The Super Efficient Refrigerator Program: Case study of a Golden Carrot program
DOE Office of Scientific and Technical Information (OSTI.GOV)
Eckert, J B
1995-07-01
The work in this report was conducted by the Analytic Studies Division (ASD) of the National Renewable Energy Laboratory (NREL) for the U.S. Department of Energy Office of Energy Efficiency and Renewable Energy, Office of Building Technologies. This case study describes the development and implementation of the Super Efficient Refrigerator Program (SERP), which awarded $30 million to the refrigerator manufacturer that developed and commercialized a refrigerator that exceeded 1993 federal efficiency standards by at least 25%. The program was funded by 24 public and private utilities. As the first Golden Carrot program to be implemented in the United States, SERPmore » was studied as an example for future `market-pull` efforts.« less
Peng, Shengmeng; Du, Tao; Wu, Wanhua; Chen, Xianju; Lai, Yiming; Zhu, Dingjun; Wang, Qiong; Ma, Xiaoming; Lin, Chunhao; Li, Zean; Guo, Zhenghui; Huang, Hai
2018-06-11
The aim of this study was to investigate the associations of serine proteinase inhibitor family G1 (SERPING1) down-regulation with poor prognosis in patients with prostate cancer (PCa). Furthermore, we aim to find more novel and effective PCa molecular markers to provide an early screening of PCa, distinguish patients with aggressive PCa, predict the prognosis, or reduce the economic burden of PCa. SERPING1 protein expression in both human PCa and normal prostate tissues was detected by immunohistochemical staining, which intensity was analyzed in association with clinical pathological parameters such Gleason score, pathological grade, clinical stage, tumor stage, lymph node metastasis, and distant metastasis. Moreover, we used The Cancer Genome Atlas (TCGA) Database, Taylor Database, and Oncomine dataset to validate our immunohistochemical results and investigated the value of SERPING1 in PCa at mRNA level. Kaplan-Meier analysis and Cox regression analysis were performed to evaluate the relationship between SERPING1 and prognosis of patients with PCa. The outcome showed that SERPING1 was expressed mainly in cytoplasm of grand cells of prostate tissue and was significantly expressed less in PCa (P<0.001). Furthermore, in the tissue microarray of our samples, decreasing expression of SERPING1 was correlated with the higher Gleason score (P = 0.004), the higher pathological grade (P = 0.01) and the advanced tumor stage (P = 0.005) at protein level. In TCGA dataset and Taylor Dataset, low-expressed SERPING1 was correlated with the younger patient (P = 0.02 in TCGA, P = 0.044 in Taylor) and the higher Gleason score (P = 0.019 in TCGA, P<0.001 in Taylor) at mRNA level. Kaplan-Meier analysis revealed that the lower mRNA of SERPING1 predicted lower overall survivals (P = 0.027 in TCGA), lower disease-free survival (P = 0.029) and lower biochemical recurrence-free survival (P = 0.011 in Taylor). Data from Oncomine database shown that SERPING1 low expression implying higher malignancy of prostate lesions. Using multivariate analysis, we also found that SERPING1 expression was independent prognostic marker of poor disease-free survival and biochemical recurrence-free survival. SERPING1 may play an important role in PCa and can be serve as a novel marker in diagnosis and prognostic prediction in PCa. In addition, levels of SERPING1 can help identify low-risk prostate to provide reference for patients with PCa to accept active surveillance and reduce overtreatment. Copyright © 2018 Elsevier Inc. All rights reserved.
Spagnol, Gaelle; Kieken, Fabien; Kopanic, Jennifer L.; Li, Hanjun; Zach, Sydney; Stauch, Kelly L.; Grosely, Rosslyn; Sorgen, Paul L.
2016-01-01
Neuronal precursor cell-expressed developmentally down-regulated 4 (Nedd4) was the first ubiquitin protein ligase identified to interact with connexin43 (Cx43), and its suppressed expression results in accumulation of gap junction plaques at the plasma membrane. Nedd4-mediated ubiquitination of Cx43 is required to recruit Eps15 and target Cx43 to the endocytic pathway. Although the Cx43 residues that undergo ubiquitination are still unknown, in this study we address other unresolved questions pertaining to the molecular mechanisms mediating the direct interaction between Nedd4 (WW1–3 domains) and Cx43 (carboxyl terminus (CT)). All three WW domains display a similar three antiparallel β-strand structure and interact with the same Cx43CT 283PPXY286 sequence. Although Tyr286 is essential for the interaction, MAPK phosphorylation of the preceding serine residues (Ser(P)279 and Ser(P)282) increases the binding affinity by 2-fold for the WW domains (WW2 > WW3 ≫ WW1). The structure of the WW2·Cx43CT276–289(Ser(P)279, Ser(P)282) complex reveals that coordination of Ser(P)282 with the end of β-strand 3 enables Ser(P)279 to interact with the back face of β-strand 3 (Tyr286 is on the front face) and loop 2, forming a horseshoe-shaped arrangement. The close sequence identity of WW2 with WW1 and WW3 residues that interact with the Cx43CT PPXY motif and Ser(P)279/Ser(P)282 strongly suggests that the significantly lower binding affinity of WW1 is the result of a more rigid structure. This study presents the first structure illustrating how phosphorylation of the Cx43CT domain helps mediate the interaction with a molecular partner involved in gap junction regulation. PMID:26841867
Spagnol, Gaelle; Kieken, Fabien; Kopanic, Jennifer L; Li, Hanjun; Zach, Sydney; Stauch, Kelly L; Grosely, Rosslyn; Sorgen, Paul L
2016-04-01
Neuronal precursor cell-expressed developmentally down-regulated 4 (Nedd4) was the first ubiquitin protein ligase identified to interact with connexin43 (Cx43), and its suppressed expression results in accumulation of gap junction plaques at the plasma membrane. Nedd4-mediated ubiquitination of Cx43 is required to recruit Eps15 and target Cx43 to the endocytic pathway. Although the Cx43 residues that undergo ubiquitination are still unknown, in this study we address other unresolved questions pertaining to the molecular mechanisms mediating the direct interaction between Nedd4 (WW1-3 domains) and Cx43 (carboxyl terminus (CT)). All three WW domains display a similar three antiparallel β-strand structure and interact with the same Cx43CT(283)PPXY(286)sequence. Although Tyr(286)is essential for the interaction, MAPK phosphorylation of the preceding serine residues (Ser(P)(279)and Ser(P)(282)) increases the binding affinity by 2-fold for the WW domains (WW2 > WW3 ≫ WW1). The structure of the WW2·Cx43CT(276-289)(Ser(P)(279), Ser(P)(282)) complex reveals that coordination of Ser(P)(282)with the end of β-strand 3 enables Ser(P)(279)to interact with the back face of β-strand 3 (Tyr(286)is on the front face) and loop 2, forming a horseshoe-shaped arrangement. The close sequence identity of WW2 with WW1 and WW3 residues that interact with the Cx43CT PPXY motif and Ser(P)(279)/Ser(P)(282)strongly suggests that the significantly lower binding affinity of WW1 is the result of a more rigid structure. This study presents the first structure illustrating how phosphorylation of the Cx43CT domain helps mediate the interaction with a molecular partner involved in gap junction regulation. © 2016 by The American Society for Biochemistry and Molecular Biology, Inc.
Hançer, Nancy J.; Qiu, Wei; Cherella, Christine; Li, Yedan; Copps, Kyle D.; White, Morris F.
2014-01-01
IRS1 and IRS2 are key substrates of the insulin receptor tyrosine kinase. Mass spectrometry reveals more than 50 phosphorylated IRS1 serine and threonine residues (Ser(P)/Thr(P) residues) in IRS1 from insulin-stimulated cells or human tissues. We investigated a subset of IRS1 Ser(P)/Thr(P) residues using a newly developed panel of 25 phospho-specific monoclonal antibodies (αpS/TmAbIrs1). CHO cells overexpressing the human insulin receptor and rat IRS1 were stimulated with insulin in the absence or presence of inhibitors of the PI3K → Akt → mechanistic target of rapamycin (mTOR) → S6 kinase or MEK pathways. Nearly all IRS1 Ser(P)/Thr(P) residues were stimulated by insulin and significantly suppressed by PI3K inhibition; fewer were suppressed by Akt or mTOR inhibition, and none were suppressed by MEK inhibition. Insulin-stimulated Irs1 tyrosine phosphorylation (Tyr(P)Irs1) was enhanced by inhibition of the PI3K → Akt → mTOR pathway and correlated with decreased Ser(P)-302Irs1, Ser(P)-307Irs1, Ser(P)-318Irs1, Ser(P)-325Irs1, and Ser(P)-346Irs1. Metabolic stress modeled by anisomycin, thapsigargin, or tunicamycin increased many of the same Ser(P)/Thr(P) residues as insulin, some of which (Ser(P)-302Irs1, Ser(P)-307Irs1, and four others) correlated significantly with impaired insulin-stimulated Tyr(P)Irs1. Thus, IRS1 Ser(P)/Thr(P) is an integrated response to insulin stimulation and metabolic stress, which associates with reduced Tyr(P)Irs1 in CHOIR/IRS1 cells. PMID:24652289
SITE TECHNOLOGY CAPSULE: IN SITU STEAM ENHANCED RECOVERY PROCESS
The SERP technology is designed to treat soils contaminated with VOCs and SVOCs in situ. Steam injection and vacuum extraction are used to remove the organic compounds from the soil and concentrate them for disposal or recycling. A full-scale demonstration of SERP was conducted a...
ERIC Educational Resources Information Center
Cox, Robyn; O'Brien, Katherine; Walsh, Maureen; West, Helen
2015-01-01
This paper reports on a 10 week vocabulary focused intervention based on the Word Generation program (Snow, 2002, 2010; SERP, 2011) in primary and secondary schools, which demonstrated clear improvements, particularly with students who are EAL/D learners. Teachers across English, Science, Maths and Social Sciences developed professional learning…
Design-Based Research within the Constraints of Practice: AlgebraByExample
ERIC Educational Resources Information Center
Booth, Julie L.; Cooper, Laura A.; Donovan, M. Suzanne; Huyghe, Alexandra; Koedinger, Kenneth R.; Paré-Blagoev, E. Juliana
2015-01-01
Superintendents from districts in the Minority Student Achievement Network (MSAN) challenged the Strategic Education Research Partnership (SERP) to identify an approach to narrowing the minority student achievement gap in Algebra 1 without isolating minority students for intervention. SERP partnered with 8 MSAN districts and researchers from 3…
Adding a Visualization Feature to Web Search Engines: It’s Time
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wong, Pak C.
Since the first world wide web (WWW) search engine quietly entered our lives in 1994, the “information need” behind web searching has rapidly grown into a multi-billion dollar business that dominates the internet landscape, drives e-commerce traffic, propels global economy, and affects the lives of the whole human race. Today’s search engines are faster, smarter, and more powerful than those released just a few years ago. With the vast investment pouring into research and development by leading web technology providers and the intense emotion behind corporate slogans such as “win the web” or “take back the web,” I can’t helpmore » but ask why are we still using the very same “text-only” interface that was used 13 years ago to browse our search engine results pages (SERPs)? Why has the SERP interface technology lagged so far behind in the web evolution when the corresponding search technology has advanced so rapidly? In this article I explore some current SERP interface issues, suggest a simple but practical visual-based interface design approach, and argue why a visual approach can be a strong candidate for tomorrow’s SERP interface.« less
ERIC Educational Resources Information Center
Snow, Catherine E.; Lawrence, Joshua F.
2011-01-01
When the Strategic Education Research Partnership (SERP) began working with Boston Public Schools (BPS) in 2005, the most pressing need articulated by the district was research and development in the area of middle school literacy. Thus SERP researchers undertook to specify more precisely what the middle school literacy problem in BPS was by…
Andrejević, Slađana; Korošec, Peter; Šilar, Mira; Košnik, Mitja; Mijanović, Radovan; Bonači-Nikolić, Branka; Rijavec, Matija
2015-01-01
Hereditary angioedema due to C1 inhibitor deficiency (C1-INH-HAE) is a rare autosomal dominant disease characterized by recurrent life-threatening oedemas and/or abdominal pain and caused by mutations affecting the C1 inhibitor gene, SERPING1. We sought to investigate the spectrum of SERPING1 mutations in Serbia and the possible genotype-phenotype association. C1-INH-HAE was diagnosed on the basis of clinical and laboratory criteria in 40 patients from 27 families; four were asymptomatic. Mutational analysis of the SERPING1 gene was performed by sequencing and multiplex ligation-dependent probe amplification. Disease-causing mutations in SERPING1 were identified in all patients. In C1-INH-HAE type I, we identified 19 different mutations, including 6 missense mutations, 6 nonsense mutations, 2 small deletions, 1 small insertion, 2 splicing defects and 2 large deletions. Two of the mutations (c.300C>T and c.1184_1185insTA) are reported here for the first time. All C1-INH-HAE type II patients from three families harboured the same substitution (c.1396C>T). Based on the type of mutation identified in the SERPING1 gene, patients were divided into two groups: group 1 (nonsense, frameshift, large deletions/insertions, splicing defect, and mutations at Arg444) or group 2 (missense, excluding mutations at Arg444). Significant differences were found in the clinical severity score (P = 0.005), prevalence of laryngeal (P = 0.040) and facial (P = 0.013) oedema, and long-term prophylaxis (P = 0.023) between the groups with different types of mutations. Because our population consisted of related subjects, differences in the severity score between mutation groups were further confirmed using the generalized estimating equation (P = 0.038). Our study identified 20 different disease-causing mutations, including two novel mutations, in all C1-INH-HAE patients, highlighting the heterogeneity of mutations in the SERPING1 gene. Furthermore, it appears that mutations with a clear effect on C1-INH function might be responsible for a more severe disease phenotype. PMID:26535898
Andrejević, Slađana; Korošec, Peter; Šilar, Mira; Košnik, Mitja; Mijanović, Radovan; Bonači-Nikolić, Branka; Rijavec, Matija
2015-01-01
Hereditary angioedema due to C1 inhibitor deficiency (C1-INH-HAE) is a rare autosomal dominant disease characterized by recurrent life-threatening oedemas and/or abdominal pain and caused by mutations affecting the C1 inhibitor gene, SERPING1. We sought to investigate the spectrum of SERPING1 mutations in Serbia and the possible genotype-phenotype association. C1-INH-HAE was diagnosed on the basis of clinical and laboratory criteria in 40 patients from 27 families; four were asymptomatic. Mutational analysis of the SERPING1 gene was performed by sequencing and multiplex ligation-dependent probe amplification. Disease-causing mutations in SERPING1 were identified in all patients. In C1-INH-HAE type I, we identified 19 different mutations, including 6 missense mutations, 6 nonsense mutations, 2 small deletions, 1 small insertion, 2 splicing defects and 2 large deletions. Two of the mutations (c.300C>T and c.1184_1185insTA) are reported here for the first time. All C1-INH-HAE type II patients from three families harboured the same substitution (c.1396C>T). Based on the type of mutation identified in the SERPING1 gene, patients were divided into two groups: group 1 (nonsense, frameshift, large deletions/insertions, splicing defect, and mutations at Arg444) or group 2 (missense, excluding mutations at Arg444). Significant differences were found in the clinical severity score (P = 0.005), prevalence of laryngeal (P = 0.040) and facial (P = 0.013) oedema, and long-term prophylaxis (P = 0.023) between the groups with different types of mutations. Because our population consisted of related subjects, differences in the severity score between mutation groups were further confirmed using the generalized estimating equation (P = 0.038). Our study identified 20 different disease-causing mutations, including two novel mutations, in all C1-INH-HAE patients, highlighting the heterogeneity of mutations in the SERPING1 gene. Furthermore, it appears that mutations with a clear effect on C1-INH function might be responsible for a more severe disease phenotype.
Karadža-Lapić, Ljerka; Korošec, Peter; Šilar, Mira; Košnik, Mitja; Cikojević, Draško; Lozić, Bernarda; Rijavec, Matija
2016-11-01
Hereditary angioedema due to C1 inhibitor deficiency (C1-INH-HAE) is a rare autosomal dominant disease caused by mutations in the SERPING1 gene. It can affect many regions in the body, but potentially life-threatening laryngeal oedemas are of concern. Twenty-three subjects from two families were recruited for clinical data evaluation and molecular analysis at General Hospital Šibenik, Croatia. Decreased levels of C1 inhibitor were detected in 12 adult patients and three young asymptomatic persons. The same novel deletion of two nucleotides on exon 3 (c.74_75delAT) was identified in all of them. A history of laryngeal oedema was present in 10 patients (83%), and all patients reported laryngeal attacks at least once a year. The delay in diagnosis decreased noticeably from the first to the last generation. We identified a novel causative mutation in SERPING1 in several affected members of two apparently unrelated families with a high frequency of laryngeal oedema. Molecular analysis of large C1-INH-HAE families will provide new insights on the genotype-phenotype relationship. Key messages Hereditary angioedema due to C1 inhibitor deficiency is a rare autosomal dominant disease caused by mutations in the SERPING1 gene, and laryngeal oedema is of concern because it can cause death by asphyxiation. A novel causative mutation in SERPING1, a deletion of two nucleotides on exon 3 (c.74_75delAT), was identified in several affected members of two apparently unrelated families with a high frequency of laryngeal oedema. Molecular analysis of large C1-INH-HAE families will provide new insights on the genotype-phenotype relationship because it appears that the mutation type may affect disease severity.
Cooney, Adeline; O'Shea, Eamon; Casey, Dympna; Murphy, Kathy; Dempsey, Laura; Smyth, Siobhan; Hunter, Andrew; Murphy, Edel; Devane, Declan; Jordan, Fionnuala
2013-07-01
This paper describes the steps used in developing and piloting a structured education programme - the Structured Education Reminiscence-based Programme for Staff (SERPS). The programme aimed to prepare nurses and care assistants to use reminiscence when caring for people with dementia living in long-term care. Reminiscence involves facilitating people to talk or think about their past. Structured education programmes are used widely as interventions in randomised controlled trials. However, the process of developing a structured education programme has received little attention relative to that given to evaluating the effectiveness of such programmes. This paper makes explicit the steps followed to develop the SERPS, thereby making a contribution to the methodology of designing and implementing effective structured education programmes. The approach to designing the SERPS was informed by the Van Meijel et al. (2004) model (Journal of Advanced Nursing 48, 84): (1) problem definition, (2) accumulation of building blocks for intervention design, (3) intervention design and (4) intervention validation. Grounded theory was used (1) to generate data to shape the 'building blocks' for the SERPS and (2) to explore residents, family and staff's experience of using/receiving reminiscence. Analysis of the pilot data indicated that the programme met its objective of preparing staff to use reminiscence with residents with dementia. Staff were positive both about the SERPS and the use of reminiscence with residents with dementia. This paper outlines a systematic approach to developing and validating a structured education programme. Participation in a structured education programme is more positive for staff if they are expected to actively implement what they have learnt. Ongoing support during the delivery of the programme is important for successful implementation. The incorporation of client and professional experience in the design phase is a key strength of this approach to programme design. © 2012 Blackwell Publishing Ltd.
The effect of complexing phosphoproteins to decalcified collagen on in vitro calcification.
Endo, A; Glimcher, M J
1989-01-01
Decalcified samples of chicken bone containing phosphoproteins of varying concentrations were used to assess the effect of phosphoproteins and of protein-bound Ser(P) and Thr(P) in the in vitro nucleation of a Ca-P solid phase from metastable solutions of Ca and P. Phosphoproteins of bone as well as the phosphoproteins from egg yolk (phosvitin) were used. Increasing concentrations of phosphoprotein [as measured by the amount of protein bound Ser(P) and Thr(P)] in the decalcified bone particles significantly reduced the time required for nucleation to occur after exposure to metastable solutions of Ca and P (decreased operational lag times). Treatment with wheat germ acid phosphatase markedly reduced the concentration of Ser(P) and Thr(P) in the decalcified bone samples and in the decalcified bone collagen samples complexed with phosphoproteins (almost to zero). The loss of the organic phosphate groups significantly increased the operational lag time, but did not abolish nucleation of apatite crystals by the bone collagen fibrils essentially devoid of Ser(P) and Thr(P). Bone phosphoproteins were not specific; substitution of phosvitin for bone phosphoproteins as complexes with bone collagen also proved to be effective facilitators of nucleation, which was interesting since both types of phosphoproteins have certain common chemical and structural characteristics. Noncollagenous components other than phosphoproteins were present in the decalcified bone samples. However, the marked dependence of the lag time on the Ser(P) and Thr(P) concentrations and the very marked diminution in the efficacy of the nucleation phenomenon as a result of treatment with wheat germ acid phosphatase, clearly suggests that the organic phosphate residues of the phosphoproteins play a direct and significant role in the process of in vitro nucleation of a solid phase of Ca and P (apatite) by bone collagen, and by implication, possibly in in vivo mineralization as well.
Hereditary Angioedema Nationwide Study in Slovenia Reveals Four Novel Mutations in SERPING1 Gene
Rijavec, Matija; Korošec, Peter; Šilar, Mira; Zidarn, Mihaela; Miljković, Jovan; Košnik, Mitja
2013-01-01
Hereditary angioedema (HAE) is a rare autosomal dominant disease characterized by swelling of the face, lips, tongue, larynx, genitalia, or extremities, with abdominal pain caused by intra-abdominal edema. HAE is caused by mutations affecting the C1 inhibitor gene, SERPING1, resulting in low levels of C1 inhibitor (Type I HAE) or normal levels of ineffective C1 inhibitor (Type II HAE). A nationwide survey identified nine unrelated families with HAE in Slovenia, among whom 17 individuals from eight families were recruited for genetic analyses. A diagnosis of HAE was established in the presence of clinical and laboratory criteria (low C1 inhibitor antigenic levels and/or function), followed up by a positive family history. Genetic studies were carried out using PCR and sequencing to detect SERPING1 mutations in promoter, noncoding exon 1, the 7 coding exons, and exon-intron boundaries. Multiplex ligation-dependent probe amplification was performed in order to search for large deletions/duplications in SERPING1 gene. A mutation responsible for HAE was identified in patients from seven families with the disease. In HAE type I families, one previously reported substitution (Gln67Stop, c.265C>T) and four novel mutations were identified. The new mutations included two missense substitutions, Ser128Phe (c.449C>T), and Glu429Lys (c.1351G>A), together with two frameshift mutations, indel (c.49delGinsTT) and deletion (c.593_594delCT). Both families with HAE type II harbored the two well-known substitutions affecting the arginyl residue at the reactive center in exon 8, Arg444Cys (c.1396C>T) and Arg444His (c.1397G>A), respectively. In one patient only the homozygous variant g.566T>C (c.-21T>C) was identified. Our study identified four novel mutations in the Slovenian HAE population, highlighting the heterogeneity of mutations in the SERPING1 gene causing C1 inhibitor deficiency and HAE. In a single patient with HAE a homozygous variant g.566T>C (c.-21T>C) might be responsible for the disease. PMID:23437219
Hereditary angioedema nationwide study in Slovenia reveals four novel mutations in SERPING1 gene.
Rijavec, Matija; Korošec, Peter; Šilar, Mira; Zidarn, Mihaela; Miljković, Jovan; Košnik, Mitja
2013-01-01
Hereditary angioedema (HAE) is a rare autosomal dominant disease characterized by swelling of the face, lips, tongue, larynx, genitalia, or extremities, with abdominal pain caused by intra-abdominal edema. HAE is caused by mutations affecting the C1 inhibitor gene, SERPING1, resulting in low levels of C1 inhibitor (Type I HAE) or normal levels of ineffective C1 inhibitor (Type II HAE). A nationwide survey identified nine unrelated families with HAE in Slovenia, among whom 17 individuals from eight families were recruited for genetic analyses. A diagnosis of HAE was established in the presence of clinical and laboratory criteria (low C1 inhibitor antigenic levels and/or function), followed up by a positive family history. Genetic studies were carried out using PCR and sequencing to detect SERPING1 mutations in promoter, noncoding exon 1, the 7 coding exons, and exon-intron boundaries. Multiplex ligation-dependent probe amplification was performed in order to search for large deletions/duplications in SERPING1 gene. A mutation responsible for HAE was identified in patients from seven families with the disease. In HAE type I families, one previously reported substitution (Gln67Stop, c.265C>T) and four novel mutations were identified. The new mutations included two missense substitutions, Ser128Phe (c.449C>T), and Glu429Lys (c.1351G>A), together with two frameshift mutations, indel (c.49delGinsTT) and deletion (c.593_594delCT). Both families with HAE type II harbored the two well-known substitutions affecting the arginyl residue at the reactive center in exon 8, Arg444Cys (c.1396C>T) and Arg444His (c.1397G>A), respectively. In one patient only the homozygous variant g.566T>C (c.-21T>C) was identified. Our study identified four novel mutations in the Slovenian HAE population, highlighting the heterogeneity of mutations in the SERPING1 gene causing C1 inhibitor deficiency and HAE. In a single patient with HAE a homozygous variant g.566T>C (c.-21T>C) might be responsible for the disease.
Kuo, Ching-Ying; Li, Xu; Kong, Xiang-Qian; Luo, Cheng; Chang, Che-Chang; Chung, Yiyin; Shih, Hsiu-Ming; Li, Keqin Kathy; Ann, David K
2014-07-25
Krüppel-associated box domain-associated protein 1 (KAP1) is a universal transcriptional corepressor that undergoes multiple posttranslational modifications (PTMs), including SUMOylation and Ser-824 phosphorylation. However, the functional interplay of KAP1 PTMs in regulating KAP1 turnover during DNA damage response remains unclear. To decipher the role and cross-talk of multiple KAP1 PTMs, we show here that DNA double strand break-induced KAP1 Ser-824 phosphorylation promoted the recruitment of small ubiquitin-like modifier (SUMO)-targeted ubiquitin E3 ligase, ring finger protein 4 (RNF4), and subsequent RNF4-mediated, SUMO-dependent degradation. Besides the SUMO interacting motif (SIM), a previously unrecognized, but evolutionarily conserved, arginine-rich motif (ARM) in RNF4 acts as a novel recognition motif for selective target recruitment. Results from combined mutagenesis and computational modeling studies suggest that RNF4 utilizes concerted bimodular recognition, namely SIM for Lys-676 SUMOylation and ARM for Ser(P)-824 of simultaneously phosphorylated and SUMOylated KAP1 (Ser(P)-824-SUMO-KAP1). Furthermore, we proved that arginines 73 and 74 within the ARM of RNF4 are required for efficient recruitment to KAP1 or accelerated degradation of promyelocytic leukemia protein (PML) under stress. In parallel, results of bimolecular fluorescence complementation assays validated the role of the ARM in recognizing Ser(P)-824 in living cells. Taken together, we establish that the ARM is required for RNF4 to efficiently target Ser(P)-824-SUMO-KAP1, conferring ubiquitin Lys-48-mediated proteasomal degradation in the context of double strand breaks. The conservation of such a motif may possibly explain the requirement for timely substrate selectivity determination among a myriad of SUMOylated proteins under stress conditions. Thus, the ARM dynamically regulates the SIM-dependent recruitment of targets to RNF4, which could be critical to dynamically fine-tune the abundance of Ser(P)-824-SUMO-KAP1 and, potentially, other SUMOylated proteins during DNA damage response. © 2014 by The American Society for Biochemistry and Molecular Biology, Inc.
Kuo, Ching-Ying; Li, Xu; Kong, Xiang-Qian; Luo, Cheng; Chang, Che-Chang; Chung, Yiyin; Shih, Hsiu-Ming; Li, Keqin Kathy; Ann, David K.
2014-01-01
Krüppel-associated box domain-associated protein 1 (KAP1) is a universal transcriptional corepressor that undergoes multiple posttranslational modifications (PTMs), including SUMOylation and Ser-824 phosphorylation. However, the functional interplay of KAP1 PTMs in regulating KAP1 turnover during DNA damage response remains unclear. To decipher the role and cross-talk of multiple KAP1 PTMs, we show here that DNA double strand break-induced KAP1 Ser-824 phosphorylation promoted the recruitment of small ubiquitin-like modifier (SUMO)-targeted ubiquitin E3 ligase, ring finger protein 4 (RNF4), and subsequent RNF4-mediated, SUMO-dependent degradation. Besides the SUMO interacting motif (SIM), a previously unrecognized, but evolutionarily conserved, arginine-rich motif (ARM) in RNF4 acts as a novel recognition motif for selective target recruitment. Results from combined mutagenesis and computational modeling studies suggest that RNF4 utilizes concerted bimodular recognition, namely SIM for Lys-676 SUMOylation and ARM for Ser(P)-824 of simultaneously phosphorylated and SUMOylated KAP1 (Ser(P)-824-SUMO-KAP1). Furthermore, we proved that arginines 73 and 74 within the ARM of RNF4 are required for efficient recruitment to KAP1 or accelerated degradation of promyelocytic leukemia protein (PML) under stress. In parallel, results of bimolecular fluorescence complementation assays validated the role of the ARM in recognizing Ser(P)-824 in living cells. Taken together, we establish that the ARM is required for RNF4 to efficiently target Ser(P)-824-SUMO-KAP1, conferring ubiquitin Lys-48-mediated proteasomal degradation in the context of double strand breaks. The conservation of such a motif may possibly explain the requirement for timely substrate selectivity determination among a myriad of SUMOylated proteins under stress conditions. Thus, the ARM dynamically regulates the SIM-dependent recruitment of targets to RNF4, which could be critical to dynamically fine-tune the abundance of Ser(P)-824-SUMO-KAP1 and, potentially, other SUMOylated proteins during DNA damage response. PMID:24907272
Gupta, Deepak; Haber, Halim
2014-06-01
Despite the variable results of published studies, it is imperative for ambulatory surgery centers to self-audit local cost-implications for post-operative nausea and vomiting (PONV) management. Our retrospective cost-audit assessed if there were comparative peri-anesthesia care cost-trends among patients who had undergone Low-Emetogenicity-Risk Procedures (LERP), Moderate-Emetogenicity-Risk Procedures (MERP) and Severe-Emetogenicity-Risk Procedures (SERP). This study was a review of Same Day Surgery Center practices in an academic university hospital setting during a three-year period (2010-2012). The patient lists were accessed from CIS and CITRIX App Bar for time audit and OR (operating room) schedule reports. Subsequently, OR pharmacy department ran a search for peri-operative anti-emetics and opioids that were billed for the patients at Same Day Surgery Center for the review period. The primary outcomes were the comparative costs/charges of these medications and comparative durations/ charges for these patients' stay in the post-anesthesia care unit (PACU). Secondary outcomes analyzed in the study included peri-anesthesia durations. A total of 8,657 patient records were analyzed. Almost all analyzed variables revealed statistically significant inter-variable positive correlations. The patients' age was significantly (P < 0.001) different among LERP/MERP/SERP patients (LERP: 48.8 +/- 14.7 years; MERP: 61.8 +/- 14.6 years; SERP: 51.3 +/- 14.5 years). In regards to primary and secondary outcomes, the statistical significant differences among LERP/MERP/SERP patients (after correcting for both patients' age as well as patients' sex) were only achieved for preoperative times (P = 0.002; Power = 0.9), operating room recovery times (P = 0.003; Power = 0.9), PACU stay times (P < 0.001; Power = 1.0), and PACU charges (P < 0.001; Power = 1.0). PACU stay times and PACU charges were significantly higher in patients who had undergone SERP as compared to patients who had undergone LERP or MERP at our Same Day Surgery Center.
Robles, J; Pedroso, E; Grandas, A
1995-01-01
The synthesis of a nucleopeptide with the sequence -Ser(p5'CATCAT)-Gly-Asp- has been undertaken by either convergent or stepwise solid-phase strategies, both of which use base-labile permanent protecting groups. The coupling of phosphitylated protected peptides onto oligonucleotide-resins did not afford the desired nucleopeptide, which was nevertheless obtained after oligonucleotide elongation at the hydroxyl group of the resin-bound peptide and deprotection under mild basic conditions. A preliminary study on the stability of different nucleopeptides to bases is also reported. PMID:7479079
Federal Register 2010, 2011, 2012, 2013, 2014
2012-12-31
... Energy Conservation Program: Certification of Commercial and Industrial HVAC, Refrigeration and Water... provisions for commercial refrigeration equipment; commercial heating, ventilating, air-conditioning (HVAC..., the Department extended the compliance date for certification of commercial refrigeration equipment...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kurnik, Charles W.; Keeling, Josh; Bruchs, Doug
Refrigerator recycling programs are designed to save energy by removing operable, albeit less efficient, refrigerators from service. By offering free pickup, providing incentives, and disseminating information about the operating cost of less efficient refrigerators, these programs are designed to encourage consumers to: - Limit the use of secondary refrigerators -Relinquish refrigerators previously used as primary units when they are replaced (rather than keeping the existing refrigerator as a secondary unit) -Prevent the continued use of less efficient refrigerators in another household through a direct transfer (giving it away or selling it) or indirect transfer (resale on the used appliance market).more » Commonly implemented by third-party contractors (who collect and decommission participating appliances), these programs generate energy savings through the retirement of inefficient appliances. The decommissioning process captures environmentally harmful refrigerants and foam, and enables recycling of the plastic, metal, and wiring components.« less
Becker, Annemarie H.; Oh, Eugene; Weissman, Jonathan S.; Kramer, Günter; Bukau, Bernd
2014-01-01
A plethora of factors is involved in the maturation of newly synthesized proteins, including chaperones, membrane targeting factors, and enzymes. Many factors act cotranslationally through association with ribosome-nascent chain complexes (RNCs), but their target specificities and modes of action remain poorly understood. We developed selective ribosome profiling (SeRP) to identify substrate pools and points of RNC engagement of these factors. SeRP is based on sequencing mRNA fragments covered by translating ribosomes (general ribosome profiling, RP), combined with a procedure to selectively isolate RNCs whose nascent polypeptides are associated with the factor of interest. Factor–RNC interactions are stabilized by crosslinking, the resulting factor–RNC adducts are then nuclease-treated to generate monosomes, and affinity-purified. The ribosome-extracted mRNA footprints are converted to DNA libraries for deep sequencing. The protocol is specified for general RP and SeRP in bacteria. It was first applied to the chaperone trigger factor and is readily adaptable to other cotranslationally acting factors, including eukaryotic factors. Factor–RNC purification and sequencing library preparation takes 7–8 days, sequencing and data analysis can be completed in 5–6 days. PMID:24136347
Commercial Refrigeration Technology. Florida Vocational Program Guide.
ERIC Educational Resources Information Center
University of South Florida, Tampa. Dept. of Adult and Vocational Education.
The program guide for commercial refrigeration technology courses in Florida identifies primary considerations for the organization, operation, and evaluation of a vocational education program. Following an occupational description for the job title for refrigeration mechanic, and its Dictionary of Occupational Titles code, are six sections…
Federal Register 2010, 2011, 2012, 2013, 2014
2010-07-15
... Conservation Program: Re-Opening of the Public Comment Period for Commercial Refrigeration Equipment AGENCY... document for commercial refrigeration equipment and provide notice of a public meeting. The NOPM provided... the framework document for commercial refrigeration equipment is to be re-opened from July 15, 2010 to...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shrestha, Som S; Vineyard, Edward Allan; Mumpower, Kevin
In response to environmental concerns raised by the use of refrigerants with high Global Warming Potential (GWP), the Air-Conditioning, Heating, and Refrigeration Institute (AHRI) has launched an industry-wide cooperative research program, referred to as the Low-GWP Alternative Refrigerants Evaluation Program (AREP), to identify and evaluate promising alternative refrigerants for major product categories. After successfully completing the first phase of the program in December 2013, AHRI launched a second phase of the Low-GWP AREP in 2014 to continue research in areas that were not previously addressed, including refrigerants in high ambient conditions, refrigerants in applications not tested in the first phase,more » and new refrigerants identified since testing for the program began. Although the Ozone Depletion Potential of R-410A is zero, this refrigerant is under scrutiny due to its high GWP. Several candidate alternative refrigerants have already demonstrated low global warming potential. Performance of these low-GWP alternative refrigerants is being evaluated for Air conditioning and heat pump applications to ensure acceptable system capacity and efficiency. This paper reports the results of a series of compressor calorimeter tests conducted for the second phase of the AREP to evaluate the performance of R-410A alternative refrigerants in a reciprocating compressor designed for air conditioning systems. It compares performance of alternative refrigerants ARM-71A, L41-1, DR-5A, D2Y-60, and R-32 to that of R-410A over a wide range of operating conditions. The tests showed that, in general, cooling capacities were slightly lower (except for the R-32), but energy efficiency ratios (EER) of the alternative refrigerants were comparable to that of R-410A.« less
Air Conditioning and Refrigeration Program Articulation, 1981-1982.
ERIC Educational Resources Information Center
Dallas County Community Coll. District, TX.
Based on a survey of high school programs and courses in the Dallas County Community College District (DCCCD), this articulated program is designed to prepare students for entry-level employment in the air conditioning and refrigeration industry, including residential and commercial air conditioning and commercial refrigeration. The skills and…
Simulation of Transcritical CO2 Refrigeration System with Booster Hot Gas Bypass in Tropical Climate
NASA Astrophysics Data System (ADS)
Santosa, I. D. M. C.; Sudirman; Waisnawa, IGNS; Sunu, PW; Temaja, IW
2018-01-01
A Simulation computer becomes significant important for performance analysis since there is high cost and time allocation to build an experimental rig, especially for CO2 refrigeration system. Besides, to modify the rig also need additional cos and time. One of computer program simulation that is very eligible to refrigeration system is Engineering Equation System (EES). In term of CO2 refrigeration system, environmental issues becomes priority on the refrigeration system development since the Carbon dioxide (CO2) is natural and clean refrigerant. This study aims is to analysis the EES simulation effectiveness to perform CO2 transcritical refrigeration system with booster hot gas bypass in high outdoor temperature. The research was carried out by theoretical study and numerical analysis of the refrigeration system using the EES program. Data input and simulation validation were obtained from experimental and secondary data. The result showed that the coefficient of performance (COP) decreased gradually with the outdoor temperature variation increasing. The results show the program can calculate the performance of the refrigeration system with quick running time and accurate. So, it will be significant important for the preliminary reference to improve the CO2 refrigeration system design for the hot climate temperature.
Caohuy, Hung; Yang, Qingfeng; Eudy, Yvonne; Ha, Thien-An; Xu, Andrew E.; Glover, Matthew; Frizzell, Raymond A.; Jozwik, Catherine; Pollard, Harvey B.
2014-01-01
Cystic fibrosis (CF) is due to a folding defect in the CF transmembrane conductance regulator (CFTR) protein. The most common mutation, ΔF508, prevents CFTR from trafficking to the apical plasma membrane. Here we show that activation of the PDK1/SGK1 signaling pathway with C4-ceramide (C4-CER), a non-toxic small molecule, functionally corrects the trafficking defect in both cultured CF cells and primary epithelial cell explants from CF patients. The mechanism of C4-CER action involves a series of mutual autophosphorylation and phosphorylation events between PDK1 and SGK1. Detailed mechanistic studies indicate that C4-CER initially induces autophosphorylation of SGK1 at Ser422. SGK1[Ser(P)422] and C4-CER coincidently bind PDK1 and permit PDK1 to autophosphorylate at Ser241. Then PDK1[Ser(P)241] phosphorylates SGK1[Ser(P)422] at Thr256 to generate fully activated SGK1[Ser422, Thr(P)256]. SGK1[Ser(P)422,Thr(P)256] phosphorylates and inactivates the E3 ubiquitin ligase Nedd4-2. ΔF508-CFTR is thus free to traffic to the plasma membrane. Importantly, C4-CER-mediated activation of both PDK1 and SGK1 is independent of the PI3K/Akt/mammalian target of rapamycin signaling pathway. Physiologically, C4-CER significantly increases maturation and stability of ΔF508-CFTR (t½ ∼10 h), enhances cAMP-activated chloride secretion, and suppresses hypersecretion of interleukin-8 (IL-8). We suggest that candidate drugs for CF directed against the PDK1/SGK1 signaling pathway, such as C4-CER, provide a novel therapeutic strategy for a life-limiting disorder that affects one child, on average, each day. PMID:25384981
Federal Register 2010, 2011, 2012, 2013, 2014
2010-05-06
... Availability of the Framework Document for Commercial Refrigeration Equipment AGENCY: Office of Energy... data collection process to consider amended energy conservation standards for commercial refrigeration... Energy, Building Technologies Program, Mailstop EE-2J, Framework Document for Commercial Refrigeration...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cook, K.
1995-01-01
This Innovative Technology Evaluation report summarizes the findings of an evaluation of the in situ Steam Enhanced Recovery Process (SERP) operated by Hughes Environmental Systems, Inc. at the Rainbow Disposal facility in Huntington Beach, California. The technology demonstration was conducted concurrent with a full-scale remedial action using the technology on an underground diesel leak. From this demonstration, it was concluded that the SERP process did not achieve the remedial goals desired at this site and there were significant operational problems. It is believed that these operational problems can be solved and substantially better performance can be attained. The cost ofmore » treatment was quite low, as expected with an in-situ process.« less
Compatibility of refrigerants and lubricants with elastomers. Final report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hamed, G.R.; Seiple, R.H.; Taikum, Orawan
1994-01-01
The information contained in this report is designed to assist the air-conditioning and refrigeration industry in the selection of suitable elastomeric gasket and seal materials that will prove useful in various refrigerant and refrigeration lubricant environments. In part I of the program the swell behavior in the test fluids has been determined using weight and in situ diameter measurements for the refrigerants and weight, diameter and thickness measurements for the lubricants. Weight and diameter measurements are repeated after 2 and 24 hours for samples removed fro the refrigerant test fluids and 24 hours after removal from the lubricants. Part IImore » of the testing program includes the evaluation of tensile strength, hardness, weight, and dimensional changes after immersion aging in refrigerant/lubricant mixtures of selected elastomer formulations at elevated temperature and pressure.« less
Computer program for determining the thermodynamic properties of Freon refrigerants
DOE Office of Scientific and Technical Information (OSTI.GOV)
Riemer, D.H.; Jacobs, H.R.; Boehm, R.F.
1977-12-01
This program was written to be used as a subroutine. The program determines the thermodynamics of Freon refrigerants. The following refrigerants can be analyzed F-11, F-12, F-13, F-14, F-21, F-22, F-23, F-113, and F-114. The subroutine can evaluate a thermodynamic state for these refrigerants given any of the following pairs of state quantities: pressure and quality, pressure and entropy, pressure and enthalpy, temperature and quality, temperature and specific volume, and temperature and pressure. These six pairs of knowns allow the user to analyze any thermodynamic cycle utilizing a refrigerant as the working fluid. The Downing form of the Martin equationmore » of state was used. This report contains a brief description, flow chart and listing of all subroutines required.« less
Computer program for determining the thermodynamic properties of freon refrigerants
DOE Office of Scientific and Technical Information (OSTI.GOV)
Riemer, D.H.; Jacobs, H.R.; Boehm, R.F.
1976-07-01
This program was written to be used as a subroutine. The program determines the thermodynamics of Freon refrigerants. The following refrigerants can be analyzed F-11, F-12, F-13, F-14, F-21, F-22, F-23, F-113, and F-114. The subroutine can evaluate a thermodynamic state for these refrigerants given any of the following pairs of state quantities: pressure and quality, pressure and entropy, pressure and enthalpy, temperature and quality, temperature and specific volume and temperature and pressure. These six pairs of knowns allow the user to analyze any thermodynamic cycle utilizing a refrigerant as the working fluid. The Downing form of the Martin equationmore » of state was used. A brief description, flow chart, and listing of all subroutines required are presented.« less
2010 Second Refrigerator Recycling Program NV Energy - Southern Nevada: Program Year 2010
This measurement and verification report provides measured and verified energy impacts achieved by the Second Refrigerator Recycling Program that NV Energy offered to its customers in southern Nevada during 2010.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-12-06
... Commercial and Industrial HVAC, Refrigeration and Water Heating Equipment AGENCY: Office of Energy Efficiency... extension to the compliance date for the certification provisions of commercial refrigeration equipment... refrigeration equipment; commercial HVAC equipment; commercial WH equipment; and walk-in coolers and freezers...
The purpose of this SOP is to assure suitable temperature maintenance in refrigerators and freezers used for sample storage during the Arizona NHEXAS project and the Border study. Keywords: lab; equipment; refrigerators and freezers.
The U.S.-Mexico Border Program is sponsored...
Analysis of Refrigeration Equipment in School Nutrition Programs in the USDA/FNS Southwest Region
ERIC Educational Resources Information Center
Webb, Virginia Susan
2012-01-01
Equipment to store foods at proper temperatures is critical to serving safe and nutritious meals in schools yet little is known about the amount or the adequacy of refrigerated storage in school nutrition programs. The purposes of this study were to identify the types and capacity of refrigeration equipment used in schools, determine the perceived…
Federal Register 2010, 2011, 2012, 2013, 2014
2011-09-15
... (collectively, ``refrigeration products''). 75 FR 78810. The amended test procedures for residential... Rule also included amendments to these procedures that will, once finalized, apply to refrigeration... period deadline to ``30 days after the [refrigeration products] standards final rule is made available to...
MicroRNA-124 expression counteracts pro-survival stress responses in glioblastoma.
Mucaj, V; Lee, S S; Skuli, N; Giannoukos, D N; Qiu, B; Eisinger-Mathason, T S K; Nakazawa, M S; Shay, J E S; Gopal, P P; Venneti, S; Lal, P; Minn, A J; Simon, M C; Mathew, L K
2015-04-23
Glioblastomas are aggressive adult brain tumors, characterized by inadequately organized vasculature and consequent nutrient and oxygen (O2)-depleted areas. Adaptation to low nutrients and hypoxia supports glioblastoma cell survival, progression and therapeutic resistance. However, specific mechanisms promoting cellular survival under nutrient and O2 deprivation remain incompletely understood. Here, we show that miR-124 expression is negatively correlated with a hypoxic gene signature in glioblastoma patient samples, suggesting that low miR-124 levels contribute to pro-survival adaptive pathways in this disease. As miR-124 expression is repressed in various cancer types (including glioblastoma), we quantified miR-124 abundance in normoxic and hypoxic regions in glioblastoma patient tissue, and investigated whether ectopic miR-124 expression compromises cell survival during tumor ischemia. Our results indicate that miR-124 levels are further diminished in hypoxic/ischemic regions within individual glioblastoma patient samples, compared with regions replete in O2 and nutrients. Importantly, we also show that increased miR-124 expression affects the ability of tumor cells to survive under O2 and/or nutrient deprivation. Moreover, miR-124 re-expression increases cell death in vivo and enhances the survival of mice bearing intracranial xenograft tumors. miR-124 exerts this phenotype in part by directly regulating TEAD1, MAPK14/p38α and SERP1, factors involved in cell proliferation and survival under stress. Simultaneous suppression of these miR-124 targets results in similar levels of cell death as caused by miR-124 restoration. Importantly, we further demonstrate that SERP1 reintroduction reverses the hypoxic cell death elicited by miR-124, indicating the importance of SERP1 in promoting tumor cell survival. In support of our experimental data, we observed a significant correlation between high SERP1 levels and poor patient outcome in glioblastoma patients. Collectively, among the many pro-tumorigeneic properties of miR-124 repression in glioblastoma, we delineated a novel role in promoting tumor cell survival under stressful microenvironments, thereby supporting tumor progression.
MicroRNA-124 expression counteracts pro-survival stress responses in glioblastoma
Mucaj, Vera; Lee, Samuel S.; Skuli, Nicolas; Giannoukos, Dionysios N.; Qiu, Bo; Eisinger-Mathason, T.S. Karin; Nakazawa, Michael S.; Shay, Jessica E.S.; Gopal, Pallavi P.; Venneti, Sriram; Lal, Priti; Minn, Andy J.; Simon, M. Celeste; Mathew, Lijoy K.
2014-01-01
Glioblastomas are aggressive adult brain tumors, characterized by inadequately organized vasculature and consequent nutrient and oxygen (O2)-depleted areas. Adaptation to low nutrients and hypoxia supports glioblastoma cell survival, progression, and therapeutic resistance. However, specific mechanisms promoting cellular survival under nutrient and O2 deprivation remain incompletely understood. Here, we show that miR-124 expression is negatively correlated with a hypoxic gene signature in glioblastoma patient samples, suggesting that low miR-124 levels contribute to pro-survival adaptive pathways in this disease. Since miR-124 expression is repressed in various cancers (including glioblastoma), we quantified miR-124 abundance in normoxic and hypoxic regions in glioblastoma patient tissue, and investigated whether ectopic miR-124 expression compromises cell survival, during tumor ischemia. Our results indicate that miR-124 levels are further diminished in hypoxic/ischemic regions within individual glioblastoma patient samples, compared to regions replete in O2 and nutrients. Importantly, we also show that increased miR-124 expression affects the ability of tumor cells to survive under O2 and/or nutrient deprivation. Moreover, miR-124 re-expression increases cell death in vivo, and enhances the survival of mice bearing intracranial xenograft tumors. miR-124 exerts this phenotype in part by directly regulating TEAD1, MAPK14/p38α and SERP1, factors involved in cell proliferation and survival under stress. Simultaneous suppression of these miR-124 targets results in similar levels of cell death as caused by miR-124 restoration. Importantly, we further demonstrate that SERP1 re-introduction reverses the hypoxic cell death elicited by miR-124, indicating the importance of SERP1 in promoting tumor cell survival. In support of our experimental data, we observed a significant correlation between high SERP1 levels and poor patient outcome in glioblastoma patients. Collectively, among the many pro-tumorigeneic properties of miR-124 repression in glioblastoma, we delineated a novel role in promoting tumor cell survival under stressful microenvironments, thereby supporting tumor progression. PMID:24954504
Public policies, private choices: Consumer desire and the practice of energy efficiency
NASA Astrophysics Data System (ADS)
Deumling, Reuben Alexander
Refrigerator energy consumption has been the subject of regulatory attention in the US for some thirty years. Federal product standards, energy labels, and a variety of programs to get consumers to discard their existing refrigerators sooner and buy new, more energy efficient ones have transformed the refrigerator landscape and changed how many of us think about refrigerators. The results of these policies are celebrated as a successful model for how to combine regulatory objectives and consumer preferences in pursuit of environmental outcomes where everyone wins. Yet per capita refrigerator energy consumption today remains (much) higher in the US than anywhere else, in part because energy efficiency overlooks the ways behavior, habit, emulation, social norms, advertising, and energy efficiency policies themselves shape energy consumption patterns. To understand these dynamics I investigate how people replacing their refrigerators through a state-sponsored energy efficiency program make sense of the choices facing them, and how various types of information designed to aid in this process (Consumer Reports tests, Energy Guide labels, rebate programs) frame the issue of responsible refrigerator consumption. Using interviews and archival research I examine how this information is used to script the choice of a refrigerator, whose priorities shape the form and content of these cues, and what the social meanings generated by and through encounters with refrigerators and energy efficiency are. I also helped build a model for estimating historic refrigerator energy consumption in the US, to measure the repercussions of refrigerator energy inefficiency. My focus in this dissertation is on the ways the pursuit of energy efficiency improvements for domestic refrigerators intersects with and sometimes reinforces escalating demand for energy. My research suggests that the practice of pursuing energy efficiency improvements in refrigerators subordinates the issue of refrigerator energy consumption---what factors influence it, how and why it fluctuated historically, how to take it seriously---in pursuit of increased sales. The a priori assumption that consumers desire certain styles of refrigerator has become a compulsion to trade up. In evaluating the results of energy policies celebrating technical achievements without paying attention to the social dynamics which these regulations encounter is insufficient.
Additional information for food processors, food distributors, refrigerated warehouses, and any other facility with ammonia refrigeration system. Includes guidance on exemptions, threshold quantity, offsite consequence analysis.
REFLEAK: NIST Leak/Recharge Simulation Program for Refrigerant Mixtures
National Institute of Standards and Technology Data Gateway
SRD 73 NIST REFLEAK: NIST Leak/Recharge Simulation Program for Refrigerant Mixtures (PC database for purchase) REFLEAK estimates composition changes of zeotropic mixtures in leak and recharge processes.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-06-16
... sectors: Refrigeration and air-conditioning, foam blowing, aerosols, and sterilants. The majority of the... additional refrigerant alternatives as acceptable will provide users in the refrigeration and air... alternatives to HCFCs other than HCFC-22, HCFC-142b, and blends thereof? D. In servicing existing refrigeration...
Empirical models of scalp-EEG responses using non-concurrent intracranial responses
NASA Astrophysics Data System (ADS)
Kaur, Komalpreet; Shih, Jerry J.; Krusienski, Dean J.
2014-06-01
Objective. This study presents inter-subject models of scalp-recorded electroencephalographic (sEEG) event-related potentials (ERPs) using intracranially recorded ERPs from electrocorticography and stereotactic depth electrodes in the hippocampus, generally termed as intracranial EEG (iEEG). Approach. The participants were six patients with medically-intractable epilepsy that underwent temporary placement of intracranial electrode arrays to localize seizure foci. Participants performed one experimental session using a brain-computer interface matrix spelling paradigm controlled by sEEG prior to the iEEG electrode implantation, and one or more identical sessions controlled by iEEG after implantation. All participants were able to achieve excellent spelling accuracy using sEEG, four of the participants achieved roughly equivalent performance in the iEEG sessions, and all participants were significantly above chance accuracy for the iEEG sessions. The sERPs were modeled using a linear combination of iERPs using two different optimization criteria. Main results. The results indicate that sERPs can be accurately estimated from the iERPs for the patients that exhibited stable ERPs over the respective sessions, and that the transformed iERPs can be accurately classified with an sERP-derived classifier. Significance. The resulting models provide a new empirical representation of the formation and distribution of sERPs from underlying composite iERPs. These new insights provide a better understanding of ERP relationships and can potentially lead to the development of more robust signal processing methods for noninvasive EEG applications.
Appendix E: Supplemental Risk Management Program Guidance for Ammonia Refrigeration Facilities
Additional information for food processors, food distributors, refrigerated warehouses, and any other facility that has an ammonia refrigeration system. Includes details on exemption for farms, threshold quantity, and offsite consequence analysis.
Photovoltaic refrigeration application: Assessment of the near-term market
NASA Technical Reports Server (NTRS)
Rosenblum, L.; Bifano, W. J.; Poley, W. A.; Scudder, L. R.
1977-01-01
This foreign and domestic market assessment was performed as part of the Tests and Applications Project being conducted by NASA-LeRC as part of the Department of Energy's (DOE) National Photovoltaic Program. One of the objectives of that program was to stimulate the demand for photovoltaic power systems so that appropriate markets would be developed in concert with the increasing photovoltaic production capacity. The refrigeration application represented a possible market for photovoltaics; hence, a brief survey of potential applications was conducted. Both refrigerators and refrigeration systems were considered in the assessment although the primary emphasis is on refrigerators of 9 cu ft of less. Three user sectors were examined: (1) government, (2) commercial/institutional, and (3) general public.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-04-19
... provisions for commercial refrigeration equipment; commercial heating, ventilating, air- conditioning (HVAC... to meet that deadline. In particular, manufacturers of commercial refrigeration equipment; commercial... compliance date for filing complete certification reports for manufacturers of commercial refrigeration...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-06-30
... commercial refrigeration equipment; commercial heating, ventilating, air- conditioning (HVAC) equipment..., manufacturers of commercial refrigeration equipment; commercial HVAC equipment; commercial WH equipment; walk-in... extension to the compliance date for the certification provisions for commercial refrigeration equipment...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Abdelaziz, Omar; Shrestha, Som S.; Munk, Jeffrey D.
The Oak Ridge National Laboratory (ORNL) High-Ambient-Temperature Evaluation Program for low– global warming potential (Low-GWP) Refrigerants aims to develop an understanding of the performance of low-GWP alternative refrigerants to hydrochlorofluorocarbon (HCFC) and hydrofluorocarbon (HFC) refrigerants in mini-split air conditioners under high-ambient-temperature conditions. This final report describes the parties involved, the alternative refrigerant selection process, the test procedures, and the final results.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Abdelaziz, Omar; Shrestha, Som S.; Shen, Bo
The Oak Ridge National Laboratory (ORNL) High-Ambient-Temperature Evaluation Program for Low-Global Warming Potential (Low-GWP) Refrigerants aims to develop an understanding of the performance of low-GWP alternative refrigerants relative to hydrochlorofluorocarbon (HCFC) and hydrofluorocarbon (HFC) refrigerants in packaged or Rooftop Unit (RTU) air conditioners under high-ambient-temperature conditions. This final report describes the parties involved, the alternative refrigerants selection process, the test procedures, and the final results.
Arif, Nadia; Al-Jefri, Majed; Bizzi, Isabella Harb; Perano, Gianni Boitano; Goldman, Michel; Haq, Inam; Chua, Kee Leng; Mengozzi, Manuela; Neunez, Marie; Smith, Helen; Ghezzi, Pietro
2018-01-01
The 1998 Lancet paper by Wakefield et al., despite subsequent retraction and evidence indicating no causal link between vaccinations and autism, triggered significant parental concern. The aim of this study was to analyze the online information available on this topic. Using localized versions of Google, we searched "autism vaccine" in English, French, Italian, Portuguese, Mandarin, and Arabic and analyzed 200 websites for each search engine result page (SERP). A common feature was the newsworthiness of the topic, with news outlets representing 25-50% of the SERP, followed by unaffiliated websites (blogs, social media) that represented 27-41% and included most of the vaccine-negative websites. Between 12 and 24% of websites had a negative stance on vaccines, while most websites were pro-vaccine (43-70%). However, their ranking by Google varied. While in Google.com, the first vaccine-negative website was the 43rd in the SERP, there was one vaccine-negative webpage in the top 10 websites in both the British and Australian localized versions and in French and two in Italian, Portuguese, and Mandarin, suggesting that the information quality algorithm used by Google may work better in English. Many webpages mentioned celebrities in the context of the link between vaccines and autism, with Donald Trump most frequently. Few websites (1-5%) promoted complementary and alternative medicine (CAM) but 50-100% of these were also vaccine-negative suggesting that CAM users are more exposed to vaccine-negative information. This analysis highlights the need for monitoring the web for information impacting on vaccine uptake.
Cavallini, Annalisa; Brewerton, Suzanne; Bell, Amanda; Sargent, Samantha; Glover, Sarah; Hardy, Clare; Moore, Roger; Calley, John; Ramachandran, Devaki; Poidinger, Michael; Karran, Eric; Davies, Peter; Hutton, Michael; Szekeres, Philip; Bose, Suchira
2013-01-01
Neurofibrillary tangles, one of the hallmarks of Alzheimer disease (AD), are composed of paired helical filaments of abnormally hyperphosphorylated tau. The accumulation of these proteinaceous aggregates in AD correlates with synaptic loss and severity of dementia. Identifying the kinases involved in the pathological phosphorylation of tau may identify novel targets for AD. We used an unbiased approach to study the effect of 352 human kinases on their ability to phosphorylate tau at epitopes associated with AD. The kinases were overexpressed together with the longest form of human tau in human neuroblastoma cells. Levels of total and phosphorylated tau (epitopes Ser(P)-202, Thr(P)-231, Ser(P)-235, and Ser(P)-396/404) were measured in cell lysates using AlphaScreen assays. GSK3α, GSK3β, and MAPK13 were found to be the most active tau kinases, phosphorylating tau at all four epitopes. We further dissected the effects of GSK3α and GSK3β using pharmacological and genetic tools in hTau primary cortical neurons. Pathway analysis of the kinases identified in the screen suggested mechanisms for regulation of total tau levels and tau phosphorylation; for example, kinases that affect total tau levels do so by inhibition or activation of translation. A network fishing approach with the kinase hits identified other key molecules putatively involved in tau phosphorylation pathways, including the G-protein signaling through the Ras family of GTPases (MAPK family) pathway. The findings identify novel tau kinases and novel pathways that may be relevant for AD and other tauopathies. PMID:23798682
Federal Register 2010, 2011, 2012, 2013, 2014
2013-10-31
...: The U.S. Department of Energy (DOE) has preliminarily determined that wine chillers and other... Wine Chillers 2. Thermoelectric Refrigeration Products 3. Absorption Refrigeration Products V... to separate them from other miscellaneous residential refrigeration products such as wine chillers...
DESIGN AND OPTIMIZATION OF A REFRIGERATION SYSTEM
The paper discusses the design and optimization of a refrigeration system, using a mathematical model of a refrigeration system modified to allow its use with the optimization program. he model was developed using only algebraic equations so that it could be used with the optimiz...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shrestha, Som S; Sharma, Vishaldeep; Abdelaziz, Omar
In response to environmental concerns raised by the use of refrigerants with high Global Warming Potential (GWP), the Air-Conditioning, Heating, and Refrigeration Institute (AHRI) has launched an industry-wide cooperative research program, referred to as the Low-GWP Alternative Refrigerants Evaluation Program (AREP), to identify and evaluate promising alternative refrigerants for major product categories. This paper reports one of the Oak Ridge National Laboratory (ORNL) contributions to AREP. It compares performance of alternative refrigerants to that of R-410A and R-404A for heat pump and medium temperature applications, respectively. The alternatives reported in this paper are: R-32, DR-5, and L-41a for R-410A andmore » ARM-31a, D2Y-65, L-40, and a mixture of R-32 and R-134a for R-404A. All performance comparison tests were conducted using scroll compressors of ~1.85 tons (6.5 kW) cooling capacity. Tests were conducted over a range of combinations of saturation suction and saturation discharge temperatures for both compressors. The tests showed that, in general, energy efficiency ratio (EER) and cooling capacity of R-410A alternative refrigerants were slightly lower than that of the baseline refrigerant with a moderate increases in discharge temperature. On the other hand, R-404A alternative refrigerants showed relative performance dependence on saturation suction and saturation discharge temperatures and larger increases in discharge temperature than for the R-410A alternatives. This paper summarizes the relative performance of all alternative refrigerants compared to their respective baseline.« less
National Weatherization Assistance Program Evaluation: Assessment of Refrigerator Energy Use
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tonn, Bruce Edward; Goeltz, Rick
2015-03-01
This report assesses the energy consumption characteristics and performance of refrigerators that were monintored as a component of the Indoor Air Quality Study that itself was a component of the retrospective evaluation of the Department of Energy's Weatherization Assistance Program.
BIBLIOGRAPHY OF TRAINING AIDS.
ERIC Educational Resources Information Center
MCKEONE, CHARLES J.
THIS COMPILATION OF INSTRUCTIONAL AIDS FOR USE IN AIR-CONDITIONING AND REFRIGERATION TRAINING PROGRAMS CONTAINS LISTS OF VISUAL AND AUDIOVISUAL TRAINING AIDS AND GUEST LECTURERS AVAILABLE FROM MEMBER COMPANIES OF THE AIR-CONDITIONING AND REFRIGERATION INSTITUTE AS AN INDUSTRY SERVICE TO SCHOOL OFFICIALS INTERESTED IN CONDUCTING SUCH PROGRAMS. THE…
Refrigeration, Heating & Air Conditioning. Post Secondary Curriculum Guide.
ERIC Educational Resources Information Center
Garrison, Joe C.; And Others
This curriculum guide was designed for use in postsecondary refrigeration, heating and air conditioning education programs in Georgia. Its purpose is to provide for the development of entry level skills in refrigeration, heating, and air conditioning in the areas of air conditioning knowledge, theoretical structure, tool usage, diagnostic ability,…
The paper is a recapitulation of the experimental testing at the U.S. Environmental Protection Agency's NRMRL's (National Risk Management Research Laboratory's) Air Pollution Prevention and Control Division on residential refrigerator/freezers (R/Fs). R/F testing at the NRMRL lab...
The Oak Ridge Refrigerant Management Program
NASA Technical Reports Server (NTRS)
Kevil, Thomas H.
1995-01-01
For many years, chlorofluorocarbons (CFC's) have been used by the Department of Energy's (DOE) Oak Ridge Y-12 Plant in air conditioning and process refrigeration systems. However, Title 6 of the Clean Air Act Amendments (CAAA) and Executive Order 12843 (Procurement Requirements and Policies for Federal Agencies for Ozone Depleting Substances) signed by President Clinton require, as policy, that all federal agencies maximize their use of safe, alternate refrigerants and minimize, where economically practical, the use of Class 1 refrigerants. Unfortunately, many government facilities and industrial plants have no plan or strategy in place to make this changeover, even though their air conditioning and process refrigeration equipment may not be sustainable after CFC production ends December 31, 1995. The Y-12 Plant in Oak Ridge, Tennessee, has taken an aggressive approach to complying with the CAAA and is working with private industry and other government agencies to solve tough manufacturing and application problems associated with CFC and hydrochlorofluorocarbon (HCFC) alternatives. Y-12 was the first DOE Defense Program (DP) facility to develop a long-range Stratospheric Ozone Protection Plan for refrigerant management for compliance with the CAAA. It was also the first DOE DP facility to complete detailed engineering studies on retrofitting and replacing all air conditioning and process refrigeration equipment to enable operation with alternate refrigerants. The management plan and engineering studies are models for use by other government agencies, manufacturing plants, and private industry. This presentation identifies some of the hidden pitfalls to be encountered in the accelerated phaseout schedule of CFC's and explains how to overcome and prevent these problems. In addition, it outlines the general issues that must be considered when addressing the phase-out of ozone depleting substances and gives some 'lessons learned' by Y-12 from its Refrigerant Management Program. Discussion topics include requirements for developing a refrigerant management plan and establishing priorities for cost-effective compliance with the CAAA, as well as ways in which employees can be empowered to develop a comprehensive refrigerant management plan. The result of this employee empowerment was a cooperative labor-management effort that is beneficial for Y-12, DOE, and the environment.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-11-24
... Efficiency Program for Certain Commercial and Industrial Equipment: Test Procedures for Commercial Refrigeration Equipment AGENCY: Office of Energy Efficiency and Renewable Energy, Department of Energy. ACTION... amendments to its test procedure for commercial refrigeration equipment (CRE). The amendments would update...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shah, N. K.; Park, W. Y.; Gerke, B.
Improving the energy efficiency of room air conditioners (RACs) while transitioning to low global-warming-potential (GWP) refrigerants will be a critical step toward reducing the energy, peak load, and emissions impacts of RACs while keeping costs low. Previous research quantified the benefits of leapfrogging to high efficiency in tandem with the transition to low-GWP refrigerants for RACs (Shah et al., 2015) and identified opportunities for initial action to coordinate energy efficiency with refrigerant transition in economies constituting about 65% of the global RAC market (Shah et al., 2017). This report describes further research performed to identify the best-performing (i.e., most efficientmore » and low-GWP-refrigerant using) RACs on the market, to support an understanding of the best available technology (BAT). Understanding BAT can help support market-transformation programs for high-efficiency and low-GWP equipment such as minimum energy performance standards (MEPS), labeling, procurement, and incentive programs. We studied RACs available in six economies—China, Europe, India, Japan, South Korea, and the United States—that together account for about 70% of global RAC demand, as well as other emerging economies. The following are our key findings: • Highly efficient RACs using low-GWP refrigerants, e.g., HFC-32 (R-32) and HC-290 (R-290), are commercially available today at prices comparable to similar RACs using high-GWP HCFC-22 (R-22) or HFC-410A (R-410A). • High efficiency is typically a feature of high-end products. However, highly efficient, cost-competitive (less than 1,000 or 1,500 U.S. dollars in retail price, depending on size) RACs are available. • Where R-22 is being phased out, high GWP R-410A still dominates RAC sales in most mature markets except Japan, where R-32 dominates. • In all of the economies studied except Japan, only a few models are energy efficient and use low-GWP refrigerants. For example, in Europe, India, and Indonesia, the highest-efficiency RAC models employ the low-GWP refrigerants R-32 or R-290. • RACs are available in most regions and worldwide that surpass the highest efficiency levels recognized by labeling programs. • Fixed-speed RACs using high-GWP and ozone-depleting R-22 refrigerant still dominate the market in many emerging economies. There is significant scope to improve RAC efficiency and transition to low-GWP refrigerants using commercially available technology and to design market-transformation programs for high-efficiency, low-GWP equipment including standards, labeling, procurement, and incentive programs.« less
ERIC Educational Resources Information Center
Oil Belt Vocational Technical School, El Dorado, AR.
A multimedia, self-paced, individualized instructional program was designed to meet the needs of students in air conditioning, refrigeration, and heating programs at Oil Belt Vocational Technical School (Arkansas). The multimedia approach provided for video-based presentations to meet the needs for visual contact with the classroom and for…
Ames Research Center cryogenics program
NASA Technical Reports Server (NTRS)
Kittel, Peter
1987-01-01
Viewgraphs describe the Ames Research Center's cryogenics program. Diagrams are given of a fluid management system, a centrifugal pump, a flow meter, a liquid helium test facility, an extra-vehicular activity coupler concept, a dewar support with passive orbital disconnect, a pulse tube refrigerator, a dilution refrigerator, and an adiabatic demagnetization cooler.
Air Conditioning, Heating, and Refrigeration. Competency-Based Curriculum Manual.
ERIC Educational Resources Information Center
Gourley, Frank A., Jr.
This manual was developed to serve as an aid to administrators and instructors involved with postsecondary air conditioning, heating, and refrigeration programs. The first of six chapters contains general information on program implementation, the curriculum design, facilities and equipment requirements, and textbooks and references. Chapter 2…
Air Conditioning, Heating, and Refrigeration: Scope and Sequence.
ERIC Educational Resources Information Center
Nashville - Davidson County Metropolitan Public Schools, TN.
This scope and sequence guide, developed for an air conditioning, heating, and refrigeration vocational education program, represents an initial step in the development of a systemwide articulated curriculum sequence for all vocational programs within the Metropolitan Nashville Public School System. It was developed as a result of needs expressed…
78 FR 64295 - Energy Conservation Program: Test Procedure for Commercial Refrigeration Equipment
Federal Register 2010, 2011, 2012, 2013, 2014
2013-10-28
... amended under this section shall be reasonably designed to produce test results which measure energy... as members of the Working Group, in addition to two members from ASRAC, and one DOE representative... Energy Conservation Program: Test Procedure for Commercial Refrigeration Equipment; Proposed Rule #0;#0...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-12-02
... procedure for commercial refrigeration equipment because the equipment cannot operate at the specified... Program for certain industrial equipment, which includes commercial refrigeration equipment, the focus of... establish and amend test procedures for commercial refrigeration equipment. (42 U.S.C. 6314(a)(6)(C)) On...
Arif, Nadia; Al-Jefri, Majed; Bizzi, Isabella Harb; Perano, Gianni Boitano; Goldman, Michel; Haq, Inam; Chua, Kee Leng; Mengozzi, Manuela; Neunez, Marie; Smith, Helen; Ghezzi, Pietro
2018-01-01
The 1998 Lancet paper by Wakefield et al., despite subsequent retraction and evidence indicating no causal link between vaccinations and autism, triggered significant parental concern. The aim of this study was to analyze the online information available on this topic. Using localized versions of Google, we searched “autism vaccine” in English, French, Italian, Portuguese, Mandarin, and Arabic and analyzed 200 websites for each search engine result page (SERP). A common feature was the newsworthiness of the topic, with news outlets representing 25–50% of the SERP, followed by unaffiliated websites (blogs, social media) that represented 27–41% and included most of the vaccine-negative websites. Between 12 and 24% of websites had a negative stance on vaccines, while most websites were pro-vaccine (43–70%). However, their ranking by Google varied. While in Google.com, the first vaccine-negative website was the 43rd in the SERP, there was one vaccine-negative webpage in the top 10 websites in both the British and Australian localized versions and in French and two in Italian, Portuguese, and Mandarin, suggesting that the information quality algorithm used by Google may work better in English. Many webpages mentioned celebrities in the context of the link between vaccines and autism, with Donald Trump most frequently. Few websites (1–5%) promoted complementary and alternative medicine (CAM) but 50–100% of these were also vaccine-negative suggesting that CAM users are more exposed to vaccine-negative information. This analysis highlights the need for monitoring the web for information impacting on vaccine uptake. PMID:29922286
Ji, Qing; Wang, Wenhai; Luo, Yunquan; Cai, Feifei; Lu, Yiyu; Deng, Wanli; Li, Qi; Su, Shibing
2017-01-01
Systems biology and bioinformatics provide the feasibility for the basic research associated with “same traditional Chinese medicine (TCM) syndrome in different diseases”. In this study, the plasma proteins in postoperative colorectal (PCC) and postoperative liver cancer (PLC) patients with YDLKS (Yin deficiency of liver-kidney syndrome) were screened out using iTRAQ combined with LC-MS/MS technology. The results demonstrated that, KNG1, AMBP, SERPING1, etc, were all differentially expressed in both PCC and PLC patients with YDLKS, and associated closely with complement and coagulation cascades pathway. C7 and C2 were another two representative factors involving in former pathway. Further validation showed that, the C7 levels were increased significantly in PLC (P < 0.05) and PCC (P < 0.05) with YDLKS group compared to those of NS (no obvious TCM syndromes) group. The AMBP levels were down-regulated significantly in PLC with YDLKS group compared to those of PCC with YDLKS group (P < 0.05). The significant differences of SERPING1 levels (and C2 levels) were shown between YDLKS and NS in PCC (P < 0.01). There were also significant differences of C2 levels between PCC and PLC patients with YDLKS (P < 0.05). Moreover, significant differences of C2 levels were also found between PLC and PCC patients with YDLKS (P < 0.01). ROC curves indicated that, C7 and SERPING1 independently had a potential diagnostic value in distinguishing YDLKS from NS in PLC and PCC, providing the evidences for the material basis of “same TCM syndrome in different diseases” in PCC and PLC patients with YDLKS. PMID:29262557
Ji, Qing; Wang, Wenhai; Luo, Yunquan; Cai, Feifei; Lu, Yiyu; Deng, Wanli; Li, Qi; Su, Shibing
2017-11-28
Systems biology and bioinformatics provide the feasibility for the basic research associated with "same traditional Chinese medicine (TCM) syndrome in different diseases". In this study, the plasma proteins in postoperative colorectal (PCC) and postoperative liver cancer (PLC) patients with YDLKS (Yin deficiency of liver-kidney syndrome) were screened out using iTRAQ combined with LC-MS/MS technology. The results demonstrated that, KNG1, AMBP, SERPING1, etc, were all differentially expressed in both PCC and PLC patients with YDLKS, and associated closely with complement and coagulation cascades pathway. C7 and C2 were another two representative factors involving in former pathway. Further validation showed that, the C7 levels were increased significantly in PLC ( P < 0.05) and PCC ( P < 0.05) with YDLKS group compared to those of NS (no obvious TCM syndromes) group. The AMBP levels were down-regulated significantly in PLC with YDLKS group compared to those of PCC with YDLKS group ( P < 0.05). The significant differences of SERPING1 levels (and C2 levels) were shown between YDLKS and NS in PCC ( P < 0.01). There were also significant differences of C2 levels between PCC and PLC patients with YDLKS ( P < 0.05). Moreover, significant differences of C2 levels were also found between PLC and PCC patients with YDLKS ( P < 0.01). ROC curves indicated that, C7 and SERPING1 independently had a potential diagnostic value in distinguishing YDLKS from NS in PLC and PCC, providing the evidences for the material basis of "same TCM syndrome in different diseases" in PCC and PLC patients with YDLKS.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-09-27
...The Energy Policy and Conservation Act (EPCA) prescribes energy conservation standards for various consumer products and commercial and industrial equipment, including residential refrigerators, refrigerator-freezers, and freezers. EPCA also requires the U.S. Department of Energy (DOE) to determine whether more stringent, amended standards for these products are technologically feasible and economically justified, and would save a significant amount of energy. In this NOPR, DOE proposes amended energy conservation standards for residential refrigerators, refrigerator- freezers, and freezers. The NOPR also announces a public meeting to receive comment on these proposed standards and associated analyses and results.
This Innovative Technology Evaluation report summarizes the findings of an evaluation of the in situ Steam Enhanced Recovery Process (SERP) operated by Hughes Environmental Systems, Inc. at the Rainbow Disposal facility in Huntington Beach, California. he technology demonstration...
DEMONSTRATION BULLETIN: IN SITU STEAM ENHANCED RECOVERY PROCESS - HUGHES ENVIRONMENTAL SYSTEMS, INC.
The Steam Enhanced Recovery Process (SERP) is designed to remove volatile compounds such as halogenated solvents and petroleum hydrocarbons, and semi-volatile compounds from contaminated soils in situ. The vapor pressures of most contaminants will increase by the addition of ste...
40 CFR 35.3580 - Environmental review requirements.
Code of Federal Regulations, 2011 CFR
2011-07-01
... costs. A State must conduct an environmental review which considers the impacts of a project based on... this subpart. (h) Modifications to approved SERPs. Significant changes to State environmental review... 40 Protection of Environment 1 2011-07-01 2011-07-01 false Environmental review requirements. 35...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ryadovikov, V. N., E-mail: riadovikov@ihep.ru; Aleev, A. N.; Ardashev, E. N.
2016-03-15
The results of an analysis of data from the SERP-E-184 experiment devoted to studying mechanisms of the production of charmed particles in proton–nucleus interactions at 70 GeV and their decays are presented. The data in question were obtained upon irradiating the SVD-2 active target consisting of carbon, silicon, and lead plates with a beam of 70-GeV protons. A detailed simulation on the basis of the FRITIOF7.02 and GEANT3.21 code packages made it possible to optimize event-selection criteria and to calculate the detection efficiency for Λ{sub c}{sup +} baryons. After selecting a signal from the threebody decay of a Λ{sub c}{supmore » +} baryon, the inclusive cross section for its production at near-threshold energies, its lifetime, and the parameter of the A dependence of the cross section were found. The Λ{sub c}{sup +} -baryon yields are tabulated along with data from other experiments and theoretical predictions.« less
Federal Register 2010, 2011, 2012, 2013, 2014
2010-08-19
... General Electric Company (GE) a waiver from the DOE electric refrigerator and refrigerator-freezer test... procedure that takes this technology into account when measuring energy consumption. DATES: This Decision.... Department of Energy, Building Technologies Program, Mailstop EE-2J, 1000 Independence Avenue, SW...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-08-19
... Electronics, Inc. (LG) a waiver from the DOE electric refrigerator and refrigerator- freezer test procedure... takes this technology into account when measuring energy consumption. DATES: This Decision and Order is... Energy, Building Technologies Program, Mailstop EE-2J, 1000 Independence Avenue, SW., Washington, DC...
Vapor Compression Cycle Design Program (CYCLE_D)
National Institute of Standards and Technology Data Gateway
SRD 49 NIST Vapor Compression Cycle Design Program (CYCLE_D) (PC database for purchase) The CYCLE_D database package simulates the vapor compression refrigeration cycles. It is fully compatible with REFPROP 9.0 and covers the 62 single-compound refrigerants . Fluids can be used in mixtures comprising up to five components.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-10-21
..., and refrigeration systems. See 76 FR 21580 (April 15, 2011) (final rule prescribing walk-in test...-Conditioning, Heating, and Refrigeration Institute (AHRI) did not agree with DOE's proposal to set the test... manufacturers to provide the panel's U-factor if the panel manufacturer is not providing refrigeration systems...
ERIC Educational Resources Information Center
Alberta Advanced Education and Technology, 2012
2012-01-01
The graduate of the Transport Refrigeration Technician apprenticeship program is a certified journeyperson who will be able: (1) to diagnose repair, maintain and operate transport refrigeration equipment used to heat or cool the load as well as of diesel engines, APUs and other prime movers; (2) to use tools and equipment in order to carry out…
Federal Register 2010, 2011, 2012, 2013, 2014
2012-01-11
... of a central air conditioner which is designed to remove the heat absorbed by the refrigerant and to... heat absorbed by the refrigerant and to transfer it to the outside environment, and which consists of... pump that is designed to transfer heat between the refrigerant and the outdoor air, and which consists...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-06-14
.... The waiver is specific to the Daikin VRV III-PB variable refrigerant flow (VRF) multi-split commercial... this notice to test and rate its VRV III-PB variable refrigerant flow (VRF) multi-split commercial heat... Institute (ANSI/ AHRI) Standard 1230-2010, ``Performance Rating of Variable Refrigerant Flow (VRF) Multi...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Abdelaziz, Omar; Munk, Jeffrey D.; Shrestha, Som S.
The Oak Ridge National Laboratory (ORNL) High-Ambient Temperature Testing Program for Low-GWP Refrigerants aims to develop an understanding of the performance of low-Global Warming Potential (low-GWP) alternatives to Hydrochlorofluorocarbon (HCFC) and Hydrofluorocarbon (HFC) refrigerants in mini-split air conditioners under high ambient temperature conditions. This interim working paper describes the parties involved, the alternative refrigerants selection process, the test procedures, and the preliminary results.
The LSST Camera 500 watt -130 degC Mixed Refrigerant Cooling System
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bowden, Gordon B.; Langton, Brian J.; /SLAC
2014-05-28
The LSST Camera has a higher cryogenic heat load than previous CCD telescope cameras due to its large size (634 mm diameter focal plane, 3.2 Giga pixels) and its close coupled front-end electronics operating at low temperature inside the cryostat. Various refrigeration technologies are considered for this telescope/camera environment. MMR-Technology’s Mixed Refrigerant technology was chosen. A collaboration with that company was started in 2009. The system, based on a cluster of Joule-Thomson refrigerators running a special blend of mixed refrigerants is described. Both the advantages and problems of applying this technology to telescope camera refrigeration are discussed. Test results frommore » a prototype refrigerator running in a realistic telescope configuration are reported. Current and future stages of the development program are described. (auth)« less
Federal Register 2010, 2011, 2012, 2013, 2014
2011-09-15
...The Energy Policy and Conservation Act (EPCA) prescribes energy conservation standards for various consumer products and commercial and industrial equipment, including refrigerators, refrigerator-freezers, and freezers. EPCA also requires the U.S. Department of Energy (DOE) to determine if more stringent, amended standards for these products are technologically feasible and economically justified, and would save a significant amount of energy. In this final rule, DOE is adopting more stringent energy conservation standards for refrigerators, refrigerator-freezers, and freezers. It has determined that the amended energy conservation standards for these products would result in the significant conservation of energy and are technologically feasible and economically justified.
Birth after 12 hours of oocyte refrigeration.
Coban, Onder; Hacifazlioglu, Oguzhan; Ciray, H Nadir; Ulug, Ulun; Tekin, H Ibrahim; Bahceci, Mustafa
2010-12-01
To assess cycle outcome after oocyte refrigeration. Case report. Private IVF center. One couple in a donor oocyte program. Intracytoplasmic sperm injection and blastocyst culture after refrigeration of oocytes for 12 hours. Birth. Fourteen two-pronuclei zygotes from 17 metaphase II refrigerated oocytes resulted in transfer of two blastocysts at day 5 and cryopreservation of six excess embryos at day 6. The patient delivered one healthy male baby after 38 weeks' gestation. The successful outcome of oocyte refrigeration indicates that this protocol could be useful in circumstances in which a delay in obtaining spermatozoa arises. Copyright © 2010 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Nowak, Bernard; Życzkowski, Piotr; Łuczak, Rafał
2017-03-01
The authors of this article dealt with the issue of modeling the thermodynamic and thermokinetic properties (parameters) of refrigerants. The knowledge of these parameters is essential to design refrigeration equipment, to perform their energy efficiency analysis, or to compare the efficiency of air refrigerators using different refrigerants. One of the refrigerants used in mine air compression refrigerators is R407C. For this refrigerant, 23 dependencies were developed, determining its thermodynamic and thermokinetic parameters in the states of saturated liquid, dry saturated vapour, superheated vapor, subcooled liquid, and in the two-phase region. The created formulas have been presented in Tables 2, 5, 8, 10 and 12, respectively. It should be noted that the scope of application of these formulas is wider than the range of changes of that refrigerant during the normal operation of mine refrigeration equipment. The article ends with the statistical verification of the developed dependencies. For this purpose, for each model correlation coefficients and coefficients of determination were calculated, as well as absolute and relative deviations between the given values from the program REFPROP 7 (Lemmon et al., 2002) and the calculated ones. The results of these calculations have been contained in Tables 14 and 15.
Strategic Enterprise Resource Planning for Global Supply Chain Competitiveness
ERIC Educational Resources Information Center
Nageswararao, A. V.; Sahu, Dasarathi; Mohan, V. Krishna
2011-01-01
Strategic Enterprise Resource planning (SERP) systems are networked and integrated information mechanisms which are developed to achieve competitive advantage for organizations operating in global scale. It plays a vital role in Integrating various stake holders and channel partners involved in day to day operations. In the present Globalized…
The expanding wildland-urban interface and the proximity of prescribed fires undertaken by the Department of Defense is bringing the source of wildland fires close to densely populated areas in the Southeast. The presentation is an informational webinar to representatives of SERP...
ERIC Educational Resources Information Center
Louisiana State Dept. of Education, Baton Rouge. Div. of Vocational Education.
The curriculum guide for air conditioning/refrigeration is one of five guides written and field tested in a project to develop statewide articulated competency-based curricula in selected vocational education programs. Two separate curricula, one for the vocational-technical level and one for the associate degree level, are presented. The six…
NASA Technical Reports Server (NTRS)
Russo, S. C.
1976-01-01
A program to detect and monitor the presence of trace constituents in the earth's atmosphere by using the Limb Scanning Infrared Radiometer (LSIR) is reported. The LSIR, which makes radiometric measurements of the earth's limb radiance profile from a space platform, contains a detector assembly that must be cooled to a temperature of 65 + or - 2 K. The feasibility of cooling the NASA-type detector package with Vuilleumier (VM) cryogenic refrigerator was investigated to develop a preliminary conceptual design of a VM refrigerator that is compatible with a flight-type LSIR instrument. The scope of the LSIR program consists of analytical and design work to establish the size, weight, power consumption, interface requirements, and other important characteristics of a cryogenic cooler that would meet the requirements of the LSIR. The cryogenic cooling requirements under the conditions that NASA specified were defined. Following this, a parametric performance analysis was performed to define the interrelationships between refrigeration characteristics and mission requirements. This effort led to the selection of an optimum refrigerator design for the LSIR mission.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-09-26
... Electronics America, Inc. From the Department of Energy Residential Refrigerator and Refrigerator-Freezer Test... Electronics America, Inc. (Samsung) from energy efficiency test procedure requirements that are applicable to...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-10-19
... comments through October 18, 2010. The Air-Conditioning, Heating, and Refrigeration Institute (AHRI... refrigeration industry. Based on AHRI's request and the number of questions and issues raised during the public...
NASA Technical Reports Server (NTRS)
Miller, W. S.
1974-01-01
A structural analysis performed on the 1/4-watt cryogenic refrigerator. The analysis covered the complete assembly except for the cooling jacket and mounting brackets. Maximum stresses, margin of safety, and natural frequencies were calculated for structurally loaded refrigerator components shown in assembly drawings. The stress analysis indicates that the design is satisfactory for the specified vibration environment, and the proof, burst, and normal operating loads.
Helium refrigerator maintenance and reliability at the OPAL cold neutron source
NASA Astrophysics Data System (ADS)
Thiering, Russell; Taylor, David; Lu, Weijian
2012-06-01
Australia's first Cold Neutron Source (CNS) is a major asset to its nuclear research program. The CNS, and associated helium refrigerator, was commissioned in 2006 and is operated at the Open Pool Light Water nuclear Reactor (OPAL). The OPAL CNS operates a 20K, 5 kW Brayton cycle helium refrigerator. In this paper relevant experiences from helium refrigerator operation, maintenance and repair are presented along with the lessons learnt from a series of technical investigations. Turbine failure, due to volatile organic species, is discussed along with the related compressor oil degradation and oil separation efficiency.
40 CFR Appendix A to Subpart K of... - Criteria for evaluating a State's proposed NEPA-Like process
Code of Federal Regulations, 2014 CFR
2014-07-01
... SERP will adequately consider: (1) Designation of a study area comparable to the final system; (2) A...) Present and future conditions; (5) Land use and other social parameters including recreation and open... (residential, commercial, institutional and industrial) within the project study area; and (8) Other...
40 CFR Appendix A to Subpart K of... - Criteria for evaluating a State's proposed NEPA-Like process
Code of Federal Regulations, 2011 CFR
2011-07-01
... SERP will adequately consider: (1) Designation of a study area comparable to the final system; (2) A...) Present and future conditions; (5) Land use and other social parameters including recreation and open... (residential, commercial, institutional and industrial) within the project study area; and (8) Other...
40 CFR Appendix A to Subpart L of... - Criteria for Evaluating a State's Proposed NEPA-Like Process
Code of Federal Regulations, 2013 CFR
2013-07-01
... the SERP will adequately consider: (1) Designation of a study area comparable to the final system; (2... impacts; (4) Present and future conditions; (5) Land use and other social parameters including relevant... (residential, commercial, institutional, and industrial) within the project study area; and (8) Other...
40 CFR Appendix A to Subpart K of... - Criteria for evaluating a State's proposed NEPA-Like process
Code of Federal Regulations, 2012 CFR
2012-07-01
... SERP will adequately consider: (1) Designation of a study area comparable to the final system; (2) A...) Present and future conditions; (5) Land use and other social parameters including recreation and open... (residential, commercial, institutional and industrial) within the project study area; and (8) Other...
40 CFR Appendix A to Subpart K of... - Criteria for evaluating a State's proposed NEPA-Like process
Code of Federal Regulations, 2010 CFR
2010-07-01
... SERP will adequately consider: (1) Designation of a study area comparable to the final system; (2) A...) Present and future conditions; (5) Land use and other social parameters including recreation and open... (residential, commercial, institutional and industrial) within the project study area; and (8) Other...
40 CFR Appendix A to Subpart K of... - Criteria for evaluating a State's proposed NEPA-Like process
Code of Federal Regulations, 2013 CFR
2013-07-01
... SERP will adequately consider: (1) Designation of a study area comparable to the final system; (2) A...) Present and future conditions; (5) Land use and other social parameters including recreation and open... (residential, commercial, institutional and industrial) within the project study area; and (8) Other...
40 CFR Appendix A to Subpart L of... - Criteria for Evaluating a State's Proposed NEPA-Like Process
Code of Federal Regulations, 2014 CFR
2014-07-01
... the SERP will adequately consider: (1) Designation of a study area comparable to the final system; (2... impacts; (4) Present and future conditions; (5) Land use and other social parameters including relevant... (residential, commercial, institutional, and industrial) within the project study area; and (8) Other...
Overview of RICOR tactical cryogenic refrigerators for space missions
NASA Astrophysics Data System (ADS)
Riabzev, Sergey; Filis, Avishai; Livni, Dorit; Regev, Itai; Segal, Victor; Gover, Dan
2016-05-01
Cryogenic refrigerators represent a significant enabling technology for Earth and Space science enterprises. Many of the space instruments require cryogenic refrigeration to enable the use of advanced detectors to explore a wide range of phenomena from space. RICOR refrigerators involved in various space missions are overviewed in this paper, starting in 1994 with "Clementine" Moon mission, till the latest ExoMars mission launched in 2016. RICOR tactical rotary refrigerators have been incorporated in many space instruments, after passing qualification, life time, thermal management testing and flight acceptance. The tactical to space customization framework includes an extensive characterization and qualification test program to validate reliability, the design of thermal interfacing with a detector, vibration export control, efficient heat dissipation in a vacuum environment, robustness, mounting design, compliance with outgassing requirements and strict performance screening. Current RICOR development is focused on dedicated ultra-long-life, highly reliable, space cryogenic refrigerator based on a Pulse Tube design
Oakland and San Francisco Create Course Pathways through Common Core Mathematics. White Paper
ERIC Educational Resources Information Center
Daro, Phil
2014-01-01
The Common Core State Standards for Mathematics (CCSS-M) set rigorous standards for each of grades 6, 7 and 8. Strategic Education Research Partnership (SERP) has been working with two school districts, Oakland Unified School District and San Francisco Unified School District, to evaluate extant policies and practices and formulate new policies…
NASA Astrophysics Data System (ADS)
Ambarita, H.; Sihombing, H. V.
2018-03-01
Vapor compression cycle is mainly employed as a refrigeration cycle in the Air-Conditioning (AC) unit. In order to save energy, the Coefficient of Performance (COP) of the need to be improved. One of the potential solutions is to modify the system into multi-stages vapor compression cycle. The suitable intermediate pressure between the high and low pressures is one of the design issues. The present work deals with the investigation of an optimum intermediate pressure of two-stages vapor compression refrigeration cycle. Typical vapor compression cycle that is used in AC unit is taken into consideration. The used refrigerants are R134a. The governing equations have been developed for the systems. An inhouse program has been developed to solve the problem. COP, mass flow rate of the refrigerant and compressor power as a function of intermediate pressure are plotted. It was shown that there exists an optimum intermediate pressure for maximum COP. For refrigerant R134a, the proposed correlations need to be revised.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-03-11
... moisture. According to the petitioner, Haier's technology is similar to that used by General Electric... anti-sweat heater technology is similar to that used by General Electric, Whirlpool, Electrolux, and...) test procedure for determining the energy consumption of electric refrigerators and refrigerator...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-01-28
... procedure for determining the energy consumption of electric refrigerators and refrigerator-freezers. The... condensation. The existing test procedure does not take humidity or adaptive control technology into account. Therefore, Electrolux has suggested an alternate test procedure that takes adaptive control technology into...
USDA-ARS?s Scientific Manuscript database
The continuing attribution of human illness caused by Salmonella Enteritidis (SE) to the consumption of contaminated eggs has led to widespread implementation of risk reduction programs for commercial egg production. Prompt refrigeration of eggs to prevent bacterial multiplication to dangerously hig...
Bibliography of Training Aids. 2nd Edition.
ERIC Educational Resources Information Center
Air Conditioning and Refrigeration Inst., Arlington, VA.
A revision of ED 018 650, this annotated bibliography prepared by the Air-Conditioning and Refrigeration Institute lists training materials, films, and ancillary visual aids available from 34 member companies for use in air-conditioning and refrigeration training programs. Over 160 visual training aids are listed, arranged under the following…
Instructional Guide for Air Conditioning and Refrigeration. V & TECC Curriculum Guide.
ERIC Educational Resources Information Center
Duenk, Lester G.; And Others
This trade and industrial curriculum guide is intended for use in vocational programs that prepare students to enter the air conditioning/refrigeration field. The introductory section provides a statement of philosophy, objectives, block time schedule, and recommended facilities and equipment. Following the introductory section, eighteen blocks of…
Low Global Warming Potential Refrigerants for Commercial Refrigeration Systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fricke, Brian A.; Sharma, Vishaldeep; Abdelaziz, Omar
Supermarket refrigeration systems account for approximately 50% of supermarket energy use, placing this class of equipment among the highest energy consumers in the commercial building domain. In addition, the commonly used refrigeration system in supermarket applications is the multiplex direct expansion (DX) system, which is prone to refrigerant leaks due to its long lengths of refrigerant piping. This leakage reduces the efficiency of the system and increases the impact of the system on the environment. The high Global Warming Potential (GWP) of the hydrofluorocarbon (HFC) refrigerants commonly used in these systems, coupled with the large refrigerant charge and the highmore » refrigerant leakage rates leads to significant direct emissions of greenhouse gases into the atmosphere. Environmental concerns are driving regulations for the heating, ventilating, air-conditioning and refrigeration (HVAC&R) industry towards lower GWP alternatives to HFC refrigerants. Existing lower GWP refrigerant alternatives include hydrocarbons, such as propane (R-290) and isobutane (R-600a), as well as carbon dioxide (R-744), ammonia (R-717), and R-32. In addition, new lower GWP refrigerant alternatives are currently being developed by refrigerant manufacturers, including hydrofluoro-olefin (HFO) and unsaturated hydrochlorofluorocarbon (HCFO) refrigerants. The selection of an appropriate refrigerant for a given refrigeration application should be based on several factors, including the GWP of the refrigerant, the energy consumption of the refrigeration system over its operating lifetime, and leakage of refrigerant over the system lifetime. For example, focusing on energy efficiency alone may overlook the significant environmental impact of refrigerant leakage; while focusing on GWP alone might result in lower efficiency systems that result in higher indirect impact over the equipment lifetime. Thus, the objective of this Collaborative Research and Development Agreement (CRADA) between Honeywell and the Oak Ridge National Laboratory (ORNL) is to develop a Life Cycle Climate Performance (LCCP) modeling tool for optimally designing HVAC&R equipment with lower life cycle greenhouse gas emissions, and the selection of alternative working fluids that reduce the greenhouse gas emissions of HVAC&R equipment. In addition, an experimental evaluation program is used to measure the coefficient of performance (COP) and refrigerating capacity of various refrigerant candidates, which have differing GWP values, in commercial refrigeration equipment. Through a cooperative effort between industry and government, alternative working fluids will be chosen based on maximum reduction in greenhouse gases at minimal cost impact to the consumer. This project will ultimately result in advancing the goals of reducing greenhouse gas emissions through the use of low GWP working fluids and technologies for HVAC&R and appliance equipment, resulting in cost-competitive products and systems.« less
Recent cryocooler progress in Japan
NASA Technical Reports Server (NTRS)
Matsubara, Y.
1985-01-01
The progress of cryocoolers and related devices in Japan is reviewed. The Japanese National Railways has developed the light weight 4 K on-board refrigerators since 1977 as part of the MAGLEV train program. Superconducting and cryogenic fundamental technology was examined which included high performance cryocooler, magnetic refrigerator and superfluid refrigeration. Space cryogenics such as the cooling systems of IR-detectors was studied. Cryocooler for special applications such as cryopump, NMR-CT and JJ devices was investigated. Compact heat exchangers, high performance regenerators and reliable compressors are investigated as a critical component technology.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-02-06
... electric refrigerator and refrigerator-freezer test procedures for determining the energy consumption of... compressors using an alternate test procedure that takes this technology into account when measuring energy.... Bryan Berringer, U.S. Department of Energy, Building Technologies Program, Mailstop EE-2J, 1000...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-06-27
... electric refrigerator and refrigerator-freezer test procedures for determining the energy consumption of... using an alternate test procedure that takes this technology into account when measuring energy.... Bryan Berringer, U.S. Department of Energy, Building Technologies Program, Mail Stop EE-2J, Forrestal...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-06-27
... electric refrigerator and refrigerator-freezer test procedures for determining the energy consumption of... test procedure that takes this technology into account when measuring energy consumption. DATES: This.... Department of Energy, Building Technologies Program, Mail Stop EE-2J, Forrestal Building, 1000 Independence...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-12-16
... reasonably designed to produce test results which measure energy efficiency, energy use * * * or estimated... with at least one of the compartments designed for the refrigerated storage of food and designed to be... with at least one of the compartments designed for the freezing and storage of food at temperatures...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-05-27
...'') sets forth a variety of provisions designed to improve energy efficiency. (All references to EPCA refer... amended under this section shall be reasonably designed to produce test results which measure energy... a cabinet designed for the refrigerated storage of food at temperatures above 32 [deg]F and below 39...
State Skill Standards: Heating, Ventilation, Air Conditioning, and Refrigeration
ERIC Educational Resources Information Center
Ball, Larry; Soukup, Dennis
2006-01-01
The Department of Education has undertaken an ambitious effort to develop statewide career and technical education skill standards. The standards in this document are for Heating, Ventilation, Air Conditioning and Refrigeration (HVAC&R) programs and are designed to clearly state what the student should know and be able to do upon completion of…
The CFC challenge: chillers to replace, retrofit or ?
Anderson, W D
1995-01-01
Health care facilities are planning for changes in regulations regarding chlorofluorocarbon-based refrigerants. These changes are imminent, leaving little time to figure out what to do with equipment using these refrigerants. This article looks at the background of the CFC phaseout program and reviews options available to engineers in assessing their equipment.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-06-02
... has been adopted by AHRI--``ANSI/AHRI 1230--2010: Performance Rating of Variable Refrigerant Flow (VRF... Refrigerant Flow (VRF) Multi-Split Systems, because the basic model contains design characteristics which... line of commercial (3- phase) VRF multi-split ``AIRSTAGE V-II''. 2. The Design Characteristics FUJITSU...
Sinclair Stockpiles CFCs for Future Use.
ERIC Educational Resources Information Center
George, Stephen C.
1996-01-01
A Dayton (Ohio) community college's 21 buildings were cooled by a network of 5 chillers, all of which used soon-to-be-banned chlorofluorocarbons (CFCs). A reclamation program provides the college with reusable refrigerant and eliminates chiller replacement costs. Refrigerant from three of the old units is stockpiled for use in the two other…
77 FR 10291 - Energy Conservation Program: Test Procedure for Commercial Refrigeration Equipment
Federal Register 2010, 2011, 2012, 2013, 2014
2012-02-21
... designed for holding temperature applications, as well as self-contained refrigerators with transparent doors designed for pull-down applications. (42 U.S.C. 6313(c)(2)-(3)) EPCA also requires DOE to develop... designed for ice-cream application. 71 FR 71357 (Dec. 8, 2006). Therefore, in the December 2006 en masse...
NASA Technical Reports Server (NTRS)
1997-01-01
Through the Technology Affiliates Program at the Jet Propulsion Laboratory (JPL), valuable modifications were made to refrigerator displays built by Displaymor Manufacturing Company, Inc. By working with JPL, Displaymor could address stiffer requirements that ensure the freshness of foods. The application of the space technology meant that the small business would be able to continue to market its cases without incurring expenses that could threaten the viability of the business, and the future of several dozen jobs. Research and development improvements in air flow distribution and refrigeration coil technology contributed greatly to certifying Displaymor's showcases given the new federal regulations. These modifications resulted in a refrigerator case that will keep foods cooler, longer. Such changes maintained the openness of the display, critical to customer visibility and accessibility, impulse buying, and cross-merchandising.
Food Safety Practices Linked with Proper Refrigerator Temperatures in Retail Delis.
Brown, Laura G; Hoover, Edward Rickamer; Faw, Brenda V; Hedeen, Nicole K; Nicholas, David; Wong, Melissa R; Shepherd, Craig; Gallagher, Daniel L; Kause, Janell R
2018-05-01
Listeria monocytogenes (L. monocytogenes) causes the third highest number of foodborne illness deaths annually. L. monocytogenes contamination of sliced deli meats at the retail level is a significant contributing factor to L. monocytogenes illness. The Centers for Disease Control and Prevention's Environmental Health Specialists Network (EHS-Net) conducted a study to learn more about retail delis' practices concerning L. monocytogenes growth and cross-contamination prevention. This article presents data from this study on the frequency with which retail deli refrigerator temperatures exceed 41°F, the Food and Drug Administration (FDA)-recommended maximum temperature for ready-to-eat food requiring time and temperature control for safety (TCS) (such as retail deli meat). This provision was designed to control bacterial growth in TCS foods. This article also presents data on deli and staff characteristics related to the frequency with which retail delis refrigerator temperatures exceed 41°F. Data from observations of 445 refrigerators in 245 delis showed that in 17.1% of delis, at least one refrigerator was >41°F. We also found that refrigeration temperatures reported in this study were lower than those reported in a related 2007 study. Delis with more than one refrigerator, that lacked refrigerator temperature recording, and had a manager who had never been food safety certified had greater odds of having a refrigerator temperature >41°F. The data from this study suggest that retail temperature control is improving over time. They also identify a food safety gap: some delis have refrigerator temperatures that exceed 41°F. We also found that two food safety interventions were related to better refrigerated storage practices: kitchen manager certification and recording refrigerated storage temperatures. Regulatory food safety programs and the retail industry may wish to consider encouraging or requiring kitchen manager certification and recording refrigerated storage temperatures.
Utilizing Thermal Mass in Refrigerated Display Cases to Reduce Peak Demand
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fricke, Brian A; Kuruganti, Teja; Nutaro, James J
The potential to store energy within refrigerated food products presents convenience store and supermarket operators with an opportunity to participate in utility sponsored demand response programs, whereby electricity usage can be shifted or reduced during peak periods. To determine the feasibility of reducing peak demand by shifting the refrigeration load to off-peak times, experimental and analytical analyses were performed. Simulated product, consisting of one-pint containers filled with a 50% ethylene glycol and 50% water solution, were stored in a medium-temperature vertical open refrigerated display case. Product temperature rise as a function of time was determined by turning off the refrigerationmore » to the display case, while product temperature pull-down time was subsequently determined by turning on the refrigeration to the display case. It was found that the thermal mass of the product in a medium-temperature display case was such that during a 2.5 hour period with no refrigeration, the average product temperature increased by 5.5 C. In addition, it took approximately 3.5 hours for the product to recover to its initial temperature after the refrigeration was turned on. Transient heat conduction analyses for one-dimensional objects is in good agreement with the experimental results obtained in this study. From the analysis, it appears that the thermal mass of the stored product in refrigerated display cases is sufficient to allow product temperatures to safely drift for a significant time under reduced refrigeration system operation. Thus, strategies for shifting refrigeration system electrical demand can be developed. The use of an advanced refrigeration system controller that can respond to utility signals can enable demand shifting with minimal impact.« less
Computer program for analysis of split-Stirling-cycle cryogenic coolers
NASA Technical Reports Server (NTRS)
Brown, M. T.; Russo, S. C.
1983-01-01
A computer program for predicting the detailed thermodynamic performance of split-Stirling-cycle refrigerators has been developed. The mathematical model includes the refrigerator cold head, free-displacer/regenerator, gas transfer line, and provision for modeling a mechanical or thermal compressor. To allow for dynamic processes (such as aerodynamic friction and heat transfer) temperature, pressure, and mass flow rate are varied by sub-dividing the refrigerator into an appropriate number of fluid and structural control volumes. Of special importance to modeling of cryogenic coolers is the inclusion of real gas properties, and allowance for variation of thermo-physical properties such as thermal conductivities, specific heats and viscosities, with temperature and/or pressure. The resulting model, therefore, comprehensively simulates the split-cycle cooler both spatially and temporally by reflecting the effects of dynamic processes and real material properties.
Continuous Magnetic Refrigerators for Cooling in the 0.05 to 10 K Range
NASA Technical Reports Server (NTRS)
Shirron, Peter; DiPirro, Michael; Canavan, Edgar; Tuttle, James; Panek, John; Jackson, Michael; King, Todd; Numazawa, Takenori; Krebs, Carolyn (Technical Monitor)
2001-01-01
Low temperature refrigeration is an increasingly vital technology for NASA's Space Science program since most detectors being developed for x-ray, IR and sub-millimeter missions must be cooled to below 100 mK in order to meet the requirements for energy and spatial resolution. For space applications, magnetic refrigeration has an inherent advantage over alternative techniques because it does not depend on gravity. Adiabatic demagnetization refrigerators, or ADRs, are relatively simple, solid state devices. The basic elements are a magnetocaloric refrigerant (usually an encapsulated paramagnetic salt) located in the bore of a superconducting magnet, and a heat switch linking the salt to a heat sink. The alignment of magnetic spins with the magnetic field causes the refrigerant to warm as the magnetic field increases and cool as the field decreases. Thus the simple process of magnetizing the refrigerant to high field with the heat switch closed, then demagnetizing it with the heat switch open allows one to obtain temperatures well below 100 mK using a heat sink as warm as 4.2 K. The refrigerant can maintain a low temperature for a length of time depending on the applied and parasitic heat loads, its mass, and the initial magnetic field strength. Typically ADRs are designed for 12-24 hours of hold time, after which they must be warmed up and recycled.
ERIC Educational Resources Information Center
Ohio State Univ., Columbus. National Center for Research in Vocational Education.
This plan of instruction, study guides, workbooks, and programmed texts for a secondary-postsecondary-level course in refrigeration and air conditioning are one of a number of military-developed curriculum packages selected for adaptation to vocational instruction and curriculum development in a civilian setting. It is the first section of a…
Code of Federal Regulations, 2014 CFR
2014-07-01
..., Recycling and/or Reclaim Equipment B1 Appendix B1 to Subpart F of Part 82 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) PROTECTION OF STRATOSPHERIC OZONE Recycling... Refrigerant Recovery, Recycling and/or Reclaim Equipment This appendix is based on the Air-Conditioning and...
Code of Federal Regulations, 2013 CFR
2013-07-01
..., Recycling and/or Reclaim Equipment B1 Appendix B1 to Subpart F of Part 82 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) PROTECTION OF STRATOSPHERIC OZONE Recycling... Refrigerant Recovery, Recycling and/or Reclaim Equipment This appendix is based on the Air-Conditioning and...
Code of Federal Regulations, 2012 CFR
2012-07-01
..., Recycling and/or Reclaim Equipment B1 Appendix B1 to Subpart F of Part 82 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) PROTECTION OF STRATOSPHERIC OZONE Recycling... Refrigerant Recovery, Recycling and/or Reclaim Equipment This appendix is based on the Air-Conditioning and...
Supermarket refrigeration assessment for the Commonwealth Electric Company
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tsaros, T.L.; Walker, D.H.
The Commonwealth Electric Company (COM/Electric) has initiated an incentive program to promote electric energy conservation within its service territory. The Electric Power Research Institute (EPRI) has assisted COM/Electric in assessing the impact on the utility and its customers of implementing energy efficient supermarket refrigeration in retrofit applications. The primary task of this assessment was to contact the supermarket chains and refrigeration contractors and suppliers in the COM/Electric service territory to determine the type of refrigeration employed and standard or novel retrofit equipment implemented in supermarkets. With this information, estimates were made of the potential energy savings that COM/Electric and themore » supermarkets could realize if supermarkets were retrofitted with energy efficient refrigeration equipment. It was determined that the refrigerated display case features offering the greatest potential for savings through retrofit installations include doors for medium temperature multideck cases, high-efficiency fan motors, anti-sweat heater controls, and vinyl strip curtains for walk-in coolers. The retrofit components associated with the compressor machine room that offer the greatest potential for savings include the use of low heat pressure control, hot gas defrost, and external liquid-suction heat exchangers and remote evaporative subcoolers for low temperature refrigeration. 6 refs., 14 figs., 26 tabs.« less
Federal Register 2010, 2011, 2012, 2013, 2014
2013-09-11
...The Energy Policy and Conservation Act of 1975 (EPCA), as amended, prescribes energy conservation standards for various consumer products and certain commercial and industrial equipment, including commercial refrigeration equipment (CRE). EPCA also requires the U.S. Department of Energy (DOE) to determine whether more-stringent, amended standards would be technologically feasible and economically justified, and would save a significant amount of energy. In this notice, DOE proposes amended energy conservation standards for commercial refrigeration equipment. The notice also announces a public meeting to receive comment on these proposed standards and associated analyses and results.
2008-09-01
TWO-PHASE FLOW IN HIGH-HEAT-FLUX MICRO-CHANNEL HEAT SINK FOR REFRIGERATION COOLING APPLICATIONS (Contract No. N00014-05-1-0408) by Issam Mudawar ...Refrigeration Cooling Applications 5b. GRANT NUMBER N00014-04-1-0408 5c. PROGRAM ELEMENT NUMBER NA 6. AUTHOR(S) 5d. PROJECT NUMBER Mudawar , Issam NA...ABSTRACT OF Mudawar , Issam PAGES U U U UU 465 19b. TELEPHONE NUMBER (Include area code) 765-494-5705 Standard Form 298 (Rev. 8/98) Prescribed by ANSI Std
Analysis of a combined refrigerator-generator space power system
NASA Technical Reports Server (NTRS)
Klann, J. L.
1973-01-01
Description of a single-shaft and a two-shaft rotating machinery arrangements using neon for application in a combined refrigerator-generator power system for space missions. The arrangements consist of combined assemblies of a power turbine, alternator, compressor, and cry-turbine with a single-stage radial-flow design. A computer program was prepared to study the thermodynamics of the dual system in the evaluation of its cryocooling/electric capacity and appropriate weight. A preliminary analysis showed that a two-shaft arrangement of the power- and refrigeration-loop rotating machinery provided better output capacities than a single-shaft arrangement, without prohibitive operating compromises.
Alternative refrigerants and refrigeration cycles for domestic refrigerators
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sand, J.R.; Rice, C.L.; Vineyard, E.A.
1992-12-01
This project initially focused on using nonazeotropic refrigerant mixtures (NARMs) in a two-evaporator refrigerator-freezer design using two stages of liquid refrigerant subcooling. This concept was proposed and tested in 1975. The work suggested that the concept was 20% more efficient than the conventional one-evaporator refrigerator-freezer (RF) design. After considerable planning and system modeling based on using a NARM in a Lorenz-Meutzner (L-M) RF, the program scope was broadened to include investigation of a ``dual-loop`` concept where energy savings result from exploiting the less stringent operating conditions needed to satisfy cooling, of the fresh food section. A steady-state computer model (CYCLE-Z)more » capable of simulating conventional, dual loop, and L-M refrigeration cycles was developed. This model was used to rank the performance of 20 ozone-safe NARMs in the L-M refrigeration cycle while key system parameters were systematically varied. The results indicated that the steady-state efficiency of the L-M design was up to 25% greater than that of a conventional cycle. This model was also used to calculate the performance of other pure refrigerants relative to that of dichlorodifluoromethane, R-12, in conventional and dual-loop RF designs. Projected efficiency gains for these cycles were more modest, ranging from 0 to 10%. Individual compressor calorimeter tests of nine combinations of evaporator and condenser temperatures usually used to map RF compressor performance were carried out with R-12 and two candidate L-M NARMs in several compressors. Several models of a commercially produced two-evaporator RF were obtained as test units. Two dual-loop RF designs were built and tested as part of this project.« less
RAD partner programs help protect the ozone layer and reduce emissions of greenhouse gases by disposing of older, inefficient refrigerated appliances using the best environmental practices and technologies available.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shah, Nihar; Wei, Max; Letschert, Virginie
2015-10-01
Hydrofluorocarbons (HFCs) emitted from uses such as refrigerants and thermal insulating foam, are now the fastest growing greenhouse gases (GHGs), with global warming potentials (GWP) thousands of times higher than carbon dioxide (CO2). Because of the short lifetime of these molecules in the atmosphere, mitigating the amount of these short-lived climate pollutants (SLCPs) provides a faster path to climate change mitigation than control of CO2 alone. This has led to proposals from Africa, Europe, India, Island States, and North America to amend the Montreal Protocol on Substances that Deplete the Ozone Layer (Montreal Protocol) to phase-down high-GWP HFCs. Simultaneously, energymore » efficiency market transformation programs such as standards, labeling and incentive programs are endeavoring to improve the energy efficiency for refrigeration and air conditioning equipment to provide life cycle cost, energy, GHG, and peak load savings. In this paper we provide an estimate of the magnitude of such GHG and peak electric load savings potential, for room air conditioning, if the refrigerant transition and energy efficiency improvement policies are implemented either separately or in parallel. We find that implementing HFC refrigerant transition and energy efficiency improvement policies in parallel for room air conditioning, roughly doubles the benefit of either policy implemented separately. We estimate that shifting the 2030 world stock of room air conditioners from the low efficiency technology using high-GWP refrigerants to higher efficiency technology and low-GWP refrigerants in parallel would save between 340-790 gigawatts (GW) of peak load globally, which is roughly equivalent to avoiding 680-1550 peak power plants of 500MW each. This would save 0.85 GT/year annually in China equivalent to over 8 Three Gorges dams and over 0.32 GT/year annually in India equivalent to roughly twice India’s 100GW solar mission target. While there is some uncertainty associated with emissions and growth projections, moving to efficient room air conditioning (~30% more efficient than current technology) in parallel with low-GWP refrigerants in room air conditioning could avoid up to ~25 billion tonnes of CO2 in 2030, ~33 billion in 2040, and ~40 billion in 2050, i.e. cumulative savings up to 98 billion tonnes of CO2 by 2050. Therefore, superefficient room ACs using low-GWP refrigerants merit serious consideration to maximize peak load reduction and GHG savings.« less
An efficient planar accordion-shaped micromixer: from biochemical mixing to biological application
Cosentino, Armando; Madadi, Hojjat; Vergara, Paola; Vecchione, Raffaele; Causa, Filippo; Netti, Paolo Antonio
2015-01-01
Micromixers are the key component that allow lab-on-a-chip and micro total analysis systems to reach the correct level of mixing for any given process. This paper proposes a novel, simple, passive micromixer design characterized by a planar accordion-shape geometry. The geometrical characteristics of the presented design were analyzed numerically in the range of 0.01 < Re < 100 based on the micromixer performance. The performance of the most efficient design was experimentally investigated by means of fluorescence microscopy for a range of low diffusion coefficients, 10−12 < D < 10−11 m2/s. The micromixer structure was fabricated in a simple single-step process using maskless lithography and soft lithography. The experimental results showed a very good agreement with the predicted numerical results. This micromixer design including a single serpentine unit (1-SERP) displayed an efficiency higher than 90% (mixing length = 6.4 mm) creating a pressure drop of about 500 Pa at Re = 0.1 and 60 kPa at Re = 10. A mixing efficiency of almost 100% was readily reached when three serpentine units were included (3-SERP). Finally, the potential diagnostic value of the presented microdevice was validated experimentally for Red Blood Cell (RBC) lysis. PMID:26658848
An efficient planar accordion-shaped micromixer: from biochemical mixing to biological application
NASA Astrophysics Data System (ADS)
Cosentino, Armando; Madadi, Hojjat; Vergara, Paola; Vecchione, Raffaele; Causa, Filippo; Netti, Paolo Antonio
2015-12-01
Micromixers are the key component that allow lab-on-a-chip and micro total analysis systems to reach the correct level of mixing for any given process. This paper proposes a novel, simple, passive micromixer design characterized by a planar accordion-shape geometry. The geometrical characteristics of the presented design were analyzed numerically in the range of 0.01 < Re < 100 based on the micromixer performance. The performance of the most efficient design was experimentally investigated by means of fluorescence microscopy for a range of low diffusion coefficients, 10-12 < D < 10-11 m2/s. The micromixer structure was fabricated in a simple single-step process using maskless lithography and soft lithography. The experimental results showed a very good agreement with the predicted numerical results. This micromixer design including a single serpentine unit (1-SERP) displayed an efficiency higher than 90% (mixing length = 6.4 mm) creating a pressure drop of about 500 Pa at Re = 0.1 and 60 kPa at Re = 10. A mixing efficiency of almost 100% was readily reached when three serpentine units were included (3-SERP). Finally, the potential diagnostic value of the presented microdevice was validated experimentally for Red Blood Cell (RBC) lysis.
An efficient planar accordion-shaped micromixer: from biochemical mixing to biological application.
Cosentino, Armando; Madadi, Hojjat; Vergara, Paola; Vecchione, Raffaele; Causa, Filippo; Netti, Paolo Antonio
2015-12-14
Micromixers are the key component that allow lab-on-a-chip and micro total analysis systems to reach the correct level of mixing for any given process. This paper proposes a novel, simple, passive micromixer design characterized by a planar accordion-shape geometry. The geometrical characteristics of the presented design were analyzed numerically in the range of 0.01 < Re < 100 based on the micromixer performance. The performance of the most efficient design was experimentally investigated by means of fluorescence microscopy for a range of low diffusion coefficients, 10(-12) < D < 10(-11) m(2)/s. The micromixer structure was fabricated in a simple single-step process using maskless lithography and soft lithography. The experimental results showed a very good agreement with the predicted numerical results. This micromixer design including a single serpentine unit (1-SERP) displayed an efficiency higher than 90% (mixing length = 6.4 mm) creating a pressure drop of about 500 Pa at Re = 0.1 and 60 kPa at Re = 10. A mixing efficiency of almost 100% was readily reached when three serpentine units were included (3-SERP). Finally, the potential diagnostic value of the presented microdevice was validated experimentally for Red Blood Cell (RBC) lysis.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gunsel, Selda; Pozebanchuk, Michael
1999-04-01
Lubrication properties of refrigeration lubricants were investigated in high pressure nonconforming contacts under different conditions of temperature, rolling speed, and refrigerant concentration. The program was based upon the recognition that the lubrication regime in refrigeration compressors is generally elastohydrodynamic or hydrodynamic, as determined by the operating conditions of the compressor and the properties of the lubricant. Depending on the compressor design, elastohydrodynamic lubrication conditions exist in many rolling and sliding elements of refrigeration compressors such as roller element bearings, gears, and rotors. The formation of an elastohydrodynamic film separating rubbing surfaces is important in preventing the wear and failure ofmore » compressor elements. It is, therefore, important to predict the elastohydrodynamic (EHD) performance of lubricants under realistic tribocontact renditions. This is, however, difficult as the lubricant properties that control film formation are critically dependent upon pressure and shear, and cannot be evaluated using conventional laboratory instruments. In this study, the elastohydrodynamic behavior of refrigeration lubricants with and without the presence of refrigerants was investigated using the ultrathin film EHD interferometry technique. This technique enables very thin films, down to less than 5 nm, to be measured accurately within an EHD contact under realistic conditions of temperature, shear, and pressure. The technique was adapted to the study of lubricant refrigerant mixtures. Film thickness measurements were obtained on refrigeration lubricants as a function of speed, temperature, and refrigerant concentration. The effects of lubricant viscosity, temperature, rolling speed, and refrigerant concentration on EHD film formation were investigated. From the film thickness measurements, effective pressure-viscosity coefficients were calculated. The lubricants studied in this project included two naphthenic mineral oils (NMO), four polyolesters (POE), and two polyvinyl ether (PVE) fluids. These fluids represented viscosity grades of ISO 32 and ISO 68 and are shown in a table. Refrigerants studied included R-22, R-134a, and R-410A. Film thickness measurements were conducted at 23 C, 45 C, and 65 C with refrigerant concentrations ranging from zero to 60% by weight.« less
ERIC Educational Resources Information Center
Henderson, William Edward, Jr., Ed.
This articulation guide contains 17 units of instruction for the second year of a two-year vocational program designed to prepare the high school graduate to install, maintain, and repair various types of residential and commercial heating, air conditioning, and refrigeration equipment. The units are designed to help the student to expand and…
ERIC Educational Resources Information Center
Missouri Univ., Columbia. Instructional Materials Lab.
This index was developed to help air conditioning and refrigeration instructors in Missouri use existing instructional materials and keep track of student progress on the VAMS system. The list was compiled by a committee of instructors who selected appropriate references and identified areas that pertained to Missouri competencies. The index lists…
ERIC Educational Resources Information Center
Henderson, William Edward, Jr., Ed.
This articulation guide contains 17 units of instruction for the first year of a two-year vocational program designed to prepare the high school graduate to install, maintain, and repair various types of residential and commercial heating, air conditioning, and refrigeration equipment. The units are to introduce the student to fundamental theories…
Guidance for Facilities on Risk Management Programs (RMP)
Includes supplemental guidance specific to ammonia refrigeration, wastewater treatment, propane storage, warehouses, chemical distributors, offsite consequence analysis, retail agriculture, applicability of program levels, prevention, emergency response.
McCarney, Steve; Robertson, Joanie; Arnaud, Juliette; Lorenson, Kristina; Lloyd, John
2013-12-09
Large areas of many developing countries have no grid electricity. This is a serious challenge that threatens the continuity of the vaccine cold chain. The main alternatives to electrically powered refrigerators available for many years--kerosene- and gas-driven refrigerators--are plagued by problems with gas supply interruptions, low efficiency, poor temperature control, and frequent maintenance needs. There are currently no kerosene- or gas-driven refrigerators that qualify under the minimum standards established by the World Health Organization (WHO) Performance, Quality, and Safety (PQS) system. Solar refrigeration was a promising development in the early 1980s, providing an alternative to absorption technology to meet cold chain needs in remote areas. Devices generally had strong laboratory performance data; however, experience in the field over the years has been mixed. Traditional solar refrigerators relied on relatively expensive battery systems, which have demonstrated short lives compared to the refrigerator. There are now alternatives to the battery-based systems and a clear understanding that solar refrigerator systems need to be designed, installed, and maintained by technicians with the necessary knowledge and training. Thus, the technology is now poised to be the refrigeration method of choice for the cold chain in areas with no electricity or extremely unreliable electricity (less than 4h per average day) and sufficient sunlight. This paper highlights some lessons learned with solar-powered refrigeration, and discusses some critical factors for successful introduction of solar units into immunization programs in the future including: •Sustainable financing mechanisms and incentives for health workers and technicians are in place to support long-term maintenance, repair, and replacement parts. •System design is carried out by qualified solar refrigerator professionals taking into account the conditions at installation sites. •Installation and repair are conducted by well-trained technicians. •Temperature performance is continuously monitored and protocols are in place to act on data that indicate problems. Copyright © 2013 The Authors. Published by Elsevier Ltd.. All rights reserved.
Estimates of Refrigerator Loads in Public Housing Based on Metered Consumption Data
DOE Office of Scientific and Technical Information (OSTI.GOV)
Miller, JD; Pratt, RG
1998-09-11
The New York Power Authority (NYPA), the New York City Housing Authority (NYCHA), and the U.S. Departments of Housing and Urban Development (HUD) and Energy (DOE) have joined in a project to replace refrigerators in New York City public housing with new, highly energy-efficient models. This project laid the ground work for the Consortium for Energy Efficiency (CEE) and DOE to enable housing authorities throughout the United States to bulk-purchase energy-efficient appliances. DOE helped develop and plan the program through the ENERGY STAR@ Partnerships program conducted by its Pacific Nofiwest National Laboratory (PNNL). PNNL was subsequently asked to conduct themore » savings evahations for 1996 and 1997. PNNL designed the metering protocol and occupant survey, supplied and calibrated the metering equipment, and managed and analyzed the data. The 1996 metering study of refrigerator energy usage in New York City public housing (Pratt and Miller 1997) established the need and justification for a regression-model-based approach to an energy savings estimate. The need originated in logistical difficulties associated with sampling the population and pen?orming a stratified analysis. Commonly, refrigerators[a) with high representation in the population were missed in the sampling schedule, leaving significant holes in the sample and difficulties for the stratified anrdysis. The just{jfcation was found in the fact that strata (distinct groups of identical refrigerators) were not statistically distinct in terms of their label ratio (ratio of metered consumption to label rating). This finding suggested a general regression model could be used to represent the consumption of all refrigerators in the population. In 1996 a simple two-coefficient regression model, a function of only the refrigerator label rating, was developed and used to represent the existing population of refrigerators. A key concept used in the 1997 study grew from findings in a small number of apartments metered in 1996 with a detailed protocol. Fifteen-minute time-series data of ambient and compartment temperatures and refrigerator power were analyzed and demonstrated the potential for reducing power records into three components. This motivated the development of an analysis process to divide the metered consumption into baseline load, occupant-associated load, and defrosting load. The baseline load is the consumption that would occur if the refrigerator were on but had no occupant usage load (no door-opening events) and the defrosting mechanism was disabled. The motivation behind this component reduction process was the hope that components could be more effectively modeled than the total. We reasoned that the components would lead to abetter (more general and more significant) understanding of the relationships between consumption, the characteristics of the refrigerator, and its operating environment.« less
Transient Analysis of a Magnetic Heat Pump
NASA Technical Reports Server (NTRS)
Schroeder, E. A.
1985-01-01
An experimental heat pump that uses a rare earth element as the refrigerant is modeled using NASTRAN. The refrigerant is a ferromagnetic metal whose temperature rises when a magnetic field is applied and falls when the magnetic field is removed. The heat pump is used as a refrigerator to remove heat from a reservoir and discharge it through a heat exchanger. In the NASTRAN model the components modeled are represented by one-dimensional ROD elements. Heat flow in the solids and fluid are analyzed. The problem is mildly nonlinear since the heat capacity of the refrigerant is temperature-dependent. One simulation run consists of a series of transient analyses, each representing one stroke of the heat pump. An auxiliary program was written that uses the results of one NASTRAN analysis to generate data for the next NASTRAN analysis.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Biancardi, F.R.; Michels, H.; Sienel, T.
1996-01-01
As a means of complying with current and impending national and international environmental regulations restricting the use and disposal of conventional CFC and HCFC refrigerants which contribute to the global ozone depletion effects, the HVAC industry is vigorously evaluating and testing BFC refrigerant blends. While analyses and system performance tools have shown that BFC refrigerant blends offer certain performance, capacity and operational advantages, there are significant possible service and operational issues that are raised by the use of blends. Many of these issues occur due to the fractionation of the blends. Therefore, the objective of this program is to conductmore » analyses and experimental tests aimed at understanding these issues, develop approaches or techniques to predict these effects and convey to the industry safe and reliable approaches. As a result, analytical models, verified by laboratory data, have been developed that predict the fractionation effects of HFC refrigerant blends when (1) exposed to selected POE lubricants, (2) during the system charging process from large liquid containers, and (3) during system startup, operation and shutdown within various system components (where two-phase refrigerant exists), and during selected system and component leakage scenarios. Model predictions and experimental results are presented for HFC refrigerant blends containing HFC-32, HFC-134a, and HFC-125 and the data are generalized for various operating conditions and scenarios.« less
NASA Technical Reports Server (NTRS)
Shirron, Peter; DiPirro, Michael; Canavan, Edgar; Tuttle, James; King, Todd; Numazawa, Takenori
2003-01-01
Low temperature refrigeration is an increasingly vital technology for NASA s Space Science program since most detectors being developed for x-ray, IR and sub-millimeter missions must be cooled to below 100 mK in order to meet the requirements for energy and spatial resolution. For space applications, magnetic refrigeration has an inherent advantage over alternative techniques because it does not depend on gravity. Adiabatic demagnetization refrigerators, or ADRs, are relatively simple, solid state devices. The basic elements are a magnetocaloric refrigerant (usually an encapsulated paramagnetic salt) located in the bore of a superconducting magne$, and a heat switch linking the salt to a heat sink. The alignment of magnetic spins with the magnetic field causes the refrigerant to warm as the magnetic field increases and cool as the field decreases. Thus the simple process of magnetizing the refrigerant to high field with the heat switch closed, then demagnetizing it with the heat switch open allows one to obtain temperatures well below 100 mK using a heat sink as warm as 4.2 K. The refrigerant can maintain a low temperature for a length of time depending on the applied and parasitic heat loads, its mass, and the initial magnetic field strength. Typically ADRs are designed for 12-24 hours of hold time, after which they must be warmed up and recycled. The drawback to single-shot ADRs is that the cooling power per unit mass is relatively low. Refrigerants that are suitable for low temperature operation necessarily have low magnetic ion density, and therefore low entropy density. Since ADRs store entropy, systems with even modest cooling powers (a few microwatts) at temperatures below 100 mK tend to be massive, averaging 10-15 kg.
Development and performance evaluation of high speed cryogenic turboexpanders at BARC, India
NASA Astrophysics Data System (ADS)
Chakravarty, A.; Menon, R. S.; Goyal, M.; Ahmed, N.; Jadhav, M.; Rane, T.; Nair, S. R.; Kumar, J.; Kumar, N.; Bharti, S. K.; Jain, A.; Joemon, V.
2017-12-01
Turboexpanders are a key focus area for Bhabha Atomic Research Centre (BARC), Mumbai, India in the program for development of helium refrigerators and liquefiers for intra departmental requirements. To start with, a turbine impeller with major diameter 16 mm and design speed of 264,000 RPM, suited for use in the 1st stage of a modified Claude cycle/reverse Brayton cycle based standard helium liquefier/refrigerator, is developed. Later on, a second series of turboexpander with the same major diameter (16 mm) and design speed of 260,000 RPM is developed with “splitter” blades at the major diameter end. Yet another turboexpander series, size 16.5 mm and design speed 168,000 RPM, is also developed suited for use in the 2nd stage of a standard helium liquefier/refrigerator. The present article describes these turboexpander development efforts at BARC, including results obtained during field trials with the BARC helium refrigerator and liquefier.
Dynamic Characteristics of a Simple Brayton Cryocycle
NASA Astrophysics Data System (ADS)
Kutzschbach, A.; Kauschke, M.; Haberstroh, Ch.; Quack, H.
2006-04-01
The goal of the overall program is to develop a dynamic numerical model of helium refrigerators and the associated cooling systems based on commercial simulation software. The aim is to give system designers a tool to search for optimum control strategies during the construction phase of the refrigerator with the help of a plant "simulator". In a first step, a simple Brayton refrigerator has been investigated, which consists of a compressor, an after-cooler, a counter-current heat exchanger, a turboexpander and a heat source. Operating modes are "refrigeration" and "liquefaction". Whereas for the steady state design only component efficiencies are needed and mass and energy balances have to be calculated, for the dynamic calculation one needs also the thermal masses and the helium inventory. Transient mass and energy balances have to be formulated for many small elements and then solved simultaneously for all elements. Starting point of the simulation of the Brayton cycle is the steady state operation at design conditions. The response of the system to step and cyclic changes of the refrigeration or liquefaction rate are calculated and characterized.
Study of lubricant circulation in HVAC systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Biancardi, F.; Sienel, T.; Pandy, D.
1997-02-01
This program was aimed at understanding refrigerant/lubricant circulation issues, developing test data and approximate models that can predict operating regimes where good oil management can be assured. A dynamic test facility was constructed and used to examine oil return under varying system operating conditions. The development of industry guidelines for system reliability in using the new refrigerant blends was a goal of this program. To validate the guidelines, techniques and predictions, this dynamic test facility was used to obtain data to compare to the analytical predictions. The overall program approach undertaken to meet this objective was: (1) to identify poormore » oil return scenarios and, therefore, the worst case oil return parameters for conventional residential HVAC systems using HCFC-22 and mineral oils, in terms of compressor, suction and exhaust line vapor velocity, and refrigerant viscosity requirements; (2) design and instrument a test apparatus that simulates such conditions, as well as those that might be achieved with HFC and POE mixtures and HFCs and mineral oils; (3) conduct tests with the range of baseline refrigerants and lubricant mixtures to provide experimental data; and (4) prepare, present and interpret the test data to provide an expanded understanding of the phenomena required for good oil circulation in split-system heat pump systems. To convert this general approach into the program specifics, three major tasks were defined and pursued. These are described briefly here and in greater detail in the report body as Task 1, Task 2, and Task 3. The report prepared for ARTI as part of the MCLR Project Number 665-53100 is described in Volumes 1 and 2, ``Study of Lubricant Circulation in the HVAC Systems,`` October 1996, from the same authors as this publication. This record consists of the overheads used in the presentation.« less
10th Anniversary of the Responsible Appliance Disposal Program Report
The RAD program recognizes partners that commit to collecting and disposing of old refrigerated appliances using the best environmental practices available and going beyond what is requiredby federal law.
The Rebirth of a Career and Technical Education Program.
ERIC Educational Resources Information Center
Reese, Susan
2003-01-01
Describes how a Milwaukee high school sustained its career and technical education programs by cultivating business-industry partnerships and developing a successful heating, ventilation, air conditioning, and refrigeration curriculum. (JOW)
Design of Standards and Labeling programs in Chile: Techno-Economic Analysis for Refrigerators
DOE Office of Scientific and Technical Information (OSTI.GOV)
Letschert, Virginie E.; McNeil, Michael A.; Pavon, Mariana
2013-05-01
Lawrence Berkeley National Laboratory is a global leader in the study of energy efficiency and its effective implementation through government policy. The Energy Analysis and Environmental Impacts Department of LBNL’s Environmental Energy Technologies Division provides technical assistance to help federal, stat e and local government agencies in the United States, and throughout the world, develop long-term strategies, policy, and programs to encourage energy efficiency in all sectors and industries. In the past, LBNL has assisted staff of various countries government agencies and their con tractors in providing methodologies to analyze cost-effectiveness of regulations and asses s overall national impacts ofmore » efficiency programs. The paper presents the work done in collaboration with the Ministry of Energy (MoE) in Chile and the Collaborative Labeling Appliance Standards Programs (CLASP) on designing a Minimum Energy Performance Standards (MEPS) and ext ending the current labeling program for refrigerators.« less
2013-05-22
responsible for conducting Reception , Staging, Onward movement, and Integration of personnel and equipment, the distribution management of supplies...temperature refrigerated containers or leased refrigerated containers on semi- trailers . Class III Distribution As the DoD executive agent, DLA is...quantitative approach involves the investigation of a human or social problem, and tests the theory based on the collection of variables, numerically
De Pascalis, Vilfredo; Varriale, Vincenzo; Cacace, Immacolata
2015-01-01
Using a strict subject selection procedure, we tested in High and Low Hypnotizable subjects (HHs and LHs) whether treatments of hypoalgesia and hyperalgesia, as compared to a relaxation-control, differentially affected subjective pain ratings and somatosensory event-related potentials (SERPs) during painful electric stimulation. Treatments were administered in waking and hypnosis conditions. LHs showed little differentiation in pain and distress ratings between hypoalgesia and hyperalgesia treatments, whereas HHs showed a greater spread in the instructed direction. HHs had larger prefrontal N140 and P200 waves of the SERPs during hypnotic hyperalgesia as compared to relaxation-control treatment. Importantly, HHs showed significant smaller frontocentral N140 and frontotemporal P200 waves during hypnotic hypoalgesia. LHs did not show significant differences for these SERP waves among treatments in both waking and hypnosis conditions. Source localization (sLORETA) method revealed significant activations of the bilateral primary somatosensory (BA3), middle frontal gyrus (BA6) and anterior cingulate cortices (BA24). Activity of these contralateral regions significantly correlated with subjective numerical pain scores for control treatment in waking condition. Moreover, multivariate regression analyses distinguished the contralateral BA3 as the only region reflecting a stable pattern of pain coding changes across all treatments in waking and hypnosis conditions. More direct testing showed that hypnosis reduced the strength of the association of pain modulation and brain activity changes at BA3. sLORETA in HHs revealed, for the N140 wave, that during hypnotic hyperalgesia, there was an increased activity within medial, supramarginal and superior frontal gyri, and cingulated gyrus (BA32), while for the P200 wave, activity was increased in the superior (BA22), middle (BA37), inferior temporal (BA19) gyri and superior parietal lobule (BA7). Hypnotic hypoalgesia in HHs, for N140 wave, showed reduced activity within medial and superior frontal gyri (BA9,8), paraippocampal gyrus (BA34), and postcentral gyrus (BA1), while for the P200, activity was reduced within middle and superior frontal gyri (BA9 and BA10), anterior cingulate (BA33), cuneus (BA19) and sub-lobar insula (BA13). These findings demonstrate that hypnotic suggestions can exert a top-down modulatory effect on attention/preconscious brain processes involved in pain perception. PMID:26030417
NASA Astrophysics Data System (ADS)
Kauffeld, Michael; Mulroy, William; McLinden, Mark; Didion, David
1990-02-01
As part of the Department of Energy/Oak Ridge National Laboratory Building Equipment Research program, the National Institute of Standards and Technology constructed an experimental, easily reconfigurable, water-to-water, breadboard heat pump apparatus in order to compare pure R22 to nonazeotropic refrigerant mixtures. Performance of the heat pump charged with a range of compositions of the binary mixtures R22/RI14 and R13/R12 were compared to R22. The advantage claimed for mixtures in this application is improved thermodynamic efficiency as a result of gliding refrigerant temperatures in the evaporator and condenser in low lift, high glide applications typical of air conditioning.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Biancardi, F.R.; Pandy, D.R.; Sienel, T.H.
1997-12-31
The heating, ventilating, and air-conditioning (HVAC) industry is actively evaluating and testing hydrofluorocarbon (HFC) refrigerant blends as a means of complying with current and impending national and international environmental regulations restricting the use and disposal of conventional chlorofluorocarbon (CFC) and hydrochlorofluorocarbon (HCFC) refrigerants that contribute to the global ozone-depletion effects. While analyses and system performance tools have shown that HFC refrigerant blends offer certain performance, capacity, and operational advantages, there are significant possible service and operational issues that are raised by the use of blends. Many of these issues occur due to the fractionation of the blends. Therefore, the objectivemore » of this program was to conduct analyses and experimental tests aimed at understanding these issues, develop approaches or techniques to predict these effects, and convey to the industry safe and reliable approaches. As a result, analytical models verified by laboratory data have been developed that predict the fractionation effects of HFC refrigerant blends (1) when exposed to selected POE lubricants, (2) during the system charging process from large liquid containers, and (3) during system start-up, operation, and shutdown within various system components (where two-phase refrigerant exists) and during selected system and component leakage scenarios. Model predictions and experimental results are presented for HFC refrigerant blends containing R-32, R-134a, and R-125 and the data are generalized for various operating conditions and scenarios.« less
Thielmann, Anika; Viehmann, Anja; Weltermann, Birgitta M
2015-07-14
Immunization programs are among the most effective public health strategies worldwide. Adequate vaccine storage is a prerequisite to assure the vaccines' effectiveness and safety. In a questionnaire survey among a random sample of German primary care physicians, we discovered vaccine storage deficits: 16% of physicians had experience with cold chain breaches either as an error or near error, 49 % did not keep a temperature log, and 21 % did not use a separate refrigerator for vaccine storage. In a recent feasibility study of 21 practice refrigerators, we showed that these were outside the target range 10.2% of the total time with some single refrigerators being outside the target range as much as 66.3% of the time. These cooling-chain deficits are consistent with the international medical literature, yet an effective, easy to disseminate, practice-centered intervention to improve storage conditions is lacking. This randomized intervention trial will be conducted in a random sample of primary care practices. Based on continuous temperature recordings over 7 days, all practices with readings outside the target range for vaccine storage (+2 °C to +8 °C) will be randomly allocated to a web-based education program or a waiting list control group. The practice physicians and their teams constitute the target population. Participants will be educated about best practices in vaccine storage and will receive a manual including storage checklists and templates for temperature documentation. In all practices, temperatures of the vaccine refrigerators will be monitored continuously using a data logger with a glycol probe as a surrogate for vaccine vial temperature. The effectiveness of the web-based education program will be determined after 6 months in terms of the proportion of refrigerators with vaccine vial temperatures within the target range (+2 °C to +8 °C) during 7-day temperature logging. Secondary outcome parameters include temperature monitoring, no critically low temperatures (≤ -0.5 °C), compliance with storage recommendations, knowledge of good vaccine storage conditions, and assignment of personnel as vaccine storage manager and backup. Keep Cool will develop and evaluate a web-based education program to improve vaccine storage conditions in primary care and thereby ensure immunization safety and effectiveness. DRKS00006561 (date of registration: 20 February 2015).
DOE Office of Scientific and Technical Information (OSTI.GOV)
McNeil, Michael A.; Iyer, Maithili
The development of Energy Efficiency Standards and Labeling (EES&L) began in earnest in India in 2001 with the Energy Conservation Act and the establishment of the Indian Bureau of Energy Efficiency (BEE). The first main residential appliance to be targeted was refrigerators, soon to be followed by room air conditioners. Both of these appliances are of critical importance to India's residential electricity demand. About 15percent of Indian households own a refrigerator, and sales total about 4 million per year, but are growing. At the same time, the Indian refrigerator market has seen a strong trend towards larger and more consumptivemore » frost-free units. Room air conditioners in India have traditionally been sold to commercial sector customers, but an increasing number are going to the residential sector. Room air conditioner sales growth in India peaked in the last few years at 20percent per year. In this paper, we perform an engineering-based analysis using data specific to Indian appliances. We evaluate costs and benefits to residential and commercial sector consumers from increased equipment costs and utility bill savings. The analysis finds that, while the BEE scheme presents net benefits to consumers, there remain opportunities for efficiency improvement that would optimize consumer benefits, according to Life Cycle Cost analysis. Due to the large and growing market for refrigerators and air conditioners in India, we forecast large impacts from the standards and labeling program as scheduled. By 2030, this program, if fully implemented would reduce Indian residential electricity consumption by 55 TWh. Overall savings through 2030 totals 385 TWh. Finally, while efficiency levels have been set for several years for refrigerators, labels and MEPS for these products remain voluntary. We therefore consider the negative impact of this delay of implementation to energy and financial savings achievable by 2030.« less
Federal Register 2010, 2011, 2012, 2013, 2014
2013-07-10
.... EERE-2013-BT-STD-0022] RIN 1904-AD00 Energy Efficiency Program for Commercial and Industrial Equipment... the Framework Document pertaining to the development of energy conservation standards for refrigerated...
Final test results for the ground operations demonstration unit for liquid hydrogen
NASA Astrophysics Data System (ADS)
Notardonato, W. U.; Swanger, A. M.; Fesmire, J. E.; Jumper, K. M.; Johnson, W. L.; Tomsik, T. M.
2017-12-01
Described herein is a comprehensive project-a large-scale test of an integrated refrigeration and storage system called the Ground Operations and Demonstration Unit for Liquid Hydrogen (GODU LH2), sponsored by the Advanced Exploration Systems Program and constructed at Kennedy Space Center. A commercial cryogenic refrigerator interfaced with a 125,000 l liquid hydrogen tank and auxiliary systems in a manner that enabled control of the propellant state by extracting heat via a closed loop Brayton cycle refrigerator coupled to a novel internal heat exchanger. Three primary objectives were demonstrating zero-loss storage and transfer, gaseous liquefaction, and propellant densification. Testing was performed at three different liquid hydrogen fill-levels. Data were collected on tank pressure, internal tank temperature profiles, mass flow in and out of the system, and refrigeration system performance. All test objectives were successfully achieved during approximately two years of testing. A summary of the final results is presented in this paper.
NASA Astrophysics Data System (ADS)
Durden, G. L.; Myers, J. O.; Towers, T. A.; Dickman, D. M.
1981-12-01
Noise from air conditioning and refrigeration condensing units is investigated. The practical aspects of attempting to implement innovative approaches are emphasized. These included: (1) sample selection, (2) noise measurement survey, (3) implementation of aggressive abatement procedures, (4) development and use of a screening graph for determining acceptability of sound rated outdoor unitary equipment, (5) incorporation of noise control considerations, (6) exploration of an operatinal curfew, and (7) development of an incentive/information program.
Adding a visualization feature to web search engines: it's time.
Wong, Pak Chung
2008-01-01
It's widely recognized that all Web search engines today are almost identical in presentation layout and behavior. In fact, the same presentation approach has been applied to depicting search engine results pages (SERPs) since the first Web search engine launched in 1993. In this Visualization Viewpoints article, I propose to add a visualization feature to Web search engines and suggest that the new addition can improve search engines' performance and capabilities, which in turn lead to better Web search technology.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shah, Nihar K.; Wei, Max; Letschert, Virginie
Hydrofluorocarbons (HFCs) emitted from uses such as refrigerants and thermal insulating foam, are now the fastest growing greenhouse gases (GHGs), with global warming potentials (GWP) thousands of times higher than carbon dioxide (CO2). Because of the short lifetime of these molecules in the atmosphere,1 mitigating the amount of these short-lived climate pollutants (SLCPs) provides a faster path to climate change mitigation than control of CO2 alone. This has led to proposals from Africa, Europe, India, Island States, and North America to amend the Montreal Protocol on Substances that Deplete the Ozone Layer (Montreal Protocol) to phase-down high-GWP HFCs. Simultaneously, energymore » efficiency market transformation programs such as standards, labeling and incentive programs are endeavoring to improve the energy efficiency for refrigeration and air conditioning equipment to provide life cycle cost, energy, GHG, and peak load savings. In this paper we provide an estimate of the magnitude of such GHG and peak electric load savings potential, for room air conditioning, if the refrigerant transition and energy efficiency improvement policies are implemented either separately or in parallel.« less
Pilot Testing of Commercial Refrigeration-Based Demand Response
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hirsch, Adam; Clark, Jordan; Deru, Michael
Supermarkets potentially offer a substantial demand response (DR) resource because of their high energy intensity and use patterns. This report describes a pilot project conducted to better estimate supermarket DR potential. Previous work has analyzed supermarket DR using heating, ventilating, and air conditioning (HVAC), lighting, and anti-condensate heaters. This project was concerned with evaluating DR using the refrigeration system and quantifying the DR potential inherent in supermarket refrigeration systems. Ancillary aims of the project were to identify practical barriers to the implementation of DR programs in supermarkets and to determine which high-level control strategies were most appropriate for achieving certainmore » DR objectives. The scope of this project does not include detailed control strategy development for DR or development of a strategy for regional implementation of DR in supermarkets.« less
System for and method of freezing biological tissue
NASA Technical Reports Server (NTRS)
Williams, T. E.; Cygnarowicz, T. A. (Inventor)
1978-01-01
Biological tissue is frozen while a polyethylene bag placed in abutting relationship against opposed walls of a pair of heaters. The bag and tissue are cooled with refrigerating gas at a time programmed rate at least equal to the maximum cooling rate needed at any time during the freezing process. The temperature of the bag, and hence of the tissue, is compared with a time programmed desired value for the tissue temperature to derive an error indication. The heater is activated in response to the error indication so that the temperature of the tissue follows the desired value for the time programmed tissue temperature. The tissue is heated to compensate for excessive cooling of the tissue as a result of the cooling by the refrigerating gas. In response to the error signal, the heater is deactivated while the latent heat of fusion is being removed from the tissue while the tissue is changing phase from liquid to solid.
Related Skills in the Marketplace. Final Report.
ERIC Educational Resources Information Center
John C. Calhoun State Community Coll., Decatur, AL.
A study identified related skills needed in five diploma programs offered in the Technical Division of John C. Calhoun State Community College in Decatur, Alabama. The programs were automotive technology, refrigeration/air conditioning, electrical technology, design drafting technology, and cosmetology. Thirty-five area businesses and industries…
15 CFR 9.3 - Appliances and equipment included in program.
Code of Federal Regulations, 2012 CFR
2012-01-01
... and central air conditioners, household refrigerators, home freezers, clothes washers, dishwashers, clothes dryers, kitchen ranges and ovens, water heaters, comfort heating equipment, and television...
15 CFR 9.3 - Appliances and equipment included in program.
Code of Federal Regulations, 2010 CFR
2010-01-01
... and central air conditioners, household refrigerators, home freezers, clothes washers, dishwashers, clothes dryers, kitchen ranges and ovens, water heaters, comfort heating equipment, and television...
15 CFR 9.3 - Appliances and equipment included in program.
Code of Federal Regulations, 2011 CFR
2011-01-01
... and central air conditioners, household refrigerators, home freezers, clothes washers, dishwashers, clothes dryers, kitchen ranges and ovens, water heaters, comfort heating equipment, and television...
15 CFR 9.3 - Appliances and equipment included in program.
Code of Federal Regulations, 2013 CFR
2013-01-01
... and central air conditioners, household refrigerators, home freezers, clothes washers, dishwashers, clothes dryers, kitchen ranges and ovens, water heaters, comfort heating equipment, and television...
15 CFR 9.3 - Appliances and equipment included in program.
Code of Federal Regulations, 2014 CFR
2014-01-01
... and central air conditioners, household refrigerators, home freezers, clothes washers, dishwashers, clothes dryers, kitchen ranges and ovens, water heaters, comfort heating equipment, and television...
Active Refrigeration for Space Astrophysics Missions
NASA Technical Reports Server (NTRS)
Wade, L.
1994-01-01
The use of cryogen dewars limits mission lifetime, increases sensor mass, and increases program engineering and launch costs on spacebased low-background, precision-pointing instruments, telescopes and interferometers.
NASA Astrophysics Data System (ADS)
Shimazaki, Yoichi
The aim of this study was to evaluate the refrigerating and air-conditioning technologies in cases of introducing both cogeneration system and energy network in food industrial park. The energy data of 14 factories were classified into steam, hot water, heating, cooling, refrigerating, freezing and electric power by interviews. The author developed a micro grid model based on linear programming so as to minimize the total system costs. The industrial park was divided into the 2,500 square meter mesh in order to take steam transport into consideration. Four cases were investigated. It was found that the electric power driven freezer was introduced compared with the ammonia absorption freezer. The ammonia absorption freezer was introduced in the factory that there is a little steam demand and large freezing demand at the same time.
Apparatus and method for evaporator defrosting
Mei, Viung C.; Chen, Fang C.; Domitrovic, Ronald E.
2001-01-01
An apparatus and method for warm-liquid defrosting of the evaporator of a refrigeration system. The apparatus includes a first refrigerant expansion device that selectively expands refrigerant for cooling the evaporator, a second refrigerant expansion device that selectively expands the refrigerant after the refrigerant has passed through the evaporator, and a defrosting control for the first refrigerant expansion device and second refrigerant expansion device to selectively defrost the evaporator by causing warm refrigerant to flow through the evaporator. The apparatus is alternately embodied with a first refrigerant bypass and/or a second refrigerant bypass for selectively directing refrigerant to respectively bypass the first refrigerant expansion device and the second refrigerant expansion device, and with the defrosting control connected to the first refrigerant bypass and/or the second refrigerant bypass to selectively activate and deactivate the bypasses depending upon the current cycle of the refrigeration system. The apparatus alternately includes an accumulator for accumulating liquid and/or gaseous refrigerant that is then pumped either to a refrigerant receiver or the first refrigerant expansion device for enhanced evaporator defrosting capability. The inventive method of defrosting an evaporator in a refrigeration system includes the steps of compressing refrigerant in a compressor and cooling the refrigerant in the condenser such that the refrigerant is substantially in liquid form, passing the refrigerant substantially in liquid form through the evaporator, and expanding the refrigerant with a refrigerant expansion device after the refrigerant substantially passes through the evaporator.
Feasibility of an appliance energy testing and labeling program for Sri Lanka
DOE Office of Scientific and Technical Information (OSTI.GOV)
Biermayer, Peter; Busch, John; Hakim, Sajid
2000-04-01
A feasibility study evaluated the costs and benefits of establishing a program for testing, labeling and setting minimum efficiency standards for appliances and lighting in Sri Lanka. The feasibility study included: refrigerators, air-conditioners, flourescent lighting (ballasts & CFls), ceiling fans, motors, and televisions.
1993-01-01
demonstrate improved Pd and Pfa with advanced algorithms, prepare final drop test demonstration. Potential Commercial Market: LADAR profiling and sensing...Field Refrigeration (CRFR) CATEGORY: Exploratory Development OBJECTIVE: To develop a nonpowered (nonelectric) closed-cycle solid-gas sorption
40 CFR 82.38 - Approved independent standards testing organizations.
Code of Federal Regulations, 2014 CFR
2014-07-01
... Recycling Program Manager, Stratospheric Protection Division (6205J), U.S. Environmental Protection Agency... following: (1) That the organization has the capacity to accurately test whether refrigerant recycling...
40 CFR 82.38 - Approved independent standards testing organizations.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Recycling Program Manager, Stratospheric Protection Division (6205J), U.S. Environmental Protection Agency... following: (1) That the organization has the capacity to accurately test whether refrigerant recycling...
40 CFR 82.38 - Approved independent standards testing organizations.
Code of Federal Regulations, 2011 CFR
2011-07-01
... Recycling Program Manager, Stratospheric Protection Division (6205J), U.S. Environmental Protection Agency... following: (1) That the organization has the capacity to accurately test whether refrigerant recycling...
40 CFR 82.38 - Approved independent standards testing organizations.
Code of Federal Regulations, 2012 CFR
2012-07-01
... Recycling Program Manager, Stratospheric Protection Division (6205J), U.S. Environmental Protection Agency... following: (1) That the organization has the capacity to accurately test whether refrigerant recycling...
40 CFR 82.38 - Approved independent standards testing organizations.
Code of Federal Regulations, 2013 CFR
2013-07-01
... Recycling Program Manager, Stratospheric Protection Division (6205J), U.S. Environmental Protection Agency... following: (1) That the organization has the capacity to accurately test whether refrigerant recycling...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-03-11
... grants to Electrolux Home Products, Inc. (Electrolux) a waiver from the DOE electric refrigerator and... procedure that takes this technology into account when measuring energy consumption. DATES: This Decision.... Department of Energy, Building Technologies Program, Mailstop EE-2J, 1000 Independence Avenue, SW...
Illinois Occupational Skill Standards: HVAC/R Technician Cluster.
ERIC Educational Resources Information Center
Illinois Occupational Skill Standards and Credentialing Council, Carbondale.
This document, which is intended to serve as a guide for work force preparation program providers, details the Illinois occupational skill standards for programs preparing students for employment in jobs in the heating, ventilation, air conditioning, and refrigeration (HVAC/R) industry. Agency partners involved in this project include: the…
Federal Register 2010, 2011, 2012, 2013, 2014
2010-04-16
...) Information Collection Request Title: Field Metering of Electrical Appliances; (3) Type of Request: New; (4) Purpose: Metered field data from electrical appliances is necessary to support characterization of energy... Conservation Program for Consumer Products: Survey of Field Energy Consumption of Residential Refrigerators...
Investigation of Energy-Efficient Supermarket Display Cases
DOE Office of Scientific and Technical Information (OSTI.GOV)
Walker, D.H.
Supermarkets represent one of the largest energy-intensive building groups in the commercial sector, consuming 2 to 3 million kWh/yr per store (ES-1). Over half of this energy use is for the refrigeration of food display cases and storage coolers. Display cases are used throughout a supermarket for the merchandising of perishable food products. The cases are maintained at air temperatures ranging from -10 to 35 F, depending upon the type of product stored. The operating characteristics and energy requirements of the refrigeration system are directly related to the refrigeration load. The sources of the display case refrigeration load consist of:more » (1) Moist and warm air infiltration through the open front of the case--air curtains are employed to inhibit this infiltration, but some ambient air is entrained, which adds a substantial portion to the refrigeration load. (2) Heat conduction through case panels and walls. (3) Thermal radiation from the ambient to the product and display case interior. (4) Internal thermal loads--the use of lights, evaporator fans, periodic defrosts, and antisweat heaters adds to the refrigeration load of the display case as well as directly consuming electric energy. The impact of each of these elements on the refrigeration load is very dependent upon case type (Figure ES-1). For example, air infiltration is the most significant portion of the refrigeration load for open, multi-deck cases, while radiation is the largest part of the load for tub-type cases. The door anti-sweat heaters represent a major share of the refrigeration load for frozen food door reach-in cases. Figure ES-2 shows the distribution of display cases in a typical supermarket (ES-2). Open, multi-deck, medium temperature display cases typically comprise about half of the refrigerated fixtures in a store (ES-3). In addition, medium temperature fixtures and storage coolers account for roughly 70 to 75 percent of the total store refrigeration load with open, multi-deck cases contributing about 3/4 of that fraction. Consequently, the focus of this investigation has tilted toward the open, vertical, multi-deck medium temperature case type. Various technologies and control methods are energy efficiency measures (EEMs) that could be applied to display cases and result in the reduction of the refrigeration load and of the energy consumption of the supermarket refrigeration system. An extensive evaluation of the EEMs was conducted in order to select those that met the following criteria: (1) Near-term implementation--All EEMs considered could be implemented with existing refrigeration hardware and technology. (2) Potential for energy-efficiency improvements--Energy savings and/or refrigeration load reduction must be obtained by the implementation of the EEM. (3) Enhancement of the ability to maintain target product temperature--Proper operation of the display case and maintenance of the stored product temperature could not be compromised by the use of the EEM. The energy impact of a number of viable display case EEMs was quantified by performing whole building hourly simulations. A special version of the U.S. Department of Energy's (DOE-2.3) program was used to develop a model of a supermarket. The model was then calibrated using available end-use monitored data to increase confidence in simulation results.« less
NASA Technical Reports Server (NTRS)
Miller, W. S.
1974-01-01
The cryogenic refrigerator thermal design calculations establish design approach and basic sizing of the machine's elements. After the basic design is defined, effort concentrates on matching the thermodynamic design with that of the heat transfer devices (heat exchangers and regenerators). Typically, the heat transfer device configurations and volumes are adjusted to improve their heat transfer and pressure drop characteristics. These adjustments imply that changes be made to the active displaced volumes, compensating for the influence of the heat transfer devices on the thermodynamic processes of the working fluid. Then, once the active volumes are changed, the heat transfer devices require adjustment to account for the variations in flows, pressure levels, and heat loads. This iterative process is continued until the thermodynamic cycle parameters match the design of the heat transfer devices. By examing several matched designs, a near-optimum refrigerator is selected.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-04-06
... to Electrolux Home Products, Inc. (Electrolux) a waiver from the DOE electric refrigerator and... using an alternate test procedure that takes this technology into account when measuring energy.... Michael G. Raymond, U.S. Department of Energy, Building Technologies Program, Mailstop EE-2J, 1000...
Climate Control. Secondary School Course Guide.
ERIC Educational Resources Information Center
DuPlantis, Ernest P.
This course guide is oriented toward developing skills in air conditioning and refrigeration installation and service. Although primarily designed as a 2-year program for high school students at the junior and senior levels, it is equally acceptable for the post high school student as an occupational training program, or as a refresher course for…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gao, Zhiming; Abdelaziz, Omar; LaClair, Tim L.
A refrigerant charge meter and a method for determining the actual refrigerant charge in HVAC systems are described. The meter includes means for determining an optimum refrigerant charge from system subcooling and system component parameters. The meter also includes means for determining the ratio of the actual refrigerant charge to the optimum refrigerant charge. Finally, the meter includes means for determining the actual refrigerant charge from the optimum refrigerant charge and the ratio of the actual refrigerant charge to the optimum refrigerant charge.
Evidence of progress. Measurement of impacts of Australia's S and L program from 1990-2010
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lowenthal-Savy; McNeil, Michael; Harrington, Lloyd
2013-10-15
Australia first put categorical energy efficiency labels on residential appliances in the mid-1980s, and the first Minimum Energy Performance Standards (MEPS) for refrigerators was implemented in 1999. Updated in 2005, these MEPS were aligned with US 2001 levels. Considered together, these actions set Australia apart as having one of the most aggressive appliance efficiency programs in the world. For these reasons, together with good data on product sales over time, Australia represents a potentially fruitful case study for understanding the dynamics energy efficiency standards and labeling (EES and L) programs impacts on appliance markets. This analysis attempts to distinguish betweenmore » the impacts of labeling alone as opposed to MEPS, and to probe the time-dependency of such impacts. Fortunately, in the Australian case, detailed market sales data and a comprehensive registration system provides a solid basis for the empirical evaluation of these questions. This paper analyzes Australian refrigerator efficiency data covering the years 1993-2009. Sales data was purchased from a commercial market research organization (in this case, the GfK Group) and includes sales and average price in each year for each appliance model – this can be used to understand broader trends by product class and star rating category, even where data is aggregated. Statistical regression analysis is used to model market introduction and adoption of high efficiency refrigerators according to logistic adoption model formalism, and parameterizes the way in which the Australian programs accelerated adoption of high-efficiency products and phased out others. Through this analysis, the paper presents a detailed, robust and quantitative picture of the impacts of EES and L in the Australian case, but also demonstrates a methodology of the evaluation of program impacts that could form the basis of an international evaluation framework for similar programs in other countries.« less
Evidence of Progress - Measurement of Impacts of Australia's S&L Program from 1990-2010
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lowenthal-Savy, Danielle; McNeil, Michael; Harrington, Lloyd
2013-09-11
Australia first put categorical energy efficiency labels on residential appliances in the mid-1980s, and the first Minimum Energy Performance Standards (MEPS) for refrigerators was implemented in 1999. Updated in 2005, these MEPS were aligned with US 2001 levels. Considered together, these actions set Australia apart as having one of the most aggressive appliance efficiency programs in the world. For these reasons, together with good data on product sales over time, Australia represents a potentially fruitful case study for understanding the dynamics energy efficiency standards and labeling (EES&L) programs impacts on appliance markets. This analysis attempts to distinguish between the impactsmore » of labeling alone as opposed to MEPS, and to probe the time-dependency of such impacts. Fortunately, in the Australian case, detailed market sales data and a comprehensive registration system provides a solid basis for the empirical evaluation of these questions. This paper analyzes Australian refrigerator efficiency data covering the years 1993-2009. Sales data was purchased from a commercial market research organization (in this case, the GfK Group) and includes sales and average price in each year for each appliance model; this can be used to understand broader trends by product class and star rating category, even where data is aggregated. Statistical regression analysis is used to model market introduction and adoption of high efficiency refrigerators according to logistic adoption model formalism, and parameterizes the way in which the Australian programs accelerated adoption of high-efficiency products and phased out others. Through this analysis, the paper presents a detailed, robust and quantitative picture of the impacts of EES&L in the Australian case, but also demonstrates a methodology of the evaluation of program impacts that could form the basis of an international evaluation framework for similar programs in other countries.« less
NASA Astrophysics Data System (ADS)
Sreenivas, Bura; Nayak, H. Gurudath; Venkatarathnam, G.
2017-01-01
The composition of the refrigerant mixture in circulation during steady state operation of J-T and allied refrigerators is not the same as that charged due to liquid hold up in the heat exchangers and phase separators, as well as the differential solubility of different refrigerant components in the compressor lubricating oil. The performance of refrigerators/liquefiers operating on mixed refrigerant cycles is dependent on the mixture composition. It is therefore important to charge the right mixture that results in an optimum composition in circulation during steady state operation. The relationship between the charged and circulating composition has been experimentally studied in a J-T refrigerator operating in the liquid refrigerant supply (LRS) mode and an auto refrigerant cascade refrigerator (with a phase separator) operating in the gas refrigerant supply (GRS) mode. The results of the study are presented in this work. The results show that the method presented earlier for J-T refrigerators operating in GRS mode is also applicable in the case of refrigerators studied in this work.
Chemically assisted mechanical refrigeration process
Vobach, Arnold R.
1987-01-01
There is provided a chemically assisted mechanical refrigeration process including the steps of: mechanically compressing a refrigerant stream which includes vaporized refrigerant; contacting the refrigerant with a solvent in a mixer (11) at a pressure sufficient to promote substantial dissolving of the refrigerant in the solvent in the mixer (11) to form a refrigerant-solvent solution while concurrently placing the solution in heat exchange relation with a working medium to transfer energy to the working medium, said refrigerant-solvent solution exhibiting a negative deviation from Raoult's Law; reducing the pressure over the refrigerant-solvent solution in an evaporator (10) to allow the refrigerant to vaporize and substantially separate from the solvent while concurrently placing the evolving refrigerant-solvent solution in heat exchange relation with a working medium to remove energy from the working medium to thereby form a refrigerant stream and a solvent stream; and passing the solvent and refrigerant stream from the evaporator.
Chemically assisted mechanical refrigeration process
Vobach, Arnold R.
1987-01-01
There is provided a chemically assisted mechanical refrigeration process including the steps of: mechanically compressing a refrigerant stream which includes vaporized refrigerant; contacting the refrigerant with a solvent in a mixer (11) at a pressure sufficient to promote substantial dissolving of the refrigerant in the solvent in the mixer (11) to form a refrigerant-solvent solution while concurrently placing the solution in heat exchange relation with a working medium to transfer energy to the working medium, said refrigerant-solvent solution exhibiting a negative deviation from Raoult's Law; reducing the pressure over the refrigerant-solvent solution in an evaporator (10) to allow the refrigerant to vaporize and substantially separate from the solvent while concurrently placing he evolving refrigerant-solvent solution in heat exchange relation with a working medium to remove energy from the working medium to thereby form a refrigerant stream and a solvent stream; and passing the solvent and refrigerant stream from the evaporator.
Chemically assisted mechanical refrigeration process
Vobach, A.R.
1987-06-23
There is provided a chemically assisted mechanical refrigeration process including the steps of: mechanically compressing a refrigerant stream which includes vaporized refrigerant; contacting the refrigerant with a solvent in a mixer at a pressure sufficient to promote substantial dissolving of the refrigerant in the solvent in the mixer to form a refrigerant-solvent solution while concurrently placing the solution in heat exchange relation with a working medium to transfer energy to the working medium, said refrigerant-solvent solution exhibiting a negative deviation from Raoult's Law; reducing the pressure over the refrigerant-solvent solution in an evaporator to allow the refrigerant to vaporize and substantially separate from the solvent while concurrently placing the evolving refrigerant-solvent solution in heat exchange relation with a working medium to remove energy from the working medium to thereby form a refrigerant stream and a solvent stream; and passing the solvent and refrigerant stream from the evaporator. 5 figs.
Chemically assisted mechanical refrigeration process
Vobach, A.R.
1987-11-24
There is provided a chemically assisted mechanical refrigeration process including the steps of: mechanically compressing a refrigerant stream which includes vaporized refrigerant; contacting the refrigerant with a solvent in a mixer at a pressure sufficient to promote substantial dissolving of the refrigerant in the solvent in the mixer to form a refrigerant-solvent solution while concurrently placing the solution in heat exchange relation with a working medium to transfer energy to the working medium, said refrigerant-solvent solution exhibiting a negative deviation from Raoult's Law; reducing the pressure over the refrigerant-solvent solution in an evaporator to allow the refrigerant to vaporize and substantially separate from the solvent while concurrently placing the evolving refrigerant-solvent solution in heat exchange relation with a working medium to remove energy from the working medium to thereby form a refrigerant stream and a solvent stream; and passing the solvent and refrigerant stream from the evaporator. 5 figs.
Refrigerant charge management in a heat pump water heater
Chen, Jie; Hampton, Justin W.
2016-07-05
Heat pumps that heat or cool a space and that also heat water, refrigerant management systems for such heat pumps, and methods of managing refrigerant charge. Various embodiments remove idle refrigerant from a heat exchanger that is not needed for transferring heat by opening a refrigerant recovery valve and delivering the idle refrigerant from the heat exchanger to an inlet port on the compressor. The heat exchanger can be isolated by closing an electronic expansion valve, actuating a refrigerant management valve, or both. Refrigerant charge can be controlled by controlling how much refrigerant is drawn from the heat exchanger, by letting some refrigerant back into the heat exchanger, or both. Heat pumps can be operated in different modes of operation, and various components can be interconnected with refrigerant conduit. Some embodiments deliver refrigerant gas to the heat exchanger and drive liquid refrigerant out prior to isolating the heat exchanger.
Floating Loop System For Cooling Integrated Motors And Inverters Using Hot Liquid Refrigerant
Hsu, John S [Oak Ridge, TN; Ayers, Curtis W [Kingston, TN; Coomer, Chester [Knoxville, TN; Marlino, Laura D [Oak Ridge, TN
2006-02-07
A floating loop vehicle component cooling and air-conditioning system having at least one compressor for compressing cool vapor refrigerant into hot vapor refrigerant; at least one condenser for condensing the hot vapor refrigerant into hot liquid refrigerant by exchanging heat with outdoor air; at least one floating loop component cooling device for evaporating the hot liquid refrigerant into hot vapor refrigerant; at least one expansion device for expanding the hot liquid refrigerant into cool liquid refrigerant; at least one air conditioning evaporator for evaporating the cool liquid refrigerant into cool vapor refrigerant by exchanging heat with indoor air; and piping for interconnecting components of the cooling and air conditioning system.
1998-01-01
Biotechnology Refrigerator (BTR) holds fixed tissue culture bags at 4 degrees C to preserve them for return to Earth and postflight analysis. The cultures are used in research with the NASA Bioreactor cell science program. The work is sponsored by NASA's Office of Biological and Physical Research. The bioreactor is managed by the Biotechnology Cell Science Program at NASA's Johnson Space Center (JSC).
Performance of solar refrigerant ejector refrigerating machine
DOE Office of Scientific and Technical Information (OSTI.GOV)
Al-Khalidy, N.A.H.
1997-12-31
In this work a detailed analysis for the ideal, theoretical, and experimental performance of a solar refrigerant ejector refrigerating machine is presented. A comparison of five refrigerants to select a desirable one for the system is made. The theoretical analysis showed that refrigerant R-113 is more suitable for use in the system. The influence of the boiler, condenser, and evaporator temperatures on system performance is investigated experimentally in a refrigerant ejector refrigerating machine using R-113 as a working refrigerant.
Energy Systems Training Programs and Certifications Survey White Paper
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cox, Daryl; Nimbalkar, Sachin U.; Wenning, Thomas J.
2017-02-01
Compressed air system, industrial refrigeration system, chilled water system, pump system, fan system, steam system, process heating system, and combined heat and power system are the major industrial energy systems. By helping enhance knowledge and skills of workforce, training and certification programs on these systems are essential to improve energy efficiency of manufacturing facilities. A literature survey of currently available training and certification programs on these systems was conducted.
Free-cooling: A total HVAC design concept
DOE Office of Scientific and Technical Information (OSTI.GOV)
Janeke, C.E.
1982-01-01
This paper discusses a total ''free cooling'' HVAC design concept in which mechanical refrigeration is practically obviated via the refined application of existing technological strategies and a new diffuser terminal. The principles being applied are as follows; Thermal Swing: This is the active contribution of programmed heat storage to overall HVAC system performance. Reverse Diffuser: This is a new air terminal design that facilitates manifesting the thermal storage gains. Developing the thermal storage equation system into a generalized simulation model, optimizing the thermal storage and operating strategies with a computer program and developing related algorithms are subsequently illustrated. Luminair Aspiration:more » This feature provides for exhausting all luminair heat totally out of the building envelope, via an exhaust duct system and insulated boots. Two/Three-Stage Evaporative Cooling: This concept comprises a system of air conditioning that entails a combination of closed and open loop evaporative cooling with standby refrigeration only.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nelson, Caleb; Reis, Chuck; Nelson, Eric
This report provides guidance for selecting and designing energy efficient commercial refrigeration systems using low global warming potential refrigerants. Refrigeration systems are generally the largest energy end use in a supermarket type building, often accounting for more than half of a building's energy consumption.
Dunne, Suzanne; Cummins, Niamh Maria; Hannigan, Ailish; Shannon, Bill; Dunne, Colum; Cullen, Walter
2013-08-27
The Internet is a widely used source of information for patients searching for medical/health care information. While many studies have assessed existing medical/health care information on the Internet, relatively few have examined methods for design and delivery of such websites, particularly those aimed at the general public. This study describes a method of evaluating material for new medical/health care websites, or for assessing those already in existence, which is correlated with higher rankings on Google's Search Engine Results Pages (SERPs). A website quality assessment (WQA) tool was developed using criteria related to the quality of the information to be contained in the website in addition to an assessment of the readability of the text. This was retrospectively applied to assess existing websites that provide information about generic medicines. The reproducibility of the WQA tool and its predictive validity were assessed in this study. The WQA tool demonstrated very high reproducibility (intraclass correlation coefficient=0.95) between 2 independent users. A moderate to strong correlation was found between WQA scores and rankings on Google SERPs. Analogous correlations were seen between rankings and readability of websites as determined by Flesch Reading Ease and Flesch-Kincaid Grade Level scores. The use of the WQA tool developed in this study is recommended as part of the design phase of a medical or health care information provision website, along with assessment of readability of the material to be used. This may ensure that the website performs better on Google searches. The tool can also be used retrospectively to make improvements to existing websites, thus, potentially enabling better Google search result positions without incurring the costs associated with Search Engine Optimization (SEO) professionals or paid promotion.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bansal, Pradeep; Vineyard, Edward Allan; Abdelaziz, Omar
This paper presents a review of the next generation not-in-kind technologies to replace conventional vapor compression refrigeration technology for household applications. Such technologies are sought to provide energy savings or other environmental benefits for space conditioning, water heating and refrigeration for domestic use. These alternative technologies include: thermoacoustic refrigeration, thermoelectric refrigeration, thermotunneling, magnetic refrigeration, Stirling cycle refrigeration, pulse tube refrigeration, Malone cycle refrigeration, absorption refrigeration, adsorption refrigeration, and compressor driven metal hydride heat pumps. Furthermore, heat pump water heating and integrated heat pump systems are also discussed due to their significant energy saving potential for water heating and space conditioningmore » in households. The paper provides a snapshot of the future R&D needs for each of the technologies along with the associated barriers. Both thermoelectric and magnetic technologies look relatively attractive due to recent developments in the materials and prototypes being manufactured.« less
Miscibility comparison for three refrigerant mixtures and four component refrigerants
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kang, H.M.; Pate, M.B.
1999-07-01
Miscibility data were taken and compared for seven different refrigerants when mixed with the same polyol ester (POE) lubricant. Four of the seven refrigerants were single-component refrigerants while three of the refrigerants were mixtures composed of various combinations of the pure refrigerants. The purpose of this research was to investigate the difference in miscibility characteristics between refrigerant mixtures and their respective component refrigerants. The POE lubricant was a penta erythritol mixed-acid type POE which has a viscosity ISO32. The four pure refrigerants were R-32, R-125, R-134a, and R-143a and the three refrigerant mixtures were R-404A, R407C, and R-410A. The miscibilitymore » tests were performed in a test facility consisting of a series of miniature test cells submerged in a constant temperature bath. The test cells were constructed to allow for complete visibility of the refrigerant/lubricant mixtures under all test conditions. The tests were performed over a concentration range of 0 to 100% and a temperature range of {minus}40 to 194 F. The miscibility test results for refrigerant mixtures are compared to component refrigerants. In all cases, the refrigerant mixtures appear to have better miscibility than their most immiscible pure component.« less
When are solar refrigerators less costly than on-grid refrigerators: A simulation modeling study.
Haidari, Leila A; Brown, Shawn T; Wedlock, Patrick; Connor, Diana L; Spiker, Marie; Lee, Bruce Y
2017-04-19
Gavi recommends solar refrigerators for vaccine storage in areas with less than eight hours of electricity per day, and WHO guidelines are more conservative. The question remains: Can solar refrigerators provide value where electrical outages are less frequent? Using a HERMES-generated computational model of the Mozambique routine immunization supply chain, we simulated the use of solar versus electric mains-powered refrigerators (hereafter referred to as "electric refrigerators") at different locations in the supply chain under various circumstances. At their current price premium, the annual cost of each solar refrigerator is 132% more than each electric refrigerator at the district level and 241% more at health facilities. Solar refrigerators provided savings over electric refrigerators when one-day electrical outages occurred more than five times per year at either the district level or the health facilities, even when the electric refrigerator holdover time exceeded the duration of the outage. Two-day outages occurring more than three times per year at the district level or more than twice per year at the health facilities also caused solar refrigerators to be cost saving. Lowering the annual cost of a solar refrigerator to 75% more than an electric refrigerator allowed solar refrigerators to be cost saving at either level when one-day outages occurred more than once per year, or when two-day outages occurred more than once per year at the district level or even once per year at the health facilities. Our study supports WHO and Gavi guidelines. In fact, solar refrigerators may provide savings in total cost per dose administered over electrical refrigerators when electrical outages are less frequent. Our study identified the frequency and duration at which electrical outages need to occur for solar refrigerators to provide savings in total cost per dose administered over electric refrigerators at different solar refrigerator prices. Copyright © 2017. Published by Elsevier Ltd.
ERIC Educational Resources Information Center
American Society for Engineering Education, Washington, DC.
Occupational and educational information concerning 12 categories of engineering technicians and engineering technology is presented. This information covers the role of the technicians, student qualifications, typical job titles, and typical educational programs. The categories presented are (1) air conditioning, heating, and refrigeration, (2)…
Isolated Apprenticeship Program. Final Report on Phase 2.
ERIC Educational Resources Information Center
New Mexico State Dept. of Education, Santa Fe.
A study is reported on the isolated correspondence courses offered in vocational areas by the New Mexico State Department of Vocational Education. Some courses which were offered were appliance servicing, automobile mechanics, cabinet making, meatcutting, refrigeration, and welding. (Author)
ENERGY STAR Certified Vending Machines
Certified models meet all ENERGY STAR requirements as listed in the Version 3.0 ENERGY STAR Program Requirements for Refrigerated Beverage Vending Machines that are effective as of March 1, 2013. A detailed listing of key efficiency criteria are available at
Combined refrigeration system with a liquid pre-cooling heat exchanger
Gaul, Christopher J.
2003-07-01
A compressor-pump unit for use in a vapor-compression refrigeration system is provided. The compressor-pump unit comprises a driving device including a rotatable shaft. A compressor is coupled with a first portion of the shaft for compressing gaseous refrigerant within the vapor-compression refrigeration system. A liquid pump is coupled with a second portion of the shaft for receiving liquid refrigerant having a first pressure and for discharging the received liquid refrigerant at a second pressure with the second pressure being higher than the first pressure by a predetermined amount such that the discharged liquid refrigerant is subcooled. A pre-cooling circuit is connected to the liquid pump with the pre-cooling circuit being exposed to the gaseous refrigerant whereby the gaseous refrigerant absorbs heat from the liquid refrigerant, prior to the liquid refrigerant entering the liquid pump.
Control method for mixed refrigerant based natural gas liquefier
Kountz, Kenneth J.; Bishop, Patrick M.
2003-01-01
In a natural gas liquefaction system having a refrigerant storage circuit, a refrigerant circulation circuit in fluid communication with the refrigerant storage circuit, and a natural gas liquefaction circuit in thermal communication with the refrigerant circulation circuit, a method for liquefaction of natural gas in which pressure in the refrigerant circulation circuit is adjusted to below about 175 psig by exchange of refrigerant with the refrigerant storage circuit. A variable speed motor is started whereby operation of a compressor is initiated. The compressor is operated at full discharge capacity. Operation of an expansion valve is initiated whereby suction pressure at the suction pressure port of the compressor is maintained below about 30 psig and discharge pressure at the discharge pressure port of the compressor is maintained below about 350 psig. Refrigerant vapor is introduced from the refrigerant holding tank into the refrigerant circulation circuit until the suction pressure is reduced to below about 15 psig, after which flow of the refrigerant vapor from the refrigerant holding tank is terminated. Natural gas is then introduced into a natural gas liquefier, resulting in liquefaction of the natural gas.
ERIC Educational Resources Information Center
Green, Jacob; LeBatard, Ernest; Wiggington, Donnie; Williams, Bennett
2005-01-01
Secondary vocational-technical education programs in Mississippi are faced with many challenges resulting from sweeping educational reforms at the national and state levels. Schools and teachers are increasingly being held accountable for providing true learning activities to every student in the classroom. This accountability is measured through…
SSTAC/ARTS review of the draft Integrated Technology Plan (ITP). Volume 5: Human Support
NASA Technical Reports Server (NTRS)
1991-01-01
Viewgraphs of briefings from the Space Systems and Technology Advisory Committee (SSTAC)/ARTS review of the draft integrated technology plan (ITP) on human support are included. Topics covered include: human support program; human factors; life support technology; fire safety; medical support technology; advanced refrigeration technology; EVA suit system; advanced PLSS technology; and ARC-EVA systems research program.
Mountain Plains Learning Experience Guide: Heating, Refrigeration, & Air Conditioning.
ERIC Educational Resources Information Center
Carey, John
This Heating, Refrigeration, and Air Conditioning course is comprised of eleven individualized units: (1) Refrigeration Tools, Materials, and Refrigerant; (2) Basic Heating and Air Conditioning; (3) Sealed System Repairs; (4) Basic Refrigeration Systems; (5) Compression Systems and Compressors; (6) Refrigeration Controls; (7) Electric Circuit…
Refrigerant directly cooled capacitors
Hsu, John S [Oak Ridge, TN; Seiber, Larry E [Oak Ridge, TN; Marlino, Laura D [Oak Ridge, TN; Ayers, Curtis W [Kingston, TN
2007-09-11
The invention is a direct contact refrigerant cooling system using a refrigerant floating loop having a refrigerant and refrigeration devices. The cooling system has at least one hermetic container disposed in the refrigerant floating loop. The hermetic container has at least one electronic component selected from the group consisting of capacitors, power electronic switches and gating signal module. The refrigerant is in direct contact with the electronic component.
Magnetic refrigeration for maser amplifier cooling
NASA Technical Reports Server (NTRS)
Johnson, D. L.
1982-01-01
The development of a multifrequency upconverter-maser system for the DSN has created the need to develop a closed-cycle refrigerator (CCR) capable of providing more than 3 watts of refrigeration capability at 4.5 K. In addition, operating concerns such as the high cost of electrical power consumption and the loss of maser operation due to CCR failures require that improvements be made to increase the efficiency and reliability of the CCR. One refrigeration method considered is the replacement of the Joule-Thomson expansion circuit with a magnetic refrigeration. Magnetic refrigerators can provide potentially reliable and highly efficient refrigeration at a variety of temperature ranges and cooling power. The concept of magnetic refrigeration is summarized and a literature review of existing magnetic refrigerator designs which have been built and tested and that may also be considered as possibilities as a 4 K to 15 K magnetic refrigeration stage for the DSN closed-cycle refrigerator is provided.
Refrigerant charge management in a heat pump water heater
Chen, Jie; Hampton, Justin W.
2014-06-24
Heat pumps that heat or cool a space and that also heat water, refrigerant management systems for such heat pumps, methods of managing refrigerant charge, and methods for heating and cooling a space and heating water. Various embodiments deliver refrigerant gas to a heat exchanger that is not needed for transferring heat, drive liquid refrigerant out of that heat exchanger, isolate that heat exchanger against additional refrigerant flowing into it, and operate the heat pump while the heat exchanger is isolated. The heat exchanger can be isolated by closing an electronic expansion valve, actuating a refrigerant management valve, or both. Refrigerant charge can be controlled or adjusted by controlling how much liquid refrigerant is driven from the heat exchanger, by letting refrigerant back into the heat exchanger, or both. Heat pumps can be operated in different modes of operation, and segments of refrigerant conduit can be interconnected with various components.
Refrigeration oils for low GWP refrigerants in various applications
NASA Astrophysics Data System (ADS)
Saito, R.; Sundaresan, S. G.
2017-08-01
The practical use of the refrigeration systems is considered as a methods to suppress global warming. The replacement of a refrigerant with a new one that has lower global warming potential (GWP) has been underway for several years. For the application fields of refrigerators, domestic air conditioners, automotive air conditioners and hot water dispensers, the investigation has almost finished. It is still underway for the application fields of commercial air conditioners and chillers, refrigeration facilities for cold storage, etc. And now, the refrigeration system is being applied in various ways to decrease global warming above the generation of electric power with organic Rankine cycle, the binary electric generation with ground source heat pump, and so on. In these situations, various refrigerants are developed and several kinds of suitable refrigeration oils are selected. This paper presents the consideration of suitable refrigeration oil for the various low GWP refrigerants.
When are solar refrigerators less costly than on-grid refrigerators: A simulation modeling study☆
Haidari, Leila A.; Brown, Shawn T.; Wedlock, Patrick; Connor, Diana L.; Spiker, Marie; Lee, Bruce Y.
2017-01-01
Background Gavi recommends solar refrigerators for vaccine storage in areas with less than eight hours of electricity per day, and WHO guidelines are more conservative. The question remains: Can solar refrigerators provide value where electrical outages are less frequent? Methods Using a HERMES-generated computational model of the Mozambique routine immunization supply chain, we simulated the use of solar versus electric mains-powered refrigerators (hereafter referred to as “electric refrigerators”) at different locations in the supply chain under various circumstances. Results At their current price premium, the annual cost of each solar refrigerator is 132% more than each electric refrigerator at the district level and 241% more at health facilities. Solar refrigerators provided savings over electric refrigerators when one-day electrical outages occurred more than five times per year at either the district level or the health facilities, even when the electric refrigerator holdover time exceeded the duration of the outage. Two-day outages occurring more than three times per year at the district level or more than twice per year at the health facilities also caused solar refrigerators to be cost saving. Lowering the annual cost of a solar refrigerator to 75% more than an electric refrigerator allowed solar refrigerators to be cost saving at either level when one-day outages occurred more than once per year, or when two-day outages occurred more than once per year at the district level or even once per year at the health facilities. Conclusion Our study supports WHO and Gavi guidelines. In fact, solar refrigerators may provide savings in total cost per dose administered over electrical refrigerators when electrical outages are less frequent. Our study identified the frequency and duration at which electrical outages need to occur for solar refrigerators to provide savings in total cost per dose administered over electric refrigerators at different solar refrigerator prices. PMID:28364935
Lee, Bruce Y; Assi, Tina-Marie; Rajgopal, Jayant; Norman, Bryan A; Chen, Sheng-I; Brown, Shawn T; Slayton, Rachel B; Kone, Souleymane; Kenea, Hailu; Welling, Joel S; Connor, Diana L; Wateska, Angela R; Jana, Anirban; Wiringa, Ann E; Van Panhuis, Willem G; Burke, Donald S
2012-02-01
We investigated whether introducing the rotavirus and pneumococcal vaccines, which are greatly needed in West Africa, would overwhelm existing supply chains (i.e., the series of steps required to get a vaccine from the manufacturers to the target population) in Niger. As part of the Bill and Melinda Gates Foundation-funded Vaccine Modeling Initiative, we developed a computational model to determine the impact of introducing these new vaccines to Niger's Expanded Program on Immunization vaccine supply chain. Introducing either the rotavirus vaccine or the 7-valent pneumococcal conjugate vaccine could overwhelm available storage and transport refrigerator space, creating bottlenecks that would prevent the flow of vaccines down to the clinics. As a result, the availability of all World Health Organization Expanded Program on Immunization vaccines to patients might decrease from an average of 69% to 28.2% (range = 10%-51%). Addition of refrigerator and transport capacity could alleviate this bottleneck. Our results suggest that the effects on the vaccine supply chain should be considered when introducing a new vaccine and that computational models can help assess evolving needs and prevent problems with vaccine delivery.
Monitoring adherence to cold chain storage of vaccines in 2014 in the Małopolska province
Wiercińska, Ewa; Orzeł-Nowak, Anita; Mrozowska, Barbara; Foremny, Jarosław
2017-01-01
The principles of „cold chain” have been developed for the safe transport and storage of vaccines because of their sensitivity to temperature and are guidelines for use in all countries. Available information on adherence to the principles of the “cold chain” by healthcare providers in Poland is insufficient. The aim of the study was to assess compliance with these rules in storing vaccines by vaccination centers implementing an immunization program in 2014 in the Malopolska province The study was conducted in 111 vaccination centers in 19 districts of Malopolska, which represents 12% of all vaccination centers in the Malopolska province in 2014. The selection of vaccination centers for the study was not random. During a routine inspection of vaccination centers, an employee of the District Sanitary-Epidemiological Station conducted a study using a specially-prepared questionnaire. Inspections in vaccination centers which qualified for the study were conducted from March to September 2015. Among the analyzed vaccinations centers 90% had a refrigerator or refrigerator-freezer, and 10% a pharmaceutical refrigerator. 3.6% of refrigerators were produced before 2000. A 24-hour recording of the temperature was conducted in 67.6% vaccination centers. 40.5% of vaccination centers had a 24-hour system of recording and notification when temperature parameters had been exceeded in refrigeration devices. 22.5% of vaccination centers had emergency power supply. 13.5% of vaccination centers a power failure occurred in refrigerators, including 40% of the vaccination centers which had a text message notification system.. Total cost of destroyed vaccines amounted to over 20 thousand zl. Correct storage conditions are needed for vaccines to maintain their full effectiveness, which is why it is necessary to intensify efforts to ensure compliance with the principles of the cold chain in the storage of vaccines by healthcare providers.
Magnetic Refrigeration Development
NASA Technical Reports Server (NTRS)
Deardoff, D. D.; Johnson, D. L.
1984-01-01
Magnetic refrigeration is being developed to determine whether it may be used as an alternative to the Joule-Thomson circuit of a closed cycle refrigerator for providing 4 K refrigeration. An engineering model 4-15 K magnetic refrigerator has been designed and is being fabricated. This article describes the overall design of the magnetic refrigerator.
Energy Efficient Commercial Refrigeration with Carbon Dioxide Refrigerant and Scroll Expanders
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dieckmann, John
Current supermarket refrigeration systems are built around conventional fluorocarbon refrigerants – HFC-134a and the HFC blends R-507 and R404A, which replaced the CFC refrigerants, R-12 and R-502, respectively, used prior to the Montreal Protocol phase out of ozone depleting substances. While the HFC refrigerants are non-ozone depleting, they are strong greenhouse gases, so there has been continued interest in replacing them, particularly in applications with above average refrigerant leakage. Large supermarket refrigeration systems have proven to be particularly difficult to maintain in a leak-tight condition. Refrigerant charge losses of 15% of total charge per year are the norm, making themore » global warming impact of refrigerant emissions comparable to that associated with the energy consumption of these systems.« less
Non-intrusive refrigerant charge indicator
Mei, Viung C.; Chen, Fang C.; Kweller, Esher
2005-03-22
A non-intrusive refrigerant charge level indicator includes a structure for measuring at least one temperature at an outside surface of a two-phase refrigerant line section. The measured temperature can be used to determine the refrigerant charge status of an HVAC system, and can be converted to a pressure of the refrigerant in the line section and compared to a recommended pressure range to determine whether the system is under-charged, properly charged or over-charged. A non-intrusive method for assessing the refrigerant charge level in a system containing a refrigerant fluid includes the step of measuring a temperature at least one outside surface of a two-phase region of a refrigerant containing refrigerant line, wherein the temperature measured can be converted to a refrigerant pressure within the line section.
40 CFR 63.427 - Continuous monitoring.
Code of Federal Regulations, 2010 CFR
2010-07-01
... concentration shall be installed in the exhaust air stream. (2) Where a refrigeration condenser system is used... 63.427 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) NATIONAL EMISSION STANDARDS FOR HAZARDOUS AIR POLLUTANTS FOR SOURCE CATEGORIES National Emission Standards...
Thermoelectric refrigerator having improved temperature stabilization means
Falco, Charles M.
1982-01-01
A control system for thermoelectric refrigerators is disclosed. The thermoelectric refrigerator includes at least one thermoelectric element that undergoes a first order change at a predetermined critical temperature. The element functions as a thermoelectric refrigerator element above the critical temperature, but discontinuously ceases to function as a thermoelectric refrigerator element below the critical temperature. One example of such an arrangement includes thermoelectric refrigerator elements which are superconductors. The transition temperature of one of the superconductor elements is selected as the temperature control point of the refrigerator. When the refrigerator attempts to cool below the point, the metals become superconductors losing their ability to perform as a thermoelectric refrigerator. An extremely accurate, first-order control is realized.
Direct condensation refrigerant recovery and restoration system
DOE Office of Scientific and Technical Information (OSTI.GOV)
Grant, D.C.H.
1992-03-10
This patent describes a refrigerant recovery and purification system for removing gaseous refrigerant from a disabled refrigeration unit, cleaning the refrigerant of contaminants, and converting the gaseous refrigerant to a liquid state for storage. It comprises a low pressure inlet section; a high pressure storage section; the low pressure inlet section comprising: an oil and refrigerant gas separator, including a separated oil removal means, first conduit means for connecting an inlet of the separator to the disabled refrigerant unit, a slack-sided accumulator, second conduit means connecting the separator to the slack-sided accumulator, a reclaim condenser, third conduit means connecting themore » separator and the reclaim condenser in series, an evaporator coil in the reclaim condenser connectable to a conventional operating refrigeration system for receiving a liquid refrigerant under pressure for expansion therein, the evaporator coil forming a condensing surface for condensing the refrigerant gas at near atmospheric pressure in the condenser, a liquid receiver, a reclaimed refrigerant storage tank, fourth conduit means further connecting the liquid receiver in series with the reclaim condenser, downstream thereof, means between the reclaim condenser and the liquid receiver.« less
Heat pump employing optimal refrigerant compressor for low pressure ratio applications
Ecker, Amir L.
1982-01-01
What is disclosed is a heat pump apparatus for conditioning a fluid characterized by a fluid handler for circulating the fluid in heat exchange relationship with a refrigerant fluid; two refrigerant heat exchangers; one for effecting the heat exchange with the fluid and a second refrigerant-heat exchange fluid heat exchanger for effecting a low pressure ratio of compression of the refrigerant; a rotary compressor for compressing the refrigerant with low power consumption at the low pressure ratio; at least one throttling valve connecting at the inlet side of heat exchanger in which liquid refrigerant is vaporized; a refrigerant circuit serially connecting the above elements; refrigerant in the circuit; a source of heat exchange fluid; heat exchange fluid circulating device and heat exchange fluid circuit for circulating the heat exchange fluid in heat exchange relationship with the refrigerant.
Dual-circuit, multiple-effect refrigeration system and method
DeVault, Robert C.
1995-01-01
A dual circuit absorption refrigeration system comprising a high temperature single-effect refrigeration loop and a lower temperature double-effect refrigeration loop separate from one another and provided with a double-condenser coupling therebetween. The high temperature condenser of the single-effect refrigeration loop is double coupled to both of the generators in the double-effect refrigeration loop to improve internal heat recovery and a heat and mass transfer additive such as 2-ethyl-1-hexanol is used in the lower temperature double-effect refrigeration loop to improve the performance of the absorber in the double-effect refrigeration loop.
Floating loop method for cooling integrated motors and inverters using hot liquid refrigerant
Hsu, John S.; Ayers, Curtis W.; Coomer, Chester; Marlino, Laura D.
2007-03-20
A method for cooling vehicle components using the vehicle air conditioning system comprising the steps of: tapping the hot liquid refrigerant of said air conditioning system, flooding a heat exchanger in the vehicle component with said hot liquid refrigerant, evaporating said hot liquid refrigerant into hot vapor refrigerant using the heat from said vehicle component, and returning said hot vapor refrigerant to the hot vapor refrigerant line in said vehicle air conditioning system.
An approach for cooling by solar energy
NASA Astrophysics Data System (ADS)
Rabeih, S. M.; Wahhab, M. A.; Asfour, H. M.
The present investigation is concerned with the possibility to base the operation of a household refrigerator on solar energy instead of gas fuel. The currently employed heating system is to be replaced by a solar collector with an absorption area of two sq m. Attention is given to the required changes in the generator design, the solar parameters at the location of refrigerator installation, the mathematical approach for the thermal analysis of the solar collector, the development of a computer program for the evaluation of the important parameters, the experimental test rig, and the measurement of the experimental parameters. A description is given of the obtained optimum operating conditions for the considered system.
NASA Technical Reports Server (NTRS)
1994-01-01
Early in the space program, NASA recognized the need to replace bulky coils, compressers, and motors for refrigeration purposes by looking at existing thermoelectric technology. This effort resulted in the development of miniaturized thermoelectric components and packaging to accommodate tight confines of spacecraft. Koolatron's portable electronic refrigerators incorporate this NASA technology. Each of the cooler/warmers employs one or two miniaturized thermoelectric modules. Although each module is only the size of a book of matches, it delivers the cooling power of a 10-pound block of ice. In some models, the cooler can be converted to a warmer. There are no moving parts. The Koolatrons can be plugged into auto cigarette lighters, recreational vehicles, boats or motel outlets.
Research and Development Opportunities for Joining Technologies in HVAC&R
DOE Office of Scientific and Technical Information (OSTI.GOV)
Goetzler, William; Guernsey, Matt; Young, Jim
The Building Technologies Office (BTO) works with researchers and industry partners to develop and deploy technologies that can substantially reduce energy consumption and greenhouse gas (GHG) emissions in residential and commercial buildings. This opportunity assessment aims to advance BTO’s energy savings, GHG reduction, and other program goals by identifying research and development (R&D) initiatives for joining technologies in heating, ventilation, air-conditioning, and refrigeration (HVAC&R) systems. Improving joining technologies for HVAC&R equipment has the potential to increase lifetime equipment operating efficiency, decrease equipment and project cost, and most importantly reduce hydroflourocarbon (HFC) refrigerant leakage to support HFC phasedown and GHG reductionmore » goals.« less
Refrigerant pressurization system with a two-phase condensing ejector
Bergander, Mark [Madison, CT
2009-07-14
A refrigerant pressurization system including an ejector having a first conduit for flowing a liquid refrigerant therethrough and a nozzle for accelerating a vapor refrigerant therethrough. The first conduit is positioned such that the liquid refrigerant is discharged from the first conduit into the nozzle. The ejector includes a mixing chamber for condensing the vapor refrigerant. The mixing chamber comprises at least a portion of the nozzle and transitions into a second conduit having a substantially constant cross sectional area. The condensation of the vapor refrigerant in the mixing chamber causes the refrigerant mixture in at least a portion of the mixing chamber to be at a pressure greater than that of the refrigerant entering the nozzle and greater than that entering the first conduit.
Rural health clinics infrastructure
DOE Office of Scientific and Technical Information (OSTI.GOV)
Olson, K.
1997-12-01
The author discusses programs which were directed at the installation of photovoltaic power systems in rural health clinics. The objectives included: vaccine refrigeration; ice pack freezing; lighting; communications; medical appliances; sterilization; water purification; and income generation. The paper discusses two case histories, one in the Dominican Republic and one in Colombia. The author summarizes the results of the programs, both successes and failures, and offers an array of conclusions with regard to the implementation of future programs of this general nature.
ERIC Educational Resources Information Center
Snow, Rufus; And Others
As a part of the REACH (Refrigeration, Electro-Mechanical, Air-Conditioning, Heating) electromechanical cluster, this student manual contains individualized instructional units in the area of refrigeration. The instructional units focus on refrigeration fundamentals, tubing and pipe, refrigerants, troubleshooting, window air conditioning, and…
Refrigeration system oil measurement and sampling device
DOE Office of Scientific and Technical Information (OSTI.GOV)
Baker, J.A.
1989-09-19
This patent describes a sampling device for use with a refrigeration system having a refrigerant and oil entrained therein. It comprises: an elongated reservoir having a stepped bore therein for receiving refrigerant and oil carried thereby. The reservoir comprising a large bore diameter upper section having an index marking the fill level of the reservoir and a small bore diameter lower section having graduation marks for oil level measurement. The upper and lower sections comprising transparent material to allow observation of the contents, first valve means for coupling the reservoir to the refrigeration system to admit liquid refrigerant to themore » reservoir, second valve means for selectively coupling the reservoir to the low pressure side of the refrigeration system or to a vacuum line to evacuate vaporized refrigerant from the reservoir, and means for supplying heat to the refrigerant in the bore to facilitate vaporization of the refrigerant.« less
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 18 2014-07-01 2014-07-01 false Prohibitions. 82.304 Section 82.304 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) PROTECTION OF STRATOSPHERIC OZONE Ban on Refrigeration and Air-Conditioning Appliances Containing HCFCs § 82.304 Prohibitions...
DEMONSTRATION OF VAPOR CONTROL TECHNOLOGY FOR GASOLINE LOADING OF BARGES
The report gives results of a program to demonstrate a safe cost-effective way to control gasoline vapors emitted during barge loading. Refrigeration, carbon adsorption, oil absorption, and incineration were reviewed in terms of their safety, economics, and performance. Two barge...
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 18 2014-07-01 2014-07-01 false Definitions. 82.302 Section 82.302 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) PROTECTION OF STRATOSPHERIC OZONE Ban on Refrigeration and Air-Conditioning Appliances Containing HCFCs § 82.302 Definitions...
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 18 2014-07-01 2014-07-01 false Purpose. 82.300 Section 82.300 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) PROTECTION OF STRATOSPHERIC OZONE Ban on Refrigeration and Air-Conditioning Appliances Containing HCFCs § 82.300 Purpose. The...
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 17 2010-07-01 2010-07-01 false Definitions. 82.302 Section 82.302 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) PROTECTION OF STRATOSPHERIC OZONE Ban on Refrigeration and Air-Conditioning Appliances Containing HCFCs § 82.302 Definitions...
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 17 2011-07-01 2011-07-01 false Definitions. 82.302 Section 82.302 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) PROTECTION OF STRATOSPHERIC OZONE Ban on Refrigeration and Air-Conditioning Appliances Containing HCFCs § 82.302 Definitions...
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 18 2012-07-01 2012-07-01 false Definitions. 82.302 Section 82.302 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) PROTECTION OF STRATOSPHERIC OZONE Ban on Refrigeration and Air-Conditioning Appliances Containing HCFCs § 82.302 Definitions...
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 18 2013-07-01 2013-07-01 false Prohibitions. 82.304 Section 82.304 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) PROTECTION OF STRATOSPHERIC OZONE Ban on Refrigeration and Air-Conditioning Appliances Containing HCFCs § 82.304 Prohibitions...
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 18 2012-07-01 2012-07-01 false Prohibitions. 82.304 Section 82.304 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) PROTECTION OF STRATOSPHERIC OZONE Ban on Refrigeration and Air-Conditioning Appliances Containing HCFCs § 82.304 Prohibitions...
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 18 2012-07-01 2012-07-01 false Purpose. 82.300 Section 82.300 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) PROTECTION OF STRATOSPHERIC OZONE Ban on Refrigeration and Air-Conditioning Appliances Containing HCFCs § 82.300 Purpose. The...
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 18 2013-07-01 2013-07-01 false Definitions. 82.302 Section 82.302 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) PROTECTION OF STRATOSPHERIC OZONE Ban on Refrigeration and Air-Conditioning Appliances Containing HCFCs § 82.302 Definitions...
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 17 2011-07-01 2011-07-01 false Prohibitions. 82.304 Section 82.304 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) PROTECTION OF STRATOSPHERIC OZONE Ban on Refrigeration and Air-Conditioning Appliances Containing HCFCs § 82.304 Prohibitions...
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 17 2010-07-01 2010-07-01 false Purpose. 82.300 Section 82.300 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) PROTECTION OF STRATOSPHERIC OZONE Ban on Refrigeration and Air-Conditioning Appliances Containing HCFCs § 82.300 Purpose. The...
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 18 2013-07-01 2013-07-01 false Purpose. 82.300 Section 82.300 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) PROTECTION OF STRATOSPHERIC OZONE Ban on Refrigeration and Air-Conditioning Appliances Containing HCFCs § 82.300 Purpose. The...
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 17 2010-07-01 2010-07-01 false Prohibitions. 82.304 Section 82.304 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) PROTECTION OF STRATOSPHERIC OZONE Ban on Refrigeration and Air-Conditioning Appliances Containing HCFCs § 82.304 Prohibitions...
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 17 2011-07-01 2011-07-01 false Purpose. 82.300 Section 82.300 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) PROTECTION OF STRATOSPHERIC OZONE Ban on Refrigeration and Air-Conditioning Appliances Containing HCFCs § 82.300 Purpose. The...
Segovia, M.; Jenkins, J.A.; Paniagua-Chavez, C.; Tiersch, T.R.
2000-01-01
Improved techniques for storage and evaluation of fish sperm would enhance breeding programs around the world. The goal of this study was to test the effect of antibiotics on refrigerated sperm from Nile tilapia (Oreochromis niloticus) by use of flow cytometry with 2 dual-staining protocols for objective assessment of sperm quality. Concentrations of 1 x 109 sperm/mL were suspended in Ringer's buffer at 318 mOsmol/kg (pH 8.0). The fluorescent stains Sybr 14 (10 ??M), propidium iodide (2.4 mM), and rhodamine 123 (0.13 ??M) were used to assess cell viability and mitochondrial function. Three concentrations of ampicillin, gentamicin, and an antibiotic/antimycotic solution were added to fresh spermatozoa. Motility estimates and flow cytometry measurements were made daily during 7 d of refrigerated storage (4 ??C). The highest concentrations of gentamicin and antibiotic/antimycotic and all 3 concentrations of ampicillin significantly reduced sperm viability. The highest of each of the 3 antibiotic concentrations significantly reduced mitochondrial function. This study demonstrates that objective sperm quality assessments can be made using flow cytometry and that addition of antibiotics at appropriate concentrations can lengthen refrigerated storage time for tilapia spermatozoa. With minor modifications, these protocols can be adapted for use with sperm from other species and with other tissue types.
Integrated Refrigeration and Storage for Advanced Liquid Hydrogen Operations
NASA Technical Reports Server (NTRS)
Swanger, A. M.; Notardonato, W. U.; Johnson, W. L.; Tomsik, T. M.
2016-01-01
NASA has used liquefied hydrogen (LH2) on a large scale since the beginning of the space program as fuel for the Centaur and Apollo upper stages, and more recently to feed the three space shuttle main engines. The LH2 systems currently in place at the Kennedy Space Center (KSC) launch pads are aging and inefficient compared to the state-of-the-art. Therefore, the need exists to explore advanced technologies and operations that can drive commodity costs down, and provide increased capabilities. The Ground Operations Demonstration Unit for Liquid Hydrogen (GODU-LH2) was developed at KSC to pursue these goals by demonstrating active thermal control of the propellant state by direct removal of heat using a cryocooler. The project has multiple objectives including zero loss storage and transfer, liquefaction of gaseous hydrogen, and densification of liquid hydrogen. The key technology challenge was efficiently integrating the cryogenic refrigerator into the LH2 storage tank. A Linde LR1620 Brayton cycle refrigerator is used to produce up to 900W cooling at 20K, circulating approximately 22 g/s gaseous helium through the hydrogen via approximately 300 m of heat exchanger tubing. The GODU-LH2 system is fully operational, and is currently under test. This paper will discuss the design features of the refrigerator and storage system, as well as the current test results.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Calm, J.M.
1998-03-15
The Refrigerant Database is an information system on alternative refrigerants, associated lubricants, and their use in air conditioning and refrigeration. It consolidates and facilitates access to thermophysical properties, compatibility, environmental, safety, application and other information. It provides corresponding information on older refrigerants, to assist manufacturers and those using alternative refrigerants, to make comparisons and determine differences. The underlying purpose is to accelerate phase out of chemical compounds of environmental concern. The database provides bibliographic citations and abstracts for publications that may be useful in research and design of air conditioning and refrigeration equipment. It also references documents addressing compatibility ofmore » refrigerants and lubricants with other materials.« less
NASA Astrophysics Data System (ADS)
Poese, Matthew E.; Smith, Robert W. M.; Garrett, Steven L.
2005-09-01
This talk will compare electrodynamically driven thermoacoustic refrigeration technology to some common implementations of low-lift vapor-compression technology. A rudimentary explanation of vapor-compression refrigeration will be presented along with some of the implementation problems faced by refrigeration engineers using compressor-based systems. These problems include oil management, compressor slugging, refrigerant leaks and the environmental impact of refrigerants. Recently, the method of evaluating this environmental impact has been codified to include the direct effects of the refrigerants on global warming as well as the so-called ``indirect'' warming impact of the carbon dioxide released during the generation (at the power plant) of the electrical power consumed by the refrigeration equipment. It is issues like these that generate commercial interest in an alternative refrigeration technology. However, the requirements of a candidate technology for adoption in a mature and risk-averse commercial refrigeration industry are as hard to divine as they are to meet. Also mentioned will be the state of other alternative refrigeration technologies like free-piston Stirling, thermoelectric and magnetocaloric as well as progress using vapor compression technology with alternative refrigerants like hydrocarbons and carbon dioxide.
The Atmospheric Protection Branch's Refrigeration Applications Laboratory has the capability to test several types of refrigeration equipment with various refrigerants. Refrigeration compressors are tested according to the ANSI/ASHRAE 23-1993 Test Standard and under various oper...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Calm, J.M.
1996-07-01
The Refrigerant Database is an information system on alternative refrigerants, associated lubricants, and their use in air conditioning and refrigeration. It consolidates and facilitates access to property, compatibility, environmental, safety, application and other information. It provides corresponding information on older refrigerants, to assist manufacturers and those using alternative refrigerants, to make comparisons and determine differences. The underlying purpose is to accelerate phase out of chemical compounds of environmental concern.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Calm, J.M.
1996-11-15
The Refrigerant Database is an information system on alternative refrigerants, associated lubricants, and their use in air conditioning and refrigeration. It consolidates and facilitates access to property, compatibility, environmental, safety, application and other information. It provides corresponding information on older refrigerants, to assist manufacturers and those using alternative refrigerants, to make comparisons and determine differences. The underlying purpose is to accelerate phase out of chemical compounds of environmental concern.
Evaluation of Five Sedimentary Rocks Other Than Salt for Geologic Repository Siting Purposes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Croff, A.G.; Lomenick, T.F.; Lowrie, R.S.
The US Department of Energy (DOE), in order to increase the diversity of rock types under consideration by the geologic disposal program, initiated the Sedimary ROck Program (SERP), whose immediate objectiv eis to evaluate five types of secimdnary rock - sandstone, chalk, carbonate rocks (limestone and dolostone), anhydrock, and shale - to determine the potential for siting a geologic repository. The evaluation of these five rock types, together with the ongoing salt studies, effectively results in the consideration of all types of relatively impermeable sedimentary rock for repository purposes. The results of this evaluation are expressed in terms of amore » ranking of the five rock types with respect to their potential to serve as a geologic repository host rock. This comparative evaluation was conducted on a non-site-specific basis, by use of generic information together with rock evaluation criteria (RECs) derived from the DOE siting guidelines for geologic repositories (CFR 1984). An information base relevant to rock evaluation using these RECs was developed in hydrology, geochemistry, rock characteristics (rock occurrences, thermal response, rock mechanics), natural resources, and rock dissolution. Evaluation against postclosure and preclosure RECs yielded a ranking of the five subject rocks with respect to their potential as repository host rocks. Shale was determined to be the most preferred of the five rock types, with sandstone a distant second, the carbonate rocks and anhydrock a more distant third, and chalk a relatively close fourth.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Abdelaziz, Omar; Fricke, Brian A; Vineyard, Edward Allan
Commercial refrigeration systems are known to be prone to high leak rates and to consume large amounts of electricity. As such, direct emissions related to refrigerant leakage and indirect emissions resulting from primary energy consumption contribute greatly to their Life Cycle Climate Performance (LCCP). In this paper, an LCCP design tool is used to evaluate the performance of a typical commercial refrigeration system with alternative refrigerants and minor system modifications to provide lower Global Warming Potential (GWP) refrigerant solutions with improved LCCP compared to baseline systems. The LCCP design tool accounts for system performance, ambient temperature, and system load; systemmore » performance is evaluated using a validated vapor compression system simulation tool while ambient temperature and system load are devised from a widely used building energy modeling tool (EnergyPlus). The LCCP design tool also accounts for the change in hourly electricity emission rate to yield an accurate prediction of indirect emissions. The analysis shows that conventional commercial refrigeration system life cycle emissions are largely due to direct emissions associated with refrigerant leaks and that system efficiency plays a smaller role in the LCCP. However, as a transition occurs to low GWP refrigerants, the indirect emissions become more relevant. Low GWP refrigerants may not be suitable for drop-in replacements in conventional commercial refrigeration systems; however some mixtures may be introduced as transitional drop-in replacements. These transitional refrigerants have a significantly lower GWP than baseline refrigerants and as such, improved LCCP. The paper concludes with a brief discussion on the tradeoffs between refrigerant GWP, efficiency and capacity.« less
Keeping Cool With Solar-Powered Refrigeration
NASA Technical Reports Server (NTRS)
2003-01-01
In the midst of developing battery-free, solar-powered refrigeration and air conditioning systems for habitats in space, David Bergeron, the team leader for NASA's Advanced Refrigerator Technology Team at Johnson Space Center, acknowledged the need for a comparable solar refrigerator that could operate in conjunction with the simple lighting systems already in place on Earth. Bergeron, a 20-year veteran in the aerospace industry, founded the company Solus Refrigeration, Inc., in 1999 to take the patented advanced refrigeration technology he co-developed with his teammate, Johnson engineer Michael Ewert, to commercial markets. Now known as SunDanzer Refrigeration, Inc., Bergeron's company is producing battery-free, photovoltaic (PV) refrigeration systems under license to NASA, and selling them globally.
A review of pulse tube refrigeration
NASA Technical Reports Server (NTRS)
Radebaugh, Ray
1990-01-01
This paper reviews the development of the three types of pulse tube refrigerators: basic, resonant, and orifice types. The principles of operation are given. It is shown that the pulse tube refrigerator is a variation of the Stirling-cycle refrigerator, where the moving displacer is substituted by a heat transfer mechanism or by an orifice to bring about the proper phase shifts between pressure and mass flow rate. A harmonic analysis with phasors is described which gives reasonable results for the refrigeration power, yet is simple enough to make clear the processes which give rise to the refrigeration. The efficiency and refrigeration power are compared with those of other refrigeration cycles. A brief review is given of the research being done at various laboratories on both one- and two-stage pulse tubes. A preliminary assessment of the role of pulse tube refrigerators is discussed.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-12-14
... used as refrigerants during the service, maintenance, repair, or disposal of refrigeration and air... person in the course of maintaining, servicing, repairing, or disposing of refrigeration or air...-depleting refrigerants recovered during the servicing and disposal of air-conditioning and refrigeration...
10 CFR 431.62 - Definitions concerning commercial refrigerators, freezers and refrigerator-freezers.
Code of Federal Regulations, 2012 CFR
2012-01-01
... transparent or solid doors, sliding or hinged doors, a combination of hinged, sliding, transparent, or solid... compressors, refrigerant condensers, condenser fans and motors, and factory supplied accessories. Self... more refrigerant compressors, refrigerant condensers, condenser fans and motors, and factory supplied...
DOE Office of Scientific and Technical Information (OSTI.GOV)
P. Arnold, Lutz Decker, D. Howe, J. Urbin, Jonathan Homan, Carl Reis, J. Creel, V. Ganni, P. Knudsen, A. Sidi-Yekhlef
The James Webb Telescope is the successor to the Hubble Telescope and will be placed in an orbit of 1.5 million km from earth. Before launch in 2014, the telescope will be tested in NASA Johnson Space Center's (JSC) space simulation chamber, Chamber A. The tests will be conducted at deep space conditions. Chamber A's helium cryo-panels are currently cooled down to 20 K by two Linde 3.5 kW helium refrigerators. The new 12.5 kW, 20-K helium coldbox described in this paper is part of the upgrade to the chamber systems for this large test program. The Linde coldbox willmore » provide refrigeration in several operating modes where the temperature of the chamber is being controlled with a high accuracy due to the demanding NASA test requirements. The implementation of two parallel expansion turbine strings and the Ganni cycle—Floating Pressure process results in a highly efficient and flexible process that minimizes the electrical input power. This paper will describe the collaboration and execution of the coldbox project.« less
NASA Astrophysics Data System (ADS)
Luo, K.; Sun, D. M.; Zhang, J.; Shen, Q.; Zhang, N.
2017-12-01
This study proposes a multi-stage travelling-wave thermoacoustically refrigeration system (TAD-RS) operating at liquefied natural gas temperature, which consists of two thermoacoustic engines (TAE) and one thermoacoustic refrigerator (TAR) in a closed-loop configuration. Three thermoacoustic units connect each other through a resonance tube of small cross-sectional area, achieving “self-matching” for efficient thermoacoustic conversion. Based on the linear thermoacoustic theory, a model of the proposed system has been built by using DeltaEC program to show the acoustic field characteristics and performance. It is shown that with pressurized 5 MPa helium as working gas, the TAEs are able to build a stable and strong acoustic field with a frequency of about 85 Hz. When hot end temperature reaches 923 K, this system can provide about 1410 W cooling power at 110 K with an overall exergy efficiency of 15.5%. This study indicates a great application prospect of TAD-RS in the field of natural gas liquefaction with a large cooling capacity and simple structure.
REACH. Teacher's Guide, Volume I. Secondary Program Management.
ERIC Educational Resources Information Center
Morris, James Lee; And Others
Designed for use with individualized instructional units (CE 026 345 and CE 026 348-350) in the REACH (Refrigeration, Electro-Mechanical, Air-Conditioning, Heating) electromechanical cluster, this secondary teacher's guide is devoted to the establishment of standard instructional procedures. Following an introductory section, sections provide…
The Telecommunications and Data Acquisition Report
NASA Technical Reports Server (NTRS)
Posner, E. C. (Editor)
1987-01-01
Developments in programs managed by the Jet Propulsion Laboratory's Office of Telecommunications and Data Acquisition are discussed. Topics discussed include sorption compression/mechanical expanded hybrid refrigeration, calculated 70-meter antenna performance for offset L-band, systolic arrays and stack decoding, and calibrations of Deep Space Network antennas.
Self-actuating heat switches for redundant refrigeration systems
NASA Technical Reports Server (NTRS)
Chan, Chung K. (Inventor)
1988-01-01
A dual refrigeration system for cooling a sink device is described, which automatically thermally couples the cold refrigerator to the sink device while thermally isolating the warm refrigerator from the sink device. The system includes two gas gap heat switches that each thermally couples one of the refrigerators to the sink device, and a pair of sorption pumps that are coupled through tubes to the heat switches. When the first refrigerator is operated and therefore cold, the first pump which is thermally coupled to it is also cooled and adsorbs gas to withdraw it from the second heat switch, to thereby thermally isolate the sink device from the warm second refrigerator. With the second refrigerator being warm, the second pump is also warm and desorbs gas, so the gas lies in the first switch, to close that switch and therefore thermally couple the cold first refrigerator to the sink device. Thus, the heat switches are automatically switched according to the temperature of the corresponding refrigerator.
High Efficiency, Low Emission Refrigeration System
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fricke, Brian A.; Sharma, Vishaldeep
Supermarket refrigeration systems account for approximately 50% of supermarket energy use, placing this class of equipment among the highest energy consumers in the commercial building domain. In addition, the commonly used refrigeration system in supermarket applications is the multiplex direct expansion (DX) system, which is prone to refrigerant leaks due to its long lengths of refrigerant piping. This leakage reduces the efficiency of the system and increases the impact of the system on the environment. The high Global Warming Potential (GWP) of the hydrofluorocarbon (HFC) refrigerants commonly used in these systems, coupled with the large refrigerant charge and the highmore » refrigerant leakage rates leads to significant direct emissions of greenhouse gases into the atmosphere. Methods for reducing refrigerant leakage and energy consumption are available, but underutilized. Further work needs to be done to reduce costs of advanced system designs to improve market utilization. In addition, refrigeration system retrofits that result in reduced energy consumption are needed since the majority of applications address retrofits rather than new stores. The retrofit market is also of most concern since it involves large-volume refrigerant systems with high leak rates. Finally, alternative refrigerants for new and retrofit applications are needed to reduce emissions and reduce the impact on the environment. The objective of this Collaborative Research and Development Agreement (CRADA) between the Oak Ridge National Laboratory and Hill Phoenix is to develop a supermarket refrigeration system that reduces greenhouse gas emissions and has 25 to 30 percent lower energy consumption than existing systems. The outcomes of this project will include the design of a low emission, high efficiency commercial refrigeration system suitable for use in current U.S. supermarkets. In addition, a prototype low emission, high efficiency supermarket refrigeration system will be produced for laboratory and field testing. Laboratory and field testing will demonstrate the high energy efficiency and low environmental impact of the refrigeration system developed in this project.« less
7 CFR 3300.37 - Testing of a mechanical refrigerating appliance.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 7 Agriculture 15 2010-01-01 2010-01-01 false Testing of a mechanical refrigerating appliance. 3300... SPECIAL EQUIPMENT Procedures for Separate Testing of Mechanical Refrigerating Appliances § 3300.37 Testing of a mechanical refrigerating appliance. For separate testing of a mechanical refrigerating appliance...
46 CFR 151.40-11 - Refrigeration systems.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 5 2010-10-01 2010-10-01 false Refrigeration systems. 151.40-11 Section 151.40-11... Refrigeration systems. (a) Boiloff systems. The venting of cargo boiloff to atmosphere shall not be used as a...) Vapor compression, tank refrigeration, and secondary refrigeration systems: The required cooling...
46 CFR 154.1720 - Indirect refrigeration.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 5 2010-10-01 2010-10-01 false Indirect refrigeration. 154.1720 Section 154.1720... § 154.1720 Indirect refrigeration. A refrigeration system that is used to cool acetaldehyde, ethylene oxide, or methyl bromide, must be an indirect refrigeration system that does not use vapor compression. ...
46 CFR 151.40-11 - Refrigeration systems.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 5 2012-10-01 2012-10-01 false Refrigeration systems. 151.40-11 Section 151.40-11... Refrigeration systems. (a) Boiloff systems. The venting of cargo boiloff to atmosphere shall not be used as a...) Vapor compression, tank refrigeration, and secondary refrigeration systems: The required cooling...
46 CFR 154.1720 - Indirect refrigeration.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 5 2011-10-01 2011-10-01 false Indirect refrigeration. 154.1720 Section 154.1720... § 154.1720 Indirect refrigeration. A refrigeration system that is used to cool acetaldehyde, ethylene oxide, or methyl bromide, must be an indirect refrigeration system that does not use vapor compression. ...
46 CFR 151.40-11 - Refrigeration systems.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 5 2011-10-01 2011-10-01 false Refrigeration systems. 151.40-11 Section 151.40-11... Refrigeration systems. (a) Boiloff systems. The venting of cargo boiloff to atmosphere shall not be used as a...) Vapor compression, tank refrigeration, and secondary refrigeration systems: The required cooling...
46 CFR 154.1720 - Indirect refrigeration.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 5 2012-10-01 2012-10-01 false Indirect refrigeration. 154.1720 Section 154.1720... § 154.1720 Indirect refrigeration. A refrigeration system that is used to cool acetaldehyde, ethylene oxide, or methyl bromide, must be an indirect refrigeration system that does not use vapor compression. ...
46 CFR 154.1720 - Indirect refrigeration.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 5 2014-10-01 2014-10-01 false Indirect refrigeration. 154.1720 Section 154.1720... § 154.1720 Indirect refrigeration. A refrigeration system that is used to cool acetaldehyde, ethylene oxide, or methyl bromide, must be an indirect refrigeration system that does not use vapor compression. ...
46 CFR 151.40-11 - Refrigeration systems.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 5 2014-10-01 2014-10-01 false Refrigeration systems. 151.40-11 Section 151.40-11... Refrigeration systems. (a) Boiloff systems. The venting of cargo boiloff to atmosphere shall not be used as a...) Vapor compression, tank refrigeration, and secondary refrigeration systems: The required cooling...
46 CFR 154.1720 - Indirect refrigeration.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 5 2013-10-01 2013-10-01 false Indirect refrigeration. 154.1720 Section 154.1720... § 154.1720 Indirect refrigeration. A refrigeration system that is used to cool acetaldehyde, ethylene oxide, or methyl bromide, must be an indirect refrigeration system that does not use vapor compression. ...
46 CFR 151.40-11 - Refrigeration systems.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 5 2013-10-01 2013-10-01 false Refrigeration systems. 151.40-11 Section 151.40-11... Refrigeration systems. (a) Boiloff systems. The venting of cargo boiloff to atmosphere shall not be used as a...) Vapor compression, tank refrigeration, and secondary refrigeration systems: The required cooling...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Biancardi, F.R.; Michels, H.H.; Sienel, T.H.
1996-10-01
The purpose of this program was to conduct experimental and analytical efforts to determine lubricant circulation characteristics of new HFC/POE pairs and HFC/mineral oil pairs in a representative central residential HVAC system and to compare their behavior with the traditional HCFC-22/mineral oil (refrigerant/lubricant) pair. A dynamic test facility was designed and built to conduct the experimental efforts. This facility provided a unique capability to visually and physically measure oil circulation rates, on-line, in operating systems. A unique on-line ultraviolet-based measurement device was used to obtain detailed data on the rate and level of lubricant oil circulated within the operating heatmore » pump system. The experimental and analytical data developed during the program are presented as a function of vapor velocity, refrigerant/lubricant viscosity, system features and equipment. Both visual observations and instrumentation were used to understand ``worst case`` oil circulation situations. This report is presented in two volumes. Volume 1 contains a complete description of the program scope, objective, test results summary, conclusions, description of test facility and recommendations for future effort. Volume 2 contains all of the program test data essentially as taken from the laboratory dynamic test facility during the sequence of runs.« less
Federal Register 2010, 2011, 2012, 2013, 2014
2011-04-06
... used as refrigerants during the service, maintenance, repair, or disposal of refrigeration and air... person in the course of maintaining, servicing, repairing, or disposing of refrigeration or air...-depleting refrigerants recovered during the servicing and disposal of air-conditioning and refrigeration...
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 5 2010-10-01 2010-10-01 false Refrigerants. 147.90 Section 147.90 Shipping COAST GUARD... Special Requirements for Particular Materials § 147.90 Refrigerants. (a) Only refrigerants listed in ANSI/ASHRAE 34-78 may be carried as ships' stores. (b) Refrigerants contained in a vessel's operating system...
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 5 2011-10-01 2011-10-01 false Refrigerants. 147.90 Section 147.90 Shipping COAST GUARD... Special Requirements for Particular Materials § 147.90 Refrigerants. (a) Only refrigerants listed in ANSI/ASHRAE 34-78 may be carried as ships' stores. (b) Refrigerants contained in a vessel's operating system...
Health effects among refrigeration repair workers exposed to fluorocarbons.
Campbell, D D; Lockey, J E; Petajan, J; Gunter, B J; Rom, W N
1986-01-01
Refrigeration repair workers may be intermittently exposed to fluorocarbons and their thermal decomposition products. A case of peripheral neuropathy (distal axonopathy) in a commercial refrigeration repairman prompted an epidemiological investigation of the health of refrigeration repair workers. No additional cases of peripheral neuropathy were identified among the 27 refrigeration repair workers studied. A reference group of 14 non-refrigeration repair workers was also studied. No differences were noted between groups for the ulnar (motor and sensory), median (motor and sensory), peroneal, sural, or tibial nerve conduction velocities. Refrigeration repair workers reported palpitations and lightheadedness significantly more often than workers in the reference group. No clinical neurological or electroneurophysiological abnormalities were detected in eight refrigeration repair workers followed up for three years during continuous employment. PMID:3004555
Automotive absorption air conditioner utilizing solar and motor waste heat
NASA Technical Reports Server (NTRS)
Popinski, Z. (Inventor)
1981-01-01
In combination with the ground vehicles powered by a waste heat generating electric motor, a cooling system including a generator for driving off refrigerant vapor from a strong refrigerant absorbant solution is described. A solar collector, an air-cooled condenser connected with the generator for converting the refrigerant vapor to its liquid state, an air cooled evaporator connected with the condenser for returning the liquid refrigerant to its vapor state, and an absorber is connected to the generator and to the evaporator for dissolving the refrigerant vapor in the weak refrigerant absorbant solution, for providing a strong refrigerant solution. A pump is used to establish a pressurized flow of strong refrigerant absorbant solution from the absorber through the electric motor, and to the collector.
Ecker, Amir L.; Pietsch, Joseph A.
1982-01-01
What is disclosed is a heat pump apparatus for conditioning a fluid characterized by a fluid handler and path for circulating the fluid in heat exchange relationship with a refrigerant fluid; at least two refrigerant heat exchangers, one for effecting heat exchange with the fluid and a second for effecting heat exchange between refrigerant and a heat exchange fluid and the ambient air; a compressor for efficiently compressing the refrigerant; at least one throttling valve for throttling liquid refrigerant; a refrigerant circuit; refrigerant; a source of heat exchange fluid; heat exchange fluid circulating device and heat exchange fluid circuit for circulating the heat exchange fluid in heat exchange relationship with the refrigerant; and valves or switches for selecting the heat exchangers and direction of flow of the refrigerant therethrough for selecting a particular mode of operation. The heat exchange fluid provides energy for defrosting the second heat exchanger when operating in the air source mode and also provides a alternate source of heat.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fricke, Brian A; Abdelaziz, Omar; Vineyard, Edward Allan
In this paper, Life Cycle Climate Performance (LCCP) analysis is used to estimate lifetime direct and indirect carbon dioxide equivalent gas emissions of various refrigerant options and commercial refrigeration system designs, including the multiplex DX system with various hydrofluorocarbon (HFC) refrigerants, the HFC/R744 cascade system incorporating a medium-temperature R744 secondary loop, and the transcritical R744 booster system. The results of the LCCP analysis are presented, including the direct and indirect carbon dioxide equivalent emissions for each refrigeration system and refrigerant option. Based on the results of the LCCP analysis, recommendations are given for the selection of low GWP replacement refrigerantsmore » for use in existing commercial refrigeration systems, as well as for the selection of commercial refrigeration system designs with low carbon dioxide equivalent emissions, suitable for new installations.« less
Refrigeration system having dual suction port compressor
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wu, Guolian
A cooling system for appliances, air conditioners, and other spaces includes a compressor, and a condenser that receives refrigerant from the compressor. The system also includes an evaporator that receives refrigerant from the condenser. Refrigerant received from the condenser flows through an upstream portion of the evaporator. A first portion of the refrigerant flows to the compressor without passing through a downstream portion of the evaporator, and a second portion of the refrigerant from the upstream portion of the condenser flows through the downstream portion of the evaporator after passing through the upstream portion of the evaporator. The second portionmore » of the refrigerant flows to the compressor after passing through the downstream portion of the evaporator. The refrigeration system may be configured to cool an appliance such as a refrigerator and/or freezer, or it may be utilized in air conditioners for buildings, motor vehicles, or other such spaces.« less
NASA Astrophysics Data System (ADS)
Komatsubara, Takeo; Sunaga, Takasi; Takahasi, Yasuki
R134a was selected as the alternative refrigerant for R12 because of the similar thermodynamic properties with R12. But refrigeration oil for R12 couldn't be used for R134a because of the immiscibility with R134a. To solve this problem we researched miscible oil with R134a and selected polyol ester oil (POE) as refrigeration oil. But we found sludge deposition into capillary tube after life test of refrigerator with POE and detected metal soap, decomposed oil and alkaline ions by analysis of sludge. This results was proof of phenomena like oil degradation, precipitation of process materials and wear of compressor. Therefore we improved stability and lubricity of POE, reevaluated process materials and contaminations in refrigerating circuit. In this paper we discuss newly developed these technologies and evaluation results of it by life test of refrigerator.
NASA Astrophysics Data System (ADS)
Endoh, Kazuhiro; Matsushima, Hiroaki; Nonaka, Masayuki
HFC zeotropic refrigerant mixture R-407C is one of the promising alternatives for HCFC-22. We have found that the coefficient of performance (COP) of the refrigeration cycle using R-407C is improved by installing a temperature glide shift heat exchanger (TGSX) which takes advantage of zeotropic characteristics to an air-conditioner. We obtained the characteristics of a refrigeration cycle of experimental apparatus with comparison to those of a fundamental refrigeration cycle based on the refrigerant thermodynamic properties. We concluded that the COP improvement ratio of experimental apparatus with the TGSX to that without the TGSX is greater than that ratio which is calculated from the fundamental refrigeration cycle. This proved to be caused by the pressure loss of low pressure side which is not taken into account in the fundamental refrigeration cycle.
Solar Energy Installers Curriculum Guides. Book I.
ERIC Educational Resources Information Center
Walker, Gene C.
This first volume of a comprehensive curriculum guide for the heating-ventilation-air conditioning-refrigeration-solar student is designed to assist high school area vocational centers or community college instructors in the implementation and operation of comfort training programs. Following an introductory section, the guide provides job…
ERIC Educational Resources Information Center
Strang, Lynn; Todd, CeCe
2013-01-01
This article presents trends in the heating, ventilation, air conditioning and refrigeration (HVAC/R) industry, with an emphasis on the importance of technician training programs as exemplified at the East Valley Institute of Technology (EVIT) in Mesa, Arizona. The article states that HVAC workers are increasingly helping their consumers "go…
40 CFR 86.1866-12 - CO2 fleet average credit programs.
Code of Federal Regulations, 2012 CFR
2012-07-01
... technologies designed to reduce air conditioning refrigerant leakage over the useful life of their passenger....1865-12 by implementing specific air conditioning system technologies designed to reduce air... performance improvement for the system of greater than 10% when compared to previous industry standard designs...
40 CFR Appendix A to Subpart F of... - Specifications for Fluorocarbon and Other Refrigerants
Code of Federal Regulations, 2011 CFR
2011-07-01
... Fluorocarbon and Other Refrigerants This appendix is based on the Air-Conditioning and Refrigeration Institute... existing refrigeration and air-conditioning products as required under 40 CFR part 82. 1.1.1Intent. This...-Conditioning and Refrigeration Institute. Appendix C to ARI Standard 700-1995 is incorporated by reference...
40 CFR Appendix A to Subpart F of... - Specifications for Fluorocarbon and Other Refrigerants
Code of Federal Regulations, 2012 CFR
2012-07-01
... Fluorocarbon and Other Refrigerants This appendix is based on the Air-Conditioning and Refrigeration Institute... existing refrigeration and air-conditioning products as required under 40 CFR part 82. 1.1.1Intent. This...-Conditioning and Refrigeration Institute. Appendix C to ARI Standard 700-1995 is incorporated by reference...
40 CFR Appendix A to Subpart F of... - Specifications for Fluorocarbon and Other Refrigerants
Code of Federal Regulations, 2013 CFR
2013-07-01
... Fluorocarbon and Other Refrigerants This appendix is based on the Air-Conditioning and Refrigeration Institute... existing refrigeration and air-conditioning products as required under 40 CFR part 82. 1.1.1Intent. This...-Conditioning and Refrigeration Institute. Appendix C to ARI Standard 700-1995 is incorporated by reference...
40 CFR Appendix A to Subpart F of... - Specifications for Fluorocarbon and Other Refrigerants
Code of Federal Regulations, 2010 CFR
2010-07-01
... Fluorocarbon and Other Refrigerants This appendix is based on the Air-Conditioning and Refrigeration Institute... existing refrigeration and air-conditioning products as required under 40 CFR part 82. 1.1.1Intent. This...-Conditioning and Refrigeration Institute. Appendix C to ARI Standard 700-1995 is incorporated by reference...
40 CFR Appendix A to Subpart F of... - Specifications for Fluorocarbon and Other Refrigerants
Code of Federal Regulations, 2014 CFR
2014-07-01
... Fluorocarbon and Other Refrigerants This appendix is based on the Air-Conditioning and Refrigeration Institute... existing refrigeration and air-conditioning products as required under 40 CFR part 82. 1.1.1Intent. This...-Conditioning and Refrigeration Institute. Appendix C to ARI Standard 700-1995 is incorporated by reference...
The paper discusses a refrigerator/freezer (RF) system that has two complete and independent refrigeration cycles for the two compartments. It uses a non-azeotropic refrigerant mixture (NARM) in each cycle and countercurrent heat exchangers throughout. This RF is housed in a stan...
Code of Federal Regulations, 2010 CFR
2010-01-01
... consumption of commercial refrigerators, freezers, and refrigerator-freezers. 431.64 Section 431.64 Energy... method for the measurement of energy consumption of commercial refrigerators, freezers, and refrigerator... energy consumption in kilowatt hours per day (kWh/day) for a given product category and volume or total...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Calm, J.M.
1997-02-01
The Refrigerant Database is an information system on alternative refrigerants, associated lubricants, and their use in air conditioning and refrigeration. It consolidates and facilitates access to property, compatibility, environmental, safety, application and other information. It provides corresponding information on older refrigerants, to assist manufacturers and those using alterative refrigerants, to make comparisons and determine differences. The underlying purpose is to accelerate phase out of chemical compounds of environmental concern. The database provides bibliographic citations and abstracts for publications that may be useful in research and design of air-conditioning and refrigeration equipment. The complete documents are not included, though some maymore » be added at a later date. The database identifies sources of specific information on various refrigerants. It addresses lubricants including alkylbenzene, polyalkylene glycol, polyolester, and other synthetics as well as mineral oils. It also references documents addressing compatibility of refrigerants and lubricants with metals, plastics, elastomers, motor insulation, and other materials used in refrigerant circuits. Incomplete citations or abstracts are provided for some documents. They are included to accelerate availability of the information and will be completed or replaced in future updates.« less
Properties of Gas Mixtures and Their Use in Mixed-Refrigerant Joule-Thomson Refrigerators
NASA Astrophysics Data System (ADS)
Luo, E.; Gong, M.; Wu, J.; Zhou, Y.
2004-06-01
The Joule-Thomson (J-T) effect has been widely used for achieving low temperatures. In the past few years, much progress has been made in better understanding the working mechanism of the refrigeration method and in developing prototypes for different applications. In this talk, there are three aspects of our research work to be discussed. First, some special thermal properties of the mixtures for achieving liquid nitrogen temperature range will be presented. Secondly, some important conclusions from the optimization of various mixed-refrigerant J-T cycles such as a simple J-T cycle and an auto-cascade mixed-refrigerant J-T cycle will be presented. Moreover, an auto-cascade, mixed-refrigerant J-T refrigerator with a special mixture capable of achieving about 50K will be mentioned. Finally, various prototypes based on the mixed-refrigerant refrigeration technology will be described. These applications include miniature J-T cryocoolers for cooling infrared detectors and high-temperature superconducting devices, cryosurgical knife for medical treatment, low-temperature refrigerators for biological storage and so forth. The on-going research work and unanswered questions for this technology will be also discussed.
NASA Astrophysics Data System (ADS)
Tan, Yingying; Chen, Youming; Wang, Lin
2018-06-01
A mixed refrigerant ejector refrigeration cycle operating with two-stage vapor-liquid separators (MRERC2) is proposed to obtain refrigeration temperature at -40°C. The thermodynamic investigations on performance of MRERC2 using zeotropic mixture refrigerant R23/R134a are performed, and the comparisons of cycle performance between MRERC2 and MRERC1 (MRERC with one-stage vapor-liquid separator) are conducted. The results show that MRERC2 can achieve refrigeration temperature varying between -23.9°C and -42.0°C when ejector pressure ratio ranges from 1.6 to 2.3 at the generation temperature of 57.3-84.9°C. The parametric analysis indicates that increasing condensing temperature decreases coefficient of performance ( COP) of MRERC2, and increasing ejector pressure ratio and mass fraction of the low boiling point component in the mixed refrigerant can improve COP of MRERC2. The MRERC2 shows its potential in utilizing low grade thermal energy as driving power to obtain low refrigeration temperature for the ejector refrigeration cycle.
Assi, Tina-Marie; Rajgopal, Jayant; Norman, Bryan A.; Chen, Sheng-I; Brown, Shawn T.; Slayton, Rachel B.; Kone, Souleymane; Kenea, Hailu; Welling, Joel S.; Connor, Diana L.; Wateska, Angela R.; Jana, Anirban; Wiringa, Ann E.; Van Panhuis, Willem G.; Burke, Donald S.
2012-01-01
Objectives. We investigated whether introducing the rotavirus and pneumococcal vaccines, which are greatly needed in West Africa, would overwhelm existing supply chains (i.e., the series of steps required to get a vaccine from the manufacturers to the target population) in Niger. Methods. As part of the Bill and Melinda Gates Foundation–funded Vaccine Modeling Initiative, we developed a computational model to determine the impact of introducing these new vaccines to Niger's Expanded Program on Immunization vaccine supply chain. Results. Introducing either the rotavirus vaccine or the 7-valent pneumococcal conjugate vaccine could overwhelm available storage and transport refrigerator space, creating bottlenecks that would prevent the flow of vaccines down to the clinics. As a result, the availability of all World Health Organization Expanded Program on Immunization vaccines to patients might decrease from an average of 69% to 28.2% (range = 10%–51%). Addition of refrigerator and transport capacity could alleviate this bottleneck. Conclusions. Our results suggest that the effects on the vaccine supply chain should be considered when introducing a new vaccine and that computational models can help assess evolving needs and prevent problems with vaccine delivery. PMID:21940923
Two-statge sorption type cryogenic refrigerator including heat regeneration system
NASA Technical Reports Server (NTRS)
Jones, Jack A. (Inventor); Wen, Liang-Chi (Inventor); Bard, Steven (Inventor)
1989-01-01
A lower stage chemisorption refrigeration system physically and functionally coupled to an upper stage physical adsorption refrigeration system. Waste heat generated by the lower stage cycle is regenerated to fuel the upper stage cycle thereby greatly improving the energy efficiency of a two-stage sorption refrigerator. The two stages are joined by disposing a first pressurization chamber providing a high pressure flow of a first refrigerant for the lower stage refrigeration cycle within a second pressurization chamber providing a high pressure flow of a second refrigerant for the upper stage refrigeration cycle. The first pressurization chamber is separated from the second pressurization chamber by a gas-gap thermal switch which at times is filled with a thermoconductive fluid to allow conduction of heat from the first pressurization chamber to the second pressurization chamber.
Low cost microminiature refrigerators for large unit volume applications
NASA Technical Reports Server (NTRS)
Duboc, R. M., Jr.
1983-01-01
Photolithographic techniques were employed to fabricate small Joule-Thomson refrigerators in laminated substrates. The gas passages of a J-T refrigerator are formed by etching channels as narrow as 50 microns and as shallow as 5 microns in glass plates which are laminated together. Circular refrigerators on the order of 1.5 centimeters in diameter and .75 millimeters thick were produced which cool down to cryogenic temperatures in a few seconds, using Argon or Nitrogen, with no vacuum or radiation insulation. Smaller refrigerators are developed for both faster cooldown and low refrigeration capacity applications. By using this technology, custom refrigerators can be designed to meet specific application requirements.
NASA Astrophysics Data System (ADS)
Hu, Yong; Li, Zongbin; Yang, Bo; Qian, Suxin; Gan, Weimin; Gong, Yuanyuan; Li, Yang; Zhao, Dewei; Liu, Jian; Zhao, Xiang; Zuo, Liang; Wang, Dunhui; Du, Youwei
2017-04-01
Solid-state refrigeration based on the caloric effects is promising to replace the traditional vapor-compressing refrigeration technology due to environmental protection and high efficiency. However, the narrow working temperature region has hindered the application of these refrigeration technologies. In this paper, we propose a method of combined caloric, through which a broad refrigeration region can be realized in a multiferroic alloy, Ni-Mn-Ga, by combining its elastocaloric and magnetocaloric effects. Moreover, the materials' efficiency of elastocaloric effect has been greatly improved in our sample. These results illuminate a promising way to use multiferroic alloys for refrigeration with a broad refrigeration temperature region.
Chen, Wenchun; Druzak, Samuel A; Wang, Yingchun; Josephson, Cassandra D; Hoffmeister, Karin M; Ware, Jerry; Li, Renhao
2017-12-01
Apheresis platelets for transfusion treatment are currently stored at room temperature because after refrigeration platelets are rapidly cleared on transfusion. In this study, the role of von Willebrand factor (VWF) in the clearance of refrigerated platelets is addressed. Human and murine platelets were refrigerated in gas-permeable bags at 4°C for 24 hours. VWF binding, platelet signaling events, and platelet post-transfusion recovery and survival were measured. After refrigeration, the binding of plasma VWF to platelets was drastically increased, confirming earlier studies. The binding was blocked by peptide OS1 that bound specifically to platelet glycoprotein (GP)Ibα and was absent in VWF - / - plasma. Although surface expression of GPIbα was reduced after refrigeration, refrigeration-induced VWF binding under physiological shear induced unfolding of the GPIbα mechanosensory domain on the platelet, as evidenced by increased exposure of a linear epitope therein. Refrigeration and shear treatment also induced small elevation of intracellular Ca 2+ , phosphatidylserine exposure, and desialylation of platelets, which were absent in VWF -/- platelets or inhibited by OS1, which is a monomeric 11-residue peptide (CTERMALHNLC). Furthermore, refrigerated VWF -/- platelets displayed increased post-transfusion recovery and survival than wild-type ones. Similarly, adding OS1 to transgenic murine platelets expressing only human GPIbα during refrigeration improved their post-transfusion recovery and survival. Refrigeration-induced binding of VWF to platelets facilitates their rapid clearance by inducing GPIbα-mediated signaling. Our results suggest that inhibition of the VWF-GPIbα interaction may be a potential strategy to enable refrigeration of platelets for transfusion treatment. © 2017 American Heart Association, Inc.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gaul, Chris; Sheppy, Michael
This study describes the test results of a Refrigerant Pump System integrated into a commercial supermarket direct expansion (DX) vapor compression refrigeration system. The Liquid Refrigerant Pump System retrofit (patent-pending; application number 13/964,198) was introduced to NREL in August 2014 by CTA Architects Engineers.
Heat pump with freeze-up prevention
Ecker, Amir L.
1981-01-01
What is disclosed is a heat pump apparatus for conditioning a fluid characterized by a fluid handler and path for circulating the fluid in heat exchange relationship with a refrigerant fluid; at least two refrigerant heat exchangers, one for effecting heat exchange with the fluid and a second for effecting heat exchange between refrigerant and a heat exchange fluid and the ambient air; a compressor for efficiently compressing the refrigerant; at least one throttling valve for throttling liquid refrigerant; a refrigerant circuit; refrigerant; a source of heat exchange fluid; heat exchange fluid circulating device and heat exchange fluid circuit for circulating the heat exchange fluid in heat exchange relationship with the refrigerant; and valves or switches for selecting the heat exchangers and direction of flow of the refrigerant therethrough for selecting a particular mode of operation. The heat exchange fluid prevents freeze up of the second heat exchanger by keeping the temperature above the dew point; and, optionally, provides heat for efficient operation.
NASA Technical Reports Server (NTRS)
Westra, Douglas G.
1993-01-01
With the February, 1992 announcement by President Bush to move the deadline for outlawing CFC (chloro-fluoro-carbon) refrigerants from the year 2000 to the year 1996, the refrigeration and air-conditioning industries have been accelerating their efforts to find alternative refrigerants. Many of the alternative refrigerants being evaluated require synthetic lubricants, are less efficient, and have toxicity problems. One option to developing new, alternative refrigerants is to combine existing non-CFC refrigerants to form a nonazeotropic mixture, with the concentration optimized for the given application so that system COP (Coefficient Of Performance) may be maintained or even improved. This paper will discuss the dilemma that industry is facing regarding CFC phase-out and the problems associated with CFC alternatives presently under development. A definition of nonazeotropic mixtures will be provided, and the characteristics and COP benefits of nonazeotropic refrigerant mixtures will be explained using thermodynamic principles. Limitations and disadvantages of nonazeotropic mixtures will be discussed, and example systems using such mixtures will be reviewed.
THERMODYNAMIC PROPERTIES OF SELECTED HFC REFRIGERANTS
Hydrofluorocarbon (HFC) refrigerants are possible alternatives to replace ozone-depleting chlorofluorocarbon and hydrochlorofluorocarbon (HCFC) refrigerants. The flammability of a proposed new refrigerant is a major consideration in assessing its utility for a particular applicat...
46 CFR 195.30-1 - Application.
Code of Federal Regulations, 2011 CFR
2011-10-01
... equipped with any refrigeration unit using— (1) Ammonia to refrigerate any space with a volume of more than... is equipped with any refrigeration unit using— (1) Ammonia to refrigerate any space with a volume of...
46 CFR 195.30-1 - Application.
Code of Federal Regulations, 2012 CFR
2012-10-01
... equipped with any refrigeration unit using— (1) Ammonia to refrigerate any space with a volume of more than... is equipped with any refrigeration unit using— (1) Ammonia to refrigerate any space with a volume of...
46 CFR 195.30-1 - Application.
Code of Federal Regulations, 2014 CFR
2014-10-01
... equipped with any refrigeration unit using— (1) Ammonia to refrigerate any space with a volume of more than... is equipped with any refrigeration unit using— (1) Ammonia to refrigerate any space with a volume of...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-02-23
... trigger rates for comfort cooling, commercial refrigeration, and industrial process refrigeration and air..., commercial refrigeration, and industrial process refrigeration appliances. This action also proposes to...
46 CFR 195.30-1 - Application.
Code of Federal Regulations, 2013 CFR
2013-10-01
... equipped with any refrigeration unit using— (1) Ammonia to refrigerate any space with a volume of more than... is equipped with any refrigeration unit using— (1) Ammonia to refrigerate any space with a volume of...
46 CFR 195.30-1 - Application.
Code of Federal Regulations, 2010 CFR
2010-10-01
... equipped with any refrigeration unit using— (1) Ammonia to refrigerate any space with a volume of more than... is equipped with any refrigeration unit using— (1) Ammonia to refrigerate any space with a volume of...
Dilution cycle control for an absorption refrigeration system
Reimann, Robert C.
1984-01-01
A dilution cycle control system for an absorption refrigeration system is disclosed. The control system includes a time delay relay for sensing shutdown of the absorption refrigeration system and for generating a control signal only after expiration of a preselected time period measured from the sensed shutdown of the absorption refrigeration system, during which the absorption refrigeration system is not restarted. A dilution cycle for the absorption refrigeration system is initiated in response to generation of a control signal by the time delay relay. This control system is particularly suitable for use with an absorption refrigeration system which is frequently cycled on and off since the time delay provided by the control system prevents needless dilution of the absorption refrigeration system when the system is turned off for only a short period of time and then is turned back on.
Two stage sorption type cryogenic refrigerator including heat regeneration system
NASA Technical Reports Server (NTRS)
Jones, Jack A. (Inventor); Wen, Liang-Chi (Inventor); Bard, Steven (Inventor)
1989-01-01
A lower stage chemisorption refrigeration system physically and functionally coupled to an upper stage physical adsorption refrigeration system is disclosed. Waste heat generated by the lower stage cycle is regenerated to fuel the upper stage cycle thereby greatly improving the energy efficiency of a two-stage sorption refrigerator. The two stages are joined by disposing a first pressurization chamber providing a high pressure flow of a first refrigerant for the lower stage refrigeration cycle within a second pressurization chamber providing a high pressure flow of a second refrigerant for the upper stage refrigeration cycle. The first pressurization chamber is separated from the second pressurization chamber by a gas-gap thermal switch which at times is filled with a thermoconductive fluid to allow conduction of heat from the first pressurization chamber to the second pressurization chamber.
REACH. Teacher's Guide, Volume I. Post-Secondary Program Management.
ERIC Educational Resources Information Center
Morris, James Lee; And Others
Designed for use with individualized instruction units (CE 026 345-347, and CE 026 349-351) in the REACH (Refrigeration, Electro-Mechanical, Air-Conditioning, Heating) electromechanical cluster, this first volume of the postsecondary teacher's guide is devoted to the establishment of standard instructional procedures. Following an introductory…
ERIC Educational Resources Information Center
Dunn, James A.; And Others
This report provides vocational teachers with readability information for selected vocational texts. Selected texts are categorized and appear in charts according to 21 vocational programs: accounting, air conditioning and refrigeration, automotive shop (automotive body and fender repair, automotive mechanics), aviation shop, business, carpentry,…
Federal Register 2010, 2011, 2012, 2013, 2014
2013-07-10
.... Incomplete Cycling 6. Mechanical Temperature Controls 7. Ambient Temperature Gradient 8. Definitions.... at 29846-29847. A broad group of stakeholders \\1\\ submitted a joint comment supporting DOE's proposal... for variable defrost control (a control type in which the time interval between successive defrost...
Solar Energy Installers Curriculum Guides. Book II.
ERIC Educational Resources Information Center
Walker, Gene C.
This second volume of a comprehensive curriculum guide for the heating-ventilation-air conditioning-refrigeration-solar student is designed to assist high school area vocational centers or community college instructors in the implementation and operation of comfort training programs. The guide is comprised of ten units of instruction within three…
U. S. Navy’s Superconductivity Programs; Scientific Curosity To Fleet Utility
2010-10-01
NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) 5d. PROJECT NUMBER 5e. TASK NUMBER 5f. WORK UNIT NUMBER 7. PERFORMING ORGANIZATION NAME(S) AND...ADDRESS(ES) Naval Research Laboratory,Washington,DC,20375 8. PERFORMING ORGANIZATION REPORT NUMBER 9. SPONSORING/MONITORING AGENCY NAME(S) AND ADDRESS...classes of materials studied for superconductivity were ternary alloys13, and organic materials14. The dilution refrigerator largely replaced
ARTI refrigerant database. Quarterly report, March--May 1997
DOE Office of Scientific and Technical Information (OSTI.GOV)
Calm, J.M.
1997-05-01
The Refrigerant Database is an information system on alternative refrigerants, associated lubricants, and their use in air conditioning and refrigeration. It consolidates and facilitates access to property, compatibility, environmental, safety, application and other information. It provides corresponding information an older refrigerants, to assist manufacturers and those using alternative refrigerants, to make comparisons and determine differences. The underlying purpose is to accelerate phase out of chemical compounds of environmental concern. The database provides bibliographic citations and abstracts for publications that may be useful in research and design of air-conditioning and refrigeration equipment. The complete documents are not included, though some maymore » be added at a later date.« less
Method of reducing chlorofluorocarbon refrigerant emissons to the atmosphere
DeVault, Robert C.; Fairchild, Phillip D.; Biermann, Wendell J.
1990-01-01
A method is disclosed for reducing chloroflurocarbon (CFC) refrigerant emissions during removal or transfer or refrigerants from a vapor compression cooling system or heat pump which comprises contacting the refrigerant with a suitable sorbent material. The sorbent material allows for the storage and retention or the chlorofluorocarbon in non-gaseous form so that it does not tend to escape to the atmosphere where it would cause harm by contributing to ozone depletion. In other aspects of the invention, contacting of CFC refrigerants with sorbent material allows for purification and recycling of used refrigerant, and a device containing stored sorbent material can be employed in the detection of refrigerant leakage in a cooling system or heat pump.
Mei, Viung C.; Chen, Fang C.
1997-01-01
A refrigeration system having a vapor compression cycle utilizing a liquid over-feeding operation with an integrated accumulator-expander-heat exchanger. Hot, high-pressure liquid refrigerant from the condenser passes through one or more lengths of capillary tubing substantially immersed in a pool liquid refrigerant in the accumulator-expander-heat exchanger for simultaneously sub-cooling and expanding the liquid refrigerant while vaporizing liquid refrigerant from the pool for the return thereof to the compressor as saturated vapor. The sub-cooling of the expanded liquid provides for the flow of liquid refrigerant into the evaporator for liquid over-feeding the evaporator and thereby increasing the efficiency of the evaporation cycle.
Mei, V.C.; Chen, F.C.
1997-04-22
A refrigeration system is described having a vapor compression cycle utilizing a liquid over-feeding operation with an integrated accumulator-expander-heat exchanger. Hot, high-pressure liquid refrigerant from the condenser passes through one or more lengths of capillary tubing substantially immersed in a pool liquid refrigerant in the accumulator-expander-heat exchanger for simultaneously sub-cooling and expanding the liquid refrigerant while vaporizing liquid refrigerant from the pool for the return thereof to the compressor as saturated vapor. The sub-cooling of the expanded liquid provides for the flow of liquid refrigerant into the evaporator for liquid over-feeding the evaporator and thereby increasing the efficiency of the evaporation cycle. 4 figs.
Method of removing an immiscible lubricant from a refrigeration system and apparatus for same
Spauschus, Hans O.; Starr, Thomas L.
1999-01-01
A method of separating an immiscible lubricant from a liquid refrigerant in a refrigerating system including a compressor, a condenser, an expansion device and an evaporator, wherein the expansion device is connected to the condenser by a liquid refrigerant flow line for liquid refrigerant and immiscible lubricant. The method comprising slowing the rate of flow of the liquid refrigerant and immiscible lubricant between the condenser and the expansion device such that the liquid refrigerant and the immiscible lubricant separate based upon differences in density. The method also comprises collecting the separated immiscible lubricant in a collection chamber in fluid communication with the separated immiscible lubricant. Apparatus for performing the method is also disclosed.
Not all counterclockwise thermodynamic cycles are refrigerators
NASA Astrophysics Data System (ADS)
Dickerson, R. H.; Mottmann, J.
2016-06-01
Clockwise cycles on PV diagrams always represent heat engines. It is therefore tempting to assume that counterclockwise cycles always represent refrigerators. This common assumption is incorrect: most counterclockwise cycles cannot be refrigerators. This surprising result is explored here for quasi-static ideal gas cycles, and the necessary conditions for refrigeration cycles are clarified. Three logically self-consistent criteria can be used to determine if a counterclockwise cycle is a refrigerator. The most fundamental test compares the counterclockwise cycle with a correctly determined corresponding Carnot cycle. Other criteria we employ include a widely accepted description of the functional behavior of refrigerators, and a corollary to the second law that limits a refrigerator's coefficient of performance.
Measurement of the Space Thermoacoustic Refrigerator Performance
1990-09-01
the refrigerator was a requisite towards simplifying the process of selecting the operating frequency . The simplest method allowing for the most...LIST OF FIGURES I-1 Pulse Tube Refrigerator.............................. 3 1-2 Hofler Refrigerator.................................. 5 1-3 Acoustical...qualitative manner as did Rayleigh. The first example of an acoustic heat pump was the pulse - tube refrigerator in which Gifford and Longsworth, by applying
DOE Office of Scientific and Technical Information (OSTI.GOV)
Calm, J.M.
The Refrigerant Database is an information system on alternative refrigerants, associated lubricants, and their use in air conditioning and refrigeration. It consolidates and facilities access to property, compatibility, environmental, safety, application and other information. It provides corresponding information on older refrigerants, to assist manufacturers and those using alternative refrigerants, to make comparisons and determine differences. The underlying purpose is to accelerate phase out of chemical compounds of environmental concern.
Ecker, Amir L.
1980-01-01
What is disclosed is a heat exchanger-accumulator for vaporizing a refrigerant or the like, characterized by an upright pressure vessel having a top, bottom and side walls; an inlet conduit eccentrically and sealingly penetrating through the top; a tubular overflow chamber disposed within the vessel and sealingly connected with the bottom so as to define an annular outer volumetric chamber for receiving refrigerant; a heat transfer coil disposed in the outer volumetric chamber for vaporizing the liquid refrigerant that accumulates there; the heat transfer coil defining a passageway for circulating an externally supplied heat exchange fluid; transferring heat efficiently from the fluid; and freely allowing vaporized refrigerant to escape upwardly from the liquid refrigerant; and a refrigerant discharge conduit penetrating sealingly through the top and traversing substantially the length of the pressurized vessel downwardly and upwardly such that its inlet is near the top of the pressurized vessel so as to provide a means for transporting refrigerant vapor from the vessel. The refrigerant discharge conduit has metering orifices, or passageways, penetrating laterally through its walls near the bottom, communicating respectively interiorly and exteriorly of the overflow chamber for controllably carrying small amounts of liquid refrigerant and oil to the effluent stream of refrigerant gas.
46 CFR 130.230 - Protection from refrigerants.
Code of Federal Regulations, 2014 CFR
2014-10-01
... refrigerants. (a) For each refrigeration system that exceeds 0.6 cubic meters (20 cubic feet) of storage... refrigeration equipment. (c) A complete recharge in the form of a spare charge must be carried for each self...
Code of Federal Regulations, 2011 CFR
2011-10-01
... equipped with any refrigeration unit using— (1) Ammonia to refrigerate any space with a volume of more than... equipped with any refrigeration unit using— (1) Ammonia to refrigerate any space with a volume of more than...
46 CFR 130.230 - Protection from refrigerants.
Code of Federal Regulations, 2011 CFR
2011-10-01
... refrigerants. (a) For each refrigeration system that exceeds 0.6 cubic meters (20 cubic feet) of storage... refrigeration equipment. (c) A complete recharge in the form of a spare charge must be carried for each self...
Code of Federal Regulations, 2013 CFR
2013-10-01
... equipped with any refrigeration unit using— (1) Ammonia to refrigerate any space with a volume of more than... equipped with any refrigeration unit using— (1) Ammonia to refrigerate any space with a volume of more than...
Code of Federal Regulations, 2012 CFR
2012-10-01
... equipped with any refrigeration unit using— (1) Ammonia to refrigerate any space with a volume of more than... equipped with any refrigeration unit using— (1) Ammonia to refrigerate any space with a volume of more than...
46 CFR 130.230 - Protection from refrigerants.
Code of Federal Regulations, 2013 CFR
2013-10-01
... refrigerants. (a) For each refrigeration system that exceeds 0.6 cubic meters (20 cubic feet) of storage... refrigeration equipment. (c) A complete recharge in the form of a spare charge must be carried for each self...
Code of Federal Regulations, 2014 CFR
2014-10-01
... equipped with any refrigeration unit using— (1) Ammonia to refrigerate any space with a volume of more than... equipped with any refrigeration unit using— (1) Ammonia to refrigerate any space with a volume of more than...
46 CFR 130.230 - Protection from refrigerants.
Code of Federal Regulations, 2012 CFR
2012-10-01
... refrigerants. (a) For each refrigeration system that exceeds 0.6 cubic meters (20 cubic feet) of storage... refrigeration equipment. (c) A complete recharge in the form of a spare charge must be carried for each self...
Code of Federal Regulations, 2010 CFR
2010-10-01
... equipped with any refrigeration unit using— (1) Ammonia to refrigerate any space with a volume of more than... equipped with any refrigeration unit using— (1) Ammonia to refrigerate any space with a volume of more than...
46 CFR 130.230 - Protection from refrigerants.
Code of Federal Regulations, 2010 CFR
2010-10-01
... refrigerants. (a) For each refrigeration system that exceeds 0.6 cubic meters (20 cubic feet) of storage... refrigeration equipment. (c) A complete recharge in the form of a spare charge must be carried for each self...
10 CFR 431.62 - Definitions concerning commercial refrigerators, freezers and refrigerator-freezers.
Code of Federal Regulations, 2010 CFR
2010-01-01
... functional characteristics that affect energy consumption. Commercial refrigerator, freezer, and refrigerator... formed by the plane of the door, when the equipment is viewed in cross-section; and (2) For equipment...
Magnetic refrigeration using flux compression in superconductors
NASA Technical Reports Server (NTRS)
Israelsson, U. E.; Strayer, D. M.; Jackson, H. W.; Petrac, D.
1990-01-01
The feasibility of using flux compression in high-temperature superconductors to produce the large time-varying magnetic fields required in a field cycled magnetic refrigerator operating between 20 K and 4 K is presently investigated. This paper describes the refrigerator concept and lists limitations and advantages in comparison with conventional refrigeration techniques. The maximum fields obtainable by flux compression in high-temperature supercoductor materials, as presently prepared, are too low to serve in such a refrigerator. However, reports exist of critical current values that are near usable levels for flux pumps in refrigerator applications.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hessell, Edward Thomas
The goal of this project is to develop and test new synthetic lubricants that possess high compatibility with new low ozone depleting (LOD) and low global warming potential (LGWP) refrigerants and offer improved lubricity and wear protection over current lubricant technologies. The improved compatibility of the lubricants with the refrigerants, along with improved lubricating properties, will resulted in lower energy consumption and longer service life of the refrigeration systems used in residential, commercial and industrial heating, ventilating and air-conditioning (HVAC) and refrigeration equipment.
Dilution refrigeration for space applications
NASA Technical Reports Server (NTRS)
Israelsson, U. E.; Petrac, D.
1990-01-01
Dilution refrigerators are presently used routinely in ground based applications where temperatures below 0.3 K are required. The operation of a conventional dilution refrigerator depends critically on the presence of gravity. To operate a dilution refrigerator in space many technical difficulties must be overcome. Some of the anticipated difficulties are identified in this paper and possible solutions are described. A single cycle refrigerator is described conceptually that uses forces other than gravity to function and the stringent constraints imposed on the design by requiring the refrigerator to function on the earth without using gravity are elaborated upon.
The 1- to 4-K refrigeration techniques for cooling masers on a beam waveguide antenna
NASA Technical Reports Server (NTRS)
Johnson, D. L.
1986-01-01
The status of technology is reported for various 1- to 4-K commercially available refrigeration systems capable of producing 1.5-K refrigeration to cool masers and superconducting cavity oscillators on the proposed beam waveguide antenna. The design requirements for the refrigeration system and the cryostat are presented. A continuously operating evaporation refrigerator that uses capillary tubing to provide a continuous, self-regulating flow of helium at approximately 1.5 K has been selected as the first refrigerator design for the beam waveguide antenna.
NASA Astrophysics Data System (ADS)
Deymi-Dashtebayaz, Mahdi; Farahnak, Mehdi; Moraffa, Mojtaba; Ghalami, Arash; Mohammadi, Nima
2018-03-01
In this paper the effects of refrigerant charge amount and ambient air temperature on performance and thermodynamic condition of refrigerating cycle in the split type air-conditioner have been investigated. Optimum mass charge is the point at which the energy efficiency ratio (EER) of refrigeration cycle becomes the maximum. Experiments have been conducted over a range of refrigerant mass charge from 540 to 840 g and a range of ambient temperature from 27 to 45 °C, in a 12,000 Btu/h split air-conditioner as case study. The various parameters have been considered to evaluate the cooling rate, energy efficiency ratio (EER), mass charge effect and thermodynamic cycle of refrigeration system with R22 refrigerant gas. Results confirmed that the lack of appropriate refrigerant mass charge causes the refrigeration system not to reach its maximum cooling capacity. The highest cooling capacity achieved was 3.2 kW (11,000 Btu/h). The optimum mass charge and corresponding EER of studied system have been obtained about 640 g and 2.5, respectively. Also, it is observed that EER decreases by 30% as ambient temperature increases from 27 °C to 45 °C. By optimization of the refrigerant mass charge in refrigerating systems, about 785 GWh per year of electric energy can be saved in Iran's residential sector.
Method and apparatus for desuperheating refrigerant
Zess, James A.; Drost, M. Kevin; Call, Charles J.
1997-01-01
The present invention is an apparatus and method for de-superheating a primary refrigerant leaving a compressor wherein a secondary refrigerant is used between the primary refrigerant to be de-superheated. Reject heat is advantageously used for heat reclaim.
ALTERNATIVE TECHNOLOGIES FOR REFRIGERATION AND AIR-CONDITIONING APPLICATIONS
The report gives results of an assessment of refrigeration technologies that are alternatives to vapor compression refrigeration for use in five application categories: domestic air conditioning, commercial air conditioning, mobile air conditioning, domestic refrigeration, and co...
Cooling system having dual suction port compressor
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wu, Guolian
2017-08-29
A cooling system for appliances, air conditioners, and other spaces includes a compressor, and a condenser that receives refrigerant from the compressor. The system also includes an evaporator that receives refrigerant from the condenser. Refrigerant received from the condenser flows through an upstream portion of the evaporator. A first portion of the refrigerant flows to the compressor without passing through a downstream portion of the evaporator, and a second portion of the refrigerant from the upstream portion of the condenser flows through the downstream portion of the evaporator after passing through the upstream portion of the evaporator. The second portionmore » of the refrigerant flows to the compressor after passing through the downstream portion of the evaporator. The refrigeration system may be configured to cool an appliance such as a refrigerator and/or freezer, or it may be utilized in air conditioners for buildings, motor vehicles, or other such spaces.« less
Ecker, Amir L.
1983-01-01
A heat pump apparatus for conditioning a fluid characterized by a fluid handler and path for circulating a fluid in heat exchange relationship with a refrigerant fluid, at least three refrigerant heat exchangers, one for effecting heat exchange with the fluid, a second for effecting heat exchange with a heat exchange fluid, and a third for effecting heat exchange with ambient air; a compressor for compressing the refrigerant; at least one throttling valve connected at the inlet side of a heat exchanger in which liquid refrigerant is vaporized; a refrigerant circuit; refrigerant; a source of heat exchange fluid; heat exchange fluid circuit and pump for circulating the heat exchange fluid in heat exchange relationship with the refrigerant; and valves or switches for selecting the heat exchangers and directional flow of refrigerant therethrough for selecting a particular mode of operation. Also disclosed are a variety of embodiments, modes of operation, and schematics therefor.
Analysis of DC control in double-inlet GM type pulse tube refrigerators for detectors
NASA Astrophysics Data System (ADS)
Du, B. Y.
2016-10-01
Pulse tube refrigerators have demonstrated many advantages with respect to temperature stability, vibration, reliability and lifetime among cryo-coolers for detectors. Double-inlet type pulse tube refrigerators are popular in GM type pulse tube refrigerators. The single double-inlet valve may introduce DC flow in refrigerator, which deteriorates the performance of pulse tube refrigerator. One new type of DC control mode is introduced in this paper. Two parallel-placed needle valves with opposite direction named double-valve configuration, instead of single double-inlet valve, are used in our experiment to reduce the DC flow. With two double-inlet operating, the lowest cold end temperature of 18.1K and a coolant of 1.2W@20K have been obtained. It has proved that this method is useful for controlling DC flow of the pulse tube refrigerators, which is very important to understand the characters of pulse tube refrigerators for detectors.
Method of removing an immiscible lubricant from a refrigeration system and apparatus for same
Spauschus, H.O.; Starr, T.L.
1999-03-30
A method is described for separating an immiscible lubricant from a liquid refrigerant in a refrigerating system including a compressor, a condenser, an expansion device and an evaporator, wherein the expansion device is connected to the condenser by a liquid refrigerant flow line for liquid refrigerant and immiscible lubricant. The method comprising slowing the rate of flow of the liquid refrigerant and immiscible lubricant between the condenser and the expansion device such that the liquid refrigerant and the immiscible lubricant separate based upon differences in density. The method also comprises collecting the separated immiscible lubricant in a collection chamber in fluid communication with the separated immiscible lubricant. Apparatus for performing the method is also disclosed. 3 figs.
Cummins, Niamh Maria; Hannigan, Ailish; Shannon, Bill; Dunne, Colum; Cullen, Walter
2013-01-01
Background The Internet is a widely used source of information for patients searching for medical/health care information. While many studies have assessed existing medical/health care information on the Internet, relatively few have examined methods for design and delivery of such websites, particularly those aimed at the general public. Objective This study describes a method of evaluating material for new medical/health care websites, or for assessing those already in existence, which is correlated with higher rankings on Google's Search Engine Results Pages (SERPs). Methods A website quality assessment (WQA) tool was developed using criteria related to the quality of the information to be contained in the website in addition to an assessment of the readability of the text. This was retrospectively applied to assess existing websites that provide information about generic medicines. The reproducibility of the WQA tool and its predictive validity were assessed in this study. Results The WQA tool demonstrated very high reproducibility (intraclass correlation coefficient=0.95) between 2 independent users. A moderate to strong correlation was found between WQA scores and rankings on Google SERPs. Analogous correlations were seen between rankings and readability of websites as determined by Flesch Reading Ease and Flesch-Kincaid Grade Level scores. Conclusions The use of the WQA tool developed in this study is recommended as part of the design phase of a medical or health care information provision website, along with assessment of readability of the material to be used. This may ensure that the website performs better on Google searches. The tool can also be used retrospectively to make improvements to existing websites, thus, potentially enabling better Google search result positions without incurring the costs associated with Search Engine Optimization (SEO) professionals or paid promotion. PMID:23981848
Experimental investigation of an alternating evaporator duty refrigerator/freezer
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lavanis, M.; Haider, I.; Radermacher, R.
1998-12-31
A bistable solenoid valve has been used to build an alternating evaporator duty (AED) domestic refrigerator/freezer. This refrigerator has two vapor compression refrigeration loops that share a common compressor, condenser, and suction line heat exchanger. Each of the refrigeration loops has an expansion device and evaporator. One evaporator is located in the fresh food compartment and the other is located in the freezer compartment. The bistable solenoid valve directs the flow of the refrigerant through one loop at a time. Only one of the two compartments is cooled at any given time. With this configuration, the food compartment is cooledmore » at a higher evaporator temperature than the freezer. Due to this, the energy efficiency of the refrigerator is improved by 8.5% over a conventional domestic refrigerator/freezer. Also, this cycle allows for completely independent temperature control of the freezer and fresh food compartments. There may be a penalty because this cycle does not allow for both loops to be simultaneously optimized. Isobutane was the only refrigerant used in this investigation.« less
Method and apparatus for de-superheating refrigerant
Zess, J.A.; Drost, M.K.; Call, C.J.
1997-11-25
The present invention is an apparatus and method for de-superheating a primary refrigerant leaving a compressor wherein a secondary refrigerant is used between the primary refrigerant to be de-superheated. Reject heat is advantageously used for heat reclaim. 7 figs.
Discussion of Refrigeration Cycle Using Carbon Dioxide as Refrigerant
NASA Astrophysics Data System (ADS)
Ji, Amin; Sun, Miming; Li, Jie; Yin, Gang; Cheng, Keyong; Zhen, Bing; Sun, Ying
Nowadays, the problem of the environment goes worse, it urges people to research and study new energy-saving and environment-friendly refrigerants, such as carbon dioxide, at present, people do research on carbon dioxide at home and abroad. This paper introduces the property of carbon dioxide as a refrigerant, sums up and analyses carbon dioxide refrigeration cycles, and points out the development and research direction in the future.
Liquid over-feeding air conditioning system and method
Mei, Viung C.; Chen, Fang C.
1993-01-01
A refrigeration air conditioning system utilizing a liquid over-feeding operation is described. A liquid refrigerant accumulator-heat exchanger is placed in the system to provide a heat exchange relationship between hot liquid refrigerant discharged from condenser and a relatively cool mixture of liquid and vaporous refrigerant discharged from the evaporator. This heat exchange relationship substantially sub-cools the hot liquid refrigerant which undergoes little or no evaporation across the expansion device and provides a liquid over-feeding operation through the evaporator for effectively using 100 percent of evaporator for cooling purposes and for providing the aforementioned mixture of liquid and vaporous refrigerant.
NASA Astrophysics Data System (ADS)
Veera Raghavalu, K.; Govindha Rasu, N.
2018-03-01
The present research paper focuses on the use of Nano additive refrigerants in vapor compression refrigeration system (VCRS) because of their amazing development during Thermo Physical along with heat transfer potential to improve the coefficient of performance (COP) and reliability of refrigeration system. Furthermore, challenges and future instructions of performance enhancement of VCRS using Nano additive refrigerants were presented. Lubricant oil is essential in the entire vapour compression refrigeration systems, mostly for the efficient function of the compressor. But, some assign of the oil is entire the cycle oil circulates with the refrigerant. Presently, an assortment of investigation is going on in the field of the Nano-particles like metals, oxides, carbon Nano-tubes or carbides. Nano-lubricants are unique type of Nano-fluids which are varieties of Nano-particles, lubricants and have a wide variety in the fields of refrigeration systems. This paper, has been done on the application of Nano-particles balanced in lubricating oils of refrigerating systems are reviewed. The aim of this investigation is to study and find which type of lubricant oil works better with Nano-particles in the area of refrigeration. From the review of literature, it has been observed that Nano-particles mixed with mineral oil gives enhanced results than polyolester (POE) oil.
Evaluation of Enthalpy Diagrams for NH3-H2O Absorption Refrigerator
NASA Astrophysics Data System (ADS)
Takei, Toshitaka; Saito, Kiyoshi; Kawai, Sunao
The protection of environment is becoming a grave problem nowadays and an absorption refrigerator, which does not use fleon as a refrigerant, is acquiring a close attention. Among the absorption refrigerators, a number of ammonia-water absorption refrigerators are being used in realm such as refrigeration and ice accumulation, since this type of refrigerator can produce below zero degree products. It is essential to conduct an investigation on the characteristics of ammonia-water absorption refrigerator in detail by means of computer simulation in order to realize low cost, highly efficient operation. Unfortunately, there have been number of problems in order to conduct computer simulations. Firstly, Merkel's achievements of enthalpy diagram does not give the relational equations. And secondly, although relational equation are being proposed by Ziegler, simpler equations that can be applied to computer simulation are yet to be proposed. In this research, simper equations based on Ziegler's equations have been derived to make computer simulation concerning the performance of ammonia-water absorption refrigerator possible-Both results of computer simulations using simple equations and Merkel's enthalpy diagram respectively, have been compared with the actual experimental data of one staged ammonia-water absorption refrigerator. Consequently, it is clarified that the results from Ziegler's equations agree with experimental data better than those from Merkel's enthalpy diagram.
Review of magnetic refrigeration system as alternative to conventional refrigeration system
NASA Astrophysics Data System (ADS)
Mezaal, N. A.; Osintsev, K. V.; Zhirgalova, T. B.
2017-10-01
The refrigeration system is one of the most important systems in industry. Developers are constantly seeking for how to avoid the damage to the environment. Magnetic refrigeration is an emerging, environment-friendly technology based on a magnetic solid that acts as a refrigerant by magneto-caloric effect (MCE). In the case of ferromagnetic materials, MCE warms as the magnetic moments of the atom are aligned by the application of a magnetic field. There are two types of magnetic phase changes that may occur at the Curie point: first order magnetic transition (FOMT) and second order magnetic transition (SOMT). The reference cycle for magnetic refrigeration is AMR (Active Magnetic Regenerative cycle), where the magnetic material matrix works both as a refrigerating medium and as a heat regenerating medium, while the fluid flowing in the porous matrix works as a heat transfer medium. Regeneration can be accomplished by blowing a heat transfer fluid in a reciprocating fashion through the regenerator made of magnetocaloric material that is alternately magnetized and demagnetized. Many magnetic refrigeration prototypes with different designs and software models have been built in different parts of the world. In this paper, the authors try to shed light on the magnetic refrigeration and show its effectiveness compared with conventional refrigeration methods.
Flight equipment supporting metabolic experiments on SLS-1
NASA Technical Reports Server (NTRS)
Leach, Carolyn S.; Inners, L. D.
1991-01-01
Five experiments in different aspects of human metabolism will be performed on Spacelab Life Sciences-1. Nine items of equipment from the Life Sciences Laboratory Equipment inventory will be used: the rack-mounted centrifuge, the hematocrit centrifuge, the low-gravity centrifuge, a body-mass measurement device, a urine monitoring system, the Spacelab refrigerator/freezer, the Orbiter refrigerator, an in-flight blood collection system, and a pocket voice recorder. In addition, each experiment will require some specialized equipment such as incubators and culture blocks for an immunology experiment, and tracers for a fluid and electrolyte experiment and a hematology experiment. The equipment for these experiments has been developed over many years, in some cases since the Skylab program in the early 1970s, and has been certified for use on the Space Shuttle.
Cryogenics for the MuCool Test Area (MTA)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Darve, Christine; Norris, Barry; Pei, Liu-Jin
2005-09-01
MuCool Test Area (MTA) is a complex of buildings at Fermi National Accelerator Laboratory, which are dedicated to operate components of a cooling cell to be used for Muon Collider and Neutrino Factory R&D. The long-term goal of this facility is to test ionization cooling principles by operating a 25-liter liquid hydrogen (LH{sub 2}) absorber embedded in a 5 Tesla superconducting solenoid magnet. The MTA solenoid magnet will be used with RF cavities exposed to a high intensity beam. Cryogens used at the MTA include LHe, LN{sub 2} and LH{sub 2}. The latter dictates stringent system design for hazardous locations.more » The cryogenic plant is a modified Tevatron refrigerator based on the Claude cycle. The implementation of an in-house refrigerator system and two 300 kilowatt screw compressors is under development. The helium refrigeration capacity is 500 W at 14 K. In addition the MTA solenoid magnet will be batch-filled with LHe every 2 days using the same cryo-plant. This paper reviews cryogenic systems used to support the Muon Collider and Neutrino Factory R&D programs and emphasizes the feasibility of handling cryogenic equipment at MTA in a safe manner.« less
Cryogenics for the MuCool Test Area (MTA)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Darve, Christine; Norris, Barry; Pei, Liujin
2006-03-20
MuCool Test Area (MTA) is a complex of buildings at Fermi National Accelerator Laboratory, which are dedicated to operate components of a cooling cell to be used for Muon Collider and Neutrino Factory R and D. The long-term goal of this facility is to test ionization cooling principles by operating a 25-liter liquid hydrogen (LH2) absorber embedded in a 5 Tesla superconducting solenoid magnet. The MTA solenoid magnet will be used with RF cavities exposed to a high intensity beam. Cryogens used at the MTA include LHe, LN2 and LH2. The latter dictates stringent system design for hazardous locations. Themore » cryogenic plant is a modified Tevatron refrigerator based on the Claude cycle. The implementation of an in-house refrigerator system and two 300 kilowatt screw compressors is under development. The helium refrigeration capacity is 500 W at 14 K. In addition the MTA solenoid magnet will be batch-filled with LHe every 2 days using the same cryo-plant. This paper reviews cryogenic systems used to support the Muon Collider and Neutrino Factory R and D programs and emphasizes the feasibility of handling cryogenic equipment at MTA in a safe manner.« less
Solar Absorption Refrigeration System for Air-Conditioning of a Classroom Building in Northern India
NASA Astrophysics Data System (ADS)
Agrawal, Tanmay; Varun; Kumar, Anoop
2015-10-01
Air-conditioning is a basic tool to provide human thermal comfort in a building space. The primary aim of the present work is to design an air-conditioning system based on vapour absorption cycle that utilizes a renewable energy source for its operation. The building under consideration is a classroom of dimensions 18.5 m × 13 m × 4.5 m located in Hamirpur district of Himachal Pradesh in India. For this purpose, cooling load of the building was calculated first by using cooling load temperature difference method to estimate cooling capacity of the air-conditioning system. Coefficient of performance of the refrigeration system was computed for various values of strong and weak solution concentration. In this work, a solar collector is also designed to provide required amount of heat energy by the absorption system. This heat energy is taken from solar energy which makes this system eco-friendly and sustainable. A computer program was written in MATLAB to calculate the design parameters. Results were obtained for various values of solution concentrations throughout the year. Cost analysis has also been carried out to compare absorption refrigeration system with conventional vapour compression cycle based air-conditioners.
This procedure describes the calibration and maintenance activities of a refrigerator custodian in ensuring that refrigerators and freezers are functioning within acceptable temperature ranges. Refrigerators and freezers were used as temperature-controlled repositories for reagen...
Code of Federal Regulations, 2013 CFR
2013-07-01
... vehicle air conditioners means mechanical vapor compression refrigeration equipment used to cool the... the hermetically sealed refrigeration systems used on motor vehicles for refrigerated cargo and the...-conditioning and Refrigeration Institute (ARI 700-93) (which is codified at 40 CFR part 82, subpart F, appendix...
Code of Federal Regulations, 2014 CFR
2014-07-01
... vehicle air conditioners means mechanical vapor compression refrigeration equipment used to cool the... the hermetically sealed refrigeration systems used on motor vehicles for refrigerated cargo and the...-conditioning and Refrigeration Institute (ARI 700-93) (which is codified at 40 CFR part 82, subpart F, appendix...
Code of Federal Regulations, 2011 CFR
2011-07-01
... vehicle air conditioners means mechanical vapor compression refrigeration equipment used to cool the... the hermetically sealed refrigeration systems used on motor vehicles for refrigerated cargo and the...-conditioning and Refrigeration Institute (ARI 700-93) (which is codified at 40 CFR part 82, subpart F, appendix...
Code of Federal Regulations, 2010 CFR
2010-07-01
... vehicle air conditioners means mechanical vapor compression refrigeration equipment used to cool the... the hermetically sealed refrigeration systems used on motor vehicles for refrigerated cargo and the...-conditioning and Refrigeration Institute (ARI 700-93) (which is codified at 40 CFR part 82, subpart F, appendix...
46 CFR 154.702 - Refrigerated carriage.
Code of Federal Regulations, 2013 CFR
2013-10-01
... FOR SELF-PROPELLED VESSELS CARRYING BULK LIQUEFIED GASES Design, Construction and Equipment Cargo Pressure and Temperature Control § 154.702 Refrigerated carriage. (a) Each refrigeration system must: (1... the purpose of this section, a “refrigeration unit” includes a compressor and its motors and controls...
46 CFR 154.702 - Refrigerated carriage.
Code of Federal Regulations, 2012 CFR
2012-10-01
... FOR SELF-PROPELLED VESSELS CARRYING BULK LIQUEFIED GASES Design, Construction and Equipment Cargo Pressure and Temperature Control § 154.702 Refrigerated carriage. (a) Each refrigeration system must: (1... the purpose of this section, a “refrigeration unit” includes a compressor and its motors and controls...
46 CFR 154.702 - Refrigerated carriage.
Code of Federal Regulations, 2011 CFR
2011-10-01
... FOR SELF-PROPELLED VESSELS CARRYING BULK LIQUEFIED GASES Design, Construction and Equipment Cargo Pressure and Temperature Control § 154.702 Refrigerated carriage. (a) Each refrigeration system must: (1... the purpose of this section, a “refrigeration unit” includes a compressor and its motors and controls...
46 CFR 154.702 - Refrigerated carriage.
Code of Federal Regulations, 2010 CFR
2010-10-01
... FOR SELF-PROPELLED VESSELS CARRYING BULK LIQUEFIED GASES Design, Construction and Equipment Cargo Pressure and Temperature Control § 154.702 Refrigerated carriage. (a) Each refrigeration system must: (1... the purpose of this section, a “refrigeration unit” includes a compressor and its motors and controls...
46 CFR 154.702 - Refrigerated carriage.
Code of Federal Regulations, 2014 CFR
2014-10-01
... FOR SELF-PROPELLED VESSELS CARRYING BULK LIQUEFIED GASES Design, Construction and Equipment Cargo Pressure and Temperature Control § 154.702 Refrigerated carriage. (a) Each refrigeration system must: (1... the purpose of this section, a “refrigeration unit” includes a compressor and its motors and controls...
Code of Federal Regulations, 2012 CFR
2012-07-01
... Administrator pursuant to § 82.38. (b) Approved refrigerant recycling equipment means equipment certified by the... equipment extracts and recycles refrigerant or extracts refrigerant for recycling on-site or reclamation off... terms of this paragraph (e), approved refrigerant recycling equipment may be transported off-site and...
A general computer model for predicting the performance of gas sorption refrigerators
NASA Technical Reports Server (NTRS)
Sigurdson, K. B.
1983-01-01
Projected performance requirements for cryogenic spacecraft sensor cooling systems which demand higher reliability and longer lifetimes are outlined. The gas/solid sorption refrigerator is viewed as a potential solution to cryogenic cooling needs. A software model of an entire gas sorption refrigerator system was developed. The numerical model, evaluates almost any combination and order of refrigerator components and any sorbent-sorbate pair or which the sorption isotherm data are available. Parametric curves for predicting system performance were generated for two types of refrigerators, a LaNi5-H2 absorption cooler and a Charcoal-N2 adsorption cooler. It is found that precooling temperature and heat exchanger effectiveness affect the refrigerator performance. It is indicated that gas sorption refrigerators are feasible for a number of space applications.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Parker, D.; Sutherland, K.; Chasar, D.
The U.S. Department of Energy (DOE) Building America program, in collaboration with Florida Power and Light (FPL), conducted a phased residential energy-efficiency retrofit program. This research sought to establish impacts on annual energy and peak energy reductions from the technologies applied at two levels of retrofit - shallow and deep, with savings levels approaching the Building America program goals of reducing whole-house energy use by 40%. Under the Phased Deep Retrofit (PDR) project, we have installed phased, energy-efficiency retrofits in a sample of 56 existing, all-electric homes. End-use savings and economic evaluation results from the phased measure packages and singlemore » measures are summarized in this report. Project results will be of interest to utility program designers, weatherization evaluators, and the housing remodel industry. Shallow retrofits were conducted in all homes from March to June 2013. The measures for this phase were chosen based on ease of installation, targeting lighting (CFLs and LED lamps), domestic hot water (wraps and showerheads), refrigeration (cleaning of coils), pool pump (reduction of operating hours), and the home entertainment center (smart plugs). Deep retrofits were conducted on a subset of ten PDR homes from May 2013 through March 2014. Measures included new air source heat pumps, duct repair, ceiling insulation, heat pump water heaters, variable speed pool pumps and learning thermostats. Major appliances such as refrigerators and dishwashers were replaced where they were old and inefficient.« less
Refrigeration system with a compressor-pump unit and a liquid-injection desuperheating line
Gaul, Christopher J.
2001-01-01
The refrigeration system includes a compressor-pump unit and/or a liquid-injection assembly. The refrigeration system is a vapor-compression refrigeration system that includes an expansion device, an evaporator, a compressor, a condenser, and a liquid pump between the condenser and the expansion device. The liquid pump improves efficiency of the refrigeration system by increasing the pressure of, thus subcooling, the liquid refrigerant delivered from the condenser to the expansion device. The liquid pump and the compressor are driven by a single driving device and, in this regard, are coupled to a single shaft of a driving device, such as a belt-drive, an engine, or an electric motor. While the driving device may be separately contained, in a preferred embodiment, the liquid pump, the compressor, and the driving device (i.e., an electric motor) are contained within a single sealable housing having pump and driving device cooling paths to subcool liquid refrigerant discharged from the liquid pump and to control the operating temperature of the driving device. In another aspect of the present invention, a liquid injection assembly is included in a refrigeration system to divert liquid refrigerant from the discharge of a liquid pressure amplification pump to a compressor discharge pathway within a compressor housing to desuperheat refrigerant vapor to the saturation point within the compressor housing. The liquid injection assembly includes a liquid injection pipe with a control valve to meter the volume of diverted liquid refrigerant. The liquid injection assembly may also include a feedback controller with a microprocessor responsive to a pressure sensor and a temperature sensor both positioned between the compressor to operate the control valve to maintain the refrigerant at or near saturation.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Beshr, Mohamed; Aute, Vikrant; Abdelaziz, Omar
Commercial refrigeration systems consumed 1.21 Quads of primary energy in 2010 and are known to be a major source for refrigerant charge leakage into the environment. Thus, it is important to study the environmental impact of commercial supermarket refrigeration systems and improve their design to minimize any adverse impacts. The system s Life Cycle Climate Performance (LCCP) was presented as a comprehensive metric with the aim of calculating the equivalent mass of carbon dioxide released into the atmosphere throughout its lifetime, from construction to operation and destruction. In this paper, an open source tool for the evaluation of the LCCPmore » of different air-conditioning and refrigeration systems is presented and used to compare the environmental impact of a typical multiplex direct expansion (DX) supermarket refrigeration systems based on three different refrigerants as follows: two hydrofluorocarbon (HFC) refrigerants (R-404A, and R-407F), and a low global warming potential (GWP) refrigerant (N-40). The comparison is performed in 8 US cities representing different climates. The hourly energy consumption of the refrigeration system, required for the calculation of the indirect emissions, is calculated using a widely used building energy modeling tool (EnergyPlus). A sensitivity analysis is performed to determine the impact of system charge and power plant emission factor on the LCCP results. Finally, we performed an uncertainty analysis to determine the uncertainty in total emissions for both R-404A and N-40 operated systems. We found that using low GWP refrigerants causes a considerable drop in the impact of uncertainty in the inputs related to direct emissions on the uncertainty of the total emissions of the system.« less
A study of alternative refrigerants for the refrigeration and air conditioning sector in Mauritius
NASA Astrophysics Data System (ADS)
Dreepaul, R. K.
2017-11-01
The most frequently used refrigerants in the refrigeration and air conditioning (RAC) sector in Mauritius are currently hydrochlorofluorocarbons (HCFC) and hydrofluorocarbons (HFC). However, because of their strong influence on global warming and the impact of HCFCs on the ozone layer, refrigerants such as ammonia (NH3), carbon dioxide (CO2) and Hydrocarbons (HC), having minimal impact on the environment, are being considered. So far, HCs have only been safely used in domestic refrigeration. Ammonia has been used mainly for industrial refrigeration whereas CO2 is still under study. In this paper, a comparative study of the various feasible alternatives is presented in a survey that was undertaken with major stake holders in the field. The retrofitting possibility of existing equipment was assessed and safety issues associated with each refrigerant were analysed. The major setback of hydrocarbons as a widely accepted refrigerant is its flammability which was considered as a major safety hazard by the majority of respondents in the survey and the main advantages are the improved equipment coefficient of performance (COP) and better TEWI factor. This resulted in a 12 % drop in energy consumption. Despite the excellent thermodynamic properties of ammonia, its use has mainly been confined to industrial refrigeration due to its toxicity. In Mauritius, the performance of ammonia in air conditioning is being evaluated on a pilot basis. The major setback of carbon dioxide as a refrigerant is the high operating pressure which is considered a safety hazard. The high initial investment cost and the lack of qualified maintenance technician is also an issue. The use of CO2 is mainly being considered in the commercial refrigeration sector.
Refrigeration generation using expander-generator units
NASA Astrophysics Data System (ADS)
Klimenko, A. V.; Agababov, V. S.; Koryagin, A. V.; Baidakova, Yu. O.
2016-05-01
The problems of using the expander-generator unit (EGU) to generate refrigeration, along with electricity were considered. It is shown that, on the level of the temperatures of refrigeration flows using the EGU, one can provide the refrigeration supply of the different consumers: ventilation and air conditioning plants and industrial refrigerators and freezers. The analysis of influence of process parameters on the cooling power of the EGU, which depends on the parameters of the gas expansion process in the expander and temperatures of cooled environment, was carried out. The schematic diagram of refrigeration generation plant based on EGU is presented. The features and advantages of EGU to generate refrigeration compared with thermotransformer of steam compressive and absorption types were shown, namely: there is no need to use the energy generated by burning fuel to operate the EGU; beneficial use of the heat delivered to gas from the flow being cooled in equipment operating on gas; energy production along with refrigeration generation, which makes it possible to create, using EGU, the trigeneration plants without using the energy power equipment. It is shown that the level of the temperatures of refrigeration flows, which can be obtained by using the EGU on existing technological decompression stations of the transported gas, allows providing the refrigeration supply of various consumers. The information that the refrigeration capacity of an expander-generator unit not only depends on the parameters of the process of expansion of gas flowing in the expander (flow rate, temperatures and pressures at the inlet and outlet) but it is also determined by the temperature needed for a consumer and the initial temperature of the flow of the refrigeration-carrier being cooled. The conclusion was made that the expander-generator units can be used to create trigeneration plants both at major power plants and at small energy.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-06-07
... moisture. Haier's technology is similar to that used by General Electric Company (GE), Whirlpool... Group and Haier America Trading, L.L.C. (Haier) a waiver from the DOE electric refrigerator and... that takes this technology into account when measuring energy consumption. DATES: This Decision and...
ERIC Educational Resources Information Center
Missouri Univ., Columbia. Dept. of Practical Arts and Vocational-Technical Education.
This document contains trade and industrial occupations-related materials to help teachers and parents teach access skills to Missouri junior high and high school special needs students who want to pursue a vocational program in carpentry; commercial art; drafting; electronics; heating, air conditioning, and refrigeration; or offset lithography…
A Case for Food Service Companies
ERIC Educational Resources Information Center
Korey, Herbert A.
1973-01-01
In this satellite system, all food is prepared fresh daily in the junior high school and shipped in refrigerated trucks to other school locations. Explains how increasing operational costs forced the Long Branch, New Jersey, School District to seek the aid of a food management company to plan and implement this new program. (Author)
40 CFR 86.1866-12 - CO2 fleet average credit programs.
Code of Federal Regulations, 2010 CFR
2010-07-01
... technologies designed to reduce air conditioning refrigerant leakage over the useful life of their passenger... implementing specific air conditioning system technologies designed to reduce air conditioning-related CO2... than 10% when compared to previous industry standard designs): 1.1 g/mi. (viii) Oil separator: 0.6 g/mi...
40 CFR 86.1866-12 - CO2 fleet average credit programs.
Code of Federal Regulations, 2011 CFR
2011-07-01
... technologies designed to reduce air conditioning refrigerant leakage over the useful life of their passenger... implementing specific air conditioning system technologies designed to reduce air conditioning-related CO2... than 10% when compared to previous industry standard designs): 1.1 g/mi. (viii) Oil separator: 0.6 g/mi...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-04-08
... (``VRF'') multi-split systems. Carrier requests this waiver for the SMMSi systems because the basic design of VRF multi-split systems prevents testing or rating according to DOE's prescribed test... adopted by AHRI--``ANSI/AHRI 1230--2010: Performance Rating of Variable Refrigerant Flow (VRF) Multi-Split...
77 FR 3559 - Energy Conservation Program for Consumer Products: Test Procedures for Refrigerators...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-01-25
..., which is typical of an approach enabled by more sophisticated electronic controls. Id. The interim final... and long- time automatic defrost or variable defrost control and adjust the default values of maximum... accurate measurement of the energy use of products with variable defrost control. DATES: The amendments are...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-08-29
... Freezers AGENCY: Office of Energy Efficiency and Renewable Energy, Department of Energy. ACTION: Extension... INFORMATION CONTACT: Mr. Lucas Adin, U.S. Department of Energy, Office of Energy Efficiency and Renewable... Energy Efficiency, Energy Efficiency and Renewable Energy. [FR Doc. 2013-21115 Filed 8-28-13; 8:45 am...
An Approach to Developing the Laboratory Through Senior Design Projects.
ERIC Educational Resources Information Center
Faghri, Amir
1987-01-01
Describes a program in which senior engineering students are given the opportunity to design, make, and test apparatus intended for an upper-level teaching laboratory. Discusses such projects as a vapor compressor test stand with refrigerant mass flow measurement, a double-walled concentric annular heat pipe, and a vacuum filling station. (TW)
46 CFR 128.410 - Ship's service refrigeration systems.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 4 2014-10-01 2014-10-01 false Ship's service refrigeration systems. 128.410 Section 128.410 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OFFSHORE SUPPLY VESSELS... service refrigeration systems. No self-contained unit either for air-conditioning or for refrigerated...
46 CFR 128.410 - Ship's service refrigeration systems.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 4 2011-10-01 2011-10-01 false Ship's service refrigeration systems. 128.410 Section 128.410 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OFFSHORE SUPPLY VESSELS... service refrigeration systems. No self-contained unit either for air-conditioning or for refrigerated...
46 CFR 128.410 - Ship's service refrigeration systems.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 4 2012-10-01 2012-10-01 false Ship's service refrigeration systems. 128.410 Section 128.410 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OFFSHORE SUPPLY VESSELS... service refrigeration systems. No self-contained unit either for air-conditioning or for refrigerated...
46 CFR 128.410 - Ship's service refrigeration systems.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 4 2010-10-01 2010-10-01 false Ship's service refrigeration systems. 128.410 Section 128.410 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OFFSHORE SUPPLY VESSELS... service refrigeration systems. No self-contained unit either for air-conditioning or for refrigerated...
46 CFR 128.410 - Ship's service refrigeration systems.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 4 2013-10-01 2013-10-01 false Ship's service refrigeration systems. 128.410 Section 128.410 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OFFSHORE SUPPLY VESSELS... service refrigeration systems. No self-contained unit either for air-conditioning or for refrigerated...
Neon turbo-Brayton cycle refrigerator for HTS power machines
NASA Astrophysics Data System (ADS)
Hirai, Hirokazu; Hirokawa, M.; Yoshida, Shigeru; Nara, N.; Ozaki, S.; Hayashi, H.; Okamoto, H.; Shiohara, Y.
2012-06-01
We developed a prototype turbo-Brayton refrigerator whose working fluid is neon gas. The refrigerator is designed for a HTS (High Temperature Superconducting) power transformer and its cooling power is more than 2 kW at 65 K. The refrigerator has a turboexpander and a turbo-compressor, which utilize magnetic bearings. These rotational machines have no rubbing parts and no oil-components. Those make a long maintenance interval of the refrigerator. The refrigerator is very compact because our newly developed turbo-compressor is volumetrically smaller than a displacement type compressor in same operating specification. Another feature of the refrigerator is a wide range operation capability for various heat-loads. Cooling power is controlled by the input-power of the turbo-compressor instead of the conventional method of using an electric heater. The rotational speed of the compressor motor is adjusted by an inverter. This system is expected to be more efficient. We show design details, specification and cooling test results of the new refrigerator in this paper.
Coefficient of performance and its bounds with the figure of merit for a general refrigerator
NASA Astrophysics Data System (ADS)
Long, Rui; Liu, Wei
2015-02-01
A general refrigerator model with non-isothermal processes is studied. The coefficient of performance (COP) and its bounds at maximum χ figure of merit are obtained and analyzed. This model accounts for different heat capacities during the heat transfer processes. So, different kinds of refrigerator cycles can be considered. Under the constant heat capacity condition, the upper bound of the COP is the Curzon-Ahlborn (CA) coefficient of performance and is independent of the time durations of the heat exchanging processes. With the maximum χ criterion, in the refrigerator cycles, such as the reversed Brayton refrigerator cycle, the reversed Otto refrigerator cycle and the reversed Atkinson refrigerator cycle, where the heat capacity in the heat absorbing process is not less than that in the heat releasing process, their COPs are bounded by the CA coefficient of performance; otherwise, such as for the reversed Diesel refrigerator cycle, its COP can exceed the CA coefficient of performance. Furthermore, the general refined upper and lower bounds have been proposed.
Luo, E C; Dai, W; Zhang, Y; Ling, H
2006-12-22
In this paper, a thermally-driven thermoacoustic refrigerator system without any moving part is reported. This refrigeration system consists of a thermoacoustic-Stirling heat engine and a thermoacoustic-Stirling refrigerator; that is, the former is the driving source for the latter. Both the subsystems are designed to operate on traveling-wave mode. In the experiment, it was found that the DC-flows had significant negative effect on the heat engine and the refrigerator. To suppress these DC-flows, two flexible membranes were inserted into the two subsystems and worked very well. Then extensive experiments were made to test the influence of different parameters on refrigeration performance of the whole system. The system has so far achieved a no-load temperature of -65 degrees C, a cooling capacity of about 270 W at -20 degrees C and 405 W at 0 degrees C; in fact, the result showed a good prospect of the refrigeration system in room-temperature cooling such as food refrigeration and air-conditioning.
Liquid over-feeding air conditioning system and method
Mei, V.C.; Chen, F.C.
1993-09-21
A refrigeration air conditioning system utilizing a liquid over-feeding operation is described. A liquid refrigerant accumulator-heat exchanger is placed in the system to provide a heat exchange relationship between hot liquid refrigerant discharged from condenser and a relatively cool mixture of liquid and vaporous refrigerant discharged from the evaporator. This heat exchange relationship substantially sub-cools the hot liquid refrigerant which undergoes little or no evaporation across the expansion device and provides a liquid over-feeding operation through the evaporator for effectively using 100 percent of evaporator for cooling purposes and for providing the aforementioned mixture of liquid and vaporous refrigerant. 1 figure.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Calm, J.M.
The Refrigerant Database is an information system on alternative refrigerants, associated lubricants, and their use in air conditioning and refrigeration. It consolidates and facilitates access to property, compatibility, environmental, safety, application and other information. It provides corresponding information on older refrigerants, to assist manufactures and those using alternative refrigerants, to make comparisons and determine differences. The underlying purpose is to accelerate phase out of chemical compounds of environmental concern. The database provides bibliographic citations and abstracts for publications that may be useful in research and design of air-conditioning and refrigeration equipment. The complete documents are not included, though some maymore » be added at a later date. The database identifies sources of specific information on many refrigerants including propane, ammonia, water, carbon dioxide, propylene, ethers, and others as well as azeotropic and zeotropic blends of these fluids. It addresses lubricants including alkylbenzene, polyalkylene glycol, polyolester, and other synthetics as well as mineral oils. It also references documents addressing compatibility of refrigerants and lubricants with metals, plastics, elastomers, motor insulation, and other materials used in refrigerant circuits. Incomplete citations or abstracts are provided for some documents. They are included to accelerate availability of the information and will be completed or replaced in future updates.« less
Redesign 3 R Machine as a Refrigerant Waste Treatment Alternative in Environmental Rescue
NASA Astrophysics Data System (ADS)
Negara, I. P. S.; Arsawan, I. M.
2018-01-01
Cooling machine technologies really affect nowadays’ modern life, not only limited in enhancement of life quality and comfort, but it has also reached the essential things of humans’ life supporter (Arora, 2001). Cooling machine technologies have direct contribution toward environmental damage such as depletion of ozone layer and global warming through synthetic refrigerant waste and leakage (CFC and HFC) to environment. The refrigerant release to the environment is 60% of the service sector. Destructive characteristics of ozone possessed by CFC were first proposed by Rowland and Molina which were then supported by yard measurement. It is estimated that ozone layer damage occurs for about 3% every decade. The ozone layer located in the stratosphere is functioned to prevent ultraviolet-B ray from entering into earth surface. This Ultraviolet-B is suspected to be the cause of health problem for humans and disorder for plants on earth. As for the purpose of this research is to obtain a product design of refrigerant waste processing system (recovery and recycle refrigerant) as well as to acknowledge the work method (COP) of cooling machines that use CFC refrigerant (R-12) as the result of recovery and recycle compared to CFC refrigerant (R-12)/pure R134a. One method that can be used is by redesigning existing equipment namely 3R machine that cannot be used anymore thus it can be reused. This research will be conducted through modifying the existing 3R machine therefore it can be reused and be easily operated as well as doing the maintenance, after that the refrigerant as the result of recovery will be tried on a refrigeration system and a test of refrigeration system work method will be conducted by using the refrigerant recycle product which is obtained and compared with the work method of the one with pure refrigeration.The result has been achieved that the redesign product of refrigerant waste processing equipment can be reused and able to perform the recovery, recycle and richarging process, although using semi-automatic control system. So the use of car air conditioning refrigerant can be more efficient. With the functioning of 3R mesi is expected wastes refrigerant is not wasted which is one of the efforts to save the environment.
10 CFR 431.62 - Definitions concerning commercial refrigerators, freezers and refrigerator-freezers.
Code of Federal Regulations, 2011 CFR
2011-01-01
...-section. Basic model means, with respect to commercial refrigerators, freezers, and refrigerator-freezers... 430); (2) Is not designed and marketed exclusively for medical, scientific, or research purposes; (3... standard product temperature-measuring device. Vertical Closed means equipment with hinged or sliding doors...
SIMULATION RESULTS OF SINGLE REFRIGERANTS FOR USE IN A DUAL-CIRCUIT REFRIGERATOR/FREEZER
The paper reviews the refrigerant/freezer (RF) design and refrigerant selection process that is necessary to design an energy efficient RF that does not use fully halogenated chlorofluorocarbons (CFCs). EPA is interested in phasing out CFCs in RFs to minimize stratospheric ozone ...
Code of Federal Regulations, 2014 CFR
2014-10-01
...-contained breathing apparatus Self-contained breathing apparatus for refrigeration 1 Flame safety lamps... 100 2 1 1 1 Required only on vessels equipped with any refrigeration unit using ammonia to refrigerate any space with a volume of more than 20 cubic feet or with any refrigeration unit using fluorocarbons...
Code of Federal Regulations, 2012 CFR
2012-10-01
...-contained breathing apparatus Self-contained breathing apparatus for refrigeration 1 Flame safety lamps... 100 2 1 1 1 Required only on vessels equipped with any refrigeration unit using ammonia to refrigerate any space with a volume of more than 20 cubic feet or with any refrigeration unit using fluorocarbons...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-08-05
... Commercial and Industrial commercial and industrial Refrigeration Equipment Manufacturing. refrigeration... commercial refrigeration installation; HVAC contractors. This table is not intended to be exhaustive, but... servicing of existing refrigeration and air-conditioning equipment), with a total phaseout in 2030. The...
THERMODYNAMIC EVALUATION OF FIVE ALTERNATIVE REFRIGERANTS IN VAPOR-COMPRESSION CYCLES
The paper gives results of a thermodynamic evaluation of five alternative refrigerants in a vapor-compression refrigeration cycle, utilizing throttling, super-heating, and combined throttling and superheating. ive alternative refrigerants (R32, R125, R134a, R143a, and R152a) were...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-01-04
...; Transport Refrigeration Units; Request for Authorization; Opportunity for Public Hearing and Comment AGENCY... Diesel-Fueled Transport Refrigeration Units (TRU) and TRU Generator Sets and Facilities Where TRUs...''), regarding its ``Airborne Toxic Control Measure for In-Use Diesel-Fueled Transport Refrigeration Units (TRU...
Code of Federal Regulations, 2010 CFR
2010-10-01
...-contained breathing apparatus Self-contained breathing apparatus for refrigeration 1 Flame safety lamps... 100 2 1 1 1 Required only on vessels equipped with any refrigeration unit using ammonia to refrigerate any space with a volume of more than 20 cubic feet or with any refrigeration unit using fluorocarbons...
Code of Federal Regulations, 2013 CFR
2013-10-01
...-contained breathing apparatus Self-contained breathing apparatus for refrigeration 1 Flame safety lamps... 100 2 1 1 1 Required only on vessels equipped with any refrigeration unit using ammonia to refrigerate any space with a volume of more than 20 cubic feet or with any refrigeration unit using fluorocarbons...
Code of Federal Regulations, 2011 CFR
2011-10-01
...-contained breathing apparatus Self-contained breathing apparatus for refrigeration 1 Flame safety lamps... 100 2 1 1 1 Required only on vessels equipped with any refrigeration unit using ammonia to refrigerate any space with a volume of more than 20 cubic feet or with any refrigeration unit using fluorocarbons...
A historical look at chlorofluorocarbon refrigerants
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bhatti, M.S.
1999-07-01
A class of chemical compounds called chlorofluorocarbon refrigerants has been in widespread use since the 1930s in such diverse applications as refrigerants for refrigerating and air-conditioning systems, blowing agents for plastic foams, solvents for microelectronic circuitry and dry cleaning, sterilants for medical instruments, aerosol propellants for personal hygiene products and pesticides, and freezants for food. This paper describes the historical development of the chlorofluorocarbon refrigerants and gives brief biographical sketches of the inventors. 85 refs., 8 figs., 4 tabs.
NASA Astrophysics Data System (ADS)
Swift, G. W.
Malone refrigeration is the use of a liquid near its critical points without evaporations as working fluid in a regenerative or recuperative refrigeration cycle such as the Stirling and Brayton cycles. It's potential advantages include compactness, efficiency, an environmentally benign working fluid, and reasonable cost. One Malone refrigerator has been built and studied; two more are under construction. Malone refrigeration is such a new, relatively unexplored technology that the potential for inventions leading to improvements in efficiency and simplicity is very high.
Mixed Refrigerants for a Glass Capillary Micro Cryogenic Cooler
2010-08-01
refrigerant has the largest ðDhTÞmin 1.35 kJ/mol. To deliver 15 mW of gross refrigeration power, JT cryocoolers using mixed refrigerants only require 1.6...higher than 75 K. Pressure drop in heat exchangers can cause refrigeration loss in cryocooler systems. The minimum enthalpy difference and hence...micro- cryocoolers . They solved it by making the returning flow laminar through re-design- ing micro channels. Fig. 4 shows the relationship between the
Beshr, Mohamed; Aute, Vikrant; Abdelaziz, Omar; ...
2016-08-24
Refrigeration and air conditioning systems have high, negative environmental impacts due to refrigerant charge leaks from the system and their corresponding high global warming potential. Thus, many efforts are in progress to obtain suitable low GWP alternative refrigerants and more environmentally friendly systems for the future. In addition, the system’s life cycle climate performance (LCCP) is a widespread metric proposed for the evaluation of the system’s environmental impact.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Beshr, Mohamed; Aute, Vikrant; Abdelaziz, Omar
Refrigeration and air conditioning systems have high, negative environmental impacts due to refrigerant charge leaks from the system and their corresponding high global warming potential. Thus, many efforts are in progress to obtain suitable low GWP alternative refrigerants and more environmentally friendly systems for the future. In addition, the system’s life cycle climate performance (LCCP) is a widespread metric proposed for the evaluation of the system’s environmental impact.
NASA Astrophysics Data System (ADS)
Gill, Jatinder; Singh, Jagdev
2018-05-01
In this work, the experimental examination was carried out using a mixture of R134a and LPG refrigerant (consisting of R134a and LPG in a proportion of 28:72 by weight) as a replacement for R134a in a vapor compression refrigeration system. Exergy and energy tests were carried out at different evaporator and condenser temperatures with controlled environmental conditions. The results showed that the exergy destruction in the compressor, condenser, evaporator, and a capillary tube of the R134a / LPG refrigeration system was found lower by approximately 11.13-3.41%, 2.24-3.43%, 12.02-13.47% and 1.54-5.61% respectively. The compressor exhibits the highest level of destruction, accompanied by a condenser, an evaporator and a capillary tube in refrigeration systems. The refrigeration capacity, COP and power consumption of the compressor of the R134a /LPG refrigeration system were detected higher and lower compared to the R134a refrigeration system by about 7.04-11.41%, 15.1-17.82%, and 3.83-8.08% respectively. Also, the miscibility of R134a and LPG blend with mineral oil discovered good. The R134a and LPG refrigerant mixture proposed in this study perform superior to R134a from component-wise exergy and energy analyses under similar experimental conditions.
NASA Technical Reports Server (NTRS)
Garrett, Steven L.; Hofler, Thomas J.
1991-01-01
A new refrigerator which uses resonant high amplitude sound in inert gases to pump heat is described and demonstrated. The phasing of the thermoacoustic cycle is provided by thermal conduction. This 'natural' phasing allows the entire refrigerator to operate with only one moving part (the loudspeaker diaphragm). The thermoacoustic refrigerator has no sliding seals, requires no lubrication, uses only low-tolerance machine parts, and contains no expensive components. Because the compressor moving mass is typically small and the oscillation frequency is high, the small amount of vibration is very easily isolated. This low vibration and lack of sliding seals makes thermoacoustic refrigeration an excellent candidate for food refrigeration and commercial/residential air conditioning applications. The design, fabrication, and performance of the first practical, autonomous thermoacoustic refrigerator, which will be flown on the Space Shuttle (STS-42), are described, and designs for terrestrial applications are presented.
Compilation of current high energy physics experiments - Sept. 1978
DOE Office of Scientific and Technical Information (OSTI.GOV)
Addis, L.; Odian, A.; Row, G. M.
1978-09-01
This compilation of current high-energy physics experiments is a collaborative effort of the Berkeley Particle Data Group, the SLAC library, and the nine participating laboratories: Argonne (ANL), Brookhaven (BNL), CERN, DESY, Fermilab (FNAL), KEK, Rutherford (RHEL), Serpukhov (SERP), and SLAC. Nominally, the compilation includes summaries of all high-energy physics experiments at the above laboratories that were approved (and not subsequently withdrawn) before about June 1978, and had not completed taking of data by 1 January 1975. The experimental summaries are supplemented with three indexes to the compilation, several vocabulary lists giving names or abbreviations used, and a short summary ofmore » the beams at each of the laboratories (except Rutherford). The summaries themselves are included on microfiche. (RWR)« less
Are central venous catheter tip cultures reliable after 6-day refrigeration?
Bouza, Emilio; Guembe, Maria; Gómez, Haydee; Martín-Rabadán, Pablo; Rivera, Marisa; Alcalá, Luis
2009-07-01
Present guidelines recommend culturing only central venous catheter (CVC) tips from patients with suspected catheter-related bloodstream infection (CR-BSI). However, a high proportion of these suspicions are not confirmed. Moreover, CVC tip culture increases laboratory workload, and reports of colonization may be meaningless or misleading for the clinician. Our working hypothesis was that CVC tips should be refrigerated and cultured only in patients with positive blood cultures. We evaluated the effect of 6-day refrigeration of 215 CVC tips. We selected all the catheters with a significant count according to the Maki's roll-plate technique and randomly assigned them to 2 groups. In group A, the catheters were recultured after 24 h of refrigeration, and in group B, the catheters were recultured after 6 days more of refrigeration, so that the refrigeration time evaluated would be of 6 days. The yield of refrigerated CVC tips that grow significant colony counts of primary culture in group B was compared with the yield of refrigerated catheter tips in group A. The difference showed that 6-day refrigeration reduced the number of significant CVCs by 15.2%. Only 61 CVCs were obtained from patients with CR-BSI, and in most of them, blood cultures were already positive before CVC culture, so only 0.91% of the CR-BSI episodes would have been misdiagnosed as culture negative after refrigeration. Refrigeration of CVC tips sent for culture and culturing only those from patients with positive blood cultures reduce the workload in the microbiology laboratory without misdiagnosing CR-BSI.
Ternary Dy-Er-Al magnetic refrigerants
Gschneidner, Jr., Karl A.; Takeya, Hiroyuki
1995-07-25
A ternary magnetic refrigerant material comprising (Dy.sub.1-x Er.sub.x)Al.sub.2 for a magnetic refrigerator using the Joule-Brayton thermodynamic cycle spanning a temperature range from about 60K to about 10K, which can be adjusted by changing the Dy to Er ratio of the refrigerant.
The two-evaporator (located in the freezer and fresh food compartments) design of the Lorenz-Meutzner (L-M) refrigerator/freezer (R/F) makes it a leading candidate for use of zeotropic refrigerant mixtures. Zeotrophic mixtures can have significant temperature glides during evapor...
Solar Refrigerators Store Life-Saving Vaccines
NASA Technical Reports Server (NTRS)
2014-01-01
Former Johnson Space Center engineer David Bergeron used his experience on the Advanced Refrigeration Technology Team to found SunDanzer Refrigeration Inc., a company specializing in solar-powered refrigerators. The company has created a battery-free unit that provides safe storage for vaccines in rural and remote areas around the world.
Code of Federal Regulations, 2010 CFR
2010-07-01
... engines used for transportation refrigeration units? 1039.645 Section 1039.645 Protection of Environment... apply to engines used for transportation refrigeration units? Manufacturers may choose to use the provisions of this section for engines used in transportation refrigeration units (TRUs). The operating...
46 CFR 154.1750 - Butadiene or vinyl chloride: Refrigeration system.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 5 2014-10-01 2014-10-01 false Butadiene or vinyl chloride: Refrigeration system. 154... and Operating Requirements § 154.1750 Butadiene or vinyl chloride: Refrigeration system. A refrigeration system for butadiene or vinyl chloride must not use vapor compression unless it: (a) Avoids any...
46 CFR 154.1750 - Butadiene or vinyl chloride: Refrigeration system.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 5 2012-10-01 2012-10-01 false Butadiene or vinyl chloride: Refrigeration system. 154... and Operating Requirements § 154.1750 Butadiene or vinyl chloride: Refrigeration system. A refrigeration system for butadiene or vinyl chloride must not use vapor compression unless it: (a) Avoids any...
48 CFR 52.223-12 - Refrigeration Equipment and Air Conditioners.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 48 Federal Acquisition Regulations System 2 2013-10-01 2013-10-01 false Refrigeration Equipment... Provisions and Clauses 52.223-12 Refrigeration Equipment and Air Conditioners. As prescribed in 23.804(b), insert the following clause: Refrigeration Equipment and Air Conditioners (MAY 1995) The Contractor shall...
46 CFR 154.1735 - Methyl acetylene-propadiene mixture.
Code of Federal Regulations, 2011 CFR
2011-10-01
... mixture must have a refrigeration system without vapor compression or have a refrigeration system with the... separate cargo piping, vent piping, and refrigeration equipment for methyl acetylene-propadiene that are segregated from other cargo piping, vent piping and refrigeration equipment on the vessel. [CGD 74-289, 44 FR...
46 CFR 154.1735 - Methyl acetylene-propadiene mixture.
Code of Federal Regulations, 2014 CFR
2014-10-01
... mixture must have a refrigeration system without vapor compression or have a refrigeration system with the... separate cargo piping, vent piping, and refrigeration equipment for methyl acetylene-propadiene that are segregated from other cargo piping, vent piping and refrigeration equipment on the vessel. [CGD 74-289, 44 FR...
Code of Federal Regulations, 2014 CFR
2014-07-01
... engines used for transportation refrigeration units? 1039.645 Section 1039.645 Protection of Environment... apply to engines used for transportation refrigeration units? Manufacturers may choose to use the provisions of this section for engines used in transportation refrigeration units (TRUs). The operating...
46 CFR 154.1750 - Butadiene or vinyl chloride: Refrigeration system.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 5 2013-10-01 2013-10-01 false Butadiene or vinyl chloride: Refrigeration system. 154... and Operating Requirements § 154.1750 Butadiene or vinyl chloride: Refrigeration system. A refrigeration system for butadiene or vinyl chloride must not use vapor compression unless it: (a) Avoids any...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-06-14
... Petition for Waiver of Panasonic Appliances Refrigeration Systems Corporation of America Corporation... Panasonic Appliances Refrigeration Systems Corporation of America (PAPRSA) seeking an exemption from... Refrigeration Systems Corporation of America, meaning that it is the same manufacturer to which DOE granted the...
48 CFR 52.223-12 - Refrigeration Equipment and Air Conditioners.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 48 Federal Acquisition Regulations System 2 2011-10-01 2011-10-01 false Refrigeration Equipment... Provisions and Clauses 52.223-12 Refrigeration Equipment and Air Conditioners. As prescribed in 23.804(b), insert the following clause: Refrigeration Equipment and Air Conditioners (MAY 1995) The Contractor shall...
48 CFR 52.223-12 - Refrigeration Equipment and Air Conditioners.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 48 Federal Acquisition Regulations System 2 2014-10-01 2014-10-01 false Refrigeration Equipment... Provisions and Clauses 52.223-12 Refrigeration Equipment and Air Conditioners. As prescribed in 23.804(b), insert the following clause: Refrigeration Equipment and Air Conditioners (MAY 1995) The Contractor shall...
40 CFR 63.463 - Batch vapor and in-line cleaning machine standards.
Code of Federal Regulations, 2014 CFR
2014-07-01
... of 1.0, superheated vapor. 2 Freeboard refrigeration device, superheated vapor. 3 Working-mode cover, freeboard refrigeration device. 4 Reduced room draft, freeboard ratio of 1.0, superheated vapor. 5 Freeboard refrigeration device, reduced room draft. 6 Freeboard refrigeration device, freeboard ratio of 1.0. 7 Freeboard...
48 CFR 52.223-12 - Refrigeration Equipment and Air Conditioners.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 48 Federal Acquisition Regulations System 2 2010-10-01 2010-10-01 false Refrigeration Equipment... Provisions and Clauses 52.223-12 Refrigeration Equipment and Air Conditioners. As prescribed in 23.804(b), insert the following clause: Refrigeration Equipment and Air Conditioners (MAY 1995) The Contractor shall...
46 CFR 154.1735 - Methyl acetylene-propadiene mixture.
Code of Federal Regulations, 2013 CFR
2013-10-01
... mixture must have a refrigeration system without vapor compression or have a refrigeration system with the... separate cargo piping, vent piping, and refrigeration equipment for methyl acetylene-propadiene that are segregated from other cargo piping, vent piping and refrigeration equipment on the vessel. [CGD 74-289, 44 FR...
46 CFR 154.1750 - Butadiene or vinyl chloride: Refrigeration system.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 5 2010-10-01 2010-10-01 false Butadiene or vinyl chloride: Refrigeration system. 154... and Operating Requirements § 154.1750 Butadiene or vinyl chloride: Refrigeration system. A refrigeration system for butadiene or vinyl chloride must not use vapor compression unless it: (a) Avoids any...
Code of Federal Regulations, 2012 CFR
2012-07-01
... engines used for transportation refrigeration units? 1039.645 Section 1039.645 Protection of Environment... apply to engines used for transportation refrigeration units? Manufacturers may choose to use the provisions of this section for engines used in transportation refrigeration units (TRUs). The operating...
Code of Federal Regulations, 2013 CFR
2013-07-01
... engines used for transportation refrigeration units? 1039.645 Section 1039.645 Protection of Environment... apply to engines used for transportation refrigeration units? Manufacturers may choose to use the provisions of this section for engines used in transportation refrigeration units (TRUs). The operating...
46 CFR 154.1750 - Butadiene or vinyl chloride: Refrigeration system.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 5 2011-10-01 2011-10-01 false Butadiene or vinyl chloride: Refrigeration system. 154... and Operating Requirements § 154.1750 Butadiene or vinyl chloride: Refrigeration system. A refrigeration system for butadiene or vinyl chloride must not use vapor compression unless it: (a) Avoids any...
46 CFR 154.1735 - Methyl acetylene-propadiene mixture.
Code of Federal Regulations, 2012 CFR
2012-10-01
... mixture must have a refrigeration system without vapor compression or have a refrigeration system with the... separate cargo piping, vent piping, and refrigeration equipment for methyl acetylene-propadiene that are segregated from other cargo piping, vent piping and refrigeration equipment on the vessel. [CGD 74-289, 44 FR...
46 CFR 154.1735 - Methyl acetylene-propadiene mixture.
Code of Federal Regulations, 2010 CFR
2010-10-01
... mixture must have a refrigeration system without vapor compression or have a refrigeration system with the... separate cargo piping, vent piping, and refrigeration equipment for methyl acetylene-propadiene that are segregated from other cargo piping, vent piping and refrigeration equipment on the vessel. [CGD 74-289, 44 FR...
Status Of Sorption Cryogenic Refrigeration
NASA Technical Reports Server (NTRS)
Jones, Jack A.
1988-01-01
Report reviews sorption refrigeration. Developed for cooling infrared detectors, cryogenic research, and other advanced applications, sorption refrigerators have few moving parts, little vibration, and lifetimes of 10 years or more. Describes types of sorption stages, multistage and hybrid refrigeration systems, power requirements, cooling capacities, and advantages and disadvantages of various stages and systems.
Low-temperature magnetic refrigerator
Barclay, J.A.
1983-05-26
The invention relates to magnetic refrigeration and more particularly to low temperature refrigeration between about 4 and about 20 K, with an apparatus and method utilizing a belt of magnetic material passed in and out of a magnetic field with heat exchangers within and outside the field operably disposed to accomplish refrigeration.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-01-31
... for interim waiver; and (4) DOE rulemakings and waivers regarding commercial refrigeration equipment... authority to establish and amend test procedures for commercial refrigeration equipment. On December 8, 2006, DOE published a final rule adopting test procedures for commercial refrigeration equipment, effective...
Code of Federal Regulations, 2011 CFR
2011-07-01
... engines used for transportation refrigeration units? 1039.645 Section 1039.645 Protection of Environment... apply to engines used for transportation refrigeration units? Manufacturers may choose to use the provisions of this section for engines used in transportation refrigeration units (TRUs). The operating...
48 CFR 52.223-12 - Refrigeration Equipment and Air Conditioners.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 48 Federal Acquisition Regulations System 2 2012-10-01 2012-10-01 false Refrigeration Equipment... Provisions and Clauses 52.223-12 Refrigeration Equipment and Air Conditioners. As prescribed in 23.804(b), insert the following clause: Refrigeration Equipment and Air Conditioners (MAY 1995) The Contractor shall...
NASA Astrophysics Data System (ADS)
Bonne, François; Alamir, Mazen; Bonnay, Patrick
2014-01-01
In this paper, a physical method to obtain control-oriented dynamical models of large scale cryogenic refrigerators is proposed, in order to synthesize model-based advanced control schemes. These schemes aim to replace classical user experience designed approaches usually based on many independent PI controllers. This is particularly useful in the case where cryoplants are submitted to large pulsed thermal loads, expected to take place in the cryogenic cooling systems of future fusion reactors such as the International Thermonuclear Experimental Reactor (ITER) or the Japan Torus-60 Super Advanced Fusion Experiment (JT-60SA). Advanced control schemes lead to a better perturbation immunity and rejection, to offer a safer utilization of cryoplants. The paper gives details on how basic components used in the field of large scale helium refrigeration (especially those present on the 400W @1.8K helium test facility at CEA-Grenoble) are modeled and assembled to obtain the complete dynamic description of controllable subsystems of the refrigerator (controllable subsystems are namely the Joule-Thompson Cycle, the Brayton Cycle, the Liquid Nitrogen Precooling Unit and the Warm Compression Station). The complete 400W @1.8K (in the 400W @4.4K configuration) helium test facility model is then validated against experimental data and the optimal control of both the Joule-Thompson valve and the turbine valve is proposed, to stabilize the plant under highly variable thermals loads. This work is partially supported through the European Fusion Development Agreement (EFDA) Goal Oriented Training Program, task agreement WP10-GOT-GIRO.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bonne, François; Bonnay, Patrick; Alamir, Mazen
2014-01-29
In this paper, a physical method to obtain control-oriented dynamical models of large scale cryogenic refrigerators is proposed, in order to synthesize model-based advanced control schemes. These schemes aim to replace classical user experience designed approaches usually based on many independent PI controllers. This is particularly useful in the case where cryoplants are submitted to large pulsed thermal loads, expected to take place in the cryogenic cooling systems of future fusion reactors such as the International Thermonuclear Experimental Reactor (ITER) or the Japan Torus-60 Super Advanced Fusion Experiment (JT-60SA). Advanced control schemes lead to a better perturbation immunity and rejection,more » to offer a safer utilization of cryoplants. The paper gives details on how basic components used in the field of large scale helium refrigeration (especially those present on the 400W @1.8K helium test facility at CEA-Grenoble) are modeled and assembled to obtain the complete dynamic description of controllable subsystems of the refrigerator (controllable subsystems are namely the Joule-Thompson Cycle, the Brayton Cycle, the Liquid Nitrogen Precooling Unit and the Warm Compression Station). The complete 400W @1.8K (in the 400W @4.4K configuration) helium test facility model is then validated against experimental data and the optimal control of both the Joule-Thompson valve and the turbine valve is proposed, to stabilize the plant under highly variable thermals loads. This work is partially supported through the European Fusion Development Agreement (EFDA) Goal Oriented Training Program, task agreement WP10-GOT-GIRO.« less
Super energy saver heat pump with dynamic hybrid phase change material
Ally, Moonis Raza [Oak Ridge, TN; Tomlinson, John Jager [Knoxville, TN; Rice, Clifford Keith [Clinton, TN
2010-07-20
A heat pump has a refrigerant loop, a compressor in fluid communication with the refrigerant loop, at least one indoor heat exchanger in fluid communication with the refrigerant loop, and at least one outdoor heat exchanger in fluid communication with the refrigerant loop. The at least one outdoor heat exchanger has a phase change material in thermal communication with the refrigerant loop and in fluid communication with an outdoor environment. Other systems, devices, and methods are described.
Counterflow absorber for an absorption refrigeration system
Reimann, Robert C.
1984-01-01
An air-cooled, vertical tube absorber for an absorption refrigeration system is disclosed. Strong absorbent solution is supplied to the top of the absorber and refrigerant vapor is supplied to the bottom of the absorber to create a direct counterflow of refrigerant vapor and absorbent solution in the absorber. The refrigeration system is designed so that the volume flow rate of refrigerant vapor in the tubes of the absorber is sufficient to create a substantially direct counterflow along the entire length of each tube in the absorber. This provides several advantages for the absorber such as higher efficiency and improved heat transfer characteristics, and allows improved purging of non-condensibles from the absorber.
High-Performance, Low Environmental Impact Refrigerants
NASA Technical Reports Server (NTRS)
McCullough, E. T.; Dhooge, P. M.; Glass, S. M.; Nimitz, J. S.
2001-01-01
Refrigerants used in process and facilities systems in the US include R-12, R-22, R-123, R-134a, R-404A, R-410A, R-500, and R-502. All but R-134a, R-404A, and R-410A contain ozone-depleting substances that will be phased out under the Montreal Protocol. Some of the substitutes do not perform as well as the refrigerants they are replacing, require new equipment, and have relatively high global warming potentials (GWPs). New refrigerants are needed that addresses environmental, safety, and performance issues simultaneously. In efforts sponsored by Ikon Corporation, NASA Kennedy Space Center (KSC), and the US Environmental Protection Agency (EPA), ETEC has developed and tested a new class of refrigerants, the Ikon (registered) refrigerants, based on iodofluorocarbons (IFCs). These refrigerants are nonflammable, have essentially zero ozone-depletion potential (ODP), low GWP, high performance (energy efficiency and capacity), and can be dropped into much existing equipment.
Magnetic refrigeration for low-temperature applications
NASA Technical Reports Server (NTRS)
Barclay, J. A.
1985-01-01
The application of refrigeration at low temperatures ranging from production of liquid helium for medical imaging systems to cooling of infrared sensors on surveillance satellites is discussed. Cooling below about 15 K with regenerative refrigerators is difficult because of the decreasing thermal mass of the regenerator compared to that of the working material. In order to overcome this difficulty with helium gas as the working material, a heat exchanger plus a Joule-Thomson or other exponder is used. Regenerative magnetic refrigerators with magnetic solids as the working material have the same regenerator problem as gas refrigerators. This problem provides motivation for the development of nonregenerative magnetic refrigerators that span approximately 1 K to approximately 0 K. Particular emphasis is placed on high reliability and high efficiency. Calculations indicate considerable promise in this area. The principles, the potential, the problems, and the progress towards development of successful 4 to 20 K magnetic refrigerators are discussed.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Beshr, M.; Aute, V.; Sharma, V.
Supermarket refrigeration systems have high environmental impact due to their large refrigerant charge and high leak rates. Consequently, the interest in using low GWP refrigerants such as carbon dioxide (CO 2) and new refrigerant blends is increasing. In this study, an open-source Life Cycle Climate Performance (LCCP) framework is presented and used to compare the environmental impact of four supermarket refrigeration systems: a transcritical CO 2 booster system, a cascade CO 2/N-40 system, a combined secondary circuit with central DX N-40/L-40 system, and a baseline multiplex direct expansion system utilizing R-404A and N-40. The study is performed for different climatesmore » within the USA using EnergyPlus to simulate the systems' hourly performance. Finally, further analyses are presented such as parametric, sensitivity, and uncertainty analyses to study the impact of different system parameters on the LCCP.« less
Fault detection and diagnosis for refrigerator from compressor sensor
DOE Office of Scientific and Technical Information (OSTI.GOV)
Keres, Stephen L.; Gomes, Alberto Regio; Litch, Andrew D.
A refrigerator, a sealed refrigerant system, and method are provided where the refrigerator includes at least a refrigerated compartment and a sealed refrigerant system including an evaporator, a compressor, a condenser, a controller, an evaporator fan, and a condenser fan. The method includes monitoring a frequency of the compressor, and identifying a fault condition in the at least one component of the refrigerant sealed system in response to the compressor frequency. The method may further comprise calculating a compressor frequency rate based upon the rate of change of the compressor frequency, wherein a fault in the condenser fan is identifiedmore » if the compressor frequency rate is positive and exceeds a condenser fan fault threshold rate, and wherein a fault in the evaporator fan is identified if the compressor frequency rate is negative and exceeds an evaporator fan fault threshold rate.« less
Investigation of two-phase heat transfer coefficients of argon-freon cryogenic mixed refrigerants
NASA Astrophysics Data System (ADS)
Baek, Seungwhan; Lee, Cheonkyu; Jeong, Sangkwon
2014-11-01
Mixed refrigerant Joule Thomson refrigerators are widely used in various kinds of cryogenic systems these days. Although heat transfer coefficient estimation for a multi-phase and multi-component fluid in the cryogenic temperature range is necessarily required in the heat exchanger design of mixed refrigerant Joule Thomson refrigerators, it has been rarely discussed so far. In this paper, condensation and evaporation heat transfer coefficients of argon-freon mixed refrigerant are measured in a microchannel heat exchanger. A Printed Circuit Heat Exchanger (PCHE) with 340 μm hydraulic diameter has been developed as a compact microchannel heat exchanger and utilized in the experiment. Several two-phase heat transfer coefficient correlations are examined to discuss the experimental measurement results. The result of this paper shows that cryogenic two-phase mixed refrigerant heat transfer coefficients can be estimated by conventional two-phase heat transfer coefficient correlations.
Beshr, M.; Aute, V.; Sharma, V.; ...
2015-04-09
Supermarket refrigeration systems have high environmental impact due to their large refrigerant charge and high leak rates. Consequently, the interest in using low GWP refrigerants such as carbon dioxide (CO 2) and new refrigerant blends is increasing. In this study, an open-source Life Cycle Climate Performance (LCCP) framework is presented and used to compare the environmental impact of four supermarket refrigeration systems: a transcritical CO 2 booster system, a cascade CO 2/N-40 system, a combined secondary circuit with central DX N-40/L-40 system, and a baseline multiplex direct expansion system utilizing R-404A and N-40. The study is performed for different climatesmore » within the USA using EnergyPlus to simulate the systems' hourly performance. Finally, further analyses are presented such as parametric, sensitivity, and uncertainty analyses to study the impact of different system parameters on the LCCP.« less
Ternary Dy-Er-Al magnetic refrigerants
Gschneidner, K.A. Jr.; Takeya, Hiroyuki
1995-07-25
A ternary magnetic refrigerant material comprising (Dy{sub 1{minus}x}Er{sub x})Al{sub 2} for a magnetic refrigerator using the Joule-Brayton thermodynamic cycle spanning a temperature range from about 60K to about 10K, which can be adjusted by changing the Dy to Er ratio of the refrigerant. 29 figs.
49 CFR 173.5b - Portable and mobile refrigeration systems.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 49 Transportation 2 2013-10-01 2013-10-01 false Portable and mobile refrigeration systems. 173.5b...-GENERAL REQUIREMENTS FOR SHIPMENTS AND PACKAGINGS General § 173.5b Portable and mobile refrigeration... refrigeration systems, which may or may not be permanently mounted to a transport vehicle, used for agricultural...
ERIC Educational Resources Information Center
Ohio State Univ., Columbus. National Center for Research in Vocational Education.
This military-developed text consists of three blocks of instructional materials for use by those studying to become refrigeration and air conditioning specialists. Covered in the individual course blocks are the following topics: refrigeration and trouble analysis, thermodynamics, and principles of refrigeration; major components and domestic and…
10 CFR 431.302 - Definitions concerning walk-in coolers and walk-in freezers.
Code of Federal Regulations, 2013 CFR
2013-01-01
... walk-in cooler or walk-in freezer that are not part of its refrigeration system. K-factor means the... consumption, including, but not limited to, refrigeration, doors, lights, windows, or walls; or (2... temperature at or below 55 degrees Fahrenheit using a refrigeration system. Refrigeration system means the...
21 CFR 115.50 - Refrigeration of shell eggs held for retail distribution.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 2 2012-04-01 2012-04-01 false Refrigeration of shell eggs held for retail... SERVICES (CONTINUED) FOOD FOR HUMAN CONSUMPTION SHELL EGGS § 115.50 Refrigeration of shell eggs held for... interstate commerce, held for retail distribution: (1) Shall promptly be placed under refrigeration as...
10 CFR 431.302 - Definitions concerning walk-in coolers and walk-in freezers.
Code of Federal Regulations, 2014 CFR
2014-01-01
... walk-in cooler or walk-in freezer that are not part of its refrigeration system. K-factor means the... consumption, including, but not limited to, refrigeration, doors, lights, windows, or walls; or (2... temperature at or below 55 degrees Fahrenheit using a refrigeration system. Refrigeration system means the...
49 CFR 173.5b - Portable and mobile refrigeration systems.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 49 Transportation 2 2012-10-01 2012-10-01 false Portable and mobile refrigeration systems. 173.5b...-GENERAL REQUIREMENTS FOR SHIPMENTS AND PACKAGINGS General § 173.5b Portable and mobile refrigeration... refrigeration systems, which may or may not be permanently mounted to a transport vehicle, used for agricultural...
21 CFR 115.50 - Refrigeration of shell eggs held for retail distribution.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 2 2013-04-01 2013-04-01 false Refrigeration of shell eggs held for retail... SERVICES (CONTINUED) FOOD FOR HUMAN CONSUMPTION SHELL EGGS § 115.50 Refrigeration of shell eggs held for... interstate commerce, held for retail distribution: (1) Shall promptly be placed under refrigeration as...
21 CFR 115.50 - Refrigeration of shell eggs held for retail distribution.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 2 2014-04-01 2014-04-01 false Refrigeration of shell eggs held for retail... SERVICES (CONTINUED) FOOD FOR HUMAN CONSUMPTION SHELL EGGS § 115.50 Refrigeration of shell eggs held for... interstate commerce, held for retail distribution: (1) Shall promptly be placed under refrigeration as...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-03-05
... Refrigeration Institute 1230 (AHRI) as the alternative test procedure. DATES: This Decision and Order is... testing procedures or rating procedures developed or recognized by the Air-Conditioning and Refrigeration... Refrigeration Institute (AHRI) Standard 1230-2010: Performance Rating of Variable Refrigerant Flow (VRF) Multi...
10 CFR 431.302 - Definitions concerning walk-in coolers and walk-in freezers.
Code of Federal Regulations, 2012 CFR
2012-01-01
... walk-in cooler or walk-in freezer that are not part of its refrigeration system. K-factor means the... consumption, including, but not limited to, refrigeration, doors, lights, windows, or walls; or (2... temperature at or below 55 degrees Fahrenheit using a refrigeration system. Refrigeration system means the...
49 CFR 173.5b - Portable and mobile refrigeration systems.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 49 Transportation 2 2010-10-01 2010-10-01 false Portable and mobile refrigeration systems. 173.5b...-GENERAL REQUIREMENTS FOR SHIPMENTS AND PACKAGINGS General § 173.5b Portable and mobile refrigeration... refrigeration systems, which may or may not be permanently mounted to a transport vehicle, used for agricultural...
75 FR 32210 - Notice of Lodging of Consent Decree Under the Clean Air Act
Federal Register 2010, 2011, 2012, 2013, 2014
2010-06-07
... or verify recovery of refrigerant from appliances it accepts for disposal. The Consent Decree...) purchase equipment to recover refrigerant or contract for such services and provide such service at no... provided in appendix A; and (4) keep a refrigerant recovery log regarding refrigerant that it has recovered...
75 FR 38550 - Notice of Lodging of Consent Decree Under the Clean Air Act
Federal Register 2010, 2011, 2012, 2013, 2014
2010-07-02
... 82, Subpart F, by failing to follow the requirement to recover or verify recovery of refrigerant from... ability to pay. The Decree also requires Defendant to (1) purchase equipment to recover refrigerant or... a refrigerant recovery log regarding refrigerant that it has recovered. The Department of Justice...
21 CFR 864.9700 - Blood storage refrigerator and blood storage freezer.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Blood storage refrigerator and blood storage... Establishments That Manufacture Blood and Blood Products § 864.9700 Blood storage refrigerator and blood storage freezer. (a) Identification. A blood storage refrigerator and a blood storage freezer are devices intended...
21 CFR 864.9700 - Blood storage refrigerator and blood storage freezer.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Blood storage refrigerator and blood storage... Establishments That Manufacture Blood and Blood Products § 864.9700 Blood storage refrigerator and blood storage freezer. (a) Identification. A blood storage refrigerator and a blood storage freezer are devices intended...
21 CFR 864.9700 - Blood storage refrigerator and blood storage freezer.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Blood storage refrigerator and blood storage... Establishments That Manufacture Blood and Blood Products § 864.9700 Blood storage refrigerator and blood storage freezer. (a) Identification. A blood storage refrigerator and a blood storage freezer are devices intended...
21 CFR 864.9700 - Blood storage refrigerator and blood storage freezer.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Blood storage refrigerator and blood storage... Establishments That Manufacture Blood and Blood Products § 864.9700 Blood storage refrigerator and blood storage freezer. (a) Identification. A blood storage refrigerator and a blood storage freezer are devices intended...
21 CFR 864.9700 - Blood storage refrigerator and blood storage freezer.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Blood storage refrigerator and blood storage... Establishments That Manufacture Blood and Blood Products § 864.9700 Blood storage refrigerator and blood storage freezer. (a) Identification. A blood storage refrigerator and a blood storage freezer are devices intended...
Code of Federal Regulations, 2010 CFR
2010-01-01
... consumption of refrigerated bottled or canned beverage vending machines. 431.294 Section 431.294 Energy... method for the measurement of energy consumption of refrigerated bottled or canned beverage vending... test procedure for energy consumption of refrigerated bottled or canned beverage vending machines shall...
Applicability of ASST-A helium refrigeration system for JLab End Station Refrigerator
NASA Astrophysics Data System (ADS)
Hasan, N.; Knudsen, P.; Ganni, V.
2017-12-01
The MØLLER experiment at Jefferson Lab (JLab) is a high power (5 kW) liquid hydrogen target scheduled to be operational in the 12 GeV-era. At present, cryogenic loads and targets at three of JLab’s four experimental halls are supported by the End Station Refrigerator (ESR) - a CTI/Helix 1.5 kW 4.5 K refrigerator. It is not capable of supporting the high power target load and a capacity upgrade of the ESR cryogenic system is essential. The ASST-A helium refrigeration system is a 4 kW 4.5 K refrigerator. It was designed and used for the Superconducting Super Collider Lab (SSCL) magnet string test and later obtained by JLab after the cancellation of that project. The modified ASST-A refrigeration system, which will be called ESR-II along with a support flow from JLab’s Central Helium Liquefier (CHL) is considered as an option for the End Station Refrigerator capacity upgrade. The applicability of this system for ESR-II under varying load conditions is investigated. The present paper outlines the findings of this process study.
Demonstration of the Use of Remote Temperature Monitoring Devices in Vaccine Refrigerators in Haiti.
Cavallaro, Kathleen F; Francois, Jeannot; Jacques, Roody; Mentor, Derline; Yalcouye, Idrissa; Wilkins, Karen; Mueller, Nathan; Turner, Rebecca; Wallace, Aaron; Tohme, Rania A
After the 2010 earthquake, Haiti committed to introducing 4 new antigens into its routine immunization schedule, which required improving its cold chain (ie, temperature-controlled supply chain) and increasing vaccine storage capacity by installing new refrigerators. We tested the feasibility of using remote temperature monitoring devices (RTMDs) in Haiti in a sample of vaccine refrigerators fueled by solar panels, propane gas, or electricity. We analyzed data from 16 RTMDs monitoring 24 refrigerators in 15 sites from March through August 2014. Although 5 of the 16 RTMDs exhibited intermittent data gaps, we identified typical temperature patterns consistent with refrigerator door opening and closing, propane depletion, thermostat insufficiency, and overstocking. Actual start-up, annual maintenance, and annual electricity costs for using RTMDs were $686, $179, and $9 per refrigerator, respectively. In Haiti, RTMD use was feasible. RTMDs could be prioritized for use with existing refrigerators with high volumes of vaccines and new refrigerators to certify their functionality before use. Vaccine vial monitors could provide additional useful information about cumulative heat exposure and possible vaccine denaturation.
Energy Efficiency and Environmental Impact Analyses of Supermarket Refrigeration Systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fricke, Brian A; Bansal, Pradeep; Zha, Shitong
This paper presents energy and life cycle climate performance (LCCP) analyses of a variety of supermarket refrigeration systems to identify designs that exhibit low environmental impact and high energy efficiency. EnergyPlus was used to model refrigeration systems in a variety of climate zones across the United States. The refrigeration systems that were modeled include the traditional multiplex DX system, cascade systems with secondary loops and the transcritical CO2 system. Furthermore, a variety of refrigerants were investigated, including R-32, R-134a, R-404A, R-1234yf, R-717, and R-744. LCCP analysis was used to determine the direct and indirect carbon dioxide emissions resulting from themore » operation of the various refrigeration systems over their lifetimes. Our analysis revealed that high-efficiency supermarket refrigeration systems may result in up to 44% less energy consumption and 78% reduced carbon dioxide emissions compared to the baseline multiplex DX system. This is an encouraging result for legislators, policy makers and supermarket owners to select low emission, high-efficiency commercial refrigeration system designs for future retrofit and new projects.« less
NASA Astrophysics Data System (ADS)
Gu, Rui
Vapor compression cycles are widely used in heating, refrigerating and air-conditioning. A slight performance improvement in the components of a vapor compression cycle, such as the compressor, can play a significant role in saving energy use. However, the complexity and cost of these improvements can block their application in the market. Modifying the conventional cycle configuration can offer a less complex and less costly alternative approach. Economizing is a common modification for improving the performance of the refrigeration cycle, resulting in decreasing the work required to compress the gas per unit mass. Traditionally, economizing requires multi-stage compressors, the cost of which has restrained the scope for practical implementation. Compressors with injection ports, which can be used to inject economized refrigerant during the compression process, introduce new possibilities for economization with less cost. This work focuses on computationally investigating a refrigeration system performance with two-phase fluid injection, developing a better understanding of the impact of injected refrigerant quality on refrigeration system performance as well as evaluating the potential COP improvement that injection provides based on refrigeration system performance provided by Copeland.