements can provide equivalent or better visual performance than subjective refraction and which refraction is preferred in free viewing. Methods Subjective refractions and wavefront aberrations were measured on 40 visually-normal eyes of 20 subjects, through natural and dilated pupils. For each eye a sphere, cylinder, and axis prescription was also objectively determined that optimised visual image quality (VSX) for the measured wavefront error. High contrast (HC) and low contrast (LC) logMAR visual acuity (VA) and short-term monocular distance vision preference were recorded and compared between the VSX-objective and subjective prescriptions both undilated and dilated. Results For 36 myopic eyes, clinically equivalent (and not statistically different) HC VA was provided with both the objective and subjective refractions (undilated mean ±SD was −0.06 ±0.04 with both refractions; dilated was −0.05 ±0.04 with the objective, and −0.05 ±0.05 with the subjective refraction). LC logMAR VA provided by the objective refraction was also clinically equivalent and not statistically different to that provided by the subjective refraction through both natural and dilated pupils for myopic eyes. In free viewing the objective prescription was preferred over the subjective by 72% of myopic eyes when not dilated. For four habitually undercorrected high hyperopic eyes, the VSX-objective refraction was more positive in spherical power and VA poorer than with the subjective refraction. Conclusions A method of simultaneously optimising sphere, cylinder, and axis from wavefront error measurements, using the visual image quality metric VSX, is described. In myopic subjects, visual performance, as measured by HC and LC VA, with this VSX-objective refraction was found equivalent to that provided by subjective refraction, and was typically preferred over subjective refraction. Subjective refraction was preferred by habitually undercorrected hyperopic eyes. PMID:28370389

  16. Crystalline lens power and refractive error.

    PubMed

    Iribarren, Rafael; Morgan, Ian G; Nangia, Vinay; Jonas, Jost B

    2012-02-01

    To study the relationships between the refractive power of the crystalline lens, overall refractive error of the eye, and degree of nuclear cataract. All phakic participants of the population-based Central India Eye and Medical Study with an age of 50+ years were included. Calculation of the refractive lens power was based on distance noncycloplegic refractive error, corneal refractive power, anterior chamber depth, lens thickness, and axial length according to Bennett's formula. The study included 1885 subjects. Mean refractive lens power was 25.5 ± 3.0 D (range, 13.9-36.6). After adjustment for age and sex, the standardized correlation coefficients (β) of the association with the ocular refractive error were highest for crystalline lens power (β = -0.41; P < 0.001) and nuclear lens opacity grade (β = -0.42; P < 0.001), followed by axial length (β = -0.35; P < 0.001). They were lowest for corneal refractive power (β = -0.08; P = 0.001) and anterior chamber depth (β = -0.05; P = 0.04). In multivariate analysis, refractive error was significantly (P < 0.001) associated with shorter axial length (β = -1.26), lower refractive lens power (β = -0.95), lower corneal refractive power (β = -0.76), higher lens thickness (β = 0.30), deeper anterior chamber (β = 0.28), and less marked nuclear lens opacity (β = -0.05). Lens thickness was significantly lower in eyes with greater nuclear opacity. Variations in refractive error in adults aged 50+ years were mostly influenced by variations in axial length and in crystalline lens refractive power, followed by variations in corneal refractive power, and, to a minor degree, by variations in lens thickness and anterior chamber depth.

  17. Effect of Nd:YAG laser capsulotomy on refraction in multifocal apodized diffractive pseudophakia.

    PubMed

    Vrijman, Violette; van der Linden, Jan Willem; Nieuwendaal, Carla P; van der Meulen, Ivanka J E; Mourits, Maarten P; Lapid-Gortzak, Ruth

    2012-08-01

    To evaluate the effect on refraction of neodymium:YAG (Nd:YAG) laser posterior capsulotomy for posterior capsule opacification (PCO), and to evaluate the correlation between automated and subjective refraction in multifocal apodized diffractive pseudophakia. A retrospective study of 75 pseudophakic eyes (50 patients) with multifocal apodized diffractive pseudophakia, treated for PCO with Nd:YAG laser posterior capsulotomy, was performed. Pre- and postintervention values of refractive and visual parameters were compared. The outcomes of autorefraction and subjective refraction were also compared. Uncorrected and corrected distance visual acuity improved significantly after Nd:YAG capsulotomy (P<.001). No significant changes were noted in defocus equivalent, astigmatic power vectors J(0) and J(45), and overall blurring strength in subjective refraction and autorefraction. Spherical equivalent changed significantly in autorefraction (P=.008), but not in subjective refraction. Autorefraction and subjective refraction were highly correlated in spherical equivalent, defocus equivalent, and blurring strength (r(2)>0.59). In approximately 7% of eyes, a change of more than 0.50 diopters in spherical equivalent in subjective refraction occurred. In most cases, Nd:YAG laser capsulotomy in patients with multifocal pseudophakia did not result in a change in refraction. However, 7% of eyes experienced a significant change in subjective refraction. Autorefraction correlated well with subjective refraction in apodized diffractive multifocal IOLs. Copyright 2012, SLACK Incorporated.

  18. Toward eliminating blindness due to uncorrected refractive errors: assessment of refractive services in the northern and central regions of Ghana.

    PubMed

    Ntodie, Michael; Danquah, Lisa; Kandel, Himal; Abokyi, Samuel

    2014-11-01

    This study sought to document current refractive services in the northern and central regions of Ghana as a first step toward evidence-based planning of refractive services. A descriptive cross-sectional survey was carried out in health facilities in the northern and central regions of Ghana, which provided eye-care services. A semi-structured questionnaire was administered to gather information on each facility type, human resources providing refractive services, assessment of refraction and spectacle dispensing output and provider barriers to the services. Current outputs of refraction in the northern and central regions were 0.5 and 1.2 per cent of the estimated refractive needs, respectively. Spectacle dispensing services were below the outputs of refraction. Lack of equipment (36.8 per cent) and cost of providing spectacles frames (31.6 per cent), were identified as the main barriers to providing refractive services. The provision of refractive services in the study regions was inadequate. Lack of infrastructure and inadequate human resource were the major reasons for the limited service provision. This should be considered for planning refractive services in the study regions and Ghana as a whole. © 2014 The Authors. Clinical and Experimental Optometry © 2014 Optometrists Association Australia.

  19. Refractive errors in presbyopic patients in Kano, Nigeria.

    PubMed

    Lawan, Abdu; Okpo, Eme; Philips, Ebisike

    2014-01-01

    The study is a retrospective review of the pattern of refractive errors in presbyopic patients seen in the eye clinic from January to December, 2009. The clinic refraction register was used to retrieve the case folders of all patients refracted during the review period. Information extracted includes patient's age, sex, and types of refractive error. Unaided and pin hole visual acuity was done with Snellen's or "E" Charts and near vision with Jaeger's chart in English or Hausa. All patients had basic eye examination and streak retinoscopy at two third meter working distance. The final subjective refractive correction given to the patients was used to categorize the type of refractive error. There were 5893 patients, 1584 had refractive error and 644 were presbyopic. There were 289 males and 355 females (M:F= 1:1.2). Presbyopia accounted for 10.9% of clinic attendance and 40% of patients with refractive error. Presbyopia was seen in 17%, the remaining 83% required distance correction; astigmatism was seen in 41%, hypermetropia 29%, myopia 9% and aphakia 4%. Refractive error was commoner in females than males and the relationship was statistically significant (P-value = 0.017; P < 0.05 considered significant). Presbyopia is common and most of the patients had other refractive errors. Full refraction is advised for all patients.

  20. Ketamine-xylazine anesthesia causes hyperopic refractive shift in mice

    PubMed Central

    Tkatchenko, Tatiana V.; Tkatchenko, Andrei V.

    2010-01-01

    Mice have increasingly been used as a model for studies of myopia. The key to successful use of mice for myopia research is the ability to obtain accurate measurements of refractive status of their eyes. In order to obtain accurate measurements of refractive errors in mice, the refraction needs to be performed along the optical axis of the eye. This represents a particular challenge, because mice are very difficult to immobilize. Recently, ketamine-xylazine anesthesia has been used to immobilize mice before measuring refractive errors, in combination with tropicamide ophthalmic solution to induce mydriasis. Although these drugs have increasingly been used while refracting mice, their effects on the refractive state of the mouse eye have not yet been investigated. Therefore, we have analyzed the effects of tropicamide eye drops and ketamine-xylazine anesthesia on refraction in P40 C57BL/6J mice. We have also explored two alternative methods to immobilize mice, i.e. the use of a restraining platform and pentobarbital anesthesia. We found that tropicamide caused a very small, but statistically significant, hyperopic shift in refraction. Pentobarbital did not have any substantial effect on refractive status, whereas ketamine-xylazine caused a large and highly significant hyperopic shift in refraction. We also found that the use of a restraining platform represents good alternative for immobilization of mice prior to refraction. Thus, our data suggest that ketamine-xylazine anesthesia should be avoided in studies of refractive development in mice and underscore the importance of providing appropriate experimental conditions when measuring refractive errors in mice. PMID:20813132

  1. Refractive index of liquid mixtures: theory and experiment.

    PubMed

    Reis, João Carlos R; Lampreia, Isabel M S; Santos, Angela F S; Moita, Maria Luísa C J; Douhéret, Gérard

    2010-12-03

    An innovative approach is presented to interpret the refractive index of binary liquid mixtures. The concept of refractive index "before mixing" is introduced and shown to be given by the volume-fraction mixing rule of the pure-component refractive indices (Arago-Biot formula). The refractive index of thermodynamically ideal liquid mixtures is demonstrated to be given by the volume-fraction mixing rule of the pure-component squared refractive indices (Newton formula). This theoretical formulation entails a positive change of refractive index upon ideal mixing, which is interpreted in terms of dissimilar London dispersion forces centred in the dissimilar molecules making up the mixture. For real liquid mixtures, the refractive index of mixing and the excess refractive index are introduced in a thermodynamic manner. Examples of mixtures are cited for which excess refractive indices and excess molar volumes show all of the four possible sign combinations, a fact that jeopardises the finding of a general equation linking these two excess properties. Refractive indices of 69 mixtures of water with the amphiphile (R,S)-1-propoxypropan-2-ol are reported at five temperatures in the range 283-303 K. The ideal and real refractive properties of this binary system are discussed. Pear-shaped plots of excess refractive indices against excess molar volumes show that extreme positive values of excess refractive index occur at a substantially lower mole fraction of the amphiphile than extreme negative values of excess molar volume. Analysis of these plots provides insights into the mixing schemes that occur in different composition segments. A nearly linear variation is found when Balankina's ratios between excess and ideal values of refractive indices are plotted against ratios between excess and ideal values of molar volumes. It is concluded that, when coupled with volumetric properties, the new thermodynamic functions defined for the analysis of refractive indices of liquid mixtures give important complementary information on the mixing process over the whole composition range.

  2. Calculations of atmospheric refraction for spacecraft remote-sensing applications

    NASA Technical Reports Server (NTRS)

    Chu, W. P.

    1983-01-01

    Analytical solutions to the refraction integrals appropriate for ray trajectories along slant paths through the atmosphere are derived in this paper. This type of geometry is commonly encountered in remote-sensing applications utilizing an occultation technique. The solutions are obtained by evaluating higher-order terms from expansion of the refraction integral and are dependent on the vertical temperature distributions. Refraction parameters such as total refraction angles, air masses, and path lengths can be accurately computed. It is also shown that the method can be used for computing refraction parameters in astronomical refraction geometry for large zenith angles.

  3. [Character of refractive errors in population study performed by the Area Military Medical Commission in Lodz].

    PubMed

    Nowak, Michał S; Goś, Roman; Smigielski, Janusz

    2008-01-01

    To determine the prevalence of refractive errors in population. A retrospective review of medical examinations for entry to the military service from The Area Military Medical Commission in Lodz. Ophthalmic examinations were performed. We used statistic analysis to review the results. Statistic analysis revealed that refractive errors occurred in 21.68% of the population. The most commen refractive error was myopia. 1) The most commen ocular diseases are refractive errors, especially myopia (21.68% in total). 2) Refractive surgery and contact lenses should be allowed as the possible correction of refractive errors for military service.

  4. Design of Amphoteric Refraction Models Using WAVICA and RAYICA

    NASA Technical Reports Server (NTRS)

    Su, Richard

    2004-01-01

    The phenomenon of refraction of light is due to refractive index mismatches in two different media. However, to achieve this effect, a finite reflection loss is inevitable. A recent finding presented a unique type of interface, ferroelastic materials, that enables refraction without any reflection for either an electron or a light beam. This property is called total refraction. The same type of interface that yields total refraction can also yield amphoteric refraction, where the index of refraction can be either positive or negative depending on the incident angle. This interface could potentially be used to steer light without reflections which could have major applications in high power optics. My goal this summer is to first familiarize myself with the Mathematica software, especially the Wavica and Rayica packages. I will then model the amphoteric refraction by either modifying the Wavica and Rayica packages or using the built-in functions in these packages.

  5. Transient establishment of the wavefronts for negative, zero, and positive refraction.

    PubMed

    Zhao, Wenjuan; Wu, Qiang; Wang, Ride; Gao, Jianshun; Lu, Yao; Zhang, Qi; Qi, Jiwei; Zhang, Chunling; Pan, Chongpei; Rupp, Romano; Xu, Jingjun

    2018-01-22

    We quantitatively demonstrate transient establishment of wavefronts for negative, zero, and positive refraction through a wedge-shaped metamaterial consisting of periodically arranged split-ring resonators and metallic wires. The wavefronts for the three types of refractions propagate through the second interface of the wedge along positive refraction angles at first, then reorganize, and finally propagate along the effective refraction angles after a period of establishment time respectively. The establishment time of the wavefronts prevents violating causality or superluminal propagation for negative and zero refraction. The establishment time for negative or zero refraction is longer than that for positive refraction. For all three refraction processes, transient establishment processes precede the establishment of steady propagation. Moreover, some detailed characters are proven in our research, including infinite wavelength, uniform phase inside the zero-index material, and the phase velocity being antiparallel to the group velocity in the negative-index material.

  6. Gradients of refractive index in the crystalline lens and transient changes in refraction among patients with diabetes.

    PubMed

    Charman, W Neil; Adnan; Atchison, David A

    2012-12-01

    Transient hyperopic refractive shifts occur on a timescale of weeks in some patients after initiation of therapy for hyperglycemia, and are usually followed by recovery to the original refraction. Possible lenticular origin of these changes is considered in terms of a paraxial gradient index model. Assuming that the lens thickness and curvatures remain unchanged, as observed in practice, it appears possible to account for initial hyperopic refractive shifts of up to a few diopters by reduction in refractive index near the lens center and alteration in the rate of change between center and surface, so that most of the index change occurs closer to the lens surface. Restoration of the original refraction depends on further change in the refractive index distribution with more gradual changes in refractive index from the lens center to its surface. Modeling limitations are discussed.

  7. Gradients of refractive index in the crystalline lens and transient changes in refraction among patients with diabetes

    PubMed Central

    Charman, W. Neil; Adnan; Atchison, David A.

    2012-01-01

    Transient hyperopic refractive shifts occur on a timescale of weeks in some patients after initiation of therapy for hyperglycemia, and are usually followed by recovery to the original refraction. Possible lenticular origin of these changes is considered in terms of a paraxial gradient index model. Assuming that the lens thickness and curvatures remain unchanged, as observed in practice, it appears possible to account for initial hyperopic refractive shifts of up to a few diopters by reduction in refractive index near the lens center and alteration in the rate of change between center and surface, so that most of the index change occurs closer to the lens surface. Restoration of the original refraction depends on further change in the refractive index distribution with more gradual changes in refractive index from the lens center to its surface. Modeling limitations are discussed. PMID:23243557

  8. Predicted and measured boundary layer refraction for advanced turboprop propeller noise

    NASA Technical Reports Server (NTRS)

    Dittmar, James H.; Krejsa, Eugene A.

    1990-01-01

    Currently, boundary layer refraction presents a limitation to the measurement of forward arc propeller noise measured on an acoustic plate in the NASA Lewis 8- by 6-Foot Supersonic Wind Tunnel. The use of a validated boundary layer refraction model to adjust the data could remove this limitation. An existing boundary layer refraction model is used to predict the refraction for cases where boundary layer refraction was measured. In general, the model exhibits the same qualitative behavior as the measured refraction. However, the prediction method does not show quantitative agreement with the data. In general, it overpredicts the amount of refraction for the far forward angles at axial Mach number of 0.85 and 0.80 and underpredicts the refraction at axial Mach numbers of 0.75 and 0.70. A more complete propeller source description is suggested as a way to improve the prediction method.

  9. Emmetropisation and the aetiology of refractive errors

    PubMed Central

    Flitcroft, D I

    2014-01-01

    The distribution of human refractive errors displays features that are not commonly seen in other biological variables. Compared with the more typical Gaussian distribution, adult refraction within a population typically has a negative skew and increased kurtosis (ie is leptokurtotic). This distribution arises from two apparently conflicting tendencies, first, the existence of a mechanism to control eye growth during infancy so as to bring refraction towards emmetropia/low hyperopia (ie emmetropisation) and second, the tendency of many human populations to develop myopia during later childhood and into adulthood. The distribution of refraction therefore changes significantly with age. Analysis of the processes involved in shaping refractive development allows for the creation of a life course model of refractive development. Monte Carlo simulations based on such a model can recreate the variation of refractive distributions seen from birth to adulthood and the impact of increasing myopia prevalence on refractive error distributions in Asia. PMID:24406411

  10. Postoperative Refractive Errors Following Pediatric Cataract Extraction with Intraocular Lens Implantation.

    PubMed

    Indaram, Maanasa; VanderVeen, Deborah K

    2018-01-01

    Advances in surgical techniques allow implantation of intraocular lenses (IOL) with cataract extraction, even in young children. However, there are several challenges unique to the pediatric population that result in greater degrees of postoperative refractive error compared to adults. Literature review of the techniques and outcomes of pediatric cataract surgery with IOL implantation. Pediatric cataract surgery is associated with several sources of postoperative refractive error. These include planned refractive error based on age or fellow eye status, loss of accommodation, and unexpected refractive errors due to inaccuracies in biometry technique, use of IOL power formulas based on adult normative values, and late refractive changes due to unpredictable eye growth. Several factors can preclude the achievement of optimal refractive status following pediatric cataract extraction with IOL implantation. There is a need for new technology to reduce postoperative refractive surprises and address refractive adjustment in a growing eye.

  11. [Peripheral refraction: cause or effect of refraction development?

    PubMed

    Tarutta, E P; Iomdina, E N; Kvaratskheliya, N G; Milash, S V; Kruzhkova, G V

    to study peripheral refraction and the shape of the eyeball in children with different clinical refraction. Using an original method, peripheral refraction was measured at 10-12 degrees temporally and nasally from the fovea in 56 right eyes with different clinical, or axial, refraction of 20 boys and 36 girls aged 7 to 16 years (11.9±1.17 years on average). The shape of the eyeball was judged of by the ratio of its anterior-posterior axial length (AL) to horizontal diameter (HD). The incidence and value of peripheral myopic defocus in children appeared to decrease with clinical refraction increasing from high hyperopia to high myopia. This was the first time, mixed peripheral refraction was found in children, occurring more frequently in higher myopia. This mixed peripheral defocus, shown to be a transitional stage between relative peripheral myopia and relative hyperopia, indicates non-uniform stretching of posterior pole tissues in the course of refraction development and myopia progression. As ocular refraction increases from high hyperopia to high myopia, the growth of AL outpaces that of HD. Obviously, natural peripheral defocus results from changes in size and shape of the eyeball in the course of refraction development.

  12. Refractive errors in Aminu Kano Teaching Hospital, Kano Nigeria.

    PubMed

    Lawan, Abdu; Eme, Okpo

    2011-12-01

    The aim of the study is to retrospectively determine the pattern of refractive errors seen in the eye clinic of Aminu Kano Teaching Hospital, Kano-Nigeria from January to December, 2008. The clinic refraction register was used to retrieve the case folders of all patients refracted during the review period. Information extracted includes patient's age, sex, and types of refractive error. All patients had basic eye examination (to rule out other causes of subnormal vision) including intra ocular pressure measurement and streak retinoscopy at two third meter working distance. The final subjective refraction correction given to the patients was used to categorise the type of refractive error. Refractive errors was observed in 1584 patients and accounted for 26.9% of clinic attendance. There were more females than males (M: F=1.0: 1.2). The common types of refractive errors are presbyopia in 644 patients (40%), various types of astigmatism in 527 patients (33%), myopia in 216 patients (14%), hypermetropia in 171 patients (11%) and aphakia in 26 patients (2%). Refractive errors are common causes of presentation in the eye clinic. Identification and correction of refractive errors should be an integral part of eye care delivery.

  13. The refractive index of human hemoglobin in the visible range.

    PubMed

    Zhernovaya, O; Sydoruk, O; Tuchin, V; Douplik, A

    2011-07-07

    Because the refractive index of hemoglobin in the visible range is sensitive to the hemoglobin concentration, optical investigations of hemoglobin are important for medical diagnostics and treatment. Direct measurements of the refractive index are, however, challenging; few such measurements have previously been reported, especially in a wide wavelength range. We directly measured the refractive index of human deoxygenated and oxygenated hemoglobin for nine wavelengths between 400 and 700 nm for the hemoglobin concentrations up to 140 g l(-1). This paper analyzes the results and suggests a set of model functions to calculate the refractive index depending on the concentration. At all wavelengths, the measured values of the refractive index depended on the concentration linearly. Analyzing the slope of the lines, we determined the specific refraction increments, derived a set of model functions for the refractive index depending on the concentration, and compared our results with those available in the literature. Based on the model functions, we further calculated the refractive index at the physiological concentration within the erythrocytes of 320 g l(-1). The results can be used to calculate the refractive index in the visible range for arbitrary concentrations provided that the refractive indices depend on the concentration linearly.

  14. Peripheral refraction in normal infant rhesus monkeys

    PubMed Central

    Hung, Li-Fang; Ramamirtham, Ramkumar; Huang, Juan; Qiao-Grider, Ying; Smith, Earl L.

    2008-01-01

    Purpose To characterize peripheral refractions in infant monkeys. Methods Cross-sectional data for horizontal refractions were obtained from 58 normal rhesus monkeys at 3 weeks of age. Longitudinal data were obtained for both the vertical and horizontal meridians from 17 monkeys. Refractive errors were measured by retinoscopy along the pupillary axis and at eccentricities of 15, 30, and 45 degrees. Axial dimensions and corneal power were measured by ultrasonography and keratometry, respectively. Results In infant monkeys, the degree of radial astigmatism increased symmetrically with eccentricity in all meridians. There were, however, initial nasal-temporal and superior-inferior asymmetries in the spherical-equivalent refractive errors. Specifically, the refractions in the temporal and superior fields were similar to the central ametropia, but the refractions in the nasal and inferior fields were more myopic than the central ametropia and the relative nasal field myopia increased with the degree of central hyperopia. With age, the degree of radial astigmatism decreased in all meridians and the refractions became more symmetrical along both the horizontal and vertical meridians; small degrees of relative myopia were evident in all fields. Conclusions As in adult humans, refractive error varied as a function of eccentricity in infant monkeys and the pattern of peripheral refraction varied with the central refractive error. With age, emmetropization occurred for both central and peripheral refractive errors resulting in similar refractions across the central 45 degrees of the visual field, which may reflect the actions of vision-dependent, growth-control mechanisms operating over a wide area of the posterior globe. PMID:18487366

  15. Is an objective refraction optimised using the visual Strehl ratio better than a subjective refraction?

    PubMed

    Hastings, Gareth D; Marsack, Jason D; Nguyen, Lan Chi; Cheng, Han; Applegate, Raymond A

    2017-05-01

    To prospectively examine whether using the visual image quality metric, visual Strehl (VSX), to optimise objective refraction from wavefront error measurements can provide equivalent or better visual performance than subjective refraction and which refraction is preferred in free viewing. Subjective refractions and wavefront aberrations were measured on 40 visually-normal eyes of 20 subjects, through natural and dilated pupils. For each eye a sphere, cylinder, and axis prescription was also objectively determined that optimised visual image quality (VSX) for the measured wavefront error. High contrast (HC) and low contrast (LC) logMAR visual acuity (VA) and short-term monocular distance vision preference were recorded and compared between the VSX-objective and subjective prescriptions both undilated and dilated. For 36 myopic eyes, clinically equivalent (and not statistically different) HC VA was provided with both the objective and subjective refractions (undilated mean ± S.D. was -0.06 ± 0.04 with both refractions; dilated was -0.05 ± 0.04 with the objective, and -0.05 ± 0.05 with the subjective refraction). LC logMAR VA provided by the objective refraction was also clinically equivalent and not statistically different to that provided by the subjective refraction through both natural and dilated pupils for myopic eyes. In free viewing the objective prescription was preferred over the subjective by 72% of myopic eyes when not dilated. For four habitually undercorrected high hyperopic eyes, the VSX-objective refraction was more positive in spherical power and VA poorer than with the subjective refraction. A method of simultaneously optimising sphere, cylinder, and axis from wavefront error measurements, using the visual image quality metric VSX, is described. In myopic subjects, visual performance, as measured by HC and LC VA, with this VSX-objective refraction was found equivalent to that provided by subjective refraction, and was typically preferred over subjective refraction. Subjective refraction was preferred by habitually undercorrected hyperopic eyes. © 2017 The Authors Ophthalmic & Physiological Optics © 2017 The College of Optometrists.

  16. Comparison of objective refraction in darkness to cycloplegic refraction: a pilot study.

    PubMed

    Vasudevan, Balamurali; Ciuffreda, Kenneth J; Meehan, Kelly; Grk, Dejana; Cox, Misty

    2016-03-01

    The aim was to assess non-cycloplegic objective refraction in darkness using an open-field auto-refractor, and furthermore to compare it with distance cycloplegic subjective refraction and distance cycloplegic retinoscopy in the light, in children and young adults. Twenty-three, visually-normal, young-adults (46 eyes) ages 23 to 31 years, and five children (10 eyes) ages five to 12 years, participated in the study. The spherical component of their refraction ranged from -2.25 D to +3.75 D with a mean of +1.80 D, and a mean cylinder of -0.70 D. Three techniques were used to assess refractive error. An objective measure of the non-cycloplegic refractive state was obtained using an open-field autorefractor (WAM-5500) after five minutes in the dark to allow for dissipation of accommodative transients and relaxation of accommodation. In addition, both distance retinoscopy and subjective distance refraction were performed following cycloplegia (Cyclopentolate, 1%) using conventional clinical procedures. All measurements were obtained on the same day within a single session. The spherical component of the refraction was compared among the three techniques in both the children and adults. There was no significant difference in spherical refraction among the three techniques: non-cycloplegic objective refraction in the dark, distance cycloplegic retinoscopy and distance cycloplegic subjective refraction, in either the adults [F(2, 137) = 0.79, p = 0.45] or the children [F(2, 27) = 0.47, p = 0.62]. Mean difference in the spherical component between refraction in the dark and the cycloplegic distance retinoscopy was -0.34 D (r = 0.89) in the adults and +0.14 D (r = 0.96) in the children. The mean difference in spherical component between refraction in the dark and the cycloplegic distance subjective refraction was -0.25 D (r = 0.92) in the adults and -0.05 D (r = 0.95) in the children. Comparison of the spherical refractive component between the three techniques was not significantly different and furthermore, they were highly correlated in both the children and adults in this pilot study. Non-cycloplegic refraction in the dark may provide a reliable adjunct or alternative to conventional cycloplegic refraction in both children and young adults. © 2016 Optometry Australia.

  17. Influence of spherical aberration, stimulus spatial frequency, and pupil apodisation on subjective refractions

    PubMed Central

    Bradley, Arthur; Xu, Renfeng; Thibos, Larry; Marin, Gildas; Hernandez, Martha

    2014-01-01

    Purpose To test competing hypotheses (Stiles Crawford pupil apodising or superior imaging of high spatial frequencies by the central pupil) for the pupil size independence of subjective refractions in the presence of primary spherical aberration. Methods Subjective refractions were obtained with a variety of test stimuli (high contrast letters, urban cityscape, high and low spatial frequency gratings) while modulating pupil diameter, levels of primary spherical aberration and pupil apodisation. Subjective refractions were also obtained with low-pass and high-pass stimuli and using “darker” and “sharper” subjective criteria. Results Subjective refractions for stimuli containing high spatial frequencies focus a near paraxial region of the pupil and are affected only slightly by level of Seidel spherical aberration, degree of pupil apodisation and pupil diameter, and generally focused a radius of about 1 to 1.5 mm from the pupil centre. Low spatial frequency refractions focus a marginal region of the pupil, and are significantly affected by level of spherical aberration, amount of pupil apodisation, and pupil size. Clinical refractions that employ the “darker” or “sharper” subjective criteria bias the patient to use lower or higher spatial frequencies respectively. Conclusions In the presence of significant levels of spherical aberration, the pupil size independence of subjective refractions occurs with or without Stiles Crawford apodisation for refractions that optimise high spatial frequency content in the image. If low spatial frequencies are optimised by a subjective refraction, spherical refractive error varies with spherical aberration, pupil size, and level of apodisation. As light levels drop from photopic to scotopic, therefore, we expect a shift from pupil size independent to pupil size dependent subjective refractions. Emphasising a “sharper” criterion during subjective refractions will improve image quality for high spatial frequencies and generate pupil size independent refractions. PMID:24397356

  18. Patient age, refractive index of the corneal stroma, and outcomes of uneventful laser in situ keratomileusis.

    PubMed

    Patel, Sudi; Alió, Jorge L; Walewska, Anna; Amparo, Francisco; Artola, Alberto

    2013-03-01

    To determine the influence of age and the corneal stromal refractive index on the difference between the predicted and actual postoperative refractive error after laser in situ keratomileusis (LASIK) and whether the precision of outcomes could be improved by considering age and the refractive index. Vissum Instituto Oftalmologico de Alicante, Alicante, Spain. Case series. Flaps were created using a mechanical microkeratome. The stromal refractive index was measured using a VCH-1 refractometer after flap lifting. Refractive data were obtained 1, 3, and 6 months postoperatively. Uneventful LASIK was performed in 133 eyes. The mean age, refractive index, and applied corrections were 33.4 years ± 9.49 (SD), 1.368 ± 0.006, and -2.43 ± 3.36 diopters (D), respectively. The difference between the predicted and actual postoperative refractive error = 2.315-0.021 age-1.106 refractive index (F = 3.647, r = 0.254, P=.029; n = 109) at 1 month and = 11.820-0.023 age-7.976 refractive index (F = 3.392, r = 0.261, P=.022, n = 106) at 3 months. A correlation between the actual and calculated postoperative refraction improved from r = -0.178 (P=.064; n = 75) to r = -0.418 (P<.001) after considering the true refractive index 6 months postoperatively. The predicted outcomes of LASIK can be improved by inputting the refractive index of the individual corneal stroma. Unexpected outcomes (>0.50 D) of LASIK could be avoided by considering patient age and the refractive index and by adjusting the applied correction accordingly. Copyright © 2012 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  19. Refractive Lenticule Implantation for Correction of Ametropia: Case Reports and Literature Review.

    PubMed

    Lazaridis, A; Messerschmidt-Roth, A; Sekundo, W; Schulze, S

    2017-01-01

    The ReLEx® technique allows correction of refractive errors through the creation and extraction of refractive stromal lenticules. Contrary to excimer laser corneal refractive procedures, where the stromal tissue is photoablated, the extracted lenticules obtained with ReLEx® can be preserved. Recent studies and case reports have described autologous re-implantation and allogeneic implantation of refractive lenticules into femtosecond-laser created stromal pockets in order to reverse the refractive outcome of a myopic corneal refractive procedure, correct hyperopia, aphakia, presbyopia and treat keratoconus. The use of stromal lenticules has also been described for therapeutic purposes, with an allogenic lenticule being transplanted under a LASIK flap in order to restore corneal volume and reduce the refractive error in a case of excessive stromal tissue removal after LASIK. This review summarises the results of the latest case reports and studies that describe the implantation of cryopreserved or fresh refractive stromal lenticules and discusses the feasibility, safety and refractive outcomes of the procedure, on the basis of published literature as well as our own experience. Georg Thieme Verlag KG Stuttgart · New York.

  20. Comparison of the VISX wavescan and OPD-scan III with the subjective refraction.

    PubMed

    Zhu, R; Long, K-L; Wu, X-M; Li, Q-D

    2016-07-01

    To compare the refractive errors measured by the VISX WaveScan, OPD-Scan III and the subjective refraction. The optometry accuracy of computer operated aberrometer used before refractive surgery has been debatable. Hence, a clear study on the role of such automated equipment in optometry is the need of the hour as compared to subjective refraction. Seventy-six patients (152 eyes) were recruited from January 2013 to December 2013. All patients were measured with subjective refraction by the phoropter (NIDEK, RT-5100), objective refraction by the WaveScan (AMO Company, USA), OPD-Scan III (Nidek Technologies, Japan). The sphere, cylinder, axis of the three methods were compared and analyzed. The diopter of sphere power measured by WaveScan was lower than that of the subjective refraction and the difference was 0.13 ± 0. 30D (t = 3. 753, p <0. 001). While the diopter of cylinder power was higher and the difference was 0.13 ±0.43D (t = 3. 664, p <0. 001). There was no significance for sphere, cylinder and spherical equivalent between OPD-Scan III and subjective refraction (p >0. 05). The value of the difference between WaveScan and subjective refraction was 5.87°±6.19°on average, while the difference between OPD-Scan III and subjective refraction was 3.82°±3.95°on average. The differences between the two were statistically significant (t =2. 817, p =0. 006). The results of sphere and cylinder measured by WaveScan and subjective refraction were different. As the latest integrated equipment, the Nidek OPD-Scan III gives a more accurate measurement of objective refraction when compared with subjective refraction. The latest Nidek OPD-Scan III may prove to be an useful tool for preoperative optometry deviation based on objective refraction.

  1. Wave-vector and polarization dependence of conical refraction.

    PubMed

    Turpin, A; Loiko, Yu V; Kalkandjiev, T K; Tomizawa, H; Mompart, J

    2013-02-25

    We experimentally address the wave-vector and polarization dependence of the internal conical refraction phenomenon by demonstrating that an input light beam of elliptical transverse profile refracts into two beams after passing along one of the optic axes of a biaxial crystal, i.e. it exhibits double refraction instead of refracting conically. Such double refraction is investigated by the independent rotation of a linear polarizer and a cylindrical lens. Expressions to describe the position and the intensity pattern of the refracted beams are presented and applied to predict the intensity pattern for an axicon beam propagating along the optic axis of a biaxial crystal.

  2. Autorefraction, Retinoscopy, Javal's Rule, and Grosvenor's Modified Javal's Rule: The Best Predictor of Refractive Astigmatism

    PubMed Central

    Asiedu, Kofi; Ampiah, Emmanuel Ekow

    2016-01-01

    The aim of the study was to determine the level of agreement between Javal's rule, autorefraction, retinoscopy, and refractive astigmatism and to determine which technique is the most suitable substitute when subjective refraction is not applicable using a clinical sample. A total of 36 subjects, 14 males and 22 females, were involved in this study. The intraclass correlation coefficients between subjective refraction, autorefraction, and retinoscopy were 0.895 and 0.989, respectively, for the spherical equivalent. The Bland-Altman 95% limits of agreement between subjective refraction and autorefraction; subjective refraction and retinoscopy; and autorefraction and retinoscopy were −2.84 to 3.58, −0.88 to 1.12, and −3.01 to 3.53, respectively, for the spherical equivalent. The intraclass correlation coefficients between spectacle total astigmatism and the following techniques were as follows: retinoscopy (0.85); autorefraction (0.92); Javal's rule (0.82); and Grosvenor et al. version (0.85). The Bland-Altman 95% limits of agreement between subjective refraction and autorefraction; subjective refraction and retinoscopy; subjective refraction and Javal's rule; and subjective refraction and Grosvenor et al. version were −0.87 to 1.25, −1.49 to 1.99, −0.73 to 1.93, and −0.89 to 1.7, respectively, for the total astigmatism. The study showed that autorefraction and Javal's rule may provide a starting point for subjective refraction cylinder power determination but only retinoscopy may satisfactorily replace subjective refraction total astigmatism when subjective refraction is not applicable. PMID:27803811

  3. Refraction in Adults with Diabetes

    PubMed Central

    Klein, Barbara E. K.; Lee, Kristine E.; Klein, Ronald

    2010-01-01

    Objective(s) Examine refraction, change in refraction, and risk factors for change in refraction in adults with type 1 and type 2 diabetes. Methods Population based study. Modified Early Treatment of Diabetic Retinopathy Study refractions and a standard history were obtained for all participants. Baseline and ten-year follow-up data were available. Results Age was significantly associated with refraction in persons with younger-onset diabetes (T1D) and those with older-onset diabetes (T2D); refractions were similar for both groups. Persons of similar age with T1D were likely to be more myopic than those with T2D (P<.01). Years of education were significantly associated with more myopic refraction (P<.0001). In those with T1D on average there was a −.35 diopter (D) change in refraction over 10 years. However, there was a systematic decrease in myopic shift with increasing age at baseline. Those with longer duration of diabetes and with proliferative retinopathy were more likely to have hyperopic shifts in refraction. In those with T2D there was, on average, a +.25D change in refraction over the 10 years but there was little consistency in the amount of change by age at baseline. There were no other significant effects on change in refraction in this group. Conclusions In persons of similar age, those with T1D are likely to be slightly more myopic than those with T2D. Overall, mean refractions and the important risk factors of age and education are similar to those reported in non-diabetic populations. PMID:21220629

  4. Autonomous satellite navigation using starlight refraction angle measurements

    NASA Astrophysics Data System (ADS)

    Ning, Xiaolin; Wang, Longhua; Bai, Xinbei; Fang, Jiancheng

    2013-05-01

    An on-board autonomous navigation capability is required to reduce the operation costs and enhance the navigation performance of future satellites. Autonomous navigation by stellar refraction is a type of autonomous celestial navigation method that uses high-accuracy star sensors instead of Earth sensors to provide information regarding Earth's horizon. In previous studies, the refraction apparent height has typically been used for such navigation. However, the apparent height cannot be measured directly by a star sensor and can only be calculated by the refraction angle and an atmospheric refraction model. Therefore, additional errors are introduced by the uncertainty and nonlinearity of atmospheric refraction models, which result in reduced navigation accuracy and reliability. A new navigation method based on the direct measurement of the refraction angle is proposed to solve this problem. Techniques for the determination of the refraction angle are introduced, and a measurement model for the refraction angle is established. The method is tested and validated by simulations. When the starlight refraction height ranges from 20 to 50 km, a positioning accuracy of better than 100 m can be achieved for a low-Earth-orbit (LEO) satellite using the refraction angle, while the positioning accuracy of the traditional method using the apparent height is worse than 500 m under the same conditions. Furthermore, an analysis of the factors that affect navigation accuracy, including the measurement accuracy of the refraction angle, the number of visible refracted stars per orbit and the installation azimuth of star sensor, is presented. This method is highly recommended for small satellites in particular, as no additional hardware besides two star sensors is required.

  5. Peripheral refraction profiles in subjects with low foveal refractive errors.

    PubMed

    Tabernero, Juan; Ohlendorf, Arne; Fischer, M Dominik; Bruckmann, Anna R; Schiefer, Ulrich; Schaeffel, Frank

    2011-03-01

    To study the variability of peripheral refraction in a population of 43 subjects with low foveal refractive errors. A scan of the refractive error in the vertical pupil meridian of the right eye of 43 subjects (age range, 18 to 80 years, foveal spherical equivalent, < ± 2.5 diopter) over the central ± 45° of the visual field was performed using a recently developed angular scanning photorefractor. Refraction profiles across the visual field were fitted with four different models: (1) "flat model" (refractions about constant across the visual field), (2) "parabolic model" (refractions follow about a parabolic function), (3) "bi-linear model" (linear change of refractions with eccentricity from the fovea to the periphery), and (4) "box model" ("flat" central area with a linear change in refraction from a certain peripheral angle). Based on the minimal residuals of each fit, the subjects were classified into one of the four models. The "box model" accurately described the peripheral refractions in about 50% of the subjects. Peripheral refractions in six subjects were better characterized by a "linear model," in eight subjects by a "flat model," and in eight by the "parabolic model." Even after assignment to one of the models, the variability remained strikingly large, ranging from -0.75 to 6 diopter in the temporal retina at 45° eccentricity. The most common peripheral refraction profile (observed in nearly 50% of our population) was best described by the "box model." The high variability among subjects may limit attempts to reduce myopia progression with a uniform lens design and may rather call for a customized approach.

  6. Headaches associated with refractive errors: myth or reality?

    PubMed

    Gil-Gouveia, R; Martins, I P

    2002-04-01

    Headache and refractive errors are very common conditions in the general population, and those with headache often attribute their pain to a visual problem. The International Headache Society (IHS) criteria for the classification of headache includes an entity of headache associated with refractive errors (HARE), but indicates that its importance is widely overestimated. To compare overall headache frequency and HARE frequency in healthy subjects with uncorrected or miscorrected refractive errors and a control group. We interviewed 105 individuals with uncorrected refractive errors and a control group of 71 subjects (with properly corrected or without refractive errors) regarding their headache history. We compared the occurrence of headache and its diagnosis in both groups and assessed its relation to their habits of visual effort and type of refractive errors. Headache frequency was similar in both subjects and controls. Headache associated with refractive errors was the only headache type significantly more common in subjects with refractive errors than in controls (6.7% versus 0%). It was associated with hyperopia and was unrelated to visual effort or to the severity of visual error. With adequate correction, 72.5% of the subjects with headache and refractive error reported improvement in their headaches, and 38% had complete remission of headache. Regardless of the type of headache present, headache frequency was significantly reduced in these subjects (t = 2.34, P =.02). Headache associated with refractive errors was rarely identified in individuals with refractive errors. In those with chronic headache, proper correction of refractive errors significantly improved headache complaints and did so primarily by decreasing the frequency of headache episodes.

  7. Repeatability and Reproducibility of Virtual Subjective Refraction.

    PubMed

    Perches, Sara; Collados, M Victoria; Ares, Jorge

    2016-10-01

    To establish the repeatability and reproducibility of a virtual refraction process using simulated retinal images. With simulation software, aberrated images corresponding with each step of the refraction process were calculated following the typical protocol of conventional subjective refraction. Fifty external examiners judged simulated retinal images until the best sphero-cylindrical refraction and the best visual acuity were achieved starting from the aberrometry data of three patients. Data analyses were performed to assess repeatability and reproducibility of the virtual refraction as a function of pupil size and aberrometric profile of different patients. SD values achieved in three components of refraction (M, J0, and J45) are lower than 0.25D in repeatability analysis. Regarding reproducibility, we found SD values lower than 0.25D in the most cases. When the results of virtual refraction with different pupil diameters (4 and 6 mm) were compared, the mean of differences (MoD) obtained were not clinically significant (less than 0.25D). Only one of the aberrometry profiles with high uncorrected astigmatism shows poor results for the M component in reproducibility and pupil size dependence analysis. In all cases, vision achieved was better than 0 logMAR. A comparison between the compensation obtained with virtual and conventional subjective refraction was made as an example of this application, showing good quality retinal images in both processes. The present study shows that virtual refraction has similar levels of precision as conventional subjective refraction. Moreover, virtual refraction has also shown that when high low order astigmatism is present, the refraction result is less precise and highly dependent on pupil size.

  8. Baseline peripheral refractive error and changes in axial refraction during one year in a young adult population.

    PubMed

    Hartwig, Andreas; Charman, William Neil; Radhakrishnan, Hema

    2016-01-01

    To determine whether the initial characteristics of individual patterns of peripheral refraction relate to subsequent changes in refraction over a one-year period. 54 myopic and emmetropic subjects (mean age: 24.9±5.1 years; median 24 years) with normal vision were recruited and underwent conventional non-cycloplegic subjective refraction. Peripheral refraction was also measured at 5° intervals over the central 60° of horizontal visual field, together with axial length. After one year, measurements of subjective refraction and axial length were repeated on the 43 subjects who were still available for examination. In agreement with earlier studies, higher myopes tended to show greater relative peripheral hyperopia. There was, however, considerable inter-subject variation in the pattern of relative peripheral refractive error (RPRE) at any level of axial refraction. Across the group, mean one-year changes in axial refraction and axial length did not differ significantly from zero. There was no correlation between changes in these parameters for individual subjects and any characteristic of their RPRE. No evidence was found to support the hypothesis that the pattern of RPRE is predictive of subsequent refractive change in this age group. Copyright © 2015 Spanish General Council of Optometry. Published by Elsevier Espana. All rights reserved.

  9. Comparison of Subjective Refraction under Binocular and Monocular Conditions in Myopic Subjects.

    PubMed

    Kobashi, Hidenaga; Kamiya, Kazutaka; Handa, Tomoya; Ando, Wakako; Kawamorita, Takushi; Igarashi, Akihito; Shimizu, Kimiya

    2015-07-28

    To compare subjective refraction under binocular and monocular conditions, and to investigate the clinical factors affecting the difference in spherical refraction between the two conditions. We examined thirty eyes of 30 healthy subjects. Binocular and monocular refraction without cycloplegia was measured through circular polarizing lenses in both eyes, using the Landolt-C chart of the 3D visual function trainer-ORTe. Stepwise multiple regression analysis was used to assess the relations among several pairs of variables and the difference in spherical refraction in binocular and monocular conditions. Subjective spherical refraction in the monocular condition was significantly more myopic than that in the binocular condition (p < 0.001), whereas no significant differences were seen in subjective cylindrical refraction (p = 0.99). The explanatory variable relevant to the difference in spherical refraction between binocular and monocular conditions was the binocular spherical refraction (p = 0.032, partial regression coefficient B = 0.029) (adjusted R(2) = 0.230). No significant correlation was seen with other clinical factors. Subjective spherical refraction in the monocular condition was significantly more myopic than that in the binocular condition. Eyes with higher degrees of myopia are more predisposed to show the large difference in spherical refraction between these two conditions.

  10. Comparison of Subjective Refraction under Binocular and Monocular Conditions in Myopic Subjects

    PubMed Central

    Kobashi, Hidenaga; Kamiya, Kazutaka; Handa, Tomoya; Ando, Wakako; Kawamorita, Takushi; Igarashi, Akihito; Shimizu, Kimiya

    2015-01-01

    To compare subjective refraction under binocular and monocular conditions, and to investigate the clinical factors affecting the difference in spherical refraction between the two conditions. We examined thirty eyes of 30 healthy subjects. Binocular and monocular refraction without cycloplegia was measured through circular polarizing lenses in both eyes, using the Landolt-C chart of the 3D visual function trainer-ORTe. Stepwise multiple regression analysis was used to assess the relations among several pairs of variables and the difference in spherical refraction in binocular and monocular conditions. Subjective spherical refraction in the monocular condition was significantly more myopic than that in the binocular condition (p < 0.001), whereas no significant differences were seen in subjective cylindrical refraction (p = 0.99). The explanatory variable relevant to the difference in spherical refraction between binocular and monocular conditions was the binocular spherical refraction (p = 0.032, partial regression coefficient B = 0.029) (adjusted R2 = 0.230). No significant correlation was seen with other clinical factors. Subjective spherical refraction in the monocular condition was significantly more myopic than that in the binocular condition. Eyes with higher degrees of myopia are more predisposed to show the large difference in spherical refraction between these two conditions. PMID:26218972

  11. The distribution of refractive errors among children attending Lumbini Eye Institute, Nepal.

    PubMed

    Rai, S; Thapa, H B; Sharma, M K; Dhakhwa, K; Karki, R

    2012-01-01

    Uncorrected refractive error is an important cause of childhood blindness and visual impairment. To describe the patterns of refractive errors among children attending the outpatient clinic at the Department of Pediatric Ophthalmology, Lumbini Eye Institute, Bhairahawa, Nepal. Records of 133 children with refractive errors aged 5 - 15 years from both the urban and rural areas of Nepal and the adjacent territory of India attending the hospital between September and November 2010 were examined for patterns of refractive errors. The SPSS statistical software was used to perform data analysis. The commonest type of refractive error among the children was astigmatism (47 %) followed by myopia (34 %) and hyperopia (15 %). The refractive error was more prevalent among children of both the genders of age group 11-15 years as compared to their younger counterparts (RR = 1.22, 95 % CI = 0.66 - 2.25). The refractive error was more common (70 %) in the rural than the urban children (26 %). The rural females had a higher (38 %) prevalence of myopia than urban females (18 %). Among the children with refractive errors, only 57 % were using spectacles at the initial presentation. Astigmatism is the commonest type of refractive error among the children of age 5 - 15 years followed by hypermetropia and myopia. Refractive error remains uncorrected in a significant number of children. © NEPjOPH.

  12. Headache and refractive errors in children.

    PubMed

    Roth, Zachary; Pandolfo, Katie R; Simon, John; Zobal-Ratner, Jitka

    2014-01-01

    To investigate the association between uncorrected or miscorrected refractive errors in children and headache, and to determine whether correction of refractive errors contributes to headache resolution. Results of ophthalmic examination, including refractive error, were recorded at initial visit for headache. If resolution of headache on subsequent visits was not documented, a telephone call was placed to their caregivers to inquire whether headache had resolved. Of the 158 patients, 75.3% had normal or unchanged eye examinations, including refractions.Follow-up data were available for 110 patients. Among those, 32 received new or changed spectacle correction and 78 did not require a change in refraction.Headaches improved in 76.4% of all patients, whether with (71.9%) or without (78.2%) a change in refractive correction. The difference between these two groups was not statistically significant (P = .38). Headaches in children usually do not appear to be caused by ophthalmic disease, including refractive error. The prognosis for improvement is favorable, regardless of whether refractive correction is required. Copyright 2014, SLACK Incorporated.

  13. Plasmonic nanoshell functionalized etched fiber Bragg gratings for highly sensitive refractive index measurements.

    PubMed

    Burgmeier, Jörg; Feizpour, Amin; Schade, Wolfgang; Reinhard, Björn M

    2015-02-15

    A novel fiber optical refractive index sensor based on gold nanoshells immobilized on the surface of an etched single-mode fiber including a Bragg grating is demonstrated. The nanoparticle coating induces refractive index dependent waveguide losses, because of the variation of the evanescently guided part of the light. Hence the amplitude of the Bragg reflection is highly sensitive to refractive index changes of the surrounding medium. The nanoshell functionalized fiber optical refractive index sensor works in reflectance mode, is suitable for chemical and biochemical sensing, and shows an intensity dependency of 4400% per refractive index unit in the refractive index range between 1.333 and 1.346. Furthermore, the physical length of the sensor is smaller than 3 mm with a diameter of 6 μm, and therefore offers the possibility of a localized refractive index measurement.

  14. Refractive eye surgery in treating functional amblyopia in children.

    PubMed

    Levenger, Samuel; Nemet, Pinhas; Hirsh, Ami; Kremer, Israel; Nemet, Arie

    2006-01-01

    While excimer laser refractive surgery is recommended and highly successful for correcting refractive errors in adults, its use in children has not been extensively exercised or studied. We report our experience treating children with amblyopia due to high anisometropia, high astigmatism, high myopia and with associated developmental delay. Review of patient records of our refractive clinic. A retrospective review was made of all 11 children with stable refractive errors who were unsuccessfully treated non-surgically and then underwent corneal refractive surgery and in one case, lenticular surgery. Seven had high myopic anisometropia, 2 had high astigmatism, and two had high myopia--one with Down's Syndrome and one with agenesis of the corpus callosum. The surgical refractive treatment eliminated or reduced the anisometropia, reduced the astigmatic error, improved vision and improved the daily function of the children with developmental delay. There were no complications or untoward results. Refractive surgery is safe and effective in treating children with high myopic anisometropia, high astigmatism, high myopia and developmental delay due to the resulting poor vision. Surgery can improve visual acuity in amblyopia not responding to routine treatment by correcting the refractive error and refractive aberrations.

  15. Optical negative refraction by four-wave mixing in thin metallic nanostructures.

    PubMed

    Palomba, Stefano; Zhang, Shuang; Park, Yongshik; Bartal, Guy; Yin, Xiaobo; Zhang, Xiang

    2011-10-30

    The law of refraction first derived by Snellius and later introduced as the Huygens-Fermat principle, states that the incidence and refracted angles of a light wave at the interface of two different materials are related to the ratio of the refractive indices in each medium. Whereas all natural materials have a positive refractive index and therefore exhibit refraction in the positive direction, artificially engineered negative index metamaterials have been shown capable of bending light waves negatively. Such a negative refractive index is the key to achieving a perfect lens that is capable of imaging well below the diffraction limit. However, negative index metamaterials are typically lossy, narrow band, and require complicated fabrication processes. Recently, an alternative approach to obtain negative refraction from a very thin nonlinear film has been proposed and experimentally demonstrated in the microwave region. However, such approaches use phase conjugation, which makes optical implementations difficult. Here, we report a simple but different scheme to demonstrate experimentally nonlinear negative refraction at optical frequencies using four-wave mixing in nanostructured metal films. The refractive index can be designed at will by simply tuning the wavelengths of the interacting waves, which could have potential impact on many important applications, such as superlens imaging.

  16. The prediction of zenith range refraction from surface measurements of meteorological parameters. [mathematical models of atmospheric refraction used to improve spacecraft tracking space navigation

    NASA Technical Reports Server (NTRS)

    Berman, A. L.

    1976-01-01

    In the last two decades, increasingly sophisticated deep space missions have placed correspondingly stringent requirements on navigational accuracy. As part of the effort to increase navigational accuracy, and hence the quality of radiometric data, much effort has been expended in an attempt to understand and compute the tropospheric effect on range (and hence range rate) data. The general approach adopted has been that of computing a zenith range refraction, and then mapping this refraction to any arbitrary elevation angle via an empirically derived function of elevation. The prediction of zenith range refraction derived from surface measurements of meteorological parameters is presented. Refractivity is separated into wet (water vapor pressure) and dry (atmospheric pressure) components. The integration of dry refractivity is shown to be exact. Attempts to integrate wet refractivity directly prove ineffective; however, several empirical models developed by the author and other researchers at JPL are discussed. The best current wet refraction model is here considered to be a separate day/night model, which is proportional to surface water vapor pressure and inversely proportional to surface temperature. Methods are suggested that might improve the accuracy of the wet range refraction model.

  17. Differences between wavefront and subjective refraction for infrared light.

    PubMed

    Teel, Danielle F W; Jacobs, Robert J; Copland, James; Neal, Daniel R; Thibos, Larry N

    2014-10-01

    To determine the accuracy of objective wavefront refractions for predicting subjective refractions for monochromatic infrared light. Objective refractions were obtained with a commercial wavefront aberrometer (COAS, Wavefront Sciences). Subjective refractions were obtained for 30 subjects with a speckle optometer validated against objective Zernike wavefront refractions on a physical model eye (Teel et al., Design and validation of an infrared Badal optometer for laser speckle, Optom Vis Sci 2008;85:834-42). Both instruments used near-infrared (NIR) radiation (835 nm for COAS, 820 nm for the speckle optometer) to avoid correction for ocular chromatic aberration. A 3-mm artificial pupil was used to reduce complications attributed to higher-order ocular aberrations. For comparison with paraxial (Seidel) and minimum root-mean-square (Zernike) wavefront refractions, objective refractions were also determined for a battery of 29 image quality metrics by computing the correcting lens that optimizes retinal image quality. Objective Zernike refractions were more myopic than subjective refractions for 29 of 30 subjects. The population mean discrepancy was -0.26 diopters (D) (SEM = 0.03 D). Paraxial (Seidel) objective refractions tended to be hyperopically biased (mean discrepancy = +0.20 D, SEM = 0.06 D). Refractions based on retinal image quality were myopically biased for 28 of 29 metrics. The mean bias across all 31 measures was -0.24 D (SEM = 0.03). Myopic bias of objective refractions was greater for eyes with brown irises compared with eyes with blue irises. Our experimental results are consistent with the hypothesis that reflected NIR light captured by the aberrometer originates from scattering sources located posterior to the entrance apertures of cone photoreceptors, near the retinal pigment epithelium. The larger myopic bias for brown eyes suggests that a greater fraction of NIR light is reflected from choroidal melanin in brown eyes compared with blue eyes.

  18. Linkage analysis of quantitative refraction and refractive errors in the Beaver Dam Eye Study.

    PubMed

    Klein, Alison P; Duggal, Priya; Lee, Kristine E; Cheng, Ching-Yu; Klein, Ronald; Bailey-Wilson, Joan E; Klein, Barbara E K

    2011-07-13

    Refraction, as measured by spherical equivalent, is the need for an external lens to focus images on the retina. While genetic factors play an important role in the development of refractive errors, few susceptibility genes have been identified. However, several regions of linkage have been reported for myopia (2q, 4q, 7q, 12q, 17q, 18p, 22q, and Xq) and for quantitative refraction (1p, 3q, 4q, 7p, 8p, and 11p). To replicate previously identified linkage peaks and to identify novel loci that influence quantitative refraction and refractive errors, linkage analysis of spherical equivalent, myopia, and hyperopia in the Beaver Dam Eye Study was performed. Nonparametric, sibling-pair, genome-wide linkage analyses of refraction (spherical equivalent adjusted for age, education, and nuclear sclerosis), myopia and hyperopia in 834 sibling pairs within 486 extended pedigrees were performed. Suggestive evidence of linkage was found for hyperopia on chromosome 3, region q26 (empiric P = 5.34 × 10(-4)), a region that had shown significant genome-wide evidence of linkage to refraction and some evidence of linkage to hyperopia. In addition, the analysis replicated previously reported genome-wide significant linkages to 22q11 of adjusted refraction and myopia (empiric P = 4.43 × 10(-3) and 1.48 × 10(-3), respectively) and to 7p15 of refraction (empiric P = 9.43 × 10(-4)). Evidence was also found of linkage to refraction on 7q36 (empiric P = 2.32 × 10(-3)), a region previously linked to high myopia. The findings provide further evidence that genes controlling refractive errors are located on 3q26, 7p15, 7p36, and 22q11.

  19. Effect of single vision soft contact lenses on peripheral refraction.

    PubMed

    Kang, Pauline; Fan, Yvonne; Oh, Kelly; Trac, Kevin; Zhang, Frank; Swarbrick, Helen

    2012-07-01

    To investigate changes in peripheral refraction with under-, full, and over-correction of central refraction with commercially available single vision soft contact lenses (SCLs) in young myopic adults. Thirty-four myopic adult subjects were fitted with Proclear Sphere SCLs to under-correct (+0.75 DS), fully correct, and over-correct (-0.75 DS) their manifest central refractive error. Central and peripheral refraction were measured with no lens wear and subsequently with different levels of SCL central refractive error correction. The uncorrected refractive error was myopic at all locations along the horizontal meridian. Peripheral refraction was relatively hyperopic compared to center at 30 and 35° in the temporal visual field (VF) in low myopes and at 30 and 35° in the temporal VF and 10, 30, and 35° in the nasal VF in moderate myopes. All levels of SCL correction caused a hyperopic shift in refraction at all locations in the horizontal VF. The smallest hyperopic shift was demonstrated with under-correction followed by full correction and then by over-correction of central refractive error. An increase in relative peripheral hyperopia was measured with full correction SCLs compared with no correction in both low and moderate myopes. However, no difference in relative peripheral refraction profiles were found between under-, full, and over-correction. Under-, full, and over-correction of central refractive error with single vision SCLs caused a hyperopic shift in both central and peripheral refraction at all positions in the horizontal meridian. All levels of SCL correction caused the peripheral retina, which initially experienced absolute myopic defocus at baseline with no correction, to experience absolute hyperopic defocus. This peripheral hyperopia may be a possible cause of myopia progression reported with different types and levels of myopia correction.

  20. The Association between Maternal Reproductive Age and Progression of Refractive Error in Urban Students in Beijing

    PubMed Central

    Vasudevan, Balamurali; Jin, Zi Bing; Ciuffreda, Kenneth J.; Jhanji, Vishal; Zhou, Hong Jia; Wang, Ning Li; Liang, Yuan Bo

    2015-01-01

    Purpose To investigate the association between maternal reproductive age and their children’ refractive error progression in Chinese urban students. Methods The Beijing Myopia Progression Study was a three-year cohort investigation. Cycloplegic refraction of these students at both baseline and follow-up vision examinations, as well as non-cycloplegic refraction of their parents at baseline, were performed. Student’s refractive change was defined as the cycloplegic spherical equivalent (SE) of the right eye at the final follow-up minus the cycloplegic SE of the right eye at baseline. Results At the final follow-up, 241 students (62.4%) were reexamined. 226 students (58.5%) with completed refractive data, as well as completed parental reproductive age data, were enrolled. The average paternal and maternal age increased from 29.4 years and 27.5 years in 1993–1994 to 32.6 years and 29.2 years in 2003–2004, respectively. In the multivariate analysis, students who were younger (β = 0.08 diopter/year/year, P<0.001), with more myopic refraction at baseline (β = 0.02 diopter/year/diopter, P = 0.01), and with older maternal reproductive age (β = -0.18 diopter/year/decade, P = 0.01), had more myopic refractive change. After stratifying the parental reproductive age into quartile groups, children with older maternal reproductive age (trend test: P = 0.04) had more myopic refractive change, after adjusting for the children's age, baseline refraction, maternal refraction, and near work time. However, no significant association between myopic refractive change and paternal reproductive age was found. Conclusions In this cohort, children with older maternal reproductive age had more myopic refractive change. This new risk factor for myopia progression may partially explain the faster myopic progression found in the Chinese population in recent decades. PMID:26421841

  1. High refractive index and temperature sensitivity LPGs for high temperature operation

    NASA Astrophysics Data System (ADS)

    Nascimento, I. M.; Gouveia, C.; Jana, Surnimal; Bera, Susanta; Baptista, J. M.; Moreira, Paulo; Biwas, Palas; Bandyopadhyay, Somnath; Jorge, Pedro A. S.

    2013-11-01

    A fiber optic sensor for high sensitivity refractive index and temperature measurement able to withstand temperature up to 450 °C is reported. Two identical LPG gratings were fabricated, whereas one was coated with a high refractive index (~1.78) sol-gel thin film in order to increase its sensitivity to the external refractive index. The two sensors were characterized and compared in refractive index and temperature. Sensitivities of 1063 nm/RIU (1.338 - 1.348) and 260 pm/°C were achieved for refractive index and temperature, respectively.

  2. Fermat's principle and the formal equivalence of local light-ray rotation and refraction at the interface between homogeneous media with a complex refractive index ratio.

    PubMed

    Sundar, Bhuvanesh; Hamilton, Alasdair C; Courtial, Johannes

    2009-02-01

    We derive a formal description of local light-ray rotation in terms of complex refractive indices. We show that Fermat's principle holds, and we derive an extended Snell's law. The change in the angle of a light ray with respect to the normal of a refractive index interface is described by the modulus of the refractive index ratio; the rotation around the interface normal is described by the argument of the refractive index ratio.

  3. Optofluidic two-dimensional grating volume refractive index sensor.

    PubMed

    Sarkar, Anirban; Shivakiran Bhaktha, B N; Khastgir, Sugata Pratik

    2016-09-10

    We present an optofluidic reservoir with a two-dimensional grating for a lab-on-a-chip volume refractive index sensor. The observed diffraction pattern from the device resembles the analytically obtained fringe pattern. The change in the diffraction pattern has been monitored in the far-field for fluids with different refractive indices. Reliable measurements of refractive index variations, with an accuracy of 6×10-3 refractive index units, for different fluids establishes the optofluidic device as a potential on-chip tool for monitoring dynamic refractive index changes.

  4. Optical Coherence Tomography Accurately Measures Corneal Power Change From Laser Refractive Surgery

    PubMed Central

    McNabb, Ryan P.; Farsiu, Sina; Stinnett, Sandra S.; Izatt, Joseph A.; Kuo, Anthony N.

    2014-01-01

    Purpose To determine the ability of motion corrected optical coherence tomography (OCT) to measure the corneal refractive power change due to laser in situ keratomileusis (LASIK). Design Evaluation of a diagnostic test or technology in a cohort. Subjects 70 eyes from 37 subjects undergoing LASIK were measured preoperatively. 39 eyes from 22 subjects were measured postoperatively and completed the study. Methods Consecutive patients undergoing LASIK at the Duke Eye Center who consented to participate were imaged with Placido-ring topography, Scheimpflug photography and OCT on the day of their surgery. Patients were then reimaged with the same imaging systems at the post-operative month 3 visit. Change in pre- to post-operative corneal refractive power as measured by each of the imaging modalities was compared to the pre- to post-operative change in manifest refraction using t-test with generalized estimating equations. Main Outcome Measures Corneal refractive power change due to LASIK as measured by Placido-ring topography, Scheimpflug Photography, and OCT compared to the manifest refraction change vertexed to the corneal plane. The change in manifest refraction should correspond to the change in the corneal refractive power from LASIK and was considered the reference measurement. Results In 22 returning post-LASIK individuals (39 eyes), we found no significant difference between the clinically measured pre to post LASIK change in manifest refraction and both Scheimpflug photography (p = 0.714) and OCT (p = 0.216). In contrast, keratometry values from Placido-ring topography were found to be significantly different from the measured refractive change (p < 0.001). Additionally, of the three imaging modalities, OCT recorded the smallest mean absolute difference from the reference measurement with the least amount of variability. Conclusion Motion corrected OCT more accurately measures the change in corneal refractive power due to laser refractive surgery than currently available clinical devices. By offering accurate corneal refractive power measurements in normal and surgically modified subjects, OCT offers a compelling alternative to current clinical devices for determining corneal refractive power. PMID:25487424

  5. Refraction in exoplanet atmospheres. Photometric signatures, implications for transmission spectroscopy, and search in Kepler data

    NASA Astrophysics Data System (ADS)

    Alp, D.; Demory, B.-O.

    2018-01-01

    Context. Refraction deflects photons that pass through atmospheres, which affects transit light curves. Refraction thus provides an avenue to probe physical properties of exoplanet atmospheres and to constrain the presence of clouds and hazes. In addition, an effective surface can be imposed by refraction, thereby limiting the pressure levels probed by transmission spectroscopy. Aims: The main objective of the paper is to model the effects of refraction on photometric light curves for realistic planets and to explore the dependencies on atmospheric physical parameters. We also explore under which circumstances transmission spectra are significantly affected by refraction. Finally, we search for refraction signatures in photometric residuals in Kepler data. Methods: We use the model of Hui & Seager (2002, ApJ, 572, 540) to compute deflection angles and refraction transit light curves, allowing us to explore the parameter space of atmospheric properties. The observational search is performed by stacking large samples of transit light curves from Kepler. Results: We find that out-of-transit refraction shoulders are the most easily observable features, which can reach peak amplitudes of 10 parts per million (ppm) for planets around Sun-like stars. More typical amplitudes are a few ppm or less for Jovians and at the sub-ppm level for super-Earths. In-transit, ingress, and egress refraction features are challenging to detect because of the short timescales and degeneracies with other transit model parameters. Interestingly, the signal-to-noise ratio of any refraction residuals for planets orbiting Sun-like hosts are expected to be similar for planets orbiting red dwarfs and ultra-cool stars. We also find that the maximum depth probed by transmission spectroscopy is not limited by refraction for weakly lensing planets, but that the incidence of refraction can vary significantly for strongly lensing planets. We find no signs of refraction features in the stacked Kepler light curves, which is in agreement with our model predictions.

  6. Influence of stromal refractive index and hydration on corneal laser refractive surgery.

    PubMed

    de Ortueta, Diego; von Rüden, Dennis; Magnago, Thomas; Arba Mosquera, Samuel

    2014-06-01

    To evaluate the influence of the stromal refractive index and hydration on postoperative outcomes in eyes that had corneal laser refractive surgery using the Amaris laser system. Augenzentrum Recklinghausen, Recklinghausen, Germany. Comparative case series. At the 6-month follow-up, right eyes were retrospectively analyzed. The effect of the stromal refractive index and hydration on refractive outcomes was assessed using univariate linear and multilinear correlations. Sixty eyes were analyzed. Univariate linear analyses showed that the stromal refractive index and hydration were correlated with the thickness of the preoperative exposed stroma and was statistically different for laser in situ keratomileusis and laser-assisted subepithelial keratectomy treatments. Univariate multilinear analyses showed that the spherical equivalent (SE) was correlated with the attempted SE and stromal refractive index (or hydration). Analyses suggest overcorrections for higher stromal refractive index values and for lower hydration values. The stromal refractive index and hydration affected postoperative outcomes in a subtle, yet significant manner. An adjustment toward greater attempted correction in highly hydrated corneas and less intended correction in low hydrated corneas might help optimize refractive outcomes. Mr. Magnago and Dr. Arba-Mosquera are employees of and Dr. Diego de Ortueta is a consultant to Schwind eye-tech-solutions GmbH & Co. KG. Mr. Rüden has no financial or proprietary interest in any material or method mentioned. Copyright © 2014 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  7. Fabrication of refractive index distributions in polymer using a photochemical reaction

    NASA Astrophysics Data System (ADS)

    Kada, Takeshi; Obara, Atsushi; Watanabe, Toshiyuki; Miyata, Seizo; Liang, Chuan Xin; Machida, Hideaki; Kiso, Koichi

    2000-01-01

    We demonstrate that a photochemical reaction can create various distributions of refractive index in polymer. When the polymer containing a photochemically active material is irradiated by UV light, the photochemical reaction which breaks the π-conjugated system in the material and decreases its linear polarizability can reduce refractive index of the polymer. We prepared a PMMA film added DMAPN ((4-N,N-dimethylaminophenyl)-N'-phenylnitrone) with a rate of 23 wt % by use of spin coating. Electronic structural change of DMAPN and refractive indices of the film before and after UV irradiation were evaluated by UV absorption spectra and m-line method, respectively. The UV irradiation decreased λmax at 380 nm in the absorption spectra, which is attributed to nitrone, and the refractive indices exponentially with irradiation time. The change of refractive indices reached 0.028. The refractive index profile upon depth of the film was investigated by measuring refractive indices of stacked DMAPN/PMMA films. When UV with a power of 10.7 mW/cm2 irradiated upon three stacked DMAPN/PMMA films for 35 s, variation of the refractive index change showed a quadratic profile. The refractive index profile with various irradiation time can be accounted with the combination of the chemical kinetics with the steady state approximation and Lambert-Beer's law. Thus, the photochemical reaction can be used to control the refractive index distribution in polymer.

  8. Measurement of the Microwave Refractive Index of Materials Based on Parallel Plate Waveguides

    NASA Astrophysics Data System (ADS)

    Zhao, F.; Pei, J.; Kan, J. S.; Zhao, Q.

    2017-12-01

    An electrical field scanning apparatus based on a parallel plate waveguide method is constructed, which collects the amplitude and phase matrices as a function of the relative position. On the basis of such data, a method for calculating the refractive index of the measured wedge samples is proposed in this paper. The measurement and calculation results of different PTFE samples reveal that the refractive index measured by the apparatus is substantially consistent with the refractive index inferred with the permittivity of the sample. The proposed refractive index calculation method proposed in this paper is a competitive method for the characterization of the refractive index of materials with positive refractive index. Since the apparatus and method can be used to measure and calculate arbitrary direction of the microwave propagation, it is believed that both of them can be applied to the negative refractive index materials, such as metamaterials or “left-handed” materials.

  9. Effects of refractive index mismatch in optical CT imaging of polymer gel dosimeters.

    PubMed

    Manjappa, Rakesh; Makki S, Sharath; Kumar, Rajesh; Kanhirodan, Rajan

    2015-02-01

    Proposing an image reconstruction technique, algebraic reconstruction technique-refraction correction (ART-rc). The proposed method takes care of refractive index mismatches present in gel dosimeter scanner at the boundary, and also corrects for the interior ray refraction. Polymer gel dosimeters with high dose regions have higher refractive index and optical density compared to the background medium, these changes in refractive index at high dose results in interior ray bending. The inclusion of the effects of refraction is an important step in reconstruction of optical density in gel dosimeters. The proposed ray tracing algorithm models the interior multiple refraction at the inhomogeneities. Jacob's ray tracing algorithm has been modified to calculate the pathlengths of the ray that traverses through the higher dose regions. The algorithm computes the length of the ray in each pixel along its path and is used as the weight matrix. Algebraic reconstruction technique and pixel based reconstruction algorithms are used for solving the reconstruction problem. The proposed method is tested with numerical phantoms for various noise levels. The experimental dosimetric results are also presented. The results show that the proposed scheme ART-rc is able to reconstruct optical density inside the dosimeter better than the results obtained using filtered backprojection and conventional algebraic reconstruction approaches. The quantitative improvement using ART-rc is evaluated using gamma-index. The refraction errors due to regions of different refractive indices are discussed. The effects of modeling of interior refraction in the dose region are presented. The errors propagated due to multiple refraction effects have been modeled and the improvements in reconstruction using proposed model is presented. The refractive index of the dosimeter has a mismatch with the surrounding medium (for dry air or water scanning). The algorithm reconstructs the dose profiles by estimating refractive indices of multiple inhomogeneities having different refractive indices and optical densities embedded in the dosimeter. This is achieved by tracking the path of the ray that traverses through the dosimeter. Extensive simulation studies have been carried out and results are found to be matching that of experimental results.

  10. Human resources for refraction services in Central Nepal.

    PubMed

    Kandel, Himal; Murthy, G V S; Bascaran, Covadonga

    2015-07-01

    Uncorrected refractive error is a public health problem globally and in Nepal. Planning of refraction services is hampered by a paucity of data. This study was conducted to determine availability and distribution of human resources for refraction, their efficiency, the type and extent of their training; the current service provision of refraction services and the unmet need in human resources for refraction in Central Nepal. This was a descriptive cross-sectional study. All refraction facilities in the Central Region were identified through an Internet search and interviews of key informants from the professional bodies and parent organisations of primary eye centres. A stratified simple random sampling technique was used to select 50 per cent of refraction facilities. The selected facilities were visited for primary data collection. Face-to-face interviews were conducted with the managers and the refractionists available in the facilities using a semi-structured questionnaire. Data was collected in 29 centres. All the managers (n=29; response rate 100 per cent) and 50 refractionists (Response rate 65.8 per cent) were interviewed. Optometrists and ophthalmic assistants were the main providers of refraction services (n=70, 92.11 per cent). They were unevenly distributed across the region, highly concentrated around urban areas. The median number of refractions per refractionist per year was 3,600 (IQR: 2,400 - 6,000). Interviewed refractionists stated that clients' knowledge, attitude and practice related factors such as lack of awareness of the need for refraction services and/or availability of existing services were the major barriers to the output of refraction services. The total number of refractions carried out in the Central Region per year was 653,176. An additional 170 refractionists would be needed to meet the unmet need of 1,323,234 refractions. The study findings demand a major effort to develop appropriately trained personnel when planning refraction services in the Central Region and in Nepal as a whole. The equitable distribution of the refractionists, their community-outreach services and awareness raising activities should be emphasised. © 2015 The Authors. Clinical and Experimental Optometry © 2015 Optometry Australia.

  11. Effects of refractive index mismatch in optical CT imaging of polymer gel dosimeters

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Manjappa, Rakesh; Makki S, Sharath; Kanhirodan, Rajan, E-mail: rajan@physics.iisc.ernet.in

    2015-02-15

    Purpose: Proposing an image reconstruction technique, algebraic reconstruction technique-refraction correction (ART-rc). The proposed method takes care of refractive index mismatches present in gel dosimeter scanner at the boundary, and also corrects for the interior ray refraction. Polymer gel dosimeters with high dose regions have higher refractive index and optical density compared to the background medium, these changes in refractive index at high dose results in interior ray bending. Methods: The inclusion of the effects of refraction is an important step in reconstruction of optical density in gel dosimeters. The proposed ray tracing algorithm models the interior multiple refraction at themore » inhomogeneities. Jacob’s ray tracing algorithm has been modified to calculate the pathlengths of the ray that traverses through the higher dose regions. The algorithm computes the length of the ray in each pixel along its path and is used as the weight matrix. Algebraic reconstruction technique and pixel based reconstruction algorithms are used for solving the reconstruction problem. The proposed method is tested with numerical phantoms for various noise levels. The experimental dosimetric results are also presented. Results: The results show that the proposed scheme ART-rc is able to reconstruct optical density inside the dosimeter better than the results obtained using filtered backprojection and conventional algebraic reconstruction approaches. The quantitative improvement using ART-rc is evaluated using gamma-index. The refraction errors due to regions of different refractive indices are discussed. The effects of modeling of interior refraction in the dose region are presented. Conclusions: The errors propagated due to multiple refraction effects have been modeled and the improvements in reconstruction using proposed model is presented. The refractive index of the dosimeter has a mismatch with the surrounding medium (for dry air or water scanning). The algorithm reconstructs the dose profiles by estimating refractive indices of multiple inhomogeneities having different refractive indices and optical densities embedded in the dosimeter. This is achieved by tracking the path of the ray that traverses through the dosimeter. Extensive simulation studies have been carried out and results are found to be matching that of experimental results.« less

  12. Questionnaires for Measuring Refractive Surgery Outcomes.

    PubMed

    Kandel, Himal; Khadka, Jyoti; Lundström, Mats; Goggin, Michael; Pesudovs, Konrad

    2017-06-01

    To identify the questionnaires used to assess refractive surgery outcomes, assess the available questionnaires in regard to their psychometric properties, validity, and reliability, and evaluate the performance of the available questionnaires in measuring refractive surgery outcomes. An extensive literature search was done on PubMed, MEDLINE, Scopus, CINAHL, Cochrane, and Web of Science databases to identify articles that described or used at least one questionnaire to assess refractive surgery outcomes. The information on content quality, validity, reliability, responsiveness, and psychometric properties was extracted and analyzed based on an extensive set of quality criteria. Eighty-one articles describing 27 questionnaires (12 refractive error-specific, including 4 refractive surgery-specific, 7 vision-but-non-refractive, and 8 generic) were included in the review. Most articles (56, 69.1%) described refractive error-specific questionnaires. The Quality of Life Impact of Refractive Correction (QIRC), the Quality of Vision (QoV), and the Near Activity Visual Questionnaire (NAVQ) were originally constructed using Rasch analysis; others were developed using the Classical Test Theory. The National Eye Institute Refractive Quality of Life questionnaire was the most frequently used questionnaire, but it does not provide a valid measurement. The QoV, QIRC, and NAVQ are the three best existing questionnaires to assess visual symptoms, quality of life, and activity limitations, respectively. This review identified three superior quality questionnaires for measuring different aspects of quality of life in refractive surgery. Clinicians and researchers should choose a questionnaire based on the concept being measured with superior psychometric properties. [J Refract Surg. 2017;33(6):416-424.]. Copyright 2017, SLACK Incorporated.

  13. Refractive states of eyes and associations between ametropia and age, breed, and axial globe length in domestic cats.

    PubMed

    Konrade, Kricket A; Hoffman, Allison R; Ramey, Kelli L; Goldenberg, Ruby B; Lehenbauer, Terry W

    2012-02-01

    To determine the refractive states of eyes in domestic cats and to evaluate correlations between refractive error and age, breed, and axial globe measurements. 98 healthy ophthalmologically normal domestic cats. The refractive state of 196 eyes (2 eyes/cat) was determined by use of streak retinoscopy. Cats were considered ametropic when the mean refractive state was ≥ ± 0.5 diopter (D). Amplitude-mode ultrasonography was used to determine axial globe length, anterior chamber length, and vitreous chamber depth. Mean ± SD refractive state of all eyes was -0.78 ± 1.37 D. Mean refractive error of cats changed significantly as a function of age. Mean refractive state of kittens (≤ 4 months old) was -2.45 ± 1.57 D, and mean refractive state of adult cats (> 1 year old) was -0.39 ± 0.85 D. Mean axial globe length, anterior chamber length, and vitreous chamber depth were 19.75 ± 1.59 mm, 4.66 ± 0.86 mm, and 7.92 ± 0.86 mm, respectively. Correlations were detected between age and breed and between age and refractive states of feline eyes. Mean refractive error changed significantly as a function of age, and kittens had greater negative refractive error than did adult cats. Domestic shorthair cats were significantly more likely to be myopic than were domestic mediumhair or domestic longhair cats. Domestic cats should be included in the animals in which myopia can be detected at a young age, with a likelihood of progression to emmetropia as cats mature.

  14. Denaturation process of laccase in various media by refractive index measurements.

    PubMed

    Saoudi, O; Ghaouar, N; Ben Salah, S; Othman, T

    2017-09-01

    In this work, we are interested in the denaturation process of a laccase from Tramates versicolor via the determination of the refractive index, the refractive index increment and the specific volume in various media. The measurements were carried out using an Abbe refractometer. We have shown that the refractive index increment values obtained from the slope of the variation of the refractive index vs. Concentration are outside the range refractive index increments of proteins. To correct the results, we have followed the theoretical predictions based on the knowledge of the protein refractive index from its amino acids composition. The denaturation process was studied by calculating the specific volume variation where its determination was related to the Gladstone-Dale and the Lorentz-Lorentz models.

  15. 3-D photo-patterning of refractive index structures in photosensitive thin film materials

    DOEpatents

    Potter, Jr., Barrett George; Potter, Kelly Simmons

    2002-01-01

    A method of making a three-dimensional refractive index structure in a photosensitive material using photo-patterning. The wavelengths at which a photosensitive material exhibits a change in refractive index upon exposure to optical radiation is first determined and then a portion of the surface of the photosensitive material is optically irradiated at a wavelength at which the photosensitive material exhibits a change in refractive index using a designed illumination system to produce a three-dimensional refractive index structure. The illumination system can be a micro-lenslet array, a macroscopic refractive lens array, or a binary optic phase mask. The method is a single-step, direct-write procedure to produce a designed refractive index structure.

  16. Refractive index sensor based on the leaky radiation of a microfiber.

    PubMed

    Gao, F; Liu, H; Sheng, C; Zhu, C; Zhu, S N

    2014-05-19

    In this work we present a refractive index sensor based on the leaky radiation of a microfiber. The 5.3um diameter microfiber is fabricated by drawing a commercial optical fiber. When the microfiber is immersed into a liquid with larger refractive index than the effective index of fiber mode, the light will leak out through the leaky radiation process. The variation of refractive index of liquid can be monitored by measuring radiation angle of light. The refractive index sensitivity can be over 400 degree/RIU in theory. In the experiment, the variation value 0.001 of refractive index of liquid around this microfiber can be detected through this technique. This work provides a simple and sensitive method for refractive index sensing application.

  17. Evaluation of internal refraction with the optical path difference scan.

    PubMed

    Muftuoglu, Orkun; Erdem, Uzeyir

    2008-01-01

    To evaluate internal refraction and its relation to other optical properties of the eye across a large range of refractive errors, which can provide useful information for the assessment and design of intraocular lenses and corneal ablation patterns. Cohort study. Three hundred ninety-four eyes of 197 healthy subjects with a mean age of 27+/-7 years (range, 18-42). All eyes underwent optical path difference scans to evaluate corneal topography, whole and internal ocular refraction (determined by the subtraction of corneal refraction from whole ocular refraction), and total and higher-order aberrations (HOAs) were assessed. After the conversion of any spherocylindrical refractive errors to vectorial data (sphere equivalent, blurring strength; cylinder, J(0) [power of Jackson cross cylinder at 90 degrees and 180 degrees] and J45 [power of Jackson cross cylinder at 45 degrees and 135 degrees]), the distribution of internal refraction among refraction groups (high myopes, low to moderate myopes, hyperopes, mixed astigmats, and emmetropes) and relationships between internal refraction, corneal refraction, and wavefront aberrations were analyzed. The compensation relation and its rate between corneal and internal astigmatism was assessed by the compensation factor (CF). Whole ocular power and astigmatism, corneal power and astigmatism, internal power and astigmatism, CF for astigmatic data, location of the highest internal refraction zone, and wavefront aberrations. The highest refraction zone was mostly (90%) located in the center in myopes, whereas it was located at the nasal side (71%) in hyperopes. There was a significant correlation between whole ocular and internal powers (P<0.01), but no correlation was observed between corneal and internal powers (P>0.05). Internal astigmatism was mostly against the rule. The mean CF J(0) was 0.63+/-3.78 and CF J(45) was 0.57+/-2.47. The magnitude of the internal astigmatism under the 3-mm zone was correlated with the magnitude of corneal astigmatism (P<0.05). The distribution of astigmatic CF differed among refraction groups. There were significant correlations between internal power and spherical aberration (P<0.05) and internal cylinder under the 5-mm zone and HOAs (P<0.001). There is a remarkable tilt in internal refraction in hyperopes. Although there is a tendency of undercompensation of the corneal astigmatism by internal astigmatism in the entire group of eyes, the compensation differs among refraction groups.

  18. Prevalence and risk factors of undercorrected refractive errors among Singaporean Malay adults: the Singapore Malay Eye Study.

    PubMed

    Rosman, Mohamad; Wong, Tien Y; Tay, Wan-Ting; Tong, Louis; Saw, Seang-Mei

    2009-08-01

    To describe the prevalence and the risk factors of undercorrected refractive error in an adult urban Malay population. This population-based, cross-sectional study was conducted in Singapore in 3280 Malay adults, aged 40 to 80 years. All individuals were examined at a centralized clinic and underwent standardized interviews and assessment of refractive errors and presenting and best corrected visual acuities. Distance presenting visual acuity was monocularly measured by using a logarithm of the minimum angle of resolution (logMAR) number chart at a distance of 4 m, with the participants wearing their "walk-in" optical corrections (spectacles or contact lenses), if any. Refraction was determined by subjective refraction by trained, certified study optometrists. Best corrected visual acuity was monocularly assessed and recorded in logMAR scores using the same test protocol as was used for presenting visual acuity. Undercorrected refractive error was defined as an improvement of at least 0.2 logMAR (2 lines equivalent) in the best corrected visual acuity compared with the presenting visual acuity in the better eye. The mean age of the subjects included in our study was 58 +/- 11 years, and 52% of the subjects were women. The prevalence rate of undercorrected refractive error among Singaporean Malay adults in our study (n = 3115) was 20.4% (age-standardized prevalence rate, 18.3%). More of the women had undercorrected refractive error than the men (21.8% vs. 18.8%, P = 0.04). Undercorrected refractive error was also more common in subjects older than 50 years than in subjects aged 40 to 49 years (22.6% vs. 14.3%, P < 0.001). Non-spectacle wearers were more likely to have undercorrected refractive errors than were spectacle wearers (24.4% vs. 14.4%, P < 0.001). Persons with primary school education or less were 1.89 times (P = 0.03) more likely to have undercorrected refractive errors than those with post-secondary school education or higher. In contrast, persons with a history of eye disease were 0.74 times (P = 0.003) less likely to have undercorrected refractive errors. The proportion of undercorrected refractive error among the Singaporean Malay adults with refractive errors was higher than that of the Singaporean Chinese adults with refractive errors. Undercorrected refractive error is a significant cause of correctable visual impairment among Singaporean Malay adults, affecting one in five persons.

  19. Atmospheric microwave refractivity and refraction

    NASA Technical Reports Server (NTRS)

    Yu, E.; Hodge, D. B.

    1980-01-01

    The atmospheric refractivity can be expressed as a function of temperature, pressure, water vapor content, and operating frequency. Based on twenty-year meteorological data, statistics of the atmospheric refractivity were obtained. These statistics were used to estimate the variation of dispersion, attenuation, and refraction effects on microwave and millimeter wave signals propagating along atmospheric paths. Bending angle, elevation angle error, and range error were also developed for an exponentially tapered, spherical atmosphere.

  20. Plasmon-negative refraction at the heterointerface of graphene sheet arrays.

    PubMed

    Huang, He; Wang, Bing; Long, Hua; Wang, Kai; Lu, Peixiang

    2014-10-15

    We demonstrate negative refraction of surface plasmon polaritons (SPPs) at the heterointerface of two monolayer graphene sheet arrays (MGSAs) with different periods. The refraction angle is specifically related to the period ratio of the two MGSAs. By varying the incident Bloch momentum, the SPPs might be refracted in the direction normal to the heterointerface. Moreover, both positive and negative refraction could appear simultaneously. Because of the linear diffraction relation, the incident and refracted SPP beams experience diffraction-free propagation. The heterostructures composed of the MGSAs may find great applications in deep-subwavelength spatial light modulators, optical splitters, and switches.

  1. Generalized ray tracing method for the calculation of the peripheral refraction induced by an ophthalmic lens

    NASA Astrophysics Data System (ADS)

    Rojo, Pilar; Royo, Santiago; Caum, Jesus; Ramírez, Jorge; Madariaga, Ines

    2015-02-01

    Peripheral refraction, the refractive error present outside the main direction of gaze, has lately attracted interest due to its alleged relationship with the progression of myopia. The ray tracing procedures involved in its calculation need to follow an approach different from those used in conventional ophthalmic lens design, where refractive errors are compensated only in the main direction of gaze. We present a methodology for the evaluation of the peripheral refractive error in ophthalmic lenses, adapting the conventional generalized ray tracing approach to the requirements of the evaluation of peripheral refraction. The nodal point of the eye and a retinal conjugate surface will be used to evaluate the three-dimensional distribution of refractive error around the fovea. The proposed approach enables us to calculate the three-dimensional peripheral refraction induced by any ophthalmic lens at any direction of gaze and to personalize the lens design to the requirements of the user. The complete evaluation process for a given user prescribed with a -5.76D ophthalmic lens for foveal vision is detailed, and comparative results obtained when the geometry of the lens is modified and when the central refractive error is over- or undercorrected. The methodology is also applied for an emmetropic eye to show its application for refractive errors other than myopia.

  2. Patterns in longitudinal growth of refraction in Southern Chinese children: cluster and principal component analysis.

    PubMed

    Chen, Yanxian; Chang, Billy Heung Wing; Ding, Xiaohu; He, Mingguang

    2016-11-22

    In the present study we attempt to use hypothesis-independent analysis in investigating the patterns in refraction growth in Chinese children, and to explore the possible risk factors affecting the different components of progression, as defined by Principal Component Analysis (PCA). A total of 637 first-born twins in Guangzhou Twin Eye Study with 6-year annual visits (baseline age 7-15 years) were available in the analysis. Cluster 1 to 3 were classified after a partitioning clustering, representing stable, slow and fast progressing groups of refraction respectively. Baseline age and refraction, paternal refraction, maternal refraction and proportion of two myopic parents showed significant differences across the three groups. Three major components of progression were extracted using PCA: "Average refraction", "Acceleration" and the combination of "Myopia stabilization" and "Late onset of refraction progress". In regression models, younger children with more severe myopia were associated with larger "Acceleration". The risk factors of "Acceleration" included change of height and weight, near work, and parental myopia, while female gender, change of height and weight were associated with "Stabilization", and increased outdoor time was related to "Late onset of refraction progress". We therefore concluded that genetic and environmental risk factors have different impacts on patterns of refraction progression.

  3. Autorefraction Versus Manifest Refraction in Patients With Keratoconus.

    PubMed

    Soeters, Nienke; Muijzer, Marc B; Molenaar, Jurrian; Godefrooij, Daniel A; Wisse, Robert P L

    2018-01-01

    To compare visual performance using autorefraction and manifest refraction assessments in patients with keratoconus and investigate whether autorefraction measurements lead to suboptimal visual performance. Corrected distance visual acuity (CDVA) was measured in 90 eyes of 61 patients with keratoconus with both autorefraction and manifest refraction, in a random order. Maximum keratometry (Kmax), cone location, and wavefront aberration were determined with Scheimpflug tomography. The difference between the autorefraction and manifest refraction outcomes was converted to vectors and a multivariable analysis was performed to identify potential underlying causes of this difference. A significantly better CDVA was achieved with manifest refraction (0.06 vs 0.29 logMAR [20/23 vs 20/38 Snellen], P < .001). After vector analysis, a mean difference of 4.83 diopters was found between autorefraction and manifest refraction. Increased Kmax was strongly and significantly associated with better visual performance of manifest refraction compared to autorefraction (B = 0.496, P = .002). This study showed that a superior CDVA is achieved with manifest refraction compared to autorefraction in patients with keratoconus. Furthermore, the difference between the two refraction methods increases as the cornea steepens. According to this study, autorefraction is unreliable in patients with keratoconus and should be avoided. [J Refract Surg. 2018;34(1):30-34.]. Copyright 2018, SLACK Incorporated.

  4. Regional variation in the refractive-index of the bovine and human cornea.

    PubMed

    Vasudevan, Balamurali; Simpson, Trefford L; Sivak, Jacob G

    2008-10-01

    Given the refractive importance of the human cornea, surprisingly little attention has been directed to the study of local variation in corneal refractive-index. This in vitro and in vivo study measures the refractive-index of different portions of the bovine and human cornea. Fifty fresh bovine corneas (obtained from an abattoir) and 10 human subjects were used for the study. The refractive-index of the central, nasal, and temporal corneal epithelium was measured with a bench-top Abbe refractometer in the case of bovine corneas and with a hand-held refractometer with humans. The mean (+/-standard deviation) refractive-indices of the central, nasal, and temporal bovine corneal epithelium were 1.3760 (+/-0.003), 1.3757 (+/-0.002), and 1.3746 (+/-0.002), respectively. Refractive-indices of the anterior and posterior bovine corneal stroma were 1.3731 (+/-0.002) and 1.3708 (+/-0.004), respectively. The mean (+/-standard deviation) refractive-index in the central, nasal, and temporal periphery of the human cornea epithelium were 1.3970 (+/-0.001), 1.3946 (+/-0.001), and 1.3940 (+/-0.001), respectively. There are small local differences in the refractive-index of the bovine and human corneal epithelium and the refractive-index of the epithelium is higher than that of the anterior and posterior stroma of the bovine cornea.

  5. Influence of posterior corneal astigmatism on postoperative refractive astigmatism in pseudophakic eyes after cataract surgery.

    PubMed

    Sano, Maki; Hiraoka, Takahiro; Ueno, Yuta; Itagaki, Hideo; Ogami, Tomohiro; Oshika, Tetsuro

    2016-12-01

    To examine the influence of posterior corneal astigmatism on postoperative refractive astigmatism in pseudophakic eyes after cataract surgery. The study enrolled 64 pseudophakic eyes of 50 patients (71.8 ± 9.9 years old, mean ± standard deviation) who had undergone phacoemulsification with non-toric IOL implantation. Refractive astigmatism was measured using an auto ref-keratometer with a 0.01- diopter (D) scale. Two types of corneal astigmatism were calculated using anterior segment optical coherence tomography; keratometric and total corneal astigmatism. Keratometric astigmatism was obtained based on anterior corneal curvature alone and total corneal astigmatism was calculated using both anterior and posterior corneal curvatures. The difference between refractive and corneal astigmatism was computed as the vector difference using 1) refractive and keratometric astigmatism and 2) refractive and total corneal astigmatism. The mean refractive, keratometric, and total corneal astigmatism was 0.92 ± 0.48 D, 0.87 ± 0.44 D, and 0.94 ± 0.46 D, respectively. The difference between refractive and keratometric astigmatism (0.70 ± 0.40 D, mean vector of 0.30 D axis 164°) was significantly larger than the difference between refractive and total corneal astigmatism (0.63 ± 0.38 D, mean vector of 0.12 D axis 137°) (P = .019). The difference between refractive and total corneal astigmatism, calculated using both anterior and posterior corneal curvatures, was significantly smaller than the difference between refractive and keratometric astigmatism using anterior corneal astigmatism alone, implying that the latter overestimates the true postoperative refractive astigmatism and can cause cylindrical inaccuracy after cataract surgery.

  6. Change in peripheral refraction and curvature of field of the human eye with accommodation

    NASA Astrophysics Data System (ADS)

    Ho, Arthur; Zimmermann, Frederik; Whatham, Andrew; Martinez, Aldo; Delgado, Stephanie; Lazon de la Jara, Percy; Sankaridurg, Padmaja

    2009-02-01

    Recent research showed that the peripheral refractive state is a sufficient stimulus for myopia progression. This finding led to the suggestion that devices that control peripheral refraction may be efficacious in controlling myopia progression. This study aims to understand whether the optical effect of such devices may be affected by near focus. In particular, we seek to understand the influence of accommodation on peripheral refraction and curvature of field of the eye. Refraction was measured in twenty young subjects using an autorefractor at 0° (i.e. along visual axis), and 20°, 30° and 40° field angles both nasal and temporal to the visual axis. All measurements were conducted at 2.5 m, 40 cm and 30 cm viewing distances. Refractive errors were corrected using a soft contact lens during all measurements. As field angle increased, refraction became less hyperopic. Peripheral refraction also became less hyperopic at nearer viewing distances (i.e. with increasing accommodation). Astigmatism (J180) increased with field angle as well as with accommodation. Adopting a third-order aberration theory approach, the position of the Petzval surface relative to the retinal surface was estimated by considering the relative peripheral refractive error (RPRE) and J180 terms of peripheral refraction. Results for the estimated dioptric position of the Petzval surface relative to the retina showed substantial asymmetry. While temporal field tended to agree with theoretical predictions, nasal response departed dramatically from the model eye predictions. With increasing accommodation, peripheral refraction becomes less hyperopic while the Petzval surface showed asymmetry in its change in position. The change in the optical components (i.e. cornea and/or lens as opposed to retinal shape or position) is implicated as at least one of the contributors of this shift in peripheral refraction during accommodation.

  7. Refractive power and biometric properties of the nonhuman primate isolated crystalline lens.

    PubMed

    Borja, David; Manns, Fabrice; Ho, Arthur; Ziebarth, Noel M; Acosta, Ana Carolina; Arrieta-Quintera, Esdras; Augusteyn, Robert C; Parel, Jean-Marie

    2010-04-01

    Purpose. To characterize the age dependence of shape, refractive power, and refractive index of isolated lenses from nonhuman primates. Methods. Measurements were performed on ex vivo lenses from cynomolgus monkeys (cyno: n = 120; age, 2.7-14.3 years), rhesus monkeys (n = 61; age, 0.7-13.3 years), and hamadryas baboons (baboon: n = 16; age, 1.7-27.3 years). Lens thickness, diameter, and surface curvatures were measured with an optical comparator. Lens refractive power was measured with a custom optical system based on the Scheiner principle. The refractive contributions of the gradient, the surfaces, and the equivalent refractive index were calculated with optical ray-tracing software. The age dependence of the optical and biometric parameters was assessed. Results. Over the measured age range isolated lens thickness decreased (baboon: -0.04, cyno: -0.05, and rhesus: -0.06 mm/y) and equatorial diameter increased (logarithmically for the baboon and rhesus, and linearly for cyno: 0.07 mm/y). The isolated lens surfaces flattened and the corresponding refractive power from the surfaces decreased with age (-0.33, -0.48, and -0.68 D/y). The isolated lens equivalent refractive index decreased (only significant for the baboon, -0.001 D/y), and as a result the total isolated lens refractive power decreased with age (baboon: -1.26, cyno: -0.97, and rhesus: -1.76 D/y). Conclusions. The age-dependent trends in the optical and biometric properties, growth, and aging, of nonhuman primate lenses are similar to those of the pre-presbyopic human lens. As the lens ages, the decrease in refractive contributions from the gradient refractive index causes a rapid age-dependent decrease in maximally accommodated lens refractive power.

  8. Profile of refractive errors in cerebral palsy: impact of severity of motor impairment (GMFCS) and CP subtype on refractive outcome.

    PubMed

    Saunders, Kathryn J; Little, Julie-Anne; McClelland, Julie F; Jackson, A Jonathan

    2010-06-01

    To describe refractive status in children and young adults with cerebral palsy (CP) and relate refractive error to standardized measures of type and severity of CP impairment and to ocular dimensions. A population-based sample of 118 participants aged 4 to 23 years with CP (mean 11.64 +/- 4.06) and an age-appropriate control group (n = 128; age, 4-16 years; mean, 9.33 +/- 3.52) were recruited. Motor impairment was described with the Gross Motor Function Classification Scale (GMFCS), and subtype was allocated with the Surveillance of Cerebral Palsy in Europe (SCPE). Measures of refractive error were obtained from all participants and ocular biometry from a subgroup with CP. A significantly higher prevalence and magnitude of refractive error was found in the CP group compared to the control group. Axial length and spherical refractive error were strongly related. This relation did not improve with inclusion of corneal data. There was no relation between the presence or magnitude of spherical refractive errors in CP and the level of motor impairment, intellectual impairment, or the presence of communication difficulties. Higher spherical refractive errors were significantly associated with the nonspastic CP subtype. The presence and magnitude of astigmatism were greater when intellectual impairment was more severe, and astigmatic errors were explained by corneal dimensions. Conclusions. High refractive errors are common in CP, pointing to impairment of the emmetropization process. Biometric data support this In contrast to other functional vision measures, spherical refractive error is unrelated to CP severity, but those with nonspastic CP tend to demonstrate the most extreme errors in refraction.

  9. Determination of the refractive index of microparticles by utilizing light dispersion properties of the particle and an immersion liquid.

    PubMed

    Niskanen, I; Räty, J; Peiponen, K E

    2013-10-15

    The knowledge of the refractive index of a particle is important in sensing and imaging applications, e.g., in biology, medicine and process industry. The refractive index of tiny solid particles such as microsize particles can be determined by the so-called liquid immersion technique. This study deals with three different types of interrogation methods to get the refractive index of a particle in a liquid matrix. These methods utilize thermo-optical properties and wavelength-dependent refractive index of the particle and the immersion liquids, as well as, the classical method using a set of in advance prepared set of immersion liquids with different refractive indices. The emphasis is on a method to get especially the wavelength-dependent refractive index of microparticles and exploiting different wavelength-dependences of immersion liquid and a solid particle because identification of a particle is more reliable if the refractive index of the particle is known at several wavelengths. In this study glycerol-water mixtures served as immersion liquids to obtain the refractive index of CaF2 at several discrete wavelengths in the spectral range 200-500 nm. The idea is to find the maximum value of light transmission of suspension by scanning the wavelength of a commercial spectrophotometer. The light dispersion-based method is suggested as a relatively easy, economic and fast method to determine the refractive index of a particle by a spectrophotometer at several wavelengths of light. The accuracy of the detection of the refractive index is suggested to be better than ± 0.005 refractive index units. © 2013 Elsevier B.V. All rights reserved.

  10. Measurement of refractive index profile of non-symmetric, complex silica preforms with high refractive index differences

    NASA Astrophysics Data System (ADS)

    Probostova, Jana; Slanicka, Jiri; Mrazek, Jan; Podrazky, Ondrej; Benda, Adam; Peterka, Pavel

    2016-04-01

    Refractive index profile measurement is a key instrument for characterization of optical properties of preforms, which are used for drawing of high-quality optical fibers. Common industrial optical preform analyzers have been designed for measurement of simple symmetric structures such as step-index or graded-index preforms with refractive index close to the silica (n=1.457 at 633 nm). However, these conditions are usually far from more complex structures used in fiber lasers or in fiber sensor area. Preforms for the drawing of advanced optical fibers, such as Bragg, microstructure or photonic crystal fibers, are usually constituted from stacks with non-symmetric internal structure or composed of alternating layers with high refractive index contrasts. In this paper we present comparison of refractive index profile measurements of simple as well as complex structures with high refractive index differences simulating the Bragg structures. Commercial Photon Kinetics 2600 preform analyzer was used for the refractive index profile measurements. A set of concentrically arranged silica tubes was welded to form a complex preforms. Free space between the tubes was filled by immersion with varying refractive indices to simulate the Bragg structure. Up to three tubes were used for the analysis and the refractive indices of immersion were changed from 1.4 to 1.5. When refractive index of immersion was independently measured the structure of preform was defined. Profiles of these "known" structures were compared to measured data processed by originally proposed algorithm. The work provides an extension of issues of refractive index profile measurements in non-symmetric complex silica structures by a commercial preform analyzer and proposes more convenient methods of numeric data processing.

  11. Refraction near the horizon

    NASA Technical Reports Server (NTRS)

    Schaefer, Bradley E.; Liller, William

    1990-01-01

    Variations in astronomical refraction near the horizon are examined. Sunset timings, a sextant mounted on a tripod, and a temperature profile are utilized to derive the variations in refraction data, collected from 7 locations. It is determined that the refraction ranges from 0.234 to 1.678 deg with an rms deviation of 0.16, and it is observed that the variation is larger than previously supposed. Some applications for the variation of refraction value are discussed.

  12. Linkage Analysis of Quantitative Refraction and Refractive Errors in the Beaver Dam Eye Study

    PubMed Central

    Duggal, Priya; Lee, Kristine E.; Cheng, Ching-Yu; Klein, Ronald; Bailey-Wilson, Joan E.; Klein, Barbara E. K.

    2011-01-01

    Purpose. Refraction, as measured by spherical equivalent, is the need for an external lens to focus images on the retina. While genetic factors play an important role in the development of refractive errors, few susceptibility genes have been identified. However, several regions of linkage have been reported for myopia (2q, 4q, 7q, 12q, 17q, 18p, 22q, and Xq) and for quantitative refraction (1p, 3q, 4q, 7p, 8p, and 11p). To replicate previously identified linkage peaks and to identify novel loci that influence quantitative refraction and refractive errors, linkage analysis of spherical equivalent, myopia, and hyperopia in the Beaver Dam Eye Study was performed. Methods. Nonparametric, sibling-pair, genome-wide linkage analyses of refraction (spherical equivalent adjusted for age, education, and nuclear sclerosis), myopia and hyperopia in 834 sibling pairs within 486 extended pedigrees were performed. Results. Suggestive evidence of linkage was found for hyperopia on chromosome 3, region q26 (empiric P = 5.34 × 10−4), a region that had shown significant genome-wide evidence of linkage to refraction and some evidence of linkage to hyperopia. In addition, the analysis replicated previously reported genome-wide significant linkages to 22q11 of adjusted refraction and myopia (empiric P = 4.43 × 10−3 and 1.48 × 10−3, respectively) and to 7p15 of refraction (empiric P = 9.43 × 10−4). Evidence was also found of linkage to refraction on 7q36 (empiric P = 2.32 × 10−3), a region previously linked to high myopia. Conclusions. The findings provide further evidence that genes controlling refractive errors are located on 3q26, 7p15, 7p36, and 22q11. PMID:21571680

  13. Impact of Primary Spherical Aberration, Spatial Frequency and Stiles Crawford Apodization on Wavefront determined Refractive Error: A Computational Study

    PubMed Central

    Xu, Renfeng; Bradley, Arthur; Thibos, Larry N.

    2013-01-01

    Purpose We tested the hypothesis that pupil apodization is the basis for central pupil bias of spherical refractions in eyes with spherical aberration. Methods We employed Fourier computational optics in which we vary spherical aberration levels, pupil size, and pupil apodization (Stiles Crawford Effect) within the pupil function, from which point spread functions and optical transfer functions were computed. Through-focus analysis determined the refractive correction that optimized retinal image quality. Results For a large pupil (7 mm), as spherical aberration levels increase, refractions that optimize the visual Strehl ratio mirror refractions that maximize high spatial frequency modulation in the image and both focus a near paraxial region of the pupil. These refractions are not affected by Stiles Crawford Effect apodization. Refractions that optimize low spatial frequency modulation come close to minimizing wavefront RMS, and vary with level of spherical aberration and Stiles Crawford Effect. In the presence of significant levels of spherical aberration (e.g. C40 = 0.4 µm, 7mm pupil), low spatial frequency refractions can induce −0.7D myopic shift compared to high SF refraction, and refractions that maximize image contrast of a 3 cycle per degree square-wave grating can cause −0.75D myopic drift relative to refractions that maximize image sharpness. Discussion Because of small depth of focus associated with high spatial frequency stimuli, the large change in dioptric power across the pupil caused by spherical aberration limits the effective aperture contributing to the image of high spatial frequencies. Thus, when imaging high spatial frequencies, spherical aberration effectively induces an annular aperture defining that portion of the pupil contributing to a well-focused image. As spherical focus is manipulated during the refraction procedure, the dimensions of the annular aperture change. Image quality is maximized when the inner radius of the induced annulus falls to zero, thus defining a circular near paraxial region of the pupil that determines refraction outcome. PMID:23683093

  14. Topography-modified refraction (TMR): adjustment of treated cylinder amount and axis to the topography versus standard clinical refraction in myopic topography-guided LASIK.

    PubMed

    Kanellopoulos, Anastasios John

    2016-01-01

    To evaluate the safety, efficacy, and contralateral eye comparison of topography-guided myopic LASIK with two different refraction treatment strategies. Private clinical ophthalmology practice. A total of 100 eyes (50 patients) in consecutive cases of myopic topography-guided LASIK procedures with the same refractive platform (FS200 femtosecond and EX500 excimer lasers) were randomized for treatment as follows: one eye with the standard clinical refraction (group A) and the contralateral eye with the topographic astigmatic power and axis (topography-modified treatment refraction; group B). All cases were evaluated pre- and post-operatively for the following parameters: refractive error, best corrected distance visual acuity (CDVA), uncorrected distance visual acuity (UDVA), topography (Placido-disk based) and tomography (Scheimpflug-image based), wavefront analysis, pupillometry, and contrast sensitivity. Follow-up visits were conducted for at least 12 months. Mean refractive error was -5.5 D of myopia and -1.75 D of astigmatism. In group A versus group B, respectively, the average UDVA improved from 20/200 to 20/20 versus 20/16; post-operative CDVA was 20/20 and 20/13.5; 1 line of vision gained was 27.8% and 55.6%; and 2 lines of vision gained was 5.6% and 11.1%. In group A, 27.8% of eyes had over -0.50 diopters of residual refractive astigmatism, in comparison to 11.7% in group B ( P <0.01). The residual percentages in both groups were measured with refractive astigmatism of more than -0.5 diopters. Topography-modified refraction (TMR): topographic adjustment of the amount and axis of astigmatism treated, when different from the clinical refraction, may offer superior outcomes in topography-guided myopic LASIK. These findings may change the current clinical paradigm of the optimal subjective refraction utilized in laser vision correction.

  15. Topography-modified refraction (TMR): adjustment of treated cylinder amount and axis to the topography versus standard clinical refraction in myopic topography-guided LASIK

    PubMed Central

    Kanellopoulos, Anastasios John

    2016-01-01

    Purpose To evaluate the safety, efficacy, and contralateral eye comparison of topography-guided myopic LASIK with two different refraction treatment strategies. Setting Private clinical ophthalmology practice. Patients and methods A total of 100 eyes (50 patients) in consecutive cases of myopic topography-guided LASIK procedures with the same refractive platform (FS200 femtosecond and EX500 excimer lasers) were randomized for treatment as follows: one eye with the standard clinical refraction (group A) and the contralateral eye with the topographic astigmatic power and axis (topography-modified treatment refraction; group B). All cases were evaluated pre- and post-operatively for the following parameters: refractive error, best corrected distance visual acuity (CDVA), uncorrected distance visual acuity (UDVA), topography (Placido-disk based) and tomography (Scheimpflug-image based), wavefront analysis, pupillometry, and contrast sensitivity. Follow-up visits were conducted for at least 12 months. Results Mean refractive error was −5.5 D of myopia and −1.75 D of astigmatism. In group A versus group B, respectively, the average UDVA improved from 20/200 to 20/20 versus 20/16; post-operative CDVA was 20/20 and 20/13.5; 1 line of vision gained was 27.8% and 55.6%; and 2 lines of vision gained was 5.6% and 11.1%. In group A, 27.8% of eyes had over −0.50 diopters of residual refractive astigmatism, in comparison to 11.7% in group B (P<0.01). The residual percentages in both groups were measured with refractive astigmatism of more than −0.5 diopters. Conclusion Topography-modified refraction (TMR): topographic adjustment of the amount and axis of astigmatism treated, when different from the clinical refraction, may offer superior outcomes in topography-guided myopic LASIK. These findings may change the current clinical paradigm of the optimal subjective refraction utilized in laser vision correction. PMID:27843292

  16. Virtual and super - virtual refraction method: Application to synthetic data and 2012 of Karangsambung survey data

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nugraha, Andri Dian; Adisatrio, Philipus Ronnie

    2013-09-09

    Seismic refraction survey is one of geophysical method useful for imaging earth interior, definitely for imaging near surface. One of the common problems in seismic refraction survey is weak amplitude due to attenuations at far offset. This phenomenon will make it difficult to pick first refraction arrival, hence make it challenging to produce the near surface image. Seismic interferometry is a new technique to manipulate seismic trace for obtaining Green's function from a pair of receiver. One of its uses is for improving first refraction arrival quality at far offset. This research shows that we could estimate physical properties suchmore » as seismic velocity and thickness from virtual refraction processing. Also, virtual refraction could enhance the far offset signal amplitude since there is stacking procedure involved in it. Our results show super - virtual refraction processing produces seismic image which has higher signal-to-noise ratio than its raw seismic image. In the end, the numbers of reliable first arrival picks are also increased.« less

  17. Refractive Errors Affect the Vividness of Visual Mental Images

    PubMed Central

    Palermo, Liana; Nori, Raffaella; Piccardi, Laura; Zeri, Fabrizio; Babino, Antonio; Giusberti, Fiorella; Guariglia, Cecilia

    2013-01-01

    The hypothesis that visual perception and mental imagery are equivalent has never been explored in individuals with vision defects not preventing the visual perception of the world, such as refractive errors. Refractive error (i.e., myopia, hyperopia or astigmatism) is a condition where the refracting system of the eye fails to focus objects sharply on the retina. As a consequence refractive errors cause blurred vision. We subdivided 84 individuals according to their spherical equivalent refraction into Emmetropes (control individuals without refractive errors) and Ametropes (individuals with refractive errors). Participants performed a vividness task and completed a questionnaire that explored their cognitive style of thinking before their vision was checked by an ophthalmologist. Although results showed that Ametropes had less vivid mental images than Emmetropes this did not affect the development of their cognitive style of thinking; in fact, Ametropes were able to use both verbal and visual strategies to acquire and retrieve information. Present data are consistent with the hypothesis of equivalence between imagery and perception. PMID:23755186

  18. Understanding refraction contrast using a comparison of absorption and refraction computed tomographic techniques

    NASA Astrophysics Data System (ADS)

    Wiebe, S.; Rhoades, G.; Wei, Z.; Rosenberg, A.; Belev, G.; Chapman, D.

    2013-05-01

    Refraction x-ray contrast is an imaging modality used primarily in a research setting at synchrotron facilities, which have a biomedical imaging research program. The most common method for exploiting refraction contrast is by using a technique called Diffraction Enhanced Imaging (DEI). The DEI apparatus allows the detection of refraction between two materials and produces a unique ''edge enhanced'' contrast appearance, very different from the traditional absorption x-ray imaging used in clinical radiology. In this paper we aim to explain the features of x-ray refraction contrast as a typical clinical radiologist would understand. Then a discussion regarding what needs to be considered in the interpretation of the refraction image takes place. Finally we present a discussion about the limitations of planar refraction imaging and the potential of DEI Computed Tomography. This is an original work that has not been submitted to any other source for publication. The authors have no commercial interests or conflicts of interest to disclose.

  19. Refractive index measurements in absorbing media with white light spectral interferometry.

    PubMed

    Arosa, Yago; Lago, Elena López; de la Fuente, Raúl

    2018-03-19

    White light spectral interferometry is applied to measure the refractive index in absorbing liquids in the spectral range of 400-1000 nm. We analyze the influence of absorption on the visibility of interferometric fringes and, accordingly, on the measurement of the refractive index. Further, we show that the refractive index in the absorption band can be retrieved by a two-step process. The procedure requires the use of two samples of different thickness, the thicker one to retrieve the refractive index in the transparent region and the thinnest to obtain the data in the absorption region. First, the refractive index values are retrieved with good accuracy in the transparent region of the material for 1-mm-thick samples. Second, these refractive index values serve also to precisely calculate the thickness of a thinner sample (~150 µm) since the accuracy of the methods depends strongly on the thickness of the sample. Finally, the refractive index is recovered for the entire spectral range.

  20. Refractive errors affect the vividness of visual mental images.

    PubMed

    Palermo, Liana; Nori, Raffaella; Piccardi, Laura; Zeri, Fabrizio; Babino, Antonio; Giusberti, Fiorella; Guariglia, Cecilia

    2013-01-01

    The hypothesis that visual perception and mental imagery are equivalent has never been explored in individuals with vision defects not preventing the visual perception of the world, such as refractive errors. Refractive error (i.e., myopia, hyperopia or astigmatism) is a condition where the refracting system of the eye fails to focus objects sharply on the retina. As a consequence refractive errors cause blurred vision. We subdivided 84 individuals according to their spherical equivalent refraction into Emmetropes (control individuals without refractive errors) and Ametropes (individuals with refractive errors). Participants performed a vividness task and completed a questionnaire that explored their cognitive style of thinking before their vision was checked by an ophthalmologist. Although results showed that Ametropes had less vivid mental images than Emmetropes this did not affect the development of their cognitive style of thinking; in fact, Ametropes were able to use both verbal and visual strategies to acquire and retrieve information. Present data are consistent with the hypothesis of equivalence between imagery and perception.

  1. Refractive index, molar refraction and comparative refractive index study of propylene carbonate binary liquid mixtures.

    PubMed

    Wankhede, Dnyaneshwar Shamrao

    2012-06-01

    Refractive indices (n) have been experimentally determined for the binary liquid-liquid mixtures of Propylene carbonate (PC) (1) with benzene, ethylbenzene, o-xylene and p-xylene (2) at 298.15, 303.15 and 308.15 K over the entire mole fraction range. The experimental values of n are utilised to calculate deviation in refractive index (Δn), molar refraction (R) and deviation in molar refraction (ΔR). A comparative study of Arago-Biot (A-B), Newton (NW), Eyring and John (E-J) equations for determining refractive index of a liquid has been carried out to test their validity for all the binary mixtures over the entire composition range at 298.15 K. Comparison of various mixing relations is represented in terms of average deviation (AVD). The Δn and ΔR values have been fitted to Redlich-Kister equation at 298.15 K and standard deviations have been calculated. The results are discussed in terms of intermolecular interactions present amongst the components.

  2. Accuracy of refractive outcomes in myopic and hyperopic laser in situ keratomileusis: Manifest versus aberrometric refraction.

    PubMed

    Reinstein, Dan Z; Morral, Merce; Gobbe, Marine; Archer, Timothy J

    2012-11-01

    To compare the achieved refractive accuracy of laser in situ keratomileusis (LASIK) performed based on manifest refraction with the predicted accuracy that would have been achieved using WASCA aberrometric refraction with and without Seidel correction factor for sphere. London Vision Clinic, London, United Kingdom. Comparative case series. Myopic eyes and hyperopic eyes had LASIK based on manifest refraction. Two aberrometric refractions were obtained preoperatively: Seidel, which includes spherical aberration in the sphere calculation, and non-Seidel. Bland-Altman plots were used to show the agreement between aberrometric and manifest refractions. Predicted LASIK outcomes had aberrometric refraction been used were modeled by shifting the postoperative manifest refraction by the vector difference between the preoperative manifest and aberrometric refractions. This study included 869 myopic eyes and 413 hyperopic eyes. The mean differences (manifest minus aberrometric) in spherical equivalent were +0.03 diopters (D) ± 0.48 (SD) (Seidel aberrometric) and +0.45 ± 0.42 D (non-Seidel aberrometric) for myopia and -0.20 ± 0.39 D and +0.39 ± 0.34 D, respectively, for hyperopia. The mean differences in cylinder magnitude were -0.10 ± 0.27 D and 0.00 ± 0.25 D, respectively. The percentage of eyes within ±0.50 D of the attempted correction was 81% (manifest), 70% (Seidel), and 67% (non-Seidel) for myopia and 71% (manifest), 61% (Seidel), and 64% (non-Seidel) for hyperopia. The achieved refractive accuracy by manifest refraction was better than the predicted accuracy had Seidel or non-Seidel aberrometric refractions been used for surgical planning. Using the Seidel method improved the accuracy in myopic eyes but not in hyperopic eyes. Dr. Reinstein is a consultant to Carl Zeiss Meditec AG and has a proprietary interest in the Artemis technology (Arcscan Inc., Morrison, Colorado, USA) through patents administered by the Cornell Center for Technology Enterprise and Commercialization, Ithaca, New York. No other author has a financial or proprietary interest in any material or method mentioned. Copyright © 2012 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  3. Time course of the effects of orthokeratology on peripheral refraction and corneal topography.

    PubMed

    Kang, Pauline; Swarbrick, Helen

    2013-05-01

    To describe the time course of changes in both peripheral refraction and corneal topography in myopic adults wearing myopic orthokeratology (OK) lenses. Nineteen adult myopes were fitted with OK lenses in both eyes for overnight wear. Central and peripheral refraction and corneal topography were measured along the horizontal meridian at baseline and after 1, 4, 7 and 14 nights of lens wear. At baseline, refraction was myopic at all positions along the horizontal meridian. Two weeks of OK lens wear caused a significant change in refraction where the general trend was a hyperopic shift in spherical equivalent (M) except at 35° in the nasal visual field where there was instead a myopic shift in M. The most significant change in M occurred between baseline and after 1 night of OK lens wear and the effect became less dramatic across subsequent days of OK treatment. Similarly, OK caused significant change in corneal refractive power at all positions along the horizontal corneal chord. There was a reduction in corneal power or flattening of the cornea at all positions except at 2.4 mm and 2.8 mm on the nasal cornea where there was an increase in corneal refractive power or steepening of the cornea. This change was most apparent after 1 night of OK lens wear and, similar to changes in peripheral refraction, changes in corneal refractive power on subsequent days of OK treatment became less marked. Orthokeratology caused significant changes in both peripheral refraction and corneal topography. The greatest change in refraction and corneal refractive power across the horizontal corneal meridian occurred during the first night of OK lens wear. Subsequent changes in both peripheral refraction and corneal topography were less dramatic, in the same manner as reported changes in apical radius and central refraction after OK. This study confirms that with OK treatment, the peripheral retina experiences myopic defocus, which is conjectured to underlie the observed slowing of myopia progression. Ophthalmic & Physiological Optics © 2013 The College of Optometrists.

  4. Refraction effects of atmosphere on geodetic measurements to celestial bodies

    NASA Technical Reports Server (NTRS)

    Joshi, C. S.

    1973-01-01

    The problem is considered of obtaining accurate values of refraction corrections for geodetic measurements of celestial bodies. The basic principles of optics governing the phenomenon of refraction are defined, and differential equations are derived for the refraction corrections. The corrections fall into two main categories: (1) refraction effects due to change in the direction of propagation, and (2) refraction effects mainly due to change in the velocity of propagation. The various assumptions made by earlier investigators are reviewed along with the basic principles of improved models designed by investigators of the twentieth century. The accuracy problem for various quantities is discussed, and the conclusions and recommendations are summarized.

  5. Angularly symmetric splitting of a light beam upon reflection and refraction at an air-dielectric plane boundary: comment.

    PubMed

    Andersen, Torben B

    2016-05-01

    In a recent paper, conditions for achieving equal and opposite angular deflections of a light beam by reflection and refraction at an interface between air and a dielectric were determined [J. Opt. Soc. Am. A32, 2436 (2015)JOAOD60740-323210.1364/JOSAA.32.002436]. The paper gives plots of angles of incidence and refraction as a function of the prism refractive index as well as plots of reflectances and incident linear-polarization azimuth angles as functions of the refractive index. We show here that it is possible to express these quantities as simple algebraic functions of the refractive index.

  6. Achieving target refraction after cataract surgery.

    PubMed

    Simon, Shira S; Chee, Yewlin E; Haddadin, Ramez I; Veldman, Peter B; Borboli-Gerogiannis, Sheila; Brauner, Stacey C; Chang, Kenneth K; Chen, Sherleen H; Gardiner, Matthew F; Greenstein, Scott H; Kloek, Carolyn E; Chen, Teresa C

    2014-02-01

    To evaluate the difference between target and actual refraction after phacoemulsification and intraocular lens implantation at an academic teaching institution's Comprehensive Ophthalmology Service. Retrospective study. We examined 1275 eye surgeries for this study. All consecutive cataract surgeries were included if they were performed by an attending or resident surgeon from January through December 2010. Postoperative refractions were compared with preoperative target refractions. Patients were excluded if they did not have a preoperative target refraction documented or if they did not have a recorded postoperative manifest refraction within 90 days. The main outcome measure was percentage of cases achieving a postoperative spherical equivalent ± 1.0 diopter (D) of target spherical equivalent. We performed 1368 cataract surgeries from January through December of 2010. Of these, 1275 (93%) had sufficient information for analysis. Of the included cases, 94% (1196 of 1275) achieved ± 1.0 D of target refraction by 90 days after cataract surgery. This paper establishes a new benchmark for a teaching hospital, where 94% of patients achieved within 1.0 D of target refraction after cataract surgery. The refractive outcomes after cataract surgery at this academic teaching institution were higher than average international benchmarks. Copyright © 2014 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  7. REFRACTOMETRY AS A TOOL IN DIABETIC STUDIES

    PubMed Central

    Kavitha, S.; Murthy, V.R.

    2006-01-01

    The refractive index as well as molar refraction, is the true index of purity of substance and plays a vital role in solution chemistry. A small addition of a foreign substance either in solid state of liquid form is going to effect the refractive index. As such the variation of refractive indices in pure glucose solution as a function of concentration is studied in detail and this principle is extended to the study of the refractive indices of urine solution of diabetic patients. The refractive indices are measured by spectrometry and abbe refractometry. A detailed study of variation of refractive indices of urine samples containing different sugar concentrations, of patients of different age groups revealed that the increase in refractive index follows a linear scale and can be explained by the equation, n=no [l+0.00251og (a s)1/4] [l+0.031og0.011C]. These study provided an opportunity to project refractometry as an effective tool in diagnosing the diabetic level of a patient by making use of a simple calibration curve of increment in refractive index ‘Δn, as a function of level of the disease. PMID:22557211

  8. Application of refractometry to quality assurance monitoring of parenteral nutrition solutions.

    PubMed

    Chang, Wei-Kuo; Chao, You-Chen; Yeh, Ming-Kung

    2008-01-01

    Parenteral nutrition (PN) solution contains various concentrations of dextrose, amino acids, lipids, vitamins, electrolytes, and trace elements. Incorrect preparation of PN solution could lead to patient death. In this study we used the refractive index as a quality assurance tool to monitor the preparation of PN solution. Refractive indices of single nutrient components and PN solutions consisting of various concentrations of dextrose, amino acids, electrolytes, and lipids were measured. A mathematical equation and its linear plot were generated then used to predict the refractive index of the PN solution. The best-fit refractive index for PN solution (i.e., the predicted refractive index)=0.9798x(% dextrose)+1.2889x(% amino acids)+1.1017x(% lipids)+0.9440x(% sum of the electrolytes)+0.5367 (r2=0.99). This equation was validated by comparing the measured refractive indices of 500 clinical PN solutions to their predicted refractive indices. We found that 2 of the 500 prepared samples (0.4%) had less than the predicted refractive index (<95%). Refractive index can be used as a reliable quality assurance tool for monitoring PN preparation. Such information can be obtained at the bedside and used to confirm the accuracy of the PN solution composition.

  9. INVOLVEMENT OF MULTIPLE MOLECULAR PATHWAYS IN THE GENETICS OF OCULAR REFRACTION AND MYOPIA.

    PubMed

    Wojciechowski, Robert; Cheng, Ching-Yu

    2018-01-01

    The prevalence of myopia has increased dramatically worldwide within the last three decades. Recent studies have shown that refractive development is influenced by environmental, behavioral, and inherited factors. This review aims to analyze recent progress in the genetics of refractive error and myopia. A comprehensive literature search of PubMed and OMIM was conducted to identify relevant articles in the genetics of refractive error. Genome-wide association and sequencing studies have increased our understanding of the genetics involved in refractive error. These studies have identified interesting candidate genes. All genetic loci discovered to date indicate that refractive development is a heterogeneous process mediated by a number of overlapping biological processes. The exact mechanisms by which these biological networks regulate eye growth are poorly understood. Although several individual genes and/or molecular pathways have been investigated in animal models, a systematic network-based approach in modeling human refractive development is necessary to understand the complex interplay between genes and environment in refractive error. New biomedical technologies and better-designed studies will continue to refine our understanding of the genetics and molecular pathways of refractive error, and may lead to preventative and therapeutic measures to combat the myopia epidemic.

  10. Characteristics of the anomalous refractive conditions in Nigeria

    NASA Astrophysics Data System (ADS)

    Emmanuel, I.; Adeyemi, B.; Ogolo, E. O.; Adediji, A. T.

    2017-11-01

    The thirty six years (1979-2014) meteorological data needed to calculate refractivity gradient is obtained from Era interim build on IFS CY31r2 model. Diurnal cycle of ducting occurrence for four seasons in Nigeria were analysed from refractivity gradient. Percentage occurrence of anomalous propagation in thirty locations across Nigeria were estimated. It is discovered that ducting is more frequent at mid night and early morning which also vary seasonally and regionally across the country. Highest percentage of 94 % of ducting and zero occurrence of sub refractive is obtained in Lagos. Highest percentage of 34.24 % and 45.62 % of super refractive and sub refractive are obtained in Sapele and Oban hill, respectively. Minimum percentage of 21.9 % and 4.33 % of ducting and super refractive were obtained for Calabar and Gashua, respectively. The minimum frequency for a radio wave to be trapped within Nigeria troposphere varies between 0.045 GHz and 0.11 GHz. The occurrence of anomalous propagation condition, such as ducts, super refractive and sub refractive provide valuable information about the propagation of radio waves over Nigeria, which will assist the radio engineer in their planning and designing of radio circuitry.

  11. The inverse problem of refraction travel times, part II: Quantifying refraction nonuniqueness using a three-layer model

    USGS Publications Warehouse

    Ivanov, J.; Miller, R.D.; Xia, J.; Steeples, D.

    2005-01-01

    This paper is the second of a set of two papers in which we study the inverse refraction problem. The first paper, "Types of Geophysical Nonuniqueness through Minimization," studies and classifies the types of nonuniqueness that exist when solving inverse problems depending on the participation of a priori information required to obtain reliable solutions of inverse geophysical problems. In view of the classification developed, in this paper we study the type of nonuniqueness associated with the inverse refraction problem. An approach for obtaining a realistic solution to the inverse refraction problem is offered in a third paper that is in preparation. The nonuniqueness of the inverse refraction problem is examined by using a simple three-layer model. Like many other inverse geophysical problems, the inverse refraction problem does not have a unique solution. Conventionally, nonuniqueness is considered to be a result of insufficient data and/or error in the data, for any fixed number of model parameters. This study illustrates that even for overdetermined and error free data, nonlinear inverse refraction problems exhibit exact-data nonuniqueness, which further complicates the problem of nonuniqueness. By evaluating the nonuniqueness of the inverse refraction problem, this paper targets the improvement of refraction inversion algorithms, and as a result, the achievement of more realistic solutions. The nonuniqueness of the inverse refraction problem is examined initially by using a simple three-layer model. The observations and conclusions of the three-layer model nonuniqueness study are used to evaluate the nonuniqueness of more complicated n-layer models and multi-parameter cell models such as in refraction tomography. For any fixed number of model parameters, the inverse refraction problem exhibits continuous ranges of exact-data nonuniqueness. Such an unfavorable type of nonuniqueness can be uniquely solved only by providing abundant a priori information. Insufficient a priori information during the inversion is the reason why refraction methods often may not produce desired results or even fail. This work also demonstrates that the application of the smoothing constraints, typical when solving ill-posed inverse problems, has a dual and contradictory role when applied to the ill-posed inverse problem of refraction travel times. This observation indicates that smoothing constraints may play such a two-fold role when applied to other inverse problems. Other factors that contribute to inverse-refraction-problem nonuniqueness are also considered, including indeterminacy, statistical data-error distribution, numerical error and instability, finite data, and model parameters. ?? Birkha??user Verlag, Basel, 2005.

  12. Population-based assessment of sensitivity and specificity of a pinhole for detection of significant refractive errors in the community.

    PubMed

    Marmamula, Srinivas; Keeffe, Jill E; Narsaiah, Saggam; Khanna, Rohit C; Rao, Gullapalli N

    2014-11-01

    Measurements of refractive errors through subjective or automated refraction are not always possible in rapid assessment studies and community vision screening programs; however, measurements of vision with habitual correction and with a pinhole can easily be made. Although improvements in vision with a pinhole are assumed to mean that a refractive error is present, no studies have investigated the magnitude of improvement in vision with pinhole that is predictive of refractive error. The aim was to measure the sensitivity and specificity of 'vision improvement with pinhole' in predicting the presence of refractive error in a community setting. Vision and vision with pinhole were measured using a logMAR chart for 488 of 582 individuals aged 15 to 50 years. Refractive errors were measured using non-cycloplegic autorefraction and subjective refraction. The presence of refractive error was defined using spherical equivalent refraction (SER) at two levels: SER greater than ± 0.50 D sphere (DS) and SER greater than ±1.00 DS. Three definitions for significant improvement in vision with a pinhole were used: 1. Presenting vision less than 6/12 and improving to 6/12 or better, 2. Improvement in vision of more than one logMAR line and 3. Improvement in vision of more than two logMAR lines. For refractive error defined as spherical equivalent refraction greater than ± 0.50 DS, the sensitivities and specificities for the pinhole test predicting the presence of refractive error were 83.9 per cent (95% CI: 74.5 to 90.9) and 98.8 per cent (95% CI: 97.1 to 99.6), respectively for definition 1. Definition 2 had a sensitivity 89.7 per cent (95% CI: 81.3 to 95.2) and specificity 88.0 per cent (95% CI: 4.4 to 91.0). Definition 3 had a sensitivity of 75.9 per cent (95% CI: 65.5 to 84.4) and specificity of 97.8 per cent (95% CI: 95.8 to 99.0). Similar results were found with spherical equivalent refraction greater than ±1.00 DS, when tested against the three pinhole-based definitions. Refractive error definitions based on improvement in vision with the pinhole shows good sensitivity and specificity at predicting the presence of significant refractive errors. These definitions can be used in rapid assessment surveys and community-based vision screenings. © 2014 The Authors. Clinical and Experimental Optometry © 2014 Optometrists Association Australia.

  13. Uniform refraction in negative refractive index materials.

    PubMed

    Gutiérrez, Cristian E; Stachura, Eric

    2015-11-01

    We study the problem of constructing an optical surface separating two homogeneous, isotropic media, one of which has a negative refractive index. In doing so, we develop a vector form of Snell's law, which is used to study surfaces possessing a certain uniform refraction property, in both the near- and far-field cases. In the near-field problem, unlike the case when both materials have positive refractive indices, we show that the resulting surfaces can be neither convex nor concave.

  14. Do Peripheral Refraction and Aberration Profiles Vary with the Type of Myopia? - An Illustration Using a Ray-Tracing Approach

    PubMed Central

    Bakaraju, Ravi C.; Ehrmann, Klaus; Papas, Eric B.; Ho, Arthur

    2010-01-01

    Purpose Myopia is considered to be the most common refractive error occurring in children and young adults, around the world. Motivated to elucidate how the process of emmetropization is disrupted, potentially causing myopia and its progression, researchers have shown great interest in peripheral refraction. This study assessed the effect of the myopia type, either refractive or axial, on peripheral refraction and aberration profiles. Methods Using customized schematic eye models for myopia in a ray tracing algorithm, peripheral aberrations, including the refractive error, were calculated as a function of myopia type. Results In all the selected models, hyperopic shifts in the mean spherical equivalent (MSE) component were found whose magnitude seemed to be largely dependent on the field angle. The MSE profiles showed larger hyperopic shifts for the axial type of myopic models than the refractive ones and were evident in -4 and -6 D prescriptions. Additionally, greater levels of astigmatic component (J180) were also seen in axial-length-dependent models, while refractive models showed higher levels of spherical aberration and coma. Conclusion This study has indicated that myopic eyes with primarily an axial component may have a greater risk of progression than their refractive counterparts albeit with the same degree of refractive error. This prediction emerges from the presented theoretical ray tracing model and, therefore, requires clinical confirmation.

  15. PREVALENCE OF REFRACTIVE ERRORS IN MADRASSA STUDENTS OF HARIPUR DISTRICT.

    PubMed

    Atta, Zoia; Arif, Abdus Salam; Ahmed, Iftikhar; Farooq, Umer

    2015-01-01

    Visual impairment due to refractive errors is one of the most common problems among school-age children and is the second leading cause of treatable blindness. The Right to Sight, a global initiative launched by a coalition of non-government organizations and the World Health Organization (WHO), aims to eliminate avoidable visual impairment and blindness at a global level. In order to achieve this goal it is important to know the prevalence of different refractive errors in a community. Children and teenagers are the most susceptible groups to be affected by refractive errors. So, this population needs to be screened for different types of refractive errors. The study was done with the objective to find the frequency of different types of refractive errors in students of madrassas between the ages of 5-20 years in Haripur. This cross sectional study was done with 300 students between ages of 5-20 years in Madrassas of Haripur. The students were screened for refractive errors and the types of the errors were noted. After screening for refractive errors-the glasses were prescribed to the students. Myopia being 52.6% was the most frequent refractive error in students, followed by hyperopia 28.4% and astigmatism 19%. This study showed that myopia is an important problem in madrassa population. Females and males are almost equally affected. Spectacle correction of refractive errors is the cheapest and easy solution of this problem.

  16. Experimental validation of systematically designed acoustic hyperbolic meta material slab exhibiting negative refraction

    NASA Astrophysics Data System (ADS)

    Christiansen, Rasmus E.; Sigmund, Ole

    2016-09-01

    This Letter reports on the experimental validation of a two-dimensional acoustic hyperbolic metamaterial slab optimized to exhibit negative refractive behavior. The slab was designed using a topology optimization based systematic design method allowing for tailoring the refractive behavior. The experimental results confirm the predicted refractive capability as well as the predicted transmission at an interface. The study simultaneously provides an estimate of the attenuation inside the slab stemming from the boundary layer effects—insight which can be utilized in the further design of the metamaterial slabs. The capability of tailoring the refractive behavior opens possibilities for different applications. For instance, a slab exhibiting zero refraction across a wide angular range is capable of funneling acoustic energy through it, while a material exhibiting the negative refractive behavior across a wide angular range provides lensing and collimating capabilities.

  17. Fully interferometric controllable anomalous refraction efficiency using cross modulation with plasmonic metasurfaces.

    PubMed

    Liu, Zhaocheng; Chen, Shuqi; Li, Jianxiong; Cheng, Hua; Li, Zhancheng; Liu, Wenwei; Yu, Ping; Xia, Ji; Tian, Jianguo

    2014-12-01

    We present a method of fully interferometric, controllable anomalous refraction efficiency by introducing cross-modulated incident light based on plasmonic metasurfaces. Theoretical analyses and numerical simulations indicate that the anomalous and ordinary refracted beams generated from two opposite-helicity incident beams and following the generalized Snell's law will have a superposition for certain incident angles, and the anomalous refraction efficiency can be dynamically controlled by changing the relative phase of the incident sources. As the incident wavelength nears the resonant wavelength of the plasmonic metasurfaces, two equal-amplitude incident beams with opposite helicity can be used to control the anomalous refraction efficiency. Otherwise, two unequal-amplitude incident beams with opposite helicity can be used to fully control the anomalous refraction efficiency. This Letter may offer a further step in the development of controllable anomalous refraction.

  18. Influence of changes in an eye's optical system on refraction

    NASA Astrophysics Data System (ADS)

    Bartkowska, Janina

    1998-10-01

    The optical system of eye is composed of cornea, lens, anterior chamber, and vitreous body. In the standard schematic eye there are 6 refracting surfaces. The changes of the curvature radii, of the distances between them, of the refractive indices influence the ametropia, refractive power of the eye and retinal image size. The influence of these changes can be appreciated by ray tracing or by an analytical method. There are presented simplified formulae for the differentials of ametropia and refractive power of the eye with respect to the surfaces curvatures, refracting power of cornea and lens, refractive indices. The relations are valid too for bigger changes if ametropia is measured in the cornea vertex. The formulae for the differentials with respect to distances, lens translation, eye axis length are valid if ametropia is measured in the object focus of the eye.

  19. Combined Theoretical and Experimental Study of Refractive Indices of Water-Acetonitrile-Salt Systems.

    PubMed

    An, Ni; Zhuang, Bilin; Li, Minglun; Lu, Yuyuan; Wang, Zhen-Gang

    2015-08-20

    We propose a simple theoretical formula for describing the refractive indices in binary liquid mixtures containing salt ions. Our theory is based on the Clausius-Mossotti equation; it gives the refractive index of the mixture in terms of the refractive indices of the pure liquids and the polarizability of the ionic species, by properly accounting for the volume change upon mixing. The theoretical predictions are tested by extensive experimental measurements of the refractive indices for water-acetonitrile-salt systems for several liquid compositions, different salt species, and a range of salt concentrations. Excellent agreement is obtained in all cases, especially at low salt concentrations, with no fitting parameters. A simplified expression of the refractive index for low salt concentration is also given, which can be the theoretical basis for determination of salt concentration using refractive index measurements.

  20. Trial Frame Refraction versus Autorefraction among New Patients in a Low-Vision Clinic

    PubMed Central

    DeCarlo, Dawn K.; McGwin, Gerald; Searcey, Karen; Gao, Liyan; Snow, Marsha; Waterbor, John; Owsley, Cynthia

    2013-01-01

    Purpose. To determine the relationship between refractive error as measured by autorefraction and that measured by trial frame refraction among a sample of adults with vision impairment seen in a university-based low-vision clinic and to determine if autorefraction might be a suitable replacement for trial frame refraction. Methods. A retrospective chart review of all new patients 19 years or older seen over an 18-month period was conducted and the following data collected: age, sex, primary ocular diagnosis, entering distance visual acuity, habitual correction, trial frame refraction, autorefraction, and distance visual acuity measured after trial frame refraction. Trial frame refraction and autorefraction were compared using paired t-tests, intraclass correlations, and Bland-Altman plots. Results. Final analyses included 440 patients for whom both trial frame refraction and autorefraction data were available for the better eye. Participants were mostly female (59%) with a mean age of 68 years (SD = 20). Age-related macular degeneration was the most common etiology for vision impairment (44%). Values for autorefraction and trial frame refraction were statistically different, but highly correlated for the spherical equivalent power (r = 0.92), the cylinder power (r = 0.80) and overall blurring strength (0.89). Although the values of the cross-cylinders J0 and J45 were similar, they were poorly correlated (0.08 and 0.15, respectively). The range of differences in spherical equivalent power was large (−8.6 to 4.9). Conclusions. Autorefraction is highly correlated with trial frame refraction. Differences are sometimes substantial, making autorefraction an unsuitable substitute for trial frame refraction. PMID:23188726

  1. Correlations between Preoperative Angle Parameters and Postoperative Unpredicted Refractive Errors after Cataract Surgery in Open Angle Glaucoma (AOD 500).

    PubMed

    Lee, Wonseok; Bae, Hyoung Won; Lee, Si Hyung; Kim, Chan Yun; Seong, Gong Je

    2017-03-01

    To assess the accuracy of intraocular lens (IOL) power prediction for cataract surgery with open angle glaucoma (OAG) and to identify preoperative angle parameters correlated with postoperative unpredicted refractive errors. This study comprised 45 eyes from 45 OAG subjects and 63 eyes from 63 non-glaucomatous cataract subjects (controls). We investigated differences in preoperative predicted refractive errors and postoperative refractive errors for each group. Preoperative predicted refractive errors were obtained by biometry (IOL-master) and compared to postoperative refractive errors measured by auto-refractometer 2 months postoperatively. Anterior angle parameters were determined using swept source optical coherence tomography. We investigated correlations between preoperative angle parameters [angle open distance (AOD); trabecular iris surface area (TISA); angle recess area (ARA); trabecular iris angle (TIA)] and postoperative unpredicted refractive errors. In patients with OAG, significant differences were noted between preoperative predicted and postoperative real refractive errors, with more myopia than predicted. No significant differences were recorded in controls. Angle parameters (AOD, ARA, TISA, and TIA) at the superior and inferior quadrant were significantly correlated with differences between predicted and postoperative refractive errors in OAG patients (-0.321 to -0.408, p<0.05). Superior quadrant AOD 500 was significantly correlated with postoperative refractive differences in multivariate linear regression analysis (β=-2.925, R²=0.404). Clinically unpredicted refractive errors after cataract surgery were more common in OAG than in controls. Certain preoperative angle parameters, especially AOD 500 at the superior quadrant, were significantly correlated with these unpredicted errors.

  2. Correlations between Preoperative Angle Parameters and Postoperative Unpredicted Refractive Errors after Cataract Surgery in Open Angle Glaucoma (AOD 500)

    PubMed Central

    Lee, Wonseok; Bae, Hyoung Won; Lee, Si Hyung; Kim, Chan Yun

    2017-01-01

    Purpose To assess the accuracy of intraocular lens (IOL) power prediction for cataract surgery with open angle glaucoma (OAG) and to identify preoperative angle parameters correlated with postoperative unpredicted refractive errors. Materials and Methods This study comprised 45 eyes from 45 OAG subjects and 63 eyes from 63 non-glaucomatous cataract subjects (controls). We investigated differences in preoperative predicted refractive errors and postoperative refractive errors for each group. Preoperative predicted refractive errors were obtained by biometry (IOL-master) and compared to postoperative refractive errors measured by auto-refractometer 2 months postoperatively. Anterior angle parameters were determined using swept source optical coherence tomography. We investigated correlations between preoperative angle parameters [angle open distance (AOD); trabecular iris surface area (TISA); angle recess area (ARA); trabecular iris angle (TIA)] and postoperative unpredicted refractive errors. Results In patients with OAG, significant differences were noted between preoperative predicted and postoperative real refractive errors, with more myopia than predicted. No significant differences were recorded in controls. Angle parameters (AOD, ARA, TISA, and TIA) at the superior and inferior quadrant were significantly correlated with differences between predicted and postoperative refractive errors in OAG patients (-0.321 to -0.408, p<0.05). Superior quadrant AOD 500 was significantly correlated with postoperative refractive differences in multivariate linear regression analysis (β=-2.925, R2=0.404). Conclusion Clinically unpredicted refractive errors after cataract surgery were more common in OAG than in controls. Certain preoperative angle parameters, especially AOD 500 at the superior quadrant, were significantly correlated with these unpredicted errors. PMID:28120576

  3. Uncorrected and corrected refractive error experiences of Nepalese adults: a qualitative study.

    PubMed

    Kandel, Himal; Khadka, Jyoti; Shrestha, Mohan Krishna; Sharma, Sadhana; Neupane Kandel, Sandhya; Dhungana, Purushottam; Pradhan, Kishore; Nepal, Bhagavat P; Thapa, Suman; Pesudovs, Konrad

    2018-04-01

    The aim of this study was to explore the impact of corrected and uncorrected refractive error (URE) on Nepalese people's quality of life (QoL), and to compare the QoL status between refractive error subgroups. Participants were recruited from Tilganga Institute of Ophthalmology and Dhulikhel Hospital, Nepal. Semi-structured in-depth interviews were conducted with 101 people with refractive error. Thematic analysis was used with matrices produced to compare the occurrence of themes and categories across participants. Themes were identified using an inductive approach. Seven major themes emerged that determined refractive error-specific QoL: activity limitation, inconvenience, health concerns, psycho-social impact, economic impact, general and ocular comfort symptoms, and visual symptoms. Activity limitation, economic impact, and symptoms were the most important themes for the participants with URE, whereas inconvenience associated with wearing glasses was the most important issue in glasses wearers. Similarly, possibilities of having side effects or complications were the major concerns for participants wearing contact lens. In general, refractive surgery addressed socio-emotional impact of wearing glasses or contact lens. However, the surgery participants had concerns such as possibility of having to wear glasses again due to relapse of refractive error. Impact of refractive error on people's QoL is multifaceted. Significance of the identified themes varies by refractive error subgroups. Refractive correction may not always address QoL impact of URE but often add unique QoL issues. This study findings also provide content for developing an item-bank for quantitatively measuring refractive error-specific QoL in developing country setting.

  4. Trial frame refraction versus autorefraction among new patients in a low-vision clinic.

    PubMed

    DeCarlo, Dawn K; McGwin, Gerald; Searcey, Karen; Gao, Liyan; Snow, Marsha; Waterbor, John; Owsley, Cynthia

    2013-01-02

    To determine the relationship between refractive error as measured by autorefraction and that measured by trial frame refraction among a sample of adults with vision impairment seen in a university-based low-vision clinic and to determine if autorefraction might be a suitable replacement for trial frame refraction. A retrospective chart review of all new patients 19 years or older seen over an 18-month period was conducted and the following data collected: age, sex, primary ocular diagnosis, entering distance visual acuity, habitual correction, trial frame refraction, autorefraction, and distance visual acuity measured after trial frame refraction. Trial frame refraction and autorefraction were compared using paired t-tests, intraclass correlations, and Bland-Altman plots. Final analyses included 440 patients for whom both trial frame refraction and autorefraction data were available for the better eye. Participants were mostly female (59%) with a mean age of 68 years (SD = 20). Age-related macular degeneration was the most common etiology for vision impairment (44%). Values for autorefraction and trial frame refraction were statistically different, but highly correlated for the spherical equivalent power (r = 0.92), the cylinder power (r = 0.80) and overall blurring strength (0.89). Although the values of the cross-cylinders J(0) and J(45) were similar, they were poorly correlated (0.08 and 0.15, respectively). The range of differences in spherical equivalent power was large (-8.6 to 4.9). Autorefraction is highly correlated with trial frame refraction. Differences are sometimes substantial, making autorefraction an unsuitable substitute for trial frame refraction.

  5. Survey of Radar Refraction Error Corrections

    DTIC Science & Technology

    2016-11-01

    ELECTRONIC TRAJECTORY MEASUREMENTS GROUP RCC 266-16 SURVEY OF RADAR REFRACTION ERROR CORRECTIONS DISTRIBUTION A: Approved for...DOCUMENT 266-16 SURVEY OF RADAR REFRACTION ERROR CORRECTIONS November 2016 Prepared by Electronic...This page intentionally left blank. Survey of Radar Refraction Error Corrections, RCC 266-16 iii Table of Contents Preface

  6. A Wind Dependent Desert Aerosol Model: Radiative Properties

    DTIC Science & Technology

    1988-04-19

    Source Regions and Transport Characteristics 5 2.2 Size Distributions 6 2.3 Composition 8 2.4 Effects of Wind 10 2.5 Indices of Refraction 12 2.5.1 An...Hematite Concentrations of 0, 5, and 10 %, (a) O-Ray and (b) E-Ray 44 8 . Imaginary Part of the Index of Refraction for Sand Having Hematite...rarbonaceous Material 31 8 . Indices of Refraction "or Ammonium Sulfate 32 9. Indices of Refraction for the 0-Ray of Quartz 35 10 . Indices of Refraction for the

  7. Study of all-angle negative refraction of light in metal-dielectric-metal multilayered structures based on generalized formulas of reflection and refraction

    NASA Astrophysics Data System (ADS)

    Chen, Jiangwei; Liu, Jun; Xu, Weidong

    2017-09-01

    In this paper, refraction behaviors of light in both metal single-layered film and metal-dielectric-metal multilayered films are investigated based on the generalized formulas of reflection and refraction. The obtained results, especially, dependence of power refractive index on incident angles for a light beam traveling through a metal-dielectric-metal multilayered structure, are well consistent with the experimental observations. Our work may offer a new angle of view to understand the all-angle negative refraction of light in metal-dielectric-metal multilayered structures, and provide a convenient approach to optimize the devised design and address the issue on making the perfect lens.

  8. Explaining negative refraction without negative refractive indices.

    PubMed

    Talalai, Gregory A; Garner, Timothy J; Weiss, Steven J

    2018-03-01

    Negative refraction through a triangular prism may be explained without assigning a negative refractive index to the prism by using array theory. For the case of a beam incident upon the wedge, the array theory accurately predicts the beam transmission angle through the prism and provides an estimate of the frequency interval at which negative refraction occurs. The hypotenuse of the prism has a staircase shape because it is built of cubic unit cells. The large phase delay imparted by each unit cell, combined with the staircase shape of the hypotenuse, creates the necessary conditions for negative refraction. Full-wave simulations using the finite-difference time-domain method show that array theory accurately predicts the beam transmission angle.

  9. Nature of the refractive errors in rhesus monkeys (Macaca mulatta) with experimentally induced ametropias.

    PubMed

    Qiao-Grider, Ying; Hung, Li-Fang; Kee, Chea-Su; Ramamirtham, Ramkumar; Smith, Earl L

    2010-08-23

    We analyzed the contribution of individual ocular components to vision-induced ametropias in 210 rhesus monkeys. The primary contribution to refractive-error development came from vitreous chamber depth; a minor contribution from corneal power was also detected. However, there was no systematic relationship between refractive error and anterior chamber depth or between refractive error and any crystalline lens parameter. Our results are in good agreement with previous studies in humans, suggesting that the refractive errors commonly observed in humans are created by vision-dependent mechanisms that are similar to those operating in monkeys. This concordance emphasizes the applicability of rhesus monkeys in refractive-error studies. Copyright 2010 Elsevier Ltd. All rights reserved.

  10. Corrective Techniques and Future Directions for Treatment of Residual Refractive Error Following Cataract Surgery

    PubMed Central

    Moshirfar, Majid; McCaughey, Michael V; Santiago-Caban, Luis

    2015-01-01

    Postoperative residual refractive error following cataract surgery is not an uncommon occurrence for a large proportion of modern-day patients. Residual refractive errors can be broadly classified into 3 main categories: myopic, hyperopic, and astigmatic. The degree to which a residual refractive error adversely affects a patient is dependent on the magnitude of the error, as well as the specific type of intraocular lens the patient possesses. There are a variety of strategies for resolving residual refractive errors that must be individualized for each specific patient scenario. In this review, the authors discuss contemporary methods for rectification of residual refractive error, along with their respective indications/contraindications, and efficacies. PMID:25663845

  11. Nature of the Refractive Errors in Rhesus Monkeys (Macaca mulatta) with Experimentally Induced Ametropias

    PubMed Central

    Qiao-Grider, Ying; Hung, Li-Fang; Kee, Chea-su; Ramamirtham, Ramkumar; Smith, Earl L.

    2010-01-01

    We analyzed the contribution of individual ocular components to vision-induced ametropias in 210 rhesus monkeys. The primary contribution to refractive-error development came from vitreous chamber depth; a minor contribution from corneal power was also detected. However, there was no systematic relationship between refractive error and anterior chamber depth or between refractive error and any crystalline lens parameter. Our results are in good agreement with previous studies in humans, suggesting that the refractive errors commonly observed in humans are created by vision-dependent mechanisms that are similar to those operating in monkeys. This concordance emphasizes the applicability of rhesus monkeys in refractive-error studies. PMID:20600237

  12. Corrective Techniques and Future Directions for Treatment of Residual Refractive Error Following Cataract Surgery.

    PubMed

    Moshirfar, Majid; McCaughey, Michael V; Santiago-Caban, Luis

    2014-12-01

    Postoperative residual refractive error following cataract surgery is not an uncommon occurrence for a large proportion of modern-day patients. Residual refractive errors can be broadly classified into 3 main categories: myopic, hyperopic, and astigmatic. The degree to which a residual refractive error adversely affects a patient is dependent on the magnitude of the error, as well as the specific type of intraocular lens the patient possesses. There are a variety of strategies for resolving residual refractive errors that must be individualized for each specific patient scenario. In this review, the authors discuss contemporary methods for rectification of residual refractive error, along with their respective indications/contraindications, and efficacies.

  13. Low cost fiber optic sensing of sugar solution

    NASA Astrophysics Data System (ADS)

    Muthuraju, M. E.; Patlolla, Anurag Reddy; Vadakkapattu Canthadai, Badrinath; Pachava, Vengalrao

    2015-03-01

    The demand for highly sensitive and reliable sensors to assess the refractive index of liquid get many applications in chemical and biomedical areas. Indeed, the physical parameters such as concentration, pressure and density, etc., can be found using the refractive index of liquid. In contrast to the conventional refractometer for measurement, optical fiber sensor has several advantages like remote sensing, small in size, low cost, immune to EMI etc., In this paper we have discussed determination of refractive index of sugar solution using optical fiber. An intensity modulated low cost plastic fiber optic refractive index sensor has been designed for the study. The sensor is based on principle of change in angle of reflected light caused by refractive index change of the medium surrounding the fiber. The experimental results obtained for the sugar solution of different refractive indices prove that the fiber optic sensor is cable of measuring the refractive indices as well as the concentrations.

  14. Pressure-dependent refractive indices of gases by THz time-domain spectroscopy.

    PubMed

    Sang, Bark Hyeon; Jeon, Tea-In

    2016-12-12

    Noncontact terahertz time-domain spectroscopy was employed to measure pressure-dependent refractive indices of gases such as helium (He), argon (Ar), krypton (Kr), oxygen (O2), nitrogen (N2), methane (CH4), and carbon dioxide (CO2). The refractive indices of these gases scaled linearly with pressure, for pressures in the 55-3,750 torr range. At the highest pressure, the refractive indices ((n-1) x 106) of He and CO2 were 170 and 2,390, respectively. The refractive index of CO2 was 14.1-fold higher than that of He, owing to the stronger polarizability of CO2. Although the studied gases differed in terms of their molecular structure, their refractive indices were strongly determined by polarizability. The measured refractive indices agreed well with the theoretical calculations.

  15. Refractive-index measurement and inverse correction using optical coherence tomography.

    PubMed

    Stritzel, Jenny; Rahlves, Maik; Roth, Bernhard

    2015-12-01

    We describe a novel technique for determination of the refractive index of hard biological tissue as well as nonopaque technical samples based on optical coherence tomography (OCT). Our method relies on an inverse refractive-index correction (I-RIC), which matches a measured feature geometry distorted due to refractive-index boundaries to its real geometry. For known feature geometry, the refractive index can be determined with high precision from the best match between the distorted and corrected images. We provide experimental data for refractive-index measurements on a polymethylmethacrylate (PMMA) and on an ex vivo porcine cranial-bone, which are compared to reference measurements and previously published data. Our method is potentially capable of in vivo measurements on rigid biological tissue such as bone as, for example, is required to improve guidance in robot-aided surgical interventions and also for retrieving complex refractive-index profiles of compound materials.

  16. Highly tunable refractive index visible-light metasurface from block copolymer self-assembly.

    PubMed

    Kim, Ju Young; Kim, Hyowook; Kim, Bong Hoon; Chang, Taeyong; Lim, Joonwon; Jin, Hyeong Min; Mun, Jeong Ho; Choi, Young Joo; Chung, Kyungjae; Shin, Jonghwa; Fan, Shanhui; Kim, Sang Ouk

    2016-09-29

    The refractive index of natural transparent materials is limited to 2-3 throughout the visible wavelength range. Wider controllability of the refractive index is desired for novel optical applications such as nanoimaging and integrated photonics. We report that metamaterials consisting of period and symmetry-tunable self-assembled nanopatterns can provide a controllable refractive index medium for a broad wavelength range, including the visible region. Our approach exploits the independent control of permeability and permittivity with nanoscale objects smaller than the skin depth. The precise manipulation of the interobject distance in block copolymer nanopatterns via pattern shrinkage increased the effective refractive index up to 5.10. The effective refractive index remains above 3.0 over more than 1,000 nm wavelength bandwidth. Spatially graded and anisotropic refractive indices are also obtained with the design of transitional and rotational symmetry modification.

  17. Highly tunable refractive index visible-light metasurface from block copolymer self-assembly

    PubMed Central

    Kim, Ju Young; Kim, Hyowook; Kim, Bong Hoon; Chang, Taeyong; Lim, Joonwon; Jin, Hyeong Min; Mun, Jeong Ho; Choi, Young Joo; Chung, Kyungjae; Shin, Jonghwa; Fan, Shanhui; Kim, Sang Ouk

    2016-01-01

    The refractive index of natural transparent materials is limited to 2–3 throughout the visible wavelength range. Wider controllability of the refractive index is desired for novel optical applications such as nanoimaging and integrated photonics. We report that metamaterials consisting of period and symmetry-tunable self-assembled nanopatterns can provide a controllable refractive index medium for a broad wavelength range, including the visible region. Our approach exploits the independent control of permeability and permittivity with nanoscale objects smaller than the skin depth. The precise manipulation of the interobject distance in block copolymer nanopatterns via pattern shrinkage increased the effective refractive index up to 5.10. The effective refractive index remains above 3.0 over more than 1,000 nm wavelength bandwidth. Spatially graded and anisotropic refractive indices are also obtained with the design of transitional and rotational symmetry modification. PMID:27683077

  18. Nondestructive measurement of the refractive index distribution of a glass molded lens by two-wavelength wavefronts.

    PubMed

    Sugimoto, Tomohiro

    2016-10-01

    This paper presents a nondestructive and non-exact-index-matching method for measuring the refractive index distribution of a glass molded lens with high refractivity. The method measures two-wavelength wavefronts of a test lens immersed in a liquid with a refractive index dispersion different from that of the test lens and calculates the refractive index distribution by eliminating the refractive index distribution error caused by the shape error of the test lens. The estimated uncertainties of the refractive index distributions of test lenses with nd≈1.77 and nd≈1.85 were 1.9×10-5  RMS and 2.4×10-5  RMS, respectively. I validated the proposed method by evaluating the agreement between the estimated uncertainties and experimental values.

  19. Interferometric Methods of Measuring Refractive Indices and Double-Refraction of Fibres.

    ERIC Educational Resources Information Center

    Hamza, A. A.; El-Kader, H. I. Abd

    1986-01-01

    Presents two methods used to measure the refractive indices and double-refraction of fibers. Experiments are described, with one involving the use of Pluta microscope in the double-beam interference technique, the other employing the multiple-beam technique. Immersion liquids are discussed that can be used in the experiments. (TW)

  20. Two-dimensional interferometric characterization of laser-induced refractive index profiles in bulk Topas polymer

    NASA Astrophysics Data System (ADS)

    Hessler, Steffen; Rosenberger, Manuel; Schmauss, Bernhard; Hellmann, Ralf

    2018-01-01

    In this paper we precisely determine laser-induced refractive index profiles created in cyclic olefin copolymer Topas 6017 employing a sophisticated phase shifting Mach-Zehnder interferometry approach. Beyond the usual one-dimensional modification depth measurement we highlight that for straight waveguide structures also a two-dimensional refractive index distribution can be directly obtained providing full information of a waveguide's exact cross section and its gradient refractive index contrast. Deployed as direct data input in optical waveguide simulation, the evaluated 2D refractive index profiles permit a detailed calculation of the waveguides' actual mode profiles. Furthermore, conventional one-dimensional interferometric measurements for refractive index depth profiles with varying total imposed laser fluence of a 248 nm KrF excimer laser are included to investigate the effect on refractive index modification depth. Maximum surface refractive index increase turns out to attain up to 1.86 ·10-3 enabling laser-written optical waveguide channels. Additionally, a comprehensive optical material characterization in terms of dispersion, thermo-optic coefficient and absorption measurement of unmodified and UV-modified Topas 6017 is carried out.

  1. In-fiber refractive index sensor based on single eccentric hole-assisted dual-core fiber.

    PubMed

    Yang, Jing; Guan, Chunying; Tian, Peixuan; Yuan, Tingting; Zhu, Zheng; Li, Ping; Shi, Jinhui; Yang, Jun; Yuan, Libo

    2017-11-01

    We propose a novel and simple in-fiber refractive index sensor based on resonant coupling, constructed by a short section of single eccentric hole-assisted dual-core fiber (SEHADCF) spliced between two single-mode fibers. The coupling characteristics of the SEHADCF are calculated numerically. The strong resonant coupling occurs when the fundamental mode of the center core phase-matches to that of the suspended core in the air hole. The effective refractive index of the fundamental mode of the suspended core can be obviously changed by injecting solution into the air hole. The responses of the proposed devices to the refractive index and temperature are experimentally measured. The refractive index sensitivity is 627.5 nm/refractive index unit in the refractive index range of 1.335-1.385. The sensor without solution filling is insensitive to temperature in the range of 30-90°C. The proposed refractive index sensor has outstanding advantages, such as simple fabrication, good mechanical strength, and excellent microfluidic channel, and will be of importance in biological detection, chemical analysis, and environment monitoring.

  2. [Nature or nurture: effects of parental ametropia on children's refractive errors].

    PubMed

    Landmann, A; Bechrakis, E

    2013-12-01

    The aim of this study was to quantify the degree of association between juvenile refraction errors and parental refraction status. Using a simple questionnaire we conducted a cross-sectional study to determine the prevalence and magnitudes of refractive errors and of parental refraction status in a sample (n=728) of 10- to 18-year-old Austrian grammar school students. Students with myopia or hyperopia were more likely to have ametropic parents and refraction was more myopic in juveniles with one or two parents being ametropic. The prevalence of myopia in children with 2 ametropic parents was 54%, decreasing to 35% in pupils with 1 and to 13% in children with no ametropic parents. The odds ratio for 1 and 2 compared with no ametropic parents was 8.3 and 3.7 for myopia and 1.3 and 1.6 for hyperopia, respectively. Furthermore, the data indicate a stronger influence of the maternal ametropia on children's refractive errors than paternal ametropia. Genetic factors play a significant role in refractive error and may be of dominant influence for school myopia under conditions of low environmental variation.

  3. Patterns in longitudinal growth of refraction in Southern Chinese children: cluster and principal component analysis

    PubMed Central

    Chen, Yanxian; Chang, Billy Heung Wing; Ding, Xiaohu; He, Mingguang

    2016-01-01

    In the present study we attempt to use hypothesis-independent analysis in investigating the patterns in refraction growth in Chinese children, and to explore the possible risk factors affecting the different components of progression, as defined by Principal Component Analysis (PCA). A total of 637 first-born twins in Guangzhou Twin Eye Study with 6-year annual visits (baseline age 7–15 years) were available in the analysis. Cluster 1 to 3 were classified after a partitioning clustering, representing stable, slow and fast progressing groups of refraction respectively. Baseline age and refraction, paternal refraction, maternal refraction and proportion of two myopic parents showed significant differences across the three groups. Three major components of progression were extracted using PCA: “Average refraction”, “Acceleration” and the combination of “Myopia stabilization” and “Late onset of refraction progress”. In regression models, younger children with more severe myopia were associated with larger “Acceleration”. The risk factors of “Acceleration” included change of height and weight, near work, and parental myopia, while female gender, change of height and weight were associated with “Stabilization”, and increased outdoor time was related to “Late onset of refraction progress”. We therefore concluded that genetic and environmental risk factors have different impacts on patterns of refraction progression. PMID:27874105

  4. Unbiased Estimation of Refractive State of Aberrated Eyes

    PubMed Central

    Martin, Jesson; Vasudevan, Balamurali; Himebaugh, Nikole; Bradley, Arthur; Thibos, Larry

    2011-01-01

    To identify unbiased methods for estimating the target vergence required to maximize visual acuity based on wavefront aberration measurements. Experiments were designed to minimize the impact of confounding factors that have hampered previous research. Objective wavefront refractions and subjective acuity refractions were obtained for the same monochromatic wavelength. Accommodation and pupil fluctuations were eliminated by cycloplegia. Unbiased subjective refractions that maximize visual acuity for high contrast letters were performed with a computer controlled forced choice staircase procedure, using 0.125 diopter steps of defocus. All experiments were performed for two pupil diameters (3mm and 6mm). As reported in the literature, subjective refractive error does not change appreciably when the pupil dilates. For 3 mm pupils most metrics yielded objective refractions that were about 0.1D more hyperopic than subjective acuity refractions. When pupil diameter increased to 6 mm, this bias changed in the myopic direction and the variability between metrics also increased. These inaccuracies were small compared to the precision of the measurements, which implies that most metrics provided unbiased estimates of refractive state for medium and large pupils. A variety of image quality metrics may be used to determine ocular refractive state for monochromatic (635nm) light, thereby achieving accurate results without the need for empirical correction factors. PMID:21777601

  5. Effects of light refraction on the accuracy of camera calibration and reconstruction in underwater motion analysis.

    PubMed

    Kwon, Young-Hoo; Casebolt, Jeffrey B

    2006-01-01

    One of the most serious obstacles to accurate quantification of the underwater motion of a swimmer's body is image deformation caused by refraction. Refraction occurs at the water-air interface plane (glass) owing to the density difference. Camera calibration-reconstruction algorithms commonly used in aquatic research do not have the capability to correct this refraction-induced nonlinear image deformation and produce large reconstruction errors. The aim of this paper is to provide a through review of: the nature of the refraction-induced image deformation and its behaviour in underwater object-space plane reconstruction; the intrinsic shortcomings of the Direct Linear Transformation (DLT) method in underwater motion analysis; experimental conditions that interact with refraction; and alternative algorithms and strategies that can be used to improve the calibration-reconstruction accuracy. Although it is impossible to remove the refraction error completely in conventional camera calibration-reconstruction methods, it is possible to improve the accuracy to some extent by manipulating experimental conditions or calibration frame characteristics. Alternative algorithms, such as the localized DLT and the double-plane method are also available for error reduction. The ultimate solution for the refraction problem is to develop underwater camera calibration and reconstruction algorithms that have the capability to correct refraction.

  6. Effects of light refraction on the accuracy of camera calibration and reconstruction in underwater motion analysis.

    PubMed

    Kwon, Young-Hoo; Casebolt, Jeffrey B

    2006-07-01

    One of the most serious obstacles to accurate quantification of the underwater motion of a swimmer's body is image deformation caused by refraction. Refraction occurs at the water-air interface plane (glass) owing to the density difference. Camera calibration-reconstruction algorithms commonly used in aquatic research do not have the capability to correct this refraction-induced nonlinear image deformation and produce large reconstruction errors. The aim of this paper is to provide a thorough review of: the nature of the refraction-induced image deformation and its behaviour in underwater object-space plane reconstruction; the intrinsic shortcomings of the Direct Linear Transformation (DLT) method in underwater motion analysis; experimental conditions that interact with refraction; and alternative algorithms and strategies that can be used to improve the calibration-reconstruction accuracy. Although it is impossible to remove the refraction error completely in conventional camera calibration-reconstruction methods, it is possible to improve the accuracy to some extent by manipulating experimental conditions or calibration frame characteristics. Alternative algorithms, such as the localized DLT and the double-plane method are also available for error reduction. The ultimate solution for the refraction problem is to develop underwater camera calibration and reconstruction algorithms that have the capability to correct refraction.

  7. Design of embedded system to determine liquid refractive index based on ultrasonic sensor using an ATMega328

    NASA Astrophysics Data System (ADS)

    Radiyonoa, Y.; Surantoro, S.; Pujayanto, P.; Budiharti, R.; Respati, Y. S.; Saputro, D. E.

    2018-05-01

    The occurrence of the broken pencil shadow into a glass of water becomes an interesting matter to be learned. The students of senior high school still find difficulty in determining liquid refractive index. To overcome this problem, it needs to develop an experimental tool to determine liquid refractive index by utilizing the newest technology. It is expected to be useful for students. This study is aimed to (1) make the design of physics learning experimental tool determinant of a liquid refractive index assisted by microcontroller based on ultrasonic sensors ATMega328 (2) explain the working principle and experimental result of liquid refractive indexing instrument assisted with ATMega328 microcontroller based ultrasonic sensor. This research used the experimental method. The result of the research shows design of physics learning experimental tool determinant of a liquid refractive index assisted by microcontroller based on ultrasonic sensors ATMega328 that has relative counting mistake of 0.36% on the measurement of aquades liquid refractive index, relative mistake of 0.18% on the 5% NaCl measurement, 0.24% on 5% glucose, and relative mistake of 0.50% on the measurement of 5 % fructose liquid refractive index. It has been created a proper device to be used in determining liquid refractive index.

  8. Quantification of scaling exponents and dynamical complexity of microwave refractivity in a tropical climate

    NASA Astrophysics Data System (ADS)

    Fuwape, Ibiyinka A.; Ogunjo, Samuel T.

    2016-12-01

    Radio refractivity index is used to quantify the effect of atmospheric parameters in communication systems. Scaling and dynamical complexities of radio refractivity across different climatic zones of Nigeria have been studied. Scaling property of the radio refractivity across Nigeria was estimated from the Hurst Exponent obtained using two different scaling methods namely: The Rescaled Range (R/S) and the detrended fluctuation analysis(DFA). The delay vector variance (DVV), Largest Lyapunov Exponent (λ1) and Correlation Dimension (D2) methods were used to investigate nonlinearity and the results confirm the presence of deterministic nonlinear profile in the radio refractivity time series. The recurrence quantification analysis (RQA) was used to quantify the degree of chaoticity in the radio refractivity across the different climatic zones. RQA was found to be a good measure for identifying unique fingerprint and signature of chaotic time series data. Microwave radio refractivity was found to be persistent and chaotic in all the study locations. The dynamics of radio refractivity increases in complexity and chaoticity from the Coastal region towards the Sahelian climate. The design, development and deployment of robust and reliable microwave communication link in the region will be greatly affected by the chaotic nature of radio refractivity in the region.

  9. Macroeconomic landscape of refractive surgery in the United States.

    PubMed

    Corcoran, Kevin J

    2015-07-01

    This review examines the economic history of refractive surgery and the decline of laser-assisted in-situ keratomileusis (LASIK) in the USA, and the emergence of refractive cataract surgery as an area of growth. Since it peaked in 2007 at 1.4 million procedures per year, LASIK has declined 50% in the USA, whereas refractive cataract surgery, including presbyopia-correcting intraocular lenses (IOLs), astigmatism-correcting IOLs, and femtosecond laser-assisted cataract surgery, has grown to 350 000 procedures per year, beginning in 2003. Patients are price-sensitive and responsive to publicity (good or bad) about refractive surgery and refractive cataract surgery. LASIK's decline has been partially offset by the emergence of refractive cataract surgery. About 11% of all cataract surgery in the USA involves presbyopia-correcting IOLs, astigmatism-correcting IOLs, or a femtosecond laser. From the surgeon's perspective, there are high barriers to entry into the marketplace for refractive surgery and refractive cataract surgery due to the high capital cost of excimer and femtosecond lasers, the high skill level required to deliver spectacular results to demanding patients who pay out of pocket, and the necessity to perform a high volume of surgeries to satisfy both of these requirements. Probably, less than 7% of US cataract surgeons can readily meet all of these requirements.

  10. Pattern of refractive errors among the Nepalese population: a retrospective study.

    PubMed

    Shrestha, S P; Bhat, K S; Binu, V S; Barthakur, R; Natarajan, M; Subba, S H

    2010-01-01

    Refractive errors are a major cause of visual impairment in the population. To find the pattern of refractive errors among patients evaluated in a tertiary care hospital in the western region of Nepal. The present hospital-based retrospective study was conducted in the Department of Ophthalmology of the Manipal Teaching Hospital, situated in Pokhara, Nepal. Patients who had refractive error of at least 0.5 D (dioptre) were included for the study. During the study period, 15,410 patients attended the outpatient department and 10.8% of the patients were identified as having refractive error. The age of the patients in the present study ranged between 5 - 90 years. Myopia was the commonest refractive error followed by hypermetropia. There was no difference in the frequency of the type of refractive errors when they were defined using right the eye, the left eye or both the eyes. Males predominated among myopics and females predominated among hypermetropics. The majority of spherical errors was less than or equal to 2 D. Astigmatic power above 1D was rarely seen with hypermetropic astigmatism and was seen in around 13 % with myopic astigmatism. "Astigmatism against the rule" was more common than "astigmatism with the rule", irrespective of age. Refractive errors progressively shift along myopia up to the third decade and change to hypermetropia till the seventh decade. Hyperopic shift in the refractive error in young adults should be well noted while planning any refractive surgery in younger patients with myopia. © Nepal Ophthalmic Society.

  11. The effect of multifocal soft contact lenses on peripheral refraction.

    PubMed

    Kang, Pauline; Fan, Yvonne; Oh, Kelly; Trac, Kevin; Zhang, Frank; Swarbrick, Helen A

    2013-07-01

    To compare changes in peripheral refraction with single-vision (SV) and multifocal (MF) correction of distance central refraction with commercially available SV and MF soft contact lenses (SCLs) in young myopic adults. Thirty-four myopic adult subjects were fitted with Proclear Sphere and Proclear Multifocal SCLs to correct their manifest central refractive error. Central and peripheral refraction were measured with no lens wear and subsequently with the two different types of SCL correction. At baseline, refraction was myopic at all locations along the horizontal meridian. Peripheral refraction was relatively hyperopic compared with center at 30 and 35 degrees in the temporal visual field (VF) in low myopes, and at 30 and 35 degrees in the temporal VF, and 10, 30, and 35 degrees in the nasal VF in moderate myopes. Single-vision and MF distance correction with Proclear Sphere and Proclear Multifocal SCLs, respectively, caused a hyperopic shift in refraction at all locations in the horizontal VF. Compared with SV correction, MF SCL correction caused a significant relative myopic shift at all locations in the nasal VF in both low and moderate myopes and also at 35 degrees in the temporal VF in moderate myopes. Correction of central refractive error with SV and MF SCLs caused a hyperopic shift in both central and peripheral refraction at all positions in the horizontal meridian. Single-vision SCL correction caused the peripheral retina, which initially experienced absolute myopic defocus at baseline with no correction to experience an absolute hyperopic defocus. Multifocal SCL correction resulted in a relative myopic shift in peripheral refraction compared with SV SCL correction. This myopic shift may explain recent reports of reduced myopia progression rates with MF SCL correction.

  12. The Refractive Error of Professional Baseball Players.

    PubMed

    Laby, Daniel M; Kirschen, David G

    2017-05-01

    High levels of visual acuity are required to hit a baseball effectively. Research has shown that any decrease in vision is likely caused by low-order optical aberrations. This study is designed to validate the SVOne autorefractor, and describe the amount and type, of low-order optical aberrations present in a large cohort of professional baseball players. A retrospective chart review on the 608 Major League Baseball players evaluated during the 2016 Spring Training Season was performed. Results for a subset of players who had both manifest refraction as well as autorefraction were calculated. Subsequently, after determining the accuracy of the autorefraction system in this population, refractive results for the entire population were determined. There was a borderline statistically significant difference in mean spherical refractive error (M) between the manifest refraction and the SVOne auto refraction (-0.273D in the manifest refraction method vs. -0.503D in the SVOne method, P = .06) in the subset of athletes who underwent both tests. Additionally, there was no difference in the J0 or J45 cylindrical component vectors for each method. For the entire eligible population, the SVOne autorefraction system found a mean spherical refractive error (M) of -0.228D, a J0 value of -0.013D, and a J45 value of -0.040D. These data suggest that the SVOne autorefraction system is generally able to measure the refractive error in the baseball population. The system was slightly biased, often reporting more myopia in myopic subjects. Thus, careful evaluation of the refractive status of these athletes coupled with careful subjective refractive correction for those with less than average vision for baseball is strongly suggested.

  13. Theoretical analyses of the refractive implications of transepithelial PRK ablations.

    PubMed

    Arba Mosquera, Samuel; Awwad, Shady T

    2013-07-01

    To analyse the refractive implications of single-step, transepithelial photorefractive keratectomy (TransPRK) ablations. A simulation for quantifying the refractive implications of TransPRK ablations has been developed. The simulation includes a simple modelling of corneal epithelial profiles, epithelial ablation profiles as well as refractive ablation profiles, and allows the analytical quantification of the refractive implications of TransPRK in terms of wasted tissue, achieved optical zone (OZ) and induced refractive error. Wasted tissue occurs whenever the actual corneal epithelial profile is thinner than the applied epithelial ablation profile, achieved OZ is reduced whenever the actual corneal epithelial profile is thicker than the applied epithelial ablation profile and additional refractive errors are induced whenever the actual difference centre-to-periphery in the corneal epithelial profile deviates from the difference in the applied epithelial ablation profile. The refractive implications of TransPRK ablations can be quantified using simple theoretical simulations. These implications can be wasted tissue (∼14 µm, if the corneal epithelial profile is thinner than the ablated one), reduced OZ (if the corneal epithelial profile is thicker than ablated one, very severe for low corrections) and additional refractive errors (∼0.66 D, if the centre-to-periphery progression of the corneal epithelial profile deviates from the progression of the ablated one). When TransPRK profiles are applied to normal, not previously treated, non-pathologic corneas, no specific refractive implications associated to the transepithelial profile can be anticipated; TransPRK would provide refractive outcomes equal to those of standard PRK. Adjustments for the planned OZ and, in the event of retreatments, for the target sphere can be easily derived.

  14. Refractive errors among children, adolescents and adults attending eye clinics in Mexico.

    PubMed

    Gomez-Salazar, Francisco; Campos-Romero, Abraham; Gomez-Campaña, Humberto; Cruz-Zamudio, Cinthia; Chaidez-Felix, Mariano; Leon-Sicairos, Nidia; Velazquez-Roman, Jorge; Flores-Villaseñor, Hector; Muro-Amador, Secundino; Guadron-Llanos, Alma Marlene; Martinez-Garcia, Javier J; Murillo-Llanes, Joel; Sanchez-Cuen, Jaime; Llausas-Vargas, Alejando; Alapizco-Castro, Gerardo; Irineo-Cabrales, Ana; Graue-Hernandez, Enrique; Ramirez-Luquin, Tito; Canizalez-Roman, Adrian

    2017-01-01

    To assess the proportion of refractive errors in the Mexican population that visited primary care optometry clinics in fourteen states of Mexico. Refractive data from 676 856 patients aged 6 to 90y were collected from optometry clinics in fourteen states of Mexico between 2014 and 2015. The refractive errors were classified by the spherical equivalent (SE), as follows: sphere+½ cylinder. Myopia (SE>-0.50 D), hyperopia (SE>+0.50 D), emmetropia (-0.50≤SE≤+0.50), and astigmatism alone (cylinder≥-0.25 D). A negative cylinder was selected as a notation. The proportion (95% confidence interval) among all of the subjects was hyperopia 21.0% (20.9-21.0), emmetropia 40.7% (40.5-40.8), myopia 24.8% (24.7-24.9) and astigmatism alone 13.5% (13.4-13.5). Myopia was the most common refractive error and frequency seemed to increase among the young population (10 to 29 years old), however, hyperopia increased among the aging population (40 to 79 years old), and astigmatism alone showed a decreasing trend with age (6 to 90y; from 19.7% to 10.8%). There was a relationship between age and all refractive errors (approximately 60%, aged 50 and older). The proportion of any clinically important refractive error was higher in males (61.2%) than in females (58.3%; P <0.0001). From fourteen states that collected information, the proportion of refractive error showed variability in different geographical areas of Mexico. Myopia is the most common refractive error in the population studied. This study provides the first data on refractive error in Mexico. Further programs and studies must be developed to address the refractive errors needs of the Mexican population.

  15. Refractive errors among children, adolescents and adults attending eye clinics in Mexico

    PubMed Central

    Gomez-Salazar, Francisco; Campos-Romero, Abraham; Gomez-Campaña, Humberto; Cruz-Zamudio, Cinthia; Chaidez-Felix, Mariano; Leon-Sicairos, Nidia; Velazquez-Roman, Jorge; Flores-Villaseñor, Hector; Muro-Amador, Secundino; Guadron-Llanos, Alma Marlene; Martinez-Garcia, Javier J.; Murillo-Llanes, Joel; Sanchez-Cuen, Jaime; Llausas-Vargas, Alejando; Alapizco-Castro, Gerardo; Irineo-Cabrales, Ana; Graue-Hernandez, Enrique; Ramirez-Luquin, Tito; Canizalez-Roman, Adrian

    2017-01-01

    AIM To assess the proportion of refractive errors in the Mexican population that visited primary care optometry clinics in fourteen states of Mexico. METHODS Refractive data from 676 856 patients aged 6 to 90y were collected from optometry clinics in fourteen states of Mexico between 2014 and 2015. The refractive errors were classified by the spherical equivalent (SE), as follows: sphere+½ cylinder. Myopia (SE>-0.50 D), hyperopia (SE>+0.50 D), emmetropia (-0.50≤SE≤+0.50), and astigmatism alone (cylinder≥-0.25 D). A negative cylinder was selected as a notation. RESULTS The proportion (95% confidence interval) among all of the subjects was hyperopia 21.0% (20.9-21.0), emmetropia 40.7% (40.5-40.8), myopia 24.8% (24.7-24.9) and astigmatism alone 13.5% (13.4-13.5). Myopia was the most common refractive error and frequency seemed to increase among the young population (10 to 29 years old), however, hyperopia increased among the aging population (40 to 79 years old), and astigmatism alone showed a decreasing trend with age (6 to 90y; from 19.7% to 10.8%). There was a relationship between age and all refractive errors (approximately 60%, aged 50 and older). The proportion of any clinically important refractive error was higher in males (61.2%) than in females (58.3%; P<0.0001). From fourteen states that collected information, the proportion of refractive error showed variability in different geographical areas of Mexico. CONCLUSION Myopia is the most common refractive error in the population studied. This study provides the first data on refractive error in Mexico. Further programs and studies must be developed to address the refractive errors needs of the Mexican population. PMID:28546940

  16. Uncorrected refractive error and presbyopia among junior high school teachers in Jakarta, Indonesia.

    PubMed

    Ehrlich, Joshua R; Laoh, Alex; Kourgialis, Nick; Prasetyanti, Widya; Zakiyah, Rima; Faillace, Silvana; Friedman, David S

    2013-12-01

    To report on the frequency of observed refractive and accommodative errors among junior high school teachers in Jakarta, Indonesia, who participated in a Helen Keller International screening, refraction and spectacle distribution program. A total of 965 teachers from 19 schools were eligible for screening; those with uncorrected distance visual acuity (VA) ≤ 6/12-3 and teachers ≥ 35 years old with uncorrected end-point print size >Jaeger (J) 6 were referred. Autorefraction and subjective refraction were performed for teachers with confirmed decreased VA. Refractive error was considered present if sphere ≤-0.75 diopters (D), sphere ≥+0.25D or cylinder ≤-0.50 D resulted in ≥ 2 lines of improvement in VA. Presbyopia was considered present if an end-point print size >J6 improved by ≥ 1 optotype with the use of a lens ≥+1.00 D. Overall, 866 teachers were screened (89.7% of those eligible) with complete screening data available for 858 (99.0%), among whom 762 failed screening. Distance refraction data were available for 666 of 762 (87.4%) and near refraction data for 520 of 686 (75.8%) teachers who failed screening. Of those screened, 76.2 ± 9.0% of teachers had refractive and/or accommodative error and 57.1 ± 7.6% had uncorrected refractive and/or accommodative error. Overall and uncorrected distance refractive error affected 44.2 ± 3.7% and 36.0 ± 3.6%, respectively; overall and uncorrected presbyopia affected 66.4 ± 8.1% and 41.0 ± 6.6%, respectively. As defined in this program, refractive and accommodative errors were common among teachers in Jakarta.

  17. Correlation of major components of ocular astigmatism in myopic patients.

    PubMed

    Mohammadpour, Mehrdad; Heidari, Zahra; Khabazkhoob, Mehdi; Amouzegar, Afsaneh; Hashemi, Hassan

    2016-02-01

    To investigate the correlation of major components of ocular astigmatism in myopic patients in an academic hospital. This cross-sectional study was conducted on 376 eyes of 188 patients who were referred to Farabi Eye Hospital for refractive surgery. Preoperative examinations including refraction and corneal topography were performed for all candidates to measure refractive and corneal astigmatism. Ocular residual astigmatism was calculated using vector analysis. Pearson's correlation and ANOVA analysis were used to evaluate the strength of the association between different types of astigmatism. Both eyes were defined as cluster and the Generalized Estimating Equations (GEE) analysis were performed. Mean age of 119 women (63.3%) and 69 men (36.7%) was 27.8 ± 5.7 years. Mean refractive error based on spherical equivalent was -3.59 ± 1.95D (range, -0.54 to -10.22D). Mean refractive and corneal astigmatism was 1.97 ± 1.3D and 1.85 ± 1.01D, respectively. Mean amount of ORA was 0.65 ± 0.36D.There was a significant correlation between ORA and refractive astigmatism(r=0.23, p<0.001), corneal and refractive astigmatism (r=0.91, p<0.001) and a weak correlation between ORA and corneal astigmatism (r=0.13, p=0.014). There was a significant correlation between J0 and J45 values of ORA and corneal astigmatism (p<0.001). There is a significant correlation between ORA and refractive astigmatism, refractive and corneal astigmatism and a weak correlation between ORA and corneal astigmatism in refractive surgery candidates. Identifying the type of astigmatism and preoperative measurement of ocular residual astigmatism is highly recommended prior to any refractive surgery, especially in cases with significant astigmatism. Copyright © 2015 Elsevier Ltd. All rights reserved.

  18. Relative peripheral refraction in children: twelve-month changes in eyes with different ametropias.

    PubMed

    Lee, Tsui-Tsui; Cho, Pauline

    2013-05-01

    To determine the peripheral refraction of children with different types of ametropias and to evaluate the relationship between central refractive changes, baseline relative peripheral refraction (RPR) and changes in RPR over a 12-month monitoring period. Cycloplegic central and peripheral refraction were performed biannually on the right eyes of children aged 6-9 for 12 months, using an open-view autorefractor. Peripheral refraction were measured along 10°, 20° and 30° from central fixation in both nasal and temporal fields. Refractive data were transposed into M, J0 and J45 vectors for analyses. RPR was determined by subtracting the central measurement from each peripheral measurement. Hyperopic eyes showed relative peripheral myopia while myopic eyes had relative hyperopia across the central 60° horizontal field at baseline. Emmetropic eyes had relative myopia within but showed relative hyperopia beyond the central 30° field. However, there was no significant correlation between central refractive changes and baseline RPR or between changes in central refraction and RPR over twelve months in any refractive groups. Correlations between changes in PR and central myopic shift were found mainly in the nasal field in different groups. In the subgroup analysis on the initially emmetropic and the initially myopic groups, the subgroups with faster myopic progression did not have significantly different RPR from the subgroups with slower progression. The RPR pattern of the initially emmetropic and the initially myopic groups became more asymmetric at the end of the study period with a larger increase in relative hyperopia in the temporal field. RPR patterns were different among hyperopic, emmetropic and myopic eyes. However, baseline RPR and changes in RPR cannot predict changes in central refraction over time. Our results did not provide evidence to support the hypothesis of RPR as a causative factor for myopic central refractive changes in children. Ophthalmic & Physiological Optics © 2013 The College of Optometrists.

  19. An alternative clinical routine for subjective refraction based on power vectors with trial frames.

    PubMed

    María Revert, Antonia; Conversa, Maria Amparo; Albarrán Diego, César; Micó, Vicente

    2017-01-01

    Subjective refraction determines the final point of refractive error assessment in most clinical environments and its foundations have remained unchanged for decades. The purpose of this paper is to compare the results obtained when monocular subjective refraction is assessed in trial frames by a new clinical procedure based on a pure power vector interpretation with conventional clinical refraction procedures. An alternative clinical routine is described that uses power vector interpretation with implementation in trial frames. Refractive error is determined in terms of: (i) the spherical equivalent (M component), and (ii) a pair of Jackson Crossed Cylinder lenses oriented at 0°/90° (J 0 component) and 45°/135° (J 45 component) for determination of astigmatism. This vector subjective refraction result (VR) is compared separately for right and left eyes of 25 subjects (mean age, 35 ± 4 years) against conventional sphero-cylindrical subjective refraction (RX) using a phoropter. The VR procedure was applied with both conventional tumbling E optotypes (VR1) and modified optotypes with oblique orientation (VR2). Bland-Altman plots and intra-class correlation coefficient showed good agreement between VR, and RX (with coefficient values above 0.82) and anova showed no significant differences in any of the power vector components between RX and VR. VR1 and VR2 procedure results were similar (p ≥ 0.77). The proposed routine determines the three components of refractive error in power vector notation [M, J 0 , J 45 ], with a refraction time similar to the one used in conventional subjective procedures. The proposed routine could be helpful for inexperienced clinicians and for experienced clinicians in those cases where it is difficult to get a valid starting point for conventional RX (irregular corneas, media opacities, etc.) and for refractive situations/places with inadequate refractive facilities/equipment. © 2016 The Authors Ophthalmic & Physiological Optics © 2016 The College of Optometrists.

  20. Prevalence and association of refractive anisometropia with near work habits among young schoolchildren: The evidence from a population-based study

    PubMed Central

    Lee, Chia-Wei; Fang, Shao-You; Huang, Nicole; Hsu, Chih-Chien; Chen, Shing-Yi; Chiu, Allen Wen-Hsiang

    2017-01-01

    Background Lifestyle behaviour may play a role in refractive error among children, but the association between near work habits and refractive anisometropia remains unclear. Methods We estimated the prevalence of refractive anisometropia and examined its association with near work activities among 23,114 children in the Myopia Investigation Study in Taipei who were grade 2 elementary school students at baseline in 2013 and 2014. Baseline data on demographics, medical history, parental history and near work habits were collected by parent-administered questionnaire survey. Refractive status was determined by cycloplegic autorefraction. Refractive anisometropia was defined as the spherical equivalent difference ≥ 1.0 diopter between eyes. Results The prevalence of refractive anisometropia was 5.3% (95% confidence interval [CI], 5.0% to 5.6%). The prevalence and severity of refractive anisometropia increased with both myopic and hyperopic refractive error. Multivariate logistic regression analysis revealed that refractive anisometropia was significantly associated with myopia (odds ratio [OR], 2.98; 95% CI, 2.53–3.51), hyperopia (OR, 2.37; 95% CI, 1.98–2.83), degree of astigmatism (OR, 1.005; 95% CI, 1.005–1.006), amblyopia (OR, 2.54; 95% CI, 2.06–3.12), male gender (OR, 0.88; 95% CI, 0.78–0.99) and senior high school level of maternal education (OR, 0.69; 95% CI, 0.52–0.92). Though anisometropic children were more likely to spend more time on near work (crude OR, 1.15; 95% CI, 1.02–1.29) and to have less eye-to-object distance in doing near work (crude OR, 1.15; 95% CI, 1.01–1.30), these associations became insignificant after additional adjustment for ocular, demographic and parental factors. Conclusions The present study provides large-scale, population-based evidence showing no independent association between refractive anisometropia and near work habits, though myopia is associated with refractive anisometropia. PMID:28273153

  1. PREVALENCE OF UNCORRECTED REFRACTIVE ERRORS IN ADULTS AGED 30 YEARS AND ABOVE IN A RURAL POPULATION IN PAKISTAN.

    PubMed

    Abdullah, Ayesha S; Jadoon, Milhammad Zahid; Akram, Mohammad; Awan, Zahid Hussain; Azam, Mohammad; Safdar, Mohammad; Nigar, Mohammad

    2015-01-01

    Uncorrected refractive errors are a leading cause of visual disability globally. This population-based study was done to estimate the prevalence of uncorrected refractive errors in adults aged 30 years and above of village Pawakah, Khyber Pakhtunkhwa (KPK), Pakistan. It was a cross-sectional survey in which 1000 individuals were included randomly. All the individuals were screened for uncorrected refractive errors and those whose visual acuity (VA) was found to be less than 6/6 were refracted. In whom refraction was found to be unsatisfactory (i.e., a best corrected visual acuity of <6/6) further examination was done to establish the cause for the subnormal vision. A total of 917 subjects participated in the survey (response rate 92%). The prevalence of uncorrected refractive errors was found to be 23.97% among males and 20% among females. The prevalence of visually disabling refractive errors was 6.89% in males and 5.71% in females. The prevalence was seen to increase with age, with maximum prevalence in 51-60 years age group. Hypermetropia (10.14%) was found to be the commonest refractive error followed by Myopia (6.00%) and Astigmatism (5.6%). The prevalence of Presbyopia was 57.5% (60.45% in males and 55.23% in females). Poor affordability was the commonest barrier to the use of spectacles, followed by unawareness. Cataract was the commonest reason for impaired vision after refractive correction. The prevalence of blindness was 1.96% (1.53% in males and 2.28% in females) in this community with cataract as the commonest cause. Despite being the most easily avoidable cause of subnormal vision uncorrected refractive errors still account for a major proportion of the burden of decreased vision in this area. Effective measures for the screening and affordable correction of uncorrected refractive errors need to be incorpora'ted into the health care delivery system.

  2. Prevalence of refractive errors in the Slovak population calculated using the Gullstrand schematic eye model.

    PubMed

    Popov, I; Valašková, J; Štefaničková, J; Krásnik, V

    2017-01-01

    A substantial part of the population suffers from some kind of refractive errors. It is envisaged that their prevalence may change with the development of society. The aim of this study is to determine the prevalence of refractive errors using calculations based on the Gullstrand schematic eye model. We used the Gullstrand schematic eye model to calculate refraction retrospectively. Refraction was presented as the need for glasses correction at a vertex distance of 12 mm. The necessary data was obtained using the optical biometer Lenstar LS900. Data which could not be obtained due to the limitations of the device was substituted by theoretical data from the Gullstrand schematic eye model. Only analyses from the right eyes were presented. The data was interpreted using descriptive statistics, Pearson correlation and t-test. The statistical tests were conducted at a level of significance of 5%. Our sample included 1663 patients (665 male, 998 female) within the age range of 19 to 96 years. Average age was 70.8 ± 9.53 years. Average refraction of the eye was 2.73 ± 2.13D (males 2.49 ± 2.34, females 2.90 ± 2.76). The mean absolute error from emmetropia was 3.01 ± 1.58 (males 2.83 ± 2.95, females 3.25 ± 3.35). 89.06% of the sample was hyperopic, 6.61% was myopic and 4.33% emmetropic. We did not find any correlation between refraction and age. Females were more hyperopic than males. We did not find any statistically significant hypermetopic shift of refraction with age. According to our estimation, the calculations of refractive errors using the Gullstrand schematic eye model showed a significant hypermetropic shift of more than +2D. Our results could be used in future for comparing the prevalence of refractive errors using same methods we used.Key words: refractive errors, refraction, Gullstrand schematic eye model, population, emmetropia.

  3. Prevalence and association of refractive anisometropia with near work habits among young schoolchildren: The evidence from a population-based study.

    PubMed

    Lee, Chia-Wei; Fang, Shao-You; Tsai, Der-Chong; Huang, Nicole; Hsu, Chih-Chien; Chen, Shing-Yi; Chiu, Allen Wen-Hsiang; Liu, Catherine Jui-Ling

    2017-01-01

    Lifestyle behaviour may play a role in refractive error among children, but the association between near work habits and refractive anisometropia remains unclear. We estimated the prevalence of refractive anisometropia and examined its association with near work activities among 23,114 children in the Myopia Investigation Study in Taipei who were grade 2 elementary school students at baseline in 2013 and 2014. Baseline data on demographics, medical history, parental history and near work habits were collected by parent-administered questionnaire survey. Refractive status was determined by cycloplegic autorefraction. Refractive anisometropia was defined as the spherical equivalent difference ≥ 1.0 diopter between eyes. The prevalence of refractive anisometropia was 5.3% (95% confidence interval [CI], 5.0% to 5.6%). The prevalence and severity of refractive anisometropia increased with both myopic and hyperopic refractive error. Multivariate logistic regression analysis revealed that refractive anisometropia was significantly associated with myopia (odds ratio [OR], 2.98; 95% CI, 2.53-3.51), hyperopia (OR, 2.37; 95% CI, 1.98-2.83), degree of astigmatism (OR, 1.005; 95% CI, 1.005-1.006), amblyopia (OR, 2.54; 95% CI, 2.06-3.12), male gender (OR, 0.88; 95% CI, 0.78-0.99) and senior high school level of maternal education (OR, 0.69; 95% CI, 0.52-0.92). Though anisometropic children were more likely to spend more time on near work (crude OR, 1.15; 95% CI, 1.02-1.29) and to have less eye-to-object distance in doing near work (crude OR, 1.15; 95% CI, 1.01-1.30), these associations became insignificant after additional adjustment for ocular, demographic and parental factors. The present study provides large-scale, population-based evidence showing no independent association between refractive anisometropia and near work habits, though myopia is associated with refractive anisometropia.

  4. Shuttle program: Computing atmospheric scale height for refraction corrections

    NASA Technical Reports Server (NTRS)

    Lear, W. M.

    1980-01-01

    Methods for computing the atmospheric scale height to determine radio wave refraction were investigated for different atmospheres, and different angles of elevation. Tables of refractivity versus altitude are included. The equations used to compute the refraction corrections are given. It is concluded that very accurate corrections are determined with the assumption of an exponential atmosphere.

  5. Causality, Nonlocality, and Negative Refraction.

    PubMed

    Forcella, Davide; Prada, Claire; Carminati, Rémi

    2017-03-31

    The importance of spatial nonlocality in the description of negative refraction in electromagnetic materials has been put forward recently. We develop a theory of negative refraction in homogeneous and isotropic media, based on first principles, and that includes nonlocality in its full generality. The theory shows that both dissipation and spatial nonlocality are necessary conditions for the existence of negative refraction. It also provides a sufficient condition in materials with weak spatial nonlocality. These fundamental results should have broad implications in the theoretical and practical analyses of negative refraction of electromagnetic and other kinds of waves.

  6. Dark solitons at nonlinear interfaces.

    PubMed

    Sánchez-Curto, Julio; Chamorro-Posada, Pedro; McDonald, Graham S

    2010-05-01

    The refraction of dark solitons at a planar boundary separating two defocusing Kerr media is simulated and analyzed, for the first time (to our knowledge). Analysis is based on the nonlinear Helmholtz equation and is thus valid for any angle of incidence. A new law, governing refraction of black solitons, is combined with one describing bright soliton refraction to yield a generalized Snell's law whose validity is verified numerically. The complexity of gray soliton refraction is also analyzed, and illustrated by a change from external to internal refraction on varying the soliton contrast parameter.

  7. Effects of horizontal refractivity gradients on the accuracy of laser ranging to satellites

    NASA Technical Reports Server (NTRS)

    Gardner, C. S.

    1976-01-01

    Numerous formulas have been developed to partially correct laser ranging data for the effects of atmospheric refraction. All the formulas assume the atmospheric refractivity profile is spherically symmetric. The effects of horizontal refractivity gradients are investigated by ray tracing through spherically symmetric and three-dimensional refractivity profiles. The profiles are constructed from radiosonde data. The results indicate that the horizontal gradients introduce an rms error of approximately 3 cm when the satellite is near 10 deg elevation. The error decreases to a few millimeters near zenith.

  8. Long period grating refractive-index sensor: optimal design for single wavelength interrogation.

    PubMed

    Kapoor, Amita; Sharma, Enakshi K

    2009-11-01

    We report the design criteria for the use of long period gratings (LPGs) as refractive-index sensors with output power at a single interrogating wavelength as the measurement parameter. The design gives maximum sensitivity in a given refractive-index range when the interrogating wavelength is fixed. Use of the design criteria is illustrated by the design of refractive-index sensors for specific application to refractive-index variation of a sugar solution with a concentration and detection of mole fraction of xylene in heptane (paraffin).

  9. Roughened glass slides and a spectrophotometer for the detection of the wavelength-dependent refractive index of transparent liquids.

    PubMed

    Niskanen, Ilpo; Räty, Jukka; Myllylä, Risto; Sutinen, Veijo; Matsuda, Kiyofumi; Homma, Kazuhiro; Silfsten, Pertti; Peiponen, Kai-Erik

    2012-07-01

    We describe a method to determine the wavelength-dependent refractive index of liquids by measurement of light transmittance with a spectrophotometer. The method is based on using roughened glass slides with different a priori known refractive indices and immersing the slides into the transparent liquid with unknown refractive index. Using the dispersion data on the glass material it is possible to find the index match between the liquid and the glass slide, and hence the refractive index of the liquid.

  10. Compact eccentric long period grating with improved sensitivity in low refractive index region.

    PubMed

    Shen, Fangcheng; Zhou, Kaiming; Gordon, Neil; Zhang, Lin; Shu, Xuewen

    2017-07-10

    We demonstrate a compact eccentric long period grating with enhanced sensitivity in low refractive index region. With a period designed at 15 µm for coupling light to high order cladding modes, the grating is more sensitive to surrounding refractive index in low refractive index region. The intrinsically low coupling coefficients for those high order cladding modes are significantly improved with the eccentric localized inscription induced by the femtosecond laser. The fabricated grating is compact with a length of 4.05 mm, and exhibits an average sensitivity of ~505 nm/RIU in low refractive index region (1.3328-1.3544). The proposed principle can also work in other refractive index region with a proper choice of the resonant cladding modes.

  11. Decoupling the refractive index from the electrical properties of transparent conducting oxides via periodic superlattices.

    PubMed

    Caffrey, David; Norton, Emma; Coileáin, Cormac Ó; Smith, Christopher M; Bulfin, Brendan; Farrell, Leo; Shvets, Igor V; Fleischer, Karsten

    2016-09-13

    We demonstrate an alternative approach to tuning the refractive index of materials. Current methodologies for tuning the refractive index of a material often result in undesirable changes to the structural or optoelectronic properties. By artificially layering a transparent conducting oxide with a lower refractive index material the overall film retains a desirable conductivity and mobility while acting optically as an effective medium with a modified refractive index. Calculations indicate that, with our refractive index change of 0.2, a significant reduction of reflective losses could be obtained by the utilisation of these structures in optoelectronic devices. Beyond this, periodic superlattice structures present a solution to decouple physical properties where the underlying electronic interaction is governed by different length scales.

  12. Reflection based Extraordinary Optical Transmission Fiber Optic Probe for Refractive Index Sensing.

    PubMed

    Lan, Xinwei; Cheng, Baokai; Yang, Qingbo; Huang, Jie; Wang, Hanzheng; Ma, Yinfa; Shi, Honglan; Xiao, Hai

    2014-03-31

    Fiber optic probes for chemical sensing based on the extraordinary optical transmission (EOT) phenomenon are designed and fabricated by perforating subwavelength hole arrays on the gold film coated optical fiber endface. The device exhibits a red shift in response to the surrounding refractive index increases with high sensitivity, enabling a reflection-based refractive index sensor with a compact and simple configuration. By choosing the period of hole arrays, the sensor can be designed to operate in the near infrared telecommunication wavelength range, where the abundant source and detectors are available for easy instrumentation. The new sensor probe is demonstrated for refractive index measurement using refractive index matching fluids. The sensitivity reaches 573 nm/RIU in the 1.333~1.430 refractive index range.

  13. Refraction of Radio Waves on the Radio-Occultation Satellite-to-Satellite Paths as a Characteristic of the Atmospheric State

    NASA Astrophysics Data System (ADS)

    Matyugov, S. S.; Yakovlev, O. I.; Pavelyev, A. G.; Pavelyev, A. A.; Anufriev, V. A.

    2017-10-01

    We present the results of analyzing the radio-wave refractive characteristics measured on the radio-occultation paths between the GPS navigation satellites and the FORMOSAT-3 research satellites in the central region of the European territory of Russia in 2007-2013. The diurnal, seasonal, and annual variations in the refraction angle at altitudes of 2 to 25 km are discussed. It is shown that the refraction angle can be used as an independent characteristic of the atmospheric state and its long-term variation trends. Diurnal and nocturnal variations in the refraction angle in the winter and summer seasons are analyzed. Trends in the atmospheric refraction variations over seven years are discussed.

  14. Sensing dynamic cytoplasm refractive index changes of adherent cells with quantitative phase microscopy using incorporated microspheres as optical probes.

    PubMed

    Przibilla, Sabine; Dartmann, Sebastian; Vollmer, Angelika; Ketelhut, Steffi; Greve, Burkhard; von Bally, Gert; Kemper, Björn

    2012-09-01

    The intracellular refractive index is an important parameter that describes the optical density of the cytoplasm and the concentration of the intracellular solutes. The refractive index of adherently grown cells is difficult to access. We present a method in which silica microspheres in living cells are used to determine the cytoplasm refractive index with quantitative phase microscopy. The reliability of our approach for refractive index retrieval is shown by data from a comparative study on osmotically stimulated adherent and suspended human pancreatic tumor cells. Results from adherent human fibro sarcoma cells demonstrate the capability of the method for sensing of dynamic refractive index changes and its usage with microfluidics.

  15. Refractive index dependence of L3 photonic crystal nano-cavities.

    PubMed

    Adawi, A M; Chalcraft, A R; Whittaker, D M; Lidzey, D G

    2007-10-29

    We model the optical properties of L3 photonic crystal nano-cavities as a function of the photonic crystal membrane refractive index n using a guided mode expansion method. Band structure calculations revealed that a TE-like full band-gap exists for materials of refractive index as low as 1.6. The Q-factor of such cavities showed a super-linear increase with refractive index. By adjusting the relative position of the cavity side holes, the Q-factor was optimised as a function of the photonic crystal membrane refractive index n over the range 1.6 to 3.4. Q-factors in the range 3000-8000 were predicted from absorption free materials in the visible range with refractive index between 2.45 and 2.8.

  16. Refractometers for different refractive index range by surface plasmon resonance sensors in multimode optical fibers with different metals

    NASA Astrophysics Data System (ADS)

    Zuppella, P.; Corso, Alain J.; Pelizzo, Maria G.; Cennamo, N.; Zeni, L.

    2016-09-01

    We have realized a plasmonic sensor based on Au/Pd metal bilayer in a multimode plastic optical fiber. This metal bilayer, based on a metal with high imaginary part of the refractive index and gold, shows interesting properties in terms of sensitivity and performances, in different refractive index ranges. The development of highly sensitive platforms for high refractive index detection (higher than 1.38) is interesting for chemical applications based on molecularly imprinted polymer as receptors, while the aqueous medium is the refractive index range of biosensors based on bio-receptors. In this work we have presented an Au/Pd metal bilayer optimized for 1.38-1.42 refractive index range.

  17. Measurement and design of refractive corrections using ultrafast laser-induced intra-tissue refractive index shaping in live cats

    NASA Astrophysics Data System (ADS)

    Brooks, Daniel R.; Wozniak, Kaitlin T.; Knox, Wayne; Ellis, Jonathan D.; Huxlin, Krystel R.

    2018-02-01

    Intra-Tissue Refractive Index Shaping (IRIS) uses a 405 nm femtosecond laser focused into the stromal region of the cornea to induce a local refractive index change through multiphoton absorption. This refractive index change can be tailored through scanning of the focal region and variations in laser power to create refractive structures, such as gradient index lenses for visual refractive correction. Previously, IRIS was used to create 2.5 mm wide, square, -1 D cylindrical refractive structures in living cats. In the present work, we first wrote 400 μm wide bars of refractive index change at varying powers in enucleated cat globes using a custom flexure-based scanning system. The cornea and surrounding sclera were then removed and mounted into a wet cell. The induced optical phase change was measured with a Mach- Zehnder Interferometer (MZI), and appeared as fringe displacement, whose magnitude was proportional to the refractive index change. The interferograms produced by the MZI were analyzed with a Fourier Transform based algorithm in order to extract the phase change. This provided a phase change versus laser power calibration, which was then used to design the scanning and laser power distribution required to create -1.5 D cylindrical Fresnel lenses in cat cornea covering an area 6 mm in diameter. This prescription was inscribed into the corneas of one eye each of two living cats, under surgical anesthesia. It was then verified in vivo by contrasting wavefront aberration measurements collected pre- IRIS with those obtained over six months post-IRIS using a Shack-Hartmann wavefront sensor.

  18. Relative Proportion Of Different Types Of Refractive Errors In Subjects Seeking Laser Vision Correction.

    PubMed

    Althomali, Talal A

    2018-01-01

    Refractive errors are a form of optical defect affecting more than 2.3 billion people worldwide. As refractive errors are a major contributor of mild to moderate vision impairment, assessment of their relative proportion would be helpful in the strategic planning of health programs. To determine the pattern of the relative proportion of types of refractive errors among the adult candidates seeking laser assisted refractive correction in a private clinic setting in Saudi Arabia. The clinical charts of 687 patients (1374 eyes) with mean age 27.6 ± 7.5 years who desired laser vision correction and underwent a pre-LASIK work-up were reviewed retrospectively. Refractive errors were classified as myopia, hyperopia and astigmatism. Manifest refraction spherical equivalent (MRSE) was applied to define refractive errors. Distribution percentage of different types of refractive errors; myopia, hyperopia and astigmatism. The mean spherical equivalent for 1374 eyes was -3.11 ± 2.88 D. Of the total 1374 eyes, 91.8% (n = 1262) eyes had myopia, 4.7% (n = 65) eyes had hyperopia and 3.4% (n = 47) had emmetropia with astigmatism. Distribution percentage of astigmatism (cylinder error of ≥ 0.50 D) was 78.5% (1078/1374 eyes); of which % 69.1% (994/1374) had low to moderate astigmatism and 9.4% (129/1374) had high astigmatism. Of the adult candidates seeking laser refractive correction in a private setting in Saudi Arabia, myopia represented greatest burden with more than 90% myopic eyes, compared to hyperopia in nearly 5% eyes. Astigmatism was present in more than 78% eyes.

  19. Indications for and outcomes of tertiary referrals in refractive surgery.

    PubMed

    Patryn, Eliza K; Vrijman, Violette; Nieuwendaal, Carla P; van der Meulen, Ivanka J E; Mourits, Maarten P; Lapid-Gortzak, Ruth

    2014-01-01

    To review the spectrum of disease, symptomatology, and management offered to patients referred for a second opinion after refractive surgery. A prospective cohort study was done on all patients referred from October 1, 2006, to September 30, 2011, to a tertiary eye clinic after refractive surgery of any kind (ie, corneal laser surgery, conductive keratoplasty, radial keratotomy, phakic implants, refractive lens exchanges, or any combination thereof). Data analysis was performed on all demographic and clinical aspects of this cohort, including the initial complaint, type of referral, number of complaints, procedure previously performed, diagnosis at our center, type of advice given, and rate and type of surgical intervention. One hundred thirty-one eyes (69 patients) were included. Corneal refractive surgery was performed in 82% (108 eyes), and 11% (14 eyes) were seen after phakic intraocular lens (PIOL) implantation and 7% (9 eyes) after refractive lens exchange. The most common diagnoses were tear film dysfunction (30 eyes, 23%), residual refractive error (25 eyes, 19%), and cataract (20 eyes, 15%). Most patients (42 patients, 61%) were treated conservatively. In 27 patients (39%), 36 eyes (28%) were managed surgically. Severe visual loss was seen in 1 eye. No major problems were found in most second opinions after refractive surgery referral. Dry eyes, small residual refractive error, or higher-order aberrations were the most common complaints. Surgical intervention was needed in 36 eyes (28%), almost half of which were cataract extractions. Severe visual loss was seen in 1 eye with a PIOL. There was no incidence of severe visual loss in keratorefractive and refractive lens exchange procedures. Copyright 2014, SLACK Incorporated.

  20. Risk factors for refractive errors in primary school children (6-12 years old) in Nakhon Pathom Province.

    PubMed

    Yingyong, Penpimol

    2010-11-01

    Refractive error is one of the leading causes of visual impairment in children. An analysis of risk factors for refractive error is required to reduce and prevent this common eye disease. To identify the risk factors associated with refractive errors in primary school children (6-12 year old) in Nakhon Pathom province. A population-based cross-sectional analytic study was conducted between October 2008 and September 2009 in Nakhon Pathom. Refractive error, parental refractive status, and hours per week of near activities (studying, reading books, watching television, playing with video games, or working on the computer) were assessed in 377 children who participated in this study. The most common type of refractive error in primary school children was myopia. Myopic children were more likely to have parents with myopia. Children with myopia spend more time at near activities. The multivariate odds ratio (95% confidence interval)for two myopic parents was 6.37 (2.26-17.78) and for each diopter-hour per week of near work was 1.019 (1.005-1.033). Multivariate logistic regression models show no confounding effects between parental myopia and near work suggesting that each factor has an independent association with myopia. Statistical analysis by logistic regression revealed that family history of refractive error and hours of near-work were significantly associated with refractive error in primary school children.

  1. Method and apparatus for determining peak temperature along an optical fiber

    DOEpatents

    Fox, Richard J.

    1985-01-01

    The invention relates to a new method and new apparatus for determining the hottest temperature or the coldest temperature prevailing along the length of an optical-fiber light guide. The invention is conducted with an optical fiber capable of supporting multidiode propagation of light and comprising a core, a cladding, and a jacket. The core is selected to have (1) a higher refractive index than the core and the cladding and (2) a relatively high negative temperature coefficient of refractive index. A light beam capable of establishing substantially single-mode propagation in the core is launched into an end thereof at an angle to the axis. The angle is increased to effect the onset of light refraction from the core into the cladding. The value of the launch angle corresponding to the onset is determined and then used to establish the refractive index of the core corresponding to the onset angle. The maximum temperature prevailing along the fiber then is determined from the (1) refractive index so determined and (2) the temperature coefficient of refractive index for the core. The invention is based on the finding that the launch angle corresponding to the onset of refraction into the cladding is uniquely determined by the maximum value of the ratio of the core refractive index to the cladding refractive index, which maximum occurs at the hottest point along the fiber.

  2. Modified Kramers-Kronig relations and sum rules for meromorphic total refractive index

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Peiponen, Kai-Erik; Saarinen, Jarkko J.; Vartiainen, Erik M.

    2003-08-01

    Modified Kramers-Kronig relations and corresponding sum rules are shown to hold for the total refractive index that can be presented as a sum of complex linear and nonlinear refractive indices, respectively. It is suggested that a self-action process, involving the degenerate third-order nonlinear susceptibility, can yield a negative total refractive index at some spectral range.

  3. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hidayat, Arif, E-mail: arif.hidayat.fmipa@um.ac.id; Latifah, Eny; Kurniati, Diana

    This study investigated the influence of refraction index strength on the light propagation in refraction index-varied dielectric material. This dielectric material served as photonic lattice. The behavior of light propagation influenced by variation of refraction index in photonic lattice was investigated. Modes of the guiding light were determined numerically using squared-operator iteration method. It was found that the greater the strength of refraction index, the smaller the guiding modes.

  4. [Comparison of refraction with or without cycloplegia using Retinomax® or Plusoptix® devices].

    PubMed

    Bui Quoc, E; Guilmin Crepon, S; Tinguely, S; Lavallee, G; Busquet, G; Angot, M; Vera, L

    2017-03-01

    To evaluate the refraction in children measured with Plusoptix ® without cycloplegia vs. Retinomax ® apparatus with cycloplegia. Measure of refraction with Plusoptix ® in children>1year old referred for systematic vision screening, then measurement after cycloplegia with cyclopentolate by the Retinomax ® device. Thirty-three children were included, i.e. 66eyes. Mean age was 40.7months (minimum 12; maximum 114). The Spearman correlation coefficient for the spherical equivalent was 0.52 (Plusoptix ® vs. Retinomax ® comparison; P<0.0001=moderate correlation). The Spearman correlation coefficient was 0.73 for astigmatism (Plusoptix ® vs. Retinomax ® comparison; P<0.0001=strong correlation). The Plusoptix ® sensitivity for measurement of refraction was 57%, 43% and 43% respectively for spherical equivalent, sphere and astigmatism. The correlation of astigmatism values is strong, whereas the correlation of sphere values is moderate. Plusoptix ® seems to be unable to measure the exact refraction, because there is too large a dispersion of refraction measurements with Plusoptix ® , compared to the exact refraction measured with the Retinomax ® . Moreover, the sensitivity of Plusoptix ® is low. Cycloplegic refraction remains indispensable in children. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  5. Uncorrected refractive errors.

    PubMed

    Naidoo, Kovin S; Jaggernath, Jyoti

    2012-01-01

    Global estimates indicate that more than 2.3 billion people in the world suffer from poor vision due to refractive error; of which 670 million people are considered visually impaired because they do not have access to corrective treatment. Refractive errors, if uncorrected, results in an impaired quality of life for millions of people worldwide, irrespective of their age, sex and ethnicity. Over the past decade, a series of studies using a survey methodology, referred to as Refractive Error Study in Children (RESC), were performed in populations with different ethnic origins and cultural settings. These studies confirmed that the prevalence of uncorrected refractive errors is considerably high for children in low-and-middle-income countries. Furthermore, uncorrected refractive error has been noted to have extensive social and economic impacts, such as limiting educational and employment opportunities of economically active persons, healthy individuals and communities. The key public health challenges presented by uncorrected refractive errors, the leading cause of vision impairment across the world, require urgent attention. To address these issues, it is critical to focus on the development of human resources and sustainable methods of service delivery. This paper discusses three core pillars to addressing the challenges posed by uncorrected refractive errors: Human Resource (HR) Development, Service Development and Social Entrepreneurship.

  6. Cell refractive index for cell biology and disease diagnosis: past, present and future.

    PubMed

    Liu, P Y; Chin, L K; Ser, W; Chen, H F; Hsieh, C-M; Lee, C-H; Sung, K-B; Ayi, T C; Yap, P H; Liedberg, B; Wang, K; Bourouina, T; Leprince-Wang, Y

    2016-02-21

    Cell refractive index is a key biophysical parameter, which has been extensively studied. It is correlated with other cell biophysical properties including mechanical, electrical and optical properties, and not only represents the intracellular mass and concentration of a cell, but also provides important insight for various biological models. Measurement techniques developed earlier only measure the effective refractive index of a cell or a cell suspension, providing only limited information on cell refractive index and hence hindering its in-depth analysis and correlation. Recently, the emergence of microfluidic, photonic and imaging technologies has enabled the manipulation of a single cell and the 3D refractive index of a single cell down to sub-micron resolution, providing powerful tools to study cells based on refractive index. In this review, we provide an overview of cell refractive index models and measurement techniques including microfluidic chip-based techniques for the last 50 years, present the applications and significance of cell refractive index in cell biology, hematology, and pathology, and discuss future research trends in the field, including 3D imaging methods, integration with microfluidics and potential applications in new and breakthrough research areas.

  7. A clinic-based study of refractive errors, strabismus, and amblyopia in pediatric age-group.

    PubMed

    Al-Tamimi, Elham R; Shakeel, Ayisha; Yassin, Sanaa A; Ali, Syed I; Khan, Umar A

    2015-01-01

    The purpose of this cross-sectional observational study was to determine the distribution and patterns of refractive errors, strabismus, and amblyopia in children seen at a pediatric eye care. The study was conducted in a Private Hospital in Dammam, Kingdom of Saudi Arabia, from March to July 2013. During this period, a total of 1350 children, aged 1-15 years were seen at this Center's Pediatric Ophthalmology Unit. All the children underwent complete ophthalmic examination with cycloplegic refraction. Refractive errors accounted for 44.4% of the cases, the predominant refractive error being hypermetropia which represented 83%. Strabismus and amblyopia were present in 38% and 9.1% of children, respectively. In this clinic-based study, the focus was on the frequency of refractive errors, strabismus, and amblyopia which were considerably high. Hypermetropia was the predominant refractive error in contrast to other studies in which myopia was more common. This could be attributed to the criteria for sample selection since it was clinic-based rather than a population-based study. However, it is important to promote public education on the significance of early detection of refractive errors, and have periodic screening in schools.

  8. Refractive errors and schizophrenia.

    PubMed

    Caspi, Asaf; Vishne, Tali; Reichenberg, Abraham; Weiser, Mark; Dishon, Ayelet; Lubin, Gadi; Shmushkevitz, Motti; Mandel, Yossi; Noy, Shlomo; Davidson, Michael

    2009-02-01

    Refractive errors (myopia, hyperopia and amblyopia), like schizophrenia, have a strong genetic cause, and dopamine has been proposed as a potential mediator in their pathophysiology. The present study explored the association between refractive errors in adolescence and schizophrenia, and the potential familiality of this association. The Israeli Draft Board carries a mandatory standardized visual accuracy assessment. 678,674 males consecutively assessed by the Draft Board and found to be psychiatrically healthy at age 17 were followed for psychiatric hospitalization with schizophrenia using the Israeli National Psychiatric Hospitalization Case Registry. Sib-ships were also identified within the cohort. There was a negative association between refractive errors and later hospitalization for schizophrenia. Future male schizophrenia patients were two times less likely to have refractive errors compared with never-hospitalized individuals, controlling for intelligence, years of education and socioeconomic status [adjusted Hazard Ratio=.55; 95% confidence interval .35-.85]. The non-schizophrenic male siblings of schizophrenia patients also had lower prevalence of refractive errors compared to never-hospitalized individuals. Presence of refractive errors in adolescence is related to lower risk for schizophrenia. The familiality of this association suggests that refractive errors may be associated with the genetic liability to schizophrenia.

  9. Ultraviolet refractometry using field-based light scattering spectroscopy

    PubMed Central

    Fu, Dan; Choi, Wonshik; Sung, Yongjin; Oh, Seungeun; Yaqoob, Zahid; Park, YongKeun; Dasari, Ramachandra R.; Feld, Michael S.

    2010-01-01

    Accurate refractive index measurement in the deep ultraviolet (UV) range is important for the separate quantification of biomolecules such as proteins and DNA in biology. This task is demanding and has not been fully exploited so far. Here we report a new method of measuring refractive index using field-based light scattering spectroscopy, which is applicable to any wavelength range and suitable for both solutions and homogenous objects with well-defined shape such as microspheres. The angular scattering distribution of single microspheres immersed in homogeneous media is measured over the wavelength range 260 to 315 nm using quantitative phase microscopy. By least square fitting the observed scattering distribution with Mie scattering theory, the refractive index of either the sphere or the immersion medium can be determined provided that one is known a priori. Using this method, we have measured the refractive index dispersion of SiO2 spheres and bovine serum albumin (BSA) solutions in the deep UV region. Specific refractive index increments of BSA are also extracted. Typical accuracy of the present refractive index technique is ≤0.003. The precision of refractive index measurements is ≤0.002 and that of specific refractive index increment determination is ≤0.01 mL/g. PMID:20372622

  10. Acoustic computer tomographic pyrometry for two-dimensional measurement of gases taking into account the effect of refraction of sound wave paths

    NASA Astrophysics Data System (ADS)

    Lu, J.; Wakai, K.; Takahashi, S.; Shimizu, S.

    2000-06-01

    The algorithm which takes into account the effect of refraction of sound wave paths for acoustic computer tomography (CT) is developed. Incorporating the algorithm of refraction into ordinary CT algorithms which are based on Fourier transformation is very difficult. In this paper, the least-squares method, which is capable of considering the refraction effect, is employed to reconstruct the two-dimensional temperature distribution. The refraction effect is solved by writing a set of differential equations which is derived from Fermat's theorem and the calculus of variations. It is impossible to carry out refraction analysis and the reconstruction of temperature distribution simultaneously, so the problem is solved using the iteration method. The measurement field is assumed to take the shape of a circle and 16 speakers, also serving as the receivers, are set around it isometrically. The algorithm is checked through computer simulation with various kinds of temperature distributions. It is shown that the present method which takes into account the algorithm of the refraction effect can reconstruct temperature distributions with much greater accuracy than can methods which do not include the refraction effect.

  11. Refraction-compensated motion tracking of unrestrained small animals in positron emission tomography.

    PubMed

    Kyme, Andre; Meikle, Steven; Baldock, Clive; Fulton, Roger

    2012-08-01

    Motion-compensated radiotracer imaging of fully conscious rodents represents an important paradigm shift for preclinical investigations. In such studies, if motion tracking is performed through a transparent enclosure containing the awake animal, light refraction at the interface will introduce errors in stereo pose estimation. We have performed a thorough investigation of how this impacts the accuracy of pose estimates and the resulting motion correction, and developed an efficient method to predict and correct for refraction-based error. The refraction model underlying this study was validated using a state-of-the-art motion tracking system. Refraction-based error was shown to be dependent on tracking marker size, working distance, and interface thickness and tilt. Correcting for refraction error improved the spatial resolution and quantitative accuracy of motion-corrected positron emission tomography images. Since the methods are general, they may also be useful in other contexts where data are corrupted by refraction effects. Crown Copyright © 2012. Published by Elsevier B.V. All rights reserved.

  12. Refraction index sensor based on phase resonances in a subwavelength structure with double period.

    PubMed

    Skigin, Diana C; Lester, Marcelo

    2016-10-01

    In this paper, we numerically demonstrate a refraction index sensor based on phase resonance excitation in a subwavelength-slit structure with a double period. The sensor consists of a metal layer with subwavelength slots arranged in a bi-periodic form, separated from a high refraction index medium. Between the metallic structure and the incident medium, a dielectric waveguide is formed whose refraction index is going to be determined. Variations in the refraction index of the waveguide are detected as shifts in the peaks of transmitted intensity originated by resonant modes supported by the compound metallic structure. At normal incidence, the spectral position of these resonant peaks exhibits a linear or a quadratic dependence with the refraction index, which permits us to obtain the unknown refraction index value with a high precision for a wide range of wavelengths. Since the operating principle of the sensor is due to the morphological resonances of the slits' structure, this device can be scaled to operate in different wavelength ranges while keeping similar characteristics.

  13. Negative refraction in molybdenum disulfide.

    PubMed

    Wang, Wenhui; Cui, Xudong; Yang, Erchan; Fan, Quanping; Xiang, Bin

    2015-08-24

    Recently, negative refractions have been demonstrated in uniaxial crystals with no necessary of negative permittivity and permeability. However, the small anisotropy parameterγin the uniaxial crystals limits the negative refraction occurrence only in a small range of the incident light angle, retarding its practical applications. In this paper, we report negative refraction induced by a pronounced anisotropic behavior in the bulk MoS(2). Using the first-principles, the dielectric function and refractive index calculations confirm a uniaxial trait of MoS(2) with a calculated anisotropy parameterγlarger than 2.5 in the entire range of visible wavelength. The critical incident angle to trigger a negative refraction in the bulk MoS(2) is calculated up to 90°. The finite-difference time-domain simulations prove that the incident light with a density of 59.5% can be negatively refracted in a MoS(2) slab with a thickness of 0.1 µm. Our results open up a new pathway for MoS(2)-like materials to a novel field of optical integration.

  14. A single-image method for x-ray refractive index CT.

    PubMed

    Mittone, A; Gasilov, S; Brun, E; Bravin, A; Coan, P

    2015-05-07

    X-ray refraction-based computer tomography imaging is a well-established method for nondestructive investigations of various objects. In order to perform the 3D reconstruction of the index of refraction, two or more raw computed tomography phase-contrast images are usually acquired and combined to retrieve the refraction map (i.e. differential phase) signal within the sample. We suggest an approximate method to extract the refraction signal, which uses a single raw phase-contrast image. This method, here applied to analyzer-based phase-contrast imaging, is employed to retrieve the index of refraction map of a biological sample. The achieved accuracy in distinguishing the different tissues is comparable with the non-approximated approach. The suggested procedure can be used for precise refraction computer tomography with the advantage of a reduction of at least a factor of two of both the acquisition time and the dose delivered to the sample with respect to any of the other algorithms in the literature.

  15. Effect of refractive error on temperament and character properties.

    PubMed

    Kalkan Akcay, Emine; Canan, Fatih; Simavli, Huseyin; Dal, Derya; Yalniz, Hacer; Ugurlu, Nagihan; Gecici, Omer; Cagil, Nurullah

    2015-01-01

    To determine the effect of refractive error on temperament and character properties using Cloninger's psychobiological model of personality. Using the Temperament and Character Inventory (TCI), the temperament and character profiles of 41 participants with refractive errors (17 with myopia, 12 with hyperopia, and 12 with myopic astigmatism) were compared to those of 30 healthy control participants. Here, temperament comprised the traits of novelty seeking, harm-avoidance, and reward dependence, while character comprised traits of self-directedness, cooperativeness, and self-transcendence. Participants with refractive error showed significantly lower scores on purposefulness, cooperativeness, empathy, helpfulness, and compassion (P<0.05, P<0.01, P<0.05, P<0.05, and P<0.01, respectively). Refractive error might have a negative influence on some character traits, and different types of refractive error might have different temperament and character properties. These personality traits may be implicated in the onset and/or perpetuation of refractive errors and may be a productive focus for psychotherapy.

  16. Terahertz metasurfaces with a high refractive index enhanced by the strong nearest neighbor coupling.

    PubMed

    Tan, Siyu; Yan, Fengping; Singh, Leena; Cao, Wei; Xu, Ningning; Hu, Xiang; Singh, Ranjan; Wang, Mingwei; Zhang, Weili

    2015-11-02

    The realization of high refractive index is of significant interest in optical imaging with enhanced resolution. Strongly coupled subwavelength resonators were proposed and demonstrated at both optical and terahertz frequencies to enhance the refractive index due to large induced dipole moment in meta-atoms. Here, we report an alternative design for flexible free-standing terahertz metasurface in the strong coupling regime where we experimentally achieve a peak refractive index value of 14.36. We also investigate the impact of the nearest neighbor coupling in the form of frequency tuning and enhancement of the peak refractive index. We provide an analytical circuit model to explain the impact of geometrical parameters and coupling on the effective refractive index of the metasurface. The proposed meta-atom structure enables tailoring of the peak refractive index based on nearest neighbor coupling and this property offers tremendous design flexibility for transformation optics and other index-gradient devices at terahertz frequencies.

  17. Demonstration of versatile whispering-gallery micro-lasers for remote refractive index sensing.

    PubMed

    Wan, Lei; Chandrahalim, Hengky; Zhou, Jian; Li, Zhaohui; Chen, Cong; Cho, Sangha; Zhang, Hui; Mei, Ting; Tian, Huiping; Oki, Yuji; Nishimura, Naoya; Fan, Xudong; Guo, L Jay

    2018-03-05

    We developed chip-scale remote refractive index sensors based on Rhodamine 6G (R6G)-doped polymer micro-ring lasers. The chemical, temperature, and mechanical sturdiness of the fused-silica host guaranteed a flexible deployment of dye-doped polymers for refractive index sensing. The introduction of the dye as gain medium demonstrated the feasibility of remote sensing based on the free-space optics measurement setup. Compared to the R6G-doped TZ-001, the lasing behavior of R6G-doped SU-8 polymer micro-ring laser under an aqueous environment had a narrower spectrum linewidth, producing the minimum detectable refractive index change of 4 × 10 -4 RIU. The maximum bulk refractive index sensitivity (BRIS) of 75 nm/RIU was obtained for SU-8 laser-based refractive index sensors. The economical, rapid, and simple realization of polymeric micro-scale whispering-gallery-mode (WGM) laser-based refractive index sensors will further expand pathways of static and dynamic remote environmental, chemical, biological, and bio-chemical sensing.

  18. Design of a compact and high sensitive refractive index sensor base on metal-insulator-metal plasmonic Bragg grating.

    PubMed

    Binfeng, Yun; Guohua, Hu; Ruohu, Zhang; Yiping, Cui

    2014-11-17

    A nanometric and high sensitive refractive index sensor based on the metal-insulator-metal plasmonic Bragg grating is proposed. The wavelength encoded sensing characteristics of the refractive index sensor were investigated by analyzing its transmission spectrum. The numerical results show that a good linear relationship between the Bragg wavelength and the refractive index of the sensing material can be obtained, which is in accordance with the analytical results very well. A high refractive index sensitivity of 1,488 nm/RIU around Bragg resonance wavelength of 1,550 nm was obtained. Besides, the simulation results show that the sensitivity is depended on the Bragg resonance wavelength and the longer the Bragg resonance wavelength, the higher sensitivity can be obtained. Furthermore, the figure of merit of the refractive index sensor can be greatly increased by introducing a nano-cavity in the proposed plasmonic Bragg grating structure. This work pave the way for high sensitive nanometric refractive index sensor design and application.

  19. Phase synchronization between tropospheric radio refractivity and rainfall amount in a tropical region

    NASA Astrophysics Data System (ADS)

    Fuwape, Ibiyinka A.; Ogunjo, Samuel T.; Dada, Joseph B.; Ashidi, Gabriel A.; Emmanuel, Israel

    2016-11-01

    This study investigated linear and nonlinear relationship between the amount of rainfall and radio refractivity in a tropical country, Nigeria using forty seven locations scattered across the country. Correlation and Phase synchronization measures were used for the linear and nonlinear relationship respectively. Weak correlation and phase synchronization was observed between seasonal mean rainfall amount and radio refractivity while strong phase synchronization was found for the detrended data suggesting similar underlying dynamics between rainfall amount and radio refractivity. Causation between rainfall and radio refractivity in a tropical location was studied using Granger causality test. In most of the Southern locations, rainfall was found to Granger cause radio refractivity. Furthermore, it was observed that there is strong correlation between mean rainfall amount and the phase synchronization index over Nigeria. Coupling between rainfall and radio refractivity has been found to be due to water vapour in the atmosphere. Frequency planning and budgeting for microwave propagation during periods of high rainfall should take into consideration this nonlinear relationship.

  20. The GEnes in Myopia (GEM) study in understanding the aetiology of refractive errors.

    PubMed

    Baird, Paul N; Schäche, Maria; Dirani, Mohamed

    2010-11-01

    Refractive errors represent the leading cause of correctable vision impairment and blindness in the world with an estimated 2 billion people affected. Refractive error refers to a group of refractive conditions including hypermetropia, myopia, astigmatism and presbyopia but relatively little is known about their aetiology. In order to explore the potential role of genetic determinants in refractive error the "GEnes in Myopia (GEM) study" was established in 2004. The findings that have resulted from this study have not only provided greater insight into the role of genes and other factors involved in myopia but have also gone some way to uncovering the aetiology of other refractive errors. This review will describe some of the major findings of the GEM study and their relative contribution to the literature, illuminate where the deficiencies are in our understanding of the development of refractive errors and how we will advance this field in the future. Copyright © 2010 Elsevier Ltd. All rights reserved.

  1. Refractive errors among students occupying rooms lighted with incandescent or fluorescent lamps.

    PubMed

    Czepita, Damian; Gosławski, Wojciech; Mojsa, Artur

    2004-01-01

    The purpose of the study was to determine whether the development of refractive errors could be associated with exposure to light emitted by incandescent or fluorescent lamps. 3636 students were examined (1638 boys and 1998 girls, aged 6-18 years, mean age 12.1, SD 3.4). The examination included retinoscopy with cycloplegia. Myopia was defined as refractive error < or = -0.5 D, hyperopia as refractive error > or = +1.5 D, astigmatism as refractive error > 0.5 DC. Anisometropia was diagnosed when the difference in the refraction of both eyes was > 1.0 D. The children and their parents completed a questionnaire on exposure to light at home. Data were analyzed statistically with the chi2 test. P values of less than 0.05 were considered statistically significant. It was found that the use of fluorescent lamps was associated with an increase in the occurrence of hyperopia (P < 0.01). There was no association between sleeping with the light turned on and prevalence of refractive errors.

  2. Method of determining effects of heat-induced irregular refractive index on an optical system.

    PubMed

    Song, Xifa; Li, Lin; Huang, Yifan

    2015-09-01

    The effects of an irregular refractive index on optical performance are examined. A method was developed to express a lens's irregular refractive index distribution. An optical system and its mountings were modeled by a thermomechanical finite element (FE) program in the predicted operating temperature range, -45°C-50°C. FE outputs were elaborated using a MATLAB optimization routine; a nonlinear least squares algorithm was adopted to determine which gradient equation best fit each lens's refractive index distribution. The obtained gradient data were imported into Zemax for sequential ray-tracing analysis. The root mean square spot diameter, modulation transfer function, and diffraction ensquared energy were computed for an optical system under an irregular refractive index and under thermoelastic deformation. These properties are greatly reduced by the irregular refractive index effect, which is one-third to five-sevenths the size of the thermoelastic deformation effect. Thus, thermal analyses of optical systems should consider not only thermoelastic deformation but also refractive index irregularities caused by inhomogeneous temperature.

  3. Age-dependence of the average and equivalent refractive indices of the crystalline lens

    PubMed Central

    Charman, W. Neil; Atchison, David A.

    2013-01-01

    Lens average and equivalent refractive indices are required for purposes such as lens thickness estimation and optical modeling. We modeled the refractive index gradient as a power function of the normalized distance from lens center. Average index along the lens axis was estimated by integration. Equivalent index was estimated by raytracing through a model eye to establish ocular refraction, and then backward raytracing to determine the constant refractive index yielding the same refraction. Assuming center and edge indices remained constant with age, at 1.415 and 1.37 respectively, average axial refractive index increased (1.408 to 1.411) and equivalent index decreased (1.425 to 1.420) with age increase from 20 to 70 years. These values agree well with experimental estimates based on different techniques, although the latter show considerable scatter. The simple model of index gradient gives reasonable estimates of average and equivalent lens indices, although refinements in modeling and measurements are required. PMID:24466474

  4. Decoupling the refractive index from the electrical properties of transparent conducting oxides via periodic superlattices

    PubMed Central

    Caffrey, David; Norton, Emma; Coileáin, Cormac Ó; Smith, Christopher M.; Bulfin, Brendan; Farrell, Leo; Shvets, Igor V.; Fleischer, Karsten

    2016-01-01

    We demonstrate an alternative approach to tuning the refractive index of materials. Current methodologies for tuning the refractive index of a material often result in undesirable changes to the structural or optoelectronic properties. By artificially layering a transparent conducting oxide with a lower refractive index material the overall film retains a desirable conductivity and mobility while acting optically as an effective medium with a modified refractive index. Calculations indicate that, with our refractive index change of 0.2, a significant reduction of reflective losses could be obtained by the utilisation of these structures in optoelectronic devices. Beyond this, periodic superlattice structures present a solution to decouple physical properties where the underlying electronic interaction is governed by different length scales. PMID:27623228

  5. Method of producing optical quality glass having a selected refractive index

    DOEpatents

    Poco, John F.; Hrubesh, Lawrence W.

    2000-01-01

    Optical quality glass having a selected refractive index is produced by a two stage drying process. A gel is produced using sol-gel chemistry techniques and first dried by controlled evaporation until the gel volume reaches a pre-selected value. This pre-selected volume determines the density and refractive index of the finally dried gel. The gel is refilled with solvent in a saturated vapor environment, and then dried again by supercritical extraction of the solvent to form a glass. The glass has a refractive index less than the full density of glass, and the range of achievable refractive indices depends on the composition of the glass. Glasses having different refractive indices chosen from an uninterrupted range of values can be produced from a single precursor solution.

  6. Refractive index variance of cells and tissues measured by quantitative phase imaging.

    PubMed

    Shan, Mingguang; Kandel, Mikhail E; Popescu, Gabriel

    2017-01-23

    The refractive index distribution of cells and tissues governs their interaction with light and can report on morphological modifications associated with disease. Through intensity-based measurements, refractive index information can be extracted only via scattering models that approximate light propagation. As a result, current knowledge of refractive index distributions across various tissues and cell types remains limited. Here we use quantitative phase imaging and the statistical dispersion relation (SDR) to extract information about the refractive index variance in a variety of specimens. Due to the phase-resolved measurement in three-dimensions, our approach yields refractive index results without prior knowledge about the tissue thickness. With the recent progress in quantitative phase imaging systems, we anticipate that using SDR will become routine in assessing tissue optical properties.

  7. 3-dimensional dark traps for low refractive index bio-cells using a single optical fiber Bessel beam.

    PubMed

    Zhang, Yu; Tang, Xiaoyun; Zhang, Yaxun; Su, Wenjie; Liu, Zhihai; Yang, Xinghua; Zhang, Jianzhong; Yang, Jun; Oh, Kyunghwan; Yuan, Libo

    2018-06-15

    We proposed and experimentally demonstrated 3-dimensional dark traps for low refractive index bio-cells using a single optical fiber Bessel beam. The Bessel beam was produced by concatenating single-mode fiber and a step index multimode fiber, which was then focused by a high refractive index glass microsphere integrated on the fiber end facet. The focused Bessel beam provided two dark fields along the axial direction, where stable trapping of low refractive index bio-cells was realized in a high refractive index liquid bath. The all-fiber and seamlessly integrated structure of the proposed scheme can find ample potential as a micro-optical probe in in situ characterization and manipulation of multiple bio-cells with refractive indices lower than that of the liquid bath.

  8. Refractive regression after laser in situ keratomileusis.

    PubMed

    Yan, Mabel K; Chang, John Sm; Chan, Tommy Cy

    2018-04-26

    Uncorrected refractive errors are a leading cause of visual impairment across the world. In today's society, laser in situ keratomileusis (LASIK) has become the most commonly performed surgical procedure to correct refractive errors. However, regression of the initially achieved refractive correction has been a widely observed phenomenon following LASIK since its inception more than two decades ago. Despite technological advances in laser refractive surgery and various proposed management strategies, post-LASIK regression is still frequently observed and has significant implications for the long-term visual performance and quality of life of patients. This review explores the mechanism of refractive regression after both myopic and hyperopic LASIK, predisposing risk factors and its clinical course. In addition, current preventative strategies and therapies are also reviewed. © 2018 Royal Australian and New Zealand College of Ophthalmologists.

  9. [Refractive errors in patients with cerebral palsy].

    PubMed

    Mrugacz, Małgorzata; Bandzul, Krzysztof; Kułak, Wojciech; Poppe, Ewa; Jurowski, Piotr

    2013-04-01

    Ocular changes are common in patients with cerebral palsy (CP) and they exist in about 50% of cases. The most common are refractive errors and strabismus disease. The aim of the paper was to estimate the relativeness between refractive errors and neurological pathologies in patients with selected types of CP. MATERIAL AND METHODS. The subject of the analysis was showing refractive errors in patients within two groups of CP: diplegia spastica and tetraparesis, with nervous system pathologies taken into account. Results. This study was proven some correlations between refractive errors and type of CP and severity of the CP classified in GMFCS scale. Refractive errors were more common in patients with tetraparesis than with diplegia spastica. In the group with diplegia spastica more common were myopia and astigmatism, however in tetraparesis - hyperopia.

  10. Fiber-optic epoxy composite cure sensor. I. Dependence of refractive index of an autocatalytic reaction epoxy system at 850 nm on temperature and extent of cure

    NASA Astrophysics Data System (ADS)

    Lam, Kai-Yuen; Afromowitz, Martin A.

    1995-09-01

    We discuss the behavior of the refractive index of a typical epoxy-aromatic diamine system. Near 850 nm the index of refraction is found to be largely controlled by the density of the epoxy. Models are derived to describe its dependence on temperature and extent of cure. Within the range of temperatures studied, the refractive index decreases linearly with increasing temperature. In addition, as the epoxy is cured, the refractive index increases linearly with conversion to the gel point. >From then on, shrinkage in the volume of the epoxy is restricted by local viscosity. Therefore the linear relationship between the refractive index and the extent of cure does not hold beyond the gel point.

  11. Simultaneous identification of the low-field-induced tiny variation of complex refractive index for anisotropic and opaque magnetic-fluid thin film by a stable heterodyne Mach-Zehnder interferometer.

    PubMed

    Hong, Chin-Yih; Chieh, Jen-Jie; Yang, Shieh-Yueh; Yang, Hong-Chang; Horng, Herng-Er

    2009-10-10

    We use a heterodyne Mach-Zehnder interferometer to simultaneously and simply measure the complex refractive index by only normal incidence on the specimen, instead of using a complicated measurement procedure or instrument that only measures the real or imaginary part of the complex refractive index. To study the tiny variation of the complex refractive index, the small complex refractive-index variation of a rare-concentration magnetic-fluid thin film, due to a weak field of less than 200 Oe, was processed by this interferometer. We also present the wavelength trend of the complex refractive index of magnetic fluids to verify the appearance of the slight change in a small wavelength range.

  12. Image Information Obtained Using a Charge-Coupled Device (CCD) Camera During an Immersion Liquid Evaporation Process for Measuring the Refractive Index of Solid Particles.

    PubMed

    Niskanen, Ilpo; Sutinen, Veijo; Thungström, Göran; Räty, Jukka

    2018-06-01

    The refractive index is a fundamental physical property of a medium, which can be used for the identification and purity issues of all media. Here we describe a refractive index measurement technique to determine simultaneously the refractive index of different solid particles by monitoring the transmittance of light from a suspension using a charge-coupled device (CCD) camera. An important feature of the measurement is the liquid evaporation process for the refractive index matching of the solid particle and the immersion liquid; this was realized by using a pair of volatile and non-volatile immersion liquids. In this study, refractive indices of calcium fluoride (CaF 2 ) and barium fluoride (BaF 2 ) were determined using the proposed method.

  13. Simultaneous measurements of radar reflectivity and refractive index spectra in clear air convection.

    NASA Technical Reports Server (NTRS)

    Konrad, T. G.; Robison, F. L.

    1972-01-01

    Simultaneous measurements of radar reflectivity and radio refractive index at several altitudes in clear air convection have been made. The experimental data were compared with the theoretical relationship which relates the reflectivity to the refractivity spectrum. The agreement between the measurements and the theory is excellent and shows that the radar returns in clear air are the result of, and can be quantitatively described as being from, fine-scale refractivity fluctuations due to turbulent mixing. Further, the data give strong support to the -5/3 spectral decay of the refractivity spectrum in the inertial subrange.

  14. Conical Refraction: new observations and a dual cone model.

    PubMed

    Sokolovskii, G S; Carnegie, D J; Kalkandjiev, T K; Rafailov, E U

    2013-05-06

    We propose a paraxial dual-cone model of conical refraction involving the interference of two cones of light behind the exit face of the crystal. The supporting experiment is based on beam selecting elements breaking down the conically refracted beam into two separate hollow cones which are symmetrical with one another. The shape of these cones of light is a product of a 'competition' between the divergence caused by the conical refraction and the convergence due to the focusing by the lens. The developed mathematical description of the conical refraction demonstrates an excellent agreement with experiment.

  15. Intensification and refraction of acoustical signals in partially choked converging ducts

    NASA Technical Reports Server (NTRS)

    Nayfeh, A. H.

    1980-01-01

    A computer code based on the wave-envelope technique is used to perform detailed numerical calculations for the intensification and refraction of sound in converging hard walled and lined circular ducts carrying high mean Mach number flows. The results show that converging ducts produce substantial refractions toward the duct center for waves propagating against near choked flows. As expected, the magnitude of the refraction decreases as the real part of the admittance increases. The pressure wave pattern is that of interference among the different modes, and hence the variation of the magnitude of pressure refraction with frequency is not monotonic.

  16. Change in refractive index of muscle tissue during laser-induced interstitial thermotherapy.

    PubMed

    Chen, Na; Chen, Meimei; Liu, Shupeng; Guo, Qiang; Chen, Zhenyi; Wang, Tingyun

    2014-01-01

    This paper presents a long-period fiber-grating (LPG) based Michelson interferometric refractometry to monitor the change in refractive index of porcine muscle during laser-induced interstitial thermotherapy (LITT). As the wavelength of RI interferometer alters with the change in refractive index around the probe, the LPG based refractometry is combined with LITT system to measure the change in refractive index of porcine muscle when irradiated by laser. The experimental results show the denaturation of tissue alters the refractive index significantly and the LPG sensor can be applied to monitor the tissue state during the LITT.

  17. Vectorial approach of determining the wave propagation at metasurfaces

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Smith, Daniel, E-mail: D.Smith1966@outlook.com; Campbell, Michael, E-mail: mhl.campbell@gmail.com; Bergmann, Andreas, E-mail: a.bergmann@hotmail.com

    2015-10-15

    Vector approach often benefits optical engineers and physicists, and a vector formulation of the laws of reflection and refraction has been studied (Tkaczyk, 2012). However, the conventional reflection and refraction laws may be violated in the presence of a metasurface, and reflection and refraction at the metasurface obey generalized laws of reflection and refraction (Yu et al., 2011). In this letter, the vectorial laws of reflection and refraction at the metasurface were derived, and the matrix formulation of these vectorial laws are also obtained. These results enable highly efficient and unambiguous computations in ray-tracing problems that involve a metasurface.

  18. Astigmatism

    MedlinePlus

    ... retina, at the back of your eye. A refractive error If either your cornea or lens is egg ... too close to the television or squinting. Other refractive errors Astigmatism may occur in combination with other refractive ...

  19. Fully 3D refraction correction dosimetry system.

    PubMed

    Manjappa, Rakesh; Makki, S Sharath; Kumar, Rajesh; Vasu, Ram Mohan; Kanhirodan, Rajan

    2016-02-21

    The irradiation of selective regions in a polymer gel dosimeter results in an increase in optical density and refractive index (RI) at those regions. An optical tomography-based dosimeter depends on rayline path through the dosimeter to estimate and reconstruct the dose distribution. The refraction of light passing through a dose region results in artefacts in the reconstructed images. These refraction errors are dependant on the scanning geometry and collection optics. We developed a fully 3D image reconstruction algorithm, algebraic reconstruction technique-refraction correction (ART-rc) that corrects for the refractive index mismatches present in a gel dosimeter scanner not only at the boundary, but also for any rayline refraction due to multiple dose regions inside the dosimeter. In this study, simulation and experimental studies have been carried out to reconstruct a 3D dose volume using 2D CCD measurements taken for various views. The study also focuses on the effectiveness of using different refractive-index matching media surrounding the gel dosimeter. Since the optical density is assumed to be low for a dosimeter, the filtered backprojection is routinely used for reconstruction. We carry out the reconstructions using conventional algebraic reconstruction (ART) and refractive index corrected ART (ART-rc) algorithms. The reconstructions based on FDK algorithm for cone-beam tomography has also been carried out for comparison. Line scanners and point detectors, are used to obtain reconstructions plane by plane. The rays passing through dose region with a RI mismatch does not reach the detector in the same plane depending on the angle of incidence and RI. In the fully 3D scanning setup using 2D array detectors, light rays that undergo refraction are still collected and hence can still be accounted for in the reconstruction algorithm. It is found that, for the central region of the dosimeter, the usable radius using ART-rc algorithm with water as RI matched medium is 71.8%, an increase of 6.4% compared to that achieved using conventional ART algorithm. Smaller diameter dosimeters are scanned with dry air scanning by using a wide-angle lens that collects refracted light. The images reconstructed using cone beam geometry is seen to deteriorate in some planes as those regions are not scanned. Refraction correction is important and needs to be taken in to consideration to achieve quantitatively accurate dose reconstructions. Refraction modeling is crucial in array based scanners as it is not possible to identify refracted rays in the sinogram space.

  20. Refractive Errors

    MedlinePlus

    ... and lens of your eye helps you focus. Refractive errors are vision problems that happen when the shape ... cornea, or aging of the lens. Four common refractive errors are Myopia, or nearsightedness - clear vision close up ...

  1. Refraction test

    MedlinePlus

    ... purpose is to determine whether you have a refractive error (a need for glasses or contact lenses). For ... glasses or contact lenses) is normal, then the refractive error is zero (plano) and your vision should be ...

  2. Stochastic digital holography for visualizing inside strongly refracting transparent objects.

    PubMed

    Desse, Jean-Michel; Picart, Pascal

    2015-01-01

    This paper presents a digital holographic method to visualize and measure refractive index variations, convection currents, or thermal gradients, occurring inside a transparent and refracting object. The proof of principle is provided through the visualization of refractive index variation inside a lighting bulb. Comparison with transmission and reflection holography is also provided. A very good agreement is obtained, thus validating the proposed approach.

  3. Influence of the apex angle of a hollow prism made from an ordinary commercial glass plate as a simple refractometer to the accuracy of the refractive index measurement of the edible oil

    NASA Astrophysics Data System (ADS)

    Idris, N.; Maswati; Yusibani, E.

    2018-05-01

    The influence of the apex angle of a hollow prism used as a simple refractometer to the accuracy of a refractive index measurement of the edible oil samples was studied. The hollow prism was made from an ordinary commercial glass plate with a thickness of 2 mm. The apex angle of the constructed hollow prism was varied. The edible oil sample used in this study was palm oil, namely the packaged, branded oil sample and the bulk oil sample. For measuring the refractive index, the oil sample was filled in the constructed hollow prism, and then a helium-neon laser beam was passed through the oil sample at a certain angle of incidence. The angle of minimum deviation of the transmitted laser He-Ne beam was measured and then was used for calculating the refractive index of the oil sample. The refractive index measurement was made using the hollow prism with different apex angles, ranging from 300 to 600. The measurement accuracy was estimated by comparing the refractive index measured using the hollow prisms to that of obtained using a standard Abbe refractometer. It was found that the refractive index of the edible oil can be measured accurately by using the hollow prism. It was also found that the accuracy of the refractive index measurement significantly changes with the apex angle of the hollow prism. The refractive index values measured using this simple refractometer deviate up to 3,49% from the refractive index value measured using the standard Abbe refractometer, especially when the apex angle of the prism is 30°. The measurement results with high accuracies obtained when using the hollow prisms with apex angles of 450 and 600. The optimum apex angle for the present constructed hollow prism is 450. The refractive index obtained using the hollow prism with the apex angle of 450 is 1,4623 and 1,4438 for the bulk oil and the packed, branded oil samples, respectively. This result suggests that the apex angle of the prism used affects largely the accuracy of the refractive index measurement.

  4. Evaluation of visual acuity measurements after autorefraction vs manual refraction in eyes with and without diabetic macular edema.

    PubMed

    Sun, Jennifer K; Qin, Haijing; Aiello, Lloyd Paul; Melia, Michele; Beck, Roy W; Andreoli, Christopher M; Edwards, Paul A; Glassman, Adam R; Pavlica, Michael R

    2012-04-01

    To compare visual acuity (VA) scores after autorefraction vs manual refraction in eyes of patients with diabetes mellitus and a wide range of VAs. The letter score from the Electronic Visual Acuity (EVA) test from the electronic Early Treatment Diabetic Retinopathy Study was measured after autorefraction (AR-EVA score) and after manual refraction (MR-EVA score), which is the research protocol of the Diabetic Retinopathy Clinical Research Network. Testing order was randomized, study participants and VA examiners were masked to refraction source, and a second EVA test using an identical supplemental manual refraction (MR-EVAsuppl score) was performed to determine test-retest variability. In 878 eyes of 456 study participants, the median MR-EVA score was 74 (Snellen equivalent, approximately 20/32). The spherical equivalent was often similar for manual refraction and autorefraction (median difference, 0.00; 5th-95th percentile range, -1.75 to 1.13 diopters). However, on average, the MR-EVA scores were slightly better than the AR-EVA scores, across the entire VA range. Furthermore, the variability between the AR-EVA scores and the MR-EVA scores was substantially greater than the test-retest variability of the MR-EVA scores (P < .001). The variability of differences was highly dependent on the autorefractor model. Across a wide range of VAs at multiple sites using a variety of autorefractors, VA measurements tend to be worse with autorefraction than manual refraction. Differences between individual autorefractor models were identified. However, even among autorefractor models that compare most favorably with manual refraction, VA variability between autorefraction and manual refraction is higher than the test-retest variability of manual refraction. The results suggest that, with current instruments, autorefraction is not an acceptable substitute for manual refraction for most clinical trials with primary outcomes dependent on best-corrected VA.

  5. Cycloplegic autorefraction versus subjective refraction: the Tehran Eye Study.

    PubMed

    Hashemi, Hassan; Khabazkhoob, Mehdi; Asharlous, Amir; Soroush, Sara; Yekta, AbbasAli; Dadbin, Nooshin; Fotouhi, Akbar

    2016-08-01

    To compare cycloplegic autorefraction with non-cycloplegic subjective refraction across all age and refractive error groups. In a cross-sectional study with random stratified cluster sampling, 160 clusters were chosen from various districts proportionate to the population of each district in Tehran. Following retinoscopy and autorefraction with the 0.25 D bracketing (Topcon KR-8000, Topcon, Tokyo, Japan), all participants had a subjective refraction. Then all participants underwent cycloplegic autorefraction. The final analysis was performed on 3482 participants with a mean age of 31.7 years (range 5-92 years). Based on cycloplegic and subjective refraction, mean spherical equivalent (SE) was +0.31±1.80 and -0.32±1.61 D, respectively (p<0.001). The 95% limits of agreement (LoA) between these two types of refraction were from -0.40 to 1.70 D. The largest difference between these two types of refraction was seen in the age group of 5-10 years (1.11±0.60 D), and the smallest difference was in the age group of >70 years (0.34±0.45 D). The 95% LoA was -0.52 to 0.89 D in patients with myopia and -0.12 to 2.04 D in patients with hyperopia. We found that female gender (coefficients=0.048), older age (coefficients=-0.247), higher education (coefficients=-0.043) and cycloplegic SE (coefficients=-0.472) significantly correlated with lower intermethod differences. The cycloplegic refraction is more sensitive than the subjective one to measure refractive error at all age groups especially in children and young adults. The cyclorefraction technique is highly recommended to exactly measure the refractive error in momentous conditions such as refractive surgery, epidemiological researches and amblyopia therapy, especially in hypermetropic eyes and paediatric cases. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  6. Prevalence and pattern of refractive errors among primary school children in Al Hassa , Saudi Arabia.

    PubMed

    Al Wadaani, Fahd Abdullah; Amin, Tarek Tawfik; Ali, Ayub; Khan, Atuar Rahman

    2012-11-11

    Some 12.8 million in the age group 5-15 years are visually impaired from uncorrected or inadequately corrected refractive errors. In Saudi Arabia, the size of this public health problem is not well defined especially among primary schoolchildren. The purpose of this cross-sectional study was to assess the prevalence and pattern of refractive errors among primary school children in Al Hassa, Saudi Arabia.  A total of 2246 Saudi primary school children aged 6 to 14 years of both genders were selected using multistage sampling method form 30 primary schools located in the three different areas of Al Hassa. School children were interviewed to collect demographics and vision data using a special data collection form followed by screening for refractive errors by trained optometrists within the school premises using a standardized protocol. Assessment of visual acuity and ocular motility evaluation were carried out and cover-uncover test was performed. Children detected with defective vision were referred for further examination employing subjective refraction with auto refractometer and objective refraction using streak retinoscopy after 1% cyclopentolate. Of the screened school children (N=2002), the overall prevalence of refractive errors was 13.7% (n=274), higher among females (Odds ratio, OR=1.39, P=0.012) and significantly more among students of rural residence (OR=2.40, P=0.001). The prevalence of refractive errors was disproportionately more among those aged 12-14 years (OR=9.02, P=0.001). Only 9.4% of students with poor vision were wore spectacles for correction. Myopia was the most commonly encountered refractive error among both genders (65.7% of the total errors encountered). Uncorrected refractive errors affected a sizable portion of primary school children in Al Hassa, Saudi Arabia. Primary schoolchildren especially females, rural and older children represents high risk group for refractive errors for which the included children were unaware.

  7. Prevalence and Pattern of Refractive Errors among Primary School Children in Al Hassa, Saudi Arabia

    PubMed Central

    Wadaani, Fahd Abdullah Al; Amin, Tarek Tawfik; Ali, Ayub; Khan, Ataur Rahman

    2013-01-01

    Some 12.8 million in the age group 5–15 years are visually impaired from uncorrected or inadequately corrected refractive errors. In Saudi Arabia, the size of this public health problem is not well defined especially among primary schoolchildren. The purpose of this cross-sectional study was to assess the prevalence and pattern of refractive errors among primary school children in Al Hassa, Saudi Arabia. A total of 2246 Saudi primary school children aged 6 to 14 years of both genders were selected using multistage sampling method form 30 primary schools located in the three different areas of Al Hassa. School children were interviewed to collect demographics and vision data using a special data collection form followed by screening for refractive errors by trained optometrists within the school premises using a standardized protocol. Assessment of visual acuity and ocular motility evaluation were carried out and cover-uncover test was performed. Children detected with defective vision were referred for further examination employing subjective refraction with auto refractometer and objective refraction using streak retinoscopy after 1% cyclopentolate. Of the screened school children (N=2002), the overall prevalence of refractive errors was 13.7% (n=274), higher among females (Odds ratio, OR=1.39, P=0.012) and significantly more among students of rural residence (OR=2.40, P=0.001). The prevalence of refractive errors was disproportionately more among those aged 12-14 years (OR=9.02, P=0.001). Only 9.4% of students with poor vision were wore spectacles for correction. Myopia was the most commonly encountered refractive error among both genders (65.7% of the total errors encountered). Uncorrected refractive errors affected a sizable portion of primary school children in Al Hassa, Saudi Arabia. Primary schoolchildren especially females, rural and older children represents high risk group for refractive errors for which the included children were unaware. PMID:23283044

  8. Refractive error and presbyopia among adults in Fiji.

    PubMed

    Brian, Garry; Pearce, Matthew G; Ramke, Jacqueline

    2011-04-01

    To characterize refractive error, presbyopia and their correction among adults aged ≥ 40 years in Fiji, and contribute to a regional overview of these conditions. A population-based cross-sectional survey using multistage cluster random sampling. Presenting distance and near vision were measured and dilated slitlamp examination performed. The survey achieved 73.0% participation (n=1381). Presenting binocular distance vision ≥ 6/18 was achieved by 1223 participants. Another 79 had vision impaired by refractive error. Three of these were blind. At threshold 6/18, 204 participants had refractive error. Among these, 125 had spectacle-corrected presenting vision ≥ 6/18 ("met refractive error need"); 79 presented wearing no (n=74) or under-correcting (n=5) distance spectacles ("unmet refractive error need"). Presenting binocular near vision ≥ N8 was achieved by 833 participants. At threshold N8, 811 participants had presbyopia. Among these, 336 attained N8 with presenting near spectacles ("met presbyopia need"); 475 presented with no (n=402) or under-correcting (n=73) near spectacles ("unmet presbyopia need"). Rural residence was predictive of unmet refractive error (p=0.040) and presbyopia (p=0.016) need. Gender and household income source were not. Ethnicity-gender-age-domicile-adjusted to the Fiji population aged ≥ 40 years, "met refractive error need" was 10.3% (95% confidence interval [CI] 8.7-11.9%), "unmet refractive error need" was 4.8% (95%CI 3.6-5.9%), "refractive error correction coverage" was 68.3% (95%CI 54.4-82.2%),"met presbyopia need" was 24.6% (95%CI 22.4-26.9%), "unmet presbyopia need" was 33.8% (95%CI 31.3-36.3%), and "presbyopia correction coverage" was 42.2% (95%CI 37.6-46.8%). Fiji refraction and dispensing services should encourage uptake by rural dwellers and promote presbyopia correction. Lack of comparable data from neighbouring countries prevents a regional overview.

  9. Patient-reported Outcomes for Assessment of Quality of Life in Refractive Error: A Systematic Review.

    PubMed

    Kandel, Himal; Khadka, Jyoti; Goggin, Michael; Pesudovs, Konrad

    2017-12-01

    This review has identified the best existing patient-reported outcome (PRO) instruments in refractive error. The article highlights the limitations of the existing instruments and discusses the way forward. A systematic review was conducted to identify the types of PROs used in refractive error, to determine the quality of the existing PRO instruments in terms of their psychometric properties, and to determine the limitations in the content of the existing PRO instruments. Articles describing a PRO instrument measuring 1 or more domains of quality of life in people with refractive error were identified by electronic searches on the MEDLINE, PubMed, Scopus, Web of Science, and Cochrane databases. The information on content development, psychometric properties, validity, reliability, and responsiveness of those PRO instruments was extracted from the selected articles. The analysis was done based on a comprehensive set of assessment criteria. One hundred forty-eight articles describing 47 PRO instruments in refractive error were included in the review. Most of the articles (99 [66.9%]) used refractive error-specific PRO instruments. The PRO instruments comprised 19 refractive, 12 vision but nonrefractive, and 16 generic PRO instruments. Only 17 PRO instruments were validated in refractive error populations; six of them were developed using Rasch analysis. None of the PRO instruments has items across all domains of quality of life. The Quality of Life Impact of Refractive Correction, the Quality of Vision, and the Contact Lens Impact on Quality of Life have comparatively better quality with some limitations, compared with the other PRO instruments. This review describes the PRO instruments and informs the choice of an appropriate measure in refractive error. We identified need of a comprehensive and scientifically robust refractive error-specific PRO instrument. Item banking and computer-adaptive testing system can be the way to provide such an instrument.

  10. A modified artificial neural network based prediction technique for tropospheric radio refractivity

    PubMed Central

    Javeed, Shumaila; Javed, Wajahat; Atif, M.; Uddin, Mueen

    2018-01-01

    Radio refractivity plays a significant role in the development and design of radio systems for attaining the best level of performance. Refractivity in the troposphere is one of the features affecting electromagnetic waves, and hence the communication system interrupts. In this work, a modified artificial neural network (ANN) based model is applied to predict the refractivity. The suggested ANN model comprises three modules: the data preparation module, the feature selection module, and the forecast module. The first module applies pre-processing to make the data compatible for the feature selection module. The second module discards irrelevant and redundant data from the input set. The third module uses ANN for prediction. The ANN model applies a sigmoid activation function and a multi-variate auto regressive model to update the weights during the training process. In this work, the refractivity is predicted and estimated based on ten years (2002–2011) of meteorological data, such as the temperature, pressure, and humidity, obtained from the Pakistan Meteorological Department (PMD), Islamabad. The refractivity is estimated using the method suggested by the International Telecommunication Union (ITU). The refractivity is predicted for the year 2012 using the database of the previous ten years, with the help of ANN. The ANN model is implemented in MATLAB. Next, the estimated and predicted refractivity levels are validated against each other. The predicted and actual values (PMD data) of the atmospheric parameters agree with each other well, and demonstrate the accuracy of the proposed ANN method. It was further found that all parameters have a strong relationship with refractivity, in particular the temperature and humidity. The refractivity values are higher during the rainy season owing to a strong association with the relative humidity. Therefore, it is important to properly cater the signal communication system during hot and humid weather. Based on the results, the proposed ANN method can be used to develop a refractivity database, which is highly important in a radio communication system. PMID:29494609

  11. Refractive Lenticule Transplantation for Correction of Iatrogenic Hyperopia and High Astigmatism After LASIK.

    PubMed

    Lazaridis, Apostolos; Reinstein, Dan Z; Archer, Timothy J; Schulze, Stephan; Sekundo, Walter

    2016-11-01

    To design a technique for intrastromal transplantation of stromal lenticules with specific refractive power for correction of post-LASIK induced hyperopia and astigmatism. A 28-year-old patient was referred for consultation after complicated LASIK for moderate myopia and astigmatism. The refractive error of the right eye was severely overcorrected due to data entry error. Post-LASIK refraction showed high astigmatism (right eye: +6.50 -9.00 @ 84°) and corrected distance visual acuity (CDVA) of 20/32. The corneal thickness was 282 µm. A refractive lenticule transplantation was performed due to contact lens intolerance, poor visual acuity, and severe anisometropia. A toric and myopic lenticule, obtained from a donor using the femtosecond lenticule extraction technique, was implanted under the flap to reduce the refractive error, bring the refraction of the eye to the level correctable by phakic intraocular lens, and restore corneal volume. Six weeks postoperatively, the donor lenticule was spread smoothly in the interface with a minor temporal decentration in relation to pupil center. The refraction showed a reduction of astigmatism but a stronger myopization compared to preoperative calculations (right eye: -6.50 -4.00 @ 70°). At 3 months, the CDVA returned to the preoperative value of 20/32. One year postoperatively, corneal tomography showed no signs of ectasia and biomicroscopy revealed no signs of rejection. After implanting a toric myopic implantable collamer lens, the patient regained uncorrected distance visual acuity of 20/40 and full stereopsis. The refractive lenticule transplantation technique offers a solution for rare cases of post-LASIK hyperopia and high astigmatism while restoring the volume of thin corneas. Moreover, it is a reversible procedure with low probability of rejection. [J Refract Surg. 2016;32(11):780-786.]. Copyright 2016, SLACK Incorporated.

  12. Mixed effects modelling for glass category estimation from glass refractive indices.

    PubMed

    Lucy, David; Zadora, Grzegorz

    2011-10-10

    520 Glass fragments were taken from 105 glass items. Each item was either a container, a window, or glass from an automobile. Each of these three classes of use are defined as glass categories. Refractive indexes were measured both before, and after a programme of re-annealing. Because the refractive index of each fragment could not in itself be observed before and after re-annealing, a model based approach was used to estimate the change in refractive index for each glass category. It was found that less complex estimation methods would be equivalent to the full model, and were subsequently used. The change in refractive index was then used to calculate a measure of the evidential value for each item belonging to each glass category. The distributions of refractive index change were considered for each glass category, and it was found that, possibly due to small samples, members of the normal family would not adequately model the refractive index changes within two of the use types considered here. Two alternative approaches to modelling the change in refractive index were used, one employed more established kernel density estimates, the other a newer approach called log-concave estimation. Either method when applied to the change in refractive index was found to give good estimates of glass category, however, on all performance metrics kernel density estimates were found to be slightly better than log-concave estimates, although the estimates from log-concave estimation prossessed properties which had some qualitative appeal not encapsulated in the selected measures of performance. These results and implications of these two methods of estimating probability densities for glass refractive indexes are discussed. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  13. Automated refraction is stable 1 week after uncomplicated cataract surgery.

    PubMed

    Ostri, Christoffer; Holfort, Stig K; Fich, Marianne S; Riise, Per

    2018-03-01

    To compare automated refraction 1 week and 1 month after uncomplicated cataract surgery. In this prospective cohort study, we recruited patients in a 2-month period and included consecutive patients scheduled for bilateral small-incision phacoemulsification cataract surgery. The exclusion criteria were (i) corneal and/or retinal pathology that could lead to automated refraction miscalculation and (ii) surgery complications. Automated refraction was measured 1 week and 1 month after surgery. Ninety-five patients met the in- and exclusion criteria and completed follow-up. The mean refractive shift in spherical equivalent was -0.02 dioptre (D) between 1 week and 1 month after surgery and not statistical significant (p = 0.78, paired t-test). The magnitude of refractive shift in either myopic or hyperopic direction was neither correlated to age, preoperative corneal astigmatism, axial length nor phacoemulsification energy used during surgery (p > 0.05 for all variables, regression analysis). The refractive target was missed with 1.0 D or more in 11 (12%) patients. In this subgroup, the mean refractive shift in spherical equivalent was 0.49 D between 1 week and 1 month after surgery with a trend towards statistical significance (p = 0.07, paired t-test). There was no difference in age, preoperative corneal astigmatism, axial length or phacoemulsification energy used during surgery compared to the remainder of the patients (p > 0.05 for all variables, unpaired t-test). Automated refraction is stabile 1 week after uncomplicated cataract surgery, but there is a trend towards instability, if the refractive target is missed with 1.0 D or more. © 2017 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  14. Evaluation of Visual Acuity Measurements after Autorefraction versus Manual Refraction in Eyes with and without Diabetic Macular Edema

    PubMed Central

    Sun, Jennifer K.; Qin, Haijing; Aiello, Lloyd Paul; Melia, Michele; Beck, Roy W.; Andreoli, Christopher M.; Edwards, Paul A.; Glassman, Adam R.; Pavlica, Michael R.

    2012-01-01

    Objective To compare visual acuity (VA) scores after autorefraction versus research protocol manual refraction in eyes of patients with diabetes and a wide range of VA. Methods Electronic Early Treatment Diabetic Retinopathy Study (E-ETDRS) VA Test© letter score (EVA) was measured after autorefraction (AR-EVA) and after Diabetic Retinopathy Clinical Research Network (DRCR.net) protocol manual refraction (MR-EVA). Testing order was randomized, study participants and VA examiners were masked to refraction source, and a second EVA utilizing an identical manual refraction (MR-EVAsupl) was performed to determine test-retest variability. Results In 878 eyes of 456 study participants, median MR-EVA was 74 (Snellen equivalent approximately 20/32). Spherical equivalent was often similar for manual and autorefraction (median difference: 0.00, 5th and 95th percentiles −1.75 to +1.13 Diopters). However, on average, MR-EVA results were slightly better than AR-EVA results across the entire VA range. Furthermore, variability between AR-EVA and MR-EVA was substantially greater than the test-retest variability of MR-EVA (P<0.001). Variability of differences was highly dependent on autorefractor model. Conclusions Across a wide range of VA at multiple sites using a variety of autorefractors, VA measurements tend to be worse with autorefraction than manual refraction. Differences between individual autorefractor models were identified. However, even among autorefractor models comparing most favorably to manual refraction, VA variability between autorefraction and manual refraction is higher than the test-retest variability of manual refraction. The results suggest that with current instruments, autorefraction is not an acceptable substitute for manual refraction for most clinical trials with primary outcomes dependent on best-corrected VA. PMID:22159173

  15. Comparison of Methods for Predicting the Compositional Dependence of the Density and Refractive Index of Organic-Aqueous Aerosols.

    PubMed

    Cai, Chen; Miles, Rachael E H; Cotterell, Michael I; Marsh, Aleksandra; Rovelli, Grazia; Rickards, Andrew M J; Zhang, Yun-Hong; Reid, Jonathan P

    2016-08-25

    Representing the physicochemical properties of aerosol particles of complex composition is of crucial importance for understanding and predicting aerosol thermodynamic, kinetic, and optical properties and processes and for interpreting and comparing analysis methods. Here, we consider the representations of the density and refractive index of aqueous-organic aerosol with a particular focus on the dependence of these properties on relative humidity and water content, including an examination of the properties of solution aerosol droplets existing at supersaturated solute concentrations. Using bulk phase measurements of density and refractive index for typical organic aerosol components, we provide robust approaches for the estimation of these properties for aerosol at any intermediate composition between pure water and pure solute. Approximately 70 compounds are considered, including mono-, di- and tricarboxylic acids, alcohols, diols, nitriles, sulfoxides, amides, ethers, sugars, amino acids, aminium sulfates, and polyols. We conclude that the molar refraction mixing rule should be used to predict the refractive index of the solution using a density treatment that assumes ideal mixing or, preferably, a polynomial dependence on the square root of the mass fraction of solute, depending on the solubility limit of the organic component. Although the uncertainties in the density and refractive index predictions depend on the range of subsaturated compositional data available for each compound, typical errors for estimating the solution density and refractive index are less than ±0.1% and ±0.05%, respectively. Owing to the direct connection between molar refraction and the molecular polarizability, along with the availability of group contribution models for predicting molecular polarizability for organic species, our rigorous testing of the molar refraction mixing rule provides a route to predicting refractive indices for aqueous solutions containing organic molecules of arbitrary structure.

  16. Eye laterality: a comprehensive analysis in refractive surgery candidates.

    PubMed

    Linke, Stephan J; Druchkiv, Vasyl; Steinberg, Johannes; Richard, Gisbert; Katz, Toam

    2013-08-01

    To explore eye laterality (higher refractive error in one eye) and its association with refractive state, spherical/astigmatic anisometropia, age and sex in refractive surgery candidates. Medical records of 12 493 consecutive refractive surgery candidates were filtered. Refractive error (subjective and cycloplegic) was measured in each subject and correlated with eye laterality. Only subjects with corrected distance visual acuity (CDVA) of >20/22 in each eye were enrolled to exclude amblyopia. Associations between eye laterality and refractive state were analysed by means of t-test, chi-squared test, Spearman's correlation and multivariate logistic regression analysis, respectively. There was no statistically significant difference in spherical equivalent between right (-3.47 ± 2.76 D) and left eyes (-3.47 ± 2.76 D, p = 0.510; Pearson's r = 0.948, p < 0.001). Subgroup analysis revealed (I) right eye laterality for anisometropia >2.5 D in myopic (-5.64 ± 2.5 D versus -4.92 ± 2.6 D; p = 0.001) and in hyperopic (4.44 ± 1.69 D versus 3.04 ± 1.79 D; p = 0.025) subjects, (II) a tendency for left eye cylindrical laterality in myopic subjects, and (III) myopic male subjects had a higher prevalence of left eye laterality. (IV) Age did not show any significant impact on laterality. Over the full refractive spectrum, this study confirmed previously described strong interocular refractive correlation but revealed a statistically significant higher rate of right eye laterality for anisometropia >2.5 D. In general, our results support the use of data from one eye only in studies of ocular refraction. © 2013 The Authors. Acta Ophthalmologica © 2013 Acta Ophthalmologica Scandinavica Foundation.

  17. Peripheral defocus does not necessarily affect central refractive development.

    PubMed

    Schippert, Ruth; Schaeffel, Frank

    2006-10-01

    Recent experiments in monkeys suggest that deprivation, imposed only in the periphery of the visual field, can induce foveal myopia. This raises the hypothesis that peripheral refractive errors imposed by the spectacle lens correction could influence foveal refractive development also in humans. We have tested this hypothesis in chicks. Chicks wore either full field spectacle lenses (+6.9 D/-7 D), or lenses with central holes of 4, 6, or 8mm diameter, for 4 days (n=6 for each group). Refractions were measured in the central visual field, and at -45 degrees (temporal) and +45 degrees (nasal), and axial lengths were measured by A-scan ultrasonography. As previously described, full field lenses were largely compensated within 4 days (refraction changes with positive lenses: +4.69+/-1.73 D, negative lenses: -5.98+/-1.78 D, both p<0.001, Dunnett's test, to untreated controls). With holes in the center of the lenses, the central refraction remained emmetropic and there was not even a trend of a shift in refraction (all groups: p>0.5, Dunnetts test). At +/-45 degrees , the lenses were partially compensated despite the 4/6/8mm central holes; positive lenses: +2.63 / +1.44 / +0.43 D, negative lenses: -2.57 / -1.06 / +0.06 D. There is extensive local compensation of imposed refractive errors in chickens. For the tested hole sizes, peripherally imposed defocus did not influence central refractive development. To alter central refractive development, the unobstructed part in the central visual field may have to be quite small (hole sizes smaller than 4mm, with the lenses at a vertex distance of 2-3mm).

  18. Five-Year Progression of Refractive Errors and Incidence of Myopia in School-Aged Children in Western China

    PubMed Central

    Zhou, Wen-Jun; Zhang, Yong-Ye; Li, Hua; Wu, Yu-Fei; Xu, Ji; Lv, Sha; Li, Ge; Liu, Shi-Chun; Song, Sheng-Fang

    2016-01-01

    Background To determine the change in refractive error and the incidence of myopia among school-aged children in the Yongchuan District of Chongqing City, Western China. Methods A population-based cross-sectional survey was initially conducted in 2006 among 3070 children aged 6 to 15 years. A longitudinal follow-up study was then conducted 5 years later between November 2011 and March 2012. Refractive error was measured under cycloplegia with autorefraction. Age, sex, and baseline refractive error were evaluated as risk factors for progression of refractive error and incidence of myopia. Results Longitudinal data were available for 1858 children (60.5%). The cumulative mean change in refractive error was −2.21 (standard deviation [SD], 1.87) diopters (D) for the entire study population, with an annual progression of refraction in a myopic direction of −0.43 D. Myopic progression of refractive error was associated with younger age, female sex, and higher myopic or hyperopic refractive error at baseline. The cumulative incidence of myopia, defined as a spherical equivalent refractive error of −0.50 D or more, among initial emmetropes and hyperopes was 54.9% (95% confidence interval [CI], 45.2%–63.5%), with an annual incidence of 10.6% (95% CI, 8.7%–13.1%). Myopia was found more likely to happen in female and older children. Conclusions In Western China, both myopic progression and incidence of myopia were higher than those of children from most other locations in China and from the European Caucasian population. Compared with a previous study in China, there was a relative increase in annual myopia progression and annual myopia incidence, a finding which is consistent with the increasing trend on prevalence of myopia in China. PMID:26875599

  19. Relative Proportion Of Different Types Of Refractive Errors In Subjects Seeking Laser Vision Correction

    PubMed Central

    Althomali, Talal A.

    2018-01-01

    Background: Refractive errors are a form of optical defect affecting more than 2.3 billion people worldwide. As refractive errors are a major contributor of mild to moderate vision impairment, assessment of their relative proportion would be helpful in the strategic planning of health programs. Purpose: To determine the pattern of the relative proportion of types of refractive errors among the adult candidates seeking laser assisted refractive correction in a private clinic setting in Saudi Arabia. Methods: The clinical charts of 687 patients (1374 eyes) with mean age 27.6 ± 7.5 years who desired laser vision correction and underwent a pre-LASIK work-up were reviewed retrospectively. Refractive errors were classified as myopia, hyperopia and astigmatism. Manifest refraction spherical equivalent (MRSE) was applied to define refractive errors. Outcome Measures: Distribution percentage of different types of refractive errors; myopia, hyperopia and astigmatism. Results: The mean spherical equivalent for 1374 eyes was -3.11 ± 2.88 D. Of the total 1374 eyes, 91.8% (n = 1262) eyes had myopia, 4.7% (n = 65) eyes had hyperopia and 3.4% (n = 47) had emmetropia with astigmatism. Distribution percentage of astigmatism (cylinder error of ≥ 0.50 D) was 78.5% (1078/1374 eyes); of which % 69.1% (994/1374) had low to moderate astigmatism and 9.4% (129/1374) had high astigmatism. Conclusion and Relevance: Of the adult candidates seeking laser refractive correction in a private setting in Saudi Arabia, myopia represented greatest burden with more than 90% myopic eyes, compared to hyperopia in nearly 5% eyes. Astigmatism was present in more than 78% eyes. PMID:29872484

  20. Refractive errors in 3-6 year-old Chinese children: a very low prevalence of myopia?

    PubMed

    Lan, Weizhong; Zhao, Feng; Lin, Lixia; Li, Zhen; Zeng, Junwen; Yang, Zhikuan; Morgan, Ian G

    2013-01-01

    To examine the prevalence of refractive errors in children aged 3-6 years in China. Children were recruited for a trial of a home-based amblyopia screening kit in Guangzhou preschools, during which cycloplegic refractions were measured in both eyes of 2480 children. Cycloplegic refraction (from 3 to 4 drops of 1% cyclopentolate to ensure abolition of the light reflex) was measured by both autorefraction and retinoscopy. Refractive errors were defined as followed: myopia (at least -0.50 D in the worse eye), hyperopia (at least +2.00 D in the worse eye) and astigmatism (at least 1.50 D in the worse eye). Different definitions, as specified in the text, were also used to facilitate comparison with other studies. The mean spherical equivalent refractive error was at least +1.22 D for all ages and both genders. The prevalence of myopia for any definition at any age was at most 2.5%, and lower in most cases. In contrast, the prevalence of hyperopia was generally over 20%, and declined slightly with age. The prevalence of astigmatism was between 6% and 11%. There was very little change in refractive error with age over this age range. Previous reports of less hyperopic mean spherical equivalent refractive error, and more myopia and less hyperopia in children of this age may be due to problems with achieving adequate cycloplegia in children with dark irises. Using up to 4 drops of 1% cyclopentolate may be necessary to accurately measure refractive error in paediatric studies of such children. Our results suggest that children from all ethnic groups may follow a similar pattern of early refractive development, with little myopia and a hyperopic mean spherical equivalent over +1.00 D up to the age of 5-6 years in most conditions.

  1. Five-Year Progression of Refractive Errors and Incidence of Myopia in School-Aged Children in Western China.

    PubMed

    Zhou, Wen-Jun; Zhang, Yong-Ye; Li, Hua; Wu, Yu-Fei; Xu, Ji; Lv, Sha; Li, Ge; Liu, Shi-Chun; Song, Sheng-Fang

    2016-07-05

    To determine the change in refractive error and the incidence of myopia among school-aged children in the Yongchuan District of Chongqing City, Western China. A population-based cross-sectional survey was initially conducted in 2006 among 3070 children aged 6 to 15 years. A longitudinal follow-up study was then conducted 5 years later between November 2011 and March 2012. Refractive error was measured under cycloplegia with autorefraction. Age, sex, and baseline refractive error were evaluated as risk factors for progression of refractive error and incidence of myopia. Longitudinal data were available for 1858 children (60.5%). The cumulative mean change in refractive error was -2.21 (standard deviation [SD], 1.87) diopters (D) for the entire study population, with an annual progression of refraction in a myopic direction of -0.43 D. Myopic progression of refractive error was associated with younger age, female sex, and higher myopic or hyperopic refractive error at baseline. The cumulative incidence of myopia, defined as a spherical equivalent refractive error of -0.50 D or more, among initial emmetropes and hyperopes was 54.9% (95% confidence interval [CI], 45.2%-63.5%), with an annual incidence of 10.6% (95% CI, 8.7%-13.1%). Myopia was found more likely to happen in female and older children. In Western China, both myopic progression and incidence of myopia were higher than those of children from most other locations in China and from the European Caucasian population. Compared with a previous study in China, there was a relative increase in annual myopia progression and annual myopia incidence, a finding which is consistent with the increasing trend on prevalence of myopia in China.

  2. Refractive errors in patients with newly diagnosed diabetes mellitus.

    PubMed

    Yarbağ, Abdülhekim; Yazar, Hayrullah; Akdoğan, Mehmet; Pekgör, Ahmet; Kaleli, Suleyman

    2015-01-01

    Diabetes mellitus is a complex metabolic disorder that involves the small blood vessels, often causing widespread damage to tissues, including the eyes' optic refractive error. In patients with newly diagnosed diabetes mellitus who have unstable blood glucose levels, refraction may be incorrect. We aimed to investigate refraction in patients who were recently diagnosed with diabetes and treated at our centre. This prospective study was performed from February 2013 to January 2014. Patients were diagnosed with diabetes mellitus using laboratory biochemical tests and clinical examination. Venous fasting plasma glucose (fpg) levels were measured along with refractive errors. Two measurements were taken: initially and after four weeks. The last difference between the initial and end refractive measurements were evaluated. Our patients were 100 males and 30 females who had been newly diagnosed with type II DM. The refractive and fpg levels were measured twice in all patients. The average values of the initial measurements were as follows: fpg level, 415 mg/dl; average refractive value, +2.5 D (Dioptres). The average end of period measurements were fpg, 203 mg/dl; average refractive value, +0.75 D. There is a statistically significant difference between after four weeks measurements with initially measurements of fasting plasma glucose (fpg) levels (p<0.05) and there is a statistically significant relationship between changes in fpg changes with glasses ID (p<0.05) and the disappearance of blurred vision (to be greater than 50% success rate) were statistically significant (p<0.05). Also, were detected upon all these results the absence of any age and sex effects (p>0.05). Refractive error is affected in patients with newly diagnosed diabetes mellitus; therefore, plasma glucose levels should be considered in the selection of glasses.

  3. Population-based survey of refractive error among school-aged children in rural northern China: the Heilongjiang eye study.

    PubMed

    Li, Zhijian; Xu, Keke; Wu, Shubin; Lv, Jia; Jin, Di; Song, Zhen; Wang, Zhongliang; Liu, Ping

    2014-01-01

    The prevalence of refractive error in the north of China is unknown. The study aimed to estimate the prevalence and associated factors of refractive error in school-aged children in a rural area of northern China. Cross-sectional study. The cluster random sampling method was used to select the sample. A total of 1700 subjects of 5 to 18 years of age were examined. All participants underwent ophthalmic evaluation. Refraction was performed under cycloplegia. Association of refractive errors with age, sex, and education was analysed. The main outcome measure was prevalence rates of refractive error among school-aged children. Of the 1700 responders, 1675 were eligible. The prevalence of uncorrected, presenting, and best-corrected visual acuity of 20/40 or worse in the better eye was 6.3%, 3.0% and 1.2%, respectively. The prevalence of myopia was 5.0% (84/1675, 95% CI, 4.8%-5.4%) and of hyperopia was 1.6% (27/1675, 95% CI, 1.0%-2.2%). Astigmatism was evident in 2.0% of the subjects. Myopia increased with increasing age, whereas hyperopia and astigmatism were associated with younger age. Myopia, hyperopia and astigmatism were more common in females. We also found that prevalence of refractive error were associated with education. Myopia and astigmatism were more common in those with higher degrees of education. This report has provided details of the refractive status in a rural school-aged population. Although the prevalence of refractive errors is lower in the population, the unmet need for spectacle correction remains a significant challenge for refractive eye-care services. © 2013 Royal Australian and New Zealand College of Ophthalmologists.

  4. Refractive and corneal astigmatism in white school children in northern ireland.

    PubMed

    O'Donoghue, Lisa; Rudnicka, Alicja R; McClelland, Julie F; Logan, Nicola S; Owen, Christopher G; Saunders, Kathryn J

    2011-06-08

    To study the prevalence of and relation between refractive and corneal astigmatism in white school children in Northern Ireland and to describe the association between refractive astigmatism and refractive error. Stratified random clustering was used to recruit 1053 white children, 392 aged 6-7 years and 661 aged 12-13 years. Eye examinations included cycloplegic autorefraction and ocular biometric measures of axial length and corneal curvature. The prevalence of refractive astigmatism (≥ 1 DC) did not differ significantly between 6- to 7-year-old children (24%; 95% confidence interval [CI], 19-30) and 12- to 13-year-old children (20%; 95% CI, 14-25). The prevalence of corneal astigmatism (≥ 1 DC) also did not differ significantly between 6- to 7-year-old children (29%; 95% CI, 24-34) and 12- to 13-year-old children (25%; 95% CI, 21-28). While levels of refractive astigmatism and corneal astigmatism were similar, refractive astigmatism was predominantly oblique (76%; 95% CI, 67-85, of 6- to 7-year-olds; 59%; 95% CI, 48-70, of 12- to 13-year-olds), but corneal astigmatism was predominantly with-the-rule (80%; 95% CI, 72-87, of 6- to 7-year-olds; 82%; 95% CI, 74-90, of 12- to 13-year-olds). The prevalence of refractive astigmatism was associated with increasing myopia and hyperopia. This study is the first to provide robust population-based data on the prevalence of astigmatism in white school children in the United Kingdom. The prevalence of refractive astigmatism and corneal astigmatism is stable between 6 and 7 years and 12 and 13 years, although this finding would need to be confirmed by prospective studies. There is a high prevalence of refractive and corneal astigmatism which is associated with ametropia.

  5. Refractive errors, visual impairment, and the use of low-vision devices in albinism in Malawi.

    PubMed

    Schulze Schwering, M; Kumar, N; Bohrmann, D; Msukwa, G; Kalua, K; Kayange, P; Spitzer, M S

    2015-04-01

    This study focuses on the refractive implications of albinism in Malawi, which is mostly associated with the burden of visual impairment. The main goal was to describe the refractive errors and to analyze whether patients with albinism in Malawi, Sub-Saharan Africa, benefit from refraction. Age, sex, refractive data, uncorrected and best-corrected visual acuity (UCVA, BCVA), colour vision, contrast sensitivity, and the prescription of sunglasses and low vision devices were collected for a group of 120 albino individuals with oculocutaneous albinism (OCA). Refractive errors were evaluated objectively and subjectively by retinoscopy, and followed by cycloplegic refraction to reconfirm the results. Best-corrected visual acuity (BCVA) was also assessed binocularly. One hundred and twenty albino subjects were examined, ranging in age from 4 to 25 years (median 12 years), 71 (59 %) boys and 49 (41 %) girls. All exhibited horizontal pendular nystagmus. Mean visual acuity improved from 0.98 (0.33) logMAR to 0.77 (0.15) logMAR after refraction (p < 0.001). The best improvement of VA was achieved in patients with mild to moderate myopia. Patients with albinism who were hyperopic more than +1.5 D hardly improved from refraction. With the rule (WTR) astigmatism was more present (37.5 %) than against the rule (ATR) astigmatism (3.8 %). Patients with astigmatism less than 1.5 D improved in 15/32 of cases (47 %) by 2 lines or more. Patients with astigmatism equal to or more than 1.5 D in any axis improved in 26/54 of cases (48 %) by 2 lines or more. Refraction improves visual acuity of children with oculocutaneous albinism in a Sub-Saharan African population in Malawi. The mean improvement was 2 logMAR units.

  6. Controlling soliton refraction in optical lattices.

    PubMed

    Prilepsky, Jaroslaw E; Derevyanko, Stanislav A; Gredeskul, Sergey A

    2011-08-19

    We show in the framework of the 1D nonlinear Schrödinger equation that the value of the refraction angle of a fundamental soliton beam passing through an optical lattice can be controlled by adjusting either the shape of an individual waveguide or the relative positions of the waveguides. In the case of the shallow refractive index modulation, we develop a general approach for the calculation of the refraction angle change. The shape of a single waveguide crucially affects the refraction direction due to the appearance of a structural form factor in the expression for the density of emitted waves. For a lattice of scatterers, wave-soliton interference inside the lattice leads to the appearance of an additional geometric form factor. As a result, the soliton refraction is more pronounced for the disordered lattices than for the periodic ones. © 2011 American Physical Society

  7. Low-Coherence Reflectometry for Refractive Index Measurements of Cells in Micro-Capillaries.

    PubMed

    Carpignano, Francesca; Rigamonti, Giulia; Mazzini, Giuliano; Merlo, Sabina

    2016-10-11

    The refractive index of cells provides insights into their composition, organization and function. Moreover, a good knowledge of the cell refractive index would allow an improvement of optical cytometric and diagnostic systems. Although interferometric techniques undoubtedly represent a good solution for quantifying optical path variation, obtaining the refractive index of a population of cells non-invasively remains challenging because of the variability in the geometrical thickness of the sample. In this paper, we demonstrate the use of infrared low-coherence reflectometry for non-invasively quantifying the average refractive index of cell populations gently confined in rectangular glass micro-capillaries. A suspension of human red blood cells in plasma is tested as a reference. As a use example, we apply this technique to estimate the average refractive index of cell populations belonging to epithelial and hematological families.

  8. High Sensitivity Refractive Index Sensor Based on Dual-Core Photonic Crystal Fiber with Hexagonal Lattice.

    PubMed

    Wang, Haiyang; Yan, Xin; Li, Shuguang; An, Guowen; Zhang, Xuenan

    2016-10-08

    A refractive index sensor based on dual-core photonic crystal fiber (PCF) with hexagonal lattice is proposed. The effects of geometrical parameters of the PCF on performances of the sensor are investigated by using the finite element method (FEM). Two fiber cores are separated by two air holes filled with the analyte whose refractive index is in the range of 1.33-1.41. Numerical simulation results show that the highest sensitivity can be up to 22,983 nm/RIU(refractive index unit) when the analyte refractive index is 1.41. The lowest sensitivity can reach to 21,679 nm/RIU when the analyte refractive index is 1.33. The sensor we proposed has significant advantages in the field of biomolecule detection as it provides a wide-range of detection with high sensitivity.

  9. Refractive index measurement for biomaterial samples by total internal reflection.

    PubMed

    Jin, Y L; Chen, J Y; Xu, L; Wang, P N

    2006-10-21

    The refractive index of biological tissue is a fundamental parameter in applications of optical diagnosis and laser treatments. In the present work, the refractive indices and thermo-optic coefficients of some basic biomaterials, such as blood plasma, haemoglobin solution and lipid membrane, were studied by the method of total internal reflection at the wavelengths of 532 and 632.8 nm that are the most frequently used laser wavelengths in the biomedical field. The effects of the sample concentration and the temperature on refractive index were measured, and empirical relationships were summarized, accompanied by a theoretical explanation based on molecular polarization theory. The results provide some fundamental data for the refractive indices of these biomaterials under variant conditions, and also demonstrate that the total internal reflection method is a feasible and reliable way to measure the refractive indices of biological samples.

  10. Retinal Image Simulation of Subjective Refraction Techniques.

    PubMed

    Perches, Sara; Collados, M Victoria; Ares, Jorge

    2016-01-01

    Refraction techniques make it possible to determine the most appropriate sphero-cylindrical lens prescription to achieve the best possible visual quality. Among these techniques, subjective refraction (i.e., patient's response-guided refraction) is the most commonly used approach. In this context, this paper's main goal is to present a simulation software that implements in a virtual manner various subjective-refraction techniques--including Jackson's Cross-Cylinder test (JCC)--relying all on the observation of computer-generated retinal images. This software has also been used to evaluate visual quality when the JCC test is performed in multifocal-contact-lens wearers. The results reveal this software's usefulness to simulate the retinal image quality that a particular visual compensation provides. Moreover, it can help to gain a deeper insight and to improve existing refraction techniques and it can be used for simulated training.

  11. High Sensitivity Refractive Index Sensor Based on Dual-Core Photonic Crystal Fiber with Hexagonal Lattice

    PubMed Central

    Wang, Haiyang; Yan, Xin; Li, Shuguang; An, Guowen; Zhang, Xuenan

    2016-01-01

    A refractive index sensor based on dual-core photonic crystal fiber (PCF) with hexagonal lattice is proposed. The effects of geometrical parameters of the PCF on performances of the sensor are investigated by using the finite element method (FEM). Two fiber cores are separated by two air holes filled with the analyte whose refractive index is in the range of 1.33–1.41. Numerical simulation results show that the highest sensitivity can be up to 22,983 nm/RIU(refractive index unit) when the analyte refractive index is 1.41. The lowest sensitivity can reach to 21,679 nm/RIU when the analyte refractive index is 1.33. The sensor we proposed has significant advantages in the field of biomolecule detection as it provides a wide-range of detection with high sensitivity. PMID:27740607

  12. Low-Coherence Reflectometry for Refractive Index Measurements of Cells in Micro-Capillaries

    PubMed Central

    Carpignano, Francesca; Rigamonti, Giulia; Mazzini, Giuliano; Merlo, Sabina

    2016-01-01

    The refractive index of cells provides insights into their composition, organization and function. Moreover, a good knowledge of the cell refractive index would allow an improvement of optical cytometric and diagnostic systems. Although interferometric techniques undoubtedly represent a good solution for quantifying optical path variation, obtaining the refractive index of a population of cells non-invasively remains challenging because of the variability in the geometrical thickness of the sample. In this paper, we demonstrate the use of infrared low-coherence reflectometry for non-invasively quantifying the average refractive index of cell populations gently confined in rectangular glass micro-capillaries. A suspension of human red blood cells in plasma is tested as a reference. As a use example, we apply this technique to estimate the average refractive index of cell populations belonging to epithelial and hematological families. PMID:27727172

  13. Stabilization in early adult-onset myopia with corneal refractive therapy.

    PubMed

    González-Méijome, José M; Carracedo, Gonzalo; Lopes-Ferreira, Daniela; Faria-Ribeiro, Miguel A; Peixoto-de-Matos, Sofia C; Queirós, António

    2016-02-01

    To describe the stabilization of early adult-onset myopia in three university students after initiating orthokeratology treatment with corneal refractive therapy contact lenses. Three Caucasian early adult-onset progressing myopic subjects (1 male, 2 females) were fitted with corneal refractive therapy lenses to correct myopia between -1.50 and -2.50 D of sphere using Paragon CRT (Paragon Vision Sciences, Mesa, AZ) lenses for overnight orthokeratology. The pre-treatment refractive history from 2005 as well as refraction and axial length after treatment onset are reported over a period of 3 years between December 2009 and January 2013 with an additional year of follow-up after treatment discontinuation (January-December 2013). The peripheral refractive patterns and topographic changes are also reported individually. Treatment was successful in all three subjects achieving uncorrected visual acuity of 20/20 or better monocularly. During a period of 3 years of follow-up the subjects did not experience progression in their refractive error, nor in their axial length (measured during the last 2 years of treatment and 1 year after discontinuation). Furthermore, the subjects recovered to their baseline refraction and did not progressed further over the following year after lens wear discontinuation. We cannot attribute a causative effect to the orthokeratology treatment alone as underlying mechanism for myopia stabilization in this 3 patients. However, the present report points to the possibility of stabilization of early adult-onset myopia progression in young adults using corneal refractive therapy treatment. Copyright © 2015 Elsevier Ltd. All rights reserved.

  14. Analysis of the hologram recording on the novel chloride photo-thermo-refractive glass

    NASA Astrophysics Data System (ADS)

    Ivanov, S. A.; Nikonorov, N. V.; Dubrovin, V. D.; Krykova, V. A.

    2017-05-01

    In this research, we present new holographic material based on fluoride photo-thermo-refractive glass(PTR) - chloride PTR glass. One of the benefit of this type of PTR glass is positive refractive index change. During this work, for the first-time volume Bragg gratings were recorded in this kind of material. The first experiments revealed that such gratings are mixed i.e. possess both absorption and phase components. Complex analysis shows that both refractive index and absorption coefficient are modulated inside the grating structure. We found out that at first there is no strict dependence of the refractive index change from dosage, but as we continue the process of thermal treatment - dependence is appear. Exposure influence on the refractive index change for this glass differs from fluoride one and shows some sort of saturation after the exposure of 4-6 J/cm2 . We distinguished refractive index change and absorption coefficient change and observed both behavior with increasing thermal treatment time. We found out that the increase of thermal treatment time results in the significant refractive index change. At the same time the absorption does `not practically change. It was found that maximum modulation of refractive index is comparable with fluoride PTR glass and achieves value of 1600 ppm. The modulation of absorption is equal to induced absorption caused by silver nanoparticles and depends from reading wavelength. Our study shows that almost all absorption is modulated inside the grating.

  15. The effect of procedure room temperature and humidity on LASIK outcomes.

    PubMed

    Seider, Michael I; McLeod, Stephen D; Porco, Travis C; Schallhorn, Steven C

    2013-11-01

    To determine whether procedure room temperature or humidity during LASIK affect refractive outcomes in a large patient sample. Retrospective cohort study. A total of 202 394 eyes of 105 712 patients aged 18 to 75 years who underwent LASIK at an Optical Express, Inc., location in their United Kingdom and Ireland centers from January 1, 2008, to June 30, 2011, who met inclusion criteria. Patient age, gender, flap creation technique, pre- and 1-month post-LASIK manifest refraction, and ambient temperature and humidity during LASIK were recorded. Effect size determination and univariate and multivariate analyses were performed to characterize the relationships between LASIK procedure room temperature and humidity and postoperative refractive outcome. One month post-LASIK manifest refraction. No clinically significant effect of procedure room temperature or humidity was found on LASIK refractive outcomes. When considering all eyes in our population, an increase of 1°C during LASIK was associated with a 0.003 diopter (D) more hyperopic refraction 1 month postoperatively, and an increase in 1% humidity was associated with a 0.0004 more myopic refraction. These effect sizes were the same or similar when considering only myopic eyes, only hyperopic eyes, and subgroups of eyes stratified by age and preoperative refractive error. Neither procedure room temperature nor humidity during LASIK were found to have a clinically significant relationship with postoperative manifest refraction in our population. Copyright © 2013 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  16. The effect of procedure room temperature and humidity on LASIK outcomes

    PubMed Central

    Seider, Michael I.; McLeod, Stephen D.; Porco, Travis C.; Schallhorn, Steven C.

    2013-01-01

    Objective To determine if procedure room temperature and humidity during LASIK affects refractive outcomes in a very large patient sample. Design Retrospective cohort study. Participants 202,394 eyes of 105,712 patients aged 18 to 75 years old who underwent LASIK at an Optical Express, Inc. location in their United Kingdom and Ireland centers from January 1, 2008 to June 30, 2011 who met inclusion criteria. Methods Patient age, gender, pre- and one month post-LASIK manifest refraction and flap creation technique were recorded as well as the ambient temperature and humidity during LASIK. Effect size determination, in addition to univariate and multivariate analysis was performed to characterize the relationships between LASIK procedure room temperature and humidity and post-operative refractive outcome. Main Outcome Measures One month post-LASIK manifest refraction. Results No clinically significant effect of procedure room temperature or humidity was found on LASIK refractive outcomes. When considering all eyes in our population, an increase of one degree Celsius during LASIK was associated with a 0.003 diopter more hyperopic refraction one month post-operatively and an increase in one percent humidity was associated with a 0.0004 more myopic refraction. These effect sizes were the same or similar when considering only myopic eyes, only hyperopic eyes and subgroups of eyes stratified by age and pre-operative refractive error. Conclusions Procedure room temperature or humidity during LASIK was found to have no clinically significant relationship with post-operative manifest refraction in our population. PMID:23769199

  17. Nature and Nurture: the complex genetics of myopia and refractive error

    PubMed Central

    Wojciechowski, Robert

    2010-01-01

    The refractive errors, myopia and hyperopia, are optical defects of the visual system that can cause blurred vision. Uncorrected refractive errors are the most common causes of visual impairment worldwide. It is estimated that 2.5 billion people will be affected by myopia alone with in the next decade. Experimental, epidemiological and clinical research has shown that refractive development is influenced by both environmental and genetic factors. Animal models have demonstrated that eye growth and refractive maturation during infancy are tightly regulated by visually-guided mechanisms. Observational data in human populations provide compelling evidence that environmental influences and individual behavioral factors play crucial roles in myopia susceptibility. Nevertheless, the majority of the variance of refractive error within populations is thought to be due to hereditary factors. Genetic linkage studies have mapped two dozen loci, while association studies have implicated more than 25 different genes in refractive variation. Many of these genes are involved in common biological pathways known to mediate extracellular matrix composition and regulate connective tissue remodeling. Other associated genomic regions suggest novel mechanisms in the etiology of human myopia, such as mitochondrial-mediated cell death or photoreceptor-mediated visual signal transmission. Taken together, observational and experimental studies have revealed the complex nature of human refractive variation, which likely involves variants in several genes and functional pathways. Multiway interactions between genes and/or environmental factors may also be important in determining individual risks of myopia, and may help explain the complex pattern of refractive error in human populations. PMID:21155761

  18. Refractive index measurement based on confocal method

    NASA Astrophysics Data System (ADS)

    An, Zhe; Xu, XiPing; Yang, JinHua; Qiao, Yang; Liu, Yang

    2017-10-01

    The development of transparent materials is closed to optoelectronic technology. It plays an increasingly important role in various fields. It is not only widely used in optical lens, optical element, optical fiber grating, optoelectronics, but also widely used in the building material, pharmaceutical industry with vessel, aircraft windshield and daily wear glasses.Regard of solving the problem of refractive index measurement in optical transparent materials. We proposed that using the polychromatic confocal method to measuring the refractive index of transparent materials. In this article, we describes the principle of polychromatic confocal method for measuring the refractive index of glass,and sketched the optical system and its optimization. Then we establish the measurement model of the refractive index, and set up the experimental system. In this way, the refractive index of the glass has been calibrated for refractive index experiment. Due to the error in the experimental process, we manipulated the experiment data to compensate the refractive index measurement formula. The experiment taking the quartz glass for instance. The measurement accuracy of the refractive index of the glass is +/-1.8×10-5. This method is more practical and accurate, especially suitable for non-contact measurement occasions, which environmental requirements is not high. Environmental requirements are not high, the ordinary glass production line up to the ambient temperature can be fully adapted. There is no need for the color of the measured object that you can measure the white and a variety of colored glass.

  19. Refractive indices used by the Haag-Streit Lenstar to calculate axial biometric dimensions.

    PubMed

    Suheimat, Marwan; Verkicharla, Pavan K; Mallen, Edward A H; Rozema, Jos J; Atchison, David A

    2015-01-01

    To estimate refractive indices used by the Lenstar biometer to translate measured optical path lengths into geometrical path lengths within the eye. Axial lengths of model eyes were determined using the IOLMaster and Lenstar biometers; comparing those lengths gave an overall eye refractive index estimate for the Lenstar. Using the Lenstar Graphical User Interface, we noticed that boundaries between media could be manipulated and opposite changes in optical path lengths on either side of the boundary could be introduced. Those ratios were combined with the overall eye refractive index to estimate separate refractive indices. Furthermore, Haag-Streit provided us with a template to obtain 'air thicknesses' to compare with geometrical distances. The axial length estimates obtained using the IOLMaster and the Lenstar agreed to within 0.01 mm. Estimates of group refractive indices used in the Lenstar were 1.340, 1.341, 1.415, and 1.354 for cornea, aqueous, lens, and overall eye, respectively. Those refractive indices did not match those of schematic eyes, but were close in the cases of aqueous and lens. Linear equations relating air thicknesses to geometrical thicknesses were consistent with our findings. The Lenstar uses different refractive indices for different ocular media. Some of the refractive indices, such as that for the cornea, are not physiological; therefore, it is likely that the calibrations in the instrument correspond to instrument-specific corrections and are not the real optical path lengths. © 2014 The Authors Ophthalmic & Physiological Optics © 2014 The College of Optometrists.

  20. Determination of refractive index of a simple negative, positive, or zero power lens using wedged plated interferometer

    NASA Technical Reports Server (NTRS)

    Shukla, R. P.; Perera, G. M.; George, M. C.; Venkateswarlu, P.

    1990-01-01

    A nondestructive technique for measuring the refractive index of a negative lens using a wedged plate interferometer is described. The method can be also used for measuring the refractive index of convex or zero power lenses. Schematic diagrams are presented for the use of a wedged plate interferometer for measuring the refractive index of a concave lens and of a convex lens.

  1. Refractive-index profiling of embedded microstructures in optical materials

    NASA Astrophysics Data System (ADS)

    Dave, Digant P.; Milner, Thomas E.

    2002-04-01

    We describe use of a phase-sensitive low-coherence reflectometer to measure spatial variation of refractive index in optical materials. The described interferometric technique is demonstrated to be a valuable tool to profile the refractive index of optical elements such as integrated waveguides and photowritten optical microstructures. As an example, a refractive-index profile is mapped of a microstructure written in a microscope glass slide with an ultrashort-pulse laser.

  2. Determination of refractive index, size, and concentration of nonabsorbing colloidal nanoparticles from measurements of the complex effective refractive index.

    PubMed

    Márquez-Islas, Roberto; Sánchez-Pérez, Celia; García-Valenzuela, Augusto

    2014-02-01

    We describe a method for obtaining the refractive index (RI), size, and concentration of nonabsorbing nanoparticles in suspension from relatively simple optical measurements. The method requires measuring the complex effective RI of two dilute suspensions of the particles in liquids of different refractive indices. We describe the theoretical basis of the proposed method and provide experimental results validating the procedure.

  3. Refractivity variations and propagation at Ultra High Frequency

    NASA Astrophysics Data System (ADS)

    Alam, I.; Najam-Ul-Islam, M.; Mujahid, U.; Shah, S. A. A.; Ul Haq, Rizwan

    Present framework is established to deal with the refractivity variations normally affected the radio waves propagation at different frequencies, ranges and different environments. To deal such kind of effects, many researchers proposed several methodologies. One method is to use the parameters from meteorology to investigate these effects of variations in refractivity on propagation. These variations are region specific and we have selected a region of one kilometer height over the English Channel. We have constructed different modified refractivity profiles based on the local meteorological data. We have recorded more than 48 million received signal strength from a communication links of 50 km operating at 2015 MHz in the Ultra High Frequency band giving path loss between transmitting and receiving stations of the experimental setup. We have used parabolic wave equation method to simulate an hourly value of signal strength and compared the obtained simulated loss to the experimental loss. The analysis is made to compute refractivity distribution of standard (STD) and ITU (International Telecommunication Union) refractivity profiles for various evaporation ducts. It is found that a standard refractivity profile is better than the ITU refractivity profiles for the region at 2015 MHz. Further, it is inferred from the analysis of results that 10 m evaporation duct height is the dominant among all evaporation duct heights considered in the research.

  4. Surgical Options for the Refractive Correction of Keratoconus: Myth or Reality

    PubMed Central

    Zaldivar, R.; Aiello, F.; Madrid-Costa, D.

    2017-01-01

    Keratoconus provides a decrease of quality of life to the patients who suffer from it. The treatment used as well as the method to correct the refractive error of these patients may influence on the impact of the disease on their quality of life. The purpose of this review is to describe the evidence about the conservative surgical treatment for keratoconus aiming to therapeutic and refractive effect. The visual rehabilitation for keratoconic corneas requires addressing three concerns: halting the ectatic process, improving corneal shape, and minimizing the residual refractive error. Cross-linking can halt the disease progression, intrastromal corneal ring segments can improve the corneal shape and hence the visual quality and reduce the refractive error, PRK can correct mild-moderate refractive error, and intraocular lenses can correct from low to high refractive error associated with keratoconus. Any of these surgical options can be performed alone or combined with the other techniques depending on what the case requires. Although it could be considered that the surgical option for the refracto-therapeutic treatment of the keratoconus is a reality, controlled, randomized studies with larger cohorts and longer follow-up periods are needed to determine which refractive procedure and/or sequence are most suitable for each case. PMID:29403662

  5. Prevalence of refractive errors in the European adult population: the Gutenberg Health Study (GHS).

    PubMed

    Wolfram, Christian; Höhn, René; Kottler, Ulrike; Wild, Philipp; Blettner, Maria; Bühren, Jens; Pfeiffer, Norbert; Mirshahi, Alireza

    2014-07-01

    To study the distribution of refractive errors among adults of European descent. Population-based eye study in Germany with 15010 participants aged 35-74 years. The study participants underwent a detailed ophthalmic examination according to a standardised protocol. Refractive error was determined by an automatic refraction device (Humphrey HARK 599) without cycloplegia. Definitions for the analysis were myopia <-0.5 dioptres (D), hyperopia >+0.5 D, astigmatism >0.5 cylinder D and anisometropia >1.0 D difference in the spherical equivalent between the eyes. Exclusion criterion was previous cataract or refractive surgery. 13959 subjects were eligible. Refractive errors ranged from -21.5 to +13.88 D. Myopia was present in 35.1% of this study sample, hyperopia in 31.8%, astigmatism in 32.3% and anisometropia in 13.5%. The prevalence of myopia decreased, while the prevalence of hyperopia, astigmatism and anisometropia increased with age. 3.5% of the study sample had no refractive correction for their ametropia. Refractive errors affect the majority of the population. The Gutenberg Health Study sample contains more myopes than other study cohorts in adult populations. Our findings do not support the hypothesis of a generally lower prevalence of myopia among adults in Europe as compared with East Asia.

  6. [A study of refractive errors in a primary school in Cotonou, Benin].

    PubMed

    Sounouvou, I; Tchabi, S; Doutetien, C; Sonon, F; Yehouessi, L; Bassabi, S K

    2008-10-01

    Determine the epidemiologic aspects and the degree of severity of different refractive errors in primary schoolchildren. A prospective and descriptive study was conducted from 1 December 2005 to 31 March 2006 on schoolchildren ranging from 4 to 16 years of age in a public primary school in Cotonou, Benin. The refraction was evaluated for any visual acuity lower than or equal to 0.7. The study included 1057 schoolchildren. The average age of the study population was 8.5+/-2.6 years with a slight predominance of females (51.8%). The prevalence of refractive error was 10.6% and astigmatism accounted for the most frequent refractive anomaly (91.9%). Myopia and the hyperopia were associated with astigmatism in 29.4% and 16.1% of the cases, respectively. The age bracket from 6 to 11 years accounted for the majority of refractive errors (75.9%), without age and sex being risk factors (p=0.811 and p=0.321, respectively). The average vision of the ametropic eye was 0.61, with a clear predominance of slight refractive errors (89.3%) and particularly of low-level simple astigmatism (45.5%). The relatively low prevalence of refractive error observed does not obviate the need for implementing actions to improve the ocular health of schoolchildren.

  7. Uncorrected refractive errors

    PubMed Central

    Naidoo, Kovin S; Jaggernath, Jyoti

    2012-01-01

    Global estimates indicate that more than 2.3 billion people in the world suffer from poor vision due to refractive error; of which 670 million people are considered visually impaired because they do not have access to corrective treatment. Refractive errors, if uncorrected, results in an impaired quality of life for millions of people worldwide, irrespective of their age, sex and ethnicity. Over the past decade, a series of studies using a survey methodology, referred to as Refractive Error Study in Children (RESC), were performed in populations with different ethnic origins and cultural settings. These studies confirmed that the prevalence of uncorrected refractive errors is considerably high for children in low-and-middle-income countries. Furthermore, uncorrected refractive error has been noted to have extensive social and economic impacts, such as limiting educational and employment opportunities of economically active persons, healthy individuals and communities. The key public health challenges presented by uncorrected refractive errors, the leading cause of vision impairment across the world, require urgent attention. To address these issues, it is critical to focus on the development of human resources and sustainable methods of service delivery. This paper discusses three core pillars to addressing the challenges posed by uncorrected refractive errors: Human Resource (HR) Development, Service Development and Social Entrepreneurship. PMID:22944755

  8. Plate refractive camera model and its applications

    NASA Astrophysics Data System (ADS)

    Huang, Longxiang; Zhao, Xu; Cai, Shen; Liu, Yuncai

    2017-03-01

    In real applications, a pinhole camera capturing objects through a planar parallel transparent plate is frequently employed. Due to the refractive effects of the plate, such an imaging system does not comply with the conventional pinhole camera model. Although the system is ubiquitous, it has not been thoroughly studied. This paper aims at presenting a simple virtual camera model, called a plate refractive camera model, which has a form similar to a pinhole camera model and can efficiently model refractions through a plate. The key idea is to employ a pixel-wise viewpoint concept to encode the refraction effects into a pixel-wise pinhole camera model. The proposed camera model realizes an efficient forward projection computation method and has some advantages in applications. First, the model can help to compute the caustic surface to represent the changes of the camera viewpoints. Second, the model has strengths in analyzing and rectifying the image caustic distortion caused by the plate refraction effects. Third, the model can be used to calibrate the camera's intrinsic parameters without removing the plate. Last but not least, the model contributes to putting forward the plate refractive triangulation methods in order to solve the plate refractive triangulation problem easily in multiviews. We verify our theory in both synthetic and real experiments.

  9. Theory, design, and experimental verification of a reflectionless bianisotropic Huygens' metasurface for wide-angle refraction

    NASA Astrophysics Data System (ADS)

    Chen, Michael; Abdo-Sánchez, Elena; Epstein, Ariel; Eleftheriades, George V.

    2018-03-01

    Huygens' metasurfaces are electrically thin devices which allow arbitrary field transformations. Beam refraction is among the first demonstrations of realized metasurfaces. As previously shown for extreme-angle refraction, control over only the electric impedance and magnetic admittance of the Huygens' metasurface proved insufficient to produce the desired reflectionless field transformation. To maintain zero reflections for wide refraction angles, magnetoelectric coupling between the electric and magnetic response of the metasurface, leading to bianisotropy, can be introduced. In this paper, we report the theory, design, and experimental characterization of a reflectionless bianisotropic metasurface for extreme-angle refraction of a normally incident plane wave towards 71.8° at 20 GHz. The theory and design of three-layer asymmetric bianisotropic unit cells are discussed. The realized printed circuit board structure was tested via full-wave simulations as well as experimental characterization. To experimentally verify the prototype, two setups were used. A quasi-optical experiment was conducted to assess the specular reflections of the metasurface, while a far-field antenna measurement characterized its refraction nature. The measurements verify that the fabricated metasurface has negligible reflections and the majority of the scattered power is refracted to the desired Floquet mode. This provides an experimental demonstration of a reflectionless wide-angle refracting metasurface using a bianisotropic Huygens' metasurface at microwave frequencies.

  10. Peripheral refractive correction and automated perimetric profiles.

    PubMed

    Wild, J M; Wood, J M; Crews, S J

    1988-06-01

    The effect of peripheral refractive error correction on the automated perimetric sensitivity profile was investigated on a sample of 10 clinically normal, experienced observers. Peripheral refractive error was determined at eccentricities of 0 degree, 20 degrees and 40 degrees along the temporal meridian of the right eye using the Canon Autoref R-1, an infra-red automated refractor, under the parametric conditions of the Octopus automated perimeter. Perimetric sensitivity was then undertaken at these eccentricities (stimulus sizes 0 and III) with and without the appropriate peripheral refractive correction using the Octopus 201 automated perimeter. Within the measurement limits of the experimental procedures employed, perimetric sensitivity was not influenced by peripheral refractive correction.

  11. Refractive index of plant cell walls

    NASA Technical Reports Server (NTRS)

    Gausman, H. W.; Allen, W. A.; Escobar, D. E.

    1974-01-01

    Air was replaced with media of higher refractive indices by vacuum infiltration in leaves of cucumber, blackeye pea, tomato, and string bean plants, and reflectance of noninfiltrated and infiltrated leaves was spectrophotometrically measured. Infiltrated leaves reflected less light than noninfiltrated leaves over the 500-2500-nm wavelength interval because cell wall-air interfaces were partly eliminated. Minimal reflectance should occur when the average refractive index of plant cell walls was matched by the infiltrating fluid. Although refractive indices that resulted in minimal reflectance differed among the four plant genera, an average value of 1.425 approximates the refractive index of plant cell walls for the four plant genera.

  12. Atmospheric refraction: a history.

    PubMed

    Lehn, Waldemar H; van der Werf, Siebren

    2005-09-20

    We trace the history of atmospheric refraction from the ancient Greeks up to the time of Kepler. The concept that the atmosphere could refract light entered Western science in the second century B.C. Ptolemy, 300 years later, produced the first clearly defined atmospheric model, containing air of uniform density up to a sharp upper transition to the ether, at which the refraction occurred. Alhazen and Witelo transmitted his knowledge to medieval Europe. The first accurate measurements were made by Tycho Brahe in the 16th century. Finally, Kepler, who was aware of unusually strong refractions, used the Ptolemaic model to explain the first documented and recognized mirage (the Novaya Zemlya effect).

  13. Quantitative estimation of film forming polymer-plasticizer interactions by the Lorentz-Lorenz Law.

    PubMed

    Dredán, J; Zelkó, R; Dávid, A Z; Antal, I

    2006-03-09

    Molar refraction as well as refractive index has many uses. Beyond confirming the identity and purity of a compound, determination of molecular structure and molecular weight, molar refraction is also used in other estimation schemes, such as in critical properties, surface tension, solubility parameter, molecular polarizability, dipole moment, etc. In the present study molar refraction values of polymer dispersions were determined for the quantitative estimation of film forming polymer-plasticizer interactions. Information can be obtained concerning the extent of interaction between the polymer and the plasticizer from the calculation of molar refraction values of film forming polymer dispersions containing plasticizer.

  14. A refractive index sensor based on taper Michelson interferometer in multimode fiber

    NASA Astrophysics Data System (ADS)

    Fu, Xinghu; Zhang, Jiangpeng; Wang, Siwen; Fu, Guangwei; Liu, Qiang; Jin, Wa; Bi, Weihong

    2016-11-01

    A refractive index sensor based on taper Michelson interferometer in multimode fiber is proposed. The Hydrofluoric acid corrosion processing is studied in the preparation of single cone multimode optical fiber sensor. The taper Michelson interferometer is fabricated by changing corrosion time. The relationship between fiber sensor feature and corrosion time is analyzed. The experimental results show that the interference spectrum shift in the direction of short wave with the increase of the refractive index. The refractive index sensitivity can reach 115.8008 nm/RIU. Thereby, it can be used in detecting the refractive index in different areas including the environmental protection, health care and food production.

  15. Experimental verification and simulation of negative index of refraction using Snell's law.

    PubMed

    Parazzoli, C G; Greegor, R B; Li, K; Koltenbah, B E C; Tanielian, M

    2003-03-14

    We report the results of a Snell's law experiment on a negative index of refraction material in free space from 12.6 to 13.2 GHz. Numerical simulations using Maxwell's equations solvers show good agreement with the experimental results, confirming the existence of negative index of refraction materials. The index of refraction is a function of frequency. At 12.6 GHz we measure and compute the real part of the index of refraction to be -1.05. The measurements and simulations of the electromagnetic field profiles were performed at distances of 14lambda and 28lambda from the sample; the fields were also computed at 100lambda.

  16. Numerical simulations of negative-index refraction in wedge-shaped metamaterials.

    PubMed

    Dong, Z G; Zhu, S N; Liu, H; Zhu, J; Cao, W

    2005-07-01

    A wedge-shaped structure made of split-ring resonators (SRR) and wires is numerically simulated to evaluate its refraction behavior. Four frequency bands, namely, the stop band, left-handed band, ultralow-index band, and positive-index band, are distinguished according to the refracted field distributions. Negative phase velocity inside the wedge is demonstrated in the left-handed band and the Snell's Law is conformed in terms of its refraction behaviors in different frequency bands. Our results confirmed that negative index of refraction indeed exists in such a composite metamaterial and also provided a convincing support to the results of previous Snell's Law experiments.

  17. Polymer microfiber bridging Bi-tapered refractive index sensor based on evanescent field

    NASA Astrophysics Data System (ADS)

    Lv, Ri-Qing; Wang, Qi; Wang, Bo-Tao; Liu, Yu; Kong, Lingxin

    2018-05-01

    A PDMS/graphene enhanced PMMA micro optical waveguide sensor is reported in terms of fabrication method and optical characteristics. The micro optical waveguide with a diameter of 6 μm and a length of 800 μm is used as the sensing probe to realize refractive index (RI) measurement suspended in NaCl solutions with different concentrations. Experimental results show that the refractive index sensing sensitivity can reach 2027.97 nm/RIU within the refractive index ranging from 1.3333-1.3426. Research results show that PMMA/graphene micro optical waveguide doped with PDMS is an excellent high sensitive sensing technology in refractive index detection field.

  18. Highly sensitive refractive index fiber inline Mach-Zehnder interferometer fabricated by femtosecond laser micromachining and chemical etching

    NASA Astrophysics Data System (ADS)

    Sun, Xiao-Yan; Chu, Dong-Kai; Dong, Xin-Ran; Zhou, Chu; Li, Hai-Tao; Luo-Zhi; Hu, You-Wang; Zhou, Jian-Ying; Cong-Wang; Duan, Ji-An

    2016-03-01

    A High sensitive refractive index (RI) sensor based on Mach-Zehnder interferometer (MZI) in a conventional single-mode optical fiber is proposed, which is fabricated by femtosecond laser transversal-scanning inscription method and chemical etching. A rectangular cavity structure is formed in part of fiber core and cladding interface. The MZI sensor shows excellent refractive index sensitivity and linearity, which exhibits an extremely high RI sensitivity of -17197 nm/RIU (refractive index unit) with the linearity of 0.9996 within the refractive index range of 1.3371-1.3407. The experimental results are consistent with theoretical analysis.

  19. Applications of the JARS method to study levee sites in southern Texas and southern New Mexico

    USGS Publications Warehouse

    Ivanov, J.; Miller, R.D.; Xia, J.; Dunbar, J.B.

    2007-01-01

    We apply the joint analysis of refractions with surface waves (JARS) method to several sites and compare its results to traditional refraction-tomography methods in efforts of finding a more realistic solution to the inverse refraction-traveltime problem. The JARS method uses a reference model, derived from surface-wave shear-wave velocity estimates, as a constraint. In all of the cases JARS estimates appear more realistic than those from the conventional refraction-tomography methods. As a result, we consider, the JARS algorithm as the preferred method for finding solutions to the inverse refraction-tomography problems. ?? 2007 Society of Exploration Geophysicists.

  20. Investigation of the refractive index repeatability for tantalum pentoxide coatings, prepared by physical vapor film deposition techniques.

    PubMed

    Stenzel, O; Wilbrandt, S; Wolf, J; Schürmann, M; Kaiser, N; Ristau, D; Ehlers, H; Carstens, F; Schippel, S; Mechold, L; Rauhut, R; Kennedy, M; Bischoff, M; Nowitzki, T; Zöller, A; Hagedorn, H; Reus, H; Hegemann, T; Starke, K; Harhausen, J; Foest, R; Schumacher, J

    2017-02-01

    Random effects in the repeatability of refractive index and absorption edge position of tantalum pentoxide layers prepared by plasma-ion-assisted electron-beam evaporation, ion beam sputtering, and magnetron sputtering are investigated and quantified. Standard deviations in refractive index between 4*10-4 and 4*10-3 have been obtained. Here, lowest standard deviations in refractive index close to our detection threshold could be achieved by both ion beam sputtering and plasma-ion-assisted deposition. In relation to the corresponding mean values, the standard deviations in band-edge position and refractive index are of similar order.

  1. Determination of the refractive index of glucose-ethanol-water mixtures using spectroscopic refractometry near the critical angle.

    PubMed

    Sobral, H; Peña-Gomar, M

    2015-10-01

    A spectroscopic refractometer was used to investigate the dispersion curves of ethanol and D-glucose solutions in water near the critical angle; here, the reflectivity was measured using a white source. Dispersion curves were obtained in the 320-1000 nm wavelength range with a resolution better than 10(-4) for the refractive index, n. The differential refractive index is measured as a function of wavelength, and a simple expression is proposed to obtain the refractive index of the glucose-ethanol-water ternary system. Using this expression, combined with the experimental differential refractive index values, the concentrations of individual components can be calculated.

  2. Precise determination of the refractive index of suspended particles: light transmission as a function of refractive index mismatch

    NASA Astrophysics Data System (ADS)

    McClymer, J. P.

    2016-08-01

    Many fluids appear white because refractive index differences lead to multiple scattering. In this paper, we use safe, low-cost commercial index matching fluids to quantitatively study light transmission as a function of index mismatch, reduce multiple scattering to allow single scattering probes, and to precisely determine the index of refraction of suspended material. The transmission profile is compared with Rayleigh-Gans and Mie theory predictions. The procedure is accessible as a student laboratory project, while providing advantages over other standard methods of measuring the refractive index of an unknown nanoparticle, making it valuable to researchers.

  3. Refractive indices of liquid crystal E7 depending on temperature and wavelengths

    NASA Astrophysics Data System (ADS)

    Ma, Mingjian; Li, Shuguang; Jing, Xili; Chen, Hailiang

    2017-11-01

    The dependence of refractive indices of liquid crystal (LC) on temperature is represented by the Haller approximation model, and its dependence on the wavelength is expressed by the extended Cauchy model. We derived the refractive indices expressions of nematic LC E7 depending on temperature and wavelength simultaneously by combining these two models. Based on the obtained expressions, one can acquire the refractive indices of E7 at arbitrary temperature and wavelengths. The birefringence, variation rate of refractive indices, macroscopic order parameter Q, and orientational order parameter ⟨P2⟩ of E7 were then discussed based on the expressions.

  4. Spatial Frequency Multiplexing of Fiber-Optic Interferometric Refractive Index Sensors Based on Graded-Index Multimode Fibers

    PubMed Central

    Liu, Li; Gong, Yuan; Wu, Yu; Zhao, Tian; Wu, Hui-Juan; Rao, Yun-Jiang

    2012-01-01

    Fiber-optic interferometric sensors based on graded-index multimode fibers have very high refractive-index sensitivity, as we previously demonstrated. In this paper, spatial-frequency multiplexing of this type of fiber-optic refractive index sensors is investigated. It is estimated that multiplexing of more than 10 such sensors is possible. In the multiplexing scheme, one of the sensors is used to investigate the refractive index and temperature responses. The fast Fourier transform (FFT) of the combined reflective spectra is analyzed. The intensity of the FFT spectra is linearly related with the refractive index and is not sensitive to the temperature.

  5. [Reproducibility of subjective refraction measurement].

    PubMed

    Grein, H-J; Schmidt, O; Ritsche, A

    2014-11-01

    Reproducibility of subjective refraction measurement is limited by various factors. The main factors affecting reproducibility include the characteristics of the measurement method and of the subject and the examiner. This article presents the results of a study on this topic, focusing on the reproducibility of subjective refraction measurement in healthy eyes. The results of previous studies are not all presented in the same way by the respective authors and cannot be fully standardized without consulting the original scientific data. To the extent that they are comparable, the results of our study largely correspond largely with those of previous investigations: During repeated subjective refraction measurement, 95% of the deviation from the mean value was approximately ±0.2 D to ±0.65 D for the spherical equivalent and cylindrical power. The reproducibility of subjective refraction measurement in healthy eyes is limited, even under ideal conditions. Correct assessment of refraction results is only feasible after identifying individual variability. Several measurements are required. Refraction cannot be measured without a tolerance range. The English full-text version of this article is available at SpringerLink (under supplemental).

  6. Comparable change in stromal refractive index of cat and human corneas following blue-IRIS.

    PubMed

    Wozniak, Kaitlin T; Gearhart, Sara M; Savage, Daniel E; Ellis, Jonathan D; Knox, Wayne H; Huxlin, Krystel R

    2017-05-01

    Blue intratissue refractive index shaping (blue-IRIS) is a method with potential to correct ocular refraction noninvasively in humans. To date, blue-IRIS has only ever been applied to cat corneas and hydrogels. To test the comparability of refractive index change achievable in cat and human tissues, we used blue-IRIS to write identical phase gratings in ex vivo feline and human corneas. Femtosecond pulses (400 nm) were focused ? 300 ?? ? m below the epithelial surface of excised cat and human corneas and scanned to write phase gratings with lines ? 1 ?? ? m wide, spaced 5 ?? ? m apart, using a scan speed of 5 ?? mm / s . Additional cat corneas were used to test writing at 3 and 7 ?? mm / s in order to document speed dependence of the refractive index change magnitude. The first-order diffraction efficiency was immediately measured and used to calculate the refractive index change attained. Our data show that blue-IRIS induces comparable refractive index changes in feline and human corneas, an essential requirement for further developing its use as a clinical vision correction technique.

  7. Comparable change in stromal refractive index of cat and human corneas following blue-IRIS

    NASA Astrophysics Data System (ADS)

    Wozniak, Kaitlin T.; Gearhart, Sara M.; Savage, Daniel E.; Ellis, Jonathan D.; Knox, Wayne H.; Huxlin, Krystel R.

    2017-05-01

    Blue intratissue refractive index shaping (blue-IRIS) is a method with potential to correct ocular refraction noninvasively in humans. To date, blue-IRIS has only ever been applied to cat corneas and hydrogels. To test the comparability of refractive index change achievable in cat and human tissues, we used blue-IRIS to write identical phase gratings in ex vivo feline and human corneas. Femtosecond pulses (400 nm) were focused ˜300 μm below the epithelial surface of excised cat and human corneas and scanned to write phase gratings with lines ˜1 μm wide, spaced 5 μm apart, using a scan speed of 5 mm/s. Additional cat corneas were used to test writing at 3 and 7 mm/s in order to document speed dependence of the refractive index change magnitude. The first-order diffraction efficiency was immediately measured and used to calculate the refractive index change attained. Our data show that blue-IRIS induces comparable refractive index changes in feline and human corneas, an essential requirement for further developing its use as a clinical vision correction technique.

  8. Laser interferometry of the hydrolytic changes in protein solutions: the refractive index and hydration shells.

    PubMed

    Sarimov, R M; Matveyeva, T A; Binhi, V N

    2018-05-11

    Using an original laser interferometer of enhanced sensitivity, an increase in the refractive index of a protein solution was observed during the reaction of proteolysis catalyzed by pepsin. The increase in the refractive index of the protein solution at a concentration of 4 mg/ml was [Formula: see text] for bovine serum albumin and [Formula: see text] for lysozyme. The observed effect disproves the existing idea that the refractive index of protein solutions is determined only by their amino acid composition and concentration. It is shown that the refractive index also depends on the state of protein fragmentation. A mathematical model of proteolysis and a real-time method for estimating the state of protein hydration based on the measurement of refractive index during the reaction are proposed. A good agreement between the experimental and calculated time dependences of the refractive index shows that the growth of the surface of protein fragments and the change in the number of hydration cavities during proteolysis can be responsible for the observed effect.

  9. Temperature independent refractive index measurement using a fiber Bragg grating on abrupt tapered tip

    NASA Astrophysics Data System (ADS)

    Gomes, André D.; Silveira, Beatriz; Warren-Smith, Stephen C.; Becker, Martin; Rothhardt, Manfred; Frazão, Orlando

    2018-05-01

    A fiber Bragg grating was inscribed in an abrupt fiber taper using a femtosecond laser and phase-mask interferometer. The abrupt taper transition allows to excite a broad range of guided modes with different effective refractive indices that are reflected at different wavelengths according to Bragg's law. The multimode-Bragg reflection expands over 30 nm in the telecom-C-band. This corresponds to a mode-field overlap of up to 30% outside of the fiber, making the device suitable for evanescent field sensing. Refractive index and temperature measurements are performed for different reflection peaks. Temperature independent refractive index measurements are achieved by considering the difference between the wavelength shifts of two measured reflection peaks. A minimum refractive index sensitivity of 16 ± 1 nm/RIU was obtained in a low refractive index regime (1.3475-1.3720) with low influence of temperature (-0.32 ± 0.06 pm/°C). The cross sensitivity for this structure is 2.0 × 10-5 RIU/°C. The potential for simultaneous measurement of refractive index and temperature is also studied.

  10. Frequency of under-corrected refractive errors in elderly Chinese in Beijing.

    PubMed

    Xu, Liang; Li, Jianjun; Cui, Tongtong; Tong, Zhongbiao; Fan, Guizhi; Yang, Hua; Sun, Baochen; Zheng, Yuanyuan; Jonas, Jost B

    2006-07-01

    The aim of the study was to evaluate the prevalence of under-corrected refractive error among elderly Chinese in the Beijing area. The population-based, cross-sectional, cohort study comprised 4,439 subjects out of 5,324 subjects asked to participate (response rate 83.4%) with an age of 40+ years. It was divided into a rural part [1,973 (44.4%) subjects] and an urban part [2,466 (55.6%) subjects]. Habitual and best-corrected visual acuity was measured. Under-corrected refractive error was defined as an improvement in visual acuity of the better eye of at least two lines with best possible refractive correction. The rate of under-corrected refractive error was 19.4% (95% confidence interval, 18.2, 20.6). In a multiple regression analysis, prevalence and size of under-corrected refractive error in the better eye was significantly associated with lower level of education (P<0.001), female gender (P<0.001), and age (P=0.001). Under-correction of refractive error is relatively common among elderly Chinese in the Beijing area when compared with data from other populations.

  11. High-Efficiency Solar Thermal Vacuum Demonstration Completed for Refractive Secondary Concentrator

    NASA Technical Reports Server (NTRS)

    Wong, Wayne A.

    2001-01-01

    Common to many of the space applications that utilize solar thermal energy--such as electric power conversion, thermal propulsion, and furnaces--is a need for highly efficient, solar concentration systems. An effort is underway at the NASA Glenn Research Center to develop the refractive secondary concentrator, which uses refraction and total internal reflection to efficiently concentrate and direct solar energy. When used in combination with advanced lightweight primary concentrators, the refractive secondary concentrator enables very high system concentration ratios (10,000 to 1) and very high temperatures (>2000 K). The innovative refractive secondary concentrator offers significant advantages over all other types of secondary concentrators. The refractive secondary offers the highest throughput efficiency, provides for flux tailoring, requires no active cooling, relaxes the pointing and tracking requirements of the primary concentrator, and enables very high system concentration ratios. This technology has broad applicability to any system that requires the conversion of solar energy to heat. Glenn initiated the development of the refractive secondary concentrator in support of Shooting Star, a solar thermal propulsion flight experiment, and continued the development in support of Space Solar Power.

  12. Finite element approximation of the radiative transport equation in a medium with piece-wise constant refractive index

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lehtikangas, O., E-mail: Ossi.Lehtikangas@uef.fi; Tarvainen, T.; Department of Computer Science, University College London, Gower Street, London WC1E 6BT

    2015-02-01

    The radiative transport equation can be used as a light transport model in a medium with scattering particles, such as biological tissues. In the radiative transport equation, the refractive index is assumed to be constant within the medium. However, in biomedical media, changes in the refractive index can occur between different tissue types. In this work, light propagation in a medium with piece-wise constant refractive index is considered. Light propagation in each sub-domain with a constant refractive index is modeled using the radiative transport equation and the equations are coupled using boundary conditions describing Fresnel reflection and refraction phenomena onmore » the interfaces between the sub-domains. The resulting coupled system of radiative transport equations is numerically solved using a finite element method. The approach is tested with simulations. The results show that this coupled system describes light propagation accurately through comparison with the Monte Carlo method. It is also shown that neglecting the internal changes of the refractive index can lead to erroneous boundary measurements of scattered light.« less

  13. Investigative Studies of Refractive Indices of Liquids and a Demonstration of Refraction by the Use of a Laser Pointer and a Lazy Susan

    ERIC Educational Resources Information Center

    Wong, Siu Ling; Mak, Se-yuen

    2008-01-01

    We describe the design of a simple homemade apparatus for the measurement of the refractive indices of liquids and demonstration of refraction. A circular transparent plastic tank and a lazy Susan are held concentrically. A laser pointer is mounted on the lazy Susan with its laser beam pointing radially through the centre of the plastic tank.…

  14. A review of tropospheric refraction effects on Earth-to-satellite systems

    NASA Technical Reports Server (NTRS)

    Althsuler, E. E.

    1983-01-01

    Abnormal refractivity gradients may cause radio waves to be trapped within tropospheric layers, thus producing regions through which the waves do not pass called radio holes. For some locations and for many applications, refractive corrections based on the surface refractivity are adequate for elevation angles above a few degrees. However, new systems which operate at elevation angles near the horizon often require improved accuracies. Techniques for obtaining these improved corrections are reviewed.

  15. Holographic Optical Elements with Ultra-High Spatial Frequencies.

    DTIC Science & Technology

    1983-01-01

    optical film thickness is equal to one-quarter of the wavelength of the incident radiation and the film’s index of refraction is...Am amount of photoresist material removed by developer N diffractive order number n index of refraction nx index of refraction -- x direction ny index ...since a material with the required index of refraction is usually hard to find4 7 . For example, there is no inorganic material available for

  16. On the refractive index of sodium iodide solutions for index matching in PIV

    NASA Astrophysics Data System (ADS)

    Bai, Kunlun; Katz, Joseph

    2014-04-01

    Refractive index matching has become a popular technique for facilitating applications of modern optical diagnostic techniques, such as particle image velocimetry, in complex systems. By matching the refractive index of solid boundaries with that of the liquid, unobstructed optical paths can be achieved for illumination and image acquisition. In this research note, we extend previously provided data for the refractive index of aqueous solutions of sodium iodide (NaI) for concentrations reaching the temperature-dependent solubility limit. Results are fitted onto a quadratic empirical expression relating the concentration to the refractive index. Temperature effects are also measured. The present range of indices, 1.333-1.51, covers that of typical transparent solids, from silicone elastomers to several recently introduced materials that could be manufactured using rapid prototyping. We also review briefly previous measurements of the refractive index, viscosity, and density of NaI solutions, as well as prior research that has utilized this fluid.

  17. Comparison of remotely sensed continental-shelf wave spectra with spectra computed by using a wave refraction computer model

    NASA Technical Reports Server (NTRS)

    Poole, L. R.

    1976-01-01

    An initial attempt was made to verify the Langley Research Center and Virginia Institute of Marine Science mid-Atlantic continental-shelf wave refraction model. The model was used to simulate refraction occurring during a continental-shelf remote sensing experiment conducted on August 17, 1973. Simulated wave spectra compared favorably, in a qualitative sense, with the experimental spectra. However, it was observed that most of the wave energy resided at frequencies higher than those for which refraction and shoaling effects were predicted, In addition, variations among the experimental spectra were so small that they were not considered statistically significant. In order to verify the refraction model, simulation must be performed in conjunction with a set of significantly varying spectra in which a considerable portion of the total energy resides at frequencies for which refraction and shoaling effects are likely.

  18. Average value of the shape and direction factor in the equation of refractive index

    NASA Astrophysics Data System (ADS)

    Zhang, Tao

    2017-10-01

    The theoretical calculation of the refractive indices is of great significance for the developments of new optical materials. The calculation method of refractive index, which was deduced from the electron-cloud-conductor model, contains the shape and direction factor 〈g〉. 〈g〉 affects the electromagnetic-induction energy absorbed by the electron clouds, thereby influencing the refractive indices. It is not yet known how to calculate 〈g〉 value of non-spherical electron clouds. In this paper, 〈g〉 value is derived by imaginatively dividing the electron cloud into numerous little volume elements and then regrouping them. This paper proves that 〈g〉 = 2/3 when molecules’ spatial orientations distribute randomly. The calculations of the refractive indices of several substances validate this equation. This result will help to promote the application of the calculation method of refractive index.

  19. Effects of myopic spectacle correction and radial refractive gradient spectacles on peripheral refraction.

    PubMed

    Tabernero, Juan; Vazquez, Daniel; Seidemann, Anne; Uttenweiler, Dietmar; Schaeffel, Frank

    2009-08-01

    The recent observation that central refractive development might be controlled by the refractive errors in the periphery, also in primates, revived the interest in the peripheral optics of the eye. We optimized an eccentric photorefractor to measure the peripheral refractive error in the vertical pupil meridian over the horizontal visual field (from -45 degrees to 45 degrees ), with and without myopic spectacle correction. Furthermore, a newly designed radial refractive gradient lens (RRG lens) that induces increasing myopia in all radial directions from the center was tested. We found that for the geometry of our measurement setup conventional spectacles induced significant relative hyperopia in the periphery, although its magnitude varied greatly among different spectacle designs and subjects. In contrast, the newly designed RRG lens induced relative peripheral myopia. These results are of interest to analyze the effect that different optical corrections might have on the emmetropization process.

  20. Power-controlled transition from standard to negative refraction in reorientational soft matter.

    PubMed

    Piccardi, Armando; Alberucci, Alessandro; Kravets, Nina; Buchnev, Oleksandr; Assanto, Gaetano

    2014-11-25

    Refraction at a dielectric interface can take an anomalous character in anisotropic crystals, when light is negatively refracted with incident and refracted beams emerging on the same side of the interface normal. In soft matter subject to reorientation, such as nematic liquid crystals, the nonlinear interaction with light allows tuning of the optical properties. We demonstrate that in such material a beam of light can experience either positive or negative refraction depending on input power, as it can alter the spatial distribution of the optic axis and, in turn, the direction of the energy flow when traveling across an interface. Moreover, the nonlinear optical response yields beam self-focusing and spatial localization into a self-confined solitary wave through the formation of a graded-index waveguide, linking the refractive transition to power-driven readdressing of copolarized guided-wave signals, with a number of output ports not limited by diffraction.

  1. Retinal Image Simulation of Subjective Refraction Techniques

    PubMed Central

    Perches, Sara; Collados, M. Victoria; Ares, Jorge

    2016-01-01

    Refraction techniques make it possible to determine the most appropriate sphero-cylindrical lens prescription to achieve the best possible visual quality. Among these techniques, subjective refraction (i.e., patient’s response-guided refraction) is the most commonly used approach. In this context, this paper’s main goal is to present a simulation software that implements in a virtual manner various subjective-refraction techniques—including Jackson’s Cross-Cylinder test (JCC)—relying all on the observation of computer-generated retinal images. This software has also been used to evaluate visual quality when the JCC test is performed in multifocal-contact-lens wearers. The results reveal this software’s usefulness to simulate the retinal image quality that a particular visual compensation provides. Moreover, it can help to gain a deeper insight and to improve existing refraction techniques and it can be used for simulated training. PMID:26938648

  2. Database and new models based on a group contribution method to predict the refractive index of ionic liquids.

    PubMed

    Wang, Xinxin; Lu, Xingmei; Zhou, Qing; Zhao, Yongsheng; Li, Xiaoqian; Zhang, Suojiang

    2017-08-02

    Refractive index is one of the important physical properties, which is widely used in separation and purification. In this study, the refractive index data of ILs were collected to establish a comprehensive database, which included about 2138 pieces of data from 1996 to 2014. The Group Contribution-Artificial Neural Network (GC-ANN) model and Group Contribution (GC) method were employed to predict the refractive index of ILs at different temperatures from 283.15 K to 368.15 K. Average absolute relative deviations (AARD) of the GC-ANN model and the GC method were 0.179% and 0.628%, respectively. The results showed that a GC-ANN model provided an effective way to estimate the refractive index of ILs, whereas the GC method was simple and extensive. In summary, both of the models were accurate and efficient approaches for estimating refractive indices of ILs.

  3. Ultrasensitive Magnetic Field Sensing Based on Refractive-Index-Matched Coupling.

    PubMed

    Rao, Jie; Pu, Shengli; Yao, Tianjun; Su, Delong

    2017-07-07

    An ultrasensitive magnetic field sensor is proposed and investigated experimentally. The no-core fiber is fusion-spliced between two pieces of single-mode fibers and then immersed in magnetic fluid with an appropriate value of refractive index. Under the refractive-index-matched coupling condition, the guided mode becomes leaky and a coupling wavelength dip in the transmission spectrum of the structure is observed. The coupling wavelength dip is extremely sensitive to the ambient environment. The excellent sensitivity to the refractive index is measured to be 116.681 μm/RIU (refractive index unit) in the refractive index range of 1.45691-1.45926. For the as-fabricated sensors, the highest magnetic field sensing sensitivities of 6.33 and 1.83 nm/mT are achieved at low and high fields, respectively. The sensitivity is considerably enhanced compared with those of previously designed, similar structures.

  4. CHARMS: The Cryogenic, High-Accuracy Refraction Measuring System

    NASA Technical Reports Server (NTRS)

    Frey, Bradley; Leviton, Douglas

    2004-01-01

    The success of numerous upcoming NASA infrared (IR) missions will rely critically on accurate knowledge of the IR refractive indices of their constituent optical components at design operating temperatures. To satisfy the demand for such data, we have built a Cryogenic, High-Accuracy Refraction Measuring System (CHARMS), which, for typical 1R materials. can measure the index of refraction accurate to (+ or -) 5 x 10sup -3 . This versatile, one-of-a-kind facility can also measure refractive index over a wide range of wavelengths, from 0.105 um in the far-ultraviolet to 6 um in the IR, and over a wide range of temperatures, from 10 K to 100 degrees C, all with comparable accuracies. We first summarize the technical challenges we faced and engineering solutions we developed during the construction of CHARMS. Next we present our "first light," index of refraction data for fused silica and compare our data to previously published results.

  5. Determination of effective complex refractive index of a turbid liquid with surface plasmon resonance phase detection.

    PubMed

    Yingying, Zhang; Jiancheng, Lai; Cheng, Yin; Zhenhua, Li

    2009-03-01

    The dependence of the surface plasmon resonance (SPR) phase difference curve on the complex refractive index of a sample in Kretschmann configuration is discussed comprehensively, based on which a new method is proposed to measure the complex refractive index of turbid liquid. A corresponding experiment setup was constructed to measure the SPR phase difference curve, and the complex refractive index of turbid liquid was determined. By using the setup, the complex refractive indices of Intralipid solutions with concentrations of 5%, 10%, 15%, and 20% are obtained to be 1.3377+0.0005 i, 1.3427+0.0028 i, 1.3476+0.0034 i, and 1.3496+0.0038 i, respectively. Furthermore, the error analysis indicates that the root-mean-square errors of both the real and the imaginary parts of the measured complex refractive index are less than 5x10(-5).

  6. Visible to near-infrared refractive properties of freshly-excised human-liver tissues: marking hepatic malignancies

    PubMed Central

    Giannios, Panagiotis; Toutouzas, Konstantinos G.; Matiatou, Maria; Stasinos, Konstantinos; Konstadoulakis, Manousos M.; Zografos, George C.; Moutzouris, Konstantinos

    2016-01-01

    The refractive index is an optical constant that plays a significant role in the description of light-matter interactions. When it comes to biological media, refraction is understudied despite recent advances in the field of bio-optics. In the present article, we report on the measurement of the refractive properties of freshly excised healthy and cancerous human liver samples, by use of a prism-coupling technique covering the visible and near-infrared spectral range. Novel data on the wavelength-dependent complex refractive index of human liver tissues are presented. The magnitude of the real and imaginary part of the refractive index is correlated with hepatic pathology. Notably, the real index contrast is pointed out as a marker of discrimination between normal liver tissue and hepatic metastases. In view of the current progress in optical biosensor technologies, our findings may be exploited for the development of novel surgical and endoscopic tools. PMID:27297034

  7. Theoretical study of polarization insensitivity of carrier-induced refractive index change of multiple quantum well.

    PubMed

    Miao, Qingyuan; Zhou, Qunjie; Cui, Jun; He, Ping-An; Huang, Dexiu

    2014-12-29

    Characteristics of polarization insensitivity of carrier-induced refractive index change of 1.55 μm tensile-strained multiple quantum well (MQW) are theoretically investigated. A comprehensive MQW model is proposed to effectively extend the application range of previous models. The model considers the temperature variation as well as the nonuniform distribution of injected carrier in MQW. Tensile-strained MQW is expected to achieve polarization insensitivity of carrier-induced refractive index change over a wide wavelength range as temperature varies from 0°C to 40°C, while the magnitude of refractive index change keeps a large value (more than 3 × 10-3). And that the polarization insensitivity of refractive index change can maintain for a wide range of carrier concentration. Multiple quantum well with different material and structure parameters is anticipated to have the similar polarization insensitivity of refractive index change, which shows the design flexibility.

  8. The effects of partial and full correction of refractive errors on sensorial and motor outcomes in children with refractive accommodative esotropia.

    PubMed

    Sefi-Yurdakul, Nazife; Kaykısız, Hüseyin; Koç, Feray

    2018-03-17

    To investigate the effects of partial and full correction of refractive errors on sensorial and motor outcomes in children with refractive accommodative esotropia (RAE). The records of pediatric cases with full RAE were reviewed; their first and last sensorial and motor findings were evaluated in two groups, classified as partial (Group 1) and full correction (Group 2) of refractive errors. The mean age at first admission was 5.84 ± 3.62 years in Group 1 (n = 35) and 6.35 ± 3.26 years in Group 2 (n = 46) (p = 0.335). Mean change in best corrected visual acuity (BCVA) was 0.24 ± 0.17 logarithm of the minimum angle of resolution (logMAR) in Group 1 and 0.13 ± 0.16 logMAR in Group 2 (p = 0.001). Duration of deviation, baseline refraction and amount of reduced refraction showed significant effects on change in BCVA (p < 0.05). Significant correlation was determined between binocular vision (BOV), duration of deviation and uncorrected baseline amount of deviation (p < 0.05). The baseline BOV rates were significantly high in fully corrected Group 2, and also were found to have increased in Group 1 (p < 0.05). Change in refraction was - 0.09 ± 1.08 and + 0.35 ± 0.76 diopters in Groups 1 and 2, respectively (p = 0.005). Duration of deviation, baseline refraction and the amount of reduced refraction had significant effects on change in refraction (p < 0.05). Change in deviation without refractive correction was - 0.74 ± 7.22 prism diopters in Group 1 and - 3.24 ± 10.41 prism diopters in Group 2 (p = 0.472). Duration of follow-up and uncorrected baseline deviation showed significant effects on change in deviation (p < 0.05). Although the BOV rates and BCVA were initially high in fully corrected patients, they finally improved significantly in both the fully and partially corrected patients. Full hypermetropic correction may also cause an increase in the refractive error with a possible negative effect on emmetropization. The negative effect of the duration of deviation on BOV and BCVA demonstrates the significance of early treatment in RAE cases.

  9. Peripheral Refraction, Peripheral Eye Length, and Retinal Shape in Myopia.

    PubMed

    Verkicharla, Pavan K; Suheimat, Marwan; Schmid, Katrina L; Atchison, David A

    2016-09-01

    To investigate how peripheral refraction and peripheral eye length are related to retinal shape. Relative peripheral refraction (RPR) and relative peripheral eye length (RPEL) were determined in 36 young adults (M +0.75D to -5.25D) along horizontal and vertical visual field meridians out to ±35° and ±30°, respectively. Retinal shape was determined in terms of vertex radius of curvature Rv, asphericity Q, and equivalent radius of curvature REq using a partial coherence interferometry method involving peripheral eye lengths and model eye raytracing. Second-order polynomial fits were applied to RPR and RPEL as functions of visual field position. Linear regressions were determined for the fits' second order coefficients and for retinal shape estimates as functions of central spherical refraction. Linear regressions investigated relationships of RPR and RPEL with retinal shape estimates. Peripheral refraction, peripheral eye lengths, and retinal shapes were significantly affected by meridian and refraction. More positive (hyperopic) relative peripheral refraction, more negative RPELs, and steeper retinas were found along the horizontal than along the vertical meridian and in myopes than in emmetropes. RPR and RPEL, as represented by their second-order fit coefficients, correlated significantly with retinal shape represented by REq. Effects of meridian and refraction on RPR and RPEL patterns are consistent with effects on retinal shape. Patterns derived from one of these predict the others: more positive (hyperopic) RPR predicts more negative RPEL and steeper retinas, more negative RPEL predicts more positive relative peripheral refraction and steeper retinas, and steeper retinas derived from peripheral eye lengths predict more positive RPR.

  10. Effect of Pupil Size on Wavefront Refraction during Orthokeratology.

    PubMed

    Faria-Ribeiro, Miguel; Navarro, Rafael; González-Méijome, José Manuel

    2016-11-01

    It has been hypothesized that central and peripheral refraction, in eyes treated with myopic overnight orthokeratology, might vary with changes in pupil diameter. The aim of this work was to evaluate the axial and peripheral refraction and optical quality after orthokeratology, using ray tracing software for different pupil sizes. Zemax-EE was used to generate a series of 29 semi-customized model eyes based on the corneal topography changes from 29 patients who had undergone myopic orthokeratology. Wavefront refraction in the central 80 degrees of the visual field was calculated using three different quality metrics criteria: Paraxial curvature matching, minimum root mean square error (minRMS), and the Through Focus Visual Strehl of the Modulation Transfer Function (VSMTF), for 3- and 6-mm pupil diameters. The three metrics predicted significantly different values for foveal and peripheral refractions. Compared with the Paraxial criteria, the other two metrics predicted more myopic refractions on- and off-axis. Interestingly, the VSMTF predicts only a marginal myopic shift in the axial refraction as the pupil changes from 3 to 6 mm. For peripheral refraction, minRMS and VSMTF metric criteria predicted a higher exposure to peripheral defocus as the pupil increases from 3 to 6 mm. The results suggest that the supposed effect of myopic control produced by ortho-k treatments might be dependent on pupil size. Although the foveal refractive error does not seem to change appreciably with the increase in pupil diameter (VSMTF criteria), the high levels of positive spherical aberration will lead to a degradation of lower spatial frequencies, that is more significant under low illumination levels.

  11. The eye lens: age-related trends and individual variations in refractive index and shape parameters.

    PubMed

    Pierscionek, Barbara; Bahrami, Mehdi; Hoshino, Masato; Uesugi, Kentaro; Regini, Justyn; Yagi, Naoto

    2015-10-13

    The eye lens grows throughout life by cell accrual on its surface and can change shape to adjust the focussing power of the eye. Varying concentrations of proteins in successive cell layers create a refractive index gradient. The continued growth of the lens and age-related changes in proteins render it less able to alter shape with loss of capacity by the end of the sixth decade of life. Growth and protein ageing alter the refractive index but as accurate measurement of this parameter is difficult, the nature of such alterations remains uncertain. The most accurate method to date for measuring refractive index in intact lenses has been developed at the SPring-8 synchrotron. The technique, based on Talbot interferometry, has an X-ray source and was used to measure refractive index in sixty-six human lenses, aged from 16 to 91 years. Height and width were measured for forty-five lenses. Refractive index contours show decentration in some older lenses but individual variations mask age-related trends. Refractive index profiles along the optic axis have relatively flat central sections with distinct micro-fluctuations and a steep gradient in the cortex but do not exhibit an age-related trend. The refractive index profiles in the equatorial aspect show statistical significance with age, particularly for lenses below the age of sixty that had capacity to alter shape in vivo. The maximum refractive index in the lens centre decreases slightly with age with considerable scatter in the data and there are age-related variations in sagittal thickness and equatorial height.

  12. Prevalence of uncorrected refractive errors among school-age children in the School District of Philadelphia.

    PubMed

    Mayro, Eileen L; Hark, Lisa A; Shiuey, Eric; Pond, Michael; Siam, Linda; Hill-Bennett, Tamara; Tran, Judie; Khanna, Nitasha; Silverstein, Marlee; Donaghy, James; Zhan, Tingting; Murchison, Ann P; Levin, Alex V

    2018-06-01

    To determine the prevalence and severity of uncorrected refractive errors in school-age children attending Philadelphia public schools. The Wills Eye Vision Screening Program for Children is a community-based pediatric vision screening program designed to detect and correct refractive errors and refer those with nonrefractive eye diseases for examination by a pediatric ophthalmologist. Between January 2014 and June 2016 the program screened 18,974 children in grades K-5 in Philadelphia public schools. Children who failed the vision screening were further examined by an on-site ophthalmologist or optometrist; children whose decreased visual acuity was not amenable to spectacle correction were referred to a pediatric ophthalmologist. Of the 18,974 children screened, 2,492 (13.1%) exhibited uncorrected refractive errors: 1,776 (9.4%) children had myopia, 459 (2.4%) had hyperopia, 1,484 (7.8%) had astigmatism, and 846 (4.5%) had anisometropia. Of the 2,492 with uncorrected refractive error, 368 children (14.8%) had more than one refractive error diagnosis. In stratifying refractive error diagnoses by severity, mild myopia (spherical equivalent of -0.50 D to < -3.00 D) was the most common diagnosis, present in 1,573 (8.3%) children. In this urban population 13.1% of school-age children exhibited uncorrected refractive errors. Blurred vision may create challenges for students in the classroom; school-based vision screening programs can provide an avenue to identify and correct refractive errors. Copyright © 2018 American Association for Pediatric Ophthalmology and Strabismus. Published by Elsevier Inc. All rights reserved.

  13. Prevalence of refractive error in Europe: the European Eye Epidemiology (E(3)) Consortium.

    PubMed

    Williams, Katie M; Verhoeven, Virginie J M; Cumberland, Phillippa; Bertelsen, Geir; Wolfram, Christian; Buitendijk, Gabriëlle H S; Hofman, Albert; van Duijn, Cornelia M; Vingerling, Johannes R; Kuijpers, Robert W A M; Höhn, René; Mirshahi, Alireza; Khawaja, Anthony P; Luben, Robert N; Erke, Maja Gran; von Hanno, Therese; Mahroo, Omar; Hogg, Ruth; Gieger, Christian; Cougnard-Grégoire, Audrey; Anastasopoulos, Eleftherios; Bron, Alain; Dartigues, Jean-François; Korobelnik, Jean-François; Creuzot-Garcher, Catherine; Topouzis, Fotis; Delcourt, Cécile; Rahi, Jugnoo; Meitinger, Thomas; Fletcher, Astrid; Foster, Paul J; Pfeiffer, Norbert; Klaver, Caroline C W; Hammond, Christopher J

    2015-04-01

    To estimate the prevalence of refractive error in adults across Europe. Refractive data (mean spherical equivalent) collected between 1990 and 2013 from fifteen population-based cohort and cross-sectional studies of the European Eye Epidemiology (E(3)) Consortium were combined in a random effects meta-analysis stratified by 5-year age intervals and gender. Participants were excluded if they were identified as having had cataract surgery, retinal detachment, refractive surgery or other factors that might influence refraction. Estimates of refractive error prevalence were obtained including the following classifications: myopia ≤-0.75 diopters (D), high myopia ≤-6D, hyperopia ≥1D and astigmatism ≥1D. Meta-analysis of refractive error was performed for 61,946 individuals from fifteen studies with median age ranging from 44 to 81 and minimal ethnic variation (98 % European ancestry). The age-standardised prevalences (using the 2010 European Standard Population, limited to those ≥25 and <90 years old) were: myopia 30.6 % [95 % confidence interval (CI) 30.4-30.9], high myopia 2.7 % (95 % CI 2.69-2.73), hyperopia 25.2 % (95 % CI 25.0-25.4) and astigmatism 23.9 % (95 % CI 23.7-24.1). Age-specific estimates revealed a high prevalence of myopia in younger participants [47.2 % (CI 41.8-52.5) in 25-29 years-olds]. Refractive error affects just over a half of European adults. The greatest burden of refractive error is due to myopia, with high prevalence rates in young adults. Using the 2010 European population estimates, we estimate there are 227.2 million people with myopia across Europe.

  14. A survey of the prevalence of refractive errors among children in lower primary schools in Kampala district.

    PubMed

    Kawuma, Medi; Mayeku, Robert

    2002-08-01

    Refractive errors are a known cause of visual impairment and may cause blindness worldwide. In children, refractive errors may prevent those afflicted from progressing with their studies. In Uganda, like in many developing countries, there is no established vision-screening programme for children on commencement of school, such that those with early onset of such errors will have many years of poor vision. Over all, there is limited information on refractive errors among children in Africa. To determine the prevalence of refractive errors among school children attending lower primary in Kampala district; the frequency of the various types of refractive errors, and their relationship to sexuality and ethnicity. A cross-sectional descriptive study. Kampala district, Uganda A total of 623 children aged between 6 and 9 years had a visual acuity testing done at school using the same protocol; of these 301 (48.3%) were boys and 322 (51.7%) girls. Seventy-three children had a significant refractive error of +/-0.50 or worse in one or both eyes, giving a prevalence of 11.6% and the commonest single refractive error was astigmatism, which accounted for 52% of all errors. This was followed by hypermetropia, and myopia was the least common. Significant refractive errors occur among primary school children aged 6 to 9 years at a prevalence of approximately 12%. Therefore, there is a need to have regular and simple vision testing in primary school children at least at the commencement of school so as to defect those who may suffer from these disabilities.

  15. A Model of the Effect of Lens Development on Refraction in Schoolchildren.

    PubMed

    He, Ji C

    2017-12-01

    The study provides a new theory on the mechanism underlying myopia development, and it could be useful in clinical practice to control myopia development in schoolchildren. To model the effect of the crystalline lens on refractive development in schoolchildren. The Zemax 13 was used to calculate Zernike aberrations and refractions across 50° horizontal visual fields. Optical effects of the anterior chamber depth, lens thickness, and radii of curvature of the lens surfaces on refractions were modeled. Refractive changes induced by lens development in emmetropic and myopic eyes, based on a previous longitudinal study from literature, were calculated. A lens thickness reduction with an anterior chamber depth deepening caused a hyperopic shift over the visual fields and even more at the periphery. Opposite effects were found when the lens was thinned without any change of the anterior chamber depth. While a flattening of the anterior lens surface produced hyperopic refractions overall, a posterior lens flattening caused a myopic shift at the periphery, but a hyperopic shift of the central refraction. In the myopic eye, lens development induced refractive change toward more hyperopic over the visual fields and more at the periphery. Lens thinning and lens axial movement participate in peripheral refractive development in schoolchildren, and lens development with a deeper anterior chamber depth and a flatter lens surface in the myopic eye could generate extra hyperopia over visual fields. The myopic lens development could be due to a backward movement of the lens, driven by a backward growth of the ciliary process, which might be a causative factor of myopia development.

  16. Paediatric secondary intraocular lens estimation from the aphakic refraction alone: comparison with a standard biometric technique.

    PubMed

    Khan, A O; AlGaeed, A

    2006-12-01

    To compare the following two methods of paediatric secondary posterior chamber intraocular lens (PCIOL) determination with the Holladay formula: (1) estimation from the aphakic refraction alone (using assumed keratometry (K) of 44 diopters); and (2) calculation based on preoperative measured biometry. (1) Retrospective medical record review in a referral eye hospital of children with aphakia aged < or =12 years who underwent secondary PCIOL implantation with an Alcon MA60BM lens; (2) PCIOL determination for a plano refraction by the above two methods (estimation and calculation); and (3) prediction of pseudophakic refraction for the PCIOL actually implanted by the above two methods compared with the actual pseudophakic refraction. 50 eyes of 30 children with aphakia were studied. The estimated (mean, 95% confidence interval (CI)) secondary PCIOL values (25.81, +/-1.65 D) and the calculated secondary PCIOL values (26.35, +/-1.50 D) were not significantly different (mean absolute value of the difference 1.86 D, 95% CI +/-0.41 D) by the two-tailed paired t test at alpha = 0.05 (p = 0.11). For each eye, the pseudophakic refractions predicted by the two methods for the PCIOL that was actually implanted differed, both from each other and from the actual pseudophakic refraction (repeated-measures analysis of variance, p<0.001; Tukey test, p<0.01). The method of PCIOL estimation from the aphakic refraction alone provides values similar to those obtained by a standard technique and can be useful if biometry is unavailable. Targeting a pseudophakic refraction in paediatric aphakia is prone to error.

  17. The eye lens: age-related trends and individual variations in refractive index and shape parameters

    PubMed Central

    Pierscionek, Barbara; Bahrami, Mehdi; Hoshino, Masato; Uesugi, Kentaro; Regini, Justyn; Yagi, Naoto

    2015-01-01

    The eye lens grows throughout life by cell accrual on its surface and can change shape to adjust the focussing power of the eye. Varying concentrations of proteins in successive cell layers create a refractive index gradient. The continued growth of the lens and age-related changes in proteins render it less able to alter shape with loss of capacity by the end of the sixth decade of life. Growth and protein ageing alter the refractive index but as accurate measurement of this parameter is difficult, the nature of such alterations remains uncertain. The most accurate method to date for measuring refractive index in intact lenses has been developed at the SPring-8 synchrotron. The technique, based on Talbot interferometry, has an X-ray source and was used to measure refractive index in sixty-six human lenses, aged from 16 to 91 years. Height and width were measured for forty-five lenses. Refractive index contours show decentration in some older lenses but individual variations mask age-related trends. Refractive index profiles along the optic axis have relatively flat central sections with distinct micro-fluctuations and a steep gradient in the cortex but do not exhibit an age-related trend. The refractive index profiles in the equatorial aspect show statistical significance with age, particularly for lenses below the age of sixty that had capacity to alter shape in vivo. The maximum refractive index in the lens centre decreases slightly with age with considerable scatter in the data and there are age-related variations in sagittal thickness and equatorial height. PMID:26416418

  18. Automatic Refraction: How It Is Done: Some Clinical Results

    ERIC Educational Resources Information Center

    Safir, Aran; And Others

    1973-01-01

    Compaired are methods of determining visual refraction needs of young children or other unreliable observers by means of retinosocopy or the Opthalmetron, an automatic instrument which can be operated by a technician with no knowledge of refraction. (DB)

  19. Measuring the Index of Refraction.

    ERIC Educational Resources Information Center

    Phelps, F. M., III; Jacobson, B. S.

    1980-01-01

    Presents two methods for measuring the index of refraction of glass or lucite. These two methods, used in the freshman laboratory, are based on the fact that a ray of light inside a block will be refracted parallel to the surface. (HM)

  20. Refractive surgery in aircrew members who fly for scheduled and nonscheduled civilian airlines : final report.

    DOT National Transportation Integrated Search

    2000-05-01

    Introduction. Civil airmen with refractive surgery are present in all classes of aeromedical certificate holders. Refractive surgical procedures have been associated with numerous side effects, including glare, reduced contrast sensitivity, and fluct...

  1. Hard X-ray index of refraction tomography of a whole rabbit knee joint: A feasibility study.

    PubMed

    Gasilov, S; Mittone, A; Horng, A; Geith, T; Bravin, A; Baumbach, T; Coan, P

    2016-12-01

    We report results of the computed tomography reconstruction of the index of refraction in a whole rabbit knee joint examined at the photon energy of 51keV. Refraction based images make it possible to delineate the bone, cartilage, and soft tissues without adjusting the contrast window width and level. Density variations, which are related to tissue composition and are not visible in absorption X-ray images, are detected in the obtained refraction based images. We discuss why refraction-based images provide better detectability of low contrast features than absorption images. Copyright © 2016 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  2. Very low-refractive-index optical thin films consisting of an array of SiO2 nanorods

    NASA Astrophysics Data System (ADS)

    Xi, J.-Q.; Kim, Jong Kyu; Schubert, E. F.; Ye, Dexian; Lu, T.-M.; Lin, Shawn-Yu; Juneja, Jasbir S.

    2006-03-01

    The refractive-index contrast in dielectric multilayer structures, optical resonators, and photonic crystals is an important figure of merit that creates a strong demand for high-quality thin films with a low refractive index. A SiO2 nanorod layer with low refractive index of n=1.08, to our knowledge the lowest ever reported in thin-film materials, is grown by oblique-angle electron-beam deposition of SiO2. A single-pair distributed Bragg reflector employing a SiO2 nanorod layer is demonstrated to have enhanced reflectivity, showing the great potential of low-refractive-index films for applications in photonic structures and devices.

  3. Metamaterials with gradient negative index of refraction.

    PubMed

    Pinchuk, Anatoliy O; Schatz, George C

    2007-10-01

    We propose a new metamaterial with a gradient negative index of refraction, which can focus a collimated beam of light coming from a distant object. A slab of the negative refractive index metamaterial has a focal length that can be tuned by changing the gradient of the negative refractive index. A thin metal film pierced with holes of appropriate size or spacing between them can be used as a metamaterial with the gradient negative index of refraction. We use finite-difference time-domain calculations to show the focusing of a plane electromagnetic wave passing through a system of equidistantly spaced holes in a metal slab with decreasing diameters toward the edges of the slab.

  4. Equivalent refractive-index structure constant of non-Kolmogorov turbulence.

    PubMed

    Li, Yujie; Zhu, Wenyue; Wu, Xiaoqing; Rao, Ruizhong

    2015-09-07

    The relationship between the non-Kolmogorov refractive-index structure constant and the Kolmogorov refractive-index structure constant is derived by using the refractive-index structure function and the variance of refractive-index fluctuations. It shows that the non-Kolmogorov structure constant is proportional to the Kolmogorov structure constant and the scaling factor depends on the outer scale and the spectral power law. For a fixed Kolmogorov structure constant, the non-Kolmogorov structure constant increases with a increasing outer scale for the power law less than 11/3, the trend is opposite for the power law greater than 11/3. This equivalent relation provides a way of obtaining the non-Kolmogorov structure constant by using the Kolmogorov structure constant.

  5. On-chip integrated optofluidic complex refractive index sensing using silicon photonic crystal nanobeam cavities.

    PubMed

    Zhang, Xingwang; Zhou, Guangya; Shi, Peng; Du, Han; Lin, Tong; Teng, Jinghua; Chau, Fook Siong

    2016-03-15

    Complex refractive index sensing is proposed and experimentally demonstrated in optofluidic sensors based on silicon photonic crystal nanobeam cavities. The sensitivities are 58 and 139 nm/RIU, respectively, for the real part (n) and the imaginary part (κ) of the complex refractive index, and the corresponding detection limits are 1.8×10(-5) RIU for n and 4.1×10(-6) RIU for κ. Moreover, the capability of the complex refractive index sensing method to detect the concentration composition of the ternary mixture is demonstrated without the surface immobilization of functional groups, which is impossible to realize with the conventional refractive index sensing scheme.

  6. Photo-Induced Self-Condensation, A Technique For Fabricating Organic Lightguide Structures

    NASA Astrophysics Data System (ADS)

    Franke, H.; Heuer, W.

    1986-11-01

    Planar lightguides have been fabricated from mixtures of the polymer PMMA with benzoin type photoinitiators. Using conventional UV-photolithography 2 dimensional refractive index patterns were recorded in the polymer films. Thickness and refractive index of the organic lightguides were determined by m-line spectroscopy. The achieved refractive index changes increased with increasing photoinitiator concentrations. For high concentrations (< 70 %) the film refractive index could be increased via UV exposure by Δn = 0.03. Thermal treatment at below 100°C caused the out diffusion of the unexposed photoinitiator and completion of the photochemically induced reaction in the exposed parts of the film. Thus refractive index patterns (Δn < 0.05) could be developed and fixed.

  7. Refractive index sensing by Brillouin scattering in side-polished optical fibers.

    PubMed

    Bernini, Romeo; Persichetti, Gianluca; Catalano, Ester; Zeni, Luigi; Minardo, Aldo

    2018-05-15

    In this Letter, we demonstrate the possibility to measure the refractive index of a liquid, using the stimulating Brillouin scattering in a 3-cm-long side-polished optical fiber. In addition, we show that by depositing a high-refractive index layer on the polished surface the sensitivity of the Brillouin frequency shift (BFS) can be increased due to a higher penetration of the evanescent field in the outer medium. Experiments show a maximum BFS change of about 11 MHz when varying the refractive index of the external medium from 1 (air) to 1.402, and a BFS sensitivity to refractive index of about 293 MHz/RIU around 1.40.

  8. [Correction of light refraction and reflection in medical transmission optical tomography].

    PubMed

    Tereshchenko, S A; Potapov, D A

    2002-01-01

    The effects of light refraction and reflection on the quality of image reconstruction in medical transmission optical tomography of high-scattering media are considered. It has been first noted that light refraction not only distorts the geometric scheme of measurements, but may lead to the appearance of object areas that cannot be scanned. Some ways of decreasing the effect of refraction on the reconstruction of spatial distribution of the extinction coefficient are stated.

  9. Negative refraction in one- and two-dimensional lossless plasma dielectric photonic crystals

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Guo, B.

    2013-07-15

    Negative refraction in one- and two-dimensional lossless plasma dielectric photonic crystals consisting of plasma and background materials is theoretically investigated and the necessary conditions for negative refraction in these two structures are obtained. The critical frequency ω{sub 0} and the bandwidth Δω for negative refraction are explored, and the parameter dependence of effects such as plasma filling factor and the dielectric constant of background materials is also examined and discussed.

  10. Formation of bulk refractive index structures

    DOEpatents

    Potter, Jr., Barrett George; Potter, Kelly Simmons; Wheeler, David R.; Jamison, Gregory M.

    2003-07-15

    A method of making a stacked three-dimensional refractive index structure in photosensitive materials using photo-patterning where first determined is the wavelength at which a photosensitive material film exhibits a change in refractive index upon exposure to optical radiation, a portion of the surfaces of the photosensitive material film is optically irradiated, the film is marked to produce a registry mark. Multiple films are produced and aligned using the registry marks to form a stacked three-dimensional refractive index structure.

  11. Complex refractive index of starch acetate used as a biodegradable pigment and filler of paper

    NASA Astrophysics Data System (ADS)

    Karvinen, Petri; Oksman, Antti; Silvennoinen, Raimo; Mikkonen, Hannu

    2007-05-01

    Complex refractive index of strongly depolarizing starch acetate is investigated as a function of bulk package density, which is compulsory parameter in analysis of light scattering from nanoscale starch acetate pigments and fillers. The measurements were made using a laser-goniometer and spectrophotometer to gain data for refractive index analysis according to the Brewster's law and Fresnel equations. The real part of refractive index was verified by microscopic immersion method.

  12. Improved retroreflection method for measuring the refractive index of liquids.

    PubMed

    Shao, Duo; Tian, Linghao; Chen, Jingfei; Chen, Xianfeng

    2010-06-01

    We propose a new method for measuring the refractive index of liquids with high precision; the method is based on use of the optical fiber end face. As an example, we investigated the refractive index of sugar solution under varying conditions tens of times. The results show that this method has the advantage of higher stability and repeatability. The concentration and the temperature-dependent refractive index of the sugar solution is also experimentally studied.

  13. Method and apparatus for determining peak temperature along an optical fiber

    DOEpatents

    Fox, R.J.

    1982-07-29

    The invention relates to a new method and new apparatus for determining the hottest temperature or the coldest temperature prevailing along the length of an optical-fiber light guide. The invention is conducted with an optical fiber capable of supporting multidiode propagation of light and comprising a core, a cladding, and a jacket. The core is selected to have (1) a higher refractive index than the core and the cladding and (2) a relatively high negative temperature coefficient of refractive index. A light beam capable of establishing substantially single-mode propagation in the core is launched into an end thereof at an angle to the axis. The angle is increased to effect the onset of light fraction from the core into the cladding. The value of the launch angle corresponding to the onset is determined and then used to establish the refractive index of the core corresponding to the onset angle. The maximum temperature prevailing along the fiber then is determined from the (1) refractive index so determined and (2) the temperature coefficient of refractive index for the core. The invention is based on the finding that the launch angle corresponding to the onset of refraction into the cladding is uniquely determined by the maximum value of the ratio of the core refractive index to the cladding refractive index, which maximum occurs at the hottest point along the fiber.

  14. An evaluation of the accuracy of the ORange (Gen II) by comparing it to the IOLMaster in the prediction of postoperative refraction.

    PubMed

    Chen, Ming

    2012-01-01

    The aim of this study was to evaluate the accuracy of ORange(®) Gen II (WaveTec Vision, Aliso Viejo, CA). The Surgical Suites, Honolulu, HI. The prospective 28 consecutive cataract surgical cases were selected from 85 cataract surgical cases between December 16, 2010 and February 24, 2011. With the same intraocular lens implantation, the predicted spherical equivalent refraction from IOLMaster(®) (Carl Zeiss AG, Oberkochen, Germany) and ORange Gen II were statistically compared and verified with 1-month postoperative manifest refraction. The data were put into IBM SPSS 19 (SPSS Inc, Chicago, IL) for analysis of variance. Pearson's correlation coefficient was also calculated to evaluate the correlation between the IOLMaster, ORange Gen II, and 1-month postoperative manifest refraction. There were no statistically significant differences in the mean spherical equivalent refraction from the IOLMaster, ORange Gen II, and 1-month postoperative manifest refraction (IOLMaster -0.40 diopters, P = 0.07; ORange Gen II -0.43 diopters, P = 0.16; 1-month refraction -0.41 diopters, P = 0.07). Pearson's correlation study demonstrated that all three were positively correlated (P < 0.05), with the strongest correlation between the ORange Gen II and 1-month postoperative manifest refraction (r = +0.6, P < 0.01). The ORange Gen II can be considered as an alternative method for intraocular lens selection for cataract patients.

  15. Optical transillumination tomography with tolerance against refraction mismatch.

    PubMed

    Haidekker, Mark A

    2005-12-01

    Optical transillumination tomography (OT) is a laser-based imaging modality where ballistic photons are used for projection generation. Image reconstruction is therefore similar to X-ray computed tomography. This modality promises fast image acquisition, good resolution and contrast, and inexpensive instrumentation for imaging of weakly scattering objects, such as for example tissue-engineered constructs. In spite of its advantages, OT is not widely used. One reason is its sensitivity towards changes in material refractive index along the light path. Beam refraction artefacts cause areas of overestimated tissue density and blur geometric details. A spatial filter, introduced into the beam path to eliminate scattered photons, will also remove refracted photons from the projections. In the projections, zones affected by refraction can be detected by thresholding. By using algebraic reconstruction techniques (ART) in conjunction with suitable interpolation algorithms, reconstruction artefacts can be partly avoided. Reconstructions from a test image were performed. Standard filtered backprojection (FBP) showed a round mean square (RMS) deviation from the original image of 9.9. RMS deviation with refraction-tolerant ART reconstruction was 0.33 and 0.24, depending on the algorithm, compared to 0.57 (FBP) and 0.06 (ART) in a non-refracting case. In addition, modified ART reconstruction allowed detection of small geometric details that were invisible in standard reconstructions. Refraction-tolerant ART may be the key to eliminating one of the major challenges of OT.

  16. Comparisons of refractive errors between twins and singletons in Chinese school-age samples.

    PubMed

    Hur, Yoon-Mi; Zheng, Yingfeng; Huang, Wenyong; Ding, Xiaohu; He, Mingguang

    2009-02-01

    Studies have reported that refractive errors are associated with premature births. As twins have higher prevalence of prematurity than singletons, it is important to assess similarity of the prevalence of refractive errors in twins and singletons for proper interpretations and generalizations of the findings from twin studies. We compared refractive errors and diopter hours between 561 pairs of twins and 3757 singletons who are representative of school-age children (7-15 years) residing in an urban area of southern China. We found that the means and variances of the continuous measurement of spherical equivalent refractive error and diopter hours were not significantly different between twins and singletons. Although the prevalence of myopia was comparable between twins and singletons, that of hyperopia and astigmatism was slightly but significantly higher in twins than in singletons. These results are inconsistent with those of adult studies that showed no differences in refractive errors between twins and singletons. Given that the sample size of twins is relatively small and that this study is the first to demonstrate minor differences in refractive errors between twins and singletons, future replications are necessary to determine whether the slightly higher prevalence of refractive errors in twins than in singletons found in this study was due to a sampling error or to the developmental delay often observed in twins in childhood.

  17. Visual function of police officers who have undergone refractive surgery.

    PubMed

    Hovis, Jeffery K; Ramaswamy, Shankaran

    2006-11-01

    The visual acuity and contrast sensitivity of police recruits and officers was evaluated in both normal and dim illumination conditions to determine whether officers who have had refractive surgery have compromised night vision. The control group consisted of 76 officers and recruits who have not had refractive surgery and the refractive surgery group consisted of 22 officers and recruits who had refractive surgery. Visual acuity and contrast sensitivity were measured under both room illumination and dim illumination. The room illumination test series included high contrast acuity, low contrast acuity and Pelli-Robson contrast sensitivity. The dim illumination test series included high contrast acuity, low contrast acuity, Pelli-Robson contrast sensitivity, license plate number acuity (with and without glare) and the Mesotest. The general findings were that the refractive surgery group had lower acuity scores on low contrast targets in both room and dim light levels along with a reduction in the Mesotest scores with a glare source compared to the control group. Although refractive surgery police recruits and officers had reduced performance on some vision tests, these reductions were small and it is unlikely that their performance on vision related tasks would be compromised, on average. The major concern is the small number of refractive surgery candidates whose results were well outside the range of the non-surgical candidates. Their vision may be unacceptable for policing. Copyright (c) 2006 Wiley-Liss, Inc.

  18. Nonscanning Moiré deflectometry for measurement of nonlinear refractive index and absorption coefficient of liquids.

    PubMed

    Farahani, Shahrzad Shahrabi; Madanipour, Khosro; Koohian, Ata

    2017-05-01

    In this work, a nonscanning measurement technique is presented for determining the nonlinear refractive index and absorption coefficient of liquid media based on Moiré deflectometry. In the proposed method two lasers are used: a low power, wide beam as probe and a high power with specific wavelength as a pump. Interaction of the pump laser beam with the nonlinear sample changes the refractive index, which leads to change in convergence/divergence of the collimated incident probe laser beam. The induced deflection is monitored by Moiré deflectometry. If the pump laser has a Gaussian intensity profile, the refractive index profile of the sample is Gaussian, too. Measuring the deflection angle of the probe beam by Moiré fringes deflection, and by using the inverse Abel transform integral, the refractive index profile and nonlinear refractive index can be determined. This method is fast, easy, and insensitive to environmental noise and allows real-time measurement. Also, the refractive index profile of the interacted medium with pump laser can be achieved by this technique. As a liquid sample, a DCJ dye in water solution was studied. The value of nonlinear refractive index, n2, and absorption coefficient, α, were obtained -2.54×10-4  cm2 w-1 and 1.368  cm-1, respectively.

  19. Estimation of the refractive index of rigid contact lenses on the basis of back vertex power measurements.

    PubMed

    Pearson, Richard

    2011-03-01

    To assess the possibility of estimating the refractive index of rigid contact lenses on the basis of measurements of their back vertex power (BVP) in air and when immersed in liquid. First, a spreadsheet model was used to quantify the magnitude of errors arising from simulated inaccuracies in the variables required to calculate refractive index. Then, refractive index was calculated from in-air and in-liquid measurements of BVP of 21 lenses that had been made in three negative BVPs from materials with seven different nominal refractive index values. The power measurements were made by two operators on two occasions. Intraobserver reliability showed a mean difference of 0.0033±0.0061 (t = 0.544, P = 0.59), interobserver reliability showed a mean difference of 0.0043±0.0061 (t = 0.707, P = 0.48), and the mean difference between the nominal and calculated refractive index values was -0.0010±0.0111 (t = -0.093, P = 0.93). The spreadsheet prediction that low-powered lenses might be subject to greater errors in the calculated values of refractive index was substantiated by the experimental results. This method shows good intra and interobserver reliabilities and can be used easily in a clinical setting to provide an estimate of the refractive index of rigid contact lenses having a BVP of 3 D or more.

  20. Study on the effect of carbon nanotube coating on the refractive index sensing sensitivity of fiber modal interferometer

    NASA Astrophysics Data System (ADS)

    Zhang, Ya-nan; Xie, Wen-ge; Wang, Jianzhang; Wang, Pengzhao

    2018-01-01

    Refractive index sensing of liquid is important in the domain of chemistry and biology. Fiber optical sensors provide an excellent way to measure the refractive index due to their feasible integration to other fiber optics components, high sensitivity, small size, and distributed sensing. However, conventional optical sensors have different shortages. To find a practical way to measure the refractive index of liquid, this paper intended to combine Carbon Nanotube (CNT) with non-core fiber (NCF) to prepare a kind of modal interferometer sensor and to explore the effect of CNT coating on refractive index sensing properties of the modal interferometer. Firstly, a structure of single mode non-core single mode (SNS) fiber with a CNT film coating was proposed and simulated. The simulation results showed that the CNT coating could improve the refractive index sensitivity of the interferometer sensor. Then in the experiment part, the CNT solution was fabricated and deposited onto the NCF, and a refractive index sensing system was built to examine the property of the CNT-coated SNS interferometer sensor. During the experiment, the influence factors of sensitivity were summarized by testing the sensing performance under different conditions, and it was demonstrated that the CNT coating could improve the contrast of the interference spectrum, and also had the possibility to increase the refractive index sensitivity of the interferometer sensor.

  1. Agreement Between Autorefraction and Subjective Refraction in Keraring-Implanted Keratoconic Eyes.

    PubMed

    Al-Tuwairqi, Waleed S; Ogbuehi, Kelechi C; Razzouk, Haya; Alanazi, Mana A; Osuagwu, Uchechukwu L

    2017-03-01

    To assess the agreement between subjective refraction and autorefraction and to explore the relationship between the magnitude of higher order aberration, and visual acuity and refraction, before and after keraring implantation. This prospective, randomized, interventional study enrolled 27 subjects (mean age 28.1±6.5 years) with keratoconus. Noncycloplegic refraction was performed subjectively by one clinician and with an autorefractor by another clinician, before and 6 months after surgery. The limit of agreement (LoA) between methods was assessed, and the relationships between the corrected distance visual acuity, logMAR on the one hand and refraction measurements and higher-order aberrations on the other, were examined. The agreement in mean spherical equivalent refraction (MSER) between methods was good postoperatively but poor preoperatively. The autorefractor gave a more myopic refraction than subjective refraction preoperatively (-3.28±3.06 D; LoA -9.27 to +2.71 D, P<0.0001) and postoperatively (-0.63±1.64 D; LoA -3.85 to +2.58 D, P=0.055), and returned higher negative cylinders preoperatively (-1.10±1.17 D; LoA -3.40 to +1.19 D, P<0.0001) and postoperatively (-1.08±1.27 D; LoA -3.60 to +1.41 D, P<0.0001) in keratoconic eyes. The difference in MSER between methods was significantly related to the refractive error at both visits (P<0.05) and to the magnitude of higher-order aberrations in keratoconic eyes preoperatively (P<0.05). The logMAR visual acuity achieved subjectively worsened as the magnitude of higher-order aberrations increased preoperatively (P<0.001). The autorefractor returns values that are significantly more myopic in MSER and higher negative cylinders than subjective refraction, preoperatively, but the MSER was similar between devices postoperatively. The autorefactor seems a valid starting point for subjective refraction in keratoconic eyes treated with keraring, but the cylinder should be corrected by about +1 D. The instruments agree more in less myopic than high myopic eyes.

  2. Effect of atmospheric refraction on radiative transfer in visible and near-infrared band: Model development, validation, and applications

    NASA Astrophysics Data System (ADS)

    Hu, Shuai; Gao, Tai-chang; Li, Hao; Liu, Lei; Liu, Xi-chuan; Zhang, Ting; Cheng, Tian-ji; Li, Wan-tong; Dai, Zhong-hua; Su, Xiaojian

    2016-03-01

    Refraction is an important factor influencing radiative transfer since it can modify the propagation trajectory and polarization states of lights; therefore, it is necessary to quantitively evaluate the effect of atmospheric refraction on radiative transfer process. To this end, a new atmospheric radiative transfer model including refraction process is proposed. The model accuracy is validated against benchmark results, literature results, and well-tested radiative transfer models such as discrete coordinate method and RT3/PolRadtran. The impact of atmospheric refraction on both polarized radiance and fluxes is discussed for pure Rayleigh scattering atmosphere, atmosphere with aerosol, and cloud. The results show that atmospheric refraction has a significant influence on both the radiance and polarization states of diffuse light, where the relative change of the radiance of reflected light and transmitted light due to refraction can achieve 6.3% and 7.4% for Rayleigh scattering atmosphere, 7.2% and 7.8% for atmosphere with aerosol, and 6.2% and 6.8% for cloudy atmosphere, respectively. The relative change of the degree of polarization ranges from near zero in the horizon to 9.5% near neutral points. The angular distribution pattern of the relative change of the radiance for atmosphere with aerosol and cloud is very similar to that for pure Rayleigh scattering case, where its magnitude decreases gradually with the increasing of zenith angle for reflected light; but for transmitted light, the variation characteristics is opposite. The impact of refraction is gradually enhanced with the increasing of solar zenith angles and the optical depth of aerosol and cloud. As the wavelength of incident light increases, the impact declines rapidly for Rayleigh scattering medium. The relative change of the fluxes due to refraction is most notable for Middle Latitude Winter profile (about 8.2043% and 7.3225% for the transmitted and reflected light, respectively, at 0.35 µm). With increasing the optical depth of aerosol, the influence of refraction on the fluxes is gradually enhanced. For cloudy atmosphere, the relative changes of the fluxes due to refraction are not very sensitive to the variation of cloud optical depth and effective radius of cloud drops.

  3. Modeling of mouse eye and errors in ocular parameters affecting refractive state

    NASA Astrophysics Data System (ADS)

    Bawa, Gurinder

    Rodents eye are particularly used to study refractive error state of an eye and development of refractive eye. Genetic organization of rodents is similar to that of humans, which makes them interesting candidates to be researched upon. From rodents family mice models are encouraged over rats because of availability of genetically engineered models. Despite of extensive work that has been performed on mice and rat models, still no one is able to quantify an optical model, due to variability in the reported ocular parameters. In this Dissertation, we have extracted ocular parameters and generated schematics of eye from the raw data from School of Medicine, Detroit. In order to see how the rays would travel through an eye and the defects associated with an eye; ray tracing has been performed using ocular parameters. Finally we have systematically evaluated the contribution of various ocular parameters, such as radii of curvature of ocular surfaces, thicknesses of ocular components, and refractive indices of ocular refractive media, using variational analysis and a computational model of the rodent eye. Variational analysis revealed that variation in all the ocular parameters does affect the refractive status of the eye, but depending upon the magnitude of the impact those parameters are listed as critical or non critical. Variation in the depth of the vitreous chamber, thickness of the lens, radius of the anterior surface of the cornea, radius of the anterior surface of the lens, as well as refractive indices for the lens and vitreous, appears to have the largest impact on the refractive error and thus are categorized as critical ocular parameters. The radii of the posterior surfaces of the cornea and lens have much smaller contributions to the refractive state, while the radii of the anterior and posterior surfaces of the retina have no effect on the refractive error. These data provide the framework for further refinement of the optical models of the rat and mouse eye and suggest that extra efforts should be directed towards increasing the linear resolution of the rodent eye biometry and obtaining more accurate data for the refractive indices of the lens and vitreous.

  4. Retrieving the Vertical Structure of the Effective Aerosol Complex Index of Refraction from a Combination of Aerosol in Situ and Remote Sensing Measurements During TARFOX

    NASA Technical Reports Server (NTRS)

    Redemann, J.; Turco, R. P.; Liou, K. N.; Russell, P. B.; Bergstrom, R. W.; Schmid, B.; Livingston, J. M.; Hobbs, P. V.; Hartley, W. S.; Ismail, S.

    2000-01-01

    The largest uncertainty in estimates of the effects of atmospheric aerosols on climate stems from uncertainties in the determination of their microphysical properties, including the aerosol complex index of refraction, which in turn determines their optical properties. A novel technique is used to estimate the aerosol complex index of refraction in distinct vertical layers from a combination of aerosol in situ size distribution and remote sensing measurements during the Tropospheric Aerosol Radiative Forcing Observational Experiment (TARFOX). In particular, aerosol backscatter measurements using the NASA Langley LASE (Lidar Atmospheric Sensing Experiment) instrument and in situ aerosol size distribution data are utilized to derive vertical profiles of the 'effective' aerosol complex index of refraction at 815 nm (i.e., the refractive index that would provide the same backscatter signal in a forward calculation on the basis of the measured in situ particle size distributions for homogeneous, spherical aerosols). A sensitivity study shows that this method yields small errors in the retrieved aerosol refractive indices, provided the errors in the lidar derived aerosol backscatter are less than 30% and random in nature. Absolute errors in the estimated aerosol refractive indices are generally less than 0.04 for the real part and can be as much as 0.042 for the imaginary part in the case of a 30% error in the lidar-derived aerosol backscatter. The measurements of aerosol optical depth from the NASA Ames Airborne Tracking Sunphotometer (AATS-6) are successfully incorporated into the new technique and help constrain the retrieved aerosol refractive indices. An application of the technique to two TARFOX case studies yields the occurrence of vertical layers of distinct aerosol refractive indices. Values of the estimated complex aerosol refractive index range from 1.33 to 1.45 for the real part and 0.001 to 0.008 for the imaginary part. The methodology devised in this study provides, for the first time a complete set of vertically resolved aerosol size distribution and refractive index data, yielding the vertical distribution of aerosol optical properties required for the determination of aersol-induced radiative flux changes

  5. Retrieving the Vertical Structure of the Effective Aerosol Complex Index of Refraction from a Combination of Aerosol in Situ and Remote Sensing Measurements During TARFOX

    NASA Technical Reports Server (NTRS)

    Redemann, J.; Turco, R. P.; Liou, K. N.; Russell, P. B.; Bergstrom, R. W.; Schmid, B.; Livingston, J. M.; Hobbs, P. V.; Hartley, W. S.; Ismail, S.; hide

    2000-01-01

    The largest uncertainty in estimates of the effects of atmospheric aerosols on climate stems from uncertainties in the determination of their microphysical properties, including the aerosol complex index of refraction, which in turn determines their optical properties. A novel technique is used to estimate the aerosol complex index of refraction in distinct vertical layers from a combination of aerosol in situ size distribution and remote sensing measurements during the Tropospheric Aerosol Radiative Forcing Observational Experiment (TARFOX). In particular, aerosol backscatter measurements using the NASA Langley LASE (Lidar Atmospheric Sensing Experiment) instrument and in situ aerosol size distribution data are utilized to derive vertical profiles of the "effective" aerosol complex index of refraction at 815 nm (i.e., the refractive index that would provide the same backscatter signal in a forward calculation on the basis of the measured in situ particle size distributions for homogeneous, spherical aerosols). A sensitivity study shows that this method yields small errors in the retrieved aerosol refractive indices, provided the errors in the lidar-derived aerosol backscatter are less than 30% and random in nature. Absolute errors in the estimated aerosol refractive indices are generally less than 0.04 for the real part and can be as much as 0.042 for the imaginary part in the case of a 30% error in the lidar-derived aerosol backscatter. The measurements of aerosol optical depth from the NASA Ames Airborne Tracking Sunphotometer (AATS-6) are successfully incorporated into the new technique and help constrain the retrieved aerosol refractive indices. An application of the technique to two TARFOX case studies yields the occurrence of vertical layers of distinct aerosol refractive indices. Values of the estimated complex aerosol refractive index range from 1.33 to 1.45 for the real part and 0.001 to 0.008 for the imaginary part. The methodology devised in this study provides, for the first time, a complete set of vertically resolved aerosol size distribution and refractive index data. yielding the vertical distribution of aerosol optical properties required for the determination of aerosol-induced radiative flux changes.

  6. Pre- and Postcycloplegic Refractions in Children and Adolescents

    PubMed Central

    Zhu, Dan; Wang, Yan; Yang, Xianrong; Yang, Dayong; Guo, Kai; Guo, Yuanyuan; Jing, Xinxia; Pan, Chen-Wei

    2016-01-01

    Purpose To determine the difference between cycloplegic and non-cycloplegic refractive error and its associated factors in Chinese children and adolescents with a high prevalence of myopia. Methods A school-based study including 1565 students aged 6 to 21 years was conducted in 2013 in Ejina, Inner Mongolia, China. Comprehensive eye examinations were performed. Pre-and postcycloplegic refractive error were measured using an auto-refractor. For cycloplegic refraction, one drop of topical 1.0% cyclopentolate was administered to each eye twice with a 5-minute interval and a third drop was administered 15 minutes after the second drop if the pupil size was less than 6 mm or if the pupillary light reflex was still present. Results Two drops of cyclopentolate were found to be sufficient in 59% of the study participants while the other 41% need an additional drop. The prevalence of myopia was 89.5% in participants aged over 12 years and 68.6% in those aged 12 years or younger (P<0.001). When myopia was defined as spherical equivalent (SE) of less than -0.5 diopter (D), the prevalence estimates were 76.7% (95% confidence interval [CI] 74.6–78.8) and 54.1% (95%CI 51.6–56.6) before and after cycloplegic refraction, respectively. When hyperopia was defined as SE of more than 0.5D, the prevalence was only 2.8% (95%CI 1.9–3.6) before cycloplegic refraction while it was 15.5% (95%CI 13.7–17.3) after cycloplegic refraction. Increased difference between cycloplegic and non-cycloplegic refractive error was associated with decreased intraocular pressures (P = 0.01). Conclusions Lack of cycloplegia in refractive error measurement was associated with significant misclassifications in both myopia and hyperopia among Chinese children and adolescents. Decreased intraocular pressure was related to a greater difference between cycloplegic and non-cycloplegic refractive error. PMID:27907165

  7. Peripheral Refraction Validity of the Shin-Nippon SRW5000 Autorefractor.

    PubMed

    Osuagwu, Uchechukwu Levi; Suheimat, Marwan; Wolffsohn, James S; Atchison, David A

    2016-10-01

    To investigate the operation of the Shin-Nippon/Grand Seiko autorefractor and whether higher-order aberrations affect its peripheral refraction measurements. Information on instrument design, together with parameters and equations used to obtain refraction, was obtained from a patent. A model eye simulating the operating principles was tested with an optical design program. Effects of induced defocus and astigmatism on the retinal image were used to calibrate the model eye to match the patent equations. Coma and trefoil were added to assess their effects on the image. Peripheral refraction of a physical model eye was measured along four visual field meridians with the Shin-Nippon/Grand Seiko autorefractor SRW-5000 and a Hartmann-Shack aberrometer, and simulated autorefractor peripheral refraction was derived using the Zernike coefficients from the aberrometer. In simulation, the autorefractor's square image was changed in size by defocus, into rectangles or parallelograms by astigmatism, and into irregular shapes by coma and trefoil. In the presence of 1.0 D oblique astigmatism, errors in refraction were proportional to the higher-order aberrations, with up to 0.8 D sphere and 1.5 D cylinder for ±0.6 μm of coma or trefoil coefficients with a 5-mm-diameter pupil. For the physical model eye, refraction with the aberrometer was similar in all visual field meridians, but refraction with the autorefractor changed more quickly along one oblique meridian and less quickly along the other oblique meridian than along the horizontal and vertical meridians. Simulations predicted that higher-order aberrations would affect refraction in oblique meridians, and this was supported by the experimental measurements with the physical model eye. The autorefractor's peripheral refraction measurements are valid for horizontal and vertical field meridians, but not for oblique field meridians. Similar instruments must be validated before being adopted outside their design scope.

  8. Comparison of newer IOL power calculation methods for post-corneal refractive surgery eyes

    PubMed Central

    Wang, Li; Tang, Maolong; Huang, David; Weikert, Mitchell P.; Koch, Douglas D.

    2015-01-01

    Objective To compare the newer formulae, the optical coherence tomography based intraocular lens (IOL) power formula (OCT formula) and the Barrett True-K formula (True-K), to the methods on the ASCRS calculator in eyes with previous myopic LASIK/PRK. Design Prospective case series. Participants One-hundred and four eyes of 80 patients who had previous myopic LASIK/PRK and subsequent cataract surgery and IOL implantation. Methods Using the actual refraction following cataract surgery as target refraction, predicted IOL power for each method was calculated. The IOL prediction error (PE) was obtained by subtracting the predicted IOL power from the power of IOL implanted. Main outcome measures Arithmetic IOL PEs, variances of mean arithmetic IOL PE, median refractive PE and percent of eyes within 0.5 D and 1.0 D of refractive PE. Results OCT produced smaller variance of IOL PE than did Wang-Koch-Maloney, and Shammas (P<0.05). With the OCT, True-K No History, Wang-Koch-Maloney, Shammas, Haigis-L, and Average of these 5 formulas, respectively, the median refractive PEs were 0.35 D, 0.42 D, 0.51 D, 0.48 D, 0.39 D, and 0.35 D, and the % of eyes within 0.5 D of refractive PE were 68.3%, 58.7%, 50.0%, 52.9%, 55.8%, and 67.3%, and within 1.0 D of RPE, 92.3%, 90.4%, 86.9%, 88.5%, 90.4%, and 94.2%, respectively. The OCT formula had smaller refractive PE compared to Wang-Koch-Maloney and Shammas, and the Average approach produced significantly smaller refractive PE than did all methods except OCT (all P<0.05). Conclusions The OCT and True-K No History are promising formulas. The ASCRS IOL calculator has been updated to include the OCT and Barrett True K formulas. Trial registration Intraocular Lens Power Calculation After Laser Refractive Surgery Based on Optical Coherence Tomography (OCT IOL); Identifier: NCT00532051; www.ClinicalTrials.gov PMID:26459996

  9. Pre- and Postcycloplegic Refractions in Children and Adolescents.

    PubMed

    Zhu, Dan; Wang, Yan; Yang, Xianrong; Yang, Dayong; Guo, Kai; Guo, Yuanyuan; Jing, Xinxia; Pan, Chen-Wei

    2016-01-01

    To determine the difference between cycloplegic and non-cycloplegic refractive error and its associated factors in Chinese children and adolescents with a high prevalence of myopia. A school-based study including 1565 students aged 6 to 21 years was conducted in 2013 in Ejina, Inner Mongolia, China. Comprehensive eye examinations were performed. Pre-and postcycloplegic refractive error were measured using an auto-refractor. For cycloplegic refraction, one drop of topical 1.0% cyclopentolate was administered to each eye twice with a 5-minute interval and a third drop was administered 15 minutes after the second drop if the pupil size was less than 6 mm or if the pupillary light reflex was still present. Two drops of cyclopentolate were found to be sufficient in 59% of the study participants while the other 41% need an additional drop. The prevalence of myopia was 89.5% in participants aged over 12 years and 68.6% in those aged 12 years or younger (P<0.001). When myopia was defined as spherical equivalent (SE) of less than -0.5 diopter (D), the prevalence estimates were 76.7% (95% confidence interval [CI] 74.6-78.8) and 54.1% (95%CI 51.6-56.6) before and after cycloplegic refraction, respectively. When hyperopia was defined as SE of more than 0.5D, the prevalence was only 2.8% (95%CI 1.9-3.6) before cycloplegic refraction while it was 15.5% (95%CI 13.7-17.3) after cycloplegic refraction. Increased difference between cycloplegic and non-cycloplegic refractive error was associated with decreased intraocular pressures (P = 0.01). Lack of cycloplegia in refractive error measurement was associated with significant misclassifications in both myopia and hyperopia among Chinese children and adolescents. Decreased intraocular pressure was related to a greater difference between cycloplegic and non-cycloplegic refractive error.

  10. Predicting of the refractive index of haemoglobin using the Hybrid GA-SVR approach.

    PubMed

    Oyehan, Tajudeen A; Alade, Ibrahim O; Bagudu, Aliyu; Sulaiman, Kazeem O; Olatunji, Sunday O; Saleh, Tawfik A

    2018-04-30

    The optical properties of blood play crucial roles in medical diagnostics and treatment, and in the design of new medical devices. Haemoglobin is a vital constituent of the blood whose optical properties affect all of the optical properties of human blood. The refractive index of haemoglobin has been reported to strongly depend on its concentration which is a function of the physiology of biological cells. This makes the refractive index of haemoglobin an essential non-invasive bio-marker of diseases. Unfortunately, the complexity of blood tissue makes it challenging to experimentally measure the refractive index of haemoglobin. While a few studies have reported on the refractive index of haemoglobin, there is no solid consensus with the data obtained due to different measuring instruments and the conditions of the experiments. Moreover, obtaining the refractive index via an experimental approach is quite laborious. In this work, an accurate, fast and relatively convenient strategy to estimate the refractive index of haemoglobin is reported. Thus, the GA-SVR model is presented for the prediction of the refractive index of haemoglobin using wavelength, temperature, and the concentration of haemoglobin as descriptors. The model developed is characterised by an excellent accuracy and very low error estimates. The correlation coefficients obtained in these studies are 99.94% and 99.91% for the training and testing results, respectively. In addition, the result shows an almost perfect match with the experimental data and also demonstrates significant improvement over a recent mathematical model available in the literature. The GA-SVR model predictions also give insights into the influence of concentration, wavelength, and temperature on the RI measurement values. The model outcome can be used not only to accurately estimate the refractive index of haemoglobin but also could provide a reliable common ground to benchmark the experimental refractive index results. Copyright © 2018 Elsevier Ltd. All rights reserved.

  11. Refractive Errors in 3–6 Year-Old Chinese Children: A Very Low Prevalence of Myopia?

    PubMed Central

    Lin, Lixia; Li, Zhen; Zeng, Junwen; Yang, Zhikuan; Morgan, Ian G.

    2013-01-01

    Purpose To examine the prevalence of refractive errors in children aged 3–6 years in China. Methods Children were recruited for a trial of a home-based amblyopia screening kit in Guangzhou preschools, during which cycloplegic refractions were measured in both eyes of 2480 children. Cycloplegic refraction (from 3 to 4 drops of 1% cyclopentolate to ensure abolition of the light reflex) was measured by both autorefraction and retinoscopy. Refractive errors were defined as followed: myopia (at least −0.50 D in the worse eye), hyperopia (at least +2.00 D in the worse eye) and astigmatism (at least 1.50 D in the worse eye). Different definitions, as specified in the text, were also used to facilitate comparison with other studies. Results The mean spherical equivalent refractive error was at least +1.22 D for all ages and both genders. The prevalence of myopia for any definition at any age was at most 2.5%, and lower in most cases. In contrast, the prevalence of hyperopia was generally over 20%, and declined slightly with age. The prevalence of astigmatism was between 6% and 11%. There was very little change in refractive error with age over this age range. Conclusions Previous reports of less hyperopic mean spherical equivalent refractive error, and more myopia and less hyperopia in children of this age may be due to problems with achieving adequate cycloplegia in children with dark irises. Using up to 4 drops of 1% cyclopentolate may be necessary to accurately measure refractive error in paediatric studies of such children. Our results suggest that children from all ethnic groups may follow a similar pattern of early refractive development, with little myopia and a hyperopic mean spherical equivalent over +1.00 D up to the age of 5–6 yearsin most conditions. PMID:24205064

  12. Profile of refractive errors in European Caucasian children with Autistic Spectrum Disorder; increased prevalence and magnitude of astigmatism.

    PubMed

    Anketell, Pamela M; Saunders, Kathryn J; Gallagher, Stephen; Bailey, Clare; Little, Julie-Anne

    2016-07-01

    Autistic Spectrum Disorder (ASD) is a common neurodevelopmental disorder characterised by impairment of communication, social interaction and repetitive behaviours. Only a small number of studies have investigated fundamental clinical measures of vision including refractive error. The aim of this study was to describe the refractive profile of a population of children with ASD compared to typically developing (TD) children. Refractive error was assessed using the Shin-Nippon NVision-K 5001 open-field autorefractor following the instillation of cyclopentolate hydrochloride 1% eye drops. A total of 128 participants with ASD (mean age 10.9 ± 3.3 years) and 206 typically developing participants (11.5 ± 3.1 years) were recruited. There was no significant difference in median refractive error, either by spherical equivalent or most ametropic meridian between the ASD and TD groups (Spherical equivalent, Mann-Whitney U307 = 1.15, p = 0.25; Most Ametropic Meridian, U305 = 0.52, p = 0.60). Median refractive astigmatism was -0.50DC (range 0.00 to -3.50DC) for the ASD group and -0.50DC (Range 0.00 to -2.25DC) for the TD group. Magnitude and prevalence of refractive astigmatism (defined as astigmatism ≥1.00DC) was significantly greater in the ASD group compared to the typically developing group (ASD 26%, TD 8%, magnitude U305 = 3.86, p = 0.0001; prevalence (χ12=17.71 , p < 0.0001). This is the first study to describe the refractive profile of a population of European Caucasian children with ASD compared to a TD population of children. Unlike other neurodevelopmental conditions, there was no increased prevalence of spherical refractive errors in ASD but astigmatic errors were significantly greater in magnitude and prevalence. This highlights the need to examine refractive errors in this population. © 2016 The Authors Ophthalmic & Physiological Optics © 2016 The College of Optometrists.

  13. Study on the refractive errors of school going children of Pokhara city in Nepal.

    PubMed

    Niroula, D R; Saha, C G

    Refractive errors are the one of the most common visual disorders found worldwide in school going children and also it is one of the causes of blindness. It can easily be prevented, if timely proper measures are taken. In Kathmandu valley and Mechi Zone of Nepal, the distribution of refractive errors was found to be very high. No records are available from the Western part of Nepal. Considering the importance of the refractive errors the present study had been undertaken in Pokhara city. 964 subjects (474 boys, 490 girls) were selected between age groups 10 to 19 years from 6 schools representing different region of Pokhara. After Preliminary examination: on acuity of vision with Snellen's and Jaeger's charts, the subjects were referred to the Manipal Teaching Hospital, Pokhara for confirmation of the refractive errors. Sixty two schools children (6.43%), out of 964 had refractive errors. The myopia was found to be most common (4.05%). The refractive errors were found more in Private school children (9.29%) than Government school children (4.23%), which is statistically significant (P < 0.05). More boys (7.59%) were found to have suffered from refractive errors than girls (5.31%). Further, children with vegetarian diet (10.52%) had greater number of refractive errors than non-vegetarian diet children (6.17%). In the present study, percentage distribution of myopia was found to be higher (4.05%) than the hyperopia (1.24%) and astigmatism (1.14%). Interestingly, in the present study the refractive errors were found significantly higher in Private schools children than Government schools because the children who read in Private schools have higher socioeconomic status; spend more time in home work, watching Television and Computer as compared to government schools children. These near activities of the eyes causes stress on eyes of the children and might be one of the causes of developing myopia.

  14. Retrospective analysis of refractive errors in children with vision impairment.

    PubMed

    Du, Jojo W; Schmid, Katrina L; Bevan, Jennifer D; Frater, Karen M; Ollett, Rhondelle; Hein, Bronwyn

    2005-09-01

    Emmetropization is the reduction in neonatal refractive errors that occurs after birth. Ocular disease may affect this process. We aimed to determine the relative frequency of ocular conditions causing vision impairment in the pediatric population and characterize the refractive anomalies present. We also compared the causes of vision impairment in children today to those between 1974 and 1981. Causes of vision impairment and refractive data of 872 children attending a pediatric low-vision clinic from 1985 to 2002 were retrospectively collated. As a result of associated impairments, refractive data were not available for 59 children. An analysis was made of the causes of vision impairment, the distribution of refractive errors in children with vision impairment, and the average type of refractive error for the most commonly seen conditions. We found that cortical or cerebral vision impairment (CVI) was the most common condition causing vision impairment, accounting for 27.6% of cases. This was followed by albinism (10.6%), retinopathy of prematurity (ROP; 7.0%), optic atrophy (6.2%), and optic nerve hypoplasia (5.3%). Vision impairment was associated with ametropia; fewer than 25% of the children had refractive errors < or = +/-1 D. The refractive error frequency plots (for 0 to 2-, 6 to 8-, and 12 to 14-year age bands) had a Gaussian distribution indicating that the emmetropization process was abnormal. The mean spherical equivalent refractive error of the children (n = 813) was +0.78 +/- 6.00 D with 0.94 +/- 1.24 D of astigmatism and 0.92 +/- 2.15 D of anisometropia. Most conditions causing vision impairment such as albinism were associated with low amounts of hyperopia. Moderate myopia was observed in children with ROP. The relative frequency of ocular conditions causing vision impairment in children has changed since the 1970s. Children with vision impairment often have an associated ametropia suggesting that the emmetropization system is also impaired.

  15. Studies of intrastromal corneal ring segments for the correction of low to moderate myopic refractive errors.

    PubMed Central

    Schanzlin, D J

    1999-01-01

    PURPOSE: Intrastromal corneal ring segments (ICRS) were investigated for safety and reliability in the correction of low to moderate myopic refractive errors. METHODS: Initially, 74 patients with spherical equivalent refractive errors between -1.00 and -4.25 diopters (D) received the ICRS in 1 eye. After 6 months, 51 of these patients received the ICRS in the contralateral eye. The total number of eyes investigated was 125. The outcome measures were uncorrected and best-corrected visual acuity, predictability and stability of the refraction, refractive astigmatism, contrast sensitivity, and endothelial cell morphology. RESULTS: The 89 eyes with 12-month follow-up showed significant improvement with uncorrected visual acuities of 20/16 or better in 37%, 20/20 or better in 62%, and 20/40 or better in 97%. Cycloplegic refraction spherical equivalents showed that 68% of the eyes were within +/- 0.50 D and 90% within +/- 1.00 D of the intended correction. Refractive stability was present by 3 months after the surgery. Only 1 patients had a loss greater than 2 lines or 10 letters of best spectacle-corrected visual acuity, but the patient's acuity was 20/20. Refractive cylinder, contrast sensitivity, and endothelial cell morphology were not adversely affected. The ICRS was removed from the eyes of 6 patients. Three removals were prompted by glare and double images occurring at night; 3 were for nonmedical reasons. All patients returned to within +/- 1.00 D of their preoperative refractive spherical equivalent, and no patients lost more than 1 line of best corrected visual acuity by 3 months after ICRS removal. CONCLUSION: The ICRS safely and reliably corrects myopic refractive errors between -1.00 and -4.50 D. Images FIGURE 1 FIGURE 2 FIGURE 3 FIGURE 6 FIGURE 7 FIGURE 8 FIGURE 9 FIGURE 10 FIGURE 11 FIGURE 12 PMID:10703146

  16. Accommodation and the Visual Regulation of Refractive State in Marmosets

    PubMed Central

    Troilo, David; Totonelly, Kristen; Harb, Elise

    2009-01-01

    Purpose To determine the effects of imposed anisometropic retinal defocus on accommodation, ocular growth, and refractive state changes in marmosets. Methods Marmosets were raised with extended-wear soft contact lenses for an average duration of 10 wks beginning at an average age of 76 d. Experimental animals wore either a positive or negative contact lens over one eye and a plano lens or no lens over the other. Another group wore binocular lenses of equal magnitude but opposite sign. Untreated marmosets served as controls and three wore plano lenses monocularly. Cycloplegic refractive state, corneal curvature, and vitreous chamber depth were measured before, during, and after the period of lens wear. To investigate the accommodative response, the effective refractive state was measured through each anisometropic condition at varying accommodative stimuli positions using an infrared refractometer. Results Eye growth and refractive state are significantly correlated with the sign and power of the contact lens worn. The eyes of marmosets reared with monocular negative power lenses had longer vitreous chambers and were myopic relative to contralateral control eyes (p<0.01). Monocular positive power lenses produced a significant reduction in vitreous chamber depth and hyperopia relative to the contralateral control eyes (p<0.05). In marmosets reared binocularly with lenses of opposite sign, we found larger interocular differences in vitreous chamber depths and refractive state (p<0.001). Accommodation influences the defocus experienced through the lenses, however, the mean effective refractive state was still hyperopia in the negative-lens-treated eyes and myopia in the positive-lens-treated eyes. Conclusions Imposed anisometropia effectively alters marmoset eye growth and refractive state to compensate for the imposed defocus. The response to imposed hyperopia is larger and faster than the response to imposed myopia. The pattern of accommodation under imposed anisometropia produces effective refractive states that are consistent with the changes in eye growth and refractive state observed. PMID:19104464

  17. LASIK for spherical refractive myopia: effect of topographic astigmatism (ocular residual astigmatism, ORA) on refractive outcome.

    PubMed

    Frings, Andreas; Richard, Gisbert; Steinberg, Johannes; Skevas, Christos; Druchkiv, Vasyl; Katz, Toam; Linke, Stephan J

    2015-01-01

    In eyes with a preoperative plano refractive cylinder, it would appear that there is no rationale for astigmatic treatment. The aim of this retrospective, cross-sectional data analysis was to determine the amount of topographic astigmatism in refractive plano eyes that results in reduced efficacy after myopic laser in situ keratomileusis (LASIK). This study included 267 eyes from 267 consecutive myopic patients with a refractive plano cylinder. Receiver operating characteristic analysis was used to find the cut-off values of preoperative ocular residual astigmatism (= topographic astigmatism) that can best discriminate between groups of efficacy and safety indices in preoperative plano refractive cylinder eyes. Preoperative ocular residual astigmatism (ORA) (or topographic astigmatism) of ≤0.9 diopters (D) resulted in an efficacy index of at least 0.8 statistically significantly more frequently than eyes with a preoperative ORA of >0.9 D. Eyes with a high ORA preoperatively also had a high ORA postoperatively. Regression analysis showed that each diopter of preoperative ORA reduced efficacy by 0.07. A preoperative corneal astigmatism of ≥0.9 D could (partially) be taken into account in the LASIK design, even if the subjective refractive astigmatism is neutral.

  18. Corneal refractive surgery: Is intracorneal the way to go and what are the needs for technology?

    NASA Astrophysics Data System (ADS)

    Hjortdal, Jesper; Ivarsen, Anders

    2014-02-01

    Corneal refractive surgery aims to reduce or eliminate refractive errors of the eye by changing the refractive power of the cornea. For the last 20 years controlled excimer laser ablation of corneal tissue, either directly from the corneal stromal surface or from the corneal interior after creation of a superficial corneal flap has become widely used to correct myopia, hyperopia, and astigmatism. Recently, an intrastromal refractive procedure whereby a tissue lenticule is cut free in the corneal stroma by a femtosecond laser and removed through a small peripheral incision has been introduced. This procedure avoids creation of a corneal flap and the potential associated risks while avoiding the slow visual recovery of surface ablation procedures. Precise intrastromal femtosecond laser cutting of the fine lenticule requires very controlled laser energy delivery in order to avoid lenticule irregularities, which would compromise the refractive result and visual acuity. This newly introduced all-femtosecond based flap-free intracorneal refractive procedure has been documented to be a predictable, efficient, and safe procedure for correction of myopia and astigmatism. Technological developments related to further improved cutting quality, hyperopic and individualized treatments are desirable.

  19. Effect of TiCl4 treatment on the refractive index of nanoporous TiO2 films

    NASA Astrophysics Data System (ADS)

    Lee, Jeeyoung; Lee, Myeongkyu

    2015-12-01

    We investigate the effect of TiCl4 treatment on the refractive index of a nanoporous TiO2 film. A nanoparticulate TiO2 film prepared on a glass substrate was immersed in a TiCl4 aqueous solution. The subsequent reaction of TiCl4 with H2O produces TiO2 and thus modifies the density and the refractive index of the film. With increasing TiCl4 concentration, the refractive index initially increased and then declined after being maximized (n = 2.02 at 633 nm) at 0.08 M concentration. A refractive index change as large as 0.45 could be obtained with the TiCl4 treatment, making it possible to achieve diffraction efficiency exceeding 80% in a diffraction grating-embedded TiO2 film. For high TiCl4 concentrations of 0.32 M and 0.64 M, the refractive index remained nearly unchanged. This was attributed to the limited permeability of high-viscosity TiCl4 solutions into the nanoporous films. The measured pore size distributions were in good agreement with the results of a diffraction analysis and refractive index measurement.

  20. Management of irregular astigmatism.

    PubMed

    Goggin, M; Alpins, N; Schmid, L M

    2000-08-01

    Using a liberal definition of corneal irregularity, modern videokeratoscopy may define approximately 40% of normal corneas with a toric refractive error as possessing primary irregular astigmatism. The causes of secondary forms of irregular astigmatism include corneal surgery, trauma, dystrophies, and infections. Internal refractive surface and media irregularity or noncorneal astigmatism (ocular residual astigmatism) contribute to irregular astigmatism of the entire refractive path of which crystaline lenticular astigmatism is usually the principal contributing component. Treatment options have increased in recent years, particularly, though not exclusively, through the advent of tailored corneal excimer laser ablations. However, discussion continues concerning the systematic approach necessary to enable treatment to achieve an optimal optical surface for the eye. Discussion also continues as to what constitutes the optimal corneal shape. Some refractive procedures may increase higher order aberrations in the attempt to neutralize refractive astigmatism. The way to further refinement of the commonly performed refractive techniques will ultimately lie in the integrated inclusion of a trio of technologies: topographic analysis of the corneal surface, wavefront analysis of ocular refractive aberrations, and vector planning to enable the appropriate balance in emphasis between these two diagnostic modalities. For the uncommon, irregularly roughened corneas, the ablatable polymer techniques show some promise.

  1. Seismic refraction survey of the ANS preferred site

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Davis, R.K.; Hopkins, R.A.; Doll, W.E.

    1992-02-01

    Between September 19, 1991 and October 8, 1991 personnel from Martin Marietta Energy Systems, Inc. (Energy Systems), Automated Sciences Group, Inc., and Marrich, Inc. performed a seismic refraction survey at the Advanced Neutron Source (ANS) preferred site. The purpose of this survey was to provide estimates of top-of-rock topography, based on seismic velocities, and to delineate variations in rock and soil velocities. Forty-four seismic refraction spreads were shot to determine top-of-rock depths at 42 locations. Nine of the seismic spreads were shot with long offsets to provide 216 top-of-rock depths for 4 seismic refraction profiles. The refraction spread locations weremore » based on the grid for the ANS Phase I drilling program. Interpretation of the seismic refraction data supports the assumption that the top-of-rock surface generally follows the local topography. The shallow top-of-rock interface interpreted from the seismic refraction data is also supported by limited drill information at the site. Some zones of anomalous data are present that could be the result of locally variable weathering, a localized variation in shale content, or depth to top-of-rock greater than the site norm.« less

  2. A Newtonian approach to extraordinarily strong negative refraction.

    PubMed

    Yoon, Hosang; Yeung, Kitty Y M; Umansky, Vladimir; Ham, Donhee

    2012-08-02

    Metamaterials with negative refractive indices can manipulate electromagnetic waves in unusual ways, and can be used to achieve, for example, sub-diffraction-limit focusing, the bending of light in the 'wrong' direction, and reversed Doppler and Cerenkov effects. These counterintuitive and technologically useful behaviours have spurred considerable efforts to synthesize a broad array of negative-index metamaterials with engineered electric, magnetic or optical properties. Here we demonstrate another route to negative refraction by exploiting the inertia of electrons in semiconductor two-dimensional electron gases, collectively accelerated by electromagnetic waves according to Newton's second law of motion, where this acceleration effect manifests as kinetic inductance. Using kinetic inductance to attain negative refraction was theoretically proposed for three-dimensional metallic nanoparticles and seen experimentally with surface plasmons on the surface of a three-dimensional metal. The two-dimensional electron gas that we use at cryogenic temperatures has a larger kinetic inductance than three-dimensional metals, leading to extraordinarily strong negative refraction at gigahertz frequencies, with an index as large as -700. This pronounced negative refractive index and the corresponding reduction in the effective wavelength opens a path to miniaturization in the science and technology of negative refraction.

  3. Iodine insertion and dispersion of refractive index in organic single crystal semiconductor.

    PubMed

    Kwon, Seonho; Bae, Junwan; Lee, I J

    2018-02-20

    Insertion of halogens such as bromine or iodine affects the electronic polarizability of ions and the local field inside the medium, and thus modifies the refractive index. Acquiring precise knowledge of the dispersion of refractive index and ultimately tailoring conventional semiconductors for wide-range refractive index control have been a vital issue to resolve before realizing advanced organic optoelectronic devices. In this report, dispersions of the refractive index of a single crystal tetramethyltetraselenafulvalene [C 10 H 12 Se 4 ] (TMTSF) are thoroughly studied from broadband interference modulations of photoluminescence (PL) spectra at various temperatures and doping levels. A large enhancement of the refractive index, more than 20% of the intrinsic value, is achieved with inclusion of a small composition of iodide ions, while the structural and optical properties remain mostly intact. Nearly temperature independent dispersion of the refractive index suggests that, unlike most polymers in which the thermal expansion coefficient dominates over the change of polarizability with temperature, the latter enhances significantly and may become more or less comparable to the thermal expansion coefficient given by 1.71 × 10 -4 /K, when single crystal TMTSF is doped by iodine.

  4. Recovering fluorophore concentration profiles from confocal images near lateral refractive index step changes.

    PubMed

    Jonášová, Eleonóra Parelius; Bjørkøy, Astrid; Stokke, Bjørn Torger

    2016-12-01

    Optical aberrations due to refractive index mismatches occur in various types of microscopy due to refractive differences between the sample and the immersion fluid or within the sample. We study the effects of lateral refractive index differences by fluorescence confocal laser scanning microscopy due to glass or polydimethylsiloxane cuboids and glass cylinders immersed in aqueous fluorescent solution, thereby mimicking realistic imaging situations in the proximity of these materials. The reduction in fluorescence intensity near the embedded objects was found to depend on the geometry and the refractive index difference between the object and the surrounding solution. The observed fluorescence intensity gradients do not reflect the fluorophore concentration in the solution. It is suggested to apply a Gaussian fit or smoothing to the observed fluorescence intensity gradient and use this as a basis to recover the fluorophore concentration in the proximity of the refractive index step change. The method requires that the reference and sample objects have the same geometry and refractive index. The best results were obtained when the sample objects were also used for reference since small differences such as uneven surfaces will result in a different extent of aberration.

  5. Refractive Errors in Patients with Migraine Headache.

    PubMed

    Gunes, Alime; Demirci, Seden; Tok, Levent; Tok, Ozlem; Koyuncuoglu, Hasan; Yurekli, Vedat Ali

    2016-01-01

    To evaluate refractive errors in patients with migraine headache and to compare with healthy subjects. This prospective case-control study includes patients with migraine and age- and sex-matched healthy subjects. Clinical and demographic characteristics of the patients were noted. Detailed ophthalmological examinations were performed containing spherical refractive error, astigmatic refractive error, spherical equivalent (SE), anisometropia, best-corrected visual acuity, intraocular pressure, slit lamp biomicroscopy, fundus examination, axial length, anterior chamber depth, and central corneal thickness. Spectacle use in migraine and control groups was compared. Also, the relationship between refractive components and migraine headache variables was investigated. Seventy-seven migraine patients with mean age of 33.27 ± 8.84 years and 71 healthy subjects with mean age of 31.15 ± 10.45 years were enrolled (p = 0.18). The migraine patients had higher degrees of astigmatic refractive error, SE, and anisometropia when compared with the control subjects (p = 0.01, p = 0.03, p = 0.02, respectively). Migraine patients may have higher degrees of astigmatism, SE, and anisometropia. Therefore, they should have ophthalmological examinations regularly to ensure that their refractive errors are appropriately corrected.

  6. High precision refractometry based on Fresnel diffraction from phase plates.

    PubMed

    Tavassoly, M Taghi; Naraghi, Roxana Rezvani; Nahal, Arashmid; Hassani, Khosrow

    2012-05-01

    When a transparent plane-parallel plate is illuminated at a boundary region by a monochromatic parallel beam of light, Fresnel diffraction occurs because of the abrupt change in phase imposed by the finite change in refractive index at the plate boundary. The visibility of the diffraction fringes varies periodically with changes in incident angle. The visibility period depends on the plate thickness and the refractive indices of the plate and the surrounding medium. Plotting the phase change versus incident angle or counting the visibility repetition in an incident-angle interval provides, for a given plate thickness, the refractive index of the plate very accurately. It is shown here that the refractive index of a plate can be determined without knowing the plate thickness. Therefore, the technique can be utilized for measuring plate thickness with high precision. In addition, by installing a plate with known refractive index in a rectangular cell filled with a liquid and following the described procedures, the refractive index of the liquid is obtained. The technique is applied to measure the refractive indices of a glass slide, distilled water, and ethanol. The potential and merits of the technique are also discussed.

  7. [Modeling and Simulation of Spectral Polarimetric BRDF].

    PubMed

    Ling, Jin-jiang; Li, Gang; Zhang, Ren-bin; Tang, Qian; Ye, Qiu

    2016-01-01

    Under the conditions of the polarized light, The reflective surface of the object is affected by many factors, refractive index, surface roughness, and so the angle of incidence. For the rough surface in the different wavelengths of light exhibit different reflection characteristics of polarization, a spectral polarimetric BRDF based on Kirchhof theory is proposee. The spectral model of complex refraction index is combined with refraction index and extinction coefficient spectral model which were got by using the known complex refraction index at different value. Then get the spectral model of surface roughness derived from the classical surface roughness measuring method combined with the Fresnel reflection function. Take the spectral model of refraction index and roughness into the BRDF model, then the spectral polarimetirc BRDF model is proposed. Compare the simulation results of the refractive index varies with wavelength, roughness is constant, the refraction index and roughness both vary with wavelength and origin model with other papers, it shows that, the spectral polarimetric BRDF model can show the polarization characteristics of the surface accurately, and can provide a reliable basis for the application of polarization remote sensing, and other aspects of the classification of substances.

  8. On the Immersion Liquid Evaporation Method Based on the Dynamic Sweep of Magnitude of the Refractive Index of a Binary Liquid Mixture: A Case Study on Determining Mineral Particle Light Dispersion.

    PubMed

    Niskanen, Ilpo; Räty, Jukka; Peiponen, Kai-Erik

    2017-07-01

    This is a feasibility study of a modified immersion liquid technique for determining the refractive index of micro-sized particles. The practical challenge of the traditional liquid immersion method is to find or produce a suitable host liquid whose refractive index equals that of a solid particle. Usually, the immersion liquid method uses a set of immersion liquids with different refractive indices or continuously mixes two liquids with different refractive indices, e.g., using a pumping system. Here, the phenomenon of liquid evaporation has been utilized in defining the time-dependent refractive index variation of the host liquid. From the spectral transmittance data measured during the evaporation process, the refractive index of a solid particle in the host liquid can be determined as a function of the wavelength. The method was tested using calcium fluoride (CaF 2 ) particles with an immersion liquid mixed from diethyl ether and diffusion pump fluid. The dispersion data obtained were consistent with the literature values thus indicating the proper functioning of the proposed procedure.

  9. Refraction in Terms of the Deviation of the Light.

    ERIC Educational Resources Information Center

    Goldberg, Fred M.

    1985-01-01

    Discusses refraction in terms of the deviation of light. Points out that in physics courses where very little mathematics is used, it might be more suitable to describe refraction entirely in terms of the deviation, rather than by introducing Snell's law. (DH)

  10. GRAVSAT/GEOPAUSE refraction study

    NASA Technical Reports Server (NTRS)

    Llewellyn, S. K.

    1977-01-01

    A ground station network tracked a high altitude spacecraft which in turn tracked a low orbiting satellite. Orbit data are relayed back to the ground stations. A refraction study was performed on this configuration to compute ionospheric and tropospheric refraction effects along the satellite and ground links.

  11. Refractive index sensor based on optical fiber end face using pulse reference-based compensation technique

    NASA Astrophysics Data System (ADS)

    Bian, Qiang; Song, Zhangqi; Zhang, Xueliang; Yu, Yang; Chen, Yuzhong

    2018-03-01

    We proposed a refractive index sensor based on optical fiber end face using pulse reference-based compensation technique. With good compensation effect of this compensation technique, the power fluctuation of light source, the change of optic components transmission loss and coupler splitting ratio can be compensated, which largely reduces the background noise. The refractive index resolutions can achieve 3.8 × 10-6 RIU and1.6 × 10-6 RIU in different refractive index regions.

  12. Rigorous theoretical framework for particle sizing in turbid colloids using light refraction.

    PubMed

    García-Valenzuela, Augusto; Barrera, Rubén G; Gutierrez-Reyes, Edahí

    2008-11-24

    Using a non-local effective-medium approach, we analyze the refraction of light in a colloidal medium. We discuss the theoretical grounds and all the necessary precautions to design and perform experiments to measure the effective refractive index in dilute colloids. As an application, we show that it is possible to retrieve the size of small dielectric particles in a colloid by measuring the complex effective refractive index and the volume fraction occupied by the particles.

  13. Refractive indices of CaF2 single crystals under elastic shock loading

    NASA Astrophysics Data System (ADS)

    Li, Y.; Zhou, X. M.; Liu, C. L.; Luo, S. N.

    2017-07-01

    Refractive indices and Hugoniots of CaF2 single crystals are investigated by laser displacement interferometry under shock loading below 5 GPa. Birefringence is observed for the [110] loading. We obtain the Hugoniot equation of states for [100], [110] and [111], and refractive indices for these orientations with consideration of their polarization. The measured refractive indices are in reasonable agreement with predictions based on the piezo-optic theory, and are used to refine the elasto-optic coefficients.

  14. Atmospheric refraction effects on baseline error in satellite laser ranging systems

    NASA Technical Reports Server (NTRS)

    Im, K. E.; Gardner, C. S.

    1982-01-01

    Because of the mathematical complexities involved in exact analyses of baseline errors, it is not easy to isolate atmospheric refraction effects; however, by making certain simplifying assumptions about the ranging system geometry, relatively simple expressions can be derived which relate the baseline errors directly to the refraction errors. The results indicate that even in the absence of other errors, the baseline error for intercontinental baselines can be more than an order of magnitude larger than the refraction error.

  15. Determination of astronomical refraction near the horizon in different seasons of the year

    NASA Technical Reports Server (NTRS)

    Vasilenko, N. A.

    1974-01-01

    The results are presented of astronomical refraction measurements for zenith distances of 80-90 degrees performed in different seasons with a two inch universal instrument. The differences between observed and calculated refraction were found to exhibit seasonal variations, and the results were compared with data of atmospheric aerologic soundings. The great departures in observed refraction from that calculated with the Pulkovo tables were ascribed to temperature gradient changes within the ground kilometer layer of atmosphere.

  16. Determination of refractive indices of opaque rough surfaces

    NASA Astrophysics Data System (ADS)

    Destouches, Nathalie; Deumié, Carole; Giovannini, Hugues; Amra, Claude

    2004-02-01

    The refractive indices of optical materials are usually determined from spectrophotometric andellipsometric measurements of specular beams. When the roughness of the interfaces increases, the energy in the specularly reflected and transmitted beams decreases and scattering becomes predominant. For strong roughness (compared to the incident wavelength) a surface does not exhibit specular reflection or transmission, making difficult the determination of the refractive index. We describe two techniques, based on scattering measurements, that one can use to determine the refractive indices of opaque inhomogeneous media.

  17. Modulation of polymer refractive indices with diamond nanoparticles for metal-free multilayer film mirrors.

    PubMed

    Ogata, Tomonari; Yagi, Ryohei; Nakamura, Nozomi; Kuwahara, Yutaka; Kurihara, Seiji

    2012-08-01

    Modulation of the refractive index of a polymer was achieved by combining it with diamond nanoparticles (NDs). The increase in the refractive index was controlled by the amount of NDs added, according to the Lorentz-Lorenz equation. The refractive index of poly(vinyl alcohol) (PVA), which was used as the base polymer, increased from 1.52 to 1.88. A multilayer film consisting of alternating layers of ND-PVA composite and poly(methyl methacrylate) exhibited ca. 80% reflectance with 10 bilayers.

  18. Optical Properties of Si, Ge, GaAs, GaSb, InAs, and InP at Elevated Temperatures

    DTIC Science & Technology

    2010-03-01

    transmitted, and an absorbed (or scattered) component. The reflectance can be defined in terms of the index of refraction of the media on either side...of the interface. If the index of refraction of the material is n and the material is surrounded by air (nair ≈ 1), then the reflectance for near...the absorption coefficient and t is the sample thickness. 9 Since R depends on the refractive index and the refractive index depends on the

  19. Negative refractive index, perfect lenses and checkerboards: Trapping and imaging effects in folded optical spaces

    NASA Astrophysics Data System (ADS)

    Guenneau, Sébastien; Ramakrishna, S. Anantha

    2009-06-01

    Newly discovered metamaterials have opened new vistas for better control of light via negative refraction, whereby light refracts in the "wrong" manner. These are dielectric and metallic composite materials structured at subwavelength lengthscales. Their building blocks consist of local resonators such as conducting thin bars and split rings driving the material parameters such as the dielectric permittivity and magnetic permeability to negative (complex) values. Combined together, these structural elements can bring about a (complex valued) negative effective refractive index for the Snell-Descartes law and result in negative refraction of radiation. Negative refractive index materials can support a host of surface plasmon states for both polarizations of light. This makes possible unique effects such as imaging with subwavelength image resolution through the Pendry-Veselago slab lens. Other geometries have also been investigated, such as cylindrical or spherical lenses that enable a magnification of images with subwavelength resolution. Superlenses of three-fold (equilateral triangle), four-fold (square) and six-fold (hexagonal) geometry allow for multiple images, respectively two, three, and five. Generalization to rectangular and triangular checkerboards consisting of alternating cells of positive and negative refractive index represents a very singular situation in which the density of modes diverges at the corners, with an infinity of images. Sine-cosecant anisotropic heterogeneous square and triangular checkerboards can be respectively mapped onto three-dimensional cubic and icosahedral corner lenses consisting of alternating positive and negative refractive regions. All such systems with corners between negative and positive refractive media display very singular behavior with the local density of states becoming infinitely large at the corner, in the limit of no dissipation. We investigate all of these, using the unifying viewpoint of transformation optics. To cite this article: S. Guenneau, S.A. Ramakrishna, C. R. Physique 10 (2009).

  20. Refractive, corneal and ocular residual astigmatism: distribution in a German population and age-dependency - the Gutenberg health study.

    PubMed

    Schuster, Alexander Karl-Georg; Pfeiffer, Norbert; Schulz, Andreas; Hoehn, René; Ponto, Katharina A; Wild, Philipp S; Blettner, Maria; Beutel, Manfred E; Lackner, Karl J; Münzel, Thomas; Mirshahi, Alireza

    2017-12-01

    Worldwide, the most frequent cause of visual impairment is uncorrected refractive error. This analysis focused on the distribution and associations of refractive, corneal and ocular residual astigmatism. As part of the Gutenberg Health study, a population-based cross-sectional study was conducted in the general population of Germany. A comprehensive ophthalmological examination including refraction, tonometry, and Scheimpflug imaging of the anterior cornea (Pachycam) was performed. In addition to the magnitude and type (with-the-rule, against-the-rule, oblique) of the refractive or corneal astigmatism, we calculated the vector components (J 0 , J 45 ) of both astigmatisms and calculated the ocular residual astigmatism. We performed multiple quantile regression analysis to evaluate the factors associated with refractive, corneal and ocular residual astigmatisms. A total of 13,558 subjects (49% female) with a mean age of 54.0 years (range 35-74 years) were included in this study. The prevalence of refractive astigmatism (>1.0D) was 13.0% in right eyes and 12.0% in left eyes, and 85% of these subjects wore spectacles. The distribution of refractive astigmatism showed a two-peak distribution with high astigmatism for with-the-rule and against-the-rule astigmatism. The associated factors were corneal curvature, age and sex for the different astigmatisms (p < 0.001). We analyzed the prevalence of different astigmatisms within a European population. We confirmed a shift with aging from with-the-rule to against-the-rule astigmatism to refractive and corneal astigmatism. Astigmatism has a large impact on visual perception; more than 85% of people with astigmatism over one diopter wore glasses for distance vision.

  1. The Effect of Lens Sphere and Cylinder Power on Residual Astigmatism and Its Resolution After Toric Intraocular Lens Implantation.

    PubMed

    Berdahl, John P; Hardten, David R; Kramer, Brent A; Potvin, Richard

    2017-03-01

    To analyze correlations between residual refractive cylinder (and its correction through lens reorientation) with the sphere and cylinder power of the toric intraocular lens (IOL) implanted. An online toric back-calculator (www.astigmatismfix.com) allows users to input toric IOL planning data, along with postoperative IOL orientation and refractive results; these data are used to determine the optimal orientation of the IOL to reduce refractive astigmatism. This was a retrospective data analysis; aggregate historical data were extracted from this calculator to investigate the relationship between residual refractive astigmatism and IOL cylinder and sphere power. A total of 12,812 records, 4,619 of which included IOL sphere power, were available for analysis. There was no significant effect of sphere power on residual refractive astigmatism (P = .25), but lower IOL cylinder powers were associated with significantly lower residual refractive astigmatism (P < .05). The difference between the intended and ideal orientation was higher in the lower IOL cylinder power groups (P < .01). Overcorrection of astigmatism was significantly more likely with higher IOL cylinder power (P < .01), but not with sphere power (P = .33). Reorientation to correct residual refractive cylinder to less than 0.50 diopters (D) was more successful with IOL cylinder powers of 1.50 D or less (P < .01); IOL sphere power had no apparent effect. There were significant effects of IOL cylinder power on residual refractive astigmatism, the difference between intended and ideal orientation, the likelihood of overcorrection, and the likelihood of astigmatism reduction with lens reorientation. IOL sphere power appeared to have no such effects. [J Refract Surg. 2017;33(3):157-162.]. Copyright 2017, SLACK Incorporated.

  2. Myopic refractive shift represents dense nuclear sclerosis and thin lens in lenticular myopia.

    PubMed

    Cho, Yang Kyung; Huang, Wei; Nishimura, Eiichi

    2013-09-01

    It is not rare to meet unilateral nuclear sclerotic cataracts with myopic refractive changes (lenticular myopia) compared with the fellow eye in the ophthalmic examination of patients with decreased visual acuity. To determine the relationship between the myopic refractive changes and interocular differences of parameters, we investigated the interocular differences of ocular parameters between a lenticular myopic eye and the fellow eye. This retrospective study included 68 eyes of 34 patients, who showed unilateral lenticular myopia. We compared the dimensions of ocular component, such as anterior chamber depth, anterior chamber volume, lens thickness, vitreous chamber depth, lens position, lens density of nuclear sclerosis, anterior lens curvature and myopic refractive changes (spherical equivalent refraction) between the lenticular myopic eye and the myopic refractive change were examined. Statistically significant differences were found between the lenticular myopic eye and the fellow eye for anterior chamber depth (p = 0.015) anterior chamber volume (p = 0.031), lens thickness (p < 0.001), lens density of the nuclear sclerosis (p < 0.001) and the spherical equivalent myopic refractive changes (p < 0.001). Based on univariate analysis, the interocular difference in spherical equivalent refraction was significantly correlated with interocular differences of the density of the nuclear sclerosis (r = 0.79, p < 0.001), lens thickness (r = -0.70, p < 0.001) and vitreous chamber depth (r = 0.43, p = 0.012). Based on multiple regression analysis, the interocular difference in spherical equivalent refraction was significantly correlated with interocular differences of density of nuclear sclerosis (p < 0.001) and lens thickness (p = 0.007). The difference in myopic spherical change reflects the differences in the severity of nuclear sclerosis and lens thickness between the lenticular myopic eye and the fellow eye. © 2013 The Authors. Clinical and Experimental Optometry © 2013 Optometrists Association Australia.

  3. Refractive accuracy with light-adjustable intraocular lenses.

    PubMed

    Villegas, Eloy A; Alcon, Encarna; Rubio, Elena; Marín, José M; Artal, Pablo

    2014-07-01

    To evaluate efficacy, predictability, and stability of refractive treatments using light-adjustable intraocular lenses (IOLs). University Hospital Virgen de la Arrixaca, Murcia, Spain. Prospective nonrandomized clinical trial. Eyes with a light-adjustable IOL (LAL) were treated with spatial intensity profiles to correct refractive errors. The effective changes in refraction in the light-adjustable IOL after every treatment were estimated by subtracting those in the whole eye and the cornea, which were measured with a Hartmann-Shack sensor and a corneal topographer, respectively. The refractive changes in the whole eye and light-adjustable IOL, manifest refraction, and visual acuity were obtained after every light treatment and at the 3-, 6-, and 12-month follow-ups. The study enrolled 53 eyes (49 patients). Each tested light spatial pattern (5 spherical; 3 astigmatic) produced a different refractive change (P<.01). The combination of 2 light adjustments induced a maximum change in spherical power of the light-adjustable IOL of between -1.98 diopters (D) and +2.30 D and in astigmatism of up to -2.68 D with axis errors below 9 degrees. Intersubject variability (standard deviation) ranged between 0.10 D and 0.40 D. The 2 required lock-in procedures induced a small myopic shift (range +0.01 to +0.57 D) that depended on previous adjustments. Light-adjustable IOL implantation achieved accurate refractive outcomes (around emmetropia) with good uncorrected distance visual acuity, which remained stable over time. Further refinements in nomograms and in the treatment's protocol would improve the predictability of refractive and visual outcomes with these IOLs. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2014 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  4. Evaluation of the auto-refraction function of the Nidek OPD-Scan III.

    PubMed

    McGinnigle, Samantha; Naroo, Shehzad A; Eperjesi, Frank

    2014-03-01

    The aim was to evaluate the validity and repeatability of the auto-refraction function of the Nidek OPD-Scan III (Nidek Technologies, Gamagori, Japan) compared with non-cycloplegic subjective refraction. The Nidek OPD-Scan III is a new aberrometer/corneal topographer workstation based on the skiascopy principle. It combines a wavefront aberrometer, topographer, autorefractor, auto keratometer and pupillometer/pupillographer. Objective refraction results obtained using the Nidek OPD-Scan III were compared with non-cycloplegic subjective refraction for 108 eyes of 54 participants (29 female) with a mean age of 23.7 ± 9.5 years. Intra-session and inter-session variability were assessed on 14 subjects (28 eyes). The Nidek OPD-Scan III gave slightly more negative readings than results obtained by subjective refraction (Nidek mean difference -0.19 ± 0.36 DS, p < 0.01 for sphere; -0.19 ± 0.35 DS, p < 0.01 for mean spherical equivalent; -0.002 ± 0.23 DC, p = 0.91 for cylinder; -0.06 ± 0.38 DC, p = 0.30 for J0 and -0.36 ± 0.31 DC for J45, p = 0.29). Auto-refractor results for 74 per cent of spherical readings and 60 per cent of cylindrical powers were within ± 0.25 of subjective refraction. There was high intra-session and inter-session repeatability for all parameters; 90 per cent of inter-session repeatability results were within 0.25 D. The Nidek OPD-Scan III gives valid and repeatable measures of objective refraction when compared with non-cycloplegic subjective refraction. © 2013 The Authors. Clinical and Experimental Optometry © 2013 Optometrists Association Australia.

  5. Improved algorithm of ray tracing in ICF cryogenic targets

    NASA Astrophysics Data System (ADS)

    Zhang, Rui; Yang, Yongying; Ling, Tong; Jiang, Jiabin

    2016-10-01

    The high precision ray tracing inside inertial confinement fusion (ICF) cryogenic targets plays an important role in the reconstruction of the three-dimensional density distribution by algebraic reconstruction technique (ART) algorithm. The traditional Runge-Kutta methods, which is restricted by the precision of the grid division and the step size of ray tracing, cannot make an accurate calculation in the case of refractive index saltation. In this paper, we propose an improved algorithm of ray tracing based on the Runge-Kutta methods and Snell's law of refraction to achieve high tracing precision. On the boundary of refractive index, we apply Snell's law of refraction and contact point search algorithm to ensure accuracy of the simulation. Inside the cryogenic target, the combination of the Runge-Kutta methods and self-adaptive step algorithm are employed for computation. The original refractive index data, which is used to mesh the target, can be obtained by experimental measurement or priori refractive index distribution function. A finite differential method is performed to calculate the refractive index gradient of mesh nodes, and the distance weighted average interpolation methods is utilized to obtain refractive index and gradient of each point in space. In the simulation, we take ideal ICF target, Luneberg lens and Graded index rod as simulation model to calculate the spot diagram and wavefront map. Compared the simulation results to Zemax, it manifests that the improved algorithm of ray tracing based on the fourth-order Runge-Kutta methods and Snell's law of refraction exhibits high accuracy. The relative error of the spot diagram is 0.2%, and the peak-to-valley (PV) error and the root-mean-square (RMS) error of the wavefront map is less than λ/35 and λ/100, correspondingly.

  6. [Polar and non polar notations of refraction].

    PubMed

    Touzeau, O; Gaujoux, T; Costantini, E; Borderie, V; Laroche, L

    2010-01-01

    Refraction can be expressed by four polar notations which correspond to four different combinations of spherical or cylindrical lenses. Conventional expressions of refraction (plus and minus cylinder notation) are described by sphere, cylinder, and axis. In the plus cylinder notation, the axis visualizes the most powerful meridian. The axis usually corresponds to the bow tie axis in curvature maps. Plus cylinder notation is also valuable for all relaxing procedures (i.e., selective suture ablation, arcuate keratotomy, etc.). In the cross-cylinder notation, two orthogonal cylinders can describe (without the sphere component) the actual refraction of both the principal meridians. This notation must be made before performing the vertex calculation. Using an association of a Jackson cross-cylinder and a spherical equivalent, refraction can be broken down into two pure components: astigmatism and sphere. All polar notations of refraction may perfectly characterize a single refraction but are not suitable for statistical analysis, which requires nonpolar expression. After doubling the axis, a rectangular projection breaks down the Jackson cross-cylinder, which has a polar axis, into two Jackson cross-cylinders on the 0 degrees /90 degrees and 45 degrees /135 degrees axis. This procedure results in the loss of the directional nature of the data. Refraction can be written in a nonpolar notation by three rectangular coordinates (x,y,z), which can also represent the spherocylinder by one point in a dioptric space. These three independent (orthogonal) variables have a concrete optical significance: a spherical component, a direct/inverse (WTR/ATR) component, and an oblique component of the astigmatism. Finally, nonpolar notations are useful for statistical analysis and graphical representation of refraction. Copyright (c) 2009 Elsevier Masson SAS. All rights reserved.

  7. Prevalence of the refractive errors by age and gender: the Mashhad eye study of Iran.

    PubMed

    Ostadimoghaddam, Hadi; Fotouhi, Akbar; Hashemi, Hassan; Yekta, Abbasali; Heravian, Javad; Rezvan, Farhad; Ghadimi, Hamidreza; Rezvan, Bijan; Khabazkhoob, Mehdi

    2011-11-01

    Refractive errors are a common eye problem. Considering the low number of population-based studies in Iran in this regard, we decided to determine the prevalence rates of myopia and hyperopia in a population in Mashhad, Iran. Cross-sectional population-based study. Random cluster sampling. Of 4453 selected individuals from the urban population of Mashhad, 70.4% participated. Refractive error was determined using manifest (age > 15 years) and cycloplegic refraction (age ≤ 15 years). Myopia was defined as a spherical equivalent of -0.5 diopter or worse. An spherical equivalent of +0.5 diopter or worse for non-cycloplegic refraction and an spherical equivalent of +2 diopter or worse for cycloplegic refraction was used to define hyperopia. Prevalence of refractive errors. The prevalence of myopia and hyperopia in individuals ≤ 15 years old was 3.64% (95% CI: 2.19-5.09) and 27.4% (95% CI: 23.72-31.09), respectively. The same measurements for subjects > 15 years of age was 22.36% (95% CI: 20.06-24.66) and 34.21% (95% CI: 31.57-36.85), respectively. Myopia was found to increase with age in individuals ≤ 15 years and decrease with age in individuals > 15 years of age. The rate of hyperopia showed a significant increase with age in individuals > 15 years. The prevalence of astigmatism was 25.64% (95% CI: 23.76-27.51). In children and the elderly, hyperopia is the most prevalent refractive error. After hyperopia, astigmatism is also of importance in older ages. Age is the most important demographic factor associated with different types of refractive errors. © 2011 The Authors. Clinical and Experimental Ophthalmology © 2011 Royal Australian and New Zealand College of Ophthalmologists.

  8. The prevalence of uncorrected refractive errors in underserved rural areas.

    PubMed

    Hashemi, Hassan; Abbastabar, Hedayat; Yekta, Abbasali; Heydarian, Samira; Khabazkhoob, Mehdi

    2017-12-01

    To determine the prevalence of uncorrected refractive errors, need for spectacles, and the determinants of unmet need in underserved rural areas of Iran. In a cross-sectional study, multistage cluster sampling was done in 2 underserved rural areas of Iran. Then, all subjects underwent vision testing and ophthalmic examinations including the measurement of uncorrected visual acuity (UCVA), best corrected visual acuity, visual acuity with current spectacles, auto-refraction, retinoscopy, and subjective refraction. Need for spectacles was defined as UCVA worse than 20/40 in the better eye that could be corrected to better than 20/40 with suitable spectacles. Of the 3851 selected individuals, 3314 participated in the study. Among participants, 18.94% [95% confidence intervals (CI): 13.48-24.39] needed spectacles and 11.23% (95% CI: 7.57-14.89) had an unmet need. The prevalence of need for spectacles was 46.8% and 23.8% in myopic and hyperopic participants, respectively. The prevalence of unmet need was 27% in myopic, 15.8% in hyperopic, and 25.46% in astigmatic participants. Multiple logistic regression showed that education and type of refractive errors were associated with uncorrected refractive errors; the odds of uncorrected refractive errors were highest in illiterate participants, and the odds of unmet need were 12.13, 5.1, and 4.92 times higher in myopic, hyperopic and astigmatic participants as compared with emmetropic individuals. The prevalence of uncorrected refractive errors was rather high in our study. Since rural areas have less access to health care facilities, special attention to the correction of refractive errors in these areas, especially with inexpensive methods like spectacles, can prevent a major proportion of visual impairment.

  9. Prevalence of laser vision correction in ophthalmologists who perform refractive surgery.

    PubMed

    Kezirian, Guy M; Parkhurst, Gregory D; Brinton, Jason P; Norden, Richard A

    2015-09-01

    To determine the prevalence of laser corneal refractive surgery (laser vision correction [LVC]) among ophthalmologists who perform these procedures and to assess the willingness of these ophthalmologists to recommend LVC to immediate family members. Online survey with results analyzed at Surgivision Consultants, Inc., Scottsdale, Arizona, USA. Prospective randomized questionnaire study. The 22-question Global Survey on Refractive Surgery in Refractive Surgeons was sent by e-mail to 250 ophthalmologists randomly selected from a database of 2441 ophthalmologists known to have performed LVC at some point in the past decade. Responses were solicited by e-mail, with subsequent telephone reminders to nonresponders. Responses were received from 248 (99.2%) of 250 queried individuals, of which 232 (92.8%) met the protocol criteria of currently working as refractive surgeons. Of the 232 subjects, 161 (69.4%) reported that they had refractive errors potentially amenable to treatment with LVC, not including presbyopia. Of the 161 ophthalmologists with treatable refractive errors, 54 (33.5%) reported they were not candidates for LVC for a variety of reasons and 107 (66.5%) reported they were candidates for LVC. Of the LVC candidates, 62.6% reported that they had an LVC procedure in their own eyes. Of the overall 232 subjects, more than 90% recommend LVC for adult members of their immediate family. Ophthalmologists who perform LVC were significantly more likely than the general population to have LVC in their own eyes. The prevalence of refractive errors was significantly higher among ophthalmologists performing refractive surgery than in the general population. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  10. Evaluation of a quantitative structure-property relationship (QSPR) for predicting mid-visible refractive index of secondary organic aerosol (SOA).

    PubMed

    Redmond, Haley; Thompson, Jonathan E

    2011-04-21

    In this work we describe and evaluate a simple scheme by which the refractive index (λ = 589 nm) of non-absorbing components common to secondary organic aerosols (SOA) may be predicted from molecular formula and density (g cm(-3)). The QSPR approach described is based on three parameters linked to refractive index-molecular polarizability, the ratio of mass density to molecular weight, and degree of unsaturation. After computing these quantities for a training set of 111 compounds common to atmospheric aerosols, multi-linear regression analysis was conducted to establish a quantitative relationship between the parameters and accepted value of refractive index. The resulting quantitative relationship can often estimate refractive index to ±0.01 when averaged across a variety of compound classes. A notable exception is for alcohols for which the model consistently underestimates refractive index. Homogenous internal mixtures can conceivably be addressed through use of either the volume or mole fraction mixing rules commonly used in the aerosol community. Predicted refractive indices reconstructed from chemical composition data presented in the literature generally agree with previous reports of SOA refractive index. Additionally, the predicted refractive indices lie near measured values we report for λ = 532 nm for SOA generated from vapors of α-pinene (R.I. 1.49-1.51) and toluene (R.I. 1.49-1.50). We envision the QSPR method may find use in reconstructing optical scattering of organic aerosols if mass composition data is known. Alternatively, the method described could be incorporated into in models of organic aerosol formation/phase partitioning to better constrain organic aerosol optical properties.

  11. Assessing the accuracy and feasibility of a refractive error screening program conducted by school teachers in pre-primary and primary schools in Thailand.

    PubMed

    Teerawattananon, Kanlaya; Myint, Chaw-Yin; Wongkittirux, Kwanjai; Teerawattananon, Yot; Chinkulkitnivat, Bunyong; Orprayoon, Surapong; Kusakul, Suwat; Tengtrisorn, Supaporn; Jenchitr, Watanee

    2014-01-01

    As part of the development of a system for the screening of refractive error in Thai children, this study describes the accuracy and feasibility of establishing a program conducted by teachers. To assess the accuracy and feasibility of screening by teachers. A cross-sectional descriptive and analytical study was conducted in 17 schools in four provinces representing four geographic regions in Thailand. A two-staged cluster sampling was employed to compare the detection rate of refractive error among eligible students between trained teachers and health professionals. Serial focus group discussions were held for teachers and parents in order to understand their attitude towards refractive error screening at schools and the potential success factors and barriers. The detection rate of refractive error screening by teachers among pre-primary school children is relatively low (21%) for mild visual impairment but higher for moderate visual impairment (44%). The detection rate for primary school children is high for both levels of visual impairment (52% for mild and 74% for moderate). The focus group discussions reveal that both teachers and parents would benefit from further education regarding refractive errors and that the vast majority of teachers are willing to conduct a school-based screening program. Refractive error screening by health professionals in pre-primary and primary school children is not currently implemented in Thailand due to resource limitations. However, evidence suggests that a refractive error screening program conducted in schools by teachers in the country is reasonable and feasible because the detection and treatment of refractive error in very young generations is important and the screening program can be implemented and conducted with relatively low costs.

  12. Refractive index measurement of the mouse crystalline lens using optical coherence tomography

    PubMed Central

    Chakraborty, Ranjay; Lacy, Kip D.; Tan, Christopher C.; Park, Han na; Pardue, Machelle T.

    2014-01-01

    In recent years, there has been a growing interest for using mouse models in refractive development and myopia research. The crystalline lens is a critical optical component of the mouse eye that occupies greater than 50% of the ocular space, and significant increases in thickness with age. However, changes in refractive index of the mouse crystalline lens are less known. In this study, we examined the changes in thickness and refractive index of the mouse crystalline lens for two different strains, wild-type (WT) and a nyx mutant (nob) over the course of normal visual development or after form deprivation. Refractive index and lens thickness measurements were made on ex vivo lens using spectral domain optical coherence tomography (SD-OCT). Comparison of refractive index measurements on 5 standard ball lenses using the SD-OCT and their known refractive indices (manufacturer provided) indicated good precision (intra-class correlation coefficient, 0.998 and Bland-Altman coefficient of repeatability, 0.116) of the SD-OCT to calculate mouse lens refractive index ex vivo. During normal visual development, lens thickness increased significantly with age for three different cohorts of mice, aged 4 (average thickness from both eyes; WT: 1.78 ± 0.03, nob: 1.79 ± 0.08 mm), 10 (WT: 2.02 ± 0.05, nob: 2.01 ± 0.04 mm) and 16 weeks (WT: 2.12 ± 0.06, nob: 2.09 ± 0.06 mm, p<0.001). Lens thickness was not significantly different between the two strains at any age (p=0.557). For mice with normal vision, refractive index for isolated crystalline lenses in nob mice was significantly greater than WT mice (mean for all ages; WT: 1.42 ± 0.01, nob: 1.44 ± 0.001, p<0.001). After 4 weeks of form deprivation to the right eye using a skull-mounted goggling apparatus, a thinning of the crystalline lens was observed in both right and left eyes of goggled animals compared to their naïve controls (average from both the right and the left eye) for both strains (p=0.052). In form deprived mice, lens refractive index was significantly different between the goggled animals and non-goggled naïve controls in nob mice, but not in WT mice (p=0.009). Both eyes of goggled nob mice had significantly greater lens refractive index (goggled, 1.49 ± 0.01; opposite, 1.47 ± 0.03) compared to their naïve controls (1.45 ± 0.02, p<0.05). The results presented here suggest that there are genetic differences in the crystalline lens refractive index of the mouse eye, and that the lens refractive index in mice significantly increase with form deprivation. Research applications requiring precise optical measurements of the mouse eye should take these lens refractive indices into account when interpreting SD-OCT data. PMID:24939747

  13. Complex Refractive Index of Ammonium Nitrate in the 2-20 micron Spectral Range

    NASA Technical Reports Server (NTRS)

    Jarzembski, Maurice A.; Norman, Mark L.; Fuller, Kirk A.; Srivastava, Vandana; Cutten, Dean R.

    2002-01-01

    Using high resolution Fourier Transform Infrared Spectroscopy (FTIR) absorbance/transmittance spectral data for ammonium sulfate (AMS), calcium carbonate (CAC) and ammonium nitrate (AMN), comparisons were made with previously published complex refractive indices data for AMS and CAC to infer experimental parameters to determine the imaginary refractive index for AMN in the infrared wavelength range from 2 to 20 microns. Kramers-Kronig mathematical relations were applied to calculate the real refractive index for the three compositions. Excellent agreement for AMS and CAC with the published values was found, validating the complex refractive indices obtained for AMN. Backscatter calculations using a lognormal size distribution for AMS, AMN, and CAC aerosols were performed to show differences in their backscattered spectra.

  14. Chirality-induced negative refraction in magnetized plasma

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Guo, B.

    2013-09-15

    Characteristic equations in magnetized plasma with chirality are derived in simple formulations and the dispersion relations for propagation parallel and perpendicular to the external magnetic field are studied in detail. With the help of the dispersion relations of each eigenwave, the author explores chirality-induced negative refraction in magnetized plasma and investigates the effects of parameters (i.e., chirality degree, external magnetic field, etc.) on the negative refraction. The results show that the chirality is the necessary and only one factor which leads to negative refraction without manipulating electrical permittivity and magnetic permeability. Both increasing the degree of chirality and reducing themore » external magnetic field can result in greater range negative refraction. Parameter dependence of the effects is calculated and discussed.« less

  15. The effect of UV irradiation on the refractive index modulation in photo-thermo-refractive glasses: Mechanisms and application

    NASA Astrophysics Data System (ADS)

    Chernakov, Dmitry I.; Sidorov, Alexander I.; Stolyarchuk, Maxim V.; Kozlova, Darya A.; Krykova, Victoria A.; Nikonorov, Nikolay V.

    2018-02-01

    It is shown experimentally that in photo-thermo-refractive glasses the transformation of charged silver subnanosized molecular clusters to neutral state by UV irradiation results in the increase of glass refractive index. The increment of the refractive index reaches Δn = 0.76·10-4. Computer simulation has shown that the polarizability of neutral molecular clusters is by 20-40% larger than of charged ones. The reason of this is the increase of electron density and volume of electron density surfaces during the transformation of molecular cluster to the neutral state. The transition molecular cluster from the ground state to the excited state also results in the increase of its polarizability.

  16. TiO2 surface functionalization of COC based planar waveguide Bragg gratings for refractive index sensing

    NASA Astrophysics Data System (ADS)

    Rosenberger, M.; Girschikofsky, M.; Förthner, M.; Belle, S.; Rommel, M.; Frey, L.; Schmauss, B.; Hellmann, R.

    2018-01-01

    We demonstrate the applicability of a planar waveguide Bragg grating in cyclo-olefin copolymer (COC) for refractive index sensing. The polymer planar waveguide Bragg grating fabricated using a single writing step technique is coated with a high-index layer of titanium dioxide (TiO2) leading to a distinct birefringence. This in turn results in the splitting of the Bragg reflection into two distinct Bragg wavelengths, which strongly differ regarding their refractive index sensitivities. Where one wavelength is only slightly affected by the ambient refractive index, the second Bragg peak shows a strong sensitivity. Furthermore, we investigate the temperature behaviour of the functionalized sensor and discuss it with respect to applications in refractive index sensing.

  17. Gradient polymer network liquid crystal with a large refractive index change.

    PubMed

    Ren, Hongwen; Xu, Su; Wu, Shin-Tson

    2012-11-19

    A simple approach for preparing gradient polymer network liquid crystal (PNLC) with a large refractive index change is demonstrated. To control the effective refractive index at a given cell position, we applied a voltage to a homogeneous cell containing LC/diacrylate monomer mixture to generate the desired tilt angle and then stabilize the LC orientation with UV-induced polymer network. By varying the applied voltage along with the cells' movement, a PNLC with a gradient refractive index distribution is obtained. In comparison with conventional approaches using patterned photomask or electrode, our method offers following advantages: large refractive index change, freedom to design specific index profile, and large panel capability. Potential applications include tunable-focus lenses, prism gratings, phase modulators, and other adaptive photonic devices.

  18. Electrically tunable negative refraction in core/shell-structured nanorod fluids.

    PubMed

    Su, Zhaoxian; Yin, Jianbo; Guan, Yanqing; Zhao, Xiaopeng

    2014-10-21

    We theoretically investigate optical refraction behavior in a fluid system which contains silica-coated gold nanorods dispersed in silicone oil under an external electric field. Because of the formation of a chain-like or lattice-like structure of dispersed nanorods along the electric field, the fluid shows a hyperbolic equifrequency contour characteristic and, as a result, all-angle broadband optical negative refraction for transverse magnetic wave propagation can be realized. We calculate the effective permittivity tensor of the fluid and verify the analysis using finite element simulations. We also find that the negative refractive index can vary with the electric field strength and external field distribution. Under a non-uniform external field, the gradient refraction behavior can be realized.

  19. Refractive index inversion based on Mueller matrix method

    NASA Astrophysics Data System (ADS)

    Fan, Huaxi; Wu, Wenyuan; Huang, Yanhua; Li, Zhaozhao

    2016-03-01

    Based on Stokes vector and Jones vector, the correlation between Mueller matrix elements and refractive index was studied with the result simplified, and through Mueller matrix way, the expression of refractive index inversion was deduced. The Mueller matrix elements, under different incident angle, are simulated through the expression of specular reflection so as to analyze the influence of the angle of incidence and refractive index on it, which is verified through the measure of the Mueller matrix elements of polished metal surface. Research shows that, under the condition of specular reflection, the result of Mueller matrix inversion is consistent with the experiment and can be used as an index of refraction of inversion method, and it provides a new way for target detection and recognition technology.

  20. Recovery of Peripheral Refractive Errors and Ocular Shape in Rhesus Monkeys (Macaca mulatta) with Experimentally Induced Myopia

    PubMed Central

    Huang, Juan; Hung, Li-Fang; Smith, Earl L.

    2012-01-01

    This study aimed to investigate the changes in ocular shape and relative peripheral refraction during the recovery from myopia produced by form deprivation (FD) and hyperopic defocus. FD was imposed in 6 monkeys by securing a diffuser lens over one eye; hyperopic defocus was produced in another 6 monkeys by fitting one eye with -3D spectacle. When unrestricted vision was re-established, the treated eyes recovered from the vision-induced central and peripheral refractive errors. The recovery of peripheral refractive errors was associated with corresponding changes in the shape of the posterior globe. The results suggest that vision can actively regulate ocular shape and the development of central and peripheral refractions in infant primates. PMID:23026012

  1. Study of optical nonlinearities in Se-Te-Bi thin films

    NASA Astrophysics Data System (ADS)

    Sharma, Ambika; Yadav, Preeti; Kumari, Anshu

    2014-04-01

    The present work reports the nonlinear refractive index of Se85-xTe15Bix thin films calculated by Ticha and Tichy relation. The nonlinear refractive index of Chalcogenide amorphous semiconductor is well correlated with the linear refractive index and WDD parameters which in turn depend on the density and molar volume of the system. The density of the system is calculated theoretical as well as experimentally by using Archimedes principle. The linear refractive index and WDD parameters are calculated using single transmission spectra in the spectral range of 400-1500 nm. It is observed that linear as well as nonlinear refractive index increases with Bi content. The results are analyzed on the basis of increasing polarizability due to larger radii of Bi.

  2. Phase and group refractive indices of air calculation by fitting of phase difference measured using a combination of laser and low-coherence interferometry

    NASA Astrophysics Data System (ADS)

    Pikálek, Tomáš; Šarbort, Martin; Číp, Ondřej; Pham, Minh Tuan; Lešundák, Adam; Pravdová, Lenka; Buchta, Zdeněk.

    2017-06-01

    The air refractive index is an important parameter in interferometric length measurements, since it substantially affects the measurement accuracy. We present a refractive index of air measurement method based on monitoring the phase difference between the ambient air and vacuum inside a permanently evacuated double-spaced cell. The cell is placed in one arm of the Michelson interferometer equipped with two light sources—red LED and HeNe laser, while the low-coherence and laser interference signals are measured separately. Both phase and group refractive indices of air can be calculated from the measured signals. The method was experimentally verified by comparing the obtained refractive index values with two different techniques.

  3. Anomalous incident-angle and elliptical-polarization rotation of an elastically refracted P-wave

    NASA Astrophysics Data System (ADS)

    Fa, Lin; Fa, Yuxiao; Zhang, Yandong; Ding, Pengfei; Gong, Jiamin; Li, Guohui; Li, Lijun; Tang, Shaojie; Zhao, Meishan

    2015-08-01

    We report a newly discovered anomalous incident-angle of an elastically refracted P-wave, arising from a P-wave impinging on an interface between two VTI media with strong anisotropy. This anomalous incident-angle is found to be located in the post-critical incident-angle region corresponding to a refracted P-wave. Invoking Snell’s law for a refracted P-wave provides two distinctive solutions before and after the anomalous incident-angle. For an inhomogeneously refracted and elliptically polarized P-wave at the anomalous incident-angle, its rotational direction experiences an acute variation, from left-hand elliptical to right-hand elliptical polarization. The new findings provide us an enhanced understanding of acoustical-wave scattering and lead potentially to widespread and novel applications.

  4. Measurement of Refractive Index Using a Michelson Interferometer.

    ERIC Educational Resources Information Center

    Fendley, J. J.

    1982-01-01

    Describes a novel and simple method of measuring the refractive index of transparent plates using a Michelson interferometer. Since it is necessary to use a computer program when determining the refractive index, undergraduates could be given the opportunity of writing their own programs. (Author/JN)

  5. String and Sticky Tape Experiments: Refractive Index of Liquids.

    ERIC Educational Resources Information Center

    Edge, R. D., Ed.

    1979-01-01

    Describes a simple method of measuring the refractive index of a liquid using a paper cup, a liquid, a pencil, and a ruler. Uses the ratio between the actual depth and the apparent depth of the cup to calculate the refractive index. (GA)

  6. Long range surface plasmon resonance (LRSPR) based highly sensitive refractive index sensor using Kretschmann prism coupling arrangement

    NASA Astrophysics Data System (ADS)

    Paliwal, Ayushi; Sharma, Anjali; Tomar, Monika; Gupta, Vinay

    2016-04-01

    Long range surface plasmon resonance (LRSPR) when exploited for sensing purpose exhibit less losses in comparison to the sensors based on conventional SPR technique leading to the development of highly sensitive refractive index sensor. In order to excite long range surface plasmon (LRSP) mode, a high refractive index prism is used as coupler and a thin metal layer is sandwiched between a dielectric having similar refractive index with that of another semi-infinite dielectric. LRSP mode has been excited in symmetric configuration where metal (Au) layer is sandwiched between the two similar refractive index dielectrics (LiF thin film and a fixed concentration of sugar solution) for realization of a refractive index sensor. When the concentration of sugar solution is slightly increased from 30% to 40%, the LRSPR angle increases from 64.6° to 67.9° and the sensor is found to be highly sensitive with sensitivity of 0.0911 °/(mg/dl).

  7. Reflection and Refraction of Acoustic Waves by a Shock Wave

    NASA Technical Reports Server (NTRS)

    Brillouin, J.

    1957-01-01

    The presence of sound waves in one or the other of the fluid regions on either side of a shock wave is made apparent, in the region under superpressure, by acoustic waves (reflected or refracted according to whether the incident waves lie in the region of superpressure or of subpressure) and by thermal waves. The characteristics of these waves are calculated for a plane, progressive, and uniform incident wave. In the case of refraction, the refracted acoustic wave can, according to the incidence, be plane, progressive, and uniform or take the form of an 'accompanying wave' which remains attached to the front of the shock while sliding parallel to it. In all cases, geometrical constructions permit determination of the kinematic characteristics of the reflected or refractive acoustic waves. The dynamic relationships show that the amplitude of the reflected wave is always less than that of the incident wave. The amplitude of the refracted wave, whatever its type, may in certain cases be greater than that of the incident wave.

  8. Spatial variation of stratospheric aerosol acidity and model refractive index - Implications of recent results

    NASA Technical Reports Server (NTRS)

    Russell, P. B.; Hamill, P.

    1984-01-01

    Recent experimental results indicate that little or no solid ammonium sulfate is present in background stratospheric aerosols. Other results allow straightforward calculation of sulfuric acid/water droplet properties (acidity, specific gravity, refractive index) as functions of stratospheric temperature and humidity. These results are combined with a variety of latitudinal and seasonal temperature and humidity profiles to obtain corresponding profiles of droplet properties. These profiles are used to update a previous model of stratospheric aerosol refractive index. The new model retains the simplifying approximation of vertically constant refractive index in the inner stratosphere, but has sulfuric acid/water refractive index values that significantly exceed the previously used room temperature values. Mean conversion ratios (e.g., extinction-to-number, backscatter-to-volume) obtained using Mie scattering calculations with the new refractive indices are very similar to those obtained for the old indices, because the effects of deleting ammonium sulfate and increasing acid indices tend to cancel each other.

  9. Effect of temperature rise and hydrostatic pressure on microbending loss and refractive index change in double-coated optical fiber

    NASA Astrophysics Data System (ADS)

    Seraji, Faramarz E.; Toutian, Golnoosh

    This paper presents an analysis of the effect of temperature rise and hydrostatic pressure on microbending loss, refractive index change, and stress components of a double-coated optical fiber by considering coating material parameters such as Young's modulus and the Poisson ratio. It is shown that, when temperature rises, the microbending loss and refractive index changes would decrease with increase of thickness of primary coating layer and will increase after passing through a minima. Increase of thickness of secondary coating layer causes the microbending loss and refractive index changes to decrease. We have shown that the temperature rise affecting the fiber makes the microbending loss and refractive index decrease, linearly. At a particular temperature, the microbending loss takes negative values, due to tensile pressure applied on the fiber. The increase of Young's modulus and the Poisson ratio of primary coating would lower the microbending loss and refractive index change whereas in the secondary coating layer, the condition reverses.

  10. Negative refraction, gain and nonlinear effects in hyperbolic metamaterials.

    PubMed

    Argyropoulos, Christos; Estakhri, Nasim Mohammadi; Monticone, Francesco; Alù, Andrea

    2013-06-17

    The negative refraction and evanescent-wave canalization effects supported by a layered metamaterial structure obtained by alternating dielectric and plasmonic layers is theoretically analyzed. By using a transmission-line analysis, we formulate a way to rapidly analyze the negative refraction operation for given available materials over a broad range of frequencies and design parameters, and we apply it to broaden the bandwidth of negative refraction. Our analytical model is also applied to explore the possibility of employing active layers for loss compensation. Nonlinear dielectrics can also be considered within this approach, and they are explored in order to add tunability to the optical response, realizing positive-to-zero-to-negative refraction at the same frequency, as a function of the input intensity. Our findings may lead to a better physical understanding and improvement of the performance of negative refraction and subwavelength imaging in layered metamaterials, paving the way towards the design of gain-assisted hyperlenses and tunable nonlinear imaging devices.

  11. Refraction error correction for deformation measurement by digital image correlation at elevated temperature

    NASA Astrophysics Data System (ADS)

    Su, Yunquan; Yao, Xuefeng; Wang, Shen; Ma, Yinji

    2017-03-01

    An effective correction model is proposed to eliminate the refraction error effect caused by an optical window of a furnace in digital image correlation (DIC) deformation measurement under high-temperature environment. First, a theoretical correction model with the corresponding error correction factor is established to eliminate the refraction error induced by double-deck optical glass in DIC deformation measurement. Second, a high-temperature DIC experiment using a chromium-nickel austenite stainless steel specimen is performed to verify the effectiveness of the correction model by the correlation calculation results under two different conditions (with and without the optical glass). Finally, both the full-field and the divisional displacement results with refraction influence are corrected by the theoretical model and then compared to the displacement results extracted from the images without refraction influence. The experimental results demonstrate that the proposed theoretical correction model can effectively improve the measurement accuracy of DIC method by decreasing the refraction errors from measured full-field displacements under high-temperature environment.

  12. Frequency comb calibrated frequency-sweeping interferometry for absolute group refractive index measurement of air.

    PubMed

    Yang, Lijun; Wu, Xuejian; Wei, Haoyun; Li, Yan

    2017-04-10

    The absolute group refractive index of air at 194061.02 GHz is measured in real time using frequency-sweeping interferometry calibrated by an optical frequency comb. The group refractive index of air is calculated from the calibration peaks of the laser frequency variation and the interference signal of the two beams passing through the inner and outer regions of a vacuum cell when the frequency of a tunable external cavity diode laser is scanned. We continuously measure the refractive index of air for 2 h, which shows that the difference between measured results and Ciddor's equation is less than 9.6×10-8, and the standard deviation of that difference is 5.9×10-8. The relative uncertainty of the measured refractive index of air is estimated to be 8.6×10-8. The data update rate is 0.2 Hz, making it applicable under conditions in which air refractive index fluctuates fast.

  13. Using a laser source to measure the refractive index of glass beads and Debye theory analysis.

    PubMed

    Li, Shui-Yan; Qin, Shuang; Li, Da-Hai; Wang, Qiong-Hua

    2015-11-20

    Using a monochromatic laser beam to illuminate a homogeneous glass bead, some rainbows will appear around it. This paper concentrates on the study of the scattering intensity distribution and the method of measuring the refractive index for glass beads based on the Debye theory. It is found that the first rainbow due to the scattering superposition of backward light of the low-refractive-index glass beads can be explained approximately with the diffraction, the external reflection plus the one internal reflection, while the second rainbow of high-refractive-index glass beads is due to the contribution from the diffraction, the external reflection, the direct transmission, and the two internal reflections. The scattering intensity distribution is affected by the refractive index, the radius of the glass bead, and the incident beam width. The effects of the refractive index and the glass bead size on the first and second minimum deviation angle position are analyzed in this paper. The results of the measurements agree very well with the specifications.

  14. Refractive index sensor based on a polymer fiber directional coupler for low index sensing.

    PubMed

    Lee, Kwang Jo; Liu, Xiaoqi; Vuillemin, Nelly; Lwin, Richard; Leon-Saval, Sergio G; Argyros, Alexander; Kuhlmey, Boris T

    2014-07-14

    We propose, numerically analyze and experimentally demonstrate a novel refractive index sensor specialized for low index sensing. The device is based on a directional coupler architecture implemented in a single microstructured polymer optical fiber incorporating two waveguides within it: a single-mode core and a satellite waveguide consisting of a hollow high-index ring. This hollow channel is filled with fluid and the refractive index of the fluid is detected through changes to the wavelength at which resonant coupling occurs between the two waveguides. The sensor design was optimized for both higher sensitivity and lower detection limit, with simulations and experiments demonstrating a sensitivity exceeding 1.4 × 10(3) nm per refractive index unit. Simulations indicate a detection limit of ~2 × 10(-6) refractive index units is achievable. We also numerically investigate the performance for refractive index changes localized at the surface of the holes, a case of particular importance for biosensing.

  15. Figure of Merit Enhancement of a Surface Plasmon Resonance Sensor Using a Low-Refractive-Index Porous Silica Film

    PubMed Central

    Meng, Qing-Qing; Zhao, Xin; Lin, Cheng-You; Chen, Shu-Jing; Ding, Ying-Chun; Chen, Zhao-Yang

    2017-01-01

    In this paper; the surface plasmon resonance (SPR) sensor with a porous silica film was studied. The effect of the thickness and porosity of the porous silica film on the performance of the sensor was analyzed. The results indicated that the figure of merit (FOM) of an SPR sensor can be enhanced by using a porous silica film with a low-refractive-index. Particularly; the FOM of an SPR sensor with 40 nm thick 90% porosity porous silica film; whose refractive index is 1.04 was improved by 311% when compared with that of a traditional SPR sensor. Furthermore; it was found that the decrease in the refractive index or the increase in the thickness of the low-refractive-index porous silica film can enlarge the FOM enhancement. It is believed that the proposed SPR sensor with a low-refractive-index porous silica film will be helpful for high-performance SPR sensors development. PMID:28796155

  16. Figure of Merit Enhancement of a Surface Plasmon Resonance Sensor Using a Low-Refractive-Index Porous Silica Film.

    PubMed

    Meng, Qing-Qing; Zhao, Xin; Lin, Cheng-You; Chen, Shu-Jing; Ding, Ying-Chun; Chen, Zhao-Yang

    2017-08-10

    In this paper; the surface plasmon resonance (SPR) sensor with a porous silica film was studied. The effect of the thickness and porosity of the porous silica film on the performance of the sensor was analyzed. The results indicated that the figure of merit (FOM) of an SPR sensor can be enhanced by using a porous silica film with a low-refractive-index. Particularly; the FOM of an SPR sensor with 40 nm thick 90% porosity porous silica film; whose refractive index is 1.04 was improved by 311% when compared with that of a traditional SPR sensor. Furthermore; it was found that the decrease in the refractive index or the increase in the thickness of the low-refractive-index porous silica film can enlarge the FOM enhancement. It is believed that the proposed SPR sensor with a low-refractive-index porous silica film will be helpful for high-performance SPR sensors development.

  17. Tunable Liquid Gradient Refractive Index (L-GRIN) lens with two degrees of freedom.

    PubMed

    Mao, Xiaole; Lin, Sz-Chin Steven; Lapsley, Michael Ian; Shi, Jinjie; Juluri, Bala Krishna; Huang, Tony Jun

    2009-07-21

    We report a tunable optofluidic microlens configuration named the Liquid Gradient Refractive Index (L-GRIN) lens for focusing light within a microfluidic device. The focusing of light was achieved through the gradient refractive index (GRIN) within the liquid medium, rather than via curved refractive lens surfaces. The diffusion of solute (CaCl(2)) between side-by-side co-injected microfluidic laminar flows was utilized to establish a hyperbolic secant (HS) refractive index profile to focus light. Tailoring the refractive index profile by adjusting the flow conditions enables not only tuning of the focal distance (translation mode), but also shifting of the output light direction (swing mode), a second degree of freedom that to our knowledge has yet to be accomplished for in-plane tunable microlenses. Advantages of the L-GRIN lens also include a low fluid consumption rate, competitive focusing performance, and high compatibility with existing microfluidic devices. This work provides a new strategy for developing integrative tunable microlenses for a variety of lab-on-a-chip applications.

  18. A pitfall in shallow shear-wave refraction surveying

    USGS Publications Warehouse

    Xia, J.; Miller, R.D.; Park, C.B.; Wightman, E.; Nigbor, R.

    2002-01-01

    The shallow shear-wave refraction method works successfully in an area with a series of horizontal layers. However, complex near-surface geology may not fit into the assumption of a series of horizontal layers. That a plane SH-wave undergoes wave-type conversion along an interface in an area of nonhorizontal layers is theoretically inevitable. One real example shows that the shallow shear-wave refraction method provides velocities of a converted wave rather than an SH- wave. Moreover, it is impossible to identify the converted wave by refraction data itself. As most geophysical engineering firms have limited resources, an additional P-wave refraction survey is necessary to verify if velocities calculated from a shear-wave refraction survey are velocities of converted waves. The alternative at this time may be the surface wave method, which can provide reliable S-wave velocities, even in an area of velocity inversion (a higher velocity layer underlain by a lower velocity layer). ?? 2002 Elsevier Science B.V. All rights reserved.

  19. Trends in refractive surgery at an academic center: 2007-2009.

    PubMed

    Kuo, Irene C

    2011-05-14

    The United States officially entered a recession in December 2007, and it officially exited the recession in December 2009, according to the National Bureau of Economic Research. Since the economy may affect not only the volume of excimer laser refractive surgery, but also the clinical characteristics of patients undergoing surgery, our goal was to compare the characteristics of patients completing excimer laser refractive surgery and the types of procedures performed in the summer quarter in 2007 and the same quarter in 2009 at an academic center. A secondary goal was to determine whether the volume of astigmatism- or presbyopia-correcting intraocular lenses (IOLs) has concurrently changed because like laser refractive surgery, these "premium" IOLs involve out-of-pocket costs for patients. Retrospective case series. Medical records were reviewed for all patients completing surgery at the Wilmer Laser Vision Center in the summer quarter of 2007 and the summer quarter of 2009. Outcome measures were the proportions of treated refractive errors, the proportion of photorefractive keratectomy (PRK) vs. laser-assisted in-situ keratomileusis (LASIK), and the mean age of patients in each quarter. Chi-square test was used to compare the proportions of treated refractive errors and the proportions of procedures; two-tailed t-test to compare the mean age of patients; and two-tailed z-test to compare proportions of grouped refractive errors in 2007 vs. 2009; alpha = 0.05 for all tests. Refractive errors were grouped by the spherical equivalent of the manifest refraction and were considered "low myopia" for 6 diopters (D) of myopia or less, "high myopia" for more than 6 D, and "hyperopia" for any hyperopia. Billing data were reviewed to obtain the volume of premium IOLs. Volume of laser refractive procedures decreased by at least 30%. The distribution of proportions of treated refractive errors did not change (p = 0.10). The proportion of high myopes, however, decreased (p = 0.05). The proportions of types of procedure changed, with an increase in the proportion of PRK between 2007 and 2009 (p = 0.02). The mean age of patients did not change [42.4 ± 14.4 (standard deviation) years in 2007 vs. 39.6 ± 14.5 years in 2009; p = 0.4]. Astigmatism-correcting IOL and presbyopia-correcting IOL volumes increased 15-fold and three-fold, respectively, between 2007 and 2009. Volume of excimer laser refractive surgery decreased by at least 30% between 2007 and 2009. No significant change in mean age or in the distribution of refractive error was seen, although the proportion of high myopes decreased between summer quarters of 2007 and 2009. PRK gained as a proportion of total cases. Premium IOL volume increased, but still comprised a very small proportion of total IOL volume.

  20. Trends in refractive surgery at an academic center: 2007-2009

    PubMed Central

    2011-01-01

    Background The United States officially entered a recession in December 2007, and it officially exited the recession in December 2009, according to the National Bureau of Economic Research. Since the economy may affect not only the volume of excimer laser refractive surgery, but also the clinical characteristics of patients undergoing surgery, our goal was to compare the characteristics of patients completing excimer laser refractive surgery and the types of procedures performed in the summer quarter in 2007 and the same quarter in 2009 at an academic center. A secondary goal was to determine whether the volume of astigmatism- or presbyopia-correcting intraocular lenses (IOLs) has concurrently changed because like laser refractive surgery, these "premium" IOLs involve out-of-pocket costs for patients. Methods Retrospective case series. Medical records were reviewed for all patients completing surgery at the Wilmer Laser Vision Center in the summer quarter of 2007 and the summer quarter of 2009. Outcome measures were the proportions of treated refractive errors, the proportion of photorefractive keratectomy (PRK) vs. laser-assisted in-situ keratomileusis (LASIK), and the mean age of patients in each quarter. Chi-square test was used to compare the proportions of treated refractive errors and the proportions of procedures; two-tailed t-test to compare the mean age of patients; and two-tailed z-test to compare proportions of grouped refractive errors in 2007 vs. 2009; alpha = 0.05 for all tests. Refractive errors were grouped by the spherical equivalent of the manifest refraction and were considered "low myopia" for 6 diopters (D) of myopia or less, "high myopia" for more than 6 D, and "hyperopia" for any hyperopia. Billing data were reviewed to obtain the volume of premium IOLs. Results Volume of laser refractive procedures decreased by at least 30%. The distribution of proportions of treated refractive errors did not change (p = 0.10). The proportion of high myopes, however, decreased (p = 0.05). The proportions of types of procedure changed, with an increase in the proportion of PRK between 2007 and 2009 (p = 0.02). The mean age of patients did not change [42.4 ± 14.4 (standard deviation) years in 2007 vs. 39.6 ± 14.5 years in 2009; p = 0.4]. Astigmatism-correcting IOL and presbyopia-correcting IOL volumes increased 15-fold and three-fold, respectively, between 2007 and 2009. Conclusions Volume of excimer laser refractive surgery decreased by at least 30% between 2007 and 2009. No significant change in mean age or in the distribution of refractive error was seen, although the proportion of high myopes decreased between summer quarters of 2007 and 2009. PRK gained as a proportion of total cases. Premium IOL volume increased, but still comprised a very small proportion of total IOL volume. PMID:21569564

  1. Seven-year incidence of uncorrected refractive error among an elderly Chinese population in Shihpai, Taiwan: The Shihpai Eye Study

    PubMed Central

    Kuang, T-M; Tsai, S-Y; Liu, C J-L; Ko, Y-C; Lee, S-M; Chou, P

    2016-01-01

    Purpose To report the 7-year incidence of uncorrected refractive error in a metropolitan Chinese elderly population. Methods The Shihpai Eye Study 2006 included 460/824 (55.8%) subjects (age range 72–94 years old) of 1361 participants in the 1999 baseline survey for a follow-up eye examination. Visual acuity was assessed using a Snellen chart, uncorrected refractive error was defined as presenting visual acuity (naked eye if without spectacles and with distance spectacles if worn) in the better eye of <6/12 that improved to no impairment (≥6/12) after refractive correction. Results The 7-year incidence of uncorrected refractive error was 10.5% (95% confidence interval (CI): 7.6–13.4%). 92.7% of participants with uncorrection and 77.8% with undercorrection were able to improve at least two lines of visual acuity by refractive correction. In multivariate analysis controlling for covariates, uncorrected refractive error was significantly related to myopia (relative risk (RR): 3.15; 95% CI: 1.31–7.58) and living alone (RR: 2.94; 95% CI 1.14–7.53), whereas distance spectacles worn during examination was protective (RR: 0.35; 95% CI: 0.14–0.88). Conclusion Our study indicated that the incidence of uncorrected refractive error was high (10.5%) in this elderly Chinese population. Living alone and myopia are predisposing factors, whereas wearing distance spectacles at examination is protective. PMID:26795416

  2. The Complex Refractive Index of Volcanic Ash Aerosol Retrieved From Spectral Mass Extinction

    NASA Astrophysics Data System (ADS)

    Reed, Benjamin E.; Peters, Daniel M.; McPheat, Robert; Grainger, R. G.

    2018-01-01

    The complex refractive indices of eight volcanic ash samples, chosen to have a representative range of SiO2 contents, were retrieved from simultaneous measurements of their spectral mass extinction coefficient and size distribution. The mass extinction coefficients, at 0.33-19 μm, were measured using two optical systems: a Fourier transform spectrometer in the infrared and two diffraction grating spectrometers covering visible and ultraviolet wavelengths. The particle size distribution was measured using a scanning mobility particle sizer and an optical particle counter; values for the effective radius of ash particles measured in this study varied from 0.574 to 1.16 μm. Verification retrievals on high-purity silica aerosol demonstrated that the Rayleigh continuous distribution of ellipsoids (CDEs) scattering model significantly outperformed Mie theory in retrieving the complex refractive index, when compared to literature values. Assuming the silica particles provided a good analogue of volcanic ash, the CDE scattering model was applied to retrieve the complex refractive index of the eight ash samples. The Lorentz formulation of the complex refractive index was used within the retrievals as a convenient way to ensure consistency with the Kramers-Kronig relation. The short-wavelength limit of the electric susceptibility was constrained by using independently measured reference values of the complex refractive index of the ash samples at a visible wavelength. The retrieved values of the complex refractive indices of the ash samples showed considerable variation, highlighting the importance of using accurate refractive index data in ash cloud radiative transfer models.

  3. High Dynamic Range (Δn) Two-Stage Photopolymers via Enhanced Solubility of a High Refractive Index Acrylate Writing Monomer.

    PubMed

    Alim, Marvin D; Glugla, David J; Mavila, Sudheendran; Wang, Chen; Nystrom, Philip D; Sullivan, Amy C; McLeod, Robert R; Bowman, Christopher N

    2018-01-10

    Holographic photopolymers capable of high refractive index modulation (Δn) on the order of 10 -2 are integral for the fabrication of functional holographic optical elements that are useful in a myriad of optical applications. In particular, to address the deficiency of suitable high refractive index writing monomers for use in two-stage holographic formulations, here we report a novel high refractive index writing monomer, 1,3-bis(phenylthio)-2-propyl acrylate (BPTPA), simultaneously possessing enhanced solubility in a low refractive index (n = 1.47) urethane matrix. When examined in comparison to a widely used high refractive index monomer, 2,4,6-tribromophenyl acrylate, BPTPA exhibited superior solubility in a stage 1 urethane matrix of approximately 50% with a 20% higher refractive index increase per unit amount of the writing monomer for stage 2 polymerizations. Formulations with 60 wt % loading of BPTPA exhibit a peak-to-mean holographic Δn ≈ 0.029 without obvious deficiencies in transparency, color, or scatter. To the best of our knowledge, this value is the highest reported in the peer-reviewed literature for a transmission hologram. The capabilities and versatility of BPTPA-based formulations are demonstrated at varying length scales via demonstrative refractive index gradient structure examples including direct laser write, projection mask lithography of a 1″ diameter Fresnel lens, and ∼100% diffraction efficiency volume transmission holograms with a 1 μm fringe spacing in 11 μm thick samples.

  4. Global magnitude of visual impairment caused by uncorrected refractive errors in 2004

    PubMed Central

    Pascolini, Donatella; Mariotti, Silvio P; Pokharel, Gopal P

    2008-01-01

    Abstract Estimates of the prevalence of visual impairment caused by uncorrected refractive errors in 2004 have been determined at regional and global levels for people aged 5 years and over from recent published and unpublished surveys. The estimates were based on the prevalence of visual acuity of less than 6/18 in the better eye with the currently available refractive correction that could be improved to equal to or better than 6/18 by refraction or pinhole. A total of 153 million people (range of uncertainty: 123 million to 184 million) are estimated to be visually impaired from uncorrected refractive errors, of whom eight million are blind. This cause of visual impairment has been overlooked in previous estimates that were based on best-corrected vision. Combined with the 161 million people visually impaired estimated in 2002 according to best-corrected vision, 314 million people are visually impaired from all causes: uncorrected refractive errors become the main cause of low vision and the second cause of blindness. Uncorrected refractive errors can hamper performance at school, reduce employability and productivity, and generally impair quality of life. Yet the correction of refractive errors with appropriate spectacles is among the most cost-effective interventions in eye health care. The results presented in this paper help to unearth a formerly hidden problem of public health dimensions and promote policy development and implementation, programmatic decision-making and corrective interventions, as well as stimulate research. PMID:18235892

  5. Prevalence of amblyopia and patterns of refractive error in the amblyopic children of a tertiary eye care center of Nepal.

    PubMed

    Sapkota, K; Pirouzian, A; Matta, N S

    2013-01-01

    Refractive error is a common cause of amblyopia. To determine prevalence of amblyopia and the pattern and the types of refractive error in children with amblyopia in a tertiary eye hospital of Nepal. A retrospective chart review of children diagnosed with amblyopia in the Nepal Eye Hospital (NEH) from July 2006 to June 2011 was conducted. Children of age 13+ or who had any ocular pathology were excluded. Cycloplegic refraction and an ophthalmological examination was performed for all children. The pattern of refractive error and the association between types of refractive error and types of amblyopia were determined. Amblyopia was found in 0.7 % (440) of 62,633 children examined in NEH during this period. All the amblyopic eyes of the subjects had refractive error. Fifty-six percent (248) of the patients were male and the mean age was 7.74 ± 2.97 years. Anisometropia was the most common cause of amblyopia (p less than 0.001). One third (29 %) of the subjects had bilateral amblyopia due to high ametropia. Forty percent of eyes had severe amblyopia with visual acuity of 20/120 or worse. About twothirds (59.2 %) of the eyes had astigmatism. The prevalence of amblyopia in the Nepal Eye Hospital is 0.7%. Anisometropia is the most common cause of amblyopia. Astigmatism is the most common types of refractive error in amblyopic eyes. © NEPjOPH.

  6. Refraction in Exoplanet Transit Observations

    NASA Astrophysics Data System (ADS)

    Dalba, Paul

    2018-01-01

    Before an exoplanet transit, atmospheric refraction bends light into the line of sight of an observer. The refracted light forms a stellar mirage---a distorted secondary image of the host star---that causes flux increases before transit ingress and after transit egress. The extent of this flux increase provides clues as to the composition and structure of the exoplanetary atmosphere. Here, I model the stellar mirages produced by a comprehensive set of stellar, orbital, planetary, and atmospheric parameters. Refracted light offers unprecedented atmospheric characterization opportunities for cold, long-period gas giant exoplanets. At visible wavelengths, opacity from Rayleigh scattering presents a substantial challenge to detecting stellar mirages for most exoplanets with orbital distances less than 6 AU. Based on physical parameters, I derive a criterion that determines if refracted light will significantly influence observations of a specific exoplanetary system with application to the high-precision Kepler data set. I also investigate the potential for refracted light to identify non-transiting exoplanets and serve as a novel means of out-of-transit atmospheric characterization. The atmospheric lensing events produced by non-transiting exoplanets are more detectable than the corresponding flux increases for transiting exoplanets. Compared to visible light observations, those at red to near-infrared wavelengths are more likely to detect refracted light in an exoplanet atmosphere. With upcoming exoplanet discovery and characterization missions in mind, I consider science cases that are uniquely enabled by photometric and spectroscopic observations of refracted light in exoplanetary systems.

  7. The relationship between refractive and biometric changes during Edinger–Westphal stimulated accommodation in rhesus monkeys

    PubMed Central

    Vilupuru, Abhiram S.; Glasser, Adrian

    2010-01-01

    Experiments were undertaken to understand the relationship between dynamic accommodative refractive and biometric (lens thickness (LT), anterior chamber depth (ACD) and anterior segment length (ASL=ACD+LT)) changes during Edinger–Westphal stimulated accommodation in rhesus monkeys. Experiments were conducted on three rhesus monkeys (aged 11·5, 4·75 and 4·75 years) which had undergone prior, bilateral, complete iridectomies and implantation of a stimulating electrode in the Edinger–Westphal (EW) nucleus. Accommodative refractive responses were first measured dynamically with video-based infrared photorefraction and then ocular biometric responses were measured dynamically with continuous ultrasound biometry (CUB) during EW stimulation. The same stimulus amplitudes were used for the refractive and biometric measurements to allow them to be compared. Main sequence relationships (ratio of peak velocity to amplitude) were calculated. Dynamic accommodative refractive changes are linearly correlated with the biometric changes and accommodative biometric changes in ACD, ASL and LT show systematic linear correlations with increasing accommodative amplitudes. The relationships are relatively similar for the eyes of the different monkeys. Dynamic analysis showed that main sequence relationships for both biometry and refraction are linear. Although accommodative refractive changes in the eye occur primarily due to changes in lens surface curvature, the refractive changes are well correlated with A-scan measured accommodative biometric changes. Accommodative changes in ACD, LT and ASL are all well correlated over the full extent of the accommodative response. PMID:15721617

  8. Vacuum birefringence in strong magnetic fields: (II) Complex refractive index from the lowest Landau level

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hattori, Koichi, E-mail: khattori@yonsei.ac.kr; Itakura, Kazunori, E-mail: kazunori.itakura@kek.jp; Department of Particle and Nuclear Studies, Graduate University for Advanced Studies

    2013-07-15

    We compute the refractive indices of a photon propagating in strong magnetic fields on the basis of the analytic representation of the vacuum polarization tensor obtained in our previous paper. When the external magnetic field is strong enough for the fermion one-loop diagram of the polarization tensor to be approximated by the lowest Landau level, the propagating mode in parallel to the magnetic field is subject to modification: The refractive index deviates from unity and can be very large, and when the photon energy is large enough, the refractive index acquires an imaginary part indicating decay of a photon intomore » a fermion–antifermion pair. We study dependences of the refractive index on the propagating angle and the magnetic-field strength. It is also emphasized that a self-consistent treatment of the equation which defines the refractive index is indispensable for accurate description of the refractive index. This self-consistent treatment physically corresponds to consistently including the effects of back reactions of the distorted Dirac sea in response to the incident photon. -- Highlights: •Vacuum birefringence and photon decay are described by the complex refractive index. •Resummed photon vacuum polarization tensor in the lowest Landau level is used. •Back reactions from the distorted Dirac sea are self-consistently taken into account. •Self-consistent treatment drastically changes structure in photon energy dependence. •Dependences on photon propagation angle and magnetic-field strength are presented.« less

  9. [Correction of refractive errors in patients with strabismus. Part I. Clinical problems associated with refraction, accommodation and convergence].

    PubMed

    Tokarz-Sawińska, Ewa

    2012-01-01

    In Part I the problems associated with refraction, accommodation and convergence and their role in proper eye position/visual alignment of the eyes as well as convergent, divergent and vertical alignment of the eyes have been described.

  10. Gradient Refractive Index Lenses.

    ERIC Educational Resources Information Center

    Morton, N.

    1984-01-01

    Describes the nature of gradient refractive index (GRIN) lenses, focusing on refraction in these materials, focal length of a thin Wood lens, and on manufacturing of such lenses. Indicates that GRIN lenses of small cross section are in limited production with applications suggested for optical communication and photocopying fields. (JN)

  11. Change in refraction after lens-sparing vitrectomy for rhegmatogenous retinal detachment and epiretinal membrane.

    PubMed

    Iwase, Takeshi; Yamamoto, Kentaro; Yanagida, Kosei; Kobayashi, Misato; Ra, Eimei; Murotani, Kenta; Terasaki, Hiroko

    2016-08-01

    The aim of this study was to compare changes in refraction following lens-sparing vitrectomy between patients with rhegmatogenous retinal detachment (RRD) and epiretinal membrane (ERM) and to investigate factors associated with the change in refraction.We reviewed medical records of 49 eyes of 49 patients with RRD (53.6 ± 7.8 years, mean ± standard deviation) and 24 eyes of 24 patients with ERM (50.9 ± 15.7 years) who underwent lens-sparing vitrectomy. Spherical equivalent refractive power was evaluated before and up to 18 months after surgery. The relationship between the change in refraction and several parameters was evaluated.A significant progressive myopic shift in refractive power was observed after vitrectomy in operated RRD and ERM eyes (P < 0.001, P = 0.016, respectively), with no significant difference in fellow eyes. The refraction values observed at ≥3 and ≥12 months following vitrectomy were significantly different as compared with those observed at baseline in the RRD group (P < 0.001) and the ERM group (P < 0.05), respectively. The change in refraction between the RRD and ERM groups was significant (P = 0.030). The multiple linear regression analysis showed that only age was significantly correlated with the change in refraction in RRD (P = 0.018) and ERM (P < 0.001) groups. The change in refraction was significantly and positively correlated with age in RRD (r = -0.461, P = 0.001) and ERM (r = -0.687, P < 0.001) groups. Following lens-sparing vitrectomy, cataract surgery was performed on 30 eyes after 0.89 ± 0.26 years in the RRD group and on 10 eyes after 1.11 ± 0.14 years in the ERM group; there was a significant difference in time to cataract surgery between the groups (P = 0.007). Kaplan-Meier survival analysis demonstrated that there was a significant difference in the rate of cataract surgeries between the RRD and ERM groups (P = 0.022).Following lens-sparing vitrectomy for RRD and ERM, a progressive myopic shift in refraction owing to nuclear sclerosis was observed. Core vitrectomy itself would cause a myopic shift of refraction. The only risk factor associated with cataract progression following lens-sparing vitrectomy is age for both types of patients.

  12. Change in refraction after lens-sparing vitrectomy for rhegmatogenous retinal detachment and epiretinal membrane

    PubMed Central

    Iwase, Takeshi; Yamamoto, Kentaro; Yanagida, Kosei; Kobayashi, Misato; Ra, Eimei; Murotani, Kenta; Terasaki, Hiroko

    2016-01-01

    Abstract The aim of this study was to compare changes in refraction following lens-sparing vitrectomy between patients with rhegmatogenous retinal detachment (RRD) and epiretinal membrane (ERM) and to investigate factors associated with the change in refraction. We reviewed medical records of 49 eyes of 49 patients with RRD (53.6 ± 7.8 years, mean ± standard deviation) and 24 eyes of 24 patients with ERM (50.9 ± 15.7 years) who underwent lens-sparing vitrectomy. Spherical equivalent refractive power was evaluated before and up to 18 months after surgery. The relationship between the change in refraction and several parameters was evaluated. A significant progressive myopic shift in refractive power was observed after vitrectomy in operated RRD and ERM eyes (P < 0.001, P = 0.016, respectively), with no significant difference in fellow eyes. The refraction values observed at ≥3 and ≥12 months following vitrectomy were significantly different as compared with those observed at baseline in the RRD group (P < 0.001) and the ERM group (P < 0.05), respectively. The change in refraction between the RRD and ERM groups was significant (P = 0.030). The multiple linear regression analysis showed that only age was significantly correlated with the change in refraction in RRD (P = 0.018) and ERM (P < 0.001) groups. The change in refraction was significantly and positively correlated with age in RRD (r = −0.461, P = 0.001) and ERM (r = −0.687, P < 0.001) groups. Following lens-sparing vitrectomy, cataract surgery was performed on 30 eyes after 0.89 ± 0.26 years in the RRD group and on 10 eyes after 1.11 ± 0.14 years in the ERM group; there was a significant difference in time to cataract surgery between the groups (P = 0.007). Kaplan–Meier survival analysis demonstrated that there was a significant difference in the rate of cataract surgeries between the RRD and ERM groups (P = 0.022). Following lens-sparing vitrectomy for RRD and ERM, a progressive myopic shift in refraction owing to nuclear sclerosis was observed. Core vitrectomy itself would cause a myopic shift of refraction. The only risk factor associated with cataract progression following lens-sparing vitrectomy is age for both types of patients. PMID:27512843

  13. Measuring Variable Refractive Indices Using Digital Photos

    ERIC Educational Resources Information Center

    Lombardi, S.; Monroy, G.; Testa, I.; Sassi, E.

    2010-01-01

    A new procedure for performing quantitative measurements in teaching optics is presented. Application of the procedure to accurately measure the rate of change of the variable refractive index of a water-denatured alcohol mixture is described. The procedure can also be usefully exploited for measuring the constant refractive index of distilled…

  14. Modification of the DSN radio frequency angular tropospheric refraction model

    NASA Technical Reports Server (NTRS)

    Berman, A. L.

    1977-01-01

    The previously derived DSN Radio Frequency Angular Tropospheric Refraction Model contained an assumption which was subsequently seen to be at a variance with the theoretical basis of angular refraction. The modification necessary to correct the model is minor in that the value of a constant is changed.

  15. Temperature-Dependent Refractive Index of Cleartran® ZnS to Cryogenic Temperatures

    NASA Technical Reports Server (NTRS)

    Leviton, Doug; Frey, Brad

    2013-01-01

    First, let's talk about the CHARMS facility at NASA's Goddard Space Flight Center: Cryogenic, High-Accuracy Refraction Measuring System (CHARMS); design features for highest accuracy and precision; technologies we rely on; data products and examples; optical materials for which we've measured cryogenic refractive index.

  16. Negative Refraction in a Uniaxial Absorbent Dielectric Material

    ERIC Educational Resources Information Center

    Jen, Yi-Jun; Lakhtakia, Akhlesh; Yu, Ching-Wei; Lin, Chin-Te

    2009-01-01

    Refraction of light from an isotropic dielectric medium to an anisotropic dielectric material is a complicated phenomenon that can have several different characteristics not usually discussed in electromagnetics textbooks for undergraduate students. With a simple problem wherein the refracting material is uniaxial with its optic axis normal to the…

  17. Measurement of Refractive Index Gradients by Deflection of a Laser Beam

    ERIC Educational Resources Information Center

    Barnard, A. J.; Ahlborn, B.

    1975-01-01

    In this simple experiment for an undergraduate laboratory a laser beam is passed through the mixing zone of two liquids with different refractive indices. The spatial variation of the refractive index, at different times during the mixing, can be determined from the observed deflection of the beam. (Author)

  18. Numerical Simulations of Shock Wave Refraction at Inclined Gas Contact Discontinuity

    ERIC Educational Resources Information Center

    Bulat, Pavel V.; Volkov, Konstantin N.

    2016-01-01

    When a shock wave interacts with a contact discontinuity, there may appear a reflected rarefaction wave, a deflected contact discontinuity and a refracted supersonic shock. The numerical simulation of shock wave refraction at a plane contact discontinuity separating gases with different densities is performed. Euler equations describing inviscid…

  19. Helping Secondary School Students Develop a Conceptual Understanding of Refraction

    ERIC Educational Resources Information Center

    Ashmann, Scott; Anderson, Charles W.; Boeckman, Heather

    2016-01-01

    Using real-world examples, ray diagrams, and a cognitive apprenticeship cycle, this paper focuses on developing students' conceptual (not mathematical) understanding of refraction. Refraction can be a difficult concept for students to comprehend if they do not have well-designed opportunities to practice explaining situations where reflection and…

  20. Surface refractivity measurements at NASA spacecraft tracking sites

    NASA Technical Reports Server (NTRS)

    Schmid, P. E.

    1972-01-01

    High-accuracy spacecraft tracking requires tropospheric modeling which is generally scaled by either estimated or measured values of surface refractivity. This report summarizes the results of a worldwide surface-refractivity test conducted in 1968 in support of the Apollo program. The results are directly applicable to all NASA radio-tracking systems.

  1. Construction of Lines of Constant Density and Constant Refractive Index for Ternary Liquid Mixtures.

    ERIC Educational Resources Information Center

    Tasic, Aleksandar Z.; Djordjevic, Bojan D.

    1983-01-01

    Demonstrates construction of density constant and refractive index constant lines in triangular coordinate system on basis of systematic experimental determinations of density and refractive index for both homogeneous (single-phase) ternary liquid mixtures (of known composition) and the corresponding binary compositions. Background information,…

  2. Infrasonic ray tracing applied to mesoscale atmospheric structures: refraction by hurricanes.

    PubMed

    Bedard, Alfred J; Jones, R Michael

    2013-11-01

    A ray-tracing program is used to estimate the refraction of infrasound by the temperature structure of the atmosphere and by hurricanes represented by a Rankine-combined vortex wind plus a temperature perturbation. Refraction by the hurricane winds is significant, giving rise to regions of focusing, defocusing, and virtual sources. The refraction of infrasound by the temperature anomaly associated with a hurricane is small, probably no larger than that from uncertainties in the wind field. The results are pertinent to interpreting ocean wave generated infrasound in the vicinities of tropical cyclones.

  3. Out-of-plane reflection and refraction of light by anisotropic optical antenna metasurfaces with phase discontinuities.

    PubMed

    Aieta, Francesco; Genevet, Patrice; Yu, Nanfang; Kats, Mikhail A; Gaburro, Zeno; Capasso, Federico

    2012-03-14

    Experiments on ultrathin anisotropic arrays of subwavelength optical antennas display out-of-plane refraction. A powerful three-dimensional (3D) extension of the recently demonstrated generalized laws of refraction and reflection shows that the interface imparts a tangential wavevector to the incident light leading to anomalous beams, which in general are noncoplanar with the incident beam. The refracted beam direction can be controlled by varying the angle between the plane of incidence and the antenna array. © 2012 American Chemical Society

  4. Negative refraction with low absorption using Raman transitions with magnetoelectric coupling

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sikes, D. E.; Yavuz, D. D.

    2010-07-15

    We suggest a scheme for obtaining negative refraction that does not require the simultaneous presence of an electric-dipole and a magnetic-dipole transition near the same transition frequency. The key idea of the scheme is to obtain a strong electric response by using far-off-resonant Raman transitions. We propose to use a pair of electric-dipole Raman transitions and utilize magneto-electric cross coupling to achieve a negative index of refraction without requiring negative permeability. The interference of the two Raman transitions allows tunable negative refraction with low absorption.

  5. Direct measurements of nonlinear absorption and refraction in solutions of phthalocyanines

    NASA Technical Reports Server (NTRS)

    Wei, T. H.; Hagan, D. J.; Sence, M. J.; Van Stryland, E. W.; Perry, J. W.; Coulter, D. R.

    1992-01-01

    Direct measurements are reported of the excited singlet-state absorption cross section and the associated nonlinear refractive cross section using picosecond pulses at 532 nm in solutions of phthalocyanine and naphthalocyanine dyes. By monitoring the transmittance and far-field spatial beam distortion for different pulsewidths in the picosecond regime, it is shown that both the nonlinear absorption and refraction are fluence (energy-per-unit-area) rather than irradiance dependent. Thus, excited-state absorption is the dominant nonlinear absorption process, and the observed nonlinear refraction is also due to real population excitation.

  6. Slot-waveguide biochemical sensor.

    PubMed

    Barrios, Carlos A; Gylfason, Kristinn B; Sánchez, Benito; Griol, Amadeu; Sohlström, H; Holgado, M; Casquel, R

    2007-11-01

    We report an experimental demonstration of an integrated biochemical sensor based on a slot-waveguide microring resonator. The microresonator is fabricated on a Si3N4-SiO2 platform and operates at a wavelength of 1.3 microm. The transmission spectrum of the sensor is measured with different ambient refractive indices ranging from n=1.33 to 1.42. A linear shift of the resonant wavelength with increasing ambient refractive index of 212 nm/refractive index units (RIU) is observed. The sensor detects a minimal refractive index variation of 2x10(-4) RIU.

  7. Polymer X-ray refractive nano-lenses fabricated by additive technology.

    PubMed

    Petrov, A K; Bessonov, V O; Abrashitova, K A; Kokareva, N G; Safronov, K R; Barannikov, A A; Ershov, P A; Klimova, N B; Lyatun, I I; Yunkin, V A; Polikarpov, M; Snigireva, I; Fedyanin, A A; Snigirev, A

    2017-06-26

    The present work demonstrates the potential applicability of additive manufacturing to X-Ray refractive nano-lenses. A compound refractive lens with a radius of 5 µm was produced by the two-photon polymerization induced lithography. It was successfully tested at the X-ray microfocus laboratory source and a focal spot of 5 μm was measured. An amorphous nature of polymer material combined with the potential of additive technologies may result in a significantly enhanced focusing performance compared to the best examples of modern X-ray compound refractive lenses.

  8. Waveguide-based optical chemical sensor

    DOEpatents

    Grace, Karen M [Ranchos de Taos, NM; Swanson, Basil I [Los Alamos, NM; Honkanen, Seppo [Tucson, AZ

    2007-03-13

    The invention provides an apparatus and method for highly selective and sensitive chemical sensing. Two modes of laser light are transmitted through a waveguide, refracted by a thin film host reagent coating on the waveguide, and analyzed in a phase sensitive detector for changes in effective refractive index. Sensor specificity is based on the particular species selective thin films of host reagents which are attached to the surface of the planar optical waveguide. The thin film of host reagents refracts laser light at different refractive indices according to what species are forming inclusion complexes with the host reagents.

  9. Refractive index of dark-adapted bacteriorhodopsin and tris(hydroxymethyl)aminomethane buffer between 390 and 880 nm.

    PubMed

    Heiner, Zsuzsanna; Osvay, Károly

    2009-08-10

    The refractivity of wild-type bacteriorhodopsin (bR(WT)) suspended in tris(hydroxymethyl)aminomethane (TRIS) buffer has been measured in the spectral range of 390-840 nm by the method of angle of minimal deviation with the use of a hollow glass prism. The refractive indices of pure bR(WT) as well as of TRIS buffer have been determined from the concentration dependent refraction values. Sellmeier-type dispersion equations have been fitted for both the TRIS buffer and pure bR(WT).

  10. Enhancing intensity and refractive index sensing capability with infrared plasmonic perfect absorbers.

    PubMed

    Cheng, Fei; Yang, Xiaodong; Gao, Jie

    2014-06-01

    An infrared refractive index sensor based on plasmonic perfect absorbers for glucose concentration sensing is experimentally demonstrated. Utilizing substantial absorption contrast between a perfect absorber (∼98% at normal incidence) and a non-perfect absorber upon the refractive index change, a maximum value of figure of merit (FOM*) about 55 and a bulk wavelength sensitivity about 590  nm/RIU are achieved. The demonstrated sensing platform provides great potential in improving the performance of plasmonic refractive index sensors and developing future surface enhanced infrared spectroscopy.

  11. REVIEWS OF TOPICAL PROBLEMS: Recent advances in X-ray refractive optics

    NASA Astrophysics Data System (ADS)

    Aristov, V. V.; Shabel'nikov, L. G.

    2008-01-01

    X-ray refractive optics has made rapid strides to a large degree due to the work of Russian scientists, and has now become one of the most rapidly advancing areas in modern physical optics. This review outlines the results of investigation of refractive devices and analysis of their properties. The conception of planar lenses made of silicon and other materials is set forth. We discuss the applications of refractive lenses to the transformation of X-ray images, photonic crystal research, and the development of focusing devices in high-energy X-ray telescopes.

  12. Reflectivity of a disordered monolayer estimated by graded refractive index and scattering models.

    PubMed

    Diamant, Ruth; Garcí-Valenzuela, Augusto; Fernández-Guasti, Manuel

    2012-09-01

    Reflectivity of a random monolayer, consisting of transparent spherical particles, is estimated using a graded refractive index model, an effective medium approach, and two scattering models. Two cases, a self-standing film and one with a substrate, are considered. Neither the surrounding medium nor the substrate are absorbing materials. Results at normal incidence, with different particle sizes, covering ratios and refractive indexes, are compared. The purpose of this work is to find under which circumstances, for reflectivity at normal incidence, a particle monolayer behaves as a graded refractive index film.

  13. Far-field self-focusing and -defocusing radiation behaviors of the electroluminescent light sources due to negative refraction.

    PubMed

    Yin, Yu-Feng; Lin, Yen-Chen; Tsai, Tsung-Han; Shen, Yi-Chun; Huang, Jianjang

    2013-01-15

    In recent years, researchers have demonstrated negative refraction theoretically and experimentally by pumping optical power into photonic crystal (PhC) or waveguide structures. The concept of negative refraction can be used to create a perfect lens that focuses an object smaller than the wavelength. By inserting two-dimensional PhCs into the peripheral of a semiconductor light emitting structure, this study presents an electroluminescent device with negative refraction in the visible wavelength range. This approach produces polarization dependent collimation behavior in far-field radiation patterns. The modal dispersion of negative refraction results in strong group velocity modulation, and self-focusing and -defocusing behaviors are apparent from light extraction. This study further verifies experimental results by using theoretic calculations based on equifrequency contours.

  14. The Cryogenic, High-Accuracy, Refraction Measuring System (CHARMS): A New Facility for Cryogenic Infrared through Vacuum Far-Ultraviolet Refractive Index Measurements

    NASA Technical Reports Server (NTRS)

    Frey, Bradley J.; Leviton, Douglas B.

    2004-01-01

    The optical designs of future NASA infrared (IR) missions and instruments, such as the James Webb Space Telescope's (JWST) Near-Mixed Camera (NIRCam), will rely on accurate knowledge of the index of refraction of various IR optical materials at cryogenic temperatures. To meet this need, we have developed a Cryogenic, High-Accuracy Refraction Measuring System (CHARMS). In this paper we discuss the completion of the design and construction of CHARMS as well as the engineering details that constrained the final design and hardware implementation. In addition, we will present our first light, cryogenic, IR index of refraction data for LiF, BaF2, and CaF2, and compare our results to previously published data for these materials.

  15. Isaac Newton and the astronomical refraction.

    PubMed

    Lehn, Waldemar H

    2008-12-01

    In a short interval toward the end of 1694, Isaac Newton developed two mathematical models for the theory of the astronomical refraction and calculated two refraction tables, but did not publish his theory. Much effort has been expended, starting with Biot in 1836, in the attempt to identify the methods and equations that Newton used. In contrast to previous work, a closed form solution is identified for the refraction integral that reproduces the table for his first model (in which density decays linearly with elevation). The parameters of his second model, which includes the exponential variation of pressure in an isothermal atmosphere, have also been identified by reproducing his results. The implication is clear that in each case Newton had derived exactly the correct equations for the astronomical refraction; furthermore, he was the first to do so.

  16. Groove micro-structure optical fiber refractive index sensor with nanoscale gold film based on surface plasmon resonance

    NASA Astrophysics Data System (ADS)

    Zhang, Zhen; Li, Shuguang; Liu, Qiang; Feng, Xinxing; Zhang, Shuhuan; Wang, Yujun; Wu, Junjun

    2018-07-01

    A groove micro-structure optical fiber refractive index sensor with nanoscale gold film based on surface plasmon resonance (SPR) is proposed and analyzed by the finite element method (FEM). Numerical results show that the average sensitivity is 15,933 nm/refractive index unit (RIU) with the refractive index of analyte ranging from 1.40 to 1.43 and the maximum sensitivity is 28,600 nm/RIU and the resolution of the sensor is 3.50 × 10-8 RIU. The groove micro-structure optical fiber refractive index sensor do some changes on the D-shaped fiber sensor, compared with conventional D-shaped fiber sensor, it has a higher sensitivity and it is easier to produce than the traditional SPR sensor.

  17. [Refractive errors as causes of visual impairment in children from public schools of the Botucatu region - SP].

    PubMed

    Oliveira, Claudia Akemi Shiratori de; Hisatomi, Kenia Scrocaro; Leite, Cristiano Pinheiro; Schellini, Silvana Artioli; Padovani, Carlos Roberto; Padovani, Carlos Roberto Pereira

    2009-01-01

    To evaluate the refractive errors as cause of visual impairment in school children from the Botucatu region. A sectional study was conducted evaluating preschool and elementary school students, according to gender, refractive error, visual acuity and treatment. Four thousand six hundred and twenty-three (4,623) children were submitted to visual acuity evaluation and 8.1% of them were submitted to complete ocular examination. There were 63.2% hyperopic astigmatism, 15.7% myopic astigmatism, 12.5% astigmatism, 4.9% hyperopia and 3.7% myopia. Corrective lenses were prescribed for 48.7% of the evaluated children. The most frequent refractive error was hyperopic astigmatism and 50% of the children received treatment. The frequency of refractive errors was 3.9% of the studied population.

  18. Refractive index modulation in LiNbO3: MgO slab through Lamb wave

    NASA Astrophysics Data System (ADS)

    Prakash, Suraj; Sharma, Gaurav; Yadav, Gulab Chand; Singh, Vivek

    2018-05-01

    Present theoretical analysis deals with inducing refractive index contrast in Y-Z LiNbO3:MgO plate via GHz Lamb wave perturbation for photonic applications. Dispersion curves for Lamb wave in plate are plotted by employing displacement potential technique. Selecting wave parameters from dispersion curve, fundamental symmetric Lamb mode (S0) is excited in slab for 6GHz frequency. Produced displacement field by propagating S0 mode and thus developed strain is estimated to calculate refractive index modulation by applying photo-elastic relations. Modulated refractive index is of sinusoidal nature with period of modulation dependence on Lamb's wavelength. This plate having periodically modulated refractive index can be used as photonic crystal for different applications with acoustically tunable photonic band gap.

  19. Methods for prediction of refractive index in glasses for the infrared

    NASA Astrophysics Data System (ADS)

    McCloy, John S.

    2011-06-01

    It is often useful to obtain custom glasses that meet particular requirements of refractive index and dispersion for highend optical design and applications. In the case of infrared glasses, limited experimental data are available due to difficulties in processing of these glasses and also measuring refractive indices accurately. This paper proposes methods to estimate refractive index and dispersion as a function of composition for selected infrared-transmitting glasses. Methods for refractive index determination are reviewed and evaluated, including Gladstone-Dale, Wemple- DiDomenico single oscillator, Optical basicity, and Lorentz-Lorenz total polarizability. Various estimates for a set of PbO-Bi2O3-Ga2O3 (heavy metal oxide) and As-S (chalcogenide) glasses will be compared with measured values of index and dispersion.

  20. The Use of Index-Matched Beads in Optical Particle Counters

    PubMed Central

    Hu, Zhishang; Ripple, Dean C

    2014-01-01

    In this paper, we demonstrate the use of 2-pyridinemethanol (2P) aqueous solutions as a refractive index matching liquid. The high refractive index and low viscosity of 2P-water mixtures enables refractive index matching of beads that cannot be index matched with glycerol-water or sucrose-water solutions, such as silica beads that have the refractive index of bulk fused silica or of polymethylmethacrylate beads. Suspensions of beads in a nearly index-matching liquid are a useful tool to understand the response of particle counting instruments to particles of low optical contrast, such as aggregated protein particles. Data from flow imaging and light obscuration instruments are presented for bead diameters ranging from 6 µm to 69 µm, in a matrix liquid spanning the point of matched refractive index. PMID:26601049

  1. Technique for forming ITO films with a controlled refractive index

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Markov, L. K., E-mail: l.markov@mail.ioffe.ru; Smirnova, I. P.; Pavluchenko, A. S.

    2016-07-15

    A new method for fabricating transparent conducting coatings based on indium-tin oxide (ITO) with a controlled refractive index is proposed. This method implies the successive deposition of material by electron-beam evaporation and magnetron sputtering. Sputtered coatings with different densities (and, correspondingly, different refractive indices) can be obtained by varying the ratio of the mass fractions of material deposited by different methods. As an example, films with effective refractive indices of 1.2, 1.4, and 1.7 in the wavelength range of 440–460 nm are fabricated. Two-layer ITO coatings with controlled refractive indices of the layers are also formed by the proposed method.more » Thus, multilayer transparent conducting coatings with desired optical parameters can be produced.« less

  2. Simultaneous measurements of absorption spectrum and refractive index in a microfluidic system.

    PubMed

    Helseth, Lars Egil

    2012-02-13

    The characterization of dyes in various solvents requires determination of the absorption spectrum of the dye as well as the refractive index of the solvent. Typically, the refractive index of the solvent and the absorption spectrum of the solute are measured using separate experimental setups where significant liquid volumes are required. In this work the first optical measurement system that is able to do simultaneous measurements of the refractive index of the solvent and the spectral properties of the solute in a microscopic volume is presented. The laser dye Rhodamine 6G in glycerol is investigated, and the refractive index of the solution is monitored using the interference pattern of the light scattered off the channel, while its spectral properties is found by monitoring reflected light from the channel.

  3. Two classes of capillary optical fibers: refractive and photonic

    NASA Astrophysics Data System (ADS)

    Romaniuk, Ryszard S.

    2008-11-01

    This paper is a digest tutorial on some properties of capillary optical fibers (COF). Two basic types of capillary optical fibers are clearly distinguished. The classification is based on propagation mechanism of optical wave. The refractive, singlemode COF guides a dark hollow beam of light (DHB) with zero intensity on fiber axis. The photonic, singlemode COF carries nearly a perfect axial Gaussian beam with maximum intensity on fiber axis. A subject of the paper are these two basic kinds of capillary optical fibers of pure refractive and pure photonic mechanism of guided wave transmission. In a real capillary the wave may be transmitted by a mixed mechanism, refractive and photonic, with strong interaction of photonic and refractive guided wave modes. Refractive capillary optical fibers are used widely for photonic instrumentation applications, while photonic capillary optical fibers are considered for trunk optical communications. Replacement of classical, single mode, dispersion shifted, 1550nm optimized optical fibers for communications with photonic capillaries would potentially cause a next serious revolution in optical communications. The predictions say that such a revolution may happen within this decade. This dream is however not fulfilled yet. The paper compares guided modes in both kinds of optical fiber capillaries: refractive and photonic. The differences are emphasized indicating prospective application areas of these fibers.

  4. LASIK for Spherical Refractive Myopia: Effect of Topographic Astigmatism (Ocular Residual Astigmatism, ORA) on Refractive Outcome

    PubMed Central

    Frings, Andreas; Richard, Gisbert; Steinberg, Johannes; Skevas, Christos; Druchkiv, Vasyl; Katz, Toam; Linke, Stephan J.

    2015-01-01

    Purpose In eyes with a preoperative plano refractive cylinder, it would appear that there is no rationale for astigmatic treatment. The aim of this retrospective, cross-sectional data analysis was to determine the amount of topographic astigmatism in refractive plano eyes that results in reduced efficacy after myopic laser in situ keratomileusis (LASIK). Methods This study included 267 eyes from 267 consecutive myopic patients with a refractive plano cylinder. Receiver operating characteristic analysis was used to find the cut-off values of preoperative ocular residual astigmatism (= topographic astigmatism) that can best discriminate between groups of efficacy and safety indices in preoperative plano refractive cylinder eyes. Results Preoperative ocular residual astigmatism (ORA) (or topographic astigmatism) of ≤0.9 diopters (D) resulted in an efficacy index of at least 0.8 statistically significantly more frequently than eyes with a preoperative ORA of >0.9 D. Eyes with a high ORA preoperatively also had a high ORA postoperatively. Regression analysis showed that each diopter of preoperative ORA reduced efficacy by 0.07. Conclusion A preoperative corneal astigmatism of ≥0.9 D could (partially) be taken into account in the LASIK design, even if the subjective refractive astigmatism is neutral. PMID:25875476

  5. Refractive index and absorption detector for liquid chromatography based on Fabry-Perot interferometry

    DOEpatents

    Yeung, E.S.; Woodruff, S.D.

    1984-06-19

    A refractive index and absorption detector are disclosed for liquid chromatography. It is based in part on a Fabry-Perot interferometer and is used for the improved detection of refractive index and absorption. It includes a Fabry-Perot interferometer having a normally fixed first partially reflecting mirror and a movable second partially reflecting mirror. A chromatographic flow-cell is positioned between the mirrors along the optical axis of a monochromatic laser beam passing through the interferometer. A means for deriving information about the interference fringes coming out of the interferometer is used with a mini-computer to compute the refractive index of the specimen injected into the flow cell. The minicomputer continuously scans the interferometer for continuous refractive index readings and outputs the continuous results of the scans on a chart recorder. The absorption of the specimen can concurrently be scanned by including a second optical path for an excitation laser which will not interfere with the first laser, but will affect the specimen so that absorption properties can be detected. By first scanning for the refractive index of the specimen, and then immediately adding the excitation laser and subsequently scanning for the refractive index again, the absorption of the specimen can be computed and recorded. 10 figs.

  6. Relationship between lenticular power and refractive error in children with hyperopia.

    PubMed

    Tomomatsu, Takeshi; Kono, Shinjiro; Arimura, Shogo; Tomomatsu, Yoko; Matsumura, Takehiro; Takihara, Yuji; Inatani, Masaru; Takamura, Yoshihiro

    2013-01-01

    To evaluate the contribution of axial length, and lenticular and corneal power to the spherical equivalent refractive error in children with hyperopia between 3 and 13 years of age, using noncontact optical biometry. There were 62 children between 3 and 13 years of age with hyperopia (+2 diopters [D] or more) who underwent automated refraction measurement with cycloplegia, to measure spherical equivalent refractive error and corneal power. Axial length was measured using an optic biometer that does not require contact with the cornea. The refractive power of the lens was calculated using the Sanders-Retzlaff-Kraff formula. Single regression analysis was used to evaluate the correlation among the optical parameters. There was a significant positive correlation between age and axial length (P = 0.0014); however, the degree of hyperopia did not decrease with aging (P = 0.59). There was a significant negative correlation between age and the refractive power of the lens (P = 0.0001) but not that of the cornea (P = 0.43). A significant negative correlation was observed between the degree of hyperopia and lenticular power (P < 0.0001). Although this study is small scale and cross sectional, the analysis, using noncontact biometry, showed that lenticular power was negatively correlated with refractive error and age, indicating that lower lens power may contribute to the degree of hyperopia.

  7. Influence of refractive condition on retinal vasculature complexity in younger subjects.

    PubMed

    Azemin, Mohd Zulfaezal Che; Daud, Norsyazwani Mohamad; Ab Hamid, Fadilah; Zahari, Ilyanoon; Sapuan, Abdul Halim

    2014-01-01

    The aim of this study was to compare the retinal vasculature complexity between emmetropia, and myopia in younger subjects. A total of 82 patients (24.12 ± 1.25 years) with two types of refractive conditions, myopia and emmetropia were enrolled in this study. Refraction data were converted to spherical equivalent refraction. These retinal images (right eyes) were obtained from NAVIS Lite Image Filing System and the vasculature complexity was measured by fractal dimension (D f ), quantified using a computer software following a standardized protocol. There was a significant difference (P < 0.05) in the value of D f between emmetropic (1.5666 ± 0.0160) and myopic (1.5588 ± 0.0142) groups. A positive correlation (rho = 0.260, P < 0.05) between the D f and the spherical equivalent refraction was detected in this study. Using a linear model, it was estimated that 6.7% of the variation in D f could be explained by spherical equivalent refraction. This study provides valuable findings about the effect of moderate to high myopia on the fractal dimension of the retinal vasculature network. These results show that myopic refraction in younger subjects was associated with a decrease in D f , suggesting a loss of retinal vessel density with moderate to high myopia.

  8. Reflective and refractive objects for mixed reality.

    PubMed

    Knecht, Martin; Traxler, Christoph; Winklhofer, Christoph; Wimmer, Michael

    2013-04-01

    In this paper, we present a novel rendering method which integrates reflective or refractive objects into a differential instant radiosity (DIR) framework usable for mixed-reality (MR) applications. This kind of objects are very special from the light interaction point of view, as they reflect and refract incident rays. Therefore they may cause high-frequency lighting effects known as caustics. Using instant-radiosity (IR) methods to approximate these high-frequency lighting effects would require a large amount of virtual point lights (VPLs) and is therefore not desirable due to real-time constraints. Instead, our approach combines differential instant radiosity with three other methods. One method handles more accurate reflections compared to simple cubemaps by using impostors. Another method is able to calculate two refractions in real-time, and the third method uses small quads to create caustic effects. Our proposed method replaces parts in light paths that belong to reflective or refractive objects using these three methods and thus tightly integrates into DIR. In contrast to previous methods which introduce reflective or refractive objects into MR scenarios, our method produces caustics that also emit additional indirect light. The method runs at real-time frame rates, and the results show that reflective and refractive objects with caustics improve the overall impression for MR scenarios.

  9. The relationship between the retinal image quality and the refractive index of defects arising in IOL: numerical analysis

    NASA Astrophysics Data System (ADS)

    Geniusz, Malwina

    2017-09-01

    The best treatment for cataract patients, which allows to restore clear vision is implanting an artificial intraocular lens (IOL). The image quality of the lens has a significant impact on the quality of patient's vision. After a long exposure the implant to aqueous environment some defects appear in the artificial lenses. The defects generated in the IOL have different refractive indices. For example, glistening phenomenon is based on light scattering on the oval microvacuoles filled with an aqueous humor which refractive index value is about 1.34. Calcium deposits are another example of lens defects and they can be characterized by the refractive index 1.63. In the presented studies it was calculated how the difference between the refractive indices of the defect and the refractive index of the lens material affects the quality of image. The OpticStudio Professional program (from Radiant Zemax, LLC) was used for the construction of the numerical model of the eye with IOL and to calculate the characteristics of the retinal image. Retinal image quality was described in such characteristics as Point Spread Function (PSF) and the Optical Transfer Function with amplitude and phase. The results show a strong correlation between the refractive indices difference and retinal image quality.

  10. Determining the unique refractive index properties of solid polystyrene aerosol using broadband Mie scattering from optically trapped beads.

    PubMed

    Jones, Stephanie H; King, Martin D; Ward, Andrew D

    2013-12-21

    A method is described to measure the refractive index dispersion with wavelength of optically trapped solid particles in air. Knowledge of the refraction properties of solid particles is critical for the study of aerosol; both in the laboratory and in the atmosphere for climate studies. Single micron-sized polystyrene beads were optically trapped in air using a vertically aligned counter-propagating configuration of focussed laser beams. Each bead was illuminated using white light from a broadband light emitting diode (LED) and elastic scattering within the bead was collected onto a spectrograph. The resulting Mie spectra were analysed to accurately determine polystyrene bead radii to ±0.4 nm and values of the refractive index to ±0.0005 over a wavelength range of 480-700 nm. We demonstrate that optical trapping combined with elastic scattering can be used to both accurately size polystyrene beads suspended in air and determine their wavelength dependent refractive index. The refractive index dispersions are in close agreement with reported values for polystyrene beads in aqueous dispersion. Our results also demonstrate a variation in the refractive index of polystyrene, from bead to bead, in a commercial sample. The measured variation highlights that care must be taken when using polystyrene beads as a calibration aerosol.

  11. New analytical technique for carbon dioxide absorption solvents

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pouryousefi, F.; Idem, R.O.

    2008-02-15

    The densities and refractive indices of two binary systems (water + MEA and water + MDEA) and three ternary systems (water + MEA + CO{sub 2}, water + MDEA + CO{sub 2}, and water + MEA + MDEA) used for carbon dioxide (CO{sub 2}) capture were measured over the range of compositions of the aqueous alkanolamine(s) used for CO{sub 2} absorption at temperatures from 295 to 338 K. Experimental densities were modeled empirically, while the experimental refractive indices were modeled using well-established models from the known values of their pure-component densities and refractive indices. The density and Gladstone-Dale refractive indexmore » models were then used to obtain the compositions of unknown samples of the binary and ternary systems by simultaneous solution of the density and refractive index equations. The results from this technique have been compared with HPLC (high-performance liquid chromatography) results, while a third independent technique (acid-base titration) was used to verify the results. The results show that the systems' compositions obtained from the simple and easy-to-use refractive index/density technique were very comparable to the expensive and laborious HPLC/titration techniques, suggesting that the refractive index/density technique can be used to replace existing methods for analysis of fresh or nondegraded, CO{sub 2}-loaded, single and mixed alkanolamine solutions.« less

  12. Refractive errors.

    PubMed

    Schiefer, Ulrich; Kraus, Christina; Baumbach, Peter; Ungewiß, Judith; Michels, Ralf

    2016-10-14

    All over the world, refractive errors are among the most frequently occuring treatable distur - bances of visual function. Ametropias have a prevalence of nearly 70% among adults in Germany and are thus of great epidemiologic and socio-economic relevance. In the light of their own clinical experience, the authors review pertinent articles retrieved by a selective literature search employing the terms "ametropia, "anisometropia," "refraction," "visual acuity," and epidemiology." In 2011, only 31% of persons over age 16 in Germany did not use any kind of visual aid; 63.4% wore eyeglasses and 5.3% wore contact lenses. Refractive errors were the most common reason for consulting an ophthalmologist, accounting for 21.1% of all outpatient visits. A pinhole aperture (stenopeic slit) is a suitable instrument for the basic diagnostic evaluation of impaired visual function due to optical factors. Spherical refractive errors (myopia and hyperopia), cylindrical refractive errors (astigmatism), unequal refractive errors in the two eyes (anisometropia), and the typical optical disturbance of old age (presbyopia) cause specific functional limitations and can be detected by a physician who does not need to be an ophthalmologist. Simple functional tests can be used in everyday clinical practice to determine quickly, easily, and safely whether the patient is suffering from a benign and easily correctable type of visual impairment, or whether there are other, more serious underlying causes.

  13. Reduced vision and refractive errors, results from a school vision screening program in Kanchanpur District of far western Nepal.

    PubMed

    Awasthi, S; Pant, B P; Dhakal, H P

    2010-01-01

    At present there is no data available on reduced vision and refractive errors in school children of far western Nepal. So, school screening records were used to obtain data useful for planning of refractive services. Data are provided from school screening conducted by Geta Eye Hospital during February/March 2008. The cases with complete data sets on visual acuity, refractive error and age were included and analyzed using computer software. Of 1165 children (mean age 11.6 ± 2.5 years) examined, 98.8% (n = 1151) had uncorrected visual acuity of 6/9 and better in at least one eye whereas 1.2% (n = 14) had acuity 6/12 and worse in both eyes. Among them, either eye of 9 children improved to 6/9 and better with correction. However, visual acuity was 6/12 and worse in both eyes of 5 children even after correction. There were 24 children with refractive errors (myopia, 1.54%; n = 18 and hypermetropia, 0.51%; n = 6) in at least one eye. The spherical equivalent refraction was not significantly different with age and gender. The incidence of reduced vision and refractive errors among school children of this semi rural district were low.

  14. The patterns of refractive errors among the school children of rural and urban settings in Nepal.

    PubMed

    Pokharel, A; Pokharel, P K; Das, H; Adhikari, S

    2010-01-01

    The uncorrected refractive error is an important cause of childhood blindness and visual impairment. To study the patterns of refractive errors among the urban and rural school going children of Nepal. A total of 440 school children of urban and rural schools within the age range of 7-15 years were selected for this study using multi-stage randomization technique. The overall prevalance of refractive error in school children was 19.8 %. The commonest refractive error among the students was myopia (59.8 %), followed by hypermetropia (31.0 %). The children of age group 12-15 years had the higher prevalence of myopia as compared to the younger counterparts (42.5 % vs 17.2 %). The prevalence of myopia was 15.5 % among the urban students as compared to 8.2 % among the rural ones (RR = 1.89, 95 % CI = 1.1-3.24). The hypermetropia was more common in urban students than in rural ones (6.4 %) vs 5.9 %, RR = 1.08 (95 % CI: 0.52-2.24). The prevalence of refractive error in the school children of Nepal is 19.8 %. The students from urban settings are more likely to have refractive error than their rural counterparts. © Nepal Ophthalmic Society.

  15. Response to Comment on "Is the nuclear refractive index lower than cytoplasm? Validation of phase measurements and implications for light scattering technologies": A Comment on "How a phase image of a cell with nucleus refractive index smaller than that of the cytoplasm should look like?", e201800033.

    PubMed

    Steelman, Zachary A; Eldridge, Will J; Wax, Adam

    2018-06-01

    Recently, Maxim A. Yurkin commented on our paper "Is the nuclear refractive index lower than cytoplasm? Validation of phase measurements and implications for light scattering technologies" as well as on a complementary study "Cell nuclei have lower refractive index and mass density than cytoplasm" from Schürmann et al. In his comment, Yurkin concluded that quantitative phase images of cells with nuclei that are less optically dense than the cytoplasm must exhibit a characteristic concavity, the absence of which is evidence against our conclusion of a less-dense nucleus. In this response, we suggest that Yurkin's conclusion is reached through an oversimplification of the spatial refractive index distribution within cells, which does not account for high index inclusions such as the nucleolus. We further cite recent studies in 3-dimensional refractive index imaging, in which the preponderance of studies supports our conclusion. Finally, we comment on the current state of knowledge regarding subcellular refractive index distributions in living cells. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  16. Refractive index and absorption detector for liquid chromatography based on Fabry-Perot interferometry

    DOEpatents

    Yeung, Edward S.; Woodruff, Steven D.

    1984-06-19

    A refractive index and absorption detector for liquid chromatography. It is based in part on a Fabry-Perot interferometer and is used for the improved detection of refractive index and absorption. It includes a Fabry-Perot interferometer having a normally fixed first partially reflecting mirror and a movable second partially reflecting mirror. A chromatographic flow-cell is positioned between the mirrors along the optical axis of a monochromatic laser beam passing through the interferometer. A means for deriving information about the interference fringes coming out of the interferometer is used with a mini-computer to compute the refractive index of the specimen injected into the flow cell. The minicomputer continuously scans the interferometer for continuous refractive index readings and outputs the continuous results of the scans on a chart recorder. The absorption of the specimen can concurrently be scanned by including a second optical path for an excitation laser which will not interfere with the first laser, but will affect the specimen so that absorption properties can be detected. By first scanning for the refractive index of the specimen, and then immediately adding the excitation laser and subsequently scanning for the refractive index again, the absorption of the specimen can be computed and recorded.

  17. Effect of Refractive Index of Substrate on Fabrication and Optical Properties of Hybrid Au-Ag Triangular Nanoparticle Arrays

    PubMed Central

    Liu, Jing; Chen, Yushan; Cai, Haoyuan; Chen, Xiaoyi; Li, Changwei; Yang, Cheng-Fu

    2015-01-01

    In this study, the nanosphere lithography (NSL) method was used to fabricate hybrid Au-Ag triangular periodic nanoparticle arrays. The Au-Ag triangular periodic arrays were grown on different substrates, and the effect of the refractive index of substrates on fabrication and optical properties was systematically investigated. At first, the optical spectrum was simulated by the discrete dipole approximation (DDA) numerical method as a function of refractive indexes of substrates and mediums. Simulation results showed that as the substrates had the refractive indexes of 1.43 (quartz) and 1.68 (SF5 glass), the nanoparticle arrays would have better refractive index sensitivity (RIS) and figure of merit (FOM). Simulation results also showed that the peak wavelength of the extinction spectra had a red shift when the medium’s refractive index n increased. The experimental results also demonstrated that when refractive indexes of substrates were 1.43 and 1.68, the nanoparticle arrays and substrate had better adhesive ability. Meanwhile, we found the nanoparticles formed a large-scale monolayer array with the hexagonally close-packed structure. Finally, the hybrid Au-Ag triangular nanoparticle arrays were fabricated on quartz and SF5 glass substrates and their experiment extinction spectra were compared with the simulated results.

  18. Pressure sensing in high-refractive-index liquids using long-period gratings nanocoated with silicon nitride.

    PubMed

    Smietana, Mateusz; Bock, Wojtek J; Mikulic, Predrag; Chen, Jiahua

    2010-01-01

    The paper presents a novel pressure sensor based on a silicon nitride (SiNx) nanocoated long-period grating (LPG). The high-temperature, radio-frequency plasma-enhanced chemical-vapor-deposited (RF PECVD) SiNx nanocoating was applied to tune the sensitivity of the LPG to the external refractive index. The technique allows for deposition of good quality, hard and wear-resistant nanofilms as required for optical sensors. Thanks to the SiNx nanocoating it is possible to overcome a limitation of working in the external-refractive-index range, which for a bare fiber cannot be close to that of the cladding. The nanocoated LPG-based sensing structure we developed is functional in high-refractive-index liquids (nD>1.46) such as oil or gasoline, with pressure sensitivity as high as when water is used as a working liquid. The nanocoating developed for this experiment not only has the highest refractive index ever achieved in LPGs (n>2.2 at λ=1,550 nm), but is also the thinnest (<100 nm) able to tune the external-refractive-index sensitivity of the gratings. To the best of our knowledge, this is the first time a nanocoating has been applied on LPGs that is able to simultaneously tune the refractive-index sensitivity and to enable measurements of other parameters.

  19. Nonintrusive measurement of the liquid refractive index by using properties of the cuvette wall.

    PubMed

    Xu, Ming; Ren, Junpeng; Miao, Runcai; Zhang, Zongquan

    2016-10-01

    We present a method of nonintrusive measurement of the refractive index of a liquid in a glass cuvette, which uses some optical properties of the cuvette wall and the principle of total internal reflection. By coating a transmission-scattering paint layer on the outer surface of the cuvette, we transform an incident laser beam into a transmitted scattered light. When the transmitted scattered light reaches the interface between the container wall and the liquid inside, the light beams satisfying the condition of total internal reflection are reflected to the coating layer, automatically forming a circular dark pattern that is related to the refractive index of the liquid. Based on an analytic relation between the diameter of the circular dark pattern and the refractive index of the liquid, we devised a method of in situ nonintrusive refractive index measurement. We tested the effect of several parameters on the measuring accuracy and found that the optimal thickness of the transmission-scattering layer is in the range of 50-70 μm, and the aperture of the diaphragm should be in the range of 0.7-1.0 mm. We measured the refractive indices of ethanol, Coca Cola, and red wine, and achieved an accuracy of ±3×10-4  RIU (refractive index unit).

  20. Assumption-free estimation of the genetic contribution to refractive error across childhood.

    PubMed

    Guggenheim, Jeremy A; St Pourcain, Beate; McMahon, George; Timpson, Nicholas J; Evans, David M; Williams, Cathy

    2015-01-01

    Studies in relatives have generally yielded high heritability estimates for refractive error: twins 75-90%, families 15-70%. However, because related individuals often share a common environment, these estimates are inflated (via misallocation of unique/common environment variance). We calculated a lower-bound heritability estimate for refractive error free from such bias. Between the ages 7 and 15 years, participants in the Avon Longitudinal Study of Parents and Children (ALSPAC) underwent non-cycloplegic autorefraction at regular research clinics. At each age, an estimate of the variance in refractive error explained by single nucleotide polymorphism (SNP) genetic variants was calculated using genome-wide complex trait analysis (GCTA) using high-density genome-wide SNP genotype information (minimum N at each age=3,404). The variance in refractive error explained by the SNPs ("SNP heritability") was stable over childhood: Across age 7-15 years, SNP heritability averaged 0.28 (SE=0.08, p<0.001). The genetic correlation for refractive error between visits varied from 0.77 to 1.00 (all p<0.001) demonstrating that a common set of SNPs was responsible for the genetic contribution to refractive error across this period of childhood. Simulations suggested lack of cycloplegia during autorefraction led to a small underestimation of SNP heritability (adjusted SNP heritability=0.35; SE=0.09). To put these results in context, the variance in refractive error explained (or predicted) by the time participants spent outdoors was <0.005 and by the time spent reading was <0.01, based on a parental questionnaire completed when the child was aged 8-9 years old. Genetic variation captured by common SNPs explained approximately 35% of the variation in refractive error between unrelated subjects. This value sets an upper limit for predicting refractive error using existing SNP genotyping arrays, although higher-density genotyping in larger samples and inclusion of interaction effects is expected to raise this figure toward twin- and family-based heritability estimates. The same SNPs influenced refractive error across much of childhood. Notwithstanding the strong evidence of association between time outdoors and myopia, and time reading and myopia, less than 1% of the variance in myopia at age 15 was explained by crude measures of these two risk factors, indicating that their effects may be limited, at least when averaged over the whole population.

  1. Refractive index measurement of the mouse crystalline lens using optical coherence tomography.

    PubMed

    Chakraborty, Ranjay; Lacy, Kip D; Tan, Christopher C; Park, Han Na; Pardue, Machelle T

    2014-08-01

    In recent years, there has been a growing interest for using mouse models in refractive development and myopia research. The crystalline lens is a critical optical component of the mouse eye that occupies greater than 50% of the ocular space, and significant increases in thickness with age. However, changes in refractive index of the mouse crystalline lens are less known. In this study, we examined the changes in thickness and refractive index of the mouse crystalline lens for two different strains, wild-type (WT) and a nyx mutant (nob) over the course of normal visual development or after form deprivation. Refractive index and lens thickness measurements were made on ex vivo lenses using spectral domain optical coherence tomography (SD-OCT). Comparison of refractive index measurements on 5 standard ball lenses using the SD-OCT and their known refractive indices (manufacturer provided) indicated good precision (intra-class correlation coefficient, 0.998 and Bland-Altman coefficient of repeatability, 0.116) of the SD-OCT to calculate mouse lens refractive index ex vivo. During normal visual development, lens thickness increased significantly with age for three different cohorts of mice, aged 4 (average thickness from both eyes; WT: 1.78 ± 0.03, nob: 1.79 ± 0.08 mm), 10 (WT: 2.02 ± 0.05, nob: 2.01 ± 0.04 mm) and 16 weeks (WT: 2.12 ± 0.06, nob: 2.09 ± 0.06 mm, p < 0.001). Lens thickness was not significantly different between the two strains at any age (p = 0.557). For mice with normal vision, refractive index for isolated crystalline lenses in nob mice was significantly greater than WT mice (mean for all ages; WT: 1.42 ± 0.01, nob: 1.44 ± 0.001, p < 0.001). After 4 weeks of form deprivation to the right eye using a skull-mounted goggling apparatus, a thinning of the crystalline lens was observed in both right and left eyes of goggled animals compared to their naïve controls (average from both the right and the left eye) for both strains (p = 0.052). In form deprived mice, lens refractive index was significantly different between the goggled animals and non-goggled naïve controls in nob mice, but not in WT mice (p = 0.009). Both eyes of goggled nob mice had significantly greater lens refractive index (goggled, 1.49 ± 0.01; opposite, 1.47 ± 0.03) compared to their naïve controls (1.45 ± 0.02, p < 0.05). The results presented here suggest that there are genetic differences in the crystalline lens refractive index of the mouse eye, and that the lens refractive index in mice significantly increase with form deprivation. Research applications requiring precise optical measurements of the mouse eye should take these lens refractive indices into account when interpreting SD-OCT data. Published by Elsevier Ltd.

  2. [Incidence of refractive errors with corrective aids subsequent selection].

    PubMed

    Benes, P; Synek, S; Petrová, S; Sokolová, Sidlová J; Forýtková, L; Holoubková, Z

    2012-02-01

    This study follows the occurrence of refractive errors in population and the possible selection of the appropriate type of corrective aids. Objective measurement and subsequent determination of the subjective refraction of the eye is on essential act in opotmetric practice. The file represented by 615 patients (1230 eyes) is divided according to the refractive error of myopia, hyperopia and as a control group are listed emetropic clients. The results of objective and subjective values of refraction are compared and statistically processed. The study included 615 respondents. To determine the objective refraction the autorefraktokeratometer with Placido disc was used and the values of spherical and astigmatic correction components, including the axis were recorded. These measurements were subsequently verified and tested subjectively using the trial lenses and the projection optotype to the normal investigative distance of 5 meters. After this the appropriate corrective aids were then recommended. Group I consists of 123 men and 195 women with myopia (n = 635) of clients with an average age 39 +/- 18,9 years. Objective refraction - sphere: -2,57 +/- 2,46 D, cylinder: -1,1 +/- 1,01 D, axis of: 100 degrees +/- 53,16 degrees. Subjective results are as follows--the value of sphere: -2,28 +/- 2,33 D, cylinder -0,63 +/- 0,80 D, axis of: 99,8 degrees +/- 56,64 degrees. Group II is represented hyperopic clients and consists of 67 men and 107 women (n = 348). The average age is 58,84 +/- 16,73 years. Objective refraction has values - sphere: +2,81 +/- 2,21 D, cylinder: -1,0 +/- 0,94 D; axis 95 degree +/- 45,4 degrees. Subsequent determination of subjective refraction has the following results - sphere: +2,28 +/- 2,06 D; cylinder: -0,49 +/- 0,85 D, axis of: 95,9 degrees +/- 46,4 degrees. Group III consists from emetropes whose final minimum viasual acuity was Vmin = 1,0 (5/5) or better. Overall, this control group is represented 52 males and 71 females (n = 247). The average age was 43 +/- 18,73 years. Objective refraction - sphere: +0,32 +/- 0,45 D; cylinder: -0,51 +/- 0,28 D, axis of: 94,7 degrees +/- 57,5 degrees. Values of objective refraction take higher values than the subsequent execution of the subjective examination of the refractive error and recommendation of the appropriate type of corrective aids. This all is in examined groups and in the individual components of refractive errors. It also confirmed the hypothesis that the population outweighs with-the-rule astigmatism, the deployment of resources according to the literature ranges from 90 degrees +/- 10 degrees. The values observed correction of refractive errors are then derived also offer the most common prescription ranges and products for the correction of given ametropia. In the selection and design corrective aids, we are often limited. Our task is then to manufacture high quality, functional and aesthetic corrective aids, you need to connect knowledge from the fields of optics, optometry and ophthalmology. Faster visual rehabilitation simplifies clients' rapid return to everyday life.

  3. The influence of a novel simulated learning environment upon student clinical subjective refraction performance: A pilot study.

    PubMed

    Woodman-Pieterse, Emily C; De Souza, Neilsen J; Vincent, Stephen J

    2016-07-01

    Optometry students are taught the process of subjective refraction through lectures and laboratory-based practicals before progressing to supervised clinical practice. Simulated leaning environments (SLEs) form part of an emerging technology used in a range of health disciplines; however, there is limited evidence regarding the effectiveness of clinical simulators as educational tools. Forty optometry students (20 fourth year and 20 fifth year) were assessed twice by a qualified optometrist (two examinations separated by four to eight weeks), while completing a monocular non-cycloplegic subjective refraction on the same patient with an unknown refractive error, simulated using contact lenses. Half of the students were granted access to an online simulated learning environment, The Brien Holden Vision Institute (BHVI) Virtual Refractor, and the remaining students formed a control group. The primary outcome measures at each visit were; accuracy of the clinical refraction compared to a qualified optometrist and relative to the Optometry Council of Australia and New Zealand (OCANZ) subjective refraction examination criteria. Secondary measures of interest included descriptors of student SLE engagement, student self-reported confidence levels and correlations between performance in the simulated and real-world clinical environment. Eighty per cent of students in the intervention group interacted with the simulated learning environment (for an average of 100 minutes); however, there was no correlation between measures of student engagement with the BHVI Virtual Refractor and speed or accuracy of clinical subjective refractions. Fifth year students were typically more confident and refracted more accurately and more quickly than fourth year students. A year group by experimental group interaction (p = 0.03) was observed for accuracy of the spherical component of refraction and post hoc analysis revealed that less experienced students exhibited greater gains in clinical accuracy following exposure to the SLE intervention. Short-term exposure to a SLE can positively influence clinical subjective refraction outcomes for less experienced optometry students and may be of benefit in increasing the skills of novice refractionists to levels appropriate for commencing supervised clinical interactions. © 2016 Optometry Australia.

  4. Visual outcomes after spectacles treatment in children with bilateral high refractive amblyopia.

    PubMed

    Lin, Pei-Wen; Chang, Hsueh-Wen; Lai, Ing-Chou; Teng, Mei-Ching

    2016-11-01

    The aim was to investigate the visual outcomes of treatment with spectacles for bilateral high refractive amblyopia in children three to eight years of age. Children with previously untreated bilateral refractive amblyopia were enrolled. Bilateral high refractive amblyopia was defined as visual acuity (VA) being worse than 6/9 in both eyes in the presence of 5.00 D or more of hyperopia, 5.00 D or more of myopia and 2.00 D or more of astigmatism. Full myopic and astigmatic refractive errors were corrected, and the hyperopic refractive errors were corrected within 1.00 D of the full correction. All children received visual assessments at four-weekly intervals. VA, Worth four-dot test and Randot preschool stereotest were assessed at baseline and every four weeks for two years. Twenty-eight children with previously untreated bilateral high refractive amblyopia were enrolled. The mean VA at baseline was 0.39 ± 0.24 logMAR and it significantly improved to 0.21, 0.14, 0.11, 0.05 and 0.0 logMAR at four, eight, 12, 24 weeks and 18 months, respectively (all p = 0.001). The mean stereoacuity (SA) was 1,143 ± 617 arcsec at baseline and it significantly improved to 701, 532, 429, 211 and 98 arcsec at four, eight, 12, 24 weeks and 18 months, respectively (all p = 0.001). The time interval for VA achieving 6/6 was significantly shorter in the eyes of low spherical equivalent (SE) (-2.00 D < SE < +2.00 D) than in those of high SE (SE > +2.00 D) (3.33 ± 2.75 months versus 8.11 ± 4.56 months, p = 0.0005). All subjects had normal fusion on Worth four-dot test at baseline and all follow-up visits. Refractive correction with good spectacles compliance improves VA and SA in young children with bilateral high refractive amblyopia. Patients with greater amounts of refractive error will achieve resolution of amblyopia with a longer time. © 2016 Optometry Australia.

  5. A Multicenter Retrospective Survey of Refractive Surgery in 78,248 Eyes.

    PubMed

    Kamiya, Kazutaka; Igarashi, Akihito; Hayashi, Ken; Negishi, Kazuno; Sato, Masaki; Bissen-Miyajima, Hiroko

    2017-09-01

    To retrospectively evaluate the current practice, trends, and outcomes of refractive surgery in Japan. This multicenter survey comprised 78,248 eyes of 39,727 consecutive patients who underwent refractive surgery at 45 major institutions in Japan. The corresponding ophthalmologists responded to a selfadministered questionnaire. The authors especially evaluated the safety, efficacy, predictability, stability, and adverse events of LASIK and phakic intraocular lens (IOL) implantation 3 months postoperatively. The most common refractive surgery was LASIK (90.9%), followed by corneal inlay (5.0%), posterior chamber phakic IOL implantation (1.3%), laser-assisted subepithelial keratomileusis (1.0%), refractive lens exchange (0.9%), photorefractive keratectomy (0.3%), and refractive lenticule extraction (0.2%). For subgroup analysis, 69,987 eyes (99.5%) and 67,512 eyes (95.9%) achieved corrected and uncorrected distance visual acuity of 20/20 or better, respectively, after LASIK, and 935 eyes (98.8%) and 890 eyes (94.1%), respectively, after phakic IOL implantation. There were 69,176 eyes (98.3%) and 908 eyes (96.0%) within ±1.00 diopter (D) of the attempted correction after LASIK and phakic IOL implantation, respectively. There were 1,926 eyes (2.7%) and 1 eye (0.1%) with changes in refraction of 1.00 D or less from 1 week to 3 months after LASIK and phakic IOL implantation, respectively. No vision-threatening complications occurred in any case. According to this survey, LASIK remains the most prevalent surgical technique in Japan. Both LASIK and phakic IOL implantation offered good safety and efficacy outcomes, yielding predictable and stable results. [J Refract Surg. 2017;33(9):598-602.]. Copyright 2017, SLACK Incorporated.

  6. Screening for refractive error among primary school children in Bayelsa state, Nigeria

    PubMed Central

    Opubiri, Ibeinmo; Pedro-Egbe, Chinyere

    2013-01-01

    Introduction Vision screening study in primary school children has not been done in Bayelsa State. This study aims to screen for refractive error among primary school children in Bayelsa State and use the data to plan for school Eye Health Program. Methods A cross sectional study on screening for refractive error in school children was carried out in Yenagoa Local Government Area of Bayelsa State in June 2009. A multistage sampling technique was used to select the study population (pupils aged between 5-15 years). Visual acuity (VA) for each eye, was assessed outside the classroom at a distance of 6 meters. Those with VA ≤6/9 were presented with a pinhole and the test repeated. Funduscopy was done inside a poorly lit classroom. An improvement of the VA with pinhole was considered refractive error. Data was analyzed with EPI INFO version 6. Results A total of 1,242 school children consisting of 658 females and 584 males were examined.About 97.7% of pupils had normal VA (VA of 6/6) while 56 eyes had VAs ≤ 6/9. Of these 56 eyes, the visual acuity in 49 eyes (87.5%) improved with pinhole. Twenty seven pupils had refractive error, giving a prevalence of 2.2%. Refractive error involved both eyes in 22 pupils (81.5%) and the 8-10 years age range had the highest proportion (40.7%) of cases of refractive error followed by the 9-13 year-old age range (37%). Conclusion The prevalence of refractive error was 2.2% and most eyes (97.7%) had normal vision. PMID:23646210

  7. High-refractive index polyacrylates based on quinolinone-structures for intraocular lenses

    NASA Astrophysics Data System (ADS)

    Dams, Christian; Helmstetter, Simon; Hampp, Norbert

    2017-02-01

    Intraocular lenses (IOL) have experienced an expanding application over the last decades. Not only they can be used to cure cataract caused blindness, but they are also appointed to ease visual impairments (e.g. -18 - 10 dioptre or astigmatism).[1] These phake IOL require materials with very high refractive indices due to the limited space at the implanting position in the eye of the patient. This enables less invasive operations and such with smaller incisions.[2] Quinolinone derivates, like carbostyril, are currently known from drug design and as a main structural component of several antibiotics.[3] Although they show high refractive indices and good dispersions they have not yet been used in materials for ophthalmic applications. We synthesized and characterized novel high refractive index polymers containing quinolinones as the main refractive unit of the structure.[4] We showed that it was possible to build quinolinone polymers with high refractive indices up to 1.685 at 589 nm. Using this material it would theoretically be possible to reduce the lens thickness of an IOL to under 40 percent compared to a commercial hydrogel lens with a refractive index of 1.470. We also used the synthesized quinolinone acrylates to create hydrophobic copolymers with improved physical properties and high transmission in the visible spectral range. Besides the good lightfastness these copolymers also showed very low tendencies of glistening. In conclusion quinolinones show attractive performances for the usage as a component in acrylic copolymers. If the requirements for IOL keep rising in the coming years these monomers could be used to boost the refractive index of ophthalmic polymer compositions.

  8. Correlation between refraction level and retinal breaks in myopic eye.

    PubMed

    Alimanović-Halilović, Emina

    2008-11-01

    In this study we analyzed 180 myopic eyes in order to determine the refraction that is "critical" for the occurrence of retinal breaks as a main cause of retinal detachment. Detachment of retina involves separation of the neurosensory retina from the pigmented epithelium with the severe impairment of vision. After the focused ophthalmological assessment, determination of objective refraction, indirect binocular ophthalmoscopy, we compared the diagnosed retinal breaks according to the shape with the refraction. All the examined eyes were divided into six groups according to the axis length. Mean age of our patients was between 48,43 and 51,60 years with SD ranging from 13,88 to 18,45. The age differences among the groups were not statistically significant. This study included 102 (56,7%) male and 78 (43,3%) female patients and no statistically significant differences between genders was found regarding the occurrence of retinal breaks compared to refraction. The most dominant ruptures were the round ones (28,2%), followed by oval (25%), the category of multiple small holes (19,2%), horseshoe shaped (15,3%), and finally holes with operculum. In cases with myopic refraction ranging between 3,50 and 7,49 dsph, the frequency of retinal breaks statistically significantly differs from all other analyzed refractions. Also, there is positive correlation between the above mentioned myopic refraction and the frequency of retinal breaks. In order to prevent retinal detachment in a myopic eye, we suggest further thorough examinations of the eye fundus in patients with the above mentioned myopia. Diagnosing retinal breaks involves the application of adequate therapy: laser photocoagulation, cryotherapy, sclera buckling and pneumatic retinopexy.

  9. Cycloplegic refraction is the gold standard for epidemiological studies.

    PubMed

    Morgan, Ian G; Iribarren, Rafael; Fotouhi, Akbar; Grzybowski, Andrzej

    2015-09-01

    Many studies on children have shown that lack of cycloplegia is associated with slight overestimation of myopia and marked errors in estimates of the prevalence of emmetropia and hyperopia. Non-cycloplegic refraction is particularly problematic for studies of associations with risk factors. The consensus around the importance of cycloplegia in children left undefined at what age, if any, cycloplegia became unnecessary. It was often implicitly assumed that cycloplegia is not necessary beyond childhood or early adulthood, and thus, the protocol for the classical studies of refraction in older adults did not include cycloplegia. Now that population studies of refractive error are beginning to fill the gap between schoolchildren and older adults, whether cycloplegia is required for measuring refractive error in this age range, needs to be defined. Data from the Tehran Eye Study show that, without cycloplegia, there are errors in the estimation of myopia, emmetropia and hyperopia in the age range 20-50, just as in children. Similar results have been reported in an analysis of data from the Beaver Dam Offspring Eye Study. If the only important outcome measure of a particular study is the prevalence of myopia, then cycloplegia may not be crucial in some cases. But, without cycloplegia, measurements of other refractive categories as well as spherical equivalent are unreliable. In summary, the current evidence suggests that cycloplegic refraction should be considered as the gold standard for epidemiological studies of refraction, not only in children, but in adults up to the age of 50. © 2015 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  10. Global cost of correcting vision impairment from uncorrected refractive error.

    PubMed

    Fricke, T R; Holden, B A; Wilson, D A; Schlenther, G; Naidoo, K S; Resnikoff, S; Frick, K D

    2012-10-01

    To estimate the global cost of establishing and operating the educational and refractive care facilities required to provide care to all individuals who currently have vision impairment resulting from uncorrected refractive error (URE). The global cost of correcting URE was estimated using data on the population, the prevalence of URE and the number of existing refractive care practitioners in individual countries, the cost of establishing and operating educational programmes for practitioners and the cost of establishing and operating refractive care facilities. The assumptions made ensured that costs were not underestimated and an upper limit to the costs was derived using the most expensive extreme for each assumption. There were an estimated 158 million cases of distance vision impairment and 544 million cases of near vision impairment caused by URE worldwide in 2007. Approximately 47 000 additional full-time functional clinical refractionists and 18 000 ophthalmic dispensers would be required to provide refractive care services for these individuals. The global cost of educating the additional personnel and of establishing, maintaining and operating the refractive care facilities needed was estimated to be around 20 000 million United States dollars (US$) and the upper-limit cost was US$ 28 000 million. The estimated loss in global gross domestic product due to distance vision impairment caused by URE was US$ 202 000 million annually. The cost of establishing and operating the educational and refractive care facilities required to deal with vision impairment resulting from URE was a small proportion of the global loss in productivity associated with that vision impairment.

  11. Refractive index degeneration in older lenses: A potential functional correlate to structural changes that underlie cataract formation.

    PubMed

    Bahrami, Mehdi; Hoshino, Masato; Pierscionek, Barbara; Yagi, Naoto; Regini, Justyn; Uesugi, Kentaro

    2015-11-01

    A major structure/function relationship in the eye lens is that between the constituent proteins, the crystallins and the optical property of refractive index. Structural breakdown that leads to cataract has been investigated in a number of studies; the concomitant changes in the optics, namely increases in light attenuation have also been well documented. Specific changes in the refractive index gradient that cause such attenuation, however, are not well studied because previous methods of measuring refractive index require transparent samples. The X-ray Talbot interferometric method using synchrotron radiation allows for measurement of fine changes in refractive index through lenses with opacities. The findings of this study on older human lenses show disruptions to the refractive index gradient and in the refractive index contours. These disruptions are linked to location in the lens and occur in polar regions, along or close to the equatorial plane or in lamellar-like formations. The disruptions that are seen in the polar regions manifest branching formations that alter with progression through the lens with some similarity to lens sutures. This study shows how the refractive index gradient, which is needed to maintain image quality of the eye, may be disturbed and that this can occur in a number of distinct ways. These findings offer insight into functional changes to a major optical parameter in older lenses. Further studies are needed to elicit how these may be related to structural degenerations reported in the literature. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.

  12. High Prevalence of Refractive Errors in 7 Year Old Children in Iran.

    PubMed

    Hashemi, Hassan; Yekta, Abbasali; Jafarzadehpur, Ebrahim; Ostadimoghaddam, Hadi; Etemad, Koorosh; Asharlous, Amir; Nabovati, Payam; Khabazkhoob, Mehdi

    2016-02-01

    The latest WHO report indicates that refractive errors are the leading cause of visual impairment throughout the world. The aim of this study was to determine the prevalence of myopia, hyperopia, and astigmatism in 7 yr old children in Iran. In a cross-sectional study in 2013 with multistage cluster sampling, first graders were randomly selected from 8 cities in Iran. All children were tested by an optometrist for uncorrected and corrected vision, and non-cycloplegic and cycloplegic refraction. Refractive errors in this study were determined based on spherical equivalent (SE) cyloplegic refraction. From 4614 selected children, 89.0% participated in the study, and 4072 were eligible. The prevalence rates of myopia, hyperopia and astigmatism were 3.04% (95% CI: 2.30-3.78), 6.20% (95% CI: 5.27-7.14), and 17.43% (95% CI: 15.39-19.46), respectively. Prevalence of myopia (P=0.925) and astigmatism (P=0.056) were not statistically significantly different between the two genders, but the odds of hyperopia were 1.11 (95% CI: 1.01-2.05) times higher in girls (P=0.011). The prevalence of with-the-rule astigmatism was 12.59%, against-the-rule was 2.07%, and oblique 2.65%. Overall, 22.8% (95% CI: 19.7-24.9) of the schoolchildren in this study had at least one type of refractive error. One out of every 5 schoolchildren had some refractive error. Conducting multicenter studies throughout the Middle East can be very helpful in understanding the current distribution patterns and etiology of refractive errors compared to the previous decade.

  13. Refractive surgery in Israel Defense Forces recruits.

    PubMed

    Horowitz, Josepha; Mezer, Eedy; Shochat, Tzippora; Mandel, Yossi; Buckman, Gila; Sasson, Adi; Geyer, Orna

    2008-02-01

    To determine the prevalence of refractive surgery history in recruits for military service in the Israel Defense Forces (IDF) between 1998 to 2005 and to evaluate the effect of surgery on the recruits' fitness to serve in combat units. Surgeon General's HQ, Medical Corps, Israel Defense Forces. The computerized medical records of all ametropic Israeli army inductees were reviewed. They included spectacle-wearing, contact lens-wearing, and post refractive-surgery individuals who were examined in the recruitment office before their compulsory military service. The extracted data from the personal files consisted of the assignment to combat units of those who had refractive surgery and those who wore corrective eyewear and the first and last military position of all ametropic recruits who were assigned to combat units. Five hundred ninety-seven inductees (513 men, 84 women) had refractive surgery before their military service during the study period. The prevalence of recruits who had refractive surgery increased from 0.8/1000 ametropes in 1998 to 4.9/1000 ametropes in 2005. Significantly more recruits who had surgery (73.5%) than recruits who wore corrective eyewear were assigned to combat units (P<.001). The dropout rate from combat units of the former was significantly lower than that of the latter (13.1% versus 29.2%) (P<.001). More corrective eyewear users had refractive surgery before their IDF military service, and relatively more of them applied for combat duty. The high percentage of recruits who had refractive surgery who serve uninterruptedly in combat units indicates that the procedure has no deleterious effect on the recruits' fitness.

  14. Homodyne chiral polarimetry for measuring thermo-optic refractive index variations.

    PubMed

    Twu, Ruey-Ching; Wang, Jhao-Sheng

    2015-10-10

    Novel reflection-type homodyne chiral polarimetry is proposed for measuring the refractive index variations of a transparent plate under thermal impact. The experimental results show it is a simple and useful method for providing accurate measurements of refractive index variations. The measurement can reach a resolution of 7×10-5.

  15. Interferometric studies of the refractive indices of some fluorine compounds

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Malik, Jim Gorden; Rogers, Max T.; Speirs, John L.

    1954-08-01

    It is the object of this investigation to construct an interferometer of the Rayleigh type and adapt it for two purposes; first, the measurement of the refractive indices of gases by an absolute method and, and second, the measurement of the refractive indices of very dilute solutions by the difference method.

  16. Refractive index of colloidal dispersions of spheroidal particles

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Meeten, G.H.

    1980-09-01

    The effect of particle shape on the refractive index of a colloidal dispersion of spheroidal particles is investigated theoretically, using the Rayleigh, Rayleigh- Gans-Debye, and the anomalous diffraction light-scattering approximations. It is shown that departure from particle sphericity modify the dispersion refractive index, both size and shape being of importance.

  17. Photorefractive Nonlinear Optics

    DTIC Science & Technology

    1991-01-15

    conjugate interferometer for the measurement of thin film thickness, refractive index and absorption coefficients. Also, we have investigated...conjugate interferometer for the measurement of thin film thickness, refractive index and absorption coefficients. Also, we have investigated...interaction by considering the refractive index grating as a linear superposition of the gratings from each of the frequency components of the

  18. Microwave experiments with left-handed materials

    NASA Astrophysics Data System (ADS)

    Shelby, Richard Allen

    It has previously been predicted that materials that have a simultaneous negative permittivity and negative permeability, called left-handed materials (LHM), will possess very unusual properties, such as negative refraction, inverse Doppler effect, and reversed Cherenkov radiation. In this dissertation I present results from microwave experiments designed to confirm that LHMs will exhibit negative refraction. I also present a discussion about the LHM design, and numerical, electromagnetic simulations. The experiments presented here include transmission experiments, refraction experiments, and surface plasmon experiments. The refraction experiments in Chapter 4 directly observe negative refraction for the first time. The results from the other experiments are consistent with theoretical models and support the claim that negative refraction has been observed. The materials used in the experiments presented here are fabricated, structured materials that contain fiberglass and copper with unit cell parameters on the order of millimeters. Metamaterials have been defined as being composite materials whose bulk properties are different than those of the constituent materials. By this definition, the LHMs used here are metamaterials, so long as the wavelength of the electromagnetic waves being used to probe the LHM are longer than the unit cell parameter.

  19. Application of seismic-refraction techniques to hydrologic studies

    USGS Publications Warehouse

    Haeni, F.P.

    1986-01-01

    During the past 30 years, seismic-refraction methods have been used extensively in petroleum, mineral, and engineering investigations, and to some extent for hydrologic applications. Recent advances in equipment, sound sources, and computer interpretation techniques make seismic refraction a highly effective and economical means of obtaining subsurface data in hydrologic studies. Aquifers that can be defined by one or more high seismic-velocity surfaces, such as (1) alluvial or glacial deposits in consolidated rock valleys, (2) limestone or sandstone underlain by metamorphic or igneous rock, or (3) saturated unconsolidated deposits overlain by unsaturated unconsolidated deposits,are ideally suited for applying seismic-refraction methods. These methods allow the economical collection of subsurface data, provide the basis for more efficient collection of data by test drilling or aquifer tests, and result in improved hydrologic studies.This manual briefly reviews the basics of seismic-refraction theory and principles. It emphasizes the use of this technique in hydrologic investigations and describes the planning, equipment, field procedures, and intrepretation techniques needed for this type of study.Examples of the use of seismic-refraction techniques in a wide variety of hydrologic studies are presented.

  20. Influence of surrounding media refractive index on the thermal and strain sensitivities of long-period gratings

    NASA Astrophysics Data System (ADS)

    Canute Kamikawachi, Ricardo; Rafael Collere Possetti, Gustavo; Falate, Rosane; Muller, Marcia; Luís Fabris, José

    2007-05-01

    A detailed study of the thermal and strain sensitivities of a long-period grating when the device is immersed in different external media is presented. The range of refractive indices analyzed are within 1.000 to 1.447, corresponding to samples of air, water, ethanol, naphtha, thinner, turpentine, and kerosene. Within the same range of refractive indices, the strain sensitivity is between (-0.24 ± 0.03) and (-0.94 ± 0.11) pm/μɛ. For the grating immersed in these fluids, the refractive index sensitivity ranges from -3 to -1035.6 nm per refractive index units. The coupling thermo-optic coefficients and the strain-optic coefficients are also measured, resulting in the range from (2.45 ± 0.04)×10-5 to (15.89 ± 0.82)×10-5 deg C-1 and (-1.15 ± 0.04) to (-1.61 ± 0.04) μɛ-1, respectively. A noticeable nonlinear behavior of the thermal sensitivity is found for external media with refractive indices higher than 1.430.

Top