Ma, Weina; Yang, Liu; Lv, Yanni; Fu, Jia; Zhang, Yanmin; He, Langchong
2017-06-23
The equilibrium dissociation constant (K D ) of drug-membrane receptor affinity is the basic parameter that reflects the strength of interaction. The cell membrane chromatography (CMC) method is an effective technique to study the characteristics of drug-membrane receptor affinity. In this study, the K D value of CMC relative standard method for the determination of drug-membrane receptor affinity was established to analyze the relative K D values of drugs binding to the membrane receptors (Epidermal growth factor receptor and angiotensin II receptor). The K D values obtained by the CMC relative standard method had a strong correlation with those obtained by the frontal analysis method. Additionally, the K D values obtained by CMC relative standard method correlated with pharmacological activity of the drug being evaluated. The CMC relative standard method is a convenient and effective method to evaluate drug-membrane receptor affinity. Copyright © 2017 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Wang, J.; Shi, M.; Zheng, P.; Xue, Sh.; Peng, R.
2018-03-01
Laser-induced breakdown spectroscopy has been applied for the quantitative analysis of Ca, Mg, and K in the roots of Angelica pubescens Maxim. f. biserrata Shan et Yuan used in traditional Chinese medicine. Ca II 317.993 nm, Mg I 517.268 nm, and K I 769.896 nm spectral lines have been chosen to set up calibration models for the analysis using the external standard and artificial neural network methods. The linear correlation coefficients of the predicted concentrations versus the standard concentrations of six samples determined by the artificial neural network method are 0.9896, 0.9945, and 0.9911 for Ca, Mg, and K, respectively, which are better than for the external standard method. The artificial neural network method also gives better performance comparing with the external standard method for the average and maximum relative errors, average relative standard deviations, and most maximum relative standard deviations of the predicted concentrations of Ca, Mg, and K in the six samples. Finally, it is proved that the artificial neural network method gives better performance compared to the external standard method for the quantitative analysis of Ca, Mg, and K in the roots of Angelica pubescens.
A SIMPLE METHOD FOR EVALUATING DATA FROM AN INTERLABORATORY STUDY
Large-scale laboratory-and method-performance studies involving more than about 30 laboratories may be evaluated by calculating the HORRAT ratio for each test sample (HORRAT=[experimentally found among-laboratories relative standard deviation] divided by [relative standard deviat...
Superintendents' Beliefs and Behaviors regarding Instructional Leadership Standards Reform
ERIC Educational Resources Information Center
Lewis, Timothy; Rice, Margaret; Rice, Richard, Jr.
2011-01-01
This study examined Alabama school superintendents' perceptions of the new Alabama instructional leadership standards as related to the superintendency, and superintendents' professional needs related to the knowledge indicators in the standards. Also explored were superintendents' perceptions towards professional development delivery methods,…
Rathi, Monika; Ahrenkiel, S P; Carapella, J J; Wanlass, M W
2013-02-01
Given an unknown multicomponent alloy, and a set of standard compounds or alloys of known composition, can one improve upon popular standards-based methods for energy dispersive X-ray (EDX) spectrometry to quantify the elemental composition of the unknown specimen? A method is presented here for determining elemental composition of alloys using transmission electron microscopy-based EDX with appropriate standards. The method begins with a discrete set of related reference standards of known composition, applies multivariate statistical analysis to those spectra, and evaluates the compositions with a linear matrix algebra method to relate the spectra to elemental composition. By using associated standards, only limited assumptions about the physical origins of the EDX spectra are needed. Spectral absorption corrections can be performed by providing an estimate of the foil thickness of one or more reference standards. The technique was applied to III-V multicomponent alloy thin films: composition and foil thickness were determined for various III-V alloys. The results were then validated by comparing with X-ray diffraction and photoluminescence analysis, demonstrating accuracy of approximately 1% in atomic fraction.
Li, Yongtao; Whitaker, Joshua S; McCarty, Christina L
2012-07-06
A large volume direct aqueous injection method was developed for the analysis of iodinated haloacetic acids in drinking water by using reversed-phase liquid chromatography/electrospray ionization/tandem mass spectrometry in the negative ion mode. Both the external and internal standard calibration methods were studied for the analysis of monoiodoacetic acid, chloroiodoacetic acid, bromoiodoacetic acid, and diiodoacetic acid in drinking water. The use of a divert valve technique for the mobile phase solvent delay, along with isotopically labeled analogs used as internal standards, effectively reduced and compensated for the ionization suppression typically caused by coexisting common inorganic anions. Under the optimized method conditions, the mean absolute and relative recoveries resulting from the replicate fortified deionized water and chlorinated drinking water analyses were 83-107% with a relative standard deviation of 0.7-11.7% and 84-111% with a relative standard deviation of 0.8-12.1%, respectively. The method detection limits resulting from the external and internal standard calibrations, based on seven fortified deionized water replicates, were 0.7-2.3 ng/L and 0.5-1.9 ng/L, respectively. Copyright © 2012 Elsevier B.V. All rights reserved.
Preliminary evaluation of a gel tube agglutination major cross-match method in dogs.
Villarnovo, Dania; Burton, Shelley A; Horney, Barbara S; MacKenzie, Allan L; Vanderstichel, Raphaël
2016-09-01
A major cross-match gel tube test is available for use in dogs yet has not been clinically evaluated. This study compared cross-match results obtained using the gel tube and the standard tube methods for canine samples. Study 1 included 107 canine sample donor-recipient pairings cross-match tested with the RapidVet-H method gel tube test and compared results with the standard tube method. Additionally, 120 pairings using pooled sera containing anti-canine erythrocyte antibody at various concentrations were tested with leftover blood from a hospital population to assess sensitivity and specificity of the gel tube method in comparison with the standard method. The gel tube method had a good relative specificity of 96.1% in detecting lack of agglutination (compatibility) compared to the standard tube method. Agreement between the 2 methods was moderate. Nine of 107 pairings showed agglutination/incompatibility on either test, too few to allow reliable calculation of relative sensitivity. Fifty percent of the gel tube method results were difficult to interpret due to sample spreading in the reaction and/or negative control tubes. The RapidVet-H method agreed with the standard cross-match method on compatible samples, but detected incompatibility in some sample pairs that were compatible with the standard method. Evaluation using larger numbers of incompatible pairings is needed to assess diagnostic utility. The gel tube method results were difficult to categorize due to sample spreading. Weak agglutination reactions or other factors such as centrifuge model may be responsible. © 2016 American Society for Veterinary Clinical Pathology.
Standard line slopes as a measure of a relative matrix effect in quantitative HPLC-MS bioanalysis.
Matuszewski, B K
2006-01-18
A simple experimental approach for studying and identifying the relative matrix effect (for example "plasma-to-plasma" and/or "urine-to-urine") in quantitative analyses by HPLC-MS/MS is described. Using as a database a large number of examples of methods developed in recent years in our laboratories, the relationship between the precision of standard line slopes constructed in five different lots of a biofluid (for example plasma) and the reliability of determination of concentration of an analyte in a particular plasma lot (or subject) was examined. In addition, the precision of standard line slopes was compared when stable isotope-labeled analytes versus analogs were used as internal standards (IS). Also, in some cases, a direct comparison of standard line slopes was made when different HPLC-MS interfaces (APCI versus ESI) were used for the assay of the same compound, using the same IS and the same sample preparation and chromatographic separation conditions. In selected cases, the precision of standard line slopes in five different lots of a biofluid was compared with precision values determined five times in a single lot. The results of these studies indicated that the variability of standard line slopes in different lots of a biofluid [precision of standard line slopes expressed as coefficient of variation, CV (%)] may serve as a good indicator of a relative matrix effect and, it is suggested, this precision value should not exceed 3-4% for the method to be considered reliable and free from the relative matrix effect liability. Based on the results presented, in order to assess the relative matrix effect in bioanalytical methods, it is recommended to perform assay precision and accuracy determination in five different lots of a biofluid, instead of repeat (n=5) analysis in the same, single biofluid lot, calculate standard line slopes and precision of these slopes, and to use <3-4% slope precision value as a guide for method applicability to support clinical studies. It was also demonstrated that when stable isotope-labeled analytes were used as internal standards, the precision of standard line slopes in five different lots of a biofluid was =2.4% irrespective of the HPLC-MS interface utilized. This clearly indicated that, in all cases studied, the use of stable isotope-labeled IS eliminated relative matrix effect. Also, the utilization of the APCI interface instead of ESI led to the elimination of the relative matrix effect in all cases studied. When the precision of standard line slope values exceeds the 3-4% limit, the method may require improvements (a more efficient chromatography, a more selective extraction, a stable isotope-labeled IS instead of an analog as an IS, and/or a change in the HPLC-MS interface) to eliminate the relative matrix effect and to improve assay selectivity.
Standard test method for grindability of coal by the hardgrove-machine method
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1975-01-01
This method is used to determine the relative grindability or ease of pulverization of coals in comparison with coals chosen as standards. A prepared sample receives a definite amount of grinding energy in a miniature pulverizer, and the change in size consist is determined by sieving.
The Use of Standardized Patients to Teach Low-Literacy Communication Skills
ERIC Educational Resources Information Center
Manning, Kimberly D.; Kripalani, Sunil
2007-01-01
Objective: To describe methods for incorporating standardized patients into health literacy training programs. Methods: We discuss aspects of program development that are relatively unique to this educational context. Results: Individuals were recruited to play the role of an average adult with limited health literacy. Methods of recruitment,…
Salvati, Louis M; McClure, Sean C; Reddy, Todime M; Cellar, Nicholas A
2016-05-01
This method provides simultaneous determination of total vitamins B1, B2, B3, and B6 in infant formula and related nutritionals (adult and infant). The method was given First Action for vitamins B1, B2, and B6, but not B3, during the AOAC Annual Meeting in September 2015. The method uses acid phosphatase to dephosphorylate the phosphorylated vitamin forms. It then measures thiamine (vitamin B1); riboflavin (vitamin B2); nicotinamide and nicotinic acid (vitamin B3); and pyridoxine, pyridoxal, and pyridoxamine (vitamin B6) from digested sample extract by liquid chromatography-tandem mass spectrometry. A single-laboratory validation was performed on 14 matrixes provided by the AOAC Stakeholder Panel on Infant Formula and Adult Nutritionals (SPIFAN) to demonstrate method effectiveness. The method met requirements of the AOAC SPIFAN Standard Method Performance Requirement for each of the three vitamins, including average over-spike recovery of 99.6 ± 3.5%, average repeatability of 1.5 ± 0.8% relative standard deviation, and average intermediate precision of 3.9 ± 1.3% relative standard deviation.
Hearing Aid–Related Standards and Test Systems
Ravn, Gert; Preves, David
2015-01-01
Many documents describe standardized methods and standard equipment requirements in the field of audiology and hearing aids. These standards will ensure a uniform level and a high quality of both the methods and equipment used in audiological work. The standards create the basis for measuring performance in a reproducible manner and independent from how and when and by whom parameters have been measured. This article explains, and focuses on, relevant acoustic and electromagnetic compatibility parameters and describes several test systems available. PMID:27516709
Liu, Fang; Ren, Dequan; Guo, De-an; Pan, Yifeng; Zhang, Huzhe; Hu, Ping
2008-03-01
In this paper, a new method for liquid chromatographic fingerprint of saponins in Gynostemma pentaphyllum (THUNB.) MAKINO was developed. The G. pentaphyllum powder was defatted by Soxhlet extraction with petroleum ether and then gypenosides were extracted from the residue with methanol by sonicating. Column chromatography with macro pore resin was then used to separate and enrich gypenosides. HPLC fingerprint analysis of gypenosides fraction was performed on a C18 column, with an isocratic elution of 34% acetonitrile for 60 min at 0.8 ml/min, sample injection volume was 20 microl and the wavelength was 203 nm. To cover the lack of standard compounds, the addition of an internal standard of ginsenoside Rb2 was employed in the gypenosides fingerprint profile. The relative retention time (RRT) and relative peak area (RPA) of the gypenosides peaks in the fingerprint were calculated by setting the ginsenoside Rb2 as the marker compound. The relative standard deviation (RSDs) of RRT of five common peaks vs. ginsenoside Rb2 in precision, repeatability and stability test were less than 1%, and the RSDs of RPA were less than 5%. The method validation data proved that the proposed method for the fingerprint with internal standard of G. pentaphyllum saponins is adequate, valid and applicable. Finally, three batches of crude drug samples collected from Shanxi province were tested by following the established method.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-06-07
... ``cause or contribute to air pollution which may reasonably be anticipated to endanger public health or... National Ambient Air Quality Standards: Scope and Methods Plan for Health Risk and Exposure Assessment... Related to the Review of the National Ambient Air Quality Standards for Carbon Monoxide AGENCY...
Quantifying relative importance: Computing standardized effects in models with binary outcomes
Grace, James B.; Johnson, Darren; Lefcheck, Jonathan S.; Byrnes, Jarrett E.K.
2018-01-01
Results from simulation studies show that both the LT and OE methods of standardization support a similarly-broad range of coefficient comparisons. The LT method estimates effects that reflect underlying latent-linear propensities, while the OE method computes a linear approximation for the effects of predictors on binary responses. The contrast between assumptions for the two methods is reflected in persistently weaker standardized effects associated with OE standardization. Reliance on standard deviations for standardization (the traditional approach) is critically examined and shown to introduce substantial biases when predictors are non-Gaussian. The use of relevant ranges in place of standard deviations has the capacity to place LT and OE standardized coefficients on a more comparable scale. As ecologists address increasingly complex hypotheses, especially those that involve comparing the influences of different controlling factors (e.g., top-down versus bottom-up or biotic versus abiotic controls), comparable coefficients become a necessary component for evaluations.
This presentation will describe the U.S. EPA’s drinking water and ambient water method development program in relation to the process employed and the typical challenges encountered in developing standardized LC/MS/MS methods for chemicals of emerging concern. The EPA&rsquo...
Influence of Installation Errors On the Output Data of the Piezoelectric Vibrations Transducers
NASA Astrophysics Data System (ADS)
Kozuch, Barbara; Chelmecki, Jaroslaw; Tatara, Tadeusz
2017-10-01
The paper examines an influence of installation errors of the piezoelectric vibrations transducers on the output data. PCB Piezotronics piezoelectric accelerometers were used to perform calibrations by comparison. The measurements were performed with TMS 9155 Calibration Workstation version 5.4.0 at frequency in the range of 5Hz - 2000Hz. Accelerometers were fixed on the calibration station in a so-called back-to-back configuration in accordance with the applicable international standard - ISO 16063-21: Methods for the calibration of vibration and shock transducers - Part 21: Vibration calibration by comparison to a reference transducer. The first accelerometer was calibrated by suitable methods with traceability to a primary reference transducer. Each subsequent calibration was performed when changing one setting in relation to the original calibration. The alterations were related to negligence and failures in relation to the above-mentioned standards and operating guidelines - e.g. the sensor was not tightened or appropriate substance was not placed. Also, there was modified the method of connection which was in the standards requirements. Different kind of wax, light oil, grease and other assembly methods were used. The aim of the study was to verify the significance of standards requirements and to estimate of their validity. The authors also wanted to highlight the most significant calibration errors. Moreover, relation between various appropriate methods of the connection was demonstrated.
Standardization of Laser Methods and Techniques for Vibration Measurements and Calibrations
NASA Astrophysics Data System (ADS)
von Martens, Hans-Jürgen
2010-05-01
The realization and dissemination of the SI units of motion quantities (vibration and shock) have been based on laser interferometer methods specified in international documentary standards. New and refined laser methods and techniques developed by national metrology institutes and by leading manufacturers in the past two decades have been swiftly specified as standard methods for inclusion into in the series ISO 16063 of international documentary standards. A survey of ISO Standards for the calibration of vibration and shock transducers demonstrates the extended ranges and improved accuracy (measurement uncertainty) of laser methods and techniques for vibration and shock measurements and calibrations. The first standard for the calibration of laser vibrometers by laser interferometry or by a reference accelerometer calibrated by laser interferometry (ISO 16063-41) is on the stage of a Draft International Standard (DIS) and may be issued by the end of 2010. The standard methods with refined techniques proved to achieve wider measurement ranges and smaller measurement uncertainties than that specified in the ISO Standards. The applicability of different standardized interferometer methods to vibrations at high frequencies was recently demonstrated up to 347 kHz (acceleration amplitudes up to 350 km/s2). The relative deviations between the amplitude measurement results of the different interferometer methods that were applied simultaneously, differed by less than 1% in all cases.
Quantifying cause-related mortality by weighting multiple causes of death
Moreno-Betancur, Margarita; Lamarche-Vadel, Agathe; Rey, Grégoire
2016-01-01
Abstract Objective To investigate a new approach to calculating cause-related standardized mortality rates that involves assigning weights to each cause of death reported on death certificates. Methods We derived cause-related standardized mortality rates from death certificate data for France in 2010 using: (i) the classic method, which considered only the underlying cause of death; and (ii) three novel multiple-cause-of-death weighting methods, which assigned weights to multiple causes of death mentioned on death certificates: the first two multiple-cause-of-death methods assigned non-zero weights to all causes mentioned and the third assigned non-zero weights to only the underlying cause and other contributing causes that were not part of the main morbid process. As the sum of the weights for each death certificate was 1, each death had an equal influence on mortality estimates and the total number of deaths was unchanged. Mortality rates derived using the different methods were compared. Findings On average, 3.4 causes per death were listed on each certificate. The standardized mortality rate calculated using the third multiple-cause-of-death weighting method was more than 20% higher than that calculated using the classic method for five disease categories: skin diseases, mental disorders, endocrine and nutritional diseases, blood diseases and genitourinary diseases. Moreover, this method highlighted the mortality burden associated with certain diseases in specific age groups. Conclusion A multiple-cause-of-death weighting approach to calculating cause-related standardized mortality rates from death certificate data identified conditions that contributed more to mortality than indicated by the classic method. This new approach holds promise for identifying underrecognized contributors to mortality. PMID:27994280
Preservation of Digital Objects.
ERIC Educational Resources Information Center
Galloway, Patricia
2004-01-01
Presents a literature review that covers the following topics related to preservation of digital objects: practical examples; stakeholders; recordkeeping standards; genre-specific problems; trusted repository standards; preservation methods; preservation metadata standards; and future directions. (Contains 82 references.) (MES)
The Objective Borderline Method: A Probabilistic Method for Standard Setting
ERIC Educational Resources Information Center
Shulruf, Boaz; Poole, Phillippa; Jones, Philip; Wilkinson, Tim
2015-01-01
A new probability-based standard setting technique, the Objective Borderline Method (OBM), was introduced recently. This was based on a mathematical model of how test scores relate to student ability. The present study refined the model and tested it using 2500 simulated data-sets. The OBM was feasible to use. On average, the OBM performed well…
NASA Astrophysics Data System (ADS)
Li, Xiongwei; Wang, Zhe; Lui, Siu-Lung; Fu, Yangting; Li, Zheng; Liu, Jianming; Ni, Weidou
2013-10-01
A bottleneck of the wide commercial application of laser-induced breakdown spectroscopy (LIBS) technology is its relatively high measurement uncertainty. A partial least squares (PLS) based normalization method was proposed to improve pulse-to-pulse measurement precision for LIBS based on our previous spectrum standardization method. The proposed model utilized multi-line spectral information of the measured element and characterized the signal fluctuations due to the variation of plasma characteristic parameters (plasma temperature, electron number density, and total number density) for signal uncertainty reduction. The model was validated by the application of copper concentration prediction in 29 brass alloy samples. The results demonstrated an improvement on both measurement precision and accuracy over the generally applied normalization as well as our previously proposed simplified spectrum standardization method. The average relative standard deviation (RSD), average of the standard error (error bar), the coefficient of determination (R2), the root-mean-square error of prediction (RMSEP), and average value of the maximum relative error (MRE) were 1.80%, 0.23%, 0.992, 1.30%, and 5.23%, respectively, while those for the generally applied spectral area normalization were 3.72%, 0.71%, 0.973, 1.98%, and 14.92%, respectively.
Wu, Chunwei; Guan, Qingxiao; Wang, Shumei; Rong, Yueying
2017-01-01
Root of Panax ginseng C. A. Mey (Renseng in Chinese) is a famous Traditional Chinese Medicine. Ginsenosides are the major bioactive components. However, the shortage and high cost of some ginsenoside reference standards make it is difficult for quality control of P. ginseng . A method, single standard for determination of multicomponents (SSDMC), was developed for the simultaneous determination of nine ginsenosides in P. ginseng (ginsenoside Rg 1 , Re, Rf, Rg 2 , Rb 1 , Rc, Rb 2 , Rb 3 , Rd). The analytes were separated on Inertsil ODS-3 C18 (250 mm × 4.6 mm, 5 μm) with gradient elution of acetonitrile and water. The flow rate was 1 mL/min and detection wavelength was set at 203 nm. The feasibility and accuracy of SSDMC were checked by the external standard method, and various high-performance liquid chromatographic (HPLC) instruments and chromatographic conditions were investigated to verify its applicability. Using ginsenoside Rg 1 as the internal reference substance, the contents of other eight ginsenosides were calculated according to conversion factors (F) by HPLC. The method was validated with linearity ( r 2 ≥ 0.9990), precision (relative standard deviation [RSD] ≤2.9%), accuracy (97.5%-100.8%, RSD ≤ 1.6%), repeatability, and stability. There was no significant difference between the SSDMC method and the external standard method. New SSDMC method could be considered as an ideal mean to analyze the components for which reference standards are not readily available. A method, single standard for determination of multicomponents (SSDMC), was established by high-performance liquid chromatography for the simultaneous determination of nine ginsenosides in Panax ginseng (ginsenoside Rg1, Re, Rf, Rg2, Rb1, Rc, Rb2, Rb3, Rd)Various chromatographic conditions were investigated to verify applicability of FsThe feasibility and accuracy of SSDMC were checked by the external standard method. Abbreviations used: DRT: Different value of retention time; F: Conversion factor; HPLC: High-performance Liquid Chromatography; LOD: Limit of detection; LOQ: Limit of quantitation; PD: Percent difference; PPD: 20(S)-protopanaxadiol; PPT: 20(S)-protopanaxatriol; RSD: Relative standard deviation; SSDMC: Single Standard for Determination of Multicomponents; TCM: Traditional Chinese Medicine.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-11-08
.... Although Financial Accounting Standards Board (FASB) Accounting Standards Update No. 2010-20, Disclosures... categories and collecting ALLL and the related recorded investment amounts by impairment measurement method... measurement method for five loan categories: commercial real estate, residential real estate, commercial...
Measuring relative performance of an EDS detector using a NiO standard.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sugar, Joshua Daniel; Kotula, Paul Gabriel
2013-09-01
A method for measuring the relative performance of energy dispersive spectrometers (EDS) on a TEM is discussed. A NiO thin-film standard fabricated at Sandia CA is used. A performance parameter,, is measured and compared to values on several TEM systems.
A simple method to relate microwave radiances to upper tropospheric humidity
NASA Astrophysics Data System (ADS)
Buehler, S. A.; John, V. O.
2005-01-01
A brightness temperature (BT) transformation method can be applied to microwave data to retrieve Jacobian weighted upper tropospheric relative humidity (UTH) in a broad layer centered roughly between 6 and 8 km altitude. The UTH bias is below 4% RH, and the relative UTH bias below 20%. The UTH standard deviation is between 2 and 6.5% RH in absolute numbers, or between 10 and 27% in relative numbers. The standard deviation is dominated by the regression noise, resulting from vertical structure not accounted for by the simple transformation relation. The UTH standard deviation due to radiometric noise alone has a relative standard deviation of approximately 7% for a radiometric noise level of 1 K. The retrieval performance was shown to be of almost constant quality for all viewing angles and latitudes, except for problems at high latitudes due to surface effects. A validation of AMSU UTH against radiosonde UTH shows reasonable agreement if known systematic differences between AMSU and radiosonde are taken into account. When the method is applied to supersaturation studies, regression noise and radiometric noise could lead to an apparent supersaturation even if there were no supersaturation. For a radiometer noise level of 1 K the drop-off slope of the apparent supersaturation is 0.17% RH-1, for a noise level of 2 K the slope is 0.12% RH-1. The main conclusion from this study is that the BT transformation method is very well suited for microwave data. Its particular strength is in climatological applications where the simplicity and the a priori independence are key advantages.
Metrological activity determination of 133Ba by sum-peak absolute method
NASA Astrophysics Data System (ADS)
da Silva, R. L.; de Almeida, M. C. M.; Delgado, J. U.; Poledna, R.; Santos, A.; de Veras, E. V.; Rangel, J.; Trindade, O. L.
2016-07-01
The National Laboratory for Metrology of Ionizing Radiation provides gamma sources of radionuclide and standardized in activity with reduced uncertainties. Relative methods require standards to determine the sample activity while the absolute methods, as sum-peak, not. The activity is obtained directly with good accuracy and low uncertainties. 133Ba is used in research laboratories and on calibration of detectors for analysis in different work areas. Classical absolute methods don't calibrate 133Ba due to its complex decay scheme. The sum-peak method using gamma spectrometry with germanium detector standardizes 133Ba samples. Uncertainties lower than 1% to activity results were obtained.
Disseminating the unit of mass from multiple primary realisations
NASA Astrophysics Data System (ADS)
Nielsen, Lars
2016-12-01
When a new definition of the kilogram has been adopted in 2018 as expected, the unit of mass will be realised by the watt balance method, the x-ray crystal density method or perhaps other primary methods still to be developed. So far, the standard uncertainties associated with the available primary methods are at least one order of magnitude larger than the standard uncertainty associated with mass comparisons using mass comparators, so differences in primary realisations of the kilogram are easily detected, whereas many National Metrology Institutes would have to increase their calibration and measurement capabilities (CMCs) if they were traceable to a single primary realisation. This paper presents a scheme for obtaining traceability to multiple primary realisations of the kilogram using a small group of stainless steel 1 kg weights, which are allowed to change their masses over time in a way known to be realistic, and which are calibrated and stored in air. An analysis of the scheme shows that if the relative standard uncertainties of future primary realisations are equal to the relative standard uncertainties of the present methods used to measure the Planck constant, the unit of mass can be disseminated with a standard uncertainty less than 0.015 mg, which matches the smallest CMCs currently claimed for the calibration of 1 kg weights.
Selection of reference standard during method development using the analytical hierarchy process.
Sun, Wan-yang; Tong, Ling; Li, Dong-xiang; Huang, Jing-yi; Zhou, Shui-ping; Sun, Henry; Bi, Kai-shun
2015-03-25
Reference standard is critical for ensuring reliable and accurate method performance. One important issue is how to select the ideal one from the alternatives. Unlike the optimization of parameters, the criteria of the reference standard are always immeasurable. The aim of this paper is to recommend a quantitative approach for the selection of reference standard during method development based on the analytical hierarchy process (AHP) as a decision-making tool. Six alternative single reference standards were assessed in quantitative analysis of six phenolic acids from Salvia Miltiorrhiza and its preparations by using ultra-performance liquid chromatography. The AHP model simultaneously considered six criteria related to reference standard characteristics and method performance, containing feasibility to obtain, abundance in samples, chemical stability, accuracy, precision and robustness. The priority of each alternative was calculated using standard AHP analysis method. The results showed that protocatechuic aldehyde is the ideal reference standard, and rosmarinic acid is about 79.8% ability as the second choice. The determination results successfully verified the evaluation ability of this model. The AHP allowed us comprehensive considering the benefits and risks of the alternatives. It was an effective and practical tool for optimization of reference standards during method development. Copyright © 2015 Elsevier B.V. All rights reserved.
Mendez, Michelle A.; Popkin, Barry M.; Buckland, Genevieve; Schroder, Helmut; Amiano, Pilar; Barricarte, Aurelio; Huerta, José-María; Quirós, José R.; Sánchez, María-José; González, Carlos A
2011-01-01
Misreporting characterized by the reporting of implausible energy intakes may undermine the valid estimation of diet-disease relations, but the methods to best identify and account for misreporting are unknown. The present study compared how alternate approaches affected associations between selected dietary factors and body mass index (BMI) by using data from the European Prospective Investigation Into Cancer and Nutrition-Spain. A total of 24,332 women and 15,061 men 29–65 years of age recruited from 1992 to 1996 for whom measured height and weight and validated diet history data were available were included. Misreporters were identified on the basis of disparities between reported energy intakes and estimated requirements calculated using the original Goldberg method and 2 alternatives: one that substituted basal metabolic rate equations that are more valid at higher BMIs and another that used doubly labeled water-predicted total energy expenditure equations. Compared with results obtained using the original method, underreporting was considerably lower and overreporting higher with alternative methods, which were highly concordant. Accounting for misreporters with all methods yielded diet-BMI relations that were more consistent with expectations; alternative methods often strengthened associations. For example, among women, multivariable-adjusted differences in BMI for the highest versus lowest vegetable intake tertile (β = 0.37 (standard error, 0.07)) were neutral after adjusting with the original method (β = 0.01 (standard error, 07)) and negative using the predicted total energy expenditure method with stringent cutoffs (β = −0.15 (standard error, 0.07)). Alternative methods may yield more valid associations between diet and obesity-related outcomes. PMID:21242302
Mendez, Michelle A; Popkin, Barry M; Buckland, Genevieve; Schroder, Helmut; Amiano, Pilar; Barricarte, Aurelio; Huerta, José-María; Quirós, José R; Sánchez, María-José; González, Carlos A
2011-02-15
Misreporting characterized by the reporting of implausible energy intakes may undermine the valid estimation of diet-disease relations, but the methods to best identify and account for misreporting are unknown. The present study compared how alternate approaches affected associations between selected dietary factors and body mass index (BMI) by using data from the European Prospective Investigation Into Cancer and Nutrition-Spain. A total of 24,332 women and 15,061 men 29-65 years of age recruited from 1992 to 1996 for whom measured height and weight and validated diet history data were available were included. Misreporters were identified on the basis of disparities between reported energy intakes and estimated requirements calculated using the original Goldberg method and 2 alternatives: one that substituted basal metabolic rate equations that are more valid at higher BMIs and another that used doubly labeled water-predicted total energy expenditure equations. Compared with results obtained using the original method, underreporting was considerably lower and overreporting higher with alternative methods, which were highly concordant. Accounting for misreporters with all methods yielded diet-BMI relations that were more consistent with expectations; alternative methods often strengthened associations. For example, among women, multivariable-adjusted differences in BMI for the highest versus lowest vegetable intake tertile (β = 0.37 (standard error, 0.07)) were neutral after adjusting with the original method (β = 0.01 (standard error, 07)) and negative using the predicted total energy expenditure method with stringent cutoffs (β = -0.15 (standard error, 0.07)). Alternative methods may yield more valid associations between diet and obesity-related outcomes.
A new IRT-based standard setting method: application to eCat-listening.
García, Pablo Eduardo; Abad, Francisco José; Olea, Julio; Aguado, David
2013-01-01
Criterion-referenced interpretations of tests are highly necessary, which usually involves the difficult task of establishing cut scores. Contrasting with other Item Response Theory (IRT)-based standard setting methods, a non-judgmental approach is proposed in this study, in which Item Characteristic Curve (ICC) transformations lead to the final cut scores. eCat-Listening, a computerized adaptive test for the evaluation of English Listening, was administered to 1,576 participants, and the proposed standard setting method was applied to classify them into the performance standards of the Common European Framework of Reference for Languages (CEFR). The results showed a classification closely related to relevant external measures of the English language domain, according to the CEFR. It is concluded that the proposed method is a practical and valid standard setting alternative for IRT-based tests interpretations.
Precise determination of N-acetylcysteine in pharmaceuticals by microchip electrophoresis.
Rudašová, Marína; Masár, Marián
2016-01-01
A novel microchip electrophoresis method for the rapid and high-precision determination of N-acetylcysteine, a pharmaceutically active ingredient, in mucolytics has been developed. Isotachophoresis separations were carried out at pH 6.0 on a microchip with conductivity detection. The methods of external calibration and internal standard were used to evaluate the results. The internal standard method effectively eliminated variations in various working parameters, mainly run-to-run fluctuations of an injected volume. The repeatability and accuracy of N-acetylcysteine determination in all mucolytic preparations tested (Solmucol 90 and 200, and ACC Long 600) were more than satisfactory with the relative standard deviation and relative error values <0.7 and <1.9%, respectively. A recovery range of 99-101% of N-acetylcysteine in the analyzed pharmaceuticals predetermines the proposed method for accurate analysis as well. This work, in general, indicates analytical possibilities of microchip isotachophoresis for the quantitative analysis of simplified samples such as pharmaceuticals that contain the analyte(s) at relatively high concentrations. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
40 CFR 52.742 - Incorporation by reference.
Code of Federal Regulations, 2010 CFR
2010-07-01
... from the American Society for Testing and Materials (ASTM), 1916 Race Street, Philadelphia, PA 19103. (1) ASTM D1475-85, Standard Test Method for Density of Paint, Varnish, Lacquer, and Related Products, for § 52.741(a)(4)(i)(B)(3)(i). (2) ASTM D2369-87, Standard Test Method for Volatile Content of...
Sert, Şenol
2013-07-01
A comparison method for the determination (without sample pre-concentration) of uranium in ore by inductively coupled plasma optical emission spectrometry (ICP-OES) has been performed. The experiments were conducted using three procedures: matrix matching, plasma optimization, and internal standardization for three emission lines of uranium. Three wavelengths of Sm were tested as internal standard for the internal standardization method. The robust conditions were evaluated using applied radiofrequency power, nebulizer argon gas flow rate, and sample uptake flow rate by considering the intensity ratio of the Mg(II) 280.270 nm and Mg(I) 285.213 nm lines. Analytical characterization of method was assessed by limit of detection and relative standard deviation values. The certificated reference soil sample IAEA S-8 was analyzed, and the uranium determination at 367.007 nm with internal standardization using Sm at 359.260 nm has been shown to improve accuracy compared with other methods. The developed method was used for real uranium ore sample analysis.
Li, Xiongwei; Wang, Zhe; Fu, Yangting; Li, Zheng; Liu, Jianmin; Ni, Weidou
2014-01-01
Measurement of coal carbon content using laser-induced breakdown spectroscopy (LIBS) is limited by its low precision and accuracy. A modified spectrum standardization method was proposed to achieve both reproducible and accurate results for the quantitative analysis of carbon content in coal using LIBS. The proposed method used the molecular emissions of diatomic carbon (C2) and cyanide (CN) to compensate for the diminution of atomic carbon emissions in high volatile content coal samples caused by matrix effect. The compensated carbon line intensities were further converted into an assumed standard state with standard plasma temperature, electron number density, and total number density of carbon, under which the carbon line intensity is proportional to its concentration in the coal samples. To obtain better compensation for fluctuations of total carbon number density, the segmental spectral area was used and an iterative algorithm was applied that is different from our previous spectrum standardization calculations. The modified spectrum standardization model was applied to the measurement of carbon content in 24 bituminous coal samples. The results demonstrate that the proposed method has superior performance over the generally applied normalization methods. The average relative standard deviation was 3.21%, the coefficient of determination was 0.90, the root mean square error of prediction was 2.24%, and the average maximum relative error for the modified model was 12.18%, showing an overall improvement over the corresponding values for the normalization with segmental spectrum area, 6.00%, 0.75, 3.77%, and 15.40%, respectively.
Neutron activation analysis of certified samples by the absolute method
NASA Astrophysics Data System (ADS)
Kadem, F.; Belouadah, N.; Idiri, Z.
2015-07-01
The nuclear reactions analysis technique is mainly based on the relative method or the use of activation cross sections. In order to validate nuclear data for the calculated cross section evaluated from systematic studies, we used the neutron activation analysis technique (NAA) to determine the various constituent concentrations of certified samples for animal blood, milk and hay. In this analysis, the absolute method is used. The neutron activation technique involves irradiating the sample and subsequently performing a measurement of the activity of the sample. The fundamental equation of the activation connects several physical parameters including the cross section that is essential for the quantitative determination of the different elements composing the sample without resorting to the use of standard sample. Called the absolute method, it allows a measurement as accurate as the relative method. The results obtained by the absolute method showed that the values are as precise as the relative method requiring the use of standard sample for each element to be quantified.
Durão, Solange; Kredo, Tamara; Volmink, Jimmy
2015-06-01
To develop, assess, and maximize the sensitivity of a search strategy to identify diet and nutrition trials in PubMed using relative recall. We developed a search strategy to identify diet and nutrition trials in PubMed. We then constructed a gold standard reference set to validate the identified trials using the relative recall method. Relative recall was calculated by dividing the number of references from the gold standard our search strategy identified by the total number of references in the gold standard. Our gold standard comprised 298 trials, derived from 16 included systematic reviews. The initial search strategy identified 242 of 298 references, with a relative recall of 81.2% [95% confidence interval (CI): 76.3%, 85.5%]. We analyzed titles and abstracts of the 56 missed references for possible additional terms. We then modified the search strategy accordingly. The relative recall of the final search strategy was 88.6% (95% CI: 84.4%, 91.9%). We developed a search strategy to identify diet and nutrition trials in PubMed with a high relative recall (sensitivity). This could be useful for establishing a nutrition trials register to support the conduct of future research, including systematic reviews. Copyright © 2015 The Authors. Published by Elsevier Inc. All rights reserved.
Nursing Home Staffing Standards: Their Relationship to Nurse Staffing Levels
ERIC Educational Resources Information Center
Mueller, Christine; Arling, Greg; Kane, Robert; Bershadsky, Julie; Holland, Diane; Joy, Annika
2006-01-01
Purpose: This study reviews staffing standards from the 50 states and the District of Columbia to determine if these standards are related to nursing home staffing levels. Design and Methods: Rules and regulations for states' nursing home staffing standards were obtained for the 50 states and the District of Columbia. Nurse staffing data were…
Yarazavi, Mina; Noroozian, Ebrahim
2018-02-13
A novel sol-gel coating on a stainless-steel fiber was developed for the first time for the headspace solid-phase microextraction and determination of α-bisabolol with gas chromatography and flame ionization detection. The parameters influencing the efficiency of solid-phase microextraction process, such as extraction time and temperature, pH, and ionic strength, were optimized by the experimental design method. Under optimized conditions, the linear range was between 0.0027 and 100 μg/mL. The relative standard deviations determined at 0.01 and 1.0 μg/mL concentration levels (n = 3), respectively, were as follows: intraday relative standard deviations 3.4 and 3.3%; interday relative standard deviations 5.0 and 4.3%; and fiber-to-fiber relative standard deviations 6.0 and 3.5%. The relative recovery values were 90.3 and 101.4% at 0.01 and 1.0 μg/mL spiking levels, respectively. The proposed method was successfully applied to various real samples containing α-bisabolol. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Analytical evaluation of current starch methods used in the international sugar industry: Part I.
Cole, Marsha; Eggleston, Gillian; Triplett, Alexa
2017-08-01
Several analytical starch methods exist in the international sugar industry to mitigate starch-related processing challenges and assess the quality of traded end-products. These methods use iodometric chemistry, mostly potato starch standards, and utilize similar solubilization strategies, but had not been comprehensively compared. In this study, industrial starch methods were compared to the USDA Starch Research method using simulated raw sugars. Type of starch standard, solubilization approach, iodometric reagents, and wavelength detection affected total starch determination in simulated raw sugars. Simulated sugars containing potato starch were more accurately detected by the industrial methods, whereas those containing corn starch, a better model for sugarcane starch, were only accurately measured by the USDA Starch Research method. Use of a potato starch standard curve over-estimated starch concentrations. Among the variables studied, starch standard, solubilization approach, and wavelength detection affected the sensitivity, accuracy/precision, and limited the detection/quantification of the current industry starch methods the most. Published by Elsevier Ltd.
40 CFR 63.3951 - How do I demonstrate initial compliance with the emission limitations?
Code of Federal Regulations, 2011 CFR
2011-07-01
... PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) NATIONAL EMISSION STANDARDS FOR HAZARDOUS AIR POLLUTANTS FOR SOURCE CATEGORIES National Emission Standards for Hazardous Air Pollutants for Surface Coating..., “Standard Test Method for Density of Liquid Coatings, Inks, and Related Products” (incorporated by reference...
Internal Standards: A Source of Analytical Bias For Volatile Organic Analyte Determinations
The use of internal standards in the determination of volatile organic compounds as described in SW-846 Method 8260C introduces a potential for bias in results once the internal standards (ISTDs) are added to a sample for analysis. The bias is relative to the dissimilarity betw...
Hayashi, Kuniki; Hoshino, Tadashi; Yanai, Mitsuru; Tsuchiya, Tatsuyuki; Kumasaka, Kazunari; Kawano, Kinya
2004-06-01
It is well known that serious method-related differences exist in results of serum CA19-9, and the necessity of standardization has been pointed out. In this study, differences of serum tumor marker CA19-9 levels obtained by various immunoassay kits (CLEIA, FEIA, LPIA and RIA) were evaluated in sixty-seven clinical samples and five calibrators and the possibility to improve the inter-methodological differences were observed not only for clinical samples but also for calibrators. We supposed an assumed standard material using by a calibrator. We calculated the serum levels of CA19-9 when using the assumed standard material for three different measurement methods. We approximate the CA19-9 values using by this method. It is suggested that the obtained CA19-9 values could be approximated by recalculation with the assumed standard material would be able to correct between-method and between-laboratory discrepancies in particular systematic errors.
High-pressure liquid chromatography analysis of antibiotic susceptibility disks.
Hagel, R B; Waysek, E H; Cort, W M
1979-01-01
The analysis of antibiotic susceptibility disks by high-pressure liquid chromatography (HPLC) was investigated. Methods are presented for the potency determination of mecillinam, ampicillin, carbenicillin, and cephalothin alone and in various combinations. Good agreement between HPLC and microbiological data is observed for potency determinations with recoveries of greater than 95%. Relative standard deviations of lower than 2% are recorded for each HPLC method. HPLC methods offer improved accuracy and greater precision when compared to the standard microbiological methods of analysis for susceptibility disks. PMID:507793
Pisa, Pedro T; Landais, Edwige; Margetts, Barrie; Vorster, Hester H; Friedenreich, Christine M; Huybrechts, Inge; Martin-Prevel, Yves; Branca, Francesco; Lee, Warren T K; Leclercq, Catherine; Jerling, Johann; Zotor, Francis; Amuna, Paul; Al Jawaldeh, Ayoub; Aderibigbe, Olaide Ruth; Amoussa, Waliou Hounkpatin; Anderson, Cheryl A M; Aounallah-Skhiri, Hajer; Atek, Madjid; Benhura, Chakare; Chifamba, Jephat; Covic, Namukolo; Dary, Omar; Delisle, Hélène; El Ati, Jalila; El Hamdouchi, Asmaa; El Rhazi, Karima; Faber, Mieke; Kalimbira, Alexander; Korkalo, Liisa; Kruger, Annamarie; Ledo, James; Machiweni, Tatenda; Mahachi, Carol; Mathe, Nonsikelelo; Mokori, Alex; Mouquet-Rivier, Claire; Mutie, Catherine; Nashandi, Hilde Liisa; Norris, Shane A; Onabanjo, Oluseye Olusegun; Rambeloson, Zo; Saha, Foudjo Brice U; Ubaoji, Kingsley Ikechukwu; Zaghloul, Sahar; Slimani, Nadia
2018-01-02
To carry out an inventory on the availability, challenges, and needs of dietary assessment (DA) methods in Africa as a pre-requisite to provide evidence, and set directions (strategies) for implementing common dietary methods and support web-research infrastructure across countries. The inventory was performed within the framework of the "Africa's Study on Physical Activity and Dietary Assessment Methods" (AS-PADAM) project. It involves international institutional and African networks. An inventory questionnaire was developed and disseminated through the networks. Eighteen countries responded to the dietary inventory questionnaire. Various DA tools were reported in Africa; 24-Hour Dietary Recall and Food Frequency Questionnaire were the most commonly used tools. Few tools were validated and tested for reliability. Face-to-face interview was the common method of administration. No computerized software or other new (web) technologies were reported. No tools were standardized across countries. The lack of comparable DA methods across represented countries is a major obstacle to implement comprehensive and joint nutrition-related programmes for surveillance, programme evaluation, research, and prevention. There is a need to develop new or adapt existing DA methods across countries by employing related research infrastructure that has been validated and standardized in other settings, with the view to standardizing methods for wider use.
An ion-selective electrode method for determination of chlorine in geological materials
Aruscavage, P. J.; Campbell, E.Y.
1983-01-01
A method is presented for the determination of chlorine in geological materials, in which a chloride-selective ion electrode is used after decomposition of the sample with hydrofluoric acid and separation of chlorine in a gas-diffusion cell. Data are presented for 30 geological standard materials. The relative standard deviation of the method is estimated to be better than 8% for amounts of chloride of 10 ??g and greater. ?? 1983.
[Study on the reorganization of standards related to food contact ceramics and porcelains].
Zhang, Jianbo; Zhu, Lei; Zhang, Hong; Liu, Shan; Wang, Zhutian
2014-07-01
To solve the problem of overlap, iterance and conflict among current standards related to food contact ceramics and porcelains. To collect all the current standards related to food contact ceramics and porcelains and reorganize them following the settled principles and method and list the standards that need to be revoked, revised, incorporated, or keep valid and excluded from the food safety standard system. 19 standards were collected in this study and reorganized. The main food safety indexes in these standards were the limits for lead and cadmium that released from food contact ceramics and porcelains. There were released limits for lead and cadmium in 10 standards, including 4 horizontal standards and 6 commodity standards. The provisions in these 10 standards were in conflict. And as a result of this, the 4 horizontal standards were suggested to be incorporated and revised to one food safety standard, while the 6 commodity standards were suggested to be revised and exclude the lead and cadmium provisions. Another 7 commodity standards only referenced provisions for lead and cadmium limits from horizontal standards, and these 7 standards were suggested to be excluded from food safety standard system. There were no food safety indexes in 2 standards of the 19 standards, these standards were considered not related to food safety and no need to be reorganized. There were conflicts about the released limits of lead and cadmium among the current standards related to food contact ceramics and porcelains. So, it is necessary to a set up a new food safety standard for released lead and cadmium permissible limits which can apply to all food contact ceramics and porcelains. This food safety standard should be based on food safety risk assessment and the actual situations of manufacture and usage of food contact ceramics and porcelains. The provisions in international standards and relative standards from other countries can also provide references to this standard.
Liang, Xue; Ji, Hai-yan; Wang, Peng-xin; Rao, Zhen-hong; Shen, Bing-hui
2010-01-01
Preprocess method of multiplicative scatter correction (MSC) was used to reject noises in the original spectra produced by the environmental physical factor effectively, then the principal components of near-infrared spectroscopy were calculated by nonlinear iterative partial least squares (NIPALS) before building the back propagation artificial neural networks method (BP-ANN), and the numbers of principal components were calculated by the method of cross validation. The calculated principal components were used as the inputs of the artificial neural networks model, and the artificial neural networks model was used to find the relation between chlorophyll in winter wheat and reflective spectrum, which can predict the content of chlorophyll in winter wheat. The correlation coefficient (r) of calibration set was 0.9604, while the standard deviation (SD) and relative standard deviation (RSD) was 0.187 and 5.18% respectively. The correlation coefficient (r) of predicted set was 0.9600, and the standard deviation (SD) and relative standard deviation (RSD) was 0.145 and 4.21% respectively. It means that the MSC-ANN algorithm can reject noises in the original spectra produced by the environmental physical factor effectively and set up an exact model to predict the contents of chlorophyll in living leaves veraciously to replace the classical method and meet the needs of fast analysis of agricultural products.
Ito, Atsuo; Sogo, Yu; Yamazaki, Atsushi; Aizawa, Mamoru; Osaka, Akiyoshi; Hayakawa, Satoshi; Kikuchi, Masanori; Yamashita, Kimihiro; Tanaka, Yumi; Tadokoro, Mika; de Sena, Lídia Ágata; Buchanan, Fraser; Ohgushi, Hajime; Bohner, Marc
2015-10-01
A potential standard method for measuring the relative dissolution rate to estimate the resorbability of calcium-phosphate-based ceramics is proposed. Tricalcium phosphate (TCP), magnesium-substituted TCP (MgTCP) and zinc-substituted TCP (ZnTCP) were dissolved in a buffer solution free of calcium and phosphate ions at pH 4.0, 5.5 or 7.3 at nine research centers. Relative values of the initial dissolution rate (relative dissolution rates) were in good agreement among the centers. The relative dissolution rate coincided with the relative volume of resorption pits of ZnTCP in vitro. The relative dissolution rate coincided with the relative resorbed volume in vivo in the case of comparison between microporous MgTCPs with different Mg contents and similar porosity. However, the relative dissolution rate was in poor agreement with the relative resorbed volume in vivo in the case of comparison between microporous TCP and MgTCP due to the superimposition of the Mg-mediated decrease in TCP solubility on the Mg-mediated increase in the amount of resorption. An unambiguous conclusion could not be made as to whether the relative dissolution rate is predictive of the relative resorbed volume in vivo in the case of comparison between TCPs with different porosity. The relative dissolution rate may be useful for predicting the relative amount of resorption for calcium-phosphate-based ceramics having different solubility under the condition that the differences in the materials compared have little impact on the resorption process such as the number and activity of resorbing cells. The evaluation and subsequent optimization of the resorbability of calcium phosphate are crucial in the use of resorbable calcium phosphates. Although the resorbability of calcium phosphates has usually been evaluated in vivo, establishment of a standard in vitro method that can predict in vivo resorption is beneficial for accelerating development and commercialization of new resorbable calcium phosphate materials as well as reducing use of animals. However, there are only a few studies to propose such an in vitro method within which direct comparison was carried out between in vitro and in vivo resorption. We propose here an in vitro method based on measuring dissolution rate. The efficacy and limitations of the method were evaluated by international round-robin tests as well as comparison with in vivo resorption studies for future standardization. This study was carried out as one of Versailles Projects on Advanced Materials and Standards (VAMAS). Copyright © 2015 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.
de Macedo, A. N.; Vicente, G. H. L.; Nogueira, A. R. A.
2010-01-01
A method for the determination of pesticide residues in water and sediment was developed using the QuEChERS method followed by gas chromatography – mass spectrometry. The method was validated in terms of accuracy, specificity, linearity, detection and quantification limits. The recovery percentages obtained for the pesticides in water at different concentrations ranged from 63 to 116%, with relative standard deviations below 12%. The corresponding results from the sediment ranged from 48 to 115% with relative standard deviations below 16%. The limits of detection for the pesticides in water and sediment were below 0.003 mg L−1 and 0.02 mg kg−1, respectively. PMID:21165598
Matschat, Ralf; Hassler, Jürgen; Traub, Heike; Dette, Angelika
2005-12-01
The members of the committee NMP 264 "Chemical analysis of non-oxidic raw and basic materials" of the German Standards Institute (DIN) have organized two interlaboratory comparisons for multielement determination of trace elements in silicon carbide (SiC) powders via direct solid sampling methods. One of the interlaboratory comparisons was based on the application of inductively coupled plasma optical emission spectrometry with electrothermal vaporization (ETV ICP OES), and the other on the application of optical emission spectrometry with direct current arc (DC arc OES). The interlaboratory comparisons were organized and performed in the framework of the development of two standards related to "the determination of mass fractions of metallic impurities in powders and grain sizes of ceramic raw and basic materials" by both methods. SiC powders were used as typical examples of this category of material. The aim of the interlaboratory comparisons was to determine the repeatability and reproducibility of both analytical methods to be standardized. This was an important contribution to the practical applicability of both draft standards. Eight laboratories participated in the interlaboratory comparison with ETV ICP OES and nine in the interlaboratory comparison with DC arc OES. Ten analytes were investigated by ETV ICP OES and eleven by DC arc OES. Six different SiC powders were used for the calibration. The mass fractions of their relevant trace elements were determined after wet chemical digestion. All participants followed the analytical requirements described in the draft standards. In the calculation process, three of the calibration materials were used successively as analytical samples. This was managed in the following manner: the material that had just been used as the analytical sample was excluded from the calibration, so the five other materials were used to establish the calibration plot. The results from the interlaboratory comparisons were summarized and used to determine the repeatability and the reproducibility (expressed as standard deviations) of both methods. The calculation was carried out according to the related standard. The results are specified and discussed in this paper, as are the optimized analytical conditions determined and used by the authors of this paper. For both methods, the repeatability relative standard deviations were <25%, usually ~10%, and the reproducibility relative standard deviations were <35%, usually ~15%. These results were regarded as satifactory for both methods intended for rapid analysis of materials for which decomposition is difficult and time-consuming. Also described are some results from an interlaboratory comparison used to certify one of the materials that had been previously used for validation in both interlaboratory comparisons. Thirty laboratories (from eight countries) participated in this interlaboratory comparison for certification. As examples, accepted results are shown from laboratories that used ETV ICP OES or DC arc OES and had performed calibrations by using solutions or oxides, respectively. The certified mass fractions of the certified reference materials were also compared with the mass fractions determined in the interlaboratory comparisons performed within the framework of method standardization. Good agreement was found for most of the analytes.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sleiman, Mohamad; Chen, Sharon; Gilbert, Haley E.
A laboratory method to simulate natural exposure of roofing materials has been reported in a companion article. Here in the current article, we describe the results of an international, nine-participant interlaboratory study (ILS) conducted in accordance with ASTM Standard E691-09 to establish the precision and reproducibility of this protocol. The accelerated soiling and weathering method was applied four times by each laboratory to replicate coupons of 12 products representing a wide variety of roofing categories (single-ply membrane, factory-applied coating (on metal), bare metal, field-applied coating, asphalt shingle, modified-bitumen cap sheet, clay tile, and concrete tile). Participants reported initial and laboratory-agedmore » values of solar reflectance and thermal emittance. Measured solar reflectances were consistent within and across eight of the nine participating laboratories. Measured thermal emittances reported by six participants exhibited comparable consistency. For solar reflectance, the accelerated aging method is both repeatable and reproducible within an acceptable range of standard deviations: the repeatability standard deviation sr ranged from 0.008 to 0.015 (relative standard deviation of 1.2–2.1%) and the reproducibility standard deviation sR ranged from 0.022 to 0.036 (relative standard deviation of 3.2–5.8%). The ILS confirmed that the accelerated aging method can be reproduced by multiple independent laboratories with acceptable precision. In conclusion, this study supports the adoption of the accelerated aging practice to speed the evaluation and performance rating of new cool roofing materials.« less
Gao, Wen; Wang, Rui; Li, Dan; Liu, Ke; Chen, Jun; Li, Hui-Jun; Xu, Xiaojun; Li, Ping; Yang, Hua
2016-01-05
The flowers of Lonicera japonica Thunb. were extensively used to treat many diseases. As the demands for L. japonica increased, some related Lonicera plants were often confused or misused. Caffeoylquinic acids were always regarded as chemical markers in the quality control of L. japonica, but they could be found in all Lonicera species. Thus, a simple and reliable method for the evaluation of different Lonicera flowers is necessary to be established. In this work a method based on single standard to determine multi-components (SSDMC) combined with principal component analysis (PCA) for control and distinguish of Lonicera species flowers have been developed. Six components including three caffeoylquinic acids and three iridoid glycosides were assayed simultaneously using chlorogenic acid as the reference standard. The credibility and feasibility of the SSDMC method were carefully validated and the results demonstrated that there were no remarkable differences compared with external standard method. Finally, a total of fifty-one batches covering five Lonicera species were analyzed and PCA was successfully applied to distinguish the Lonicera species. This strategy simplifies the processes in the quality control of multiple-componential herbal medicine which effectively adapted for improving the quality control of those herbs belonging to closely related species. Copyright © 2015 Elsevier B.V. All rights reserved.
Mobile Robot and Mobile Manipulator Research Towards ASTM Standards Development.
Bostelman, Roger; Hong, Tsai; Legowik, Steven
2016-01-01
Performance standards for industrial mobile robots and mobile manipulators (robot arms onboard mobile robots) have only recently begun development. Low cost and standardized measurement techniques are needed to characterize system performance, compare different systems, and to determine if recalibration is required. This paper discusses work at the National Institute of Standards and Technology (NIST) and within the ASTM Committee F45 on Driverless Automatic Guided Industrial Vehicles. This includes standards for both terminology, F45.91, and for navigation performance test methods, F45.02. The paper defines terms that are being considered. Additionally, the paper describes navigation test methods that are near ballot and docking test methods being designed for consideration within F45.02. This includes the use of low cost artifacts that can provide alternatives to using relatively expensive measurement systems.
Mobile Robot and Mobile Manipulator Research Towards ASTM Standards Development
Bostelman, Roger; Hong, Tsai; Legowik, Steven
2017-01-01
Performance standards for industrial mobile robots and mobile manipulators (robot arms onboard mobile robots) have only recently begun development. Low cost and standardized measurement techniques are needed to characterize system performance, compare different systems, and to determine if recalibration is required. This paper discusses work at the National Institute of Standards and Technology (NIST) and within the ASTM Committee F45 on Driverless Automatic Guided Industrial Vehicles. This includes standards for both terminology, F45.91, and for navigation performance test methods, F45.02. The paper defines terms that are being considered. Additionally, the paper describes navigation test methods that are near ballot and docking test methods being designed for consideration within F45.02. This includes the use of low cost artifacts that can provide alternatives to using relatively expensive measurement systems. PMID:28690359
ERIC Educational Resources Information Center
Caruthers, Tarchell Peeples
2013-01-01
Current research shows that, despite standards-based mathematics reform, American students lag behind in mathematics achievement when compared to their counterparts in other countries. The purpose of this mixed methods study was to examine if reading level, as measured by the Scholastic Reading Inventory, is related to standards-based mathematics…
ERIC Educational Resources Information Center
Pitoniak, Mary J.; Yeld, Nan
2013-01-01
Criterion-referenced assessments have become more common around the world, with performance standards being set to differentiate different levels of student performance. However, use of standard setting methods developed in the United States may be complicated by factors related to the political and educational contexts within another country. In…
Guo-Qiang, Zhang; Yan, Huang; Licong, Cui
2017-01-01
We introduce RGT, Retrospective Ground-Truthing, as a surrogate reference standard for evaluating the performance of automated Ontology Quality Assurance (OQA) methods. The key idea of RGT is to use cumulative SNOMED CT changes derived from its regular longitudinal distributions by the official SNOMED CT editorial board as a partial, surrogate reference standard. The contributions of this paper are twofold: (1) to construct an RGT reference set for SNOMED CT relational changes; and (2) to perform a comparative evaluation of the performances of lattice, non-lattice, and randomized relational error detection methods using the standard precision, recall, and geometric measures. An RGT relational-change reference set of 32,241 IS-A changes were constructed from 5 U.S. editions of SNOMED CT from September 2014 to September 2016, with reversals and changes due to deletion or addition of new concepts excluded. 68,849 independent non-lattice fragments, 118,587 independent lattice fragments, and 446,603 relations were extracted from the SNOMED CT March 2014 distribution. Comparative performance analysis of smaller (less than 15) lattice vs. non-lattice fragments was also given to approach the more realistic setting in which such methods may be applied. Among the 32,241 IS-A changes, independent non-lattice fragments covered 52.8% changes with 26.4% precision with a G-score of 0.373. Even though this G-score is significantly lower in comparison to those in information retrieval, it breaks new ground in that such evaluations have never performed before in the highly discovery-oriented setting of OQA. PMID:29854262
Guo-Qiang, Zhang; Yan, Huang; Licong, Cui
2017-01-01
We introduce RGT, Retrospective Ground-Truthing, as a surrogate reference standard for evaluating the performance of automated Ontology Quality Assurance (OQA) methods. The key idea of RGT is to use cumulative SNOMED CT changes derived from its regular longitudinal distributions by the official SNOMED CT editorial board as a partial, surrogate reference standard. The contributions of this paper are twofold: (1) to construct an RGT reference set for SNOMED CT relational changes; and (2) to perform a comparative evaluation of the performances of lattice, non-lattice, and randomized relational error detection methods using the standard precision, recall, and geometric measures. An RGT relational-change reference set of 32,241 IS-A changes were constructed from 5 U.S. editions of SNOMED CT from September 2014 to September 2016, with reversals and changes due to deletion or addition of new concepts excluded. 68,849 independent non-lattice fragments, 118,587 independent lattice fragments, and 446,603 relations were extracted from the SNOMED CT March 2014 distribution. Comparative performance analysis of smaller (less than 15) lattice vs. non-lattice fragments was also given to approach the more realistic setting in which such methods may be applied. Among the 32,241 IS-A changes, independent non-lattice fragments covered 52.8% changes with 26.4% precision with a G-score of 0.373. Even though this G-score is significantly lower in comparison to those in information retrieval, it breaks new ground in that such evaluations have never performed before in the highly discovery-oriented setting of OQA.
Song, Mi; Chen, Zeng-Ping; Chen, Yao; Jin, Jing-Wen
2014-07-01
Liquid chromatography-mass spectrometry assays suffer from signal instability caused by the gradual fouling of the ion source, vacuum instability, aging of the ion multiplier, etc. To address this issue, in this contribution, an internal standard was added into the mobile phase. The internal standard was therefore ionized and detected together with the analytes of interest by the mass spectrometer to ensure that variations in measurement conditions and/or instrument have similar effects on the signal contributions of both the analytes of interest and the internal standard. Subsequently, based on the unique strategy of adding internal standard in mobile phase, a multiplicative effects model was developed for quantitative LC-MS assays and tested on a proof of concept model system: the determination of amino acids in water by LC-MS. The experimental results demonstrated that the proposed method could efficiently mitigate the detrimental effects of continuous signal variation, and achieved quantitative results with average relative predictive error values in the range of 8.0-15.0%, which were much more accurate than the corresponding results of conventional internal standard method based on the peak height ratio and partial least squares method (their average relative predictive error values were as high as 66.3% and 64.8%, respectively). Therefore, it is expected that the proposed method can be developed and extended in quantitative LC-MS analysis of more complex systems. Copyright © 2014 Elsevier B.V. All rights reserved.
Rosenberry, Donald O.; Stannard, David L.; Winter, Thomas C.; Martinez, Margo L.
2004-01-01
Evapotranspiration determined using the energy-budget method at a semi-permanent prairie-pothole wetland in east-central North Dakota, USA was compared with 12 other commonly used methods. The Priestley-Taylor and deBruin-Keijman methods compared best with the energy-budget values; mean differences were less than 0.1 mm d−1, and standard deviations were less than 0.3 mm d−1. Both methods require measurement of air temperature, net radiation, and heat storage in the wetland water. The Penman, Jensen-Haise, and Brutsaert-Stricker methods provided the next-best values for evapotranspiration relative to the energy-budget method. The mass-transfer, deBruin, and Stephens-Stewart methods provided the worst comparisons; the mass-transfer and deBruin comparisons with energy-budget values indicated a large standard deviation, and the deBruin and Stephens-Stewart comparisons indicated a large bias. The Jensen-Haise method proved to be cost effective, providing relatively accurate comparisons with the energy-budget method (mean difference=0.44 mm d−1, standard deviation=0.42 mm d−1) and requiring only measurements of air temperature and solar radiation. The Mather (Thornthwaite) method is the simplest, requiring only measurement of air temperature, and it provided values that compared relatively well with energy-budget values (mean difference=0.47 mm d−1, standard deviation=0.56 mm d−1). Modifications were made to several of the methods to make them more suitable for use in prairie wetlands. The modified Makkink, Jensen-Haise, and Stephens-Stewart methods all provided results that were nearly as close to energy-budget values as were the Priestley-Taylor and deBruin-Keijman methods, and all three of these modified methods only require measurements of air temperature and solar radiation. The modified Hamon method provided values that were within 20 percent of energy-budget values during 95 percent of the comparison periods, and it only requires measurement of air temperature. The mass-transfer coefficient, associated with the commonly used mass-transfer method, varied seasonally, with the largest values occurring during summer.
Methods for estimating flood frequency in Montana based on data through water year 1998
Parrett, Charles; Johnson, Dave R.
2004-01-01
Annual peak discharges having recurrence intervals of 2, 5, 10, 25, 50, 100, 200, and 500 years (T-year floods) were determined for 660 gaged sites in Montana and in adjacent areas of Idaho, Wyoming, and Canada, based on data through water year 1998. The updated flood-frequency information was subsequently used in regression analyses, either ordinary or generalized least squares, to develop equations relating T-year floods to various basin and climatic characteristics, equations relating T-year floods to active-channel width, and equations relating T-year floods to bankfull width. The equations can be used to estimate flood frequency at ungaged sites. Montana was divided into eight regions, within which flood characteristics were considered to be reasonably homogeneous, and the three sets of regression equations were developed for each region. A measure of the overall reliability of the regression equations is the average standard error of prediction. The average standard errors of prediction for the equations based on basin and climatic characteristics ranged from 37.4 percent to 134.1 percent. Average standard errors of prediction for the equations based on active-channel width ranged from 57.2 percent to 141.3 percent. Average standard errors of prediction for the equations based on bankfull width ranged from 63.1 percent to 155.5 percent. In most regions, the equations based on basin and climatic characteristics generally had smaller average standard errors of prediction than equations based on active-channel or bankfull width. An exception was the Southeast Plains Region, where all equations based on active-channel width had smaller average standard errors of prediction than equations based on basin and climatic characteristics or bankfull width. Methods for weighting estimates derived from the basin- and climatic-characteristic equations and the channel-width equations also were developed. The weights were based on the cross correlation of residuals from the different methods and the average standard errors of prediction. When all three methods were combined, the average standard errors of prediction ranged from 37.4 percent to 120.2 percent. Weighting of estimates reduced the standard errors of prediction for all T-year flood estimates in four regions, reduced the standard errors of prediction for some T-year flood estimates in two regions, and provided no reduction in average standard error of prediction in two regions. A computer program for solving the regression equations, weighting estimates, and determining reliability of individual estimates was developed and placed on the USGS Montana District World Wide Web page. A new regression method, termed Region of Influence regression, also was tested. Test results indicated that the Region of Influence method was not as reliable as the regional equations based on generalized least squares regression. Two additional methods for estimating flood frequency at ungaged sites located on the same streams as gaged sites also are described. The first method, based on a drainage-area-ratio adjustment, is intended for use on streams where the ungaged site of interest is located near a gaged site. The second method, based on interpolation between gaged sites, is intended for use on streams that have two or more streamflow-gaging stations.
Management of work-related stress by Finnish occupational physicians.
Kinnunen-Amoroso, M; Liira, J
2013-07-01
Occupational stress is a serious threat to the well-being of employees and organizations and may cause ill-health and loss of productivity. Determining the methods that occupational health (OH) services and employers use to manage work-related stress can help to detect both barriers and facilitating factors for effective stress management. To examine stress management methods used by OH physicians in Finland. Anonymous, self-administered e-mail questionnaire to Finnish OH physicians. A total of 222 OH physicians responded. Neither OH services nor their client organizations used standardized tools to assess or manage work-related stress. Work-related stress was assessed using patient interviews. Physicians reported that the main method used to manage occupational stress was supporting the individual employee. Half of the physicians attempted to involve workplaces in stress management by asking their patients to contact their supervisors regarding stress issues. In order to tackle work-related stress consistently and effectively employers and OH services should have agreed standardized protocols for managing stress in the workplace.
A review of the quantum current standard
NASA Astrophysics Data System (ADS)
Kaneko, Nobu-Hisa; Nakamura, Shuji; Okazaki, Yuma
2016-03-01
The electric current, voltage, and resistance standards are the most important standards related to electricity and magnetism. Of these three standards, only the ampere, which is the unit of electric current, is an International System of Units (SI) base unit. However, even with modern technology, relatively large uncertainty exists regarding the generation and measurement of current. As a result of various innovative techniques based on nanotechnology and novel materials, new types of junctions for quantum current generation and single-electron current sources have recently been proposed. These newly developed methods are also being used to investigate the consistency of the three quantum electrical effects, i.e. the Josephson, quantum Hall, and single-electron tunneling effects, which are also known as ‘the quantum metrology triangle’. This article describes recent research and related developments regarding current standards and quantum-metrology-triangle experiments.
Jenke, Dennis; Sadain, Salma; Nunez, Karen; Byrne, Frances
2007-01-01
The performance of an ion chromatographic method for measuring citrate and phosphate in pharmaceutical solutions is evaluated. Performance characteristics examined include accuracy, precision, specificity, response linearity, robustness, and the ability to meet system suitability criteria. In general, the method is found to be robust within reasonable deviations from its specified operating conditions. Analytical accuracy is typically 100 +/- 3%, and short-term precision is not more than 1.5% relative standard deviation. The instrument response is linear over a range of 50% to 150% of the standard preparation target concentrations (12 mg/L for phosphate and 20 mg/L for citrate), and the results obtained using a single-point standard versus a calibration curve are essentially equivalent. A small analytical bias is observed and ascribed to the relative purity of the differing salts, used as raw materials in tested finished products and as reference standards in the analytical method. The assay is specific in that no phosphate or citrate peaks are observed in a variety of method-related solutions and matrix blanks (with and without autoclaving). The assay with manual preparation of the eluents is sensitive to the composition of the eluent in the sense that the eluent must be effectively degassed and protected from CO(2) ingress during use. In order for the assay to perform effectively, extensive system equilibration and conditioning is required. However, a properly conditioned and equilibrated system can be used to test a number of samples via chromatographic runs that include many (> 50) injections.
Wang, Wenguang; Ma, Xiaoli; Guo, Xiaoyu; Zhao, Mingbo; Tu, Pengfei; Jiang, Yong
2015-09-18
In order to solve the bottleneck of reference standards shortage for comprehensive quality control of traditional Chinese medicines (TCMs), a series of strategies, including one single reference standard to determine multi-compounds (SSDMC), quantitative analysis by standardized reference extract (QASRE), and quantitative nuclear magnetic resonance spectroscopy (qNMR) were proposed, and Mahoniae Caulis was selected as an example to develop and validate these methods for simultaneous determination of four alkaloids, columbamine, jatrorrhizine, palmatine, and berberine. Comprehensive comparisons among these methods and with the conventional external standard method (ESM) were carried out. The relative expanded uncertainty of measurement was firstly used to compare their credibility. The results showed that all these three new developed methods can accurately accomplish the quantification by using only one purified reference standard, but each of them has its own advantages and disadvantages as well as the specific application scope, which were also discussed in detail in this paper. Copyright © 2015 Elsevier B.V. All rights reserved.
Vialaret, Jérôme; Picas, Alexia; Delaby, Constance; Bros, Pauline; Lehmann, Sylvain; Hirtz, Christophe
2018-06-01
Hepcidin-25 peptide is a biomarker which is known to have considerable clinical potential for diagnosing iron-related diseases. Developing analytical methods for the absolute quantification of hepcidin is still a real challenge, however, due to the sensitivity, specificity and reproducibility issues involved. In this study, we compare and discuss two MS-based assays for quantifying hepcidin, which differ only in terms of the type of liquid chromatography (nano LC/MS versus standard LC/MS) involved. The same sample preparation, the same internal standards and the same MS analyzer were used with both approaches. In the field of proteomics, nano LC chromatography is generally known to be more sensitive and less robust than standard LC methods. In this study, we established that the performances of the standard LC method are equivalent to those of our previously developed nano LC method. Although the analytical performances were very similar in both cases. The standard-flow platform therefore provides the more suitable alternative for accurately determining hepcidin in clinical settings. Copyright © 2018 Elsevier B.V. All rights reserved.
[Determination of acetochlor and oxyfluorfen by capillary gas chromatography].
Xiang, Wen-Sheng; Wang, Xiang-Jing; Wang, Jing; Wang, Qing
2002-09-01
A method is described for the determination of acetochlor and oxyfluorfen by capillary gas chromatography with FID and an SE-30 capillary column (60 m x 0.53 mm i. d., 1.5 microm), using dibutyl phthalate as the internal standard. The standard deviations for acetochlor and oxyfluorfen concentration(mass fraction) were 0.44% and 0.47% respectively. The relative standard deviations for acetochlor and oxyfluorfen were 0.79% and 0.88% and the average recoveries for acetochlor and oxyfluorfen were 99.3% and 101.1% respectively. The method is simple, rapid and accurate.
Voluntary Product Standard PS 72-76: Toy Safety.
ERIC Educational Resources Information Center
National Bureau of Standards (DOC), Washington, DC.
The purpose of this voluntary product standard is to establish nationally recognized safety requirements and test methods for toys intended for use by children in age groups through 14 years. The standard relates to possible hazards that may not be readily recognized and which may be encountered in,normal use or after reasonably foreseeable abuse.…
ERIC Educational Resources Information Center
Seo, Hyojeong; Shaw, Leslie A.; Shogren, Karrie A.; Lang, Kyle M.; Little, Todd D.
2017-01-01
This article demonstrates the use of structural equation modeling to develop norms for a translated version of a standardized scale, the Supports Intensity Scale-Children's Version (SIS-C). The latent variable norming method proposed is useful when the standardization sample for a translated version is relatively small to derive norms…
Research on Generating Method of Embedded Software Test Document Based on Dynamic Model
NASA Astrophysics Data System (ADS)
Qu, MingCheng; Wu, XiangHu; Tao, YongChao; Liu, Ying
2018-03-01
This paper provides a dynamic model-based test document generation method for embedded software that provides automatic generation of two documents: test requirements specification documentation and configuration item test documentation. This method enables dynamic test requirements to be implemented in dynamic models, enabling dynamic test demand tracking to be easily generated; able to automatically generate standardized, standardized test requirements and test documentation, improved document-related content inconsistency and lack of integrity And other issues, improve the efficiency.
Xie, Wei-Qi; Gong, Yi-Xian; Yu, Kong-Xian
2018-06-01
An automated and accurate headspace gas chromatographic (HS-GC) technique was investigated for rapidly quantifying water content in edible oils. In this method, multiple headspace extraction (MHE) procedures were used to analyse the integrated water content from the edible oil sample. A simple vapour phase calibration technique with an external vapour standard was used to calibrate both the water content in the gas phase and the total weight of water in edible oil sample. After that the water in edible oils can be quantified. The data showed that the relative standard deviation of the present HS-GC method in the precision test was less than 1.13%, the relative differences between the new method and a reference method (i.e. the oven-drying method) were no more than 1.62%. The present HS-GC method is automated, accurate, efficient, and can be a reliable tool for quantifying water content in edible oil related products and research. © 2017 Society of Chemical Industry. © 2017 Society of Chemical Industry.
McClure, Foster D; Lee, Jung K
2005-01-01
Sample size formulas are developed to estimate the repeatability and reproducibility standard deviations (Sr and S(R)) such that the actual error in (Sr and S(R)) relative to their respective true values, sigmar and sigmaR, are at predefined levels. The statistical consequences associated with AOAC INTERNATIONAL required sample size to validate an analytical method are discussed. In addition, formulas to estimate the uncertainties of (Sr and S(R)) were derived and are provided as supporting documentation. Formula for the Number of Replicates Required for a Specified Margin of Relative Error in the Estimate of the Repeatability Standard Deviation.
Koyama, Kazuo; Miyazaki, Kinuko; Abe, Kousuke; Egawa, Yoshitsugu; Fukazawa, Toru; Kitta, Tadashi; Miyashita, Takashi; Nezu, Toru; Nohara, Hidenori; Sano, Takashi; Takahashi, Yukinari; Taniguchi, Hideji; Yada, Hiroshi; Yamazaki, Kumiko; Watanabe, Yomi
2017-06-01
An indirect enzymatic analysis method for the quantification of fatty acid esters of 2-/3-monochloro-1,2-propanediol (2/3-MCPD) and glycidol was developed, using the deuterated internal standard of each free-form component. A statistical method for calibration and quantification of 2-MCPD-d 5 , which is difficult to obtain, is substituted by 3-MCPD-d 5 used for calculation of 3-MCPD. Using data from a previous collaborative study, the current method for the determination of 2-MCPD content using 2-MCPD-d 5 was compared to three alternative new methods using 3-MCPD-d 5 . The regression analysis showed that the alternative methods were unbiased compared to the current method. The relative standard deviation (RSD R ) among the testing laboratories was ≤ 15% and the Horwitz ratio was ≤ 1.0, a satisfactory value.
Comparative assessment of three standardized robotic surgery training methods.
Hung, Andrew J; Jayaratna, Isuru S; Teruya, Kara; Desai, Mihir M; Gill, Inderbir S; Goh, Alvin C
2013-10-01
To evaluate three standardized robotic surgery training methods, inanimate, virtual reality and in vivo, for their construct validity. To explore the concept of cross-method validity, where the relative performance of each method is compared. Robotic surgical skills were prospectively assessed in 49 participating surgeons who were classified as follows: 'novice/trainee': urology residents, previous experience <30 cases (n = 38) and 'experts': faculty surgeons, previous experience ≥30 cases (n = 11). Three standardized, validated training methods were used: (i) structured inanimate tasks; (ii) virtual reality exercises on the da Vinci Skills Simulator (Intuitive Surgical, Sunnyvale, CA, USA); and (iii) a standardized robotic surgical task in a live porcine model with performance graded by the Global Evaluative Assessment of Robotic Skills (GEARS) tool. A Kruskal-Wallis test was used to evaluate performance differences between novices and experts (construct validity). Spearman's correlation coefficient (ρ) was used to measure the association of performance across inanimate, simulation and in vivo methods (cross-method validity). Novice and expert surgeons had previously performed a median (range) of 0 (0-20) and 300 (30-2000) robotic cases, respectively (P < 0.001). Construct validity: experts consistently outperformed residents with all three methods (P < 0.001). Cross-method validity: overall performance of inanimate tasks significantly correlated with virtual reality robotic performance (ρ = -0.7, P < 0.001) and in vivo robotic performance based on GEARS (ρ = -0.8, P < 0.0001). Virtual reality performance and in vivo tissue performance were also found to be strongly correlated (ρ = 0.6, P < 0.001). We propose the novel concept of cross-method validity, which may provide a method of evaluating the relative value of various forms of skills education and assessment. We externally confirmed the construct validity of each featured training tool. © 2013 BJU International.
The role of explicit and implicit standards in visual speed discrimination.
Norman, J Farley; Pattison, Kristina F; Norman, Hideko F; Craft, Amy E; Wiesemann, Elizabeth Y; Taylor, M Jett
2008-01-01
Five experiments were designed to investigate visual speed discrimination. Variations of the method of constant stimuli were used to obtain speed discrimination thresholds in experiments 1, 2, 4, and 5, while the method of single stimuli was used in experiment 3. The observers' thresholds were significantly influenced by the choice of psychophysical method and by changes in the standard speed. The observers' judgments were unaffected, however, by changes in the magnitude of random variations in stimulus duration, reinforcing the conclusions of Lappin et al (1975 Journal of Experimental Psychology: Human Perception and Performance 1 383 394). When an implicit standard was used, the observers produced relatively low discrimination thresholds (7.0% of the standard speed), verifying the results of McKee (1981 Vision Research 21 491-500). When an explicit standard was used in a 2AFC variant of the method of constant stimuli, however, the observers' discrimination thresholds increased by 74% (to 12.2%), resembling the high thresholds obtained by Mandriota et al (1962 Science 138 437-438). A subsequent signal-detection analysis revealed that the observers' actual sensitivities to differences in speed were in fact equivalent for both psychophysical methods. The formation of an implicit standard in the method of single stimuli allows human observers to make judgments of speed that are as precise as those obtained when explicit standards are available.
Chen, Yibin; Chen, Jiaxi; Chen, Xuan; Wang, Min; Wang, Wei
2015-01-01
A new method of uniform sampling is evaluated in this paper. The items and indexes were adopted to evaluate the rationality of the uniform sampling. The evaluation items included convenience of operation, uniformity of sampling site distribution, and accuracy and precision of measured results. The evaluation indexes included operational complexity, occupation rate of sampling site in a row and column, relative accuracy of pill weight, and relative deviation of pill weight. They were obtained from three kinds of drugs with different shape and size by four kinds of sampling methods. Gray correlation analysis was adopted to make the comprehensive evaluation by comparing it with the standard method. The experimental results showed that the convenience of uniform sampling method was 1 (100%), odds ratio of occupation rate in a row and column was infinity, relative accuracy was 99.50-99.89%, reproducibility RSD was 0.45-0.89%, and weighted incidence degree exceeded the standard method. Hence, the uniform sampling method was easy to operate, and the selected samples were distributed uniformly. The experimental results demonstrated that the uniform sampling method has good accuracy and reproducibility, which can be put into use in drugs analysis.
Jha, Abhinav K.; Mena, Esther; Caffo, Brian; Ashrafinia, Saeed; Rahmim, Arman; Frey, Eric; Subramaniam, Rathan M.
2017-01-01
Abstract. Recently, a class of no-gold-standard (NGS) techniques have been proposed to evaluate quantitative imaging methods using patient data. These techniques provide figures of merit (FoMs) quantifying the precision of the estimated quantitative value without requiring repeated measurements and without requiring a gold standard. However, applying these techniques to patient data presents several practical difficulties including assessing the underlying assumptions, accounting for patient-sampling-related uncertainty, and assessing the reliability of the estimated FoMs. To address these issues, we propose statistical tests that provide confidence in the underlying assumptions and in the reliability of the estimated FoMs. Furthermore, the NGS technique is integrated within a bootstrap-based methodology to account for patient-sampling-related uncertainty. The developed NGS framework was applied to evaluate four methods for segmenting lesions from F-Fluoro-2-deoxyglucose positron emission tomography images of patients with head-and-neck cancer on the task of precisely measuring the metabolic tumor volume. The NGS technique consistently predicted the same segmentation method as the most precise method. The proposed framework provided confidence in these results, even when gold-standard data were not available. The bootstrap-based methodology indicated improved performance of the NGS technique with larger numbers of patient studies, as was expected, and yielded consistent results as long as data from more than 80 lesions were available for the analysis. PMID:28331883
Luo, Zuliang; Kong, Weijun; Qiu, Feng; Yang, Meihua; Li, Qian; Wei, Riwei; Yang, Xiaoli; Qin, Jieping
2013-02-01
A simple and sensitive HPLC coupled with photodiode array (HPLC-PDA) method was developed for simultaneous determination of seven lignans in Justicia procumbens using relative response factors (RRFs). The chromatographic separation was performed on a Shiseido Capcell Pak C(18) column (250 × 4.6 mm id, 5 μm), a gradient elution of acetonitrile/water, and a photodiode array detector. The column temperature was maintained at 35°C and the detection wavelength was set at 256 nm. Chinensinaphthol methyl ether was selected as the reference compound for calculating the relative response factors of the lignans. It has shown that the RRFs for lignans are quite similar at 256 nm of detection under different analytical conditions (different columns and HPLC instruments). Using RRFs, not every lignan is needed as a reference standard, making the method ideal for rapid, routine analysis, especially for those laboratories where lignans standards are not readily available. An economic and practicable HPLC method using RRFs was established for the determination of seven lignans in J. procumbens. This method not only can determine multiple indexes in traditional Chinese medicines (TCMs) simultaneously, but also resolve the problem of lacking of chemical standards. It will be a good quality evaluation method and pattern for TCMs. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
This standard operating procedure describes the method used for the determination of target analytes in sample extracts and related quality assurance/quality control sample extracts generated in the CTEPP study.
Non-invasive prediction of forthcoming cirrhosis-related complications
Kang, Wonseok; Kim, Seung Up; Ahn, Sang Hoon
2014-01-01
In patients with chronic liver diseases, identification of significant liver fibrosis and cirrhosis is essential for determining treatment strategies, assessing therapeutic response, and stratifying long-term prognosis. Although liver biopsy remains the reference standard for evaluating the extent of liver fibrosis in patients with chronic liver diseases, several non-invasive methods have been developed as alternatives to liver biopsies. Some of these non-invasive methods have demonstrated clinical accuracy for diagnosing significant fibrosis or cirrhosis in many cross-sectional studies with the histological fibrosis stage as a reference standard. However, non-invasive methods cannot be fully validated through cross-sectional studies since liver biopsy is not a perfect surrogate endpoint marker. Accordingly, recent studies have focused on assessing the performance of non-invasive methods through long-term, longitudinal, follow-up studies with solid clinical endpoints related to advanced stages of liver fibrosis and cirrhosis. As a result, current view is that these alternative methods can independently predict future cirrhosis-related complications, such as hepatic decompensation, liver failure, hepatocellular carcinoma, or liver-related death. The clinical role of non-invasive models seems to be shifting from a simple tool for predicting the extent of fibrosis to a surveillance tool for predicting future liver-related events. In this article, we will summarize recent longitudinal studies of non-invasive methods for predicting forthcoming complications related to liver cirrhosis and discuss the clinical value of currently available non-invasive methods based on evidence from the literature. PMID:24627597
Chen, Jing; Wang, Shu-Mei; Meng, Jiang; Sun, Fei; Liang, Sheng-Wang
2013-05-01
To establish a new method for quality evaluation and validate its feasibilities by simultaneous quantitative assay of five alkaloids in Sophora flavescens. The new quality evaluation method, quantitative analysis of multi-components by single marker (QAMS), was established and validated with S. flavescens. Five main alkaloids, oxymatrine, sophocarpine, matrine, oxysophocarpine and sophoridine, were selected as analytes to evaluate the quality of rhizome of S. flavescens, and the relative correction factor has good repeatibility. Their contents in 21 batches of samples, collected from different areas, were determined by both external standard method and QAMS. The method was evaluated by comparison of the quantitative results between external standard method and QAMS. No significant differences were found in the quantitative results of five alkaloids in 21 batches of S. flavescens determined by external standard method and QAMS. It is feasible and suitable to evaluate the quality of rhizome of S. flavescens by QAMS.
Martin, Jeffrey D.
2002-01-01
Correlation analysis indicates that for most pesticides and concentrations, pooled estimates of relative standard deviation rather than pooled estimates of standard deviation should be used to estimate variability because pooled estimates of relative standard deviation are less affected by heteroscedasticity. The 2 Variability of Pesticide Detections and Concentrations in Field Replicate Water Samples, 1992–97 median pooled relative standard deviation was calculated for all pesticides to summarize the typical variability for pesticide data collected for the NAWQA Program. The median pooled relative standard deviation was 15 percent at concentrations less than 0.01 micrograms per liter (µg/L), 13 percent at concentrations near 0.01 µg/L, 12 percent at concentrations near 0.1 µg/L, 7.9 percent at concentrations near 1 µg/L, and 2.7 percent at concentrations greater than 5 µg/L. Pooled estimates of standard deviation or relative standard deviation presented in this report are larger than estimates based on averages, medians, smooths, or regression of the individual measurements of standard deviation or relative standard deviation from field replicates. Pooled estimates, however, are the preferred method for characterizing variability because they provide unbiased estimates of the variability of the population. Assessments of variability based on standard deviation (rather than variance) underestimate the true variability of the population. Because pooled estimates of variability are larger than estimates based on other approaches, users of estimates of variability must be cognizant of the approach used to obtain the estimate and must use caution in the comparison of estimates based on different approaches.
Rudzki, Piotr J; Gniazdowska, Elżbieta; Buś-Kwaśnik, Katarzyna
2018-06-05
Liquid chromatography coupled to mass spectrometry (LC-MS) is a powerful tool for studying pharmacokinetics and toxicokinetics. Reliable bioanalysis requires the characterization of the matrix effect, i.e. influence of the endogenous or exogenous compounds on the analyte signal intensity. We have compared two methods for the quantitation of matrix effect. The CVs(%) of internal standard normalized matrix factors recommended by the European Medicines Agency were evaluated against internal standard normalized relative matrix effects derived from Matuszewski et al. (2003). Both methods use post-extraction spiked samples, but matrix factors require also neat solutions. We have tested both approaches using analytes of diverse chemical structures. The study did not reveal relevant differences in the results obtained with both calculation methods. After normalization with the internal standard, the CV(%) of the matrix factor was on average 0.5% higher than the corresponding relative matrix effect. The method adopted by the European Medicines Agency seems to be slightly more conservative in the analyzed datasets. Nine analytes of different structures enabled a general overview of the problem, still, further studies are encouraged to confirm our observations. Copyright © 2018 Elsevier B.V. All rights reserved.
Lee, Jungmin; Durst, Robert W; Wrolstad, Ronald E
2005-01-01
This collaborative study was conducted to determine the total monomeric anthocyanin concentration by the pH differential method, which is a rapid and simple spectrophotometric method based on the anthocyanin structural transformation that occurs with a change in pH (colored at pH 1.0 and colorless at pH 4.5). Eleven collaborators representing commercial laboratories, academic institutions, and government laboratories participated. Seven Youden pair materials representing fruit juices, beverages, natural colorants, and wines were tested. The repeatability relative standard deviation (RSDr) varied from 1.06 to 4.16%. The reproducibility relative standard deviation (RSDR) ranged from 2.69 to 10.12%. The HorRat values were < or = 1.33 for all materials. The Study Director recommends that the method be adopted Official First Action.
Evaluation on determination of iodine in coal by energy dispersive X-ray fluorescence
Wang, B.; Jackson, J.C.; Palmer, C.; Zheng, B.; Finkelman, R.B.
2005-01-01
A quick and inexpensive method of relative high iodine determination from coal samples was evaluated. Energy dispersive X-ray fluorescence (EDXRF) provided a detection limit of about 14 ppm (3 times of standard deviations of the blank sample), without any complex sample preparation. An analytical relative standard deviation of 16% was readily attainable for coal samples. Under optimum conditions, coal samples with iodine concentrations higher than 5 ppm can be determined using this EDXRF method. For the time being, due to the general iodine concentrations of coal samples lower than 5 ppm, except for some high iodine content coal, this method can not effectively been used for iodine determination. More work needed to meet the requirement of determination of iodine from coal samples for this method. Copyright ?? 2005 by The Geochemical Society of Japan.
Neighbors, Charles J; Barnett, Nancy P; Rohsenow, Damaris J; Colby, Suzanne M; Monti, Peter M
2010-05-01
Brief interventions in the emergency department targeting risk-taking youth show promise to reduce alcohol-related injury. This study models the cost-effectiveness of a motivational interviewing-based intervention relative to brief advice to stop alcohol-related risk behaviors (standard care). Average cost-effectiveness ratios were compared between conditions. In addition, a cost-utility analysis examined the incremental cost of motivational interviewing per quality-adjusted life year gained. Microcosting methods were used to estimate marginal costs of motivational interviewing and standard care as well as two methods of patient screening: standard emergency-department staff questioning and proactive outreach by counseling staff. Average cost-effectiveness ratios were computed for drinking and driving, injuries, vehicular citations, and negative social consequences. Using estimates of the marginal effect of motivational interviewing in reducing drinking and driving, estimates of traffic fatality risk from drinking-and-driving youth, and national life tables, the societal costs per quality-adjusted life year saved by motivational interviewing relative to standard care were also estimated. Alcohol-attributable traffic fatality risks were estimated using national databases. Intervention costs per participant were $81 for standard care, $170 for motivational interviewing with standard screening, and $173 for motivational interviewing with proactive screening. The cost-effectiveness ratios for motivational interviewing were more favorable than standard care across all study outcomes and better for men than women. The societal cost per quality-adjusted life year of motivational interviewing was $8,795. Sensitivity analyses indicated that results were robust in terms of variability in parameter estimates. This brief intervention represents a good societal investment compared with other commonly adopted medical interventions.
Allen, Robert C; Rutan, Sarah C
2011-10-31
Simulated and experimental data were used to measure the effectiveness of common interpolation techniques during chromatographic alignment of comprehensive two-dimensional liquid chromatography-diode array detector (LC×LC-DAD) data. Interpolation was used to generate a sufficient number of data points in the sampled first chromatographic dimension to allow for alignment of retention times from different injections. Five different interpolation methods, linear interpolation followed by cross correlation, piecewise cubic Hermite interpolating polynomial, cubic spline, Fourier zero-filling, and Gaussian fitting, were investigated. The fully aligned chromatograms, in both the first and second chromatographic dimensions, were analyzed by parallel factor analysis to determine the relative area for each peak in each injection. A calibration curve was generated for the simulated data set. The standard error of prediction and percent relative standard deviation were calculated for the simulated peak for each technique. The Gaussian fitting interpolation technique resulted in the lowest standard error of prediction and average relative standard deviation for the simulated data. However, upon applying the interpolation techniques to the experimental data, most of the interpolation methods were not found to produce statistically different relative peak areas from each other. While most of the techniques were not statistically different, the performance was improved relative to the PARAFAC results obtained when analyzing the unaligned data. Copyright © 2011 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Kowalewski, M. G.; Janz, S. J.
2015-02-01
Methods of absolute radiometric calibration of backscatter ultraviolet (BUV) satellite instruments are compared as part of an effort to minimize pre-launch calibration uncertainties. An internally illuminated integrating sphere source has been used for the Shuttle Solar BUV, Total Ozone Mapping Spectrometer, Ozone Mapping Instrument, and Global Ozone Monitoring Experiment 2 using standardized procedures traceable to national standards. These sphere-based spectral responsivities agree to within the derived combined standard uncertainty of 1.87% relative to calibrations performed using an external diffuser illuminated by standard irradiance sources, the customary spectral radiance responsivity calibration method for BUV instruments. The combined standard uncertainty for these calibration techniques as implemented at the NASA Goddard Space Flight Center’s Radiometric Calibration and Development Laboratory is shown to less than 2% at 250 nm when using a single traceable calibration standard.
Montgomery, Katherine L; Vaughn, Michael G; Thompson, Sanna J; Howard, Matthew O
2013-11-01
Research on juvenile offenders has largely treated this population as a homogeneous group. However, recent findings suggest that this at-risk population may be considerably more heterogeneous than previously believed. This study compared mixture regression analyses with standard regression techniques in an effort to explain how known factors such as distress, trauma, and personality are associated with drug abuse among juvenile offenders. Researchers recruited 728 juvenile offenders from Missouri juvenile correctional facilities for participation in this study. Researchers investigated past-year substance use in relation to the following variables: demographic characteristics (gender, ethnicity, age, familial use of public assistance), antisocial behavior, and mental illness symptoms (psychopathic traits, psychiatric distress, and prior trauma). Results indicated that standard and mixed regression approaches identified significant variables related to past-year substance use among this population; however, the mixture regression methods provided greater specificity in results. Mixture regression analytic methods may help policy makers and practitioners better understand and intervene with the substance-related subgroups of juvenile offenders.
Establishment of analysis method for methane detection by gas chromatography
NASA Astrophysics Data System (ADS)
Liu, Xinyuan; Yang, Jie; Ye, Tianyi; Han, Zeyu
2018-02-01
The study focused on the establishment of analysis method for methane determination by gas chromatography. Methane was detected by hydrogen flame ionization detector, and the quantitative relationship was determined by working curve of y=2041.2x+2187 with correlation coefficient of 0.9979. The relative standard deviation of 2.60-6.33% and the recovery rate of 96.36%∼105.89% were obtained during the parallel determination of standard gas. This method was not quite suitable for biogas content analysis because methane content in biogas would be over the measurement range in this method.
Percy, Andrew J; Mohammed, Yassene; Yang, Juncong; Borchers, Christoph H
2015-12-01
An increasingly popular mass spectrometry-based quantitative approach for health-related research in the biomedical field involves the use of stable isotope-labeled standards (SIS) and multiple/selected reaction monitoring (MRM/SRM). To improve inter-laboratory precision and enable more widespread use of this 'absolute' quantitative technique in disease-biomarker assessment studies, methods must be standardized. Results/methodology: Using this MRM-with-SIS-peptide approach, we developed an automated method (encompassing sample preparation, processing and analysis) for quantifying 76 candidate protein markers (spanning >4 orders of magnitude in concentration) in neat human plasma. The assembled biomarker assessment kit - the 'BAK-76' - contains the essential materials (SIS mixes), methods (for acquisition and analysis), and tools (Qualis-SIS software) for performing biomarker discovery or verification studies in a rapid and standardized manner.
Huber, J; Hüsler, J; Dieppe, P; Günther, K P; Dreinhöfer, K; Judge, A
2016-03-01
To validate a new method to identify responders (relative effect per patient (REPP) >0.2) using the OMERACT-OARSI criteria as gold standard in a large multicentre sample. The REPP ([score before - after treatment]/score before treatment) was calculated for 845 patients of a large multicenter European cohort study for THR. The patients with a REPP >0.2 were defined as responders. The responder rate was compared to the gold standard (OMERACT-OARSI criteria) using receiver operator characteristic (ROC) curve analysis for sensitivity, specificity and percentage of appropriately classified patients. With the criterion REPP>0.2 85.4% of the patients were classified as responders, applying the OARSI-OMERACT criteria 85.7%. The new method had 98.8% sensitivity, 94.2% specificity and 98.1% of the patients were correctly classified compared to the gold standard. The external validation showed a high sensitivity and also specificity of a new criterion to identify a responder compared to the gold standard method. It is simple and has no uncertainties due to a single classification criterion. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.
Campbell, Rebecca; Pierce, Steven J; Sharma, Dhruv B; Shaw, Jessica; Feeney, Hannah; Nye, Jeffrey; Schelling, Kristin; Fehler-Cabral, Giannina
2017-01-01
A growing number of U.S. cities have large numbers of untested sexual assault kits (SAKs) in police property facilities. Testing older kits and maintaining current case work will be challenging for forensic laboratories, creating a need for more efficient testing methods. We evaluated selective degradation methods for DNA extraction using actual case work from a sample of previously unsubmitted SAKs in Detroit, Michigan. We randomly assigned 350 kits to either standard or selective degradation testing methods and then compared DNA testing rates and CODIS entry rates between the two groups. Continuation-ratio modeling showed no significant differences, indicating that the selective degradation method had no decrement in performance relative to customary methods. Follow-up equivalence tests indicated that CODIS entry rates for the two methods could differ by more than ±5%. Selective degradation methods required less personnel time for testing and scientific review than standard testing. © 2016 American Academy of Forensic Sciences.
Quantification of plasma myo-inositol using gas chromatography-mass spectrometry.
Guo, Jin; Shi, Yingfei; Xu, Chengbao; Zhong, Rugang; Zhang, Feng; Zhang, Ting; Niu, Bo; Wang, Jianhua
2016-09-01
Myo-inositol (MI) deficiency is associated with an increased risk for neural tube defects (NTDs), mental disorders and metabolic diseases. We developed a gas chromatography-mass spectrometry (GC-MS) method to detect MI in human plasma, which was accurate, relatively efficient and convenient for clinical application. An external standard method was used for determination of plasma MI. Samples were analyzed by GC-MS after derivatization. The stable-isotope labeled internal standard approach was used to validate the method's accuracy. Alpha fetal protein (AFP) was detected by chemiluminescence immunoassay. The method was validated by determining the linearity, sensitivity and recovery rate. There was a good agreement between the internal standard approach and the present method. The NTD-affected pregnancies showed lower plasma MI (P=0.024) and higher AFP levels (P=0.001) than control. Maternal MI level showed a better discrimination in spina bifida subgroup, while AFP level showed a better discrimination in anencephaly subgroup after stratification analysis. We developed a sensitive and reliable method for the detection of clinical plasma MI, which might be a marker for NTDs screening, and established fundamental knowledge for clinical diagnosis and prevention for the diseases related to disturbed MI metabolism. Copyright © 2016 Elsevier B.V. All rights reserved.
An ecological method to understand agricultural standardization in peach orchard ecosystems
Wan, Nian-Feng; Zhang, Ming-Yi; Jiang, Jie-Xian; Ji, Xiang-Yun; Hao-Zhang
2016-01-01
While the worldwide standardization of agricultural production has been advocated and recommended, relatively little research has focused on the ecological significance of such a shift. The ecological concerns stemming from the standardization of agricultural production may require new methodology. In this study, we concentrated on how ecological two-sidedness and ecological processes affect the standardization of agricultural production which was divided into three phrases (pre-, mid- and post-production), considering both the positive and negative effects of agricultural processes. We constructed evaluation indicator systems for the pre-, mid- and post-production phases and here we presented a Standardization of Green Production Index (SGPI) based on the Full Permutation Polygon Synthetic Indicator (FPPSI) method which we used to assess the superiority of three methods of standardized production for peaches. The values of SGPI for pre-, mid- and post-production were 0.121 (Level IV, “Excellent” standard), 0.379 (Level III, “Good” standard), and 0.769 × 10−2 (Level IV, “Excellent” standard), respectively. Here we aimed to explore the integrated application of ecological two-sidedness and ecological process in agricultural production. Our results are of use to decision-makers and ecologists focusing on eco-agriculture and those farmers who hope to implement standardized agricultural production practices. PMID:26899360
An ecological method to understand agricultural standardization in peach orchard ecosystems.
Wan, Nian-Feng; Zhang, Ming-Yi; Jiang, Jie-Xian; Ji, Xiang-Yun; Hao-Zhang
2016-02-22
While the worldwide standardization of agricultural production has been advocated and recommended, relatively little research has focused on the ecological significance of such a shift. The ecological concerns stemming from the standardization of agricultural production may require new methodology. In this study, we concentrated on how ecological two-sidedness and ecological processes affect the standardization of agricultural production which was divided into three phrases (pre-, mid- and post-production), considering both the positive and negative effects of agricultural processes. We constructed evaluation indicator systems for the pre-, mid- and post-production phases and here we presented a Standardization of Green Production Index (SGPI) based on the Full Permutation Polygon Synthetic Indicator (FPPSI) method which we used to assess the superiority of three methods of standardized production for peaches. The values of SGPI for pre-, mid- and post-production were 0.121 (Level IV, "Excellent" standard), 0.379 (Level III, "Good" standard), and 0.769 × 10(-2) (Level IV, "Excellent" standard), respectively. Here we aimed to explore the integrated application of ecological two-sidedness and ecological process in agricultural production. Our results are of use to decision-makers and ecologists focusing on eco-agriculture and those farmers who hope to implement standardized agricultural production practices.
Satou, Chiemi; Goto, Hirofumi; Yamazaki, Yuya; Saitou, Katsuyoshi; Matsumoto, Shoji; Takahashi, Ou; Miyazaki, Yosuke; Ikuta, Keiichi; Yajima, Yosuke
2017-06-01
Monoacylglycerol (MAG) and diacylglycerol (DAG) are minor components of edible fats and oils, and they relate to the quality of these foods. The AOCS official method Cd 11b-91 has been used to determine MAG and DAG contents in fats and oils. There are, however, difficulties in the determination of MAG and DAG using this analytical procedure. Therefore, we improved this method by modifying the trimethylsilyl derivatization procedure and replacing the internal standard (IS) material. In our modified method, TMS-HT (mixture of hexamethyldisilazane and trimethylchlorosilane) was used for derivatization of MAG and DAG, which was followed by liquid-liquid extraction with water and n-hexane solution containing the IS, tricaprin. Using the modified method, we demonstrated superior repeatability in comparison with that of the AOCS method by reducing procedural difficulties. The relative standard deviation of distearin peak areas was 1.8% or 2.9% in the modified method, while it was 5.6% in the AOCS method. In addition, capillary columns, such as DB-1ht and DB-5ht could be used in this method.
41 CFR 60-741.21 - Prohibitions.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 41 Public Contracts and Property Management 1 2013-07-01 2013-07-01 false Prohibitions. 60-741.21 Section 60-741.21 Public Contracts and Property Management Other Provisions Relating to Public Contracts...) Standards, criteria or methods of administration. It is unlawful for the contractor to use standards...
41 CFR 60-741.21 - Prohibitions.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 41 Public Contracts and Property Management 1 2012-07-01 2009-07-01 true Prohibitions. 60-741.21 Section 60-741.21 Public Contracts and Property Management Other Provisions Relating to Public Contracts...) Standards, criteria or methods of administration. It is unlawful for the contractor to use standards...
77 FR 73345 - Safety Standard for Bedside Sleepers
Federal Register 2010, 2011, 2012, 2013, 2014
2012-12-10
... product-related issues, such as non- levelness of the product (two reports), instability of leg extensions...) Segmented Mattress Flatness Requirement and Test Method; (2) Removable Bassinet Bed Stability; and (3) Stability Test Dummy. Because bedside sleepers are already required to be tested to the bassinet standard...
Yang, Ting-Wen; Zhao, Chao; Fan, Yong; Qi, Lian-Wen; Li, Ping
2015-10-10
Single standard to determine multi-components (SSDMC) is a practical pattern for quality evaluation of herbal medicines (HMs). However, it remains challenging because of potential inconsistency of relative response factors (RRF) on different instruments. In this work, the effects of two key roles, i.e., ultraviolet (UV) wavelength and standard solution concentrations, on reproducibility of RRF were investigated. The effect of UV wavelength on reproducibility of RRF was studied by plotting the relationship of the peak area ratios (internal standard vs analyte) to wavelengths. The preferable wavelength should be set at the flat parts of the curve. Optimized 300 nm produced a 0.38% RSD for emodin/emodin-8-O-β-D-glucopyranoside on five instruments, much lower than 2.80% obtained from the maximum wavelength at 290 nm. Next, the effects of standard solution concentrations of emodin on its response factor (RF) were investigated. For one single point method, low concentration less than 49 b/k resulted in significant variations in RF. For emodin, when the concentration is higher than 7.00 μg mL(-1), a low standard deviation (SD) value at 0.13 was obtained, while lower than 7.00 μg mL(-1), a high SD at 3.71 was obtained. The developed SSDMC method was then applied to determination of target components in 10 Polygonum cuspidatum samples and showed comparable accuracy to conventional calibration methods with deviation less than 1%. Copyright © 2015 Elsevier B.V. All rights reserved.
Yehia, Ali M
2013-05-15
New, simple, specific, accurate and precise spectrophotometric technique utilizing ratio spectra is developed for simultaneous determination of two different binary mixtures. The developed ratio H-point standard addition method (RHPSAM) was managed successfully to resolve the spectral overlap in itopride hydrochloride (ITO) and pantoprazole sodium (PAN) binary mixture, as well as, mosapride citrate (MOS) and PAN binary mixture. The theoretical background and advantages of the newly proposed method are presented. The calibration curves are linear over the concentration range of 5-60 μg/mL, 5-40 μg/mL and 4-24 μg/mL for ITO, MOS and PAN, respectively. Specificity of the method was investigated and relative standard deviations were less than 1.5. The accuracy, precision and repeatability were also investigated for the proposed method according to ICH guidelines. Copyright © 2013 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Yehia, Ali M.
2013-05-01
New, simple, specific, accurate and precise spectrophotometric technique utilizing ratio spectra is developed for simultaneous determination of two different binary mixtures. The developed ratio H-point standard addition method (RHPSAM) was managed successfully to resolve the spectral overlap in itopride hydrochloride (ITO) and pantoprazole sodium (PAN) binary mixture, as well as, mosapride citrate (MOS) and PAN binary mixture. The theoretical background and advantages of the newly proposed method are presented. The calibration curves are linear over the concentration range of 5-60 μg/mL, 5-40 μg/mL and 4-24 μg/mL for ITO, MOS and PAN, respectively. Specificity of the method was investigated and relative standard deviations were less than 1.5. The accuracy, precision and repeatability were also investigated for the proposed method according to ICH guidelines.
Application of a dye-binding method for the determination of available lysine in skim milk powders.
Aalaei, Kataneh; Rayner, Marilyn; Tareke, Eden; Sjöholm, Ingegerd
2016-04-01
A dye-binding method using Acid Orange 12 was investigated regarding its suitability for the quantification of available lysine, as a means of monitoring the Maillard reaction in skim milk powders. The method was evaluated by analyzing a wide range of milk powders produced by three different drying methods and stored under various conditions. A pilot-scale freeze-dryer, spray-dryer and drum-dryer were used to produce skim milk powders and the samples were stored at two temperatures (20 °C and 30 °C) and two relative humidities (33% and 52%) under strictly controlled conditions. Moreover to validate the method, two protein isolates; bovine serum albumin and casein were investigated for their available lysine content. The results demonstrate the suitability of this method for measuring the available lysine in skim milk powders with good precision and high reproducibility. The relative standard deviations obtained from the 125 freeze-dried powders were 1.8%, and those from the 100 drum-dried samples were all 1.9%. The highest variation was found for the spray-dried powders, which showed relative standard deviations between 0.9% and 6.7%. Copyright © 2015 Elsevier Ltd. All rights reserved.
Monotonically improving approximate answers to relational algebra queries
NASA Technical Reports Server (NTRS)
Smith, Kenneth P.; Liu, J. W. S.
1989-01-01
We present here a query processing method that produces approximate answers to queries posed in standard relational algebra. This method is monotone in the sense that the accuracy of the approximate result improves with the amount of time spent producing the result. This strategy enables us to trade the time to produce the result for the accuracy of the result. An approximate relational model that characterizes appromimate relations and a partial order for comparing them is developed. Relational operators which operate on and return approximate relations are defined.
Field, Christopher R.; Lubrano, Adam; Woytowitz, Morgan; Giordano, Braden C.; Rose-Pehrsson, Susan L.
2014-01-01
The direct liquid deposition of solution standards onto sorbent-filled thermal desorption tubes is used for the quantitative analysis of trace explosive vapor samples. The direct liquid deposition method yields a higher fidelity between the analysis of vapor samples and the analysis of solution standards than using separate injection methods for vapors and solutions, i.e., samples collected on vapor collection tubes and standards prepared in solution vials. Additionally, the method can account for instrumentation losses, which makes it ideal for minimizing variability and quantitative trace chemical detection. Gas chromatography with an electron capture detector is an instrumentation configuration sensitive to nitro-energetics, such as TNT and RDX, due to their relatively high electron affinity. However, vapor quantitation of these compounds is difficult without viable vapor standards. Thus, we eliminate the requirement for vapor standards by combining the sensitivity of the instrumentation with a direct liquid deposition protocol to analyze trace explosive vapor samples. PMID:25145416
Field, Christopher R; Lubrano, Adam; Woytowitz, Morgan; Giordano, Braden C; Rose-Pehrsson, Susan L
2014-07-25
The direct liquid deposition of solution standards onto sorbent-filled thermal desorption tubes is used for the quantitative analysis of trace explosive vapor samples. The direct liquid deposition method yields a higher fidelity between the analysis of vapor samples and the analysis of solution standards than using separate injection methods for vapors and solutions, i.e., samples collected on vapor collection tubes and standards prepared in solution vials. Additionally, the method can account for instrumentation losses, which makes it ideal for minimizing variability and quantitative trace chemical detection. Gas chromatography with an electron capture detector is an instrumentation configuration sensitive to nitro-energetics, such as TNT and RDX, due to their relatively high electron affinity. However, vapor quantitation of these compounds is difficult without viable vapor standards. Thus, we eliminate the requirement for vapor standards by combining the sensitivity of the instrumentation with a direct liquid deposition protocol to analyze trace explosive vapor samples.
NASA Astrophysics Data System (ADS)
Uchida, Takeyoshi; Kikuchi, Tsuneo
2013-07-01
Ultrasonic power is one of the key quantities closely related to the safety of medical ultrasonic equipment. An ultrasonic power standard is required for establishment of safety. Generally, an ultrasonic power standard below approximately 20 W is established by the radiation force balance (RFB) method as the most accurate measurement method. However, RFB is not suitable for high ultrasonic power because of thermal damage to the absorbing target. Consequently, an alternative method to RFB is required. We have been developing a measurement technique for high ultrasonic power by the calorimetric method. In this study, we examined the effect of heat generation of an ultrasound transducer on ultrasonic power measured by the calorimetric method. As a result, an excessively high ultrasonic power was measured owing to the effect of heat generation from internal loss in the transducer. A reference ultrasound transducer with low heat generation is required for a high ultrasonic power standard established by the calorimetric method.
Comparing interval estimates for small sample ordinal CFA models
Natesan, Prathiba
2015-01-01
Robust maximum likelihood (RML) and asymptotically generalized least squares (AGLS) methods have been recommended for fitting ordinal structural equation models. Studies show that some of these methods underestimate standard errors. However, these studies have not investigated the coverage and bias of interval estimates. An estimate with a reasonable standard error could still be severely biased. This can only be known by systematically investigating the interval estimates. The present study compares Bayesian, RML, and AGLS interval estimates of factor correlations in ordinal confirmatory factor analysis models (CFA) for small sample data. Six sample sizes, 3 factor correlations, and 2 factor score distributions (multivariate normal and multivariate mildly skewed) were studied. Two Bayesian prior specifications, informative and relatively less informative were studied. Undercoverage of confidence intervals and underestimation of standard errors was common in non-Bayesian methods. Underestimated standard errors may lead to inflated Type-I error rates. Non-Bayesian intervals were more positive biased than negatively biased, that is, most intervals that did not contain the true value were greater than the true value. Some non-Bayesian methods had non-converging and inadmissible solutions for small samples and non-normal data. Bayesian empirical standard error estimates for informative and relatively less informative priors were closer to the average standard errors of the estimates. The coverage of Bayesian credibility intervals was closer to what was expected with overcoverage in a few cases. Although some Bayesian credibility intervals were wider, they reflected the nature of statistical uncertainty that comes with the data (e.g., small sample). Bayesian point estimates were also more accurate than non-Bayesian estimates. The results illustrate the importance of analyzing coverage and bias of interval estimates, and how ignoring interval estimates can be misleading. Therefore, editors and policymakers should continue to emphasize the inclusion of interval estimates in research. PMID:26579002
Comparing interval estimates for small sample ordinal CFA models.
Natesan, Prathiba
2015-01-01
Robust maximum likelihood (RML) and asymptotically generalized least squares (AGLS) methods have been recommended for fitting ordinal structural equation models. Studies show that some of these methods underestimate standard errors. However, these studies have not investigated the coverage and bias of interval estimates. An estimate with a reasonable standard error could still be severely biased. This can only be known by systematically investigating the interval estimates. The present study compares Bayesian, RML, and AGLS interval estimates of factor correlations in ordinal confirmatory factor analysis models (CFA) for small sample data. Six sample sizes, 3 factor correlations, and 2 factor score distributions (multivariate normal and multivariate mildly skewed) were studied. Two Bayesian prior specifications, informative and relatively less informative were studied. Undercoverage of confidence intervals and underestimation of standard errors was common in non-Bayesian methods. Underestimated standard errors may lead to inflated Type-I error rates. Non-Bayesian intervals were more positive biased than negatively biased, that is, most intervals that did not contain the true value were greater than the true value. Some non-Bayesian methods had non-converging and inadmissible solutions for small samples and non-normal data. Bayesian empirical standard error estimates for informative and relatively less informative priors were closer to the average standard errors of the estimates. The coverage of Bayesian credibility intervals was closer to what was expected with overcoverage in a few cases. Although some Bayesian credibility intervals were wider, they reflected the nature of statistical uncertainty that comes with the data (e.g., small sample). Bayesian point estimates were also more accurate than non-Bayesian estimates. The results illustrate the importance of analyzing coverage and bias of interval estimates, and how ignoring interval estimates can be misleading. Therefore, editors and policymakers should continue to emphasize the inclusion of interval estimates in research.
Endo, Yasushi
2018-01-01
Edible fats and oils are among the basic components of the human diet, along with carbohydrates and proteins, and they are the source of high energy and essential fatty acids such as linoleic and linolenic acids. Edible fats and oils are used in for pan- and deep-frying, and in salad dressing, mayonnaise and processed foods such as chocolates and cream. The physical and chemical properties of edible fats and oils can affect the quality of oil foods and hence must be evaluated in detail. The physical characteristics of edible fats and oils include color, specific gravity, refractive index, melting point, congeal point, smoke point, flash point, fire point, and viscosity, while the chemical characteristics include acid value, saponification value, iodine value, fatty acid composition, trans isomers, triacylglycerol composition, unsaponifiable matters (sterols, tocopherols) and minor components (phospholipids, chlorophyll pigments, glycidyl fatty acid esters). Peroxide value, p-anisidine value, carbonyl value, polar compounds and polymerized triacylglycerols are indexes of the deterioration of edible fats and oils. This review describes the analytical methods to evaluate the quality of edible fats and oils, especially the Standard Methods for Analysis of Fats, Oils and Related Materials edited by Japan Oil Chemists' Society (the JOCS standard methods) and advanced methods.
Zhang, Nan; Zhou, Juan; Yu, Jinlai; Hua, Ziyu; Li, Yongxue; Wu, Jiangang
2018-05-30
Medical injection pump is a commonly used clinical equipment with high risk. Accurate detection of flow is an important aspect to ensure its reliable operation. In this paper, we carefully studied and analyzed the flow detection methods of three standards being used in medical injection pump detection in our country. The three standards were compared from the aspects of standard device, flow test point selection, length of test time and accuracy judgment. The advantages and disadvantages of these standards were analyzed and suggestions for improvement were put forward.
Workshop on standards in biomass for energy and chemicals: proceedings
DOE Office of Scientific and Technical Information (OSTI.GOV)
Milne, T.A.
1984-11-01
In the course of reviewing standards literature, visiting prominent laboratories and research groups, attending biomass meetings and corresponding widely, a whole set of standards needs was identified, the most prominent of which were: biomass standard reference materials, research materials and sample banks; special collections of microorganisms, clonal material, algae, etc.; standard methods of characterization of substrates and biomass fuels; standard tests and methods for the conversion and end-use of biomass; standard protocols for the description, harvesting, preparation, storage, and measurement of productivity of biomass materials in the energy context; glossaries of terms; development of special tests for assay of enzymaticmore » activity and related processes. There was also a recognition of the need for government, professional and industry support of concensus standards development and the dissemination of information on standards. Some 45 biomass researchers and managers met with key NBS staff to identify and prioritize standards needs. This was done through three working panels: the Panel on Standard Reference Materials (SRM's), Research Materials (RM's), and Sample Banks; the Panel on Production and Characterization; and the Panel on Tests and Methods for Conversion and End Use. This report gives a summary of the action items in standards development recommended unanimously by the workshop attendees. The proceedings of the workshop, and an appendix, contain an extensive written record of the findings of the workshop panelists and others regarding presently existing standards and standards issues and needs. Separate abstracts have been prepared for selected papers for inclusion in the Energy Database.« less
ERIC Educational Resources Information Center
Lewy, Colleen; Sells, C. Wayne; Gilhooly, Jennifer; McKelvey, Robert
2009-01-01
Objective: The authors aim to determine whether pediatric residents used DSM-IV criteria to diagnose major depressive disorder and how this related to residents' confidence in diagnosis and treatment skills before and after clinical training with depressed adolescents. Methods: Pediatric residents evaluated two different standardized patients…
Four Ways to Skin a Definite Integral
ERIC Educational Resources Information Center
Dence, Thomas; Dence, Joseph
2010-01-01
The integral of 1/(1 + x[superscript 2]) is standard in elementary calculus, but the related integral 1/(1 + x[superscript 4]) rarely appears. In this article we examine the latter integral, computing its value by four different methods; several that involve standard elementary calculus techniques, and several involving complex integration.
Garbarino, J.R.; Taylor, Howard E.
1996-01-01
An inductively coupled plasma-mass spectrometry method was developed for the determination of dissolved Al, As, B, Ba, Be, Cd, Co, Cr, Cu, Li, Mn, Mo, Ni, Pb, Sr, Tl, U, V, and Zn in natural waters. Detection limits are generally in the 50-100 picogram per milliliter (pg/mL) range, with the exception of As which is in the 1 microgram per liter (ug/L) range. Interferences associated with spectral overlap from concomitant isotopes or molecular ions and sample matrix composition have been identified. Procedures for interference correction and reduction related to isotope selection, instrumental operating conditions, and mathematical data processing techniques are described. Internal standards are used to minimize instrumental drift. The average analytical precision attainable for 5 times the detection limit is about 16 percent. The accuracy of the method was tested using a series of U.S. Geological Survey Standard Reference Water Standards (SWRS), National Research Council Canada Riverine Water Standard, and National Institute of Standards and Technology (NIST) Trace Elements in Water Standards. Average accuracies range from 90 to 110 percent of the published mean values.
Informatics and Standards for Nanomedicine Technology
Thomas, Dennis G.; Klaessig, Fred; Harper, Stacey L.; Fritts, Martin; Hoover, Mark D.; Gaheen, Sharon; Stokes, Todd H.; Reznik-Zellen, Rebecca; Freund, Elaine T.; Klemm, Juli D.; Paik, David S.; Baker, Nathan A.
2011-01-01
There are several issues to be addressed concerning the management and effective use of information (or data), generated from nanotechnology studies in biomedical research and medicine. These data are large in volume, diverse in content, and are beset with gaps and ambiguities in the description and characterization of nanomaterials. In this work, we have reviewed three areas of nanomedicine informatics: information resources; taxonomies, controlled vocabularies, and ontologies; and information standards. Informatics methods and standards in each of these areas are critical for enabling collaboration, data sharing, unambiguous representation and interpretation of data, semantic (meaningful) search and integration of data; and for ensuring data quality, reliability, and reproducibility. In particular, we have considered four types of information standards in this review, which are standard characterization protocols, common terminology standards, minimum information standards, and standard data communication (exchange) formats. Currently, due to gaps and ambiguities in the data, it is also difficult to apply computational methods and machine learning techniques to analyze, interpret and recognize patterns in data that are high dimensional in nature, and also to relate variations in nanomaterial properties to variations in their chemical composition, synthesis, characterization protocols, etc. Progress towards resolving the issues of information management in nanomedicine using informatics methods and standards discussed in this review will be essential to the rapidly growing field of nanomedicine informatics. PMID:21721140
Zhang, Shuai; Li, PeiPei; Yan, Zhongyong; Long, Ju; Zhang, Xiaojun
2017-03-01
An ultraperformance liquid chromatography-quadrupole time-of-flight high-resolution mass spectrometry method was developed and validated for the determination of nitrofurazone metabolites. Precolumn derivatization with 2,4-dinitrophenylhydrazine and p-dimethylaminobenzaldehyde as an internal standard was used successfully to determine the biomarker 5-nitro-2-furaldehyde. In negative electrospray ionization mode, the precise molecular weights of the derivatives were 320.0372 for the biomarker and 328.1060 for the internal standard (relative error 1.08 ppm). The matrix effect was evaluated and the analytical characteristics of the method and derivatization reaction conditions were validated. For comparison purposes, spiked samples were tested by both internal and external standard methods. The results show high precision can be obtained with p-dimethylaminobenzaldehyde as an internal standard for the identification and quantification of nitrofurazone metabolites in complex biological samples. Graphical Abstract A simplified preparation strategy for biological samples.
Acevedo-Fontánez, Adrianna I; Suárez, Erick; Torres Cintrón, Carlos R; Ortiz, Ana P
2018-04-11
The aim of the study was to estimate the magnitude of the association between HPV-related gynecological neoplasms and secondary anal cancer among women in Puerto Rico (PR). We identified 9,489 women who had been diagnosed with a primary cervical, vaginal, or vulvar tumor during 1987-2013. To describe the trends of invasive cervical, vulvar, vaginal, and anal cancer, the age-adjusted incidence rates were estimated using the direct method (2000 US as Standard Population). Standardized incidence ratios (observed/expected) were computed using the indirect method; expected cases were calculated using 2 methods based on age-specific rates of anal cancer in PR. The ratio of standardized incidence ratios of anal cancer was estimated using the Poisson regression model to estimate the magnitude of the association between HPV-gynecologic neoplasms and secondary anal cancer. A significant increase in the incidence trend for anal cancer was observed from 1987 to 2013 (annual percent change = 1.1, p < .05), whereas from 2004 to 2013, an increase was observed for cervical cancer incidence (annual percent change = 3.3, p < .05). The risk of secondary anal cancer among women with HPV-related gynecological cancers was approximately 3 times this risk among women with non-HPV-related gynecological cancers (relative risk = 3.27, 95% CI = 1.37 to 7.79). Anal cancer is increasing among women in PR. Women with gynecological HPV-related tumors are at higher risk of secondary anal cancer as compared with women from the general population and with those with non-HPV-related gynecological cancers. Appropriate anal cancer screening guidelines for high-risk populations are needed, including women with HPV-related gynecological malignancies and potentially other cancer survivors.
Inertial effects on mechanically braked Wingate power calculations.
Reiser, R F; Broker, J P; Peterson, M L
2000-09-01
The standard procedure for determining subject power output from a 30-s Wingate test on a mechanically braked (friction-loaded) ergometer includes only the braking resistance and flywheel velocity in the computations. However, the inertial effects associated with accelerating and decelerating the crank and flywheel also require energy and, therefore, represent a component of the subject's power output. The present study was designed to determine the effects of drive-system inertia on power output calculations. Twenty-eight male recreational cyclists completed Wingate tests on a Monark 324E mechanically braked ergometer (resistance: 8.5% body mass (BM), starting cadence: 60 rpm). Power outputs were then compared using both standard (without inertial contribution) and corrected methods (with inertial contribution) of calculating power output. Relative 5-s peak power and 30-s average power for the corrected method (14.8 +/- 1.2 W x kg(-1) BM; 9.9 +/- 0.7 W x kg(-1) BM) were 20.3% and 3.1% greater than that of the standard method (12.3 +/- 0.7 W x kg(-1) BM; 9.6 +/- 0.7 W x kg(-1) BM), respectively. Relative 5-s minimum power for the corrected method (6.8 +/- 0.7 W x kg(-1) BM) was 6.8% less than that of the standard method (7.3 +/- 0.8 W x kg(-1) BM). The combined differences in the peak power and minimum power produced a fatigue index for the corrected method (54 +/- 5%) that was 31.7% greater than that of the standard method (41 +/- 6%). All parameter differences were significant (P < 0.01). The inertial contribution to power output was dominated by the flywheel; however, the contribution from the crank was evident. These results indicate that the inertial components of the ergometer drive system influence the power output characteristics, requiring care when computing, interpreting, and comparing Wingate results, particularly among different ergometer designs and test protocols.
NASA Astrophysics Data System (ADS)
Dementjev, Aleksandr S.; Jovaisa, A.; Silko, Galina; Ciegis, Raimondas
2005-11-01
Based on the developed efficient numerical methods for calculating the propagation of light beams, the alternative methods for measuring the beam radius and propagation ratio proposed in the international standard ISO 11146 are analysed. The specific calculations of the alternative beam propagation ratios Mi2 performed for a number of test beams with a complicated spatial structure showed that the correlation coefficients ci used in the international standard do not establish the universal one-to-one relation between the alternative propagation ratios Mi2 and invariant propagation ratios Mσ2 found by the method of moments.
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
1969-07-01
The Fifth International Conference on Nondestructive Testing was held in Montreal, Canada, for the purpose of promoting international collaboration in all matters related to the development and use of nondestructive test methods. A total of 82 papers were selected for presentation. Session titles included: evaluation of material quality; ultrasonics - identification and measurements; thermal methods; testing of welds; visual aids in nondestructive testing; measurements of stress and elastic properties; magnetic and eddy-current methods; surface methods and neutron radiography; standardization - general; ultrasonics at elevated temperatures; applications; x-ray techniques; radiography; ultrasonic standardization; training and qualification; and, correlation of weld defects.
Perez, Christina R.; Bonar, Scott A.; Amberg, Jon J.; Ladell, Bridget; Rees, Christopher B.; Stewart, William T.; Gill, Curtis J.; Cantrell, Chris; Robinson, Anthony
2017-01-01
Recently, methods involving examination of environmental DNA (eDNA) have shown promise for characterizing fish species presence and distribution in waterbodies. We evaluated the use of eDNA for standard fish monitoring surveys in a large reservoir. Specifically, we compared the presence, relative abundance, biomass, and relative percent composition of Largemouth Bass Micropterus salmoides and Gizzard Shad Dorosoma cepedianum measured through eDNA methods and established American Fisheries Society standard sampling methods for Theodore Roosevelt Lake, Arizona. Catches at electrofishing and gillnetting sites were compared with eDNA water samples at sites, within spatial strata, and over the entire reservoir. Gizzard Shad were detected at a higher percentage of sites with eDNA methods than with boat electrofishing in both spring and fall. In contrast, spring and fall gillnetting detected Gizzard Shad at more sites than eDNA. Boat electrofishing and gillnetting detected Largemouth Bass at more sites than eDNA; the exception was fall gillnetting, for which the number of sites of Largemouth Bass detection was equal to that for eDNA. We observed no relationship between relative abundance and biomass of Largemouth Bass and Gizzard Shad measured by established methods and eDNA copies at individual sites or lake sections. Reservoirwide catch composition for Largemouth Bass and Gizzard Shad (numbers and total weight [g] of fish) as determined through a combination of gear types (boat electrofishing plus gillnetting) was similar to the proportion of total eDNA copies from each species in spring and fall field sampling. However, no similarity existed between proportions of fish caught via spring and fall boat electrofishing and the proportion of total eDNA copies from each species. Our study suggests that eDNA field sampling protocols, filtration, DNA extraction, primer design, and DNA sequencing methods need further refinement and testing before incorporation into standard fish sampling surveys.
Kwon, Deukwoo; Reis, Isildinha M
2015-08-12
When conducting a meta-analysis of a continuous outcome, estimated means and standard deviations from the selected studies are required in order to obtain an overall estimate of the mean effect and its confidence interval. If these quantities are not directly reported in the publications, they must be estimated from other reported summary statistics, such as the median, the minimum, the maximum, and quartiles. We propose a simulation-based estimation approach using the Approximate Bayesian Computation (ABC) technique for estimating mean and standard deviation based on various sets of summary statistics found in published studies. We conduct a simulation study to compare the proposed ABC method with the existing methods of Hozo et al. (2005), Bland (2015), and Wan et al. (2014). In the estimation of the standard deviation, our ABC method performs better than the other methods when data are generated from skewed or heavy-tailed distributions. The corresponding average relative error (ARE) approaches zero as sample size increases. In data generated from the normal distribution, our ABC performs well. However, the Wan et al. method is best for estimating standard deviation under normal distribution. In the estimation of the mean, our ABC method is best regardless of assumed distribution. ABC is a flexible method for estimating the study-specific mean and standard deviation for meta-analysis, especially with underlying skewed or heavy-tailed distributions. The ABC method can be applied using other reported summary statistics such as the posterior mean and 95 % credible interval when Bayesian analysis has been employed.
Analytical evaluation of current starch methods used in the international sugar industry: Part I
USDA-ARS?s Scientific Manuscript database
Several analytical starch methods currently exist in the international sugar industry that are used to prevent or mitigate starch-related processing challenges as well as assess the quality of traded end-products. These methods use simple iodometric chemistry, mostly potato starch standards, and uti...
An isotope-dilution standard GC/MS/MS method for steroid hormones in water
Foreman, William T.; Gray, James L.; ReVello, Rhiannon C.; Lindley, Chris E.; Losche, Scott A.
2013-01-01
An isotope-dilution quantification method was developed for 20 natural and synthetic steroid hormones and additional compounds in filtered and unfiltered water. Deuterium- or carbon-13-labeled isotope-dilution standards (IDSs) are added to the water sample, which is passed through an octadecylsilyl solid-phase extraction (SPE) disk. Following extract cleanup using Florisil SPE, method compounds are converted to trimethylsilyl derivatives and analyzed by gas chromatography with tandem mass spectrometry. Validation matrices included reagent water, wastewater-affected surface water, and primary (no biological treatment) and secondary wastewater effluent. Overall method recovery for all analytes in these matrices averaged 100%; with overall relative standard deviation of 28%. Mean recoveries of the 20 individual analytes for spiked reagent-water samples prepared along with field samples analyzed in 2009–2010 ranged from 84–104%, with relative standard deviations of 6–36%. Detection levels estimated using ASTM International’s D6091–07 procedure range from 0.4 to 4 ng/L for 17 analytes. Higher censoring levels of 100 ng/L for bisphenol A and 200 ng/L for cholesterol and 3-beta-coprostanol are used to prevent bias and false positives associated with the presence of these analytes in blanks. Absolute method recoveries of the IDSs provide sample-specific performance information and guide data reporting. Careful selection of labeled compounds for use as IDSs is important because both inexact IDS-analyte matches and deuterium label loss affect an IDS’s ability to emulate analyte performance. Six IDS compounds initially tested and applied in this method exhibited deuterium loss and are not used in the final method.
Vo Duy, S; Besteiro, S; Berry, L; Perigaud, C; Bressolle, F; Vial, H J; Lefebvre-Tournier, I
2012-08-20
Plasmodium falciparum is the causative agent of malaria, a deadly infectious disease for which treatments are scarce and drug-resistant parasites are now increasingly found. A comprehensive method of identifying and quantifying metabolites of this intracellular parasite could expand the arsenal of tools to understand its biology, and be used to develop new treatments against the disease. Here, we present two methods based on liquid chromatography tandem mass spectrometry for reliable measurement of water-soluble metabolites involved in phospholipid biosynthesis, as well as several other metabolites that reflect the metabolic status of the parasite including amino acids, carboxylic acids, energy-related carbohydrates, and nucleotides. A total of 35 compounds was quantified. In the first method, polar compounds were retained by hydrophilic interaction chromatography (amino column) and detected in negative mode using succinic acid-(13)C(4) and fluorovaline as internal standards. In the second method, separations were carried out using reverse phase (C18) ion-pair liquid chromatography, with heptafluorobutyric acid as a volatile ion pairing reagent in positive detection mode, using d(9)-choline and 4-aminobutanol as internal standards. Standard curves were performed in P. falciparum-infected and uninfected red blood cells using standard addition method (r(2)>0.99). The intra- and inter-day accuracy and precision as well as the extraction recovery of each compound were determined. The lower limit of quantitation varied from 50pmol to 100fmol/3×10(7)cells. These methods were validated and successfully applied to determine intracellular concentrations of metabolites from uninfected host RBCs and isolated Plasmodium parasites. Copyright © 2012 Elsevier B.V. All rights reserved.
Analysis of street drugs in seized material without primary reference standards.
Laks, Suvi; Pelander, Anna; Vuori, Erkki; Ali-Tolppa, Elisa; Sippola, Erkki; Ojanperä, Ilkka
2004-12-15
A novel approach was used to analyze street drugs in seized material without primary reference standards. Identification was performed by liquid chromatography/time-of-flight mass spectrometry (LC/TOFMS), essentially based on accurate mass determination using a target library of 735 exact monoisotopic masses. Quantification was carried out by liquid chromatography/chemiluminescence nitrogen detection (LC/CLND) with a single secondary standard (caffeine), utilizing the detector's equimolar response to nitrogen. Sample preparation comprised dilution, first with methanol and further with the LC mobile phase. Altogether 21 seized drug samples were analyzed blind by the present method, and results were compared to accredited reference methods utilizing identification by gas chromatography/mass spectrometry and quantification by gas chromatography or liquid chromatography. The 31 drug findings by LC/TOFMS comprised 19 different drugs-of-abuse, byproducts, and adulterants, including amphetamine and tryptamine designer drugs, with one unresolved pair of compounds having an identical mass. By the reference methods, 27 findings could be confirmed, and among the four unconfirmed findings, only 1 apparent false positive was found. In the quantitative analysis of 11 amphetamine, heroin, and cocaine findings, mean relative difference between the results of LC/CLND and the reference methods was 11% (range 4.2-21%), without any observable bias. Mean relative standard deviation for three parallel LC/CLND results was 6%. Results suggest that the present combination of LC/TOFMS and LC/CLND offers a simple solution for the analysis of scheduled and designer drugs in seized material, independent of the availability of primary reference standards.
NASA Astrophysics Data System (ADS)
Pacheco-Sanchez, Anibal; Claus, Martin; Mothes, Sven; Schröter, Michael
2016-11-01
Three different methods for the extraction of the contact resistance based on both the well-known transfer length method (TLM) and two variants of the Y-function method have been applied to simulation and experimental data of short- and long-channel CNTFETs. While for TLM special CNT test structures are mandatory, standard electrical device characteristics are sufficient for the Y-function methods. The methods have been applied to CNTFETs with low and high channel resistance. It turned out that the standard Y-function method fails to deliver the correct contact resistance in case of a relatively high channel resistance compared to the contact resistances. A physics-based validation is also given for the application of these methods based on applying traditional Si MOSFET theory to quasi-ballistic CNTFETs.
Madej, Roberta M.; Davis, Jack; Holden, Marcia J.; Kwang, Stan; Labourier, Emmanuel; Schneider, George J.
2010-01-01
The utility of quantitative molecular diagnostics for patient management depends on the ability to relate patient results to prior results or to absolute values in clinical practice guidelines. To do this, those results need to be comparable across time and methods, either by producing the same value across methods and test versions or by using reliable and stable conversions. Universally available standards and reference materials specific to quantitative molecular technologies are critical to this process but are few in number. This review describes recent history in the establishment of international standards for nucleic acid test development, organizations involved in current efforts, and future issues and initiatives. PMID:20075208
Wang, Chao-Qun; Jia, Xiu-Hong; Zhu, Shu; Komatsu, Katsuko; Wang, Xuan; Cai, Shao-Qing
2015-03-01
A new quantitative analysis of multi-component with single marker (QAMS) method for 11 saponins (ginsenosides Rg1, Rb1, Rg2, Rh1, Rf, Re and Rd; notoginsenosides R1, R4, Fa and K) in notoginseng was established, when 6 of these saponins were individually used as internal referring substances to investigate the influences of chemical structure, concentrations of quantitative components, and purities of the standard substances on the accuracy of the QAMS method. The results showed that the concentration of the analyte in sample solution was the major influencing parameter, whereas the other parameters had minimal influence on the accuracy of the QAMS method. A new method for calculating the relative correction factors by linear regression was established (linear regression method), which demonstrated to decrease standard method differences of the QAMS method from 1.20%±0.02% - 23.29%±3.23% to 0.10%±0.09% - 8.84%±2.85% in comparison with the previous method. And the differences between external standard method and the QAMS method using relative correction factors calculated by linear regression method were below 5% in the quantitative determination of Rg1, Re, R1, Rd and Fa in 24 notoginseng samples and Rb1 in 21 notoginseng samples. And the differences were mostly below 10% in the quantitative determination of Rf, Rg2, R4 and N-K (the differences of these 4 constituents bigger because their contents lower) in all the 24 notoginseng samples. The results indicated that the contents assayed by the new QAMS method could be considered as accurate as those assayed by external standard method. In addition, a method for determining applicable concentration ranges of the quantitative components assayed by QAMS method was established for the first time, which could ensure its high accuracy and could be applied to QAMS methods of other TCMs. The present study demonstrated the practicability of the application of the QAMS method for the quantitative analysis of multi-component and the quality control of TCMs and TCM prescriptions. Copyright © 2014 Elsevier B.V. All rights reserved.
Integrated standardization concept for Angelica botanicals using quantitative NMR
Gödecke, Tanja; Yao, Ping; Napolitano, José G.; Nikolić, Dejan; Dietz, Birgit M.; Bolton, Judy L.; van Breemen, Richard B.; Farnsworth, Norman R.; Chen, Shao-Nong; Lankin, David C.; Pauli, Guido F.
2011-01-01
Despite numerous in vitro/vivo and phytochemical studies, the active constituents of Angelica sinensis (AS) have not been conclusively identified for the standardization to bioactive markers. Phytochemical analyses of AS extracts and fractions that demonstrate activity in a panel of in vitro bioassays, have repeatedly pointed to ligustilide as being (associated with) the active principle(s). Due to the chemical instability of ligustilide and related issues in GC/LC analyses, new methods capable of quantifying ligustilide in mixtures that do not rely on an identical reference standard are in high demand. This study demonstrates how NMR can satisfy the requirement for simultaneous, multi-target quantification and qualitative identification. First, the AS activity was concentrated into a single fraction by RP-solid-phase extraction, as confirmed by an (anti-)estrogenicity and cytotoxicity assay. Next, a quantitative 1H NMR (qHNMR) method was established and validated using standard compounds and comparing processing methods. Subsequent 1D/2D NMR and qHNMR analysis led to the identification and quantification of ligustilide and other minor components in the active fraction, and to the development of quality criteria for authentic AS preparations. The absolute and relative quantities of ligustilide, six minor alkyl phthalides, and groups of phenylpropanoids, polyynes, and poly-unsaturated fatty acids were measured by a combination of qHNMR and 2D COSY. The qNMR approach enables multi-target quality control of the bioactive fraction, and enables the integrated biological and chemical standardization of AS botanicals. This methodology can potentially be transferred to other botanicals with active principles that act synergistically, or that contain closely related and/or constituents, which have not been conclusively identified as the active principles. PMID:21907766
Kobayashi, Kazuhiro; Hama, Takanori; Murakami, Kasumi; Ogawa, Rei
2016-01-01
Objective: In this study, we evaluated the effect of scalp massage on hair in Japanese males and the effect of stretching forces on human dermal papilla cells in vitro. Methods: Nine healthy men received 4 minutes of standardized scalp massage per day for 24 weeks using a scalp massage device. Total hair number, hair thickness, and hair growth rate were evaluated. The mechanical effect of scalp massage on subcutaneous tissue was analyzed using a finite element method. To evaluate the effect of mechanical forces, human dermal papilla cells were cultured using a 72-hour stretching cycle. Gene expression change was analyzed using DNA microarray analyses. In addition, expression of hair cycle-related genes including IL6, NOGGIN, BMP4, and SMAD4 were evaluated using real-time reverse transcription-polymerase chain reaction. Results: Standardized scalp massage resulted in increased hair thickness 24 weeks after initiation of massage (0.085 ± 0.003 mm vs 0.092 ± 0.001 mm). Finite element method showed that scalp massage caused z-direction displacement and von Mises stress on subcutaneous tissue. In vitro, DNA microarray showed gene expression change significantly compared with nonstretching human dermal papilla cells. A total of 2655 genes were upregulated and 2823 genes were downregulated. Real-time reverse transcription-polymerase chain reaction demonstrated increased expression of hair cycle–related genes such as NOGGIN, BMP4, SMAD4, and IL6ST and decrease in hair loss–related genes such as IL6. Conclusions: Stretching forces result in changes in gene expression in human dermal papilla cells. Standardized scalp massage is a way to transmit mechanical stress to human dermal papilla cells in subcutaneous tissue. Hair thickness was shown to increase with standardized scalp massage. PMID:26904154
An improved method for bivariate meta-analysis when within-study correlations are unknown.
Hong, Chuan; D Riley, Richard; Chen, Yong
2018-03-01
Multivariate meta-analysis, which jointly analyzes multiple and possibly correlated outcomes in a single analysis, is becoming increasingly popular in recent years. An attractive feature of the multivariate meta-analysis is its ability to account for the dependence between multiple estimates from the same study. However, standard inference procedures for multivariate meta-analysis require the knowledge of within-study correlations, which are usually unavailable. This limits standard inference approaches in practice. Riley et al proposed a working model and an overall synthesis correlation parameter to account for the marginal correlation between outcomes, where the only data needed are those required for a separate univariate random-effects meta-analysis. As within-study correlations are not required, the Riley method is applicable to a wide variety of evidence synthesis situations. However, the standard variance estimator of the Riley method is not entirely correct under many important settings. As a consequence, the coverage of a function of pooled estimates may not reach the nominal level even when the number of studies in the multivariate meta-analysis is large. In this paper, we improve the Riley method by proposing a robust variance estimator, which is asymptotically correct even when the model is misspecified (ie, when the likelihood function is incorrect). Simulation studies of a bivariate meta-analysis, in a variety of settings, show a function of pooled estimates has improved performance when using the proposed robust variance estimator. In terms of individual pooled estimates themselves, the standard variance estimator and robust variance estimator give similar results to the original method, with appropriate coverage. The proposed robust variance estimator performs well when the number of studies is relatively large. Therefore, we recommend the use of the robust method for meta-analyses with a relatively large number of studies (eg, m≥50). When the sample size is relatively small, we recommend the use of the robust method under the working independence assumption. We illustrate the proposed method through 2 meta-analyses. Copyright © 2017 John Wiley & Sons, Ltd.
Hughes, Sarah A; Huang, Rongfu; Mahaffey, Ashley; Chelme-Ayala, Pamela; Klamerth, Nikolaus; Meshref, Mohamed N A; Ibrahim, Mohamed D; Brown, Christine; Peru, Kerry M; Headley, John V; Gamal El-Din, Mohamed
2017-11-01
There are several established methods for the determination of naphthenic acids (NAs) in waters associated with oil sands mining operations. Due to their highly complex nature, measured concentration and composition of NAs vary depending on the method used. This study compared different common sample preparation techniques, analytical instrument methods, and analytical standards to measure NAs in groundwater and process water samples collected from an active oil sands operation. In general, the high- and ultrahigh-resolution methods, namely high performance liquid chromatography time-of-flight mass spectrometry (UPLC-TOF-MS) and Orbitrap mass spectrometry (Orbitrap-MS), were within an order of magnitude of the Fourier transform infrared spectroscopy (FTIR) methods. The gas chromatography mass spectrometry (GC-MS) methods consistently had the highest NA concentrations and greatest standard error. Total NAs concentration was not statistically different between sample preparation of solid phase extraction and liquid-liquid extraction. Calibration standards influenced quantitation results. This work provided a comprehensive understanding of the inherent differences in the various techniques available to measure NAs and hence the potential differences in measured amounts of NAs in samples. Results from this study will contribute to the analytical method standardization for NA analysis in oil sands related water samples. Copyright © 2017 Elsevier Ltd. All rights reserved.
Vilaró, Francisca; Canela-Xandri, Anna; Canela, Ramon
2006-09-01
A specific, sensitive, precise, and accurate method for the determination of abscisic acid (ABA) in grapevine leaf tissues is described. The method employs high-performance liquid chromatography and electrospray ionization-mass spectrometry (LC-ESI-MS) in selected ion monitoring mode (SIM) to analyze ABA using a stable isotope-labeled ABA as an internal standard. Absolute recoveries ranged from 72% to 79% using methanol/water pH 5.5 (50:50 v/v) as an extraction solvent. The best efficiency was obtained when the chromatographic separation was carried out by using a porous graphitic carbon (PGC) column. The statistical evaluation of the method was satisfactory in the work range. A relative standard deviation (RDS) of < 5.5% and < 6.0% was obtained for intra-batch and inter-batch comparisons, respectively. As for accuracy, the relative error (%Er) was between -2.7 and 4.3%, and the relative recovery ranged from 95% to 107%.
The method of expected number of deaths, 1786-1886-1986.
Keiding, N
1987-04-01
"The method of expected number of deaths is an integral part of standardization of vital rates, which is one of the oldest statistical techniques. The expected number of deaths was calculated in 18th century actuarial mathematics...but the method seems to have been forgotten, and was reinvented in connection with 19th century studies of geographical and occupational variations of mortality.... It is noted that standardization of rates is intimately connected to the study of relative mortality, and a short description of very recent developments in the methodology of that area is included." (SUMMARY IN FRE) excerpt
ERIC Educational Resources Information Center
Hopwood, Christopher J.; Morey, Leslie C.; Edelen, Maria Orlando; Shea, M. Tracie; Grilo, Carlos M.; Sanislow, Charles A.; McGlashan, Thomas H.; Daversa, Maria T.; Gunderson, John G.; Zanarini, Mary C.; Markowitz, John C.; Skodol, Andrew E.
2008-01-01
Interview methods are widely regarded as the standard for the diagnosis of borderline personality disorder (BPD), whereas self-report methods are considered a time-efficient alternative. However, the relative validity of these methods has not been sufficiently tested. The current study used data from the Collaborative Longitudinal Personality…
Pan, Xinglu; Dong, Fengshou; Xu, Jun; Liu, Xingang; Chen, Zenglong; Liu, Na; Chen, Xixi; Tao, Yan; Zhang, Hongjun; Zheng, Yongquan
2015-05-01
A reliable and sensitive isotope-labelled internal standard method for simultaneous determination of chlorantraniliprole and cyantraniliprole in fruits (apple and grape), vegetables (cucumber and tomato) and cereals (rice and wheat) using ultra-high-performance liquid chromatography-tandem mass spectrometry was developed. Isotope-labelled internal standards were effective in compensating for the loss in the pretreatment and overcoming the matrix effect. The analytes were extracted with acetonitrile and cleaned up with different kinds of sorbents. The determination of the target compounds was achieved in less than 4 min using a T3 column combined with an electrospray ionization source in positive mode. The overall average relative recoveries in all matrices at three spiking levels (10, 20 and 50 μg kg(-1)) ranged from 95.5 to 106.2 %, with all relative standard deviations being less than 14.4 % for all analytes. The limits of detection did not exceed 0.085 μg kg(-1) and the limits of quantification were below 0.28 μg kg(-1) in all matrices. The method was demonstrated to be convenient and accurate for the routine monitoring of chlorantraniliprole and cyantraniliprole in fruits, vegetables and cereals.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Salvador Palau, A.; Eder, S. D., E-mail: sabrina.eder@uib.no; Kaltenbacher, T.
Time-of-flight (TOF) is a standard experimental technique for determining, among others, the speed ratio S (velocity spread) of a molecular beam. The speed ratio is a measure for the monochromaticity of the beam and an accurate determination of S is crucial for various applications, for example, for characterising chromatic aberrations in focussing experiments related to helium microscopy or for precise measurements of surface phonons and surface structures in molecular beam scattering experiments. For both of these applications, it is desirable to have as high a speed ratio as possible. Molecular beam TOF measurements are typically performed by chopping the beammore » using a rotating chopper with one or more slit openings. The TOF spectra are evaluated using a standard deconvolution method. However, for higher speed ratios, this method is very sensitive to errors related to the determination of the slit width and the beam diameter. The exact sensitivity depends on the beam diameter, the number of slits, the chopper radius, and the chopper rotation frequency. We present a modified method suitable for the evaluation of TOF measurements of high speed ratio beams. The modified method is based on a systematic variation of the chopper convolution parameters so that a set of independent measurements that can be fitted with an appropriate function are obtained. We show that with this modified method, it is possible to reduce the error by typically one order of magnitude compared to the standard method.« less
Faassen, Elisabeth J; Antoniou, Maria G; Beekman-Lukassen, Wendy; Blahova, Lucie; Chernova, Ekaterina; Christophoridis, Christophoros; Combes, Audrey; Edwards, Christine; Fastner, Jutta; Harmsen, Joop; Hiskia, Anastasia; Ilag, Leopold L; Kaloudis, Triantafyllos; Lopicic, Srdjan; Lürling, Miquel; Mazur-Marzec, Hanna; Meriluoto, Jussi; Porojan, Cristina; Viner-Mozzini, Yehudit; Zguna, Nadezda
2016-02-29
Exposure to β-N-methylamino-l-alanine (BMAA) might be linked to the incidence of amyotrophic lateral sclerosis, Alzheimer's disease and Parkinson's disease. Analytical chemistry plays a crucial role in determining human BMAA exposure and the associated health risk, but the performance of various analytical methods currently employed is rarely compared. A CYANOCOST initiated workshop was organized aimed at training scientists in BMAA analysis, creating mutual understanding and paving the way towards interlaboratory comparison exercises. During this workshop, we tested different methods (extraction followed by derivatization and liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS) analysis, or directly followed by LC-MS/MS analysis) for trueness and intermediate precision. We adapted three workup methods for the underivatized analysis of animal, brain and cyanobacterial samples. Based on recovery of the internal standard D₃BMAA, the underivatized methods were accurate (mean recovery 80%) and precise (mean relative standard deviation 10%), except for the cyanobacterium Leptolyngbya. However, total BMAA concentrations in the positive controls (cycad seeds) showed higher variation (relative standard deviation 21%-32%), implying that D₃BMAA was not a good indicator for the release of BMAA from bound forms. Significant losses occurred during workup for the derivatized method, resulting in low recovery (<10%). Most BMAA was found in a trichloroacetic acid soluble, bound form and we recommend including this fraction during analysis.
ERIC Educational Resources Information Center
Fulmer, Gavin W.; Polikoff, Morgan S.
2014-01-01
An essential component in school accountability efforts is for assessments to be well-aligned with the standards or curriculum they are intended to measure. However, relatively little prior research has explored methods to determine statistical significance of alignment or misalignment. This study explores analyses of alignment as a special case…
This standard operating procedure (SOP) describes a new, rapid, and relatively inexpensive way to remove a precise area of paint from the substrate of building structures in preparation for quantitative analysis. This method has been applied successfully in the laboratory, as we...
Cross-Validation of FITNESSGRAM® Health-Related Fitness Standards in Hungarian Youth
ERIC Educational Resources Information Center
Laurson, Kelly R.; Saint-Maurice, Pedro F.; Karsai, István; Csányi, Tamás
2015-01-01
Purpose: The purpose of this study was to cross-validate FITNESSGRAM® aerobic and body composition standards in a representative sample of Hungarian youth. Method: A nationally representative sample (N = 405) of Hungarian adolescents from the Hungarian National Youth Fitness Study (ages 12-18.9 years) participated in an aerobic capacity assessment…
ERIC Educational Resources Information Center
Wall, Denise E.; Least, Christine; Gromis, Judy; Lohse, Barbara
2012-01-01
Background: Impact of a classroom-based, standardized intervention to address limited vegetable consumption of fourth graders was assessed. Methods: A 4-lesson, vegetable-focused intervention, revised from extant materials was repurposed for Pennsylvania fourth graders with lessons aligned with state academic standards. A reliability-tested survey…
Rieger, M A; Lohmeyer, M; Nübling, M; Neuhaus, S; Diefenbach, H; Hofmann, F
2005-05-01
On the basis of EU directives 89/391/EEC (to encourage improvements in the safety and health of workers at work) and 2000/54/EC (on the protection of workers from risks related to exposure to biological agents at work), biological hazards at work have to be assessed and preventive measures have to be introduced in all member states of the EU. In Germany, national legislation (Biological Agents Ordinance - BioStoffV and Technical Rules on Biological Agents, TRBA) and recommendations of workers' compensation boards define standardized methods for the assessment of airborne mold, bacteria, and endotoxins. This article describes policies and practices in Germany for measurement of airborne bioaerosols and for interpretation of measurements relative to the standards. As an example, methods and results of measurements in agriculture are shown. The standardized measurement procedures proved suitable for use in livestock buildings. The results of the exploratory measurements in different livestock buildings confirmed the often high concentrations of airborne biological hazards in agriculture that are reported in the literature.
A thioacidolysis method tailored for higher‐throughput quantitative analysis of lignin monomers
Foster, Cliff; Happs, Renee M.; Doeppke, Crissa; Meunier, Kristoffer; Gehan, Jackson; Yue, Fengxia; Lu, Fachuang; Davis, Mark F.
2016-01-01
Abstract Thioacidolysis is a method used to measure the relative content of lignin monomers bound by β‐O‐4 linkages. Current thioacidolysis methods are low‐throughput as they require tedious steps for reaction product concentration prior to analysis using standard GC methods. A quantitative thioacidolysis method that is accessible with general laboratory equipment and uses a non‐chlorinated organic solvent and is tailored for higher‐throughput analysis is reported. The method utilizes lignin arylglycerol monomer standards for calibration, requires 1–2 mg of biomass per assay and has been quantified using fast‐GC techniques including a Low Thermal Mass Modular Accelerated Column Heater (LTM MACH). Cumbersome steps, including standard purification, sample concentrating and drying have been eliminated to help aid in consecutive day‐to‐day analyses needed to sustain a high sample throughput for large screening experiments without the loss of quantitation accuracy. The method reported in this manuscript has been quantitatively validated against a commonly used thioacidolysis method and across two different research sites with three common biomass varieties to represent hardwoods, softwoods, and grasses. PMID:27534715
A thioacidolysis method tailored for higher-throughput quantitative analysis of lignin monomers
DOE Office of Scientific and Technical Information (OSTI.GOV)
Harman-Ware, Anne E.; Foster, Cliff; Happs, Renee M.
Thioacidolysis is a method used to measure the relative content of lignin monomers bound by β-O-4 linkages. Current thioacidolysis methods are low-throughput as they require tedious steps for reaction product concentration prior to analysis using standard GC methods. A quantitative thioacidolysis method that is accessible with general laboratory equipment and uses a non-chlorinated organic solvent and is tailored for higher-throughput analysis is reported. The method utilizes lignin arylglycerol monomer standards for calibration, requires 1-2 mg of biomass per assay and has been quantified using fast-GC techniques including a Low Thermal Mass Modular Accelerated Column Heater (LTM MACH). Cumbersome steps, includingmore » standard purification, sample concentrating and drying have been eliminated to help aid in consecutive day-to-day analyses needed to sustain a high sample throughput for large screening experiments without the loss of quantitation accuracy. As a result, the method reported in this manuscript has been quantitatively validated against a commonly used thioacidolysis method and across two different research sites with three common biomass varieties to represent hardwoods, softwoods, and grasses.« less
A thioacidolysis method tailored for higher-throughput quantitative analysis of lignin monomers
Harman-Ware, Anne E.; Foster, Cliff; Happs, Renee M.; ...
2016-09-14
Thioacidolysis is a method used to measure the relative content of lignin monomers bound by β-O-4 linkages. Current thioacidolysis methods are low-throughput as they require tedious steps for reaction product concentration prior to analysis using standard GC methods. A quantitative thioacidolysis method that is accessible with general laboratory equipment and uses a non-chlorinated organic solvent and is tailored for higher-throughput analysis is reported. The method utilizes lignin arylglycerol monomer standards for calibration, requires 1-2 mg of biomass per assay and has been quantified using fast-GC techniques including a Low Thermal Mass Modular Accelerated Column Heater (LTM MACH). Cumbersome steps, includingmore » standard purification, sample concentrating and drying have been eliminated to help aid in consecutive day-to-day analyses needed to sustain a high sample throughput for large screening experiments without the loss of quantitation accuracy. As a result, the method reported in this manuscript has been quantitatively validated against a commonly used thioacidolysis method and across two different research sites with three common biomass varieties to represent hardwoods, softwoods, and grasses.« less
Phased-array vector velocity estimation using transverse oscillations.
Pihl, Michael J; Marcher, Jonne; Jensen, Jorgen A
2012-12-01
A method for estimating the 2-D vector velocity of blood using a phased-array transducer is presented. The approach is based on the transverse oscillation (TO) method. The purposes of this work are to expand the TO method to a phased-array geometry and to broaden the potential clinical applicability of the method. A phased-array transducer has a smaller footprint and a larger field of view than a linear array, and is therefore more suited for, e.g., cardiac imaging. The method relies on suitable TO fields, and a beamforming strategy employing diverging TO beams is proposed. The implementation of the TO method using a phased-array transducer for vector velocity estimation is evaluated through simulation and flow-rig measurements are acquired using an experimental scanner. The vast number of calculations needed to perform flow simulations makes the optimization of the TO fields a cumbersome process. Therefore, three performance metrics are proposed. They are calculated based on the complex TO spectrum of the combined TO fields. It is hypothesized that the performance metrics are related to the performance of the velocity estimates. The simulations show that the squared correlation values range from 0.79 to 0.92, indicating a correlation between the performance metrics of the TO spectrum and the velocity estimates. Because these performance metrics are much more readily computed, the TO fields can be optimized faster for improved velocity estimation of both simulations and measurements. For simulations of a parabolic flow at a depth of 10 cm, a relative (to the peak velocity) bias and standard deviation of 4% and 8%, respectively, are obtained. Overall, the simulations show that the TO method implemented on a phased-array transducer is robust with relative standard deviations around 10% in most cases. The flow-rig measurements show similar results. At a depth of 9.5 cm using 32 emissions per estimate, the relative standard deviation is 9% and the relative bias is -9%. At the center of the vessel, the velocity magnitude is estimated to be 0.25 ± 0.023 m/s, compared with an expected peak velocity magnitude of 0.25 m/s, and the beam-to-flow angle is calculated to be 89.3° ± 0.77°, compared with an expected angle value between 89° and 90°. For steering angles up to ±20° degrees, the relative standard deviation is less than 20%. The results also show that a 64-element transducer implementation is feasible, but with a poorer performance compared with a 128-element transducer. The simulation and experimental results demonstrate that the TO method is suitable for use in conjunction with a phased-array transducer, and that 2-D vector velocity estimation is possible down to a depth of 15 cm.
Hurst, William J; Stanley, Bruce; Glinski, Jan A; Davey, Matthew; Payne, Mark J; Stuart, David A
2009-10-15
This report describes the characterization of a series of commercially available procyanidin standards ranging from dimers DP = 2 to decamers DP = 10 for the determination of procyanidins from cocoa and chocolate. Using a combination of HPLC with fluorescence detection and MALDI-TOF mass spectrometry, the purity of each standard was determined and these data were used to determine relative response factors. These response factors were compared with other response factors obtained from published methods. Data comparing the procyanidin analysis of a commercially available US dark chocolate calculated using each of the calibration methods indicates divergent results and demonstrate that previous methods may significantly underreport the procyanidins in cocoa-containing products. These results have far reaching implications because the previous calibration methods have been used to develop data for a variety of scientific reports, including food databases and clinical studies.
Prigge, R.; Micke, H.; Krüger, J.
1963-01-01
As part of a collaborative assay of the proposed Fifth International Standard for Gas-Gangrene Antitoxin (Perfringens), five ampoules of the proposed replacement material were assayed in the authors' laboratory against the then current Fourth International Standard. Both in vitro and in vivo methods were used. This paper presents the results and their statistical analysis. The two methods yielded different results which were not likely to have been due to chance, but exact statistical comparison is not possible. It is thought, however, that the differences may be due, at least in part, to differences in the relative proportions of zeta-antitoxin and alpha-antitoxin in the Fourth and Fifth International Standards and the consequent different reactions with the test toxin that was used for titration. PMID:14107746
Meyer, Michael T.; Loftin, Keith A.; Lee, Edward A.; Hinshaw, Gary H.; Dietze, Julie E.; Scribner, Elisabeth A.
2009-01-01
The U.S. Geological Survey method (0-2141-09) presented is approved for the determination of glyphosate, its degradation product aminomethylphosphonic acid (AMPA), and glufosinate in water. It was was validated to demonstrate the method detection levels (MDL), compare isotope dilution to standard addition, and evaluate method and compound stability. The original method USGS analytical method 0-2136-01 was developed using liquid chromatography/mass spectrometry and quantitation by standard addition. Lower method detection levels and increased specificity were achieved in the modified method, 0-2141-09, by using liquid chromatography/tandem mass spectrometry (LC/MS/MS). The use of isotope dilution for glyphosate and AMPA and pseudo isotope dilution of glufosinate in place of standard addition was evaluated. Stable-isotope labeled AMPA and glyphosate were used as the isotope dilution standards. In addition, the stability of glyphosate and AMPA was studied in raw filtered and derivatized water samples. The stable-isotope labeled glyphosate and AMPA standards were added to each water sample and the samples then derivatized with 9-fluorenylmethylchloroformate. After derivatization, samples were concentrated using automated online solid-phase extraction (SPE) followed by elution in-line with the LC mobile phase; the compounds separated and then were analyzed by LC/MS/MS using electrospray ionization in negative-ion mode with multiple-reaction monitoring. The deprotonated derivatized parent molecule and two daughter-ion transition pairs were identified and optimized for glyphosate, AMPA, glufosinate, and the glyphosate and AMPA stable-isotope labeled internal standards. Quantitative comparison between standard addition and isotope dilution was conducted using 473 samples analyzed between April 2004 and June 2006. The mean percent difference and relative standard deviation between the two quantitation methods was 7.6 plus or minus 6.30 (n = 179), AMPA 9.6 plus or minus 8.35 (n = 206), and glufosinate 9.3 plus or minus 9.16 (n = 16). The analytical variation of the method, comparison of quantitation by isotope dilution and multipoint linear regressed standard curves, and method detection levels were evaluated by analyzing six sets of distilled-water, groundwater, and surface-water samples spiked in duplicate at 0.0, 0.05, 0.10 and 0.50 microgram per liter and analyzed on 6 different days during 1 month. The grand means of the normalized concentration percentage recovery for glyphosate, AMPA, and glufosinate among all three matrices and spiked concentrations ranged from 99 to 114 plus or minus 2 to 7 percent of the expected spiked concentration. The grand mean of the percentage difference between concentrations calculated by standard addition and linear regressed multipoint standard curves ranged from 8 to 15 plus or minus 2 to 9 percent for the three compounds. The method reporting levels calculated from all the 0.05- microgram per liter spiked samples were 0.02 microgram per liter for all three compounds. Compound stability experiments were conducted on 10 samples derivatized four times for periods between 136 to 269 days. The glyphosate and AMPA concentrations remained relatively constant in samples held up to 136 days before derivatization. The half life of glyphosate varied from 169 to 223 days in the underivatized samples. Derivatized samples were analyzed the day after derivitization, and again 54 and 64 days after derivatization. The derivatized samples analyzed at days 52 and 64 were within 20 percent of the concentrations of the derivatized samples analyzed the day after derivatization.
NASA Astrophysics Data System (ADS)
Wright, K. E.; Popa, K.; Pöml, P.
2018-01-01
Transmutation nuclear fuels contain weight percentage quantities of actinide elements, including Pu, Am and Np. Because of the complex spectra presented by actinide elements using electron probe microanalysis (EPMA), it is necessary to have relatively pure actinide element standards to facilitate overlap correction and accurate quantitation. Synthesis of actinide oxide standards is complicated by their multiple oxidation states, which can result in inhomogeneous standards or standards that are not stable at atmospheric conditions. Synthesis of PuP4 results in a specimen that exhibits stable oxidation-reduction chemistry and is sufficiently homogenous to serve as an EPMA standard. This approach shows promise as a method for producing viable actinide standards for microanalysis.
Data-optimized source modeling with the Backwards Liouville Test–Kinetic method
Woodroffe, J. R.; Brito, T. V.; Jordanova, V. K.; ...
2017-09-14
In the standard practice of neutron multiplicity counting , the first three sampled factorial moments of the event triggered neutron count distribution were used to quantify the three main neutron source terms: the spontaneous fissile material effective mass, the relative (α,n) production and the induced fission source responsible for multiplication. Our study compares three methods to quantify the statistical uncertainty of the estimated mass: the bootstrap method, propagation of variance through moments, and statistical analysis of cycle data method. Each of the three methods was implemented on a set of four different NMC measurements, held at the JRC-laboratory in Ispra,more » Italy, sampling four different Pu samples in a standard Plutonium Scrap Multiplicity Counter (PSMC) well counter.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Woodroffe, J. R.; Brito, T. V.; Jordanova, V. K.
In the standard practice of neutron multiplicity counting , the first three sampled factorial moments of the event triggered neutron count distribution were used to quantify the three main neutron source terms: the spontaneous fissile material effective mass, the relative (α,n) production and the induced fission source responsible for multiplication. Our study compares three methods to quantify the statistical uncertainty of the estimated mass: the bootstrap method, propagation of variance through moments, and statistical analysis of cycle data method. Each of the three methods was implemented on a set of four different NMC measurements, held at the JRC-laboratory in Ispra,more » Italy, sampling four different Pu samples in a standard Plutonium Scrap Multiplicity Counter (PSMC) well counter.« less
Reboulet, James; Cunningham, Robert; Gunasekar, Palur G; Chapman, Gail D; Stevens, Sean C
2009-02-01
A whole body inhalation study of mixed jet fuel vapor and its aerosol necessitated the development of a method for preparing vapor only standards from the neat fuel. Jet fuel is a complex mixture of components which partitions between aerosol and vapor when aspirated based on relative volatility of the individual compounds. A method was desired which could separate the vapor portion from the aerosol component to prepare standards for the calibration of infrared spectrophotometers and a head space gas chromatography system. A re-circulating loop system was developed which provided vapor only standards whose composition matched those seen in an exposure system. Comparisons of nominal concentrations in the exposure system to those determined by infrared spectrophotometry were in 92-95% agreement. Comparison of jet fuel vapor concentrations determined by infrared spectrophotometry compared to head space gas chromatography yielded a 93% overall agreement in trial runs. These levels of agreement show the loop system to be a viable method for creating jet fuel vapor standards for calibrating instruments.
Napolitano, José G.; Gödecke, Tanja; Lankin, David C.; Jaki, Birgit U.; McAlpine, James B.; Chen, Shao-Nong; Pauli, Guido F.
2013-01-01
The development of analytical methods for parallel characterization of multiple phytoconstituents is essential to advance the quality control of herbal products. While chemical standardization is commonly carried out by targeted analysis using gas or liquid chromatography-based methods, more universal approaches based on quantitative 1H NMR (qHNMR) measurements are being used increasingly in the multi-targeted assessment of these complex mixtures. The present study describes the development of a 1D qHNMR-based method for simultaneous identification and quantification of green tea constituents. This approach utilizes computer-assisted 1H iterative Full Spin Analysis (HiFSA) and enables rapid profiling of seven catechins in commercial green tea extracts. The qHNMR results were cross-validated against quantitative profiles obtained with an orthogonal LC-MS/MS method. The relative strengths and weaknesses of both approaches are discussed, with special emphasis on the role of identical reference standards in qualitative and quantitative analyses. PMID:23870106
McLain, B.J.
1993-01-01
Graphite furnace atomic absorption spectrophotometry is a sensitive, precise, and accurate method for the determination of chromium in natural water samples. The detection limit for this analytical method is 0.4 microg/L with a working linear limit of 25.0 microg/L. The precision at the detection limit ranges from 20 to 57 percent relative standard deviation (RSD) with an improvement to 4.6 percent RSD for concentrations more than 3 microg/L. Accuracy of this method was determined for a variety of reference standards that was representative of the analytical range. The results were within the established standard deviations. Samples were spiked with known concentrations of chromium with recoveries ranging from 84 to 122 percent. In addition, a comparison of data between graphite furnace atomic absorption spectrophotometry and direct-current plasma atomic emission spectrometry resulted in suitable agreement between the two methods, with an average deviation of +/- 2.0 microg/L throughout the analytical range.
Verification of spectrophotometric method for nitrate analysis in water samples
NASA Astrophysics Data System (ADS)
Kurniawati, Puji; Gusrianti, Reny; Dwisiwi, Bledug Bernanti; Purbaningtias, Tri Esti; Wiyantoko, Bayu
2017-12-01
The aim of this research was to verify the spectrophotometric method to analyze nitrate in water samples using APHA 2012 Section 4500 NO3-B method. The verification parameters used were: linearity, method detection limit, level of quantitation, level of linearity, accuracy and precision. Linearity was obtained by using 0 to 50 mg/L nitrate standard solution and the correlation coefficient of standard calibration linear regression equation was 0.9981. The method detection limit (MDL) was defined as 0,1294 mg/L and limit of quantitation (LOQ) was 0,4117 mg/L. The result of a level of linearity (LOL) was 50 mg/L and nitrate concentration 10 to 50 mg/L was linear with a level of confidence was 99%. The accuracy was determined through recovery value was 109.1907%. The precision value was observed using % relative standard deviation (%RSD) from repeatability and its result was 1.0886%. The tested performance criteria showed that the methodology was verified under the laboratory conditions.
ERIC Educational Resources Information Center
Fish, Laurel J.; Halcoussis, Dennis; Phillips, G. Michael
2017-01-01
The Monte Carlo method and related multiple imputation methods are traditionally used in math, physics and science to estimate and analyze data and are now becoming standard tools in analyzing business and financial problems. However, few sources explain the application of the Monte Carlo method for individuals and business professionals who are…
Comparing generalized ensemble methods for sampling of systems with many degrees of freedom
Lincoff, James; Sasmal, Sukanya; Head-Gordon, Teresa
2016-11-03
Here, we compare two standard replica exchange methods using temperature and dielectric constant as the scaling variables for independent replicas against two new corresponding enhanced sampling methods based on non-equilibrium statistical cooling (temperature) or descreening (dielectric). We test the four methods on a rough 1D potential as well as for alanine dipeptide in water, for which their relatively small phase space allows for the ability to define quantitative convergence metrics. We show that both dielectric methods are inferior to the temperature enhanced sampling methods, and in turn show that temperature cool walking (TCW) systematically outperforms the standard temperature replica exchangemore » (TREx) method. We extend our comparisons of the TCW and TREx methods to the 5 residue met-enkephalin peptide, in which we evaluate the Kullback-Leibler divergence metric to show that the rate of convergence between two independent trajectories is faster for TCW compared to TREx. Finally we apply the temperature methods to the 42 residue amyloid-β peptide in which we find non-negligible differences in the disordered ensemble using TCW compared to the standard TREx. All four methods have been made available as software through the OpenMM Omnia software consortium.« less
Comparing generalized ensemble methods for sampling of systems with many degrees of freedom.
Lincoff, James; Sasmal, Sukanya; Head-Gordon, Teresa
2016-11-07
We compare two standard replica exchange methods using temperature and dielectric constant as the scaling variables for independent replicas against two new corresponding enhanced sampling methods based on non-equilibrium statistical cooling (temperature) or descreening (dielectric). We test the four methods on a rough 1D potential as well as for alanine dipeptide in water, for which their relatively small phase space allows for the ability to define quantitative convergence metrics. We show that both dielectric methods are inferior to the temperature enhanced sampling methods, and in turn show that temperature cool walking (TCW) systematically outperforms the standard temperature replica exchange (TREx) method. We extend our comparisons of the TCW and TREx methods to the 5 residue met-enkephalin peptide, in which we evaluate the Kullback-Leibler divergence metric to show that the rate of convergence between two independent trajectories is faster for TCW compared to TREx. Finally we apply the temperature methods to the 42 residue amyloid-β peptide in which we find non-negligible differences in the disordered ensemble using TCW compared to the standard TREx. All four methods have been made available as software through the OpenMM Omnia software consortium (http://www.omnia.md/).
Related Rates and the Speed of Light.
ERIC Educational Resources Information Center
Althoen, S. C.; Weidner, J. F.
1985-01-01
Standard calculus textbooks often include a related rates problem involving light cast onto a straight line by a revolving light source. Mathematical aspects to these problems (both in the solution and in the method by which that solution is obtained) are examined. (JN)
Animal models for percutaneous-device-related infections: a review.
Shao, Jinlong; Kolwijck, Eva; Jansen, John A; Yang, Fang; Walboomers, X Frank
2017-06-01
This review focuses on the construction of animal models for percutaneous-device-related infections, and specifically the role of inoculation of bacteria in such models. Infections around percutaneous devices, such as catheters, dental implants and limb prostheses, are a recurrent and persistent clinical problem. To promote the research on this clinical problem, the establishment of a reliable and validated animal model would be of keen interest. In this review, literature related to percutaneous devices was evaluated, and particular attention was paid to studies involving the use of bacteria. The design of percutaneous devices, susceptibility of various animal species, bacterial strains, amounts of bacteria, method of inoculation and methods for subsequent evaluation of the infection are discussed in detail. Given that an ideal animal model for study of percutaneous-device-related infection is still not existent, this article presents the basis for the construction of such a standardized animal model for percutaneous-device-related infection studies. The inoculation of bacteria is critical to obtain an animal model for standardized studies for percutaneous-device-related infections. Copyright © 2017. Published by Elsevier B.V.
Military Standard: Sanitary Standards for Butter (and Related Products) Plants
1980-06-05
systems. When pasteurization is intenoed or required, the HTST or UHT system shall be equipped with an approved timing pump or device, or recorder...for not less than 30 minuses; o6 pasteurized by HTST method at a minimum temperature of not less than 185 F (85 C) for not less than 15 seconds, or it
40 CFR 75.6 - Incorporation by reference.
Code of Federal Regulations, 2011 CFR
2011-07-01
..., phone: 610-832-9585, http://www.astm.org/DIGITAL_LIBRARY/index.shtml. (1) ASTM D129-00, Standard Test... Information Reference Unit of the U.S. EPA, 401 M St., SW., Washington, DC and at the Library (MD-35), U.S... D4052-96 (Reapproved 2002), Standard Test Method for Density and Relative Density of Liquids by Digital...
40 CFR 75.6 - Incorporation by reference.
Code of Federal Regulations, 2014 CFR
2014-07-01
..., phone: 610-832-9585, http://www.astm.org/DIGITAL_LIBRARY/index.shtml. (1) ASTM D129-00, Standard Test... Information Reference Unit of the U.S. EPA, 401 M St., SW., Washington, DC and at the Library (MD-35), U.S... D4052-96 (Reapproved 2002), Standard Test Method for Density and Relative Density of Liquids by Digital...
40 CFR 75.6 - Incorporation by reference.
Code of Federal Regulations, 2012 CFR
2012-07-01
..., phone: 610-832-9585, http://www.astm.org/DIGITAL_LIBRARY/index.shtml. (1) ASTM D129-00, Standard Test... Information Reference Unit of the U.S. EPA, 401 M St., SW., Washington, DC and at the Library (MD-35), U.S... D4052-96 (Reapproved 2002), Standard Test Method for Density and Relative Density of Liquids by Digital...
40 CFR 75.6 - Incorporation by reference.
Code of Federal Regulations, 2013 CFR
2013-07-01
..., phone: 610-832-9585, http://www.astm.org/DIGITAL_LIBRARY/index.shtml. (1) ASTM D129-00, Standard Test... Information Reference Unit of the U.S. EPA, 401 M St., SW., Washington, DC and at the Library (MD-35), U.S... D4052-96 (Reapproved 2002), Standard Test Method for Density and Relative Density of Liquids by Digital...
Hess, Glen W.
2002-01-01
Techniques for estimating monthly streamflow-duration characteristics at ungaged and partial-record sites in central Nevada have been updated. These techniques were developed using streamflow records at six continuous-record sites, basin physical and climatic characteristics, and concurrent streamflow measurements at four partial-record sites. Two methods, the basin-characteristic method and the concurrent-measurement method, were developed to provide estimating techniques for selected streamflow characteristics at ungaged and partial-record sites in central Nevada. In the first method, logarithmic-regression analyses were used to relate monthly mean streamflows (from all months and by month) from continuous-record gaging sites of various percent exceedence levels or monthly mean streamflows (by month) to selected basin physical and climatic variables at ungaged sites. Analyses indicate that the total drainage area and percent of drainage area at altitudes greater than 10,000 feet are the most significant variables. For the equations developed from all months of monthly mean streamflow, the coefficient of determination averaged 0.84 and the standard error of estimate of the relations for the ungaged sites averaged 72 percent. For the equations derived from monthly means by month, the coefficient of determination averaged 0.72 and the standard error of estimate of the relations averaged 78 percent. If standard errors are compared, the relations developed in this study appear generally to be less accurate than those developed in a previous study. However, the new relations are based on additional data and the slight increase in error may be due to the wider range of streamflow for a longer period of record, 1995-2000. In the second method, streamflow measurements at partial-record sites were correlated with concurrent streamflows at nearby gaged sites by the use of linear-regression techniques. Statistical measures of results using the second method typically indicated greater accuracy than for the first method. However, to make estimates for individual months, the concurrent-measurement method requires several years additional streamflow data at more partial-record sites. Thus, exceedence values for individual months are not yet available due to the low number of concurrent-streamflow-measurement data available. Reliability, limitations, and applications of both estimating methods are described herein.
Development of a standardized differential-reflective bioassay for microbial pathogens
NASA Astrophysics Data System (ADS)
Wilhelm, Jay; Auld, J. R. X.; Smith, James E.
2008-04-01
This research examines standardizing a method for the rapid/semi-automated identification of microbial contaminates. It introduces a method suited to test for food/water contamination, serology, urinalysis and saliva testing for any >1 micron sized molecule that can be effectively bound to an identifying marker with exclusivity. This optical biosensor method seeks to integrate the semi-manual distribution of a collected sample onto a "transparent" substrate array of binding sites that will then be applied to a standard optical data disk and run for analysis. The detection of most microbe species is possible in this platform because the relative scale is greater than the resolution of the standard-scale digital information on a standard CD or DVD. This paper explains the critical first stage in the advance of this detection concept. This work has concentrated on developing the necessary software component needed to perform highly sensitive small-scale recognition using the standard optical disk as a detection platform. Physical testing has made significant progress in demonstrating the ability to utilize a standard optical drive for the purposes of micro-scale detection through the exploitation of CIRC error correction. Testing has also shown a definable trend in the optimum scale and geometry of micro-arrayed attachment sites for the technology's concept to reach achievement.
Normalized Legal Drafting and the Query Method.
ERIC Educational Resources Information Center
Allen, Layman E.; Engholm, C. Rudy
1978-01-01
Normalized legal drafting, a mode of expressing ideas in legal documents so that the syntax that relates the constituent propositions is simplified and standardized, and the query method, a question-asking activity that teaches normalized drafting and provides practice, are examined. Some examples are presented. (JMD)
STANDARD OPERATING PROCEDURE FOR QUALITY ASSURANCE IN ANALYTICAL CHEMISTRY METHODS DEVELOPMENT
The Environmental Protection Agency's (EPA) Office of Research and Development (ORD) is engaged in the development, demonstration, and validation of new or newly adapted methods of analysis for environmentally related samples. Recognizing that a "one size fits all" approach to qu...
Gravimetric method for the determination of diclofenac in pharmaceutical preparations.
Tubino, Matthieu; De Souza, Rafael L
2005-01-01
A gravimetric method for the determination of diclofenac in pharmaceutical preparations was developed. Diclofenac is precipitated from aqueous solution with copper(II) acetate in pH 5.3 (acetic acid/acetate buffer). Sample aliquots had approximately the same quantity of the drug content in tablets (50 mg) or in ampules (75 mg). The observed standard deviation was about +/- 2 mg; therefore, the relative standard deviation (RSD) was approximately 4% for tablet and 3% for ampule preparations. The results were compared with those obtained with the liquid chromatography method recommended in the United States Pharmacopoeia using the statistical Student's t-test. Complete agreement was observed. It is possible to obtain more precise results using higher aliquots, for example 200 mg, in which case the RSD falls to 1%. This gravimetric method, contrary to what is expected for this kind of procedure, is relatively fast and simple to perform. The main advantage is the absolute character of the gravimetric analysis.
Kim, Ki-Hyun; Szulejko, Jan E.; Kim, Yong-Hyun; Lee, Min-Hee
2014-01-01
The relative performance figure of merits was investigated for the two most common analytical methods employed for carbonyl compounds (CC), for example, between high performance liquid chromatography (HPLC)-UV detector (with 2,4-dinitrophenylhydrazine (DNPH) derivatization) and thermal desorption (TD)-gas chromatography (GC)-mass spectrometry (MS) (without derivatization). To this end, the suitability of each method is assessed by computing the relative recovery (RR) between the gas- and liquid-phase standards containing a suite of CC such as formaldehyde (FA), acetaldehyde (AA), propionaldehyde (PA), butyraldehyde (BA), isovaleraldehyde (IA), and valeraldehyde (VA) along with benzene (B) as a recovery reference for the GC method. The results confirm that a TD-GC-MS is advantageous to attain the maximum recovery for the heavier CCs (i.e., with molecular weights (MW) above BA−MW ≥ 74). On the other hand, the HPLC-UV is favorable for the lighter CCs (like FA and AA) with the least bias. Such compound-specific responses for each platform are validated by relative ordering of CCs as a function of response factor (RF), method detection limit (MDL), and recovery pattern. It is thus desirable to understand the advantages and limitations of each method to attain the CC data with the least experimental bias. PMID:24719571
Study on Quality Standard of Processed Curcuma Longa Radix
Zhao, Yongfeng; Quan, Liang; Zhou, Haiting; Cao, Dong; Li, Wenbing; Yang, Zhuo
2017-01-01
To control the quality of Curcuma Longa Radix by establishing quality standards, this paper increased the contents of extract and volatile oil determination. Meanwhile, the curcumin was selected as the internal marker, and the relative correlation factors (RCFs) of demethoxycurcumin and bisdemethoxycurcumin were established by high performance liquid chromatography (HPLC). The contents of multicomponents were calculated based on their RCFs. The rationality and feasibility of the methods were evaluated by comparison of the quantitative results between external standard method (ESM) and quantitative analysis of multicomponents by single-marker (QAMS). Ethanol extracts ranged from 9.749 to 15.644% and the mean value was 13.473%. The volatile oil ranged from 0.45 to 0.90 mL/100 g and the mean value was 0.66 mL/100 g. This method was accurate and feasible and could provide a reference for further comprehensive and effective control of the quality standard of Curcuma Longa Radix and its processed products. PMID:29375640
Li, Minmin; Liu, Xingang; Dong, Fengshou; Xu, Jun; Qin, Dongmei; Zheng, Yongquan
2012-10-01
A new, highly sensitive, and selective method was developed for the determination of the cyflumetofen residue in water, soil, and fruits by using gas chromatography quadruple mass spectrometry. The target compound was extracted using acetonitrile and then cleaned up using dispersive solid-phase extraction with primary and secondary amine and graphitized carbon black, and optionally by a freezing-out cleanup step. The matrix-matched standards gave satisfactory recoveries and relative standard deviation values in different matrices at three fortified levels (0.05, 0.5, and 1.0 mg kg(-1) ). The overall average recoveries for this method in water, soil, and all fruits matrix at three fortified levels ranged from 76.3 to 101.5% with relative standard deviations in the range of 1.2-11.8% (n = 5). The calculated limits of detection and quantification were typically below 0.005 and 0.015 μg kg(-1), which were much lower than the maximum residue levels established by Japanese Positive List. This study provides a theoretical basis for China to draw up maximum residue level and analytical method for cyflumetofen acaricide in different fruits. © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Environmentally safe aviation fuels
NASA Technical Reports Server (NTRS)
Liberio, Patricia D.
1995-01-01
In response to the Air Force directive to remove Ozone Depleting Chemicals (ODC's) from military specifications and Defense Logistics Agency's Hazardous Waste Minimization Program, we are faced with how to ensure a quality aviation fuel without using such chemicals. Many of these chemicals are found throughout the fuel and fuel related military specifications and are part of test methods that help qualify the properties and quality of the fuels before they are procured. Many years ago there was a directive for military specifications to use commercially standard test methods in order to provide standard testing in private industry and government. As a result the test methods used in military specifications are governed by the American Society of Testing and Materials (ASTM). The Air Force has been very proactive in the removal or replacement of the ODC's and hazardous materials in these test methods. For example, ASTM D3703 (Standard Test Method for Peroxide Number of Aviation Turbine Fuels), requires the use of Freon 113, a known ODC. A new rapid, portable hydroperoxide test for jet fuels similar to ASTM D3703 that does not require the use of ODC's has been developed. This test has proved, in limited testing, to be a viable substitute method for ASTM D3703. The Air Force is currently conducting a round robin to allow the method to be accepted by ASTM and therefore replace the current method. This paper will describe the Air Force's initiatives to remove ODC's and hazardous materials from the fuel and fuel related military specifications that the Air Force Wright Laboratory.
International Comparison of Product Certification and Verification Methods for Appliances
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhou, Nan; Romankiewicz, John; Fridley, David
2012-06-01
Enforcement of appliance standards and consumer trust in appliance labeling are important foundations of growing a more energy efficient economy. Product certification and verification increase compliance rates which in turn increase both energy savings and consumer trust. This paper will serve two purposes: 1) to review international practices for product certification and verification as they relate to the enforcement of standards and labeling programs in the U.S., E.U., Australia, Japan, Canada, and China; and 2) to make recommendations for China to implement improved certification processes related to their mandatory standards and labeling program such as to increase compliance rates andmore » energy savings potential.« less
Botts, Nathan; Bouhaddou, Omar; Bennett, Jamie; Pan, Eric; Byrne, Colene; Mercincavage, Lauren; Olinger, Lois; Hunolt, Elaine; Cullen, Theresa
2014-01-01
Authors studied the United States (U.S.) Department of Veterans Affairs' (VA) Virtual Lifetime Electronic Record (VLER) Health pilot phase relative to two attributes of data quality - the adoption of eHealth Exchange data standards, and clinical content exchanged. The VLER Health pilot was an early effort in testing implementation of eHealth Exchange standards and technology. Testing included evaluation of exchange data from the VLER Health pilot sites partners: VA, U.S. Department of Defense (DoD), and private sector health care organizations. Domains assessed data quality and interoperability as it relates to: 1) conformance with data standards related to the underlying structure of C32 Summary Documents (C32) produced by eHealth Exchange partners; and 2) the types of C32 clinical content exchanged. This analysis identified several standards non-conformance issues in sample C32 files and informed further discourse on the methods needed to effectively monitor Health Information Exchange (HIE) data content and standards conformance.
Comparing the Methodologies in ASTM G198: Is There an Easy Way Out?
Samuel L. Zelinka
2013-01-01
ASTM(1) G198, Standard test method for determining the relative corrosion performance of driven fasteners in contact with treated wood, was accepted by consensus and published in 2011. The method has two different exposure conditions for determining fastener corrosion performance in treated wood. The first method places the wood and embedded...
The density-salinity relation of standard seawater
NASA Astrophysics Data System (ADS)
Schmidt, Hannes; Seitz, Steffen; Hassel, Egon; Wolf, Henning
2018-01-01
The determination of salinity by means of electrical conductivity relies on stable salt proportions in the North Atlantic Ocean, because standard seawater, which is required for salinometer calibration, is produced from water of the North Atlantic. To verify the long-term stability of the standard seawater composition, it was proposed to perform measurements of the standard seawater density. Since the density is sensitive to all salt components, a density measurement can detect any change in the composition. A conversion of the density values to salinity can be performed by means of a density-salinity relation. To use such a relation with a target uncertainty in salinity comparable to that in salinity obtained from conductivity measurements, a density measurement with an uncertainty of 2 g m-3 is mandatory. We present a new density-salinity relation based on such accurate density measurements. The substitution measurement method used is described and density corrections for uniform isotopic and chemical compositions are reported. The comparison of densities calculated using the new relation with those calculated using the present reference equations of state TEOS-10 suggests that the density accuracy of TEOS-10 (as well as that of EOS-80) has been overestimated, as the accuracy of some of its underlying density measurements had been overestimated. The new density-salinity relation may be used to verify the stable composition of standard seawater by means of routine density measurements.
[ELEMENTS OF A SYSTEMATIC APPROACH TO HYGIENIC REGULATION OF XENOBIOTICS].
Shtabskiy, B M; Gzhegotskiy, M R; Shafran, L M
2016-01-01
Hygienic standardization (HS) of chemicals remains to be the one of the effective ways to ensure chemical safety of the population. At that hygienic standards (such as maximum allowable concentrations--MACs) are interrelated and aggregated into the coherent systems. Therefore, the task of the study was in establishment of the logic of inter- standard relations between the existing standards and actualization of legitimate relations of the interrelations such as MACwz/MACatm, (i.e., to systematize standards) and so as CL₅₀/MACwz (reflecting the ratio of reliability). In the suggested systemic approach the benchmark indices of the proposed HS system are the values of the MACwz. Standards for other media, including atmosphere air may be only some compartments of MACwz. The performed studies and calculations allowed to justify and implement the system approach into the practice of HS in Ukraine. There is need for further search for additional solutions in nonreachability of LC₅₀ in the experiment, justification of standards for the population in the absence of MACwz, comparison with the data of normative databases of other countries. It is necessary to introduce the value of permissible deviation from the requirements of the systemness, to embody conditions (1)-(7) into the general principle of the prohibition of greater deviation and to harmonize acting and newly introduced standards within frameworks of modern ideology and methods of HS of harmful substances. This opens up broad prospects for the new phase of HS and a significant increase in the reliability of results obtained by the various methods and in different laboratories.
Faassen, Elisabeth J.; Antoniou, Maria G.; Beekman-Lukassen, Wendy; Blahova, Lucie; Chernova, Ekaterina; Christophoridis, Christophoros; Combes, Audrey; Edwards, Christine; Fastner, Jutta; Harmsen, Joop; Hiskia, Anastasia; Ilag, Leopold L.; Kaloudis, Triantafyllos; Lopicic, Srdjan; Lürling, Miquel; Mazur-Marzec, Hanna; Meriluoto, Jussi; Porojan, Cristina; Viner-Mozzini, Yehudit; Zguna, Nadezda
2016-01-01
Exposure to β-N-methylamino-l-alanine (BMAA) might be linked to the incidence of amyotrophic lateral sclerosis, Alzheimer’s disease and Parkinson’s disease. Analytical chemistry plays a crucial role in determining human BMAA exposure and the associated health risk, but the performance of various analytical methods currently employed is rarely compared. A CYANOCOST initiated workshop was organized aimed at training scientists in BMAA analysis, creating mutual understanding and paving the way towards interlaboratory comparison exercises. During this workshop, we tested different methods (extraction followed by derivatization and liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS) analysis, or directly followed by LC-MS/MS analysis) for trueness and intermediate precision. We adapted three workup methods for the underivatized analysis of animal, brain and cyanobacterial samples. Based on recovery of the internal standard D3BMAA, the underivatized methods were accurate (mean recovery 80%) and precise (mean relative standard deviation 10%), except for the cyanobacterium Leptolyngbya. However, total BMAA concentrations in the positive controls (cycad seeds) showed higher variation (relative standard deviation 21%–32%), implying that D3BMAA was not a good indicator for the release of BMAA from bound forms. Significant losses occurred during workup for the derivatized method, resulting in low recovery (<10%). Most BMAA was found in a trichloroacetic acid soluble, bound form and we recommend including this fraction during analysis. PMID:26938542
Zaugg, Steven D.; Smith, Steven G.; Schroeder, Michael P.
2006-01-01
A method for the determination of 69 compounds typically found in domestic and industrial wastewater is described. The method was developed in response to increasing concern over the impact of endocrine-disrupting chemicals on aquatic organisms in wastewater. This method also is useful for evaluating the effects of combined sanitary and storm-sewer overflow on the water quality of urban streams. The method focuses on the determination of compounds that are indicators of wastewater or have endocrine-disrupting potential. These compounds include the alkylphenol ethoxylate nonionic surfactants, food additives, fragrances, antioxidants, flame retardants, plasticizers, industrial solvents, disinfectants, fecal sterols, polycyclic aromatic hydrocarbons, and high-use domestic pesticides. Wastewater compounds in whole-water samples were extracted using continuous liquid-liquid extractors and methylene chloride solvent, and then determined by capillary-column gas chromatography/mass spectrometry. Recoveries in reagent-water samples fortified at 0.5 microgram per liter averaged 72 percent ? 8 percent relative standard deviation. The concentration of 21 compounds is always reported as estimated because method recovery was less than 60 percent, variability was greater than 25 percent relative standard deviation, or standard reference compounds were prepared from technical mixtures. Initial method detection limits averaged 0.18 microgram per liter. Samples were preserved by adding 60 grams of sodium chloride and stored at 4 degrees Celsius. The laboratory established a sample holding-time limit prior to sample extraction of 14 days from the date of collection.
7 CFR 277.14 - Procurement standards.
Code of Federal Regulations, 2010 CFR
2010-01-01
... qualitative nature of the material, product or service desired and, when necessary, shall set forth those... technical resources. (g) Procurement methods. State agency procurements made in whole or in part with program funds shall be by one of the following methods: (1) Small purchase procedures are those relatively...
Zhu, H B; Su, C J; Tang, H F; Ruan, Z; Liu, D H; Wang, H; Qian, Y L
2017-10-20
Objective: To establish a method for rapid determination of 47 volatile organic compounds in the air of workplace using portable gas chromatography - mass spectrometer(GC - MS). Methods: The mixed standard gas with different concentration levels was made by using the static gas distribution method with the high purity nitrogen as dilution gas. The samples were injected into the GC - MS by a hand - held probe. Retention time and characteristic ion were used for qualitative analysis,and the internal standard method was usd for quantitation. Results: The 47 poisonous substances were separated and determined well. The linear range of this method was 0.2 - 16.0 mg/m(3),and the relative standard deviation of 45 volatile ovganic compounds was 3.8% - 15.8%. The average recovery was 79.3% - 119.0%. Conclusion: The method is simple,accurate,sensitive,has good separation effect,short analysis period, can be used for qualitative and quantitative analysis of volatile organic compounds in the workplace, and also supports the rapid identification and detection of occupational hazards.
[Determination of 27 elements in Maca nationality's medicine by microwave digestion ICP-MS].
Yu, Gui-fang; Zhong, Hai-jie; Hu, Jun-hua; Wang, Jing; Huang, Wen-zhe; Wang, Zhen-zhong; Xiao, Wei
2015-12-01
An analysis method has been established to test 27 elements (Li, Be, B, Mg, Al, Sc, Ti, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, Ga, As, Sr, Mo, Cd, Sn, Sb, Ba, La, Hg, Pb, Bi) in Maca nationality's medicine with microwave digestion-ICP-MS. Sample solutions were analyzed by ICP-MS after microwave digestion, and the contents of elements were calculated according to their calibration curves, and internal standard method was adopted to reduce matrix effect and other interference effects. The experimental results showed that the linear relations of all the elements were very good; the correlation coefficient (r) was 0.9994-1.0000 (Hg was 0.9982) ; the limits of detection were 0.003-2.662 microg x L(-1); the relative standard deviations for all elements of reproducibility were lower than 5% (except the individual elements); the recovery rate were 78.5%-123.7% with RSD lower than 5% ( except the individual elements). The analytical results of standard material showed acceptable agreement with the certified values. This method was applicable to determinate the contents of multi-elements in Maca which had a high sensitivity, good specificity and good repeatability, and provide basis for the quality control of Maca.
[Expert investigation on food safety standard system framework construction in China].
He, Xiang; Yan, Weixing; Fan, Yongxiang; Zeng, Biao; Peng, Zhen; Sun, Zhenqiu
2013-09-01
Through investigating food safety standard framework among food safety experts, to summarize the basic elements and principles of food safety standard system, and provide policy advices for food safety standards framework. A survey was carried out among 415 experts from government, professional institutions and the food industry/enterprises using the National Food Safety Standard System Construction Consultation Questionnaire designed in the name of the Secretariat of National Food Safety Standard Committee. Experts have different advices in each group about the principles of food product standards, food additive product standards, food related product standards, hygienic practice, test methods. According to the results, the best solution not only may reflect experts awareness of the work of food safety standards situation, but also provide advices for setting and revision of food safety standards for the next. Through experts investigation, the framework and guiding principles of food safety standard had been built.
Stengel, Andreas; Keire, David; Goebel, Miriam; Evilevitch, Lena; Wiggins, Brian; Taché, Yvette; Reeve, Joseph R
2009-11-01
The correct identification of circulating molecular forms and measurement of peptide levels in blood entails that the endocrine peptide being studied is stable and recovered in good yields during blood processing. However, it is not clear whether this is achieved in studies using standard blood processing. Therefore, we compared peptide concentration and form of 12 (125)I-labeled peptides using the standard procedure (EDTA-blood on ice) and a new method employing Reduced temperatures, Acidification, Protease inhibition, Isotopic exogenous controls, and Dilution (RAPID). During standard processing there was at least 80% loss for calcitonin-gene-related peptide and cholecystokinin-58 (CCK-58) and more than 35% loss for amylin, insulin, peptide YY forms (PYY((1-36)) and PYY((3-36))), and somatostatin-28. In contrast, the RAPID method significantly improved the recovery for 11 of 12 peptides (P < 0.05) and eliminated the breakdown of endocrine peptides occurring after standard processing as reflected in radically changed molecular forms for CCK-58, gastrin-releasing peptide, somatostatin-28, and ghrelin. For endogenous ghrelin, this led to an acyl/total ghrelin ratio of 1:5 instead of 1:19 by the standard method. These results show that the RAPID method enables accurate assessment of circulating gut peptide concentrations and forms such as CCK-58, acylated ghrelin, and somatostatin-28. Therefore, the RAPID method represents an efficacious means to detect circulating variations in peptide concentrations and form relevant to the understanding of physiological function of endocrine peptides.
Hancewicz, Thomas M; Xiao, Chunhong; Zhang, Shuliang; Misra, Manoj
2013-12-01
In vivo confocal Raman spectroscopy has become the measurement technique of choice for skin health and skin care related communities as a way of measuring functional chemistry aspects of skin that are key indicators for care and treatment of various skin conditions. Chief among these techniques are stratum corneum water content, a critical health indicator for severe skin condition related to dryness, and natural moisturizing factor components that are associated with skin protection and barrier health. In addition, in vivo Raman spectroscopy has proven to be a rapid and effective method for quantifying component penetration in skin for topically applied skin care formulations. The benefit of such a capability is that noninvasive analytical chemistry can be performed in vivo in a clinical setting, significantly simplifying studies aimed at evaluating product performance. This presumes, however, that the data and analysis methods used are compatible and appropriate for the intended purpose. The standard analysis method used by most researchers for in vivo Raman data is ordinary least squares (OLS) regression. The focus of work described in this paper is the applicability of OLS for in vivo Raman analysis with particular attention given to use for non-ideal data that often violate the inherent limitations and deficiencies associated with proper application of OLS. We then describe a newly developed in vivo Raman spectroscopic analysis methodology called multivariate curve resolution-augmented ordinary least squares (MCR-OLS), a relatively simple route to addressing many of the issues with OLS. The method is compared with the standard OLS method using the same in vivo Raman data set and using both qualitative and quantitative comparisons based on model fit error, adherence to known data constraints, and performance against calibration samples. A clear improvement is shown in each comparison for MCR-OLS over standard OLS, thus supporting the premise that the MCR-OLS method is better suited for general-purpose multicomponent analysis of in vivo Raman spectral data. This suggests that the methodology is more readily adaptable to a wide range of component systems and is thus more generally applicable than standard OLS.
In response to the 1996 legislative mandate for an endocrine screening and testing program, we are helping develop, standardize and validate relatively sensitive, robust and relatively simple methods for in vitro screening of chemicals that affect estrogen, and androgen function ...
RAMESES publication standards: meta-narrative reviews
2013-01-01
Background Meta-narrative review is one of an emerging menu of new approaches to qualitative and mixed-method systematic review. A meta-narrative review seeks to illuminate a heterogeneous topic area by highlighting the contrasting and complementary ways in which researchers have studied the same or a similar topic. No previous publication standards exist for the reporting of meta-narrative reviews. This publication standard was developed as part of the RAMESES (Realist And MEta-narrative Evidence Syntheses: Evolving Standards) project. The project's aim is to produce preliminary publication standards for meta-narrative reviews. Methods We (a) collated and summarized existing literature on the principles of good practice in meta-narrative reviews; (b) considered the extent to which these principles had been followed by published reviews, thereby identifying how rigor may be lost and how existing methods could be improved; (c) used a three-round online Delphi method with an interdisciplinary panel of national and international experts in evidence synthesis, meta-narrative reviews, policy and/or publishing to produce and iteratively refine a draft set of methodological steps and publication standards; (d) provided real-time support to ongoing meta-narrative reviews and the open-access RAMESES online discussion list so as to capture problems and questions as they arose; and (e) synthesized expert input, evidence review and real-time problem analysis into a definitive set of standards. Results We identified nine published meta-narrative reviews, provided real-time support to four ongoing reviews and captured questions raised in the RAMESES discussion list. Through analysis and discussion within the project team, we summarized the published literature, and common questions and challenges into briefing materials for the Delphi panel, comprising 33 members. Within three rounds this panel had reached consensus on 20 key publication standards, with an overall response rate of 90%. Conclusion This project used multiple sources to draw together evidence and expertise in meta-narrative reviews. For each item we have included an explanation for why it is important and guidance on how it might be reported. Meta-narrative review is a relatively new method for evidence synthesis and as experience and methodological developments occur, we anticipate that these standards will evolve to reflect further theoretical and methodological developments. We hope that these standards will act as a resource that will contribute to improving the reporting of meta-narrative reviews. To encourage dissemination of the RAMESES publication standards, this article is co-published in the Journal of Advanced Nursing and is freely accessible on Wiley Online Library (http://www.wileyonlinelibrary.com/journal/jan). Please see related articles http://www.biomedcentral.com/1741-7015/11/21 and http://www.biomedcentral.com/1741-7015/11/22 PMID:23360661
Estimating the mass variance in neutron multiplicity counting-A comparison of approaches
NASA Astrophysics Data System (ADS)
Dubi, C.; Croft, S.; Favalli, A.; Ocherashvili, A.; Pedersen, B.
2017-12-01
In the standard practice of neutron multiplicity counting , the first three sampled factorial moments of the event triggered neutron count distribution are used to quantify the three main neutron source terms: the spontaneous fissile material effective mass, the relative (α , n) production and the induced fission source responsible for multiplication. This study compares three methods to quantify the statistical uncertainty of the estimated mass: the bootstrap method, propagation of variance through moments, and statistical analysis of cycle data method. Each of the three methods was implemented on a set of four different NMC measurements, held at the JRC-laboratory in Ispra, Italy, sampling four different Pu samples in a standard Plutonium Scrap Multiplicity Counter (PSMC) well counter.
Estimating the mass variance in neutron multiplicity counting $-$ A comparison of approaches
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dubi, C.; Croft, S.; Favalli, A.
In the standard practice of neutron multiplicity counting, the first three sampled factorial moments of the event triggered neutron count distribution are used to quantify the three main neutron source terms: the spontaneous fissile material effective mass, the relative (α,n) production and the induced fission source responsible for multiplication. This study compares three methods to quantify the statistical uncertainty of the estimated mass: the bootstrap method, propagation of variance through moments, and statistical analysis of cycle data method. Each of the three methods was implemented on a set of four different NMC measurements, held at the JRC-laboratory in Ispra, Italy,more » sampling four different Pu samples in a standard Plutonium Scrap Multiplicity Counter (PSMC) well counter.« less
Estimating the mass variance in neutron multiplicity counting $-$ A comparison of approaches
Dubi, C.; Croft, S.; Favalli, A.; ...
2017-09-14
In the standard practice of neutron multiplicity counting, the first three sampled factorial moments of the event triggered neutron count distribution are used to quantify the three main neutron source terms: the spontaneous fissile material effective mass, the relative (α,n) production and the induced fission source responsible for multiplication. This study compares three methods to quantify the statistical uncertainty of the estimated mass: the bootstrap method, propagation of variance through moments, and statistical analysis of cycle data method. Each of the three methods was implemented on a set of four different NMC measurements, held at the JRC-laboratory in Ispra, Italy,more » sampling four different Pu samples in a standard Plutonium Scrap Multiplicity Counter (PSMC) well counter.« less
ERIC Educational Resources Information Center
Laurson, Kelly R.; Welk, Gregory J.; Marton, Orsolya; Kaj, Mónika; Csányi, Tamás
2015-01-01
Purpose: This study examined agreement between all 3 standards (as well as relative diagnostic associations with metabolic syndrome) using a representative sample of youth from the Hungarian National Youth Fitness Study. Method: Body mass index (BMI) was assessed in a field sample of 2,352 adolescents (ages 10-18.5 years) and metabolic syndrome…
Sun, Lei; Jin, Hong-Yu; Tian, Run-Tao; Wang, Ming-Juan; Liu, Li-Na; Ye, Liu-Ping; Zuo, Tian-Tian; Ma, Shuang-Cheng
2017-01-01
Analysis of related substances in pharmaceutical chemicals and multi-components in traditional Chinese medicines needs bulk of reference substances to identify the chromatographic peaks accurately. But the reference substances are costly. Thus, the relative retention (RR) method has been widely adopted in pharmacopoeias and literatures for characterizing HPLC behaviors of those reference substances unavailable. The problem is it is difficult to reproduce the RR on different columns due to the error between measured retention time (t R ) and predicted t R in some cases. Therefore, it is useful to develop an alternative and simple method for prediction of t R accurately. In the present study, based on the thermodynamic theory of HPLC, a method named linear calibration using two reference substances (LCTRS) was proposed. The method includes three steps, procedure of two points prediction, procedure of validation by multiple points regression and sequential matching. The t R of compounds on a HPLC column can be calculated by standard retention time and linear relationship. The method was validated in two medicines on 30 columns. It was demonstrated that, LCTRS method is simple, but more accurate and more robust on different HPLC columns than RR method. Hence quality standards using LCTRS method are easy to reproduce in different laboratories with lower cost of reference substances.
Determination of Trace lead (II) by Resonance Light Scattering Based on Pb (II)-KI-MG System
NASA Astrophysics Data System (ADS)
Chen, Ninghua; Yang, Yingchun; Hao, Shuai; Li, Yangmin
2018-01-01
In pH=3.0 weak acidic solution, it is found that Pb2+ can react with I-to form [PbI4]2-, and it further reacted with MG to form ion-association complex. As a result, the new spectra of RLS appeared and their intensities enhanced greatly. Accordingly, a new method developed for the determination of Pb (II).The appropriate reaction conditions were optimized through experiments. The results show that a strong and stable resonance scattering spectra emerge at the wavelength of 338 nm. The resonance light scattering strength (ΔIRLS) has good linear relationship with the concentration of Pb (II) in the range of 0.2 μg/mL ~ 1.0 μg/mL. The detection limits (LOD) is 0.0155 μg/mL. The relative standard deviation (RSD) is 3.61% (n=11) for the determination of 0.6 μg/mL Pb (II) standard solution. And this method was successfully applied to the determination of three environmental water samples (nongfu spring, tap water, laboratory wastewater). Results illustrate that the addition standard recovery are 80%~107% with relative standard deviation (RSD) between 1.8% to 4.6%.
Pulmonary lobar volumetry using novel volumetric computer-aided diagnosis and computed tomography
Iwano, Shingo; Kitano, Mariko; Matsuo, Keiji; Kawakami, Kenichi; Koike, Wataru; Kishimoto, Mariko; Inoue, Tsutomu; Li, Yuanzhong; Naganawa, Shinji
2013-01-01
OBJECTIVES To compare the accuracy of pulmonary lobar volumetry using the conventional number of segments method and novel volumetric computer-aided diagnosis using 3D computed tomography images. METHODS We acquired 50 consecutive preoperative 3D computed tomography examinations for lung tumours reconstructed at 1-mm slice thicknesses. We calculated the lobar volume and the emphysematous lobar volume < −950 HU of each lobe using (i) the slice-by-slice method (reference standard), (ii) number of segments method, and (iii) semi-automatic and (iv) automatic computer-aided diagnosis. We determined Pearson correlation coefficients between the reference standard and the three other methods for lobar volumes and emphysematous lobar volumes. We also compared the relative errors among the three measurement methods. RESULTS Both semi-automatic and automatic computer-aided diagnosis results were more strongly correlated with the reference standard than the number of segments method. The correlation coefficients for automatic computer-aided diagnosis were slightly lower than those for semi-automatic computer-aided diagnosis because there was one outlier among 50 cases (2%) in the right upper lobe and two outliers among 50 cases (4%) in the other lobes. The number of segments method relative error was significantly greater than those for semi-automatic and automatic computer-aided diagnosis (P < 0.001). The computational time for automatic computer-aided diagnosis was 1/2 to 2/3 than that of semi-automatic computer-aided diagnosis. CONCLUSIONS A novel lobar volumetry computer-aided diagnosis system could more precisely measure lobar volumes than the conventional number of segments method. Because semi-automatic computer-aided diagnosis and automatic computer-aided diagnosis were complementary, in clinical use, it would be more practical to first measure volumes by automatic computer-aided diagnosis, and then use semi-automatic measurements if automatic computer-aided diagnosis failed. PMID:23526418
USDA-ARS?s Scientific Manuscript database
Biodiesel is usually analyzed by the various methods called for in standards such as ASTM D6751 and EN 14214. Nuclear magnetic resonance (NMR) is not one of these methods. However, NMR, with 1H-NMR commonly applied, can be useful in a variety of applications related to biodiesel. These include monit...
A method for estimating operability and location of the timber resource.
John S. Jr. Spencer; Mark H. Hansen; Pamela J. Jakes
1986-01-01
Operability is the relative ease or difficulty of managing or harvesting timber because of physical conditions in the stand or on the site. Using data collected during standard statewide forest inventories, we developed a method for classifying timber by operability class based on seven operability components.
Problems and Methods of Teaching and Assessment of Students on Day Release in Higher Education.
ERIC Educational Resources Information Center
Trotman-Dickenson, Danusia
1980-01-01
Part-time students' characteristics and teaching and testing preferences were correlated with performance on a standardized economics exam. Learning modules are described. Methods of pinpointing student weaknesses and predicting students' final results are discussed as they relate to other subjects. (MSE)
29 CFR 2590.701-4 - Rules relating to creditable coverage.
Code of Federal Regulations, 2010 CFR
2010-07-01
... foreign country, or any political subdivision of a State, the U.S. government, or a foreign country that... Children's Health Insurance Program). (2) Excluded coverage. Creditable coverage does not include coverage... standard method described in paragraph (b) of this section. A plan or issuer may use the alternative method...
Systematic Desensitization as a Method of Teaching a General Anxiety-Reducing Skill
ERIC Educational Resources Information Center
Zemore, Robert
1975-01-01
College students were treated with either a standard or modified version of systematic desensitization. Relative to a no-treatment control group, both treatment methods produced significant reductions in both the treated and untreated fears. The implications these findings have for two alternative conceptions of systematic desensitization are…
In response to growing health concerns related to atmospheric fine particles, EPA promulgated in 1997 a new particulate matter standard accompanied by new sampling methodology. Based on a review of pertinent literature, a new metric (PM;,) was adopted and its measurement method...
21 CFR 172.215 - Coumarone-indene resin.
Code of Federal Regulations, 2011 CFR
2011-04-01
... mixture of indene, indan (hydrindene), substituted benzenes, and related compounds. (2) It contains no... additive meets the following specifications: (1) Softening point, ring and ball: 126 °C minimum as determined by ASTM method E28-67 (Reapproved 1982), “Standard Test Method for Softening Point by Ring-and...
21 CFR 172.215 - Coumarone-indene resin.
Code of Federal Regulations, 2012 CFR
2012-04-01
... mixture of indene, indan (hydrindene), substituted benzenes, and related compounds. (2) It contains no... additive meets the following specifications: (1) Softening point, ring and ball: 126 °C minimum as determined by ASTM method E28-67 (Reapproved 1982), “Standard Test Method for Softening Point by Ring-and...
21 CFR 172.215 - Coumarone-indene resin.
Code of Federal Regulations, 2013 CFR
2013-04-01
... mixture of indene, indan (hydrindene), substituted benzenes, and related compounds. (2) It contains no... additive meets the following specifications: (1) Softening point, ring and ball: 126 °C minimum as determined by ASTM method E28-67 (Reapproved 1982), “Standard Test Method for Softening Point by Ring-and...
Damrau, D.L.
1993-01-01
Increased awareness of the quality of water in the United States has led to the development of a method for determining low levels (0.2-5.0 microg/L) of silver in water samples. Use of graphite furnace atomic absorption spectrophotometry provides a sensitive, precise, and accurate method for determining low-level silver in samples of low ionic-strength water, precipitation water, and natural water. The minimum detection limit determined for low-level silver is 0.2 microg/L. Precision data were collected on natural-water samples and SRWS (Standard Reference Water Samples). The overall percent relative standard deviation for natural-water samples with silver concentrations more than 0.2 microg/L was less than 40 percent throughout the analytical range. For the SRWS with concentrations more than 0.2 microg/L, the overall percent relative standard deviation was less than 25 percent throughout the analytical range. The accuracy of the results was determined by spiking 6 natural-water samples with different known concentrations of the silver standard. The recoveries ranged from 61 to 119 percent at the 0.5-microg/L spike level. At the 1.25-microg/L spike level, the recoveries ranged from 92 to 106 percent. For the high spike level at 3.0 microg/L, the recoveries ranged from 65 to 113 percent. The measured concentrations of silver obtained from known samples were within the Branch of Quality Assurance accepted limits of 1 1/2 standard deviations on the basis of the SRWS program for Inter-Laboratory studies.
Zhang, Aizhi; Wang, Quanlin; Mo, Shijie
2010-11-01
A method for the simultaneous determination of delta-9-tetrahydrocannabinol (THC), cannabidiol (CBD) and cannabinol (CBN) in edible oil was developed using ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS). The target compounds were extracted with methanol, purified by an LC-Alumina-N solid phase extraction cartridge, separated and detected by the UPLC-MS/MS. Quantitative analysis was corrected by an isotope internal standard method using delta-9-THC-D3 as internal standard. Average recoveries for the target compounds varied from 68.0% to 101.6% with the relative standard deviations ranging from 7.0% to 20.1% at three spiked levels. The limits of detection (LOD) of the method were from 0.06-0.17 microg/kg and the limits of quantification (LOQ) were in the range of 0.20-0.52 microg/kg. The results showed that the method is able to meet the requirements for the simultaneous determination of THC, CBD and CBN in edible oil.
Wang, Jian-Hua; Guo, Cui
2010-07-09
An analytical method for the determination of US EPA priority pollutant 16 polycyclic aromatic hydrocarbons (PAHs) in edible oil was developed by an isotope dilution gas chromatography-mass spectrometry (GC-MS). Extraction was performed with ultrasonication mode using acetonitrile as solvent, and subsequent clean-up was applied using narrow gel permeation chromatographic column. Three deuterated PAHs surrogate standards were used as internal standards for quantification and analytical quality control. The limits of quantification (LOQs) were globally below 0.5 ng/g, the recoveries were in the range of 81-96%, and the relative standard deviations (RSDs) were lower than 20%. Further trueness assessment of the method was also verified through participation in international cocoa butter proficiency test (T0638) organised by the FAPAS with excellent results in 2008. The results obtained with the described method were satisfying (z ≤ 2). The method has been applied to determine PAH in real edible oil samples.
NASA Astrophysics Data System (ADS)
Ramanjaneyulu, P. S.; Sayi, Y. S.; Ramakumar, K. L.
2008-08-01
Quantification of boron in diverse materials of relevance in nuclear technology is essential in view of its high thermal neutron absorption cross section. A simple and sensitive method has been developed for the determination of boron in uranium-aluminum-silicon alloy, based on leaching of boron with 6 M HCl and H 2O 2, its selective separation by solvent extraction with 2-ethyl hexane 1,3-diol and quantification by spectrophotometry using curcumin. The method has been evaluated by standard addition method and validated by inductively coupled plasma-atomic emission spectroscopy. Relative standard deviation and absolute detection limit of the method are 3.0% (at 1 σ level) and 12 ng, respectively. All possible sources of uncertainties in the methodology have been individually assessed, following the International Organization for Standardization guidelines. The combined uncertainty is calculated employing uncertainty propagation formulae. The expanded uncertainty in the measurement at 95% confidence level (coverage factor 2) is 8.840%.
[Determination of trace gallium by graphite furnace atomic absorption spectrometry in urine].
Zhou, L Z; Fu, S; Gao, S Q; He, G W
2016-06-20
To establish a method for determination trace gallium in urine by graphite furnace atomic absorption spectrometry (GFAAS). The ammonium dihydrogen phosphate was matrix modifier. The temperature effect about pyrolysis (Tpyr) and atomization temperature were optimized for determination of trace gallium. The method of technical standard about within-run, between-run and recoveries of standard were optimized. The method showed a linear relationship within the range of 0.20~80.00 μg/L (r=0.998). The within-run and between-run relative standard deviations (RSD) of repetitive measurement at 5.0, 10.0, 20.0 μg/L concentration levels were 2.1%~5.5% and 2.3%~3.0%. The detection limit was 0.06 μg/L. The recoveries of gallium were 98.2%~101.1%. This method is simple, low detection limit, accurate, reliable and reproducible. It has been applied for determination of trace gallium in urine samples those who need occupation health examination or poisoning diagnosis.
Thomas, Jeanice B; Sharpless, Katherine E; Yen, James H; Rimmer, Catherine A
2011-01-01
The concentrations of selected fat-soluble vitamins and carotenoids in Standard Reference Material (SRM) 3280 Multivitamin/Multielement Tablets have been determined by two independent LC methods, with measurements performed by the National Institute of Standards and Technology (NIST). This SRM has been prepared as part of a collaborative effort between NIST and the National Institutes of Health Office of Dietary Supplements. The SRM is also intended to support the Dietary Supplement Ingredient Database that is being established by the U.S. Department of Agriculture. The methods used at NIST to determine the concentration levels of vitamins A and E, and beta-carotene in the SRM used RPLC with absorbance detection. The relative precision of these methods ranged from 2 to 8% for the analytes measured. SRM 3280 is primarily intended for use in validating analytical methods for the determination of selected vitamins, carotenoids, and elements in multivitamin/multielement tablets and similar matrixes.
Quantifying clutter: A comparison of four methods and their relationship to bat detection
Joy M. O’Keefe; Susan C. Loeb; Hoke S. Hill Jr.; J. Drew Lanham
2014-01-01
The degree of spatial complexity in the environment, or clutter, affects the quality of foraging habitats for bats and their detection with acoustic systems. Clutter has been assessed in a variety of ways but there are no standardized methods for measuring clutter. We compared four methods (Visual Clutter, Cluster, Single Variable, and Clutter Index) and related these...
Analysis of titanium content in titanium tetrachloride solution
NASA Astrophysics Data System (ADS)
Bi, Xiaoguo; Dong, Yingnan; Li, Shanshan; Guan, Duojiao; Wang, Jianyu; Tang, Meiling
2018-03-01
Strontium titanate, barium titan and lead titanate are new type of functional ceramic materials with good prospect, and titanium tetrachloride is a commonly in the production such products. Which excellent electrochemical performance of ferroelectric tempreature coefficient effect.In this article, three methods are used to calibrate the samples of titanium tetrachloride solution by back titration method, replacement titration method and gravimetric analysis method. The results show that the back titration method has many good points, for example, relatively simple operation, easy to judgment the titration end point, better accuracy and precision of analytical results, the relative standard deviation not less than 0.2%. So, it is the ideal of conventional analysis methods in the mass production.
NASA Astrophysics Data System (ADS)
Salminen, J.; Högström, R.; Saxholm, S.; Lakka, A.; Riski, K.; Heinonen, M.
2018-04-01
In this paper we present the development of a primary standard for dynamic pressures that is based on the drop weight method. At the moment dynamic pressure transducers are typically calibrated using reference transducers, which are calibrated against static pressure standards. Because dynamic and static characteristics of pressure transducers may significantly differ from each other, it is important that these transducers are calibrated against dynamic pressure standards. In a method developed in VTT Technical Research Centre of Finland Ltd, Centre for Metrology MIKES, a pressure pulse is generated by impact between a dropping weight and a piston of a liquid-filled piston-cylinder assembly. The traceability to SI-units is realized through interferometric measurement of the acceleration of the dropping weight during impact, the effective area of the piston-cylinder assembly and the mass of the weight. Based on experimental validation and an uncertainty evaluation, the developed primary standard provides traceability for peak pressures in the range from 10 MPa to 400 MPa with a few millisecond pulse width and a typical relative expanded uncertainty (k = 2) of 1.5%. The performance of the primary standard is demonstrated by test calibrations of two dynamic pressure transducers.
Kaizen method for esophagectomy patients: improved quality control, outcomes, and decreased costs.
Iannettoni, Mark D; Lynch, William R; Parekh, Kalpaj R; McLaughlin, Kelley A
2011-04-01
The majority of costs associated with esophagectomy are related to the initial 3 days of hospital stay requiring intensive care unit stays, ventilator support, and intraoperative time. Additional costs arise from hospital-based services. The major cost increases are related to complications associated with the procedure. We attempted to define these costs and identify expense management by streamlining care through strict adherence to patient care maps, operative standardization, and rapid discharge planning to reduce variability. Utilizing methods of Kaizen philosophy we evaluated all processes related to the entire experience of esophageal resection. This process has taken over 5 years to achieve, with quality and cost being tracked over this time period. Cost analysis included expenses related to intensive care unit, anesthesia, disposables, and hospital services. Quality improvement measures were related to intraoperative complications, in-hospital complications, and postoperative outcomes. The Institutional Review Board approved the use of anonymous data from standard clinical practice because no additional treatment was planned (observational study). Utilizing a continuous process improvement methodology, a 43% reduction in cost per case has been achieved with a significant increase in contribution margin for esophagectomy. The length of stay has been reduced from 14 days to 5. With intraoperative and postoperative standardization the leak rate has dropped from 12% to less than 3% to no leaks in our current Kaizen modification of care in our last 64 patients. Utilizing lean manufacturing techniques and continuous process evaluation we have attempted to eliminate variability, standardized the phases of care resulting in improved outcomes, decreased length of stay, and improved contribution margins. These Kaizen improvements require continuous interventions, strict adherence to care maps, and input from all levels for quality improvements. Copyright © 2011 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
Measurement of Outcomes in Vision-Related Rehabilitation.
ERIC Educational Resources Information Center
Head, Daniel
1998-01-01
Comments on an earlier article by Lorraine Lidoff on health insurance coverage of vision-related rehabilitation services. Urges a standard model of services involving selection of measurable outcomes that reflect treatment processes, selection of the most appropriate time to measure outcomes, and selection of the best method for collecting outcome…
Korany, Mohamed A; Maher, Hadir M; Galal, Shereen M; Ragab, Marwa A A
2013-05-01
This manuscript discusses the application and the comparison between three statistical regression methods for handling data: parametric, nonparametric, and weighted regression (WR). These data were obtained from different chemometric methods applied to the high-performance liquid chromatography response data using the internal standard method. This was performed on a model drug Acyclovir which was analyzed in human plasma with the use of ganciclovir as internal standard. In vivo study was also performed. Derivative treatment of chromatographic response ratio data was followed by convolution of the resulting derivative curves using 8-points sin x i polynomials (discrete Fourier functions). This work studies and also compares the application of WR method and Theil's method, a nonparametric regression (NPR) method with the least squares parametric regression (LSPR) method, which is considered the de facto standard method used for regression. When the assumption of homoscedasticity is not met for analytical data, a simple and effective way to counteract the great influence of the high concentrations on the fitted regression line is to use WR method. WR was found to be superior to the method of LSPR as the former assumes that the y-direction error in the calibration curve will increase as x increases. Theil's NPR method was also found to be superior to the method of LSPR as the former assumes that errors could occur in both x- and y-directions and that might not be normally distributed. Most of the results showed a significant improvement in the precision and accuracy on applying WR and NPR methods relative to LSPR.
Development of ASTM Standard for SiC-SiC Joint Testing Final Scientific/Technical Report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jacobsen, George; Back, Christina
2015-10-30
As the nuclear industry moves to advanced ceramic based materials for cladding and core structural materials for a variety of advanced reactors, new standards and test methods are required for material development and licensing purposes. For example, General Atomics (GA) is actively developing silicon carbide (SiC) based composite cladding (SiC-SiC) for its Energy Multiplier Module (EM2), a high efficiency gas cooled fast reactor. Through DOE funding via the advanced reactor concept program, GA developed a new test method for the nominal joint strength of an endplug sealed to advanced ceramic tubes, Fig. 1-1, at ambient and elevated temperatures called themore » endplug pushout (EPPO) test. This test utilizes widely available universal mechanical testers coupled with clam shell heaters, and specimen size is relatively small, making it a viable post irradiation test method. The culmination of this effort was a draft of an ASTM test standard that will be submitted for approval to the ASTM C28 ceramic committee. Once the standard has been vetted by the ceramics test community, an industry wide standard methodology to test joined tubular ceramic components will be available for the entire nuclear materials community.« less
Wong, Jacklyn; Bayoh, Nabie; Olang, George; Killeen, Gerry F; Hamel, Mary J; Vulule, John M; Gimnig, John E
2013-04-30
Operational vector sampling methods lack standardization, making quantitative comparisons of malaria transmission across different settings difficult. Human landing catch (HLC) is considered the research gold standard for measuring human-mosquito contact, but is unsuitable for large-scale sampling. This study assessed mosquito catch rates of CDC light trap (CDC-LT), Ifakara tent trap (ITT), window exit trap (WET), pot resting trap (PRT), and box resting trap (BRT) relative to HLC in western Kenya to 1) identify appropriate methods for operational sampling in this region, and 2) contribute to a larger, overarching project comparing standardized evaluations of vector trapping methods across multiple countries. Mosquitoes were collected from June to July 2009 in four districts: Rarieda, Kisumu West, Nyando, and Rachuonyo. In each district, all trapping methods were rotated 10 times through three houses in a 3 × 3 Latin Square design. Anophelines were identified by morphology and females classified as fed or non-fed. Anopheles gambiae s.l. were further identified as Anopheles gambiae s.s. or Anopheles arabiensis by PCR. Relative catch rates were estimated by negative binomial regression. When data were pooled across all four districts, catch rates (relative to HLC indoor) for An. gambiae s.l (95.6% An. arabiensis, 4.4% An. gambiae s.s) were high for HLC outdoor (RR = 1.01), CDC-LT (RR = 1.18), and ITT (RR = 1.39); moderate for WET (RR = 0.52) and PRT outdoor (RR = 0.32); and low for all remaining types of resting traps (PRT indoor, BRT indoor, and BRT outdoor; RR < 0.08 for all). For Anopheles funestus, relative catch rates were high for ITT (RR = 1.21); moderate for HLC outdoor (RR = 0.47), CDC-LT (RR = 0.69), and WET (RR = 0.49); and low for all resting traps (RR < 0.02 for all). At finer geographic scales, however, efficacy of each trap type varied from district to district. ITT, CDC-LT, and WET appear to be effective methods for large-scale vector sampling in western Kenya. Ultimately, choice of collection method for operational surveillance should be driven by trap efficacy and scalability, rather than fine-scale precision with respect to HLC. When compared with recent, similar trap evaluations in Tanzania and Zambia, these data suggest that traps which actively lure host-seeking females will be most useful for surveillance in the face of declining vector densities.
Hess, G.W.; Bohman, L.R.
1996-01-01
Techniques for estimating monthly mean streamflow at gaged sites and monthly streamflow duration characteristics at ungaged sites in central Nevada were developed using streamflow records at six gaged sites and basin physical and climatic characteristics. Streamflow data at gaged sites were related by regression techniques to concurrent flows at nearby gaging stations so that monthly mean streamflows for periods of missing or no record can be estimated for gaged sites in central Nevada. The standard error of estimate for relations at these sites ranged from 12 to 196 percent. Also, monthly streamflow data for selected percent exceedence levels were used in regression analyses with basin and climatic variables to determine relations for ungaged basins for annual and monthly percent exceedence levels. Analyses indicate that the drainage area and percent of drainage area at altitudes greater than 10,000 feet are the most significant variables. For the annual percent exceedence, the standard error of estimate of the relations for ungaged sites ranged from 51 to 96 percent and standard error of prediction for ungaged sites ranged from 96 to 249 percent. For the monthly percent exceedence values, the standard error of estimate of the relations ranged from 31 to 168 percent, and the standard error of prediction ranged from 115 to 3,124 percent. Reliability and limitations of the estimating methods are described.
Method for matching customer and manufacturer positions for metal product parameters standardization
NASA Astrophysics Data System (ADS)
Polyakova, Marina; Rubin, Gennadij; Danilova, Yulija
2018-04-01
Decision making is the main stage of regulation the relations between customer and manufacturer during the design the demands of norms in standards. It is necessary to match the positions of the negotiating sides in order to gain the consensus. In order to take into consideration the differences of customer and manufacturer estimation of the object under standardization process it is obvious to use special methods of analysis. It is proposed to establish relationships between product properties and its functions using functional-target analysis. The special feature of this type of functional analysis is the consideration of the research object functions and properties. It is shown on the example of hexagonal head crew the possibility to establish links between its functions and properties. Such approach allows obtaining a quantitative assessment of the closeness the positions of customer and manufacturer at decision making during the standard norms establishment.
Standardized Methods for Enhanced Quality and Comparability of Tuberculous Meningitis Studies.
Marais, Ben J; Heemskerk, Anna D; Marais, Suzaan S; van Crevel, Reinout; Rohlwink, Ursula; Caws, Maxine; Meintjes, Graeme; Misra, Usha K; Mai, Nguyen T H; Ruslami, Rovina; Seddon, James A; Solomons, Regan; van Toorn, Ronald; Figaji, Anthony; McIlleron, Helen; Aarnoutse, Robert; Schoeman, Johan F; Wilkinson, Robert J; Thwaites, Guy E
2017-02-15
Tuberculous meningitis (TBM) remains a major cause of death and disability in tuberculosis-endemic areas, especially in young children and immunocompromised adults. Research aimed at improving outcomes is hampered by poor standardization, which limits study comparison and the generalizability of results. We propose standardized methods for the conduct of TBM clinical research that were drafted at an international tuberculous meningitis research meeting organized by the Oxford University Clinical Research Unit in Vietnam. We propose a core dataset including demographic and clinical information to be collected at study enrollment, important aspects related to patient management and monitoring, and standardized reporting of patient outcomes. The criteria proposed for the conduct of observational and intervention TBM studies should improve the quality of future research outputs, can facilitate multicenter studies and meta-analyses of pooled data, and could provide the foundation for a global TBM data repository.
Nur, Nurhayati Mohd; Dawal, Siti Zawiah Md; Dahari, Mahidzal; Sanusi, Junedah
2015-01-01
[Purpose] This study investigated the variations in muscle fatigue, time to fatigue, and maximum task duration at different levels of production standard time. [Methods] Twenty subjects performed repetitive tasks at three different levels of production standard time corresponding to “normal”, “hard” and “very hard”. Surface electromyography was used to measure the muscle activity. [Results] The results showed that muscle activity was significantly affected by the production standard time level. Muscle activity increased twice in percentage as the production standard time shifted from hard to very hard (6.9% vs. 12.9%). The muscle activity increased over time, indicating muscle fatigue. The muscle fatigue rate increased for the harder production standard time (Hard: 0.105; Very hard: 0.115), which indicated the associated higher risk of work-related musculoskeletal disorders. Muscle fatigue was also found to occur earlier for hard and very hard production standard times. [Conclusion] It is recommended that the maximum task duration should not exceed 5.6, 2.9, and 2.2 hours for normal, hard, and very hard production standard times, respectively, in order to maintain work performance and minimize the risk of work-related musculoskeletal disorders. PMID:26311974
AlHeresh, Rawan; LaValley, Michael P; Coster, Wendy; Keysor, Julie J
2017-06-01
To evaluate construct validity and scoring methods of the world health organization-health and work performance questionnaire (HPQ) for people with arthritis. Construct validity was examined through hypothesis testing using the recommended guidelines of the consensus-based standards for the selection of health measurement instruments (COSMIN). The HPQ using the absolute scoring method showed moderate construct validity as four of the seven hypotheses were met. The HPQ using the relative scoring method had weak construct validity as only one of the seven hypotheses were met. The absolute scoring method for the HPQ is superior in construct validity to the relative scoring method in assessing work performance among people with arthritis and related rheumatic conditions; however, more research is needed to further explore other psychometric properties of the HPQ.
NASA Astrophysics Data System (ADS)
Zhai, Qing-zhou; Zhang, Xiao-xia; Huang, Chong
2008-03-01
A simple and sensitive kinetic-spectrophotometric method is developed for the determination of trace vanadium(V), based on the catalytic effect of vanadium(V) on the oxidation of DBM-arsenazo by potassium bromate in 0.0138 mol l -1 phosphoric acid medium and at 100 °C in the presence of citric acid as activator. The absorbance is measured at 528 nm with the fixed-time method. The optimization of the operating conditions regarding concentrations of the reagents, temperature and interferences are also investigated. The working curve is linear over the concentration range 0-20 ng ml -1 of vanadium(V) with good precision and accuracy and the detection limit was down to 3.44 ng l -1. The relative standard deviation for a standard solution of 14 ng ml -1 is 0.28% ( n = 11). The apparent activity energies of the catalytic reaction and the non-catalytic reaction are 73.48, 113.5 kJ/mol, respectively. The proposed method proved highly sensitive, selective and relatively rapid for the assay of vanadium at low-level range of 0-20 ng ml -1 without any pre-concentration step. Thw method was applied to the determination of vanadium(V) in steels, rice, flour, cabbage, potato, fish, shrimp and tea samples with satisfactory results. The obtained results for the steel samples were excellent agreement with the standard reference values. The analytical results of the rice, flour, cabbage, potato, fish, shrimp and tea samples were excellent agreement with those of atomic absorption spectrometry. The recovery experiments have been made for the rice, flour, cabbage, potato, fish, shrimp and tea samples except the steels; excellent results were obtained. The relative standard deviations were over the range of 0.18-2.60% and the recoveries were over the range of 98.00-102.4%, respectively. The analytical results obtained were satisfactory.
Chen, Pei; Bryden, Noella
2015-01-01
A single-laboratory validation was performed on a practical ultra-HPLC (UHPLC)-diode array detector (DAD)/tandem MS method for determination of yohimbine in yohimbe barks and related dietary supplements. Good separation was achieved using a Waters Acquity ethylene bridged hybrid C18 column with gradient elution using 0.1% (v/v) aqueous ammonium hydroxide and 0.1% ammonium hydroxide in methanol as the mobile phases. The method can separate corynanthine from yohimbine in yohimbe bark extract, which is critical for accurate quantitation of yohimbine in yohimbe bark and related dietary supplements. Accuracy of the method was demonstrated using standard addition methods. Both intraday and interday precisions of the method were good. The method can be used without MS since yohimbine concentration in yohimbe barks and related dietary supplements are usually high enough for DAD detection, which can make it an easy and economical method for routine analysis of yohimbe barks and related dietary supplements. On the other hand, the method can be used with MS if desired for more challenging work such as biological and/or clinical studies.
Liyanaarachchi, G V V; Mahanama, K R R; Somasiri, H P P S; Punyasiri, P A N
2018-02-01
The study presents the validation results of the method carried out for analysis of free amino acids (FAAs) in rice using l-theanine as the internal standard (IS) with o-phthalaldehyde (OPA) reagent using high-performance liquid chromatography-fluorescence detection. The detection and quantification limits of the method were in the range 2-16μmol/kg and 3-19μmol/kg respectively. The method had a wide working range from 25 to 600μmol/kg for each individual amino acid, and good linearity with regression coefficients greater than 0.999. Precision measured in terms of repeatability and reproducibility, expressed as percentage relative standard deviation (% RSD) was below 9% for all the amino acids analyzed. The recoveries obtained after fortification at three concentration levels were in the range 75-105%. In comparison to l-norvaline, findings revealed that l-theanine is suitable as an IS and the validated method can be used for FAA determination in rice. Copyright © 2017 Elsevier Ltd. All rights reserved.
Cheng, Dongwan; Zheng, Li; Hou, Junjie; Wang, Jifeng; Xue, Peng; Yang, Fuquan; Xu, Tao
2015-01-01
The absolute quantification of target proteins in proteomics involves stable isotope dilution coupled with multiple reactions monitoring mass spectrometry (SID-MRM-MS). The successful preparation of stable isotope-labeled internal standard peptides is an important prerequisite for the SID-MRM absolute quantification methods. Dimethyl labeling has been widely used in relative quantitative proteomics and it is fast, simple, reliable, cost-effective, and applicable to any protein sample, making it an ideal candidate method for the preparation of stable isotope-labeled internal standards. MRM mass spectrometry is of high sensitivity, specificity, and throughput characteristics and can quantify multiple proteins simultaneously, including low-abundance proteins in precious samples such as pancreatic islets. In this study, a new method for the absolute quantification of three proteases involved in insulin maturation, namely PC1/3, PC2 and CPE, was developed by coupling a stable isotope dimethyl labeling strategy for internal standard peptide preparation with SID-MRM-MS quantitative technology. This method offers a new and effective approach for deep understanding of the functional status of pancreatic β cells and pathogenesis in diabetes.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Miller, D.; Wohlgemuth, J.; Gu, X.
2013-11-01
The curing of cross-linkable encapsulation is a critical consideration for photovoltaic (PV) modules manufactured using a lamination process. Concerns related to ethylene-co-vinyl acetate (EVA) include the quality (e.g., expiration and uniformity) of the films or completion (duration) of the cross-linking of the EVA within a laminator. Because these issues are important to both EVA and module manufacturers, an international standard has recently been proposed by the Encapsulation Task-Group within the Working Group 2 (WG2) of the International Electrotechnical Commission (IEC) Technical Committee 82 (TC82) for the quantification of the degree of cure for EVA encapsulation. The present draft of themore » standard calls for the use of differential scanning calorimetry (DSC) as the rapid, enabling secondary (test) method. Both the residual enthalpy- and melt/freeze-DSC methods are identified. The DSC methods are calibrated against the gel content test, the primary (reference) method. Aspects of other established methods, including indentation and rotor cure metering, were considered by the group. Key details of the test procedure will be described.« less
Ong, E S; Yong, Y L; Woo, S O
1999-01-01
A simple, rapid, and sensitive method with high sample throughput was developed for determining arsenic in traditional Chinese medicine (TCM) in the form of uncoated tablets, sugar-coated tablets, black pills, capsules, powders, and syrups. The method involves microwave digestion with flow injection-inductively coupled plasma mass spectrometry (FI-ICP-MS). Method precision was 2.7-10.1% (relative standard deviation, n = 6) for different concentrations of arsenic in different TCM samples analyzed by different analysts on different days. Method accuracy was checked with a certified reference material (sea lettuce, Ulva lactuca, BCR CRM 279) for external calibration and by spiking arsenic standard into different TCMs. Recoveries of 89-92% were obtained for the certified reference material and higher than 95% for spiked TCMs. Matrix interference was insignificant for samples analyzed by the method of standard addition. Hence, no correction equation was used in the analysis of arsenic in the samples studied. Sample preparation using microwave digestion gave results that were very similar to those obtained by conventional wet acid digestion using nitric acid.
Gómez-Ordóñez, Eva; Jiménez-Escrig, Antonio; Rupérez, Pilar
2012-05-15
Biological properties of polysaccharides from seaweeds are related to their composition and structure. Many factors such as the kind of sugar, type of linkage or sulfate content of algal biopolymers exert an influence in the relationship between structure and function. Besides, the molecular weight (MW) also plays an important role. Thus, a simple, reliable and fast HPSEC method with refractive index detection was developed and optimized for the MW estimation of soluble algal polysaccharides. Chromatogram shape and repeatability of retention time was considerably improved when sodium nitrate was used instead of ultrapure water as mobile phase. Pullulan and dextran standards of different MW were used for method calibration and validation. Also, main polysaccharide standards from brown (alginate, fucoidan, laminaran) and red seaweeds (kappa- and iota-carrageenan) were used for quantification and method precision and accuracy. Relative standard deviation (RSD) of repeatability for retention time, peak areas and inter-day precision was below 0.7%, 2.5% and 2.6%, respectively, which indicated good repeatability and precision. Recoveries (96.3-109.8%) also showed its fairly good accuracy. Regarding linearity, main polysaccharide standards from brown or red seaweeds showed a highly satisfactory correlation coefficient (r>0.999). Moreover, a good sensitivity was shown, with corresponding limits of detection and quantitation in mg/mL of 0.05-0.21 and 0.16-0.31, respectively. The method was applied to the MW estimation of standard algal polysaccharides, as well as to the soluble polysaccharide fractions from the brown seaweed Saccharina latissima and the red Mastocarpus stellatus, respectively. Although distribution of molecular weight was broad, the good repeatability for retention time provided a good precision in MW estimation of polysaccharides. Water- and alkali-soluble fractions from S. latissima ranged from very high (>2400 kDa) to low MW compounds (<6 kDa); this high heterogeneity could be attributable to the complex polysaccharide composition of brown algae. Regarding M. stellatus, sulfated galactans followed a descending order of MW (>1400 kDa to <10 kDa), related to the different solubility of carrageenans in red seaweeds. In summary, the method developed allows for the molecular weight analysis of seaweed polysaccharides with very good precision, accuracy, linearity and sensitivity within a short time. Copyright © 2012 Elsevier B.V. All rights reserved.
Lenselink, Eelke B; Ten Dijke, Niels; Bongers, Brandon; Papadatos, George; van Vlijmen, Herman W T; Kowalczyk, Wojtek; IJzerman, Adriaan P; van Westen, Gerard J P
2017-08-14
The increase of publicly available bioactivity data in recent years has fueled and catalyzed research in chemogenomics, data mining, and modeling approaches. As a direct result, over the past few years a multitude of different methods have been reported and evaluated, such as target fishing, nearest neighbor similarity-based methods, and Quantitative Structure Activity Relationship (QSAR)-based protocols. However, such studies are typically conducted on different datasets, using different validation strategies, and different metrics. In this study, different methods were compared using one single standardized dataset obtained from ChEMBL, which is made available to the public, using standardized metrics (BEDROC and Matthews Correlation Coefficient). Specifically, the performance of Naïve Bayes, Random Forests, Support Vector Machines, Logistic Regression, and Deep Neural Networks was assessed using QSAR and proteochemometric (PCM) methods. All methods were validated using both a random split validation and a temporal validation, with the latter being a more realistic benchmark of expected prospective execution. Deep Neural Networks are the top performing classifiers, highlighting the added value of Deep Neural Networks over other more conventional methods. Moreover, the best method ('DNN_PCM') performed significantly better at almost one standard deviation higher than the mean performance. Furthermore, Multi-task and PCM implementations were shown to improve performance over single task Deep Neural Networks. Conversely, target prediction performed almost two standard deviations under the mean performance. Random Forests, Support Vector Machines, and Logistic Regression performed around mean performance. Finally, using an ensemble of DNNs, alongside additional tuning, enhanced the relative performance by another 27% (compared with unoptimized 'DNN_PCM'). Here, a standardized set to test and evaluate different machine learning algorithms in the context of multi-task learning is offered by providing the data and the protocols. Graphical Abstract .
Peterson, Sean M.; Streby, Henry M.; Lehman, Justin A.; Kramer, Gunnar R.; Fish, Alexander C.; Andersen, David E.
2015-01-01
We compared the efficacy of standard nest-searching methods with finding nests via radio-tagged birds to assess how search technique influenced our determination of nest-site characteristics and nest success for Golden-winged Warblers (Vermivora chrysoptera). We also evaluated the cost-effectiveness of using radio-tagged birds to find nests. Using standard nest-searching techniques for 3 populations, we found 111 nests in locations with habitat characteristics similar to those described in previous studies: edges between forest and relatively open areas of early successional vegetation or shrubby wetlands, with 43% within 5 m of forest edge. The 83 nests found using telemetry were about half as likely (23%) to be within 5 m of forest edge. We spent little time searching >25 m into forest because published reports state that Golden-winged Warblers do not nest there. However, 14 nests found using telemetry (18%) were >25 m into forest. We modeled nest success using nest-searching method, nest age, and distance to forest edge as explanatory variables. Nest-searching method explained nest success better than nest age alone; we estimated that nests found using telemetry were 10% more likely to fledge young than nests found using standard nest-searching methods. Although radio-telemetry was more expensive than standard nest searching, the cost-effectiveness of both methods differed depending on searcher experience, amount of equipment owned, and bird population density. Our results demonstrate that telemetry can be an effective method for reducing bias in Golden-winged Warbler nest samples, can be cost competitive with standard nest-searching methods in some situations, and is likely to be a useful approach for finding nests of other forest-nesting songbirds.
Statistical analysis of radioimmunoassay. In comparison with bioassay (in Japanese)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nakano, R.
1973-01-01
Using the data of RIA (radioimmunoassay), statistical procedures for dealing with two problems of the linearization of dose response curve and calculation of relative potency were described. There were three methods for linearization of dose response curve of RIA. In each method, the following parameters were shown on the horizontal and vertical axis: dose x, (B/T)/sup -1/; c/x + c, B/T (C: dose which makes B/T 50%); log x, logit B/T. Among them, the last method seems to be most practical. The statistical procedures for bioassay were employed for calculating the relative potency of unknown samples compared to the standardmore » samples from dose response curves of standand and unknown samples using regression coefficient. It is desirable that relative potency is calculated by plotting more than 5 points in the standard curve and plotting more than 2 points in unknow samples. For examining the statistical limit of precision of measuremert, LH activity of gonadotropin in urine was measured and relative potency, precision coefficient and the upper and lower limits of relative potency at 95% confidence limit were calculated. On the other hand, bioassay (by the ovarian ascorbic acid reduction method and anteriol lobe of prostate weighing method) was done in the same samples, and the precision was compared with that of RIA. In these examinations, the upper and lower limits of the relative potency at 95% confidence limit were near each other, while in bioassay, a considerable difference was observed between the upper and lower limits. The necessity of standardization and systematization of the statistical procedures for increasing the precision of RIA was pointed out. (JA)« less
Achieving Innovation and Affordability Through Standardization of Materials Development and Testing
NASA Technical Reports Server (NTRS)
Bray, M. H.; Zook, L. M.; Raley, R. E.; Chapman, C.
2011-01-01
The successful expansion of development, innovation, and production within the aeronautics industry during the 20th century was facilitated by collaboration of government agencies with the commercial aviation companies. One of the initial products conceived from the collaboration was the ANC-5 Bulletin, first published in 1937. The ANC-5 Bulletin had intended to standardize the requirements of various government agencies in the design of aircraft structure. The national space policy shift in priority for NASA with an emphasis on transferring the travel to low earth orbit to commercial space providers highlights an opportunity and a need for the national and global space industries. The same collaboration and standardization that is documented and maintained by the industry within MIL-HDBK-5 (MMPDS-01) and MIL-HBDK-17 (nonmetallic mechanical properties) can also be exploited to standardize the thermal performance properties, processing methods, test methods, and analytical methods for use in aircraft and spacecraft design and associated propulsion systems. In addition to the definition of thermal performance description and standardization, the standardization for test methods and analysis for extreme environments (high temperature, cryogenics, deep space radiation, etc) would also be highly valuable to the industry. Its subsequent revisions and conversion to MIL-HDBK-5 and then MMPDS-01 established and then expanded to contain standardized mechanical property design values and other related design information for metallic materials used in aircraft, missiles, and space vehicles. It also includes guidance on standardization of composition, processing, and analytical methods for presentation and inclusion into the handbook. This standardization enabled an expansion of the technologies to provide efficiency and reliability to the consumers. It can be established that many individual programs within the government agencies have been overcome with development costs generated from these nonstandard requirements. Without industry standardization and acceptance, the programs are driven to shoulder the costs of determining design requirements, performance criteria, and then material qualification and certification. A significant investment that the industry could make to both reduce individual program development costs and schedules while expanding commercial space flight capabilities would be to invest in standardizing material performance properties for high temperature, cryogenic, and deep space environments for both metallic and nonmetallic materials.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hunter, J. L.; Sutton, T. M.
2013-07-01
In Monte Carlo iterated-fission-source calculations relative uncertainties on local tallies tend to be larger in lower-power regions and smaller in higher-power regions. Reducing the largest uncertainties to an acceptable level simply by running a larger number of neutron histories is often prohibitively expensive. The uniform fission site method has been developed to yield a more spatially-uniform distribution of relative uncertainties. This is accomplished by biasing the density of fission neutron source sites while not biasing the solution. The method is integrated into the source iteration process, and does not require any auxiliary forward or adjoint calculations. For a given amountmore » of computational effort, the use of the method results in a reduction of the largest uncertainties relative to the standard algorithm. Two variants of the method have been implemented and tested. Both have been shown to be effective. (authors)« less
Arnold, David; Girling, Alan; Stevens, Andrew; Lilford, Richard
2009-07-22
Utilities (values representing preferences) for healthcare priority setting are typically obtained indirectly by asking patients to fill in a quality of life questionnaire and then converting the results to a utility using population values. We compared such utilities with those obtained directly from patients or the public. Review of studies providing both a direct and indirect utility estimate. Papers reporting comparisons of utilities obtained directly (standard gamble or time tradeoff) or indirectly (European quality of life 5D [EQ-5D], short form 6D [SF-6D], or health utilities index [HUI]) from the same patient. PubMed and Tufts database of utilities. Sign test for paired comparisons between direct and indirect utilities; least squares regression to describe average relations between the different methods. Mean utility scores (or median if means unavailable) for each method, and differences in mean (median) scores between direct and indirect methods. We found 32 studies yielding 83 instances where direct and indirect methods could be compared for health states experienced by adults. The direct methods used were standard gamble in 57 cases and time trade off in 60(34 used both); the indirect methods were EQ-5D (67 cases), SF-6D (13), HUI-2 (5), and HUI-3 (37). Mean utility values were 0.81 (standard gamble) and 0.77 (time tradeoff) for the direct methods; for the indirect methods: 0.59(EQ-5D), 0.63 (SF-6D), 0.75 (HUI-2) and 0.68 (HUI-3). Direct methods of estimating utilities tend to result in higher health ratings than the more widely used indirect methods, and the difference can be substantial.Use of indirect methods could have important implications for decisions about resource allocation: for example, non-lifesaving treatments are relatively more favoured in comparison with lifesaving interventions than when using direct methods.
Spectrofluorimetric determination of fluoroquinolones in pharmaceutical preparations.
Ulu, Sevgi Tatar
2009-02-01
Simple, rapid and highly sensitive spectrofluorimetric method is presented for the determination of four fluoroquinolone (FQ) drugs, ciprofloxacin, enoxacin, norfloxacin and moxifloxacin in pharmaceutical preparations. Proposed method is based on the derivatization of FQ with 4-chloro-7-nitrobenzofurazan (NBD-Cl) in borate buffer of pH 9.0 to yield a yellow product. The optimum experimental conditions have been studied carefully. Beer's law is obeyed over the concentration range of 23.5-500 ng mL(-1) for ciprofloxacin, 28.5-700 ng mL(-1) for enoxacin, 29.5-800 ng mL(-1) for norfloxacin and 33.5-1000 ng mL(-1) for moxifloxacin using NBD-Cl reagent, respectively. The detection limits were found to be 7.0 ng mL(-1) for ciprofloxacin, 8.5 ng mL(-1) for enoxacin, 9.2 ng mL(-1) for norfloxacin and 9.98 ng mL(-1) for moxifloxacin, respectively. Intra-day and inter-day relative standard deviation and relative mean error values at three different concentrations were determined. The low relative standard deviation values indicate good precision and high recovery values indicate accuracy of the proposed methods. The method is highly sensitive and specific. The results obtained are in good agreement with those obtained by the official and reference method. The results presented in this report show that the applied spectrofluorimetric method is acceptable for the determination of the four FQ in the pharmaceutical preparations. Common excipients used as additives in pharmaceutical preparations do not interfere with the proposed method.
Woo, Kang-Lyung
2005-01-01
Low molecular weight alcohols including fusel oil were determined using diethyl ether extraction and capillary gas chromatography. Twelve kinds of alcohols were successfully resolved on the HP-FFAP (polyethylene glycol) capillary column. The diethyl ether extraction method was very useful for the analysis of alcohols in alcoholic beverages and biological samples with excellent cleanliness of the resulting chromatograms and high sensitivity compared to the direct injection method. Calibration graphs for all standard alcohols showed good linearity in the concentration range used, 0.001-2% (w/v) for all alcohols. Salting out effects were significant (p < 0.01) for the low molecular weight alcohols methanol, isopropanol, propanol, 2-butanol, n-butanol and ethanol, but not for the relatively high molecular weight alcohols amyl alcohol, isoamyl alcohol, and heptanol. The coefficients of variation of the relative molar responses were less than 5% for all of the alcohols. The limits of detection and quantitation were 1-5 and 10-60 microg/L for the diethyl ether extraction method, and 10-50 and 100-350 microg/L for the direct injection method, respectively. The retention times and relative retention times of standard alcohols were significantly shifted in the direct injection method when the injection volumes were changed, even with the same analysis conditions, but they were not influenced in the diethyl ether extraction method. The recoveries by the diethyl ether extraction method were greater than 95% for all samples and greater than 97% for biological samples.
Peedikayil, Musthafa Chalikandy; AlSohaibani, Fahad Ibrahim; Alkhenizan, Abdullah Hamad
2014-01-01
Background First-line levofloxacin-based treatments eradicate Helicobacter pylori with varying success. We examined the efficacy and safety of first-line levofloxacin-based treatment in comparison to standard first-line therapy for H pylori eradication. Materials and Methods We searched literature databases from Medline, EMBASE, and the Cochrane Register of Randomized Controlled Trials through March 2013 for randomized controlled trials comparing first-line levofloxacin and standard therapy. We included randomized controlled trials conducted only on naïve H pylori infected patients in adults. A systematic review was conducted. Meta-analysis was performed with Review Manager 5.2. Treatment effect was determined by relative risk with a random or fixed model by the Mantel-Haenszel method. Results Seven trials were identified with 888 patients receiving 7 days of first-line levofloxacin and 894 treated with standard therapy (Amoxicillin, Clarithromycin and proton pump inhibitor) for 7 days. The overall crude eradication rate in the Levofloxacin group was 79.05% versus 81.4% in the standard group (risk ratio 0.97; 95% CI; 0.93, 1.02). The overall dropout was 46 (5.2%) in the levofloxacin group and 52 (5.8%) for standard therapy. The dizziness was more common among group who took Levofloxacin based treatment and taste disturbance was more common among group who took standard therapy. Meta-analysis of overall adverse events were similar between the two groups with a relative risk of 1.06 (95% CI 0.72, 1.57). Conclusion Helicobacter pylori eradication with 7 days of Levofloxacin-based first line therapy was safe and equal compared to 7 days of standard first-line therapy. PMID:24465624
Sabzghabaei, Foroogh; Salajeghe, Mahla; Soltani Arabshahi, Seyed Kamran
2017-01-01
Background: In this study, ambulatory care training in Firoozgar hospital was evaluated based on Iranian national standards of undergraduate medical education related to ambulatory education using Baldrige Excellence Model. Moreover, some suggestions were offered to promote education quality in the current condition of ambulatory education in Firoozgar hospital and national standards using the gap analysis method. Methods: This descriptive analytic study was a kind of evaluation research performed using the standard check lists published by the office of undergraduate medical education council. Data were collected through surveying documents, interviewing, and observing the processes based on the Baldrige Excellence Model. After confirming the validity and reliability of the check lists, we evaluated the establishment level of the national standards of undergraduate medical education in the clinics of this hospital in the 4 following domains: educational program, evaluation, training and research resources, and faculty members. Data were analyzed according to the national standards of undergraduate medical education related to ambulatory education and the Baldrige table for scoring. Finally, the quality level of the current condition was determined as very appropriate, appropriate, medium, weak, and very weak. Results: In domains of educational program 62%, in evaluation 48%, in training and research resources 46%, in faculty members 68%, and in overall ratio, 56% of the standards were appropriate. Conclusion: The most successful domains were educational program and faculty members, but evaluation and training and research resources domains had a medium performance. Some domains and indicators were determined as weak and their quality needed to be improved, so it is suggested to provide the necessary facilities and improvements by attending to the quality level of the national standards of ambulatory education PMID:29951400
The purpose of this SOP is to describe procedures for using and maintaining the local area network (LAN) and related microcomputer equipment at the Health Related Professions site at the University of Arizona. These methods were used for all data operations and maintenance routi...
ERIC Educational Resources Information Center
Berger, Dan; Wild, Charles
2017-01-01
Teaching standards within the UK's higher education sector are under unprecedented scrutiny not only in terms of perceived "highly variable" standards of teaching but also in relation to the clear attainment gap between black, Asian and minority ethnic (BAME) students and their white counterparts. Gentle taps at the door to the higher…
Sovio, Ulla; Smith, Gordon C S
2018-02-01
It has been proposed that correction of offspring weight percentiles (customization) might improve the prediction of adverse pregnancy outcome; however, the approach is not accepted universally. A complication in the interpretation of the data is that the main method for calculation of customized percentiles uses a fetal growth standard, and multiple analyses have compared the results with birthweight-based standards. First, we aimed to determine whether women who deliver small-for-gestational-age infants using a customized standard differed from other women. Second, we aimed to compare the association between birthweight percentile and adverse outcome using 3 different methods for percentile calculation: (1) a noncustomized actual birthweight standard, (2) a noncustomized fetal growth standard, and (3) a fully customized fetal growth standard. We analyzed data from the Pregnancy Outcome Prediction study, a prospective cohort study of nulliparous women who delivered in Cambridge, UK, between 2008 and 2013. We used a composite adverse outcome, namely, perinatal morbidity or preeclampsia. Receiver operating characteristic curve analysis was used to compare the 3 methods of calculating birthweight percentiles in relation to the composite adverse outcome. We confirmed previous observations that delivering an infant who was small for gestational age (<10th percentile) with the use of a fully customized fetal growth standard but who was appropriate for gestational age with the use of a noncustomized actual birthweight standard was associated with higher rates of adverse outcomes. However, we also observed that the mothers of these infants were 3-4 times more likely to be obese and to deliver preterm. When we compared the risk of adverse outcome from logistic regression models that were fitted to the birthweight percentiles that were derived by each of the 3 predefined methods, the areas under the receiver operating characteristic curves were similar for all 3 methods: 0.56 (95% confidence interval, 0.54-0.59) fully customized, 0.56 (95% confidence interval, 0.53-0.59) noncustomized fetal weight standard, and 0.55 (95% confidence interval, 0.53-0.58) noncustomized actual birthweight standard. When we classified the top 5% of predicted risk as high risk, the methods that used a fetal growth standard showed attenuation after adjustment for gestational age, whereas the birthweight standard did not. Further adjustment for the maternal characteristics, which included weight, attenuated the association with the customized standard, but not the other 2 methods. The associations after full adjustment were similar when we compared the 3 approaches. The independent association between birthweight percentile and adverse outcome was similar when we compared actual birthweight standards and fetal growth standards and compared customized and noncustomized standards. Use of fetal weight standards and customized percentiles for maternal characteristics could lead to stronger associations with adverse outcome through confounding by preterm birth and maternal obesity. Copyright © 2017 Elsevier Inc. All rights reserved.
Kovner, Christine; Harrington, Charlene; Greene, William; Mezey, Mathy
2009-01-01
Objective To examine the relationships between nursing staffing levels and nursing home deficiencies. Methods This panel data analysis employed random-effect models that adjusted for unobserved, nursing home–specific heterogeneity over time. Data were obtained from California's long-term care annual cost report data and the Automated Certification and Licensing Administrative Information and Management Systems data from 1999 to 2003, linked with other secondary data sources. Results Both total nursing staffing and registered nurse (RN) staffing levels were negatively related to total deficiencies, quality of care deficiencies, and serious deficiencies that may cause harm or jeopardy to nursing home residents. Nursing homes that met the state staffing standard received fewer total deficiencies and quality of care deficiencies than nursing homes that failed to meet the standard. Meeting the state staffing standard was not related to receiving serious deficiencies. Conclusions Total nursing staffing and RN staffing levels were predictors of nursing home quality. Further research is needed on the effectiveness of state minimum staffing standards. PMID:19181692
Revision of the NIST Standard for (223)Ra: New Measurements and Review of 2008 Data.
Zimmerman, B E; Bergeron, D E; Cessna, J T; Fitzgerald, R; Pibida, L
2015-01-01
After discovering a discrepancy in the transfer standard currently being disseminated by the National Institute of Standards and Technology (NIST), we have performed a new primary standardization of the alpha-emitter (223)Ra using Live-timed Anticoincidence Counting (LTAC) and the Triple-to-Double Coincidence Ratio Method (TDCR). Additional confirmatory measurements were made with the CIEMAT-NIST efficiency tracing method (CNET) of liquid scintillation counting, integral γ-ray counting using a NaI(Tl) well counter, and several High Purity Germanium (HPGe) detectors in an attempt to understand the origin of the discrepancy and to provide a correction. The results indicate that a -9.5 % difference exists between activity values obtained using the former transfer standard relative to the new primary standardization. During one of the experiments, a 2 % difference in activity was observed between dilutions of the (223)Ra master solution prepared using the composition used in the original standardization and those prepared using 1 mol·L(-1) HCl. This effect appeared to be dependent on the number of dilutions or the total dilution factor to the master solution, but the magnitude was not reproducible. A new calibration factor ("K-value") has been determined for the NIST Secondary Standard Ionization Chamber (IC "A"), thereby correcting the discrepancy between the primary and secondary standards.
Cueto Díaz, Sergio; Ruiz Encinar, Jorge; García Alonso, J Ignacio
2014-09-24
We present a novel method for the purity assessment of peptide standards which is applicable to any water soluble peptide. The method is based on the online (13)C isotope dilution approach in which the peptide is separated from its related impurities by liquid chromatography (LC) and the eluent is mixed post-column with a continuous flow of (13)C-enriched sodium bicarbonate. An online oxidation step using sodium persulfate in acidic media at 99°C provides quantitative oxidation to (12)CO2 and (13)CO2 respectively which is extracted to a gaseous phase with the help of a gas permeable membrane. The measurement of the isotope ratio 44/45 in the mass spectrometer allows the construction of the mass flow chromatogram. As the only species that is finally measured in the mass spectrometer is CO2, the peptide content in the standard can be quantified, on the base of its carbon content, using a generic primary standard such as potassium hydrogen phthalate. The approach was validated by the analysis of a reference material (NIST 8327), and applied to the quantification of two commercial synthetic peptide standards. In that case, the results obtained were compared with those obtained using alternative methods, such as amino acid analysis and ICP-MS. The results obtained proved the value of the method for the fast, accurate and precise mass purity assignment of synthetic peptide standards. Copyright © 2014 Elsevier B.V. All rights reserved.
NASA Technical Reports Server (NTRS)
Hughes, Vernon W.
1959-01-01
The use of a rotational state transition as observed by the molecular beam electric resonance method is discussed as a possible frequency standard particularly in the millimeter wavelength range. As a promising example the 100 kMc transition between the J = 0 and J = 1 rotational states of Li 6F19 is considered. The relative insensitivity of the transition frequency to external electric and magnetic fields and the low microwave power requirements appear favorable; the small fraction of the molecular beam that is in a single rotational state is a limiting factor.
Backe, Will J; Day, Thomas C; Field, Jennifer A
2013-05-21
A new analytical method was developed to quantify 26 newly-identified and 21 legacy (e.g. perfluoroalkyl carboxylates, perfluoroalkyl sulfonates, and fluorotelomer sulfonates) per and polyfluorinated alkyl substances (PFAS) in groundwater and aqueous film forming foam (AFFF) formulations. Prior to analysis, AFFF formulations were diluted into methanol and PFAS in groundwater were micro liquid-liquid extracted. Methanolic dilutions of AFFF formulations and groundwater extracts were analyzed by large-volume injection (900 μL) high-performance liquid chromatography tandem mass spectrometry. Orthogonal chromatography was performed using cation exchange (silica) and anion exchange (propylamine) guard columns connected in series to a reverse-phase (C18) analytical column. Method detection limits for PFAS in groundwater ranged from 0.71 ng/L to 67 ng/L, and whole-method accuracy ranged from 96% to 106% for analytes for which matched authentic analytical standards were available. For analytes without authentic analytical standards, whole-method accuracy ranged from 78 % to 144 %, and whole-method precision was less than 15 % relative standard deviation for all analytes. A demonstration of the method on groundwater samples from five military bases revealed eight of the 26 newly-identified PFAS present at concentrations up to 6900 ng/L. The newly-identified PFAS represent a minor fraction of the fluorinated chemicals in groundwater relative to legacy PFAS. The profiles of PFAS in groundwater differ from those found in fluorotelomer- and electrofluorination-based AFFF formulations, which potentially indicates environmental transformation of PFAS.
Extracting insights from the shape of complex data using topology
Lum, P. Y.; Singh, G.; Lehman, A.; Ishkanov, T.; Vejdemo-Johansson, M.; Alagappan, M.; Carlsson, J.; Carlsson, G.
2013-01-01
This paper applies topological methods to study complex high dimensional data sets by extracting shapes (patterns) and obtaining insights about them. Our method combines the best features of existing standard methodologies such as principal component and cluster analyses to provide a geometric representation of complex data sets. Through this hybrid method, we often find subgroups in data sets that traditional methodologies fail to find. Our method also permits the analysis of individual data sets as well as the analysis of relationships between related data sets. We illustrate the use of our method by applying it to three very different kinds of data, namely gene expression from breast tumors, voting data from the United States House of Representatives and player performance data from the NBA, in each case finding stratifications of the data which are more refined than those produced by standard methods. PMID:23393618
Extracting insights from the shape of complex data using topology.
Lum, P Y; Singh, G; Lehman, A; Ishkanov, T; Vejdemo-Johansson, M; Alagappan, M; Carlsson, J; Carlsson, G
2013-01-01
This paper applies topological methods to study complex high dimensional data sets by extracting shapes (patterns) and obtaining insights about them. Our method combines the best features of existing standard methodologies such as principal component and cluster analyses to provide a geometric representation of complex data sets. Through this hybrid method, we often find subgroups in data sets that traditional methodologies fail to find. Our method also permits the analysis of individual data sets as well as the analysis of relationships between related data sets. We illustrate the use of our method by applying it to three very different kinds of data, namely gene expression from breast tumors, voting data from the United States House of Representatives and player performance data from the NBA, in each case finding stratifications of the data which are more refined than those produced by standard methods.
Development of a Pancake-Making Method for a Batter-Based Product
USDA-ARS?s Scientific Manuscript database
Cake and pancake are major batter-based products made with soft wheat flour. A standardized baking method for high-ratio cake has been widely used for evaluating the cake-baking performance of soft wheat flour. Chlorinated flour is used to make high-ratio cake, and the cake formula contains relative...
21 CFR 172.215 - Coumarone-indene resin.
Code of Federal Regulations, 2014 CFR
2014-04-01
...), substituted benzenes, and related compounds. (2) It contains no more than 0.25 percent tar bases. (3) 95...) Softening point, ring and ball: 126 °C minimum as determined by ASTM method E28-67 (Reapproved 1982), “Standard Test Method for Softening Point by Ring-and-Ball Apparatus,” which is incorporated by reference...
NASA Technical Reports Server (NTRS)
Hughes, William O.; McNelis, Anne M.; Chris Nottoli; Eric Wolfram
2015-01-01
The absorption coefficient for material specimens are needed to quantify the expected acoustic performance of that material in its actual usage and environment. The ASTM C423-09a standard, "Standard Test Method for Sound Absorption and Sound Absorption Coefficients by the Reverberant Room Method" is often used to measure the absorption coefficient of material test specimens. This method has its basics in the Sabine formula. Although widely used, the interpretation of these measurements are a topic of interest. For example, in certain cases the measured Sabine absorption coefficients are greater than 1.0 for highly absorptive materials. This is often attributed to the diffraction edge effect phenomenon. An investigative test program to measure the absorption properties of highly absorbent melamine foam has been performed at the Riverbank Acoustical Laboratories. This paper will present and discuss the test results relating to the effect of the test materials' surface area, thickness and edge sealing conditions. A follow-on paper is envisioned that will present and discuss the results relating to the spacing between multiple piece specimens, and the mounting condition of the test specimen.
Burkhardt, Mark R.; Cinotto, Pete J.; Frahm, Galen W.; Woodworth, Mark T.; Pritt, Jeffrey W.
1995-01-01
A method for the determination of methylene blue active substances in whole-water samples by liquid-liquid extraction and spectrophotometric detection is described. Sulfate and sulfonate-based surfectants are reacted with methylene blue to form a blue-colored complex. The complex is extracted into chloroform, back-washed with an acidified phosphate-based buffer solution, and measured against external standards with a probe spectrophotometer. The method detection limt for routine analysis is 0.02 milligram per liter. The precision is plus/minus 10 percent relative standard deviation. The positive bias from nitrate and chloride and U.S. Geological Survey method O-3111-83 for methylene blue active substances is minized by adding a back-washing step.
Relative Displacement Method for Track-Structure Interaction
Ramos, Óscar Ramón; Pantaleón, Marcos J.
2014-01-01
The track-structure interaction effects are usually analysed with conventional FEM programs, where it is difficult to implement the complex track-structure connection behaviour, which is nonlinear, elastic-plastic and depends on the vertical load. The authors developed an alternative analysis method, which they call the relative displacement method. It is based on the calculation of deformation states in single DOF element models that satisfy the boundary conditions. For its solution, an iterative optimisation algorithm is used. This method can be implemented in any programming language or analysis software. A comparison with ABAQUS calculations shows a very good result correlation and compliance with the standard's specifications. PMID:24634610
Upcoming new international measurement standards in the field of building acoustics
NASA Astrophysics Data System (ADS)
Goydke, Hans
2002-11-01
The extensively completed revision of most of the ISO measurement standards in building acoustics mainly initiated by the European Commissions demand for harmonized standards emphasized the insight that the main goal to avoid trade barriers between the countries can only be reached when the standards sufficiently and comprehensively cover the field when they are related to the actual state of the art and when they are sufficiently related to practice. In modern architecture one can observe the rapid change in the use of building materials, for instance regarding the use of glass. Lightweight constructions as well as heavyweight building elements with additional linings are increasingly in common use and unquestionably there are consequences to be considered regarding the ascertainment of sound insulation properties. Besides others, International Standardization is unsatisfactory regarding the assessment of noise in buildings from waste water installations, in the low frequency area and in general regarding the expression of uncertainty of measurements. Intensity measurements in building acoustics, rainfall noise assessment, estimation of sound insulation, impulse response measurement methods, assessment of sound scattering are examples of upcoming standards.
Comparing the Methodologies in ASTM G198 Using Combined Hygrothermal-Corrosion Modeling
Samuel L. Zelinka
2013-01-01
ASTM G198, âStandard test method for determining the relative corrosion performance of driven fasteners in contact with treated wood,â was accepted by consensus and published in 2011. The method has two different exposure conditions for determining fastener corrosion performance in treated wood. The first method places the wood and embedded fasteners in a...
2013-01-01
Background Although on the decline, smoking-related fires remain a leading cause of fire death in the United States and United Kingdom and account for over 10% of fire-related deaths worldwide. This has prompted lawmakers to enact legislation requiring manufacturers to implement reduced ignition propensity (RIP) safety standards for cigarettes. The current research evaluates how implementation of RIP safety standards in different countries influenced smokers’ perceptions of cigarette self-extinguishment, frequency of extinguishment, and the impact on consumer smoking behaviors, including cigarettes smoked per day and planning to quit. Methods Participants for this research come from Waves 3 through 8 of the International Tobacco Control (ITC) Four Country Survey conducted longitudinally from 2004 through 2011 in the United States, United Kingdom, Australia, and Canada. Results Perceptions of cigarette self-extinguishment and frequency of extinguishment increased concurrently with an increase in the prevalence of RIP safety standards for cigarettes. Presence of RIP safety standards was also associated with a greater intention to quit smoking, but was not associated with the number of cigarettes smoked per day. Intention to quit was higher among those who were more likely to report that their cigarettes self-extinguish sometimes and often, but we found no evidence of an interaction between frequency of extinguishment and RIP safety standards on quit intentions. Conclusions Overall, because these standards largely do not influence consumer smoking behavior, RIP implementation may significantly reduce the number of cigarette-related fires and the associated death and damages. Further research should assess how implementation of RIP safety standards has influenced smoking-related fire incidence, deaths, and other costs associated with smoking-related fires. PMID:24359292
Cetin, Sevil Müge; Atmaca, Sedef
2004-03-26
A simple and reliable high-performance liquid chromatographic (HPLC) method with UV-Vis detection has been developed and validated for the determination of vigabatrin (VG) in human plasma and urine. The samples were pre-column derivatizated with 1,2-naphthoquinone-4-sulphonic acid sodium salt (NQS). A good chromatographic separation was achieved on a C18 column with a mobile phase consisting of acetonitrile and 10 mM orthophosphoric acid (pH 2.5) gradient elution. Tranexamic acid was used as an internal standard (I.S.). The method was linear over the concentration range of 0.8-30.0 microg/ml for both samples. The method is precise (relative standard deviation (R.S.D.) <9.13%) and accurate (relative mean error (RME) <-8.75%); analytical recoveries were 81.07% for plasma and 83.05% for urine. The assay was applied to pharmacokinetic study in a healthy volunteer after a single oral administration of 1 g of vigabatrin.
Comparing rapid and culture indicator bacteria methods at inland lake beaches
Francy, Donna S.; Bushon, Rebecca N.; Brady, Amie M.G.; Kephart, Christopher M.
2013-01-01
A rapid method, quantitative polymerase chain reaction (qPCR), for quantifying indicator bacteria in recreational waters is desirable for public health protection. We report that replacing current Escherichia coli standards with new US Environmental Protection Agency beach action values (BAVs) for enterococci by culture or qPCR may result in more advisories being posted at inland recreational lakes. In this study, concentrations of E. coli and enterococci by culture methods were compared to concentrations of Enterococcus spp. by qPCR at 3 inland lake beaches in Ohio. The E. coli and enterococci culture results were significantly related at all beaches; however, the relations between culture results and Enterococcus spp. qPCR results were not always significant and differed among beaches. All the qPCR results exceeded the new BAV for Enterococcus spp. by qPCR, whereas only 23.7% of culture results for E. coli and 79% of culture results for enterococci exceeded the current standard for E. coli or BAV for enterococci.
Wei, Liang
2010-01-01
A simple, rapid and sensitive method was proposed for online determination of tannic acid in colored tannery wastewater by automatic reference flow injection analysis. Based on the tannic acid reduction phosphotungstic acid to form blue compound in pH 12.38 alkaline solutions, the shade of blue compound is in a linear relation to the content of tannic acid at the point of the maximum absorption peak of 760 nm. The optimal experimental conditions had been obtained. The linear range of the proposed method was between 200 μg L−1 to 80 mg L−1 and the detection limit was 0.58 μg L−1. The relative standard deviation was 3.08% and 2.43% for 500 μg L−1 and 40 mg L−1 of tannic acid standard solution, respectively, (n = 10). The method had been successfully applied to determination of tannic acid in colored tannery wastewaters and the analytical results were satisfactory. PMID:20508812
How recalibration method, pricing, and coding affect DRG weights
Carter, Grace M.; Rogowski, Jeannette A.
1992-01-01
We compared diagnosis-related group (DRG) weights calculated using the hospital-specific relative-value (HSR V) methodology with those calculated using the standard methodology for each year from 1985 through 1989 and analyzed differences between the two methods in detail for 1989. We provide evidence suggesting that classification error and subsidies of higher weighted cases by lower weighted cases caused compression in the weights used for payment as late as the fifth year of the prospective payment system. However, later weights calculated by the standard method are not compressed because a statistical correlation between high markups and high case-mix indexes offsets the cross-subsidization. HSR V weights from the same files are compressed because this methodology is more sensitive to cross-subsidies. However, both sets of weights produce equally good estimates of hospital-level costs net of those expenses that are paid by outlier payments. The greater compression of the HSR V weights is counterbalanced by the fact that more high-weight cases qualify as outliers. PMID:10127456
Matched Comparison Group Design Standards in Systematic Reviews of Early Childhood Interventions.
Thomas, Jaime; Avellar, Sarah A; Deke, John; Gleason, Philip
2017-06-01
Systematic reviews assess the quality of research on program effectiveness to help decision makers faced with many intervention options. Study quality standards specify criteria that studies must meet, including accounting for baseline differences between intervention and comparison groups. We explore two issues related to systematic review standards: covariate choice and choice of estimation method. To help systematic reviews develop/refine quality standards and support researchers in using nonexperimental designs to estimate program effects, we address two questions: (1) How well do variables that systematic reviews typically require studies to account for explain variation in key child and family outcomes? (2) What methods should studies use to account for preexisting differences between intervention and comparison groups? We examined correlations between baseline characteristics and key outcomes using Early Childhood Longitudinal Study-Birth Cohort data to address Question 1. For Question 2, we used simulations to compare two methods-matching and regression adjustment-to account for preexisting differences between intervention and comparison groups. A broad range of potential baseline variables explained relatively little of the variation in child and family outcomes. This suggests the potential for bias even after accounting for these variables, highlighting the need for systematic reviews to provide appropriate cautions about interpreting the results of moderately rated, nonexperimental studies. Our simulations showed that regression adjustment can yield unbiased estimates if all relevant covariates are used, even when the model is misspecified, and preexisting differences between the intervention and the comparison groups exist.
Cífková, Eva; Holčapek, Michal; Lísa, Miroslav; Ovčačíková, Magdaléna; Lyčka, Antonín; Lynen, Frédéric; Sandra, Pat
2012-11-20
The identification and quantitation of a wide range of lipids in complex biological samples is an essential requirement for the lipidomic studies. High-performance liquid chromatography-mass spectrometry (HPLC/MS) has the highest potential to obtain detailed information on the whole lipidome, but the reliable quantitation of multiple lipid classes is still a challenging task. In this work, we describe a new method for the nontargeted quantitation of polar lipid classes separated by hydrophilic interaction liquid chromatography (HILIC) followed by positive-ion electrospray ionization mass spectrometry (ESI-MS) using a single internal lipid standard to which all class specific response factors (RFs) are related to. The developed method enables the nontargeted quantitation of lipid classes and molecules inside these classes in contrast to the conventional targeted quantitation, which is based on predefined selected reaction monitoring (SRM) transitions for selected lipids only. In the nontargeted quantitation method described here, concentrations of lipid classes are obtained by the peak integration in HILIC chromatograms multiplied by their RFs related to the single internal standard (i.e., sphingosyl PE, d17:1/12:0) used as common reference for all polar lipid classes. The accuracy, reproducibility and robustness of the method have been checked by various means: (1) the comparison with conventional lipidomic quantitation using SRM scans on a triple quadrupole (QqQ) mass analyzer, (2) (31)P nuclear magnetic resonance (NMR) quantitation of the total lipid extract, (3) method robustness test using subsequent measurements by three different persons, (4) method transfer to different HPLC/MS systems using different chromatographic conditions, and (5) comparison with previously published results for identical samples, especially human reference plasma from the National Institute of Standards and Technology (NIST human plasma). Results on human plasma, egg yolk and porcine liver extracts are presented and discussed.
Quantitative angle-insensitive flow measurement using relative standard deviation OCT.
Zhu, Jiang; Zhang, Buyun; Qi, Li; Wang, Ling; Yang, Qiang; Zhu, Zhuqing; Huo, Tiancheng; Chen, Zhongping
2017-10-30
Incorporating different data processing methods, optical coherence tomography (OCT) has the ability for high-resolution angiography and quantitative flow velocity measurements. However, OCT angiography cannot provide quantitative information of flow velocities, and the velocity measurement based on Doppler OCT requires the determination of Doppler angles, which is a challenge in a complex vascular network. In this study, we report on a relative standard deviation OCT (RSD-OCT) method which provides both vascular network mapping and quantitative information for flow velocities within a wide range of Doppler angles. The RSD values are angle-insensitive within a wide range of angles, and a nearly linear relationship was found between the RSD values and the flow velocities. The RSD-OCT measurement in a rat cortex shows that it can quantify the blood flow velocities as well as map the vascular network in vivo .
Quantitative angle-insensitive flow measurement using relative standard deviation OCT
NASA Astrophysics Data System (ADS)
Zhu, Jiang; Zhang, Buyun; Qi, Li; Wang, Ling; Yang, Qiang; Zhu, Zhuqing; Huo, Tiancheng; Chen, Zhongping
2017-10-01
Incorporating different data processing methods, optical coherence tomography (OCT) has the ability for high-resolution angiography and quantitative flow velocity measurements. However, OCT angiography cannot provide quantitative information of flow velocities, and the velocity measurement based on Doppler OCT requires the determination of Doppler angles, which is a challenge in a complex vascular network. In this study, we report on a relative standard deviation OCT (RSD-OCT) method which provides both vascular network mapping and quantitative information for flow velocities within a wide range of Doppler angles. The RSD values are angle-insensitive within a wide range of angles, and a nearly linear relationship was found between the RSD values and the flow velocities. The RSD-OCT measurement in a rat cortex shows that it can quantify the blood flow velocities as well as map the vascular network in vivo.
Target volume and artifact evaluation of a new data-driven 4D CT.
Martin, Rachael; Pan, Tinsu
Four-dimensional computed tomography (4D CT) is often used to define the internal gross target volume (IGTV) for radiation therapy of lung cancer. Traditionally, this technique requires the use of an external motion surrogate; however, a new image, data-driven 4D CT, has become available. This study aims to describe this data-driven 4D CT and compare target contours created with it to those created using standard 4D CT. Cine CT data of 35 patients undergoing stereotactic body radiation therapy were collected and sorted into phases using standard and data-driven 4D CT. IGTV contours were drawn using a semiautomated method on maximum intensity projection images of both 4D CT methods. Errors resulting from reproducibility of the method were characterized. A comparison of phase image artifacts was made using a normalized cross-correlation method that assigned a score from +1 (data-driven "better") to -1 (standard "better"). The volume difference between the data-driven and standard IGTVs was not significant (data driven was 2.1 ± 1.0% smaller, P = .08). The Dice similarity coefficient showed good similarity between the contours (0.949 ± 0.006). The mean surface separation was 0.4 ± 0.1 mm and the Hausdorff distance was 3.1 ± 0.4 mm. An average artifact score of +0.37 indicated that the data-driven method had significantly fewer and/or less severe artifacts than the standard method (P = 1.5 × 10 -5 for difference from 0). On average, the difference between IGTVs derived from data-driven and standard 4D CT was not clinically relevant or statistically significant, suggesting data-driven 4D CT can be used in place of standard 4D CT without adjustments to IGTVs. The relatively large differences in some patients were usually attributed to limitations in automatic contouring or differences in artifacts. Artifact reduction and setup simplicity suggest a clinical advantage to data-driven 4D CT. Published by Elsevier Inc.
NASA Astrophysics Data System (ADS)
Bouldin, J.
2010-12-01
In the reconstruction of past climates from tree rings multi-decadal to multi-centennial periods, one longstanding problem is the confounding of the natural biological growth trend of the tree with any existing long term trends in the climate. No existing analytical method is capable of resolving these two change components, so it remains unclear how accurate existing ring series standardizations are, and by implication, climate reconstructions based upon them. For example, dendrochronological at the ITRDB are typically standardized by detrending, at each site, each individual tree core, using a relatively stiff deterministic function such as a negative exponential curve or smoothing spline. Another approach, referred to as RCS (Regional Curve Standardization) attempts to solve some problems of the individual series detrending, by constructing a single growth curve from the aggregated cambial ages of the rings of the cores at a site (or collection of sites). This curve is presumed to represent the “ideal” or expected growth of the trees from which it is derived. Although an improvement in some respects, this method will be degraded in direct proportion to the lack of a mixture of tree sizes or ages throughout the span of the chronology. I present a new method of removing the biological curve from tree ring series, such that temporal changes better represent the environmental variation captured by the tree rings. The method institutes several new approaches, such as the correction for the estimated number of missed rings near the pith, and the use of tree size and ring area relationships instead of the traditional tree ages and ring widths. The most important innovation is a careful extraction of the existing information on the relationship between tree size (basal area) and ring area that exists within each single year of the chronology. This information is, by definition, not contaminated by temporal climatic changes, and so when removed, leaves the climatically caused, and random error components of the chronology. A sophisticated algorithm, based on pair-wise ring comparisons in which tree size is standardized both within and between years, forms the basis of the method. Evaluations of the method are underway with both simulated and actual (ITRDB) data, to evaluate the potentials and drawbacks of the method relative to existing methods. The ITRDB test data consists of a set of about 50 primarily high elevation sites from across western North America. Most of these sites show a pronounced 20th Century warming relative to earlier centuries, in accordance with current understanding, albeit at a non-global scale. A relative minority show cooling, occasionally strongly. Current and future work emphasizes evaluation of the method with varying, simulated data, and more thorough empirical evaluations of the method in situations where the type, and intensity, of the primary environmentally limiting factor varies (e.g temperature versus soil moisture limited sites).
NASA Astrophysics Data System (ADS)
Mai, W.; Zhang, J.-F.; Zhao, X.-M.; Li, Z.; Xu, Z.-W.
2017-11-01
Wastewater from the dye industry is typically analyzed using a standard method for measurement of chemical oxygen demand (COD) or by a single-wavelength spectroscopic method. To overcome the disadvantages of these methods, ultraviolet-visible (UV-Vis) spectroscopy was combined with principal component regression (PCR) and partial least squares regression (PLSR) in this study. Unlike the standard method, this method does not require digestion of the samples for preparation. Experiments showed that the PLSR model offered high prediction performance for COD, with a mean relative error of about 5% for two dyes. This error is similar to that obtained with the standard method. In this study, the precision of the PLSR model decreased with the number of dye compounds present. It is likely that multiple models will be required in reality, and the complexity of a COD monitoring system would be greatly reduced if the PLSR model is used because it can include several dyes. UV-Vis spectroscopy with PLSR successfully enhanced the performance of COD prediction for dye wastewater and showed good potential for application in on-line water quality monitoring.
Reviving common standards in point-count surveys for broad inference across studies
Matsuoka, Steven M.; Mahon, C. Lisa; Handel, Colleen M.; Solymos, Peter; Bayne, Erin M.; Fontaine, Patricia C.; Ralph, C.J.
2014-01-01
We revisit the common standards recommended by Ralph et al. (1993, 1995a) for conducting point-count surveys to assess the relative abundance of landbirds breeding in North America. The standards originated from discussions among ornithologists in 1991 and were developed so that point-count survey data could be broadly compared and jointly analyzed by national data centers with the goals of monitoring populations and managing habitat. Twenty years later, we revisit these standards because (1) they have not been universally followed and (2) new methods allow estimation of absolute abundance from point counts, but these methods generally require data beyond the original standards to account for imperfect detection. Lack of standardization and the complications it introduces for analysis become apparent from aggregated data. For example, only 3% of 196,000 point counts conducted during the period 1992-2011 across Alaska and Canada followed the standards recommended for the count period and count radius. Ten-minute, unlimited-count-radius surveys increased the number of birds detected by >300% over 3-minute, 50-m-radius surveys. This effect size, which could be eliminated by standardized sampling, was ≥10 times the published effect sizes of observers, time of day, and date of the surveys. We suggest that the recommendations by Ralph et al. (1995a) continue to form the common standards when conducting point counts. This protocol is inexpensive and easy to follow but still allows the surveys to be adjusted for detection probabilities. Investigators might optionally collect additional information so that they can analyze their data with more flexible forms of removal and time-of-detection models, distance sampling, multiple-observer methods, repeated counts, or combinations of these methods. Maintaining the common standards as a base protocol, even as these study-specific modifications are added, will maximize the value of point-count data, allowing compilation and analysis by regional and national data centers.
AGARD standard aeroelastic configurations for dynamic response. 1: Wing 445.6
NASA Technical Reports Server (NTRS)
Yates, E. Carson, Jr.
1988-01-01
This report contains experimental flutter data for the AGARD 3-D swept tapered standard configuration Wing 445.6, along with related descriptive data of the model properties required for comparative flutter calculations. As part of a cooperative AGARD-SMP program, guided by the Sub-Committee on Aeroelasticity, this standard configuration may serve as a common basis for comparison of calculated and measured aeroelastic behavior. These comparisons will promote a better understanding of the assumptions, approximations and limitations underlying the various aerodynamic methods applied, thus pointing the way to further improvements.
The Economics of Alternative School Feeding Systems.
ERIC Educational Resources Information Center
Payne, Norman E.; And Others
This study, based on data for the 1970-71 school year, develops a uniform method for comparing costs of alternative school feeding systems. The study attempted to determine relative costs of providing meals under alternative production and distribution systems, establish standards relating to food costs and labor efficiency that could be used in…
Blending and nudging in fluid dynamics: some simple observations
NASA Astrophysics Data System (ADS)
Germano, M.
2017-10-01
Blending and nudging methods have been recently applied in fluid dynamics, particularly regarding the assimilation of experimental data into the computations. In the paper we formally derive the differential equation associated to blending and compare it to the standard nudging equation. Some simple considerations related to these techniques and their mutual relations are exposed.
Alternative Confidence Interval Methods Used in the Diagnostic Accuracy Studies
Gülhan, Orekıcı Temel
2016-01-01
Background/Aim. It is necessary to decide whether the newly improved methods are better than the standard or reference test or not. To decide whether the new diagnostics test is better than the gold standard test/imperfect standard test, the differences of estimated sensitivity/specificity are calculated with the help of information obtained from samples. However, to generalize this value to the population, it should be given with the confidence intervals. The aim of this study is to evaluate the confidence interval methods developed for the differences between the two dependent sensitivity/specificity values on a clinical application. Materials and Methods. In this study, confidence interval methods like Asymptotic Intervals, Conditional Intervals, Unconditional Interval, Score Intervals, and Nonparametric Methods Based on Relative Effects Intervals are used. Besides, as clinical application, data used in diagnostics study by Dickel et al. (2010) has been taken as a sample. Results. The results belonging to the alternative confidence interval methods for Nickel Sulfate, Potassium Dichromate, and Lanolin Alcohol are given as a table. Conclusion. While preferring the confidence interval methods, the researchers have to consider whether the case to be compared is single ratio or dependent binary ratio differences, the correlation coefficient between the rates in two dependent ratios and the sample sizes. PMID:27478491
Alternative Confidence Interval Methods Used in the Diagnostic Accuracy Studies.
Erdoğan, Semra; Gülhan, Orekıcı Temel
2016-01-01
Background/Aim. It is necessary to decide whether the newly improved methods are better than the standard or reference test or not. To decide whether the new diagnostics test is better than the gold standard test/imperfect standard test, the differences of estimated sensitivity/specificity are calculated with the help of information obtained from samples. However, to generalize this value to the population, it should be given with the confidence intervals. The aim of this study is to evaluate the confidence interval methods developed for the differences between the two dependent sensitivity/specificity values on a clinical application. Materials and Methods. In this study, confidence interval methods like Asymptotic Intervals, Conditional Intervals, Unconditional Interval, Score Intervals, and Nonparametric Methods Based on Relative Effects Intervals are used. Besides, as clinical application, data used in diagnostics study by Dickel et al. (2010) has been taken as a sample. Results. The results belonging to the alternative confidence interval methods for Nickel Sulfate, Potassium Dichromate, and Lanolin Alcohol are given as a table. Conclusion. While preferring the confidence interval methods, the researchers have to consider whether the case to be compared is single ratio or dependent binary ratio differences, the correlation coefficient between the rates in two dependent ratios and the sample sizes.
Glysson, G. Douglas; Skinner, John V.
1991-01-01
In the late 1950's, intense demands for water and growing concerns about declines in the quality of water generated the need for more water-resources data. About thirty Federal agencies, hundreds of State, county and local agencies, and many private organizations had been collecting water data. However, because of differences in procedures and equipment, many of the data bases were incompatible. In 1964, as a step toward establishing more uniformity, the Bureau of the Budget (now the Office of Management and Budget, OMB) issued 'Circular A-67' which presented guidelines for collecting water data and also served as a catalyst for creating the Office of Water Data Coordination (OWDC) within the U.S. Geological Survey. This paper discusses past, present, and future aspects of the relation between methods in the National Handbook and standards published by ASTM (American Society for Testing and Materials) Committee D-19 on Water's Subcommittee D-19.07 on Sediment, Geomorphology, and Open Channel Flow. The discussion also covers historical aspects of standards - development work jointly conducted by OWDC and ASTM.
Huang, Shi; MacKinnon, David P.; Perrino, Tatiana; Gallo, Carlos; Cruden, Gracelyn; Brown, C Hendricks
2016-01-01
Mediation analysis often requires larger sample sizes than main effect analysis to achieve the same statistical power. Combining results across similar trials may be the only practical option for increasing statistical power for mediation analysis in some situations. In this paper, we propose a method to estimate: 1) marginal means for mediation path a, the relation of the independent variable to the mediator; 2) marginal means for path b, the relation of the mediator to the outcome, across multiple trials; and 3) the between-trial level variance-covariance matrix based on a bivariate normal distribution. We present the statistical theory and an R computer program to combine regression coefficients from multiple trials to estimate a combined mediated effect and confidence interval under a random effects model. Values of coefficients a and b, along with their standard errors from each trial are the input for the method. This marginal likelihood based approach with Monte Carlo confidence intervals provides more accurate inference than the standard meta-analytic approach. We discuss computational issues, apply the method to two real-data examples and make recommendations for the use of the method in different settings. PMID:28239330
Koch, Iris; Reimer, Kenneth J; Bakker, Martine I; Basta, Nicholas T; Cave, Mark R; Denys, Sébastien; Dodd, Matt; Hale, Beverly A; Irwin, Rob; Lowney, Yvette W; Moore, Margo M; Paquin, Viviane; Rasmussen, Pat E; Repaso-Subang, Theresa; Stephenson, Gladys L; Siciliano, Steven D; Wragg, Joanna; Zagury, Gerald J
2013-01-01
Bioaccessibility is a measurement of a substance's solubility in the human gastro-intestinal system, and is often used in the risk assessment of soils. The present study was designed to determine the variability among laboratories using different methods to measure the bioaccessibility of 24 inorganic contaminants in one standardized soil sample, the standard reference material NIST 2710. Fourteen laboratories used a total of 17 bioaccessibility extraction methods. The variability between methods was assessed by calculating the reproducibility relative standard deviations (RSDs), where reproducibility is the sum of within-laboratory and between-laboratory variability. Whereas within-laboratory repeatability was usually better than (<) 15% for most elements, reproducibility RSDs were much higher, indicating more variability, although for many elements they were comparable to typical uncertainties (e.g., 30% in commercial laboratories). For five trace elements of interest, reproducibility RSDs were: arsenic (As), 22-44%; cadmium (Cd), 11-41%; Cu, 15-30%; lead (Pb), 45-83%; and Zn, 18-56%. Only one method variable, pH, was found to correlate significantly with bioaccessibility for aluminum (Al), Cd, copper (Cu), manganese (Mn), Pb and zinc (Zn) but other method variables could not be examined systematically because of the study design. When bioaccessibility results were directly compared with bioavailability results for As (swine and mouse) and Pb (swine), four methods returned results within uncertainty ranges for both elements: two that were defined as simpler (gastric phase only, limited chemicals) and two were more complex (gastric + intestinal phases, with a mixture of chemicals).
Siddiqui, Mohammad Jamshed Ahmad; Ismail, Zhari; Saidan, Noor Hafizoh
2011-01-01
Background: Vinca rosea (Apocynaceae) is one of the most important and high value medicinal plants known for its anticancer alkaloids. It is the iota of the isolated secondary metabolites used in chemotherapy to treat diverse cancers. Several high performance liquid chromatography (HPLC) methods have been developed to quantify the active alkaloids in the plant. However, this method may serve the purpose in quantification of V. rosea plant extracts in totality. Objective: To develop and validate the reverse phase (RP)-HPLC method for simultaneous determination of secondary metabolites, namely alkaloids from V. rosea plant extracts. Materials and Methods: The quantitative determination was conducted by RP-HPLC equipped with ultraviolet detector. Optimal separation was achieved by isocratic elution with mobile phase consisting of methanol:acetonitrile:ammonium acetate buffer (25 mM) with 0.1% triethylamine (15:45:40 v/v) on a column (Zorbax Eclipse plus C18, 250 mm % 4.6 mm; 5 μm). The standard markers (vindoline, vincristine, catharanthine, and vinblastine) were identified by retention time and co-injected with reference standard and quantified by external standard method at 297 nm. Results: The precision of the method was confirmed by the relative standard deviation (R.S.D.), which was lower than 2.68%. The recoveries were in the range of 98.09%-108%. The limits of detection (LOD) for each marker alkaloids were lower than 0.20 μg. Different parts of the V. rosea extracts shows different concentrations of markers, flower samples were high in vinblastine content, while methanol extract from the leaves contains all the four alkaloids in good yield, and there is no significant presence of markers in water extracts. Conclusion: HPLC method established is appropriate for the standardization and quality assurance of V. rosea plant extracts. PMID:21716929
Validation of PCR methods for quantitation of genetically modified plants in food.
Hübner, P; Waiblinger, H U; Pietsch, K; Brodmann, P
2001-01-01
For enforcement of the recently introduced labeling threshold for genetically modified organisms (GMOs) in food ingredients, quantitative detection methods such as quantitative competitive (QC-PCR) and real-time PCR are applied by official food control laboratories. The experiences of 3 European food control laboratories in validating such methods were compared to describe realistic performance characteristics of quantitative PCR detection methods. The limit of quantitation (LOQ) of GMO-specific, real-time PCR was experimentally determined to reach 30-50 target molecules, which is close to theoretical prediction. Starting PCR with 200 ng genomic plant DNA, the LOQ depends primarily on the genome size of the target plant and ranges from 0.02% for rice to 0.7% for wheat. The precision of quantitative PCR detection methods, expressed as relative standard deviation (RSD), varied from 10 to 30%. Using Bt176 corn containing test samples and applying Bt176 specific QC-PCR, mean values deviated from true values by -7to 18%, with an average of 2+/-10%. Ruggedness of real-time PCR detection methods was assessed in an interlaboratory study analyzing commercial, homogeneous food samples. Roundup Ready soybean DNA contents were determined in the range of 0.3 to 36%, relative to soybean DNA, with RSDs of about 25%. Taking the precision of quantitative PCR detection methods into account, suitable sample plans and sample sizes for GMO analysis are suggested. Because quantitative GMO detection methods measure GMO contents of samples in relation to reference material (calibrants), high priority must be given to international agreements and standardization on certified reference materials.
Guo, Sen; Cui, Xueqin; Jiang, Mi; Bai, Lu; Tian, Xiao; Guo, Tiantian; Liu, Qingchao; Zhang, Li; Ho, Chi-Tang; Bai, Naisheng
2017-04-01
Rabdosia rubescens is a healthy herbal tea and well-known Chinese medicinal herb. To evaluate the quality of R. rubescens from China, a high performance liquid chromatography method with dual-wavelength detection was developed and validated. The method was successfully applied for the simultaneous characterization and quantification of 17 main constituents from four different cultivation regions in China. Under optimal conditions, analysis was performed on a Luna C-18 column and gradient elution with a solvent system of acetonitrile and 0.5% (v/v) acetic acid-water at a flow rate of 1.0 mL/min and wavelength of 220 nm and 280 nm. All standard calibration curves exhibited good linearity (r 2 > 0.9992) within the test ranges. The precision was evaluated by intraday and interday tests, which revealed relative standard deviation values within the ranges of 0.57-2.35% and 0.52-3.40%, respectively. The recoveries were in the range of 96.37-101.66%. The relative standard deviation values for stability and repeatability were < 5%. The contents of some compounds were low and varied with different cultivars. The proposed method could serve as a prerequisite for quality control of R. rubescens materials and products. Copyright © 2016. Published by Elsevier B.V.
Improving data quality in the linked open data: a survey
NASA Astrophysics Data System (ADS)
Hadhiatma, A.
2018-03-01
The Linked Open Data (LOD) is “web of data”, a different paradigm from “web of document” commonly used today. However, the huge LOD still suffers from data quality problems such as completeness, consistency, and accuracy. Data quality problems relate to designing effective methods both to manage and to retrieve information at various data quality levels. Based on review from papers and journals, addressing data quality requires some standards functioning to (1) identification of data quality problems, (2) assessment of data quality for a given context, and (3) correction of data quality problems. However, mostly the methods and strategies dealing with the LOD data quality were not as an integrative approach. Hence, based on those standards and an integrative approach, there are opportunities to improve the LOD data quality in the term of incompleteness, inaccuracy and inconsistency, considering to its schema and ontology, namely ontology refinement. Moreover, the term of the ontology refinement means that it copes not only to improve data quality but also to enrich the LOD. Therefore, it needs (1) a standard for data quality assessment and evaluation which is more appropriate to the LOD; (2) a framework of methods based on statistical relational learning that can improve the correction of data quality problems as well as enrich the LOD.
NASA Astrophysics Data System (ADS)
Belov, S. Yu.; Belova, I. N.
2017-11-01
Monitoring of the earth's surface by remote sensing in the short-wave band can provide quick identification of some characteristics of natural systems. This band range allows one to diagnose subsurface aspects of the earth, as the scattering parameter is affected by irregularities in the dielectric permittivity of subsurface structures. This method based on the organization of the monitoring probe may detect changes in these environments, for example, to assess seismic hazard, hazardous natural phenomena such as earthquakes, as well as some man-made hazards and etc. The problem of measuring and accounting for the scattering power of the earth's surface in the short-range of radio waves is important for a number of purposes, such as diagnosing properties of the medium, which is of interest for geological, environmental studies. In this paper, we propose a new method for estimating the parameters of incoherent signal/noise ratio. The paper presents the results of comparison of the measurement method from the point of view of their admissible relative analytical errors. The new method is suggested. Analysis of analytical error of estimation of this parameter allowed to recommend new method instead of standard method. A comparative analysis and shows that the analytical (relative) accuracy of the determination of this parameter new method on the order exceeds the widely-used standard method.
Method of Reproduction of the Luminous Flux of the LED Light Sources by a Spherical Photometer
NASA Astrophysics Data System (ADS)
Huriev, M.; Neyezhmakov, P.
2018-02-01
In connection with transition to energy-efficient temporally stable light-emitting diodes (LEDs) lighting, a problem of ensuring the traceability of results of measurement of characteristics of light sources arises. The problem is related to existing measurement standards of luminous flux based on spherical photometers optimized for the reference incandescent lamps with a relative spectral characteristic different from the spectrum of the LEDs. We propose a method for reproduction of the luminous flux, which solves this problem.
Okuma, Kazu; Yamochi, Tadanori; Sato, Tomoo; Sasaki, Daisuke; Hasegawa, Hiroo; Umeki, Kazumi; Kubota, Ryuji; Sobata, Rieko; Matsumoto, Chieko; Kaneko, Noriaki; Naruse, Isao; Yamagishi, Makoto; Nakashima, Makoto; Momose, Haruka; Araki, Kumiko; Mizukami, Takuo; Mizusawa, Saeko; Okada, Yoshiaki; Ochiai, Masaki; Utsunomiya, Atae; Koh, Ki-Ryang; Ogata, Masao; Nosaka, Kisato; Uchimaru, Kaoru; Iwanaga, Masako; Sagara, Yasuko; Yamano, Yoshihisa; Satake, Masahiro; Okayama, Akihiko; Mochizuki, Manabu; Izumo, Shuji; Saito, Shigeru; Itabashi, Kazuo; Kamihira, Shimeru; Yamaguchi, Kazunari; Watanabe, Toshiki
2015-01-01
Quantitative PCR (qPCR) analysis of human T-cell leukemia virus type 1 (HTLV-1) was used to assess the amount of HTLV-1 provirus DNA integrated into the genomic DNA of host blood cells. Accumulating evidence indicates that a high proviral load is one of the risk factors for the development of adult T-cell leukemia/lymphoma and HTLV-1-associated myelopathy/tropical spastic paraparesis. However, interlaboratory variability in qPCR results makes it difficult to assess the differences in reported proviral loads between laboratories. To remedy this situation, we attempted to minimize discrepancies between laboratories through standardization of HTLV-1 qPCR in a collaborative study. TL-Om1 cells that harbor the HTLV-1 provirus were serially diluted with peripheral blood mononuclear cells to prepare a candidate standard. By statistically evaluating the proviral loads of the standard and those determined using in-house qPCR methods at each laboratory, we determined the relative ratios of the measured values in the laboratories to the theoretical values of the TL-Om1 standard. The relative ratios of the laboratories ranged from 0.84 to 4.45. Next, we corrected the proviral loads of the clinical samples from HTLV-1 carriers using the relative ratio. As expected, the overall differences between the laboratories were reduced by half, from 7.4-fold to 3.8-fold on average, after applying the correction. HTLV-1 qPCR can be standardized using TL-Om1 cells as a standard and by determining the relative ratio of the measured to the theoretical standard values in each laboratory. PMID:26292315
Kuramitsu, Madoka; Okuma, Kazu; Yamochi, Tadanori; Sato, Tomoo; Sasaki, Daisuke; Hasegawa, Hiroo; Umeki, Kazumi; Kubota, Ryuji; Sobata, Rieko; Matsumoto, Chieko; Kaneko, Noriaki; Naruse, Isao; Yamagishi, Makoto; Nakashima, Makoto; Momose, Haruka; Araki, Kumiko; Mizukami, Takuo; Mizusawa, Saeko; Okada, Yoshiaki; Ochiai, Masaki; Utsunomiya, Atae; Koh, Ki-Ryang; Ogata, Masao; Nosaka, Kisato; Uchimaru, Kaoru; Iwanaga, Masako; Sagara, Yasuko; Yamano, Yoshihisa; Satake, Masahiro; Okayama, Akihiko; Mochizuki, Manabu; Izumo, Shuji; Saito, Shigeru; Itabashi, Kazuo; Kamihira, Shimeru; Yamaguchi, Kazunari; Watanabe, Toshiki; Hamaguchi, Isao
2015-11-01
Quantitative PCR (qPCR) analysis of human T-cell leukemia virus type 1 (HTLV-1) was used to assess the amount of HTLV-1 provirus DNA integrated into the genomic DNA of host blood cells. Accumulating evidence indicates that a high proviral load is one of the risk factors for the development of adult T-cell leukemia/lymphoma and HTLV-1-associated myelopathy/tropical spastic paraparesis. However, interlaboratory variability in qPCR results makes it difficult to assess the differences in reported proviral loads between laboratories. To remedy this situation, we attempted to minimize discrepancies between laboratories through standardization of HTLV-1 qPCR in a collaborative study. TL-Om1 cells that harbor the HTLV-1 provirus were serially diluted with peripheral blood mononuclear cells to prepare a candidate standard. By statistically evaluating the proviral loads of the standard and those determined using in-house qPCR methods at each laboratory, we determined the relative ratios of the measured values in the laboratories to the theoretical values of the TL-Om1 standard. The relative ratios of the laboratories ranged from 0.84 to 4.45. Next, we corrected the proviral loads of the clinical samples from HTLV-1 carriers using the relative ratio. As expected, the overall differences between the laboratories were reduced by half, from 7.4-fold to 3.8-fold on average, after applying the correction. HTLV-1 qPCR can be standardized using TL-Om1 cells as a standard and by determining the relative ratio of the measured to the theoretical standard values in each laboratory. Copyright © 2015, American Society for Microbiology. All Rights Reserved.
Zhang, Dan; Wang, Xiaolin; Liu, Man; Zhang, Lina; Deng, Ming; Liu, Huichen
2015-01-01
A rapid, sensitive and accurate ICP-MS method using alternate analyte-free matrix for calibration standards preparation and a rapid direct dilution procedure for sample preparation was developed and validated for the quantification of exogenous strontium (Sr) from the drug in human serum. Serum was prepared by direct dilution (1:29, v/v) in an acidic solution consisting of nitric acid (0.1%) and germanium (Ge) added as internal standard (IS), to obtain simple and high-throughput preparation procedure with minimized matrix effect, and good repeatability. ICP-MS analysis was performed using collision cell technology (CCT) mode. Alternate matrix method by using distilled water as an alternate analyte-free matrix for the preparation of calibration standards (CS) was used to avoid the influence of endogenous Sr in serum on the quantification. The method was validated in terms of selectivity, carry-over, matrix effects, lower limit of quantification (LLOQ), linearity, precision and accuracy, and stability. Instrumental linearity was verified in the range of 1.00-500ng/mL, corresponding to a concentration range of 0.0300-15.0μg/mL in 50μL sample of serum matrix and alternate matrix. Intra- and inter-day precision as relative standard deviation (RSD) were less than 8.0% and accuracy as relative error (RE) was within ±3.0%. The method allowed a high sample throughput, and was sensitive and accurate enough for a pilot bioequivalence study in healthy male Chinese subjects following single oral administration of two strontium ranelate formulations containing 2g strontium ranelate. Copyright © 2014 Elsevier GmbH. All rights reserved.
Xie, Wei-Qi; Chai, Xin-Sheng
2016-10-14
This work reports on a novel method for the determination of isocyanate groups in the related organic intermediates by a reaction-based headspace gas chromatography. The method is based on measuring the CO 2 formed from the reaction between the isocyanate groups in the organic intermediates and water in a closed headspace sample vial at 45°C for 20min. The results showed that the method has a good precision and accuracy, in which the relative standard deviation in the repeatability measurement was 5.26%, and the relative differences between the data obtained by the HS-GC method and the reference back-titration method were within 9.42%. The present method is simple and efficient and is particularly suitable to be used for determining the isocyanate groups in the batch sample analysis. Copyright © 2016 Elsevier B.V. All rights reserved.
[Detection of KRAS mutation in colorectal cancer patients' cfDNA with droplet digital PCR].
Luo, Yuwen; Li, Yao
2018-03-25
This study aims to develop a new method for the detection of KRAS mutations related to colorectal cancer in cfDNA, and to evaluate the sensitivity and accuracy of the detection. We designed a method of cfDNA based KRAS detection by droplets digital PCR (ddPCR). The theoretical performance of the method is evaluated by reference standard and compared to the ARMS PCR method. Two methods, ddPCR and qPCR, were successfully established to detect KRAS wild type and 7 mutants. Both methods were validated using plasmid standards and actual samples. The results were evaluated by false positive rate, linearity, and limit of detection. Finally, 52 plasma cfDNA samples from patients and 20 samples from healthy people were tested, the clinical sensitivity is 97.64%, clinical specificity is 81.43%. ddPCR method shows higher performance than qPCR. The LOD of ddPCR method reached single digits of cfDNA copies, it can detect as low as 0.01% to 0.04% mutation abundance.
Liang, M H
2000-09-01
Although widely used and reported in research for the evaluation of groups, measures of health status and health-related quality of life have had little application in clinical practice for the assessment of individual patients. One of the principal barriers is the demonstration that these measures add clinically significant information to measures of function or symptoms alone. Here, we review the methods for evaluation of construct validity in longitudinal studies and make recommendations for nomenclature, reporting of study results, and future research agenda. Analytical review. The terms "sensitivity" and "responsiveness" have been used interchangeably, and there are few studies that evaluate the extent to which health status or health-related quality-of life measures capture clinically important changes ("responsiveness"). Current methods of evaluating responsiveness are not standardized or evaluated. Approaches for the assessment of a clinically significant or meaningful change are described; rather than normative information, however, standardized transition questions are proposed. They would be reported routinely and as separate axes of description to capture individual perceptions. Research in methods to assess the subject's evaluation of the importance and magnitude of a measured change are critical if health status and health-related quality-of-life measures are to have an impact on patient care.
Uniform-related infection control practices of dental students
Aljohani, Yazan; Almutadares, Mohammed; Alfaifi, Khalid; El Madhoun, Mona; Albahiti, Maysoon H; Al-Hazmi, Nadia
2017-01-01
Background Uniform-related infection control practices are sometimes overlooked and underemphasized. In Saudi Arabia, personal protective equipment must meet global standards for infection control, but the country’s Islamic legislature also needs to be taken into account. Aim To assess uniform-related infection control practices of a group of dental students in a dental school in Saudi Arabia and compare the results with existing literature related to cross-contamination through uniforms in the dental field. Method A questionnaire was formulated and distributed to dental students at King Abdulaziz University Faculty of Dentistry in Jeddah, Saudi Arabia, which queried the students about their uniform-related infection control practices and their methods and frequency of laundering and sanitizing their uniforms, footwear, and name tags. Results There is a significant difference between genders with regard to daily uniform habits. The frequency of uniform washing was below the standard and almost 30% of students were not aware of how their uniforms are washed. Added to this, there is no consensus on a unified uniform for male and female students. Conclusion Information on preventing cross-contamination through wearing uniforms must be supplied, reinforced, and emphasized while taking into consideration the cultural needs of the Saudi society. PMID:28490894
Evaluation of MLACF based calculated attenuation brain PET imaging for FDG patient studies
NASA Astrophysics Data System (ADS)
Bal, Harshali; Panin, Vladimir Y.; Platsch, Guenther; Defrise, Michel; Hayden, Charles; Hutton, Chloe; Serrano, Benjamin; Paulmier, Benoit; Casey, Michael E.
2017-04-01
Calculating attenuation correction for brain PET imaging rather than using CT presents opportunities for low radiation dose applications such as pediatric imaging and serial scans to monitor disease progression. Our goal is to evaluate the iterative time-of-flight based maximum-likelihood activity and attenuation correction factors estimation (MLACF) method for clinical FDG brain PET imaging. FDG PET/CT brain studies were performed in 57 patients using the Biograph mCT (Siemens) four-ring scanner. The time-of-flight PET sinograms were acquired using the standard clinical protocol consisting of a CT scan followed by 10 min of single-bed PET acquisition. Images were reconstructed using CT-based attenuation correction (CTAC) and used as a gold standard for comparison. Two methods were compared with respect to CTAC: a calculated brain attenuation correction (CBAC) and MLACF based PET reconstruction. Plane-by-plane scaling was performed for MLACF images in order to fix the variable axial scaling observed. The noise structure of the MLACF images was different compared to those obtained using CTAC and the reconstruction required a higher number of iterations to obtain comparable image quality. To analyze the pooled data, each dataset was registered to a standard template and standard regions of interest were extracted. An SUVr analysis of the brain regions of interest showed that CBAC and MLACF were each well correlated with CTAC SUVrs. A plane-by-plane error analysis indicated that there were local differences for both CBAC and MLACF images with respect to CTAC. Mean relative error in the standard regions of interest was less than 5% for both methods and the mean absolute relative errors for both methods were similar (3.4% ± 3.1% for CBAC and 3.5% ± 3.1% for MLACF). However, the MLACF method recovered activity adjoining the frontal sinus regions more accurately than CBAC method. The use of plane-by-plane scaling of MLACF images was found to be a crucial step in order to obtain improved activity estimates. Presence of local errors in both MLACF and CBAC based reconstructions would require the use of a normal database for clinical assessment. However, further work is required in order to assess the clinical advantage of MLACF over CBAC based method.
Park, Su-Jin; Kim, Nam Kyun; Kim, Jung Ok; Yoo, Byung Won; Sul, Jun Hee
2010-01-01
Background and Objectives The rigid coupling between the delivery wire and the right atrial disk has been occasionally encountered during transcatheter closure of atrial septal defect (ASD). Therefore the device frequently makes a perpendicular angle, and the leading edge of left atrial disk slips through the defect and prolapses into right atrium (RA) before it is properly placed in the septum. The purpose of this study is to investigate relating factors to the need of technical modification in transcatheter closure of large ASD and to evaluate relevant morphologic characteristics of atrial septal rim in this situation. Subjects and Methods From July, 2003 to May, 2007, 312 patients underwent transcatheter occlusion of ASD with Amplatzer Septal Occluder® (ASO, AGA medical corporation, Golden Valley, MN, USA) at Yonsei Cardiovascular Center and among them 109 patients had large ASD (≥25 mm) and these patients were enrolled in our study. Patients were divided into two groups according to the deploying methods of the device (Group I: standard method, Group II: modified methods). Assessments of the defects and its surrounding rims were made by echocardiography. Results There were no differences between 2 groups in age, body weight and height except for balloon-stretched diameter (stop-flow technique) and device size. Group II patients with modified methods showed larger balloon-stretched diameter and device size than group I patients with standard method. The mean length of anterosuperior (AS) rim in group II was significantly shorter than group I (p<0.05). As the size of the device used in procedure increased, there was a trend towards increase in the need of modified methods. Conclusion This study shows that AS rim deficiency and the size of ASD may be the relating factors to the need of technical modification in transcatheter closure of ASD. Therefore, when the initial try with standard method is not successful in large ASD with deficient AS rim, we suggest that changing strategy of implantation may save time and efforts and possibly reduce the risk of complications associated with prolonged procedure. PMID:20421960
Tsukahara, Keita; Takabatake, Reona; Masubuchi, Tomoko; Futo, Satoshi; Minegishi, Yasutaka; Noguchi, Akio; Kondo, Kazunari; Nishimaki-Mogami, Tomoko; Kurashima, Takeyo; Mano, Junichi; Kitta, Kazumi
2016-01-01
A real-time PCR-based analytical method was developed for the event-specific quantification of a genetically modified (GM) soybean event, MON87701. First, a standard plasmid for MON87701 quantification was constructed. The conversion factor (C f ) required to calculate the amount of genetically modified organism (GMO) was experimentally determined for a real-time PCR instrument. The determined C f for the real-time PCR instrument was 1.24. For the evaluation of the developed method, a blind test was carried out in an inter-laboratory trial. The trueness and precision were evaluated as the bias and reproducibility of relative standard deviation (RSDr), respectively. The determined biases and the RSDr values were less than 30 and 13%, respectively, at all evaluated concentrations. The limit of quantitation of the method was 0.5%, and the developed method would thus be applicable for practical analyses for the detection and quantification of MON87701.
Johnston, Patrick A; Brown, Robert C
2014-08-13
A rapid method for the quantitation of total sugars in pyrolysis liquids using high-performance liquid chromatography (HPLC) was developed. The method avoids the tedious and time-consuming sample preparation required by current analytical methods. It is possible to directly analyze hydrolyzed pyrolysis liquids, bypassing the neutralization step usually required in determination of total sugars. A comparison with traditional methods was used to determine the validity of the results. The calibration curve coefficient of determination on all standard compounds was >0.999 using a refractive index detector. The relative standard deviation for the new method was 1.13%. The spiked sugar recoveries on the pyrolysis liquid samples were between 104 and 105%. The research demonstrates that it is possible to obtain excellent accuracy and efficiency using HPLC to quantitate glucose after acid hydrolysis of polymeric and oligomeric sugars found in fast pyrolysis bio-oils without neutralization.
Evolution of microbiological analytical methods for dairy industry needs
Sohier, Danièle; Pavan, Sonia; Riou, Armelle; Combrisson, Jérôme; Postollec, Florence
2014-01-01
Traditionally, culture-based methods have been used to enumerate microbial populations in dairy products. Recent developments in molecular methods now enable faster and more sensitive analyses than classical microbiology procedures. These molecular tools allow a detailed characterization of cell physiological states and bacterial fitness and thus, offer new perspectives to integration of microbial physiology monitoring to improve industrial processes. This review summarizes the methods described to enumerate and characterize physiological states of technological microbiota in dairy products, and discusses the current deficiencies in relation to the industry’s needs. Recent studies show that Polymerase chain reaction-based methods can successfully be applied to quantify fermenting microbes and probiotics in dairy products. Flow cytometry and omics technologies also show interesting analytical potentialities. However, they still suffer from a lack of validation and standardization for quality control analyses, as reflected by the absence of performance studies and official international standards. PMID:24570675
High-throughput real-time quantitative reverse transcription PCR.
Bookout, Angie L; Cummins, Carolyn L; Mangelsdorf, David J; Pesola, Jean M; Kramer, Martha F
2006-02-01
Extensive detail on the application of the real-time quantitative polymerase chain reaction (QPCR) for the analysis of gene expression is provided in this unit. The protocols are designed for high-throughput, 384-well-format instruments, such as the Applied Biosystems 7900HT, but may be modified to suit any real-time PCR instrument. QPCR primer and probe design and validation are discussed, and three relative quantitation methods are described: the standard curve method, the efficiency-corrected DeltaCt method, and the comparative cycle time, or DeltaDeltaCt method. In addition, a method is provided for absolute quantification of RNA in unknown samples. RNA standards are subjected to RT-PCR in the same manner as the experimental samples, thus accounting for the reaction efficiencies of both procedures. This protocol describes the production and quantitation of synthetic RNA molecules for real-time and non-real-time RT-PCR applications.
Evolution of microbiological analytical methods for dairy industry needs.
Sohier, Danièle; Pavan, Sonia; Riou, Armelle; Combrisson, Jérôme; Postollec, Florence
2014-01-01
Traditionally, culture-based methods have been used to enumerate microbial populations in dairy products. Recent developments in molecular methods now enable faster and more sensitive analyses than classical microbiology procedures. These molecular tools allow a detailed characterization of cell physiological states and bacterial fitness and thus, offer new perspectives to integration of microbial physiology monitoring to improve industrial processes. This review summarizes the methods described to enumerate and characterize physiological states of technological microbiota in dairy products, and discusses the current deficiencies in relation to the industry's needs. Recent studies show that Polymerase chain reaction-based methods can successfully be applied to quantify fermenting microbes and probiotics in dairy products. Flow cytometry and omics technologies also show interesting analytical potentialities. However, they still suffer from a lack of validation and standardization for quality control analyses, as reflected by the absence of performance studies and official international standards.
76 FR 54293 - Review of National Ambient Air Quality Standards for Carbon Monoxide
Federal Register 2010, 2011, 2012, 2013, 2014
2011-08-31
...This rule is being issued at this time as required by a court order governing the schedule for completion of this review of the air quality criteria and the national ambient air quality standards (NAAQS) for carbon monoxide (CO). Based on its review, the EPA concludes the current primary standards are requisite to protect public health with an adequate margin of safety, and is retaining those standards. After review of the air quality criteria, EPA further concludes that no secondary standard should be set for CO at this time. EPA is also making changes to the ambient air monitoring requirements for CO, including those related to network design, and is updating, without substantive change, aspects of the Federal reference method.
Validation and Recommendation of Methods to Measure Biogas Production Potential of Animal Manure
Pham, C. H.; Triolo, J. M.; Cu, T. T. T.; Pedersen, L.; Sommer, S. G.
2013-01-01
In developing countries, biogas energy production is seen as a technology that can provide clean energy in poor regions and reduce pollution caused by animal manure. Laboratories in these countries have little access to advanced gas measuring equipment, which may limit research aimed at improving local adapted biogas production. They may also be unable to produce valid estimates of an international standard that can be used for articles published in international peer-reviewed science journals. This study tested and validated methods for measuring total biogas and methane (CH4) production using batch fermentation and for characterizing the biomass. The biochemical methane potential (BMP) (CH4 NL kg−1 VS) of pig manure, cow manure and cellulose determined with the Moller and VDI methods was not significantly different in this test (p>0.05). The biodegradability using a ratio of BMP and theoretical BMP (TBMP) was slightly higher using the Hansen method, but differences were not significant. Degradation rate assessed by methane formation rate showed wide variation within the batch method tested. The first-order kinetics constant k for the cumulative methane production curve was highest when two animal manures were fermented using the VDI 4630 method, indicating that this method was able to reach steady conditions in a shorter time, reducing fermentation duration. In precision tests, the repeatability of the relative standard deviation (RSDr) for all batch methods was very low (4.8 to 8.1%), while the reproducibility of the relative standard deviation (RSDR) varied widely, from 7.3 to 19.8%. In determination of biomethane concentration, the values obtained using the liquid replacement method (LRM) were comparable to those obtained using gas chromatography (GC). This indicates that the LRM method could be used to determine biomethane concentration in biogas in laboratories with limited access to GC. PMID:25049861
USDA-ARS?s Scientific Manuscript database
Reverse Transcription quantitative Polymerase Chain Reaction (qRT-PCR) is a popular method for measuring transcript abundance. The most commonly used method of interpretation is relative quantification and thus necessitates the use of normalization controls (i.e. reference genes) to standardize tran...
ERIC Educational Resources Information Center
Nevitt, Johnathan; Hancock, Gregory R.
Though common structural equation modeling (SEM) methods are predicated upon the assumption of multivariate normality, applied researchers often find themselves with data clearly violating this assumption and without sufficient sample size to use distribution-free estimation methods. Fortunately, promising alternatives are being integrated into…
ERIC Educational Resources Information Center
Meester-Delver, Anke; Beelen, Anita; Hennekam, Raoul; Nollet, Frans; Hadders-Algra, Mijna
2007-01-01
The aim of this study was to determine the interrater reliability and stability over time of the Capacity Profile (CAP). The CAP is a standardized method for classifying additional care needs indicated by current impairments in five domains of body functions: physical health, neuromusculoskeletal and movement-related, sensory, mental, and voice…
Qualitative Research in Career Development: Content Analysis from 1990 to 2009
ERIC Educational Resources Information Center
Stead, Graham B.; Perry, Justin C.; Munka, Linda M.; Bonnett, Heather R.; Shiban, Abbey P.; Care, Esther
2012-01-01
A content analysis of 11 journals that published career, vocational, and work-related articles from 1990 to 2009 was conducted. Of 3,279 articles analyzed, 55.9% used quantitative methods and 35.5% were theoretical/conceptual articles. Only 6.3% used qualitative research methods. Among the qualitative empirical studies, standards of academic rigor…
ERIC Educational Resources Information Center
Blackwell, H. Richard
1963-01-01
An application method for evaluating the visual significance of reflected glare is described, based upon a number of decisions with respect to the relative importance of various aspects of visual performance. A standardized procedure for evaluating the overall effectiveness of lighting from photometric data on materials or installations is needed…
2004-05-01
following digestion using method 3005A. Copper concentrations were verified using atomic absorption spectroscopy/graphite furnace. Each chamber...1995. Ammonia Variation in Sediments: Spatial, Temporal and Method -Related Effects. Environ. Toxicol. Chem. 14:1499-1506. Savage, W.K., F.W...Regulator Approved Methods and Protocols for Conducting Marine and Terrestrial Risk Assessments 1.III.01.k - Improved Field Analytical Sensors
The Manufacture, Shipping and Receiving and Quality Control of Rodent Bedding Materials
NASA Technical Reports Server (NTRS)
Kraft, Lisbeth M.
1980-01-01
The criteria for rodent bedding and nesting materials are discussed. The literature is reviewed regarding sources of bedding materials, manufacturing methods, quality control, procedures (microbiological, physical and chemical), storage, methods, shipment, methods of use and disposal, current knowledge concerning bedding effects on animals as related to research and testing and legal aspects. Future needs, especially with respect to the promulgation of standards, also are addressed.
The storage stability of biogenic volatile organic compounds (BVOCs) in polyester aluminum bags
NASA Astrophysics Data System (ADS)
Ahn, Jeong-Hyeon; Deep, Akash; Kim, Ki-Hyun
2016-09-01
In this study, the sorptive loss properties of biogenic volatile organic compounds (BVOCs) in polyester aluminum bags were investigated as a function of storage duration. To this end, the relative recovery of gas phase standards of BVOCs, obtained via vaporization of liquid phase standards, was computed by calibrating their standards (response factors: RF) represnting each phase. Accordingly, the results indicated either slight loss (-5.59% (isoprene), -2.39% (camphene), -1.69% ((R)-(+)-limonene), -0.88% (p-cymene)) or gain (1.47% (γ-terpinene), 2.27% (α-terpinene), 2.63% (α-phellandrene), 2.73% ((+)-3-carene), 3.93% ((+)-β-pinene), and 5.98% ((+)-α-pinene)). Through comparison of the calibration results across storage time, the temporal stability of BVOCs was assessed. Longer BVOC storage time in polyester aluminum (PEA) bags lowered the relative recovery of BVOCs. The relative loss of BVOCs, if calculated in terms of mean bag standard RF ratios (relative to liquid standard) across elapsed time, decreased systematically: 0.99 ± 0.05 (0 h), 0.88 ± 0.06 (24 h), 0.66 ± 0.11 (72 h), and 0.62 ± 0.14 (120 h). It is thus recommended to complete the analysis of BVOC in PEA bags within 24 h of sample acquisition. As such, it is important to apply appropriate sampling approaches with a proper storage plan when measuring ambient BVOCs collected by bag sampling methods.
Chen, Ge; Jin, Maojun; Du, Pengfei; Zhang, Chan; Cui, Xueyan; Zhang, Yudan; She, Yongxin; Shao, Hua; Jin, Fen; Wang, Shanshan; Zheng, Lufei; Wang, Jing
2017-08-01
The chemiluminescence enzyme immunoassay (CLEIA) method responds differently to various sample matrices because of the matrix effect. In this work, the CLEIA method was coupled with molecularly imprinted polymers (MIPs) synthesized by precipitation polymerization to study the matrix effect. The sample recoveries ranged from 72.62% to 121.89%, with a relative standard deviation (RSD) of 3.74-18.14%.The ratio of the sample matrix-matched standard curve slope rate to the solvent standard curve slope was 1.21, 1.12, 1.17, and 0.85 for apple, rice, orange and cabbage in samples pretreated with the mixture of PSA and C 18 . However, the ratio of sample (apple, rice, orange, and cabbage) matrix-matched standard-MIPs curve slope rate to the solvent standard curve was 1.05, 0.92, 1.09, and 1.05 in samples pretreated with MIPs, respectively. The results demonstrated that the matrices of the samples greatly interfered with the detection of parathion residues by CLEIA. The MIPs bound specifically to the parathion in the samples and eliminated the matrix interference effect. Therefore, the CLEIA method have successfully applied MIPs in sample pretreatment to eliminate matrix interference effects and provided a new sensitive assay for agro-products. Copyright © 2017 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Loureiro, A. D.; Gomes, L. M.; Ventura, L.
2018-02-01
The international standard ISO 12312-1 proposes transmittance tests that quantify how dark sunglasses lenses are and whether or not they are suitable for driving. To perform these tests a spectrometer is required. In this study, we present and analyze theoretically an accurate alternative method for performing these measurements using simple components. Using three LEDs and a four-channel sensor we generated weighting functions similar to the standard ones for luminous and traffic lights transmittances. From 89 sunglasses lens spectroscopy data, we calculated luminous transmittance and signal detection quotients using our obtained weighting functions and the standard ones. Mean-difference Tukey plots were used to compare the results. All tested sunglasses lenses were classified in the right category and correctly as suitable or not for driving. The greatest absolute errors for luminous transmittance and red, yellow, green and blue signal detection quotients were 0.15%, 0.17, 0.06, 0.04 and 0.18, respectively. This method will be used in a device capable to perform transmittance tests (visible, traffic lights and ultraviolet (UV)) according to the standard. It is important to measure rightly luminous transmittance and relative visual attenuation quotients to report correctly whether or not sunglasses are suitable for driving. Moreover, standard UV requirements depend on luminous transmittance.
Gosselin, Robert C; Adcock, Dorothy M; Bates, Shannon M; Douxfils, Jonathan; Favaloro, Emmanuel J; Gouin-Thibault, Isabelle; Guillermo, Cecilia; Kawai, Yohko; Lindhoff-Last, Edelgard; Kitchen, Steve
2018-03-01
This guidance document was prepared on behalf of the International Council for Standardization in Haematology (ICSH) for providing haemostasis-related guidance documents for clinical laboratories. This inaugural coagulation ICSH document was developed by an ad hoc committee, comprised of international clinical and laboratory direct acting oral anticoagulant (DOAC) experts. The committee developed consensus recommendations for laboratory measurement of DOACs (dabigatran, rivaroxaban, apixaban and edoxaban), which would be germane for laboratories assessing DOAC anticoagulation. This guidance document addresses all phases of laboratory DOAC measurements, including pre-analytical (e.g. preferred time sample collection, preferred sample type, sample stability), analytical (gold standard method, screening and quantifying methods) and post analytical (e.g. reporting units, quality assurance). The committee addressed the use and limitations of screening tests such as prothrombin time, activated partial thromboplastin time as well as viscoelastic measurements of clotting blood and point of care methods. Additionally, the committee provided recommendations for the proper validation or verification of performance of laboratory assays prior to implementation for clinical use, and external quality assurance to provide continuous assessment of testing and reporting method. Schattauer GmbH Stuttgart.
Bekiroglu, Somer; Myrberg, Olle; Ostman, Kristina; Ek, Marianne; Arvidsson, Torbjörn; Rundlöf, Torgny; Hakkarainen, Birgit
2008-08-05
A 1H-nuclear magnetic resonance (NMR) spectroscopy method for quantitative determination of benzethonium chloride (BTC) as a constituent of grapefruit seed extract was developed. The method was validated, assessing its specificity, linearity, range, and precision, as well as accuracy, limit of quantification and robustness. The method includes quantification using an internal reference standard, 1,3,5-trimethoxybenzene, and regarded as simple, rapid, and easy to implement. A commercial grapefruit seed extract was studied and the experiments were performed on spectrometers operating at two different fields, 300 and 600 MHz for proton frequencies, the former with a broad band (BB) probe and the latter equipped with both a BB probe and a CryoProbe. The concentration average for the product sample was 78.0, 77.8 and 78.4 mg/ml using the 300 BB probe, the 600MHz BB probe and CryoProbe, respectively. The standard deviation and relative standard deviation (R.S.D., in parenthesis) for the average concentrations was 0.2 (0.3%), 0.3 (0.4%) and 0.3mg/ml (0.4%), respectively.
A semi-automated methodology for finding lipid-related GO terms.
Fan, Mengyuan; Low, Hong Sang; Wenk, Markus R; Wong, Limsoon
2014-01-01
Although semantic similarity in Gene Ontology (GO) and other approaches may be used to find similar GO terms, there is yet a method to systematically find a class of GO terms sharing a common property with high accuracy (e.g., involving human curation). We have developed a methodology to address this issue and applied it to identify lipid-related GO terms, owing to the important and varied roles of lipids in many biological processes. Our methodology finds lipid-related GO terms in a semi-automated manner, requiring only moderate manual curation. We first obtain a list of lipid-related gold-standard GO terms by keyword search and manual curation. Then, based on the hypothesis that co-annotated GO terms share similar properties, we develop a machine learning method that expands the list of lipid-related terms from the gold standard. Those terms predicted most likely to be lipid related are examined by a human curator following specific curation rules to confirm the class labels. The structure of GO is also exploited to help reduce the curation effort. The prediction and curation cycle is repeated until no further lipid-related term is found. Our approach has covered a high proportion, if not all, of lipid-related terms with relatively high efficiency. http://compbio.ddns.comp.nus.edu.sg/∼lipidgo. © The Author(s) 2014. Published by Oxford University Press.
NASA Technical Reports Server (NTRS)
Kim, W. S.; Seng, G. T.
1982-01-01
A rapid ultraviolet spectrophotometric method for the simultaneous determination of aromatics in middistillate fuels was developed and evaluated. In this method, alkylbenzenes, alkylnaphthalenes, alkylanthracenes/phenanthracenes and total aromatics were determined from ultraviolet spectra of the fuels. The accuracy and precision were determined using simulated standard fuels with known compositions. The total aromatics fraction accuracy was 5% for a Jet A type fuel and 0.6% for a broadened properties jet turbine type fuel. Precision, expressed as relative standard deviations, ranged from 2.9% for the alkylanthracenes/phenanthrenes to 15.3% for the alkylbenzenes. The accuracy, however, was less for actual fuel samples when compared to the results obtained by a mass spectrometric method. In addition, the ASTM D-1840 method for naphthalenes by ultraviolet spectroscopy was evaluated.
Application of micromechanics to the characterization of mortar by ultrasound.
Hernández, M G; Anaya, J J; Izquierdo, M A G; Ullate, L G
2002-05-01
Mechanical properties of concrete and mortar structures can be estimated by ultrasonic non-destructive testing. When the ultrasonic velocity is known, there are standardized methods based on considering the concrete a homogeneous material. Cement composites, however, are heterogeneous and porous, and have a negative effect on the mechanical properties of structures. This work studies the impact of porosity on mechanical properties by considering concrete a multiphase material. A micromechanical model is applied in which the material is considered to consist of two phases: a solid matrix and pores. From this method, a set of expressions is obtained that relates the acoustic velocity and Young's modulus of mortar. Experimental work is based on non-destructive and destructive procedures over mortar samples whose porosity is varied. A comparison is drawn between micromechanical and standard methods, showing positive results for the method here proposed.
NASA Astrophysics Data System (ADS)
Taer, Erman; Taslim, Rika
2018-02-01
The synthesis of activated carbon monolith electrode made from a biomass material using the hydrolytic pressure or the pelletization technique of pre-carbonized materials is one of standard reported methods. Several steps such as pre-carbonization, milling, chemical activation, hydraulic press, carbonization, physical activation, polishing and washing need to be accomplished in the production of electrodes by this method. This is relatively a long process that need to be simplified. In this paper we present the standard method and proceed with the introduction to several alternative methods in the synthesis of activated carbon monolith electrodes. The alternative methods were emphasized on the selection of suitable biomass materials. All of carbon electrodes prepared by different methods will be analyzed for physical and electrochemical properties. The density, degree of crystallinity, surface morphology are examples for physical study and specific capacitance was an electrochemical properties that has been analysed. This alternative method has offered a specific capacitance in the range of 10 to 171 F/g.
Canagaratna, M. R.; Jimenez, J. L.; Kroll, J. H.; ...
2015-01-12
Elemental compositions of organic aerosol (OA) particles provide useful constraints on OA sources, chemical evolution, and effects. The Aerodyne high-resolution time-of-flight aerosol mass spectrometer (HR-ToF-AMS) is widely used to measure OA elemental composition. This study evaluates AMS measurements of atomic oxygen-to-carbon (O : C), hydrogen-to-carbon (H : C), and organic mass-to-organic carbon (OM : OC) ratios, and of carbon oxidation state (OS C) for a vastly expanded laboratory data set of multifunctional oxidized OA standards. For the expanded standard data set, the method introduced by Aiken et al. (2008), which uses experimentally measured ion intensities at all ions to determinemore » elemental ratios (referred to here as "Aiken-Explicit"), reproduces known O : C and H : C ratio values within 20% (average absolute value of relative errors) and 12%, respectively. The more commonly used method, which uses empirically estimated H 2O + and CO + ion intensities to avoid gas phase air interferences at these ions (referred to here as "Aiken-Ambient"), reproduces O : C and H : C of multifunctional oxidized species within 28 and 14% of known values. The values from the latter method are systematically biased low, however, with larger biases observed for alcohols and simple diacids. A detailed examination of the H 2O +, CO +, and CO 2 + fragments in the high-resolution mass spectra of the standard compounds indicates that the Aiken-Ambient method underestimates the CO + and especially H 2O + produced from many oxidized species. Combined AMS–vacuum ultraviolet (VUV) ionization measurements indicate that these ions are produced by dehydration and decarboxylation on the AMS vaporizer (usually operated at 600 °C). Thermal decomposition is observed to be efficient at vaporizer temperatures down to 200 °C. These results are used together to develop an "Improved-Ambient" elemental analysis method for AMS spectra measured in air. The Improved-Ambient method uses specific ion fragments as markers to correct for molecular functionality-dependent systematic biases and reproduces known O : C (H : C) ratios of individual oxidized standards within 28% (13%) of the known molecular values. The error in Improved-Ambient O : C (H : C) values is smaller for theoretical standard mixtures of the oxidized organic standards, which are more representative of the complex mix of species present in ambient OA. For ambient OA, the Improved-Ambient method produces O : C (H : C) values that are 27% (11%) larger than previously published Aiken-Ambient values; a corresponding increase of 9% is observed for OM : OC values. These results imply that ambient OA has a higher relative oxygen content than previously estimated. The OS C values calculated for ambient OA by the two methods agree well, however (average relative difference of 0.06 OS C units). This indicates that OS C is a more robust metric of oxidation than O : C, likely since OS C is not affected by hydration or dehydration, either in the atmosphere or during analysis.« less
Zhang, Jingjing; Liang, Jiabi; Tian, Yuan; Zhang, Zunjian; Chen, Yun
2007-10-15
A rapid, sensitive and selective LC-MS/MS method was developed and validated for the quantification of aniracetam in human plasma using estazolam as internal standard (IS). Following liquid-liquid extraction, the analytes were separated using a mobile phase of methanol-water (60:40, v/v) on a reverse phase C18 column and analyzed by a triple-quadrupole mass spectrometer in the selected reaction monitoring (SRM) mode using the respective [M+H]+ ions, m/z 220-->135 for aniracetam and m/z 295-->205 for the IS. The assay exhibited a linear dynamic range of 0.2-100 ng/mL for aniracetam in human plasma. The lower limit of quantification (LLOQ) was 0.2 ng/mL with a relative standard deviation of less than 15%. Acceptable precision and accuracy were obtained for concentrations over the standard curve range. The validated LC-MS/MS method has been successfully applied to study the pharmacokinetics of aniracetam in healthy male Chinese volunteers.
Pang, Susan; Cowen, Simon
2017-12-13
We describe a novel generic method to derive the unknown endogenous concentrations of analyte within complex biological matrices (e.g. serum or plasma) based upon the relationship between the immunoassay signal response of a biological test sample spiked with known analyte concentrations and the log transformed estimated total concentration. If the estimated total analyte concentration is correct, a portion of the sigmoid on a log-log plot is very close to linear, allowing the unknown endogenous concentration to be estimated using a numerical method. This approach obviates conventional relative quantification using an internal standard curve and need for calibrant diluent, and takes into account the individual matrix interference on the immunoassay by spiking the test sample itself. This technique is based on standard additions for chemical analytes. Unknown endogenous analyte concentrations within even 2-fold diluted human plasma may be determined reliably using as few as four reaction wells.
Evaluation of diagnostic accuracy in detecting ordered symptom statuses without a gold standard
Wang, Zheyu; Zhou, Xiao-Hua; Wang, Miqu
2011-01-01
Our research is motivated by 2 methodological problems in assessing diagnostic accuracy of traditional Chinese medicine (TCM) doctors in detecting a particular symptom whose true status has an ordinal scale and is unknown—imperfect gold standard bias and ordinal scale symptom status. In this paper, we proposed a nonparametric maximum likelihood method for estimating and comparing the accuracy of different doctors in detecting a particular symptom without a gold standard when the true symptom status had an ordered multiple class. In addition, we extended the concept of the area under the receiver operating characteristic curve to a hyper-dimensional overall accuracy for diagnostic accuracy and alternative graphs for displaying a visual result. The simulation studies showed that the proposed method had good performance in terms of bias and mean squared error. Finally, we applied our method to our motivating example on assessing the diagnostic abilities of 5 TCM doctors in detecting symptoms related to Chills disease. PMID:21209155
ERIC Educational Resources Information Center
Donohue, Brad; Allen, Daniel N.; Romero, Valerie; Hill, Heather H.; Vasaeli, Kathryn; Lapota, Holly; Tracy, Kendra; Gorney, Suzanne; Abdel-al, Ruweida; Caldas, Diana; Herdzik, Karen; Bradshaw, Kelsey; Valdez, Robby; Van Hasselt, Vincent B.
2009-01-01
Developers of evidence-based therapies are enhancing methods of teaching therapists to implement "best practices" with integrity. However, there is a relative dearth of information available as to clinic operations and related contextual factors necessary to sustain successful implementation of these treatments. This article describes various…
Convergence of microclimate in residential landscapes across diverse cities in the United States
Sharon J. Hall; J. Learned; B. Ruddell; K.L. Larson; J. Cavender-Bares; N. Bettez; P.M. Groffman; Morgan Grove; J.B. Heffernan; S.E. Hobbie; J.L. Morse; C. Neill; K.C. Nelson; Jarlath O' Neil-Dunne; L. Ogden; D.E. Pataki; W.D. Pearse; C. Polsky; R. Roy Chowdhury; M.K. Steele; T.L.E. Trammell
2016-01-01
The urban heat island (UHI) is a well-documented pattern of warming in cities relative to rural areas. Most UHI research utilizes remote sensing methods at large scales, or climate sensors in single cities surrounded by standardized land cover. Relatively few studies have explored continental-scale climatic patterns within common urban microenvironments such as...
Estimating airline operating costs
NASA Technical Reports Server (NTRS)
Maddalon, D. V.
1978-01-01
A review was made of the factors affecting commercial aircraft operating and delay costs. From this work, an airline operating cost model was developed which includes a method for estimating the labor and material costs of individual airframe maintenance systems. The model, similar in some respects to the standard Air Transport Association of America (ATA) Direct Operating Cost Model, permits estimates of aircraft-related costs not now included in the standard ATA model (e.g., aircraft service, landing fees, flight attendants, and control fees). A study of the cost of aircraft delay was also made and a method for estimating the cost of certain types of airline delay is described.
Gravimetric screening method for fungal decay of paper: inoculation with Trametes versicolor.
Råberg, Ulrika; Hafrén, Jonas
2009-10-01
The European standard test EN 113 for fungal degradation of solid wood has been adapted for degradation of paper by white rot fungus (Trametes versicolor). Fungal degradation of paper sheets may potentially be used for screening different wood preservatives on paper instead of solid wood. The paper samples showed higher relative mass losses compared to wood, and samples pretreated with boric acid, copper sulfate and polymerized linseed oil were successfully tested for biodegradation using the paper sheet method. The results on paper degradation were compared with wood, both as wood blocks (according to standard test) and wood cut in sections forming layered structures mimicking paper layers.
Ansermot, Nicolas; Rudaz, Serge; Brawand-Amey, Marlyse; Fleury-Souverain, Sandrine; Veuthey, Jean-Luc; Eap, Chin B
2009-08-01
Matrix effects, which represent an important issue in liquid chromatography coupled to mass spectrometry or tandem mass spectrometry detection, should be closely assessed during method development. In the case of quantitative analysis, the use of stable isotope-labelled internal standard with physico-chemical properties and ionization behaviour similar to the analyte is recommended. In this paper, an example of the choice of a co-eluting deuterated internal standard to compensate for short-term and long-term matrix effect in the case of chiral (R,S)-methadone plasma quantification is reported. The method was fully validated over a concentration range of 5-800 ng/mL for each methadone enantiomer with satisfactory relative bias (-1.0 to 1.0%), repeatability (0.9-4.9%) and intermediate precision (1.4-12.0%). From the results obtained during validation, a control chart process during 52 series of routine analysis was established using both intermediate precision standard deviation and FDA acceptance criteria. The results of routine quality control samples were generally included in the +/-15% variability around the target value and mainly in the two standard deviation interval illustrating the long-term stability of the method. The intermediate precision variability estimated in method validation was found to be coherent with the routine use of the method. During this period, 257 trough concentration and 54 peak concentration plasma samples of patients undergoing (R,S)-methadone treatment were successfully analysed for routine therapeutic drug monitoring.
Hillemeier, Marianne M.; Lynch, John; Harper, Sam; Raghunathan, Trivellore; Kaplan, George A.
2003-01-01
Objectives. The purpose of the present study was to compare the associations of state-referenced and federal poverty measures with states’ infant and child mortality rates. Methods. Compressed mortality and Current Population Survey data were used to examine relationships between mortality and (1) state-referenced poverty (percentage of children below half the state median income) and (2) percentage of children below the federal poverty line. Results. State-referenced poverty was not associated with mortality among infants or children, whereas poverty as defined by national standards was strongly related to mortality. Conclusions. Infant and child mortality is more closely tied to families’ capacity for meeting basic needs than to relative position within a state’s economic hierarchy. PMID:12660213
29 CFR 779.413 - Methods of compensation of retail store employees.
Code of Federal Regulations, 2010 CFR
2010-07-01
... STANDARDS ACT AS APPLIED TO RETAILERS OF GOODS OR SERVICES Provisions Relating to Certain Employees of... represent commissions “on goods or services,” which would include all types of commissions customarily based...
Gao, Xiaoli; Zhang, Qibin; Meng, Da; Issac, Giorgis; Zhao, Rui; Fillmore, Thomas L.; Chu, Rosey K.; Zhou, Jianying; Tang, Keqi; Hu, Zeping; Moore, Ronald J.; Smith, Richard D.; Katze, Michael G.; Metz, Thomas O.
2012-01-01
Lipidomics is a critical part of metabolomics and aims to study all the lipids within a living system. We present here the development and evaluation of a sensitive capillary UPLC-MS method for comprehensive top-down/bottom-up lipid profiling. Three different stationary phases were evaluated in terms of peak capacity, linearity, reproducibility, and limit of quantification (LOQ) using a mixture of lipid standards representative of the lipidome. The relative standard deviations of the retention times and peak abundances of the lipid standards were 0.29% and 7.7%, respectively, when using the optimized method. The linearity was acceptable at >0.99 over 3 orders of magnitude, and the LOQs were sub-fmol. To demonstrate the performance of the method in the analysis of complex samples, we analyzed lipids extracted from a human cell line, rat plasma, and a model human skin tissue, identifying 446, 444, and 370 unique lipids, respectively. Overall, the method provided either higher coverage of the lipidome, greater measurement sensitivity, or both, when compared to other approaches of global, untargeted lipid profiling based on chromatography coupled with MS. PMID:22354571
On the influence of high-pass filtering on ICA-based artifact reduction in EEG-ERP.
Winkler, Irene; Debener, Stefan; Müller, Klaus-Robert; Tangermann, Michael
2015-01-01
Standard artifact removal methods for electroencephalographic (EEG) signals are either based on Independent Component Analysis (ICA) or they regress out ocular activity measured at electrooculogram (EOG) channels. Successful ICA-based artifact reduction relies on suitable pre-processing. Here we systematically evaluate the effects of high-pass filtering at different frequencies. Offline analyses were based on event-related potential data from 21 participants performing a standard auditory oddball task and an automatic artifactual component classifier method (MARA). As a pre-processing step for ICA, high-pass filtering between 1-2 Hz consistently produced good results in terms of signal-to-noise ratio (SNR), single-trial classification accuracy and the percentage of `near-dipolar' ICA components. Relative to no artifact reduction, ICA-based artifact removal significantly improved SNR and classification accuracy. This was not the case for a regression-based approach to remove EOG artifacts.
Turkia, Heidi; Sirén, Heli; Penttilä, Merja; Pitkänen, Juha-Pekka
2015-01-01
The amino acid composition of cultivation broth is known to affect the biomass accumulation, productivity, and vitality of yeast during cultivation. A separation method based on capillary electrophoresis with laser-induced fluorescence (LIF) detection was developed for the determination of amino acid consumption by Saccharomyces cerevisiae during beer fermentation. Intraday relative standard deviations were less than 2.1% for migration times and between 2.9% and 9.9% for peak areas. Interday relative standard deviations were less than 2.5% for migration times and between 4.4% and 18.9% for peak areas. The quantification limit was even as low as 62.5 pM which equals to below attomole level detection. The method was applied to study the rate of amino acid utilization during beer fermentation. Copyright © 2014 Elsevier B.V. All rights reserved.
Iturrate, Iñaki; Grizou, Jonathan; Omedes, Jason; Oudeyer, Pierre-Yves; Lopes, Manuel; Montesano, Luis
2015-01-01
This paper presents a new approach for self-calibration BCI for reaching tasks using error-related potentials. The proposed method exploits task constraints to simultaneously calibrate the decoder and control the device, by using a robust likelihood function and an ad-hoc planner to cope with the large uncertainty resulting from the unknown task and decoder. The method has been evaluated in closed-loop online experiments with 8 users using a previously proposed BCI protocol for reaching tasks over a grid. The results show that it is possible to have a usable BCI control from the beginning of the experiment without any prior calibration. Furthermore, comparisons with simulations and previous results obtained using standard calibration hint that both the quality of recorded signals and the performance of the system were comparable to those obtained with a standard calibration approach. PMID:26131890
Wu, Ping-gu; Ma, Bing-jie; Wang, Li-yuan; Shen, Xiang-hong; Zhang, Jing; Tan, Ying; Jiang, Wei
2013-11-01
To establish the method of simultaneous determination of methylcarbamate (MC) and ethylcarbamate (EC) in yellow rice wine by gas chromatography-mass spectrometry (GC/MS). MC and EC in yellow rice wine were derived by 9-xanthydrol, and then the derivants were detected by GC/MS; and quantitatively analyzed by D5-EC isotope internal standard method. The linearity of MC and EC ranged from 2.0 µg/L to 400.0 µg/L, with correlation coefficients at 0.998 and 0.999, respectively. The limits of quantitation (LOQ) and detection (LOD) were 0.67 and 2.0 µg/kg. When MC and EC were added in yellow rice wine at the range of 2.0-300.0 µg/kg, the intraday average recovery rate was 78.8%-102.3%, relative standard deviation was 3.2%-11.6%; interday average recovery rate was 75.4%-101.3%, relative standard deviation was 3.8%-13.4%. 20 samples of yellow rice wine from supermarket were detected using this method, the contents of MC were in the range of ND (no detected) to 1.2 µg/kg, the detection rate was 6% (3/20), the contents of EC in the range of 18.6 µg/kg to 432.3 µg/kg, with the average level at 135.2 µg/kg. The method is simple, rapid and useful for simultaneous determination of MC and EC in yellow rice wine.
Measurement and standardization of eye safety for optical radiation of LED products
NASA Astrophysics Data System (ADS)
Mou, Tongsheng; Peng, Zhenjian
2013-06-01
The blue light hazard (BLH) to human eye's retina is now a new issue emerging in applications of artificial light sources. Especially for solid state lighting sources based on the blue chip-LED(GaN), the photons with their energy more than 2.4 eV show photochemical effects on the retina significantly, raising damage both in photoreceptors and retinal pigment epithelium. The photobiological safety of artificial light sources emitting optical radiation has gained more and more attention worldwide and addressed by international standards IEC 62471-2006(CIE S009/E: 2002). Meanwhile, it is involved in IEC safety specifications of LED lighting products and covered by European Directive 2006/25/EC on the minimum health and safety requirements regarding the exposure of the workers to artificial optical radiation. In practical applications of the safety standards, the measuring methods of optical radiation from LED products to eyes are important in establishment of executable methods in the industry. In 2011, a new project to develop the international standard of IEC TR62471-4,that is "Measuring methods of optical radiation related to photobiological safety", was approved and are now under way. This paper presents the concerned methods for the assessment of optical radiation hazards in the standards. Furthermore, a retina radiance meter simulating eye's optical geometry is also described, which is a potential tool for blue light hazard assessment of retinal exposure to optical radiation. The spectroradiometric method integrated with charge-coupled device(CCD) imaging system is introduced to provide more reliable results.
Do placebo based validation standards mimic real batch products behaviour? Case studies.
Bouabidi, A; Talbi, M; Bouklouze, A; El Karbane, M; Bourichi, H; El Guezzar, M; Ziemons, E; Hubert, Ph; Rozet, E
2011-06-01
Analytical methods validation is a mandatory step to evaluate the ability of developed methods to provide accurate results for their routine application. Validation usually involves validation standards or quality control samples that are prepared in placebo or reconstituted matrix made of a mixture of all the ingredients composing the drug product except the active substance or the analyte under investigation. However, one of the main concerns that can be made with this approach is that it may lack an important source of variability that come from the manufacturing process. The question that remains at the end of the validation step is about the transferability of the quantitative performance from validation standards to real authentic drug product samples. In this work, this topic is investigated through three case studies. Three analytical methods were validated using the commonly spiked placebo validation standards at several concentration levels as well as using samples coming from authentic batch samples (tablets and syrups). The results showed that, depending on the type of response function used as calibration curve, there were various degrees of differences in the results accuracy obtained with the two types of samples. Nonetheless the use of spiked placebo validation standards was showed to mimic relatively well the quantitative behaviour of the analytical methods with authentic batch samples. Adding these authentic batch samples into the validation design may help the analyst to select and confirm the most fit for purpose calibration curve and thus increase the accuracy and reliability of the results generated by the method in routine application. Copyright © 2011 Elsevier B.V. All rights reserved.
2012-01-01
Background Profiling sperm DNA present on vaginal swabs taken from rape victims often contributes to identifying and incarcerating rapists. Large amounts of the victim’s epithelial cells contaminate the sperm present on swabs, however, and complicate this process. The standard method for obtaining relatively pure sperm DNA from a vaginal swab is to digest the epithelial cells with Proteinase K in order to solubilize the victim’s DNA, and to then physically separate the soluble DNA from the intact sperm by pelleting the sperm, removing the victim’s fraction, and repeatedly washing the sperm pellet. An alternative approach that does not require washing steps is to digest with Proteinase K, pellet the sperm, remove the victim’s fraction, and then digest the residual victim’s DNA with a nuclease. Methods The nuclease approach has been commercialized in a product, the Erase Sperm Isolation Kit (PTC Labs, Columbia, MO, USA), and five crime laboratories have tested it on semen-spiked female buccal swabs in a direct comparison with their standard methods. Comparisons have also been performed on timed post-coital vaginal swabs and evidence collected from sexual assault cases. Results For the semen-spiked buccal swabs, Erase outperformed the standard methods in all five laboratories and in most cases was able to provide a clean male profile from buccal swabs spiked with only 1,500 sperm. The vaginal swabs taken after consensual sex and the evidence collected from rape victims showed a similar pattern of Erase providing superior profiles. Conclusions In all samples tested, STR profiles of the male DNA fractions obtained with Erase were as good as or better than those obtained using the standard methods. PMID:23211019
Testing and Improving the Luminosity Relations for Gamma-Ray Bursts
NASA Astrophysics Data System (ADS)
Collazzi, Andrew C.
2012-01-01
Gamma Ray Bursts (GRBs) have several luminosity relations where a measurable property of a burst light curve or spectrum is correlated with the burst luminosity. These luminosity relations are calibrated for the fraction of bursts with spectroscopic redshifts and hence the known luminosities. GRBs have thus become known as a type of "standard candle” where standard candle is meant in the usual sense that luminosities can be derived from measurable properties of the bursts. GRBs can therefore be used for the same cosmology applications as Type Ia supernovae, including the construction of the Hubble Diagram and measuring massive star formation rate. The greatest disadvantage of using GRBs as standard candles is that their accuracy is lower than desired. With the recent advent of GRBs as a new standard candle, every effort must be made to test and improve the distance measures. Here, methods are employed to do just that. First, generalized forms of two tests are performed on the luminosity relations. All the luminosity relations pass one of these tests, and all but two pass the other. Even with this failure, redundancies in using multiple luminosity relations allows all the luminosity relations to retain value. Next, the "Firmani relation” is shown to have poorer accuracy than first advertised. It is also shown to be derivable from two other luminosity relations. For these reasons, the Firmani relation is useless for cosmology. The Amati relation is then revisited and shown to be an artifact of a combination of selection effects. Therefore, the Amati relation is also not good for cosmology. Fourthly, the systematic errors involved in measuring a luminosity indicator (Epeak) are measured. The result is an irreducible systematic error of 28%. Finally, the work concludes with a discussion about the impact of the work and the future of GRB luminosity relations.
The production and quality of tomato concentrates.
Hayes, W A; Smith, P G; Morris, A E
1998-10-01
The standards and specifications for the quality and composition of tomato concentrates are reviewed. The main quality parameters of tomato puree and paste are color, consistency and flavor. Overall, there is an absence of standardization of methods and instruments to define quality. While color can now be measured objectively, there are currently no standard color requirements for tomato concentrates. Rheological measurements on both tomato juice and concentrates are reviewed; the power law finds wide applicability, although other rheological characteristics, particularly time dependency, have received far less attention and there has been little effort to relate rheological understanding to the commonly used empirical tests such as consistency measurements. The volatiles responsible for flavor and odor have been identified to the point where the natural odor of tomato paste can be imitated. Attempts to develop objective methods as a substitute for sensory assessment are reviewed.
Carrico, Ruth M; Coty, Mary B; Goss, Linda K; Lajoie, Andrew S
2007-02-01
This pilot study was conducted to determine whether supplementing standard classroom training methods regarding respiratory disease transmission with a visual demonstration could improve the use of personal protective equipment among emergency department nurses. Participants included 20 emergency department registered nurses randomized into 2 groups: control and intervention. The intervention group received supplemental training using the visual demonstration of respiratory particle dispersion. Both groups were then observed throughout their work shifts as they provided care during January-March 2005. Participants who received supplemental visual training correctly utilized personal protective equipment statistically more often than did participants who received only the standard classroom training. Supplementing the standard training methods with a visual demonstration can improve the use of personal protective equipment during care of patients exhibiting respiratory symptoms.
New approaches to some methodological problems of meteor science
NASA Technical Reports Server (NTRS)
Meisel, David D.
1987-01-01
Several low cost approaches to continuous radioscatter monitoring of the incoming meteor flux are described. Preliminary experiments were attempted using standard time frequency stations WWVH and CHU (on frequencies near 15 MHz) during nighttime hours. Around-the-clock monitoring using the international standard aeronautical beacon frequency of 75 MHz was also attempted. The techniques are simple and can be managed routinely by amateur astronomers with relatively little technical expertise. Time series analysis can now be performed using relatively inexpensive microcomputers. Several algorithmic approaches to the analysis of meteor rates are discussed. Methods of obtaining optimal filter predictions of future meteor flux are also discussed.
Tuberculosis disease mapping in Kedah using standardized morbidity ratio
NASA Astrophysics Data System (ADS)
Diah, Ijlal Mohd; Aziz, Nazrina; Kasim, Maznah Mat
2017-10-01
This paper presents the results of relative risk estimation that applied to TB data in Kedah using the most common approach, Standardized Morbidity Ratio (SMR). Disease mapping has been recognized as one of the methods that can be used by government and public health in order to control diseases since it can give a clear picture of the risk areas. To get good disease mapping, relative risk estimation is an important issue that need to be considered. TB risk areas will be recognized through the map. From the result, Kulim shows the lowest risk areas of contracting TB while Kota Setar has the highest risk area.
Standardized terminology for clinical trial protocols based on top-level ontological categories.
Heller, B; Herre, H; Lippoldt, K; Loeffler, M
2004-01-01
This paper describes a new method for the ontologically based standardization of concepts with regard to the quality assurance of clinical trial protocols. We developed a data dictionary for medical and trial-specific terms in which concepts and relations are defined context-dependently. The data dictionary is provided to different medical research networks by means of the software tool Onto-Builder via the internet. The data dictionary is based on domain-specific ontologies and the top-level ontology of GOL. The concepts and relations described in the data dictionary are represented in natural language, semi-formally or formally according to their use.
Ethics and methods for biological rhythm research on animals and human beings.
Portaluppi, Francesco; Smolensky, Michael H; Touitou, Yvan
2010-10-01
This article updates the ethical standards and methods for the conduct of high-quality animal and human biological rhythm research, which should be especially useful for new investigators of the rhythms of life. The editors of Chronobiology International adhere to and endorse the Code of Conduct and Best Practice Guidelines of the Committee On Publication Ethics (COPE), which encourages communication of such updates at regular intervals in the journal. The journal accepts papers representing original work, no part of which was previously submitted for publication elsewhere, except as brief abstracts, as well as in-depth reviews. The majority of research papers published in Chronobiology International entails animal and human investigations. The editors and readers of the journal expect authors of submitted manuscripts to have made an important contribution to the research of biological rhythms and related phenomena using ethical methods/procedures and unbiased, accurate, and honest reporting of findings. Authors of scientific papers are required to declare all potential conflicts of interest. The journal and its editors endorse compliance of investigators to the Guide for the Care and Use of Laboratory Animals of the Institute for Laboratory Animal Research of the National Research Council, relating to the conduct of ethical research on laboratory and other animals, and the principles of the Declaration of Helsinki of the World Medical Association, relating to the conduct of ethical research on human beings. The peer review of manuscripts by Chronobiology International thus includes judgment as to whether or not the protocols and methods conform to ethical standards. Authors are expected to show mastery of the basic methods and procedures of biological rhythm research and proper statistical assessment of data, including the appropriate application of time series data analyses, as briefly reviewed in this article. The journal editors strive to consistently achieve high standards for the research of original and review papers reported in Chronobiology International, and current examples of expectations are presented herein.
Comparison of GPS receiver DCB estimation methods using a GPS network
NASA Astrophysics Data System (ADS)
Choi, Byung-Kyu; Park, Jong-Uk; Min Roh, Kyoung; Lee, Sang-Jeong
2013-07-01
Two approaches for receiver differential code biases (DCB) estimation using the GPS data obtained from the Korean GPS network (KGN) in South Korea are suggested: the relative and single (absolute) methods. The relative method uses a GPS network, while the single method determines DCBs from a single station only. Their performance was assessed by comparing the receiver DCB values obtained from the relative method with those estimated by the single method. The daily averaged receiver DCBs obtained from the two different approaches showed good agreement for 7 days. The root mean square (RMS) value of those differences is 0.83 nanoseconds (ns). The standard deviation of the receiver DCBs estimated by the relative method was smaller than that of the single method. From these results, it is clear that the relative method can obtain more stable receiver DCBs compared with the single method over a short-term period. Additionally, the comparison between the receiver DCBs obtained by the Korea Astronomy and Space Science Institute (KASI) and those of the IGS Global Ionosphere Maps (GIM) showed a good agreement at 0.3 ns. As the accuracy of DCB values significantly affects the accuracy of ionospheric total electron content (TEC), more studies are needed to ensure the reliability and stability of the estimated receiver DCBs.
A dynamic gravimetric standard for trace water.
Brewer, P J; Goody, B A; Woods, P T; Milton, M J T
2011-10-01
A system for generating traceable reference standards of water vapor at trace levels between 5 and 2000 nmol/mol has been developed. It can provide different amount fractions of trace water vapor by using continuous accurate measurements of mass loss from a permeation device coupled with a dilution system based on an array of critical flow orifices. An estimated relative expanded uncertainty of ±2% has been achieved for most amount fractions generated. The system has been used in an international comparison and demonstrates excellent comparability with National Metrology Institutes maintaining standards of water vapor in this range using other methods.
NASA Technical Reports Server (NTRS)
Yates, E. Carson, Jr.
1987-01-01
To promote the evaluation of existing and emerging unsteady aerodynamic codes and methods for applying them to aeroelastic problems, especially for the transonic range, a limited number of aerodynamic configurations and experimental dynamic response data sets are to be designated by the AGARD Structures and Materials Panel as standards for comparison. This set is a sequel to that established several years ago for comparisons of calculated and measured aerodynamic pressures and forces. This report presents the information needed to perform flutter calculations for the first candidate standard configuration for dynamic response along with the related experimental flutter data.
Holschneider, Alexander; Hutson, John; Peña, Albert; Beket, Elhamy; Chatterjee, Subir; Coran, Arnold; Davies, Michael; Georgeson, Keith; Grosfeld, Jay; Gupta, Devendra; Iwai, Naomi; Kluth, Dieter; Martucciello, Giuseppe; Moore, Samuel; Rintala, Risto; Smith, E Durham; Sripathi, D V; Stephens, Douglas; Sen, Sudipta; Ure, Benno; Grasshoff, Sabine; Boemers, Thomas; Murphy, Feilin; Söylet, Yunus; Dübbers, Martin; Kunst, Marc
2005-10-01
Anorectal malformations (ARM) are common congenital anomalies seen throughout the world. Comparison of outcome data has been hindered because of confusion related to classification and assessment systems. The goals of the Krinkenbeck Conference on ARM was to develop standards for an International Classification of ARM based on a modification of fistula type and adding rare and regional variants, and design a system for comparable follow up studies. Lesions were classified into major clinical groups based on the fistula location (perineal, recto-urethral, recto-vesical, vestibular), cloacal lesions, those with no fistula and anal stenosis. Rare and regional variants included pouch colon, rectal atresia or stenosis, rectovaginal fistula, H-fistula and others. Groups would be analyzed according to the type of procedure performed stratified for confounding associated conditions such as sacral anomalies and tethered cord. A standard method for postoperative assessment of continence was determined. A new International diagnostic classification system, operative groupings and a method of postoperative assessment of continence was developed by consensus of a large contingent of participants experienced in the management of patients with ARM. These methods should allow for a common standardization of diagnosis and comparing postoperative results.
Taylor, Diana; Upadhyay, Ushma D; Fjerstad, Mary; Battistelli, Molly F; Weitz, Tracy A; Paul, Maureen E
2017-07-01
To develop and validate standardized criteria for assessing abortion-related incidents (adverse events, morbidities, near misses) for first-trimester aspiration abortion procedures and to demonstrate the utility of a standardized framework [the Procedural Abortion Incident Reporting & Surveillance (PAIRS) Framework] for estimating serious abortion-related adverse events. As part of a California-based study of early aspiration abortion provision conducted between 2007 and 2013, we developed and validated a standardized framework for defining and monitoring first-trimester (≤14weeks) aspiration abortion morbidity and adverse events using multiple methods: a literature review, framework criteria testing with empirical data, repeated expert reviews and data-based revisions to the framework. The final framework distinguishes incidents resulting from procedural abortion care (adverse events) from morbidity related to pregnancy, the abortion process and other nonabortion related conditions. It further classifies incidents by diagnosis (confirmatory data, etiology, risk factors), management (treatment type and location), timing (immediate or delayed), seriousness (minor or major) and outcome. Empirical validation of the framework using data from 19,673 women receiving aspiration abortions revealed almost an equal proportion of total adverse events (n=205, 1.04%) and total abortion- or pregnancy-related morbidity (n=194, 0.99%). The majority of adverse events were due to retained products of conception (0.37%), failed attempted abortion (0.15%) and postabortion infection (0.17%). Serious or major adverse events were rare (n=11, 0.06%). Distinguishing morbidity diagnoses from adverse events using a standardized, empirically tested framework confirms the very low frequency of serious adverse events related to clinic-based abortion care. The PAIRS Framework provides a useful set of tools to systematically classify and monitor abortion-related incidents for first-trimester aspiration abortion procedures. Standardization will assist healthcare providers, researchers and policymakers to anticipate morbidity and prevent abortion adverse events, improve care metrics and enhance abortion quality. Copyright © 2017 Elsevier Inc. All rights reserved.
Milton, Martin J T; Wang, Jian
2003-01-01
A new isotope dilution mass spectrometry (IDMS) method for high-accuracy quantitative analysis of gases has been developed and validated by the analysis of standard mixtures of carbon dioxide in nitrogen. The method does not require certified isotopic reference materials and does not require direct measurements of the highly enriched spike. The relative uncertainty of the method is shown to be 0.2%. Reproduced with the permission of Her Majesty's Stationery Office. Copyright Crown copyright 2003.
Koyama, Kazuya; Mitsumoto, Takuya; Shiraishi, Takahiro; Tsuda, Keisuke; Nishiyama, Atsushi; Inoue, Kazumasa; Yoshikawa, Kyosan; Hatano, Kazuo; Kubota, Kazuo; Fukushi, Masahiro
2017-09-01
We aimed to determine the difference in tumor volume associated with the reconstruction model in positron-emission tomography (PET). To reduce the influence of the reconstruction model, we suggested a method to measure the tumor volume using the relative threshold method with a fixed threshold based on peak standardized uptake value (SUV peak ). The efficacy of our method was verified using 18 F-2-fluoro-2-deoxy-D-glucose PET/computed tomography images of 20 patients with lung cancer. The tumor volume was determined using the relative threshold method with a fixed threshold based on the SUV peak . The PET data were reconstructed using the ordered-subset expectation maximization (OSEM) model, the OSEM + time-of-flight (TOF) model, and the OSEM + TOF + point-spread function (PSF) model. The volume differences associated with the reconstruction algorithm (%VD) were compared. For comparison, the tumor volume was measured using the relative threshold method based on the maximum SUV (SUV max ). For the OSEM and TOF models, the mean %VD values were -0.06 ± 8.07 and -2.04 ± 4.23% for the fixed 40% threshold according to the SUV max and the SUV peak, respectively. The effect of our method in this case seemed to be minor. For the OSEM and PSF models, the mean %VD values were -20.41 ± 14.47 and -13.87 ± 6.59% for the fixed 40% threshold according to the SUV max and SUV peak , respectively. Our new method enabled the measurement of tumor volume with a fixed threshold and reduced the influence of the changes in tumor volume associated with the reconstruction model.
Ashley, Kevin; Brisson, Michael J; Howe, Alan M; Bartley, David L
2009-12-01
A collaborative interlaboratory evaluation of a newly standardized inductively coupled plasma mass spectrometry (ICP-MS) method for determining trace beryllium in workplace air samples was carried out toward fulfillment of method validation requirements for ASTM International voluntary consensus standard test methods. The interlaboratory study (ILS) was performed in accordance with an applicable ASTM International standard practice, ASTM E691, which describes statistical procedures for investigating interlaboratory precision. Uncertainty was also estimated in accordance with ASTM D7440, which applies the International Organization for Standardization Guide to the Expression of Uncertainty in Measurement to air quality measurements. Performance evaluation materials (PEMs) used consisted of 37 mm diameter mixed cellulose ester filters that were spiked with beryllium at levels of 0.025 (low loading), 0.5 (medium loading), and 10 (high loading) microg Be/filter; these spiked filters were prepared by a contract laboratory. Participating laboratories were recruited from a pool of over 50 invitees; ultimately, 20 laboratories from Europe, North America, and Asia submitted ILS results. Triplicates of each PEM (blanks plus the three different loading levels) were conveyed to each volunteer laboratory, along with a copy of the draft standard test method that each participant was asked to follow; spiking levels were unknown to the participants. The laboratories were requested to prepare the PEMs by one of three sample preparation procedures (hotplate or microwave digestion or hotblock extraction) that were described in the draft standard. Participants were then asked to analyze aliquots of the prepared samples by ICP-MS and to report their data in units of mu g Be/filter sample. Interlaboratory precision estimates from participating laboratories, computed in accordance with ASTM E691, were 0.165, 0.108, and 0.151 (relative standard deviation) for the PEMs spiked at 0.025, 0.5, and 10 microg Be/filter, respectively. Overall recoveries were 93.2%, 102%, and 80.6% for the low, medium, and high beryllium loadings, respectively. Expanded uncertainty estimates for interlaboratory analysis of low, medium, and high beryllium loadings, calculated in accordance with ASTM D7440, were 18.8%, 19.8%, and 24.4%, respectively. These figures of merit support promulgation of the analytical procedure as an ASTM International standard test method, ASTM D7439.
Private Animal Welfare Standards—Opportunities and Risks
Röcklinsberg, Helena
2018-01-01
Simple Summary In all European countries, farmers keeping animals must comply with European and national animal welfare legislation. Each government has a responsibility to make sure that the legislation is complied with by the farmers. However, during the last decades it has become increasingly common that private organisations, such as the industry, farmers’ organisations, or animal welfare organisations, develop additional animal welfare regulations (‘private standards’) that the farmers also need to comply with. These private standards have the opportunity to improve animal welfare above the legislative level, however, in our study we have shown that this is not always the case and that all of these different private standards, in addition to the legislation, makes it difficult to get an overview of the animal welfare regulation and control arena. For the sake of the farmers, the animal welfare inspectors, the consumers, and the animals we conclude that it is important that policymakers consider this arena as a whole and not their own regulation as a single phenomenon. Abstract The current shift moves the governance of animal welfare away from the government towards the private market and the consumers. We have studied the intentions, content, and on-farm inspection results from different sets of animal welfare legislation and private standards with an aim to highlight the most important opportunities and risks identified in relation to the trend of increasingly relying on private standards for safeguarding or improving farm animal welfare. Our results show that different focuses, intentions, animal welfare requirements, inspection methods (i.e., methods for measuring and evaluating the compliance with a regulation), and inspection results, together with the use of vague wordings and a drive towards more flexible regulations does certainly not facilitate the interpretation and implementation of animal welfare regulations, especially not in relation to each other. Since farmers today often have to comply with several animal welfare regulations, including private standards, it is important to stress that a given regulation should never be seen as a single, stand-alone phenomenon, and the policymakers must hence consider the bigger picture, and apply the standards in relation to other existing regulations. This is especially relevant in relation to the legislation, a level that a private standard can never ignore. PMID:29301279
Valkenborg, Dirk; Baggerman, Geert; Vanaerschot, Manu; Witters, Erwin; Dujardin, Jean-Claude; Burzykowski, Tomasz; Berg, Maya
2013-01-01
Abstract Combining liquid chromatography-mass spectrometry (LC-MS)-based metabolomics experiments that were collected over a long period of time remains problematic due to systematic variability between LC-MS measurements. Until now, most normalization methods for LC-MS data are model-driven, based on internal standards or intermediate quality control runs, where an external model is extrapolated to the dataset of interest. In the first part of this article, we evaluate several existing data-driven normalization approaches on LC-MS metabolomics experiments, which do not require the use of internal standards. According to variability measures, each normalization method performs relatively well, showing that the use of any normalization method will greatly improve data-analysis originating from multiple experimental runs. In the second part, we apply cyclic-Loess normalization to a Leishmania sample. This normalization method allows the removal of systematic variability between two measurement blocks over time and maintains the differential metabolites. In conclusion, normalization allows for pooling datasets from different measurement blocks over time and increases the statistical power of the analysis, hence paving the way to increase the scale of LC-MS metabolomics experiments. From our investigation, we recommend data-driven normalization methods over model-driven normalization methods, if only a few internal standards were used. Moreover, data-driven normalization methods are the best option to normalize datasets from untargeted LC-MS experiments. PMID:23808607
A Comparison of Three Types of Test Development Procedures Using Classical and Latent Trait Methods.
ERIC Educational Resources Information Center
Benson, Jeri; Wilson, Michael
Three methods of item selection were used to select sets of 38 items from a 50-item verbal analogies test and the resulting item sets were compared for internal consistency, standard errors of measurement, item difficulty, biserial item-test correlations, and relative efficiency. Three groups of 1,500 cases each were used for item selection. First…
Bioelectrochemical Systems Workshop:Standardized Analyses, Design Benchmarks, and Reporting
2012-01-01
related to the exoelectrogenic biofilm activity, and to investigate whether the community structure is a function of design and operational parameters...where should biofilm samples be collected? The most prevalent methods of community characterization in BES studies have entailed phylogenetic ...of function associated with this genetic marker, and in methods that involve polymerase chain reaction (PCR) amplification the quantitative
Sulfuric acid/hydrogen peroxide digestion and colorimetric a collaborative study.
Christians, D K; Aspelund, T G; Brayton, S V; Roberts, L L
1991-01-01
Seven laboratories participated in a collaborative study of a method for determination of phosphorus in meat and meat products. Samples are digested in sulfuric acid and hydrogen peroxide; digestion is complete in approximately 10 min. Phosphorus is determined by colorimetric analysis of a dilute aliquot of the sample digest. The collaborators analyzed 3 sets of blind duplicate samples from each of 6 classes of meat (U.S. Department of Agriculture classifications): smoked ham, water-added ham, canned ham, pork sausage, cooked sausage, and hamburger. The calibration curve was linear over the range of standard solutions prepared (phosphorus levels from 0.05 to 1.00%); levels in the collaborative study samples ranged from 0.10 to 0.30%. Standard deviations for repeatability (sr) and reproducibility (SR) ranged from 0.004 to 0.012 and 0.007 to 0.014, respectively. Corresponding relative standard deviations (RSDr and RSDR, respectively) ranged from 1.70 to 7.28% and 3.50 to 9.87%. Six laboratories analyzed samples by both the proposed method and AOAC method 24.016 (14th Ed.). One laboratory reported results by the proposed method only. Statistical evaluations indicated no significant difference between the 2 methods. The method has been adopted official first action by AOAC.
Predicting the accuracy of ligand overlay methods with Random Forest models.
Nandigam, Ravi K; Evans, David A; Erickson, Jon A; Kim, Sangtae; Sutherland, Jeffrey J
2008-12-01
The accuracy of binding mode prediction using standard molecular overlay methods (ROCS, FlexS, Phase, and FieldCompare) is studied. Previous work has shown that simple decision tree modeling can be used to improve accuracy by selection of the best overlay template. This concept is extended to the use of Random Forest (RF) modeling for template and algorithm selection. An extensive data set of 815 ligand-bound X-ray structures representing 5 gene families was used for generating ca. 70,000 overlays using four programs. RF models, trained using standard measures of ligand and protein similarity and Lipinski-related descriptors, are used for automatically selecting the reference ligand and overlay method maximizing the probability of reproducing the overlay deduced from X-ray structures (i.e., using rmsd < or = 2 A as the criteria for success). RF model scores are highly predictive of overlay accuracy, and their use in template and method selection produces correct overlays in 57% of cases for 349 overlay ligands not used for training RF models. The inclusion in the models of protein sequence similarity enables the use of templates bound to related protein structures, yielding useful results even for proteins having no available X-ray structures.
Ning, Xun-An; Zhou, Yun; Liu, Jing-Yong; Wang, Jiang-Hui; Li, Lei; Ma, Xiao-Guo
2011-09-01
A method of microwave digestion technique-flame atomic absorption spectrometry was proposed to determine the total contents of Cu, Zn, Pb, Cd, Cr and Ni in five different kinds of waste bag filters from a steel plant. The digestion effects of the six acid systems on the heavy metals digestion were studied for the first time. The relative standard deviation (RSD) of the method was between 1.02% and 9.35%, and the recovery rates obtained by standard addition method ranged from 87.7% to 105.6%. The results indicated that the proposed method exhibited the advantages of simplicity, speediness, accuracy and repeatability, and it was suitable for determining the metal elements of the waste bag filter. The results also showed that different digestion systems should be used according to different waste bag filters. The waste bag filter samples from different production processes had different metal elements content. The Pb and Zn were the highest in the waste bag filters, while the Cu, Ni, Cd and Cr were relatively lower. These determination results provided the scientific data for further treatment and disposal of the waste bag filter.
Development of duplex real-time PCR for the detection of WSSV and PstDV1 in cultivated shrimp.
Leal, Carlos A G; Carvalho, Alex F; Leite, Rômulo C; Figueiredo, Henrique C P
2014-07-05
The White spot syndrome virus (WSSV) and Penaeus stylirostris penstyldensovirus 1 (previously named Infectious hypodermal and hematopoietic necrosis virus-IHHNV) are two of the most important viral pathogens of penaeid shrimp. Different methods have been applied for diagnosis of these viruses, including Real-time PCR (qPCR) assays. A duplex qPCR method allows the simultaneous detection of two viruses in the same sample, which is more cost-effective than assaying for each virus separately. Currently, an assay for the simultaneous detection of the WSSV and the PstDV1 in shrimp is unavailable. The aim of this study was to develop and standardize a duplex qPCR assay for the simultaneous detection of the WSSV and the PstDV1 in clinical samples of diseased L. vannamei. In addition, to evaluate the performance of two qPCR master mixes with regard to the clinical sensitivity of the qPCR assay, as well as, different methods for qPCR results evaluation. The duplex qPCR assay for detecting WSSV and PstDV1 in clinical samples was successfully standardized. No difference in the amplification of the standard curves was observed between the duplex and singleplex assays. Specificities and sensitivities similar to those of the singleplex assays were obtained using the optimized duplex qPCR. The analytical sensitivities of duplex qPCR were two copies of WSSV control plasmid and 20 copies of PstDV1 control plasmid. The standardized duplex qPCR confirmed the presence of viral DNA in 28 from 43 samples tested. There was no difference for WSSV detection using the two kits and the distinct methods for qPCR results evaluation. High clinical sensitivity for PstDV1 was obtained with TaqMan Universal Master Mix associated with relative threshold evaluation. Three cases of simultaneous infection by the WSSV and the PstDV1 were identified with duplex qPCR. The standardized duplex qPCR was shown to be a robust, highly sensitive, and feasible diagnostic tool for the simultaneous detection of the WSSV and the PstDV1 in whiteleg shrimp. The use of the TaqMan Universal Master Mix and the relative threshold method of data analysis in our duplex qPCR method provided optimal levels of sensitivity and specificity.
Validation of lignocellulosic biomass carbohydrates determination via acid hydrolysis.
Zhou, Shengfei; Runge, Troy M
2014-11-04
This work studied the two-step acid hydrolysis for determining carbohydrates in lignocellulosic biomass. Estimation of sugar loss based on acid hydrolyzed sugar standards or analysis of sugar derivatives was investigated. Four model substrates (starch, holocellulose, filter paper and cotton) and three levels of acid/material ratios (7.8, 10.3 and 15.4, v/w) were studied to demonstrate the range of test artifacts. The method for carbohydrates estimation based on acid hydrolyzed sugar standards having the most satisfactory carbohydrate recovery and relative standard deviation. Raw material and the acid/material ratio both had significant effect on carbohydrate hydrolysis, suggesting the acid to have impacts beyond a catalyst in the hydrolysis. Following optimal procedures, we were able to reach a carbohydrate recovery of 96% with a relative standard deviation less than 3%. The carbohydrates recovery lower than 100% was likely due to the incomplete hydrolysis of substrates, which was supported by scanning electron microscope (SEM) images. Copyright © 2014 Elsevier Ltd. All rights reserved.
Characterizing Vaccinium berry Standard Reference Materials by GC-MS using NIST spectral libraries.
Lowenthal, Mark S; Andriamaharavo, Nirina R; Stein, Stephen E; Phinney, Karen W
2013-05-01
A gas chromatography-mass spectrometry (GC-MS)-based method was developed for qualitative characterization of metabolites found in Vaccinium fruit (berry) dietary supplement Standard Reference Materials (SRMs). Definitive identifications are provided for 98 unique metabolites determined among six Vaccinium-related SRMs. Metabolites were enriched using an organic liquid/liquid extraction, and derivatized prior to GC-MS analysis. Electron ionization (EI) fragmentation spectra were searched against EI spectra of authentic standards compiled in the National Institute of Standards and Technology's mass spectral libraries, as well as spectra selected from the literature. Metabolite identifications were further validated using a retention index match along with prior probabilities and were compared with results obtained in a previous effort using collision-induced dissociation (CID) MS/MS datasets from liquid chromatography coupled to mass spectrometry experiments. This manuscript describes a nontargeted metabolite profile of Vaccinium materials, compares results among related materials and from orthogonal experimental platforms, and discusses the feasibility and development of using mass spectral library matching for nontargeted metabolite identification.
Review of methods for handling confounding by cluster and informative cluster size in clustered data
Seaman, Shaun; Pavlou, Menelaos; Copas, Andrew
2014-01-01
Clustered data are common in medical research. Typically, one is interested in a regression model for the association between an outcome and covariates. Two complications that can arise when analysing clustered data are informative cluster size (ICS) and confounding by cluster (CBC). ICS and CBC mean that the outcome of a member given its covariates is associated with, respectively, the number of members in the cluster and the covariate values of other members in the cluster. Standard generalised linear mixed models for cluster-specific inference and standard generalised estimating equations for population-average inference assume, in general, the absence of ICS and CBC. Modifications of these approaches have been proposed to account for CBC or ICS. This article is a review of these methods. We express their assumptions in a common format, thus providing greater clarity about the assumptions that methods proposed for handling CBC make about ICS and vice versa, and about when different methods can be used in practice. We report relative efficiencies of methods where available, describe how methods are related, identify a previously unreported equivalence between two key methods, and propose some simple additional methods. Unnecessarily using a method that allows for ICS/CBC has an efficiency cost when ICS and CBC are absent. We review tools for identifying ICS/CBC. A strategy for analysis when CBC and ICS are suspected is demonstrated by examining the association between socio-economic deprivation and preterm neonatal death in Scotland. PMID:25087978
Gang, Wei-juan; Wang, Xin; Wang, Fang; Dong, Guo-feng; Wu, Xiao-dong
2015-08-01
The national standard of "Regulations of Acupuncture-needle Manipulating Techniques" is one of the national Criteria of Acupuncturology for which a total of 22 items have been already established. In the process of formulation, a series of common and specific problems have been met. In the present paper, the authors expound these problems from 3 aspects, namely principles for formulation, methods for formulating criteria, and considerations about some problems. The formulating principles include selection and regulations of principles for technique classification and technique-related key factors. The main methods for formulating criteria are 1) taking the literature as the theoretical foundation, 2) taking the clinical practice as the supporting evidence, and 3) taking the expounded suggestions or conclusions through peer review.
[Research progress on mechanical performance evaluation of artificial intervertebral disc].
Li, Rui; Wang, Song; Liao, Zhenhua; Liu, Weiqiang
2018-03-01
The mechanical properties of artificial intervertebral disc (AID) are related to long-term reliability of prosthesis. There are three testing methods involved in the mechanical performance evaluation of AID based on different tools: the testing method using mechanical simulator, in vitro specimen testing method and finite element analysis method. In this study, the testing standard, testing equipment and materials of AID were firstly introduced. Then, the present status of AID static mechanical properties test (static axial compression, static axial compression-shear), dynamic mechanical properties test (dynamic axial compression, dynamic axial compression-shear), creep and stress relaxation test, device pushout test, core pushout test, subsidence test, etc. were focused on. The experimental techniques using in vitro specimen testing method and testing results of available artificial discs were summarized. The experimental methods and research status of finite element analysis were also summarized. Finally, the research trends of AID mechanical performance evaluation were forecasted. The simulator, load, dynamic cycle, motion mode, specimen and test standard would be important research fields in the future.
Dykes, Patricia C; Wantland, Dean; Whittenburg, Luann; Lipsitz, Stuart; Saba, Virginia K
2013-01-01
While nursing activities represent a significant proportion of inpatient care, there are no reliable methods for determining nursing costs based on the actual services provided by the nursing staff. Capture of data to support accurate measurement and reporting on the cost of nursing services is fundamental to effective resource utilization. Adopting standard terminologies that support tracking both the quality and the cost of care could reduce the data entry burden on direct care providers. This pilot study evaluated the feasibility of using a standardized nursing terminology, the Clinical Care Classification System (CCC), for developing a reliable costing method for nursing services. Two different approaches are explored; the Relative Value Unit RVU and the simple cost-to-time methods. We found that the simple cost-to-time method was more accurate and more transparent in its derivation than the RVU method and may support a more consistent and reliable approach for costing nursing services.
Lipscomb, Hester J; Li, Leiming; Dement, John
2003-08-01
Washington State enacted a change in their fall standard for the construction industry in 1991, preceding the Safety Standard for Fall Protection in the Construction Industry promulgated by Federal OSHA in 1994. We evaluated changes in the rate of falls from elevations and measures of severity among a large cohort of union carpenters after the fall standard change in Washington State, taking into account the temporal trends in their overall injury rates. There was a significant decrease in the rate of falls from height after the standard went into effect, even after adjusting for the overall decrease in work-related injuries among this cohort. Much of the decrease was immediate, likely representing the publicity surrounding fatal falls and subsequent promulgation of the standard. The greatest decrease was seen between 3 and 3(1/2) years after the standard went into effect. There was a significant reduction in mean paid lost days per event after the standard change and there was a significant reduction in mean cost per fall when adjusting for age and the temporal trend for costs among non-fall injuries. Through the use of observational methods we have demonstrated significant effects of the Washington State Vertical Fall Arrest Standard among carpenters in the absence of a control or comparison group. Without controlling for the temporal trend in overall injury rates, the rate of decline in falls appeared significantly greater, but the more pronounced, but delayed, decline was not seen. The analyses demonstrate potential error in failing to account for temporal patterns or assuming that a decline after an intervention is related to the intervention. Copyright 2003 Wiley-Liss, Inc.
Measurement of Antenna Bore-Sight Gain
NASA Technical Reports Server (NTRS)
Fortinberry, Jarrod; Shumpert, Thomas
2016-01-01
The absolute or free-field gain of a simple antenna can be approximated using standard antenna theory formulae or for a more accurate prediction, numerical methods may be employed to solve for antenna parameters including gain. Both of these methods will result in relatively reasonable estimates but in practice antenna gain is usually verified and documented via measurements and calibration. In this paper, a relatively simple and low-cost, yet effective means of determining the bore-sight free-field gain of a VHF/UHF antenna is proposed by using the Brewster angle relationship.
Theoretical Study of Watershed Eco-Compensation Standards
NASA Astrophysics Data System (ADS)
Yan, Dandan; Fu, Yicheng; Liu, Biu; Sha, Jinxia
2018-01-01
Watershed eco-compensation is an effective way to solve conflicts over water allocation and ecological destruction problems in the exploitation of water resources. Despite an increasing interest in the topic, the researches has neglected the effect of water quality and lacked systematic calculation method. In this study we reviewed and analyzed the current literature and proposedatheoretical framework to improve the calculation of co-compensation standard.Considering the perspectives of the river ecosystems, forest ecosystems and wetland ecosystems, the benefit compensation standard was determined by the input-output corresponding relationship. Based on the opportunity costs related to limiting development and water conservation loss, the eco-compensation standard was calculated.In order to eliminate the defects of eco-compensation implementation, the improvement suggestions were proposed for the compensation standard calculation and implementation.
The impact of Life Science Identifier on informatics data.
Martin, Sean; Hohman, Moses M; Liefeld, Ted
2005-11-15
Since the Life Science Identifier (LSID) data identification and access standard made its official debut in late 2004, several organizations have begun to use LSIDs to simplify the methods used to uniquely name, reference and retrieve distributed data objects and concepts. In this review, the authors build on introductory work that describes the LSID standard by documenting how five early adopters have incorporated the standard into their technology infrastructure and by outlining several common misconceptions and difficulties related to LSID use, including the impact of the byte identity requirement for LSID-identified objects and the opacity recommendation for use of the LSID syntax. The review describes several shortcomings of the LSID standard, such as the lack of a specific metadata standard, along with solutions that could be addressed in future revisions of the specification.
Zhao, Yanyan; Liu, Liyan; Han, Yuanyuan; Li, Yueqiu; Wang, Yan; Shi, Minjian
2013-09-01
An analytical method for the simultaneous determination of 18alpha-glycyrrhizic acid, 18beta-glycyrrhizinic acid, related substances A and B and drug quality standard by reversed-phase high performance liquid chromatography (RP-HPLC) was established. The assay was carried out on a Durashell-C18 column (250 mm x 4.6 mm, 5 microm) with 10 mmol/L ammonium perchlorate (the pH value was adjusted to 8.20 with ammonia)-methanol (48:52, v/v) as mobile phase at a flow rate of 0.80 mL/min, and the detection wavelength was set at 254 nm. The column temperature was 50 degrees C and the injection volume was 10 microL. Under the separation conditions, the calibration curves of the analytes showed good linearities within the mass concentrations of 0.50 -100 mg/L (r > 0.999 9). The detection limits for 18alpha-glycyrrhizic acid, 18beta-glycyrrhizinic acid, related substances A and B were 0.15, 0.10, 0.10, 0.15 mg/L, respectively. The average recoveries were between 97.32% and 99.33% (n = 3) with the relative standard deviations (RSDs) between 0.05% and 1.06%. The method is sensitive, reproducible, and the results are accurate and reliable. The method can be used for the determination of principal components and related substances of ammonium glycyrrhizinate for the quality control of raw material drug of ammonium glycyrrhizinate.
Grate, Jay W; Gonzalez, Jhanis J; O'Hara, Matthew J; Kellogg, Cynthia M; Morrison, Samuel S; Koppenaal, David W; Chan, George C-Y; Mao, Xianglei; Zorba, Vassilia; Russo, Richard E
2017-09-08
Solid sampling and analysis methods, such as laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS), are challenged by matrix effects and calibration difficulties. Matrix-matched standards for external calibration are seldom available and it is difficult to distribute spikes evenly into a solid matrix as internal standards. While isotopic ratios of the same element can be measured to high precision, matrix-dependent effects in the sampling and analysis process frustrate accurate quantification and elemental ratio determinations. Here we introduce a potentially general solid matrix transformation approach entailing chemical reactions in molten ammonium bifluoride (ABF) salt that enables the introduction of spikes as tracers or internal standards. Proof of principle experiments show that the decomposition of uranium ore in sealed PFA fluoropolymer vials at 230 °C yields, after cooling, new solids suitable for direct solid sampling by LA. When spikes are included in the molten salt reaction, subsequent LA-ICP-MS sampling at several spots indicate that the spikes are evenly distributed, and that U-235 tracer dramatically improves reproducibility in U-238 analysis. Precisions improved from 17% relative standard deviation for U-238 signals to 0.1% for the ratio of sample U-238 to spiked U-235, a factor of over two orders of magnitude. These results introduce the concept of solid matrix transformation (SMT) using ABF, and provide proof of principle for a new method of incorporating internal standards into a solid for LA-ICP-MS. This new approach, SMT-LA-ICP-MS, provides opportunities to improve calibration and quantification in solids based analysis. Looking forward, tracer addition to transformed solids opens up LA-based methods to analytical methodologies such as standard addition, isotope dilution, preparation of matrix-matched solid standards, external calibration, and monitoring instrument drift against external calibration standards.
NASA Astrophysics Data System (ADS)
Muir, B. R.; McEwen, M. R.; Rogers, D. W. O.
2014-10-01
A method is presented to obtain ion chamber calibration coefficients relative to secondary standard reference chambers in electron beams using depth-ionization measurements. Results are obtained as a function of depth and average electron energy at depth in 4, 8, 12 and 18 MeV electron beams from the NRC Elekta Precise linac. The PTW Roos, Scanditronix NACP-02, PTW Advanced Markus and NE 2571 ion chambers are investigated. The challenges and limitations of the method are discussed. The proposed method produces useful data at shallow depths. At depths past the reference depth, small shifts in positioning or drifts in the incident beam energy affect the results, thereby providing a built-in test of incident electron energy drifts and/or chamber set-up. Polarity corrections for ion chambers as a function of average electron energy at depth agree with literature data. The proposed method produces results consistent with those obtained using the conventional calibration procedure while gaining much more information about the behavior of the ion chamber with similar data acquisition time. Measurement uncertainties in calibration coefficients obtained with this method are estimated to be less than 0.5%. These results open up the possibility of using depth-ionization measurements to yield chamber ratios which may be suitable for primary standards-level dissemination.
Establishing pass/fail criteria for bronchoscopy performance.
Konge, Lars; Clementsen, Paul; Larsen, Klaus Richter; Arendrup, Henrik; Buchwald, Christian; Ringsted, Charlotte
2012-01-01
Several tools have been created to assess competence in bronchoscopy. However, educational guidelines still use an arbitrary number of performed procedures to decide when basic competency is acquired. The purpose of this study was to define pass/fail scores for two bronchoscopy assessment tools, and investigate how these scores relate to physicians' experience regarding the number of bronchoscopy procedures performed. We studied two assessment tools and used two standard setting methods to create cut scores: the contrasting-groups method and the extended Angoff method. In the first we compared bronchoscopy performance scores of 14 novices with the scores of 14 experienced consultants to find the score that best discriminated between the two groups. In the second we asked an expert group of 7 experienced bronchoscopists to judge how a borderline trainee would perform on each item of the test. Using the contrasting-groups method we found a standard that would fail all novices and pass all consultants. A clear pass related to prior experience of 75 procedures. The consequences of using the extended Angoff method were also acceptable: all trainees who had performed less than 50 bronchoscopies failed the test and all consultants passed. A clear pass related to 80 procedures. Our proposed pass/fail scores for these two methods seem appropriate in terms of consequences. Prior experience with the performance of 75 and 80 bronchoscopies, respectively, seemed to ensure basic competency. In the future objective assessment tools could become an important aid in the certification of physicians performing bronchoscopies. Copyright © 2011 S. Karger AG, Basel.
Zhou, Tianyu; Ding, Jie; Wang, Qiang; Xu, Yuan; Wang, Bo; Zhao, Li; Ding, Hong; Chen, Yanhua; Ding, Lan
2018-03-01
Monodisperse superhydrophilic melamine formaldehyde resorcinol resin (MFR) microspheres were prepared in 90min at 85°C via a microwave-assisted method with a yield of 60.6%. The obtained MFR microspheres exhibited narrow size distribution with the average particle size of about 2.5µm. The MFR microspheres were used as absorbents to detect triazines in juices followed by high performance liquid chromatography tandem mass spectrometry. Various factors affecting the extraction efficiency were investigated. Under the optimized conditions, the built method exhibited excellent linearity in the range of 1-250μgL -1 (R 2 ≥ 0.9994) and lower detection limits (0.3-0.65μgL -1 ). The relative standard deviations of intra- and inter-day analyses ranged from 3% to 7% and from 2% to 7%, respectively. The method was applied to determine six triazines in three juice samples. At the spiked level of 3μgL -1 , the recoveries were in the range of 90-99% with the relative standard deviations ≤ 8%. Copyright © 2017 Elsevier B.V. All rights reserved.
Fiamegkos, I; Cordeiro, F; Robouch, P; Vélez, D; Devesa, V; Raber, G; Sloth, J J; Rasmussen, R R; Llorente-Mirandes, T; Lopez-Sanchez, J F; Rubio, R; Cubadda, F; D'Amato, M; Feldmann, J; Raab, A; Emteborg, H; de la Calle, M B
2016-12-15
A collaborative trial was conducted to determine the performance characteristics of an analytical method for the quantification of inorganic arsenic (iAs) in food. The method is based on (i) solubilisation of the protein matrix with concentrated hydrochloric acid to denature proteins and allow the release of all arsenic species into solution, and (ii) subsequent extraction of the inorganic arsenic present in the acid medium using chloroform followed by back-extraction to acidic medium. The final detection and quantification is done by flow injection hydride generation atomic absorption spectrometry (FI-HG-AAS). The seven test items used in this exercise were reference materials covering a broad range of matrices: mussels, cabbage, seaweed (hijiki), fish protein, rice, wheat, mushrooms, with concentrations ranging from 0.074 to 7.55mgkg(-1). The relative standard deviation for repeatability (RSDr) ranged from 4.1 to 10.3%, while the relative standard deviation for reproducibility (RSDR) ranged from 6.1 to 22.8%. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.
McCleary, Barry V; McNally, Marian; Rossiter, Patricia
2002-01-01
Interlaboratory performance statistics was determined for a method developed to measure the resistant starch (RS) content of selected plant food products and a range of commercial starch samples. Food materials examined contained RS (cooked kidney beans, green banana, and corn flakes) and commercial starches, most of which naturally contain, or were processed to yield, elevated RS levels. The method evaluated was optimized to yield RS values in agreement with those reported for in vivo studies. Thirty-seven laboratories tested 8 pairs of blind duplicate starch or plant material samples with RS values between 0.6 (regular maize starch) and 64% (fresh weight basis). For matrixes excluding regular maize starch, repeatability relative standard deviation (RSDr) values ranged from 1.97 to 4.2%, and reproducibility relative standard deviation (RSDR) values ranged from 4.58 to 10.9%. The range of applicability of the test is 2-64% RS. The method is not suitable for products with <1% RS (e.g., regular maize starch; 0.6% RS). For such products, RSDr and RSDR values are unacceptably high.
Dai, Qing-Yan; Gao, Qiang; Wu, Chun-Sheng; Chesters, Douglas; Zhu, Chao-Dong; Zhang, Ai-Bing
2012-01-01
Unlike distinct species, closely related species offer a great challenge for phylogeny reconstruction and species identification with DNA barcoding due to their often overlapping genetic variation. We tested a sibling species group of pine moth pests in China with a standard cytochrome c oxidase subunit I (COI) gene and two alternative internal transcribed spacer (ITS) genes (ITS1 and ITS2). Five different phylogenetic/DNA barcoding analysis methods (Maximum likelihood (ML)/Neighbor-joining (NJ), “best close match” (BCM), Minimum distance (MD), and BP-based method (BP)), representing commonly used methodology (tree-based and non-tree based) in the field, were applied to both single-gene and multiple-gene analyses. Our results demonstrated clear reciprocal species monophyly for three relatively distant related species, Dendrolimus superans, D. houi, D. kikuchii, as recovered by both single and multiple genes while the phylogenetic relationship of three closely related species, D. punctatus, D. tabulaeformis, D. spectabilis, could not be resolved with the traditional tree-building methods. Additionally, we find the standard COI barcode outperforms two nuclear ITS genes, whatever the methods used. On average, the COI barcode achieved a success rate of 94.10–97.40%, while ITS1 and ITS2 obtained a success rate of 64.70–81.60%, indicating ITS genes are less suitable for species identification in this case. We propose the use of an overall success rate of species identification that takes both sequencing success and assignation success into account, since species identification success rates with multiple-gene barcoding system were generally overestimated, especially by tree-based methods, where only successfully sequenced DNA sequences were used to construct a phylogenetic tree. Non-tree based methods, such as MD, BCM, and BP approaches, presented advantages over tree-based methods by reporting the overall success rates with statistical significance. In addition, our results indicate that the most closely related species D. punctatus, D. tabulaeformis, and D. spectabilis, may be still in the process of incomplete lineage sorting, with occasional hybridizations occurring among them. PMID:22509245
Interagency comparison of iodometric methods for ozone determination
NASA Technical Reports Server (NTRS)
Demore, W. B.; Romanovsky, J. C.; Feldstein, M.; Mueller, P. K.; Hamming, W. J.
1976-01-01
The California Air Resources Board appointed an Oxidant Calibration Committee for the purpose of evaluating the accuracy of the different agency calibration procedures. The committee chose UV absorption photometry as the reference method for ozone measurement. Interagency comparisons of the various iodometric methods were conducted relative to the ultraviolet standard. The tests included versions of the iodometric methods as employed by the Air Resources Board, the Los Angeles Air Pollution Control District, and the EPA. An alternative candidate reference method for ozone measurement, gas phase titration, was also included in the test series.
Yang, X; Yang, Y; Zhou, R; Bian, L
2001-11-01
For studying the contents of dietary fiber in general foods and functional foods, a enzymatic-gravimetric method recommended by AOAC was established in our laboratory. The method for the determination of total, soluble and insoluble dietary fiber in foods and functional foods could be used for many other kind of foods. The relative standard deviations (RSD) of reproducibility between-run and within-run were 2.04%-7.85%, 3.42%-55.23% respectively. The repeatability of the methods was good, and the methods are suitable for many foods.
The purpose of this SOP is to describe the procedures for using and maintaining the related microcomputer equipment at the Illinois Institute of Technology (IIT)/NHEXAS site. These methods were used in all data operations and maintenance routines during the Arizona NHEXAS projec...
The purpose of this SOP is to describe procedures for using and maintaining the local area network (LAN) and related microcomputer equipment at the HRP Site of the Arizona Prevention Center. These methods were used for all data operations and maintenance routines during the Ariz...
Technical Note: Some Issues Related to the Selection of Polymers for Aerospace Oxygen Systems
NASA Technical Reports Server (NTRS)
Hirsch, David; Beeson, Harold
2004-01-01
Materials intended for use in aerospace oxygen systems are commonly screened for oxygen compatibility following NASA STD 6001. This standard allows qualification of materials based on results provided by only one test method. Potential issues related to this practice are reviewed and recommendations are proposed that would lead to improved aerospace oxygen systems safety.
A deviation display method for visualising data in mobile gamma-ray spectrometry.
Kock, Peder; Finck, Robert R; Nilsson, Jonas M C; Ostlund, Karl; Samuelsson, Christer
2010-09-01
A real time visualisation method, to be used in mobile gamma-spectrometric search operations using standard detector systems is presented. The new method, called deviation display, uses a modified waterfall display to present relative changes in spectral data over energy and time. Using unshielded (137)Cs and (241)Am point sources and different natural background environments, the behaviour of the deviation displays is demonstrated and analysed for two standard detector types (NaI(Tl) and HPGe). The deviation display enhances positive significant changes while suppressing the natural background fluctuations. After an initialization time of about 10min this technique leads to a homogeneous display dominated by the background colour, where even small changes in spectral data are easy to discover. As this paper shows, the deviation display method works well for all tested gamma energies and natural background radiation levels and with both tested detector systems.
Fu, Hongbo; Wang, Huadong; Jia, Junwei; Ni, Zhibo; Dong, Fengzhong
2018-01-01
Due to the influence of major elements' self-absorption, scarce observable spectral lines of trace elements, and relative efficiency correction of experimental system, accurate quantitative analysis with calibration-free laser-induced breakdown spectroscopy (CF-LIBS) is in fact not easy. In order to overcome these difficulties, standard reference line (SRL) combined with one-point calibration (OPC) is used to analyze six elements in three stainless-steel and five heat-resistant steel samples. The Stark broadening and Saha - Boltzmann plot of Fe are used to calculate the electron density and the plasma temperature, respectively. In the present work, we tested the original SRL method, the SRL with the OPC method, and intercept with the OPC method. The final calculation results show that the latter two methods can effectively improve the overall accuracy of quantitative analysis and the detection limits of trace elements.
Kong, Xianghong; He, Qiang; Yue, Aishan; Wu, Shuangmin; Li, Jianhua
2010-06-01
An ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/ MS) method was developed for the determination of arbutin in apple juice concentrate. Samples were diluted with water, then cleaned-up with a PS-DVB column. Quantitation was carried out using an external standard method. UPLC was performed on an Eclipse Plus C, column (100 mm x 2.1 mm, 1.8 microm) using a gradient solvent system (methanol-water). MS/MS was performed with multiple reaction monitoring (MRM) mode. The detection limit of arbutin was 0.02 mg/L. The method showed good linear relationship at the range of 0.04-2.0 mg/L. The recoveries ranged from 75.2% to 102.7% with relative standard deviations (RSDs) less than 8.9%. The method is simple, fast and sensitive. It's suitable for quantitative and qualitative analysis of arbutin in apple juice concentrate.
Miyashita, Shin-ichi; Inagaki, Kazumi; Narukawa, Tomohiro; Zhu, Yanbei; Kuroiwa, Takayoshi; Hioki, Akiharu; Chiba, Koichi
2012-01-01
A certified reference material (CRM) for trace cadmium and other elements in brown rice flour was developed at the National Metrology Institute of Japan (NMIJ). The CRM was provided as a dry powder after drying and frozen pulverization of fresh brown rice obtained from a Japanese domestic market. Characterization of the property value for each element was carried out exclusively by NMIJ with at least two independent analytical methods, including inductively coupled plasma mass spectrometry (ICP-MS), ICP high-resolution mass spectrometry, isotope-dilution ICP-MS, ICP optical emission spectrometry, and graphite-furnace atomic-absorption spectrometry. Property values were provided for six elements (Mn, Fe, Cu, Zn, As, and Cd). The concentration range of the property values was from 0.280 mg kg(-1) of As to 31.8 mg kg(-1) of Zn. The combined relative standard uncertainties of the property values were estimated by considering the uncertainties of the homogeneity, characterization, difference among analytical methods, dry-mass correction factor, and calibration standard. The range of the relative combined standard uncertainties was from 1.1% of Zn to 1.6% of As.
[Study on seed quality test and quality standard of Lonicera macranthoides].
Zhang, Ying; Xu, Jin; Li, Long-Yun; Cui, Guang-Lin; She, Yue-Hui
2016-04-01
Referring to the rules for agricultural seed testing (GB/T 3543-1995) issued by China, the test of sampling, purity, thousand seed weight, moisture, viability, relative conductivity and germination rate had been studied for seed quality test methods of Lonicera macranthoides. The seed quality from 38 different collection areas was measured to establish quality classification standard by K-means clustering. The results showed that at least 7.5 g seeds should be sampled, and passed 20-mesh sieve for purity analysis.The 500-seed method used to measure thousand seed weight. The moisture was determined by crushed seeds dried in high temperature (130±2) ℃ for 3 h.The viability determined by 25 ℃ 0.1% TTC stained 5h in dark. 1.0 g seeds soaked in 50 ml ultra pure water in 25 ℃ for 12 hours to determine the relative conductivity. The seed by 4 ℃stratification for 80 days were cultured on paper at 15 ℃. Quality of the seeds from different areas was divided into three grades. The primary seed quality classification standard was established.The I grade and II grade were recommend use in production. Copyright© by the Chinese Pharmaceutical Association.
Chen, Yong; Liu, Yulun; Ning, Jing; Cormier, Janice; Chu, Haitao
2014-01-01
Systematic reviews of diagnostic tests often involve a mixture of case-control and cohort studies. The standard methods for evaluating diagnostic accuracy only focus on sensitivity and specificity and ignore the information on disease prevalence contained in cohort studies. Consequently, such methods cannot provide estimates of measures related to disease prevalence, such as population averaged or overall positive and negative predictive values, which reflect the clinical utility of a diagnostic test. In this paper, we propose a hybrid approach that jointly models the disease prevalence along with the diagnostic test sensitivity and specificity in cohort studies, and the sensitivity and specificity in case-control studies. In order to overcome the potential computational difficulties in the standard full likelihood inference of the proposed hybrid model, we propose an alternative inference procedure based on the composite likelihood. Such composite likelihood based inference does not suffer computational problems and maintains high relative efficiency. In addition, it is more robust to model mis-specifications compared to the standard full likelihood inference. We apply our approach to a review of the performance of contemporary diagnostic imaging modalities for detecting metastases in patients with melanoma. PMID:25897179
Fontana, Ariel R; Patil, Sangram H; Banerjee, Kaushik; Altamirano, Jorgelina C
2010-04-28
A fast and effective microextraction technique is proposed for preconcentration of 2,4,6-trichloroanisole (2,4,6-TCA) from wine samples prior gas chromatography tandem mass spectrometric (GC-MS/MS) analysis. The proposed technique is based on ultrasonication (US) for favoring the emulsification phenomenon during the extraction stage. Several variables influencing the relative response of the target analyte were studied and optimized. Under optimal experimental conditions, 2,4,6-TCA was quantitatively extracted achieving enhancement factors (EF) > or = 400 and limits of detection (LODs) 0.6-0.7 ng L(-1) with relative standard deviations (RSDs) < or = 11.3%, when 10 ng L(-1) 2,4,6-TCA standard-wine sample blend was analyzed. The calibration graphs for white and red wine were linear within the range of 5-1000 ng L(-1), and estimation coefficients (r(2)) were > or = 0.9995. Validation of the methodology was carried out by standard addition method at two concentrations (10 and 50 ng L(-1)) achieving recoveries >80% indicating satisfactory robustness of the method. The methodology was successfully applied for determination of 2,4,6-TCA in different wine samples.
Shah, Reshma P.; Spruyt, Karen; Kragie, Brigette C.; Greeley, Siri Atma W.; Msall, Michael E.
2012-01-01
OBJECTIVE To assess performance on an age-standardized neuromotor coordination task among sulfonylurea-treated KCNJ11-related neonatal diabetic patients. RESEARCH DESIGN AND METHODS Nineteen children carrying KCNJ11 mutations associated with isolated diabetes (R201H; n = 8), diabetes with neurodevelopmental impairment (V59M or V59A [V59M/A]; n = 8), or diabetes not consistently associated with neurodevelopmental disability (Y330C, E322K, or R201C; n = 3) were studied using the age-standardized Beery-Buktenica Developmental Test of Visual-Motor Integration (VMI). RESULTS Although R201H subjects tested in the normal range (median standard score = 107), children with V59M/A mutations had significantly lower than expected VMI standard scores (median = 49). The scores for all three groups were significantly different from each other (P = 0.0017). The age of sulfonylurea initiation was inversely correlated with VMI scores in the V59M/A group (P < 0.05). CONCLUSIONS Neurodevelopmental disability in KCNJ11-related diabetes includes visuomotor problems that may be ameliorated by early sulfonylurea treatment. Comprehensive longitudinal assessment on larger samples will be imperative. PMID:22855734
A note on calculation of efficiency and emissions from wood and wood pellet stoves
NASA Astrophysics Data System (ADS)
Petrocelli, D.; Lezzi, A. M.
2015-11-01
In recent years, national laws and international regulations have introduced strict limits on efficiency and emissions from woody biomass appliances to promote the diffusion of models characterized by low emissions and high efficiency. The evaluation of efficiency and emissions is made during the certification process which consists in standardized tests. Standards prescribe the procedures to be followed during tests and the relations to be used to determine the mean value of efficiency and emissions. As a matter of fact these values are calculated using flue gas temperature and composition averaged over the whole test period, lasting from 1 to 6 hours. Typically, in wood appliances the fuel burning rate is not constant and this leads to a considerable variation in time of composition and flow rate of the flue gas. In this paper we show that this fact may cause significant differences between emission values calculated according to standards and those obtained integrating over the test period the instantaneous mass and energy balances. In addition, we propose some approximated relations and a method for wood stoves which supply more accurate results than those calculated according to standards. These relations can be easily implemented in a computer controlled data acquisition systems.
Comparison of two metrological approaches for the prediction of human haptic perception
NASA Astrophysics Data System (ADS)
Neumann, Annika; Frank, Daniel; Vondenhoff, Thomas; Schmitt, Robert
2016-06-01
Haptic perception is regarded as a key component of customer appreciation and acceptance for various products. The prediction of customers’ haptic perception is of interest both during product development and production phases. This paper presents the results of a multivariate analysis between perceived roughness and texture related surface measurements, to examine whether perceived roughness can be accurately predicted using technical measurements. Studies have shown that standardized measurement parameters, such as the roughness coefficients (e.g. Rz or Ra), do not show a one-dimensional linear correlation with the human perception (of roughness). Thus, an alternative measurement method was compared to standard measurements of roughness, in regard to its capability of predicting perceived roughness through technical measurements. To estimate perceived roughness, an experimental study was conducted in which 102 subjects evaluated four sets of 12 different geometrical surface structures regarding their relative perceived roughness. The two different metrological procedures were examined in relation to their capability to predict the perceived roughness of the subjects stated within the study. The standardized measurements of the surface roughness were made using a structured light 3D-scanner. As an alternative method, surface induced vibrations were measured by a finger-like sensor during robot-controlled traverse over a surface. The presented findings provide a better understanding of the predictability of human haptic perception using technical measurements.
A Fresh Start for Flood Estimation in Ungauged Basins
NASA Astrophysics Data System (ADS)
Woods, R. A.
2017-12-01
The two standard methods for flood estimation in ungauged basins, regression-based statistical models and rainfall-runoff models using a design rainfall event, have survived relatively unchanged as the methods of choice for more than 40 years. Their technical implementation has developed greatly, but the models' representation of hydrological processes has not, despite a large volume of hydrological research. I suggest it is time to introduce more hydrology into flood estimation. The reliability of the current methods can be unsatisfactory. For example, despite the UK's relatively straightforward hydrology, regression estimates of the index flood are uncertain by +/- a factor of two (for a 95% confidence interval), an impractically large uncertainty for design. The standard error of rainfall-runoff model estimates is not usually known, but available assessments indicate poorer reliability than statistical methods. There is a practical need for improved reliability in flood estimation. Two promising candidates to supersede the existing methods are (i) continuous simulation by rainfall-runoff modelling and (ii) event-based derived distribution methods. The main challenge with continuous simulation methods in ungauged basins is to specify the model structure and parameter values, when calibration data are not available. This has been an active area of research for more than a decade, and this activity is likely to continue. The major challenges for the derived distribution method in ungauged catchments include not only the correct specification of model structure and parameter values, but also antecedent conditions (e.g. seasonal soil water balance). However, a much smaller community of researchers are active in developing or applying the derived distribution approach, and as a result slower progress is being made. A change in needed: surely we have learned enough about hydrology in the last 40 years that we can make a practical hydrological advance on our methods for flood estimation! A shift to new methods for flood estimation will not be taken lightly by practitioners. However, the standard for change is clear - can we develop new methods which give significant improvements in reliability over those existing methods which are demonstrably unsatisfactory?
Protocol - realist and meta-narrative evidence synthesis: Evolving Standards (RAMESES)
2011-01-01
Background There is growing interest in theory-driven, qualitative and mixed-method approaches to systematic review as an alternative to (or to extend and supplement) conventional Cochrane-style reviews. These approaches offer the potential to expand the knowledge base in policy-relevant areas - for example by explaining the success, failure or mixed fortunes of complex interventions. However, the quality of such reviews can be difficult to assess. This study aims to produce methodological guidance, publication standards and training resources for those seeking to use the realist and/or meta-narrative approach to systematic review. Methods/design We will: [a] collate and summarise existing literature on the principles of good practice in realist and meta-narrative systematic review; [b] consider the extent to which these principles have been followed by published and in-progress reviews, thereby identifying how rigour may be lost and how existing methods could be improved; [c] using an online Delphi method with an interdisciplinary panel of experts from academia and policy, produce a draft set of methodological steps and publication standards; [d] produce training materials with learning outcomes linked to these steps; [e] pilot these standards and training materials prospectively on real reviews-in-progress, capturing methodological and other challenges as they arise; [f] synthesise expert input, evidence review and real-time problem analysis into more definitive guidance and standards; [g] disseminate outputs to audiences in academia and policy. The outputs of the study will be threefold: 1. Quality standards and methodological guidance for realist and meta-narrative reviews for use by researchers, research sponsors, students and supervisors 2. A 'RAMESES' (Realist and Meta-review Evidence Synthesis: Evolving Standards) statement (comparable to CONSORT or PRISMA) of publication standards for such reviews, published in an open-access academic journal. 3. A training module for researchers, including learning outcomes, outline course materials and assessment criteria. Discussion Realist and meta-narrative review are relatively new approaches to systematic review whose overall place in the secondary research toolkit is not yet fully established. As with all secondary research methods, guidance on quality assurance and uniform reporting is an important step towards improving quality and consistency of studies. PMID:21843376
29 CFR 1910.95 - Occupational noise exposure.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Regulations Relating to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR OCCUPATIONAL SAFETY AND HEALTH STANDARDS Occupational Health and Environmental Control § 1910.95 Occupational... three methods developed by the National Institute for Occupational Safety and Health (NIOSH), which are...
Methods for Linking Item Parameters.
1981-08-01
within and across data sets; all proportion-correct distributions were quite platykurtic . Biserial item-total correlations had relatively consistent...would produce a distribution of a parameters which had a larger mean and standard deviation, was more positively skewed, and was somewhat more platykurtic
Hassan, Wafaa El-Sayed
2008-08-01
Three rapid, simple, reproducible and sensitive extractive colorimetric methods (A--C) for assaying dothiepin hydrochloride (I) and risperidone (II) in bulk sample and in dosage forms were investigated. Methods A and B are based on the formation of an ion pair complexes with methyl orange (A) and orange G (B), whereas method C depends on ternary complex formation between cobalt thiocyanate and the studied drug I or II. The optimum reaction conditions were investigated and it was observed the calibration curves resulting from the measurements of absorbance concentration relations of the extracted complexes were linear over the concentration range 0.1--12 microg ml(-1) for method A, 0.5--11 mug ml(-1) for method B, and 3.2--80 microg ml(-1) for method C with a relative standard deviation (RSD) of 1.17 and 1.28 for drug I and II, respectively. The molar absorptivity, Sandell sensitivity, Ringbom optimum concentration ranges, and detection and quantification limits for all complexes were calculated and evaluated at maximum wavelengths of 423, 498, and 625 nm, using methods A, B, and C, respectively. The interference from excipients commonly present in dosage forms and common degradation products was studied. The proposed methods are highly specific for the determination of drugs I and II, in their dosage forms applying the standard additions technique without any interference from common excipients. The proposed methods have been compared statistically to the reference methods and found to be simple, accurate (t-test) and reproducible (F-value).
The Standard Model in the history of the Natural Sciences, Econometrics, and the social sciences
NASA Astrophysics Data System (ADS)
Fisher, W. P., Jr.
2010-07-01
In the late 18th and early 19th centuries, scientists appropriated Newton's laws of motion as a model for the conduct of any other field of investigation that would purport to be a science. This early form of a Standard Model eventually informed the basis of analogies for the mathematical expression of phenomena previously studied qualitatively, such as cohesion, affinity, heat, light, electricity, and magnetism. James Clerk Maxwell is known for his repeated use of a formalized version of this method of analogy in lectures, teaching, and the design of experiments. Economists transferring skills learned in physics made use of the Standard Model, especially after Maxwell demonstrated the value of conceiving it in abstract mathematics instead of as a concrete and literal mechanical analogy. Haavelmo's probability approach in econometrics and R. Fisher's Statistical Methods for Research Workers brought a statistical approach to bear on the Standard Model, quietly reversing the perspective of economics and the social sciences relative to that of physics. Where physicists, and Maxwell in particular, intuited scientific method as imposing stringent demands on the quality and interrelations of data, instruments, and theory in the name of inferential and comparative stability, statistical models and methods disconnected theory from data by removing the instrument as an essential component. New possibilities for reconnecting economics and the social sciences to Maxwell's sense of the method of analogy are found in Rasch's probabilistic models for measurement.
Food increases the bioavailability of isotretinoin.
Colburn, W A; Gibson, D M; Wiens, R E; Hanigan, J J
1983-01-01
Twenty healthy male subjects received 80 mg (2 X 40 mg SEG capsules) oral isotretinoin separated by two-week washout periods in an open randomized crossover design. Isotretinoin was administered during a complete fast, 1 hour after a standard breakfast, with a standard breakfast, or 1 hour before a standard breakfast. Blood samples were obtained at specific times over a 72-hour period. Isotretinoin blood concentrations were determined by a specific HPLC method. The relative bioavailability (AUC) of isotretinoin was found to be approximately 1.5 to 2 times greater when the dose was administered 1 hour before, concomitantly with, or 1 hour after a meal than when it was given during a complete fast. In addition, because the Cmax value is lower when the dose is administered with food rather than 1 hour after a meal, coadministration of isotretinoin with food may be the best method of administration.
Expert system verification and validation study. Delivery 3A and 3B: Trip summaries
NASA Technical Reports Server (NTRS)
French, Scott
1991-01-01
Key results are documented from attending the 4th workshop on verification, validation, and testing. The most interesting part of the workshop was when representatives from the U.S., Japan, and Europe presented surveys of VV&T within their respective regions. Another interesting part focused on current efforts to define industry standards for artificial intelligence and how that might affect approaches to VV&T of expert systems. The next part of the workshop focused on VV&T methods of applying mathematical techniques to verification of rule bases and techniques for capturing information relating to the process of developing software. The final part focused on software tools. A summary is also presented of the EPRI conference on 'Methodologies, Tools, and Standards for Cost Effective Reliable Software Verification and Validation. The conference was divided into discussion sessions on the following issues: development process, automated tools, software reliability, methods, standards, and cost/benefit considerations.
NASA Technical Reports Server (NTRS)
Marley, Mike
2008-01-01
The focus of this paper will be on the thermal balance testing for the Operationally Responsive Space Standard Bus Battery. The Standard Bus thermal design required that the battery be isolated from the bus itself. This required the battery to have its own thermal control, including heaters and a radiator surface. Since the battery was not ready for testing during the overall bus thermal balance testing, a separate test was conducted to verify the thermal design for the battery. This paper will discuss in detail, the test set up, test procedure, and results from this test. Additionally this paper will consider the methods taken to determine the heat dissipation of the battery during charge and discharge. It seems that the heat dissipation for Lithium Ion batteries is relatively unknown and hard to quantify. The methods used during test and the post test analysis to estimate the heat dissipation of the battery will be discussed.
Xie, Wei-Qi; Gong, Yi-Xian; Yu, Kong-Xian
2017-08-18
This work investigates a new reaction headspace gas chromatographic (HS-GC) technique for efficient quantifying average valence of manganese (Mn) in manganese oxides. This method is on the basis of the oxidation reaction between manganese oxides and sodium oxalate under the acidic condition. The carbon dioxide (CO 2 ) formed from the oxidation reaction can be quantitatively analyzed by headspace gas chromatography. The data showed that the reaction in the closed headspace vial can be completed in 20min at 80°C. The relative standard deviation of this reaction HS-GC method in the precision testing was within 1.08%, the relative differences between the new method and the reference method (titration method) were no more than 5.71%. The new HS-GC method is automated, efficient, and can be a reliable tool for the quantitative analysis of average valence of manganese in the manganese oxide related research and applications. Copyright © 2017 Elsevier B.V. All rights reserved.
Stukel, Thérèse A.; Fisher, Elliott S; Wennberg, David E.; Alter, David A.; Gottlieb, Daniel J.; Vermeulen, Marian J.
2007-01-01
Context Comparisons of outcomes between patients treated and untreated in observational studies may be biased due to differences in patient prognosis between groups, often because of unobserved treatment selection biases. Objective To compare 4 analytic methods for removing the effects of selection bias in observational studies: multivariable model risk adjustment, propensity score risk adjustment, propensity-based matching, and instrumental variable analysis. Design, Setting, and Patients A national cohort of 122 124 patients who were elderly (aged 65–84 years), receiving Medicare, and hospitalized with acute myocardial infarction (AMI) in 1994–1995, and who were eligible for cardiac catheterization. Baseline chart reviews were taken from the Cooperative Cardiovascular Project and linked to Medicare health administrative data to provide a rich set of prognostic variables. Patients were followed up for 7 years through December 31, 2001, to assess the association between long-term survival and cardiac catheterization within 30 days of hospital admission. Main Outcome Measure Risk-adjusted relative mortality rate using each of the analytic methods. Results Patients who received cardiac catheterization (n=73 238) were younger and had lower AMI severity than those who did not. After adjustment for prognostic factors by using standard statistical risk-adjustment methods, cardiac catheterization was associated with a 50% relative decrease in mortality (for multivariable model risk adjustment: adjusted relative risk [RR], 0.51; 95% confidence interval [CI], 0.50–0.52; for propensity score risk adjustment: adjusted RR, 0.54; 95% CI, 0.53–0.55; and for propensity-based matching: adjusted RR, 0.54; 95% CI, 0.52–0.56). Using regional catheterization rate as an instrument, instrumental variable analysis showed a 16% relative decrease in mortality (adjusted RR, 0.84; 95% CI, 0.79–0.90). The survival benefits of routine invasive care from randomized clinical trials are between 8% and 21 %. Conclusions Estimates of the observational association of cardiac catheterization with long-term AMI mortality are highly sensitive to analytic method. All standard risk-adjustment methods have the same limitations regarding removal of unmeasured treatment selection biases. Compared with standard modeling, instrumental variable analysis may produce less biased estimates of treatment effects, but is more suited to answering policy questions than specific clinical questions. PMID:17227979
Zimmerman, L.R.; Hostetler, K.A.; Thurman, E.M.
2000-01-01
Analytical methods using high-performance liquid chromatography-diode array detection (HPLC-DAD) and high-performance liquid chromatography/mass spectrometry (HPLC/MS) were developed for the analysis of the following chloroacetanilide herbicide metabolites in water: acetochlor ethanesulfonic acid (ESA), acetochlor oxanilic acid (OXA), alachlor ESA, alachlor OXA, metolachlor ESA, and metolachlor OXA. Good precision and accuracy were demonstrated for both the HPLC-DAD and HPLC/MS methods in reagent water, surface water, and ground water. The mean HPLC-DAD recoveries of the chloroacetanilide herbicide metabolites from water samples spiked at 0.25, 0.50, and 2.0 mg/L (micrograms per liter) ranged from 84 to 112 percent, with relative standard deviations of 18 percent or less. The mean HPLC/MS recoveries of the metabolites from water samples spiked at 0.05, 0.20, and 2.0 mg/L ranged from 81 to 125 percent, with relative standard deviations of 20 percent or less. The limit of quantitation (LOQ) for all metabolites using the HPLC-DAD method was 0.20 mg/L, whereas the LOQ using the HPLC/MS method was 0.05 mg/L. These metabolite-determination methods are valuable for acquiring information about water quality and the fate and transport of the parent chloroacetanilide herbicides in water.
Wu, Qingqing; Xiang, Shengnan; Wang, Wenjun; Zhao, Jinyan; Xia, Jinhua; Zhen, Yueran; Liu, Bang
2018-05-01
Various detection methods have been developed to date for identification of animal species. New techniques based on PCR approach have raised the hope of developing better identification methods, which can overcome the limitations of the existing methods. PCR-based methods used the mitochondrial DNA (mtDNA) as well as nuclear DNA sequences. In this study, by targeting nuclear DNA, multiplex PCR and real-time PCR methods were developed to assist with qualitative and quantitative analysis. The multiplex PCR was found to simultaneously and effectively distinguish four species (fox, dog, mink, and rabbit) ingredients by the different sizes of electrophoretic bands: 480, 317, 220, and 209 bp. Real-time fluorescent PCR's amplification profiles and standard curves showed good quantitative measurement responses and linearity, as indicated by good repeatability and coefficient of determination R 2 > 0.99. The quantitative results of quaternary DNA mixtures including mink, fox, dog, and rabbit DNA are in line with our expectations: R.D. (relative deviation) varied between 1.98 and 12.23% and R.S.D. (relative standard deviation) varied between 3.06 and 11.51%, both of which are well within the acceptance criterion of ≤ 25%. Combining the two methods is suitable for the rapid identification and accurate quantification of fox-, dog-, mink-, and rabbit-derived ingredients in the animal products.
Delanghe, Joris R; Cobbaert, Christa; Galteau, Marie-Madeleine; Harmoinen, Aimo; Jansen, Rob; Kruse, Rolf; Laitinen, Päivi; Thienpont, Linda M; Wuyts, Birgitte; Weykamp, Cas; Panteghini, Mauro
2008-01-01
The European In Vitro Diagnostics (IVD) directive requires traceability to reference methods and materials of analytes. It is a task of the profession to verify the trueness of results and IVD compatibility. The results of a trueness verification study by the European Communities Confederation of Clinical Chemistry (EC4) working group on creatinine standardization are described, in which 189 European laboratories analyzed serum creatinine in a commutable serum-based material, using analytical systems from seven companies. Values were targeted using isotope dilution gas chromatography/mass spectrometry. Results were tested on their compliance to a set of three criteria: trueness, i.e., no significant bias relative to the target value, between-laboratory variation and within-laboratory variation relative to the maximum allowable error. For the lower and intermediate level, values differed significantly from the target value in the Jaffe and the dry chemistry methods. At the high level, dry chemistry yielded higher results. Between-laboratory coefficients of variation ranged from 4.37% to 8.74%. Total error budget was mainly consumed by the bias. Non-compensated Jaffe methods largely exceeded the total error budget. Best results were obtained for the enzymatic method. The dry chemistry method consumed a large part of its error budget due to calibration bias. Despite the European IVD directive and the growing needs for creatinine standardization, an unacceptable inter-laboratory variation was observed, which was mainly due to calibration differences. The calibration variation has major clinical consequences, in particular in pediatrics, where reference ranges for serum and plasma creatinine are low, and in the estimation of glomerular filtration rate.
Methodology for Evaluating Cost-effectiveness of Commercial Energy Code Changes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hart, Philip R.; Liu, Bing
This document lays out the U.S. Department of Energy’s (DOE’s) method for evaluating the cost-effectiveness of energy code proposals and editions. The evaluation is applied to provisions or editions of the American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE) Standard 90.1 and the International Energy Conservation Code (IECC). The method follows standard life-cycle cost (LCC) economic analysis procedures. Cost-effectiveness evaluation requires three steps: 1) evaluating the energy and energy cost savings of code changes, 2) evaluating the incremental and replacement costs related to the changes, and 3) determining the cost-effectiveness of energy code changes based on those costs andmore » savings over time.« less
[Determination of twenty one elements in lithium hexafluorophosphate by ICP-AES].
Fang, Yi-wen; Hao, Zhi-feng; Song, Yi-bing; Sun, Chang-yong; Yu, Jian; Yu, Lin
2005-02-01
One gram (+/- 0.0001 g) of lithium hexafluorophosphate was weighed exactly under dry atmosphere and was dissolved with an adequate amount of dimethyl carbonate (DMC). After the sample solution was pretreated with a series of methods, Be, Cu, Pb, Ca, Zr, Co, Mg, V, Ti, Mo, Ni, Mn, Sr, Zn, K, Al, Ba, Cd, Fe, Cr and Na were determined by ICP-AES. The results show that the recoveries of standard addition were 93.3%-102.1%, and the relative standard deviations (n = 11) were 0%-3.56%. The method is efficient, accurate and easy to operate. It has been applied to the determination of lithium hexafluorophosphate products with satisfactory results.
Temperature calibration of cryoscopic solutions used in the milk industry by adiabatic calorimetry
NASA Astrophysics Data System (ADS)
Méndez-Lango, E.; Lira-Cortes, L.; Quiñones-Ibarra, R.
2013-09-01
One method to detect extraneous water in milk is through cryoscopy. This method is used to measure the freezing point of milk. For calibration of a cryoscope there are is a set of standardized solution with known freezing points values. These values are related with the solute concentration, based in almost a century old data; it was no found recent results. It was found that reference solution are not certified in temperature: they do not have traceability to the temperature unit or standards. We prepared four solutions and measured them on a cryoscope and on an adiabatic calorimeter. It was found that results obtained with one technique dose not coincide with the other one.
NASA Astrophysics Data System (ADS)
Leif, Robert C.; Spidlen, Josef; Brinkman, Ryan R.
2008-02-01
Introduction: The International Society for Analytical Cytology, ISAC, is developing a new combined flow and image Analytical Cytometry Standard (ACS). This standard needs to serve both the research and clinical communities. The clinical medicine and clinical research communities have a need to exchange information with hospital and other clinical information systems. Methods: 1) Prototype the standard by creating CytometryML and a RAW format for binary data. 2) Join the ISAC Data Standards Task Force. 3) Create essential project documentation. 4) Cooperate with other groups by assisting in the preparation of the DICOM Supplement 122: Specimen Module and Pathology Service-Object Pair Classes. Results: CytometryML has been created and serves as a prototype and source of experience for the following: the Analytical Cytometry Standard (ACS) 1.0, the ACS container, Minimum Information about a Flow Cytometry Experiment (MIFlowCyt), and Requirements for a Data File Standard Format to Describe Flow Cytometry and Related Analytical Cytology Data. These requirements provide a means to judge the appropriateness of design elements and to develop tests for the final ACS. The requirements include providing the information required for understanding and reproducing a cytometry experiment or clinical measurement, and for a single standard for both flow and digital microscopic cytometry. Schemas proposed by other members of the ISAC Data Standards Task Force (e.g, Gating-ML) have been independently validated and have been integrated with CytometryML. The use of netCDF as an element of the ACS container has been proposed by others and a suggested method of its use is proposed.
Xie, Wei-Qi; Gong, Yi-Xian; Yu, Kong-Xian
2017-10-20
This work investigates an automated technique for rapid detecting the glucose content in glucose injection by reaction headspace gas chromatography (HS-GC). This method is based on the oxidation reaction of glucose in glucose injection with potassium dichromate. The carbon dioxide (CO 2 ) formed from the oxidation reaction can be quantitatively detected by GC. The results show that the relative standard deviation (RSD) of the present method was within 2.91%, and the measured glucose contents in glucose injection closely match those quantified by the reference method (relative differences <6.45%). The new HS-GC technique is rapid, practical and can be used to the batch detection of the glucose content in glucose injection related applications. Copyright © 2017 Elsevier B.V. All rights reserved.
Viera, Mariela S; Rizzetti, Tiele M; de Souza, Maiara P; Martins, Manoel L; Prestes, Osmar D; Adaime, Martha B; Zanella, Renato
2017-12-01
In this study, a QuEChERS (Quick, Easy, Cheap, Effective, Rugged and Safe) method, optimized by a 2 3 full factorial design, was developed for the determination of 72 pesticides in plant parts of carrot, corn, melon, rice, soy, silage, tobacco, cassava, lettuce and wheat by ultra-high-performance liquid chromatographic tandem mass spectrometry (UHPLC-MS/MS). Considering the complexity of these matrices and the need of use calibration in matrix, a new calibration approach based on single level standard addition in the sample (SLSAS) was proposed in this work and compared with the matrix-matched calibration (MMC), the procedural standard calibration (PSC) and the diluted standard addition calibration (DSAC). All approaches presented satisfactory validation parameters with recoveries from 70 to 120% and relative standard deviations≤20%. SLSAS was the most practical from the evaluated approaches and proved to be an effective way of calibration. Method limit of detection were between 4.8 and 48μgkg -1 and limit of quantification were from 16 to 160μgkg -1 . Method application to different kinds of plants found residues of 20 pesticides that were quantified with z-scores values≤2 in comparison with other calibration approaches. The proposed QuEChERS method combined with UHPLC-MS/MS analysis and using an easy and effective calibration procedure presented satisfactory results for pesticide residues determination in different crop plants and is a good alternative for routine analysis. Copyright © 2017 Elsevier B.V. All rights reserved.
Efficient global biopolymer sampling with end-transfer configurational bias Monte Carlo
NASA Astrophysics Data System (ADS)
Arya, Gaurav; Schlick, Tamar
2007-01-01
We develop an "end-transfer configurational bias Monte Carlo" method for efficient thermodynamic sampling of complex biopolymers and assess its performance on a mesoscale model of chromatin (oligonucleosome) at different salt conditions compared to other Monte Carlo moves. Our method extends traditional configurational bias by deleting a repeating motif (monomer) from one end of the biopolymer and regrowing it at the opposite end using the standard Rosenbluth scheme. The method's sampling efficiency compared to local moves, pivot rotations, and standard configurational bias is assessed by parameters relating to translational, rotational, and internal degrees of freedom of the oligonucleosome. Our results show that the end-transfer method is superior in sampling every degree of freedom of the oligonucleosomes over other methods at high salt concentrations (weak electrostatics) but worse than the pivot rotations in terms of sampling internal and rotational sampling at low-to-moderate salt concentrations (strong electrostatics). Under all conditions investigated, however, the end-transfer method is several orders of magnitude more efficient than the standard configurational bias approach. This is because the characteristic sampling time of the innermost oligonucleosome motif scales quadratically with the length of the oligonucleosomes for the end-transfer method while it scales exponentially for the traditional configurational-bias method. Thus, the method we propose can significantly improve performance for global biomolecular applications, especially in condensed systems with weak nonbonded interactions and may be combined with local enhancements to improve local sampling.
Reef Fish Survey Techniques: Assessing the Potential for Standardizing Methodologies.
Caldwell, Zachary R; Zgliczynski, Brian J; Williams, Gareth J; Sandin, Stuart A
2016-01-01
Dramatic changes in populations of fishes living on coral reefs have been documented globally and, in response, the research community has initiated efforts to assess and monitor reef fish assemblages. A variety of visual census techniques are employed, however results are often incomparable due to differential methodological performance. Although comparability of data may promote improved assessment of fish populations, and thus management of often critically important nearshore fisheries, to date no standardized and agreed-upon survey method has emerged. This study describes the use of methods across the research community and identifies potential drivers of method selection. An online survey was distributed to researchers from academic, governmental, and non-governmental organizations internationally. Although many methods were identified, 89% of survey-based projects employed one of three methods-belt transect, stationary point count, and some variation of the timed swim method. The selection of survey method was independent of the research design (i.e., assessment goal) and region of study, but was related to the researcher's home institution. While some researchers expressed willingness to modify their current survey protocols to more standardized protocols (76%), their willingness decreased when methodologies were tied to long-term datasets spanning five or more years. Willingness to modify current methodologies was also less common among academic researchers than resource managers. By understanding both the current application of methods and the reported motivations for method selection, we hope to focus discussions towards increasing the comparability of quantitative reef fish survey data.
Suendermann, Oliver; Ehlers, Anke; Boellinghaus, Inga; Gamer, Matthias; Glucksman, Edward
2010-01-01
BACKGROUND Trauma survivors with posttraumatic stress disorder (PTSD) report heightened physiological responses to a wide range of stimuli. It has been suggested that associative learning and stimulus generalization play a key role in the development of these symptoms. Some studies have found that trauma survivors with PTSD show greater physiological responses to individualized trauma reminders in the initial weeks after trauma than those without PTSD. This study investigated whether heart rate and skin conductance responses (HRR, SCR) to standardized trauma-related pictures at 1 month after the trauma predict chronic PTSD. METHOD Survivors of motor vehicle accidents or physical assaults (N=166) watched standardized trauma-related, generally threatening and neutral pictures at 1 month post- trauma while their HRR and SCR were recorded. PTSD symptoms were assessed with structured clinical interviews at 1 and 6 months; self-reports of fear responses and dissociation during trauma were obtained soon after the trauma. RESULTS At 1 month, trauma survivors with PTSD showed greater HRR to trauma-related pictures than those without PTSD, but not to general threat or neutral pictures. HRR to trauma-related pictures predicted PTSD severity at 1 and 6 months, and were related to fear and dissociation during trauma. SCR was not related to PTSD. CONCLUSION HRR to standardized trauma reminders at 1 month after the trauma differentiate between trauma survivors with and without PTSD, and predict chronic PTSD. Results are consistent with a role of associative learning in PTSD and suggest that early stimulus generalization may be an indicator of risk for chronic PTSD. PMID:20124426
Survey of Sterile Admixture Practices in Canadian Hospital Pharmacies: Part 1. Methods and Results
Warner, Travis; Nishi, Cesilia; Checkowski, Ryan; Hall, Kevin W.
2009-01-01
Background: The 1996 Guidelines for Preparation of Sterile Products in Pharmacies of the Canadian Society of Hospital Pharmacists (CSHP) represent the current standard of practice for sterile compounding in Canada. However, these guidelines are practice recommendations, not enforceable standards. Previous surveys of sterile compounding practices have shown that actual practice deviates markedly from voluntary practice recommendations. In 2004, the United States Pharmacopeia (USP) published its “General Chapter <797> Pharmaceutical Compounding—Sterile Preparations”, which set a more rigorous and enforceable standard for sterile compounding in the United States. Objectives: To assess sterile compounding practices in Canadian hospital pharmacies and to compare them with current CSHP recommendations and USP chapter <797> standards. Methods: An online survey, based on previous studies of sterile compounding practices, the CSHP guidelines, and the chapter <797> standards, was created and distributed to 193 Canadian hospital pharmacies. Results: A total of 133 pharmacies completed at least part of the survey, for a response rate of 68.9%. All respondents reported the preparation of sterile products. Various degrees of deviation from the practice recommendations were noted for virtually all areas of the CSHP guidelines and the USP standards. Low levels of compliance were most notable in the areas of facilities and equipment, process validation, and product testing. Availability in the central pharmacy of a clean room facility meeting or exceeding the criteria of International Organization for Standardization (ISO) class 8 is a requirement of the chapter <797> standards, but more than 40% of responding pharmacies reported that they did not have such a facility. Higher levels of compliance were noted for policies and procedures, garbing requirements, aseptic technique, and handling of hazardous products. Part 1 of this series reports the survey methods and results relating to policies, personnel, raw materials, storage and handling, facilities and equipment, and garments. Part 2 will report results relating to preparation of aseptic products, expiry dating, labelling, process validation, product testing and release, documentation, records, and disposal of hazardous pharmaceuticals. It will also highlight some of the key areas where there is considerable opportunity for improvement. Conclusion: This survey identified numerous deficiences in sterile compounding practices in Canadian hospital pharmacies. Awareness of these deficiencies may create an impetus for critical assessment and improvements in practice. PMID:22478875
USDA-ARS?s Scientific Manuscript database
We developed a sensitive mass spectrometry-based method of quantitating the prions present in elk and sheep. Calibration curves relating the area ratios of the selected analyte peptides and their homologous stable isotope labeled internal standards were prepared. This method was compared to the ELIS...
Raees Ahmad, Sufiyan Ahmad; Patil, Lalit; Mohammed Usman, Mohammed Rageeb; Imran, Mohammad; Akhtar, Rashid
2018-01-01
A simple rapid, accurate, precise, and reproducible validated reverse phase high performance liquid chromatography (HPLC) method was developed for the determination of Abacavir (ABAC) and Lamivudine (LAMI) in bulk and tablet dosage forms. The quantification was carried out using Symmetry Premsil C18 (250 mm × 4.6 mm, 5 μm) column run in isocratic way using mobile phase comprising methanol: water (0.05% orthophosphoric acid with pH 3) 83:17 v/v and a detection wavelength of 245 nm and injection volume of 20 μl, with a flow rate of 1 ml/min. In the developed method, the retention times of ABAC and LAMI were found to be 3.5 min and 7.4 min, respectively. The method was validated in terms of linearity, precision, accuracy, limits of detection, limits of quantitation, and robustness in accordance with the International Conference on Harmonization guidelines. The assay of the proposed method was found to be 99% - 101%. The recovery studies were also carried out and mean % recovery was found to be 99% - 101%. The % relative standard deviation from reproducibility was found to be <2%. The proposed method was statistically evaluated and can be applied for routine quality control analysis of ABAC and LAMI in bulk and in tablet dosage form. Attempts were made to develop RP-HPLC method for simultaneous estimation of Abacavir and Lamivudine for the RP-HPLC method. The developed method was validated according to the ICH guidelines. The linearity, precision, range, robustness were within the limits as specified by the ICH guidelines. Hence the method was found to be simple, accurate, precise, economic and reproducible. So the proposed methods can be used for the routine quality control analysis of Abacavir and Lamivudine in bulk drug as well as in formulations. Abbreviations Used: HPLC: High-performance liquid chromatography, UV: Ultraviolet, ICH: International Conference on Harmonization, ABAC: Abacavir, LAMI: Lamivudine, HIV: Human immunodeficiency virus, AIDS: Acquired immunodeficiency syndrome, NRTI: Nucleoside reverse transcriptase inhibitors, ARV: Antiretroviral, RSD: Relative standard deviation, RT: Retention time, SD: Standard deviation.
NASA Astrophysics Data System (ADS)
Canagaratna, M. R.; Jimenez, J. L.; Kroll, J. H.; Chen, Q.; Kessler, S. H.; Massoli, P.; Hildebrandt Ruiz, L.; Fortner, E.; Williams, L. R.; Wilson, K. R.; Surratt, J. D.; Donahue, N. M.; Jayne, J. T.; Worsnop, D. R.
2015-01-01
Elemental compositions of organic aerosol (OA) particles provide useful constraints on OA sources, chemical evolution, and effects. The Aerodyne high-resolution time-of-flight aerosol mass spectrometer (HR-ToF-AMS) is widely used to measure OA elemental composition. This study evaluates AMS measurements of atomic oxygen-to-carbon (O : C), hydrogen-to-carbon (H : C), and organic mass-to-organic carbon (OM : OC) ratios, and of carbon oxidation state (OS C) for a vastly expanded laboratory data set of multifunctional oxidized OA standards. For the expanded standard data set, the method introduced by Aiken et al. (2008), which uses experimentally measured ion intensities at all ions to determine elemental ratios (referred to here as "Aiken-Explicit"), reproduces known O : C and H : C ratio values within 20% (average absolute value of relative errors) and 12%, respectively. The more commonly used method, which uses empirically estimated H2O+ and CO+ ion intensities to avoid gas phase air interferences at these ions (referred to here as "Aiken-Ambient"), reproduces O : C and H : C of multifunctional oxidized species within 28 and 14% of known values. The values from the latter method are systematically biased low, however, with larger biases observed for alcohols and simple diacids. A detailed examination of the H2O+, CO+, and CO2+ fragments in the high-resolution mass spectra of the standard compounds indicates that the Aiken-Ambient method underestimates the CO+ and especially H2O+ produced from many oxidized species. Combined AMS-vacuum ultraviolet (VUV) ionization measurements indicate that these ions are produced by dehydration and decarboxylation on the AMS vaporizer (usually operated at 600 °C). Thermal decomposition is observed to be efficient at vaporizer temperatures down to 200 °C. These results are used together to develop an "Improved-Ambient" elemental analysis method for AMS spectra measured in air. The Improved-Ambient method uses specific ion fragments as markers to correct for molecular functionality-dependent systematic biases and reproduces known O : C (H : C) ratios of individual oxidized standards within 28% (13%) of the known molecular values. The error in Improved-Ambient O : C (H : C) values is smaller for theoretical standard mixtures of the oxidized organic standards, which are more representative of the complex mix of species present in ambient OA. For ambient OA, the Improved-Ambient method produces O : C (H : C) values that are 27% (11%) larger than previously published Aiken-Ambient values; a corresponding increase of 9% is observed for OM : OC values. These results imply that ambient OA has a higher relative oxygen content than previously estimated. The OS C values calculated for ambient OA by the two methods agree well, however (average relative difference of 0.06 OS C units). This indicates that OS C is a more robust metric of oxidation than O : C, likely since OS C is not affected by hydration or dehydration, either in the atmosphere or during analysis.
Auvert, J-F; Chleir, F; Coppé, G; Hamel-Desnos, C; Moraglia, L; Pichot, O
2014-02-01
The quality standards of the French Society for Vascular Medicine for the ultrasound assessment of the superficial venous system of the lower limbs are based on the two following requirements: technical know-how (mastering the use of ultrasound devices and the method of examination); medical know-how (ability to adapt the methods and scope of the examination to its clinical indications and purpose and to rationally analyze and interpret its results). To describe an optimal method of examination in relation to the clinical question and hypothesis; to achieve consistent practice, methods, glossary terminologies and reporting; to provide good practice reference points and to promote a high quality process. The three levels of examination. Their clinical indications and goals. The reference standard examination (level 2) and its variants according to clinical needs. The minimal content of the examination report, the letter to the referring physician (synthesis, conclusion and management suggestions) and iconography. Commented glossary (anatomy, hemodynamics, semiology). Technical basis. Ultrasound devices settings. We discuss of use of Duplex ultrasound for the assessment of the superficial veins of the lower limbs in vascular medicine practice. Copyright © 2014. Published by Elsevier Masson SAS.
Roberts, D J; Spellman, R A; Sanok, K; Chen, H; Chan, M; Yurt, P; Thakur, A K; DeVito, G L; Murli, H; Stankowski, L F
2012-05-01
A flow cytometric procedure for determining mitotic index (MI) as part of the metaphase chromosome aberrations assay, developed and utilized routinely at Pfizer as part of their standard assay design, has been adopted successfully by Covance laboratories. This method, using antibodies against phosphorylated histone tails (H3PS10) and nucleic acid stain, has been evaluated by the two independent test sites and compared to manual scoring. Primary human lymphocytes were treated with cyclophosphamide, mitomycin C, benzo(a)pyrene, and etoposide at concentrations inducing dose-dependent cytotoxicity. Deming regression analysis indicates that the results generated via flow cytometry (FCM) were more consistent between sites than those generated via microscopy. Further analysis using the Bland-Altman modification of the Tukey mean difference method supports this finding, as the standard deviations (SDs) of differences in MI generated by FCM were less than half of those generated manually. Decreases in scoring variability owing to the objective nature of FCM, and the greater number of cells analyzed, make FCM a superior method for MI determination. In addition, the FCM method has proven to be transferable and easily integrated into standard genetic toxicology laboratory operations. Copyright © 2012 Wiley Periodicals, Inc.
Canagaratna, M. R.; Jimenez, J. L.; Kroll, J. H.; ...
2014-07-31
Elemental compositions of organic aerosol (OA) particles provide useful constraints on OA sources, chemical evolution, and effects. The Aerodyne high-resolution time-of-flight aerosol mass spectrometer (HR-ToF-AMS) is widely used to measure OA elemental composition. This study evaluates AMS measurements of atomic oxygen-to-carbon (O : C), hydrogen-to-carbon (H : C), organic mass-to-organic carbon (OM : OC), and carbon oxidation state (OS C) for a vastly expanded laboratory dataset of multifunctional oxidized OA standards. For the expanded standard dataset, the "Aiken-Explicit" method (Aiken et al., 2008), which uses experimentally measured ion intensities at all ions to determine elemental ratios, reproduces known molecular Omore » : C and H : C ratio values within 20% (average absolute value of relative errors) and 12% respectively. The more commonly used "Aiken-Ambient" method, which uses empirically estimated H 2O + and CO + ion intensities to avoid gas phase air interferences at these ions, reproduces O : C and H : C of multifunctional oxidized species within 28% and 14% of known values. These values are systematically biased low, however, with larger biases observed for alcohols and simple diacids. A detailed examination of the H 2O +, CO +, and CO 2 + fragments in the high-resolution mass spectra of the standard compounds indicates that the Aiken-Ambient method underestimates the CO + and H 2O + produced from many oxidized species. Combined AMS-vacuum ultraviolet (VUV) ionization measurements indicate that these ions are produced by dehydration and decarboxylation on the AMS vaporizer (usually operated at 600 °C). Thermal decomposition is observed to be efficient at vaporizer temperatures down to 200 °C. These results are used together to develop an "Improved-Ambient" elemental analysis method for AMS spectra measured in air. The Improved-Ambient method reduces the systematic biases and reproduces O : C (H : C) ratios of individual oxidized standards within 28% (13%) of the known molecular values. The error in Improved-Ambient O : C and H : C values is smaller (12% and 4% respectively) for synthetic mixtures of the oxidized organic standards, which are more representative of the complex mix of species present in ambient OA. For ambient OA, the Improved-Ambient method produces O : C (H : C) values that are 27% (11%) larger than previously published Aiken-Ambient values; a corresponding increase of 9% is observed for OM : OC values. These results imply that ambient OA has a higher relative oxygen content than previously estimated. The OS C values calculated for ambient OA by the two methods agree well, however (average relative difference of 0.06 OS C units). This indicates that OS C is a more robust metric of oxidation than O : C, likely since OS C is not affected by hydration or dehydration, either in the atmosphere or during analysis.« less
Havlicek, Martin; Jan, Jiri; Brazdil, Milan; Calhoun, Vince D.
2015-01-01
Increasing interest in understanding dynamic interactions of brain neural networks leads to formulation of sophisticated connectivity analysis methods. Recent studies have applied Granger causality based on standard multivariate autoregressive (MAR) modeling to assess the brain connectivity. Nevertheless, one important flaw of this commonly proposed method is that it requires the analyzed time series to be stationary, whereas such assumption is mostly violated due to the weakly nonstationary nature of functional magnetic resonance imaging (fMRI) time series. Therefore, we propose an approach to dynamic Granger causality in the frequency domain for evaluating functional network connectivity in fMRI data. The effectiveness and robustness of the dynamic approach was significantly improved by combining a forward and backward Kalman filter that improved estimates compared to the standard time-invariant MAR modeling. In our method, the functional networks were first detected by independent component analysis (ICA), a computational method for separating a multivariate signal into maximally independent components. Then the measure of Granger causality was evaluated using generalized partial directed coherence that is suitable for bivariate as well as multivariate data. Moreover, this metric provides identification of causal relation in frequency domain, which allows one to distinguish the frequency components related to the experimental paradigm. The procedure of evaluating Granger causality via dynamic MAR was demonstrated on simulated time series as well as on two sets of group fMRI data collected during an auditory sensorimotor (SM) or auditory oddball discrimination (AOD) tasks. Finally, a comparison with the results obtained from a standard time-invariant MAR model was provided. PMID:20561919
Barik, Mayadhar; Bajpai, Minu; Patnaik, Santosh; Mishra, Pravash; Behera, Priyamadhaba; Dwivedi, Sada Nanda
2016-01-01
Background: Cryopreservation is basically related to meritorious thin samples or small clumps of cells that are cooled quickly without loss. Our main objective is to establish and formulate an innovative method and protocol development for cryopreservation as a gold standard for clinical uses in laboratory practice and treatment. The knowledge regarding usefulness of cryopreservation in clinical practice is essential to carry forward the clinical practice and research. Materials and Methods: We are trying to compare different methods of cryopreservation (in two dozen of cells) at the same time we compare the embryo and oocyte freezing interms of fertilization rate according to the International standard protocol. Results: The combination of cryoprotectants and regimes of rapid cooling and rinsing during warming often allows successful cryopreservation of biological materials, particularly cell suspensions or thin tissue samples. Examples include semen, blood, tissue samples like tumors, histological cross-sections, human eggs and human embryos. Although presently many studies have reported that the children born from frozen embryos or “frosties,” show consistently positive results with no increase in birth defects or development abnormalities is quite good enough and similar to our study (50–85%). Conclusions: We ensure that cryopreservation technology provided useful cell survivability, tissue and organ preservation in a proper way. Although it varies according to different laboratory conditions, it is certainly beneficial for patient's treatment and research. Further studies are needed for standardization and development of new protocol. PMID:27512686
Boué, Stéphanie; Exner, Thomas; Ghosh, Samik; Belcastro, Vincenzo; Dokler, Joh; Page, David; Boda, Akash; Bonjour, Filipe; Hardy, Barry; Vanscheeuwijck, Patrick; Hoeng, Julia; Peitsch, Manuel
2017-01-01
The US FDA defines modified risk tobacco products (MRTPs) as products that aim to reduce harm or the risk of tobacco-related disease associated with commercially marketed tobacco products. Establishing a product’s potential as an MRTP requires scientific substantiation including toxicity studies and measures of disease risk relative to those of cigarette smoking. Best practices encourage verification of the data from such studies through sharing and open standards. Building on the experience gained from the OpenTox project, a proof-of-concept database and website ( INTERVALS) has been developed to share results from both in vivo inhalation studies and in vitro studies conducted by Philip Morris International R&D to assess candidate MRTPs. As datasets are often generated by diverse methods and standards, they need to be traceable, curated, and the methods used well described so that knowledge can be gained using data science principles and tools. The data-management framework described here accounts for the latest standards of data sharing and research reproducibility. Curated data and methods descriptions have been prepared in ISA-Tab format and stored in a database accessible via a search portal on the INTERVALS website. The portal allows users to browse the data by study or mechanism (e.g., inflammation, oxidative stress) and obtain information relevant to study design, methods, and the most important results. Given the successful development of the initial infrastructure, the goal is to grow this initiative and establish a public repository for 21 st-century preclinical systems toxicology MRTP assessment data and results that supports open data principles. PMID:29123642
Shafaati, A; Clark, B J
2000-03-01
The development of a stability-indicating capillary zone electrophoresis (CZE) method for the determination of the drug azathioprine (AZA) and its related substances in bulk and dosage forms is described. Theophylline was used as an internal standard to improve quantitative results. The method was fully validated in terms of repeatability (n = 10, RSD for migration time and peak area ratio were 0.15% and 0.60%, respectively), reproducibility (n = 5, RSD of peak area ratio was 0.84%), linearity at two ranges of the azathioprine concentration, limits of detection (LOD) and quantitation (LOQ), and robustness. The method was applied for determination of the drug in bulk and a commercial tablet dosage form (recovery 98.3-101.3%) and in powder for injection (recovery 98.7-100.6%). The method was fast and reliable for the analysis of AZA and its related substances in bulk and dosage forms.
Li, Xiaobing; Shi, Fuguo; Gu, Pan; Liu, Lingye; He, Hua; Ding, Li
2014-04-01
A simple and sensitive HPLC-MS/MS method was developed and fully validated for the simultaneous determination of amygdalin (AD) and paeoniflorin (PF) in human plasma. For both analytes, the method exhibited high sensitivity (LLOQs of 0.6ng/mL) by selecting the ammonium adduct ions ([M+NH4](+)) as the precursor ions and good linearity over the concentration range of 0.6-2000ng/mL with the correlation coefficients>0.9972. The intra- and inter-day precision was lower than 10% in relation to relative standard deviation, while accuracy was within ±2.3% in terms of relative error for both analytes. The developed method was successfully applied to a pilot pharmacokinetic study of AD and PF in healthy volunteers after intravenous infusion administration of Huoxue-Tongluo lyophilized powder for injection. Copyright © 2014 Elsevier B.V. All rights reserved.
Combinatorics of transformations from standard to non-standard bases in Brauer algebras
NASA Astrophysics Data System (ADS)
Chilla, Vincenzo
2007-05-01
Transformation coefficients between standard bases for irreducible representations of the Brauer centralizer algebra \\mathfrak{B}_f(x) and split bases adapted to the \\mathfrak{B}_{f_1} (x) \\times \\mathfrak{B}_{f_2} (x) \\subset \\mathfrak{B}_f (x) subalgebra (f1 + f2 = f) are considered. After providing the suitable combinatorial background, based on the definition of the i-coupling relation on nodes of the subduction grid, we introduce a generalized version of the subduction graph which extends the one given in Chilla (2006 J. Phys. A: Math. Gen. 39 7657) for symmetric groups. Thus, we can describe the structure of the subduction system arising from the linear method and give an outline of the form of the solution space. An ordering relation on the grid is also given and then, as in the case of symmetric groups, the choices of the phases and of the free factors governing the multiplicity separations are discussed.
Determination of nutritional parameters of yoghurts by FT Raman spectroscopy
NASA Astrophysics Data System (ADS)
Czaja, Tomasz; Baranowska, Maria; Mazurek, Sylwester; Szostak, Roman
2018-05-01
FT-Raman quantitative analysis of nutritional parameters of yoghurts was performed with the help of partial least squares models. The relative standard errors of prediction for fat, lactose and protein determination in the quantified commercial samples equalled to 3.9, 3.2 and 3.6%, respectively. Models based on attenuated total reflectance spectra of the liquid yoghurt samples and of dried yoghurt films collected with the single reflection diamond accessory showed relative standard errors of prediction values of 1.6-5.0% and 2.7-5.2%, respectively, for the analysed components. Despite a relatively low signal-to-noise ratio in the obtained spectra, Raman spectroscopy, combined with chemometrics, constitutes a fast and powerful tool for macronutrients quantification in yoghurts. Errors received for attenuated total reflectance method were found to be relatively higher than those for Raman spectroscopy due to inhomogeneity of the analysed samples.
Takabatake, Reona; Masubuchi, Tomoko; Futo, Satoshi; Minegishi, Yasutaka; Noguchi, Akio; Kondo, Kazunari; Teshima, Reiko; Kurashima, Takeyo; Mano, Junichi; Kitta, Kazumi
2014-01-01
A novel real-time PCR-based analytical method was developed for the event-specific quantification of a genetically modified (GM) maize event, MIR162. We first prepared a standard plasmid for MIR162 quantification. The conversion factor (Cf) required to calculate the genetically modified organism (GMO) amount was empirically determined for two real-time PCR instruments, the Applied Biosystems 7900HT (ABI7900) and the Applied Biosystems 7500 (ABI7500) for which the determined Cf values were 0.697 and 0.635, respectively. To validate the developed method, a blind test was carried out in an interlaboratory study. The trueness and precision were evaluated as the bias and reproducibility of relative standard deviation (RSDr). The determined biases were less than 25% and the RSDr values were less than 20% at all evaluated concentrations. These results suggested that the limit of quantitation of the method was 0.5%, and that the developed method would thus be suitable for practical analyses for the detection and quantification of MIR162.
Multiplex cDNA quantification method that facilitates the standardization of gene expression data
Gotoh, Osamu; Murakami, Yasufumi; Suyama, Akira
2011-01-01
Microarray-based gene expression measurement is one of the major methods for transcriptome analysis. However, current microarray data are substantially affected by microarray platforms and RNA references because of the microarray method can provide merely the relative amounts of gene expression levels. Therefore, valid comparisons of the microarray data require standardized platforms, internal and/or external controls and complicated normalizations. These requirements impose limitations on the extensive comparison of gene expression data. Here, we report an effective approach to removing the unfavorable limitations by measuring the absolute amounts of gene expression levels on common DNA microarrays. We have developed a multiplex cDNA quantification method called GEP-DEAN (Gene expression profiling by DCN-encoding-based analysis). The method was validated by using chemically synthesized DNA strands of known quantities and cDNA samples prepared from mouse liver, demonstrating that the absolute amounts of cDNA strands were successfully measured with a sensitivity of 18 zmol in a highly multiplexed manner in 7 h. PMID:21415008
DOE Office of Scientific and Technical Information (OSTI.GOV)
Miller, D. C.; Gu, X.; Haldenman, S.
The curing of cross-linkable encapsulation is a critical consideration for photovoltaic (PV) modules manufactured using a lamination process. Concerns related to ethylene-co-vinyl acetate (EVA) include the quality (e.g., expiration and uniformity) of the films or completion (duration) of the cross-linking of the EVA within a laminator. Because these issues are important to both EVA and module manufacturers, an international standard has recently been proposed by the Encapsulation Task-Group within the Working Group 2 (WG2) of the International Electrotechnical Commission (IEC) Technical Committee 82 (TC82) for the quantification of the degree of cure for EVA encapsulation. The present draft of themore » standard calls for the use of differential scanning calorimetry (DSC) as the rapid, enabling secondary (test) method. Both the residual enthalpy- and melt/freeze-DSC methods are identified. The DSC methods are calibrated against the gel content test, the primary (reference) method. Aspects of other established methods, including indentation and rotor cure metering, were considered by the group. Key details of the test procedure will be described.« less
Variation in passing standards for graduation-level knowledge items at UK medical schools.
Taylor, Celia A; Gurnell, Mark; Melville, Colin R; Kluth, David C; Johnson, Neil; Wass, Val
2017-06-01
Given the absence of a common passing standard for students at UK medical schools, this paper compares independently set standards for common 'one from five' single-best-answer (multiple-choice) items used in graduation-level applied knowledge examinations and explores potential reasons for any differences. A repeated cross-sectional study was conducted. Participating schools were sent a common set of graduation-level items (55 in 2013-2014; 60 in 2014-2015). Items were selected against a blueprint and subjected to a quality review process. Each school employed its own standard-setting process for the common items. The primary outcome was the passing standard for the common items by each medical school set using the Angoff or Ebel methods. Of 31 invited medical schools, 22 participated in 2013-2014 (71%) and 30 (97%) in 2014-2015. Schools used a mean of 49 and 53 common items in 2013-2014 and 2014-2015, respectively, representing around one-third of the items in the examinations in which they were embedded. Data from 19 (61%) and 26 (84%) schools, respectively, met the inclusion criteria for comparison of standards. There were statistically significant differences in the passing standards set by schools in both years (effect sizes (f 2 ): 0.041 in 2013-2014 and 0.218 in 2014-2015; both p < 0.001). The interquartile range of standards was 5.7 percentage points in 2013-2014 and 6.5 percentage points in 2014-2015. There was a positive correlation between the relative standards set by schools in the 2 years (Pearson's r = 0.57, n = 18, p = 0.014). Time allowed per item, method of standard setting and timing of examination in the curriculum did not have a statistically significant impact on standards. Independently set standards for common single-best-answer items used in graduation-level examinations vary across UK medical schools. Further work to examine standard-setting processes in more detail is needed to help explain this variability and develop methods to reduce it. © 2017 John Wiley & Sons Ltd and The Association for the Study of Medical Education.
DETERMINATION OF AZOXYSTROBIN AND DIFENOCONAZOLE IN PESTICIDE PRODUCTS.
Lazić, S; Šunjka, D
2015-01-01
In this study a high performance liquid chromatographic (HPLC-DAD) procedure has been developed for the simultaneous determination of azoxystrobin and difenoconazole in suspension concentrate pesticide formulations, with the aim of the product quality control. Azoxystrobin, strobilurin fungicide and difenoconazole (cis,trans-3-chloro-4-[4-methyl-2-(1H-1,2,4-triazol-1-ylmethyl)-1,3-dioxolan-2-yl]phenyl 4-chlorophenyl ether), triazole fungicide, are used for the protection of plants from wide spectrum of fungal diseases. For the analysis LC system an Agilent Technologies 1100 Series was used. Good separation was achieved on a Zorbax SB-C18 column (5 μm, 250 mm x 3 mm internal diameter) using a mobile phase consisting of acetonitrile/ultrapure water (90:10, v/v), at a flow rate of 0.9 ml/minute and UV detection at 218 nm. Column temperature was 25 degrees C, injected volume was 1 μl. Retention times for azoxystrobin and difenoconazole were 2.504 min and 1.963 min, respectively. This method is validated according to the requirements for new methods, which include linearity, precision, accuracy and selectivity. The method demonstrates good linearity with r2 > 0.997. The repeatability of the method, expressed as relative standard deviation (RSD, %), was found to be 1.9% for azoxystrobin and 0.5% for difenoconazole. The precision of the method was also considered to be acceptable as the experimental repeatability relative standard deviation (RSD) was lower than the RSD calculated using the Horwitz equation of 1.7% and 1.4% for azoxystrobin and difenoconazole, respectively. The accuracy of the proposed method was determined from recovery experiments through standard addition procedure. The average recoveries of the three fortification levels were 101.9% for azoxystrobin and 103.2% for difenoconazole with RSDs of 1.1% and 1.2%. The method described in this paper is simple, precise, accurate and selective and represents a new and reliable way of simultaneous determination of azoxystrobin and difenoconazole in formulated products.
NASA Astrophysics Data System (ADS)
Cao, Qian; Wan, Xiaoxia; Li, Junfeng; Liu, Qiang; Liang, Jingxing; Li, Chan
2016-10-01
This paper proposed two weight functions based on principal component analysis (PCA) to reserve more colorimetric information in spectral data compression process. One weight function consisted of the CIE XYZ color-matching functions representing the characteristic of the human visual system, while another was made up of the CIE XYZ color-matching functions of human visual system and relative spectral power distribution of the CIE standard illuminant D65. The improvement obtained from the proposed two methods were tested to compress and reconstruct the reflectance spectra of 1600 glossy Munsell color chips and 1950 Natural Color System color chips as well as six multispectral images. The performance was evaluated by the mean values of color difference under the CIE 1931 standard colorimetric observer and the CIE standard illuminant D65 and A. The mean values of root mean square errors between the original and reconstructed spectra were also calculated. The experimental results show that the proposed two methods significantly outperform the standard PCA and another two weighted PCA in the aspects of colorimetric reconstruction accuracy with very slight degradation in spectral reconstruction accuracy. In addition, weight functions with the CIE standard illuminant D65 can improve the colorimetric reconstruction accuracy compared to weight functions without the CIE standard illuminant D65.
Ninfali, Paolino; Gennari, Lorenzo; Biagiotti, Enrica; Cangi, Francesca; Mattoli, Luisa; Maidecchi, Anna
2009-01-01
Botanical extracts are standardized to > or = 1 marker compounds (MCs). This standardization provides a certain level of quality control, but not complete quality assurance. Thus, industries are looking for other satisfactory systems to improve standardization. This study focuses on the standardization of herbal medicines by combining 2 parameters: the concentration of the MC and antioxidant capacity. Antioxidant capacity was determined with the oxygen radical absorbance capacity (ORAC) method and the concentrations of the MCs, by high-performance liquid chromatography. Total phenols were also determined by the Folin-Ciocolteau method. The ORAC values, expressed as micromol Trolox equivalents/100 g (ORAC %), of 12 commercial herbal extracts were related to the ORAC values of the respective pure MCs at the concentrations at which the MCs occur in products (ORAC-MC %). The ORAC % values of 11 extracts were higher than those of the respective MCs and the ratios ORAC-MC %/ORAC % ranged from 0.007 to 0.7, whereas in the case of Olea europaea leaves, the same ratio was 1.36. The ORAC parameters and their ratios, as well as the linear relationship between ORAC-MC % and ORAC %, are described and discussed as tools for improving the standardization of herbal products and detecting modifications due to herb processing and storage.
ROOT BIOMASS ALLOCATION IN THE WORLD'S UPLAND FORESTS
Because the world's forests play a major role in regulating nutrient and carbon cycles, there is much interest in estimating their biomass. Estimates of aboveground biomass based on well-established methods are relatively abundant; estimates of root biomass based on standard meth...
Medical microscopic image matching based on relativity
NASA Astrophysics Data System (ADS)
Xie, Fengying; Zhu, Liangen; Jiang, Zhiguo
2003-12-01
In this paper, an effective medical micro-optical image matching algorithm based on relativity is described. The algorithm includes the following steps: Firstly, selecting a sub-area that has obvious character in one of the two images as standard image; Secondly, finding the right matching position in the other image; Thirdly, applying coordinate transformation to merge the two images together. As a kind of application of image matching in medical micro-optical image, this method overcomes the shortcoming of microscope whose visual field is little and makes it possible to watch a big object or many objects in one view. Simultaneously it implements adaptive selection of standard image, and has a satisfied matching speed and result.
Gao, Yuan; Zhang, Haijun; Zou, Lili; Wu, Ping; Yu, Zhengkun; Lu, Xianbo; Chen, Jiping
2016-04-05
Analysis of short-chain chlorinated paraffins (SCCPs) is extremely difficult because of their complex compositions with thousands of isomers and homologues. A novel analytical method, deuterodechlorination combined with high resolution gas chromatography-high resolution mass spectrometry (HRGC-HRMS), was developed. A protocol is applied in the deuterodechlorination of SCCPs with LiAlD4, and the formed deuterated n-alkanes of different alkane chains can be distinguished readily from each other on the basis of their retention time and fragment mass ([M](+)) by HRGC-HRMS. An internal standard quantification of individual SCCP congeners was achieved, in which branched C10-CPs and branched C12-CPs were used as the extraction and reaction internal standards, respectively. A maximum factor of 1.26 of the target SCCP concentrations were determined by this method, and the relative standard deviations for quantification of total SCCPs were within 10%. This method was applied to determine the congener compositions of SCCPs in commercial chlorinated paraffins and environmental and biota samples after method validation. Low-chlorinated SCCP congeners (Cl1-4) were found to account for 32.4%-62.4% of the total SCCPs. The present method provides an attractive perspective for further studies on the toxicological and environmental characteristics of SCCPs.
Jiang, Ting-Fu; Lv, Zhi-Hua; Wang, Yuan-Hong; Yue, Mei-E
2006-06-01
A new, simple and rapid capillary electrophoresis (CE) method, using hexadimethrine bromide (HDB) as electroosmotic flow (EOF) modifier, was developed for the identification and quantitative determination of four plant hormones, including gibberellin A3 (GA3), indole-3-acetic acid (IAA), alpha-naphthaleneacetic acid (NAA) and 4-chlorophenoxyacetic acid (4-CA). The optimum separation was achieved with 20 mM borate buffer at pH 10.00 containing 0.005% (w/v) of HDB. The applied voltage was -25 kV and the capillary temperature was kept constant at 25 degrees C. Salicylic acid was used as internal standard for quantification. The calibration dependencies exhibited good linearity within the ratios of the concentrations of standard samples and internal standard and the ratios of the peak areas of samples and internal standard. The correlation coefficients were from 0.9952 to 0.9997. The relative standard deviations of migration times and peak areas were < 1.93 and 6.84%, respectively. The effects of buffer pH, the concentration of HDB and the voltage on the resolution were studied systematically. By this method, the contents of plant hormone in biofertilizer were successfully determined within 7 min, with satisfactory repeatability and recovery.
Nirogi, Ramakrishna V S; Kandikere, Vishwottam N; Mudigonda, Koteshwara; Maurya, Santosh
2007-02-01
A simple, rapid, sensitive, and selective liquid chromatography-tandem mass spectrometry method is developed and validated for the quantitation of galantamine, an acetylcholinesterase inhibitor in human plasma, using a commercially available compound, loratadine, as the internal standard. Following liquid-liquid extraction, the analytes are separated using an isocratic mobile phase on a reverse-phase C18 column and analyzed by mass spectrometry in the multiple reaction monitoring mode using the respective (M+H)+ ions, m/z 288 to 213 for galantamine and m/z 383 and 337 for the internal standard. The assay exhibit a linear dynamic range of 0.5-100 ng/mL for galantamine in human plasma. The lower limit of quantitation is 0.5 ng/mL, with a relative standard deviation of less than 8%. Acceptable precision and accuracy are obtained for concentrations over the standard curve range. A run time of 2.5 min for each sample makes it possible to analyze more than 400 human plasma samples per day. The validated method is successfully used to analyze human plasma samples for application in pharmacokinetic, bioavailability, or bioequivalence studies.
Vavalle, Nicholas A; Jelen, Benjamin C; Moreno, Daniel P; Stitzel, Joel D; Gayzik, F Scott
2013-01-01
Objective evaluation methods of time history signals are used to quantify how well simulated human body responses match experimental data. As the use of simulations grows in the field of biomechanics, there is a need to establish standard approaches for comparisons. There are 2 aims of this study. The first is to apply 3 objective evaluation methods found in the literature to a set of data from a human body finite element model. The second is to compare the results of each method, examining how they are correlated to each other and the relative strengths and weaknesses of the algorithms. In this study, the methods proposed by Sprague and Geers (magnitude and phase error, SGM and SGP), Rhule et al. (cumulative standard deviation, CSD), and Gehre et al. (CORrelation and Analysis, or CORA, size, phase, shape, corridor) were compared. A 40 kph frontal sled test presented by Shaw et al. was simulated using the Global Human Body Models Consortium midsized male full-body finite element model (v. 3.5). Mean and standard deviation experimental data (n = 5) from Shaw et al. were used as the benchmark. Simulated data were output from the model at the appropriate anatomical locations for kinematic comparison. Force data were output at the seat belts, seat pan, knee, and foot restraints. Objective comparisons from 53 time history data channels were compared to the experimental results. To compare the different methods, all objective comparison metrics were cross-plotted and linear regressions were calculated. The following ratings were found to be statistically significantly correlated (P < .01): SGM and CORrelation and Analysis (CORA) size, R (2) = 0.73; SGP and CORA shape, R (2) = 0.82; and CSD and CORA's corridor factor, R (2) = 0.59. Relative strengths of the correlated ratings were then investigated. For example, though correlated to CORA size, SGM carries a sign to indicate whether the simulated response is greater than or less than the benchmark signal. A further analysis of the advantages and drawbacks of each method is discussed. The results demonstrate that a single metric is insufficient to provide a complete assessment of how well the simulated results match the experiments. The CORA method provided the most comprehensive evaluation of the signal. Regardless of the method selected, one primary recommendation of this work is that for any comparison, the results should be reported to provide separate assessments of a signal's match to experimental variance, magnitude, phase, and shape. Future work planned includes implementing any forthcoming International Organization for Standardization standards for objective evaluations. Supplemental materials are available for this article. Go to the publisher's online edition of Traffic Injury Prevention to view the supplemental file.
Clark, Carl C.; Yudenfriend, Herbert; Redner, Alex S.
2000-01-01
Glazing types are historically described, with the laceration injuries and ejection deaths associated with present glazing. Sixty tempered glass windows manufactured at nominally four temper levels were tested for uncracked fracture fragment size and weight and length by the American and European standards, which fracture the glass without strain, and our preliminary strain fracture test, which produces longer uncracked fragments and heavier clusters of fragments. Our study relates the results by the three methods to the temper measurements using birefringence, with a discussion of alternate safer glazing and the inadequacy of present standards for reducing laceration and ejection dangers. PMID:11558078
Determination of Porosity in Shale by Double Headspace Extraction GC Analysis.
Zhang, Chun-Yun; Li, Teng-Fei; Chai, Xin-Sheng; Xiao, Xian-Ming; Barnes, Donald
2015-11-03
This paper reports on a novel method for the rapid determination of the shale porosity by double headspace extraction gas chromatography (DHE-GC). Ground core samples of shale were placed into headspace vials and DHE-GC measurements of released methane gas were performed at a given time interval. A linear correlation between shale porosity and the ratio of consecutive GC signals was established both theoretically and experimentally by comparing with the results from the standard helium pycnometry method. The results showed that (a) the porosity of ground core samples of shale can be measured within 30 min; (b) the new method is not significantly affected by particle size of the sample; (c) the uncertainties of measured porosities of nine shale samples by the present method range from 0.31 to 0.46 p.u.; and (d) the results obtained by the DHE-GC method are in a good agreement with those from the standard helium pycnometry method. In short, the new DHE-GC method is simple, rapid, and accurate, making it a valuable tool for shale gas-related research and applications.
2010-08-01
available). It is assumed after this method is formally published that various standard vendors will offer other sources than the current single standard... single isomer. D Alkyl PAHs used to determine the SPME-GC/MS relative response factors including alkyl naphthalenes (1-methyl-, 2-methyl-, 1,2...Flag all compound results in the sample which were estimated above the upper calibration level with an “E” qualifier. 15. Precision and Bias 15.1 Single
Evaluation of Acoustic Doppler Current Profiler measurements of river discharge
Morlock, S.E.
1996-01-01
The standard deviations of the ADCP measurements ranged from approximately 1 to 6 percent and were generally higher than the measurement errors predicted by error-propagation analysis of ADCP instrument performance. These error-prediction methods assume that the largest component of ADCP discharge measurement error is instrument related. The larger standard deviations indicate that substantial portions of measurement error may be attributable to sources unrelated to ADCP electronics or signal processing and are functions of the field environment.
NASA Astrophysics Data System (ADS)
Jin, Huang; Ling, Lin; Jun, Guo; Jianguo, Li; Yongzhong, Wang
2017-11-01
Facing the increasingly severe situation of air pollution, China are now positively promoting the evaluation of high efficiency air pollution control equipments and the research of the relative national standards. This paper showed the significance and the effect of formulating the technical requirements of high efficiency precipitator equipments for assessment national standards in power industries as well as the research thoughts and principle of these standards. It introduce the qualitative and quantitative evaluation requirements of high efficiency precipitators using in power industries and the core technical content such as testing, calculating, evaluation methods and so on. The implementation of a series of national standards is in order to lead and promote the production and application of high efficiency precipitator equipments in the field of the prevention of air pollution in national power industries.
Bringing Standardized Processes in Atom-Probe Tomography: I Establishing Standardized Terminology
DOE Office of Scientific and Technical Information (OSTI.GOV)
Anderson, Ian M; Danoix, F; Forbes, Richard
2011-01-01
Defining standardized methods requires careful consideration of the entire field and its applications. The International Field Emission Society (IFES) has elected a Standards Committee, whose task is to determine the needed steps to establish atom-probe tomography as an accepted metrology technique. Specific tasks include developing protocols or standards for: terminology and nomenclature; metrology and instrumentation, including specifications for reference materials; test methodologies; modeling and simulations; and science-based health, safety, and environmental practices. The Committee is currently working on defining terminology related to atom-probe tomography with the goal to include terms into a document published by the International Organization for Standardsmore » (ISO). A lot of terms also used in other disciplines have already been defined) and will be discussed for adoption in the context of atom-probe tomography.« less
Selvi, Emine Kılıçkaya; Şahin, Uğur; Şahan, Serkan
2017-01-01
This method was developed for the determination of trace amounts of aluminum(III) in dialysis concentrates using atomic absorption spectrometry after coprecipitation with lanthanum phosphate. The analytical parameters that influenced the quantitative coprecipitation of analyte including amount of lanthanum, amount of phosfate, pH and duration time were optimized. The % recoveries of the analyte ion were in the range of 95-105 % with limit of detection (3s) of 0.5 µg l -1 . Preconcentration factor was found as 1000 and Relative Standard Deviation (RSD) % value obtained from model solutions was 2.5% for 0.02 mg L -1 . The accuracy of the method was evaluated with standard reference material (CWW-TMD Waste Water). The method was also applied to most concentrated acidic and basic dialysis concentrates with satisfactory results.
Comparison of bursting pressure results of LPG tank using experimental and finite element method.
Aksoley, M Egemen; Ozcelik, Babur; Bican, Ismail
2008-03-01
In this study, the resistance of liquefied-petroleum gas (LPG) tanks produced from carbon steel sheet metal of different thicknesses has been investigated by bursting pressure experiments and non-linear Finite Element Method (FEM) method by increasing internal pressure values. The designs of LPG tanks produced from sheet metal to be used at the study have been realized by analytical calculations made taking into consideration of related standards. Bursting pressure tests have been performed that were inclined to decreasing the sheet thickness of LPG tanks used in industry. It has been shown that the LPG tanks can be produced in compliance with the standards when the sheet thickness is lowered from 3 to 2.8mm. The FEM results have displayed close values with the bursting results obtained from the experiments.
Wang, Yi-Ya; Zhan, Xiu-Chun
2014-04-01
Evaluating uncertainty of analytical results with 165 geological samples by polarized dispersive X-ray fluorescence spectrometry (P-EDXRF) has been reported according to the internationally accepted guidelines. One hundred sixty five pressed pellets of similar matrix geological samples with reliable values were analyzed by P-EDXRF. These samples were divided into several different concentration sections in the concentration ranges of every component. The relative uncertainties caused by precision and accuracy of 27 components were evaluated respectively. For one element in one concentration, the relative uncertainty caused by precision can be calculated according to the average value of relative standard deviation with different concentration level in one concentration section, n = 6 stands for the 6 results of one concentration level. The relative uncertainty caused by accuracy in one concentration section can be evaluated by the relative standard deviation of relative deviation with different concentration level in one concentration section. According to the error propagation theory, combining the precision uncertainty and the accuracy uncertainty into a global uncertainty, this global uncertainty acted as method uncertainty. This model of evaluating uncertainty can solve a series of difficult questions in the process of evaluating uncertainty, such as uncertainties caused by complex matrix of geological samples, calibration procedure, standard samples, unknown samples, matrix correction, overlap correction, sample preparation, instrument condition and mathematics model. The uncertainty of analytical results in this method can act as the uncertainty of the results of the similar matrix unknown sample in one concentration section. This evaluation model is a basic statistical method owning the practical application value, which can provide a strong base for the building of model of the following uncertainty evaluation function. However, this model used a lot of samples which cannot simply be applied to other types of samples with different matrix samples. The number of samples is too large to adapt to other type's samples. We will strive for using this study as a basis to establish a reasonable basis of mathematical statistics function mode to be applied to different types of samples.
A crowdsourcing workflow for extracting chemical-induced disease relations from free text
Li, Tong Shu; Bravo, Àlex; Furlong, Laura I.; Good, Benjamin M.; Su, Andrew I.
2016-01-01
Relations between chemicals and diseases are one of the most queried biomedical interactions. Although expert manual curation is the standard method for extracting these relations from the literature, it is expensive and impractical to apply to large numbers of documents, and therefore alternative methods are required. We describe here a crowdsourcing workflow for extracting chemical-induced disease relations from free text as part of the BioCreative V Chemical Disease Relation challenge. Five non-expert workers on the CrowdFlower platform were shown each potential chemical-induced disease relation highlighted in the original source text and asked to make binary judgments about whether the text supported the relation. Worker responses were aggregated through voting, and relations receiving four or more votes were predicted as true. On the official evaluation dataset of 500 PubMed abstracts, the crowd attained a 0.505 F-score (0.475 precision, 0.540 recall), with a maximum theoretical recall of 0.751 due to errors with named entity recognition. The total crowdsourcing cost was $1290.67 ($2.58 per abstract) and took a total of 7 h. A qualitative error analysis revealed that 46.66% of sampled errors were due to task limitations and gold standard errors, indicating that performance can still be improved. All code and results are publicly available at https://github.com/SuLab/crowd_cid_relex Database URL: https://github.com/SuLab/crowd_cid_relex PMID:27087308
Li, Ning; Du, Jian; Yang, Jing; Fan, Qiang; Tian, Wen
2017-11-01
A gas standard mixture containing 22 chlorinated hydrocarbons in high purity nitrogen was prepared using a two-step weighing method and a gasifying apparatus developed in-house. The concentration of each component was determined using a gas chromatograph with flame ionization detection (GC/FID). Linear regression analysis of every component was performed using the gas standard mixture with concentrations ranging from 1 to 10 μmol/mol, showing the complete gasification of volatile organic compound (VOCs) species in a selected cylinder. Repeatability was also examined to ensure the reliability of the preparation method. In addition, no significant difference was observed between domestic treated and imported treated cylinders, which were conducive to reduction of the cost of raw materials. Moreover, the results of stability testing at different pressures and long-term stability tests indicated that the gas standard at 1 μmol/mol level with relative expanded uncertainties of 5% was stable above 2 MPa for a minimum of 12 months. Finally, a quantity comparison was conducted between the gas standard and a commercial gas standard from Scott Specialty Gases (now Air Liquide America Specialty Gases). The excellent agreement of every species suggested the favorable accuracy of our gas standard. Therefore, this reference material can be applied to routine observation of VOCs and for other purposes.
Gibson, Richard; Becerril-Bravo, Elías; Silva-Castro, Vanessa; Jiménez, Blanca
2007-10-26
Although the trend in development of analytical methods for emerging contaminants is towards reduced sample preparation and increased detector selectivity, there are still benefits from removal of matrix material during sample preparation. This paper describes a simple method for acidic pharmaceuticals and a range of potential endocrine disrupting compounds in untreated wastewaters and spring waters. It is based on separation of the two classes during elution from the extraction cartridge with final analysis by gas chromatography-mass spectrometry. 3,4-D was used as the recovery standard for the acids while 4-n-nonylphenol and [2H4]estrone were used for the endocrine disrupters; mean recoveries varied between 89% and 111%. The method was also extensively validated by fortification with the target compounds. Recoveries of acids were from 68% to 97% with relative standard deviations generally less than 10% and recoveries of endocrine disrupters were 68-109% with relative standard deviations less than 20%. Detection limits varied from 0.005 to 1 ng/L in spring water, and from 0.5 to 100 ng/L in untreated wastewater. Concentrations of the analytes in the wastewater ranged from 0.018 to 22.4 microg/L. Values were comparable to reported data, although concentrations were generally relatively high, probably because of a lack of treatment. Triclosan, phthalates, estrone, 17beta-estradiol, ibuprofen, and naproxen were present in the spring water from aquifers recharged indirectly with this wastewater after its use for irrigation; concentrations ranged from 0.01 to 25.0 ng/L. The much lower concentrations compared to wastewater indicate effective removal processes on passage through the soil and subsoil.
NASA Astrophysics Data System (ADS)
Tsai, Suh-Jen Jane; Shiue, Chia-Chann; Chang, Shiow-Ing
1997-07-01
The analytical characteristics of copper in nickel-base alloys have been investigated with electrothermal atomic absorption spectrometry. Deuterium background correction was employed. The effects of various chemical modifiers on the analysis of copper were investigated. Organic modifiers which included 2-(5-bromo-2-pyridylazo)-5-(diethylamino-phenol) (Br-PADAP), ammonium citrate, 1-(2-pyridylazo)-naphthol, 4-(2-pyridylazo)resorcinol, ethylenediaminetetraacetic acid and Triton X-100 were studied. Inorganic modifiers palladium nitrate, magnesium nitrate, aluminum chloride, ammonium dihydrogen phosphate, hydrogen peroxide and potassium nitrate were also applied in this work. In addition, zirconium hydroxide and ammonium hydroxide precipitation methods have also been studied. Interference effects were effectively reduced with Br-PADAP modifier. Aqueous standards were used to construct the calibration curves. The detection limit was 1.9 pg. Standard reference materials of nickel-base alloys were used to evaluate the accuracy of the proposed method. The copper contents determined with the proposed method agreed closely with the certified values of the reference materials. The recoveries were within the range 90-100% with relative standard deviation of less than 10%. Good precision was obtained.
Taher, Mohammad Ali; Pourmohammad, Fatemeh; Fazelirad, Hamid
2015-12-01
In the present work, an electrothermal atomic absorption spectrometric method has been developed for the determination of ultra-trace amounts of rhodium after adsorption of its 2-(5-bromo-2-pyridylazo)-5-diethylaminophenol/tetraphenylborate ion associated complex at the surface of alumina. Several factors affecting the extraction efficiency such as the pH, type of eluent, sample and eluent flow rates, sorption capacity of alumina and sample volume were investigated and optimized. The relative standard deviation for eight measurements of 0.1 ng/mL of rhodium was ±6.3%. In this method, the detection limit was 0.003 ng/mL in the original solution. The sorption capacity of alumina and the linear range for Rh(III) were evaluated as 0.8 mg/g and 0.015-0.45 ng/mL in the original solution, respectively. The proposed method was successfully applied for the extraction and determination of rhodium content in some food and standard samples with high recovery values. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
NASA Astrophysics Data System (ADS)
Batzias, Dimitris F.; Karvounis, Sotirios
2012-12-01
Technology transfer may take place in parallel with cooperative action between companies participating in the same organizational scheme or using one another as subcontractor (outsourcing). In this case, cooperation should be realized by means of Standard Methods and Recommended Practices (SRPs) to achieve (i) quality of intermediate/final products according to specifications and (ii) industrial process control as required to guarantee such quality with minimum deviation (corresponding to maximum reliability) from preset mean values of representative quality parameters. This work deals with the design of the network of SRPs needed in each case for successful cooperation, implying also the corresponding technology transfer, effectuated through a methodological framework developed in the form of an algorithmic procedure with 20 activity stages and 8 decision nodes. The functionality of this methodology is proved by presenting the path leading from (and relating) a standard test method for toluene, as petrochemical feedstock in the toluene diisocyanate production, to the (6 generations distance upstream) performance evaluation of industrial process control systems (ie., from ASTM D5606 to BS EN 61003-1:2004 in the SRPs network).
Nested PCR Biases in Interpreting Microbial Community Structure in 16S rRNA Gene Sequence Datasets
Yu, Guoqin; Fadrosh, Doug; Goedert, James J.; Ravel, Jacques; Goldstein, Alisa M.
2015-01-01
Background Sequencing of the PCR-amplified 16S rRNA gene has become a common approach to microbial community investigations in the fields of human health and environmental sciences. This approach, however, is difficult when the amount of DNA is too low to be amplified by standard PCR. Nested PCR can be employed as it can amplify samples with DNA concentration several-fold lower than standard PCR. However, potential biases with nested PCRs that could affect measurement of community structure have received little attention. Results In this study, we used 17 DNAs extracted from vaginal swabs and 12 DNAs extracted from stool samples to study the influence of nested PCR amplification of the 16S rRNA gene on the estimation of microbial community structure using Illumina MiSeq sequencing. Nested and standard PCR methods were compared on alpha- and beta-diversity metrics and relative abundances of bacterial genera. The effects of number of cycles in the first round of PCR (10 vs. 20) and microbial diversity (relatively low in vagina vs. high in stool) were also investigated. Vaginal swab samples showed no significant difference in alpha diversity or community structure between nested PCR and standard PCR (one round of 40 cycles). Stool samples showed significant differences in alpha diversity (except Shannon’s index) and relative abundance of 13 genera between nested PCR with 20 cycles in the first round and standard PCR (P<0.01), but not between nested PCR with 10 cycles in the first round and standard PCR. Operational taxonomic units (OTUs) that had low relative abundance (sum of relative abundance <0.167) accounted for most of the distortion (>27% of total OTUs in stool). Conclusions Nested PCR introduced bias in estimated diversity and community structure. The bias was more significant for communities with relatively higher diversity and when more cycles were applied in the first round of PCR. We conclude that nested PCR could be used when standard PCR does not work. However, rare taxa detected by nested PCR should be validated by other technologies. PMID:26196512
Nested PCR Biases in Interpreting Microbial Community Structure in 16S rRNA Gene Sequence Datasets.
Yu, Guoqin; Fadrosh, Doug; Goedert, James J; Ravel, Jacques; Goldstein, Alisa M
2015-01-01
Sequencing of the PCR-amplified 16S rRNA gene has become a common approach to microbial community investigations in the fields of human health and environmental sciences. This approach, however, is difficult when the amount of DNA is too low to be amplified by standard PCR. Nested PCR can be employed as it can amplify samples with DNA concentration several-fold lower than standard PCR. However, potential biases with nested PCRs that could affect measurement of community structure have received little attention. In this study, we used 17 DNAs extracted from vaginal swabs and 12 DNAs extracted from stool samples to study the influence of nested PCR amplification of the 16S rRNA gene on the estimation of microbial community structure using Illumina MiSeq sequencing. Nested and standard PCR methods were compared on alpha- and beta-diversity metrics and relative abundances of bacterial genera. The effects of number of cycles in the first round of PCR (10 vs. 20) and microbial diversity (relatively low in vagina vs. high in stool) were also investigated. Vaginal swab samples showed no significant difference in alpha diversity or community structure between nested PCR and standard PCR (one round of 40 cycles). Stool samples showed significant differences in alpha diversity (except Shannon's index) and relative abundance of 13 genera between nested PCR with 20 cycles in the first round and standard PCR (P<0.01), but not between nested PCR with 10 cycles in the first round and standard PCR. Operational taxonomic units (OTUs) that had low relative abundance (sum of relative abundance <0.167) accounted for most of the distortion (>27% of total OTUs in stool). Nested PCR introduced bias in estimated diversity and community structure. The bias was more significant for communities with relatively higher diversity and when more cycles were applied in the first round of PCR. We conclude that nested PCR could be used when standard PCR does not work. However, rare taxa detected by nested PCR should be validated by other technologies.
Feldsine, Philip T; Leung, Stephanie C; Lienau, Andrew H; Mui, Linda A; Townsend, David E
2003-01-01
The relative efficacy of the SimPlate Total Plate Count-Color Indicator (TPC-CI) method (SimPlate 35 degrees C) was compared with the AOAC Official Method 966.23 (AOAC 35 degrees C) for enumeration of total aerobic microorganisms in foods. The SimPlate TPC-CI method, incubated at 30 degrees C (SimPlate 30 degrees C), was also compared with the International Organization for Standardization (ISO) 4833 method (ISO 30 degrees C). Six food types were analyzed: ground black pepper, flour, nut meats, frozen hamburger patties, frozen fruits, and fresh vegetables. All foods tested were naturally contaminated. Nineteen laboratories throughout North America and Europe participated in the study. Three method comparisons were conducted. In general, there was <0.3 mean log count difference in recovery among the SimPlate methods and their corresponding reference methods. Mean log counts between the 2 reference methods were also very similar. Repeatability (Sr) and reproducibility (SR) standard deviations were similar among the 3 method comparisons. The SimPlate method (35 degrees C) and the AOAC method were comparable for enumerating total aerobic microorganisms in foods. Similarly, the SimPlate method (30 degrees C) was comparable to the ISO method when samples were prepared and incubated according to the ISO method.
NASA Astrophysics Data System (ADS)
Baum, Lisa
There is gap in passing rates on the standardized science assessment between European American and Hispanic American students. The purpose of this study was to examine student performance in science and the closing of the achievement gap between European American and Hispanic American students based upon receipt of an inquiry or noninquiry instruction method. Guided by the theoretical framework of constructive learning, this quantitative ex post facto research design gathered data from 8 teachers who had already implemented 1 of the 2 methods of instruction. The teachers were chosen through purposive sampling based on previous observations of instructional method and were placed into 2 groups depending upon the type of instruction: inquiry or noninquiry. Descriptive statistics were used to determine mean differences and a 2-way analysis of variance was used to determine mean differences in science test scores between European American and Hispanic American students and between the instructional methods to which they had been exposed. Results found that the inquiry instructional method was related to a significant increase in mean scores for both ethnic groups, but the achievement gap between the two groups was not closed by the inquiry instruction method. This study can promote positive social change for students by informing the efforts of educational leaders and teachers to create professional development using inquiry instruction. Students may perform higher on standardized tests when they are allowed to explore science by asking questions and answering their own questions through the collection and analysis of data.
Hesselmann, Andreas; Görling, Andreas
2011-01-21
A recently introduced time-dependent exact-exchange (TDEXX) method, i.e., a response method based on time-dependent density-functional theory that treats the frequency-dependent exchange kernel exactly, is reformulated. In the reformulated version of the TDEXX method electronic excitation energies can be calculated by solving a linear generalized eigenvalue problem while in the original version of the TDEXX method a laborious frequency iteration is required in the calculation of each excitation energy. The lowest eigenvalues of the new TDEXX eigenvalue equation corresponding to the lowest excitation energies can be efficiently obtained by, e.g., a version of the Davidson algorithm appropriate for generalized eigenvalue problems. Alternatively, with the help of a series expansion of the new TDEXX eigenvalue equation, standard eigensolvers for large regular eigenvalue problems, e.g., the standard Davidson algorithm, can be used to efficiently calculate the lowest excitation energies. With the help of the series expansion as well, the relation between the TDEXX method and time-dependent Hartree-Fock is analyzed. Several ways to take into account correlation in addition to the exact treatment of exchange in the TDEXX method are discussed, e.g., a scaling of the Kohn-Sham eigenvalues, the inclusion of (semi)local approximate correlation potentials, or hybrids of the exact-exchange kernel with kernels within the adiabatic local density approximation. The lowest lying excitations of the molecules ethylene, acetaldehyde, and pyridine are considered as examples.
Mezouari, S; Liu, W Yun; Pace, G; Hartman, T G
2015-01-01
The objective of this study was to develop an improved analytical method for the determination of 3-chloro-1,2-propanediol (3-MCPD) and 1,3-dichloropropanol (1,3-DCP) in paper-type food packaging. The established method includes aqueous extraction, matrix spiking of a deuterated surrogate internal standard (3-MCPD-d₅), clean-up using Extrelut solid-phase extraction, derivatisation using a silylation reagent, and GC-MS analysis of the chloropropanols as their corresponding trimethyl silyl ethers. The new method is applicable to food-grade packaging samples using European Commission standard aqueous extraction and aqueous food stimulant migration tests. In this improved method, the derivatisation procedure was optimised; the cost and time of the analysis were reduced by using 10 times less sample, solvents and reagents than in previously described methods. Overall the validation data demonstrate that the method is precise and reliable. The limit of detection (LOD) of the aqueous extract was 0.010 mg kg(-1) (w/w) for both 3-MCPD and 1,3-DCP. Analytical precision had a relative standard deviation (RSD) of 3.36% for 3-MCPD and an RSD of 7.65% for 1,3-DCP. The new method was satisfactorily applied to the analysis of over 100 commercial paperboard packaging samples. The data are being used to guide the product development of a next generation of wet-strength resins with reduced chloropropanol content, and also for risk assessments to calculate the virtual safe dose (VSD).
Ozarda, Yesim; Ichihara, Kiyoshi; Aslan, Diler; Aybek, Hulya; Ari, Zeki; Taneli, Fatma; Coker, Canan; Akan, Pinar; Sisman, Ali Riza; Bahceci, Onur; Sezgin, Nurzen; Demir, Meltem; Yucel, Gultekin; Akbas, Halide; Ozdem, Sebahat; Polat, Gurbuz; Erbagci, Ayse Binnur; Orkmez, Mustafa; Mete, Nuriye; Evliyaoglu, Osman; Kiyici, Aysel; Vatansev, Husamettin; Ozturk, Bahadir; Yucel, Dogan; Kayaalp, Damla; Dogan, Kubra; Pinar, Asli; Gurbilek, Mehmet; Cetinkaya, Cigdem Damla; Akin, Okhan; Serdar, Muhittin; Kurt, Ismail; Erdinc, Selda; Kadicesme, Ozgur; Ilhan, Necip; Atali, Dilek Sadak; Bakan, Ebubekir; Polat, Harun; Noyan, Tevfik; Can, Murat; Bedir, Abdulkerim; Okuyucu, Ali; Deger, Orhan; Agac, Suret; Ademoglu, Evin; Kaya, Ayşem; Nogay, Turkan; Eren, Nezaket; Dirican, Melahat; Tuncer, GulOzlem; Aykus, Mehmet; Gunes, Yeliz; Ozmen, Sevda Unalli; Kawano, Reo; Tezcan, Sehavet; Demirpence, Ozlem; Degirmen, Elif
2014-12-01
A nationwide multicenter study was organized to establish reference intervals (RIs) in the Turkish population for 25 commonly tested biochemical analytes and to explore sources of variation in reference values, including regionality. Blood samples were collected nationwide in 28 laboratories from the seven regions (≥400 samples/region, 3066 in all). The sera were collectively analyzed in Uludag University in Bursa using Abbott reagents and analyzer. Reference materials were used for standardization of test results. After secondary exclusion using the latent abnormal values exclusion method, RIs were derived by a parametric method employing the modified Box-Cox formula and compared with the RIs by the non-parametric method. Three-level nested ANOVA was used to evaluate variations among sexes, ages and regions. Associations between test results and age, body mass index (BMI) and region were determined by multiple regression analysis (MRA). By ANOVA, differences of reference values among seven regions were significant in none of the 25 analytes. Significant sex-related and age-related differences were observed for 10 and seven analytes, respectively. MRA revealed BMI-related changes in results for uric acid, glucose, triglycerides, high-density lipoprotein (HDL)-cholesterol, alanine aminotransferase, and γ-glutamyltransferase. Their RIs were thus derived by applying stricter criteria excluding individuals with BMI >28 kg/m2. Ranges of RIs by non-parametric method were wider than those by parametric method especially for those analytes affected by BMI. With the lack of regional differences and the well-standardized status of test results, the RIs derived from this nationwide study can be used for the entire Turkish population.
NASA Astrophysics Data System (ADS)
Khabarova, K. Yu.; Kudeyarov, K. S.; Kolachevsky, N. N.
2017-06-01
Research and development in the field of optical clocks based on ultracold atoms and ions have enabled the relative uncertainty in frequency to be reduced down to a few parts in 1018. The use of novel, precise frequency comparison methods opens up new possibilities for basic research (sensitive tests of general relativity, a search for a drift of fundamental constants and a search for ‘dark matter’) as well as for state-of-the-art navigation and gravimetry. We discuss the key methods that are used in creating precision clocks (including transportable clocks) based on ultracold atoms and ions and the feasibility of using them in resolving current relativistic gravimetry issues.
Standard-less analysis of Zircaloy clad samples by an instrumental neutron activation method
NASA Astrophysics Data System (ADS)
Acharya, R.; Nair, A. G. C.; Reddy, A. V. R.; Goswami, A.
2004-03-01
A non-destructive method for analysis of irregular shape and size samples of Zircaloy has been developed using the recently standardized k0-based internal mono standard instrumental neutron activation analysis (INAA). The samples of Zircaloy-2 and -4 tubes, used as fuel cladding in Indian boiling water reactors (BWR) and pressurized heavy water reactors (PHWR), respectively, have been analyzed. Samples weighing in the range of a few tens of grams were irradiated in the thermal column of Apsara reactor to minimize neutron flux perturbations and high radiation dose. The method utilizes in situ relative detection efficiency using the γ-rays of selected activation products in the sample for overcoming γ-ray self-attenuation. Since the major and minor constituents (Zr, Sn, Fe, Cr and/or Ni) in these samples were amenable to NAA, the absolute concentrations of all the elements were determined using mass balance instead of using the concentration of the internal mono standard. Concentrations were also determined in a smaller size Zircaloy-4 sample by irradiating in the core position of the reactor to validate the present methodology. The results were compared with literature specifications and were found to be satisfactory. Values of sensitivities and detection limits have been evaluated for the elements analyzed.
Isaman, V; Thelin, R
1995-09-01
Standard Operating Procedures (SOPs) are required in order to comply with the Good Laboratory Practice Standards (GLPS) as promulgated in the Federal Insecticide, Fungicide and Rodenticide Act (FIFRA) 40 CFR Part 160. Paragraph 160.81 (a) states: "A testing facility shall have standard operating procedures in writing setting forth study methods that management is satisfied are adequate to insure the quality and integrity of the data generated in the course of a study." Types of SOPs include administrative and personnel, analyses, substances, quality assurance and records, test system, equipment, and field related. All SOPs must be adequate in scope to describe the function in sufficient detail such that the study data are reproducible. All SOPs must be approved by a management level as described in a corporate organization chart. Signatures for SOP responsibility, authorship, and Quality Assurance review adds strength and accountability to the SOP. In the event a procedure or method is performed differently from what is stated in the SOP, an SOP deviation is necessary. As methods and procedures are improved, SOP revisions are necessary to maintain SOP adequacy and applicability. The replaced SOP is put into a historical SOP file and all copies of the replaced SOPs are destroyed.
NASA Astrophysics Data System (ADS)
Hudoklin, D.; Šetina, J.; Drnovšek, J.
2012-09-01
The measurement of the water-vapor permeation rate (WVPR) through materials is very important in many industrial applications such as the development of new fabrics and construction materials, in the semiconductor industry, packaging, vacuum techniques, etc. The demand for this kind of measurement grows considerably and thus many different methods for measuring the WVPR are developed and standardized within numerous national and international standards. However, comparison of existing methods shows a low level of mutual agreement. The objective of this paper is to demonstrate the necessary uncertainty evaluation for WVPR measurements, so as to provide a basis for development of a corresponding reference measurement standard. This paper presents a specially developed measurement setup, which employs a precision dew-point sensor for WVPR measurements on specimens of different shapes. The paper also presents a physical model, which tries to account for both dynamic and quasi-static methods, the common types of WVPR measurements referred to in standards and scientific publications. An uncertainty evaluation carried out according to the ISO/IEC guide to the expression of uncertainty in measurement (GUM) shows the relative expanded ( k = 2) uncertainty to be 3.0 % for WVPR of 6.71 mg . h-1 (corresponding to permeance of 30.4 mg . m-2. day-1 . hPa-1).
NASA Technical Reports Server (NTRS)
Otterson, D. A.; Seng, G. T.
1984-01-01
A new high-performance liquid chromatographic (HPLC) method for group-type analysis of middistillate fuels is described. It uses a refractive index detector and standards that are prepared by reacting a portion of the fuel sample with sulfuric acid. A complete analysis of a middistillate fuel for saturates and aromatics (including the preparation of the standard) requires about 15 min if standards for several fuels are prepared simultaneously. From model fuel studies, the method was found to be accurate to within 0.4 vol% saturates or aromatics, and provides a precision of + or - 0.4 vol%. Olefin determinations require an additional 15 min of analysis time. However, this determination is needed only for those fuels displaying a significant olefin response at 200 nm (obtained routinely during the saturated/aromatics analysis procedure). The olefin determination uses the responses of the olefins and the corresponding saturates, as well as the average value of their refractive index sensitivity ratios (1.1). Studied indicated that, although the relative error in the olefins result could reach 10 percent by using this average sensitivity ratio, it was 5 percent for the fuels used in this study. Olefin concentrations as low as 0.1 vol% have been determined using this method.
Duff, Kevin
2012-01-01
Repeated assessments are a relatively common occurrence in clinical neuropsychology. The current paper will review some of the relevant concepts (e.g., reliability, practice effects, alternate forms) and methods (e.g., reliable change index, standardized based regression) that are used in repeated neuropsychological evaluations. The focus will be on the understanding and application of these concepts and methods in the evaluation of the individual patient through examples. Finally, some future directions for assessing change will be described. PMID:22382384
White, Helen E; Hedges, John; Bendit, Israel; Branford, Susan; Colomer, Dolors; Hochhaus, Andreas; Hughes, Timothy; Kamel-Reid, Suzanne; Kim, Dong-Wook; Modur, Vijay; Müller, Martin C; Pagnano, Katia B; Pane, Fabrizio; Radich, Jerry; Cross, Nicholas C P; Labourier, Emmanuel
2013-06-01
Current guidelines for managing Philadelphia-positive chronic myeloid leukemia include monitoring the expression of the BCR-ABL1 (breakpoint cluster region/c-abl oncogene 1, non-receptor tyrosine kinase) fusion gene by quantitative reverse-transcription PCR (RT-qPCR). Our goal was to establish and validate reference panels to mitigate the interlaboratory imprecision of quantitative BCR-ABL1 measurements and to facilitate global standardization on the international scale (IS). Four-level secondary reference panels were manufactured under controlled and validated processes with synthetic Armored RNA Quant molecules (Asuragen) calibrated to reference standards from the WHO and the NIST. Performance was evaluated in IS reference laboratories and with non-IS-standardized RT-qPCR methods. For most methods, percent ratios for BCR-ABL1 e13a2 and e14a2 relative to ABL1 or BCR were robust at 4 different levels and linear over 3 logarithms, from 10% to 0.01% on the IS. The intraassay and interassay imprecision was <2-fold overall. Performance was stable across 3 consecutive lots, in multiple laboratories, and over a period of 18 months to date. International field trials demonstrated the commutability of the reagents and their accurate alignment to the IS within the intra- and interlaboratory imprecision of IS-standardized methods. The synthetic calibrator panels are robust, reproducibly manufactured, analytically calibrated to the WHO primary standards, and compatible with most BCR-ABL1 RT-qPCR assay designs. The broad availability of secondary reference reagents will further facilitate interlaboratory comparative studies and independent quality assessment programs, which are of paramount importance for worldwide standardization of BCR-ABL1 monitoring results and the optimization of current and new therapeutic approaches for chronic myeloid leukemia. © 2013 American Association for Clinical Chemistry.
Torabizadeh, Mahsa; Talebpour, Zahra; Adib, Nuoshin; Aboul-Enein, Hassan Y
2016-04-01
A new monolithic coating based on vinylpyrrolidone-ethylene glycol dimethacrylate polymer was introduced for stir bar sorptive extraction. The polymerization step was performed using different contents of monomer, cross-linker and porogenic solvent, and the best formulation was selected. The quality of the prepared vinylpyrrolidone-ethylene glycol dimethacrylate stir bars was satisfactory, demonstrating good repeatability within batch (relative standard deviation < 3.5%) and acceptable reproducibility between batches (relative standard deviation < 6.0%). The prepared stir bar was utilized in combination with ultrasound-assisted liquid desorption, followed by high-performance liquid chromatography with ultraviolet detection for the simultaneous determination of diazepam and nordazepam in human plasma samples. To optimize the extraction step, a three-level, four-factor, three-block Box-Behnken design was applied. Under the optimum conditions, the analytical performance of the proposed method displayed excellent linear dynamic ranges for diazepam (36-1200 ng/mL) and nordazepam (25-1200 ng/mL), with correlation coefficients of 0.9986 and 0.9968 and detection limits of 12 and 10 ng/mL, respectively. The intra- and interday recovery ranged from 93 to 106%, and the relative standard deviations were less than 6%. Finally, the proposed method was successfully applied to the analysis of diazepam and nordazepam at their therapeutic levels in human plasma. The novelty of this study is the improved polarity of the stir bar coating and its application for the simultaneous extraction of diazepam and its active metabolite, nordazepam in human plasma sample. The method was more rapid than previously reported stir bar sorptive extraction techniques based on monolithic coatings, and exhibited lower detection limits in comparison with similar methods for the determination of diazepam and nordazepam in biological fluids. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
2010-01-01
Background Cluster analysis, and in particular hierarchical clustering, is widely used to extract information from gene expression data. The aim is to discover new classes, or sub-classes, of either individuals or genes. Performing a cluster analysis commonly involve decisions on how to; handle missing values, standardize the data and select genes. In addition, pre-processing, involving various types of filtration and normalization procedures, can have an effect on the ability to discover biologically relevant classes. Here we consider cluster analysis in a broad sense and perform a comprehensive evaluation that covers several aspects of cluster analyses, including normalization. Result We evaluated 2780 cluster analysis methods on seven publicly available 2-channel microarray data sets with common reference designs. Each cluster analysis method differed in data normalization (5 normalizations were considered), missing value imputation (2), standardization of data (2), gene selection (19) or clustering method (11). The cluster analyses are evaluated using known classes, such as cancer types, and the adjusted Rand index. The performances of the different analyses vary between the data sets and it is difficult to give general recommendations. However, normalization, gene selection and clustering method are all variables that have a significant impact on the performance. In particular, gene selection is important and it is generally necessary to include a relatively large number of genes in order to get good performance. Selecting genes with high standard deviation or using principal component analysis are shown to be the preferred gene selection methods. Hierarchical clustering using Ward's method, k-means clustering and Mclust are the clustering methods considered in this paper that achieves the highest adjusted Rand. Normalization can have a significant positive impact on the ability to cluster individuals, and there are indications that background correction is preferable, in particular if the gene selection is successful. However, this is an area that needs to be studied further in order to draw any general conclusions. Conclusions The choice of cluster analysis, and in particular gene selection, has a large impact on the ability to cluster individuals correctly based on expression profiles. Normalization has a positive effect, but the relative performance of different normalizations is an area that needs more research. In summary, although clustering, gene selection and normalization are considered standard methods in bioinformatics, our comprehensive analysis shows that selecting the right methods, and the right combinations of methods, is far from trivial and that much is still unexplored in what is considered to be the most basic analysis of genomic data. PMID:20937082
Yan, Yongqiu; Lu, Yu; Jiang, Shiping; Jiang, Yu; Tong, Yingpeng; Zuo, Limin; Yang, Jun; Gong, Feng; Zhang, Ling; Wang, Ping
2018-01-01
Background: Noni juice has been extensively used as folk medicine for the treatment of arthritis, infections, analgesic, colds, cancers, and diabetes by Polynesians for many years. Due to the lack of standard scientific evaluation methods, various kinds of commercial Noni juice with different quality and price were available on the market. Objective: To establish a sensitive, reliable, and accurate high-performance liquid chromatography with electrospray ionization triple quadrupole mass spectrometry (HPLC-ESI-MS/MS) method for separation, identification, and simultaneous quantitative analysis of bioactive constituents in Noni juice. Materials and Methods: The analytes and eight batches of commercially available samples from different origins were separated and analyzed by the HPLC-ESI-MS/MS method on an Agilent ZORBAX SB-C18 (150 mm × 4.6 mm i.d., 5 μm) column using a gradient elution of acetonitrile-methanol-0.05% glacial acetic acid in water (v/v) at a constant flow rate of 0.5 mL/min. Results: Seven components were identification and all of the assay parameters were within the required limits. Components were within the correlation coefficient values (R2 ≥ 0.9993) at the concentration ranges tested. The precision of the assay method was <0.91% and the repeatability between 1.36% and 3.31%. The accuracy varied from 96.40% to 103.02% and the relative standard deviations of stability were <3.91%. Samples from the same origin showed similar content while different origins showed significant different result. Conclusions: The developed methods would provide a reliable basis and be useful in the establishment of a rational quality control standard of Noni juice. SUMMARY Separation, identification, and simultaneous quantitative analysis method of seven bioactive constituents in Noni juice is originally developed by high-performance liquid chromatography with electrospray ionization triple quadrupole mass spectrometryThe presented method was successfully applied to the quality control of eight batches of commercially available samples of Noni juiceThis method is simple, sensitive, reliable, accurate, and efficient method with strong specificity, good precision, and high recovery rate and provides a reliable basis for quality control of Noni juice. Abbreviations used: HPLC-ESI-MS/MS: High-performance liquid chromatography with electrospray ionization triple quadrupole mass spectrometry, LOD: Limit of detection, LOQ: Limit of quantitation, S/N: Signal-to-noise ratio, RSD: Relative standard deviations, DP: Declustering potential, CE: Collision energy, MRM: Multiple reaction monitoring, RT: Retention time. PMID:29576704
Geographic Gossip: Efficient Averaging for Sensor Networks
NASA Astrophysics Data System (ADS)
Dimakis, Alexandros D. G.; Sarwate, Anand D.; Wainwright, Martin J.
Gossip algorithms for distributed computation are attractive due to their simplicity, distributed nature, and robustness in noisy and uncertain environments. However, using standard gossip algorithms can lead to a significant waste in energy by repeatedly recirculating redundant information. For realistic sensor network model topologies like grids and random geometric graphs, the inefficiency of gossip schemes is related to the slow mixing times of random walks on the communication graph. We propose and analyze an alternative gossiping scheme that exploits geographic information. By utilizing geographic routing combined with a simple resampling method, we demonstrate substantial gains over previously proposed gossip protocols. For regular graphs such as the ring or grid, our algorithm improves standard gossip by factors of $n$ and $\\sqrt{n}$ respectively. For the more challenging case of random geometric graphs, our algorithm computes the true average to accuracy $\\epsilon$ using $O(\\frac{n^{1.5}}{\\sqrt{\\log n}} \\log \\epsilon^{-1})$ radio transmissions, which yields a $\\sqrt{\\frac{n}{\\log n}}$ factor improvement over standard gossip algorithms. We illustrate these theoretical results with experimental comparisons between our algorithm and standard methods as applied to various classes of random fields.
Kim, Jae-Hwan; Park, Saet-Byul; Roh, Hyo-Jeong; Shin, Min-Ki; Moon, Gui-Im; Hong, Jin-Hwan; Kim, Hae-Yeong
2017-07-01
One novel standard reference plasmid, namely pUC-RICE5, was constructed as a positive control and calibrator for event-specific qualitative and quantitative detection of genetically modified (GM) rice (Bt63, Kemingdao1, Kefeng6, Kefeng8, and LLRice62). pUC-RICE5 contained fragments of a rice-specific endogenous reference gene (sucrose phosphate synthase) as well as the five GM rice events. An existing qualitative PCR assay approach was modified using pUC-RICE5 to create a quantitative method with limits of detection correlating to approximately 1-10 copies of rice haploid genomes. In this quantitative PCR assay, the square regression coefficients ranged from 0.993 to 1.000. The standard deviation and relative standard deviation values for repeatability ranged from 0.02 to 0.22 and 0.10% to 0.67%, respectively. The Ministry of Food and Drug Safety (Korea) validated the method and the results suggest it could be used routinely to identify five GM rice events. Copyright © 2017 Elsevier Ltd. All rights reserved.
Ye, Hongping; Hill, John; Kauffman, John; Han, Xianlin
2010-05-01
The capability of iTRAQ (isotope tags for relative and absolute quantification) reagents coupled with matrix-assisted laser desorption/ionization tandem time-of-flight mass spectrometry (MALDI-TOF/TOF-MS) as a qualitative and quantitative technique for the analysis of complicated protein pharmaceutical mixtures was evaluated. Mixtures of Somavert and Miacalcin with a small amount of bovine serum albumin (BSA) as an impurity were analyzed. Both Somavert and Miacalcin were qualitatively identified, and BSA was detected at levels as low as 0.8mol%. Genotropin and Somavert were compared in a single experiment, and all of the distinct amino acid residues from the two proteins were readily identified. Four somatropin drug products (Genotropin, Norditropin, Jintropin, and Omnitrope) were compared using the iTRAQ/MALDI-MS method to determine the similarity between their primary structures and quantify the amount of protein in each product. All four product samples were well labeled and successfully compared when a filtration cleanup step preceded iTRAQ labeling. The quantitative accuracy of the iTRAQ method was evaluated. In all cases, the accuracy of experimentally determined protein ratios was higher than 90%, and the relative standard deviation (RSD) was less than 10%. The iTRAQ and global internal standard technology (GIST) methods were compared, and the iTRAQ method provided both higher sequence coverage and enhanced signal intensity. Published by Elsevier Inc.
Moyers, M F
2014-06-01
Adequate evaluation of the results from multi-institutional trials involving light ion beam treatments requires consideration of the planning margins applied to both targets and organs at risk. A major uncertainty that affects the size of these margins is the conversion of x ray computed tomography numbers (XCTNs) to relative linear stopping powers (RLSPs). Various facilities engaged in multi-institutional clinical trials involving proton beams have been applying significantly different margins in their patient planning. This study was performed to determine the variance in the conversion functions used at proton facilities in the U.S.A. wishing to participate in National Cancer Institute sponsored clinical trials. A simplified method of determining the conversion function was developed using a standard phantom containing only water and aluminum. The new method was based on the premise that all scanners have their XCTNs for air and water calibrated daily to constant values but that the XCTNs for high density/high atomic number materials are variable with different scanning conditions. The standard phantom was taken to 10 different proton facilities and scanned with the local protocols resulting in 14 derived conversion functions which were compared to the conversion functions used at the local facilities. For tissues within ±300 XCTN of water, all facility functions produced converted RLSP values within ±6% of the values produced by the standard function and within 8% of the values from any other facility's function. For XCTNs corresponding to lung tissue, converted RLSP values differed by as great as ±8% from the standard and up to 16% from the values of other facilities. For XCTNs corresponding to low-density immobilization foam, the maximum to minimum values differed by as much as 40%. The new method greatly simplifies determination of the conversion function, reduces ambiguity, and in the future could promote standardization between facilities. Although it was not possible from these experiments to determine which conversion function is most appropriate, the variation between facilities suggests that the margins used in some facilities to account for the uncertainty in converting XCTNs to RLSPs may be too small.
Unmanned aircraft system sense and avoid integrity and continuity
NASA Astrophysics Data System (ADS)
Jamoom, Michael B.
This thesis describes new methods to guarantee safety of sense and avoid (SAA) functions for Unmanned Aircraft Systems (UAS) by evaluating integrity and continuity risks. Previous SAA efforts focused on relative safety metrics, such as risk ratios, comparing the risk of using an SAA system versus not using it. The methods in this thesis evaluate integrity and continuity risks as absolute measures of safety, as is the established practice in commercial aircraft terminal area navigation applications. The main contribution of this thesis is a derivation of a new method, based on a standard intruder relative constant velocity assumption, that uses hazard state estimates and estimate error covariances to establish (1) the integrity risk of the SAA system not detecting imminent loss of '"well clear," which is the time and distance required to maintain safe separation from intruder aircraft, and (2) the probability of false alert, the continuity risk. Another contribution is applying these integrity and continuity risk evaluation methods to set quantifiable and certifiable safety requirements on sensors. A sensitivity analysis uses this methodology to evaluate the impact of sensor errors on integrity and continuity risks. The penultimate contribution is an integrity and continuity risk evaluation where the estimation model is refined to address realistic intruder relative linear accelerations, which goes beyond the current constant velocity standard. The final contribution is an integrity and continuity risk evaluation addressing multiple intruders. This evaluation is a new innovation-based method to determine the risk of mis-associating intruder measurements. A mis-association occurs when the SAA system incorrectly associates a measurement to the wrong intruder, causing large errors in the estimated intruder trajectories. The new methods described in this thesis can help ensure safe encounters between aircraft and enable SAA sensor certification for UAS integration into the National Airspace System.
Neuderth, S; Lukasczik, M; Musekamp, G; Gerlich, C; Saupe-Heide, M; Löbmann, R; Vogel, H
2013-02-01
There so far is no standardized program for external quality assurance in inpatient parent-child prevention and rehabilitation in Germany. Therefore, instruments and methods of external quality assurance were developed and evaluated on behalf of the federal-level health insurance institutions. On the level of structure quality, a modular questionnaire for assessing structural features of rehabilitation/prevention centers, basic and allocation criteria as well as a checklist for visitations were developed. Structural data were collected in a nationwide survey of parent-child prevention and rehabilitation centers. Process and outcome quality data were collected in n=38 centers. Process quality was assessed using multiple methods (process-related structural features, case-related routine documentation, and incident-related patient questionnaires). Outcome quality was measured via patient questionnaires (n=1 799 patients). We used a multi-level modelling approach by adjusting relevant confounders on institutional and patient levels. The methods, instruments and analyzing procedures developed for measuring quality on the level of structure, processes and outcomes were adjusted in cooperation with all relevant stakeholders. Results are exemplarily presented for all quality assurance tools. For most of the risk-adjusted outcome parameters, we found no significant differences between institutions. For the first time, a comprehensive, standardized and generally applicable set of methods and instruments for routine use in comparative quality measurement of inpatient parent-child prevention and rehabilitation is available. However, it should be considered that the very heterogeneous field of family-oriented measures can not be covered entirely by an external quality assurance program. Therefore, methods and instruments have to be adapted continuously to the specifics of this area of health care and to new developments. © Georg Thieme Verlag KG Stuttgart · New York.
Visualization of medical data based on EHR standards.
Kopanitsa, G; Hildebrand, C; Stausberg, J; Englmeier, K H
2013-01-01
To organize an efficient interaction between a doctor and an EHR the data has to be presented in the most convenient way. Medical data presentation methods and models must be flexible in order to cover the needs of the users with different backgrounds and requirements. Most visualization methods are doctor oriented, however, there are indications that the involvement of patients can optimize healthcare. The research aims at specifying the state of the art of medical data visualization. The paper analyzes a number of projects and defines requirements for a generic ISO 13606 based data visualization method. In order to do so it starts with a systematic search for studies on EHR user interfaces. In order to identify best practices visualization methods were evaluated according to the following criteria: limits of application, customizability, re-usability. The visualization methods were compared by using specified criteria. The review showed that the analyzed projects can contribute knowledge to the development of a generic visualization method. However, none of them proposed a model that meets all the necessary criteria for a re-usable standard based visualization method. The shortcomings were mostly related to the structure of current medical concept specifications. The analysis showed that medical data visualization methods use hardcoded GUI, which gives little flexibility. So medical data visualization has to turn from a hardcoded user interface to generic methods. This requires a great effort because current standards are not suitable for organizing the management of visualization data. This contradiction between a generic method and a flexible and user-friendly data layout has to be overcome.
Teaching Group Counseling Skills: Problems and Solutions.
ERIC Educational Resources Information Center
Furr, Susan R.; Barret, Bob
2000-01-01
Discusses the challenges involved in meeting the standards established by the American Counseling Association's Council for the Accreditation of Counseling and Related Education Programs for teaching principles, theories, leadership skills, and group counseling methods for effective group practice. Presents a model involving two courses allowing…
Code of Federal Regulations, 2010 CFR
2010-07-01
... measurement data pairs. Administrator means the Administrator of the Environmental Protection Agency (EPA) or... storing and reporting of information relating to ambient air quality data. Approved regional method (ARM... of an open path analyzer in which a high-concentration test or audit standard gas contained in a...
ISSUES RELATED TO SOLUTION CHEMISTRY IN MERCURY SAMPLING IMPINGERS
Analysis of mercury (Hg) speciation in combustion flue gases is often accomplished in standardized sampling trains in which the sample is passed sequentially through a series of aqueous solutions to capture and separate oxidized Hg (Hg2+) and elemental Hg (Hgo). Such methods incl...
76 FR 28895 - Safety Zone; Ohio River, Sewickley, PA
Federal Register 2010, 2011, 2012, 2013, 2014
2011-05-19
... preamble. Taking of Private Property This rule will not effect a taking of private property or otherwise... Constitutionally Protected Property Rights. Civil Justice Reform This rule meets applicable standards in sections 3... of materials, performance, design, or operation; test methods; sampling procedures; and related...
Addiction Competencies in the 2009 CACREP Clinical Mental Health Counseling Program Standards
ERIC Educational Resources Information Center
Lee, Tiffany K.; Craig, Stephen E.; Fetherson, Bianca T. L.; Simpson, C. Dennis
2013-01-01
The Council for Accreditation of Counseling and Related Educational Programs developed addiction competencies for clinical mental health counseling students. This article highlights these competencies, provides an overview of current addiction training, and describes methods to integrate addiction education into curricula.
41 CFR 60-300.21 - Prohibitions.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 41 Public Contracts and Property Management 1 2013-07-01 2013-07-01 false Prohibitions. 60-300.21 Section 60-300.21 Public Contracts and Property Management Other Provisions Relating to Public Contracts... affect that other party's employees or applicants. (d) Standards, criteria or methods of administration...
7 CFR 226.22 - Procurement standards.
Code of Federal Regulations, 2013 CFR
2013-01-01
... which offerors must fulfill and all other factors to be used in evaluating bids or proposals. (2) Awards... purchase procedures are those relatively simple and informal procurement methods that are sound and... documented business reasons in the best interest of the Program. (3) In competitive negotiation, proposals...
7 CFR 226.22 - Procurement standards.
Code of Federal Regulations, 2012 CFR
2012-01-01
... which offerors must fulfill and all other factors to be used in evaluating bids or proposals. (2) Awards... purchase procedures are those relatively simple and informal procurement methods that are sound and... documented business reasons in the best interest of the Program. (3) In competitive negotiation, proposals...
But Is It Nutritious? Computer Analysis Creates Healthier Meals.
ERIC Educational Resources Information Center
Corrigan, Kathleen A.; Aumann, Margaret B.
1993-01-01
A computerized menu-planning method, "Nutrient Standard Menu Planning" (NSMP), uses today's technology to create healthier menus. Field tested in 20 California school districts, the advantages of NSMP are cost effectiveness, increased flexibility, greater productivity, improved public relations, improved finances, and improved student…
Avila, Mónica; Zougagh, Mohammed; Escarpa, Alberto; Ríos, Angel
2009-10-23
A new, simple and versatile method is presented for the determination of different concentration levels of alkenylbenzenes (eugenol, isoeugenol, eugenol methyl ether, myristicin, anethole and estragole) and the related flavour compounds (coumarin and pulegone) in food samples. The method involves the use of a stationary phase (capillary column) for the enrichment with appropriate elution. After the sample had completely passed through the capillary column the eluent was changed and the separation/detection was achieved. Excellent linearity was obtained under the proposed conditions for a direct determination method and a method including on-line preconcentration. The limits of detection were in the ranges 97-148 and 9.5-14.2 ng/mL, respectively. Evidence for a matrix effect was not found and recoveries between 92 and 110% were obtained. The precision of the method, expressed as relative standard deviation values, was below 5% in all cases. The applicability of this methodology was tested by analyzing synthetic and real food samples.
Correa-de-Araujo, Rosaly; Harris-Love, Michael O; Miljkovic, Iva; Fragala, Maren S; Anthony, Brian W; Manini, Todd M
2017-01-01
A growing body of scientific literature suggests that not only changes in skeletal muscle mass, but also other factors underpinning muscle quality, play a role in the decline in skeletal muscle function and impaired mobility associated with aging. A symposium on muscle quality and the need for standardized assessment was held on April 28, 2016 at the International Conference on Frailty and Sarcopenia Research in Philadelphia, Pennsylvania. The purpose of this symposium was to provide a venue for basic science and clinical researchers and expert clinicians to discuss muscle quality in the context of skeletal muscle function deficit and other aging-related muscle dysfunctions. The present article provides an expanded introduction concerning the emerging definitions of muscle quality and a potential framework for scientific inquiry within the field. Changes in muscle tissue composition, based on excessive levels of inter- and intra-muscular adipose tissue and intramyocellular lipids, have been found to adversely impact metabolism and peak force generation. However, methods to easily and rapidly assess muscle tissue composition in multiple clinical settings and with minimal patient burden are needed. Diagnostic ultrasound and other assessment methods continue to be developed for characterizing muscle pathology, and enhanced sonography using sensors to provide user feedback and improve reliability is currently the subject of ongoing investigation and development. In addition, measures of relative muscle force such as specific force or grip strength adjusted for body size have been proposed as methods to assess changes in muscle quality. Furthermore, performance-based assessments of muscle power via timed tests of function and body size estimates, are associated with lower extremity muscle strength may be responsive to age-related changes in muscle quality. Future aims include reaching consensus on the definition and standardized assessments of muscle quality, and providing recommendations to address critical clinical and technology research gaps within the field.
Siebenhaar, Markus; Küllmer, Kai; Fernandes, Nuno Miguel de Barros; Hüllen, Volker; Hopf, Carsten
2015-09-01
Desorption electrospray ionization (DESI) mass spectrometry is an emerging technology for direct therapeutic drug monitoring in dried blood spots (DBS). Current DBS methods require manual application of small molecules as internal standards for absolute drug quantification. With industrial standardization in mind, we superseded the manual addition of standard and built a three-layer setup for robust quantification of salicylic acid directly from DBS. We combined a dioctyl sodium sulfosuccinate weave facilitating sample spreading with a cellulose layer for addition of isotope-labeled salicylic acid as internal standard and a filter paper for analysis of the standard-containing sample by DESI-MS. Using this setup, we developed a quantification method for salicylic acid from whole blood with a validated linear curve range from 10 to 2000 mg/L, a relative standard deviation (RSD%) ≤14%, and determination coefficients of 0.997. The limit of detection (LOD) was 8 mg/L and the lower limit of quantification (LLOQ) was 10 mg/L. Recovery rates in method verification by LC-MS/MS were 97 to 101% for blinded samples. Most importantly, a study in healthy volunteers after administration of a single dose of Aspirin provides evidence to suggest that the three-layer setup may enable individual pharmacokinetic and endpoint testing following blood collection by finger pricking by patients at home. Taken together, our data suggests that DBS-based quantification of drugs by DESI-MS on pre-manufactured three-layer cartridges may be a promising approach for future near-patient therapeutic drug monitoring.