Sample records for reliability comparative analysis

  1. Reliability on intra-laboratory and inter-laboratory data of hair mineral analysis comparing with blood analysis.

    PubMed

    Namkoong, Sun; Hong, Seung Phil; Kim, Myung Hwa; Park, Byung Cheol

    2013-02-01

    Nowadays, although its clinical value remains controversial institutions utilize hair mineral analysis. Arguments about the reliability of hair mineral analysis persist, and there have been evaluations of commercial laboratories performing hair mineral analysis. The objective of this study was to assess the reliability of intra-laboratory and inter-laboratory data at three commercial laboratories conducting hair mineral analysis, compared to serum mineral analysis. Two divided hair samples taken from near the scalp were submitted for analysis at the same time, to all laboratories, from one healthy volunteer. Each laboratory sent a report consisting of quantitative results and their interpretation of health implications. Differences among intra-laboratory and interlaboratory data were analyzed using SPSS version 12.0 (SPSS Inc., USA). All the laboratories used identical methods for quantitative analysis, and they generated consistent numerical results according to Friedman analysis of variance. However, the normal reference ranges of each laboratory varied. As such, each laboratory interpreted the patient's health differently. On intra-laboratory data, Wilcoxon analysis suggested they generated relatively coherent data, but laboratory B could not in one element, so its reliability was doubtful. In comparison with the blood test, laboratory C generated identical results, but not laboratory A and B. Hair mineral analysis has its limitations, considering the reliability of inter and intra laboratory analysis comparing with blood analysis. As such, clinicians should be cautious when applying hair mineral analysis as an ancillary tool. Each laboratory included in this study requires continuous refinement from now on for inducing standardized normal reference levels.

  2. Comparative Reliability Studies and Analysis of Au, Pd-Coated Cu and Pd-Doped Cu Wire in Microelectronics Packaging

    PubMed Central

    Chong Leong, Gan; Uda, Hashim

    2013-01-01

    This paper compares and discusses the wearout reliability and analysis of Gold (Au), Palladium (Pd) coated Cu and Pd-doped Cu wires used in fineline Ball Grid Array (BGA) package. Intermetallic compound (IMC) thickness measurement has been carried out to estimate the coefficient of diffusion (Do) under various aging conditions of different bonding wires. Wire pull and ball bond shear strengths have been analyzed and we found smaller variation in Pd-doped Cu wire compared to Au and Pd-doped Cu wire. Au bonds were identified to have faster IMC formation, compared to slower IMC growth of Cu. The obtained weibull slope, β of three bonding wires are greater than 1.0 and belong to wearout reliability data point. Pd-doped Cu wire exhibits larger time-to-failure and cycles-to-failure in both wearout reliability tests in Highly Accelerated Temperature and Humidity (HAST) and Temperature Cycling (TC) tests. This proves Pd-doped Cu wire has a greater potential and higher reliability margin compared to Au and Pd-coated Cu wires. PMID:24244344

  3. Reliability of fully automated versus visually controlled pre- and post-processing of resting-state EEG.

    PubMed

    Hatz, F; Hardmeier, M; Bousleiman, H; Rüegg, S; Schindler, C; Fuhr, P

    2015-02-01

    To compare the reliability of a newly developed Matlab® toolbox for the fully automated, pre- and post-processing of resting state EEG (automated analysis, AA) with the reliability of analysis involving visually controlled pre- and post-processing (VA). 34 healthy volunteers (age: median 38.2 (20-49), 82% female) had three consecutive 256-channel resting-state EEG at one year intervals. Results of frequency analysis of AA and VA were compared with Pearson correlation coefficients, and reliability over time was assessed with intraclass correlation coefficients (ICC). Mean correlation coefficient between AA and VA was 0.94±0.07, mean ICC for AA 0.83±0.05 and for VA 0.84±0.07. AA and VA yield very similar results for spectral EEG analysis and are equally reliable. AA is less time-consuming, completely standardized, and independent of raters and their training. Automated processing of EEG facilitates workflow in quantitative EEG analysis. Copyright © 2014 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.

  4. Dynamic decision-making for reliability and maintenance analysis of manufacturing systems based on failure effects

    NASA Astrophysics Data System (ADS)

    Zhang, Ding; Zhang, Yingjie

    2017-09-01

    A framework for reliability and maintenance analysis of job shop manufacturing systems is proposed in this paper. An efficient preventive maintenance (PM) policy in terms of failure effects analysis (FEA) is proposed. Subsequently, reliability evaluation and component importance measure based on FEA are performed under the PM policy. A job shop manufacturing system is applied to validate the reliability evaluation and dynamic maintenance policy. Obtained results are compared with existed methods and the effectiveness is validated. Some vague understandings for issues such as network modelling, vulnerabilities identification, the evaluation criteria of repairable systems, as well as PM policy during manufacturing system reliability analysis are elaborated. This framework can help for reliability optimisation and rational maintenance resources allocation of job shop manufacturing systems.

  5. Laser System Reliability

    DTIC Science & Technology

    1977-03-01

    system acquisition cycle since they provide necessary inputs to comparative analyses, cost/benefit trade -offs, and system simulations. In addition, the...Management Program from above performs the function of analyzing the system trade -offs with respect to reliability to determine a reliability goal...one encounters the problem of comparing present dollars with future dollars. In this analysis, we are trading off costs expended initially (or at

  6. A Comparative Evaluation of Mixed Dentition Analysis on Reliability of Cone Beam Computed Tomography Image Compared to Plaster Model.

    PubMed

    Gowd, Snigdha; Shankar, T; Dash, Samarendra; Sahoo, Nivedita; Chatterjee, Suravi; Mohanty, Pritam

    2017-01-01

    The aim of the study was to evaluate the reliability of cone beam computed tomography (CBCT) obtained image over plaster model for the assessment of mixed dentition analysis. Thirty CBCT-derived images and thirty plaster models were derived from the dental archives, and Moyer's and Tanaka-Johnston analyses were performed. The data obtained were interpreted and analyzed statistically using SPSS 10.0/PC (SPSS Inc., Chicago, IL, USA). Descriptive and analytical analysis along with Student's t -test was performed to qualitatively evaluate the data and P < 0.05 was considered statistically significant. Statistically, significant results were obtained on data comparison between CBCT-derived images and plaster model; the mean for Moyer's analysis in the left and right lower arch for CBCT and plaster model was 21.2 mm, 21.1 mm and 22.5 mm, 22.5 mm, respectively. CBCT-derived images were less reliable as compared to data obtained directly from plaster model for mixed dentition analysis.

  7. Reliability Analysis and Reliability-Based Design Optimization of Circular Composite Cylinders Under Axial Compression

    NASA Technical Reports Server (NTRS)

    Rais-Rohani, Masoud

    2001-01-01

    This report describes the preliminary results of an investigation on component reliability analysis and reliability-based design optimization of thin-walled circular composite cylinders with average diameter and average length of 15 inches. Structural reliability is based on axial buckling strength of the cylinder. Both Monte Carlo simulation and First Order Reliability Method are considered for reliability analysis with the latter incorporated into the reliability-based structural optimization problem. To improve the efficiency of reliability sensitivity analysis and design optimization solution, the buckling strength of the cylinder is estimated using a second-order response surface model. The sensitivity of the reliability index with respect to the mean and standard deviation of each random variable is calculated and compared. The reliability index is found to be extremely sensitive to the applied load and elastic modulus of the material in the fiber direction. The cylinder diameter was found to have the third highest impact on the reliability index. Also the uncertainty in the applied load, captured by examining different values for its coefficient of variation, is found to have a large influence on cylinder reliability. The optimization problem for minimum weight is solved subject to a design constraint on element reliability index. The methodology, solution procedure and optimization results are included in this report.

  8. Rater reliability and concurrent validity of the Keyboard Personal Computer Style instrument (K-PeCS).

    PubMed

    Baker, Nancy A; Cook, James R; Redfern, Mark S

    2009-01-01

    This paper describes the inter-rater and intra-rater reliability, and the concurrent validity of an observational instrument, the Keyboard Personal Computer Style instrument (K-PeCS), which assesses stereotypical postures and movements associated with computer keyboard use. Three trained raters independently rated the video clips of 45 computer keyboard users to ascertain inter-rater reliability, and then re-rated a sub-sample of 15 video clips to ascertain intra-rater reliability. Concurrent validity was assessed by comparing the ratings obtained using the K-PeCS to scores developed from a 3D motion analysis system. The overall K-PeCS had excellent reliability [inter-rater: intra-class correlation coefficients (ICC)=.90; intra-rater: ICC=.92]. Most individual items on the K-PeCS had from good to excellent reliability, although six items fell below ICC=.75. Those K-PeCS items that were assessed for concurrent validity compared favorably to the motion analysis data for all but two items. These results suggest that most items on the K-PeCS can be used to reliably document computer keyboarding style.

  9. Design Optimization Method for Composite Components Based on Moment Reliability-Sensitivity Criteria

    NASA Astrophysics Data System (ADS)

    Sun, Zhigang; Wang, Changxi; Niu, Xuming; Song, Yingdong

    2017-08-01

    In this paper, a Reliability-Sensitivity Based Design Optimization (RSBDO) methodology for the design of the ceramic matrix composites (CMCs) components has been proposed. A practical and efficient method for reliability analysis and sensitivity analysis of complex components with arbitrary distribution parameters are investigated by using the perturbation method, the respond surface method, the Edgeworth series and the sensitivity analysis approach. The RSBDO methodology is then established by incorporating sensitivity calculation model into RBDO methodology. Finally, the proposed RSBDO methodology is applied to the design of the CMCs components. By comparing with Monte Carlo simulation, the numerical results demonstrate that the proposed methodology provides an accurate, convergent and computationally efficient method for reliability-analysis based finite element modeling engineering practice.

  10. Comparative Analysis of the Reliability of Steel Structure with Pinned and Rigid Nodes Subjected to Fire

    NASA Astrophysics Data System (ADS)

    Kubicka, Katarzyna; Radoń, Urszula; Szaniec, Waldemar; Pawlak, Urszula

    2017-10-01

    The paper concerns the reliability analysis of steel structures subjected to high temperatures of fire gases. Two types of spatial structures were analysed, namely with pinned and rigid nodes. The fire analysis was carried out according to prescriptions of Eurocode. The static-strength analysis was conducted using the finite element method (FEM). The MES3D program, developed by Szaniec (Kielce University of Technology, Poland), was used for this purpose. The results received from MES3D made it possible to carry out the reliability analysis using the Numpress Explore program that was developed at the Institute of Fundamental Technological Research of the Polish Academy of Sciences [9]. The measurement of reliability of structures is the Hasofer-Lind reliability index (β). The reliability analysis was carried out according to approximation (FORM, SORM) and simulation (Importance Sampling, Monte Carlo) methods. As the fire progresses, the value of reliability index decreases. The analysis conducted for the study made it possible to evaluate the impact of node types on those changes. In real structures, it is often difficult to define correctly types of nodes, so some simplifications are made. The presented analysis contributes to the recognition of consequences of such assumptions for the safety of structures, subjected to fire.

  11. A Comparative Evaluation of Mixed Dentition Analysis on Reliability of Cone Beam Computed Tomography Image Compared to Plaster Model

    PubMed Central

    Gowd, Snigdha; Shankar, T; Dash, Samarendra; Sahoo, Nivedita; Chatterjee, Suravi; Mohanty, Pritam

    2017-01-01

    Aims and Objective: The aim of the study was to evaluate the reliability of cone beam computed tomography (CBCT) obtained image over plaster model for the assessment of mixed dentition analysis. Materials and Methods: Thirty CBCT-derived images and thirty plaster models were derived from the dental archives, and Moyer's and Tanaka-Johnston analyses were performed. The data obtained were interpreted and analyzed statistically using SPSS 10.0/PC (SPSS Inc., Chicago, IL, USA). Descriptive and analytical analysis along with Student's t-test was performed to qualitatively evaluate the data and P < 0.05 was considered statistically significant. Results: Statistically, significant results were obtained on data comparison between CBCT-derived images and plaster model; the mean for Moyer's analysis in the left and right lower arch for CBCT and plaster model was 21.2 mm, 21.1 mm and 22.5 mm, 22.5 mm, respectively. Conclusion: CBCT-derived images were less reliable as compared to data obtained directly from plaster model for mixed dentition analysis. PMID:28852639

  12. Reliability and concurrent validity of a Smartphone, bubble inclinometer and motion analysis system for measurement of hip joint range of motion.

    PubMed

    Charlton, Paula C; Mentiplay, Benjamin F; Pua, Yong-Hao; Clark, Ross A

    2015-05-01

    Traditional methods of assessing joint range of motion (ROM) involve specialized tools that may not be widely available to clinicians. This study assesses the reliability and validity of a custom Smartphone application for assessing hip joint range of motion. Intra-tester reliability with concurrent validity. Passive hip joint range of motion was recorded for seven different movements in 20 males on two separate occasions. Data from a Smartphone, bubble inclinometer and a three dimensional motion analysis (3DMA) system were collected simultaneously. Intraclass correlation coefficients (ICCs), coefficients of variation (CV) and standard error of measurement (SEM) were used to assess reliability. To assess validity of the Smartphone application and the bubble inclinometer against the three dimensional motion analysis system, intraclass correlation coefficients and fixed and proportional biases were used. The Smartphone demonstrated good to excellent reliability (ICCs>0.75) for four out of the seven movements, and moderate to good reliability for the remaining three movements (ICC=0.63-0.68). Additionally, the Smartphone application displayed comparable reliability to the bubble inclinometer. The Smartphone application displayed excellent validity when compared to the three dimensional motion analysis system for all movements (ICCs>0.88) except one, which displayed moderate to good validity (ICC=0.71). Smartphones are portable and widely available tools that are mostly reliable and valid for assessing passive hip range of motion, with potential for large-scale use when a bubble inclinometer is not available. However, caution must be taken in its implementation as some movement axes demonstrated only moderate reliability. Copyright © 2014 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  13. Reliability and Validity of the Italian Version of the Protocol of Orofacial Myofunctional Evaluation with Scores (I-OMES).

    PubMed

    Scarponi, Letizia; de Felicio, Claudia Maria; Sforza, Chiarella; Pimenta Ferreira, Claudia Lucia; Ginocchio, Daniela; Pizzorni, Nicole; Barozzi, Stefania; Mozzanica, Francesco; Schindler, Antonio

    2018-05-30

    To evaluate the reliability, validity, and responsiveness of the Italian OMES (I-OMES). The study consisted of 3 phases: (1) internal consistency and reliability, (2) validity, and (3) responsiveness analysis. The recruited population included 27 patients with orofacial myofunctional disorders (OMD) and 174 healthy volunteers. Forty-seven subjects, 18 healthy and all recruited patients with OMD were assessed for inter-rater and test-retest reliability analysis. I-OMES and Nordic Orofacial Test - Screening (NOT-S) scores of the patients were correlated for concurrent validity analysis. I-OMES scores from 27 patients with OMD and 27 age- and gender-matched healthy subjects were compared to investigate construct validity. I-OMES scores before and after successful swallowing rehabilitation in patients were compared for responsiveness analysis. Adequate internal consistency (Cronbach α = 0.71) and strong inter-rater and test-retest reliability (intraclass coefficient correlation = 0.97 and 0.98, respectively) were found. I-OMES and NOT-S scores significantly and inversely correlated (r = -0.38). A statistical significance (p < 0.001) was found between the pathological group and the control group for the total I-OMES score. The mean I-OMES score improved from 90 (78-102) to 99 (89-103) after myofunctional rehabilitation (p < 0.001). The I-OMES is a reliable and valid tool to evaluate OMD. © 2018 S. Karger AG, Basel.

  14. Tackling reliability and construct validity: the systematic development of a qualitative protocol for skill and incident analysis.

    PubMed

    Savage, Trevor Nicholas; McIntosh, Andrew Stuart

    2017-03-01

    It is important to understand factors contributing to and directly causing sports injuries to improve the effectiveness and safety of sports skills. The characteristics of injury events must be evaluated and described meaningfully and reliably. However, many complex skills cannot be effectively investigated quantitatively because of ethical, technological and validity considerations. Increasingly, qualitative methods are being used to investigate human movement for research purposes, but there are concerns about reliability and measurement bias of such methods. Using the tackle in Rugby union as an example, we outline a systematic approach for developing a skill analysis protocol with a focus on improving objectivity, validity and reliability. Characteristics for analysis were selected using qualitative analysis and biomechanical theoretical models and epidemiological and coaching literature. An expert panel comprising subject matter experts provided feedback and the inter-rater reliability of the protocol was assessed using ten trained raters. The inter-rater reliability results were reviewed by the expert panel and the protocol was revised and assessed in a second inter-rater reliability study. Mean agreement in the second study improved and was comparable (52-90% agreement and ICC between 0.6 and 0.9) with other studies that have reported inter-rater reliability of qualitative analysis of human movement.

  15. The weakest t-norm based intuitionistic fuzzy fault-tree analysis to evaluate system reliability.

    PubMed

    Kumar, Mohit; Yadav, Shiv Prasad

    2012-07-01

    In this paper, a new approach of intuitionistic fuzzy fault-tree analysis is proposed to evaluate system reliability and to find the most critical system component that affects the system reliability. Here weakest t-norm based intuitionistic fuzzy fault tree analysis is presented to calculate fault interval of system components from integrating expert's knowledge and experience in terms of providing the possibility of failure of bottom events. It applies fault-tree analysis, α-cut of intuitionistic fuzzy set and T(ω) (the weakest t-norm) based arithmetic operations on triangular intuitionistic fuzzy sets to obtain fault interval and reliability interval of the system. This paper also modifies Tanaka et al.'s fuzzy fault-tree definition. In numerical verification, a malfunction of weapon system "automatic gun" is presented as a numerical example. The result of the proposed method is compared with the listing approaches of reliability analysis methods. Copyright © 2012 ISA. Published by Elsevier Ltd. All rights reserved.

  16. Probability techniques for reliability analysis of composite materials

    NASA Technical Reports Server (NTRS)

    Wetherhold, Robert C.; Ucci, Anthony M.

    1994-01-01

    Traditional design approaches for composite materials have employed deterministic criteria for failure analysis. New approaches are required to predict the reliability of composite structures since strengths and stresses may be random variables. This report will examine and compare methods used to evaluate the reliability of composite laminae. The two types of methods that will be evaluated are fast probability integration (FPI) methods and Monte Carlo methods. In these methods, reliability is formulated as the probability that an explicit function of random variables is less than a given constant. Using failure criteria developed for composite materials, a function of design variables can be generated which defines a 'failure surface' in probability space. A number of methods are available to evaluate the integration over the probability space bounded by this surface; this integration delivers the required reliability. The methods which will be evaluated are: the first order, second moment FPI methods; second order, second moment FPI methods; the simple Monte Carlo; and an advanced Monte Carlo technique which utilizes importance sampling. The methods are compared for accuracy, efficiency, and for the conservativism of the reliability estimation. The methodology involved in determining the sensitivity of the reliability estimate to the design variables (strength distributions) and importance factors is also presented.

  17. How to assess and compare inter-rater reliability, agreement and correlation of ratings: an exemplary analysis of mother-father and parent-teacher expressive vocabulary rating pairs

    PubMed Central

    Stolarova, Margarita; Wolf, Corinna; Rinker, Tanja; Brielmann, Aenne

    2014-01-01

    This report has two main purposes. First, we combine well-known analytical approaches to conduct a comprehensive assessment of agreement and correlation of rating-pairs and to dis-entangle these often confused concepts, providing a best-practice example on concrete data and a tutorial for future reference. Second, we explore whether a screening questionnaire developed for use with parents can be reliably employed with daycare teachers when assessing early expressive vocabulary. A total of 53 vocabulary rating pairs (34 parent–teacher and 19 mother–father pairs) collected for two-year-old children (12 bilingual) are evaluated. First, inter-rater reliability both within and across subgroups is assessed using the intra-class correlation coefficient (ICC). Next, based on this analysis of reliability and on the test-retest reliability of the employed tool, inter-rater agreement is analyzed, magnitude and direction of rating differences are considered. Finally, Pearson correlation coefficients of standardized vocabulary scores are calculated and compared across subgroups. The results underline the necessity to distinguish between reliability measures, agreement and correlation. They also demonstrate the impact of the employed reliability on agreement evaluations. This study provides evidence that parent–teacher ratings of children's early vocabulary can achieve agreement and correlation comparable to those of mother–father ratings on the assessed vocabulary scale. Bilingualism of the evaluated child decreased the likelihood of raters' agreement. We conclude that future reports of agreement, correlation and reliability of ratings will benefit from better definition of terms and stricter methodological approaches. The methodological tutorial provided here holds the potential to increase comparability across empirical reports and can help improve research practices and knowledge transfer to educational and therapeutic settings. PMID:24994985

  18. Validation of a novel smartphone accelerometer-based knee goniometer.

    PubMed

    Ockendon, Matthew; Gilbert, Robin E

    2012-09-01

    Loss of full knee extension following anterior cruciate ligament surgery has been shown to impair knee function. However, there can be significant difficulties in accurately and reproducibly measuring a fixed flexion of the knee. We studied the interobserver and the intraobserver reliabilities of a novel, smartphone accelerometer-based, knee goniometer and compared it with a long-armed conventional goniometer for the assessment of fixed flexion knee deformity. Five healthy male volunteers (age range 30 to 40 years) were studied. Measurements of knee flexion angle were made with a telescopic-armed goniometer (Lafayette Instrument, Lafayette, IN) and compared with measurements using the smartphone (iPhone 3GS, Apple Inc., Cupertino, CA) knee goniometer using a novel trigonometric technique based on tibial inclination. Bland-Altman analysis of validity and reliability including statistical analysis of correlation by Pearson's method was undertaken. The iPhone goniometer had an interobserver correlation (r) of 0.994 compared with 0.952 for the Lafayette. The intraobserver correlation was r = 0.982 for the iPhone (compared with 0.927). The datasets from the two instruments correlate closely (r = 0.947) are proportional and have mean difference of only -0.4 degrees (SD 3.86 degrees). The Lafayette goniometer had an intraobserver reliability +/- 9.6 degrees. The interobserver reliability was +/- 8.4 degrees. By comparison the iPhone had an interobserver reliability +/- 2.7 degrees and an intraobserver reliability +/- 4.6 degrees. We found the iPhone goniometer to be a reliable tool for the measurement of subtle knee flexion in the clinic setting.

  19. Detection of myocardial ischemia by automated, motion-corrected, color-encoded perfusion maps compared with visual analysis of adenosine stress cardiovascular magnetic resonance imaging at 3 T: a pilot study.

    PubMed

    Doesch, Christina; Papavassiliu, Theano; Michaely, Henrik J; Attenberger, Ulrike I; Glielmi, Christopher; Süselbeck, Tim; Fink, Christian; Borggrefe, Martin; Schoenberg, Stefan O

    2013-09-01

    The purpose of this study was to compare automated, motion-corrected, color-encoded (AMC) perfusion maps with qualitative visual analysis of adenosine stress cardiovascular magnetic resonance imaging for detection of flow-limiting stenoses. Myocardial perfusion measurements applying the standard adenosine stress imaging protocol and a saturation-recovery temporal generalized autocalibrating partially parallel acquisition (t-GRAPPA) turbo fast low angle shot (Turbo FLASH) magnetic resonance imaging sequence were performed in 25 patients using a 3.0-T MAGNETOM Skyra (Siemens Healthcare Sector, Erlangen, Germany). Perfusion studies were analyzed using AMC perfusion maps and qualitative visual analysis. Angiographically detected coronary artery (CA) stenoses greater than 75% or 50% or more with a myocardial perfusion reserve index less than 1.5 were considered as hemodynamically relevant. Diagnostic performance and time requirement for both methods were compared. Interobserver and intraobserver reliability were also assessed. A total of 29 CA stenoses were included in the analysis. Sensitivity, specificity, positive predictive value, negative predictive value, and accuracy for detection of ischemia on a per-patient basis were comparable using the AMC perfusion maps compared to visual analysis. On a per-CA territory basis, the attribution of an ischemia to the respective vessel was facilitated using the AMC perfusion maps. Interobserver and intraobserver reliability were better for the AMC perfusion maps (concordance correlation coefficient, 0.94 and 0.93, respectively) compared to visual analysis (concordance correlation coefficient, 0.73 and 0.79, respectively). In addition, in comparison to visual analysis, the AMC perfusion maps were able to significantly reduce analysis time from 7.7 (3.1) to 3.2 (1.9) minutes (P < 0.0001). The AMC perfusion maps yielded a diagnostic performance on a per-patient and on a per-CA territory basis comparable with the visual analysis. Furthermore, this approach demonstrated higher interobserver and intraobserver reliability as well as a better time efficiency when compared to visual analysis.

  20. A Comparison of Laser and Video Techniques for Determining Displacement and Velocity during Running

    ERIC Educational Resources Information Center

    Harrison, Andrew J.; Jensen, Randall L.; Donoghue, Orna

    2005-01-01

    The reliability of a laser system was compared with the reliability of a video-based kinematic analysis in measuring displacement and velocity during running. Validity and reliability of the laser on static measures was also assessed at distances between 10 m and 70 m by evaluating the coefficient of variation and intraclass correlation…

  1. Probabilistic Finite Element Analysis & Design Optimization for Structural Designs

    NASA Astrophysics Data System (ADS)

    Deivanayagam, Arumugam

    This study focuses on implementing probabilistic nature of material properties (Kevlar® 49) to the existing deterministic finite element analysis (FEA) of fabric based engine containment system through Monte Carlo simulations (MCS) and implementation of probabilistic analysis in engineering designs through Reliability Based Design Optimization (RBDO). First, the emphasis is on experimental data analysis focusing on probabilistic distribution models which characterize the randomness associated with the experimental data. The material properties of Kevlar® 49 are modeled using experimental data analysis and implemented along with an existing spiral modeling scheme (SMS) and user defined constitutive model (UMAT) for fabric based engine containment simulations in LS-DYNA. MCS of the model are performed to observe the failure pattern and exit velocities of the models. Then the solutions are compared with NASA experimental tests and deterministic results. MCS with probabilistic material data give a good prospective on results rather than a single deterministic simulation results. The next part of research is to implement the probabilistic material properties in engineering designs. The main aim of structural design is to obtain optimal solutions. In any case, in a deterministic optimization problem even though the structures are cost effective, it becomes highly unreliable if the uncertainty that may be associated with the system (material properties, loading etc.) is not represented or considered in the solution process. Reliable and optimal solution can be obtained by performing reliability optimization along with the deterministic optimization, which is RBDO. In RBDO problem formulation, in addition to structural performance constraints, reliability constraints are also considered. This part of research starts with introduction to reliability analysis such as first order reliability analysis, second order reliability analysis followed by simulation technique that are performed to obtain probability of failure and reliability of structures. Next, decoupled RBDO procedure is proposed with a new reliability analysis formulation with sensitivity analysis, which is performed to remove the highly reliable constraints in the RBDO, thereby reducing the computational time and function evaluations. Followed by implementation of the reliability analysis concepts and RBDO in finite element 2D truss problems and a planar beam problem are presented and discussed.

  2. Cross-Cultural Adaptation and Validation of the Italian Version of SWAL-QOL.

    PubMed

    Ginocchio, Daniela; Alfonsi, Enrico; Mozzanica, Francesco; Accornero, Anna Rosa; Bergonzoni, Antonella; Chiarello, Giulia; De Luca, Nicoletta; Farneti, Daniele; Marilia, Simonelli; Calcagno, Paola; Turroni, Valentina; Schindler, Antonio

    2016-10-01

    The aim of the study was to evaluate the reliability and validity of the Italian SWAL-QOL (I-SWAL-QOL). The study consisted of five phases: item generation, reliability analysis, normative data generation, validity analysis, and responsiveness analysis. The item generation phase followed the five-step, cross-cultural, adaptation process of translation and back-translation. A group of 92 dysphagic patients was enrolled for the internal consistency analysis. Seventy-eight patients completed the I-SWAL-QOL twice, 2 weeks apart, for test-retest reliability analysis. A group of 200 asymptomatic subjects completed the I-SWAL-QOL for normative data generation. I-SWAL-QOL scores obtained by both the group of dysphagic subjects and asymptomatic ones were compared for validity analysis. I-SWAL-QOL scores were correlated with SF-36 scores in 67 patients with dysphagia for concurrent validity analysis. Finally, I-SWAL-QOL scores obtained in a group of 30 dysphagic patients before and after successful rehabilitation treatment were compared for responsiveness analysis. All the enrolled patients managed to complete the I-SWAL-QOL without needing any assistance, within 20 min. Internal consistency was acceptable for all I-SWAL-QOL subscales (α > 0.70). Test-retest reliability was also satisfactory for all subscales (ICC > 0.7). A significant difference between the dysphagic group and the control group was found in all I-SWAL-QOL subscales (p < 0.05). Mild to moderate correlations between I-SWAL-QOL and SF-36 subscales were observed. I-SWAL-QOL scores obtained in the pre-treatment condition were significantly lower than those obtained after swallowing rehabilitation. I-SWAL-QOL is reliable, valid, responsive to changes in QOL, and recommended for clinical practice and outcome research.

  3. Improving fMRI reliability in presurgical mapping for brain tumours.

    PubMed

    Stevens, M Tynan R; Clarke, David B; Stroink, Gerhard; Beyea, Steven D; D'Arcy, Ryan Cn

    2016-03-01

    Functional MRI (fMRI) is becoming increasingly integrated into clinical practice for presurgical mapping. Current efforts are focused on validating data quality, with reliability being a major factor. In this paper, we demonstrate the utility of a recently developed approach that uses receiver operating characteristic-reliability (ROC-r) to: (1) identify reliable versus unreliable data sets; (2) automatically select processing options to enhance data quality; and (3) automatically select individualised thresholds for activation maps. Presurgical fMRI was conducted in 16 patients undergoing surgical treatment for brain tumours. Within-session test-retest fMRI was conducted, and ROC-reliability of the patient group was compared to a previous healthy control cohort. Individually optimised preprocessing pipelines were determined to improve reliability. Spatial correspondence was assessed by comparing the fMRI results to intraoperative cortical stimulation mapping, in terms of the distance to the nearest active fMRI voxel. The average ROC-r reliability for the patients was 0.58±0.03, as compared to 0.72±0.02 in healthy controls. For the patient group, this increased significantly to 0.65±0.02 by adopting optimised preprocessing pipelines. Co-localisation of the fMRI maps with cortical stimulation was significantly better for more reliable versus less reliable data sets (8.3±0.9 vs 29±3 mm, respectively). We demonstrated ROC-r analysis for identifying reliable fMRI data sets, choosing optimal postprocessing pipelines, and selecting patient-specific thresholds. Data sets with higher reliability also showed closer spatial correspondence to cortical stimulation. ROC-r can thus identify poor fMRI data at time of scanning, allowing for repeat scans when necessary. ROC-r analysis provides optimised and automated fMRI processing for improved presurgical mapping. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  4. Influence of compact disk recording protocols on reliability and comparability of speech audiometry outcomes: acoustic analysis.

    PubMed

    Di Berardino, F; Tognola, G; Paglialonga, A; Alpini, D; Grandori, F; Cesarani, A

    2010-08-01

    To assess whether different compact disk recording protocols, used to prepare speech test material, affect the reliability and comparability of speech audiometry testing. We conducted acoustic analysis of compact disks used in clinical practice, to determine whether speech material had been recorded using similar procedures. To assess the impact of different recording procedures on speech test outcomes, normal hearing subjects were tested using differently prepared compact disks, and their psychometric curves compared. Acoustic analysis revealed that speech material had been recorded using different protocols. The major difference was the gain between the levels at which the speech material and the calibration signal had been recorded. Although correct calibration of the audiometer was performed for each compact disk before testing, speech recognition thresholds and maximum intelligibility thresholds differed significantly between compact disks (p < 0.05), and were influenced by the gain between the recording level of the speech material and the calibration signal. To ensure the reliability and comparability of speech test outcomes obtained using different compact disks, it is recommended to check for possible differences in the recording gains used to prepare the compact disks, and then to compensate for any differences before testing.

  5. Comparing the Fit of Item Response Theory and Factor Analysis Models

    ERIC Educational Resources Information Center

    Maydeu-Olivares, Alberto; Cai, Li; Hernandez, Adolfo

    2011-01-01

    Linear factor analysis (FA) models can be reliably tested using test statistics based on residual covariances. We show that the same statistics can be used to reliably test the fit of item response theory (IRT) models for ordinal data (under some conditions). Hence, the fit of an FA model and of an IRT model to the same data set can now be…

  6. Reliability of resting-state microstate features in electroencephalography.

    PubMed

    Khanna, Arjun; Pascual-Leone, Alvaro; Farzan, Faranak

    2014-01-01

    Electroencephalographic (EEG) microstate analysis is a method of identifying quasi-stable functional brain states ("microstates") that are altered in a number of neuropsychiatric disorders, suggesting their potential use as biomarkers of neurophysiological health and disease. However, use of EEG microstates as neurophysiological biomarkers requires assessment of the test-retest reliability of microstate analysis. We analyzed resting-state, eyes-closed, 30-channel EEG from 10 healthy subjects over 3 sessions spaced approximately 48 hours apart. We identified four microstate classes and calculated the average duration, frequency, and coverage fraction of these microstates. Using Cronbach's α and the standard error of measurement (SEM) as indicators of reliability, we examined: (1) the test-retest reliability of microstate features using a variety of different approaches; (2) the consistency between TAAHC and k-means clustering algorithms; and (3) whether microstate analysis can be reliably conducted with 19 and 8 electrodes. The approach of identifying a single set of "global" microstate maps showed the highest reliability (mean Cronbach's α > 0.8, SEM ≈ 10% of mean values) compared to microstates derived by each session or each recording. There was notably low reliability in features calculated from maps extracted individually for each recording, suggesting that the analysis is most reliable when maps are held constant. Features were highly consistent across clustering methods (Cronbach's α > 0.9). All features had high test-retest reliability with 19 and 8 electrodes. High test-retest reliability and cross-method consistency of microstate features suggests their potential as biomarkers for assessment of the brain's neurophysiological health.

  7. Reliability of videotaped observational gait analysis in patients with orthopedic impairments

    PubMed Central

    Brunnekreef, Jaap J; van Uden, Caro JT; van Moorsel, Steven; Kooloos, Jan GM

    2005-01-01

    Background In clinical practice, visual gait observation is often used to determine gait disorders and to evaluate treatment. Several reliability studies on observational gait analysis have been described in the literature and generally showed moderate reliability. However, patients with orthopedic disorders have received little attention. The objective of this study is to determine the reliability levels of visual observation of gait in patients with orthopedic disorders. Methods The gait of thirty patients referred to a physical therapist for gait treatment was videotaped. Ten raters, 4 experienced, 4 inexperienced and 2 experts, individually evaluated these videotaped gait patterns of the patients twice, by using a structured gait analysis form. Reliability levels were established by calculating the Intraclass Correlation Coefficient (ICC), using a two-way random design and based on absolute agreement. Results The inter-rater reliability among experienced raters (ICC = 0.42; 95%CI: 0.38–0.46) was comparable to that of the inexperienced raters (ICC = 0.40; 95%CI: 0.36–0.44). The expert raters reached a higher inter-rater reliability level (ICC = 0.54; 95%CI: 0.48–0.60). The average intra-rater reliability of the experienced raters was 0.63 (ICCs ranging from 0.57 to 0.70). The inexperienced raters reached an average intra-rater reliability of 0.57 (ICCs ranging from 0.52 to 0.62). The two expert raters attained ICC values of 0.70 and 0.74 respectively. Conclusion Structured visual gait observation by use of a gait analysis form as described in this study was found to be moderately reliable. Clinical experience appears to increase the reliability of visual gait analysis. PMID:15774012

  8. Development of a Conservative Model Validation Approach for Reliable Analysis

    DTIC Science & Technology

    2015-01-01

    CIE 2015 August 2-5, 2015, Boston, Massachusetts, USA [DRAFT] DETC2015-46982 DEVELOPMENT OF A CONSERVATIVE MODEL VALIDATION APPROACH FOR RELIABLE...obtain a conservative simulation model for reliable design even with limited experimental data. Very little research has taken into account the...3, the proposed conservative model validation is briefly compared to the conventional model validation approach. Section 4 describes how to account

  9. Reliability Block Diagram (RBD) Analysis of NASA Dryden Flight Research Center (DFRC) Flight Termination System and Power Supply

    NASA Technical Reports Server (NTRS)

    Morehouse, Dennis V.

    2006-01-01

    In order to perform public risk analyses for vehicles containing Flight Termination Systems (FTS), it is necessary for the analyst to know the reliability of each of the components of the FTS. These systems are typically divided into two segments; a transmitter system and associated equipment, typically in a ground station or on a support aircraft, and a receiver system and associated equipment on the target vehicle. This analysis attempts to analyze the reliability of the NASA DFRC flight termination system ground transmitter segment for use in the larger risk analysis and to compare the results against two established Department of Defense availability standards for such equipment.

  10. A diameter-sensitive flow entropy method for reliability consideration in water distribution system design

    NASA Astrophysics Data System (ADS)

    Liu, Haixing; Savić, Dragan; Kapelan, Zoran; Zhao, Ming; Yuan, Yixing; Zhao, Hongbin

    2014-07-01

    Flow entropy is a measure of uniformity of pipe flows in water distribution systems. By maximizing flow entropy one can identify reliable layouts or connectivity in networks. In order to overcome the disadvantage of the common definition of flow entropy that does not consider the impact of pipe diameter on reliability, an extended definition of flow entropy, termed as diameter-sensitive flow entropy, is proposed. This new methodology is then assessed by using other reliability methods, including Monte Carlo Simulation, a pipe failure probability model, and a surrogate measure (resilience index) integrated with water demand and pipe failure uncertainty. The reliability assessment is based on a sample of WDS designs derived from an optimization process for each of the two benchmark networks. Correlation analysis is used to evaluate quantitatively the relationship between entropy and reliability. To ensure reliability, a comparative analysis between the flow entropy and the new method is conducted. The results demonstrate that the diameter-sensitive flow entropy shows consistently much stronger correlation with the three reliability measures than simple flow entropy. Therefore, the new flow entropy method can be taken as a better surrogate measure for reliability and could be potentially integrated into the optimal design problem of WDSs. Sensitivity analysis results show that the velocity parameters used in the new flow entropy has no significant impact on the relationship between diameter-sensitive flow entropy and reliability.

  11. An Energy-Based Limit State Function for Estimation of Structural Reliability in Shock Environments

    DOE PAGES

    Guthrie, Michael A.

    2013-01-01

    limit state function is developed for the estimation of structural reliability in shock environments. This limit state function uses peak modal strain energies to characterize environmental severity and modal strain energies at failure to characterize the structural capacity. The Hasofer-Lind reliability index is briefly reviewed and its computation for the energy-based limit state function is discussed. Applications to two degree of freedom mass-spring systems and to a simple finite element model are considered. For these examples, computation of the reliability index requires little effort beyond a modal analysis, but still accounts for relevant uncertainties in both the structure and environment.more » For both examples, the reliability index is observed to agree well with the results of Monte Carlo analysis. In situations where fast, qualitative comparison of several candidate designs is required, the reliability index based on the proposed limit state function provides an attractive metric which can be used to compare and control reliability.« less

  12. Reliability of four models for clinical gait analysis.

    PubMed

    Kainz, Hans; Graham, David; Edwards, Julie; Walsh, Henry P J; Maine, Sheanna; Boyd, Roslyn N; Lloyd, David G; Modenese, Luca; Carty, Christopher P

    2017-05-01

    Three-dimensional gait analysis (3DGA) has become a common clinical tool for treatment planning in children with cerebral palsy (CP). Many clinical gait laboratories use the conventional gait analysis model (e.g. Plug-in-Gait model), which uses Direct Kinematics (DK) for joint kinematic calculations, whereas, musculoskeletal models, mainly used for research, use Inverse Kinematics (IK). Musculoskeletal IK models have the advantage of enabling additional analyses which might improve the clinical decision-making in children with CP. Before any new model can be used in a clinical setting, its reliability has to be evaluated and compared to a commonly used clinical gait model (e.g. Plug-in-Gait model) which was the purpose of this study. Two testers performed 3DGA in eleven CP and seven typically developing participants on two occasions. Intra- and inter-tester standard deviations (SD) and standard error of measurement (SEM) were used to compare the reliability of two DK models (Plug-in-Gait and a six degrees-of-freedom model solved using Vicon software) and two IK models (two modifications of 'gait2392' solved using OpenSim). All models showed good reliability (mean SEM of 3.0° over all analysed models and joint angles). Variations in joint kinetics were less in typically developed than in CP participants. The modified 'gait2392' model which included all the joint rotations commonly reported in clinical 3DGA, showed reasonable reliable joint kinematic and kinetic estimates, and allows additional musculoskeletal analysis on surgically adjustable parameters, e.g. muscle-tendon lengths, and, therefore, is a suitable model for clinical gait analysis. Copyright © 2017. Published by Elsevier B.V.

  13. Reliability analysis of component-level redundant topologies for solid-state fault current limiter

    NASA Astrophysics Data System (ADS)

    Farhadi, Masoud; Abapour, Mehdi; Mohammadi-Ivatloo, Behnam

    2018-04-01

    Experience shows that semiconductor switches in power electronics systems are the most vulnerable components. One of the most common ways to solve this reliability challenge is component-level redundant design. There are four possible configurations for the redundant design in component level. This article presents a comparative reliability analysis between different component-level redundant designs for solid-state fault current limiter. The aim of the proposed analysis is to determine the more reliable component-level redundant configuration. The mean time to failure (MTTF) is used as the reliability parameter. Considering both fault types (open circuit and short circuit), the MTTFs of different configurations are calculated. It is demonstrated that more reliable configuration depends on the junction temperature of the semiconductor switches in the steady state. That junction temperature is a function of (i) ambient temperature, (ii) power loss of the semiconductor switch and (iii) thermal resistance of heat sink. Also, results' sensitivity to each parameter is investigated. The results show that in different conditions, various configurations have higher reliability. The experimental results are presented to clarify the theory and feasibility of the proposed approaches. At last, levelised costs of different configurations are analysed for a fair comparison.

  14. APPLICATION OF TRAVEL TIME RELIABILITY FOR PERFORMANCE ORIENTED OPERATIONAL PLANNING OF EXPRESSWAYS

    NASA Astrophysics Data System (ADS)

    Mehran, Babak; Nakamura, Hideki

    Evaluation of impacts of congestion improvement scheme s on travel time reliability is very significant for road authorities since travel time reliability repr esents operational performance of expressway segments. In this paper, a methodology is presented to estimate travel tim e reliability prior to implementation of congestion relief schemes based on travel time variation modeling as a function of demand, capacity, weather conditions and road accident s. For subject expressway segmen ts, traffic conditions are modeled over a whole year considering demand and capacity as random variables. Patterns of demand and capacity are generated for each five minute interval by appl ying Monte-Carlo simulation technique, and accidents are randomly generated based on a model that links acci dent rate to traffic conditions. A whole year analysis is performed by comparing de mand and available capacity for each scenario and queue length is estimated through shockwave analysis for each time in terval. Travel times are estimated from refined speed-flow relationships developed for intercity expressways and buffer time index is estimated consequently as a measure of travel time reliability. For validation, estimated reliability indices are compared with measured values from empirical data, and it is shown that the proposed method is suitable for operational evaluation and planning purposes.

  15. Cluster-based upper body marker models for three-dimensional kinematic analysis: Comparison with an anatomical model and reliability analysis.

    PubMed

    Boser, Quinn A; Valevicius, Aïda M; Lavoie, Ewen B; Chapman, Craig S; Pilarski, Patrick M; Hebert, Jacqueline S; Vette, Albert H

    2018-04-27

    Quantifying angular joint kinematics of the upper body is a useful method for assessing upper limb function. Joint angles are commonly obtained via motion capture, tracking markers placed on anatomical landmarks. This method is associated with limitations including administrative burden, soft tissue artifacts, and intra- and inter-tester variability. An alternative method involves the tracking of rigid marker clusters affixed to body segments, calibrated relative to anatomical landmarks or known joint angles. The accuracy and reliability of applying this cluster method to the upper body has, however, not been comprehensively explored. Our objective was to compare three different upper body cluster models with an anatomical model, with respect to joint angles and reliability. Non-disabled participants performed two standardized functional upper limb tasks with anatomical and cluster markers applied concurrently. Joint angle curves obtained via the marker clusters with three different calibration methods were compared to those from an anatomical model, and between-session reliability was assessed for all models. The cluster models produced joint angle curves which were comparable to and highly correlated with those from the anatomical model, but exhibited notable offsets and differences in sensitivity for some degrees of freedom. Between-session reliability was comparable between all models, and good for most degrees of freedom. Overall, the cluster models produced reliable joint angles that, however, cannot be used interchangeably with anatomical model outputs to calculate kinematic metrics. Cluster models appear to be an adequate, and possibly advantageous alternative to anatomical models when the objective is to assess trends in movement behavior. Copyright © 2018 Elsevier Ltd. All rights reserved.

  16. Reliability Analysis of a Glacier Lake Warning System Using a Bayesian Net

    NASA Astrophysics Data System (ADS)

    Sturny, Rouven A.; Bründl, Michael

    2013-04-01

    Beside structural mitigation measures like avalanche defense structures, dams and galleries, warning and alarm systems have become important measures for dealing with Alpine natural hazards. Integrating them into risk mitigation strategies and comparing their effectiveness with structural measures requires quantification of the reliability of these systems. However, little is known about how reliability of warning systems can be quantified and which methods are suitable for comparing their contribution to risk reduction with that of structural mitigation measures. We present a reliability analysis of a warning system located in Grindelwald, Switzerland. The warning system was built for warning and protecting residents and tourists from glacier outburst floods as consequence of a rapid drain of the glacier lake. We have set up a Bayesian Net (BN, BPN) that allowed for a qualitative and quantitative reliability analysis. The Conditional Probability Tables (CPT) of the BN were determined according to manufacturer's reliability data for each component of the system as well as by assigning weights for specific BN nodes accounting for information flows and decision-making processes of the local safety service. The presented results focus on the two alerting units 'visual acoustic signal' (VAS) and 'alerting of the intervention entities' (AIE). For the summer of 2009, the reliability was determined to be 94 % for the VAS and 83 % for the AEI. The probability of occurrence of a major event was calculated as 0.55 % per day resulting in an overall reliability of 99.967 % for the VAS and 99.906 % for the AEI. We concluded that a failure of the VAS alerting unit would be the consequence of a simultaneous failure of the four probes located in the lake and the gorge. Similarly, we deduced that the AEI would fail either if there were a simultaneous connectivity loss of the mobile and fixed network in Grindelwald, an Internet access loss or a failure of the regional operations centre. However, the probability of a common failure of these components was assumed to be low. Overall it can be stated that due to numerous redundancies, the investigated warning system is highly reliable and its influence on risk reduction is very high. Comparable studies in the future are needed to classify these results and to gain more experience how the reliability of warning systems could be determined in practice.

  17. Inter-rater reliability for movement pattern analysis (MPA): measuring patterning of behaviors versus discrete behavior counts as indicators of decision-making style

    PubMed Central

    Connors, Brenda L.; Rende, Richard; Colton, Timothy J.

    2014-01-01

    The unique yield of collecting observational data on human movement has received increasing attention in a number of domains, including the study of decision-making style. As such, interest has grown in the nuances of core methodological issues, including the best ways of assessing inter-rater reliability. In this paper we focus on one key topic – the distinction between establishing reliability for the patterning of behaviors as opposed to the computation of raw counts – and suggest that reliability for each be compared empirically rather than determined a priori. We illustrate by assessing inter-rater reliability for key outcome measures derived from movement pattern analysis (MPA), an observational methodology that records body movements as indicators of decision-making style with demonstrated predictive validity. While reliability ranged from moderate to good for raw counts of behaviors reflecting each of two Overall Factors generated within MPA (Assertion and Perspective), inter-rater reliability for patterning (proportional indicators of each factor) was significantly higher and excellent (ICC = 0.89). Furthermore, patterning, as compared to raw counts, provided better prediction of observable decision-making process assessed in the laboratory. These analyses support the utility of using an empirical approach to inform the consideration of measuring patterning versus discrete behavioral counts of behaviors when determining inter-rater reliability of observable behavior. They also speak to the substantial reliability that may be achieved via application of theoretically grounded observational systems such as MPA that reveal thinking and action motivations via visible movement patterns. PMID:24999336

  18. Inter-rater reliability for movement pattern analysis (MPA): measuring patterning of behaviors versus discrete behavior counts as indicators of decision-making style.

    PubMed

    Connors, Brenda L; Rende, Richard; Colton, Timothy J

    2014-01-01

    The unique yield of collecting observational data on human movement has received increasing attention in a number of domains, including the study of decision-making style. As such, interest has grown in the nuances of core methodological issues, including the best ways of assessing inter-rater reliability. In this paper we focus on one key topic - the distinction between establishing reliability for the patterning of behaviors as opposed to the computation of raw counts - and suggest that reliability for each be compared empirically rather than determined a priori. We illustrate by assessing inter-rater reliability for key outcome measures derived from movement pattern analysis (MPA), an observational methodology that records body movements as indicators of decision-making style with demonstrated predictive validity. While reliability ranged from moderate to good for raw counts of behaviors reflecting each of two Overall Factors generated within MPA (Assertion and Perspective), inter-rater reliability for patterning (proportional indicators of each factor) was significantly higher and excellent (ICC = 0.89). Furthermore, patterning, as compared to raw counts, provided better prediction of observable decision-making process assessed in the laboratory. These analyses support the utility of using an empirical approach to inform the consideration of measuring patterning versus discrete behavioral counts of behaviors when determining inter-rater reliability of observable behavior. They also speak to the substantial reliability that may be achieved via application of theoretically grounded observational systems such as MPA that reveal thinking and action motivations via visible movement patterns.

  19. Test-retest reliability of schizoaffective disorder compared with schizophrenia, bipolar disorder, and unipolar depression--a systematic review and meta-analysis.

    PubMed

    Santelmann, Hanno; Franklin, Jeremy; Bußhoff, Jana; Baethge, Christopher

    2015-11-01

    Schizoaffective disorder is a frequent diagnosis, and its reliability is subject to ongoing discussion. We compared the diagnostic reliability of schizoaffective disorder with its main differential diagnoses. We systematically searched Medline, Embase, and PsycInfo for all studies on the test-retest reliability of the diagnosis of schizoaffective disorder as compared with schizophrenia, bipolar disorder, and unipolar depression. We used meta-analytic methods to describe and compare Cohen's kappa as well as positive and negative agreement. In addition, multiple pre-specified and post hoc subgroup and sensitivity analyses were carried out. Out of 4,415 studies screened, 49 studies were included. Test-retest reliability of schizoaffective disorder was consistently lower than that of schizophrenia (in 39 out of 42 studies), bipolar disorder (27/33), and unipolar depression (29/35). The mean difference in kappa between schizoaffective disorder and the other diagnoses was approximately 0.2, and mean Cohen's kappa for schizoaffective disorder was 0.50 (95% confidence interval: 0.40-0.59). While findings were unequivocal and homogeneous for schizoaffective disorder's diagnostic reliability relative to its three main differential diagnoses (dichotomous: smaller versus larger), heterogeneity was substantial for continuous measures, even after subgroup and sensitivity analyses. In clinical practice and research, schizoaffective disorder's comparatively low diagnostic reliability should lead to increased efforts to correctly diagnose the disorder. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  20. Test-retest and between-site reliability in a multicenter fMRI study.

    PubMed

    Friedman, Lee; Stern, Hal; Brown, Gregory G; Mathalon, Daniel H; Turner, Jessica; Glover, Gary H; Gollub, Randy L; Lauriello, John; Lim, Kelvin O; Cannon, Tyrone; Greve, Douglas N; Bockholt, Henry Jeremy; Belger, Aysenil; Mueller, Bryon; Doty, Michael J; He, Jianchun; Wells, William; Smyth, Padhraic; Pieper, Steve; Kim, Seyoung; Kubicki, Marek; Vangel, Mark; Potkin, Steven G

    2008-08-01

    In the present report, estimates of test-retest and between-site reliability of fMRI assessments were produced in the context of a multicenter fMRI reliability study (FBIRN Phase 1, www.nbirn.net). Five subjects were scanned on 10 MRI scanners on two occasions. The fMRI task was a simple block design sensorimotor task. The impulse response functions to the stimulation block were derived using an FIR-deconvolution analysis with FMRISTAT. Six functionally-derived ROIs covering the visual, auditory and motor cortices, created from a prior analysis, were used. Two dependent variables were compared: percent signal change and contrast-to-noise-ratio. Reliability was assessed with intraclass correlation coefficients derived from a variance components analysis. Test-retest reliability was high, but initially, between-site reliability was low, indicating a strong contribution from site and site-by-subject variance. However, a number of factors that can markedly improve between-site reliability were uncovered, including increasing the size of the ROIs, adjusting for smoothness differences, and inclusion of additional runs. By employing multiple steps, between-site reliability for 3T scanners was increased by 123%. Dropping one site at a time and assessing reliability can be a useful method of assessing the sensitivity of the results to particular sites. These findings should provide guidance toothers on the best practices for future multicenter studies.

  1. Reliability Analysis of Sealing Structure of Electromechanical System Based on Kriging Model

    NASA Astrophysics Data System (ADS)

    Zhang, F.; Wang, Y. M.; Chen, R. W.; Deng, W. W.; Gao, Y.

    2018-05-01

    The sealing performance of aircraft electromechanical system has a great influence on flight safety, and the reliability of its typical seal structure is analyzed by researcher. In this paper, we regard reciprocating seal structure as a research object to study structural reliability. Having been based on the finite element numerical simulation method, the contact stress between the rubber sealing ring and the cylinder wall is calculated, and the relationship between the contact stress and the pressure of the hydraulic medium is built, and the friction force on different working conditions are compared. Through the co-simulation, the adaptive Kriging model obtained by EFF learning mechanism is used to describe the failure probability of the seal ring, so as to evaluate the reliability of the sealing structure. This article proposes a new idea of numerical evaluation for the reliability analysis of sealing structure, and also provides a theoretical basis for the optimal design of sealing structure.

  2. Orbiter Autoland reliability analysis

    NASA Technical Reports Server (NTRS)

    Welch, D. Phillip

    1993-01-01

    The Space Shuttle Orbiter is the only space reentry vehicle in which the crew is seated upright. This position presents some physiological effects requiring countermeasures to prevent a crewmember from becoming incapacitated. This also introduces a potential need for automated vehicle landing capability. Autoland is a primary procedure that was identified as a requirement for landing following and extended duration orbiter mission. This report documents the results of the reliability analysis performed on the hardware required for an automated landing. A reliability block diagram was used to evaluate system reliability. The analysis considers the manual and automated landing modes currently available on the Orbiter. (Autoland is presently a backup system only.) Results of this study indicate a +/- 36 percent probability of successfully extending a nominal mission to 30 days. Enough variations were evaluated to verify that the reliability could be altered with missions planning and procedures. If the crew is modeled as being fully capable after 30 days, the probability of a successful manual landing is comparable to that of Autoland because much of the hardware is used for both manual and automated landing modes. The analysis indicates that the reliability for the manual mode is limited by the hardware and depends greatly on crew capability. Crew capability for a successful landing after 30 days has not been determined yet.

  3. [The analytical reliability of clinical laboratory information and role of the standards in its support].

    PubMed

    Men'shikov, V V

    2012-12-01

    The article deals with the factors impacting the reliability of clinical laboratory information. The differences of qualities of laboratory analysis tools produced by various manufacturers are discussed. These characteristics are the causes of discrepancy of the results of laboratory analyses of the same analite. The role of the reference system in supporting the comparability of laboratory analysis results is demonstrated. The project of national standard is presented to regulate the requirements to standards and calibrators for analysis of qualitative and non-metrical characteristics of components of biomaterials.

  4. An improved spanning tree approach for the reliability analysis of supply chain collaborative network

    NASA Astrophysics Data System (ADS)

    Lam, C. Y.; Ip, W. H.

    2012-11-01

    A higher degree of reliability in the collaborative network can increase the competitiveness and performance of an entire supply chain. As supply chain networks grow more complex, the consequences of unreliable behaviour become increasingly severe in terms of cost, effort and time. Moreover, it is computationally difficult to calculate the network reliability of a Non-deterministic Polynomial-time hard (NP-hard) all-terminal network using state enumeration, as this may require a huge number of iterations for topology optimisation. Therefore, this paper proposes an alternative approach of an improved spanning tree for reliability analysis to help effectively evaluate and analyse the reliability of collaborative networks in supply chains and reduce the comparative computational complexity of algorithms. Set theory is employed to evaluate and model the all-terminal reliability of the improved spanning tree algorithm and present a case study of a supply chain used in lamp production to illustrate the application of the proposed approach.

  5. Observation and Classification of Prehension in Preschool Children: A Reliability Study.

    ERIC Educational Resources Information Center

    Moss, S. C.; Hogg, J.

    1981-01-01

    The variety of hand grips of 12 children, most of whom were moderately or severely retarded, were classified in order to begin an analysis of hand function. Test reliability was not as great when items were presented to the children as compared to when children were observed or rated by videotape. (FG)

  6. Sensitivity of wildlife habitat models to uncertainties in GIS data

    NASA Technical Reports Server (NTRS)

    Stoms, David M.; Davis, Frank W.; Cogan, Christopher B.

    1992-01-01

    Decision makers need to know the reliability of output products from GIS analysis. For many GIS applications, it is not possible to compare these products to an independent measure of 'truth'. Sensitivity analysis offers an alternative means of estimating reliability. In this paper, we present a CIS-based statistical procedure for estimating the sensitivity of wildlife habitat models to uncertainties in input data and model assumptions. The approach is demonstrated in an analysis of habitat associations derived from a GIS database for the endangered California condor. Alternative data sets were generated to compare results over a reasonable range of assumptions about several sources of uncertainty. Sensitivity analysis indicated that condor habitat associations are relatively robust, and the results have increased our confidence in our initial findings. Uncertainties and methods described in the paper have general relevance for many GIS applications.

  7. Comparing the reliability of a trigonometric technique to goniometry and inclinometry in measuring ankle dorsiflexion.

    PubMed

    Sidaway, Ben; Euloth, Tracey; Caron, Heather; Piskura, Matthew; Clancy, Jessica; Aide, Alyson

    2012-07-01

    The purpose of this study was to compare the reliability of three previously used techniques for the measurement of ankle dorsiflexion ROM, open-chained goniometry, closed-chained goniometry, and inclinometry, to a novel trigonometric technique. Twenty-one physiotherapy students used four techniques (open-chained goniometry, closed-chained goniometry, inclinometry, and trigonometry) to assess dorsiflexion range of motion in 24 healthy volunteers. All student raters underwent training to establish competence in the four techniques. Raters then measured dorsiflexion with a randomly assigned measuring technique four times over two sessions, one week apart. Data were analyzed using a technique by session analysis of variance, technique measurement variability being the primary index of reliability. Comparisons were also made between the measurements derived from the four techniques and those obtained from a computerized video analysis system. Analysis of the rater measurement variability around the technique means revealed significant differences between techniques with the least variation being found in the trigonometric technique. Significant differences were also found between the technique means but no differences between sessions were evident. The trigonometric technique produced mean ROMs closest in value to those derived from computer analysis. Application of the trigonometric technique resulted in the least variability in measurement across raters and consequently should be considered for use when changes in dorsiflexion ROM need to be reliably assessed. Copyright © 2012 Elsevier B.V. All rights reserved.

  8. Reliability Assessment of Graphite Specimens under Multiaxial Stresses

    NASA Technical Reports Server (NTRS)

    Sookdeo, Steven; Nemeth, Noel N.; Bratton, Robert L.

    2008-01-01

    An investigation was conducted to predict the failure strength response of IG-100 nuclear grade graphite exposed to multiaxial stresses. As part of this effort, a review of failure criteria accounting for the stochastic strength response is provided. The experimental work was performed in the early 1990s at the Oak Ridge National Laboratory (ORNL) on hollow graphite tubes under the action of axial tensile loading and internal pressurization. As part of the investigation, finite-element analysis (FEA) was performed and compared with results of FEA from the original ORNL report. The new analysis generally compared well with the original analysis, although some discrepancies in the location of peak stresses was noted. The Ceramics Analysis and Reliability Evaluation of Structures Life prediction code (CARES/Life) was used with the FEA results to predict the quadrants I (tensile-tensile) and quadrant IV (compression-tension) strength response of the graphite tubes for the principle of independent action (PIA), the Weibull normal stress averaging (NSA), and the Batdorf multiaxial failure theories. The CARES/Life reliability analysis showed that all three failure theories gave similar results in quadrant I but that in quadrant IV, the PIA and Weibull normal stress-averaging theories were not conservative, whereas the Batdorf theory was able to correlate well with experimental results. The conclusion of the study was that the Batdorf theory should generally be used to predict the reliability response of graphite and brittle materials in multiaxial loading situations.

  9. Persian version of frontal assessment battery: Correlations with formal measures of executive functioning and providing normative data for Persian population.

    PubMed

    Asaadi, Sina; Ashrafi, Farzad; Omidbeigi, Mahmoud; Nasiri, Zahra; Pakdaman, Hossein; Amini-Harandi, Ali

    2016-01-05

    Cognitive impairment in patients with Parkinson's disease (PD) mainly involves executive function (EF). The frontal assessment battery (FAB) is an efficient tool for the assessment of EFs. The aims of this study were to determine the validity and reliability of the psychometric properties of the Persian version of FAB and assess its correlation with formal measures of EFs to provide normative data for the Persian version of FAB in patients with PD. The study recruited 149 healthy participants and 49 patients with idiopathic PD. In PD patients, FAB results were compared to their performance on EF tests. Reliability analysis involved test-retest reliability and internal consistency, whereas validity analysis involved convergent validity approach. FAB scores compared in normal controls and in PD patients matched for age, education, and Mini-Mental State Examination (MMSE) score. In PD patients, FAB scores were significantly decreased compared to normal controls, and correlated with Stroop test and Wisconsin Card Sorting Test (WCST). In healthy subjects, FAB scores varied according to the age, education, and MMSE. In the FAB subtest analysis, the performances of PD patients were worse than the healthy participants on similarities, fluency tasks, and Luria's motor series. Persian version of FAB could be used as a reliable scale for the assessment of frontal lobe functions in Iranian patients with PD. Furthermore, normative data provided for the Persian version of this test improve the accuracy and confidence in the clinical application of the FAB.

  10. THE DETERMINATION OF URANIUM BURNUP IN MWD/TON

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rider, B.F.; Russell, J.L. Jr.; Harris, D.W.

    The mass-spectrometric and radiochemical methods for the determination of burn-up in nuclear fuel are compared for reliability in the range of 5000 to 15,000 Mwd/ton. Neither appears to be clearly superior to the other. Each appears to have an uncertainty of approximately 6 to 8%. It is concluded that both methods of analysis should be employed where reliability is of great concern. Agreement between both methods is the best possible indication of reliable results. (auth)

  11. Towards early software reliability prediction for computer forensic tools (case study).

    PubMed

    Abu Talib, Manar

    2016-01-01

    Versatility, flexibility and robustness are essential requirements for software forensic tools. Researchers and practitioners need to put more effort into assessing this type of tool. A Markov model is a robust means for analyzing and anticipating the functioning of an advanced component based system. It is used, for instance, to analyze the reliability of the state machines of real time reactive systems. This research extends the architecture-based software reliability prediction model for computer forensic tools, which is based on Markov chains and COSMIC-FFP. Basically, every part of the computer forensic tool is linked to a discrete time Markov chain. If this can be done, then a probabilistic analysis by Markov chains can be performed to analyze the reliability of the components and of the whole tool. The purposes of the proposed reliability assessment method are to evaluate the tool's reliability in the early phases of its development, to improve the reliability assessment process for large computer forensic tools over time, and to compare alternative tool designs. The reliability analysis can assist designers in choosing the most reliable topology for the components, which can maximize the reliability of the tool and meet the expected reliability level specified by the end-user. The approach of assessing component-based tool reliability in the COSMIC-FFP context is illustrated with the Forensic Toolkit Imager case study.

  12. Reliability and coverage analysis of non-repairable fault-tolerant memory systems

    NASA Technical Reports Server (NTRS)

    Cox, G. W.; Carroll, B. D.

    1976-01-01

    A method was developed for the construction of probabilistic state-space models for nonrepairable systems. Models were developed for several systems which achieved reliability improvement by means of error-coding, modularized sparing, massive replication and other fault-tolerant techniques. From the models developed, sets of reliability and coverage equations for the systems were developed. Comparative analyses of the systems were performed using these equation sets. In addition, the effects of varying subunit reliabilities on system reliability and coverage were described. The results of these analyses indicated that a significant gain in system reliability may be achieved by use of combinations of modularized sparing, error coding, and software error control. For sufficiently reliable system subunits, this gain may far exceed the reliability gain achieved by use of massive replication techniques, yet result in a considerable saving in system cost.

  13. NASA trend analysis procedures

    NASA Technical Reports Server (NTRS)

    1993-01-01

    This publication is primarily intended for use by NASA personnel engaged in managing or implementing trend analysis programs. 'Trend analysis' refers to the observation of current activity in the context of the past in order to infer the expected level of future activity. NASA trend analysis was divided into 5 categories: problem, performance, supportability, programmatic, and reliability. Problem trend analysis uncovers multiple occurrences of historical hardware or software problems or failures in order to focus future corrective action. Performance trend analysis observes changing levels of real-time or historical flight vehicle performance parameters such as temperatures, pressures, and flow rates as compared to specification or 'safe' limits. Supportability trend analysis assesses the adequacy of the spaceflight logistics system; example indicators are repair-turn-around time and parts stockage levels. Programmatic trend analysis uses quantitative indicators to evaluate the 'health' of NASA programs of all types. Finally, reliability trend analysis attempts to evaluate the growth of system reliability based on a decreasing rate of occurrence of hardware problems over time. Procedures for conducting all five types of trend analysis are provided in this publication, prepared through the joint efforts of the NASA Trend Analysis Working Group.

  14. Pulse oximeter sensor application during neonatal resuscitation: a randomized controlled trial.

    PubMed

    Louis, Deepak; Sundaram, Venkataseshan; Kumar, Praveen

    2014-03-01

    This study was done to compare 2 techniques of pulse oximeter sensor application during neonatal resuscitation for faster signal detection. Sensor to infant first (STIF) and then to oximeter was compared with sensor to oximeter first (STOF) and then to infant in ≥28 weeks gestations. The primary outcome was time from completion of sensor application to reliable signal, defined as stable display of heart rate and saturation. Time from birth to sensor application, time taken for sensor application, time from birth to reliable signal, and need to reapply sensor were secondary outcomes. An intention-to-treat analysis was done, and subgroup analysis was done for gestation and need for resuscitation. One hundred fifty neonates were randomized with 75 to each technique. The median (IQR) time from sensor application to detection of reliable signal was longer in STIF group compared with STOF group (16 [15-17] vs. 10 [6-18] seconds; P <0.001). Time taken for application of sensor was longer with STIF technique than with STOF technique (12 [10-16] vs. 11 [9-15] seconds; P = 0.04). Time from birth to reliable signal did not differ between the 2 methods (STIF: 61 [52-76] seconds; STOF: 58 [47-73] seconds [P = .09]). Time taken for signal acquisition was longer with STIF than with STOF in both subgroups. In the delivery room setting, the STOF method recognized saturation and heart rate faster than the STIF method. The time from birth to reliable signal was similar with the 2 methods.

  15. Comparing Methods for Assessing Reliability Uncertainty Based on Pass/Fail Data Collected Over Time

    DOE PAGES

    Abes, Jeff I.; Hamada, Michael S.; Hills, Charles R.

    2017-12-20

    In this paper, we compare statistical methods for analyzing pass/fail data collected over time; some methods are traditional and one (the RADAR or Rationale for Assessing Degradation Arriving at Random) was recently developed. These methods are used to provide uncertainty bounds on reliability. We make observations about the methods' assumptions and properties. Finally, we illustrate the differences between two traditional methods, logistic regression and Weibull failure time analysis, and the RADAR method using a numerical example.

  16. Comparing Methods for Assessing Reliability Uncertainty Based on Pass/Fail Data Collected Over Time

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Abes, Jeff I.; Hamada, Michael S.; Hills, Charles R.

    In this paper, we compare statistical methods for analyzing pass/fail data collected over time; some methods are traditional and one (the RADAR or Rationale for Assessing Degradation Arriving at Random) was recently developed. These methods are used to provide uncertainty bounds on reliability. We make observations about the methods' assumptions and properties. Finally, we illustrate the differences between two traditional methods, logistic regression and Weibull failure time analysis, and the RADAR method using a numerical example.

  17. Smile line assessment comparing quantitative measurement and visual estimation.

    PubMed

    Van der Geld, Pieter; Oosterveld, Paul; Schols, Jan; Kuijpers-Jagtman, Anne Marie

    2011-02-01

    Esthetic analysis of dynamic functions such as spontaneous smiling is feasible by using digital videography and computer measurement for lip line height and tooth display. Because quantitative measurements are time-consuming, digital videography and semiquantitative (visual) estimation according to a standard categorization are more practical for regular diagnostics. Our objective in this study was to compare 2 semiquantitative methods with quantitative measurements for reliability and agreement. The faces of 122 male participants were individually registered by using digital videography. Spontaneous and posed smiles were captured. On the records, maxillary lip line heights and tooth display were digitally measured on each tooth and also visually estimated according to 3-grade and 4-grade scales. Two raters were involved. An error analysis was performed. Reliability was established with kappa statistics. Interexaminer and intraexaminer reliability values were high, with median kappa values from 0.79 to 0.88. Agreement of the 3-grade scale estimation with quantitative measurement showed higher median kappa values (0.76) than the 4-grade scale estimation (0.66). Differentiating high and gummy smile lines (4-grade scale) resulted in greater inaccuracies. The estimation of a high, average, or low smile line for each tooth showed high reliability close to quantitative measurements. Smile line analysis can be performed reliably with a 3-grade scale (visual) semiquantitative estimation. For a more comprehensive diagnosis, additional measuring is proposed, especially in patients with disproportional gingival display. Copyright © 2011 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.

  18. Comparing the Psychometric Properties of Two Physical Activity Self-Efficacy Instruments in Urban, Adolescent Girls: Validity, Measurement Invariance, and Reliability

    PubMed Central

    Voskuil, Vicki R.; Pierce, Steven J.; Robbins, Lorraine B.

    2017-01-01

    Aims: This study compared the psychometric properties of two self-efficacy instruments related to physical activity. Factorial validity, cross-group and longitudinal invariance, and composite reliability were examined. Methods: Secondary analysis was conducted on data from a group randomized controlled trial investigating the effect of a 17-week intervention on increasing moderate to vigorous physical activity among 5th–8th grade girls (N = 1,012). Participants completed a 6-item Physical Activity Self-Efficacy Scale (PASE) and a 7-item Self-Efficacy for Exercise Behaviors Scale (SEEB) at baseline and post-intervention. Confirmatory factor analyses for intervention and control groups were conducted with Mplus Version 7.4 using robust weighted least squares estimation. Model fit was evaluated with the chi-square index, comparative fit index, and root mean square error of approximation. Composite reliability for latent factors with ordinal indicators was computed from Mplus output using SAS 9.3. Results: Mean age of the girls was 12.2 years (SD = 0.96). One-third of the girls were obese. Girls represented a diverse sample with over 50% indicating black race and an additional 19% identifying as mixed or other race. Both instruments demonstrated configural invariance for simultaneous analysis of cross-group and longitudinal invariance based on alternative fit indices. However, simultaneous metric invariance was not met for the PASE or the SEEB instruments. Partial metric invariance for the simultaneous analysis was achieved for the PASE with one factor loading identified as non-invariant. Partial metric invariance was not met for the SEEB. Longitudinal scalar invariance was achieved for both instruments in the control group but not the intervention group. Composite reliability for the PASE ranged from 0.772 to 0.842. Reliability for the SEEB ranged from 0.719 to 0.800 indicating higher reliability for the PASE. Reliability was more stable over time in the control group for both instruments. Conclusions: Results suggest that the intervention influenced how girls responded to indicator items. Neither of the instruments achieved simultaneous metric invariance making it difficult to assess mean differences in PA self-efficacy between groups. PMID:28824487

  19. Reliability of measuring sciatic and tibial nerve movement with diagnostic ultrasound during a neural mobilisation technique.

    PubMed

    Ellis, Richard; Hing, Wayne; Dilley, Andrew; McNair, Peter

    2008-08-01

    Diagnostic ultrasound provides a technique whereby real-time, in vivo analysis of peripheral nerve movement is possible. This study measured sciatic nerve movement during a "slider" neural mobilisation technique (ankle dorsiflexion/plantar flexion and cervical extension/flexion). Transverse and longitudinal movement was assessed from still ultrasound images and video sequences by using frame-by-frame cross-correlation software. Sciatic nerve movement was recorded in the transverse and longitudinal planes. For transverse movement, at the posterior midthigh (PMT) the mean value of lateral sciatic nerve movement was 3.54 mm (standard error of measurement [SEM] +/- 1.18 mm) compared with anterior-posterior/vertical (AP) movement of 1.61 mm (SEM +/- 0.78 mm). At the popliteal crease (PC) scanning location, lateral movement was 6.62 mm (SEM +/- 1.10 mm) compared with AP movement of 3.26 mm (SEM +/- 0.99 mm). Mean longitudinal sciatic nerve movement at the PMT was 3.47 mm (SEM +/- 0.79 mm; n = 27) compared with the PC of 5.22 mm (SEM +/- 0.05 mm; n = 3). The reliability of ultrasound measurement of transverse sciatic nerve movement was fair to excellent (Intraclass correlation coefficient [ICC] = 0.39-0.76) compared with excellent (ICC = 0.75) for analysis of longitudinal movement. Diagnostic ultrasound presents a reliable, noninvasive, real-time, in vivo method for analysis of sciatic nerve movement.

  20. Developing safety performance functions incorporating reliability-based risk measures.

    PubMed

    Ibrahim, Shewkar El-Bassiouni; Sayed, Tarek

    2011-11-01

    Current geometric design guides provide deterministic standards where the safety margin of the design output is generally unknown and there is little knowledge of the safety implications of deviating from these standards. Several studies have advocated probabilistic geometric design where reliability analysis can be used to account for the uncertainty in the design parameters and to provide a risk measure of the implication of deviation from design standards. However, there is currently no link between measures of design reliability and the quantification of safety using collision frequency. The analysis presented in this paper attempts to bridge this gap by incorporating a reliability-based quantitative risk measure such as the probability of non-compliance (P(nc)) in safety performance functions (SPFs). Establishing this link will allow admitting reliability-based design into traditional benefit-cost analysis and should lead to a wider application of the reliability technique in road design. The present application is concerned with the design of horizontal curves, where the limit state function is defined in terms of the available (supply) and stopping (demand) sight distances. A comprehensive collision and geometric design database of two-lane rural highways is used to investigate the effect of the probability of non-compliance on safety. The reliability analysis was carried out using the First Order Reliability Method (FORM). Two Negative Binomial (NB) SPFs were developed to compare models with and without the reliability-based risk measures. It was found that models incorporating the P(nc) provided a better fit to the data set than the traditional (without risk) NB SPFs for total, injury and fatality (I+F) and property damage only (PDO) collisions. Copyright © 2011 Elsevier Ltd. All rights reserved.

  1. QuickView video preview software of colon capsule endoscopy: reliability in presenting colorectal polyps as compared to normal mode reading.

    PubMed

    Farnbacher, Michael J; Krause, Horst H; Hagel, Alexander F; Raithel, Martin; Neurath, Markus F; Schneider, Thomas

    2014-03-01

    OBJECTIVE. Colon capsule endoscopy (CCE) proved to be highly sensitive in detection of colorectal polyps (CP). Major limitation is the time-consuming video reading. The aim of this prospective, double-center study was to assess the theoretical time-saving potential and its possible impact on the reliability of "QuickView" (QV), in the presentation of CP as compared to normal mode (NM). METHODS. During NM reading of 65 CCE videos (mean patient´s age 56 years), all frames showing CPs were collected and compared to the number of frames presented by QV at increasing QV settings (10, 20, ... 80%). Reliability of QV in presenting polyps <6 mm and ≥6 mm (significant polyp), and identifying patients for subsequent therapeutic colonoscopy, capsule egestion rate, cleansing level, and estimated time-saving potential were assessed. RESULTS. At a 30% QV setting, the QV video presented 89% of the significant polyps and 86% of any polyps with ≥1 frame (per-polyp analysis) identified in NM before. At a 10% QV setting, 98% of the 52 patients with significant polyps could be identified (per-patient analysis) by QV video analysis. Capsule excretion rate was 74% and colon cleanliness was adequate in 85%. QV´s presentation rate correlates to the QV setting, the polyp size, and the number of frames per finding. CONCLUSIONS. Depending on its setting, the reliability of QV in presenting CP as compared to NM reading is notable. However, if no significant polyp is presented by QV, NM reading must be performed afterwards. The reduction of frames to be analyzed in QV might speed up identification of candidates for therapeutic colonoscopy.

  2. Optimization Based Efficiencies in First Order Reliability Analysis

    NASA Technical Reports Server (NTRS)

    Peck, Jeffrey A.; Mahadevan, Sankaran

    2003-01-01

    This paper develops a method for updating the gradient vector of the limit state function in reliability analysis using Broyden's rank one updating technique. In problems that use commercial code as a black box, the gradient calculations are usually done using a finite difference approach, which becomes very expensive for large system models. The proposed method replaces the finite difference gradient calculations in a standard first order reliability method (FORM) with Broyden's Quasi-Newton technique. The resulting algorithm of Broyden updates within a FORM framework (BFORM) is used to run several example problems, and the results compared to standard FORM results. It is found that BFORM typically requires fewer functional evaluations that FORM to converge to the same answer.

  3. Test-retest reliability of computer-based video analysis of general movements in healthy term-born infants.

    PubMed

    Valle, Susanne Collier; Støen, Ragnhild; Sæther, Rannei; Jensenius, Alexander Refsum; Adde, Lars

    2015-10-01

    A computer-based video analysis has recently been presented for quantitative assessment of general movements (GMs). This method's test-retest reliability, however, has not yet been evaluated. The aim of the current study was to evaluate the test-retest reliability of computer-based video analysis of GMs, and to explore the association between computer-based video analysis and the temporal organization of fidgety movements (FMs). Test-retest reliability study. 75 healthy, term-born infants were recorded twice the same day during the FMs period using a standardized video set-up. The computer-based movement variables "quantity of motion mean" (Qmean), "quantity of motion standard deviation" (QSD) and "centroid of motion standard deviation" (CSD) were analyzed, reflecting the amount of motion and the variability of the spatial center of motion of the infant, respectively. In addition, the association between the variable CSD and the temporal organization of FMs was explored. Intraclass correlation coefficients (ICC 1.1 and ICC 3.1) were calculated to assess test-retest reliability. The ICC values for the variables CSD, Qmean and QSD were 0.80, 0.80 and 0.86 for ICC (1.1), respectively; and 0.80, 0.86 and 0.90 for ICC (3.1), respectively. There were significantly lower CSD values in the recordings with continual FMs compared to the recordings with intermittent FMs (p<0.05). This study showed high test-retest reliability of computer-based video analysis of GMs, and a significant association between our computer-based video analysis and the temporal organization of FMs. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  4. An instrument to characterize the environment for residents' evidence-based medicine learning and practice.

    PubMed

    Mi, Misa; Moseley, James L; Green, Michael L

    2012-02-01

    Many residency programs offer training in evidence-based medicine (EBM). However, these curricula often fail to achieve optimal learning outcomes, perhaps because they neglect various contextual factors in the learning environment. We developed and validated an instrument to characterize the environment for EBM learning and practice in residency programs. An EBM Environment Scale was developed following scale development principles. A survey was administered to residents across six programs in primary care specialties at four medical centers. Internal consistency reliability was analyzed with Cronbach's coefficient alpha. Validity was assessed by comparing predetermined subscales with the survey's internal structure as assessed via factor analysis. Scores were also compared for subgroups based on residency program affiliation and residency characteristics. Out of 262 eligible residents, 124 completed the survey (response rate 47%). The overall mean score was 3.89 (standard deviation=0.56). The initial reliability analysis of the 48-item scale had a high reliability coefficient (Cronbach α=.94). Factor analysis and further item analysis resulted in a shorter 36-item scale with a satisfactory reliability coefficient (Cronbach α=.86). Scores were higher for residents with prior EBM training in medical school (4.14 versus 3.62) and in residency (4.25 versus 3.69). If further testing confirms its properties, the EBM Environment Scale may be used to understand the influence of the learning environment on the effectiveness of EBM training. Additionally, it may detect changes in the EBM learning environment in response to programmatic or institutional interventions.

  5. Interrater reliability of schizoaffective disorder compared with schizophrenia, bipolar disorder, and unipolar depression - A systematic review and meta-analysis.

    PubMed

    Santelmann, Hanno; Franklin, Jeremy; Bußhoff, Jana; Baethge, Christopher

    2016-10-01

    Schizoaffective disorder is a common diagnosis in clinical practice but its nosological status has been subject to debate ever since it was conceptualized. Although it is key that diagnostic reliability is sufficient, schizoaffective disorder has been reported to have low interrater reliability. Evidence based on systematic review and meta-analysis methods, however, is lacking. Using a highly sensitive literature search in Medline, Embase, and PsycInfo we identified studies measuring the interrater reliability of schizoaffective disorder in comparison to schizophrenia, bipolar disorder, and unipolar disorder. Out of 4126 records screened we included 25 studies reporting on 7912 patients diagnosed by different raters. The interrater reliability of schizoaffective disorder was moderate (meta-analytic estimate of Cohen's kappa 0.57 [95% CI: 0.41-0.73]), and substantially lower than that of its main differential diagnoses (difference in kappa between 0.22 and 0.19). Although there was considerable heterogeneity, analyses revealed that the interrater reliability of schizoaffective disorder was consistently lower in the overwhelming majority of studies. The results remained robust in subgroup and sensitivity analyses (e.g., diagnostic manual used) as well as in meta-regressions (e.g., publication year) and analyses of publication bias. Clinically, the results highlight the particular importance of diagnostic re-evaluation in patients diagnosed with schizoaffective disorder. They also quantify a widely held clinical impression of lower interrater reliability and agree with earlier meta-analysis reporting low test-retest reliability. Copyright © 2016. Published by Elsevier B.V.

  6. Strategy for reliable strain measurement in InAs/GaAs materials from high-resolution Z-contrast STEM images

    NASA Astrophysics Data System (ADS)

    Vatanparast, Maryam; Vullum, Per Erik; Nord, Magnus; Zuo, Jian-Min; Reenaas, Turid W.; Holmestad, Randi

    2017-09-01

    Geometric phase analysis (GPA), a fast and simple Fourier space method for strain analysis, can give useful information on accumulated strain and defect propagation in multiple layers of semiconductors, including quantum dot materials. In this work, GPA has been applied to high resolution Z-contrast scanning transmission electron microscopy (STEM) images. Strain maps determined from different g vectors of these images are compared to each other, in order to analyze and assess the GPA technique in terms of accuracy. The SmartAlign tool has been used to improve the STEM image quality getting more reliable results. Strain maps from template matching as a real space approach are compared with strain maps from GPA, and it is discussed that a real space analysis is a better approach than GPA for aberration corrected STEM images.

  7. Validation of the Practice Environment Scale to the Brazilian culture.

    PubMed

    Gasparino, Renata C; Guirardello, Edinêis de B

    2017-07-01

    To validate the Brazilian version of the Practice Environment Scale. The Practice Environment Scale is a tool that evaluates the presence of characteristics that are favourable for professional nursing practice because a better work environment contributes to positive results for patients, professionals and institutions. Methodological study including 209 nurses. Validity was assessed via a confirmatory factor analysis using structural equation modelling, in which the correlations between the instrument and the following variables were tested: burnout, job satisfaction, safety climate, perception of quality of care and intention to leave the job. Subgroups were compared and the reliability was assessed using Cronbach's alpha and the composite reliability. Factor analysis resulted in exclusion of seven items. Significant correlations were obtained between the subscales and all variables in the study. The reliability was considered acceptable. The Brazilian version of the Practice Environment Scale is a valid and reliable tool used to assess the characteristics that promote professional nursing practice. Use of this tool in Brazilian culture should allow managers to implement changes that contribute to the achievement of better results, in addition to identifying and comparing the environments of health institutions. © 2017 John Wiley & Sons Ltd.

  8. The Validation of a Case-Based, Cumulative Assessment and Progressions Examination

    PubMed Central

    Coker, Adeola O.; Copeland, Jeffrey T.; Gottlieb, Helmut B.; Horlen, Cheryl; Smith, Helen E.; Urteaga, Elizabeth M.; Ramsinghani, Sushma; Zertuche, Alejandra; Maize, David

    2016-01-01

    Objective. To assess content and criterion validity, as well as reliability of an internally developed, case-based, cumulative, high-stakes third-year Annual Student Assessment and Progression Examination (P3 ASAP Exam). Methods. Content validity was assessed through the writing-reviewing process. Criterion validity was assessed by comparing student scores on the P3 ASAP Exam with the nationally validated Pharmacy Curriculum Outcomes Assessment (PCOA). Reliability was assessed with psychometric analysis comparing student performance over four years. Results. The P3 ASAP Exam showed content validity through representation of didactic courses and professional outcomes. Similar scores on the P3 ASAP Exam and PCOA with Pearson correlation coefficient established criterion validity. Consistent student performance using Kuder-Richardson coefficient (KR-20) since 2012 reflected reliability of the examination. Conclusion. Pharmacy schools can implement internally developed, high-stakes, cumulative progression examinations that are valid and reliable using a robust writing-reviewing process and psychometric analyses. PMID:26941435

  9. A Meta-Analysis of the Reliability of Free and For-Pay Big Five Scales.

    PubMed

    Hamby, Tyler; Taylor, Wyn; Snowden, Audrey K; Peterson, Robert A

    2016-01-01

    The present study meta-analytically compared coefficient alpha reliabilities reported for free and for-pay Big Five scales. We collected 288 studies from five previous meta-analyses of Big Five traits and harvested 1,317 alphas from these studies. We found that free and for-pay scales measuring Big Five traits possessed comparable reliabilities. However, after we controlled for the numbers of items in the scales with the Spearman-Brown formula, we found that free scales possessed significantly higher alpha coefficients than for-pay scales for each of the Big Five traits. Thus, the study offers initial evidence that Big Five scales that are free more efficiently measure these traits for research purposes than do for-pay scales.

  10. Graph Theoretical Analysis of Functional Brain Networks: Test-Retest Evaluation on Short- and Long-Term Resting-State Functional MRI Data

    PubMed Central

    Wang, Jin-Hui; Zuo, Xi-Nian; Gohel, Suril; Milham, Michael P.; Biswal, Bharat B.; He, Yong

    2011-01-01

    Graph-based computational network analysis has proven a powerful tool to quantitatively characterize functional architectures of the brain. However, the test-retest (TRT) reliability of graph metrics of functional networks has not been systematically examined. Here, we investigated TRT reliability of topological metrics of functional brain networks derived from resting-state functional magnetic resonance imaging data. Specifically, we evaluated both short-term (<1 hour apart) and long-term (>5 months apart) TRT reliability for 12 global and 6 local nodal network metrics. We found that reliability of global network metrics was overall low, threshold-sensitive and dependent on several factors of scanning time interval (TI, long-term>short-term), network membership (NM, networks excluding negative correlations>networks including negative correlations) and network type (NT, binarized networks>weighted networks). The dependence was modulated by another factor of node definition (ND) strategy. The local nodal reliability exhibited large variability across nodal metrics and a spatially heterogeneous distribution. Nodal degree was the most reliable metric and varied the least across the factors above. Hub regions in association and limbic/paralimbic cortices showed moderate TRT reliability. Importantly, nodal reliability was robust to above-mentioned four factors. Simulation analysis revealed that global network metrics were extremely sensitive (but varying degrees) to noise in functional connectivity and weighted networks generated numerically more reliable results in compared with binarized networks. For nodal network metrics, they showed high resistance to noise in functional connectivity and no NT related differences were found in the resistance. These findings provide important implications on how to choose reliable analytical schemes and network metrics of interest. PMID:21818285

  11. Strength and reliability analysis of metal-composite overwrapped pressure vessel

    NASA Astrophysics Data System (ADS)

    Burov, A. E.; Lepikhin, A. M.; Moskvichev, V. V.

    2017-12-01

    Metal-composite overwrapped pressure vessels (MCOPV) have found a wide application in aerospace and aeronautical industries. Such vessels should combine impermeability and high weight efficiency with enhanced long-term safety and durability. To meet these requirements, theoretical and experimental studies on the mechanics of deformation and failure of MCOPV are required. In the paper, the analysis on strength, lifetime and reliability of MCOPV is presented. A high performance of the MCOPV is justified by comparing the calculation results with experiment data obtained on full-scale samples.

  12. Effects of test method and participant musical training on preference ratings of stimuli with different reverberation times.

    PubMed

    Lawless, Martin S; Vigeant, Michelle C

    2017-10-01

    Selecting an appropriate listening test design for concert hall research depends on several factors, including listening test method and participant critical-listening experience. Although expert listeners afford more reliable data, their perceptions may not be broadly representative. The present paper contains two studies that examined the validity and reliability of the data obtained from two listening test methods, a successive and a comparative method, and two types of participants, musicians and non-musicians. Participants rated their overall preference of auralizations generated from eight concert hall conditions with a range of reverberation times (0.0-7.2 s). Study 1, with 34 participants, assessed the two methods. The comparative method yielded similar results and reliability as the successive method. Additionally, the comparative method was rated as less difficult and more preferable. For study 2, an additional 37 participants rated the stimuli using the comparative method only. An analysis of variance of the responses from both studies revealed that musicians are better than non-musicians at discerning their preferences across stimuli. This result was confirmed with a k-means clustering analysis on the entire dataset that revealed five preference groups. Four groups exhibited clear preferences to the stimuli, while the fifth group, predominantly comprising non-musicians, demonstrated no clear preference.

  13. The Movement Imagery Questionnaire-Revised, Second Edition (MIQ-RS) Is a Reliable and Valid Tool for Evaluating Motor Imagery in Stroke Populations

    PubMed Central

    Butler, Andrew J.; Cazeaux, Jennifer; Fidler, Anna; Jansen, Jessica; Lefkove, Nehama; Gregg, Melanie; Hall, Craig; Easley, Kirk A.; Shenvi, Neeta; Wolf, Steven L.

    2012-01-01

    Mental imagery can improve motor performance in stroke populations when combined with physical therapy. Valid and reliable instruments to evaluate the imagery ability of stroke survivors are needed to maximize the benefits of mental imagery therapy. The purposes of this study were to: examine and compare the test-retest intra-rate reliability of the Movement Imagery Questionnaire-Revised, Second Edition (MIQ-RS) in stroke survivors and able-bodied controls, examine internal consistency of the visual and kinesthetic items of the MIQ-RS, determine if the MIQ-RS includes both the visual and kinesthetic dimensions of mental imagery, correlate impairment and motor imagery scores, and investigate the criterion validity of the MIQ-RS in stroke survivors by comparing the results to the KVIQ-10. Test-retest analysis indicated good levels of reliability (ICC range: .83–.99) and internal consistency (Cronbach α: .95–.98) of the visual and kinesthetic subscales in both groups. The two-factor structure of the MIQ-RS was supported by factor analysis, with the visual and kinesthetic components accounting for 88.6% and 83.4% of the total variance in the able-bodied and stroke groups, respectively. The MIQ-RS is a valid and reliable instrument in the stroke population examined and able-bodied populations and therefore useful as an outcome measure for motor imagery ability. PMID:22474504

  14. Factor validity and reliability of the aberrant behavior checklist-community (ABC-C) in an Indian population with intellectual disability.

    PubMed

    Lehotkay, R; Saraswathi Devi, T; Raju, M V R; Bada, P K; Nuti, S; Kempf, N; Carminati, G Galli

    2015-03-01

    In this study realised in collaboration with the department of psychology and parapsychology of Andhra University, validation of the Aberrant Behavior Checklist-Community (ABC-C) in Telugu, the official language of Andhra Pradesh, one of India's 28 states, was carried out. To assess the factor validity and reliability of this Telugu version, 120 participants with moderate to profound intellectual disability (94 men and 26 women, mean age 25.2, SD 7.1) were rated by the staff of the Lebenshilfe Institution for Mentally Handicapped in Visakhapatnam, Andhra Pradesh, India. Rating data were analysed with a confirmatory factor analysis. The internal consistency was estimated by Cronbach's alpha. To confirm the test-retest reliability, 50 participants were rated twice with an interval of 4 weeks, and 50 were rated by pairs of raters to assess inter-rater reliability. Confirmatory factor analysis revealed that the root mean square error of approximation (RMSEA) was equal to 0.06, the comparative fit index (CFI) was equal to 0.77, and the Tucker Lewis index (TLI) was equal to 0.77, which indicated that the model with five correlated factors had a good fit. Coefficient alpha ranged from 0.85 to 0.92 across the five subscales. Spearman's rank correlation coefficients for inter-rater reliability tests ranged from 0.65 to 0.75, and the correlations for test-retest reliability ranged from 0.58 to 0.76. All reliability coefficients were statistically significant (P < 0.01). The factor validity and reliability of Telugu version of the ABC-C evidenced factor validity and reliability comparable to the original English version and appears to be useful for assessing behaviour disorders in Indian people with intellectual disabilities. © 2014 MENCAP and International Association of the Scientific Study of Intellectual and Developmental Disabilities and John Wiley & Sons Ltd.

  15. Software reliability experiments data analysis and investigation

    NASA Technical Reports Server (NTRS)

    Walker, J. Leslie; Caglayan, Alper K.

    1991-01-01

    The objectives are to investigate the fundamental reasons which cause independently developed software programs to fail dependently, and to examine fault tolerant software structures which maximize reliability gain in the presence of such dependent failure behavior. The authors used 20 redundant programs from a software reliability experiment to analyze the software errors causing coincident failures, to compare the reliability of N-version and recovery block structures composed of these programs, and to examine the impact of diversity on software reliability using subpopulations of these programs. The results indicate that both conceptually related and unrelated errors can cause coincident failures and that recovery block structures offer more reliability gain than N-version structures if acceptance checks that fail independently from the software components are available. The authors present a theory of general program checkers that have potential application for acceptance tests.

  16. Intersession reliability of fMRI activation for heat pain and motor tasks

    PubMed Central

    Quiton, Raimi L.; Keaser, Michael L.; Zhuo, Jiachen; Gullapalli, Rao P.; Greenspan, Joel D.

    2014-01-01

    As the practice of conducting longitudinal fMRI studies to assess mechanisms of pain-reducing interventions becomes more common, there is a great need to assess the test–retest reliability of the pain-related BOLD fMRI signal across repeated sessions. This study quantitatively evaluated the reliability of heat pain-related BOLD fMRI brain responses in healthy volunteers across 3 sessions conducted on separate days using two measures: (1) intraclass correlation coefficients (ICC) calculated based on signal amplitude and (2) spatial overlap. The ICC analysis of pain-related BOLD fMRI responses showed fair-to-moderate intersession reliability in brain areas regarded as part of the cortical pain network. Areas with the highest intersession reliability based on the ICC analysis included the anterior midcingulate cortex, anterior insula, and second somatosensory cortex. Areas with the lowest intersession reliability based on the ICC analysis also showed low spatial reliability; these regions included pregenual anterior cingulate cortex, primary somatosensory cortex, and posterior insula. Thus, this study found regional differences in pain-related BOLD fMRI response reliability, which may provide useful information to guide longitudinal pain studies. A simple motor task (finger-thumb opposition) was performed by the same subjects in the same sessions as the painful heat stimuli were delivered. Intersession reliability of fMRI activation in cortical motor areas was comparable to previously published findings for both spatial overlap and ICC measures, providing support for the validity of the analytical approach used to assess intersession reliability of pain-related fMRI activation. A secondary finding of this study is that the use of standard ICC alone as a measure of reliability may not be sufficient, as the underlying variance structure of an fMRI dataset can result in inappropriately high ICC values; a method to eliminate these false positive results was used in this study and is recommended for future studies of test–retest reliability. PMID:25161897

  17. Efficient reliability analysis of structures with the rotational quasi-symmetric point- and the maximum entropy methods

    NASA Astrophysics Data System (ADS)

    Xu, Jun; Dang, Chao; Kong, Fan

    2017-10-01

    This paper presents a new method for efficient structural reliability analysis. In this method, a rotational quasi-symmetric point method (RQ-SPM) is proposed for evaluating the fractional moments of the performance function. Then, the derivation of the performance function's probability density function (PDF) is carried out based on the maximum entropy method in which constraints are specified in terms of fractional moments. In this regard, the probability of failure can be obtained by a simple integral over the performance function's PDF. Six examples, including a finite element-based reliability analysis and a dynamic system with strong nonlinearity, are used to illustrate the efficacy of the proposed method. All the computed results are compared with those by Monte Carlo simulation (MCS). It is found that the proposed method can provide very accurate results with low computational effort.

  18. Strength Analysis and Reliability Evaluation for Speed Reducers

    NASA Astrophysics Data System (ADS)

    Tsai, Yuo-Tern; Hsu, Yung-Yuan

    2017-09-01

    This paper studies the structural stresses of differential drive (DD) and harmonic drive (HD) for design improvement of reducers. The designed principles of the two reducers are reported for function comparison. The critical components of the reducers are constructed for performing motion simulation and stress analysis. DD is designed based on differential displacement of the decelerated gear ring as well as HD on a flexible spline. Finite element method (FEM) is used to analyze the structural stresses including the dynamic properties of the reducers. The stresses including kinematic properties of the two reducers are compared to observe the properties of the designs. The analyzed results are applied to identify the allowable loads of the reducers in use. The reliabilities of the reducers in different loads are further calculated according to the variation of stress. The studied results are useful on engineering analysis and reliability evaluation for designing a speed reducer with high ratios.

  19. Comparative analysis of design codes for timber bridges in Canada, the United States, and Europe

    Treesearch

    James Wacker; James (Scott) Groenier

    2010-01-01

    The United States recently completed its transition from the allowable stress design code to the load and resistance factor design (LRFD) reliability-based code for the design of most highway bridges. For an international perspective on the LRFD-based bridge codes, a comparative analysis is presented: a study addressed national codes of the United States, Canada, and...

  20. Quantifying frontal plane knee motion during single limb squats: reliability and validity of 2-dimensional measures.

    PubMed

    Gwynne, Craig R; Curran, Sarah A

    2014-12-01

    Clinical assessment of lower limb kinematics during dynamic tasks may identify individuals who demonstrate abnormal movement patterns that may lead to etiology of exacerbation of knee conditions such as patellofemoral joint (PFJt) pain. The purpose of this study was to determine the reliability, validity and associated measurement error of a clinically appropriate two-dimensional (2-D) procedure of quantifying frontal plane knee alignment during single limb squats. Nine female and nine male recreationally active subjects with no history of PFJt pain had frontal plane limb alignment assessed using three-dimensional (3-D) motion analysis and digital video cameras (2-D analysis) while performing single limb squats. The association between 2-D and 3-D measures was quantified using Pearson's product correlation coefficients. Intraclass correlation coefficients (ICCs) were determined for within- and between-session reliability of 2-D data and standard error of measurement (SEM) was used to establish measurement error. Frontal plane limb alignment assessed with 2-D analysis demonstrated good correlation compared with 3-D methods (r = 0.64 to 0.78, p < 0.001). Within-session (0.86) and between-session ICCs (0.74) demonstrated good reliability for 2-D measures and SEM scores ranged from 2° to 4°. 2-D measures have good consistency and may provide a valid measure of lower limb alignment when compared to existing 3-D methods. Assessment of lower limb kinematics using 2-D methods may be an accurate and clinically useful alternative to 3-D motion analysis when identifying individuals who demonstrate abnormal movement patterns associated with PFJt pain. 2b.

  1. Impact of nonrigid motion correction technique on pixel-wise pharmacokinetic analysis of free-breathing pulmonary dynamic contrast-enhanced MR imaging.

    PubMed

    Tokuda, Junichi; Mamata, Hatsuho; Gill, Ritu R; Hata, Nobuhiko; Kikinis, Ron; Padera, Robert F; Lenkinski, Robert E; Sugarbaker, David J; Hatabu, Hiroto

    2011-04-01

    To investigates the impact of nonrigid motion correction on pixel-wise pharmacokinetic analysis of free-breathing DCE-MRI in patients with solitary pulmonary nodules (SPNs). Misalignment of focal lesions due to respiratory motion in free-breathing dynamic contrast-enhanced MRI (DCE-MRI) precludes obtaining reliable time-intensity curves, which are crucial for pharmacokinetic analysis for tissue characterization. Single-slice 2D DCE-MRI was obtained in 15 patients. Misalignments of SPNs were corrected using nonrigid B-spline image registration. Pixel-wise pharmacokinetic parameters K(trans) , v(e) , and k(ep) were estimated from both original and motion-corrected DCE-MRI by fitting the two-compartment pharmacokinetic model to the time-intensity curve obtained in each pixel. The "goodness-of-fit" was tested with χ(2) -test in pixel-by-pixel basis to evaluate the reliability of the parameters. The percentages of reliable pixels within the SPNs were compared between the original and motion-corrected DCE-MRI. In addition, the parameters obtained from benign and malignant SPNs were compared. The percentage of reliable pixels in the motion-corrected DCE-MRI was significantly larger than the original DCE-MRI (P = 4 × 10(-7) ). Both K(trans) and k(ep) derived from the motion-corrected DCE-MRI showed significant differences between benign and malignant SPNs (P = 0.024, 0.015). The study demonstrated the impact of nonrigid motion correction technique on pixel-wise pharmacokinetic analysis of free-breathing DCE-MRI in SPNs. Copyright © 2011 Wiley-Liss, Inc.

  2. Statistical model selection for better prediction and discovering science mechanisms that affect reliability

    DOE PAGES

    Anderson-Cook, Christine M.; Morzinski, Jerome; Blecker, Kenneth D.

    2015-08-19

    Understanding the impact of production, environmental exposure and age characteristics on the reliability of a population is frequently based on underlying science and empirical assessment. When there is incomplete science to prescribe which inputs should be included in a model of reliability to predict future trends, statistical model/variable selection techniques can be leveraged on a stockpile or population of units to improve reliability predictions as well as suggest new mechanisms affecting reliability to explore. We describe a five-step process for exploring relationships between available summaries of age, usage and environmental exposure and reliability. The process involves first identifying potential candidatemore » inputs, then second organizing data for the analysis. Third, a variety of models with different combinations of the inputs are estimated, and fourth, flexible metrics are used to compare them. As a result, plots of the predicted relationships are examined to distill leading model contenders into a prioritized list for subject matter experts to understand and compare. The complexity of the model, quality of prediction and cost of future data collection are all factors to be considered by the subject matter experts when selecting a final model.« less

  3. The validity of transverse intermaxillary analysis by traditional PA cephalometry compared with cone-beam computed tomography.

    PubMed

    Cheung, Gordon; Goonewardene, Mithran Suresh; Islam, Syed Mohammed Shamsul; Murray, Kevin; Koong, Bernard

    2013-05-01

    To assess the validity of using jugale (J) and Antegonion (Ag) on Posterior-Anterior cephalograms (PAC) as landmarks for transverse intermaxillary analysis when compared with Cone Beam Computed Tomography (CBCT). Conventional PAC and CBCT images were taken of 28 dry skulls. Craniometric measurements between the bilateral landmarks, Antegonion and Jugale, were obtained from the skulls using a microscribe and recorded as the base standard. The corresponding andmarks were identified and measured on CBCT and PAC and compared with the base standard measurements. The accuracy and reliability of the measurements were statistically evaluated and the validity was assessed by comparing the ability of the two image modalities to accurately diagnose an arbitrarily selected J-J/Ag-Ag ratio. All measurements were repeated at least 7 weeks apart. Intra-class correlations (ICC) and Bland-Altman plots were used to analyse the data. All three methods were shown to be reliable as all had a mean error of less than 0.5 mm between repeated measurements. When compared with the base standard, CBCT measurements were shown to have higher agreement (ICC: 0.861-0.964) compared with measurements taken from PAC (ICC: 0.794-0.796). When the arbitrary J-J/Ag-Ag ratio was assessed, 18 per cent of cases were incorrectly diagnosed with a transverse discrepancy on the PAC compared with the CBCT which incorrectly diagnosed 8.7 per cent. CBCT was shown to be more reliable in assessing intermaxillary transverse discrepancy compared with PAC when using J-J/Ag-Ag ratios.

  4. Reliability based design of the primary structure of oil tankers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Casella, G.; Dogliani, M.; Guedes Soares, C.

    1996-12-31

    The present paper describes the reliability analysis carried out for two oil tanker-ships having comparable dimensions but different design. The scope of the analysis was to derive indications on the value of the reliability index obtained for existing, typical and well designed oil tankers, as well as to apply the tentative rule checking formulation developed within the CEC-funded SHIPREL Project. The checking formula was adopted to redesign the midships section of one of the considered ships, upgrading her in order to meet the target failure probability considered in the rule development process. The resulting structure, in view of an upgradingmore » of the steel grade in the central part of the deck, lead to a convenient reliability level. The results of the analysis clearly showed that a large scatter exists presently in the design safety levels of ships, even when the Classification Societies` unified requirements are satisfied. A reliability based approach for the calibration of the rules for the global strength of ships is therefore proposed, in order to assist designers and Classification Societies in the process of producing ships which are more optimized, with respect to ensured safety levels. Based on the work reported in the paper, the feasibility and usefulness of a reliability based approach in the development of ship longitudinal strength requirements has been demonstrated.« less

  5. Constellation Ground Systems Launch Availability Analysis: Enhancing Highly Reliable Launch Systems Design

    NASA Technical Reports Server (NTRS)

    Gernand, Jeffrey L.; Gillespie, Amanda M.; Monaghan, Mark W.; Cummings, Nicholas H.

    2010-01-01

    Success of the Constellation Program's lunar architecture requires successfully launching two vehicles, Ares I/Orion and Ares V/Altair, in a very limited time period. The reliability and maintainability of flight vehicles and ground systems must deliver a high probability of successfully launching the second vehicle in order to avoid wasting the on-orbit asset launched by the first vehicle. The Ground Operations Project determined which ground subsystems had the potential to affect the probability of the second launch and allocated quantitative availability requirements to these subsystems. The Ground Operations Project also developed a methodology to estimate subsystem reliability, availability and maintainability to ensure that ground subsystems complied with allocated launch availability and maintainability requirements. The verification analysis developed quantitative estimates of subsystem availability based on design documentation; testing results, and other information. Where appropriate, actual performance history was used for legacy subsystems or comparative components that will support Constellation. The results of the verification analysis will be used to verify compliance with requirements and to highlight design or performance shortcomings for further decision-making. This case study will discuss the subsystem requirements allocation process, describe the ground systems methodology for completing quantitative reliability, availability and maintainability analysis, and present findings and observation based on analysis leading to the Ground Systems Preliminary Design Review milestone.

  6. Reliability based design optimization: Formulations and methodologies

    NASA Astrophysics Data System (ADS)

    Agarwal, Harish

    Modern products ranging from simple components to complex systems should be designed to be optimal and reliable. The challenge of modern engineering is to ensure that manufacturing costs are reduced and design cycle times are minimized while achieving requirements for performance and reliability. If the market for the product is competitive, improved quality and reliability can generate very strong competitive advantages. Simulation based design plays an important role in designing almost any kind of automotive, aerospace, and consumer products under these competitive conditions. Single discipline simulations used for analysis are being coupled together to create complex coupled simulation tools. This investigation focuses on the development of efficient and robust methodologies for reliability based design optimization in a simulation based design environment. Original contributions of this research are the development of a novel efficient and robust unilevel methodology for reliability based design optimization, the development of an innovative decoupled reliability based design optimization methodology, the application of homotopy techniques in unilevel reliability based design optimization methodology, and the development of a new framework for reliability based design optimization under epistemic uncertainty. The unilevel methodology for reliability based design optimization is shown to be mathematically equivalent to the traditional nested formulation. Numerical test problems show that the unilevel methodology can reduce computational cost by at least 50% as compared to the nested approach. The decoupled reliability based design optimization methodology is an approximate technique to obtain consistent reliable designs at lesser computational expense. Test problems show that the methodology is computationally efficient compared to the nested approach. A framework for performing reliability based design optimization under epistemic uncertainty is also developed. A trust region managed sequential approximate optimization methodology is employed for this purpose. Results from numerical test studies indicate that the methodology can be used for performing design optimization under severe uncertainty.

  7. [Reliability and validity of the Braden Scale for predicting pressure sore risk].

    PubMed

    Boes, C

    2000-12-01

    For more accurate and objective pressure sore risk assessment various risk assessment tools were developed mainly in the USA and Great Britain. The Braden Scale for Predicting Pressure Sore Risk is one such example. By means of a literature analysis of German and English texts referring to the Braden Scale the scientific control criteria reliability and validity will be traced and consequences for application of the scale in Germany will be demonstrated. Analysis of 4 reliability studies shows an exclusive focus on interrater reliability. Further, even though examination of 19 validity studies occurs in many different settings, such examination is limited to the criteria sensitivity and specificity (accuracy). The range of sensitivity and specificity level is 35-100%. The recommended cut off points rank in the field of 10 to 19 points. The studies prove to be not comparable with each other. Furthermore, distortions in these studies can be found which affect accuracy of the scale. The results of the here presented analysis show an insufficient proof for reliability and validity in the American studies. In Germany, the Braden scale has not yet been tested under scientific criteria. Such testing is needed before using the scale in different German settings. During the course of such testing, construction and study procedures of the American studies can be used as a basis as can the problems be identified in the analysis presented below.

  8. Reliability Analysis of a Green Roof Under Different Storm Scenarios

    NASA Astrophysics Data System (ADS)

    William, R. K.; Stillwell, A. S.

    2015-12-01

    Urban environments continue to face the challenges of localized flooding and decreased water quality brought on by the increasing amount of impervious area in the built environment. Green infrastructure provides an alternative to conventional storm sewer design by using natural processes to filter and store stormwater at its source. However, there are currently few consistent standards available in North America to ensure that installed green infrastructure is performing as expected. This analysis offers a method for characterizing green roof failure using a visual aid commonly used in earthquake engineering: fragility curves. We adapted the concept of the fragility curve based on the efficiency in runoff reduction provided by a green roof compared to a conventional roof under different storm scenarios. We then used the 2D distributed surface water-groundwater coupled model MIKE SHE to model the impact that a real green roof might have on runoff in different storm events. We then employed a multiple regression analysis to generate an algebraic demand model that was input into the Matlab-based reliability analysis model FERUM, which was then used to calculate the probability of failure. The use of reliability analysis as a part of green infrastructure design code can provide insights into green roof weaknesses and areas for improvement. It also supports the design of code that is more resilient than current standards and is easily testable for failure. Finally, the understanding of reliability of a single green roof module under different scenarios can support holistic testing of system reliability.

  9. Reliability analysis of composite laminates with load sharing

    NASA Technical Reports Server (NTRS)

    Wetherhold, Robert C.; Thomas, David J.

    1991-01-01

    By viewing a composite lamina as a homogeneous solid whose directional strengths are random variables, lamina reliability under multiaxial stresses may be determined using either an interactive or a noninteractive criterion. From the reliability values for the individual laminae comprising a given laminate, Thomas and Wetherhold (1991) have proposed a method for determining bounds for the overall laminate reliability. In this paper, simple physically plausible phenomenological rules are proposed for redistribution of load after a lamina has failed within the confines of a laminate. These rules are illustrated by application to (0/ +/-15)s and (90/ +/-45/0)s graphite/epoxy laminates, and the results are compared to the previously proposed bounds.

  10. A simulation model for risk assessment of turbine wheels

    NASA Technical Reports Server (NTRS)

    Safie, Fayssal M.; Hage, Richard T.

    1991-01-01

    A simulation model has been successfully developed to evaluate the risk of the Space Shuttle auxiliary power unit (APU) turbine wheels for a specific inspection policy. Besides being an effective tool for risk/reliability evaluation, the simulation model also allows the analyst to study the trade-offs between wheel reliability, wheel life, inspection interval, and rejection crack size. For example, in the APU application, sensitivity analysis results showed that the wheel life limit has the least effect on wheel reliability when compared to the effect of the inspection interval and the rejection crack size. In summary, the simulation model developed represents a flexible tool to predict turbine wheel reliability and study the risk under different inspection policies.

  11. A simulation model for risk assessment of turbine wheels

    NASA Astrophysics Data System (ADS)

    Safie, Fayssal M.; Hage, Richard T.

    A simulation model has been successfully developed to evaluate the risk of the Space Shuttle auxiliary power unit (APU) turbine wheels for a specific inspection policy. Besides being an effective tool for risk/reliability evaluation, the simulation model also allows the analyst to study the trade-offs between wheel reliability, wheel life, inspection interval, and rejection crack size. For example, in the APU application, sensitivity analysis results showed that the wheel life limit has the least effect on wheel reliability when compared to the effect of the inspection interval and the rejection crack size. In summary, the simulation model developed represents a flexible tool to predict turbine wheel reliability and study the risk under different inspection policies.

  12. Comparison between three option, four option and five option multiple choice question tests for quality parameters: A randomized study.

    PubMed

    Vegada, Bhavisha; Shukla, Apexa; Khilnani, Ajeetkumar; Charan, Jaykaran; Desai, Chetna

    2016-01-01

    Most of the academic teachers use four or five options per item of multiple choice question (MCQ) test as formative and summative assessment. Optimal number of options in MCQ item is a matter of considerable debate among academic teachers of various educational fields. There is a scarcity of the published literature regarding the optimum number of option in each item of MCQ in the field of medical education. To compare three options, four options, and five options MCQs test for the quality parameters - reliability, validity, item analysis, distracter analysis, and time analysis. Participants were 3 rd semester M.B.B.S. students. Students were divided randomly into three groups. Each group was given one set of MCQ test out of three options, four options, and five option randomly. Following the marking of the multiple choice tests, the participants' option selections were analyzed and comparisons were conducted of the mean marks, mean time, validity, reliability and facility value, discrimination index, point biserial value, distracter analysis of three different option formats. Students score more ( P = 0.000) and took less time ( P = 0.009) for the completion of three options as compared to four options and five options groups. Facility value was more ( P = 0.004) in three options group as compared to four and five options groups. There was no significant difference between three groups for the validity, reliability, and item discrimination. Nonfunctioning distracters were more in the four and five options group as compared to three option group. Assessment based on three option MCQs is can be preferred over four option and five option MCQs.

  13. A systematic review of statistical methods used to test for reliability of medical instruments measuring continuous variables.

    PubMed

    Zaki, Rafdzah; Bulgiba, Awang; Nordin, Noorhaire; Azina Ismail, Noor

    2013-06-01

    Reliability measures precision or the extent to which test results can be replicated. This is the first ever systematic review to identify statistical methods used to measure reliability of equipment measuring continuous variables. This studyalso aims to highlight the inappropriate statistical method used in the reliability analysis and its implication in the medical practice. In 2010, five electronic databases were searched between 2007 and 2009 to look for reliability studies. A total of 5,795 titles were initially identified. Only 282 titles were potentially related, and finally 42 fitted the inclusion criteria. The Intra-class Correlation Coefficient (ICC) is the most popular method with 25 (60%) studies having used this method followed by the comparing means (8 or 19%). Out of 25 studies using the ICC, only 7 (28%) reported the confidence intervals and types of ICC used. Most studies (71%) also tested the agreement of instruments. This study finds that the Intra-class Correlation Coefficient is the most popular method used to assess the reliability of medical instruments measuring continuous outcomes. There are also inappropriate applications and interpretations of statistical methods in some studies. It is important for medical researchers to be aware of this issue, and be able to correctly perform analysis in reliability studies.

  14. Systematic review of methods for quantifying teamwork in the operating theatre

    PubMed Central

    Marshall, D.; Sykes, M.; McCulloch, P.; Shalhoub, J.; Maruthappu, M.

    2018-01-01

    Background Teamwork in the operating theatre is becoming increasingly recognized as a major factor in clinical outcomes. Many tools have been developed to measure teamwork. Most fall into two categories: self‐assessment by theatre staff and assessment by observers. A critical and comparative analysis of the validity and reliability of these tools is lacking. Methods MEDLINE and Embase databases were searched following PRISMA guidelines. Content validity was assessed using measurements of inter‐rater agreement, predictive validity and multisite reliability, and interobserver reliability using statistical measures of inter‐rater agreement and reliability. Quantitative meta‐analysis was deemed unsuitable. Results Forty‐eight articles were selected for final inclusion; self‐assessment tools were used in 18 and observational tools in 28, and there were two qualitative studies. Self‐assessment of teamwork by profession varied with the profession of the assessor. The most robust self‐assessment tool was the Safety Attitudes Questionnaire (SAQ), although this failed to demonstrate multisite reliability. The most robust observational tool was the Non‐Technical Skills (NOTECHS) system, which demonstrated both test–retest reliability (P > 0·09) and interobserver reliability (Rwg = 0·96). Conclusion Self‐assessment of teamwork by the theatre team was influenced by professional differences. Observational tools, when used by trained observers, circumvented this.

  15. Assessment of family functioning in Caucasian and Hispanic Americans: reliability, validity, and factor structure of the Family Assessment Device.

    PubMed

    Aarons, Gregory A; McDonald, Elizabeth J; Connelly, Cynthia D; Newton, Rae R

    2007-12-01

    The purpose of this study was to examine the factor structure, reliability, and validity of the Family Assessment Device (FAD) among a national sample of Caucasian and Hispanic American families receiving public sector mental health services. A confirmatory factor analysis conducted to test model fit yielded equivocal findings. With few exceptions, indices of model fit, reliability, and validity were poorer for Hispanic Americans compared with Caucasian Americans. Contrary to our expectation, an exploratory factor analysis did not result in a better fitting model of family functioning. Without stronger evidence supporting a reformulation of the FAD, we recommend against such a course of action. Findings highlight the need for additional research on the role of culture in measurement of family functioning.

  16. Superior model for fault tolerance computation in designing nano-sized circuit systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Singh, N. S. S., E-mail: narinderjit@petronas.com.my; Muthuvalu, M. S., E-mail: msmuthuvalu@gmail.com; Asirvadam, V. S., E-mail: vijanth-sagayan@petronas.com.my

    2014-10-24

    As CMOS technology scales nano-metrically, reliability turns out to be a decisive subject in the design methodology of nano-sized circuit systems. As a result, several computational approaches have been developed to compute and evaluate reliability of desired nano-electronic circuits. The process of computing reliability becomes very troublesome and time consuming as the computational complexity build ups with the desired circuit size. Therefore, being able to measure reliability instantly and superiorly is fast becoming necessary in designing modern logic integrated circuits. For this purpose, the paper firstly looks into the development of an automated reliability evaluation tool based on the generalizationmore » of Probabilistic Gate Model (PGM) and Boolean Difference-based Error Calculator (BDEC) models. The Matlab-based tool allows users to significantly speed-up the task of reliability analysis for very large number of nano-electronic circuits. Secondly, by using the developed automated tool, the paper explores into a comparative study involving reliability computation and evaluation by PGM and, BDEC models for different implementations of same functionality circuits. Based on the reliability analysis, BDEC gives exact and transparent reliability measures, but as the complexity of the same functionality circuits with respect to gate error increases, reliability measure by BDEC tends to be lower than the reliability measure by PGM. The lesser reliability measure by BDEC is well explained in this paper using distribution of different signal input patterns overtime for same functionality circuits. Simulation results conclude that the reliability measure by BDEC depends not only on faulty gates but it also depends on circuit topology, probability of input signals being one or zero and also probability of error on signal lines.« less

  17. Clinical methods to quantify trunk mobility in an elite male surfing population.

    PubMed

    Furness, James; Climstein, Mike; Sheppard, Jeremy M; Abbott, Allan; Hing, Wayne

    2016-05-01

    Thoracic mobility in the sagittal and horizontal planes are key requirements in the sport of surfing; however to date the normal values of these movements have not yet been quantified in a surfing population. To develop a reliable method to quantify thoracic mobility in the sagittal plane; to assess the reliability of an existing thoracic rotation method, and quantify thoracic mobility in an elite male surfing population. Clinical Measurement, reliability and comparative study. A total of 30 subjects were used to determine the reliability component. 15 elite surfers were used as part of a comparative analysis with age and gender matched controls. Intraclass correlation coefficient values ranged between 0.95-0.99 (95% CI; 0.89-0.99) for both thoracic methods. The elite surfing group had significantly (p ≤ 0.05) greater rotation than the comparative group (mean rotation 63.57° versus 40.80°, respectively). This study has illustrated reliable methods to assess the thoracic spine in the sagittal plane and thoracic rotation. It has also quantified ROM in a surfing cohort; identifying thoracic rotation as a key movement. This information may provide clinicians, coaches and athletic trainers with imperative information regarding the importance of maintaining adequate thoracic rotation. Copyright © 2015 Elsevier Ltd. All rights reserved.

  18. Application of SAW method for multiple-criteria comparative analysis of the reliability of heat supply organizations

    NASA Astrophysics Data System (ADS)

    Akhmetova, I. G.; Chichirova, N. D.

    2016-12-01

    Heat supply is the most energy-consuming sector of the economy. Approximately 30% of all used primary fuel-and-energy resources is spent on municipal heat-supply needs. One of the key indicators of activity of heat-supply organizations is the reliability of an energy facility. The reliability index of a heat supply organization is of interest to potential investors for assessing risks when investing in projects. The reliability indices established by the federal legislation are actually reduced to a single numerical factor, which depends on the number of heat-supply outages in connection with disturbances in operation of heat networks and the volume of their resource recovery in the calculation year. This factor is rather subjective and may change in a wide range during several years. A technique is proposed for evaluating the reliability of heat-supply organizations with the use of the simple additive weighting (SAW) method. The technique for integrated-index determination satisfies the following conditions: the reliability level of the evaluated heat-supply system is represented maximum fully and objectively; the information used for the reliability-index evaluation is easily available (is located on the Internet in accordance with demands of data-disclosure standards). For reliability estimation of heat-supply organizations, the following indicators were selected: the wear of equipment of thermal energy sources, the wear of heat networks, the number of outages of supply of thermal energy (heat carrier due to technological disturbances on heat networks per 1 km of heat networks), the number of outages of supply of thermal energy (heat carrier due to technologic disturbances on thermal energy sources per 1 Gcal/h of installed power), the share of expenditures in the cost of thermal energy aimed at recovery of the resource (renewal of fixed assets), coefficient of renewal of fixed assets, and a coefficient of fixed asset retirement. A versatile program is developed and the analysis of heat-supply organizations is performed by the example of the Republic of Tatarstan. The assessment system is based on construction of comparative ratings of heat-supply organizations. A rating is the assessment of reliability of the organization, is characterized by a numerical value, and makes it possible to compare organizations engaged in the same kind of activity between each other.

  19. Is intra-bladder pressure measurement a reliable indicator for raised intra-abdominal pressure? A prospective comparative study.

    PubMed

    Al-Abassi, Abdulla Ahmed; Al Saadi, Azan Saleh; Ahmed, Faisal

    2018-06-19

    Intra-abdominal pressure (IAP) can be measured by several indirect methods; however, the urinary bladder is largely preferred. The aim of this study was to compare intra-bladder pressure (IBP) at different levels of IAPs and assess its reliability as an indirect method for IAP measurement. We compared IBP with IAP in twenty-one patients undergoing laparoscopic cholecystectomy under general anesthesia. Measurements were recorded at increasing levels of insufflation pressures to approximately 22 mmHg. Pearson's correlation coefficient was calculated to establish the relationship between the two pressure measurements and Bland-Altman analysis was used to assess the limits of agreement between the two methods of measurements. The urinary bladder pressures reflected well the pressures in the abdominal cavity. Pearson correlation coefficient showed a good correlation between the two measurement techniques (r = 0.966, p < 0.0001) and Bland-Altman analysis indicated that the 95% limits of agreement between the two methods ranged from - 2.83 to 2.64. This range is accepted both clinically and according to the recommendations of the World Society of Abdominal Compartment Syndrome (WSACS). Our study showed that IBP measurement is a simple, minimally invasive method that may reliably estimates IAP in patients placed in supine position. Measurements for pressures higher than 12 mmHg may be less reliable. When applied clinically, this should alert the clinician to take safety measures to avoid abdominal compartment syndrome (ACS).

  20. Validation of Observations Obtained with a Liquid Mirror Telescope by Comparison with Sloan Digital Sky Survey Observations

    NASA Astrophysics Data System (ADS)

    Borra, E. F.

    2015-06-01

    The results of a search for peculiar astronomical objects using very low resolution spectra obtained with the NASA Orbital Debris Observatory (NODO) 3 m diameter liquid mirror telescope (LMT) are compared with results of spectra obtained with the Sloan Digital Sky Survey (SDSS). The main purpose of this comparison is to verify whether observations taken with this novel type of telescope are reliable. This comparison is important because LMTs are an inexpensive novel type of telescope that is very useful for astronomical surveys, particularly surveys in the time domain, and validation of the data taken with an LMT by comparison with data from a classical telescope will validate their reliability. We start from a published data analysis that classified as peculiar only 206 of the 18,000 astronomical objects observed with the NODO LMT. A total of 29 of these 206 objects were found in the SDSS. The reliability of the NODO data can be seen through the results of the detailed analysis that, in practice, incorrectly identified less than 0.3% of the 18,000 spectra as peculiar objects, most likely because they are variable stars. We conclude that the LMT gave reliable observations, comparable to those that would have been obtained with a telescope using a glass mirror.

  1. Inter-method reliability of paper surveys and computer assisted telephone interviews in a randomized controlled trial of yoga for low back pain

    PubMed Central

    2014-01-01

    Background Little is known about the reliability of different methods of survey administration in low back pain trials. This analysis was designed to determine the reliability of responses to self-administered paper surveys compared to computer assisted telephone interviews (CATI) for the primary outcomes of pain intensity and back-related function, and secondary outcomes of patient satisfaction, SF-36, and global improvement among participants enrolled in a study of yoga for chronic low back pain. Results Pain intensity, back-related function, and both physical and mental health components of the SF-36 showed excellent reliability at all three time points; ICC scores ranged from 0.82 to 0.98. Pain medication use showed good reliability; kappa statistics ranged from 0.68 to 0.78. Patient satisfaction had moderate to excellent reliability; ICC scores ranged from 0.40 to 0.86. Global improvement showed poor reliability at 6 weeks (ICC = 0.24) and 12 weeks (ICC = 0.10). Conclusion CATI shows excellent reliability for primary outcomes and at least some secondary outcomes when compared to self-administered paper surveys in a low back pain yoga trial. Having two reliable options for data collection may be helpful to increase response rates for core outcomes in back pain trials. Trial registration ClinicalTrials.gov: NCT01761617. Date of trial registration: December 4, 2012. PMID:24716775

  2. Reliability of Various Measurement Stations for Determining Plantar Fascia Thickness and Echogenicity.

    PubMed

    Bisi-Balogun, Adebisi; Cassel, Michael; Mayer, Frank

    2016-04-13

    This study aimed to determine the relative and absolute reliability of ultrasound (US) measurements of the thickness and echogenicity of the plantar fascia (PF) at different measurement stations along its length using a standardized protocol. Twelve healthy subjects (24 feet) were enrolled. The PF was imaged in the longitudinal plane. Subjects were assessed twice to evaluate the intra-rater reliability. A quantitative evaluation of the thickness and echogenicity of the plantar fascia was performed using Image J, a digital image analysis and viewer software. A sonography evaluation of the thickness and echogenicity of the PF showed a high relative reliability with an Intra class correlation coefficient of ≥0.88 at all measurement stations. However, the measurement stations for both the PF thickness and echogenicity which showed the highest intraclass correlation coefficient (ICCs) did not have the highest absolute reliability. Compared to other measurement stations, measuring the PF thickness at 3 cm distal and the echogenicity at a region of interest 1 cm to 2 cm distal from its insertion at the medial calcaneal tubercle showed the highest absolute reliability with the least systematic bias and random error. Also, the reliability was higher using a mean of three measurements compared to one measurement. To reduce discrepancies in the interpretation of the thickness and echogenicity measurements of the PF, the absolute reliability of the different measurement stations should be considered in clinical practice and research rather than the relative reliability with the ICC.

  3. Reliability of Various Measurement Stations for Determining Plantar Fascia Thickness and Echogenicity

    PubMed Central

    Bisi-Balogun, Adebisi; Cassel, Michael; Mayer, Frank

    2016-01-01

    This study aimed to determine the relative and absolute reliability of ultrasound (US) measurements of the thickness and echogenicity of the plantar fascia (PF) at different measurement stations along its length using a standardized protocol. Twelve healthy subjects (24 feet) were enrolled. The PF was imaged in the longitudinal plane. Subjects were assessed twice to evaluate the intra-rater reliability. A quantitative evaluation of the thickness and echogenicity of the plantar fascia was performed using Image J, a digital image analysis and viewer software. A sonography evaluation of the thickness and echogenicity of the PF showed a high relative reliability with an Intra class correlation coefficient of ≥0.88 at all measurement stations. However, the measurement stations for both the PF thickness and echogenicity which showed the highest intraclass correlation coefficient (ICCs) did not have the highest absolute reliability. Compared to other measurement stations, measuring the PF thickness at 3 cm distal and the echogenicity at a region of interest 1 cm to 2 cm distal from its insertion at the medial calcaneal tubercle showed the highest absolute reliability with the least systematic bias and random error. Also, the reliability was higher using a mean of three measurements compared to one measurement. To reduce discrepancies in the interpretation of the thickness and echogenicity measurements of the PF, the absolute reliability of the different measurement stations should be considered in clinical practice and research rather than the relative reliability with the ICC. PMID:27089369

  4. Reliability analysis of a robotic system using hybridized technique

    NASA Astrophysics Data System (ADS)

    Kumar, Naveen; Komal; Lather, J. S.

    2017-09-01

    In this manuscript, the reliability of a robotic system has been analyzed using the available data (containing vagueness, uncertainty, etc). Quantification of involved uncertainties is done through data fuzzification using triangular fuzzy numbers with known spreads as suggested by system experts. With fuzzified data, if the existing fuzzy lambda-tau (FLT) technique is employed, then the computed reliability parameters have wide range of predictions. Therefore, decision-maker cannot suggest any specific and influential managerial strategy to prevent unexpected failures and consequently to improve complex system performance. To overcome this problem, the present study utilizes a hybridized technique. With this technique, fuzzy set theory is utilized to quantify uncertainties, fault tree is utilized for the system modeling, lambda-tau method is utilized to formulate mathematical expressions for failure/repair rates of the system, and genetic algorithm is utilized to solve established nonlinear programming problem. Different reliability parameters of a robotic system are computed and the results are compared with the existing technique. The components of the robotic system follow exponential distribution, i.e., constant. Sensitivity analysis is also performed and impact on system mean time between failures (MTBF) is addressed by varying other reliability parameters. Based on analysis some influential suggestions are given to improve the system performance.

  5. A comparative reliability analysis of free-piston Stirling machines

    NASA Astrophysics Data System (ADS)

    Schreiber, Jeffrey G.

    2001-02-01

    A free-piston Stirling power convertor is being developed for use in an advanced radioisotope power system to provide electric power for NASA deep space missions. These missions are typically long lived, lasting for up to 14 years. The Department of Energy (DOE) is responsible for providing the radioisotope power system for the NASA missions, and has managed the development of the free-piston power convertor for this application. The NASA Glenn Research Center has been involved in the development of Stirling power conversion technology for over 25 years and is currently providing support to DOE. Due to the nature of the potential missions, long life and high reliability are important features for the power system. Substantial resources have been spent on the development of long life Stirling cryocoolers for space applications. As a very general statement, free-piston Stirling power convertors have many features in common with free-piston Stirling cryocoolers, however there are also significant differences. For example, designs exist for both power convertors and cryocoolers that use the flexure bearing support system to provide noncontacting operation of the close-clearance moving parts. This technology and the operating experience derived from one application may be readily applied to the other application. This similarity does not pertain in the case of outgassing and contamination. In the cryocooler, the contaminants normally condense in the critical heat exchangers and foul the performance. In the Stirling power convertor just the opposite is true as contaminants condense on non-critical surfaces. A methodology was recently published that provides a relative comparison of reliability, and is applicable to systems. The methodology has been applied to compare the reliability of a Stirling cryocooler relative to that of a free-piston Stirling power convertor. The reliability analysis indicates that the power convertor should be able to have superior reliability compared to the cryocooler. .

  6. A Monte Carlo Simulation Study of the Reliability of Intraindividual Variability

    PubMed Central

    Estabrook, Ryne; Grimm, Kevin J.; Bowles, Ryan P.

    2012-01-01

    Recent research has seen intraindividual variability (IIV) become a useful technique to incorporate trial-to-trial variability into many types of psychological studies. IIV as measured by individual standard deviations (ISDs) has shown unique prediction to several types of positive and negative outcomes (Ram, Rabbit, Stollery, & Nesselroade, 2005). One unanswered question regarding measuring intraindividual variability is its reliability and the conditions under which optimal reliability is achieved. Monte Carlo simulation studies were conducted to determine the reliability of the ISD compared to the intraindividual mean. The results indicate that ISDs generally have poor reliability and are sensitive to insufficient measurement occasions, poor test reliability, and unfavorable amounts and distributions of variability in the population. Secondary analysis of psychological data shows that use of individual standard deviations in unfavorable conditions leads to a marked reduction in statistical power, although careful adherence to underlying statistical assumptions allows their use as a basic research tool. PMID:22268793

  7. Rasch analysis and impact factor methods both yield valid and comparable measures of health status in interstitial lung disease.

    PubMed

    Patel, Amit S; Siegert, Richard J; Bajwah, Sabrina; Brignall, Kate; Gosker, Harry R; Moxham, John; Maher, Toby M; Renzoni, Elisabetta A; Wells, Athol U; Higginson, Irene J; Birring, Surinder S

    2015-09-01

    Rasch analysis has largely replaced impact factor methodology for developing health status measures. The aim of this study was to develop a health status questionnaire for patients with interstitial lung disease (ILD) using impact factor methodology and to compare its validity with that of another version developed using Rasch analysis. A preliminary 71-item questionnaire was developed and evaluated in 173 patients with ILD. Items were reduced by the impact factor method (King's Brief ILD questionnaire, KBILD-I) and Rasch analysis (KBILD-R). Both questionnaires were validated by assessing their relationship with forced vital capacity (FVC) and St Georges Respiratory Questionnaire (SGRQ) and by evaluating internal reliability, repeatability, and longitudinal responsiveness. The KBILD-R and KBILD-I comprised 15 items each. The content of eight items differed between the KBILD-R and KBILD-I. Internal and test-retest reliability was good for total scores of both questionnaires. There was a good relationship with SGRQ and moderate relationship with FVC for both questionnaires. Effect sizes were comparable. Both questionnaires discriminated patients with differing disease severity. Despite considerable differences in the content of retained items, both KBILD-R and KBILD-I questionnaires demonstrated acceptable measurement properties and performed comparably in a clinical setting. Copyright © 2015 Elsevier Inc. All rights reserved.

  8. Correlation and Reliability of Cervical Sagittal Alignment Parameters between Lateral Cervical Radiograph and Lateral Whole-Body EOS Stereoradiograph.

    PubMed

    Singhatanadgige, Weerasak; Kang, Daniel G; Luksanapruksa, Panya; Peters, Colleen; Riew, K Daniel

    2016-09-01

    Retrospective analysis. To evaluate the correlation and reliability of cervical sagittal alignment parameters obtained from lateral cervical radiographs (XRs) compared with lateral whole-body stereoradiographs (SRs). We evaluated adults with cervical deformity using both lateral XRs and lateral SRs obtained within 1 week of each other between 2010 and 2014. XR and SR images were measured by two independent spine surgeons using the following sagittal alignment parameters: C2-C7 sagittal Cobb angle (SCA), C2-C7 sagittal vertical axis (SVA), C1-C7 translational distance (C1-7), T1 slope (T1-S), neck tilt (NT), and thoracic inlet angle (TIA). Pearson correlation and paired t test were used for statistical analysis, with intra- and interrater reliability analyzed using intraclass correlation coefficient (ICC). A total of 35 patients were included in the study. We found excellent intrarater reliability for all sagittal alignment parameters in both the XR and SR groups with ICC ranging from 0.799 to 0.994 for XR and 0.791 to 0.995 for SR. Interrater reliability was also excellent for all parameters except NT and TIA, which had fair reliability. We also found excellent correlations between XR and SR measurements for most sagittal alignment parameters; SCA, SVA, and C1-C7 had r > 0.90, and only NT had r < 0.70. There was a significant difference between groups, with SR having lower measurements compared with XR for both SVA (0.68 cm lower, p < 0.001) and C1-C7 (1.02 cm lower, p < 0.001). There were no differences between groups for SCA, T1-S, NT, and TIA. Whole-body stereoradiography appears to be a viable alternative for measuring cervical sagittal alignment parameters compared with standard radiography. XR and SR demonstrated excellent correlation for most sagittal alignment parameters except NT. However, SR had significantly lower average SVA and C1-C7 measurements than XR. The lower radiation exposure using single SR has to be weighed against its higher cost compared with XR.

  9. Benchmark analysis of forecasted seasonal temperature over different climatic areas

    NASA Astrophysics Data System (ADS)

    Giunta, G.; Salerno, R.; Ceppi, A.; Ercolani, G.; Mancini, M.

    2015-12-01

    From a long-term perspective, an improvement of seasonal forecasting, which is often exclusively based on climatology, could provide a new capability for the management of energy resources in a time scale of just a few months. This paper regards a benchmark analysis in relation to long-term temperature forecasts over Italy in the year 2010, comparing the eni-kassandra meteo forecast (e-kmf®) model, the Climate Forecast System-National Centers for Environmental Prediction (CFS-NCEP) model, and the climatological reference (based on 25-year data) with observations. Statistical indexes are used to understand the reliability of the prediction of 2-m monthly air temperatures with a perspective of 12 weeks ahead. The results show how the best performance is achieved by the e-kmf® system which improves the reliability for long-term forecasts compared to climatology and the CFS-NCEP model. By using the reliable high-performance forecast system, it is possible to optimize the natural gas portfolio and management operations, thereby obtaining a competitive advantage in the European energy market.

  10. Metrological Reliability of Medical Devices

    NASA Astrophysics Data System (ADS)

    Costa Monteiro, E.; Leon, L. F.

    2015-02-01

    The prominent development of health technologies of the 20th century triggered demands for metrological reliability of physiological measurements comprising physical, chemical and biological quantities, essential to ensure accurate and comparable results of clinical measurements. In the present work, aspects concerning metrological reliability in premarket and postmarket assessments of medical devices are discussed, pointing out challenges to be overcome. In addition, considering the social relevance of the biomeasurements results, Biometrological Principles to be pursued by research and innovation aimed at biomedical applications are proposed, along with the analysis of their contributions to guarantee the innovative health technologies compliance with the main ethical pillars of Bioethics.

  11. Reliability and criterion validity of measurements using a smart phone-based measurement tool for the transverse rotation angle of the pelvis during single-leg lifting.

    PubMed

    Jung, Sung-Hoon; Kwon, Oh-Yun; Jeon, In-Cheol; Hwang, Ui-Jae; Weon, Jong-Hyuck

    2018-01-01

    The purposes of this study were to determine the intra-rater test-retest reliability of a smart phone-based measurement tool (SBMT) and a three-dimensional (3D) motion analysis system for measuring the transverse rotation angle of the pelvis during single-leg lifting (SLL) and the criterion validity of the transverse rotation angle of the pelvis measurement using SBMT compared with a 3D motion analysis system (3DMAS). Seventeen healthy volunteers performed SLL with their dominant leg without bending the knee until they reached a target placed 20 cm above the table. This study used a 3DMAS, considered the gold standard, to measure the transverse rotation angle of the pelvis to assess the criterion validity of the SBMT measurement. Intra-rater test-retest reliability was determined using the SBMT and 3DMAS using intra-class correlation coefficient (ICC) [3,1] values. The criterion validity of the SBMT was assessed with ICC [3,1] values. Both the 3DMAS (ICC = 0.77) and SBMT (ICC = 0.83) showed excellent intra-rater test-retest reliability in the measurement of the transverse rotation angle of the pelvis during SLL in a supine position. Moreover, the SBMT showed an excellent correlation with the 3DMAS (ICC = 0.99). Measurement of the transverse rotation angle of the pelvis using the SBMT showed excellent reliability and criterion validity compared with the 3DMAS.

  12. Electric propulsion reliability: Statistical analysis of on-orbit anomalies and comparative analysis of electric versus chemical propulsion failure rates

    NASA Astrophysics Data System (ADS)

    Saleh, Joseph Homer; Geng, Fan; Ku, Michelle; Walker, Mitchell L. R.

    2017-10-01

    With a few hundred spacecraft launched to date with electric propulsion (EP), it is possible to conduct an epidemiological study of EP's on orbit reliability. The first objective of the present work was to undertake such a study and analyze EP's track record of on orbit anomalies and failures by different covariates. The second objective was to provide a comparative analysis of EP's failure rates with those of chemical propulsion. Satellite operators, manufacturers, and insurers will make reliability- and risk-informed decisions regarding the adoption and promotion of EP on board spacecraft. This work provides evidence-based support for such decisions. After a thorough data collection, 162 EP-equipped satellites launched between January 1997 and December 2015 were included in our dataset for analysis. Several statistical analyses were conducted, at the aggregate level and then with the data stratified by severity of the anomaly, by orbit type, and by EP technology. Mean Time To Anomaly (MTTA) and the distribution of the time to (minor/major) anomaly were investigated, as well as anomaly rates. The important findings in this work include the following: (1) Post-2005, EP's reliability has outperformed that of chemical propulsion; (2) Hall thrusters have robustly outperformed chemical propulsion, and they maintain a small but shrinking reliability advantage over gridded ion engines. Other results were also provided, for example the differentials in MTTA of minor and major anomalies for gridded ion engines and Hall thrusters. It was shown that: (3) Hall thrusters exhibit minor anomalies very early on orbit, which might be indicative of infant anomalies, and thus would benefit from better ground testing and acceptance procedures; (4) Strong evidence exists that EP anomalies (onset and likelihood) and orbit type are dependent, a dependence likely mediated by either the space environment or differences in thrusters duty cycles; (5) Gridded ion thrusters exhibit both infant and wear-out failures, and thus would benefit from a reliability growth program that addresses both these types of problems.

  13. Comparative Reliability of Structured Versus Unstructured Interviews in the Admission Process of a Residency Program

    PubMed Central

    Blouin, Danielle; Day, Andrew G.; Pavlov, Andrey

    2011-01-01

    Background Although never directly compared, structured interviews are reported as being more reliable than unstructured interviews. This study compared the reliability of both types of interview when applied to a common pool of applicants for positions in an emergency medicine residency program. Methods In 2008, one structured interview was added to the two unstructured interviews traditionally used in our resident selection process. A formal job analysis using the critical incident technique guided the development of the structured interview tool. This tool consisted of 7 scenarios assessing 4 of the domains deemed essential for success as a resident in this program. The traditional interview tool assessed 5 general criteria. In addition to these criteria, the unstructured panel members were asked to rate each candidate on the same 4 essential domains rated by the structured panel members. All 3 panels interviewed all candidates. Main outcomes were the overall, interitem, and interrater reliabilities, the correlations between interview panels, and the dimensionality of each interview tool. Results Thirty candidates were interviewed. The overall reliability reached 0.43 for the structured interview, and 0.81 and 0.71 for the unstructured interviews. Analyses of the variance components showed a high interrater, low interitem reliability for the structured interview, and a high interrater, high interitem reliability for the unstructured interviews. The summary measures from the 2 unstructured interviews were significantly correlated, but neither was correlated with the structured interview. Only the structured interview was multidimensional. Conclusions A structured interview did not yield a higher overall reliability than both unstructured interviews. The lower reliability is explained by a lower interitem reliability, which in turn is due to the multidimensionality of the interview tool. Both unstructured panels consistently rated a single dimension, even when prompted to assess the 4 specific domains established as essential to succeed in this residency program. PMID:23205201

  14. Comparative reliability of structured versus unstructured interviews in the admission process of a residency program.

    PubMed

    Blouin, Danielle; Day, Andrew G; Pavlov, Andrey

    2011-12-01

    Although never directly compared, structured interviews are reported as being more reliable than unstructured interviews. This study compared the reliability of both types of interview when applied to a common pool of applicants for positions in an emergency medicine residency program. In 2008, one structured interview was added to the two unstructured interviews traditionally used in our resident selection process. A formal job analysis using the critical incident technique guided the development of the structured interview tool. This tool consisted of 7 scenarios assessing 4 of the domains deemed essential for success as a resident in this program. The traditional interview tool assessed 5 general criteria. In addition to these criteria, the unstructured panel members were asked to rate each candidate on the same 4 essential domains rated by the structured panel members. All 3 panels interviewed all candidates. Main outcomes were the overall, interitem, and interrater reliabilities, the correlations between interview panels, and the dimensionality of each interview tool. Thirty candidates were interviewed. The overall reliability reached 0.43 for the structured interview, and 0.81 and 0.71 for the unstructured interviews. Analyses of the variance components showed a high interrater, low interitem reliability for the structured interview, and a high interrater, high interitem reliability for the unstructured interviews. The summary measures from the 2 unstructured interviews were significantly correlated, but neither was correlated with the structured interview. Only the structured interview was multidimensional. A structured interview did not yield a higher overall reliability than both unstructured interviews. The lower reliability is explained by a lower interitem reliability, which in turn is due to the multidimensionality of the interview tool. Both unstructured panels consistently rated a single dimension, even when prompted to assess the 4 specific domains established as essential to succeed in this residency program.

  15. Measurement of fetal head descent using the 'angle of progression' on transperineal ultrasound imaging is reliable regardless of fetal head station or ultrasound expertise.

    PubMed

    Dückelmann, A M; Bamberg, C; Michaelis, S A M; Lange, J; Nonnenmacher, A; Dudenhausen, J W; Kalache, K D

    2010-02-01

    To assess whether ultrasound experience or fetal head station affects the reliability of measurement of fetal head descent using the angle of progression on intrapartum ultrasound images obtained by a single experienced operator, and to determine reliability of measurements when images were acquired by different operators with variable ultrasound experience. One experienced obstetrician performed 44 transperineal ultrasound examinations of women at term and in prolonged second stage of labor with the fetus in the occipitoanterior position. Three midwives without ultrasound experience, three obstetricians with < 5 years' experience and three obstetricians with > 10 years' experience measured fetal head descent based on the angle of progression in the images obtained. The angle of progression was measured by two obstetricians in independent ultrasound examinations of 24 laboring women at term with the fetus in the cephalic position to allow assessment of the reliability of image acquisition. Intraclass correlation coefficients (ICCs) with 95% confidence interval (CI) were used to evaluate interobserver reliability and Bland-Altman analysis was used to assess interobserver agreement. In total, 444 measurements were performed and compared. Interobserver reliability with respect to offline image analysis was substantial (overall ICC, 0.72; 95% CI, 0.63-0.81). ICCs were 0.82 (95% CI, 0.70-0.89), 0.81 (95% CI, 0.71-0.88) and 0.61 (95% CI, 0.43-074) for observers with > 10 years', < 5 years' and no ultrasound experience, respectively. There were no significant differences between ICCs among observer groups according to ultrasound experience. Fetal head station did not affect reliability. Bland-Altman analysis indicated reasonable agreement between measurements obtained by two different operators with > 10 years' and < 5 years' ultrasound experience (bias, -1.09 degrees ; 95% limits of agreement, -8.76 to 6.58). The reliability of measurement of the angle of progression following separate image acquisition by two experienced operators was similar to the reliability of offline image analysis (ICC, 0.86; 95% CI, 0.70-0.93). Measurement of the angle of progression on transperineal ultrasound imaging is reliable regardless of fetal head station or the clinician's level of ultrasound experience.

  16. Empirical Recommendations for Improving the Stability of the Dot-Probe Task in Clinical Research

    PubMed Central

    Price, Rebecca B.; Kuckertz, Jennie M.; Siegle, Greg J.; Ladouceur, Cecile D.; Silk, Jennifer S.; Ryan, Neal D.; Dahl, Ronald E.; Amir, Nader

    2014-01-01

    The dot-probe task has been widely used in research to produce an index of biased attention based on reaction times (RTs). Despite its popularity, very few published studies have examined psychometric properties of the task, including test-retest reliability, and no previous study has examined reliability in clinically anxious samples or systematically explored the effects of task design and analysis decisions on reliability. In the current analysis, we utilized dot-probe data from three studies where attention bias towards threat-related faces was assessed at multiple (≥5) timepoints. Two of the studies were similar (adults with Social Anxiety Disorder, similar design features) while one was much more disparate (pediatric healthy volunteers, distinct task design). We explored the effects of analysis choices (e.g., bias score calculation formula, methods for outlier handling) on reliability and searched for convergence of findings across the three studies. We found that, when considering the three studies concurrently, the most reliable RT bias index utilized data from dot-bottom trials, comparing congruent to incongruent trials, with rescaled outliers, particularly after averaging across more than one assessment point. Although reliability of RT bias indices was moderate to low under most circumstances, within-session variability in bias (attention bias variability; ABV), a recently proposed RT index, was more reliable across sessions. Several eyetracking-based indices of attention bias (available in the pediatric healthy sample only) showed reliability that matched the optimal RT index (ABV). On the basis of these findings, we make specific recommendations to researchers using the dot probe, particularly those wishing to investigate individual differences and/or single-patient applications. PMID:25419646

  17. Accuracy and Reliability of Marker-Based Approaches to Scale the Pelvis, Thigh, and Shank Segments in Musculoskeletal Models.

    PubMed

    Kainz, Hans; Hoang, Hoa X; Stockton, Chris; Boyd, Roslyn R; Lloyd, David G; Carty, Christopher P

    2017-10-01

    Gait analysis together with musculoskeletal modeling is widely used for research. In the absence of medical images, surface marker locations are used to scale a generic model to the individual's anthropometry. Studies evaluating the accuracy and reliability of different scaling approaches in a pediatric and/or clinical population have not yet been conducted and, therefore, formed the aim of this study. Magnetic resonance images (MRI) and motion capture data were collected from 12 participants with cerebral palsy and 6 typically developed participants. Accuracy was assessed by comparing the scaled model's segment measures to the corresponding MRI measures, whereas reliability was assessed by comparing the model's segments scaled with the experimental marker locations from the first and second motion capture session. The inclusion of joint centers into the scaling process significantly increased the accuracy of thigh and shank segment length estimates compared to scaling with markers alone. Pelvis scaling approaches which included the pelvis depth measure led to the highest errors compared to the MRI measures. Reliability was similar between scaling approaches with mean ICC of 0.97. The pelvis should be scaled using pelvic width and height and the thigh and shank segment should be scaled using the proximal and distal joint centers.

  18. Validity and Reliability of the Upper Extremity Work Demands Scale.

    PubMed

    Jacobs, Nora W; Berduszek, Redmar J; Dijkstra, Pieter U; van der Sluis, Corry K

    2017-12-01

    Purpose To evaluate validity and reliability of the upper extremity work demands (UEWD) scale. Methods Participants from different levels of physical work demands, based on the Dictionary of Occupational Titles categories, were included. A historical database of 74 workers was added for factor analysis. Criterion validity was evaluated by comparing observed and self-reported UEWD scores. To assess structural validity, a factor analysis was executed. For reliability, the difference between two self-reported UEWD scores, the smallest detectable change (SDC), test-retest reliability and internal consistency were determined. Results Fifty-four participants were observed at work and 51 of them filled in the UEWD twice with a mean interval of 16.6 days (SD 3.3, range = 10-25 days). Criterion validity of the UEWD scale was moderate (r = .44, p = .001). Factor analysis revealed that 'force and posture' and 'repetition' subscales could be distinguished with Cronbach's alpha of .79 and .84, respectively. Reliability was good; there was no significant difference between repeated measurements. An SDC of 5.0 was found. Test-retest reliability was good (intraclass correlation coefficient for agreement = .84) and all item-total correlations were >.30. There were two pairs of highly related items. Conclusion Reliability of the UEWD scale was good, but criterion validity was moderate. Based on current results, a modified UEWD scale (2 items removed, 1 item reworded, divided into 2 subscales) was proposed. Since observation appeared to be an inappropriate gold standard, we advise to investigate other types of validity, such as construct validity, in further research.

  19. Braden scale (ALB) for assessing pressure ulcer risk in hospital patients: A validity and reliability study.

    PubMed

    Chen, Hong-Lin; Cao, Ying-Juan; Zhang, Wei; Wang, Jing; Huai, Bao-Sha

    2017-02-01

    The inter-rater reliability of Braden Scale is not so good. We modified the Braden(ALB) scale by defining nutrition subscale based on serum albumin, then assessed it's the validity and reliability in hospital patients. We designed a retrospective study for validity analysis, and a prospective study for reliability analysis. Receiver operating curve (ROC) and area under the curve (AUC) were used to evaluate the predictive validity. Intra-class correlation coefficient (ICC) was used to investigate the inter-rater reliability. Two thousand five hundred twenty-five patients were included for validity analysis, 76 patients (3.0%) developed pressure ulcer. Positive correlation was found between serum albumin and nutrition score in Braden scale (Spearman's coefficient 0.2203, P<0.0001). The AUCs for Braden scale and Braden(ALB) scale predicting pressure ulcer risk were 0.813 (95% CI 0.797-0.828; P<0.0001), and 0.859 (95% CI 0.845-0.872; P<0.0001), respectively. The Braden(ALB) scale was even more valid than the Braden scale (z=1.860, P=0.0628). In different age subgroups, the Braden(ALB) scale seems also more valid than the original Braden scale, but no statistically significant differences were found (P>0.05). The inter-rater reliability study showed the ICC-value for nutrition increased 45.9%, and increased 4.3% for total score. The Braden(ALB) scale has similar validity compared with the original Braden scale for in hospital patients. However, the inter-rater reliability was significantly increased. Copyright © 2016 Elsevier Inc. All rights reserved.

  20. Reliability of Computerized Neurocognitive Tests for Concussion Assessment: A Meta-Analysis.

    PubMed

    Farnsworth, James L; Dargo, Lucas; Ragan, Brian G; Kang, Minsoo

    2017-09-01

      Although widely used, computerized neurocognitive tests (CNTs) have been criticized because of low reliability and poor sensitivity. A systematic review was published summarizing the reliability of Immediate Post-Concussion Assessment and Cognitive Testing (ImPACT) scores; however, this was limited to a single CNT. Expansion of the previous review to include additional CNTs and a meta-analysis is needed. Therefore, our purpose was to analyze reliability data for CNTs using meta-analysis and examine moderating factors that may influence reliability.   A systematic literature search (key terms: reliability, computerized neurocognitive test, concussion) of electronic databases (MEDLINE, PubMed, Google Scholar, and SPORTDiscus) was conducted to identify relevant studies.   Studies were included if they met all of the following criteria: used a test-retest design, involved at least 1 CNT, provided sufficient statistical data to allow for effect-size calculation, and were published in English.   Two independent reviewers investigated each article to assess inclusion criteria. Eighteen studies involving 2674 participants were retained. Intraclass correlation coefficients were extracted to calculate effect sizes and determine overall reliability. The Fisher Z transformation adjusted for sampling error associated with averaging correlations. Moderator analyses were conducted to evaluate the effects of the length of the test-retest interval, intraclass correlation coefficient model selection, participant demographics, and study design on reliability. Heterogeneity was evaluated using the Cochran Q statistic.   The proportion of acceptable outcomes was greatest for the Axon Sports CogState Test (75%) and lowest for the ImPACT (25%). Moderator analyses indicated that the type of intraclass correlation coefficient model used significantly influenced effect-size estimates, accounting for 17% of the variation in reliability.   The Axon Sports CogState Test, which has a higher proportion of acceptable outcomes and shorter test duration relative to other CNTs, may be a reliable option; however, future studies are needed to compare the diagnostic accuracy of these instruments.

  1. Reliability of joint count assessment in rheumatoid arthritis: a systematic literature review.

    PubMed

    Cheung, Peter P; Gossec, Laure; Mak, Anselm; March, Lyn

    2014-06-01

    Joint counts are central to the assessment of rheumatoid arthritis (RA) but reliability is an issue. To evaluate the reliability and agreement of joint counts (intra-observer and inter-observer) by health care professionals (physicians, nurses, and metrologists) and patients in RA, and the impact of training and standardization on joint count reliability through a systematic literature review. Articles reporting joint count reliability or agreement in RA in PubMed, EMBase, and the Cochrane library between 1960 and 2012 were selected. Data were extracted regarding tender joint counts (TJCs) and swollen joint counts (SJCs) derived by physicians, metrologists, or patients for intra-observer and inter-observer reliability. In addition, methods and effects of training or standardization were extracted. Statistics expressing reliability such as intraclass correlation coefficients (ICCs) were extracted. Data analysis was primarily descriptive due to high heterogeneity. Twenty-eight studies on health care professionals (HCP) and 20 studies on patients were included. Intra-observer reliability for TJCs and SJCs was good for HCPs and patients (range of ICC: 0.49-0.98). Inter-observer reliability between HCPs for TJCs was higher than for SJCs (range of ICC: 0.64-0.88 vs. 0.29-0.98). Patient inter-observer reliability with HCPs as comparators was better for TJCs (range of ICC: 0.31-0.91) compared to SJCs (0.16-0.64). Nine studies (7 with HCPs and 2 with patients) evaluated consensus or training, with improvement in reliability of TJCs but conflicting evidence for SJCs. Intra- and inter-observer reliability was high for TJCs for HCPs and patients: among all groups, reliability was better for TJCs than SJCs. Inter-observer reliability of SJCs was poorer for patients than HCPs. Data were inconclusive regarding the potential for training to improve SJC reliability. Overall, the results support further evaluation for patient-reported joint counts as an outcome measure. © 2013 Published by Elsevier Inc.

  2. Psychometric properties of the Satisfaction with Life Scale (SWLS): secondary analysis of the Mexican Health and Aging Study.

    PubMed

    López-Ortega, Mariana; Torres-Castro, Sara; Rosas-Carrasco, Oscar

    2016-12-09

    The Satisfaction with Life Scale (SWLS) has been widely used and has proven to be a valid and reliable instrument for assessing satisfaction with life in diverse population groups, however, research on satisfaction with life and validation of different measuring instruments in Mexican adults is still lacking. The objective was to evaluate the psychometric properties of the Satisfaction with Life Scale (SWLS) in a representative sample of Mexican adults. This is a methodological study to evaluate a satisfaction with life scale in a sample of 13,220 Mexican adults 50 years of age or older from the 2012 Mexican Health and Aging Study. The scale's reliability (internal consistency) was analysed using Cronbach's alpha and inter-item correlations. An exploratory factor analysis was also performed. Known-groups validity was evaluated comparing good-health and bad-health participants. Comorbidity, perceived financial situation, self-reported general health, depression symptoms, and social support were included to evaluate the validity between these measures and the total score of the scale using Spearman's correlations. The analysis of the scale's reliability showed good internal consistency (α = 0.74). The exploratory factor analysis confirmed the existence of a unique factor structure that explained 54% of the variance. SWLS was related to depression, perceived health, financial situation, and social support, and these relations were all statistically significant (P < .01). There was significant difference in life satisfaction between the good- and bad-health groups. Results show good internal consistency and construct validity of the SWLS. These results are comparable with results from previous studies. Meeting the study's objective to validate the scale, the results show that the Spanish version of the SWLS is a reliable and valid measure of satisfaction with life in the Mexican context.

  3. Using the Reliability Theory for Assessing the Decision Confidence Probability for Comparative Life Cycle Assessments.

    PubMed

    Wei, Wei; Larrey-Lassalle, Pyrène; Faure, Thierry; Dumoulin, Nicolas; Roux, Philippe; Mathias, Jean-Denis

    2016-03-01

    Comparative decision making process is widely used to identify which option (system, product, service, etc.) has smaller environmental footprints and for providing recommendations that help stakeholders take future decisions. However, the uncertainty problem complicates the comparison and the decision making. Probability-based decision support in LCA is a way to help stakeholders in their decision-making process. It calculates the decision confidence probability which expresses the probability of a option to have a smaller environmental impact than the one of another option. Here we apply the reliability theory to approximate the decision confidence probability. We compare the traditional Monte Carlo method with a reliability method called FORM method. The Monte Carlo method needs high computational time to calculate the decision confidence probability. The FORM method enables us to approximate the decision confidence probability with fewer simulations than the Monte Carlo method by approximating the response surface. Moreover, the FORM method calculates the associated importance factors that correspond to a sensitivity analysis in relation to the probability. The importance factors allow stakeholders to determine which factors influence their decision. Our results clearly show that the reliability method provides additional useful information to stakeholders as well as it reduces the computational time.

  4. Electrodynamic actuators for rocket engine valves

    NASA Technical Reports Server (NTRS)

    Fiet, O.; Doshi, D.

    1972-01-01

    Actuators, employed in acoustic loudspeakers, operate liquid rocket engine valves by replacing light paper cones with flexible metal diaphragms. Comparative analysis indicates better response time than solenoid actuators, and improved service life and reliability.

  5. Comparative analysis of different configurations of PLC-based safety systems from reliability point of view

    NASA Technical Reports Server (NTRS)

    Tapia, Moiez A.

    1993-01-01

    The study of a comparative analysis of distinct multiplex and fault-tolerant configurations for a PLC-based safety system from a reliability point of view is presented. It considers simplex, duplex and fault-tolerant triple redundancy configurations. The standby unit in case of a duplex configuration has a failure rate which is k times the failure rate of the standby unit, the value of k varying from 0 to 1. For distinct values of MTTR and MTTF of the main unit, MTBF and availability for these configurations are calculated. The effect of duplexing only the PLC module or only the sensors and the actuators module, on the MTBF of the configuration, is also presented. The results are summarized and merits and demerits of various configurations under distinct environments are discussed.

  6. Issues in benchmarking human reliability analysis methods : a literature review.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lois, Erasmia; Forester, John Alan; Tran, Tuan Q.

    There is a diversity of human reliability analysis (HRA) methods available for use in assessing human performance within probabilistic risk assessment (PRA). Due to the significant differences in the methods, including the scope, approach, and underlying models, there is a need for an empirical comparison investigating the validity and reliability of the methods. To accomplish this empirical comparison, a benchmarking study is currently underway that compares HRA methods with each other and against operator performance in simulator studies. In order to account for as many effects as possible in the construction of this benchmarking study, a literature review was conducted,more » reviewing past benchmarking studies in the areas of psychology and risk assessment. A number of lessons learned through these studies are presented in order to aid in the design of future HRA benchmarking endeavors.« less

  7. Issues in Benchmarking Human Reliability Analysis Methods: A Literature Review

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ronald L. Boring; Stacey M. L. Hendrickson; John A. Forester

    There is a diversity of human reliability analysis (HRA) methods available for use in assessing human performance within probabilistic risk assessments (PRA). Due to the significant differences in the methods, including the scope, approach, and underlying models, there is a need for an empirical comparison investigating the validity and reliability of the methods. To accomplish this empirical comparison, a benchmarking study comparing and evaluating HRA methods in assessing operator performance in simulator experiments is currently underway. In order to account for as many effects as possible in the construction of this benchmarking study, a literature review was conducted, reviewing pastmore » benchmarking studies in the areas of psychology and risk assessment. A number of lessons learned through these studies are presented in order to aid in the design of future HRA benchmarking endeavors.« less

  8. Patient safety in surgical environments: cross-countries comparison of psychometric properties and results of the Norwegian version of the Hospital Survey on Patient Safety.

    PubMed

    Haugen, Arvid S; Søfteland, Eirik; Eide, Geir E; Nortvedt, Monica W; Aase, Karina; Harthug, Stig

    2010-09-22

    How hospital health care personnel perceive safety climate has been assessed in several countries by using the Hospital Survey on Patient Safety (HSOPS). Few studies have examined safety climate factors in surgical departments per se. This study examined the psychometric properties of a Norwegian translation of the HSOPS and also compared safety climate factors from a surgical setting to hospitals in the United States, the Netherlands and Norway. This survey included 575 surgical personnel in Haukeland University Hospital in Bergen, an 1100-bed tertiary hospital in western Norway: surgeons, operating theatre nurses, anaesthesiologists, nurse anaesthetists and ancillary personnel. Of these, 358 returned the HSOPS, resulting in a 62% response rate. We used factor analysis to examine the applicability of the HSOPS factor structure in operating theatre settings. We also performed psychometric analysis for internal consistency and construct validity. In addition, we compared the percent of average positive responds of the patient safety climate factors with results of the US HSOPS 2010 comparative data base report. The professions differed in their perception of patient safety climate, with anaesthesia personnel having the highest mean scores. Factor analysis using the original 12-factor model of the HSOPS resulted in low reliability scores (r = 0.6) for two factors: "adequate staffing" and "organizational learning and continuous improvement". For the remaining factors, reliability was ≥ 0.7. Reliability scores improved to r = 0.8 by combining the factors "organizational learning and continuous improvement" and "feedback and communication about error" into one six-item factor, supporting an 11-factor model. The inter-item correlations were found satisfactory. The psychometric properties of the questionnaire need further investigations to be regarded as reliable in surgical environments. The operating theatre personnel perceived their hospital's patient safety climate far more negatively than the health care personnel in hospitals in the United States and with perceptions more comparable to those of health care personnel in hospitals in the Netherlands. In fact, the surgical personnel in our hospital may perceive that patient safety climate is less focused in our hospital, at least compared with the results from hospitals in the United States.

  9. Reliability and validity of urinary nerve growth factor measurement in women with lower urinary tract symptoms.

    PubMed

    Vijaya, Gopalan; Cartwright, Rufus; Bhide, Alka; Derpapas, Alexandros; Fernando, Ruwan; Khullar, Vik

    2016-11-01

    The validity and reliability of measurement of urinary NGF as a diagnostic biomarker in women with lower urinary tract dysfunction (LUTD) is uncertain. We aimed to evaluate both the diagnostic and discriminant validity, and the test-retest reliability of urinary NGF measurement in women with LUTD. Urinary NGF was measured in women with LUTD (n = 205) and asymptomatic subjects (n = 31). Urinary NGF was assayed using an ELISA method and normalized against urinary creatinine. NGF/creatinine ratios were compared between symptom subgroups using Mann-Whitney U test, and between different urodynamic diagnoses using the Kruskal-Wallis test. Receiver Operator Characteristic (ROC) analysis was employed to evaluate the diagnostic performance of urinary NGF. Test-retest reliability of NGF measurement was assessed using intra-class correlation (ICC). Urinary NGF was significantly but non-specifically increased in symptomatic patients when compared to controls (13.33 vs. 2.05 ng NGF/g Cr, P < 0.001). On multivariate logistic regression NGF was a good predictor of patients having OAB or not, however, the adjusted odds ratio only 1.006. ROC analysis demonstrated poor discriminant ability between different symptomatic groups and urodynamic groups. Using a cut off of 13.0 ng NGF/g creatinine the test provides a sensitivity of 81%, but a specificity of only 39% for overactive bladder. The assays demonstrated good test-retest reliability with ICC of 0.889. Although urinary NGF can be reliably assayed, and is increased in various LUTDs, it discriminates poorly between these disorders therefore has very limited potential as a biomarker. Neurourol. Urodynam. 35:944-948, 2016. © 2015 Wiley Periodicals, Inc. © 2015 Wiley Periodicals, Inc.

  10. Application of objective clinical human reliability analysis (OCHRA) in assessment of technical performance in laparoscopic rectal cancer surgery.

    PubMed

    Foster, J D; Miskovic, D; Allison, A S; Conti, J A; Ockrim, J; Cooper, E J; Hanna, G B; Francis, N K

    2016-06-01

    Laparoscopic rectal resection is technically challenging, with outcomes dependent upon technical performance. No robust objective assessment tool exists for laparoscopic rectal resection surgery. This study aimed to investigate the application of the objective clinical human reliability analysis (OCHRA) technique for assessing technical performance of laparoscopic rectal surgery and explore the validity and reliability of this technique. Laparoscopic rectal cancer resection operations were described in the format of a hierarchical task analysis. Potential technical errors were defined. The OCHRA technique was used to identify technical errors enacted in videos of twenty consecutive laparoscopic rectal cancer resection operations from a single site. The procedural task, spatial location, and circumstances of all identified errors were logged. Clinical validity was assessed through correlation with clinical outcomes; reliability was assessed by test-retest. A total of 335 execution errors identified, with a median 15 per operation. More errors were observed during pelvic tasks compared with abdominal tasks (p < 0.001). Within the pelvis, more errors were observed during dissection on the right side than the left (p = 0.03). Test-retest confirmed reliability (r = 0.97, p < 0.001). A significant correlation was observed between error frequency and mesorectal specimen quality (r s = 0.52, p = 0.02) and with blood loss (r s = 0.609, p = 0.004). OCHRA offers a valid and reliable method for evaluating technical performance of laparoscopic rectal surgery.

  11. Reliability Assessment for Low-cost Unmanned Aerial Vehicles

    NASA Astrophysics Data System (ADS)

    Freeman, Paul Michael

    Existing low-cost unmanned aerospace systems are unreliable, and engineers must blend reliability analysis with fault-tolerant control in novel ways. This dissertation introduces the University of Minnesota unmanned aerial vehicle flight research platform, a comprehensive simulation and flight test facility for reliability and fault-tolerance research. An industry-standard reliability assessment technique, the failure modes and effects analysis, is performed for an unmanned aircraft. Particular attention is afforded to the control surface and servo-actuation subsystem. Maintaining effector health is essential for safe flight; failures may lead to loss of control incidents. Failure likelihood, severity, and risk are qualitatively assessed for several effector failure modes. Design changes are recommended to improve aircraft reliability based on this analysis. Most notably, the control surfaces are split, providing independent actuation and dual-redundancy. The simulation models for control surface aerodynamic effects are updated to reflect the split surfaces using a first-principles geometric analysis. The failure modes and effects analysis is extended by using a high-fidelity nonlinear aircraft simulation. A trim state discovery is performed to identify the achievable steady, wings-level flight envelope of the healthy and damaged vehicle. Tolerance of elevator actuator failures is studied using familiar tools from linear systems analysis. This analysis reveals significant inherent performance limitations for candidate adaptive/reconfigurable control algorithms used for the vehicle. Moreover, it demonstrates how these tools can be applied in a design feedback loop to make safety-critical unmanned systems more reliable. Control surface impairments that do occur must be quickly and accurately detected. This dissertation also considers fault detection and identification for an unmanned aerial vehicle using model-based and model-free approaches and applies those algorithms to experimental faulted and unfaulted flight test data. Flight tests are conducted with actuator faults that affect the plant input and sensor faults that affect the vehicle state measurements. A model-based detection strategy is designed and uses robust linear filtering methods to reject exogenous disturbances, e.g. wind, while providing robustness to model variation. A data-driven algorithm is developed to operate exclusively on raw flight test data without physical model knowledge. The fault detection and identification performance of these complementary but different methods is compared. Together, enhanced reliability assessment and multi-pronged fault detection and identification techniques can help to bring about the next generation of reliable low-cost unmanned aircraft.

  12. Impact of Rating Scale Categories on Reliability and Fit Statistics of the Malay Spiritual Well-Being Scale using Rasch Analysis.

    PubMed

    Daher, Aqil Mohammad; Ahmad, Syed Hassan; Winn, Than; Selamat, Mohd Ikhsan

    2015-01-01

    Few studies have employed the item response theory in examining reliability. We conducted this study to examine the effect of Rating Scale Categories (RSCs) on the reliability and fit statistics of the Malay Spiritual Well-Being Scale, employing the Rasch model. The Malay Spiritual Well-Being Scale (SWBS) with the original six; three and four newly structured RSCs was distributed randomly among three different samples of 50 participants each. The mean age of respondents in the three samples ranged between 36 and 39 years old. The majority was female in all samples, and Islam was the most prevalent religion among the respondents. The predominating race was Malay, followed by Chinese and Indian. The original six RSCs indicated better targeting of 0.99 and smallest model error of 0.24. The Infit Mnsq (mean square) and Zstd (Z standard) of the six RSCs were "1.1"and "-0.1"respectively. The six RSCs achieved the highest person and item reliabilities of 0.86 and 0.85 respectively. These reliabilities yielded the highest person (2.46) and item (2.38) separation indices compared to other the RSCs. The person and item reliability and, to a lesser extent, the fit statistics, were better with the six RSCs compared to the four and three RSCs.

  13. Constellation Ground Systems Launch Availability Analysis: Enhancing Highly Reliable Launch Systems Design

    NASA Technical Reports Server (NTRS)

    Gernand, Jeffrey L.; Gillespie, Amanda M.; Monaghan, Mark W.; Cummings, Nicholas H.

    2010-01-01

    Success of the Constellation Program's lunar architecture requires successfully launching two vehicles, Ares I/Orion and Ares V/Altair, within a very limited time period. The reliability and maintainability of flight vehicles and ground systems must deliver a high probability of successfully launching the second vehicle in order to avoid wasting the on-orbit asset launched by the first vehicle. The Ground Operations Project determined which ground subsystems had the potential to affect the probability of the second launch and allocated quantitative availability requirements to these subsystems. The Ground Operations Project also developed a methodology to estimate subsystem reliability, availability, and maintainability to ensure that ground subsystems complied with allocated launch availability and maintainability requirements. The verification analysis developed quantitative estimates of subsystem availability based on design documentation, testing results, and other information. Where appropriate, actual performance history was used to calculate failure rates for legacy subsystems or comparative components that will support Constellation. The results of the verification analysis will be used to assess compliance with requirements and to highlight design or performance shortcomings for further decision making. This case study will discuss the subsystem requirements allocation process, describe the ground systems methodology for completing quantitative reliability, availability, and maintainability analysis, and present findings and observation based on analysis leading to the Ground Operations Project Preliminary Design Review milestone.

  14. Comprehensive reliability allocation method for CNC lathes based on cubic transformed functions of failure mode and effects analysis

    NASA Astrophysics Data System (ADS)

    Yang, Zhou; Zhu, Yunpeng; Ren, Hongrui; Zhang, Yimin

    2015-03-01

    Reliability allocation of computerized numerical controlled(CNC) lathes is very important in industry. Traditional allocation methods only focus on high-failure rate components rather than moderate failure rate components, which is not applicable in some conditions. Aiming at solving the problem of CNC lathes reliability allocating, a comprehensive reliability allocation method based on cubic transformed functions of failure modes and effects analysis(FMEA) is presented. Firstly, conventional reliability allocation methods are introduced. Then the limitations of direct combination of comprehensive allocation method with the exponential transformed FMEA method are investigated. Subsequently, a cubic transformed function is established in order to overcome these limitations. Properties of the new transformed functions are discussed by considering the failure severity and the failure occurrence. Designers can choose appropriate transform amplitudes according to their requirements. Finally, a CNC lathe and a spindle system are used as an example to verify the new allocation method. Seven criteria are considered to compare the results of the new method with traditional methods. The allocation results indicate that the new method is more flexible than traditional methods. By employing the new cubic transformed function, the method covers a wider range of problems in CNC reliability allocation without losing the advantages of traditional methods.

  15. Probabilistic durability assessment of concrete structures in marine environments: Reliability and sensitivity analysis

    NASA Astrophysics Data System (ADS)

    Yu, Bo; Ning, Chao-lie; Li, Bing

    2017-03-01

    A probabilistic framework for durability assessment of concrete structures in marine environments was proposed in terms of reliability and sensitivity analysis, which takes into account the uncertainties under the environmental, material, structural and executional conditions. A time-dependent probabilistic model of chloride ingress was established first to consider the variations in various governing parameters, such as the chloride concentration, chloride diffusion coefficient, and age factor. Then the Nataf transformation was adopted to transform the non-normal random variables from the original physical space into the independent standard Normal space. After that the durability limit state function and its gradient vector with respect to the original physical parameters were derived analytically, based on which the first-order reliability method was adopted to analyze the time-dependent reliability and parametric sensitivity of concrete structures in marine environments. The accuracy of the proposed method was verified by comparing with the second-order reliability method and the Monte Carlo simulation. Finally, the influences of environmental conditions, material properties, structural parameters and execution conditions on the time-dependent reliability of concrete structures in marine environments were also investigated. The proposed probabilistic framework can be implemented in the decision-making algorithm for the maintenance and repair of deteriorating concrete structures in marine environments.

  16. Reliability and validity of the faculty evaluation instrument used at King Saud bin Abdulaziz University for Health Sciences: Results from the Haematology Course.

    PubMed

    Al-Eidan, Fahad; Baig, Lubna Ansari; Magzoub, Mohi-Eldin; Omair, Aamir

    2016-04-01

    To assess reliability and validity of evaluation tool using Haematology course as an example. The cross-sectional study was conducted at King Saud Bin Abdul Aziz University of Health Sciences, Riyadh, Saudi Arabia, in 2012, while data analysis was completed in 2013. The 27-item block evaluation instrument was developed by a multidisciplinary faculty after a comprehensive literature review. Validity of the questionnaire was confirmed using principal component analysis with varimax rotation and Kaiser normalisation. Identified factors were combined to get the internal consistency reliability of each factor. Student's t-test was used to compare mean ratings between male and female students for the faculty and block evaluation. Of the 116 subjects in the study, 80(69%) were males and 36(31%) were females. Reliability of the questionnaire was Cronbach's alpha 0.91. Factor analysis yielded a logically coherent 7 factor solution that explained 75% of the variation in the data. The factors were group dynamics in problem-based learning (alpha0.92), block administration (alpha 0.89), quality of objective structured clinical examination (alpha 0.86), block coordination (alpha 0.81), structure of problem-based learning (alpha 0.84), quality of written exam (alpha 0.91), and difficulty of exams (alpha0.41). Female students' opinion on depth of analysis and critical thinking was significantly higher than that of the males (p=0.03). The faculty evaluation tool used was found to be reliable, but its validity, as assessed through factor analysis, has to be interpreted with caution as the responders were less than the minimum required for factor analysis.

  17. Identifying reliable independent components via split-half comparisons

    PubMed Central

    Groppe, David M.; Makeig, Scott; Kutas, Marta

    2011-01-01

    Independent component analysis (ICA) is a family of unsupervised learning algorithms that have proven useful for the analysis of the electroencephalogram (EEG) and magnetoencephalogram (MEG). ICA decomposes an EEG/MEG data set into a basis of maximally temporally independent components (ICs) that are learned from the data. As with any statistic, a concern with using ICA is the degree to which the estimated ICs are reliable. An IC may not be reliable if ICA was trained on insufficient data, if ICA training was stopped prematurely or at a local minimum (for some algorithms), or if multiple global minima were present. Consequently, evidence of ICA reliability is critical for the credibility of ICA results. In this paper, we present a new algorithm for assessing the reliability of ICs based on applying ICA separately to split-halves of a data set. This algorithm improves upon existing methods in that it considers both IC scalp topographies and activations, uses a probabilistically interpretable threshold for accepting ICs as reliable, and requires applying ICA only three times per data set. As evidence of the method’s validity, we show that the method can perform comparably to more time intensive bootstrap resampling and depends in a reasonable manner on the amount of training data. Finally, using the method we illustrate the importance of checking the reliability of ICs by demonstrating that IC reliability is dramatically increased by removing the mean EEG at each channel for each epoch of data rather than the mean EEG in a prestimulus baseline. PMID:19162199

  18. Occupational Analysis for Human Resource Development: A Review of Utility of the Task Inventory. Research Report No. 25.

    ERIC Educational Resources Information Center

    Moore, Brian E.

    A review of the issues concerning the field of occupational analysis was undertaken in order to indicate the comparative strengths and weaknesses of the task inventory (TI). Specifically, the significance of the TI was assessed for reliability and validity, job analysis and evaluation, occupational restructuring and career ladder development, and…

  19. A stochastic simulation method for the assessment of resistive random access memory retention reliability

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Berco, Dan, E-mail: danny.barkan@gmail.com; Tseng, Tseung-Yuen, E-mail: tseng@cc.nctu.edu.tw

    This study presents an evaluation method for resistive random access memory retention reliability based on the Metropolis Monte Carlo algorithm and Gibbs free energy. The method, which does not rely on a time evolution, provides an extremely efficient way to compare the relative retention properties of metal-insulator-metal structures. It requires a small number of iterations and may be used for statistical analysis. The presented approach is used to compare the relative robustness of a single layer ZrO{sub 2} device with a double layer ZnO/ZrO{sub 2} one, and obtain results which are in good agreement with experimental data.

  20. Bem Sex Role Inventory Validation in the International Mobility in Aging Study.

    PubMed

    Ahmed, Tamer; Vafaei, Afshin; Belanger, Emmanuelle; Phillips, Susan P; Zunzunegui, Maria-Victoria

    2016-09-01

    This study investigated the measurement structure of the Bem Sex Role Inventory (BSRI) with different factor analysis methods. Most previous studies on validity applied exploratory factor analysis (EFA) to examine the BSRI. We aimed to assess the psychometric properties and construct validity of the 12-item short-form BSRI in a sample administered to 1,995 older adults from wave 1 of the International Mobility in Aging Study (IMIAS). We used Cronbach's alpha to assess internal consistency reliability and confirmatory factor analysis (CFA) to assess psychometric properties. EFA revealed a three-factor model, further confirmed by CFA and compared with the original two-factor structure model. Results revealed that a two-factor solution (instrumentality-expressiveness) has satisfactory construct validity and superior fit to data compared to the three-factor solution. The two-factor solution confirms expected gender differences in older adults. The 12-item BSRI provides a brief, psychometrically sound, and reliable instrument in international samples of older adults.

  1. Reliability of Physical Activity Measures During Free-Living Activities in People After Total Knee Arthroplasty.

    PubMed

    Almeida, Gustavo J; Irrgang, James J; Fitzgerald, G Kelley; Jakicic, John M; Piva, Sara R

    2016-06-01

    Few instruments that measure physical activity (PA) can accurately quantify PA performed at light and moderate intensities, which is particularly relevant in older adults. The evidence of their reliability in free-living conditions is limited. The study objectives were: (1) to determine the test-retest reliability of the Actigraph (ACT), SenseWear Armband (SWA), and Community Healthy Activities Model Program for Seniors (CHAMPS) questionnaire in assessing free-living PA at light and moderate intensities in people after total knee arthroplasty; (2) to compare the reliability of the 3 instruments relative to each other; and (3) to determine the reliability of commonly used monitoring time frames (24 hours, waking hours, and 10 hours from awakening). A one-group, repeated-measures design was used. Participants wore the activity monitors for 2 weeks, and the CHAMPS questionnaire was completed at the end of each week. Test-retest reliability was determined by using the intraclass correlation coefficient (ICC [2,k]) to compare PA measures from one week with those from the other week. Data from 28 participants who reported similar PA during the 2 weeks were included in the analysis. The mean age of these participants was 69 years (SD=8), and 75% of them were women. Reliability ranged from moderate to excellent for the ACT (ICC=.75-.86) and was excellent for the SWA (ICC=.93-.95) and the CHAMPS questionnaire (ICC=.86-.92). The 95% confidence intervals (95% CI) of the ICCs from the SWA were the only ones within the excellent reliability range (.85-.98). The CHAMPS questionnaire showed systematic bias, with less PA being reported in week 2. The reliability of PA measures in the waking-hour time frame was comparable to that in the 24-hour time frame and reflected most PA performed during this period. Reliability may be lower for time intervals longer than 1 week. All PA measures showed good reliability. The reliability of the ACT was lower than those of the SWA and the CHAMPS questionnaire. The SWA provided more precise reliability estimates. Wearing PA monitors during waking hours provided sufficiently reliable measures and can reduce the burden on people wearing them. © 2016 American Physical Therapy Association.

  2. Reliability and minimal detectable difference in multisegment foot kinematics during shod walking and running.

    PubMed

    Milner, Clare E; Brindle, Richard A

    2016-01-01

    There has been increased interest recently in measuring kinematics within the foot during gait. While several multisegment foot models have appeared in the literature, the Oxford foot model has been used frequently for both walking and running. Several studies have reported the reliability for the Oxford foot model, but most studies to date have reported reliability for barefoot walking. The purpose of this study was to determine between-day (intra-rater) and within-session (inter-trial) reliability of the modified Oxford foot model during shod walking and running and calculate minimum detectable difference for common variables of interest. Healthy adult male runners participated. Participants ran and walked in the gait laboratory for five trials of each. Three-dimensional gait analysis was conducted and foot and ankle joint angle time series data were calculated. Participants returned for a second gait analysis at least 5 days later. Intraclass correlation coefficients and minimum detectable difference were determined for walking and for running, to indicate both within-session and between-day reliability. Overall, relative variables were more reliable than absolute variables, and within-session reliability was greater than between-day reliability. Between-day intraclass correlation coefficients were comparable to those reported previously for adults walking barefoot. It is an extension in the use of the Oxford foot model to incorporate wearing a shoe while maintaining marker placement directly on the skin for each segment. These reliability data for walking and running will aid in the determination of meaningful differences in studies which use this model during shod gait. Copyright © 2015 Elsevier B.V. All rights reserved.

  3. Validity and reliability of the Brazilian version of the Work Ability Index questionnaire.

    PubMed

    Martinez, Maria Carmen; Latorre, Maria do Rosário Dias de Oliveira; Fischer, Frida Marina

    2009-06-01

    To evaluate the validity and reliability of the Portuguese language version of a work ability index. Cross sectional survey of a sample of 475 workers from an electrical company in the state of Sao Paulo, Southeastern Brazil (spread across ten municipalities in the Campinas area), carried out in 2005. The following aspects of the Brazilian version of the Work Ability Index were evaluated: construct validity, using factorial exploratory analysis, and discriminant capacity, by comparing mean Work Ability Index scores in two groups with different absenteeism levels; criterion validity, by determining the correlation between self-reported health and Work Ability Index score; and reliability, using Cronbach's alpha to determine the internal consistency of the questionnaire. Factorial analysis indicated three factors in the work ability construct: issues pertaining to 'mental resources' (20.6% of the variance), self-perceived work ability (18.9% of the variance), and presence of diseases and health-related limitations (18.4% of the variance). The index was capable of discriminating workers according to levels of absenteeism, identifying a significantly lower (p<0.0001) mean score among subjects with high absenteeism (37.2 points) when compared to those with low absenteeism (42.3 points). Criterion validity analysis showed a correlation between the index and all dimensions of health status analyzed (p<0.0001). Reliability of the index was high, with a Cronbach's alpha of 0.72. The Brazilian version of the Work Ability Index showed satisfactory psychometric properties with respect to construct validity, thus constituting an appropriate option for evaluating work ability in both individual and population-based settings.

  4. [Differentiation of geographic biovariants of smallpox virus by PCR].

    PubMed

    Babkin, I V; Babkina, I N

    2010-01-01

    Comparative analysis of amino acid and nucleotides sequences of ORFs located in extended segments of the terminal variable regions in variola virus genome detected a promising locus for viral genotyping according to the geographic origin. This is ORF O1L of VARV. The primers were calculated for synthesis of this ORF fragment by PCR, which makes it possible to distinguish South America-Western Africa genotype from other VARV strains. Subsequent RFLP analysis reliably differentiated Asian strains from African strains (except Western Africa isolates). This method has been tested using 16 VARV strains from various geographic regions. The developed approach is simple, fast and reliable.

  5. Reliability and Validity of the Korean Version of the Internet Addiction Test among College Students

    PubMed Central

    Lee, Kounseok; Lee, Hye-Kyung; Gyeong, Hyunsu; Yu, Byeongkwan; Song, Yul-Mai

    2013-01-01

    We developed a Korean translation of the Internet Addiction Test (KIAT), widely used self-report for internet addiction and tested its reliability and validity in a sample of college students. Two hundred seventy-nine college students at a national university completed the KIAT. Internal consistency and two week test-retest reliability were calculated from the data, and principal component factor analysis was conducted. Participants also completed the Internet Addiction Diagnostic Questionnaire (IADQ), the Korea Internet addiction scale (K-scale), and the Patient Health Questionnaire-9 for the criterion validity. Cronbach's alpha of the whole scale was 0.91, and test-retest reliability was also good (r = 0.73). The IADQ, the K-scale, and depressive symptoms were significantly correlated with the KIAT scores, demonstrating concurrent and convergent validity. The factor analysis extracted four factors (Excessive use, Dependence, Withdrawal, and Avoidance of reality) that accounted for 59% of total variance. The KIAT has outstanding internal consistency and high test-retest reliability. Also, the factor structure and validity data show that the KIAT is comparable to the original version. Thus, the KIAT is a psychometrically sound tool for assessing internet addiction in the Korean-speaking population. PMID:23678270

  6. Exploring the validity and reliability of a questionnaire for evaluating veterinary clinical teachers' supervisory skills during clinical rotations.

    PubMed

    Boerboom, T B B; Dolmans, D H J M; Jaarsma, A D C; Muijtjens, A M M; Van Beukelen, P; Scherpbier, A J J A

    2011-01-01

    Feedback to aid teachers in improving their teaching requires validated evaluation instruments. When implementing an evaluation instrument in a different context, it is important to collect validity evidence from multiple sources. We examined the validity and reliability of the Maastricht Clinical Teaching Questionnaire (MCTQ) as an instrument to evaluate individual clinical teachers during short clinical rotations in veterinary education. We examined four sources of validity evidence: (1) Content was examined based on theory of effective learning. (2) Response process was explored in a pilot study. (3) Internal structure was assessed by confirmatory factor analysis using 1086 student evaluations and reliability was examined utilizing generalizability analysis. (4) Relations with other relevant variables were examined by comparing factor scores with other outcomes. Content validity was supported by theory underlying the cognitive apprenticeship model on which the instrument is based. The pilot study resulted in an additional question about supervision time. A five-factor model showed a good fit with the data. Acceptable reliability was achievable with 10-12 questionnaires per teacher. Correlations between the factors and overall teacher judgement were strong. The MCTQ appears to be a valid and reliable instrument to evaluate clinical teachers' performance during short rotations.

  7. Precision of lumbar intervertebral measurements: does a computer-assisted technique improve reliability?

    PubMed

    Pearson, Adam M; Spratt, Kevin F; Genuario, James; McGough, William; Kosman, Katherine; Lurie, Jon; Sengupta, Dilip K

    2011-04-01

    Comparison of intra- and interobserver reliability of digitized manual and computer-assisted intervertebral motion measurements and classification of "instability." To determine if computer-assisted measurement of lumbar intervertebral motion on flexion-extension radiographs improves reliability compared with digitized manual measurements. Many studies have questioned the reliability of manual intervertebral measurements, although few have compared the reliability of computer-assisted and manual measurements on lumbar flexion-extension radiographs. Intervertebral rotation, anterior-posterior (AP) translation, and change in anterior and posterior disc height were measured with a digitized manual technique by three physicians and by three other observers using computer-assisted quantitative motion analysis (QMA) software. Each observer measured 30 sets of digital flexion-extension radiographs (L1-S1) twice. Shrout-Fleiss intraclass correlation coefficients for intra- and interobserver reliabilities were computed. The stability of each level was also classified (instability defined as >4 mm AP translation or 10° rotation), and the intra- and interobserver reliabilities of the two methods were compared using adjusted percent agreement (APA). Intraobserver reliability intraclass correlation coefficients were substantially higher for the QMA technique THAN the digitized manual technique across all measurements: rotation 0.997 versus 0.870, AP translation 0.959 versus 0.557, change in anterior disc height 0.962 versus 0.770, and change in posterior disc height 0.951 versus 0.283. The same pattern was observed for interobserver reliability (rotation 0.962 vs. 0.693, AP translation 0.862 vs. 0.151, change in anterior disc height 0.862 vs. 0.373, and change in posterior disc height 0.730 vs. 0.300). The QMA technique was also more reliable for the classification of "instability." Intraobserver APAs ranged from 87 to 97% for QMA versus 60% to 73% for digitized manual measurements, while interobserver APAs ranged from 91% to 96% for QMA versus 57% to 63% for digitized manual measurements. The use of QMA software substantially improved the reliability of lumbar intervertebral measurements and the classification of instability based on flexion-extension radiographs.

  8. Agreement between the spatio-temporal gait parameters from treadmill-based photoelectric cell and the instrumented treadmill system in healthy young adults and stroke patients.

    PubMed

    Lee, Myungmo; Song, Changho; Lee, Kyoungjin; Shin, Doochul; Shin, Seungho

    2014-07-14

    Treadmill gait analysis was more advantageous than over-ground walking because it allowed continuous measurements of the gait parameters. The purpose of this study was to investigate the concurrent validity and the test-retest reliability of the OPTOGait photoelectric cell system against the treadmill-based gait analysis system by assessing spatio-temporal gait parameters. Twenty-six stroke patients and 18 healthy adults were asked to walk on the treadmill at their preferred speed. The concurrent validity was assessed by comparing data obtained from the 2 systems, and the test-retest reliability was determined by comparing data obtained from the 1st and the 2nd session of the OPTOGait system. The concurrent validity, identified by the intra-class correlation coefficients (ICC [2, 1]), coefficients of variation (CVME), and 95% limits of agreement (LOA) for the spatial-temporal gait parameters, were excellent but the temporal parameters expressed as a percentage of the gait cycle were poor. The test-retest reliability of the OPTOGait System, identified by ICC (3, 1), CVME, 95% LOA, standard error of measurement (SEM), and minimum detectable change (MDC95%) for the spatio-temporal gait parameters, was high. These findings indicated that the treadmill-based OPTOGait System had strong concurrent validity and test-retest reliability. This portable system could be useful for clinical assessments.

  9. Reliability of functional and predictive methods to estimate the hip joint centre in human motion analysis in healthy adults.

    PubMed

    Kainz, Hans; Hajek, Martin; Modenese, Luca; Saxby, David J; Lloyd, David G; Carty, Christopher P

    2017-03-01

    In human motion analysis predictive or functional methods are used to estimate the location of the hip joint centre (HJC). It has been shown that the Harrington regression equations (HRE) and geometric sphere fit (GSF) method are the most accurate predictive and functional methods, respectively. To date, the comparative reliability of both approaches has not been assessed. The aims of this study were to (1) compare the reliability of the HRE and the GSF methods, (2) analyse the impact of the number of thigh markers used in the GSF method on the reliability, (3) evaluate how alterations to the movements that comprise the functional trials impact HJC estimations using the GSF method, and (4) assess the influence of the initial guess in the GSF method on the HJC estimation. Fourteen healthy adults were tested on two occasions using a three-dimensional motion capturing system. Skin surface marker positions were acquired while participants performed quite stance, perturbed and non-perturbed functional trials, and walking trials. Results showed that the HRE were more reliable in locating the HJC than the GSF method. However, comparison of inter-session hip kinematics during gait did not show any significant difference between the approaches. Different initial guesses in the GSF method did not result in significant differences in the final HJC location. The GSF method was sensitive to the functional trial performance and therefore it is important to standardize the functional trial performance to ensure a repeatable estimate of the HJC when using the GSF method. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Meta-analytic guidelines for evaluating single-item reliabilities of personality instruments.

    PubMed

    Spörrle, Matthias; Bekk, Magdalena

    2014-06-01

    Personality is an important predictor of various outcomes in many social science disciplines. However, when personality traits are not the principal focus of research, for example, in global comparative surveys, it is often not possible to assess them extensively. In this article, we first provide an overview of the advantages and challenges of single-item measures of personality, a rationale for their construction, and a summary of alternative ways of assessing their reliability. Second, using seven diverse samples (Ntotal = 4,263) we develop the SIMP-G, the German adaptation of the Single-Item Measures of Personality, an instrument assessing the Big Five with one item per trait, and evaluate its validity and reliability. Third, we integrate previous research and our data into a first meta-analysis of single-item reliabilities of personality measures, and provide researchers with guidelines and recommendations for the evaluation of single-item reliabilities. © The Author(s) 2013.

  11. Verification of reliability and validity of a Japanese version of the Rathus Assertiveness Schedule.

    PubMed

    Suzuki, Eiko; Kanoya, Yuka; Katsuki, Takeshi; Sato, Chifumi

    2007-07-01

    To verify the reliability and validity of a Japanese version of the Rathus Assertiveness Schedule in novice nurses to contribute to nursing management. An adequate scale is needed to measure the assertiveness and the effect of assertion training for Japanese nurses and to compare them with those in other countries. Rathus Assertiveness Schedule was adapted to Japanese with back-translation and its validity was examined in 989 novice nurses. The Japanese version showed a high coefficient of reliability in a split-half reliability test (r=0.76; P<0.01). The coefficient of reliability of Cronbach's alpha was high (r=0.84; P<0.01) indicating high internal consistency. The similarity with the concept of stress coping was shown. We extracted eight principal factors using factor analysis with varimax rotation. Elements of these factors were similar to those of the original Rathus Assertiveness Schedule. The Japanese version of Rathus Assertiveness Schedule was verified.

  12. A new principle for the standardization of long paragraphs for reading speed analysis.

    PubMed

    Radner, Wolfgang; Radner, Stephan; Diendorfer, Gabriela

    2016-01-01

    To investigate the reliability, validity, and statistical comparability of long paragraphs that were developed to be equivalent in construction and difficulty. Seven long paragraphs were developed that were equal in syntax, morphology, and number and position of words (111), with the same number of syllables (179) and number of characters (660). For validity analyses, the paragraphs were compared with the mean reading speed of a set of seven sentence optotypes of the RADNER Reading Charts (mean of 7 × 14 = 98 words read). Reliability analyses were performed by calculating the Cronbach's alpha value and the corrected total item correlation. Sixty participants (aged 20-77 years) read the paragraphs and the sentences (distance 40 cm; font: Times New Roman 12 pt). Test items were presented randomly; reading length was measured with a stopwatch. Reliability analysis yielded a Cronbach's alpha value of 0.988. When the long paragraphs were compared in pairwise fashion, significant differences were found in 13 of the 21 pairs (p < 0.05). In two sequences of three paragraphs each and in eight pairs of paragraphs, the paragraphs did not differ significantly, and these paragraph combinations are therefore suitable for comparative research studies. The mean reading speed was 173.34 ± 24.01 words per minute (wpm) for the long paragraphs and 198.26 ± 28.60 wpm for the sentence optotypes. The maximum difference in reading speed was 5.55 % for the long paragraphs and 2.95 % for the short sentence optotypes. The correlation between long paragraphs and sentence optotypes was high (r = 0.9243). Despite good reliability and equivalence in construction and degree of difficulty, a statistically significant difference in reading speed can occur between long paragraphs. Since statistical significance should be dependent only on the persons tested, either standardizing long paragraphs for statistical equality of reading speed measurements or increasing the number of presented paragraphs is recommended for comparative investigations.

  13. Measurement of stain on extracted teeth using spectrophotometry and digital image analysis.

    PubMed

    Lath, D L; Smith, R N; Guan, Y H; Karmo, M; Brook, A H

    2007-08-01

    The aim of this study was to assess the reliability and validate a customized image analysis system, designed for use within clinical trials of general dental hygiene and whitening products, for the measurement of stain levels on extracted teeth and to compare it with reflectance spectrophotometry. Twenty non-carious extracted teeth were soaked in an artificial saliva, brushed for 1 min using an electric toothbrush and a standard toothpaste, bleached using a 5.3% hydrogen peroxide solution and cycled for 6 h daily through a tea solution. CIE L* values were obtained after each treatment step using the customized image analysis system and a reflectance spectrophotometer. A statistical analysis was carried out in SPSS. Fleiss' coefficient of reliability for intra-operator repeatability of the image analysis system and spectrophotometry was 0.996 and 0.946 respectively. CIE L* values were consistently higher using the image analysis compared with spectrophotometry, and t-tests for each treatment step showed significant differences (P < 0.05) for the two methods. Limits of agreement between the methods were -27.95 to +2.07, with a 95% confidence of the difference calculated as -14.26 to -11.84. The combined results for all treatment steps showed a significant difference between the methods for the CIE L* values (P < 0.05). The image analysis system has proven to be a reliable method for assessment of changes in stain level on extracted teeth. The method has been validated against reflectance spectrophotometry. This method may be used for pilot in vitro studies/trials of oral hygiene and whitening products, before expensive in vivo tests are carried out.

  14. Development of a Modified Korean East Asian Student Stress Inventory by Comparing Stress Levels in Medical Students with Those in Non-Medical Students.

    PubMed

    Shin, Hee Kon; Kang, Seok Hoon; Lim, Sun-Hye; Yang, Jeong Hee; Chae, Sunguk

    2016-01-01

    Medical students are usually under more stress than that experienced by non-medical students. Stress testing tools for Korean medical students have not been sufficiently studied. Thus, we adapted and modified the East Asian Student Stress Inventory (EASSI), a stress testing tool for Korean students studying abroad, and verified its usefulness as a stress test in Korean university students. We also compared and analyzed stress levels between medical and non-medical students. A questionnaire survey was conducted on medical and non-medical students of a national university, and the responses of 224 students were analyzed for this study. Factor analysis and reliability testing were performed based on data collected for 25 adapted EASSI questions and those on the Korean version of the Global Assessment of Recent Stress Scale (GARSS). A correlation analysis was performed between the 13 modified EASSI questions and the GARSS, and validity of the modified EASSI was verified by directly comparing stress levels between the two student groups. The 13 questions adapted for the EASSI were called the modified EASSI and classified into four factors through a factor analysis and reliability testing. The Pearson's correlation analysis revealed a significant correlation between the modified EASSI and the Korean version of the GARSS, suggesting a complementary strategy of using both tests. The validity and reliability of the EASSI were verified. The modified Korean EASSI could be a useful stress test for Korean medical students. Our results show that medical students were under more stress than that of non-medical students. Thus, these results could be helpful for managing stress in medical students.

  15. Rasch analysis of the Edmonton Symptom Assessment System and research implications.

    PubMed

    Cheifetz, O; Packham, T L; Macdermid, J C

    2014-04-01

    Reliable and valid assessment of the disease burden across all forms of cancer is critical to the evaluation of treatment effectiveness and patient progress. The Edmonton Symptom Assessment System (esas) is used for routine evaluation of people attending for cancer care. In the present study, we used Rasch analysis to explore the measurement properties of the esas and to determine the effect of using Rasch-proposed interval-level esas scoring compared with traditional scoring when evaluating the effects of an exercise program for cancer survivors. Polytomous Rasch analysis (Andrich's rating-scale model) was applied to data from 26,645 esas questionnaires completed at the Juravinski Cancer Centre. The fit of the esas to the polytomous Rasch model was investigated, including evaluations of differential item functioning for sex, age, and disease group. The research implication was investigated by comparing the results of an observational research study previously analysed using a traditional approach with the results obtained by Rasch-proposed interval-level esas scoring. The Rasch reliability index was 0.73, falling short of the desired 0.80-0.90 level. However, the esas was found to fit the Rasch model, including the criteria for uni-dimensional data. The analysis suggests that the current esas scoring system of 0-10 could be collapsed to a 6-point scale. Use of the Rasch-proposed interval-level scoring yielded results that were different from those calculated using summarized ordinal-level esas scores. Differential item functioning was not found for sex, age, or diagnosis groups. The esas is a moderately reliable uni-dimensional measure of cancer disease burden and can provide interval-level scaling with Rasch-based scoring. Further, our study indicates that, compared with the traditional scoring metric, Rasch-based scoring could result in substantive changes to conclusions.

  16. A critical analysis of test-retest reliability in instrument validation studies of cancer patients under palliative care: a systematic review

    PubMed Central

    2014-01-01

    Background Patient-reported outcome validation needs to achieve validity and reliability standards. Among reliability analysis parameters, test-retest reliability is an important psychometric property. Retested patients must be in a clinically stable condition. This is particularly problematic in palliative care (PC) settings because advanced cancer patients are prone to a faster rate of clinical deterioration. The aim of this study was to evaluate the methods by which multi-symptom and health-related qualities of life (HRQoL) based on patient-reported outcomes (PROs) have been validated in oncological PC settings with regards to test-retest reliability. Methods A systematic search of PubMed (1966 to June 2013), EMBASE (1980 to June 2013), PsychInfo (1806 to June 2013), CINAHL (1980 to June 2013), and SCIELO (1998 to June 2013), and specific PRO databases was performed. Studies were included if they described a set of validation studies. Studies were included if they described a set of validation studies for an instrument developed to measure multi-symptom or multidimensional HRQoL in advanced cancer patients under PC. The COSMIN checklist was used to rate the methodological quality of the study designs. Results We identified 89 validation studies from 746 potentially relevant articles. From those 89 articles, 31 measured test-retest reliability and were included in this review. Upon critical analysis of the overall quality of the criteria used to determine the test-retest reliability, 6 (19.4%), 17 (54.8%), and 8 (25.8%) of these articles were rated as good, fair, or poor, respectively, and no article was classified as excellent. Multi-symptom instruments were retested over a shortened interval when compared to the HRQoL instruments (median values 24 hours and 168 hours, respectively; p = 0.001). Validation studies that included objective confirmation of clinical stability in their design yielded better results for the test-retest analysis with regard to both pain and global HRQoL scores (p < 0.05). The quality of the statistical analysis and its description were of great concern. Conclusion Test-retest reliability has been infrequently and poorly evaluated. The confirmation of clinical stability was an important factor in our analysis, and we suggest that special attention be focused on clinical stability when designing a PRO validation study that includes advanced cancer patients under PC. PMID:24447633

  17. Exclusively visual analysis of classroom group interactions

    NASA Astrophysics Data System (ADS)

    Tucker, Laura; Scherr, Rachel E.; Zickler, Todd; Mazur, Eric

    2016-12-01

    Large-scale audiovisual data that measure group learning are time consuming to collect and analyze. As an initial step towards scaling qualitative classroom observation, we qualitatively coded classroom video using an established coding scheme with and without its audio cues. We find that interrater reliability is as high when using visual data only—without audio—as when using both visual and audio data to code. Also, interrater reliability is high when comparing use of visual and audio data to visual-only data. We see a small bias to code interactions as group discussion when visual and audio data are used compared with video-only data. This work establishes that meaningful educational observation can be made through visual information alone. Further, it suggests that after initial work to create a coding scheme and validate it in each environment, computer-automated visual coding could drastically increase the breadth of qualitative studies and allow for meaningful educational analysis on a far greater scale.

  18. Reliability analysis of hydrologic containment of liquefied petroleum gas within unlined rock caverns.

    NASA Astrophysics Data System (ADS)

    Gao, X.; Yan, E. C.; Yeh, T. C. J.; Wang, Y.; Liang, Y.; Hao, Y.

    2017-12-01

    Notice that most of the underground liquefied petroleum gas (LPG) storage caverns are constructed in unlined rock caverns (URCs), where the variability of hydraulic properties (in particular, hydraulic conductivity) has significant impacts on hydrologic containment performance. However, it is practically impossible to characterize the spatial distribution of these properties in detail at the site of URCs. This dilemma forces us to cope with uncertainty in our evaluations of gas containment. As a consequence, the uncertainty-based analysis is deemed more appropriate than the traditional deterministic analysis. The objectives of this paper are 1) to introduce a numerical first order method to calculate the gas containment reliability within a heterogeneous, two-dimensional unlined rock caverns, and 2) to suggest a strategy for improving the gas containment reliability. In order to achieve these goals, we first introduced the stochastic continuum representation of saturated hydraulic conductivity (Ks) of fractured rock and analyzed the spatial variability of Ks at a field site. We then conducted deterministic simulations to demonstrate the importance of heterogeneity of Ks in the analysis of gas tightness performance of URCs. Considering the uncertainty of the heterogeneity in the real world situations, we subsequently developed a numerical first order method (NFOM) to determine the gas tightness reliability at crucial locations of URCs. Using the NFOM, the effect of spatial variability of Ks on gas tightness reliability was investigated. Results show that as variance or spatial structure anisotropy of Ks increases, most of the gas tightness reliability at crucial locations reduces. Meanwhile, we compare the results of NFOM with those of Monte Carlo simulation, and we find the accuracy of NFOM is mainly affected by the magnitude of the variance of Ks. At last, for improving gas containment reliability at crucial locations at this study site, we suggest that vertical water-curtain holes should be installed in the pillar rather than increasing density of horizontal water-curtain boreholes.

  19. A Comparison of Various Stress Rupture Life Models for Orbiter Composite Pressure Vessels and Confidence Intervals

    NASA Technical Reports Server (NTRS)

    Grimes-Ledesma, Lorie; Murthy, Pappu L. N.; Phoenix, S. Leigh; Glaser, Ronald

    2007-01-01

    In conjunction with a recent NASA Engineering and Safety Center (NESC) investigation of flight worthiness of Kevlar Overwrapped Composite Pressure Vessels (COPVs) on board the Orbiter, two stress rupture life prediction models were proposed independently by Phoenix and by Glaser. In this paper, the use of these models to determine the system reliability of 24 COPVs currently in service on board the Orbiter is discussed. The models are briefly described, compared to each other, and model parameters and parameter uncertainties are also reviewed to understand confidence in reliability estimation as well as the sensitivities of these parameters in influencing overall predicted reliability levels. Differences and similarities in the various models will be compared via stress rupture reliability curves (stress ratio vs. lifetime plots). Also outlined will be the differences in the underlying model premises, and predictive outcomes. Sources of error and sensitivities in the models will be examined and discussed based on sensitivity analysis and confidence interval determination. Confidence interval results and their implications will be discussed for the models by Phoenix and Glaser.

  20. Use of volunteer student abstractors for a retrospective cohort analysis: a study of inter-rater reliability.

    PubMed

    Gritsiouk, Yaroslav; Hegsted, Damian; Gardiner, Stuart; Merriman, Lisa; Gubler, Kelly Dean

    2013-05-01

    Little is known about the reliability of data collected by abstractors without professional medical training. This investigation sought to determine the level of agreement among untrained volunteer abstractors as part of a study to evaluate the risk assessment of venous thromboembolism in patients who have undergone trauma. Forty-nine paper charts were chosen randomly from a volunteer-reviewed cohort of 2,339 and were compared with those of a single experienced abstractor. Inter-rater agreement was assessed using percent agreement, Cohen's kappa, and prevalence-adjusted bias-adjusted kappa (PABAK). Of the 71 data points, 28 had perfect agreement. The average agreement across all charts was 97%. Data with imperfect agreement had kappa values between .27 and .96 (mean, .75), with one additional value at zero even though it was associated with an agreement of 94%. PABAK values ranged from .67 to .98 (mean, .91), an average increase of .17 compared with kappa values. The performance of volunteers showed outstanding inter-rater reliability; however, limitations of interpretation can influence reliability. Copyright © 2013 Elsevier Inc. All rights reserved.

  1. A reliability analysis tool for SpaceWire network

    NASA Astrophysics Data System (ADS)

    Zhou, Qiang; Zhu, Longjiang; Fei, Haidong; Wang, Xingyou

    2017-04-01

    A SpaceWire is a standard for on-board satellite networks as the basis for future data-handling architectures. It is becoming more and more popular in space applications due to its technical advantages, including reliability, low power and fault protection, etc. High reliability is the vital issue for spacecraft. Therefore, it is very important to analyze and improve the reliability performance of the SpaceWire network. This paper deals with the problem of reliability modeling and analysis with SpaceWire network. According to the function division of distributed network, a reliability analysis method based on a task is proposed, the reliability analysis of every task can lead to the system reliability matrix, the reliability result of the network system can be deduced by integrating these entire reliability indexes in the matrix. With the method, we develop a reliability analysis tool for SpaceWire Network based on VC, where the computation schemes for reliability matrix and the multi-path-task reliability are also implemented. By using this tool, we analyze several cases on typical architectures. And the analytic results indicate that redundancy architecture has better reliability performance than basic one. In practical, the dual redundancy scheme has been adopted for some key unit, to improve the reliability index of the system or task. Finally, this reliability analysis tool will has a directive influence on both task division and topology selection in the phase of SpaceWire network system design.

  2. Service quality, patient satisfaction and loyalty in the Bangladesh healthcare sector.

    PubMed

    Ahmed, Selim; Tarique, Kazi Md; Arif, Ishtiaque

    2017-06-12

    Purpose The purpose of this paper is to investigate service quality, patient satisfaction and loyalty in Bangladesh's healthcare sector. It identifies healthcare quality conformance, patient satisfaction and loyalty based on demographics such as gender, age and marital status. It examines the differences between public and private healthcare sectors regarding service quality, patient satisfaction and loyalty. Design/methodology/approach The authors distributed 450 self-administered questionnaires to hospital patients resulting in 204 useful responses (45.3 per cent response rate). Data were analysed based on reliability analysis, exploratory factor analysis, independent samples t-tests, ANOVA and discriminant analysis using SPSS version 23. Findings Findings indicate that single patients perceive tangibles, reliability, empathy and loyalty higher compared to married patients. Young patients (⩽20 years) have a higher tangibles, empathy and loyalty scores compared to other age groups. The authors observed that private hospital patients perceive healthcare service quality performance higher compared to patients in public hospitals. Research limitations/implications The authors focussed solely on the Bangladesh health sector, so the results might not be applicable to other countries. Originality/value The findings provide guidelines for enhancing service quality, patient satisfaction and loyalty in the Bangladesh healthcare sector and other countries.

  3. [Study of the reliability in one dimensional size measurement with digital slit lamp microscope].

    PubMed

    Wang, Tao; Qi, Chaoxiu; Li, Qigen; Dong, Lijie; Yang, Jiezheng

    2010-11-01

    To study the reliability of digital slit lamp microscope as a tool for quantitative analysis in one dimensional size measurement. Three single-blinded observers acquired and repeatedly measured the images with a size of 4.00 mm and 10.00 mm on the vernier caliper, which simulatated the human eye pupil and cornea diameter under China-made digital slit lamp microscope in the objective magnification of 4 times, 10 times, 16 times, 25 times, 40 times and 4 times, 10 times, 16 times, respectively. The correctness and precision of measurement were compared. The images with 4 mm size were measured by three investigators and the average values were located between 3.98 to 4.06. For the images with 10.00 mm size, the average values fell within 10.00 ~ 10.04. Measurement results of 4.00 mm images showed, except A4, B25, C16 and C25, significant difference was noted between the measured value and the true value. Regarding measurement results of 10.00 mm iamges indicated, except A10, statistical significance was found between the measured value and the true value. In terms of comparing the results of the same size measured at different magnifications by the same investigator, except for investigators A's measurements of 10.00 mm dimension, the measurement results by all the remaining investigators presented statistical significance at different magnifications. Compared measurements of the same size with different magnifications, measurements of 4.00 mm in 4-fold magnification had no significant difference among the investigators', the remaining results were statistically significant. The coefficient of variation of all measurement results were less than 5%; as magnification increased, the coefficient of variation decreased. The measurement of digital slit lamp microscope in one-dimensional size has good reliability,and should be performed for reliability analysis before used for quantitative analysis to reduce systematic errors.

  4. Reliability of bounce drop jump parameters within elite male rugby players.

    PubMed

    Costley, Lisa; Wallace, Eric; Johnston, Michael; Kennedy, Rodney

    2017-07-25

    The aims of the study were to investigate the number of familiarisation sessions required to establish reliability of the bounce drop jump (BDJ) and subsequent reliability once familiarisation is achieved. Seventeen trained male athletes completed 4 BDJs in 4 separate testing sessions. Force-time data from a 20 cm BDJ was obtained using two force plates (ensuring ground contact < 250 ms). Subjects were instructed to 'jump for maximal height and minimal contact time' while the best and average of four jumps were compared. A series of performance variables were assessed in both eccentric and concentric phases including jump height, contact time, flight time, reactive strength index (RSI), peak power, rate of force development (RFD) and actual dropping height (ADH). Reliability was assessed using the intraclass correlation coefficient (ICC) and coefficient of variation (CV) while familiarisation was assessed using a repeated measures analysis of variance (ANOVA). The majority of DJ parameters exhibited excellent reliability with no systematic bias evident, while the average of 4 trials provided greater reliability. With the exception of vertical stiffness (CV: 12.0 %) and RFD (CV: 16.2 %) all variables demonstrated low within subject variation (CV range: 3.1 - 8.9 %). Relative reliability was very poor for ADH, with heights ranging from 14.87 - 29.85 cm. High levels of reliability can be obtained from the BDJ with the exception of vertical stiffness and RFD, however, extreme caution must be taken when comparing DJ results between individuals and squads due to large discrepancies between actual drop height and platform height.

  5. Research diagnostic criteria for temporomandibular disorders (RDC/TMD): development of image analysis criteria and examiner reliability for image analysis.

    PubMed

    Ahmad, Mansur; Hollender, Lars; Anderson, Quentin; Kartha, Krishnan; Ohrbach, Richard; Truelove, Edmond L; John, Mike T; Schiffman, Eric L

    2009-06-01

    As part of the Multisite Research Diagnostic Criteria For Temporomandibular Disorders (RDC/TMD) Validation Project, comprehensive temporomandibular joint diagnostic criteria were developed for image analysis using panoramic radiography, magnetic resonance imaging (MRI), and computerized tomography (CT). Interexaminer reliability was estimated using the kappa (kappa) statistic, and agreement between rater pairs was characterized by overall, positive, and negative percent agreement. Computerized tomography was the reference standard for assessing validity of other imaging modalities for detecting osteoarthritis (OA). For the radiologic diagnosis of OA, reliability of the 3 examiners was poor for panoramic radiography (kappa = 0.16), fair for MRI (kappa = 0.46), and close to the threshold for excellent for CT (kappa = 0.71). Using MRI, reliability was excellent for diagnosing disc displacements (DD) with reduction (kappa = 0.78) and for DD without reduction (kappa = 0.94) and good for effusion (kappa = 0.64). Overall percent agreement for pairwise ratings was >or=82% for all conditions. Positive percent agreement for diagnosing OA was 19% for panoramic radiography, 59% for MRI, and 84% for CT. Using MRI, positive percent agreement for diagnoses of any DD was 95% and of effusion was 81%. Negative percent agreement was >or=88% for all conditions. Compared with CT, panoramic radiography and MRI had poor and marginal sensitivity, respectively, but excellent specificity in detecting OA. Comprehensive image analysis criteria for the RDC/TMD Validation Project were developed, which can reliably be used for assessing OA using CT and for disc position and effusion using MRI.

  6. The active movement scale: an evaluative tool for infants with obstetrical brachial plexus palsy.

    PubMed

    Curtis, Christine; Stephens, Derek; Clarke, Howard M; Andrews, David

    2002-05-01

    Newborns with peripheral nerve lesions involving the upper extremity are difficult to evaluate. The reliability of the Active Movement Scale (AMS), a tool for assessing motor function in infants with obstetrical brachial plexus palsy (OBPP), was examined in 2 complementary studies. Part A was an interrater reliability study in which 63 infants younger than 1 year with OBPP were independently evaluated by 2 physical therapists using the AMS. The scores were compared for reliability and controlled for chance agreement by using kappa statistics. Overall kappa analysis of the 15 tested movements showed a moderate strength of score agreement (kappa = 0.51). Quadratic-weighted kappa (kappa(quad)) statistics showed that 8 of the 15 movements tested were in the highest strength of agreement category (kappa(quad) = 0.81-1.00). Five movements showed substantial agreement (kappa(quad) = 0.61-0.80), and 2 movements had moderate agreement (kappa(quad) = 0.41- 0.60). The overall kappa(quad) was 0.89. Part B was a variability study designed to examine the dispersion of scores when infants with OBPP were evaluated with the AMS by multiple raters. Ten pediatric physical therapists with varying degrees of experience using the scale attended a 1(1/2)-hour instructional workshop on administration of the tool for infants with OBPP. A chain-block study design was used to obtain 30 assessments of 10 infants by 10 raters. A 2-way analysis of variance indicated that the variability of scores due to rater factors was low compared with the variability due to patient factors and that variation in scores due to rater experience was minimal. The results of part A indicate that the AMS is a reliable tool for the assessment of infants with OBPP when raters familiar with the scale are compared. The results of part B suggest that, with minimal training, raters with a range of experience using the AMS are able to reliably evaluate infants with upper-extremity paralysis.

  7. Reliability of plain radiographic parameters for developmental dysplasia of the hip in children.

    PubMed

    Upasani, Vidyadhar V; Bomar, James D; Parikh, Gaurav; Hosalkar, Harish

    2012-07-01

    Few studies have evaluated the reliability and reproducibility of the femoral neck-shaft angle (NSA), center-edge angle (CEA), and acetabular index (AI) in young children with developmental dysplasia of the hip (DDH). We wanted to determine whether these parameters could be used reliably by practitioners. Fifty radiographs from 21 children with DDH were reviewed. Analysis was performed by three observers, at two time periods. The intra- and inter-observer reliability for each measure was assessed. At time period one, we noted a "high" level of agreement between observers when measuring the NSA, a "low" level when measuring the CEA, and a "moderate" level when measuring the AI. At time period two, we noted a "very high" level of agreement between observers when measuring the NSA and a "high" level when measuring the CEA and AI. When comparing the measurements of observer 1 at the two different time periods, we noted nearly "very high" agreement when measuring the NSA, a "moderate" agreement when measuring the CEA, and a "high" agreement for the AI. In comparing the measurements of observer 2, we noted "very high" agreement for the NSA and "high" agreement for the CEA and AI. In comparing the measurements for observer 3, we noted nearly "very high" agreement for the NSA, nearly "high" agreement for the CEA, and "high" agreement for the AI. It is difficult to reliably measure three-dimensional pelvic morphology on a frontal plane radiograph, especially when important pelvic landmarks have yet to ossify.

  8. Arm cranking versus wheelchair propulsion for testing aerobic fitness in children with spina bifida who are wheelchair dependent.

    PubMed

    Bloemen, Manon A T; de Groot, Janke F; Backx, Frank J G; Westerveld, Rosalyne A; Takken, Tim

    2015-05-01

    To determine the best test performance and feasibility using a Graded Arm Cranking Test vs a Graded Wheelchair Propulsion Test in young people with spina bifida who use a wheelchair, and to determine the reliability of the best test. Validity and reliability study. Young people with spina bifida who use a wheelchair. Physiological responses were measured during a Graded Arm Cranking Test and a Graded Wheelchair Propulsion Test using a heart rate monitor and calibrated mobile gas analysis system (Cortex Metamax). For validity, peak oxygen uptake (VO2peak) and peak heart rate (HRpeak) were compared using paired t-tests. For reliability, the intra-class correlation coefficients, standard error of measurement, and standard detectable change were calculated. VO2peak and HRpeak were higher during wheelchair propulsion compared with arm cranking (23.1 vs 19.5 ml/kg/min, p = 0.11; 165 vs 150 beats/min, p < 0.05). Reliability of wheelchair propulsion showed high intra-class correlation coefficients (ICCs) for both VO2peak (ICC = 0.93) and HRpeak (ICC = 0.90). This pilot study shows higher HRpeak and a tendency to higher VO2peak in young people with spina bifida who are using a wheelchair when tested during wheelchair propulsion compared with arm cranking. Wheelchair propulsion showed good reliability. We recommend performing a wheelchair propulsion test for aerobic fitness testing in this population.

  9. Suicide reporting content analysis: abstract development and reliability.

    PubMed

    Gould, Madelyn S; Midle, Jennifer Bassett; Insel, Beverly; Kleinman, Marjorie

    2007-01-01

    Despite substantial research on media influences and the development of media guidelines on suicide reporting, research on the specifics of media stories that facilitate suicide contagion has been limited. The goal of the present study was to develop a content analytic strategy to code features in media suicide reports presumed to be influential in suicide contagion and determine the interrater reliability of the qualitative characteristics abstracted from newspaper stories. A random subset of 151 articles from a database of 1851 newspaper suicide stories published during 1988 through 1996, which were collected as part of a national study in the United States to identify factors associated with the initiation of youth suicide clusters, were evaluated. Using a well-defined content-analysis procedure, the agreement between raters in scoring key concepts of suicide reports from the headline, the pictorial presentation, and the text were evaluated. The results show that while the majority of variables in the content analysis were very reliable, assessed using the kappa statistic, and obtained excellent percentages of agreement, the reliability of complicated constructs, such as sensationalizing, glorifying, or romanticizing the suicide, was comparatively low. The data emphasize that before effective guidelines and responsible suicide reporting can ensue, further explication of suicide story constructs is necessary to ensure the implementation and compliance of responsible reporting on behalf of the media.

  10. Probabilistic risk assessment for a loss of coolant accident in McMaster Nuclear Reactor and application of reliability physics model for modeling human reliability

    NASA Astrophysics Data System (ADS)

    Ha, Taesung

    A probabilistic risk assessment (PRA) was conducted for a loss of coolant accident, (LOCA) in the McMaster Nuclear Reactor (MNR). A level 1 PRA was completed including event sequence modeling, system modeling, and quantification. To support the quantification of the accident sequence identified, data analysis using the Bayesian method and human reliability analysis (HRA) using the accident sequence evaluation procedure (ASEP) approach were performed. Since human performance in research reactors is significantly different from that in power reactors, a time-oriented HRA model (reliability physics model) was applied for the human error probability (HEP) estimation of the core relocation. This model is based on two competing random variables: phenomenological time and performance time. The response surface and direct Monte Carlo simulation with Latin Hypercube sampling were applied for estimating the phenomenological time, whereas the performance time was obtained from interviews with operators. An appropriate probability distribution for the phenomenological time was assigned by statistical goodness-of-fit tests. The human error probability (HEP) for the core relocation was estimated from these two competing quantities: phenomenological time and operators' performance time. The sensitivity of each probability distribution in human reliability estimation was investigated. In order to quantify the uncertainty in the predicted HEPs, a Bayesian approach was selected due to its capability of incorporating uncertainties in model itself and the parameters in that model. The HEP from the current time-oriented model was compared with that from the ASEP approach. Both results were used to evaluate the sensitivity of alternative huinan reliability modeling for the manual core relocation in the LOCA risk model. This exercise demonstrated the applicability of a reliability physics model supplemented with a. Bayesian approach for modeling human reliability and its potential usefulness of quantifying model uncertainty as sensitivity analysis in the PRA model.

  11. Robust hard-solder packaging of conduction cooled laser diode bars

    NASA Astrophysics Data System (ADS)

    Schleuning, David; Griffin, Mike; James, Phillip; McNulty, John; Mendoza, Dan; Morales, John; Nabors, David; Peters, Mike; Zhou, Hailong; Reed, Murray

    2007-02-01

    We present the reliability of high-power laser diodes utilizing hard solder (AuSn) on a conduction-cooled package (HCCP). We present results of 50 W hard-pulse operation at 8xx nm and demonstrate a reliability of MTTF > 27 khrs (90% CL), which is an order of magnitude improvement over traditional packaging. We also present results at 9xx nm with a reliability of MTTF >17 khrs (90% CL) at 75 W. We discuss finite element analysis (FEA) modeling and time dependent temperature measurements combined with experimental life-test data to quantify true hard-pulse operation. We also discuss FEA and measured stress profiles across laser bars comparing soft and hard solder packaging.

  12. Analysis of the reliability and reproducibility of goniometry compared to hand photogrammetry

    PubMed Central

    de Carvalho, Rosana Martins Ferreira; Mazzer, Nilton; Barbieri, Claudio Henrique

    2012-01-01

    Objective: To evaluate the intra- and inter-examiner reliability and reproducibility of goniometry in relation to photogrammetry of hand, comparing the angles of thumb abduction, PIP joint flexion of the II finger and MCP joint flexion of the V finger. Methods: The study included 30 volunteers, who were divided into three groups: one group of 10 physiotherapy students, one group of 10 physiotherapists, and a third group of 10 therapists of the hand. Each examiner performed the measurements on the same hand mold, using the goniometer followed by two photogrammetry software programs; CorelDraw® and ALCimagem®. Results: The results revealed that the groups and the methods proposed presented inter-examiner reliability, generally rated as excellent (ICC 0.998 I.C. 95% 0.995 - 0.999). In the intra-examiner evaluation, an excellent level of reliability was found between the three groups. In the comparison between groups for each angle and each method, no significant differences were found between the groups for most of the measurements. Conclusion: Goniometry and photogrammetry are reliable and reproducible methods for evaluating measurements of the hand. However, due to the lack of similar references, detailed studies are needed to define the normal parameters between the methods in the joints of the hand. Level of Evidence II, Diagnostic Study. PMID:24453594

  13. The work and social adjustment scale: reliability, sensitivity and value.

    PubMed

    Zahra, Daniel; Qureshi, Adam; Henley, William; Taylor, Rod; Quinn, Cath; Pooler, Jill; Hardy, Gillian; Newbold, Alexandra; Byng, Richard

    2014-06-01

    To investigate the psychometric properties of the Work and Social Adjustment Scale (WSAS) as an outcome measure for the Improving Access to Psychological Therapy programme, assessing its value as an addition to the Patient Health (PHQ-9) and Generalised Anxiety Disorder questionnaires (GAD-7). Little research has investigated these properties to date. Reliability and responsiveness to change were assessed using data from 4,835 patients. Principal components analysis was used to determine whether the WSAS measures a factor distinct from the PHQ-9 and GAD-7. The WSAS measures a distinct social functioning factor, has high internal reliability, and is sensitive to treatment effects. The WSAS, PHQ-9 and GAD-7 perform comparably on measures of reliability and sensitivity. The WSAS also measures a distinct social functioning component suggesting it has potential as an additional outcome measure.

  14. [Meta-analysis of group comparison and meta-analysis of reliability generalization of the State-Trait Anxiety Inventory Questionnaire (STAI)].

    PubMed

    Guillén-Riquelme, Alejandro; Buela-Casal, Gualberto

    2014-01-01

    Since its creation the STAI has been cited in more than 14,000 documents, with more than 60 adaptations in different countries. In some adaptations this instrument has no clinical scores. The aim of this work is to determine if the State-Trait Anxiety Inventory (STAI) has higher scores in patients diagnosed with anxiety than in general population. In addition, we want to examine if the internal consistency is adequate in anxious patient samples. We performed a literature search in Tripdatabase, Cochrane, Web of Knowledge, Scopus, PyscINFO and Scholar Google, for documents published between 2008 y 2012. We selected 131 scientific articles to compare between patients diagnosed with anxiety and general population, and 25 for the generalization of reliability. For the analysis we used Cohen's d for means comparisons (random-effects method) and Cronbach's alpha for the reliability generalization (fixed-effects method). In the groups comparision the differences in state anxiety (d=1.39; CI95%: 1.22-1.56) and in the trait anxiety (d=1.74; CI95%:1.56-1.91) were significants. The reliability for patients of some anxiety disorder was between 0.87 and 0.93. So it seems that the STAI is sensitive to the level of anxiety of the individual and reliable for patients with diagnosis of panic attack, specific phobia, social phobia, generalized social phobia, generalized anxiety disorder, post-traumatic stress disorder, obsessive compulsive disorder or acute Stress disorder.

  15. Probabilistic Analysis of Space Shuttle Body Flap Actuator Ball Bearings

    NASA Technical Reports Server (NTRS)

    Oswald, Fred B.; Jett, Timothy R.; Predmore, Roamer E.; Zaretsky, Erin V.

    2007-01-01

    A probabilistic analysis, using the 2-parameter Weibull-Johnson method, was performed on experimental life test data from space shuttle actuator bearings. Experiments were performed on a test rig under simulated conditions to determine the life and failure mechanism of the grease lubricated bearings that support the input shaft of the space shuttle body flap actuators. The failure mechanism was wear that can cause loss of bearing preload. These tests established life and reliability data for both shuttle flight and ground operation. Test data were used to estimate the failure rate and reliability as a function of the number of shuttle missions flown. The Weibull analysis of the test data for a 2-bearing shaft assembly in each body flap actuator established a reliability level of 99.6 percent for a life of 12 missions. A probabilistic system analysis for four shuttles, each of which has four actuators, predicts a single bearing failure in one actuator of one shuttle after 22 missions (a total of 88 missions for a 4-shuttle fleet). This prediction is comparable with actual shuttle flight history in which a single actuator bearing was found to have failed by wear at 20 missions.

  16. Probabilistic Analysis of Space Shuttle Body Flap Actuator Ball Bearings

    NASA Technical Reports Server (NTRS)

    Oswald, Fred B.; Jett, Timothy R.; Predmore, Roamer E.; Zaretsky, Erwin V.

    2008-01-01

    A probabilistic analysis, using the 2-parameter Weibull-Johnson method, was performed on experimental life test data from space shuttle actuator bearings. Experiments were performed on a test rig under simulated conditions to determine the life and failure mechanism of the grease lubricated bearings that support the input shaft of the space shuttle body flap actuators. The failure mechanism was wear that can cause loss of bearing preload. These tests established life and reliability data for both shuttle flight and ground operation. Test data were used to estimate the failure rate and reliability as a function of the number of shuttle missions flown. The Weibull analysis of the test data for the four actuators on one shuttle, each with a 2-bearing shaft assembly, established a reliability level of 96.9 percent for a life of 12 missions. A probabilistic system analysis for four shuttles, each of which has four actuators, predicts a single bearing failure in one actuator of one shuttle after 22 missions (a total of 88 missions for a 4-shuttle fleet). This prediction is comparable with actual shuttle flight history in which a single actuator bearing was found to have failed by wear at 20 missions.

  17. Reliability Practice at NASA Goddard Space Flight Center

    NASA Technical Reports Server (NTRS)

    Pruessner, Paula S.; Li, Ming

    2008-01-01

    This paper describes in brief the Reliability and Maintainability (R&M) Programs performed directly by the reliability branch at Goddard Space Flight Center (GSFC). The mission assurance requirements flow down is explained. GSFC practices for PRA, reliability prediction/fault tree analysis/reliability block diagram, FMEA, part stress and derating analysis, worst case analysis, trend analysis, limit life items are presented. Lessons learned are summarized and recommendations on improvement are identified.

  18. Reliability and validity of the multimedia activity recall in children and adults (MARCA) in people with chronic obstructive pulmonary disease.

    PubMed

    Hunt, Toby; Williams, Marie T; Olds, Tim S

    2013-01-01

    To determine the reliability and validity of the Multimedia Activity Recall for Children and Adults (MARCA) in people with chronic obstructive pulmonary disease (COPD). People with COPD and their carers completed the Multimedia Activity Recall for Children and Adults (MARCA) for four, 24-hour periods (including test-retest of 2 days) while wearing a triaxial accelerometer (Actigraph GT3X+®), a multi-sensor armband (Sensewear Pro3®) and a pedometer (New Lifestyles 1000®). Self reported activity recalls (MARCA) and objective activity monitoring (Accelerometry) were recorded under free-living conditions. 24 couples were included in the analysis (COPD; age 74.4 ± 7.9 yrs, FEV1 54 ± 13% Carer; age 69.6 ± 10.9 yrs, FEV1 99 ± 24%). Not applicable. Test-retest reliability was compared for MARCA activity domains and different energy expenditure zones. Validity was assessed between MARCA-derived physical activity level (in metabolic equivalent of task (MET) per minute), duration of moderate to vigorous physical activity (min) and related data from the objective measurement devices. Analysis included intra-class correlation coefficients (ICC), Bland-Altman analyses, paired t-tests (p) and Spearman's rank correlation coefficients (rs). Reliability between occasions of recall for all activity domains was uniformly high, with test-retest correlations consistently >0.9. Validity correlations were moderate to strong (rs = 0.43-0.80) across all comparisons. The MARCA yields comparable PAL estimates and slightly higher moderate to vigorous physical activity (MVPA) estimates. In older adults with chronic illness, the MARCA is a valid and reliable tool for capturing not only the time and energy expenditure associated with physical and sedentary activities but also information on the types of activities.

  19. Validity and reliability of the abdominal test and evaluation systems tool (ABTEST) to accurately measure abdominal force.

    PubMed

    Glenn, Jordan M; Galey, Madeline; Edwards, Abigail; Rickert, Bradley; Washington, Tyrone A

    2015-07-01

    Ability to generate force from the core musculature is a critical factor for sports and general activities with insufficiencies predisposing individuals to injury. This study evaluated isometric force production as a valid and reliable method of assessing abdominal force using the abdominal test and evaluation systems tool (ABTEST). Secondary analysis estimated 1-repetition maximum on commercially available abdominal machine compared to maximum force and average power on ABTEST system. This study utilized test-retest reliability and comparative analysis for validity. Reliability was measured using test-retest design on ABTEST. Validity was measured via comparison to estimated 1-repetition maximum on a commercially available abdominal device. Participants applied isometric, abdominal force against a transducer and muscular activation was evaluated measuring normalized electromyographic activity at the rectus-abdominus, rectus-femoris, and erector-spinae. Test, re-test force production on ABTEST was significantly correlated (r=0.84; p<0.001). Mean electromyographic activity for the rectus-abdominus (72.93% and 75.66%), rectus-femoris (6.59% and 6.51%), and erector-spinae (6.82% and 5.48%) were observed for trial-1 and trial-2, respectively. Significant correlations for the estimated 1-repetition maximum were found for average power (r=0.70, p=0.002) and maximum force (r=0.72, p<0.001). Data indicate the ABTEST can accurately measure rectus-abdominus force isolated from hip-flexor involvement. Negligible activation of erector-spinae substantiates little subjective effort among participants in the lower back. Results suggest ABTEST is a valid and reliable method of evaluating abdominal force. Copyright © 2014 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  20. A Time-Variant Reliability Model for Copper Bending Pipe under Seawater-Active Corrosion Based on the Stochastic Degradation Process

    PubMed Central

    Li, Mengmeng; Feng, Qiang; Yang, Dezhen

    2018-01-01

    In the degradation process, the randomness and multiplicity of variables are difficult to describe by mathematical models. However, they are common in engineering and cannot be neglected, so it is necessary to study this issue in depth. In this paper, the copper bending pipe in seawater piping systems is taken as the analysis object, and the time-variant reliability is calculated by solving the interference of limit strength and maximum stress. We did degradation experiments and tensile experiments on copper material, and obtained the limit strength at each time. In addition, degradation experiments on copper bending pipe were done and the thickness at each time has been obtained, then the response of maximum stress was calculated by simulation. Further, with the help of one kind of Monte Carlo method we propose, the time-variant reliability of copper bending pipe was calculated based on the stochastic degradation process and interference theory. Compared with traditional methods and verified by maintenance records, the results show that the time-variant reliability model based on the stochastic degradation process proposed in this paper has better applicability in the reliability analysis, and it can be more convenient and accurate to predict the replacement cycle of copper bending pipe under seawater-active corrosion. PMID:29584695

  1. Reliability and validity of a Turkish version of the Global Pelvic Floor Bother Questionnaire.

    PubMed

    Doğan, Hanife; Özengin, Nuriye; Bakar, Yeşim; Duran, Bülent

    2016-10-01

    The aim of this study was to translate the Global Pelvic Floor Bother Questionnaire (GPFBQ) into Turkish and to assess its validity and reliability. The Turkish adaptation of the GPFBQ was created by following the stages of the intercultural adaptation process. A test-retest interval of 1 week was used to assess the reliability, which was examined by the intraclass correlation coefficient. The validity of the GPFBQ was assessed and compared with the Pelvic Floor Distress Inventory-20 (PFDI-20) and the Pelvic Floor Impact Questionnaire-7 (PFIQ-7) using Spearman's rank correlation coefficients. For construct validity, confirmatory factor analysis was performed. A total of 131 women, whose mean age was 46.83 years, were included in the study. The test-retest reliability of the GPFBQ was excellent (0.998, p < 0.0001). The GPFBQ correlated significantly with the PFDI-20 (r = 0.860, p = 0.00) and PFIQ-7 (r = 0.802, p = 0.00). Confirmatory factor analysis was performed to determine construct validity, and it was found that it had four dimensions. The Turkish version of the GPFBQ is a valid and reliable tool for assessing the symptoms of bother and severity in Turkish-speaking women with pelvic floor dysfunction.

  2. Reliable Alignment in Total Knee Arthroplasty by the Use of an iPod-Based Navigation System

    PubMed Central

    Koenen, Paola; Schneider, Marco M.; Fröhlich, Matthias; Driessen, Arne; Bouillon, Bertil; Bäthis, Holger

    2016-01-01

    Axial alignment is one of the main objectives in total knee arthroplasty (TKA). Computer-assisted surgery (CAS) is more accurate regarding limb alignment reconstruction compared to the conventional technique. The aim of this study was to analyse the precision of the innovative navigation system DASH® by Brainlab and to evaluate the reliability of intraoperatively acquired data. A retrospective analysis of 40 patients was performed, who underwent CAS TKA using the iPod-based navigation system DASH. Pre- and postoperative axial alignment were measured on standardized radiographs by two independent observers. These data were compared with the navigation data. Furthermore, interobserver reliability was measured. The duration of surgery was monitored. The mean difference between the preoperative mechanical axis by X-ray and the first intraoperatively measured limb axis by the navigation system was 2.4°. The postoperative X-rays showed a mean difference of 1.3° compared to the final navigation measurement. According to radiographic measurements, 88% of arthroplasties had a postoperative limb axis within ±3°. The mean additional time needed for navigation was 5 minutes. We could prove very good precision for the DASH system, which is comparable to established navigation devices with only negligible expenditure of time compared to conventional TKA. PMID:27313898

  3. Quantification of Pulmonary Fibrosis in a Bleomycin Mouse Model Using Automated Histological Image Analysis.

    PubMed

    Gilhodes, Jean-Claude; Julé, Yvon; Kreuz, Sebastian; Stierstorfer, Birgit; Stiller, Detlef; Wollin, Lutz

    2017-01-01

    Current literature on pulmonary fibrosis induced in animal models highlights the need of an accurate, reliable and reproducible histological quantitative analysis. One of the major limits of histological scoring concerns the fact that it is observer-dependent and consequently subject to variability, which may preclude comparative studies between different laboratories. To achieve a reliable and observer-independent quantification of lung fibrosis we developed an automated software histological image analysis performed from digital image of entire lung sections. This automated analysis was compared to standard evaluation methods with regard to its validation as an end-point measure of fibrosis. Lung fibrosis was induced in mice by intratracheal administration of bleomycin (BLM) at 0.25, 0.5, 0.75 and 1 mg/kg. A detailed characterization of BLM-induced fibrosis was performed 14 days after BLM administration using lung function testing, micro-computed tomography and Ashcroft scoring analysis. Quantification of fibrosis by automated analysis was assessed based on pulmonary tissue density measured from thousands of micro-tiles processed from digital images of entire lung sections. Prior to analysis, large bronchi and vessels were manually excluded from the original images. Measurement of fibrosis has been expressed by two indexes: the mean pulmonary tissue density and the high pulmonary tissue density frequency. We showed that tissue density indexes gave access to a very accurate and reliable quantification of morphological changes induced by BLM even for the lowest concentration used (0.25 mg/kg). A reconstructed 2D-image of the entire lung section at high resolution (3.6 μm/pixel) has been performed from tissue density values allowing the visualization of their distribution throughout fibrotic and non-fibrotic regions. A significant correlation (p<0.0001) was found between automated analysis and the above standard evaluation methods. This correlation establishes automated analysis as a novel end-point measure of BLM-induced lung fibrosis in mice, which will be very valuable for future preclinical drug explorations.

  4. Quantification of Pulmonary Fibrosis in a Bleomycin Mouse Model Using Automated Histological Image Analysis

    PubMed Central

    Gilhodes, Jean-Claude; Kreuz, Sebastian; Stierstorfer, Birgit; Stiller, Detlef; Wollin, Lutz

    2017-01-01

    Current literature on pulmonary fibrosis induced in animal models highlights the need of an accurate, reliable and reproducible histological quantitative analysis. One of the major limits of histological scoring concerns the fact that it is observer-dependent and consequently subject to variability, which may preclude comparative studies between different laboratories. To achieve a reliable and observer-independent quantification of lung fibrosis we developed an automated software histological image analysis performed from digital image of entire lung sections. This automated analysis was compared to standard evaluation methods with regard to its validation as an end-point measure of fibrosis. Lung fibrosis was induced in mice by intratracheal administration of bleomycin (BLM) at 0.25, 0.5, 0.75 and 1 mg/kg. A detailed characterization of BLM-induced fibrosis was performed 14 days after BLM administration using lung function testing, micro-computed tomography and Ashcroft scoring analysis. Quantification of fibrosis by automated analysis was assessed based on pulmonary tissue density measured from thousands of micro-tiles processed from digital images of entire lung sections. Prior to analysis, large bronchi and vessels were manually excluded from the original images. Measurement of fibrosis has been expressed by two indexes: the mean pulmonary tissue density and the high pulmonary tissue density frequency. We showed that tissue density indexes gave access to a very accurate and reliable quantification of morphological changes induced by BLM even for the lowest concentration used (0.25 mg/kg). A reconstructed 2D-image of the entire lung section at high resolution (3.6 μm/pixel) has been performed from tissue density values allowing the visualization of their distribution throughout fibrotic and non-fibrotic regions. A significant correlation (p<0.0001) was found between automated analysis and the above standard evaluation methods. This correlation establishes automated analysis as a novel end-point measure of BLM-induced lung fibrosis in mice, which will be very valuable for future preclinical drug explorations. PMID:28107543

  5. A reliability design method for a lithium-ion battery pack considering the thermal disequilibrium in electric vehicles

    NASA Astrophysics Data System (ADS)

    Xia, Quan; Wang, Zili; Ren, Yi; Sun, Bo; Yang, Dezhen; Feng, Qiang

    2018-05-01

    With the rapid development of lithium-ion battery technology in the electric vehicle (EV) industry, the lifetime of the battery cell increases substantially; however, the reliability of the battery pack is still inadequate. Because of the complexity of the battery pack, a reliability design method for a lithium-ion battery pack considering the thermal disequilibrium is proposed in this paper based on cell redundancy. Based on this method, a three-dimensional electric-thermal-flow-coupled model, a stochastic degradation model of cells under field dynamic conditions and a multi-state system reliability model of a battery pack are established. The relationships between the multi-physics coupling model, the degradation model and the system reliability model are first constructed to analyze the reliability of the battery pack and followed by analysis examples with different redundancy strategies. By comparing the reliability of battery packs of different redundant cell numbers and configurations, several conclusions for the redundancy strategy are obtained. More notably, the reliability does not monotonically increase with the number of redundant cells for the thermal disequilibrium effects. In this work, the reliability of a 6 × 5 parallel-series configuration is the optimal system structure. In addition, the effect of the cell arrangement and cooling conditions are investigated.

  6. Does Changing Examiner Stations During UK Postgraduate Surgery Objective Structured Clinical Examinations Influence Examination Reliability and Candidates' Scores?

    PubMed

    Brennan, Peter A; Croke, David T; Reed, Malcolm; Smith, Lee; Munro, Euan; Foulkes, John; Arnett, Richard

    2016-01-01

    Objective structured clinical examinations (OSCE) are widely used for summative assessment in surgery. Despite standardizing these as much as possible, variation, including examiner scoring, can occur which may affect reliability. In study of a high-stakes UK postgraduate surgical OSCE, we investigated whether examiners changing stations once during a long examining day affected marking, reliability, and overall candidates' scores compared with examiners who examined the same scenario all day. An observational study of 18,262 examiner-candidate interactions from the UK Membership of the Royal College of Surgeons examination was carried at 3 Surgical Colleges across the United Kingdom. Scores between examiners were compared using analysis of variance. Examination reliability was assessed with Cronbach's alpha, and the comparative distribution of total candidates' scores for each day was evaluated using t-tests of unit-weighted z scores. A significant difference was found in absolute scores differences awarded in the morning and afternoon sessions between examiners who changed stations at lunchtime and those who did not (p < 0.001). No significant differences were found for the main effects of either broad content area (p = 0.290) or station content area (p = 0.450). The reliability of each day was not affected by examiner switching (p = 0.280). Overall, no difference was found in z-score distribution of total candidate scores and categories of examiner switching. This large study has found that although the range of marks awarded varied when examiners change OSCE stations, examination reliability and the likely candidate outcome were not affected. These results may have implications for examination design and examiner experience in surgical OSCEs and beyond. Copyright © 2016 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.

  7. Reliability of Two Smartphone Applications for Radiographic Measurements of Hallux Valgus Angles.

    PubMed

    Mattos E Dinato, Mauro Cesar; Freitas, Marcio de Faria; Milano, Cristiano; Valloto, Elcio; Ninomiya, André Felipe; Pagnano, Rodrigo Gonçalves

    The objective of the present study was to assess the reliability of 2 smartphone applications compared with the traditional goniometer technique for measurement of radiographic angles in hallux valgus and the time required for analysis with the different methods. The radiographs of 31 patients (52 feet) with a diagnosis of hallux valgus were analyzed. Four observers, 2 with >10 years' experience in foot and ankle surgery and 2 in-training surgeons, measured the hallux valgus angle and intermetatarsal angle using a manual goniometer technique and 2 smartphone applications (Hallux Angles and iPinPoint). The interobserver and intermethod reliability were estimated using intraclass correlation coefficients (ICCs), and the time required for measurement of the angles among the 3 methods was compared using the Friedman test. A very good or good interobserver reliability was found among the 4 observers measuring the hallux valgus angle and intermetatarsal angle using the goniometer (ICC 0.913 and 0.821, respectively) and iPinPoint (ICC 0.866 and 0.638, respectively). Using the Hallux Angles application, a very good interobserver reliability was found for measurements of the hallux valgus angle (ICC 0.962) and intermetatarsal angle (ICC 0.935) only among the more experienced observers. The time required for the measurements was significantly shorter for the measurements using both smartphone applications compared with the goniometer method. One smartphone application (iPinPoint) was reliable for measurements of the hallux valgus angles by either experienced or nonexperienced observers. The use of these tools might save time in the evaluation of radiographic angles in the hallux valgus. Copyright © 2016 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  8. Observations on the predictive value of short-term stake tests

    Treesearch

    Stan Lebow; Bessie Woodward; Patricia Lebow

    2008-01-01

    This paper compares average ratings of test stakes after 3, 4, 5, and 7 years exposure to their subsequent ratings after 11 years. Average ratings from over 200 treatment groups exposed in plots in southern Mississippi were compared to average ratings of a reference preservative. The analysis revealed that even perfect ratings after three years were not a reliable...

  9. Reliability and validity of abbreviated surveys derived from the National Eye Institute Visual Function Questionnaire: The Study of Osteoporotic Fractures

    PubMed Central

    Gergana, Kodjebacheva; Coleman, Anne L.; Ensrud, Kristine E.; Cauley, Jane A.; Yu, Fei; Stone, Katie L.; Pedula, Kathryn L.; Hochberg, Marc C.; Mangione, Carol M.

    2010-01-01

    Purpose To test the reliability and validity of questionnaires shortened from the National Eye Institute 25-item Vision Function Questionnaire (NEI VFQ-9 and NEI VFQ-8). Design A cross-sectional multi-center cohort study. Methods Reliability was assessed by Cronbach alpha coefficients. Validity was evaluated by studying the association of vision-targeted quality-of-life composite scores with objective visual function measurements. Study population: A total of 5,482 women between the ages of 65 and 100 years participated in the Year-10 clinic visit in the Study of Osteoporotic Fractures (SOF). A total of 3,631 women with complete data were included in the visual acuity (VA) and visual field (VF) analysis of the NEI VFQ-9, which is defined for those who care to drive. and 5,311 in the analysis of the NEI VFQ-8. To assess differences in prevalent eye diseases, which were ascertained for a random sample of SOF participants, 853 and 1,237 women were included in the NEI VFQ-9 and the NEI VFQ-8 analyses, respectively. Results Cronbach alpha coefficient for the NEI VFQ-9 scale was 0.83 and that of the NEI VFQ-8 was 0.84. Using both questionnaires, women with VA worse than 20/40 had lower composite scores compared to those with VA 20/40 or better (p<0.001). Participants with mild, moderate, and severe binocular VF loss had lower composite scores compared to those with no binocular VF loss (p<0.001).Compared to women without chronic eye diseases in both eyes, women with at least one chronic eye disease in at least one eye had lower composite scores. Conclusions Both questionnaires showed high reliability across items and validity with respect to clinical markers of eye disease Future research should compare the properties of these shortened surveys to those of the NEI VFQ-25. PMID:20103058

  10. Comparative Validity and Reproducibility Study of Various Landmark-Oriented Reference Planes in 3-Dimensional Computed Tomographic Analysis for Patients Receiving Orthognathic Surgery

    PubMed Central

    Lin, Hsiu-Hsia; Chuang, Ya-Fang; Weng, Jing-Ling; Lo, Lun-Jou

    2015-01-01

    Background Three-dimensional computed tomographic imaging has become popular in clinical evaluation, treatment planning, surgical simulation, and outcome assessment for maxillofacial intervention. The purposes of this study were to investigate whether there is any correlation among landmark-based horizontal reference planes and to validate the reproducibility and reliability of landmark identification. Materials and Methods Preoperative and postoperative cone-beam computed tomographic images of patients who had undergone orthognathic surgery were collected. Landmark-oriented reference planes including the Frankfort horizontal plane (FHP) and the lateral semicircular canal plane (LSP) were established. Four FHPs were defined by selecting 3 points from the orbitale, porion, or midpoint of paired points. The LSP passed through both the lateral semicircular canal points and nasion. The distances between the maxillary or mandibular teeth and the reference planes were measured, and the differences between the 2 sides were calculated and compared. The precision in locating the landmarks was evaluated by performing repeated tests, and the intraobserver reproducibility and interobserver reliability were assessed. Results A total of 30 patients with facial deformity and malocclusion—10 patients with facial symmetry, 10 patients with facial asymmetry, and 10 patients with cleft lip and palate—were recruited. Comparing the differences among the 5 reference planes showed no statistically significant difference among all patient groups. Regarding intraobserver reproducibility, the mean differences in the 3 coordinates varied from 0 to 0.35 mm, with correlation coefficients between 0.96 and 1.0, showing high correlation between repeated tests. Regarding interobserver reliability, the mean differences among the 3 coordinates varied from 0 to 0.47 mm, with correlation coefficients between 0.88 and 1.0, exhibiting high correlation between the different examiners. Conclusions The 5 horizontal reference planes were reliable and comparable for 3D craniomaxillofacial analysis. These reference planes were useful in standardizing the orientation of 3D skull models. PMID:25668209

  11. Comparative validity and reproducibility study of various landmark-oriented reference planes in 3-dimensional computed tomographic analysis for patients receiving orthognathic surgery.

    PubMed

    Lin, Hsiu-Hsia; Chuang, Ya-Fang; Weng, Jing-Ling; Lo, Lun-Jou

    2015-01-01

    Three-dimensional computed tomographic imaging has become popular in clinical evaluation, treatment planning, surgical simulation, and outcome assessment for maxillofacial intervention. The purposes of this study were to investigate whether there is any correlation among landmark-based horizontal reference planes and to validate the reproducibility and reliability of landmark identification. Preoperative and postoperative cone-beam computed tomographic images of patients who had undergone orthognathic surgery were collected. Landmark-oriented reference planes including the Frankfort horizontal plane (FHP) and the lateral semicircular canal plane (LSP) were established. Four FHPs were defined by selecting 3 points from the orbitale, porion, or midpoint of paired points. The LSP passed through both the lateral semicircular canal points and nasion. The distances between the maxillary or mandibular teeth and the reference planes were measured, and the differences between the 2 sides were calculated and compared. The precision in locating the landmarks was evaluated by performing repeated tests, and the intraobserver reproducibility and interobserver reliability were assessed. A total of 30 patients with facial deformity and malocclusion--10 patients with facial symmetry, 10 patients with facial asymmetry, and 10 patients with cleft lip and palate--were recruited. Comparing the differences among the 5 reference planes showed no statistically significant difference among all patient groups. Regarding intraobserver reproducibility, the mean differences in the 3 coordinates varied from 0 to 0.35 mm, with correlation coefficients between 0.96 and 1.0, showing high correlation between repeated tests. Regarding interobserver reliability, the mean differences among the 3 coordinates varied from 0 to 0.47 mm, with correlation coefficients between 0.88 and 1.0, exhibiting high correlation between the different examiners. The 5 horizontal reference planes were reliable and comparable for 3D craniomaxillofacial analysis. These reference planes were useful in standardizing the orientation of 3D skull models.

  12. Validity and reliability of smartphone magnetometer-based goniometer evaluation of shoulder abduction--A pilot study.

    PubMed

    Johnson, Linda B; Sumner, Sean; Duong, Tina; Yan, Posu; Bajcsy, Ruzena; Abresch, R Ted; de Bie, Evan; Han, Jay J

    2015-12-01

    Goniometers are commonly used by physical therapists to measure range-of-motion (ROM) in the musculoskeletal system. These measurements are used to assist in diagnosis and to help monitor treatment efficacy. With newly emerging technologies, smartphone-based applications are being explored for measuring joint angles and movement. This pilot study investigates the intra- and inter-rater reliability as well as concurrent validity of a newly-developed smartphone magnetometer-based goniometer (MG) application for measuring passive shoulder abduction in both sitting and supine positions, and compare against the traditional universal goniometer (UG). This is a comparative study with repeated measurement design. Three physical therapists utilized both the smartphone MG and a traditional UG to measure various angles of passive shoulder abduction in a healthy subject, whose shoulder was positioned in eight different positions with pre-determined degree of abduction while seated or supine. Each therapist was blinded to the measured angles. Concordance correlation coefficients (CCCs), Bland-Altman plotting methods, and Analysis of Variance (ANOVA) were used for statistical analyses. Both traditional UG and smartphone MG were reliable in repeated measures of standardized joint angle positions (average CCC > 0.997) with similar variability in both measurement tools (standard deviation (SD) ± 4°). Agreement between the UG and MG measurements was greater than 0.99 in all positions. Our results show that the smartphone MG has equivalent reliability compared to the traditional UG when measuring passive shoulder abduction ROM. With concordant measures and comparable reliability to the UG, the newly developed MG application shows potential as a useful tool to assess joint angles. Published by Elsevier Ltd.

  13. [Comparative study of the population structure and population assignment of sockeye salmon Oncorhynchus nerka from West Kamchatka based on RAPD-PCR and microsatellite polymorphism].

    PubMed

    Zelenina, D A; Khrustaleva, A M; Volkov, A A

    2006-05-01

    Using two types of molecular markers, a comparative analysis of the population structure of sockeye salmon from West Kamchatka as well as population assignment of each individual fish were carried out. The values of a RAPD-PCR-based population assignment test (94-100%) were somewhat higher than those based on microsatellite data (74-84%). However, these results seem quite satisfactory because of high polymorphism of the microsatellite loci examined. The UPGMA dendrograms of genetic similarity of three largest spawning populations, constructed using each of the methods, were highly reliable, which was demonstrated by high bootstrap indices (100% in the case of RAPD-PCR; 84 and 100%, in the case of microsatellite analysis), though the resultant trees differed from one another. The different topology of the trees, in our view, is explained by the fact that the employed methods explored different parts of the genome; hence, the obtained results, albeit valid, may not correlate. Thus, to enhance reliability of the results, several methods of analysis should be used concurrently.

  14. The Comparative Effectiveness of Different Item Analysis Techniques in Increasing Change Score Reliability.

    ERIC Educational Resources Information Center

    Crocker, Linda M.; Mehrens, William A.

    Four new methods of item analysis were used to select subsets of items which would yield measures of attitude change. The sample consisted of 263 students at Michigan State University who were tested on the Inventory of Beliefs as freshmen and retested on the same instrument as juniors. Item change scores and total change scores were computed for…

  15. High-reliability gas-turbine combined-cycle development program: Phase II. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hecht, K.G.; Sanderson, R.A.; Smith, M.J.

    This three-volume report presents the results of Phase II of the multiphase EPRI-sponsored High-Reliability Gas Turbine Combined-Cycle Development Program whose goal is to achieve a highly reliable gas turbine combined-cycle power plant, available by the mid-1980s, which would be an economically attractive baseload generation alternative for the electric utility industry. The Phase II program objective was to prepare the preliminary design of this power plant. This volume presents information of the reliability, availability, and maintainability (RAM) analysis of a representative plant and the preliminary design of the gas turbine, the gas turbine ancillaries, and the balance of plant including themore » steam turbine generator. To achieve the program goals, a gas turbine was incorporated which combined proven reliability characteristics with improved performance features. This gas turbine, designated the V84.3, is the result of a cooperative effort between Kraftwerk Union AG and United Technologies Corporation. Gas turbines of similar design operating in Europe under baseload conditions have demonstrated mean time between failures in excess of 40,000 hours. The reliability characteristics of the gas turbine ancillaries and balance-of-plant equipment were improved through system simplification and component redundancy and by selection of component with inherent high reliability. A digital control system was included with logic, communications, sensor redundancy, and mandual backup. An independent condition monitoring and diagnostic system was also included. Program results provide the preliminary design of a gas turbine combined-cycle baseload power plant. This power plant has a predicted mean time between failure of nearly twice the 3000-hour EPRI goal. The cost of added reliability features is offset by improved performance, which results in a comparable specific cost and an 8% lower cost of electricity compared to present market offerings.« less

  16. Scaling Impacts in Life Support Architecture and Technology Selection

    NASA Technical Reports Server (NTRS)

    Lange, Kevin

    2016-01-01

    For long-duration space missions outside of Earth orbit, reliability considerations will drive higher levels of redundancy and/or on-board spares for life support equipment. Component scaling will be a critical element in minimizing overall launch mass while maintaining an acceptable level of system reliability. Building on an earlier reliability study (AIAA 2012-3491), this paper considers the impact of alternative scaling approaches, including the design of technology assemblies and their individual components to maximum, nominal, survival, or other fractional requirements. The optimal level of life support system closure is evaluated for deep-space missions of varying duration using equivalent system mass (ESM) as the comparative basis. Reliability impacts are included in ESM by estimating the number of component spares required to meet a target system reliability. Common cause failures are included in the analysis. ISS and ISS-derived life support technologies are considered along with selected alternatives. This study focusses on minimizing launch mass, which may be enabling for deep-space missions.

  17. Distinct Neural-Functional Effects of Treatments With Selective Serotonin Reuptake Inhibitors, Electroconvulsive Therapy, and Transcranial Magnetic Stimulation and Their Relations to Regional Brain Function in Major Depression: A Meta-analysis.

    PubMed

    Chau, David T; Fogelman, Phoebe; Nordanskog, Pia; Drevets, Wayne C; Hamilton, J Paul

    2017-05-01

    Functional neuroimaging studies have examined the neural substrates of treatments for major depressive disorder (MDD). Low sample size and methodological heterogeneity, however, undermine the generalizability of findings from individual studies. We conducted a meta-analysis to identify reliable neural changes resulting from different modes of treatment for MDD and compared them with each other and with reliable neural functional abnormalities observed in depressed versus control samples. We conducted a meta-analysis of studies reporting changes in brain activity (e.g., as indexed by positron emission tomography) following treatments with selective serotonin reuptake inhibitors (SSRIs), electroconvulsive therapy (ECT), or transcranial magnetic stimulation. Additionally, we examined the statistical reliability of overlap among thresholded meta-analytic SSRI, ECT, and transcranial magnetic stimulation maps as well as a map of abnormal neural function in MDD. Our meta-analysis revealed that 1) SSRIs decrease activity in the anterior insula, 2) ECT decreases activity in central nodes of the default mode network, 3) transcranial magnetic stimulation does not result in reliable neural changes, and 4) regional effects of these modes of treatment do not significantly overlap with each other or with regions showing reliable functional abnormality in MDD. SSRIs and ECT produce neurally distinct effects relative to each other and to the functional abnormalities implicated in depression. These treatments therefore may exert antidepressant effects by diminishing neural functions not implicated in depression but that nonetheless impact mood. We discuss how the distinct neural changes resulting from SSRIs and ECT can account for both treatment effects and side effects from these therapies as well as how to individualize these treatments. Copyright © 2017 Society of Biological Psychiatry. Published by Elsevier Inc. All rights reserved.

  18. Technique for Early Reliability Prediction of Software Components Using Behaviour Models

    PubMed Central

    Ali, Awad; N. A. Jawawi, Dayang; Adham Isa, Mohd; Imran Babar, Muhammad

    2016-01-01

    Behaviour models are the most commonly used input for predicting the reliability of a software system at the early design stage. A component behaviour model reveals the structure and behaviour of the component during the execution of system-level functionalities. There are various challenges related to component reliability prediction at the early design stage based on behaviour models. For example, most of the current reliability techniques do not provide fine-grained sequential behaviour models of individual components and fail to consider the loop entry and exit points in the reliability computation. Moreover, some of the current techniques do not tackle the problem of operational data unavailability and the lack of analysis results that can be valuable for software architects at the early design stage. This paper proposes a reliability prediction technique that, pragmatically, synthesizes system behaviour in the form of a state machine, given a set of scenarios and corresponding constraints as input. The state machine is utilized as a base for generating the component-relevant operational data. The state machine is also used as a source for identifying the nodes and edges of a component probabilistic dependency graph (CPDG). Based on the CPDG, a stack-based algorithm is used to compute the reliability. The proposed technique is evaluated by a comparison with existing techniques and the application of sensitivity analysis to a robotic wheelchair system as a case study. The results indicate that the proposed technique is more relevant at the early design stage compared to existing works, and can provide a more realistic and meaningful prediction. PMID:27668748

  19. Design and Analysis of a Flexible, Reliable Deep Space Life Support System

    NASA Technical Reports Server (NTRS)

    Jones, Harry W.

    2012-01-01

    This report describes a flexible, reliable, deep space life support system design approach that uses either storage or recycling or both together. The design goal is to provide the needed life support performance with the required ultra reliability for the minimum Equivalent System Mass (ESM). Recycling life support systems used with multiple redundancy can have sufficient reliability for deep space missions but they usually do not save mass compared to mixed storage and recycling systems. The best deep space life support system design uses water recycling with sufficient water storage to prevent loss of crew if recycling fails. Since the amount of water needed for crew survival is a small part of the total water requirement, the required amount of stored water is significantly less than the total to be consumed. Water recycling with water, oxygen, and carbon dioxide removal material storage can achieve the high reliability of full storage systems with only half the mass of full storage and with less mass than the highly redundant recycling systems needed to achieve acceptable reliability. Improved recycling systems with lower mass and higher reliability could perform better than systems using storage.

  20. Lifetime Reliability Prediction of Ceramic Structures Under Transient Thermomechanical Loads

    NASA Technical Reports Server (NTRS)

    Nemeth, Noel N.; Jadaan, Osama J.; Gyekenyesi, John P.

    2005-01-01

    An analytical methodology is developed to predict the probability of survival (reliability) of ceramic components subjected to harsh thermomechanical loads that can vary with time (transient reliability analysis). This capability enables more accurate prediction of ceramic component integrity against fracture in situations such as turbine startup and shutdown, operational vibrations, atmospheric reentry, or other rapid heating or cooling situations (thermal shock). The transient reliability analysis methodology developed herein incorporates the following features: fast-fracture transient analysis (reliability analysis without slow crack growth, SCG); transient analysis with SCG (reliability analysis with time-dependent damage due to SCG); a computationally efficient algorithm to compute the reliability for components subjected to repeated transient loading (block loading); cyclic fatigue modeling using a combined SCG and Walker fatigue law; proof testing for transient loads; and Weibull and fatigue parameters that are allowed to vary with temperature or time. Component-to-component variation in strength (stochastic strength response) is accounted for with the Weibull distribution, and either the principle of independent action or the Batdorf theory is used to predict the effect of multiaxial stresses on reliability. The reliability analysis can be performed either as a function of the component surface (for surface-distributed flaws) or component volume (for volume-distributed flaws). The transient reliability analysis capability has been added to the NASA CARES/ Life (Ceramic Analysis and Reliability Evaluation of Structures/Life) code. CARES/Life was also updated to interface with commercially available finite element analysis software, such as ANSYS, when used to model the effects of transient load histories. Examples are provided to demonstrate the features of the methodology as implemented in the CARES/Life program.

  1. Development and validation of the Simulation Learning Effectiveness Inventory.

    PubMed

    Chen, Shiah-Lian; Huang, Tsai-Wei; Liao, I-Chen; Liu, Chienchi

    2015-10-01

    To develop and psychometrically test the Simulation Learning Effectiveness Inventory. High-fidelity simulation helps students develop clinical skills and competencies. Yet, reliable instruments measuring learning outcomes are scant. A descriptive cross-sectional survey was used to validate psychometric properties of the instrument measuring students' perception of stimulation learning effectiveness. A purposive sample of 505 nursing students who had taken simulation courses was recruited from a department of nursing of a university in central Taiwan from January 2010-June 2010. The study was conducted in two phases. In Phase I, question items were developed based on the literature review and the preliminary psychometric properties of the inventory were evaluated using exploratory factor analysis. Phase II was conducted to evaluate the reliability and validity of the finalized inventory using confirmatory factor analysis. The results of exploratory and confirmatory factor analyses revealed the instrument was composed of seven factors, named course arrangement, equipment resource, debriefing, clinical ability, problem-solving, confidence and collaboration. A further second-order analysis showed comparable fits between a three second-order factor (preparation, process and outcome) and the seven first-order factor models. Internal consistency was supported by adequate Cronbach's alphas and composite reliability. Convergent and discriminant validities were also supported by confirmatory factor analysis. The study provides evidence that the Simulation Learning Effectiveness Inventory is reliable and valid for measuring student perception of learning effectiveness. The instrument is helpful in building the evidence-based knowledge of the effect of simulation teaching on students' learning outcomes. © 2015 John Wiley & Sons Ltd.

  2. Fatigue Lifespan of Engine Box Influenced by Fan Blade Out

    NASA Astrophysics Data System (ADS)

    Qiu, Ju; Shi, Jingwei; Su, Huaizhong; Zhang, Jinling; Feng, Juan; Shi, Qian; Tian, Xiaoyu

    2017-11-01

    This provides precious experience and reliable reference data for future design. This paper introduces the analysis process of Fan-blade-out, and considers the effect of windmill load on the fatigue lifespan of the case. According to Extended Operations (ETOPS) in the airworthiness regulations, the fatigue crack of it is analyzed by the unbalanced rotor load, during FBO. Compared with the lifespan in normal work of the engine, this research provides valuable design experience and reliable reference data for the case design in the near future.

  3. Reliability and Failure Modes of Solid-State Lighting Electrical Drivers Subjected to Accelerated Aging

    DOE PAGES

    Lall, Pradeep; Sakalaukus, Peter; Davis, Lynn

    2015-02-19

    An investigation of an off-the-shelf solid-state lighting device with the primary focus on the accompanied light-emitting diode (LED) electrical driver (ED) has been conducted. A set of 10 EDs were exposed to temperature humidity life testing of 85% RH and 85 C (85/85) without an electrical bias per the JEDEC standard JESD22-A101C in order to accelerate the ingress of moisture into the aluminum electrolytic capacitor (AEC) and the EDs in order to assess the reliability of the LED drivers for harsh environment applications. The capacitance and equivalent series resistance for each AEC inside the ED were measured using a handheldmore » LCR meter as possible leading indications of failure. The photometric quantities of a single pristine light engine were monitored in order to investigate the interaction between the light engine and the EDs. These parameters were used in assessing the overall reliability of the EDs. In addition, a comparative analysis has been conducted between the 85/85 accelerated test data and a previously published high-temperature storage life accelerated test of 135°C. The results of the 85/85 acceleration test and the comparative analysis are presented in this paper.« less

  4. Design and validation of a comprehensive fecal incontinence questionnaire.

    PubMed

    Macmillan, Alexandra K; Merrie, Arend E H; Marshall, Roger J; Parry, Bryan R

    2008-10-01

    Fecal incontinence can have a profound effect on quality of life. Its prevalence remains uncertain because of stigma, lack of consistent definition, and dearth of validated measures. This study was designed to develop a valid clinical and epidemiologic questionnaire, building on current literature and expertise. Patients and experts undertook face validity testing. Construct validity, criterion validity, and test-retest reliability was undertaken. Construct validity comprised factor analysis and internal consistency of the quality of life scale. The validity of known groups was tested against 77 control subjects by using regression models. Questionnaire results were compared with a stool diary for criterion validity. Test-retest reliability was calculated from repeated questionnaire completion. The questionnaire achieved good face validity. It was completed by 104 patients. The quality of life scale had four underlying traits (factor analysis) and high internal consistency (overall Cronbach alpha = 0.97). Patients and control subjects answered the questionnaire significantly differently (P < 0.01) in known-groups validity testing. Criterion validity assessment found mean differences close to zero. Median reliability for the whole questionnaire was 0.79 (range, 0.35-1). This questionnaire compares favorably with other available instruments, although the interpretation of stool consistency requires further research. Its sensitivity to treatment still needs to be investigated.

  5. Toward reliable biomarker signatures in the age of liquid biopsies - how to standardize the small RNA-Seq workflow

    PubMed Central

    Buschmann, Dominik; Haberberger, Anna; Kirchner, Benedikt; Spornraft, Melanie; Riedmaier, Irmgard; Schelling, Gustav; Pfaffl, Michael W.

    2016-01-01

    Small RNA-Seq has emerged as a powerful tool in transcriptomics, gene expression profiling and biomarker discovery. Sequencing cell-free nucleic acids, particularly microRNA (miRNA), from liquid biopsies additionally provides exciting possibilities for molecular diagnostics, and might help establish disease-specific biomarker signatures. The complexity of the small RNA-Seq workflow, however, bears challenges and biases that researchers need to be aware of in order to generate high-quality data. Rigorous standardization and extensive validation are required to guarantee reliability, reproducibility and comparability of research findings. Hypotheses based on flawed experimental conditions can be inconsistent and even misleading. Comparable to the well-established MIQE guidelines for qPCR experiments, this work aims at establishing guidelines for experimental design and pre-analytical sample processing, standardization of library preparation and sequencing reactions, as well as facilitating data analysis. We highlight bottlenecks in small RNA-Seq experiments, point out the importance of stringent quality control and validation, and provide a primer for differential expression analysis and biomarker discovery. Following our recommendations will encourage better sequencing practice, increase experimental transparency and lead to more reproducible small RNA-Seq results. This will ultimately enhance the validity of biomarker signatures, and allow reliable and robust clinical predictions. PMID:27317696

  6. Time-Variant Reliability Analysis for Rubber O-Ring Seal Considering Both Material Degradation and Random Load

    PubMed Central

    Liao, Baopeng; Yan, Meichen; Zhang, Weifang; Zhou, Kun

    2017-01-01

    Due to the increase in working hours, the reliability of rubber O-ring seals used in hydraulic systems of transfer machines will change. While traditional methods can only analyze one of the material properties or seal properties, the failure of the O-ring is caused by these two factors together. In this paper, two factors are mainly analyzed: the degradation of material properties and load randomization by processing technology. Firstly, the two factors are defined in terms of material failure and seal failure, before the experimental methods of rubber materials are studied. Following this, the time-variant material properties through experiments and load distribution by monitoring the processing can be obtained. Thirdly, compressive stress and contact stress have been calculated, which was combined with the reliability model to acquire the time-variant reliability for the O-ring. Finally, the life prediction and effect of oil pressure were discussed, then compared with the actual situation. The results show a lifetime of 12 months for the O-ring calculated in this paper, and compared with the replacement records from the maintenance workshop, the result is credible. PMID:29053597

  7. An experimental evaluation of software redundancy as a strategy for improving reliability

    NASA Technical Reports Server (NTRS)

    Eckhardt, Dave E., Jr.; Caglayan, Alper K.; Knight, John C.; Lee, Larry D.; Mcallister, David F.; Vouk, Mladen A.; Kelly, John P. J.

    1990-01-01

    The strategy of using multiple versions of independently developed software as a means to tolerate residual software design faults is suggested by the success of hardware redundancy for tolerating hardware failures. Although, as generally accepted, the independence of hardware failures resulting from physical wearout can lead to substantial increases in reliability for redundant hardware structures, a similar conclusion is not immediate for software. The degree to which design faults are manifested as independent failures determines the effectiveness of redundancy as a method for improving software reliability. Interest in multi-version software centers on whether it provides an adequate measure of increased reliability to warrant its use in critical applications. The effectiveness of multi-version software is studied by comparing estimates of the failure probabilities of these systems with the failure probabilities of single versions. The estimates are obtained under a model of dependent failures and compared with estimates obtained when failures are assumed to be independent. The experimental results are based on twenty versions of an aerospace application developed and certified by sixty programmers from four universities. Descriptions of the application, development and certification processes, and operational evaluation are given together with an analysis of the twenty versions.

  8. A Methodology for the Development of a Reliability Database for an Advanced Reactor Probabilistic Risk Assessment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Grabaskas, Dave; Brunett, Acacia J.; Bucknor, Matthew

    GE Hitachi Nuclear Energy (GEH) and Argonne National Laboratory are currently engaged in a joint effort to modernize and develop probabilistic risk assessment (PRA) techniques for advanced non-light water reactors. At a high level the primary outcome of this project will be the development of next-generation PRA methodologies that will enable risk-informed prioritization of safety- and reliability-focused research and development, while also identifying gaps that may be resolved through additional research. A subset of this effort is the development of a reliability database (RDB) methodology to determine applicable reliability data for inclusion in the quantification of the PRA. The RDBmore » method developed during this project seeks to satisfy the requirements of the Data Analysis element of the ASME/ANS Non-LWR PRA standard. The RDB methodology utilizes a relevancy test to examine reliability data and determine whether it is appropriate to include as part of the reliability database for the PRA. The relevancy test compares three component properties to establish the level of similarity to components examined as part of the PRA. These properties include the component function, the component failure modes, and the environment/boundary conditions of the component. The relevancy test is used to gauge the quality of data found in a variety of sources, such as advanced reactor-specific databases, non-advanced reactor nuclear databases, and non-nuclear databases. The RDB also establishes the integration of expert judgment or separate reliability analysis with past reliability data. This paper provides details on the RDB methodology, and includes an example application of the RDB methodology for determining the reliability of the intermediate heat exchanger of a sodium fast reactor. The example explores a variety of reliability data sources, and assesses their applicability for the PRA of interest through the use of the relevancy test.« less

  9. Alcohol, caffeine, and nicotine consumption in adolescents: hair analysis versus self-report.

    PubMed

    Bertol, Elisabetta; Vaiano, Fabio; Boscolo-Berto, Rafael; Fioravanti, Alessia; Palumbo, Diego; Catalani, Valeria; Mari, Francesco; Patussi, Valentino; Serpelloni, Giovanni

    2017-05-01

    Clinical reliability of self-reported data for alcohol, caffeine, and nicotine consumptions is lacking, particularly in adolescents. To compare a self-report questionnaire and hair analysis to assess the reliability and effectiveness of the self-report. A cross-sectional study on 14-15-year-old Italian students (n = 874, 38% males, 62% females) was performed comparing self-reported data to hair analysis. The latter quantified hair concentrations of caffeine, nicotine, cotinine, ethyl glucuronide (EtG), and fatty acid ethyl esters (FAEEs) using mass spectrometry. Concordance between self-report and hair testing ranged from good to poor across substances and levels of use: poor for heavy alcohol intake (EtG: k = 0.36, 20 positive cases by hair analysis, false negative by self-report, 2.3% of total sample; FAEE k = 0.31, 25 positive cases, 2.9% of total sample); fair to poor for active smokers (k = 0.40, 125 positive cases, 14.3% of total sample); and moderate for caffeine (k = 0.57, 56 positive cases, 6.4% of total sample). Epidemiological studies on alcohol, caffeine, and nicotine consumption in adolescents may benefit from the inclusion of toxicological analysis on hair samples to overcome the under-reporting phenomenon of questionnaires and detect more cases of problematic substance use.

  10. A Bayesian modification to the Jelinski-Moranda software reliability growth model

    NASA Technical Reports Server (NTRS)

    Littlewood, B.; Sofer, A.

    1983-01-01

    The Jelinski-Moranda (JM) model for software reliability was examined. It is suggested that a major reason for the poor results given by this model is the poor performance of the maximum likelihood method (ML) of parameter estimation. A reparameterization and Bayesian analysis, involving a slight modelling change, are proposed. It is shown that this new Bayesian-Jelinski-Moranda model (BJM) is mathematically quite tractable, and several metrics of interest to practitioners are obtained. The BJM and JM models are compared by using several sets of real software failure data collected and in all cases the BJM model gives superior reliability predictions. A change in the assumption which underlay both models to present the debugging process more accurately is discussed.

  11. A Simple and Reliable Method of Design for Standalone Photovoltaic Systems

    NASA Astrophysics Data System (ADS)

    Srinivasarao, Mantri; Sudha, K. Rama; Bhanu, C. V. K.

    2017-06-01

    Standalone photovoltaic (SAPV) systems are seen as a promoting method of electrifying areas of developing world that lack power grid infrastructure. Proliferations of these systems require a design procedure that is simple, reliable and exhibit good performance over its life time. The proposed methodology uses simple empirical formulae and easily available parameters to design SAPV systems, that is, array size with energy storage. After arriving at the different array size (area), performance curves are obtained for optimal design of SAPV system with high amount of reliability in terms of autonomy at a specified value of loss of load probability (LOLP). Based on the array to load ratio (ALR) and levelized energy cost (LEC) through life cycle cost (LCC) analysis, it is shown that the proposed methodology gives better performance, requires simple data and is more reliable when compared with conventional design using monthly average daily load and insolation.

  12. Balancing low cost with reliable operation in the rotordynamic design of the ALS Liquid Hydrogen Fuel Turbopump

    NASA Technical Reports Server (NTRS)

    Greenhill, L. M.

    1990-01-01

    The Air Force/NASA Advanced Launch System (ALS) Liquid Hydrogen Fuel Turbopump (FTP) has primary design goals of low cost and high reliability, with performance and weight having less importance. This approach is atypical compared with other rocket engine turbopump design efforts, such as on the Space Shuttle Main Engine (SSME), which emphasized high performance and low weight. Similar to the SSME turbopumps, the ALS FTP operates supercritically, which implies that stability and bearing loads strongly influence the design. In addition, the use of low cost/high reliability features in the ALS FTP such as hydrostatic bearings, relaxed seal clearances, and unshrouded turbine blades also have a negative influence on rotordynamics. This paper discusses the analysis conducted to achieve a balance between low cost and acceptable rotordynamic behavior, to ensure that the ALS FTP will operate reliably without subsynchronous instabilities or excessive bearing loads.

  13. [Validation of a scale to assess the labour quality of life in public hospitals from Tlaxcala].

    PubMed

    Hernández-Vicente, Irma Alejandra; Lumbreras-Guzmán, Marivel; Méndez-Hernández, Pablo; Rojas-Lima, Elodia; Cervantes-Rodríguez, Margarita; Juárez-Flores, Clara Arlina

    2017-01-01

    To validate a scale for assessing the labour quality of life in public hospitals (LQL-PH) from Tlaxcala, Mexico. The instrument was validated among 669 health workers from six hospitals from the Ministry of Health of Tlaxcala, Mexico. Content validity was by inquiry to experts, construct validity by factor analysis, criterion validity by comparing with other scales, and reliability with Cronbach's Alpha. The factor analysis uncovered four dimensions: "individual welfare", "conditions and labour environment", "organization", and "well-being accomplished by the work"; reliability was 0.921. Workers who perceibed better LQL-PH were: under 50 years old, with temporary contract, with less seniority in job, with work schedule at daytime of weekends, and those with academic degree. LQL-PH showed to be an instrument phsycometrically valid and reliable. It's recommendable to prove this scale in other public and private health institutions, as well as its relationship with key health care indicators of labour performance and management.

  14. The Frontal Behavioural Inventory (Italian version) differentiates frontotemporal lobar degeneration variants from Alzheimer's disease.

    PubMed

    Alberici, A; Geroldi, C; Cotelli, M; Adorni, A; Calabria, M; Rossi, G; Borroni, B; Padovani, A; Zanetti, O; Kertesz, A

    2007-04-01

    The objective was to evaluate the construct validity of the Italian version of the Frontal Behavioural Inventory (FBI) and its usefulness in the differential diagnosis of dementias. Standard criteria were used in the clinical diagnosis of dementias in 83 patients and 33 agematched healthy volunteers. The FBI scale was translated from English into Italian language and back-translated. Cronbach's alpha, inter-rater and test-retest reliability, FBI convergent validity and discriminant analysis were calculated. FBI profile was compared between patients affected by frontotemporal lobar degeneration (FTLD) and Alzheimer's disease (AD). The FBI showed a high internal consistency and inter-rater reliability and it distinguished normal behavioural conditions from those presented in FTLD or AD. An 86.8% diagnostic accuracy was calculated by the discriminant analysis, selecting only age at disease onset and FBI, and particularly distinguishing behavioural variants within the FTLD spectrum. FTLD patients showed a characteristic behavioural profile. The FBI might be a reliable and useful diagnostic tool for dementias in clinical practice.

  15. Automatically-computed prehospital severity scores are equivalent to scores based on medic documentation.

    PubMed

    Reisner, Andrew T; Chen, Liangyou; McKenna, Thomas M; Reifman, Jaques

    2008-10-01

    Prehospital severity scores can be used in routine prehospital care, mass casualty care, and military triage. If computers could reliably calculate clinical scores, new clinical and research methodologies would be possible. One obstacle is that vital signs measured automatically can be unreliable. We hypothesized that Signal Quality Indices (SQI's), computer algorithms that differentiate between reliable and unreliable monitored physiologic data, could improve the predictive power of computer-calculated scores. In a retrospective analysis of trauma casualties transported by air ambulance, we computed the Triage Revised Trauma Score (RTS) from archived travel monitor data. We compared the areas-under-the-curve (AUC's) of receiver operating characteristic curves for prediction of mortality and red blood cell transfusion for 187 subjects with comparable quantities of good-quality and poor-quality data. Vital signs deemed reliable by SQI's led to significantly more discriminatory severity scores than vital signs deemed unreliable. We also compared automatically-computed RTS (using the SQI's) versus RTS computed from vital signs documented by medics. For the subjects in whom the SQI algorithms identified 15 consecutive seconds of reliable vital signs data (n = 350), the automatically-computed scores' AUC's were the same as the medic-based scores' AUC's. Using the Prehospital Index in place of RTS led to very similar results, corroborating our findings. SQI algorithms improve automatically-computed severity scores, and automatically-computed scores using SQI's are equivalent to medic-based scores.

  16. Evolution of Safety Analysis to Support New Exploration Missions

    NASA Technical Reports Server (NTRS)

    Thrasher, Chard W.

    2008-01-01

    NASA is currently developing the Ares I launch vehicle as a key component of the Constellation program which will provide safe and reliable transportation to the International Space Station, back to the moon, and later to Mars. The risks and costs of the Ares I must be significantly lowered, as compared to other manned launch vehicles, to enable the continuation of space exploration. It is essential that safety be significantly improved, and cost-effectively incorporated into the design process. This paper justifies early and effective safety analysis of complex space systems. Interactions and dependences between design, logistics, modeling, reliability, and safety engineers will be discussed to illustrate methods to lower cost, reduce design cycles and lessen the likelihood of catastrophic events.

  17. Construct validity, test-retest reliability and internal consistency of the Thai version of the disabilities of the arm, shoulder and hand questionnaire (DASH-TH) in patients with carpal tunnel syndrome.

    PubMed

    Buntragulpoontawee, Montana; Phutrit, Suphatha; Tongprasert, Siam; Wongpakaran, Tinakon; Khunachiva, Jeeranan

    2018-03-27

    This study evaluated additional psychometric properties of the Thai version of the disabilities of the arm, shoulder and hand questionnaire (DASH-TH) which included, test-retest reliability, construct validity, internal consistency of in patients with carpal tunnel syndrome. As for determining construct validity, the Thai EuroQOL questionnaire (EQ-5D-5L) was also administered in order to examine convergent and divergent validity. Fifty patients completed both questionnaires. The DASH-TH showed excellent test-retest reliability (intraclass correlation coefficient = 0.811) and internal consistency (Cronbach's alpha = 0.911). The exploratory factor analysis yielded a six-factor solution while the confirmatory factor analysis denoted that the hypothesized model adequately fit the data with a comparative fit index of 0.967 and a Tucker-Lewis index of 0.964. The related subscales between the DASH-TH and the Thai EQ-5D-5L were significantly correlated, indicating the DASH-TH's convergent and discriminant validity. The DASH-TH demonstrated good reliability, internal consistency construct validity, and multidimensionality, in assessing the upper extremity function in carpal tunnel syndrome patients.

  18. [Psychometric validation in Spanish of the Brazilian short version of the Primary Care Assessment Tools-users questionnaire for the evaluation of the orientation of health systems towards primary care].

    PubMed

    Vázquez Peña, Fernando; Harzheim, Erno; Terrasa, Sergio; Berra, Silvina

    2017-02-01

    To validate the Brazilian short version of the PCAT for adult patients in Spanish. Analysis of secondary data from studies made to validate the extended version of the PCAT questionnaire. City of Córdoba, Argentina. Primary health care. The sample consisted of 46% of parents, whose children were enrolled in secondary education in three institutes in the city of Cordoba, and the remaining 54% were adult users of the National University of Cordoba Health Insurance. Pearson's correlation coefficient comparing the extended and short versions. Goodness-of-fit indices in confirmatory factor analysis, composite reliability, average variance extracted, and Cronbach's alpha values, in order to assess the construct validity and the reliability of the short version. The values of Pearson's correlation coefficient between this short version and the long version were high .818 (P<.001), implying a very good criterion validity. The indicators of good global adjustment to the confirmatory factor analysis were good. The value of composite reliability was good (.802), but under the variance media extracted: .3306, since 3 variables had weak factorials loads. The Cronbach's alpha was acceptable (.85). The short version of the PCAT-users developed in Brazil showed an acceptable psychometric performance in Spanish as a quick assessment tool, in a comparative study with the extended version. Copyright © 2016 Elsevier España, S.L.U. All rights reserved.

  19. Breast volumetric analysis for aesthetic planning in breast reconstruction: a literature review of techniques

    PubMed Central

    Rozen, Warren Matthew; Spychal, Robert T.; Hunter-Smith, David J.

    2016-01-01

    Background Accurate volumetric analysis is an essential component of preoperative planning in both reconstructive and aesthetic breast procedures towards achieving symmetrization and patient-satisfactory outcome. Numerous comparative studies and reviews of individual techniques have been reported. However, a unifying review of all techniques comparing their accuracy, reliability, and practicality has been lacking. Methods A review of the published English literature dating from 1950 to 2015 using databases, such as PubMed, Medline, Web of Science, and EMBASE, was undertaken. Results Since Bouman’s first description of water displacement method, a range of volumetric assessment techniques have been described: thermoplastic casting, direct anthropomorphic measurement, two-dimensional (2D) imaging, and computed tomography (CT)/magnetic resonance imaging (MRI) scans. However, most have been unreliable, difficult to execute and demonstrate limited practicability. Introduction of 3D surface imaging has revolutionized the field due to its ease of use, fast speed, accuracy, and reliability. However, its widespread use has been limited by its high cost and lack of high level of evidence. Recent developments have unveiled the first web-based 3D surface imaging program, 4D imaging, and 3D printing. Conclusions Despite its importance, an accurate, reliable, and simple breast volumetric analysis tool has been elusive until the introduction of 3D surface imaging technology. However, its high cost has limited its wide usage. Novel adjunct technologies, such as web-based 3D surface imaging program, 4D imaging, and 3D printing, appear promising. PMID:27047788

  20. The Self-Stigma of Depression Scale: Translation and Validation of the Arabic Version

    PubMed Central

    Darraj, Hussain Ahmed; Mahfouz, Mohamed Salih; Al Sanosi, Rashad Mohamed; Badedi, Mohammed; Sabai, Abdullah

    2017-01-01

    Background: Self-stigma may feature strongly and be detrimental for people with depression, but the understanding of its nature and prevalence is limited by the lack of psychometrically validated measures. This study is aimed to validate the Arabic version self-stigma of depression scale (SSDS) among adolescents. Materials and Methods: A cross-sectional study involved 100 adolescents randomly selected. The analyses include face validation, factor analysis, and reliability testing. A test–retest was conducted within a 2-week interval. Results: The mean score for self-stigma of depression among study participants was 68.9 (Standard deviation = 8.76) median equal to 71 and range was 47. Descriptive analysis showed that the percentage of those who scored below the mean score (41.7%) is shown less than those who scored above the mean score (58.3%). Preliminary construct validation analysis confirmed that factor analysis was appropriate for the Arabic-translated version of the SSDS. Furthermore, the factor analysis showed similar factor loadings to the original English version. The total internal consistency of the translated version, which was measured by Cronbach's alphas ranged from 0.70 to 0.77 for the four subscales and 0.84 for the total scale. Test–retest reliability was assessed in 65 respondents after 2 weeks. Cronbach's alphas ranged from 0.70 to 0.77 for the four subscales and 0.84 for the total scale. Conclusions: Face validity, construct validity, and reliability analysis were found satisfactory for the Arabic-translated version of the SSDS. The Arabic-translated version of the SSDS was found valid and reliable to be used in future studies, with comparable properties to the original version and to previous studies. PMID:28149090

  1. 75 FR 5633 - Notice of Extension of Comment Period for NUREG-1921, EPRI/NRC-RES Fire Human Reliability...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-02-03

    ..., EPRI/NRC- RES Fire Human Reliability Analysis Guidelines, Draft Report for Comment AGENCY: Nuclear... Human Reliability Analysis Guidelines, Draft Report for Comment'' (December 11, 2009; 74 FR 65810). This... Human Reliability Analysis Guidelines'' is available electronically under ADAMS Accession Number...

  2. Determining mutation density using Restriction Enzyme Sequence Comparative Analysis (RESCAN)

    USDA-ARS?s Scientific Manuscript database

    The average mutation density of a mutant population is a major consideration when developing resources for the efficient, cost-effective implementation of reverse genetics methods such as Targeting of Induced Local Lesions in Genomes (TILLING). Reliable estimates of mutation density can be achieved ...

  3. Psychometric Characteristics of the Modified World Affairs Questionnaire.

    ERIC Educational Resources Information Center

    Mayton, Daniel M., II

    1988-01-01

    Subjected Modified World Affairs Questionnaire (MWAQ) to comparable common factor analysis which identified five factors: civil defense, escalation, nuclear war outcome, probability/worry, and patriotic. Alpha coefficients and test-retest reliability were determined to be adequate for the first four subscales. Acceptable discriminant validity and…

  4. Methods to assess pecan scab

    USDA-ARS?s Scientific Manuscript database

    Pecan scab (Fusicladium effusum [G. Winter]) is the most important disease of pecan in the U.S. Measuring the severity of scab accurately and reliably and providing data amenable to analysis using parametric statistics is important where treatments are being compared to minimize the risk of Type II ...

  5. Reliability of Soft Tissue Model Based Implant Surgical Guides; A Methodological Mistake.

    PubMed

    Sabour, Siamak; Dastjerdi, Elahe Vahid

    2012-08-20

    Abstract We were interested to read the paper by Maney P and colleagues published in the July 2012 issue of J Oral Implantol. The authors aimed to assess the reliability of soft tissue model based implant surgical guides reported that the accuracy was evaluated using software. 1 I found the manuscript title of Maney P, et al. incorrect and misleading. Moreover, they reported twenty-two sites (46.81%) were considered accurate (13 of 24 maxillary and 9 of 23 mandibular sites). As the authors point out in their conclusion, Soft tissue models do not always provide sufficient accuracy for implant surgical guide fabrication.Reliability (precision) and validity (accuracy) are two different methodological issues in researches. Sensitivity, specificity, PPV, NPV, likelihood ratio positive (true positive/false negative) and likelihood ratio negative (false positive/ true negative) as well as odds ratio (true results\\false results - preferably more than 50) are among the tests to evaluate the validity (accuracy) of a single test compared to a gold standard.2-4 It is not clear that the reported twenty-two sites (46.81%) which were considered accurate related to which of the above mentioned estimates for validity analysis. Reliability (repeatability or reproducibility) is being assessed by different statistical tests such as Pearson r, least square and paired t.test which all of them are among common mistakes in reliability analysis 5. Briefly, for quantitative variable Intra Class Correlation Coefficient (ICC) and for qualitative variables weighted kappa should be used with caution because kappa has its own limitation too. Regarding reliability or agreement, it is good to know that for computing kappa value, just concordant cells are being considered, whereas discordant cells should also be taking into account in order to reach a correct estimation of agreement (Weighted kappa).2-4 As a take home message, for reliability and validity analysis, appropriate tests should be applied.

  6. Reliability of drivers in urban intersections.

    PubMed

    Gstalter, Herbert; Fastenmeier, Wolfgang

    2010-01-01

    The concept of human reliability has been widely used in industrial settings by human factors experts to optimise the person-task fit. Reliability is estimated by the probability that a task will successfully be completed by personnel in a given stage of system operation. Human Reliability Analysis (HRA) is a technique used to calculate human error probabilities as the ratio of errors committed to the number of opportunities for that error. To transfer this notion to the measurement of car driver reliability the following components are necessary: a taxonomy of driving tasks, a definition of correct behaviour in each of these tasks, a list of errors as deviations from the correct actions and an adequate observation method to register errors and opportunities for these errors. Use of the SAFE-task analysis procedure recently made it possible to derive driver errors directly from the normative analysis of behavioural requirements. Driver reliability estimates could be used to compare groups of tasks (e.g. different types of intersections with their respective regulations) as well as groups of drivers' or individual drivers' aptitudes. This approach was tested in a field study with 62 drivers of different age groups. The subjects drove an instrumented car and had to complete an urban test route, the main features of which were 18 intersections representing six different driving tasks. The subjects were accompanied by two trained observers who recorded driver errors using standardized observation sheets. Results indicate that error indices often vary between both the age group of drivers and the type of driving task. The highest error indices occurred in the non-signalised intersection tasks and the roundabout, which exactly equals the corresponding ratings of task complexity from the SAFE analysis. A comparison of age groups clearly shows the disadvantage of older drivers, whose error indices in nearly all tasks are significantly higher than those of the other groups. The vast majority of these errors could be explained by high task load in the intersections, as they represent difficult tasks. The discussion shows how reliability estimates can be used in a constructive way to propose changes in car design, intersection layout and regulation as well as driver training.

  7. Comparative measurement of collagen bundle orientation by Fourier analysis and semiquantitative evaluation: reliability and agreement in Masson's trichrome, Picrosirius red and confocal microscopy techniques.

    PubMed

    Marcos-Garcés, V; Harvat, M; Molina Aguilar, P; Ferrández Izquierdo, A; Ruiz-Saurí, A

    2017-08-01

    Measurement of collagen bundle orientation in histopathological samples is a widely used and useful technique in many research and clinical scenarios. Fourier analysis is the preferred method for performing this measurement, but the most appropriate staining and microscopy technique remains unclear. Some authors advocate the use of Haematoxylin-Eosin (H&E) and confocal microscopy, but there are no studies comparing this technique with other classical collagen stainings. In our study, 46 human skin samples were collected, processed for histological analysis and stained with Masson's trichrome, Picrosirius red and H&E. Five microphotographs of the reticular dermis were taken with a 200× magnification with light microscopy, polarized microscopy and confocal microscopy, respectively. Two independent observers measured collagen bundle orientation with semiautomated Fourier analysis with the Image-Pro Plus 7.0 software and three independent observers performed a semiquantitative evaluation of the same parameter. The average orientation for each case was calculated with the values of the five pictures. We analyzed the interrater reliability, the consistency between Fourier analysis and average semiquantitative evaluation and the consistency between measurements in Masson's trichrome, Picrosirius red and H&E-confocal. Statistical analysis for reliability and agreement was performed with the SPSS 22.0 software and consisted of intraclass correlation coefficient (ICC), Bland-Altman plots and limits of agreement and coefficient of variation. Interrater reliability was almost perfect (ICC > 0.8) with all three histological and microscopy techniques and always superior in Fourier analysis than in average semiquantitative evaluation. Measurements were consistent between Fourier analysis by one observer and average semiquantitative evaluation by three observers, with an almost perfect agreement with Masson's trichrome and Picrosirius red techniques (ICC > 0.8) and a strong agreement with H&E-confocal (0.7 < ICC < 0.8). Comparison of measurements between the three techniques for the same observer showed an almost perfect agreement (ICC > 0.8), better with Fourier analysis than with semiquantitative evaluation (single and average). These results in nonpathological skin samples were also confirmed in a preliminary analysis in eight scleroderma skin samples. Our results show that Masson's trichrome and Picrosirius red are consistent with H&E-confocal for measuring collagen bundle orientation in histological samples and could thus be used indistinctly for this purpose. Fourier analysis is superior to average semiquantitative evaluation and should keep being used as the preferred method. © 2017 The Authors Journal of Microscopy © 2017 Royal Microscopical Society.

  8. Wind energy Computerized Maintenance Management System (CMMS) : data collection recommendations for reliability analysis.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Peters, Valerie A.; Ogilvie, Alistair B.

    2012-01-01

    This report addresses the general data requirements for reliability analysis of fielded wind turbines and other wind plant equipment. The report provides a rationale for why this data should be collected, a list of the data needed to support reliability and availability analysis, and specific data recommendations for a Computerized Maintenance Management System (CMMS) to support automated analysis. This data collection recommendations report was written by Sandia National Laboratories to address the general data requirements for reliability analysis of operating wind turbines. This report is intended to help develop a basic understanding of the data needed for reliability analysis frommore » a Computerized Maintenance Management System (CMMS) and other data systems. The report provides a rationale for why this data should be collected, a list of the data needed to support reliability and availability analysis, and specific recommendations for a CMMS to support automated analysis. Though written for reliability analysis of wind turbines, much of the information is applicable to a wider variety of equipment and analysis and reporting needs. The 'Motivation' section of this report provides a rationale for collecting and analyzing field data for reliability analysis. The benefits of this type of effort can include increased energy delivered, decreased operating costs, enhanced preventive maintenance schedules, solutions to issues with the largest payback, and identification of early failure indicators.« less

  9. [Mirtazapine versus other antidepressive agents for depression].

    PubMed

    Knud Larsen, Jens

    2012-11-12

    A Cochrane analysis compared efficacy and side effects of mirtazapine with other antidepressants. After six weeks of treatment no reliable difference of efficacy between mirtazapine, selective serotonin reuptake inhibitors (SSRI), noradrenaline reuptake inhibitors or tricyclic antidepressants was found. The side effects like increased sleep and weight gain were compared by treatment with mirtazapine and treatment with SSRI antidepressants. The very fact of the sleep effect and the fast onset of action have probably increased the effect size compared with SSRI antidepressants. The results of the Cochrane analysis cannot for certain be generalized to inpatients, as other studies have found tricyclic antidepressants to be especially effective.

  10. True communication skills assessment in interdepartmental OSCE stations: Standard setting using the MAAS-Global and EduG.

    PubMed

    Setyonugroho, Winny; Kropmans, Thomas; Murphy, Ruth; Hayes, Peter; van Dalen, Jan; Kennedy, Kieran M

    2018-01-01

    Comparing outcome of clinical skills assessment is challenging. This study proposes reliable and valid comparison of communication skills (1) assessment as practiced in Objective Structured Clinical Examinations (2). The aim of the present study is to compare CS assessment, as standardized according to the MAAS Global, between stations in a single undergraduate medical year. An OSCE delivered in an Irish undergraduate curriculum was studied. We chose the MAAS-Global as an internationally recognized and validated instrument to calibrate the OSCE station items. The MAAS-Global proportion is the percentage of station checklist items that can be considered as 'true' CS. The reliability of the OSCE was calculated with G-Theory analysis and nested ANOVA was used to compare mean scores of all years. MAAS-Global scores in psychiatry stations were significantly higher than those in other disciplines (p<0.03) and above the initial pass mark of 50%. The higher students' scores in psychiatry stations were related to higher MAAS-Global proportions when compared to the general practice stations. Comparison of outcome measurements, using the MAAS Global as a standardization instrument, between interdisciplinary station checklists was valid and reliable. The MAAS-Global was used as a single validated instrument and is suggested as gold standard. Copyright © 2017. Published by Elsevier B.V.

  11. A validation study of the Keyboard Personal Computer Style instrument (K-PeCS) for use with children.

    PubMed

    Green, Dido; Meroz, Anat; Margalit, Adi Edit; Ratzon, Navah Z

    2012-11-01

    This study examines a potential instrument for measurement of typing postures of children. This paper describes inter-rater, test-retest reliability and concurrent validity of the Keyboard Personal Computer Style instrument (K-PeCS), an observational measurement of postures and movements during keyboarding, for use with children. Two trained raters independently rated videos of 24 children (aged 7-10 years). Six children returned one week later for identifying test-retest reliability. Concurrent validity was assessed by comparing ratings obtained using the K-PECS to scores from a 3D motion analysis system. Inter-rater reliability was moderate to high for 12 out of 16 items (Kappa: 0.46 to 1.00; correlation coefficients: 0.77-0.95) and test-retest reliability varied across items (Kappa: 0.25 to 0.67; correlation coefficients: r = 0.20 to r = 0.95). Concurrent validity compared favourably across arm pathlength, wrist extension and ulnar deviation. In light of the limitations of other tools the K-PeCS offers a fairly affordable, reliable and valid instrument to address the gap for measurement of typing styles of children, despite the shortcomings of some items. However further research is required to refine the instrument for use in evaluating typing among children. Copyright © 2012 Elsevier Ltd and The Ergonomics Society. All rights reserved.

  12. Dental age estimation: Comparison of reliability between Malay formula of Demirjian method and Malay formula of Cameriere method

    NASA Astrophysics Data System (ADS)

    Alghali, R.; Kamaruddin, A. F.; Mokhtar, N.

    2016-12-01

    Introduction: The application of forensic odontology using teeth and bones becomes the most commonly used methods to determine age of unknown individuals. Objective: The aim of this study was to determine the reliability of Malay formula of Demirjian and Malay formula of Cameriere methods in determining the dental age that is closely matched with the chronological age of Malay children in Kepala Batas region. Methodology: This is a retrospective cross-sectional study. 126 good quality dental panoramic radiographs (DPT) of healthy Malay children aged 8-16 years (49 boys and 77 girls) were selected and measured. All radiographs were taken at Dental Specialist Clinic, Advanced Medical and Dental Institute, Universiti Sains Malaysia. The measurements were carried out using new Malay formula of both Demirjian and Cameriere methods by calibrated examiner. Results: The intraclass correlation coefficient (ICC) analysis between the chronological age with Demirjian and Cameriere has been calculated. The Demirjian method has shown a better percentage (91.4%) of ICC compared to Cameriere (89.2%) which also indicates a high association, with good reliability. However, by comparing between Demirjian and Cameriere, it can be concluded that Demirjian has a better reliability. Conclusion: Thus, the results suggested that, modified Demirjian method is more reliable than modified Cameriere method among the population in Kepala Batas region.

  13. Rasch analysis of the Edmonton Symptom Assessment System and research implications

    PubMed Central

    Cheifetz, O.; Packham, T.L.; MacDermid, J.C.

    2014-01-01

    Background Reliable and valid assessment of the disease burden across all forms of cancer is critical to the evaluation of treatment effectiveness and patient progress. The Edmonton Symptom Assessment System (esas) is used for routine evaluation of people attending for cancer care. In the present study, we used Rasch analysis to explore the measurement properties of the esas and to determine the effect of using Rasch-proposed interval-level esas scoring compared with traditional scoring when evaluating the effects of an exercise program for cancer survivors. Methods Polytomous Rasch analysis (Andrich’s rating-scale model) was applied to data from 26,645 esas questionnaires completed at the Juravinski Cancer Centre. The fit of the esas to the polytomous Rasch model was investigated, including evaluations of differential item functioning for sex, age, and disease group. The research implication was investigated by comparing the results of an observational research study previously analysed using a traditional approach with the results obtained by Rasch-proposed interval-level esas scoring. Results The Rasch reliability index was 0.73, falling short of the desired 0.80–0.90 level. However, the esas was found to fit the Rasch model, including the criteria for uni-dimensional data. The analysis suggests that the current esas scoring system of 0–10 could be collapsed to a 6-point scale. Use of the Rasch-proposed interval-level scoring yielded results that were different from those calculated using summarized ordinal-level esas scores. Differential item functioning was not found for sex, age, or diagnosis groups. Conclusions The esas is a moderately reliable uni-dimensional measure of cancer disease burden and can provide interval-level scaling with Rasch-based scoring. Further, our study indicates that, compared with the traditional scoring metric, Rasch-based scoring could result in substantive changes to conclusions. PMID:24764703

  14. Trajectory analysis of Polar Patrol Balloon (PPB) flights in the stratosphere over Antarctica in summer and spring: A preliminary result

    NASA Technical Reports Server (NTRS)

    Kanzawa, Hiroshi; Fujii, Ryoichi; Yamazaki, Koji; Yamanaka, Manabu D.

    1994-01-01

    Actual trajectories of two PPB's which flew in the Antarctic stratosphere in austral summer and spring are compared with those calculated based on objective analysis data of Japan Meteorological Agency (JMA). The differences between the actual and calculated trajectories are discussed to check reliability of the JMA objective analysis data for the stratosphere, and to detect subsynoptic scale variability due to gravity waves and others.

  15. Test-Retest Reliability of Diffusion Tensor Imaging in Huntington's Disease.

    PubMed

    Cole, James H; Farmer, Ruth E; Rees, Elin M; Johnson, Hans J; Frost, Chris; Scahill, Rachael I; Hobbs, Nicola Z

    2014-03-21

    Diffusion tensor imaging (DTI) has shown microstructural abnormalities in patients with Huntington's Disease (HD) and work is underway to characterise how these abnormalities change with disease progression. Using methods that will be applied in longitudinal research, we sought to establish the reliability of DTI in early HD patients and controls. Test-retest reliability, quantified using the intraclass correlation coefficient (ICC), was assessed using region-of-interest (ROI)-based white matter atlas and voxelwise approaches on repeat scan data from 22 participants (10 early HD, 12 controls). T1 data was used to generate further ROIs for analysis in a reduced sample of 18 participants. The results suggest that fractional anisotropy (FA) and other diffusivity metrics are generally highly reliable, with ICCs indicating considerably lower within-subject compared to between-subject variability in both HD patients and controls. Where ICC was low, particularly for the diffusivity measures in the caudate and putamen, this was partly influenced by outliers. The analysis suggests that the specific DTI methods used here are appropriate for cross-sectional research in HD, and give confidence that they can also be applied longitudinally, although this requires further investigation. An important caveat for DTI studies is that test-retest reliability may not be evenly distributed throughout the brain whereby highly anisotropic white matter regions tended to show lower relative within-subject variability than other white or grey matter regions.

  16. Reliability and validity of the Turkish version of the situational self-efficacy scale for fruit and vegetable consumption in adolescents.

    PubMed

    Kadioglu, Hasibe; Erol, Saime; Ergun, Ayse

    2015-01-01

    The purpose of this research was to examine the psychometric properties of the Turkish version of the situational self-efficacy scale for vegetable and fruit consumption in adolescents. This was a methodological study. The study was conducted in four public secondary schools in Istanbul, Turkey. Subjects were 1586 adolescents. Content and construct validity were assessed to test the validity of the scale. The reliability was assessed in terms of internal consistency and test-retest reliability. For confirmatory factor analysis, χ(2) statistics plus other fit indices were used, including the goodness-of-fit index, the adjusted goodness-of-fit index, the nonnormed fit index, the comparative fit index, the standardized root mean residual, and the root mean square error of approximation. Pearson's correlation was used for test-retest reliability and item total correlation. The internal consistency was assessed by using Cronbach α. Confirmatory factor analysis strongly supported the three-component structure representing positive social situations (α = .81), negative effect situations (α = .93), and difficult situations (α = .78). Psychometric analyses of the Turkish version of the situational self-efficacy scale indicate high reliability and good content and construct validity. Researchers and health professionals will find it useful to employ the Turkish situational self-efficacy scale in evaluating situational self-efficacy for fruit and vegetable consumption in Turkish adolescents.

  17. [A comparative analysis of the brain activity during the traditional and intensive forms of learning foreign languages].

    PubMed

    Bykova, L G; Bazylev, V N

    1994-01-01

    By means of dichotic test the comparative research of the brain activity in dynamics in 84 adult students was conducted during their traditional (36 persons) and intensive (48 persons) learning of foreign languages. By different methods of learning the reliable distinction of the hemisphere's asymmetry was not detected. By both methods in the reliable majority of students the activation of the hemisphere opposite to the one dominating initially was observed. The correlation between the maximum quantitative shift of the right ear coefficient and the level of success in colloquial practice by the same initial level of language start and initial comparable size of memory was revealed. The authors discuss the possibility of the individual map composition for every student using the results of dichotic tests in dynamics for the help in the profession of a teacher.

  18. Improving the reliability of female fertility breeding values using type and milk yield traits that predict energy status in Australian Holstein cattle.

    PubMed

    González-Recio, O; Haile-Mariam, M; Pryce, J E

    2016-01-01

    The objectives of this study were (1) to propose changing the selection criteria trait for evaluating fertility in Australia from calving interval to conception rate at d 42 after the beginning of the mating season and (2) to use type traits as early fertility predictors, to increase the reliability of estimated breeding values for fertility. The breeding goal in Australia is conception within 6 wk of the start of the mating season. Currently, the Australian model to predict fertility breeding values (expressed as a linear transformation of calving interval) is a multitrait model that includes calving interval (CVI), lactation length (LL), calving to first service (CFS), first nonreturn rate (FNRR), and conception rate. However, CVI has a lower genetic correlation with the breeding goal (conception within 6 wk of the start of the mating season) than conception rate. Milk yield, type, and fertility data from 164,318 cow sired by 4,766 bulls were used. Principal component analysis and genetic correlation estimates between type and fertility traits were used to select type traits that could subsequently be used in a multitrait analysis. Angularity, foot angle, and pin set were chosen as type traits to include in an index with the traits that are included in the multitrait fertility model: CVI, LL, CFS, FNRR, and conception rate at d 42 (CR42). An index with these 8 traits is expected to achieve an average bull first proof reliability of 0.60 on the breeding objective (conception within 6 wk of the start of the mating season) compared with reliabilities of 0.39 and 0.45 for CR42 only or the current 5-trait Australian model. Subsequently, we used the first eigenvector of a principal component analysis with udder texture, bone quality, angularity, and body condition score to calculate an energy status indicator trait. The inclusion of the energy status indicator trait composite in a multitrait index with CVI, LL, CFS, FNRR, and CR42 achieved a 12-point increase in fertility breeding value reliability (i.e., increased by 30%; up to 0.72 points of reliability), whereas a lower increase in reliability (4 points, i.e., increased by 10%) was obtained by including angularity, foot angle, and pin set in the index. In situations when a limited number of daughters have been phenotyped for CR42, including type data for sires increased reliabilities compared with when type data were omitted. However, sires with more than 80 daughters with CR42 records achieved reliability estimates close to 80% on average, and there did not appear to be a benefit from having daughters with type records. The cost of phenotyping to obtain such reliabilities (assuming a cost of AU$14 per cow with type data and AU$5 per cow with pregnancy diagnosed) is lower if more pregnancy data are collected in preference to type data. That is, efforts to increase the reliability of fertility EBV are most cost effective when directed at obtaining a larger number of pregnancy tests. Copyright © 2016 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  19. Assessment of the transportation route of oversize and excessive loads in relation to the load-bearing capacity of existing bridges

    NASA Astrophysics Data System (ADS)

    Doležel, Jiří; Novák, Drahomír; Petrů, Jan

    2017-09-01

    Transportation routes of oversize and excessive loads are currently planned in relation to ensure the transit of a vehicle through critical points on the road. Critical points are level-intersection of roads, bridges etc. This article presents a comprehensive procedure to determine a reliability and a load-bearing capacity level of the existing bridges on highways and roads using the advanced methods of reliability analysis based on simulation techniques of Monte Carlo type in combination with nonlinear finite element method analysis. The safety index is considered as a main criterion of the reliability level of the existing construction structures and the index is described in current structural design standards, e.g. ISO and Eurocode. An example of a single-span slab bridge made of precast prestressed concrete girders of the 60 year current time and its load bearing capacity is set for the ultimate limit state and serviceability limit state. The structure’s design load capacity was estimated by the full probability nonlinear MKP analysis using a simulation technique Latin Hypercube Sampling (LHS). Load-bearing capacity values based on a fully probabilistic analysis are compared with the load-bearing capacity levels which were estimated by deterministic methods of a critical section of the most loaded girders.

  20. Reliability of corneal dynamic scheimpflug analyser measurements in virgin and post-PRK eyes.

    PubMed

    Chen, Xiangjun; Stojanovic, Aleksandar; Hua, Yanjun; Eidet, Jon Roger; Hu, Di; Wang, Jingting; Utheim, Tor Paaske

    2014-01-01

    To determine the measurement reliability of CorVis ST, a dynamic Scheimpflug analyser, in virgin and post-photorefractive keratectomy (PRK) eyes and compare the results between these two groups. Forty virgin eyes and 42 post-PRK eyes underwent CorVis ST measurements performed by two technicians. Repeatability was evaluated by comparing three consecutive measurements by technician A. Reproducibility was determined by comparing the first measurement by technician A with one performed by technician B. Intraobserver and interobserver intraclass correlation coefficients (ICCs) were calculated. Univariate analysis of covariance (ANCOVA) was used to compare measured parameters between virgin and post-PRK eyes. The intraocular pressure (IOP), central corneal thickness (CCT) and 1st applanation time demonstrated good intraobserver repeatability and interobserver reproducibility (ICC ≧ 0.90) in virgin and post-PRK eyes. The deformation amplitude showed a good or close to good repeatability and reproducibility in both groups (ICC ≧ 0.88). The CCT correlated positively with 1st applanation time (r = 0.437 and 0.483, respectively, p<0.05) and negatively with deformation amplitude (r = -0.384 and -0.375, respectively, p<0.05) in both groups. Compared to post-PRK eyes, virgin eyes showed longer 1st applanation time (7.29 ± 0.21 vs. 6.96 ± 0.17 ms, p<0.05) and lower deformation amplitude (1.06 ± 0.07 vs. 1.17 ± 0.08 mm, p < 0.05). CorVis ST demonstrated reliable measurements for CCT, IOP, and 1st applanation time, as well as relatively reliable measurement for deformation amplitude in both virgin and post-PRK eyes. There were differences in 1st applanation time and deformation amplitude between virgin and post-PRK eyes, which may reflect corneal biomechanical changes occurring after the surgery in the latter.

  1. An Analysis Technique/Automated Tool for Comparing and Tracking Analysis Modes of Different Finite Element Models

    NASA Technical Reports Server (NTRS)

    Towner, Robert L.; Band, Jonathan L.

    2012-01-01

    An analysis technique was developed to compare and track mode shapes for different Finite Element Models. The technique may be applied to a variety of structural dynamics analyses, including model reduction validation (comparing unreduced and reduced models), mode tracking for various parametric analyses (e.g., launch vehicle model dispersion analysis to identify sensitivities to modal gain for Guidance, Navigation, and Control), comparing models of different mesh fidelity (e.g., a coarse model for a preliminary analysis compared to a higher-fidelity model for a detailed analysis) and mode tracking for a structure with properties that change over time (e.g., a launch vehicle from liftoff through end-of-burn, with propellant being expended during the flight). Mode shapes for different models are compared and tracked using several numerical indicators, including traditional Cross-Orthogonality and Modal Assurance Criteria approaches, as well as numerical indicators obtained by comparing modal strain energy and kinetic energy distributions. This analysis technique has been used to reliably identify correlated mode shapes for complex Finite Element Models that would otherwise be difficult to compare using traditional techniques. This improved approach also utilizes an adaptive mode tracking algorithm that allows for automated tracking when working with complex models and/or comparing a large group of models.

  2. Reliability of lower limb alignment measures using an established landmark-based method with a customized computer software program

    PubMed Central

    Sled, Elizabeth A.; Sheehy, Lisa M.; Felson, David T.; Costigan, Patrick A.; Lam, Miu; Cooke, T. Derek V.

    2010-01-01

    The objective of the study was to evaluate the reliability of frontal plane lower limb alignment measures using a landmark-based method by (1) comparing inter- and intra-reader reliability between measurements of alignment obtained manually with those using a computer program, and (2) determining inter- and intra-reader reliability of computer-assisted alignment measures from full-limb radiographs. An established method for measuring alignment was used, involving selection of 10 femoral and tibial bone landmarks. 1) To compare manual and computer methods, we used digital images and matching paper copies of five alignment patterns simulating healthy and malaligned limbs drawn using AutoCAD. Seven readers were trained in each system. Paper copies were measured manually and repeat measurements were performed daily for 3 days, followed by a similar routine with the digital images using the computer. 2) To examine the reliability of computer-assisted measures from full-limb radiographs, 100 images (200 limbs) were selected as a random sample from 1,500 full-limb digital radiographs which were part of the Multicenter Osteoarthritis (MOST) Study. Three trained readers used the software program to measure alignment twice from the batch of 100 images, with two or more weeks between batch handling. Manual and computer measures of alignment showed excellent agreement (intraclass correlations [ICCs] 0.977 – 0.999 for computer analysis; 0.820 – 0.995 for manual measures). The computer program applied to full-limb radiographs produced alignment measurements with high inter- and intra-reader reliability (ICCs 0.839 – 0.998). In conclusion, alignment measures using a bone landmark-based approach and a computer program were highly reliable between multiple readers. PMID:19882339

  3. Reliability and Validity of the Greek Migraine Disability Assessment (MIDAS) Questionnaire.

    PubMed

    Oikonomidi, Theodora; Vikelis, Michail; Artemiadis, Artemios; Chrousos, George P; Darviri, Christina

    2018-03-01

    The Migraine Disability Assessment (MIDAS) Questionnaire is a reliable and valid instrument for migraine-related disability. Such a tool is needed to quantify migraine-related disability in the Greek population. This validation study aims to assess the test-retest reliability, internal consistency, item discriminant and convergent validity of the Greek translation of the MIDAS. Adults diagnosed with migraine completed the MIDAS Questionnaire on two occasions 3 weeks apart to assess reliability, and completed the RAND-36 to assess validity. Participants (n = 152) had a median MIDAS score of 24 and mostly severe disability (58% were grade IV). The test-retest reliability analysis (N = 59) revealed excellent reliability for the total score. Internal consistency was α = 0.71 for initial and α = 0.82 for retest completion. For item discriminant validity, the correlations between each question and the total score were significant, with high correlations for questions 2-5 (range 0.67 ≤ r ≤ 0.79; p < 0.01). For convergent validity, there was significant negative correlation between the total score and all RAND-36 subscales except for 'emotional wellbeing'. The negative correlation indicates that patients with a lower degree of disability according to their MIDAS score tended to have better wellbeing. Psychometric properties are comparable with those of other published validation studies of the MIDAS and the original. Findings on question 1 show that missing work/school days may be closely related with increased affect issues. The Greek version of the MIDAS Questionnaire has good reliability and validity. This study allowed for cross-cultural comparability of research findings.

  4. Efficacy of a Newly Designed Cephalometric Analysis Software for McNamara Analysis in Comparison with Dolphin Software.

    PubMed

    Nouri, Mahtab; Hamidiaval, Shadi; Akbarzadeh Baghban, Alireza; Basafa, Mohammad; Fahim, Mohammad

    2015-01-01

    Cephalometric norms of McNamara analysis have been studied in various populations due to their optimal efficiency. Dolphin cephalometric software greatly enhances the conduction of this analysis for orthodontic measurements. However, Dolphin is very expensive and cannot be afforded by many clinicians in developing countries. A suitable alternative software program in Farsi/English will greatly help Farsi speaking clinicians. The present study aimed to develop an affordable Iranian cephalometric analysis software program and compare it with Dolphin, the standard software available on the market for cephalometric analysis. In this diagnostic, descriptive study, 150 lateral cephalograms of normal occlusion individuals were selected in Mashhad and Qazvin, two major cities of Iran mainly populated with Fars ethnicity, the main Iranian ethnic group. After tracing the cephalograms, the McNamara analysis standards were measured both with Dolphin and the new software. The cephalometric software was designed using Microsoft Visual C++ program in Windows XP. Measurements made with the new software were compared with those of Dolphin software on both series of cephalograms. The validity and reliability were tested using intra-class correlation coefficient. Calculations showed a very high correlation between the results of the Iranian cephalometric analysis software and Dolphin. This confirms the validity and optimal efficacy of the newly designed software (ICC 0.570-1.0). According to our results, the newly designed software has acceptable validity and reliability and can be used for orthodontic diagnosis, treatment planning and assessment of treatment outcome.

  5. Assessing the reliability of FTIR spectroscopy measurements and validity of bioelectrical impedance analysis as a surrogate measure of body composition among children and adolescents aged 8-19 years attending schools in Kampala, Uganda.

    PubMed

    Ndagire, Catherine T; Muyonga, John H; Isabirye, Dan; Odur, Benard; Somda, Serge M A; Bukenya, Richard; Andrade, Juan E; Nakimbugwe, Dorothy

    2018-06-04

    Accurate measurement of body composition in children and adolescents is important as the quantities of fat and fat-free mass have implications for health risk. The objectives of the present study were: to determine the reliability of Fourier Transform Infrared spectroscopy (FTIR) measurements and; compare the Fat Mass (FM), Fat Free Mass (FFM) and body fat percentage (%BF) values determined by bioelectrical impedance analysis (BIA) to those determined by deuterium dilution method (DDM) to identify correlations and agreement between the two methods. A cross-sectional study was conducted among 203 children and adolescents aged 8-19 years attending schools in Kampala city, Uganda. Pearson product-moment correlation at 5% significance level was considered for assessing correlations. Bland Altman analysis was used to examine the agreement between of FTIR measurements and between estimates by DDM and BIA.. Reliability of measurements was determined by Cronbach's alpha. There was good agreement between the in vivo D 2 O saliva enrichment measurements at 3 and 4 h among the studied age groups based on Bland-Altman plots. Cronbach's alpha revealed that measurements of D 2 O saliva enrichment had very good reliability. For children and young adolescents, DDM and BIA gave similar estimates of FFM, FM, and %BF. Among older adolescents, BIA significantly over-estimated FFM and significantly under-estimated FM and %BF compared to estimates by DDM. The correlation between FFM, FM and %BF estimates by DDM and BIA was high and significant among young and older adolescents and for FFM among children. Reliability of the FTIR spectroscopy measurements was very good among the studied population. BIA is suitable for assessing body composition among children (8-9 years) and young adolescents (10-14 years) but not among older adolescents (15-19 years) in Uganda. The body composition measurements of older adolescents determined by DDM can be predicted using those provided by BIA using population-specific regression equations.

  6. A Real-World Setting Study: Which Glucose Meter Could Be the Best for POCT Use? An Easy and Applicable Protocol During the Hospital Routine.

    PubMed

    Mancini, Alessio; Esposto, Giampaolo; Manfrini, Silvana; Rilli, Silvia; Tinti, Gessica; Carta, Giuseppe; Petrolati, Laura; Vidali, Matteo; Barocci, Simone

    2018-05-01

    The aim of this retrospective study is to evaluate the reliability and robustness of six glucose meters for point-of-care testing in our wards using a brand-new protocol. During a 30-days study period a total of 50 diabetes patients were subjected to venous blood sampling and glucose meter blood analysis. The results of six glucose meters were compared with our laboratory reference assay. GlucoMen Plus (Menarini) with the 82% of acceptable results was the most robust glucose meter. Even if the Passing-Bablok analysis demonstrates the presence of constant systematic errors and the Bland-Altman test highlighted a possible overestimation, the surveillance error grid analysis showed that this glucose meter can be used safely. We proved that portable glucose meters are not always reliable in routinely clinical settings.

  7. Learning from Trending, Precursor Analysis, and System Failures

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Youngblood, R. W.; Duffey, R. B.

    2015-11-01

    Models of reliability growth relate current system unreliability to currently accumulated experience. But “experience” comes in different forms. Looking back after a major accident, one is sometimes able to identify previous events or measurable performance trends that were, in some sense, signaling the potential for that major accident: potential that could have been recognized and acted upon, but was not recognized until the accident occurred. This could be a previously unrecognized cause of accidents, or underestimation of the likelihood that a recognized potential cause would actually operate. Despite improvements in the state of practice of modeling of risk and reliability,more » operational experience still has a great deal to teach us, and work has been going on in several industries to try to do a better job of learning from experience before major accidents occur. It is not enough to say that we should review operating experience; there is too much “experience” for such general advice to be considered practical. The paper discusses the following: 1. The challenge of deciding what to focus on in analysis of operating experience. 2. Comparing what different models of learning and reliability growth imply about trending and precursor analysis.« less

  8. Validation of the Dementia Care Assessment Packet-Instrumental Activities of Daily Living

    PubMed Central

    Lee, Seok Bum; Park, Jeong Ran; Yoo, Jeong-Hwa; Park, Joon Hyuk; Lee, Jung Jae; Yoon, Jong Chul; Jhoo, Jin Hyeong; Lee, Dong Young; Woo, Jong Inn; Han, Ji Won; Huh, Yoonseok; Kim, Tae Hui

    2013-01-01

    Objective We aimed to evaluate the psychometric properties of the IADL measure included in the Dementia Care Assessment Packet (DCAP-IADL) in dementia patients. Methods The study involved 112 dementia patients and 546 controls. The DCAP-IADL was scored in two ways: observed score (OS) and predicted score (PS). The reliability of the DCAP-IADL was evaluated by testing its internal consistency, inter-rater reliability and test-retest reliability. Discriminant validity was evaluated by comparing the mean OS and PS between dementia patients and controls by ANCOVA. Pearson or Spearman correlation analysis was performed with other instruments to assess concurrent validity. Receiver operating characteristics curve analysis was performed to examine diagnostic accuracy. Results Chronbach's α coefficients of the DCAP-IADL were above 0.7. The values in dementia patients were much higher (OS=0.917, PS=0.927), indicating excellent degrees of internal consistency. Inter-rater reliabilities and test-retest reliabilities were statistically significant (p<0.05). PS exhibited higher reliabilities than OS. The mean OS and PS of dementia patients were significantly higher than those of the non-demented group after controlling for age, sex and education level. The DCAP-IADL was significantly correlated with other IADL instruments and MMSE-KC (p<0.001). Areas under the curves of the DCAP-IADL were above 0.9. Conclusion The DCAP-IADL is a reliable and valid instrument for evaluating instrumental ability of daily living for the elderly, and may also be useful for screening dementia. Moreover, administering PS may enable the DCAP-IADL to overcome the differences in gender, culture and life style that hinders accurate evaluation of the elderly in previous IADL instruments. PMID:24302946

  9. Validity and reliability of the persian version of templer death anxiety scale in family caregivers of cancer patients.

    PubMed

    Soleimani, Mohammad Ali; Bahrami, Nasim; Yaghoobzadeh, Ameneh; Banihashemi, Hedieh; Nia, Hamid Sharif; Haghdoost, Ali Akbar

    2016-01-01

    Due to increasing recognition of the importance of death anxiety for understanding human nature, it is important that researchers who investigate death anxiety have reliable and valid methodology to measure. The purpose of this study was to evaluate the validity and reliability of the Persian version of Templer Death Anxiety Scale (TDAS) in family caregivers of cancer patients. A sample of 326 caregivers of cancer patients completed a 15-item questionnaire. Principal components analysis (PCA) followed by a varimax rotation was used to assess factor structure of the DAS. The construct validity of the scale was assessed using exploratory and confirmatory factor analyses. Convergent and discriminant validity were also examined. Reliability was assessed with Cronbach's alpha coefficients and construction reliability. Based on the results of the PCA and consideration of the meaning of our items, a three-factor solution, explaining 60.38% of the variance, was identified. A confirmatory factor analysis (CFA) then supported the adequacy of the three-domain structure of the DAS. Goodness-of-fit indices showed an acceptable fit overall with the full model {χ(2)(df) = 262.32 (61), χ(2)/df = 2.04 [adjusted goodness of fit index (AGFI) = 0.922, parsimonious comparative fit index (PCFI) = 0.703, normed fit Index (NFI) = 0.912, CMIN/DF = 2.048, root mean square error of approximation (RMSEA) = 0.055]}. Convergent and discriminant validity were shown with construct fulfilled. The Cronbach's alpha and construct reliability were greater than 0.70. The findings show that the Persian version of the TDAS has a three-factor structure and acceptable validity and reliability.

  10. Evaluation of Reliability Coefficients for Two-Level Models via Latent Variable Analysis

    ERIC Educational Resources Information Center

    Raykov, Tenko; Penev, Spiridon

    2010-01-01

    A latent variable analysis procedure for evaluation of reliability coefficients for 2-level models is outlined. The method provides point and interval estimates of group means' reliability, overall reliability of means, and conditional reliability. In addition, the approach can be used to test simple hypotheses about these parameters. The…

  11. Counting pollen grains using readily available, free image processing and analysis software.

    PubMed

    Costa, Clayton M; Yang, Suann

    2009-10-01

    Although many methods exist for quantifying the number of pollen grains in a sample, there are few standard methods that are user-friendly, inexpensive and reliable. The present contribution describes a new method of counting pollen using readily available, free image processing and analysis software. Pollen was collected from anthers of two species, Carduus acanthoides and C. nutans (Asteraceae), then illuminated on slides and digitally photographed through a stereomicroscope. Using ImageJ (NIH), these digital images were processed to remove noise and sharpen individual pollen grains, then analysed to obtain a reliable total count of the number of grains present in the image. A macro was developed to analyse multiple images together. To assess the accuracy and consistency of pollen counting by ImageJ analysis, counts were compared with those made by the human eye. Image analysis produced pollen counts in 60 s or less per image, considerably faster than counting with the human eye (5-68 min). In addition, counts produced with the ImageJ procedure were similar to those obtained by eye. Because count parameters are adjustable, this image analysis protocol may be used for many other plant species. Thus, the method provides a quick, inexpensive and reliable solution to counting pollen from digital images, not only reducing the chance of error but also substantially lowering labour requirements.

  12. Psychometric Analysis and Qualitative Review of an Outpatient Radiology-Specific Patient Satisfaction Survey: A Call for Collaboration in Validating a Survey Instrument.

    PubMed

    Dibble, Elizabeth H; Baird, Grayson L; Swenson, David W; Healey, Terrance T

    2017-10-01

    The aim of this study was to perform a psychometric analysis of the constructs and reliability of an outpatient radiology-specific patient satisfaction survey and identify factors that drive patient experience so that radiology practices can improve the quality of their diagnostic imaging services. This retrospective study examined responses to eight patient satisfaction questions from a survey originally developed by a nascent marketing team and then administered at five outpatient imaging centers from January 7, 2013, to November 11, 2015. Patients' responses were reviewed to identify factors that affected patient experience, and a psychometric analysis of the survey instrument itself was performed, including exploratory factor analyses and reliability testing. Patient responses were compared among sites, examination types, and questions. Free-text comments were qualitatively categorized and compared by examination type. In total, 6,512 surveys were completed among 137,059 patient encounters. Using exploratory factor analyses of the eight survey questions, three relevant patient experience constructs were derived: (1) front office experience, (2) intake experience, and (3) examination experience. Overall, good scale reliability was observed. Perceived quality of care had the most positive ratings; wait time had the most nonpositive ratings. Of 2,024 free-text comments, 1,859 were positive (most pertaining to staff), and 155 were negative (most pertaining to convenience). MRI patients were most likely to share negative comments, typically regarding the examination experience itself. Psychometric analysis of a patient survey derived three core patient experience constructs: front office experience, intake experience, and examination experience. The survey indicates the need to decrease wait times, streamline the registration process, and improve patient comfort during MRI examinations. Copyright © 2017 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  13. A single-loop optimization method for reliability analysis with second order uncertainty

    NASA Astrophysics Data System (ADS)

    Xie, Shaojun; Pan, Baisong; Du, Xiaoping

    2015-08-01

    Reliability analysis may involve random variables and interval variables. In addition, some of the random variables may have interval distribution parameters owing to limited information. This kind of uncertainty is called second order uncertainty. This article develops an efficient reliability method for problems involving the three aforementioned types of uncertain input variables. The analysis produces the maximum and minimum reliability and is computationally demanding because two loops are needed: a reliability analysis loop with respect to random variables and an interval analysis loop for extreme responses with respect to interval variables. The first order reliability method and nonlinear optimization are used for the two loops, respectively. For computational efficiency, the two loops are combined into a single loop by treating the Karush-Kuhn-Tucker (KKT) optimal conditions of the interval analysis as constraints. Three examples are presented to demonstrate the proposed method.

  14. Multivariate pattern analysis for MEG: A comparison of dissimilarity measures.

    PubMed

    Guggenmos, Matthias; Sterzer, Philipp; Cichy, Radoslaw Martin

    2018-06-01

    Multivariate pattern analysis (MVPA) methods such as decoding and representational similarity analysis (RSA) are growing rapidly in popularity for the analysis of magnetoencephalography (MEG) data. However, little is known about the relative performance and characteristics of the specific dissimilarity measures used to describe differences between evoked activation patterns. Here we used a multisession MEG data set to qualitatively characterize a range of dissimilarity measures and to quantitatively compare them with respect to decoding accuracy (for decoding) and between-session reliability of representational dissimilarity matrices (for RSA). We tested dissimilarity measures from a range of classifiers (Linear Discriminant Analysis - LDA, Support Vector Machine - SVM, Weighted Robust Distance - WeiRD, Gaussian Naïve Bayes - GNB) and distances (Euclidean distance, Pearson correlation). In addition, we evaluated three key processing choices: 1) preprocessing (noise normalisation, removal of the pattern mean), 2) weighting decoding accuracies by decision values, and 3) computing distances in three different partitioning schemes (non-cross-validated, cross-validated, within-class-corrected). Four main conclusions emerged from our results. First, appropriate multivariate noise normalization substantially improved decoding accuracies and the reliability of dissimilarity measures. Second, LDA, SVM and WeiRD yielded high peak decoding accuracies and nearly identical time courses. Third, while using decoding accuracies for RSA was markedly less reliable than continuous distances, this disadvantage was ameliorated by decision-value-weighting of decoding accuracies. Fourth, the cross-validated Euclidean distance provided unbiased distance estimates and highly replicable representational dissimilarity matrices. Overall, we strongly advise the use of multivariate noise normalisation as a general preprocessing step, recommend LDA, SVM and WeiRD as classifiers for decoding and highlight the cross-validated Euclidean distance as a reliable and unbiased default choice for RSA. Copyright © 2018 Elsevier Inc. All rights reserved.

  15. Ultrasound estimates of muscle quality in older adults: reliability and comparison of Photoshop and ImageJ for the grayscale analysis of muscle echogenicity

    PubMed Central

    Seamon, Bryant A.; Teixeira, Carla; Ismail, Catheeja

    2016-01-01

    Background. Quantitative diagnostic ultrasound imaging has been proposed as a method of estimating muscle quality using measures of echogenicity. The Rectangular Marquee Tool (RMT) and the Free Hand Tool (FHT) are two types of editing features used in Photoshop and ImageJ for determining a region of interest (ROI) within an ultrasound image. The primary objective of this study is to determine the intrarater and interrater reliability of Photoshop and ImageJ for the estimate of muscle tissue echogenicity in older adults via grayscale histogram analysis. The secondary objective is to compare the mean grayscale values obtained using both the RMT and FHT methods across both image analysis platforms. Methods. This cross-sectional observational study features 18 community-dwelling men (age = 61.5 ± 2.32 years). Longitudinal views of the rectus femoris were captured using B-mode ultrasound. The ROI for each scan was selected by 2 examiners using the RMT and FHT methods from each software program. Their reliability is assessed using intraclass correlation coefficients (ICCs) and the standard error of the measurement (SEM). Measurement agreement for these values is depicted using Bland-Altman plots. A paired t-test is used to determine mean differences in echogenicity expressed as grayscale values using the RMT and FHT methods to select the post-image acquisition ROI. The degree of association among ROI selection methods and image analysis platforms is analyzed using the coefficient of determination (R2). Results. The raters demonstrated excellent intrarater and interrater reliability using the RMT and FHT methods across both platforms (lower bound 95% CI ICC = .97–.99, p < .001). Mean differences between the echogenicity estimates obtained with the RMT and FHT methods was .87 grayscale levels (95% CI [.54–1.21], p < .0001) using data obtained with both programs. The SEM for Photoshop was .97 and 1.05 grayscale levels when using the RMT and FHT ROI selection methods, respectively. Comparatively, the SEM values were .72 and .81 grayscale levels, respectively, when using the RMT and FHT ROI selection methods in ImageJ. Uniform coefficients of determination (R2 = .96–.99, p < .001) indicate strong positive associations among the grayscale histogram analysis measurement conditions independent of the ROI selection methods and imaging platform. Conclusion. Our method for evaluating muscle echogenicity demonstrated a high degree of intrarater and interrater reliability using both the RMT and FHT methods across 2 common image analysis platforms. The minimal measurement error exhibited by the examiners demonstrates that the ROI selection methods used with Photoshop and ImageJ are suitable for the post-acquisition image analysis of tissue echogenicity in older adults. PMID:26925339

  16. Failure rate analysis of Goddard Space Flight Center spacecraft performance during orbital life

    NASA Technical Reports Server (NTRS)

    Norris, H. P.; Timmins, A. R.

    1976-01-01

    Space life performance data on 57 Goddard Space Flight Center spacecraft are analyzed from the standpoint of determining an appropriate reliability model and the associated reliability parameters. Data from published NASA reports, which cover the space performance of GSFC spacecraft launched in the 1960-1970 decade, form the basis of the analyses. The results of the analyses show that the time distribution of 449 malfunctions, of which 248 were classified as failures (not necessarily catastrophic), follow a reliability growth pattern that can be described with either the Duane model or a Weibull distribution. The advantages of both mathematical models are used in order to: identify space failure rates, observe chronological trends, and compare failure rates with those experienced during the prelaunch environmental tests of the flight model spacecraft.

  17. Preliminary design and analysis of an advanced rotorcraft transmission

    NASA Technical Reports Server (NTRS)

    Henry, Z. S.

    1990-01-01

    Future rotorcraft transmissions of the 1990s and beyond the year 2000 require the incorporation of key emerging material and component technologies using advanced and innovative design practices in order to meet the requirements for a reduced weight-to-power ratio, a decreased noise level, and a substantially increased reliability. The specific goals for future rotocraft transmissions when compared with current state-of-the-art transmissions are a 25 percent weight reduction, a 10-dB reduction in the transmitted noise level, and a system reliability of 5000 hours mean-time-between-removal for the transmission. This paper presents the results of the design studies conducted to meet the stated goals for an advanced rotorcraft transmission. These design studies include system configuration, planetary gear train selection, and reliability prediction methods.

  18. Chapter 15: Reliability of Wind Turbines

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sheng, Shuangwen; O'Connor, Ryan

    The global wind industry has witnessed exciting developments in recent years. The future will be even brighter with further reductions in capital and operation and maintenance costs, which can be accomplished with improved turbine reliability, especially when turbines are installed offshore. One opportunity for the industry to improve wind turbine reliability is through the exploration of reliability engineering life data analysis based on readily available data or maintenance records collected at typical wind plants. If adopted and conducted appropriately, these analyses can quickly save operation and maintenance costs in a potentially impactful manner. This chapter discusses wind turbine reliability bymore » highlighting the methodology of reliability engineering life data analysis. It first briefly discusses fundamentals for wind turbine reliability and the current industry status. Then, the reliability engineering method for life analysis, including data collection, model development, and forecasting, is presented in detail and illustrated through two case studies. The chapter concludes with some remarks on potential opportunities to improve wind turbine reliability. An owner and operator's perspective is taken and mechanical components are used to exemplify the potential benefits of reliability engineering analysis to improve wind turbine reliability and availability.« less

  19. A Comparison of Reliability and Construct Validity between the Original and Revised Versions of the Rosenberg Self-Esteem Scale

    PubMed Central

    Nahathai, Wongpakaran

    2012-01-01

    Objective The Rosenberg Self-Esteem Scale (RSES) is a widely used instrument that has been tested for reliability and validity in many settings; however, some negative-worded items appear to have caused it to reveal low reliability in a number of studies. In this study, we revised one negative item that had previously (from the previous studies) produced the worst outcome in terms of the structure of the scale, then re-analyzed the new version for its reliability and construct validity, comparing it to the original version with respect to fit indices. Methods In total, 851 students from Chiang Mai University (mean age: 19.51±1.7, 57% of whom were female), participated in this study. Of these, 664 students completed the Thai version of the original RSES - containing five positively worded and five negatively worded items, while 187 students used the revised version containing six positively worded and four negatively worded items. Confirmatory factor analysis was applied, using a uni-dimensional model with method effects and a correlated uniqueness approach. Results The revised version showed the same level of reliability (good) as the original, but yielded a better model fit. The revised RSES demonstrated excellent fit statistics, with χ2=29.19 (df=19, n=187, p=0.063), GFI=0.970, TFI=0.969, NFI=0.964, CFI=0.987, SRMR=0.040 and RMSEA=0.054. Conclusion The revised version of the Thai RSES demonstrated an equivalent level of reliability but a better construct validity when compared to the original. PMID:22396685

  20. A comparison of reliability and construct validity between the original and revised versions of the Rosenberg Self-Esteem Scale.

    PubMed

    Wongpakaran, Tinakon; Tinakon, Wongpakaran; Wongpakaran, Nahathai; Nahathai, Wongpakaran

    2012-03-01

    The Rosenberg Self-Esteem Scale (RSES) is a widely used instrument that has been tested for reliability and validity in many settings; however, some negative-worded items appear to have caused it to reveal low reliability in a number of studies. In this study, we revised one negative item that had previously (from the previous studies) produced the worst outcome in terms of the structure of the scale, then re-analyzed the new version for its reliability and construct validity, comparing it to the original version with respect to fit indices. In total, 851 students from Chiang Mai University (mean age: 19.51±1.7, 57% of whom were female), participated in this study. Of these, 664 students completed the Thai version of the original RSES - containing five positively worded and five negatively worded items, while 187 students used the revised version containing six positively worded and four negatively worded items. Confirmatory factor analysis was applied, using a uni-dimensional model with method effects and a correlated uniqueness approach. The revised version showed the same level of reliability (good) as the original, but yielded a better model fit. The revised RSES demonstrated excellent fit statistics, with χ²=29.19 (df=19, n=187, p=0.063), GFI=0.970, TFI=0.969, NFI=0.964, CFI=0.987, SRMR=0.040 and RMSEA=0.054. The revised version of the Thai RSES demonstrated an equivalent level of reliability but a better construct validity when compared to the original.

  1. Measurement Invariance of the UTAUT Constructs in the Caribbean

    ERIC Educational Resources Information Center

    Thomas, Troy D.; Singh, Lenandlar; Gaffar, Kemuel; Thakur, Dhanaraj; Jackman, Grace-Ann; Thomas, Michael; Gajraj, Roger; Allen, Claudine; Tooma, Keron

    2014-01-01

    This article employs confirmatory factor analysis to evaluate the factorial validity and the cross-national comparability of the UTAUT constructs with respect to mobile learning in higher education in four Caribbean countries. Except for the measurement of one factor, the UTAUT constructs exhibit adequate reliability and validity. Though full…

  2. Time-frequency analysis of phonocardiogram signals using wavelet transform: a comparative study.

    PubMed

    Ergen, Burhan; Tatar, Yetkin; Gulcur, Halil Ozcan

    2012-01-01

    Analysis of phonocardiogram (PCG) signals provides a non-invasive means to determine the abnormalities caused by cardiovascular system pathology. In general, time-frequency representation (TFR) methods are used to study the PCG signal because it is one of the non-stationary bio-signals. The continuous wavelet transform (CWT) is especially suitable for the analysis of non-stationary signals and to obtain the TFR, due to its high resolution, both in time and in frequency and has recently become a favourite tool. It decomposes a signal in terms of elementary contributions called wavelets, which are shifted and dilated copies of a fixed mother wavelet function, and yields a joint TFR. Although the basic characteristics of the wavelets are similar, each type of the wavelets produces a different TFR. In this study, eight real types of the most known wavelets are examined on typical PCG signals indicating heart abnormalities in order to determine the best wavelet to obtain a reliable TFR. For this purpose, the wavelet energy and frequency spectrum estimations based on the CWT and the spectra of the chosen wavelets were compared with the energy distribution and the autoregressive frequency spectra in order to determine the most suitable wavelet. The results show that Morlet wavelet is the most reliable wavelet for the time-frequency analysis of PCG signals.

  3. A Most Probable Point-Based Method for Reliability Analysis, Sensitivity Analysis and Design Optimization

    NASA Technical Reports Server (NTRS)

    Hou, Gene J.-W; Newman, Perry A. (Technical Monitor)

    2004-01-01

    A major step in a most probable point (MPP)-based method for reliability analysis is to determine the MPP. This is usually accomplished by using an optimization search algorithm. The minimum distance associated with the MPP provides a measurement of safety probability, which can be obtained by approximate probability integration methods such as FORM or SORM. The reliability sensitivity equations are derived first in this paper, based on the derivatives of the optimal solution. Examples are provided later to demonstrate the use of these derivatives for better reliability analysis and reliability-based design optimization (RBDO).

  4. Organize to manage reliability

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ricketts, R.

    An analysis of maintenance costs in hydrocarbon processing industry (HPI) plants has revealed that attitudes and practices of personnel are the major single bottom line factor. In reaching this conclusion, Solomon Associates examined comparative analysis of plant records over the past decade. The authors learned that there was a wide range of performance independent of refinery age, capacity, processing complexity, and location. Facilities of all extremes in these attributes are included in both high-cost and low-cost categories. Those in the lowest quartile of performance posted twice the resource consumption as the best quartile. Furthermore, there was almost no similarity betweenmore » refineries within a single company. The paper discusses cost versus availability, maintenance spending, two organizational approaches used (repair focused and reliability focused), and organizational style and structure.« less

  5. Microbial Diagnostic Microarrays for the Detection and Typing of Food- and Water-Borne (Bacterial) Pathogens

    PubMed Central

    Kostić, Tanja; Sessitsch, Angela

    2011-01-01

    Reliable and sensitive pathogen detection in clinical and environmental (including food and water) samples is of greatest importance for public health. Standard microbiological methods have several limitations and improved alternatives are needed. Most important requirements for reliable analysis include: (i) specificity; (ii) sensitivity; (iii) multiplexing potential; (iv) robustness; (v) speed; (vi) automation potential; and (vii) low cost. Microarray technology can, through its very nature, fulfill many of these requirements directly and the remaining challenges have been tackled. In this review, we attempt to compare performance characteristics of the microbial diagnostic microarrays developed for the detection and typing of food and water pathogens, and discuss limitations, points still to be addressed and issues specific for the analysis of food, water and environmental samples. PMID:27605332

  6. Reliability verification of vehicle speed estimate method in forensic videos.

    PubMed

    Kim, Jong-Hyuk; Oh, Won-Taek; Choi, Ji-Hun; Park, Jong-Chan

    2018-06-01

    In various types of traffic accidents, including car-to-car crash, vehicle-pedestrian collision, and hit-and-run accident, driver overspeed is one of the critical issues of traffic accident analysis. Hence, analysis of vehicle speed at the moment of accident is necessary. The present article proposes a vehicle speed estimate method (VSEM) applying a virtual plane and a virtual reference line to a forensic video. The reliability of the VSEM was verified by comparing the results obtained by applying the VSEM to videos from a test vehicle driving with a global positioning system (GPS)-based Vbox speed. The VSEM verified by these procedures was applied to real traffic accident examples to evaluate the usability of the VSEM. Copyright © 2018 Elsevier B.V. All rights reserved.

  7. One-year test-retest reliability of intrinsic connectivity network fMRI in older adults

    PubMed Central

    Guo, Cong C.; Kurth, Florian; Zhou, Juan; Mayer, Emeran A.; Eickhoff, Simon B; Kramer, Joel H.; Seeley, William W.

    2014-01-01

    “Resting-state” or task-free fMRI can assess intrinsic connectivity network (ICN) integrity in health and disease, suggesting a potential for use of these methods as disease-monitoring biomarkers. Numerous analytical options are available, including model-driven ROI-based correlation analysis and model-free, independent component analysis (ICA). High test-retest reliability will be a necessary feature of a successful ICN biomarker, yet available reliability data remains limited. Here, we examined ICN fMRI test-retest reliability in 24 healthy older subjects scanned roughly one year apart. We focused on the salience network, a disease-relevant ICN not previously subjected to reliability analysis. Most ICN analytical methods proved reliable (intraclass coefficients > 0.4) and could be further improved by wavelet analysis. Seed-based ROI correlation analysis showed high map-wise reliability, whereas graph theoretical measures and temporal concatenation group ICA produced the most reliable individual unit-wise outcomes. Including global signal regression in ROI-based correlation analyses reduced reliability. Our study provides a direct comparison between the most commonly used ICN fMRI methods and potential guidelines for measuring intrinsic connectivity in aging control and patient populations over time. PMID:22446491

  8. Comparative research of redundant strap down inertial navigation system based on different configuration schemes

    NASA Astrophysics Data System (ADS)

    Yu, Yuting; Cheng, Ming

    2018-05-01

    Aiming at various configuration scheme and inertial measurement units of Strapdown Inertial Navigation System, selected tetrahedron skew configuration and coaxial orthogonal configuration by nine low cost IMU to build system. Calculation and simulation the performance index, reliability and fault diagnosis ability of the navigation system. Analysis shows that the reliability and reconfiguration scheme of skew configuration is superior to the orthogonal configuration scheme, while the performance index and fault diagnosis ability of the system are similar. The work in this paper provides a strong reference for the selection of engineering applications.

  9. TDRSS telecommunications system, PN code analysis

    NASA Technical Reports Server (NTRS)

    Dixon, R.; Gold, R.; Kaiser, F.

    1976-01-01

    The pseudo noise (PN) codes required to support the TDRSS telecommunications services are analyzed and the impact of alternate coding techniques on the user transponder equipment, the TDRSS equipment, and all factors that contribute to the acquisition and performance of these telecommunication services is assessed. Possible alternatives to the currently proposed hybrid FH/direct sequence acquisition procedures are considered and compared relative to acquisition time, implementation complexity, operational reliability, and cost. The hybrid FH/direct sequence technique is analyzed and rejected in favor of a recommended approach which minimizes acquisition time and user transponder complexity while maximizing probability of acquisition and overall link reliability.

  10. [Research on the reliability and validity of postural workload assessment method and the relation to work-related musculoskeletal disorders of workers].

    PubMed

    Qin, D L; Jin, X N; Wang, S J; Wang, J J; Mamat, N; Wang, F J; Wang, Y; Shen, Z A; Sheng, L G; Forsman, M; Yang, L Y; Wang, S; Zhang, Z B; He, L H

    2018-06-18

    To form a new assessment method to evaluate postural workload comprehensively analyzing the dynamic and static postural workload for workers during their work process to analyze the reliability and validity, and to study the relation between workers' postural workload and work-related musculoskeletal disorders (WMSDs). In the study, 844 workers from electronic and railway vehicle manufacturing factories were selected as subjects investigated by using the China Musculoskeletal Questionnaire (CMQ) to form the postural workload comprehensive assessment method. The Cronbach's α, cluster analysis and factor analysis were used to assess the reliability and validity of the new assessment method. Non-conditional Logistic regression was used to analyze the relation between workers' postural workload and WMSDs. Reliability of the assessment method for postural workload: internal consistency analysis results showed that Cronbach's α was 0.934 and the results of split-half reliability indicated that Spearman-Brown coefficient was 0.881 and the correlation coefficient between the first part and the second was 0.787. Validity of the assessment method for postural workload: the results of cluster analysis indicated that square Euclidean distance between dynamic and static postural workload assessment in the same part or work posture was the shortest. The results of factor analysis showed that 2 components were extracted and the cumulative percentage of variance achieved 65.604%. The postural workload score of the different occupational workers showed significant difference (P<0.05) by covariance analysis. The results of nonconditional Logistic regression indicated that alcohol intake (OR=2.141, 95%CI 1.337-3.428) and obesity (OR=3.408, 95%CI 1.629-7.130) were risk factors for WMSDs. The risk for WMSDs would rise as workers' postural workload rose (OR=1.035, 95%CI 1.022-1.048). There was significant different risk for WMSDs in the different groups of workers distinguished by work type, gender and age. Female workers exhibited a higher prevalence for WMSDs (OR=2.626, 95%CI 1.414-4.879) and workers between 30-40 years of age (OR=1.909, 95%CI 1.237-2.946) as compared with those under 30. This method for comprehensively assessing postural workload is reliable and effective when used in assembling workers, and there is certain relation between the postural workload and WMSDs.

  11. Periodic component analysis as a spatial filter for SSVEP-based brain-computer interface.

    PubMed

    Kiran Kumar, G R; Reddy, M Ramasubba

    2018-06-08

    Traditional Spatial filters used for steady-state visual evoked potential (SSVEP) extraction such as minimum energy combination (MEC) require the estimation of the background electroencephalogram (EEG) noise components. Even though this leads to improved performance in low signal to noise ratio (SNR) conditions, it makes such algorithms slow compared to the standard detection methods like canonical correlation analysis (CCA) due to the additional computational cost. In this paper, Periodic component analysis (πCA) is presented as an alternative spatial filtering approach to extract the SSVEP component effectively without involving extensive modelling of the noise. The πCA can separate out components corresponding to a given frequency of interest from the background electroencephalogram (EEG) by capturing the temporal information and does not generalize SSVEP based on rigid templates. Data from ten test subjects were used to evaluate the proposed method and the results demonstrate that the periodic component analysis acts as a reliable spatial filter for SSVEP extraction. Statistical tests were performed to validate the results. The experimental results show that πCA provides significant improvement in accuracy compared to standard CCA and MEC in low SNR conditions. The results demonstrate that πCA provides better detection accuracy compared to CCA and on par with that of MEC at a lower computational cost. Hence πCA is a reliable and efficient alternative detection algorithm for SSVEP based brain-computer interface (BCI). Copyright © 2018. Published by Elsevier B.V.

  12. Modified Right Heart Contrast Echocardiography Versus Traditional Method in Diagnosis of Right-to-Left Shunt: A Comparative Study.

    PubMed

    Wang, Yi; Zeng, Jie; Yin, Lixue; Zhang, Mei; Hou, Dailun

    2016-01-01

    The purpose of this study was to evaluate the reliability, effectiveness, and safety of modified right heart contrast transthoracic echocardiography (cTTE) in comparison with the traditional method. We performed a modified right heart cTTE using saline mixed with a small sample of patient's own blood. Samples were agitated with varying intensity. This study protocol involved microscopic analysis and patient evaluation. 1. Microscopic analysis: After two contrast samples had been agitated 10 or 20 times, they underwent a comparison of bubble size, bubble number, and red blood cell morphology. 2. Patient analysis: 40 patients with suspected RLS (right- to-left shunt) were enrolled. All patients underwent right heart contrast echocardiography. Oxygen saturation, transit time and duration, presence of RLS, change in indirect bilirubin and urobilinogen concentrations were compared afterward. Modified method generated more bubbles (P<0.05), but the differences in bubble size were not significant (P>0.05). Twenty-four patients were diagnosed with RLS (60%) using the modified method compared to 16 patients (40%) with the traditional method. The transit time of ASb20 group was the shortest (P<0.05). However, the duration time in this group was much longer (P<0.05). Also, in semi-quantitative analysis mean rank of RLS was higher after injecting the modified contrast agent agitated 20 times (P<0.05). Modified right heart contrast echocardiography is a reliable, effective and safe method of detecting cardiovascular RLS.

  13. NASA Applications and Lessons Learned in Reliability Engineering

    NASA Technical Reports Server (NTRS)

    Safie, Fayssal M.; Fuller, Raymond P.

    2011-01-01

    Since the Shuttle Challenger accident in 1986, communities across NASA have been developing and extensively using quantitative reliability and risk assessment methods in their decision making process. This paper discusses several reliability engineering applications that NASA has used over the year to support the design, development, and operation of critical space flight hardware. Specifically, the paper discusses several reliability engineering applications used by NASA in areas such as risk management, inspection policies, components upgrades, reliability growth, integrated failure analysis, and physics based probabilistic engineering analysis. In each of these areas, the paper provides a brief discussion of a case study to demonstrate the value added and the criticality of reliability engineering in supporting NASA project and program decisions to fly safely. Examples of these case studies discussed are reliability based life limit extension of Shuttle Space Main Engine (SSME) hardware, Reliability based inspection policies for Auxiliary Power Unit (APU) turbine disc, probabilistic structural engineering analysis for reliability prediction of the SSME alternate turbo-pump development, impact of ET foam reliability on the Space Shuttle System risk, and reliability based Space Shuttle upgrade for safety. Special attention is given in this paper to the physics based probabilistic engineering analysis applications and their critical role in evaluating the reliability of NASA development hardware including their potential use in a research and technology development environment.

  14. A reliability study on brain activation during active and passive arm movements supported by an MRI-compatible robot.

    PubMed

    Estévez, Natalia; Yu, Ningbo; Brügger, Mike; Villiger, Michael; Hepp-Reymond, Marie-Claude; Riener, Robert; Kollias, Spyros

    2014-11-01

    In neurorehabilitation, longitudinal assessment of arm movement related brain function in patients with motor disability is challenging due to variability in task performance. MRI-compatible robots monitor and control task performance, yielding more reliable evaluation of brain function over time. The main goals of the present study were first to define the brain network activated while performing active and passive elbow movements with an MRI-compatible arm robot (MaRIA) in healthy subjects, and second to test the reproducibility of this activation over time. For the fMRI analysis two models were compared. In model 1 movement onset and duration were included, whereas in model 2 force and range of motion were added to the analysis. Reliability of brain activation was tested with several statistical approaches applied on individual and group activation maps and on summary statistics. The activated network included mainly the primary motor cortex, primary and secondary somatosensory cortex, superior and inferior parietal cortex, medial and lateral premotor regions, and subcortical structures. Reliability analyses revealed robust activation for active movements with both fMRI models and all the statistical methods used. Imposed passive movements also elicited mainly robust brain activation for individual and group activation maps, and reliability was improved by including additional force and range of motion using model 2. These findings demonstrate that the use of robotic devices, such as MaRIA, can be useful to reliably assess arm movement related brain activation in longitudinal studies and may contribute in studies evaluating therapies and brain plasticity following injury in the nervous system.

  15. Reliability and validity of the Children's Fear Survey Schedule-Dental Subscale for Arabic-speaking children: a cross-sectional study.

    PubMed

    El-Housseiny, Azza A; Alsadat, Farah A; Alamoudi, Najlaa M; El Derwi, Douaa A; Farsi, Najat M; Attar, Moaz H; Andijani, Basil M

    2016-04-14

    Early recognition of dental fear is essential for the effective delivery of dental care. This study aimed to test the reliability and validity of the Arabic version of the Children's Fear Survey Schedule-Dental Subscale (CFSS-DS). A school-based sample of 1546 children was randomly recruited. The Arabic version of the CFSS-DS was completed by children during class time. The scale was tested for internal consistency and test-retest reliability. To test criterion validity, children's behavior was assessed using the Frankl scale during dental examination, and results were compared with children's CFSS-DS scores. To test the scale's construct validity, scores on "fear of going to the dentist soon" were correlated with CFSS-DS scores. Factor analysis was also used. The Arabic version of the CFSS-DS showed high reliability regarding both test-retest reliability (intraclass correlation = 0.83, p < 0.001) and internal consistency (Cronbach's α = 0.88). It showed good criterion validity: children with negative behavior had significantly higher fear scores (t = 13.67, p < 0.001). It also showed moderate construct validity (Spearman's rho correlation, r = 0.53, p < 0.001). Factor analysis identified the following factors: "fear of invasive dental procedures," "fear of less invasive dental procedures" and "fear of strangers." The Arabic version of the CFSS-DS is a reliable and valid measure of dental fear in Arabic-speaking children. Pediatric dentists and researchers may use this validated version of the CFSS-DS to measure dental fear in Arabic-speaking children.

  16. Bearing Procurement Analysis Method by Total Cost of Ownership Analysis and Reliability Prediction

    NASA Astrophysics Data System (ADS)

    Trusaji, Wildan; Akbar, Muhammad; Sukoyo; Irianto, Dradjad

    2018-03-01

    In making bearing procurement analysis, price and its reliability must be considered as decision criteria, since price determines the direct cost as acquisition cost and reliability of bearing determine the indirect cost such as maintenance cost. Despite the indirect cost is hard to identify and measured, it has high contribution to overall cost that will be incurred. So, the indirect cost of reliability must be considered when making bearing procurement analysis. This paper tries to explain bearing evaluation method with the total cost of ownership analysis to consider price and maintenance cost as decision criteria. Furthermore, since there is a lack of failure data when bearing evaluation phase is conducted, reliability prediction method is used to predict bearing reliability from its dynamic load rating parameter. With this method, bearing with a higher price but has higher reliability is preferable for long-term planning. But for short-term planning the cheaper one but has lower reliability is preferable. This contextuality can give rise to conflict between stakeholders. Thus, the planning horizon needs to be agreed by all stakeholder before making a procurement decision.

  17. Model of load balancing using reliable algorithm with multi-agent system

    NASA Astrophysics Data System (ADS)

    Afriansyah, M. F.; Somantri, M.; Riyadi, M. A.

    2017-04-01

    Massive technology development is linear with the growth of internet users which increase network traffic activity. It also increases load of the system. The usage of reliable algorithm and mobile agent in distributed load balancing is a viable solution to handle the load issue on a large-scale system. Mobile agent works to collect resource information and can migrate according to given task. We propose reliable load balancing algorithm using least time first byte (LFB) combined with information from the mobile agent. In system overview, the methodology consisted of defining identification system, specification requirements, network topology and design system infrastructure. The simulation method for simulated system was using 1800 request for 10 s from the user to the server and taking the data for analysis. Software simulation was based on Apache Jmeter by observing response time and reliability of each server and then compared it with existing method. Results of performed simulation show that the LFB method with mobile agent can perform load balancing with efficient systems to all backend server without bottleneck, low risk of server overload, and reliable.

  18. Measurement Properties of the NIH-Minimal Dataset Dutch Language Version in Patients With Chronic Low Back Pain.

    PubMed

    Boer, Annemarie; Dutmer, Alisa L; Schiphorst Preuper, Henrica R; van der Woude, Lucas H V; Stewart, Roy E; Deyo, Richard A; Reneman, Michiel F; Soer, Remko

    2017-10-01

    Validation study with cross-sectional and longitudinal measurements. To translate the US National Institutes of Health (NIH)-minimal dataset for clinical research on chronic low back pain into the Dutch language and to test its validity and reliability among people with chronic low back pain. The NIH developed a minimal dataset to encourage more complete and consistent reporting of clinical research and to be able to compare studies across countries in patients with low back pain. In the Netherlands, the NIH-minimal dataset has not been translated before and measurement properties are unknown. Cross-cultural validity was tested by a formal forward-backward translation. Structural validity was tested with exploratory factor analyses (comparative fit index, Tucker-Lewis index, and root mean square error of approximation). Hypothesis testing was performed to compare subscales of the NIH dataset with the Pain Disability Index and the EurQol-5D (Pearson correlation coefficients). Internal consistency was tested with Cronbach α and test-retest reliability at 2 weeks was calculated in a subsample of patients with Intraclass Correlation Coefficients and weighted Kappa (κω). In total, 452 patients were included of which 52 were included for the test-retest study. factor analysis for structural validity pointed into the direction of a seven-factor model (Cronbach α = 0.78). Factors and total score of the NIH-minimal dataset showed fair to good correlations with Pain Disability Index (r = 0.43-0.70) and EuroQol-5D (r = -0.41 to -0.64). Reliability: test-retest reliability per item showed substantial agreement (κω=0.65). Test-retest reliability per factor was moderate to good (Intraclass Correlation Coefficient = 0.71). The Dutch language version measurement properties of the NIH-minimal were satisfactory. N/A.

  19. Patient-specific 3D models created by 3D imaging system or bi-planar imaging coupled with Moiré-Fringe projections: a comparative study of accuracy and reliability on spinal curvatures and vertebral rotation data.

    PubMed

    Hocquelet, Arnaud; Cornelis, François; Jirot, Anna; Castaings, Laurent; de Sèze, Mathieu; Hauger, Olivier

    2016-10-01

    The aim of this study is to compare the accuracy and reliability of spinal curvatures and vertebral rotation data based on patient-specific 3D models created by 3D imaging system or by bi-planar imaging coupled with Moiré-Fringe projections. Sixty-two consecutive patients from a single institution were prospectively included. For each patient, frontal and sagittal calibrated low-dose bi-planar X-rays were performed and coupled simultaneously with an optical Moiré back surface-based technology. The 3D reconstructions of spine and pelvis were performed independently by one radiologist and one technician in radiology using two different semi-automatic methods using 3D radio-imaging system (method 1) or bi-planar imaging coupled with Moiré projections (method 2). Both methods were compared using Bland-Altman analysis, and reliability using intraclass correlation coefficient (ICC). ICC showed good to very good agreement. Between the two techniques, the maximum 95 % prediction limits was -4.9° degrees for the measurements of spinal coronal curves and less than 5° for other parameters. Inter-rater reliability was excellent for all parameters across both methods, except for axial rotation with method 2 for which ICC was fair. Method 1 was faster for reconstruction time than method 2 for both readers (13.4 vs. 20.7 min and 10.6 vs. 13.9 min; p = 0.0001). While a lower accuracy was observed for the evaluation of the axial rotation, bi-planar imaging coupled with Moiré-Fringe projections may be an accurate and reliable tool to perform 3D reconstructions of the spine and pelvis.

  20. Greater understanding of normal hip physical function may guide clinicians in providing targeted rehabilitation programmes.

    PubMed

    Kemp, Joanne L; Schache, Anthony G; Makdissi, Michael; Sims, Kevin J; Crossley, Kay M

    2013-07-01

    This study investigated tests of hip muscle strength and functional performance. The specific objectives were to: (i) establish intra- and inter-rater reliability; (ii) compare differences between dominant and non-dominant limbs; (iii) compare agonist and antagonist muscle strength ratios; (iv) compare differences between genders; and (v) examine relationships between hip muscle strength, baseline measures and functional performance. Reliability study and cross-sectional analysis of hip strength and functional performance. In healthy adults aged 18-50years, normalised hip muscle peak torque and functional performance were evaluated to: (i) establish intra-rater and inter-rater reliability; (ii) analyse differences between limbs, between antagonistic muscle groups and genders; and (iii) associations between strength and functional performance. Excellent reliability (intra-rater ICC=0.77-0.96; inter-rater ICC=0.82-0.95) was observed. No difference existed between dominant and non-dominant limbs. Differences in strength existed between antagonistic pairs of muscles: hip abduction was greater than adduction (p<0.001) and hip ER was greater than IR (p<0.001). Men had greater ER strength (p=0.006) and hop for distance (p<0.001) than women. Strong associations were observed between measures of hip muscle strength (except hip flexion) and age, height, and functional performance. Deficits in hip muscle strength or functional performance may influence hip pain. In order to provide targeted rehabilitation programmes to address patient-specific impairments, and determine when individuals are ready to return to physical activity, clinicians are increasingly utilising tests of hip strength and functional performance. This study provides a battery of reliable, clinically applicable tests which can be used for these purposes. Copyright © 2012 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  1. Reliability and Validity of a Japanese-language and Culturally Adapted Version of the Musculoskeletal Tumor Society Scoring System for the Lower Extremity.

    PubMed

    Iwata, Shintaro; Uehara, Kosuke; Ogura, Koichi; Akiyama, Toru; Shinoda, Yusuke; Yonemoto, Tsukasa; Kawai, Akira

    2016-09-01

    The Musculoskeletal Tumor Society (MSTS) scoring system is a widely used functional evaluation tool for patients treated for musculoskeletal tumors. Although the MSTS scoring system has been validated in English and Brazilian Portuguese, a Japanese version of the MSTS scoring system has not yet been validated. We sought to determine whether a Japanese-language translation of the MSTS scoring system for the lower extremity had (1) sufficient reliability and internal consistency, (2) adequate construct validity, and (3) reasonable criterion validity compared with the Toronto Extremity Salvage Score (TESS) and SF-36 using psychometric analysis. The Japanese version of the MSTS scoring system was developed using accepted guidelines, which included translation of the English version of the MSTS into Japanese by five native Japanese bilingual musculoskeletal oncology surgeons and integrated into one document. One hundred patients with a diagnosis of intermediate or malignant bone or soft tissue tumors located in the lower extremity and who had undergone tumor resection with or without reconstruction or amputation participated in this study. Reliability was evaluated by test-retest analysis, and internal consistency was established by Cronbach's alpha coefficient. Construct validity was evaluated using the principal factor analysis and Akaike information criterion network. Criterion validity was evaluated by comparing the MSTS scoring system with the TESS and SF-36. Test-retest analysis showed a high intraclass correlation coefficient (0.92; 95% CI, 0.88-0.95), indicating high reliability of the Japanese version of the MSTS scoring system, although a considerable ceiling effect was observed, with 23 patients (23%) given the maximum score. Cronbach's alpha coefficient was 0.87 (95% CI, 0.82-0.90), suggesting a high level of internal consistency. Factor analysis revealed that all items had high loading values and communalities; we identified a central role for the items "walking" and "gait" according to the Akaike information criterion network. The total MSTS score was correlated with that of the TESS (r = 0.81; 95% CI, 0.73-0.87; p < 0.001) and the physical component summary and physical functioning of the SF-36. The Japanese-language translation of the MSTS scoring system for the lower extremity has sufficient reliability and reasonable validity. Nevertheless, the observation of a ceiling effect suggests poor ability of this system to discriminate from among patients who have a high level of function.

  2. Reliability and accuracy of a goniometer mobile device application for video measurement of the functional movement screen deep squat test.

    PubMed

    Krause, David A; Boyd, Michael S; Hager, Allison N; Smoyer, Eric C; Thompson, Anthony T; Hollman, John H

    2015-02-01

    The squat is a fundamental movement of many athletic and daily activities. Methods to clinically assess the squat maneuver range from simple observation to the use of sophisticated equipment. The purpose of this study was to examine the reliability of Coach's Eye (TechSmith Corp), a 2-dimensional (2D) motion analysis mobile device application (app), for assessing maximal sagittal plane hip, knee, and ankle motion during a functional movement screen deep squat, and to compare range of motion values generated by it to those from a Vicon (Vicon Motion Systems Ltd) 3-dimensional (3D) motion analysis system. Twenty-six healthy subjects performed three functional movement screen deep squats recorded simultaneously by both the app (on an iPad [Apple Inc]) and the 3D motion analysis system. Joint angle data were calculated with Vicon Nexus software (Vicon Motion Systems Ltd). The app video was analyzed frame by frame to determine, and freeze on the screen, the deepest position of the squat. With a capacitive stylus reference lines were then drawn on the iPad screen to determine joint angles. Procedures were repeated with approximately 48 hours between sessions. Test-retest intrarater reliability (ICC3,1) for the app at the hip, knee, and ankle was 0.98, 0.98, and 0.79, respectively. Minimum detectable change was hip 6°, knee 6°, and ankle 7°. Hip joint angles measured with the 2D app exceeded measurements obtained with the 3D motion analysis system by approximately 40°. Differences at the knee and ankle were of lower magnitude, with mean differences of 5° and 3°, respectively. Bland-Altman analysis demonstrated a systematic bias in the hip range-of-motion measurement. No such bias was demonstrated at the knee or ankle. The 2D app demonstrated excellent reliability and appeared to be a responsive means to assess for clinical change, with minimum detectable change values ranging from 6° to 7°. These results also suggest that the 2D app may be used as an alternative to a sophisticated 3D motion analysis system for assessing sagittal plane knee and ankle motion; however, it does not appear to be a comparable alternative for assessing hip motion. 3.

  3. BurnCase 3D software validation study: Burn size measurement accuracy and inter-rater reliability.

    PubMed

    Parvizi, Daryousch; Giretzlehner, Michael; Wurzer, Paul; Klein, Limor Dinur; Shoham, Yaron; Bohanon, Fredrick J; Haller, Herbert L; Tuca, Alexandru; Branski, Ludwik K; Lumenta, David B; Herndon, David N; Kamolz, Lars-P

    2016-03-01

    The aim of this study was to compare the accuracy of burn size estimation using the computer-assisted software BurnCase 3D (RISC Software GmbH, Hagenberg, Austria) with that using a 2D scan, considered to be the actual burn size. Thirty artificial burn areas were pre planned and prepared on three mannequins (one child, one female, and one male). Five trained physicians (raters) were asked to assess the size of all wound areas using BurnCase 3D software. The results were then compared with the real wound areas, as determined by 2D planimetry imaging. To examine inter-rater reliability, we performed an intraclass correlation analysis with a 95% confidence interval. The mean wound area estimations of the five raters using BurnCase 3D were in total 20.7±0.9% for the child, 27.2±1.5% for the female and 16.5±0.1% for the male mannequin. Our analysis showed relative overestimations of 0.4%, 2.8% and 1.5% for the child, female and male mannequins respectively, compared to the 2D scan. The intraclass correlation between the single raters for mean percentage of the artificial burn areas was 98.6%. There was also a high intraclass correlation between the single raters and the 2D Scan visible. BurnCase 3D is a valid and reliable tool for the determination of total body surface area burned in standard models. Further clinical studies including different pediatric and overweight adult mannequins are warranted. Copyright © 2016 Elsevier Ltd and ISBI. All rights reserved.

  4. Development of a Computer-Based Format for the Alcohol, Smoking, and Substance Involvement Screening Test (ASSIST) With University Students.

    PubMed

    Christoff, Adriana Oliveira; Barreto, Heloisa Gomm Arruda; Boerngen-Lacerda, Roseli

    2016-07-28

    The Alcohol, Smoking, and Substance Involvement Screening Test (ASSIST) is a reliable and valid tool for the early detection of harmful and hazardous drug use in primary care settings when administered by interview in the general population. In university students, substance use is high, so a reliable and feasible screening instrument is needed. To compare the computer-based ASSIST (ASSISTc) with the interview format (ASSISTi). A convenience sample with counterbalanced design was used alternating between the ASSISTi and ASSISTc with 15-day interval. Although this is not a traditional test-retest reliability study, the same statistical analysis was used: intraclass correlations (ICC), kappa (κ), and Cronbach's alpha (α) to compare the two formats. A satisfaction questionnaire was applied immediately after the second session. Both formats were completed by the students (n = 809) over 15 days. The scores of involvement with all substances and with tobacco, alcohol, cannabis, and cocaine obtained with the two formats demonstrated excellent ICC (> .77). The level of agreement was considered substantial for tobacco (κ = .69) and cannabis (κ = .70) and moderate for alcohol (κ = .58). The consistency of the ASSISTc was considered satisfactory (α: .85 for tobacco, .73 for alcohol, and .87 for cannabis). The analysis of satisfaction and feasibility showed that the ASSISTi was easier to understand, but the two formats were considered similar when considering acceptability, ease of responding, and degree of intimidation. The two formats are acceptable, the scores are comparable, and they can be used interchangeably.

  5. An empirical comparison of a dynamic software testability metric to static cyclomatic complexity

    NASA Technical Reports Server (NTRS)

    Voas, Jeffrey M.; Miller, Keith W.; Payne, Jeffrey E.

    1993-01-01

    This paper compares the dynamic testability prediction technique termed 'sensitivity analysis' to the static testability technique termed cyclomatic complexity. The application that we chose in this empirical study is a CASE generated version of a B-737 autoland system. For the B-737 system we analyzed, we isolated those functions that we predict are more prone to hide errors during system/reliability testing. We also analyzed the code with several other well-known static metrics. This paper compares and contrasts the results of sensitivity analysis to the results of the static metrics.

  6. A simple video-based timing system for on-ice team testing in ice hockey: a technical report.

    PubMed

    Larson, David P; Noonan, Benjamin C

    2014-09-01

    The purpose of this study was to describe and evaluate a newly developed on-ice timing system for team evaluation in the sport of ice hockey. We hypothesized that this new, simple, inexpensive, timing system would prove to be highly accurate and reliable. Six adult subjects (age 30.4 ± 6.2 years) performed on ice tests of acceleration and conditioning. The performance times of the subjects were recorded using a handheld stopwatch, photocell, and high-speed (240 frames per second) video. These results were then compared to allow for accuracy calculations of the stopwatch and video as compared with filtered photocell timing that was used as the "gold standard." Accuracy was evaluated using maximal differences, typical error/coefficient of variation (CV), and intraclass correlation coefficients (ICCs) between the timing methods. The reliability of the video method was evaluated using the same variables in a test-retest analysis both within and between evaluators. The video timing method proved to be both highly accurate (ICC: 0.96-0.99 and CV: 0.1-0.6% as compared with the photocell method) and reliable (ICC and CV within and between evaluators: 0.99 and 0.08%, respectively). This video-based timing method provides a very rapid means of collecting a high volume of very accurate and reliable on-ice measures of skating speed and conditioning, and can easily be adapted to other testing surfaces and parameters.

  7. A Novel Method to Evaluate the Community Built Environment Using Photographs – Environmental Profile of a Community Health (EPOCH) Photo Neighbourhood Evaluation Tool

    PubMed Central

    Chow, Clara K.; Corsi, Daniel J.; Lock, Karen; Madhavan, Manisha; Mackie, Pam; Li, Wei; Yi, Sun; Wang, Yang; Swaminathan, Sumathi; Lopez-Jaramillo, Patricio; Gomez-Arbelaez, Diego; Avezum, Álvaro; Lear, Scott A.; Dagenais, Gilles; Teo, Koon; McKee, Martin; Yusuf, Salim

    2014-01-01

    Background Previous research has shown that environments with features that encourage walking are associated with increased physical activity. Existing methods to assess the built environment using geographical information systems (GIS) data, direct audit or large surveys of the residents face constraints, such as data availability and comparability, when used to study communities in countries in diverse parts of the world. The aim of this study was to develop a method to evaluate features of the built environment of communities using a standard set of photos. In this report we describe the method of photo collection, photo analysis instrument development and inter-rater reliability of the instrument. Methods/Principal Findings A minimum of 5 photos were taken per community in 86 communities in 5 countries according to a standard set of instructions from a designated central point of each community by researchers at each site. A standard pro forma derived from reviewing existing instruments to assess the built environment was developed and used to score the characteristics of each community. Photo sets from each community were assessed independently by three observers in the central research office according to the pro forma and the inter-rater reliability was compared by intra-class correlation (ICC). Overall 87% (53 of 60) items had an ICC of ≥0.70, 7% (4 of 60) had an ICC between 0.60 and 0.70 and 5% (3 of 60) items had an ICC ≤0.50. Conclusions/Significance Analysis of photos using a standardized protocol as described in this study offers a means to obtain reliable and reproducible information on the built environment in communities in very diverse locations around the world. The collection of the photographic data required minimal training and the analysis demonstrated high reliability for the majority of items of interest. PMID:25369366

  8. Psychometric Evaluation of the PROMIS Fatigue-Short Form Across Diverse Populations

    PubMed Central

    Ameringer, Suzanne; Elswick, R. K.; Menzies, Victoria; Robins, Jo Lynne; Starkweather, Angela; Walter, Jeanne; Gentry, Amanda Elswick; Jallo, Nancy

    2016-01-01

    Background The need for reliable, valid tools to measure patient-reported outcomes (PROs) is critical for both research and for evaluating treatment effects in practice. The Patient Reported Outcome Measurement Information System (PROMIS) Fatigue-Short Form v1.0 –Fatigue 7a (PROMIS F-SF) has had limited psychometric evaluation in various populations. Objectives The aim of the study is to examine psychometric properties of PROMIS F-SF item responses across various populations. Methods Data from five studies with common data elements were used in this secondary analysis. Samples from patients with fibromyalgia, sickle cell disease, cardiometabolic risk, pregnancy, and healthy controls were used. Reliability was estimated using Cronbach’s alpha. Dimensionality was evaluated with confirmatory factor analysis. Concurrent validity was evaluated by examining Pearson’s correlations between scores from the PROMIS F-SF, the Multidimensional Fatigue Symptom Inventory-Short Form (MFSI-SF), and the Brief Fatigue Inventory (BFI). Discriminant validity was evaluated by examining Pearson’s correlations between scores on the PROMIS F-SF and measures of stress and depressive symptoms. Known groups validity was assessed by comparing PROMIS F-SH scores in the clinical samples to healthy controls. Results Reliability of PROMIS F-SF scores was adequate across samples, ranging from .72 in the pregnancy sample to .88 in healthy controls. Unidimensionality was supported in each sample. Concurrent validity was strong; across the groups, correlations with scores on the MFSI-SF and BFI ranged from .60–.85. Correlations of the PROMIS-SF with measures of stress and depressive mood were moderate to strong, ranging from .37–.64. PROMIS F-SF scores were significantly higher in clinical samples, compared to healthy controls. Discussion Reliability and validity of the PROMIS F-SF were acceptable. The PROMIS F-SF is a suitable measure of fatigue across the four diverse clinical populations included in the analysis. PMID:27362514

  9. Eye Movement Analysis and Cognitive Assessment. The Use of Comparative Visual Search Tasks in a Non-immersive VR Application.

    PubMed

    Rosa, Pedro J; Gamito, Pedro; Oliveira, Jorge; Morais, Diogo; Pavlovic, Matthew; Smyth, Olivia; Maia, Inês; Gomes, Tiago

    2017-03-23

    An adequate behavioral response depends on attentional and mnesic processes. When these basic cognitive functions are impaired, the use of non-immersive Virtual Reality Applications (VRAs) can be a reliable technique for assessing the level of impairment. However, most non-immersive VRAs use indirect measures to make inferences about visual attention and mnesic processes (e.g., time to task completion, error rate). To examine whether the eye movement analysis through eye tracking (ET) can be a reliable method to probe more effectively where and how attention is deployed and how it is linked with visual working memory during comparative visual search tasks (CVSTs) in non-immersive VRAs. The eye movements of 50 healthy participants were continuously recorded while CVSTs, selected from a set of cognitive tasks in the Systemic Lisbon Battery (SLB). Then a VRA designed to assess of cognitive impairments were randomly presented. The total fixation duration, the number of visits in the areas of interest and in the interstimulus space, along with the total execution time was significantly different as a function of the Mini Mental State Examination (MMSE) scores. The present study demonstrates that CVSTs in SLB, when combined with ET, can be a reliable and unobtrusive method for assessing cognitive abilities in healthy individuals, opening it to potential use in clinical samples.

  10. Reliability and validity of soft copy images based on flat-panel detector in pneumoconiosis classification: comparison with the analog radiographs.

    PubMed

    Lee, Won-Jeong; Choi, Byung-Soon

    2013-06-01

    The aim of this study was to evaluate the reliability and validity of soft copy images based on flat-panel detector of digital radiography (DR-FPD soft copy images) compared to analog radiographs (ARs) in pneumoconiosis classification and diagnosis. DR-FPD soft copy images and ARs from 349 subjects were independently read by four-experienced readers according to the International Labor Organization 2000 guidelines. DR-FPD soft copy images were used to obtain consensus reading (CR) by all readers as the gold standard. Reliability and validity were evaluated by a κ and receiver operating characteristic analysis, respectively. In small opacity, overall interreader agreement of DR-FPD soft copy images was significantly higher than that of ARs, but it was not significantly different in large opacity and costophrenic angle obliteration. In small opacity, agreement of DR-FPD soft copy images with CR was significantly higher than that of ARs with CR. It was also higher than that of ARs with CR in pleural plaque and thickening. Receiver operating characteristic areas were not different significantly between DR-FPD soft copy images and ARs. DR-FPD soft copy images showed accurate and reliable results in pneumoconiosis classification and diagnosis compared to ARs. Copyright © 2013 AUR. Published by Elsevier Inc. All rights reserved.

  11. What makes an accurate and reliable subject-specific finite element model? A case study of an elephant femur

    PubMed Central

    Panagiotopoulou, O.; Wilshin, S. D.; Rayfield, E. J.; Shefelbine, S. J.; Hutchinson, J. R.

    2012-01-01

    Finite element modelling is well entrenched in comparative vertebrate biomechanics as a tool to assess the mechanical design of skeletal structures and to better comprehend the complex interaction of their form–function relationships. But what makes a reliable subject-specific finite element model? To approach this question, we here present a set of convergence and sensitivity analyses and a validation study as an example, for finite element analysis (FEA) in general, of ways to ensure a reliable model. We detail how choices of element size, type and material properties in FEA influence the results of simulations. We also present an empirical model for estimating heterogeneous material properties throughout an elephant femur (but of broad applicability to FEA). We then use an ex vivo experimental validation test of a cadaveric femur to check our FEA results and find that the heterogeneous model matches the experimental results extremely well, and far better than the homogeneous model. We emphasize how considering heterogeneous material properties in FEA may be critical, so this should become standard practice in comparative FEA studies along with convergence analyses, consideration of element size, type and experimental validation. These steps may be required to obtain accurate models and derive reliable conclusions from them. PMID:21752810

  12. Teamwork in the operating room: frontline perspectives among hospitals and operating room personnel.

    PubMed

    Sexton, J Bryan; Makary, Martin A; Tersigni, Anthony R; Pryor, David; Hendrich, Ann; Thomas, Eric J; Holzmueller, Christine G; Knight, Andrew P; Wu, Yun; Pronovost, Peter J

    2006-11-01

    The Joint Commission on Accreditation of Healthcare Organizations is proposing that hospitals measure culture beginning in 2007. However, a reliable and widely used measurement tool for the operating room (OR) setting does not currently exist. OR personnel in 60 US hospitals were surveyed using the Safety Attitudes Questionnaire. The teamwork climate domain of the survey uses six items about difficulty speaking up, conflict resolution, physician-nurse collaboration, feeling supported by others, asking questions, and heeding nurse input. To justify grouping individual-level responses to a single score at each hospital OR level, the authors used a multilevel confirmatory factor analysis, intraclass correlations, within-group interrater reliability, and Cronbach's alpha. To detect differences at the hospital OR level and by caregiver type, the authors used multivariate analysis of variance (items) and analysis of variance (scale). The response rate was 77.1%. There was robust evidence for grouping individual-level respondents to the hospital OR level using the diverse set of statistical tests, e.g., Comparative Fit Index = 0.99, root mean squared error of approximation = 0.05, and acceptable intraclasss correlations, within-group interrater reliability values, and Cronbach's alpha = 0.79. Teamwork climate differed significantly by hospital (F59, 1,911 = 4.06, P < 0.001) and OR caregiver type (F4, 1,911 = 9.96, P < 0.001). Rigorous assessment of teamwork climate is possible using this psychometrically sound teamwork climate scale. This tool and initial benchmarks allow others to compare their teamwork climate to national means, in an effort to focus more on what excellent surgical teams do well.

  13. Automated Quantitative Analysis of Retinal Microvasculature in Normal Eyes on Optical Coherence Tomography Angiography.

    PubMed

    Lupidi, Marco; Coscas, Florence; Cagini, Carlo; Fiore, Tito; Spaccini, Elisa; Fruttini, Daniela; Coscas, Gabriel

    2016-09-01

    To describe a new automated quantitative technique for displaying and analyzing macular vascular perfusion using optical coherence tomography angiography (OCT-A) and to determine a normative data set, which might be used as reference in identifying progressive changes due to different retinal vascular diseases. Reliability study. A retrospective review of 47 eyes of 47 consecutive healthy subjects imaged with a spectral-domain OCT-A device was performed in a single institution. Full-spectrum amplitude-decorrelation angiography generated OCT angiograms of the retinal superficial and deep capillary plexuses. A fully automated custom-built software was used to provide quantitative data on the foveal avascular zone (FAZ) features and the total vascular and avascular surfaces. A comparative analysis between central macular thickness (and volume) and FAZ metrics was performed. Repeatability and reproducibility were also assessed in order to establish the feasibility and reliability of the method. The comparative analysis between the superficial capillary plexus and the deep capillary plexus revealed a statistically significant difference (P < .05) in terms of FAZ perimeter, surface, and major axis and a not statistically significant difference (P > .05) when considering total vascular and avascular surfaces. A linear correlation was demonstrated between central macular thickness (and volume) and the FAZ surface. Coefficients of repeatability and reproducibility were less than 0.4, thus demonstrating high intraobserver repeatability and interobserver reproducibility for all the examined data. A quantitative approach on retinal vascular perfusion, which is visible on Spectralis OCT angiography, may offer an objective and reliable method for monitoring disease progression in several retinal vascular diseases. Copyright © 2016 Elsevier Inc. All rights reserved.

  14. Reliability and Validity of 3 Methods of Assessing Orthopedic Resident Skill in Shoulder Surgery.

    PubMed

    Bernard, Johnathan A; Dattilo, Jonathan R; Srikumaran, Uma; Zikria, Bashir A; Jain, Amit; LaPorte, Dawn M

    Traditional measures for evaluating resident surgical technical skills (e.g., case logs) assess operative volume but not level of surgical proficiency. Our goal was to compare the reliability and validity of 3 tools for measuring surgical skill among orthopedic residents when performing 3 open surgical approaches to the shoulder. A total of 23 residents at different stages of their surgical training were tested for technical skill pertaining to 3 shoulder surgical approaches using the following measures: Objective Structured Assessment of Technical Skills (OSATS) checklists, the Global Rating Scale (GRS), and a final pass/fail assessment determined by 3 upper extremity surgeons. Adverse events were recorded. The Cronbach α coefficient was used to assess reliability of the OSATS checklists and GRS scores. Interrater reliability was calculated with intraclass correlation coefficients. Correlations among OSATS checklist scores, GRS scores, and pass/fail assessment were calculated with Spearman ρ. Validity of OSATS checklists was determined using analysis of variance with postgraduate year (PGY) as a between-subjects factor. Significance was set at p < 0.05 for all tests. Criterion validity was shown between the OSATS checklists and GRS for the 3 open shoulder approaches. Checklist scores showed superior interrater reliability compared with GRS and subjective pass/fail measurements. GRS scores were positively correlated across training years. The incidence of adverse events was significantly higher among PGY-1 and PGY-2 residents compared with more experienced residents. OSATS checklists are a valid and reliable assessment of technical skills across 3 surgical shoulder approaches. However, checklist scores do not measure quality of technique. Documenting adverse events is necessary to assess quality of technique and ultimate pass/fail status. Multiple methods of assessing surgical skill should be considered when evaluating orthopedic resident surgical performance. Copyright © 2016 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.

  15. Influence of maternal body mass index on accuracy and reliability of external fetal monitoring techniques.

    PubMed

    Cohen, Wayne R; Hayes-Gill, Barrie

    2014-06-01

    To evaluate the performance of external electronic fetal heart rate and uterine contraction monitoring according to maternal body mass index. Secondary analysis of prospective equivalence study. Three US urban teaching hospitals. Seventy-four parturients with a normal term pregnancy. The parent study assessed performance of two methods of external fetal heart rate monitoring (abdominal fetal electrocardiogram and Doppler ultrasound) and of uterine contraction monitoring (electrohystero-graphy and tocodynamometry) compared with internal monitoring with fetal scalp electrode and intrauterine pressure transducer. Reliability of external techniques was assessed by the success rate and positive percent agreement with internal methods. Bland-Altman analysis determined accuracy. We analyzed data from that study according to maternal body mass index. We assessed the relationship between body mass index and monitor performance with linear regression, using body mass index as the independent variable and measures of reliability and accuracy as dependent variables. There was no significant association between maternal body mass index and any measure of reliability or accuracy for abdominal fetal electrocardiogram. By contrast, the overall positive percent agreement for Doppler ultrasound declined (p = 0.042), and the root mean square error from the Bland-Altman analysis increased in the first stage (p = 0.029) with increasing body mass index. Uterine contraction recordings from electrohysterography and tocodynamometry showed no significant deterioration related to maternal body mass index. Accuracy and reliability of fetal heart rate monitoring using abdominal fetal electrocardiogram was unaffected by maternal obesity, whereas performance of ultrasound degraded directly with maternal size. Both electrohysterography and tocodynamometry were unperturbed by obesity. © 2014 Nordic Federation of Societies of Obstetrics and Gynecology.

  16. Reliability and validity of Edinburgh visual gait score as an evaluation tool for children with cerebral palsy.

    PubMed

    Del Pilar Duque Orozco, Maria; Abousamra, Oussama; Church, Chris; Lennon, Nancy; Henley, John; Rogers, Kenneth J; Sees, Julieanne P; Connor, Justin; Miller, Freeman

    2016-09-01

    Assessment of gait abnormalities in cerebral palsy (CP) is challenging, and access to instrumented gait analysis is not always feasible. Therefore, many observational gait analysis scales have been devised. This study aimed to evaluate the interobserver reliability, intraobserver reliability, and validity of Edinburgh visual gait score (EVGS). Video of 30 children with spastic CP were reviewed by 7 raters (10 children each in GMFCS levels I, II, and III, age 6-12 years). Three observers had high level of experience in gait analysis (10+ years), two had medium level (2-5 years) and two had no previous experience (orthopedic fellows). Interobserver reliability was evaluated using percentage of complete agreement and kappa values. Criterion validity was evaluated by comparing EVGS scores with 3DGA data taken from the same video visit. Interobserver agreement was 60-90% and Kappa values were 0.18-0.85 for the 17 items in EVGS. Reliability was higher for distal segments (foot/ankle/knee 63-90%; trunk/pelvis/hip 60-76%), with greater experience (high 66-91%, medium 62-90%, no-experience 41-87%), with more EVGS practice (1st 10 videos 52-88%, last 10 videos 64-97%) and when used with higher functioning children (GMFCS I 65-96%, II 58-90%, III 35-65%). Intraobserver agreement was 64-92%. Agreement between EVGS and 3DGA was 52-73%. We believe that having EVGS as part of the standardized gait evaluation is helpful in optimizing the visual scoring. EVGS can be a supportive tool that adds quantitative data instead of only qualitative assessment to a video only gait evaluation. Copyright © 2016 Elsevier B.V. All rights reserved.

  17. Integrating Reliability Analysis with a Performance Tool

    NASA Technical Reports Server (NTRS)

    Nicol, David M.; Palumbo, Daniel L.; Ulrey, Michael

    1995-01-01

    A large number of commercial simulation tools support performance oriented studies of complex computer and communication systems. Reliability of these systems, when desired, must be obtained by remodeling the system in a different tool. This has obvious drawbacks: (1) substantial extra effort is required to create the reliability model; (2) through modeling error the reliability model may not reflect precisely the same system as the performance model; (3) as the performance model evolves one must continuously reevaluate the validity of assumptions made in that model. In this paper we describe an approach, and a tool that implements this approach, for integrating a reliability analysis engine into a production quality simulation based performance modeling tool, and for modeling within such an integrated tool. The integrated tool allows one to use the same modeling formalisms to conduct both performance and reliability studies. We describe how the reliability analysis engine is integrated into the performance tool, describe the extensions made to the performance tool to support the reliability analysis, and consider the tool's performance.

  18. A tonic heat test stimulus yields a larger and more reliable conditioned pain modulation effect compared to a phasic heat test stimulus

    PubMed Central

    Lie, Marie Udnesseter; Matre, Dagfinn; Hansson, Per; Stubhaug, Audun; Zwart, John-Anker; Nilsen, Kristian Bernhard

    2017-01-01

    Abstract Introduction: The interest in conditioned pain modulation (CPM) as a clinical tool for measuring endogenously induced analgesia is increasing. There is, however, large variation in the CPM methodology, hindering comparison of results across studies. Research comparing different CPM protocols is needed in order to obtain a standardized test paradigm. Objectives: The aim of the study was to assess whether a protocol with phasic heat stimuli as test-stimulus is preferable to a protocol with tonic heat stimulus as test-stimulus. Methods: In this experimental crossover study, we compared 2 CPM protocols with different test-stimulus; one with tonic test-stimulus (constant heat stimulus of 120-second duration) and one with phasic test-stimuli (3 heat stimulations of 5 seconds duration separated by 10 seconds). Conditioning stimulus was a 7°C water bath in parallel with the test-stimulus. Twenty-four healthy volunteers were assessed on 2 occasions with minimum 1 week apart. Differences in the magnitude and test–retest reliability of the CPM effect in the 2 protocols were investigated with repeated-measures analysis of variance and by relative and absolute reliability indices. Results: The protocol with tonic test-stimulus induced a significantly larger CPM effect compared to the protocol with phasic test-stimuli (P < 0.001). Fair and good relative reliability was found with the phasic and tonic test-stimuli, respectively. Absolute reliability indices showed large intraindividual variability from session to session in both protocols. Conclusion: The present study shows that a CPM protocol with a tonic test-stimulus is preferable to a protocol with phasic test-stimuli. However, we emphasize that one should be cautious to use the CPM effect as biomarker or in clinical decision making on an individual level due to large intraindividual variability. PMID:29392240

  19. Warranty optimisation based on the prediction of costs to the manufacturer using neural network model and Monte Carlo simulation

    NASA Astrophysics Data System (ADS)

    Stamenkovic, Dragan D.; Popovic, Vladimir M.

    2015-02-01

    Warranty is a powerful marketing tool, but it always involves additional costs to the manufacturer. In order to reduce these costs and make use of warranty's marketing potential, the manufacturer needs to master the techniques for warranty cost prediction according to the reliability characteristics of the product. In this paper a combination free replacement and pro rata warranty policy is analysed as warranty model for one type of light bulbs. Since operating conditions have a great impact on product reliability, they need to be considered in such analysis. A neural network model is used to predict light bulb reliability characteristics based on the data from the tests of light bulbs in various operating conditions. Compared with a linear regression model used in the literature for similar tasks, the neural network model proved to be a more accurate method for such prediction. Reliability parameters obtained in this way are later used in Monte Carlo simulation for the prediction of times to failure needed for warranty cost calculation. The results of the analysis make possible for the manufacturer to choose the optimal warranty policy based on expected product operating conditions. In such a way, the manufacturer can lower the costs and increase the profit.

  20. Non-stationarity in US droughts and implications for water resources planning and management

    NASA Astrophysics Data System (ADS)

    Apurv, T.; Cai, X.

    2017-12-01

    The concepts of return period and reliability are widely used in hydrology for quantifying the risk of extreme events. The conventional way of calculating return period and reliability requires the assumption of stationarity and independence of extreme events in successive years. These assumptions may not be true for droughts since a single drought event can last for more than one year. Further, droughts are known to be influenced by multi-year to multi-decadal oscillations (eg. El Nino Southern Oscillation (ENSO), Atlantic Multidecadal Oscillation (AMO), Pacific Decadal Oscillation (PDO)), which means that the underlying distribution can change with time. In this study, we develop a non-stationary frequency analysis for relating meteorological droughts in the continental US (CONUS) with physical covariates. We calculate the return period and reliability of meteorological droughts in different parts of CONUS by considering the correlation and the non-stationarity in drought events. We then compare the return period and reliability calculated assuming non-stationarity with that calculated assuming stationarity. The difference between the two estimates is used to quantify the extent of non-stationarity in droughts in different parts of CONUS. We also use the non-stationary frequency analysis model for attributing the causes of non-stationarity. Finally we will discuss the implications for water resources planning and management in the United States.

  1. Validity and Reliability of the Brazilian Version of the Rapid Estimate of Adult Literacy in Dentistry--BREALD-30.

    PubMed

    Junkes, Monica C; Fraiz, Fabian C; Sardenberg, Fernanda; Lee, Jessica Y; Paiva, Saul M; Ferreira, Fernanda M

    2015-01-01

    The aim of the present study was to translate, perform the cross-cultural adaptation of the Rapid Estimate of Adult Literacy in Dentistry to Brazilian-Portuguese language and test the reliability and validity of this version. After translation and cross-cultural adaptation, interviews were conducted with 258 parents/caregivers of children in treatment at the pediatric dentistry clinics and health units in Curitiba, Brazil. To test the instrument's validity, the scores of Brazilian Rapid Estimate of Adult Literacy in Dentistry (BREALD-30) were compared based on occupation, monthly household income, educational attainment, general literacy, use of dental services and three dental outcomes. The BREALD-30 demonstrated good internal reliability. Cronbach's alpha ranged from 0.88 to 0.89 when words were deleted individually. The analysis of test-retest reliability revealed excellent reproducibility (intraclass correlation coefficient = 0.983 and Kappa coefficient ranging from moderate to nearly perfect). In the bivariate analysis, BREALD-30 scores were significantly correlated with the level of general literacy (rs = 0.593) and income (rs = 0.327) and significantly associated with occupation, educational attainment, use of dental services, self-rated oral health and the respondent's perception regarding his/her child's oral health. However, only the association between the BREALD-30 score and the respondent's perception regarding his/her child's oral health remained significant in the multivariate analysis. The BREALD-30 demonstrated satisfactory psychometric properties and is therefore applicable to adults in Brazil.

  2. Validity and Reliability of the Brazilian Version of the Rapid Estimate of Adult Literacy in Dentistry – BREALD-30

    PubMed Central

    Junkes, Monica C.; Fraiz, Fabian C.; Sardenberg, Fernanda; Lee, Jessica Y.; Paiva, Saul M.; Ferreira, Fernanda M.

    2015-01-01

    Objective The aim of the present study was to translate, perform the cross-cultural adaptation of the Rapid Estimate of Adult Literacy in Dentistry to Brazilian-Portuguese language and test the reliability and validity of this version. Methods After translation and cross-cultural adaptation, interviews were conducted with 258 parents/caregivers of children in treatment at the pediatric dentistry clinics and health units in Curitiba, Brazil. To test the instrument's validity, the scores of Brazilian Rapid Estimate of Adult Literacy in Dentistry (BREALD-30) were compared based on occupation, monthly household income, educational attainment, general literacy, use of dental services and three dental outcomes. Results The BREALD-30 demonstrated good internal reliability. Cronbach’s alpha ranged from 0.88 to 0.89 when words were deleted individually. The analysis of test-retest reliability revealed excellent reproducibility (intraclass correlation coefficient = 0.983 and Kappa coefficient ranging from moderate to nearly perfect). In the bivariate analysis, BREALD-30 scores were significantly correlated with the level of general literacy (rs = 0.593) and income (rs = 0.327) and significantly associated with occupation, educational attainment, use of dental services, self-rated oral health and the respondent’s perception regarding his/her child's oral health. However, only the association between the BREALD-30 score and the respondent’s perception regarding his/her child's oral health remained significant in the multivariate analysis. Conclusion The BREALD-30 demonstrated satisfactory psychometric properties and is therefore applicable to adults in Brazil. PMID:26158724

  3. Reconciling Streamflow Uncertainty Estimation and River Bed Morphology Dynamics. Insights from a Probabilistic Assessment of Streamflow Uncertainties Using a Reliability Diagram

    NASA Astrophysics Data System (ADS)

    Morlot, T.; Mathevet, T.; Perret, C.; Favre Pugin, A. C.

    2014-12-01

    Streamflow uncertainty estimation has recently received a large attention in the literature. A dynamic rating curve assessment method has been introduced (Morlot et al., 2014). This dynamic method allows to compute a rating curve for each gauging and a continuous streamflow time-series, while calculating streamflow uncertainties. Streamflow uncertainty takes into account many sources of uncertainty (water level, rating curve interpolation and extrapolation, gauging aging, etc.) and produces an estimated distribution of streamflow for each days. In order to caracterise streamflow uncertainty, a probabilistic framework has been applied on a large sample of hydrometric stations of the Division Technique Générale (DTG) of Électricité de France (EDF) hydrometric network (>250 stations) in France. A reliability diagram (Wilks, 1995) has been constructed for some stations, based on the streamflow distribution estimated for a given day and compared to a real streamflow observation estimated via a gauging. To build a reliability diagram, we computed the probability of an observed streamflow (gauging), given the streamflow distribution. Then, the reliability diagram allows to check that the distribution of probabilities of non-exceedance of the gaugings follows a uniform law (i.e., quantiles should be equipropables). Given the shape of the reliability diagram, the probabilistic calibration is caracterised (underdispersion, overdispersion, bias) (Thyer et al., 2009). In this paper, we present case studies where reliability diagrams have different statistical properties for different periods. Compared to our knowledge of river bed morphology dynamic of these hydrometric stations, we show how reliability diagram gives us invaluable information on river bed movements, like a continuous digging or backfilling of the hydraulic control due to erosion or sedimentation processes. Hence, the careful analysis of reliability diagrams allows to reconcile statistics and long-term river bed morphology processes. This knowledge improves our real-time management of hydrometric stations, given a better caracterisation of erosion/sedimentation processes and the stability of hydrometric station hydraulic control.

  4. Preliminary Analysis of LORAN-C System Reliability for Civil Aviation.

    DTIC Science & Technology

    1981-09-01

    overviev of the analysis technique. Section 3 describes the computerized LORAN-C coverage model which is used extensively in the reliability analysis...Xth Plenary Assembly, Geneva, 1963, published by International Telecomunications Union. S. Braff, R., Computer program to calculate a Karkov Chain Reliability Model, unpublished york, MITRE Corporation. A-1 I.° , 44J Ili *Y 0E 00 ...F i8 1110 Prelim inary Analysis of Program Engineering & LORAN’C System ReliabilityMaintenance Service i ~Washington. D.C.

  5. Approximate Evaluation of Reliability and Availability via Perturbation Analysis.

    DTIC Science & Technology

    1986-12-01

    generating the dxact answers to which the results of the approximation will be compared are discussed:." - 87 7" 2 04 2LOISTRIGUTIONIAVAILASILITYI OF...appropriately, constructing the Markov process that approximately governs interclass behavior from the result above (this is called the enlarged... compared to a numerical or analytical computation of the aame quantities. This work and its continuation represents our progress so far on Goal 3. 2.4I

  6. Validity and reliability of an instrumented leg-extension machine for measuring isometric muscle strength of the knee extensors.

    PubMed

    Ruschel, Caroline; Haupenthal, Alessandro; Jacomel, Gabriel Fernandes; Fontana, Heiliane de Brito; Santos, Daniela Pacheco dos; Scoz, Robson Dias; Roesler, Helio

    2015-05-20

    Isometric muscle strength of knee extensors has been assessed for estimating performance, evaluating progress during physical training, and investigating the relationship between isometric and dynamic/functional performance. To assess the validity and reliability of an adapted leg-extension machine for measuring isometric knee extensor force. Validity (concurrent approach) and reliability (test and test-retest approach) study. University laboratory. 70 healthy men and women aged between 20 and 30 y (39 in the validity study and 31 in the reliability study). Intraclass correlation coefficient (ICC) values calculated for the maximum voluntary isometric torque of knee extensors at 30°, 60°, and 90°, measured with the prototype and with an isokinetic dynamometer (ICC2,1, validity study) and measured with the prototype in test and retest sessions, scheduled from 48 h to 72 h apart (ICC1,1, reliability study). In the validity analysis, the prototype showed good agreement for measurements at 30° (ICC2,1 = .75, SEM = 18.2 Nm) and excellent agreement for measurements at 60° (ICC2,1 = .93, SEM = 9.6 Nm) and at 90° (ICC2,1 = .94, SEM = 8.9 Nm). Regarding the reliability analysis, between-days' ICC1,1 were good to excellent, ranging from .88 to .93. Standard error of measurement and minimal detectable difference based on test-retest ranged from 11.7 Nm to 18.1 Nm and 32.5 Nm to 50.1 Nm, respectively, for the 3 analyzed knee angles. The analysis of validity and repeatability of the prototype for measuring isometric muscle strength has shown to be good or excellent, depending on the knee joint angle analyzed. The new instrument, which presents a relative low cost and easiness of transportation when compared with an isokinetic dynamometer, is valid and provides consistent data concerning isometric strength of knee extensors and, for this reason, can be used for practical, clinical, and research purposes.

  7. Development and preliminary validation of a questionnaire to measure satisfaction with home care in Greece: an exploratory factor analysis of polychoric correlations

    PubMed Central

    2010-01-01

    Background The primary aim of this study was to develop and psychometrically test a Greek-language instrument for measuring satisfaction with home care. The first empirical evidence about the level of satisfaction with these services in Greece is also provided. Methods The questionnaire resulted from literature search, on-site observation and cognitive interviews. It was applied in 2006 to a sample of 201 enrollees of five home care programs in the city of Thessaloniki and contains 31 items that measure satisfaction with individual service attributes and are expressed on a 5-point Likert scale. The latter has been usually considered in practice as an interval scale, although it is in principle ordinal. We thus treated the variable as an ordinal one, but also employed the traditional approach in order to compare the findings. Our analysis was therefore based on ordinal measures such as the polychoric correlation, Kendall's Tau b coefficient and ordinal Cronbach's alpha. Exploratory factor analysis was followed by an assessment of internal consistency reliability, test-retest reliability, construct validity and sensitivity. Results Analyses with ordinal and interval scale measures produced in essence very similar results and identified four multi-item scales. Three of these were found to be reliable and valid: socioeconomic change, staff skills and attitudes and service appropriateness. A fourth dimension -service planning- had lower internal consistency reliability and yet very satisfactory test-retest reliability, construct validity and floor and ceiling effects. The global satisfaction scale created was also quite reliable. Overall, participants were satisfied -yet not very satisfied- with home care services. More room for improvement seems to exist for the socio-economic and planning aspects of care and less for staff skills and attitudes and appropriateness of provided services. Conclusions The methods developed seem to be a promising tool for the measurement of home care satisfaction in Greece. PMID:20602759

  8. The Dula Dangerous Driving Index: An Investigation of Reliability and Validity across Cultures

    PubMed Central

    Willemsen, Jochem; Dula, Chris S.; Declercq, Frédéric; Verhaeghe, Paul

    2008-01-01

    The aim of this study is to further establish the validity and reliability of the Dula Dangerous Driving Index (DDDI). The reliability and validity of the instrument was investigated by comparing data from a US university sample, a US community sample, and a sample of Belgian traffic offenders. Exploratory and confirmatory factor analysis supported the presence of a four-factor structure with items for Drunk Driving forming a separate scale apart from items for Risky Driving, Negative Cognitive/Emotional Driving and Aggressive Driving. A multi-group confirmatory factor analysis with model constraints supported the validity of the DDDI. Inter-correlations revealed that the DDDI subscales are closely interrelated and uni-dimensionality of the measure was found in all three samples. This suggests the DDDI Total score can be used as a composite measure for dangerous driving. However, the validity of the subscales was demonstrated in the Belgian sample, as specific traffic offender groups (convicted for drunk driving, aggressive driving, speeding) scored higher on corresponding scales (Drunk Driving, Aggressive Driving, and Risky Driving, respectively), indicating that it is clinically meaningful to differentiate the subscales. PMID:18329435

  9. A symptom self-rating scale for schizophrenia (4S): psychometric properties, reliability and validity.

    PubMed

    Lindström, Eva; Jedenius, Erik; Levander, Sten

    2009-01-01

    The objective of the study was to validate a self-administrated symptom rating scale for use in patients with schizophrenia spectrum disorders by item analysis, exploration of factor structure, and analyses of reliability and validity. Data on 151 patients, initially treated by risperidone, obtained within the framework of a naturalistic Phase IV longitudinal study, were analysed by comparing patient and clinician ratings of symptoms, side-effects and global indices of illness. The Symptom Self-rating Scale for Schizophrenia (4S) is psychometrically adequate (item analysis, internal consistency, factor structure). Side-effect ratings were reliable. Symptom ratings displayed consistent associations with clinicians' ratings of corresponding symptom dimensions, suggesting construct validity. Patients had most difficulties assessing negative symptom items. Patients were well able to assess their own symptoms and drug side-effects. The factor structure of symptom ratings differs between patients and clinicians as well as how they construe global indices of illness. Clinicians focus on psychotic, patients on affective symptoms. Use of symptom self-ratings is one way to improve communication and thereby strengthen the therapeutic alliance and increase treatment adherence.

  10. Optimal Bi-Objective Redundancy Allocation for Systems Reliability and Risk Management.

    PubMed

    Govindan, Kannan; Jafarian, Ahmad; Azbari, Mostafa E; Choi, Tsan-Ming

    2016-08-01

    In the big data era, systems reliability is critical to effective systems risk management. In this paper, a novel multiobjective approach, with hybridization of a known algorithm called NSGA-II and an adaptive population-based simulated annealing (APBSA) method is developed to solve the systems reliability optimization problems. In the first step, to create a good algorithm, we use a coevolutionary strategy. Since the proposed algorithm is very sensitive to parameter values, the response surface method is employed to estimate the appropriate parameters of the algorithm. Moreover, to examine the performance of our proposed approach, several test problems are generated, and the proposed hybrid algorithm and other commonly known approaches (i.e., MOGA, NRGA, and NSGA-II) are compared with respect to four performance measures: 1) mean ideal distance; 2) diversification metric; 3) percentage of domination; and 4) data envelopment analysis. The computational studies have shown that the proposed algorithm is an effective approach for systems reliability and risk management.

  11. Computational methods for efficient structural reliability and reliability sensitivity analysis

    NASA Technical Reports Server (NTRS)

    Wu, Y.-T.

    1993-01-01

    This paper presents recent developments in efficient structural reliability analysis methods. The paper proposes an efficient, adaptive importance sampling (AIS) method that can be used to compute reliability and reliability sensitivities. The AIS approach uses a sampling density that is proportional to the joint PDF of the random variables. Starting from an initial approximate failure domain, sampling proceeds adaptively and incrementally with the goal of reaching a sampling domain that is slightly greater than the failure domain to minimize over-sampling in the safe region. Several reliability sensitivity coefficients are proposed that can be computed directly and easily from the above AIS-based failure points. These probability sensitivities can be used for identifying key random variables and for adjusting design to achieve reliability-based objectives. The proposed AIS methodology is demonstrated using a turbine blade reliability analysis problem.

  12. Development and Validation of a Portable and Inexpensive Tool to Measure the Drop Vertical Jump Using the Microsoft Kinect V2.

    PubMed

    Gray, Aaron D; Willis, Brad W; Skubic, Marjorie; Huo, Zhiyu; Razu, Swithin; Sherman, Seth L; Guess, Trent M; Jahandar, Amirhossein; Gulbrandsen, Trevor R; Miller, Scott; Siesener, Nathan J

    Noncontact anterior cruciate ligament (ACL) injury in adolescent female athletes is an increasing problem. The knee-ankle separation ratio (KASR), calculated at initial contact (IC) and peak flexion (PF) during the drop vertical jump (DVJ), is a measure of dynamic knee valgus. The Microsoft Kinect V2 has shown promise as a reliable and valid marker-less motion capture device. The Kinect V2 will demonstrate good to excellent correlation between KASR results at IC and PF during the DVJ, as compared with a "gold standard" Vicon motion analysis system. Descriptive laboratory study. Level 2. Thirty-eight healthy volunteer subjects (20 male, 18 female) performed 5 DVJ trials, simultaneously measured by a Vicon MX-T40S system, 2 AMTI force platforms, and a Kinect V2 with customized software. A total of 190 jumps were completed. The KASR was calculated at IC and PF during the DVJ. The intraclass correlation coefficient (ICC) assessed the degree of KASR agreement between the Kinect and Vicon systems. The ICCs of the Kinect V2 and Vicon KASR at IC and PF were 0.84 and 0.95, respectively, showing excellent agreement between the 2 measures. The Kinect V2 successfully identified the KASR at PF and IC frames in 182 of 190 trials, demonstrating 95.8% reliability. The Kinect V2 demonstrated excellent ICC of the KASR at IC and PF during the DVJ when compared with the Vicon system. A customized Kinect V2 software program demonstrated good reliability in identifying the KASR at IC and PF during the DVJ. Reliable, valid, inexpensive, and efficient screening tools may improve the accessibility of motion analysis assessment of adolescent female athletes.

  13. Behavioral and cognitive outcomes for clinical trials in children with neurofibromatosis type 1.

    PubMed

    van der Vaart, Thijs; Rietman, André B; Plasschaert, Ellen; Legius, Eric; Elgersma, Ype; Moll, Henriëtte A

    2016-01-12

    To evaluate the appropriateness of cognitive and behavioral outcome measures in clinical trials in neurofibromatosis type 1 (NF1) by analyzing the degree of deficits compared to reference groups, test-retest reliability, and how scores correlate between outcome measures. Data were analyzed from the Simvastatin for cognitive deficits and behavioral problems in patients with neurofibromatosis type 1 (NF1-SIMCODA) trial, a randomized placebo-controlled trial of simvastatin for cognitive deficits and behavioral problems in children with NF1. Outcome measures were compared with age-specific reference groups to identify domains of dysfunction. Pearson r was computed for before and after measurements within the placebo group to assess test-retest reliability. Principal component analysis was used to identify the internal structure in the outcome data. Strongest mean score deviations from the reference groups were observed for full-scale intelligence (-1.1 SD), Rey Complex Figure Test delayed recall (-2.0 SD), attention problems (-1.2 SD), and social problems (-1.1 SD). Long-term test-retest reliability were excellent for Wechsler scales (r > 0.88), but poor to moderate for other neuropsychological tests (r range 0.52-0.81) and Child Behavioral Checklist subscales (r range 0.40-0.79). The correlation structure revealed 2 strong components in the outcome measures behavior and cognition, with no correlation between these components. Scores on psychosocial quality of life correlate strongly with behavioral problems and less with cognitive deficits. Children with NF1 show distinct deficits in multiple domains. Many outcome measures showed weak test-retest correlations over the 1-year trial period. Cognitive and behavioral outcomes are complementary. This analysis demonstrates the need to include reliable outcome measures on a variety of cognitive and behavioral domains in clinical trials for NF1. © 2015 American Academy of Neurology.

  14. A Meta-Analysis of Hemodynamic Studies on First and Second Language Processing: Which Suggested Differences Can We Trust and What Do They Mean?

    ERIC Educational Resources Information Center

    Indefrey, Peter

    2006-01-01

    This article presents the results of a meta-analysis of 30 hemodynamic experiments comparing first language (L1) and second language (L2) processing in a range of tasks. The results suggest that reliably stronger activation during L2 processing is found (a) only for task-specific subgroups of L2 speakers and (b) within some, but not all regions…

  15. Periods of High Intensity Solar Proton Flux

    NASA Technical Reports Server (NTRS)

    Xapsos, Michael A.; Stauffer, Craig A.; Jordan, Thomas M.; Adams, James H.; Dietrich, William F.

    2012-01-01

    Analysis is presented for times during a space mission that specified solar proton flux levels are exceeded. This includes both total time and continuous time periods during missions. Results for the solar maximum and solar minimum phases of the solar cycle are presented and compared for a broad range of proton energies and shielding levels. This type of approach is more amenable to reliability analysis for spacecraft systems and instrumentation than standard statistical models.

  16. Optimization Testbed Cometboards Extended into Stochastic Domain

    NASA Technical Reports Server (NTRS)

    Patnaik, Surya N.; Pai, Shantaram S.; Coroneos, Rula M.; Patnaik, Surya N.

    2010-01-01

    COMparative Evaluation Testbed of Optimization and Analysis Routines for the Design of Structures (CometBoards) is a multidisciplinary design optimization software. It was originally developed for deterministic calculation. It has now been extended into the stochastic domain for structural design problems. For deterministic problems, CometBoards is introduced through its subproblem solution strategy as well as the approximation concept in optimization. In the stochastic domain, a design is formulated as a function of the risk or reliability. Optimum solution including the weight of a structure, is also obtained as a function of reliability. Weight versus reliability traced out an inverted-S-shaped graph. The center of the graph corresponded to 50 percent probability of success, or one failure in two samples. A heavy design with weight approaching infinity could be produced for a near-zero rate of failure that corresponded to unity for reliability. Weight can be reduced to a small value for the most failure-prone design with a compromised reliability approaching zero. The stochastic design optimization (SDO) capability for an industrial problem was obtained by combining three codes: MSC/Nastran code was the deterministic analysis tool, fast probabilistic integrator, or the FPI module of the NESSUS software, was the probabilistic calculator, and CometBoards became the optimizer. The SDO capability requires a finite element structural model, a material model, a load model, and a design model. The stochastic optimization concept is illustrated considering an academic example and a real-life airframe component made of metallic and composite materials.

  17. An analysis of functional shoulder movements during task performance using Dartfish movement analysis software.

    PubMed

    Khadilkar, Leenesh; MacDermid, Joy C; Sinden, Kathryn E; Jenkyn, Thomas R; Birmingham, Trevor B; Athwal, George S

    2014-01-01

    Video-based movement analysis software (Dartfish) has potential for clinical applications for understanding shoulder motion if functional measures can be reliably obtained. The primary purpose of this study was to describe the functional range of motion (ROM) of the shoulder used to perform a subset of functional tasks. A second purpose was to assess the reliability of functional ROM measurements obtained by different raters using Dartfish software. Ten healthy participants, mean age 29 ± 5 years, were videotaped while performing five tasks selected from the Disabilities of the Arm, Shoulder and Hand (DASH). Video cameras and markers were used to obtain video images suitable for analysis in Dartfish software. Three repetitions of each task were performed. Shoulder movements from all three repetitions were analyzed using Dartfish software. The tracking tool of the Dartfish software was used to obtain shoulder joint angles and arcs of motion. Test-retest and inter-rater reliability of the measurements were evaluated using intraclass correlation coefficients (ICC). Maximum (coronal plane) abduction (118° ± 16°) and (sagittal plane) flexion (111° ± 15°) was observed during 'washing one's hair;' maximum extension (-68° ± 9°) was identified during 'washing one's own back.' Minimum shoulder ROM was observed during 'opening a tight jar' (33° ± 13° abduction and 13° ± 19° flexion). Test-retest reliability (ICC = 0.45 to 0.94) suggests high inter-individual task variability, and inter-rater reliability (ICC = 0.68 to 1.00) showed moderate to excellent agreement. KEY FINDINGS INCLUDE: 1) functional shoulder ROM identified in this study compared to similar studies; 2) healthy individuals require less than full ROM when performing five common ADL tasks 3) high participant variability was observed during performance of the five ADL tasks; and 4) Dartfish software provides a clinically relevant tool to analyze shoulder function.

  18. Meta-Analysis of Scale Reliability Using Latent Variable Modeling

    ERIC Educational Resources Information Center

    Raykov, Tenko; Marcoulides, George A.

    2013-01-01

    A latent variable modeling approach is outlined that can be used for meta-analysis of reliability coefficients of multicomponent measuring instruments. Important limitations of efforts to combine composite reliability findings across multiple studies are initially pointed out. A reliability synthesis procedure is discussed that is based on…

  19. The Impact Analysis of Psychological Reliability of Population Pilot Study for Selection of Particular Reliable Multi-Choice Item Test in Foreign Language Research Work

    ERIC Educational Resources Information Center

    Fazeli, Seyed Hossein

    2010-01-01

    The purpose of research described in the current study is the psychological reliability, its importance, application, and more to investigate on the impact analysis of psychological reliability of population pilot study for selection of particular reliable multi-choice item test in foreign language research work. The population for subject…

  20. [Surgical technique in patients with chronic pancreatitis].

    PubMed

    Pronin, N A; Natalskiy, A A; Tarasenko, S V; Pavlov, A V; Fedoseev, V A

    To justify ligation of vascular branches of anterior pancreateroduodenal arterial arch or gastroduodenal artery prior to bifurcation. This method was tested on sufficient clinical material: 147 patients with recurrent chronic pancreatitis. The interventions are presented by Frey, Beger procedures and its Berne variant. Comparative analysis showed reliable advantages of vascular ligation during pancreatectomy.

  1. CREATING A DECISION CONTEXT FOR COMPARATIVE ANALYSIS AND CONSISTENT APPLICATION OF INHALATION DOSIMETRY MODELS IN CHILDREN'S RISK ASSESSMENT

    EPA Science Inventory

    Estimation of risks to children from exposure to airborne pollutants is often complicated by the lack of reliable epidemiological data specific to this age group. As a result, risks are generally estimated from extrapolations based on data obtained in other human age groups (e.g....

  2. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kim, Hang Bae

    A reliability testing was performed for the software of Shutdown(SDS) Computers for Wolsong Nuclear Power Plants Units 2, 3 and 4. profiles to the SDS Computers and compared the outputs with the predicted results generated by the oracle. Test softwares were written to execute the test automatically. Random test profiles were generated using analysis code. 11 refs., 1 fig.

  3. Starting Strong 2017: Key OECD Indicators on Early Childhood Education and Care

    ERIC Educational Resources Information Center

    OECD Publishing, 2017

    2017-01-01

    Early childhood education and care (ECEC) can help lay the foundations for future skills development, well-being and learning. Having timely, reliable and comparable international information is essential to help countries improve their ECEC services and systems. For over 15 years, the OECD has been conducting policy analysis and gathering new…

  4. The Almanac of American Education, 2013. Seventh Edition. U.S. DataBook Series

    ERIC Educational Resources Information Center

    Gaquin, Deirdre A., Ed.; Dunn, Gwenavere W., Ed.

    2013-01-01

    The "Almanac of American Education" helps users understand and compare the quality of education at the national, state, and county levels. Compiled from official U.S. government and reliable private sources, the book contains historical and current data, insightful analysis, and useful graphs that provide compelling insights into the…

  5. The Almanac of American Education, 2014-2015. Eighth Edition. U.S. DataBook Series

    ERIC Educational Resources Information Center

    Gaquin, Deirdre A., Ed.; Dunn, Gwenavere W., Ed.

    2015-01-01

    The "Almanac of American Education" helps users understand and compare the quality of education at the national, state, and county levels. Compiled from official U.S. government and reliable private sources, the book contains historical and current data, insightful analysis, and useful graphs that provide compelling insights into the…

  6. A multicenter study of viable PCR using propidium monoazide to detect Legionella in water samples.

    PubMed

    Scaturro, Maria; Fontana, Stefano; Dell'eva, Italo; Helfer, Fabrizia; Marchio, Michele; Stefanetti, Maria Vittoria; Cavallaro, Mario; Miglietta, Marilena; Montagna, Maria Teresa; De Giglio, Osvalda; Cuna, Teresa; Chetti, Leonarda; Sabattini, Maria Antonietta Bucci; Carlotti, Michela; Viggiani, Mariagabriella; Stenico, Alberta; Romanin, Elisa; Bonanni, Emma; Ottaviano, Claudio; Franzin, Laura; Avanzini, Claudio; Demarie, Valerio; Corbella, Marta; Cambieri, Patrizia; Marone, Piero; Rota, Maria Cristina; Bella, Antonino; Ricci, Maria Luisa

    2016-07-01

    Legionella quantification in environmental samples is overestimated by qPCR. Combination with a viable dye, such as Propidium monoazide (PMA), could make qPCR (named then vPCR) very reliable. In this multicentre study 717 artificial water samples, spiked with fixed concentrations of Legionella and interfering bacterial flora, were analysed by qPCR, vPCR and culture and data were compared by statistical analysis. A heat-treatment at 55 °C for 10 minutes was also performed to obtain viable and not-viable bacteria. When data of vPCR were compared with those of culture and qPCR, statistical analysis showed significant differences (P < 0.001). However, although the heat-treatment caused an abatement of CFU/mL ≤1 to 1 log10 unit, the comparison between untreated and heat-treated samples analysed by vPCR highlighted non-significant differences (P > 0.05). Overall this study provided a good experimental reproducibility of vPCR but also highlighted limits of PMA in the discriminating capability of dead and live bacteria, making vPCR not completely reliable. Copyright © 2016 Elsevier Inc. All rights reserved.

  7. An innovative and comprehensive technique to evaluate different measures of medication adherence: The network meta-analysis.

    PubMed

    Tonin, Fernanda S; Wiecek, Elyssa; Torres-Robles, Andrea; Pontarolo, Roberto; Benrimoj, Shalom Charlie I; Fernandez-Llimos, Fernando; Garcia-Cardenas, Victoria

    2018-05-19

    Poor medication adherence is associated with adverse health outcomes and higher costs of care. However, inconsistencies in the assessment of adherence are found in the literature. To evaluate the effect of different measures of adherence in the comparative effectiveness of complex interventions to enhance patients' adherence to prescribed medications. A systematic review with network meta-analysis was performed. Electronic searches for relevant pairwise meta-analysis including trials of interventions that aimed to improve medication adherence were performed in PubMed. Data extraction was conducted with eligible trials evaluating short-period adherence follow-up (until 3 months) using any measure of adherence: self-report, pill count, or MEMS (medication event monitoring system). To standardize the results obtained with these different measures, an overall composite measure and an objective composite measure were also calculated. Network meta-analyses for each measure of adherence were built. Rank order and surface under the cumulative ranking curve analyses (SUCRA) were performed. Ninety-one trials were included in the network meta-analyses. The five network meta-analyses demonstrated robustness and reliability. Results obtained for all measures of adherence were similar across them and to both composite measures. For both composite measures, interventions comprising economic + technical components were the best option (90% of probability in SUCRA analysis) with statistical superiority against almost all other interventions and against standard care (odds ratio with 95% credibility interval ranging from 0.09 to 0.25 [0.02, 0.98]). The use of network meta-analysis was reliable to compare different measures of adherence of complex interventions in short-periods follow-up. Analyses with longer follow-up periods are needed to confirm these results. Different measures of adherence produced similar results. The use of composite measures revealed reliable alternatives to establish a broader and more detailed picture of adherence. Copyright © 2018 Elsevier Inc. All rights reserved.

  8. Semi-Markov adjunction to the Computer-Aided Markov Evaluator (CAME)

    NASA Technical Reports Server (NTRS)

    Rosch, Gene; Hutchins, Monica A.; Leong, Frank J.; Babcock, Philip S., IV

    1988-01-01

    The rule-based Computer-Aided Markov Evaluator (CAME) program was expanded in its ability to incorporate the effect of fault-handling processes into the construction of a reliability model. The fault-handling processes are modeled as semi-Markov events and CAME constructs and appropriate semi-Markov model. To solve the model, the program outputs it in a form which can be directly solved with the Semi-Markov Unreliability Range Evaluator (SURE) program. As a means of evaluating the alterations made to the CAME program, the program is used to model the reliability of portions of the Integrated Airframe/Propulsion Control System Architecture (IAPSA 2) reference configuration. The reliability predictions are compared with a previous analysis. The results bear out the feasibility of utilizing CAME to generate appropriate semi-Markov models to model fault-handling processes.

  9. Reliability and Validity of the Physical Education Activities Scale.

    PubMed

    Thomason, Diane L; Feng, Du

    2016-06-01

    Measuring adolescent perceptions of physical education (PE) activities is necessary in understanding determinants of school PE activity participation. This study assessed reliability and validity of the Physical Education Activities Scale (PEAS), a 41-item visual analog scale measuring high school adolescent perceptions of school PE activity participation. Adolescents (N = 529) from the Pacific Northwest aged 15-19 in grades 9-12 participated in the study. Construct validity was assessed using exploratory factor analysis (EFA) and confirmatory factor analysis (CFA). Measurement invariance across sex groups was tested by multiple-group CFA. Internal consistency reliability was analyzed using Cronbach's alpha. Inter-subscale correlations (Pearson's r) were calculated for latent factors and observed subscale scores. Exploratory factor analysis suggested a 3-factor solution explaining 43.4% of the total variance. Confirmatory factor analysis showed the 3-factor model fit the data adequately (comparative fit index [CFI] = 0.90, Tucker-Lewis index [TLI] = 0.89, root mean squared error of approximation [RMSEA] = 0.063). Factorial invariance was supported. Cronbach's alpha of the total PEAS was α = 0.92, and for subscales α ranged from 0.65 to 0.92. Independent t-tests showed significantly higher mean scores for boys than girls on the total scale and all subscales. Findings provide psychometric support for using the PEAS for examining adolescent's psychosocial and environmental perceptions to participating in PE activities. © 2016, American School Health Association.

  10. Radiologic analysis of hindfoot alignment: Comparison of Méary, long axial, and hindfoot alignment views.

    PubMed

    Neri, T; Barthelemy, R; Tourné, Y

    2017-12-01

    Among radiographic views available for assessing hindfoot alignment, the antero-posterior weight-bearing view with metal cerclage of the hindfoot (Méary view) is the most widely used in France. Internationally, the long axial view (LAV) and hindfoot alignment view (HAV) are used also. The objective of this study was to compare the reliability of these three views. The Méary view with cerclage of the hindfoot is as reliable as the LAV and HAV for assessing hindfoot alignment. All three views were obtained in each of 22 prospectively included patients. Intra-observer and inter-observer reliabilities were assessed by having two observers collect the radiographic measurements then computing the intra-class correlation coefficients (ICCs). The intra-observer and inter-observer ICCs were 0.956 and 0.988 with the Méary view, 0.990 and 0.765 with the HAV, and 0.997 and 0.991 with the LAV, respectively. Correlations were far stronger between the LAV and HAV than between each of these and the Méary view. Compared to the LAV and HAV, the Méary view indicated a greater degree of hindfoot valgus. Intra-observer reliability was excellent with both the LAV and HAV, whereas inter-observer reliability was better with the LAV. Excellent reliability was also obtained with the Méary view. Combining the Méary view to obtain a radiographic image of the clinical deformity with the LAV to measure the angular deviation of the hindfoot axis may be useful when assessing hindfoot malalignment. A comparison of the three views in a larger population is needed before clinical recommendations can be made. II, prospective study. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  11. Wearable Lactate Threshold Predicting Device is Valid and Reliable in Runners.

    PubMed

    Borges, Nattai R; Driller, Matthew W

    2016-08-01

    Borges, NR and Driller, MW. Wearable lactate threshold predicting device is valid and reliable in runners. J Strength Cond Res 30(8): 2212-2218, 2016-A commercially available device claiming to be the world's first wearable lactate threshold predicting device (WLT), using near-infrared LED technology, has entered the market. The aim of this study was to determine the levels of agreement between the WLT-derived lactate threshold workload and traditional methods of lactate threshold (LT) calculation and the interdevice and intradevice reliability of the WLT. Fourteen (7 male, 7 female; mean ± SD; age: 18-45 years, height: 169 ± 9 cm, mass: 67 ± 13 kg, V[Combining Dot Above]O2max: 53 ± 9 ml·kg·min) subjects ranging from recreationally active to highly trained athletes completed an incremental exercise test to exhaustion on a treadmill. Blood lactate samples were taken at the end of each 3-minute stage during the test to determine lactate threshold using 5 traditional methods from blood lactate analysis which were then compared against the WLT predicted value. In a subset of the population (n = 12), repeat trials were performed to determine both inter-reliability and intrareliability of the WLT device. Intraclass correlation coefficient (ICC) found high to very high agreement between the WLT and traditional methods (ICC > 0.80), with TEMs and mean differences ranging between 3.9-10.2% and 1.3-9.4%. Both interdevice and intradevice reliability resulted in highly reproducible and comparable results (CV < 1.2%, TEM <0.2 km·h, ICC > 0.97). This study suggests that the WLT is a practical, reliable, and noninvasive tool for use in predicting LT in runners.

  12. Delirium diagnosis defined by cluster analysis of symptoms versus diagnosis by DSM and ICD criteria: diagnostic accuracy study.

    PubMed

    Sepulveda, Esteban; Franco, José G; Trzepacz, Paula T; Gaviria, Ana M; Meagher, David J; Palma, José; Viñuelas, Eva; Grau, Imma; Vilella, Elisabet; de Pablo, Joan

    2016-05-26

    Information on validity and reliability of delirium criteria is necessary for clinicians, researchers, and further developments of DSM or ICD. We compare four DSM and ICD delirium diagnostic criteria versions, which were developed by consensus of experts, with a phenomenology-based natural diagnosis delineated using cluster analysis of delirium features in a sample with a high prevalence of dementia. We also measured inter-rater reliability of each system when applied by two evaluators from distinct disciplines. Cross-sectional analysis of 200 consecutive patients admitted to a skilled nursing facility, independently assessed within 24-48 h after admission with the Delirium Rating Scale-Revised-98 (DRS-R98) and for DSM-III-R, DSM-IV, DSM-5, and ICD-10 criteria for delirium. Cluster analysis (CA) delineated natural delirium and nondelirium reference groups using DRS-R98 items and then diagnostic systems' performance were evaluated against the CA-defined groups using logistic regression and crosstabs for discriminant analysis (sensitivity, specificity, percentage of subjects correctly classified by each diagnostic system and their individual criteria, and performance for each system when excluding each individual criterion are reported). Kappa Index (K) was used to report inter-rater reliability for delirium diagnostic systems and their individual criteria. 117 (58.5 %) patients had preexisting dementia according to the Informant Questionnaire on Cognitive Decline in the Elderly. CA delineated 49 delirium subjects and 151 nondelirium. Against these CA groups, delirium diagnosis accuracy was highest using DSM-III-R (87.5 %) followed closely by DSM-IV (86.0 %), ICD-10 (85.5 %) and DSM-5 (84.5 %). ICD-10 had the highest specificity (96.0 %) but lowest sensitivity (53.1 %). DSM-III-R had the best sensitivity (81.6 %) and the best sensitivity-specificity balance. DSM-5 had the highest inter-rater reliability (K =0.73) while DSM-III-R criteria were the least reliable. Using our CA-defined, phenomenologically-based delirium designations as the reference standard, we found performance discordance among four diagnostic systems when tested in subjects where comorbid dementia was prevalent. The most complex diagnostic systems have higher accuracy and the newer DSM-5 have higher reliability. Our novel phenomenological approach to designing a delirium reference standard may be preferred to guide revisions of diagnostic systems in the future.

  13. Cross-Cultural Adaptation and Validation of the Voice Handicap Index into Thai.

    PubMed

    Jaruchinda, Pariyanan; Suwanwarangkool, Thadchai

    2015-12-01

    The voice handicap index (VHI) is one of the most utilized instruments for measuring a patient's self-assessment of voice severity. The VHI has been translated into several languages, but not in Thai. To examine the psychometric properties of a Thai translation of the voice Handicap Index (VHI) and assess the applicability in the screening diagnosis. After receiving permission from the American Speech Language Hearing Association (ASHA), the original VHI had been translated and adapted to Thai by forward and backward standard translation. Eighty-five patients with voice disorders, divided in four groups according to the etiology of the diseases (neurogenic, structural, functional, and inflammatory), and 30 asymptomatic subjects were included in the present study. Internal consistency was analyzed through Cronbach's a coefficient. For the VHI test-retest reliability analysis, the Thai VHI was completed twice by 22 patients and assessed through the intraclass correlation coefficient. For clinical validity evaluation, the VHI scores from the pathological group were compared with the control group and compared among the four different pathological groups. The cutoff point for distinguishing the normal from the patient group was assessed by ROC analysis. Effects of age and gender on VHI scores were also evaluated. The Thai VHI showed a significant high internal consistency and test-retest reliability (Cronbach's α = 0.96 and r = 0.843, respectively). Mann-Whitney U test was used to compare the control group and pathological groups and revealed significant difference in total scores and its three domains scores (p < 0.001). ROC analysis demonstrated that a VHI score of 13 should be considered the threshold for revealing the impact of quality of life in voice disorder patients. Age and gender were not affect the VHI scores in both control and patient groups. The Thai VHI has high reliability and validity. The Thai version of VHI is considered to be a self-assessment tool for the severity of voice disorders in Thai patients.

  14. Structural Reliability Using Probability Density Estimation Methods Within NESSUS

    NASA Technical Reports Server (NTRS)

    Chamis, Chrisos C. (Technical Monitor); Godines, Cody Ric

    2003-01-01

    A reliability analysis studies a mathematical model of a physical system taking into account uncertainties of design variables and common results are estimations of a response density, which also implies estimations of its parameters. Some common density parameters include the mean value, the standard deviation, and specific percentile(s) of the response, which are measures of central tendency, variation, and probability regions, respectively. Reliability analyses are important since the results can lead to different designs by calculating the probability of observing safe responses in each of the proposed designs. All of this is done at the expense of added computational time as compared to a single deterministic analysis which will result in one value of the response out of many that make up the density of the response. Sampling methods, such as monte carlo (MC) and latin hypercube sampling (LHS), can be used to perform reliability analyses and can compute nonlinear response density parameters even if the response is dependent on many random variables. Hence, both methods are very robust; however, they are computationally expensive to use in the estimation of the response density parameters. Both methods are 2 of 13 stochastic methods that are contained within the Numerical Evaluation of Stochastic Structures Under Stress (NESSUS) program. NESSUS is a probabilistic finite element analysis (FEA) program that was developed through funding from NASA Glenn Research Center (GRC). It has the additional capability of being linked to other analysis programs; therefore, probabilistic fluid dynamics, fracture mechanics, and heat transfer are only a few of what is possible with this software. The LHS method is the newest addition to the stochastic methods within NESSUS. Part of this work was to enhance NESSUS with the LHS method. The new LHS module is complete, has been successfully integrated with NESSUS, and been used to study four different test cases that have been proposed by the Society of Automotive Engineers (SAE). The test cases compare different probabilistic methods within NESSUS because it is important that a user can have confidence that estimates of stochastic parameters of a response will be within an acceptable error limit. For each response, the mean, standard deviation, and 0.99 percentile, are repeatedly estimated which allows confidence statements to be made for each parameter estimated, and for each method. Thus, the ability of several stochastic methods to efficiently and accurately estimate density parameters is compared using four valid test cases. While all of the reliability methods used performed quite well, for the new LHS module within NESSUS it was found that it had a lower estimation error than MC when they were used to estimate the mean, standard deviation, and 0.99 percentile of the four different stochastic responses. Also, LHS required a smaller amount of calculations to obtain low error answers with a high amount of confidence than MC. It can therefore be stated that NESSUS is an important reliability tool that has a variety of sound probabilistic methods a user can employ and the newest LHS module is a valuable new enhancement of the program.

  15. Bridge reliability assessment based on the PDF of long-term monitored extreme strains

    NASA Astrophysics Data System (ADS)

    Jiao, Meiju; Sun, Limin

    2011-04-01

    Structural health monitoring (SHM) systems can provide valuable information for the evaluation of bridge performance. As the development and implementation of SHM technology in recent years, the data mining and use has received increasingly attention and interests in civil engineering. Based on the principle of probabilistic and statistics, a reliability approach provides a rational basis for analysis of the randomness in loads and their effects on structures. A novel approach combined SHM systems with reliability method to evaluate the reliability of a cable-stayed bridge instrumented with SHM systems was presented in this paper. In this study, the reliability of the steel girder of the cable-stayed bridge was denoted by failure probability directly instead of reliability index as commonly used. Under the assumption that the probability distributions of the resistance are independent to the responses of structures, a formulation of failure probability was deduced. Then, as a main factor in the formulation, the probability density function (PDF) of the strain at sensor locations based on the monitoring data was evaluated and verified. That Donghai Bridge was taken as an example for the application of the proposed approach followed. In the case study, 4 years' monitoring data since the operation of the SHM systems was processed, and the reliability assessment results were discussed. Finally, the sensitivity and accuracy of the novel approach compared with FORM was discussed.

  16. A study of low-cost reliable actuators for light aircraft. Part A: Chapters 1-8

    NASA Technical Reports Server (NTRS)

    Eijsink, H.; Rice, M.

    1978-01-01

    An analysis involving electro-mechanical, electro-pneumatic, and electro-hydraulic actuators was performed to study which are compatible for use in the primary and secondary flight controls of a single engine light aircraft. Actuator characteristics under investigation include cost, reliability, weight, force, volumetric requirements, power requirements, response characteristics and heat accumulation characteristics. The basic types of actuators were compared for performance characteristics in positioning a control surface model and then were mathematically evaluated in an aircraft to get the closed loop dynamic response characteristics. Conclusions were made as to the suitability of each actuator type for use in an aircraft.

  17. Comparison of reliability and responsiveness of patient-reported clinical outcome measures in knee osteoarthritis rehabilitation.

    PubMed

    Williams, Valerie J; Piva, Sara R; Irrgang, James J; Crossley, Chad; Fitzgerald, G Kelley

    2012-08-01

    Secondary analysis, pretreatment-posttreatment observational study. To compare the reliability and responsiveness of the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), the Knee Outcome Survey activities of daily living subscale (KOS-ADL), and the Lower Extremity Functional Scale (LEFS) in individuals with knee osteoarthritis (OA). The WOMAC is the current standard in patient-reported measures of function in patients with knee OA. The KOS-ADL and LEFS were designed for potential use in patients with knee OA. If the KOS-ADL and LEFS are to be considered viable alternatives to the WOMAC for measuring patient-reported function in individuals with knee OA, they should have measurement properties comparable to the WOMAC. It would also be important to determine whether either of these instruments may be superior to the WOMAC in terms of reliability or responsiveness in this population. Data from 168 subjects with knee OA, who participated in a rehabilitation program, were used in the analyses. Reliability and responsiveness of each outcome measure were estimated at follow-ups of 2, 6, and 12 months. Reliability was estimated by calculating the intraclass correlation coefficient (ICC2,1) for subjects who were unchanged in status from baseline at each follow-up time, based on a global rating of change score. To examine responsiveness, the standard error of the measurement, minimal detectable change, minimal clinically important difference, and the Guyatt responsiveness index were calculated for each outcome measure at each follow-up time. All 3 outcome measures demonstrated reasonable reliability and responsiveness to change. Reliability and responsiveness tended to decrease somewhat with increasing follow-up time. There were no substantial differences between outcome measures for reliability or any of the 3 measures of responsiveness at any follow-up time. The results do not indicate that one outcome measure is more reliable or responsive than another when applied to subjects with knee OA. We believe that all 3 instruments are appropriate outcome measures to examine change in functional status of patients with knee OA.

  18. National Launch System comparative economic analysis

    NASA Technical Reports Server (NTRS)

    Prince, A.

    1992-01-01

    Results are presented from an analysis of economic benefits (or losses), in the form of the life cycle cost savings, resulting from the development of the National Launch System (NLS) family of launch vehicles. The analysis was carried out by comparing various NLS-based architectures with the current Shuttle/Titan IV fleet. The basic methodology behind this NLS analysis was to develop a set of annual payload requirements for the Space Station Freedom and LEO, to design launch vehicle architectures around these requirements, and to perform life-cycle cost analyses on all of the architectures. A SEI requirement was included. Launch failure costs were estimated and combined with the relative reliability assumptions to measure the effects of losses. Based on the analysis, a Shuttle/NLS architecture evolving into a pressurized-logistics-carrier/NLS architecture appears to offer the best long-term cost benefit.

  19. The Reliability and Validity of Measures of Gait Variability in Community-Dwelling Older Adults

    PubMed Central

    Brach, Jennifer S.; Perera, Subashan; Studenski, Stephanie; Newman, Anne B.

    2009-01-01

    Objective To examine the test-retest reliability and concurrent validity of variability of gait characteristics. Design Cross-sectional study. Setting Research laboratory. Participants Older adults (N=558) from the Cardiovascular Health Study. Interventions Not applicable. Main Outcome Measures Gait characteristics were measured using a 4-m computerized walkway. SD determined from the steps recorded were used as the measures of variability. Intraclass correlation coefficients (ICC) were calculated to examine test-retest reliability of a 4-m walk and two 4-m walks. To establish concurrent validity, the measures of gait variability were compared across levels of health, functional status, and physical activity using independent t tests and analysis of variances. Results Gait variability measures from the two 4-m walks demonstrated greater test-retest reliability than those from the single 4-m walk (ICC=.22–.48 and ICC=.40–.63, respectively). Greater step length and stance time variability were associated with poorer health, functional status and physical activity (P<.05). Conclusions Gait variability calculated from a limited number of steps has fair to good test-retest reliability and concurrent validity. Reliability of gait variability calculated from a greater number of steps should be assessed to determine if the consistency can be improved. PMID:19061741

  20. A proposed method to investigate reliability throughout a questionnaire.

    PubMed

    Wentzel-Larsen, Tore; Norekvål, Tone M; Ulvik, Bjørg; Nygård, Ottar; Pripp, Are H

    2011-10-05

    Questionnaires are used extensively in medical and health care research and depend on validity and reliability. However, participants may differ in interest and awareness throughout long questionnaires, which can affect reliability of their answers. A method is proposed for "screening" of systematic change in random error, which could assess changed reliability of answers. A simulation study was conducted to explore whether systematic change in reliability, expressed as changed random error, could be assessed using unsupervised classification of subjects by cluster analysis (CA) and estimation of intraclass correlation coefficient (ICC). The method was also applied on a clinical dataset from 753 cardiac patients using the Jalowiec Coping Scale. The simulation study showed a relationship between the systematic change in random error throughout a questionnaire and the slope between the estimated ICC for subjects classified by CA and successive items in a questionnaire. This slope was proposed as an awareness measure--to assessing if respondents provide only a random answer or one based on a substantial cognitive effort. Scales from different factor structures of Jalowiec Coping Scale had different effect on this awareness measure. Even though assumptions in the simulation study might be limited compared to real datasets, the approach is promising for assessing systematic change in reliability throughout long questionnaires. Results from a clinical dataset indicated that the awareness measure differed between scales.

  1. Accelerated benzene polycarboxylic acid analysis by liquid chromatography-time-of-flight-mass spectrometry for the determination of petrogenic and pyrogenic carbon.

    PubMed

    Hindersmann, Benjamin; Achten, Christine

    2017-08-11

    Pyrogenic carbon species are of particular interest due to their ubiquitous occurrence in the environment and their high sorption capacities for nonpolar organic compounds. It has recently been shown that the analysis of the molecular markers for complex aromatic carbon structures, benzene polycarboxylic acids (BPCA), has a high potential for aid in the identification of different carbon sources. In this study, the first LC method using mass spectrometry (MS) for reliable and accelerated (<24h) quantification of pyrogenic and petrogenic carbon by BPCA analysis has been developed. The main advantage of LC-MS compared to previous methods is the higher sensitivity, which is important if only small sample amounts are available. Sample pre-treatment could be reduced to a minimum. Deuterated phthalic acid was introduced as internal standard due to its structural similarity to BPCA and its lack of occurrence in the environment. Linear quantification with r 2 ≥0997 was accomplished for all BPCA. Method validation showed an excellent quantification reproducibility (mean CV<5%) which is comparable to LC-DAD methods and more reliable than GC-FID measurements (CV 16-23%). In summary, the presented BPCA method is more economic, efficient and presumably attractive to use. Besides reference materials, various pyrogenic and petrogenic samples were analyzed to test if the sources were indicated by BPCA analysis. In addition to pyrogenic carbon, large amounts of petrogenic carbon species can also be present in urban soils and river sediments, especially in mining regions. They also to a large degree consist of aromatic carbon structures and therefore have an impact on source identification by BPCA analysis. Comparison of petrogenic and pyrogenic carbon samples shows similarities in the BPCA concentrations and patterns, in their aromaticity and degree of aromatic condensation. Thus, a differentiation between petrogenic and pyrogenic carbon only by BPCA analysis of samples with unknown carbon sources is not possible. For reliable source identification of the carbon species, the combination with other methods, such as e. g. analysis of polycyclic aromatic hydrocarbons may be successful. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. Comparison of manual & automated analysis methods for corneal endothelial cell density measurements by specular microscopy.

    PubMed

    Huang, Jianyan; Maram, Jyotsna; Tepelus, Tudor C; Modak, Cristina; Marion, Ken; Sadda, SriniVas R; Chopra, Vikas; Lee, Olivia L

    2017-08-07

    To determine the reliability of corneal endothelial cell density (ECD) obtained by automated specular microscopy versus that of validated manual methods and factors that predict such reliability. Sharp central images from 94 control and 106 glaucomatous eyes were captured with Konan specular microscope NSP-9900. All images were analyzed by trained graders using Konan CellChek Software, employing the fully- and semi-automated methods as well as Center Method. Images with low cell count (input cells number <100) and/or guttata were compared with the Center and Flex-Center Methods. ECDs were compared and absolute error was used to assess variation. The effect on ECD of age, cell count, cell size, and cell size variation was evaluated. No significant difference was observed between the Center and Flex-Center Methods in corneas with guttata (p=0.48) or low ECD (p=0.11). No difference (p=0.32) was observed in ECD of normal controls <40 yrs old between the fully-automated method and manual Center Method. However, in older controls and glaucomatous eyes, ECD was overestimated by the fully-automated method (p=0.034) and semi-automated method (p=0.025) as compared to manual method. Our findings show that automated analysis significantly overestimates ECD in the eyes with high polymegathism and/or large cell size, compared to the manual method. Therefore, we discourage reliance upon the fully-automated method alone to perform specular microscopy analysis, particularly if an accurate ECD value is imperative. Copyright © 2017. Published by Elsevier España, S.L.U.

  3. Investigating the Reliability and Factor Structure of Kalichman's "Survey 2: Research Misconduct" Questionnaire: A Post Hoc Analysis Among Biomedical Doctoral Students in Scandinavia.

    PubMed

    Holm, Søren; Hofmann, Bjørn

    2017-10-01

    A precondition for reducing scientific misconduct is evidence about scientists' attitudes. We need reliable survey instruments, and this study investigates the reliability of Kalichman's "Survey 2: research misconduct" questionnaire. The study is a post hoc analysis of data from three surveys among biomedical doctoral students in Scandinavia (2010-2015). We perform reliability analysis, and exploratory and confirmatory factor analysis using a split-sample design as a partial validation. The results indicate that a reliable 13-item scale can be formed (Cronbach's α = .705), and factor analysis indicates that there are four reliable subscales each tapping a different construct: (a) general attitude to misconduct (α = .768), (b) attitude to personal misconduct (α = .784), (c) attitude to whistleblowing (α = .841), and (d) attitude to blameworthiness/punishment (α = .877). A full validation of the questionnaire requires further research. We, nevertheless, hope that the results will facilitate the increased use of the questionnaire in research.

  4. Laser-induced tissue autofluorescence versus exogenous chemical probe induced fluorescence as an arterial layer detection method: a comparative study

    NASA Astrophysics Data System (ADS)

    Papazoglou, Theodore G.; Arakawa, Koh; Grundfest, Warren S.; Papaioannou, Thanassis; Fishbein, Michael C.; Litvack, Frank

    1990-07-01

    The goal ofihis sludy was o develop a reliable laser inducedfluorescence specira analysis system using the 308nm Excimer Laser as an ablaiion andfluorescence inducing source. During our analysis we also aflempled lo determine whether exogenous chloroeiracycline hydrocloride (CTC) increased the discrimination capacity of the LIFS system. We then assessed the ability of CTC to improve the detection of the boundary between atheroma and normal media.

  5. The better way to determine the validity, reliability, objectivity and accuracy of measuring devices.

    PubMed

    Pazira, Parvin; Rostami Haji-Abadi, Mahdi; Zolaktaf, Vahid; Sabahi, Mohammadfarzan; Pazira, Toomaj

    2016-06-08

    In relation to statistical analysis, studies to determine the validity, reliability, objectivity and precision of new measuring devices are usually incomplete, due in part to using only correlation coefficient and ignoring the data dispersion. The aim of this study was to demonstrate the best way to determine the validity, reliability, objectivity and accuracy of an electro-inclinometer or other measuring devices. Another purpose of this study is to answer the question of whether reliability and objectivity represent accuracy of measuring devices. The validity of an electro-inclinometer was examined by mechanical and geometric methods. The objectivity and reliability of the device was assessed by calculating Cronbach's alpha for repeated measurements by three raters and by measurements on the same person by mechanical goniometer and the electro-inclinometer. Measurements were performed on "hip flexion with the extended knee" and "shoulder abduction with the extended elbow." The raters measured every angle three times within an interval of two hours. The three-way ANOVA was used to determine accuracy. The results of mechanical and geometric analysis showed that validity of the electro-inclinometer was 1.00 and level of error was less than one degree. Objectivity and reliability of electro-inclinometer was 0.999, while objectivity of mechanical goniometer was in the range of 0.802 to 0.966 and the reliability was 0.760 to 0.961. For hip flexion, the difference between raters in joints angle measurement by electro-inclinometer and mechanical goniometer was 1.74 and 16.33 degree (P<0.05), respectively. The differences for shoulder abduction measurement by electro-inclinometer and goniometer were 0.35 and 4.40 degree (P<0.05). Although both the objectivity and reliability are acceptable, the results showed that measurement error was very high in the mechanical goniometer. Therefore, it can be concluded that objectivity and reliability alone cannot determine the accuracy of a device and it is preferable to use other statistical methods to compare and evaluate the accuracy of these two devices.

  6. Characterization of fiber diameter using image analysis

    NASA Astrophysics Data System (ADS)

    Baheti, S.; Tunak, M.

    2017-10-01

    Due to high surface area and porosity, the applications of nanofibers have increased in recent years. In the production process, determination of average fiber diameter and fiber orientation is crucial for quality assessment. The objective of present study was to compare the relative performance of different methods discussed in literature for estimation of fiber diameter. In this work, the existing automated fiber diameter analysis software packages available in literature were developed and validated based on simulated images of known fiber diameter. Finally, all methods were compared for their reliable and accurate estimation of fiber diameter in electro spun nanofiber membranes based on obtained mean and standard deviation.

  7. Structural design and analysis for an ultra low CTE optical bench for the Hubble Space Telescope corrective optics

    NASA Technical Reports Server (NTRS)

    Neam, Douglas C.; Gerber, John D.

    1992-01-01

    The stringent stability requirements of the Corrective Optics Space Telescope Axial Replacement (COSTAR) necessitates a Deployable Optical Bench (DOB) with both a low CTE and high resonant frequency. The DOB design consists of a monocoque thin shell structure which marries metallic machined parts with graphite epoxy formed structure. Structural analysis of the DOB has been integrated into the laminate design and optimization process. Also, the structural analytical results are compared with vibration and thermal test data to assess the reliability of the analysis.

  8. Facial Aesthetic Outcomes of Cleft Surgery: Assessment of Discrete Lip and Nose Images Compared with Digital Symmetry Analysis.

    PubMed

    Deall, Ciara E; Kornmann, Nirvana S S; Bella, Husam; Wallis, Katy L; Hardwicke, Joseph T; Su, Ting-Li; Richard, Bruce M

    2016-10-01

    High-quality aesthetic outcomes are of paramount importance to children growing up after cleft lip and palate surgery. Establishing a validated and reliable assessment tool for cleft professionals and families will facilitate cleft units, surgeons, techniques, and protocols to be audited and compared with greater confidence. This study used exemplar images across a five-point aesthetic scale, identified in a pilot project, to score lips and noses as separate units and compared these human scores with computer-based SymNose symmetry scores. Forty-five assessors (17 cleft surgeons nationally and 28 other cleft professionals from the UK South West Tri-centre units), scored 25 standardized photographs, uploaded randomly onto a Web-based platform, twice. Each photograph was shown in three forms: lip and nose together, and separately cropped images of nose only and lip only. The same images were analyzed using the SymNose software program. Scoring lips gave the best intrarater and interrater reliabilities. Nose scores were more variable. Lip scoring associated most closely with the whole-image score. SymNose ranking of the lip images related highly to the same ranking by humans (p = 0.001). The exemplar images maintained their established previous ranking. Images illustrating the aesthetic outcome grades are confirmed. The lip score is reliable and seems to dominate in the whole-image score. Noses are much harder to score reliably. It appears that SymNose can score lip images very effectively by symmetry. Further use of SymNose will be investigated, and families of children with cleft will trial the scoring system. Therapeutic, III.

  9. Comparison of hospital databases on antibiotic consumption in France, for a single management tool.

    PubMed

    Henard, S; Boussat, S; Demoré, B; Clément, S; Lecompte, T; May, T; Rabaud, C

    2014-07-01

    The surveillance of antibiotic use in hospitals and of data on resistance is an essential measure for antibiotic stewardship. There are 3 national systems in France to collect data on antibiotic use: DREES, ICATB, and ATB RAISIN. We compared these databases and drafted recommendations for the creation of an optimized database of information on antibiotic use, available to all concerned personnel: healthcare authorities, healthcare facilities, and healthcare professionals. We processed and analyzed the 3 databases (2008 data), and surveyed users. The qualitative analysis demonstrated major discrepancies in terms of objectives, healthcare facilities, participation rate, units of consumption, conditions for collection, consolidation, and control of data, and delay before availability of results. The quantitative analysis revealed that the consumption data for a given healthcare facility differed from one database to another, challenging the reliability of data collection. We specified user expectations: to compare consumption and resistance data, to carry out benchmarking, to obtain data on the prescribing habits in healthcare units, or to help understand results. The study results demonstrated the need for a reliable, single, and automated tool to manage data on antibiotic consumption compared with resistance data on several levels (national, regional, healthcare facility, healthcare units), providing rapid local feedback and educational benchmarking. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  10. [Quality of information analysis on basic causes of neonatal deaths recorded in the Mortality Information System: a study in Maceió, Alagoas State, Brazil, 2001-2002].

    PubMed

    Pedrosa, Linda Délia C O; Sarinho, Silvia W; Ordonha, Manoelina R

    2007-10-01

    Analysis of the quality of information on basic causes of neonatal deaths in Brazil is crucially important, since it allows one to estimate how many deaths are avoidable and provide support for policies to decrease neonatal mortality. The current study aimed to evaluate the reliability and validity of the Mortality Information System (MIS) for discriminating between basic causes of neonatal deaths and defining percentages of reducible causes. The basic causes of early neonatal deaths in hospitals in Maceió, Alagoas State, were analyzed, and the causes recorded in medical records were compared to the MIS data in order to measure reliability and validity. The modified SEADE Foundation and Wigglesworth classifications were compared to analyze the capacity for reduction of neonatal mortality. Maternal causes predominated in the medical records, as compared to respiratory disorders on the death certificates and in the MIS. The percentage of avoidable deaths may be much higher than observed from the MIS, due to imprecision in completing death certificates. Based on the MIS, the greatest problems are in early diagnosis and treatment of neonatal causes. However, the results show that the most pressing problems relate to failures in prenatal care and lack of control of diseases.

  11. Psychometric Inferences from a Meta-Analysis of Reliability and Internal Consistency Coefficients

    ERIC Educational Resources Information Center

    Botella, Juan; Suero, Manuel; Gambara, Hilda

    2010-01-01

    A meta-analysis of the reliability of the scores from a specific test, also called reliability generalization, allows the quantitative synthesis of its properties from a set of studies. It is usually assumed that part of the variation in the reliability coefficients is due to some unknown and implicit mechanism that restricts and biases the…

  12. Reliability of an Automated High-Resolution Manometry Analysis Program across Expert Users, Novice Users, and Speech-Language Pathologists

    ERIC Educational Resources Information Center

    Jones, Corinne A.; Hoffman, Matthew R.; Geng, Zhixian; Abdelhalim, Suzan M.; Jiang, Jack J.; McCulloch, Timothy M.

    2014-01-01

    Purpose: The purpose of this study was to investigate inter- and intrarater reliability among expert users, novice users, and speech-language pathologists with a semiautomated high-resolution manometry analysis program. We hypothesized that all users would have high intrarater reliability and high interrater reliability. Method: Three expert…

  13. A Reliability Generalization Study of the Marlowe-Crowne Social Desirability Scale.

    ERIC Educational Resources Information Center

    Beretvas, S, Natasha; Meyers, Jason L.; Leite, Walter L.

    2002-01-01

    Conducted a reliability generalization study of the Marlowe-Crowne Social Desirability Scale (D. Crowne and D. Marlowe, 1960). Analysis of 93 studies show that the predicted score reliability for male adolescents was 0.53, and reliability for men's responses was lower than for women's. Discusses the need for further analysis of the scale. (SLD)

  14. GAPDH, β-actin and β2-microglobulin, as three common reference genes, are not reliable for gene expression studies in equine adipose- and marrow-derived mesenchymal stem cells.

    PubMed

    Nazari, Fatemeh; Parham, Abbas; Maleki, Adham Fani

    2015-01-01

    Quantitative real time reverse transcription PCR (qRT-PCR) is one of the most important techniques for gene-expression analysis in molecular based studies. Selecting a proper internal control gene for normalizing data is a crucial step in gene expression analysis via this method. The expression levels of reference genes should be remained constant among cells in different tissues. However, it seems that the location of cells in different tissues might influence their expression. The purpose of this study was to determine whether the source of mesenchymal stem cells (MSCs) has any effect on expression level of three common reference genes (GAPDH, β-actin and β2-microglobulin) in equine marrow- and adipose- derived undifferentiated MSCs and consequently their reliability for comparative qRT-PCR. Adipose tissue (AT) and bone marrow (BM) samples were harvested from 3 mares. MSCs were isolated and cultured until passage 3 (P3). Total RNA of P3 cells was extracted for cDNA synthesis. The generated cDNAs were analyzed by quantitative real-time PCR. The PCR reactions were ended with a melting curve analysis to verify the specificity of amplicon. The expression levels of GAPDH were significantly different between AT- and BM- derived MSCs (p < 0.05). Differences in expression level of β-actin (P < 0.001) and B2M (P < 0.006.) between MSCs derived from AT and BM were substantially higher than GAPDH. In addition, the fold change in expression levels of GAPDH, β-actin and B2M in AT-derived MSCs compared to BM-derived MSCs were 2.38, 6.76 and 7.76, respectively. This study demonstrated that GAPDH and especially β-actin and B2M express in different levels in equine AT- and BM- derived MSCs. Thus they cannot be considered as reliable reference genes for comparative quantitative gene expression analysis in MSCs derived from equine bone marrow and adipose tissue.

  15. Automated digital image analysis of islet cell mass using Nikon's inverted eclipse Ti microscope and software to improve engraftment may help to advance the therapeutic efficacy and accessibility of islet transplantation across centers.

    PubMed

    Gmyr, Valery; Bonner, Caroline; Lukowiak, Bruno; Pawlowski, Valerie; Dellaleau, Nathalie; Belaich, Sandrine; Aluka, Isanga; Moermann, Ericka; Thevenet, Julien; Ezzouaoui, Rimed; Queniat, Gurvan; Pattou, Francois; Kerr-Conte, Julie

    2015-01-01

    Reliable assessment of islet viability, mass, and purity must be met prior to transplanting an islet preparation into patients with type 1 diabetes. The standard method for quantifying human islet preparations is by direct microscopic analysis of dithizone-stained islet samples, but this technique may be susceptible to inter-/intraobserver variability, which may induce false positive/negative islet counts. Here we describe a simple, reliable, automated digital image analysis (ADIA) technique for accurately quantifying islets into total islet number, islet equivalent number (IEQ), and islet purity before islet transplantation. Islets were isolated and purified from n = 42 human pancreata according to the automated method of Ricordi et al. For each preparation, three islet samples were stained with dithizone and expressed as IEQ number. Islets were analyzed manually by microscopy or automatically quantified using Nikon's inverted Eclipse Ti microscope with built-in NIS-Elements Advanced Research (AR) software. The AIDA method significantly enhanced the number of islet preparations eligible for engraftment compared to the standard manual method (p < 0.001). Comparisons of individual methods showed good correlations between mean values of IEQ number (r(2) = 0.91) and total islet number (r(2) = 0.88) and thus increased to r(2) = 0.93 when islet surface area was estimated comparatively with IEQ number. The ADIA method showed very high intraobserver reproducibility compared to the standard manual method (p < 0.001). However, islet purity was routinely estimated as significantly higher with the manual method versus the ADIA method (p < 0.001). The ADIA method also detected small islets between 10 and 50 µm in size. Automated digital image analysis utilizing the Nikon Instruments software is an unbiased, simple, and reliable teaching tool to comprehensively assess the individual size of each islet cell preparation prior to transplantation. Implementation of this technology to improve engraftment may help to advance the therapeutic efficacy and accessibility of islet transplantation across centers.

  16. Abbreviation of the Follow-Up NIH Stroke Scale Using Factor Analysis

    PubMed Central

    Raza, Syed Ali; Frankel, Michael R.; Rangaraju, Srikant

    2017-01-01

    Background The NIH Stroke Scale (NIHSS) is a 15-item measure of stroke-related neurologic deficits that, when measured at 24 h, is highly predictive of long-term functional outcome. We hypothesized that a simplified 24-h scale that incorporates the most predictive components of the NIHSS can retain prognostic accuracy and have improved interrater reliability. Methods In a post hoc analysis of the Interventional Management of Stroke-3 (IMS-3) trial, we performed principal component (PC) analysis to resolve the 24-h NIHSS into PCs. In the PCs that explained the largest proportions of variance, key variables were identified. Using these key variables, the prognostic accuracies (area under the curve [AUC]) for good outcome (3-month modified Rankin Scale [mRS] 0–2) and poor outcome (mRS 5–6) of various abbreviated NIHSS iterations were compared with the total 24-h NIHSS. The results were validated in the NINDS intravenous tissue plasminogen activator (NINDS-TPA) study cohort. Based on previously published data, interrater reliability of the abbreviated 24-h NIHSS (aNIHSS) was compared to the total 24-h NIHSS. Results In 545 IMS-3 participants, 2 PCs explained 60.8% of variance in the 24-h NIHSS. The key variables in PC1 included neglect, arm and leg weakness; while PC2 included level-of-consciousness (LOC) questions, LOC commands, and aphasia. A 3-variable aNIHSS (aphasia, neglect, arm weakness) retained excellent prognostic accuracy for good outcome (AUC = 0.90) as compared to the total 24-h NIHSS (AUC = 0.91), and it was more predictive (p < 0.001) than the baseline NIHSS (AUC = 0.73). The prognostic accuracy of the aNIHSS for good outcome was validated in the NINDS-TPA trial cohort (aNIHSS: AUC = 0.89 vs. total 24-h NIHSS: 0.92). An aNIHSS >9 predicted very poor outcomes (mRS 0–2: 0%, mRS 4–6: 98.5%). The estimated interrater reliability of the aNIHSS was higher than that of the total 24-h NIHSS across 6 published datasets (mean weighted kappa 0.80 vs. 0.73, p < 0.001). Conclusions At 24 h following ischemic stroke, aphasia, neglect, and arm weakness are the most prognostically relevant neurologic findings. The aNIHSS appears to have excellent prognostic accuracy with higher reliability and may be clinically useful. PMID:28968607

  17. Reliability measures of functional magnetic resonance imaging in a longitudinal evaluation of mild cognitive impairment.

    PubMed

    Zanto, Theodore P; Pa, Judy; Gazzaley, Adam

    2014-01-01

    As the aging population grows, it has become increasingly important to carefully characterize amnestic mild cognitive impairment (aMCI), a preclinical stage of Alzheimer's disease (AD). Functional magnetic resonance imaging (fMRI) is a valuable tool for monitoring disease progression in selectively vulnerable brain regions associated with AD neuropathology. However, the reliability of fMRI data in longitudinal studies of older adults with aMCI is largely unexplored. To address this, aMCI participants completed two visual working tasks, a Delayed-Recognition task and a One-Back task, on three separate scanning sessions over a three-month period. Test-retest reliability of the fMRI blood oxygen level dependent (BOLD) activity was assessed using an intraclass correlation (ICC) analysis approach. Results indicated that brain regions engaged during the task displayed greater reliability across sessions compared to regions that were not utilized by the task. During task-engagement, differential reliability scores were observed across the brain such that the frontal lobe, medial temporal lobe, and subcortical structures exhibited fair to moderate reliability (ICC=0.3-0.6), while temporal, parietal, and occipital regions exhibited moderate to good reliability (ICC=0.4-0.7). Additionally, reliability across brain regions was more stable when three fMRI sessions were used in the ICC calculation relative to two fMRI sessions. In conclusion, the fMRI BOLD signal is reliable across scanning sessions in this population and thus a useful tool for tracking longitudinal change in observational and interventional studies in aMCI. © 2013.

  18. A Confirmatory Factor Analysis of the Structure of Abbreviated Math Anxiety Scale

    PubMed Central

    Farrokhi, Farahman

    2011-01-01

    Objective The aim of this study is to explore the confirmatory factor analysis results of the Persian adaptation of Abbreviated Math Anxiety Scale (AMAS), proposed by Hopko, Mahadevan, Bare & Hunt. Method The validity and reliability assessments of the scale were performed on 298 college students chosen randomly from Tabriz University in Iran. The confirmatory factor analysis (CFA) was carried out to determine the factor structures of the Persian version of AMAS. Results As expected, the two-factor solution provided a better fit to the data than a single factor. Moreover, multi-group analyses showed that this two-factor structure was invariant across sex. Hence, AMAS provides an equally valid measure for use among college students. Conclusions Brief AMAS demonstrates adequate reliability and validity. The AMAS scores can be used to compare symptoms of math anxiety between male and female students. The study both expands and adds support to the existing body of math anxiety literature. PMID:22952521

  19. Factor structure and psychometric properties of the Fertility Problem Inventory–Short Form

    PubMed Central

    Zurlo, Maria Clelia; Cattaneo Della Volta, Maria Franscesca; Vallone, Federica

    2017-01-01

    The study analyses factor structure and psychometric properties of the Italian version of the Fertility Problem Inventory–Short Form. A sample of 206 infertile couples completed the Italian version of Fertility Problem Inventory (46 items) with demographics, State Anxiety Scale of State-Trait Anxiety Inventory (Form Y), Edinburgh Depression Scale and Dyadic Adjustment Scale, used to assess convergent and discriminant validity. Confirmatory factor analysis was unsatisfactory (comparative fit index = 0.87; Tucker-Lewis Index = 0.83; root mean square error of approximation = 0.17), and Cronbach’s α (0.95) revealed a redundancy of items. Exploratory factor analysis was carried out deleting cross-loading items, and Mokken scale analysis was applied to verify the items homogeneity within the reduced subscales of the questionnaire. The Fertility Problem Inventory–Short Form consists of 27 items, tapping four meaningful and reliable factors. Convergent and discriminant validity were confirmed. Findings indicated that the Fertility Problem Inventory–Short Form is a valid and reliable measure to assess infertility-related stress dimensions. PMID:29379625

  20. A comparison of restriction fragment length polymorphism, tetra primer amplification refractory mutation system PCR and unlabeled probe melting analysis for LTA+252 C>T SNP genotyping.

    PubMed

    Soler, Stephan; Rittore, Cécile; Touitou, Isabelle; Philibert, Laurent

    2011-02-20

    From the wide range of methods currently available for genotyping, we wished to identify a quick, reliable and affordable approach for routine use in our laboratory for LTA+252 C>T SNP screening. We set up and compared three genotyping methods for SNP detection: restriction fragment length polymorphism (RFLP), tetra primer amplification refractory mutation system PCR (TPAP) and unlabeled probe melting analysis (UPMA). The SNP model used was LTA+252 C>T, a cytokine gene polymorphism that has been associated with response to treatment in rheumatoid arthritis. The study was performed using 46 samples from healthy Caucasian volunteers. Allele and genotype distribution was similar to that previously described in the same population. All three genotyping methods showed good reproducibility and are suitable for a medium scale throughput molecular platform. UPMA was the most cost effective, reliable and safe method since it required the shortest technician time, could be performed in a single closed tube and involved automatic data analysis. This work is the first to compare these three genotyping techniques and provides evidence for UPMA being the method of choice for LTA+252 C>T SNP genotyping. Copyright © 2010 Elsevier B.V. All rights reserved.

  1. [Validity and reliability of Korean version of the Family Management Measure (Korean FaMM) for families with children having chronic illness].

    PubMed

    Kim, Dong Hee; Im, Yeo Jin

    2013-02-01

    To develop and test the validity and reliability of the Korean version of the Family Management Measure (Korean FaMM) to assess applicability for families with children having chronic illnesses. The Korean FaMM was articulated through forward-backward translation methods. Internal consistency reliability, construct and criterion validity were calculated using PASW WIN (19.0) and AMOS (20.0). Survey data were collected from 341 mothers of children suffering from chronic disease enrolled in a university hospital in Seoul, South Korea. The Korean version of FaMM showed reliable internal consistency with Cronbach's alpha for the total scale of .69-.91. Factor loadings of the 53 items on the six sub-scales ranged from 0.28-0.84. The model of six subscales for the Korean FaMM was validated by expiratory and confirmatory factor analysis (χ²<.001, RMR<.05, GFI, AGFI, NFI, NNFI>.08). Criterion validity compared to the Parental Stress Index (PSI) showed significant correlation. The findings of this study demonstrate that the Korean FaMM showed satisfactory construct and criterion validity and reliability. It is useful to measure Korean family's management style with their children who have a chronic illness.

  2. [Modification and evaluation of assessment of 
medication literacy].

    PubMed

    Zheng, Feng; Zhong, Zhuqing; Ding, Siqing; Luo, Aijing; Liu, Zina

    2016-11-28

    To translate and revise the Medication Literacy Assessment in English (MedLitRxSE-English) and evaluate its validity and reliability.
 Methods: We introduced MedLitRxSE-English from abroad. According to the principles of Brislin and culture adjustment, we revised it as a Chinese edition. Using random sampling method, from Oct, 2014 to Jan, 2015, 461 non-hospitalized patients from the outpatient departments of the top three hospitals in Changsha city were investigated. The reliability and validity of the scale was tested.
 Results: The test-retest reliability of the Chinese version for medication literacy scale was 0.885; the split reliability was 0.840; K-R was 0.820; the correlations between the assessment of medication literacy and the corresponding items were 0.427-0.587; the confirmatory factor analysis revealed overall good fit. Root mean square error of approximation (RMSEA), χ2/df, goodness of fit index (GFI) and comparative fit index (CFI) was 0.08, 3.06, 0.91 and 0.94, respectively. 
 Conclusion: The Chinese version for the assessment of medication literacy is in good reliability and validity, and it can be used to evaluate the medication literacy in our country.

  3. A 17-month time course study of human RNA and DNA degradation in body fluids under dry and humid environmental conditions.

    PubMed

    Sirker, Miriam; Schneider, Peter M; Gomes, Iva

    2016-11-01

    Blood, saliva, and semen are some of the forensically most relevant biological stains commonly found at crime scenes, which can often be of small size or challenging due to advanced decay. In this context, it is of great importance to possess reliable knowledge about the effects of degradation under different environmental conditions and to use appropriate methods for retrieving maximal information from limited sample amount. In the last decade, RNA analysis has been demonstrated to be a reliable approach identifying the cell or tissue type of an evidentiary body fluid trace. Hence, messenger RNA (mRNA) profiling is going to be implemented into forensic casework to supplement the routinely performed short tandem repeat (STR) analysis, and therefore, the ability to co-isolate RNA and DNA from the same sample is a prerequisite. The objective of this work was to monitor and compare the degradation process of both nucleic acids for human blood, saliva, and semen stains at three different concentrations, exposed to dry and humid conditions during a 17-month time period. This study also addressed the question whether there are relevant differences in the efficiency of automated, magnetic bead-based single DNA or RNA extraction methods compared to a manually performed co-extraction method using silica columns. Our data show that mRNA, especially from blood and semen, can be recovered over the entire time period surveyed without compromising the success of DNA profiling; mRNA analysis indicates to be a robust and reliable technique to identify the biological source of aged stain material. The co-extraction method appears to provide mRNA and DNA of sufficient quantity and quality for all different forensic investigation procedures. Humidity and accompanied mold formation are detrimental to both nucleic acids.

  4. Comparative effectiveness.

    PubMed

    Brown, Gary C; Brown, Melissa M

    2009-05-01

    To familiarize the clinician with the concept of comparative effectiveness. Recent data support the concept that utility analysis is the quality-of-life instrument best able to perform comparative effectiveness analyses. The use of time tradeoff utilities for comparative effectiveness analyses in interventions across diverse specialties of medicine can be undertaken with both excellent reliability and superior construct validity. Physicians should familiarize themselves with quality-of-life instruments that can be used to assess the comparative effectiveness of healthcare interventions. Rather than delegating comparative effectiveness to others, physicians must become involved in creating and implementing comparative effectiveness standards. Physician involvement is crucial for the best interests of patients, as physicians most intimately understand the complexities and nuances associated with healthcare interventions.

  5. Interrater reliability of the Australasian Triage Scale for mental health patients.

    PubMed

    Creaton, Anne; Liew, Don; Knott, Jonathan; Wright, Melissa

    2008-12-01

    To evaluate interrater reliability of the Australasian Triage Scale (ATS) for mental health patients in ED. In a prospective descriptive study, triage nurses were shown video vignettes of simulated scenarios of mental health presentations. Trieurs (raters) were asked to allocate an ATS category (rating) to each case. The primary outcome was the degree of interrater reliability for each simulated case. Also assessed were differences between raters or settings, grouped by level of ED activity, state of origin, hospital type and familiarity with appropriate guidelines. Chi-squared analysis was used for independent categorical variables; the Friedman test was used to compare the triage scores between busy and quiet ED scenarios. Ordinal data results were compared using opartchi. All 90 eligible participants were enrolled. The highest interrater concordance was 65.6% whereas the lowest interrater concordance was 53.3%. Significant association occurred between the distribution of triage ratings, ED activity level and the state of origin. A busy ED resulted in the assignment of a more urgent ATS category and decrease in concordance. There is a need to develop and implement a validated, standardized national triage tool for mental health patients. The ATS per se is insufficient to ensure acceptable interrater reliability, particularly during busy periods in the ED, and between states. Given the influence the ATS has on key outcomes, it is imperative for this tool to be robust.

  6. MR signal-fat-fraction analysis and T2* weighted imaging measure BAT reliably on humans without cold exposure.

    PubMed

    Holstila, Milja; Pesola, Marko; Saari, Teemu; Koskensalo, Kalle; Raiko, Juho; Borra, Ronald J H; Nuutila, Pirjo; Parkkola, Riitta; Virtanen, Kirsi A

    2017-05-01

    Brown adipose tissue (BAT) is compositionally distinct from white adipose tissue (WAT) in terms of triglyceride and water content. In adult humans, the most significant BAT depot is localized in the supraclavicular area. Our aim is to differentiate brown adipose tissue from white adipose tissue using fat T2* relaxation time mapping and signal-fat-fraction (SFF) analysis based on a commercially available modified 2-point-Dixon (mDixon) water-fat separation method. We hypothesize that magnetic resonance (MR) imaging can reliably measure BAT regardless of the cold-induced metabolic activation, with BAT having a significantly higher water and iron content compared to WAT. The supraclavicular area of 13 volunteers was studied on 3T PET-MRI scanner using T2* relaxation time and SFF mapping both during cold exposure and at ambient temperature; and 18 F-FDG PET during cold exposure. Volumes of interest (VOIs) were defined semiautomatically in the supraclavicular fat depot, subcutaneous WAT and muscle. The supraclavicular fat depot (assumed to contain BAT) had a significantly lower SFF and fat T2* relaxation time compared to subcutaneous WAT. Cold exposure did not significantly affect MR-based measurements. SFF and T2* values measured during cold exposure and at ambient temperature correlated inversely with the glucose uptake measured by 18 F-FDG PET. Human BAT can be reliably and safely assessed using MRI without cold activation and PET-related radiation exposure. Copyright © 2017 Elsevier Inc. All rights reserved.

  7. Performance of 2-D shear wave elastography in liver fibrosis assessment compared with serologic tests and transient elastography in clinical routine.

    PubMed

    Bota, Simona; Paternostro, Rafael; Etschmaier, Alexandra; Schwarzer, Remy; Salzl, Petra; Mandorfer, Mattias; Kienbacher, Christian; Ferlitsch, Monika; Reiberger, Thomas; Trauner, Michael; Peck-Radosavljevic, Markus; Ferlitsch, Arnulf

    2015-09-01

    Liver stiffness values assessed with 2-D shear wave elastography (SWE), transient elastography (TE) and simple serologic tests were compared with respect to non-invasive assessment in a cohort of 127 consecutive patients with chronic liver diseases. The rate of reliable liver stiffness measurements was significantly higher with 2-D SWE than with TE: 99.2% versus 74.8%, p < 0.0001 (different reliability criteria used, according to current recommendations). In univariate analysis, liver stiffness measured with 2-D SWE correlated best with fibrosis stage estimated with TE (r = 0.699, p < 0.0001), followed by Forns score (r = 0.534, p < 0.0001) and King's score (r = 0.512, p < 0.0001). However, in multivariate analysis, only 2-D SWE-measured values remained correlated with fibrosis stage (p < 0.0001). The optimal 2-D SWE cutoff values for predicting significant fibrosis were 8.03 kPa for fibrosis stage ≥2 (area under the receiver operating characteristic curve = 0.832) and 13.1 kPa for fibrosis stage 4 (area under the receiver operating characteristic curve = 0.915), respectively. In conclusion, 2-D SWE can be used to obtain reliable liver stiffness measurements in almost all patients and performs very well in predicting the presence of liver cirrhosis. Copyright © 2015 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  8. Culture-Independent Analysis of Probiotic Products by Denaturing Gradient Gel Electrophoresis

    PubMed Central

    Temmerman, R.; Scheirlinck, I.; Huys, G.; Swings, J.

    2003-01-01

    In order to obtain functional and safe probiotic products for human consumption, fast and reliable quality control of these products is crucial. Currently, analysis of most probiotics is still based on culture-dependent methods involving the use of specific isolation media and identification of a limited number of isolates, which makes this approach relatively insensitive, laborious, and time-consuming. In this study, a collection of 10 probiotic products, including four dairy products, one fruit drink, and five freeze-dried products, were subjected to microbial analysis by using a culture-independent approach, and the results were compared with the results of a conventional culture-dependent analysis. The culture-independent approach involved extraction of total bacterial DNA directly from the product, PCR amplification of the V3 region of the 16S ribosomal DNA, and separation of the amplicons on a denaturing gradient gel. Digital capturing and processing of denaturing gradient gel electrophoresis (DGGE) band patterns allowed direct identification of the amplicons at the species level. This whole culture-independent approach can be performed in less than 30 h. Compared with culture-dependent analysis, the DGGE approach was found to have a much higher sensitivity for detection of microbial strains in probiotic products in a fast, reliable, and reproducible manner. Unfortunately, as reported in previous studies in which the culture-dependent approach was used, a rather high percentage of probiotic products suffered from incorrect labeling and yielded low bacterial counts, which may decrease their probiotic potential. PMID:12513998

  9. Intra-instrument reliability of 4 goniometers.

    PubMed

    Pringle, R Kevin

    2003-01-01

    Cervical spine ROM movements taken accurately with reliable measuring devices are important in outcome measures as well as in measuring disability. To compare the active cervical spine ROM in healthy young adult population using 4 different goniometers. Subjects were tested during active cervical spine ROM. The devices were a single hinge inclinometer, single bubble carpenter's inclinometer, dual bubble goniometers and Cybex EDI 320 electrical inclinometer. All subjects were tested for rotational limits along each of the orthogonal axes of movement. There are 3 trials for each movement direction, except rotation was not measured with the Cybex as per manual suggestions. The subjects were randomly assigned to the sequence of devices. Twenty-seven student volunteers (19 men and 8 women) were tested. Ages ranged from 21 to 41, mean age of 27.6 years of age. Active cervical spine ROM trials for each measurement was used to calculate mean and standard deviation. An overall analysis of variance (ANOVA) and Bonferroni adjusted T-test were determined in order to calculate reliability and significance. The cost of the instruments were not used in determining reliability or significance. The single hinge inclinometer was found to be a reliable measure but not likely valid. The Cybex EDI 320 was found to be the best measuring device; however, the 2 instruments whose cost were in-between the single hinge inclinometer and the electrical goniometer were just as reliable as the more expensive device. The AMA Guides of Impairment were used as the normative data to compare these devices. Since the devices could measure reliably, whether expensive or more cost effective for students they would likely make adequate devices for training students on the methods for measuring ROM. There is previous data to suggest that older populations have gender differences and age differences with ROM. This study could not measure that and would make a useful follow-up study.

  10. Validity and Reliability of a Digital Inclinometer to Assess Knee Joint Position Sense in a Closed Kinetic Chain.

    PubMed

    Romero-Franco, Natalia; Montaño-Munuera, Juan Antonio; Jiménez-Reyes, Pedro

    2017-01-01

    Knee joint position sense (JPS) is a key parameter for optimum performance in many sports but is frequently negatively affected by injuries and/or fatigue during training sessions. Although evaluation of JPS may provide key information to reduce the risk of injury, it often requires expensive and/or complex tools that make monitoring proprioceptive deterioration difficult. To analyze the validity and reliability of a digital inclinometer to measure knee JPS in a closed kinetic chain (CKC). The validity and intertester and intratester reliability of a digital inclinometer for measuring knee JPS were assessed. Biomechanics laboratory. 10 athletes (5 men and 5 women; 26.2 ± 1.3 y, 71.7 ± 12.4 kg; 1.75 ± 0.09 m; 23.5 ± 3.9 kg/m 2 ). Knee JPS was measured in a CKC. Absolute angular error (AAE) of knee JPS in a CKC. Intraclass correlation coefficient (ICC) and standard error of the mean (SEM) were calculated to determine the validity and reliability of the inclinometer. Data showed that the inclinometer had a high level of validity compared with an isokinetic dynamometer (ICC = 1.0, SEM = 1.39, p < 0.001), and there was very good intra- and inter-tester reliability for reading the inclinometer (ICC = 1.0, SEM = 0.85, p < 0.001). Compared with AutoCAD video analysis, inclinometer validity was very high (ICC = 0.980, SEM = 3.46, p < 0.001) for measuring AAE during knee JPS in a CKC. In addition, the intertester reliability of the inclinometer for obtaining AAE was very high (ICC = .994, SEM = 1.67, p < 0.001). The inclinometer provides a valid and reliable method for assessing knee JPS in a CKC. Health and sports professionals could take advantage of this tool to monitor proprioceptive deterioration in athletes.

  11. The welfare effects of integrating renewable energy into electricity markets

    NASA Astrophysics Data System (ADS)

    Lamadrid, Alberto J.

    The challenges of deploying more renewable energy sources on an electric grid are caused largely by their inherent variability. In this context, energy storage can help make the electric delivery system more reliable by mitigating this variability. This thesis analyzes a series of models for procuring electricity and ancillary services for both individuals and social planners with high penetrations of stochastic wind energy. The results obtained for an individual decision maker using stochastic optimization are ambiguous, with closed form solutions dependent on technological parameters, and no consideration of the system reliability. The social planner models correctly reflect the effect of system reliability, and in the case of a Stochastic, Security Constrained Optimal Power Flow (S-SC-OPF or SuperOPF), determine reserve capacity endogenously so that system reliability is maintained. A single-period SuperOPF shows that including ramping costs in the objective function leads to more wind spilling and increased capacity requirements for reliability. However, this model does not reflect the inter temporal tradeoffs of using Energy Storage Systems (ESS) to improve reliability and mitigate wind variability. The results with the multiperiod SuperOPF determine the optimum use of storage for a typical day, and compare the effects of collocating ESS at wind sites with the same amount of storage (deferrable demand) located at demand centers. The collocated ESS has slightly lower operating costs and spills less wind generation compared to deferrable demand, but the total amount of conventional generating capacity needed for system adequacy is higher. In terms of the total system costs, that include the capital cost of conventional generating capacity, the costs with deferrable demand is substantially lower because the daily demand profile is flattened and less conventional generation capacity is then needed for reliability purposes. The analysis also demonstrates that the optimum daily pattern of dispatch and reserves is seriously distorted if the stochastic characteristics of wind generation are ignored.

  12. Validity and Reliability of a Digital Inclinometer to Assess Knee Joint Position Sense in an Open Kinetic Chain.

    PubMed

    Romero-Franco, Natalia; Montaño-Munuera, Juan Antonio; Fernández-Domínguez, Juan Carlos; Jiménez-Reyes, Pedro

    2017-12-18

    New methods are being validated to easily evaluate the knee joint position sense (JPS) due to its role in sports movement and the risk of injury. However, no studies to date have considered the open kinetic chain (OKC) technique, despite the biomechanical differences compared to closed kinetic chain movements. To analyze the validity and reliability of a digital inclinometer to measure the knee JPS in the OKC movement. The validity, inter-tester and intra-tester reliability of a digital inclinometer for measuring knee JPS were evaluated. Sports research laboratory. Eighteen athletes (11 males and 7 females; 28.4 ± 6.6 years; 71.9 ± 14.0 kg; 1.77 ± 0.09 m; 22.8 ± 3.2 kg/m 2 ) voluntary participated in this study. Absolute angular error (AAE), relative angular error (RAE) and variable angular error (VAE) of knee JPS in an OKC. Intraclass correlation coefficient (ICC) and standard error of the mean (SEM) were calculated to determine the validity and reliability of the inclinometer. Data showed excellent validity of the inclinometer to obtain proprioceptive errors compared to the video analysis in JPS tasks (AAE: ICC = 0.981, SEM = 0.08; RAE: ICC = 0.974, SEM = 0.12; VAE: ICC = 0.973, SEM = 0.07). Inter-tester reliability was also excellent for all the proprioceptive errors (AAE: ICC = 0.967, SEM = 0.04; RAE: ICC = 0.974, SEM = 0.03; VAE: ICC = 0.939, SEM = 0.08). Similar results were obtained for intra-tester reliability (AAE: ICC = 0.861, SEM = 0.1; RAE: ICC = 0.894, SEM = 0.1; VAE: ICC = 0.700, SEM = 0.2). The digital inclinometer is a valid and reliable method to assess the knee JPS in OKC. Sport professionals may evaluate the knee JPS to monitor its deterioration during training or improvements throughout the rehabilitation process.

  13. An Analysis of the Ratings and Interrater Reliability of High School Band Contests

    ERIC Educational Resources Information Center

    Hash, Phillip M.

    2012-01-01

    The purpose of this study was to examine procedures for analyzing ratings of large-group festivals and provide data with which to compare results from similar events. Data consisted of ratings from senior division concert band contests sponsored by the South Carolina Band Directors Association from 2008 to 2010. Three concert-performance and two…

  14. Video Analysis of Mother-Child Interactions: Does the Role of Experience Affect the Accuracy and Reliability of Clinical Observations?

    ERIC Educational Resources Information Center

    Choo, Dawn; Dettman, Shani J.

    2016-01-01

    During the pre- and post-implant habilitation process, mothers of children using cochlear implants may be coached by clinicians to use appropriate communicative strategies during play according to the family's choice of communication approach. The present study compared observations made by experienced and inexperienced individuals in the analysis…

  15. Reliability and validity of gait analysis by android-based smartphone.

    PubMed

    Nishiguchi, Shu; Yamada, Minoru; Nagai, Koutatsu; Mori, Shuhei; Kajiwara, Yuu; Sonoda, Takuya; Yoshimura, Kazuya; Yoshitomi, Hiroyuki; Ito, Hiromu; Okamoto, Kazuya; Ito, Tatsuaki; Muto, Shinyo; Ishihara, Tatsuya; Aoyama, Tomoki

    2012-05-01

    Smartphones are very common devices in daily life that have a built-in tri-axial accelerometer. Similar to previously developed accelerometers, smartphones can be used to assess gait patterns. However, few gait analyses have been performed using smartphones, and their reliability and validity have not been evaluated yet. The purpose of this study was to evaluate the reliability and validity of a smartphone accelerometer. Thirty healthy young adults participated in this study. They walked 20 m at their preferred speeds, and their trunk accelerations were measured using a smartphone and a tri-axial accelerometer that was secured over the L3 spinous process. We developed a gait analysis application and installed it in the smartphone to measure the acceleration. After signal processing, we calculated the gait parameters of each measurement terminal: peak frequency (PF), root mean square (RMS), autocorrelation peak (AC), and coefficient of variance (CV) of the acceleration peak intervals. Remarkable consistency was observed in the test-retest reliability of all the gait parameter results obtained by the smartphone (p<0.001). All the gait parameter results obtained by the smartphone showed statistically significant and considerable correlations with the same parameter results obtained by the tri-axial accelerometer (PF r=0.99, RMS r=0.89, AC r=0.85, CV r=0.82; p<0.01). Our study indicates that the smartphone with gait analysis application used in this study has the capacity to quantify gait parameters with a degree of accuracy that is comparable to that of the tri-axial accelerometer.

  16. Reliability of Corneal Dynamic Scheimpflug Analyser Measurements in Virgin and Post-PRK Eyes

    PubMed Central

    Chen, Xiangjun; Stojanovic, Aleksandar; Hua, Yanjun; Eidet, Jon Roger; Hu, Di; Wang, Jingting; Utheim, Tor Paaske

    2014-01-01

    Purpose To determine the measurement reliability of CorVis ST, a dynamic Scheimpflug analyser, in virgin and post-photorefractive keratectomy (PRK) eyes and compare the results between these two groups. Methods Forty virgin eyes and 42 post-PRK eyes underwent CorVis ST measurements performed by two technicians. Repeatability was evaluated by comparing three consecutive measurements by technician A. Reproducibility was determined by comparing the first measurement by technician A with one performed by technician B. Intraobserver and interobserver intraclass correlation coefficients (ICCs) were calculated. Univariate analysis of covariance (ANCOVA) was used to compare measured parameters between virgin and post-PRK eyes. Results The intraocular pressure (IOP), central corneal thickness (CCT) and 1st applanation time demonstrated good intraobserver repeatability and interobserver reproducibility (ICC≧0.90) in virgin and post-PRK eyes. The deformation amplitude showed a good or close to good repeatability and reproducibility in both groups (ICC≧0.88). The CCT correlated positively with 1st applanation time (r = 0.437 and 0.483, respectively, p<0.05) and negatively with deformation amplitude (r = −0.384 and −0.375, respectively, p<0.05) in both groups. Compared to post-PRK eyes, virgin eyes showed longer 1st applanation time (7.29±0.21 vs. 6.96±0.17 ms, p<0.05) and lower deformation amplitude (1.06±0.07 vs. 1.17±0.08 mm, p<0.05). Conclusions CorVis ST demonstrated reliable measurements for CCT, IOP, and 1st applanation time, as well as relatively reliable measurement for deformation amplitude in both virgin and post-PRK eyes. There were differences in 1st applanation time and deformation amplitude between virgin and post-PRK eyes, which may reflect corneal biomechanical changes occurring after the surgery in the latter. PMID:25302580

  17. Efficient finite element modelling for the investigation of the dynamic behaviour of a structure with bolted joints

    NASA Astrophysics Data System (ADS)

    Omar, R.; Rani, M. N. Abdul; Yunus, M. A.; Mirza, W. I. I. Wan Iskandar; Zin, M. S. Mohd

    2018-04-01

    A simple structure with bolted joints consists of the structural components, bolts and nuts. There are several methods to model the structures with bolted joints, however there is no reliable, efficient and economic modelling methods that can accurately predict its dynamics behaviour. Explained in this paper is an investigation that was conducted to obtain an appropriate modelling method for bolted joints. This was carried out by evaluating four different finite element (FE) models of the assembled plates and bolts namely the solid plates-bolts model, plates without bolt model, hybrid plates-bolts model and simplified plates-bolts model. FE modal analysis was conducted for all four initial FE models of the bolted joints. Results of the FE modal analysis were compared with the experimental modal analysis (EMA) results. EMA was performed to extract the natural frequencies and mode shapes of the test physical structure with bolted joints. Evaluation was made by comparing the number of nodes, number of elements, elapsed computer processing unit (CPU) time, and the total percentage of errors of each initial FE model when compared with EMA result. The evaluation showed that the simplified plates-bolts model could most accurately predict the dynamic behaviour of the structure with bolted joints. This study proved that the reliable, efficient and economic modelling of bolted joints, mainly the representation of the bolting, has played a crucial element in ensuring the accuracy of the dynamic behaviour prediction.

  18. Reliability generalization study of the Yale-Brown Obsessive-Compulsive Scale for children and adolescents.

    PubMed

    López-Pina, José Antonio; Sánchez-Meca, Julio; López-López, José Antonio; Marín-Martínez, Fulgencio; Núñez-Núñez, Rosa Ma; Rosa-Alcázar, Ana I; Gómez-Conesa, Antonia; Ferrer-Requena, Josefa

    2015-01-01

    The Yale-Brown Obsessive-Compulsive Scale for children and adolescents (CY-BOCS) is a frequently applied test to assess obsessive-compulsive symptoms. We conducted a reliability generalization meta-analysis on the CY-BOCS to estimate the average reliability, search for reliability moderators, and propose a predictive model that researchers and clinicians can use to estimate the expected reliability of the CY-BOCS scores. A total of 47 studies reporting a reliability coefficient with the data at hand were included in the meta-analysis. The results showed good reliability and a large variability associated to the standard deviation of total scores and sample size.

  19. Ultrasound-based motor control training for the pelvic floor pre- and post-prostatectomy: Scoring reliability and skill acquisition.

    PubMed

    Doorbar-Baptist, Stuart; Adams, Roger; Rebbeck, Trudy

    2017-04-01

    This study documents a protocol designed to evaluate pelvic floor motor control in men with prostate cancer. It also aims to evaluate the reliability of therapists in rating motor control of pelvic floor muscles (PFMs) using real time ultrasound imaging (RUSI) video clips. We further determine predictors of acquiring motor control. Ninety-one men diagnosed with prostate cancer attending a physiotherapy clinic for pelvic floor exercises were taught detailed pelvic floor motor control exercises by a physiotherapist using trans-abdominal RUSI for biofeedback. A new protocol to rate motor control skill acquisition was developed. Three independent physiotherapists assessed motor control skill attainment by viewing RUSI videos of the contractions. Inter-rater reliability was evaluated using intra-class correlation coefficients. Logistic regression analysis was conducted to identify predictors of successful skill attainment. Acquisition of the skill was compared between pre- and post-operative participants using an independent-group t-test. There was good reliability for rating the RUSI video clips (ICC 0.73 (95%CI 0.59-0.82)) for experienced therapists. Having low BMI and being seen pre-operatively predicted motor skill attainment, accounting for 46.3% of the variance. Significantly more patients trained pre-operatively acquired the skill of pelvic floor control compared with patients initially seen post-operatively (OR 11.87, 95%CI 1.4 to 99.5, p = 0.02). A new protocol to evaluate attainment of pelvic floor control in men with prostate cancer can be assessed reliably from RUSI images, and is most effectively delivered pre-operatively.

  20. Three-dimensional facial anthropometry of unilateral cleft lip infants with a structured light scanning system.

    PubMed

    Li, Guanghui; Wei, Jianhua; Wang, Xi; Wu, Guofeng; Ma, Dandan; Wang, Bo; Liu, Yanpu; Feng, Xinghua

    2013-08-01

    Cleft lip in the presence or absence of a cleft palate is a major public health problem. However, few studies have been published concerning the soft-tissue morphology of cleft lip infants. Currently, obtaining reliable three-dimensional (3D) surface models of infants remains a challenge. The aim of this study was to investigate a new way of capturing 3D images of cleft lip infants using a structured light scanning system. In addition, the accuracy and precision of the acquired facial 3D data were validated and compared with direct measurements. Ten unilateral cleft lip patients were enrolled in the study. Briefly, 3D facial images of the patients were acquired using a 3D scanner device before and after the surgery. Fourteen items were measured by direct anthropometry and 3D image software. The accuracy and precision of the 3D system were assessed by comparative analysis. The anthropometric data obtained using the 3D method were in agreement with the direct anthropometry measurements. All data calculated by the software were 'highly reliable' or 'reliable', as defined in the literature. The localisation of four landmarks was not consistent in repeated experiments of inter-observer reliability in preoperative images (P<0.05), while the intra-observer reliability in both pre- and postoperative images was good (P>0.05). The structured light scanning system is proven to be a non-invasive, accurate and precise method in cleft lip anthropometry. Copyright © 2013 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  1. The Modified Femoral Neck-Shaft Angle: Age- and Sex-Dependent Reference Values and Reliability Analysis

    PubMed Central

    Jostmeier, Janine; Haneder, Stefan; Dargel, Jens; Eysel, Peer; Lechler, Philipp

    2016-01-01

    Background. The femoral neck-shaft angle (NSA) is of high importance for the diagnostics and treatment of various conditions of the hip. However, rotational effects limit its precision and applicability using plain radiographs. This study introduces a novel method to measure the femoral NSA: the modified NSA (mNSA), possibly being less susceptible against rotational effects compared to the conventional NSA. Patients and Methods. The method of measurement is described and its applicability was tested in 400 pelvis computed tomography scans (800 hips). Age- and gender-dependent reference values are given and intra- and interrater reliability are analyzed. Results. The mean age of all 400 patients (800 hips) was 54.32 years (18–100, SD 22.05 years). The mean mNSA was 147.0° and the 95% confidence interval was 146.7°–147.4°. Differences of the mNSA between sexes, age groups, and sides were nonsignificant. The absolute difference between NSA and mNSA was 16.3° (range 3–31°; SD 4.4°); the correlation was high (0.738; p < 0.001). Overall, the intra- and interrater reliability were excellent for the mNSA. Interpretation. We introduced a novel concept for the analysis of the neck-shaft angle. The high reliability of the measurement has been proven and its robustness to hip rotation was demonstrated. PMID:28070521

  2. The Modified Femoral Neck-Shaft Angle: Age- and Sex-Dependent Reference Values and Reliability Analysis.

    PubMed

    Boese, Christoph Kolja; Frink, Michael; Jostmeier, Janine; Haneder, Stefan; Dargel, Jens; Eysel, Peer; Lechler, Philipp

    2016-01-01

    Background . The femoral neck-shaft angle (NSA) is of high importance for the diagnostics and treatment of various conditions of the hip. However, rotational effects limit its precision and applicability using plain radiographs. This study introduces a novel method to measure the femoral NSA: the modified NSA (mNSA), possibly being less susceptible against rotational effects compared to the conventional NSA. Patients and Methods . The method of measurement is described and its applicability was tested in 400 pelvis computed tomography scans (800 hips). Age- and gender-dependent reference values are given and intra- and interrater reliability are analyzed. Results . The mean age of all 400 patients (800 hips) was 54.32 years (18-100, SD 22.05 years). The mean mNSA was 147.0° and the 95% confidence interval was 146.7°-147.4°. Differences of the mNSA between sexes, age groups, and sides were nonsignificant. The absolute difference between NSA and mNSA was 16.3° (range 3-31°; SD 4.4°); the correlation was high (0.738; p < 0.001). Overall, the intra- and interrater reliability were excellent for the mNSA. Interpretation . We introduced a novel concept for the analysis of the neck-shaft angle. The high reliability of the measurement has been proven and its robustness to hip rotation was demonstrated.

  3. A New Reliability Analysis Model of the Chegongzhuang Heat-Supplying Tunnel Structure Considering the Coupling of Pipeline Thrust and Thermal Effect

    PubMed Central

    Zhang, Jiawen; He, Shaohui; Wang, Dahai; Liu, Yangpeng; Yao, Wenbo; Liu, Xiabing

    2018-01-01

    Based on the operating Chegongzhuang heat-supplying tunnel in Beijing, the reliability of its lining structure under the action of large thrust and thermal effect is studied. According to the characteristics of a heat-supplying tunnel service, a three-dimensional numerical analysis model was established based on the mechanical tests on the in-situ specimens. The stress and strain of the tunnel structure were obtained before and after the operation. Compared with the field monitoring data, the rationality of the model was verified. After extracting the internal force of the lining structure, the improved method of subset simulation was proposed as the performance function to calculate the reliability of the main control section of the tunnel. In contrast to the traditional calculation method, the analytic relationship between the sample numbers in the subset simulation method and Monte Carlo method was given. The results indicate that the lining structure is greatly influenced by coupling in the range of six meters from the fixed brackets, especially the tunnel floor. The improved subset simulation method can greatly save computation time and improve computational efficiency under the premise of ensuring the accuracy of calculation. It is suitable for the reliability calculation of tunnel engineering, because “the lower the probability, the more efficient the calculation.” PMID:29401691

  4. Reliability, Convergent Validity and Time Invariance of Default Mode Network Deviations in Early Adult Major Depressive Disorder.

    PubMed

    Bessette, Katie L; Jenkins, Lisanne M; Skerrett, Kristy A; Gowins, Jennifer R; DelDonno, Sophie R; Zubieta, Jon-Kar; McInnis, Melvin G; Jacobs, Rachel H; Ajilore, Olusola; Langenecker, Scott A

    2018-01-01

    There is substantial variability across studies of default mode network (DMN) connectivity in major depressive disorder, and reliability and time-invariance are not reported. This study evaluates whether DMN dysconnectivity in remitted depression (rMDD) is reliable over time and symptom-independent, and explores convergent relationships with cognitive features of depression. A longitudinal study was conducted with 82 young adults free of psychotropic medications (47 rMDD, 35 healthy controls) who completed clinical structured interviews, neuropsychological assessments, and 2 resting-state fMRI scans across 2 study sites. Functional connectivity analyses from bilateral posterior cingulate and anterior hippocampal formation seeds in DMN were conducted at both time points within a repeated-measures analysis of variance to compare groups and evaluate reliability of group-level connectivity findings. Eleven hyper- (from posterior cingulate) and 6 hypo- (from hippocampal formation) connectivity clusters in rMDD were obtained with moderate to adequate reliability in all but one cluster (ICC's range = 0.50 to 0.76 for 16 of 17). The significant clusters were reduced with a principle component analysis (5 components obtained) to explore these connectivity components, and were then correlated with cognitive features (rumination, cognitive control, learning and memory, and explicit emotion identification). At the exploratory level, for convergent validity, components consisting of posterior cingulate with cognitive control network hyperconnectivity in rMDD were related to cognitive control (inverse) and rumination (positive). Components consisting of anterior hippocampal formation with social emotional network and DMN hypoconnectivity were related to memory (inverse) and happy emotion identification (positive). Thus, time-invariant DMN connectivity differences exist early in the lifespan course of depression and are reliable. The nuanced results suggest a ventral within-network hypoconnectivity associated with poor memory and a dorsal cross-network hyperconnectivity linked to poorer cognitive control and elevated rumination. Study of early course remitted depression with attention to reliability and symptom independence could lead to more readily translatable clinical assessment tools for biomarkers.

  5. The impact of chimerism in DNA-based forensic sex determination analysis.

    PubMed

    George, Renjith; Donald, Preethy Mary; Nagraj, Sumanth Kumbargere; Idiculla, Jose Joy; Hj Ismail, Rashid

    2013-01-01

    Sex determination is the most important step in personal identification in forensic investigations. DNA-based sex determination analysis is comparatively more reliable than the other conventional methods of sex determination analysis. Advanced technology like real-time polymerase chain reaction (PCR) offers accurate and reproducible results and is at the level of legal acceptance. But still there are situations like chimerism where an individual possess both male and female specific factors together in their body. Sex determination analysis in such cases can give erroneous results. This paper discusses the phenomenon of chimerism and its impact on sex determination analysis in forensic investigations.

  6. Alternative Methods for Calculating Intercoder Reliability in Content Analysis: Kappa, Weighted Kappa and Agreement Charts Procedures.

    ERIC Educational Resources Information Center

    Kang, Namjun

    If content analysis is to satisfy the requirement of objectivity, measures and procedures must be reliable. Reliability is usually measured by the proportion of agreement of all categories identically coded by different coders. For such data to be empirically meaningful, a high degree of inter-coder reliability must be demonstrated. Researchers in…

  7. Interactive Reliability Model for Whisker-toughened Ceramics

    NASA Technical Reports Server (NTRS)

    Palko, Joseph L.

    1993-01-01

    Wider use of ceramic matrix composites (CMC) will require the development of advanced structural analysis technologies. The use of an interactive model to predict the time-independent reliability of a component subjected to multiaxial loads is discussed. The deterministic, three-parameter Willam-Warnke failure criterion serves as the theoretical basis for the reliability model. The strength parameters defining the model are assumed to be random variables, thereby transforming the deterministic failure criterion into a probabilistic criterion. The ability of the model to account for multiaxial stress states with the same unified theory is an improvement over existing models. The new model was coupled with a public-domain finite element program through an integrated design program. This allows a design engineer to predict the probability of failure of a component. A simple structural problem is analyzed using the new model, and the results are compared to existing models.

  8. Reliability analysis of multicellular system architectures for low-cost satellites

    NASA Astrophysics Data System (ADS)

    Erlank, A. O.; Bridges, C. P.

    2018-06-01

    Multicellular system architectures are proposed as a solution to the problem of low reliability currently seen amongst small, low cost satellites. In a multicellular architecture, a set of independent k-out-of-n systems mimic the cells of a biological organism. In order to be beneficial, a multicellular architecture must provide more reliability per unit of overhead than traditional forms of redundancy. The overheads include power consumption, volume and mass. This paper describes the derivation of an analytical model for predicting a multicellular system's lifetime. The performance of such architectures is compared against that of several common forms of redundancy and proven to be beneficial under certain circumstances. In addition, the problem of peripheral interfaces and cross-strapping is investigated using a purpose-developed, multicellular simulation environment. Finally, two case studies are presented based on a prototype cell implementation, which demonstrate the feasibility of the proposed architecture.

  9. Development of robust flexible OLED encapsulations using simulated estimations and experimental validations

    NASA Astrophysics Data System (ADS)

    Lee, Chang-Chun; Shih, Yan-Shin; Wu, Chih-Sheng; Tsai, Chia-Hao; Yeh, Shu-Tang; Peng, Yi-Hao; Chen, Kuang-Jung

    2012-07-01

    This work analyses the overall stress/strain characteristic of flexible encapsulations with organic light-emitting diode (OLED) devices. A robust methodology composed of a mechanical model of multi-thin film under bending loads and related stress simulations based on nonlinear finite element analysis (FEA) is proposed, and validated to be more reliable compared with related experimental data. With various geometrical combinations of cover plate, stacked thin films and plastic substrate, the position of the neutral axis (NA) plate, which is regarded as a key design parameter to minimize stress impact for the concerned OLED devices, is acquired using the present methodology. The results point out that both the thickness and mechanical properties of the cover plate help in determining the NA location. In addition, several concave and convex radii are applied to examine the reliable mechanical tolerance and to provide an insight into the estimated reliability of foldable OLED encapsulations.

  10. Evaluation of the psychometric properties of the main meal quality index when applied in the UK population.

    PubMed

    Gorgulho, B M; Pot, G K; Marchioni, D M

    2017-05-01

    The aim of this study was to evaluate the validity and reliability of the Main Meal Quality Index when applied on the UK population. The indicator was developed to assess meal quality in different populations, and is composed of 10 components: fruit, vegetables (excluding potatoes), ratio of animal protein to total protein, fiber, carbohydrate, total fat, saturated fat, processed meat, sugary beverages and desserts, and energy density, resulting in a score range of 0-100 points. The performance of the indicator was measured using strategies for assessing content validity, construct validity, discriminant validity and reliability, including principal component analysis, linear regression models and Cronbach's alpha. The indicator presented good reliability. The Main Meal Quality Index has been shown to be valid for use as an instrument to evaluate, monitor and compare the quality of meals consumed by adults in the United Kingdom.

  11. Psychometric testing of the modified Care Dependency Scale among hospitalized school-aged children in Germany.

    PubMed

    Tork, Hanan; Lohrmann, Christa; Dassen, Theo

    2008-03-01

    The objectives of this study were to examine the psychometric properties of the modified Care Dependency Scale in a pediatric setting and to explore the extent of dependency of school-aged children regarding their self-care. The data were collected from 130 hospitalized children, aged 6-12 years. The reliability was determined by Cronbach's alpha, which showed a high level of consistency. The subsequent inter-rater reliability revealed moderate-to-substantial agreement. The criterion-related validity was tested by comparing the sum scores of the Care Dependency Scale for Paediatrics and the Visual Analog Scale. Factor analysis was used to investigate the construct validity and resulted in a one-factor solution. In conclusion, this study provides evidence that the Care Dependency Scale for Paediatrics is a valid and reliable measure that offers a comprehensive assessment from a nursing perspective and enables nurses to help children acquire independence.

  12. Overview of RICOR's reliability theoretical analysis, accelerated life demonstration test results and verification by field data

    NASA Astrophysics Data System (ADS)

    Vainshtein, Igor; Baruch, Shlomi; Regev, Itai; Segal, Victor; Filis, Avishai; Riabzev, Sergey

    2018-05-01

    The growing demand for EO applications that work around the clock 24hr/7days a week, such as in border surveillance systems, emphasizes the need for a highly reliable cryocooler having increased operational availability and optimized system's Integrated Logistic Support (ILS). In order to meet this need, RICOR developed linear and rotary cryocoolers which achieved successfully this goal. Cryocoolers MTTF was analyzed by theoretical reliability evaluation methods, demonstrated by normal and accelerated life tests at Cryocooler level and finally verified by field data analysis derived from Cryocoolers operating at system level. The following paper reviews theoretical reliability analysis methods together with analyzing reliability test results derived from standard and accelerated life demonstration tests performed at Ricor's advanced reliability laboratory. As a summary for the work process, reliability verification data will be presented as a feedback from fielded systems.

  13. Using archetypes to create user panels for usability studies: Streamlining focus groups and user studies.

    PubMed

    Stavrakos, S-K; Ahmed-Kristensen, S; Goldman, T

    2016-09-01

    Designers at the conceptual phase of products such as headphones, stress the importance of comfort, e.g. executing comfort studies and the need for a reliable user panel. This paper proposes a methodology to issue a reliable user panel to represent large populations and validates the proposed framework to predict comfort factors, such as physical fit. Data of 200 heads was analyzed by forming clusters, 9 archetypal people were identified out of a 200 people's ear database. The archetypes were validated by comparing the archetypes' responses on physical fit against those of 20 participants interacting with 6 headsets. This paper suggests a new method of selecting representative user samples for prototype testing compared to costly and time consuming methods which relied on the analysis of human geometry of large populations. Copyright © 2016 Elsevier Ltd. All rights reserved.

  14. Initial assessment of hearing loss using a mobile application for audiological evaluation.

    PubMed

    Derin, S; Cam, O H; Beydilli, H; Acar, E; Elicora, S S; Sahan, M

    2016-03-01

    This study aimed to compare an Apple iOS mobile operating system application for audiological evaluation with conventional audiometry, and to determine its accuracy and reliability in the initial evaluation of hearing loss. The study comprised 32 patients (16 females) diagnosed with hearing loss. The patients were first evaluated with conventional audiometry and the degree of hearing loss was recorded. Then they underwent a smartphone-based hearing test and the data were compared using Cohen's kappa analysis. Patients' mean age was 53.59 ± 18.01 years (range, 19-85 years). The mobile phone audiometry results for 39 of the 64 ears were fully compatible with the conventional audiometry results. There was a statistically significant concordant relationship between the two sets of audiometry results (p < 0.05). Ear Trumpet version 1.0.2 is a compact and simple mobile application on the Apple iPhone 5 that can measure hearing loss with reliable results.

  15. Autism detection in early childhood (ADEC): reliability and validity data for a Level 2 screening tool for autistic disorder.

    PubMed

    Nah, Yong-Hwee; Young, Robyn L; Brewer, Neil; Berlingeri, Genna

    2014-03-01

    The Autism Detection in Early Childhood (ADEC; Young, 2007) was developed as a Level 2 clinician-administered autistic disorder (AD) screening tool that was time-efficient, suitable for children under 3 years, easy to administer, and suitable for persons with minimal training and experience with AD. A best estimate clinical Diagnostic and Statistical Manual of Mental Disorders (4th ed., text rev.; DSM-IV-TR; American Psychiatric Association, 2000) diagnosis of AD was made for 70 children using all available information and assessment results, except for the ADEC data. A screening study compared these children on the ADEC with 57 children with other developmental disorders and 64 typically developing children. Results indicated high internal consistency (α = .91). Interrater reliability and test-retest reliability of the ADEC were also adequate. ADEC scores reliably discriminated different diagnostic groups after controlling for nonverbal IQ and Vineland Adaptive Behavior Composite scores. Construct validity (using exploratory factor analysis) and concurrent validity using performance on the Autism Diagnostic Observation Schedule (Lord et al., 2000), the Autism Diagnostic Interview-Revised (Le Couteur, Lord, & Rutter, 2003), and DSM-IV-TR criteria were also demonstrated. Signal detection analysis identified the optimal ADEC cutoff score, with the ADEC identifying all children who had an AD (N = 70, sensitivity = 1.0) but overincluding children with other disabilities (N = 13, specificity ranging from .74 to .90). Together, the reliability and validity data indicate that the ADEC has potential to be established as a suitable and efficient screening tool for infants with AD. 2014 APA

  16. Reliability of performance of elite Olympic weightlifters.

    PubMed

    McGuigan, Michael R; Kane, Melissa K

    2004-08-01

    There are no published data on the reliability of competitive strength performance, even though it has a pronounced effect on athletes' medal prospects and the ability of coaches and athletes to identify factors that affect competitive performance. The purpose of this investigation was to analyze the reliability of elite olympic weightlifters over a series of international weightlifting meets. We obtained official results of international competitions over an 18-month period from 1999 until the 2000 Olympic Games at the International Weightlifting Federation website. The measure of reliability was the typical within-athlete variation, derived as the coefficient of variation (CV) by 2-way analysis of variance of log-transformed weights lifted for the snatch, clean and jerk, and total. The results of this analysis were (a) within-athlete variations were as follows: snatch, 2.7% (95% likely range, 2.4-3.2%); clean and jerk, 2.3% (1.7-3.6%); total weight lifted, 2.5% (2.2-2.9%); (b) men and women: the variation was higher for the women compared with the men in both snatch (ratio of CV, 1.4) and clean and jerk (ratio of CV, 1.5), and for the total weight lifted (ratio of CV, 1.3); and (c) the top 5 athletes were almost always more reliable than the bottom-half athletes. Recent work has shown that the smallest worthwhile performance is about half the within-athlete variation, so coaches and sport scientists should focus on enhancements of as little as 1.2% in total weight lifted for elite olympic weightlifters.

  17. THE RELIABILITY AND CONCURRENT VALIDITY OF MEASUREMENTS USED TO QUANTIFY LUMBAR SPINE MOBILITY: AN ANALYSIS OF AN IPHONE® APPLICATION AND GRAVITY BASED INCLINOMETRY

    PubMed Central

    Pizzini, Matias; Robinson, Ashley; Yanez, Dania; Hanney, William J.

    2013-01-01

    Purpose/Aim: This purpose of this study was to investigate the reliability, minimal detectable change (MDC), and concurrent validity of active spinal mobility measurements using a gravity‐based bubble inclinometer and iPhone® application. Materials/Methods: Two investigators each used a bubble inclinometer and an iPhone® with inclinometer application to measure total thoracolumbo‐pelvic flexion, isolated lumbar flexion, total thoracolumbo‐pelvic extension, and thoracolumbar lateral flexion in 30 asymptomatic participants using a blinded repeated measures design. Results: The procedures used in this investigation for measuring spinal mobility yielded good intrarater and interrater reliability with Intraclass Correlation Coefficients (ICC) for bubble inclinometry ≥ 0.81 and the iPhone® ≥ 0.80. The MDC90 for the interrater analysis ranged from 4° to 9°. The concurrent validity between bubble inclinometry and the iPhone® application was good with ICC values of ≥ 0.86. The 95% level of agreement indicates that although these measuring instruments are equivalent individual differences of up to 18° may exist when using these devices interchangeably. Conclusions: The bubble inclinometer and iPhone® possess good intrarater and interrater reliability as well as concurrent validity when strict measurement procedures are adhered to. This study provides preliminary evidence to suggest that smart phone applications may offer clinical utility comparable to inclinometry for quantifying spinal mobility. Clinicians should be aware of the potential disagreement when using these devices interchangeably. Level of Evidence: 2b (Observational study of reliability) PMID:23593551

  18. The reliability and concurrent validity of measurements used to quantify lumbar spine mobility: an analysis of an iphone® application and gravity based inclinometry.

    PubMed

    Kolber, Morey J; Pizzini, Matias; Robinson, Ashley; Yanez, Dania; Hanney, William J

    2013-04-01

    PURPOSEAIM: This purpose of this study was to investigate the reliability, minimal detectable change (MDC), and concurrent validity of active spinal mobility measurements using a gravity-based bubble inclinometer and iPhone® application. MATERIALSMETHODS: Two investigators each used a bubble inclinometer and an iPhone® with inclinometer application to measure total thoracolumbo-pelvic flexion, isolated lumbar flexion, total thoracolumbo-pelvic extension, and thoracolumbar lateral flexion in 30 asymptomatic participants using a blinded repeated measures design. The procedures used in this investigation for measuring spinal mobility yielded good intrarater and interrater reliability with Intraclass Correlation Coefficients (ICC) for bubble inclinometry ≥ 0.81 and the iPhone® ≥ 0.80. The MDC90 for the interrater analysis ranged from 4° to 9°. The concurrent validity between bubble inclinometry and the iPhone® application was good with ICC values of ≥ 0.86. The 95% level of agreement indicates that although these measuring instruments are equivalent individual differences of up to 18° may exist when using these devices interchangeably. The bubble inclinometer and iPhone® possess good intrarater and interrater reliability as well as concurrent validity when strict measurement procedures are adhered to. This study provides preliminary evidence to suggest that smart phone applications may offer clinical utility comparable to inclinometry for quantifying spinal mobility. Clinicians should be aware of the potential disagreement when using these devices interchangeably. 2b (Observational study of reliability).

  19. Soft error evaluation and vulnerability analysis in Xilinx Zynq-7010 system-on chip

    NASA Astrophysics Data System (ADS)

    Du, Xuecheng; He, Chaohui; Liu, Shuhuan; Zhang, Yao; Li, Yonghong; Xiong, Ceng; Tan, Pengkang

    2016-09-01

    Radiation-induced soft errors are an increasingly important threat to the reliability of modern electronic systems. In order to evaluate system-on chip's reliability and soft error, the fault tree analysis method was used in this work. The system fault tree was constructed based on Xilinx Zynq-7010 All Programmable SoC. Moreover, the soft error rates of different components in Zynq-7010 SoC were tested by americium-241 alpha radiation source. Furthermore, some parameters that used to evaluate the system's reliability and safety were calculated using Isograph Reliability Workbench 11.0, such as failure rate, unavailability and mean time to failure (MTTF). According to fault tree analysis for system-on chip, the critical blocks and system reliability were evaluated through the qualitative and quantitative analysis.

  20. Weighted Fuzzy Risk Priority Number Evaluation of Turbine and Compressor Blades Considering Failure Mode Correlations

    NASA Astrophysics Data System (ADS)

    Gan, Luping; Li, Yan-Feng; Zhu, Shun-Peng; Yang, Yuan-Jian; Huang, Hong-Zhong

    2014-06-01

    Failure mode, effects and criticality analysis (FMECA) and Fault tree analysis (FTA) are powerful tools to evaluate reliability of systems. Although single failure mode issue can be efficiently addressed by traditional FMECA, multiple failure modes and component correlations in complex systems cannot be effectively evaluated. In addition, correlated variables and parameters are often assumed to be precisely known in quantitative analysis. In fact, due to the lack of information, epistemic uncertainty commonly exists in engineering design. To solve these problems, the advantages of FMECA, FTA, fuzzy theory, and Copula theory are integrated into a unified hybrid method called fuzzy probability weighted geometric mean (FPWGM) risk priority number (RPN) method. The epistemic uncertainty of risk variables and parameters are characterized by fuzzy number to obtain fuzzy weighted geometric mean (FWGM) RPN for single failure mode. Multiple failure modes are connected using minimum cut sets (MCS), and Boolean logic is used to combine fuzzy risk priority number (FRPN) of each MCS. Moreover, Copula theory is applied to analyze the correlation of multiple failure modes in order to derive the failure probabilities of each MCS. Compared to the case where dependency among multiple failure modes is not considered, the Copula modeling approach eliminates the error of reliability analysis. Furthermore, for purpose of quantitative analysis, probabilities importance weight from failure probabilities are assigned to FWGM RPN to reassess the risk priority, which generalize the definition of probability weight and FRPN, resulting in a more accurate estimation than that of the traditional models. Finally, a basic fatigue analysis case drawn from turbine and compressor blades in aeroengine is used to demonstrate the effectiveness and robustness of the presented method. The result provides some important insights on fatigue reliability analysis and risk priority assessment of structural system under failure correlations.

  1. Reliability Estimation for Single-unit Ceramic Crown Restorations

    PubMed Central

    Lekesiz, H.

    2014-01-01

    The objective of this study was to evaluate the potential of a survival prediction method for the assessment of ceramic dental restorations. For this purpose, fast-fracture and fatigue reliabilities for 2 bilayer (metal ceramic alloy core veneered with fluorapatite leucite glass-ceramic, d.Sign/d.Sign-67, by Ivoclar; glass-infiltrated alumina core veneered with feldspathic porcelain, VM7/In-Ceram Alumina, by Vita) and 3 monolithic (leucite-reinforced glass-ceramic, Empress, and ProCAD, by Ivoclar; lithium-disilicate glass-ceramic, Empress 2, by Ivoclar) single posterior crown restorations were predicted, and fatigue predictions were compared with the long-term clinical data presented in the literature. Both perfectly bonded and completely debonded cases were analyzed for evaluation of the influence of the adhesive/restoration bonding quality on estimations. Material constants and stress distributions required for predictions were calculated from biaxial tests and finite element analysis, respectively. Based on the predictions, In-Ceram Alumina presents the best fast-fracture resistance, and ProCAD presents a comparable resistance for perfect bonding; however, ProCAD shows a significant reduction of resistance in case of complete debonding. Nevertheless, it is still better than Empress and comparable with Empress 2. In-Ceram Alumina and d.Sign have the highest long-term reliability, with almost 100% survivability even after 10 years. When compared with clinical failure rates reported in the literature, predictions show a promising match with clinical data, and this indicates the soundness of the settings used in the proposed predictions. PMID:25048249

  2. Short Assessment of Health Literacy—Spanish and English: A Comparable Test of Health Literacy for Spanish and English Speakers

    PubMed Central

    Lee, Shoou-Yih Daniel; Stucky, Brian D; Lee, Jessica Y; Rozier, R Gary; Bender, Deborah E

    2010-01-01

    Objective The intent of the study was to develop and validate a comparable health literacy test for Spanish-speaking and English-speaking populations. Study Design The design of the instrument, named the Short Assessment of Health Literacy—Spanish and English (SAHL-S&E), combined a word recognition test, as appearing in the Rapid Estimate of Adult Literacy in Medicine (REALM), and a comprehension test using multiple-choice questions designed by an expert panel. We used the item response theory (IRT) in developing and validating the instrument. Data Collection Validation of SAHL-S&E involved testing and comparing the instrument with other health literacy instruments in a sample of 201 Spanish-speaking and 202 English-speaking subjects recruited from the Ambulatory Care Center at the University of North Carolina Healthcare System. Principal Findings Based on IRT analysis, 18 items were retained in the comparable test. The Spanish version of the test, SAHL-S, was highly correlated with other Spanish health literacy instruments, Short Assessment of Health Literacy for Spanish-Speaking Adults (r=0.88, p<.05) and the Spanish Test of Functional Health Literacy in Adults (TOFHLA) (r=0.62, p<.05). The English version, SAHL-E, had high correlations with REALM (r=0.94, p<.05) and the English TOFHLA (r=0.68, p<.05). Significant correlations were found between SAHL-S&E and years of schooling in both Spanish- and English-speaking samples (r=0.15 and 0.39, respectively). SAHL-S&E displayed satisfactory reliability of 0.80 and 0.89 in the Spanish- and English-speaking samples, respectively. IRT analysis indicated that the SAHL-S&E score was highly reliable for individuals with a low level of health literacy. Conclusions The new instrument, SAHL-S&E, has good reliability and validity. It is particularly useful for identifying individuals with low health literacy and could be used to screen for low health literacy among Spanish and English speakers. PMID:20500222

  3. Extended performance electric propulsion power processor design study. Volume 2: Technical summary

    NASA Technical Reports Server (NTRS)

    Biess, J. J.; Inouye, L. Y.; Schoenfeld, A. D.

    1977-01-01

    Electric propulsion power processor technology has processed during the past decade to the point that it is considered ready for application. Several power processor design concepts were evaluated and compared. Emphasis was placed on a 30 cm ion thruster power processor with a beam power rating supply of 2.2KW to 10KW for the main propulsion power stage. Extension in power processor performance were defined and were designed in sufficient detail to determine efficiency, component weight, part count, reliability and thermal control. A detail design was performed on a microprocessor as the thyristor power processor controller. A reliability analysis was performed to evaluate the effect of the control electronics redesign. Preliminary electrical design, mechanical design and thermal analysis were performed on a 6KW power transformer for the beam supply. Bi-Mod mechanical, structural and thermal control configurations were evaluated for the power processor and preliminary estimates of mechanical weight were determined.

  4. Recoding low-level simulator data into a record of meaningful task performance: the integrated task modeling environment (ITME).

    PubMed

    King, Robert; Parker, Simon; Mouzakis, Kon; Fletcher, Winston; Fitzgerald, Patrick

    2007-11-01

    The Integrated Task Modeling Environment (ITME) is a user-friendly software tool that has been developed to automatically recode low-level data into an empirical record of meaningful task performance. The present research investigated and validated the performance of the ITME software package by conducting complex simulation missions and comparing the task analyses produced by ITME with taskanalyses produced by experienced video analysts. A very high interrater reliability (> or = .94) existed between experienced video analysts and the ITME for the task analyses produced for each mission. The mean session time:analysis time ratio was 1:24 using video analysis techniques and 1:5 using the ITME. It was concluded that the ITME produced task analyses that were as reliable as those produced by experienced video analysts, and significantly reduced the time cost associated with these analyses.

  5. Surgical swab counting: a qualitative analysis from the perspective of the scrub nurse.

    PubMed

    D'Lima, D; Sacks, M; Blackman, W; Benn, J

    2014-05-01

    The aim of the study was to conduct a qualitative exploration of the sociotechnical processes underlying retained surgical swabs, and to explore the fundamental reasons why the swab count procedure and related protocols fail in practice. Data was collected through a set of 27 semistructured qualitative interviews with scrub nurses from a large, multi-site teaching hospital. Interview transcripts were analysed using established constant comparative methods, moving between inductive and deductive reasoning. Key findings were associated with interprofessional perspectives, team processes and climate and responsibility for the swab count. The analysis of risk factors revealed that perceived social and interprofessional issues played a significant role in the reliability of measures to prevent retained swabs. This work highlights the human, psychological and organisational factors that impact upon the reliability of the process and gives rise to recommendations to address contextual factors and improve perioperative practice and training.

  6. Measuring psychosocial exposures: validation of the Persian of the copenhagen psychosocial questionnaire (COPSOQ)

    PubMed Central

    Pournik, Omid; Ghalichi, Leila; TehraniYazdi, Alireza; Tabatabaee, Seyed Mohammad; Ghaffari, Mostafa; Vingard, Eva

    2015-01-01

    Background: The effect of psychosocial work environment on personal and organizational aspects of employees is well-known; and it is of fundamental importance to have valid tools to evaluate them. This study aims to evaluate the reliability and validity of the Persian version of Copenhagen Psychosocial Questionnaire (COPSOQ). Methods: The questionnaire was translated into Persian and then back translated into English by two translators separately. The wording of the final Persian version was established by comparing the translated versions with the original questionnaire. One hundred three health care workers completed the questionnaire. Chronbach’s alpha was calculated, and factor analysis was performed. Results: Factor analysis revealed acceptable validity for the five contexts of the questionnaire. Cronbach’s alpha ranged from 0.73 to 0.82 in different contexts. Conclusion: This study revealed that the Persian version of COPSOQ is a reliable and valid instrument for measuring psychosocial factors at work. PMID:26478879

  7. Developing a postal screening tool for frailty in primary care: a secondary data analysis.

    PubMed

    Kydd, Lauren

    2016-07-01

    The purpose of this secondary data analysis (SDA) was to review a subset of quantitative and qualitative paired data sets from a returned postal screening tool (PST) completed by patients and compare them to the clinical letters composed by elderly care community nurses (ECCN) following patient assessment to ascertain the tool's reliability and validity. The aim was to understand to what extent the problems identified by patients in PSTs aligned with actual or potential problems identified by the ECCNs. The researcher examined this connection to establish whether the PST was a valid, reliable approach to proactive care. The findings of this SDA indicated that patients did understand the PST. Many appropriate referrals were made as a result of the ECCN visit that would not have occurred if the PST had not been sent. This article focuses specifically upon the physiotherapy section as this was the area where the most red flags were identified.

  8. Qualitative Importance Measures of Systems Components - A New Approach and Its Applications

    NASA Astrophysics Data System (ADS)

    Chybowski, Leszek; Gawdzińska, Katarzyna; Wiśnicki, Bogusz

    2016-12-01

    The paper presents an improved methodology of analysing the qualitative importance of components in the functional and reliability structures of the system. We present basic importance measures, i.e. the Birnbaum's structural measure, the order of the smallest minimal cut-set, the repetition count of an i-th event in the Fault Tree and the streams measure. A subsystem of circulation pumps and fuel heaters in the main engine fuel supply system of a container vessel illustrates the qualitative importance analysis. We constructed a functional model and a Fault Tree which we analysed using qualitative measures. Additionally, we compared the calculated measures and introduced corrected measures as a tool for improving the analysis. We proposed scaled measures and a common measure taking into account the location of the component in the reliability and functional structures. Finally, we proposed an area where the measures could be applied.

  9. Cross-validating a bidimensional mathematics anxiety scale.

    PubMed

    Haiyan Bai

    2011-03-01

    The psychometric properties of a 14-item bidimensional Mathematics Anxiety Scale-Revised (MAS-R) were empirically cross-validated with two independent samples consisting of 647 secondary school students. An exploratory factor analysis on the scale yielded strong construct validity with a clear two-factor structure. The results from a confirmatory factor analysis indicated an excellent model-fit (χ(2) = 98.32, df = 62; normed fit index = .92, comparative fit index = .97; root mean square error of approximation = .04). The internal consistency (.85), test-retest reliability (.71), interfactor correlation (.26, p < .001), and positive discrimination power indicated that MAS-R is a psychometrically reliable and valid instrument for measuring mathematics anxiety. Math anxiety, as measured by MAS-R, correlated negatively with student achievement scores (r = -.38), suggesting that MAS-R may be a useful tool for classroom teachers and other educational personnel tasked with identifying students at risk of reduced math achievement because of anxiety.

  10. TWO MEASURES FOR CROSS-CULTURAL RESEARCH ON MORALITY: COMPARISON AND REVISION.

    PubMed

    Zhang, Yanyan; Li, Sisi

    2015-08-01

    The current research assessed the reliability and validity of two Western measures of morality in a Chinese sample, namely the Community, Autonomy, and Divinity Scale (CADS) and the Moral Foundations Questionnaire (MFQ). Questionnaires were administered to 274 Chinese participants in Northern China (M age = 25.4 yr., SD = 8.50; 86% women). Confirmatory factor analysis using a structural equation model was conducted to evaluate the construct validity of the two scales. The results indicated a reasonable model fit of both the CADS and the MFQ after certain modifications. The revised versions of both measures had good internal consistency reliabilities. Correlation analysis indicated moderate correlations between the dimensions of the two scales. Regarding the content of morality, Chinese people endorsed more of the traditional ethics and foundations than people from Western cultures in other studies. In addition, participants who reported a religious affiliation scored higher on the Divinity subscale compared to those who claimed to be atheists.

  11. [Eppendorf Schizophrenia Inventory (ESI) vs. Frankfurt Complaint Questionnaire (FCQ). Direct comparison in a clinical trial].

    PubMed

    Mass, R

    2005-09-01

    This study is the first to directly compare two clinical questionnaires which are both aimed at self-experienced cognitive dysfunctions of schizophrenia: Eppendorf Schizophrenia Inventory (ESI) and Frankfurt Complaint Questionnaire (FCQ). Evaluated were (a) diagnostic validity, (b) psychometric properties, (c) scale intercorrelations, and (d) factor analytic stability. Ad (a): schizophrenic subjects (n=36) show highly significant increases in the ESI scales and sum score when compared to other clinical groups (patients with depression, alcohol dependence, or obsessive-compulsive disorder, n>30, respectively); on the other hand, the FCQ yields no systematic group differences. Ad (b): mean of reliability coefficients (Cronbach alpha) of the ESI scales is r(tt)=0.86, mean of reliability coefficients of the FCQ scales is significantly lower. Ad (c): the mean intercorrelation between ESI and FCQ scales amounts to r(xy)=0.56 (minimum 0.29, maximum 0.73), corresponding to an average shared variance of about 31%. Ad (d): factor analysis yielded an ESI factor and a FBF factor; one-way ANOVA with the factor scores confirms the diagnostic validity of the ESI. ESI and FCQ measure essentially different aspects of schizophrenic psychopathology. Regarding reliability and diagnostic validity, the ESI is superior to the FCQ.

  12. Influence of speech sample on perceptual rating of hypernasality.

    PubMed

    Medeiros, Maria Natália Leite de; Fukushiro, Ana Paula; Yamashita, Renata Paciello

    2016-07-07

    To investigate the influence of speech sample of spontaneous conversation or sentences repetition on intra and inter-rater hypernasality reliability. One hundred and twenty audio recorded speech samples (60 containing spontaneous conversation and 60 containing repeated sentences) of individuals with repaired cleft palate±lip, both genders, aged between 6 and 52 years old (mean=21±10) were selected and edited. Three experienced speech and language pathologists rated hypernasality according to their own criteria using 4-point scale: 1=absence of hypernasality, 2=mild hypernasality, 3=moderate hypernasality and 4=severe hypernasality, first in spontaneous speech samples and 30 days after, in sentences repetition samples. Intra- and inter-rater agreements were calculated for both speech samples and were statistically compared by the Z test at a significance level of 5%. Comparison of intra-rater agreements between both speech samples showed an increase of the coefficients obtained in the analysis of sentences repetition compared to those obtained in spontaneous conversation. Comparison between inter-rater agreement showed no significant difference among the three raters for the two speech samples. Sentences repetition improved intra-raters reliability of perceptual judgment of hypernasality. However, the speech sample had no influence on reliability among different raters.

  13. Validation of a computerized algorithm to quantify fetal heart rate deceleration area.

    PubMed

    Gyllencreutz, Erika; Lu, Ke; Lindecrantz, Kaj; Lindqvist, Pelle G; Nordstrom, Lennart; Holzmann, Malin; Abtahi, Farhad

    2018-05-16

    Reliability in visual cardiotocography interpretation is unsatisfying, which has led to development of computerized cardiotocography. Computerized analysis is well established for antenatal fetal surveillance, but has yet not performed sufficiently during labor. We aimed to investigate the capacity of a new computerized algorithm compared to visual assessment in identifying intrapartum fetal heart rate baseline and decelerations. Three-hundred-and-twelve intrapartum cardiotocography tracings with variable decelerations were analysed by the computerized algorithm and visually examined by two observers, blinded to each other and the computer analysis. The width, depth and area of each deceleration was measured. Four cases (>100 variable decelerations) were subject to in-depth detailed analysis. The outcome measures were bias in seconds (width), beats per minute (depth), and beats (area) between computer and observers by using Bland-Altman analysis. Interobserver reliability was determined by calculating intraclass correlation and Spearman rank analysis. The analysis (312 cases) showed excellent intraclass correlation (0.89-0.95) and very strong Spearman correlation (0.82-0.91). The detailed analysis of > 100 decelerations in 4 cases revealed low bias between the computer and the two observers; width 1.4 and 1.4 seconds, depth 5.1 and 0.7 beats per minute, and area 0.1 and -1.7 beats. This was comparable to the bias between the two observers; 0.3 seconds (width), 4.4 beats per minute (depth), and 1.7 beats (area). The intraclass correlation was excellent (0.90-0.98). A novel computerized algorithm for intrapartum cardiotocography analysis is as accurate as gold standard visual assessment with high correlation and low bias. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  14. The Influence of Study-Level Inference Models and Study Set Size on Coordinate-Based fMRI Meta-Analyses

    PubMed Central

    Bossier, Han; Seurinck, Ruth; Kühn, Simone; Banaschewski, Tobias; Barker, Gareth J.; Bokde, Arun L. W.; Martinot, Jean-Luc; Lemaitre, Herve; Paus, Tomáš; Millenet, Sabina; Moerkerke, Beatrijs

    2018-01-01

    Given the increasing amount of neuroimaging studies, there is a growing need to summarize published results. Coordinate-based meta-analyses use the locations of statistically significant local maxima with possibly the associated effect sizes to aggregate studies. In this paper, we investigate the influence of key characteristics of a coordinate-based meta-analysis on (1) the balance between false and true positives and (2) the activation reliability of the outcome from a coordinate-based meta-analysis. More particularly, we consider the influence of the chosen group level model at the study level [fixed effects, ordinary least squares (OLS), or mixed effects models], the type of coordinate-based meta-analysis [Activation Likelihood Estimation (ALE) that only uses peak locations, fixed effects, and random effects meta-analysis that take into account both peak location and height] and the amount of studies included in the analysis (from 10 to 35). To do this, we apply a resampling scheme on a large dataset (N = 1,400) to create a test condition and compare this with an independent evaluation condition. The test condition corresponds to subsampling participants into studies and combine these using meta-analyses. The evaluation condition corresponds to a high-powered group analysis. We observe the best performance when using mixed effects models in individual studies combined with a random effects meta-analysis. Moreover the performance increases with the number of studies included in the meta-analysis. When peak height is not taken into consideration, we show that the popular ALE procedure is a good alternative in terms of the balance between type I and II errors. However, it requires more studies compared to other procedures in terms of activation reliability. Finally, we discuss the differences, interpretations, and limitations of our results. PMID:29403344

  15. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wilson, E.; Engebrecht-Metzger, C.; Horowitz, S.

    As BA has grown to include a large and diverse cross-section of the home building and retrofit industries, it has become more important to develop accurate, consistent analysis techniques to measure progress towards the program's goals. The House Simulation Protocol (HSP) document provides guidance to program partners and managers so they can compare energy savings for new construction and retrofit projects. The HSP provides the program with analysis methods that are proven to be effective and reliable in investigating the energy use of advanced energy systems and of entire houses.

  16. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wilson, E.; Engebrecht, C. Metzger; Horowitz, S.

    As Building America has grown to include a large and diverse cross-section of the home building and retrofit industries, it has become more important to develop accurate, consistent analysis techniques to measure progress towards the program's goals. The House Simulation Protocol (HSP) document provides guidance to program partners and managers so they can compare energy savings for new construction and retrofit projects. The HSP provides the program with analysis methods that are proven to be effective and reliable in investigating the energy use of advanced energy systems and of entire houses.

  17. Validation of Shielding Analysis Capability of SuperMC with SINBAD

    NASA Astrophysics Data System (ADS)

    Chen, Chaobin; Yang, Qi; Wu, Bin; Han, Yuncheng; Song, Jing

    2017-09-01

    Abstract: The shielding analysis capability of SuperMC was validated with the Shielding Integral Benchmark Archive Database (SINBAD). The SINBAD was compiled by RSICC and NEA, it includes numerous benchmark experiments performed with the D-T fusion neutron source facilities of OKTAVIAN, FNS, IPPE, etc. The results from SuperMC simulation were compared with experimental data and MCNP results. Very good agreement with deviation lower than 1% was achieved and it suggests that SuperMC is reliable in shielding calculation.

  18. Human Reliability Analysis in Support of Risk Assessment for Positive Train Control

    DOT National Transportation Integrated Search

    2003-06-01

    This report describes an approach to evaluating the reliability of human actions that are modeled in a probabilistic risk assessment : (PRA) of train control operations. This approach to human reliability analysis (HRA) has been applied in the case o...

  19. Software reliability models for fault-tolerant avionics computers and related topics

    NASA Technical Reports Server (NTRS)

    Miller, Douglas R.

    1987-01-01

    Software reliability research is briefly described. General research topics are reliability growth models, quality of software reliability prediction, the complete monotonicity property of reliability growth, conceptual modelling of software failure behavior, assurance of ultrahigh reliability, and analysis techniques for fault-tolerant systems.

  20. Development of a probabilistic analysis methodology for structural reliability estimation

    NASA Technical Reports Server (NTRS)

    Torng, T. Y.; Wu, Y.-T.

    1991-01-01

    The novel probabilistic analysis method for assessment of structural reliability presented, which combines fast-convolution with an efficient structural reliability analysis, can after identifying the most important point of a limit state proceed to establish a quadratic-performance function. It then transforms the quadratic function into a linear one, and applies fast convolution. The method is applicable to problems requiring computer-intensive structural analysis. Five illustrative examples of the method's application are given.

  1. Error Propagation Analysis in the SAE Architecture Analysis and Design Language (AADL) and the EDICT Tool Framework

    NASA Technical Reports Server (NTRS)

    LaValley, Brian W.; Little, Phillip D.; Walter, Chris J.

    2011-01-01

    This report documents the capabilities of the EDICT tools for error modeling and error propagation analysis when operating with models defined in the Architecture Analysis & Design Language (AADL). We discuss our experience using the EDICT error analysis capabilities on a model of the Scalable Processor-Independent Design for Enhanced Reliability (SPIDER) architecture that uses the Reliable Optical Bus (ROBUS). Based on these experiences we draw some initial conclusions about model based design techniques for error modeling and analysis of highly reliable computing architectures.

  2. Educational testing validity and reliability in pharmacy and medical education literature.

    PubMed

    Hoover, Matthew J; Jung, Rose; Jacobs, David M; Peeters, Michael J

    2013-12-16

    To evaluate and compare the reliability and validity of educational testing reported in pharmacy education journals to medical education literature. Descriptions of validity evidence sources (content, construct, criterion, and reliability) were extracted from articles that reported educational testing of learners' knowledge, skills, and/or abilities. Using educational testing, the findings of 108 pharmacy education articles were compared to the findings of 198 medical education articles. For pharmacy educational testing, 14 articles (13%) reported more than 1 validity evidence source while 83 articles (77%) reported 1 validity evidence source and 11 articles (10%) did not have evidence. Among validity evidence sources, content validity was reported most frequently. Compared with pharmacy education literature, more medical education articles reported both validity and reliability (59%; p<0.001). While there were more scholarship of teaching and learning (SoTL) articles in pharmacy education compared to medical education, validity, and reliability reporting were limited in the pharmacy education literature.

  3. Subtyping adolescents with bulimia nervosa.

    PubMed

    Chen, Eunice Y; Le Grange, Daniel

    2007-12-01

    Cluster analyses of eating disorder patients have yielded a "dietary-depressive" subtype, typified by greater negative affect, and a "dietary" subtype, typified by dietary restraint. This study aimed to replicate these findings in an adolescent sample with bulimia nervosa (BN) from a randomized controlled trial and to examine the validity and reliability of this methodology. In the sample of BN adolescents (N=80), cluster analysis revealed a "dietary-depressive" subtype (37.5%) and a "dietary" subtype (62.5%) using the Beck Depression Inventory, Rosenberg Self-Esteem Scale and Eating Disorder Examination Restraint subscale. The "dietary-depressive" subtype compared to the "dietary" subtype was significantly more likely to: (1) report co-occurring disorders, (2) greater eating and weight concerns, and (3) less vomiting abstinence at post-treatment (all p's<.05). The cluster analysis based on "dietary" and "dietary-depressive" subtypes appeared to have concurrent validity, yielding more distinct groups than subtyping by vomiting frequency. In order to assess the reliability of the subtyping scheme, a larger sample of adolescents with mixed eating and weight disorders in an outpatient eating disorder clinic (N=149) was subtyped, yielding similar subtypes. These results support the validity and reliability of the subtyping strategy in two adolescent samples.

  4. Reliability and Validity Study of a Tool to Measure Cancer Stigma: Patient Version.

    PubMed

    Yılmaz, Medine; Dişsiz, Gülçin; Demir, Filiz; Irız, Sibel; Alacacioglu, Ahmet

    2017-01-01

    The aim of this methodological study is to establish the validity and reliability of the Turkish version of "A Questionnaire for Measuring Attitudes toward Cancer (Cancer Stigma) - Patient version." The sample comprised oncology patients who had active cancer treatment. The construct validity was assessed using the confirmatory and exploratory factor analysis. The mean age of the participants was 54.9±12.3 years. In the confirmatory factor analysis, fit values were determined as comparative fit index = 0.93, goodness of fit index = 0.91, normed-fit index=0.91, and root mean square error of approximation RMSEA = 0.09 ( P <0.05) (Kaiser-Meyer-Olkin = 0.88, χ 2 = 1084.41, Df = 66, and Barletta's test P <0.000). The first factor was "impossibility of recovery and experience of social discrimination" and the second factor was "stereotypes of cancer patients." The two-factor structure accounted for 56.74% of the variance. The Cronbach's alpha value was determined as 0.88 for the two-factor scale. "A questionnaire for measuring attitudes toward cancer (cancer stigma) - Patient version" is a reliable and valid questionnaire to assess stigmatization of cancer in cancer patients.

  5. A new criterion to evaluate water vapor interference in protein secondary structural analysis by FTIR spectroscopy.

    PubMed

    Zou, Ye; Ma, Gang

    2014-06-04

    Second derivative and Fourier self-deconvolution (FSD) are two commonly used techniques to resolve the overlapped component peaks from the often featureless amide I band in Fourier transform infrared (FTIR) curve-fitting approach for protein secondary structural analysis. Yet, the reliability of these two techniques is greatly affected by the omnipresent water vapor in the atmosphere. Several criteria are currently in use as quality controls to ensure the protein absorption spectrum is negligibly affected by water vapor interference. In this study, through a second derivative study of liquid water, we first argue that the previously established criteria cannot guarantee a reliable evaluation of water vapor interference due to a phenomenon that we refer to as sample's absorbance-dependent water vapor interference. Then, through a comparative study of protein and liquid water, we show that a protein absorption spectrum can still be significantly affected by water vapor interference even though it satisfies the established criteria. At last, we propose to use the comparison between the second derivative spectra of protein and liquid water as a new criterion to better evaluate water vapor interference for more reliable second derivative and FSD treatments on the protein amide I band.

  6. Impact of distributed power electronics on the lifetime and reliability of PV systems: Impact of distributed power electronics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Olalla, Carlos; Maksimovic, Dragan; Deline, Chris

    Here, this paper quantifies the impact of distributed power electronics in photovoltaic (PV) systems in terms of end-of-life energy-capture performance and reliability. The analysis is based on simulations of PV installations over system lifetime at various degradation rates. It is shown how module-level or submodule-level power converters can mitigate variations in cell degradation over time, effectively increasing the system lifespan by 5-10 years compared with the nominal 25-year lifetime. An important aspect typically overlooked when characterizing such improvements is the reliability of distributed power electronics, as power converter failures may not only diminish energy yield improvements but also adversely affectmore » the overall system operation. Failure models are developed, and power electronics reliability is taken into account in this work, in order to provide a more comprehensive view of the opportunities and limitations offered by distributed power electronics in PV systems. Lastly, it is shown how a differential power-processing approach achieves the best mismatch mitigation performance and the least susceptibility to converter faults.« less

  7. Reliability and Validity of the Short Falls Efficacy Scale International in English, Mandarin, and Bahasa Malaysia in Malaysia.

    PubMed

    Tan, Maw Pin; Nalathamby, Nemala; Mat, Sumaiyah; Tan, Pey June; Kamaruzzaman, Shahrul Bahyah; Morgan, Karen

    2018-01-01

    While the prevalence of falls among Malaysian older adults is comparable to other older populations around the world, little is currently known about fear of falling in Malaysia. The Falls Efficacy Scale International (FES-I) and short FES-I scales to measure fear of falling have not yet been validated for use within the Malaysian population, and are currently not available in Bahasa Malaysia (BM). A total of 402 participants aged ≥63 years were recruited. The questionnaire was readministered to 149 participants, 4 to 8 weeks after the first administration to determine test-retest reliability. The original version of the 7-item short FES-I is available in English, while the Mandarin was adapted from the 16-item Mandarin FES-I. The BM version was translated according to protocol by four experts. The internal structure of the FES-I was examined by factor analysis. The 7-item short FES-I showed good internal reliability and test-retest reliability for English, Mandarin, and BM versions for Malaysia.

  8. Impact of distributed power electronics on the lifetime and reliability of PV systems: Impact of distributed power electronics

    DOE PAGES

    Olalla, Carlos; Maksimovic, Dragan; Deline, Chris; ...

    2017-04-26

    Here, this paper quantifies the impact of distributed power electronics in photovoltaic (PV) systems in terms of end-of-life energy-capture performance and reliability. The analysis is based on simulations of PV installations over system lifetime at various degradation rates. It is shown how module-level or submodule-level power converters can mitigate variations in cell degradation over time, effectively increasing the system lifespan by 5-10 years compared with the nominal 25-year lifetime. An important aspect typically overlooked when characterizing such improvements is the reliability of distributed power electronics, as power converter failures may not only diminish energy yield improvements but also adversely affectmore » the overall system operation. Failure models are developed, and power electronics reliability is taken into account in this work, in order to provide a more comprehensive view of the opportunities and limitations offered by distributed power electronics in PV systems. Lastly, it is shown how a differential power-processing approach achieves the best mismatch mitigation performance and the least susceptibility to converter faults.« less

  9. Reliability Analysis and Optimal Release Problem Considering Maintenance Time of Software Components for an Embedded OSS Porting Phase

    NASA Astrophysics Data System (ADS)

    Tamura, Yoshinobu; Yamada, Shigeru

    OSS (open source software) systems which serve as key components of critical infrastructures in our social life are still ever-expanding now. Especially, embedded OSS systems have been gaining a lot of attention in the embedded system area, i.e., Android, BusyBox, TRON, etc. However, the poor handling of quality problem and customer support prohibit the progress of embedded OSS. Also, it is difficult for developers to assess the reliability and portability of embedded OSS on a single-board computer. In this paper, we propose a method of software reliability assessment based on flexible hazard rates for the embedded OSS. Also, we analyze actual data of software failure-occurrence time-intervals to show numerical examples of software reliability assessment for the embedded OSS. Moreover, we compare the proposed hazard rate model for the embedded OSS with the typical conventional hazard rate models by using the comparison criteria of goodness-of-fit. Furthermore, we discuss the optimal software release problem for the porting-phase based on the total expected software maintenance cost.

  10. Risk-based maintenance of ethylene oxide production facilities.

    PubMed

    Khan, Faisal I; Haddara, Mahmoud R

    2004-05-20

    This paper discusses a methodology for the design of an optimum inspection and maintenance program. The methodology, called risk-based maintenance (RBM) is based on integrating a reliability approach and a risk assessment strategy to obtain an optimum maintenance schedule. First, the likely equipment failure scenarios are formulated. Out of many likely failure scenarios, the ones, which are most probable, are subjected to a detailed study. Detailed consequence analysis is done for the selected scenarios. Subsequently, these failure scenarios are subjected to a fault tree analysis to determine their probabilities. Finally, risk is computed by combining the results of the consequence and the probability analyses. The calculated risk is compared against known acceptable criteria. The frequencies of the maintenance tasks are obtained by minimizing the estimated risk. A case study involving an ethylene oxide production facility is presented. Out of the five most hazardous units considered, the pipeline used for the transportation of the ethylene is found to have the highest risk. Using available failure data and a lognormal reliability distribution function human health risk factors are calculated. Both societal risk factors and individual risk factors exceeded the acceptable risk criteria. To determine an optimal maintenance interval, a reverse fault tree analysis was used. The maintenance interval was determined such that the original high risk is brought down to an acceptable level. A sensitivity analysis is also undertaken to study the impact of changing the distribution of the reliability model as well as the error in the distribution parameters on the maintenance interval.

  11. Methodological issues in volumetric magnetic resonance imaging of the brain in the Edinburgh High Risk Project.

    PubMed

    Whalley, H C; Kestelman, J N; Rimmington, J E; Kelso, A; Abukmeil, S S; Best, J J; Johnstone, E C; Lawrie, S M

    1999-07-30

    The Edinburgh High Risk Project is a longitudinal study of brain structure (and function) in subjects at high risk of developing schizophrenia in the next 5-10 years for genetic reasons. In this article we describe the methods of volumetric analysis of structural magnetic resonance images used in the study. We also consider potential sources of error in these methods: the validity of our image analysis techniques; inter- and intra-rater reliability; possible positional variation; and thresholding criteria used in separating brain from cerebro-spinal fluid (CSF). Investigation with a phantom test object (of similar imaging characteristics to the brain) provided evidence for the validity of our image acquisition and analysis techniques. Both inter- and intra-rater reliability were found to be good in whole brain measures but less so for smaller regions. There were no statistically significant differences in positioning across the three study groups (patients with schizophrenia, high risk subjects and normal volunteers). A new technique for thresholding MRI scans longitudinally is described (the 'rescale' method) and compared with our established method (thresholding by eye). Few differences between the two techniques were seen at 3- and 6-month follow-up. These findings demonstrate the validity and reliability of the structural MRI analysis techniques used in the Edinburgh High Risk Project, and highlight methodological issues of general concern in cross-sectional and longitudinal studies of brain structure in healthy control subjects and neuropsychiatric populations.

  12. Development of a scale to assess cancer stigma in the non-patient population.

    PubMed

    Marlow, Laura A V; Wardle, Jane

    2014-04-23

    Illness-related stigma has attracted considerable research interest, but few studies have specifically examined stigmatisation of cancer in the non-patient population. The present study developed and validated a Cancer Stigma Scale (CASS) for use in the general population. An item pool was developed on the basis of previous research into illness-related stigma in the general population and patients with cancer. Two studies were carried out. The first study used Exploratory factor analysis to explore the structure of items in a sample of 462 postgraduate students recruited through a London university. The second study used Confirmatory factor analysis to confirm the structure among 238 adults recruited through an online market research panel. Internal reliability, test-retest reliability and construct validity were also assessed. Exploratory factor analysis suggested six subscales, representing: Awkwardness, Severity, Avoidance, Policy Opposition, Personal Responsibility and Financial Discrimination. Confirmatory factor analysis confirmed this structure with a 25-item scale. All subscales showed adequate to good internal and test-retest reliability in both samples. Construct validity was also good, with mean scores for each subscale varying in the expected directions by age, gender, experience of cancer, awareness of lifestyle risk factors for cancer, and social desirability. Means for the subscales were consistent across the two samples. These findings highlight the complexity of cancer stigma and provide the Cancer Stigma Scale (CASS) which can be used to compare populations, types of cancer and evaluate the effects of interventions designed to reduce cancer stigma in non-patient populations.

  13. A reduced factor structure for the PROQOL-HIV questionnaire provided reliable indicators of health-related quality of life.

    PubMed

    Lalanne, Christophe; Chassany, Olivier; Carrieri, Patrizia; Marcellin, Fabienne; Armstrong, Andrew R; Lert, France; Spire, Bruno; Dray-Spira, Rosemary; Duracinsky, Martin

    2016-04-01

    To identify a simplified factor structure for the PROQOL-human immunodeficiency virus (HIV) questionnaire to improve the measurement of the health-related quality of life (HRQL) of HIV-positive patients in clinical care and research settings. HRQL data were collected using the eight-dimension PROQOL-HIV questionnaire from 2,537 patients (VESPA2 study). Exploratory factor analysis (EFA) and confirmatory factor analysis (CFA) validated a simpler four-factor structure and assessed measurement invariance (MI). Multigroup analysis assessed the effect of sex, age, and antiretroviral therapy (ART) on the resulting factor scores. Correlations with symptom and Short Form (SF)-12 self-reports assessed convergent validity. Item analysis, EFA, and CFAs confirmed the validity [comparative fit index (CFI), 0.948; root mean square error of approximation, 0.064] and reliability (α's ≥ 0.8) of four dimensions: physical health and symptoms, health concerns and mental distress, social and intimate relationships, and treatment-related impact. Strong MI was demonstrated across sex and age (decrease in CFI <0.01). A multiple-cause multiple-indicator model indicated that HRQL correlated as expected with sex, age, and the ART status. Correlations of HRQL, symptom reports, and SF-12 scores evidenced convergent validity criterion. The simplified factor structure and scoring scheme for PROQOL-HIV will allow clinicians to monitor with greater reliability the HRQL of patients in clinical care and research settings. Copyright © 2016 Elsevier Inc. All rights reserved.

  14. Reliability-Based Stability Analysis of Rock Slopes Using Numerical Analysis and Response Surface Method

    NASA Astrophysics Data System (ADS)

    Dadashzadeh, N.; Duzgun, H. S. B.; Yesiloglu-Gultekin, N.

    2017-08-01

    While advanced numerical techniques in slope stability analysis are successfully used in deterministic studies, they have so far found limited use in probabilistic analyses due to their high computation cost. The first-order reliability method (FORM) is one of the most efficient probabilistic techniques to perform probabilistic stability analysis by considering the associated uncertainties in the analysis parameters. However, it is not possible to directly use FORM in numerical slope stability evaluations as it requires definition of a limit state performance function. In this study, an integrated methodology for probabilistic numerical modeling of rock slope stability is proposed. The methodology is based on response surface method, where FORM is used to develop an explicit performance function from the results of numerical simulations. The implementation of the proposed methodology is performed by considering a large potential rock wedge in Sumela Monastery, Turkey. The accuracy of the developed performance function to truly represent the limit state surface is evaluated by monitoring the slope behavior. The calculated probability of failure is compared with Monte Carlo simulation (MCS) method. The proposed methodology is found to be 72% more efficient than MCS, while the accuracy is decreased with an error of 24%.

  15. Neo-Deterministic and Probabilistic Seismic Hazard Assessments: a Comparative Analysis

    NASA Astrophysics Data System (ADS)

    Peresan, Antonella; Magrin, Andrea; Nekrasova, Anastasia; Kossobokov, Vladimir; Panza, Giuliano F.

    2016-04-01

    Objective testing is the key issue towards any reliable seismic hazard assessment (SHA). Different earthquake hazard maps must demonstrate their capability in anticipating ground shaking from future strong earthquakes before an appropriate use for different purposes - such as engineering design, insurance, and emergency management. Quantitative assessment of maps performances is an essential step also in scientific process of their revision and possible improvement. Cross-checking of probabilistic models with available observations and independent physics based models is recognized as major validation procedure. The existing maps from the classical probabilistic seismic hazard analysis (PSHA), as well as those from the neo-deterministic analysis (NDSHA), which have been already developed for several regions worldwide (including Italy, India and North Africa), are considered to exemplify the possibilities of the cross-comparative analysis in spotting out limits and advantages of different methods. Where the data permit, a comparative analysis versus the documented seismic activity observed in reality is carried out, showing how available observations about past earthquakes can contribute to assess performances of the different methods. Neo-deterministic refers to a scenario-based approach, which allows for consideration of a wide range of possible earthquake sources as the starting point for scenarios constructed via full waveforms modeling. The method does not make use of empirical attenuation models (i.e. Ground Motion Prediction Equations, GMPE) and naturally supplies realistic time series of ground shaking (i.e. complete synthetic seismograms), readily applicable to complete engineering analysis and other mitigation actions. The standard NDSHA maps provide reliable envelope estimates of maximum seismic ground motion from a wide set of possible scenario earthquakes, including the largest deterministically or historically defined credible earthquake. In addition, the flexibility of NDSHA allows for generation of ground shaking maps at specified long-term return times, which may permit a straightforward comparison between NDSHA and PSHA maps in terms of average rates of exceedance for specified time windows. The comparison of NDSHA and PSHA maps, particularly for very long recurrence times, may indicate to what extent probabilistic ground shaking estimates are consistent with those from physical models of seismic waves propagation. A systematic comparison over the territory of Italy is carried out exploiting the uniqueness of the Italian earthquake catalogue, a data set covering more than a millennium (a time interval about ten times longer than that available in most of the regions worldwide) with a satisfactory completeness level for M>5, which warrants the results of analysis. By analysing in some detail seismicity in the Vrancea region, we show that well constrained macroseismic field information for individual earthquakes may provide useful information about the reliability of ground shaking estimates. Finally, in order to generalise observations, the comparative analysis is extended to further regions where both standard NDSHA and PSHA maps are available (e.g. State of Gujarat, India). The final Global Seismic Hazard Assessment Program (GSHAP) results and the most recent version of Seismic Hazard Harmonization in Europe (SHARE) project maps, along with other national scale probabilistic maps, all obtained by PSHA, are considered for this comparative analysis.

  16. Inter-Rater Reliability and Validity of the Australian Football League’s Kicking and Handball Tests

    PubMed Central

    Cripps, Ashley J.; Hopper, Luke S.; Joyce, Christopher

    2015-01-01

    Talent identification tests used at the Australian Football League’s National Draft Combine assess the capacities of athletes to compete at a professional level. Tests created for the National Draft Combine are also commonly used for talent identification and athlete development in development pathways. The skills tests created by the Australian Football League required players to either handball (striking the ball with the hand) or kick to a series of 6 randomly generated targets. Assessors subjectively rate each skill execution giving a 0-5 score for each disposal. This study aimed to investigate the inter-rater reliability and validity of the skills tests at an adolescent sub-elite level. Male Australian footballers were recruited from sub-elite adolescent teams (n = 121, age = 15.7 ± 0.3 years, height = 1.77 ± 0.07 m, mass = 69.17 ± 8.08 kg). The coaches (n = 7) of each team were also recruited. Inter-rater reliability was assessed using Inter-class correlations (ICC) and Limits of Agreement statistics. Both the kicking (ICC = 0.96, p < .01) and handball tests (ICC = 0.89, p < .01) demonstrated strong reliability and acceptable levels of absolute agreement. Content validity was determined by examining the test scores sensitivity to laterality and distance. Concurrent validity was assessed by comparing coaches’ perceptions of skill to actual test outcomes. Multivariate analysis of variance (MANOVA) examined the main effect of laterality, with scores on the dominant hand (p = .04) and foot (p < .01) significantly higher compared to the non-dominant side. Follow-up univariate analysis reported significant differences at every distance in the kicking test. A poor correlation was found between coaches’ perceptions of skill and testing outcomes. The results of this study demonstrate both skill tests demonstrate acceptable inter-rater reliable. Partial content validity was confirmed for the kicking test, however further research is required to confirm validity of the handball test. Key points The skill tests created by the AFL demonstrated acceptable levels of relative and absolute inter-rater reliability. Both the AFL’s skills tests are able to differentiate between athletes dominant and non-dominant limbs. However, only the kicking test could consistently differentiated between score outcomes over a range of Australian Football specific disposal distances. Both tests demonstrated poor concurrent validity, with no correlation found between coaches’ perceptions of technical skills and actual skill outcomes measured. PMID:26336356

  17. Biomechanical analysis using Kinovea for sports application

    NASA Astrophysics Data System (ADS)

    Muaza Nor Adnan, Nor; Patar, Mohd Nor Azmi Ab; Lee, Hokyoo; Yamamoto, Shin-Ichiroh; Jong-Young, Lee; Mahmud, Jamaluddin

    2018-04-01

    This paper assesses the reliability of HD VideoCam–Kinovea as an alternative tool in conducting motion analysis and measuring knee relative angle of drop jump movement. The motion capture and analysis procedure were conducted in the Biomechanics Lab, Shibaura Institute of Technology, Omiya Campus, Japan. A healthy subject without any gait disorder (BMI of 28.60 ± 1.40) was recruited. The volunteered subject was asked to per the drop jump movement on preset platform and the motion was simultaneously recorded using an established infrared motion capture system (Hawk–Cortex) and a HD VideoCam in the sagittal plane only. The capture was repeated for 5 times. The outputs (video recordings) from the HD VideoCam were input into Kinovea (an open-source software) and the drop jump pattern was tracked and analysed. These data are compared with the drop jump pattern tracked and analysed earlier using the Hawk–Cortex system. In general, the results obtained (drop jump pattern) using the HD VideoCam–Kinovea are close to the results obtained using the established motion capture system. Basic statistical analyses show that most average variances are less than 10%, thus proving the repeatability of the protocol and the reliability of the results. It can be concluded that the integration of HD VideoCam–Kinovea has the potential to become a reliable motion capture–analysis system. Moreover, it is low cost, portable and easy to use. As a conclusion, the current study and its findings are found useful and has contributed to enhance significant knowledge pertaining to motion capture-analysis, drop jump movement and HD VideoCam–Kinovea integration.

  18. Management of reliability and maintainability; a disciplined approach to fleet readiness

    NASA Technical Reports Server (NTRS)

    Willoughby, W. J., Jr.

    1981-01-01

    Material acquisition fundamentals were reviewed and include: mission profile definition, stress analysis, derating criteria, circuit reliability, failure modes, and worst case analysis. Military system reliability was examined with emphasis on the sparing of equipment. The Navy's organizational strategy for 1980 is presented.

  19. DJ-1 is a reliable serum biomarker for discriminating high-risk endometrial cancer.

    PubMed

    Di Cello, Annalisa; Di Sanzo, Maddalena; Perrone, Francesca Marta; Santamaria, Gianluca; Rania, Erika; Angotti, Elvira; Venturella, Roberta; Mancuso, Serafina; Zullo, Fulvio; Cuda, Giovanni; Costanzo, Francesco

    2017-06-01

    New reliable approaches to stratify patients with endometrial cancer into risk categories are highly needed. We have recently demonstrated that DJ-1 is overexpressed in endometrial cancer, showing significantly higher levels both in serum and tissue of patients with high-risk endometrial cancer compared with low-risk endometrial cancer. In this experimental study, we further extended our observation, evaluating the role of DJ-1 as an accurate serum biomarker for high-risk endometrial cancer. A total of 101 endometrial cancer patients and 44 healthy subjects were prospectively recruited. DJ-1 serum levels were evaluated comparing cases and controls and, among endometrial cancer patients, between high- and low-risk patients. The results demonstrate that DJ-1 levels are significantly higher in cases versus controls and in high- versus low-risk patients. The receiver operating characteristic curve analysis shows that DJ-1 has a very good diagnostic accuracy in discriminating endometrial cancer patients versus controls and an excellent accuracy in distinguishing, among endometrial cancer patients, low- from high-risk cases. DJ-1 sensitivity and specificity are the highest when high- and low-risk patients are compared, reaching the value of 95% and 99%, respectively. Moreover, DJ-1 serum levels seem to be correlated with worsening of the endometrial cancer grade and histotype, making it a reliable tool in the preoperative decision-making process.

  20. Standard Setting Methods for Pass/Fail Decisions on High-Stakes Objective Structured Clinical Examinations: A Validity Study.

    PubMed

    Yousuf, Naveed; Violato, Claudio; Zuberi, Rukhsana W

    2015-01-01

    CONSTRUCT: Authentic standard setting methods will demonstrate high convergent validity evidence of their outcomes, that is, cutoff scores and pass/fail decisions, with most other methods when compared with each other. The objective structured clinical examination (OSCE) was established for valid, reliable, and objective assessment of clinical skills in health professions education. Various standard setting methods have been proposed to identify objective, reliable, and valid cutoff scores on OSCEs. These methods may identify different cutoff scores for the same examinations. Identification of valid and reliable cutoff scores for OSCEs remains an important issue and a challenge. Thirty OSCE stations administered at least twice in the years 2010-2012 to 393 medical students in Years 2 and 3 at Aga Khan University are included. Psychometric properties of the scores are determined. Cutoff scores and pass/fail decisions of Wijnen, Cohen, Mean-1.5SD, Mean-1SD, Angoff, borderline group and borderline regression (BL-R) methods are compared with each other and with three variants of cluster analysis using repeated measures analysis of variance and Cohen's kappa. The mean psychometric indices on the 30 OSCE stations are reliability coefficient = 0.76 (SD = 0.12); standard error of measurement = 5.66 (SD = 1.38); coefficient of determination = 0.47 (SD = 0.19), and intergrade discrimination = 7.19 (SD = 1.89). BL-R and Wijnen methods show the highest convergent validity evidence among other methods on the defined criteria. Angoff and Mean-1.5SD demonstrated least convergent validity evidence. The three cluster variants showed substantial convergent validity with borderline methods. Although there was a high level of convergent validity of Wijnen method, it lacks the theoretical strength to be used for competency-based assessments. The BL-R method is found to show the highest convergent validity evidences for OSCEs with other standard setting methods used in the present study. We also found that cluster analysis using mean method can be used for quality assurance of borderline methods. These findings should be further confirmed by studies in other settings.

  1. Immunogenicity testing of therapeutic antibodies in ocular fluids after intravitreal injection.

    PubMed

    Wessels, Uwe; Zadak, Markus; Reiser, Astrid; Brockhaus, Janis; Ritter, Mirko; Abdolzade-Bavil, Afsaneh; Heinrich, Julia; Stubenrauch, Kay

    2018-04-11

    High drug concentrations in ocular fluids after intravitreal administration preclude the use of drug-sensitive immunoassays. A drug-tolerant immunoassay is therefore desirable for immunogenicity testing in ophthalmology. Immune complex (IC) antidrug antibody (ADA) assays were established for two species. The assays were compared with the bridging assay in ocular and plasma samples from two preclinical studies. The IC assays showed high drug tolerance, which enabled a reliable ADA detection in ocular fluids after intravitreal administration. The IC assays were superior to the bridging assay in the analysis of ocular fluids with high drug concentrations. The IC assay allows a reliable ADA detection in matrices with high drug concentrations, such as ocular fluids.

  2. Numerical simulation of the cavitation characteristics of a mixed-flow pump

    NASA Astrophysics Data System (ADS)

    Chen, T.; Li, S. R.; Li, W. Z.; Liu, Y. L.; Wu, D. Z.; Wang, L. Q.

    2013-12-01

    As a kind of general equipment for fluid transportation, pumps were widely used in industry which includes many applications of high pressure, temperature and toxic fluids transportations. Performances of pumps affect the safety and reliability of the whole special equipment system. Cavitation in pumps cause the loss of performance and erosion of the blade, which could affect the running stability and reliability of the pump system. In this paper, a kind of numerical method for cavitaion performance prediction was presented. In order to investigate the accuracy of the method, CFD flow analysis and cavitation performance predictions of a mixed-flow pump were carried out. The numerical results were compared with the test results.

  3. Assessment of the impact of the scanner-related factors on brain morphometry analysis with Brainvisa

    PubMed Central

    2011-01-01

    Background Brain morphometry is extensively used in cross-sectional studies. However, the difference in the estimated values of the morphometric measures between patients and healthy subjects may be small and hence overshadowed by the scanner-related variability, especially with multicentre and longitudinal studies. It is important therefore to investigate the variability and reliability of morphometric measurements between different scanners and different sessions of the same scanner. Methods We assessed the variability and reliability for the grey matter, white matter, cerebrospinal fluid and cerebral hemisphere volumes as well as the global sulcal index, sulcal surface and mean geodesic depth using Brainvisa. We used datasets obtained across multiple MR scanners at 1.5 T and 3 T from the same groups of 13 and 11 healthy volunteers, respectively. For each morphometric measure, we conducted ANOVA analysis and verified whether the estimated values were significantly different across different scanners or different sessions of the same scanner. The between-centre and between-visit reliabilities were estimated from their contribution to the total variance, using a random-effects ANOVA model. To estimate the main processes responsible for low reliability, the results of brain segmentation were compared to those obtained using FAST within FSL. Results In a considerable number of cases, the main effects of both centre and visit factors were found to be significant. Moreover, both between-centre and between-visit reliabilities ranged from poor to excellent for most morphometric measures. A comparison between segmentation using Brainvisa and FAST revealed that FAST improved the reliabilities for most cases, suggesting that morphometry could benefit from improving the bias correction. However, the results were still significantly different across different scanners or different visits. Conclusions Our results confirm that for morphometry analysis with the current version of Brainvisa using data from multicentre or longitudinal studies, the scanner-related variability must be taken into account and where possible should be corrected for. We also suggest providing some flexibility to Brainvisa for a step-by-step analysis of the robustness of this package in terms of reproducibility of the results by allowing the bias corrected images to be imported from other packages and bias correction step be skipped, for example. PMID:22189342

  4. Multidisciplinary System Reliability Analysis

    NASA Technical Reports Server (NTRS)

    Mahadevan, Sankaran; Han, Song; Chamis, Christos C. (Technical Monitor)

    2001-01-01

    The objective of this study is to develop a new methodology for estimating the reliability of engineering systems that encompass multiple disciplines. The methodology is formulated in the context of the NESSUS probabilistic structural analysis code, developed under the leadership of NASA Glenn Research Center. The NESSUS code has been successfully applied to the reliability estimation of a variety of structural engineering systems. This study examines whether the features of NESSUS could be used to investigate the reliability of systems in other disciplines such as heat transfer, fluid mechanics, electrical circuits etc., without considerable programming effort specific to each discipline. In this study, the mechanical equivalence between system behavior models in different disciplines are investigated to achieve this objective. A new methodology is presented for the analysis of heat transfer, fluid flow, and electrical circuit problems using the structural analysis routines within NESSUS, by utilizing the equivalence between the computational quantities in different disciplines. This technique is integrated with the fast probability integration and system reliability techniques within the NESSUS code, to successfully compute the system reliability of multidisciplinary systems. Traditional as well as progressive failure analysis methods for system reliability estimation are demonstrated, through a numerical example of a heat exchanger system involving failure modes in structural, heat transfer and fluid flow disciplines.

  5. Multi-Disciplinary System Reliability Analysis

    NASA Technical Reports Server (NTRS)

    Mahadevan, Sankaran; Han, Song

    1997-01-01

    The objective of this study is to develop a new methodology for estimating the reliability of engineering systems that encompass multiple disciplines. The methodology is formulated in the context of the NESSUS probabilistic structural analysis code developed under the leadership of NASA Lewis Research Center. The NESSUS code has been successfully applied to the reliability estimation of a variety of structural engineering systems. This study examines whether the features of NESSUS could be used to investigate the reliability of systems in other disciplines such as heat transfer, fluid mechanics, electrical circuits etc., without considerable programming effort specific to each discipline. In this study, the mechanical equivalence between system behavior models in different disciplines are investigated to achieve this objective. A new methodology is presented for the analysis of heat transfer, fluid flow, and electrical circuit problems using the structural analysis routines within NESSUS, by utilizing the equivalence between the computational quantities in different disciplines. This technique is integrated with the fast probability integration and system reliability techniques within the NESSUS code, to successfully compute the system reliability of multi-disciplinary systems. Traditional as well as progressive failure analysis methods for system reliability estimation are demonstrated, through a numerical example of a heat exchanger system involving failure modes in structural, heat transfer and fluid flow disciplines.

  6. A Passive System Reliability Analysis for a Station Blackout

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brunett, Acacia; Bucknor, Matthew; Grabaskas, David

    2015-05-03

    The latest iterations of advanced reactor designs have included increased reliance on passive safety systems to maintain plant integrity during unplanned sequences. While these systems are advantageous in reducing the reliance on human intervention and availability of power, the phenomenological foundations on which these systems are built require a novel approach to a reliability assessment. Passive systems possess the unique ability to fail functionally without failing physically, a result of their explicit dependency on existing boundary conditions that drive their operating mode and capacity. Argonne National Laboratory is performing ongoing analyses that demonstrate various methodologies for the characterization of passivemore » system reliability within a probabilistic framework. Two reliability analysis techniques are utilized in this work. The first approach, the Reliability Method for Passive Systems, provides a mechanistic technique employing deterministic models and conventional static event trees. The second approach, a simulation-based technique, utilizes discrete dynamic event trees to treat time- dependent phenomena during scenario evolution. For this demonstration analysis, both reliability assessment techniques are used to analyze an extended station blackout in a pool-type sodium fast reactor (SFR) coupled with a reactor cavity cooling system (RCCS). This work demonstrates the entire process of a passive system reliability analysis, including identification of important parameters and failure metrics, treatment of uncertainties and analysis of results.« less

  7. Binge Eating Disorder: Reliability and Validity of a New Diagnostic Category.

    ERIC Educational Resources Information Center

    Brody, Michelle L.; And Others

    1994-01-01

    Examined reliability and validity of binge eating disorder (BED), proposed for inclusion in Diagnostic and Statistical Manual of Mental Disorders (DSM), fourth edition. Interrater reliability of BED diagnosis compared favorably with that of most diagnoses in DSM revised third edition. Study comparing obese individuals with and without BED and…

  8. State Education Indicators with a Focus on Title I: 2003-04

    ERIC Educational Resources Information Center

    Williams, Andra; Blank, Rolf K.; Toye, Carla; Petermann, Adam

    2007-01-01

    "State Education Indicators with a Focus on Title I: 2003-04" is the ninth in a series of reports designed to provide: (1) consistent, reliable indicators to allow analysis of trends for each state over time; (2) high quality, comparable state data; and (3) indicator formats designed for use by a diverse audience. Since its inception,…

  9. State Education Indicators with a Focus on Title I: 2002-03

    ERIC Educational Resources Information Center

    Williams, Andra; Blank, Rolf K.; Toye, Carla; Petermann, Adam

    2007-01-01

    This paper is the eighth in a series of reports designed to provide (1) consistent, reliable indicators to allow analysis of trends for each state over time, (2) high data quality for comparability from state to state, and (3) accessible indicator formats aimed toward facilitating use by a variety of audiences. Since its inception, the report has…

  10. An enquiry into the method of paired comparison: reliability, scaling, and Thurstone's Law of Comparative Judgment

    Treesearch

    Thomas C. Brown; George L. Peterson

    2009-01-01

    The method of paired comparisons is used to measure individuals' preference orderings of items presented to them as discrete binary choices. This paper reviews the theory and application of the paired comparison method, describes a new computer program available for eliciting the choices, and presents an analysis of methods for scaling paired choice data to...

  11. Otogenic Meningitis: A Comparison of Diagnostic Performance of Surgery and Radiology.

    PubMed

    Bruschini, Luca; Fortunato, Simona; Tascini, Carlo; Ciabotti, Annalisa; Leonildi, Alessandro; Bini, Belinda; Giuliano, Simone; Abbruzzese, Arturo; Berrettini, Stefano; Menichetti, Francesco

    2017-01-01

    Development of intracranial complications from middle ear infections might be difficult to diagnose. We compared radiological and surgical findings of 26 patients affected by otogenic meningitis. Results of our analysis showed that surgery is more reliable than imaging in revealing bone defects. Therefore, suggest that surgery be performed for diagnosis and eventual management of all cases of suspected otogenic meningitis.

  12. Reliability Generalization (RG) Analysis: The Test Is Not Reliable

    ERIC Educational Resources Information Center

    Warne, Russell

    2008-01-01

    Literature shows that most researchers are unaware of some of the characteristics of reliability. This paper clarifies some misconceptions by describing the procedures, benefits, and limitations of reliability generalization while using it to illustrate the nature of score reliability. Reliability generalization (RG) is a meta-analytic method…

  13. Electric system restructuring and system reliability

    NASA Astrophysics Data System (ADS)

    Horiuchi, Catherine Miller

    In 1996 the California legislature passed AB 1890, explicitly defining economic benefits and detailing specific mechanisms for initiating a partial restructuring the state's electric system. Critics have since sought re-regulation and proponents have asked for patience as the new institutions and markets take shape. Other states' electric system restructuring activities have been tempered by real and perceived problems in the California model. This study examines the reduced regulatory controls and new constraints introduced in California's limited restructuring model using utility and regulatory agency records from the 1990's to investigate effects of new institutions and practices on system reliability for the state's five largest public and private utilities. Logit and negative binomial regressions indicate negative impact from the California model of restructuring on system reliability as measured by customer interruptions. Time series analysis of outage data could not predict the wholesale power market collapse and the subsequent rolling blackouts in early 2001; inclusion of near-outage reliability disturbances---load shedding and energy emergencies---provided a measure of forewarning. Analysis of system disruptions, generation capacity and demand, and the role of purchased power challenge conventional wisdom on the causality of Californian's power problems. The quantitative analysis was supplemented by a targeted survey of electric system restructuring participants. Findings suggest each utility and the organization controlling the state's electric grid provided protection from power outages comparable to pre-restructuring operations through 2000; however, this reliability has come at an inflated cost, resulting in reduced system purchases and decreased marginal protection. The historic margin of operating safety has fully eroded, increasing mandatory load shedding and emergency declarations for voluntary and mandatory conservation. Proposed remedies focused on state-funded contracts and government-managed power authorities may not help, as the findings suggest pricing models, market uncertainty, interjurisdictional conflict and an inability to respond to market perturbations are more significant contributors to reduced regional generation availability than the particular contract mechanisms and funding sources used for power purchases.

  14. Reliability of the modified Tufts Lumbar Degenerative Disc Classification between neurosurgeons and neuroradiologists.

    PubMed

    Burke, Shane M; Hwang, Steven W; Mehan, William A; Bedi, Harprit S; Ogbuji, Richard; Riesenburger, Ron I

    2016-07-01

    Cross-specialty inter-rater reliability has not been explicitly reported for imaging characteristics that are thought to be important in lumbar intervertebral disc degeneration. Sufficient cross-specialty reliability is an essential consideration if radiographic stratification of symptomatic patients to specific treatment modalities is to ever be realized. Therefore the purpose of this study was to directly compare the assessment of such characteristics between neurosurgeons and neuroradiologists. Sixty consecutive patients with a diagnosis of lumbago and appropriate imaging were selected for inclusion. Lumbar MRI were evaluated using the Tufts Degenerative Disc Classification by two neurosurgeons and two neuroradiologists. Inter-rater reliability was assessed using Cohen's κ values both within and between specialties. A sensitivity analysis was performed for a modified grading system, which excluded high intensity zones (HIZ), due to poor cross-specialty inter-rater reliability of HIZ between specialties. The reliability of HIZ between neurosurgeons and neuroradiologists was fair in two of the four cross-specialty comparisons in this study (neurosurgeon 1 versus both radiologists κ=0.364 and κ=0.290). Removing HIZ from the classification improved inter-rater reliability for all comparisons within and between specialties (0.465⩽κ⩽0.576). In addition, intra-rater reliability remained in the moderate to substantial range (0.523⩽κ⩽0.649). Given our findings and corroboration with previous studies, identification of HIZ seems to have a markedly variable reliability. Thus we recommend modification of the original Tufts Degenerative Disc Classification by removing HIZ in order to make the overall grade provided by this classification more reproducible when scored by practitioners of different training backgrounds. Copyright © 2015 Elsevier Ltd. All rights reserved.

  15. The reliability of three devices used for measuring vertical jump height.

    PubMed

    Nuzzo, James L; Anning, Jonathan H; Scharfenberg, Jessica M

    2011-09-01

    The purpose of this investigation was to assess the intrasession and intersession reliability of the Vertec, Just Jump System, and Myotest for measuring countermovement vertical jump (CMJ) height. Forty male and 39 female university students completed 3 maximal-effort CMJs during 2 testing sessions, which were separated by 24-48 hours. The height of the CMJ was measured from all 3 devices simultaneously. Systematic error, relative reliability, absolute reliability, and heteroscedasticity were assessed for each device. Systematic error across the 3 CMJ trials was observed within both sessions for males and females, and this was most frequently observed when the CMJ height was measured by the Vertec. No systematic error was discovered across the 2 testing sessions when the maximum CMJ heights from the 2 sessions were compared. In males, the Myotest demonstrated the best intrasession reliability (intraclass correlation coefficient [ICC] = 0.95; SEM = 1.5 cm; coefficient of variation [CV] = 3.3%) and intersession reliability (ICC = 0.88; SEM = 2.4 cm; CV = 5.3%; limits of agreement = -0.08 ± 4.06 cm). Similarly, in females, the Myotest demonstrated the best intrasession reliability (ICC = 0.91; SEM = 1.4 cm; CV = 4.5%) and intersession reliability (ICC = 0.92; SEM = 1.3 cm; CV = 4.1%; limits of agreement = 0.33 ± 3.53 cm). Additional analysis revealed that heteroscedasticity was present in the CMJ when measured from all 3 devices, indicating that better jumpers demonstrate greater fluctuations in CMJ scores across testing sessions. To attain reliable CMJ height measurements, practitioners are encouraged to familiarize athletes with the CMJ technique and then allow the athletes to complete numerous repetitions until performance plateaus, particularly if the Vertec is being used.

  16. Comparison of sea level pressure reconstructions from western North American tree rings with a proxy record of winter severity in Japan

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gordon, G.A.; Lough, J.M.; Fritts, H.C.

    Reconstructions of winter (December-February) sea level pressure (SLP) from western North American tree-ring chronologies are compared with a proxy record of winter severity in Japan derived from the historically documented freeze dates of Lake Suwa. The SLP reconstructions extend from 1602 to 1961 and freeze dates from 1443 to 1954. The instrumental and reconstructed SLP for the 20th century reveal two distinct circulation regimes (teleconnection patterns) over the North Pacific that appear to be associated with severe and mild winters and, consequently, with early and late freezing of the lake. The reconstructed SLPO anomaly map for severe winters prior tomore » 1683 shows a pattern similar to those in the instrumental and reconstructed records of the 20th century. The analysis reveals that the reliability of the reconstruction may vary with the configuration of the actual SLP pattern as the mild winter pattern is not as well reconstructed as the severe winter pattern. That result illustrates the importance of testing the reliability of a reconstruction within the context of the intended interpretation. This analysis demonstrates how different types of proxy climate data can be compared and verified.« less

  17. Analysis Method for Laterally Loaded Pile Groups Using an Advanced Modeling of Reinforced Concrete Sections.

    PubMed

    Stacul, Stefano; Squeglia, Nunziante

    2018-02-15

    A Boundary Element Method (BEM) approach was developed for the analysis of pile groups. The proposed method includes: the non-linear behavior of the soil by a hyperbolic modulus reduction curve; the non-linear response of reinforced concrete pile sections, also taking into account the influence of tension stiffening; the influence of suction by increasing the stiffness of shallow portions of soil and modeled using the Modified Kovacs model; pile group shadowing effect, modeled using an approach similar to that proposed in the Strain Wedge Model for pile groups analyses. The proposed BEM method saves computational effort compared to more sophisticated codes such as VERSAT-P3D, PLAXIS 3D and FLAC-3D, and provides reliable results using input data from a standard site investigation. The reliability of this method was verified by comparing results from data from full scale and centrifuge tests on single piles and pile groups. A comparison is presented between measured and computed data on a laterally loaded fixed-head pile group composed by reinforced concrete bored piles. The results of the proposed method are shown to be in good agreement with those obtained in situ.

  18. Whole-loop mitochondrial DNA D-loop sequence variability in Egyptian Arabian equine matrilines

    PubMed Central

    Hudson, William

    2017-01-01

    Background Egyptian Arabian horses have been maintained in a state of genetic isolation for over a hundred years. There is only limited genetic proof that the studbook records of female lines of Egyptian Arabian pedigrees are reliable. This study characterized the mitochondrial DNA (mtDNA) signatures of 126 horses representing 14 matrilines in the Egyptian Agricultural Organization (EAO) horse-breeding program. Findings Analysis of the whole D-loop sequence yielded additional information compared to hypervariable region-1 (HVR1) analysis alone, with 42 polymorphic sites representing ten haplotypes compared to 16 polymorphic sites representing nine haplotypes, respectively. Most EAO haplotypes belonged to ancient haplogroups, suggesting origin from a wide geographical area over many thousands of years, although one haplotype was novel. Conclusions Historical families share haplotypes and some individuals from different strains belonged to the same haplogroup: the classical EAO strain designation is not equivalent to modern monophyletic matrilineal groups. Phylogenetic inference showed that the foundation mares of the historical haplotypes were highly likely to have the same haplotypes as the animals studied (p > 0.998 in all cases), confirming the reliability of EAO studbook records and providing the opportunity for breeders to confirm the ancestry of their horses. PMID:28859174

  19. Analysis Method for Laterally Loaded Pile Groups Using an Advanced Modeling of Reinforced Concrete Sections

    PubMed Central

    2018-01-01

    A Boundary Element Method (BEM) approach was developed for the analysis of pile groups. The proposed method includes: the non-linear behavior of the soil by a hyperbolic modulus reduction curve; the non-linear response of reinforced concrete pile sections, also taking into account the influence of tension stiffening; the influence of suction by increasing the stiffness of shallow portions of soil and modeled using the Modified Kovacs model; pile group shadowing effect, modeled using an approach similar to that proposed in the Strain Wedge Model for pile groups analyses. The proposed BEM method saves computational effort compared to more sophisticated codes such as VERSAT-P3D, PLAXIS 3D and FLAC-3D, and provides reliable results using input data from a standard site investigation. The reliability of this method was verified by comparing results from data from full scale and centrifuge tests on single piles and pile groups. A comparison is presented between measured and computed data on a laterally loaded fixed-head pile group composed by reinforced concrete bored piles. The results of the proposed method are shown to be in good agreement with those obtained in situ. PMID:29462857

  20. Normalized Rotational Multiple Yield Surface Framework (NRMYSF) stress-strain curve prediction method based on small strain triaxial test data on undisturbed Auckland residual clay soils

    NASA Astrophysics Data System (ADS)

    Noor, M. J. Md; Ibrahim, A.; Rahman, A. S. A.

    2018-04-01

    Small strain triaxial test measurement is considered to be significantly accurate compared to the external strain measurement using conventional method due to systematic errors normally associated with the test. Three submersible miniature linear variable differential transducer (LVDT) mounted on yokes which clamped directly onto the soil sample at equally 120° from the others. The device setup using 0.4 N resolution load cell and 16 bit AD converter was capable of consistently resolving displacement of less than 1µm and measuring axial strains ranging from less than 0.001% to 2.5%. Further analysis of small strain local measurement data was performed using new Normalized Multiple Yield Surface Framework (NRMYSF) method and compared with existing Rotational Multiple Yield Surface Framework (RMYSF) prediction method. The prediction of shear strength based on combined intrinsic curvilinear shear strength envelope using small strain triaxial test data confirmed the significant improvement and reliability of the measurement and analysis methods. Moreover, the NRMYSF method shows an excellent data prediction and significant improvement toward more reliable prediction of soil strength that can reduce the cost and time of experimental laboratory test.

  1. A proposed method to investigate reliability throughout a questionnaire

    PubMed Central

    2011-01-01

    Background Questionnaires are used extensively in medical and health care research and depend on validity and reliability. However, participants may differ in interest and awareness throughout long questionnaires, which can affect reliability of their answers. A method is proposed for "screening" of systematic change in random error, which could assess changed reliability of answers. Methods A simulation study was conducted to explore whether systematic change in reliability, expressed as changed random error, could be assessed using unsupervised classification of subjects by cluster analysis (CA) and estimation of intraclass correlation coefficient (ICC). The method was also applied on a clinical dataset from 753 cardiac patients using the Jalowiec Coping Scale. Results The simulation study showed a relationship between the systematic change in random error throughout a questionnaire and the slope between the estimated ICC for subjects classified by CA and successive items in a questionnaire. This slope was proposed as an awareness measure - to assessing if respondents provide only a random answer or one based on a substantial cognitive effort. Scales from different factor structures of Jalowiec Coping Scale had different effect on this awareness measure. Conclusions Even though assumptions in the simulation study might be limited compared to real datasets, the approach is promising for assessing systematic change in reliability throughout long questionnaires. Results from a clinical dataset indicated that the awareness measure differed between scales. PMID:21974842

  2. The 747 primary flight control systems reliability and maintenance study

    NASA Technical Reports Server (NTRS)

    1979-01-01

    The major operational characteristics of the 747 Primary Flight Control Systems (PFCS) are described. Results of reliability analysis for separate control functions are presented. The analysis makes use of a NASA computer program which calculates reliability of redundant systems. Costs for maintaining the 747 PFCS in airline service are assessed. The reliabilities and cost will provide a baseline for use in trade studies of future flight control system design.

  3. Optimization of urinary dipstick pH: Are multiple dipstick pH readings reliably comparable to commercial 24-hour urinary pH?

    PubMed

    Abbott, Joel E; Miller, Daniel L; Shi, William; Wenzler, David; Elkhoury, Fuad F; Patel, Nishant D; Sur, Roger L

    2017-09-01

    Accurate measurement of pH is necessary to guide medical management of nephrolithiasis. Urinary dipsticks offer a convenient method to measure pH, but prior studies have only assessed the accuracy of a single, spot dipstick. Given the known diurnal variation in pH, a single dipstick pH is unlikely to reflect the average daily urinary pH. Our goal was to determine whether multiple dipstick pH readings would be reliably comparable to pH from a 24-hour urine analysis. Kidney stone patients undergoing a 24-hour urine collection were enrolled and took images of dipsticks from their first 3 voids concurrently with the 24-hour collection. Images were sent to and read by a study investigator. The individual and mean pH from the dipsticks were compared to the 24-hour urine pH and considered to be accurate if the dipstick readings were within 0.5 of the 24-hour urine pH. The Bland-Altman test of agreement was used to further compare dipstick pH relative to 24-hour urine pH. Fifty-nine percent of patients had mean urinary pH values within 0.5 pH units of their 24-hour urine pH. Bland-Altman analysis showed a mean difference between dipstick pH and 24-hour urine pH of -0.22, with an upper limit of agreement of 1.02 (95% confidence interval [CI], 0.45-1.59) and a lower limit of agreement of -1.47 (95% CI, -2.04 to -0.90). We concluded that urinary dipstick based pH measurement lacks the precision required to guide medical management of nephrolithiasis and physicians should use 24-hour urine analysis to base their metabolic therapy.

  4. [Validity and Reliability of Korean Version of the Spiritual Care Competence Scale].

    PubMed

    Chung, Mi Ja; Park, Youngrye; Eun, Young

    2016-12-01

    The aim of this study was to examine the validity and reliability of the Korean Version of the Spiritual Care Competence Scale (K-SCCS). A cross-sectional study design was used. The K-SCCS consisted of 26 questions to measure spiritual care competence of nurses. Participants, 228 nurses who had more than 3 years'experience as a nurse, completed the survey. Confirmatory factor analysis was used to examine the construct validity and correlations of K-SCCS and spiritual well-being (SWB) were used to examine the criterion validity of K-SCCS. Cronbach's alpha was used to test internal consistency. The construct and the criterion-related validity of K-SCCS were supported as measures of spiritual care competence. Cronbach's alpha was .95. Factor loadings of the 26 questions ranged from .60 to .96. Construct validity of K-SCCS was verified by confirmatory factor analysis (RMSEA=.08, CFI=.90, NFI=.85). Criterion validity compared to the SWB showed significant correlation (r=.44, p<.001). The findings suggest that K-SCCS serves as an appropriate measure of spiritual care competence with validity and reliability. However, further study is needed to retest the verification of the factor analysis related to factor 2 (professionalisation and improving the quality of spiritual care) and factor 3 (personal support and patient counseling). Therefore, we recommend using the total score without distinguishing subscales.

  5. Software analysis handbook: Software complexity analysis and software reliability estimation and prediction

    NASA Technical Reports Server (NTRS)

    Lee, Alice T.; Gunn, Todd; Pham, Tuan; Ricaldi, Ron

    1994-01-01

    This handbook documents the three software analysis processes the Space Station Software Analysis team uses to assess space station software, including their backgrounds, theories, tools, and analysis procedures. Potential applications of these analysis results are also presented. The first section describes how software complexity analysis provides quantitative information on code, such as code structure and risk areas, throughout the software life cycle. Software complexity analysis allows an analyst to understand the software structure, identify critical software components, assess risk areas within a software system, identify testing deficiencies, and recommend program improvements. Performing this type of analysis during the early design phases of software development can positively affect the process, and may prevent later, much larger, difficulties. The second section describes how software reliability estimation and prediction analysis, or software reliability, provides a quantitative means to measure the probability of failure-free operation of a computer program, and describes the two tools used by JSC to determine failure rates and design tradeoffs between reliability, costs, performance, and schedule.

  6. Reliability and accuracy analysis of a new semiautomatic radiographic measurement software in adult scoliosis.

    PubMed

    Aubin, Carl-Eric; Bellefleur, Christian; Joncas, Julie; de Lanauze, Dominic; Kadoury, Samuel; Blanke, Kathy; Parent, Stefan; Labelle, Hubert

    2011-05-20

    Radiographic software measurement analysis in adult scoliosis. To assess the accuracy as well as the intra- and interobserver reliability of measuring different indices on preoperative adult scoliosis radiographs using a novel measurement software that includes a calibration procedure and semiautomatic features to facilitate the measurement process. Scoliosis requires a careful radiographic evaluation to assess the deformity. Manual and computer radiographic process measures have been studied extensively to determine the reliability and reproducibility in adolescent idiopathic scoliosis. Most studies rely on comparing given measurements, which are repeated by the same user or by an expert user. A given measure with a small intra- or interobserver error might be deemed as good repeatability, but all measurements might not be truly accurate because the ground-truth value is often unknown. Thorough accuracy assessment of radiographic measures is necessary to assess scoliotic deformities, compare these measures at different stages or to permit valid multicenter studies. Thirty-four sets of adult scoliosis digital radiographs were measured two times by three independent observers using a novel radiographic measurement software that includes semiautomatic features to facilitate the measurement process. Twenty different measures taken from the Spinal Deformity Study Group radiographic measurement manual were performed on the coronal and sagittal images. Intra- and intermeasurer reliability for each measure was assessed. The accuracy of the measurement software was also assessed using a physical spine model in six different scoliotic configurations as a true reference. The majority of the measures demonstrated good to excellent intra- and intermeasurer reliability, except for sacral obliquity. The standard variation of all the measures was very small: ≤ 4.2° for Cobb angles, ≤ 4.2° for the kyphosis, ≤ 5.7° for the lordosis, ≤ 3.9° for the pelvic angles, and ≤5.3° for the sacral angles. The variability in the linear measurements (distances) was <4 mm. The variance of the measures was 1.7 and 2.6 times greater, respectively, for the angular and linear measures between the inter- and intrameasurer reliability. The image quality positively influenced the intermeasurer reliability especially for the proximal thoracic Cobb angle, T10-L2 lordosis, sacral slope and L5 seating. The accuracy study revealed that on average the difference in the angular measures was < 2° for the Cobb angles, and < 4° for the other angles, except T2-T12 kyphosis (5.3°). The linear measures were all <3.5 mm difference on average. The majority of the measures, which were analyzed in this study demonstrated good to excellent reliability and accuracy. The novel semiautomatic measurement software can be recommended for use for clinical, research or multicenter study purposes.

  7. Analysis of environmental microplastics by vibrational microspectroscopy: FTIR, Raman or both?

    PubMed

    Käppler, Andrea; Fischer, Dieter; Oberbeckmann, Sonja; Schernewski, Gerald; Labrenz, Matthias; Eichhorn, Klaus-Jochen; Voit, Brigitte

    2016-11-01

    The contamination of aquatic ecosystems with microplastics has recently been reported through many studies, and negative impacts on the aquatic biota have been described. For the chemical identification of microplastics, mainly Fourier transform infrared (FTIR) and Raman spectroscopy are used. But up to now, a critical comparison and validation of both spectroscopic methods with respect to microplastics analysis is missing. To close this knowledge gap, we investigated environmental samples by both Raman and FTIR spectroscopy. Firstly, particles and fibres >500 μm extracted from beach sediment samples were analysed by Raman and FTIR microspectroscopic single measurements. Our results illustrate that both methods are in principle suitable to identify microplastics from the environment. However, in some cases, especially for coloured particles, a combination of both spectroscopic methods is necessary for a complete and reliable characterisation of the chemical composition. Secondly, a marine sample containing particles <400 μm was investigated by Raman imaging and FTIR transmission imaging. The results were compared regarding number, size and type of detectable microplastics as well as spectra quality, measurement time and handling. We show that FTIR imaging leads to significant underestimation (about 35 %) of microplastics compared to Raman imaging, especially in the size range <20 μm. However, the measurement time of Raman imaging is considerably higher compared to FTIR imaging. In summary, we propose a further size division within the smaller microplastics fraction into 500-50 μm (rapid and reliable analysis by FTIR imaging) and into 50-1 μm (detailed and more time-consuming analysis by Raman imaging). Graphical Abstract Marine microplastic sample (fraction <400 μm) on a silicon filter (middle) with the corresponding Raman and IR images.

  8. Royal London space analysis: plaster versus digital model assessment.

    PubMed

    Grewal, Balpreet; Lee, Robert T; Zou, Lifong; Johal, Ama

    2017-06-01

    With the advent of digital study models, the importance of being able to evaluate space requirements becomes valuable to treatment planning and the justification for any required extraction pattern. This study was undertaken to compare the validity and reliability of the Royal London space analysis (RLSA) undertaken on plaster as compared with digital models. A pilot study (n = 5) was undertaken on plaster and digital models to evaluate the feasibility of digital space planning. This also helped to determine the sample size calculation and as a result, 30 sets of study models with specified inclusion criteria were selected. All five components of the RLSA, namely: crowding; depth of occlusal curve; arch expansion/contraction; incisor antero-posterior advancement and inclination (assessed from the pre-treatment lateral cephalogram) were accounted for in relation to both model types. The plaster models served as the gold standard. Intra-operator measurement error (reliability) was evaluated along with a direct comparison of the measured digital values (validity) with the plaster models. The measurement error or coefficient of repeatability was comparable for plaster and digital space analyses and ranged from 0.66 to 0.95mm. No difference was found between the space analysis performed in either the upper or lower dental arch. Hence, the null hypothesis was accepted. The digital model measurements were consistently larger, albeit by a relatively small amount, than the plaster models (0.35mm upper arch and 0.32mm lower arch). No difference was detected in the RLSA when performed using either plaster or digital models. Thus, digital space analysis provides a valid and reproducible alternative method in the new era of digital records. © The Author 2016. Published by Oxford University Press on behalf of the European Orthodontic Society. All rights reserved. For permissions, please email: journals.permissions@oup.com

  9. 3D photography is as accurate as digital planimetry tracing in determining burn wound area.

    PubMed

    Stockton, K A; McMillan, C M; Storey, K J; David, M C; Kimble, R M

    2015-02-01

    In the paediatric population careful attention needs to be made concerning techniques utilised for wound assessment to minimise discomfort and stress to the child. To investigate whether 3D photography is a valid measure of burn wound area in children compared to the current clinical gold standard method of digital planimetry using Visitrak™. Twenty-five children presenting to the Stuart Pegg Paediatric Burn Centre for burn dressing change following acute burn injury were included in the study. Burn wound area measurement was undertaken using both digital planimetry (Visitrak™ system) and 3D camera analysis. Inter-rater reliability of the 3D camera software was determined by three investigators independently assessing the burn wound area. A comparison of wound area was assessed using intraclass correlation co-efficients (ICC) which demonstrated excellent agreement 0.994 (CI 0.986, 0.997). Inter-rater reliability measured using ICC 0.989 (95% CI 0.979, 0.995) demonstrated excellent inter-rater reliability. Time taken to map the wound was significantly quicker using the camera at bedside compared to Visitrak™ 14.68 (7.00)s versus 36.84 (23.51)s (p<0.001). In contrast, analysing wound area was significantly quicker using the Visitrak™ tablet compared to Dermapix(®) software for the 3D Images 31.36 (19.67)s versus 179.48 (56.86)s (p<0.001). This study demonstrates that images taken with the 3D LifeViz™ camera and assessed with Dermapix(®) software is a reliable method for wound area assessment in the acute paediatric burn setting. Copyright © 2014 Elsevier Ltd and ISBI. All rights reserved.

  10. Check-Standard Testing Across Multiple Transonic Wind Tunnels with the Modern Design of Experiments

    NASA Technical Reports Server (NTRS)

    Deloach, Richard

    2012-01-01

    This paper reports the result of an analysis of wind tunnel data acquired in support of the Facility Analysis Verification & Operational Reliability (FAVOR) project. The analysis uses methods referred to collectively at Langley Research Center as the Modern Design of Experiments (MDOE). These methods quantify the total variance in a sample of wind tunnel data and partition it into explained and unexplained components. The unexplained component is further partitioned in random and systematic components. This analysis was performed on data acquired in similar wind tunnel tests executed in four different U.S. transonic facilities. The measurement environment of each facility was quantified and compared.

  11. Computing Reliabilities Of Ceramic Components Subject To Fracture

    NASA Technical Reports Server (NTRS)

    Nemeth, N. N.; Gyekenyesi, J. P.; Manderscheid, J. M.

    1992-01-01

    CARES calculates fast-fracture reliability or failure probability of macroscopically isotropic ceramic components. Program uses results from commercial structural-analysis program (MSC/NASTRAN or ANSYS) to evaluate reliability of component in presence of inherent surface- and/or volume-type flaws. Computes measure of reliability by use of finite-element mathematical model applicable to multiple materials in sense model made function of statistical characterizations of many ceramic materials. Reliability analysis uses element stress, temperature, area, and volume outputs, obtained from two-dimensional shell and three-dimensional solid isoparametric or axisymmetric finite elements. Written in FORTRAN 77.

  12. Validation of the Japanese version of the Pediatric Quality of Life Inventory (PedsQL) Cancer Module.

    PubMed

    Tsuji, Naoko; Kakee, Naoko; Ishida, Yasushi; Asami, Keiko; Tabuchi, Ken; Nakadate, Hisaya; Iwai, Tsuyako; Maeda, Miho; Okamura, Jun; Kazama, Takuro; Terao, Yoko; Ohyama, Wataru; Yuza, Yuki; Kaneko, Takashi; Manabe, Atsushi; Kobayashi, Kyoko; Kamibeppu, Kiyoko; Matsushima, Eisuke

    2011-04-10

    The PedsQL 3.0 Cancer Module is a widely used instrument to measure pediatric cancer specific health-related quality of life (HRQOL) for children aged 2 to 18 years. We developed the Japanese version of the PedsQL Cancer Module and investigated its reliability and validity among Japanese children and their parents. Participants were 212 children with cancer and 253 of their parents. Reliability was determined by internal consistency using Cronbach's coefficient alpha and test-retest reliability using intra-class correlation coefficient (ICC). Validity was assessed through factor validity, convergent and discriminant validity, concurrent validity, and clinical validity. Factor validity was examined by exploratory factor analysis. Convergent and discriminant validity were examined by multitrait scaling analysis. Concurrent validity was assessed using Spearman's correlation coefficients between the Cancer Module and Generic Core Scales, and the comparison of the scores of child self-reports with those of other self-rating depression scales for children. Clinical validity was assessed by comparing the on- and off- treatment scores using Kruskal-Wallis and Mann-Whitney U tests. Cronbach's coefficient alpha was over 0.70 for the total scale and over 0.60 for each subscale by age except for the 'pain and hurt' subscale for children aged 5 to 7 years. For test-retest reliability, the ICC exceeded 0.70 for the total scale for each age. Exploratory factor analysis demonstrated sufficient factorial validity. Multitrait scaling analysis showed high success rates. Strong correlations were found between the reports by children and their parents, and the scores of the Cancer Module and the Generic Core Scales except for 'treatment anxiety' subscales for child reports. The Depression Self-Rating Scale for Children (DSRS-C) scores were significantly correlated with emotional domains and the total score of the cancer module. Children who had been off treatment over 12 months demonstrated significantly higher scores than those on treatment. The results demonstrate the reliability and validity of the Japanese version of the PedsQL Cancer Module among Japanese children.

  13. Validity and reliability of acoustic analysis of respiratory sounds in infants

    PubMed Central

    Elphick, H; Lancaster, G; Solis, A; Majumdar, A; Gupta, R; Smyth, R

    2004-01-01

    Objective: To investigate the validity and reliability of computerised acoustic analysis in the detection of abnormal respiratory noises in infants. Methods: Blinded, prospective comparison of acoustic analysis with stethoscope examination. Validity and reliability of acoustic analysis were assessed by calculating the degree of observer agreement using the κ statistic with 95% confidence intervals (CI). Results: 102 infants under 18 months were recruited. Convergent validity for agreement between stethoscope examination and acoustic analysis was poor for wheeze (κ = 0.07 (95% CI, –0.13 to 0.26)) and rattles (κ = 0.11 (–0.05 to 0.27)) and fair for crackles (κ = 0.36 (0.18 to 0.54)). Both the stethoscope and acoustic analysis distinguished well between sounds (discriminant validity). Agreement between observers for the presence of wheeze was poor for both stethoscope examination and acoustic analysis. Agreement for rattles was moderate for the stethoscope but poor for acoustic analysis. Agreement for crackles was moderate using both techniques. Within-observer reliability for all sounds using acoustic analysis was moderate to good. Conclusions: The stethoscope is unreliable for assessing respiratory sounds in infants. This has important implications for its use as a diagnostic tool for lung disorders in infants, and confirms that it cannot be used as a gold standard. Because of the unreliability of the stethoscope, the validity of acoustic analysis could not be demonstrated, although it could discriminate between sounds well and showed good within-observer reliability. For acoustic analysis, targeted training and the development of computerised pattern recognition systems may improve reliability so that it can be used in clinical practice. PMID:15499065

  14. Comprehensive Design Reliability Activities for Aerospace Propulsion Systems

    NASA Technical Reports Server (NTRS)

    Christenson, R. L.; Whitley, M. R.; Knight, K. C.

    2000-01-01

    This technical publication describes the methodology, model, software tool, input data, and analysis result that support aerospace design reliability studies. The focus of these activities is on propulsion systems mechanical design reliability. The goal of these activities is to support design from a reliability perspective. Paralleling performance analyses in schedule and method, this requires the proper use of metrics in a validated reliability model useful for design, sensitivity, and trade studies. Design reliability analysis in this view is one of several critical design functions. A design reliability method is detailed and two example analyses are provided-one qualitative and the other quantitative. The use of aerospace and commercial data sources for quantification is discussed and sources listed. A tool that was developed to support both types of analyses is presented. Finally, special topics discussed include the development of design criteria, issues of reliability quantification, quality control, and reliability verification.

  15. Applying reliability analysis to design electric power systems for More-electric aircraft

    NASA Astrophysics Data System (ADS)

    Zhang, Baozhu

    The More-Electric Aircraft (MEA) is a type of aircraft that replaces conventional hydraulic and pneumatic systems with electrically powered components. These changes have significantly challenged the aircraft electric power system design. This thesis investigates how reliability analysis can be applied to automatically generate system topologies for the MEA electric power system. We first use a traditional method of reliability block diagrams to analyze the reliability level on different system topologies. We next propose a new methodology in which system topologies, constrained by a set reliability level, are automatically generated. The path-set method is used for analysis. Finally, we interface these sets of system topologies with control synthesis tools to automatically create correct-by-construction control logic for the electric power system.

  16. Durability reliability analysis for corroding concrete structures under uncertainty

    NASA Astrophysics Data System (ADS)

    Zhang, Hao

    2018-02-01

    This paper presents a durability reliability analysis of reinforced concrete structures subject to the action of marine chloride. The focus is to provide insight into the role of epistemic uncertainties on durability reliability. The corrosion model involves a number of variables whose probabilistic characteristics cannot be fully determined due to the limited availability of supporting data. All sources of uncertainty, both aleatory and epistemic, should be included in the reliability analysis. Two methods are available to formulate the epistemic uncertainty: the imprecise probability-based method and the purely probabilistic method in which the epistemic uncertainties are modeled as random variables. The paper illustrates how the epistemic uncertainties are modeled and propagated in the two methods, and shows how epistemic uncertainties govern the durability reliability.

  17. Advancing methods for reliably assessing motivational interviewing fidelity using the Motivational Interviewing Skills Code

    PubMed Central

    Lord, Sarah Peregrine; Can, Doğan; Yi, Michael; Marin, Rebeca; Dunn, Christopher W.; Imel, Zac E.; Georgiou, Panayiotis; Narayanan, Shrikanth; Steyvers, Mark; Atkins, David C.

    2014-01-01

    The current paper presents novel methods for collecting MISC data and accurately assessing reliability of behavior codes at the level of the utterance. The MISC 2.1 was used to rate MI interviews from five randomized trials targeting alcohol and drug use. Sessions were coded at the utterance-level. Utterance-based coding reliability was estimated using three methods and compared to traditional reliability estimates of session tallies. Session-level reliability was generally higher compared to reliability using utterance-based codes, suggesting that typical methods for MISC reliability may be biased. These novel methods in MI fidelity data collection and reliability assessment provided rich data for therapist feedback and further analyses. Beyond implications for fidelity coding, utterance-level coding schemes may elucidate important elements in the counselor-client interaction that could inform theories of change and the practice of MI. PMID:25242192

  18. Advancing methods for reliably assessing motivational interviewing fidelity using the motivational interviewing skills code.

    PubMed

    Lord, Sarah Peregrine; Can, Doğan; Yi, Michael; Marin, Rebeca; Dunn, Christopher W; Imel, Zac E; Georgiou, Panayiotis; Narayanan, Shrikanth; Steyvers, Mark; Atkins, David C

    2015-02-01

    The current paper presents novel methods for collecting MISC data and accurately assessing reliability of behavior codes at the level of the utterance. The MISC 2.1 was used to rate MI interviews from five randomized trials targeting alcohol and drug use. Sessions were coded at the utterance-level. Utterance-based coding reliability was estimated using three methods and compared to traditional reliability estimates of session tallies. Session-level reliability was generally higher compared to reliability using utterance-based codes, suggesting that typical methods for MISC reliability may be biased. These novel methods in MI fidelity data collection and reliability assessment provided rich data for therapist feedback and further analyses. Beyond implications for fidelity coding, utterance-level coding schemes may elucidate important elements in the counselor-client interaction that could inform theories of change and the practice of MI. Copyright © 2015 Elsevier Inc. All rights reserved.

  19. Reliability Analysis of Retaining Walls Subjected to Blast Loading by Finite Element Approach

    NASA Astrophysics Data System (ADS)

    GuhaRay, Anasua; Mondal, Stuti; Mohiuddin, Hisham Hasan

    2018-02-01

    Conventional design methods adopt factor of safety as per practice and experience, which are deterministic in nature. The limit state method, though not completely deterministic, does not take into account effect of design parameters, which are inherently variable such as cohesion, angle of internal friction, etc. for soil. Reliability analysis provides a measure to consider these variations into analysis and hence results in a more realistic design. Several studies have been carried out on reliability of reinforced concrete walls and masonry walls under explosions. Also, reliability analysis of retaining structures against various kinds of failure has been done. However, very few research works are available on reliability analysis of retaining walls subjected to blast loading. Thus, the present paper considers the effect of variation of geotechnical parameters when a retaining wall is subjected to blast loading. However, it is found that the variation of geotechnical random variables does not have a significant effect on the stability of retaining walls subjected to blast loading.

  20. The validity and reliability of the type 2 diabetes and health promotion scale Turkish version: a methodological study.

    PubMed

    Yildiz, Esra; Kavuran, Esin

    2018-03-01

    A healthy promotion is important for maintaining health and preventing complications in patients with type 2 diabetes. The aim of the present study was to examine the psychometrics of a recently developed tool that can be used to screen for a health-promoting lifestyle in patients with type 2 diabetes. Data were collected from outpatients attending diabetes clinics. The Type 2 Diabetes and Health Promotion Scale (T2DHPS) and a demographic questionnaire were administered to 295 participants. Forward-backward translation of the original English version was used to develop a Turkish version. Internal consistency of the scale was assessed by Cronbach's alpha. An explanatory factor analysis and confirmatory factor analysis used validity of the Type 2 Diabetes and Health Promotion Scale - Turkish version. Kaiser-Meyer-Olkin (KMO) and Bartlett's sphericity tests showed that the sample met the criteria required for factor analysis. The reliability coefficient for the total scale was 0.84, and alpha coefficients for the subscales ranged from 0.57 to 0.92. A six-factor solution was obtained that explained 59.3% of the total variance. The ratio of chi-square statistics to degrees of freedom (χ 2 /df) 3.30 (χ 2 = 1157.48/SD = 350); error of root mean square approximation (RMSEA) 0.061; GFI value of 0.91 and comparative fit index (CFI) value was obtained as 0.91. Turkish version of The T2DHPS is a valid and reliable tool that can be used to assess patients' health-promoting lifestyle behaviours. Validity and reliability studies in different cultures and regions are recommended. © 2017 Nordic College of Caring Science.

  1. Can we scientifically and reliably measure the level of consciousness in vegetative and minimally conscious States? Rasch analysis of the coma recovery scale-revised.

    PubMed

    La Porta, Fabio; Caselli, Serena; Ianes, Aladar Bruno; Cameli, Olivia; Lino, Mario; Piperno, Roberto; Sighinolfi, Antonella; Lombardi, Francesco; Tennant, Alan

    2013-03-01

    (1) To appraise, by the means of Rasch analysis, the internal validity and reliability of the Coma Recovery Scale-Revised (CRS-R) in a sample of patients with disorder of consciousness (DOC); and (2) to provide information about the comparability of CRS-R scores across persons with DOC across different settings and groups, including different etiologies. Multicenter observational prospective study. Two rehabilitation wards, 1 intermediate care facility, and 2 nursing homes in Italy. Consecutively admitted patients (N=129) for which assessments at 2 different time points were available, giving a total sample of 258 observations. Not applicable. CRS-R. After controlling for any possible dependency between persons' measures collected at different time points, and for uniform differential item functioning by etiology showed by the visual subscale, Rasch analysis demonstrated adequate satisfaction of all the model's requirements, including adequate ordering of scoring categories, unidimensionality, local independence, invariance (χ(2)21=27.798, P=.146), and absence of differential item functioning across patients' sex, age, time, and setting. The reliability (person separation index=.896) was adequate for individual person measurement. We devised a practical raw score to measure conversion tables based on the CRS-R calibrations. The CRS-R is a psychometrically sound and robust measurement tool. The linear measures of ability derived from the CRS-R total scores do satisfy all the principles of scientific measurement and are sufficiently reliable for high stakes assessments, such as the diagnosis of the level of consciousness in individual patients. Future studies are needed to directly explore the capabilities of the CRS-R measures to reduce the risk of vegetative state misdiagnosis. Copyright © 2013 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  2. [Validity and reliability of Pediatric Quality of Life Inventory Version 4.0 Generic Core Scales in Chinese children and adolescents].

    PubMed

    Chen, Yu-Ming; He, Li-Ping; Mai, Jin-Cheng; Hao, Yuan-Tao; Xiong, Li-Hua; Chen, Wei-Qing; Wu, Jiang-Nan

    2008-06-01

    To evaluate the reliability and validity of parent proxy-report scales of Pediatric Quality of Life Inventory Version 4.0 (PedsQL 4.0) Generic Core Scales, the Chinese Version. 3493 school students aged 6-18 years were recruited using multistage cluster sampling method. Health-related quality of life was assessed using the above-mentioned PedsQL 4.0 scales. The internal consistency was assessed, using Cronbach's a coefficient, while its validity was tested through correlation analysis, t-test and exploratory factor analysis. The internal consistency reliability for Total Scale Score (Cronbach's alpha = 0.90), Physical Health Summary Score (alpha= 0.81), and Psychosocial Health Summary Score (alpha= 0.89) were excellent. Six major factors were extracted by factor analysis which basically matched the designed structure of the original version accounting for nearly 66% of the variance. The total Scale Score significantly decreased by 3.5 to 13.3 (P < 0.05) in children and adolescents who had diseases including cold, skin hypersensitiveness, food allergy, courbature or arthralgia, breathlessness with a frequency of 6 times or more per year or had asthma as compared to those with lower frequency (< or = 5 times/y) of the diseases or without asthma. We found moderate to high correlations between items and the subscales. Correlation coefficients ranged between 0.45 to 0.84 (P < 0.01). The reliability and validity of the parent proxy-report scales of PedsQL 4.0 Generic Core Scales of the Chinese Version were as good as the original version. Our findings suggested that the scales could be applied to evaluate the health-related quality of life in childhood children in similar Chinese regions to Guangzhou.

  3. Test-retest reliability of sit-to-stand and stand-to-sit analysis in people with and without chronic non-specific low back pain.

    PubMed

    Pourahmadi, Mohammad Reza; Ebrahimi Takamjani, Ismail; Jaberzadeh, Shapour; Sarrafzadeh, Javad; Sanjari, Mohammad Ali; Bagheri, Rasool; Jannati, Elham

    2018-06-01

    Sit-to-stand (STD) and stand-to-sit (SIT) analysis can provide information on functional independence in daily activities in patients with low back pain (LBP). However, in order for measurements to be clinically useful, data on psychometric properties should be available. The main purpose was to investigate intra-rater reliability of STD and SIT tasks in participants with and without chronic non-specific LBP (CNLBP). The second purpose was to detect any differences in lumbar spine and hips sagittal plane kinematics and coordination between asymptomatic individuals and CNLBP patients during STD and SIT. Cross-sectional study. Twenty-three CNLBP patients and 23 demographically-matched controls were recruited. Ten markers were placed on specific anatomical landmarks. Participants were asked to perform STD and SIT at a preferred speed. Peak flexion angles, mean angular velocities, lumbar to hip movement ratios, and relative phase angles were measured. The procedure was repeated after 2 h and 6-8 days. Differences between two groups were analyzed using independent t-test. Intraclass correlation coefficient (ICC 3,k), standard error of measurement (SEM), and limits of agreement (LOAs) were also estimated. The ICC values showed moderate to excellent intra-rater reliability, with relatively low SEM values (≤10.17°). The 95% LOAs demonstrated that there were no differences between the measured parameters. Furthermore, CNLBP patients had limited sagittal plane angles, smaller angular velocities, and lumbar-hip dis-coordination compared to asymptomatic participants. The results indicated moderate to excellent test-retest reliability of STD and SIT analysis. Moreover, CNLBP patients had altered kinematics during STD and its reverse. Copyright © 2017 Elsevier Ltd. All rights reserved.

  4. NASCOM network: Ground communications reliability report

    NASA Technical Reports Server (NTRS)

    1973-01-01

    A reliability performance analysis of the NASCOM Network circuits is reported. Network performance narrative summary is presented to include significant changes in circuit configurations, current figures, and trends in each trouble category with notable circuit totals specified. Lost time and interruption tables listing circuits which were affected by outages showing their totals category are submitted. A special analysis of circuits with low reliabilities is developed with tables depicting the performance and graphs for individual reliabilities.

  5. Theory of reliable systems. [systems analysis and design

    NASA Technical Reports Server (NTRS)

    Meyer, J. F.

    1973-01-01

    The analysis and design of reliable systems are discussed. The attributes of system reliability studied are fault tolerance, diagnosability, and reconfigurability. Objectives of the study include: to determine properties of system structure that are conducive to a particular attribute; to determine methods for obtaining reliable realizations of a given system; and to determine how properties of system behavior relate to the complexity of fault tolerant realizations. A list of 34 references is included.

  6. Rocket engine system reliability analyses using probabilistic and fuzzy logic techniques

    NASA Technical Reports Server (NTRS)

    Hardy, Terry L.; Rapp, Douglas C.

    1994-01-01

    The reliability of rocket engine systems was analyzed by using probabilistic and fuzzy logic techniques. Fault trees were developed for integrated modular engine (IME) and discrete engine systems, and then were used with the two techniques to quantify reliability. The IRRAS (Integrated Reliability and Risk Analysis System) computer code, developed for the U.S. Nuclear Regulatory Commission, was used for the probabilistic analyses, and FUZZYFTA (Fuzzy Fault Tree Analysis), a code developed at NASA Lewis Research Center, was used for the fuzzy logic analyses. Although both techniques provided estimates of the reliability of the IME and discrete systems, probabilistic techniques emphasized uncertainty resulting from randomness in the system whereas fuzzy logic techniques emphasized uncertainty resulting from vagueness in the system. Because uncertainty can have both random and vague components, both techniques were found to be useful tools in the analysis of rocket engine system reliability.

  7. Cross-cultural adaptation and validation of the Italian version of the Kerlan-Jobe Orthopaedic Clinic Shoulder and Elbow score.

    PubMed

    Merolla, Giovanni; Corona, Katia; Zanoli, Gustavo; Cerciello, Simone; Giannotti, Stefano; Porcellini, Giuseppe

    2017-12-01

    The Kerlan-Jobe Orthopaedic Clinic (KJOC) Shoulder and Elbow score is a reliable and sensitive tool to measure the performance of overhead athletes. The purpose of this study was to carry out a cross-cultural adaptation and validation of the KJOC questionnaire in Italian and to assess its reliability, validity, and responsiveness. Ninety professional athletes with a painful shoulder were included in this study and were assigned to the "injury group" (n = 32) or the "overuse group" (n = 58); 65 were managed conservatively and 25 were treated by arthroscopic surgery. To assess the reliability of the KJOC score, patients were asked to fill in the questionnaire at baseline and after 2 weeks. To test the construct validity, KJOC scores were compared to those obtained with the Italian version of the Disabilities of the Arm, Shoulder, and Hand (DASH) scale, and with the DASH sports/performing arts module. To test KJOC score responsiveness, the follow-up KJOC scores of the participants treated conservatively were compared to those of the patients treated by arthroscopic surgery. Statistical analysis demonstrated that the KJOC questionnaire is reliable in terms of the single items and the overall score (ICC 0.95-0.99); that it has high construct validity (r s  = -0.697; p < 0.01); and that it is responsive to clinical differences in shoulder function (p < 0.0001). The Italian version of the KJOC Shoulder and Elbow score performed in a similar way to the English version and demonstrated good validity, reliability, and responsiveness after conservative and surgical treatment. II.

  8. Agreement and reliability of pelvic floor measurements during contraction using three-dimensional pelvic floor ultrasound and virtual reality.

    PubMed

    Speksnijder, L; Rousian, M; Steegers, E A P; Van Der Spek, P J; Koning, A H J; Steensma, A B

    2012-07-01

    Virtual reality is a novel method of visualizing ultrasound data with the perception of depth and offers possibilities for measuring non-planar structures. The levator ani hiatus has both convex and concave aspects. The aim of this study was to compare levator ani hiatus volume measurements obtained with conventional three-dimensional (3D) ultrasound and with a virtual reality measurement technique and to establish their reliability and agreement. 100 symptomatic patients visiting a tertiary pelvic floor clinic with a normal intact levator ani muscle diagnosed on translabial ultrasound were selected. Datasets were analyzed using a rendered volume with a slice thickness of 1.5 cm at the level of minimal hiatal dimensions during contraction. The levator area (in cm(2)) was measured and multiplied by 1.5 to get the levator ani hiatus volume in conventional 3D ultrasound (in cm(3)). Levator ani hiatus volume measurements were then measured semi-automatically in virtual reality (cm(3) ) using a segmentation algorithm. An intra- and interobserver analysis of reliability and agreement was performed in 20 randomly chosen patients. The mean difference between levator ani hiatus volume measurements performed using conventional 3D ultrasound and virtual reality was 0.10 (95% CI, - 0.15 to 0.35) cm(3). The intraclass correlation coefficient (ICC) comparing conventional 3D ultrasound with virtual reality measurements was > 0.96. Intra- and interobserver ICCs for conventional 3D ultrasound measurements were > 0.94 and for virtual reality measurements were > 0.97, indicating good reliability for both. Levator ani hiatus volume measurements performed using virtual reality were reliable and the results were similar to those obtained with conventional 3D ultrasonography. Copyright © 2012 ISUOG. Published by John Wiley & Sons, Ltd.

  9. The development and validation of a test of science critical thinking for fifth graders.

    PubMed

    Mapeala, Ruslan; Siew, Nyet Moi

    2015-01-01

    The paper described the development and validation of the Test of Science Critical Thinking (TSCT) to measure the three critical thinking skill constructs: comparing and contrasting, sequencing, and identifying cause and effect. The initial TSCT consisted of 55 multiple choice test items, each of which required participants to select a correct response and a correct choice of critical thinking used for their response. Data were obtained from a purposive sampling of 30 fifth graders in a pilot study carried out in a primary school in Sabah, Malaysia. Students underwent the sessions of teaching and learning activities for 9 weeks using the Thinking Maps-aided Problem-Based Learning Module before they answered the TSCT test. Analyses were conducted to check on difficulty index (p) and discrimination index (d), internal consistency reliability, content validity, and face validity. Analysis of the test-retest reliability data was conducted separately for a group of fifth graders with similar ability. Findings of the pilot study showed that out of initial 55 administered items, only 30 items with relatively good difficulty index (p) ranged from 0.40 to 0.60 and with good discrimination index (d) ranged within 0.20-1.00 were selected. The Kuder-Richardson reliability value was found to be appropriate and relatively high with 0.70, 0.73 and 0.92 for identifying cause and effect, sequencing, and comparing and contrasting respectively. The content validity index obtained from three expert judgments equalled or exceeded 0.95. In addition, test-retest reliability showed good, statistically significant correlations ([Formula: see text]). From the above results, the selected 30-item TSCT was found to have sufficient reliability and validity and would therefore represent a useful tool for measuring critical thinking ability among fifth graders in primary science.

  10. Reliability analysis of visual ranking of coronary artery calcification on low-dose CT of the thorax for lung cancer screening: comparison with ECG-gated calcium scoring CT.

    PubMed

    Kim, Yoon Kyung; Sung, Yon Mi; Cho, So Hyun; Park, Young Nam; Choi, Hye-Young

    2014-12-01

    Coronary artery calcification (CAC) is frequently detected on low-dose CT (LDCT) of the thorax. Concurrent assessment of CAC and lung cancer screening using LDCT is beneficial in terms of cost and radiation dose reduction. The aim of our study was to evaluate the reliability of visual ranking of positive CAC on LDCT compared to Agatston score (AS) on electrocardiogram (ECG)-gated calcium scoring CT. We studied 576 patients who were consecutively registered for health screening and undergoing both LDCT and ECG-gated calcium scoring CT. We excluded subjects with an AS of zero. The final study cohort included 117 patients with CAC (97 men; mean age, 53.4 ± 8.5). AS was used as the gold standard (mean score 166.0; range 0.4-3,719.3). Two board-certified radiologists and two radiology residents participated in an observer performance study. Visual ranking of CAC was performed according to four categories (1-10, 11-100, 101-400, and 401 or higher) for coronary artery disease risk stratification. Weighted kappa statistics were used to measure the degree of reliability on visual ranking of CAC on LDCT. The degree of reliability on visual ranking of CAC on LDCT compared to ECG-gated calcium scoring CT was excellent for board-certified radiologists and good for radiology residents. A high degree of association was observed with 71.6% of visual rankings in the same category as the Agatston category and 98.9% varying by no more than one category. Visual ranking of positive CAC on LDCT is reliable for predicting AS rank categorization.

  11. Validity and intra-rater reliability of MyJump app on iPhone 6s in jump performance.

    PubMed

    Stanton, Robert; Wintour, Sally-Anne; Kean, Crystal O

    2017-05-01

    Smartphone applications are increasingly used by researchers, coaches, athletes and clinicians. The aim of this study was to examine the concurrent validity and intra-rater reliability of the smartphone-based application, MyJump, against laboratory-based force plate measurements. Cross sectional study. Participants completed counter-movement jumps (CMJ) (n=29) and 30cm drop jumps (DJ) (n=27) on a force plate which were simultaneously recorded using MyJump. To assess concurrent validity, jump height, derived from flight time acquired from each device, was compared for each jump type. Intra-rater reliability was determined by replicating data analysis of MyJump recordings on two occasions separated by seven days. CMJ and DJ heights derived from MyJump showed excellent agreement with the force plate (ICC values range from 0.991 for CMJ to 0.993) However mean DJ height from the force plate was significantly higher than MyJump (mean difference: 0.87cm, 95% CI: 0.69-1.04cm). Intra-rater reliability of MyJump for both CMJ and DJ was almost perfect (ICC values range from 0.997 for CMJ to 0.998 for DJ); however, mean CMJ and DJ jump height for Day 1 was significantly higher than Day 2 (CMJ: 0.43cm, 95% CI: 0.23-0.62cm); (DJ: 0.38cm, 95% CI: 0.23-0.53cm). The present study finds MyJump to be a valid and highly reliable tool for researchers, coaches, athletes and clinicians; however, systematic bias should be considered when comparing MyJump outputs to other testing devices. Copyright © 2016 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  12. Validity and reliability of the Paprosky acetabular defect classification.

    PubMed

    Yu, Raymond; Hofstaetter, Jochen G; Sullivan, Thomas; Costi, Kerry; Howie, Donald W; Solomon, Lucian B

    2013-07-01

    The Paprosky acetabular defect classification is widely used but has not been appropriately validated. Reliability of the Paprosky system has not been evaluated in combination with standardized techniques of measurement and scoring. This study evaluated the reliability, teachability, and validity of the Paprosky acetabular defect classification. Preoperative radiographs from a random sample of 83 patients undergoing 85 acetabular revisions were classified by four observers, and their classifications were compared with quantitative intraoperative measurements. Teachability of the classification scheme was tested by dividing the four observers into two groups. The observers in Group 1 underwent three teaching sessions; those in Group 2 underwent one session and the influence of teaching on the accuracy of their classifications was ascertained. Radiographic evaluation showed statistically significant relationships with intraoperative measurements of anterior, medial, and superior acetabular defect sizes. Interobserver reliability improved substantially after teaching and did not improve without it. The weighted kappa coefficient went from 0.56 at Occasion 1 to 0.79 after three teaching sessions in Group 1 observers, and from 0.49 to 0.65 after one teaching session in Group 2 observers. The Paprosky system is valid and shows good reliability when combined with standardized definitions of radiographic landmarks and a structured analysis. Level II, diagnostic study. See the Guidelines for Authors for a complete description of levels of evidence.

  13. Uncertainty quantification and reliability assessment in operational oil spill forecast modeling system.

    PubMed

    Hou, Xianlong; Hodges, Ben R; Feng, Dongyu; Liu, Qixiao

    2017-03-15

    As oil transport increasing in the Texas bays, greater risks of ship collisions will become a challenge, yielding oil spill accidents as a consequence. To minimize the ecological damage and optimize rapid response, emergency managers need to be informed with how fast and where oil will spread as soon as possible after a spill. The state-of-the-art operational oil spill forecast modeling system improves the oil spill response into a new stage. However uncertainty due to predicted data inputs often elicits compromise on the reliability of the forecast result, leading to misdirection in contingency planning. Thus understanding the forecast uncertainty and reliability become significant. In this paper, Monte Carlo simulation is implemented to provide parameters to generate forecast probability maps. The oil spill forecast uncertainty is thus quantified by comparing the forecast probability map and the associated hindcast simulation. A HyosPy-based simple statistic model is developed to assess the reliability of an oil spill forecast in term of belief degree. The technologies developed in this study create a prototype for uncertainty and reliability analysis in numerical oil spill forecast modeling system, providing emergency managers to improve the capability of real time operational oil spill response and impact assessment. Copyright © 2017 Elsevier Ltd. All rights reserved.

  14. Effects of imperfect automation on decision making in a simulated command and control task.

    PubMed

    Rovira, Ericka; McGarry, Kathleen; Parasuraman, Raja

    2007-02-01

    Effects of four types of automation support and two levels of automation reliability were examined. The objective was to examine the differential impact of information and decision automation and to investigate the costs of automation unreliability. Research has shown that imperfect automation can lead to differential effects of stages and levels of automation on human performance. Eighteen participants performed a "sensor to shooter" targeting simulation of command and control. Dependent variables included accuracy and response time of target engagement decisions, secondary task performance, and subjective ratings of mental work-load, trust, and self-confidence. Compared with manual performance, reliable automation significantly reduced decision times. Unreliable automation led to greater cost in decision-making accuracy under the higher automation reliability condition for three different forms of decision automation relative to information automation. At low automation reliability, however, there was a cost in performance for both information and decision automation. The results are consistent with a model of human-automation interaction that requires evaluation of the different stages of information processing to which automation support can be applied. If fully reliable decision automation cannot be guaranteed, designers should provide users with information automation support or other tools that allow for inspection and analysis of raw data.

  15. Fiber Access Networks: Reliability Analysis and Swedish Broadband Market

    NASA Astrophysics Data System (ADS)

    Wosinska, Lena; Chen, Jiajia; Larsen, Claus Popp

    Fiber access network architectures such as active optical networks (AONs) and passive optical networks (PONs) have been developed to support the growing bandwidth demand. Whereas particularly Swedish operators prefer AON, this may not be the case for operators in other countries. The choice depends on a combination of technical requirements, practical constraints, business models, and cost. Due to the increasing importance of reliable access to the network services, connection availability is becoming one of the most crucial issues for access networks, which should be reflected in the network owner's architecture decision. In many cases protection against failures is realized by adding backup resources. However, there is a trade off between the cost of protection and the level of service reliability since improving reliability performance by duplication of network resources (and capital expenditures CAPEX) may be too expensive. In this paper we present the evolution of fiber access networks and compare reliability performance in relation to investment and management cost for some representative cases. We consider both standard and novel architectures for deployment in both sparsely and densely populated areas. While some recent works focused on PON protection schemes with reduced CAPEX the current and future effort should be put on minimizing the operational expenditures (OPEX) during the access network lifetime.

  16. Reliability analysis method of a solar array by using fault tree analysis and fuzzy reasoning Petri net

    NASA Astrophysics Data System (ADS)

    Wu, Jianing; Yan, Shaoze; Xie, Liyang

    2011-12-01

    To address the impact of solar array anomalies, it is important to perform analysis of the solar array reliability. This paper establishes the fault tree analysis (FTA) and fuzzy reasoning Petri net (FRPN) models of a solar array mechanical system and analyzes reliability to find mechanisms of the solar array fault. The index final truth degree (FTD) and cosine matching function (CMF) are employed to resolve the issue of how to evaluate the importance and influence of different faults. So an improvement reliability analysis method is developed by means of the sorting of FTD and CMF. An example is analyzed using the proposed method. The analysis results show that harsh thermal environment and impact caused by particles in space are the most vital causes of the solar array fault. Furthermore, other fault modes and the corresponding improvement methods are discussed. The results reported in this paper could be useful for the spacecraft designers, particularly, in the process of redesigning the solar array and scheduling its reliability growth plan.

  17. Probabilistic Structural Analysis of the Solid Rocket Booster Aft Skirt External Fitting Modification

    NASA Technical Reports Server (NTRS)

    Townsend, John S.; Peck, Jeff; Ayala, Samuel

    2000-01-01

    NASA has funded several major programs (the Probabilistic Structural Analysis Methods Project is an example) to develop probabilistic structural analysis methods and tools for engineers to apply in the design and assessment of aerospace hardware. A probabilistic finite element software code, known as Numerical Evaluation of Stochastic Structures Under Stress, is used to determine the reliability of a critical weld of the Space Shuttle solid rocket booster aft skirt. An external bracket modification to the aft skirt provides a comparison basis for examining the details of the probabilistic analysis and its contributions to the design process. Also, analysis findings are compared with measured Space Shuttle flight data.

  18. Emotional and tangible social support in a German population-based sample: Development and validation of the Brief Social Support Scale (BS6).

    PubMed

    Beutel, Manfred E; Brähler, Elmar; Wiltink, Jörg; Michal, Matthias; Klein, Eva M; Jünger, Claus; Wild, Philipp S; Münzel, Thomas; Blettner, Maria; Lackner, Karl; Nickels, Stefan; Tibubos, Ana N

    2017-01-01

    Aim of the study was the development and validation of the psychometric properties of a six-item bi-factorial instrument for the assessment of social support (emotional and tangible support) with a population-based sample. A cross-sectional data set of N = 15,010 participants enrolled in the Gutenberg Health Study (GHS) in 2007-2012 was divided in two sub-samples. The GHS is a population-based, prospective, observational single-center cohort study in the Rhein-Main-Region in western Mid-Germany. The first sub-sample was used for scale development by performing an exploratory factor analysis. In order to test construct validity, confirmatory factor analyses were run to compare the extracted bi-factorial model with the one-factor solution. Reliability of the scales was indicated by calculating internal consistency. External validity was tested by investigating demographic characteristics health behavior, and distress using analysis of variance, Spearman and Pearson correlation analysis, and logistic regression analysis. Based on an exploratory factor analysis, a set of six items was extracted representing two independent factors. The two-factor structure of the Brief Social Support Scale (BS6) was confirmed by the results of the confirmatory factor analyses. Fit indices of the bi-factorial model were good and better compared to the one-factor solution. External validity was demonstrated for the BS6. The BS6 is a reliable and valid short scale that can be applied in social surveys due to its brevity to assess emotional and practical dimensions of social support.

  19. Validity and reliability of a new tool to evaluate handwriting difficulties in Parkinson's disease.

    PubMed

    Nackaerts, Evelien; Heremans, Elke; Smits-Engelsman, Bouwien C M; Broeder, Sanne; Vandenberghe, Wim; Bergmans, Bruno; Nieuwboer, Alice

    2017-01-01

    Handwriting in Parkinson's disease (PD) features specific abnormalities which are difficult to assess in clinical practice since no specific tool for evaluation of spontaneous movement is currently available. This study aims to validate the 'Systematic Screening of Handwriting Difficulties' (SOS-test) in patients with PD. Handwriting performance of 87 patients and 26 healthy age-matched controls was examined using the SOS-test. Sixty-seven patients were tested a second time within a period of one month. Participants were asked to copy as much as possible of a text within 5 minutes with the instruction to write as neatly and quickly as in daily life. Writing speed (letters in 5 minutes), size (mm) and quality of handwriting were compared. Correlation analysis was performed between SOS outcomes and other fine motor skill measurements and disease characteristics. Intrarater, interrater and test-retest reliability were assessed using the intraclass correlation coefficient (ICC) and Spearman correlation coefficient. Patients with PD had a smaller (p = 0.043) and slower (p<0.001) handwriting and showed worse writing quality (p = 0.031) compared to controls. The outcomes of the SOS-test significantly correlated with fine motor skill performance and disease duration and severity. Furthermore, the test showed excellent intrarater, interrater and test-retest reliability (ICC > 0.769 for both groups). The SOS-test is a short and effective tool to detect handwriting problems in PD with excellent reliability. It can therefore be recommended as a clinical instrument for standardized screening of handwriting deficits in PD.

  20. Concurrent validity and reliability of torso-worn inertial measurement unit for jump power and height estimation.

    PubMed

    Rantalainen, Timo; Gastin, Paul B; Spangler, Rhys; Wundersitz, Daniel

    2018-09-01

    The purpose of the present study was to evaluate the concurrent validity and test-retest repeatability of torso-worn IMU-derived power and jump height in a counter-movement jump test. Twenty-seven healthy recreationally active males (age, 21.9 [SD 2.0] y, height, 1.76 [0.7] m, mass, 73.7 [10.3] kg) wore an IMU and completed three counter-movement jumps a week apart. A force platform and a 3D motion analysis system were used to concurrently measure the jumps and subsequently derive power and jump height (based on take-off velocity and flight time). The IMU significantly overestimated power (mean difference = 7.3 W/kg; P < 0.001) compared to force-platform-derived power but good correspondence between methods was observed (Intra-class correlation coefficient [ICC] = 0.69). IMU-derived power exhibited good reliability (ICC = 0.67). Velocity-derived jump heights exhibited poorer concurrent validity (ICC = 0.72 to 0.78) and repeatability (ICC = 0.68) than flight-time-derived jump heights, which exhibited excellent validity (ICC = 0.93 to 0.96) and reliability (ICC = 0.91). Since jump height and power are closely related, and flight-time-derived jump height exhibits excellent concurrent validity and reliability, flight-time-derived jump height could provide a more desirable measure compared to power when assessing athletic performance in a counter-movement jump with IMUs.

Top