Sample records for refractometry

  1. Digital Refractometry of Piezoelectric Crystals.

    DTIC Science & Technology

    Digital Refractometry , Included in the report is a description of the program, classical methods for measuring the refractive index, the foundations of...Digital Refractometry for isotropic and anisotropic materials and the laboratory configuration for Digital Refractometry . In the final section of the

  2. Digital Refractometry of Piezoelectric Crystalline Media

    DTIC Science & Technology

    1988-11-01

    Research and Development Technical Report SLCET-TR-87-0727-1 III DIGITAL REFRACTOMETRY OF PIEZOELECTRIC CRYSTALLINE MEDIA CD Dr. Edward Collett...1L 1 DA313485 11. TITLE (include Security Classification) DIGITAL REFRACTOMETRY OF PIEZOELECTRIC CRYSTALLINE MEDIA (U) 12. PERSONAL AUTHOR(S) Dr...GROUP SUB-GROUP Lasers; quartz; dielectrics; permittivity; refractometry 9 U-1optics; millimeter waves; microwaves; crystals. ,𔄃. ABSTRACT (Continue on

  3. Study of CCD Eyepiece on T-4 Theodolite.

    DTIC Science & Technology

    1982-11-01

    11. REVIEW OF TWO-COLOR REFRACTOMETRY OBJECTIVES .....................3 III, ACHIEVEMENTS IN TWO- COLOR REFRACTOMETRY DURING THIS CONTRA...indirectly influence the questions of star catalogs. The initial efforts under this contract were addressed toward Two- Color Refractometry . This is a...in the astroposition procedure. Future efforts on other projects will consist of the return to the Two-Color Refractometry to provide a parallel

  4. Optical Materials Characterization, Final Technical Report February 1, 1978-September 30, 1978

    DTIC Science & Technology

    1979-02-01

    FIGURES PAGE Figure 1. (a) Schematic of spectrometer used for visible region refractometry . (b) Schematic of spectrometer used for non-,visible...region refractometry . Symbols: A = source, B = divided circle, C = prism table, D = collimator, E = telescope, F = collimating mirror, G = movable... refractometry . (b) Schematic of spectrometer used for non- visible region refractometry . Symbols: A = source, B = divided circle, C = prism table

  5. Refractometry and Extinguishment/Burnback Testing of Pacific Air Forces AFFF

    DTIC Science & Technology

    2006-04-01

    AFRL-ML-TY-TR-2006-4536 REFRACTOMETRY AND EXTINGUISHMENT/ BURNBACK TESTING OF PACIFIC AIR FORCES AFFF Jennifer L. Kalberer...NAME OF RESPONSIBLE PERSON 19b. TELEPHONE NUMBER (Include area code) 31-04-2006 Interim Technical Report 01-08-2005 -- 30-09-2005 Refractometry and...AFRL) performed refractometry and extinguishment/burnback tests on samples of Ansulite and 3M aqueous film forming foam (AFFF) from an overseas air

  6. Precision Stellar Catalogs and the Role of Anomalous Refraction.

    DTIC Science & Technology

    1978-01-01

    program to evaluate the use of Two Color Refractometry (TCR) for the determination of precise stel- lar positions is discussed. Various aspects of...Display Control Console Most of the electronic subsystems which are required to perform the various functions for the Two Color Refractometry are...development of the Two-Color Refractometry System. To this end, we are performing Two-Color Refractometry evaluations on components similar to those to be

  7. Review of Physical and Chemical Methods for Characterization of Fuels

    DTIC Science & Technology

    1981-12-01

    Reversed-phase chromatography REF Refractometry CAL Calorimetry POT Potentiometry CC Coordination chromatography MSB Mossbauer spectroscopy FS Flame...petroleum distillates ......... .... ........................ . .... A-2-63 Determination of the nitrogen content of shale oil furnace oil by refractometry ... refractometry ............................................ A-2-70 SAPONIFICATION NUMBER Saponification number of petroleum products.......................A-2

  8. Comparison of Manual Refraction Versus Autorefraction in 60 Diabetic Retinopathy Patients.

    PubMed

    Shirzadi, Keyvan; Shahraki, Kourosh; Yahaghi, Emad; Makateb, Ali; Khosravifard, Keivan

    2016-07-27

    The purpose of the study was to evaluate the comparison of manual refraction versus autorefraction in diabetic retinopathy patients. The study was conducted at the Be'sat Army Hospital from 2013-2015. In the present study differences between two common refractometry methods (manual refractometry and Auto refractometry) in diagnosis and follow up of retinopathy in patients affected with diabetes is investigated. Our results showed that there is a significant difference in visual acuity score of patients between manual and auto refractometry. Despite this fact, spherical equivalent scores of two methods of refractometry did not show a significant statistical difference in the patients. Although use of manual refraction is comparable with autorefraction in evaluating spherical equivalent scores in diabetic patients affected with retinopathy, but in the case of visual acuity results from these two methods are not comparable.

  9. Comparison of refractometry and biuret assay for measurement of total protein concentration in canine abdominal and pleural fluid specimens.

    PubMed

    Rose, Alexandra; Funk, Deborah; Neiger, Reto

    2016-04-01

    To compare total protein (TP) concentrations in canine pleural and abdominal fluid specimens as measured by refractometry and biuret assay. Diagnostic test evaluation. Data regarding 92 pleural and 148 abdominal fluid specimens from dogs with various diseases. TP concentrations in fluid specimens as measured by refractometry and biuret assay were recorded. Strength of association between sets of measurements was assessed by Spearman rank correlations and Bland-Altman plots. Optimal concentration cutoff for diagnostic discrimination between exudate and nonexudate was identified by construction of receiver operating characteristic curves. Median TP concentration in pleural fluid specimens was 2.7 g/dL (range, 0.3 to 4.8 g/dL) for refractometry and 2.9 g/dL (range, 0.7 to 5.8 g/dL) for biuret assay. Median TP concentration in abdominal fluid specimens was 3.5 g/dL (range, 0.1 to 6.0 g/dL) for refractometry and 3.5 g/dL (range, 0.6 to 5.7 g/dL) for biuret assay. Correlation was significant between refractometric and biuret results for pleural (ρ = 0.921) and abdominal (ρ = 0.908) fluid. Bland-Altman plots revealed bias of -0.18 g/dL for pleural fluid and -0.03 g/dL for abdominal fluid for refractometry versus biuret assay. With a TP concentration of ≥ 3 g/dL used to distinguish exudate from nonexudate, sensitivity of refractometry was 77% for pleural fluid and 80% for abdominal fluid. Specificity was 100% and 94%, respectively. Refractometry yielded acceptable results for measurement of TP concentration in canine pleural and abdominal fluid specimens, providing a more rapid and convenient method than biuret assay.

  10. Comparison of Manual Refraction Versus Autorefraction in 60 Diabetic Retinopathy Patients

    PubMed Central

    Shirzadi, Keyvan; Shahraki, Kourosh; Yahaghi, Emad; Makateb, Ali; Khosravifard, Keivan

    2016-01-01

    Aim: The purpose of the study was to evaluate the comparison of manual refraction versus autorefraction in diabetic retinopathy patients. Material and Methods: The study was conducted at the Be’sat Army Hospital from 2013-2015. In the present study differences between two common refractometry methods (manual refractometry and Auto refractometry) in diagnosis and follow up of retinopathy in patients affected with diabetes is investigated. Results: Our results showed that there is a significant difference in visual acuity score of patients between manual and auto refractometry. Despite this fact, spherical equivalent scores of two methods of refractometry did not show a significant statistical difference in the patients. Conclusion: Although use of manual refraction is comparable with autorefraction in evaluating spherical equivalent scores in diabetic patients affected with retinopathy, but in the case of visual acuity results from these two methods are not comparable. PMID:27703289

  11. On Two Color and CCD Methods for the Determination of Astronomic Position.

    DTIC Science & Technology

    1986-03-14

    INTRODUCTION .................................... 2 A. Astroposition Objectives As Related to Two-Color Refractometry .................. 2 B. Results...value for the astronomic longitude and latitude.-_ A. Astroposition Objectives As Related to Two-Color Refractometry The long term objectives consist...The interior of the box was divided into 4 bays containing the telescope, the refractometry optics, the power supplies and the refralctometry

  12. Use of refractometry for determination of psittacine plasma protein concentration.

    PubMed

    Cray, Carolyn; Rodriguez, Marilyn; Arheart, Kristopher L

    2008-12-01

    Previous studies have demonstrated both poor and good correlation of total protein concentrations in various avian species using refractometry and biuret methodologies. The purpose of the current study was to compare these 2 techniques of total protein determination using plasma samples from several psittacine species and to determine the effect of cholesterol and other solutes on refractometry results. Total protein concentration in heparinized plasma samples without visible lipemia was analyzed by refractometry and an automated biuret method on a dry reagent analyzer (Ortho 250). Cholesterol, glucose, and uric acid concentrations were measured using the same analyzer. Results were compared using Deming regression analysis, Bland-Altman bias plots, and Spearman's rank correlation. Correlation coefficients (r) for total protein results by refractometry and biuret methods were 0.49 in African grey parrots (n=28), 0.77 in Amazon parrots (20), 0.57 in cockatiels (20), 0.73 in cockatoos (36), 0.86 in conures (20), and 0.93 in macaws (38) (P< or =.01). Cholesterol concentration, but not glucose or uric acid concentrations, was significantly correlated with total protein concentration obtained by refractometry in Amazon parrots, conures, and macaws (n=25 each, P<.05), and trended towards significance in African grey parrots and cockatoos (P=.06). Refractometry can be used to accurately measure total protein concentration in nonlipemic plasma samples from some psittacine species. Method and species-specific reference intervals should be used in the interpretation of total protein values.

  13. Polarization-Difference Imaging: Biophysical Mechanisms and Engineering Applications to Visibility Enhancement in Scattering Media

    DTIC Science & Technology

    1993-07-01

    to neglect the variation in refractive Average refractive index. Using refractometry and dif. index along they axis, so that the assumed index...output. photoreceptor calls studied by refractometry and interference microscopy," J. Biophys. Biochem. Cytolol. 3, 15-33 (1957). curves) indicate...of rhodopsin in the visual Science 300, 540-52 (1978). receptor membrane," Nature (London) 386, 39-43 (1972) 26. R. Borer and S. Joseph, " Refractometry

  14. Nondestructive Biophysical Probes of the Basis and Mechanism of Resistance in Microbial Spores.

    DTIC Science & Technology

    1983-05-10

    correlated with their water content, wet density, and protoplast/sporoplast volume ratio; (2) photometric immersion refractometry was used to show that the...immersion refractometry was used to determine if dehydration of the protoplast accounts for sporal resistance to heat. These and other approaches...in above). c. Gerhardt, P., T.C. Beaman, T.R. Corner, J.T. Greenamayer and L.S. Tisa. 1981. Photometric immersion Refractometry of Bacterial Spores

  15. Assessment of 7.5% NaCl /6% Dextran-70 (HSD) Effects on Serum or Plasma Protein Determinations

    DTIC Science & Technology

    1990-12-26

    determined by modified Lowry, dye-binding, and an automated biuret method, as well as by refractometry , before, and at various times following HSD...protein concentrations determined by the biuret assay or refractometry when dextran serum concentrations exceeded 1.2 g/dl. The in vivo studies... refractometry , before, and at various times following HSD infusion in both euvolemic and hemorrhaged animals. Other studies analyzed plasma protein

  16. Validity of HydraTrend reagent strips for the assessment of hydration status.

    PubMed

    Abbey, Bryce M; Heelan, Kate A; Brown, Gregory A; Bartee, Rodrick T

    2014-09-01

    Hydration is used by athletic governing organizations for weight class eligibility. The measurement of urine specific gravity (USG) as a measure of hydration by reagent strips is a controversial issue. The purpose of this study was to determine the validity of HydraTrend reagent strips that facilitate the correction of USG for alkaline urine samples against refractometry for the assessment of USG. Fifty-one participants (33 males, age = 22.3 ± 1.3 years; 18 females, age = 22.4 ± 1.2 years) provided 84 urine samples. The samples were tested for USG using refractometry and reagent strips and for pH using reagent strips and a digital pH meter. Strong correlation coefficients were found between refractometry and reagent strips for USG (rs(82) = 0.812, p < 0.01) and between reagent strips and pH meter for pH (rs(82) = 0.939, p < 0.01). It was observed that false negative results for National Collegiate Athletic Association (NCAA) requirements (fail refractometry with USG >1.020, pass reagent strips with USG ≤1.020) occurred 39% (33/84) of the time and false negative results for National Federation of State High School Association (NFHS) requirements (fail refractometry with USG >1.025, pass reagent strips with USG ≤1.025) occurred 14% (12/84) of the time. There were no false positives (pass refractometry and fail reagent strips) for NCAA or NFHS requirements. These data show that refractometry and reagent strips have strong positive correlations. However, the risk of a false negative result leading to incorrect certification of euhydration status outweighs the benefits of the HydraTrend reagent strips for the measurement of USG.

  17. A guide to performing basic manifest refractometry.

    PubMed

    Garber, N

    2000-01-01

    Refractometry provides the ophthalmologist with the prescription that has the most plus power with the best vision. This eliminates the need for the patient accommodating to achieve clear vision at distance. Flowcharts, of the refractometry process, help the refractionist use standard procedures to accurately arrive at the correct baseline prescription for the patient's refractive state. By using the patient's history of subjective complaints, past refractive corrections, and present visual needs, the ophthalmologist then can prescribe the final prescription.

  18. Canine Antithrombin-III: Some Biochemical and Biologic Properties

    DTIC Science & Technology

    1987-06-02

    performing amino acid analyses, amino acid sequence analysis, and differential refractometry . I thank Ms. Kerry Singer for her excellent typing and...previously determined by differential refractometry at 546 nm, with a value of 0.186 ml/g for dn/dc (refractive index increment) (69). 20 •, "• 11...J ;,.-0 t.! ’ > ~ +-’ :I c: ... Q) :::J ~ w Protein concentration by refractometry = 8.29 mg/ml O.D. value at 280 nm (1:10 dilution

  19. Comparison of 3 Methods to Assess Urine Specific Gravity in Collegiate Wrestlers.

    PubMed

    Stuempfle, Kristin J.; Drury, Daniel G.

    2003-12-01

    OBJECTIVE: To investigate the reliability and validity of refractometry, hydrometry, and reagent strips in assessing urine specific gravity in collegiate wrestlers. DESIGN AND SETTING: We assessed the reliability of refractometry, hydrometry, and reagent strips between 2 trials and among 4 testers. The validity of hydrometry and reagent strips was assessed by comparison with refractometry, the criterion measure for urine specific gravity. SUBJECTS: Twenty-one National Collegiate Athletic Association Division III collegiate wrestlers provided fresh urine samples. MEASUREMENTS: Four testers measured the specific gravity of each urine sample 6 times: twice by refractometry, twice by hydrometry, and twice by reagent strips. RESULTS: Refractometer measurements were consistent between trials (R =.998) and among testers; hydrometer measurements were consistent between trials (R =.987) but not among testers; and reagent-strip measurements were not consistent between trials or among testers. Hydrometer (1.018 +/- 0.006) and reagent-strip (1.017 +/- 0.007) measurements were significantly higher than refractometer (1.015 +/- 0.006) measurements. Intraclass correlation coefficients were moderate between refractometry and hydrometry (R =.869) and low between refractometry and reagent strips (R =.573). The hydrometer produced 28% false positives and 2% false negatives, and reagent strips produced 15% false positives and 9% false negatives. CONCLUSIONS: Only the refractometer should be used to determine urine specific gravity in collegiate wrestlers during the weight-certification process.

  20. Comparison of 3 Methods to Assess Urine Specific Gravity in Collegiate Wrestlers

    PubMed Central

    Drury, Daniel G.

    2003-01-01

    Objective: To investigate the reliability and validity of refractometry, hydrometry, and reagent strips in assessing urine specific gravity in collegiate wrestlers. Design and Setting: We assessed the reliability of refractometry, hydrometry, and reagent strips between 2 trials and among 4 testers. The validity of hydrometry and reagent strips was assessed by comparison with refractometry, the criterion measure for urine specific gravity. Subjects: Twenty-one National Collegiate Athletic Association Division III collegiate wrestlers provided fresh urine samples. Measurements: Four testers measured the specific gravity of each urine sample 6 times: twice by refractometry, twice by hydrometry, and twice by reagent strips. Results: Refractometer measurements were consistent between trials (R = .998) and among testers; hydrometer measurements were consistent between trials (R = .987) but not among testers; and reagent-strip measurements were not consistent between trials or among testers. Hydrometer (1.018 ± 0.006) and reagent-strip (1.017 ± 0.007) measurements were significantly higher than refractometer (1.015 ± 0.006) measurements. Intraclass correlation coefficients were moderate between refractometry and hydrometry (R = .869) and low between refractometry and reagent strips (R = .573). The hydrometer produced 28% false positives and 2% false negatives, and reagent strips produced 15% false positives and 9% false negatives. Conclusions: Only the refractometer should be used to determine urine specific gravity in collegiate wrestlers during the weight-certification process. PMID:14737213

  1. Comparison between refraction measured by Spot Vision Screening™ and subjective clinical refractometry.

    PubMed

    de Jesus, Daniela Lima; Villela, Flávio Fernandes; Orlandin, Luis Fernando; Eiji, Fernando Naves; Dantas, Daniel Oliveira; Alves, Milton Ruiz

    2016-02-01

    The purpose of this study was to evaluate the accuracy of Spot Vision Screening™ as an autorefractor by comparing refraction measurements to subjective clinical refractometry results in children and adult patients. One-hundred and thirty-four eyes of 134 patients were submitted to refractometry by Spot and clinical refractometry under cycloplegia. Patients, students, physicians, staff and children of staff from the Hospital das Clínicas (School of Medicine, University of São Paulo) aged 7-50 years without signs of ocular disease were examined. Only right-eye refraction data were analyzed. The findings were converted in magnitude vectors for analysis. The difference between Spot Vision Screening™ and subjective clinical refractometry expressed in spherical equivalents was +0.66±0.56 diopters (D), +0.16±0.27 D for the vector projected on the 90 axis and +0.02±0.15 D for the oblique vector. Despite the statistical significance of the difference between the two methods, we consider the difference non-relevant in a clinical setting, supporting the use of Spot Vision Screening™ as an ancillary method for estimating refraction.

  2. Diagnostic accuracy of refractometer and Brix refractometer to assess failure of passive transfer in calves: protocol for a systematic review and meta-analysis.

    PubMed

    Buczinski, S; Fecteau, G; Chigerwe, M; Vandeweerd, J M

    2016-06-01

    Calves are highly dependent of colostrum (and antibody) intake because they are born agammaglobulinemic. The transfer of passive immunity in calves can be assessed directly by dosing immunoglobulin G (IgG) or by refractometry or Brix refractometry. The latter are easier to perform routinely in the field. This paper presents a protocol for a systematic review meta-analysis to assess the diagnostic accuracy of refractometry or Brix refractometry versus dosage of IgG as a reference standard test. With this review protocol we aim to be able to report refractometer and Brix refractometer accuracy in terms of sensitivity and specificity as well as to quantify the impact of any study characteristic on test accuracy.

  3. Image Contrast Immersion Method for Measuring Refractive Index Applied to Spider Silks

    DTIC Science & Technology

    2011-09-26

    12.880665. 8. A. J. Werner, “Methods in high precision refractometry of optical glasses,” Appl. Opt. 7(5), 837–843 (1968). 9. Y. S. Liu, “Direct...transparent, low visibility orb web. Refractometry is the most widely used technique for accurately measuring n for transparent media. It has been...in use for more than a century. There are several standard refractometry methods [8]. Most require a bulk sample with surfaces polished to optical

  4. Laser Induced Damage in the Eye: Study of Energy Deposition in the Retina.

    DTIC Science & Technology

    1976-06-01

    are given in appendices 1.5 and 1.6. 52. RE FE RENCES 1. Barer, R. (1957) " Refractometry and Interferometry of living cells". J. Opt. Soc. Am. 47, 545...John Wiley and Son-, N.Y. 11. Sidman, P. (1957) "The Structure and concentration of soliis in photoreceptor cells studied by refractometry and interf...34 Refractometry and Interferometry of living cells". J. Opt. Soc. Am. 47, 545. 6. Biernson, G. (1968) "Evaluation of physiological evidence for

  5. Determination of alcohol and extract concentration in beer samples using a combined method of near-infrared (NIR) spectroscopy and refractometry.

    PubMed

    Castritius, Stefan; Kron, Alexander; Schäfer, Thomas; Rädle, Matthias; Harms, Diedrich

    2010-12-22

    A new approach of combination of near-infrared (NIR) spectroscopy and refractometry was developed in this work to determine the concentration of alcohol and real extract in various beer samples. A partial least-squares (PLS) regression, as multivariate calibration method, was used to evaluate the correlation between the data of spectroscopy/refractometry and alcohol/extract concentration. This multivariate combination of spectroscopy and refractometry enhanced the precision in the determination of alcohol, compared to single spectroscopy measurements, due to the effect of high extract concentration on the spectral data, especially of nonalcoholic beer samples. For NIR calibration, two mathematical pretreatments (first-order derivation and linear baseline correction) were applied to eliminate light scattering effects. A sample grouping of the refractometry data was also applied to increase the accuracy of the determined concentration. The root mean squared errors of validation (RMSEV) of the validation process concerning alcohol and extract concentration were 0.23 Mas% (method A), 0.12 Mas% (method B), and 0.19 Mas% (method C) and 0.11 Mas% (method A), 0.11 Mas% (method B), and 0.11 Mas% (method C), respectively.

  6. Comparison between refraction measured by Spot Vision ScreeningTM and subjective clinical refractometry

    PubMed Central

    de Jesus, Daniela Lima; Villela, Flávio Fernandes; Orlandin, Luis Fernando; Eiji, Fernando Naves; Dantas, Daniel Oliveira; Alves, Milton Ruiz

    2016-01-01

    OBJECTIVE: The purpose of this study was to evaluate the accuracy of Spot Vision ScreeningTM as an autorefractor by comparing refraction measurements to subjective clinical refractometry results in children and adult patients. METHODS: One-hundred and thirty-four eyes of 134 patients were submitted to refractometry by Spot and clinical refractometry under cycloplegia. Patients, students, physicians, staff and children of staff from the Hospital das Clínicas (School of Medicine, University of São Paulo) aged 7-50 years without signs of ocular disease were examined. Only right-eye refraction data were analyzed. The findings were converted in magnitude vectors for analysis. RESULTS: The difference between Spot Vision ScreeningTM and subjective clinical refractometry expressed in spherical equivalents was +0.66±0.56 diopters (D), +0.16±0.27 D for the vector projected on the 90 axis and +0.02±0.15 D for the oblique vector. CONCLUSIONS: Despite the statistical significance of the difference between the two methods, we consider the difference non-relevant in a clinical setting, supporting the use of Spot Vision ScreeningTM as an ancillary method for estimating refraction. PMID:26934234

  7. Refractive Index Measurement of Fibers Through Fizeau Interferometry

    DTIC Science & Technology

    2013-08-01

    15. SUBJECT TERMS composite, transparent, refractive index, refractometry , interferometer 16. SECURITY CLASSIFICATION OF: 17. LIMITATION OF...transparent fibers has long presented a significant challenge. Abbe refractometry , the typical measurement technique for bulk materials and liquids

  8. European Conference on Laser Interaction with Matter (16th ECLIM), Imperial College, London, 26-30 September 1983. Book of Abstracts.

    DTIC Science & Technology

    1983-09-30

    instability by a shaped ion beam M. SAPIR, D. HAVAZALET, Negev, Israel J9 - P Soft X-ray refractometry of laser heated plasmas R. BENATTAR, Ecole...OF STADARDS - ’lS3 - A ,-a J9 SOFT X RAY REFRACTOMETRY OF LASER HEATED PLASMAS R. BENATTAR Laboratoire PMI, Ecole Polytechnique, 91128 Palaiseau...about the more appropriate wavelength to probe the high density region of a laser created plasma by refractometry . After, we show two possibilities, using

  9. 7TH International Workshop on Laser Physics (LPHYS󈨦) Berlin, Germany July 6-10, 1998 Program and Book of Abstracts: Volume 2.

    DTIC Science & Technology

    1998-07-01

    Russia)"Laser refractometry of biological media" Tuesday, July 7 Chairs: S. Gonchukov (Russia) and D. Sliney (USA) A. Priezzhev (Moscow, Russia) 11.00...application to the evaluation of blood flow. Optics and Laser Technology, Vol.23, No.4, p.205, 1991. LASER REFRACTOMETRY OF BIOLOGICAL MEDIA S.A. Gonchukov...measuring (fast-action). Refractometry is a classical technique. The sensitivity of traditional measuring is usually 10-4-10-7. That’s no bad. But

  10. Angular filter refractometry analysis using simulated annealing [An improved method for characterizing plasma density profiles using angular filter refractometry

    DOE PAGES

    Angland, P.; Haberberger, D.; Ivancic, S. T.; ...

    2017-10-30

    Here, a new method of analysis for angular filter refractometry images was developed to characterize laser-produced, long-scale-length plasmas using an annealing algorithm to iterative converge upon a solution. Angular filter refractometry (AFR) is a novel technique used to characterize the density pro files of laser-produced, long-scale-length plasmas. A synthetic AFR image is constructed by a user-defined density profile described by eight parameters, and the algorithm systematically alters the parameters until the comparison is optimized. The optimization and statistical uncertainty calculation is based on a minimization of themore » $$\\chi$$2 test statistic. The algorithm was successfully applied to experimental data of plasma expanding from a flat, laser-irradiated target, resulting in average uncertainty in the density profile of 5-10% in the region of interest.« less

  11. Angular filter refractometry analysis using simulated annealing [An improved method for characterizing plasma density profiles using angular filter refractometry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Angland, P.; Haberberger, D.; Ivancic, S. T.

    Here, a new method of analysis for angular filter refractometry images was developed to characterize laser-produced, long-scale-length plasmas using an annealing algorithm to iterative converge upon a solution. Angular filter refractometry (AFR) is a novel technique used to characterize the density pro files of laser-produced, long-scale-length plasmas. A synthetic AFR image is constructed by a user-defined density profile described by eight parameters, and the algorithm systematically alters the parameters until the comparison is optimized. The optimization and statistical uncertainty calculation is based on a minimization of themore » $$\\chi$$2 test statistic. The algorithm was successfully applied to experimental data of plasma expanding from a flat, laser-irradiated target, resulting in average uncertainty in the density profile of 5-10% in the region of interest.« less

  12. Composition measurements of binary mixture droplets by rainbow refractometry.

    PubMed

    Wilms, J; Weigand, B

    2007-04-10

    So far, refractive index measurements by rainbow refractometry have been used to determine the temperature of single droplets and ensembles of droplets. Rainbow refractometry is, for the first time, to the best of our knowledge, applied to measure composition histories of evaporating, binary mixture droplets. An evaluation method is presented that makes use of Airy theory and the simultaneous size measurement by Mie scattering imaging. The method further includes an empirical correction function for a certain diameter and refractive index range. The measurement uncertainty was investigated by numerical simulations with Lorenz-Mie theory. For the experiments, an optical levitation setup was used allowing for long measurement periods. Temperature measurements of single-component droplets at different temperature levels are shown to demonstrate the accuracy of rainbow refractometry. Measurements of size and composition histories of binary mixture droplets are presented for two different mixtures. Experimental results show good agreement with numerical results using a rapid-mixing model.

  13. United States Air Force Summer Faculty Research Program (1984). Program Management Report.

    DTIC Science & Technology

    1984-12-01

    6 Two-Color Refractometry for Dr. John D. R. Bahng Astronomical Geodesy 7 Long Wavelength infrared Emissions Dr. James C. Baird from a Recomnining...hardware, and conducting the experiment. 4 114 , -. ., -. . . . . . . . - ... . . .. . . . . . . . . . . . . . . . . . . TWO-ODLOR REFRACTOMETRY FOR

  14. Mechanisms of Resistance in Microbial Spores

    DTIC Science & Technology

    1990-12-20

    solids (and water) content by immersion refractometry . Heat-activated spores of Bacillus stearotherrnophilus were found to be separable into two...incrC· ment of bacterial cells, enabling determination of their solids content by immersion refractometry . The results agreed well with values for

  15. USSR Report, Engineering and Equipment

    DTIC Science & Technology

    1987-01-20

    determining refractive indices— refractometry —has come into being. A great variety of refractometers, designed for several different sectors of the national...S.I. Vavilova. The outcome has been what is in essence a new scientific departure—reflective refractometry of absorptive media—and the development

  16. Intelligent Processing of Ferroelectric Thin Films

    DTIC Science & Technology

    1994-05-31

    unsatisfactory. To detect the electroopic effects of thin films deposited on opaque substrates a waveguide refractometry of category 3 was reported. An advantage...of the waveguide refractometry is its capability of resolving the change in ordinary index from the change in the extraordinary index. Some successes

  17. Composition measurements of binary mixture droplets by rainbow refractometry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wilms, J.; Weigand, B

    2007-04-10

    So far, refractive index measurements by rainbow refractometry have been used to determine the temperature of single droplets and ensembles of droplets. Rainbow refractometry is, for the first time, to the best of our knowledge, applied to measure composition histories of evaporating, binary mixture droplets. An evaluation method is presented that makes use of Airy theory and the simultaneous size measurement by Mie scattering imaging. The method further includes an empirical correction function for a certain diameter and refractive index range. The measurement uncertainty was investigated by numerical simulations with Lorenz-Mie theory. For the experiments, an optical levitation setup wasmore » used allowing for long measurement periods. Temperature measurements of single-component droplets at different temperature levels are shown to demonstrate the accuracy of rainbow refractometry. Measurements of size and composition histories of binary mixture droplets are presented for two different mixtures. Experimental results show good agreement with numerical results using a rapid-mixing model.« less

  18. Optical coherence refractometry.

    PubMed

    Tomlins, Peter H; Woolliams, Peter; Hart, Christian; Beaumont, Andrew; Tedaldi, Matthew

    2008-10-01

    We introduce a novel approach to refractometry using a low coherence interferometer at multiple angles of incidence. We show that for plane parallel samples it is possible to measure their phase refractive index rather than the group index that is usually measured by interferometric methods. This is a significant development because it enables bulk refractive index measurement of scattering and soft samples, not relying on surface measurements that can be prone to error. Our technique is also noncontact and compatible with in situ refractive index measurements. Here, we demonstrate this new technique on a pure silica test piece and a highly scattering resin slab, comparing the results with standard critical angle refractometry.

  19. Laser Light: Using Laser Refractometry to Determine Concentration.

    ERIC Educational Resources Information Center

    Gauger, Robert

    1995-01-01

    Laser refractometry is a science-technology-based activity that requires students to manipulate a variety of equipment, tools, materials, and critical-thinking skills. Students use a laser to measure the percent of glucose in a solution by calibrating the system, taking measurements, and computing the concentration. (MKR)

  20. Estimate of colostral immunoglobulin G concentration using refractometry without or with caprylic acid fractionation.

    PubMed

    Morrill, K M; Conrad, E; Polo, J; Lago, A; Campbell, J; Quigley, J; Tyler, H

    2012-07-01

    Our objectives were to evaluate the use of refractometry as a means of estimating immunoglobulin G (IgG) concentration of bovine maternal colostrum (MC) and determine if fractionation of MC using caprylic acid (CA) improved estimates of IgG. Samples (n=85) of MC were collected from a single dairy in California and used to determine the method of CA fraction that produced the best prediction of IgG based on CA fractionation followed by refractometry. Subsequently, samples of MC (n=827) were collected from 67 farms in 12 states to compare refractometry with or without CA fractionation as methods to estimate IgG concentration. Samples were collected from the feeding pool and consisted of fresh (n=196), previously frozen (n=479), or refrigerated (n=152) MC. Samples were further classified by the number freeze-thaw cycles before analysis. Fractionation with CA was conducted by adding 1 mL of MC to a tube containing 75 μL of CA and 1 mL of 0.06 M acetic acid. The tube was shaken and allowed to react for 1 min. Refractive index of the IgG-rich supernatant (nDf) was determined using a digital refractometer. Whole, nonfractionated MC was analyzed for IgG by radial immunodiffusion (RID) and refractive index (nDw). The relationship between nDf and IgG (r=0.53; n=805) was weak, whereas that between nDw and IgG was stronger (r=0.73; n=823). Fresh samples analyzed by refractometry that subsequently went through 1 freeze-thaw cycle before RID analysis resulted in the strongest relationship between IgG and nDf or nDw (r=0.93 and 0.90, respectively). The MC samples collected fresh on the farm but frozen 2 or more times before analysis by refractometry or RID had low correlations between IgG and nDf and nDw (r=0.09 and 0.01). Samples refrigerated or frozen on the farm before analysis had weaker relationships between RID and nDf or nDw (r=0.38 to 0.80), regardless of the number of freeze-thaw cycles. Breed and lactation number did not affect the accuracy of either test. These results indicated that refractometry, without or with CA fractionation, was an accurate and rapid method to determine IgG concentration when samples of MC were not previously stored before refractometry and frozen only once before RID analysis. Copyright © 2012 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  1. Physics in Europe--A Data File of Selected Research.

    DTIC Science & Technology

    1984-06-18

    Negev Sapir Proc. 16th Euro. Conf. on Laser Interac. with Matter, London 26-30 Sept. 1983 1025 CPBICF laser plasma soft x-ray refractometry France...CPBICF laser plasma Schlieren diagnostic France 623 CPBICF laser plasma self focusing numerics UK 1025 CPBICF laser plasma soft x-ray refractometry

  2. Defense Small Business Innovation Research Program (SBIR). Abstracts of Phase 2 Awards. 1986

    DTIC Science & Technology

    1986-01-01

    MEASUREMENT CONCEPTS INC ARMY 41 HWY 34 SOUTH - COLTS TOWNE PLAZA COLTS NECK, NJ 07722 CONTRACT NUMBER: DR EDWARD COLLET TITLE: DIGITAL REFRACTOMETRY OF...BEAM DIGITAL REFRACTOMETRY . BY FOLLOWING A DUAL-BEAM CONFIGURATION WE SHOW THAT IT IS POSSIBLE TO OVERCOME 1) THE OPTICAL SOURCE FLUCTUATIONS, 2) THE

  3. Subjective method of refractometry and depth of focus

    PubMed Central

    Sergienko, Nikolai M.; Gromova, Anastasia; Sergienko, Nikolai

    2012-01-01

    Purpose To study the impact of the depth of focus on subjective refraction and distribution of myopic and hyperopic refractions. Methods A total of 450 eyes of 305 subjects in the age range of 23–34 years were recruited for the study. A distribution of refractions was examined using a traditional method of the subjective refractometry on the basis of point-like posterior focus notion. Correction of the results was made on the assumption that the emmetropic eye retains high visual acuity when applying convex lenses with values which are fewer or equal to the depth of focus values. The following values of the depth of focus were used: ±0.55 D, ±0.35 D and ±0.2 D for visual acuity 1.0, 1.5 and 2.0, respectively. Results Application of the traditional method of refractometry produced the following occurrence of refractions: hypermetropia 59.3%, myopia 22% and emmetropia 18.7%. After correction of the initial results of values of the depth of focus the distribution of refractions was as follows: hypermetropia 12.7%, myopia 22% and emmetropia 65.3%. Conclusion The traditional method of subjective refractometry with application of trial lenses was developed on the basis of data of large optical aberrations and significant depth of focus which values should be taken into account during interpretation of results of subjective refractometry. Our data regarding to prevalence of emmetropic refraction falls in line with basic science provisions in respect of the physiology of the eye.

  4. Applicability of refractometry for fast routine checking of hospital preparations.

    PubMed

    Hendrickx, Stijn; Verón, Aurora Monteagudo; Van Schepdael, Ann; Adams, Erwin

    2016-04-30

    Quality control of hospital pharmacy formulations is of the utmost importance to ensure constant quality and to avoid potential mistakes before administration to the patient. In this study we investigated the applicability of refractometry as a fast, inexpensive and easy-to-use quality control measurement. Refractive indices (RI) of a multitude of different hospital formulations with varying concentrations of active compound were measured. The samples consisted of a number of binary aqueous solutions (one compound in water), complex aqueous solutions (multiple compounds in water or in a constant matrix), two suspensions and one emulsion. For all these formulations, linear regression analysis was performed, quality control limits determined and accuracy and repeatability were checked. Subsequently, actual hospital pharmacy samples were analyzed to check whether they were within the specified limits. For both binary and complex aqueous formulations, repeatability was good and a linear correlation for all samples could be observed on condition that the concentration of the active compound was sufficiently high. The refractometer was not sensitive enough for solutions of folic acid and levothyroxine, which had too low a concentration of active compound. Due to lack of homogeneity and light scattering, emulsions and suspensions do not seem suitable for quality control by refractometry. A mathematical equation was generated to predict the refractive index of an aqueous solution containing clonidine HCl as active compound. Values calculated from the equation were compared with measured values and deviations of all samples were found to be lower than 1.3%. In order to use refractometry in a hospital pharmacy for quality control of multicomponent samples, additional intermediate measurements would be required, to overcome the fact that refractometry is not compound specific. In conclusion, we found that refractometry could potentially be useful for daily, fast quality measurements of relatively concentrated binary and more complex aqueous solutions in the hospital pharmacy. Copyright © 2016 Elsevier B.V. All rights reserved.

  5. Investigation of Deviations from Ideality in the Two Liquid Phase Region of Systems of Medium Molecular Weight Hydrocarbon Mixtures and Water.

    DTIC Science & Technology

    1986-02-01

    determined by refractometry using a Bausch and Lomb Refractometer (Abbe 3-L). Refractive index calibrations for the binary mixtures examined are given in...mixture sample was taken and analyzed by refractometry . b. Results The results of the vapor pressure experiments and the Redlich- Kister coefficients

  6. Subsurface imaging and cell refractometry using quantitative phase/ shear-force feedback microscopy

    NASA Astrophysics Data System (ADS)

    Edward, Kert; Farahi, Faramarz

    2009-10-01

    Over the last few years, several novel quantitative phase imaging techniques have been developed for the study of biological cells. However, many of these techniques are encumbered by inherent limitations including 2π phase ambiguities and diffraction limited spatial resolution. In addition, subsurface information in the phase data is not exploited. We hereby present a novel quantitative phase imaging system without 2 π ambiguities, which also allows for subsurface imaging and cell refractometry studies. This is accomplished by utilizing simultaneously obtained shear-force topography information. We will demonstrate how the quantitative phase and topography data can be used for subsurface and cell refractometry analysis and will present results for a fabricated structure and a malaria infected red blood cell.

  7. Is specific gravity a good estimate of urine osmolality?

    PubMed

    Imran, Sethi; Eva, Goldwater; Christopher, Shutty; Flynn, Ethan; Henner, David

    2010-01-01

    Urine specific gravity (USG) is often used by clinicians to estimate urine osmolality. USG is measured either by refractometry or by reagent strip. We studied the correlation of USG obtained by either method with a concurrently obtained osmolality. Using our laboratory's records, we retrospectively gathered data on 504 urine specimens on patients on whom a simultaneously drawn USG and an osmolality were available. Out of these, 253 USG's were measured by automated refractometry and 251 USG's were measured by reagent strip. Urinalysis data on these subjects were used to determine the correlation between USG and osmolality, adjusting for other variables that may impact the relationship. The other variables considered were pH, protein, glucose, ketones, nitrates, bilirubin, urobilinogen, hemoglobin, and leukocyte esterase. The relationships were analyzed by linear regression. This study demonstrated that USG obtained by both reagent strip and refractometry had a correlation of approximately 0.75 with urine osmolality. The variables affecting the correlation included pH, ketones, bilirubin, urobilinogen, glucose, and protein for the reagent strip and ketones, bilirubin, and hemoglobin for the refractometry method. At a pH of 7 and with an USG of 1.010 predicted osmolality is approximately 300  mosm/kg/H(2)O for either method. For an increase in SG of 0.010, predicted osmolality increases by 182  mosm/kg/H(2) O for the reagent strip and 203  mosm/kg/H(2)O for refractometry. Pathological urines had significantly poorer correlation between USG and osmolality than "clean" urines. In pathological urines, direct measurement of urine osmolality should be used. © 2010 Wiley-Liss, Inc.

  8. Gastric residual volume (GRV) and gastric contents measurement by refractometry.

    PubMed

    Chang, Wei-Kuo; McClave, Stephen A; Hsieh, Chung-Bao; Chao, You-Chen

    2007-01-01

    Traditional use of gastric residual volumes (GRVs), obtained by aspiration from a nasogastric tube, is inaccurate and cannot differentiate components of the gastric contents (gastric secretion vs delivered formula). The use of refractometry and 3 mathematical equations has been proposed as a method to calculate the formula concentration, GRV, and formula volume. In this paper, we have validated these mathematical equations so that they can be implemented in clinical practice. Each of 16 patients receiving a nasogastric tube had 50 mL of water followed by 100 mL of dietary formula (Osmolite HN, Abbott Laboratories, Columbus, OH) infused into the stomach. After mixing, gastric content was aspirated for the first Brix value (BV) measurement by refractometry. Then, 50 mL of water was infused into the stomach and a second BV was measured. The procedure of infusion of dietary formula (100 mL) and then water (50 mL) was repeated and followed by subsequent BV measurement. The same procedure was performed in an in vitro experiment. Formula concentration, GRV, and formula volume were calculated from the derived mathematical equations. The formula concentrations, GRVs, and formula volumes calculated by using refractometry and the mathematical equations were close to the true values obtained from both in vivo and in vitro validation experiments. Using this method, measurement of the BV of gastric contents is simple, reproducible, and inexpensive. Refractometry and the derived mathematical equations may be used to measure formula concentration, GRV, and formula volume, and also to serve as a tool for monitoring the gastric contents of patients receiving nasogastric feeding.

  9. On the Measurements of Particles Smaller than 20 μM by Global Rainbow Refractometry

    NASA Astrophysics Data System (ADS)

    Saengkaew, S.; Bonin, D.; Gréh, G.

    2007-06-01

    The measurement of the thermo-chemical characteristics of particles under evaporation or cooling is a challenge. Among others techniques, Global Rainbow Refractometry (GRR) is potentially applicable to a large variety of realistic media. This paper is focused on refractive index measurements of particles smaller than 20 μm which are especially important to extract droplet temperature in spray combustion.

  10. Brix refractometry in serum as a measure of failure of passive transfer compared to measured immunoglobulin G and total protein by refractometry in serum from dairy calves.

    PubMed

    Hernandez, D; Nydam, D V; Godden, S M; Bristol, L S; Kryzer, A; Ranum, J; Schaefer, D

    2016-05-01

    A series of trials were conducted to evaluate Brix refractometry (Brix %) for the assessment of failure of passive transfer (FPT) in dairy calves compared to: (1) serum IgG (reference standard) when measured by radial immunodiffusion (RID) or a turbidometric immunoassay (TIA), and (2) serum total protein refractometry (STP). For the serum samples tested with TIA, STP, and Brix % (n = 310; Holstein calves), the median concentrations were 21.3 g/L IgG, 58 g/L STP, and 9.2%, respectively. For the serum samples tested with RID, STP and Brix % (n = 112; Jersey calves), the mean concentrations were 38 g/L IgG, 68 g/L STP, and 10.2%, respectively. For samples tested with only Brix % and STP (n = 265; Holstein calves), median STP and Brix % were 50 g/L STP and 8.5%, respectively. Correlations between Brix % and RID, and between Brix % and TIA were equal (r = 0.79, respectively). Brix % and STP were positively correlated (r = 0.99). Brix % estimated serum IgG concentrations determined by TIA and RID (r(2) = 0.63, 0.62, respectively). When FPT was defined as serum IgG < 10 g/L, Brix % ≤ 8.5% showed optimal sensitivity (100%) and specificity (89.2%) to predict FPT. At the same IgG cut-point, an STP value of ≤ 52 g/L showed a similar sensitivity (100%) and specificity (80.4%) to predict FPT. Brix refractometry predicted successful transfer of passive immunity in dairy calves, but further evaluation as a diagnostic tool for the diagnosis of FPT is warranted. Copyright © 2016. Published by Elsevier Ltd.

  11. [Comparative measurement of urine specific gravity: reagent strips, refractometry and hydrometry].

    PubMed

    Costa, Christian Elías; Bettendorff, Carolina; Bupo, Sol; Ayuso, Sandra; Vallejo, Graciela

    2010-06-01

    The urine specific gravity is commonly used in clinical practice to measure the renal concentration/dilution ability. Measurement can be performed by three methods: hydrometry, refractometry and reagent strips. To assess the accuracy of different methods to measure urine specific gravity. We analyzed 156 consecutive urine samples of pediatric patients during April and May 2007. Urine specific gravity was measured by hydrometry (UD), refractometry (RE) and reagent strips (TR), simultaneously. Urine osmolarity was considered as the gold standard and was measured by freezing point depression. Correlation between different methods was calculated by simple linear regression. A positive and acceptable correlation was found with osmolarity for the RE as for the UD (r= 0.81 and r= 0.86, respectively). The reagent strips presented low correlation (r= 0.46). Also, we found good correlation between measurements obtained by UD and RE (r= 0.89). Measurements obtained by TR, however, had bad correlation when compared to UD (r= 0.46). Higher values of specific gravity were observed when measured with RE with respect to UD. Reagent strips are not reliable for measuring urine specific gravity and should not be used as an usual test. However, hydrometry and refractometry are acceptable alternatives for measuring urine specific gravity, as long as the same method is used for follow-up.

  12. The use of 1H-NMR spectroscopy and refractometry for investigation of the distribution of nonelectrolytes of N-alcohol series between human red blood cells and extracellular medium.

    PubMed

    Kucherenko, Y U; Moiseev, V A

    2000-01-01

    Comparative analysis of 1H NMR spectroscopy and refractometry with respect to their application for investigating the distribution of nonelectrolytes of n-alcohol series (ethanol, 1,2-propanediol, glycerol) and polyethylene glycols (PEGs) with molecular masses of 400, 600, 1500 between human erythrocytes and extracellular medium was performed. The distribution coefficients (Q) for solutions of ethanol, 1,2-propanediol, glycerol, PEG-400, PEG-600 and PEG-1500 were obtained. The Q values decreased with the increase in the nonelectrolyte molecular mass from 1.23+/-0.12 for ethanol to 0.40+/-0.08 for PEG-1500 (1H NMR spectroscopy) and from 2.6+/-0.12 for ethanol to 0.23+/-0.03 for PEG-1500 (refractometry). It was shown that 1H-NMR high-resolution spectroscopy ensures more precise determination of Q values for nonelectrolytes with low molecular masses; for PEGs with high molecular masses, the accuracy of Q value calculation by this method was about 20%. On the contrary, refractometry can be used for investigating substances with high molecular masses; the error of Q value determination for solution of low-refractive substances, such as ethanol, may be more than 50%.

  13. Refractometry for quality control of anesthetic drug mixtures.

    PubMed

    Stabenow, Jennifer M; Maske, Mindy L; Vogler, George A

    2006-07-01

    Injectable anesthetic drugs used in rodents are often mixed and further diluted to increase the convenience and accuracy of dosing. We evaluated clinical refractometry as a simple and rapid method of quality control and mixing error detection of rodent anesthetic or analgesic mixtures. Dilutions of ketamine, xylazine, acepromazine, and buprenorphine were prepared with reagent-grade water to produce at least 4 concentration levels. The refraction of each concentration then was measured with a clinical refractometer and plotted against the percentage of stock concentration. The resulting graphs were linear and could be used to determine the concentration of single-drug dilutions or to predict the refraction of drug mixtures. We conclude that refractometry can be used to assess the concentration of dilutions of single drugs and can verify the mixing accuracy of drug combinations when the components of the mixture are known and fall within the detection range of the instrument.

  14. Analysis of Vaginal Microbicide Film Hydration Kinetics by Quantitative Imaging Refractometry

    PubMed Central

    Rinehart, Matthew; Grab, Sheila; Rohan, Lisa; Katz, David; Wax, Adam

    2014-01-01

    We have developed a quantitative imaging refractometry technique, based on holographic phase microscopy, as a tool for investigating microscopic structural changes in water-soluble polymeric materials. Here we apply the approach to analyze the structural degradation of vaginal topical microbicide films due to water uptake. We implemented transmission imaging of 1-mm diameter film samples loaded into a flow chamber with a 1.5×2 mm field of view. After water was flooded into the chamber, interference images were captured and analyzed to obtain high resolution maps of the local refractive index and subsequently the volume fraction and mass density of film material at each spatial location. Here, we compare the hydration dynamics of a panel of films with varying thicknesses and polymer compositions, demonstrating that quantitative imaging refractometry can be an effective tool for evaluating and characterizing the performance of candidate microbicide film designs for anti-HIV drug delivery. PMID:24736376

  15. Analysis of vaginal microbicide film hydration kinetics by quantitative imaging refractometry.

    PubMed

    Rinehart, Matthew; Grab, Sheila; Rohan, Lisa; Katz, David; Wax, Adam

    2014-01-01

    We have developed a quantitative imaging refractometry technique, based on holographic phase microscopy, as a tool for investigating microscopic structural changes in water-soluble polymeric materials. Here we apply the approach to analyze the structural degradation of vaginal topical microbicide films due to water uptake. We implemented transmission imaging of 1-mm diameter film samples loaded into a flow chamber with a 1.5×2 mm field of view. After water was flooded into the chamber, interference images were captured and analyzed to obtain high resolution maps of the local refractive index and subsequently the volume fraction and mass density of film material at each spatial location. Here, we compare the hydration dynamics of a panel of films with varying thicknesses and polymer compositions, demonstrating that quantitative imaging refractometry can be an effective tool for evaluating and characterizing the performance of candidate microbicide film designs for anti-HIV drug delivery.

  16. Rediscovery and Revival of Analytical Refractometry for Protein Determination: Recombining Simplicity With Accuracy in the Digital Era.

    PubMed

    Anderle, Heinz; Weber, Alfred

    2016-03-01

    Among "vintage" methods of protein determination, quantitative analytical refractometry has received far less attention than well-established pharmacopoeial techniques based on protein nitrogen content, such as Dumas combustion (1831) and Kjeldahl digestion (1883). Protein determination by quantitative refractometry dates back to 1903 and has been extensively investigated and characterized in the following 30 years, but has since vanished into a few niche applications that may not require the degree of accuracy and precision essential for pharmaceutical analysis. However, because high-resolution and precision digital refractometers have replaced manual instruments, reducing time and resource consumption, the method appears particularly attractive from an economic, ergonomic, and environmental viewpoint. The sample solution can be measured without dilution or other preparation procedures than the separation of the protein-free matrix by ultrafiltration, which might even be omitted for a constant matrix and excipient composition. Copyright © 2016 American Pharmacists Association®. Published by Elsevier Inc. All rights reserved.

  17. [Comparisons of manual and automatic refractometry with subjective results].

    PubMed

    Wübbolt, I S; von Alven, S; Hülssner, O; Erb, C

    2006-11-01

    Refractometry is very important in everyday clinical practice. The aim of this study is to compare the precision of three objective methods of refractometry with subjective dioptometry (Phoropter). The objective methods with the smallest deviation to subjective refractometry results are evaluated. The objective methods/instruments used were retinoscopy, Prism Refractometer PR 60 (Rodenstock) and Auto Refractometer RM-A 7000 (Topcon). The results of monocular dioptometry (sphere, cylinder and axis) of each objective method were compared to the results of the subjective method. The examination was carried out on 178 eyes, which were divided into 3 age-related groups: 6 - 12 years (103 eyes), 13 - 18 years (38 eyes) and older than 18 years (37 eyes). All measurements were made in cycloplegia. The smallest standard deviation of the measurement error was found for the Auto Refractometer RM-A 7000. Both the PR 60 and retinoscopy had a clearly higher standard deviation. Furthermore, the RM-A 7000 showed in three and retinoscopy in four of the nine comparisons a significant bias in the measurement error. The Auto Refractometer provides measurements with the smallest deviation compared to the subjective method. Here it has to be taken into account that the measurements for the sphere have an average deviation of + 0.2 dpt. In comparison to retinoscopy the examination of children with the RM-A 7000 is difficult. An advantage of the Auto Refractometer is the fast and easy handling, so that measurements can be performed by medical staff.

  18. Using differential scanning calorimetry, laser refractometry, electrical conductivity and spectrophotometry for discrimination of different types of Bulgarian honey

    NASA Astrophysics Data System (ADS)

    Vlaeva, I.; Nikolova, K.; Bodurov, I.; Marudova, M.; Tsankova, D.; Lekova, S.; Viraneva, A.; Yovcheva, T.

    2017-01-01

    The potential of several physical methods for investigation of the botanical origin of honey has been discussed. Samples from the three most prevalent types of honey in Bulgaria (acacia, linden and honeydew) have been used. They have been examined by laser refractometry, UV, VIS and FTIR spectroscopy, electric conductivity measurement and differential scanning calorimetry. The purpose of this study was to reveal the physical characterizations of honeys from different flora produced in Bulgaria and to identify honeys with a high apitherapy potential for future studies.

  19. [Peripheral refraction and retinal contour in children with myopia by results of refractometry and partial coherence interferometry].

    PubMed

    Tarutta, E P; Milash, S V; Tarasova, N A; Romanova, L I; Markosian, G A; Epishina, M V

    2014-01-01

    To determine the posterior pole contour of the eye based on the relative peripheral refractive error and relative eye length. A parallel study was performed, which enrolled 38 children (76 eyes) with myopia from -1.25 to -10.82 diopters. The patients underwent peripheral refraction assessment with WR-5100K Binocular Auto Refractometer ("Grand Seiko", Japan) and partial coherence tomography with IOLMaster ("Carl Zeiss", Germany) for the relative eye length in areas located 15 and 30 degrees nasal and temporal from the central fovea along the horizontal meridian. In general, refractometry and interferometry showed high coincidence of defocus signs and values for the areas located 15 and 30 degrees nasal as well as 15 degrees temporal from the fovea. However, in 41% of patients defocus signs determined by the two methods mismatched in one or more areas. Most of the mismatch cases were mild myopia. We suppose that such a mismatch is caused by optical peculiarities of the anterior eye segment that have an impact on refractometry results.

  20. Indirect absorption spectroscopy using quantum cascade lasers: mid-infrared refractometry and photothermal spectroscopy.

    PubMed

    Pfeifer, Marcel; Ruf, Alexander; Fischer, Peer

    2013-11-04

    We record vibrational spectra with two indirect schemes that depend on the real part of the index of refraction: mid-infrared refractometry and photothermal spectroscopy. In the former, a quantum cascade laser (QCL) spot is imaged to determine the angles of total internal reflection, which yields the absorption line via a beam profile analysis. In the photothermal measurements, a tunable QCL excites vibrational resonances of a molecular monolayer, which heats the surrounding medium and changes its refractive index. This is observed with a probe laser in the visible. Sub-monolayer sensitivities are demonstrated.

  1. Change in refractive index of muscle tissue during laser-induced interstitial thermotherapy.

    PubMed

    Chen, Na; Chen, Meimei; Liu, Shupeng; Guo, Qiang; Chen, Zhenyi; Wang, Tingyun

    2014-01-01

    This paper presents a long-period fiber-grating (LPG) based Michelson interferometric refractometry to monitor the change in refractive index of porcine muscle during laser-induced interstitial thermotherapy (LITT). As the wavelength of RI interferometer alters with the change in refractive index around the probe, the LPG based refractometry is combined with LITT system to measure the change in refractive index of porcine muscle when irradiated by laser. The experimental results show the denaturation of tissue alters the refractive index significantly and the LPG sensor can be applied to monitor the tissue state during the LITT.

  2. The reliability and validity of hand-held refractometry water content measures of hydrogel lenses.

    PubMed

    Nichols, Jason J; Mitchell, G Lynn; Good, Gregory W

    2003-06-01

    To investigate within- and between-examiner reliability and validity of hand-held refractometry water content measures of hydrogel lenses. Nineteen lenses of various nominal water contents were examined by two examiners on two occasions separated by 1 hour. An Atago N2 hand-held refractometer was used for all water content measures. Lenses were presented in a random order to each examiner by a third party, and examiners were masked to any potential lens identifiers. Intraclass correlation coefficients (ICC), 95% limits of agreement, and Wilcoxon signed rank test were used to characterize the within- and between-examiner reliability and validity of lens water content measures. Within-examiner reliability was excellent (ICC, 0.97; 95% limits of agreement, -3.6% to +5.7%), and the inter-visit mean difference of 1.1 +/- 2.4% was not biased (p = 0.08). Between-examiner reliability was also excellent (ICC, 0.98; 95% limits of agreement, -4.1% to +3.9%). The mean difference between examiners was -0.1 +/- 2.1% (p = 0.83). The mean difference between the nominally reported water content and our water content measures was -2.1 +/- 1.7% (p < 0.001); the 95% limits of agreement for this difference were -5.4% to +1.1%. There is good reliability within and between examiners in measuring water content of hydrogel lenses. However, with our sample of lenses, examiners tended to overestimate the nominal water content of hydrogel lenses. As discussed, this bias may be associated with the Brix scale used in refractometry and is material dependent. Therefore, investigators may need to account for bias when measuring hydrogel lens water content via hand-held refractometry.

  3. Monitoring of temperature-mediated phase transitions of adipose tissue by combined optical coherence tomography and Abbe refractometry.

    PubMed

    Yanina, Irina Y; Popov, Alexey P; Bykov, Alexander V; Meglinski, Igor V; Tuchin, Valery V

    2018-01-01

    Observation of temperature-mediated phase transitions between lipid components of the adipose tissues has been performed by combined use of the Abbe refractometry and optical coherence tomography. The phase transitions of the lipid components were clearly observed in the range of temperatures from 24°C to 60°C, and assessed by quantitatively monitoring the changes of the refractive index of 1- to 2-mm-thick porcine fat tissue slices. The developed approach has a great potential as an alternative method for obtaining accurate information on the processes occurring during thermal lipolysis. (2018) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE).

  4. The density of the cell sap and endoplasm of Nitellopsis and Chara

    NASA Technical Reports Server (NTRS)

    Wayne, R.; Staves, M. P.

    1991-01-01

    We measured the densities of the cell sap, endoplasm and cell wall of Nitellopsis obtusa and Chara corallina using interference microscopy, refractometry, immersion refractometry, equilibrium sedimentation and chemical microanalysis techniques. These values are important for the determination of many rheological properties of the cytoplasm as well as for understanding buoyancy regulation, dispersal mechanisms and how cells respond to gravity. The average densities of the cell sap, endoplasm and cell wall are 1,006.9, 1,016.7 and 1,371 kg m-3 for Nitellopsis and 1,005.0, 1,013.9, and 1,355.3 kg m-3 for Chara.

  5. REFRACTOMETRY AS A TOOL IN DIABETIC STUDIES

    PubMed Central

    Kavitha, S.; Murthy, V.R.

    2006-01-01

    The refractive index as well as molar refraction, is the true index of purity of substance and plays a vital role in solution chemistry. A small addition of a foreign substance either in solid state of liquid form is going to effect the refractive index. As such the variation of refractive indices in pure glucose solution as a function of concentration is studied in detail and this principle is extended to the study of the refractive indices of urine solution of diabetic patients. The refractive indices are measured by spectrometry and abbe refractometry. A detailed study of variation of refractive indices of urine samples containing different sugar concentrations, of patients of different age groups revealed that the increase in refractive index follows a linear scale and can be explained by the equation, n=no [l+0.00251og (a s)1/4] [l+0.031og0.011C]. These study provided an opportunity to project refractometry as an effective tool in diagnosing the diabetic level of a patient by making use of a simple calibration curve of increment in refractive index ‘Δn, as a function of level of the disease. PMID:22557211

  6. Education-Related Parameters in High Myopia: Adults versus School Children.

    PubMed

    Jonas, Jost B; Xu, Liang; Wang, Ya Xing; Bi, Hong Sheng; Wu, Jian Feng; Jiang, Wen Jun; Nangia, Vinay; Sinha, Ajit; Zhu, Dan; Tao, Yong; Guo, Yin; You, Qi Sheng; Wu, Li Juan; Tao, Li Xin; Guo, Xiu Hua; Ohno-Matsui, Kyoko; Panda-Jonas, Songhomitra

    2016-01-01

    Since high myopia in the younger generation may differ etiologically from high myopia in older generations, we examined whether education-related parameters differ between high myopia in today´s school children and high pathological myopia in today´s elderly generation. The investigation included the adult populations of the population-based Beijing Eye Study (BES) (3468 adults;mean age:64.6±9.8years;range:50-93years) and Central India Eye and Medical Study (CIEMS) (4711 adults;age:49.±13.2years;range:30-100years), and the children and teenager populations of the Shandong Children Eye Study (SCES) (6026 children;age:9.7±3.3years;range:4-18years;cycloplegic refractometry), Gobi Desert Children Eye Study (1565;age:11.9±3.5years;range:6-21 years;cycloplegic refractometry), Beijing Pediatric Eye Study (681 children;age:7.7±1.6years;range:5-13 years;non-cycloplegic refractometry,calculation of axial length to corneal curvature radius ratio), Beijing Children Eye Study (15066 children;age:13.2±3.4years;range:7-18years;non-cycloplegic refractometry), Beijing High School Teenager Eye Study (4677 children;age:16.9±0.7years;range:16-18years;non-cycloplegic refractometry). In the BES and CIEMS, educational level did not differ significantly between, or was significantly lower in the highly myopic group (myopic refractive error ≥6 diopters) than in the non-highly myopic group. In all non-adult study populations, higher prevalence of high myopia was significantly associated with higher degree of education related parameters such as attendance of high-level schools, and more time spent for indoors near work versus time spent outdoors. Comparing associations of old or genetic high myopia in adults with new or acquired high myopia in school children revealed that education-related parameters did not show a clear association with old or genetic high myopia, while in contrast, new high myopia showed strong associations with education. It confirms previous studies that the two forms of high myopia not only differed in age of onset, but also in associations with education as well. The data support the notion of two types of high myopia. Future studies may assess whether the risk of pathologic myopic maculopathy and high myopia associated open-angle glaucoma differs between both types of high myopia.

  7. Bifocal optical coherenc refractometry of turbid media.

    PubMed

    Alexandrov, Sergey A; Zvyagin, Andrei V; Silva, K K M B Dilusha; Sampson, David D

    2003-01-15

    We propose and demonstrate a novel technique, which we term bifocal optical coherence refractometry, for the rapid determination of the refractive index of a turbid medium. The technique is based on the simultaneous creation of two closely spaced confocal gates in a sample. The optical path-length difference between the gates is measured by means of low-coherence interferometry and used to determine the refractive index. We present experimental results for the refractive indices of milk solutions and of human skin in vivo. As the axial scan rate determines the acquisition time, which is potentially of the order of tens of milliseconds, the technique has potential for in vivo refractive-index measurements of turbid biological media under dynamic conditions.

  8. Topography and refractometry of nanostructures using spatial light interference microscopy.

    PubMed

    Wang, Zhuo; Chun, Ik Su; Li, Xiuling; Ong, Zhun-Yong; Pop, Eric; Millet, Larry; Gillette, Martha; Popescu, Gabriel

    2010-01-15

    Spatial light interference microscopy (SLIM) is a novel method developed in our laboratory that provides quantitative phase images of transparent structures with a 0.3 nm spatial and 0.03 nm temporal accuracy owing to the white light illumination and its common path interferometric geometry. We exploit these features and demonstrate SLIM's ability to perform topography at a single atomic layer in graphene. Further, using a decoupling procedure that we developed for cylindrical structures, we extract the axially averaged refractive index of semiconductor nanotubes and a neurite of a live hippocampal neuron in culture. We believe that this study will set the basis for novel high-throughput topography and refractometry of man-made and biological nanostructures.

  9. Measurement of the refractive index of soft contact lenses during wear.

    PubMed

    Varikooty, Jalaiah; Keir, Nancy; Woods, Craig A; Fonn, Desmond

    2010-01-01

    To determine whether the refractive index (RI) of a soft contact lens can be evaluated using refractometry while the lens remains on the eye and to compare this with more traditional ex vivo RI measurements. A slitlamp apparatus was modified to incorporate a customized Atago hand refractometer. With a double-masked study design, nine adapted symptomatic soft contact lens wearers wore a contact lens in each eye (lotrafilcon B and etafilcon A) in a randomized order. In vivo RI was determined from the relative Brix scale measurements immediately after lens insertion and after 1 and 10 hr of lens wear. Ex vivo refractometry was performed after 10 hr of lens wear for comparison. Means +/- standard errors of the means are reported. In vivo RI values at baseline were 1.422 +/- 0.0004 (lotrafilcon B) and 1.405 +/- 0.0021 (etafilcon A); after 1 hr of lens wear, values were 1.423 +/- 0.0006 and 1.408 +/- 0.0007, respectively; and after 10 hr of lens wear, values were 1.424 +/- 0.0004 and 1.411 +/- 0.0010, respectively. Ex vivo RI values at the end of the 10 hr wearing period were 1.424 +/- 0.0003 (lotrafilcon B) and 1.412 +/- 0.0017 (etafilcon A). The change in in vivo RI across the day was statistically significant for the etafilcon A lens (repeated-measures analysis of variance, P<0.01) but not for the lotrafilcon B lens (P>0.05). This novel adaptation of refractometry was able to measure the RI of soft contact lenses during wear (without lens removal). End of day RI measurements using in vivo and ex vivo refractometry were comparable with each other. Future work is required to determine whether this in vivo method can improve our understanding of the relationships between soft contact lens RI, hydration, on-eye lens performance, and symptomology.

  10. THE STRUCTURE AND CONCENTRATION OF SOLIDS IN PHOTORECEPTOR CELLS STUDIED BY REFRACTOMETRY AND INTERFERENCE MICROSCOPY

    PubMed Central

    Sidman, Richard L.

    1957-01-01

    Fragments of freshly obtained retinas of several vertebrate species were studied by refractometry, with reference to the structure of the rods and cones. The findings allowed a reassessment of previous descriptions based mainly on fixed material. The refractometric method was used also to measure the refractice indices and to calculate the concentrations of solids and water in the various cell segments. The main quantitative data were confirmed by interference microscopy. When examined by the method of refractometry the outer segments of freshly prepared retinal rods appear homogeneous. Within a few minutes a single eccentric longitudinal fiber appears, and transverse striations may develop. These changes are attributed to imbibition of water and swelling in structures normally too small for detection by light microscopy. The central "core" of outer segments and the chromophobic disc between outer and inner segments appear to be artifacts resulting from shrinkage during dehydration. The fresh outer segments of cones, and the inner segments of rods and cones also are described and illustrated. The volumes, refractive indices, concentrations of solids, and wet and dry weights of various segments of the photoreceptor cells were tabulated. Rod outer segments of the different species vary more than 100-fold in volume and mass but all have concentrations of solids of 40 to 43 per cent. Cone outer segments contain only about 30 per cent solids. The myoids, paraboloids, and ellipsoids of the inner segments likewise have characteristic refractive indices and concentrations of solids. Some of the limitations and particular virtues of refractometry as a method for quantitative analysis of living cells are discussed in comparison with more conventional biochemical techniques. Also the shapes and refractive indices of the various segments of photoreceptor cells are considered in relation to the absorption and transmission of light. The Stiles-Crawford effect can be accounted for on the basis of the structure of cone cells. PMID:13416308

  11. Education-Related Parameters in High Myopia: Adults versus School Children

    PubMed Central

    Xu, Liang; Wang, Ya Xing; Bi, Hong Sheng; Wu, Jian Feng; Jiang, Wen Jun; Nangia, Vinay; Sinha, Ajit; Zhu, Dan; Tao, Yong; Guo, Yin; You, Qi Sheng; Wu, Li Juan; Tao, Li Xin; Guo, Xiu Hua; Ohno-Matsui, Kyoko; Panda-Jonas, Songhomitra

    2016-01-01

    Purpose Since high myopia in the younger generation may differ etiologically from high myopia in older generations, we examined whether education-related parameters differ between high myopia in today´s school children and high pathological myopia in today´s elderly generation. Methods The investigation included the adult populations of the population-based Beijing Eye Study (BES) (3468 adults;mean age:64.6±9.8years;range:50–93years) and Central India Eye and Medical Study (CIEMS) (4711 adults;age:49.±13.2years;range:30–100years), and the children and teenager populations of the Shandong Children Eye Study (SCES) (6026 children;age:9.7±3.3years;range:4–18years;cycloplegic refractometry), Gobi Desert Children Eye Study (1565;age:11.9±3.5years;range:6–21 years;cycloplegic refractometry), Beijing Pediatric Eye Study (681 children;age:7.7±1.6years;range:5–13 years;non-cycloplegic refractometry,calculation of axial length to corneal curvature radius ratio), Beijing Children Eye Study (15066 children;age:13.2±3.4years;range:7–18years;non-cycloplegic refractometry), Beijing High School Teenager Eye Study (4677 children;age:16.9±0.7years;range:16–18years;non-cycloplegic refractometry). Results In the BES and CIEMS, educational level did not differ significantly between, or was significantly lower in the highly myopic group (myopic refractive error ≥6 diopters) than in the non-highly myopic group. In all non-adult study populations, higher prevalence of high myopia was significantly associated with higher degree of education related parameters such as attendance of high-level schools, and more time spent for indoors near work versus time spent outdoors. Conclusions Comparing associations of old or genetic high myopia in adults with new or acquired high myopia in school children revealed that education-related parameters did not show a clear association with old or genetic high myopia, while in contrast, new high myopia showed strong associations with education. It confirms previous studies that the two forms of high myopia not only differed in age of onset, but also in associations with education as well. The data support the notion of two types of high myopia. Future studies may assess whether the risk of pathologic myopic maculopathy and high myopia associated open-angle glaucoma differs between both types of high myopia. PMID:27152764

  12. Systematic Review and Meta-Analysis of Diagnostic Accuracy of Serum Refractometry and Brix Refractometry for the Diagnosis of Inadequate Transfer of Passive Immunity in Calves.

    PubMed

    Buczinski, S; Gicquel, E; Fecteau, G; Takwoingi, Y; Chigerwe, M; Vandeweerd, J M

    2018-01-01

    Transfer of passive immunity in calves can be assessed by direct measurement of immunoglobulin G (IgG) by methods such as radial immunodiffusion (RID) or turbidimetric immunoassay (TIA). IgG can also be measured indirectly by methods such as serum refractometry (REF) or Brix refractometry (BRIX). To determine the accuracy of REF and BRIX for assessment of inadequate transfer of passive immunity (ITPI) in calves. Systematic review and meta-analysis of diagnostic accuracy studies. Databases (PubMed and CAB Abstract, Searchable Proceedings of Animal Science) and Google Scholar were searched for relevant studies. Studies were eligible if the accuracy (sensitivity and specificity) of REF or BRIX was determined using direct measurement of IgG by RID or turbidimetry as the reference standard. The study population included calves <14 days old that were fed with natural colostrum (colostrum replacement products were excluded). Quality assessment was performed by the QUADAS-2 tool. Hierarchical models were used for meta-analysis. From 1,291 references identified, 13 studies of 3,788 calves were included. Of these, 11 studies evaluated REF and 5 studies evaluated BRIX. The median (range) prevalence of ITPI (defined as calves with IgG <10 g/L by RID or TIA) was 21% (1.3-56%). Risk of bias and applicability concerns were generally low or unclear. For REF, summary estimates were obtained for 2 different cutoffs: 5.2 g/dL (6 studies) and 5.5 g/dL (5 studies). For the 5.2 g/dL cutoff, the summary sensitivity (95% CI) and specificity (95% CI) were 76.1% (63.8-85.2%) and 89.3% (82.3-93.7%), and 88.2% (80.2-93.3%) and 77.9% (74.5-81.0%) for the 5.5 g/dL cutoff. Due to the low number of studies using the same cutoffs, summary estimates could not be obtained for BRIX. Despite their widespread use on dairy farms, evidence about the optimal strategy for using refractometry, including the optimal cutoff, are sparse (especially for BRIX). When using REF to rule out ITPI in herds, the 5.5 g/dL cutoff may be used whereas for ruling in ITPI, the 5.2 g/dL cutoff may be used. Copyright © 2017 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine.

  13. Topography and refractometry of nanostructures using spatial light interference microscopy (SLIM)

    PubMed Central

    Wang, Zhuo; Chun, Ik Su; Li, Xiuling; Ong, Zhun-Yong; Pop, Eric; Millet, Larry; Gillette, Martha; Popescu, Gabriel

    2010-01-01

    Spatial Light Interference Microscopy (SLIM) is a novel method developed in our laboratory that provides quantitative phase images of transparent structures with 0.3 nm spatial and 0.03 nm temporal accuracy owing to the white light illumination and its common path interferometric geometry. We exploit these features and demonstrate SLIM's ability to perform topography at a single atomic layer in graphene. Further, using a decoupling procedure that we developed for cylindrical structures, we extract the axially-averaged refractive index of semiconductor nanotubes and a neurite of a live hippocampal neuron in culture. We believe that this study will set the basis for novel high-throughput topography and refractometry of man-made and biological nanostructures. PMID:20081970

  14. Angular filter refractometry analysis using simulated annealing.

    PubMed

    Angland, P; Haberberger, D; Ivancic, S T; Froula, D H

    2017-10-01

    Angular filter refractometry (AFR) is a novel technique used to characterize the density profiles of laser-produced, long-scale-length plasmas [Haberberger et al., Phys. Plasmas 21, 056304 (2014)]. A new method of analysis for AFR images was developed using an annealing algorithm to iteratively converge upon a solution. A synthetic AFR image is constructed by a user-defined density profile described by eight parameters, and the algorithm systematically alters the parameters until the comparison is optimized. The optimization and statistical uncertainty calculation is based on the minimization of the χ 2 test statistic. The algorithm was successfully applied to experimental data of plasma expanding from a flat, laser-irradiated target, resulting in an average uncertainty in the density profile of 5%-20% in the region of interest.

  15. Ultrastructure Processing of Macromolecular Materials

    DTIC Science & Technology

    1993-02-11

    Segudovic, R. Vukovic, V. Kuresevic and W.J. MacKnight) "Solution Properties of Poly(fluorostyrene-co-chlorostyrene) Copolymers. I. Light Scattering, Differential Refractometry and Viscometry" (in press).

  16. Use of supernatant refractive index and supernatant hemoglobin concentration to assess residual glycerol concentration in cryopreserved red blood cells.

    PubMed

    Wong, Kenneth A; Nsier, Nada; Acker, Jason P

    2009-10-01

    Red blood cells (RBCs) cryopreserved in glycerol must be deglycerolized prior to transfusion. The adequacy of glycerol removal is commonly assessed by measurement of the refractive index (RI) of the supernatant fluid. However, the presence of free hemoglobin in the supernatant falsely increases the RI and may lead to discard of units that have an acceptable residual glycerol concentration. We performed an analysis of the diagnostic accuracy of 3 methods for residual glycerol measurement - refractometry, osmometry, and a glycerol assay kit. Residual glycerol measurement using these methods was performed on 12 deglycerolized, citrate-phosphate-dextrose (CPD)/saline-adenine-glucose-mannitol (SAGM) leukoreduced RBCs. A calculation that estimates the glycerol concentration based on the refractive index and supernatant hemoglobin concentration was developed and ensures that units with an elevated RI due to the presence of hemoglobin are not discarded if their residual glycerol concentration was <1.0% (w/v). Osmometry was an accurate method for estimating residual glycerol concentration. Refractometry overestimated the residual glycerol concentration due to the interference from hemoglobin. However, when supernatant hemoglobin values were measured and used in the calculation for glycerol concentration, refractometry accurately estimated the residual glycerol concentration. The residual glycerol concentration of cryopreserved, deglycerolized CPD/SAGM RBCs can be accurately estimated using the supernatant refractive index and an equation that accounts for the supernatant hemoglobin concentration.

  17. Topography and refractometry of sperm cells using spatial light interference microscopy

    NASA Astrophysics Data System (ADS)

    Liu, Lina; Kandel, Mikhail E.; Rubessa, Marcello; Schreiber, Sierra; Wheeler, Mathew B.; Popescu, Gabriel

    2018-02-01

    Characterization of spermatozoon viability is a common test in treating infertility. Recently, it has been shown that label-free, phase-sensitive imaging can provide a valuable alternative for this type of assay. We employ spatial light interference microscopy (SLIM) to perform high-accuracy single-cell phase imaging and decouple the average thickness and refractive index information for the population. This procedure was enabled by quantitative-phase imaging cells on media of two different refractive indices and using a numerical tool to remove the curvature from the cell tails. This way, we achieved ensemble averaging of topography and refractometry of 100 cells in each of the two groups. The results show that the thickness profile of the cell tail goes down to 150 nm and the refractive index can reach values of 1.6 close to the head.

  18. Comparison of pH and refractometry index with calcium concentrations in preparturient mammary gland secretions of mares.

    PubMed

    Korosue, Kenji; Murase, Harutaka; Sato, Fumio; Ishimaru, Mutsuki; Kotoyori, Yasumitsu; Tsujimura, Koji; Nambo, Yasuo

    2013-01-15

    To test the usefulness of measuring pH and refractometry index, compared with measuring calcium carbonate concentration, of preparturient mammary gland secretions for predicting parturition in mares. Evaluation study. 27 pregnant Thoroughbred mares. Preparturient mammary gland secretion samples were obtained once or twice daily 10 days prior to foaling until parturition. The samples were analyzed for calcium carbonate concentration with a water hardness kit (151 samples), pH with pH test paper (222 samples), and refractometry index with a Brix refractometer (214 samples). The sensitivity, specificity, and positive and negative predictive values for each test were calculated for evaluation of predicting parturition. The PPV within 72 hours and the NPV within 24 hours for calcium carbonate concentration determination (standard value set to 400 μg/g) were 93.8% and 98.3%, respectively. The PPV within 72 hours and the NPV within 24 hours for the pH test (standard value set at 6.4) were 97.9% and 99.4%, respectively. The PPV within 72 hours and the NPV within 24 hours for the Brix test (standard value set to 20%) were 73.2% and 96.5%, respectively. Results suggested that the pH test with the standard value set at a pH of 6.4 would be useful in the management of preparturient mares by predicting when mares are not ready to foal. This was accomplished with equal effectiveness of measuring calcium carbonate concentration with a water hardness kit.

  19. Dipstick measurements of urine specific gravity are unreliable.

    PubMed

    de Buys Roessingh, A S; Drukker, A; Guignard, J P

    2001-08-01

    To evaluate the reliability of dipstick measurements of urine specific gravity (U-SG). Fresh urine specimens were tested for urine pH and osmolality (U-pH, U-Osm) by a pH meter and an osmometer, and for U-SG by three different methods (refractometry, automatic readout of a dipstick (Clinitek-50), and (visual) change of colour of the dipstick). The correlations between the visual U-SG dipstick measurements and U-SG determined by a refractometer and the comparison of Clinitek((R))-50 dipstick U-SG measurements with U-Osm were less than optimal, showing very wide scatter of values. Only the U-SG refractometer values and U-Osm had a good linear correlation. The tested dipstick was unreliable for the bedside determination of U-SG, even after correction for U-pH, as recommended by the manufacturer. Among the bedside determinations, only refractometry gives reliable U-SG results. Dipstick U-SG measurements should be abandoned.

  20. Topography and refractometry of sperm cells using spatial light interference microscopy.

    PubMed

    Liu, Lina; Kandel, Mikhail E; Rubessa, Marcello; Schreiber, Sierra; Wheeler, Mathew B; Popescu, Gabriel

    2018-02-01

    Characterization of spermatozoon viability is a common test in treating infertility. Recently, it has been shown that label-free, phase-sensitive imaging can provide a valuable alternative for this type of assay. We employ spatial light interference microscopy (SLIM) to perform high-accuracy single-cell phase imaging and decouple the average thickness and refractive index information for the population. This procedure was enabled by quantitative-phase imaging cells on media of two different refractive indices and using a numerical tool to remove the curvature from the cell tails. This way, we achieved ensemble averaging of topography and refractometry of 100 cells in each of the two groups. The results show that the thickness profile of the cell tail goes down to 150 nm and the refractive index can reach values of 1.6 close to the head. (2018) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE).

  1. Gas refractometry based on an all-fiber spatial optical filter.

    PubMed

    Silva, Susana; Coelho, L; André, R M; Frazão, O

    2012-08-15

    A spatial optical filter based on splice misalignment between optical fibers with different diameters is proposed for gas refractometry. The sensing head is formed by a 2 mm long optical fiber with 50 μm diameter that is spliced with a strong misalignment between two single-mode fibers (SMF28) and interrogated in transmission. The misalignment causes a Fabry-Perot behavior along the reduced-size fiber and depending on the lead-out SMF28 position, it is possible to obtain different spectral responses, namely, bandpass or band-rejection filters. It is shown that the spatial filter device is highly sensitive to refractive index changes on a nitrogen environment by means of the gas pressure variation. A maximum sensitivity of -1390 nm/RIU for the bandpass filter was achieved. Both devices have shown similar temperature responses with an average sensitivity of 25.7 pm/°C.

  2. Spectroscopic Sleuthing. An Introduction to Forensic Science.

    ERIC Educational Resources Information Center

    Zdravkovich, Vera; Cunniff, Patricia A.

    1991-01-01

    Described is a program in which students learn about spectroscopy and instrumentation to solve a chemical forensic mystery. Infrared and nuclear magnetic resonance (NMR) spectroscopy, refractometry, and chromatographic techniques were used. An example of a mystery case is included. (KR)

  3. Continuous nasogastric tube feeding: monitoring by combined use of refractometry and traditional gastric residual volumes.

    PubMed

    Chang, W-K; McClave, S-A; Chao, Y-C

    2004-02-01

    Traditional use of gastric residual volumes (GRVs) is insensitive and cannot distinguish retained enteral formula from the large volume of endogenous secretions. We designed this prospective study to determine whether refractometry and Brix value (BV) measurements could be used to monitor gastric emptying and tolerance in patients receiving continuous enteral feeding. Thirty-six patients on continuous nasogastric tube feeding were divided into two groups; patients with lower GRVs (<75 ml) in Group 1, patients with higher GRVs (>75 ml) in Group 2. Upon entry, all gastric contents were aspirated, the volume was recorded (Asp GRV), BV measurements were made by refractometry, and then the contents were reinstilled but diluted with 30 ml additional water. Finally, a small amount was reaspirated and repeat BV measurements were made. Three hours later, the entire procedure was repeated a second time. The BV ratio, calculated (Cal) GRV, and volume of formula remaining were calculated by derived equations. Mean BV ratios were significantly higher for those patients in Group 2 compared to those in Group 1. All but one of the 22 patients (95%) in Group 1 had a volume of formula remaining in the stomach estimated on both measurements to be less than the hourly infusion rate (all these patients had BV ratios <70%). In contrast, six of the 14 patients in Group 2 (43%) on both measurements were estimated to have volumes of formula remaining that were greater than the hourly infusion rate (all these patients had BV ratios >70%). Three of the Group 2 patients (21%) whose initial measurement showed evidence for retention of formula, improved on repeat follow-up measurement assuring adequate gastric emptying. The remaining five patients from Group 2 (35%) had a volume of formula remaining that was less than the hourly infusion rate on both measurements. The pattern of Asp GRVs and serial pre- and post-dilution BVs failed to differentiate these patients in Group 2 with potential emptying problems from those with sufficient gastric emptying. Refractometry and measurement of the BV may improve the clinical utilization of GRVs, by its ability to identify the component of formula within gastric contents and track changes in that component related to gastric emptying.

  4. Estimate of serum immunoglobulin G concentration using refractometry with or without caprylic acid fractionation.

    PubMed

    Morrill, K M; Polo, J; Lago, A; Campbell, J; Quigley, J; Tyler, H

    2013-07-01

    Objectives of this study were to develop a rapid calf-side test to determine serum IgG concentrations using caprylic acid (CA) fractionation, followed by refractometry of the IgG-rich supernatant and compare the accuracy of this method with results obtained using refractometry using raw serum. Serum samples (n=200) were obtained from 1-d-old calves, frozen (-20°C), and shipped to the laboratory. Samples were allowed to thaw for 1h at room temperature. Fractionation with CA was conducted by adding 1mL of serum to a tube containing 45, 60, or 75µL of CA and 0.5, 1.0, or 1.5mL of 0.06 M acetic acid. The tube contents were mixed well, allowed to react for 1 min, and then centrifuged at 3,300 × g for 0, 10, or 20 min at 25°C. The %Brix and refractive index of the fractionated supernatant were determined using a digital refractometer. Nonfractionated serum was analyzed for %Brix (BRn), refractive index (nDn), and IgG concentration by radial immunodiffusion. The mean serum IgG concentration was 19.0 mg/mL [standard deviation (SD)=9.7], with a range of 3.5 to 47.0 mg/mL. The mean serum BRn was 8.6 (SD=0.91), with a range of 6.8 to 11.0. The mean serum nDn was 1.34566 (SD=0.00140), with a range of 1.34300 to 1.34930. Serum nDn was positively correlated with IgG concentration (correlation coefficient=0.86; n=185). Fractionated samples treated with 1mL 0.6 M acetic acid and 60µL of CA and not centrifuged before analysis resulted in a strong relationship between the refractive index of the fractionated supernatant and IgG (correlation coefficient=0.80; n=45). Regression was used to determine cut points indicative of 10, 12, and 14 mg of IgG/mL to determine the sensitivity and specificity of refractometry to identify failure of passive transfer (serum IgG <10 mg/mL at 24 h old). The nDn were 1.34414, 1.34448, and 1.34480 to predict 10, 12, and 14 mg of IgG/mL of serum, respectively. The BRn cut points were 7.6, 7.8, and 8.0, respectively. The nDn cut points of 1.34448 and 1.34480 resulted in similar specificities (82.9%), whereas the 1.34414 cut point had a specificity of 60.0%. The BRn cut point of 7.6 and 7.8%Brix resulted in a similar percentage of correctly classified samples (89.7 and 90.8%, respectively); however, the 7.8% Brix cut point resulted in fewer false positives. These results suggest that Brix refractometry of nonfractionated calf serum provides a strong estimate of IgG concentration and 7.8% Brix may be used as the cut point to identify failure of passive transfer in 1-d-old calves. Copyright © 2013 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  5. Equivalences between refractive index and equilibrium water content of conventional and silicone hydrogel soft contact lenses from automated and manual refractometry.

    PubMed

    González-Méijome, José M; López-Alemany, Antonio; Lira, Madalena; Almeida, José B; Oliveira, M Elisabete C D Real; Parafita, Manuel A

    2007-01-01

    The purpose of the present study was to develop mathematical relationships that allow obtaining equilibrium water content and refractive index of conventional and silicone hydrogel soft contact lenses from refractive index measures obtained with automated refractometry or equilibrium water content measures derived from manual refractometry, respectively. Twelve HEMA-based hydrogels of different hydration and four siloxane-based polymers were assayed. A manual refractometer and a digital refractometer were used. Polynomial models obtained from the sucrose curves of equilibrium water content against refractive index and vice-versa were used either considering the whole range of sucrose concentrations (16-100% equilibrium water content) or a range confined to the equilibrium water content of current soft contact lenses (approximately 20-80% equilibrium water content). Values of equilibrium water content measured with the Atago N-2E and those derived from the refractive index measurement with CLR 12-70 by the applications of sucrose-based models displayed a strong linear correlation (r2 = 0.978). The same correlations were obtained when the models are applied to obtain refractive index values from the Atago N-2E and compared with those (values) given by the CLR 12-70 (r2 = 0.978). No significantly different results are obtained between models derived from the whole range of the sucrose solution or the model limited to the normal range of soft contact lens hydration. Present results will have implications for future experimental and clinical research regarding normal hydration and dehydration experiments with hydrogel polymers, and particularly in the field of contact lenses. 2006 Wiley Periodicals, Inc.

  6. Clinical performance evaluation of total protein measurement by digital refractometry and characterization of non-protein solute interferences.

    PubMed

    Hunsaker, Joshua J H; Wyness, Sara P; Snow, Taylor M; Genzen, Jonathan R

    2016-12-01

    Refractometric methods to measure total protein (TP) in serum and plasma specimens have been replaced by automated biuret methods in virtually all routine clinical testing. A subset of laboratories, however, still report using refractometry to measure TP in conjunction with serum protein electrophoresis. The objective of this study was therefore to conduct a modern performance evaluation of a digital refractometer for TP measurement. Performance evaluation of a MISCO Palm Abbe™ digital refractometer was conducted through device familiarization, carryover, precision, accuracy, linearity, analytical sensitivity, analytical specificity, and reference interval verification. Comparison assays included a manual refractometer and an automated biuret assay. Carryover risk was eliminated using a demineralized distilled water (ddH 2 O) wash step. Precision studies demonstrated overall imprecision of 2.2% CV (low TP pool) and 0.5% CV (high TP pool). Accuracy studies demonstrated correlation to both manual refractometry and the biuret method. An overall positive bias (+5.0%) was observed versus the biuret method. On average, outlier specimens had an increased triglyceride concentration. Linearity was verified using mixed dilutions of: a) low and high concentration patient pools, or b) albumin-spiked ddH 2 O and high concentration patient pool. Decreased recovery was observed using ddH 2 O dilutions at low TP concentrations. Significant interference was detected at high concentrations of glucose (>267 mg/dL) and triglycerides (>580 mg/dL). Current laboratory reference intervals for TP were verified. Performance characteristics of this digital refractometer were validated in a clinical laboratory setting. Biuret method remains the preferred assay for TP measurement in routine clinical analyses.

  7. Evaluation of five commercially available assays and measurement of serum total protein concentration via refractometry for the diagnosis of failure of passive transfer of immunity in foals.

    PubMed

    Davis, Rachel; Giguère, Steeve

    2005-11-15

    To determine and compare sensitivity, specificity, accuracy, and predictive values of measurement of serum total protein concentration by refractometry as well as 5 commercially available kits for the diagnosis of failure of passive transfer (FPT) of immunity in foals. Prospective study. 65 foals with various medical problems and 35 clinically normal foals. IgG concentration in serum was assessed by use of zinc sulfate turbidity (assay C), glutaraldehyde coagulation (assay D), 2 semiquantitative immunoassays (assays F and G), and a quantitative immunoassay (assay H). Serum total protein concentration was assessed by refractometry. Radial immunodiffusion (assays A and B) was used as the reference method. For detection of IgG < 400 mg/dL, sensitivity of assay H (100%) was not significantly different from that of assays C, E, and G (88.9%). Specificity of assays H (96.0%) and G (95.8%) was significantly higher than that of assays C (79.4%) and E (78.1 %). For detection of IgG < 800 mg/dL, sensitivities of assays H (976%), D (92.9%), C (81.0%), and G (81.0%) were significantly higher than that of assay F (52.4%). Specificity of assays F (100%), G (94.7%), and H (82.8%) was significantly higher than that of assays C (56.9%) and D (58.6%). Serum total protein concentration < or = 4.5 g/dL was suggestive of FPT, whereas values > or = 6.0 g/dL indicated adequate IgG concentrations. Most assays were adequate as initial screening tests. However, their use as a definitive test would result in unnecessary treatment of foals with adequate IgG concentrations.

  8. [Evaluation of immunoglobulin G concentration in colostrum of mares by ELISA, refractometry and colostrometry].

    PubMed

    Venner, Monica; Markus, R G; Strutzberg-Minder, K; Nogai, K; Beyerbach, M; Klug, E

    2008-01-01

    In 360 samples of colostrum and 36 samples of blood of warmblood mares, the concentration of immunoglobulin G (IgG) was evaluated in the post partal period with an ELISA and the results were compared to values obtained with 2 field methods--refractometry and colostrometry. A significant correlation (p < 0.0001) was determined between ELISA and colostrometry (r = +0.88) and between ELISA and refractometry (r = +0.93). So both field-methods seem suitable for evaluation of the colostral IgG-concentration in mares. Further the kinetic of the IgG concentration in colostrum, the volume of colostrum and the total amount of IgG was measured in the 12 hours post partum (p.p.) in each half udder of 36 mares of different parity. Immediately p.p. primiparous mares have a greater mean concentration of IgG (68 mg/ml) than multiparous mares (51 mg/ml). However, multiparous mares have a mean colostral volume of 1020 ml whereas, in primiparous mares, a mean volume of 527 ml was determined within the first three hours p.p. As a result of this the total amount of IgG was lower in primiparous (31.5 g) than in multiparous mares (48.5 g). A significant decrease of IgG concentration was measured in multiparous mares in the 1.5 hours following partum versus 3 hours in primiparous mares. The mean IgG concentration in the blood serum of the 36 mares immediately p.p. was 13.4 +/- 3.6 mg/ml. No significant correlation was observed between values of IgG concentration in the blood and in the colostrum of the mares.

  9. Correlation of serum IgG concentration in foals and refractometry index of the dam's pre- and post-parturient colostrums: an assessment for failure of passive transfer in foals.

    PubMed

    Korosue, Kenji; Murase, Harutaka; Sato, Fumio; Ishimaru, Mutsuki; Kotoyori, Yasumitsu; Nambo, Yasuo

    2012-11-01

    The object of this study was to evaluate the usefulness of measuring the differences in the values of the serum total protein (DVSTP) concentration of foals and the refractometry index (DVRI) of the milk of dams before and after nursing of the colostrum for assessing failure of passive transfer (FPT) in foals. Serum samples from 31 foals were collected before the first nursing and other 1 to 6 times between 4 and 24 hr after birth. Paired colostrum and milk samples were collected from 14 of their dams at the same time. Serum samples were analyzed for IgG concentration using a single radial immunodiffusion (SRID) test (98 samples) and total protein concentration using a temperature-compensating refractometer (98 samples). Colostrum and milk samples were analyzed for refractometry index (RI) using a Brix refractometer (71 samples). DVSTP concentration and DVRI were significantly correlated with serum IgG concentration. The negative predictive values (NPVs) of DVSTP concentration for detecting serum IgG concentrations<400 mg/dl and<800 mg/dl were 98.2% and 91.3% when the cutoff value is set to 0.4 mg/dl and 0.8 mg/dl, respectively. Furthermore, the NPVs of DVRI for detecting serum IgG concentrations<400 mg/dl and<800 mg/dl were 97.3% and 96.3% when the cutoff value is set to 6% and 10%, respectively. The results suggest that measurement of DVRI is useful in assessing FPT as an initial "stall-side" screening test, because it is easy, inexpensive to perform and allows for rapid interpretation.

  10. The Determination of the Concentrations of Sugar Solutions by Laser Refractometry.

    ERIC Educational Resources Information Center

    Hughes, Elvin, Jr.; And Others

    1988-01-01

    Presents an easily performed experiment to determine sucrose concentrations using a laser and a hollow glass prism. The experiment is suggested for high school, freshman college, and instrumental analysis classes. Notes an Erlenmeyer flask can be used instead of a prism. (MVL)

  11. Notes on Experiments.

    ERIC Educational Resources Information Center

    Physics Education, 1984

    1984-01-01

    Describes (1) oil slick interference rings in the laboratory; (2) cracking of glass by impact; (3) multipurpose prism for refractometry and light path demonstrations; and (4) determination of liquid densities and volumes of solid bodies by the reaction force on a vessel. Procedures used and equipment needed are discussed. (JN)

  12. Optical diagnostic suite (schlieren, interferometry, and grid image refractometry) on OMEGA EP using a 10-ps, 263-nm probe beam.

    PubMed

    Froula, D H; Boni, R; Bedzyk, M; Craxton, R S; Ehrne, F; Ivancic, S; Jungquist, R; Shoup, M J; Theobald, W; Weiner, D; Kugland, N L; Rushford, M C

    2012-10-01

    A 10-ps, 263-nm (4ω) laser is being built to probe plasmas produced on the OMEGA EP [J. H. Kelly, L. J. Waxer, V. Bagnoud, I. A. Begishev, J. Bromage, B. E. Kruschwitz, T. E. Kessler, S. J. Loucks, D. N. Maywar, R. L. McCrory et al., J. Phys. IV France 133, 75-80 (2006)]. A suite of optical diagnostics (schlieren, interferometry, and grid image refractometry) has been designed to diagnose and characterize a wide variety of plasmas. Light scattered by the probe beam is collected by an f/4 catadioptric telescope and a transport system is designed to image with a near-diffraction-limited resolution (~1 - μm full width at half maximum) over a 5-mm field of view to a diagnostic table. The transport system provides a contrast greater than 1 : 10(4) with respect to all wavelengths outside of the 263 ± 2 nm measurement range.

  13. Dipstick measurements of urine specific gravity are unreliable

    PubMed Central

    Roessingh, A; Drukker, A; Guignard, J

    2001-01-01

    AIM—To evaluate the reliability of dipstick measurements of urine specific gravity (U-SG).
METHODS—Fresh urine specimens were tested for urine pH and osmolality (U-pH, U-Osm) by a pH meter and an osmometer, and for U-SG by three different methods (refractometry, automatic readout of a dipstick (Clinitek-50), and (visual) change of colour of the dipstick).
RESULTS—The correlations between the visual U-SG dipstick measurements and U-SG determined by a refractometer and the comparison of Clinitek®-50 dipstick U-SG measurements with U-Osm were less than optimal, showing very wide scatter of values. Only the U-SG refractometer values and U-Osm had a good linear correlation. The tested dipstick was unreliable for the bedside determination of U-SG, even after correction for U-pH, as recommended by the manufacturer.
CONCLUSIONS—Among the bedside determinations, only refractometry gives reliable U-SG results. Dipstick U-SG measurements should be abandoned.

 PMID:11466191

  14. Novel differential refractometry study of the enzymatic degradation kinetics of poly(ethylene oxide)-b-poly(epsilon-caprolactone) particles dispersed in water.

    PubMed

    Lam, HiuFung; Gong, Xiangjun; Wu, Chi

    2007-02-22

    A poly(ethylene oxide)-b-poly(epsilon-caprolactone) (PEO-b-PCL) diblock copolymer was micronized into small micelle-like particles (approximately 80 nm) via dialysis-induced microphase inversion. The enzymatic biodegradation of the PCL portion of these particles in water was in situ investigated inside a recently developed novel differential refractometer. Using this refractometry method, we were able to monitor the real-time biodegradation via the refractive index change (Deltan) of the dispersion because Deltan is directly proportional to the particle mass concentration. We found that the degradation rate is proportional to either the polymer or enzyme concentration. Our results directly support previous speculation on the basis of the light-scattering data that the biodegradation follows the first-order kinetics for a given enzyme concentration. This study not only leads to a better understanding of the enzymatic biodegradation of PCL, but also demonstrates a novel, rapid, noninvasive, and convenient way to test the degradability of polymers.

  15. Optical diagnostic suite (schlieren, interferometry, and grid image refractometry) on OMEGA EP using a 10-ps, 263-nm probe beama)

    NASA Astrophysics Data System (ADS)

    Froula, D. H.; Boni, R.; Bedzyk, M.; Craxton, R. S.; Ehrne, F.; Ivancic, S.; Jungquist, R.; Shoup, M. J.; Theobald, W.; Weiner, D.; Kugland, N. L.; Rushford, M. C.

    2012-10-01

    A 10-ps, 263-nm (4ω) laser is being built to probe plasmas produced on the OMEGA EP [J. H. Kelly, L. J. Waxer, V. Bagnoud, I. A. Begishev, J. Bromage, B. E. Kruschwitz, T. E. Kessler, S. J. Loucks, D. N. Maywar, R. L. McCrory et al., J. Phys. IV France 133, 75-80 (2006)], 10.1051/jp4:2006133015. A suite of optical diagnostics (schlieren, interferometry, and grid image refractometry) has been designed to diagnose and characterize a wide variety of plasmas. Light scattered by the probe beam is collected by an f/4 catadioptric telescope and a transport system is designed to image with a near-diffraction-limited resolution (˜1 - μm full width at half maximum) over a 5-mm field of view to a diagnostic table. The transport system provides a contrast greater than 1 : 104 with respect to all wavelengths outside of the 263 ± 2 nm measurement range.

  16. Live cell refractometry using microfluidic devices.

    PubMed

    Lue, Niyom; Popescu, Gabriel; Ikeda, Takahiro; Dasari, Ramachandra R; Badizadegan, Kamran; Feld, Michael S

    2006-09-15

    Using Hilbert phase microscopy for extracting quantitative phase images, we measured the average refractive index associated with live cells in culture. To decouple the contributions to the phase signal from the cell refractive index and thickness, we confined the cells in microchannels. The results are confirmed by comparison with measurements of spherical cells in suspension.

  17. Use of refractometry and colorimetry as field methods to rapidly assess antimalarial drug quality.

    PubMed

    Green, Michael D; Nettey, Henry; Villalva Rojas, Ofelia; Pamanivong, Chansapha; Khounsaknalath, Lamphet; Grande Ortiz, Miguel; Newton, Paul N; Fernández, Facundo M; Vongsack, Latsamy; Manolin, Ot

    2007-01-04

    The proliferation of counterfeit and poor-quality drugs is a major public health problem; especially in developing countries lacking adequate resources to effectively monitor their prevalence. Simple and affordable field methods provide a practical means of rapidly monitoring drug quality in circumstances where more advanced techniques are not available. Therefore, we have evaluated refractometry, colorimetry and a technique combining both processes as simple and accurate field assays to rapidly test the quality of the commonly available antimalarial drugs; artesunate, chloroquine, quinine, and sulfadoxine. Method bias, sensitivity, specificity and accuracy relative to high-performance liquid chromatographic (HPLC) analysis of drugs collected in the Lao PDR were assessed for each technique. The HPLC method for each drug was evaluated in terms of assay variability and accuracy. The accuracy of the combined method ranged from 0.96 to 1.00 for artesunate tablets, chloroquine injectables, quinine capsules, and sulfadoxine tablets while the accuracy was 0.78 for enterically coated chloroquine tablets. These techniques provide a generally accurate, yet simple and affordable means to assess drug quality in resource-poor settings.

  18. A heterodyne refractometer for air index of refraction and air density measurements

    NASA Astrophysics Data System (ADS)

    Fang, H.; Picard, A.; Juncar, P.

    2002-04-01

    We briefly describe a heterodyne refractometer developed at the BIPM in collaboration with the BNM/INM conservatory. The heart of the refractometer, a double Fabry-Perot interferometer, is placed inside the balance case of a very sensitive 1 kg mass comparator, the FB2 balance. Comparisons between methods using refractometry and the NPL revised Edlén formulas, carried out for a period of nine months, yielded a difference in air index of refraction of 4×10-8 with a standard deviation of 1×10-8. The variation of air index of refraction was about 1.5×10-5 during the study. Precise determinations of the short-term and long-term stability of the Fabry-Perot cavity, made of Zerodur, were also achieved. For monitoring air density, results obtained with the refractometry method were compared with those deduced from two other methods: the CIPM formula for the density of moist air and the use of buoyancy artifacts. The response characteristics for the three determinations were comparable and the agreement among the air density determinations was within 1×10-5 kg m-3.

  19. On the suitability of refractometry for the analysis of glucose in blood-derived fluids.

    PubMed

    Zirk, K; Poetzschke, H

    2004-07-01

    Refractometry is the determination of the optical refractive index of a substance or a mixture of substances. It is a very sensitive method for the detection and quantification of dissolved analytes, but it is incapable of distinguishing between different analytes. The aim of this investigation was to determine the principle suitability of refractometry for the quantification of glucose (blood sugar) in blood and various blood fluids which can readily be obtained for medical diagnosis, in particular blood plasma, blood serum, and their ultrafiltrates. After the oral intake of freshly dissolved alpha-glucose, the in vivo blood contents of the alpha and beta anomers of glucose were found to be in an at least approximate equilibrium at all times. This observation is a prerequisite for a refractometrical determination of glucose due to the fact that both molecule forms have different refractive index increments. An assessment of the glucose content in untreated blood fluids was not possible, since no suitable relationship to the refractive index was found, most probably due to the influence of the many other substances present in blood on this parameter. However, after removal of certain macromolecules by ultrafiltration, value pairs showed a high level of correlation, providing the nominal molecular weight limit (cut-off) of the ultrafilter used possessed a maximum of 300 kDa. Besides macromolecules, the osmolality of the fluids undergoing measurement also proved to be a considerable interfering factor, particularly when values were outside the normal physiological range between 285 and 293 mmol/L. If a clinical application of this method is to be contemplated it is imperative (1) that blood cells are separated and removed, (2) that macromolecules present in plasma or serum are removed, e.g. by ultrafiltration, and (3) that beyond the results presented the influence of all small molecules other than glucose on the overall refractive index be determined and included in the calculation of analysis results.

  20. Assessment of hydration status of elite young male soccer players with different methods and new approach method of substitute urine strip.

    PubMed

    Ersoy, Nesli; Ersoy, Gulgun; Kutlu, Mehmet

    2016-01-01

    The purpose of the study is to determine and compare the hydration status with different methods and determine fluid intake, dehydration percentages and sweat rate of 26 young male soccer players (15 ± 1.2 years) before an important competition. More specifically, the study aims at validating the urine strip and advising the players to use it as an easy and practical method. Measurements of urine analysis were taken from the urine sample of the participants before breakfast and conducted for 3 consecutive days before the competition. Hydration status was assessed through analysis of urine color, urine specific gravity (USG) (laboratory, strip, refractometry), and osmolality. The players' dehydration percentages and sweat ratio were calculated. The average values for all samples were 3 ± 1 for color, and 1.021 ± 4 g/cm(3) for USG (laboratory), and 1.021 ± 3 g/cm(3) for USG (strip), and 1.021 ± 4 for USG (refractometry), and 903 ± 133 mOsm/kg for osmolality. USG (strip) was highly correlated with USG (laboratory), USG (refractometry) (r = 0.8; P < 0.01) and osmolality (r = 0.7; P < 0.01), and moderately correlated with urine color (r = 0.4; P < 0.05). The mean dehydration percentage and sweat rate of the soccer players were observed as 0.5 % and 582.3 ± 232.0 mL/h, respectively. We found that youth soccer players are under a slight risk of dehydration under moderate weather conditions. As indicated by the research results, determination of hydration status of athletes must be taken into account more carefully under moderate and hot weather conditions. In addition, hydration methods were compatible with one another as measured in this study.

  1. A refractometry-based glucose analysis of body fluids.

    PubMed

    Zirk, Kai; Poetzschke, Harald

    2007-05-01

    In principle, refractometry appears to be a suitable method for the measurement of glucose concentrations in body fluids (such as blood and the intercellular fluid), even though the refractive index of the measured samples, as an additive property, is not specific. But, if certain conditions are fulfilled, the glucose content can be calculated using the refractive index in combination with values from a further measurement. This study describes the determination of the glucose content using refractometry in human blood serum derivates, which were selected - due to their ready availability - to be used as a model for interstitial fluid. Refractometry of body fluids requires the elimination of disturbing components from the measurement sample. First of all, a homogenous fluid (i.e. consisting of one phase) is required, so that all cells and components in suspension need to be separated out. Furthermore, certain dissolved macromolecular components which are known to disturb the measurement process must also be removed. In human serum samples which had been ultrafiltrated with a range of ultrafilters of different pore sizes, a comparative evaluation showed that only ultrafiltration through a filter with a separation limit of between 3 and 30kDa resulted in maximal reduction of the refractive index (compared to native serum), whereas ultrafilters with greater separation limits did not. The total content of osmotically active solutes (the tonicity) also exerts a clear influence. However, exemplary measurements in blood plasma fluid from one volunteer showed that the electrical conductivity is (without an additive component) directly proportional to the osmolality: physiological changes in the state of body hydration (hyperhydration and dehydration) do not lead to any considerable changes in the relation between ionised and uncharged solute particles, but instead result in a sufficiently clear dilution or concentration of the blood fluid's low molecular components. This finding allows the use of the--technically easy to measure--electrical conductivity as a measure for the tonicity of the measurement samples. Using measurements of these two parameters--refractive index and electrical conductivity--in blood serum obtained from a healthy volunteer, a two-dimensional calibration function (calibration matrix) for the assessment of the glucose content of ultrafiltrated human blood serum was constructed, and the measurement of blood glucose levels in non-diabetic (four females and four males) volunteers in comparison to a reference method was evaluated showing (as a proof of concept) a linear association. Assessment of the inaccuracy of these measurements made with the described measuring devices and methods showed a deviation from the reference values of less than 10%. An estimation of the maximum possible error showed relative deviations (maximum measurement uncertainties) of up to 20%.

  2. Relation Between Near Work and Myopia Progression in Student Population

    PubMed Central

    Muhamedagic, Lejla; Muhamedagic, Belma; Halilovic, Emina Alimanovic; Halimic, Jasmina Alajbegovic; Stankovic, Aleksa; Muracevic, Bedrana

    2014-01-01

    Aim To determine relation between near work and myopia progression in student population. Causes of myopia occurrence are not sufficiently explained. Methods This retrospective-prospective, descriptive research included 100 students with verified myopia up to -3 Dsph. Ophthalmological examination and measurement diopter-hours variable (Dh) were done twice, in the period from January 2011 until January 2012. Results A multivariate regression analysis of impact on the difference of distance visual acuity without correction to the right and left eye and difference of automatic computer refractometry in cycloplegia of both eyes indicates that, diopter-hours variable (Dh) had statistically significant impact on increase of distance visual acuity difference (right eye OR: I measurement–Dh 1.489, II measurement–Dh 1.544, p<0.05; left eye OR: I measurement–Dh 1.602, II measurement–Dh 1.538, p<0.05) and automatic computer refractometry in cycloplegia (right eye OR: I measurement 1.361, II measurement 1.493, p<0.05; left eye OR: I measurement 0.931, II measurement 1.019, p<0.05) during both measurements. Conclusion Near work cause the increase of myopia. This research opened a perspective for other researches on the impact of near work on myopia. PMID:24944532

  3. Application of rainbow refractometry for measurement of droplets with solid inclusions

    NASA Astrophysics Data System (ADS)

    Li, Can; Wu, Xue-cheng; Cao, Jian-zheng; Chen, Ling-hong; Gréhan, Gerard; Cen, Ke-fa

    2018-01-01

    Characterization of droplets with solid inclusions is of great research interest and has wide industrial applications. Reported here is a theoretical and experimental investigation of the measurement of droplets with solid inclusions using rainbow refractometry. A rainbow extinction model of a droplet with solid inclusions was deduced based on Beer-Lambert's Law. It takes into account the volume concentration, relative size, scattering efficiency of the solid inclusion, and liquid refractive index. An acoustic levitation system for a single droplet and a global rainbow instrumentation system for spray were integrated to study the effect of the H2O-CaCO3 suspension droplets on the rainbow signal and the measured parameters. The results showed that the rainbow encountered unusual disturbances, introduced by the solid inclusions, but its overall structure was not destroyed. Discoveries also included that for volume concentrations of 2.5% or less the CaCO3 particles with diameters below 4 μm had little effect on the measured parameters of the host droplet. The extinction characteristic was also analyzed. The rainbow extinction model failed to quantity the volume concentration of CaCO3, but succeeded in its qualitative analysis.

  4. Evaluation of passive transfer in captive greater kudu (Tragelaphus strepsiceros).

    PubMed

    Hammond, Elizabeth E; Fiorello, Christine V

    2011-12-01

    Failure of passive transfer (FPT) in captive greater kudu (Tragelaphus strepsiceros) calves can lead to increased morbidity and mortality. In this retrospective study, serum samples from neonatal kudu calves were tested for immunoglobulin using different tests validated for domestic ruminants, including measurement of gamma globulin (GG) measured by protein electrophoresis, total solids (TS) measured by calibrated refractometry, total protein (TP) and globulins measured by colorimetry, gamma glutamyltransferase (GGT), and the zinc sulfate turbidity test (ZSTT). In a logistic regression model, TP, TS, globulins, and the natural log transform of GGT were the only significant parameters associated with FPT. Various historic parameters related to the dam, as well as calf weight, sex, glucose, and packed cell volume, were not significant. Based on the results, FPT in greater kudu is defined as GG of < 0.5 g/dl, a value lower than that in domestic cattle. TS measured by refractometry has an 80% sensitivity and a 100% specificity for FPT in greater kudu. With FPT defined as GG < 0.5 g/dl, kudu calves with a TS < 4.8 g/dl and a negative ZSTT have an increased probability of requiring medical intervention and additional diagnostics may be warranted.

  5. Mapping surface tension induced menisci with application to tensiometry and refractometry.

    PubMed

    Mishra, Avanish; Kulkarni, Varun; Khor, Jian-Wei; Wereley, Steve

    2015-07-28

    In this work, we discuss an optical method for measuring surface tension induced menisci. The principle of measurement is based upon the change in the background pattern produced by the curvature of the meniscus acting as a lens. We measure the meniscus profile over an inclined glass plate and utilize the measured meniscus for estimation of surface tension and refractive index.

  6. A simple method to measure critical angles for high-sensitivity differential refractometry.

    PubMed

    Zilio, S C

    2012-01-16

    A total internal reflection-based differencial refractometer, capable of measuring the real and imaginary parts of the complex refractive index in real time, is presented. The device takes advantage of the phase difference acquired by s- and p-polarized light to generate an easily detectable minimum at the reflected profile. The method allows to sensitively measuring transparent and turbid liquid samples.

  7. Technical note: Evaluation of digital refractometers to estimate serum immunoglobulin G concentration and passive transfer in Jersey calves.

    PubMed

    McCracken, M M; Morrill, K M; Fordyce, A L; Tyler, H D

    2017-10-01

    Previous data have demonstrated that refractometers can be used to estimate serum IgG, and that a cut-point of 7.8% Brix should be used to identify failure of passive transfer (FPT) in 1-d-old Holstein calves. The objective of the present study was to validate the use of refractometry to estimate serum IgG concentrations and evaluate FPT in Jersey calves. Blood samples (n = 97) were obtained from 1- to 3-d-old Jersey calves and centrifuged at 3,300 × g for 20 min at 25°C. Serum was analyzed for % Brix, total protein (TP), and refractive index (nD) using a Sper Scientific Digital Refractometer (model #300036, Sper Scientific, Scottsdale, AZ) within 12 h of sampling. Samples were then frozen and later analyzed in the laboratory for IgG by radial immunodiffusion. The mean serum IgG concentration for all calves was 23.7 mg/mL (SD = 12.5), with a range of 2.3 to 65.5 mg/mL. Mean serum % Brix was 8.9 (SD = 1.1; range 6.5 to 12.0). Serum % Brix was moderately correlated with IgG concentration (r = 0.77). Total protein and IgG were moderately correlated (r = 0.790). Regression was used to determine cut-points for approximately 10, 12, and 14 mg of IgG/mL and to determine the sensitivity and specificity of refractometry to identify FPT (serum IgG <10 mg/mL at 24 h of life). Brix cut-points analyzed were 7.1, 7.3, and 7.6%; TP cut-points were 4.6, 5.0, and 5.5 g/dL; and nD cut-points were 1.34332, 1.34271, and 1.3448, respectively, for 10, 12, and 14 mg of IgG/mL. The 7.3% Brix and 4.6 g/dL TP cut-points resulted in the greatest percentage of samples being correctly classified. These data suggest that digital refractometry is an acceptable and rapid method to estimate immunoglobulin G in Jersey calf serum. Copyright © 2017 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  8. Quantitative diffusion and swelling kinetic measurements using large-angle interferometric refractometry.

    PubMed

    Saunders, John E; Chen, Hao; Brauer, Chris; Clayton, McGregor; Chen, Weijian; Barnes, Jack A; Loock, Hans-Peter

    2015-12-07

    The uptake and release of sorbates into films and coatings is typically accompanied by changes of the films' refractive index and thickness. We provide a comprehensive model to calculate the concentration of the sorbate from the average refractive index and the film thickness, and validate the model experimentally. The mass fraction of the analyte partitioned into a film is described quantitatively by the Lorentz-Lorenz equation and the Clausius-Mosotti equation. To validate the model, the uptake kinetics of water and other solvents into SU-8 films (d = 40-45 μm) were explored. Large-angle interferometric refractometry measurements can be used to characterize films that are between 15 μm to 150 μm thick and, Fourier analysis, is used to determine independently the thickness, the average refractive index and the refractive index at the film-substrate interface at one-second time intervals. From these values the mass fraction of water in SU-8 was calculated. The kinetics were best described by two independent uptake processes having different rates. Each process followed one-dimensional Fickian diffusion kinetics with diffusion coefficients for water into SU-8 photoresist film of 5.67 × 10(-9) cm(2) s(-1) and 61.2 × 10(-9) cm(2) s(-1).

  9. Phase separation between nucleoid and cytoplasm in Escherichia coli as defined by immersive refractometry.

    PubMed Central

    Valkenburg, J A; Woldringh, C L

    1984-01-01

    The refractive indices of nucleoid and cytoplasm in Escherichia coli were derived theoretically and experimentally. For the theoretical estimates, we made use of the known macromolecular composition of E. coli B/r (G. Churchward and H. Bremer, J. Theor. Biol. 94:651-670, 1982) and of estimates of cell and nucleoid volumes. These were obtained from micrographs of living bacteria made with a confocal scanning light microscope. The theoretical values were calculated, assuming that all DNA occurred in the nucleoid and that all protein and RNA occurred in the cytoplasm. Comparison with experimental refractive index values directly obtained by immersive refractometry showed that, besides its DNA, the nucleoid must contain an additional amount of solids equivalent to 8.6% (wt/vol) protein. With the nucleoid containing 6.8% (wt/vol) DNA and 8.6% (wt/vol) protein and the cytoplasm containing 21% (wt/vol) protein and 4% (wt/vol) RNA, a mass difference is obtained, which accounts for the phase separation observed between the nucleoid and cytoplasm in living cells by phase-contrast microscopy. The decrease in the refractive index of the nucleoid relative to that of the cytoplasm observed upon, for instance, OsO4 fixation was interpreted as being indicative of the loss of protein content in the nucleoid. Images PMID:6389508

  10. A comparison of serum harvesting methods and type of refractometer for determining total solids to estimate failure of passive transfer in calves

    PubMed Central

    Wallace, Melissa M.; Jarvie, Brenna D.; Perkins, Nicole R.

    2006-01-01

    Abstract Monitoring the passive transfer of immunoglobulins from colostrums particularly in noncentrifuged samples can be useful for calf health management programs. The results of total solids refractometry from centrifuge and noncentrifuge harvested sources of serum were highly correlated (R2 = 0.95). Results from a digital and a hand-held refractometer were highly correlated (R2 = 0.96). PMID:16808230

  11. Sweet-sensitive protein from bovine taste buds: isolation and assay.

    PubMed

    Dastoli, F R; Price, S

    1966-11-18

    Using refractometry and ultraviolet-difference spectroscopy to indicate interaction between proteins and coinpounds of low molecular weight, we found a protein fraction in bovine tongue extracts that coinplexes sugars and saccharin. The strengths of the coinzplexes parallel the degrees of sweetness of the compounds, and the effects of pH upon formation of complexes parallel the effects of pH upon sensitivity of taste buds to sweet compounds in vivo.

  12. Refractometry studies of the optical properties of polymer films and the development of polymer coated refractive index sensors

    NASA Astrophysics Data System (ADS)

    Saunders, John Edward

    Sensors for real-time monitoring of environmental contaminants are essential for protecting ecosystems and human health. Refractive index sensing is a non-selective technique that can be used to measure almost any analyte. Miniaturized refractive index sensors, such as silicon-on-insulator (SOI) microring resonators are one possible platform, but require coatings selective to the analytes of interest. A homemade prism refractometer is reported and used to characterize the interactions between polymer films and liquid or vapour-phase analytes. A camera was used to capture both Fresnel reflection and total internal reflection within the prism. For thin-films (d = 10 μm - 100 μm), interference fringes were also observed. Fourier analysis of the interferogram allowed for simultaneous extraction of the average refractive index and film thickness with accuracies of Δn = 1-7 x10-4 and Δd < 3-5%. The refractive indices of 29 common organic solvents as well as aqueous solutions of sodium chloride, sucrose, ethylene glycol, glycerol, and dimethylsulfoxide were measured at λ = 1550 nm. These measurements will be useful for future calibrations of near-infrared refractive index sensors. A mathematical model is presented, where the concentration of analyte adsorbed in a film can be calculated from the refractive index and thickness changes during uptake. This model can be used with Fickian diffusion models to measure the diffusion coefficients through the bulk film and at the film-substrate interface. The diffusion of water and other organic solvents into SU-8 epoxy was explored using refractometry and the diffusion coefficient of water into SU-8 is presented. Exposure of soft baked SU-8 films to acetone, acetonitrile and methanol resulted in rapid delamination. The diffusion of volatile organic compound (VOC) vapours into polydimethylsiloxane and polydimethyl-co-polydiphenylsiloxane polymers was also studied using refractometry. Diffusion and partition coefficients are reported for several analytes. As a model system, polydimethyl-co-diphenylsiloxane films were coated onto SOI microring resonators. After the development of data acquisition software, coated devices were exposed to VOCs and the refractive index response was assessed. More studies with other polymers are required to test the viability of this platform for environmental sensing applications.

  13. Photometric immersion refractometry of bacterial spores.

    PubMed Central

    Gerhardt, P; Beaman, T C; Corner, T R; Greenamyre, J T; Tisa, L S

    1982-01-01

    Photometric immersion refractometry was used to determine the average apparent refractive index (n) of five types of dormant Bacillus spores representing a 600-fold range in moist-heat resistance determined as a D100 value. The n of a spore type increased as the molecular size of various immersion solutes decreased. For comparison of the spore types, the n of the entire spore and of the isolated integument was determined by use of bovine serum albumin, which is excluded from permeating into them. The n of the sporoplast (the structures bounded by the outer pericortex membrane) was determined by use of glucose, which was shown to permeate into the spore only as deeply as the pericortex membrane. Among the various spore types, an exponential increase in the heat resistance correlated with the n of the entire spore and of the sporoplast, but not of the isolated perisporoplast integument. Correlation of the n with the solids content of the entire spore provided a method of experimentally obtaining the refractive index increment (dn/dc), which was constant for the various spore types and enables the calculation of solids and water content from an n. Altogether, the results showed that the total water content is distributed unequally within the dormant spore, with less water in the sporoplast than in the perisporoplast integument, and that the sporoplast becomes more refractile and therefore more dehydrated as the heat resistance becomes greater among the various spore types. PMID:6802796

  14. Comparison of biuret and refractometry methods for the serum total proteins measurement in ruminants.

    PubMed

    Katsoulos, Panagiotis D; Athanasiou, Labrini V; Karatzia, Maria A; Giadinis, Nektarios; Karatzias, Harilaos; Boscos, Constantin; Polizopoulou, Zoe S

    2017-12-01

    Determination of serum total protein concentration is commonly performed by the biuret method. Refractometric measurement is a faster and less expensive alternative but its accuracy has not been determined in ruminants. The purpose of the study was to compare the serum total protein concentrations in cattle, sheep, and goats measured by the biuret method with those obtained by refractometry. Serum total protein concentration was determined in 120 cattle, 67 sheep, and 58 goat blood samples refractometrically and with the biuret method. The data were analyzed with a paired samples t-test, and Passing and Bablok regression equations and Bland and Altman plots were generated. There was a strong linear relationship between the total protein values determined with the refractometer and the biuret method in cattle, sheep, and goats. The statistical accuracy, which represents a bias correction factor that measures the deviation of the best-fit line from the 45° line through the origin, was 90.63% for cattle, 93.05% for sheep, and 91.76% for goats. The mean protein values determined with the refractometer were significantly lower than those measured with the biuret method in cattle and goats (P < .05) but not in sheep (P > .05). The evaluated refractometer was sufficiently accurate for the determination of serum total proteins in cattle, sheep, and goats, although it cannot be used interchangeably with the biuret method. The RIs should be corrected for negative bias based on the created equations. © 2017 American Society for Veterinary Clinical Pathology.

  15. Analysis of Blood Serum by the Method of Refractometry in Antitumor Therapy in Patients with Multiple Myeloma

    NASA Astrophysics Data System (ADS)

    Plotnikova, L. V.; Polyanichko, A. M.; Kobeleva, M. O.; Nikekhin, A. A.; Uspenskaya, M. V.; Kayava, A. V.; Garifullin, A. D.; Voloshin, S. V.

    2018-01-01

    The serum of patients with multiple myeloma was examined by refractometric methods before and after the course of antitumor therapy. It was found that the amount of protein in the serum of patients with multiple myeloma, determined by the value of the serum refractive index, tended to decrease after the course of treatment. The value of the refractive index of blood serum can be used as an additional criterion for assessing the dynamics of changes in blood-serum properties during antitumor therapy.

  16. Eye micromotions influence on an error of Zernike coefficients reconstruction in the one-ray refractometry of an eye

    NASA Astrophysics Data System (ADS)

    Osipova, Irina Y.; Chyzh, Igor H.

    2001-06-01

    The influence of eye jumps on the accuracy of estimation of Zernike coefficients from eye transverse aberration measurements was investigated. By computer modeling the ametropy and astigmatism have been examined. The standard deviation of the wave aberration function was calculated. It was determined that the standard deviation of the wave aberration function achieves the minimum value if the number of scanning points is equal to the number of eye jumps in scanning period. The recommendations for duration of measurement were worked out.

  17. Combined ellipsometry and refractometry technique for characterisation of liquid crystal based nanocomposites.

    PubMed

    Warenghem, Marc; Henninot, Jean François; Blach, Jean François; Buchnev, Oleksandr; Kaczmarek, Malgosia; Stchakovsky, Michel

    2012-03-01

    Spectroscopic ellipsometry is a technique especially well suited to measure the effective optical properties of a composite material. However, as the sample is optically thick and anisotropic, this technique loses its accuracy for two reasons: anisotropy means that two parameters have to be determined (ordinary and extraordinary indices) and optically thick means a large order of interference. In that case, several dielectric functions can emerge out of the fitting procedure with a similar mean square error and no criterion to discriminate the right solution. In this paper, we develop a methodology to overcome that drawback. It combines ellipsometry with refractometry. The same sample is used in a total internal reflection (TIR) setup and in a spectroscopic ellipsometer. The number of parameters to be determined by the fitting procedure is reduced in analysing two spectra, the correct final solution is found by using the TIR results both as initial values for the parameters and as check for the final dielectric function. A prefitting routine is developed to enter the right initial values in the fitting procedure and so to approach the right solution. As an example, this methodology is used to analyse the optical properties of BaTiO(3) nanoparticles embedded in a nematic liquid crystal. Such a methodology can also be used to analyse experimentally the validity of the mixing laws, since ellipsometry gives the effective dielectric function and thus, can be compared to the dielectric function of the components of the mixture, as it is shown on the example of BaTiO(3)/nematic composite.

  18. Comparison of use of an infrared anesthetic gas monitor and refractometry for measurement of anesthetic agent concentrations.

    PubMed

    Ambrisko, Tamas D; Klide, Alan M

    2011-10-01

    To assess agreement between anesthetic agent concentrations measured by use of an infrared anesthetic gas monitor (IAGM) and refractometry. SAMPLE-4 IAGMs of the same type and 1 refractometer. Mixtures of oxygen and isoflurane, sevoflurane, desflurane, or N(2)O were used. Agent volume percent was measured simultaneously with 4 IAGMs and a refractometer at the common gas outlet. Measurements obtained with each of the 4 IAGMs were compared with the corresponding refractometer measurements via the Bland-Altman method. Similarly, Bland-Altman plots were also created with either IAGM or refractometer measurements and desflurane vaporizer dial settings. Bias ± 2 SD for comparisons of IAGM and refractometer measurements was as follows: isoflurane, -0.03 ± 0.18 volume percent; sevoflurane, -0.19 ± 0.23 volume percent; desflurane, 0.43 ± 1.22 volume percent; and N(2)O, -0.21 ± 1.88 volume percent. Bland-Altman plots comparing IAGM and refractometer measurements revealed nonlinear relationships for sevoflurane, desflurane, and N(2)O. Desflurane measurements were notably affected; bias ± limits of agreement (2 SD) were small (0.1 ± 0.22 volume percent) at < 12 volume percent, but both bias and limits of agreement increased at higher concentrations. Because IAGM measurements did not but refractometer measurements did agree with the desflurane vaporizer dial settings, infrared measurement technology was a suspected cause of the nonlinear relationships. Given that the assumption of linearity is a cornerstone of anesthetic monitor calibration, this assumption should be confirmed before anesthetic monitors are used in experiments.

  19. Time-resolved imaging refractometry of microbicidal films using quantitative phase microscopy.

    PubMed

    Rinehart, Matthew T; Drake, Tyler K; Robles, Francisco E; Rohan, Lisa C; Katz, David; Wax, Adam

    2011-12-01

    Quantitative phase microscopy is applied to image temporal changes in the refractive index (RI) distributions of solutions created by microbicidal films undergoing hydration. We present a novel method of using an engineered polydimethylsiloxane structure as a static phase reference to facilitate calibration of the absolute RI across the entire field. We present a study of dynamic structural changes in microbicidal films during hydration and subsequent dissolution. With assumptions about the smoothness of the phase changes induced by these films, we calculate absolute changes in the percentage of film in regions across the field of view.

  20. Live cell refractometry based on non-SPR microparticle sensor.

    PubMed

    Liu, Chang; Chen, David D Y; Yu, Lirong; Luo, Yong

    2013-06-01

    Unlike the nanoparticles with surface plasmon resonance, the optical response of polystyrene microparticles (PSMPs) is insensitive to the chemical components of the surrounding medium under the wavelength-dependent differential interference contrast microscopy. This fact is exploited for the measurement of the refractive index of cytoplasm in this study. PSMPs of 400 nm in diameter were loaded into the cell to contact cytoplasm seamlessly, and the refractive index information of cytoplasm could be extracted by differential interference contrast microscopy operated at 420 nm illumination wavelength through the contrast analysis of PSMPs images. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  1. Time-resolved imaging refractometry of microbicidal films using quantitative phase microscopy

    PubMed Central

    Rinehart, Matthew T.; Drake, Tyler K.; Robles, Francisco E.; Rohan, Lisa C.; Katz, David; Wax, Adam

    2011-01-01

    Quantitative phase microscopy is applied to image temporal changes in the refractive index (RI) distributions of solutions created by microbicidal films undergoing hydration. We present a novel method of using an engineered polydimethylsiloxane structure as a static phase reference to facilitate calibration of the absolute RI across the entire field. We present a study of dynamic structural changes in microbicidal films during hydration and subsequent dissolution. With assumptions about the smoothness of the phase changes induced by these films, we calculate absolute changes in the percentage of film in regions across the field of view. PMID:22191912

  2. Orientational Order in Liquid Crystal Complexes Based on Lanthanides

    NASA Astrophysics Data System (ADS)

    Dobrun, L. A.; Kovshik, A. P.; Ryumtsev, E. I.; Kalinkin, A. A.

    2018-04-01

    In this study, we have for the first time determined the degree of an orientational order S for a series of liquid-crystal complexes based on lanthanides (Eu+3, Gd+3, Tb+3, Dy+3) with the same ligand composition in the temperature range of existence of the nematic phase by using experimental refractometry results. We have also found an even-odd alternative S as number of protons in the ions complexing agent has consecutively increased. The obtained values of S have been compared with the corresponding degrees of order of the calamite organic liquid crystals.

  3. Polysaccharide characterization by hollow-fiber flow field-flow fractionation with on-line multi-angle static light scattering and differential refractometry.

    PubMed

    Pitkänen, Leena; Striegel, André M

    2015-02-06

    Accurate characterization of the molar mass and size of polysaccharides is an ongoing challenge, oftentimes due to architectural diversity but also to the broad molar mass (M) range over which a single polysaccharide can exist and to the ultra-high M of many polysaccharides. Because of the latter, many of these biomacromolecules experience on-column, flow-induced degradation during analysis by size-exclusion and, even, hydrodynamic chromatography (SEC and HDC, respectively). The necessity for gentler fractionation methods has, to date, been addressed employing asymmetric flow field-flow fractionation (AF4). Here, we introduce the coupling of hollow-fiber flow field-flow fractionation (HF5) to multi-angle static light scattering (MALS) and differential refractometry (DRI) detection for the analysis of polysaccharides. In HF5, less stresses are placed on the macromolecules during separation than in SEC or HDC, and HF5 can offer a higher sensitivity, with less propensity for system overloading and analyte aggregation, than generally found in AF4. The coupling to MALS and DRI affords the determination of absolute, calibration-curve-independent molar mass averages and dispersities. Results from the present HF5/MALS/DRI experiments with dextrans, pullulans, and larch arabinogalactan were augmented with hydrodynamic radius (RH) measurements from off-line quasi-elastic light scattering (QELS) and by RH distribution calculations and fractogram simulations obtained via a finite element analysis implementation of field-flow fractionation theory by commercially available software. As part of this study, we have investigated analyte recovery in HF5 and also possible reasons for discrepancies between calculated and simulated results vis-à-vis experimentally determined data. Published by Elsevier B.V.

  4. Comparison of an infrared anaesthetic agent analyser (Datex-Ohmeda) with refractometry for measurement of isoflurane, sevoflurane and desflurane concentrations.

    PubMed

    Rudolff, Andrea S; Moens, Yves P S; Driessen, Bernd; Ambrisko, Tamas D

    2014-07-01

    To assess agreement between infrared (IR) analysers and a refractometer for measurements of isoflurane, sevoflurane and desflurane concentrations and to demonstrate the effect of customized calibration of IR analysers. In vitro experiment. Six IR anaesthetic monitors (Datex-Ohmeda) and a single portable refractometer (Riken). Both devices were calibrated following the manufacturer's recommendations. Gas samples were collected at common gas outlets of anaesthesia machines. A range of agent concentrations was produced by stepwise changes in dial settings: isoflurane (0-5% in 0.5% increments), sevoflurane (0-8% in 1% increments), or desflurane (0-18% in 2% increments). Oxygen flow was 2 L minute(-1) . The orders of testing IR analysers, agents and dial settings were randomized. Duplicate measurements were performed at each setting. The entire procedure was repeated 24 hours later. Bland-Altman analysis was performed. Measurements on day-1 were used to yield calibration equations (IR measurements as dependent and refractometry measurements as independent variables), which were used to modify the IR measurements on day-2. Bias ± limits of agreement for isoflurane, sevoflurane and desflurane were 0.2 ± 0.3, 0.1 ± 0.4 and 0.7 ± 0.9 volume%, respectively. There were significant linear relationships between differences and means for all agents. The IR analysers became less accurate at higher gas concentrations. After customized calibration, the bias became almost zero and the limits of agreement became narrower. If similar IR analysers are used in research studies, they need to be calibrated against a reference method using the agent in question at multiple calibration points overlapping the range of interest. © 2013 Association of Veterinary Anaesthetists and the American College of Veterinary Anesthesia and Analgesia.

  5. Simultaneous measurement of monocomponent droplet temperature/refractive index, size and evaporation rate with phase rainbow refractometry

    NASA Astrophysics Data System (ADS)

    Wu, Yingchun; Crua, Cyril; Li, Haipeng; Saengkaew, Sawitree; Mädler, Lutz; Wu, Xuecheng; Gréhan, Gérard

    2018-07-01

    The accurate measurements of droplet temperature, size and evaporation rate are of great importance to characterize the heat and mass transfer during evaporation/condensation processes. The nanoscale size change of a micron-sized droplet exactly describes its transient mass transfer, but is difficult to measure because it is smaller than the resolutions of current size measurement techniques. The Phase Rainbow Refractometry (PRR) technique is developed and applied to measure droplet temperature, size and transient size changes and thereafter evaporation rate simultaneously. The measurement principle of PRR is theoretically derived, and it reveals that the phase shift of the time-resolved ripple structures linearly depends on, and can directly yield, nano-scale size changes of droplets. The PRR technique is first verified through the simulation of rainbows of droplets with changing size, and results show that PRR can precisely measure droplet refractive index, absolute size, as well as size change with absolute and relative errors within several nanometers and 0.6%, respectively, and thus PRR permits accurate measurements of transient droplet evaporation rates. The evaporations of flowing single n-nonane droplet and mono-dispersed n-heptane droplet stream are investigated by two PRR systems with a high speed linear CCD and a low speed array CCD, respectively. Their transient evaporation rates are experimentally determined and quantitatively agree well with the theoretical values predicted by classical Maxwell and Stefan-Fuchs models. With the demonstration of evaporation rate measurement of monocomponent droplet in this work, PRR is an ideal tool for measurements of transient droplet evaporation/condensation processes, and can be extended to multicomponent droplets in a wide range of industrially-relevant applications.

  6. Polarimetry diagnostic on OMEGA EP using a 10-ps, 263-nm probe beam.

    PubMed

    Davies, A; Haberberger, D; Boni, R; Ivancic, S; Brown, R; Froula, D H

    2014-11-01

    A polarimetry diagnostic was built and characterized for magnetic-field measurements in laser-plasma experiments on the OMEGA EP laser. This diagnostic was built into the existing 4ω (263-nm) probe system that employs a 10-ps laser pulse collected with an f/4 imaging system. The diagnostic measures the rotation of the probe beam's polarization. The polarimeter uses a Wollaston prism to split the probe beam into orthogonal polarization components. Spatially localized intensity variations between images indicate polarization rotation. Magnetic fields can be calculated by combining the polarimetry data with the measured plasma density profile obtained from angular filter refractometry.

  7. Determination of the refractive index of glucose-ethanol-water mixtures using spectroscopic refractometry near the critical angle.

    PubMed

    Sobral, H; Peña-Gomar, M

    2015-10-01

    A spectroscopic refractometer was used to investigate the dispersion curves of ethanol and D-glucose solutions in water near the critical angle; here, the reflectivity was measured using a white source. Dispersion curves were obtained in the 320-1000 nm wavelength range with a resolution better than 10(-4) for the refractive index, n. The differential refractive index is measured as a function of wavelength, and a simple expression is proposed to obtain the refractive index of the glucose-ethanol-water ternary system. Using this expression, combined with the experimental differential refractive index values, the concentrations of individual components can be calculated.

  8. Phase rainbow refractometry for accurate droplet variation characterization.

    PubMed

    Wu, Yingchun; Promvongsa, Jantarat; Saengkaew, Sawitree; Wu, Xuecheng; Chen, Jia; Gréhan, Gérard

    2016-10-15

    We developed a one-dimensional phase rainbow refractometer for the accurate trans-dimensional measurements of droplet size on the micrometer scale as well as the tiny droplet diameter variations at the nanoscale. The dependence of the phase shift of the rainbow ripple structures on the droplet variations is revealed. The phase-shifting rainbow image is recorded by a telecentric one-dimensional rainbow imaging system. Experiments on the evaporating monodispersed droplet stream show that the phase rainbow refractometer can measure the tiny droplet diameter changes down to tens of nanometers. This one-dimensional phase rainbow refractometer is capable of measuring the droplet refractive index and diameter, as well as variations.

  9. Plasmon-enhanced refractometry using silver nanowire coatings on tilted fibre Bragg gratings.

    PubMed

    Bialiayeu, A; Bottomley, A; Prezgot, D; Ianoul, A; Albert, J

    2012-11-09

    A novel technique for increasing the sensitivity of tilted fibre Bragg grating (TFBG) based refractometers is presented. The TFBG sensor was coated with chemically synthesized silver nanowires ~100 nm in diameter and several micrometres in length. A 3.5-fold increase in sensor sensitivity was obtained relative to the uncoated TFBG sensor. This increase is associated with the excitation of surface plasmons by orthogonally polarized fibre cladding modes at wavelengths near 1.5 μm. Refractometric information is extracted from the sensor via the strong polarization dependence of the grating resonances using a Jones matrix analysis of the transmission spectrum of the fibre.

  10. Optical sensing: recognition elements and devices

    NASA Astrophysics Data System (ADS)

    Gauglitz, Guenter G.

    2012-09-01

    The requirements in chemical and biochemical sensing with respect to recognition elements, avoiding non-specific interactions, and high loading of the surface for detection of low concentrations as well as optimized detection systems are discussed. Among the many detection principles the optical techniques are classified. Methods using labeled compounds like Total Internal Reflection Fluorescence (TIRF) and direct optical methods like micro reflectometry or refractometry are discussed in comparison. Reflectometric Interference Spectroscopy (RIfS) is presented as a robust simple method for biosensing. As applications, trace analysis of endocrine disruptors in water, hormones in food, detection of viruses and bacteria in food and clinical diagnostics are discussed.

  11. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kulchin, Yurii N; Vitrik, O B; Gurbatov, S O

    The phase of light propagating through a bent optical fibre is shown to depend on the refractive index of the medium surrounding the fibre cladding when there is resonance coupling between the guided core mode and cladding modes. This shifts the spectral maxima in the bent fibre-optic Fabry - Perot interferometer. The highest phase and spectral sensitivities achieved with this interferometer configuration are 0.71 and 0.077, respectively, and enable changes in the refractive index of the ambient medium down to 5 Multiplication-Sign 10{sup -6} to be detected. This makes the proposed approach potentially attractive for producing highly stable, precision refractivemore » index sensors capable of solving a wide range of liquid refractometry problems.« less

  12. Spectro-refractometry of individual microscopic objects using swept-source quantitative phase imaging.

    PubMed

    Jung, Jae-Hwang; Jang, Jaeduck; Park, Yongkeun

    2013-11-05

    We present a novel spectroscopic quantitative phase imaging technique with a wavelength swept-source, referred to as swept-source diffraction phase microscopy (ssDPM), for quantifying the optical dispersion of microscopic individual samples. Employing the swept-source and the principle of common-path interferometry, ssDPM measures the multispectral full-field quantitative phase imaging and spectroscopic microrefractometry of transparent microscopic samples in the visible spectrum with a wavelength range of 450-750 nm and a spectral resolution of less than 8 nm. With unprecedented precision and sensitivity, we demonstrate the quantitative spectroscopic microrefractometry of individual polystyrene beads, 30% bovine serum albumin solution, and healthy human red blood cells.

  13. Use of refractometry as a new management tool in AI boar centers for quality assurance of extender preparations.

    PubMed

    Schulze, M; Rüdiger, K; Jung, M; Grossfeld, R

    2015-01-01

    A study was performed to see if refractometry can be used as a new quality control tool for boar semen extenders. For this the refractive index and osmolality of BTS extender concentrations (EC) were recorded in 10%-steps from 50% to 150% and 200% of the correct amount. Twelve boar ejaculates were evaluated for semen quality. The refractive index for the correctly prepared extender was 4.6±0.0°Bx, corresponded to 316±16mOsmkg(-1), and correlated highly with osmolality (r=0.99; P<0.001). Total sperm motility with 100% EC differed significantly from ≤70% EC (P<0.001) and 200% EC (P<0.001) on day 1 (d1) and d4, respectively. The percentage of motile spermatozoa in a thermoresistance test on d2 showed a significant drop using ≤70% EC (P=0.047) and ≥140% EC (P=0.004). Secondary apical ridge defects were significantly higher using 50% EC (P<0.001) and ≥150% EC (P=0.032) compared to 100% EC, respectively. An increased number of coiled tails were observed using ≤60% EC (P<0.001). Percentages of spermatozoa with intact membranes on d2 resulted in a significant decrease using 50% EC (P<0.001) and ≥150% EC (P=0.005), respectively. The mean percentage of PI negative spermatozoa with active mitochondria on d2 showed a significant difference using ≤60% EC (P=0.016) and ≥140% EC (P<0.001) compared to 100% EC, respectively. Boar sperm quality is affected by inexact extender preparation. The refractive-index is an indicator of osmolality and may be used to verify semen extender preparation. The sensitivity is sufficient to detect deviations from correct extender preparation before negative effects on sperm quality occur. Copyright © 2014 Elsevier B.V. All rights reserved.

  14. Immersion Refractometry of Isolated Bacterial Cell Walls

    PubMed Central

    Marquis, Robert E.

    1973-01-01

    Immersion-refractometric and light-scattering measurements were adapted to determinations of average refractive indices and physical compactness of isolated bacterial cell walls. The structures were immersed in solutions containing various concentrations of polymer molecules that cannot penetrate into wall pores, and then an estimate was made of the polymer concentration or the refractive index of the polymer solution in which light scattering was reduced to zero. Because each wall preparation was heterogeneous, the refractive index of the medium for zero light scattering had to be estimated by extrapolation. Refractive indices for walls suspended in bovine serum albumin solutions ranged from 1.348 for walls of the rod form of Arthrobacter crystallopoietes to 1.382 for walls of the teichoic acid deficient, 52A5 strain of Staphylococcus aureus. These indices were used to calculate approximate values for solids content per milliliter, and the calculated values agreed closely with those estimated from a knowledge of dextran-impermeable volumes per gram, dry weight, of the walls. When large molecules such as dextrans or serum albumin were used for immersion refractometry, the refractive indices obtained were for entire walls, including both wall polymers and wall water. When smaller molecules that can penetrate wall pores to various extents were used with Micrococcus lysodeikticus walls, the average, apparent refractive index of the structures increased as the molecular size of probing molecules was decreased. It was possible to obtain an estimate of 1.45 to 1.46 for the refractive index of wall polymers, predominantly peptidoglycans in this case, by extrapolating the curve for refractive index versus molecular radius to a value of 0.2 nm, the approximate radius of a water molecule. This relatively low value for polymer refractive index was interpreted as evidence in favor of the amorphous, elastic model of peptidoglycan structure and against the crystalline, rigid model. PMID:4201772

  15. Laser-hole boring into overdense plasmas measured with soft X-Ray laser probing

    PubMed

    Takahashi; Kodama; Tanaka; Hashimoto; Kato; Mima; Weber; Barbee; Da Silva LB

    2000-03-13

    A laser self-focused channel formation into overdense plasmas was observed using a soft x-ray laser probe system with a grid image refractometry (GIR) technique. 1.053 &mgr;m laser light with a 100 ps pulse duration was focused onto a preformed plasma at an intensity of 2x10(17) W/cm (2). Cross sections of the channel were obtained which show a 30 &mgr;m diameter in overdense plasmas. The channel width in the overdense region was kept narrow as a result of self-focusing. Conically diverging density ridges were also observed along the channel, indicating a Mach cone created by a shock wave due to the supersonic propagation of the channel front.

  16. Material limitations on the detection limit in refractometry.

    PubMed

    Skafte-Pedersen, Peder; Nunes, Pedro S; Xiao, Sanshui; Mortensen, Niels Asger

    2009-01-01

    We discuss the detection limit for refractometric sensors relying on high-Q optical cavities and show that the ultimate classical detection limit is given by min {Δn} ≳ η, with n + iη being the complex refractive index of the material under refractometric investigation. Taking finite Q factors and filling fractions into account, the detection limit declines. As an example we discuss the fundamental limits of silicon-based high-Q resonators, such as photonic crystal resonators, for sensing in a bio-liquid environment, such as a water buffer. In the transparency window (λ ≳ 1100 nm) of silicon the detection limit becomes almost independent on the filling fraction, while in the visible, the detection limit depends strongly on the filling fraction because the silicon absorbs strongly.

  17. Comparison of urine specific gravity values from total-solids refractometry and reagent strip method.

    PubMed

    Chatasingh, S; Tapaneya-Olarn, W

    1989-01-01

    The comparison of specific gravity values of 561 urine samples from TS meter and reagent strip was made. The data were divided into two groups: group 1-less than 2+ protein contained urine samples and group 2--equal or more than 2+ protein contained urine samples. The results revealed that the specific gravity values from both methods in both groups were statistically different (p less than 0.01) but they were correlated at r = 0.84 (p less than 0.001) and r = 0.73 (p less than 0.001) in group 1 and group 2, respectively. It was concluded that the reagent strip is suitable for use as a screening test but it should not be considered when precise measurement is necessary.

  18. Schlieren Cinematography of Current Driven Plasma Jet Dynamics

    NASA Astrophysics Data System (ADS)

    Loebner, Keith; Underwood, Thomas; Cappelli, Mark

    2016-10-01

    Schlieren cinematography of a pulsed plasma deflagration jet is presented and analyzed. An ultra-high frame rate CMOS camera coupled to a Z-type laser Schlieren apparatus is used to obtain flow-field refractometry data for the continuous flow Z-pinch formed within the plasma deflagration jet. The 10 MHz frame rate for 256 consecutive frames provides high temporal resolution, enabling turbulent fluctuations and plasma instabilities to be visualized over the course of a single pulse (20 μs). The Schlieren signal is radiometrically calibrated to obtain a two dimensional mapping of the refraction angle of the axisymmetric pinch plasma, and this mapping is then Abel inverted to derive the plasma density distribution as a function radius, axial coordinate, and time. Analyses of previously unknown discharge characteristics and comparisons with prior work are discussed.

  19. Absolute near-infrared refractometry with a calibrated tilted fiber Bragg grating.

    PubMed

    Zhou, Wenjun; Mandia, David J; Barry, Seán T; Albert, Jacques

    2015-04-15

    The absolute refractive indices (RIs) of water and other liquids are determined with an uncertainty of ±0.001 at near-infrared wavelengths by using the tilted fiber Bragg grating (TFBG) cladding mode resonances of a standard single-mode fiber to measure the critical angle for total internal reflection at the interface between the fiber and its surroundings. The necessary condition to obtain absolute RIs (instead of measuring RI changes) is a thorough characterization of the dispersion of the core mode effective index of the TFBG across the full range of its cladding mode resonance spectrum. This technique is shown to be competitive with the best available measurements of the RIs of water and NaCl solutions at wavelengths in the vicinity of 1550 nm.

  20. Evanescent field refractometry in planar optical fiber.

    PubMed

    Holmes, Christopher; Jantzen, Alexander; Gray, Alan C; Gow, Paul C; Carpenter, Lewis G; Bannerman, Rex H S; Gates, James C; Smith, Peter G R

    2018-02-15

    This Letter demonstrates a refractometer in integrated optical fiber, a new optical platform that planarizes fiber using flame hydrolysis deposition (FHD). The unique advantage of the technology is survivability in harsh environments. The platform is mechanically robust, and can survive elevated temperatures approaching 1000°C and exposure to common solvents, including acetone, gasoline, and methanol. For the demonstrated refractometer, fabrication was achieved through wet etching an SMF-28 fiber to a diameter of 8 μm before FHD planarization. An external refractive index was monitored using fiber Bragg gratings (FBGs), written into the core of the planarized fiber. A direct comparison to alternative FBG refractometers is made, for which the developed platform is shown to have comparable sensitivity, with the added advantage of survivability in harsh environments.

  1. Material Limitations on the Detection Limit in Refractometry

    PubMed Central

    Skafte-Pedersen, Peder; Nunes, Pedro S.; Xiao, Sanshui; Mortensen, Niels Asger

    2009-01-01

    We discuss the detection limit for refractometric sensors relying on high-Q optical cavities and show that the ultimate classical detection limit is given by min {Δn} ≳ η, with n + iη being the complex refractive index of the material under refractometric investigation. Taking finite Q factors and filling fractions into account, the detection limit declines. As an example we discuss the fundamental limits of silicon-based high-Q resonators, such as photonic crystal resonators, for sensing in a bio-liquid environment, such as a water buffer. In the transparency window (λ ≳ 1100 nm) of silicon the detection limit becomes almost independent on the filling fraction, while in the visible, the detection limit depends strongly on the filling fraction because the silicon absorbs strongly. PMID:22291513

  2. Quantification of Soluble Sugars and Sugar Alcohols by LC-MS/MS.

    PubMed

    Feil, Regina; Lunn, John Edward

    2018-01-01

    Sugars are simple carbohydrates composed primarily of carbon, hydrogen, and oxygen. They play a central role in metabolism as sources of energy and as building blocks for synthesis of structural and nonstructural polymers. Many different techniques have been used to measure sugars, including refractometry, colorimetric and enzymatic assays, gas chromatography, high-performance liquid chromatography, and nuclear magnetic resonance spectroscopy. In this chapter we describe a method that combines an initial separation of sugars by high-performance anion-exchange chromatography (HPAEC) with detection and quantification by tandem mass spectrometry (MS/MS). This combination of techniques provides exquisite specificity, allowing measurement of a diverse range of high- and low-abundance sugars in biological samples. This method can also be used for isotopomer analysis in stable-isotope labeling experiments to measure metabolic fluxes.

  3. Zero-order bows in radially inhomogeneous spheres: direct and inverse problems.

    PubMed

    Adam, John A

    2011-10-01

    Zero-order ray paths are examined in radially inhomogeneous spheres with differentiable refractive index profiles. It is demonstrated that zero-order and sometimes twin zero-order bows can exist when the gradient of refractive index is sufficiently negative. Abel inversion is used to "recover" the refractive index profiles; it is therefore possible in principle to specify the nature and type of bows and determine the refractive index profile that induces them. This may be of interest in the field of rainbow refractometry and optical fiber studies. This ray-theoretic analysis has direct similarities with the phenomenon of "orbiting" and other phenomena in scattering theory and also in seismological, surface gravity wave, and gravitational "lensing" studies. For completeness these topics are briefly discussed in the appendixes; they may also be of pedagogic interest.

  4. Diagnostic accuracy of refractometry for assessing bovine colostrum quality: A systematic review and meta-analysis.

    PubMed

    Buczinski, S; Vandeweerd, J M

    2016-09-01

    Provision of good quality colostrum [i.e., immunoglobulin G (IgG) concentration ≥50g/L] is the first step toward ensuring proper passive transfer of immunity for young calves. Precise quantification of colostrum IgG levels cannot be easily performed on the farm. Assessment of the refractive index using a Brix scale with a refractometer has been described as being highly correlated with IgG concentration in colostrum. The aim of this study was to perform a systematic review of the diagnostic accuracy of Brix refractometry to diagnose good quality colostrum. From 101 references initially obtain ed, 11 were included in the systematic review meta-analysis representing 4,251 colostrum samples. The prevalence of good colostrum samples with IgG ≥50g/L varied from 67.3 to 92.3% (median 77.9%). Specific estimates of accuracy [sensitivity (Se) and specificity (Sp)] were obtained for different reported cut-points using a hierarchical summary receiver operating characteristic curve model. For the cut-point of 22% (n=8 studies), Se=80.2% (95% CI: 71.1-87.0%) and Sp=82.6% (71.4-90.0%). Decreasing the cut-point to 18% increased Se [96.1% (91.8-98.2%)] and decreased Sp [54.5% (26.9-79.6%)]. Modeling the effect of these Brix accuracy estimates using a stochastic simulation and Bayes theorem showed that a positive result with the 22% Brix cut-point can be used to diagnose good quality colostrum (posttest probability of a good colostrum: 94.3% (90.7-96.9%). The posttest probability of good colostrum with a Brix value <18% was only 22.7% (12.3-39.2%). Based on this study, the 2 cut-points could be alternatively used to select good quality colostrum (sample with Brix ≥22%) or to discard poor quality colostrum (sample with Brix <18%). When sample results are between these 2 values, colostrum supplementation should be considered. Copyright © 2016 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  5. Live cell refractometry using Hilbert phase microscopy and confocal reflectance microscopy.

    PubMed

    Lue, Niyom; Choi, Wonshik; Popescu, Gabriel; Yaqoob, Zahid; Badizadegan, Kamran; Dasari, Ramachandra R; Feld, Michael S

    2009-11-26

    Quantitative chemical analysis has served as a useful tool for understanding cellular metabolisms in biology. Among many physical properties used in chemical analysis, refractive index in particular has provided molecular concentration that is an important indicator for biological activities. In this report, we present a method of extracting full-field refractive index maps of live cells in their native states. We first record full-field optical thickness maps of living cells by Hilbert phase microscopy and then acquire physical thickness maps of the same cells using a custom-built confocal reflectance microscope. Full-field and axially averaged refractive index maps are acquired from the ratio of optical thickness to physical thickness. The accuracy of the axially averaged index measurement is 0.002. This approach can provide novel biological assays of label-free living cells in situ.

  6. Live Cell Refractometry Using Hilbert Phase Microscopy and Confocal Reflectance Microscopy†

    PubMed Central

    Lue, Niyom; Choi, Wonshik; Popescu, Gabriel; Yaqoob, Zahid; Badizadegan, Kamran; Dasari, Ramachandra R.; Feld, Michael S.

    2010-01-01

    Quantitative chemical analysis has served as a useful tool for understanding cellular metabolisms in biology. Among many physical properties used in chemical analysis, refractive index in particular has provided molecular concentration that is an important indicator for biological activities. In this report, we present a method of extracting full-field refractive index maps of live cells in their native states. We first record full-field optical thickness maps of living cells by Hilbert phase microscopy and then acquire physical thickness maps of the same cells using a custom-built confocal reflectance microscope. Full-field and axially averaged refractive index maps are acquired from the ratio of optical thickness to physical thickness. The accuracy of the axially averaged index measurement is 0.002. This approach can provide novel biological assays of label-free living cells in situ. PMID:19803506

  7. Tissue refractometry using Hilbert phase microscopy.

    PubMed

    Lue, Niyom; Bewersdorf, Joerg; Lessard, Mark D; Badizadegan, Kamran; Dasari, Ramachandra R; Feld, Michael S; Popescu, Gabriel

    2007-12-15

    We present, for the first time to our knowledge, quantitative phase images associated with unstained 5 mum thick tissue slices of mouse brain, spleen, and liver. The refractive properties of the tissue are retrieved in terms of the average refractive index and its spatial variation. We find that the average refractive index varies significantly with tissue type, such that the brain is characterized by the lowest value and the liver by the highest. The spatial power spectra of the phase images reveal power law behavior with different exponents for each tissue type. This approach opens a new possibility for stain-free characterization of tissues, where the diagnostic power is provided by the intrinsic refractive properties of the biological structure. We present results obtained for liver tissue affected by a lysosomal storage disease and show that our technique can quantify structural changes during this disease development.

  8. A novel method of measuring the concentration of anaesthetic vapours using a dew-point hygrometer.

    PubMed

    Wilkes, A R; Mapleson, W W; Mecklenburgh, J S

    1994-02-01

    The Antoine equation relates the saturated vapour pressure of a volatile substance, such as an anaesthetic agent, to the temperature. The measurement of the 'dew-point' of a dry gas mixture containing a volatile anaesthetic agent by a dew-point hygrometer permits the determination of the partial pressure of the anaesthetic agent. The accuracy of this technique is limited only by the accuracy of the Antoine coefficients and of the temperature measurement. Comparing measurements by the dew-point method with measurements by refractometry showed systematic discrepancies up to 0.2% and random discrepancies with SDS up to 0.07% concentration in the 1% to 5% range for three volatile anaesthetics. The systematic discrepancies may be due to errors in available data for the vapour pressures and/or the refractive indices of the anaesthetics.

  9. Influence of eye micromotions on spatially resolved refractometry

    NASA Astrophysics Data System (ADS)

    Chyzh, Igor H.; Sokurenko, Vyacheslav M.; Osipova, Irina Y.

    2001-01-01

    The influence eye micromotions on the accuracy of estimation of Zernike coefficients form eye transverse aberration measurements was investigated. By computer modeling, the following found eye aberrations have been examined: defocusing, primary astigmatism, spherical aberration of the 3rd and the 5th orders, as well as their combinations. It was determined that the standard deviation of estimated Zernike coefficients is proportional to the standard deviation of angular eye movements. Eye micromotions cause the estimation errors of Zernike coefficients of present aberrations and produce the appearance of Zernike coefficients of aberrations, absent in the eye. When solely defocusing is present, the biggest errors, cased by eye micromotions, are obtained for aberrations like coma and astigmatism. In comparison with other aberrations, spherical aberration of the 3rd and the 5th orders evokes the greatest increase of the standard deviation of other Zernike coefficients.

  10. LLE Review, Volume 57. Quarterly report, October--December 1993

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Simon, A.

    During this quarter, the visible fruits of long design labors on the OMEGA Upgrade began to appear. The target mirror structure was put in place, along with the target chamber itself. The laser bay structures were also installed, and the bay is now being prepared to receive optomechanical, control, and laser assemblies. Further details are in the OMEGA Upgrade Status Report in this issue. Theory and analysis of previous experiments continued during this reporting period. Articles contained herein describe an improved theory of the ablative Rayleigh-Taylor instability; a novel proposal for characterizing plasma-density profiles by using grid image refractometry; amore » much-improved treatment of the damping of ion sound waves in a mixture of light and heavy ions; and, finally, a new interpretation of measurements of 3/2-harmonic radiation emitted from the long-scale-length plasmas created in earlier OMEGA experiments.« less

  11. Determination of molecular weight of membrane proteins by the use of low-angle laser light scattering combined with high-performance gel chromatography in the presence of a non-ionic surfactant.

    PubMed

    Maezawa, S; Hayashi, Y; Nakae, T; Ishii, J; Kameyama, K; Takagi, T

    1983-09-28

    An assessment study was carried out to evaluate the performance of the low-angle laser light scattering technique combined with high-performance gel chromatography in the presence of a nonionic surfactant, octaethyleneglycol n-dodecyl ether, precision differential refractometry and ultraviolet photometry. It was found that the combined technique is highly promising as a method for the determination of the molecular weight of a membrane protein solubilized by the surfactant. For trial, molecular weights of the following membrane proteins of Escherichia coli, both solubilized in oligomeric forms, were measured; porin that forms the transmembrane diffusion pore in the outer membrane, and lambda-receptor protein that facilitates the diffusion of maltose-maltodextrins across the outer membrane. The result obtained indicates that both porin and lambda-receptor protein exist as trimers in the surfactant solution.

  12. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Froula, D. H.; Boni, R.; Bedzyk, M.

    A 10-ps, 263-nm (4{omega}) laser is being built to probe plasmas produced on the OMEGA EP [J. H. Kelly, L. J. Waxer, V. Bagnoud, I. A. Begishev, J. Bromage, B. E. Kruschwitz, T. E. Kessler, S. J. Loucks, D. N. Maywar, R. L. McCrory et al., J. Phys. IV France 133, 75-80 (2006)]. A suite of optical diagnostics (schlieren, interferometry, and grid image refractometry) has been designed to diagnose and characterize a wide variety of plasmas. Light scattered by the probe beam is collected by an f/4 catadioptric telescope and a transport system is designed to image with a near-diffraction-limitedmore » resolution ({approx}1 -{mu}m full width at half maximum) over a 5-mm field of view to a diagnostic table. The transport system provides a contrast greater than 1 : 10{sup 4} with respect to all wavelengths outside of the 263 {+-} 2 nm measurement range.« less

  13. Single-molecule spectromicroscopy: a route towards sub-wavelength refractometry.

    PubMed

    Anikushina, T A; Gladush, M G; Gorshelev, A A; Naumov, A V

    2015-01-01

    We suggest a novel approach for spatially resolved probing of local fluctuations of the refractive index n in solids by means of single-molecule (SM) spectroscopy. It is based on the dependence T1(n) of the effective radiative lifetime T1 of dye centres in solids on n due to the local-field effects. Detection of SM zero-phonon lines at low temperatures gives the values of the SM natural spectral linewidth (which is inversely proportional to T1) and makes it possible to reveal the distribution of the local n values in solids. Here we demonstrate this possibility on the example of amorphous polyethylene and polycrystalline naphthalene doped with terrylene. In particular, we show that the obtained distributions of lifetime limited spectral linewidths of terrylene molecules embedded into these matrices are due to the spatial fluctuations of the refractive index local values.

  14. Tissue refractometry using Hilbert phase microscopy

    PubMed Central

    Lue, Niyom; Bewersdorf, Joerg; Lessard, Mark D.; Badizadegan, Kamran; Dasari, Ramachandra R.; Feld, Michael S.; Popescu, Gabriel

    2009-01-01

    We present, for the first time to our knowledge, quantitative phase images associated with unstained 5 μm thick tissue slices of mouse brain, spleen, and liver. The refractive properties of the tissue are retrieved in terms of the average refractive index and its spatial variation. We find that the average refractive index varies significantly with tissue type, such that the brain is characterized by the lowest value and the liver by the highest. The spatial power spectra of the phase images reveal power law behavior with different exponents for each tissue type. This approach opens a new possibility for stain-free characterization of tissues, where the diagnostic power is provided by the intrinsic refractive properties of the biological structure. We present results obtained for liver tissue affected by a lysosomal storage disease and show that our technique can quantify structural changes during this disease development. PMID:18087529

  15. Measurements of laser-hole boring into overdense plasmas using x-ray laser refractometry (invited)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kodama, R.; Takahashi, K.; Tanaka, K.A.

    We developed a 19.6 nm laser x-ray laser grid-image refractometer (XRL-GIR) to diagnose laser-hole boring into overdense plasmas. The XRL-GIR was optimized to measure two-dimensional electron density perturbation on a scale of a few tens of {mu}m in underdense plasmas. Electron density profiles of laser-produced plasmas were obtained for 10{sup 20}{endash}10{sup 22}thinspcm{sup {minus}3} with the XRL-GIR and for 10{sup 19}{endash}10{sup 20}thinspcm{sup {minus}3} from an ultraviolet interferometer, the profiles of which were compared with those from hydrodynamic simulation. By using this XRL-GIR, we directly observed laser channeling into overdense plasmas accompanied by a bow shock wave showing a Mach cone ascribedmore » to supersonic propagation of the channel front. {copyright} {ital 1999 American Institute of Physics.}« less

  16. Solution and electron microscopy characterization of lactococcal phage baseplates expressed in Escherichia coli.

    PubMed

    Campanacci, Valérie; Veesler, David; Lichière, Julie; Blangy, Stéphanie; Sciara, Giuliano; Moineau, Sylvain; van Sinderen, Douwe; Bron, Patrick; Cambillau, Christian

    2010-10-01

    We report here the characterization of several large structural protein complexes forming the baseplates (or part of them) of Siphoviridae phages infecting Lactococcus lactis: TP901-1, Tuc2009 and p2. We revisited a "block cloning" expression strategy and extended this approach to genomic fragments encoding proteins whose interacting partners have not yet been clearly identified. Biophysical characterization of some of these complexes using circular dichroism and size exclusion chromatography, coupled with on-line light scattering and refractometry, demonstrated that the over-produced recombinant proteins interact with each other to form large (up to 1.9MDa) and stable baseplate assemblies. Some of these complexes were characterized by electron microscopy confirming their structural homogeneity as well as providing a picture of their overall molecular shapes and symmetry. Finally, using these results, we were able to highlight similarities and differences with the well characterized much larger baseplate of the myophage T4.

  17. Research at ITER towards DEMO: Specific reactor diagnostic studies to be carried out on ITER

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Krasilnikov, A. V.; Kaschuck, Y. A.; Vershkov, V. A.

    2014-08-21

    In ITER diagnostics will operate in the very hard radiation environment of fusion reactor. Extensive technology studies are carried out during development of the ITER diagnostics and procedures of their calibration and remote handling. Results of these studies and practical application of the developed diagnostics on ITER will provide the direct input to DEMO diagnostic development. The list of DEMO measurement requirements and diagnostics will be determined during ITER experiments on the bases of ITER plasma physics results and success of particular diagnostic application in reactor-like ITER plasma. Majority of ITER diagnostic already passed the conceptual design phase and representmore » the state of the art in fusion plasma diagnostic development. The number of related to DEMO results of ITER diagnostic studies such as design and prototype manufacture of: neutron and γ–ray diagnostics, neutral particle analyzers, optical spectroscopy including first mirror protection and cleaning technics, reflectometry, refractometry, tritium retention measurements etc. are discussed.« less

  18. Research at ITER towards DEMO: Specific reactor diagnostic studies to be carried out on ITER

    NASA Astrophysics Data System (ADS)

    Krasilnikov, A. V.; Kaschuck, Y. A.; Vershkov, V. A.; Petrov, A. A.; Petrov, V. G.; Tugarinov, S. N.

    2014-08-01

    In ITER diagnostics will operate in the very hard radiation environment of fusion reactor. Extensive technology studies are carried out during development of the ITER diagnostics and procedures of their calibration and remote handling. Results of these studies and practical application of the developed diagnostics on ITER will provide the direct input to DEMO diagnostic development. The list of DEMO measurement requirements and diagnostics will be determined during ITER experiments on the bases of ITER plasma physics results and success of particular diagnostic application in reactor-like ITER plasma. Majority of ITER diagnostic already passed the conceptual design phase and represent the state of the art in fusion plasma diagnostic development. The number of related to DEMO results of ITER diagnostic studies such as design and prototype manufacture of: neutron and γ-ray diagnostics, neutral particle analyzers, optical spectroscopy including first mirror protection and cleaning technics, reflectometry, refractometry, tritium retention measurements etc. are discussed.

  19. Station report on the Goddard Space Flight Center (GSFC) 1.2 meter telescope facility

    NASA Technical Reports Server (NTRS)

    Mcgarry, Jan F.; Zagwodzki, Thomas W.; Abbott, Arnold; Degnan, John J.; Cheek, Jack W.; Chabot, Richard S.; Grolemund, David A.; Fitzgerald, Jim D.

    1993-01-01

    The 1.2 meter telescope system was built for the Goddard Space Flight Center (GSFC) in 1973-74 by the Kollmorgen Corporation as a highly accurate tracking telescope. The telescope is an azimuth-elevation mounted six mirror Coude system. The facility has been used for a wide range of experimentation including helioseismology, two color refractometry, lunar laser ranging, satellite laser ranging, visual tracking of rocket launches, and most recently satellite and aircraft streak camera work. The telescope is a multi-user facility housed in a two story dome with the telescope located on the second floor above the experimenter's area. Up to six experiments can be accommodated at a given time, with actual use of the telescope being determined by the location of the final Coude mirror. The telescope facility is currently one of the primary test sites for the Crustal Dynamics Network's new UNIX based telescope controller software, and is also the site of the joint Crustal Dynamics Project / Photonics Branch two color research into atmospheric refraction.

  20. Refractometry of melanocyte cell nuclei using optical scatter images recorded by digital Fourier microscopy.

    PubMed

    Seet, Katrina Y T; Nieminen, Timo A; Zvyagin, Andrei V

    2009-01-01

    The cell nucleus is the dominant optical scatterer in the cell. Neoplastic cells are characterized by cell nucleus polymorphism and polychromism-i.e., the nuclei exhibits an increase in the distribution of both size and refractive index. The relative size parameter, and its distribution, is proportional to the product of the nucleus size and its relative refractive index and is a useful discriminant between normal and abnormal (cancerous) cells. We demonstrate a recently introduced holographic technique, digital Fourier microscopy (DFM), to provide a sensitive measure of this relative size parameter. Fourier holograms were recorded and optical scatter of individual scatterers were extracted and modeled with Mie theory to determine the relative size parameter. The relative size parameter of individual melanocyte cell nuclei were found to be 16.5+/-0.2, which gives a cell nucleus refractive index of 1.38+/-0.01 and is in good agreement with previously reported data. The relative size parameters of individual malignant melanocyte cell nuclei are expected to be greater than 16.5.

  1. Temperature influence on the cladding mode distribution in highly localized point-by-point fibre Bragg gratings

    NASA Astrophysics Data System (ADS)

    Caucheteur, C.; Gonzalez-Vila, A.; Chikh-Bled, H.; Lasri, B.; Kinet, D.; Chah, K.

    2016-05-01

    An infrared femtosecond pulses laser is used to manufacture point-by-point gratings in telecommunication-grade optical fibres. The refractive index modulations are localized close to the core-cladding interface, yielding a strong coupling to cladding mode resonances together with an important photo-induced birefringence. Such gratings have been recently used for refractrometric measurements. In this work, their transmitted amplitude spectrum is measured with polarized light while they are exposed to temperature changes up to 900 °C. Despite an overall good thermal stability of the gratings that confirms their robustness for high-temperature refractometry, we report an interesting polarization effect depending on both the cladding mode resonance family (radially- and azimuthally-polarized modes) and mode order. While the birefringence of the core mode resonance decreases with the temperature, certain cladding mode resonances show an increase of the wavelength splitting between their orthogonally-polarized components. This differential behaviour can be of high interest to develop high-resolution multiparametric sensing platforms.

  2. Surface Behavior of BSA/Water/Carbohydrate Systems from Molecular Polarizability Measurements.

    PubMed

    Alvarado, Ysaías J; Ferrebuz, Atilio; Paz, Jose Luis; Rodríguez-Lugo, Patricia; Restrepo, Jelem; Romero, Freddy; Fernández-Acuña, Jaqueline; Williams, Yhan O'Neil; Toro-Mendoza, Jhoan

    2018-04-19

    The effect of the presence of glucose and sucrose on the nonintrinsic contribution to partial molar volume ⟨Θ⟩ ni of bovine serum albumin (BSA) is determined by means of static and dynamic electronic polarizability measurements. For that aim, a combined strategy based on high-resolution refractometry, high exactitude densitometry, and synchronous fluorescence spectroscopy is applied. Both static and dynamic mean electronic molecular polarizability values are found to be sensitive to the presence of glucose. In the case of sucrose, the polarizability of BSA is not appreciably affected. In fact, our results revealed that the electronic changes observed occurred without a modification of the native conformation of BSA. On the contrary, a nonmonotonous behavior with the concentration is observed in presence of glucose. These results advocate the influence of the electronic polarization on the repulsive and attractive protein-carbohydrate interactions. An analysis using the scaled particle theory indicates that the accumulation of glucose on the protein surface promotes dehydration. Inversely, hydration and preferential exclusion occur in the vicinity of the protein surface for sucrose-enriched systems.

  3. Near-Membrane Refractometry Using Supercritical Angle Fluorescence.

    PubMed

    Brunstein, Maia; Roy, Lopamudra; Oheim, Martin

    2017-05-09

    Total internal reflection fluorescence (TIRF) microscopy and its variants are key technologies for visualizing the dynamics of single molecules or organelles in live cells. Yet truly quantitative TIRF remains problematic. One unknown hampering the interpretation of evanescent-wave excited fluorescence intensities is the undetermined cell refractive index (RI). Here, we use a combination of TIRF excitation and supercritical angle fluorescence emission detection to directly measure the average RI in the "footprint" region of the cell during image acquisition. Our RI measurement is based on the determination on a back-focal plane image of the critical angle separating evanescent and far-field fluorescence emission components. We validate our method by imaging mouse embryonic fibroblasts and BON cells. By targeting various dyes and fluorescent-protein chimeras to vesicles, the plasma membrane, as well as mitochondria and the endoplasmic reticulum, we demonstrate local RI measurements with subcellular resolution on a standard TIRF microscope, with a removable Bertrand lens as the only modification. Our technique has important applications for imaging axial vesicle dynamics and the mitochondrial energy state or detecting metabolically more active cancer cells. Copyright © 2017. Published by Elsevier Inc.

  4. Refractometric total protein concentrations in icteric serum from dogs.

    PubMed

    Gupta, Aradhana; Stockham, Steven L

    2014-01-01

    To determine whether high serum bilirubin concentrations interfere with the measurement of serum total protein concentration by refractometry and to assess potential biases among refractometer measurements. Evaluation study. Sera from 2 healthy Greyhounds. Bilirubin was dissolved in 0.1M NaOH, and the resulting solution was mixed with sera from 2 dogs from which food had been withheld to achieve various bilirubin concentrations up to 40 mg/dL. Refractometric total protein concentrations were estimated with 3 clinical refractometers. A biochemical analyzer was used to measure biuret assay-based total protein and bilirubin concentrations with spectrophotometric assays. No interference with refractometric measurement of total protein concentrations was detected with bilirubin concentrations up to 41.5 mg/dL. Biases in refractometric total protein concentrations were detected and were related to the conversion of refractive index values to total protein concentrations. Hyperbilirubinemia did not interfere with the refractometric estimation of serum total protein concentration. The agreement among total protein concentrations estimated by 3 refractometers was dependent on the method of conversion of refractive index to total protein concentration and was independent of hyperbilirubinemia.

  5. Structure of the nucleoid in cells of Streptococcus faecalis.

    PubMed Central

    Daneo-Moore, L; Dicker, D; Higgins, M L

    1980-01-01

    The structure of the nucleoid of Streptococcus faecalis (ATCC 9790) was examined and compared in the unfixed and fixed states by immersive refractometry and electron microscopy. It appears from these studies that the nucleoid structure is much more centralized in unfixed chloramphenicol-treated (stationary-phase) cells than it is in cells in the exponential phase of growth. The more dispersed configuration of the exponential-phase nucleoid could be preserved by fixation in glutaraldehyde, but not in Formalin or in osmium tetroxide. One important factor in explaining these differences in preservation is that glutaraldehyde (but not Formalin or osmium tetroxide) can rapidly cross-link the amino groups of macromolecules in cells. It was also observed that osmium tetroxide resulted in a preferential breakdown of nascent ribonucleic acid. These results are interpreted as indicating that glutaraldehyde is able to stabilize the exponential-phase nucleoid before it assumes the more central appearance seen in osmium tetroxide- and Formalin-fixed cells. These results are discussed in terms of the proposed organization of the exponential-phase nucleoid in unfixed cells. Images PMID:6767695

  6. Influence of spatial curvature of a liquid jet on the rainbow positions: Ray tracing and experimental study

    NASA Astrophysics Data System (ADS)

    Duan, Qingwei; Zhong, Ruliang; Han, Xiang'e.; Ren, Kuan Fang

    2017-07-01

    Rainbow refractometry is largely used in optical metrology of particles thanks to its advantages of being non-intrusive, precise and fast. Many authors have contributed to its development and the application in the characterization of liquid jets/droplets. The researches reported in the literature are mainly for the spherical droplets or the liquid jets which can be considered as a cylinder of constant section. However, the section of a real liquid jet, even in the simplest configuration, varies with distance from the exit. The influence of the spatial curvature of the jets must, therefore, be taken into account. In this paper, we report experimental measurements of the shifts of the rainbow positions in the horizontal and vertical directions of a liquid jet and the theoretical investigation with the vectorial complex ray model. It is shown that the shifts of rainbow positions are very sensitive to the spatial curvature of the jets. This work is hoped to provide a new approach to characterizing the structure and the instability of liquid jets.

  7. Colostrum immunoglobulin G concentration of multiparous Jersey cows at first and second milking is associated with parity, colostrum yield, and time of first milking, and can be estimated with Brix refractometry.

    PubMed

    Silva-Del-Río, N; Rolle, D; García-Muñoz, A; Rodríguez-Jiménez, S; Valldecabres, A; Lago, A; Pandey, P

    2017-07-01

    The objective of this study was to evaluate colostrum IgG concentration harvested at first and second milking from multiparous Jersey cows, the dam's lactation number, colostrum yield, and time of first milking. In addition, we validated the use of a Brix refractometer to estimate IgG concentration in colostrum from multiparous Jersey cows using radial immunodiffusion as the reference method. Colostrum samples and total weight of colostrum harvested at first (n = 134) and second (n = 68) milking were collected from 134 multiparous Jersey cows housed in a California herd. Fresh colostrum samples were analyzed for IgG concentration with Brix refractometry and frozen samples by radial immunodiffusion. A total of 90.4 and 42.7% of the samples from first and second milking met industry standards of quality for IgG concentration (>50 g/L). Second and third lactation cows had similar colostrum IgG concentration but lower than cows on their fourth and greater lactation. At second milking, 56.4% of cows on their fourth or greater lactation had colostrum IgG concentrations >50 g/L. When colostrum yield increased from low (<3 kg), medium (3 to 6 kg), to high (>6 kg), IgG concentration decreased. Higher IgG concentration was observed on colostrum harvested at <6 h (short) versus 6 to 11 h (medium) after calving. However, IgG concentration in colostrum harvested after 11 h (long) was similar to that harvested at short and medium time. Readings of %Brix were highly correlated with IgG at first (r = 0.81) and second (r = 0.77) milking. The best Brix threshold to identify colostrum from first milking with >50 IgG g/L was 20.9% based on logit equations with Youden's index criterion and 18.0% based on accuracy criterion. For colostrum harvested at second milking, similar Brix thresholds were obtained, 19.2 and 19.0%, regardless of whether Youden's index or accuracy was used as the selection criterion. Our results indicate that the dam's lactation number, colostrum yield, and time of first milking relative to calving are associated with IgG concentration in colostrum from multiparous Jersey cows. Second milking colostrum from mature Jersey cows should be evaluated to extend colostrum supply on dairies especially during times of shortage. Readings of %Brix can be used to rapidly estimate IgG concentration in Jersey colostrum harvested at first and second milking. Copyright © 2017 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  8. Vitrified chiral-nematic liquid crystalline films for selective reflection and circular polarization

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Katsis, D.; Chen, P.H.M.; Mastrangelo, J.C.

    Nematic and left-handed chiral-nematic liquid crystals comprising methoxybiphenylbenzoate and (S)-(-)-1-phenylethylamine pendants to a cyclohexane core were synthesized and characterized. Although pristine samples were found to be polycrystalline, thermal quenching following heating to and annealing at elevated temperatures permitted the molecular orders characteristic of liquid crystalline mesomorphism to be frozen in the glassy state. Left at room temperature for 6 months, the vitrified liquid crystalline films showed no evidence of recrystallization. An orientational order parameter of 0.65 was determined with linear dichroism of a vitrified nematic film doped with Exalite 428 at a mole fraction of 0.0025. Birefringence dispersion of amore » blank vitrified nematic film was determined using a phase-difference method complemented by Abbe refractometry. A series of vitrified chiral-nematic films were prepared to demonstrate selective reflection and circular polarization with a spectral region tunable from blue to the infrared region by varying the chemical composition. The experimentally measured circular polarization spectra were found to agree with the Good-Karali theory in which all four system parameters were determined a priori: optical birefringence, average refractive index, selective reflection wavelength, and film thickness.« less

  9. Counter-propagating optical trapping system for size and refractive index measurement of microparticles.

    PubMed

    Flynn, Richard A; Shao, Bing; Chachisvilis, Mirianas; Ozkan, Mihrimah; Esener, Sadik C

    2006-01-15

    We propose and demonstrate a novel approach to measure the size and refractive index of microparticles based on two beam optical trapping, where forward scattered light is detected to give information about the particle. The counter-propagating optical trap measurement (COTM) system exploits the capability of optical traps to measure pico-Newton forces for microparticles' refractive index and size characterization. Different from the current best technique for microparticles' refractive index measurement, refractometry, a bulk technique requiring changing the fluid composition of the sample, our optical trap technique works with any transparent fluid and enables single particle analysis without the use of biological markers. A ray-optics model is used to explore the physical operation of the COTM system, predict system performance and aid system design. Experiments demonstrate the accuracy of refractive index measurement of Deltan=0.013 and size measurement of 3% of diameter with 2% standard deviation. Present performance is instrumentation limited, and a potential improvement by more than two orders of magnitude can be expected in the future. With further development in parallelism and miniaturization, the system offers advantages for cell manipulation and bioanalysis compatible with lab-on-a-chip systems.

  10. Development of a digital video-microscopy technique to study lactose crystallisation kinetics in situ.

    PubMed

    Arellano, María Paz; Aguilera, José Miguel; Bouchon, Pedro

    2004-11-15

    Polarised light microscopy was employed non-invasively to monitor lactose crystallisation from non-seeded supersaturated solutions in real time. Images were continuously recorded, processed and characterised by image analysis, and the results were compared with those obtained by refractometry. Three crystallisation temperatures (10, 20 and 30 degrees C) and three different levels of initial relative supersaturation (C/C(s)=1.95; 2.34; 3.15) were investigated. Induction times using the imaging technique proved to be substantially lower than those determined using refractive index. Lactose crystals were isolated digitally to determine geometrical parameters of interest, such as perimeter, diameter, area, roundness and Feret mean, and to derive crystal growth rates. Mean growth rates obtained for single crystals were fitted to a combined mass transfer model (R(2)=0.9766). The model allowed the effects of temperature and supersaturation on crystallisation rate to be clearly identified. It also suggested that, in this set of experiments, surface integration seemed to be the rate controlling step. It is believed that a similar experimental set-up could be implemented in a real food system to characterise a particular process where crystallisation control is of interest and where traditional techniques are difficult to implement.

  11. Sandwiched gold/PNIPAm/gold microstructures for smart plasmonics application: towards the high detection limit and Raman quantitative measurements.

    PubMed

    Elashnikov, R; Mares, D; Podzimek, T; Švorčík, V; Lyutakov, O

    2017-08-07

    A smart plasmonic sensor, comprising a layer of a stimuli-responsive polymer sandwiched between two gold layers, is reported. As a stimuli-responsive material, a monolayer of poly(N-isopropylacrylamide) (PNIPAm) crosslinked globules is used. A quasi-periodic structure of the top gold layer facilitates efficient excitation and serves as a support for plasmon excitation and propagation. The intermediate layer of PNIPAm efficiently entraps targeted molecules from solutions. The sensor structure was optimized for efficient light focusing in the "active" PNIPAm layer. The optimization was based on the time-resolved finite-element simulations, which take into account the thickness of gold layers, size of PNIPAm globules and Raman excitation wavelength (780 nm). The prepared structures were characterized using SEM, AFM, UV-Vis refractometry and goniometry. Additional AFM scans were performed in water at two temperatures corresponding to the collapsed and swollen PNIPAm states. The Raman measurements demonstrate a high detection limit and perfect reproducibility of the Raman scattering signal for the prepared sensor. In addition, the use of created SERS structures for the detection of relevant molecules in the medical, biological and safety fields was demonstrated.

  12. Application of refractometry to quality assurance monitoring of parenteral nutrition solutions.

    PubMed

    Chang, Wei-Kuo; Chao, You-Chen; Yeh, Ming-Kung

    2008-01-01

    Parenteral nutrition (PN) solution contains various concentrations of dextrose, amino acids, lipids, vitamins, electrolytes, and trace elements. Incorrect preparation of PN solution could lead to patient death. In this study we used the refractive index as a quality assurance tool to monitor the preparation of PN solution. Refractive indices of single nutrient components and PN solutions consisting of various concentrations of dextrose, amino acids, electrolytes, and lipids were measured. A mathematical equation and its linear plot were generated then used to predict the refractive index of the PN solution. The best-fit refractive index for PN solution (i.e., the predicted refractive index)=0.9798x(% dextrose)+1.2889x(% amino acids)+1.1017x(% lipids)+0.9440x(% sum of the electrolytes)+0.5367 (r2=0.99). This equation was validated by comparing the measured refractive indices of 500 clinical PN solutions to their predicted refractive indices. We found that 2 of the 500 prepared samples (0.4%) had less than the predicted refractive index (<95%). Refractive index can be used as a reliable quality assurance tool for monitoring PN preparation. Such information can be obtained at the bedside and used to confirm the accuracy of the PN solution composition.

  13. Molecular imprinted polymer-coated optical fiber sensor for the identification of low molecular weight molecules.

    PubMed

    Lépinay, Sandrine; Ianoul, Anatoli; Albert, Jacques

    2014-10-01

    A biomimetic optical probe for detecting low molecular weight molecules (maltol, 3-hydroxy-2-methyl-4H-pyran-4-one, molecular weight of 126.11 g/mol), was designed, fabricated, and characterized. The sensor couples a molecular imprinted polymer (MIP) and the Bragg grating refractometry technology into an optical fiber. The probe is fabricated first by inscribing tilted grating planes in the core of the fiber, and then by photopolymerization to immobilize a maltol imprinted MIP on the fiber cladding surface over the Bragg grating. The sensor response to the presence of maltol in different media is obtained by spectral interrogation of the fiber transmission signal. The results showed that the limit of detection of the sensor reached 1 ng/mL in pure water with a sensitivity of 6.3 × 10(8)pm/M. The selectivity of the sensor against other compounds and its reusability were also studied experimentally. Finally, the unambiguous detection of concentrations as little as 10nM of maltol in complex media (real food samples) by the MIP-coated tilted fiber Bragg grating sensor was demonstrated. Copyright © 2014 Elsevier B.V. All rights reserved.

  14. High precision refractometry based on Fresnel diffraction from phase plates.

    PubMed

    Tavassoly, M Taghi; Naraghi, Roxana Rezvani; Nahal, Arashmid; Hassani, Khosrow

    2012-05-01

    When a transparent plane-parallel plate is illuminated at a boundary region by a monochromatic parallel beam of light, Fresnel diffraction occurs because of the abrupt change in phase imposed by the finite change in refractive index at the plate boundary. The visibility of the diffraction fringes varies periodically with changes in incident angle. The visibility period depends on the plate thickness and the refractive indices of the plate and the surrounding medium. Plotting the phase change versus incident angle or counting the visibility repetition in an incident-angle interval provides, for a given plate thickness, the refractive index of the plate very accurately. It is shown here that the refractive index of a plate can be determined without knowing the plate thickness. Therefore, the technique can be utilized for measuring plate thickness with high precision. In addition, by installing a plate with known refractive index in a rectangular cell filled with a liquid and following the described procedures, the refractive index of the liquid is obtained. The technique is applied to measure the refractive indices of a glass slide, distilled water, and ethanol. The potential and merits of the technique are also discussed.

  15. The structural and optical properties of type III human collagen biosynthetic corneal substitutes

    PubMed Central

    Hayes, Sally; Lewis, Phillip; Islam, M. Mirazul; Doutch, James; Sorensen, Thomas; White, Tomas; Griffith, May; Meek, Keith M.

    2015-01-01

    The structural and optical properties of clinically biocompatible, cell-free hydrogels comprised of synthetically cross-linked and moulded recombinant human collagen type III (RHCIII) with and without the incorporation of 2-methacryloyloxyethyl phosphorylcholine (MPC) were assessed using transmission electron microscopy (TEM), X-ray scattering, spectroscopy and refractometry. These findings were examined alongside similarly obtained data from 21 human donor corneas. TEM demonstrated the presence of loosely bundled aggregates of fine collagen filaments within both RHCIII and RHCIII-MPC implants, which X-ray scattering showed to lack D-banding and be preferentially aligned in a uniaxial orientation throughout. This arrangement differs from the predominantly biaxial alignment of collagen fibrils that exists in the human cornea. By virtue of their high water content (90%), very fine collagen filaments (2–9 nm) and lack of cells, the collagen hydrogels were found to transmit almost all incident light in the visible spectrum. They also transmitted a large proportion of UV light compared to the cornea which acts as an effective UV filter. Patients implanted with these hydrogels should be cautious about UV exposure prior to regrowth of the epithelium and in-growth of corneal cells into the implants. PMID:26159106

  16. Ultraviolet refractometry using field-based light scattering spectroscopy

    PubMed Central

    Fu, Dan; Choi, Wonshik; Sung, Yongjin; Oh, Seungeun; Yaqoob, Zahid; Park, YongKeun; Dasari, Ramachandra R.; Feld, Michael S.

    2010-01-01

    Accurate refractive index measurement in the deep ultraviolet (UV) range is important for the separate quantification of biomolecules such as proteins and DNA in biology. This task is demanding and has not been fully exploited so far. Here we report a new method of measuring refractive index using field-based light scattering spectroscopy, which is applicable to any wavelength range and suitable for both solutions and homogenous objects with well-defined shape such as microspheres. The angular scattering distribution of single microspheres immersed in homogeneous media is measured over the wavelength range 260 to 315 nm using quantitative phase microscopy. By least square fitting the observed scattering distribution with Mie scattering theory, the refractive index of either the sphere or the immersion medium can be determined provided that one is known a priori. Using this method, we have measured the refractive index dispersion of SiO2 spheres and bovine serum albumin (BSA) solutions in the deep UV region. Specific refractive index increments of BSA are also extracted. Typical accuracy of the present refractive index technique is ≤0.003. The precision of refractive index measurements is ≤0.002 and that of specific refractive index increment determination is ≤0.01 mL/g. PMID:20372622

  17. Tamm-plasmon and surface-plasmon hybrid-mode based refractometry in photonic bandgap structures.

    PubMed

    Das, Ritwick; Srivastava, Triranjita; Jha, Rajan

    2014-02-15

    The transverse magnetic (TM) polarized hybrid modes formed as a consequence of coupling between Tamm plasmon polariton (TM-TPP) mode and surface plasmon polariton (SPP) mode exhibit interesting dispersive features for realizing a highly sensitive and accurate surface plasmon resonance (SPR) sensor. We found that the TM-TPP modes, formed at the interface of distributed Bragg reflector and metal, are strongly dispersive as compared to SPP modes at optical frequencies. This causes an appreciably narrow interaction bandwidth between TM-TPP and SPP modes, which leads to highly accurate sensing. In addition, appropriate tailoring of dispersion characteristics of TM-TPP as well as SPP modes could ensure high sensitivity of a novel SPR platform. By suitably designing the Au/TiO₂/SiO₂-based geometry, we propose a TM-TPP/SPP hybrid-mode sensor and achieve a sensitivity ≥900  nm/RIU with high detection accuracy (≥30  μm⁻¹) for analyte refractive indices varying between 1.330 and 1.345 in 600-700 nm wavelength range. The possibility to achieve desired dispersive behavior in any spectral band makes the sensing configuration an extremely attractive candidate to design sensors depending on the availability of optical sources.

  18. Online size-exclusion high-performance liquid chromatography light scattering and differential refractometry methods to determine degree of polymer conjugation to proteins and protein-protein or protein-ligand association states.

    PubMed

    Kendrick, B S; Kerwin, B A; Chang, B S; Philo, J S

    2001-12-15

    Characterizing the solution structure of protein-polymer conjugates and protein-ligand interactions is important in fields such as biotechnology and biochemistry. Size-exclusion high-performance liquid chromatography with online classical light scattering (LS), refractive index (RI), and UV detection offers a powerful tool in such characterization. Novel methods are presented utilizing LS, RI, and UV signals to rapidly determine the degree of conjugation and the molecular mass of the protein conjugate. Baseline resolution of the chromatographic peaks is not required; peaks need only be sufficiently separated to represent relatively pure fractions. An improved technique for determining the polypeptide-only mass of protein conjugates is also described. These techniques are applied to determining the degree of erythropoietin glycosylation, the degree of polyethylene glycol conjugation to RNase A and brain-derived neurotrophic factor, and the solution association states of these molecules. Calibration methods for the RI, UV, and LS detectors will also be addressed, as well as online methods to determine protein extinction coefficients and dn/dc values both unconjugated and conjugated protein molecules. (c)2001 Elsevier Science.

  19. An evaluation of Brix refractometry instruments for measurement of colostrum quality in dairy cattle.

    PubMed

    Bielmann, V; Gillan, J; Perkins, N R; Skidmore, A L; Godden, S; Leslie, K E

    2010-08-01

    Acquisition of high quality colostrum is an important factor influencing neonatal calf health. Many methods have been used to assess the Ig concentration of colostrum; however, improved, validated evaluation tools are needed. The aims of this study were to evaluate both optical and digital Brix refractometer instruments for the measurement of Ig concentration of colostrum as compared with the gold standard radial immunodiffusion assay laboratory assessment and to determine the correlation between Ig measurements taken from fresh and frozen colostrum samples for both Brix refractometer instruments. This research was completed using 288 colostrum samples from 3 different farms. It was concluded that the optical and digital Brix refractometers were highly correlated for both fresh and frozen samples (r=0.98 and r=0.97, respectively). Correlation between both refractometer instruments for fresh and frozen samples and the gold standard radial immunodiffusion assay were determined to be very similar, with a correlation coefficient between 0.71 and 0.74. Both instruments exhibited excellent test characteristics, indicating an appropriate cut-off point of 22% Brix score for the identification of good quality colostrum. Copyright (c) 2010 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  20. Comparison of in vitro tests for evaluation of passive transfer of immunoglobulins in giraffe (Giraffa camelopardalis).

    PubMed

    Miller, M; Coville, B; Abou-Madi, N; Olsen, J

    1999-03-01

    Serum samples from captive giraffe (Giraffa camelopardalis) were tested to assess passive transfer of immunoglobulins using in vitro methods developed for domestic ruminants. Estimated immunoglobulin levels were compared using five tests (protein electrophoresis, total protein refractometry, zinc sulfate turbidity, glutaraldehyde coagulation, and sodium sulfite turbidity). A linear relationship was observed among total protein, gamma globulin (electrophoretic measurement), and immunoglobulin level based on spectrophotometric measurement of zinc sulfate turbidity. Nonquantitative assays also demonstrated statistical correlation with the quantitative methods. Using criteria similar to those established for domestic species, cutoff values for failure of passive transfer (FPT) were established for these tests in neonatal giraffe: 1) total protein <6.0 g/dl; 2) gamma globulin < 0.5 g/dl; 3) estimated immunoglobulin level < 1,000 mg/dl (zinc sulfate turbidity); 4) glutaraldehyde coagulation test negative; or 5) no visually detectable turbidity in 16% sodium sulfite or Bova-S negative. Retrospective examination of the medical histories showed a strong statistical association between animals designated as having FPT and those that were removed from their dams based on clinical assessment to be hand-reared. Application of these tests in the field should allow earlier detection and intervention for FPT in neonatal giraffe.

  1. A new simple compact refractometer applied to measurements of air density fluctuations

    NASA Astrophysics Data System (ADS)

    Fang, H.; Juncar, P.

    1999-07-01

    We describe a new simple, compact refractometer for air refractive index measurements. It consists of a double plane-plane Fabry Perot interferometer. Both interferometers consisting of Zerodur spacers of thickness of 1 and 100 mm are illuminated independently by the same single mode laser diode. The shorter cavity allows unambiguous identification of the transmission peak of the longer one to which the laser frequency is servo-locked. The refractive index of air is obtained via a heterodyne comparison with a second laser locked to a hyperfine component of the rubidium D2 line. We obtain a resolution of order 10-10 and accuracy of a few times 10-8. The metrological characteristics of the interferometer in vacuum are presented. Initial results for refractive index measurements agree with values calculated using the revised Edlen formulas. We also describe how this refractometer is used to measure variations of the density of air and their correlation with changes of refractive index of air. The density of air is used to make buoyancy corrections when comparing mass standards of different volume. Our preliminary results indicate that the values of air density determined by refractometry agree with those calculated using the Comité International des Poids et Mesures formula, which is based on measurements of temperature, pressure, moisture content, and CO2 concentration.

  2. Contact lens material characteristics associated with hydrogel lens dehydration.

    PubMed

    Ramamoorthy, Padmapriya; Sinnott, Loraine T; Nichols, Jason J

    2010-03-01

    To determine the association between material dehydration and hydrogel contact lens material characteristics, including water content and ionicity. Water content and refractive index data were derived from automated refractometry measurements of worn hydrogel contact lenses of 318 participants in the Contact Lens and Dry Eye Study (CLADES). Dehydration was determined in two ways; as the difference between nominal and measured (1) water content and (2) refractive index. Multiple regression models were used to examine the relation between dehydration and material characteristics, controlling for tear osmolality. The overall measured and nominal water content values were 52.58 +/- 7.49% and 56.88 +/- 7.81% respectively, while the measured and nominal refractive indices were 1.429 +/- 0.015 and 1.410 +/- 0.017. High water content and ionic hydrogel lens materials were associated with greater dehydration (p < 0.0001 for both) than low water content and non-ionic materials. When dehydration was assessed as the difference in refractive index, only high water content was associated with dehydration (p < 0.0001). High water content and ionic characteristics of hydrogel lens materials are associated with hydrogel lens dehydration, with the former being more strongly associated. Such dehydration changes could in turn lead to important clinical ramifications such as reduced oxygen transmissibility, greater lens adherence and reduced tear exchange.

  3. Report on twisted nematic and supertwisted nematic device characterization program

    NASA Technical Reports Server (NTRS)

    1995-01-01

    In this study we measured the optical characteristics of normally white twisted nematic (NWTN) and super twisted nematic (STN ) cells. Though no dynamic computer model was available, the static observations were compared with computer simulated behavior. The measurements were taken as a function of both viewing angle and applied voltage and included in the static case not only luminance but also contrast ratio and chromaticity . We employed the computer model Twist Cell Optics, developed at Kent State in conjunction with this study, and whose optical modeling foundation, Iike the ViDEOS program, is the 4 x 4 matrix method of Berreman. In order to resolve discrepancies between the experimental and modeled data the optical parameters of the individual cell components, where not known, were determined using refractometry, profilometry, and various forms of ellipsometry. The resulting agreement between experiment and model is quite good due primarily to a better understanding of the structure and optics of dichroic sheet polarizers. A description of the model and test cells employed are given in section 2. Section 3 contains the experimental data gathered and section 4 gives examples of the fit between model and experiment. Also included with this report are a pair of papers which resulted from the research and which detail the polarizer properties and some of the cell characterization methods.

  4. Cystic fibrosis airway secretions exhibit mucin hyperconcentration and increased osmotic pressure

    PubMed Central

    Henderson, Ashley G.; Ehre, Camille; Button, Brian; Abdullah, Lubna H.; Cai, Li-Heng; Leigh, Margaret W.; DeMaria, Genevieve C.; Matsui, Hiro; Donaldson, Scott H.; Davis, C. William; Sheehan, John K.; Boucher, Richard C.; Kesimer, Mehmet

    2014-01-01

    The pathogenesis of mucoinfective lung disease in cystic fibrosis (CF) patients likely involves poor mucus clearance. A recent model of mucus clearance predicts that mucus flow depends on the relative mucin concentration of the mucus layer compared with that of the periciliary layer; however, mucin concentrations have been difficult to measure in CF secretions. Here, we have shown that the concentration of mucin in CF sputum is low when measured by immunologically based techniques, and mass spectrometric analyses of CF mucins revealed mucin cleavage at antibody recognition sites. Using physical size exclusion chromatography/differential refractometry (SEC/dRI) techniques, we determined that mucin concentrations in CF secretions were higher than those in normal secretions. Measurements of partial osmotic pressures revealed that the partial osmotic pressure of CF sputum and the retained mucus in excised CF lungs were substantially greater than the partial osmotic pressure of normal secretions. Our data reveal that mucin concentration cannot be accurately measured immunologically in proteolytically active CF secretions; mucins are hyperconcentrated in CF secretions; and CF secretion osmotic pressures predict mucus layer–dependent osmotic compression of the periciliary liquid layer in CF lungs. Consequently, mucin hypersecretion likely produces mucus stasis, which contributes to key infectious and inflammatory components of CF lung disease. PMID:24892808

  5. Comparison between refractometer and retinoscopy in determining refractive errors in children--false doubt.

    PubMed

    Pokupec, Rajko; Mrazovac, Danijela; Popović-Suić, Smiljka; Mrazovac, Visnja; Kordić, Rajko; Petricek, Igor

    2013-04-01

    Early detection of a refractive error and its correction are extremely important for the prevention of amblyopia (poor vision). The golden standard in the detection of refractive errors is retinoscopy--a method where the pupils are dilated in order to exclude accomodation. This results in a more accurate measurement of a refractive error. Automatic computer refractometer is also in use. The study included 30 patients, 15 boys, 15 girls aged 4-16. The first examination was conducted with refractometer on narrow pupils. Retinoscopy, followed by another examination with refractometer was performed on pupils dilated with mydriatic drops administered 3 times. The results obtained with three methods were compared. They indicate that in narrow pupils the autorefractometer revealed an increased diopter value in nearsightedness (myopia), the minus overcorrection, whereas findings obtained with retinoscopy and autorefractometer in mydriasis cycloplegia, were much more accurate. The results were statistically processed, which confirmed the differences between obtained measurements. These findings are consistent with the results of studies conducted by other authors. Automatic refractometry on narrow pupils has proven to be a method for detection of refractive errors in children. However, the exact value of the refractive error is obtained only in mydriasis--with retinoscopy or an automatic refractometer on dilated pupils.

  6. Comparison of a digital and an optical analogue hand-held refractometer for the measurement of canine urine specific gravity.

    PubMed

    Paris, J K; Bennett, A D; Dodkin, S J; Gunn-Moore, D A

    2012-05-05

    Urine specific gravity (USG) is used clinically as a measure of urine concentration, and is routinely assessed by refractometry. A comparison between optical analogue and digital refractometers for evaluation of canine urine has not been reported. The aim of this study was to compare a digital and an optical analogue hand-held refractometer for the measurement of canine USG, and to assess correlation with urine osmolality. Prospective study. Free-catch urine samples were collected from 285 hospitalised adult dogs, and paired USG readings were obtained with a digital and an optical analogue refractometer. In 50 dogs, urine osmolality was also measured using a freezing point depression osmometer. There was a small but statistically significant difference between the two refractometers (P<0.001), with the optical analogue refractometer reading higher than the digital refractometer (mean difference 0.0006, sd 0.0012). Paired refractometer measurements varied by <0.002 in 91.5 per cent of cases. The optical analogue and digital refractometer readings showed excellent correlation with osmolality (r=0.980 and r=0.977, respectively, P<0.001 in both cases). Despite statistical significance, the difference between the two refractometers is unlikely to be clinically significant. Both instruments provide an accurate assessment of USG in dogs.

  7. Monitoring the Erosion of Hydrolytically-Degradable Nanogels via Multiangle Light Scattering Coupled to Asymmetrical Flow Field-Flow Fractionation

    PubMed Central

    Smith, Michael H.; South, Antoinette B.; Gaulding, Jeffrey C.; Lyon, L. Andrew

    2009-01-01

    We describe the synthesis and characterization of degradable nanogels that display bulk erosion under physiologic conditions (pH = 7.4, 37 °C). Erodible poly(N-isopropylmethacrylamide) nanogels were synthesized by copolymerization with N,O-(dimethacryloyl)hydroxylamine, a cross-linker previously used in the preparation of non-toxic and biodegradable bulk hydrogels. To monitor particle degradation, we employed multiangle light scattering and differential refractometry detection following asymmetrical flow field-flow fractionation. This approach allowed the detection of changes in nanogel molar mass and topology as a function of both temperature and pH. Particle erosion was evident from both an increase in nanogel swelling and a decrease in scattering intensity as a function of time. Following these analyses, the samples were recovered for subsequent characterization by direct particle tracking, which yields hydrodynamic size measurements and enables number density determination. Additionally, we confirmed the conservation of nanogel stimuli-responsivity through turbidity measurements. Thus, we have demonstrated the synthesis of degradable nanogels that erode under conditions and on timescales that are relevant for many drug delivery applications. The combined separation and light scattering detection method is demonstrated to be a versatile means to monitor erosion and should also find applicability in the characterization of other degradable particle constructs. PMID:20000662

  8. Weathering Patterns of Ignitable Liquids with the Advanced Distillation Curve Method

    PubMed Central

    Bruno, Thomas J; Allen, Samuel

    2013-01-01

    One can take advantage of the striking similarity of ignitable liquid vaporization (or weathering) patterns and the separation observed during distillation to predict the composition of residual compounds in fire debris. This is done with the advanced distillation curve (ADC) metrology, which separates a complex fluid by distillation into fractions that are sampled, and for which thermodynamically consistent temperatures are measured at atmospheric pressure. The collected sample fractions can be analyzed by any method that is appropriate. Analytical methods we have applied include gas chromatography (with flame ionization, mass spectrometric and sulfur chemiluminescence detection), thin layer chromatography, FTIR, Karl Fischer coulombic titrimetry, refractometry, corrosivity analysis, neutron activation analysis and cold neutron prompt gamma activation analysis. We have applied this method on product streams such as finished fuels (gasoline, diesel fuels, aviation fuels, rocket propellants), crude oils (including a crude oil made from swine manure) and waste oils streams (used automotive and transformer oils). In this paper, we present results on a variety of ignitable liquids that are not commodity fuels, chosen from the Ignitable Liquids Reference Collection (ILRC). These measurements are assembled into a preliminary database. From this selection, we discuss the significance and forensic application of the temperature data grid and the composition explicit data channel of the ADC. PMID:26401423

  9. Weathering Patterns of Ignitable Liquids with the Advanced Distillation Curve Method.

    PubMed

    Bruno, Thomas J; Allen, Samuel

    2013-01-01

    One can take advantage of the striking similarity of ignitable liquid vaporization (or weathering) patterns and the separation observed during distillation to predict the composition of residual compounds in fire debris. This is done with the advanced distillation curve (ADC) metrology, which separates a complex fluid by distillation into fractions that are sampled, and for which thermodynamically consistent temperatures are measured at atmospheric pressure. The collected sample fractions can be analyzed by any method that is appropriate. Analytical methods we have applied include gas chromatography (with flame ionization, mass spectrometric and sulfur chemiluminescence detection), thin layer chromatography, FTIR, Karl Fischer coulombic titrimetry, refractometry, corrosivity analysis, neutron activation analysis and cold neutron prompt gamma activation analysis. We have applied this method on product streams such as finished fuels (gasoline, diesel fuels, aviation fuels, rocket propellants), crude oils (including a crude oil made from swine manure) and waste oils streams (used automotive and transformer oils). In this paper, we present results on a variety of ignitable liquids that are not commodity fuels, chosen from the Ignitable Liquids Reference Collection (ILRC). These measurements are assembled into a preliminary database. From this selection, we discuss the significance and forensic application of the temperature data grid and the composition explicit data channel of the ADC.

  10. Comparative study of quantitative phase imaging techniques for refractometry of optical fibers

    NASA Astrophysics Data System (ADS)

    de Dorlodot, Bertrand; Bélanger, Erik; Bérubé, Jean-Philippe; Vallée, Réal; Marquet, Pierre

    2018-02-01

    The refractive index difference profile of optical fibers is the key design parameter because it determines, among other properties, the insertion losses and propagating modes. Therefore, an accurate refractive index profiling method is of paramount importance to their development and optimization. Quantitative phase imaging (QPI) is one of the available tools to retrieve structural characteristics of optical fibers, including the refractive index difference profile. Having the advantage of being non-destructive, several different QPI methods have been developed over the last decades. Here, we present a comparative study of three different available QPI techniques, namely the transport-of-intensity equation, quadriwave lateral shearing interferometry and digital holographic microscopy. To assess the accuracy and precision of those QPI techniques, quantitative phase images of the core of a well-characterized optical fiber have been retrieved for each of them and a robust image processing procedure has been applied in order to retrieve their refractive index difference profiles. As a result, even if the raw images for all the three QPI methods were suffering from different shortcomings, our robust automated image-processing pipeline successfully corrected these. After this treatment, all three QPI techniques yielded accurate, reliable and mutually consistent refractive index difference profiles in agreement with the accuracy and precision of the refracted near-field benchmark measurement.

  11. Cinematic Characterization of Convected Coherent Structures Within an Continuous Flow Z-Pinch

    NASA Astrophysics Data System (ADS)

    Underwood, Thomas; Rodriguez, Jesse; Loebner, Keith; Cappelli, Mark

    2017-10-01

    In this study, two separate diagnostics are applied to a plasma jet produced from a coaxial accelerator with characteristic velocities exceeding 105 m/s and timescales of 10 μs. In the first of these, an ultra-high frame rate CMOS camera coupled to a Z-type laser Schlieren apparatus is used to obtain flow-field refractometry data for the continuous flow Z-pinch formed within the plasma deflagration jet. The 10 MHz frame rate for 256 consecutive frames provides high temporal resolution, enabling turbulent fluctuations and plasma instabilities to be visualized over the course of a single pulse. The unique advantage of this diagnostic is its ability to simultaneously resolve both structural and temporal evolution of instabilities and density gradients within the flow. To allow for a more meaningful statistical analysis of the resulting wave motion, a multiple B-dot probe array was constructed and calibrated to operate over a broadband frequency range up to 100 MHz. The resulting probe measurements are incorporated into a wavelet analysis to uncover the dispersion relation of recorded wave motion and furthermore uncover instability growth rates. Finally these results are compared with theoretical growth rate estimates to identify underlying physics. This work is supported by the U.S. Department of Energy Stewardship Science Academic Program in addition to the National Defense Science Engineering Graduate Fellowship.

  12. Intracellular subsurface imaging using a hybrid shear-force feedback/scanning quantitative phase microscopy technique

    NASA Astrophysics Data System (ADS)

    Edward, Kert

    Quantitative phase microscopy (QPM) allows for the imaging of translucent or transparent biological specimens without the need for exogenous contrast agents. This technique is usually applied towards the investigation of simple cells such as red blood cells which are typically enucleated and can be considered to be homogenous. However, most biological cells are nucleated and contain other interesting intracellular organelles. It has been established that the physical characteristics of certain subsurface structures such as the shape and roughness of the nucleus is well correlated with onset and progress of pathological conditions such as cancer. Although the acquired quantitative phase information of biological cells contains surface information as well as coupled subsurface information, the latter has been ignored up until now. A novel scanning quantitative phase imaging system unencumbered by 2pi ambiguities is hereby presented. This system is incorporated into a shear-force feedback scheme which allows for simultaneous phase and topography determination. It will be shown how subsequent image processing of these two data sets allows for the extraction of the subsurface component in the phase data and in vivo cell refractometry studies. Both fabricated samples and biological cells ranging from rat fibroblast cells to malaria infected human erythrocytes were investigated as part of this research. The results correlate quite well with that obtained via other microscopy techniques.

  13. Role of intraocular lens parameters in visual rehabilitation of patients after extracapsular cataract extraction

    NASA Astrophysics Data System (ADS)

    Bakutkin, Valery V.; Galanzha, Vladimir A.

    2001-01-01

    The main method of cataract treatment is micro surgical removing of the opaque lens from the eye with implantation of an intra ocular lens. We performed the comparative study of using various IOL models differing in its materials, index of refraction, spectral properties, configuration, shape, size and other features. Before and after the IOL implantation we performed the following test: visual acuity measuring, refractometry, keratometry, laser interferometric retinometry, color perception assessment, digital photo- and videorecording of the eye with image processing and some others. We found a number of correlations between the IOL properties and some characteristics of the patient's vision. The decentration of the IOL optical part more than 1,5 mm conduced to the non-corneal astigmatism and the prismatic effect. A small diameter of the IOL optical part and high index of refraction promotes to the appearance of the optical aberrations. Leucosapphire IOLs revealed the high degree of light reflection and the minimal adhesive ability of the IOL surface. Leucosapphire IOL revealed the high degree of light reflection and the minimal adhesive ability of the IOL surface. PMMA IOL revealed the low reflective power and the high adhesive ability. The best color vision was revealed in patients with PMMA IOL with an additional compound absorbing not only UV light but also short-wave blue light.

  14. Prediction of parenteral nutrition osmolarity by digital refractometry.

    PubMed

    Chang, Wei-Kuo; Yeh, Ming-Kung

    2011-05-01

    Infusion of high-osmolarity parenteral nutrition (PN) formulations into a peripheral vein will damage the vessel. In this study, the authors developed a refractometric method to predict PN formulation osmolarity for patients receiving PN. Nutrients in PN formulations were prepared for Brix value and osmolality measurement. Brix value and osmolality measurement of the dextrose, amino acids, and electrolytes were used to evaluate the limiting factor of PN osmolarity prediction. A best-fit equation was generated to predict PN osmolarity (mOsm/L): 81.05 × Brix value--116.33 (R(2) > 0.99). To validate the PN osmolarity prediction by these 4 equations, a total of 500 PN admixtures were tested. The authors found strong linear relationships between the Brix values and the osmolality measurement of dextrose (R(2) = 0.97), amino acids (R(2) = 0.99), and electrolytes (R(2) > 0.96). When PN-measured osmolality was between 600 and 900 mOsm/kg, approximately 43%, 29%, 43%, and 0% of the predicted osmolarity obtained by equations 1, 2, 3, and 4 were outside the acceptable 90% to 110% confidence interval range, respectively. When measured osmolality was between 900 and 1,500 mOsm/kg, 31%, 100%, 85%, and 15% of the predicted osmolarity by equations 1, 2, 3, and 4 were outside the acceptable 90% to 110% confidence interval range, respectively. The refractive method permits accurate PN osmolarity prediction and reasonable quality assurance before PN formulation administration.

  15. Nectar sampling for prairie and oak savanna butterfly restoration1

    PubMed Central

    Arnold, Paige M.; Michaels, Helen J.

    2017-01-01

    Premise of the study: Understanding floral resources is vital for restoring pollinators in habitats affected by anthropogenic development and climate change. As the primary adult food, nectar can limit butterfly longevity and reproduction. For pollinator restoration, it would therefore be useful to examine nectar resources. However, because many flowers preferred by butterflies are too small for microcapillary sampling and the potential for nectar contamination can make accurate measurement difficult, we developed a modified centrifugation method to extract and separate nectar and pollen. Methods: We sampled nectar from 19 forbs using a glass wool filter to exclude potentially contaminating pollen during centrifugation. To minimize costs, we measured sugar concentration by refractometry and simple ninhydrin tests for amino acids and improved test accuracy by subsequent image analysis. Artificial nectars were used to verify the new techniques. Results: This method eliminated pollen from samples, while only slightly increasing sugar concentrations. Some amino acids were lost during centrifugation, but only samples with high concentrations exhibited substantial loss. We found significant differences in nectar quality among species, as well as an unexpected inverse relationship between amino acid and sugar concentrations. Discussion: This modified centrifugation technique is an efficient, less damaging, inexpensive approach for collecting nectar from small flowers while eliminating pollen contamination, and will facilitate restoration of declining pollinators and thereby the plants they service. PMID:28690931

  16. Bio-ethanol production from wet coffee processing waste in Ethiopia.

    PubMed

    Woldesenbet, Asrat Gebremariam; Woldeyes, Belay; Chandravanshi, Bhagwan Singh

    2016-01-01

    Large amounts of coffee residues are generated from coffee processing plants in Ethiopia. These residues are toxic and possess serious environmental problems following the direct discharge into the nearby water bodies which cause serious environmental and health problems. This study was aimed to quantify wet coffee processing waste and estimate its bio-ethanol production. The study showed that the wastes are potential environmental problems and cause water pollution due to high organic component and acidic nature. The waste was hydrolyzed by dilute H 2 SO 4 (0.2, 0.4, 0.6, 0.8 and 1 M) and distilled water. Total sugar content of the sample was determined titrimetrically and refractometry. Maximum value (90%) was obtained from hydrolysis by 0.4 M H 2 SO 4 . Ethanol production was monitored by gas chromatography. The optimum yield of ethanol (78%) was obtained from the sample hydrolyzed by 0.4 M H 2 SO 4 for 1 h at hydrolysis temperature of 100 °C and after fermentation for 24 h and initial pH of 4.5. Based on the data, it was concluded that reuse of the main coffee industry wastes is of significant importance from environmental and economical view points. In conclusion, this study has proposed to utilize the wet coffee processing waste to produce bio-ethanol which provides the alternative energy source from waste biomass and solves the environmental waste disposal as well as human health problem.

  17. Inertial fusion program and national laser users facility program

    NASA Astrophysics Data System (ADS)

    1995-01-01

    This is the 1994 annual report for the University of Rochester, Laboratory for Laser Energetics. The report is presented as a series of research type reports. The titles emphasize the breadth of work carried out. They are: stability analysis of unsteady ablation fronts; characterization of laser-produced plasma density profiles using grid image refractometry; transport and sound waves in plasmas with light and heavy ions; three-halves-harmonic radiation from long-scale-length plasmas revisited; OMEGA upgrade status report; target imaging and backlighting diagnosis; effect of electron collisions on ion-acoustic waves and heat flow; particle-in-cell code simulations of the interaction of gaussian ultrashort laser pulses with targets of varying initial scale lengths; characterization of thick cryogenic fuel layers: compensation for the lens effect using convergent beam interferometry; compact, multijoule-output, Nd:Glass, large-aperture ring amplifier; atomic force microscopy observation of water-induced morphological changes in Y2O3 monolayer coatings; observation of longitudinal acceleration of electrons born in a high-intensity laser focus; spatial intensity nonuniformities of an OMEGA beam due to nonlinear beam propagation; calculated X-ray backlighting images of mixed imploded targets; evaluation of cosmic rays for use in the monitoring of the MEDUSA scintillator-photomultiplier diagnostic array; highly efficient second-harmonic generation of ultra-intense Nd:Glass laser pulses multiple cutoff wave numbers of the ablative Rayleigh-Taylor instability; ultrafast, all-silicon light modulator; angular dependence of the stimulated Brillouin scattering in homogeneous plasma; and femtosecond excited-state dynamics of a conjugated ladder polymer.

  18. Determining the solution conformational entropy of oligosaccharides by SEC with on-line viscometry detection.

    PubMed

    Morris, Mallory J; Striegel, André M

    2014-06-15

    Introduced here is a method for determining the solution conformational entropy of oligosaccharides (-ΔS) that relies on the on-line coupling of size-exclusion chromatography (SEC), an entropically-controlled separation technique, and differential viscometry (VISC). Results from this SEC/VISC method were compared, for the same injections of the same sample dissolutions and under identical solvent/temperature conditions, to results from a benchmark SEC/differential refractometry (SEC/DRI) method which has been applied successfully over the last decade to determining -ΔS of a variety of mono-, di-, and oligosaccharides. The accuracy (as compared to SEC/DRI) and precision of SEC/VISC were found to be excellent, as was the sensitivity of the viscometer in the oligomeric region. The experiments presented here contrast three sets of (1→4)-β-d-oligosaccharides, namely manno-, cello-, and N-acetylchitooligosaccharides of degree of polymerization (DP) 2 through 6. For each series, the dependence of -ΔS on DP was found to be monotonic while, between series, differences at each DP could be ascribed to either the additional degrees of freedom imparted by large, multi-atomic substituent groups, or to the presence or absence of additional intramolecular hydrogen bonds, depending on the axial versus equatorial arrangement of particular hydroxyl groups. An hypothesis is advanced to explain the unexpectedly high sensitivity of viscometric detection for low-molar-mass analytes. The method presented can be extended to the analysis of oligosaccharides other than those studied here. Published by Elsevier Ltd.

  19. HEMATOLOGY AND PLASMA CHEMISTRY OF THE PLOUGHSHARE TORTOISE (ASTROCHELYS YNIPHORA) IN A CAPTIVE BREEDING PROGRAM.

    PubMed

    López, Javier; Waters, Michael; Routh, Andrew; Rakotonanahary, Tsanta F; Woolaver, Lance; Thomasson, Ann; Holmes, Emma; Steinmetz, Hanspeter W

    2017-03-01

    Blood samples from 172 captive and 40 wild, healthy, juvenile and adult, ploughshare tortoises ( Astrochelys yniphora ) were analyzed to determine hematological and biochemical reference intervals. Hematological analytes included packed cell volume (PCV), white blood cell count (WBC), and WBC differential estimates. Biochemical analysis included total protein measured by photometry (TP) and by refractometry (TPr), albumin (ALB), creatine kinase (CK), aspartate aminotransferase (AST), glutamate dehydrogenase (GLDH), bile acids (BA), calcium (Ca), phosphorus (P), urea (UREA), and uric acid (UA). The jugular vein was identified as the preferred venipuncture site as subcarapacial vein venipuncture resulted in regular hemodilution. In due consideration of small sample sizes in some of the groups studied, adult tortoises had significantly higher plasma GLDH activity and TPr, TP, ALB, BA, and UREA concentrations and significantly lower AST activity and P concentration than juveniles. Captivity had a significant influence in some reference intervals, with captive adults presenting significantly higher WBC, and estimated counts of all white cell types as well as UREA and TPr than wild counterparts. Captive juveniles also showed significantly higher estimated monocyte and lower estimated eosinophil and basophil counts. Although these differences most likely reflect local environmental or dietary differences, without representing pathology or a deviation from the normal, they question the applicability of reference values from captive animals to wild animals and vice versa. Significant sex differences were only observed for PCV and UA. The reported reference intervals may serve as benchmarks for clinical assessment and conservation of this critically endangered species.

  20. Use of the refractometer as a tool to monitor dietary formula concentration in gastric juice.

    PubMed

    Chang, W-K; Chen, M-Z; Chao, Y-C

    2002-12-01

    Critically ill patients do not always tolerate nasogastric tube feeding. Gastric residual volumes are widely used to evaluate feeding tolerance, but controversy exists about what constitutes the residual volume (diet formula or digestive juice). In this paper, we describe the use of the refractometer as a tool to monitor dietary formula concentration in gastric juice and evaluate gastric juice refractometry as a possible clinical application. Brix value (an index of the total solutes in solution) readings for polymeric diet at pH 1, 4, 7 and 8, and at 4 degrees C, 25 degrees C and 37 degrees C, and in fasting gastric juice were determined with a refractometer. We found that distilled water, minerals, and vitamins had low Brix values of 0+/-0, 1.2+/-0.1, and 0.4+/-0.1, respectively. On the other hand, because carbohydrate (17 g/100 ml), protein (5.3 g/100 ml), fat (4.1 g/100 ml), and full-strength polymeric diet had high concentrations of dissolved nutrients, they also had high Brix values (12.1+/-0.6, 6.5+/-0.1, 6.0+/-0.1, and 23.5+/-0.1, respectively). The Brix values of polymeric diet had a linear additive relationship with the diet formula concentration at various pHs, temperatures, and in the gastric juice. Brix value measurement can be used to monitor stomach dietary formula concentration. Such information can be obtained at the bedside and used to evaluate feeding-intolerant patients receiving enteral feeding.

  1. Accommodation-Amplitudes following an Accommodative Lens Refilling Procedure — an in vivo Update

    PubMed Central

    Nishi, Okihiro; Nishi, Yutaro; Chang, S.; Nishi, Kayo

    2014-01-01

    Purpose To investigate whether a newly developed lens refilling procedure can provide some accommodation in monkey eyes and to evaluate the difference in accommodation with different degrees of capsular bag refilling. Setting Jinshikai Medical Foundation, Nishi Eye Hospital, Osaka, Japan. Design Experimental monkey study. Methods Following a central 3–4 mm continuous curvilinear capsulorhexis, phacoemulsification was performed in the usual manner. A novel accommodative membrane intraocular lens for sealing capsular opening was implanted into the capsular bag. Silicone polymers were injected beneath the intraocular lens into the capsular bag through the delivery hole. In three study groups, each with six monkey eyes, the lens capsule was refilled with 0.08 ml corresponding to 65% bag volume, 0.1 ml corresponding to 80% bag volume, and 0.125 ml of silicone polymers corresponding to 100% bag volume, respectively. To calculate the accommodation-amplitudes achieved, automated refractometry was performed before and 1 hour after the topical 4% pilocarpine application before and four weeks after surgery. Results The refilling technique was successful in all monkeys without polymer leakage. Accommodation-amplitudes attained were 2.56 ± 0.74 dioptries (D), 2.42 ± 1.00D, and 2.71 ± 0.63D, respectively, 4 weeks after surgery in the three study groups. Conclusions Using the technique, some accommodation could be obtained in the young monkey eyes. Leakage of the injectable silicone polymer and anterior capsular opacification at least in the visual axis could be avoided. The results suggest that this lens refilling procedure warrants further studies for a possible clinical application. PMID:24461501

  2. Normalization to specific gravity prior to analysis improves information recovery from high resolution mass spectrometry metabolomic profiles of human urine.

    PubMed

    Edmands, William M B; Ferrari, Pietro; Scalbert, Augustin

    2014-11-04

    Extraction of meaningful biological information from urinary metabolomic profiles obtained by liquid-chromatography coupled to mass spectrometry (MS) necessitates the control of unwanted sources of variability associated with large differences in urine sample concentrations. Different methods of normalization either before analysis (preacquisition normalization) through dilution of urine samples to the lowest specific gravity measured by refractometry, or after analysis (postacquisition normalization) to urine volume, specific gravity and median fold change are compared for their capacity to recover lead metabolites for a potential future use as dietary biomarkers. Twenty-four urine samples of 19 subjects from the European Prospective Investigation into Cancer and nutrition (EPIC) cohort were selected based on their high and low/nonconsumption of six polyphenol-rich foods as assessed with a 24 h dietary recall. MS features selected on the basis of minimum discriminant selection criteria were related to each dietary item by means of orthogonal partial least-squares discriminant analysis models. Normalization methods ranked in the following decreasing order when comparing the number of total discriminant MS features recovered to that obtained in the absence of normalization: preacquisition normalization to specific gravity (4.2-fold), postacquisition normalization to specific gravity (2.3-fold), postacquisition median fold change normalization (1.8-fold increase), postacquisition normalization to urinary volume (0.79-fold). A preventative preacquisition normalization based on urine specific gravity was found to be superior to all curative postacquisition normalization methods tested for discovery of MS features discriminant of dietary intake in these urinary metabolomic datasets.

  3. LLE 1994 annual report, October 1993--September 1994

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1995-01-01

    This is the 1994 annual report for the University of Rochester, Laboratory for Laser Energetics. The report is presented as a series of research type reports. The titles emphasize the breadth of work carried out. They are: stability analysis of unsteady ablation fronts; characterization of laser-produced plasma density profiles using grid image refractometry; transport and sound waves in plasmas with light and heavy ions; three-halves-harmonic radiation from long-scale-length plasmas revisited; OMEGA upgrade status report; target imaging and backlighting diagnosis; effect of electron collisions on ion-acoustic waves and heat flow; particle-in-cell code simulations of the interaction of gaussian ultrashort laser pulsesmore » with targets of varying initial scale lengths; characterization of thick cryogenic fuel layers: compensation for the lens effect using convergent beam interferometry; compact, multijoule-output, Nd:Glass, large-aperture ring amplifier; atomic force microscopy observation of water-induced morphological changes in Y{sub 2}O{sub 3} monolayer coatings; observation of longitudinal acceleration of electrons born in a high-intensity laser focus; spatial intensity nonuniformities of an OMEGA beam due to nonlinear beam propagation; calculated X-ray backlighting images of mixed imploded targets; evaluation of cosmic rays for use in the monitoring of the MEDUSA scintillator-photomultiplier diagnostic array; highly efficient second-harmonic generation of ultra-intense Nd:Glass laser pulses multiple cutoff wave numbers of the ablative Rayleigh-Taylor instability; ultrafast, all-silicon light modulator; angular dependence of the stimulated Brillouin scattering in homogeneous plasma; femtosecond excited-state dynamics of a conjugated ladder polymer.« less

  4. Macular Pigment Optical Density and Ocular Pulse Amplitude in Subjects with Different Axial Lengths and Refractive Errors.

    PubMed

    Czepita, Maciej; Karczewicz, Danuta; Safranow, Krzysztof; Czepita, Damian

    2015-06-13

    The purpose of our study was to: (1) investigate the macular pigment optical density (MPOD) and ocular pulse amplitude (OPA) in subjects with different axial lengths (AL) and refractive errors (RE); (2) determine if there is a correlation between MPOD and OPA; and (3) evaluate whether MPOD and OPA depend on intraocular pressure (IOP). This study included 140 eyes of 70 subjects - 17 men and 53 women, aged 18 to 29 years (mean: 22.5 years; SD=2.8). Every examined person underwent a thorough eye examination including: visual acuity, anterior segment and fundus examination, keratometry, auto-refractometry, and MPOD, OPA, AL, and IOP measurements. The obtained results were analyzed statistically using Statistica 10 software. P values of <0.05 were considered statistically significant. The following refractive errors were selected: emmetropia (34 eyes), hyperopia (18 eyes), low myopia (60 eyes), medium myopia (19 eyes), and high myopia (9 eyes). It has been established that the OPA increases with the rise in the spherical equivalents (SE) (Rs=+0.38, P<0.001), while the increase in AL correlates with the decrease of OPA (Rs=-0.40, P<0.001). The increase in IOP correlates with the rise in the OPA (Rs=+0.20, P<0.05). There were no significant correlations between IOP and SE or AL. (1) MPOD is not correlated with the OPA in subjects with different AL and RE; (2) OPA decreases with the rise of AL; (3) OPA decreases with the fall of the SE; and (4) OPA increases with the rise in IOP.

  5. Validity of a portable urine refractometer: the effects of sample freezing.

    PubMed

    Sparks, S Andy; Close, Graeme L

    2013-01-01

    The use of portable urine osmometers is widespread, but no studies have assessed the validity of this measurement technique. Furthermore, it is unclear what effect freezing has on osmolality. One-hundred participants of mean (±SD) age 25.1 ± 7.6 years, height 1.77 ± 0.1 m and weight 77.1 ± 10.8 kg provided single urine samples that were analysed using freeze point depression (FPD) and refractometry (RI). Samples were then frozen at -80°C (n = 81) and thawed prior to re-analysis. Differences between methods and freezing were determined using Wilcoxon's signed rank test. Relationships between measurements were assessed using intraclass correlation coefficients (ICC) and typical error of estimate (TE). Osmolality was lower (P = 0.001) using RI (634.2 ± 339.8 mOsm · kgH2O(-1)) compared with FPD (656.7 ± 334.1 mOsm · kgH2O(-1)) but the TE was trivial (0.17). Freezing significantly reduced mean osmolality using FPD (656.7 ± 341.1 to 606.5 ± 333.4 mOsm · kgH2O(-1); P < 0.001), but samples were still highly related following freezing (ICC, r = 0.979, P < 0.001, CI = 0.993-0.997; TE = 0.15; and r=0.995, P < 0.001, CI = 0.967-0.986; TE = 0.07 for RI and FPD respectively). Despite mean differences between methods and as a result of freezing, such differences are physiologically trivial. Therefore, the use of RI appears to be a valid measurement tool to determine urine osmolality.

  6. Age-Related Changes in Centripetal Ciliary Body Movement Relative to Centripetal Lens Movement in Monkeys

    PubMed Central

    Croft, Mary Ann; McDonald, Jared P.; Nadkarni, Nivedita V.; Lin, Ting-Li; Kaufman, Paul L.

    2009-01-01

    The goal was to determine the age-related changes in accommodative movements of the lens and ciliary body in rhesus monkeys. Varying levels of accommodation were stimulated via the Edinger-Westphal (E-W) nucleus in 26 rhesus monkeys, aged 6-27 years, and the refractive changes were measured by coincidence refractometry. Centripetal ciliary process (CP) and lens movements were measured by computerized image analysis of goniovideographic images. Ultrasound biomicroscopy (UBM) at 50 MHz was used to visualize and measure accommodative forward movements of the ciliary body in relation to age, accommodative amplitude, and centripetal CP and lens movements. At ∼3 diopters of accommodation, the amount of centripetal lens movement required did not significantly change with age (p=0.10; n=18 monkeys); however, the amount of centripetal CP movement required significantly increased with age (p=0.01; n=18 monkeys), while the amount of forward ciliary body movement significantly decreased with age (p=0.007; n=11 monkeys). In the middle-aged animals (12-16.5 years), a greater amount of centripetal CP movement was required to induce a given level of lens movement and thereby a given level of accommodation (p=0.01), compared to the young animals (6-10 yrs). Collectively, the data suggests that, with age, the accommodative system may be attempting to compensate for the loss of forward ciliary body movement by increasing the amount of centripetal CP movement. This, in turn, would allow enough zonular relaxation to achieve the magnitude of centripetal lens movement necessary for a given amplitude of accommodation. PMID:19635475

  7. Surgical intervention and accommodative responses, I: centripetal ciliary body, capsule, and lens movements in rhesus monkeys of various ages.

    PubMed

    Croft, Mary Ann; McDonald, Jared P; James, Rebecca J; Heatley, Gregg A; Lin, Ting-Li; Lütjen-Drecoll, Elke; Kaufman, Paul L

    2008-12-01

    To determine how surgically altering the normal relationship between the lens and the ciliary body in rhesus monkeys affects centripetal ciliary body and lens movement. In 18 rhesus monkey eyes (aged 6-27 years), accommodation was induced before and after surgery by electrical stimulation of the Edinger-Westphal nucleus. Accommodative amplitude was measured by coincidence refractometry. Goniovideography was performed before and after intra- and extracapsular lens extraction (ICLE, ECLE) and anterior regional zonulolysis (ARZ). Centripetal lens/capsule movements, centripetal ciliary process (CP) movements, and circumlental space were measured by computerized image analysis of the goniovideography images. Centripetal accommodative CP and capsule movement increased in velocity and amplitude after, compared with before, ECLE regardless of age (n = 5). The presence of the lens substance retarded capsule movement by approximately 21% in the young eyes and by approximately 62% in the older eyes. Post-ICLE compared with pre-ICLE centripetal accommodative CP movement was dampened in all eyes in which the anterior vitreous was disrupted (n = 7), but not in eyes in which the anterior vitreous was left intact (n = 2). After anterior regional zonulolysis (n = 4), lens position shifted toward the lysed quadrant during accommodation. The presence of the lens substance, capsule zonular attachments, and Wieger's ligament may play a role in centripetal CP movement. The capsule is still capable of centripetal movement in the older eye (although at a reduced capacity) and may have the ability to produce approximately 6 D of accommodation in the presence of a normal, young crystalline lens or a similar surrogate.

  8. The hematology of captive Bobtail lizards (Tiliqua rugosa): blood counts, light microscopy, cytochemistry, and ultrastructure.

    PubMed

    Moller, Cheryl A; Gaál, Tibor; Mills, Jennifer N

    2016-12-01

    Bobtail lizards (Tiliqua rugosa) are native to Australia. The only previous study on the hematology of this species documented just 6 animals. The aims of this study were to characterize the light microscopy, ultrastructure and cytochemistry of blood cells, and evaluate CBCs of captive Bobtail lizards. Over 2 consecutive summers, heparinized venous blood was collected from the ventral coccygeal vein of 46 clinically healthy, captive indoor- or outdoor-housed adult Bobtails. Complete blood cell counts and smear evaluations were performed, and cytochemical stains and transmission electron microscopy were used to further characterize blood cells. The eosinophils of this species were uniformly vacuolated: a unique feature not previously reported in reptiles. Heterophils were the predominant leukocyte, with fewer lymphocytes, azurophilic and nonazurophilic monocytes, occasional eosinophils, and basophils. Thrombocytes were frequently clumped. Slight polychromasia (0-15% of erythrocytes) was typically present. Hemogregarine parasites were seen on some smears. The range of CBC results was often wide. The PCV ranged from 11% to 38%. Total plasma proteins by refractometry were between 3.5 and 7.8 g/dL. Hemoglobin ranged between 2.6 and 12.6 g/dL by the modified hemoglobin-hydroxylamine method. Manual RBC count was 0.35-1.27 × 10 6 /μL, and WBC count was 2.86-22.66 × 10 3 /μL. Bobtail lizards housed outdoors had lower PCVs than indoor-housed animals. Bobtails with hemogregarine infections had lower PCVs than noninfected lizards. Ranges for CBC data were often very wide, influenced by preanalytic and analytic factors. Hemogregarine infection is associated with a decreased PCV, suggesting that some hemogregarine species are pathogenic in this population. © 2016 American Society for Veterinary Clinical Pathology.

  9. From the speed of sound to the speed of light: Ultrasonic Cherenkov refractometry

    NASA Astrophysics Data System (ADS)

    Hallewell, G. D.

    2017-12-01

    Despite its success in the SLD CRID at the SLAC Linear Collider, ultrasonic measurement of Cherenkov radiator refractive index has been less fully exploited in more recent Cherenkov detectors employing gaseous radiators. This is surprising, since it is ideally suited to monitoring hydrostatic variations in refractive index as well as its evolution during the replacement of a light radiator passivation gas (e.g. N2, CO2) with a heavier fluorocarbon (e.g. C4F10[CF4]; mol. wt. 188[88]). The technique exploits the dependence of sound velocity on the molar concentrations of the two components at known temperature and pressure. The SLD barrel CRID used an 87%C5F12/13%N2 blend, mixed before injection into the radiator vessel: blend control based on ultrasonic mixture analysis maintained the β=1 Cherenkov ring angle to a long term variation better than ±0.3%, with refractivity monitored ultrasonically at multiple points within the radiator vessel. Recent advances using microcontroller-based electronics have led to ultrasonic instruments capable of simultaneously measuring gas flow and binary mixture composition in the fluorocarbon evaporative cooling systems of the ATLAS Inner Detector. Sound transit times are measured with multi-MHz transit time clocks in opposite directions in flowing gas for simultaneous measurement of flow rate and sound velocity. Gas composition is evaluated in real-time by comparison with a sound velocity/composition database. Such instruments could be incorporated into new and upgraded gas Cherenkov detectors for radiator gas mixture (and corresponding refractive index) measurement to a precision better than 10-3. They have other applications in binary gas analysis - including in Xenon-based anaesthesia. These possibilities are discussed.

  10. Inability of Open-Field Autorefraction to Eliminate Accommodation in Preschoolers.

    PubMed

    Kara, Caner; Petriçli, İkbal Seza

    2017-09-01

    To evaluate the effectiveness of the Shin-Nippon NVision-K 5001 autorefractometer (Rexxam Co. Ltd., Osaka, Japan) (also branded as the Grand Seiko WR-5100K; Grand Seiko Co. Ltd., Hiroshima, Japan) based on the open-field refractometry principle in refractive measurements of preschool children and to determine its ability to eliminate accommodation adequately. The refractive results of 114 preschool children who presented to the ophthalmology outpatient department for screening were evaluated. The measurements were obtained before and after cycloplegia with the Shin-Nippon NVision-K 5001 autorefractometer and after cycloplegia with retinoscopy, which is the gold standard. The results underwent vectorial transformation to produce the spherical equivalent (M) and two Jackson cross-cylinder (J0 and J45) values. All results were then subjected to statistical analysis. The difference between the measurements was evaluated with repeated measures analysis of variance. Included in the study were 106 preschool children (51 boys and 55 girls). The mean age was 5.3 ± 0.9 years (range: 3 to 6 years). Although statistically significantly more myopic results were obtained with non-cycloplegic measurements using the Shin-Nippon NVision-K 5001 autorefractometer (P < .001), no difference was observed in cylindrical values (P > .05). Cycloplegic J0 measurements were significantly lower (P < .001), but no difference was found between J45 values before and after cycloplegia (P > .05). The Shin-Nippon NVision-K 5001/Grand Seiko WR-5100K open-field autorefractometer seems to be inadequate in eliminating accommodation in childhood. Measurements under cycloplegia continue to be the best method to ensure accurate results. [J Pediatr Ophthalmol Strabismus. 2017;54(5):311-318.]. Copyright 2017, SLACK Incorporated.

  11. SURGICAL INTERVENTION AND ACCOMMODATIVE RESPONSES: I. CENTRIPETAL CILIARY BODY, CAPSULE AND LENS MOVEMENT IN RHESUS MONKEYS OF VARYING AGE

    PubMed Central

    Croft, Mary Ann; Mcdonald, Jared P.; James, Rebecca J.; Heatley, Gregg A.; Lin, Ting-Li; Lütjen-Drecoll, Elke; Kaufman, Paul L.

    2009-01-01

    Purpose To determine how surgically altering the normal relationship between the lens and the ciliary body in rhesus monkeys affects centripetal ciliary body and lens movement. Methods In 18 rhesus monkey eyes (aged 6–27 years), accommodation was induced before and after surgery by electrical stimulation of the Edinger-Westphal (E–W) nucleus. Accommodative amplitude was measured by coincidence refractometry. Goniovideography was performed before and after intra- and extra-capsular lens extraction (ICLE, ECLE) and anterior regional zonulolysis. Centripetal lens/capsule movements, centripetal ciliary process (CP) movements, and circumlental space were measured by computerized image analysis of the goniovideography images. Results Centripetal accommodative CP and capsule movement increased in velocity and amplitude post-ECLE compared to pre-ECLE regardless of age (n=5). The presence of the lens substance retarded capsule movement by ~21% in the young eyes and by ~62% in the older eyes. Post-ICLE compared to pre-ICLE centripetal accommodative CP movement was dampened in all eyes in which the anterior vitreous was disturbed (n=7), but not in eyes in which the anterior vitreous was left intact (n=2). Following anterior regional zonulolysis (n=4), lens position shifted toward the lysed quadrant during accommodation. Conclusions The presence of the lens substance, capsule zonular attachments, and Wiegers ligament may play a role in centripetal CP movement. The capsule is still capable of centripetal movement in the older eye (although at a reduced capacity) and may have the ability to produce ~6 diopters of accommodation in the presence of a normal young crystalline lens or a similar surrogate. PMID:18552393

  12. Tracheobronchial air-liquid interface cell culture: a model for innate mucosal defense of the upper airways?

    PubMed Central

    Kesimer, Mehmet; Kirkham, Sara; Pickles, Raymond J.; Henderson, Ashley G.; Alexis, Neil E.; DeMaria, Genevieve; Knight, David; Thornton, David J.; Sheehan, John K.

    2009-01-01

    Human tracheobronchial epithelial cells grown in air-liquid interface culture have emerged as a powerful tool for the study of airway biology. In this study, we have investigated whether this culture system produces “mucus” with a protein composition similar to that of in vivo, induced airway secretions. Previous compositional studies of mucous secretions have greatly underrepresented the contribution of mucins, which are major structural components of normal mucus. To overcome this limitation, we have used a mass spectrometry-based approach centered on prior separation of the mucins from the majority of the other proteins. Using this approach, we have compared the protein composition of apical secretions (AS) from well-differentiated primary human tracheobronchial cells grown at air-liquid interface and human tracheobronchial normal induced sputum (IS). A total of 186 proteins were identified, 134 from AS and 136 from IS; 84 proteins were common to both secretions, with host defense proteins being predominant. The epithelial mucins MUC1, MUC4, and MUC16 and the gel-forming mucins MUC5B and MUC5AC were identified in both secretions. Refractometry showed that the gel-forming mucins were the major contributors by mass to both secretions. When the composition of the IS was corrected for proteins that were most likely derived from saliva, serum, and migratory cells, there was considerable similarity between the two secretions, in particular, in the category of host defense proteins, which includes the mucins. This shows that the primary cell culture system is an important model for study of aspects of innate defense of the upper airways related specifically to mucus consisting solely of airway cell products. PMID:18931053

  13. Nectar-secreting Floral Stomata in Maxillaria anceps Ames & C. Schweinf. (Orchidaceae)

    PubMed Central

    DAVIES, K. L.; STPICZYŃSKA, M.; GREGG, A.

    2005-01-01

    • Background and Aims Although it was generally assumed that Maxillaria spp. do not produce nectar, in recent years, nectar has been reported for a number of these orchids. Nevertheless, our current understanding of nectary structure and nectar secretion in Maxillaria is based solely on M. coccinea (Jacq.) L.O. Williams ex Hodge, which, since it shows many features characteristic of ornithophilous flowers, is atypical of this largely entomophilous genus. The aim of the present paper is to describe, for the first time, nectar secretion in a presumed entomophilous species of Maxillaria. • Methods The structure of the nectary of M. anceps Ames & C. Schweinf., nectar composition and the process of nectar secretion were investigated using light microscopy, scanning electron microscopy, transmission electron microscopy, histochemistry, refractometry and high performance liquid chromatography. • Key Results and Conclusions Nectar appears as droplets that are exuded by modified stomata borne upon the labellar callus and collects upon the labellum and at the base of the column-foot. Although such stomata are known to occur in a number of angiosperm families, this is the first time for them to be observed in orchids. The callus consists largely of parenchyma with raphides and is supplied by eight to ten collateral bundles. This tissue, together with the single-layered epidermis, seemingly contains terpenoids. During the bud stage, the callus cells contain an organelle complement consistent with secretory cells whereas by day 4 of anthesis, much of the cell is occupied by a vacuole. The nectar is sucrose-dominant but also contains low concentrations of glucose, fructose, free amino acids and possibly terpenoids. The high sugar concentration (approx. 66 %) is consistent with melittophily and may indicate that, like the majority of Maxillaria spp., M. anceps is visited by stingless bees (Meliponini). PMID:15953790

  14. Corneal refractive index-hydration relationship by objective refractometry.

    PubMed

    Patel, Sudi; Alió, Jorge L

    2012-11-01

    To compare an objective (VCH-1) with a manual subjective Abbé refractometer (MSAR) and evaluate the refractive index (RI)-hydration (H) relationship for the corneal stroma. Epithelial and endothelial layers were removed from a fresh postmortem ovine corneal buttons. RI was measured at both surfaces using (i) MSAR then (ii) VCH-1. The sample was weighed, slowly dehydrated under controlled conditions (2 h), and RI measures were repeated. Sample was oven dried (90°C) for 3 d to obtain dry weight and hydration at each episode of RI measurement. Average difference between individual pairs of measurements obtained using the two refractometers (ΔRI) was 0.00071 (standard deviation ± 0.0029, 95% confidence interval ± 0.0058). Root mean square difference between measurements obtained by the refractometers was 0.0024. There was no relationship between ΔRI and the mean of each measurement pair (r = 0.201, n = 40, p = 0.214). Linear regression revealed a significant relationship between RI and reciprocal of H at both surfaces as follows: anterior (i) RI = 1.355 + 0.111/H (r = -0.852, n = 20, p = <0.001), (ii) RI = 1.357 + 0.105/H (r = -0.849, n = 20, p = <0.001) and posterior (i) RI = 1.353 + 0.085/H (r = -0.882, n = 20, p = <0.001), (ii) RI = 1.350 + 0.088/H (r = -0.813, n = 20, p = <0.001). VCH-1 measurements are in good agreement with MSAR. RI at the anterior stroma was consistently higher suggesting hydration is lower by 1.10 units (6%) compared with the posterior stroma. Dehydration increased RI at both surfaces by similar rates. Current hypothetical models are useful for predicting RI from H for the posterior, but not the anterior, stroma.

  15. Use of the Vettest 8008 and refractometry for determination of total protein, albumin, and globulin concentrations in feline effusions.

    PubMed

    Papasouliotis, Kostas; Murphy, Kate; Dodkin, Steve; Torrance, Andy G

    2002-01-01

    Pleural and peritoneal effusion is a common clinical finding in feline practice. Determination of fluid albumin (ALB) and globulin (GLOB) concentrations in addition to total protein (TP) concentration can be helpful in diagnosing or ruling out certain diseases in cats, especially feline infectious peritonitis (FIP). The objective of this study was to compare effusion TP, ALB, and GLOB results obtained by a refractometer and a bench-top dry chemistry analyzer with those results obtained by a reference method. Twenty-six pleural and 14 peritoneal effusion samples were analyzed from 40 cats with various diseases. TP and ALB concentrations were determined by a reference automated wet chemistry analyzer (Kone Specific, Kone Instruments, Espoo, Finland), a bench-top dry chemistry analyzer (Vettest 8008, IDEXX Laboratories Ltd, Chalfont St Peter, UK), and a refractometer (Atago SPR-T2, Atago Co, Tokyo, Japan). GLOB, albumin to globulin (A/G) ratio, and globulins as a percentage of total proteins (GLOB%) were calculated. Results were analyzed by paired t tests, difference plots, and Deming s regression analysis. Correlation coefficients (r) for TP with Vettest versus Kone and refractometer versus Kone methods were.97 and.94, respectively. GLOB and GLOB% values were significantly higher and A/G ratios were significantly lower with Vettest versus Kone methods. Correlation coefficients for ALB, GLOB, GLOB% and A/G ratio with Vettest versus Kone methods were.86,.93,.82, and.73, respectively. Although correlation with other methods was good, the refractometer underestimated TP concentrations in 3 samples. The refractometer is an acceptable method for determination of TP concentration in feline effusions. The Vettest 8008 also is an acceptable method for the determination of TP and ALB concentrations, however, calculated A/G ratios obtained with the Vettest are unacceptable.

  16. Evaluation of a Brix refractometer to estimate serum immunoglobulin G concentration in neonatal dairy calves.

    PubMed

    Deelen, S M; Ollivett, T L; Haines, D M; Leslie, K E

    2014-01-01

    The objective of this study was to evaluate the utility of a digital Brix refractometer for the assessment of success of passive transfer of maternal immunoglobulin compared with the measurement of serum total protein (STP) by refractometry. Blood samples (n = 400) were collected from calves at 3 to 6d of age. Serum IgG concentration was determined by radial immunodiffusion (RID), and STP and percentage Brix (%Brix) were determined using a digital refractometer. The mean IgG concentration was 24.1g/L [standard deviation (SD) ± 10.0] with a range from 2.1 to 59.1g/L. The mean STP concentration was 6.0 g/dL (SD ± 0.8) with a range from 4.4 to 8.8 g/dL. The mean %Brix concentration was 9.2% (SD ± 0.9) with a range of 7.3 to 12.4%. Brix percentage was highly correlated with IgG (r = 0.93). Test characteristics were calculated to assess failure of passive transfer (FPT; serum IgG <10 g/L). The sensitivity and specificity of STP at 5.5 g/dL were 76.3 and 94.4%, respectively. A receiver operating characteristic curve was created to plot the true positive rate against the false positive rate for consecutive %Brix values. The optimal combination of sensitivity (88.9%) and specificity (88.9%) was at 8.4% Brix. Serum total protein was also positively correlated with %Brix (r = 1.00) and IgG (r = 0.93). Dairy producers can successfully monitor their colostrum management and the overall success of passive transfer using a digital Brix refractometer to estimate IgG concentration of colostrum and calf serum. Copyright © 2014 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  17. Nectar-secreting floral stomata in Maxillaria anceps Ames & C. Schweinf. (Orchidaceae).

    PubMed

    Davies, K L; Stpiczyńska, M; Gregg, A

    2005-08-01

    Although it was generally assumed that Maxillaria spp. do not produce nectar, in recent years, nectar has been reported for a number of these orchids. Nevertheless, our current understanding of nectary structure and nectar secretion in Maxillaria is based solely on M. coccinea (Jacq.) L.O. Williams ex Hodge, which, since it shows many features characteristic of ornithophilous flowers, is atypical of this largely entomophilous genus. The aim of the present paper is to describe, for the first time, nectar secretion in a presumed entomophilous species of Maxillaria. The structure of the nectary of M. anceps Ames & C. Schweinf., nectar composition and the process of nectar secretion were investigated using light microscopy, scanning electron microscopy, transmission electron microscopy, histochemistry, refractometry and high performance liquid chromatography. Nectar appears as droplets that are exuded by modified stomata borne upon the labellar callus and collects upon the labellum and at the base of the column-foot. Although such stomata are known to occur in a number of angiosperm families, this is the first time for them to be observed in orchids. The callus consists largely of parenchyma with raphides and is supplied by eight to ten collateral bundles. This tissue, together with the single-layered epidermis, seemingly contains terpenoids. During the bud stage, the callus cells contain an organelle complement consistent with secretory cells whereas by day 4 of anthesis, much of the cell is occupied by a vacuole. The nectar is sucrose-dominant but also contains low concentrations of glucose, fructose, free amino acids and possibly terpenoids. The high sugar concentration (approx. 66 %) is consistent with melittophily and may indicate that, like the majority of Maxillaria spp., M. anceps is visited by stingless bees (Meliponini).

  18. Optofluidic intracavity spectroscopy for spatially, temperature, and wavelength dependent refractometry

    NASA Astrophysics Data System (ADS)

    Kindt, Joel D.

    A microfluidic refractometer was designed based on previous optofluidic intracavity spectroscopy (OFIS) chips utilized to distinguish healthy and cancerous cells. The optofluidic cavity is realized by adding high reflectivity dielectric mirrors to the top and bottom of a microfluidic channel. This creates a plane-plane Fabry-Perot optical cavity in which the resonant wavelengths are highly dependent on the optical path length inside the cavity. Refractometry is a useful method to determine the nature of fluids, including the concentration of a solute in a solvent as well as the temperature of the fluid. Advantages of microfluidic systems are the easy integration with lab-on-chip devices and the need for only small volumes of fluid. The unique abilities of the microfluidic refractometer in this thesis include its spatial, temperature, and wavelength dependence. Spatial dependence of the transmission spectrum is inherent through a spatial filtering process implemented with an optical fiber and microscope objective. A sequence of experimental observations guided the change from using the OFIS chip as a cell discrimination device to a complimentary refractometer. First, it was noted the electrode structure within the microfluidic channel, designed to trap and manipulate biological cells with dielectrophoretic (DEP) forces, caused the resonant wavelengths to blue-shift when the electrodes were energized. This phenomenon is consistent with the negative dn/dT property of water and water-based solutions. Next, it was necessary to develop a method to separate the optical path length into physical path length and refractive index. Air holes were placed near the microfluidic channel to exclusively measure the cavity length with the known refractive index of air. The cavity length was then interpolated across the microfluidic channel, allowing any mechanical changes to be taken into account. After the separation of physical path length and refractive index, it was of interest to characterize the temperature dependent refractive index relationship, n(T), for phosphate buffered saline. Phosphate buffered saline (PBS) is a water-based solution used with our biological cells because it maintains an ion concentration similar to that found in body fluids. The n(T) characterization was performed using a custom-built isothermal apparatus in which the temperature could be controlled. To check for the accuracy of the PBS refractive index measurements, water was also measured and compared with known values in the literature. The literature source of choice has affiliations to NIST and a formulation of refractive index involving temperature and wavelength dependence, two parameters which are necessary for our specialized infrared wavelength range. From the NIST formula, linear approximations were found to be dn/dT = -1.4x10-4 RIU °C-1 and dn/dlambda = -1.5x10-5 RIU nm-1 for water. A comparison with the formulated refractive indices of water indicated the measured values were off. This was attributed to the fact that light penetration into the HfO2/SiO2 dielectric mirrors had not been considered. Once accounted for, the refractive indices of water were consistent with the literature, and the values for PBS are believed to be accurate. A further discovery was the refractive index values at the discrete resonant wavelengths were monotonically decreasing, such that the dn/dlambda slope for water was considerably close to the NIST formula. Thus, n(T,lambda) was characterized for both water and PBS. A refractive index relationship for PBS with spatial, temperature, and wavelength dependence is particularly useful for non-uniform temperature distributions caused by DEP electrodes. First, a maximum temperature can be inferred, which is the desired measurement for cell viability concerns. In addition, a lateral refractive index distribution can be measured to help quantify the gradient index lenses that are formed by the energized electrodes. The non-uniform temperature distribution was also simulated with a finite element analysis software package. This simulated temperature distribution was converted to a refractive index distribution, and focal lengths were calculated for positive and negative gradient index lenses to a smallest possible length of about 10mm.

  19. Is Low-field NMR a Complementary Tool to GC-MS in Quality Control of Essential Oils? A Case Study: Patchouli Essential Oil.

    PubMed

    Krause, Andre; Wu, Yu; Tian, Runtao; van Beek, Teris A

    2018-04-24

    High-field NMR is an expensive and important quality control technique. In recent years, cheaper and simpler low-field NMR has become available as a new quality control technique. In this study, 60 MHz 1 H-NMR was compared with GC-MS and refractometry for the detection of adulteration of essential oils, taking patchouli essential oil as a test case. Patchouli essential oil is frequently adulterated, even today. In total, 75 genuine patchouli essential oils, 10 commercial patchouli essential oils, 10 other essential oils, 17 adulterants, and 1 patchouli essential oil, spiked at 20% with those adulterants, were measured. Visual inspection of the NMR spectra allowed for easy detection of 14 adulterants, while gurjun and copaiba balsams proved difficult and one adulterant could not be detected. NMR spectra of 10 random essential oils differed not only strongly from patchouli essential oil but also from one another, suggesting that fingerprinting by low-field NMR is not limited to patchouli essential oil. Automated chemometric evaluation of NMR spectra was possible by similarity analysis (Mahalanobis distance) based on the integration from 0.1 - 8.1 ppm in 0.01 ppm increments. Good quality patchouli essential oils were recognised as well as 15 of 17 deliberate adulterations. Visual qualitative inspection by GC-MS allowed for the detection of all volatile adulterants. Nonvolatile adulterants, and all but one volatile adulterant, could be detected by semiquantitation. Different chemometric approaches showed satisfactory results. Similarity analyses were difficult with nonvolatile adulterants. Refractive index measurements could detect only 8 of 17 adulterants. Due to advantages such as simplicity, rapidity, reproducibility, and ability to detect nonvolatile adulterants, 60 MHz 1 H-NMR is complimentary to GC-MS for quality control of essential oils. Georg Thieme Verlag KG Stuttgart · New York.

  20. Erosive and cariogenicity potential of pediatric drugs: study of physicochemical parameters

    PubMed Central

    2013-01-01

    Background Pediatric medications may possess a high erosive potential to dental tissues due to the existence of acid components in their formulations. The purpose was to determine the erosive and cariogenic potential of pediatric oral liquid medications through the analysis of their physicochemical properties in vitro. Methods A total of 59 substances were selected from the drug reference list of the National Health Surveillance Agency (ANVISA), which belong to 11 therapeutic classes, as follows: analgesics, non-steroidal anti-inflammatory, corticosteroids, antihistamines, antitussives, bronchodilators, antibacterials, antiparasitics, antiemetics, anticonvulsants and antipsychotics. Measurement of pH was performed by potentiometry, using a digital pH meter. For the Total Titratable Acidity (TTA) chemical assay, a 0.1 N NaOH standard solution was used, which was titrated until drug pH was neutralized. The Total Soluble Solids Contents (TSSC) quantification was carried out by refractometry using Brix scale and the analysis of Total Sugar Content was performed according to Fehling’s method. In addition, it was analyzed the information contained in the drug inserts with regard to the presence of sucrose and type of acid and sweetener added to the formulations. Results All drug classes showed acidic pH, and the lowest mean was found for antipsychotics (2.61 ± 0.08). There was a large variation in the TTA (0.1% - 1.18%) and SST (10.44% - 57.08%) values. High total sugar contents were identified in the antitussives (53.25%) and anticonvulsants (51.75%). As described in the drug inserts, sucrose was added in 47.5% of the formulations, as well as citric acid (39.0%), sodium saccharin (36.4%) and sorbitol (34.8%). Conclusion The drugs analyzed herein showed physicochemical characteristics indicative of a cariogenic and erosive potential on dental tissues. Competent bodies’ strategies should be implemented in order to broaden the knowledge of health professionals, drug manufacturers and general consuming public about the risks from the consumption of medicines potentially harmful to dental tissues. PMID:24325544

  1. Correction of irregular and induced regular corneal astigmatism with toric IOL after posterior segment surgery: a case series.

    PubMed

    Kolozsvári, Bence L; Losonczy, Gergely; Pásztor, Dorottya; Fodor, Mariann

    2017-01-13

    Toric intraocular lens (IOL) implantation can be an effective method for correcting corneal astigmatism in patients with vitreoretinal diseases and cataract. Our purpose is to report the outcome of toric IOL implantation in two cases - a patient with scleral-buckle-induced regular corneal astigmatism and a patient with keratoconus following pars plana vitrectomy. As far as we are aware, there are no reported cases of toric IOL implantation in a vitrectomized eye with keratoconus nor of toric IOL implantation in patients with scleral-buckle-induced regular corneal astigmatism. Two patients with myopia and high corneal astigmatism underwent cataract operation with toric IOL implantation after posterior segment surgery. Myopia and high astigmatism (>2.5 diopter) were caused by previous scleral buckling in one case and by keratoconus in the other case. Pre- and postoperative examinations during the follow-up of included uncorrected and spectacle corrected distance visual acuity (UCDVA/CDVA), automated kerato-refractometry (Topcon), Pentacam HR, IOL Master (Zeiss) axial length measurements and fundus optical coherence tomography (Zeiss). One year postoperatively, the UCDVA and CDVA were 20/25 and 20/20 in both cases, respectively. The absolute residual refractive astigmatism was 1.0 and 0.75 Diopters, respectively. The IOL rotation was within 3° in both eyes, therefore IOL repositioning was not necessary. Complications were not observed in our cases. These cases demonstrate that toric IOL implantation is a predictable and safe method for the correction of high corneal astigmatism in complicated cases with different origins. Irregular corneal astigmatism in keratoconus or scleral-buckle-induced regular astigmatisms can be equally well corrected with the use of toric IOL during cataract surgery. Previous scleral buckling or pars plana vitrectomy seem to have no impact on the success of the toric IOL implantation, even in keratoconus. IOL rotational stability and refractive predictability in patients with a previous vitreoretinal surgery can be as good as in uncomplicated cases.

  2. Measurement of Two-Plasmon-Decay Dependence on Plasma Density Scale Length

    NASA Astrophysics Data System (ADS)

    Haberberger, D.

    2013-10-01

    An accurate understanding of the plasma scale-length (Lq) conditions near quarter-critical density is important in quantifying the hot electrons generated by the two-plasmon-decay (TPD) instability in long-scale-length plasmas. A novel target platform was developed to vary the density scale length and an innovative diagnostic was implemented to measure the density profiles above 1021 cm-3 where TPD is expected to have the largest growth. A series of experiments was performed using the four UV (351-nm) beams on OMEGA EP that varied the Lq by changing the radius of curvature of the target while maintaining a constant Iq/Tq. The fraction of laser energy converted to hot electrons (fhot) was observed to increase rapidly from 0.005% to 1% by increasing the plasma scale length from 130 μm to 300 μm, corresponding to target diameters of 0.4 mm to 8 mm. A new diagnostic was developed based on refractometry using angular spectral filters to overcome the large phase accumulation in standard interferometric techniques. The angular filter refractometer measures the refraction angles of a 10-ps, 263-nm probe laser after propagating through the plasma. An angular spectral filter is used in the Fourier plane of the probe beam, where the refractive angles of the rays are mapped to space. The edges of the filter are present in the image plane and represent contours of constant refraction angle. These contours are used to infer the phase of the probe beam, which are used to calculate the plasma density profile. In long-scale-length plasmas, the diagnostic currently measures plasma densities from ~1019 cm-3 to ~2 × 1021 cm-3. This material is based upon work supported by the Department of Energy National Nuclear Security Administration under Award Number DE-NA0001944. In collaboration with D. H. Edgell, S. X. Hu, S. Ivancic, R. Boni, C. Dorrer, and D. H. Froula (Laboratory for Laser Energetics, U. of Rochester).

  3. Difference of refraction values between standard autorefractometry and Plusoptix.

    PubMed

    Bogdănici, Camelia Margareta; Săndulache, Codrina Maria; Vasiliu, Rodica; Obadă, Otilia

    2016-01-01

    Aim: Comparison between the objective refraction measurement results determined with Topcon KR-8900 standard autorefractometer and Plusoptix A09 photo-refractometer in children. Material and methods: A prospective transversal study was performed in the Department of Ophthalmology of "Sf. Spiridon" Hospital in Iași on 90 eyes of 45 pediatric patients, with a mean age of 8,82 ± 3,52 years, examined with noncycloplegic measurements provided by Plusoptix A09 and cycloplegic and noncycloplegic measurements provided by Topcon KR-8900 standard autorefractometer. The clinical parameters compared were the following: spherical equivalent (SE), spherical and cylindrical values, and cylinder axis. Astigmatism was recorded and evaluated with the cylindrical value on minus after transposition. The statistical calculation was performed with paired t-tests and Pearson's correlation analysis. All the data were analyzed with SPSS statistical package 19 (SPSS for Windows, Chicago, IL). Results: Plusoptix A09 noncycloplegic values were relatively equal between the eyes, with slightly lower values compared to noncycloplegic auto refractometry. Mean (± SD) measurements provided by Plusoptix AO9 were the following: spherical power 1.11 ± 1.52, cylindrical power 0.80 ± 0.80, and spherical equivalent 0.71 ± 1.39. The noncycloplegic auto refractometer mean (± SD) measurements were spherical power 1.12 ± 1.63, cylindrical power 0.79 ± 0,77 and spherical equivalent 0.71 ± 1.58. The cycloplegic auto refractometer mean (± SD) measurements were spherical power 2.08 ± 1.95, cylindrical power 0,82 ± 0.85 and spherical equivalent 1.68 ± 1.87. 32% of the eyes were hyperopic, 2.67% were myopic, 65.33% had astigmatism, and 30% eyes had amblyopia. Conclusions: Noncycloplegic objective refraction values were similar with those determined by autorefractometry. Plusoptix had an important role in the ophthalmological screening, but did not detect higher refractive errors, justifying the cycloplegic autorefractometry.

  4. Multi-color phase imaging and sickle cell anemia (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Hosseini, Poorya; Zhou, Renjie; Yaqoob, Zahid; So, Peter T. C.

    2016-03-01

    Quantitative phase measurements at multiple wavelengths has created an opportunity for exploring new avenues in phase microscopy such as enhancing imaging-depth (1), measuring hemoglobin concentrations in erythrocytes (2), and more recently in tomographic mapping of the refractive index of live cells (3). To this end, quantitative phase imaging has been demonstrated both at few selected spectral points as well as with high spectral resolution (4,5). However, most of these developed techniques compromise imaging speed, field of view, or the spectral resolution to perform interferometric measurements at multiple colors. In the specific application of quantitative phase in studying blood diseases and red blood cells, current techniques lack the required sensitivity to quantify biological properties of interest at individual cell level. Recently, we have set out to develop a stable quantitative interferometric microscope allowing for measurements of such properties for red cells without compromising field of view or speed of the measurements. The feasibility of the approach will be initially demonstrated in measuring dispersion curves of known solutions, followed by measuring biological properties of red cells in sickle cell anemia. References: 1. Mann CJ, Bingham PR, Paquit VC, Tobin KW. Quantitative phase imaging by three-wavelength digital holography. Opt Express. 2008;16(13):9753-64. 2. Park Y, Yamauchi T, Choi W, Dasari R, Feld MS. Spectroscopic phase microscopy for quantifying hemoglobin concentrations in intact red blood cells. Opt Lett. 2009;34(23):3668-70. 3. Hosseini P, Sung Y, Choi Y, Lue N, Yaqoob Z, So P. Scanning color optical tomography (SCOT). Opt Express. 2015;23(15):19752-62. 4. Jung J-H, Jang J, Park Y. Spectro-refractometry of individual microscopic objects using swept-source quantitative phase imaging. Anal Chem. 2013;85(21):10519-25. 5. Rinehart M, Zhu Y, Wax A. Quantitative phase spectroscopy. Biomed Opt Express. 2012;3(5):958-65.

  5. [Preliminary Investigation of the Amount, the Molecular Weight and the Activity of Polysaccharides from Chaenomeles Speciosa Fruits in Ethanol Fractional Precipitation].

    PubMed

    Tian, Bing-mei; Xie, Xiao-mei; Shen, Pan-pan; Yang, Mo; Zhang, Sheng-long; Tang, Qing-jiu

    2015-05-01

    Chaenomeles speciosa fruits were extracted using water. The extracts were precipitated with 20%~95% (φ) ethanol, respectively. The amount of total polysaccharide was measured with phenol-sulfuric acid method. A method using high-performance size-exclusion chromatography (HPSEC) equipped with multiangle laser-light-scattering photometry (MALLS) and differential refractometry (RI) was presented for determining the molecular weight and molecular weigh distribution. RAW264.7 macrophage were cultured and stimulated with the polysaccharides in vitro and the production of nitric oxide in the cells was determined by the Griess assay. The aim of the study is to determine the amount and the molecular weight of the polysaccharides from Chaenomeles speciosa fruits, and preliminary investigate the immunomodulatory activity, The study provided the basis datas for the further research of Chaenomeles speciosa fruits. , and provided a simple and system method for the research of natural polysaccharide. The ethanol fractional precipitation showed that the order of total polysaccharide content was 95%>80%>40% ≥60%>20%. The results indicated that most polysaccharide from Chaenomeles speciosa fruits might be precipitated when ethanol concentration was up to 95% (T) and the crude polysaccharide purity had risen from 35. 1% to 45. 0% when the concentration of ethanol increased from 20% to 95%. HPSEC-MALLS-RI system showed that all the polysaccharide samples had the similar compositions. They appeared three chromatographic peaks and the retention time were not apparently different. The Mw were 6. 570 X 10(4) g . mol-1 and 1. 393 X 10(4) g . mol-1 respectively, and one less than 10 000 which was failure to obtain accurate values. The molecular weight of the first two polysaccharide distribution index(Mw/Mn)were 1. 336 and 1. 639 respectively. The polysaccharide samples had not exhibited immunomodulatory activity assessed on the basis of nitric oxide production by RAW264. 7 macrophage cells in the experiment.

  6. Chemical vapor deposition of anisotropic ultrathin gold films on optical fibers: real-time sensing by tilted fiber Bragg gratings and use of a dielectric pre-coating

    NASA Astrophysics Data System (ADS)

    Mandia, David J.; Zhou, Wenjun; Ward, Matthew J.; Joress, Howie; Giorgi, Javier B.; Gordon, Peter; Albert, Jacques; Barry, Seán. T.

    2014-09-01

    Tilted fiber Bragg gratings (TFBGs) are refractometry-based sensor platforms that have been employed herein as devices for the real-time monitoring of chemical vapour deposition (CVD) in the near-infrared range (NIR). The coreguided light launched within the TFBG core is back-reflected off a gold mirror sputtered onto the fiber-end and is scattered out into the cladding where it can interact with a nucleating thin film. Evanescent fields of the growing gold nanostructures behave differently depending on the polarization state of the core-guided light interrogating the growing film, therefore the resulting spectral profile is typically decomposed into two separate peak families for the orthogonal S- and P-polarizations. Wavelength shifts and attenuation profiles generated from gold films in the thickness regime of 5-100 nm are typically degenerate for deposition directly onto the TFBG. However, a polarization-dependence can be imposed by adding a thin dielectric pre-coating onto the TFBG prior to using the device for CVD monitoring of the ultrathin gold films. It is found that addition of the pre-coating enhances the sensitivity of the P-polarized peak family to the deposition of ultrathin gold films and renders the films optically anisotropic. It is shown herein that addition of the metal oxide coating can increase the peak-to-peak wavelength separation between orthogonal polarization modes as well as allow for easy resonance tracking during deposition. This is also the first reporting of anisotropic gold films generated from this particular gold precursor and CVD process. Using an ensemble of x-ray techniques, the local fine structure of the gold films deposited directly on the TFBG is compared to gold films of similar thicknesses deposited on the Al2O3 pre-coated TFBG and witness slides.

  7. Use of analyte-modulated modal power distribution in multimode optical fibers for simultaneous single-wavelength evanescent-wave refractometry and spectrometry.

    PubMed

    Potyrailo, R A; Ruddy, V P; Hieftje, G M

    1999-11-01

    A new method is described for the simultaneous determination of absorbance and refractive index of a sample medium. The method is based on measurement of the analyte-modulated modal power distribution (MPD) in a multimode waveguide. In turn, the MPD is quantified by the far-field spatial pattern and intensity of light, i.e., the Fraunhofer diffraction pattern (registered on a CCD camera), that emerges from a multimode optical fiber. Operationally, light that is sent down the fiber interacts with the surrounding analyte-containing medium by means of the evanescent wave at the fiber boundary. The light flux in the propagating beam and the internal reflection angles within the fiber are both affected by optical absorption connected with the analyte and by the refractive index of the analyte-containing medium. In turn, these angles are reflected in the angular divergence of the beam as it leaves the fiber. As a result, the Fraunhofer diffraction pattern of that beam yields two parameters that can, together, be used to deduce refractive index and absorbance. This MPD based detection offers important advantages over traditional evanescent-wave detection strategies which rely on recording only the total transmitted optical power or its lost fraction. First, simultaneous determination of sample refractive index and absorbance is possible at a single probe wavelength. Second, the sensitivity of refractometric and absorption measurements can be controlled simply, either by adjusting the distance between the end face of the fiber and the CCD detector or by monitoring selected modal groups at the fiber output. As a demonstration of these capabilities, several weakly absorbing solutions were examined, with refractive indices in the range from 1.3330 to 1.4553 and with absorption coefficients in the range 0-16 cm-1. The new detection strategy is likely to be important in applications in which sample coloration varies and when it is necessary to compensate for variations in the refractive index of a sample.

  8. NASA Tech Briefs, May 2010

    NASA Technical Reports Server (NTRS)

    2010-01-01

    Topics covered include: Instrument for Analysis of Greenland's Glacier Mills Cryogenic Moisture Apparatus; A Transportable Gravity Gradiometer Based on Atom Interferometry; Three Methods of Detection of Hydrazines; Crossed, Small-Deflection Energy Analyzer for Wind/Temperature Spectrometer; Wavefront Correction for Large, Flexible Antenna Reflector; Novel Micro Strip-to-Waveguide Feed Employing a Double-Y Junction; Thin-Film Ferro Electric-Coupled Microstripline Phase Shifters With Reduced Device Hysteresis; Two-Stage, 90-GHz, Low-Noise Amplifier; A 311-GHz Fundamental Oscillator Using InP HBT Technology; FPGA Coprocessor Design for an Onboard Multi-Angle Spectro-Polarimetric Imager; Serrating Nozzle Surfaces for Complete Transfer of Droplets; Turbomolecular Pumps for Holding Gases in Open Containers; Triaxial Swirl Injector Element for Liquid-Fueled Engines; Integrated Budget Office Toolbox; PLOT3D Export Tool for Tecplot; Math Description Engine Software Development Kit; Astronaut Office Scheduling System Software; ISS Solar Array Management; Probabilistic Structural Analysis Program; SPOT Program; Integrated Hybrid System Architecture for Risk Analysis; System for Packaging Planetary Samples for Return to Earth; Offset Compound Gear Drive; Low-Dead-Volume Inlet for Vacuum Chamber; Simple Check Valves for Microfluidic Devices; A Capillary-Based Static Phase Separator for Highly Variable Wetting Conditions; Gimballing Spacecraft Thruster; Finned Carbon-Carbon Heat Pipe with Potassium Working Fluid; Lightweight Heat Pipes Made from Magnesium; Ceramic Rail-Race Ball Bearings; Improved OTEC System for a Submarine Robot; Reflector Surface Error Compensation in Dual-Reflector Antennas; Enriched Storable Oxidizers for Rocket Engines; Planar Submillimeter-Wave Mixer Technology with Integrated Antenna; Widely Tunable Mode-Hop-Free External-Cavity Quantum Cascade Laser; Non-Geiger-Mode Single-Photon Avalanche Detector with Low Excess Noise; Using Whispering-Gallery-Mode Resonators for Refractometry; RF Device for Acquiring Images of the Human Body; Reactive Collision Avoidance Algorithm; Fast Solution in Sparse LDA for Binary Classification; Modeling Common-Sense Decisions in Artificial Intelligence; Graph-Based Path-Planning for Titan Balloons; Nanolaminate Membranes as Cylindrical Telescope Reflectors; Air-Sea Spray Airborne Radar Profiler Characterizes Energy Fluxes in Hurricanes; Large Telescope Segmented Primary Mirror Alignment; and Simplified Night Sky Display System.

  9. Erosive and cariogenicity potential of pediatric drugs: study of physicochemical parameters.

    PubMed

    Xavier, Alidianne Fábia C; Moura, Eline F F; Azevedo, Waldeneide F; Vieira, Fernando F; Abreu, Mauro H N G; Cavalcanti, Alessandro L

    2013-12-10

    Pediatric medications may possess a high erosive potential to dental tissues due to the existence of acid components in their formulations. The purpose was to determine the erosive and cariogenic potential of pediatric oral liquid medications through the analysis of their physicochemical properties in vitro. A total of 59 substances were selected from the drug reference list of the National Health Surveillance Agency (ANVISA), which belong to 11 therapeutic classes, as follows: analgesics, non-steroidal anti-inflammatory, corticosteroids, antihistamines, antitussives, bronchodilators, antibacterials, antiparasitics, antiemetics, anticonvulsants and antipsychotics. Measurement of pH was performed by potentiometry, using a digital pH meter. For the Total Titratable Acidity (TTA) chemical assay, a 0.1 N NaOH standard solution was used, which was titrated until drug pH was neutralized. The Total Soluble Solids Contents (TSSC) quantification was carried out by refractometry using Brix scale and the analysis of Total Sugar Content was performed according to Fehling's method. In addition, it was analyzed the information contained in the drug inserts with regard to the presence of sucrose and type of acid and sweetener added to the formulations. All drug classes showed acidic pH, and the lowest mean was found for antipsychotics (2.61 ± 0.08). There was a large variation in the TTA (0.1% - 1.18%) and SST (10.44% - 57.08%) values. High total sugar contents were identified in the antitussives (53.25%) and anticonvulsants (51.75%). As described in the drug inserts, sucrose was added in 47.5% of the formulations, as well as citric acid (39.0%), sodium saccharin (36.4%) and sorbitol (34.8%). The drugs analyzed herein showed physicochemical characteristics indicative of a cariogenic and erosive potential on dental tissues. Competent bodies' strategies should be implemented in order to broaden the knowledge of health professionals, drug manufacturers and general consuming public about the risks from the consumption of medicines potentially harmful to dental tissues.

  10. Compensation for spectacle lenses involves changes in proteoglycan synthesis in both the sclera and choroid.

    PubMed

    Nickla, D L; Wildsoet, C; Wallman, J

    1997-04-01

    It has been demonstrated that chick eye growth compensates for defocus imposed by spectacle lenses: the eye elongates in response to hyperopic defocus imposed by negative lenses and slows its elongation in response to myopic defocus imposed by positive lenses. We ask whether the synthesis of scleral extracellular matrix, specifically glycosaminoglycans, changes in parallel with the changes in ocular elongation. In addition, there is a choroidal component to compensation for spectacle lenses; the choroid thickens in response to myopic defocus and thins in response to hyperopic defocus. We ask whether choroidal glycosaminoglycan synthesis changes in parallel with changes in choroidal thickness. Chicks wore either a +15 diopter (D) or -15 D spectacle lens over one eye, or they wore one lens of each power over each eye for 5 days. At the end of this period, we measured refractive errors and ocular dimensions by refractometry and A-scan ultrasonography, respectively. Pieces of the scleras and choroids from these eyes were put into culture and the synthesis of glycosaminoglycans was assessed by measuring the incorporation of radioactive inorganic sulfur. We here report that the compensatory modulation of the length of the eye involves changes in the synthesis of glycosaminoglycans in the sclera, with synthesis increasing in eyes wearing -15 D spectacles lenses and decreasing in eyes wearing +15 D lenses. In addition, changes in the synthesis of glycosaminoglycans in the choroid are correlated with changes in choroidal thickness: eyes wearing +15 D lenses develop thicker choroids and these choroids synthesize more glycosaminoglycans than choroids from eyes wearing -15 D lenses. Changes in scleral glycosaminoglycan synthesis accompany lens-induced changes in the length of the eye. Furthermore, changes in the thickness of the choroid are also associated with changes in the synthesis of glycosaminoglycans. These results are consistent with the regulation of the growth of the eye being bidirectional, and with the retina being able to sense the sign of defocus.

  11. Evaluation of the BOD POD and leg-to-leg bioelectrical impedance analysis for estimating percent body fat in National Collegiate Athletic Association Division III collegiate wrestlers.

    PubMed

    Dixon, Curt B; Deitrick, Ronald W; Pierce, Joseph R; Cutrufello, Paul T; Drapeau, Linda L

    2005-02-01

    The purpose of this study was to compare percent body fat (%BF) estimated by air displacement plethysmography (ADP) and leg-to-leg bioelectrical impedance analysis (LBIA) with hydrostatic weighing (HW) in a group (n = 25) of NCAA Division III collegiate wrestlers. Body composition was assessed during the preseason wrestling weight certification program (WCP) using the NCAA approved methods (HW, 3-site skinfold [SF], and ADP) and LBIA, which is currently an unaccepted method of assessment. A urine specific gravity less than 1.020, measured by refractometry, was required before all testing. Each subject had all of the assessments performed on the same day. LBIA measurements (Athletic mode) were determined using a Tanita body fat analyzer (model TBF-300A). Hydrostatic weighing, corrected for residual lung volume, was used as the criterion measurement. The %BF data (mean +/- SD) were LBIA (12.3 +/- 4.6), ADP (13.8 +/- 6.3), SF (14.2 +/- 5.3), and HW (14.5 +/- 6.0). %BF estimated by LBIA was significantly (p < 0.01) smaller than HW and SF. There were no significant differences in body density or %BF estimated by ADP, SF, and HW. All methods showed significant correlations (r = 0.80-0.96; p < 0.01) with HW. The standard errors of estimate (SEE) for %BF were 1.68, 1.87, and 3.60%; pure errors (PE) were 1.88, 1.94, and 4.16% (ADP, SF, and LBIA, respectively). Bland-Atman plots for %BF demonstrated no systematic bias for ADP, SF, and LBIA when compared with HW. These preliminary findings support the use of ADP and SF for estimating %BF during the NCAA WCP in Division III wrestlers. LBIA, which consistently underestimated %BF, is not supported by these data as a valid assessment method for this athletic group.

  12. Characterizing string-of-pearls colloidal silica by multidetector hydrodynamic chromatography and comparison to multidetector size-exclusion chromatography, off-line multiangle static light scattering, and transmission electron microscopy.

    PubMed

    Brewer, Amandaa K; Striegel, André M

    2011-04-15

    The string-of-pearls-type morphology is ubiquitous, manifesting itself variously in proteins, vesicles, bacteria, synthetic polymers, and biopolymers. Characterizing the size and shape of analytes with such morphology, however, presents a challenge, due chiefly to the ease with which the "strings" can be broken during chromatographic analysis or to the paucity of information obtained from the benchmark microscopy and off-line light scattering methods. Here, we address this challenge with multidetector hydrodynamic chromatography (HDC), which has the ability to determine, simultaneously, the size, shape, and compactness and their distributions of string-of-pearls samples. We present the quadruple-detector HDC analysis of colloidal string-of-pearls silica, employing static multiangle and quasielastic light scattering, differential viscometry, and differential refractometry as detection methods. The multidetector approach shows a sample that is broadly polydisperse in both molar mass and size, with strings ranging from two to five particles, but which also contains a high concentration of single, unattached "pearls". Synergistic combination of the various size parameters obtained from the multiplicity of detectors employed shows that the strings with higher degrees of polymerization have a shape similar to the theory-predicted shape of a Gaussian random coil chain of nonoverlapping beads, while the strings with lower degrees of polymerization have a prolate ellipsoidal shape. The HDC technique is contrasted experimentally with multidetector size-exclusion chromatography, where, even under extremely gentle conditions, the strings still degraded during analysis. Such degradation is shown to be absent in HDC, as evidenced by the fact that the molar mass and radius of gyration obtained by HDC with multiangle static light scattering detection (HDC/MALS) compare quite favorably to those determined by off-line MALS analysis under otherwise identical conditions. The multidetector HDC results were also comparable to those obtained by transmission electron microscopy (TEM). Unlike off-line MALS or TEM, however, multidetector HDC is able to provide complete particle analysis based on the molar mass, size, shape, and compactness and their distributions for the entire sample population in less than 20 min. © 2011 American Chemical Society

  13. Relative density of urine: methods and clinical significance.

    PubMed

    Pradella, M; Dorizzi, R M; Rigolin, F

    1988-01-01

    The physical properties and chemical composition of urine are highly variable and are determined in large measure by the quantity and the type of food consumed. The specific gravity is the ratio of the density to that of water, and it is dependent on the number and weight of solute particles and on the temperature of the sample. The weight of solute particles is constituted mainly of urea (73%), chloride (5.4%), sodium (5.1%), potassium (2.4%), phosphate (2.0%), uric acid (1.7%), and sulfate (1.3%). Nevertheless, urine osmolality depends only on the number of solute particles. The renal production of maximally concentrated urine and formation of dilute urine may be reduced to two basic elements: (1) generation and maintenance of a renal medullary solute concentration hypertonic to plasma and (2) a mechanism for osmotic equilibration between the inner medulla and the collecting duct fluid. The interaction of the renal medullary countercurrent system, circulating levels of antidiuretic hormone, and thirst regulates water metabolism. Renin, aldosterone, prostaglandins, and kinins also play a role. Clinical estimation of the concentrating and diluting capacity can be performed by relatively simple provocative tests. However, urinary specific gravity after taking no fluids for 12 h overnight should be 1.025 or more, so that the second urine in the morning is a useful sample for screening purposes. Many preservation procedures affect specific gravity measurements. The concentration of solids (or water) in urine can be measured by weighing, hydrometer, refractometry, surface tension, osmolality, a reagent strip, or oscillations of a capillary tube. These measurements are interrelated, not identical. Urinary density measurement is useful to assess the disorders of water balance and to discriminate between prerenal azotemia and acute tubular necrosis. The water balance regulates the serum sodium concentration, therefore disorders are revealed by hypo- and hypernatremia. The disturbances are due to renal and nonrenal diseases, mainly liver, cardiovascular, intestinal, endocrine, and iatrogenic. Fluid management is an important topic of intensive care medicine. Moreover, the usefulness of specific gravity measurement of urine lies in interpreting other findings of urinalysis, both chemical and microscopical.

  14. Benchmarking passive transfer of immunity and growth in dairy calves.

    PubMed

    Atkinson, D J; von Keyserlingk, M A G; Weary, D M

    2017-05-01

    Poor health and growth in young dairy calves can have lasting effects on their development and future production. This study benchmarked calf-rearing outcomes in a cohort of Canadian dairy farms, reported these findings back to producers and their veterinarians, and documented the results. A total of 18 Holstein dairy farms were recruited, all in British Columbia. Blood samples were collected from calves aged 1 to 7 d. We estimated serum total protein levels using digital refractometry, and failure of passive transfer (FPT) was defined as values below 5.2 g/dL. We estimated average daily gain (ADG) for preweaned heifers (1 to 70 d old) using heart-girth tape measurements, and analyzed early (≤35 d) and late (>35 d) growth separately. At first assessment, the average farm FPT rate was 16%. Overall, ADG was 0.68 kg/d, with early and late growth rates of 0.51 and 0.90 kg/d, respectively. Following delivery of the benchmark reports, all participants volunteered to undergo a second assessment. The majority (83%) made at least 1 change in their colostrum-management or milk-feeding practices, including increased colostrum at first feeding, reduced time to first colostrum, and increased initial and maximum daily milk allowances. The farms that made these changes experienced improved outcomes. On the 11 farms that made changes to improve colostrum feeding, the rate of FPT declined from 21 ± 10% before benchmarking to 11 ± 10% after making the changes. On the 10 farms that made changes to improve calf growth, ADG improved from 0.66 ± 0.09 kg/d before benchmarking to 0.72 ± 0.08 kg/d after making the management changes. Increases in ADG were greatest in the early milk-feeding period, averaging 0.13 kg/d higher than pre-benchmarking values for calves ≤35 d of age. Benchmarking specific outcomes associated with calf rearing can motivate producer engagement in calf care, leading to improved outcomes for calves on farms that apply relevant management changes. Copyright © 2017 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  15. Using Whispering-Gallery-Mode Resonators for Refractometry

    NASA Technical Reports Server (NTRS)

    Matsko, Andrey; Savchenkov, Anatoliy; Strekalov, Dmitry; Iltchenko, Vladimir; Maleki, Lute

    2010-01-01

    A method of determining the refractive and absorptive properties of optically transparent materials involves a combination of theoretical and experimental analysis of electromagnetic responses of whispering-gallery-mode (WGM) resonator disks made of those materials. The method was conceived especially for use in studying transparent photorefractive materials, for which purpose this method affords unprecedented levels of sensitivity and accuracy. The method is expected to be particularly useful for measuring temporally varying refractive and absorptive properties of photorefractive materials at infrared wavelengths. Still more particularly, the method is expected to be useful for measuring drifts in these properties that are so slow that, heretofore, the properties were assumed to be constant. The basic idea of the method is to attempt to infer values of the photorefractive properties of a material by seeking to match (1) theoretical predictions of the spectral responses (or selected features thereof) of a WGM of known dimensions made of the material with (2) the actual spectral responses (or selected features thereof). Spectral features that are useful for this purpose include resonance frequencies, free spectral ranges (differences between resonance frequencies of adjacently numbered modes), and resonance quality factors (Q values). The method has been demonstrated in several experiments, one of which was performed on a WGM resonator made from a disk of LiNbO3 doped with 5 percent of MgO. The free spectral range of the resonator was approximately equal to 3.42 GHz at wavelengths in the vicinity of 780 nm, the smallest full width at half maximum of a mode was approximately equal to 50 MHz, and the thickness of the resonator in the area of mode localization was 30 microns. In the experiment, laser power of 9 mW was coupled into the resonator with an efficiency of 75 percent, and the laser was scanned over a frequency band 9 GHz wide at a nominal wavelength of approximately equal to 780 nm. Resonance frequencies were measured as functions of time during several hours of exposure to the laser light. The results of these measurements, plotted in the figure, show a pronounced collective frequency drift of the resonator modes. The size of the drift has been estimated to correspond to a change of 8.5 x 10(exp -5) in the effective ordinary index of refraction of the resonator material.

  16. Visual impairment and spectacle use in schoolchildren in rural and urban regions in Beijing.

    PubMed

    Guo, Yin; Liu, Li Juan; Xu, Liang; Lv, Yan Yun; Tang, Ping; Feng, Yi; Meng, Lei; Jonas, Jost B

    2014-01-01

    To determine prevalence and associations of visual impairment and frequency of spectacle use among grade 1 and grade 4 students in Beijing. This school-based, cross-sectional study included 382 grade 1 children (age 6.3 ± 0.5 years) and 299 grade 4 children (age 9.4 ± 0.7 years) who underwent a comprehensive eye examination including visual acuity, noncycloplegic refractometry, and ocular biometry. Presenting visual acuity (mean 0.04 ± 0.17 logMAR) was associated with younger age (p = 0.002), hyperopic refractive error (p<0.001), and male sex (p = 0.03). Presenting visual impairment (presenting visual acuity ≤20/40 in the better eye) was found in 44 children (prevalence 6.64 ± 1.0% [95% confidence interval (CI) 4.74, 8.54]). Mean best-corrected visual acuity (right eyes -0.02 ± 0.04 logMAR) was associated with more hyperopic refractive error (p = 0.03) and rural region of habitation (p<0.001). The prevalence of best-corrected visual impairment (best-corrected visual acuity ≤20/40 in the better eye) was 2/652 (0.30 ± 0.21% [95% CI 0.00, 0.72]). Undercorrection of refractive error was present in 53 children (7.99 ± 1.05%) and was associated with older age (p = 0.003; B 0.53; OR 1.71 [95% CI 1.20, 2.42]), myopic refractive error (p = 0.001; B -0.72; OR 0.49 [95% CI 0.35, 0.68]), and longer axial length (p = 0.002; B 0.74; OR 2.10 [95% CI 1.32, 3.32]). Spectacle use was reported for 54 children (8.14 ± 1.06%). Mean refractive error of the worse eyes of these children was -2.09 ± 2.88 D (range -7.38 to +7.25 D). Factors associated with presenting visual impairment were older age, myopic refractive error, and higher maternal education level. Despite a prevalence of myopia of 33% in young schoolchildren in Greater Beijing, prevalence of best-corrected visual impairment (0.30% ± 0.21%), presenting visual impairment (6.64% ± 1.0%), and undercorrection of refractive error (7.99% ± 1.05%) were relatively low.

  17. Hematology and plasma chemistry reference intervals for cultured shortnose sturgeon (Acipenser brevirostrum).

    PubMed

    Knowles, Susan; Hrubec, Terry C; Smith, Stephen A; Bakal, Robert S

    2006-12-01

    The shortnose sturgeon, Acipenser brevirostrum, is an imperiled species distributed along the Atlantic coast of North America. Interest in replenishing wild stocks with hatchery-reared fish has created a need for accurate hematologic and biochemical reference intervals to evaluate the health of both fish raised in aquaculture systems and fish in the wild. The objective of this study was to generate hematologic and biochemistry reference intervals for healthy shortnose sturgeon. Blood samples were collected in heparinized tubes from 77 shortnose sturgeon raised in flow-through aquaculture systems. Whole blood and plasma samples were analyzed for hematologic and biochemical variables using standard techniques. Reference intervals were calculated as the central 95% (percentile) of data. Hematologic reference intervals (n = 46) were as follows: PCV 26-46%, hemoglobin 5.7-8.7 g/dL, MCV 307-520 fL, MCH 65.9-107.1 pg, MCHC 15-30 g/dL, plasma proteins (refractometry) 2.8-6.0 g/dL, RBC count 0.65-1.09 x 10(6)/microL, total WBC count 28,376-90,789/microL, small lymphocytes 9063-56,656/microL, large lymphocytes 2122-10,435/microL, neutrophils 3758-33,592/microL, monocytes 0-7137/microL, eosinophils 0-1544/microL, thrombocyte-like cells 6863-23,046/microL, thrombocytes 32,205-122,179/microL, and neutrophil:lymphocyte ratio 0.068-1.026. Plasma chemistry reference intervals (n = 77) were as follows: total protein 2.7-5.3 g/dL, albumin 0.8-1.7 g/dL, globulins 1.8-3.7 mg/dL, creatinine 0-1.4 mg/dL, total bilirubin 0-0.1 mg/dL, alkaline phosphatase 47-497 U/L, aspartate aminotransferase 90-311 U/L, sodium 124-141 mmol/L, potassium 2.9-3.7 mmol/L, chloride 106-121 mmol/L, calcium 6.6-12.1 mg/dL, magnesium 1.6-2.3 mg/dL, phosphorus 5.1-8.1 mg/dL, glucose 37-74 mg/dL, cholesterol 42-133 mg/dL, and osmolality 232-289 mOsm/kg. Reference values reported here will be useful for the early detection, identification, and monitoring of disease and sublethal conditions in cultured shortnose sturgeon.

  18. Chemical-assisted femtosecond laser writing of lab-in-fibers.

    PubMed

    Haque, Moez; Lee, Kenneth K C; Ho, Stephen; Fernandes, Luís A; Herman, Peter R

    2014-10-07

    The lab-on-chip (LOC) platform has presented a powerful opportunity to improve functionalization, parallelization, and miniaturization on planar or multilevel geometries that has not been possible with fiber optic technology. A migration of such LOC devices into the optical fiber platform would therefore open the revolutionary prospect of creating novel lab-in-fiber (LIF) systems on the basis of an efficient optical transport highway for multifunctional sensing. For the LIF, the core optical waveguide inherently offers a facile means to interconnect numerous types of sensing elements along the optical fiber, presenting a radical opportunity for optimizing the packaging and densification of diverse components in convenient geometries beyond that available with conventional LOCs. In this paper, three-dimensional patterning inside the optical fiber by femtosecond laser writing, together with selective chemical etching, is presented as a powerful tool to form refractive index structures such as optical waveguides and gratings as well as to open buried microfluidic channels and optical resonators inside the flexible and robust glass fiber. In this approach, optically smooth surfaces (~12 nm rms) are introduced for the first time inside the fiber cladding that precisely conform to planar nanograting structures when formed by aberration-free focusing with an oil-immersion lens across the cylindrical fiber wall. This process has enabled optofluidic components to be precisely embedded within the fiber to be probed by either the single-mode fiber core waveguide or the laser-formed optical circuits. We establish cladding waveguides, X-couplers, fiber Bragg gratings, microholes, mirrors, optofluidic resonators, and microfluidic reservoirs that define the building blocks for facile interconnection of inline core-waveguide devices with cladding optofluidics. With these components, more advanced, integrated, and multiplexed fiber microsystems are presented demonstrating fluorescence detection, Fabry-Perot interferometric refractometry, and simultaneous sensing of refractive index, temperature, and bending strain. The flexible writing technique and multiplexed sensors described here open powerful prospects to migrate the benefits of LOCs into a more flexible and miniature LIF platform for highly functional and distributed sensing capabilities. The waveguide backbone of the LIF inherently provides an efficient exchange of information, combining sensing data that are attractive in telecom networks, smart catheters for medical procedures, compact sensors for security and defense, shape sensors, and low-cost health care products.

  19. Evaluation of the Brix refractometer to estimate immunoglobulin G concentration in bovine colostrum.

    PubMed

    Quigley, J D; Lago, A; Chapman, C; Erickson, P; Polo, J

    2013-02-01

    Refractometry using a Brix refractometer has been proposed as a means to estimate IgG concentration in bovine maternal colostrum (MC). The refractometer has advantages over other methods of estimating IgG concentration in that the Brix refractometer is inexpensive, readily available, less fragile, and less sensitive to variation in colostral temperature, season of the year and other factors. Samples of first-milking MC were collected from 7 dairy farms in Maine, New Hampshire, Vermont, and Connecticut (n=84) and 1 dairy farm in California (n=99). The MC was milked from the cow at 6.1 ± 5.6h postparturition and a sample was evaluated for Brix percentage by using an optical refractometer. Two additional samples (30 mL) were collected from the milk bucket, placed in vials, and frozen before analysis of total IgG by radial immunodiffusion (RID) using commercially available plates and by turbidimetric immunoassay (TIA). The second sample was analyzed for total bacterial counts and coliform counts at laboratories in New York (Northeast samples) and California (California samples). The Brix percentage (mean ± SD) was 23.8 ± 3.5, IgG concentration measured by RID was 73.4 ± 26.2g/L, and IgG concentration measured by TIA was 67.5 ± 25.0 g/L. The Brix percentage was highly correlated (r=0.75) with IgG analyzed by RID. The Brix percentage cut point to define high- or low-quality colostrum (50 g of IgG/L measured by RID) that classified more samples correctly given the proportion of high- (86%) and low-quality (14%) samples in this study was 21%, which is slightly lower than other recent estimates of Brix measurements. At this cut point, the test sensitivity, specificity, positive and negative predictive values, and accuracy were 92.9, 65.5, 93.5, 63.3, and 88.5%, respectively. Measurement of IgG by TIA correlated with Brix (r=0.63) and RID (r=0.87); however, TIA and RID methods of IgG measurement were not consistent throughout the range of samples tested. We conclude that Brix measurement of total solids in fresh MC is an inexpensive, rapid, and satisfactorily accurate method of estimating IgG concentration. A cut point of 21% Brix to estimate samples of MC >50 g/L was most appropriate for our data. Measurement of IgG in MC by TIA differed from measurement by RID. Copyright © 2013 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  20. Prevalence and Associated Factors of Myopia in High-School Students in Beijing

    PubMed Central

    Duan, Jia Li; Luo, Yan Xia; Liu, Li Juan; Li, Xia; Gao, Qi; Zhu, Hui Ping; He, Yan; Xu, Liang; Jonas, Jost B; Wang, Wei; Guo, Xiu Hua

    2015-01-01

    Purpose To evaluate prevalence and associated factors for myopia in high school students in Beijing. Methods Grade 10 and 11 high school students were randomly selected from nine randomly selected districts of Beijing. The students underwent non-cylcoplegic auto-refractometry and an interview. Results Out of 4798 eligible students, 4677 (93.4%) students (mean age:16.9±0.7years;range:16–18 years) participated. Mean refractive error of right eyes and left eyes was −2.78±2.29 diopters and −2.59±2.50 diopters, respectively. Prevalence of myopia (defined as ≤ −1.00 diopters in the worse eye) was 80.7% (95% Confidence Interval (CI): 79.6–81.8%). Out of 3773 students with myopia, 1525 (40.4%) wore glasses daily. In multiple logistic regression analysis, a higher prevalence of myopia was associated with female sex (odds ratio (OR) = 1.31;95%CI:1.11–1.55), Han ethnicity (OR = 1.64;95%CI:1.28–2.11), attending key schools (OR = 1.48;95%CI:1.24,1.77), higher family income (OR = 1.37;95%CI:1.09–1.71), longer time spent for near work (OR = 1.43;95%CI:1.06–1.93), shorter near work distance (OR = 1.87;95%CI:1.55–2.26), lower frequency of active rest during studying (OR = 1.40;95%CI:1.16–1.70), and parental myopia (OR = 2.28;95%CI:1.80–2.87). The interaction between distance from near work and time spent for near work was statistically (P = 0.03) significant. In multiple logistic regression analysis, higher prevalence of high myopia (≤-6.0 diopters) was associated with studying in key schools (OR = 1.38;95%CI:1.05,1.81), lower frequency of active rest during studying (OR = 1.40;95%CI:1.09,1.79), and a higher number of myopic parents (OR = 2.66;95%CI:2.08,3.40). Conclusions A prevalence of about 80% for myopia and a prevalence of about 10% for high myopia in students aged 16 to 18 years and attending classes of grade 10 and 11 in a Chinese metropolitan region is another example of the high prevalence of moderate and high myopia in metropolitan areas of China. With this young myopic generation getting older, myopia as cause for visual impairment and blindness may further increase in importance. Future studies may address whether active rests during studying with looking into the distance are preventive against myopia development or progression. PMID:25803875

  1. Outdoor activity and myopia among primary students in rural and urban regions of Beijing.

    PubMed

    Guo, Yin; Liu, Li Juan; Xu, Liang; Lv, Yan Yun; Tang, Ping; Feng, Yi; Meng, Meng; Jonas, Jost B

    2013-02-01

    To assess associations among outdoor activity, ocular biometric parameters, and myopia among grade 1 and grade 4 primary students in Beijing. School-based, cross-sectional study. A total of 382 grade 1 and 299 grade 4 children participated in the study. The children underwent a comprehensive eye examination, including ocular biometry by optical low-coherence reflectometry and noncycloplegic refractometry. Parents and children participated in a detailed interview, including questions on time spent indoors and outdoors. Factors associated with myopia. The study included 681 children, with 382 (56.1%) students from grade 1 (mean age, 6.3 ± 0.5 years; range, 5-8 years) and 299 students from grade 4 (mean age, 9.4 ± 0.7 years; range, 8-13 years); 370 students (54.3%) lived in the urban region. The mean daily time spent outdoors was 1.6 ± 0.8 hours (range, 0.5-5.1 hours). In multivariate analysis, axial length was significantly associated with older age (P<0.001; standardized β coefficient, 0.28), taller body height (P = 0.001; β, 0.18), maternal myopia (P = 0.03; β, 0.09), and urban region of habitation (P<0.001; β, -0.21), or alternatively to the region of habitation, with less time spent outdoors (P = 0.001; β, -0.16) and more time spent indoors studying (P = 0.02; β, 0.10). The axial length-to-corneal curvature radius ratio was associated with older age, urban region of habitation, maternal and paternal myopia, and paternal level of education. Presence of myopia (defined as refractive error ≤-1 diopters in the right eye) was associated with older age (P<0.001; odds ratio [OR], 1.45; 95% confidence interval [CI], 1.24-1.69), maternal myopia (P<0.001; OR, 2.99; 95% CI, 1.94-5.35), and urban region of habitation (P<0.001; OR, 0.17; 95% CI, 0.11-0.26), or alternatively to the region of habitation, with less time spent outdoors (P<0.001; OR, 0.32; 95% CI, 0.21-0.48) and more time spent indoors studying (P<0.001; OR, 1.38; 95% CI, 1.09-1.75). Less outdoor activity, more indoor studying, older age, maternal myopia, and urban region of habitation were associated with longer ocular axial length and myopia in grade 1 and grade 4 primary school children in Greater Beijing. Remaining outdoors more (e.g., during school) may reduce the high prevalence of myopia in the young generation in Beijing. Copyright © 2013 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  2. Kinetics of phase transition in protein solutions on microscopic and mesoscopic length scales

    NASA Astrophysics Data System (ADS)

    Filobelo, Luis F.

    2005-11-01

    Phase transformations in solutions of macromolecules are fundamental for all living things, and of great importance in science and industry. For instance, insulin is biosynthesized in the beta cells of the pancreas and stored in crystalline form, which protects it form cleavage, until it is needed. Certain diseases such as Alzheimer, sickle cell anemia, and eye cataract are produced by the polymerization of protein molecules, which loose their functionality after the phase transition. Additionally, separation operations in manufacturing of pharmaceuticals can be eliminated if the crystals produced have a narrow size distribution. The nucleation and growth of crystals can be adequately controlled only if the mechanisms that govern these processes are well understood. Here we have investigated several facets of the kinetics controlling the behavior of phase transition in protein solutions. We performed experiments to determine the homogenous nucleation rate for lysozyme and insulin crystals and the contribution of heterogeneously nucleated crystals. In the first segment of this work we discuss the existence of a solution-to-crystal spinodal boundary derived from these determinations, and showed that the formation of crystalline nuclei from solution occur in two steps for lysozyme: the formation of quasi-droplets of a disordered intermediate, followed by the nucleation of ordered crystalline embryos within these droplets in which the rate of each step depends on a respective free energy barrier and on the growth rate of its near-critical clusters. We addressed experimentally the relative significance of the free-energy barriers and the kinetic factors for the nucleation of crystals from solution. Using dynamic and static light scattering along with differential refractometry, we also characterized the appearance of dense liquid droplets and the magnitude of the second osmotic virial coefficient B2 for insulin in both aqueous solution and in solution containing 15% (v/v) acetone and found that B2 was consistently lower for the acetone-containing insulin solutions, indicating stronger net attraction between insulin molecules. Since both conditions are inductive of crystallization, we conclude that the higher values of B 2 in acetone-free solutions reflect the presence of a repulsive maximum at intermediate separations in the intermolecular interaction potential, likely due to water structuring around the insulin molecules. We also found that the classic nucleation theory, in which fluctuations along one order parameters such as density are required for the phase transition to occur, applies to insulin. After establishing the rate-limiting role of kinetics in phase transitions, we characterized the temperature dependence of viscosity of protein solution in a wide range of concentrations. We found timescales dependence for lysozyme, suggesting that the probing beads move about local regions in short times, and through loosely bound networks in between local regions during longer times. We fitted our results to the Free Volume Theory and found that it does not apply at low protein concentrations. Finally, we found that hemoglobin undergoes aggregation in solution, which yields increased nucleation rates as the protein ages.

  3. High myopia in Greater Beijing School Children in 2016.

    PubMed

    Guo, Yin; Duan, Jia Li; Liu, Li Juan; Sun, Ying; Tang, Ping; Lv, Yan Yun; Xu, Liang; Jonas, Jost B

    2017-01-01

    To assess prevalence and associated factors of myopia and high myopia in schoolchildren in Greater Beijing. The school-based, cross-sectional Greater Beijing School Children Myopia study was carried out in the year 2016 in 54 schools randomly selected from 15 districts in Beijing. Non-cycloplegic auto-refractometry of the right eyes was performed. The study included 35,745 (99.4%) out of 35,968 eligible pupils with a mean age of 12.6±3.4 years (range 6-18 years). Prevalence of myopia defined as myopic refractive error of ≥-0.50 diopters (D),≥-1D,≥-6D,≥-8D and ≥-10D was 70.9%(95% confidence intervals (CI):70.5,71.4), 60.9% (95%CI:60.4,61.4), 8.6%(95%CI:8.4,8.9), 2.2%(95%CI:2.0,2.4), and 0.3% (95%CI:0.3,0.4), respectively. The frequency of high myopia (≥-6D, ≥-8D, ≥-10D) increased from 1.5% (95%CI:1.0,2.0), 0.4% (95%CI:0.1,0.6) and 0.1% (95%CI:0.00,0.02), respectively in 10-year-olds to 19.4% (95%CI:17.3,21.6), 5.2% (95%CI:4.0,6.4) and 0.9% (95%CI:0.4,1.5), respectively, in 18-year-olds. Mean refractive error in the 18-year-olds was -3.74±2.56D (median:-3.63D;range:-19.6D to + 6.25D). Higher prevalence of high myopia (≥-6D and ≥-8D) was correlated (all P<0.001) with older age (OR:1.18, and 1.15, respectively), female gender (OR: 1.44 and 1.40, respectively), higher body mass index (OR: 1.02 and 1.03, respectively), taller body height (OR: 1.03 and 1.02, respectively), urban region of habitation (OR: 1.26 and 1.33, respectively) and higher school type (OR:1.57 and 2.22, respectively). Prevalence of severe high myopia (≥-10D) was associated only with older age (P<0.001; OR: 1.44; 95%CI: 1.31, 1.59) but not with any education-related parameter such as higher school type (P = 0.48), urban region of habitation (P = 0.07) or female gender (P = 0.37). In this most recent survey, prevalence of high myopia (≥-6D:19.4%;≥-8D:5.2%;≥-10D:0.9%) in 18-year-old school children was higher than in previous surveys from mainland China. In contrast to minor high myopia and moderate high myopia (defined as myopic refractive error of <-10D), severe high myopia (myopic refractive error ≥-10D) was not strongly correlated with educational parameters.

  4. Validating a refractometer to evaluate immunoglobulin G concentration in Jersey colostrum and the effect of multiple freeze-thaw cycles on evaluating colostrum quality.

    PubMed

    Morrill, K M; Robertson, K E; Spring, M M; Robinson, A L; Tyler, H D

    2015-01-01

    The objectives of this study were to (1) validate a method using refractometry to rapidly and accurately determine immunoglobulin (IgG) concentration in Jersey colostrum, (2) determine whether there should be different refractive index (nD) and %Brix cut points for Jersey colostrum, and (3) evaluate the effect of multiple freeze-thaw (FT) cycles on radial immunodiffusion (RID) and a digital refractometer to determine IgG concentration in Jersey colostrum. Samples (n=58; 3L) of colostrum were collected from a dairy in northwestern Iowa. Samples were analyzed within 2h of collection for IgG concentration by RID, %Brix, and nD by refractometer and an estimate of IgG by colostrometer. Samples were frozen, placed on dry ice, and transported to the laboratory at Iowa State University (Ames). Samples arrived frozen and were placed in a -20°C manual-defrost freezer until further analysis. On d 7 (1FT), d 14 (2FT), and 1yr (3FT) all samples were thawed, analyzed for IgG by RID, %Brix, nD by refractometer, and IgG estimate by colostrometer, and frozen until reanalysis at the next time point. Fresh colostrum had a mean (±SD) IgG concentration of 72.91 (±33.53) mg/mL, 21.24% (±4.43) Brix, and nD 1.3669 (±0.0074). Multiple FT cycles did affect IgG as determined by RID and colostrometer reading. The IgG concentrations were greater in fresh and 1FT samples as compared with 2FT and 3FT samples (72.91, 75.38, 67.20, and 67.31mg of IgG/mL, respectively). The colostrometer reading was lower in 1FT samples compared with fresh and 2FT samples. Multiple FT cycles had no effect on nD or %Brix reading. In fresh samples, IgG concentration was moderately correlated with nD (r=0.79), %Brix (r=0.79), and colostrometer reading (r=0.79). Diagnostic test characteristics using the recommended cut point of 1.35966 nD resulted in similar sensitivities for 1FT and 2 FT samples (94.87 and 94.74%, respectively). Cut points of 18 and 19% Brix resulted in the greatest sensitivities (92.31 and 84.62%) and specificity (94.74 and 94.74%, respectively). The 18% Brix cut point resulted in 94.83% of the samples being correctly classified based on IgG concentration. These data support the use of digital refractometer to accurately and rapidly determine IgG concentration in fresh Jersey colostrum. Additionally, these data suggest that IgG concentration determined by RID is affected by multiple FT cycles, whereas estimates obtained by refractometer are not affected by multiple FT cycles. Copyright © 2015 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  5. Refractive Error, Visual Acuity and Causes of Vision Loss in Children in Shandong, China. The Shandong Children Eye Study

    PubMed Central

    Wu, Jian Feng; Bi, Hong Sheng; Wang, Shu Mei; Hu, Yuan Yuan; Wu, Hui; Sun, Wei; Lu, Tai Liang; Wang, Xing Rong; Jonas, Jost B.

    2013-01-01

    Purpose To examine the prevalence of refractive errors and prevalence and causes of vision loss among preschool and school children in East China. Methods Using a random cluster sampling in a cross-sectional school-based study design, children with an age of 4–18 years were selected from kindergartens, primary schools, and junior and senior high schools in the rural Guanxian County and the city of Weihai. All children underwent a complete ocular examination including measurement of uncorrected (UCVA) and best corrected visual acuity (BCVA) and auto-refractometry under cycloplegia. Myopia was defined as refractive error of ≤−0.5 diopters (D), high myopia as ≤−6.0D, and amblyopia as BCVA ≤20/32 without any obvious reason for vision reduction and with strabismus or refractive errors as potential reasons. Results Out of 6364 eligible children, 6026 (94.7%) children participated. Prevalence of myopia (overall: 36.9±0.6%;95% confidence interval (CI):36.0,38.0) increased (P<0.001) from 1.7±1.2% (95%CI:0.0,4.0) in the 4-years olds to 84.6±3.2% (95%CI:78.0,91.0) in 17-years olds. Myopia was associated with older age (OR:1.56;95%CI:1.52,1.60;P<0.001), female gender (OR:1.22;95%CI:1.08,1.39;P = 0.002) and urban region (OR:2.88;95%CI:2.53,3.29;P<0.001). Prevalence of high myopia (2.0±0.2%) increased from 0.7±0.3% (95%CI:0.1,1.3) in 10-years olds to 13.9±3.0 (95%CI:7.8,19.9) in 17-years olds. It was associated with older age (OR:1.50;95%CI:1.41,1.60;P<0.001) and urban region (OR:3.11;95%CI:2.08,4.66);P<0.001). Astigmatism (≥0.75D) (36.3±0.6%;95%CI:35.0,38.0) was associated with older age (P<0.001;OR:1.06;95%CI:1.04,1.09), more myopic refractive error (P<0.001;OR:0.94;95%CI:0.91,0.97) and urban region (P<0.001;OR:1.47;95%CI:1.31,1.64). BCVA was ≤20/40 in the better eye in 19 (0.32%) children. UCVA ≤20/40 in at least one eye was found in 2046 (34.05%) children, with undercorrected refractive error as cause in 1975 (32.9%) children. Amblyopia (BCVA ≤20/32) was detected in 44 (0.7%) children (11 children with bilateral amblyopia). Conclusions In coastal East China, about 14% of the 17-years olds were highly myopic, and 80% were myopic. Prevalence of myopia increased with older age, female gender and urban region. About 0.7% of pre-school children and school children were amblyopic. PMID:24376575

  6. EDITORIAL: The 19th International Conference on Optical Fibre Sensors, OFS-19 The 19th International Conference on Optical Fibre Sensors, OFS-19

    NASA Astrophysics Data System (ADS)

    Sampson, David D.; Jones, Julian D. C.; Tatam, Ralph P.

    2009-03-01

    OFS-19 was held in April 2008 in Perth, Australia, with Professor David Sampson (University of Western Australia) as General Chair assisted by Technical Programme Co-Chairs Professor Stephen Collins (Victoria University, Australia), Professor Kyunghwan Oh (Yonsei University, Korea) and Dr Ryozo Yamauchi (Fujikura Ltd, Japan). 'OFS-19' has once again affirmed the OFS series as the leading international conference for the optical fibre sensor community. Since its inception, in London in 1983, and under the leadership of an international steering committee independent of any learned society or professional institution, it has been held approximately every eighteen months. The venue nominally rotates from Europe, to the Americas, and thence to Asia and the Pacific. OFS-19 demonstrated the continuing vigour of the community, with some 240 papers presented, plus 8 tutorials; submissions and attendance were from 29 countries, with a little over half coming from the Asia-Pacific Region. In recent years, it has become a tradition to publish a post-conference special issue in Measurement Science and Technology, and these special issues offer a representative sample of the current status of the field. In the 25 years since OFS began, many of the early ideas and laboratory-based proof-of-principle experiments have successfully evolved into highly developed instrumentation systems and commercial products. One of the greatest success stories has been the optical fibre Bragg grating. Its exquisite intrinsic sensitivity to temperature and strain has led to an expanding niche in structural monitoring, especially in civil engineering. It has formed the 'beach-head' for penetration of optical fibre sensors into the oil and gas industry, initially in the harsh environment of down-hole monitoring. Latterly, it has paved the way for new applications of one of the earliest fibre optic sensors, the fibre hydrophone, which is now making its mark in sub-sea seismic surveying. Additionally, distributed fibre sensors, based on Raman or Brillouin scattering, are beginning to be deployed for remote and sub-sea infrastructure monitoring. Western Australia enjoys a booming oil and gas sector, and so OFS-19's Special Session entitled Oil & Gas: Current Practice-Future Opportunity was timely and locally relevant. An innovation at OFS-19 was turning the traditional first day's Workshop into a Tutorial Workshop delivered under the title Optical Fibre Sensors: Enabling the Next Generation, Stretching the Present Generation. International experts delivered a set of eight tutorials, covering both fundamentals and cutting-edge advances, to a large proportion of the conference delegates (the tutorials are available for download at obel.ee.uwa.edu.au/OFS-19). This special issue amply demonstrates in microcosm the breadth of the field of optical fibre sensors, with papers concerning applications in the oil and gas industry, in water and air quality, in civil engineering, as well as new sensors, sensor systems and methods for sensing. In addition, there are papers concerning sensor fabrication and calibration, as well as components of sensing systems. Several papers and topics are worthy of mention. The engineering of nanostructured materials promises much in many fields, including sensing in general. Thus, it is not surprising to find that nanotechnology is in evidence in the field of fibre sensing (Jarzebinska, Viegas). Microengineered mechanical structures also promise much for sensing and the exquisite 'head-of-a-pin' engineering of a cantilever on a fibre end-face is an elegant and versatile platform demonstrated here for refractometry (Alberts). The field has always provided fertile ground for new ideas, and this issue proves no exception. For example, three papers deal with new ways of solving the well-known issue of decoupling temperature from strain in fibre Bragg gratings (Guo, Nguyen, Yam). The ultimate endpoint for research in such a practical field is a useful deployed sensing system, and the oil and gas industry is the focus for four papers in this issue (Aref, Jackson, Mignani, Possetti). We hope that this special issue helps to further developments in the field of optical fibre sensors and would like to thank all the contributing authors and reviewers for making it possible. We also thank the staff at IOP Publishing for their support and in ensuring timely publication. OFS-20 will be held in Edinburgh, Scotland, 5--9 October 2009 (www.ofs20.org), with a corresponding special issue planned.

  7. EDITORIAL: Plasmas and plasmons: links in nanosilver Plasmas and plasmons: links in nanosilver

    NASA Astrophysics Data System (ADS)

    Demming, Anna

    2013-03-01

    Silver has long been valued not just for its rarity but also for its broad ranging attractive properties as a conductor, catalyst and antimicrobial agent, among others. In nanoscale structures, silver takes on a number of additional attributes, as properties such as antimicrobial activity show size dependence. In addition plasmonic properties are exhibited, which enhance local electromagnetic fields and can be hugely beneficial in sensing and imaging applications. As a result silver nanoparticles are increasingly in demand. In this issue researchers describe a microplasma-assisted electrochemical synthesis that allows excellent control over the size and spacing of the resulting particles, which are important parameters for optimizing their performance in device applications [1]. Wet chemistry [2] and lithography [3] are common processes for silver nanoparticle synthesis. However, other methods are constantly in development. Biosynthesis approaches have been attracting increasing interest as more environmentally friendly alternatives. Takayuki Kuwabara and colleagues at Xiamen University in China used the sundried biomass of Cinnamomum camphora leaf to reduce silver nitrate [4], demonstrating a cost-efficient alternative to conventional methods which might also be suitable for large-scale production. At Zhejiang Normal University researchers noted that the abasic site (AP site) in the DNA duplex can act as a capping scaffold in the generation of fluorescent silver nanoclusters [5]. In addition the resulting fluorescence of the nanocrystals can be used for detecting DNA single-nucleotide polymorphism. Researchers in Malaysia have also noted the potential sensing applications of nanoparticles of another noble metal for swine DNA [6]. They observed that single-strand DNA was absorbed on gold nanoparticles and led to a colour shift from pinkish-red to grey-purple. The shift was the result of a reduction in the surface plasmon resonance peak at 530 nm and new features appearing in the 620-800 nm regions of the absorption spectra. A number of research groups have investigated the possibility of exploiting the plasmonic properties of silver and gold nanostructures for optoelectronic devices [7-9]. The advantages can be quite substantial. Researchers in Korea successfully used silver nanoparticles to obtain a 38% increase in performance of blue LEDs by using silver nanoparticles embedded in p-GaN [10]. The researchers attribute the improvement to an increase in the spontaneous emission rate through resonance coupling between the excitons in multiple quantum wells and localized surface plasmons in the silver nanoparticles. In their work reported in this issue Kostya Ostrikov and his co-authors bridge the link between microplasma-assisted electrochemical process parameters and the plasmonic response. As they point out, 'This is an important experimental step towards bringing together plasma chemistry and plasmonics' [1]. All-gas-phase plasma approaches have already been demonstrated for the synthesis of nanoparticles of other metals. X D Pi and colleagues from the University of Minnesota demonstrated how one simple gas-phase process could produce stable silicon nanocrystal emitters with tailored size and surface functionalization [11]. Previously silicon nanocrystals had been prone to emission instabilities in air. Now Ostrikov and colleagues at the University of Sydney, CSIRO Materials Science and Engineering in Australia and the Key Laboratory for Laser Plasmas in China have studied microplasma-assisted electrochemical synthesis of Ag nanoparticles for plasmonic applications [1]. The synthesis uses moderate temperatures and atmospheric pressures and does not involve any toxic reducing agents. In addition they demonstrate how it allows control over nanoparticle size and interparticle spacing to optimize performance in device applications. Despite the overlap in plasma physics and the origins of plasmonic phenomena, studies of the relationship between plasma electrochemical synthesis and the plasmonic properties of nanoparticles have been limited until now. Yet Kostya Ostrikov and colleagues place particular emphasis on the potential of research at 'the intersection of reactive plasma chemistry and plasmonics'. While navigating the maze of intertwining disciplines that feed into nanotechnology research can be daunting, as this research highlights, great insights and advances may be gained where the different strands of research connect. References [1] Huang X Z, Zhong X X, Lu Y, Li Y S, Rider A E, Furman S A and Ostrikov K 2013 Plasmonic Ag nanoparticles via environment-benign atmospheric microplasma electrochemistry Nanotechnology 24 095604 [2] Sun Y and Xia Y 2002 Shape-controlled synthesis of gold and silver nanoparticles Science 298 2176-9 [3] Hulteen J C, Treichel D A, Smith M T, Duval M L, Jensen T R and Van Duyne R P 1999 Nanosphere lithography: size-tunable silver nanoparticle and surface cluster arrays J. Phys. Chem. B 103 3854-63 [4] Huang J et al 2007 Biosynthesis of silver and gold nanoparticles by novel sundried Cinnamomum camphora leaf Nanotechnology 18 105104 [5] Ma K, Cui Q, Liu G, Wu F, Xu S and Shao Y 2011 DNA abasic site-directed formation of fluorescent silver nanoclusters for selective nucleobase recognition Nanotechnology 22 305502 [6] Ali M E, Hashim U, Mustafa S, Che Man Y B, Yusop M H M, Bari M F, Islam Kh N and Hasan M F 2011 Nanoparticle sensor for label free detection of swine DNA in mixed biological samples Nanotechnology 22 195503 [7] Berini P, Olivieri A and Chen C 2012 Thin Au surface plasmon waveguide Schottky detectors on p-Si Nanotechnology 23 444011 [8] Reilly T H III, Van De Lagemaat J, Tenent R C, Morfa A J and Rowlen K L 2008 Surface-plasmon enhanced transparent electrodes in organic photovoltaics Appl. Phys. Lett. 92 243304 [9] Bialiayeu A, Bottomley A, Prezgot D, Ianoul A and Albert J 2012 Plasmon-enhanced refractometry using silver nanowire coatings on tilted fibre Bragg gratings Nanotechnology 23 444012 [10] Cho C-Y, Kwon M-K, Lee S-J, Han S-H, Kang J-W, Kang S-E, Lee D-Y and Park S-J 2010 Surface plasmon-enhanced light-emitting diodes using silver nanoparticles embedded in p-GaN Nanotechnology 21 205201 [11] Pi X D, Liptak R W, Deneen N J, Wells N P, Carter C B, Campbell S A and Kortshagen U 2008 Air-stable full-visible-spectrum emission from silicon nanocrystals synthesized by an all-gas-phase plasma approach Nanotechnology 19 245603

  8. EDITORIAL: Announcing the 2009 Measurement Science and Technology Outstanding Paper Awards Announcing the 2009 Measurement Science and Technology Outstanding Paper Awards

    NASA Astrophysics Data System (ADS)

    Foss, John; Dewhurst, Richard; Fujii, Kenichi; Regtien, Paul

    2010-06-01

    Since 1991, Measurement Science and Technology has awarded a Best Paper prize. The Editorial Board of this journal believes that such a prize is an opportunity to thank authors for submitting their work, and serves as an integral part of the on-going quality review of the journal. The current breadth of topical areas that are covered by MST has made it advisable to expand the recognition of excellent publications. Hence, since 2005 the Editorial Board have presented 'Outstanding Paper Awards' in four subject categories: Fluid Mechanics; Measurement Science; Precision Measurements; and Sensors and Sensing Systems. This year also saw the introduction of a new category—Optical and Laser-based Techniques. 2009 Award Winners—Fluid Mechanics Digital particle image velocimetry (DPIV) robust phase correlation Adric Eckstein and Pavlos P Vlachos Department of Mechanical Engineering, Virginia Tech, Blacksburg, VA, USA This paper [1] represents a valuable improvement to the phase-only correlation technique (first proposed by Wernet in this journal in 2005 (Wernet M 2005 Symmetric phase-only filtering: a new paradigm for DPIV data processing Meas. Sci. Technol. 16 601-18) for particle-image-velocimetry (PIV) measurements of fluid flow. The authors establish a sound theoretical foundation and clearly describe the working principle of their robust phase correlation method. The methodology for assessing performance is excellent. Detailed results on several internationally recognized PIV test cases are presented. The robust phase correlation method is of general applicability and therefore can be expected to have substantial impact in this very active area of fluid-mechanics measurements. 2009 Award Winner—Precision Measurement A nanonewton force facility and a novel method for measurements of the air and vacuum permittivity at zero frequencies V Nesterov Physikalisch-Technische Bundesanstalt (PTB), Bundesallee 100, D-38116 Braunschweig, Germany This paper [2] describes a new method for measuring the air and vacuum permittivity by observing a nanonewton force in a disk-pendulum. The frequency dependence of the vacuum permittivity, ɛ0, has been one of the fundamental questions in physics. Although it is confidently believed that there is no frequency dependence in ɛ0, very few experiments have been conducted to verify the properties of ɛ0. Especially in the region near zero frequencies, no experiment has been done in the vacuum. The precise measurement of the vacuum permittivity is therefore of fundamental interest to test the correctness of Maxwell's equations in an electrostatic field. In this paper, the author developed a new principle using a disk-pendulum, where the displacement of the disk-pendulum in the presence of an electrostatic field has been detected by optical interferometry. The nanonewton forces generated by the electrostatic field have been measured to evaluate the air and vacuum permittivity at zero frequencies, achieving a relative standard uncertainty of 10-5 in the measurement of ɛ0. The measurement system developed here also opened a new way for the force standard in the nanonewton region, investigation of the Casimir effect, direct measurement of laser power etc. This paper has been downloaded more than 200 times since its publication. The selection committee members on precision measurement selected this paper from a strongly competitive list of eleven candidates for its sophisticated idea, originality in apparatus, and excellent result with uncertainty evaluation. Considering its impact on fundamental physics and also on precision force measurement in the nanonewton region, the paper was nominated for the MST Precision Measurement Award from the papers published in 2009. 2009 Award Winners—Sensors and Sensing Systems High-resolution and compact refractometer for salinity measurements D Malardé, Z Y Wu, P Grosso, J-L de Bougrenet de la Tocnaye and M Le Menn Optics Department, UMR CNRS 6082 FOTON, TELECOM Bretagne, CS 83818, 29238 Brest Cédex 3, France Laboratoire de Métrologie et de Chimie Océanographique, SHOM 13 rue du Châtelier, BP 30316, 29603 Brest Cedex, France The absolute salinity of seawater is an important component in the determination of the ocean's thermodynamic properties. This paper [3] presents a measurement system for very accurate determination of the salinity. The method is based on measuring the refractive index of seawater, a parameter that is related to the salinity. Although the method is essentially simple: using a prism and a PSD for direct measurement of the angle of refraction, the refraction also depends on many more parameters (temperature, pressure, wavelength). Moreover, for obtaining accurate salinity values, a high resolution of the refractive index is required, of the order of 10-7, under all possible conditions. Starting with a list of notations and symbols, the paper follows with an overview of existing methods for salinity measurements and their performances. Next, the principle based on refractometry is introduced, and a theoretical model is presented, comprising a large number of parameters that influence the properties of the refractometer. From this analysis there follows an optimization of the geometry of the device. The sensitivity for salinity and other water parameters are estimated from theory, and verified experimentally. Salinity measurements are compared with those using standard salinometers, and show an uncertainty less than a few 10-3 psu (practical salinity units). The obtained resolution is about 4 × 10-7, which is limited by that of the readout electronics of the PSD. It is demonstrated that this can be further improved to achieve the required resolution lower than 10-7. The authors make clear that their prototype, the length of which is about 12 cm, is an important step to a fully in situ oceanographic salinometer, but further testing is required to confirm reliability. Indeed, the paper does not report on long term effects of, for instance, contamination of the optical parts. Hopefully this will be investigated and published in the next stage of the research. 2009 Award Winners—Measurement Science Analysis and mitigation of measurement uncertainties in the traceability chain for the calibration of photovoltaic devices Harald Mullejans, Willem Zaaiman and Roberto Galleano European Commission, Joint Research Centre, Institute for Energy, Renewable Energy Unit, European Solar Test Installation, Via E Fermi 2749, I-21027 Ispra (Va), Italy The energy output and efficiency from different types of photovoltaic (PV) devices is an essential characteristic of photovoltaics. They may only be assessed from cell performance under standard test conditions, with traceability back to international standards. As this paper [4] points out in its introduction, the reliability of the measurements and their uncertainty are of crucial importance to manufacturers, operators and investors. Several features in the format of the article help to make this an excellent paper. Following an informative abstract, the paper has a concise introduction followed by a detailed formulation of the problem to be addressed. After a discussion of present-day international codes related to the measurement and performance of PVs, the paper goes on to describe one of the most difficult issues in traceability, that of deriving an irradiance quantity which is normally measured by a reference PV device. This might appear straightforward, but the paper highlights the difficulties of measuring the irradiance of sunlight (either simulated or natural) during the evaluation of the electrical performance of PV devices. The calibration of any PV device essentially consists of the measurement of the IV characteristics, by sweeping the device from its short-circuit condition (SC) to its open-circuit condition (OC) when exposed to (pulsed or continuous) simulated or natural sunlight. In this paper, all measurements were carried out at the European Solar Test Installation at Ispra in Italy. After describing the measurement methods, the authors discuss at length the calculations of measurement uncertainty. This leads to a rigorous discussion of relative uncertainties from measurement parameters. Uncertainties arise from a range of parameters that include small contributions from electrical, temperature and fill factor parameters. But the greatest arises from uncertainties both in the optical source and in the reference cell. As a consequence, the authors make a convincing case both for identifying the sources of uncertainty and for reducing overall uncertainties from +/-2.6% to below +/-2%. The conclusions are concise, and the paper is rounded off with a list of 34 references with several papers cited from 2005 onwards. This paper was rated as excellent by external referees, and has been downloaded several hundred times since its publication. It is one of 30 papers nominated this year in the Measurement Science category, and gained most votes from those short-listed. The discussion on measurement uncertainty sets a fine example to all researchers involved in experimental measurement science. 2009 Award Winners—Optical and Laser-based Techniques Measurement of tiny droplets using a newly developed optical fibre probe micro-fabricated by a femtosecond pulse laser T Saito, K Matsuda, Y Ozawa, S Oishi and S Aoshima Shizuoka University, 3-5-1 Johoku, Naka-ku Hamamatsu, Shizuoka 432-8561, Japan CRL, Hamamatsu Photonics K.K., 5000 Hirakuchi, Hamakita-ku Hamamatsu, Shizuoka 434-8601, Japan This Award goes to a paper [5] describing a fascinating and novel optical fibre probe applied to measurements in gas-liquid two-phase flows. Optical probes have already been widely applied to two-phase flows. These include the use of four-tip optical probes (F-TOP) for millimetre-size bubbles/droplets, and a single-tip optical fibre probe (S-TOP) for sub-millimetre size bubbles/droplets. This new paper describes how micro-machining a groove into the side of the silica fibre using a femtosecond laser system leads to a new optical fibre probe (Fs-TOP). It is capable of measurements of velocity and size of droplets down to about 50 µm in diameter. A useful introduction describes the importance of characterization required in gas-liquid two-phase flows. Measurements are required in a variety of research fields, e.g. sprays, automotive engines, fine chemistry and atomic power plants. Characterization of bubbles/droplets at high density has been desired for both laboratory and industrial use. Addressed towards this goal, this paper describes the use of optical fibre probes that have been modified with a side-wall groove. The authors point out that whereas the S-TOP is made very easily, with the tip of the S-TOP only micro-ground into a wedge shape, the Fs-TOP is very difficult to fabricate. In addition to a wedge tip, fabrication involves a femtosecond laser system with nano-order six-axis automatic optical stages and confocal optics. Hence it is important to intelligently select between these two types of probe depending on the measurement objective. Moreover, like all types of new probe, it is first necessary to validate its performance against other probes with accepted performance characteristics. After describing the experimental arrangement, the authors discuss at length the performance of the new Fs-TOP and that of the S-TOP for comparison. Additionally, results from the Fs-TOP are compared with those from visualization of the droplets by a high-speed video camera. Results show satisfactory agreement. After a lengthy presentation of results and discussion, the authors produce a concise set of inclusions, including a summary of the small perturbation in droplet size arising from the presence of the probe. The paper was one of 22 papers nominated this year for the Best Paper Award in Optical and Laser-based Techniques. It crosses the disciplines of optical measurement science and measurements required for the characterization of two-phase fluid flow. Exploiting new technological facilities in micromachining, the paper is an excellent example of new opportunities that may arise in measurement. References [1] Eckstein A and Vlachos P P 2009 Digital particle image velocimetry (DPIV) robust phase correlation Meas. Sci. Technol. 20 055401 (14pp) [2] Nesterov V 2009 A nanonewton force facility and a novel method for measurements of the air and vacuum permittivity at zero frequencies Meas. Sci. Technol. 20 084012 (6pp) [3] Malardé D, Wu Z Y, Grosso P, de Bougrenet de la Tocnaye J-L and Le Menn M 2009 High-resolution and compact refractometer for salinity measurements Meas. Sci. Technol. 20 015204 (8pp) [4] Müllejans H, Zaaiman W and Galleano R 2009 Analysis and mitigation of measurement uncertainties in the traceability chain for the calibration of photovoltaic devices Meas. Sci. Technol. 20 075101 (12pp) [5] Saito T, Matsuda K, Ozawa Y, Oishi S and Aoshima S 2009 Measurement of tiny droplets using a newly developed optical fibre probe micro-fabricated by a femtosecond pulse laser Meas. Sci. Technol. 20 114002 (12pp)

Top