Sample records for registration evaluation authorization

  1. Experimental study of digital image processing techniques for LANDSAT data

    NASA Technical Reports Server (NTRS)

    Rifman, S. S. (Principal Investigator); Allendoerfer, W. B.; Caron, R. H.; Pemberton, L. J.; Mckinnon, D. M.; Polanski, G.; Simon, K. W.

    1976-01-01

    The author has identified the following significant results. Results are reported for: (1) subscene registration, (2) full scene rectification and registration, (3) resampling techniques, (4) and ground control point (GCP) extraction. Subscenes (354 pixels x 234 lines) were registered to approximately 1/4 pixel accuracy and evaluated by change detection imagery for three cases: (1) bulk data registration, (2) precision correction of a reference subscene using GCP data, and (3) independently precision processed subscenes. Full scene rectification and registration results were evaluated by using a correlation technique to measure registration errors of 0.3 pixel rms thoughout the full scene. Resampling evaluations of nearest neighbor and TRW cubic convolution processed data included change detection imagery and feature classification. Resampled data were also evaluated for an MSS scene containing specular solar reflections.

  2. A Bayesian nonrigid registration method to enhance intraoperative target definition in image-guided prostate procedures through uncertainty characterization

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pursley, Jennifer; Risholm, Petter; Fedorov, Andriy

    2012-11-15

    Purpose: This study introduces a probabilistic nonrigid registration method for use in image-guided prostate brachytherapy. Intraoperative imaging for prostate procedures, usually transrectal ultrasound (TRUS), is typically inferior to diagnostic-quality imaging of the pelvis such as endorectal magnetic resonance imaging (MRI). MR images contain superior detail of the prostate boundaries and provide substructure features not otherwise visible. Previous efforts to register diagnostic prostate images with the intraoperative coordinate system have been deterministic and did not offer a measure of the registration uncertainty. The authors developed a Bayesian registration method to estimate the posterior distribution on deformations and provide a case-specific measuremore » of the associated registration uncertainty. Methods: The authors adapted a biomechanical-based probabilistic nonrigid method to register diagnostic to intraoperative images by aligning a physician's segmentations of the prostate in the two images. The posterior distribution was characterized with a Markov Chain Monte Carlo method; the maximum a posteriori deformation and the associated uncertainty were estimated from the collection of deformation samples drawn from the posterior distribution. The authors validated the registration method using a dataset created from ten patients with MRI-guided prostate biopsies who had both diagnostic and intraprocedural 3 Tesla MRI scans. The accuracy and precision of the estimated posterior distribution on deformations were evaluated from two predictive distance distributions: between the deformed central zone-peripheral zone (CZ-PZ) interface and the physician-labeled interface, and based on physician-defined landmarks. Geometric margins on the registration of the prostate's peripheral zone were determined from the posterior predictive distance to the CZ-PZ interface separately for the base, mid-gland, and apical regions of the prostate. Results: The authors observed variation in the shape and volume of the segmented prostate in diagnostic and intraprocedural images. The probabilistic method allowed us to convey registration results in terms of posterior distributions, with the dispersion providing a patient-specific estimate of the registration uncertainty. The median of the predictive distance distribution between the deformed prostate boundary and the segmented boundary was Less-Than-Or-Slanted-Equal-To 3 mm (95th percentiles within {+-}4 mm) for all ten patients. The accuracy and precision of the internal deformation was evaluated by comparing the posterior predictive distance distribution for the CZ-PZ interface for each patient, with the median distance ranging from -0.6 to 2.4 mm. Posterior predictive distances between naturally occurring landmarks showed registration errors of Less-Than-Or-Slanted-Equal-To 5 mm in any direction. The uncertainty was not a global measure, but instead was local and varied throughout the registration region. Registration uncertainties were largest in the apical region of the prostate. Conclusions: Using a Bayesian nonrigid registration method, the authors determined the posterior distribution on deformations between diagnostic and intraprocedural MR images and quantified the uncertainty in the registration results. The feasibility of this approach was tested and results were positive. The probabilistic framework allows us to evaluate both patient-specific and location-specific estimates of the uncertainty in the registration result. Although the framework was tested on MR-guided procedures, the preliminary results suggest that it may be applied to TRUS-guided procedures as well, where the addition of diagnostic MR information may have a larger impact on target definition and clinical guidance.« less

  3. A Bayesian nonrigid registration method to enhance intraoperative target definition in image-guided prostate procedures through uncertainty characterization

    PubMed Central

    Pursley, Jennifer; Risholm, Petter; Fedorov, Andriy; Tuncali, Kemal; Fennessy, Fiona M.; Wells, William M.; Tempany, Clare M.; Cormack, Robert A.

    2012-01-01

    Purpose: This study introduces a probabilistic nonrigid registration method for use in image-guided prostate brachytherapy. Intraoperative imaging for prostate procedures, usually transrectal ultrasound (TRUS), is typically inferior to diagnostic-quality imaging of the pelvis such as endorectal magnetic resonance imaging (MRI). MR images contain superior detail of the prostate boundaries and provide substructure features not otherwise visible. Previous efforts to register diagnostic prostate images with the intraoperative coordinate system have been deterministic and did not offer a measure of the registration uncertainty. The authors developed a Bayesian registration method to estimate the posterior distribution on deformations and provide a case-specific measure of the associated registration uncertainty. Methods: The authors adapted a biomechanical-based probabilistic nonrigid method to register diagnostic to intraoperative images by aligning a physician's segmentations of the prostate in the two images. The posterior distribution was characterized with a Markov Chain Monte Carlo method; the maximum a posteriori deformation and the associated uncertainty were estimated from the collection of deformation samples drawn from the posterior distribution. The authors validated the registration method using a dataset created from ten patients with MRI-guided prostate biopsies who had both diagnostic and intraprocedural 3 Tesla MRI scans. The accuracy and precision of the estimated posterior distribution on deformations were evaluated from two predictive distance distributions: between the deformed central zone-peripheral zone (CZ-PZ) interface and the physician-labeled interface, and based on physician-defined landmarks. Geometric margins on the registration of the prostate's peripheral zone were determined from the posterior predictive distance to the CZ-PZ interface separately for the base, mid-gland, and apical regions of the prostate. Results: The authors observed variation in the shape and volume of the segmented prostate in diagnostic and intraprocedural images. The probabilistic method allowed us to convey registration results in terms of posterior distributions, with the dispersion providing a patient-specific estimate of the registration uncertainty. The median of the predictive distance distribution between the deformed prostate boundary and the segmented boundary was ⩽3 mm (95th percentiles within ±4 mm) for all ten patients. The accuracy and precision of the internal deformation was evaluated by comparing the posterior predictive distance distribution for the CZ-PZ interface for each patient, with the median distance ranging from −0.6 to 2.4 mm. Posterior predictive distances between naturally occurring landmarks showed registration errors of ⩽5 mm in any direction. The uncertainty was not a global measure, but instead was local and varied throughout the registration region. Registration uncertainties were largest in the apical region of the prostate. Conclusions: Using a Bayesian nonrigid registration method, the authors determined the posterior distribution on deformations between diagnostic and intraprocedural MR images and quantified the uncertainty in the registration results. The feasibility of this approach was tested and results were positive. The probabilistic framework allows us to evaluate both patient-specific and location-specific estimates of the uncertainty in the registration result. Although the framework was tested on MR-guided procedures, the preliminary results suggest that it may be applied to TRUS-guided procedures as well, where the addition of diagnostic MR information may have a larger impact on target definition and clinical guidance. PMID:23127078

  4. Do emergency medicine journals promote trial registration and adherence to reporting guidelines? A survey of "Instructions for Authors".

    PubMed

    Sims, Matthew T; Henning, Nolan M; Wayant, C Cole; Vassar, Matt

    2016-11-24

    The aim of this study was to evaluate the current state of two publication practices, reporting guidelines requirements and clinical trial registration requirements, by analyzing the "Instructions for Authors" of emergency medicine journals. We performed a web-based data abstraction from the "Instructions for Authors" of the 27 Emergency Medicine journals catalogued in the Expanded Science Citation Index of the 2014 Journal Citation Reports and Google Scholar Metrics h5-index to identify whether each journal required, recommended, or made no mention of the following reporting guidelines: EQUATOR Network, ICMJE, ARRIVE, CARE, CONSORT, STARD, TRIPOD, CHEERS, MOOSE, STROBE, COREQ, SRQR, SQUIRE, PRISMA-P, SPIRIT, PRISMA, and QUOROM. We also extracted whether journals required or recommended trial registration. Authors were blinded to one another's ratings until completion of the data validation. Cross-tabulations and descriptive statistics were calculated using IBM SPSS 22. Of the 27 emergency medicine journals, 11 (11/27, 40.7%) did not mention a single guideline within their "Instructions for Authors," while the remaining 16 (16/27, 59.3%) mentioned one or more guidelines. The QUOROM statement and SRQR were not mentioned by any journals whereas the ICMJE guidelines (18/27, 66.7%) and CONSORT statement (15/27, 55.6%) were mentioned most often. Of the 27 emergency medicine journals, 15 (15/27, 55.6%) did not mention trial or review registration, while the remaining 12 (12/27, 44.4%) at least mentioned one of the two. Trial registration through ClinicalTrials.gov was mentioned by seven (7/27, 25.9%) journals while the WHO registry was mentioned by four (4/27, 14.8%). Twelve (12/27, 44.4%) journals mentioned trial registration through any registry platform. The aim of this study was to evaluate the current state of two publication practices, reporting guidelines requirements and clinical trial registration requirements, by analyzing the "Instructions for Authors" of emergency medicine journals. In this study, there was not a single reporting guideline mentioned in more than half of the journals. This undermines efforts of other journals to improve the completeness and transparency of research reporting. Reporting guidelines are infrequently required or recommended by emergency medicine journals. Furthermore, few require clinical trial registration. These two mechanisms may limit bias and should be considered for adoption by journal editors in emergency medicine. UMIN000022486.

  5. Evaluation of similarity measures for use in the intensity-based rigid 2D-3D registration for patient positioning in radiotherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wu Jian; Kim, Minho; Peters, Jorg

    2009-12-15

    Purpose: Rigid 2D-3D registration is an alternative to 3D-3D registration for cases where largely bony anatomy can be used for patient positioning in external beam radiation therapy. In this article, the authors evaluated seven similarity measures for use in the intensity-based rigid 2D-3D registration using a variation in Skerl's similarity measure evaluation protocol. Methods: The seven similarity measures are partitioned intensity uniformity, normalized mutual information (NMI), normalized cross correlation (NCC), entropy of the difference image, pattern intensity (PI), gradient correlation (GC), and gradient difference (GD). In contrast to traditional evaluation methods that rely on visual inspection or registration outcomes, themore » similarity measure evaluation protocol probes the transform parameter space and computes a number of similarity measure properties, which is objective and optimization method independent. The variation in protocol offers an improved property in the quantification of the capture range. The authors used this protocol to investigate the effects of the downsampling ratio, the region of interest, and the method of the digitally reconstructed radiograph (DRR) calculation [i.e., the incremental ray-tracing method implemented on a central processing unit (CPU) or the 3D texture rendering method implemented on a graphics processing unit (GPU)] on the performance of the similarity measures. The studies were carried out using both the kilovoltage (kV) and the megavoltage (MV) images of an anthropomorphic cranial phantom and the MV images of a head-and-neck cancer patient. Results: Both the phantom and the patient studies showed the 2D-3D registration using the GPU-based DRR calculation yielded better robustness, while providing similar accuracy compared to the CPU-based calculation. The phantom study using kV imaging suggested that NCC has the best accuracy and robustness, but its slow function value change near the global maximum requires a stricter termination condition for an optimization method. The phantom study using MV imaging indicated that PI, GD, and GC have the best accuracy, while NCC and NMI have the best robustness. The clinical study using MV imaging showed that NCC and NMI have the best robustness. Conclusions: The authors evaluated the performance of seven similarity measures for use in 2D-3D image registration using the variation in Skerl's similarity measure evaluation protocol. The generalized methodology can be used to select the best similarity measures, determine the optimal or near optimal choice of parameter, and choose the appropriate registration strategy for the end user in his specific registration applications in medical imaging.« less

  6. Main Reasons for Registration Application Refusal of Generic and Similar Pharmaceutical Drug Products by the Brazilian Health Regulatory Agency (ANVISA).

    PubMed

    do Carmo, Ana Cerúlia Moraes; Piras, Stefânia Schimaneski; Rocha, Nayrton Flávio Moura; Gratieri, Tais

    2017-01-01

    Objective . The marketing authorization of generic and similar pharmaceutical drug products involves the analysis of proposing company's administrative aspects as well as drug product technical description and scientific evaluations. This study evaluated the main reasons for registration refusal of generic and similar pharmaceutical drug products in Brazil. The aim is to help future applicants to better organize the proposal. Methods . A retrospective search of drug products registration processes was performed on the Brazilian Government Official Gazette from January 1, 2015, and December 31, 2015. Results . Drug product quality control, drug product stability study, deadline accomplishment, API quality control made by drug manufacturer, active pharmaceutical ingredient (API), and production report were the main reasons for marketing authorization application refusal of generic and similar pharmaceutical drug products in 2015. Conclusion . Disclosure of the reasons behind failed applications is a step forward on regulatory transparency. Sharing of experiences is essential to international regulatory authorities and organizations to improve legislation requirements for the marketing authorization of generic and similar pharmaceutical drug products.

  7. Main Reasons for Registration Application Refusal of Generic and Similar Pharmaceutical Drug Products by the Brazilian Health Regulatory Agency (ANVISA)

    PubMed Central

    do Carmo, Ana Cerúlia Moraes; Piras, Stefânia Schimaneski; Rocha, Nayrton Flávio Moura

    2017-01-01

    Objective. The marketing authorization of generic and similar pharmaceutical drug products involves the analysis of proposing company's administrative aspects as well as drug product technical description and scientific evaluations. This study evaluated the main reasons for registration refusal of generic and similar pharmaceutical drug products in Brazil. The aim is to help future applicants to better organize the proposal. Methods. A retrospective search of drug products registration processes was performed on the Brazilian Government Official Gazette from January 1, 2015, and December 31, 2015. Results. Drug product quality control, drug product stability study, deadline accomplishment, API quality control made by drug manufacturer, active pharmaceutical ingredient (API), and production report were the main reasons for marketing authorization application refusal of generic and similar pharmaceutical drug products in 2015. Conclusion. Disclosure of the reasons behind failed applications is a step forward on regulatory transparency. Sharing of experiences is essential to international regulatory authorities and organizations to improve legislation requirements for the marketing authorization of generic and similar pharmaceutical drug products. PMID:28280742

  8. Application of high-density data for hazard prediction, safety assesment, and risk characterization

    EPA Science Inventory

    There are long lists of chemicals that require some level of evaluation for safety determination. These include the European Union’s Registration, Evaluation, Authorization and Restriction of Chemical substances (REACH) program, Environment Canada’s existing substances evaluatio...

  9. Stopping Criteria for Log-Domain Diffeomorphic Demons Registration: An Experimental Survey for Radiotherapy Application.

    PubMed

    Peroni, M; Golland, P; Sharp, G C; Baroni, G

    2016-02-01

    A crucial issue in deformable image registration is achieving a robust registration algorithm at a reasonable computational cost. Given the iterative nature of the optimization procedure an algorithm must automatically detect convergence, and stop the iterative process when most appropriate. This paper ranks the performances of three stopping criteria and six stopping value computation strategies for a Log-Domain Demons Deformable registration method simulating both a coarse and a fine registration. The analyzed stopping criteria are: (a) velocity field update magnitude, (b) mean squared error, and (c) harmonic energy. Each stoping condition is formulated so that the user defines a threshold ∊, which quantifies the residual error that is acceptable for the particular problem and calculation strategy. In this work, we did not aim at assigning a value to e, but to give insights in how to evaluate and to set the threshold on a given exit strategy in a very popular registration scheme. Experiments on phantom and patient data demonstrate that comparing the optimization metric minimum over the most recent three iterations with the minimum over the fourth to sixth most recent iterations can be an appropriate algorithm stopping strategy. The harmonic energy was found to provide best trade-off between robustness and speed of convergence for the analyzed registration method at coarse registration, but was outperformed by mean squared error when all the original pixel information is used. This suggests the need of developing mathematically sound new convergence criteria in which both image and vector field information could be used to detect the actual convergence, which could be especially useful when considering multi-resolution registrations. Further work should be also dedicated to study same strategies performances in other deformable registration methods and body districts. © The Author(s) 2014.

  10. Registration factors that limit international mobility of people holding physiotherapy qualifications: A systematic review.

    PubMed

    Foo, Jonathan S; Storr, Michael; Maloney, Stephen

    2016-06-01

    There is no enforced international standardisation of the physiotherapy profession. Thus, registration is used in many countries to maintain standards of care and to protect the public. However, registration may also limit international workforce mobility. What is known about the professional registration factors that may limit the international mobility of people holding physiotherapy qualifications? Systematic review using an electronic database search and hand searching of the World Confederation for Physical Therapy and International Network of Physiotherapy Regulatory Authorities websites. Analysis was conducted using thematic analysis. 10 articles and eight websites were included from the search strategy. Data is representative of high-income English speaking countries. Four themes emerged regarding limitations to professional mobility: practice context, qualification recognition, verification of fitness to practice, and incidental limitations arising from the registration process. Professional mobility is limited by differences in physiotherapy education programmes, resulting in varying standards of competency. Thus, it is often necessary to verify clinical competencies through assessments, as well as determining professional attributes and ability to apply competencies in a different practice context, as part of the registration process. There has been little evaluation of registration practices, and at present, there is a need to re-evaluate current registration processes to ensure they are efficient and effective, thereby enhancing workforce mobility. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  11. 37 CFR 201.5 - Corrections and amplifications of copyright registrations; applications for supplementary...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ...) The year when the basic registration was completed; (iv) The name or names of the author or authors of... registration has been completed, any author or other copyright claimant of the work, or the owner of any exclusive right in the work, or the duly authorized agent of any such author, other claimant, or owner, who...

  12. 37 CFR 201.5 - Corrections and amplifications of copyright registrations; applications for supplementary...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...) The year when the basic registration was completed; (iv) The name or names of the author or authors of... registration has been completed, any author or other copyright claimant of the work, or the owner of any exclusive right in the work, or the duly authorized agent of any such author, other claimant, or owner, who...

  13. Prospective registration trends, reasons for retrospective registration and mechanisms to increase prospective registration compliance: descriptive analysis and survey.

    PubMed

    Hunter, Kylie Elizabeth; Seidler, Anna Lene; Askie, Lisa M

    2018-03-01

    To analyse prospective versus retrospective trial registration trends on the Australian New Zealand Clinical Trials Registry (ANZCTR) and to evaluate the reasons for non-compliance with prospective registration. Part 1: Descriptive analysis of trial registration trends from 2006 to 2015. Part 2: Online registrant survey. Part 1: All interventional trials registered on ANZCTR from 2006 to 2015. Part 2: Random sample of those who had retrospectively registered a trial on ANZCTR between 2010 and 2015. Part 1: Proportion of prospective versus retrospective clinical trial registrations (ie, registration before versus after enrolment of the first participant) on the ANZCTR overall and by various key metrics, such as sponsor, funder, recruitment country and sample size. Part 2: Reasons for non-compliance with prospective registration and perceived usefulness of various proposed mechanisms to improve prospective registration compliance. Part 1: Analysis of the complete dataset of 9450 trials revealed that compliance with prospective registration increased from 48% (216 out of 446 trials) in 2006 to 63% (723/1148) in 2012 and has since plateaued at around 64%. Patterns of compliance were relatively consistent across sponsor and funder types (industry vs non-industry), type of intervention (drug vs non-drug) and size of trial (n<100, 100-500, >500). However, primary sponsors from Australia/New Zealand were almost twice as likely to register prospectively (62%; 4613/7452) compared with sponsors from other countries with a WHO Network Registry (35%; 377/1084) or sponsors from countries without a WHO Registry (29%; 230/781). Part 2: The majority (56%; 84/149) of survey respondents cited lack of awareness as a reason for not registering their study prospectively. Seventy-four per cent (111/149) stated that linking registration to ethics approval would facilitate prospective registration. Despite some progress, compliance with prospective registration remains suboptimal. Linking registration to ethics approval was the favoured strategy among those sampled for improving compliance. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  14. REACH: impact on the US cosmetics industry?

    PubMed

    Pouillot, Anne; Polla, Barbara; Polla, Ada

    2009-03-01

    The Registration, Evaluation, Authorization and restriction of Chemicals (REACH) is a recent European regulation on chemical substances meant to protect human health and the environment. REACH imposes the "precautionary principle" where additional data and definitive action are required when uncertainty is identified. The cosmetics industry is only partially concerned by REACH: while the stages of registration and evaluation apply to cosmetics, those of authorization and restriction most likely will not, as cosmetic ingredients are already subject to regulation by various agencies and directives. REACH has potential benefits to the industry including the possibility of reassuring consumers and improving their image of chemicals and cosmetics. However, REACH also has potential disadvantages, mainly with regard to impeding innovation. The American cosmetics industry will be affected by REACH, because all US manufacturers who export substances to Europe will have to fully comply with REACH.

  15. Automatic patient alignment system using 3D ultrasound.

    PubMed

    Kaar, Marcus; Figl, Michael; Hoffmann, Rainer; Birkfellner, Wolfgang; Stock, Markus; Georg, Dietmar; Goldner, Gregor; Hummel, Johann

    2013-04-01

    Recent developments in radiation therapy such as intensity modulated radiotherapy (IMRT) or dose painting promise to provide better dose distribution on the tumor. For effective application of these methods the exact positioning of the patient and the localization of the irradiated organ and surrounding structures is crucial. Especially with respect to the treatment of the prostate, ultrasound (US) allows for differentiation between soft tissue and was therefore applied by various repositioning systems, such as BAT or Clarity. The authors built a new system which uses 3D US at both sites, the CT room and the intervention room and applied a 3D/3D US/US registration for automatic repositioning. In a first step the authors applied image preprocessing methods to prepare the US images for an optimal registration process. For the 3D/3D registration procedure five different metrics were evaluated. To find the image metric which fits best for a particular patient three 3D US images were taken at the CT site and registered to each other. From these results an US registration error was calculated. The most successful image metric was then applied for the US/US registration process. The success of the whole repositioning method was assessed by taking the results of an ExacTrac system as golden standard. The US/US registration error was found to be 2.99 ± 1.54 mm with respect to the mutual information metric by Mattes (eleven patients) which revealed to be the most suitable of the assessed metrics. For complete repositioning chain the error amounted to 4.15 ± 1.20 mm (ten patients). The authors developed a system for patient repositioning which works automatically without the necessity of user interaction with an accuracy which seems to be suitable for clinical application.

  16. Evaluation of Demons- and FEM-Based Registration Algorithms for Lung Cancer.

    PubMed

    Yang, Juan; Li, Dengwang; Yin, Yong; Zhao, Fen; Wang, Hongjun

    2016-04-01

    We evaluated and compared the accuracy of 2 deformable image registration algorithms in 4-dimensional computed tomography images for patients with lung cancer. Ten patients with non-small cell lung cancer or small cell lung cancer were enrolled in this institutional review board-approved study. The displacement vector fields relative to a specific reference image were calculated by using the diffeomorphic demons (DD) algorithm and the finite element method (FEM)-based algorithm. The registration accuracy was evaluated by using normalized mutual information (NMI), the sum of squared intensity difference (SSD), modified Hausdorff distance (dH_M), and ratio of gross tumor volume (rGTV) difference between reference image and deformed phase image. We also compared the registration speed of the 2 algorithms. Of all patients, the FEM-based algorithm showed stronger ability in aligning 2 images than the DD algorithm. The means (±standard deviation) of NMI were 0.86 (±0.05) and 0.90 (±0.05) using the DD algorithm and the FEM-based algorithm, respectively. The means of SSD were 0.006 (±0.003) and 0.003 (±0.002) using the DD algorithm and the FEM-based algorithm, respectively. The means of dH_M were 0.04 (±0.02) and 0.03 (±0.03) using the DD algorithm and the FEM-based algorithm, respectively. The means of rGTV were 3.9% (±1.01%) and 2.9% (±1.1%) using the DD algorithm and the FEM-based algorithm, respectively. However, the FEM-based algorithm costs a longer time than the DD algorithm, with the average running time of 31.4 minutes compared to 21.9 minutes for all patients. The preliminary results showed that the FEM-based algorithm was more accurate than the DD algorithm while compromised with the registration speed. © The Author(s) 2015.

  17. 21 CFR 1301.11 - Persons required to register; requirement of modification of registration authorizing activity as...

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... modification of registration authorizing activity as an online pharmacy. 1301.11 Section 1301.11 Food and Drugs... modification of registration authorizing activity as an online pharmacy. (a) Every person who manufactures... “online pharmacy” (as set forth in section 102(52) of the Act (21 U.S.C. 802(52)) and § 1300.04(h) of this...

  18. 21 CFR 1301.11 - Persons required to register; requirement of modification of registration authorizing activity as...

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... modification of registration authorizing activity as an online pharmacy. 1301.11 Section 1301.11 Food and Drugs... modification of registration authorizing activity as an online pharmacy. (a) Every person who manufactures... “online pharmacy” (as set forth in section 102(52) of the Act (21 U.S.C. 802(52)) and § 1300.04(h) of this...

  19. 21 CFR 1301.11 - Persons required to register; requirement of modification of registration authorizing activity as...

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... modification of registration authorizing activity as an online pharmacy. 1301.11 Section 1301.11 Food and Drugs... modification of registration authorizing activity as an online pharmacy. (a) Every person who manufactures... “online pharmacy” (as set forth in section 102(52) of the Act (21 U.S.C. 802(52)) and § 1300.04(h) of this...

  20. 21 CFR 1301.11 - Persons required to register; requirement of modification of registration authorizing activity as...

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... modification of registration authorizing activity as an online pharmacy. 1301.11 Section 1301.11 Food and Drugs... modification of registration authorizing activity as an online pharmacy. (a) Every person who manufactures... “online pharmacy” (as set forth in section 102(52) of the Act (21 U.S.C. 802(52)) and § 1300.04(h) of this...

  1. 21 CFR 1301.11 - Persons required to register; requirement of modification of registration authorizing activity as...

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... modification of registration authorizing activity as an online pharmacy. 1301.11 Section 1301.11 Food and Drugs... modification of registration authorizing activity as an online pharmacy. (a) Every person who manufactures... “online pharmacy” (as set forth in section 102(52) of the Act (21 U.S.C. 802(52)) and § 1300.04(h) of this...

  2. 47 CFR 17.5 - Commission consideration of applications for station authorization.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... station authorization. 17.5 Section 17.5 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL... of applications for station authorization. (a) Applications for station authorization, excluding... required, the registrant must supply the structure's registration number upon request by the Commission. (c...

  3. 47 CFR 17.5 - Commission consideration of applications for station authorization.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... station authorization. 17.5 Section 17.5 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL... of applications for station authorization. (a) Applications for station authorization, excluding... required, the registrant must supply the structure's registration number upon request by the Commission. (c...

  4. 47 CFR 17.5 - Commission consideration of applications for station authorization.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... station authorization. 17.5 Section 17.5 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL... of applications for station authorization. (a) Applications for station authorization, excluding... required, the registrant must supply the structure's registration number upon request by the Commission. (c...

  5. 47 CFR 17.5 - Commission consideration of applications for station authorization.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... station authorization. 17.5 Section 17.5 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL... of applications for station authorization. (a) Applications for station authorization, excluding... required, the registrant must supply the structure's registration number upon request by the Commission. (c...

  6. 47 CFR 17.5 - Commission consideration of applications for station authorization.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... station authorization. 17.5 Section 17.5 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL... of applications for station authorization. (a) Applications for station authorization, excluding... required, the registrant must supply the structure's registration number upon request by the Commission. (c...

  7. Comparison of image registration based measures of regional lung ventilation from dynamic spiral CT with Xe-CT

    PubMed Central

    Ding, Kai; Cao, Kunlin; Fuld, Matthew K.; Du, Kaifang; Christensen, Gary E.; Hoffman, Eric A.; Reinhardt, Joseph M.

    2012-01-01

    Purpose: Regional lung volume change as a function of lung inflation serves as an index of parenchymal and airway status as well as an index of regional ventilation and can be used to detect pathologic changes over time. In this paper, the authors propose a new regional measure of lung mechanics—the specific air volume change by corrected Jacobian. The authors compare this new measure, along with two existing registration based measures of lung ventilation, to a regional ventilation measurement derived from xenon-CT (Xe-CT) imaging. Methods: 4DCT and Xe-CT datasets from four adult sheep are used in this study. Nonlinear, 3D image registration is applied to register an image acquired near end inspiration to an image acquired near end expiration. Approximately 200 annotated anatomical points are used as landmarks to evaluate registration accuracy. Three different registration based measures of regional lung mechanics are derived and compared: the specific air volume change calculated from the Jacobian (SAJ); the specific air volume change calculated by the corrected Jacobian (SACJ); and the specific air volume change by intensity change (SAI). The authors show that the commonly used SAI measure can be derived from the direct SAJ measure by using the air-tissue mixture model and assuming there is no tissue volume change between the end inspiration and end expiration datasets. All three ventilation measures are evaluated by comparing to Xe-CT estimates of regional ventilation. Results: After registration, the mean registration error is on the order of 1 mm. For cubical regions of interest (ROIs) in cubes with size 20 mm × 20 mm × 20 mm, the SAJ and SACJ measures show significantly higher correlation (linear regression, average r2 = 0.75 and r2 = 0.82) with the Xe-CT based measure of specific ventilation (sV) than the SAI measure. For ROIs in slabs along the ventral-dorsal vertical direction with size of 150 mm × 8 mm × 40 mm, the SAJ, SACJ, and SAI all show high correlation (linear regression, average r2 = 0.88, r2 = 0.92, and r2 = 0.87) with the Xe-CT based sV without significant differences when comparing between the three methods. The authors demonstrate a linear relationship between the difference of specific air volume change and difference of tissue volume in all four animals (linear regression, average r2 = 0.86). Conclusions: Given a deformation field by an image registration algorithm, significant differences between the SAJ, SACJ, and SAI measures were found at a regional level compared to the Xe-CT sV in four sheep that were studied. The SACJ introduced here, provides better correlations with Xe-CT based sV than the SAJ and SAI measures, thus providing an improved surrogate for regional ventilation. PMID:22894434

  8. Validation of a deformable MRI to CT registration algorithm employing same day planning MRI for surrogate analysis.

    PubMed

    Padgett, Kyle R; Stoyanova, Radka; Pirozzi, Sara; Johnson, Perry; Piper, Jon; Dogan, Nesrin; Pollack, Alan

    2018-03-01

    Validating deformable multimodality image registrations is challenging due to intrinsic differences in signal characteristics and their spatial intensity distributions. Evaluating multimodality registrations using these spatial intensity distributions is also complicated by the fact that these metrics are often employed in the registration optimization process. This work evaluates rigid and deformable image registrations of the prostate in between diagnostic-MRI and radiation treatment planning-CT by utilizing a planning-MRI after fiducial marker placement as a surrogate. The surrogate allows for the direct quantitative analysis that can be difficult in the multimodality domain. For thirteen prostate patients, T2 images were acquired at two different time points, the first several weeks prior to planning (diagnostic-MRI) and the second on the same day as the planning-CT (planning-MRI). The diagnostic-MRI was deformed to the planning-CT utilizing a commercially available algorithm which synthesizes a deformable image registration (DIR) algorithm from local rigid registrations. The planning-MRI provided an independent surrogate for the planning-CT for assessing registration accuracy using image similarity metrics, including Pearson correlation and normalized mutual information (NMI). A local analysis was performed by looking only within the prostate, proximal seminal vesicles, penile bulb, and combined areas. The planning-MRI provided an excellent surrogate for the planning-CT with residual error in fiducial alignment between the two datasets being submillimeter, 0.78 mm. DIR was superior to the rigid registration in 11 of 13 cases demonstrating a 27.37% improvement in NMI (P < 0.009) within a regional area surrounding the prostate and associated critical organs. Pearson correlations showed similar results, demonstrating a 13.02% improvement (P < 0.013). By utilizing the planning-MRI as a surrogate for the planning-CT, an independent evaluation of registration accuracy is possible. This population provides an ideal testing ground for MRI to CT DIR by obviating the need for multimodality comparisons which are inherently more challenging. © 2018 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine.

  9. Estimating nonrigid motion from inconsistent intensity with robust shape features

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liu, Wenyang; Ruan, Dan, E-mail: druan@mednet.ucla.edu; Department of Radiation Oncology, University of California, Los Angeles, California 90095

    2013-12-15

    Purpose: To develop a nonrigid motion estimation method that is robust to heterogeneous intensity inconsistencies amongst the image pairs or image sequence. Methods: Intensity and contrast variations, as in dynamic contrast enhanced magnetic resonance imaging, present a considerable challenge to registration methods based on general discrepancy metrics. In this study, the authors propose and validate a novel method that is robust to such variations by utilizing shape features. The geometry of interest (GOI) is represented with a flexible zero level set, segmented via well-behaved regularized optimization. The optimization energy drives the zero level set to high image gradient regions, andmore » regularizes it with area and curvature priors. The resulting shape exhibits high consistency even in the presence of intensity or contrast variations. Subsequently, a multiscale nonrigid registration is performed to seek a regular deformation field that minimizes shape discrepancy in the vicinity of GOIs. Results: To establish the working principle, realistic 2D and 3D images were subject to simulated nonrigid motion and synthetic intensity variations, so as to enable quantitative evaluation of registration performance. The proposed method was benchmarked against three alternative registration approaches, specifically, optical flow, B-spline based mutual information, and multimodality demons. When intensity consistency was satisfied, all methods had comparable registration accuracy for the GOIs. When intensities among registration pairs were inconsistent, however, the proposed method yielded pronounced improvement in registration accuracy, with an approximate fivefold reduction in mean absolute error (MAE = 2.25 mm, SD = 0.98 mm), compared to optical flow (MAE = 9.23 mm, SD = 5.36 mm), B-spline based mutual information (MAE = 9.57 mm, SD = 8.74 mm) and mutimodality demons (MAE = 10.07 mm, SD = 4.03 mm). Applying the proposed method on a real MR image sequence also provided qualitatively appealing results, demonstrating good feasibility and applicability of the proposed method. Conclusions: The authors have developed a novel method to estimate the nonrigid motion of GOIs in the presence of spatial intensity and contrast variations, taking advantage of robust shape features. Quantitative analysis and qualitative evaluation demonstrated good promise of the proposed method. Further clinical assessment and validation is being performed.« less

  10. Estimating nonrigid motion from inconsistent intensity with robust shape features.

    PubMed

    Liu, Wenyang; Ruan, Dan

    2013-12-01

    To develop a nonrigid motion estimation method that is robust to heterogeneous intensity inconsistencies amongst the image pairs or image sequence. Intensity and contrast variations, as in dynamic contrast enhanced magnetic resonance imaging, present a considerable challenge to registration methods based on general discrepancy metrics. In this study, the authors propose and validate a novel method that is robust to such variations by utilizing shape features. The geometry of interest (GOI) is represented with a flexible zero level set, segmented via well-behaved regularized optimization. The optimization energy drives the zero level set to high image gradient regions, and regularizes it with area and curvature priors. The resulting shape exhibits high consistency even in the presence of intensity or contrast variations. Subsequently, a multiscale nonrigid registration is performed to seek a regular deformation field that minimizes shape discrepancy in the vicinity of GOIs. To establish the working principle, realistic 2D and 3D images were subject to simulated nonrigid motion and synthetic intensity variations, so as to enable quantitative evaluation of registration performance. The proposed method was benchmarked against three alternative registration approaches, specifically, optical flow, B-spline based mutual information, and multimodality demons. When intensity consistency was satisfied, all methods had comparable registration accuracy for the GOIs. When intensities among registration pairs were inconsistent, however, the proposed method yielded pronounced improvement in registration accuracy, with an approximate fivefold reduction in mean absolute error (MAE = 2.25 mm, SD = 0.98 mm), compared to optical flow (MAE = 9.23 mm, SD = 5.36 mm), B-spline based mutual information (MAE = 9.57 mm, SD = 8.74 mm) and mutimodality demons (MAE = 10.07 mm, SD = 4.03 mm). Applying the proposed method on a real MR image sequence also provided qualitatively appealing results, demonstrating good feasibility and applicability of the proposed method. The authors have developed a novel method to estimate the nonrigid motion of GOIs in the presence of spatial intensity and contrast variations, taking advantage of robust shape features. Quantitative analysis and qualitative evaluation demonstrated good promise of the proposed method. Further clinical assessment and validation is being performed.

  11. Marker-free motion correction in weight-bearing cone-beam CT of the knee joint.

    PubMed

    Berger, M; Müller, K; Aichert, A; Unberath, M; Thies, J; Choi, J-H; Fahrig, R; Maier, A

    2016-03-01

    To allow for a purely image-based motion estimation and compensation in weight-bearing cone-beam computed tomography of the knee joint. Weight-bearing imaging of the knee joint in a standing position poses additional requirements for the image reconstruction algorithm. In contrast to supine scans, patient motion needs to be estimated and compensated. The authors propose a method that is based on 2D/3D registration of left and right femur and tibia segmented from a prior, motion-free reconstruction acquired in supine position. Each segmented bone is first roughly aligned to the motion-corrupted reconstruction of a scan in standing or squatting position. Subsequently, a rigid 2D/3D registration is performed for each bone to each of K projection images, estimating 6 × 4 × K motion parameters. The motion of individual bones is combined into global motion fields using thin-plate-spline extrapolation. These can be incorporated into a motion-compensated reconstruction in the backprojection step. The authors performed visual and quantitative comparisons between a state-of-the-art marker-based (MB) method and two variants of the proposed method using gradient correlation (GC) and normalized gradient information (NGI) as similarity measure for the 2D/3D registration. The authors evaluated their method on four acquisitions under different squatting positions of the same patient. All methods showed substantial improvement in image quality compared to the uncorrected reconstructions. Compared to NGI and MB, the GC method showed increased streaking artifacts due to misregistrations in lateral projection images. NGI and MB showed comparable image quality at the bone regions. Because the markers are attached to the skin, the MB method performed better at the surface of the legs where the authors observed slight streaking of the NGI and GC methods. For a quantitative evaluation, the authors computed the universal quality index (UQI) for all bone regions with respect to the motion-free reconstruction. The authors quantitative evaluation over regions around the bones yielded a mean UQI of 18.4 for no correction, 53.3 and 56.1 for the proposed method using GC and NGI, respectively, and 53.7 for the MB reference approach. In contrast to the authors registration-based corrections, the MB reference method caused slight nonrigid deformations at bone outlines when compared to a motion-free reference scan. The authors showed that their method based on the NGI similarity measure yields reconstruction quality close to the MB reference method. In contrast to the MB method, the proposed method does not require any preparation prior to the examination which will improve the clinical workflow and patient comfort. Further, the authors found that the MB method causes small, nonrigid deformations at the bone outline which indicates that markers may not accurately reflect the internal motion close to the knee joint. Therefore, the authors believe that the proposed method is a promising alternative to MB motion management.

  12. Marker-free motion correction in weight-bearing cone-beam CT of the knee joint

    PubMed Central

    Berger, M.; Müller, K.; Aichert, A.; Unberath, M.; Thies, J.; Choi, J.-H.; Fahrig, R.; Maier, A.

    2016-01-01

    Purpose: To allow for a purely image-based motion estimation and compensation in weight-bearing cone-beam computed tomography of the knee joint. Methods: Weight-bearing imaging of the knee joint in a standing position poses additional requirements for the image reconstruction algorithm. In contrast to supine scans, patient motion needs to be estimated and compensated. The authors propose a method that is based on 2D/3D registration of left and right femur and tibia segmented from a prior, motion-free reconstruction acquired in supine position. Each segmented bone is first roughly aligned to the motion-corrupted reconstruction of a scan in standing or squatting position. Subsequently, a rigid 2D/3D registration is performed for each bone to each of K projection images, estimating 6 × 4 × K motion parameters. The motion of individual bones is combined into global motion fields using thin-plate-spline extrapolation. These can be incorporated into a motion-compensated reconstruction in the backprojection step. The authors performed visual and quantitative comparisons between a state-of-the-art marker-based (MB) method and two variants of the proposed method using gradient correlation (GC) and normalized gradient information (NGI) as similarity measure for the 2D/3D registration. Results: The authors evaluated their method on four acquisitions under different squatting positions of the same patient. All methods showed substantial improvement in image quality compared to the uncorrected reconstructions. Compared to NGI and MB, the GC method showed increased streaking artifacts due to misregistrations in lateral projection images. NGI and MB showed comparable image quality at the bone regions. Because the markers are attached to the skin, the MB method performed better at the surface of the legs where the authors observed slight streaking of the NGI and GC methods. For a quantitative evaluation, the authors computed the universal quality index (UQI) for all bone regions with respect to the motion-free reconstruction. The authors quantitative evaluation over regions around the bones yielded a mean UQI of 18.4 for no correction, 53.3 and 56.1 for the proposed method using GC and NGI, respectively, and 53.7 for the MB reference approach. In contrast to the authors registration-based corrections, the MB reference method caused slight nonrigid deformations at bone outlines when compared to a motion-free reference scan. Conclusions: The authors showed that their method based on the NGI similarity measure yields reconstruction quality close to the MB reference method. In contrast to the MB method, the proposed method does not require any preparation prior to the examination which will improve the clinical workflow and patient comfort. Further, the authors found that the MB method causes small, nonrigid deformations at the bone outline which indicates that markers may not accurately reflect the internal motion close to the knee joint. Therefore, the authors believe that the proposed method is a promising alternative to MB motion management. PMID:26936708

  13. Motion tracking in the liver: Validation of a method based on 4D ultrasound using a nonrigid registration technique

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vijayan, Sinara, E-mail: sinara.vijayan@ntnu.no; Klein, Stefan; Hofstad, Erlend Fagertun

    Purpose: Treatments like radiotherapy and focused ultrasound in the abdomen require accurate motion tracking, in order to optimize dosage delivery to the target and minimize damage to critical structures and healthy tissues around the target. 4D ultrasound is a promising modality for motion tracking during such treatments. In this study, the authors evaluate the accuracy of motion tracking in the liver based on deformable registration of 4D ultrasound images. Methods: The offline analysis was performed using a nonrigid registration algorithm that was specifically designed for motion estimation from dynamic imaging data. The method registers the entire 4D image data sequencemore » in a groupwise optimization fashion, thus avoiding a bias toward a specifically chosen reference time point. Three healthy volunteers were scanned over several breathing cycles (12 s) from three different positions and angles on the abdomen; a total of nine 4D scans for the three volunteers. Well-defined anatomic landmarks were manually annotated in all 96 time frames for assessment of the automatic algorithm. The error of the automatic motion estimation method was compared with interobserver variability. The authors also performed experiments to investigate the influence of parameters defining the deformation field flexibility and evaluated how well the method performed with a lower temporal resolution in order to establish the minimum frame rate required for accurate motion estimation. Results: The registration method estimated liver motion with an error of 1 mm (75% percentile over all datasets), which was lower than the interobserver variability of 1.4 mm. The results were only slightly dependent on the degrees of freedom of the deformation model. The registration error increased to 2.8 mm with an eight times lower temporal resolution. Conclusions: The authors conclude that the methodology was able to accurately track the motion of the liver in the 4D ultrasound data. The authors believe that the method has potential in interventions on moving abdominal organs such as MR or ultrasound guided focused ultrasound therapy and radiotherapy, pending the method is enabled to run in real-time. The data and the annotations used for this study are made publicly available for those who would like to test other methods on 4D liver ultrasound data.« less

  14. A new markerless patient-to-image registration method using a portable 3D scanner.

    PubMed

    Fan, Yifeng; Jiang, Dongsheng; Wang, Manning; Song, Zhijian

    2014-10-01

    Patient-to-image registration is critical to providing surgeons with reliable guidance information in the application of image-guided neurosurgery systems. The conventional point-matching registration method, which is based on skin markers, requires expensive and time-consuming logistic support. Surface-matching registration with facial surface scans is an alternative method, but the registration accuracy is unstable and the error in the more posterior parts of the head is usually large because the scan range is limited. This study proposes a new surface-matching method using a portable 3D scanner to acquire a point cloud of the entire head to perform the patient-to-image registration. A new method for transforming the scan points from the device space into the patient space without calibration and tracking was developed. Five positioning targets were attached on a reference star, and their coordinates in the patient space were measured prior. During registration, the authors moved the scanner around the head to scan its entire surface as well as the positioning targets, and the scanner generated a unique point cloud in the device space. The coordinates of the positioning targets in the device space were automatically detected by the scanner, and a spatial transformation from the device space to the patient space could be calculated by registering them to their coordinates in the patient space that had been measured prior. A three-step registration algorithm was then used to register the patient space to the image space. The authors evaluated their method on a rigid head phantom and an elastic head phantom to verify its practicality and to calculate the target registration error (TRE) in different regions of the head phantoms. The authors also conducted an experiment with a real patient's data to test the feasibility of their method in the clinical environment. In the phantom experiments, the mean fiducial registration error between the device space and the patient space, the mean surface registration error, and the mean TRE of 15 targets on the surface of each phantom were 0.34 ± 0.01 mm and 0.33 ± 0.02 mm, 1.17 ± 0.02 mm and 1.34 ± 0.10 mm, and 1.06 ± 0.11 mm and 1.48 ± 0.21 mm, respectively. When grouping the targets according to their positions on the head, high accuracy was achieved in all parts of the head, and the TREs were similar across different regions. The authors compared their method with the current surface registration methods that use only a part of the facial surface on the elastic phantom, and the mean TRE of 15 targets was 1.48 ± 0.21 mm and 1.98 ± 0.53 mm, respectively. In a clinical experiment, the mean TRE of seven targets on the patient's head surface was 1.92 ± 0.18 mm, which was sufficient to meet clinical requirements. The proposed surface-matching registration method provides sufficient registration accuracy even in the posterior area of the head. The 3D point cloud of the entire head, including the facial surface and the back of the head, can be easily acquired using a portable 3D scanner. The scanner does not need to be calibrated prior or tracked by the optical tracking system during scanning.

  15. 2D-3D rigid registration to compensate for prostate motion during 3D TRUS-guided biopsy.

    PubMed

    De Silva, Tharindu; Fenster, Aaron; Cool, Derek W; Gardi, Lori; Romagnoli, Cesare; Samarabandu, Jagath; Ward, Aaron D

    2013-02-01

    Three-dimensional (3D) transrectal ultrasound (TRUS)-guided systems have been developed to improve targeting accuracy during prostate biopsy. However, prostate motion during the procedure is a potential source of error that can cause target misalignments. The authors present an image-based registration technique to compensate for prostate motion by registering the live two-dimensional (2D) TRUS images acquired during the biopsy procedure to a preacquired 3D TRUS image. The registration must be performed both accurately and quickly in order to be useful during the clinical procedure. The authors implemented an intensity-based 2D-3D rigid registration algorithm optimizing the normalized cross-correlation (NCC) metric using Powell's method. The 2D TRUS images acquired during the procedure prior to biopsy gun firing were registered to the baseline 3D TRUS image acquired at the beginning of the procedure. The accuracy was measured by calculating the target registration error (TRE) using manually identified fiducials within the prostate; these fiducials were used for validation only and were not provided as inputs to the registration algorithm. They also evaluated the accuracy when the registrations were performed continuously throughout the biopsy by acquiring and registering live 2D TRUS images every second. This measured the improvement in accuracy resulting from performing the registration, continuously compensating for motion during the procedure. To further validate the method using a more challenging data set, registrations were performed using 3D TRUS images acquired by intentionally exerting different levels of ultrasound probe pressures in order to measure the performance of our algorithm when the prostate tissue was intentionally deformed. In this data set, biopsy scenarios were simulated by extracting 2D frames from the 3D TRUS images and registering them to the baseline 3D image. A graphics processing unit (GPU)-based implementation was used to improve the registration speed. They also studied the correlation between NCC and TREs. The root-mean-square (RMS) TRE of registrations performed prior to biopsy gun firing was found to be 1.87 ± 0.81 mm. This was an improvement over 4.75 ± 2.62 mm before registration. When the registrations were performed every second during the biopsy, the RMS TRE was reduced to 1.63 ± 0.51 mm. For 3D data sets acquired under different probe pressures, the RMS TRE was found to be 3.18 ± 1.6 mm. This was an improvement from 6.89 ± 4.1 mm before registration. With the GPU based implementation, the registrations were performed with a mean time of 1.1 s. The TRE showed a weak correlation with the similarity metric. However, the authors measured a generally convex shape of the metric around the ground truth, which may explain the rapid convergence of their algorithm to accurate results. Registration to compensate for prostate motion during 3D TRUS-guided biopsy can be performed with a measured accuracy of less than 2 mm and a speed of 1.1 s, which is an important step toward improving the targeting accuracy of a 3D TRUS-guided biopsy system.

  16. Registration status and outcome reporting of trials published in core headache medicine journals.

    PubMed

    Rayhill, Melissa L; Sharon, Roni; Burch, Rebecca; Loder, Elizabeth

    2015-11-17

    To evaluate randomized controlled trial (RCT) registration and outcome reporting compliance in core headache medicine journals. We identified RCTs published in core journals (Headache, Cephalalgia, and the Journal of Headache and Pain) from 2005 through 2014. We searched articles for trial registration numbers, which were verified in the corresponding trial registry. We categorized trial funding sources as industry, academic, government, or mixed. We contacted corresponding authors to assess reasons for nonregistration. We evaluated whether primary outcomes in trial registries matched those in corresponding publications. The journals published 225 RCTs over the study period. Fifty-eight of 225 (26%) reported a trial registration number in the article that could be linked to a corresponding registry entry. Trial registration rates increased over the 9 years of the study. Forty-six of 118 (39%) of industry-funded studies were registered compared with 27% of academic and 0% of government-funded studies. Only 5% of RCTs were prospectively registered, reported primary outcomes identical to those in the trial registry, and did not report unacknowledged post hoc outcomes. The most common reason for nonregistration was lack of awareness. Only about a quarter of the articles published in the core headache medicine journals are compliant with trial registration, but compliance has increased over time. Selective reporting of outcomes remains a problem, and very few trials met all 3 reporting standards assessed in this study. Efforts to improve the quality of trial reporting in the headache literature should continue. © 2015 American Academy of Neurology.

  17. Challenges for the registration of vaccines in emerging countries: Differences in dossier requirements, application and evaluation processes.

    PubMed

    Dellepiane, Nora; Pagliusi, Sonia

    2018-06-07

    The divergence of regulatory requirements and processes in developing and emerging countries contributes to hamper vaccines' registration, and therefore delay access to high-quality, safe and efficacious vaccines for their respective populations. This report focuses on providing insights on the heterogeneity of registration requirements in terms of numbering structure and overall content of dossiers for marketing authorisation applications for vaccines in different areas of the world. While it also illustrates the divergence of regulatory processes in general, as well as the need to avoid redundant reviews, it does not claim to provide a comprehensive view of all processes nor existing facilitating mechanisms, nor is it intended to touch upon the differences in assessments made by different regulatory authorities. This report describes the work analysed by regulatory experts from vaccine manufacturing companies during a meeting held in Geneva in May 2017, in identifying and quantifying differences in the requirements for vaccine registration in three aspects for comparison: the dossier numbering structure and contents, the application forms, and the evaluation procedures, in different countries and regions. The Module 1 of the Common Technical Document (CTD) of 10 countries were compared. Modules 2-5 of the CTDs of two regions and three countries were compared to the CTD of the US FDA. The application forms of eight countries were compared and the registration procedures of 134 importing countries were compared as well. The analysis indicates a high degree of divergence in numbering structure and content requirements. Possible interventions that would lead to significant improvements in registration efficiency include alignment in CTD numbering structure, a standardised model-application form, and better convergence of evaluation procedures. Copyright © 2018.

  18. 3D/3D registration of coronary CTA and biplane XA reconstructions for improved image guidance

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dibildox, Gerardo, E-mail: g.dibildox@erasmusmc.nl; Baka, Nora; Walsum, Theo van

    2014-09-15

    Purpose: The authors aim to improve image guidance during percutaneous coronary interventions of chronic total occlusions (CTO) by providing information obtained from computed tomography angiography (CTA) to the cardiac interventionist. To this end, the authors investigate a method to register a 3D CTA model to biplane reconstructions. Methods: The authors developed a method for registering preoperative coronary CTA with intraoperative biplane x-ray angiography (XA) images via 3D models of the coronary arteries. The models are extracted from the CTA and biplane XA images, and are temporally aligned based on CTA reconstruction phase and XA ECG signals. Rigid spatial alignment ismore » achieved with a robust probabilistic point set registration approach using Gaussian mixture models (GMMs). This approach is extended by including orientation in the Gaussian mixtures and by weighting bifurcation points. The method is evaluated on retrospectively acquired coronary CTA datasets of 23 CTO patients for which biplane XA images are available. Results: The Gaussian mixture model approach achieved a median registration accuracy of 1.7 mm. The extended GMM approach including orientation was not significantly different (P > 0.1) but did improve robustness with regards to the initialization of the 3D models. Conclusions: The authors demonstrated that the GMM approach can effectively be applied to register CTA to biplane XA images for the purpose of improving image guidance in percutaneous coronary interventions.« less

  19. Factors Associated with Behavior Change in Family Physicians After CME Presentation.

    ERIC Educational Resources Information Center

    Ferguson, Kristi J.; And Others

    1984-01-01

    Registrants of a four-day family practice refresher course responded to a survey assessing their reaction to a brief presentation recommending the use of penile anesthesia in newborn circumcision. The results suggest that evaluation of behavior change should consider attitudinal variables. (Author/MLW)

  20. Deformable planning CT to cone-beam CT image registration in head-and-neck cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hou Jidong; Guerrero, Mariana; Chen, Wenjuan

    2011-04-15

    Purpose: The purpose of this work was to implement and validate a deformable CT to cone-beam computed tomography (CBCT) image registration method in head-and-neck cancer to eventually facilitate automatic target delineation on CBCT. Methods: Twelve head-and-neck cancer patients underwent a planning CT and weekly CBCT during the 5-7 week treatment period. The 12 planning CT images (moving images) of these patients were registered to their weekly CBCT images (fixed images) via the symmetric force Demons algorithm and using a multiresolution scheme. Histogram matching was used to compensate for the intensity difference between the two types of images. Using nine knownmore » anatomic points as registration targets, the accuracy of the registration was evaluated using the target registration error (TRE). In addition, region-of-interest (ROI) contours drawn on the planning CT were morphed to the CBCT images and the volume overlap index (VOI) between registered contours and manually delineated contours was evaluated. Results: The mean TRE value of the nine target points was less than 3.0 mm, the slice thickness of the planning CT. Of the 369 target points evaluated for registration accuracy, the average TRE value was 2.6{+-}0.6 mm. The mean TRE for bony tissue targets was 2.4{+-}0.2 mm, while the mean TRE for soft tissue targets was 2.8{+-}0.2 mm. The average VOI between the registered and manually delineated ROI contours was 76.2{+-}4.6%, which is consistent with that reported in previous studies. Conclusions: The authors have implemented and validated a deformable image registration method to register planning CT images to weekly CBCT images in head-and-neck cancer cases. The accuracy of the TRE values suggests that they can be used as a promising tool for automatic target delineation on CBCT.« less

  1. Evaluation of MRI and cannabinoid type 1 receptor PET templates constructed using DARTEL for spatial normalization of rat brains

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kronfeld, Andrea; Müller-Forell, Wibke; Buchholz, Hans-Georg

    Purpose: Image registration is one prerequisite for the analysis of brain regions in magnetic-resonance-imaging (MRI) or positron-emission-tomography (PET) studies. Diffeomorphic anatomical registration through exponentiated Lie algebra (DARTEL) is a nonlinear, diffeomorphic algorithm for image registration and construction of image templates. The goal of this small animal study was (1) the evaluation of a MRI and calculation of several cannabinoid type 1 (CB1) receptor PET templates constructed using DARTEL and (2) the analysis of the image registration accuracy of MR and PET images to their DARTEL templates with reference to analytical and iterative PET reconstruction algorithms. Methods: Five male Sprague Dawleymore » rats were investigated for template construction using MRI and [{sup 18}F]MK-9470 PET for CB1 receptor representation. PET images were reconstructed using the algorithms filtered back-projection, ordered subset expectation maximization in 2D, and maximum a posteriori in 3D. Landmarks were defined on each MR image, and templates were constructed under different settings, i.e., based on different tissue class images [gray matter (GM), white matter (WM), and GM + WM] and regularization forms (“linear elastic energy,” “membrane energy,” and “bending energy”). Registration accuracy for MRI and PET templates was evaluated by means of the distance between landmark coordinates. Results: The best MRI template was constructed based on gray and white matter images and the regularization form linear elastic energy. In this case, most distances between landmark coordinates were <1 mm. Accordingly, MRI-based spatial normalization was most accurate, but results of the PET-based spatial normalization were quite comparable. Conclusions: Image registration using DARTEL provides a standardized and automatic framework for small animal brain data analysis. The authors were able to show that this method works with high reliability and validity. Using DARTEL templates together with nonlinear registration algorithms allows for accurate spatial normalization of combined MRI/PET or PET-only studies.« less

  2. Object-constrained meshless deformable algorithm for high speed 3D nonrigid registration between CT and CBCT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chen Ting; Kim, Sung; Goyal, Sharad

    2010-01-15

    Purpose: High-speed nonrigid registration between the planning CT and the treatment CBCT data is critical for real time image guided radiotherapy (IGRT) to improve the dose distribution and to reduce the toxicity to adjacent organs. The authors propose a new fully automatic 3D registration framework that integrates object-based global and seed constraints with the grayscale-based ''demons'' algorithm. Methods: Clinical objects were segmented on the planning CT images and were utilized as meshless deformable models during the nonrigid registration process. The meshless models reinforced a global constraint in addition to the grayscale difference between CT and CBCT in order to maintainmore » the shape and the volume of geometrically complex 3D objects during the registration. To expedite the registration process, the framework was stratified into hierarchies, and the authors used a frequency domain formulation to diffuse the displacement between the reference and the target in each hierarchy. Also during the registration of pelvis images, they replaced the air region inside the rectum with estimated pixel values from the surrounding rectal wall and introduced an additional seed constraint to robustly track and match the seeds implanted into the prostate. The proposed registration framework and algorithm were evaluated on 15 real prostate cancer patients. For each patient, prostate gland, seminal vesicle, bladder, and rectum were first segmented by a radiation oncologist on planning CT images for radiotherapy planning purpose. The same radiation oncologist also manually delineated the tumor volumes and critical anatomical structures in the corresponding CBCT images acquired at treatment. These delineated structures on the CBCT were only used as the ground truth for the quantitative validation, while structures on the planning CT were used both as the input to the registration method and the ground truth in validation. By registering the planning CT to the CBCT, a displacement map was generated. Segmented volumes in the CT images deformed using the displacement field were compared against the manual segmentations in the CBCT images to quantitatively measure the convergence of the shape and the volume. Other image features were also used to evaluate the overall performance of the registration. Results: The algorithm was able to complete the segmentation and registration process within 1 min, and the superimposed clinical objects achieved a volumetric similarity measure of over 90% between the reference and the registered data. Validation results also showed that the proposed registration could accurately trace the deformation inside the target volume with average errors of less than 1 mm. The method had a solid performance in registering the simulated images with up to 20 Hounsfield unit white noise added. Also, the side by side comparison with the original demons algorithm demonstrated its improved registration performance over the local pixel-based registration approaches. Conclusions: Given the strength and efficiency of the algorithm, the proposed method has significant clinical potential to accelerate and to improve the CBCT delineation and targets tracking in online IGRT applications.« less

  3. Simultaneous 3D–2D image registration and C-arm calibration: Application to endovascular image-guided interventions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mitrović, Uroš; Pernuš, Franjo; Likar, Boštjan

    Purpose: Three-dimensional to two-dimensional (3D–2D) image registration is a key to fusion and simultaneous visualization of valuable information contained in 3D pre-interventional and 2D intra-interventional images with the final goal of image guidance of a procedure. In this paper, the authors focus on 3D–2D image registration within the context of intracranial endovascular image-guided interventions (EIGIs), where the 3D and 2D images are generally acquired with the same C-arm system. The accuracy and robustness of any 3D–2D registration method, to be used in a clinical setting, is influenced by (1) the method itself, (2) uncertainty of initial pose of the 3Dmore » image from which registration starts, (3) uncertainty of C-arm’s geometry and pose, and (4) the number of 2D intra-interventional images used for registration, which is generally one and at most two. The study of these influences requires rigorous and objective validation of any 3D–2D registration method against a highly accurate reference or “gold standard” registration, performed on clinical image datasets acquired in the context of the intervention. Methods: The registration process is split into two sequential, i.e., initial and final, registration stages. The initial stage is either machine-based or template matching. The latter aims to reduce possibly large in-plane translation errors by matching a projection of the 3D vessel model and 2D image. In the final registration stage, four state-of-the-art intrinsic image-based 3D–2D registration methods, which involve simultaneous refinement of rigid-body and C-arm parameters, are evaluated. For objective validation, the authors acquired an image database of 15 patients undergoing cerebral EIGI, for which accurate gold standard registrations were established by fiducial marker coregistration. Results: Based on target registration error, the obtained success rates of 3D to a single 2D image registration after initial machine-based and template matching and final registration involving C-arm calibration were 36%, 73%, and 93%, respectively, while registration accuracy of 0.59 mm was the best after final registration. By compensating in-plane translation errors by initial template matching, the success rates achieved after the final stage improved consistently for all methods, especially if C-arm calibration was performed simultaneously with the 3D–2D image registration. Conclusions: Because the tested methods perform simultaneous C-arm calibration and 3D–2D registration based solely on anatomical information, they have a high potential for automation and thus for an immediate integration into current interventional workflow. One of the authors’ main contributions is also comprehensive and representative validation performed under realistic conditions as encountered during cerebral EIGI.« less

  4. Improvement of registration accuracy in accelerated partial breast irradiation using the point-based rigid-body registration algorithm for patients with implanted fiducial markers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Inoue, Minoru; Yoshimura, Michio, E-mail: myossy@kuhp.kyoto-u.ac.jp; Sato, Sayaka

    2015-04-15

    Purpose: To investigate image-registration errors when using fiducial markers with a manual method and the point-based rigid-body registration (PRBR) algorithm in accelerated partial breast irradiation (APBI) patients, with accompanying fiducial deviations. Methods: Twenty-two consecutive patients were enrolled in a prospective trial examining 10-fraction APBI. Titanium clips were implanted intraoperatively around the seroma in all patients. For image-registration, the positions of the clips in daily kV x-ray images were matched to those in the planning digitally reconstructed radiographs. Fiducial and gravity registration errors (FREs and GREs, respectively), representing resulting misalignments of the edge and center of the target, respectively, were comparedmore » between the manual and algorithm-based methods. Results: In total, 218 fractions were evaluated. Although the mean FRE/GRE values for the manual and algorithm-based methods were within 3 mm (2.3/1.7 and 1.3/0.4 mm, respectively), the percentages of fractions where FRE/GRE exceeded 3 mm using the manual and algorithm-based methods were 18.8%/7.3% and 0%/0%, respectively. Manual registration resulted in 18.6% of patients with fractions of FRE/GRE exceeding 5 mm. The patients with larger clip deviation had significantly more fractions showing large FRE/GRE using manual registration. Conclusions: For image-registration using fiducial markers in APBI, the manual registration results in more fractions with considerable registration error due to loss of fiducial objectivity resulting from their deviation. The authors recommend the PRBR algorithm as a safe and effective strategy for accurate, image-guided registration and PTV margin reduction.« less

  5. 49 CFR 390.203 - PRISM State registration/biennial updates.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... the Performance and Registration Information Systems Management (PRISM) program (authorized under... FEDERAL MOTOR CARRIER SAFETY REGULATIONS; GENERAL Unified Registration System § 390.203 PRISM State... procedures, provided the State has integrated the USDOT registration/update capability into its vehicle...

  6. 49 CFR 390.203 - PRISM State registration/biennial updates.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... the Performance and Registration Information Systems Management (PRISM) program (authorized under... FEDERAL MOTOR CARRIER SAFETY REGULATIONS; GENERAL Unified Registration System § 390.203 PRISM State... procedures, provided the State has integrated the USDOT registration/update capability into its vehicle...

  7. 75 FR 41968 - Re-Registration and Renewal of Aircraft Registration

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-07-20

    ... the use of the second or ``Pink Copy'' of the application for registration for a reasonable period of... under ``Pink Copy'' temporary authority at any time if an application for registration is made. Due to... reference to the ``pink copy'' of the Aircraft Registration Application. V. Miscellaneous Comments A. Re...

  8. Pesticide Registration Manual: Chapter 17 - State Regulatory Authority

    EPA Pesticide Factsheets

    FIFRA authorizes states to issue Experimental Use Permits, Special Local Needs registrations, and to apply for Emergency Exemptions under specific conditions. This chapter provides detailed information relevant to state actions under FIFRA.

  9. Position tracking of moving liver lesion based on real-time registration between 2D ultrasound and 3D preoperative images

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Weon, Chijun; Hyun Nam, Woo; Lee, Duhgoon

    Purpose: Registration between 2D ultrasound (US) and 3D preoperative magnetic resonance (MR) (or computed tomography, CT) images has been studied recently for US-guided intervention. However, the existing techniques have some limits, either in the registration speed or the performance. The purpose of this work is to develop a real-time and fully automatic registration system between two intermodal images of the liver, and subsequently an indirect lesion positioning/tracking algorithm based on the registration result, for image-guided interventions. Methods: The proposed position tracking system consists of three stages. In the preoperative stage, the authors acquire several 3D preoperative MR (or CT) imagesmore » at different respiratory phases. Based on the transformations obtained from nonrigid registration of the acquired 3D images, they then generate a 4D preoperative image along the respiratory phase. In the intraoperative preparatory stage, they properly attach a 3D US transducer to the patient’s body and fix its pose using a holding mechanism. They then acquire a couple of respiratory-controlled 3D US images. Via the rigid registration of these US images to the 3D preoperative images in the 4D image, the pose information of the fixed-pose 3D US transducer is determined with respect to the preoperative image coordinates. As feature(s) to use for the rigid registration, they may choose either internal liver vessels or the inferior vena cava. Since the latter is especially useful in patients with a diffuse liver disease, the authors newly propose using it. In the intraoperative real-time stage, they acquire 2D US images in real-time from the fixed-pose transducer. For each US image, they select candidates for its corresponding 2D preoperative slice from the 4D preoperative MR (or CT) image, based on the predetermined pose information of the transducer. The correct corresponding image is then found among those candidates via real-time 2D registration based on a gradient-based similarity measure. Finally, if needed, they obtain the position information of the liver lesion using the 3D preoperative image to which the registered 2D preoperative slice belongs. Results: The proposed method was applied to 23 clinical datasets and quantitative evaluations were conducted. With the exception of one clinical dataset that included US images of extremely low quality, 22 datasets of various liver status were successfully applied in the evaluation. Experimental results showed that the registration error between the anatomical features of US and preoperative MR images is less than 3 mm on average. The lesion tracking error was also found to be less than 5 mm at maximum. Conclusions: A new system has been proposed for real-time registration between 2D US and successive multiple 3D preoperative MR/CT images of the liver and was applied for indirect lesion tracking for image-guided intervention. The system is fully automatic and robust even with images that had low quality due to patient status. Through visual examinations and quantitative evaluations, it was verified that the proposed system can provide high lesion tracking accuracy as well as high registration accuracy, at performance levels which were acceptable for various clinical applications.« less

  10. Assessing Significance in Continuing Education: A Needed Adition to Productivity.

    ERIC Educational Resources Information Center

    Burnham, Byron R.

    1986-01-01

    A process whereby continuing education administrators can quantitatively measure FTEs (full-time equivalency), courses, registration, costs, and student hours and relate these measurements to staff productivity is evaluated and its limitations explored. The author also presents a framework of accounting for adult education productivity and values.…

  11. 21 CFR 1311.45 - Requirements for registrants that allow powers of attorney to obtain CSOS digital certificates...

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... attorney to obtain CSOS digital certificates under their DEA registration. 1311.45 Section 1311.45 Food and... registrants that allow powers of attorney to obtain CSOS digital certificates under their DEA registration. (a) A registrant that grants power of attorney must report to the DEA Certification Authority within 6...

  12. 21 CFR 1301.13 - Application for registration; time for application; expiration date; registration for independent...

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... conduct such research only to the extent expressly authorized under State statute. A pharmacist may... expressly authorized under state statute. A pharmacist may manufacture an aqueous or oleaginous solution or...

  13. The Conduct and Reporting of Child Health Research: An Analysis of Randomized Controlled Trials Published in 2012 and Evaluation of Change over 5 Years.

    PubMed

    Gates, Allison; Hartling, Lisa; Vandermeer, Ben; Caldwell, Patrina; Contopoulos-Ioannidis, Despina G; Curtis, Sarah; Fernandes, Ricardo M; Klassen, Terry P; Williams, Katrina; Dyson, Michele P

    2018-02-01

    For child health randomized controlled trials (RCTs) published in 2012, we aimed to describe design and reporting characteristics and evaluate changes since 2007; assess the association between trial design and registration and risk of bias (RoB); and assess the association between RoB and effect size. For 300 RCTs, we extracted design and reporting characteristics and assessed RoB. We assessed 5-year changes in design and reporting (based on 300 RCTs we had previously analyzed) using the Fisher exact test. We tested for associations between design and reporting characteristics and overall RoB and registration using the Fisher exact, Cochran-Armitage, Kruskal-Wallis, and Jonckheere-Terpstra tests. We pooled effect sizes and tested for differences by RoB using the χ 2 test for subgroups in meta-analysis. The 2012 and 2007 RCTs differed with respect to many design and reporting characteristics. From 2007 to 2012, RoB did not change for random sequence generation and improved for allocation concealment (P < .001). Fewer 2012 RCTs were rated high overall RoB and more were rated unclear (P = .03). Only 7.3% of 2012 RCTs were rated low overall RoB. Trial registration doubled from 2007 to 2012 (23% to 46%) (P < .001) and was associated with lower RoB (P = .009). Effect size did not differ by RoB (P = .43) CONCLUSIONS: Random sequence generation and allocation concealment were not often reported, and selective reporting was prevalent. Measures to increase trialists' awareness and application of existing reporting guidance, and the prospective registration of RCTs is needed to improve the trustworthiness of findings from this field. Copyright © 2017 The Author(s). Published by Elsevier Inc. All rights reserved.

  14. [Discussion on Technical Evaluation for Medical Device Registration Material].

    PubMed

    Chu, Yungao; Qian, Hong; Zhu, Yingfeng

    2017-07-30

    This article first introduces the main contents of the requirements for medical device registration. Secondly, this article chooses the vertebral forming surgery system as an example to discuss the technical evaluation for the registration research material. The article hopes to provide a reference for the applicant who prepare the registration material and the technical evaluator who make the evaluation for the medical device registration.

  15. Highway Safety Program Manual: Volume 2: Motor Vehicle Registration.

    ERIC Educational Resources Information Center

    National Highway Traffic Safety Administration (DOT), Washington, DC.

    Volume 2 of the 19-volume Highway Safety Program Manual (which provides guidance to State and local governments on preferred highway safety practices) describes the purposes and specific objectives of motor vehicle registration. Federal authority for vehicle registration and general policies regarding vehicle registration systems are outlined.…

  16. 32 CFR 1651.4 - Review by district appeal board.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... personal appearance and such summary shall be placed in the registrant's file. (n) A district appeal board... registrant's file; and (2) Oral statements by the registrant during the registrant's personal appearance; and... compensated employee authorized to perform the administrative duties of the board shall review the file to...

  17. Improving alignment in Tract-based spatial statistics: evaluation and optimization of image registration.

    PubMed

    de Groot, Marius; Vernooij, Meike W; Klein, Stefan; Ikram, M Arfan; Vos, Frans M; Smith, Stephen M; Niessen, Wiro J; Andersson, Jesper L R

    2013-08-01

    Anatomical alignment in neuroimaging studies is of such importance that considerable effort is put into improving the registration used to establish spatial correspondence. Tract-based spatial statistics (TBSS) is a popular method for comparing diffusion characteristics across subjects. TBSS establishes spatial correspondence using a combination of nonlinear registration and a "skeleton projection" that may break topological consistency of the transformed brain images. We therefore investigated feasibility of replacing the two-stage registration-projection procedure in TBSS with a single, regularized, high-dimensional registration. To optimize registration parameters and to evaluate registration performance in diffusion MRI, we designed an evaluation framework that uses native space probabilistic tractography for 23 white matter tracts, and quantifies tract similarity across subjects in standard space. We optimized parameters for two registration algorithms on two diffusion datasets of different quality. We investigated reproducibility of the evaluation framework, and of the optimized registration algorithms. Next, we compared registration performance of the regularized registration methods and TBSS. Finally, feasibility and effect of incorporating the improved registration in TBSS were evaluated in an example study. The evaluation framework was highly reproducible for both algorithms (R(2) 0.993; 0.931). The optimal registration parameters depended on the quality of the dataset in a graded and predictable manner. At optimal parameters, both algorithms outperformed the registration of TBSS, showing feasibility of adopting such approaches in TBSS. This was further confirmed in the example experiment. Copyright © 2013 Elsevier Inc. All rights reserved.

  18. Evaluation of five diffeomorphic image registration algorithms for mouse brain magnetic resonance microscopy.

    PubMed

    Fu, Zhenrong; Lin, Lan; Tian, Miao; Wang, Jingxuan; Zhang, Baiwen; Chu, Pingping; Li, Shaowu; Pathan, Muhammad Mohsin; Deng, Yulin; Wu, Shuicai

    2017-11-01

    The development of genetically engineered mouse models for neuronal diseases and behavioural disorders have generated a growing need for small animal imaging. High-resolution magnetic resonance microscopy (MRM) provides powerful capabilities for noninvasive studies of mouse brains, while avoiding some limits associated with the histological procedures. Quantitative comparison of structural images is a critical step in brain imaging analysis, which highly relies on the performance of image registration techniques. Nowadays, there is a mushrooming growth of human brain registration algorithms, while fine-tuning of those algorithms for mouse brain MRMs is rarely addressed. Because of their topology preservation property and outstanding performance in human studies, diffeomorphic transformations have become popular in computational anatomy. In this study, we specially tuned five diffeomorphic image registration algorithms [DARTEL, geodesic shooting, diffeo-demons, SyN (Greedy-SyN and geodesic-SyN)] for mouse brain MRMs and evaluated their performance using three measures [volume overlap percentage (VOP), residual intensity error (RIE) and surface concordance ratio (SCR)]. Geodesic-SyN performed significantly better than the other methods according to all three different measures. These findings are important for the studies on structural brain changes that may occur in wild-type and transgenic mouse brains. © 2017 The Authors Journal of Microscopy © 2017 Royal Microscopical Society.

  19. Unstaffed trail registration compliance in a backcountry recreation area.

    Treesearch

    Earl C. Leatherberry; David W. Lime

    1981-01-01

    Presents findings from a study in Michigan's Upper Peninsula to evaluate the effectiveness of unstaffed trail registration stations to obtain recreation use information. Two registration approaches were evaluated: (1) self-issued voluntary registration form, and (2) self-issued mandatory registration form. The paper also cites factors influencing registration...

  20. Markerless laser registration in image-guided oral and maxillofacial surgery.

    PubMed

    Marmulla, Rüdiger; Lüth, Tim; Mühling, Joachim; Hassfeld, Stefan

    2004-07-01

    The use of registration markers in computer-assisted surgery is combined with high logistic costs and efforts. Markerless patient registration using laser scan surface registration techniques is a new challenging method. The present study was performed to evaluate the clinical accuracy in finding defined target points within the surgical site after markerless patient registration in image-guided oral and maxillofacial surgery. Twenty consecutive patients with different cranial diseases were scheduled for computer-assisted surgery. Data set alignment between the surgical site and the computed tomography (CT) data set was performed by markerless laser scan surface registration of the patient's face. Intraoral rigidly attached registration markers were used as target points, which had to be detected by an infrared pointer. The Surgical Segment Navigator SSN++ has been used for all procedures. SSN++ is an investigative product based on the SSN system that had previously been developed by the presenting authors with the support of Carl Zeiss (Oberkochen, Germany). SSN++ is connected to a Polaris infrared camera (Northern Digital, Waterloo, Ontario, Canada) and to a Minolta VI 900 3D digitizer (Tokyo, Japan) for high-resolution laser scanning. Minimal differences in shape between the laser scan surface and the surface generated from the CT data set could be detected. Nevertheless, high-resolution laser scan of the skin surface allows for a precise patient registration (mean deviation 1.1 mm, maximum deviation 1.8 mm). Radiation load, logistic costs, and efforts arising from the planning of computer-assisted surgery of the head can be reduced because native (markerless) CT data sets can be used for laser scan-based surface registration.

  1. Tissue-Point Motion Tracking in the Tongue from Cine MRI and Tagged MRI

    ERIC Educational Resources Information Center

    Woo, Jonghye; Stone, Maureen; Suo, Yuanming; Murano, Emi Z.; Prince, Jerry L.

    2014-01-01

    Purpose: Accurate tissue motion tracking within the tongue can help professionals diagnose and treat vocal tract--related disorders, evaluate speech quality before and after surgery, and conduct various scientific studies. The authors compared tissue tracking results from 4 widely used deformable registration (DR) methods applied to cine magnetic…

  2. Biosafety evaluation of recombinant live oral bacterial vaccines in the context of European regulation.

    PubMed

    Favre, Didier; Viret, Jean-François

    2006-05-01

    Live bacterial vaccines represent a highly valid preventive strategy in the fight against infectious disease. However, the road from research to market is peppered with hurdles, one of which is the requirement for high biosafety characteristics, which the candidate vaccine has to display. In Europe, the European Agency for the evaluation of medicinal products (EMEA) is the relevant authority regulating the licensure of genetically engineered vaccines. For this purpose, the agency may rely on several directives and guidelines defined in the past 15 years. As for live vaccines containing genetically modified organisms (GMOs) susceptible to be released into the environment, Directive 2001/18/EC determines the framework and principles of an environmental risk assessment (ERA) process, the results of which constitute an important section of the vaccine registration package submitted to registration authorities. In this article, we address the implications of current European regulations for the approval of live oral bacterial vaccines with emphasis on the assessment of potential risks associated with environmental release. Biosafety aspects of already registered and some promising live bacterial vaccine strains will be briefly discussed.

  3. 24 CFR 5.905 - What special authority is there to obtain access to sex offender registration information?

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... obtain access to sex offender registration information? 5.905 Section 5.905 Housing and Urban Development... access to sex offender registration information? (a) PHA obligation to obtain sex offender registration... applying for admission to any federally assisted housing program is subject to a lifetime sex offender...

  4. 24 CFR 5.905 - What special authority is there to obtain access to sex offender registration information?

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... obtain access to sex offender registration information? 5.905 Section 5.905 Housing and Urban Development... access to sex offender registration information? (a) PHA obligation to obtain sex offender registration... applying for admission to any federally assisted housing program is subject to a lifetime sex offender...

  5. 24 CFR 5.905 - What special authority is there to obtain access to sex offender registration information?

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... obtain access to sex offender registration information? 5.905 Section 5.905 Housing and Urban Development... access to sex offender registration information? (a) PHA obligation to obtain sex offender registration... applying for admission to any federally assisted housing program is subject to a lifetime sex offender...

  6. 24 CFR 5.905 - What special authority is there to obtain access to sex offender registration information?

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... obtain access to sex offender registration information? 5.905 Section 5.905 Housing and Urban Development... access to sex offender registration information? (a) PHA obligation to obtain sex offender registration... applying for admission to any federally assisted housing program is subject to a lifetime sex offender...

  7. 24 CFR 5.905 - What special authority is there to obtain access to sex offender registration information?

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... obtain access to sex offender registration information? 5.905 Section 5.905 Housing and Urban Development... access to sex offender registration information? (a) PHA obligation to obtain sex offender registration... applying for admission to any federally assisted housing program is subject to a lifetime sex offender...

  8. Error estimation of deformable image registration of pulmonary CT scans using convolutional neural networks.

    PubMed

    Eppenhof, Koen A J; Pluim, Josien P W

    2018-04-01

    Error estimation in nonlinear medical image registration is a nontrivial problem that is important for validation of registration methods. We propose a supervised method for estimation of registration errors in nonlinear registration of three-dimensional (3-D) images. The method is based on a 3-D convolutional neural network that learns to estimate registration errors from a pair of image patches. By applying the network to patches centered around every voxel, we construct registration error maps. The network is trained using a set of representative images that have been synthetically transformed to construct a set of image pairs with known deformations. The method is evaluated on deformable registrations of inhale-exhale pairs of thoracic CT scans. Using ground truth target registration errors on manually annotated landmarks, we evaluate the method's ability to estimate local registration errors. Estimation of full domain error maps is evaluated using a gold standard approach. The two evaluation approaches show that we can train the network to robustly estimate registration errors in a predetermined range, with subvoxel accuracy. We achieved a root-mean-square deviation of 0.51 mm from gold standard registration errors and of 0.66 mm from ground truth landmark registration errors.

  9. 17 CFR 200.30-18 - Delegation of authority to Director of the Office of Compliance Inspections and Examinations.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ...-1 et seq.): (1) Pursuant to Section 203(h) of the Advisers Act (15 U.S.C.80b-3(h)), to authorize the... 15B(a) of the Act (15 U.S.C. 78o-4(a)): (i) To authorize the issuance of orders granting registration....S.C. 78o-4(c)): (i) To authorize the issuance of orders canceling registrations of municipal...

  10. 17 CFR 200.30-18 - Delegation of authority to Director of the Office of Compliance Inspections and Examinations.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ...-1 et seq.): (1) Pursuant to Section 203(h) of the Advisers Act (15 U.S.C.80b-3(h)), to authorize the... 15B(a) of the Act (15 U.S.C. 78o-4(a)): (i) To authorize the issuance of orders granting registration....S.C. 78o-4(c)): (i) To authorize the issuance of orders canceling registrations of municipal...

  11. 21 CFR 1311.20 - Coordinators for CSOS digital certificate holders.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... digital certificates issued under that registrant's DEA registration. While the coordinator will be the main point of contact between one or more DEA registered locations and the CSOS Certification Authority... application that the DEA Certification Authority provides and submit the following: (1) Two copies of...

  12. 75 FR 34757 - Information Collection Sent to the Office of Management and Budget (OMB) for Approval; OMB...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-06-18

    ...-0137; Applications for Single Use Permits and Registration of Production Facilities (CITES) AGENCY...-0137. Title: Applications for Single Use Permits and Registration of Production Facilities (CITES), 50... import or export of CITES-listed species, the Management Authority and Scientific Authority must make...

  13. 31 CFR 360.6 - Authorized forms of registration.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 31 Money and Finance:Treasury 2 2013-07-01 2013-07-01 false Authorized forms of registration. 360.6 Section 360.6 Money and Finance: Treasury Regulations Relating to Money and Finance (Continued... Pension Fund of Safety Manufacturing Company, U/A with the company, dated March 31, 1996, 12-3456789...

  14. 31 CFR 360.6 - Authorized forms of registration.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 31 Money and Finance:Treasury 2 2011-07-01 2011-07-01 false Authorized forms of registration. 360.6 Section 360.6 Money and Finance: Treasury Regulations Relating to Money and Finance (Continued... Pension Fund of Safety Manufacturing Company, U/A with the company, dated March 31, 1996, 12-3456789...

  15. 31 CFR 315.7 - Authorized forms of registration.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 31 Money and Finance:Treasury 2 2012-07-01 2012-07-01 false Authorized forms of registration. 315.7 Section 315.7 Money and Finance: Treasury Regulations Relating to Money and Finance (Continued... omitted. Examples: Tenth National Bank, trustee of Pension Fund of Safety Manufacturing Company, U/A with...

  16. 31 CFR 360.6 - Authorized forms of registration.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 31 Money and Finance:Treasury 2 2012-07-01 2012-07-01 false Authorized forms of registration. 360.6 Section 360.6 Money and Finance: Treasury Regulations Relating to Money and Finance (Continued... Pension Fund of Safety Manufacturing Company, U/A with the company, dated March 31, 1996, 12-3456789...

  17. 31 CFR 353.7 - Authorized forms of registration.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 31 Money and Finance: Treasury 2 2014-07-01 2014-07-01 false Authorized forms of registration. 353.7 Section 353.7 Money and Finance: Treasury Regulations Relating to Money and Finance (Continued... limited term, their names may be omitted. Examples: Tenth National Bank, trustee of Pension Fund of Safety...

  18. 31 CFR 315.7 - Authorized forms of registration.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 31 Money and Finance:Treasury 2 2013-07-01 2013-07-01 false Authorized forms of registration. 315.7 Section 315.7 Money and Finance: Treasury Regulations Relating to Money and Finance (Continued... omitted. Examples: Tenth National Bank, trustee of Pension Fund of Safety Manufacturing Company, U/A with...

  19. 31 CFR 353.7 - Authorized forms of registration.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 31 Money and Finance:Treasury 2 2013-07-01 2013-07-01 false Authorized forms of registration. 353.7 Section 353.7 Money and Finance: Treasury Regulations Relating to Money and Finance (Continued... limited term, their names may be omitted. Examples: Tenth National Bank, trustee of Pension Fund of Safety...

  20. 31 CFR 360.6 - Authorized forms of registration.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 31 Money and Finance: Treasury 2 2014-07-01 2014-07-01 false Authorized forms of registration. 360.6 Section 360.6 Money and Finance: Treasury Regulations Relating to Money and Finance (Continued... Pension Fund of Safety Manufacturing Company, U/A with the company, dated March 31, 1996, 12-3456789...

  1. 31 CFR 315.7 - Authorized forms of registration.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 31 Money and Finance: Treasury 2 2014-07-01 2014-07-01 false Authorized forms of registration. 315.7 Section 315.7 Money and Finance: Treasury Regulations Relating to Money and Finance (Continued... omitted. Examples: Tenth National Bank, trustee of Pension Fund of Safety Manufacturing Company, U/A with...

  2. 31 CFR 353.7 - Authorized forms of registration.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 31 Money and Finance:Treasury 2 2012-07-01 2012-07-01 false Authorized forms of registration. 353.7 Section 353.7 Money and Finance: Treasury Regulations Relating to Money and Finance (Continued... limited term, their names may be omitted. Examples: Tenth National Bank, trustee of Pension Fund of Safety...

  3. 9 CFR 201.86 - Brand inspection: Application for authorization, registration and filing of schedules, reciprocal...

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... authorization, registration and filing of schedules, reciprocal arrangements, and maintenance of identity of... and filing of schedules, reciprocal arrangements, and maintenance of identity of consignments. (a... and will not result in duplication of charges or services. (d) Maintenance of identity of consignments...

  4. 9 CFR 201.86 - Brand inspection: Application for authorization, registration and filing of schedules, reciprocal...

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... authorization, registration and filing of schedules, reciprocal arrangements, and maintenance of identity of... and filing of schedules, reciprocal arrangements, and maintenance of identity of consignments. (a... and will not result in duplication of charges or services. (d) Maintenance of identity of consignments...

  5. 9 CFR 201.86 - Brand inspection: Application for authorization, registration and filing of schedules, reciprocal...

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... authorization, registration and filing of schedules, reciprocal arrangements, and maintenance of identity of... and filing of schedules, reciprocal arrangements, and maintenance of identity of consignments. (a... and will not result in duplication of charges or services. (d) Maintenance of identity of consignments...

  6. 21 CFR 1311.25 - Requirements for obtaining a CSOS digital certificate.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... attorney for a registrant must complete the application that the DEA Certification Authority provides and... photographic identification. (2) A current listing of DEA registrations for which the individual has authority... agrees to the statement of subscriber obligations that DEA provides. (b) The applicant must provide the...

  7. 47 CFR 90.121 - Canadian registration.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 5 2010-10-01 2010-10-01 false Canadian registration. 90.121 Section 90.121 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES PRIVATE LAND MOBILE RADIO SERVICES Applications and Authorizations § 90.121 Canadian registration. Form 410 shall be...

  8. 9 CFR 201.86 - Brand inspection: Application for authorization, registration and filing of schedules, reciprocal...

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 9 Animals and Animal Products 2 2010-01-01 2010-01-01 false Brand inspection: Application for... STOCKYARDS ACT Inspection of Brands § 201.86 Brand inspection: Application for authorization, registration... in which branding or marking of livestock as a means of establishing ownership prevails by custom or...

  9. 78 FR 78923 - Comparability Determination for the European Union: Certain Entity-Level Requirements

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-12-27

    ... authority to support and enforce its oversight of the registrant. In this context, comparable does not... jurisdiction's authority to support and enforce its oversight of the registrant.\\23\\ \\23\\ 78 FR 45343. In... with respect to their swaps activities,\\41\\ which is critical to effective systemic risk management for...

  10. 40 CFR 162.155 - Suspension of State registration authority.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Administrator may suspend a State's registration authority due to lack of, or failure to exercise, adequate...) If the Administrator finds that a State is not capable of exercising, or has failed to exercise... State fails to exercise the controls specified in paragraph (b)(1) of this section, or if the State...

  11. GT-57633 catalogue of Martian impact craters developed for evaluation of crater detection algorithms

    NASA Astrophysics Data System (ADS)

    Salamunićcar, Goran; Lončarić, Sven

    2008-12-01

    Crater detection algorithms (CDAs) are an important subject of the recent scientific research. A ground truth (GT) catalogue, which contains the locations and sizes of known craters, is important for the evaluation of CDAs in a wide range of CDA applications. Unfortunately, previous catalogues of craters by other authors cannot be easily used as GT. In this paper, we propose a method for integration of several existing catalogues to obtain a new craters catalogue. The methods developed and used during this work on the GT catalogue are: (1) initial screening of used catalogues; (2) evaluation of self-consistency of used catalogues; (3) initial registration from three different catalogues; (4) cross-evaluation of used catalogues; (5) additional registrations and registrations from additional catalogues; and (6) fine-tuning and registration with additional data-sets. During this process, all craters from all major currently available manually assembled catalogues were processed, including catalogues by Barlow, Rodionova, Boyce, Kuzmin, and our previous work. Each crater from the GT catalogue contains references to crater(s) that are used for its registration. This provides direct access to all properties assigned to craters from the used catalogues, which can be of interest even to those scientists that are not directly interested in CDAs. Having all these craters in a single catalogue also provides a good starting point for searching for craters still not catalogued manually, which is also expected to be one of the challenges of CDAs. The resulting new GT catalogue contains 57,633 craters, significantly more than any previous catalogue. From this point of view, GT-57633 catalogue is currently the most complete catalogue of large Martian impact craters. Additionally, each crater from the resulting GT-57633 catalogue is aligned with MOLA topography and, during the final review phase, additionally registered/aligned with 1/256° THEMIS-DIR, 1/256° MDIM and 1/256° MOC data-sets. Accordingly, the resulting GT-57633 catalogue can successfully be used as a part of the framework for evaluation of CDAs.

  12. 75 FR 78734 - R & M Sales Company, Inc.; Revocation of Registration

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-12-16

    ... revocation of Respondent's DEA Certificate of Registration, 004413RAY, which authorizes it to distribute List I chemicals, as well as the denial of any pending application to renew its registration, on the... Respondent distributes pseudoephedrine and ephedrine products in both tablet and gel-capsule form, which are...

  13. 26 CFR 48.4222(c)-1 - Revocation or suspension of registration.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... (CONTINUED) MISCELLANEOUS EXCISE TAXES MANUFACTURERS AND RETAILERS EXCISE TAXES Exemptions, Registration, Etc... International Operations, as the case may be, is authorized to revoke or temporarily suspend, upon written notice, the registration of any person and the right of such person to sell or purchase articles tax free...

  14. 76 FR 51430 - Roots Pharmaceuticals, Inc.; Revocation of Registration

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-18

    ... Registration BR9610571, which authorizes it to dispense controlled substances as a retail pharmacy, on the ground that Registrant's state pharmacy and controlled substance licenses had expired on September 30... retail pharmacy, at the registered location of 12 W 100N, Suite 201B, American Fork, Utah. GX A...

  15. 14 CFR 13.19 - Certificate action.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... any civil airman. Under section 501(e) of the FA Act, any Certificate of Aircraft Registration may be... revoking that certificate. This authority as to aircraft found ineligible for registration is also... Aircraft Registration is affected by an order issued under this section. [Doc. No. 13-14, 44 FR 63723, Nov...

  16. 14 CFR 13.19 - Certificate action.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... any civil airman. Under section 501(e) of the FA Act, any Certificate of Aircraft Registration may be... revoking that certificate. This authority as to aircraft found ineligible for registration is also... Aircraft Registration is affected by an order issued under this section. [Doc. No. 13-14, 44 FR 63723, Nov...

  17. 14 CFR 13.19 - Certificate action.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... any civil airman. Under section 501(e) of the FA Act, any Certificate of Aircraft Registration may be... revoking that certificate. This authority as to aircraft found ineligible for registration is also... Aircraft Registration is affected by an order issued under this section. [Doc. No. 13-14, 44 FR 63723, Nov...

  18. ResearchMatch: A National Registry to Recruit Volunteers for Clinical Research

    PubMed Central

    Harris, Paul A.; Scott, Kirstin W; Lebo, Laurie; Hassan, NikNik; Lighter, Chad; Pulley, Jill

    2013-01-01

    The authors designed ResearchMatch, a disease-neutral, web-based recruitment registry to help match individuals who wish to participate in clinical research studies with researchers actively searching for volunteers throughout the United States. In this article, they describe ResearchMatch’s stakeholders, workflow model, technical infrastructure, and, for the registry’s first 19 months of operation, utilization metrics. Having launched volunteer registration tools in November 2009 and researcher registration tools in March 2010, ResearchMatch had, as of June 2011, registered 15,871 volunteer participants from all 50 states. The registry was created as a collaborative project for institutions in the Clinical and Translational Science Awards (CTSA) consortium. Also as of June 2011, a total of 751 researchers from 61 participating CTSA institutions had registered to use the tool to recruit participants into 540 active studies and trials. ResearchMatch has proven successful in connecting volunteers with researchers, and the authors are currently evaluating regulatory and workflow options to open access to researchers at non-CTSA institutions. PMID:22104055

  19. [Bioequivalence of dermatological topical medicines:the Brazilian scenario and the challenges for health surveillance].

    PubMed

    Soares, Kelen Carine Costa; Moraes, Marcelo Vogler; Gelfuso, Guilherme Martins; Gratieri, Taís

    2015-11-01

    The comparative evaluation required for the registration of generic topical medicines in Brazil is conducted by means of a pharmaceutical equivalence study, which merely assesses the physical/chemical and microbiological parameters of the formulations. At the international level, clinical or pharmacodynamic studies are now being required to prove the efficacy and safety of semisolid topical generic formulations. This work presents a comparison of the different requirements for the registration of topical formulations, taking into consideration the various regulatory authorities, and presents a survey of topical medicines registered in Brazil prior to 2013. The survey revealed that in comparison with the USA there were many more copies of these formulations registered in Brazil. This fact, together with the large number of studies in the literature showing the lack of bioequivalence of topical medication, is clear proof of the major importance of the need to realign Brazilian legislation with respect to the technical requirements for the registration of generic and similar medication for dermatological topical application in Brazil.

  20. A Greedy Algorithm for Brain MRI's Registration.

    PubMed

    Chesseboeuf, Clément

    2016-12-01

    This document presents a non-rigid registration algorithm for the use of brain magnetic resonance (MR) images comparison. More precisely, we want to compare pre-operative and post-operative MR images in order to assess the deformation due to a surgical removal. The proposed algorithm has been studied in Chesseboeuf et al. ((Non-rigid registration of magnetic resonance imaging of brain. IEEE, 385-390. doi: 10.1109/IPTA.2015.7367172 , 2015), following ideas of Trouvé (An infinite dimensional group approach for physics based models in patterns recognition. Technical Report DMI Ecole Normale Supérieure, Cachan, 1995), in which the author introduces the algorithm within a very general framework. Here we recalled this theory from a practical point of view. The emphasis is on illustrations and description of the numerical procedure. Our version of the algorithm is associated with a particular matching criterion. Then, a section is devoted to the description of this object. In the last section we focus on the construction of a statistical method of evaluation.

  1. Validation of The Scenarios Designed For The Eu Registration of Pesticides

    NASA Astrophysics Data System (ADS)

    Piñeros Garcet, J. D.; de Nie, D.; Vanclooster, M.; Tiktak, A.; Klein, M.

    As part of recent efforts to harmonise registration procedures for pesticides within the EU, a set of uniform principles were developed, setting out the detailed evaluation and decision making criteria for pesticide registration. The EU directive 91/414/EEC places great importance on the use of validated models to calculate Predicted Envi- ronmental Concentrations (PECs), as a basis for assessing the environmental risks and health effects. To be used in a harmonised registration process, the quality of PEC modelling needs to be assured. Quality assurance of mathematical modelling implies, amongst others, the validation of the environmental modelling scenarios. The FOrum for the CO-ordination of pesticide fate models and their USe (FOCUS), is the cur- rent platform where common modelling methodologies are designed and subjected for approval to the European authorities. In 2000, the FOCUS groundwater scenarios working group defined the procedures for realising tier 1 PEC groundwater calcula- tions for the active substances of plant protection products at the pan-european level. The procedures and guidelines were approved by the Standing Committee on Plant Health, and are now recommended for tier 1 PEC groundwater calculations in the reg-istration dossier. Yet, the working group also identified a range of uncertainties related to the validity of the present leaching scenarios. To mitigate some of these problems,the EU R&D project APECOP was designed and approved for support in the frame-work of the EU-FP5-Quality of Life Programme. One of the objectives of the project is to evaluate the appropriateness of the current Tier 1 groundwater scenarios. In this paper, we summarise the methodology and results of the scenarios validation.

  2. Feasibility of Multimodal Deformable Registration for Head and Neck Tumor Treatment Planning

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fortunati, Valerio, E-mail: v.fortunati@erasmusmc.nl; Verhaart, René F.; Angeloni, Francesco

    2014-09-01

    Purpose: To investigate the feasibility of using deformable registration in clinical practice to fuse MR and CT images of the head and neck for treatment planning. Method and Materials: A state-of-the-art deformable registration algorithm was optimized, evaluated, and compared with rigid registration. The evaluation was based on manually annotated anatomic landmarks and regions of interest in both modalities. We also developed a multiparametric registration approach, which simultaneously aligns T1- and T2-weighted MR sequences to CT. This was evaluated and compared with single-parametric approaches. Results: Our results show that deformable registration yielded a better accuracy than rigid registration, without introducing unrealisticmore » deformations. For deformable registration, an average landmark alignment of approximatively 1.7 mm was obtained. For all the regions of interest excluding the cerebellum and the parotids, deformable registration provided a median modified Hausdorff distance of approximatively 1 mm. Similar accuracies were obtained for the single-parameter and multiparameter approaches. Conclusions: This study demonstrates that deformable registration of head-and-neck CT and MR images is feasible, with overall a significanlty higher accuracy than for rigid registration.« less

  3. The timing of introduction of pharmaceutical innovations in seven European countries.

    PubMed

    Westerling, Ragnar; Westin, Marcus; McKee, Martin; Hoffmann, Rasmus; Plug, Iris; Rey, Grégoire; Jougla, Eric; Lang, Katrin; Pärna, Kersti; Alfonso, José L; Mackenbach, Johan P

    2014-08-01

    Differences in the performance of medical care may be due to variation in the introduction and diffusion of medical innovations. The objective of this paper is to compare seven European countries (United Kingdom, the Netherlands, West Germany, France, Spain, Estonia and Sweden) with regard to the year of introduction of six specific pharmaceutical innovations (antiretroviral drugs, cimetidine, tamoxifen, cisplatin, oxalaplatin and cyclosporin) that may have had important population health impacts. We collected information on introduction and further diffusion of drugs using searches in the national and international literature, and questionnaires to national informants. We combined various sources of information, both official years of registration and other indicators of introduction (clinical trials, guidelines, evaluation reports, sales statistics). The total length of the period between first and last introduction varied between 8 years for antiretroviral drugs and 22 years for cisplatin. Introduction in Estonia was generally delayed until the 1990s. The average time lags were smallest in France (2.2 years), United Kingdom (2.8 years) and the Netherlands (3.5 years). Similar rank orders were seen for year of registration suggesting that introduction lags are not only explained by differences in the process of registration. We discuss possible reasons for these between-country differences and implications for the evaluation of medical care. © 2014 The Authors. Journal of Evaluation in Clinical Practice published by John Wiley & Sons, Ltd.

  4. Olefins and chemical regulation in Europe: REACH.

    PubMed

    Penman, Mike; Banton, Marcy; Erler, Steffen; Moore, Nigel; Semmler, Klaus

    2015-11-05

    REACH (Registration, Evaluation, Authorisation and Restriction of Chemicals) is the European Union's chemical regulation for the management of risk to human health and the environment (European Chemicals Agency, 2006). This regulation entered into force in June 2007 and required manufacturers and importers to register substances produced in annual quantities of 1000 tonnes or more by December 2010, with further deadlines for lower tonnages in 2013 and 2018. Depending on the type of registration, required information included the substance's identification, the hazards of the substance, the potential exposure arising from the manufacture or import, the identified uses of the substance, and the operational conditions and risk management measures applied or recommended to downstream users. Among the content developed to support this information were Derived No-Effect Levels or Derived Minimal Effect Levels (DNELs/DMELs) for human health hazard assessment, Predicted No Effect Concentrations (PNECs) for environmental hazard assessment, and exposure scenarios for exposure and risk assessment. Once registered, substances may undergo evaluation by the European Chemicals Agency (ECHA) or Member State authorities and be subject to requests for additional information or testing as well as additional risk reduction measures. To manage the REACH registration and related activities for the European olefins and aromatics industry, the Lower Olefins and Aromatics REACH Consortium was formed in 2008 with administrative and technical support provided by Penman Consulting. A total of 135 substances are managed by this group including 26 individual chemical registrations (e.g. benzene, 1,3-butadiene) and 13 categories consisting of 5-26 substances. This presentation will describe the content of selected registrations prepared for 2010 in addition to the significant post-2010 activities. Beyond REACH, content of the registrations may also be relevant to other European activities, for example consideration of worker DNELs/DMELs for occupational exposure level setting, discussion of this aspect will be presented for 1,3-butadiene. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  5. 31 CFR 353.7 - Authorized forms of registration.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... bond may be registered in the name of one individual. Example: John A. Jones 123-45-6789. (2... form of registration “A and B” is not authorized. Examples: John A. Jones 123-45-6789 or Ella S. Jones 987-65-4321. John A. Jones 123-45-6789 or (Miss, Ms. or Mrs.) Ella S. Jones. Ella S. Jones 987-65-4321...

  6. 31 CFR 360.6 - Authorized forms of registration.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Service annuitant, pursuant to 5 U.S.C. 8345(e). John F. Green or Mary B. Doe, Trustees of the Estate of... ownership form. A bond may be registered in the name of one individual. Example: Julie B. Jones, 123-45-6789... coowners. The form of registration “A and B” is not authorized. Examples: David R. Johnson 123-45-6789 or...

  7. Fractionated stereotactic radiotherapy: a method to evaluate geometric and dosimetric uncertainties using radiochromic films.

    PubMed

    Coscia, Gianluca; Vaccara, Elena; Corvisiero, Roberta; Cavazzani, Paolo; Ruggieri, Filippo Grillo; Taccini, Gianni

    2009-07-01

    In the authors' hospital, stereotactic radiotherapy treatments are performed with a Varian Clinac 600C equipped with a BrainLAB m3 micro-multileaf-collimator generally using the dynamic conformal arc technique. Patient immobilization during the treatment is achieved with a fixation mask supplied by BrainLAB, made with two reinforced thermoplastic sheets fitting the patient's head. With this work the authors propose a method to evaluate treatment geometric accuracy and, consequently, to determine the amount of the margin to keep in the CTV-PTV expansion during the treatment planning. The reproducibility of the isocenter position was tested by simulating a complete treatment on the anthropomorphic phantom Alderson Rando, inserting in between two phantom slices a high sensitivity Gafchromic EBT film, properly prepared and calibrated, and repeating several treatment sessions, each time removing the fixing mask and replacing the film inside the phantom. The comparison between the dose distributions measured on films and computed by TPS, after a precise image registration procedure performed by a commercial piece of software (FILMQA, 3cognition LLC (Division of ISP), Wayne, NJ), allowed the authors to measure the repositioning errors, obtaining about 0.5 mm in case of central spherical PTV and about 1.5 mm in case of peripheral irregular PTV. Moreover, an evaluation of the errors in the registration procedure was performed, giving negligible values with respect to the quantities to be measured. The above intrinsic two-dimensional estimate of treatment accuracy has to be increased for the error in the third dimension, but the 2 mm margin the authors generally use for the CTV-PTV expansion seems adequate anyway. Using the same EBT films, a dosimetric verification of the treatment planning system was done. Measured dose values are larger or smaller than the nominal ones depending on geometric irradiation conditions, but, in the authors' experimental conditions, always within 4%.

  8. 78 FR 33447 - Draft Applications for Sealed Source and Device Evaluation and Registration

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-06-04

    ... NUCLEAR REGULATORY COMMISSION [NRC-2013-0104] Draft Applications for Sealed Source and Device... for sealed source and device evaluation and registration. The NRC is requesting public comment on... for Sealed Source and Device Evaluation and Registration.'' The document has been updated from the...

  9. Evaluation of the use of registration stickers.

    DOT National Transportation Integrated Search

    2011-04-01

    This research evaluated the potential costs and benefits of doing away with license plate registration stickers as part : of the registration renewal process for Pennsylvania. The research consisted of a comprehensive literature review, a : survey of...

  10. Evaluation of dementia education programs for pre-registration healthcare students-A review of the literature.

    PubMed

    Alushi, Ledia; Hammond, John A; Wood, Julia H

    2015-09-01

    In an aging society, the number of people living with dementia is rapidly increasing. Health care students receive little input on dementia during their pre-registration education, hence there is a requirement to improve education to work with this client group. The review aimed to focus on education on working with people with dementia for pre-registration healthcare students. A comprehensive review of the literature. Online databases Medline, PsychInfo, CINAHL, Science Direct and PubMed were used. The studies were selected according to the following criteria: main focus on education and training on working with people with dementia in pre-registration healthcare programs. Reports that described a training program but did not include evaluation were excluded. For inclusion, studies had to be published in English between January 2007 and March 2014. Identified papers were screened and reviewed by the three authors. Nine studies met the inclusion criteria. Most studies were based in North America, predominantly in nursing and medical education. Educational interventions chiefly aimed to improve students' knowledge, comfort level and attitudes toward people with dementia. It was shown that theoretical input alone did not give students the necessary skills to work with people with dementia. Educational interventions were most effective when a practice based experience was preceded by theoretical preparation. Most of the findings were positive, demonstrating the potential to improve students' knowledge, attitude and comfort level, however methods and evaluation were not always sufficiently reported, making them difficult to use or replicate. This review highlights the need for studies with rigorous methods to determine evidence based best practice for all those working with people with dementia in order to provide effective care and improve their quality of life. Copyright © 2015 Elsevier Ltd. All rights reserved.

  11. Act on the Registration and Evaluation of Chemicals (K-REACH) and replacement, reduction or refinement best practices

    PubMed Central

    2016-01-01

    Objectives Korea’s Act on the Registration and Evaluation of Chemicals (K-REACH) was enacted for the protection of human health and the environment in 2015. Considering that about 2000 new substances are introduced annually across the globe, the extent of animal testing requirement could be overwhelming unless regulators and companies work proactively to institute and enforce global best practices to replace, reduce or refine animal use. In this review, the way to reduce the animal use for K-REACH is discussed. Methods Background of the enforcement of the K-REACH and its details was reviewed along with the papers and regulatory documents regarding the limitation of animal experiments and its alternatives in order to discuss the regulatory adoption of alternative tests. Results Depending on the tonnage of the chemical used, the data required ranges from acute and other short-term studies for a single exposure route to testing via multiple exposure routes and costly, longer-term studies such as a full two-generation reproducibility toxicity. The European Registration, Evaluation, Authorization and Restriction of Chemicals regulation provides for mandatory sharing of vertebrate test data to avoid unnecessary duplication of animal use and test costs, and obligation to revise data requirements and test guidelines “as soon as possible” after relevant, validated replacement, reduction or refinement (3R) methods become available. Furthermore, the Organization for Economic Cooperation and Development actively accepts alternative animal tests and 3R to chemical toxicity tests. Conclusions Alternative tests which are more ethical and efficient than animal experiments should be widely used to assess the toxicity of chemicals for K-REACH registration. The relevant regulatory agencies will have to make efforts to actively adopt and uptake new alternative tests and 3R to K-REACH. PMID:28118702

  12. [Procedure for the marketing authorization of an antibacterial agent].

    PubMed

    López Navas, Antonio; García-Escribano Ráez, Nuria; Flores Juberías, Ángela; Suárez Gea, María Luisa

    2014-10-01

    The marketing authorization of a new medicinal product is the first step before being placed on the market, and includes the full investigation programme. In order to ensure their quality, safety and efficacy, medicinal products are closely regulated from their initial phases of investigation to their use in clinical practice. For registration purposes, the results of all the clinical and preclinical studies, along with quality data and the description of the manufacturing process should be submitted. All information collected is presented for review by the competent authority. The European Medicines Agency regulates the registration of medicines in Europe, and national agencies in each EU member state are responsible for the assessment of the marketing authorisation application. To facilitate the development of clinical programmes, there is a common framework for the evaluation of an antibacterial, which includes guidelines and an addendum, detailing the specific requirements that must be carried out in clinical trials to assess the efficacy and safety for most of the infections. Copyright © 2014 Elsevier España, S.L.U. y Sociedad Española de Enfermedades Infecciosas y Microbiología Clínica. All rights reserved.

  13. 3D-SIFT-Flow for atlas-based CT liver image segmentation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Xu, Yan, E-mail: xuyan04@gmail.com; Xu, Chenchao, E-mail: chenchaoxu33@gmail.com; Kuang, Xiao, E-mail: kuangxiao.ace@gmail.com

    Purpose: In this paper, the authors proposed a new 3D registration algorithm, 3D-scale invariant feature transform (SIFT)-Flow, for multiatlas-based liver segmentation in computed tomography (CT) images. Methods: In the registration work, the authors developed a new registration method that takes advantage of dense correspondence using the informative and robust SIFT feature. The authors computed the dense SIFT features for the source image and the target image and designed an objective function to obtain the correspondence between these two images. Labeling of the source image was then mapped to the target image according to the former correspondence, resulting in accurate segmentation.more » In the fusion work, the 2D-based nonparametric label transfer method was extended to 3D for fusing the registered 3D atlases. Results: Compared with existing registration algorithms, 3D-SIFT-Flow has its particular advantage in matching anatomical structures (such as the liver) that observe large variation/deformation. The authors observed consistent improvement over widely adopted state-of-the-art registration methods such as ELASTIX, ANTS, and multiatlas fusion methods such as joint label fusion. Experimental results of liver segmentation on the MICCAI 2007 Grand Challenge are encouraging, e.g., Dice overlap ratio 96.27% ± 0.96% by our method compared with the previous state-of-the-art result of 94.90% ± 2.86%. Conclusions: Experimental results show that 3D-SIFT-Flow is robust for segmenting the liver from CT images, which has large tissue deformation and blurry boundary, and 3D label transfer is effective and efficient for improving the registration accuracy.« less

  14. SU-C-207B-06: Comparison of Registration Methods for Modeling Pathologic Response of Esophageal Cancer to Chemoradiation Therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Riyahi, S; Choi, W; Bhooshan, N

    2016-06-15

    Purpose: To compare linear and deformable registration methods for evaluation of tumor response to Chemoradiation therapy (CRT) in patients with esophageal cancer. Methods: Linear and multi-resolution BSpline deformable registration were performed on Pre-Post-CRT CT/PET images of 20 patients with esophageal cancer. For both registration methods, we registered CT using Mean Square Error (MSE) metric, however to register PET we used transformation obtained using Mutual Information (MI) from the same CT due to being multi-modality. Similarity of Warped-CT/PET was quantitatively evaluated using Normalized Mutual Information and plausibility of DF was assessed using inverse consistency Error. To evaluate tumor response four groupsmore » of tumor features were examined: (1) Conventional PET/CT e.g. SUV, diameter (2) Clinical parameters e.g. TNM stage, histology (3)spatial-temporal PET features that describe intensity, texture and geometry of tumor (4)all features combined. Dominant features were identified using 10-fold cross-validation and Support Vector Machine (SVM) was deployed for tumor response prediction while the accuracy was evaluated by ROC Area Under Curve (AUC). Results: Average and standard deviation of Normalized mutual information for deformable registration using MSE was 0.2±0.054 and for linear registration was 0.1±0.026, showing higher NMI for deformable registration. Likewise for MI metric, deformable registration had 0.13±0.035 comparing to linear counterpart with 0.12±0.037. Inverse consistency error for deformable registration for MSE metric was 4.65±2.49 and for linear was 1.32±2.3 showing smaller value for linear registration. The same conclusion was obtained for MI in terms of inverse consistency error. AUC for both linear and deformable registration was 1 showing no absolute difference in terms of response evaluation. Conclusion: Deformable registration showed better NMI comparing to linear registration, however inverse consistency of transformation was lower in linear registration. We do not expect to see significant difference when warping PET images using deformable or linear registration. This work was supported in part by the National Cancer Institute Grants R01CA172638.« less

  15. Estimating fatality rates in occupational light vehicle users using vehicle registration and crash data.

    PubMed

    Stuckey, Rwth; LaMontagne, Anthony D; Glass, Deborah C; Sim, Malcolm R

    2010-04-01

    To estimate occupational light vehicle (OLV) fatality numbers using vehicle registration and crash data and compare these with previous estimates based on workers' compensation data. New South Wales (NSW) Roads and Traffic Authority (RTA) vehicle registration and crash data were obtained for 2004. NSW is the only Australian jurisdiction with mandatory work-use registration, which was used as a proxy for work-relatedness. OLV fatality rates based on registration data as the denominator were calculated and comparisons made with published 2003/04 fatalities based on workers' compensation data. Thirty-four NSW RTA OLV-user fatalities were identified, a rate of 4.5 deaths per 100,000 organisationally registered OLV, whereas the Australian Safety and Compensation Council (ASCC), reported 28 OLV deaths Australia-wide. More OLV user fatalities were identified from vehicle registration-based data than those based on workers' compensation estimates and the data are likely to provide an improved estimate of fatalities specific to OLV use. OLV-use is an important cause of traumatic fatalities that would be better identified through the use of vehicle-registration data, which provides a stronger evidence base from which to develop policy responses. © 2010 The Authors. Journal Compilation © 2010 Public Health Association of Australia.

  16. Automated registration of multispectral MR vessel wall images of the carotid artery

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Klooster, R. van 't; Staring, M.; Reiber, J. H. C.

    2013-12-15

    Purpose: Atherosclerosis is the primary cause of heart disease and stroke. The detailed assessment of atherosclerosis of the carotid artery requires high resolution imaging of the vessel wall using multiple MR sequences with different contrast weightings. These images allow manual or automated classification of plaque components inside the vessel wall. Automated classification requires all sequences to be in alignment, which is hampered by patient motion. In clinical practice, correction of this motion is performed manually. Previous studies applied automated image registration to correct for motion using only nondeformable transformation models and did not perform a detailed quantitative validation. The purposemore » of this study is to develop an automated accurate 3D registration method, and to extensively validate this method on a large set of patient data. In addition, the authors quantified patient motion during scanning to investigate the need for correction. Methods: MR imaging studies (1.5T, dedicated carotid surface coil, Philips) from 55 TIA/stroke patients with ipsilateral <70% carotid artery stenosis were randomly selected from a larger cohort. Five MR pulse sequences were acquired around the carotid bifurcation, each containing nine transverse slices: T1-weighted turbo field echo, time of flight, T2-weighted turbo spin-echo, and pre- and postcontrast T1-weighted turbo spin-echo images (T1W TSE). The images were manually segmented by delineating the lumen contour in each vessel wall sequence and were manually aligned by applying throughplane and inplane translations to the images. To find the optimal automatic image registration method, different masks, choice of the fixed image, different types of the mutual information image similarity metric, and transformation models including 3D deformable transformation models, were evaluated. Evaluation of the automatic registration results was performed by comparing the lumen segmentations of the fixed image and moving image after registration. Results: The average required manual translation per image slice was 1.33 mm. Translations were larger as the patient was longer inside the scanner. Manual alignment took 187.5 s per patient resulting in a mean surface distance of 0.271 ± 0.127 mm. After minimal user interaction to generate the mask in the fixed image, the remaining sequences are automatically registered with a computation time of 52.0 s per patient. The optimal registration strategy used a circular mask with a diameter of 10 mm, a 3D B-spline transformation model with a control point spacing of 15 mm, mutual information as image similarity metric, and the precontrast T1W TSE as fixed image. A mean surface distance of 0.288 ± 0.128 mm was obtained with these settings, which is very close to the accuracy of the manual alignment procedure. The exact registration parameters and software were made publicly available. Conclusions: An automated registration method was developed and optimized, only needing two mouse clicks to mark the start and end point of the artery. Validation on a large group of patients showed that automated image registration has similar accuracy as the manual alignment procedure, substantially reducing the amount of user interactions needed, and is multiple times faster. In conclusion, the authors believe that the proposed automated method can replace the current manual procedure, thereby reducing the time to analyze the images.« less

  17. Concept of biosimilar products in Jordan.

    PubMed

    Haddadin, Rania Dakhlallah

    2011-09-01

    After the expiration of patents on originator biological products, Jordanian local manufacturers and the agents of international pharmaceutical companies in Jordan started to submit registration dossiers for biosimilar products. The Jordan Food and Drug Administration (JFDA) is the national regulatory authority responsible for the registration of biosimilar products. Biosimilars are registered under the same regulations used for drugs until specific guidelines for registration of biological and biosimilar products are released. Those regulations are called Criteria of Registration of Drugs, Vaccines, Sera and Biological Products, the Renewal of its Registration and the Cancellation of Any of them which was published in the official gazette in 2004 under the Provisional Law Number 80 of the year 2001, Drug and Pharmacy Law and its amendments of the year 2003. Also, the JFDA follows the EMA guidelines on similar biological medicinal products for specific active biological substances for non-clinical and clinical studies requirements and the EMA guideline on similar biological medicinal products containing biotechnology-derived proteins as active substance: quality issues. A post marketing surveillance study is requested after a biosimilar product is authorized. The JFDA keeps pace with all advances in the regulatory issues related to biosimilars in order to be capable of authorizing biosimilar products with a safe, effective and good quality profile. Copyright © 2011. Published by Elsevier Ltd.

  18. 77 FR 15234 - Controlled Substances and List I Chemical Registration and Reregistration Fees

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-03-15

    ...-tetrahydrocannabinol (THC), the active principle of marijuana) and synthetic cathinones (drugs of the phenethylamine... benefit from their authorization by registration to handle controlled substances. This commenter believed...

  19. Mammogram registration: a phantom-based evaluation of compressed breast thickness variation effects.

    PubMed

    Richard, Frédéric J P; Bakić, Predrag R; Maidment, Andrew D A

    2006-02-01

    The temporal comparison of mammograms is complex; a wide variety of factors can cause changes in image appearance. Mammogram registration is proposed as a method to reduce the effects of these changes and potentially to emphasize genuine alterations in breast tissue. Evaluation of such registration techniques is difficult since ground truth regarding breast deformations is not available in clinical mammograms. In this paper, we propose a systematic approach to evaluate sensitivity of registration methods to various types of changes in mammograms using synthetic breast images with known deformations. As a first step, images of the same simulated breasts with various amounts of simulated physical compression have been used to evaluate a previously described nonrigid mammogram registration technique. Registration performance is measured by calculating the average displacement error over a set of evaluation points identified in mammogram pairs. Applying appropriate thickness compensation and using a preferred order of the registered images, we obtained an average displacement error of 1.6 mm for mammograms with compression differences of 1-3 cm. The proposed methodology is applicable to analysis of other sources of mammogram differences and can be extended to the registration of multimodality breast data.

  20. Petition for Rulemaking to Evaluate Synergestic Effects of Pesticides during Registration and Registration Review

    EPA Pesticide Factsheets

    This petition from the Center for Biological Diversity asks that the Agency require all applicants and registrants to provide data on the potential synergistic effects of pesticides during the registration and registration review processes.

  1. Specific environmental release categories--A tool for improving chemical safety assessment in the EC--report of a multi-stakeholder workshop.

    PubMed

    Sättler, Daniel; Schnöder, Frank; Aust, Nannett; Ahrens, Andreas; Bögi, Christian; Traas, Theo; Tolls, Johannes

    2012-10-01

    In April 2011, experts from industry and authorities met for a workshop to discuss experience and future developments regarding the use of specific environmental release categories (SPERCs) in chemicals safety assessment (CSA) under the European Chemicals Regulation Registration, Evaluation and Authorization of Chemicals (REACH). This article provides a summary of the workshop. It briefly explains what a SPERC is, why SPERCs are needed, where the challenges of the concept are, and what improvements are needed to make SPERCs a useful tool for assessments under REACH. Copyright © 2012 SETAC.

  2. Serial Scanning and Registration of High Resolution Quantitative Computed Tomography Volume Scans for the Determination of Local Bone Density Changes

    NASA Technical Reports Server (NTRS)

    Whalen, Robert T.; Napel, Sandy; Yan, Chye H.

    1996-01-01

    Progress in development of the methods required to study bone remodeling as a function of time is reported. The following topics are presented: 'A New Methodology for Registration Accuracy Evaluation', 'Registration of Serial Skeletal Images for Accurately Measuring Changes in Bone Density', and 'Precise and Accurate Gold Standard for Multimodality and Serial Registration Method Evaluations.'

  3. Quantitative modeling of the accuracy in registering preoperative patient-specific anatomic models into left atrial cardiac ablation procedures

    PubMed Central

    Rettmann, Maryam E.; Holmes, David R.; Kwartowitz, David M.; Gunawan, Mia; Johnson, Susan B.; Camp, Jon J.; Cameron, Bruce M.; Dalegrave, Charles; Kolasa, Mark W.; Packer, Douglas L.; Robb, Richard A.

    2014-01-01

    Purpose: In cardiac ablation therapy, accurate anatomic guidance is necessary to create effective tissue lesions for elimination of left atrial fibrillation. While fluoroscopy, ultrasound, and electroanatomic maps are important guidance tools, they lack information regarding detailed patient anatomy which can be obtained from high resolution imaging techniques. For this reason, there has been significant effort in incorporating detailed, patient-specific models generated from preoperative imaging datasets into the procedure. Both clinical and animal studies have investigated registration and targeting accuracy when using preoperative models; however, the effect of various error sources on registration accuracy has not been quantitatively evaluated. Methods: Data from phantom, canine, and patient studies are used to model and evaluate registration accuracy. In the phantom studies, data are collected using a magnetically tracked catheter on a static phantom model. Monte Carlo simulation studies were run to evaluate both baseline errors as well as the effect of different sources of error that would be present in a dynamic in vivo setting. Error is simulated by varying the variance parameters on the landmark fiducial, physical target, and surface point locations in the phantom simulation studies. In vivo validation studies were undertaken in six canines in which metal clips were placed in the left atrium to serve as ground truth points. A small clinical evaluation was completed in three patients. Landmark-based and combined landmark and surface-based registration algorithms were evaluated in all studies. In the phantom and canine studies, both target registration error and point-to-surface error are used to assess accuracy. In the patient studies, no ground truth is available and registration accuracy is quantified using point-to-surface error only. Results: The phantom simulation studies demonstrated that combined landmark and surface-based registration improved landmark-only registration provided the noise in the surface points is not excessively high. Increased variability on the landmark fiducials resulted in increased registration errors; however, refinement of the initial landmark registration by the surface-based algorithm can compensate for small initial misalignments. The surface-based registration algorithm is quite robust to noise on the surface points and continues to improve landmark registration even at high levels of noise on the surface points. Both the canine and patient studies also demonstrate that combined landmark and surface registration has lower errors than landmark registration alone. Conclusions: In this work, we describe a model for evaluating the impact of noise variability on the input parameters of a registration algorithm in the context of cardiac ablation therapy. The model can be used to predict both registration error as well as assess which inputs have the largest effect on registration accuracy. PMID:24506630

  4. Quantitative modeling of the accuracy in registering preoperative patient-specific anatomic models into left atrial cardiac ablation procedures

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rettmann, Maryam E., E-mail: rettmann.maryam@mayo.edu; Holmes, David R.; Camp, Jon J.

    2014-02-15

    Purpose: In cardiac ablation therapy, accurate anatomic guidance is necessary to create effective tissue lesions for elimination of left atrial fibrillation. While fluoroscopy, ultrasound, and electroanatomic maps are important guidance tools, they lack information regarding detailed patient anatomy which can be obtained from high resolution imaging techniques. For this reason, there has been significant effort in incorporating detailed, patient-specific models generated from preoperative imaging datasets into the procedure. Both clinical and animal studies have investigated registration and targeting accuracy when using preoperative models; however, the effect of various error sources on registration accuracy has not been quantitatively evaluated. Methods: Datamore » from phantom, canine, and patient studies are used to model and evaluate registration accuracy. In the phantom studies, data are collected using a magnetically tracked catheter on a static phantom model. Monte Carlo simulation studies were run to evaluate both baseline errors as well as the effect of different sources of error that would be present in a dynamicin vivo setting. Error is simulated by varying the variance parameters on the landmark fiducial, physical target, and surface point locations in the phantom simulation studies. In vivo validation studies were undertaken in six canines in which metal clips were placed in the left atrium to serve as ground truth points. A small clinical evaluation was completed in three patients. Landmark-based and combined landmark and surface-based registration algorithms were evaluated in all studies. In the phantom and canine studies, both target registration error and point-to-surface error are used to assess accuracy. In the patient studies, no ground truth is available and registration accuracy is quantified using point-to-surface error only. Results: The phantom simulation studies demonstrated that combined landmark and surface-based registration improved landmark-only registration provided the noise in the surface points is not excessively high. Increased variability on the landmark fiducials resulted in increased registration errors; however, refinement of the initial landmark registration by the surface-based algorithm can compensate for small initial misalignments. The surface-based registration algorithm is quite robust to noise on the surface points and continues to improve landmark registration even at high levels of noise on the surface points. Both the canine and patient studies also demonstrate that combined landmark and surface registration has lower errors than landmark registration alone. Conclusions: In this work, we describe a model for evaluating the impact of noise variability on the input parameters of a registration algorithm in the context of cardiac ablation therapy. The model can be used to predict both registration error as well as assess which inputs have the largest effect on registration accuracy.« less

  5. Evaluation of mathematical algorithms for automatic patient alignment in radiosurgery.

    PubMed

    Williams, Kenneth M; Schulte, Reinhard W; Schubert, Keith E; Wroe, Andrew J

    2015-06-01

    Image registration techniques based on anatomical features can serve to automate patient alignment for intracranial radiosurgery procedures in an effort to improve the accuracy and efficiency of the alignment process as well as potentially eliminate the need for implanted fiducial markers. To explore this option, four two-dimensional (2D) image registration algorithms were analyzed: the phase correlation technique, mutual information (MI) maximization, enhanced correlation coefficient (ECC) maximization, and the iterative closest point (ICP) algorithm. Digitally reconstructed radiographs from the treatment planning computed tomography scan of a human skull were used as the reference images, while orthogonal digital x-ray images taken in the treatment room were used as the captured images to be aligned. The accuracy of aligning the skull with each algorithm was compared to the alignment of the currently practiced procedure, which is based on a manual process of selecting common landmarks, including implanted fiducials and anatomical skull features. Of the four algorithms, three (phase correlation, MI maximization, and ECC maximization) demonstrated clinically adequate (ie, comparable to the standard alignment technique) translational accuracy and improvements in speed compared to the interactive, user-guided technique; however, the ICP algorithm failed to give clinically acceptable results. The results of this work suggest that a combination of different algorithms may provide the best registration results. This research serves as the initial groundwork for the translation of automated, anatomy-based 2D algorithms into a real-world system for 2D-to-2D image registration and alignment for intracranial radiosurgery. This may obviate the need for invasive implantation of fiducial markers into the skull and may improve treatment room efficiency and accuracy. © The Author(s) 2014.

  6. Accuracy of surface registration compared to conventional volumetric registration in patient positioning for head-and-neck radiotherapy: A simulation study using patient data

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kim, Youngjun; Li, Ruijiang; Na, Yong Hum

    2014-12-15

    Purpose: 3D optical surface imaging has been applied to patient positioning in radiation therapy (RT). The optical patient positioning system is advantageous over conventional method using cone-beam computed tomography (CBCT) in that it is radiation free, frameless, and is capable of real-time monitoring. While the conventional radiographic method uses volumetric registration, the optical system uses surface matching for patient alignment. The relative accuracy of these two methods has not yet been sufficiently investigated. This study aims to investigate the theoretical accuracy of the surface registration based on a simulation study using patient data. Methods: This study compares the relative accuracymore » of surface and volumetric registration in head-and-neck RT. The authors examined 26 patient data sets, each consisting of planning CT data acquired before treatment and patient setup CBCT data acquired at the time of treatment. As input data of surface registration, patient’s skin surfaces were created by contouring patient skin from planning CT and treatment CBCT. Surface registration was performed using the iterative closest points algorithm by point–plane closest, which minimizes the normal distance between source points and target surfaces. Six degrees of freedom (three translations and three rotations) were used in both surface and volumetric registrations and the results were compared. The accuracy of each method was estimated by digital phantom tests. Results: Based on the results of 26 patients, the authors found that the average and maximum root-mean-square translation deviation between the surface and volumetric registrations were 2.7 and 5.2 mm, respectively. The residual error of the surface registration was calculated to have an average of 0.9 mm and a maximum of 1.7 mm. Conclusions: Surface registration may lead to results different from those of the conventional volumetric registration. Only limited accuracy can be achieved for patient positioning with an approach based solely on surface information.« less

  7. Endorsement of the CONSORT guidelines, trial registration, and the quality of reporting randomised controlled trials in leading nursing journals: A cross-sectional analysis.

    PubMed

    Jull, Andrew; Aye, Phyu Sin

    2015-06-01

    To establish the reporting quality of trials published in leading nursing journals and investigate associations between CONSORT Statement or trial registration endorsment and reporting of design elements. The top 15 nursing journals were searched using Medline for randomised controlled trials published in 2012. Journals were categorised as CONSORT and trial registration promoting based on requirements of submitting authors or the journal's webpage as at January 2014. Data on sequence generation, allocation concealment, follow up, blinding, baseline equivalence and sample size calculation were extracted by one author and independently verified by the second author against source data. Seven journals were CONSORT promoting and three of these journals were also trial registration promoting. 114 citations were identified and 83 were randomised controlled trials. Eighteen trials (21.7%) were registered and those published in trial registration promoting journals were more likely to be registered (RR 2.64 95%CI 1.14-6.09). We assessed 68.7% of trials to be low risk of bias for sequence generation, 20.5% for allocation concealment, 38.6% for blinding, 55.4% for completeness of follow up and 79.5% for baseline equivalence. Trials published in CONSORT promoting journals were more likely to be at low risk of bias for blinding (RR 2.33, 95%CI 1.01-5.34) and completeness of follow up (RR 1.77, 95%CI 1.02-3.10), but journal endorsement of the CONSORT Statement or trial registration otherwise had no significant effect. Trials published in CONSORT and trial registration promoting journals were more likely to have high quality sample size calculations (RR 2.91, 95%CI 1.18-7.19 and RR 1.69, 95%CI 1.08-2.64, respectively). Simple endorsement of the CONSORT Statement and trials registration is insufficient action to encourage improvement of the quality of trial reporting across the most important of trial design elements. Copyright © 2014 Elsevier Ltd. All rights reserved.

  8. EMEA and Gene Therapy Medicinal Products Development in the European Union

    PubMed Central

    2003-01-01

    The evaluation of quality, safety, and efficacy of medicinal products by the European Medicines Evaluation Agency (EMEA) via the centralized procedure is the only available regulatory procedure for obtaining marketing authorization for gene therapy (GT) medicinal products in the European Union. The responsibility for the authorization of clinical trials remains with the national competent authorities (NCA) acting in a harmonized framework from the scientific viewpoint. With the entry into force of a new directive on good clinical practice implementation in clinical trials as of 1 May 2004, procedural aspects will also be harmonized at EU level. Scientifically sound development of medicinal products is the key for the successful registration of dossiers and for contributing to the promotion and protection of public health. The objective of this paper is to introduce the EMEA regulatory processes and scientific activities relevant to GT medicinal products. PMID:12686717

  9. Intrasubject multimodal groupwise registration with the conditional template entropy.

    PubMed

    Polfliet, Mathias; Klein, Stefan; Huizinga, Wyke; Paulides, Margarethus M; Niessen, Wiro J; Vandemeulebroucke, Jef

    2018-05-01

    Image registration is an important task in medical image analysis. Whereas most methods are designed for the registration of two images (pairwise registration), there is an increasing interest in simultaneously aligning more than two images using groupwise registration. Multimodal registration in a groupwise setting remains difficult, due to the lack of generally applicable similarity metrics. In this work, a novel similarity metric for such groupwise registration problems is proposed. The metric calculates the sum of the conditional entropy between each image in the group and a representative template image constructed iteratively using principal component analysis. The proposed metric is validated in extensive experiments on synthetic and intrasubject clinical image data. These experiments showed equivalent or improved registration accuracy compared to other state-of-the-art (dis)similarity metrics and improved transformation consistency compared to pairwise mutual information. Copyright © 2018 The Authors. Published by Elsevier B.V. All rights reserved.

  10. Sex Offender Registration: Balancing the Rights of the Individual with the Public Good--A Commentary on Comartin, Kernsmith, and Miles (2010)

    ERIC Educational Resources Information Center

    Berkowitz, Carol D.

    2010-01-01

    This article presents the author's comments on the article "Family Experiences of Young Adult Sex Offender Registration" by E. B. Comartin, P. D. Kernsmith, & P. W. Miles (2010). In the article "Family Experiences of Young Adult Sex Offender Registration", Comartin, Kernsmith, and Miles (2010) put forth a telling argument about the impact of the…

  11. Development and evaluation of an articulated registration algorithm for human skeleton registration

    NASA Astrophysics Data System (ADS)

    Yip, Stephen; Perk, Timothy; Jeraj, Robert

    2014-03-01

    Accurate registration over multiple scans is necessary to assess treatment response of bone diseases (e.g. metastatic bone lesions). This study aimed to develop and evaluate an articulated registration algorithm for the whole-body skeleton registration in human patients. In articulated registration, whole-body skeletons are registered by auto-segmenting into individual bones using atlas-based segmentation, and then rigidly aligning them. Sixteen patients (weight = 80-117 kg, height = 168-191 cm) with advanced prostate cancer underwent the pre- and mid-treatment PET/CT scans over a course of cancer therapy. Skeletons were extracted from the CT images by thresholding (HU>150). Skeletons were registered using the articulated, rigid, and deformable registration algorithms to account for position and postural variability between scans. The inter-observers agreement in the atlas creation, the agreement between the manually and atlas-based segmented bones, and the registration performances of all three registration algorithms were all assessed using the Dice similarity index—DSIobserved, DSIatlas, and DSIregister. Hausdorff distance (dHausdorff) of the registered skeletons was also used for registration evaluation. Nearly negligible inter-observers variability was found in the bone atlases creation as the DSIobserver was 96 ± 2%. Atlas-based and manual segmented bones were in excellent agreement with DSIatlas of 90 ± 3%. Articulated (DSIregsiter = 75 ± 2%, dHausdorff = 0.37 ± 0.08 cm) and deformable registration algorithms (DSIregister = 77 ± 3%, dHausdorff = 0.34 ± 0.08 cm) considerably outperformed the rigid registration algorithm (DSIregsiter = 59 ± 9%, dHausdorff = 0.69 ± 0.20 cm) in the skeleton registration as the rigid registration algorithm failed to capture the skeleton flexibility in the joints. Despite superior skeleton registration performance, deformable registration algorithm failed to preserve the local rigidity of bones as over 60% of the skeletons were deformed. Articulated registration is superior to rigid and deformable registrations by capturing global flexibility while preserving local rigidity inherent in skeleton registration. Therefore, articulated registration can be employed to accurately register the whole-body human skeletons, and it enables the treatment response assessment of various bone diseases.

  12. [Differences between clinical trials according to the German law on pharmaceuticals (Arzneimittelgesetz) and trials according to the German law on medical products (Medizinproduktegesetz)].

    PubMed

    Krummenauer, F

    2003-02-01

    Similar to the registration process for pharmaceutical agents, medical devices have to undergo standardized clinical evaluation before being marketed and used in routine therapy or diagnostics. However, conduction, submission, and reporting of such clinical evaluations to authorities has to follow the German law on medical products(Medizinproduktegesetz,MPG), which in some central aspects differs remarkably from the German law on pharmaceuticals (Arzneimittelgesetz,AMG). Relevant deviations of MPG requirements from those of the AMG are reviewed with particular emphasis on submission, conduction, and reporting of trials to the authorities in charge. Whereas AMG-based trials focus on the proof of efficacy of pharmaceutical agents, the MPG demands instead proof of functionality of the medical devices; the MPG therefore concentrates more on technically satisfactory results in the context of function and patient safety. The aim of MPG trials is thus CE marking instead of AMG-based registration. However, this focus on functionality implies that medical devices need not necessarily be tested in a clinical trial--in some settings evidence-based evaluation alone will be sufficient. The decision on the necessity of a clinical trial is based mainly on the risk profile and invasive character of the device at hand. The early consideration of differences between AMG and MPG concerning the role and conduction of clinical trials will remarkably increase the (CE) certification process's outcome quality and juridical validity.

  13. Evaluation of 4D-CT lung registration.

    PubMed

    Kabus, Sven; Klinder, Tobias; Murphy, Keelin; van Ginneken, Bram; van Lorenz, Cristian; Pluim, Josien P W

    2009-01-01

    Non-rigid registration accuracy assessment is typically performed by evaluating the target registration error at manually placed landmarks. For 4D-CT lung data, we compare two sets of landmark distributions: a smaller set primarily defined on vessel bifurcations as commonly described in the literature and a larger set being well-distributed throughout the lung volume. For six different registration schemes (three in-house schemes and three schemes frequently used by the community) the landmark error is evaluated and found to depend significantly on the distribution of the landmarks. In particular, lung regions near to the pleura show a target registration error three times larger than near-mediastinal regions. While the inter-method variability on the landmark positions is rather small, the methods show discriminating differences with respect to consistency and local volume change. In conclusion, both a well-distributed set of landmarks and a deformation vector field analysis are necessary for reliable non-rigid registration accuracy assessment.

  14. Modeling respiratory motion for reducing motion artifacts in 4D CT images.

    PubMed

    Zhang, Yongbin; Yang, Jinzhong; Zhang, Lifei; Court, Laurence E; Balter, Peter A; Dong, Lei

    2013-04-01

    Four-dimensional computed tomography (4D CT) images have been recently adopted in radiation treatment planning for thoracic and abdominal cancers to explicitly define respiratory motion and anatomy deformation. However, significant image distortions (artifacts) exist in 4D CT images that may affect accurate tumor delineation and the shape representation of normal anatomy. In this study, the authors present a patient-specific respiratory motion model, based on principal component analysis (PCA) of motion vectors obtained from deformable image registration, with the main goal of reducing image artifacts caused by irregular motion during 4D CT acquisition. For a 4D CT image set of a specific patient, the authors calculated displacement vector fields relative to a reference phase, using an in-house deformable image registration method. The authors then used PCA to decompose each of the displacement vector fields into linear combinations of principal motion bases. The authors have demonstrated that the regular respiratory motion of a patient can be accurately represented by a subspace spanned by three principal motion bases and their projections. These projections were parameterized using a spline model to allow the reconstruction of the displacement vector fields at any given phase in a respiratory cycle. Finally, the displacement vector fields were used to deform the reference CT image to synthesize CT images at the selected phase with much reduced image artifacts. The authors evaluated the performance of the in-house deformable image registration method using benchmark datasets consisting of ten 4D CT sets annotated with 300 landmark pairs that were approved by physicians. The initial large discrepancies across the landmark pairs were significantly reduced after deformable registration, and the accuracy was similar to or better than that reported by state-of-the-art methods. The proposed motion model was quantitatively validated on 4D CT images of a phantom and a lung cancer patient by comparing the synthesized images and the original images at different phases. The synthesized images matched well with the original images. The motion model was used to reduce irregular motion artifacts in the 4D CT images of three lung cancer patients. Visual assessment indicated that the proposed approach could reduce severe image artifacts. The shape distortions around the diaphragm and tumor regions were mitigated in the synthesized 4D CT images. The authors have derived a mathematical model to represent the regular respiratory motion from a patient-specific 4D CT set and have demonstrated its application in reducing irregular motion artifacts in 4D CT images. The authors' approach can mitigate shape distortions of anatomy caused by irregular breathing motion during 4D CT acquisition.

  15. Validation of an algorithm for the nonrigid registration of longitudinal breast MR images using realistic phantoms

    PubMed Central

    Li, Xia; Dawant, Benoit M.; Welch, E. Brian; Chakravarthy, A. Bapsi; Xu, Lei; Mayer, Ingrid; Kelley, Mark; Meszoely, Ingrid; Means-Powell, Julie; Gore, John C.; Yankeelov, Thomas E.

    2010-01-01

    Purpose: The authors present a method to validate coregistration of breast magnetic resonance images obtained at multiple time points during the course of treatment. In performing sequential registration of breast images, the effects of patient repositioning, as well as possible changes in tumor shape and volume, must be considered. The authors accomplish this by extending the adaptive bases algorithm (ABA) to include a tumor-volume preserving constraint in the cost function. In this study, the authors evaluate this approach using a novel validation method that simulates not only the bulk deformation associated with breast MR images obtained at different time points, but also the reduction in tumor volume typically observed as a response to neoadjuvant chemotherapy. Methods: For each of the six patients, high-resolution 3D contrast enhanced T1-weighted images were obtained before treatment, after one cycle of chemotherapy and at the conclusion of chemotherapy. To evaluate the effects of decreasing tumor size during the course of therapy, simulations were run in which the tumor in the original images was contracted by 25%, 50%, 75%, and 95%, respectively. The contracted area was then filled using texture from local healthy appearing tissue. Next, to simulate the post-treatment data, the simulated (i.e., contracted tumor) images were coregistered to the experimentally measured post-treatment images using a surface registration. By comparing the deformations generated by the constrained and unconstrained version of ABA, the authors assessed the accuracy of the registration algorithms. The authors also applied the two algorithms on experimental data to study the tumor volume changes, the value of the constraint, and the smoothness of transformations. Results: For the six patient data sets, the average voxel shift error (mean±standard deviation) for the ABA with constraint was 0.45±0.37, 0.97±0.83, 1.43±0.96, and 1.80±1.17 mm for the 25%, 50%, 75%, and 95% contraction simulations, respectively. In comparison, the average voxel shift error for the unconstrained ABA was 0.46±0.29, 1.13±1.17, 2.40±2.04, and 3.53±2.89 mm, respectively. These voxel shift errors translate into compression of the tumor volume: The ABA with constraint returned volumetric errors of 2.70±4.08%, 7.31±4.52%, 9.28±5.55%, and 13.19±6.73% for the 25%, 50%, 75%, and 95% contraction simulations, respectively, whereas the unconstrained ABA returned volumetric errors of 4.00±4.46%, 9.93±4.83%, 19.78±5.657%, and 29.75±15.18%. The ABA with constraint yields a smaller mean shift error, as well as a smaller volume error (p=0.031 25 for the 75% and 95% contractions), than the unconstrained ABA for the simulated sets. Visual and quantitative assessments on experimental data also indicate a good performance of the proposed algorithm. Conclusions: The ABA with constraint can successfully register breast MR images acquired at different time points with reasonable error. To the best of the authors’ knowledge, this is the first report of an attempt to quantitatively assess in both phantoms and a set of patients the accuracy of a registration algorithm for this purpose. PMID:20632566

  16. The Importance of Soil Protein Fate to PIP Crop Registration

    EPA Science Inventory

    Plant Incorporated Protectant (PIP) crops are registered under the authority of the Federal Insecticide Fungicide and Rodenticide Act (FIFRA) and as part of this registration certain environmental fate information is required to properly judge the environmental compatibility of n...

  17. Guidance on FIFRA 24(c) Registrations

    EPA Pesticide Factsheets

    Under the authority of §24(c) of FIFRA, states may register an additional use of a federally registered pesticide product, or a new end use product to meet special local needs. Learn about the process and how EPA reviews these registrations.

  18. Spatially weighted mutual information image registration for image guided radiation therapy.

    PubMed

    Park, Samuel B; Rhee, Frank C; Monroe, James I; Sohn, Jason W

    2010-09-01

    To develop a new metric for image registration that incorporates the (sub)pixelwise differential importance along spatial location and to demonstrate its application for image guided radiation therapy (IGRT). It is well known that rigid-body image registration with mutual information is dependent on the size and location of the image subset on which the alignment analysis is based [the designated region of interest (ROI)]. Therefore, careful review and manual adjustments of the resulting registration are frequently necessary. Although there were some investigations of weighted mutual information (WMI), these efforts could not apply the differential importance to a particular spatial location since WMI only applies the weight to the joint histogram space. The authors developed the spatially weighted mutual information (SWMI) metric by incorporating an adaptable weight function with spatial localization into mutual information. SWMI enables the user to apply the selected transform to medically "important" areas such as tumors and critical structures, so SWMI is neither dominated by, nor neglects the neighboring structures. Since SWMI can be utilized with any weight function form, the authors presented two examples of weight functions for IGRT application: A Gaussian-shaped weight function (GW) applied to a user-defined location and a structures-of-interest (SOI) based weight function. An image registration example using a synthesized 2D image is presented to illustrate the efficacy of SWMI. The convergence and feasibility of the registration method as applied to clinical imaging is illustrated by fusing a prostate treatment planning CT with a clinical cone beam CT (CBCT) image set acquired for patient alignment. Forty-one trials are run to test the speed of convergence. The authors also applied SWMI registration using two types of weight functions to two head and neck cases and a prostate case with clinically acquired CBCT/ MVCT image sets. The SWMI registration with a Gaussian weight function (SWMI-GW) was tested between two different imaging modalities: CT and MRI image sets. SWMI-GW converges 10% faster than registration using mutual information with an ROI. SWMI-GW as well as SWMI with SOI-based weight function (SWMI-SOI) shows better compensation of the target organ's deformation and neighboring critical organs' deformation. SWMI-GW was also used to successfully fuse MRI and CT images. Rigid-body image registration using our SWMI-GW and SWMI-SOI as cost functions can achieve better registration results in (a) designated image region(s) as well as faster convergence. With the theoretical foundation established, we believe SWMI could be extended to larger clinical testing.

  19. Comparative Evaluation of Registration Algorithms in Different Brain Databases With Varying Difficulty: Results and Insights

    PubMed Central

    Akbari, Hamed; Bilello, Michel; Da, Xiao; Davatzikos, Christos

    2015-01-01

    Evaluating various algorithms for the inter-subject registration of brain magnetic resonance images (MRI) is a necessary topic receiving growing attention. Existing studies evaluated image registration algorithms in specific tasks or using specific databases (e.g., only for skull-stripped images, only for single-site images, etc.). Consequently, the choice of registration algorithms seems task- and usage/parameter-dependent. Nevertheless, recent large-scale, often multi-institutional imaging-related studies create the need and raise the question whether some registration algorithms can 1) generally apply to various tasks/databases posing various challenges; 2) perform consistently well, and while doing so, 3) require minimal or ideally no parameter tuning. In seeking answers to this question, we evaluated 12 general-purpose registration algorithms, for their generality, accuracy and robustness. We fixed their parameters at values suggested by algorithm developers as reported in the literature. We tested them in 7 databases/tasks, which present one or more of 4 commonly-encountered challenges: 1) inter-subject anatomical variability in skull-stripped images; 2) intensity homogeneity, noise and large structural differences in raw images; 3) imaging protocol and field-of-view (FOV) differences in multi-site data; and 4) missing correspondences in pathology-bearing images. Totally 7,562 registrations were performed. Registration accuracies were measured by (multi-)expert-annotated landmarks or regions of interest (ROIs). To ensure reproducibility, we used public software tools, public databases (whenever possible), and we fully disclose the parameter settings. We show evaluation results, and discuss the performances in light of algorithms’ similarity metrics, transformation models and optimization strategies. We also discuss future directions for the algorithm development and evaluations. PMID:24951685

  20. Acceptance test of a commercially available software for automatic image registration of computed tomography (CT), magnetic resonance imaging (MRI) and 99mTc-methoxyisobutylisonitrile (MIBI) single-photon emission computed tomography (SPECT) brain images.

    PubMed

    Loi, Gianfranco; Dominietto, Marco; Manfredda, Irene; Mones, Eleonora; Carriero, Alessandro; Inglese, Eugenio; Krengli, Marco; Brambilla, Marco

    2008-09-01

    This note describes a method to characterize the performances of image fusion software (Syntegra) with respect to accuracy and robustness. Computed tomography (CT), magnetic resonance imaging (MRI), and single-photon emission computed tomography (SPECT) studies were acquired from two phantoms and 10 patients. Image registration was performed independently by two couples composed of one radiotherapist and one physicist by means of superposition of anatomic landmarks. Each couple performed jointly and saved the registration. The two solutions were averaged to obtain the gold standard registration. A new set of estimators was defined to identify translation and rotation errors in the coordinate axes, independently from point position in image field of view (FOV). Algorithms evaluated were local correlation (LC) for CT-MRI, normalized mutual information (MI) for CT-MRI, and CT-SPECT registrations. To evaluate accuracy, estimator values were compared to limiting values for the algorithms employed, both in phantoms and in patients. To evaluate robustness, different alignments between images taken from a sample patient were produced and registration errors determined. LC algorithm resulted accurate in CT-MRI registrations in phantoms, but exceeded limiting values in 3 of 10 patients. MI algorithm resulted accurate in CT-MRI and CT-SPECT registrations in phantoms; limiting values were exceeded in one case in CT-MRI and never reached in CT-SPECT registrations. Thus, the evaluation of robustness was restricted to the algorithm of MI both for CT-MRI and CT-SPECT registrations. The algorithm of MI proved to be robust: limiting values were not exceeded with translation perturbations up to 2.5 cm, rotation perturbations up to 10 degrees and roto-translational perturbation up to 3 cm and 5 degrees.

  1. Realistic simulated MRI and SPECT databases. Application to SPECT/MRI registration evaluation.

    PubMed

    Aubert-Broche, Berengere; Grova, Christophe; Reilhac, Anthonin; Evans, Alan C; Collins, D Louis

    2006-01-01

    This paper describes the construction of simulated SPECT and MRI databases that account for realistic anatomical and functional variability. The data is used as a gold-standard to evaluate four SPECT/MRI similarity-based registration methods. Simulation realism was accounted for using accurate physical models of data generation and acquisition. MRI and SPECT simulations were generated from three subjects to take into account inter-subject anatomical variability. Functional SPECT data were computed from six functional models of brain perfusion. Previous models of normal perfusion and ictal perfusion observed in Mesial Temporal Lobe Epilepsy (MTLE) were considered to generate functional variability. We studied the impact noise and intensity non-uniformity in MRI simulations and SPECT scatter correction may have on registration accuracy. We quantified the amount of registration error caused by anatomical and functional variability. Registration involving ictal data was less accurate than registration involving normal data. MR intensity nonuniformity was the main factor decreasing registration accuracy. The proposed simulated database is promising to evaluate many functional neuroimaging methods, involving MRI and SPECT data.

  2. Image Registration for Stability Testing of MEMS

    NASA Technical Reports Server (NTRS)

    Memarsadeghi, Nargess; LeMoigne, Jacqueline; Blake, Peter N.; Morey, Peter A.; Landsman, Wayne B.; Chambers, Victor J.; Moseley, Samuel H.

    2011-01-01

    Image registration, or alignment of two or more images covering the same scenes or objects, is of great interest in many disciplines such as remote sensing, medical imaging. astronomy, and computer vision. In this paper, we introduce a new application of image registration algorithms. We demonstrate how through a wavelet based image registration algorithm, engineers can evaluate stability of Micro-Electro-Mechanical Systems (MEMS). In particular, we applied image registration algorithms to assess alignment stability of the MicroShutters Subsystem (MSS) of the Near Infrared Spectrograph (NIRSpec) instrument of the James Webb Space Telescope (JWST). This work introduces a new methodology for evaluating stability of MEMS devices to engineers as well as a new application of image registration algorithms to computer scientists.

  3. TU-AB-202-07: A Novel Method for Registration of Mid-Treatment PET/CT Images Under Conditions of Tumor Regression for Patients with Locally Advanced Lung Cancers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sharifi, Hoda; Department of Physics, Oakland University, Rochester, MI; Zhang, Hong

    Purpose: In PET-guided adaptive radiotherapy (RT), changes in the metabolic activity at individual voxels cannot be derived until the duringtreatment CT images are appropriately registered to pre-treatment CT images. However, deformable image registration (DIR) usually does not preserve tumor volume. This may induce errors when comparing to the target. The aim of this study was to develop a DIR-integrated mechanical modeling technique to track radiation-induced metabolic changes on PET images. Methods: Three patients with non-small cell lung cancer (NSCLC) were treated with adaptive radiotherapy under RTOG 1106. Two PET/CT image sets were acquired 2 weeks before RT and 18 fractionsmore » after the start of treatment. DIR was performed to register the during-RT CT to the pre-RT CT using a B-spline algorithm and the resultant displacements in the region of tumor were remodeled using a hybrid finite element method (FEM). Gross tumor volume (GTV) was delineated on the during-RT PET/CT image sets and deformed using the 3D deformation vector fields generated by the CT-based registrations. Metabolic tumor volume (MTV) was calculated using the pre- and during–RT image set. The quality of the PET mapping was evaluated based on the constancy of the mapped MTV and landmark comparison. Results: The B-spline-based registrations changed MTVs by 7.3%, 4.6% and −5.9% for the 3 patients and the correspondent changes for the hybrid FEM method −2.9%, 1% and 6.3%, respectively. Landmark comparisons were used to evaluate the Rigid, B-Spline, and hybrid FEM registrations with the mean errors of 10.1 ± 1.6 mm, 4.4 ± 0.4 mm, and 3.6 ± 0.4 mm for three patients. The hybrid FEM method outperforms the B-Spline-only registration for patients with tumor regression Conclusion: The hybrid FEM modeling technique improves the B-Spline registrations in tumor regions. This technique may help compare metabolic activities between two PET/CT images with regressing tumors. The author gratefully acknowledges the financial support from the National Institutes of Health Grant.« less

  4. 29 CFR 29.13 - Recognition of State Apprenticeship Agencies.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... its authority to grant recognition to a State Apprenticeship Agency. Recognition confers non-exclusive... carry out the functions of a Registration Agency, including: Outreach and education; registration of... the areas of non-conformity, require corrective action, and offer technical assistance. After the...

  5. Dual-projection 3D-2D registration for surgical guidance: preclinical evaluation of performance and minimum angular separation

    NASA Astrophysics Data System (ADS)

    Uneri, A.; Otake, Y.; Wang, A. S.; Kleinszig, G.; Vogt, S.; Gallia, G. L.; Rigamonti, D.; Wolinsky, J.-P.; Gokaslan, Ziya L.; Khanna, A. J.; Siewerdsen, J. H.

    2014-03-01

    An algorithm for 3D-2D registration of CT and x-ray projections has been developed using dual projection views to provide 3D localization with accuracy exceeding that of conventional tracking systems. The registration framework employs a normalized gradient information (NGI) similarity metric and covariance matrix adaptation evolution strategy (CMAES) to solve for the patient pose in 6 degrees of freedom. Registration performance was evaluated in anthropomorphic head and chest phantoms, as well as a human torso cadaver, using C-arm projection views acquired at angular separations (Δ𝜃) ranging 0-178°. Registration accuracy was assessed in terms target registration error (TRE) and compared to that of an electromagnetic tracker. Studies evaluated the influence of C-arm magnification, x-ray dose, and preoperative CT slice thickness on registration accuracy and the minimum angular separation required to achieve TRE ~2 mm. The results indicate that Δ𝜃 as small as 10-20° is adequate to achieve TRE <2 mm with 95% confidence, comparable or superior to that of commercial trackers. The method allows direct registration of preoperative CT and planning data to intraoperative fluoroscopy, providing 3D localization free from conventional limitations associated with external fiducial markers, stereotactic frames, trackers, and manual registration. The studies support potential application to percutaneous spine procedures and intracranial neurosurgery.

  6. 78 FR 12322 - Agency Information Collection Activities: OMB Review; Comment Request

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-02-22

    ... Interchange (EDI) Registration and Electronic Data Interchange (EDI) Enrollment Form; Use: The purpose of this... identification of Medicare providers/suppliers and authorization of requested Electronic Data Interface (EDI) functions. The EDI Enrollment and the Medicare Registration Forms are completed by Medicare providers...

  7. 31 CFR 501.801 - Licensing.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... organizations (“NGOs”), registration numbers may be issued on a case-by-case basis to NGOs involved in... NGO otherwise prohibited by the specific part with respect to which the registration number is issued... part for the purpose of relieving human suffering. The transactions authorized for registered NGOs...

  8. 31 CFR 501.801 - Licensing.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... organizations (“NGOs”), registration numbers may be issued on a case-by-case basis to NGOs involved in... NGO otherwise prohibited by the specific part with respect to which the registration number is issued... part for the purpose of relieving human suffering. The transactions authorized for registered NGOs...

  9. Validation of The Scenarios Designed For The Eu Registration of Pesticides

    NASA Astrophysics Data System (ADS)

    Piñeros Garcet, J. D.; de Nie, D.; Vanclooster, M.; Tiktak, A.; Klein, M.; Jones, A.

    As part of recent efforts to harmonise registration procedures for pesticides within the EU, a set of uniform principles were developed, setting out the detailed evaluation and decision making criteria for pesticide registration. The EU directive 91/414/EEC places great importance on the use of validated models to calculate Predicted Envi- ronmental Concentrations (PECs), as a basis for assessing the environmental risks and health effects. To be used in a harmonised registration process, the quality of PEC modelling needs to be assured. Quality assurance of mathematical modelling implies, amongst others, the validation of the environmental modelling scenarios. The FOrum for the CO-ordination of pesticide fate models and their USe (FOCUS), is the cur- rent platform where common modelling methodologies are designed and subjected for approval to the European authorities. In 2000, the FOCUS groundwater scenarios working group defined the procedures for realising tier 1 PEC groundwater calcula- tions for the active substances of plant protection products at the pan-european level. The procedures and guidelines were approved by the Standing Committee on Plant Health, and are now recommended for tier 1 PEC groundwater calculations in the reg- istration dossier. Yet, the working group also identified a range of uncertainties related to the validity of the present leaching scenarios. To mitigate some of these problems, the EU R&D project APECOP was designed and approved for support in the frame- work of the EU-FP5-Quality of Life Programme. One of the objectives of the project is to evaluate the appropriateness of the current Tier 1 groundwater scenarios. In this paper, we summarise the methodology and results of the scenarios validation.

  10. 3D-2D registration for surgical guidance: effect of projection view angles on registration accuracy

    NASA Astrophysics Data System (ADS)

    Uneri, A.; Otake, Y.; Wang, A. S.; Kleinszig, G.; Vogt, S.; Khanna, A. J.; Siewerdsen, J. H.

    2014-01-01

    An algorithm for intensity-based 3D-2D registration of CT and x-ray projections is evaluated, specifically using single- or dual-projection views to provide 3D localization. The registration framework employs the gradient information similarity metric and covariance matrix adaptation evolution strategy to solve for the patient pose in six degrees of freedom. Registration performance was evaluated in an anthropomorphic phantom and cadaver, using C-arm projection views acquired at angular separation, Δθ, ranging from ˜0°-180° at variable C-arm magnification. Registration accuracy was assessed in terms of 2D projection distance error and 3D target registration error (TRE) and compared to that of an electromagnetic (EM) tracker. The results indicate that angular separation as small as Δθ ˜10°-20° achieved TRE <2 mm with 95% confidence, comparable or superior to that of the EM tracker. The method allows direct registration of preoperative CT and planning data to intraoperative fluoroscopy, providing 3D localization free from conventional limitations associated with external fiducial markers, stereotactic frames, trackers and manual registration.

  11. 78 FR 52457 - Transfers of Operating Authority Registration

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-08-23

    ... 49 U.S.C. 10926 (63 FR 7362, February 13, 1998), a number of industry commenters objected, noting... authority and its corresponding USDOT Number remains connected with that operating authority, regardless of...

  12. Interindividual registration and dose mapping for voxelwise population analysis of rectal toxicity in prostate cancer radiotherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dréan, Gaël; Acosta, Oscar, E-mail: Oscar.Acosta@univ-rennes1.fr; Simon, Antoine

    2016-06-15

    Purpose: Recent studies revealed a trend toward voxelwise population analysis in order to understand the local dose/toxicity relationships in prostate cancer radiotherapy. Such approaches require, however, an accurate interindividual mapping of the anatomies and 3D dose distributions toward a common coordinate system. This step is challenging due to the high interindividual variability. In this paper, the authors propose a method designed for interindividual nonrigid registration of the rectum and dose mapping for population analysis. Methods: The method is based on the computation of a normalized structural description of the rectum using a Laplacian-based model. This description takes advantage of themore » tubular structure of the rectum and its centerline to be embedded in a nonrigid registration-based scheme. The performances of the method were evaluated on 30 individuals treated for prostate cancer in a leave-one-out cross validation. Results: Performance was measured using classical metrics (Dice score and Hausdorff distance), along with new metrics devised to better assess dose mapping in relation with structural deformation (dose-organ overlap). Considering these scores, the proposed method outperforms intensity-based and distance maps-based registration methods. Conclusions: The proposed method allows for accurately mapping interindividual 3D dose distributions toward a single anatomical template, opening the way for further voxelwise statistical analysis.« less

  13. 14 CFR 91.1015 - Management specifications.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... of all fractional owners and types of aircraft, registration markings and serial numbers; (2) The... other procedures under which each class and size of aircraft is to be operated; (4) Authorization for an inspection program approved under § 91.1109, including the type of aircraft, the registration markings and...

  14. 14 CFR 91.1015 - Management specifications.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... of all fractional owners and types of aircraft, registration markings and serial numbers; (2) The... other procedures under which each class and size of aircraft is to be operated; (4) Authorization for an inspection program approved under § 91.1109, including the type of aircraft, the registration markings and...

  15. 14 CFR 91.1015 - Management specifications.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... of all fractional owners and types of aircraft, registration markings and serial numbers; (2) The... other procedures under which each class and size of aircraft is to be operated; (4) Authorization for an inspection program approved under § 91.1109, including the type of aircraft, the registration markings and...

  16. 14 CFR 91.1015 - Management specifications.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... of all fractional owners and types of aircraft, registration markings and serial numbers; (2) The... other procedures under which each class and size of aircraft is to be operated; (4) Authorization for an inspection program approved under § 91.1109, including the type of aircraft, the registration markings and...

  17. 77 FR 35338 - Schedule of Fees Authorized

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-06-13

    ... registration program, to cover the cost of making import eligibility decisions, and to cover the cost of... establishes to cover the costs of ``making the decisions under this subchapter.'' This includes decisions on... for the cost of carrying out the registration program and making eligibility decisions, and to...

  18. 78 FR 64019 - Manufacturer of Controlled Substances, Notice of Registration, Austin Pharma, LLC.

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-10-25

    ... DEPARTMENT OF JUSTICE Drug Enforcement Administration Manufacturer of Controlled Substances... 78665-2402, made application by renewal to the Drug Enforcement Administration (DEA) to be registered as... this drug code is authorized for this registration. On August 9, 2013, Austin Pharma, LLC., withdrew...

  19. [Experiences and recommendations of the German Federal Institute for Drugs and Medical Devices (BfArM) concerning clinical investigation of medical devices and the evaluation of serious adverse events (SAE)].

    PubMed

    Renisch, B; Lauer, W

    2014-12-01

    An integral part of the conformity assessment process for medical devices is a clinical evaluation based on clinical data. Particularly in the case of implantable devices and products of risk class III clinical trials must be performed. Since March 2010 applications for the authorization of clinical trials as well as for the waiver of the authorization requirement must be submitted centrally in Germany to the appropriate federal authority, the Federal Institute for Drugs and Medical Devices (BfArM) or the Paul Ehrlich Institute (PEI). In addition to authorization, approval by the responsible ethics committee is also required under law in order to begin clinical testing of medical devices in Germany. In this paper, the legal framework for the clinical testing of medical devices as well as those involved and possible procedures including evaluation criteria for the initial application of a trial and subsequent amendments are presented in detail. In addition, the reporting requirements for serious adverse events (SAEs) are explained and possible consequences of the evaluation are presented. Finally, a summary of application and registration numbers for all areas of extensive experience of the BfArM as well as requests and guidance for applicants are presented.

  20. Open-source image registration for MRI-TRUS fusion-guided prostate interventions.

    PubMed

    Fedorov, Andriy; Khallaghi, Siavash; Sánchez, C Antonio; Lasso, Andras; Fels, Sidney; Tuncali, Kemal; Sugar, Emily Neubauer; Kapur, Tina; Zhang, Chenxi; Wells, William; Nguyen, Paul L; Abolmaesumi, Purang; Tempany, Clare

    2015-06-01

    We propose two software tools for non-rigid registration of MRI and transrectal ultrasound (TRUS) images of the prostate. Our ultimate goal is to develop an open-source solution to support MRI-TRUS fusion image guidance of prostate interventions, such as targeted biopsy for prostate cancer detection and focal therapy. It is widely hypothesized that image registration is an essential component in such systems. The two non-rigid registration methods are: (1) a deformable registration of the prostate segmentation distance maps with B-spline regularization and (2) a finite element-based deformable registration of the segmentation surfaces in the presence of partial data. We evaluate the methods retrospectively using clinical patient image data collected during standard clinical procedures. Computation time and Target Registration Error (TRE) calculated at the expert-identified anatomical landmarks were used as quantitative measures for the evaluation. The presented image registration tools were capable of completing deformable registration computation within 5 min. Average TRE was approximately 3 mm for both methods, which is comparable with the slice thickness in our MRI data. Both tools are available under nonrestrictive open-source license. We release open-source tools that may be used for registration during MRI-TRUS-guided prostate interventions. Our tools implement novel registration approaches and produce acceptable registration results. We believe these tools will lower the barriers in development and deployment of interventional research solutions and facilitate comparison with similar tools.

  1. Evaluation of 4-dimensional Computed Tomography to 4-dimensional Cone-Beam Computed Tomography Deformable Image Registration for Lung Cancer Adaptive Radiation Therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Balik, Salim; Weiss, Elisabeth; Jan, Nuzhat

    2013-06-01

    Purpose: To evaluate 2 deformable image registration (DIR) algorithms for the purpose of contour mapping to support image-guided adaptive radiation therapy with 4-dimensional cone-beam CT (4DCBCT). Methods and Materials: One planning 4D fan-beam CT (4DFBCT) and 7 weekly 4DCBCT scans were acquired for 10 locally advanced non-small cell lung cancer patients. The gross tumor volume was delineated by a physician in all 4D images. End-of-inspiration phase planning 4DFBCT was registered to the corresponding phase in weekly 4DCBCT images for day-to-day registrations. For phase-to-phase registration, the end-of-inspiration phase from each 4D image was registered to the end-of-expiration phase. Two DIR algorithms—smallmore » deformation inverse consistent linear elastic (SICLE) and Insight Toolkit diffeomorphic demons (DEMONS)—were evaluated. Physician-delineated contours were compared with the warped contours by using the Dice similarity coefficient (DSC), average symmetric distance, and false-positive and false-negative indices. The DIR results are compared with rigid registration of tumor. Results: For day-to-day registrations, the mean DSC was 0.75 ± 0.09 with SICLE, 0.70 ± 0.12 with DEMONS, 0.66 ± 0.12 with rigid-tumor registration, and 0.60 ± 0.14 with rigid-bone registration. Results were comparable to intraobserver variability calculated from phase-to-phase registrations as well as measured interobserver variation for 1 patient. SICLE and DEMONS, when compared with rigid-bone (4.1 mm) and rigid-tumor (3.6 mm) registration, respectively reduced the average symmetric distance to 2.6 and 3.3 mm. On average, SICLE and DEMONS increased the DSC to 0.80 and 0.79, respectively, compared with rigid-tumor (0.78) registrations for 4DCBCT phase-to-phase registrations. Conclusions: Deformable image registration achieved comparable accuracy to reported interobserver delineation variability and higher accuracy than rigid-tumor registration. Deformable image registration performance varied with the algorithm and the patient.« less

  2. 3D-2D registration in endovascular image-guided surgery: evaluation of state-of-the-art methods on cerebral angiograms.

    PubMed

    Mitrović, Uroš; Likar, Boštjan; Pernuš, Franjo; Špiclin, Žiga

    2018-02-01

    Image guidance for minimally invasive surgery is based on spatial co-registration and fusion of 3D pre-interventional images and treatment plans with the 2D live intra-interventional images. The spatial co-registration or 3D-2D registration is the key enabling technology; however, the performance of state-of-the-art automated methods is rather unclear as they have not been assessed under the same test conditions. Herein we perform a quantitative and comparative evaluation of ten state-of-the-art methods for 3D-2D registration on a public dataset of clinical angiograms. Image database consisted of 3D and 2D angiograms of 25 patients undergoing treatment for cerebral aneurysms or arteriovenous malformations. On each of the datasets, highly accurate "gold-standard" registrations of 3D and 2D images were established based on patient-attached fiducial markers. The database was used to rigorously evaluate ten state-of-the-art 3D-2D registration methods, namely two intensity-, two gradient-, three feature-based and three hybrid methods, both for registration of 3D pre-interventional image to monoplane or biplane 2D images. Intensity-based methods were most accurate in all tests (0.3 mm). One of the hybrid methods was most robust with 98.75% of successful registrations (SR) and capture range of 18 mm for registrations of 3D to biplane 2D angiograms. In general, registration accuracy was similar whether registration of 3D image was performed onto mono- or biplanar 2D images; however, the SR was substantially lower in case of 3D to monoplane 2D registration. Two feature-based and two hybrid methods had clinically feasible execution times in the order of a second. Performance of methods seems to fall below expectations in terms of robustness in case of registration of 3D to monoplane 2D images, while translation into clinical image guidance systems seems readily feasible for methods that perform registration of the 3D pre-interventional image onto biplanar intra-interventional 2D images.

  3. Fast and robust multimodal image registration using a local derivative pattern.

    PubMed

    Jiang, Dongsheng; Shi, Yonghong; Chen, Xinrong; Wang, Manning; Song, Zhijian

    2017-02-01

    Deformable multimodal image registration, which can benefit radiotherapy and image guided surgery by providing complementary information, remains a challenging task in the medical image analysis field due to the difficulty of defining a proper similarity measure. This article presents a novel, robust and fast binary descriptor, the discriminative local derivative pattern (dLDP), which is able to encode images of different modalities into similar image representations. dLDP calculates a binary string for each voxel according to the pattern of intensity derivatives in its neighborhood. The descriptor similarity is evaluated using the Hamming distance, which can be efficiently computed, instead of conventional L1 or L2 norms. For the first time, we validated the effectiveness and feasibility of the local derivative pattern for multimodal deformable image registration with several multi-modal registration applications. dLDP was compared with three state-of-the-art methods in artificial image and clinical settings. In the experiments of deformable registration between different magnetic resonance imaging (MRI) modalities from BrainWeb, between computed tomography and MRI images from patient data, and between MRI and ultrasound images from BITE database, we show our method outperforms localized mutual information and entropy images in terms of both accuracy and time efficiency. We have further validated dLDP for the deformable registration of preoperative MRI and three-dimensional intraoperative ultrasound images. Our results indicate that dLDP reduces the average mean target registration error from 4.12 mm to 2.30 mm. This accuracy is statistically equivalent to the accuracy of the state-of-the-art methods in the study; however, in terms of computational complexity, our method significantly outperforms other methods and is even comparable to the sum of the absolute difference. The results reveal that dLDP can achieve superior performance regarding both accuracy and time efficiency in general multimodal image registration. In addition, dLDP also indicates the potential for clinical ultrasound guided intervention. © 2016 The Authors. Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine.

  4. 29 CFR 500.55 - Changes to or amendments of certificate authority.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... REGULATIONS MIGRANT AND SEASONAL AGRICULTURAL WORKER PROTECTION Registration of Farm Labor Contractors and... of Registration is in effect, a farm labor contractor must apply to the Secretary to amend the... migrant or seasonal agricultural worker; or (3) Use, or cause to be used, another real property or...

  5. 14 CFR 294.21 - Procedure on receipt of registration form.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... Air Carrier Operating certificate and non-scheduled international license issued by the Government of... the Office of International Aviation, Special Authorities Division, and serve a copy on the applicant... expired, the Department will take one of the following actions: (1) Issue the registration by stamping its...

  6. 14 CFR 294.21 - Procedure on receipt of registration form.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... Air Carrier Operating certificate and non-scheduled international license issued by the Government of... the Office of International Aviation, Special Authorities Division, and serve a copy on the applicant... expired, the Department will take one of the following actions: (1) Issue the registration by stamping its...

  7. 14 CFR 294.21 - Procedure on receipt of registration form.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... Air Carrier Operating certificate and non-scheduled international license issued by the Government of... the Office of International Aviation, Special Authorities Division, and serve a copy on the applicant... expired, the Department will take one of the following actions: (1) Issue the registration by stamping its...

  8. 21 CFR 1301.19 - Special requirements for online pharmacies.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 9 2011-04-01 2011-04-01 false Special requirements for online pharmacies. 1301... Special requirements for online pharmacies. (a) A pharmacy that has been issued a registration under § 1301.13 may request that the Administrator modify its registration to authorize the pharmacy to...

  9. 21 CFR 1301.19 - Special requirements for online pharmacies.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 9 2013-04-01 2013-04-01 false Special requirements for online pharmacies. 1301... Special requirements for online pharmacies. (a) A pharmacy that has been issued a registration under § 1301.13 may request that the Administrator modify its registration to authorize the pharmacy to...

  10. 21 CFR 1301.19 - Special requirements for online pharmacies.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 9 2014-04-01 2014-04-01 false Special requirements for online pharmacies. 1301... Special requirements for online pharmacies. (a) A pharmacy that has been issued a registration under § 1301.13 may request that the Administrator modify its registration to authorize the pharmacy to...

  11. 21 CFR 1301.19 - Special requirements for online pharmacies.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 9 2012-04-01 2012-04-01 false Special requirements for online pharmacies. 1301... Special requirements for online pharmacies. (a) A pharmacy that has been issued a registration under § 1301.13 may request that the Administrator modify its registration to authorize the pharmacy to...

  12. 77 FR 29257 - Registration of Copyright: Definition of Claimant

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-05-17

    ... considerable legal uncertainty while offering no clear benefits to the registration system. Removing it will... individuals or entities that have obtained the contractual right to claim legal title to copyright in an... author, the contractual right to claim legal title to the copyright in an application for copyright...

  13. 21 CFR 1304.03 - Persons required to keep records and file reports.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... distributing registrant who utilizes a freight forwarding facility shall maintain records to reflect transfer... substances are shipped and authorized signatures for each transfer. A distributing registrant may, as part of the initial request to operate a freight forwarding facility, request permission to store records at a...

  14. 21 CFR 1304.03 - Persons required to keep records and file reports.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... distributing registrant who utilizes a freight forwarding facility shall maintain records to reflect transfer... substances are shipped and authorized signatures for each transfer. A distributing registrant may, as part of the initial request to operate a freight forwarding facility, request permission to store records at a...

  15. 21 CFR 1304.03 - Persons required to keep records and file reports.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... distributing registrant who utilizes a freight forwarding facility shall maintain records to reflect transfer... substances are shipped and authorized signatures for each transfer. A distributing registrant may, as part of the initial request to operate a freight forwarding facility, request permission to store records at a...

  16. 78 FR 78864 - Comparability Determination for Australia: Certain Entity-Level Requirements

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-12-27

    ... authority to support and enforce its oversight of the registrant. In this context, comparable does not... enforce its oversight of the registrant.\\18\\ \\18\\ 78 FR 45343. In making a comparability determination... effective systemic risk management for the overall swaps market. In making its comparability determination...

  17. 76 FR 44588 - Announcement of Requirements and Registration for “Using Public Data for Cancer Prevention and...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-07-26

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Announcement of Requirements and Registration for ``Using... Challenge'' is a challenge aimed at encouraging multidisciplinary teams of software developers... Human Services. The statutory authority for this challenge competition is Section 105 of the America...

  18. 21 CFR 1311.10 - Eligibility to obtain a CSOS digital certificate.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... obtain a CSOS digital certificate from the DEA Certification Authority to sign electronic orders for controlled substances. (a) The person who signed the most recent DEA registration application or renewal... by a DEA registrant to sign orders for one or more schedules of controlled substances. ...

  19. 47 CFR 87.103 - Posting station license.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... records. (b) Aircraft radio stations. The license must be either posted in the aircraft or kept with the aircraft registration certificate. If a single authorization covers a fleet of aircraft, a copy of the license must be either posted in each aircraft or kept with each aircraft registration certificate. (c...

  20. 47 CFR 87.103 - Posting station license.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... records. (b) Aircraft radio stations. The license must be either posted in the aircraft or kept with the aircraft registration certificate. If a single authorization covers a fleet of aircraft, a copy of the license must be either posted in each aircraft or kept with each aircraft registration certificate. (c...

  1. 47 CFR 87.103 - Posting station license.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... records. (b) Aircraft radio stations. The license must be either posted in the aircraft or kept with the aircraft registration certificate. If a single authorization covers a fleet of aircraft, a copy of the license must be either posted in each aircraft or kept with each aircraft registration certificate. (c...

  2. 47 CFR 87.103 - Posting station license.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... records. (b) Aircraft radio stations. The license must be either posted in the aircraft or kept with the aircraft registration certificate. If a single authorization covers a fleet of aircraft, a copy of the license must be either posted in each aircraft or kept with each aircraft registration certificate. (c...

  3. 47 CFR 87.103 - Posting station license.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... records. (b) Aircraft radio stations. The license must be either posted in the aircraft or kept with the aircraft registration certificate. If a single authorization covers a fleet of aircraft, a copy of the license must be either posted in each aircraft or kept with each aircraft registration certificate. (c...

  4. Developing a digital learning version of a mentorship training programme.

    PubMed

    Casey, Debbie; Clark, Liz; Gould, Kathryn

    2018-01-25

    This article describes the experience of one university team in developing, delivering and evaluating an online Nursing and Midwifery Council-approved mentorship programme for nurses and midwives who support pre-registration students in practice. Although the authors are confident of the quality of the educational provision, this article does not discuss this programme as an exemplar of best practice, but aims to share the learning gained from the experience of introducing a digital learning version of a mentorship course.

  5. Guidelines for evaluating the efficacy and safety of live anticoccidial vaccines, and obtaining approval for their use in chickens and turkeys.

    PubMed

    Chapman, H D; Roberts, B; Shirley, M W; Williams, R B

    2005-08-01

    These guidelines are intended to aid those engaged in poultry research in the design, implementation and interpretation of laboratory, floor-pen and field studies for the assessment of the efficacy and safety of live anticoccidial vaccines for immunization of chickens and turkeys against Eimeria species. In addition to efficacy and safety requirements, manufacture, quality control and licensing considerations are discussed. The guidelines do not address subunit vaccines comprising non-viable material, but many of the principles described will be relevant to such vaccines if they are developed in the future. Guidelines are available in some countries for avian vaccines of bacterial or viral origin but specific standards for anticoccidial vaccines in poultry have not, as far as we know, been produced. Information is provided on general requirements of registration authorities (based upon regulations applicable in the European Union and the USA) for obtaining marketing authorizations for vaccines. These guidelines may assist poultry specialists in providing specific information for administrators involved in the decision-making process leading to registration of new vaccines, and are intended to facilitate the worldwide adoption of consistent, standard procedures.

  6. Hand-eye calibration using a target registration error model.

    PubMed

    Chen, Elvis C S; Morgan, Isabella; Jayarathne, Uditha; Ma, Burton; Peters, Terry M

    2017-10-01

    Surgical cameras are prevalent in modern operating theatres and are often used as a surrogate for direct vision. Visualisation techniques (e.g. image fusion) made possible by tracking the camera require accurate hand-eye calibration between the camera and the tracking system. The authors introduce the concept of 'guided hand-eye calibration', where calibration measurements are facilitated by a target registration error (TRE) model. They formulate hand-eye calibration as a registration problem between homologous point-line pairs. For each measurement, the position of a monochromatic ball-tip stylus (a point) and its projection onto the image (a line) is recorded, and the TRE of the resulting calibration is predicted using a TRE model. The TRE model is then used to guide the placement of the calibration tool, so that the subsequent measurement minimises the predicted TRE. Assessing TRE after each measurement produces accurate calibration using a minimal number of measurements. As a proof of principle, they evaluated guided calibration using a webcam and an endoscopic camera. Their endoscopic camera results suggest that millimetre TRE is achievable when at least 15 measurements are acquired with the tracker sensor ∼80 cm away on the laparoscope handle for a target ∼20 cm away from the camera.

  7. Exploring the use of student-led simulated practice learning in pre-registration nursing programmes.

    PubMed

    Brown, Jo; Collins, Guy; Gratton, Olivia

    2017-09-20

    Simulated practice learning is used in pre-registration nursing programmes to replicate situations that nursing students are likely to encounter in clinical practice, but in a safe and protected academic environment. However, lecturer-led simulated practice learning has been perceived as detached from contemporary nursing practice by some nursing students. Therefore, a pilot project was implemented in the authors' university to explore the use of student-led simulated practice learning and its potential benefits for nursing students. To evaluate the effectiveness of student-led simulated practice learning in pre-registration nursing programmes. The authors specifically wanted to: enhance the students' skills; improve their critical thinking and reflective strategies; and develop their leadership and management techniques. A literature review was undertaken to examine the evidence supporting student-led simulated practice learning. A skills gap analysis was then conducted with 35 third-year nursing students to identify their learning needs, from which suitable simulated practice learning scenarios and sessions were developed and undertaken. These sessions were evaluated using debriefs following each of the sessions, as well as informal discussions with the nursing students. The pilot project identified that student-led simulated learning: developed nursing students' ability to plan and facilitate colleagues' practice learning; enabled nursing students to develop their mentoring skills; reinforced the nursing students' self-awareness, which contributed to their personal development; and demonstrated the importance of peer feedback and support through the debriefs. Challenges included overcoming some students' resistance to the project and that some lecturers were initially concerned that nursing students may not have the clinical expertise to lead the simulated practice learning sessions effectively. This pilot project has demonstrated how student-led simulated practice learning sessions could be used to engage nursing students as partners in their learning, enhance their knowledge and skills, and promote self-directed learning. ©2012 RCN Publishing Company Ltd. All rights reserved. Not to be copied, transmitted or recorded in any way, in whole or part, without prior permission of the publishers.

  8. Functional food and nutraceutical registration processes in Japan and China: a diffusion of innovation perspective.

    PubMed

    Patel, Darshika; Dufour, Yvon; Domigan, Neil

    2008-01-01

    Purpose - This paper looks into the functional food and nutraceutical registration processes in Japan and China. The Japanese have developed the Foods for Specified Health Use (FOSHU) registration process whereas the Chinese have put into place the Health Food (HF) registration process. The aim of this paper is to compare the regulation processes between the two countries in search for answers to three core empirical questions: (1) how have the registration processes developed and changed? (2) What are the similarities and differences between the processes of registration in the two countries investigated? (3) Why are the registration processes similar/different? Method - The study was conducted using secondary sources. The literature surveyed covered academic journals, trade journals, magazine and newspaper articles, market reports, proceedings, books and web pages of relevant regulatory authorities and regulatory consultants. Information from the more recently published sources was used preferentially over older sources. As well as using the most recent sources, information was selected on the basis of which source it was from. Official regulations and SFDA and MHLW websites would contain accurate and up to date information and information from here would be taken as true over other sources of information. Results - The two diagrams of the registration processes respectively in Japan and China clearly show that there are similarities and differences. There are six categories under which these can be found: (1) the scientific evidence required; (2) the application process; (3) the evaluation process; (4) the law and the categories of products; (5) the labels and the types of claims; and finally (6) the cost and the time involved. Conclusions -The data analysis suggests that the process of diffusion of innovation played a role in the development of the regulations. Further it was found that while Japan was at the outset a pioneer innovator in nutraceutical registration processes, there are indications that in more recent years it too imitated other countries. NOVELTY STATEMENT: The assortment of regulatory regimes creates much uncertainty for the firms and the lack of familiarity and poor knowledge of the regulatory situation increases the risk of failure. The research presented in this paper provides highly valuable information to any biotech/pharmaceutical/nutraceutical companies developing their market entry strategy in Japan and China. There are few national and international studies of drug registration application processes but even fewer comparative studies of functional food and neutraceutical registration application processes such as this one and none using a diffusion of innovation perspective.

  9. Endorsement of the CONSORT Statement by High-Impact Medical Journals in China: A Survey of Instructions for Authors and Published Papers

    PubMed Central

    Zhou, Qing-hui; Moher, David; Chen, Hong-yun; Wang, Fu-zhe; Ling, Chang-quan

    2012-01-01

    Background The CONSORT Statement is a reporting guideline for authors when reporting randomized controlled trials (RCTs). It offers a standard way for authors to prepare RCT reports. It has been endorsed by many high-impact medical journals and by international editorial groups. This study was conducted to assess the endorsement of the CONSORT Statement by high-impact medical journals in China by reviewing their instructions for authors. Methodology/Principal Findings A total of 200 medical journals were selected according to the Chinese Science and Technology Journal Citation Reports, 195 of which publish clinical research papers. Their instructions for authors were reviewed and all texts mentioning the CONSORT Statement or CONSORT extension papers were extracted. Any mention of the Uniform Requirements for Manuscripts Submitted to Biomedical Journals (URM) developed by the International Committee of Medical Journal Editors (ICMJE) or ‘clinical trial registration’ was also extracted. For journals endorsing the CONSORT Statement, their most recently published RCT reports were retrieved and evaluated to assess whether the journals have followed what the CONSORT Statement required. Out of the 195 medical journals publishing clinical research papers, only six (6/195, 3.08%) mentioned ‘CONSORT’ in their instructions for authors; out of the 200 medical journals surveyed, only 14 (14/200, 7.00%) mentioned ‘ICMJE’ or ‘URM’ in their instructions for authors, and another five journals stated in their instructions for authors that clinical trials should have trial registration numbers and that priority would be given to clinical trials which had been registered. Among the 62 RCT reports published in the six journals endorsing the CONSORT Statement, 20 (20/62, 32.26%) contained flow diagrams and only three (3/62, 4.84%) provided trial registration information. Conclusions/Significance Medical journals in China endorsing either the CONSORT Statement or the ICMJE's URM constituted a small percentage of the total; all of these journals used ambiguous language regarding what was expected of authors. PMID:22348017

  10. Multimodality Non-Rigid Image Registration for Planning, Targeting and Monitoring during CT-guided Percutaneous Liver Tumor Cryoablation

    PubMed Central

    Elhawary, Haytham; Oguro, Sota; Tuncali, Kemal; Morrison, Paul R.; Tatli, Servet; Shyn, Paul B.; Silverman, Stuart G.; Hata, Nobuhiko

    2010-01-01

    Rationale and Objectives To develop non-rigid image registration between pre-procedure contrast enhanced MR images and intra-procedure unenhanced CT images, to enhance tumor visualization and localization during CT-guided liver tumor cryoablation procedures. Materials and Methods After IRB approval, a non-rigid registration (NRR) technique was evaluated with different pre-processing steps and algorithm parameters and compared to a standard rigid registration (RR) approach. The Dice Similarity Coefficient (DSC), Target Registration Error (TRE), 95% Hausdorff distance (HD) and total registration time (minutes) were compared using a two-sided Student’s t-test. The entire registration method was then applied during five CT-guided liver cryoablation cases with the intra-procedural CT data transmitted directly from the CT scanner, with both accuracy and registration time evaluated. Results Selected optimal parameters for registration were section thickness of 5mm, cropping the field of view to 66% of its original size, manual segmentation of the liver, B-spline control grid of 5×5×5 and spatial sampling of 50,000 pixels. Mean 95% HD of 3.3mm (2.5x improvement compared to RR, p<0.05); mean DSC metric of 0.97 (13% increase); and mean TRE of 4.1mm (2.7x reduction) were measured. During the cryoablation procedure registration between the pre-procedure MR and the planning intra-procedure CT took a mean time of 10.6 minutes, the MR to targeting CT image took 4 minutes and MR to monitoring CT took 4.3 minutes. Mean registration accuracy was under 3.4mm. Conclusion Non-rigid registration allowed improved visualization of the tumor during interventional planning, targeting and evaluation of tumor coverage by the ice ball. Future work is focused on reducing segmentation time to make the method more clinically acceptable. PMID:20817574

  11. Clinical trial registration in oral health journals.

    PubMed

    Smaïl-Faugeron, V; Fron-Chabouis, H; Durieux, P

    2015-03-01

    Prospective registration of randomized controlled trials (RCTs) represents the best solution to reporting bias. The extent to which oral health journals have endorsed and complied with RCT registration is unknown. We identified journals publishing RCTs in dentistry, oral surgery, and medicine in the Journal Citation Reports. We classified journals into 3 groups: journals requiring or recommending trial registration, journals referring indirectly to registration, and journals providing no reference to registration. For the 5 journals with the highest 2012 impact factors in each group, we assessed whether RCTs with results published in 2013 had been registered. Of 78 journals examined, 32 (41%) required or recommended trial registration, 19 (24%) referred indirectly to registration, and 27 (35%) provided no reference to registration. We identified 317 RCTs with results published in the 15 selected journals in 2013. Overall, 73 (23%) were registered in a trial registry. Among those, 91% were registered retrospectively and 32% did not report trial registration in the published article. The proportion of trials registered was not significantly associated with editorial policies: 29% with results in journals that required or recommended registration, 15% in those that referred indirectly to registration, and 21% in those providing no reference to registration (P = 0.05). Less than one-quarter of RCTs with results published in a sample of oral health journals were registered with a public registry. Improvements are needed with respect to how journals inform and require their authors to register their trials. © International & American Associations for Dental Research.

  12. Quantitative Analysis Tools and Digital Phantoms for Deformable Image Registration Quality Assurance.

    PubMed

    Kim, Haksoo; Park, Samuel B; Monroe, James I; Traughber, Bryan J; Zheng, Yiran; Lo, Simon S; Yao, Min; Mansur, David; Ellis, Rodney; Machtay, Mitchell; Sohn, Jason W

    2015-08-01

    This article proposes quantitative analysis tools and digital phantoms to quantify intrinsic errors of deformable image registration (DIR) systems and establish quality assurance (QA) procedures for clinical use of DIR systems utilizing local and global error analysis methods with clinically realistic digital image phantoms. Landmark-based image registration verifications are suitable only for images with significant feature points. To address this shortfall, we adapted a deformation vector field (DVF) comparison approach with new analysis techniques to quantify the results. Digital image phantoms are derived from data sets of actual patient images (a reference image set, R, a test image set, T). Image sets from the same patient taken at different times are registered with deformable methods producing a reference DVFref. Applying DVFref to the original reference image deforms T into a new image R'. The data set, R', T, and DVFref, is from a realistic truth set and therefore can be used to analyze any DIR system and expose intrinsic errors by comparing DVFref and DVFtest. For quantitative error analysis, calculating and delineating differences between DVFs, 2 methods were used, (1) a local error analysis tool that displays deformation error magnitudes with color mapping on each image slice and (2) a global error analysis tool that calculates a deformation error histogram, which describes a cumulative probability function of errors for each anatomical structure. Three digital image phantoms were generated from three patients with a head and neck, a lung and a liver cancer. The DIR QA was evaluated using the case with head and neck. © The Author(s) 2014.

  13. Evaluating a community-based dental registration program for preschool children living in areas of high social deprivation.

    PubMed

    Yuan, S; Kerr, G; Salmon, K; Speedy, P; Freeman, R

    2007-03-01

    This was to evaluate the effectiveness of a community-based program to promote dental registration and access to dental services for preschool children residing in areas of high social deprivation using monthly registration data provided by the Central Services Agency (CSA). A quasi-experimental non-equivalent two group comparison. Areas of high social deprivation in the greater Belfast area. The dental registration program was conducted by community-based nurses (health visitors). The health visitors provided oral health education and distributed registration vouchers to mothers of new babies during home visits. The mothers exchanged the vouchers for motivational materials from the participating dental practices. Preschool child registration data were obtained from the CSA to evaluate the effectiveness of the program. The registration rates were significantly greater 5 months after the program for 0-2-year old children residing in the intervention wards compared with control wards. During the program the rate of change in registration for the 0-2-year-old group residing in the intervention wards was significantly greater compared with those residing in the control wards (t [DF:21]=4.26: p<0.001). There was a significant increase in registration rate 5 months after the program compared with 6 months before the study started for the 0-2 year old group residing in the intervention wards compared with those residing in the control wards (t [df: 21]=3.33: P=0.003). There were no equivalent effects for the 3-5-year old group. The adoption of a community-based approach assisted in promoting dental registration and access to dental services for preschool children residing in areas of high social deprivation.

  14. 8 CFR 1244.20 - Waiver of fees.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... TPS registration fee (including the fee for employment authorization, if applicable) shall be considered an essential expenditure. A fee waiver will be granted if the sum of the fees for TPS registration... inability to pay, he or she shall not deny a fee waiver due to the cost of administering the TPS program. (e...

  15. 8 CFR 1244.20 - Waiver of fees.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... TPS registration fee (including the fee for employment authorization, if applicable) shall be considered an essential expenditure. A fee waiver will be granted if the sum of the fees for TPS registration... inability to pay, he or she shall not deny a fee waiver due to the cost of administering the TPS program. (e...

  16. 8 CFR 1244.20 - Waiver of fees.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... TPS registration fee (including the fee for employment authorization, if applicable) shall be considered an essential expenditure. A fee waiver will be granted if the sum of the fees for TPS registration... inability to pay, he or she shall not deny a fee waiver due to the cost of administering the TPS program. (e...

  17. 8 CFR 1244.20 - Waiver of fees.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... TPS registration fee (including the fee for employment authorization, if applicable) shall be considered an essential expenditure. A fee waiver will be granted if the sum of the fees for TPS registration... inability to pay, he or she shall not deny a fee waiver due to the cost of administering the TPS program. (e...

  18. 8 CFR 1244.20 - Waiver of fees.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... TPS registration fee (including the fee for employment authorization, if applicable) shall be considered an essential expenditure. A fee waiver will be granted if the sum of the fees for TPS registration... inability to pay, he or she shall not deny a fee waiver due to the cost of administering the TPS program. (e...

  19. 21 CFR 1301.23 - Exemption of certain military and other personnel.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... Health Service, or Bureau of Prisons who is authorized to prescribe, dispense, or administer, but not to... exempted by this section also engages as a private individual in any activity or group of activities for which registration is required, such official shall obtain a registration for such private activities...

  20. 21 CFR 1301.23 - Exemption of certain military and other personnel.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... Health Service, or Bureau of Prisons who is authorized to prescribe, dispense, or administer, but not to... exempted by this section also engages as a private individual in any activity or group of activities for which registration is required, such official shall obtain a registration for such private activities...

  1. 21 CFR 1301.23 - Exemption of certain military and other personnel.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... Health Service, or Bureau of Prisons who is authorized to prescribe, dispense, or administer, but not to... exempted by this section also engages as a private individual in any activity or group of activities for which registration is required, such official shall obtain a registration for such private activities...

  2. 21 CFR 1301.23 - Exemption of certain military and other personnel.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... Health Service, or Bureau of Prisons who is authorized to prescribe, dispense, or administer, but not to... exempted by this section also engages as a private individual in any activity or group of activities for which registration is required, such official shall obtain a registration for such private activities...

  3. 21 CFR 1301.23 - Exemption of certain military and other personnel.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... Health Service, or Bureau of Prisons who is authorized to prescribe, dispense, or administer, but not to... exempted by this section also engages as a private individual in any activity or group of activities for which registration is required, such official shall obtain a registration for such private activities...

  4. 32 CFR 935.13 - Revocation or suspension of permits and registrations.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... registrations. 935.13 Section 935.13 National Defense Department of Defense (Continued) DEPARTMENT OF THE AIR FORCE TERRITORIAL AND INSULAR REGULATIONS WAKE ISLAND CODE Civil Administration Authority § 935.13... reasons, within 30 days thereafter. (d) If a hearing is not granted within 30 days, a written decision is...

  5. Collateral Consequences of Juvenile Sex Offender Registration and Notification: Results From a Survey of Treatment Providers.

    PubMed

    Harris, Andrew J; Walfield, Scott M; Shields, Ryan T; Letourneau, Elizabeth J

    2016-12-01

    Among many in the research, policy, and practice communities, the application of sex offender registration and notification (SORN) to juveniles who sexually offend (JSO) has raised ongoing concerns regarding the potential collateral impacts on youths' social, mental health, and academic adjustment. To date, however, no published research has systematically examined these types of collateral consequences of juvenile SORN. Based on a survey of a national sample of treatment providers in the United States, this study investigates the perceived impact of registration and notification on JSO across five key domains: mental health, harassment and unfair treatment, school problems, living instability, and risk of reoffending. Results indicate that treatment providers overwhelmingly perceive negative consequences associated with registration with an incremental effect of notification indicating even greater concern across all five domains. Providers' demographics, treatment modalities, and client profile did not influence their perceptions of the collateral consequences suggesting that provider concern about the potential harm of SORN applied to juveniles is robust. Policy implications are discussed. © The Author(s) 2015.

  6. Patient portal doldrums: does an exam room promotional video during an office visit increase patient portal registrations and portal use?

    PubMed

    North, Frederick; Hanna, Barbara K; Crane, Sarah J; Smith, Steven A; Tulledge-Scheitel, Sidna M; Stroebel, Robert J

    2011-12-01

    The patient portal is a web service which allows patients to view their electronic health record, communicate online with their care teams, and manage healthcare appointments and medications. Despite advantages of the patient portal, registrations for portal use have often been slow. Using a secure video system on our existing exam room electronic health record displays during regular office visits, the authors showed patients a video which promoted use of the patient portal. The authors compared portal registrations and portal use following the video to providing a paper instruction sheet and to a control (no additional portal promotion). From the 12,050 office appointments examined, portal registrations within 45 days of the appointment were 11.7%, 7.1%, and 2.5% for video, paper instructions, and control respectively (p<0.0001). Within 6 months following the interventions, 3.5% in the video cohort, 1.2% in the paper, and 0.75% of the control patients demonstrated portal use by initiating portal messages to their providers (p<0.0001).

  7. Effect of iris registration on outcomes of FEMTOLASIK for myopia and myopic astigmatism.

    PubMed

    Ghoreishi, Mohammad; Beni, Zahra Naderi; Beni, Afsaneh Naderi; Kianersi, Farzan

    2017-09-05

    To compare the visual and refractive outcomes after FEMTOLASIK with and without iris registration. In this randomized, prospective, comparative, contralateral eye study, 118 eyes of 59 patients with myopia and myopic astigmatism underwent LASIK using the Femto LDV femtosecond laser (160 µm) and the MEL80 with or without iris registration. For each patient, iris registration FEMTOLASIK was performed on one eye and non-iris registration FEMTOLASIK was performed on the other eye, assigned at random. Patients were evaluated before and 12 months. Uncorrected visual acuity, best-corrected visual acuity, manifest refraction, contrast sensitivity, and higher-order aberrations (HOAs) were evaluated. At 12 months, the mean UDVA was 0.002 ± 0.07 logMAR (20/19) in iris registration eyes and 0.00 ± 0.06 logMAR (20/24) in non-iris registration eyes (P = 0.9). 61% of iris registration eyes and 71.2% of non-iris registration eyes achieved a UDVA of 20/20 or better (P = 0.31); 98.3% of eyes with the iris registration FEMTOLASIK and 94.9% with the non-iris registration FEMTOLASIK were within ±0.50 D from emmetropia (P = 0.71). No statistically significant difference was found in postoperative contrast sensitivity between groups at 3, 6, 12, or 18 cycles/degree (P > 0.05). There was significant increase in total HOA root mean square in two groups. The mean error magnitude of surgically induced astigmatism 12 months postoperatively was -0.33 in iris registration eyes and -0.24 in the non-iris registration eyes (P = 0.36). FEMTOLASIK with and without iris registration provides similar results in myopic and myopic astigmatism patients.

  8. Non-invasive breast biopsy method using GD-DTPA contrast enhanced MRI series and F-18-FDG PET/CT dynamic image series

    NASA Astrophysics Data System (ADS)

    Magri, Alphonso William

    This study was undertaken to develop a nonsurgical breast biopsy from Gd-DTPA Contrast Enhanced Magnetic Resonance (CE-MR) images and F-18-FDG PET/CT dynamic image series. A five-step process was developed to accomplish this. (1) Dynamic PET series were nonrigidly registered to the initial frame using a finite element method (FEM) based registration that requires fiducial skin markers to sample the displacement field between image frames. A commercial FEM package (ANSYS) was used for meshing and FEM calculations. Dynamic PET image series registrations were evaluated using similarity measurements SAVD and NCC. (2) Dynamic CE-MR series were nonrigidly registered to the initial frame using two registration methods: a multi-resolution free-form deformation (FFD) registration driven by normalized mutual information, and a FEM-based registration method. Dynamic CE-MR image series registrations were evaluated using similarity measurements, localization measurements, and qualitative comparison of motion artifacts. FFD registration was found to be superior to FEM-based registration. (3) Nonlinear curve fitting was performed for each voxel of the PET/CT volume of activity versus time, based on a realistic two-compartmental Patlak model. Three parameters for this model were fitted; two of them describe the activity levels in the blood and in the cellular compartment, while the third characterizes the washout rate of F-18-FDG from the cellular compartment. (4) Nonlinear curve fitting was performed for each voxel of the MR volume of signal intensity versus time, based on a realistic two-compartment Brix model. Three parameters for this model were fitted: rate of Gd exiting the compartment, representing the extracellular space of a lesion; rate of Gd exiting a blood compartment; and a parameter that characterizes the strength of signal intensities. Curve fitting used for PET/CT and MR series was accomplished by application of the Levenburg-Marquardt nonlinear regression algorithm. The best-fit parameters were used to create 3D parametric images. Compartmental modeling evaluation was based on the ability of parameter values to differentiate between tissue types. This evaluation was used on registered and unregistered image series and found that registration improved results. (5) PET and MR parametric images were registered through FEM- and FFD-based registration. Parametric image registration was evaluated using similarity measurements, target registration error, and qualitative comparison. Comparing FFD and FEM-based registration results showed that the FEM method is superior. This five-step process constitutes a novel multifaceted approach to a nonsurgical breast biopsy that successfully executes each step. Comparison of this method to biopsy still needs to be done with a larger set of subject data.

  9. 47 CFR 76.29 - Special temporary authority.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 47 Telecommunication 4 2012-10-01 2012-10-01 false Special temporary authority. 76.29 Section 76.29 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) BROADCAST RADIO SERVICES MULTICHANNEL VIDEO AND CABLE TELEVISION SERVICE Registration Statements § 76.29 Special temporary authority. (a...

  10. 47 CFR 76.29 - Special temporary authority.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 47 Telecommunication 4 2011-10-01 2011-10-01 false Special temporary authority. 76.29 Section 76.29 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) BROADCAST RADIO SERVICES MULTICHANNEL VIDEO AND CABLE TELEVISION SERVICE Registration Statements § 76.29 Special temporary authority. (a...

  11. 47 CFR 76.29 - Special temporary authority.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 47 Telecommunication 4 2013-10-01 2013-10-01 false Special temporary authority. 76.29 Section 76.29 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) BROADCAST RADIO SERVICES MULTICHANNEL VIDEO AND CABLE TELEVISION SERVICE Registration Statements § 76.29 Special temporary authority. (a...

  12. 47 CFR 76.29 - Special temporary authority.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 47 Telecommunication 4 2014-10-01 2014-10-01 false Special temporary authority. 76.29 Section 76.29 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) BROADCAST RADIO SERVICES MULTICHANNEL VIDEO AND CABLE TELEVISION SERVICE Registration Statements § 76.29 Special temporary authority. (a...

  13. Pre-processing, registration and selection of adaptive optics corrected retinal images.

    PubMed

    Ramaswamy, Gomathy; Devaney, Nicholas

    2013-07-01

    In this paper, the aim is to demonstrate enhanced processing of sequences of fundus images obtained using a commercial AO flood illumination system. The purpose of the work is to (1) correct for uneven illumination at the retina (2) automatically select the best quality images and (3) precisely register the best images. Adaptive optics corrected retinal images are pre-processed to correct uneven illumination using different methods; subtracting or dividing by the average filtered image, homomorphic filtering and a wavelet based approach. These images are evaluated to measure the image quality using various parameters, including sharpness, variance, power spectrum kurtosis and contrast. We have carried out the registration in two stages; a coarse stage using cross-correlation followed by fine registration using two approaches; parabolic interpolation on the peak of the cross-correlation and maximum-likelihood estimation. The angle of rotation of the images is measured using a combination of peak tracking and Procrustes transformation. We have found that a wavelet approach (Daubechies 4 wavelet at 6th level decomposition) provides good illumination correction with clear improvement in image sharpness and contrast. The assessment of image quality using a 'Designer metric' works well when compared to visual evaluation, although it is highly correlated with other metrics. In image registration, sub-pixel translation measured using parabolic interpolation on the peak of the cross-correlation function and maximum-likelihood estimation are found to give very similar results (RMS difference 0.047 pixels). We have confirmed that correcting rotation of the images provides a significant improvement, especially at the edges of the image. We observed that selecting the better quality frames (e.g. best 75% images) for image registration gives improved resolution, at the expense of poorer signal-to-noise. The sharpness map of the registered and de-rotated images shows increased sharpness over most of the field of view. Adaptive optics assisted images of the cone photoreceptors can be better pre-processed using a wavelet approach. These images can be assessed for image quality using a 'Designer Metric'. Two-stage image registration including correcting for rotation significantly improves the final image contrast and sharpness. © 2013 The Authors Ophthalmic & Physiological Optics © 2013 The College of Optometrists.

  14. Nursing sans frontières: a three year case study of multi-state registration to support nursing practice using information technology.

    PubMed

    Clark, Robyn A; Yallop, Julie; Wickett, Di; Krum, Henry; Tonkin, Andrew; Stewart, Simon

    2006-01-01

    To highlight the registration issues for nurses who wish to practice nationally, particularly those practicing within the telehealth sector. As part of a national clinical research study, applications were made to every state and territory for mutual recognition of nursing registration and fee waiver for telenursing cross border practice for a period of three years. These processes are described using a case study approach. The aim of this case study was to achieve registration in every state and territory of Australia without paying multiple fees by using mutual recognition provisions and the cross-border fee waiver policy of the nurse regulatory authorities in order to practice telenursing. Mutual recognition and fee waiver for cross-border practice was granted unconditionally in two states: Victoria (Vic) and Tasmania (Tas), and one territory: the Northern Territory (NT). The remainder of the Australian states and territories would only grant temporary registration for the period of the project or not at all, due to policy restrictions or nurse regulatory authority (NRA) Board decisions. As a consequence of gaining fee waiver the annual cost of registration was a maximum of dollars 145 per annum as opposed to the potential dollars 959 for initial registration and dollars 625 for annual renewal. Having eight individual nurses Acts and NRAs for a population of 265,000 nurses would clearly indicate a case for over regulation in this country. The structure of regulation of nursing in Australia is a barrier to the changing and evolving role of nurses in the 21st century and a significant factor when considering workforce planning.

  15. User Registration Systems for Distributed Systems

    NASA Astrophysics Data System (ADS)

    Murphy, K. J.; Cechini, M.; Pilone, D.; Mitchell, A.

    2010-12-01

    As NASA’s Earth Observing System Data and Information System (EOSDIS) systems have evolved over the years, most of the EOSDIS data are now available to users via anonymous on-line access. Although the changes have improved the dissemination efficiency of earth science data, the anonymous access has made it difficult to characterize users, capture metrics on the value of EOSDIS and provide customized services that benefit users. As the number of web-based applications continues to grow, data centers and application providers have implemented their own user registration systems and provided new tools and interfaces for their registered users. This has led to the creation of independent registration systems for accessing data and interacting with online tools and services. The user profile information maintained at each of these registration systems is not consistent and the registration enforcement varies by system as well. This problem is in no way unique to EOSDIS and represents a general challenge to the distributed computing community. In a study done in 2007(http://www2007.org/papers/paper620.pd), the average user has approximately 7 passwords for about 25 accounts and enters a password 8 times a day. These numbers have only increased in the last three years. To try and address this, a number of solutions have been offered including Single Sign-On solutions using a common backend like Microsoft Active Directory or an LDAP server, trust based identity providers like OpenID, and various forms of authorization delegation like OAuth or SAML/XACML. This talk discusses the differences between authentication and authorization, the state of the more popular user registration solutions available for distributed use, and some of the technical and policy drivers that need to be considered when incorporating a user registration system into your application.

  16. 75 FR 8102 - Proposed Information Collection; OMB Control Number 1018-0137; Applications for Single Use...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-02-23

    ... Registration of Production Facilities (CITES) AGENCY: Fish and Wildlife Service, Interior. ACTION: Notice... to the import or export of CITES-listed species, the Management Authority and Scientific Authority... and U.S. Scientific Authority for CITES. The Secretary delegated these authorities to the Fish and...

  17. 77 FR 46147 - FMCSA Policy on Granting, Withholding, Suspending, Amending or Revoking Operating Authority...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-08-02

    ... (establishing standards for issuing operating authority) and 49 U.S.C. 13905 (establishing standards and procedures for suspending and revoking operating authority). Additionally, ICCTA section 204 contains a... decision to reject its application and withhold operating authority registration in writing. The rejection...

  18. Student Evaluation of Summer Orientation, Learning, Advising, and Registration.

    ERIC Educational Resources Information Center

    Allen, David F.

    Incoming freshmen at the University of North Carolina at Wilmington completed evaluations of their two-day orientation. The Orientation Evaluation is administered to freshmen who have chosen to participate in one of three sessions: Summer Orientation, Learning, Advising, and Registration sessions (SOLAR). A total of 166 students completed the…

  19. Multimodal Image Registration through Simultaneous Segmentation.

    PubMed

    Aganj, Iman; Fischl, Bruce

    2017-11-01

    Multimodal image registration facilitates the combination of complementary information from images acquired with different modalities. Most existing methods require computation of the joint histogram of the images, while some perform joint segmentation and registration in alternate iterations. In this work, we introduce a new non-information-theoretical method for pairwise multimodal image registration, in which the error of segmentation - using both images - is considered as the registration cost function. We empirically evaluate our method via rigid registration of multi-contrast brain magnetic resonance images, and demonstrate an often higher registration accuracy in the results produced by the proposed technique, compared to those by several existing methods.

  20. Quantum key management

    DOEpatents

    Hughes, Richard John; Thrasher, James Thomas; Nordholt, Jane Elizabeth

    2016-11-29

    Innovations for quantum key management harness quantum communications to form a cryptography system within a public key infrastructure framework. In example implementations, the quantum key management innovations combine quantum key distribution and a quantum identification protocol with a Merkle signature scheme (using Winternitz one-time digital signatures or other one-time digital signatures, and Merkle hash trees) to constitute a cryptography system. More generally, the quantum key management innovations combine quantum key distribution and a quantum identification protocol with a hash-based signature scheme. This provides a secure way to identify, authenticate, verify, and exchange secret cryptographic keys. Features of the quantum key management innovations further include secure enrollment of users with a registration authority, as well as credential checking and revocation with a certificate authority, where the registration authority and/or certificate authority can be part of the same system as a trusted authority for quantum key distribution.

  1. Adaptive Diffeomorphic Multiresolution Demons and Their Application to Same Modality Medical Image Registration with Large Deformation

    PubMed Central

    Wang, Chang; Ren, Qiongqiong; Qin, Xin

    2018-01-01

    Diffeomorphic demons can guarantee smooth and reversible deformation and avoid unreasonable deformation. However, the number of iterations needs to be set manually, and this greatly influences the registration result. In order to solve this problem, we proposed adaptive diffeomorphic multiresolution demons in this paper. We used an optimized framework with nonrigid registration and diffeomorphism strategy, designed a similarity energy function based on grey value, and stopped iterations adaptively. This method was tested by synthetic image and same modality medical image. Large deformation was simulated by rotational distortion and extrusion transform, medical image registration with large deformation was performed, and quantitative analyses were conducted using the registration evaluation indexes, and the influence of different driving forces and parameters on the registration result was analyzed. The registration results of same modality medical images were compared with those obtained using active demons, additive demons, and diffeomorphic demons. Quantitative analyses showed that the proposed method's normalized cross-correlation coefficient and structural similarity were the highest and mean square error was the lowest. Medical image registration with large deformation could be performed successfully; evaluation indexes remained stable with an increase in deformation strength. The proposed method is effective and robust, and it can be applied to nonrigid registration of same modality medical images with large deformation.

  2. Adaptive Diffeomorphic Multiresolution Demons and Their Application to Same Modality Medical Image Registration with Large Deformation.

    PubMed

    Wang, Chang; Ren, Qiongqiong; Qin, Xin; Yu, Yi

    2018-01-01

    Diffeomorphic demons can guarantee smooth and reversible deformation and avoid unreasonable deformation. However, the number of iterations needs to be set manually, and this greatly influences the registration result. In order to solve this problem, we proposed adaptive diffeomorphic multiresolution demons in this paper. We used an optimized framework with nonrigid registration and diffeomorphism strategy, designed a similarity energy function based on grey value, and stopped iterations adaptively. This method was tested by synthetic image and same modality medical image. Large deformation was simulated by rotational distortion and extrusion transform, medical image registration with large deformation was performed, and quantitative analyses were conducted using the registration evaluation indexes, and the influence of different driving forces and parameters on the registration result was analyzed. The registration results of same modality medical images were compared with those obtained using active demons, additive demons, and diffeomorphic demons. Quantitative analyses showed that the proposed method's normalized cross-correlation coefficient and structural similarity were the highest and mean square error was the lowest. Medical image registration with large deformation could be performed successfully; evaluation indexes remained stable with an increase in deformation strength. The proposed method is effective and robust, and it can be applied to nonrigid registration of same modality medical images with large deformation.

  3. Three-Dimensional Registration for Handheld Profiling Systems Based on Multiple Shot Structured Light

    PubMed Central

    Ayaz, Shirazi Muhammad; Kim, Min Young

    2018-01-01

    In this article, a multi-view registration approach for the 3D handheld profiling system based on the multiple shot structured light technique is proposed. The multi-view registration approach is categorized into coarse registration and point cloud refinement using the iterative closest point (ICP) algorithm. Coarse registration of multiple point clouds was performed using relative orientation and translation parameters estimated via homography-based visual navigation. The proposed system was evaluated using an artificial human skull and a paper box object. For the quantitative evaluation of the accuracy of a single 3D scan, a paper box was reconstructed, and the mean errors in its height and breadth were found to be 9.4 μm and 23 μm, respectively. A comprehensive quantitative evaluation and comparison of proposed algorithm was performed with other variants of ICP. The root mean square error for the ICP algorithm to register a pair of point clouds of the skull object was also found to be less than 1 mm. PMID:29642552

  4. Technical note: DIRART--A software suite for deformable image registration and adaptive radiotherapy research.

    PubMed

    Yang, Deshan; Brame, Scott; El Naqa, Issam; Aditya, Apte; Wu, Yu; Goddu, S Murty; Mutic, Sasa; Deasy, Joseph O; Low, Daniel A

    2011-01-01

    Recent years have witnessed tremendous progress in image guide radiotherapy technology and a growing interest in the possibilities for adapting treatment planning and delivery over the course of treatment. One obstacle faced by the research community has been the lack of a comprehensive open-source software toolkit dedicated for adaptive radiotherapy (ART). To address this need, the authors have developed a software suite called the Deformable Image Registration and Adaptive Radiotherapy Toolkit (DIRART). DIRART is an open-source toolkit developed in MATLAB. It is designed in an object-oriented style with focus on user-friendliness, features, and flexibility. It contains four classes of DIR algorithms, including the newer inverse consistency algorithms to provide consistent displacement vector field in both directions. It also contains common ART functions, an integrated graphical user interface, a variety of visualization and image-processing features, dose metric analysis functions, and interface routines. These interface routines make DIRART a powerful complement to the Computational Environment for Radiotherapy Research (CERR) and popular image-processing toolkits such as ITK. DIRART provides a set of image processing/registration algorithms and postprocessing functions to facilitate the development and testing of DIR algorithms. It also offers a good amount of options for DIR results visualization, evaluation, and validation. By exchanging data with treatment planning systems via DICOM-RT files and CERR, and by bringing image registration algorithms closer to radiotherapy applications, DIRART is potentially a convenient and flexible platform that may facilitate ART and DIR research. 0 2011 Ameri-

  5. Guidelines, Criteria and Regulations for the Registration of Units and Qualifications for National Certificates and National Diplomas. Quality Assurance in Education and Training.

    ERIC Educational Resources Information Center

    New Zealand Qualifications Authority, Wellington.

    This booklet contains guidelines for the registration of units and qualifications in New Zealand's National Qualifications Framework, a system of education and employment qualifications. An introduction provides an overview of registration, including endorsement, evaluation, and reregistration. Section 2 focuses on registration of unit standards.…

  6. Automated bone segmentation from dental CBCT images using patch-based sparse representation and convex optimization

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, Li; Gao, Yaozong; Shi, Feng

    Purpose: Cone-beam computed tomography (CBCT) is an increasingly utilized imaging modality for the diagnosis and treatment planning of the patients with craniomaxillofacial (CMF) deformities. Accurate segmentation of CBCT image is an essential step to generate three-dimensional (3D) models for the diagnosis and treatment planning of the patients with CMF deformities. However, due to the poor image quality, including very low signal-to-noise ratio and the widespread image artifacts such as noise, beam hardening, and inhomogeneity, it is challenging to segment the CBCT images. In this paper, the authors present a new automatic segmentation method to address these problems. Methods: To segmentmore » CBCT images, the authors propose a new method for fully automated CBCT segmentation by using patch-based sparse representation to (1) segment bony structures from the soft tissues and (2) further separate the mandible from the maxilla. Specifically, a region-specific registration strategy is first proposed to warp all the atlases to the current testing subject and then a sparse-based label propagation strategy is employed to estimate a patient-specific atlas from all aligned atlases. Finally, the patient-specific atlas is integrated into amaximum a posteriori probability-based convex segmentation framework for accurate segmentation. Results: The proposed method has been evaluated on a dataset with 15 CBCT images. The effectiveness of the proposed region-specific registration strategy and patient-specific atlas has been validated by comparing with the traditional registration strategy and population-based atlas. The experimental results show that the proposed method achieves the best segmentation accuracy by comparison with other state-of-the-art segmentation methods. Conclusions: The authors have proposed a new CBCT segmentation method by using patch-based sparse representation and convex optimization, which can achieve considerably accurate segmentation results in CBCT segmentation based on 15 patients.« less

  7. α-Information Based Registration of Dynamic Scans for Magnetic Resonance Cystography

    PubMed Central

    Han, Hao; Lin, Qin; Li, Lihong; Duan, Chaijie; Lu, Hongbing; Li, Haifang; Yan, Zengmin; Fitzgerald, John

    2015-01-01

    To continue our effort on developing magnetic resonance (MR) cystography, we introduce a novel non–rigid 3D registration method to compensate for bladder wall motion and deformation in dynamic MR scans, which are impaired by relatively low signal–to–noise ratio in each time frame. The registration method is developed on the similarity measure of α–information, which has the potential of achieving higher registration accuracy than the commonly-used mutual information (MI) measure for either mono-modality or multi-modality image registration. The α–information metric was also demonstrated to be superior to both the mean squares and the cross-correlation metrics in multi-modality scenarios. The proposed α–registration method was applied for bladder motion compensation via real patient studies, and its effect to the automatic and accurate segmentation of bladder wall was also evaluated. Compared with the prevailing MI-based image registration approach, the presented α–information based registration was more effective to capture the bladder wall motion and deformation, which ensured the success of the following bladder wall segmentation to achieve the goal of evaluating the entire bladder wall for detection and diagnosis of abnormality. PMID:26087506

  8. Problematic but Possible: Online Teaching and Learning in Post-Registration Programmes

    ERIC Educational Resources Information Center

    Cassar, Maria; Trapani, Josef

    2014-01-01

    This artifact identifies the main challenges experienced by the authors, both nurse educators, in the delivery of a module on evidence based practice exclusively through the use of an e-learning platform. The module has been running for the past four years as part of an entirely online post registration programme for qualified health professionals…

  9. Project Management Series Case Study: The Office of Registration and Records

    ERIC Educational Resources Information Center

    Burgher, Karl E.; Snyder, Michael

    2012-01-01

    This is the third in a series of eight articles on project management (PM) in the academy. In this article, the authors describe the step-by-step implementation of a structural change to Indiana State University's (ISU's) Office of Registration and Records (ORR). The process described may vary as it is implemented elsewhere, but the authors…

  10. 26 CFR 48.4081-5 - Taxable fuel; notification certificate of taxable fuel registrant.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... authority to bind the registrant, is in substantially the same form as the model provided in paragraph (b)(2) of this section, and contains all information necessary to complete such model. A new certificate... be included as part of any business records normally used to document a sale. The certificate expires...

  11. 49 CFR 385.305 - What happens after the FMCSA receives a request for new entrant registration?

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... the FMCSA Internet website (www.fmcsa.dot.gov) to secure and/or complete the application package... appropriate. (c) Upon completion of the application forms, the new entrant will be issued a USDOT number. (d.... (2) Form MCSA-1—FMCSA Registration/Update (USDOT Number—Operating Authority Application). This form...

  12. 49 CFR 385.305 - What happens after the FMCSA receives a request for new entrant registration?

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... the FMCSA Internet website (www.fmcsa.dot.gov) to secure and/or complete the application package... appropriate. (c) Upon completion of the application forms, the new entrant will be issued a USDOT number. (d.... (2) Form MCSA-1—FMCSA Registration/Update (USDOT Number—Operating Authority Application). This form...

  13. EVALUATION OF REGISTRATION, COMPRESSION AND CLASSIFICATION ALGORITHMS

    NASA Technical Reports Server (NTRS)

    Jayroe, R. R.

    1994-01-01

    Several types of algorithms are generally used to process digital imagery such as Landsat data. The most commonly used algorithms perform the task of registration, compression, and classification. Because there are different techniques available for performing registration, compression, and classification, imagery data users need a rationale for selecting a particular approach to meet their particular needs. This collection of registration, compression, and classification algorithms was developed so that different approaches could be evaluated and the best approach for a particular application determined. Routines are included for six registration algorithms, six compression algorithms, and two classification algorithms. The package also includes routines for evaluating the effects of processing on the image data. This collection of routines should be useful to anyone using or developing image processing software. Registration of image data involves the geometrical alteration of the imagery. Registration routines available in the evaluation package include image magnification, mapping functions, partitioning, map overlay, and data interpolation. The compression of image data involves reducing the volume of data needed for a given image. Compression routines available in the package include adaptive differential pulse code modulation, two-dimensional transforms, clustering, vector reduction, and picture segmentation. Classification of image data involves analyzing the uncompressed or compressed image data to produce inventories and maps of areas of similar spectral properties within a scene. The classification routines available include a sequential linear technique and a maximum likelihood technique. The choice of the appropriate evaluation criteria is quite important in evaluating the image processing functions. The user is therefore given a choice of evaluation criteria with which to investigate the available image processing functions. All of the available evaluation criteria basically compare the observed results with the expected results. For the image reconstruction processes of registration and compression, the expected results are usually the original data or some selected characteristics of the original data. For classification processes the expected result is the ground truth of the scene. Thus, the comparison process consists of determining what changes occur in processing, where the changes occur, how much change occurs, and the amplitude of the change. The package includes evaluation routines for performing such comparisons as average uncertainty, average information transfer, chi-square statistics, multidimensional histograms, and computation of contingency matrices. This collection of routines is written in FORTRAN IV for batch execution and has been implemented on an IBM 360 computer with a central memory requirement of approximately 662K of 8 bit bytes. This collection of image processing and evaluation routines was developed in 1979.

  14. Medico-economic evaluation of health products in the context of the Social Security Financing Act for 2012.

    PubMed

    Dervaux, Benoît; Baseilhac, Eric; Fagon, Jean-Yves; Ameye, Véronique; Angot, Pierre; Audry, Antoine; Becquemont, Laurent; Borel, Thomas; Cazeneuve, Béatrice; Courtois, Jocelyn; Detournay, Bruno; Favre, Pascal; Granger, Muriel; Josseran, Anne; Lassale, Catherine; Louvet, Olivier; Pinson, Jean; de Pouvourville, Gérard; Rochaix, Lise; Rumeau-Pichon, Catherine; de Saab, Rima; Schwarzinger, Mickaël; Sun, Aristide

    2013-01-01

    The participants in round table 6 of the Giens Workshops 2012 drafted recommendations based on the collective interpretation of important elements of the decree concerning the medico-economic evaluation of health products published a few days earlier (02 October 2012). The medico-economic evaluation (MEE), becomes an additional determinant for fixing the prices of health products by the Health products economic committee (Comité économique des produits de santé, CEPS) via the hierarchisation of treatment strategies, and thus modifies the market access conditions. Limiting the analysis to medicinal products and medical devices for which a major, important or moderate improvement in the medical service rendered (ASMR) or of the expected service (ASA) has been requested and presenting a significant budget impact on the Social Security expenses, excludes health products with ASMR or ASA with a lower level requested which often create complex price fixing problems and often have a major budget impact. This latter concept remains to be defined in detail. The MEE envisaged for the first registration must include the need to confirm or refute the initial hypotheses especially concerning the actual position in the therapeutic strategy at the time of renewal of the registration. For the first registration, the conventional reference to European prices guaranteeing a minimum price to innovative medicinal products, the medico-economic models submitted by the industry to the French Drug Authority (Haute autorité de santé, HAS) must be used to guide the compilation of new data to be requested at the time of the registration renewal and to negotiate the level of the discounts in the framework of a price-volume agreement, if applicable. The MEE will allow comparing the result of the analysis to the model hypothesis at the time of the renewal of the registration, which may contribute to the renegotiation (either up or down) of the price of health goods. The costs related to obtaining new data must be controlled. In order for the MEE to allow confirming the relationship between the price requested and the benefit expected, the group privileges the definition of reference values with an indicative and non-normative value, likely to evolve with time rather than a threshold. Concerning the evaluation procedure: the time to market access must not be lengthened; while the possibility of regular meetings between the industry and the HAS is recommended to avoid methodological divergences. A transitory period should allow the implementation of the entire evaluation procedure which must also take into account the specificities of health products registered before the 3 October 2013. © 2013 Société Française de Pharmacologie et de Thérapeutique.

  15. Can we well assess the relative efficacy and tolerability of a new drug versus others at the time of marketing authorization using mixed treatment comparisons? A detailed illustration with escitalopram.

    PubMed

    Llorca, Pierre-Michel; Lançon, Christophe; Brignone, Mélanie; Painchault, Caroline; Rive, Benoit; Toumi, Mondher; François, Clément

    2015-01-01

    To assess the variation of relative efficacy and tolerability of an antidepressant versus others based on both pre-marketing (registration studies) and post-marketing studies versus pre-marketing studies only in patients with major depressive disorder. The relative efficacy and tolerability of antidepressants was assessed by mixed treatment comparisons (MTCs) using data acquired over two time periods: before registration of the reference drug escitalopram (1989-2002) and up to 5 years later (1989-2007). Ranking probability outputs were presented for efficacy, using change from baseline to 8 weeks on Montgomery-Åsberg Depression Rating Scale total score, and tolerability, using withdrawals due to adverse events. The relative efficacy and tolerability of some selected antidepressants, including escitalopram, varied considerably over the two time periods. The improved relative efficacy and tolerability of escitalopram over time, compared with citalopram, was demonstrated by greater separation of ranking probability curves for efficacy and tolerability. In 2002, escitalopram ranked low with 13.9% and 5.1% probability of being in the top four antidepressants' relative efficacy and tolerability, respectively. In 2007, ranking probabilities for relative efficacy and tolerability of escitalopram increased to 52.5% and 82.1%, respectively. Time of marketing authorization may not be the most appropriate time to evaluate the relative efficacy and tolerability of a new antidepressant based on MTC approach due to the asymmetry of information between new and older compounds. However, the first evaluation of relative effect of a new drug for health technology assessment recommendations is commonly done at this time. Re-evaluation of a drug several years after its launch is likely to provide a more accurate indication of its relative efficacy and tolerability.

  16. SU-F-J-96: Comparison of Frame-Based and Mutual Information Registration Techniques for CT and MR Image Sets

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Popple, R; Bredel, M; Brezovich, I

    Purpose: To compare the accuracy of CT-MR registration using a mutual information method with registration using a frame-based localizer box. Methods: Ten patients having the Leksell head frame and scanned with a modality specific localizer box were imported into the treatment planning system. The fiducial rods of the localizer box were contoured on both the MR and CT scans. The skull was contoured on the CT images. The MR and CT images were registered by two methods. The frame-based method used the transformation that minimized the mean square distance of the centroids of the contours of the fiducial rods frommore » a mathematical model of the localizer. The mutual information method used automated image registration tools in the TPS and was restricted to a volume-of-interest defined by the skull contours with a 5 mm margin. For each case, the two registrations were adjusted by two evaluation teams, each comprised of an experienced radiation oncologist and neurosurgeon, to optimize alignment in the region of the brainstem. The teams were blinded to the registration method. Results: The mean adjustment was 0.4 mm (range 0 to 2 mm) and 0.2 mm (range 0 to 1 mm) for the frame and mutual information methods, respectively. The median difference between the frame and mutual information registrations was 0.3 mm, but was not statistically significant using the Wilcoxon signed rank test (p=0.37). Conclusion: The difference between frame and mutual information registration techniques was neither statistically significant nor, for most applications, clinically important. These results suggest that mutual information is equivalent to frame-based image registration for radiosurgery. Work is ongoing to add additional evaluators and to assess the differences between evaluators.« less

  17. European regulation model for herbal medicine: The assessment of the EU monograph and the safety and efficacy evaluation in marketing authorization or registration in Member States.

    PubMed

    Qu, Liping; Zou, Wenjun; Wang, YiTao; Wang, Mei

    2018-03-15

    The European Union (EU) has created a regulatory framework for herbal medicinal products (HMPs) since the enforcement of Directive 2004/24/EC. Substantial achievements have been made, with 1719 traditional use marketing registrations (TURs) and 859 well-established use marketing authorizations (WEU-MAs) for HMPs granted by the end of 2016. Apparently, the European regulation model has worked out well and in that the essential feature is the use of EU herbal monographs into those granted WEU-MAs and TURs. A systematic analysis of the European regulation model for HMPs and the EU herbal monograph's part of this model are undertaken to assist understanding of the EU legislation particularly for interested parties those from outside EU area, and afterwards, to help in decision-making in the HMPs registration in European market for pharmaceutical companies, as well as in the establishment of legislation in countries with strong traditional use of herbal remedies. A search of PubMed, ScienceDirect, the European Medicines Agency website and the Heads of Medicines Agencies website was conducted (up to December 2017), and the available information on regulation of HMPs in the EU was collected. The evaluation of applications by National Competent Authorities (NCAs) at a national level together with the assessment of EU monographs by the Committee on Herbal Medicinal Products (HMPC) at the European level constitute the European regulation framework for HMPs. As the scientific opinion about the safety and efficacy of HMPs from HMPC, the EU herbal monographs have been given a constitutional-based meaning to the TURs and WEU-MAs of HMPs and play a supportive function in the marketing procedure in Member States. The European framework has provided a powerful regulation model for harmonization of scientific assessment and facilitation of product marketing. For the pharmaceutical industries particularly those outside the EU, optimal use of the EU herbal monograph in their marketing procedure in Europe could be of great benefit. Furthermore, this model is well worth learning from for other countries and regions outside the EU to help the establishment of legislation in countries with strong traditional use of herbal remedies and contribute to the safe use of traditional herbal medicine. Copyright © 2018 Elsevier GmbH. All rights reserved.

  18. Mass preserving registration for lung CT

    NASA Astrophysics Data System (ADS)

    Gorbunova, Vladlena; Lo, Pechin; Loeve, Martine; Tiddens, Harm A.; Sporring, Jon; Nielsen, Mads; de Bruijne, Marleen

    2009-02-01

    In this paper, we evaluate a novel image registration method on a set of expiratory-inspiratory pairs of computed tomography (CT) lung scans. A free-form multi resolution image registration technique is used to match two scans of the same subject. To account for the differences in the lung intensities due to differences in inspiration level, we propose to adjust the intensity of lung tissue according to the local expansion or compression. An image registration method without intensity adjustment is compared to the proposed method. Both approaches are evaluated on a set of 10 pairs of expiration and inspiration CT scans of children with cystic fibrosis lung disease. The proposed method with mass preserving adjustment results in significantly better alignment of the vessel trees. Analysis of local volume change for regions with trapped air compared to normally ventilated regions revealed larger differences between these regions in the case of mass preserving image registration, indicating that mass preserving registration is better at capturing localized differences in lung deformation.

  19. ASP Networking Sessions Summary

    NASA Astrophysics Data System (ADS)

    Bartolone, L. M.

    2008-06-01

    In response to evaluation conducted during the Annual Meeting of the Astronomical Society of the Pacific in 2006, ``Engaging the EPO Community: Best Practices, New Approaches,'' loosely structured networking sessions were added by the program committee in an effort to assist conference attendees in achieving their stated conference goals. The co-chairs of the 2007 conference invited registrants to serve as facilitators for twelve networking sessions. This work aims to summarize the conversations that took place during those sessions, based upon notes and artifacts provided to the author by the session facilitators.

  20. Socioeconomic factors as predictors of organ donation.

    PubMed

    Shah, Malay B; Vilchez, Valery; Goble, Adam; Daily, Michael F; Berger, Jonathan C; Gedaly, Roberto; DuBay, Derek A

    2018-01-01

    Despite numerous initiatives to increase solid organs for transplant, the gap between donors and recipients widens. There is little in the literature identifying socioeconomic predictors for donation. We evaluate the correlation between socioeconomic factors and familial authorization for donation. A retrospective analysis of adult potential donor referrals between 2007 and 2012 to our organ procurement organization (OPO) was performed. Potential donor information was obtained from the OPO database, death certificates, and the US Census Report. Data on demographics, education, residence, income, registry status, cause and manner of death, as well as OPO assessments and approach for donation were collected. End point was familial authorization for donation. A total of 1059 potential donors were included, with an overall authorization rate of 47%. The majority was not on the donor registry (73%). Younger donors (18-39 y: odds ratio [OR] = 4.9, P < 0.001; 40-60 y: OR = 2.1, P < 0.001), higher levels of education (college: OR = 2.5, P = 0.005; graduate studies: OR = 3.9, P = 0.002), prior listing on the donor registry (OR = 10.3, P < 0.001), and residence in counties with lower poverty rates than the US rates (OR = 1.7, P = 0.02) were independently associated with higher authorization rates. Decoupling (OR = 3.1, P < 0.001) and donation first mentioned by the local health care provider (OR = 1.8, P = 0.01) were also independently associated with higher authorization rates. Donor registration correlated most strongly with the highest authorization rates. These results indicate that public educational efforts in populations with unfavorable socioeconomic considerations may be beneficial in improving donor registration. Collaborations with local providers as well as OPO in-hospital assessments and approach techniques can help with improving authorization rates. Copyright © 2017 Elsevier Inc. All rights reserved.

  1. Estimation of motion fields by non-linear registration for local lung motion analysis in 4D CT image data.

    PubMed

    Werner, René; Ehrhardt, Jan; Schmidt-Richberg, Alexander; Heiss, Anabell; Handels, Heinz

    2010-11-01

    Motivated by radiotherapy of lung cancer non- linear registration is applied to estimate 3D motion fields for local lung motion analysis in thoracic 4D CT images. Reliability of analysis results depends on the registration accuracy. Therefore, our study consists of two parts: optimization and evaluation of a non-linear registration scheme for motion field estimation, followed by a registration-based analysis of lung motion patterns. The study is based on 4D CT data of 17 patients. Different distance measures and force terms for thoracic CT registration are implemented and compared: sum of squared differences versus a force term related to Thirion's demons registration; masked versus unmasked force computation. The most accurate approach is applied to local lung motion analysis. Masked Thirion forces outperform the other force terms. The mean target registration error is 1.3 ± 0.2 mm, which is in the order of voxel size. Based on resulting motion fields and inter-patient normalization of inner lung coordinates and breathing depths a non-linear dependency between inner lung position and corresponding strength of motion is identified. The dependency is observed for all patients without or with only small tumors. Quantitative evaluation of the estimated motion fields indicates high spatial registration accuracy. It allows for reliable registration-based local lung motion analysis. The large amount of information encoded in the motion fields makes it possible to draw detailed conclusions, e.g., to identify the dependency of inner lung localization and motion. Our examinations illustrate the potential of registration-based motion analysis.

  2. Propagation of registration uncertainty during multi-fraction cervical cancer brachytherapy

    NASA Astrophysics Data System (ADS)

    Amir-Khalili, A.; Hamarneh, G.; Zakariaee, R.; Spadinger, I.; Abugharbieh, R.

    2017-10-01

    Multi-fraction cervical cancer brachytherapy is a form of image-guided radiotherapy that heavily relies on 3D imaging during treatment planning, delivery, and quality control. In this context, deformable image registration can increase the accuracy of dosimetric evaluations, provided that one can account for the uncertainties associated with the registration process. To enable such capability, we propose a mathematical framework that first estimates the registration uncertainty and subsequently propagates the effects of the computed uncertainties from the registration stage through to the visualizations, organ segmentations, and dosimetric evaluations. To ensure the practicality of our proposed framework in real world image-guided radiotherapy contexts, we implemented our technique via a computationally efficient and generalizable algorithm that is compatible with existing deformable image registration software. In our clinical context of fractionated cervical cancer brachytherapy, we perform a retrospective analysis on 37 patients and present evidence that our proposed methodology for computing and propagating registration uncertainties may be beneficial during therapy planning and quality control. Specifically, we quantify and visualize the influence of registration uncertainty on dosimetric analysis during the computation of the total accumulated radiation dose on the bladder wall. We further show how registration uncertainty may be leveraged into enhanced visualizations that depict the quality of the registration and highlight potential deviations from the treatment plan prior to the delivery of radiation treatment. Finally, we show that we can improve the transfer of delineated volumetric organ segmentation labels from one fraction to the next by encoding the computed registration uncertainties into the segmentation labels.

  3. 3D point cloud analysis of structured light registration in computer-assisted navigation in spinal surgeries

    NASA Astrophysics Data System (ADS)

    Gupta, Shaurya; Guha, Daipayan; Jakubovic, Raphael; Yang, Victor X. D.

    2017-02-01

    Computer-assisted navigation is used by surgeons in spine procedures to guide pedicle screws to improve placement accuracy and in some cases, to better visualize patient's underlying anatomy. Intraoperative registration is performed to establish a correlation between patient's anatomy and the pre/intra-operative image. Current algorithms rely on seeding points obtained directly from the exposed spinal surface to achieve clinically acceptable registration accuracy. Registration of these three dimensional surface point-clouds are prone to various systematic errors. The goal of this study was to evaluate the robustness of surgical navigation systems by looking at the relationship between the optical density of an acquired 3D point-cloud and the corresponding surgical navigation error. A retrospective review of a total of 48 registrations performed using an experimental structured light navigation system developed within our lab was conducted. For each registration, the number of points in the acquired point cloud was evaluated relative to whether the registration was acceptable, the corresponding system reported error and target registration error. It was demonstrated that the number of points in the point cloud neither correlates with the acceptance/rejection of a registration or the system reported error. However, a negative correlation was observed between the number of the points in the point-cloud and the corresponding sagittal angular error. Thus, system reported total registration points and accuracy are insufficient to gauge the accuracy of a navigation system and the operating surgeon must verify and validate registration based on anatomical landmarks prior to commencing surgery.

  4. [Population-based cancer registration in Germany. Essentials and perspectives].

    PubMed

    Katalinic, A

    2004-05-01

    Although cancer registration has a long tradition in Germany, wide areas remained blank spaces on the map concerning population-based cancer registration. The situation changed completely when a federal law on cancer registration (KRG, 1995-1999) took effect. Now all federal states have established population-based cancer registries on a legal basis. In spite of the uniform model of cancer registration anchored in the KRG, 16 different models have developed in Germany. Completeness of cancer registration was constantly improved over the last several years. In addition to the Saarland cancer registry, further registries can now provide a high grade of registration for all cancer sites. Essential tasks, such as public reporting and support of cancer research, can now be better fulfilled. Even taking the great developments in cancer registration in Germany into consideration, some deficits still continue to exist. These deficits are mostly caused by heterogeneity and missing compatibility of the cancer registry laws of the federal states. After the focus of cancer registration was on developing valid registries,now the focus has to be changed to the usability of cancer registry data. These data can be used e. g. for research on etiology and evaluation of programs on early cancer detection. Scientists in the field of cancer epidemiology, public health, and cancer care are invited to use data of cancer registries for research and evaluation projects intensively.

  5. An atlas-based multimodal registration method for 2D images with discrepancy structures.

    PubMed

    Lv, Wenchao; Chen, Houjin; Peng, Yahui; Li, Yanfeng; Li, Jupeng

    2018-06-04

    An atlas-based multimodal registration method for 2-dimension images with discrepancy structures was proposed in this paper. Atlas was utilized for complementing the discrepancy structure information in multimodal medical images. The scheme includes three steps: floating image to atlas registration, atlas to reference image registration, and field-based deformation. To evaluate the performance, a frame model, a brain model, and clinical images were employed in registration experiments. We measured the registration performance by the squared sum of intensity differences. Results indicate that this method is robust and performs better than the direct registration for multimodal images with discrepancy structures. We conclude that the proposed method is suitable for multimodal images with discrepancy structures. Graphical Abstract An Atlas-based multimodal registration method schematic diagram.

  6. Validation of motion correction techniques for liver CT perfusion studies

    PubMed Central

    Chandler, A; Wei, W; Anderson, E F; Herron, D H; Ye, Z; Ng, C S

    2012-01-01

    Objectives Motion in images potentially compromises the evaluation of temporally acquired CT perfusion (CTp) data; image registration should mitigate this, but first requires validation. Our objective was to compare the relative performance of manual, rigid and non-rigid registration techniques to correct anatomical misalignment in acquired liver CTp data sets. Methods 17 data sets in patients with liver tumours who had undergone a CTp protocol were evaluated. Each data set consisted of a cine acquisition during a breath-hold (Phase 1), followed by six further sets of cine scans (each containing 11 images) acquired during free breathing (Phase 2). Phase 2 images were registered to a reference image from Phase 1 cine using two semi-automated intensity-based registration techniques (rigid and non-rigid) and a manual technique (the only option available in the relevant vendor CTp software). The performance of each technique to align liver anatomy was assessed by four observers, independently and blindly, on two separate occasions, using a semi-quantitative visual validation study (employing a six-point score). The registration techniques were statistically compared using an ordinal probit regression model. Results 306 registrations (2448 observer scores) were evaluated. The three registration techniques were significantly different from each other (p=0.03). On pairwise comparison, the semi-automated techniques were significantly superior to the manual technique, with non-rigid significantly superior to rigid (p<0.0001), which in turn was significantly superior to manual registration (p=0.04). Conclusion Semi-automated registration techniques achieved superior alignment of liver anatomy compared with the manual technique. We hope this will translate into more reliable CTp analyses. PMID:22374283

  7. The influence of the image registration method on the adaptive radiotherapy. A proof of the principle in a selected case of prostate IMRT.

    PubMed

    Berenguer, Roberto; de la Vara, Victoria; Lopez-Honrubia, Veronica; Nuñez, Ana Teresa; Rivera, Miguel; Villas, Maria Victoria; Sabater, Sebastia

    2018-01-01

    To analyse the influence of the image registration method on the adaptive radiotherapy of an IMRT prostate treatment, and to compare the dose accumulation according to 3 different image registration methods with the planned dose. The IMRT prostate patient was CT imaged 3 times throughout his treatment. The prostate, PTV, rectum and bladder were segmented on each CT. A Rigid, a deformable (DIR) B-spline and a DIR with landmarks registration algorithms were employed. The difference between the accumulated doses and planned doses were evaluated by the gamma index. The Dice coefficient and Hausdorff distance was used to evaluate the overlap between volumes, to quantify the quality of the registration. When comparing adaptive vs no adaptive RT, the gamma index calculation showed large differences depending on the image registration method (as much as 87.6% in the case of DIR B-spline). The quality of the registration was evaluated using an index such as the Dice coefficient. This showed that the best result was obtained with DIR with landmarks compared with the rest and it was always above 0.77, reported as a recommended minimum value for prostate studies in a multi-centre review. Apart from showing the importance of the application of an adaptive RT protocol in a particular treatment, this work shows that the election of the registration method is decisive in the result of the adaptive radiotherapy and dose accumulation. Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  8. 12 CFR 610.101 - Authority, purpose, and scope.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 610.101 Banks and Banking FARM CREDIT ADMINISTRATION FARM CREDIT SYSTEM REGISTRATION OF MORTGAGE LOAN ORIGINATORS § 610.101 Authority, purpose, and scope. (a) Authority. This part is issued pursuant to the Secure.... This part applies to any Farm Credit System lending institution that actually originates residential...

  9. NoRMCorre: An online algorithm for piecewise rigid motion correction of calcium imaging data.

    PubMed

    Pnevmatikakis, Eftychios A; Giovannucci, Andrea

    2017-11-01

    Motion correction is a challenging pre-processing problem that arises early in the analysis pipeline of calcium imaging data sequences. The motion artifacts in two-photon microscopy recordings can be non-rigid, arising from the finite time of raster scanning and non-uniform deformations of the brain medium. We introduce an algorithm for fast Non-Rigid Motion Correction (NoRMCorre) based on template matching. NoRMCorre operates by splitting the field of view (FOV) into overlapping spatial patches along all directions. The patches are registered at a sub-pixel resolution for rigid translation against a regularly updated template. The estimated alignments are subsequently up-sampled to create a smooth motion field for each frame that can efficiently approximate non-rigid artifacts in a piecewise-rigid manner. Existing approaches either do not scale well in terms of computational performance or are targeted to non-rigid artifacts arising just from the finite speed of raster scanning, and thus cannot correct for non-rigid motion observable in datasets from a large FOV. NoRMCorre can be run in an online mode resulting in comparable to or even faster than real time motion registration of streaming data. We evaluate its performance with simple yet intuitive metrics and compare against other non-rigid registration methods on simulated data and in vivo two-photon calcium imaging datasets. Open source Matlab and Python code is also made available. The proposed method and accompanying code can be useful for solving large scale image registration problems in calcium imaging, especially in the presence of non-rigid deformations. Copyright © 2017 The Author(s). Published by Elsevier B.V. All rights reserved.

  10. Hand–eye calibration using a target registration error model

    PubMed Central

    Morgan, Isabella; Jayarathne, Uditha; Ma, Burton; Peters, Terry M.

    2017-01-01

    Surgical cameras are prevalent in modern operating theatres and are often used as a surrogate for direct vision. Visualisation techniques (e.g. image fusion) made possible by tracking the camera require accurate hand–eye calibration between the camera and the tracking system. The authors introduce the concept of ‘guided hand–eye calibration’, where calibration measurements are facilitated by a target registration error (TRE) model. They formulate hand–eye calibration as a registration problem between homologous point–line pairs. For each measurement, the position of a monochromatic ball-tip stylus (a point) and its projection onto the image (a line) is recorded, and the TRE of the resulting calibration is predicted using a TRE model. The TRE model is then used to guide the placement of the calibration tool, so that the subsequent measurement minimises the predicted TRE. Assessing TRE after each measurement produces accurate calibration using a minimal number of measurements. As a proof of principle, they evaluated guided calibration using a webcam and an endoscopic camera. Their endoscopic camera results suggest that millimetre TRE is achievable when at least 15 measurements are acquired with the tracker sensor ∼80 cm away on the laparoscope handle for a target ∼20 cm away from the camera. PMID:29184657

  11. Comparison of time-series registration methods in breast dynamic infrared imaging

    NASA Astrophysics Data System (ADS)

    Riyahi-Alam, S.; Agostini, V.; Molinari, F.; Knaflitz, M.

    2015-03-01

    Automated motion reduction in dynamic infrared imaging is on demand in clinical applications, since movement disarranges time-temperature series of each pixel, thus originating thermal artifacts that might bias the clinical decision. All previously proposed registration methods are feature based algorithms requiring manual intervention. The aim of this work is to optimize the registration strategy specifically for Breast Dynamic Infrared Imaging and to make it user-independent. We implemented and evaluated 3 different 3D time-series registration methods: 1. Linear affine, 2. Non-linear Bspline, 3. Demons applied to 12 datasets of healthy breast thermal images. The results are evaluated through normalized mutual information with average values of 0.70 ±0.03, 0.74 ±0.03 and 0.81 ±0.09 (out of 1) for Affine, Bspline and Demons registration, respectively, as well as breast boundary overlap and Jacobian determinant of the deformation field. The statistical analysis of the results showed that symmetric diffeomorphic Demons' registration method outperforms also with the best breast alignment and non-negative Jacobian values which guarantee image similarity and anatomical consistency of the transformation, due to homologous forces enforcing the pixel geometric disparities to be shortened on all the frames. We propose Demons' registration as an effective technique for time-series dynamic infrared registration, to stabilize the local temperature oscillation.

  12. [Correlation of noises in the channels of digital X-ray receiver-transformer and the evaluation of registration's quant efficiency].

    PubMed

    Porosev, V V; Shekhtman, L I; Zelikman, M I; Blinov, N N

    2004-01-01

    Theoretical and experimental research results related with the influence of correlation of signals in neighboring elements of digital X-ray receiver-transformer produced on the evaluation of the output ratio noise/signal and, as a consequence, on the evaluation of quantum registration efficiency are described in the paper.

  13. 76 FR 72404 - Pesticides: Availability of Pesticide Registration Notice Regarding the Non-Dietary Exposure Task...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-11-23

    ... Pesticide Registration Notice Regarding the Non-Dietary Exposure Task Force AGENCY: Environmental Protection... Registration Notice (PR Notice) regarding the data development efforts of the Non-Dietary Exposure Task Force... participate. FOR FURTHER INFORMATION CONTACT: Richard P. Dumas, Pesticide Re- evaluation Division (7508P...

  14. Cross contrast multi-channel image registration using image synthesis for MR brain images.

    PubMed

    Chen, Min; Carass, Aaron; Jog, Amod; Lee, Junghoon; Roy, Snehashis; Prince, Jerry L

    2017-02-01

    Multi-modal deformable registration is important for many medical image analysis tasks such as atlas alignment, image fusion, and distortion correction. Whereas a conventional method would register images with different modalities using modality independent features or information theoretic metrics such as mutual information, this paper presents a new framework that addresses the problem using a two-channel registration algorithm capable of using mono-modal similarity measures such as sum of squared differences or cross-correlation. To make it possible to use these same-modality measures, image synthesis is used to create proxy images for the opposite modality as well as intensity-normalized images from each of the two available images. The new deformable registration framework was evaluated by performing intra-subject deformation recovery, intra-subject boundary alignment, and inter-subject label transfer experiments using multi-contrast magnetic resonance brain imaging data. Three different multi-channel registration algorithms were evaluated, revealing that the framework is robust to the multi-channel deformable registration algorithm that is used. With a single exception, all results demonstrated improvements when compared against single channel registrations using the same algorithm with mutual information. Copyright © 2016 Elsevier B.V. All rights reserved.

  15. 12 CFR 998.3 - Reservation of authority.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 12 Banks and Banking 7 2010-01-01 2010-01-01 false Reservation of authority. 998.3 Section 998.3 Banks and Banking FEDERAL HOUSING FINANCE BOARD FEDERAL HOME LOAN BANK DISCLOSURES REGISTRATION OF FEDERAL HOME LOAN BANK EQUITY SECURITIES § 998.3 Reservation of authority. The requirements of this part...

  16. 75 FR 26645 - Operating Requirements: Domestic, Flag, Supplemental, Commuter, and On-Demand Operations...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-05-12

    ... aircraft, registration markings, and serial number of each aircraft authorized for use. (i) Subject to the... Administrative practice and procedure, Air carriers, Aircraft, Aviation safety, Charter flights, Reporting, and... operation using any aircraft not listed. (5) Kinds of operations authorized. (6) Authorization and...

  17. Relative added value: what are the tools to evaluate it?

    PubMed

    Le Jeunne, Claire; Woronoff-Lemsi, Marie-Christine; David, Nadine; de Sahb, Rima

    2008-01-01

    The relative added value of a drug is currently evaluated in France by the Transparency Commission (TC) of the National Health Authority (HAS), by assigning a level of Improvement in Actual Benefit (IAB). IAB is based on two parameters, efficacy and safety of the product, in a defined target population, either as compared to one or more other drugs with similar indications, or within therapeutic strategy. The items used for evaluation, including the level of clinical effect, the relevance of the comparator, the choice of comparison criteria and the methodology used (indirect comparison, non-inferiority studies, etc.), have been reviewed by the working group in Giens with regard to an analysis of the opinion on TC issued between 2004 and 2007 in several therapeutic areas First of all, this attempt at rationalisation based on the criteria used to assess the relative added value demonstrated the rareness of direct comparative data, and was followed by a discussion on the possible broadening of the evaluation criteria. The group discussed taking into account the Public Health Impact (PHI), which has now been incorporated into the assessment of Actual Benefit (AB). The group believes that PHI seems to be more related to the notion of IAB than to that of AB. Indeed, it is frequently the relative added value of a new drug that produces an impact in public health. Conversely, considering the comparative evaluation criteria of PHI, which are not systematically taken into account in IMSR (such as improvement in the health of the population, meeting a public health need or impact on the healthcare system), PHI could legitimately be included in the assessment of the relative added value of a drug. Other parameters such as compliance or impact on professional practice have been considered. Thus, the notion of relative added value, evaluated at initial registration, could be based on an expected improvement in medical service. The notion of expected medical service leads to the requirement of producing additional data in real life (post-registration studies), which would support the definitive notion of improvement in actual benefit at the time of renewed registration, while taking into account the place occupied by the drug in the therapeutic strategy.

  18. SU-E-J-90: 2D/3D Registration Using KV-MV Image Pairs for Higher Accuracy Image Guided Radiotherapy.

    PubMed

    Furtado, H; Figl, M; Stock, M; Georg, D; Birkfellner, W

    2012-06-01

    In this work, we investigate the impact of using paired portal mega-voltage (MV) and kilo-voltage (kV) images, on 2D/3D registration accuracy with the purpose of improving tumor motion tracking during radiotherapy. Tumor motion tracking is important as motion remains one of the biggest sources of uncertainty in dose application. 2D/3D registration is successfully used in online tumor motion tracking, nevertheless, one limitation of this technique is the inability to resolve movement along the imaging beam axis using only one projection image. Our evaluation consisted in comparing the accuracy of registration using different 2D image combinations: only one 2D image (1-kV), one kV and one MV image (1kV-1MV) and two kV images (2-kV). For each of the image combinations we evaluated the registration results using 250 starting points as initial displacements from the gold standard. We measured the final mean target registration error (mTRE) and the success rate for each registration. Each of the combinations was evaluated using four different merit functions. When using the MI merit function (a popular choice for this application) the RMS mTRE drops from 6.4 mm when using only one image to 2.1 mm when using image pairs. The success rate increases from 62% to 99.6%. A similar trend was observed for all four merit functions. Typically, the results are slightly better with 2-kV images than with 1kV-1MV. We evaluated the impact of using different image combinations on accuracy of 2D/3D registration for tumor motion monitoring. Our results show that using a kV-MV image pair, leads to improved results as motion can be accurately resolved in six degrees of freedom. Given the possibility to acquire these two images simultaneously, this is not only very workflow efficient but is also shown to be a good approach to improve registration accuracy. © 2012 American Association of Physicists in Medicine.

  19. Demonstration of accuracy and clinical versatility of mutual information for automatic multimodality image fusion using affine and thin-plate spline warped geometric deformations.

    PubMed

    Meyer, C R; Boes, J L; Kim, B; Bland, P H; Zasadny, K R; Kison, P V; Koral, K; Frey, K A; Wahl, R L

    1997-04-01

    This paper applies and evaluates an automatic mutual information-based registration algorithm across a broad spectrum of multimodal volume data sets. The algorithm requires little or no pre-processing, minimal user input and easily implements either affine, i.e. linear or thin-plate spline (TPS) warped registrations. We have evaluated the algorithm in phantom studies as well as in selected cases where few other algorithms could perform as well, if at all, to demonstrate the value of this new method. Pairs of multimodal gray-scale volume data sets were registered by iteratively changing registration parameters to maximize mutual information. Quantitative registration errors were assessed in registrations of a thorax phantom using PET/CT and in the National Library of Medicine's Visible Male using MRI T2-/T1-weighted acquisitions. Registrations of diverse clinical data sets were demonstrated including rotate-translate mapping of PET/MRI brain scans with significant missing data, full affine mapping of thoracic PET/CT and rotate-translate mapping of abdominal SPECT/CT. A five-point thin-plate spline (TPS) warped registration of thoracic PET/CT is also demonstrated. The registration algorithm converged in times ranging between 3.5 and 31 min for affine clinical registrations and 57 min for TPS warping. Mean error vector lengths for rotate-translate registrations were measured to be subvoxel in phantoms. More importantly the rotate-translate algorithm performs well even with missing data. The demonstrated clinical fusions are qualitatively excellent at all levels. We conclude that such automatic, rapid, robust algorithms significantly increase the likelihood that multimodality registrations will be routinely used to aid clinical diagnoses and post-therapeutic assessment in the near future.

  20. Fundamental limits of image registration performance: Effects of image noise and resolution in CT-guided interventions.

    PubMed

    Ketcha, M D; de Silva, T; Han, R; Uneri, A; Goerres, J; Jacobson, M; Vogt, S; Kleinszig, G; Siewerdsen, J H

    2017-02-11

    In image-guided procedures, image acquisition is often performed primarily for the task of geometrically registering information from another image dataset, rather than detection / visualization of a particular feature. While the ability to detect a particular feature in an image has been studied extensively with respect to image quality characteristics (noise, resolution) and is an ongoing, active area of research, comparatively little has been accomplished to relate such image quality characteristics to registration performance. To establish such a framework, we derived Cramer-Rao lower bounds (CRLB) for registration accuracy, revealing the underlying dependencies on image variance and gradient strength. The CRLB was analyzed as a function of image quality factors (in particular, dose) for various similarity metrics and compared to registration accuracy using CT images of an anthropomorphic head phantom at various simulated dose levels. Performance was evaluated in terms of root mean square error (RMSE) of the registration parameters. Analysis of the CRLB shows two primary dependencies: 1) noise variance (related to dose); and 2) sum of squared image gradients (related to spatial resolution and image content). Comparison of the measured RMSE to the CRLB showed that the best registration method, RMSE achieved the CRLB to within an efficiency factor of 0.21, and optimal estimators followed the predicted inverse proportionality between registration performance and radiation dose. Analysis of the CRLB for image registration is an important step toward understanding and evaluating an intraoperative imaging system with respect to a registration task. While the CRLB is optimistic in absolute performance, it reveals a basis for relating the performance of registration estimators as a function of noise content and may be used to guide acquisition parameter selection (e.g., dose) for purposes of intraoperative registration.

  1. TU-B-19A-01: Image Registration II: TG132-Quality Assurance for Image Registration

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brock, K; Mutic, S

    2014-06-15

    AAPM Task Group 132 was charged with a review of the current approaches and solutions for image registration in radiotherapy and to provide recommendations for quality assurance and quality control of these clinical processes. As the results of image registration are always used as the input of another process for planning or delivery, it is important for the user to understand and document the uncertainty associate with the algorithm in general and the Result of a specific registration. The recommendations of this task group, which at the time of abstract submission are currently being reviewed by the AAPM, include themore » following components. The user should understand the basic image registration techniques and methods of visualizing image fusion. The disclosure of basic components of the image registration by commercial vendors is critical in this respect. The physicists should perform end-to-end tests of imaging, registration, and planning/treatment systems if image registration is performed on a stand-alone system. A comprehensive commissioning process should be performed and documented by the physicist prior to clinical use of the system. As documentation is important to the safe implementation of this process, a request and report system should be integrated into the clinical workflow. Finally, a patient specific QA practice should be established for efficient evaluation of image registration results. The implementation of these recommendations will be described and illustrated during this educational session. Learning Objectives: Highlight the importance of understanding the image registration techniques used in their clinic. Describe the end-to-end tests needed for stand-alone registration systems. Illustrate a comprehensive commissioning program using both phantom data and clinical images. Describe a request and report system to ensure communication and documentation. Demonstrate an clinically-efficient patient QA practice for efficient evaluation of image registration.« less

  2. A 4D biomechanical lung phantom for joint segmentation/registration evaluation

    NASA Astrophysics Data System (ADS)

    Markel, Daniel; Levesque, Ives; Larkin, Joe; Léger, Pierre; El Naqa, Issam

    2016-10-01

    At present, there exists few openly available methods for evaluation of simultaneous segmentation and registration algorithms. These methods allow for a combination of both techniques to track the tumor in complex settings such as adaptive radiotherapy. We have produced a quality assurance platform for evaluating this specific subset of algorithms using a preserved porcine lung in such that it is multi-modality compatible: positron emission tomography (PET), computer tomography (CT) and magnetic resonance imaging (MRI). A computer controlled respirator was constructed to pneumatically manipulate the lungs in order to replicate human breathing traces. A registration ground truth was provided using an in-house bifurcation tracking pipeline. Segmentation ground truth was provided by synthetic multi-compartment lesions to simulate biologically active tumor, background tissue and a necrotic core. The bifurcation tracking pipeline results were compared to digital deformations and used to evaluate three registration algorithms, Diffeomorphic demons, fast-symmetric forces demons and MiMVista’s deformable registration tool. Three segmentation algorithms the Chan Vese level sets method, a Hybrid technique and the multi-valued level sets algorithm. The respirator was able to replicate three seperate breathing traces with a mean accuracy of 2-2.2%. Bifurcation tracking error was found to be sub-voxel when using human CT data for displacements up to 6.5 cm and approximately 1.5 voxel widths for displacements up to 3.5 cm for the porcine lungs. For the fast-symmetric, diffeomorphic and MiMvista registration algorithms, mean geometric errors were found to be 0.430+/- 0.001 , 0.416+/- 0.001 and 0.605+/- 0.002 voxels widths respectively using the vector field differences and 0.4+/- 0.2 , 0.4+/- 0.2 and 0.6+/- 0.2 voxel widths using the bifurcation tracking pipeline. The proposed phantom was found sufficient for accurate evaluation of registration and segmentation algorithms. The use of automatically generated anatomical landmarks proposed can eliminate the time and potential innacuracy of manual landmark selection using expert observers.

  3. In vivo spatial correlation between (18)F-BPA and (18)F-FDG uptakes in head and neck cancer.

    PubMed

    Kobayashi, Kazuma; Kurihara, Hiroaki; Watanabe, Yoshiaki; Murakami, Naoya; Inaba, Koji; Nakamura, Satoshi; Wakita, Akihisa; Okamoto, Hiroyuki; Umezawa, Rei; Takahashi, Kana; Igaki, Hiroshi; Ito, Yoshinori; Yoshimoto, Seiichi; Shigematsu, Naoyuki; Itami, Jun

    2016-09-01

    Borono-2-(18)F-fluoro-phenylalanine ((18)F-BPA) has been used to estimate the therapeutic effects of boron neutron capture therapy (BNCT), while (18)F-fluorodeoxyglucose ((18)F-FDG) is the most commonly used positron emission tomography (PET) radiopharmaceutical in a routine clinical use. The aim of the present study was to evaluate spatial correlation between (18)F-BPA and (18)F-FDG uptakes using a deformable image registration-based technique. Ten patients with head and neck cancer were recruited from January 2014 to December 2014. All patients underwent whole-body (18)F-BPA PET/computed tomography (CT) and (18)F-FDG PET/CT within a 2-week period. For each patient, (18)F-BPA PET/CT and (18)F-FDG PET/CT images were aligned based on a deformable image registration framework. The voxel-by-voxel spatial correlation of standardized uptake value (SUV) within the tumor was analyzed. Our image processing framework achieved accurate and validated registration results for each PET/CT image. In 9/10 patients, the spatial distribution of SUVs between (18)F-BPA and (18)F-FDG showed a significant, positive correlation in the tumor volume. Deformable image registration-based voxel-wise analysis demonstrated a spatial correlation between (18)F-BPA and (18)F-FDG uptakes in the head and neck cancer. A tumor sub-volume with a high (18)F-FDG uptake may predict high accumulation of (18)F-BPA. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.

  4. Technical Note: DIRART – A software suite for deformable image registration and adaptive radiotherapy research

    PubMed Central

    Yang, Deshan; Brame, Scott; El Naqa, Issam; Aditya, Apte; Wu, Yu; Murty Goddu, S.; Mutic, Sasa; Deasy, Joseph O.; Low, Daniel A.

    2011-01-01

    Purpose: Recent years have witnessed tremendous progress in image guide radiotherapy technology and a growing interest in the possibilities for adapting treatment planning and delivery over the course of treatment. One obstacle faced by the research community has been the lack of a comprehensive open-source software toolkit dedicated for adaptive radiotherapy (ART). To address this need, the authors have developed a software suite called the Deformable Image Registration and Adaptive Radiotherapy Toolkit (DIRART). Methods:DIRART is an open-source toolkit developed in MATLAB. It is designed in an object-oriented style with focus on user-friendliness, features, and flexibility. It contains four classes of DIR algorithms, including the newer inverse consistency algorithms to provide consistent displacement vector field in both directions. It also contains common ART functions, an integrated graphical user interface, a variety of visualization and image-processing features, dose metric analysis functions, and interface routines. These interface routines make DIRART a powerful complement to the Computational Environment for Radiotherapy Research (CERR) and popular image-processing toolkits such as ITK. Results: DIRART provides a set of image processing∕registration algorithms and postprocessing functions to facilitate the development and testing of DIR algorithms. It also offers a good amount of options for DIR results visualization, evaluation, and validation. Conclusions: By exchanging data with treatment planning systems via DICOM-RT files and CERR, and by bringing image registration algorithms closer to radiotherapy applications, DIRART is potentially a convenient and flexible platform that may facilitate ART and DIR research. PMID:21361176

  5. Fast interactive registration tool for reproducible multi-spectral imaging for wound healing and treatment evaluation

    NASA Astrophysics Data System (ADS)

    Noordmans, Herke J.; de Roode, Rowland; Verdaasdonk, Rudolf

    2007-02-01

    Multi-spectral images of human tissue taken in-vivo often contain image alignment problems as patients have difficulty in retaining their posture during the acquisition time of 20 seconds. Previously, it has been attempted to correct motion errors with image registration software developed for MR or CT data but these algorithms have been proven to be too slow and erroneous for practical use with multi-spectral images. A new software package has been developed which allows the user to play a decisive role in the registration process as the user can monitor the progress of the registration continuously and force it in the right direction when it starts to fail. The software efficiently exploits videocard hardware to gain speed and to provide a perfect subvoxel correspondence between registration field and display. An 8 bit graphic card was used to efficiently register and resample 12 bit images using the hardware interpolation modes present on the graphic card. To show the feasibility of this new registration process, the software was applied in clinical practice evaluating the dosimetry for psoriasis and KTP laser treatment. The microscopic differences between images of normal skin and skin exposed to UV light proved that an affine registration step including zooming and slanting is critical for a subsequent elastic match to have success. The combination of user interactive registration software with optimal addressing the potentials of PC video card hardware greatly improves the speed of multi spectral image registration.

  6. 4D co-registration of X-ray and MR-mammograms: initial clinical results and potential incremental diagnostic value.

    PubMed

    Dietzel, Matthias; Hopp, Torsten; Ruiter, Nicole V; Kaiser, Clemens G; Kaiser, Werner A; Baltzer, Pascal A

    2015-01-01

    4D co-registration of X-ray- and MR-mammograms (XM and MM) is a new method of image fusion. The present study aims to evaluate its clinical feasibility, radiological accuracy, and potential clinical value. XM and MM of 25 patients were co-registered. Results were evaluated by a blinded reader. Precision of the 4D co-registration was "very good" (mean-score [ms]=7), and lesions were "easier to delineate" (ms=5). In 88.8%, "relevant additional diagnostic information" was present, accounting for a more "confident diagnosis" in 76% (ms=5). 4D co-registration is feasible, accurate, and of potential clinical value. Copyright © 2015 Elsevier Inc. All rights reserved.

  7. Hematology journals do not sufficiently adhere to reporting guidelines: a systematic review.

    PubMed

    Wayant, C; Smith, C; Sims, M; Vassar, M

    2017-04-01

    Essentials Reporting guidelines and trial/review registration aim to limit bias in research. We systematically reviewed hematology journals to examine the use of these policies. Forty-eight percent of journals made no use of these policies. Improving the use of reporting guidelines will improve research for all stakeholders. Background Reporting guidelines and trial/review registration policies have been instituted in order to minimize bias and improve research practices. Objective The objective of this study was to investigate the policies of hematology journals concerning reporting guideline adoption and trial/review registration. Methods We performed a web-based data abstraction from the Instructions for Authors of 67 hematology journals catalogued in the Expanded Science Citation Index of the 2014 Journal Citation Reports to identify whether each journal required, recommended or made no mention of the following reporting guidelines: EQUATOR, ICMJE, CONSORT, MOOSE, QUOROM, PRISMA, STARD, STROBE, ARRIVE and CARE. We also extracted whether journals required or recommended trial or systematic review registration. We e-mailed editors three times to determine which types of studies their journal accepts. Results Forty-eight per cent (32/67) of hematology journals do not adhere to any reporting guidelines. For responding journals, the QUOROM statement, MOOSE, CARE and PROSPERO were the least often mentioned, whereas the ICMJE guidelines, CONSORT statement and general trial registration were most often mentioned. Discussion Reporting guidelines are infrequently required or recommended by hematology journals. Furthermore, few require clinical trial or systematic review database registration. A higher rate of adherence to reporting guidelines can prevent bias from entering the literature. Participation from all stakeholders, including authors and journal editors, to improve reporting guideline and policy practices is required. © 2017 International Society on Thrombosis and Haemostasis.

  8. Registration of clinical volumes to beams-eye-view images for real-time tracking

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bryant, Jonathan H.; Rottmann, Joerg; Lewis, John H.

    2014-12-15

    Purpose: The authors combine the registration of 2D beam’s eye view (BEV) images and 3D planning computed tomography (CT) images, with relative, markerless tumor tracking to provide automatic absolute tracking of physician defined volumes such as the gross tumor volume (GTV). Methods: During treatment of lung SBRT cases, BEV images were continuously acquired with an electronic portal imaging device (EPID) operating in cine mode. For absolute registration of physician-defined volumes, an intensity based 2D/3D registration to the planning CT was performed using the end-of-exhale (EoE) phase of the four dimensional computed tomography (4DCT). The volume was converted from Hounsfield unitsmore » into electron density by a calibration curve and digitally reconstructed radiographs (DRRs) were generated for each beam geometry. Using normalized cross correlation between the DRR and an EoE BEV image, the best in-plane rigid transformation was found. The transformation was applied to physician-defined contours in the planning CT, mapping them into the EPID image domain. A robust multiregion method of relative markerless lung tumor tracking quantified deviations from the EoE position. Results: The success of 2D/3D registration was demonstrated at the EoE breathing phase. By registering at this phase and then employing a separate technique for relative tracking, the authors are able to successfully track target volumes in the BEV images throughout the entire treatment delivery. Conclusions: Through the combination of EPID/4DCT registration and relative tracking, a necessary step toward the clinical implementation of BEV tracking has been completed. The knowledge of tumor volumes relative to the treatment field is important for future applications like real-time motion management, adaptive radiotherapy, and delivered dose calculations.« less

  9. Automatic bone detection and soft tissue aware ultrasound-CT registration for computer-aided orthopedic surgery.

    PubMed

    Wein, Wolfgang; Karamalis, Athanasios; Baumgartner, Adrian; Navab, Nassir

    2015-06-01

    The transfer of preoperative CT data into the tracking system coordinates within an operating room is of high interest for computer-aided orthopedic surgery. In this work, we introduce a solution for intra-operative ultrasound-CT registration of bones. We have developed methods for fully automatic real-time bone detection in ultrasound images and global automatic registration to CT. The bone detection algorithm uses a novel bone-specific feature descriptor and was thoroughly evaluated on both in-vivo and ex-vivo data. A global optimization strategy aligns the bone surface, followed by a soft tissue aware intensity-based registration to provide higher local registration accuracy. We evaluated the system on femur, tibia and fibula anatomy in a cadaver study with human legs, where magnetically tracked bone markers were implanted to yield ground truth information. An overall median system error of 3.7 mm was achieved on 11 datasets. Global and fully automatic registration of bones aquired with ultrasound to CT is feasible, with bone detection and tracking operating in real time for immediate feedback to the surgeon.

  10. Landsat image registration for agricultural applications

    NASA Technical Reports Server (NTRS)

    Wolfe, R. H., Jr.; Juday, R. D.; Wacker, A. G.; Kaneko, T.

    1982-01-01

    An image registration system has been developed at the NASA Johnson Space Center (JSC) to spatially align multi-temporal Landsat acquisitions for use in agriculture and forestry research. Working in conjunction with the Master Data Processor (MDP) at the Goddard Space Flight Center, it functionally replaces the long-standing LACIE Registration Processor as JSC's data supplier. The system represents an expansion of the techniques developed for the MDP and LACIE Registration Processor, and it utilizes the experience gained in an IBM/JSC effort evaluating the performance of the latter. These techniques are discussed in detail. Several tests were developed to evaluate the registration performance of the system. The results indicate that 1/15-pixel accuracy (about 4m for Landsat MSS) is achievable in ideal circumstances, sub-pixel accuracy (often to 0.2 pixel or better) was attained on a representative set of U.S. acquisitions, and a success rate commensurate with the LACIE Registration Processor was realized. The system has been employed in a production mode on U.S. and foreign data, and a performance similar to the earlier tests has been noted.

  11. 76 FR 37822 - General Meeting Registration and Evaluation

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-06-28

    ...), National Protection and Programs Directorate (NPPD, Office of Cybersecurity and Communications (CS&C... Cybersecurity and Communications, Office of Emergency Communications. Title: General Meeting Registration and...

  12. Improving oncoplastic breast tumor bed localization for radiotherapy planning using image registration algorithms

    NASA Astrophysics Data System (ADS)

    Wodzinski, Marek; Skalski, Andrzej; Ciepiela, Izabela; Kuszewski, Tomasz; Kedzierawski, Piotr; Gajda, Janusz

    2018-02-01

    Knowledge about tumor bed localization and its shape analysis is a crucial factor for preventing irradiation of healthy tissues during supportive radiotherapy and as a result, cancer recurrence. The localization process is especially hard for tumors placed nearby soft tissues, which undergo complex, nonrigid deformations. Among them, breast cancer can be considered as the most representative example. A natural approach to improving tumor bed localization is the use of image registration algorithms. However, this involves two unusual aspects which are not common in typical medical image registration: the real deformation field is discontinuous, and there is no direct correspondence between the cancer and its bed in the source and the target 3D images respectively. The tumor no longer exists during radiotherapy planning. Therefore, a traditional evaluation approach based on known, smooth deformations and target registration error are not directly applicable. In this work, we propose alternative artificial deformations which model the tumor bed creation process. We perform a comprehensive evaluation of the most commonly used deformable registration algorithms: B-Splines free form deformations (B-Splines FFD), different variants of the Demons and TV-L1 optical flow. The evaluation procedure includes quantitative assessment of the dedicated artificial deformations, target registration error calculation, 3D contour propagation and medical experts visual judgment. The results demonstrate that the currently, practically applied image registration (rigid registration and B-Splines FFD) are not able to correctly reconstruct discontinuous deformation fields. We show that the symmetric Demons provide the most accurate soft tissues alignment in terms of the ability to reconstruct the deformation field, target registration error and relative tumor volume change, while B-Splines FFD and TV-L1 optical flow are not an appropriate choice for the breast tumor bed localization problem, even though the visual alignment seems to be better than for the Demons algorithm. However, no algorithm could recover the deformation field with sufficient accuracy in terms of vector length and rotation angle differences.

  13. Victoria's review of registration for health practitioners.

    PubMed

    Scotts, H; Carter, M

    1988-01-01

    This article discusses some of the issues raised in the Interim Report of the current Review of Registration of Health Practitioners being conducted for the Victorian Health Department. The Report attempts to develop the framework in which the registration Boards will operate as part of a cohesive registration system. It proposed a mechanism and criteria for the registration of new groups as well as principles which can be applied to the ongoing review of each existing Board. The Review takes the perspective that registration of health practitioners carries with it both advantages and disadvantages for the general community. Under the proposed new system the controls exercised over health care providers by Registration Boards would be evaluated on the basis of to what extent the benefits to the public outweighed the potential costs. It is in this context that the Report addresses issues such as consumer complaints handling, registration of individual practitioners and controls over professional advertising and other business practices.

  14. Data Requirements for Pesticide Registration

    EPA Pesticide Factsheets

    In evaluating a pesticide registration application, we assess a wide variety of potential human health and environmental effects associated with use of the product. Learn about these data requirements.

  15. 31 CFR 321.7 - Authorized cash payments.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 31 Money and Finance: Treasury 2 2010-07-01 2010-07-01 false Authorized cash payments. 321.7 Section 321.7 Money and Finance: Treasury Regulations Relating to Money and Finance (Continued) FISCAL... registration on the front of the security, or by a person authorized or empowered to act for a corporate legal...

  16. 76 FR 14677 - General Meeting Registration and Evaluation

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-03-17

    ... (capital/startup): $0. Total Burden Cost (operating/maintaining): $20,757. Post-Meeting/Workshop/Training..., including conferences, meetings, workshops, etc. The general registration form, general pre-meeting form...

  17. Respiratory motion correction in dynamic MRI using robust data decomposition registration - application to DCE-MRI.

    PubMed

    Hamy, Valentin; Dikaios, Nikolaos; Punwani, Shonit; Melbourne, Andrew; Latifoltojar, Arash; Makanyanga, Jesica; Chouhan, Manil; Helbren, Emma; Menys, Alex; Taylor, Stuart; Atkinson, David

    2014-02-01

    Motion correction in Dynamic Contrast Enhanced (DCE-) MRI is challenging because rapid intensity changes can compromise common (intensity based) registration algorithms. In this study we introduce a novel registration technique based on robust principal component analysis (RPCA) to decompose a given time-series into a low rank and a sparse component. This allows robust separation of motion components that can be registered, from intensity variations that are left unchanged. This Robust Data Decomposition Registration (RDDR) is demonstrated on both simulated and a wide range of clinical data. Robustness to different types of motion and breathing choices during acquisition is demonstrated for a variety of imaged organs including liver, small bowel and prostate. The analysis of clinically relevant regions of interest showed both a decrease of error (15-62% reduction following registration) in tissue time-intensity curves and improved areas under the curve (AUC60) at early enhancement. Copyright © 2013 The Authors. Published by Elsevier B.V. All rights reserved.

  18. Registration verification of SEA/AR fields. [Oregon, Texas, Montana, Nebraska, Washington, Colorado, Kansas, Oklahoma, and North Dakota

    NASA Technical Reports Server (NTRS)

    Austin, W. W.; Lautenschlager, L. (Principal Investigator)

    1981-01-01

    A method of field registration verification for 20 SEA/AR sites for the 1979 crop year is evaluated. Field delineations for the sites were entered into the data base, and their registration verified using single channel gray scale computer printout maps of LANDSAT data taken over the site.

  19. Lung motion estimation using dynamic point shifting: An innovative model based on a robust point matching algorithm.

    PubMed

    Yi, Jianbing; Yang, Xuan; Chen, Guoliang; Li, Yan-Ran

    2015-10-01

    Image-guided radiotherapy is an advanced 4D radiotherapy technique that has been developed in recent years. However, respiratory motion causes significant uncertainties in image-guided radiotherapy procedures. To address these issues, an innovative lung motion estimation model based on a robust point matching is proposed in this paper. An innovative robust point matching algorithm using dynamic point shifting is proposed to estimate patient-specific lung motion during free breathing from 4D computed tomography data. The correspondence of the landmark points is determined from the Euclidean distance between the landmark points and the similarity between the local images that are centered at points at the same time. To ensure that the points in the source image correspond to the points in the target image during other phases, the virtual target points are first created and shifted based on the similarity between the local image centered at the source point and the local image centered at the virtual target point. Second, the target points are shifted by the constrained inverse function mapping the target points to the virtual target points. The source point set and shifted target point set are used to estimate the transformation function between the source image and target image. The performances of the authors' method are evaluated on two publicly available DIR-lab and POPI-model lung datasets. For computing target registration errors on 750 landmark points in six phases of the DIR-lab dataset and 37 landmark points in ten phases of the POPI-model dataset, the mean and standard deviation by the authors' method are 1.11 and 1.11 mm, but they are 2.33 and 2.32 mm without considering image intensity, and 1.17 and 1.19 mm with sliding conditions. For the two phases of maximum inhalation and maximum exhalation in the DIR-lab dataset with 300 landmark points of each case, the mean and standard deviation of target registration errors on the 3000 landmark points of ten cases by the authors' method are 1.21 and 1.04 mm. In the EMPIRE10 lung registration challenge, the authors' method ranks 24 of 39. According to the index of the maximum shear stretch, the authors' method is also efficient to describe the discontinuous motion at the lung boundaries. By establishing the correspondence of the landmark points in the source phase and the other target phases combining shape matching and image intensity matching together, the mismatching issue in the robust point matching algorithm is adequately addressed. The target registration errors are statistically reduced by shifting the virtual target points and target points. The authors' method with consideration of sliding conditions can effectively estimate the discontinuous motion, and the estimated motion is natural. The primary limitation of the proposed method is that the temporal constraints of the trajectories of voxels are not introduced into the motion model. However, the proposed method provides satisfactory motion information, which results in precise tumor coverage by the radiation dose during radiotherapy.

  20. Administration: Attendance of Military and Civilian Personnel at Private Organization Meetings

    DTIC Science & Technology

    1983-12-01

    actual costs incurred by the sponsor of the meeting. b. Attendee and traveler should be aware that there are reimburs - able and nonreimbursable...registration fees and that all registration and admittance fees may not be reimbursable . Reimbursement for such fees will be determined by the orders...or substantial be authorized attendance in a permissive TDY status without payment of travel expenses, per diem, or other reimbursable entitlements

  1. Accurate CT-MR image registration for deep brain stimulation: a multi-observer evaluation study

    NASA Astrophysics Data System (ADS)

    Rühaak, Jan; Derksen, Alexander; Heldmann, Stefan; Hallmann, Marc; Meine, Hans

    2015-03-01

    Since the first clinical interventions in the late 1980s, Deep Brain Stimulation (DBS) of the subthalamic nucleus has evolved into a very effective treatment option for patients with severe Parkinson's disease. DBS entails the implantation of an electrode that performs high frequency stimulations to a target area deep inside the brain. A very accurate placement of the electrode is a prerequisite for positive therapy outcome. The assessment of the intervention result is of central importance in DBS treatment and involves the registration of pre- and postinterventional scans. In this paper, we present an image processing pipeline for highly accurate registration of postoperative CT to preoperative MR. Our method consists of two steps: a fully automatic pre-alignment using a detection of the skull tip in the CT based on fuzzy connectedness, and an intensity-based rigid registration. The registration uses the Normalized Gradient Fields distance measure in a multilevel Gauss-Newton optimization framework and focuses on a region around the subthalamic nucleus in the MR. The accuracy of our method was extensively evaluated on 20 DBS datasets from clinical routine and compared with manual expert registrations. For each dataset, three independent registrations were available, thus allowing to relate algorithmic with expert performance. Our method achieved an average registration error of 0.95mm in the target region around the subthalamic nucleus as compared to an inter-observer variability of 1.12 mm. Together with the short registration time of about five seconds on average, our method forms a very attractive package that can be considered ready for clinical use.

  2. Pain education in pre-registration professional health courses: a protocol for a scoping review.

    PubMed

    Thompson, Kate; Milligan, James; Johnson, Mark I; Briggs, Michelle

    2016-07-18

    Pain is a global health concern causing significant health and social problems with evidence that patients experiencing pain are receiving inadequate care. The content of pain education in pre-registration professional health courses is thought to be lacking both in the UK and internationally which is unacceptable considering the prevalence of pain. Evaluating the effect of education is complex in that the outcome (improved healthcare) is some distance from the educational approach. Best evidence medical education has been proposed as a continuum between 'opinion-based teaching' and 'evidence-based teaching'. Searching for evidence to inform best practice in health education is complex. A scoping review provides a practical and comprehensive strategy to locate and synthesise literature of varied methodology including reports from a variety of sources. The aim of this article is to describe a protocol for a scoping review that will locate, map and report research, guidelines and policies for pain education in pre-registration professional health courses. The extent, range and nature of reports will be examined, and where possible titles for potential systematic review will be identified. Reports will be included for review that are directly relevant to the development of the pain curriculum in pre-registration professional health courses, eg nursing, medicine, physiotherapy. The search strategy will identify reports that include [pain] AND [pre-registration education or curriculum] AND [health professionals] in the title or abstract. Two authors will independently screen retrieved studies against eligibility criteria. A numerical analysis regarding the extent, nature and distribution of reports will be given along with a narrative synthesis to describe characteristics of relevant reports. Formal ethical approval was not required to undertake this scoping review. Findings will be published in scientific peer-reviewed journals and via conference presentations. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  3. Registration of Laser Scanning Point Clouds: A Review.

    PubMed

    Cheng, Liang; Chen, Song; Liu, Xiaoqiang; Xu, Hao; Wu, Yang; Li, Manchun; Chen, Yanming

    2018-05-21

    The integration of multi-platform, multi-angle, and multi-temporal LiDAR data has become important for geospatial data applications. This paper presents a comprehensive review of LiDAR data registration in the fields of photogrammetry and remote sensing. At present, a coarse-to-fine registration strategy is commonly used for LiDAR point clouds registration. The coarse registration method is first used to achieve a good initial position, based on which registration is then refined utilizing the fine registration method. According to the coarse-to-fine framework, this paper reviews current registration methods and their methodologies, and identifies important differences between them. The lack of standard data and unified evaluation systems is identified as a factor limiting objective comparison of different methods. The paper also describes the most commonly-used point cloud registration error analysis methods. Finally, avenues for future work on LiDAR data registration in terms of applications, data, and technology are discussed. In particular, there is a need to address registration of multi-angle and multi-scale data from various newly available types of LiDAR hardware, which will play an important role in diverse applications such as forest resource surveys, urban energy use, cultural heritage protection, and unmanned vehicles.

  4. Registration of Laser Scanning Point Clouds: A Review

    PubMed Central

    Cheng, Liang; Chen, Song; Xu, Hao; Wu, Yang; Li, Manchun

    2018-01-01

    The integration of multi-platform, multi-angle, and multi-temporal LiDAR data has become important for geospatial data applications. This paper presents a comprehensive review of LiDAR data registration in the fields of photogrammetry and remote sensing. At present, a coarse-to-fine registration strategy is commonly used for LiDAR point clouds registration. The coarse registration method is first used to achieve a good initial position, based on which registration is then refined utilizing the fine registration method. According to the coarse-to-fine framework, this paper reviews current registration methods and their methodologies, and identifies important differences between them. The lack of standard data and unified evaluation systems is identified as a factor limiting objective comparison of different methods. The paper also describes the most commonly-used point cloud registration error analysis methods. Finally, avenues for future work on LiDAR data registration in terms of applications, data, and technology are discussed. In particular, there is a need to address registration of multi-angle and multi-scale data from various newly available types of LiDAR hardware, which will play an important role in diverse applications such as forest resource surveys, urban energy use, cultural heritage protection, and unmanned vehicles. PMID:29883397

  5. 2D-3D registration for cranial radiation therapy using a 3D kV CBCT and a single limited field-of-view 2D kV radiograph.

    PubMed

    Munbodh, Reshma; Knisely, Jonathan Ps; Jaffray, David A; Moseley, Douglas J

    2018-05-01

    We present and evaluate a fully automated 2D-3D intensity-based registration framework using a single limited field-of-view (FOV) 2D kV radiograph and a 3D kV CBCT for 3D estimation of patient setup errors during brain radiotherapy. We evaluated two similarity measures, the Pearson correlation coefficient on image intensity values (ICC) and maximum likelihood measure with Gaussian noise (MLG), derived from the statistics of transmission images. Pose determination experiments were conducted on 2D kV radiographs in the anterior-posterior (AP) and left lateral (LL) views and 3D kV CBCTs of an anthropomorphic head phantom. In order to minimize radiation exposure and exclude nonrigid structures from the registration, limited FOV 2D kV radiographs were employed. A spatial frequency band useful for the 2D-3D registration was identified from the bone-to-no-bone spectral ratio (BNBSR) of digitally reconstructed radiographs (DRRs) computed from the 3D kV planning CT of the phantom. The images being registered were filtered accordingly prior to computation of the similarity measures. We evaluated the registration accuracy achievable with a single 2D kV radiograph and with the registration results from the AP and LL views combined. We also compared the performance of the 2D-3D registration solutions proposed to that of a commercial 3D-3D registration algorithm, which used the entire skull for the registration. The ground truth was determined from markers affixed to the phantom and visible in the CBCT images. The accuracy of the 2D-3D registration solutions, as quantified by the root mean squared value of the target registration error (TRE) calculated over a radius of 3 cm for all poses tested, was ICC AP : 0.56 mm, MLG AP : 0.74 mm, ICC LL : 0.57 mm, MLG LL : 0.54 mm, ICC (AP and LL combined): 0.19 mm, and MLG (AP and LL combined): 0.21 mm. The accuracy of the 3D-3D registration algorithm was 0.27 mm. There was no significant difference in mean TRE for the 2D-3D registration algorithms using a single 2D kV radiograph with similarity measure and image view point. There was no significant difference in mean TRE between ICC LL , MLG LL , ICC (AP and LL combined), MLG (AP and LL combined), and the 3D-3D registration algorithm despite the smaller FOV used for the 2D-3D registration. While submillimeter registration accuracy was obtained with both ICC and MLG using a single 2D kV radiograph, combining the results from the two projection views resulted in a significantly smaller (P≤0.05) mean TRE. Our results indicate that it is possible to achieve submillimeter registration accuracy with both ICC and MLG using either single or dual limited FOV 2D kV radiographs of the head in the AP and LL views. The registration accuracy suggests that the 2D-3D registration solutions presented are suitable for the estimation of patient setup errors not only during conventional brain radiation therapy, but also during stereotactic procedures and proton radiation therapy where tighter setup margins are required. © 2018 American Association of Physicists in Medicine.

  6. Self-correcting multi-atlas segmentation

    NASA Astrophysics Data System (ADS)

    Gao, Yi; Wilford, Andrew; Guo, Liang

    2016-03-01

    In multi-atlas segmentation, one typically registers several atlases to the new image, and their respective segmented label images are transformed and fused to form the final segmentation. After each registration, the quality of the registration is reflected by the single global value: the final registration cost. Ideally, if the quality of the registration can be evaluated at each point, independent of the registration process, which also provides a direction in which the deformation can further be improved, the overall segmentation performance can be improved. We propose such a self-correcting multi-atlas segmentation method. The method is applied on hippocampus segmentation from brain images and statistically significantly improvement is observed.

  7. A concept for holistic whole body MRI data analysis, Imiomics

    PubMed Central

    Malmberg, Filip; Johansson, Lars; Lind, Lars; Sundbom, Magnus; Ahlström, Håkan; Kullberg, Joel

    2017-01-01

    Purpose To present and evaluate a whole-body image analysis concept, Imiomics (imaging–omics) and an image registration method that enables Imiomics analyses by deforming all image data to a common coordinate system, so that the information in each voxel can be compared between persons or within a person over time and integrated with non-imaging data. Methods The presented image registration method utilizes relative elasticity constraints of different tissue obtained from whole-body water-fat MRI. The registration method is evaluated by inverse consistency and Dice coefficients and the Imiomics concept is evaluated by example analyses of importance for metabolic research using non-imaging parameters where we know what to expect. The example analyses include whole body imaging atlas creation, anomaly detection, and cross-sectional and longitudinal analysis. Results The image registration method evaluation on 128 subjects shows low inverse consistency errors and high Dice coefficients. Also, the statistical atlas with fat content intensity values shows low standard deviation values, indicating successful deformations to the common coordinate system. The example analyses show expected associations and correlations which agree with explicit measurements, and thereby illustrate the usefulness of the proposed Imiomics concept. Conclusions The registration method is well-suited for Imiomics analyses, which enable analyses of relationships to non-imaging data, e.g. clinical data, in new types of holistic targeted and untargeted big-data analysis. PMID:28241015

  8. Termite testing continues

    Treesearch

    Terence L. Wagner; Joe Mulrooney; Chris Petereson

    2002-01-01

    The United States Department of Agriculture Forest Service's termiticide testing program provides unbiased efficacy data for product registration using standardized tests, sites and evaluation procedures. Virtually all termiticides undergo Forest Service tests prior to registration.

  9. Promoting deceased organ and tissue donation registration in family physician waiting rooms (RegisterNow-1 trial): study protocol for a pragmatic, stepped-wedge, cluster randomized controlled registry.

    PubMed

    Li, Alvin H; Garg, Amit X; Prakash, Versha; Grimshaw, Jeremy M; Taljaard, Monica; Mitchell, Joanna; Matti, Danny; Linklater, Stefanie; Naylor, Kyla L; Dixon, Stephanie; Faulds, Cathy; Bevan, Rachel; Getchell, Leah; Knoll, Greg; Kim, S Joseph; Sontrop, Jessica; Bjerre, Lise M; Tong, Allison; Presseau, Justin

    2017-12-21

    There is a worldwide shortage of organs available for transplant, leading to preventable mortality associated with end-stage organ disease. While most citizens in many countries with an intent-to-donate "opt-in" system support organ donation, registration rates remain low. In Canada, most Canadians support organ donation but less than 25% in most provinces have registered their desire to donate their organs when they die. The family physician office is a promising yet underused setting in which to promote organ donor registration and address known barriers and enablers to registering for deceased organ and tissue donation. We developed a protocol to evaluate an intervention to promote registration for organ and tissue donation in family physician waiting rooms. This protocol describes a planned, stepped-wedge, cluster randomized registry trial in six family physician offices in Ontario, Canada to evaluate the effectiveness of reception staff providing patients with a pamphlet that addresses barriers and enablers to registration including a description of how to register for organ donation. An Internet-enabled tablet will also be provided in waiting rooms so that interested patients can register while waiting for their appointments. Family physicians and reception staff will be provided with training and/or materials to support any conversations about organ donation with their patients. Following a 2-week control period, the six offices will cross sequentially into the intervention arm in randomized sequence at 2-week intervals until all offices deliver the intervention. The primary outcome will be the proportion of patients visiting the office who are registered organ donors 7 days following their office visit. We will evaluate this outcome using routinely collected registry data from provincial administrative databases. A post-trial qualitative evaluation process will assess the experiences of reception staff and family physicians with the intervention and the stepped-wedge trial design. Promoting registration for organ donation in family physician offices is a potentially useful strategy for increasing registration for organ donation. Increased registration may ultimately help to increase the number of organs available for transplant. The results of this trial will provide important preliminary data on the effectiveness of using family physician offices to promote registration for organ donation. ClinicalTrials.gov, ID: NCT03213171 . Registered on 11 July 2017.

  10. Quality assessment and improvement of nationwide cancer registration system in Taiwan: a review.

    PubMed

    Chiang, Chun-Ju; You, San-Lin; Chen, Chien-Jen; Yang, Ya-Wen; Lo, Wei-Cheng; Lai, Mei-Shu

    2015-03-01

    Cancer registration provides core information for cancer surveillance and control. The population-based Taiwan Cancer Registry was implemented in 1979. After the Cancer Control Act was promulgated in 2003, the completeness (97%) and data quality of cancer registry database has achieved at an excellent level. Hospitals with 50 or more beds, which provide outpatient and hospitalized cancer care, are recruited to report 20 items of information on all newly diagnosed cancers to the central registry office (called short-form database). The Taiwan Cancer Registry is organized and funded by the Ministry of Health and Welfare. The National Taiwan University has been contracted to operate the registry and organized an advisory board to standardize definitions of terminology, coding and procedures of the registry's reporting system since 1996. To monitor the cancer care patterns and evaluate the cancer treatment outcomes, central cancer registry has been reformed since 2002 to include detail items of the stage at diagnosis and the first course of treatment (called long-form database). There are 80 hospitals, which count for >90% of total cancer cases, involved in the long-form registration. The Taiwan Cancer Registry has run smoothly for >30 years, which provides essential foundation for academic research and cancer control policy in Taiwan. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  11. Automatic Intensity-based 3D-to-2D Registration of CT Volume and Dual-energy Digital Radiography for the Detection of Cardiac Calcification

    PubMed Central

    Chen, Xiang; Gilkeson, Robert; Fei, Baowei

    2013-01-01

    We are investigating three-dimensional (3D) to two-dimensional (2D) registration methods for computed tomography (CT) and dual-energy digital radiography (DR) for the detection of coronary artery calcification. CT is an established tool for the diagnosis of coronary artery diseases (CADs). Dual-energy digital radiography could be a cost-effective alternative for screening coronary artery calcification. In order to utilize CT as the “gold standard” to evaluate the ability of DR images for the detection and localization of calcium, we developed an automatic intensity-based 3D-to-2D registration method for 3D CT volumes and 2D DR images. To generate digital rendering radiographs (DRR) from the CT volumes, we developed three projection methods, i.e. Gaussian-weighted projection, threshold-based projection, and average-based projection. We tested normalized cross correlation (NCC) and normalized mutual information (NMI) as similarity measurement. We used the Downhill Simplex method as the search strategy. Simulated projection images from CT were fused with the corresponding DR images to evaluate the localization of cardiac calcification. The registration method was evaluated by digital phantoms, physical phantoms, and clinical data sets. The results from the digital phantoms show that the success rate is 100% with mean errors of less 0.8 mm and 0.2 degree for both NCC and NMI. The registration accuracy of the physical phantoms is 0.34 ± 0.27 mm. Color overlay and 3D visualization of the clinical data show that the two images are registered well. This is consistent with the improvement of the NMI values from 0.20 ± 0.03 to 0.25 ± 0.03 after registration. The automatic 3D-to-2D registration method is accurate and robust and may provide a useful tool to evaluate the dual-energy DR images for the detection of coronary artery calcification. PMID:24386527

  12. Automatic Intensity-based 3D-to-2D Registration of CT Volume and Dual-energy Digital Radiography for the Detection of Cardiac Calcification.

    PubMed

    Chen, Xiang; Gilkeson, Robert; Fei, Baowei

    2007-03-03

    We are investigating three-dimensional (3D) to two-dimensional (2D) registration methods for computed tomography (CT) and dual-energy digital radiography (DR) for the detection of coronary artery calcification. CT is an established tool for the diagnosis of coronary artery diseases (CADs). Dual-energy digital radiography could be a cost-effective alternative for screening coronary artery calcification. In order to utilize CT as the "gold standard" to evaluate the ability of DR images for the detection and localization of calcium, we developed an automatic intensity-based 3D-to-2D registration method for 3D CT volumes and 2D DR images. To generate digital rendering radiographs (DRR) from the CT volumes, we developed three projection methods, i.e. Gaussian-weighted projection, threshold-based projection, and average-based projection. We tested normalized cross correlation (NCC) and normalized mutual information (NMI) as similarity measurement. We used the Downhill Simplex method as the search strategy. Simulated projection images from CT were fused with the corresponding DR images to evaluate the localization of cardiac calcification. The registration method was evaluated by digital phantoms, physical phantoms, and clinical data sets. The results from the digital phantoms show that the success rate is 100% with mean errors of less 0.8 mm and 0.2 degree for both NCC and NMI. The registration accuracy of the physical phantoms is 0.34 ± 0.27 mm. Color overlay and 3D visualization of the clinical data show that the two images are registered well. This is consistent with the improvement of the NMI values from 0.20 ± 0.03 to 0.25 ± 0.03 after registration. The automatic 3D-to-2D registration method is accurate and robust and may provide a useful tool to evaluate the dual-energy DR images for the detection of coronary artery calcification.

  13. Evaluation of 14 nonlinear deformation algorithms applied to human brain MRI registration

    PubMed Central

    Klein, Arno; Andersson, Jesper; Ardekani, Babak A.; Ashburner, John; Avants, Brian; Chiang, Ming-Chang; Christensen, Gary E.; Collins, D. Louis; Gee, James; Hellier, Pierre; Song, Joo Hyun; Jenkinson, Mark; Lepage, Claude; Rueckert, Daniel; Thompson, Paul; Vercauteren, Tom; Woods, Roger P.; Mann, J. John; Parsey, Ramin V.

    2009-01-01

    All fields of neuroscience that employ brain imaging need to communicate their results with reference to anatomical regions. In particular, comparative morphometry and group analysis of functional and physiological data require coregistration of brains to establish correspondences across brain structures. It is well established that linear registration of one brain to another is inadequate for aligning brain structures, so numerous algorithms have emerged to nonlinearly register brains to one another. This study is the largest evaluation of nonlinear deformation algorithms applied to brain image registration ever conducted. Fourteen algorithms from laboratories around the world are evaluated using 8 different error measures. More than 45,000 registrations between 80 manually labeled brains were performed by algorithms including: AIR, ANIMAL, ART, Diffeomorphic Demons, FNIRT, IRTK, JRD-fluid, ROMEO, SICLE, SyN, and four different SPM5 algorithms (“SPM2-type” and regular Normalization, Unified Segmentation, and the DARTEL Toolbox). All of these registrations were preceded by linear registration between the same image pairs using FLIRT. One of the most significant findings of this study is that the relative performances of the registration methods under comparison appear to be little affected by the choice of subject population, labeling protocol, and type of overlap measure. This is important because it suggests that the findings are generalizable to new subject populations that are labeled or evaluated using different labeling protocols. Furthermore, we ranked the 14 methods according to three completely independent analyses (permutation tests, one-way ANOVA tests, and indifference-zone ranking) and derived three almost identical top rankings of the methods. ART, SyN, IRTK, and SPM's DARTEL Toolbox gave the best results according to overlap and distance measures, with ART and SyN delivering the most consistently high accuracy across subjects and label sets. Updates will be published on the http://www.mindboggle.info/papers/ website. PMID:19195496

  14. Technical Note: Development of a combined molecular breast imaging/ultrasound system for diagnostic evaluation of MBI-detected lesions.

    PubMed

    O'Connor, Michael K; Morrow, Melissa M; Tran, Thuy; Hruska, Carrie B; Conners, Amy L; Hunt, Katie N

    2017-02-01

    The purpose of this study was to perform a pilot evaluation of an integrated molecular breast imaging/ultrasound (MBI/US) system designed to enable, in real-time, the registration of US to MBI and diagnostic evaluation of breast lesions detected on MBI. The MBI/US system was constructed by modifying an existing dual-head cadmium zinc telluride (CZT)-based MBI gamma camera. The upper MBI detector head was replaced with a mesh panel, which allowed an ultrasound probe to access the breast. An optical tracking system was used to monitor the location of the ultrasound transducer, referenced to the MBI detector. The lesion depth at which ultrasound was targeted was estimated from analysis of previously acquired dual-head MBI datasets. A software tool was developed to project the US field of view onto the current MBI image. Correlation of lesion location between both modalities with real-time MBI/US scanning was confirmed in a breast phantom model and assessed in 12 patients with a breast lesion detected on MBI. Combined MBI/US scanning allowed for registration of lesions detected on US and MBI as validated in phantom experiments. In patient studies, successful registration was achieved in 8 of 12 (67%) patients, with complete registration achieved in seven and partial registration achieved in one patient. In 4 of 12 (37%) patients, lesion registration was not achieved, partially attributed to uncertainty in lesion depth estimates from MBI. The MBI/US system enabled successful registration of US to MBI in over half of patients studied in this pilot evaluation. Future studies are needed to determine if real-time, registered US imaging of MBI-detected lesions may obviate the need to proceed to more expensive procedures such as contrast-enhanced breast MRI for diagnostic workup or biopsy of MBI findings. © 2016 American Association of Physicists in Medicine.

  15. Automatic intensity-based 3D-to-2D registration of CT volume and dual-energy digital radiography for the detection of cardiac calcification

    NASA Astrophysics Data System (ADS)

    Chen, Xiang; Gilkeson, Robert; Fei, Baowei

    2007-03-01

    We are investigating three-dimensional (3D) to two-dimensional (2D) registration methods for computed tomography (CT) and dual-energy digital radiography (DR) for the detection of coronary artery calcification. CT is an established tool for the diagnosis of coronary artery diseases (CADs). Dual-energy digital radiography could be a cost-effective alternative for screening coronary artery calcification. In order to utilize CT as the "gold standard" to evaluate the ability of DR images for the detection and localization of calcium, we developed an automatic intensity-based 3D-to-2D registration method for 3D CT volumes and 2D DR images. To generate digital rendering radiographs (DRR) from the CT volumes, we developed three projection methods, i.e. Gaussian-weighted projection, threshold-based projection, and average-based projection. We tested normalized cross correlation (NCC) and normalized mutual information (NMI) as similarity measurement. We used the Downhill Simplex method as the search strategy. Simulated projection images from CT were fused with the corresponding DR images to evaluate the localization of cardiac calcification. The registration method was evaluated by digital phantoms, physical phantoms, and clinical data sets. The results from the digital phantoms show that the success rate is 100% with mean errors of less 0.8 mm and 0.2 degree for both NCC and NMI. The registration accuracy of the physical phantoms is 0.34 +/- 0.27 mm. Color overlay and 3D visualization of the clinical data show that the two images are registered well. This is consistent with the improvement of the NMI values from 0.20 +/- 0.03 to 0.25 +/- 0.03 after registration. The automatic 3D-to-2D registration method is accurate and robust and may provide a useful tool to evaluate the dual-energy DR images for the detection of coronary artery calcification.

  16. Study on networking issues of medium earth orbit satellite communications systems

    NASA Technical Reports Server (NTRS)

    Araki, Noriyuki; Shinonaga, Hideyuki; Ito, Yasuhiko

    1993-01-01

    Two networking issues of communications systems with medium earth orbit (MEO) satellites, namely network architectures and location determination and registration methods for hand-held terminals, are investigated in this paper. For network architecture, five candidate architectures are considered and evaluated in terms of signaling traffic. For location determination and registration, two methods are discussed and evaluated.

  17. Selecting registration schemes in case of interstitial lung disease follow-up in CT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vlachopoulos, Georgios; Korfiatis, Panayiotis; Skiadopoulos, Spyros

    Purpose: Primary goal of this study is to select optimal registration schemes in the framework of interstitial lung disease (ILD) follow-up analysis in CT. Methods: A set of 128 multiresolution schemes composed of multiresolution nonrigid and combinations of rigid and nonrigid registration schemes are evaluated, utilizing ten artificially warped ILD follow-up volumes, originating from ten clinical volumetric CT scans of ILD affected patients, to select candidate optimal schemes. Specifically, all combinations of four transformation models (three rigid: rigid, similarity, affine and one nonrigid: third order B-spline), four cost functions (sum-of-square distances, normalized correlation coefficient, mutual information, and normalized mutual information),more » four gradient descent optimizers (standard, regular step, adaptive stochastic, and finite difference), and two types of pyramids (recursive and Gaussian-smoothing) were considered. The selection process involves two stages. The first stage involves identification of schemes with deformation field singularities, according to the determinant of the Jacobian matrix. In the second stage, evaluation methodology is based on distance between corresponding landmark points in both normal lung parenchyma (NLP) and ILD affected regions. Statistical analysis was performed in order to select near optimal registration schemes per evaluation metric. Performance of the candidate registration schemes was verified on a case sample of ten clinical follow-up CT scans to obtain the selected registration schemes. Results: By considering near optimal schemes common to all ranking lists, 16 out of 128 registration schemes were initially selected. These schemes obtained submillimeter registration accuracies in terms of average distance errors 0.18 ± 0.01 mm for NLP and 0.20 ± 0.01 mm for ILD, in case of artificially generated follow-up data. Registration accuracy in terms of average distance error in clinical follow-up data was in the range of 1.985–2.156 mm and 1.966–2.234 mm, for NLP and ILD affected regions, respectively, excluding schemes with statistically significant lower performance (Wilcoxon signed-ranks test, p < 0.05), resulting in 13 finally selected registration schemes. Conclusions: Selected registration schemes in case of ILD CT follow-up analysis indicate the significance of adaptive stochastic gradient descent optimizer, as well as the importance of combined rigid and nonrigid schemes providing high accuracy and time efficiency. The selected optimal deformable registration schemes are equivalent in terms of their accuracy and thus compatible in terms of their clinical outcome.« less

  18. An emergency department registration kiosk can increase HIV screening in high risk patients.

    PubMed

    Hsieh, Yu-Hsiang; Gauvey-Kern, Megan; Peterson, Stephen; Woodfield, Alonzo; Deruggiero, Katherine; Gaydos, Charlotte A; Rothman, Richard E

    2014-12-01

    We evaluated the feasibility and the patient acceptability of integrating a kiosk into routine emergency department (ED) practice for offering HIV testing. The work was conducted in four phases: phase 1 was a baseline, in which external testing staff offered testing at the bedside; phase 2 was a pilot assessment of a prototype kiosk; phase 3 was a pilot implementation and phase 4 was the full implementation with automated login. Feasibility was assessed by the proportion of offering HIV tests, acceptance, completion and result reporting. During the study period, the number of ED patients and eligible patients for screening were similar in the three main phases. However, the number and proportion of patients offered testing of those eligible for screening increased significantly from phase 1 (32%) to phase 3 (37%) and phase 4 (40%). There were slightly higher prevalences of newly diagnosed HIV with kiosk versus bedside testing (phase 1, 0%; phase 3, 0.2%; phase 4, 0.5%). Compared to patients tested at the bedside, patients tested via the kiosk were significantly younger, more likely to be female, to be black, and to report high risk behaviours. ED-based HIV screening via a registration-based kiosk was feasible, yielded similar proportions of testing, and increased the proportion of engagement of higher-risk patients in testing. © The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  19. Agile Multi-Scale Decompositions for Automatic Image Registration

    NASA Technical Reports Server (NTRS)

    Murphy, James M.; Leija, Omar Navarro; Le Moigne, Jacqueline

    2016-01-01

    In recent works, the first and third authors developed an automatic image registration algorithm based on a multiscale hybrid image decomposition with anisotropic shearlets and isotropic wavelets. This prototype showed strong performance, improving robustness over registration with wavelets alone. However, this method imposed a strict hierarchy on the order in which shearlet and wavelet features were used in the registration process, and also involved an unintegrated mixture of MATLAB and C code. In this paper, we introduce a more agile model for generating features, in which a flexible and user-guided mix of shearlet and wavelet features are computed. Compared to the previous prototype, this method introduces a flexibility to the order in which shearlet and wavelet features are used in the registration process. Moreover, the present algorithm is now fully coded in C, making it more efficient and portable than the MATLAB and C prototype. We demonstrate the versatility and computational efficiency of this approach by performing registration experiments with the fully-integrated C algorithm. In particular, meaningful timing studies can now be performed, to give a concrete analysis of the computational costs of the flexible feature extraction. Examples of synthetically warped and real multi-modal images are analyzed.

  20. 32 CFR 1633.5 - Securing information.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 32 National Defense 6 2013-07-01 2013-07-01 false Securing information. 1633.5 Section 1633.5... CLASSIFICATION § 1633.5 Securing information. The classifying authority is authorized to request and receive information whenever such information will assist in determining the proper classification of a registrant. ...

  1. Charismatic authority in modern healthcare: the case of the 'diabetes specialist podiatrist'.

    PubMed

    Bacon, Dawn; Borthwick, Alan M

    2013-09-01

    Professional specialisation is broadly considered to result from increased complexity in professional knowledge and to be linked to specialist education, formalised credentials and registration. However, the degree of formal organisation may vary across professions. In healthcare, although medical specialisation is linked to rigorous selection criteria, formal training programmes and specialist registration, some forms of specialisation in the allied health professions are much less formal. Drawing on Weber's concept of charismatic authority, the establishment of a specialist role in podiatry, the 'diabetes specialist podiatrist', in the absence of codified or credentialed authority, is explored. 'Charismatic' leaders in podiatry, having attracted a following of practitioners, were able to constitute a speciality area of practice in the absence of established career pathways and acquire a degree of legitimacy in the medical field of diabetology. © 2012 The Authors. Sociology of Health & Illness © 2012 Foundation for the Sociology of Health & Illness/JohnWiley & Sons Ltd. Published by John Wiley & Sons Ltd.

  2. Update on the endorsement of CONSORT by high impact factor journals: a survey of journal "Instructions to Authors" in 2014.

    PubMed

    Shamseer, Larissa; Hopewell, Sally; Altman, Douglas G; Moher, David; Schulz, Kenneth F

    2016-06-24

    The CONsolidated Standards Of Reporting Trials (CONSORT) Statement provides a minimum standard set of items to be reported in published clinical trials; it has received widespread recognition within the biomedical publishing community. This research aims to provide an update on the endorsement of CONSORT by high impact medical journals. We performed a cross-sectional examination of the online "Instructions to Authors" of 168 high impact factor (2012) biomedical journals between July and December 2014. We assessed whether the text of the "Instructions to Authors" mentioned the CONSORT Statement and any CONSORT extensions, and we quantified the extent and nature of the journals' endorsements of these. These data were described by frequencies. We also determined whether journals mentioned trial registration and the International Committee of Medical Journal Editors (ICMJE; other than in regards to trial registration) and whether either of these was associated with CONSORT endorsement (relative risk and 95 % confidence interval). We compared our findings to the two previous iterations of this survey (in 2003 and 2007). We also identified the publishers of the included journals. Sixty-three percent (106/168) of the included journals mentioned CONSORT in their "Instructions to Authors." Forty-four endorsers (42 %) explicitly stated that authors "must" use CONSORT to prepare their trial manuscript, 38 % required an accompanying completed CONSORT checklist as a condition of submission, and 39 % explicitly requested the inclusion of a flow diagram with the submission. CONSORT extensions were endorsed by very few journals. One hundred and thirty journals (77 %) mentioned ICMJE, and 106 (63 %) mentioned trial registration. The endorsement of CONSORT by high impact journals has increased over time; however, specific instructions on how CONSORT should be used by authors are inconsistent across journals and publishers. Publishers and journals should encourage authors to use CONSORT and set clear expectations for authors about compliance with CONSORT.

  3. VOMS/VOMRS utilization patterns and convergence plan

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ceccanti, A.; /INFN, CNAF; Ciaschini, V.

    2010-01-01

    The Grid community uses two well-established registration services, which allow users to be authenticated under the auspices of Virtual Organizations (VOs). The Virtual Organization Membership Service (VOMS), developed in the context of the Enabling Grid for E-sciencE (EGEE) project, is an Attribute Authority service that issues attributes expressing membership information of a subject within a VO. VOMS allows to partition users in groups, assign them roles and free-form attributes which are then used to drive authorization decisions. The VOMS administrative application, VOMS-Admin, manages and populates the VOMS database with membership information. The Virtual Organization Management Registration Service (VOMRS), developed atmore » Fermilab, extends the basic registration and management functionalities present in VOMS-Admin. It implements a registration workflow that requires VO usage policy acceptance and membership approval by administrators. VOMRS supports management of multiple grid certificates, and handling users' request for group and role assignments, and membership status. VOMRS is capable of interfacing to local systems with personnel information (e.g. the CERN Human Resource Database) and of pulling relevant member information from them. VOMRS synchronizes the relevant subset of information with VOMS. The recent development of new features in VOMS-Admin raises the possibility of rationalizing the support and converging on a single solution by continuing and extending existing collaborations between EGEE and OSG. Such strategy is supported by WLCG, OSG, US CMS, US Atlas, and other stakeholders worldwide. In this paper, we will analyze features in use by major experiments and the use cases for registration addressed by the mature single solution.« less

  4. VOMS/VOMRS utilization patterns and convergence plan

    NASA Astrophysics Data System (ADS)

    Ceccanti, A.; Ciaschini, V.; Dimou, M.; Garzoglio, G.; Levshina, T.; Traylen, S.; Venturi, V.

    2010-04-01

    The Grid community uses two well-established registration services, which allow users to be authenticated under the auspices of Virtual Organizations (VOs). The Virtual Organization Membership Service (VOMS), developed in the context of the Enabling Grid for E-sciencE (EGEE) project, is an Attribute Authority service that issues attributes expressing membership information of a subject within a VO. VOMS allows to partition users in groups, assign them roles and free-form attributes which are then used to drive authorization decisions. The VOMS administrative application, VOMS-Admin, manages and populates the VOMS database with membership information. The Virtual Organization Management Registration Service (VOMRS), developed at Fermilab, extends the basic registration and management functionalities present in VOMS-Admin. It implements a registration workflow that requires VO usage policy acceptance and membership approval by administrators. VOMRS supports management of multiple grid certificates, and handling users' request for group and role assignments, and membership status. VOMRS is capable of interfacing to local systems with personnel information (e.g. the CERN Human Resource Database) and of pulling relevant member information from them. VOMRS synchronizes the relevant subset of information with VOMS. The recent development of new features in VOMS-Admin raises the possibility of rationalizing the support and converging on a single solution by continuing and extending existing collaborations between EGEE and OSG. Such strategy is supported by WLCG, OSG, US CMS, US Atlas, and other stakeholders worldwide. In this paper, we will analyze features in use by major experiments and the use cases for registration addressed by the mature single solution.

  5. Using patient-specific phantoms to evaluate deformable image registration algorithms for adaptive radiation therapy

    PubMed Central

    Stanley, Nick; Glide-Hurst, Carri; Kim, Jinkoo; Adams, Jeffrey; Li, Shunshan; Wen, Ning; Chetty, Indrin J.; Zhong, Hualiang

    2014-01-01

    The quality of adaptive treatment planning depends on the accuracy of its underlying deformable image registration (DIR). The purpose of this study is to evaluate the performance of two DIR algorithms, B-spline–based deformable multipass (DMP) and deformable demons (Demons), implemented in a commercial software package. Evaluations were conducted using both computational and physical deformable phantoms. Based on a finite element method (FEM), a total of 11 computational models were developed from a set of CT images acquired from four lung and one prostate cancer patients. FEM generated displacement vector fields (DVF) were used to construct the lung and prostate image phantoms. Based on a fast-Fourier transform technique, image noise power spectrum was incorporated into the prostate image phantoms to create simulated CBCT images. The FEM-DVF served as a gold standard for verification of the two registration algorithms performed on these phantoms. The registration algorithms were also evaluated at the homologous points quantified in the CT images of a physical lung phantom. The results indicated that the mean errors of the DMP algorithm were in the range of 1.0 ~ 3.1 mm for the computational phantoms and 1.9 mm for the physical lung phantom. For the computational prostate phantoms, the corresponding mean error was 1.0–1.9 mm in the prostate, 1.9–2.4 mm in the rectum, and 1.8–2.1 mm over the entire patient body. Sinusoidal errors induced by B-spline interpolations were observed in all the displacement profiles of the DMP registrations. Regions of large displacements were observed to have more registration errors. Patient-specific FEM models have been developed to evaluate the DIR algorithms implemented in the commercial software package. It has been found that the accuracy of these algorithms is patient-dependent and related to various factors including tissue deformation magnitudes and image intensity gradients across the regions of interest. This may suggest that DIR algorithms need to be verified for each registration instance when implementing adaptive radiation therapy. PMID:24257278

  6. Using patient‐specific phantoms to evaluate deformable image registration algorithms for adaptive radiation therapy

    PubMed Central

    Stanley, Nick; Glide‐Hurst, Carri; Kim, Jinkoo; Adams, Jeffrey; Li, Shunshan; Wen, Ning; Chetty, Indrin J

    2013-01-01

    The quality of adaptive treatment planning depends on the accuracy of its underlying deformable image registration (DIR). The purpose of this study is to evaluate the performance of two DIR algorithms, B‐spline‐based deformable multipass (DMP) and deformable demons (Demons), implemented in a commercial software package. Evaluations were conducted using both computational and physical deformable phantoms. Based on a finite element method (FEM), a total of 11 computational models were developed from a set of CT images acquired from four lung and one prostate cancer patients. FEM generated displacement vector fields (DVF) were used to construct the lung and prostate image phantoms. Based on a fast‐Fourier transform technique, image noise power spectrum was incorporated into the prostate image phantoms to create simulated CBCT images. The FEM‐DVF served as a gold standard for verification of the two registration algorithms performed on these phantoms. The registration algorithms were also evaluated at the homologous points quantified in the CT images of a physical lung phantom. The results indicated that the mean errors of the DMP algorithm were in the range of 1.0~3.1mm for the computational phantoms and 1.9 mm for the physical lung phantom. For the computational prostate phantoms, the corresponding mean error was 1.0–1.9 mm in the prostate, 1.9–2.4 mm in the rectum, and 1.8–2.1 mm over the entire patient body. Sinusoidal errors induced by B‐spline interpolations were observed in all the displacement profiles of the DMP registrations. Regions of large displacements were observed to have more registration errors. Patient‐specific FEM models have been developed to evaluate the DIR algorithms implemented in the commercial software package. It has been found that the accuracy of these algorithms is patient‐dependent and related to various factors including tissue deformation magnitudes and image intensity gradients across the regions of interest. This may suggest that DIR algorithms need to be verified for each registration instance when implementing adaptive radiation therapy. PACS numbers: 87.10.Kn, 87.55.km, 87.55.Qr, 87.57.nj

  7. Evaluation of image registration in PET/CT of the liver and recommendations for optimized imaging.

    PubMed

    Vogel, Wouter V; van Dalen, Jorn A; Wiering, Bas; Huisman, Henkjan; Corstens, Frans H M; Ruers, Theo J M; Oyen, Wim J G

    2007-06-01

    Multimodality PET/CT of the liver can be performed with an integrated (hybrid) PET/CT scanner or with software fusion of dedicated PET and CT. Accurate anatomic correlation and good image quality of both modalities are important prerequisites, regardless of the applied method. Registration accuracy is influenced by breathing motion differences on PET and CT, which may also have impact on (attenuation correction-related) artifacts, especially in the upper abdomen. The impact of these issues was evaluated for both hybrid PET/CT and software fusion, focused on imaging of the liver. Thirty patients underwent hybrid PET/CT, 20 with CT during expiration breath-hold (EB) and 10 with CT during free breathing (FB). Ten additional patients underwent software fusion of dedicated PET and dedicated expiration breath-hold CT (SF). The image registration accuracy was evaluated at the location of liver borders on CT and uncorrected PET images and at the location of liver lesions. Attenuation-correction artifacts were evaluated by comparison of liver borders on uncorrected and attenuation-corrected PET images. CT images were evaluated for the presence of breathing artifacts. In EB, 40% of patients had an absolute registration error of the diaphragm in the craniocaudal direction of >1 cm (range, -16 to 44 mm), and 45% of lesions were mispositioned >1 cm. In 50% of cases, attenuation-correction artifacts caused a deformation of the liver dome on PET of >1 cm. Poor compliance to breath-hold instructions caused CT artifacts in 55% of cases. In FB, 30% had registration errors of >1 cm (range, -4 to 16 mm) and PET artifacts were less extensive, but all CT images had breathing artifacts. As SF allows independent alignment of PET and CT, no registration errors or artifacts of >1 cm of the diaphragm occurred. Hybrid PET/CT of the liver may have significant registration errors and artifacts related to breathing motion. The extent of these issues depends on the selected breathing protocol and the speed of the CT scanner. No protocol or scanner can guarantee perfect image fusion. On the basis of these findings, recommendations were formulated with regard to scanner requirements, breathing protocols, and reporting.

  8. Draft Registration Implementation. Report Together with Dissenting Individual, Additional, and Separate Views. House of Representatives, Committee on Education and Labor, Ninety-eighth Congress, First Session.

    ERIC Educational Resources Information Center

    Congress of the U.S., Washington, DC. House Committee on Education and Labor.

    A report on a bill to delay the effective date for the denial of federal aid to students who have failed to comply with draft registration requirements is presented. The bill also directs the Comptroller General to conduct an ongoing study of the effectiveness of the Department of Defense Authorization Act of 1983 (Solomon/Hayakawa amendment) in…

  9. Complexities of policy-driven pre-registration nursing curricula.

    PubMed

    McCarthy, Jilian; Holt, Maxine

    This article discusses the challenges faced by two nurse educators when incorporating current health policy into a new pre-registration nursing curriculum, using public health and e-learning as examples. The article, which features the results of preliminary work from the authors' doctoral studies, includes summaries of students' discourses about e-learning and public health and how these subject areas are perceived by learners. Practical solutions to the challenges encountered are suggested.

  10. Registration of central paths and colonic polyps between supine and prone scans in computed tomography colonography: Pilot study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Li Ping; Napel, Sandy; Acar, Burak

    2004-10-01

    Computed tomography colonography (CTC) is a minimally invasive method that allows the evaluation of the colon wall from CT sections of the abdomen/pelvis. The primary goal of CTC is to detect colonic polyps, precursors to colorectal cancer. Because imperfect cleansing and distension can cause portions of the colon wall to be collapsed, covered with water, and/or covered with retained stool, patients are scanned in both prone and supine positions. We believe that both reading efficiency and computer aided detection (CAD) of CTC images can be improved by accurate registration of data from the supine and prone positions. We developed amore » two-stage approach that first registers the colonic central paths using a heuristic and automated algorithm and then matches polyps or polyp candidates (CAD hits) by a statistical approach. We evaluated the registration algorithm on 24 patient cases. After path registration, the mean misalignment distance between prone and supine identical anatomic landmarks was reduced from 47.08 to 12.66 mm, a 73% improvement. The polyp registration algorithm was specifically evaluated using eight patient cases for which radiologists identified polyps separately for both supine and prone data sets, and then manually registered corresponding pairs. The algorithm correctly matched 78% of these pairs without user input. The algorithm was also applied to the 30 highest-scoring CAD hits in the prone and supine scans and showed a success rate of 50% in automatically registering corresponding polyp pairs. Finally, we computed the average number of CAD hits that need to be manually compared in order to find the correct matches among the top 30 CAD hits. With polyp registration, the average number of comparisons was 1.78 per polyp, as opposed to 4.28 comparisons without polyp registration.« less

  11. Quantitative Analysis of Geometry and Lateral Symmetry of Proximal Middle Cerebral Artery.

    PubMed

    Peter, Roman; Emmer, Bart J; van Es, Adriaan C G M; van Walsum, Theo

    2017-10-01

    The purpose of our work is to quantitatively assess clinically relevant geometric properties of proximal middle cerebral arteries (pMCA), to investigate the degree of their lateral symmetry, and to evaluate whether the pMCA can be modeled by using state-of-the-art deformable image registration of the ipsi- and contralateral hemispheres. Individual pMCA segments were identified, quantified, and statistically evaluated on a set of 55 publicly available magnetic resonance angiography time-of-flight images. Rigid and deformable image registrations were used for geometric alignment of the ipsi- and contralateral hemispheres. Lateral symmetry of relevant geometric properties was evaluated before and after the image registration. No significant lateral differences regarding tortuosity and diameters of contralateral M1 segments of pMCA were identified. Regarding the length of M1 segment, 44% of all subjects could be considered laterally symmetrical. Dominant M2 segment was identified in 30% of men and 9% of women in both brain hemispheres. Deformable image registration performed significantly better (P < .01) than rigid registration with regard to distances between the ipsi- and the contralateral centerlines of M1 segments (1.5 ± 1.1 mm versus 2.8 ± 1.2 mm respectively) and between the M1 and the anterior cerebral artery (ACA) branching points (1.6 ± 1.4 mm after deformable registration). Although natural lateral variation of the length of M1 may not allow for sufficient modeling of the complete pMCA, deformable image registration of the contralateral brain hemisphere to the ipsilateral hemisphere is feasible for localization of ACA-M1 branching point and for modeling 71 ± 23% of M1 segment. Copyright © 2017 National Stroke Association. Published by Elsevier Inc. All rights reserved.

  12. Evaluating the utility of 3D TRUS image information in guiding intra-procedure registration for motion compensation

    NASA Astrophysics Data System (ADS)

    De Silva, Tharindu; Cool, Derek W.; Romagnoli, Cesare; Fenster, Aaron; Ward, Aaron D.

    2014-03-01

    In targeted 3D transrectal ultrasound (TRUS)-guided biopsy, patient and prostate movement during the procedure can cause target misalignments that hinder accurate sampling of pre-planned suspicious tissue locations. Multiple solutions have been proposed for motion compensation via registration of intra-procedural TRUS images to a baseline 3D TRUS image acquired at the beginning of the biopsy procedure. While 2D TRUS images are widely used for intra-procedural guidance, some solutions utilize richer intra-procedural images such as bi- or multi-planar TRUS or 3D TRUS, acquired by specialized probes. In this work, we measured the impact of such richer intra-procedural imaging on motion compensation accuracy, to evaluate the tradeoff between cost and complexity of intra-procedural imaging versus improved motion compensation. We acquired baseline and intra-procedural 3D TRUS images from 29 patients at standard sextant-template biopsy locations. We used the planes extracted from the 3D intra-procedural scans to simulate 2D and 3D information available in different clinically relevant scenarios for registration. The registration accuracy was evaluated by calculating the target registration error (TRE) using manually identified homologous fiducial markers (micro-calcifications). Our results indicate that TRE improves gradually when the number of intra-procedural imaging planes used in registration is increased. Full 3D TRUS information helps the registration algorithm to robustly converge to more accurate solutions. These results can also inform the design of a fail-safe workflow during motion compensation in a system using a tracked 2D TRUS probe, by prescribing rotational acquisitions that can be performed quickly and easily by the physician immediately prior to needle targeting.

  13. Consistency of magnetoencephalographic functional connectivity and network reconstruction using a template versus native MRI for co‐registration

    PubMed Central

    Douw, Linda; Stam, Cornelis J.; Tewarie, Prejaas; Hillebrand, Arjan

    2017-01-01

    Abstract Introduction Studies using functional connectivity and network analyses based on magnetoencephalography (MEG) with source localization are rapidly emerging in neuroscientific literature. However, these analyses currently depend on the availability of costly and sometimes burdensome individual MR scans for co‐registration. We evaluated the consistency of these measures when using a template MRI, instead of native MRI, for the analysis of functional connectivity and network topology. Methods Seventeen healthy participants underwent resting‐state eyes‐closed MEG and anatomical MRI. These data were projected into source space using an atlas‐based peak voxel and a centroid beamforming approach either using (1) participants’ native MRIs or (2) the Montreal Neurological Institute's template. For both methods, time series were reconstructed from 78 cortical atlas regions. Relative power was determined in six classical frequency bands per region and globally averaged. Functional connectivity (phase lag index) between each pair of regions was calculated. The adjacency matrices were then used to reconstruct functional networks, of which regional and global metrics were determined. Intraclass correlation coefficients were calculated and Bland–Altman plots were made to quantify the consistency and potential bias of the use of template versus native MRI. Results Co‐registration with the template yielded largely consistent relative power, connectivity, and network estimates compared to native MRI. Discussion These findings indicate that there is no (systematic) bias or inconsistency between template and native MRI co‐registration of MEG. They open up possibilities for retrospective and prospective analyses to MEG datasets in the general population that have no native MRIs available. Hum Brain Mapp, 2017. © 2017 The Authors Human Brain Mapping Published by Wiley Periodicals, Inc. Hum Brain Mapp 39:104–119, 2018. © 2017 Wiley Periodicals, Inc. PMID:28990264

  14. Block matching and Wiener filtering approach to optical turbulence mitigation and its application to simulated and real imagery with quantitative error analysis

    NASA Astrophysics Data System (ADS)

    Hardie, Russell C.; Rucci, Michael A.; Dapore, Alexander J.; Karch, Barry K.

    2017-07-01

    We present a block-matching and Wiener filtering approach to atmospheric turbulence mitigation for long-range imaging of extended scenes. We evaluate the proposed method, along with some benchmark methods, using simulated and real-image sequences. The simulated data are generated with a simulation tool developed by one of the authors. These data provide objective truth and allow for quantitative error analysis. The proposed turbulence mitigation method takes a sequence of short-exposure frames of a static scene and outputs a single restored image. A block-matching registration algorithm is used to provide geometric correction for each of the individual input frames. The registered frames are then averaged, and the average image is processed with a Wiener filter to provide deconvolution. An important aspect of the proposed method lies in how we model the degradation point spread function (PSF) for the purposes of Wiener filtering. We use a parametric model that takes into account the level of geometric correction achieved during image registration. This is unlike any method we are aware of in the literature. By matching the PSF to the level of registration in this way, the Wiener filter is able to fully exploit the reduced blurring achieved by registration. We also describe a method for estimating the atmospheric coherence diameter (or Fried parameter) from the estimated motion vectors. We provide a detailed performance analysis that illustrates how the key tuning parameters impact system performance. The proposed method is relatively simple computationally, yet it has excellent performance in comparison with state-of-the-art benchmark methods in our study.

  15. Evaluation of low-dose limits in 3D-2D rigid registration for surgical guidance

    NASA Astrophysics Data System (ADS)

    Uneri, A.; Wang, A. S.; Otake, Y.; Kleinszig, G.; Vogt, S.; Khanna, A. J.; Gallia, G. L.; Gokaslan, Z. L.; Siewerdsen, J. H.

    2014-09-01

    An algorithm for intensity-based 3D-2D registration of CT and C-arm fluoroscopy is evaluated for use in surgical guidance, specifically considering the low-dose limits of the fluoroscopic x-ray projections. The registration method is based on a framework using the covariance matrix adaptation evolution strategy (CMA-ES) to identify the 3D patient pose that maximizes the gradient information similarity metric. Registration performance was evaluated in an anthropomorphic head phantom emulating intracranial neurosurgery, using target registration error (TRE) to characterize accuracy and robustness in terms of 95% confidence upper bound in comparison to that of an infrared surgical tracking system. Three clinical scenarios were considered: (1) single-view image + guidance, wherein a single x-ray projection is used for visualization and 3D-2D guidance; (2) dual-view image + guidance, wherein one projection is acquired for visualization, combined with a second (lower-dose) projection acquired at a different C-arm angle for 3D-2D guidance; and (3) dual-view guidance, wherein both projections are acquired at low dose for the purpose of 3D-2D guidance alone (not visualization). In each case, registration accuracy was evaluated as a function of the entrance surface dose associated with the projection view(s). Results indicate that images acquired at a dose as low as 4 μGy (approximately one-tenth the dose of a typical fluoroscopic frame) were sufficient to provide TRE comparable or superior to that of conventional surgical tracking, allowing 3D-2D guidance at a level of dose that is at most 10% greater than conventional fluoroscopy (scenario #2) and potentially reducing the dose to approximately 20% of the level in a conventional fluoroscopically guided procedure (scenario #3).

  16. Performance evaluations of demons and free form deformation algorithms for the liver region.

    PubMed

    Wang, Hui; Gong, Guanzhong; Wang, Hongjun; Li, Dengwang; Yin, Yong; Lu, Jie

    2014-04-01

    We investigated the influence of breathing motion on radiation therapy according to four- dimensional computed tomography (4D-CT) technology and indicated the registration of 4D-CT images was significant. The demons algorithm in two interpolation modes was compared to the FFD model algorithm to register the different phase images of 4D-CT in tumor tracking, using iodipin as verification. Linear interpolation was used in both mode 1 and mode 2. Mode 1 set outside pixels to nearest pixel, while mode 2 set outside pixels to zero. We used normalized mutual information (NMI), sum of squared differences, modified Hausdorff-distance, and registration speed to evaluate the performance of each algorithm. The average NMI after demons registration method in mode 1 improved 1.76% and 4.75% when compared to mode 2 and FFD model algorithm, respectively. Further, the modified Hausdorff-distance was no different between demons modes 1 and 2, but mode 1 was 15.2% lower than FFD. Finally, demons algorithm has the absolute advantage in registration speed. The demons algorithm in mode 1 was therefore found to be much more suitable for the registration of 4D-CT images. The subtractions of floating images and reference image before and after registration by demons further verified that influence of breathing motion cannot be ignored and the demons registration method is feasible.

  17. Groupwise registration of MR brain images with tumors.

    PubMed

    Tang, Zhenyu; Wu, Yihong; Fan, Yong

    2017-08-04

    A novel groupwise image registration framework is developed for registering MR brain images with tumors. Our method iteratively estimates a normal-appearance counterpart for each tumor image to be registered and constructs a directed graph (digraph) of normal-appearance images to guide the groupwise image registration. Particularly, our method maps each tumor image to its normal appearance counterpart by identifying and inpainting brain tumor regions with intensity information estimated using a low-rank plus sparse matrix decomposition based image representation technique. The estimated normal-appearance images are groupwisely registered to a group center image guided by a digraph of images so that the total length of 'image registration paths' to be the minimum, and then the original tumor images are warped to the group center image using the resulting deformation fields. We have evaluated our method based on both simulated and real MR brain tumor images. The registration results were evaluated with overlap measures of corresponding brain regions and average entropy of image intensity information, and Wilcoxon signed rank tests were adopted to compare different methods with respect to their regional overlap measures. Compared with a groupwise image registration method that is applied to normal-appearance images estimated using the traditional low-rank plus sparse matrix decomposition based image inpainting, our method achieved higher image registration accuracy with statistical significance (p  =  7.02  ×  10 -9 ).

  18. Application of tolerance limits to the characterization of image registration performance.

    PubMed

    Fedorov, Andriy; Wells, William M; Kikinis, Ron; Tempany, Clare M; Vangel, Mark G

    2014-07-01

    Deformable image registration is used increasingly in image-guided interventions and other applications. However, validation and characterization of registration performance remain areas that require further study. We propose an analysis methodology for deriving tolerance limits on the initial conditions for deformable registration that reliably lead to a successful registration. This approach results in a concise summary of the probability of registration failure, while accounting for the variability in the test data. The (β, γ) tolerance limit can be interpreted as a value of the input parameter that leads to successful registration outcome in at least 100β% of cases with the 100γ% confidence. The utility of the methodology is illustrated by summarizing the performance of a deformable registration algorithm evaluated in three different experimental setups of increasing complexity. Our examples are based on clinical data collected during MRI-guided prostate biopsy registered using publicly available deformable registration tool. The results indicate that the proposed methodology can be used to generate concise graphical summaries of the experiments, as well as a probabilistic estimate of the registration outcome for a future sample. Its use may facilitate improved objective assessment, comparison and retrospective stress-testing of deformable.

  19. Chemical leasing business models: a contribution to the effective risk management of chemical substances.

    PubMed

    Ohl, Cornelia; Moser, Frank

    2007-08-01

    Chemicals indisputably contribute greatly to the well-being of modern societies. Apart from such benefits, however, chemicals often pose serious threats to human health and the environment when improperly handled. Therefore, the European Commission has proposed a regulatory framework for the Registration, Evaluation and Authorization of Chemicals (REACH) that requires companies using chemicals to gather pertinent information on the properties of these substances. In this article, we argue that the crucial aspect of this information management may be the honesty and accuracy of the transfer of relevant knowledge from the producer of a chemical to its user. This may be particularly true if the application of potentially hazardous chemicals is not part of the user's core competency. Against this background, we maintain that the traditional sales concept provides no incentives for transferring this knowledge. The reason is that increased user knowledge of a chemical's properties may raise the efficiency of its application. That is, excessive and unnecessary usage will be eliminated. This, in turn, would lower the amount of chemicals sold and in competitive markets directly decrease profits of the producer. Through the introduction of chemical leasing business models, we attempt to present a strategy to overcome the incentive structure of classical sales models, which is counterproductive for the transfer of knowledge. By introducing two models (a Model A that differs least and a Model B that differs most from traditional sales concepts), we demonstrate that chemical leasing business models are capable of accomplishing the goal of Registration, Evaluation and Authorization of Chemicals: to effectively manage the risk of chemicals by reducing the total quantity of chemicals used, either by a transfer of applicable knowledge from the lessor to the lessee (Model A) or by efficient application of the chemical by the lessor him/herself (Model B).

  20. Analytical and experimental design and analysis of an optimal processor for image registration

    NASA Technical Reports Server (NTRS)

    Mcgillem, C. D. (Principal Investigator); Svedlow, M.; Anuta, P. E.

    1976-01-01

    The author has identified the following significant results. A quantitative measure of the registration processor accuracy in terms of the variance of the registration error was derived. With the appropriate assumptions, the variance was shown to be inversely proportional to the square of the effective bandwidth times the signal to noise ratio. The final expressions were presented to emphasize both the form and simplicity of their representation. In the situation where relative spatial distortions exist between images to be registered, expressions were derived for estimating the loss in output signal to noise ratio due to these spatial distortions. These results are in terms of a reduction factor.

  1. Prevalence of counterfeit anthelminthic medicines: a cross-sectional survey in Cambodia.

    PubMed

    Khan, Mohiuddin Hussain; Okumura, Junko; Sovannarith, Tey; Nivanna, Nam; Akazawa, Manabu; Kimura, Kazuko

    2010-05-01

    To assess the prevalence of counterfeit anthelminthic medicines in Cambodia, and to determine influential factors. Commonly used anthelminthic medicines were collected from private drug outlets. Medicines were carefully observed including their registration labelling, and their authenticity was investigated with the manufacturers and the Medicines Regulatory Authorities. Samples were analysed by High-Performance Liquid Chromatography at the National Health Product Quality Control Centre, Cambodia. Two hundred and three samples of anthelminthics were collected from 137 drug stores. Domestic products constituted 36.9%. Of 196 samples which were verified for registration, 15.8% were not registered. Of 165 samples successfully investigated for their authenticity, 7 (4.2%) were identified as counterfeit. All of these medicines were purchased in open packs or containers, and most of them were foreign manufactured and/or without registration. The results of our survey urge strict implementation of drug registration and vigilance on the availability of unregistered medicines to combat counterfeit medicines in Cambodia.

  2. Annular Electric Discharge as an Initiator of Combustion in Supersonic Flow

    DTIC Science & Technology

    2009-02-01

    Flow 5a. CONTRACT NUMBER ISTC Registration No: 3833P 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) Kossyi Igor Antonovich...REPORT NUMBER(S) ISTC 07-7012 12. DISTRIBUTION/AVAILABILITY STATEMENT Approved for public release; distribution is unlimited. 13. SUPPLEMENTARY...

  3. Author Identification Systems

    ERIC Educational Resources Information Center

    Wagner, A. Ben

    2009-01-01

    Many efforts are currently underway to disambiguate author names and assign unique identification numbers so that publications by a given scholar can be reliably grouped together. This paper reviews a number of operational and in-development services. Some systems like ResearcherId.Com depend on self-registration and self-identification of a…

  4. 75 FR 77305 - Security-Based Swap Data Repository Registration, Duties, and Core Principles

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-12-10

    ... authorities can access and analyze the data from secure, central locations to better monitor for systemic risk... authorities information to help limit systemic risk and by promoting stability through enhanced transparency...) performing market surveillance, prudential supervision, and macroprudential (systemic risk) supervision; and...

  5. Evaluation of a Hockey Deceased Organ Donation Awareness Campaign: A Population-Based Cohort Study

    PubMed Central

    Naylor, Kyla L.; McKenzie, Susan; Cherry, Cindy; McArthur, Eric; Li, Alvin H.; McCallum, Megan K.; Kim, S. Joseph; Prakash, Versha; Knoll, Gregory A.; Garg, Amit X.

    2017-01-01

    Background: The Kidney Foundation of Canada developed a pilot campaign to educate persons attending junior hockey league games in London, Ontario, Canada, on deceased organ donation. Objective: To evaluate the impact of a hockey campaign on the number of new organ and tissue donor registrants. Design: Population-based retrospective cohort study. Setting: Residents of London, Ontario. Patients: We included 255 476 individuals eligible to register for organ donation with a London, Ontario postal code. Measurements: We compared the number of new deceased organ donor registrants in London, Ontario, during the campaign period (March 12 to April 16, 2015) with 3 different time periods (December 30, 2014 to February 3, 2015; February 4 to March 11, 2015; April 17 to May 22, 2015). We also compared registration rates in London with 2 Ontario cities (Kitchener-Waterloo and Hamilton) matching in a 1:1 ratio on age, sex, and income quintile. Methods: To compare registrations across time periods, we used binomial regression with an identity link function and generalized estimating equations with an independence correlation structure. We used modified Poisson regression to compare registration rates between cities. Results: During the campaign period, there were slightly more registrations (1218 registered of 252 832 unregistered individuals [0.48%]) compared with an earlier time period (risk difference: 0.09%; 95% confidence interval [CI]: 0.05%-0.12%). However, there was no significant difference compared with 2 time periods immediately before and after the campaign. London had slightly more registrations during the campaign period compared with the matched city of Hamilton (1180 registered of 236 582 unregistered individuals [0.50%] vs 490 registered of 236 582 unregistered individuals [0.21%]; risk ratio: 2.41; 95% CI: 2.17-2.68). The registration rate in London did not significantly differ from Kitchener-Waterloo. Limitations: Unable to conclude whether the minor increase in deceased organ donor registration was the result of the campaign or other factors (e.g., simultaneous organ registration events, seasonality). Conclusions: Overall, a minor increase in deceased organ donor registration was observed during the hockey organ donation awareness campaign; however, the specific impact of the campaign on organ donor registration could not be determined. PMID:28748101

  6. Process Evaluation of a School-Based Education Program about Organ Donation and Registration, and the Intention for Continuance

    ERIC Educational Resources Information Center

    Reubsaet, A.; Reinaerts, E. B. M.; Brug, J.; van Hooff, J. P.; van den Borne, H. W.

    2004-01-01

    This paper describes the process evaluation of an organ donation education program for high school students aged 15-18 years of which the effectiveness was established. The program consisted of three components: a video with group discussion, an interactive computer-tailored program and a registration training session. A cross-sectional survey was…

  7. Speeding Access to Vaccines and Medicines in Low- and Middle-Income Countries: A Case for Change and a Framework for Optimized Product Market Authorization

    PubMed Central

    Ahonkhai, Vincent; Portet, Alexandre; Hartman, Dan

    2016-01-01

    Background The United Nations Millennium Development Goals galvanized global efforts to alleviate suffering of the world’s poorest people through unprecedented public-private partnerships. Donor aid agencies have demonstrably saved millions of lives that might otherwise have been lost to disease through increased access to quality-assured vaccines and medicines. Yet, the introduction of these health interventions in low- and middle-income countries (LMICs) continues to face a time lag due to factors which remain poorly understood. Methods and Findings A recurring theme from our partnership engagements was that an optimized regulatory process would contribute to improved access to quality health products. Therefore, we investigated the current system for medicine and vaccine registration in LMICs as part of our comprehensive regulatory strategy. Here, we report a fact base of the registration timelines for vaccines and drugs used to treat certain communicable diseases in LMICs. We worked with a broad set of stakeholders, including the World Health Organization’s prequalification team, national regulatory authorities, manufacturers, procurers, and other experts, and collected data on the timelines between first submission and last approval of applications for product registration sub-Saharan Africa. We focused on countries with the highest burden of communicable disease and the greatest need for the products studied. The data showed a typical lag of 4 to 7 years between the first regulatory submission which was usually to a regulatory agency in a high-income country, and the final approval in Sub-Saharan Africa. Two of the three typical registration steps which products undergo before delivery in the countries involve lengthy timelines. Failure to leverage or rely on the findings from reviews already performed by competent regulatory authorities, disparate requirements for product approval by the countries, and lengthy timelines by manufacturers to respond to regulatory queries were key underlying factors for the delays. Conclusions We propose a series of measures which we developed in close collaboration with key stakeholders that could be taken to reduce registration time and to make safe, effective medicines more quickly available in countries where they are most needed. Many of these recommendations are being implemented by the responsible stakeholders, including the WHO prequalification team and the national regulatory authorities in Sub-Saharan Africa. Those efforts will be the focus of subsequent publications by the pertinent groups. PMID:27851831

  8. Speeding Access to Vaccines and Medicines in Low- and Middle-Income Countries: A Case for Change and a Framework for Optimized Product Market Authorization.

    PubMed

    Ahonkhai, Vincent; Martins, Samuel F; Portet, Alexandre; Lumpkin, Murray; Hartman, Dan

    2016-01-01

    The United Nations Millennium Development Goals galvanized global efforts to alleviate suffering of the world's poorest people through unprecedented public-private partnerships. Donor aid agencies have demonstrably saved millions of lives that might otherwise have been lost to disease through increased access to quality-assured vaccines and medicines. Yet, the introduction of these health interventions in low- and middle-income countries (LMICs) continues to face a time lag due to factors which remain poorly understood. A recurring theme from our partnership engagements was that an optimized regulatory process would contribute to improved access to quality health products. Therefore, we investigated the current system for medicine and vaccine registration in LMICs as part of our comprehensive regulatory strategy. Here, we report a fact base of the registration timelines for vaccines and drugs used to treat certain communicable diseases in LMICs. We worked with a broad set of stakeholders, including the World Health Organization's prequalification team, national regulatory authorities, manufacturers, procurers, and other experts, and collected data on the timelines between first submission and last approval of applications for product registration sub-Saharan Africa. We focused on countries with the highest burden of communicable disease and the greatest need for the products studied. The data showed a typical lag of 4 to 7 years between the first regulatory submission which was usually to a regulatory agency in a high-income country, and the final approval in Sub-Saharan Africa. Two of the three typical registration steps which products undergo before delivery in the countries involve lengthy timelines. Failure to leverage or rely on the findings from reviews already performed by competent regulatory authorities, disparate requirements for product approval by the countries, and lengthy timelines by manufacturers to respond to regulatory queries were key underlying factors for the delays. We propose a series of measures which we developed in close collaboration with key stakeholders that could be taken to reduce registration time and to make safe, effective medicines more quickly available in countries where they are most needed. Many of these recommendations are being implemented by the responsible stakeholders, including the WHO prequalification team and the national regulatory authorities in Sub-Saharan Africa. Those efforts will be the focus of subsequent publications by the pertinent groups.

  9. Can we well assess the relative efficacy and tolerability of a new drug versus others at the time of marketing authorization using mixed treatment comparisons? A detailed illustration with escitalopram

    PubMed Central

    Llorca, Pierre-Michel; Lançon, Christophe; Brignone, Mélanie; Painchault, Caroline; Rive, Benoit; Toumi, Mondher; François, Clément

    2015-01-01

    Objective To assess the variation of relative efficacy and tolerability of an antidepressant versus others based on both pre-marketing (registration studies) and post-marketing studies versus pre-marketing studies only in patients with major depressive disorder. Methods The relative efficacy and tolerability of antidepressants was assessed by mixed treatment comparisons (MTCs) using data acquired over two time periods: before registration of the reference drug escitalopram (1989–2002) and up to 5 years later (1989–2007). Ranking probability outputs were presented for efficacy, using change from baseline to 8 weeks on Montgomery–Åsberg Depression Rating Scale total score, and tolerability, using withdrawals due to adverse events. Results The relative efficacy and tolerability of some selected antidepressants, including escitalopram, varied considerably over the two time periods. The improved relative efficacy and tolerability of escitalopram over time, compared with citalopram, was demonstrated by greater separation of ranking probability curves for efficacy and tolerability. In 2002, escitalopram ranked low with 13.9% and 5.1% probability of being in the top four antidepressants’ relative efficacy and tolerability, respectively. In 2007, ranking probabilities for relative efficacy and tolerability of escitalopram increased to 52.5% and 82.1%, respectively. Conclusions Time of marketing authorization may not be the most appropriate time to evaluate the relative efficacy and tolerability of a new antidepressant based on MTC approach due to the asymmetry of information between new and older compounds. However, the first evaluation of relative effect of a new drug for health technology assessment recommendations is commonly done at this time. Re-evaluation of a drug several years after its launch is likely to provide a more accurate indication of its relative efficacy and tolerability. PMID:27123184

  10. The European Union's REACH regulation: a review of its history and requirements.

    PubMed

    Williams, E Spencer; Panko, Julie; Paustenbach, Dennis J

    2009-01-01

    In 2006, the European Union (EU) promulgated a monumental regulatory initiative for the Registration, Evaluation, Authorization, and Restriction of Chemicals (REACH). To date, several thousand pages of text have been needed to describe the expectations of this regulation. There were numerous reasons for the promulgation of REACH, but, by and large, it is an extension of the global desire to produce fewer industrial chemicals, to understand the possible human and ecological hazards of those that are produced, and to insure that any major threat is anticipated, as well as prevented. Most industry-related groups consider it the most wide-ranging and costly regulatory initiatives related to health risk assessment ever to be promulgated. This review presents a description of REACH that should inform scientists, managers, and others about its objectives and the means to satisfy them. Registration is required for all chemicals manufactured or imported into the EU, unless specifically exempted. Registration is expected to be a collaborative process among companies, which will generate a dossier containing data on physicochemical characteristics, as well as toxicological and ecotoxicological properties. Though the magnitude of the gaps in the data required for registration is uncertain at this point, it is clear that basic toxicology testing will have to be conducted for many chemical substances that have not undergone formal review up to this point. For many chemicals, an examination of hazards and risks arising from the use of these substances will also be required in the form of a chemical safety report (CSR). Beginning with the dual processes of dossier and substance evaluation, the European Chemicals Agency (ECHA), the Member States of the EU, and the European Commission will identify chemicals that may pose unacceptable hazards to human health and/or the environment, and will curtail or restrict their usage. The implementation of REACH will expand and deepen the fields of applied toxicology and exposure assessment by spurring activity and innovation in sampling and analysis, toxicology testing, exposure modeling, alternative toxicity testing, and risk assessment practices.

  11. Image Navigation and Registration Performance Assessment Evaluation Tools for GOES-R ABI and GLM

    NASA Technical Reports Server (NTRS)

    Houchin, Scott; Porter, Brian; Graybill, Justin; Slingerland, Philip

    2017-01-01

    The GOES-R Flight Project has developed an Image Navigation and Registration (INR) Performance Assessment Tool Set (IPATS) for measuring Advanced Baseline Imager (ABI) and Geostationary Lightning Mapper (GLM) INR performance metrics in the post-launch period for performance evaluation and long term monitoring. IPATS utilizes a modular algorithmic design to allow user selection of data processing sequences optimized for generation of each INR metric. This novel modular approach minimizes duplication of common processing elements, thereby maximizing code efficiency and speed. Fast processing is essential given the large number of sub-image registrations required to generate INR metrics for the many images produced over a 24 hour evaluation period. This paper describes the software design and implementation of IPATS and provides preliminary test results.

  12. Techniques for noise removal and registration of TIMS data

    USGS Publications Warehouse

    Hummer-Miller, S.

    1990-01-01

    Extracting subtle differences from highly correlated thermal infrared aircraft data is possible with appropriate noise filters, constructed and applied in the spatial frequency domain. This paper discusses a heuristic approach to designing noise filters for removing high- and low-spatial frequency striping and banding. Techniques for registering thermal infrared aircraft data to a topographic base using Thematic Mapper data are presented. The noise removal and registration techniques are applied to TIMS thermal infrared aircraft data. -Author

  13. Multi-modality image registration for effective thermographic fever screening

    NASA Astrophysics Data System (ADS)

    Dwith, C. Y. N.; Ghassemi, Pejhman; Pfefer, Joshua; Casamento, Jon; Wang, Quanzeng

    2017-02-01

    Fever screening based on infrared thermographs (IRTs) is a viable mass screening approach during infectious disease pandemics, such as Ebola and Severe Acute Respiratory Syndrome (SARS), for temperature monitoring in public places like hospitals and airports. IRTs have been found to be powerful, quick and non-invasive methods for detecting elevated temperatures. Moreover, regions medially adjacent to the inner canthi (called the canthi regions in this paper) are preferred sites for fever screening. Accurate localization of the canthi regions can be achieved through multi-modality registration of infrared (IR) and white-light images. Here we propose a registration method through a coarse-fine registration strategy using different registration models based on landmarks and edge detection on eye contours. We have evaluated the registration accuracy to be within +/- 2.7 mm, which enables accurate localization of the canthi regions.

  14. 76 FR 7194 - California State Nonroad Engine Pollution Control Standards; Request for Authorization of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-02-09

    ... Standards; Authorization of State Standards for 1996 and later New Diesel Cycle Engines 175 Horsepower and... ENVIRONMENTAL PROTECTION AGENCY [FRL-9264-3] California State Nonroad Engine Pollution Control... program that allows for the registration of nonroad engines and equipment units that operate at multiple...

  15. 37 CFR 2.17 - Recognition for representation.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ..., registrant, or party (e.g., a corporate officer or general partner of a partnership). In the case of joint..., DEPARTMENT OF COMMERCE RULES OF PRACTICE IN TRADEMARK CASES Representation by Attorneys Or Other Authorized Persons § 2.17 Recognition for representation. (a) Authority to practice in trademark cases. Only an...

  16. 31 CFR 321.7 - Authorized cash payments.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... registration on the front of the security, or by a person authorized or empowered to act for a corporate legal... securities, the governing regulations, and the provisions of this part, and any instructions issued in... this section, the securities must be presented by an individual whose name is inscribed on the...

  17. Closed-Form Jensen-Renyi Divergence for Mixture of Gaussians and Applications to Group-Wise Shape Registration*

    PubMed Central

    Wang, Fei; Syeda-Mahmood, Tanveer; Vemuri, Baba C.; Beymer, David; Rangarajan, Anand

    2010-01-01

    In this paper, we propose a generalized group-wise non-rigid registration strategy for multiple unlabeled point-sets of unequal cardinality, with no bias toward any of the given point-sets. To quantify the divergence between the probability distributions – specifically Mixture of Gaussians – estimated from the given point sets, we use a recently developed information-theoretic measure called Jensen-Renyi (JR) divergence. We evaluate a closed-form JR divergence between multiple probabilistic representations for the general case where the mixture models differ in variance and the number of components. We derive the analytic gradient of the divergence measure with respect to the non-rigid registration parameters, and apply it to numerical optimization of the group-wise registration, leading to a computationally efficient and accurate algorithm. We validate our approach on synthetic data, and evaluate it on 3D cardiac shapes. PMID:20426043

  18. Closed-form Jensen-Renyi divergence for mixture of Gaussians and applications to group-wise shape registration.

    PubMed

    Wang, Fei; Syeda-Mahmood, Tanveer; Vemuri, Baba C; Beymer, David; Rangarajan, Anand

    2009-01-01

    In this paper, we propose a generalized group-wise non-rigid registration strategy for multiple unlabeled point-sets of unequal cardinality, with no bias toward any of the given point-sets. To quantify the divergence between the probability distributions--specifically Mixture of Gaussians--estimated from the given point sets, we use a recently developed information-theoretic measure called Jensen-Renyi (JR) divergence. We evaluate a closed-form JR divergence between multiple probabilistic representations for the general case where the mixture models differ in variance and the number of components. We derive the analytic gradient of the divergence measure with respect to the non-rigid registration parameters, and apply it to numerical optimization of the group-wise registration, leading to a computationally efficient and accurate algorithm. We validate our approach on synthetic data, and evaluate it on 3D cardiac shapes.

  19. Automatic lung nodule matching for the follow-up in temporal chest CT scans

    NASA Astrophysics Data System (ADS)

    Hong, Helen; Lee, Jeongjin; Shin, Yeong Gil

    2006-03-01

    We propose a fast and robust registration method for matching lung nodules of temporal chest CT scans. Our method is composed of four stages. First, the lungs are extracted from chest CT scans by the automatic segmentation method. Second, the gross translational mismatch is corrected by the optimal cube registration. This initial registration does not require extracting any anatomical landmarks. Third, initial alignment is step by step refined by the iterative surface registration. To evaluate the distance measure between surface boundary points, a 3D distance map is generated by the narrow-band distance propagation, which drives fast and robust convergence to the optimal location. Fourth, nodule correspondences are established by the pairs with the smallest Euclidean distances. The results of pulmonary nodule alignment of twenty patients are reported on a per-center-of mass point basis using the average Euclidean distance (AED) error between corresponding nodules of initial and follow-up scans. The average AED error of twenty patients is significantly reduced to 4.7mm from 30.0mm by our registration. Experimental results show that our registration method aligns the lung nodules much faster than the conventional ones using a distance measure. Accurate and fast result of our method would be more useful for the radiologist's evaluation of pulmonary nodules on chest CT scans.

  20. Robust registration of sparsely sectioned histology to ex-vivo MRI of temporal lobe resections

    NASA Astrophysics Data System (ADS)

    Goubran, Maged; Khan, Ali R.; Crukley, Cathie; Buchanan, Susan; Santyr, Brendan; deRibaupierre, Sandrine; Peters, Terry M.

    2012-02-01

    Surgical resection of epileptic foci is a typical treatment for drug-resistant epilepsy, however, accurate preoperative localization is challenging and often requires invasive sub-dural or intra-cranial electrode placement. The presence of cellular abnormalities in the resected tissue can be used to validate the effectiveness of multispectralMagnetic Resonance Imaging (MRI) in pre-operative foci localization and surgical planning. If successful, these techniques can lead to improved surgical outcomes and less invasive procedures. Towards this goal, a novel pipeline is presented here for post-operative imaging of temporal lobe specimens involving MRI and digital histology, and present and evaluate methods for bringing these images into spatial correspondence. The sparsely-sectioned histology images of resected tissue represents a challenge for 3D reconstruction which we address with a combined 3D and 2D rigid registration algorithm that alternates between slice-based and volume-based registration with the ex-vivo MRI. We also evaluate four methods for non-rigid within-plane registration using both images and fiducials, with the top performing method resulting in a target registration error of 0.87 mm. This work allows for the spatially-local comparison of histology with post-operative MRI and paves the way for eventual registration with pre-operative MRI images.

  1. Few candidate termiticides are left in the pipeline, according to the 2011 USDA-FS termiticide report

    Treesearch

    Terry Wagner; Thomas Shelton; Chris Peterson

    2012-01-01

    Candidate termiticides typically undergo a five-year evaluation at four field sites before the U.S. Environmental Protection Agency (EPA) considers them for registration. The tests are conducted by the U.S. Department of Agriculture Forest Service (USDA-FS), which has a long history of evaluating termiticides for federal and state registration. In 2011, the USDA-FS...

  2. Cost-effective surgical registration using consumer depth cameras

    NASA Astrophysics Data System (ADS)

    Potter, Michael; Yaniv, Ziv

    2016-03-01

    The high costs associated with technological innovation have been previously identified as both a major contributor to the rise of health care expenses, and as a limitation for widespread adoption of new technologies. In this work we evaluate the use of two consumer grade depth cameras, the Microsoft Kinect v1 and 3DSystems Sense, as a means for acquiring point clouds for registration. These devices have the potential to replace professional grade laser range scanning devices in medical interventions that do not require sub-millimetric registration accuracy, and may do so at a significantly reduced cost. To facilitate the use of these devices we have developed a near real-time (1-4 sec/frame) rigid registration framework combining several alignment heuristics with the Iterative Closest Point (ICP) algorithm. Using nearest neighbor registration error as our evaluation criterion we found the optimal scanning distances for the Sense and Kinect to be 50-60cm and 70-80cm respectively. When imaging a skull phantom at these distances, RMS error values of 1.35mm and 1.14mm were obtained. The registration framework was then evaluated using cranial MR scans of two subjects. For the first subject, the RMS error using the Sense was 1.28 +/- 0.01 mm. Using the Kinect this error was 1.24 +/- 0.03 mm. For the second subject, whose MR scan was significantly corrupted by metal implants, the errors increased to 1.44 +/- 0.03 mm and 1.74 +/- 0.06 mm but the system nonetheless performed within acceptable bounds.

  3. Evaluation of non-rigid registration parameters for atlas-based segmentation of CT images of human cochlea

    NASA Astrophysics Data System (ADS)

    Elfarnawany, Mai; Alam, S. Riyahi; Agrawal, Sumit K.; Ladak, Hanif M.

    2017-02-01

    Cochlear implant surgery is a hearing restoration procedure for patients with profound hearing loss. In this surgery, an electrode is inserted into the cochlea to stimulate the auditory nerve and restore the patient's hearing. Clinical computed tomography (CT) images are used for planning and evaluation of electrode placement, but their low resolution limits the visualization of internal cochlear structures. Therefore, high resolution micro-CT images are used to develop atlas-based segmentation methods to extract these nonvisible anatomical features in clinical CT images. Accurate registration of the high and low resolution CT images is a prerequisite for reliable atlas-based segmentation. In this study, we evaluate and compare different non-rigid B-spline registration parameters using micro-CT and clinical CT images of five cadaveric human cochleae. The varying registration parameters are cost function (normalized correlation (NC), mutual information and mean square error), interpolation method (linear, windowed-sinc and B-spline) and sampling percentage (1%, 10% and 100%). We compare the registration results visually and quantitatively using the Dice similarity coefficient (DSC), Hausdorff distance (HD) and absolute percentage error in cochlear volume. Using MI or MSE cost functions and linear or windowed-sinc interpolation resulted in visually undesirable deformation of internal cochlear structures. Quantitatively, the transforms using 100% sampling percentage yielded the highest DSC and smallest HD (0.828+/-0.021 and 0.25+/-0.09mm respectively). Therefore, B-spline registration with cost function: NC, interpolation: B-spline and sampling percentage: moments 100% can be the foundation of developing an optimized atlas-based segmentation algorithm of intracochlear structures in clinical CT images.

  4. Validation of non-rigid point-set registration methods using a porcine bladder pelvic phantom

    NASA Astrophysics Data System (ADS)

    Zakariaee, Roja; Hamarneh, Ghassan; Brown, Colin J.; Spadinger, Ingrid

    2016-01-01

    The problem of accurate dose accumulation in fractionated radiotherapy treatment for highly deformable organs, such as bladder, has garnered increasing interest over the past few years. However, more research is required in order to find a robust and efficient solution and to increase the accuracy over the current methods. The purpose of this study was to evaluate the feasibility and accuracy of utilizing non-rigid (affine or deformable) point-set registration in accumulating dose in bladder of different sizes and shapes. A pelvic phantom was built to house an ex vivo porcine bladder with fiducial landmarks adhered onto its surface. Four different volume fillings of the bladder were used (90, 180, 360 and 480 cc). The performance of MATLAB implementations of five different methods were compared, in aligning the bladder contour point-sets. The approaches evaluated were coherent point drift (CPD), gaussian mixture model, shape context, thin-plate spline robust point matching (TPS-RPM) and finite iterative closest point (ICP-finite). The evaluation metrics included registration runtime, target registration error (TRE), root-mean-square error (RMS) and Hausdorff distance (HD). The reference (source) dataset was alternated through all four points-sets, in order to study the effect of reference volume on the registration outcomes. While all deformable algorithms provided reasonable registration results, CPD provided the best TRE values (6.4 mm), and TPS-RPM yielded the best mean RMS and HD values (1.4 and 6.8 mm, respectively). ICP-finite was the fastest technique and TPS-RPM, the slowest.

  5. TH-EF-BRA-03: Assessment of Data-Driven Respiratory Motion-Compensation Methods for 4D-CBCT Image Registration and Reconstruction Using Clinical Datasets

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Riblett, MJ; Weiss, E; Hugo, GD

    Purpose: To evaluate the performance of a 4D-CBCT registration and reconstruction method that corrects for respiratory motion and enhances image quality under clinically relevant conditions. Methods: Building on previous work, which tested feasibility of a motion-compensation workflow using image datasets superior to clinical acquisitions, this study assesses workflow performance under clinical conditions in terms of image quality improvement. Evaluated workflows utilized a combination of groupwise deformable image registration (DIR) and image reconstruction. Four-dimensional cone beam CT (4D-CBCT) FDK reconstructions were registered to either mean or respiratory phase reference frame images to model respiratory motion. The resulting 4D transformation was usedmore » to deform projection data during the FDK backprojection operation to create a motion-compensated reconstruction. To simulate clinically realistic conditions, superior quality projection datasets were sampled using a phase-binned striding method. Tissue interface sharpness (TIS) was defined as the slope of a sigmoid curve fit to the lung-diaphragm boundary or to the carina tissue-airway boundary when no diaphragm was discernable. Image quality improvement was assessed in 19 clinical cases by evaluating mitigation of view-aliasing artifacts, tissue interface sharpness recovery, and noise reduction. Results: For clinical datasets, evaluated average TIS recovery relative to base 4D-CBCT reconstructions was observed to be 87% using fixed-frame registration alone; 87% using fixed-frame with motion-compensated reconstruction; 92% using mean-frame registration alone; and 90% using mean-frame with motion-compensated reconstruction. Soft tissue noise was reduced on average by 43% and 44% for the fixed-frame registration and registration with motion-compensation methods, respectively, and by 40% and 42% for the corresponding mean-frame methods. Considerable reductions in view aliasing artifacts were observed for each method. Conclusion: Data-driven groupwise registration and motion-compensated reconstruction have the potential to improve the quality of 4D-CBCT images acquired under clinical conditions. For clinical image datasets, the addition of motion compensation after groupwise registration visibly reduced artifact impact. This work was supported by the National Cancer Institute of the National Institutes of Health under Award Number R01CA166119. Hugo and Weiss hold a research agreement with Philips Healthcare and license agreement with Varian Medical Systems. Weiss receives royalties from UpToDate. Christensen receives funds from Roger Koch to support research.« less

  6. Influence of image registration on apparent diffusion coefficient images computed from free-breathing diffusion MR images of the abdomen.

    PubMed

    Guyader, Jean-Marie; Bernardin, Livia; Douglas, Naomi H M; Poot, Dirk H J; Niessen, Wiro J; Klein, Stefan

    2015-08-01

    To evaluate the influence of image registration on apparent diffusion coefficient (ADC) images obtained from abdominal free-breathing diffusion-weighted MR images (DW-MRIs). A comprehensive pipeline based on automatic three-dimensional nonrigid image registrations is developed to compensate for misalignments in DW-MRI datasets obtained from five healthy subjects scanned twice. Motion is corrected both within each image and between images in a time series. ADC distributions are compared with and without registration in two abdominal volumes of interest (VOIs). The effects of interpolations and Gaussian blurring as alternative strategies to reduce motion artifacts are also investigated. Among the four considered scenarios (no processing, interpolation, blurring and registration), registration yields the best alignment scores. Median ADCs vary according to the chosen scenario: for the considered datasets, ADCs obtained without processing are 30% higher than with registration. Registration improves voxelwise reproducibility at least by a factor of 2 and decreases uncertainty (Fréchet-Cramér-Rao lower bound). Registration provides similar improvements in reproducibility and uncertainty as acquiring four times more data. Patient motion during image acquisition leads to misaligned DW-MRIs and inaccurate ADCs, which can be addressed using automatic registration. © 2014 Wiley Periodicals, Inc.

  7. Gaussian Process Interpolation for Uncertainty Estimation in Image Registration

    PubMed Central

    Wachinger, Christian; Golland, Polina; Reuter, Martin; Wells, William

    2014-01-01

    Intensity-based image registration requires resampling images on a common grid to evaluate the similarity function. The uncertainty of interpolation varies across the image, depending on the location of resampled points relative to the base grid. We propose to perform Bayesian inference with Gaussian processes, where the covariance matrix of the Gaussian process posterior distribution estimates the uncertainty in interpolation. The Gaussian process replaces a single image with a distribution over images that we integrate into a generative model for registration. Marginalization over resampled images leads to a new similarity measure that includes the uncertainty of the interpolation. We demonstrate that our approach increases the registration accuracy and propose an efficient approximation scheme that enables seamless integration with existing registration methods. PMID:25333127

  8. A prospective comparison between auto-registration and manual registration of real-time ultrasound with MR images for percutaneous ablation or biopsy of hepatic lesions.

    PubMed

    Cha, Dong Ik; Lee, Min Woo; Song, Kyoung Doo; Oh, Young-Taek; Jeong, Ja-Yeon; Chang, Jung-Woo; Ryu, Jiwon; Lee, Kyong Joon; Kim, Jaeil; Bang, Won-Chul; Shin, Dong Kuk; Choi, Sung Jin; Koh, Dalkwon; Seo, Bong Koo; Kim, Kyunga

    2017-06-01

    To compare the accuracy and required time for image fusion of real-time ultrasound (US) with pre-procedural magnetic resonance (MR) images between positioning auto-registration and manual registration for percutaneous radiofrequency ablation or biopsy of hepatic lesions. This prospective study was approved by the institutional review board, and all patients gave written informed consent. Twenty-two patients (male/female, n = 18/n = 4; age, 61.0 ± 7.7 years) who were referred for planning US to assess the feasibility of radiofrequency ablation (n = 21) or biopsy (n = 1) for focal hepatic lesions were included. One experienced radiologist performed the two types of image fusion methods in each patient. The performance of auto-registration and manual registration was evaluated. The accuracy of the two methods, based on measuring registration error, and the time required for image fusion for both methods were recorded using in-house software and respectively compared using the Wilcoxon signed rank test. Image fusion was successful in all patients. The registration error was not significantly different between the two methods (auto-registration: median, 3.75 mm; range, 1.0-15.8 mm vs. manual registration: median, 2.95 mm; range, 1.2-12.5 mm, p = 0.242). The time required for image fusion was significantly shorter with auto-registration than with manual registration (median, 28.5 s; range, 18-47 s, vs. median, 36.5 s; range, 14-105 s, p = 0.026). Positioning auto-registration showed promising results compared with manual registration, with similar accuracy and even shorter registration time.

  9. New Protocol for Skin Landmark Registration in Image-Guided Neurosurgery: Technical Note.

    PubMed

    Gerard, Ian J; Hall, Jeffery A; Mok, Kelvin; Collins, D Louis

    2015-09-01

    Newer versions of the commercial Medtronic StealthStation allow the use of only 8 landmark pairs for patient-to-image registration as opposed to 9 landmarks in older systems. The choice of which landmark pair to drop in these newer systems can have an effect on the quality of the patient-to-image registration. To investigate 4 landmark registration protocols based on 8 landmark pairs and compare the resulting registration accuracy with a 9-landmark protocol. Four different protocols were tested on both phantoms and patients. Two of the protocols involved using 4 ear landmarks and 4 facial landmarks and the other 2 involved using 3 ear landmarks and 5 facial landmarks. Both the fiducial registration error and target registration error were evaluated for each of the different protocols to determine any difference between them and the 9-landmark protocol. No difference in fiducial registration error was found between any of the 8-landmark protocols and the 9-landmark protocol. A significant decrease (P < .05) in target registration error was found when using a protocol based on 4 ear landmarks and 4 facial landmarks compared with the other protocols based on 3 ear landmarks. When using 8 landmarks to perform the patient-to-image registration, the protocol using 4 ear landmarks and 4 facial landmarks greatly outperformed the other 8-landmark protocols and 9-landmark protocol, resulting in the lowest target registration error.

  10. MRI-based treatment planning with pseudo CT generated through atlas registration.

    PubMed

    Uh, Jinsoo; Merchant, Thomas E; Li, Yimei; Li, Xingyu; Hua, Chiaho

    2014-05-01

    To evaluate the feasibility and accuracy of magnetic resonance imaging (MRI)-based treatment planning using pseudo CTs generated through atlas registration. A pseudo CT, providing electron density information for dose calculation, was generated by deforming atlas CT images previously acquired on other patients. The authors tested 4 schemes of synthesizing a pseudo CT from single or multiple deformed atlas images: use of a single arbitrarily selected atlas, arithmetic mean process using 6 atlases, and pattern recognition with Gaussian process (PRGP) using 6 or 12 atlases. The required deformation for atlas CT images was derived from a nonlinear registration of conjugated atlas MR images to that of the patient of interest. The contrasts of atlas MR images were adjusted by histogram matching to reduce the effect of different sets of acquisition parameters. For comparison, the authors also tested a simple scheme assigning the Hounsfield unit of water to the entire patient volume. All pseudo CT generating schemes were applied to 14 patients with common pediatric brain tumors. The image similarity of real patient-specific CT and pseudo CTs constructed by different schemes was compared. Differences in computation times were also calculated. The real CT in the treatment planning system was replaced with the pseudo CT, and the dose distribution was recalculated to determine the difference. The atlas approach generally performed better than assigning a bulk CT number to the entire patient volume. Comparing atlas-based schemes, those using multiple atlases outperformed the single atlas scheme. For multiple atlas schemes, the pseudo CTs were similar to the real CTs (correlation coefficient, 0.787-0.819). The calculated dose distribution was in close agreement with the original dose. Nearly the entire patient volume (98.3%-98.7%) satisfied the criteria of chi-evaluation (<2% maximum dose and 2 mm range). The dose to 95% of the volume and the percentage of volume receiving at least 95% of the prescription dose in the planning target volume differed from the original values by less than 2% of the prescription dose (root-mean-square, RMS < 1%). The PRGP scheme did not perform better than the arithmetic mean process with the same number of atlases. Increasing the number of atlases from 6 to 12 often resulted in improvements, but statistical significance was not always found. MRI-based treatment planning with pseudo CTs generated through atlas registration is feasible for pediatric brain tumor patients. The doses calculated from pseudo CTs agreed well with those from real CTs, showing dosimetric accuracy within 2% for the PTV when multiple atlases were used. The arithmetic mean process may be a reasonable choice over PRGP for the synthesis scheme considering performance and computational costs.

  11. MRI-based treatment planning with pseudo CT generated through atlas registration

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Uh, Jinsoo, E-mail: jinsoo.uh@stjude.org; Merchant, Thomas E.; Hua, Chiaho

    2014-05-15

    Purpose: To evaluate the feasibility and accuracy of magnetic resonance imaging (MRI)-based treatment planning using pseudo CTs generated through atlas registration. Methods: A pseudo CT, providing electron density information for dose calculation, was generated by deforming atlas CT images previously acquired on other patients. The authors tested 4 schemes of synthesizing a pseudo CT from single or multiple deformed atlas images: use of a single arbitrarily selected atlas, arithmetic mean process using 6 atlases, and pattern recognition with Gaussian process (PRGP) using 6 or 12 atlases. The required deformation for atlas CT images was derived from a nonlinear registration ofmore » conjugated atlas MR images to that of the patient of interest. The contrasts of atlas MR images were adjusted by histogram matching to reduce the effect of different sets of acquisition parameters. For comparison, the authors also tested a simple scheme assigning the Hounsfield unit of water to the entire patient volume. All pseudo CT generating schemes were applied to 14 patients with common pediatric brain tumors. The image similarity of real patient-specific CT and pseudo CTs constructed by different schemes was compared. Differences in computation times were also calculated. The real CT in the treatment planning system was replaced with the pseudo CT, and the dose distribution was recalculated to determine the difference. Results: The atlas approach generally performed better than assigning a bulk CT number to the entire patient volume. Comparing atlas-based schemes, those using multiple atlases outperformed the single atlas scheme. For multiple atlas schemes, the pseudo CTs were similar to the real CTs (correlation coefficient, 0.787–0.819). The calculated dose distribution was in close agreement with the original dose. Nearly the entire patient volume (98.3%–98.7%) satisfied the criteria of chi-evaluation (<2% maximum dose and 2 mm range). The dose to 95% of the volume and the percentage of volume receiving at least 95% of the prescription dose in the planning target volume differed from the original values by less than 2% of the prescription dose (root-mean-square, RMS < 1%). The PRGP scheme did not perform better than the arithmetic mean process with the same number of atlases. Increasing the number of atlases from 6 to 12 often resulted in improvements, but statistical significance was not always found. Conclusions: MRI-based treatment planning with pseudo CTs generated through atlas registration is feasible for pediatric brain tumor patients. The doses calculated from pseudo CTs agreed well with those from real CTs, showing dosimetric accuracy within 2% for the PTV when multiple atlases were used. The arithmetic mean process may be a reasonable choice over PRGP for the synthesis scheme considering performance and computational costs.« less

  12. MRI-based treatment planning with pseudo CT generated through atlas registration

    PubMed Central

    Uh, Jinsoo; Merchant, Thomas E.; Li, Yimei; Li, Xingyu; Hua, Chiaho

    2014-01-01

    Purpose: To evaluate the feasibility and accuracy of magnetic resonance imaging (MRI)-based treatment planning using pseudo CTs generated through atlas registration. Methods: A pseudo CT, providing electron density information for dose calculation, was generated by deforming atlas CT images previously acquired on other patients. The authors tested 4 schemes of synthesizing a pseudo CT from single or multiple deformed atlas images: use of a single arbitrarily selected atlas, arithmetic mean process using 6 atlases, and pattern recognition with Gaussian process (PRGP) using 6 or 12 atlases. The required deformation for atlas CT images was derived from a nonlinear registration of conjugated atlas MR images to that of the patient of interest. The contrasts of atlas MR images were adjusted by histogram matching to reduce the effect of different sets of acquisition parameters. For comparison, the authors also tested a simple scheme assigning the Hounsfield unit of water to the entire patient volume. All pseudo CT generating schemes were applied to 14 patients with common pediatric brain tumors. The image similarity of real patient-specific CT and pseudo CTs constructed by different schemes was compared. Differences in computation times were also calculated. The real CT in the treatment planning system was replaced with the pseudo CT, and the dose distribution was recalculated to determine the difference. Results: The atlas approach generally performed better than assigning a bulk CT number to the entire patient volume. Comparing atlas-based schemes, those using multiple atlases outperformed the single atlas scheme. For multiple atlas schemes, the pseudo CTs were similar to the real CTs (correlation coefficient, 0.787–0.819). The calculated dose distribution was in close agreement with the original dose. Nearly the entire patient volume (98.3%–98.7%) satisfied the criteria of chi-evaluation (<2% maximum dose and 2 mm range). The dose to 95% of the volume and the percentage of volume receiving at least 95% of the prescription dose in the planning target volume differed from the original values by less than 2% of the prescription dose (root-mean-square, RMS < 1%). The PRGP scheme did not perform better than the arithmetic mean process with the same number of atlases. Increasing the number of atlases from 6 to 12 often resulted in improvements, but statistical significance was not always found. Conclusions: MRI-based treatment planning with pseudo CTs generated through atlas registration is feasible for pediatric brain tumor patients. The doses calculated from pseudo CTs agreed well with those from real CTs, showing dosimetric accuracy within 2% for the PTV when multiple atlases were used. The arithmetic mean process may be a reasonable choice over PRGP for the synthesis scheme considering performance and computational costs. PMID:24784377

  13. Comparative Analysis of Emergency Response Operations: Haiti Earthquake in January 2010 and Pakistan’s Flood in 2010

    DTIC Science & Technology

    2011-09-01

    Earthquake, Pakistan, Flood, Emergency Response Operations, International Community, HA/DR, United Nations , FRC, NDMA , ICT 16. PRICE CODE 17. SECURITY...Registration Authority NATO North Atlantic Treaty Organization NDMA National Disaster and Management Authority NDMC National Disaster Management...complicates relief efforts. 6 NDMA Pakistan, “Pakistan Floods-Summary of Damages,” No Author. Accessed 24

  14. Potential accuracy of translation estimation between radar and optical images

    NASA Astrophysics Data System (ADS)

    Uss, M.; Vozel, B.; Lukin, V.; Chehdi, K.

    2015-10-01

    This paper investigates the potential accuracy achievable for optical to radar image registration by area-based approach. The analysis is carried out mainly based on the Cramér-Rao Lower Bound (CRLB) on translation estimation accuracy previously proposed by the authors and called CRLBfBm. This bound is now modified to take into account radar image speckle noise properties: spatial correlation and signal-dependency. The newly derived theoretical bound is fed with noise and texture parameters estimated for the co-registered pair of optical Landsat 8 and radar SIR-C images. It is found that difficulty of optical to radar image registration stems more from speckle noise influence than from dissimilarity of the considered kinds of images. At finer scales (and higher speckle noise level), probability of finding control fragments (CF) suitable for registration is low (1% or less) but overall number of such fragments is high thanks to image size. Conversely, at the coarse scale, where speckle noise level is reduced, probability of finding CFs suitable for registration can be as high as 40%, but overall number of such CFs is lower. Thus, the study confirms and supports area-based multiresolution approach for optical to radar registration where coarse scales are used for fast registration "lock" and finer scales for reaching higher registration accuracy. The CRLBfBm is found inaccurate for the main scale due to intensive speckle noise influence. For other scales, the validity of the CRLBfBm bound is confirmed by calculating statistical efficiency of area-based registration method based on normalized correlation coefficient (NCC) measure that takes high values of about 25%.

  15. Registration-based segmentation with articulated model from multipostural magnetic resonance images for hand bone motion animation.

    PubMed

    Chen, Hsin-Chen; Jou, I-Ming; Wang, Chien-Kuo; Su, Fong-Chin; Sun, Yung-Nien

    2010-06-01

    The quantitative measurements of hand bones, including volume, surface, orientation, and position are essential in investigating hand kinematics. Moreover, within the measurement stage, bone segmentation is the most important step due to its certain influences on measuring accuracy. Since hand bones are small and tubular in shape, magnetic resonance (MR) imaging is prone to artifacts such as nonuniform intensity and fuzzy boundaries. Thus, greater detail is required for improving segmentation accuracy. The authors then propose using a novel registration-based method on an articulated hand model to segment hand bones from multipostural MR images. The proposed method consists of the model construction and registration-based segmentation stages. Given a reference postural image, the first stage requires construction of a drivable reference model characterized by hand bone shapes, intensity patterns, and articulated joint mechanism. By applying the reference model to the second stage, the authors initially design a model-based registration pursuant to intensity distribution similarity, MR bone intensity properties, and constraints of model geometry to align the reference model to target bone regions of the given postural image. The authors then refine the resulting surface to improve the superimposition between the registered reference model and target bone boundaries. For each subject, given a reference postural image, the proposed method can automatically segment all hand bones from all other postural images. Compared to the ground truth from two experts, the resulting surface image had an average margin of error within 1 mm (mm) only. In addition, the proposed method showed good agreement on the overlap of bone segmentations by dice similarity coefficient and also demonstrated better segmentation results than conventional methods. The proposed registration-based segmentation method can successfully overcome drawbacks caused by inherent artifacts in MR images and obtain more accurate segmentation results automatically. Moreover, realistic hand motion animations can be generated based on the bone segmentation results. The proposed method is found helpful for understanding hand bone geometries in dynamic postures that can be used in simulating 3D hand motion through multipostural MR images.

  16. The Insight ToolKit image registration framework

    PubMed Central

    Avants, Brian B.; Tustison, Nicholas J.; Stauffer, Michael; Song, Gang; Wu, Baohua; Gee, James C.

    2014-01-01

    Publicly available scientific resources help establish evaluation standards, provide a platform for teaching and improve reproducibility. Version 4 of the Insight ToolKit (ITK4) seeks to establish new standards in publicly available image registration methodology. ITK4 makes several advances in comparison to previous versions of ITK. ITK4 supports both multivariate images and objective functions; it also unifies high-dimensional (deformation field) and low-dimensional (affine) transformations with metrics that are reusable across transform types and with composite transforms that allow arbitrary series of geometric mappings to be chained together seamlessly. Metrics and optimizers take advantage of multi-core resources, when available. Furthermore, ITK4 reduces the parameter optimization burden via principled heuristics that automatically set scaling across disparate parameter types (rotations vs. translations). A related approach also constrains steps sizes for gradient-based optimizers. The result is that tuning for different metrics and/or image pairs is rarely necessary allowing the researcher to more easily focus on design/comparison of registration strategies. In total, the ITK4 contribution is intended as a structure to support reproducible research practices, will provide a more extensive foundation against which to evaluate new work in image registration and also enable application level programmers a broad suite of tools on which to build. Finally, we contextualize this work with a reference registration evaluation study with application to pediatric brain labeling.1 PMID:24817849

  17. Reproducibility measurements of three methods for calculating in vivo MR-based knee kinematics.

    PubMed

    Lansdown, Drew A; Zaid, Musa; Pedoia, Valentina; Subburaj, Karupppasamy; Souza, Richard; Benjamin, C; Li, Xiaojuan

    2015-08-01

    To describe three quantification methods for magnetic resonance imaging (MRI)-based knee kinematic evaluation and to report on the reproducibility of these algorithms. T2 -weighted, fast-spin echo images were obtained of the bilateral knees in six healthy volunteers. Scans were repeated for each knee after repositioning to evaluate protocol reproducibility. Semiautomatic segmentation defined regions of interest for the tibia and femur. The posterior femoral condyles and diaphyseal axes were defined using the previously defined tibia and femur. All segmentation was performed twice to evaluate segmentation reliability. Anterior tibial translation (ATT) and internal tibial rotation (ITR) were calculated using three methods: a tibial-based registration system, a combined tibiofemoral-based registration method with all manual segmentation, and a combined tibiofemoral-based registration method with automatic definition of condyles and axes. Intraclass correlation coefficients and standard deviations across multiple measures were determined. Reproducibility of segmentation was excellent (ATT = 0.98; ITR = 0.99) for both combined methods. ATT and ITR measurements were also reproducible across multiple scans in the combined registration measurements with manual (ATT = 0.94; ITR = 0.94) or automatic (ATT = 0.95; ITR = 0.94) condyles and axes. The combined tibiofemoral registration with automatic definition of the posterior femoral condyle and diaphyseal axes allows for improved knee kinematics quantification with excellent in vivo reproducibility. © 2014 Wiley Periodicals, Inc.

  18. Real-time three dimensional CT and MRI to guide interventions for congenital heart disease and acquired pulmonary vein stenosis.

    PubMed

    Suntharos, Patcharapong; Setser, Randolph M; Bradley-Skelton, Sharon; Prieto, Lourdes R

    2017-10-01

    To validate the feasibility and spatial accuracy of pre-procedural 3D images to 3D rotational fluoroscopy registration to guide interventional procedures in patients with congenital heart disease and acquired pulmonary vein stenosis. Cardiac interventions in patients with congenital and structural heart disease require complex catheter manipulation. Current technology allows registration of the anatomy obtained from 3D CT and/or MRI to be overlaid onto fluoroscopy. Thirty patients scheduled for interventional procedures from 12/2012 to 8/2015 were prospectively recruited. A C-arm CT using a biplane C-arm system (Artis zee, VC14H, Siemens Healthcare) was acquired to enable 3D3D registration with pre-procedural images. Following successful image fusion, the anatomic landmarks marked in pre-procedural images were overlaid on live fluoroscopy. The accuracy of image registration was determined by measuring the distance between overlay markers and a reference point in the image. The clinical utility of the registration was evaluated as either "High", "Medium" or "None". Seventeen patients with congenital heart disease and 13 with acquired pulmonary vein stenosis were enrolled. Accuracy and benefit of registration were not evaluated in two patients due to suboptimal images. The distance between the marker and the actual anatomical location was 0-2 mm in 18 (64%), 2-4 mm in 3 (11%) and >4 mm in 7 (25%) patients. 3D3D registration was highly beneficial in 18 (64%), intermediate in 3 (11%), and not beneficial in 7 (25%) patients. 3D3D registration can facilitate complex congenital and structural interventions. It may reduce procedure time, radiation and contrast dose.

  19. A fast rigid-registration method of inferior limb X-ray image and 3D CT images for TKA surgery

    NASA Astrophysics Data System (ADS)

    Ito, Fumihito; O. D. A, Prima; Uwano, Ikuko; Ito, Kenzo

    2010-03-01

    In this paper, we propose a fast rigid-registration method of inferior limb X-ray films (two-dimensional Computed Radiography (CR) images) and three-dimensional Computed Tomography (CT) images for Total Knee Arthroplasty (TKA) surgery planning. The position of the each bone, such as femur and tibia (shin bone), in X-ray film and 3D CT images is slightly different, and we must pay attention how to use the two different images, since X-ray film image is captured in the standing position, and 3D CT is captured in decubitus (face up) position, respectively. Though the conventional registration mainly uses cross-correlation function between two images,and utilizes optimization techniques, it takes enormous calculation time and it is difficult to use it in interactive operations. In order to solve these problems, we calculate the center line (bone axis) of femur and tibia (shin bone) automatically, and we use them as initial positions for the registration. We evaluate our registration method by using three patient's image data, and we compare our proposed method and a conventional registration, which uses down-hill simplex algorithm. The down-hill simplex method is an optimization algorithm that requires only function evaluations, and doesn't need the calculation of derivatives. Our registration method is more effective than the downhill simplex method in computational time and the stable convergence. We have developed the implant simulation system on a personal computer, in order to support the surgeon in a preoperative planning of TKA. Our registration method is implemented in the simulation system, and user can manipulate 2D/3D translucent templates of implant components on X-ray film and 3D CT images.

  20. 31 CFR 321.7 - Authorized cash payments.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... registration on the front of the security, or by a person authorized or empowered to act for a corporate legal... appearing on the securities, the governing regulations, and the provisions of this part, and any...) through (d), and (f) of this section, the securities must be presented by an individual whose name is...

  1. 31 CFR 321.7 - Authorized cash payments.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... registration on the front of the security, or by a person authorized or empowered to act for a corporate legal... appearing on the securities, the governing regulations, and the provisions of this part, and any...) through (d), and (f) of this section, the securities must be presented by an individual whose name is...

  2. 31 CFR 321.7 - Authorized cash payments.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... registration on the front of the security, or by a person authorized or empowered to act for a corporate legal... appearing on the securities, the governing regulations, and the provisions of this part, and any...) through (d), and (f) of this section, the securities must be presented by an individual whose name is...

  3. Performance Evaluation of MIND Demons Deformable Registration of MR and CT Images in Spinal Interventions

    PubMed Central

    Reaungamornrat, S.; De Silva, T.; Uneri, A.; Goerres, J.; Jacobson, M.; Ketcha, M.; Vogt, S.; Kleinszig, G.; Khanna, A. J.; Wolinsky, J.-P.; Prince, J. L.; Siewerdsen, J. H.

    2016-01-01

    Accurate intraoperative localization of target anatomy and adjacent nervous and vascular tissue is essential to safe, effective surgery, and multimodality deformable registration can be used to identify such anatomy by fusing preoperative CT or MR images with intraoperative images. A deformable image registration method has been developed to estimate viscoelastic diffeomorphisms between preoperative MR and intraoperative CT using modality-independent neighborhood descriptors (MIND) and a Huber metric for robust registration. The method, called MIND Demons, optimizes a constrained symmetric energy functional incorporating priors on smoothness, geodesics, and invertibility by alternating between Gauss-Newton optimization and Tikhonov regularization in a multiresolution scheme. Registration performance was evaluated for the MIND Demons method with a symmetric energy formulation in comparison to an asymmetric form, and sensitivity to anisotropic MR voxel-size was analyzed in phantom experiments emulating image-guided spine-surgery in comparison to a free-form deformation (FFD) method using local mutual information (LMI). Performance was validated in a clinical study involving 15 patients undergoing intervention of the cervical, thoracic, and lumbar spine. The target registration error (TRE) for the symmetric MIND Demons formulation [1.3 ± 0.8 mm (median ± interquartile)] outperformed the asymmetric form [3.6 ± 4.4 mm]. The method demonstrated fairly minor sensitivity to anisotropic MR voxel size, with median TRE ranging 1.3 – 2.9 mm for MR slice thickness ranging 0.9 – 9.9 mm, compared to TRE = 3.2 – 4.1 mm for LMI FFD over the same range. Evaluation in clinical data demonstrated sub-voxel TRE (< 2 mm) in all fifteen cases with realistic deformations that preserved topology with sub-voxel invertibility (0.001 mm) and positive-determinant spatial Jacobians. The approach therefore appears robust against realistic anisotropic resolution characteristics in MR and yields registration accuracy suitable to application in image-guided spine-surgery. PMID:27811396

  4. Performance evaluation of MIND demons deformable registration of MR and CT images in spinal interventions.

    PubMed

    Reaungamornrat, S; De Silva, T; Uneri, A; Goerres, J; Jacobson, M; Ketcha, M; Vogt, S; Kleinszig, G; Khanna, A J; Wolinsky, J-P; Prince, J L; Siewerdsen, J H

    2016-12-07

    Accurate intraoperative localization of target anatomy and adjacent nervous and vascular tissue is essential to safe, effective surgery, and multimodality deformable registration can be used to identify such anatomy by fusing preoperative CT or MR images with intraoperative images. A deformable image registration method has been developed to estimate viscoelastic diffeomorphisms between preoperative MR and intraoperative CT using modality-independent neighborhood descriptors (MIND) and a Huber metric for robust registration. The method, called MIND Demons, optimizes a constrained symmetric energy functional incorporating priors on smoothness, geodesics, and invertibility by alternating between Gauss-Newton optimization and Tikhonov regularization in a multiresolution scheme. Registration performance was evaluated for the MIND Demons method with a symmetric energy formulation in comparison to an asymmetric form, and sensitivity to anisotropic MR voxel-size was analyzed in phantom experiments emulating image-guided spine-surgery in comparison to a free-form deformation (FFD) method using local mutual information (LMI). Performance was validated in a clinical study involving 15 patients undergoing intervention of the cervical, thoracic, and lumbar spine. The target registration error (TRE) for the symmetric MIND Demons formulation (1.3  ±  0.8 mm (median  ±  interquartile)) outperformed the asymmetric form (3.6  ±  4.4 mm). The method demonstrated fairly minor sensitivity to anisotropic MR voxel size, with median TRE ranging 1.3-2.9 mm for MR slice thickness ranging 0.9-9.9 mm, compared to TRE  =  3.2-4.1 mm for LMI FFD over the same range. Evaluation in clinical data demonstrated sub-voxel TRE (<2 mm) in all fifteen cases with realistic deformations that preserved topology with sub-voxel invertibility (0.001 mm) and positive-determinant spatial Jacobians. The approach therefore appears robust against realistic anisotropic resolution characteristics in MR and yields registration accuracy suitable to application in image-guided spine-surgery.

  5. Performance evaluation of MIND demons deformable registration of MR and CT images in spinal interventions

    NASA Astrophysics Data System (ADS)

    Reaungamornrat, S.; De Silva, T.; Uneri, A.; Goerres, J.; Jacobson, M.; Ketcha, M.; Vogt, S.; Kleinszig, G.; Khanna, A. J.; Wolinsky, J.-P.; Prince, J. L.; Siewerdsen, J. H.

    2016-12-01

    Accurate intraoperative localization of target anatomy and adjacent nervous and vascular tissue is essential to safe, effective surgery, and multimodality deformable registration can be used to identify such anatomy by fusing preoperative CT or MR images with intraoperative images. A deformable image registration method has been developed to estimate viscoelastic diffeomorphisms between preoperative MR and intraoperative CT using modality-independent neighborhood descriptors (MIND) and a Huber metric for robust registration. The method, called MIND Demons, optimizes a constrained symmetric energy functional incorporating priors on smoothness, geodesics, and invertibility by alternating between Gauss-Newton optimization and Tikhonov regularization in a multiresolution scheme. Registration performance was evaluated for the MIND Demons method with a symmetric energy formulation in comparison to an asymmetric form, and sensitivity to anisotropic MR voxel-size was analyzed in phantom experiments emulating image-guided spine-surgery in comparison to a free-form deformation (FFD) method using local mutual information (LMI). Performance was validated in a clinical study involving 15 patients undergoing intervention of the cervical, thoracic, and lumbar spine. The target registration error (TRE) for the symmetric MIND Demons formulation (1.3  ±  0.8 mm (median  ±  interquartile)) outperformed the asymmetric form (3.6  ±  4.4 mm). The method demonstrated fairly minor sensitivity to anisotropic MR voxel size, with median TRE ranging 1.3-2.9 mm for MR slice thickness ranging 0.9-9.9 mm, compared to TRE  =  3.2-4.1 mm for LMI FFD over the same range. Evaluation in clinical data demonstrated sub-voxel TRE (<2 mm) in all fifteen cases with realistic deformations that preserved topology with sub-voxel invertibility (0.001 mm) and positive-determinant spatial Jacobians. The approach therefore appears robust against realistic anisotropic resolution characteristics in MR and yields registration accuracy suitable to application in image-guided spine-surgery.

  6. Non-rigid registration of serial dedicated breast CT, longitudinal dedicated breast CT and PET/CT images using the diffeomorphic demons method.

    PubMed

    Santos, Jonathan; Chaudhari, Abhijit J; Joshi, Anand A; Ferrero, Andrea; Yang, Kai; Boone, John M; Badawi, Ramsey D

    2014-09-01

    Dedicated breast CT and PET/CT scanners provide detailed 3D anatomical and functional imaging data sets and are currently being investigated for applications in breast cancer management such as diagnosis, monitoring response to therapy and radiation therapy planning. Our objective was to evaluate the performance of the diffeomorphic demons (DD) non-rigid image registration method to spatially align 3D serial (pre- and post-contrast) dedicated breast computed tomography (CT), and longitudinally-acquired dedicated 3D breast CT and positron emission tomography (PET)/CT images. The algorithmic parameters of the DD method were optimized for the alignment of dedicated breast CT images using training data and fixed. The performance of the method for image alignment was quantitatively evaluated using three separate data sets; (1) serial breast CT pre- and post-contrast images of 20 women, (2) breast CT images of 20 women acquired before and after repositioning the subject on the scanner, and (3) dedicated breast PET/CT images of 7 women undergoing neo-adjuvant chemotherapy acquired pre-treatment and after 1 cycle of therapy. The DD registration method outperformed no registration (p < 0.001) and conventional affine registration (p ≤ 0.002) for serial and longitudinal breast CT and PET/CT image alignment. In spite of the large size of the imaging data, the computational cost of the DD method was found to be reasonable (3-5 min). Co-registration of dedicated breast CT and PET/CT images can be performed rapidly and reliably using the DD method. This is the first study evaluating the DD registration method for the alignment of dedicated breast CT and PET/CT images. Copyright © 2014 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  7. Orthogonal Rings, Fiducial Markers, and Overlay Accuracy When Image Fusion is Used for EVAR Guidance.

    PubMed

    Koutouzi, G; Sandström, C; Roos, H; Henrikson, O; Leonhardt, H; Falkenberg, M

    2016-11-01

    Evaluation of orthogonal rings, fiducial markers, and overlay accuracy when image fusion is used for endovascular aortic repair (EVAR). This was a prospective single centre study. In 19 patients undergoing standard EVAR, 3D image fusion was used for intra-operative guidance. Renal arteries and targeted stent graft positions were marked with rings orthogonal to the respective centre lines from pre-operative computed tomography (CT). Radiopaque reference objects attached to the back of the patient were used as fiducial markers to detect patient movement intra-operatively. Automatic 3D-3D registration of the pre-operative CT with an intra-operative cone beam computed tomography (CBCT) as well as 3D-3D registration after manual alignment of nearby vertebrae were evaluated. Registration was defined as being sufficient for EVAR guidance if the deviation of the origin of the lower renal artery was less than 3 mm. For final overlay registration, the renal arteries were manually aligned using aortic calcification and vessel outlines. The accuracy of the overlay before stent graft deployment was evaluated using digital subtraction angiography (DSA) as direct comparison. Fiducial markers helped in detecting misalignment caused by patient movement during the procedure. Use of automatic intensity based registration alone was insufficient for EVAR guidance. Manual registration based on vertebrae L1-L2 was sufficient in 7/19 patients (37%). Using the final adjusted registration as overlay, the median alignment error of the lower renal artery marking at pre-deployment DSA was 2 mm (0-5) sideways and 2 mm (0-9) longitudinally, mostly in a caudal direction. 3D image fusion can facilitate intra-operative guidance during EVAR. Orthogonal rings and fiducial markers are useful for visualization and overlay correction. However, the accuracy of the overlaid 3D image is not always ideal and further technical development is needed. Copyright © 2016 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.

  8. Systematic review: Outcome reporting bias is a problem in high impact factor neurology journals

    PubMed Central

    Scott, Jared T.; Blubaugh, Mark; Roepke, Brie; Scheckel, Caleb; Vassar, Matt

    2017-01-01

    Background Selective outcome reporting is a significant methodological concern. Comparisons between the outcomes reported in clinical trial registrations and those later published allow investigators to understand the extent of selection bias among trialists. We examined the possibility of selective outcome reporting in randomized controlled trials (RCTs) published in neurology journals. Methods We searched PubMed for randomized controlled trials from Jan 1, 2010 –Dec 31, 2015 published in the top 3 impact factor neurology journals. These articles were screened according to specific inclusion criteria. Each author individually extracted data from trials following a standardized protocol. A second author verified each extracted element and discrepancies were resolved. Consistency between registered and published outcomes was evaluated and correlations between discrepancies and funding, journal, and temporal trends were examined. Results 180 trials were included for analysis. 10 (6%) primary outcomes were demoted, 38 (21%) primary outcomes were omitted from the publication, and 61 (34%) unregistered primary outcomes were added to the published report. There were 18 (10%) cases of secondary outcomes being upgraded to primary outcomes in the publication, and there were 53 (29%) changes in timing of assessment. Of 82 (46%) major discrepancies with reported p-values, 54 (66.0%) favored publication of statistically significant results. Conclusion Across trials, we found 180 major discrepancies. 66% of major discrepancies with a reported p-value (n = 82) favored statistically significant results. These results suggest a need within neurology to provide more consistent and timely registration of outcomes. PMID:28727834

  9. Systematic review: Outcome reporting bias is a problem in high impact factor neurology journals.

    PubMed

    Howard, Benjamin; Scott, Jared T; Blubaugh, Mark; Roepke, Brie; Scheckel, Caleb; Vassar, Matt

    2017-01-01

    Selective outcome reporting is a significant methodological concern. Comparisons between the outcomes reported in clinical trial registrations and those later published allow investigators to understand the extent of selection bias among trialists. We examined the possibility of selective outcome reporting in randomized controlled trials (RCTs) published in neurology journals. We searched PubMed for randomized controlled trials from Jan 1, 2010 -Dec 31, 2015 published in the top 3 impact factor neurology journals. These articles were screened according to specific inclusion criteria. Each author individually extracted data from trials following a standardized protocol. A second author verified each extracted element and discrepancies were resolved. Consistency between registered and published outcomes was evaluated and correlations between discrepancies and funding, journal, and temporal trends were examined. 180 trials were included for analysis. 10 (6%) primary outcomes were demoted, 38 (21%) primary outcomes were omitted from the publication, and 61 (34%) unregistered primary outcomes were added to the published report. There were 18 (10%) cases of secondary outcomes being upgraded to primary outcomes in the publication, and there were 53 (29%) changes in timing of assessment. Of 82 (46%) major discrepancies with reported p-values, 54 (66.0%) favored publication of statistically significant results. Across trials, we found 180 major discrepancies. 66% of major discrepancies with a reported p-value (n = 82) favored statistically significant results. These results suggest a need within neurology to provide more consistent and timely registration of outcomes.

  10. Mechanistic modeling of insecticide risks to breeding birds in North American agroecosystems

    EPA Science Inventory

    Insecticide usage in the United States is ubiquitous in urban, suburban, and rural environments. In evaluating data for an insecticide registration application and for registration review, scientists at the United States Environmental Protection Agency (USEPA) assess the fate of ...

  11. 10 CFR 32.210 - Registration of product information.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... sent to the Office of Federal and State Materials and Environmental Management Programs, by an... device must include sufficient information about the design, manufacture, prototype testing, quality... the evaluation, the Commission issues a certificate of registration to the person making the request...

  12. Research Issues in Image Registration for Remote Sensing

    NASA Technical Reports Server (NTRS)

    Eastman, Roger D.; LeMoigne, Jacqueline; Netanyahu, Nathan S.

    2007-01-01

    Image registration is an important element in data processing for remote sensing with many applications and a wide range of solutions. Despite considerable investigation the field has not settled on a definitive solution for most applications and a number of questions remain open. This article looks at selected research issues by surveying the experience of operational satellite teams, application-specific requirements for Earth science, and our experiments in the evaluation of image registration algorithms with emphasis on the comparison of algorithms for subpixel accuracy. We conclude that remote sensing applications put particular demands on image registration algorithms to take into account domain-specific knowledge of geometric transformations and image content.

  13. Homographic Patch Feature Transform: A Robustness Registration for Gastroscopic Surgery.

    PubMed

    Hu, Weiling; Zhang, Xu; Wang, Bin; Liu, Jiquan; Duan, Huilong; Dai, Ning; Si, Jianmin

    2016-01-01

    Image registration is a key component of computer assistance in image guided surgery, and it is a challenging topic in endoscopic environments. In this study, we present a method for image registration named Homographic Patch Feature Transform (HPFT) to match gastroscopic images. HPFT can be used for tracking lesions and augmenting reality applications during gastroscopy. Furthermore, an overall evaluation scheme is proposed to validate the precision, robustness and uniformity of the registration results, which provides a standard for rejection of false matching pairs from corresponding results. Finally, HPFT is applied for processing in vivo gastroscopic data. The experimental results show that HPFT has stable performance in gastroscopic applications.

  14. Prospective registration trends, reasons for retrospective registration and mechanisms to increase prospective registration compliance: descriptive analysis and survey

    PubMed Central

    Seidler, Anna Lene; Askie, Lisa M

    2018-01-01

    Objectives To analyse prospective versus retrospective trial registration trends on the Australian New Zealand Clinical Trials Registry (ANZCTR) and to evaluate the reasons for non-compliance with prospective registration. Design Part 1: Descriptive analysis of trial registration trends from 2006 to 2015. Part 2: Online registrant survey. Participants Part 1: All interventional trials registered on ANZCTR from 2006 to 2015. Part 2: Random sample of those who had retrospectively registered a trial on ANZCTR between 2010 and 2015. Main outcome measures Part 1: Proportion of prospective versus retrospective clinical trial registrations (ie, registration before versus after enrolment of the first participant) on the ANZCTR overall and by various key metrics, such as sponsor, funder, recruitment country and sample size. Part 2: Reasons for non-compliance with prospective registration and perceived usefulness of various proposed mechanisms to improve prospective registration compliance. Results Part 1: Analysis of the complete dataset of 9450 trials revealed that compliance with prospective registration increased from 48% (216 out of 446 trials) in 2006 to 63% (723/1148) in 2012 and has since plateaued at around 64%. Patterns of compliance were relatively consistent across sponsor and funder types (industry vs non-industry), type of intervention (drug vs non-drug) and size of trial (n<100, 100–500, >500). However, primary sponsors from Australia/New Zealand were almost twice as likely to register prospectively (62%; 4613/7452) compared with sponsors from other countries with a WHO Network Registry (35%; 377/1084) or sponsors from countries without a WHO Registry (29%; 230/781). Part 2: The majority (56%; 84/149) of survey respondents cited lack of awareness as a reason for not registering their study prospectively. Seventy-four per cent (111/149) stated that linking registration to ethics approval would facilitate prospective registration. Conclusions Despite some progress, compliance with prospective registration remains suboptimal. Linking registration to ethics approval was the favoured strategy among those sampled for improving compliance. PMID:29496896

  15. An evaluation of vital registers as sources of data for infant mortality rates in Cameroon.

    PubMed

    Ndong, I; Gloyd, S; Gale, J

    1994-06-01

    Infant mortality rates have been widely used as indicators of health status and the availability, utilization and effectiveness of health services. Two principal sources of data for infant mortality rates are vital registers and censuses. This study was designed to evaluate the accuracy of vital registers as sources of data for infant mortality rates in Cameroon. A household census of births and infant deaths that occurred in Buea Subdivision between 1 November 1991 and 31 October 1992 was conducted to determine the proportion that were registered and the reasons why the remainder were not registered. The registration coverage was found to be 62% for births and 4% for infant deaths. The most frequently reported reasons for not registering births were lack of money, lack of time and a complicated registration procedure. For infant deaths the reasons were lack of knowledge and no perceived benefits. Vital registers of birth and death are not an accurate source of data for infant mortality rates in Cameroon. Motivation for birth and death registration appear to be dependent on the perceived benefits. A mechanism of registration that uses medical institutions may substantially increase registration coverage for births and infant deaths.

  16. Experimental Evaluation of a Deformable Registration Algorithm for Motion Correction in PET-CT Guided Biopsy.

    PubMed

    Khare, Rahul; Sala, Guillaume; Kinahan, Paul; Esposito, Giuseppe; Banovac, Filip; Cleary, Kevin; Enquobahrie, Andinet

    2013-01-01

    Positron emission tomography computed tomography (PET-CT) images are increasingly being used for guidance during percutaneous biopsy. However, due to the physics of image acquisition, PET-CT images are susceptible to problems due to respiratory and cardiac motion, leading to inaccurate tumor localization, shape distortion, and attenuation correction. To address these problems, we present a method for motion correction that relies on respiratory gated CT images aligned using a deformable registration algorithm. In this work, we use two deformable registration algorithms and two optimization approaches for registering the CT images obtained over the respiratory cycle. The two algorithms are the BSpline and the symmetric forces Demons registration. In the first optmization approach, CT images at each time point are registered to a single reference time point. In the second approach, deformation maps are obtained to align each CT time point with its adjacent time point. These deformations are then composed to find the deformation with respect to a reference time point. We evaluate these two algorithms and optimization approaches using respiratory gated CT images obtained from 7 patients. Our results show that overall the BSpline registration algorithm with the reference optimization approach gives the best results.

  17. PET guidance for liver radiofrequency ablation: an evaluation

    NASA Astrophysics Data System (ADS)

    Lei, Peng; Dandekar, Omkar; Mahmoud, Faaiza; Widlus, David; Malloy, Patrick; Shekhar, Raj

    2007-03-01

    Radiofrequency ablation (RFA) is emerging as the primary mode of treatment of unresectable malignant liver tumors. With current intraoperative imaging modalities, quick, precise, and complete localization of lesions remains a challenge for liver RFA. Fusion of intraoperative CT and preoperative PET images, which relies on PET and CT registration, can produce a new image with complementary metabolic and anatomic data and thus greatly improve the targeting accuracy. Unlike neurological images, alignment of abdominal images by combined PET/CT scanner is prone to errors as a result of large nonrigid misalignment in abdominal images. Our use of a normalized mutual information-based 3D nonrigid registration technique has proven powerful for whole-body PET and CT registration. We demonstrate here that this technique is capable of acceptable abdominal PET and CT registration as well. In five clinical cases, both qualitative and quantitative validation showed that the registration is robust and accurate. Quantitative accuracy was evaluated by comparison between the result from the algorithm and clinical experts. The accuracy of registration is much less than the allowable margin in liver RFA. Study findings show the technique's potential to enable the augmentation of intraoperative CT with preoperative PET to reduce procedure time, avoid repeating procedures, provide clinicians with complementary functional/anatomic maps, avoid omitting dispersed small lesions, and improve the accuracy of tumor targeting in liver RFA.

  18. LCC-Demons: a robust and accurate symmetric diffeomorphic registration algorithm.

    PubMed

    Lorenzi, M; Ayache, N; Frisoni, G B; Pennec, X

    2013-11-01

    Non-linear registration is a key instrument for computational anatomy to study the morphology of organs and tissues. However, in order to be an effective instrument for the clinical practice, registration algorithms must be computationally efficient, accurate and most importantly robust to the multiple biases affecting medical images. In this work we propose a fast and robust registration framework based on the log-Demons diffeomorphic registration algorithm. The transformation is parameterized by stationary velocity fields (SVFs), and the similarity metric implements a symmetric local correlation coefficient (LCC). Moreover, we show how the SVF setting provides a stable and consistent numerical scheme for the computation of the Jacobian determinant and the flux of the deformation across the boundaries of a given region. Thus, it provides a robust evaluation of spatial changes. We tested the LCC-Demons in the inter-subject registration setting, by comparing with state-of-the-art registration algorithms on public available datasets, and in the intra-subject longitudinal registration problem, for the statistically powered measurements of the longitudinal atrophy in Alzheimer's disease. Experimental results show that LCC-Demons is a generic, flexible, efficient and robust algorithm for the accurate non-linear registration of images, which can find several applications in the field of medical imaging. Without any additional optimization, it solves equally well intra & inter-subject registration problems, and compares favorably to state-of-the-art methods. Copyright © 2013 Elsevier Inc. All rights reserved.

  19. Surface-based prostate registration with biomechanical regularization

    NASA Astrophysics Data System (ADS)

    van de Ven, Wendy J. M.; Hu, Yipeng; Barentsz, Jelle O.; Karssemeijer, Nico; Barratt, Dean; Huisman, Henkjan J.

    2013-03-01

    Adding MR-derived information to standard transrectal ultrasound (TRUS) images for guiding prostate biopsy is of substantial clinical interest. A tumor visible on MR images can be projected on ultrasound by using MRUS registration. A common approach is to use surface-based registration. We hypothesize that biomechanical modeling will better control deformation inside the prostate than a regular surface-based registration method. We developed a novel method by extending a surface-based registration with finite element (FE) simulation to better predict internal deformation of the prostate. For each of six patients, a tetrahedral mesh was constructed from the manual prostate segmentation. Next, the internal prostate deformation was simulated using the derived radial surface displacement as boundary condition. The deformation field within the gland was calculated using the predicted FE node displacements and thin-plate spline interpolation. We tested our method on MR guided MR biopsy imaging data, as landmarks can easily be identified on MR images. For evaluation of the registration accuracy we used 45 anatomical landmarks located in all regions of the prostate. Our results show that the median target registration error of a surface-based registration with biomechanical regularization is 1.88 mm, which is significantly different from 2.61 mm without biomechanical regularization. We can conclude that biomechanical FE modeling has the potential to improve the accuracy of multimodal prostate registration when comparing it to regular surface-based registration.

  20. A comprehensive study on decreasing the kilovoltage cone-beam CT dose by reducing the projection number.

    PubMed

    Lu, Bo; Lu, Haibin; Palta, Jatinder

    2010-05-12

    The objective of this study was to evaluate the effect of kilovoltage cone-beam computed tomography (CBCT) on registration accuracy and image qualities with a reduced number of planar projections used in volumetric imaging reconstruction. The ultimate goal is to evaluate the possibility of reducing the patient dose while maintaining registration accuracy under different projection-number schemes for various clinical sites. An Elekta Synergy Linear accelerator with an onboard CBCT system was used in this study. The quality of the Elekta XVI cone-beam three-dimensional volumetric images reconstructed with a decreasing number of projections was quantitatively evaluated by a Catphan phantom. Subsequently, we tested the registration accuracy of imaging data sets on three rigid anthropomorphic phantoms and three real patient sites under the reduced projection-number (as low as 1/6th) reconstruction of CBCT data with different rectilinear shifts and rota-tions. CBCT scan results of the Catphan phantom indicated the CBCT images got noisier when the number of projections was reduced, but their spatial resolution and uniformity were hardly affected. The maximum registration errors under the small amount transformation of the reference CT images were found to be within 0.7 mm translation and 0.3 masculine rotation. However, when the projection number was lower than one-fourth of the full set with a large amount of transformation of reference CT images, the registration could easily be trapped into local minima solutions for a nonrigid anatomy. We concluded, by using projection-number reduction strategy under conscientious care, imaging-guided localization procedure could achieve a lower patient dose without losing the registration accuracy for various clinical sites and situations. A faster scanning time is the main advantage compared to the mA decrease-based, dose-reduction method.

  1. Registration of retinal sequences from new video-ophthalmoscopic camera.

    PubMed

    Kolar, Radim; Tornow, Ralf P; Odstrcilik, Jan; Liberdova, Ivana

    2016-05-20

    Analysis of fast temporal changes on retinas has become an important part of diagnostic video-ophthalmology. It enables investigation of the hemodynamic processes in retinal tissue, e.g. blood-vessel diameter changes as a result of blood-pressure variation, spontaneous venous pulsation influenced by intracranial-intraocular pressure difference, blood-volume changes as a result of changes in light reflection from retinal tissue, and blood flow using laser speckle contrast imaging. For such applications, image registration of the recorded sequence must be performed. Here we use a new non-mydriatic video-ophthalmoscope for simple and fast acquisition of low SNR retinal sequences. We introduce a novel, two-step approach for fast image registration. The phase correlation in the first stage removes large eye movements. Lucas-Kanade tracking in the second stage removes small eye movements. We propose robust adaptive selection of the tracking points, which is the most important part of tracking-based approaches. We also describe a method for quantitative evaluation of the registration results, based on vascular tree intensity profiles. The achieved registration error evaluated on 23 sequences (5840 frames) is 0.78 ± 0.67 pixels inside the optic disc and 1.39 ± 0.63 pixels outside the optic disc. We compared the results with the commonly used approaches based on Lucas-Kanade tracking and scale-invariant feature transform, which achieved worse results. The proposed method can efficiently correct particular frames of retinal sequences for shift and rotation. The registration results for each frame (shift in X and Y direction and eye rotation) can also be used for eye-movement evaluation during single-spot fixation tasks.

  2. Augmented Reality Using Transurethral Ultrasound for Laparoscopic Radical Prostatectomy: Preclinical Evaluation.

    PubMed

    Lanchon, Cecilia; Custillon, Guillaume; Moreau-Gaudry, Alexandre; Descotes, Jean-Luc; Long, Jean-Alexandre; Fiard, Gaelle; Voros, Sandrine

    2016-07-01

    To guide the surgeon during laparoscopic or robot-assisted radical prostatectomy an innovative laparoscopic/ultrasound fusion platform was developed using a motorized 3-dimensional transurethral ultrasound probe. We present what is to our knowledge the first preclinical evaluation of 3-dimensional prostate visualization using transurethral ultrasound and the preliminary results of this new augmented reality. The transurethral probe and laparoscopic/ultrasound registration were tested on realistic prostate phantoms made of standard polyvinyl chloride. The quality of transurethral ultrasound images and the detection of passive markers placed on the prostate surface were evaluated on 2-dimensional dynamic views and 3-dimensional reconstructions. The feasibility, precision and reproducibility of laparoscopic/transurethral ultrasound registration was then determined using 4, 5, 6 and 7 markers to assess the optimal amount needed. The root mean square error was calculated for each registration and the median root mean square error and IQR were calculated according to the number of markers. The transurethral ultrasound probe was easy to manipulate and the prostatic capsule was well visualized in 2 and 3 dimensions. Passive markers could precisely be localized in the volume. Laparoscopic/transurethral ultrasound registration procedures were performed on 74 phantoms of various sizes and shapes. All were successful. The median root mean square error of 1.1 mm (IQR 0.8-1.4) was significantly associated with the number of landmarks (p = 0.001). The highest accuracy was achieved using 6 markers. However, prostate volume did not affect registration precision. Transurethral ultrasound provided high quality prostate reconstruction and easy marker detection. Laparoscopic/ultrasound registration was successful with acceptable mm precision. Further investigations are necessary to achieve sub mm accuracy and assess feasibility in a human model. Copyright © 2016 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  3. Clinical leadership and pre-registration nursing programmes: A model for clinical leadership and a prospective curriculum implementation and evaluation research strategy.

    PubMed

    Brown, Angela; Dewing, Jan; Crookes, Patrick

    2016-07-01

    To present for wider debate a conceptual model for clinical leadership development in pre-registration nursing programmes and a proposed implementation plan. Globally, leadership in nursing has become a significant issue. Whilst there is continued support for leadership preparation in pre-registration nursing programmes, there have been very few published accounts of curriculum content and/or pedagogical approaches that foster clinical leadership development in pre-registration nursing. A doctoral research study has resulted in the creation of an overarching model for clinical leadership. A multi-method research study using theoretical and empirical literature 1974-2015, a focus group, expert opinion and a national on-line survey. A conceptual model of clinical leadership development in pre-registration nursing programme is presented, including the infinity loop of clinical leadership, an integral curriculum thread and a conceptual model: a curriculum-pedagogy nexus for clinical leadership. In order to test out usability and evaluate effectiveness, a multi method programme of research in one school of nursing in Australia is outlined. Implementation of the proposed conceptual model for clinical leadership development in pre-registration nursing programmes and a programme of (post-doctoral) research will contribute to what is known about curriculum content and pedagogy for nurse academics. Importantly, for nursing students and the profession as a whole, there is a clearer expectation of what clinical leadership might look like in the novice registered nurse. For nurse academics a model is offered for consideration in curriculum design and implementation with an evaluation strategy that could be replicated. Copyright © 2016 Elsevier Ltd. All rights reserved.

  4. Changes to registration elements and results in a cohort of Clinicaltrials.gov trials were not reflected in published articles.

    PubMed

    Pranić, Shelly; Marušić, Ana

    2016-02-01

    To assess effectiveness of legislative initiatives to stimulate public registration of trial results, we assessed adherence to protocol and results reporting, changes to registry, and publication data for randomized controlled trials (RCTs) after introduction of Food and Drug Administration Amendment Act (FDAAA). Observational study of a cohort of ClinicalTrials.gov registered FDAAA-covered RCTs found through ClinicalTrials.gov between 2009 and 2012 and data from corresponding publications. WHO Minimum Data Set items were abstracted by one author and verified by the other author. Among 81 eligible trials, most were industry-funded, with a drug intervention in parallel assignment. Secondary outcomes at the initial and last registration were omitted for 17% and 19.7% of RCTs, respectively. RCT registration changes mostly involved scientific title (18.8%). Inclusion criteria omission was most common (88%) in publications. Inferential statistical methods for primary and secondary outcomes matched between registry and publication for 53.4% and 28.6% of RCTs, respectively. Serious and other adverse events (AEs) that were absent for 23.8% and 4.8% of RCTs, respectively, were published as nonoccurring. Discrepancies remain relatively high between registered and published outcomes, particularly regarding registered omissions in publications and concomitant reporting, nature of statistical method used, and reporting of AEs. This seriously undermines transparency of clinical trials and needs immediate attention of all stakeholders in health research. Copyright © 2016 Elsevier Inc. All rights reserved.

  5. Accuracy of computer-assisted navigation: significant augmentation by facial recognition software.

    PubMed

    Glicksman, Jordan T; Reger, Christine; Parasher, Arjun K; Kennedy, David W

    2017-09-01

    Over the past 20 years, image guidance navigation has been used with increasing frequency as an adjunct during sinus and skull base surgery. These devices commonly utilize surface registration, where varying pressure of the registration probe and loss of contact with the face during the skin tracing process can lead to registration inaccuracies, and the number of registration points incorporated is necessarily limited. The aim of this study was to evaluate the use of novel facial recognition software for image guidance registration. Consecutive adults undergoing endoscopic sinus surgery (ESS) were prospectively studied. Patients underwent image guidance registration via both conventional surface registration and facial recognition software. The accuracy of both registration processes were measured at the head of the middle turbinate (MTH), middle turbinate axilla (MTA), anterior wall of sphenoid sinus (SS), and nasal tip (NT). Forty-five patients were included in this investigation. Facial recognition was accurate to within a mean of 0.47 mm at the MTH, 0.33 mm at the MTA, 0.39 mm at the SS, and 0.36 mm at the NT. Facial recognition was more accurate than surface registration at the MTH by an average of 0.43 mm (p = 0.002), at the MTA by an average of 0.44 mm (p < 0.001), and at the SS by an average of 0.40 mm (p < 0.001). The integration of facial recognition software did not adversely affect registration time. In this prospective study, automated facial recognition software significantly improved the accuracy of image guidance registration when compared to conventional surface registration. © 2017 ARS-AAOA, LLC.

  6. Image navigation and registration performance assessment tool set for the GOES-R Advanced Baseline Imager and Geostationary Lightning Mapper

    NASA Astrophysics Data System (ADS)

    De Luccia, Frank J.; Houchin, Scott; Porter, Brian C.; Graybill, Justin; Haas, Evan; Johnson, Patrick D.; Isaacson, Peter J.; Reth, Alan D.

    2016-05-01

    The GOES-R Flight Project has developed an Image Navigation and Registration (INR) Performance Assessment Tool Set (IPATS) for measuring Advanced Baseline Imager (ABI) and Geostationary Lightning Mapper (GLM) INR performance metrics in the post-launch period for performance evaluation and long term monitoring. For ABI, these metrics are the 3-sigma errors in navigation (NAV), channel-to-channel registration (CCR), frame-to-frame registration (FFR), swath-to-swath registration (SSR), and within frame registration (WIFR) for the Level 1B image products. For GLM, the single metric of interest is the 3-sigma error in the navigation of background images (GLM NAV) used by the system to navigate lightning strikes. 3-sigma errors are estimates of the 99. 73rd percentile of the errors accumulated over a 24 hour data collection period. IPATS utilizes a modular algorithmic design to allow user selection of data processing sequences optimized for generation of each INR metric. This novel modular approach minimizes duplication of common processing elements, thereby maximizing code efficiency and speed. Fast processing is essential given the large number of sub-image registrations required to generate INR metrics for the many images produced over a 24 hour evaluation period. Another aspect of the IPATS design that vastly reduces execution time is the off-line propagation of Landsat based truth images to the fixed grid coordinates system for each of the three GOES-R satellite locations, operational East and West and initial checkout locations. This paper describes the algorithmic design and implementation of IPATS and provides preliminary test results.

  7. Image Navigation and Registration (INR) Performance Assessment Tool Set (IPATS) for the GOES-R Advanced Baseline Imager and Geostationary Lightning Mapper

    NASA Technical Reports Server (NTRS)

    DeLuccia, Frank J.; Houchin, Scott; Porter, Brian C.; Graybill, Justin; Haas, Evan; Johnson, Patrick D.; Isaacson, Peter J.; Reth, Alan D.

    2016-01-01

    The GOES-R Flight Project has developed an Image Navigation and Registration (INR) Performance Assessment Tool Set (IPATS) for measuring Advanced Baseline Imager (ABI) and Geostationary Lightning Mapper (GLM) INR performance metrics in the post-launch period for performance evaluation and long term monitoring. For ABI, these metrics are the 3-sigma errors in navigation (NAV), channel-to-channel registration (CCR), frame-to-frame registration (FFR), swath-to-swath registration (SSR), and within frame registration (WIFR) for the Level 1B image products. For GLM, the single metric of interest is the 3-sigma error in the navigation of background images (GLM NAV) used by the system to navigate lightning strikes. 3-sigma errors are estimates of the 99.73rd percentile of the errors accumulated over a 24 hour data collection period. IPATS utilizes a modular algorithmic design to allow user selection of data processing sequences optimized for generation of each INR metric. This novel modular approach minimizes duplication of common processing elements, thereby maximizing code efficiency and speed. Fast processing is essential given the large number of sub-image registrations required to generate INR metrics for the many images produced over a 24 hour evaluation period. Another aspect of the IPATS design that vastly reduces execution time is the off-line propagation of Landsat based truth images to the fixed grid coordinates system for each of the three GOES-R satellite locations, operational East and West and initial checkout locations. This paper describes the algorithmic design and implementation of IPATS and provides preliminary test results.

  8. SU-G-IeP2-06: Evaluation of Registration Accuracy for Cone-Beam CT Reconstruction Techniques

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Li, J; Wang, P; Zhang, H

    2016-06-15

    Purpose: Cone-beam (CB) computed tomography (CT) is used for image guidance during radiotherapy treatment delivery. Conventional Feldkamp and compressed sensing (CS) based CBCT recon-struction techniques are compared for image registration. This study is to evaluate the image registration accuracy of conventional and CS CBCT for head-and-neck (HN) patients. Methods: Ten HN patients with oropharyngeal tumors were retrospectively selected. Each HN patient had one planning CT (CTP) and three CBCTs were acquired during an adaptive radiotherapy proto-col. Each CBCT was reconstructed by both the conventional (CBCTCON) and compressed sens-ing (CBCTCS) methods. Two oncologists manually labeled 23 landmarks of normal tissue andmore » implanted gold markers on both the CTP and CBCTCON. Subsequently, landmarks on CTp were propagated to CBCTs, using a b-spline-based deformable image registration (DIR) and rigid registration (RR). The errors of these registration methods between two CBCT methods were calcu-lated. Results: For DIR, the mean distance between the propagated and the labeled landmarks was 2.8 mm ± 0.52 for CBCTCS, and 3.5 mm ± 0.75 for CBCTCON. For RR, the mean distance between the propagated and the labeled landmarks was 6.8 mm ± 0.92 for CBCTCS, and 8.7 mm ± 0.95 CBCTCON. Conclusion: This study has demonstrated that CS CBCT is more accurate than conventional CBCT in image registration by both rigid and non-rigid methods. It is potentially suggested that CS CBCT is an improved image modality for image guided adaptive applications.« less

  9. Image Navigation and Registration Performance Assessment Tool Set for the GOES-R Advanced Baseline Imager and Geostationary Lightning Mapper

    NASA Technical Reports Server (NTRS)

    De Luccia, Frank J.; Houchin, Scott; Porter, Brian C.; Graybill, Justin; Haas, Evan; Johnson, Patrick D.; Isaacson, Peter J.; Reth, Alan D.

    2016-01-01

    The GOES-R Flight Project has developed an Image Navigation and Registration (INR) Performance Assessment Tool Set (IPATS) for measuring Advanced Baseline Imager (ABI) and Geostationary Lightning Mapper (GLM) INR performance metrics in the post-launch period for performance evaluation and long term monitoring. For ABI, these metrics are the 3-sigma errors in navigation (NAV), channel-to-channel registration (CCR), frame-to-frame registration (FFR), swath-to-swath registration (SSR), and within frame registration (WIFR) for the Level 1B image products. For GLM, the single metric of interest is the 3-sigma error in the navigation of background images (GLM NAV) used by the system to navigate lightning strikes. 3-sigma errors are estimates of the 99.73rd percentile of the errors accumulated over a 24-hour data collection period. IPATS utilizes a modular algorithmic design to allow user selection of data processing sequences optimized for generation of each INR metric. This novel modular approach minimizes duplication of common processing elements, thereby maximizing code efficiency and speed. Fast processing is essential given the large number of sub-image registrations required to generate INR metrics for the many images produced over a 24-hour evaluation period. Another aspect of the IPATS design that vastly reduces execution time is the off-line propagation of Landsat based truth images to the fixed grid coordinates system for each of the three GOES-R satellite locations, operational East and West and initial checkout locations. This paper describes the algorithmic design and implementation of IPATS and provides preliminary test results.

  10. Semiautomatic registration of 3D transabdominal ultrasound images for patient repositioning during postprostatectomy radiotherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Presles, Benoît, E-mail: benoit.presles@creatis.insa-lyon.fr; Rit, Simon; Sarrut, David

    2014-12-15

    Purpose: The aim of the present work is to propose and evaluate registration algorithms of three-dimensional (3D) transabdominal (TA) ultrasound (US) images to setup postprostatectomy patients during radiation therapy. Methods: Three registration methods have been developed and evaluated to register a reference 3D-TA-US image acquired during the planning CT session and a 3D-TA-US image acquired before each treatment session. The first method (method A) uses only gray value information, whereas the second one (method B) uses only gradient information. The third one (method C) combines both sets of information. All methods restrict the comparison to a region of interest computedmore » from the dilated reference positioning volume drawn on the reference image and use mutual information as a similarity measure. The considered geometric transformations are translations and have been optimized by using the adaptive stochastic gradient descent algorithm. Validation has been carried out using manual registration by three operators of the same set of image pairs as the algorithms. Sixty-two treatment US images of seven patients irradiated after a prostatectomy have been registered to their corresponding reference US image. The reference registration has been defined as the average of the manual registration values. Registration error has been calculated by subtracting the reference registration from the algorithm result. For each session, the method has been considered a failure if the registration error was above both the interoperator variability of the session and a global threshold of 3.0 mm. Results: All proposed registration algorithms have no systematic bias. Method B leads to the best results with mean errors of −0.6, 0.7, and −0.2 mm in left–right (LR), superior–inferior (SI), and anterior–posterior (AP) directions, respectively. With this method, the standard deviations of the mean error are of 1.7, 2.4, and 2.6 mm in LR, SI, and AP directions, respectively. The latter are inferior to the interoperator registration variabilities which are of 2.5, 2.5, and 3.5 mm in LR, SI, and AP directions, respectively. Failures occur in 5%, 18%, and 10% of cases in LR, SI, and AP directions, respectively. 69% of the sessions have no failure. Conclusions: Results of the best proposed registration algorithm of 3D-TA-US images for postprostatectomy treatment have no bias and are in the same variability range as manual registration. As the algorithm requires a short computation time, it could be used in clinical practice provided that a visual review is performed.« less

  11. An individualized strategy to estimate the effect of deformable registration uncertainty on accumulated dose in the upper abdomen

    NASA Astrophysics Data System (ADS)

    Wang, Yibing; Petit, Steven F.; Vásquez Osorio, Eliana; Gupta, Vikas; Méndez Romero, Alejandra; Heijmen, Ben

    2018-06-01

    In the abdomen, it is challenging to assess the accuracy of deformable image registration (DIR) for individual patients, due to the lack of clear anatomical landmarks, which can hamper clinical applications that require high accuracy DIR, such as adaptive radiotherapy. In this study, we propose and evaluate a methodology for estimating the impact of uncertainties in DIR on calculated accumulated dose in the upper abdomen, in order to aid decision making in adaptive treatment approaches. Sixteen liver metastasis patients treated with SBRT were evaluated. Each patient had one planning and three daily treatment CT-scans. Each daily CT scan was deformably registered 132 times to the planning CT-scan, using a wide range of parameter settings for the registration algorithm. A subset of ‘realistic’ registrations was then objectively selected based on distances between mapped and target contours. The underlying 3D transformations of these registrations were used to assess the corresponding uncertainties in voxel positions, and delivered dose, with a focus on accumulated maximum doses in the hollow OARs, i.e. esophagus, stomach, and duodenum. The number of realistic registrations varied from 5 to 109, depending on the patient, emphasizing the need for individualized registration parameters. Considering for all patients the realistic registrations, the 99th percentile of the voxel position uncertainties was 5.6  ±  3.3 mm. This translated into a variation (difference between 1st and 99th percentile) in accumulated D max in hollow OARs of up to 3.3 Gy. For one patient a violation of the accumulated stomach dose outside the uncertainty band was detected. The observed variation in accumulated doses in the OARs related to registration uncertainty, emphasizes the need to investigate the impact of this uncertainty for any DIR algorithm prior to clinical use for dose accumulation. The proposed method for assessing on an individual patient basis the impact of uncertainties in DIR on accumulated dose is in principle applicable for all DIR algorithms allowing variation in registration parameters.

  12. Evaluation of registration, compression and classification algorithms. Volume 1: Results

    NASA Technical Reports Server (NTRS)

    Jayroe, R.; Atkinson, R.; Callas, L.; Hodges, J.; Gaggini, B.; Peterson, J.

    1979-01-01

    The registration, compression, and classification algorithms were selected on the basis that such a group would include most of the different and commonly used approaches. The results of the investigation indicate clearcut, cost effective choices for registering, compressing, and classifying multispectral imagery.

  13. A REGIONAL APPROACH TO ECOLOGICAL RISK ASSESSMENTS FOR PRODUCT REGISTRATION

    EPA Science Inventory

    Currently, most ecological risk assessments for EPA registration are evaluated at the national scale using a predetermined list of species with little regard to where the product will ultimately be used. The assumption is that the test species presently used are representative a...

  14. Canny edge-based deformable image registration

    NASA Astrophysics Data System (ADS)

    Kearney, Vasant; Huang, Yihui; Mao, Weihua; Yuan, Baohong; Tang, Liping

    2017-02-01

    This work focuses on developing a 2D Canny edge-based deformable image registration (Canny DIR) algorithm to register in vivo white light images taken at various time points. This method uses a sparse interpolation deformation algorithm to sparsely register regions of the image with strong edge information. A stability criterion is enforced which removes regions of edges that do not deform in a smooth uniform manner. Using a synthetic mouse surface ground truth model, the accuracy of the Canny DIR algorithm was evaluated under axial rotation in the presence of deformation. The accuracy was also tested using fluorescent dye injections, which were then used for gamma analysis to establish a second ground truth. The results indicate that the Canny DIR algorithm performs better than rigid registration, intensity corrected Demons, and distinctive features for all evaluation matrices and ground truth scenarios. In conclusion Canny DIR performs well in the presence of the unique lighting and shading variations associated with white-light-based image registration.

  15. LANDSAT-4 MSS Geometric Correction: Methods and Results

    NASA Technical Reports Server (NTRS)

    Brooks, J.; Kimmer, E.; Su, J.

    1984-01-01

    An automated image registration system such as that developed for LANDSAT-4 can produce all of the information needed to verify and calibrate the software and to evaluate system performance. The on-line MSS archive generation process which upgrades systematic correction data to geodetic correction data is described as well as the control point library build subsystem which generates control point chips and support data for on-line upgrade of correction data. The system performance was evaluated for both temporal and geodetic registration. For temporal registration, 90% errors were computed to be .36 IFOV (instantaneous field of view) = 82.7 meters) cross track, and .29 IFOV along track. Also, for actual production runs monitored, the 90% errors were .29 IFOV cross track and .25 IFOV along track. The system specification is .3 IFOV, 90% of the time, both cross and along track. For geodetic registration performance, the model bias was measured by designating control points in the geodetically corrected imagery.

  16. Hyperbolic Harmonic Mapping for Surface Registration

    PubMed Central

    Shi, Rui; Zeng, Wei; Su, Zhengyu; Jiang, Jian; Damasio, Hanna; Lu, Zhonglin; Wang, Yalin; Yau, Shing-Tung; Gu, Xianfeng

    2016-01-01

    Automatic computation of surface correspondence via harmonic map is an active research field in computer vision, computer graphics and computational geometry. It may help document and understand physical and biological phenomena and also has broad applications in biometrics, medical imaging and motion capture inducstries. Although numerous studies have been devoted to harmonic map research, limited progress has been made to compute a diffeomorphic harmonic map on general topology surfaces with landmark constraints. This work conquers this problem by changing the Riemannian metric on the target surface to a hyperbolic metric so that the harmonic mapping is guaranteed to be a diffeomorphism under landmark constraints. The computational algorithms are based on Ricci flow and nonlinear heat diffusion methods. The approach is general and robust. We employ our algorithm to study the constrained surface registration problem which applies to both computer vision and medical imaging applications. Experimental results demonstrate that, by changing the Riemannian metric, the registrations are always diffeomorphic and achieve relatively high performance when evaluated with some popular surface registration evaluation standards. PMID:27187948

  17. Point cloud registration from local feature correspondences-Evaluation on challenging datasets.

    PubMed

    Petricek, Tomas; Svoboda, Tomas

    2017-01-01

    Registration of laser scans, or point clouds in general, is a crucial step of localization and mapping with mobile robots or in object modeling pipelines. A coarse alignment of the point clouds is generally needed before applying local methods such as the Iterative Closest Point (ICP) algorithm. We propose a feature-based approach to point cloud registration and evaluate the proposed method and its individual components on challenging real-world datasets. For a moderate overlap between the laser scans, the method provides a superior registration accuracy compared to state-of-the-art methods including Generalized ICP, 3D Normal-Distribution Transform, Fast Point-Feature Histograms, and 4-Points Congruent Sets. Compared to the surface normals, the points as the underlying features yield higher performance in both keypoint detection and establishing local reference frames. Moreover, sign disambiguation of the basis vectors proves to be an important aspect in creating repeatable local reference frames. A novel method for sign disambiguation is proposed which yields highly repeatable reference frames.

  18. Comparison of subpixel image registration algorithms

    NASA Astrophysics Data System (ADS)

    Boye, R. R.; Nelson, C. L.

    2009-02-01

    Research into the use of multiframe superresolution has led to the development of algorithms for providing images with enhanced resolution using several lower resolution copies. An integral component of these algorithms is the determination of the registration of each of the low resolution images to a reference image. Without this information, no resolution enhancement can be attained. We have endeavored to find a suitable method for registering severely undersampled images by comparing several approaches. To test the algorithms, an ideal image is input to a simulated image formation program, creating several undersampled images with known geometric transformations. The registration algorithms are then applied to the set of low resolution images and the estimated registration parameters compared to the actual values. This investigation is limited to monochromatic images (extension to color images is not difficult) and only considers global geometric transformations. Each registration approach will be reviewed and evaluated with respect to the accuracy of the estimated registration parameters as well as the computational complexity required. In addition, the effects of image content, specifically spatial frequency content, as well as the immunity of the registration algorithms to noise will be discussed.

  19. Automatic Marker-free Longitudinal Infrared Image Registration by Shape Context Based Matching and Competitive Winner-guided Optimal Corresponding

    PubMed Central

    Lee, Chia-Yen; Wang, Hao-Jen; Lai, Jhih-Hao; Chang, Yeun-Chung; Huang, Chiun-Sheng

    2017-01-01

    Long-term comparisons of infrared image can facilitate the assessment of breast cancer tissue growth and early tumor detection, in which longitudinal infrared image registration is a necessary step. However, it is hard to keep markers attached on a body surface for weeks, and rather difficult to detect anatomic fiducial markers and match them in the infrared image during registration process. The proposed study, automatic longitudinal infrared registration algorithm, develops an automatic vascular intersection detection method and establishes feature descriptors by shape context to achieve robust matching, as well as to obtain control points for the deformation model. In addition, competitive winner-guided mechanism is developed for optimal corresponding. The proposed algorithm is evaluated in two ways. Results show that the algorithm can quickly lead to accurate image registration and that the effectiveness is superior to manual registration with a mean error being 0.91 pixels. These findings demonstrate that the proposed registration algorithm is reasonably accurate and provide a novel method of extracting a greater amount of useful data from infrared images. PMID:28145474

  20. The heritability of the functional connectome is robust to common nonlinear registration methods

    NASA Astrophysics Data System (ADS)

    Hafzalla, George W.; Prasad, Gautam; Baboyan, Vatche G.; Faskowitz, Joshua; Jahanshad, Neda; McMahon, Katie L.; de Zubicaray, Greig I.; Wright, Margaret J.; Braskie, Meredith N.; Thompson, Paul M.

    2016-03-01

    Nonlinear registration algorithms are routinely used in brain imaging, to align data for inter-subject and group comparisons, and for voxelwise statistical analyses. To understand how the choice of registration method affects maps of functional brain connectivity in a sample of 611 twins, we evaluated three popular nonlinear registration methods: Advanced Normalization Tools (ANTs), Automatic Registration Toolbox (ART), and FMRIB's Nonlinear Image Registration Tool (FNIRT). Using both structural and functional MRI, we used each of the three methods to align the MNI152 brain template, and 80 regions of interest (ROIs), to each subject's T1-weighted (T1w) anatomical image. We then transformed each subject's ROIs onto the associated resting state functional MRI (rs-fMRI) scans and computed a connectivity network or functional connectome for each subject. Given the different degrees of genetic similarity between pairs of monozygotic (MZ) and same-sex dizygotic (DZ) twins, we used structural equation modeling to estimate the additive genetic influences on the elements of the function networks, or their heritability. The functional connectome and derived statistics were relatively robust to nonlinear registration effects.

  1. Evaluation of LANDSAT multispectral scanner images for mapping altered rocks in the east Tintic Mountains, Utah

    NASA Technical Reports Server (NTRS)

    Rowan, L. C.; Abrams, M. J. (Principal Investigator)

    1979-01-01

    The author has identified the following significant results. Positive findings of earlier evaluations of the color-ratio compositing technique for mapping limonitic altered rocks in south-central Nevada are confirmed, but important limitations in the approach used are pointed out. These limitations arise from environmental, geologic, and image processing factors. The greater vegetation density in the East Tintic Mountains required several modifications in procedures to improve the overall mapping accuracy of the CRC approach. Large format ratio images provide better internal registration of the diazo films and avoids the problems associated with magnifications required in the original procedure. Use of the Linoscan 204 color recognition scanner permits accurate consistent extraction of the green pixels representing limonitic bedrock maps that can be used for mapping at large scales as well as for small scale reconnaissance.

  2. Clinical trial regulation in Argentina: overview and analysis of regulatory framework, use of existing tools, and researchers' perspectives to identify potential barriers.

    PubMed

    White, Lauren; Ortiz, Zulma; Cuervo, Luis G; Reveiz, Ludovic

    2011-11-01

    To review and analyze the regulatory framework of clinical trial registration, use of existing tools (publicly accessible national/international registration databases), and users' perspectives to identify possible barriers to registration compliance by sponsors and researchers in Argentina. Internationally registered trials recruiting patients in Argentina were found through clincialtrials.gov and the International Clinical Trial Registration Platform (ICTRP) and compared with publically available clinical trials registered through the National Administration of Drugs, Foods, and Medical Devices (ANMAT). A questionnaire addressing hypothesized attitudinal, knowledge-related, idiomatic, technical, economic, and regulatory barriers that could discourage or impede registration of clinical trials was developed, and semi-structured, in-depth interviews were conducted with a purposively selected sample of researchers (investigators, sponsors, and monitors) in Argentina. A response rate of 74.3% (n = 29) was achieved, and 27 interviews were ultimately used for analysis. Results suggested that the high proportion of foreign-sponsored or multinational trials (64.8% of all protocols approved by ANMAT from 1994-2006) may contribute to a communication gap between locally based investigators and foreign-based administrative officials. A lack of knowledge about available international registration tools and limited awareness of the importance of registration were also identified as limiting factors for local investigators and sponsors. To increase compliance and promote clinical trial registration in Argentina, national health authorities, sponsors, and local investigators could take the following steps: implement a grassroots educational campaign to improve clinical trial regulation, support local investigator-sponsor-initiated clinical trials, and/or encourage local and regional scientific journal compliance with standards from the International Committee of Medical Journal Editors (ICMJE) and/or the World Association of Medical Editors (WAME).

  3. Using direct mail to promote organ donor registration: Two campaigns and a meta-analysis.

    PubMed

    Feeley, Thomas H; Quick, Brian L; Lee, Seyoung

    2016-12-01

    Two direct mail campaigns were undertaken in Rochester and Buffalo, New York, with the goal of enrolling adults aged 50-64 years into the state organ and tissue donation electronic registry. Meta-analytic methods were used to summarize the body of research on the effects of direct mail marketing to promote organ donation registration. In the first study, 40 000 mailers were sent to targeted adults in Rochester, New York, and varied by brochure-only, letter-only, and letter plus brochure mailing conditions. A follow-up mailer using letter-only was sent to 20 000 individuals in Buffalo, New York area. In a second study, campaign results were combined with previously published direct mail campaigns in a random-effects meta-analysis. The overall registration rates were 1.6% and 4.6% for the Rochester and Buffalo campaigns, and the letter-only condition outperformed the brochure-only and letter plus brochure conditions in the Rochester area campaigns. Meta-analysis indicated a 3.3% registration rates across 15 campaigns and 329 137 targeted individuals. Registration rates were higher when targeting 18-year-olds and when direct mail letters were authored by officials affiliated with state departments. Use of direct mail to promote organ donor registration is an inexpensive method to increase enrollments in state registries. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  4. Registration of pencil beam proton radiography data with X-ray CT.

    PubMed

    Deffet, Sylvain; Macq, Benoît; Righetto, Roberto; Vander Stappen, François; Farace, Paolo

    2017-10-01

    Proton radiography seems to be a promising tool for assessing the quality of the stopping power computation in proton therapy. However, range error maps obtained on the basis of proton radiographs are very sensitive to small misalignment between the planning CT and the proton radiography acquisitions. In order to be able to mitigate misalignment in postprocessing, the authors implemented a fast method for registration between pencil proton radiography data obtained with a multilayer ionization chamber (MLIC) and an X-ray CT acquired on a head phantom. The registration was performed by optimizing a cost function which performs a comparison between the acquired data and simulated integral depth-dose curves. Two methodologies were considered, one based on dual orthogonal projections and the other one on a single projection. For each methodology, the robustness of the registration algorithm with respect to three confounding factors (measurement noise, CT calibration errors, and spot spacing) was investigated by testing the accuracy of the method through simulations based on a CT scan of a head phantom. The present registration method showed robust convergence towards the optimal solution. For the level of measurement noise and the uncertainty in the stopping power computation expected in proton radiography using a MLIC, the accuracy appeared to be better than 0.3° for angles and 0.3 mm for translations by use of the appropriate cost function. The spot spacing analysis showed that a spacing larger than the 5 mm used by other authors for the investigation of a MLIC for proton radiography led to results with absolute accuracy better than 0.3° for angles and 1 mm for translations when orthogonal proton radiographs were fed into the algorithm. In the case of a single projection, 6 mm was the largest spot spacing presenting an acceptable registration accuracy. For registration of proton radiography data with X-ray CT, the use of a direct ray-tracing algorithm to compute sums of squared differences and corrections of range errors showed very good accuracy and robustness with respect to three confounding factors: measurement noise, calibration error, and spot spacing. It is therefore a suitable algorithm to use in the in vivo range verification framework, allowing to separate in postprocessing the proton range uncertainty due to setup errors from the other sources of uncertainty. © 2017 American Association of Physicists in Medicine.

  5. 2D and 3D registration methods for dual-energy contrast-enhanced digital breast tomosynthesis

    NASA Astrophysics Data System (ADS)

    Lau, Kristen C.; Roth, Susan; Maidment, Andrew D. A.

    2014-03-01

    Contrast-enhanced digital breast tomosynthesis (CE-DBT) uses an iodinated contrast agent to image the threedimensional breast vasculature. The University of Pennsylvania is conducting a CE-DBT clinical study in patients with known breast cancers. The breast is compressed continuously and imaged at four time points (1 pre-contrast; 3 postcontrast). A hybrid subtraction scheme is proposed. First, dual-energy (DE) images are obtained by a weighted logarithmic subtraction of the high-energy and low-energy image pairs. Then, post-contrast DE images are subtracted from the pre-contrast DE image. This hybrid temporal subtraction of DE images is performed to analyze iodine uptake, but suffers from motion artifacts. Employing image registration further helps to correct for motion, enhancing the evaluation of vascular kinetics. Registration using ANTS (Advanced Normalization Tools) is performed in an iterative manner. Mutual information optimization first corrects large-scale motions. Normalized cross-correlation optimization then iteratively corrects fine-scale misalignment. Two methods have been evaluated: a 2D method using a slice-by-slice approach, and a 3D method using a volumetric approach to account for out-of-plane breast motion. Our results demonstrate that iterative registration qualitatively improves with each iteration (five iterations total). Motion artifacts near the edge of the breast are corrected effectively and structures within the breast (e.g. blood vessels, surgical clip) are better visualized. Statistical and clinical evaluations of registration accuracy in the CE-DBT images are ongoing.

  6. Framework for 3D histologic reconstruction and fusion with in vivo MRI: Preliminary results of characterizing pulmonary inflammation in a mouse model.

    PubMed

    Rusu, Mirabela; Golden, Thea; Wang, Haibo; Gow, Andrew; Madabhushi, Anant

    2015-08-01

    Pulmonary inflammation is associated with a variety of diseases. Assessing pulmonary inflammation on in vivo imaging may facilitate the early detection and treatment of lung diseases. Although routinely used in thoracic imaging, computed tomography has thus far not been compellingly shown to characterize inflammation in vivo. Alternatively, magnetic resonance imaging (MRI) is a nonionizing radiation technique to better visualize and characterize pulmonary tissue. Prior to routine adoption of MRI for early characterization of inflammation in humans, a rigorous and quantitative characterization of the utility of MRI to identify inflammation is required. Such characterization may be achieved by considering ex vivo histology as the ground truth, since it enables the definitive spatial assessment of inflammation. In this study, the authors introduce a novel framework to integrate 2D histology, ex vivo and in vivo imaging to enable the mapping of the extent of disease from ex vivo histology onto in vivo imaging, with the goal of facilitating computerized feature analysis and interrogation of disease appearance on in vivo imaging. The authors' framework was evaluated in a preclinical preliminary study aimed to identify computer extracted features on in vivo MRI associated with chronic pulmonary inflammation. The authors' image analytics framework first involves reconstructing the histologic volume in 3D from individual histology slices. Second, the authors map the disease ground truth onto in vivo MRI via coregistration with 3D histology using the ex vivo lung MRI as a conduit. Finally, computerized feature analysis of the disease extent is performed to identify candidate in vivo imaging signatures of disease presence and extent. The authors evaluated the framework by assessing the quality of the 3D histology reconstruction and the histology-MRI fusion, in the context of an initial use case involving characterization of chronic inflammation in a mouse model. The authors' evaluation considered three mice, two with an inflammation phenotype and one control. The authors' iterative 3D histology reconstruction yielded a 70.1% ± 2.7% overlap with the ex vivo MRI volume. Across a total of 17 anatomic landmarks manually delineated at the division of airways, the target registration error between the ex vivo MRI and 3D histology reconstruction was 0.85 ± 0.44 mm, suggesting that a good alignment of the ex vivo 3D histology and ex vivo MRI had been achieved. The 3D histology-in vivo MRI coregistered volumes resulted in an overlap of 73.7% ± 0.9%. Preliminary computerized feature analysis was performed on an additional four control mice, for a total of seven mice considered in this study. Gabor texture filters appeared to best capture differences between the inflamed and noninflamed regions on MRI. The authors' 3D histology reconstruction and multimodal registration framework were successfully employed to reconstruct the histology volume of the lung and fuse it with in vivo MRI to create a ground truth map for inflammation on in vivo MRI. The analytic platform presented here lays the framework for a rigorous validation of the identified imaging features for chronic lung inflammation on MRI in a large prospective cohort.

  7. 31 CFR 500.557 - Proceeds of insurance policies.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... are issued authorizing payment of the proceeds of blocked life insurance policies issued on the life... registration card; (iii) Permanent resident alien card; or (iv) National identity card. Other documents tending...

  8. What criteria for pharmaceuticals reimbursement? An empirical analysis of the evaluation of "medical service rendered" by reimbursable drugs in France.

    PubMed

    Le Pen, C; Priol, G; Lilliu, H

    2003-01-01

    The criteria for the registration of new drugs may differ from the criteria for drug reimbursement. In 2000 the French government entrusted the French Medicines Agency with determining the "medical service rendered" (MSR) for each reimbursable drug. The goal was to determine which drugs could be classified with an "insufficient" MSR and therefore should be taken out of the scope of health insurance. We analyze the concepts and methods used for this evaluation and the kind of results that are obtained. We collected data on the result of MSR classification and the criteria used to perform this classification (efficacy-security, severity of the disease,place in the therapeutic strategy, existence of therapeutic alternative, public health value) for a sample of 1453 drugs belonging to five therapeutic areas. We used statistical analysis to determine what were the most influential criteria. Only two criteria - efficacy and disease severity - suffice to very largely explain the MSR classification. The other criteria contribute little added value. Some of these criteria clearly suffer from a lack of clarification, leading to different interpretations according to therapeutic class or even according to drug or drug family. The evaluation procedure differs between therapeutic classes, at least at intermediate MSR levels. Analysis of the French experience with MSR shows that the evaluation procedure has not succeeded in completely breaking away from the traditional logic of the marketing authorization and registration, as witnessed by the importance of the "efficacy/safety" criterion, the absence of an economic criterion, and the vagueness of the "public health value" criterion, which one would have thought would instead be decisive.

  9. Deformable image registration using convolutional neural networks

    NASA Astrophysics Data System (ADS)

    Eppenhof, Koen A. J.; Lafarge, Maxime W.; Moeskops, Pim; Veta, Mitko; Pluim, Josien P. W.

    2018-03-01

    Deformable image registration can be time-consuming and often needs extensive parameterization to perform well on a specific application. We present a step towards a registration framework based on a three-dimensional convolutional neural network. The network directly learns transformations between pairs of three-dimensional images. The outputs of the network are three maps for the x, y, and z components of a thin plate spline transformation grid. The network is trained on synthetic random transformations, which are applied to a small set of representative images for the desired application. Training therefore does not require manually annotated ground truth deformation information. The methodology is demonstrated on public data sets of inspiration-expiration lung CT image pairs, which come with annotated corresponding landmarks for evaluation of the registration accuracy. Advantages of this methodology are its fast registration times and its minimal parameterization.

  10. USDA registration and rectification requirements

    NASA Technical Reports Server (NTRS)

    Allen, R.

    1982-01-01

    Some of the requirements of the United States Department of Agriculture for accuracy of aerospace acquired data, and specifically, requirements for registration and rectification of remotely sensed data are discussed. Particular attention is given to foreign and domestic crop estimation and forecasting, forestry information applications, and rangeland condition evaluations.

  11. Simulation Models Evaluation of Pest Resistance Development to Refuge in the Bag Concepts Related to Pioneer Submission

    EPA Science Inventory

    The USEPA, under its administration of the Federal Insecticide Fungicide and Rodenticide Act (FIFRA), requires the registration of all pesticides and pesticidal materials. The GM crops containing pesticidal traits are subject to FIFRA registration requirements. Concerns relating ...

  12. 77 FR 68123 - Privacy Act of 1974; System of Records Notice

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-11-15

    ... test records, including registrant's first and last name, evaluation data, pretest and posttest scores..., pretest and posttest scores, and registration information, will be disclosed to accrediting bodies (such... educational information, training, best practices, and tools to health professionals as one initiative to help...

  13. A Knowledge Use Perspective: Comments on a Conference.

    ERIC Educational Resources Information Center

    Fisher, Evelyn

    The papers from the 1982 conference on Pennsylvania's Long Range Plan for School Improvement (LRPSI) assist in constructing reality about LRPSI itself. Focusing on the program's registration phase, Charles Gorman offers an alternative proposal, linking registration and evaluation, that would contribute to improving schools and increasing public…

  14. 76 FR 552 - Pesticides; Availability of Pesticide Registration Notice Regarding the Residential Exposure...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-01-05

    ... interested persons about important policies, procedures, and registration related decisions, and serve to...: Richard P. Dumas, Pesticide Re- evaluation Division, Office of Pesticide Programs, Environmental... applicability of this action to a particular entity, consult the person listed under FOR FURTHER INFORMATION...

  15. Third molar development: evaluation of nine tooth development registration techniques for age estimations.

    PubMed

    Thevissen, Patrick W; Fieuws, Steffen; Willems, Guy

    2013-03-01

    Multiple third molar development registration techniques exist. Therefore the aim of this study was to detect which third molar development registration technique was most promising to use as a tool for subadult age estimation. On a collection of 1199 panoramic radiographs the development of all present third molars was registered following nine different registration techniques [Gleiser, Hunt (GH); Haavikko (HV); Demirjian (DM); Raungpaka (RA); Gustafson, Koch (GK); Harris, Nortje (HN); Kullman (KU); Moorrees (MO); Cameriere (CA)]. Regression models with age as response and the third molar registration as predictor were developed for each registration technique separately. The MO technique disclosed highest R(2) (F 51%, M 45%) and lowest root mean squared error (F 3.42 years; M 3.67 years) values, but differences with other techniques were small in magnitude. The amount of stages utilized in the explored staging techniques slightly influenced the age predictions. © 2013 American Academy of Forensic Sciences.

  16. Investigation of 3D histograms of oriented gradients for image-based registration of CT with interventional CBCT

    NASA Astrophysics Data System (ADS)

    Trimborn, Barbara; Wolf, Ivo; Abu-Sammour, Denis; Henzler, Thomas; Schad, Lothar R.; Zöllner, Frank G.

    2017-03-01

    Image registration of preprocedural contrast-enhanced CTs to intraprocedual cone-beam computed tomography (CBCT) can provide additional information for interventional liver oncology procedures such as transcatheter arterial chemoembolisation (TACE). In this paper, a novel similarity metric for gradient-based image registration is proposed. The metric relies on the patch-based computation of histograms of oriented gradients (HOG) building the basis for a feature descriptor. The metric was implemented in a framework for rigid 3D-3D-registration of pre-interventional CT with intra-interventional CBCT data obtained during the workflow of a TACE. To evaluate the performance of the new metric, the capture range was estimated based on the calculation of the mean target registration error and compared to the results obtained with a normalized cross correlation metric. The results show that 3D HOG feature descriptors are suitable as image-similarity metric and that the novel metric can compete with established methods in terms of registration accuracy

  17. Lung texture in serial thoracic CT scans: Assessment of change introduced by image registration1

    PubMed Central

    Cunliffe, Alexandra R.; Al-Hallaq, Hania A.; Labby, Zacariah E.; Pelizzari, Charles A.; Straus, Christopher; Sensakovic, William F.; Ludwig, Michelle; Armato, Samuel G.

    2012-01-01

    Purpose: The aim of this study was to quantify the effect of four image registration methods on lung texture features extracted from serial computed tomography (CT) scans obtained from healthy human subjects. Methods: Two chest CT scans acquired at different time points were collected retrospectively for each of 27 patients. Following automated lung segmentation, each follow-up CT scan was registered to the baseline scan using four algorithms: (1) rigid, (2) affine, (3) B-splines deformable, and (4) demons deformable. The registration accuracy for each scan pair was evaluated by measuring the Euclidean distance between 150 identified landmarks. On average, 1432 spatially matched 32 × 32-pixel region-of-interest (ROI) pairs were automatically extracted from each scan pair. First-order, fractal, Fourier, Laws’ filter, and gray-level co-occurrence matrix texture features were calculated in each ROI, for a total of 140 features. Agreement between baseline and follow-up scan ROI feature values was assessed by Bland–Altman analysis for each feature; the range spanned by the 95% limits of agreement of feature value differences was calculated and normalized by the average feature value to obtain the normalized range of agreement (nRoA). Features with small nRoA were considered “registration-stable.” The normalized bias for each feature was calculated from the feature value differences between baseline and follow-up scans averaged across all ROIs in every patient. Because patients had “normal” chest CT scans, minimal change in texture feature values between scan pairs was anticipated, with the expectation of small bias and narrow limits of agreement. Results: Registration with demons reduced the Euclidean distance between landmarks such that only 9% of landmarks were separated by ≥1 mm, compared with rigid (98%), affine (95%), and B-splines (90%). Ninety-nine of the 140 (71%) features analyzed yielded nRoA > 50% for all registration methods, indicating that the majority of feature values were perturbed following registration. Nineteen of the features (14%) had nRoA < 15% following demons registration, indicating relative feature value stability. Student's t-tests showed that the nRoA of these 19 features was significantly larger when rigid, affine, or B-splines registration methods were used compared with demons registration. Demons registration yielded greater normalized bias in feature value change than B-splines registration, though this difference was not significant (p = 0.15). Conclusions: Demons registration provided higher spatial accuracy between matched anatomic landmarks in serial CT scans than rigid, affine, or B-splines algorithms. Texture feature changes calculated in healthy lung tissue from serial CT scans were smaller following demons registration compared with all other algorithms. Though registration altered the values of the majority of texture features, 19 features remained relatively stable after demons registration, indicating their potential for detecting pathologic change in serial CT scans. Combined use of accurate deformable registration using demons and texture analysis may allow for quantitative evaluation of local changes in lung tissue due to disease progression or treatment response. PMID:22894392

  18. 2D/3D registration using a rotation-invariant cost function based on Zernike moments

    NASA Astrophysics Data System (ADS)

    Birkfellner, Wolfgang; Yang, Xinhui; Burgstaller, Wolfgang; Baumann, Bernard; Jacob, Augustinus L.; Niederer, Peter F.; Regazzoni, Pietro; Messmer, Peter

    2004-05-01

    We present a novel in-plane rotation invariant cost function for 2D/3D registration utilizing projection-invariant transformation properties and the decomposition of the X-ray nad the DRR under comparision into orhogonal Zernike moments. As a result, only five dof have to be optimized, and the number of iteration necessary for registration can be significantly reduced. Results in a phantom study show that an accuracy of approximately 0.7° and 2 mm can be achieved using this method. We conclude that reduction of coupled dof and usage of linear independent coefficients for cost function evaluation provide intersting new perspectives for the field of 2D/3D registration.

  19. 46 CFR 402.220 - Registration of pilots.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... in search and rescue and civil defense procedures as issued by the U.S. Coast Guard, Federal, State, and local port authorities. (5) Instruction in basic helm and engine telegraph orders in the Greek...

  20. 46 CFR 402.220 - Registration of pilots.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... in search and rescue and civil defense procedures as issued by the U.S. Coast Guard, Federal, State, and local port authorities. (5) Instruction in basic helm and engine telegraph orders in the Greek...

  1. 46 CFR 402.220 - Registration of pilots.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... in search and rescue and civil defense procedures as issued by the U.S. Coast Guard, Federal, State, and local port authorities. (5) Instruction in basic helm and engine telegraph orders in the Greek...

  2. 22 CFR 92.73 - Services in connection with trademark registrations.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ...)). (See § 92.72(c) regarding the authentication of the authority of a foreign official who performs a..., taking an acknowledgment, or supplying an authentication, in connection with an application for...

  3. 46 CFR 402.220 - Registration of pilots.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... in search and rescue and civil defense procedures as issued by the U.S. Coast Guard, Federal, State, and local port authorities. (5) Instruction in basic helm and engine telegraph orders in the Greek...

  4. 46 CFR 402.220 - Registration of pilots.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... in search and rescue and civil defense procedures as issued by the U.S. Coast Guard, Federal, State, and local port authorities. (5) Instruction in basic helm and engine telegraph orders in the Greek...

  5. The ANACONDA algorithm for deformable image registration in radiotherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Weistrand, Ola; Svensson, Stina, E-mail: stina.svensson@raysearchlabs.com

    2015-01-15

    Purpose: The purpose of this work was to describe a versatile algorithm for deformable image registration with applications in radiotherapy and to validate it on thoracic 4DCT data as well as CT/cone beam CT (CBCT) data. Methods: ANAtomically CONstrained Deformation Algorithm (ANACONDA) combines image information (i.e., intensities) with anatomical information as provided by contoured image sets. The registration problem is formulated as a nonlinear optimization problem and solved with an in-house developed solver, tailored to this problem. The objective function, which is minimized during optimization, is a linear combination of four nonlinear terms: 1. image similarity term; 2. grid regularizationmore » term, which aims at keeping the deformed image grid smooth and invertible; 3. a shape based regularization term which works to keep the deformation anatomically reasonable when regions of interest are present in the reference image; and 4. a penalty term which is added to the optimization problem when controlling structures are used, aimed at deforming the selected structure in the reference image to the corresponding structure in the target image. Results: To validate ANACONDA, the authors have used 16 publically available thoracic 4DCT data sets for which target registration errors from several algorithms have been reported in the literature. On average for the 16 data sets, the target registration error is 1.17 ± 0.87 mm, Dice similarity coefficient is 0.98 for the two lungs, and image similarity, measured by the correlation coefficient, is 0.95. The authors have also validated ANACONDA using two pelvic cases and one head and neck case with planning CT and daily acquired CBCT. Each image has been contoured by a physician (radiation oncologist) or experienced radiation therapist. The results are an improvement with respect to rigid registration. However, for the head and neck case, the sample set is too small to show statistical significance. Conclusions: ANACONDA performs well in comparison with other algorithms. By including CT/CBCT data in the validation, the various aspects of the algorithm such as its ability to handle different modalities, large deformations, and air pockets are shown.« less

  6. Registration of T2-weighted and diffusion-weighted MR images of the prostate: comparison between manual and landmark-based methods

    NASA Astrophysics Data System (ADS)

    Peng, Yahui; Jiang, Yulei; Soylu, Fatma N.; Tomek, Mark; Sensakovic, William; Oto, Aytekin

    2012-02-01

    Quantitative analysis of multi-parametric magnetic resonance (MR) images of the prostate, including T2-weighted (T2w) and diffusion-weighted (DW) images, requires accurate image registration. We compared two registration methods between T2w and DW images. We collected pre-operative MR images of 124 prostate cancer patients (68 patients scanned with a GE scanner and 56 with Philips scanners). A landmark-based rigid registration was done based on six prostate landmarks in both T2w and DW images identified by a radiologist. Independently, a researcher manually registered the same images. A radiologist visually evaluated the registration results by using a 5-point ordinal scale of 1 (worst) to 5 (best). The Wilcoxon signed-rank test was used to determine whether the radiologist's ratings of the results of the two registration methods were significantly different. Results demonstrated that both methods were accurate: the average ratings were 4.2, 3.3, and 3.8 for GE, Philips, and all images, respectively, for the landmark-based method; and 4.6, 3.7, and 4.2, respectively, for the manual method. The manual registration results were more accurate than the landmark-based registration results (p < 0.0001 for GE, Philips, and all images). Therefore, the manual method produces more accurate registration between T2w and DW images than the landmark-based method.

  7. 76 FR 64960 - Extension of Agency Information Collection Activity Under OMB Review: Flight Crew Self-Defense...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-10-19

    ... Information Collection Activity Under OMB Review: Flight Crew Self-Defense Training--Registration and... self-defense training class provided by TSA, the collection process involves requesting, the name.... Information Collection Requirement Title: Flight Crew Self-Defense Training--Registration and Evaluation. Type...

  8. A REGIONAL APPROACH TO ECOLOGICAL RISK ASSESSMENTS FOR PESTICIDE REGISTRATION

    EPA Science Inventory

    Currently, most ecological risk assessments for EPA pesticide registration are evaluated at the national scale using a predetermined list of test species (OPPTS 850.4225 and 8504250) as a model system with little regard to where and how the product will ultimately be used. The a...

  9. 78 FR 24195 - Product Cancellation Order for Certain Pesticide Registrations

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-04-24

    ... Insecticide, Fungicide, and Rodenticide Act (FIFRA). This cancellation order follows a December 19, 2012... effective December 31, 2016. FOR FURTHER INFORMATION CONTACT: Molly Clayton, Pesticide Re-Evaluation... registrants of the products in Tables 1. and 2. of this unit, in sequence by EPA company number. This number...

  10. 76 FR 57058 - International Cooperation on Harmonisation of Technical Requirements for Registration of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-09-15

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2010-D-0165] International Cooperation on Harmonisation of Technical Requirements for Registration of Veterinary Medicinal Products; Guidance for Industry on Studies To Evaluate the Metabolism and Residue Kinetics of Veterinary...

  11. [Consideration about chemistry, manufacture and control (CMC) key problems in simplified registration of classical traditional Chinese medicine excellent prescriptions].

    PubMed

    Wang, Zhi-Min; Liu, Ju-Yan; Liu, Xiao-Qian; Wang, De-Qin; Yan, Li-Hua; Zhu, Jin-Jin; Gao, Hui-Min; Li, Chun; Wang, Jin-Yu; Li, Chu-Yuan; Ni, Qing-Chun; Huang, Ji-Sheng; Lin, Juan

    2017-05-01

    As an outstanding representative of traditional Chinese medicine(TCM) prescriptions accumulated from famous TCM doctors' clinical experiences in past dynasties, classical TCM excellent prescriptions (cTCMeP) are the most valuable part of TCM system. To support the research and development of cTCMeP, a series of regulations and measures were issued to encourage its simplified registration. There is still a long-way to go because many key problems and puzzles about technology, registration and administration in cTCMeP R&D process are not resolved. Based on the analysis of registration and management regulations of botanical drug products in FDA of USA and Japan, and EMA of Europe, the possible key problems and countermeasures in chemistry, manufacture and control (CMC) of simplified registration of cTCMeP were analyzed on the consideration of its actual situation. The method of "reference decoction extract by traditional prescription" (RDETP) was firstly proposed as standard to evaluate the quality and preparation uniformity between the new developing product under simplified registration and traditional original usages of cTCMeP, instead of Standard Decoction method in Japan. "Totality of the evidence" approach, mass balance and bioassay/biological assay of cTCMeP were emphatically suggested to introduce to the quality uniformity evaluation system in the raw drug material, drug substance and final product between the modern product and traditional decoction. Copyright© by the Chinese Pharmaceutical Association.

  12. Toward magnetic resonance-guided electroanatomical voltage mapping for catheter ablation of scar-related ventricular tachycardia: a comparison of registration methods.

    PubMed

    Tao, Qian; Milles, Julien; VAN Huls VAN Taxis, Carine; Lamb, Hildo J; Reiber, Johan H C; Zeppenfeld, Katja; VAN DER Geest, Rob J

    2012-01-01

    Integration of preprocedural delayed enhanced magnetic resonance imaging (DE-MRI) with electroanatomical voltage mapping (EAVM) may provide additional high-resolution substrate information for catheter ablation of scar-related ventricular tachycardias (VT). Accurate and fast image integration of DE-MRI with EAVM is desirable for MR-guided ablation. Twenty-six VT patients with large transmural scar underwent catheter ablation and preprocedural DE-MRI. With different registration models and EAVM input, 3 image integration methods were evaluated and compared to the commercial registration module CartoMerge. The performance was evaluated both in terms of distance measure that describes surface matching, and correlation measure that describes actual scar correspondence. Compared to CartoMerge, the method that uses the translation-and-rotation model and high-density EAVM input resulted in a registration error of 4.32±0.69 mm as compared to 4.84 ± 1.07 (P <0.05); the method that uses the translation model and high-density EAVM input resulted in a registration error of 4.60 ± 0.65 mm (P = NS); and the method that uses the translation model and a single anatomical landmark input resulted in a registration error of 6.58 ± 1.63 mm (P < 0.05). No significant difference in scar correlation was observed between all 3 methods and CartoMerge (P = NS). During VT ablation procedures, accurate integration of EAVM and DE-MRI can be achieved using a translation registration model and a single anatomical landmark. This model allows for image integration in minimal mapping time and is likely to reduce fluoroscopy time and increase procedure efficacy. © 2011 Wiley Periodicals, Inc.

  13. Automatic Masking for Robust 3D-2D Image Registration in Image-Guided Spine Surgery.

    PubMed

    Ketcha, M D; De Silva, T; Uneri, A; Kleinszig, G; Vogt, S; Wolinsky, J-P; Siewerdsen, J H

    During spinal neurosurgery, patient-specific information, planning, and annotation such as vertebral labels can be mapped from preoperative 3D CT to intraoperative 2D radiographs via image-based 3D-2D registration. Such registration has been shown to provide a potentially valuable means of decision support in target localization as well as quality assurance of the surgical product. However, robust registration can be challenged by mismatch in image content between the preoperative CT and intraoperative radiographs, arising, for example, from anatomical deformation or the presence of surgical tools within the radiograph. In this work, we develop and evaluate methods for automatically mitigating the effect of content mismatch by leveraging the surgical planning data to assign greater weight to anatomical regions known to be reliable for registration and vital to the surgical task while removing problematic regions that are highly deformable or often occluded by surgical tools. We investigated two approaches to assigning variable weight (i.e., "masking") to image content and/or the similarity metric: (1) masking the preoperative 3D CT ("volumetric masking"); and (2) masking within the 2D similarity metric calculation ("projection masking"). The accuracy of registration was evaluated in terms of projection distance error (PDE) in 61 cases selected from an IRB-approved clinical study. The best performing of the masking techniques was found to reduce the rate of gross failure (PDE > 20 mm) from 11.48% to 5.57% in this challenging retrospective data set. These approaches provided robustness to content mismatch and eliminated distinct failure modes of registration. Such improvement was gained without additional workflow and has motivated incorporation of the masking methods within a system under development for prospective clinical studies.

  14. A fast and mobile system for registration of low-altitude visual and thermal aerial images using multiple small-scale UAVs

    NASA Astrophysics Data System (ADS)

    Yahyanejad, Saeed; Rinner, Bernhard

    2015-06-01

    The use of multiple small-scale UAVs to support first responders in disaster management has become popular because of their speed and low deployment costs. We exploit such UAVs to perform real-time monitoring of target areas by fusing individual images captured from heterogeneous aerial sensors. Many approaches have already been presented to register images from homogeneous sensors. These methods have demonstrated robustness against scale, rotation and illumination variations and can also cope with limited overlap among individual images. In this paper we focus on thermal and visual image registration and propose different methods to improve the quality of interspectral registration for the purpose of real-time monitoring and mobile mapping. Images captured by low-altitude UAVs represent a very challenging scenario for interspectral registration due to the strong variations in overlap, scale, rotation, point of view and structure of such scenes. Furthermore, these small-scale UAVs have limited processing and communication power. The contributions of this paper include (i) the introduction of a feature descriptor for robustly identifying corresponding regions of images in different spectrums, (ii) the registration of image mosaics, and (iii) the registration of depth maps. We evaluated the first method using a test data set consisting of 84 image pairs. In all instances our approach combined with SIFT or SURF feature-based registration was superior to the standard versions. Although we focus mainly on aerial imagery, our evaluation shows that the presented approach would also be beneficial in other scenarios such as surveillance and human detection. Furthermore, we demonstrated the advantages of the other two methods in case of multiple image pairs.

  15. Automatic masking for robust 3D-2D image registration in image-guided spine surgery

    NASA Astrophysics Data System (ADS)

    Ketcha, M. D.; De Silva, T.; Uneri, A.; Kleinszig, G.; Vogt, S.; Wolinsky, J.-P.; Siewerdsen, J. H.

    2016-03-01

    During spinal neurosurgery, patient-specific information, planning, and annotation such as vertebral labels can be mapped from preoperative 3D CT to intraoperative 2D radiographs via image-based 3D-2D registration. Such registration has been shown to provide a potentially valuable means of decision support in target localization as well as quality assurance of the surgical product. However, robust registration can be challenged by mismatch in image content between the preoperative CT and intraoperative radiographs, arising, for example, from anatomical deformation or the presence of surgical tools within the radiograph. In this work, we develop and evaluate methods for automatically mitigating the effect of content mismatch by leveraging the surgical planning data to assign greater weight to anatomical regions known to be reliable for registration and vital to the surgical task while removing problematic regions that are highly deformable or often occluded by surgical tools. We investigated two approaches to assigning variable weight (i.e., "masking") to image content and/or the similarity metric: (1) masking the preoperative 3D CT ("volumetric masking"); and (2) masking within the 2D similarity metric calculation ("projection masking"). The accuracy of registration was evaluated in terms of projection distance error (PDE) in 61 cases selected from an IRB-approved clinical study. The best performing of the masking techniques was found to reduce the rate of gross failure (PDE > 20 mm) from 11.48% to 5.57% in this challenging retrospective data set. These approaches provided robustness to content mismatch and eliminated distinct failure modes of registration. Such improvement was gained without additional workflow and has motivated incorporation of the masking methods within a system under development for prospective clinical studies.

  16. Comparative study to evaluate the accuracy of polyether occlusal bite registration material and occlusal registration wax as a guide for occlusal reduction during tooth preparation.

    PubMed

    Joshi, Niranjan; Shetty, Sridhar N; Prasad, Krishna D

    2013-01-01

    The use of different materials and techniques has been studied to decide the safest quantum of reduction of the occlusal surfaces. However, these methods provide limited information as to the actual amount of reduction with limitations in accuracy, accessibility and complexity. The objective of this study was to compare and evaluate the reliability of the most commonly used occlusal registration wax that with polyether bite registration material as a guide for occlusal reduction required during tooth preparations. For the purpose of this study, 25 abutment teeth requiring tooth preparation for fixed prosthesis were selected and tooth preparations carried out. Modeling wax strips of specific dimensions were placed onto the cast of prepared tooth, which was mounted on maximum intercuspation on the articulator and the articulator was closed. The thickness of the wax registration was measured at three zones namely two functional cusps and central fossa. Similar measurements were made using the polyether bite registration material and prosthesis at the same zones. The data was tabulated and was subjected to statistical analysis using anova test and Tukey honestly significant difference test. The differences in thickness between wax record and prosthesis by 0.1346 mm, whereas the difference between polyether and prosthesis was 0.02 mm with a P value of 0.042, which is statistically significant. This means that the wax record was 8.25% larger than the prosthesis while polyether was just 1.27% larger than the prosthesis. The clinical significance of the above analysis is that Ramitec polyether bite registration material is most suitable material when compared with commonly used modeling wax during the tooth preparation.

  17. Registration of angiographic image on real-time fluoroscopic image for image-guided percutaneous coronary intervention.

    PubMed

    Kim, Dongkue; Park, Sangsoo; Jeong, Myung Ho; Ryu, Jeha

    2018-02-01

    In percutaneous coronary intervention (PCI), cardiologists must study two different X-ray image sources: a fluoroscopic image and an angiogram. Manipulating a guidewire while alternately monitoring the two separate images on separate screens requires a deep understanding of the anatomy of coronary vessels and substantial training. We propose 2D/2D spatiotemporal image registration of the two images in a single image in order to provide cardiologists with enhanced visual guidance in PCI. The proposed 2D/2D spatiotemporal registration method uses a cross-correlation of two ECG series in each image to temporally synchronize two separate images and register an angiographic image onto the fluoroscopic image. A guidewire centerline is then extracted from the fluoroscopic image in real time, and the alignment of the centerline with vessel outlines of the chosen angiographic image is optimized using the iterative closest point algorithm for spatial registration. A proof-of-concept evaluation with a phantom coronary vessel model with engineering students showed an error reduction rate greater than 74% on wrong insertion to nontarget branches compared to the non-registration method and more than 47% reduction in the task completion time in performing guidewire manipulation for very difficult tasks. Evaluation with a small number of experienced doctors shows a potentially significant reduction in both task completion time and error rate for difficult tasks. The total registration time with real procedure X-ray (angiographic and fluoroscopic) images takes [Formula: see text] 60 ms, which is within the fluoroscopic image acquisition rate of 15 Hz. By providing cardiologists with better visual guidance in PCI, the proposed spatiotemporal image registration method is shown to be useful in advancing the guidewire to the coronary vessel branches, especially those difficult to insert into.

  18. A Multistage Approach for Image Registration.

    PubMed

    Bowen, Francis; Hu, Jianghai; Du, Eliza Yingzi

    2016-09-01

    Successful image registration is an important step for object recognition, target detection, remote sensing, multimodal content fusion, scene blending, and disaster assessment and management. The geometric and photometric variations between images adversely affect the ability for an algorithm to estimate the transformation parameters that relate the two images. Local deformations, lighting conditions, object obstructions, and perspective differences all contribute to the challenges faced by traditional registration techniques. In this paper, a novel multistage registration approach is proposed that is resilient to view point differences, image content variations, and lighting conditions. Robust registration is realized through the utilization of a novel region descriptor which couples with the spatial and texture characteristics of invariant feature points. The proposed region descriptor is exploited in a multistage approach. A multistage process allows the utilization of the graph-based descriptor in many scenarios thus allowing the algorithm to be applied to a broader set of images. Each successive stage of the registration technique is evaluated through an effective similarity metric which determines subsequent action. The registration of aerial and street view images from pre- and post-disaster provide strong evidence that the proposed method estimates more accurate global transformation parameters than traditional feature-based methods. Experimental results show the robustness and accuracy of the proposed multistage image registration methodology.

  19. A quantitative comparison of the performance of three deformable registration algorithms in radiotherapy

    PubMed Central

    Fabri, Daniella; Zambrano, Valentina; Bhatia, Amon; Furtado, Hugo; Bergmann, Helmar; Stock, Markus; Bloch, Christoph; Lütgendorf-Caucig, Carola; Pawiro, Supriyanto; Georg, Dietmar; Birkfellner, Wolfgang; Figl, Michael

    2013-01-01

    We present an evaluation of various non-rigid registration algorithms for the purpose of compensating interfractional motion of the target volume and organs at risk areas when acquiring CBCT image data prior to irradiation. Three different deformable registration (DR) methods were used: the Demons algorithm implemented in the iPlan Software (BrainLAB AG, Feldkirchen, Germany) and two custom-developed piecewise methods using either a Normalized Correlation or a Mutual Information metric (featureletNC and featureletMI). These methods were tested on data acquired using a novel purpose-built phantom for deformable registration and clinical CT/CBCT data of prostate and lung cancer patients. The Dice similarity coefficient (DSC) between manually drawn contours and the contours generated by a derived deformation field of the structures in question was compared to the result obtained with rigid registration (RR). For the phantom, the piecewise methods were slightly superior, the featureletNC for the intramodality and the featureletMI for the intermodality registrations. For the prostate cases in less than 50% of the images studied the DSC was improved over RR. Deformable registration methods improved the outcome over a rigid registration for lung cases and in the phantom study, but not in a significant way for the prostate study. A significantly superior deformation method could not be identified. PMID:23969092

  20. SU-F-BRA-01: A Procedure for the Fast Semi-Automatic Localization of Catheters Using An Electromagnetic Tracker (EMT) for Image-Guided Brachytherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Damato, A; Viswanathan, A; Cormack, R

    2015-06-15

    Purpose: To evaluate the feasibility of brachytherapy catheter localization through use of an EMT and 3D image set. Methods: A 15-catheter phantom mimicking an interstitial implantation was built and CT-scanned. Baseline catheter reconstruction was performed manually. An EMT was used to acquire the catheter coordinates in the EMT frame of reference. N user-identified catheter tips, without catheter number associations, were used to establish registration with the CT frame of reference. Two algorithms were investigated: brute-force registration (BFR), in which all possible permutation of N identified tips with the EMT tips were evaluated; and signature-based registration (SBR), in which a distancemore » matrix was used to generate a list of matching signatures describing possible N-point matches with the registration points. Digitization error (average of the distance between corresponding EMT and baseline dwell positions; average, standard deviation, and worst-case scenario over all possible registration-point selections) and algorithm inefficiency (maximum number of rigid registrations required to find the matching fusion for all possible selections of registration points) were calculated. Results: Digitization errors on average <2 mm were observed for N ≥5, with standard deviation <2 mm for N ≥6, and worst-case scenario error <2 mm for N ≥11. Algorithm inefficiencies were: N = 5, 32,760 (BFR) and 9900 (SBR); N = 6, 360,360 (BFR) and 21,660 (SBR); N = 11, 5.45*1010 (BFR) and 12 (SBR). Conclusion: A procedure was proposed for catheter reconstruction using EMT and only requiring user identification of catheter tips without catheter localization. Digitization errors <2 mm were observed on average with 5 or more registration points, and in any scenario with 11 or more points. Inefficiency for N = 11 was 9 orders of magnitude lower for SBR than for BFR. Funding: Kaye Family Award.« less

  1. 75 FR 48608 - Schedule of Fees Authorized by 49 U.S.C. 30141

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-08-11

    ... [Docket No. NHTSA 2010-0035; Notice 2] RIN 2127-AK70 Schedule of Fees Authorized by 49 U.S.C. 30141 AGENCY....C. 30141, relating to the registration of importers and the importation of motor vehicles not... to initiate rulemaking pursuant to 49 U.S.C. Chapter 301. The petition must contain a brief statement...

  2. Registration of Medical Devices

    PubMed Central

    George, Bobby

    2010-01-01

    Globally the medical device (MD) market has been growing quite rapidly over the past decade. The regulatory framework for pharmaceuticals and devices differ substantially. The regulatory authorities in different regions of the world recognize different classes of medical devices (MDs), based on their design complexity, their use characteristics, and their potential for harm, if misused. With the vast majority of MDs in developing countries being imported, the respective governments need to put in place policies & regulations to address all elements related to MDs, ranging from its development, manufacturing, registration to post-marketing obligations & disposal so that public can have access to high quality, safe & affordable products for appropriate use. This article highlights current regulations pertaining to registration of MDs in India, in light of those existing in Global Harmonization Task Force (GHTF) member countries & Association of Southeast Asian Nations (ASEAN) countries. PMID:21814626

  3. larvalign: Aligning Gene Expression Patterns from the Larval Brain of Drosophila melanogaster.

    PubMed

    Muenzing, Sascha E A; Strauch, Martin; Truman, James W; Bühler, Katja; Thum, Andreas S; Merhof, Dorit

    2018-01-01

    The larval brain of the fruit fly Drosophila melanogaster is a small, tractable model system for neuroscience. Genes for fluorescent marker proteins can be expressed in defined, spatially restricted neuron populations. Here, we introduce the methods for 1) generating a standard template of the larval central nervous system (CNS), 2) spatial mapping of expression patterns from different larvae into a reference space defined by the standard template. We provide a manually annotated gold standard that serves for evaluation of the registration framework involved in template generation and mapping. A method for registration quality assessment enables the automatic detection of registration errors, and a semi-automatic registration method allows one to correct registrations, which is a prerequisite for a high-quality, curated database of expression patterns. All computational methods are available within the larvalign software package: https://github.com/larvalign/larvalign/releases/tag/v1.0.

  4. An effective non-rigid registration approach for ultrasound image based on "demons" algorithm.

    PubMed

    Liu, Yan; Cheng, H D; Huang, Jianhua; Zhang, Yingtao; Tang, Xianglong; Tian, Jiawei

    2013-06-01

    Medical image registration is an important component of computer-aided diagnosis system in diagnostics, therapy planning, and guidance of surgery. Because of its low signal/noise ratio (SNR), ultrasound (US) image registration is a difficult task. In this paper, a fully automatic non-rigid image registration algorithm based on demons algorithm is proposed for registration of ultrasound images. In the proposed method, an "inertia force" derived from the local motion trend of pixels in a Moore neighborhood system is produced and integrated into optical flow equation to estimate the demons force, which is helpful to handle the speckle noise and preserve the geometric continuity of US images. In the experiment, a series of US images and several similarity measure metrics are utilized for evaluating the performance. The experimental results demonstrate that the proposed method can register ultrasound images efficiently, robust to noise, quickly and automatically.

  5. Image registration assessment in radiotherapy image guidance based on control chart monitoring.

    PubMed

    Xia, Wenyao; Breen, Stephen L

    2018-04-01

    Image guidance with cone beam computed tomography in radiotherapy can guarantee the precision and accuracy of patient positioning prior to treatment delivery. During the image guidance process, operators need to take great effort to evaluate the image guidance quality before correcting a patient's position. This work proposes an image registration assessment method based on control chart monitoring to reduce the effort taken by the operator. According to the control chart plotted by daily registration scores of each patient, the proposed method can quickly detect both alignment errors and image quality inconsistency. Therefore, the proposed method can provide a clear guideline for the operators to identify unacceptable image quality and unacceptable image registration with minimal effort. Experimental results demonstrate that by using control charts from a clinical database of 10 patients undergoing prostate radiotherapy, the proposed method can quickly identify out-of-control signals and find special cause of out-of-control registration events.

  6. A Mating of Tarantulas

    ERIC Educational Resources Information Center

    Lewis, Robert L.

    1978-01-01

    The role of the trustee in interinstitutional cooperation is discussed. Benefits include: plant facilities sharing, joint credit unions, library exchange, joint health care facilities, joint counseling, joint apprenticeship programs, cross registration, faculty exchange joint appointments, etc. (Author/LBH)

  7. American Academy of Forensic Sciences

    MedlinePlus

    ... Academy News PDF Library Proceedings Journal of Forensic Sciences Information for Authors Searchable Index Contact Information Forensic Links ... Dale Stewart Award 2018 Annual Scientific Meeting Registration ... in Forensic Science … Now What? Young Forensic Scientists Forum (YFSF) Annual ...

  8. 75 FR 69705 - Importer of Controlled Substances; Notice of Application

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-11-15

    ... re-registration to import crude opium, poppy straw, concentrate of poppy straw, and coca leaves. As... classes of controlled substances listed in schedule I or II, which fall under the authority of section...

  9. Online education about herbs and dietary supplements: margin or mission?

    PubMed

    Kemper, Kathi J; Patel, Sejal

    2015-01-01

    Online education is increasingly used to train health professionals, but little is known about how variations in cost affect use of elective training. We assessed whether offering registration for free increased the number of modules consumed in both absolute terms (# modules consumed per person, pp) and relative terms (# modules consumed per # modules registered). We analyzed results of the 'natural experiment' on learner's use of the OSU Center for Integrative Health and Wellness online elective curriculum, Introduction Herbs and Dietary Supplements Across the Lifespan, in which costs varied based on monthly discounts for students, faculty, staff, alumni, and members of selected professional associations. Over 7 months there were a total of 905 registrants for 8553 modules. Most (847/905, 94%) registered for free; they completed 1505 (18%) of 8344 modules for which they registered. Fewer (58/905, 6%) people paid for registration; they completed a significantly higher percentage 90/209 (43%, P < 0.001) of modules for which they registered; those who paid full, non-discount rates had the highest completion rates (62%, P < 0.001). Free and paid registrants completed about the same average number of modules per person, pp, (1.8 pp free vs.1.6 pp paid). Although it may not contribute to financial margins, offering free online elective training addresses the institutional mission of increasing the number health professionals trained and the number of modules consumed compared with charging for training. Additional research is needed to determine the impact of pricing on educational outcomes and ultimately on patient care. © The Author(s) 2014.

  10. Evaluation of body-wise and organ-wise registrations for abdominal organs

    NASA Astrophysics Data System (ADS)

    Xu, Zhoubing; Panjwani, Sahil A.; Lee, Christopher P.; Burke, Ryan P.; Baucom, Rebeccah B.; Poulose, Benjamin K.; Abramson, Richard G.; Landman, Bennett A.

    2016-03-01

    Identifying cross-sectional and longitudinal correspondence in the abdomen on computed tomography (CT) scans is necessary for quantitatively tracking change and understanding population characteristics, yet abdominal image registration is a challenging problem. The key difficulty in solving this problem is huge variations in organ dimensions and shapes across subjects. The current standard registration method uses the global or body-wise registration technique, which is based on the global topology for alignment. This method (although producing decent results) has substantial influence of outliers, thus leaving room for significant improvement. Here, we study a new image registration approach using local (organ-wise registration) by first creating organ-specific bounding boxes and then using these regions of interest (ROIs) for aligning references to target. Based on Dice Similarity Coefficient (DSC), Mean Surface Distance (MSD) and Hausdorff Distance (HD), the organ-wise approach is demonstrated to have significantly better results by minimizing the distorting effects of organ variations. This paper compares exclusively the two registration methods by providing novel quantitative and qualitative comparison data and is a subset of the more comprehensive problem of improving the multi-atlas segmentation by using organ normalization.

  11. Marker-free registration for the accurate integration of CT images and the subject's anatomy during navigation surgery of the maxillary sinus

    PubMed Central

    Kang, S-H; Kim, M-K; Kim, J-H; Park, H-K; Park, W

    2012-01-01

    Objective This study compared three marker-free registration methods that are applicable to a navigation system that can be used for maxillary sinus surgery, and evaluated the associated errors, with the aim of determining which registration method is the most applicable for operations that require accurate navigation. Methods The CT digital imaging and communications in medicine (DICOM) data of ten maxillary models in DICOM files were converted into stereolithography file format. All of the ten maxillofacial models were scanned three dimensionally using a light-based three-dimensional scanner. The methods applied for registration of the maxillofacial models utilized the tooth cusp, bony landmarks and maxillary sinus anterior wall area. The errors during registration were compared between the groups. Results There were differences between the three registration methods in the zygoma, sinus posterior wall, molar alveolar, premolar alveolar, lateral nasal aperture and the infraorbital areas. The error was smallest using the overlay method for the anterior wall of the maxillary sinus, and the difference was statistically significant. Conclusion The navigation error can be minimized by conducting registration using the anterior wall of the maxillary sinus during image-guided surgery of the maxillary sinus. PMID:22499127

  12. MARS: a mouse atlas registration system based on a planar x-ray projector and an optical camera

    NASA Astrophysics Data System (ADS)

    Wang, Hongkai; Stout, David B.; Taschereau, Richard; Gu, Zheng; Vu, Nam T.; Prout, David L.; Chatziioannou, Arion F.

    2012-10-01

    This paper introduces a mouse atlas registration system (MARS), composed of a stationary top-view x-ray projector and a side-view optical camera, coupled to a mouse atlas registration algorithm. This system uses the x-ray and optical images to guide a fully automatic co-registration of a mouse atlas with each subject, in order to provide anatomical reference for small animal molecular imaging systems such as positron emission tomography (PET). To facilitate the registration, a statistical atlas that accounts for inter-subject anatomical variations was constructed based on 83 organ-labeled mouse micro-computed tomography (CT) images. The statistical shape model and conditional Gaussian model techniques were used to register the atlas with the x-ray image and optical photo. The accuracy of the atlas registration was evaluated by comparing the registered atlas with the organ-labeled micro-CT images of the test subjects. The results showed excellent registration accuracy of the whole-body region, and good accuracy for the brain, liver, heart, lungs and kidneys. In its implementation, the MARS was integrated with a preclinical PET scanner to deliver combined PET/MARS imaging, and to facilitate atlas-assisted analysis of the preclinical PET images.

  13. MARS: a mouse atlas registration system based on a planar x-ray projector and an optical camera.

    PubMed

    Wang, Hongkai; Stout, David B; Taschereau, Richard; Gu, Zheng; Vu, Nam T; Prout, David L; Chatziioannou, Arion F

    2012-10-07

    This paper introduces a mouse atlas registration system (MARS), composed of a stationary top-view x-ray projector and a side-view optical camera, coupled to a mouse atlas registration algorithm. This system uses the x-ray and optical images to guide a fully automatic co-registration of a mouse atlas with each subject, in order to provide anatomical reference for small animal molecular imaging systems such as positron emission tomography (PET). To facilitate the registration, a statistical atlas that accounts for inter-subject anatomical variations was constructed based on 83 organ-labeled mouse micro-computed tomography (CT) images. The statistical shape model and conditional Gaussian model techniques were used to register the atlas with the x-ray image and optical photo. The accuracy of the atlas registration was evaluated by comparing the registered atlas with the organ-labeled micro-CT images of the test subjects. The results showed excellent registration accuracy of the whole-body region, and good accuracy for the brain, liver, heart, lungs and kidneys. In its implementation, the MARS was integrated with a preclinical PET scanner to deliver combined PET/MARS imaging, and to facilitate atlas-assisted analysis of the preclinical PET images.

  14. Estimation of Mouse Organ Locations Through Registration of a Statistical Mouse Atlas With Micro-CT Images

    PubMed Central

    Stout, David B.; Chatziioannou, Arion F.

    2012-01-01

    Micro-CT is widely used in preclinical studies of small animals. Due to the low soft-tissue contrast in typical studies, segmentation of soft tissue organs from noncontrast enhanced micro-CT images is a challenging problem. Here, we propose an atlas-based approach for estimating the major organs in mouse micro-CT images. A statistical atlas of major trunk organs was constructed based on 45 training subjects. The statistical shape model technique was used to include inter-subject anatomical variations. The shape correlations between different organs were described using a conditional Gaussian model. For registration, first the high-contrast organs in micro-CT images were registered by fitting the statistical shape model, while the low-contrast organs were subsequently estimated from the high-contrast organs using the conditional Gaussian model. The registration accuracy was validated based on 23 noncontrast-enhanced and 45 contrast-enhanced micro-CT images. Three different accuracy metrics (Dice coefficient, organ volume recovery coefficient, and surface distance) were used for evaluation. The Dice coefficients vary from 0.45 ± 0.18 for the spleen to 0.90 ± 0.02 for the lungs, the volume recovery coefficients vary from for the liver to 1.30 ± 0.75 for the spleen, the surface distances vary from 0.18 ± 0.01 mm for the lungs to 0.72 ± 0.42 mm for the spleen. The registration accuracy of the statistical atlas was compared with two publicly available single-subject mouse atlases, i.e., the MOBY phantom and the DIGIMOUSE atlas, and the results proved that the statistical atlas is more accurate than the single atlases. To evaluate the influence of the training subject size, different numbers of training subjects were used for atlas construction and registration. The results showed an improvement of the registration accuracy when more training subjects were used for the atlas construction. The statistical atlas-based registration was also compared with the thin-plate spline based deformable registration, commonly used in mouse atlas registration. The results revealed that the statistical atlas has the advantage of improving the estimation of low-contrast organs. PMID:21859613

  15. Improved multimodality data fusion of late gadolinium enhancement MRI to left ventricular voltage maps in ventricular tachycardia ablation.

    PubMed

    Roujol, Sebastien; Basha, Tamer A; Tan, Alex; Khanna, Varun; Chan, Raymond H; Moghari, Mehdi H; Rayatzadeh, Hussein; Shaw, Jaime L; Josephson, Mark E; Nezafat, Reza

    2013-05-01

    Electroanatomical voltage mapping (EAVM) is commonly performed prior to catheter ablation of scar-related ventricular tachycardia (VT) to locate the arrhythmic substrate and to guide the ablation procedure. EAVM is used to locate the position of the ablation catheter and to provide a 3-D reconstruction of left-ventricular anatomy and scar. However, EAVM measurements only represent the endocardial scar with no transmural or epicardial information. Furthermore, EAVM is a time-consuming procedure, with a high operator dependence and has low sampling density, i.e., spatial resolution. Late gadolinium enhancement (LGE) magnetic resonance imaging (MRI) allows noninvasive assessment of scar morphology that can depict 3-D scar architecture. Despite the potential use of LGE as a roadmap for VT ablation for identification of arrhythmogenic substrate, its utility has been very limited. To allow for identification of VT substrate, a correlation is needed between the substrates identified by EAVM as the gold standard and LGE-MRI scar characteristics. To do so, a system must be developed to fuse the datasets from these modalities. In this study, a registration pipeline for the fusion of LGE-MRI and EAVM data is presented. A novel surface registration algorithm is proposed, integrating the matching of global scar areas as an additional constraint in the registration process. A preparatory landmark registration is initially performed to expedite the convergence of the algorithm. Numerical simulations were performed to evaluate the accuracy of the registration in the presence of errors in identifying landmarks in EAVM or LGE-MRI datasets as well as additional errors due to respiratory or cardiac motion. Subsequently, the accuracy of the proposed fusion system was evaluated in a cohort of ten patients undergoing VT ablation where both EAVM and LGE-MRI data were available. Compared to landmark registration and surface registration, the presented method achieved significant improvement in registration error. The proposed data fusion system allows the fusion of EAVM and LGE-MRI data in VT ablation with registration errors less than 3.5  mm.

  16. WE-AB-BRA-01: 3D-2D Image Registration for Target Localization in Spine Surgery: Comparison of Similarity Metrics Against Robustness to Content Mismatch

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    De Silva, T; Ketcha, M; Siewerdsen, J H

    Purpose: In image-guided spine surgery, mapping 3D preoperative images to 2D intraoperative images via 3D-2D registration can provide valuable assistance in target localization. However, the presence of surgical instrumentation, hardware implants, and soft-tissue resection/displacement causes mismatches in image content, confounding existing registration methods. Manual/semi-automatic methods to mask such extraneous content is time consuming, user-dependent, error prone, and disruptive to clinical workflow. We developed and evaluated 2 novel similarity metrics within a robust registration framework to overcome such challenges in target localization. Methods: An IRB-approved retrospective study in 19 spine surgery patients included 19 preoperative 3D CT images and 50 intraoperativemore » mobile radiographs in cervical, thoracic, and lumbar spine regions. A neuroradiologist provided truth definition of vertebral positions in CT and radiography. 3D-2D registration was performed using the CMA-ES optimizer with 4 gradient-based image similarity metrics: (1) gradient information (GI); (2) gradient correlation (GC); (3) a novel variant referred to as gradient orientation (GO); and (4) a second variant referred to as truncated gradient correlation (TGC). Registration accuracy was evaluated in terms of the projection distance error (PDE) of the vertebral levels. Results: Conventional similarity metrics were susceptible to gross registration error and failure modes associated with the presence of surgical instrumentation: for GI, the median PDE and interquartile range was 33.0±43.6 mm; similarly for GC, PDE = 23.0±92.6 mm respectively. The robust metrics GO and TGC, on the other hand, demonstrated major improvement in PDE (7.6 ±9.4 mm and 8.1± 18.1 mm, respectively) and elimination of gross failure modes. Conclusion: The proposed GO and TGC similarity measures improve registration accuracy and robustness to gross failure in the presence of strong image content mismatch. Such registration capability could offer valuable assistance in target localization without disruption of clinical workflow. G. Kleinszig and S. Vogt are employees of Siemens Healthcare.« less

  17. Can the UK's birth registration system better serve the interests of those born following collaborative assisted reproduction?

    PubMed

    Crawshaw, Marilyn A; Blyth, Eric D; Feast, Julia

    2017-06-01

    Current birth registration systems fail to serve adequately the interests of those born as a result of gamete and embryo donation and surrogacy. In the UK, changes to the birth registration system have been piecemeal, reactive and situation-specific and no information is recorded about gamete donors. Birth registration has thereby become a statement of legal parentage and citizenship only, without debate as to whether it should serve any wider functions. This sits uneasily with the increasingly accepted human right to know one's genetic and gestational as well as legal parents, and the duty of the State to facilitate that right. This commentary sets out one possible model for reform to better ensure that those affected become aware of, and/or have access to, knowledge about their origins and that such information is stored and released effectively without compromising individual privacy. Among other features, our proposal links the birth registration system and the information stored in the Human Fertilization and Embryology Authority's Register of Information, although further work than we have been able to undertake here is necessary to ensure a better fit where cross-border treatment services or informal arrangements have been involved. The time for debate and reform is well overdue.

  18. Generation and evaluation of 3D digital casts of maxillary defects based on multisource data registration: A pilot clinical study.

    PubMed

    Ye, Hongqiang; Ma, Qijun; Hou, Yuezhong; Li, Man; Zhou, Yongsheng

    2017-12-01

    Digital techniques are not clinically applied for 1-piece maxillary prostheses containing an obturator and removable partial denture retained by the remaining teeth because of the difficulty in obtaining sufficiently accurate 3-dimensional (3D) images. The purpose of this pilot clinical study was to generate 3D digital casts of maxillary defects, including the defective region and the maxillary dentition, based on multisource data registration and to evaluate their effectiveness. Twelve participants with maxillary defects were selected. The maxillofacial region was scanned with spiral computer tomography (CT), and the maxillary arch and palate were scanned using an intraoral optical scanner. The 3D images from the CT and intraoral scanner were registered and merged to form a 3D digital cast of the maxillary defect containing the anatomic structures needed for the maxillary prosthesis. This included the defect cavity, maxillary dentition, and palate. Traditional silicone impressions were also made, and stone casts were poured. The accuracy of the digital cast in comparison with that of the stone cast was evaluated by measuring the distance between 4 anatomic landmarks. Differences and consistencies were assessed using paired Student t tests and the intraclass correlation coefficient (ICC). In 3 participants, physical resin casts were produced by rapid prototyping from digital casts. Based on the resin casts, maxillary prostheses were fabricated by using conventional methods and then evaluated in the participants to assess the clinical applicability of the digital casts. Digital casts of the maxillary defects were generated and contained all the anatomic details needed for the maxillary prosthesis. Comparing the digital and stone casts, a paired Student t test indicated that differences in the linear distances between landmarks were not statistically significant (P>.05). High ICC values (0.977 to 0.998) for the interlandmark distances further indicated the high degree of consistency between the digital and stone casts. The maxillary prostheses showed good clinical effectiveness, indicating that the corresponding digital casts met the requirements for clinical application. Based on multisource data from spiral CT and the intraoral scanner, 3D digital casts of maxillary defects were generated using the registration technique. These casts were consistent with conventional stone casts in terms of accuracy and were suitable for clinical use. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.

  19. Towards local estimation of emphysema progression using image registration

    NASA Astrophysics Data System (ADS)

    Staring, M.; Bakker, M. E.; Shamonin, D. P.; Stolk, J.; Reiber, J. H. C.; Stoel, B. C.

    2009-02-01

    Progression measurement of emphysema is required to evaluate the health condition of a patient and the effect of drugs. To locally estimate progression we use image registration, which allows for volume correction using the determinant of the Jacobian of the transformation. We introduce an adaptation of the so-called sponge model that circumvents its constant-mass assumption. Preliminary results from CT scans of a lung phantom and from CT data sets of three patients suggest that image registration may be a suitable method to locally estimate emphysema progression.

  20. An Application of Rotation- and Translation-Invariant Overcomplete Wavelets to the registration of Remotely Sensed Imagery

    NASA Technical Reports Server (NTRS)

    LeMoigne, Jacqueline; Zavorine, Ilya

    1999-01-01

    A wavelet-based image registration approach has previously been proposed by the authors. In this work, wavelet coefficient maxima obtained from an orthogonal wavelet decomposition using Daubechies filters were utilized to register images in a multi-resolution fashion. Tested on several remote sensing datasets, this method gave very encouraging results. Despite the lack of translation-invariance of these filters, we showed that when using cross-correlation as a feature matching technique, features of size larger than twice the size of the filters are correctly registered by using the low-frequency subbands of the Daubechies wavelet decomposition. Nevertheless, high-frequency subbands are still sensitive to translation effects. In this work, we are considering a rotation- and translation-invariant representation developed by E. Simoncelli and integrate it in our image registration scheme. The two types of filters, Daubechies and Simoncelli filters, are then being compared from a registration point of view, utilizing synthetic data as well as data from the Landsat/ Thematic Mapper (TM) and from the NOAA Advanced Very High Resolution Radiometer (AVHRR).

  1. An Application of Rotation- and Translation-Invariant Overcomplete Wavelets to the Registration of Remotely Sensed Imagery

    NASA Technical Reports Server (NTRS)

    LeMoigne, Jacqueline; Zavorine, Ilya

    1999-01-01

    A wavelet-based image registration approach has previously been proposed by the authors. In this work, wavelet coefficient maxima obtained from an orthogonal wavelet decomposition using Daubechies filters were utilized to register images in a multi-resolution fashion. Tested on several remote sensing datasets, this method gave very encouraging results. Despite the lack of translation-invariance of these filters, we showed that when using cross-correlation as a feature matching technique, features of size larger than twice the size of the filters are correctly registered by using the low-frequency subbands of the Daubechies wavelet decomposition. Nevertheless, high-frequency subbands are still sensitive to translation effects. In this work, we are considering a rotation- and translation-invariant representation developed by E. Simoncelli and integrate it in our image registration scheme. The two types of filters, Daubechies and Simoncelli filters, are then being compared from a registration point of view, utilizing synthetic data as well as data from the Landsat/ Thematic Mapper (TM) and from the NOAA Advanced Very High Resolution Radiometer (AVHRR).

  2. Conventional 3D staging PET/CT in CT simulation for lung cancer: impact of rigid and deformable target volume alignments for radiotherapy treatment planning.

    PubMed

    Hanna, G G; Van Sörnsen De Koste, J R; Carson, K J; O'Sullivan, J M; Hounsell, A R; Senan, S

    2011-10-01

    Positron emission tomography (PET)/CT scans can improve target definition in radiotherapy for non-small cell lung cancer (NSCLC). As staging PET/CT scans are increasingly available, we evaluated different methods for co-registration of staging PET/CT data to radiotherapy simulation (RTP) scans. 10 patients underwent staging PET/CT followed by RTP PET/CT. On both scans, gross tumour volumes (GTVs) were delineated using CT (GTV(CT)) and PET display settings. Four PET-based contours (manual delineation, two threshold methods and a source-to-background ratio method) were delineated. The CT component of the staging scan was co-registered using both rigid and deformable techniques to the CT component of RTP PET/CT. Subsequently rigid registration and deformation warps were used to transfer PET and CT contours from the staging scan to the RTP scan. Dice's similarity coefficient (DSC) was used to assess the registration accuracy of staging-based GTVs following both registration methods with the GTVs delineated on the RTP PET/CT scan. When the GTV(CT) delineated on the staging scan after both rigid registration and deformation was compared with the GTV(CT)on the RTP scan, a significant improvement in overlap (registration) using deformation was observed (mean DSC 0.66 for rigid registration and 0.82 for deformable registration, p = 0.008). A similar comparison for PET contours revealed no significant improvement in overlap with the use of deformable registration. No consistent improvements in similarity measures were observed when deformable registration was used for transferring PET-based contours from a staging PET/CT. This suggests that currently the use of rigid registration remains the most appropriate method for RTP in NSCLC.

  3. Determination of optimal ultrasound planes for the initialisation of image registration during endoscopic ultrasound-guided procedures.

    PubMed

    Bonmati, Ester; Hu, Yipeng; Gibson, Eli; Uribarri, Laura; Keane, Geri; Gurusami, Kurinchi; Davidson, Brian; Pereira, Stephen P; Clarkson, Matthew J; Barratt, Dean C

    2018-06-01

    Navigation of endoscopic ultrasound (EUS)-guided procedures of the upper gastrointestinal (GI) system can be technically challenging due to the small fields-of-view of ultrasound and optical devices, as well as the anatomical variability and limited number of orienting landmarks during navigation. Co-registration of an EUS device and a pre-procedure 3D image can enhance the ability to navigate. However, the fidelity of this contextual information depends on the accuracy of registration. The purpose of this study was to develop and test the feasibility of a simulation-based planning method for pre-selecting patient-specific EUS-visible anatomical landmark locations to maximise the accuracy and robustness of a feature-based multimodality registration method. A registration approach was adopted in which landmarks are registered to anatomical structures segmented from the pre-procedure volume. The predicted target registration errors (TREs) of EUS-CT registration were estimated using simulated visible anatomical landmarks and a Monte Carlo simulation of landmark localisation error. The optimal planes were selected based on the 90th percentile of TREs, which provide a robust and more accurate EUS-CT registration initialisation. The method was evaluated by comparing the accuracy and robustness of registrations initialised using optimised planes versus non-optimised planes using manually segmented CT images and simulated ([Formula: see text]) or retrospective clinical ([Formula: see text]) EUS landmarks. The results show a lower 90th percentile TRE when registration is initialised using the optimised planes compared with a non-optimised initialisation approach (p value [Formula: see text]). The proposed simulation-based method to find optimised EUS planes and landmarks for EUS-guided procedures may have the potential to improve registration accuracy. Further work will investigate applying the technique in a clinical setting.

  4. TU-AB-202-06: Quantitative Evaluation of Deformable Image Registration in MRI-Guided Adaptive Radiation Therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mooney, K; Zhao, T; Green, O

    Purpose: To assess the performance of the deformable image registration algorithm used for MRI-guided adaptive radiation therapy using image feature analysis. Methods: MR images were collected from five patients treated on the MRIdian (ViewRay, Inc., Oakwood Village, OH), a three head Cobalt-60 therapy machine with an 0.35 T MR system. The images were acquired immediately prior to treatment with a uniform 1.5 mm resolution. Treatment sites were as follows: head/neck, lung, breast, stomach, and bladder. Deformable image registration was performed using the ViewRay software between the first fraction MRI and the final fraction MRI, and the DICE similarity coefficient (DSC)more » for the skin contours was reported. The SIFT and Harris feature detection and matching algorithms identified point features in each image separately, then found matching features in the other image. The target registration error (TRE) was defined as the vector distance between matched features on the two image sets. Each deformation was evaluated based on comparison of average TRE and DSC. Results: Image feature analysis produced between 2000–9500 points for evaluation on the patient images. The average (± standard deviation) TRE for all patients was 3.3 mm (±3.1 mm), and the passing rate of TRE<3 mm was 60% on the images. The head/neck patient had the best average TRE (1.9 mm±2.3 mm) and the best passing rate (80%). The lung patient had the worst average TRE (4.8 mm±3.3 mm) and the worst passing rate (37.2%). DSC was not significantly correlated with either TRE (p=0.63) or passing rate (p=0.55). Conclusions: Feature matching provides a quantitative assessment of deformable image registration, with a large number of data points for analysis. The TRE of matched features can be used to evaluate the registration of many objects throughout the volume, whereas DSC mainly provides a measure of gross overlap. We have a research agreement with ViewRay Inc.« less

  5. Optometrists Association Australia Universal (entry-level) and Therapeutic Competency Standards for Optometry 2008.

    PubMed

    Kiely, Patricia M

    2009-07-01

    Competency standards for entry-level to the profession of optometry in Australia were first developed in 1993, revised in 1997 and expanded in 2000 to include therapeutic competency standards. The entry-level standards cover the competencies required by a person entering the profession without therapeutic endorsement of their registration. The therapeutic competency standards address the additional competencies required for therapeutic endorsement of registration. This paper presents a revised version of the universal (entry-level) and therapeutic competency standards for the profession of optometry in Australia in 2008. Expert members of the profession and representatives from schools of optometry, registration boards in Australia, state divisions of Optometrists Association Australia and the New Zealand Association of Optometrists were consulted in the process of updating the standards. Three new elements of competency have been added to the standards. Twenty-three new performance criteria with associated indicators have been added. Some performance criteria from the earlier document have been combined. Substantial alterations were made to the presentation of indicators throughout the document. The updated entry-level (universal) and therapeutic competency standards were adopted on behalf of the profession by the National Council of Optometrists Association Australia in November 2008. Competency standards are used by Australian and New Zealand registration authorities for the purposes of registration and therapeutic endorsement of registration via the Optometry Council of Australia and New Zealand accreditation and assessment processes. They have also been used as the basis of the World Council of Optometry Global Competency-Based Model.

  6. Toward adaptive radiotherapy for head and neck patients: Uncertainties in dose warping due to the choice of deformable registration algorithm

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Veiga, Catarina, E-mail: catarina.veiga.11@ucl.ac.uk; Royle, Gary; Lourenço, Ana Mónica

    2015-02-15

    Purpose: The aims of this work were to evaluate the performance of several deformable image registration (DIR) algorithms implemented in our in-house software (NiftyReg) and the uncertainties inherent to using different algorithms for dose warping. Methods: The authors describe a DIR based adaptive radiotherapy workflow, using CT and cone-beam CT (CBCT) imaging. The transformations that mapped the anatomy between the two time points were obtained using four different DIR approaches available in NiftyReg. These included a standard unidirectional algorithm and more sophisticated bidirectional ones that encourage or ensure inverse consistency. The forward (CT-to-CBCT) deformation vector fields (DVFs) were used tomore » propagate the CT Hounsfield units and structures to the daily geometry for “dose of the day” calculations, while the backward (CBCT-to-CT) DVFs were used to remap the dose of the day onto the planning CT (pCT). Data from five head and neck patients were used to evaluate the performance of each implementation based on geometrical matching, physical properties of the DVFs, and similarity between warped dose distributions. Geometrical matching was verified in terms of dice similarity coefficient (DSC), distance transform, false positives, and false negatives. The physical properties of the DVFs were assessed calculating the harmonic energy, determinant of the Jacobian, and inverse consistency error of the transformations. Dose distributions were displayed on the pCT dose space and compared using dose difference (DD), distance to dose difference, and dose volume histograms. Results: All the DIR algorithms gave similar results in terms of geometrical matching, with an average DSC of 0.85 ± 0.08, but the underlying properties of the DVFs varied in terms of smoothness and inverse consistency. When comparing the doses warped by different algorithms, we found a root mean square DD of 1.9% ± 0.8% of the prescribed dose (pD) and that an average of 9% ± 4% of voxels within the treated volume failed a 2%pD DD-test (DD{sub 2%-pp}). Larger DD{sub 2%-pp} was found within the high dose gradient (21% ± 6%) and regions where the CBCT quality was poorer (28% ± 9%). The differences when estimating the mean and maximum dose delivered to organs-at-risk were up to 2.0%pD and 2.8%pD, respectively. Conclusions: The authors evaluated several DIR algorithms for CT-to-CBCT registrations. In spite of all methods resulting in comparable geometrical matching, the choice of DIR implementation leads to uncertainties in dose warped, particularly in regions of high gradient and/or poor imaging quality.« less

  7. 75 FR 34111 - Notice of Intent to Suspend Certain Pesticide Registrations

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-06-16

    ... a person adversely affected by the Notice of Intent to Suspend or the registrant has satisfied the... Notice of Intent to Suspend). FOR FURTHER INFORMATION CONTACT: Terria Northern, Pesticide Re- evaluation..., consult the person listed under FOR FURTHER INFORMATION CONTACT. B. How Can I Get Copies of this Document...

  8. 21 CFR 607.25 - Information required for establishment registration and blood product listing.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 7 2011-04-01 2010-04-01 true Information required for establishment registration and blood product listing. 607.25 Section 607.25 Food and Drugs FOOD AND DRUG ADMINISTRATION... the manufacturer issued by the Center for Biologics Evaluation and Research, Food and Drug...

  9. 21 CFR 607.25 - Information required for establishment registration and blood product listing.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 7 2010-04-01 2010-04-01 false Information required for establishment registration and blood product listing. 607.25 Section 607.25 Food and Drugs FOOD AND DRUG ADMINISTRATION... the manufacturer issued by the Center for Biologics Evaluation and Research, Food and Drug...

  10. 75 FR 53976 - Risks and Benefits of Long-Term Use of Nicotine Replacement Therapy Products; Public Workshop...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-09-02

    ...-0002, 301-796-3519, email: [email protected] ; or Dominic Chiapperino, Center for Drug Evaluation... Spring, MD 20993-0002, 301- 796-1183, email: [email protected] . Registration to Attend the... public hearing, please email your registration to [email protected] by October 5, 2010. Those...

  11. Pesticide authorization in the EU-environment unprotected?

    PubMed

    Stehle, Sebastian; Schulz, Ralf

    2015-12-01

    Pesticides constitute an integral part of high-intensity European agriculture. Prior to their authorization, a highly elaborated environmental risk assessment is mandatory according to EU pesticide legislation, i.e., Regulation (EC) No. 1107/2009. However, no field data-based evaluation of the risk assessment outcome, i.e., the regulatory acceptable concentrations (RACs), and therefore of the overall protectiveness of EU pesticide regulations exists. We conducted here a comprehensive meta-analysis using peer-reviewed literature on agricultural insecticide concentrations in EU surface waters and evaluated associated risks using the RACs derived from official European pesticide registration documents. As a result, 44.7 % of the 1566 cases of measured insecticide concentrations (MICs) in EU surface waters exceeded their respective RACs. It follows that current EU pesticide regulations do not protect the aquatic environment and that insecticides threaten aquatic biodiversity. RAC exceedances were significantly higher for insecticides authorized using conservative tier-I RACs and for more recently developed insecticide classes, i.e., pyrethroids. In addition, we identified higher risks, e.g., for smaller surface waters that are specifically considered in the regulatory risk assessment schemes. We illustrate the shortcomings of the EU regulatory risk assessment using two case studies that contextualize the respective risk assessment outcomes to field exposure. Overall, our meta-analysis challenges the field relevance and protectiveness of the regulatory environmental risk assessment conducted for pesticide authorization in the EU and indicates that critical revisions of related pesticide regulations and effective mitigation measures are urgently needed to substantially reduce the environmental risks arising from agricultural insecticide use.

  12. Registration of 4D cardiac CT sequences under trajectory constraints with multichannel diffeomorphic demons.

    PubMed

    Peyrat, Jean-Marc; Delingette, Hervé; Sermesant, Maxime; Xu, Chenyang; Ayache, Nicholas

    2010-07-01

    We propose a framework for the nonlinear spatiotemporal registration of 4D time-series of images based on the Diffeomorphic Demons (DD) algorithm. In this framework, the 4D spatiotemporal registration is decoupled into a 4D temporal registration, defined as mapping physiological states, and a 4D spatial registration, defined as mapping trajectories of physical points. Our contribution focuses more specifically on the 4D spatial registration that should be consistent over time as opposed to 3D registration that solely aims at mapping homologous points at a given time-point. First, we estimate in each sequence the motion displacement field, which is a dense representation of the point trajectories we want to register. Then, we perform simultaneously 3D registrations of corresponding time-points with the constraints to map the same physical points over time called the trajectory constraints. Under these constraints, we show that the 4D spatial registration can be formulated as a multichannel registration of 3D images. To solve it, we propose a novel version of the Diffeomorphic Demons (DD) algorithm extended to vector-valued 3D images, the Multichannel Diffeomorphic Demons (MDD). For evaluation, this framework is applied to the registration of 4D cardiac computed tomography (CT) sequences and compared to other standard methods with real patient data and synthetic data simulated from a physiologically realistic electromechanical cardiac model. Results show that the trajectory constraints act as a temporal regularization consistent with motion whereas the multichannel registration acts as a spatial regularization. Finally, using these trajectory constraints with multichannel registration yields the best compromise between registration accuracy, temporal and spatial smoothness, and computation times. A prospective example of application is also presented with the spatiotemporal registration of 4D cardiac CT sequences of the same patient before and after radiofrequency ablation (RFA) in case of atrial fibrillation (AF). The intersequence spatial transformations over a cardiac cycle allow to analyze and quantify the regression of left ventricular hypertrophy and its impact on the cardiac function.

  13. Multi-template tensor-based morphometry: Application to analysis of Alzheimer's disease

    PubMed Central

    Koikkalainen, Juha; Lötjönen, Jyrki; Thurfjell, Lennart; Rueckert, Daniel; Waldemar, Gunhild; Soininen, Hilkka

    2012-01-01

    In this paper methods for using multiple templates in tensor-based morphometry (TBM) are presented and comparedtothe conventional single-template approach. TBM analysis requires non-rigid registrations which are often subject to registration errors. When using multiple templates and, therefore, multiple registrations, it can be assumed that the registration errors are averaged and eventually compensated. Four different methods are proposed for multi-template TBM. The methods were evaluated using magnetic resonance (MR) images of healthy controls, patients with stable or progressive mild cognitive impairment (MCI), and patients with Alzheimer's disease (AD) from the ADNI database (N=772). The performance of TBM features in classifying images was evaluated both quantitatively and qualitatively. Classification results show that the multi-template methods are statistically significantly better than the single-template method. The overall classification accuracy was 86.0% for the classification of control and AD subjects, and 72.1%for the classification of stable and progressive MCI subjects. The statistical group-level difference maps produced using multi-template TBM were smoother, formed larger continuous regions, and had larger t-values than the maps obtained with single-template TBM. PMID:21419228

  14. Evaluation of registration accuracy between Sentinel-2 and Landsat 8

    NASA Astrophysics Data System (ADS)

    Barazzetti, Luigi; Cuca, Branka; Previtali, Mattia

    2016-08-01

    Starting from June 2015, Sentinel-2A is delivering high resolution optical images (ground resolution up to 10 meters) to provide a global coverage of the Earth's land surface every 10 days. The planned launch of Sentinel-2B along with the integration of Landsat images will provide time series with an unprecedented revisit time indispensable for numerous monitoring applications, in which high resolution multi-temporal information is required. They include agriculture, water bodies, natural hazards to name a few. However, the combined use of multi-temporal images requires an accurate geometric registration, i.e. pixel-to-pixel correspondence for terrain-corrected products. This paper presents an analysis of spatial co-registration accuracy for several datasets of Sentinel-2 and Landsat 8 images distributed all around the world. Images were compared with digital correlation techniques for image matching, obtaining an evaluation of registration accuracy with an affine transformation as geometrical model. Results demonstrate that sub-pixel accuracy was achieved between 10 m resolution Sentinel-2 bands (band 3) and 15 m resolution panchromatic Landsat images (band 8).

  15. A gaussian mixture + demons deformable registration method for cone-beam CT-guided robotic transoral base-of-tongue surgery

    NASA Astrophysics Data System (ADS)

    Reaungamornrat, S.; Liu, W. P.; Schafer, S.; Otake, Y.; Nithiananthan, S.; Uneri, A.; Richmon, J.; Sorger, J.; Siewerdsen, J. H.; Taylor, R. H.

    2013-03-01

    Purpose: An increasingly popular minimally invasive approach to resection of oropharyngeal / base-of-tongue cancer is made possible by a transoral technique conducted with the assistance of a surgical robot. However, the highly deformed surgical setup (neck flexed, mouth open, and tongue retracted) compared to the typical patient orientation in preoperative images poses a challenge to guidance and localization of the tumor target and adjacent critical anatomy. Intraoperative cone-beam CT (CBCT) can account for such deformation, but due to the low contrast of soft-tissue in CBCT images, direct localization of the target and critical tissues in CBCT images can be difficult. Such structures may be more readily delineated in preoperative CT or MR images, so a method to deformably register such information to intraoperative CBCT could offer significant value. This paper details the initial implementation of a deformable registration framework to align preoperative images with the deformed intraoperative scene and gives preliminary evaluation of the geometric accuracy of registration in CBCT-guided TORS. Method: The deformable registration aligns preoperative CT or MR to intraoperative CBCT by integrating two established approaches. The volume of interest is first segmented (specifically, the region of the tongue from the tip to the hyoid), and a Gaussian mixture (GM) mode1 of surface point clouds is used for rigid initialization (GMRigid) as well as an initial deformation (GMNonRigid). Next, refinement of the registration is performed using the Demons algorithm applied to distance transformations of the GM-registered and CBCT volumes. The registration accuracy of the framework was quantified in preliminary studies using a cadaver emulating preoperative and intraoperative setups. Geometric accuracy of registration was quantified in terms of target registration error (TRE) and surface distance error. Result: With each step of the registration process, the framework demonstrated improved registration, achieving mean TRE of 3.0 mm following the GM rigid, 1.9 mm following GM nonrigid, and 1.5 mm at the output of the registration process. Analysis of surface distance demonstrated a corresponding improvement of 2.2, 0.4, and 0.3 mm, respectively. The evaluation of registration error revealed the accurate alignment in the region of interest for base-of-tongue robotic surgery owing to point-set selection in the GM steps and refinement in the deep aspect of the tongue in the Demons step. Conclusions: A promising framework has been developed for CBCT-guided TORS in which intraoperative CBCT provides a basis for registration of preoperative images to the highly deformed intraoperative setup. The registration framework is invariant to imaging modality (accommodating preoperative CT or MR) and is robust against CBCT intensity variations and artifact, provided corresponding segmentation of the volume of interest. The approach could facilitate overlay of preoperative planning data directly in stereo-endoscopic video in support of CBCT-guided TORS.

  16. Deformable and rigid registration of MRI and microPET images for photodynamic therapy of cancer in mice

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fei Baowei; Wang Hesheng; Muzic, Raymond F. Jr.

    2006-03-15

    We are investigating imaging techniques to study the tumor response to photodynamic therapy (PDT). Positron emission tomography (PET) can provide physiological and functional information. High-resolution magnetic resonance imaging (MRI) can provide anatomical and morphological changes. Image registration can combine MRI and PET images for improved tumor monitoring. In this study, we acquired high-resolution MRI and microPET {sup 18}F-fluorodeoxyglucose (FDG) images from C3H mice with RIF-1 tumors that were treated with Pc 4-based PDT. We developed two registration methods for this application. For registration of the whole mouse body, we used an automatic three-dimensional, normalized mutual information algorithm. For tumor registration,more » we developed a finite element model (FEM)-based deformable registration scheme. To assess the quality of whole body registration, we performed slice-by-slice review of both image volumes; manually segmented feature organs, such as the left and right kidneys and the bladder, in each slice; and computed the distance between corresponding centroids. Over 40 volume registration experiments were performed with MRI and microPET images. The distance between corresponding centroids of organs was 1.5{+-}0.4 mm which is about 2 pixels of microPET images. The mean volume overlap ratios for tumors were 94.7% and 86.3% for the deformable and rigid registration methods, respectively. Registration of high-resolution MRI and microPET images combines anatomical and functional information of the tumors and provides a useful tool for evaluating photodynamic therapy.« less

  17. Nonrigid registration of carotid ultrasound and MR images using a "twisting and bending" model

    NASA Astrophysics Data System (ADS)

    Nanayakkara, Nuwan D.; Chiu, Bernard; Samani, Abbas; Spence, J. David; Parraga, Grace; Samarabandu, Jagath; Fenster, Aaron

    2008-03-01

    Atherosclerosis at the carotid bifurcation resulting in cerebral emboli is a major cause of ischemic stroke. Most strokes associated with carotid atherosclerosis can be prevented by lifestyle/dietary changes and pharmacological treatments if identified early by monitoring carotid plaque changes. Plaque composition information from magnetic resonance (MR) carotid images and dynamic characteristics information from 3D ultrasound (US) are necessary for developing and validating US imaging tools to identify vulnerable carotid plaques. Combining these images requires nonrigid registration to correct the non-linear miss-alignments caused by relative twisting and bending in the neck due to different head positions during the two image acquisitions sessions. The high degree of freedom and large number of parameters associated with existing nonrigid image registration methods causes several problems including unnatural plaque morphology alteration, computational complexity, and low reliability. Our approach was to model the normal movement of the neck using a "twisting and bending model" with only six parameters for nonrigid registration. We evaluated our registration technique using intra-subject in-vivo 3D US and 3D MR carotid images acquired on the same day. We calculated the Mean Registration Error (MRE) between the segmented vessel surfaces in the target image and the registered image using a distance-based error metric after applying our "twisting bending model" based nonrigid registration algorithm. We achieved an average registration error of 1.33+/-0.41mm using our nonrigid registration technique. Visual inspection of segmented vessel surfaces also showed a substantial improvement of alignment with our non-rigid registration technique.

  18. Validation of a deformable image registration technique for cone beam CT-based dose verification

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Moteabbed, M., E-mail: mmoteabbed@partners.org; Sharp, G. C.; Wang, Y.

    2015-01-15

    Purpose: As radiation therapy evolves toward more adaptive techniques, image guidance plays an increasingly important role, not only in patient setup but also in monitoring the delivered dose and adapting the treatment to patient changes. This study aimed to validate a method for evaluation of delivered intensity modulated radiotherapy (IMRT) dose based on multimodal deformable image registration (DIR) for prostate treatments. Methods: A pelvic phantom was scanned with CT and cone-beam computed tomography (CBCT). Both images were digitally deformed using two realistic patient-based deformation fields. The original CT was then registered to the deformed CBCT resulting in a secondary deformedmore » CT. The registration quality was assessed as the ability of the DIR method to recover the artificially induced deformations. The primary and secondary deformed CT images as well as vector fields were compared to evaluate the efficacy of the registration method and it’s suitability to be used for dose calculation. PLASTIMATCH, a free and open source software was used for deformable image registration. A B-spline algorithm with optimized parameters was used to achieve the best registration quality. Geometric image evaluation was performed through voxel-based Hounsfield unit (HU) and vector field comparison. For dosimetric evaluation, IMRT treatment plans were created and optimized on the original CT image and recomputed on the two warped images to be compared. The dose volume histograms were compared for the warped structures that were identical in both warped images. This procedure was repeated for the phantom with full, half full, and empty bladder. Results: The results indicated mean HU differences of up to 120 between registered and ground-truth deformed CT images. However, when the CBCT intensities were calibrated using a region of interest (ROI)-based calibration curve, these differences were reduced by up to 60%. Similarly, the mean differences in average vector field lengths decreased from 10.1 to 2.5 mm when CBCT was calibrated prior to registration. The results showed no dependence on the level of bladder filling. In comparison with the dose calculated on the primary deformed CT, differences in mean dose averaged over all organs were 0.2% and 3.9% for dose calculated on the secondary deformed CT with and without CBCT calibration, respectively, and 0.5% for dose calculated directly on the calibrated CBCT, for the full-bladder scenario. Gamma analysis for the distance to agreement of 2 mm and 2% of prescribed dose indicated a pass rate of 100% for both cases involving calibrated CBCT and on average 86% without CBCT calibration. Conclusions: Using deformable registration on the planning CT images to evaluate the IMRT dose based on daily CBCTs was found feasible. The proposed method will provide an accurate dose distribution using planning CT and pretreatment CBCT data, avoiding the additional uncertainties introduced by CBCT inhomogeneity and artifacts. This is a necessary initial step toward future image-guided adaptive radiotherapy of the prostate.« less

  19. Registration uncertainties between 3D cone beam computed tomography and different reference CT datasets in lung stereotactic body radiation therapy.

    PubMed

    Oechsner, Markus; Chizzali, Barbara; Devecka, Michal; Combs, Stephanie Elisabeth; Wilkens, Jan Jakob; Duma, Marciana Nona

    2016-10-26

    The aim of this study was to analyze differences in couch shifts (setup errors) resulting from image registration of different CT datasets with free breathing cone beam CTs (FB-CBCT). As well automatic as manual image registrations were performed and registration results were correlated to tumor characteristics. FB-CBCT image registration was performed for 49 patients with lung lesions using slow planning CT (PCT), average intensity projection (AIP), maximum intensity projection (MIP) and mid-ventilation CTs (MidV) as reference images. Both, automatic and manual image registrations were applied. Shift differences were evaluated between the registered CT datasets for automatic and manual registration, respectively. Furthermore, differences between automatic and manual registration were analyzed for the same CT datasets. The registration results were statistically analyzed and correlated to tumor characteristics (3D tumor motion, tumor volume, superior-inferior (SI) distance, tumor environment). Median 3D shift differences over all patients were between 0.5 mm (AIPvsMIP) and 1.9 mm (MIPvsPCT and MidVvsPCT) for the automatic registration and between 1.8 mm (AIPvsPCT) and 2.8 mm (MIPvsPCT and MidVvsPCT) for the manual registration. For some patients, large shift differences (>5.0 mm) were found (maximum 10.5 mm, automatic registration). Comparing automatic vs manual registrations for the same reference CTs, ∆AIP achieved the smallest (1.1 mm) and ∆MIP the largest (1.9 mm) median 3D shift differences. The standard deviation (variability) for the 3D shift differences was also the smallest for ∆AIP (1.1 mm). Significant correlations (p < 0.01) between 3D shift difference and 3D tumor motion (AIPvsMIP, MIPvsMidV) and SI distance (AIPvsMIP) (automatic) and also for 3D tumor motion (∆PCT, ∆MidV; automatic vs manual) were found. Using different CT datasets for image registration with FB-CBCTs can result in different 3D couch shifts. Manual registrations achieved partly different 3D shifts than automatic registrations. AIP CTs yielded the smallest shift differences and might be the most appropriate CT dataset for registration with 3D FB-CBCTs.

  20. Using reusable learning objects (rlos) in injection skills teaching: Evaluations from multiple user types.

    PubMed

    Williams, Julia; O'Connor, Mórna; Windle, Richard; Wharrad, Heather J

    2015-12-01

    Clinical skills are a critical component of pre-registration nurse education in the United Kingdom, yet there is widespread concern about the clinical skills displayed by newly-qualified nurses. Novel means of supporting clinical skills education are required to address this. A package of Reusable Learning Objects (RLOs) was developed to supplement pre-registration teaching on the clinical skill of administering injection medication. RLOs are electronic resources addressing a single learning objective whose interactivity facilitates learning. This article evaluates a package of five injection RLOs across three studies: (1) questionnaires administered to pre-registration nursing students at University of Nottingham (UoN) (n=46) evaluating the RLO package as a whole; (2) individual RLOs evaluated in online questionnaires by educators and students from UoN; from other national and international institutions; and healthcare professionals (n=265); (3) qualitative evaluation of the RLO package by UoN injection skills tutors (n=6). Data from all studies were assessed for (1) access to, (2) usefulness, (3) impact and (4) integration of the RLOs. Study one found that pre-registration nursing students rate the RLO package highly across all categories, particularly underscoring the value of their self-test elements. Study two found high ratings in online assessments of individual RLOs by multiple users. The global reach is particularly encouraging here. Tutors reported insufficient levels of student-RLO access, which might be explained by the timing of their student exposure. Tutors integrate RLOs into teaching and agree on their use as teaching supplements, not substitutes for face-to-face education. This evaluation encompasses the first years postpackage release. Encouraging data on evaluative categories in this early review suggest that future evaluations are warranted to track progress as the package is adopted and evaluated more widely. Copyright © 2015 Elsevier Ltd. All rights reserved.

  1. Custom Career Expos.

    ERIC Educational Resources Information Center

    Barnard, Tracie

    2001-01-01

    At Florida State University, the career placement staff tailors its career expos to the needs of students and employers. This article discusses how they market their expos; their online recruiter registration; how they recruit volunteers; and the importance of hospitality. (Author/MKA)

  2. Fast interactive elastic registration of 12-bit multi-spectral images with subvoxel accuracy using display hardware

    NASA Astrophysics Data System (ADS)

    Noordmans, Herke Jan; de Roode, Rowland; Verdaasdonk, Rudolf

    2007-03-01

    Multi-spectral images of human tissue taken in-vivo often contain image alignment problems as patients have difficulty in retaining their posture during the acquisition time of 20 seconds. Previously, it has been attempted to correct motion errors with image registration software developed for MR or CT data but these algorithms have been proven to be too slow and erroneous for practical use with multi-spectral images. A new software package has been developed which allows the user to play a decisive role in the registration process as the user can monitor the progress of the registration continuously and force it in the right direction when it starts to fail. The software efficiently exploits videocard hardware to gain speed and to provide a perfect subvoxel correspondence between registration field and display. An 8 bit graphic card was used to efficiently register and resample 12 bit images using the hardware interpolation modes present on the graphic card. To show the feasibility of this new registration process, the software was applied in clinical practice evaluating the dosimetry for psoriasis and KTP laser treatment. The microscopic differences between images of normal skin and skin exposed to UV light proved that an affine registration step including zooming and slanting is critical for a subsequent elastic match to have success. The combination of user interactive registration software with optimal addressing the potentials of PC video card hardware greatly improves the speed of multi spectral image registration.

  3. Ultrasound guidance system for prostate biopsy

    NASA Astrophysics Data System (ADS)

    Hummel, Johann; Kerschner, Reinhard; Kaar, Marcus; Birkfellner, Wolfgang; Figl, Michael

    2017-03-01

    We designed a guidance system for prostate biopsy based on PET/MR images and 3D ultrasound (US). With our proposed method common inter-modal MR-US (or CT-US in case of PET/CTs) registration can be replaced by an intra-modal 3D/3D-US/US registration and an optical tracking system (OTS). On the pre-operative site, a PET/MR calibration allows to link both hybrid modalities with an abdominal 3D-US. On the interventional site, another abdominal 3D US is taken to merge the pre-operative images with the real-time 3D-US via 3D/3D-US/US registration. Finally, the images of a tracked trans-rectal US probe can be displayed with the pre-operative images by overlay. For PET/MR image fusion we applied a point-to-point registration between PET and OTS and MR and OTS, respectively. 3D/3D-US/US registration was evaluated for images taken in supine and lateral patient position. To enable table shifts between PET/MR and US image acquisition a table calibration procedure is presented. We found fiducial registration errors of 0.9 mm and 2.8 mm, respectively, with respect to the MR and PET calibration. A target registration error between MR and 3D US amounted to 1.4 mm. The registration error for the 3D/3D-US/US registration was found to be 3.7 mm. Furthermore, we have shown that ultrasound is applicable in an MR environment.

  4. Clinical trial transparency: many gains but access to evidence for new medicines remains imperfect.

    PubMed

    Mintzes, Barbara; Lexchin, Joel; Quintano, Ancella Santos

    2015-01-01

    Although selective and incomplete publication is widely acknowledged to be a problem, full access to clinical trial data remains illusive. Authors' personal files, key documents from Food and Drug Administration and European Medicines Agency and focussed searches of PubMed. Existing sources of information provide an incomplete overview of scientific research. Persistent arguments about commercial confidentiality and the potential difficulties in de-identifying raw data can block important progress. Current industry efforts are voluntary and only partially satisfy the need for complete data. Requirements for trial registration are increasing. Important regulatory changes in particular in Europe have the potential to result in the release of more information. Documenting the effects of prospective trial registration and requirements for proactive clinical trial publication on healthcare decisions, public health and rational resource allocation. © The Author 2015. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  5. [Problems of demographic data collecting in Arab countries of the Middle East].

    PubMed

    Chasteland, J C

    1970-06-01

    12 Middle Eastern Arab countries can be divided into 5 northern countries with demographic data from census or survey and 7 southern countries primarily in the Arabian peninsula (Bahrien excepted) with no data. Obstacles include lack of information on tribes, migrations, and even nomadic status, large areas with sparse population, low socioeconom ic and literacy levels, and cumbersome registration systems. The author computed the index of regularity of age and sex, age distribution by sex, and crude birth-, death, and infant mortality rates to estimate the validity of existing data in each country. These estimates showed that for birthrates registration was about 100% complete for Kuwait and Jordan, 80% for Libya, 60% for Syria, 40% for Iraq. For mortality the registration was so poor that it is only about 30%-40% complete, even in Kuwait and Libya. Data on infant mortality are also poor and have apparently worsened in the 1960s compared with the 1950s. Bias probably exists in birth place, marital status, education, and profession. The author suggested that in southern countries a census should proceed over several years in steps: 1) lists of towns and tribes, 2) simple head count, and 3) complete census. valid vital statistics are urgently needed for national economic planning.

  6. Infant mortality in the Marshall Islands.

    PubMed

    Levy, S J; Booth, H

    1988-12-01

    Levy and Booth present previously unpublished infant mortality rates for the Marshall Islands. They use an indirect method to estimate infant mortality from the 1973 and 1980 censuses, then apply indirect and direct methods of estimation to data from the Marshall Islands Women's Health Survey of 1985. Comparing the results with estimates of infant mortality obtained from vital registration data enables them to estimate the extent of underregistration of infant deaths. The authors conclude that 1973 census appears to be the most valid information source. Direct estimates from the Women's Health Survey data suggest that infant mortality has increased since 1970-1974, whereas the indirect estimates indicate a decreasing trend in infant mortality rates, converging with the direct estimates in more recent years. In view of increased efforts to improve maternal and child health in the mid-1970s, the decreasing trend is plausible. It is impossible to estimate accurately infant mortality in the Marshall Islands during 1980-1984 from the available data. Estimates based on registration data for 1975-1979 are at least 40% too low. The authors speculate that the estimate of 33 deaths per 1000 live births obtained from registration data for 1984 is 40-50% too low. In round figures, a value of 60 deaths per 1000 may be taken as the final estimate for 1980-1984.

  7. Optimization of PET-MR Registrations for Nonhuman Primates Using Mutual Information Measures: A Multi-Transform Method (MTM)

    PubMed Central

    Sandiego, Christine M.; Weinzimmer, David; Carson, Richard E.

    2012-01-01

    An important step in PET brain kinetic analysis is the registration of functional data to an anatomical MR image. Typically, PET-MR registrations in nonhuman primate neuroreceptor studies used PET images acquired early post-injection, (e.g., 0–10 min) to closely resemble the subject’s MR image. However, a substantial fraction of these registrations (~25%) fail due to the differences in kinetics and distribution for various radiotracer studies and conditions (e.g., blocking studies). The Multi-Transform Method (MTM) was developed to improve the success of registrations between PET and MR images. Two algorithms were evaluated, MTM-I and MTM-II. The approach involves creating multiple transformations by registering PET images of different time intervals, from a dynamic study, to a single reference (i.e., MR image) (MTM-I) or to multiple reference images (i.e., MR and PET images pre-registered to the MR) (MTM-II). Normalized mutual information was used to compute similarity between the transformed PET images and the reference image(s) to choose the optimal transformation. This final transformation is used to map the dynamic dataset into the animal’s anatomical MR space, required for kinetic analysis. The chosen transformed from MTM-I and MTM-II were evaluated using visual rating scores to assess the quality of spatial alignment between the resliced PET and reference. One hundred twenty PET datasets involving eleven different tracers from 3 different scanners were used to evaluate the MTM algorithms. Studies were performed with baboons and rhesus monkeys on the HR+, HRRT, and Focus-220. Successful transformations increased from 77.5%, 85.8%, to 96.7% using the 0–10 min method, MTM-I, and MTM-II, respectively, based on visual rating scores. The Multi-Transform Methods proved to be a robust technique for PET-MR registrations for a wide range of PET studies. PMID:22926293

  8. Slice-to-Volume Nonrigid Registration of Histological Sections to MR Images of the Human Brain

    PubMed Central

    Osechinskiy, Sergey; Kruggel, Frithjof

    2011-01-01

    Registration of histological images to three-dimensional imaging modalities is an important step in quantitative analysis of brain structure, in architectonic mapping of the brain, and in investigation of the pathology of a brain disease. Reconstruction of histology volume from serial sections is a well-established procedure, but it does not address registration of individual slices from sparse sections, which is the aim of the slice-to-volume approach. This study presents a flexible framework for intensity-based slice-to-volume nonrigid registration algorithms with a geometric transformation deformation field parametrized by various classes of spline functions: thin-plate splines (TPS), Gaussian elastic body splines (GEBS), or cubic B-splines. Algorithms are applied to cross-modality registration of histological and magnetic resonance images of the human brain. Registration performance is evaluated across a range of optimization algorithms and intensity-based cost functions. For a particular case of histological data, best results are obtained with a TPS three-dimensional (3D) warp, a new unconstrained optimization algorithm (NEWUOA), and a correlation-coefficient-based cost function. PMID:22567290

  9. Efficient Multi-Atlas Registration using an Intermediate Template Image

    PubMed Central

    Dewey, Blake E.; Carass, Aaron; Blitz, Ari M.; Prince, Jerry L.

    2017-01-01

    Multi-atlas label fusion is an accurate but time-consuming method of labeling the human brain. Using an intermediate image as a registration target can allow researchers to reduce time constraints by storing the deformations required of the atlas images. In this paper, we investigate the effect of registration through an intermediate template image on multi-atlas label fusion and propose a novel registration technique to counteract the negative effects of through-template registration. We show that overall computation time can be decreased dramatically with minimal impact on final label accuracy and time can be exchanged for improved results in a predictable manner. We see almost complete recovery of Dice similarity over a simple through-template registration using the corrected method and still maintain a 3–4 times speed increase. Further, we evaluate the effectiveness of this method on brains of patients with normal-pressure hydrocephalus, where abnormal brain shape presents labeling difficulties, specifically the ventricular labels. Our correction method creates substantially better ventricular labeling than traditional methods and maintains the speed increase seen in healthy subjects. PMID:28943702

  10. MRI and CBCT image registration of temporomandibular joint: a systematic review.

    PubMed

    Al-Saleh, Mohammed A Q; Alsufyani, Noura A; Saltaji, Humam; Jaremko, Jacob L; Major, Paul W

    2016-05-10

    The purpose of the present review is to systematically and critically analyze the available literature regarding the importance, applicability, and practicality of (MRI), computerized tomography (CT) or cone-beam CT (CBCT) image registration for TMJ anatomy and assessment. A systematic search of 4 databases; MEDLINE, EMBASE, EBM reviews and Scopus, was conducted by 2 reviewers. An additional manual search of the bibliography was performed. All articles discussing the magnetic resonance imaging MRI and CT or CBCT image registration for temporomandibular joint (TMJ) visualization or assessment were included. Only 3 articles satisfied the inclusion criteria. All included articles were published within the last 7 years. Two articles described MRI to CT multimodality image registration as a complementary tool to visualize TMJ. Both articles used images of one patient only to introduce the complementary concept of MRI-CT fused image. One article assessed the reliability of using MRI-CBCT registration to evaluate the TMJ disc position and osseous pathology for 10 temporomandibular disorder (TMD) patients. There are very limited studies of MRI-CT/CBCT registration to reach a conclusion regarding its accuracy or clinical use in the temporomandibular joints.

  11. Efficient multi-atlas registration using an intermediate template image

    NASA Astrophysics Data System (ADS)

    Dewey, Blake E.; Carass, Aaron; Blitz, Ari M.; Prince, Jerry L.

    2017-03-01

    Multi-atlas label fusion is an accurate but time-consuming method of labeling the human brain. Using an intermediate image as a registration target can allow researchers to reduce time constraints by storing the deformations required of the atlas images. In this paper, we investigate the effect of registration through an intermediate template image on multi-atlas label fusion and propose a novel registration technique to counteract the negative effects of through-template registration. We show that overall computation time can be decreased dramatically with minimal impact on final label accuracy and time can be exchanged for improved results in a predictable manner. We see almost complete recovery of Dice similarity over a simple through-template registration using the corrected method and still maintain a 3-4 times speed increase. Further, we evaluate the effectiveness of this method on brains of patients with normal-pressure hydrocephalus, where abnormal brain shape presents labeling difficulties, specifically the ventricular labels. Our correction method creates substantially better ventricular labeling than traditional methods and maintains the speed increase seen in healthy subjects.

  12. Evaluation of non-rigid constrained CT/CBCT registration algorithms for delineation propagation in the context of prostate cancer radiotherapy

    NASA Astrophysics Data System (ADS)

    Rubeaux, Mathieu; Simon, Antoine; Gnep, Khemara; Colliaux, Jérémy; Acosta, Oscar; de Crevoisier, Renaud; Haigron, Pascal

    2013-03-01

    Image-Guided Radiation Therapy (IGRT) aims at increasing the precision of radiation dose delivery. In the context of prostate cancer, a planning Computed Tomography (CT) image with manually defined prostate and organs at risk (OAR) delineations is usually associated with daily Cone Beam Computed Tomography (CBCT) follow-up images. The CBCT images allow to visualize the prostate position and to reposition the patient accordingly. They also should be used to evaluate the dose received by the organs at each fraction of the treatment. To do so, the first step is a prostate and OAR segmentation on the daily CBCTs, which is very timeconsuming. To simplify this task, CT to CBCT non-rigid registration could be used in order to propagate the original CT delineations in the CBCT images. For this aim, we compared several non-rigid registration methods. They are all based on the Mutual Information (MI) similarity measure, and use a BSpline transformation model. But we add different constraints to this global scheme in order to evaluate their impact on the final results. These algorithms are investigated on two real datasets, representing a total of 70 CBCT on which a reference delineation has been realized. The evaluation is led using the Dice Similarity Coefficient (DSC) as a quality criteria. The experiments show that a rigid penalty term on the bones improves the final registration result, providing high quality propagated delineations.

  13. Control over structure-specific flexibility improves anatomical accuracy for point-based deformable registration in bladder cancer radiotherapy.

    PubMed

    Wognum, S; Bondar, L; Zolnay, A G; Chai, X; Hulshof, M C C M; Hoogeman, M S; Bel, A

    2013-02-01

    Future developments in image guided adaptive radiotherapy (IGART) for bladder cancer require accurate deformable image registration techniques for the precise assessment of tumor and bladder motion and deformation that occur as a result of large bladder volume changes during the course of radiotherapy treatment. The aim was to employ an extended version of a point-based deformable registration algorithm that allows control over tissue-specific flexibility in combination with the authors' unique patient dataset, in order to overcome two major challenges of bladder cancer registration, i.e., the difficulty in accounting for the difference in flexibility between the bladder wall and tumor and the lack of visible anatomical landmarks for validation. The registration algorithm used in the current study is an extension of the symmetric-thin plate splines-robust point matching (S-TPS-RPM) algorithm, a symmetric feature-based registration method. The S-TPS-RPM algorithm has been previously extended to allow control over the degree of flexibility of different structures via a weight parameter. The extended weighted S-TPS-RPM algorithm was tested and validated on CT data (planning- and four to five repeat-CTs) of five urinary bladder cancer patients who received lipiodol injections before radiotherapy. The performance of the weighted S-TPS-RPM method, applied to bladder and tumor structures simultaneously, was compared with a previous version of the S-TPS-RPM algorithm applied to bladder wall structure alone and with a simultaneous nonweighted S-TPS-RPM registration of the bladder and tumor structures. Performance was assessed in terms of anatomical and geometric accuracy. The anatomical accuracy was calculated as the residual distance error (RDE) of the lipiodol markers and the geometric accuracy was determined by the surface distance, surface coverage, and inverse consistency errors. Optimal parameter values for the flexibility and bladder weight parameters were determined for the weighted S-TPS-RPM. The weighted S-TPS-RPM registration algorithm with optimal parameters significantly improved the anatomical accuracy as compared to S-TPS-RPM registration of the bladder alone and reduced the range of the anatomical errors by half as compared with the simultaneous nonweighted S-TPS-RPM registration of the bladder and tumor structures. The weighted algorithm reduced the RDE range of lipiodol markers from 0.9-14 mm after rigid bone match to 0.9-4.0 mm, compared to a range of 1.1-9.1 mm with S-TPS-RPM of bladder alone and 0.9-9.4 mm for simultaneous nonweighted registration. All registration methods resulted in good geometric accuracy on the bladder; average error values were all below 1.2 mm. The weighted S-TPS-RPM registration algorithm with additional weight parameter allowed indirect control over structure-specific flexibility in multistructure registrations of bladder and bladder tumor, enabling anatomically coherent registrations. The availability of an anatomically validated deformable registration method opens up the horizon for improvements in IGART for bladder cancer.

  14. Effectiveness of recruitment to a smartphone-delivered nutrition intervention in New Zealand: analysis of a randomised controlled trial.

    PubMed

    Volkova, Ekaterina; Michie, Jo; Corrigan, Callie; Sundborn, Gerhard; Eyles, Helen; Jiang, Yannan; Mhurchu, Cliona Ni

    2017-07-02

    Delivery of interventions via smartphone is a relatively new initiative in public health, and limited evidence exists regarding optimal strategies for recruitment. We describe the effectiveness of approaches used to recruit participants to a smartphone-enabled nutrition intervention trial. Internet and social media advertising, mainstream media advertising and research team networks were used to recruit New Zealand adults to a fully automated smartphone-delivered nutrition labelling trial (no face-to-face visits were required). Recruitment of Māori and Pacific participants was a key focus and ethically relevant recruitment materials and approaches were used where possible. The effectiveness of recruitment strategies was evaluated using Google Analytics, monitoring of study website registrations and randomisations, and self-reported participant data. The cost of the various strategies and associations with participant demographics were assessed. Over a period of 13 months, there were 2448 registrations on the study website, and 1357 eligible individuals were randomised into the study (55%). Facebook campaigns were the most successful recruitment strategy overall (43% of all randomised participants) and for all ethnic groups (Māori 44%, Pacific 44% and other 43%). Significant associations were observed between recruitment strategy and age (p<0.001), household size (p<0.001), ethnicity (p<0.001), gender (p=0.005) and interest in healthy eating (p=0.022). Facebook campaigns resulted in the highest absolute numbers of study registrations and randomisations (966 and 584, respectively). Network strategies and Facebook campaigns cost least per randomised participant (NZ$4 and NZ$5, respectively), whereas radio advertising costs most (NZ$179 per participant). Internet and social media advertising were the most effective and least costly approaches to recruiting participants to a smartphone-delivered trial. These approaches also reached diverse ethnic groups. However, more culturally appropriate recruitment strategies are likely to be necessary in studies where large numbers of participants from specific ethnic groups are sought. ACTRN12614000644662; Post-results. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  15. Improved image alignment method in application to X-ray images and biological images.

    PubMed

    Wang, Ching-Wei; Chen, Hsiang-Chou

    2013-08-01

    Alignment of medical images is a vital component of a large number of applications throughout the clinical track of events; not only within clinical diagnostic settings, but prominently so in the area of planning, consummation and evaluation of surgical and radiotherapeutical procedures. However, image registration of medical images is challenging because of variations on data appearance, imaging artifacts and complex data deformation problems. Hence, the aim of this study is to develop a robust image alignment method for medical images. An improved image registration method is proposed, and the method is evaluated with two types of medical data, including biological microscopic tissue images and dental X-ray images and compared with five state-of-the-art image registration techniques. The experimental results show that the presented method consistently performs well on both types of medical images, achieving 88.44 and 88.93% averaged registration accuracies for biological tissue images and X-ray images, respectively, and outperforms the benchmark methods. Based on the Tukey's honestly significant difference test and Fisher's least square difference test tests, the presented method performs significantly better than all existing methods (P ≤ 0.001) for tissue image alignment, and for the X-ray image registration, the proposed method performs significantly better than the two benchmark b-spline approaches (P < 0.001). The software implementation of the presented method and the data used in this study are made publicly available for scientific communities to use (http://www-o.ntust.edu.tw/∼cweiwang/ImprovedImageRegistration/). cweiwang@mail.ntust.edu.tw.

  16. Evaluation of an Automatic Registration-Based Algorithm for Direct Measurement of Volume Change in Tumors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sarkar, Saradwata; Johnson, Timothy D.; Ma, Bing

    2012-07-01

    Purpose: Assuming that early tumor volume change is a biomarker for response to therapy, accurate quantification of early volume changes could aid in adapting an individual patient's therapy and lead to shorter clinical trials. We investigated an image registration-based approach for tumor volume change quantification that may more reliably detect smaller changes that occur in shorter intervals than can be detected by existing algorithms. Methods and Materials: Variance and bias of the registration-based approach were evaluated using retrospective, in vivo, very-short-interval diffusion magnetic resonance imaging scans where true zero tumor volume change is unequivocally known and synthetic data, respectively. Themore » interval scans were nonlinearly registered using two similarity measures: mutual information (MI) and normalized cross-correlation (NCC). Results: The 95% confidence interval of the percentage volume change error was (-8.93% to 10.49%) for MI-based and (-7.69%, 8.83%) for NCC-based registrations. Linear mixed-effects models demonstrated that error in measuring volume change increased with increase in tumor volume and decreased with the increase in the tumor's normalized mutual information, even when NCC was the similarity measure being optimized during registration. The 95% confidence interval of the relative volume change error for the synthetic examinations with known changes over {+-}80% of reference tumor volume was (-3.02% to 3.86%). Statistically significant bias was not demonstrated. Conclusion: A low-noise, low-bias tumor volume change measurement algorithm using nonlinear registration is described. Errors in change measurement were a function of tumor volume and the normalized mutual information content of the tumor.« less

  17. The heart of the matter: Outcome reporting bias and registration status in cardio-thoracic surgery.

    PubMed

    Wiebe, Jordan; Detten, Grant; Scheckel, Caleb; Gearhart, David; Wheeler, Denna; Sanders, Donald; Vassar, Matt

    2017-01-15

    Our objective is to compare registered outcomes to published reports; to evaluate for discrepancies favoring statistically significant outcomes; to examine funding source and likelihood of outcome reporting bias; and to evaluate for any temporal trends in outcome reporting bias. PubMed was searched for randomized controlled trials published between 2008 and 2015 from 4 high impact cardio-thoracic journals: European Journal of Cardio-thoracic Surgery (EJCS), The Journal of Cardiothoracic Surgery (JCS), The Journal of Thoracic and Cardiovascular Surgery (JTCS), and Annals of Cardiothoracic Surgery (ACS). Data was collected using a standardized extraction form. We reviewed 287 articles, of which 214 (74.6%) did not meet registration criteria. Of those 214, 94 (43.9%) were published in the EJCS, 34 (15.9%) in JCS, 86 (40.2%) in JTCS, and 0 (0%) in the ACS. Of the remaining 73 articles, 34 (46.6%) had a discrepancy between the primary outcome registered and the published outcome, and 11 of the 34 reported p-values favoring the change. We also found that 12 of the 73 registrations had updated primary outcomes from the initial report to the final report. The timing of registration was an incidental finding showing 14 (19.1%) articles retrospectively registered, 29 (39.7%) registered during patient enrollment, and 30 (41.1%) registered prospectively. The results indicated that selective outcome reporting is prevalent in cardio-thoracic surgery journals. The more concerning issue, however, is the lack of registration or provision of registration number for randomized controlled trials within these journals. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  18. Investigation of the Surface Filamentary Discharge in Focus of Microwave Radiation

    DTIC Science & Technology

    2010-08-01

    microwave radiation 5a. CONTRACT NUMBER ISTC Registration No: 3784 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) Dr. Kirill...NUMBER(S) ISTC 07-7011 12. DISTRIBUTION/AVAILABILITY STATEMENT Approved for public release; distribution is unlimited. (approval given by local...contract to the International Science and Technology Center ( ISTC ), Moscow Project ISTC # 3784p (077011) Investigation of the surface filamentary

  19. Text messaging as a new method for injury registration in sports: a methodological study in elite female football.

    PubMed

    Nilstad, A; Bahr, R; Andersen, T E

    2014-02-01

    Methodological differences in epidemiologic studies have led to significant discrepancies in injury incidences reported. The aim of this study was to evaluate text messaging as a new method for injury registration in elite female football players and to compare this method with routine medical staff registration. Twelve teams comprising 228 players prospectively recorded injuries and exposure through one competitive football season. Players reported individually by answering three text messages once a week. A designated member of the medical staff conducted concurrent registrations of injuries and exposure. Injuries and exposure were compared between medical staff registrations from nine teams and their 159 affiliated players. During the football season, a total of 232 time-loss injuries were recorded. Of these, 62% were captured through individual registration only, 10% by the medical staff only, and 28% were reported through both methods. The incidence of training injuries was 3.7 per 1000 player hours when calculated from individual registration vs 2.2 from medical staff registration [rate ratio (RR): 1.7, 1.2-2.4]. For match injuries, the corresponding incidences were 18.6 vs 5.4 (RR: 3.4, 2.4-4.9), respectively. There was moderate agreement for severity classifications in injury cases reported by both methods (kappa correlation coefficient: 0.48, confidence interval: 0.30-0.66). © 2012 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  20. Coarse Point Cloud Registration by Egi Matching of Voxel Clusters

    NASA Astrophysics Data System (ADS)

    Wang, Jinhu; Lindenbergh, Roderik; Shen, Yueqian; Menenti, Massimo

    2016-06-01

    Laser scanning samples the surface geometry of objects efficiently and records versatile information as point clouds. However, often more scans are required to fully cover a scene. Therefore, a registration step is required that transforms the different scans into a common coordinate system. The registration of point clouds is usually conducted in two steps, i.e. coarse registration followed by fine registration. In this study an automatic marker-free coarse registration method for pair-wise scans is presented. First the two input point clouds are re-sampled as voxels and dimensionality features of the voxels are determined by principal component analysis (PCA). Then voxel cells with the same dimensionality are clustered. Next, the Extended Gaussian Image (EGI) descriptor of those voxel clusters are constructed using significant eigenvectors of each voxel in the cluster. Correspondences between clusters in source and target data are obtained according to the similarity between their EGI descriptors. The random sampling consensus (RANSAC) algorithm is employed to remove outlying correspondences until a coarse alignment is obtained. If necessary, a fine registration is performed in a final step. This new method is illustrated on scan data sampling two indoor scenarios. The results of the tests are evaluated by computing the point to point distance between the two input point clouds. The presented two tests resulted in mean distances of 7.6 mm and 9.5 mm respectively, which are adequate for fine registration.

Top