Sample records for reliability minimal detectable

  1. The reliability, accuracy and minimal detectable difference of a multi-segment kinematic model of the foot-shoe complex.

    PubMed

    Bishop, Chris; Paul, Gunther; Thewlis, Dominic

    2013-04-01

    Kinematic models are commonly used to quantify foot and ankle kinematics, yet no marker sets or models have been proven reliable or accurate when wearing shoes. Further, the minimal detectable difference of a developed model is often not reported. We present a kinematic model that is reliable, accurate and sensitive to describe the kinematics of the foot-shoe complex and lower leg during walking gait. In order to achieve this, a new marker set was established, consisting of 25 markers applied on the shoe and skin surface, which informed a four segment kinematic model of the foot-shoe complex and lower leg. Three independent experiments were conducted to determine the reliability, accuracy and minimal detectable difference of the marker set and model. Inter-rater reliability of marker placement on the shoe was proven to be good to excellent (ICC=0.75-0.98) indicating that markers could be applied reliably between raters. Intra-rater reliability was better for the experienced rater (ICC=0.68-0.99) than the inexperienced rater (ICC=0.38-0.97). The accuracy of marker placement along each axis was <6.7 mm for all markers studied. Minimal detectable difference (MDD90) thresholds were defined for each joint; tibiocalcaneal joint--MDD90=2.17-9.36°, tarsometatarsal joint--MDD90=1.03-9.29° and the metatarsophalangeal joint--MDD90=1.75-9.12°. These thresholds proposed are specific for the description of shod motion, and can be used in future research designed at comparing between different footwear. Copyright © 2012 Elsevier B.V. All rights reserved.

  2. Reliability and Validity of the Evidence-Based Practice Confidence (EPIC) Scale

    ERIC Educational Resources Information Center

    Salbach, Nancy M.; Jaglal, Susan B.; Williams, Jack I.

    2013-01-01

    Introduction: The reliability, minimal detectable change (MDC), and construct validity of the evidence-based practice confidence (EPIC) scale were evaluated among physical therapists (PTs) in clinical practice. Methods: A longitudinal mail survey was conducted. Internal consistency and test-retest reliability were estimated using Cronbach's alpha…

  3. Optimal Sensor Location Design for Reliable Fault Detection in Presence of False Alarms

    PubMed Central

    Yang, Fan; Xiao, Deyun; Shah, Sirish L.

    2009-01-01

    To improve fault detection reliability, sensor location should be designed according to an optimization criterion with constraints imposed by issues of detectability and identifiability. Reliability requires the minimization of undetectability and false alarm probability due to random factors on sensor readings, which is not only related with sensor readings but also affected by fault propagation. This paper introduces the reliability criteria expression based on the missed/false alarm probability of each sensor and system topology or connectivity derived from the directed graph. The algorithm for the optimization problem is presented as a heuristic procedure. Finally, a boiler system is illustrated using the proposed method. PMID:22291524

  4. Reliability and validity of the de Morton Mobility Index in individuals with sub-acute stroke.

    PubMed

    Braun, Tobias; Marks, Detlef; Thiel, Christian; Grüneberg, Christian

    2018-02-04

    To establish the validity and reliability of the de Morton Mobility Index (DEMMI) in patients with sub-acute stroke. This cross-sectional study was performed in a neurological rehabilitation hospital. We assessed unidimensionality, construct validity, internal consistency reliability, inter-rater reliability, minimal detectable change and possible floor and ceiling effects of the DEMMI in adult patients with sub-acute stroke. The study included a total sample of 121 patients with sub-acute stroke. We analysed validity (n = 109) and reliability (n = 51) in two sub-samples. Rasch analysis indicated unidimensionality with an overall fit to the model (chi-square = 12.37, p = 0.577). All hypotheses on construct validity were confirmed. Internal consistency reliability (Cronbach's alpha = 0.94) and inter-rater reliability (intraclass correlation coefficient = 0.95; 95% confidence interval: 0.92-0.97) were excellent. The minimal detectable change with 90% confidence was 13 points. No floor or ceiling effects were evident. These results indicate unidimensionality, sufficient internal consistency reliability, inter-rater reliability, and construct validity of the DEMMI in patients with a sub-acute stroke. Advantages of the DEMMI in clinical application are the short administration time, no need for special equipment and interval level data. The de Morton Mobility Index, therefore, may be a useful performance-based bedside test to measure mobility in individuals with a sub-acute stroke across the whole mobility spectrum. Implications for Rehabilitation The de Morton Mobility Index (DEMMI) is an unidimensional measurement instrument of mobility in individuals with sub-acute stroke. The DEMMI has excellent internal consistency and inter-rater reliability, and sufficient construct validity. The minimal detectable change of the DEMMI with 90% confidence in stroke rehabilitation is 13 points. The lack of any floor or ceiling effects on hospital admission indicates applicability across the whole mobility spectrum of patients with sub-acute stroke.

  5. Reliability, minimal detectable change and responsiveness to change: Indicators to select the best method to measure sedentary behaviour in older adults in different study designs.

    PubMed

    Dontje, Manon L; Dall, Philippa M; Skelton, Dawn A; Gill, Jason M R; Chastin, Sebastien F M

    2018-01-01

    Prolonged sedentary behaviour (SB) is associated with poor health. It is unclear which SB measure is most appropriate for interventions and population surveillance to measure and interpret change in behaviour in older adults. The aims of this study: to examine the relative and absolute reliability, Minimal Detectable Change (MDC) and responsiveness to change of subjective and objective methods of measuring SB in older adults and give recommendations of use for different study designs. SB of 18 older adults (aged 71 (IQR 7) years) was assessed using a systematic set of six subjective tools, derived from the TAxonomy of Self report Sedentary behaviour Tools (TASST), and one objective tool (activPAL3c), over 14 days. Relative reliability (Intra Class Correlation coefficients-ICC), absolute reliability (SEM), MDC, and the relative responsiveness (Cohen's d effect size (ES) and Guyatt's Responsiveness coefficient (GR)) were calculated for each of the different tools and ranked for different study designs. ICC ranged from 0.414 to 0.946, SEM from 36.03 to 137.01 min, MDC from 1.66 to 8.42 hours, ES from 0.017 to 0.259 and GR from 0.024 to 0.485. Objective average day per week measurement ranked as most responsive in a clinical practice setting, whereas a one day measurement ranked highest in quasi-experimental, longitudinal and controlled trial study designs. TV viewing-Previous Week Recall (PWR) ranked as most responsive subjective measure in all study designs. The reliability, Minimal Detectable Change and responsiveness to change of subjective and objective methods of measuring SB is context dependent. Although TV viewing-PWR is the more reliable and responsive subjective method in most situations, it may have limitations as a reliable measure of total SB. Results of this study can be used to guide choice of tools for detecting change in sedentary behaviour in older adults in the contexts of population surveillance, intervention evaluation and individual care.

  6. Droplet Digital PCR for Minimal Residual Disease Detection in Mature Lymphoproliferative Disorders.

    PubMed

    Drandi, Daniela; Ferrero, Simone; Ladetto, Marco

    2018-01-01

    Minimal residual disease (MRD) detection has a powerful prognostic relevance for response evaluation and prediction of relapse in hematological malignancies. Real-time quantitative PCR (qPCR) has become the settled and standardized method for MRD assessment in lymphoid disorders. However, qPCR is a relative quantification approach, since it requires a reference standard curve. Droplet digital TM PCR (ddPCR TM ) allows a reliable absolute tumor burden quantification withdrawing the need for preparing, for each experiment, a tumor-specific standard curve. We have recently shown that ddPCR has a good concordance with qPCR and could be a feasible and reliable tool for MRD monitoring in mature lymphoproliferative disorders. In this chapter we describe the experimental workflow, from the detection of the clonal molecular marker to the MRD monitoring by ddPCR, in patients affected by multiple myeloma, mantle cell lymphoma and follicular lymphoma. However, standardization programs among different laboratories are needed in order to ensure the reliability and reproducibility of ddPCR-based MRD results.

  7. The reliability, minimal detectable change and concurrent validity of a gravity-based bubble inclinometer and iphone application for measuring standing lumbar lordosis.

    PubMed

    Salamh, Paul A; Kolber, Morey

    2014-01-01

    To investigate the reliability, minimal detectable change (MDC90) and concurrent validity of a gravity-based bubble inclinometer (inclinometer) and iPhone® application for measuring standing lumbar lordosis. Two investigators used both an inclinometer and an iPhone® with an inclinometer application to measure lumbar lordosis of 30 asymptomatic participants. ICC models 3,k and 2,k were used for the intrarater and interrater analysis, respectively. Good interrater and intrarater reliability was present for the inclinometer with Intraclass Correlation Coefficients (ICC) of 0.90 and 0.85, respectively and the iPhone® application with ICC values of 0.96 and 0.81. The minimal detectable change (MDC90) indicates that a change greater than or equal to 7° and 6° is needed to exceed the threshold of error using the iPhone® and inclinometer, respectively. The concurrent validity between the two instruments was good with a Pearson product-moment coefficient of correlation (r) of 0.86 for both raters. Ninety-five percent limits of agreement identified differences ranging from 9° greater in regards to the iPhone® to 8° less regarding the inclinometer. Both the inclinometer and iPhone® application possess good interrater reliability, intrarater reliability and concurrent validity for measuring standing lumbar lordosis. This investigation provides preliminary evidence to suggest that smart phone applications may offer clinical utility comparable to inclinometry for quantifying standing lumbar lordosis. Clinicians should recognize potential individual differences when using these devices interchangeably.

  8. Reliability and diagnostic characteristics of the JFK coma recovery scale-revised: exploring the influence of rater's level of experience.

    PubMed

    Løvstad, Marianne; Frøslie, Kathrine F; Giacino, Joseph T; Skandsen, Toril; Anke, Audny; Schanke, Anne-Kristine

    2010-01-01

    To confirm the reliability and diagnostic validity of the JFK Coma Recovery Scale-Revised (CRS-R) across raters with varying levels of experience. Thirty-one patients with disorders of consciousness were recruited from 6 Norwegian hospitals. CRS-R and the Disability Rating Scale. Reliability measures were good for the CRS-R total scores and moderate to good for its subscales. Diagnostic agreement among examiners was good. Raters' experience with the CRS-R favorably influenced reliability. Sensitivity and specificity analyses demonstrated better detection of patients in minimally conscious state on the CRS-R relative to the Disability Rating Scale. The CRS-R is a reliable tool for diagnosing vegetative state and minimally conscious state. Raters' level of experience influences the reliability of the CRS-R scores.

  9. Using generalizability theory to develop clinical assessment protocols.

    PubMed

    Preuss, Richard A

    2013-04-01

    Clinical assessment protocols must produce data that are reliable, with a clinically attainable minimal detectable change (MDC). In a reliability study, generalizability theory has 2 advantages over classical test theory. These advantages provide information that allows assessment protocols to be adjusted to match individual patient profiles. First, generalizability theory allows the user to simultaneously consider multiple sources of measurement error variance (facets). Second, it allows the user to generalize the findings of the main study across the different study facets and to recalculate the reliability and MDC based on different combinations of facet conditions. In doing so, clinical assessment protocols can be chosen based on minimizing the number of measures that must be taken to achieve a realistic MDC, using repeated measures to minimize the MDC, or simply based on the combination that best allows the clinician to monitor an individual patient's progress over a specified period of time.

  10. Ultrasound measures of supraspinatus tendon thickness and acromiohumeral distance in rotator cuff tendinopathy are reliable.

    PubMed

    McCreesh, Karen M; Anjum, Shakeel; Crotty, James M; Lewis, Jeremy S

    2016-01-01

    Rotator cuff (RC) tendinopathy has been widely ascribed to impingement of the supraspinatus tendon (SsT) in the subacromial space, measured as the acromiohumeral distance (AHD). Ultrasound (US) is suitable for measuring AHD and SsT thickness, but few reliability studies have been carried out in symptomatic populations, and interrater reliability is unconfirmed. This study aimed to examine the intrarater and interrater reliability of US measurements of AHD and SsT thickness in asymptomatic control subjects and patients with RC tendinopathy. Seventy participants were recruited and grouped as healthy controls (n = 25) and RC tendinopathy (n = 45). Repeated US measurements of AHD and SsT thickness were obtained by one rater in both groups and by two raters in the RC tendinopathy group. Intrarater and interrater reliability coefficients were excellent for both measurements (intraclass correlation > 0.92), but the intrarater reliability was superior. The minimal detectable change values in the symptomatic group were 0.7 mm for AHD and 0.6 mm for SsT thickness for a single experienced examiner; the values rose to 1.2 mm and 1.3 mm, respectively, for the pair of examiners. The results support the reliability of US for the measurement of AHD and SsT thickness in patients with symptomatic RC tendinopathy and provide minimal detectable change values for use in future research studies. © 2015 Wiley Periodicals, Inc.

  11. Study of fail-safe abort system for an actively cooled hypersonic aircraft, volume 2

    NASA Technical Reports Server (NTRS)

    Peeples, M. E.; Herring, R. L.

    1976-01-01

    Conceptual designs of a fail-safe abort system for hydrogen fueled actively cooled high speed aircraft are examined. The fail-safe concept depends on basically three factors: (1) a reliable method of detecting a failure or malfunction in the active cooling system, (2) the optimization of abort trajectories which minimize the descent heat load to the aircraft, and (3) fail-safe thermostructural concepts to minimize both the weight and the maximum temperature the structure will reach during descent. These factors are examined and promising approaches are evaluated based on weight, reliability, ease of manufacture and cost.

  12. Reliability, Validity, and Minimal Detectable Change of Four-Step Stair Climb Power Test in Community-Dwelling Older Adults.

    PubMed

    Ni, Meng; Brown, Lorna G; Lawler, Danielle; Bean, Jonathan F

    2017-07-01

    Stair climb power is an important clinical measure of lower-extremity power. The stair climb power test (SCPT) was validated by requiring individuals to climb a full flight of stairs. A 4-step SCPT (4SCPT) would be more clinically feasible and easier to perform, yet its reliability and validity are unknown. To evaluate reliability, validity, and minimal detectable change of 4SCPT among community-dwelling older adults. This study is a cross-sectional analysis of baseline data from a clinical trial. Fifty older adults ≥65 years of age, at risk for mobility decline, consented to participate in this ancillary study. Test-retest reliability was derived from 2 measurements within each participant measured by a single assessor. Pearson correlation analyses among leg power measures (4SCPT, SCPT, single leg press power at 40% and 70% of the 1-repetition maximum [SLP40, SLP70]) were performed. Separate multivariate linear regressions were conducted evaluating the associations between each leg power measure and 2 mobility outcomes, the Short Physical Performance Battery (SPPB) and habitual gait speed (HGS). Minimal detectable change was based on a 90% confidence interval (MDC 90 ). The 4SCPT had excellent test-retest reliability (ICC(2,1) = 0.951), and strong correlation with SCPT, SLP40, and SLP70 ( r = 0.85-0.96). The 4SCPT explained a greater amount of variance in the SPPB (R 2 = 0.31) than other leg power measurements (R 2 = 0.23-0.25). The 4SCPT (R 2 = 0.41) and SCPT (R 2 = 0.42) described equivalent amounts of variance in HGS, and greater than that with SLP40 (R 2 = 0.28) and SLP70 (R 2 = 0.30). The MDC 90 for 4SCPT was 44.0 watts. This was a cross-sectional analysis within a small, nonrepresentative sample. Interrater reliability was not evaluated. The 4SCPT shows scientific promise as a valid and reliable leg power measurement among community-dwelling older adults. © 2017 American Physical Therapy Association

  13. Assessment of reliability, validity, responsiveness and minimally important change of the German Hip dysfunction and osteoarthritis outcome score (HOOS) in patients with osteoarthritis of the hip.

    PubMed

    Arbab, Dariusch; van Ochten, Johannes H M; Schnurr, Christoph; Bouillon, Bertil; König, Dietmar

    2017-12-01

    Patient-reported outcome measures are a critical tool in evaluating the efficacy of orthopedic procedures. The intention of this study was to evaluate reliability, validity, responsiveness and minimally important change of the German version of the Hip dysfunction and osteoarthritis outcome score (HOOS). The German HOOS was investigated in 251 consecutive patients before and 6 months after total hip arthroplasty. All patients completed HOOS, Oxford-Hip Score, Short-Form (SF-36) and numeric scales for pain and disability. Test-retest reliability, internal consistency, floor and ceiling effects, construct validity and minimal important change were analyzed. The German HOOS demonstrated excellent test-retest reliability with intraclass correlation coefficient values > 0.7. Cronbach´s alpha values demonstrated strong internal consistency. As hypothesized, HOOS subscales strongly correlated with corresponding OHS and SF-36 domains. All subscales showed excellent (effect size/standardized response means > 0.8) responsiveness between preoperative assessment and postoperative follow-up. The HOOS and all subdomains showed higher changes than the minimal detectable change which indicates true changes. The German version of the HOOS demonstrated good psychometric properties. It proved to be valid, reliable and responsive to the changes instrument for use in patients with hip osteoarthritis undergoing total hip replacement.

  14. Evaluative measurement properties of the patient-specific functional scale for primary shoulder complaints in physical therapy practice.

    PubMed

    Koehorst, Marije L S; van Trijffel, Emiel; Lindeboom, Robert

    2014-08-01

    Clinical measurement, longitudinal. To assess the test-retest reliability, construct validity, and responsiveness of the Patient-Specific Functional Scale (PSFS) in patients with a primary shoulder complaint. Health measurement outcomes have become increasingly important for evaluating treatment. Patient-specific questionnaires are useful tools for determining treatment goals and evaluating treatment in individual patients. These questionnaires have not yet been validated in patients with nonspecific shoulder pain. Patients completed the PSFS, the numeric pain rating scale, and the Shoulder Pain and Disability Index at baseline, and after 1 week and 4 to 6 weeks. Test-retest reliability was determined using intraclass correlation coefficients. To assess convergent validity, change scores of the PSFS were correlated with the numeric pain rating scale and Shoulder Pain and Disability Index change scores. Responsiveness was assessed by calculating the area under the curve, the minimal clinically important change, and minimal detectable change, using the global rating of change as an external criterion. Fifty patients (37 men; mean age, 47.7 years) participated in the study. Reliability was high (intraclass correlation coefficient = 0.87; 95% confidence interval [CI]: 0.72, 0.94). The correlations between the change scores of the PSFS and those of the Shoulder Pain and Disability Index and numeric pain rating scale were 0.45 (95% CI: 0.17, 0.80) and 0.55 (95% CI: 0.29, 0.73), respectively. The area under the curve for the PSFS was 0.67 (95% CI: 0.51, 0.83). The minimal detectable change and minimal clinically important change were 0.97 and 1.29 points, respectively. These results suggest that the PSFS is a reliable, valid, and responsive instrument that can be used as an evaluative instrument in patients with a primary shoulder complaint.

  15. Comparison of Two Methods for Estimating Adjustable One-Point Cane Length in Community-Dwelling Older Adults.

    PubMed

    Camara, Camila Thais Pinto; de Freitas, Sandra Maria Sbeghen Ferreira; de Lima, Waléria Paixão; Lima, Camila Astolphi; Amorim, César Ferreira; Perracini, Monica Rodrigues

    2017-01-01

    Our aim is to estimate inter-observer reliability, test-retest reliability, anthropometric and biomechanical adequacy and minimal detectable change when measuring the length of single-point adjustable canes in community-dwelling older adults. There are 112 participants in the study. They are men and women, aged 60 years and over, who were attending an outpatient community health centre. An exploratory study design was used. Participants underwent two assessments within the same day by two independent observers and by the same observer at an interval of 15-45 days. Two measures were used to establish the length of a single-point adjustable cane: the distance from the distal wrist crease to the floor (WF) and the distance from the top of the greater trochanter of the femur to the floor (TF). Each individual was fitted according to these two measures, and elbow flexion angle was measured. Inter-observer reliability and the test-retest reliability were high in both TF (ICC 3.1  = 0.918 and ICC 2.1  = 0.935) and WF measures (ICC 3.1  = 0.967 and ICC 2.1  = 0.960). Only 1% of the individuals kept an elbow flexion angle within the standard recommendation of 30° ± 10° when the cane length was determined by the TF measure, and 30% of the participants when the cane was determined by the WF measure. The minimal detectable cane length change was 2.2 cm. Our results suggest that, even though both measures are reliable, cane length determined by WF distance is more appropriate to keep the elbow flexion angle within the standard recommendation. The minimal detectable change corresponds to approximately a hole in the cane adjustment. Copyright © 2015 John Wiley & Sons, Ltd. Copyright © 2015 John Wiley & Sons, Ltd.

  16. Study of a fail-safe abort system for an actively cooled hypersonic aircraft. Volume 1: Technical summary

    NASA Technical Reports Server (NTRS)

    Pirello, C. J.; Herring, R. L.

    1976-01-01

    Conceptual designs of a fail-safe abort system for hydrogen fueled actively cooled high speed aircraft are examined. The fail-safe concept depends on basically three factors: (1) a reliable method of detecting a failure or malfunction in the active cooling system, (2) the optimization of abort trajectories which minimize the descent heat load to the aircraft, and (3) fail-safe thermostructural concepts to minimize both the weight and the maximum temperature the structure will reach during descent. These factors are examined and promising approaches are evaluated based on weight, reliability, ease of manufacture and cost.

  17. Sideband Algorithm for Automatic Wind Turbine Gearbox Fault Detection and Diagnosis: Preprint

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zappala, D.; Tavner, P.; Crabtree, C.

    2013-01-01

    Improving the availability of wind turbines (WT) is critical to minimize the cost of wind energy, especially for offshore installations. As gearbox downtime has a significant impact on WT availabilities, the development of reliable and cost-effective gearbox condition monitoring systems (CMS) is of great concern to the wind industry. Timely detection and diagnosis of developing gear defects within a gearbox is an essential part of minimizing unplanned downtime of wind turbines. Monitoring signals from WT gearboxes are highly non-stationary as turbine load and speed vary continuously with time. Time-consuming and costly manual handling of large amounts of monitoring data representmore » one of the main limitations of most current CMSs, so automated algorithms are required. This paper presents a fault detection algorithm for incorporation into a commercial CMS for automatic gear fault detection and diagnosis. The algorithm allowed the assessment of gear fault severity by tracking progressive tooth gear damage during variable speed and load operating conditions of the test rig. Results show that the proposed technique proves efficient and reliable for detecting gear damage. Once implemented into WT CMSs, this algorithm can automate data interpretation reducing the quantity of information that WT operators must handle.« less

  18. Reliability of externally fixed dynamometry hamstring strength testing in elite youth football players.

    PubMed

    Wollin, Martin; Purdam, Craig; Drew, Michael K

    2016-01-01

    To investigate inter and intra-tester reliability of an externally fixed dynamometry unilateral hamstring strength test, in the elite sports setting. Reliability study. Sixteen, injury-free, elite male youth football players (age=16.81±0.54 years, height=180.22±5.29cm, weight 73.88±6.54kg, BMI=22.57±1.42) gave written informed consent. Unilateral maximum isometric peak hamstring force was evaluated by externally fixed dynamometry for inter-tester, intra-day and intra-tester, inter-week reliability. The test position was standardised to correlate with the terminal swing phase of the gait running cycle. Inter and intra-tester values demonstrated good to high levels of reliability. The intra-class coefficient (ICC) for inter-tester, intra-day reliability was 0.87 (95% CI=0.75-0.93) with standard error of measure percentage (SEM%) 4.7 and minimal detectable change percentage (MDC%) 12.9. Intra-tester, inter-week reliability results were ICC 0.86 (95% CI, 0.74-0.93), SEM% 5.0 and MDC% 14.0. This study demonstrates good to high inter and intra-tester reliability of isometric externally fixed dynamometry unilateral hamstring strength testing in the regular elite sport setting involving elite male youth football players. The intra-class coefficient in association with the low standard error of measure and minimal detectable change percentages suggest that this procedure is appropriate for clinical and academic use as well as monitoring hamstring strength in the elite sport setting. Crown Copyright © 2015. Published by Elsevier Ltd. All rights reserved.

  19. Reliability, validity, and minimal detectable change of the push-off test scores in assessing upper extremity weight-bearing ability.

    PubMed

    Mehta, Saurabh P; George, Hannah R; Goering, Christian A; Shafer, Danielle R; Koester, Alan; Novotny, Steven

    2017-11-01

    Clinical measurement study. The push-off test (POT) was recently conceived and found to be reliable and valid for assessing weight bearing through injured wrist or elbow. However, further research with larger sample can lend credence to the preliminary findings supporting the use of the POT. This study examined the interrater reliability, construct validity, and measurement error for the POT in patients with wrist conditions. Participants with musculoskeletal (MSK) wrist conditions were recruited. The performance on the POT, grip isometric strength of wrist extensors was assessed. The shortened version of the Disabilities of the Arm, Shoulder and Hand and numeric pain rating scale were completed. The intraclass correlation coefficient assessed interrater reliability of the POT. Pearson correlation coefficients (r) examined the concurrent relationships between the POT and other measures. The standard error of measurement and the minimal detectable change at 90% confidence interval were assessed as measurement error and index of true change for the POT. A total of 50 participants with different elbow or wrist conditions (age: 48.1 ± 16.6 years) were included in this study. The results of this study strongly supported the interrater reliability (intraclass correlation coefficient: 0.96 and 0.93 for the affected and unaffected sides, respectively) of the POT in patients with wrist MSK conditions. The POT showed convergent relationships with the grip strength on the injured side (r = 0.89) and the wrist extensor strength (r = 0.7). The POT showed smaller standard error of measurement (1.9 kg). The minimal detectable change at 90% confidence interval for the POT was 4.4 kg for the sample. This study provides additional evidence to support the reliability and validity of the POT. This is the first study that provides the values for the measurement error and true change on the POT scores in patients with wrist MSK conditions. Further research should examine the responsiveness and discriminant validity of the POT in patients with wrist conditions. Copyright © 2017 Hanley & Belfus. Published by Elsevier Inc. All rights reserved.

  20. Reliability and minimal detectable change of physical performance measures in individuals with pre-manifest and manifest Huntington disease.

    PubMed

    Quinn, Lori; Khalil, Hanan; Dawes, Helen; Fritz, Nora E; Kegelmeyer, Deb; Kloos, Anne D; Gillard, Jonathan W; Busse, Monica

    2013-07-01

    Clinical intervention trials in people with Huntington disease (HD) have been limited by a lack of reliable and appropriate outcome measures. The purpose of this study was to determine the reliability and minimal detectable change (MDC) of various outcome measures that are potentially suitable for evaluating physical functioning in individuals with HD. This was a multicenter, prospective, observational study. Participants with pre-manifest and manifest HD (early, middle, and late stages) were recruited from 8 international sites to complete a battery of physical performance and functional measures at 2 assessments, separated by 1 week. Test-retest reliability (using intraclass correlation coefficients) and MDC values were calculated for all measures. Seventy-five individuals with HD (mean age=52.12 years, SD=11.82) participated in the study. Test-retest reliability was very high (>.90) for participants with manifest HD for the Six-Minute Walk Test (6MWT), 10-Meter Walk Test, Timed "Up & Go" Test (TUG), Berg Balance Scale (BBS), Physical Performance Test (PPT), Barthel Index, Rivermead Mobility Index, and Tinetti Mobility Test (TMT). Many MDC values suggested a relatively high degree of inherent variability, particularly in the middle stage of HD. Minimum detectable change values for participants with manifest HD that were relatively low across disease stages were found for the BBS (5), PPT (5), and TUG (2.98). For individuals with pre-manifest HD (n=11), the 6MWT and Four Square Step Test had high reliability and low MDC values. The sample size for the pre-manifest HD group was small. The BBS, PPT, and TUG appear most appropriate for clinical trials aimed at improving physical functioning in people with manifest HD. Further research in people with pre-manifest HD is necessary.

  1. Advanced Augmented White Cane with obstacle height and distance feedback.

    PubMed

    Pyun, Rosali; Kim, Yeongmi; Wespe, Pascal; Gassert, Roger; Schneller, Stefan

    2013-06-01

    The white cane is a widely used mobility aid that helps visually impaired people navigate the surroundings. While it reliably and intuitively extends the detection range of ground-level obstacles and drop-offs to about 1.2 m, it lacks the ability to detect trunk and head-level obstacles. Electronic Travel Aids (ETAs) have been proposed to overcome these limitations, but have found minimal adoption due to limitations such as low information content and low reliability thereof. Although existing ETAs extend the sensing range beyond that of the conventional white cane, most of them do not detect head-level obstacles and drop-offs, nor can they identify the vertical extent of obstacles. Furthermore, some ETAs work independent of the white cane, and thus reliable detection of surface textures and drop-offs is not provided. This paper introduces a novel ETA, the Advanced Augmented White Cane, which detects obstacles at four vertical levels and provides multi-sensory feedback. We evaluated the device in five blindfolded subjects through reaction time measurements following the detection of an obstacle, as well as through the reliability of dropoff detection. The results showed that our aid could help the user successfully detect an obstacle and identify its height, with an average reaction time of 410 msec. Drop-offs were reliably detected with an intraclass correlation > 0.95. This work is a first step towards a low-cost ETA to complement the functionality of the conventional white cane.

  2. Test-retest reliability and minimal detectable change of the Beck Depression Inventory and the Taiwan Geriatric Depression Scale in patients with Parkinson's disease

    PubMed Central

    Huang, Sheau-Ling; Hsieh, Ching-Lin; Wu, Ruey-Meei

    2017-01-01

    Background The Beck Depression Inventory II (BDI-II) and the Taiwan Geriatric Depression Scale (TGDS) are self-report scales used for assessing depression in patients with Parkinson’s disease (PD) and geriatric people. The minimal detectable change (MDC) represents the least amount of change that indicates real difference (i.e., beyond random measurement error) for a single subject. Our aim was to investigate the test-retest reliability and MDC of the BDI-II and the TGDS in people with PD. Methods Seventy patients were recruited from special clinics for movement disorders at a medical center. The patients’ mean age was 67.7 years, and 63.0% of the patients were male. All patients were assessed with the BDI-II and the TGDS twice, 2 weeks apart. We used the intraclass correlation coefficient (ICC) to determine the reliability between test and retest. We calculated the MDC based on standard error of measurement. The MDC% was calculated (i.e., by dividing the MDC by the possible maximal score of the measure). Results The test-retest reliabilities of the BDI-II/TGDS were high (ICC = 0.86/0.89). The MDCs (MDC%s) of the BDI-II and TGDS were 8.7 (13.8%) and 5.4 points (18.0%), respectively. Both measures had acceptable to nearly excellent random measurement errors. Conclusions The test-retest reliabilities of the BDI-II and the TGDS are high. The MDCs of both measures are acceptable to nearly excellent in people with PD. These findings imply that the BDI-II and the TGDS are suitable for use in a research context and in clinical settings to detect real change in a single subject. PMID:28945776

  3. Test-retest reliability and minimal detectable change scores for the timed "up & go" test, the six-minute walk test, and gait speed in people with Alzheimer disease.

    PubMed

    Ries, Julie D; Echternach, John L; Nof, Leah; Gagnon Blodgett, Michelle

    2009-06-01

    With the increasing incidence of Alzheimer disease (AD), determining the validity and reliability of outcome measures for people with this disease is necessary. The goals of this study were to assess test-retest reliability of data for the Timed "Up & Go" Test (TUG), the Six-Minute Walk Test (6MWT), and gait speed and to calculate minimal detectable change (MDC) scores for each outcome measure. Performance differences between groups with mild to moderate AD and moderately severe to severe AD (as determined by the Functional Assessment Staging [FAST] scale) were studied. This was a prospective, nonexperimental, descriptive methodological study. Background data collected for 51 people with AD included: use of an assistive device, Mini-Mental Status Examination scores, and FAST scale scores. Each participant engaged in 2 test sessions, separated by a 30- to 60-minute rest period, which included 2 TUG trials, 1 6MWT trial, and 2 gait speed trials using a computerized gait assessment system. A specific cuing protocol was followed to achieve optimal performance during test sessions. Test-retest reliability values for the TUG, the 6MWT, and gait speed were high for all participants together and for the mild to moderate AD and moderately severe to severe AD groups separately (intraclass correlation coefficients > or = .973); however, individual variability of performance also was high. Calculated MDC scores at the 90% confidence interval were: TUG=4.09 seconds, 6MWT=33.5 m (110 ft), and gait speed=9.4 cm/s. The 2 groups were significantly different in performance of clinical tests, with the participants who were more cognitively impaired being more physically and functionally impaired. A single researcher for data collection limited sample numbers and prohibited blinding to dementia level. The TUG, the 6MWT, and gait speed are reliable outcome measures for use with people with AD, recognizing that individual variability of performance is high. Minimal detectable change scores at the 90% confidence interval can be used to assess change in performance over time and the impact of treatment.

  4. The test-retest reliability and minimal detectable change of spatial and temporal gait variability during usual over-ground walking for younger and older adults.

    PubMed

    Almarwani, Maha; Perera, Subashan; VanSwearingen, Jessie M; Sparto, Patrick J; Brach, Jennifer S

    2016-02-01

    Gait variability is a marker of gait performance and future mobility status in older adults. Reliability of gait variability has been examined mainly in community dwelling older adults who are likely to fluctuate over time. The purpose of this study was to compare test-retest reliability and determine minimal detectable change (MDC) of spatial and temporal gait variability in younger and older adults. Forty younger (mean age=26.6 ± 6.0 years) and 46 older adults (mean age=78.1 ± 6.2 years) were included in the study. Gait characteristics were measured twice, approximately 1 week apart, using a computerized walkway (GaitMat II). Participants completed 4 passes on the GaitMat II at their self-selected walking speed. Test-retest reliability was calculated using Intra-class correlation coefficients (ICCs(2,1)), 95% limits of agreement (95% LoA) in conjunction with Bland-Altman plots, relative limits of agreement (LoA%) and standard error of measurement (SEM). The MDC at 90% and 95% level were also calculated. ICCs of gait variability ranged 0.26-0.65 in younger and 0.28-0.74 in older adults. The LoA% and SEM were consistently higher (i.e. less reliable) for all gait variables in older compared to younger adults except SEM for step width. The MDC was consistently larger for all gait variables in older compared to younger adults except step width. ICCs were of limited utility due to restricted ranges in younger adults. Based on absolute reliability measures and MDC, younger had greater test-retest reliability and smaller MDC of spatial and temporal gait variability compared to older adults. Copyright © 2015 Elsevier B.V. All rights reserved.

  5. Reliability, construct validity, and responsiveness of the neck disability index, patient-specific functional scale, and numeric pain rating scale in patients with cervical radiculopathy.

    PubMed

    Young, Ian A; Cleland, Joshua A; Michener, Lori A; Brown, Chris

    2010-10-01

    To examine the psychometric properties of the Neck Disability Index, Patient-Specific Functional Scale, and the Numeric Pain Rating Scale in a cohort of patients with cervical radiculopathy. A single-group repeated-measures design. Patients (n = 165) presenting to physical therapy with cervical radiculopathy completed the Neck Disability Index, Patient-Specific Functional Scale, and Numeric Pain Rating Scale at the baseline examination and at a follow-up. At the time of follow-up, all patients also completed the Global Rating of Change, which was used to dichotomize patients as improved or stable. Baseline and follow-up scores were used to determine the test-retest reliability, construct validity, and minimal levels of detectable and clinically important change for the Neck Disability Index, Patient-Specific Functional Scale, and Numeric Pain Rating Scale. Both the Neck Disability Index and Numeric Pain Rating Scale exhibited fair test-retest reliability, whereas the Patient-Specific Functional Scale exhibited poor reliability in patients with cervical radiculopathy. All three outcome measures showed adequate responsiveness in this patient population. The minimal detectable change was 13.4 for the Neck Disability Index, 3.3 for the Patient-Specific Functional Scale, and 4.1 for the Numeric Pain Rating Scale. The threshold for the minimal clinically important difference was 8.5 for the Neck Disability Index and 2.2 for both the Patient-Specific Functional Scale and Numeric Pain Rating Scale. In light of the varied distribution of symptoms in patients with cervical radiculopathy, future studies should investigate the psychometric properties of other neck-related disability measures in this patient population.

  6. IDENTIFICATION AND INTERPRETATION OF DEVELOPMENTAL NEUROTOXICITY EFFECTS: A REPORT FROM THE ILSI RESEARCH FOUNDATION/RISK SCIENCE INSTITUTE EXPERT WORKING GROUP ON NEURODEVELOPMENTAL ENDPOINTS

    EPA Science Inventory

    The reliable detection, measurement, and interpretation of treatment-related developmental neurotoxicity (DNT) effects depend on appropriate study design and execution, using scientifically established methodologies, with appropriate controls to minimize confounding factors. App...

  7. Strategy for continuous improvement in IC manufacturability, yield, and reliability

    NASA Astrophysics Data System (ADS)

    Dreier, Dean J.; Berry, Mark; Schani, Phil; Phillips, Michael; Steinberg, Joe; DePinto, Gary

    1993-01-01

    Continual improvements in yield, reliability and manufacturability measure a fab and ultimately result in Total Customer Satisfaction. A new organizational and technical methodology for continuous defect reduction has been established in a formal feedback loop, which relies on yield and reliability, failed bit map analysis, analytical tools, inline monitoring, cross functional teams and a defect engineering group. The strategy requires the fastest detection, identification and implementation of possible corrective actions. Feedback cycle time is minimized at all points to improve yield and reliability and reduce costs, essential for competitiveness in the memory business. Payoff was a 9.4X reduction in defectivity and a 6.2X improvement in reliability of 256 K fast SRAMs over 20 months.

  8. Test-retest reliability of lower limb isokinetic endurance in COPD: A comparison of angular velocities

    PubMed Central

    Ribeiro, Fernanda; Lépine, Pierre-Alexis; Garceau-Bolduc, Corine; Coats, Valérie; Allard, Étienne; Maltais, François; Saey, Didier

    2015-01-01

    Background The purpose of this study was to determine and compare the test-retest reliability of quadriceps isokinetic endurance testing at two knee angular velocities in patients with chronic obstructive pulmonary disease (COPD). Methods After one familiarization session, 14 patients with moderate to severe COPD (mean age 65±4 years; forced expiratory volume in 1 second (FEV1) 55%±18% predicted) performed two quadriceps isokinetic endurance tests on two separate occasions within a 5–7-day interval. Quadriceps isokinetic endurance tests consisted of 30 maximal knee extensions at angular velocities of 90° and 180° per second, performed in random order. Test-retest reliability was assessed for peak torque, muscle endurance, work slope, work fatigue index, and changes in FEV1 for dyspnea and leg fatigue from rest to the end of the test. The intraclass correlation coefficient, minimal detectable change, and limits of agreement were calculated. Results High test-retest reliability was identified for peak torque and muscle total work at both velocities. Work fatigue index was considered reliable at 90° per second but not at 180° per second. A lower reliability was identified for dyspnea and leg fatigue scores at both angular velocities. Conclusion Despite a limited sample size, our findings support the use of a 30-maximal repetition isokinetic muscle testing procedure at angular velocities of 90° and 180° per second in patients with moderate to severe COPD. Endurance measurement (total isokinetic work) at 90° per second was highly reliable, with a minimal detectable change at the 95% confidence level of 10%. Peak torque and fatigue index could also be assessed reliably at 90° per second. Evaluation of dyspnea and leg fatigue using the modified Borg scale of perceived exertion was poorly reliable and its clinical usefulness is questionable. These results should be useful in the design and interpretation of future interventions aimed at improving muscle endurance in COPD. PMID:26124656

  9. Intratester Reliability and Construct Validity of a Hip Abductor Eccentric Strength Test.

    PubMed

    Brindle, Richard A; Ebaugh, David; Milner, Clare E

    2018-06-06

    Side-lying hip abductor strength tests are commonly used to evaluate muscle strength. In a "break" test, the tester applies sufficient force to lower the limb to the table while the patient resists. The peak force is postulated to occur while the leg is lowering, thus representing the participant's eccentric muscle strength. However, it is unclear whether peak force occurs before or after the leg begins to lower. To determine intrarater reliability and construct validity of a hip abductor eccentric strength test. Intrarater reliability and construct validity study. Twenty healthy adults (26 [6] y; 1.66 [0.06] m; 62.2 [8.0] kg) made 2 visits to the laboratory at least 1 week apart. During the hip abductor eccentric strength test, a handheld dynamometer recorded peak force and time to peak force, and limb position was recorded via a motion capture system. Intrarater reliability was determined using intraclass correlation, SEM, and minimal detectable difference. Construct validity was assessed by determining if peak force occurred after the start of the lowering phase using a 1-sample t test. The hip abductor eccentric strength test had substantial intrarater reliability (intraclass correlation (3,3)  = .88; 95% confidence interval, .65-.95), SEM of 0.9 %BWh, and a minimal detectable difference of 2.5 %BWh. Construct validity was established as peak force occurred 2.1 (0.6) seconds (range: 0.7-3.7 s) after the start of the lowering phase of the test (P ≤ .001). The hip abductor eccentric strength test is a valid and reliable measure of eccentric muscle strength. This test may be used clinically to assess changes in eccentric muscle strength over time.

  10. Psychometric Properties of the Quantitative Myasthenia Gravis Score and the Myasthenia Gravis Composite Scale.

    PubMed

    Barnett, Carolina; Merkies, Ingemar S J; Katzberg, Hans; Bril, Vera

    2015-09-02

    The Quantitative Myasthenia Gravis Score and the Myasthenia Gravis Composite are two commonly used outcome measures in Myasthenia Gravis. So far, their measurement properties have not been compared, so we aimed to study their psychometric properties using the Rasch model. 251 patients with stable myasthenia gravis were assessed with both scales, and 211 patients returned for a second assessment. We studied fit to the Rasch model at the first visit, and compared item fit, thresholds, differential item functioning, local dependence, person separation index, and tests for unidimensionality. We also assessed test-retest reliability and estimated the Minimal Detectable Change. Neither scale fit the Rasch model (X2p <  0.05). The Myasthenia Gravis Composite had lower discrimination properties than the Quantitative Myasthenia Gravis Scale (Person Separation Index: 0.14 and 0.7). There was local dependence in both scales, as well as differential item functioning for ocular and generalized disease. Disordered thresholds were found in 6(60%) items of the Myasthenia Gravis Composite and in 4(31%) of the Quantitative Myasthenia Gravis Score. Both tools had adequate test-retest reliability (ICCs >0.8). The minimally detectable change was 4.9 points for the Myasthenia Gravis Composite and 4.3 points for the Quantitative Myasthenia Gravis Score. Neither scale fulfilled Rasch model expectations. The Quantitative Myasthenia Gravis Score has higher discrimination than the Myasthenia Gravis Composite. Both tools have items with disordered thresholds, differential item functioning and local dependency. There was evidence of multidimensionality in the QMGS. The minimal detectable change values are higher than previous studies on the minimal significant change. These findings might inform future modifications of these tools.

  11. Reliable sagittal plane kinematic gait assessments are feasible using low-cost webcam technology.

    PubMed

    Saner, Robert J; Washabaugh, Edward P; Krishnan, Chandramouli

    2017-07-01

    Three-dimensional (3-D) motion capture systems are commonly used for gait analysis because they provide reliable and accurate measurements. However, the downside of this approach is that it is expensive and requires technical expertise; thus making it less feasible in the clinic. To address this limitation, we recently developed and validated (using a high-precision walking robot) a low-cost, two-dimensional (2-D) real-time motion tracking approach using a simple webcam and LabVIEW Vision Assistant. The purpose of this study was to establish the repeatability and minimal detectable change values of hip and knee sagittal plane gait kinematics recorded using this system. Twenty-one healthy subjects underwent two kinematic assessments while walking on a treadmill at a range of gait velocities. Intraclass correlation coefficients (ICC) and minimal detectable change (MDC) values were calculated for commonly used hip and knee kinematic parameters to demonstrate the reliability of the system. Additionally, Bland-Altman plots were generated to examine the agreement between the measurements recorded on two different days. The system demonstrated good to excellent reliability (ICC>0.75) for all the gait parameters tested on this study. The MDC values were typically low (<5°) for most of the parameters. The Bland-Altman plots indicated that there was no systematic error or bias in kinematic measurements and showed good agreement between measurements obtained on two different days. These results indicate that kinematic gait assessments using webcam technology can be reliably used for clinical and research purposes. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. Comparison of the functional rating index and the 18-item Roland-Morris Disability Questionnaire: responsiveness and reliability.

    PubMed

    Chansirinukor, Wunpen; Maher, Christopher G; Latimer, Jane; Hush, Julia

    2005-01-01

    Retrospective design. To compare the responsiveness and test-retest reliability of the Functional Rating Index and the 18-item version of the Roland-Morris Disability Questionnaire in detecting change in disability in patients with work-related low back pain. Many low back pain-specific disability questionnaires are available, including the Functional Rating Index and the 18-item version of the Roland-Morris Disability Questionnaire. No previous study has compared the responsiveness and reliability of these questionnaires. Files of patients who had been treated for work-related low back pain at a physical therapy clinic were reviewed, and those containing initial and follow-up Functional Rating Index and 18-item Roland-Morris Disability Questionnaires were selected. The responsiveness of both questionnaires was compared using two different methods. First, using the assumption that patients receiving treatment improve over time, various responsiveness coefficients were calculated. Second, using change in work status as an external criterion to identify improved and nonimproved patients, Spearman's rho and receiver operating characteristic curves were calculated. Reliability was estimated from the subset of patients who reported no change in their condition over this period and expressed with the intraclass correlation coefficient and the minimal detectable change. One hundred and forty-three patient files were retrieved. The responsiveness coefficients for the Functional Rating Index were greater than for the 18-item Roland-Morris Disability Questionnaire. The intraclass correlation coefficient values for both questionnaires calculated from 96 patient files were similar, but the minimal detectable change for the Functional Rating Index was less than for the 18-item Roland-Morris Disability Questionnaire. The Functional Rating Index seems preferable to the 18-item Roland-Morris Disability Questionnaire for use in clinical trials and clinical practice.

  13. Principles of Statistics: What the Sports Medicine Professional Needs to Know.

    PubMed

    Riemann, Bryan L; Lininger, Monica R

    2018-07-01

    Understanding the results and statistics reported in original research remains a large challenge for many sports medicine practitioners and, in turn, may be among one of the biggest barriers to integrating research into sports medicine practice. The purpose of this article is to provide minimal essentials a sports medicine practitioner needs to know about interpreting statistics and research results to facilitate the incorporation of the latest evidence into practice. Topics covered include the difference between statistical significance and clinical meaningfulness; effect sizes and confidence intervals; reliability statistics, including the minimal detectable difference and minimal important difference; and statistical power. Copyright © 2018 Elsevier Inc. All rights reserved.

  14. Data Verification Tools for Minimizing Management Costs of Dense Air-Quality Monitoring Networks.

    PubMed

    Miskell, Georgia; Salmond, Jennifer; Alavi-Shoshtari, Maryam; Bart, Mark; Ainslie, Bruce; Grange, Stuart; McKendry, Ian G; Henshaw, Geoff S; Williams, David E

    2016-01-19

    Aiming at minimizing the costs, both of capital expenditure and maintenance, of an extensive air-quality measurement network, we present simple statistical methods that do not require extensive training data sets for automated real-time verification of the reliability of data delivered by a spatially dense hybrid network of both low-cost and reference ozone measurement instruments. Ozone is a pollutant that has a relatively smooth spatial spread over a large scale although there can be significant small-scale variations. We take advantage of these characteristics and demonstrate detection of instrument calibration drift within a few days using a rolling 72 h comparison of hourly averaged data from the test instrument with that from suitably defined proxies. We define the required characteristics of the proxy measurements by working from a definition of the network purpose and specification, in this case reliable determination of the proportion of hourly averaged ozone measurements that are above a threshold in any given day, and detection of calibration drift of greater than ±30% in slope or ±5 parts-per-billion in offset. By analyzing results of a study of an extensive deployment of low-cost instruments in the Lower Fraser Valley, we demonstrate that proxies can be established using land-use criteria and that simple statistical comparisons can identify low-cost instruments that are not stable and therefore need replacing. We propose that a minimal set of compliant reference instruments can be used to verify the reliability of data from a much more extensive network of low-cost devices.

  15. Self-Tuning Method for Increased Obstacle Detection Reliability Based on Internet of Things LiDAR Sensor Models

    PubMed Central

    2018-01-01

    On-chip LiDAR sensors for vehicle collision avoidance are a rapidly expanding area of research and development. The assessment of reliable obstacle detection using data collected by LiDAR sensors has become a key issue that the scientific community is actively exploring. The design of a self-tuning methodology and its implementation are presented in this paper, to maximize the reliability of LiDAR sensors network for obstacle detection in the ‘Internet of Things’ (IoT) mobility scenarios. The Webots Automobile 3D simulation tool for emulating sensor interaction in complex driving environments is selected in order to achieve that objective. Furthermore, a model-based framework is defined that employs a point-cloud clustering technique, and an error-based prediction model library that is composed of a multilayer perceptron neural network, and k-nearest neighbors and linear regression models. Finally, a reinforcement learning technique, specifically a Q-learning method, is implemented to determine the number of LiDAR sensors that are required to increase sensor reliability for obstacle localization tasks. In addition, a IoT driving assistance user scenario, connecting a five LiDAR sensor network is designed and implemented to validate the accuracy of the computational intelligence-based framework. The results demonstrated that the self-tuning method is an appropriate strategy to increase the reliability of the sensor network while minimizing detection thresholds. PMID:29748521

  16. Self-Tuning Method for Increased Obstacle Detection Reliability Based on Internet of Things LiDAR Sensor Models.

    PubMed

    Castaño, Fernando; Beruvides, Gerardo; Villalonga, Alberto; Haber, Rodolfo E

    2018-05-10

    On-chip LiDAR sensors for vehicle collision avoidance are a rapidly expanding area of research and development. The assessment of reliable obstacle detection using data collected by LiDAR sensors has become a key issue that the scientific community is actively exploring. The design of a self-tuning methodology and its implementation are presented in this paper, to maximize the reliability of LiDAR sensors network for obstacle detection in the 'Internet of Things' (IoT) mobility scenarios. The Webots Automobile 3D simulation tool for emulating sensor interaction in complex driving environments is selected in order to achieve that objective. Furthermore, a model-based framework is defined that employs a point-cloud clustering technique, and an error-based prediction model library that is composed of a multilayer perceptron neural network, and k-nearest neighbors and linear regression models. Finally, a reinforcement learning technique, specifically a Q-learning method, is implemented to determine the number of LiDAR sensors that are required to increase sensor reliability for obstacle localization tasks. In addition, a IoT driving assistance user scenario, connecting a five LiDAR sensor network is designed and implemented to validate the accuracy of the computational intelligence-based framework. The results demonstrated that the self-tuning method is an appropriate strategy to increase the reliability of the sensor network while minimizing detection thresholds.

  17. Neck Flexor and Extensor Muscle Endurance in Subclinical Neck Pain: Intrarater Reliability, Standard Error of Measurement, Minimal Detectable Change, and Comparison With Asymptomatic Participants in a University Student Population.

    PubMed

    Lourenço, Ana S; Lameiras, Carina; Silva, Anabela G

    2016-01-01

    The aims of this study were to assess intrarater reliability and to calculate the standard error of measurement (SEM) and minimal detectable change (MDC) for deep neck flexor and neck extensor muscle endurance tests, and compare the results between individuals with and without subclinical neck pain. Participants were students of the University of Aveiro reporting subclinical neck pain and asymptomatic participants matched for sex and age to the neck pain group. Data on endurance capacity of the deep neck flexors and neck extensors were collected by a blinded assessor using the deep neck flexor endurance test and the extensor endurance test, respectively. Intraclass correlation coefficients (ICCs), SEM, and MDC were calculated for measurements taken within a session by the same assessor. Differences between groups for endurance capacity were investigated using a Mann-Whitney U test. The deep neck flexor endurance test (ICC = 0.71; SEM = 6.91 seconds; MDC = 19.15 seconds) and neck extensor endurance test (ICC = 0.73; SEM = 9.84 minutes; MDC = 2.34 minutes) are reliable. No significant differences were found between participants with and without neck pain for both tests of muscle endurance (P > .05). The endurance capacity of the deep neck flexors and neck extensors can be reliably measured in participants with subclinical neck pain. However, the wide SEM and MDC might limit the sensitivity of these tests. Copyright © 2016. Published by Elsevier Inc.

  18. Life-Space Assessment questionnaire: Novel measurement properties for Brazilian community-dwelling older adults.

    PubMed

    Simões, Maria do Socorro Mp; Garcia, Isabel Ff; Costa, Lucíola da Cm; Lunardi, Adriana C

    2018-05-01

    The Life-Space Assessment (LSA) assesses mobility from the spaces that older adults go, and how often and how independent they move. Despite its increased use, LSA measurement properties remain unclear. The aim of the present study was to analyze the content validity, reliability, construct validity and interpretability of the LSA for Brazilian community-dwelling older adults. In this clinimetric study we analyzed the measurement properties (content validity, reliability, construct validity and interpretability) of the LSA administered to 80 Brazilian community-dwelling older adults. Reliability was analyzed by Cronbach's alpha (internal consistency), intraclass correlation coefficients and 95% confidence interval (reproducibility), and standard error of measurement (measurement error). Construct validity was analyzed by Pearson's correlations between the LSA and accelerometry (time in inactivity and moderate-to-vigorous activities), and interpretability was analyzed by determination of the minimal detectable change, and floor and ceiling effects. The LSA met the criteria for content validity. The Cronbach's alpha was 0.92, intraclass correlation coefficient was 0.97 (95% confidence interval 0.95-0.98) and standard error of measurement was 4.12. The LSA showed convergence with accelerometry (negative correlation with time in inactivity and positive correlation with time in moderate to vigorous activities), the minimal detectable change was 0.36 and we observed no floor or ceiling effects. The LSA showed adequate reliability, validity and interpretability for life-space mobility assessment of Brazilian community-dwelling older adults. Geriatr Gerontol Int 2018; 18: 783-789. © 2018 Japan Geriatrics Society.

  19. Reliability of diabetic patients' gait parameters in a challenging environment.

    PubMed

    Allet, L; Armand, S; de Bie, R A; Golay, A; Monnin, D; Aminian, K; de Bruin, E D

    2008-11-01

    Activities of daily life require us to move about in challenging environments and to walk on varied surfaces. Irregular terrain has been shown to influence gait parameters, especially in a population at risk for falling. A precise portable measurement system would permit objective gait analysis under such conditions. The aims of this study are to (a) investigate the reliability of gait parameters measured with the Physilog in diabetic patients walking on different surfaces (tar, grass, and stones); (b) identify the measurement error (precision); (c) identify the minimal clinical detectable change. 16 patients with Type 2 diabetes were measured twice within 8 days. After clinical examination patients walked, equipped with a Physilog, on the three aforementioned surfaces. ICC for each surface was excellent for within-visit analyses (>0.938). Inter-visit ICC's (0.753) were excellent except for the knee range parameter (>0.503). The coefficient of variation (CV) was lower than 5% for most of the parameters. Bland and Altman Plots, SEM and SDC showed precise values, distributed around zero for all surfaces. Good reliability of Physilog measurements on different surfaces suggests that Physilog could facilitate the study of diabetic patients' gait in conditions close to real-life situations. Gait parameters during complex locomotor activities (e.g. stair-climbing, curbs, slopes) have not yet been extensively investigated. Good reliability, small measurement error and values of minimal clinical detectable change recommend the utilization of Physilog for the evaluation of gait parameters in diabetic patients.

  20. Requirements for diagnosis of malaria at different levels of the laboratory network in Africa.

    PubMed

    Long, Earl G

    2009-06-01

    The rapid increase of resistance to cheap, reliable antimalarials, the increasing cost of effective drugs, and the low specificity of clinical diagnosis has increased the need for more reliable diagnostic methods for malaria. The most commonly used and most reliable remains microscopic examination of stained blood smears, but this technique requires skilled personnel, precision instruments, and ideally a source of electricity. Microscopy has the advantage of enabling the examiner to identify the species, stage, and density of an infection. An alternative to microscopy is the rapid diagnostic test (RDT), which uses a labeled monoclonal antibody to detect circulating parasitic antigens. This test is most commonly used to detect Plasmodium falciparum infections and is available in a plastic cassette format. Both microscopy and RDTs should be available at all levels of laboratory service in endemic areas, but in peripheral laboratories with minimally trained staff, the RDT may be a more practical diagnostic method.

  1. From Data to Knowledge — Faster: GOES Early Fire Detection System to Inform Operational Wildfire Response and Management

    NASA Astrophysics Data System (ADS)

    Koltunov, A.; Quayle, B.; Prins, E. M.; Ambrosia, V. G.; Ustin, S.

    2014-12-01

    Fire managers at various levels require near-real-time, low-cost, systematic, and reliable early detection capabilities with minimal latency to effectively respond to wildfire ignitions and minimize the risk of catastrophic development. The GOES satellite images collected for vast territories at high temporal frequencies provide a consistent and reliable source for operational active fire mapping realized by the WF-ABBA algorithm. However, their potential to provide early warning or rapid confirmation of initial fire ignition reports from conventional sources remains underutilized, partly because the operational wildfire detection has been successfully optimized for users and applications for which timeliness of initial detection is a low priority, contrasting to the needs of first responders. We present our progress in developing the GOES Early Fire Detection (GOES-EFD) system, a collaborative effort led by University of California-Davis and USDA Forest Service. The GOES-EFD specifically focuses on first detection timeliness for wildfire incidents. It is automatically trained for a monitored scene and capitalizes on multiyear cross-disciplinary algorithm research. Initial retrospective tests in Western US demonstrate significantly earlier identification detection of new ignitions than existing operational capabilities and a further improvement prospect. The GOES-EFD-β prototype will be initially deployed for the Western US region to process imagery from GOES-NOP and the rapid and 4 times higher spatial resolution imagery from GOES-R — the upcoming next generation of GOES satellites. These and other enhanced capabilities of GOES-R are expected to significantly improve the timeliness of fire ignition information from GOES-EFD.

  2. Reliability and minimal detectable difference in multisegment foot kinematics during shod walking and running.

    PubMed

    Milner, Clare E; Brindle, Richard A

    2016-01-01

    There has been increased interest recently in measuring kinematics within the foot during gait. While several multisegment foot models have appeared in the literature, the Oxford foot model has been used frequently for both walking and running. Several studies have reported the reliability for the Oxford foot model, but most studies to date have reported reliability for barefoot walking. The purpose of this study was to determine between-day (intra-rater) and within-session (inter-trial) reliability of the modified Oxford foot model during shod walking and running and calculate minimum detectable difference for common variables of interest. Healthy adult male runners participated. Participants ran and walked in the gait laboratory for five trials of each. Three-dimensional gait analysis was conducted and foot and ankle joint angle time series data were calculated. Participants returned for a second gait analysis at least 5 days later. Intraclass correlation coefficients and minimum detectable difference were determined for walking and for running, to indicate both within-session and between-day reliability. Overall, relative variables were more reliable than absolute variables, and within-session reliability was greater than between-day reliability. Between-day intraclass correlation coefficients were comparable to those reported previously for adults walking barefoot. It is an extension in the use of the Oxford foot model to incorporate wearing a shoe while maintaining marker placement directly on the skin for each segment. These reliability data for walking and running will aid in the determination of meaningful differences in studies which use this model during shod gait. Copyright © 2015 Elsevier B.V. All rights reserved.

  3. Reliability and minimal detectable change of a modified passive neck flexion test in patients with chronic nonspecific neck pain and asymptomatic subjects.

    PubMed

    López-de-Uralde-Villanueva, Ibai; Acuyo-Osorio, Mario; Prieto-Aldana, María; La Touche, Roy

    2017-04-01

    The Passive Neck Flexion Test (PNFT) can diagnose meningitis and potential spinal disorders. Little evidence is available concerning the use of a modified version of the PNFT (mPNFT) in patients with chronic nonspecific neck pain (CNSNP). To assess the reliability of the mPNFT in subjects with and without CNSNP. The secondary objective was to assess the differences in the symptoms provoked by the mPNFT between these two populations. We used repeated measures concordance design for the main objective and cross-sectional design for the secondary objective. A total of 30 asymptomatic subjects and 34 patients with CNSNP were recruited. The following measures were recorded: the range of motion at the onset of symptoms (OS-mPNFT), the range of motion at the submaximal pain (SP-mPNFT), and evoked pain intensity on the mPNFT (VAS-mPNFT). Good to excellent reliability was observed for OS-mPNFT and SP-mPNFT in the asymptomatic group (intra-examiner reliability: 0.95-0.97; inter-examiner reliability: 0.86-0.90; intra-examiner test-retest reliability: 0.84-0.87). In the CNSNP group, a good to excellent reliability was obtained for the OS-mPNFT (intra-examiner reliability: 0.89-0.96; inter-examiner reliability: 0.83-0.86; intra-examiner test-retest reliability: 0.83-0.85) and the SP-PNFT (intra-examiner reliability: 0.94-0.98; inter-examiner reliability: 0.80-0.82; intra-examiner test-retest reliability: 0.88-0.91). The CNSNP group showed statistically significant differences in OS-mPNFT (t = 4.92; P < 0.001), SP-mPNFT (t = 2.79; P = 0.007) and in VAS-mPNFT (t = -10.39; P < 0.001) versus the asymptomatic group. The mPNFT is a reliable tool regardless of the examiner and the time factor. Patients with CNSNP have a decrease range of motion and more pain than asymptomatic subjects in the mPNFT. This exceeds the minimal detectable changes for OS-mPNFT and VAS-mPNFT. Copyright © 2017 Elsevier Ltd. All rights reserved.

  4. Integrated material state awareness system with self-learning symbiotic diagnostic algorithms and models

    NASA Astrophysics Data System (ADS)

    Banerjee, Sourav; Liu, Lie; Liu, S. T.; Yuan, Fuh-Gwo; Beard, Shawn

    2011-04-01

    Materials State Awareness (MSA) goes beyond traditional NDE and SHM in its challenge to characterize the current state of material damage before the onset of macro-damage such as cracks. A highly reliable, minimally invasive system for MSA of Aerospace Structures, Naval structures as well as next generation space systems is critically needed. Development of such a system will require a reliable SHM system that can detect the onset of damage well before the flaw grows to a critical size. Therefore, it is important to develop an integrated SHM system that not only detects macroscale damages in the structures but also provides an early indication of flaw precursors and microdamages. The early warning for flaw precursors and their evolution provided by an SHM system can then be used to define remedial strategies before the structural damage leads to failure, and significantly improve the safety and reliability of the structures. Thus, in this article a preliminary concept of developing the Hybrid Distributed Sensor Network Integrated with Self-learning Symbiotic Diagnostic Algorithms and Models to accurately and reliably detect the precursors to damages that occur to the structure are discussed. Experiments conducted in a laboratory environment shows potential of the proposed technique.

  5. A novel device using the Nordic hamstring exercise to assess eccentric knee flexor strength: a reliability and retrospective injury study.

    PubMed

    Opar, David A; Piatkowski, Timothy; Williams, Morgan D; Shield, Anthony J

    2013-09-01

    Reliability and case-control injury study. To determine if a novel device designed to measure eccentric knee flexor strength via the Nordic hamstring exercise displays acceptable test-retest reliability; to determine normative values for eccentric knee flexor strength derived from the device in individuals without a history of hamstring strain injury (HSI); and to determine if the device can detect weakness in elite athletes with a previous history of unilateral HSI. HSI and reinjury are the most common cause of lost playing time in a number of sports. Eccentric knee flexor weakness is a major modifiable risk factor for future HSI. However, at present, there is a lack of easily accessible equipment to assess eccentric knee flexor strength. Thirty recreationally active males without a history of HSI completed the Nordic hamstring exercise on the device on 2 separate occasions. Intraclass correlation coefficients, typical error, typical error as a coefficient of variation, and minimal detectable change at a 95% confidence level were calculated. Normative strength data were determined using the most reliable measurement. An additional 20 elite athletes with a unilateral history of HSI within the previous 12 months performed the Nordic hamstring exercise on the device to determine if residual eccentric muscle weakness existed in the previously injured limb. The device displayed high to moderate reliability (intraclass correlation coefficient = 0.83-0.90; typical error, 21.7-27.5 N; typical error as a coefficient of variation, 5.8%-8.5%; minimal detectable change at a 95% confidence level, 60.1-76.2 N). Mean ± SD normative eccentric flexor strength in the uninjured group was 344.7 ± 61.1 N for the left and 361.2 ± 65.1 N for the right side. The previously injured limb was 15% weaker than the contralateral uninjured limb (mean difference, 50.3 N; 95% confidence interval: 25.7, 74.9; P<.01), 15% weaker than the normative left limb (mean difference, 50.0 N; 95% confidence interval: 1.4, 98.5; P = .04), and 18% weaker than the normative right limb (mean difference, 66.5 N; 95% confidence interval: 18.0, 115.1; P<.01). The experimental device offers a reliable method to measure eccentric knee flexor strength and strength asymmetry and to detect residual weakness in previously injured elite athletes.

  6. Test-Retest Reliability and Minimal Detectable Change of the D2 Test of Attention in Patients with Schizophrenia.

    PubMed

    Lee, Posen; Lu, Wen-Shian; Liu, Chin-Hsuan; Lin, Hung-Yu; Hsieh, Ching-Lin

    2017-12-08

    The d2 Test of Attention (D2) is a commonly used measure of selective attention for patients with schizophrenia. However, its test-retest reliability and minimal detectable change (MDC) are unknown in patients with schizophrenia, limiting its utility in both clinical and research settings. The aim of the present study was to examine the test-retest reliability and MDC of the D2 in patients with schizophrenia. A rater administered the D2 on 108 patients with schizophrenia twice at a 1-month interval. Test-retest reliability was determined through the calculation of the intra-class correlation coefficient (ICC). We also carried out Bland-Altman analysis, which included a scatter plot of the differences between test and retest against their mean. Systematic biases were evaluated by use of a paired t-test. The ICCs for the D2 ranged from 0.78 to 0.94. The MDCs (MDC%) of the seven subscores were 102.3 (29.7), 19.4 (85.0), 7.2 (94.6), 21.0 (69.0), 104.0 (33.1), 105.0 (35.8), and 7.8 (47.8), which represented limited-to-acceptable random measurement error. Trends in the Bland-Altman plots of the omissions (E1), commissions (E2), and errors (E) were noted, presenting that the data had heteroscedasticity. According to the results, the D2 had good test-retest reliability, especially in the scores of TN, TN-E, and CP. For the further research, finding a way to improve the administration procedure to reduce random measurement error would be important for the E1, E2, E, and FR subscores. © The Author(s) 2017. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  7. Test-retest reliability of posture measurements in adolescents with idiopathic scoliosis.

    PubMed

    Heitz, Pierre-Henri; Aubin-Fournier, Jean-François; Parent, Éric; Fortin, Carole

    2018-05-07

    Posture changes are a major consequence of IS (IS). Posture changes can lead to psychosocial and physical impairments in adolescents with IS. Therefore, it is important to assess posture but the test-retest reliability of posture measurements still remains unknown in this population. The primary objective was to determine the test-retest reliability of 25 head and trunk posture indices using the Clinical Photographic Postural Assessment Tool (CPPAT) in adolescents with IS. The secondary objective was to determine the standard error of measurement and the minimal detectable change. This is a prospective test-retest reliability study carried out at two tertiary university hospital centers. Forty-one adolescents with IS, aged 10 to 16 years old with curves 10 to 45 o and treated non-operatively were recruited. Two posture assessments were done using the CPPAT five to 10 days apart following a standardized procedure. Photographs were analyzed with the CPPAT software by digitizing reference landmarks placed on the participant by a physiotherapist evaluator. Generalizability theory was used to obtain a coefficient of dependability, standard error of measurement and the minimal detectable change at the 90% confidence interval. This project was supported by the Canadian Pediatric Spine Society (CPSS: 10000$). There is no study-specific conflicts of interest-associated biases. Fourteen of 25 posture indices had a good reliability (ϕ ≥ 0.78), ten of 25 had moderate reliability (ϕ = 0.55 to 0.74) and one had poor reliability (ϕ = 0.45). The most reliable posture indices were waist angles asymmetry (ϕ = 0.93), right waist angle (ϕ = 0.91) and frontal trunk list (ϕ = 0.92). Right sagittal trunk list was the least reliable posture index (ϕ = 0.45). The MDC 90 values ranged from 2.6 to 10.3° for angular measurements and from 8.4 to 35.1 mm for linear measurements. This study demonstrates that most posture indices, especially the trunk posture indices, are reproducible in time among adolescents with IS and provides reference values. Clinicians and researchers can use these reference values in order to assess change in posture over time attributable to treatment effectiveness. Copyright © 2018. Published by Elsevier Inc.

  8. Exhaust Air Dust Monitoring is Superior to Soiled Bedding Sentinels for the Detection of Pasteurella pneumotropica in Individually Ventilated Cage Systems.

    PubMed

    Miller, Manuel; Ritter, Brbel; Zorn, Julia; Brielmeier, Markus

    2016-11-01

    Reliable detection of unwanted organisms is essential for meaningful health monitoring in experimental animal facilities. Currently, most rodents are housed in IVC systems, which prevent the aerogenic transmission of pathogens between cages. Typically soiled-bedding sentinels (SBS) exposed to soiled bedding collected from a population of animals within an IVC rack are tested as representatives, but infectious agents often go undetected due to inefficient transmission. Pasteurellaceae are among the most prevalent bacterial pathogens isolated from experimental mice, and the failure of SBS to detect these bacteria is well established. In this study, we investigated whether analysis of exhaust air dust (EAD) samples by using a sensitive and specific real-time PCR assay is superior to conventional SBS monitoring for the detection of Pasteurella pneumotropica (Pp) infections. In a rack with a known prevalence of Pp-positive mice, weekly EAD sampling was compared with the classic SBS method over 3 mo. In 6 rounds of testing, with a prevalence of 5 infected mice in each of 7 cages in a rack of 63 cages, EAD PCR detected Pp at every weekly time point; SBS failed to detect Pp in all cases. The minimal prevalence of Pp-infected mice required to obtain a reliable positive result by EAD PCR testing was determined to be 1 in 63 cages. Reliable detection of Pp was achieved after only 1 wk of exposure. Analysis of EAD samples by real-time PCR assay provides a sensitive, simple, and reliable approach for Pp identification in laboratory mice.

  9. Exhaust Air Dust Monitoring is Superior to Soiled Bedding Sentinels for the Detection of Pasteurella pneumotropica in Individually Ventilated Cage Systems

    PubMed Central

    Miller, Manuel; Ritter, Bärbel; Zorn, Julia; Brielmeier, Markus

    2016-01-01

    Reliable detection of unwanted organisms is essential for meaningful health monitoring in experimental animal facilities. Currently, most rodents are housed in IVC systems, which prevent the aerogenic transmission of pathogens between cages. Typically soiled-bedding sentinels (SBS) exposed to soiled bedding collected from a population of animals within an IVC rack are tested as representatives, but infectious agents often go undetected due to inefficient transmission. Pasteurellaceae are among the most prevalent bacterial pathogens isolated from experimental mice, and the failure of SBS to detect these bacteria is well established. In this study, we investigated whether analysis of exhaust air dust (EAD) samples by using a sensitive and specific real-time PCR assay is superior to conventional SBS monitoring for the detection of Pasteurella pneumotropica (Pp) infections. In a rack with a known prevalence of Pp-positive mice, weekly EAD sampling was compared with the classic SBS method over 3 mo. In 6 rounds of testing, with a prevalence of 5 infected mice in each of 7 cages in a rack of 63 cages, EAD PCR detected Pp at every weekly time point; SBS failed to detect Pp in all cases. The minimal prevalence of Pp-infected mice required to obtain a reliable positive result by EAD PCR testing was determined to be 1 in 63 cages. Reliable detection of Pp was achieved after only 1 wk of exposure. Analysis of EAD samples by real-time PCR assay provides a sensitive, simple, and reliable approach for Pp identification in laboratory mice. PMID:27931316

  10. Reliable detection of fluence anomalies in EPID-based IMRT pretreatment quality assurance using pixel intensity deviations

    PubMed Central

    Gordon, J. J.; Gardner, J. K.; Wang, S.; Siebers, J. V.

    2012-01-01

    Purpose: This work uses repeat images of intensity modulated radiation therapy (IMRT) fields to quantify fluence anomalies (i.e., delivery errors) that can be reliably detected in electronic portal images used for IMRT pretreatment quality assurance. Methods: Repeat images of 11 clinical IMRT fields are acquired on a Varian Trilogy linear accelerator at energies of 6 MV and 18 MV. Acquired images are corrected for output variations and registered to minimize the impact of linear accelerator and electronic portal imaging device (EPID) positioning deviations. Detection studies are performed in which rectangular anomalies of various sizes are inserted into the images. The performance of detection strategies based on pixel intensity deviations (PIDs) and gamma indices is evaluated using receiver operating characteristic analysis. Results: Residual differences between registered images are due to interfraction positional deviations of jaws and multileaf collimator leaves, plus imager noise. Positional deviations produce large intensity differences that degrade anomaly detection. Gradient effects are suppressed in PIDs using gradient scaling. Background noise is suppressed using median filtering. In the majority of images, PID-based detection strategies can reliably detect fluence anomalies of ≥5% in ∼1 mm2 areas and ≥2% in ∼20 mm2 areas. Conclusions: The ability to detect small dose differences (≤2%) depends strongly on the level of background noise. This in turn depends on the accuracy of image registration, the quality of the reference image, and field properties. The longer term aim of this work is to develop accurate and reliable methods of detecting IMRT delivery errors and variations. The ability to resolve small anomalies will allow the accuracy of advanced treatment techniques, such as image guided, adaptive, and arc therapies, to be quantified. PMID:22894421

  11. Advanced Fire Detector for Space Applications

    NASA Technical Reports Server (NTRS)

    Kutzner, Joerg

    2012-01-01

    A document discusses an optical carbon monoxide sensor for early fire detection. During the sensor development, a concept was implemented to allow reliable carbon monoxide detection in the presence of interfering absorption signals. Methane interference is present in the operating wavelength range of the developed prototype sensor for carbon monoxide detection. The operating parameters of the prototype sensor have been optimized so that interference with methane is minimized. In addition, simultaneous measurement of methane is implemented, and the instrument automatically corrects the carbon monoxide signal at high methane concentrations. This is possible because VCSELs (vertical cavity surface emitting lasers) with extended current tuning capabilities are implemented in the optical device. The tuning capabilities of these new laser sources are sufficient to cover the wavelength range of several absorption lines. The delivered carbon monoxide sensor (COMA 1) reliably measures low carbon monoxide levels even in the presence of high methane signals. The signal bleed-over is determined during system calibration and is then accounted for in the system parameters. The sensor reports carbon monoxide concentrations reliably for (interfering) methane concentrations up to several thousand parts per million.

  12. Test-retest reliability and minimal detectable change of two simplified 3-point balance measures in patients with stroke.

    PubMed

    Chen, Yi-Miau; Huang, Yi-Jing; Huang, Chien-Yu; Lin, Gong-Hong; Liaw, Lih-Jiun; Lee, Shih-Chieh; Hsieh, Ching-Lin

    2017-10-01

    The 3-point Berg Balance Scale (BBS-3P) and 3-point Postural Assessment Scale for Stroke Patients (PASS-3P) were simplified from the BBS and PASS to overcome the complex scoring systems. The BBS-3P and PASS-3P were more feasible in busy clinical practice and showed similarly sound validity and responsiveness to the original measures. However, the reliability of the BBS-3P and PASS-3P is unknown limiting their utility and the interpretability of scores. We aimed to examine the test-retest reliability and minimal detectable change (MDC) of the BBS-3P and PASS-3P in patients with stroke. Cross-sectional study. The rehabilitation departments of a medical center and a community hospital. A total of 51 chronic stroke patients (64.7% male). Both balance measures were administered twice 7 days apart. The test-retest reliability of both the BBS-3P and PASS-3P were examined by intraclass correlation coefficients (ICC). The MDC and its percentage over the total score (MDC%) of each measure was calculated for examining the random measurement errors. The ICC values of the BBS-3P and PASS-3P were 0.99 and 0.97, respectively. The MDC% (MDC) of the BBS-3P and PASS-3P were 9.1% (5.1 points) and 8.4% (3.0 points), respectively, indicating that both measures had small and acceptable random measurement errors. Our results showed that both the BBS-3P and the PASS-3P had good test-retest reliability, with small and acceptable random measurement error. These two simplified 3-level balance measures can provide reliable results over time. Our findings support the repeated administration of the BBS-3P and PASS-3P to monitor the balance of patients with stroke. The MDC values can help clinicians and researchers interpret the change scores more precisely.

  13. High inter-rater reliability, agreement, and convergent validity of Constant score in patients with clavicle fractures.

    PubMed

    Ban, Ilija; Troelsen, Anders; Kristensen, Morten Tange

    2016-10-01

    The Constant score (CS) has been the primary endpoint in most studies on clavicle fractures. However, the CS was not developed to assess patients with clavicle fractures. Our aim was to examine inter-rater reliability and agreement of the CS in patients with clavicle fractures. The secondary aim was to estimate the correlation between the CS and the Disabilities of the Arm, Shoulder and Hand score and the internal consistency of the 2 scores. On the basis of sample sizing, 36 patients (31 male and 5 female patients; mean age, 41.3 years) with clavicle fractures underwent standardized CS assessment at a mean of 6.8 weeks (SD, 1.0 weeks) after injury. Reliability and agreement of the CS were determined by 2 raters. The interclass correlation coefficient (ICC2,1), standard error of measurement, minimal detectable change, Cronbach α coefficient, and Pearson correlation coefficient were estimated. Inter-rater reliability of the total CS was excellent (interclass correlation coefficient, 0.94; 95% confidence interval, 0.88-0.97), with no systematic difference between the 2 raters (P = .75). The standard error of measurement (measurement error at the group level) was 4.9, whereas the minimal detectable change (smallest change needed to indicate a real change for an individual) was 13.6 CS points. The internal consistency of the 10 CS items was good, with a Cronbach α of .85, and we found a strong correlation (r = -0.92) between the CS and Disabilities of the Arm, Shoulder and Hand score. The CS was found to be reliable for assessing patients with clavicle fractures, especially at the group level. With high inter-rater reliability and agreement, in addition to good internal consistency, the standardized CS used in this study can be used for comparison of results from different settings. Copyright © 2016 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  14. Rear-end vision-based collision detection system for motorcyclists

    NASA Astrophysics Data System (ADS)

    Muzammel, Muhammad; Yusoff, Mohd Zuki; Meriaudeau, Fabrice

    2017-05-01

    In many countries, the motorcyclist fatality rate is much higher than that of other vehicle drivers. Among many other factors, motorcycle rear-end collisions are also contributing to these biker fatalities. To increase the safety of motorcyclists and minimize their road fatalities, this paper introduces a vision-based rear-end collision detection system. The binary road detection scheme contributes significantly to reduce the negative false detections and helps to achieve reliable results even though shadows and different lane markers are present on the road. The methodology is based on Harris corner detection and Hough transform. To validate this methodology, two types of dataset are used: (1) self-recorded datasets (obtained by placing a camera at the rear end of a motorcycle) and (2) online datasets (recorded by placing a camera at the front of a car). This method achieved 95.1% accuracy for the self-recorded dataset and gives reliable results for the rear-end vehicle detections under different road scenarios. This technique also performs better for the online car datasets. The proposed technique's high detection accuracy using a monocular vision camera coupled with its low computational complexity makes it a suitable candidate for a motorbike rear-end collision detection system.

  15. Fiber optic distributed chemical sensor for the real time detection of hydrocarbon fuel leaks

    NASA Astrophysics Data System (ADS)

    Mendoza, Edgar; Kempen, C.; Esterkin, Yan; Sun, Sunjian

    2015-09-01

    With the increase worldwide demand for hydrocarbon fuels and the vast development of new fuel production and delivery infrastructure installations around the world, there is a growing need for reliable hydrocarbon fuel leak detection technologies to provide safety and reduce environmental risks. Hydrocarbon leaks (gas or liquid) pose an extreme danger and need to be detected very quickly to avoid potential disasters. Gas leaks have the greatest potential for causing damage due to the explosion risk from the dispersion of gas clouds. This paper describes progress towards the development of a fast response, high sensitivity, distributed fiber optic fuel leak detection (HySense™) system based on the use of an optical fiber that uses a hydrocarbon sensitive fluorescent coating to detect the presence of fuel leaks present in close proximity along the length of the sensor fiber. The HySense™ system operates in two modes, leak detection and leak localization, and will trigger an alarm within seconds of exposure contact. The fast and accurate response of the sensor provides reliable fluid leak detection for pipelines, storage tanks, airports, pumps, and valves to detect and minimize any potential catastrophic damage.

  16. A Fast, Reliable, and Sensitive Method for Detection and Quantification of Listeria monocytogenes and Escherichia coli O157:H7 in Ready-to-Eat Fresh-Cut Products by MPN-qPCR

    PubMed Central

    Russo, Pasquale; Botticella, Giuseppe; Capozzi, Vittorio; Massa, Salvatore; Spano, Giuseppe; Beneduce, Luciano

    2014-01-01

    In the present work we developed a MPN quantitative real-time PCR (MPN-qPCR) method for a fast and reliable detection and quantification of Listeria monocytogenes and Escherichia coli O157:H7 in minimally processed vegetables. In order to validate the proposed technique, the results were compared with conventional MPN followed by phenotypic and biochemical assays methods. When L. monocytogenes and E. coli O157:H7 were artificially inoculated in fresh-cut vegetables, a concentration as low as 1 CFU g−1 could be detected in 48 hours for both pathogens. qPCR alone allowed a limit of detection of 101 CFU g−1 after 2 hours of enrichment for L. monocytogenes and E. coli O157:H7. Since minimally processed ready-to-eat vegetables are characterized by very short shelf life, our method can potentially address the consistent reduction of time for microbial analysis, allowing a better management of quality control. Moreover, the occurrences of both pathogenic bacteria in mixed salad samples and fresh-cut melons were monitored in two production plants from the receipt of the raw materials to the early stages of shelf life. No sample was found to be contaminated by L. monocytogenes. One sample of raw mixed salad was found positive to an H7 enterohemorrhagic serotype. PMID:24949460

  17. Minimal detectable change of the Personal and Social Performance scale in individuals with schizophrenia.

    PubMed

    Lee, Shu-Chun; Tang, Shih-Fen; Lu, Wen-Shian; Huang, Sheau-Ling; Deng, Nai-Yu; Lue, Wen-Chyn; Hsieh, Ching-Lin

    2016-12-30

    The minimal detectable change (MDC) of the Personal and Social Performance scale (PSP) has not yet been investigated, limiting its utility in data interpretation. The purpose of this study was to determine the MDCs of the PSP administered by the same rater or different raters in individuals with schizophrenia. Participants with schizophrenia were recruited from two psychiatric community rehabilitation centers to complete the PSP assessments twice, 2 weeks apart, by the same rater or 2 different raters. MDC values were calculated from the coefficients of intra- and inter-rater reliability (i.e., intraclass correlation coefficients). Forty patients (mean age 36.9 years, SD 9.7) from one center participated in the intra-rater reliability study. Another 40 patients (mean age 44.3 years, SD 11.1) from the other center participated in the inter-rater study. The MDCs (MDC%) of the PSP were 10.7 (17.1%) for the same rater and 16.2 (24.1%) for different raters. The MDCs of the PSP appeared appropriate for clinical trials aiming to determine whether a real change in social functioning has occurred in people with schizophrenia. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  18. Reliability, Validity, and Minimal Detectable Change of Balance Evaluation Systems Test and Its Short Versions in Older Cancer Survivors: A Pilot Study.

    PubMed

    Huang, Min H; Miller, Kara; Smith, Kristin; Fredrickson, Kayle; Shilling, Tracy

    2016-01-01

    Cancer is primarily a disease of older adults. About 77% of all cancers are diagnosed in persons aged 55 years and older. Cancer and its treatment can cause diverse sequelae impacting body systems underlying balance control. No study has examined the psychometric properties of balance assessment tools in older cancer survivors, presenting a significant challenge in the selection of outcome measures for clinicians treating this fast-growing population. This study aimed to determine the reliability, validity, and minimal detectable change (MDC) of the Balance Evaluation System Test (BESTest), Mini-Balance Evaluation Systems Test (Mini-BESTest), and Brief-Balance Evaluation Systems Test (Brief-BESTest) in community-dwelling older cancer survivors. This study was a cross-sectional design. Twenty breast and 8 prostate cancer survivors participated [age (SD) = 68.4 (8.13) years]. The BESTest and Activity-specific Balance Confidence (ABC) Scale were administered during the first session. Scores of Mini-BESTest and Brief-BESTest were extracted on the basis of the scores of BESTest. The BESTest was repeated within 1 to 2 weeks by the same rater to determine the test-retest reliability. For the analysis of the inter-rater reliability, 21 participants were randomly selected to be evaluated by 2 raters. A primary rater administered the test. The 2 raters independently and concurrently scored the performance of the participants. Each rater recorded the ratings separately on the scoring sheet. No discussion among the raters was allowed throughout the testing. Intraclass correlation coefficients (ICCs), standard error of measurement, minimal detectable change (MDC), and Bland-Altman plots were calculated. Concurrent validity of these balance tests with the ABC Scale was examined using the Spearman correlation. The BESTest, Mini-BESTest, and Brief-BESTest had high test-retest (ICC = 0.90-0.94) and interrater reliability (ICC = 0.86-0.96), small standard error of measurement (0.86-2.47 points), and MDC (2.39-6.86 points). The Bland-Altman plot revealed no systematic errors. The scores of BESTest, Mini-BEST, and Brief-BEST were correlated significantly with those of ABC Scale (P < .01), supporting their concurrent validity. The BESTest, Mini-BESTest, and Brief-BESTest showed high interrater and test-retest reliability, and excellent concurrent validity with the ABC Scale for community-dwelling cancer survivors aged 55 years and older who had completed cancer treatments for at least 3 months. Future studies are necessary to determine the predictive values for determining fall risks using balance assessment tools in older cancer survivors. Clinicians can utilize the BESTest and its short versions to evaluate balance problems in community-dwelling older cancer survivors and apply the established MDC to assess the intervention outcomes.

  19. Reliability, validity and minimal detectable change of computerized respiratory sounds in patients with chronic obstructive pulmonary disease.

    PubMed

    Oliveira, Ana; Lage, Susan; Rodrigues, João; Marques, Alda

    2017-11-17

    Computerized respiratory sounds (CRS) are closely related to the movement of air within the tracheobronchial tree and are promising outcome measures in patients with chronic obstructive pulmonary disease (COPD). However, CRS measurement properties have been poorly tested. The aim of this study was to assess the reliability, validity and the minimal detectable changes (MDC) of CRS in patients with stable COPD. Fifty patients (36♂, 67.26 ± 9.31y, FEV 1 49.52 ± 19.67%predicted) were enrolled. CRS were recorded simultaneously at seven anatomic locations (trachea; right and left anterior, lateral and posterior chest). The number of crackles, wheeze occupation rate, median frequency (F50) and maximum intensity (Imax) were processed using validated algorithms. Within-day and between-days reliability, criterion and construct validity, validity to predict exacerbations and MDC were established. CRS presented moderate-to-excellent within-day reliability (ICC 1,3  ≥ 0.51; P < .05) and moderate-to-good between-days reliability (ICC 1,2  ≥ 0.47; P < .05) for most locations. Negligible-to-moderate correlations with FEV 1 %predicted were found (-0.53 < r s  < -0.28; P < .05), and the inspiratory number of crackles were the best discriminator between mild-to-moderate and severe-to-very severe airflow limitations (area under the curve >0.78). CRS correlated poorly with patient-reported outcomes (r s  < 0.48; P < .05) and did not predict exacerbations. Inspiratory number of crackles at posterior right chest, inspiratory F50 at trachea and anterior left chest and expiratory Imax at anterior right chest were simultaneously reliable and valid, and their MDC were 2.41, 55.27, 29.55 and 3.98, respectively. CRS are reliable and valid. Their use, integrated with other clinical and patient-reported measures, may fill the gap of assessing small airways and contribute toward a patient's comprehensive evaluation. © 2017 John Wiley & Sons Ltd.

  20. Correlation Study Of Diffenrential Skin Temperatures (DST) For Ovulation Detection Using Infra-Red Thermography

    NASA Astrophysics Data System (ADS)

    Rao, K. H. S.; Shah, A. v.; Ruedi, B.

    1982-11-01

    The importance of ovulation time detection in the Practice of Natural Birth Control (NBC) as a contraceptive tool, and for natural/artificial insemination among women having the problem of in-fertility, is well known. The simple Basal Body Temperature (BBT) method of ovulation detection is so far unreliable. A newly proposed Differential Skin Temperature (DST) method may help minimize disturbing physiological effects and improve reliability. This paper explains preliminary results of a detailed correlative study on the DST method, using Infra-Red Thermography (IRT) imaging, and computer analysis techniques. Results obtained with five healthy, normally menstruating women volunteers will be given.

  1. Minimal methylation classifier (MIMIC): A novel method for derivation and rapid diagnostic detection of disease-associated DNA methylation signatures.

    PubMed

    Schwalbe, E C; Hicks, D; Rafiee, G; Bashton, M; Gohlke, H; Enshaei, A; Potluri, S; Matthiesen, J; Mather, M; Taleongpong, P; Chaston, R; Silmon, A; Curtis, A; Lindsey, J C; Crosier, S; Smith, A J; Goschzik, T; Doz, F; Rutkowski, S; Lannering, B; Pietsch, T; Bailey, S; Williamson, D; Clifford, S C

    2017-10-18

    Rapid and reliable detection of disease-associated DNA methylation patterns has major potential to advance molecular diagnostics and underpin research investigations. We describe the development and validation of minimal methylation classifier (MIMIC), combining CpG signature design from genome-wide datasets, multiplex-PCR and detection by single-base extension and MALDI-TOF mass spectrometry, in a novel method to assess multi-locus DNA methylation profiles within routine clinically-applicable assays. We illustrate the application of MIMIC to successfully identify the methylation-dependent diagnostic molecular subgroups of medulloblastoma (the most common malignant childhood brain tumour), using scant/low-quality samples remaining from the most recently completed pan-European medulloblastoma clinical trial, refractory to analysis by conventional genome-wide DNA methylation analysis. Using this approach, we identify critical DNA methylation patterns from previously inaccessible cohorts, and reveal novel survival differences between the medulloblastoma disease subgroups with significant potential for clinical exploitation.

  2. The Berg Balance Scale has high intra- and inter-rater reliability but absolute reliability varies across the scale: a systematic review.

    PubMed

    Downs, Stephen; Marquez, Jodie; Chiarelli, Pauline

    2013-06-01

    What is the intra-rater and inter-rater relative reliability of the Berg Balance Scale? What is the absolute reliability of the Berg Balance Scale? Does the absolute reliability of the Berg Balance Scale vary across the scale? Systematic review with meta-analysis of reliability studies. Any clinical population that has undergone assessment with the Berg Balance Scale. Relative intra-rater reliability, relative inter-rater reliability, and absolute reliability. Eleven studies involving 668 participants were included in the review. The relative intrarater reliability of the Berg Balance Scale was high, with a pooled estimate of 0.98 (95% CI 0.97 to 0.99). Relative inter-rater reliability was also high, with a pooled estimate of 0.97 (95% CI 0.96 to 0.98). A ceiling effect of the Berg Balance Scale was evident for some participants. In the analysis of absolute reliability, all of the relevant studies had an average score of 20 or above on the 0 to 56 point Berg Balance Scale. The absolute reliability across this part of the scale, as measured by the minimal detectable change with 95% confidence, varied between 2.8 points and 6.6 points. The Berg Balance Scale has a higher absolute reliability when close to 56 points due to the ceiling effect. We identified no data that estimated the absolute reliability of the Berg Balance Scale among participants with a mean score below 20 out of 56. The Berg Balance Scale has acceptable reliability, although it might not detect modest, clinically important changes in balance in individual subjects. The review was only able to comment on the absolute reliability of the Berg Balance Scale among people with moderately poor to normal balance. Copyright © 2013 Australian Physiotherapy Association. Published by .. All rights reserved.

  3. Minimum Control Requirements for Advanced Life Support Systems

    NASA Technical Reports Server (NTRS)

    Boulange, Richard; Jones, Harry; Jones, Harry

    2002-01-01

    Advanced control technologies are not necessary for the safe, reliable and continuous operation of Advanced Life Support (ALS) systems. ALS systems can and are adequately controlled by simple, reliable, low-level methodologies and algorithms. The automation provided by advanced control technologies is claimed to decrease system mass and necessary crew time by reducing buffer size and minimizing crew involvement. In truth, these approaches increase control system complexity without clearly demonstrating an increase in reliability across the ALS system. Unless these systems are as reliable as the hardware they control, there is no savings to be had. A baseline ALS system is presented with the minimal control system required for its continuous safe reliable operation. This baseline control system uses simple algorithms and scheduling methodologies and relies on human intervention only in the event of failure of the redundant backup equipment. This ALS system architecture is designed for reliable operation, with minimal components and minimal control system complexity. The fundamental design precept followed is "If it isn't there, it can't fail".

  4. Combined Bisulfite Restriction Analysis for brain tissue identification.

    PubMed

    Samsuwan, Jarunya; Muangsub, Tachapol; Yanatatsaneejit, Pattamawadee; Mutirangura, Apiwat; Kitkumthorn, Nakarin

    2018-05-01

    According to the tissue-specific methylation database (doi: 10.1016/j.gene.2014.09.060), methylation at CpG locus cg03096975 in EML2 has been preliminarily proven to be specific to brain tissue. In this study, we enlarged sample size and developed a technique for identifying brain tissue in aged samples. Combined Bisulfite Restriction Analysis-for EML2 (COBRA-EML2) technique was established and validated in various organ samples obtained from 108 autopsies. In addition, this technique was also tested for its reliability, minimal DNA concentration detected, and use in aged samples and in samples obtained from specific brain compartments and spinal cord. COBRA-EML2 displayed 100% sensitivity and specificity for distinguishing brain tissue from other tissues, showed high reliability, was capable of detecting minimal DNA concentration (0.015ng/μl), could be used for identifying brain tissue in aged samples. In summary, COBRA-EML2 is a technique to identify brain tissue. This analysis is useful in criminal cases since it can identify the vital organ tissues from small samples acquired from criminal scenes. The results from this analysis can be counted as a medical and forensic marker supporting criminal investigations, and as one of the evidences in court rulings. Copyright © 2018 Elsevier B.V. All rights reserved.

  5. Clinical feasibility test on a minimally invasive laser therapy system in microsurgery of nerves.

    PubMed

    Mack, K F; Leinung, M; Stieve, M; Lenarz, T; Schwab, B

    2008-01-01

    The clinical feasibility test described here evaluates the basis for a laser therapy system that enables tumour tissue to be separated from nerves in a minimally invasive manner. It was first investigated whether, using an Er:YAG laser, laser-induced nerve (specifically, facial nerve) responses in the rabbit in vivo can be reliably detected with the hitherto standard monitoring techniques. Peripherally recordable neuromuscular signals (i.e. compound action potentials, CAPs) were used to monitor nerve function and to establish a feedback loop. The first occurrence of laser-evoked CAPs was taken as the criterion for deciding when to switch off the laser. When drawing up criteria governing the control and termination of the laser application, the priority was the maintenance of nerve function. Five needle-electrode arrays specially developed for this purpose, each with a miniature preamplifier, were then placed into the facial musculature instead of single-needle electrodes. The system was tested in vivo under realistic surgical conditions (i.e. facial-nerve surgery in the rabbit). This modified multi-channel electromyography (EMG) system enabled laser-evoked CAPs to be detected that have amplitudes 10 times smaller than those picked up by commercially available systems. This optimization, and the connection of the neuromuscular unit with the Er:YAG laser via the electrode array to create a feedback loop, were designed to make it possible to maintain online control of the laser ablation process in the vicinity of neuronal tissue, thus ensuring that tissue excision is both reliable and does not affect function. Our results open up new possibilities in minimally invasive surgery near neural structures.

  6. CARS technique for geological exploration of hydrocarbons deposits

    NASA Astrophysics Data System (ADS)

    Zhevlakov, A. P.; Bespalov, Victor; Elizarov, V. V.; Grishkanich, A. S.; Kascheev, S. V.; Makarov, E. A.; Bogoslovsky, S. A.; Il'inskiy, A. A.

    2014-10-01

    We developed a Raman lidar with ultraspectral resolution for automatic airborne monitoring of pipeline leaks and for oil and gas exploration. Experiments were carried out under the CARS circuit. Minimal concentrations of 200 ppb of heavy hydrocarbon gas have been remotely measured in laboratory tests. Test flights indicate that a sensitivity of 6 ppm for methane and 2 ppm for hydrogen sulfide has been reached for leakage detection. As estimations have shown the reliability of heavy hydrocarbon gas detection by the integration method of seismic prospecting and remote laser sensing in CARS circuit can exceed 80%.

  7. Autism detection in early childhood (ADEC): reliability and validity data for a Level 2 screening tool for autistic disorder.

    PubMed

    Nah, Yong-Hwee; Young, Robyn L; Brewer, Neil; Berlingeri, Genna

    2014-03-01

    The Autism Detection in Early Childhood (ADEC; Young, 2007) was developed as a Level 2 clinician-administered autistic disorder (AD) screening tool that was time-efficient, suitable for children under 3 years, easy to administer, and suitable for persons with minimal training and experience with AD. A best estimate clinical Diagnostic and Statistical Manual of Mental Disorders (4th ed., text rev.; DSM-IV-TR; American Psychiatric Association, 2000) diagnosis of AD was made for 70 children using all available information and assessment results, except for the ADEC data. A screening study compared these children on the ADEC with 57 children with other developmental disorders and 64 typically developing children. Results indicated high internal consistency (α = .91). Interrater reliability and test-retest reliability of the ADEC were also adequate. ADEC scores reliably discriminated different diagnostic groups after controlling for nonverbal IQ and Vineland Adaptive Behavior Composite scores. Construct validity (using exploratory factor analysis) and concurrent validity using performance on the Autism Diagnostic Observation Schedule (Lord et al., 2000), the Autism Diagnostic Interview-Revised (Le Couteur, Lord, & Rutter, 2003), and DSM-IV-TR criteria were also demonstrated. Signal detection analysis identified the optimal ADEC cutoff score, with the ADEC identifying all children who had an AD (N = 70, sensitivity = 1.0) but overincluding children with other disabilities (N = 13, specificity ranging from .74 to .90). Together, the reliability and validity data indicate that the ADEC has potential to be established as a suitable and efficient screening tool for infants with AD. 2014 APA

  8. Test-Retest Reliability and Minimal Detectable Change of Randomized Dichotic Digits in Learning-Disabled Children: Implications for Dichotic Listening Training.

    PubMed

    Mahdavi, Mohammad Ebrahim; Pourbakht, Akram; Parand, Akram; Jalaie, Shohreh

    2018-03-01

    Evaluation of dichotic listening to digits is a common part of many studies for diagnosis and managing auditory processing disorders in children. Previous researchers have verified test-retest relative reliability of dichotic digits results in normal children and adults. However, detecting intervention-related changes in the ear scores after dichotic listening training requires information regarding trial-to-trial typical variation of individual ear scores that is estimated using indices of absolute reliability. Previous studies have not addressed absolute reliability of dichotic listening results. To compare the results of the Persian randomized dichotic digits test (PRDDT) and its relative and absolute indices of reliability between typical achieving (TA) and learning-disabled (LD) children. A repeated measures observational study. Fifteen LD children were recruited from a previously performed study with age range of 7-12 yr. The control group consisted of 15 TA schoolchildren with age range of 8-11 yr. The Persian randomized dichotic digits test was administered on the children under free recall condition in two test sessions 7-12 days apart. We compared the average of the ear scores and ear advantage between TA and LD children. Relative indices of reliability included Pearson's correlation and intraclass correlation (ICC 2,1 ) coefficients and absolute reliability was evaluated by calculation of standard error of measurement (SEM) and minimal detectable change (MDC) using the raw ear scores. The Pearson correlation coefficient indicated that in both groups of children the ear scores of test and retest sessions were strongly and positively (greater than +0.8) correlated. The ear scores showed excellent ICC coefficient of consistency (0.78-0.82) and fair to excellent ICC coefficient of absolute agreement (0.62-0.74) in TA children and excellent ICC coefficients of consistency and absolute agreement in LD children (0.76-0.87). SEM and SEM% of the ear scores in TA children were 1.46 and 1.44% for the right ear and 4.68 and 5.47% for the left ear. SEM and SEM% of the ear scores in LD children were 4.55 and 5.88% for the right ear to 7.56 and 12.81% for the left ear. MDC and MDC% of the ear scores in TA children varied from 4.03 and 3.99% for the right ear to 12.93 and 15.13% for the left ear. MDC and MDC% of the ear scores in LD children varied from 12.57 and 16.25% for the right ear to 20.89 and 35.39% for the left ear. The LD children indicated test-retest relative reliability as high as TA children in the ear scores measured by PRDDT. However, within-subject variations of the ear scores calculated by indices of absolute reliability were considerably higher in LD children versus TA children. The results of the current study could have implications for detecting real training-related changes in the ear scores. American Academy of Audiology

  9. Rapid detection of potyviruses from crude plant extracts.

    PubMed

    Silva, Gonçalo; Oyekanmi, Joshua; Nkere, Chukwuemeka K; Bömer, Moritz; Kumar, P Lava; Seal, Susan E

    2018-04-01

    Potyviruses (genus Potyvirus; family Potyviridae) are widely distributed and represent one of the most economically important genera of plant viruses. Therefore, their accurate detection is a key factor in developing efficient control strategies. However, this can sometimes be problematic particularly in plant species containing high amounts of polysaccharides and polyphenols such as yam (Dioscorea spp.). Here, we report the development of a reliable, rapid and cost-effective detection method for the two most important potyviruses infecting yam based on reverse transcription-recombinase polymerase amplification (RT-RPA). The developed method, named 'Direct RT-RPA', detects each target virus directly from plant leaf extracts prepared with a simple and inexpensive extraction method avoiding laborious extraction of high-quality RNA. Direct RT-RPA enables the detection of virus-positive samples in under 30 min at a single low operation temperature (37 °C) without the need for any expensive instrumentation. The Direct RT-RPA tests constitute robust, accurate, sensitive and quick methods for detection of potyviruses from recalcitrant plant species. The minimal sample preparation requirements and the possibility of storing RPA reagents without cold chain storage, allow Direct RT-RPA to be adopted in minimally equipped laboratories and with potential use in plant clinic laboratories and seed certification facilities worldwide. Copyright © 2018 The Authors. Published by Elsevier Inc. All rights reserved.

  10. A new method of scoring radiographic change in rheumatoid arthritis.

    PubMed

    Rau, R; Wassenberg, S; Herborn, G; Stucki, G; Gebler, A

    1998-11-01

    To test the reliability and to define the minimal detectable change of a new radiographic scoring method in rheumatoid arthritis (RA). Following the recommendations of an expert panel a new radiographic scoring method was defined. It scores 38 joints [all proximal interphalangeal (PIP) and metacarpophalangeal joints, 4 sites in the wrists, IP of the great toes, and metatarsophalangeals 2 to 5], regarding only the amount of joint surface destruction on a 0 to 5 scale for each joint. Each grade represents 20% of joint surface destruction. The method was tested by 5 readers on a set of 7 serial radiographs of hands and forefeet of 20 patients with progressive and destructive RA. Analysis of variance was performed, as it provides the best information about the capability of a method to detect real change and to define its sensitivity according to the minimal detectable change. Analysis of variance proved a high probability that the readers found real change with a ratio of intrapatient to intrareader standard deviation of 2.6. It also confirmed that one reader could detect a change of 3.5% of the total score with a probability of 95% and that different readers agreed upon a change of 4.6%. Inexperienced readers performed with comparable results to experienced readers. The time required for the reading averaged less than 10 minutes for the scoring of one set. The new radiographic scoring method proved to be reliable, precise, and easy to learn, with reasonable cost. Compared to published data, it may provide better results than the widely used Larsen score. These features favor our new method for use in clinical trials and in longterm observational studies in RA.

  11. Unreliable Yet Still Replicable: A Comment on LeBel and Paunonen (2011)

    PubMed Central

    De Schryver, Maarten; Hughes, Sean; Rosseel, Yves; De Houwer, Jan

    2016-01-01

    Lebel and Paunonen (2011) highlight that despite their importance and popularity in both theoretical and applied research, many implicit measures continue to be plagued by a persistent and troublesome issue—low reliability. In their paper, they offer a conceptual analysis of the relationship between reliability, power and replicability, and then provide a series of recommendations for researchers interested in using implicit measures in an experimental setting. At the core of their account is the idea that reliability can be equated with statistical power, such that “lower levels of reliability are associated with decreasing probabilities of detecting a statistically significant effect, given one exists in the population” (p. 573). They also take the additional step of equating reliability and replicability. In our commentary, we draw attention to the fact that there is no direct, fixed or one-to-one relation between reliability and power or replicability. More specifically, we argue that when adopting an experimental (rather than a correlational) approach, researchers strive to minimize inter-individual variation, which has a direct impact on sample based reliability estimates. We evaluate the strengths and weaknesses of the LeBel and Paunonen's recommendations and refine them where appropriate. PMID:26793150

  12. Which is the most useful patient-reported outcome in femoroacetabular impingement? Test-retest reliability of six questionnaires.

    PubMed

    Hinman, Rana S; Dobson, Fiona; Takla, Amir; O'Donnell, John; Bennell, Kim L

    2014-03-01

    The most reliable patient-reported outcomes (PROs) for people with femoroacetabular impingement (FAI) is unknown because there have been no direct comparisons of questionnaires. Thus, the aim was to evaluate the test-retest reliability of six existing PROs in a single cohort of young active people with hip/groin pain consistent with a clinical diagnosis of FAI. Young adults with clinical FAI completed six PRO questionnaires on two occasions, 1-2 weeks apart. The PROs were modified Harris Hip Score, Hip dysfunction and Osteoarthritis Score, Hip Outcome Score, Non-Arthritic Hip Score, International Hip Outcome Tool, Copenhagen Hip and Groin Outcome Score. 30 young adults (mean age 24 years, SD 4 years, range 18-30 years; 15 men) with stable symptoms participated. Intraclass correlation coefficient(3,1) values ranged from 0.73 to 0.93 (95% CI 0.38 to 0.98) indicating that most questionnaires reached minimal reliability benchmarks. Measurement error at the individual level was quite large for most questionnaires (minimal detectable change (MDC95) 12.4-35.6, 95% CI 8.7 to 54.0). In contrast, measurement error at the group level was quite small for most questionnaires (MDC95 2.2-7.3, 95% CI 1.6 to 11). The majority of the questionnaires were reliable and precise enough for use at the group level. Samples of only 23-30 individuals were required to achieve acceptable measurement variation at the group level. Further direct comparisons of these questionnaires are required to assess other measurement properties such as validity, responsiveness and meaningful change in young people with FAI.

  13. Reliability of levator scapulae index in subjects with and without scapular downward rotation syndrome.

    PubMed

    Lee, Ji-Hyun; Cynn, Heon-Seock; Choi, Woo-Jeong; Jeong, Hyo-Jung; Yoon, Tae-Lim

    2016-05-01

    The objective of this study was to introduce levator scapulae (LS) measurement using a caliper and the levator scapulae index (LSI) and to investigate intra- and interrater reliability of the LSI in subjects with and without scapular downward rotation syndrome (SDRS). Two raters measured LS length twice in 38 subjects (19 with SDRS and 19 without SDRS). For reliability testing, intraclass correlation coefficients (ICCs), standard error of measurement (SEM), and minimal detectable change (MDC) were calculated. Intrarater reliability analysis resulted with ICCs ranging from 0.94 to 0.98 in subjects with SDRS and 0.96 to 0.98 in subjects without SDRS. These results represented that intrarater reliability in both groups were excellent for measuring LS length with the LSI. Interrater reliability was good (ICC: 0.82) in subjects with SDRS; however, interrater reliability was moderate (ICC: 0.75) in subjects without SDRS. Additionally, SEM and MDC were 0.13% and 0.36% in subjects with SDRS and 0.35% and 0.97% in subjects without SDRS. In subjects with SDRS, low dispersion of the measurement errors and MDC were shown. This study suggested that the LSI is a reliable method to measure LS length and is more reliable for subjects with SDRS. Copyright © 2015 Elsevier Ltd. All rights reserved.

  14. Interrater and Intrarater Reliability of the Balance Computerized Adaptive Test in Patients With Stroke.

    PubMed

    Chiang, Hsin-Yu; Lu, Wen-Shian; Yu, Wan-Hui; Hsueh, I-Ping; Hsieh, Ching-Lin

    2018-04-11

    To examine the interrater and intrarater reliability of the Balance Computerized Adaptive Test (Balance CAT) in patients with chronic stroke having a wide range of balance functions. Repeated assessments design (1wk apart). Seven teaching hospitals. A pooled sample (N=102) including 2 independent groups of outpatients (n=50 for the interrater reliability study; n=52 for the intrarater reliability study) with chronic stroke. Not applicable. Balance CAT. For the interrater reliability study, the values of intraclass correlation coefficient, minimal detectable change (MDC), and percentage of MDC (MDC%) for the Balance CAT were .84, 1.90, and 31.0%, respectively. For the intrarater reliability study, the values of intraclass correlation coefficient, MDC, and MDC% ranged from .89 to .91, from 1.14 to 1.26, and from 17.1% to 18.6%, respectively. The Balance CAT showed sufficient intrarater reliability in patients with chronic stroke having balance functions ranging from sitting with support to independent walking. Although the Balance CAT may have good interrater reliability, we found substantial random measurement error between different raters. Accordingly, if the Balance CAT is used as an outcome measure in clinical or research settings, same raters are suggested over different time points to ensure reliable assessments. Copyright © 2018 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  15. Validity and reliability of the de Morton Mobility Index in the subacute hospital setting in a geriatric evaluation and management population.

    PubMed

    de Morton, Natalie A; Lane, Kylie

    2010-11-01

    To investigate the clinimetric properties of the de Morton Mobility Index (DEMMI) in a Geriatric Evaluation and Management (GEM) population. A longitudinal validation study (n = 100) and inter-rater reliability study (n = 29) in a GEM population. Consecutive patients admitted to a GEM rehabilitation ward were eligible for inclusion. At hospital admission and discharge, a physical therapist assessed patients with physical performance instruments that included the 6-metre walk test, step test, Clinical Test of Sensory Organization and Balance, Timed Up and Go test, 6-minute walk test and the DEMMI. Consecutively eligible patients were included in an inter-rater reliability study between physical therapists. DEMMI admission scores were normally distributed (mean 30.2, standard deviation 16.7) and other activity limitation instruments had either a floor or a ceiling effect. Evidence of convergent, discriminant and known groups validity for the DEMMI were obtained. The minimal detectable change with 90% confidence was 10.5 (95% confidence interval 6.1-17.9) points and the minimally clinically important difference was 8.4 points on the 100-point interval DEMMI scale. The DEMMI provides clinicians with an accurate and valid method of measuring mobility for geriatric patients in the subacute hospital setting.

  16. Detection of Rooftop Cooling Unit Faults Based on Electrical Measurements

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Armstrong, Peter R.; Laughman, C R.; Leeb, S B.

    Non-intrusive load monitoring (NILM) is accomplished by sampling voltage and current at high rates and reducing the resulting start transients or harmonic contents to concise ''signatures''. Changes in these signatures can be used to detect, and in many cases directly diagnose, equipment and component faults associated with roof-top cooling units. Use of the NILM for fault detection and diagnosis (FDD) is important because (1) it complements other FDD schemes that are based on thermo-fluid sensors and analyses and (2) it is minimally intrusive (one measuring point in the relatively protected confines of the control panel) and therefore inherently reliable. Thismore » paper describes changes in the power signatures of fans and compressors that were found, experimentally and theoretically, to be useful for fault detection.« less

  17. IVGTT-based simple assessment of glucose tolerance in the Zucker fatty rat: Validation against minimal models.

    PubMed

    Morettini, Micaela; Faelli, Emanuela; Perasso, Luisa; Fioretti, Sandro; Burattini, Laura; Ruggeri, Piero; Di Nardo, Francesco

    2017-01-01

    For the assessment of glucose tolerance from IVGTT data in Zucker rat, minimal model methodology is reliable but time- and money-consuming. This study aimed to validate for the first time in Zucker rat, simple surrogate indexes of insulin sensitivity and secretion against the glucose-minimal-model insulin sensitivity index (SI) and against first- (Φ1) and second-phase (Φ2) β-cell responsiveness indexes provided by C-peptide minimal model. Validation of the surrogate insulin sensitivity index (ISI) and of two sets of coupled insulin-based indexes for insulin secretion, differing from the cut-off point between phases (FPIR3-SPIR3, t = 3 min and FPIR5-SPIR5, t = 5 min), was carried out in a population of ten Zucker fatty rats (ZFR) and ten Zucker lean rats (ZLR). Considering the whole rat population (ZLR+ZFR), ISI showed a significant strong correlation with SI (Spearman's correlation coefficient, r = 0.88; P<0.001). Both FPIR3 and FPIR5 showed a significant (P<0.001) strong correlation with Φ1 (r = 0.76 and r = 0.75, respectively). Both SPIR3 and SPIR5 showed a significant (P<0.001) strong correlation with Φ2 (r = 0.85 and r = 0.83, respectively). ISI is able to detect (P<0.001) the well-recognized reduction in insulin sensitivity in ZFRs, compared to ZLRs. The insulin-based indexes of insulin secretion are able to detect in ZFRs (P<0.001) the compensatory increase of first- and second-phase secretion, associated to the insulin-resistant state. The ability of the surrogate indexes in describing glucose tolerance in the ZFRs was confirmed by the Disposition Index analysis. The model-based validation performed in the present study supports the utilization of low-cost, insulin-based indexes for the assessment of glucose tolerance in Zucker rat, reliable animal model of human metabolic syndrome.

  18. A comparison of five approaches to measurement of anatomic knee alignment from radiographs.

    PubMed

    McDaniel, G; Mitchell, K L; Charles, C; Kraus, V B

    2010-02-01

    The recent recognition of the correlation of the hip-knee-ankle angle (HKA) with femur-tibia angle (FTA) on a standard knee radiograph has led to the increasing inclusion of FTA assessments in OA studies due to its clinical relevance, cost effectiveness and minimal radiation exposure. Our goal was to investigate the performance metrics of currently used methods of FTA measurement to determine whether a specific protocol could be recommended based on these results. Inter- and intra-rater reliability of FTA measurements were determined by intraclass correlation coefficient (ICC) of two independent analysts. Minimal detectable differences were determined and the correlation of FTA and HKA was analyzed by linear regression. Differences among methods of measuring HKA were assessed by ANOVA. All five methods of FTA measurement demonstrated high precision by inter- and intra-rater reproducibility (ICCs>or=0.93). All five methods displayed good accuracy, but after correction for the offset of FTA from HKA, the femoral notch landmark method was the least accurate. However, the methods differed according to their minimal detectable differences; the FTA methods utilizing the center of the base of the tibial spines or the center of the tibial plateau as knee center landmarks yielded the smallest minimal detectable differences (1.25 degrees and 1.72 degrees, respectively). All methods of FTA were highly reproducible, but varied in their accuracy and sensitivity to detect meaningful differences. Based on these parameters we recommend standardizing measurement angles with vertices at the base of the tibial spines or the center of the tibia and comparing single-point and two-point methods in larger studies. Copyright 2009 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.

  19. Spiral-Bevel-Gear Damage Detected Using Decision Fusion Analysis

    NASA Technical Reports Server (NTRS)

    Dempsey, Paula J.; Handschuh, Robert F.

    2003-01-01

    Helicopter transmission integrity is critical to helicopter safety because helicopters depend on the power train for propulsion, lift, and flight maneuvering. To detect impending transmission failures, the ideal diagnostic tools used in the health-monitoring system would provide real-time health monitoring of the transmission, demonstrate a high level of reliable detection to minimize false alarms, and provide end users with clear information on the health of the system without requiring them to interpret large amounts of sensor data. A diagnostic tool for detecting damage to spiral bevel gears was developed. (Spiral bevel gears are used in helicopter transmissions to transfer power between nonparallel intersecting shafts.) Data fusion was used to integrate two different monitoring technologies, oil debris analysis and vibration, into a health-monitoring system for detecting surface fatigue pitting damage on the gears.

  20. Detection Copy Number Variants from NGS with Sparse and Smooth Constraints.

    PubMed

    Zhang, Yue; Cheung, Yiu-Ming; Xu, Bo; Su, Weifeng

    2017-01-01

    It is known that copy number variations (CNVs) are associated with complex diseases and particular tumor types, thus reliable identification of CNVs is of great potential value. Recent advances in next generation sequencing (NGS) data analysis have helped manifest the richness of CNV information. However, the performances of these methods are not consistent. Reliably finding CNVs in NGS data in an efficient way remains a challenging topic, worthy of further investigation. Accordingly, we tackle the problem by formulating CNVs identification into a quadratic optimization problem involving two constraints. By imposing the constraints of sparsity and smoothness, the reconstructed read depth signal from NGS is anticipated to fit the CNVs patterns more accurately. An efficient numerical solution tailored from alternating direction minimization (ADM) framework is elaborated. We demonstrate the advantages of the proposed method, namely ADM-CNV, by comparing it with six popular CNV detection methods using synthetic, simulated, and empirical sequencing data. It is shown that the proposed approach can successfully reconstruct CNV patterns from raw data, and achieve superior or comparable performance in detection of the CNVs compared to the existing counterparts.

  1. TEST-RETEST RELIABILITY OF THE CLOSED KINETIC CHAIN UPPER EXTREMITY STABILITY TEST (CKCUEST) IN ADOLESCENTS: RELIABILITY OF CKCUEST IN ADOLESCENTS.

    PubMed

    de Oliveira, Valéria M A; Pitangui, Ana C R; Nascimento, Vinícius Y S; da Silva, Hítalo A; Dos Passos, Muana H P; de Araújo, Rodrigo C

    2017-02-01

    The Closed Kinetic Chain Upper Extremity Stability Test (CKCUEST) has been proposed as an option to assess upper limb function and stability; however, there are few studies that support the use of this test in adolescents. The purpose of the present study was to investigate the intersession reliability and agreement of three CKCUEST scores in adolescents and establish clinimetric values for this test. Test-retest reliability. Twenty-five healthy adolescents of both sexes were evaluated. The subjects performed two CKCUEST with an interval of one week between the tests. An intraclass correlation coefficient (ICC 3,3 ) two-way mixed model with a 95% interval of confidence was utilized to determine intersession reliability. A Bland-Altman graph was plotted to analyze the agreement between assessments. The presence of systematic error was evaluated by a one-sample t test. The difference between the evaluation and reevaluation was observed using a paired-sample t test. The level of significance was set at 0.05. Standard error of measurements and minimum detectable changes were calculated. The intersession reliability of the average touches score, normalized score, and power score were 0.68, 0.68 and 0.87, the standard error of measurement were 2.17, 1.35 and 6.49, and the minimal detectable change was 6.01, 3.74 and 17.98, respectively. The presence of systematic error (p < 0.014), the significant difference between the measurements (p < 0.05), and the analysis of the Bland-Altman graph infer that CKCUEST is a discordant test with moderate to excellent reliability when used with adolescents. The CKCUEST is a measurement with moderate to excellent reliability for adolescents. 2b.

  2. Detection of single bacteria - causative agents of meningitis using raman microscopy

    NASA Astrophysics Data System (ADS)

    Baikova, T. V.; Minaeva, S. A.; Sundukov, A. V.; Svistunova, T. S.; Bagratashvili, V. N.; Alushin, M. V.; Gonchukov, S. A.

    2015-03-01

    Early diagnostics of meningitis is a very topical problem as it is a fulminant disease with a high level of mortality. The progress of this disease is, as a rule, accompanied by the appearance of bacteria in the cerebrospinal fluid (CSF) composition. The examination of the CSF is well known to be the only reliable approach to the identification of meningitis. However, the traditional biochemical analyses are time consuming and not always reliable, simple, and inexpensive, whereas the optical methods are poorly developed. This work is devoted to the study of Raman spectra of several bacterial cultures which are mainly present during meningitis. Raman microscopy is a prompt and noninvasive technique capable of providing reliable information about molecular-level alterations of biological objects at their minimal quantity and size. It was shown that there are characteristic lines in Raman spectra which can be the reliable markers for determination of bacterial form of meningitis at a level of a single bacterium.

  3. Validation of missed space-group symmetry in X-ray powder diffraction structures with dispersion-corrected density functional theory.

    PubMed

    Hempler, Daniela; Schmidt, Martin U; van de Streek, Jacco

    2017-08-01

    More than 600 molecular crystal structures with correct, incorrect and uncertain space-group symmetry were energy-minimized with dispersion-corrected density functional theory (DFT-D, PBE-D3). For the purpose of determining the correct space-group symmetry the required tolerance on the atomic coordinates of all non-H atoms is established to be 0.2 Å. For 98.5% of 200 molecular crystal structures published with missed symmetry, the correct space group is identified; there are no false positives. Very small, very symmetrical molecules can end up in artificially high space groups upon energy minimization, although this is easily detected through visual inspection. If the space group of a crystal structure determined from powder diffraction data is ambiguous, energy minimization with DFT-D provides a fast and reliable method to select the correct space group.

  4. Development and Reliability Testing of the Comprehensive High-Level Activity Mobility Predictor (CHAMP) in Male Servicemembers with Traumatic Lower-Limb Loss

    DTIC Science & Technology

    2013-01-01

    Levin GT, Ben Abdelkrim N, Laurencelle L, Castagna C. Lower limb maxi- mal dynamic strength and agility determinants in elite basket - ball players . J...IRB = Institutional Review Board, LLL = lower-limb loss, MBP = Medicine Ball Put, MDC = minimal detectable change, NMCSD = Naval Medical Center...consid- ered for the CHAMP. Coordination, power, speed, and agility are important physical components necessary for successful perfor- mance in sports

  5. Highly sensitive MYD88L265P mutation detection by droplet digital PCR in Waldenström Macroglobulinemia.

    PubMed

    Drandi, Daniela; Genuardi, Elisa; Dogliotti, Irene; Ferrante, Martina; Jiménez, Cristina; Guerrini, Francesca; Lo Schirico, Mariella; Mantoan, Barbara; Muccio, Vittorio; Lia, Giuseppe; Zaccaria, Gian Maria; Omedè, Paola; Passera, Roberto; Orsucci, Lorella; Benevolo, Giulia; Cavallo, Federica; Galimberti, Sara; García-Sanz, Ramón; Boccadoro, Mario; Ladetto, Marco; Ferrero, Simone

    2018-03-22

    We here describe a novel method for MYD88 L265P mutation detection and minimal residual disease monitoring in Waldenström Macroglobulinemia, by droplet digital PCR, in bone marrow and peripheral blood cells, as well as in circulating cell free DNA. Our method shows a sensitivity of 5.00E-05, by far superior to the widely used allele-specific polymerase chain reaction (1.00E-03). Overall, 291 unsorted samples from 148 patients (133 Waldenstrom 11 IgG-lymphoplasmacytic lymphoma and 4 IgM-monoclonal gammopathy of undetermined significance), 194 baseline and 97 follow-up, were analyzed. 122/128 (95.3%) bone marrow and 47/66 (71.2%) baseline peripheral blood samples scored positive for MYD88 L265P Moreover, to investigate whether MYD88 L265P by droplet digital PCR could be used for minimal residual disease monitoring, mutation levels were compared with IGH-based minimal residual disease analysis in 10 patients, showing to be as informative as to the classical, standardized but not yet validated in Waldenström Macroglobulinemia, IGH-based minimal residual disease assay (r 2 =0.64). Finally, MYD88 L265P detection performed by droplet digital PCR on plasmatic circulating tumor DNA from 60 patients showed a good correlation with bone marrow (bone marrow median mutational value 1.92E-02, plasmatic circulating tumor DNA value: 1.4E-02, peripheral blood value: 1.03E-03). This study indicates that droplet digital PCR MYD88 L265P assay is a feasible and sensitive tool for mutational screening and minimal residual disease monitoring in Waldenström Macroglobulinemia. Both unsorted bone marrow and peripheral blood samples can be reliably tested, as well as circulating tumor DNA, that represents an attractive, less invasive alternative to bone marrow for MYD88 L265P detection. Copyright © 2018, Ferrata Storti Foundation.

  6. Light scattering techniques for the characterization of optical components

    NASA Astrophysics Data System (ADS)

    Hauptvogel, M.; Schröder, S.; Herffurth, T.; Trost, M.; von Finck, A.; Duparré, A.; Weigel, T.

    2017-11-01

    The rapid developments in optical technologies generate increasingly higher and sometimes completely new demands on the quality of materials, surfaces, components, and systems. Examples for such driving applications are the steadily shrinking feature sizes in semiconductor lithography, nanostructured functional surfaces for consumer optics, and advanced optical systems for astronomy and space applications. The reduction of surface defects as well as the minimization of roughness and other scatter-relevant irregularities are essential factors in all these areas of application. Quality-monitoring for analysing and improving those properties must ensure that even minimal defects and roughness values can be detected reliably. Light scattering methods have a high potential for a non-contact, rapid, efficient, and sensitive determination of roughness, surface structures, and defects.

  7. Psychometric viability of measures of functional performance commonly used for people with dementia: a systematic review of measurement properties.

    PubMed

    Fox, Benjamin; Henwood, Timothy; Keogh, Justin; Neville, Christine

    2016-08-01

    Confidence in findings can only be drawn from measurement tools that have sound psychometric properties for the population with which they are used. Within a dementia specific population, measures of physical function have been poorly justified in exercise intervention studies, with justification of measures based on validity or reliability studies from dissimilar clinical populations, such as people with bronchitis or healthy older adults without dementia. To review the reliability and validity of quantitative measures of pre-identified physical function, as commonly used within exercise intervention literature for adults with dementia. Participants were adults, aged 65 years and older, with a confirmed medical diagnosis of dementia. n/a Desired studies were observational and cross-sectional and that assessed measures from a pre-identified list of measures of physical function. Studies that assessed the psychometric constructs of reliability and validity were targeted. COSMIN taxology was used to define reliability and validity. This included, but were not limited to, Intra-Class Correlations, Kappa, Cronbach's Alpha, Chi Squared, Standard Error of Measurement, Minimal Detectable Change and Limits of Agreement. Published material was sourced from the following four databases: MEDLINE, EMBASE, CINAHL and ISI Web of Science. Grey literature was searched for using ALOIS, Google Scholar and ProQuest. The COSMIN checklist was used to assess methodological quality of included studies. Assessment was completed by two reviewers independently. Reliability and validity data was extracted from included studies using standardized Joanna Briggs Institute data collection forms. Extraction was completed by two reviewers. A narrative synthesis of measurement properties of the tools used to measure physical function was performed. Quantitative meta-analysis was conducted for Intra-Class Correlation Coefficients only. With respect to relative reliability, studies reporting assessed measures had intraclass correlation coefficients greater than 0.71, indicating their suitability for use at a group level. However, a consistent finding among studies that included assessment of absolute reliability was that intra individual variation was too large for meaningful measurement of individuals. This was indicated by large Minimal Detectable Change (MDC) scores. Walk Speed has the smallest reported Mimimal Detectable Change score at 0.11m/s. This represented a change of 35% before statistical variation could be eliminated as the cause for this change. All measures had large MDC values. Walk Speed had the smallest MDC values at 0.11m/s, which represented a necessary change of 35%. Only a limited number of studies assessed the validity of measures. This supports the use of these measures in a very narrow selection of circumstances (see Summary of Findings). In summary, measures have shown appropriate levels of relative reliability. This supports their use at the group level. However, large levels of intra-individual variation undermine their applicability at the individual level. Limited studies of validity were available to this review, which limits a conclusion on whether measures are valid for people with dementia.

  8. A Review on Microfluidic Paper-Based Analytical Devices for Glucose Detection

    PubMed Central

    Liu, Shuopeng; Su, Wenqiong; Ding, Xianting

    2016-01-01

    Glucose, as an essential substance directly involved in metabolic processes, is closely related to the occurrence of various diseases such as glucose metabolism disorders and islet cell carcinoma. Therefore, it is crucial to develop sensitive, accurate, rapid, and cost effective methods for frequent and convenient detections of glucose. Microfluidic Paper-based Analytical Devices (μPADs) not only satisfying the above requirements but also occupying the advantages of portability and minimal sample consumption, have exhibited great potential in the field of glucose detection. This article reviews and summarizes the most recent improvements in glucose detection in two aspects of colorimetric and electrochemical μPADs. The progressive techniques for fabricating channels on μPADs are also emphasized in this article. With the growth of diabetes and other glucose indication diseases in the underdeveloped and developing countries, low-cost and reliably commercial μPADs for glucose detection will be in unprecedentedly demand. PMID:27941634

  9. Aliphatic long chain quaternary ammonium compounds analysis by ion-pair chromatography coupled with suppressed conductivity and UV detection in lysing reagents for blood cell analysers.

    PubMed

    Giovannelli, D; Abballe, F

    2005-08-26

    A method has been developed which allows simultaneous determination of three linear alkyl trimethylammonium salts. Dodecyltrimethylammonium chloride, tetradecyltrimethylammonium bromide and hexadecyltrimethylammonium chloride are widely used as main active ingredients of lysing reagents for blood cell analyzers which perform white blood cells differential determination into two or more sub-populations by impedance analysis. The ion-pair on styrene-divinyl benzene chromatographic phase looks like a suitable, reliable and long term stable tool for separation of such quaternary compounds. The detection based on suppressed conductivity was chosen because of the lack of significance chromophores. A micromembrane suppressor device compatible with high solvent concentration (up to 80%) was used in order to minimize the conductivity background before the detection. In the present work we show how the chemical post column derivatization makes the alkyl chain detectable also by UV direct detection at 210 nm.

  10. Method for phosphorothioate antisense DNA sequencing by capillary electrophoresis with UV detection.

    PubMed

    Froim, D; Hopkins, C E; Belenky, A; Cohen, A S

    1997-11-01

    The progress of antisense DNA therapy demands development of reliable and convenient methods for sequencing short single-stranded oligonucleotides. A method of phosphorothioate antisense DNA sequencing analysis using UV detection coupled to capillary electrophoresis (CE) has been developed based on a modified chain termination sequencing method. The proposed method reduces the sequencing cost since it uses affordable CE-UV instrumentation and requires no labeling with minimal sample processing before analysis. Cycle sequencing with ThermoSequenase generates quantities of sequencing products that are readily detectable by UV. Discrimination of undesired components from sequencing products in the reaction mixture, previously accomplished by fluorescent or radioactive labeling, is now achieved by bringing concentrations of undesired components below the UV detection range which yields a 'clean', well defined sequence. UV detection coupled with CE offers additional conveniences for sequencing since it can be accomplished with commercially available CE-UV equipment and is readily amenable to automation.

  11. Method for phosphorothioate antisense DNA sequencing by capillary electrophoresis with UV detection.

    PubMed Central

    Froim, D; Hopkins, C E; Belenky, A; Cohen, A S

    1997-01-01

    The progress of antisense DNA therapy demands development of reliable and convenient methods for sequencing short single-stranded oligonucleotides. A method of phosphorothioate antisense DNA sequencing analysis using UV detection coupled to capillary electrophoresis (CE) has been developed based on a modified chain termination sequencing method. The proposed method reduces the sequencing cost since it uses affordable CE-UV instrumentation and requires no labeling with minimal sample processing before analysis. Cycle sequencing with ThermoSequenase generates quantities of sequencing products that are readily detectable by UV. Discrimination of undesired components from sequencing products in the reaction mixture, previously accomplished by fluorescent or radioactive labeling, is now achieved by bringing concentrations of undesired components below the UV detection range which yields a 'clean', well defined sequence. UV detection coupled with CE offers additional conveniences for sequencing since it can be accomplished with commercially available CE-UV equipment and is readily amenable to automation. PMID:9336449

  12. Reliability, validity and minimal detectable change of the Mini-BESTest in Greek participants with chronic stroke.

    PubMed

    Lampropoulou, Sofia I; Billis, Evdokia; Gedikoglou, Ingrid A; Michailidou, Christina; Nowicky, Alexander V; Skrinou, Dimitra; Michailidi, Fotini; Chandrinou, Danae; Meligkoni, Margarita

    2018-02-23

    This study aimed to investigate the psychometric characteristics of reliability, validity and ability to detect change of a newly developed balance assessment tool, the Mini-BESTest, in Greek patients with stroke. A prospective, observational design study with test-retest measures was conducted. A convenience sample of 21 Greek patients with chronic stroke (14 male, 7 female; age of 63 ± 16 years) was recruited. Two independent examiners administered the scale, for the inter-rater reliability, twice within 10 days for the test-retest reliability. Bland Altman Analysis for repeated measures assessed the absolute reliability and the Standard Error of Measurement (SEM) and the Minimum Detectable Change at 95% confidence interval (MDC 95% ) were established. The Greek Mini-BESTest (Mini-BESTest GR ) was correlated with the Greek Berg Balance Scale (BBS GR ) for assessing the concurrent validity and with the Timed Up and Go (TUG), the Functional Reach Test (FRT) and the Greek Falls Efficacy Scale-International (FES-I GR ) for the convergent validity. The Mini-BESTestGR demonstrated excellent inter-rater reliability (ICC (95%CI) = 0.997 (0.995-0.999, SEM = 0.46) with the scores of two raters within the limits of agreement (mean dif  = -0.143 ± 0.727, p > 0.05) and test-retest reliability (ICC (95%CI) = 0.966 (0.926-0.988), SEM = 1.53). Additionally, the Mini-BESTest GR yielded very strong to moderate correlations with BBS GR (r = 0.924, p < 0.001), TUG (r = -0.823, p < 0.001), FES-I GR (r = -0.734, p < 0.001) and FRT (r = 0.689, p < 0.001). MDC 95 was 4.25 points. The exceptionally high reliability and the equally good validity of the Mini-BESTest GR , strongly support its utility in Greek people with chronic stroke. Its ability to identify clinically meaningful changes and falls risk need further investigation.

  13. Comparison of reliability and responsiveness of patient-reported clinical outcome measures in knee osteoarthritis rehabilitation.

    PubMed

    Williams, Valerie J; Piva, Sara R; Irrgang, James J; Crossley, Chad; Fitzgerald, G Kelley

    2012-08-01

    Secondary analysis, pretreatment-posttreatment observational study. To compare the reliability and responsiveness of the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), the Knee Outcome Survey activities of daily living subscale (KOS-ADL), and the Lower Extremity Functional Scale (LEFS) in individuals with knee osteoarthritis (OA). The WOMAC is the current standard in patient-reported measures of function in patients with knee OA. The KOS-ADL and LEFS were designed for potential use in patients with knee OA. If the KOS-ADL and LEFS are to be considered viable alternatives to the WOMAC for measuring patient-reported function in individuals with knee OA, they should have measurement properties comparable to the WOMAC. It would also be important to determine whether either of these instruments may be superior to the WOMAC in terms of reliability or responsiveness in this population. Data from 168 subjects with knee OA, who participated in a rehabilitation program, were used in the analyses. Reliability and responsiveness of each outcome measure were estimated at follow-ups of 2, 6, and 12 months. Reliability was estimated by calculating the intraclass correlation coefficient (ICC2,1) for subjects who were unchanged in status from baseline at each follow-up time, based on a global rating of change score. To examine responsiveness, the standard error of the measurement, minimal detectable change, minimal clinically important difference, and the Guyatt responsiveness index were calculated for each outcome measure at each follow-up time. All 3 outcome measures demonstrated reasonable reliability and responsiveness to change. Reliability and responsiveness tended to decrease somewhat with increasing follow-up time. There were no substantial differences between outcome measures for reliability or any of the 3 measures of responsiveness at any follow-up time. The results do not indicate that one outcome measure is more reliable or responsive than another when applied to subjects with knee OA. We believe that all 3 instruments are appropriate outcome measures to examine change in functional status of patients with knee OA.

  14. Sensitive sub-Doppler nonlinear spectroscopy for hyperfine-structure analysis using simple atomizers

    NASA Astrophysics Data System (ADS)

    Mickadeit, Fritz K.; Kemp, Helen; Schafer, Julia; Tong, William M.

    1998-05-01

    Laser wave-mixing spectroscopy is presented as a sub-Doppler method that offers not only high spectral resolution, but also excellent detection sensitivity. It offers spectral resolution suitable for hyperfine structure analysis and isotope ratio measurements. In a non-planar backward- scattering four-wave mixing optical configuration, two of the three input beams counter propagate and the Doppler broadening is minimized, and hence, spectral resolution is enhanced. Since the signal is a coherent beam, optical collection is efficient and signal detection is convenient. This simple multi-photon nonlinear laser method offers un usually sensitive detection limits that are suitable for trace-concentration isotope analysis using a few different types of simple analytical atomizers. Reliable measurement of hyperfine structures allows effective determination of isotope ratios for chemical analysis.

  15. Development of the Modified Four Square Step Test and its reliability and validity in people with stroke.

    PubMed

    Roos, Margaret A; Reisman, Darcy S; Hicks, Gregory; Rose, William; Rudolph, Katherine S

    2016-01-01

    Adults with stroke have difficulty avoiding obstacles when walking, especially when a time constraint is imposed. The Four Square Step Test (FSST) evaluates dynamic balance by requiring individuals to step over canes in multiple directions while being timed, but many people with stroke are unable to complete it. The purposes of this study were to (1) modify the FSST by replacing the canes with tape so that more persons with stroke could successfully complete the test and (2) examine the reliability and validity of the modified version. Fifty-five subjects completed the Modified FSST (mFSST) by stepping over tape in all four directions while being timed. The mFSST resulted in significantly greater numbers of subjects completing the test than the FSST (39/55 [71%] and 33/55 [60%], respectively) (p < 0.04). The test-retest, intrarater, and interrater reliability of the mFSST were excellent (intraclass correlation coefficient ranges: 0.81-0.99). Construct and concurrent validity of the mFSST were also established. The minimal detectable change was 6.73 s. The mFSST, an ideal measure of dynamic balance, can identify progress in people with stroke in varied settings and can be completed by a wide range of people with stroke in approximately 5 min with the use of minimal equipment (tape, stop watch).

  16. The development and validation of a questionnaire for rotator cuff disorders: The Functional Shoulder Score

    PubMed Central

    Ibrahim, Edward F; Petrou, Charalambos; Galanos, Antonis

    2015-01-01

    Background The purpose of the present study was to validate the Functional Shoulder Score (FSS), a new patient-reported outcome score specifically designed to evaluate patients with rotator cuff disorders. Methods One hundred and nineteen patients were assessed using two shoulder scoring systems [the FSS and the Constant–Murley Score (CMS)] at 3 weeks pre- and 6 months post-arthroscopic rotator cuff surgery. The reliability, validity, responsiveness and interpretability of the FSS were evaluated. Results Reliability analysis (test–retest) showed an intraclass correlation coefficient value of 0.96 [95% confidence interval (CI) = 0.92 to 0.98]. Internal consistency analysis revealed a Cronbach's alpha coefficient of 0.93. The Pearson correlation coefficient FSS-CMS was 0.782 pre-operatively and 0.737 postoperatively (p < 0.0005). There was a statistically significant increase in FSS scores postoperatively, an effect size of 3.06 and standardized response mean of 2.80. The value for minimal detectable change was ±8.38 scale points (based on a 90% CI) and the minimal clinically important difference for improvement was 24.7 ± 5.4 points. Conclusions The FSS is a patient-reported outcome measure that can easily be incorporated into clinical practice, providing a quick, reliable, valid and practical measure for rotator cuff problems. The questionnaire is highly sensitive to clinical change. PMID:27582986

  17. Fast and efficient molecule detection in localization-based super-resolution microscopy by parallel adaptive histogram equalization.

    PubMed

    Li, Yiming; Ishitsuka, Yuji; Hedde, Per Niklas; Nienhaus, G Ulrich

    2013-06-25

    In localization-based super-resolution microscopy, individual fluorescent markers are stochastically photoactivated and subsequently localized within a series of camera frames, yielding a final image with a resolution far beyond the diffraction limit. Yet, before localization can be performed, the subregions within the frames where the individual molecules are present have to be identified-oftentimes in the presence of high background. In this work, we address the importance of reliable molecule identification for the quality of the final reconstructed super-resolution image. We present a fast and robust algorithm (a-livePALM) that vastly improves the molecule detection efficiency while minimizing false assignments that can lead to image artifacts.

  18. Optical spectroscopy for quantitative sensing in human pancreatic tissues

    NASA Astrophysics Data System (ADS)

    Wilson, Robert H.; Chandra, Malavika; Lloyd, William; Chen, Leng-Chun; Scheiman, James; Simeone, Diane; McKenna, Barbara; Mycek, Mary-Ann

    2011-07-01

    Pancreatic adenocarcinoma has a five-year survival rate of only 6%, largely because current diagnostic methods cannot reliably detect the disease in its early stages. Reflectance and fluorescence spectroscopies have the potential to provide quantitative, minimally-invasive means of distinguishing pancreatic adenocarcinoma from normal pancreatic tissue and chronic pancreatitis. The first collection of wavelength-resolved reflectance and fluorescence spectra and time-resolved fluorescence decay curves from human pancreatic tissues was acquired with clinically-compatible instrumentation. Mathematical models of reflectance and fluorescence extracted parameters related to tissue morphology and biochemistry that were statistically significant for distinguishing between pancreatic tissue types. These results suggest that optical spectroscopy has the potential to detect pancreatic disease in a clinical setting.

  19. FPGA-Based X-Ray Detection and Measurement for an X-Ray Polarimeter

    NASA Technical Reports Server (NTRS)

    Gregory, Kyle; Hill, Joanne; Black, Kevin; Baumgartner, Wayne

    2013-01-01

    This technology enables detection and measurement of x-rays in an x-ray polarimeter using a field-programmable gate array (FPGA). The technology was developed for the Gravitational and Extreme Magnetism Small Explorer (GEMS) mission. It performs precision energy and timing measurements, as well as rejection of non-x-ray events. It enables the GEMS polarimeter to detect precisely when an event has taken place so that additional measurements can be made. The technology also enables this function to be performed in an FPGA using limited resources so that mass and power can be minimized while reliability for a space application is maximized and precise real-time operation is achieved. This design requires a low-noise, charge-sensitive preamplifier; a highspeed analog to digital converter (ADC); and an x-ray detector with a cathode terminal. It functions by computing a sum of differences for time-samples whose difference exceeds a programmable threshold. A state machine advances through states as a programmable number of consecutive samples exceeds or fails to exceed this threshold. The pulse height is recorded as the accumulated sum. The track length is also measured based on the time from the start to the end of accumulation. For track lengths longer than a certain length, the algorithm estimates the barycenter of charge deposit by comparing the accumulator value at the midpoint to the final accumulator value. The design also employs a number of techniques for rejecting background events. This innovation enables the function to be performed in space where it can operate autonomously with a rapid response time. This implementation combines advantages of computing system-based approaches with those of pure analog approaches. The result is an implementation that is highly reliable, performs in real-time, rejects background events, and consumes minimal power.

  20. Test-retest reliability and responsiveness of gaze stability and dynamic visual acuity in high school and college football players.

    PubMed

    Kaufman, Denise R; Puckett, Mallory J; Smith, Mitchell J; Wilson, Kyle S; Cheema, Rebecca; Landers, Merrill R

    2014-08-01

    The purpose of this study was to establish reliability and responsiveness of the dynamic visual acuity test (DVAT) at head speeds of 150-200 degrees per second (deg/s) and the gaze stabilization test (GST) in high school and college football players. Reliability design. Fifty high school and college football athletes completed the DVAT and GST in both the yaw (horizontal) and pitch (vertical) planes twice within two weeks. Test-retest reliability for the DVAT was good in yaw, Intraclass Correlation Coefficient (ICC) = 0.770, and moderate/good in pitch, ICC = 0.725. Minimal detectable change (MDC) was 0.16 logMAR for yaw and 0.21 logMAR for pitch. GST reliability was moderate in yaw, ICC = 0.634, and poor in pitch, ICC = 0.411. MDCs were 73.4 deg/s (yaw) and 81.2 deg/s (pitch). The DVAT is reliable at high head speeds in high school and college football athletes in both yaw and pitch. GST head speeds were higher than previously reported in the literature, but reliability of this tool for this population was poor to moderate. From a clinical perspective, DVAT may be reliably used in the assessment of high school and college football athletes; however, GST requires further evaluation. Copyright © 2013 Elsevier Ltd. All rights reserved.

  1. Reliability of the Berg Balance Scale as a Clinical Measure of Balance in Community-Dwelling Older Adults with Mild to Moderate Alzheimer Disease: A Pilot Study.

    PubMed

    Muir-Hunter, Susan W; Graham, Laura; Montero Odasso, Manuel

    2015-08-01

    To measure test-retest and interrater reliability of the Berg Balance Scale (BBS) in community-dwelling adults with mild to moderate Alzheimer disease (AD). Method : A sample of 15 adults (mean age 80.20 [SD 5.03] years) with AD performed three balance tests: the BBS, timed up-and-go test (TUG), and Functional Reach Test (FRT). Both relative reliability, using the intra-class correlation coefficient (ICC), and absolute reliability, using standard error of measurement (SEM) and minimal detectable change (MDC95) values, were calculated; Bland-Altman plots were constructed to evaluate inter-tester agreement. The test-retest interval was 1 week. Results : For the BBS, relative reliability values were 0.95 (95% CI, 0.85-0.98) for test-retest reliability and 0.72 (95% CI, 0.31-0.91) for interrater reliability; SEM was 6.01 points and MDC95 was 16.66 points; and interrater agreement was 16.62 points. The BBS performed better in test-retest reliability than the TUG and FRT, tests with established reliability in AD. Between 33% and 50% of participants required cueing beyond standardized instructions because they were unable to remember test instructions. Conclusions : The BBS achieved relative reliability values that support its clinical utility, but MDC95 and agreement values indicate the scale has performance limitations in AD. Further research to optimize balance assessment for people with AD is required.

  2. Surveillance for unattended gas compressor stations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stastny, F.J.

    1974-06-01

    Surveillance devices in unattended compressor stations include those which detect trespassing by unauthorized personnel and those which protect the major operating equipment from damage and/or self-destruction. The latter monitor the critical operating parameters of major equipment and shut down the equipment when these parameters are exceeded; a table presents a function monitor and control list for such devices. Detection and apprehension of unauthorized personnel is a subject of increasing importance to guarantee station operability for reliable service and yet minimize staff personnel. An effective intrusion-detection system must (1) pinpoint the location and indicate the nature of the intrusion and (2)more » detect and respond rapidly to give security personnel a reasonable probability of apprehending or deterring the intruder before damage is done. The 2nd requirement is most difficult to satisfy when the facility is in a remote location, as is usually the case. Some of the parameters to consider in selecting an intrusion-detection system include concealment, legality, active vs. passive detector, back-up power, weather conditions, reliability, maintenance, discrimination, and compromising by intruders. Types of detectors include photo cell, infrared and radio frequency, audio,vibration, taut wire, circuit continuity, radar, and closed-circuit TV. The numerous types of devices and systems available provide sufficient diversity to enable a company to select a single device or a hybrid system which would incorporate several different devices for protecting unattended facilities.« less

  3. Reliability and Responsiveness of NutriQoL® Questionnaire.

    PubMed

    Cuerda, Maria Cristina; Apezetxea, Antonio; Carrillo, Lourdes; Casanueva, Felipe; Cuesta, Federico; Irles, Jose Antonio; Virgili, Maria Nuria; Layola, Miquel; Lizán, Luis

    2016-10-01

    NutriQoL ® (Nestlé Health Science, Vevay, Switzerland) is a questionnaire developed to assess the health-related quality-of-life (HRQoL) of patients with home enteral nutrition (HEN) irrespective of their underlying condition and route of administration. The aim of this work is assessing the questionnaire's reliability and responsiveness to change. Two cohorts of patients with HEN and their primary caregivers were enrolled to assess reliability and responsiveness, respectively. All participants had to be 18 years of age or older, without mental deterioration (≤3 or 4 errors in the Pfeiffer's test) and with sufficient functional status (>40 points on Karnovsky's performance status scale). When the patients' ability to respond to the questionnaire was impaired due to underlying disease, their caregivers answered on their behalf. NutriQoL was administered in two and three visits to reliability and responsiveness cohorts, respectively. Test-retest reliability and internal consistency were assessed by the intra-class correlation coefficient (ICC) and the Cronbach's α, respectively. Responsiveness was evaluated by standardized effect size and standardized response mean between basal visit and third visit. Finally, the minimal clinically important difference (MCID) was estimated. A total of 54 and 86 participants were recruited to the reliability and responsiveness cohort, respectively. Thirty-five caregivers were selected to assess the inter-observer reliability. ICC values confirmed the good reproducibility level (ICC >0.75) of the questionnaire in both "physical functioning and activities of daily living" and "social life" domains and total score. The assessment of internal consistency in both domains of the questionnaire showed good internal consistency in visit 2. ICC showed the excellent agreement level between caregiver and patient in the global NutriQoL score. Finally, patients classified as having a minimal change in their health reported a mean (standard deviation) MCID in NutriQoL score of 0.63 (11.51). NutriQoL is a reliable and unique instrument to measure the HRQoL in HEN patients. NutriQoL detects changes in the health status of the patient. Nevertheless, further research is needed to determine the full extent of the questionnaire responsiveness.

  4. Circulating tumor DNA as a liquid biopsy target for detection of pancreatic cancer

    PubMed Central

    Takai, Erina; Yachida, Shinichi

    2016-01-01

    Most pancreatic cancer patients present with advanced metastatic disease, resulting in extremely poor 5-year survival, mainly because of the lack of a reliable modality for early detection and limited therapeutic options for advanced disease. Therefore, there is a need for minimally-invasive diagnostic tools for detecting pancreatic cancer at an early stage, when curative surgery and also novel therapeutic approaches including precision medicine may be feasible. The “liquid biopsy” addresses these unmet clinical needs based on the concept that simple peripheral blood sampling and detection of circulating tumor DNA (ctDNA) could provide diagnostic information. In this review, we provide an overview of the current status of blood-based tests for diagnosis of pancreatic cancer and the potential utility of ctDNA for precision medicine. We also discuss challenges that remain to be addressed in developing practical ctDNA-based liquid biopsy approaches for early diagnosis of pancreatic cancer. PMID:27784960

  5. Circulating tumor DNA as a liquid biopsy target for detection of pancreatic cancer.

    PubMed

    Takai, Erina; Yachida, Shinichi

    2016-10-14

    Most pancreatic cancer patients present with advanced metastatic disease, resulting in extremely poor 5-year survival, mainly because of the lack of a reliable modality for early detection and limited therapeutic options for advanced disease. Therefore, there is a need for minimally-invasive diagnostic tools for detecting pancreatic cancer at an early stage, when curative surgery and also novel therapeutic approaches including precision medicine may be feasible. The "liquid biopsy" addresses these unmet clinical needs based on the concept that simple peripheral blood sampling and detection of circulating tumor DNA (ctDNA) could provide diagnostic information. In this review, we provide an overview of the current status of blood-based tests for diagnosis of pancreatic cancer and the potential utility of ctDNA for precision medicine. We also discuss challenges that remain to be addressed in developing practical ctDNA-based liquid biopsy approaches for early diagnosis of pancreatic cancer.

  6. Inferring Gear Damage from Oil-Debris and Vibration Data

    NASA Technical Reports Server (NTRS)

    Dempsey, Paula

    2006-01-01

    A system for real-time detection of surface-fatigue-pitting damage to gears for use in a helicopter transmission is based on fuzzy-logic used to fuse data from sensors that measure oil-borne debris, referred to as "oil debris" in the article, and vibration signatures. A system to detect helicopter-transmission gear damage is beneficial because the power train of a helicopter is essential for propulsion, lift, and maneuvering, hence, the integrity of the transmission is critical to helicopter safety. To enable detection of an impending transmission failure, an ideal diagnostic system should provide real-time monitoring of the "health" of the transmission, be capable of a high level of reliable detection (with minimization of false alarms), and provide human users with clear information on the health of the system without making it necessary for them to interpret large amounts of sensor data.

  7. Trace detection of perchlorate in industrial-grade emulsion explosive with portable surface-enhanced Raman spectroscopy.

    PubMed

    Nuntawong, N; Eiamchai, P; Limwichean, S; Wong-ek, B; Horprathum, M; Patthanasettakul, V; Leelapojanaporn, A; Nakngoenthong, S; Chindaudom, P

    2013-12-10

    Recent analyses by ion-exchange chromatography (IC) showed that, beside nitrate, the majority of the industrial-grade emulsion explosives, extensively used by most separatists in the southern Thailand insurgency, contained small traces of perchlorate anions. In demand for the faster, reliable, and simple detection methods, the portable detection of nitrate and perchlorate became the great interest for the forensic and field-investigators. This work proposed a unique method to detect the trace amount of perchlorate in seven industrial-grade emulsion explosives under the field tests. We utilized the combination of the portable Raman spectroscope, the developed surfaced-enhanced Raman substrates, and the sample preparation procedures. The portable Raman spectroscope with a laser diode of 785 nm for excitation and a thermoelectric-cooled CCD spectrometer for detection was commercially available. The SERS substrates, with uniformly distributed nanostructured silver nanorods, were fabricated by the DC magnetron sputtering system, based on the oblique-angle deposition technique. The sample preparation procedures were proposed based on (1) pentane extraction technique and (2) combustion technique, prior to being dissolved in the purified water. In comparison to the ion chromatography and the conventional Raman measurements, our proposed methods successfully demonstrated the highly sensitive detectability of the minimal trace amount of perchlorate from five of the explosives with minimal operating time. This work was therefore highly practical to the development for the forensic analyses of the post-blast explosive residues under the field-investigations. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  8. Advances in analytical technologies for environmental protection and public safety.

    PubMed

    Sadik, O A; Wanekaya, A K; Andreescu, S

    2004-06-01

    Due to the increased threats of chemical and biological agents of injury by terrorist organizations, a significant effort is underway to develop tools that can be used to detect and effectively combat chemical and biochemical toxins. In addition to the right mix of policies and training of medical personnel on how to recognize symptoms of biochemical warfare agents, the major success in combating terrorism still lies in the prevention, early detection and the efficient and timely response using reliable analytical technologies and powerful therapies for minimizing the effects in the event of an attack. The public and regulatory agencies expect reliable methodologies and devices for public security. Today's systems are too bulky or slow to meet the "detect-to-warn" needs for first responders such as soldiers and medical personnel. This paper presents the challenges in monitoring technologies for warfare agents and other toxins. It provides an overview of how advances in environmental analytical methodologies could be adapted to design reliable sensors for public safety and environmental surveillance. The paths to designing sensors that meet the needs of today's measurement challenges are analyzed using examples of novel sensors, autonomous cell-based toxicity monitoring, 'Lab-on-a-Chip' devices and conventional environmental analytical techniques. Finally, in order to ensure that the public and legal authorities are provided with quality data to make informed decisions, guidelines are provided for assessing data quality and quality assurance using the United States Environmental Protection Agency (US-EPA) methodologies.

  9. Measurement Properties of the NIH-Minimal Dataset Dutch Language Version in Patients With Chronic Low Back Pain.

    PubMed

    Boer, Annemarie; Dutmer, Alisa L; Schiphorst Preuper, Henrica R; van der Woude, Lucas H V; Stewart, Roy E; Deyo, Richard A; Reneman, Michiel F; Soer, Remko

    2017-10-01

    Validation study with cross-sectional and longitudinal measurements. To translate the US National Institutes of Health (NIH)-minimal dataset for clinical research on chronic low back pain into the Dutch language and to test its validity and reliability among people with chronic low back pain. The NIH developed a minimal dataset to encourage more complete and consistent reporting of clinical research and to be able to compare studies across countries in patients with low back pain. In the Netherlands, the NIH-minimal dataset has not been translated before and measurement properties are unknown. Cross-cultural validity was tested by a formal forward-backward translation. Structural validity was tested with exploratory factor analyses (comparative fit index, Tucker-Lewis index, and root mean square error of approximation). Hypothesis testing was performed to compare subscales of the NIH dataset with the Pain Disability Index and the EurQol-5D (Pearson correlation coefficients). Internal consistency was tested with Cronbach α and test-retest reliability at 2 weeks was calculated in a subsample of patients with Intraclass Correlation Coefficients and weighted Kappa (κω). In total, 452 patients were included of which 52 were included for the test-retest study. factor analysis for structural validity pointed into the direction of a seven-factor model (Cronbach α = 0.78). Factors and total score of the NIH-minimal dataset showed fair to good correlations with Pain Disability Index (r = 0.43-0.70) and EuroQol-5D (r = -0.41 to -0.64). Reliability: test-retest reliability per item showed substantial agreement (κω=0.65). Test-retest reliability per factor was moderate to good (Intraclass Correlation Coefficient = 0.71). The Dutch language version measurement properties of the NIH-minimal were satisfactory. N/A.

  10. X-Ray Computed Tomography: The First Step in Mars Sample Return Processing

    NASA Technical Reports Server (NTRS)

    Welzenbach, L. C.; Fries, M. D.; Grady, M. M.; Greenwood, R. C.; McCubbin, F. M.; Zeigler, R. A.; Smith, C. L.; Steele, A.

    2017-01-01

    The Mars 2020 rover mission will collect and cache samples from the martian surface for possible retrieval and subsequent return to Earth. If the samples are returned, that mission would likely present an opportunity to analyze returned Mars samples within a geologic context on Mars. In addition, it may provide definitive information about the existence of past or present life on Mars. Mars sample return presents unique challenges for the collection, containment, transport, curation and processing of samples [1] Foremost in the processing of returned samples are the closely paired considerations of life detection and Planetary Protection. In order to achieve Mars Sample Return (MSR) science goals, reliable analyses will depend on overcoming some challenging signal/noise-related issues where sparse martian organic compounds must be reliably analyzed against the contamination background. While reliable analyses will depend on initial clean acquisition and robust documentation of all aspects of developing and managing the cache [2], there needs to be a reliable sample handling and analysis procedure that accounts for a variety of materials which may or may not contain evidence of past or present martian life. A recent report [3] suggests that a defined set of measurements should be made to effectively inform both science and Planetary Protection, when applied in the context of the two competing null hypotheses: 1) that there is no detectable life in the samples; or 2) that there is martian life in the samples. The defined measurements would include a phased approach that would be accepted by the community to preserve the bulk of the material, but provide unambiguous science data that can be used and interpreted by various disciplines. Fore-most is the concern that the initial steps would ensure the pristine nature of the samples. Preliminary, non-invasive techniques such as computed X-ray tomography (XCT) have been suggested as the first method to interrogate and characterize the cached samples without altering the materials [1,2]. A recent report [4] indicates that XCT may minimally alter samples for some techniques, and work is needed to quantify these effects, maximizing science return from XCT initial analysis while minimizing effects.

  11. Automated detection of optical counterparts to GRBs with RAPTOR

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wozniak, P. R.; Vestrand, W. T.; Evans, S.

    2006-05-19

    The RAPTOR system (RAPid Telescopes for Optical Response) is an array of several distributed robotic telescopes that automatically respond to GCN localization alerts. Raptor-S is a 0.4-m telescope with 24 arc min. field of view employing a 1k x 1k Marconi CCD detector, and has already detected prompt optical emission from several GRBs within the first minute of the explosion. We present a real-time data analysis and alert system for automated identification of optical transients in Raptor-S GRB response data down to the sensitivity limit of {approx} 19 mag. Our custom data processing pipeline is designed to minimize the timemore » required to reliably identify transients and extract actionable information. The system utilizes a networked PostgreSQL database server for catalog access and distributes email alerts with successful detections.« less

  12. Feature-based registration of historical aerial images by Area Minimization

    NASA Astrophysics Data System (ADS)

    Nagarajan, Sudhagar; Schenk, Toni

    2016-06-01

    The registration of historical images plays a significant role in assessing changes in land topography over time. By comparing historical aerial images with recent data, geometric changes that have taken place over the years can be quantified. However, the lack of ground control information and precise camera parameters has limited scientists' ability to reliably incorporate historical images into change detection studies. Other limitations include the methods of determining identical points between recent and historical images, which has proven to be a cumbersome task due to continuous land cover changes. Our research demonstrates a method of registering historical images using Time Invariant Line (TIL) features. TIL features are different representations of the same line features in multi-temporal data without explicit point-to-point or straight line-to-straight line correspondence. We successfully determined the exterior orientation of historical images by minimizing the area formed between corresponding TIL features in recent and historical images. We then tested the feasibility of the approach with synthetic and real data and analyzed the results. Based on our analysis, this method shows promise for long-term 3D change detection studies.

  13. Inter-rater Reliability of Real-Time Ultrasound to Measure Acromiohumeral Distance.

    PubMed

    Mackenzie, Tanya Anne; Bdaiwi, Alya H; Herrington, Lee; Cools, Ann

    2016-07-01

    Real-time ultrasound (RTUS) has been suggested as a reliable measure of acromiohumeral distance. However, to date, no vigorous assessment and reporting of inter-rater reliability of this method has been performed with the shoulder in a neutral position or with active and passive arm abduction. To assess intrasession inter-rater reliability of using RTUS to measure acromiohumeral distance with the shoulder in a neutral position and with 60° active and passive abduction. Inter-rater intrasession reliability of repeated measures. Human performance laboratory. Twenty persons (12 male and 8 female) with an average age of 29.86 years (standard deviation, 7.8). In an inter-rater, intrasession study, RTUS was used to measure the acromiohumeral distance with the shoulder in a neutral position and with 60° of both active and passive abduction. Acromiohumeral distance. Intraclass correlation coefficient (ICC)2.1 scores ranged between 0.65-0.88 (standard error of the mean = 0.81-1.2 mm and minimal detectable differences with 95% confidence = 2.2-2.3 mm) for inter-rater intrasession reliability. RTUS was found to have fair to good inter-rater reliability as a tool to measure acromiohumeral distance with the shoulder in a neutral position and with 60° of both active and passive arm abduction. Copyright © 2016 American Academy of Physical Medicine and Rehabilitation. Published by Elsevier Inc. All rights reserved.

  14. Basic psychometric properties of the transfer assessment instrument (version 3.0).

    PubMed

    Tsai, Chung-Ying; Rice, Laura A; Hoelmer, Claire; Boninger, Michael L; Koontz, Alicia M

    2013-12-01

    To refine the Transfer Assessment Instrument (TAI 2.0), develop a training program for the TAI, and analyze the basic psychometric properties of the TAI 3.0, including reliability, standard error of measurement (SEM), minimal detectable change (MDC), and construct validity. Repeated measures. A winter sports clinic for disabled veterans. Wheelchair users (N=41) who perform sitting-pivot or standing-pivot transfers. Not applicable. TAI version 3.0, intraclass correlation coefficients, SEMs, and MDCs for reliable measurement of raters' responses. Spearman correlation coefficient, 1-way analysis of variance, and independent t tests to evaluate construct validity. TAI 3.0 had acceptable to high levels of reliability (range, .74-.88). The SEMs for part 1, part 2, and final scores ranged from .45 to .75. The MDC was 1.5 points on the 10-point scale for the final score. There were weak correlations (ρ range, -.13 to .25; P>.11) between TAI final scores and subjects' characteristics (eg, sex, body mass index, age, type of disability, length of wheelchair use, grip and elbow strength, sitting balance). With comprehensive training, the refined TAI 3.0 yields high reliability among raters of different clinical backgrounds and experience. TAI 3.0 was unbiased toward certain physical characteristics that may influence transfer. TAI fills a void in the field by providing a quantitative measurement of transfers and a tool that can be used to detect problems and guide transfer training. Copyright © 2013 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  15. Practical Procedures for Constructing Mastery Tests to Minimize Errors of Classification and to Maximize or Optimize Decision Reliability.

    ERIC Educational Resources Information Center

    Byars, Alvin Gregg

    The objectives of this investigation are to develop, describe, assess, and demonstrate procedures for constructing mastery tests to minimize errors of classification and to maximize decision reliability. The guidelines are based on conditions where item exchangeability is a reasonable assumption and the test constructor can control the number of…

  16. Validation Test Results for Orthogonal Probe Eddy Current Thruster Inspection System

    NASA Technical Reports Server (NTRS)

    Wincheski, Russell A.

    2007-01-01

    Recent nondestructive evaluation efforts within NASA have focused on an inspection system for the detection of intergranular cracking originating in the relief radius of Primary Reaction Control System (PCRS) Thrusters. Of particular concern is deep cracking in this area which could lead to combustion leakage in the event of through wall cracking from the relief radius into an acoustic cavity of the combustion chamber. In order to reliably detect such defects while ensuring minimal false positives during inspection, the Orthogonal Probe Eddy Current (OPEC) system has been developed and an extensive validation study performed. This report describes the validation procedure, sample set, and inspection results as well as comparing validation flaws with the response from naturally occuring damage.

  17. Relationship between cardiac quiescent periods derived from seismocardiography and echocardiography.

    PubMed

    Wick, Carson A; Inan, Omer T; Bhatti, Pamela; Tridandapani, Srini

    2015-08-01

    The seismocardiogram (SCG) is a measure of chest wall acceleration due to cardiac motion that could potentially supplement the electrocardiogram (ECG) to more reliably predict cardiac quiescence. Accurate prediction is critical for modalities requiring minimal motion during imaging data acquisition, such as cardiac computed tomography (CT) and magnetic resonance imaging (MRI). For seven healthy subjects, SCG and B-mode echocardiography were used to identify quiescent periods on a beat-by-beat basis. Quiescent periods were detected as time intervals when the magnitude of the velocity signals calculated from SCG and echocardiography were less than a specified threshold. The quiescent periods detected from SCG were compared to those detected from B-mode echocardiography. The quiescent periods of the SCG were found to occur before those detected by echocardiography. A linear relationship between the delay from SCG- to echocardiography-detected phases with respect to heart rate was found. This delay could potentially be used to predict cardiac quiescence from SCG-observed quiescence for use with cardiac imaging modalities such as CT and MRI.

  18. Current and Developing Technologies for Monitoring Agents of Bioterrorism and Biowarfare

    PubMed Central

    Lim, Daniel V.; Simpson, Joyce M.; Kearns, Elizabeth A.; Kramer, Marianne F.

    2005-01-01

    Recent events have made public health officials acutely aware of the importance of rapidly and accurately detecting acts of bioterrorism. Because bioterrorism is difficult to predict or prevent, reliable platforms to rapidly detect and identify biothreat agents are important to minimize the spread of these agents and to protect the public health. These platforms must not only be sensitive and specific, but must also be able to accurately detect a variety of pathogens, including modified or previously uncharacterized agents, directly from complex sample matrices. Various commercial tests utilizing biochemical, immunological, nucleic acid, and bioluminescence procedures are currently available to identify biological threat agents. Newer tests have also been developed to identify such agents using aptamers, biochips, evanescent wave biosensors, cantilevers, living cells, and other innovative technologies. This review describes these current and developing technologies and considers challenges to rapid, accurate detection of biothreat agents. Although there is no ideal platform, many of these technologies have proved invaluable for the detection and identification of biothreat agents. PMID:16223949

  19. Interhemispheric Inhibition Measurement Reliability in Stroke: A Pilot Study

    PubMed Central

    Cassidy, Jessica M.; Chu, Haitao; Chen, Mo; Kimberley, Teresa J.; Carey, James R.

    2016-01-01

    Objective Reliable transcranial magnetic stimulation (TMS) measures for probing corticomotor excitability are important when assessing the physiological effects of non-invasive brain stimulation. The primary objective of this study was to examine test-retest reliability of an interhemispheric inhibition (IHI) index measurement in stroke. Materials and Methods Ten subjects with chronic stroke (≥ 6 months) completed two IHI testing sessions per week for three weeks (six testing sessions total). A single investigator measured IHI in the contra- to-ipsilesional primary motor cortex direction and in the opposite direction using bilateral paired-pulse TMS. Weekly sessions were separated by 24 hours with a 1-week washout period separating testing weeks. To determine if motor-evoked potential (MEP) quantification method affected measurement reliability, IHI indices computed from both MEP amplitude and area responses were found. Reliability was assessed with two-way, mixed intraclass correlation coefficients (ICC(3,k)). Standard error of measurement and minimal detectable difference statistics were also determined. Results With the exception of the initial testing week, IHI indices measured in the contra-to-ipsilesional hemisphere direction demonstrated moderate to excellent reliability (ICC = 0.725 – 0.913). Ipsi-to-contralesional IHI indices depicted poor or invalid reliability estimates throughout the three-week testing duration (ICC= −1.153 – 0.105). The overlap of ICC 95% confidence intervals suggested that IHI indices using MEP amplitude vs. area measures did not differ with respect to reliability. Conclusions IHI indices demonstrated varying magnitudes of reliability irrespective of MEP quantification method. Several strategies for improving IHI index measurement reliability are discussed. PMID:27333364

  20. Reliability of ultrasound thickness measurement of the abdominal muscles during clinical isometric endurance tests.

    PubMed

    ShahAli, Shabnam; Arab, Amir Massoud; Talebian, Saeed; Ebrahimi, Esmaeil; Bahmani, Andia; Karimi, Noureddin; Nabavi, Hoda

    2015-07-01

    The study was designed to evaluate the intra-examiner reliability of ultrasound (US) thickness measurement of abdominal muscles activity when supine lying and during two isometric endurance tests in subjects with and without Low back pain (LBP). A total of 19 women (9 with LBP, 10 without LBP) participated in the study. Within-day reliability of the US thickness measurements at supine lying and the two isometric endurance tests were assessed in all subjects. The intra-class correlation coefficient (ICC) was used to assess the relative reliability of thickness measurement. The standard error of measurement (SEM), minimal detectable change (MDC) and the coefficient of variation (CV) were used to evaluate the absolute reliability. Results indicated high ICC scores (0.73-0.99) and also small SEM and MDC scores for within-day reliability assessment. The Bland-Altman plots of agreement in US measurement of the abdominal muscles during the two isometric endurance tests demonstrated that 95% of the observations fall between the limits of agreement for test and retest measurements. Together the results indicate high intra-tester reliability for the US measurement of the thickness of abdominal muscles in all the positions tested. According to the study's findings, US imaging can be used as a reliable method for assessment of abdominal muscles activity in supine lying and the two isometric endurance tests employed, in participants with and without LBP. Copyright © 2014 Elsevier Ltd. All rights reserved.

  1. Reliability analysis of a sensitive and independent stabilometry parameter set

    PubMed Central

    Nagymáté, Gergely; Orlovits, Zsanett

    2018-01-01

    Recent studies have suggested reduced independent and sensitive parameter sets for stabilometry measurements based on correlation and variance analyses. However, the reliability of these recommended parameter sets has not been studied in the literature or not in every stance type used in stabilometry assessments, for example, single leg stances. The goal of this study is to evaluate the test-retest reliability of different time-based and frequency-based parameters that are calculated from the center of pressure (CoP) during bipedal and single leg stance for 30- and 60-second measurement intervals. Thirty healthy subjects performed repeated standing trials in a bipedal stance with eyes open and eyes closed conditions and in a single leg stance with eyes open for 60 seconds. A force distribution measuring plate was used to record the CoP. The reliability of the CoP parameters was characterized by using the intraclass correlation coefficient (ICC), standard error of measurement (SEM), minimal detectable change (MDC), coefficient of variation (CV) and CV compliance rate (CVCR). Based on the ICC, SEM and MDC results, many parameters yielded fair to good reliability values, while the CoP path length yielded the highest reliability (smallest ICC > 0.67 (0.54–0.79), largest SEM% = 19.2%). Usually, frequency type parameters and extreme value parameters yielded poor reliability values. There were differences in the reliability of the maximum CoP velocity (better with 30 seconds) and mean power frequency (better with 60 seconds) parameters between the different sampling intervals. PMID:29664938

  2. Reliability analysis of a sensitive and independent stabilometry parameter set.

    PubMed

    Nagymáté, Gergely; Orlovits, Zsanett; Kiss, Rita M

    2018-01-01

    Recent studies have suggested reduced independent and sensitive parameter sets for stabilometry measurements based on correlation and variance analyses. However, the reliability of these recommended parameter sets has not been studied in the literature or not in every stance type used in stabilometry assessments, for example, single leg stances. The goal of this study is to evaluate the test-retest reliability of different time-based and frequency-based parameters that are calculated from the center of pressure (CoP) during bipedal and single leg stance for 30- and 60-second measurement intervals. Thirty healthy subjects performed repeated standing trials in a bipedal stance with eyes open and eyes closed conditions and in a single leg stance with eyes open for 60 seconds. A force distribution measuring plate was used to record the CoP. The reliability of the CoP parameters was characterized by using the intraclass correlation coefficient (ICC), standard error of measurement (SEM), minimal detectable change (MDC), coefficient of variation (CV) and CV compliance rate (CVCR). Based on the ICC, SEM and MDC results, many parameters yielded fair to good reliability values, while the CoP path length yielded the highest reliability (smallest ICC > 0.67 (0.54-0.79), largest SEM% = 19.2%). Usually, frequency type parameters and extreme value parameters yielded poor reliability values. There were differences in the reliability of the maximum CoP velocity (better with 30 seconds) and mean power frequency (better with 60 seconds) parameters between the different sampling intervals.

  3. Interrater and Test-Retest Reliability and Minimal Detectable Change of the Balance Evaluation Systems Test (BESTest) and Subsystems With Community-Dwelling Older Adults.

    PubMed

    Wang-Hsu, Elizabeth; Smith, Susan S

    2017-01-10

    Falls are a common cause of injuries and hospital admissions in older adults. Balance limitation is a potentially modifiable factor contributing to falls. The Balance Evaluation Systems Test (BESTest), a clinical balance measure, categorizes balance into 6 underlying subsystems. Each of the subsystems is scored individually and summed to obtain a total score. The reliability of the BESTest and its individual subsystems has been reported in patients with various neurological disorders and cancer survivors. However, the reliability and minimal detectable change (MDC) of the BESTest with community-dwelling older adults have not been reported. The purposes of our study were to (1) determine the interrater and test-retest reliability of the BESTest total and subsystem scores; and (2) estimate the MDC of the BESTest and its individual subsystem scores with community-dwelling older adults. We used a prospective cohort methodological design. Community-dwelling older adults (N = 70; aged 70-94 years; mean = 85.0 [5.5] years) were recruited from a senior independent living community. Trained testers (N = 3) administered the BESTest. All participants were tested with the BESTest by the same tester initially and then retested 7 to 14 days later. With 32 of the participants, a second tester concurrently scored the retest for interrater reliability. Testers were blinded to each other's scores. Intraclass correlation coefficients [ICC(2,1)] were used to determine the interrater and test-retest reliability. Test-retest reliability was also analyzed using method error and the associated coefficients of variation (CVME). MDC was calculated using standard error of measurement. Interrater reliability (N = 32) of the BESTest total score was ICC(2, 1) = 0.97 (95% confidence interval [CI], 0.94-0.99). The ICCs for the individual subsystem scores ranged from 0.85 to 0.94. Test-retest reliability (N = 70) of the BESTest total score was ICC(2,1) = 0.93 (95% CI, 0.89-0.96). ICCs for the individual subsystem scores ranged from 0.72 to 0.89. The CVME (N = 70) of the BESTest total score was 4.1%. The CVME for the subsystem scores ranged from 5.0% to 10.7%. MDC (N = 70) for the BESTest total score at the 95% CI was 7.6%, or 8.2 points. MDC at the 95% CI for subsystem scores ranged from 11.7% to 19.0% (2.1-3.4 points). Results demonstrated generally good to excellent interrater and test-retest reliability in both the BESTest total and subsystem scores with community-dwelling older adults. The BESTest total and individual subsystem scores demonstrate good to excellent interrater and test-retest reliability with community-dwelling older adults. A change of 7.6% (8.2 points) or more in the BESTest total and a percentage change ranged from 11.7% to 19.0% (2.1-3.4 points) in the subsystem scores are suggested for clinicians to be 95% confident of true change when evaluating change in this population.

  4. Minimal detectable change of the actual amount of use test and the motor activity log: the EXCITE Trial.

    PubMed

    Chen, Shuya; Wolf, Steven L; Zhang, Qin; Thompson, Paul A; Winstein, Carolee J

    2012-06-01

    Efficacy of task-oriented training can be reliably trusted only when the inherent measurement variability is determined. The Actual Amount of Use Test (AAUT) and the Motor Activity Log (MAL) have been used together as measures of spontaneous arm use after an intervention; however, the minimal detectable change (MDC) of AAUT and MAL has not been addressed. To compare the MDC₉₀ of the AAUT and the MAL in the context of a randomized controlled trial of a neurorehabilitation intervention, the Extremity Constraint-Induced Therapy Evaluation trial. A preplanned secondary analysis was conducted using pre-post test data from the control group. Estimated MDC₉₀ were normalized to the maximum value of the scale of the AAUT and the MAL for each subscale: amount of use (AAUTa, MALa) and quality of movement (AAUTq, MALq). . The MDC₉₀ of the AAUTq and the MALq were 14.4% and 15.4%, respectively. However, the MDC₉₀ required greater change for the AAUTa (24.2%) than the MALa (16.8%). The training-induced spontaneous arm use exceeded the MDC₉₀ for the MAL but fell below that for the AAUT immediately after the intervention and at 1-year follow-up visit. The greater variability and insensitivity to treatment effect for the AAUTa is likely because of the low resolution of its scoring system. As such, there is a considerable need to develop valid and reliable tools that capture purposeful arm use outside the laboratory, perhaps through leveraging new sensing technologies with objective activity monitoring.

  5. A minimal standardization setting for language mapping tests: an Italian example.

    PubMed

    Rofes, Adrià; de Aguiar, Vânia; Miceli, Gabriele

    2015-07-01

    During awake surgery, picture-naming tests are administered to identify brain structures related to language function (language mapping), and to avoid iatrogenic damage. Before and after surgery, naming tests and other neuropsychological procedures aim at charting naming abilities, and at detecting which items the subject can respond to correctly. To achieve this goal, sufficiently large samples of normed and standardized stimuli must be available for preoperative and postoperative testing, and to prepare intraoperative tasks, the latter only including items named flawlessly preoperatively. To discuss design, norming and presentation of stimuli, and to describe the minimal standardization setting used to develop two sets of Italian stimuli, one for object naming and one for verb naming, respectively. The setting includes a naming study (to obtain picture-name agreement ratings), two on-line questionnaires (to acquire age-of-acquisition and imageability ratings for all test items), and the norming of other relevant language variables. The two sets of stimuli have >80 % picture-name agreement, high levels of internal consistency and reliability for imageability and age of acquisition ratings. They are normed for psycholinguistic variables known to affect lexical access and retrieval, and are validated in a clinical population. This framework can be used to increase the probability of reliably detecting language impairments before and after surgery, to prepare intraoperative tests based on sufficient knowledge of pre-surgical language abilities in each patient, and to decrease the probability of false positives during surgery. Examples of data usage are provided. Normative data can be found in the supplementary materials.

  6. Minimal Detectable Change of the Actual Amount of Use Test and the Motor Activity Log: The EXCITE Trial

    PubMed Central

    Chen, Shuya; Wolf, Steven L.; Zhang, Qin; Thompson, Paul A.; Winstein, Carolee J.

    2013-01-01

    Background Efficacy of task-oriented training can be reliably trusted only when the inherent measurement variability is determined. The Actual Amount of Use Test (AAUT) and the Motor Activity Log (MAL) have been used together as measures of spontaneous arm use after an intervention; however, the minimal detectable change (MDC) of AAUT and MAL has not been addressed. Objective To compare the MDC90 of the AAUT and the MAL in the context of a randomized controlled trial of a neurorehabilitation intervention, the Extremity Constraint-Induced Therapy Evaluation trial. Methods A preplanned secondary analysis was conducted using pre–post test data from the control group. Estimated MDC90 were normalized to the maximum value of the scale of the AAUT and the MAL for each subscale: amount of use (AAUTa, MALa) and quality of movement (AAUTq, MALq). Results The MDC90 of the AAUTq and the MALq were 14.4% and 15.4%, respectively. However, the MDC90 required greater change for the AAUTa (24.2%) than the MALa (16.8%). The training-induced spontaneous arm use exceeded the MDC90 for the MAL but fell below that for the AAUT immediately after the intervention and at 1-year follow-up visit. Conclusions The greater variability and insensitivity to treatment effect for the AAUTa is likely because of the low resolution of its scoring system. As such, there is a considerable need to develop valid and reliable tools that capture purposeful arm use outside the laboratory, perhaps through leveraging new sensing technologies with objective activity monitoring. PMID:22275157

  7. Phospholipase C mediated Suppression of Dark Noise Enables Single Photon Detection in Drosophila Photoreceptors

    PubMed Central

    Katz, Ben; Minke, Baruch

    2012-01-01

    Drosophila photoreceptor cells use the ubiquitous G-protein-mediated phospholipase C (PLC) cascade to achieve ultimate single photon sensitivity. This is manifested in the single photon responses (quantum bumps). In photoreceptor cells, dark activation of Gqα molecules occurs spontaneously and produces unitary dark events (dark bumps). A high rate of spontaneous Gqα activation and dark bump production potentially hampers single photon detection. We found that in wild type flies the in vivo rate of spontaneous Gqα activation is very high. Nevertheless, this high rate is not manifested in a substantially high rate of dark bumps. Therefore, it is unclear how phototransduction suppresses dark bump production, arising from spontaneous Gqα activation, while still maintaining high-fidelity representation of single photons. In this study we show that reduced PLC catalytic activity selectively suppressed production of dark bumps but not light-induced bumps. Manipulations of PLC activity using PLC mutant flies and Ca2+ modulations revealed that a critical level of PLC activity is required to induce bump production. The required minimal level of PLC activity, selectively suppressed random production of single Gqα-activated dark bumps despite a high rate of spontaneous Gqα activation. This minimal PLC activity level is reliably obtained by photon induced synchronized activation of several neighboring Gqα molecules activating several PLC molecules, but not by random activation of single Gqα molecules. We thus demonstrate how a G-protein-mediated transduction system, with PLC as its target, selectively suppresses its intrinsic noise while preserving reliable signaling. PMID:22357856

  8. Automatic Detection of Mitosis and Nuclei From Cytogenetic Images by CellProfiler Software for Mitotic Index Estimation.

    PubMed

    González, Jorge Ernesto; Radl, Analía; Romero, Ivonne; Barquinero, Joan Francesc; García, Omar; Di Giorgio, Marina

    2016-12-01

    Mitotic Index (MI) estimation expressed as percentage of mitosis plays an important role as quality control endpoint. To this end, MI is applied to check the lot of media and reagents to be used throughout the assay and also to check cellular viability after blood sample shipping, indicating satisfactory/unsatisfactory conditions for the progression of cell culture. The objective of this paper was to apply the CellProfiler open-source software for automatic detection of mitotic and nuclei figures from digitized images of cultured human lymphocytes for MI assessment, and to compare its performance to that performed through semi-automatic and visual detection. Lymphocytes were irradiated and cultured for mitosis detection. Sets of images from cultures were analyzed visually and findings were compared with those using CellProfiler software. The CellProfiler pipeline includes the detection of nuclei and mitosis with 80% sensitivity and more than 99% specificity. We conclude that CellProfiler is a reliable tool for counting mitosis and nuclei from cytogenetic images, saves considerable time compared to manual operation and reduces the variability derived from the scoring criteria of different scorers. The CellProfiler automated pipeline achieves good agreement with visual counting workflow, i.e. it allows fully automated mitotic and nuclei scoring in cytogenetic images yielding reliable information with minimal user intervention. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  9. Calculations of mechanisms for balance control during narrow and single-leg standing in fit older adults: A reliability study.

    PubMed

    Aberg, A C; Thorstensson, A; Tarassova, O; Halvorsen, K

    2011-07-01

    For older people balance control in standing is critical for performance of activities of daily living without falling. The aims were to investigate reliability of quantification of the usage of the two balance mechanisms M(1) 'moving the centre of pressure' and M(2) 'segment acceleration' and also to compare calculation methods based on a combination of kinetic (K) and kinematic (Km) data, (K-Km), or Km data only concerning M(2). For this purpose nine physically fit persons aged 70-78 years were tested in narrow and single-leg standing. Data were collected by a 7-camera motion capture system and two force plates. Repeated measure ANOVA and Tukey's post hoc tests were used to detect differences between the standing tasks. Reliability was estimated by ICCs, standard error of measurement including its 95% CI, and minimal detectable change, whereas Pearson's correlation coefficient was used to investigate agreement between the two calculation methods. The results indicated that for the tasks investigated, M(1) and M(2) can be measured with acceptable inter- and intrasession reliability, and that both Km and K-Km based calculations may be useful for M(2), although Km data may give slightly lower values. The proportional M(1):M(2) usage was approximately 9:1, in both anterio-posterior (AP) and medio-lateral (ML) directions for narrow standing, and about 2:1 in the AP and of 1:2 in the ML direction in single-leg standing, respectively. In conclusion, the tested measurements and calculations appear to constitute a reliable way of quantifying one important aspect of balance capacity in fit older people. Copyright © 2011 Elsevier B.V. All rights reserved.

  10. Mining protein interactomes to improve their reliability and support the advancement of network medicine.

    PubMed

    Alanis-Lobato, Gregorio

    2015-01-01

    High-throughput detection of protein interactions has had a major impact in our understanding of the intricate molecular machinery underlying the living cell, and has permitted the construction of very large protein interactomes. The protein networks that are currently available are incomplete and a significant percentage of their interactions are false positives. Fortunately, the structural properties observed in good quality social or technological networks are also present in biological systems. This has encouraged the development of tools, to improve the reliability of protein networks and predict new interactions based merely on the topological characteristics of their components. Since diseases are rarely caused by the malfunction of a single protein, having a more complete and reliable interactome is crucial in order to identify groups of inter-related proteins involved in disease etiology. These system components can then be targeted with minimal collateral damage. In this article, an important number of network mining tools is reviewed, together with resources from which reliable protein interactomes can be constructed. In addition to the review, a few representative examples of how molecular and clinical data can be integrated to deepen our understanding of pathogenesis are discussed.

  11. Reliability and criterion-related validity of a new repeated agility test

    PubMed Central

    Makni, E; Jemni, M; Elloumi, M; Chamari, K; Nabli, MA; Padulo, J; Moalla, W

    2016-01-01

    The study aimed to assess the reliability and the criterion-related validity of a new repeated sprint T-test (RSTT) that includes intense multidirectional intermittent efforts. The RSTT consisted of 7 maximal repeated executions of the agility T-test with 25 s of passive recovery rest in between. Forty-five team sports players performed two RSTTs separated by 3 days to assess the reliability of best time (BT) and total time (TT) of the RSTT. The intra-class correlation coefficient analysis revealed a high relative reliability between test and retest for BT and TT (>0.90). The standard error of measurement (<0.50) showed that the RSTT has a good absolute reliability. The minimal detectable change values for BT and TT related to the RSTT were 0.09 s and 0.58 s, respectively. To check the criterion-related validity of the RSTT, players performed a repeated linear sprint (RLS) and a repeated sprint with changes of direction (RSCD). Significant correlations between the BT and TT of the RLS, RSCD and RSTT were observed (p<0.001). The RSTT is, therefore, a reliable and valid measure of the intermittent repeated sprint agility performance. As this ability is required in all team sports, it is suggested that team sports coaches, fitness coaches and sports scientists consider this test in their training follow-up. PMID:27274109

  12. Reliability of tristimulus colourimetry in the assessment of cutaneous bruise colour.

    PubMed

    Scafide, Katherine N; Sheridan, Daniel J; Taylor, Laura A; Hayat, Matthew J

    2016-06-01

    Bruising is one of the most common types of injury clinicians observe among victims of violence and other trauma patients. However, research has shown commonly used qualitative description of cutaneous bruise colour via the naked eye is subjective and unreliable. No published work has formally evaluated the reliability of tristimulus colourimetry as an alternative for assessing bruise colour, despite its clinical and research applications in accurately assessing skin colour. The purpose of this study was to systematically evaluate the test-retest and inter-observer reliability of tristimulus colourimetry in the assessment of cutaneous bruise colour. Two researchers obtained repeated tristimulus colourimetry measures of cutaneous bruises with participants of diverse skin colour. Measures were obtained using the Minolta CR-400 Chomameter. Commission Internationale d'Eclairage (CIE) L*a*b* colour space was used. Data was analysed using intraclass correlation coefficients (ICC), Cronbach's alpha, and minimal detectable change (MDC) on all three L*a*b* values. The colorimeter demonstrated excellent test-retest or intra-rater reliability (L* ICC=0.999; a* ICC=0.973; b* ICC=0.892) and inter-rater reliability (L* ICC=0.997; a* ICC=0.976; b* ICC=0.982). With consistent placement, the tristimulus colourimetry is reliable for the objective assessment and documentation of cutaneous bruise colour for purposes of clinical practice and research. Recommendations for use in practice/research are provided. Copyright © 2016 Elsevier Ltd. All rights reserved.

  13. RETROSPECTIVE DETECTION OF INTERLEAVED SLICE ACQUISITION PARAMETERS FROM FMRI DATA

    PubMed Central

    Parker, David; Rotival, Georges; Laine, Andrew; Razlighi, Qolamreza R.

    2015-01-01

    To minimize slice excitation leakage to adjacent slices, interleaved slice acquisition is nowadays performed regularly in fMRI scanners. In interleaved slice acquisition, the number of slices skipped between two consecutive slice acquisitions is often referred to as the ‘interleave parameter’; the loss of this parameter can be catastrophic for the analysis of fMRI data. In this article we present a method to retrospectively detect the interleave parameter and the axis in which it is applied. Our method relies on the smoothness of the temporal-distance correlation function, which becomes disrupted along the axis on which interleaved slice acquisition is applied. We examined this method on simulated and real data in the presence of fMRI artifacts such as physiological noise, motion, etc. We also examined the reliability of this method in detecting different types of interleave parameters and demonstrated an accuracy of about 94% in more than 1000 real fMRI scans. PMID:26161244

  14. Assessing residual reasoning ability in overtly non-communicative patients using fMRI☆

    PubMed Central

    Hampshire, Adam; Parkin, Beth L.; Cusack, Rhodri; Espejo, Davinia Fernández; Allanson, Judith; Kamau, Evelyn; Pickard, John D.; Owen, Adrian M.

    2012-01-01

    It is now well established that some patients who are diagnosed as being in a vegetative state or a minimally conscious state show reliable signs of volition that may only be detected by measuring neural responses. A pertinent question is whether these patients are also capable of logical thought. Here, we validate an fMRI paradigm that can detect the neural fingerprint of reasoning processes and moreover, can confirm whether a participant derives logical answers. We demonstrate the efficacy of this approach in a physically non-communicative patient who had been shown to engage in mental imagery in response to simple auditory instructions. Our results demonstrate that this individual retains a remarkable capacity for higher cognition, engaging in the reasoning task and deducing logical answers. We suggest that this approach is suitable for detecting residual reasoning ability using neural responses and could readily be adapted to assess other aspects of cognition. PMID:24179769

  15. Neck motion kinematics: an inter-tester reliability study using an interactive neck VR assessment in asymptomatic individuals.

    PubMed

    Sarig Bahat, Hilla; Sprecher, Elliot; Sela, Itamar; Treleaven, Julia

    2016-07-01

    The use of virtual reality (VR) for assessment and intervention of neck pain has previously been used and shown reliable for cervical range of motion measures. Neck VR enables analysis of task-oriented neck movement by stimulating responsive movements to external stimuli. Therefore, the purpose of this study was to establish inter-tester reliability of neck kinematic measures so that it can be used as a reliable assessment and treatment tool between clinicians. This reliability study included 46 asymptomatic participants, who were assessed using the neck VR system which displayed an interactive VR scenario via a head-mounted device, controlled by neck movements. The objective of the interactive assessment was to hit 16 targets, randomly appearing in four directions, as fast as possible. Each participant was tested twice by two different testers. Good reliability was found of neck motion kinematic measures in flexion, extension, and rotation (0.64-0.93 inter-class correlation). High reliability was shown for peak velocity globally (0.93), in left rotation (0.9), right rotation and extension (0.88), and flexion (0.86). Mean velocity had a good global reliability (0.84), except for left rotation directed movement with moderate reliability (0.68). Minimal detectable change for peak velocity ranged from 41 to 53 °/s, while mean velocity ranged from 20 to 25 °/s. The results suggest high reliability for peak and mean velocity as measured by the interactive Neck VR assessment of neck motion kinematics. VR appears to provide a reliable and more ecologically valid method of cervical motion evaluation than previous conventional methodologies.

  16. Compact USB-powered mobile ELISA-based pathogen detection: design and implementation challenges

    NASA Astrophysics Data System (ADS)

    Starodubov, Dmitry; Asanbaeva, Anya; Berezhnyy, Ihor; Chao, Chung-Yen; Koziol, Richard; Miller, David; Patton, Edward; Trehan, Sushma; Ulmer, Chris

    2011-05-01

    Physical Optics Corporation (POC) presents a novel Mobile ELISA-based Pathogen Detection system that is based on a disposable microfluidic chip for multiple-threat detection and a highly sensitive portable microfluidic fluorescence measurement unit that also controls the flow of samples and reagents through the microfluidic channels of the chip. The fluorescence detection subsystem is composed of a commercial 635-nm diode laser, an avalanche photodiode (APD) that measures fluorescence, and three filtering mirrors that provide more than 100 dB of excitation line suppression in the signal detection channel. Special techniques to suppress the fluorescence and scattering background allow optimizing the dynamic range for a compact package. Concentrations below 100 ng/mL can be reliably identified. The entire instrument is powered using a USB port of a notebook PC and operates as a plug-and-play human-interface device, resulting in a truly peripheral biosensor. The operation of the system is fully automated, with minimal user intervention through the detection process. The resolved challenges of the design and implementation are presented in detail in this publication.

  17. Reliability of lower limb transcranial magnetic stimulation outcomes in the ipsi- and contralesional hemispheres of adults with chronic stroke.

    PubMed

    Beaulieu, Louis-David; Massé-Alarie, Hugo; Ribot-Ciscar, Edith; Schneider, Cyril

    2017-07-01

    To investigate the ability of transcranial magnetic stimulation (TMS) outcomes in the chronic stroke population to (i) track individual plastic changes and (ii) detect differences between individuals. To this end, intrarater "test-retest" reliability (relative and absolute) was tested for the ipsilesional and contralesional hemispheres. Thirteen participants with a unilateral stroke (≥6months ago) and sensorimotor impairments were enrolled. Single and paired-pulse TMS outcomes were obtained from the primary motor cortex (M1) representation of the tibialis anterior muscle in both hemispheres and at two sessions separated by one week. The standard error of the measurement (SEM eas ), minimal detectable change (MDC) and intraclass correlation coefficient (ICC) were studied. Active motor threshold and latency of motor evoked potentials provided the lowest SEM eas and highest ICCs for both ipsi- and contralesional hemispheres. However, MDC were generally large, thus questioning the use of TMS outcomes to track individual plastic changes of M1. Our study provided supporting evidence of good to excellent intrarater reliability for a few TMS outcomes and proposed recommendations on the interpretation and the use of that knowledge in future work. Psychometric properties of TMS measures should be further addressed in order to better understand how to refine their use in clinical settings. Copyright © 2017 International Federation of Clinical Neurophysiology. Published by Elsevier B.V. All rights reserved.

  18. Automation of servicibility of radio-relay station equipment

    NASA Astrophysics Data System (ADS)

    Uryev, A. G.; Mishkin, Y. I.; Itkis, G. Y.

    1985-03-01

    Automation of the serviceability of radio relay station equipment must ensure central gathering and primary processing of reliable instrument reading with subsequent display on the control panel, detection and recording of failures soon enough, advance enough warning based on analysis of detertioration symptoms, and correct remote measurement of equipment performance parameters. Such an inspection will minimize transmission losses while reducing nonproductive time and labor spent on documentation and measurement. A multichannel automated inspection system for this purpose should operate by a parallel rather than sequential procedure. Digital data processing is more expedient in this case than analog method and, therefore, analog to digital converters are required. Spepcial normal, above limit and below limit test signals provide means of self-inspection, to which must be added adequate interference immunization, stabilization, and standby power supply. Use of a microcomputer permits overall refinement and expansion of the inspection system while it minimizes though not completely eliminates dependence on subjective judgment.

  19. The kinematics of upper extremity reaching: a reliability study on people with and without shoulder impingement syndrome

    PubMed Central

    2010-01-01

    Background Tasks chosen to evaluate motor performance should reflect the movement deficits characteristic of the target population and present an appropriate challenge for the patients who would be evaluated. A reaching task that evaluates impairment characteristics of people with shoulder impingement syndrome (SIS) was developed to evaluate the motor performance of this population. The objectives of this study were to characterize the reproducibility of this reaching task in people with and without SIS and to evaluate the impact of the number of trials on reproducibility. Methods Thirty subjects with SIS and twenty healthy subjects participated in the first measurement session to evaluate intrasession reliability. Ten healthy subjects were retested within 2 to 7 days to assess intersession reliability. At each measurement session, upper extremity kinematic patterns were evaluated during a reaching task. Ten trials were recorded. Thereafter, the upper extremity position at the end of reaching and total joint excursion that occurred during reaching were calculated. Intraclass correlation coefficient (ICC) and minimal detectable change (MDC) were used to estimate intra and intersession reliability. Results Intrasession reliability for total joint excursion was good to very good when based on the first two trials (0.770.92). As for end-reach position, intrasession reliability was very good when using either the first two, first five or last five trials (ICC>0.82). Globally, MDC were smaller for the last five trials. Intersession reliability of total joint excursion and position at the end of reaching was good to very good when using the mean of the first two or five trials (0.690.82). For most joints, MDC were smaller when using all ten trials. Conclusions The reaching task proposed to evaluate the upper limb motor performance was found reliable in people with and without SIS. Furthermore, the minimal difference necessary to infer a meaningful change in motor performance was determined, indicating that relatively small changes in task performance can be interpreted as a change in motor performance. PMID:20331889

  20. Adaptive particle swarm optimization for optimal orbital elements of binary stars

    NASA Astrophysics Data System (ADS)

    Attia, Abdel-Fattah

    2016-12-01

    The paper presents an adaptive particle swarm optimization (APSO) as an alternative method to determine the optimal orbital elements of the star η Bootis of MK type G0 IV. The proposed algorithm transforms the problem of finding periodic orbits into the problem of detecting global minimizers as a function, to get a best fit of Keplerian and Phase curves. The experimental results demonstrate that the proposed approach of APSO generally more accurate than the standard particle swarm optimization (PSO) and other published optimization algorithms, in terms of solution accuracy, convergence speed and algorithm reliability.

  1. Fully integrated biochip platforms for advanced healthcare.

    PubMed

    Carrara, Sandro; Ghoreishizadeh, Sara; Olivo, Jacopo; Taurino, Irene; Baj-Rossi, Camilla; Cavallini, Andrea; de Beeck, Maaike Op; Dehollain, Catherine; Burleson, Wayne; Moussy, Francis Gabriel; Guiseppi-Elie, Anthony; De Micheli, Giovanni

    2012-01-01

    Recent advances in microelectronics and biosensors are enabling developments of innovative biochips for advanced healthcare by providing fully integrated platforms for continuous monitoring of a large set of human disease biomarkers. Continuous monitoring of several human metabolites can be addressed by using fully integrated and minimally invasive devices located in the sub-cutis, typically in the peritoneal region. This extends the techniques of continuous monitoring of glucose currently being pursued with diabetic patients. However, several issues have to be considered in order to succeed in developing fully integrated and minimally invasive implantable devices. These innovative devices require a high-degree of integration, minimal invasive surgery, long-term biocompatibility, security and privacy in data transmission, high reliability, high reproducibility, high specificity, low detection limit and high sensitivity. Recent advances in the field have already proposed possible solutions for several of these issues. The aim of the present paper is to present a broad spectrum of recent results and to propose future directions of development in order to obtain fully implantable systems for the continuous monitoring of the human metabolism in advanced healthcare applications.

  2. Fully Integrated Biochip Platforms for Advanced Healthcare

    PubMed Central

    Carrara, Sandro; Ghoreishizadeh, Sara; Olivo, Jacopo; Taurino, Irene; Baj-Rossi, Camilla; Cavallini, Andrea; de Beeck, Maaike Op; Dehollain, Catherine; Burleson, Wayne; Moussy, Francis Gabriel; Guiseppi-Elie, Anthony; De Micheli, Giovanni

    2012-01-01

    Recent advances in microelectronics and biosensors are enabling developments of innovative biochips for advanced healthcare by providing fully integrated platforms for continuous monitoring of a large set of human disease biomarkers. Continuous monitoring of several human metabolites can be addressed by using fully integrated and minimally invasive devices located in the sub-cutis, typically in the peritoneal region. This extends the techniques of continuous monitoring of glucose currently being pursued with diabetic patients. However, several issues have to be considered in order to succeed in developing fully integrated and minimally invasive implantable devices. These innovative devices require a high-degree of integration, minimal invasive surgery, long-term biocompatibility, security and privacy in data transmission, high reliability, high reproducibility, high specificity, low detection limit and high sensitivity. Recent advances in the field have already proposed possible solutions for several of these issues. The aim of the present paper is to present a broad spectrum of recent results and to propose future directions of development in order to obtain fully implantable systems for the continuous monitoring of the human metabolism in advanced healthcare applications. PMID:23112644

  3. Detection and management of minimal residual disease in acute lymphoblastic leukemia.

    PubMed

    Schrappe, Martin

    2014-12-05

    The detection of minimal residual disease (MRD) has become part of the state-of-the-art diagnostics to guide treatment both in pediatric and adult acute lymphoblastic leukemia (ALL). This applies to the treatment of de novo and recurrent ALL. In high-risk ALL, MRD detection is considered an important tool to adjust therapy before and after hematopoietic stem cell transplantation. Precise quantification and quality control is instrumental to avoid false treatment assignment. A new methodological approach to analyzing MRD has become available and is based on next-generation sequencing. In principle, this technique will be able to detect a large number of leukemic subclones at a much higher speed than before. Carefully designed prospective studies need to demonstrate concordance or even superiority compared with those techniques in use right now: detection of aberrant expression of leukemia-specific antigens by flow cytometry of blood or bone marrow, or detection of specific rearrangements of the T-cell receptor or immunoglobulin genes by real-time quantitative polymerase chain reaction using DNA of leukemic cells. In some cases with known fusion genes, such as BCR/ABL, reverse transcriptase-polymerase chain reaction has been used as additional method to identify leukemic cells by analyzing RNA in patient samples. MRD detection may be used to modulate treatment intensity once it has been demonstrated at well-defined informative checkpoints that certain levels of MRD can reliably predict the risk of relapse. In addition, MRD is used as end point to determine the activity of a given agent or treatment protocol. If activity translates into antileukemic efficacy, MRD may be considered a surrogate clinical end point. © 2014 by The American Society of Hematology. All rights reserved.

  4. Developing Reliable Life Support for Mars

    NASA Technical Reports Server (NTRS)

    Jones, Harry W.

    2017-01-01

    A human mission to Mars will require highly reliable life support systems. Mars life support systems may recycle water and oxygen using systems similar to those on the International Space Station (ISS). However, achieving sufficient reliability is less difficult for ISS than it will be for Mars. If an ISS system has a serious failure, it is possible to provide spare parts, or directly supply water or oxygen, or if necessary bring the crew back to Earth. Life support for Mars must be designed, tested, and improved as needed to achieve high demonstrated reliability. A quantitative reliability goal should be established and used to guide development t. The designers should select reliable components and minimize interface and integration problems. In theory a system can achieve the component-limited reliability, but testing often reveal unexpected failures due to design mistakes or flawed components. Testing should extend long enough to detect any unexpected failure modes and to verify the expected reliability. Iterated redesign and retest may be required to achieve the reliability goal. If the reliability is less than required, it may be improved by providing spare components or redundant systems. The number of spares required to achieve a given reliability goal depends on the component failure rate. If the failure rate is under estimated, the number of spares will be insufficient and the system may fail. If the design is likely to have undiscovered design or component problems, it is advisable to use dissimilar redundancy, even though this multiplies the design and development cost. In the ideal case, a human tended closed system operational test should be conducted to gain confidence in operations, maintenance, and repair. The difficulty in achieving high reliability in unproven complex systems may require the use of simpler, more mature, intrinsically higher reliability systems. The limitations of budget, schedule, and technology may suggest accepting lower and less certain expected reliability. A plan to develop reliable life support is needed to achieve the best possible reliability.

  5. Reliability and validity assessment of administrative databases in measuring the quality of rectal cancer management.

    PubMed

    Corbellini, Carlo; Andreoni, Bruno; Ansaloni, Luca; Sgroi, Giovanni; Martinotti, Mario; Scandroglio, Ildo; Carzaniga, Pierluigi; Longoni, Mauro; Foschi, Diego; Dionigi, Paolo; Morandi, Eugenio; Agnello, Mauro

    2018-01-01

    Measurement and monitoring of the quality of care using a core set of quality measures are increasing in health service research. Although administrative databases include limited clinical data, they offer an attractive source for quality measurement. The purpose of this study, therefore, was to evaluate the completeness of different administrative data sources compared to a clinical survey in evaluating rectal cancer cases. Between May 2012 and November 2014, a clinical survey was done on 498 Lombardy patients who had rectal cancer and underwent surgical resection. These collected data were compared with the information extracted from administrative sources including Hospital Discharge Dataset, drug database, daycare activity data, fee-exemption database, and regional screening program database. The agreement evaluation was performed using a set of 12 quality indicators. Patient complexity was a difficult indicator to measure for lack of clinical data. Preoperative staging was another suboptimal indicator due to the frequent missing administrative registration of tests performed. The agreement between the 2 data sources regarding chemoradiotherapy treatments was high. Screening detection, minimally invasive techniques, length of stay, and unpreventable readmissions were detected as reliable quality indicators. Postoperative morbidity could be a useful indicator but its agreement was lower, as expected. Healthcare administrative databases are large and real-time collected repositories of data useful in measuring quality in a healthcare system. Our investigation reveals that the reliability of indicators varies between them. Ideally, a combination of data from both sources could be used in order to improve usefulness of less reliable indicators.

  6. Reliability of the individual components of the Canadian Armed Forces Physical Employment Standard.

    PubMed

    Stockbrugger, Barry G; Reilly, Tara J; Blacklock, Rachel E; Gagnon, Patrick J

    2018-01-29

    This investigation recruited 24 participants from both the Canadian Armed Forces (CAF) and civilian populations to complete 4 separate trials at "best effort" of each of the 4 components in the CAF Physical Employment Standard named the FORCE Evaluation: Fitness for Operational Requirements of CAF Employment. Analyses were performed to examine the level of variability and reliability within each component. The results demonstrate that candidates should be provided with at least 1 retest if they have recently completed at least 2 previous best effort attempts as per the protocol. In addition, the minimal detectable difference is given for each of the 4 components in seconds which identifies the threshold for subsequent action, either retest or remedial training, for those unable to meet the minimum standard. These results will educate the delivery of this employment standard, function as a method of accommodation, in addition to providing direction for physical training programs.

  7. Reliability of self-reported weight and height among state bank employees.

    PubMed

    Chor, D; Coutinho, E da S; Laurenti, R

    1999-02-01

    Self-reported weight and height were compared with direct measurements in order to evaluate the agreement between the two sources. Data were obtained from a cross-sectional study on health status from a probabilistic sample of 1,183 employees of a bank, in Rio de Janeiro State, Brazil. Direct measurements were made of 322 employees. Differences between the two sources were evaluated using mean differences, limits of agreement and intraclass correlation coefficient (ICC). Men and women tended to underestimate their weight while differences between self-reported and measured height were insignificant. Body mass index (BMI) mean differences were smaller than those observed for weight. ICC was over 0.98 for weight and 0.95 for BMI, expressing close agreement. Combining a graphical method with ICC may be useful in pilot studies to detect populational groups capable of providing reliable information on weight and height, thus minimizing resources needed for field work.

  8. Reliable quantum certification of photonic state preparations

    PubMed Central

    Aolita, Leandro; Gogolin, Christian; Kliesch, Martin; Eisert, Jens

    2015-01-01

    Quantum technologies promise a variety of exciting applications. Even though impressive progress has been achieved recently, a major bottleneck currently is the lack of practical certification techniques. The challenge consists of ensuring that classically intractable quantum devices perform as expected. Here we present an experimentally friendly and reliable certification tool for photonic quantum technologies: an efficient certification test for experimental preparations of multimode pure Gaussian states, pure non-Gaussian states generated by linear-optical circuits with Fock-basis states of constant boson number as inputs, and pure states generated from the latter class by post-selecting with Fock-basis measurements on ancillary modes. Only classical computing capabilities and homodyne or hetorodyne detection are required. Minimal assumptions are made on the noise or experimental capabilities of the preparation. The method constitutes a step forward in many-body quantum certification, which is ultimately about testing quantum mechanics at large scales. PMID:26577800

  9. Cast Coil Transformer Fire Susceptibility and Reliability Study

    DTIC Science & Technology

    1991-04-01

    transformers reduce risk to the user compared to liquid-filled units, eliminate environmental impacts, are more efficient than most transformer designs, and...filled units, eliminate environmental impacts, arc more efficient than most transformer designs, and add minimal risk to the facility in a fire situation...add minimal risk to the facility in a fire situation. Cast coil transformers have a long record of operation and have proven to be reliable and

  10. Reliability and validity of CODA motion analysis system for measuring cervical range of motion in patients with cervical spondylosis and anterior cervical fusion.

    PubMed

    Gao, Zhongyang; Song, Hui; Ren, Fenggang; Li, Yuhuan; Wang, Dong; He, Xijing

    2017-12-01

    The aim of the present study was to evaluate the reliability of the Cartesian Optoelectronic Dynamic Anthropometer (CODA) motion system in measuring the cervical range of motion (ROM) and verify the construct validity of the CODA motion system. A total of 26 patients with cervical spondylosis and 22 patients with anterior cervical fusion were enrolled and the CODA motion analysis system was used to measure the three-dimensional cervical ROM. Intra- and inter-rater reliability was assessed by interclass correlation coefficients (ICCs), standard error of measurement (SEm), Limits of Agreements (LOA) and minimal detectable change (MDC). Independent samples t-tests were performed to examine the differences of cervical ROM between cervical spondylosis and anterior cervical fusion patients. The results revealed that in the cervical spondylosis group, the reliability was almost perfect (intra-rater reliability: ICC, 0.87-0.95; LOA, -12.86-13.70; SEm, 2.97-4.58; inter-rater reliability: ICC, 0.84-0.95; LOA, -13.09-13.48; SEm, 3.13-4.32). In the anterior cervical fusion group, the reliability was high (intra-rater reliability: ICC, 0.88-0.97; LOA, -10.65-11.08; SEm, 2.10-3.77; inter-rater reliability: ICC, 0.86-0.96; LOA, -10.91-13.66; SEm, 2.20-4.45). The cervical ROM in the cervical spondylosis group was significantly higher than that in the anterior cervical fusion group in all directions except for left rotation. In conclusion, the CODA motion analysis system is highly reliable in measuring cervical ROM and the construct validity was verified, as the system was sufficiently sensitive to distinguish between the cervical spondylosis and anterior cervical fusion groups based on their ROM.

  11. Exploiting sequence similarity to validate the sensitivity of SNP arrays in detecting fine-scaled copy number variations.

    PubMed

    Wong, Gerard; Leckie, Christopher; Gorringe, Kylie L; Haviv, Izhak; Campbell, Ian G; Kowalczyk, Adam

    2010-04-15

    High-density single nucleotide polymorphism (SNP) genotyping arrays are efficient and cost effective platforms for the detection of copy number variation (CNV). To ensure accuracy in probe synthesis and to minimize production costs, short oligonucleotide probe sequences are used. The use of short probe sequences limits the specificity of binding targets in the human genome. The specificity of these short probeset sequences has yet to be fully analysed against a normal reference human genome. Sequence similarity can artificially elevate or suppress copy number measurements, and hence reduce the reliability of affected probe readings. For the purpose of detecting narrow CNVs reliably down to the width of a single probeset, sequence similarity is an important issue that needs to be addressed. We surveyed the Affymetrix Human Mapping SNP arrays for probeset sequence similarity against the reference human genome. Utilizing sequence similarity results, we identified a collection of fine-scaled putative CNVs between gender from autosomal probesets whose sequence matches various loci on the sex chromosomes. To detect these variations, we utilized our statistical approach, Detecting REcurrent Copy number change using rank-order Statistics (DRECS), and showed that its performance was superior and more stable than the t-test in detecting CNVs. Through the application of DRECS on the HapMap population datasets with multi-matching probesets filtered, we identified biologically relevant SNPs in aberrant regions across populations with known association to physical traits, such as height, covered by the span of a single probe. This provided empirical confirmation of the existence of naturally occurring narrow CNVs as well as the sensitivity of the Affymetrix SNP array technology in detecting them. The MATLAB implementation of DRECS is available at http://ww2.cs.mu.oz.au/ approximately gwong/DRECS/index.html.

  12. Optimizing a neural network for detection of moving vehicles in video

    NASA Astrophysics Data System (ADS)

    Fischer, Noëlle M.; Kruithof, Maarten C.; Bouma, Henri

    2017-10-01

    In the field of security and defense, it is extremely important to reliably detect moving objects, such as cars, ships, drones and missiles. Detection and analysis of moving objects in cameras near borders could be helpful to reduce illicit trading, drug trafficking, irregular border crossing, trafficking in human beings and smuggling. Many recent benchmarks have shown that convolutional neural networks are performing well in the detection of objects in images. Most deep-learning research effort focuses on classification or detection on single images. However, the detection of dynamic changes (e.g., moving objects, actions and events) in streaming video is extremely relevant for surveillance and forensic applications. In this paper, we combine an end-to-end feedforward neural network for static detection with a recurrent Long Short-Term Memory (LSTM) network for multi-frame analysis. We present a practical guide with special attention to the selection of the optimizer and batch size. The end-to-end network is able to localize and recognize the vehicles in video from traffic cameras. We show an efficient way to collect relevant in-domain data for training with minimal manual labor. Our results show that the combination with LSTM improves performance for the detection of moving vehicles.

  13. Scanning, standoff TDLAS leak imaging and quantification

    NASA Astrophysics Data System (ADS)

    Wainner, Richard T.; Aubut, Nicholas F.; Laderer, Matthew C.; Frish, Michael B.

    2017-05-01

    This paper reports a novel quantitative gas plume imaging tool, based on active near-infrared Backscatter Tunable Diode Laser Absorption Spectroscopy (b-TDLAS) technology, designed for upstream natural gas leak applications. The new tool integrates low-cost laser sensors with video cameras to create a highly sensitive gas plume imager that also quantifies emission rate, all in a lightweight handheld ergonomic package. It is intended to serve as a lower-cost, higherperformance, enhanced functionality replacement for traditional passive non-quantitative mid-infrared Optical Gas Imagers (OGI) which are utilized by industry to comply with natural gas infrastructure Leak Detection and Repair (LDAR) requirements. It addresses the need for reliable, robust, low-cost sensors to detect and image methane leaks, and to quantify leak emission rates, focusing on inspections of upstream oil and gas operations, such as well pads, compressors, and gas plants. It provides: 1) Colorized quantified images of path-integrated methane concentration. The images depict methane plumes (otherwise invisible to the eye) actively interrogated by the laser beam overlaid on a visible camera image of the background. The detection sensitivity exceeds passive OGI, thus simplifying the manual task of leak detection and location; and 2) Data and algorithms for using the quantitative information gathered by the active detection technique to deduce plume flux (i.e. methane emission rate). This key capability will enable operators to prioritize leak repairs and thereby minimize the value of lost product, as well as to quantify and minimize greenhouse gas emissions, using a tool that meets EPA LDAR imaging equipment requirements.

  14. Computerized evaluation of holographic interferograms for fatigue crack detection in riveted lap joints

    NASA Astrophysics Data System (ADS)

    Zhou, Xiang

    Using an innovative portable holographic inspection and testing system (PHITS) developed at the Australian Defence Force Academy, fatigue cracks in riveted lap joints can be detected by visually inspecting the abnormal fringe changes recorded on holographic interferograms. In this thesis, for automatic crack detection, some modern digital image processing techniques are investigated and applied to holographic interferogram evaluation. Fringe analysis algorithms are developed for identification of the crack-induced fringe changes. Theoretical analysis of PHITS and riveted lap joints and two typical experiments demonstrate that the fatigue cracks in lightly-clamped joints induce two characteristic fringe changes: local fringe discontinuities at the cracking sites; and the global crescent fringe distribution near to the edge of the rivet hole. Both of the fringe features are used for crack detection in this thesis. As a basis of the fringe feature extraction, an algorithm for local fringe orientation calculation is proposed. For high orientation accuracy and computational efficiency, Gaussian gradient filtering and neighboring direction averaging are used to minimize the effects of image background variations and random noise. The neighboring direction averaging is also used to approximate the fringe directions in centerlines of bright and dark fringes. Experimental results indicate that for high orientation accuracy the scales of the Gaussian filter and neighboring direction averaging should be chosen according to the local fringe spacings. The orientation histogram technique is applied to detect the local fringe discontinuity due to the fatigue cracks. The Fourier descriptor technique is used to characterize the global fringe distribution change from a circular to a crescent distribution with the fatigue crack growth. Experiments and computer simulations are conducted to analyze the detectability and reliability of crack detection using the two techniques. Results demonstrate that the Fourier descriptor technique is more promising in the detection of the short cracks near the edge of the rivet head. However, it is not as reliable as the fringe orientation technique for detection of the long through cracks. For reliability, both techniques should be used in practical crack detection. Neither the Fourier descriptor technique nor the orientation histogram technique have been previously applied to holographic interferometry. While this work related primarily to interferograms of cracked rivets, the techniques would be readily applied to other areas of fringe pattern analysis.

  15. Robust Targeting for the Smartphone Video Guidance Sensor

    NASA Technical Reports Server (NTRS)

    Carter, Christopher

    2017-01-01

    The Smartphone Video Guidance Sensor (SVGS) is a miniature, self-contained autonomous rendezvous and docking sensor developed using a commercial off the shelf Android-based smartphone. It aims to provide a miniaturized solution for rendezvous and docking, enabling small satellites to conduct proximity operations and formation flying while minimizing interference with a primary payload. Previously, the sensor was limited by a slow (2 Hz) refresh rate and its use of retro-reflectors, both of which contributed to a limited operating environment. To advance the technology readiness level, a modified approach was developed, combining a multi-colored LED target with a focused target-detection algorithm. Alone, the use of an LED system was determined to be much more reliable, though slower, than the retro-reflector system. The focused target-detection system was developed in response to this problem to mitigate the speed reduction of using color. However, it also improved the reliability. In combination these two methods have been demonstrated to dramatically increase sensor speed and allow the sensor to select the target even with significant noise interfering with the sensor, providing millimeter level accuracy at a range of two meters with a 1U target.

  16. Robust Targeting for the Smartphone Video Guidance Sensor

    NASA Technical Reports Server (NTRS)

    Carter, C.

    2017-01-01

    The Smartphone Video Guidance Sensor (SVGS) is a miniature, self-contained autonomous rendezvous and docking sensor developed using a commercial off the shelf Android-based smartphone. It aims to provide a miniaturized solution for rendezvous and docking, enabling small satellites to conduct proximity operations and formation flying while minimizing interference with a primary payload. Previously, the sensor was limited by a slow (2 Hz) refresh rate and its use of retro-reflectors, both of which contributed to a limited operating environment. To advance the technology readiness level, a modified approach was developed, combining a multi-colored LED target with a focused target-detection algorithm. Alone, the use of an LED system was determined to be much more reliable, though slower, than the retro-reflector system. The focused target-detection system was developed in response to this problem to mitigate the speed reduction of using color. However it also improved the reliability. In combination these two methods have been demonstrated to dramatically increase sensor speed and allow the sensor to select the target even with significant noise interfering with the sensor, providing millimeter level precision at a range of two meters with a 1U target.

  17. Beta-Delayed Neutron Spectroscopy with Trapped Fission Products

    NASA Astrophysics Data System (ADS)

    Czeszumska, A.; Scielzo, N. D.; Norman, E. B.; Savard, G.; Aprahamian, A.; Burkey, M.; Caldwell, S. A.; Chiara, C. J.; Clark, J. A.; Harker, J.; Marley, S. T.; Morgan, G.; Orford, R.; Padgett, S.; Perez Galvan, A.; Segel, R. E.; Sharma, K. S.; Siegl, K.; Strauss, S.; Yee, R. M.

    2014-09-01

    Characterizing β-delayed neutron emission (βn) is of importance in reactor safety modeling, understanding of r-process nucleosynthesis, and nuclear structure studies. A newly developed technique enables a reliable measurement of βn branching ratios and neutron energy spectra without directly detecting neutrons. Ions of interest are loaded into a Paul trap surrounded by an array of radiation detectors. Upon decay, recoiling daughter nuclei and emitted particles emerge from the center of the trap with minimal scattering. The neutron energy is then determined from the time-of-flight, and hence momentum, of the recoiling ions. I will explain the details of the technique, and present the results from the most recent experimental campaign at the CARIBU facility at Argonne National Laboratory. Characterizing β-delayed neutron emission (βn) is of importance in reactor safety modeling, understanding of r-process nucleosynthesis, and nuclear structure studies. A newly developed technique enables a reliable measurement of βn branching ratios and neutron energy spectra without directly detecting neutrons. Ions of interest are loaded into a Paul trap surrounded by an array of radiation detectors. Upon decay, recoiling daughter nuclei and emitted particles emerge from the center of the trap with minimal scattering. The neutron energy is then determined from the time-of-flight, and hence momentum, of the recoiling ions. I will explain the details of the technique, and present the results from the most recent experimental campaign at the CARIBU facility at Argonne National Laboratory. This work was supported under contracts DE-NA0000979 (NSSC), DE-AC52-07NA27344 (LLNL), DE-AC02-06CH11357 (ANL), DE-FG02-94ER40834 (U. Maryland), DE-FG02-98ER41086 (Northwestern U.), NSERC, Canada, under Application No. 216974, and DHS.

  18. Establishing optimal quantitative-polymerase chain reaction assays for routine diagnosis and tracking of minimal residual disease in JAK2-V617F-associated myeloproliferative neoplasms: a joint European LeukemiaNet/MPN&MPNr-EuroNet (COST action BM0902) study.

    PubMed

    Jovanovic, J V; Ivey, A; Vannucchi, A M; Lippert, E; Oppliger Leibundgut, E; Cassinat, B; Pallisgaard, N; Maroc, N; Hermouet, S; Nickless, G; Guglielmelli, P; van der Reijden, B A; Jansen, J H; Alpermann, T; Schnittger, S; Bench, A; Tobal, K; Wilkins, B; Cuthill, K; McLornan, D; Yeoman, K; Akiki, S; Bryon, J; Jeffries, S; Jones, A; Percy, M J; Schwemmers, S; Gruender, A; Kelley, T W; Reading, S; Pancrazzi, A; McMullin, M F; Pahl, H L; Cross, N C P; Harrison, C N; Prchal, J T; Chomienne, C; Kiladjian, J J; Barbui, T; Grimwade, D

    2013-10-01

    Reliable detection of JAK2-V617F is critical for accurate diagnosis of myeloproliferative neoplasms (MPNs); in addition, sensitive mutation-specific assays can be applied to monitor disease response. However, there has been no consistent approach to JAK2-V617F detection, with assays varying markedly in performance, affecting clinical utility. Therefore, we established a network of 12 laboratories from seven countries to systematically evaluate nine different DNA-based quantitative PCR (qPCR) assays, including those in widespread clinical use. Seven quality control rounds involving over 21,500 qPCR reactions were undertaken using centrally distributed cell line dilutions and plasmid controls. The two best-performing assays were tested on normal blood samples (n=100) to evaluate assay specificity, followed by analysis of serial samples from 28 patients transplanted for JAK2-V617F-positive disease. The most sensitive assay, which performed consistently across a range of qPCR platforms, predicted outcome following transplant, with the mutant allele detected a median of 22 weeks (range 6-85 weeks) before relapse. Four of seven patients achieved molecular remission following donor lymphocyte infusion, indicative of a graft vs MPN effect. This study has established a robust, reliable assay for sensitive JAK2-V617F detection, suitable for assessing response in clinical trials, predicting outcome and guiding management of patients undergoing allogeneic transplant.

  19. Psychometric evaluation of the Swedish version of the pure procrastination scale, the irrational procrastination scale, and the susceptibility to temptation scale in a clinical population.

    PubMed

    Rozental, Alexander; Forsell, Erik; Svensson, Andreas; Forsström, David; Andersson, Gerhard; Carlbring, Per

    2014-01-01

    Procrastination is a prevalent self-regulatory failure associated with stress and anxiety, decreased well-being, and poorer performance in school as well as work. One-fifth of the adult population and half of the student population describe themselves as chronic and severe procrastinators. However, despite the fact that it can become a debilitating condition, valid and reliable self-report measures for assessing the occurrence and severity of procrastination are lacking, particularly for use in a clinical context. The current study explored the usefulness of the Swedish version of three Internet-administered self-report measures for evaluating procrastination; the Pure Procrastination Scale, the Irrational Procrastination Scale, and the Susceptibility to Temptation Scale, all having good psychometric properties in English. In total, 710 participants were recruited for a clinical trial of Internet-based cognitive behavior therapy for procrastination. All of the participants completed the scales as well as self-report measures of depression, anxiety, and quality of life. Principal Component Analysis was performed to assess the factor validity of the scales, and internal consistency and correlations between the scales were also determined. Intraclass Correlation Coefficient, Minimal Detectable Change, and Standard Error of Measurement were calculated for the Irrational Procrastination Scale. The Swedish version of the scales have a similar factor structure as the English version, generated good internal consistencies, with Cronbach's α ranging between .76 to .87, and were moderately to highly intercorrelated. The Irrational Procrastination Scale had an Intraclass Correlation Coefficient of .83, indicating excellent reliability. Furthermore, Standard Error of Measurement was 1.61, and Minimal Detectable Change was 4.47, suggesting that a change of almost five points on the scale is necessary to determine a reliable change in self-reported procrastination severity. The current study revealed that the Pure Procrastination Scale, the Irrational Procrastination Scale, and the Susceptibility to Temptation Scale are both valid and reliable from a psychometric perspective, and that they might be used for assessing the occurrence and severity of procrastination via the Internet. The current study is part of a clinical trial assessing the efficacy of Internet-based cognitive behavior therapy for procrastination, and was registered 04/22/2013 on ClinicalTrials.gov (NCT01842945).

  20. Associated-particle sealed-tube neutron probe for characterization of materials

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rhodes, E.; Dickerman, C.E.; Peters, C.W.

    1993-10-01

    A neutron diagnostic probe system has been developed that can identify and image most elements having a larger atomic number than boron. It can satisfy van-mobile and fixed-portal requirements for nondestructive detection of contraband drugs, explosives, and nuclear and chemical warfare weapon materials, and for treaty verification of sealed munitions and remediation of radioactive waste. The probe is based on a nonpulsed associated-particle sealed-tube neutron generator (APSTNG) that interrogates the object with a 14-MeV neutrons and detects alpha-particle associated with each neutron. Gamma-ray spectra of resulting neutron reactions (primarily inelastic scattering) identify nuclides associated with drugs, explosives, and other contraband.more » Flight times determined from detection times of gamma-rays and alpha-particles yield a separate coarse tomographic image of each identified nuclide. Chemical substances are identified and imaged by comparing relative spectra fine intensities with ratios of elements in reference compounds. The High-energy neutrons in gamma-rays will penetrate large objects and dense materials. The source and emission detection systems can be on the same side, allowing measurements with access to one side only. A high signal-to-background ratio is obtained and maximum information is extracted from each detected gamma-ray, yet high-bandwidth data acquisition is not required. The APSTNG also forms the basis for a compact fast-neutron transmission imaging system. No collimators are required, and only minimal shielding is needed. The small and relatively inexpensive neutron generator tube exhibits high reliability and can be quickly replaced. The detector arrays and associated electronics can be made reliable with low maintenance cost.« less

  1. Use of airborne and terrestrial lidar to detect ground displacement hazards to water systems

    USGS Publications Warehouse

    Stewart, J.P.; Hu, Jiawen; Kayen, R.E.; Lembo, A.J.; Collins, B.D.; Davis, C.A.; O'Rourke, T. D.

    2009-01-01

    We investigate the use of multiepoch airborne and terrestrial lidar to detect and measure ground displacements of sufficient magnitude to damage buried pipelines and other water system facilities that might result, for example, from earthquake or rainfall-induced landslides. Lidar scans are performed at three sites with coincident measurements by total station surveying. Relative horizontal accuracy is evaluated by measurements of lateral dimensions of well defined objects such as buildings and tanks; we find misfits ranging from approximately 5 to 12 cm, which is consistent with previous work. The bias and dispersion of lidar elevation measurements, relative to total station surveying, is assessed at two sites: (1) a power plant site (PP2) with vegetated steeply sloping terrain; and (2) a relatively flat and unvegetated site before and after trenching operations were performed. At PP2, airborne lidar showed minimal elevation bias and a standard deviation of approximately 70 cm, whereas terrestrial lidar did not produce useful results due to beam divergence issues and inadequate sampling of the study region. At the trench site, airborne lidar showed minimal elevation bias and reduced standard deviation relative to PP2 (6-20 cm), whereas terrestrial lidar was nearly unbiased with very low dispersion (4-6 cm). Pre- and posttrench bias-adjusted normalized residuals showed minimal to negligible correlation, but elevation change was affected by relative bias between epochs. The mean of elevation change bias essentially matches the difference in means of pre- and posttrench elevation bias, whereas elevation change standard deviation is sensitive to the dispersion of individual epoch elevations and their correlation coefficient. The observed lidar bias and standard deviations enable reliable detection of damaging ground displacements for some pipelines types (e.g., welded steel) but not all (e.g., concrete with unwelded, mortared joints). ?? ASCE 2009.

  2. Operation and force analysis of the guide wire in a minimally invasive vascular interventional surgery robot system

    NASA Astrophysics Data System (ADS)

    Yang, Xue; Wang, Hongbo; Sun, Li; Yu, Hongnian

    2015-03-01

    To develop a robot system for minimally invasive surgery is significant, however the existing minimally invasive surgery robots are not applicable in practical operations, due to their limited functioning and weaker perception. A novel wire feeder is proposed for minimally invasive vascular interventional surgery. It is used for assisting surgeons in delivering a guide wire, balloon and stenting into a specific lesion location. By contrasting those existing wire feeders, the motion methods for delivering and rotating the guide wire in blood vessel are described, and their mechanical realization is presented. A new resistant force detecting method is given in details. The change of the resistance force can help the operator feel the block or embolism existing in front of the guide wire. The driving torque for rotating the guide wire is developed at different positions. Using the CT reconstruction image and extracted vessel paths, the path equation of the blood vessel is obtained. Combining the shapes of the guide wire outside the blood vessel, the whole bending equation of the guide wire is obtained. That is a risk criterion in the delivering process. This process can make operations safer and man-machine interaction more reliable. A novel surgery robot for feeding guide wire is designed, and a risk criterion for the system is given.

  3. Automatic detection of snow avalanches in continuous seismic data using hidden Markov models

    NASA Astrophysics Data System (ADS)

    Heck, Matthias; Hammer, Conny; van Herwijnen, Alec; Schweizer, Jürg; Fäh, Donat

    2018-01-01

    Snow avalanches generate seismic signals as many other mass movements. Detection of avalanches by seismic monitoring is highly relevant to assess avalanche danger. In contrast to other seismic events, signals generated by avalanches do not have a characteristic first arrival nor is it possible to detect different wave phases. In addition, the moving source character of avalanches increases the intricacy of the signals. Although it is possible to visually detect seismic signals produced by avalanches, reliable automatic detection methods for all types of avalanches do not exist yet. We therefore evaluate whether hidden Markov models (HMMs) are suitable for the automatic detection of avalanches in continuous seismic data. We analyzed data recorded during the winter season 2010 by a seismic array deployed in an avalanche starting zone above Davos, Switzerland. We re-evaluated a reference catalogue containing 385 events by grouping the events in seven probability classes. Since most of the data consist of noise, we first applied a simple amplitude threshold to reduce the amount of data. As first classification results were unsatisfying, we analyzed the temporal behavior of the seismic signals for the whole data set and found that there is a high variability in the seismic signals. We therefore applied further post-processing steps to reduce the number of false alarms by defining a minimal duration for the detected event, implementing a voting-based approach and analyzing the coherence of the detected events. We obtained the best classification results for events detected by at least five sensors and with a minimal duration of 12 s. These processing steps allowed identifying two periods of high avalanche activity, suggesting that HMMs are suitable for the automatic detection of avalanches in seismic data. However, our results also showed that more sensitive sensors and more appropriate sensor locations are needed to improve the signal-to-noise ratio of the signals and therefore the classification.

  4. Reliability of Real-time Ultrasound Imaging for the Assessment of Trunk Stabilizer Muscles: A Systematic Review of the Literature.

    PubMed

    Taghipour, Morteza; Mohseni-Bandpei, Mohammad Ali; Behtash, Hamid; Abdollahi, Iraj; Rajabzadeh, Fatemeh; Pourahmadi, Mohammad Reza; Emami, Mahnaz

    2018-04-24

    Rehabilitative ultrasound (US) imaging is one of the popular methods for investigating muscle morphologic characteristics and dimensions in recent years. The reliability of this method has been investigated in different studies. As studies have been performed with different designs and quality, reported values of rehabilitative US have a wide range. The objective of this study was to systematically review the literature conducted on the reliability of rehabilitative US imaging for the assessment of deep abdominal and lumbar trunk muscle dimensions. The PubMed/MEDLINE, Scopus, Google Scholar, Science Direct, Embase, Physiotherapy Evidence, Ovid, and CINAHL databases were searched to identify original research articles conducted on the reliability of rehabilitative US imaging published from June 2007 to August 2017. The articles were qualitatively assessed; reliability data were extracted; and the methodological quality was evaluated by 2 independent reviewers. Of the 26 included studies, 16 were considered of high methodological quality. Except for 2 studies, all high-quality studies reported intraclass correlation coefficients (ICCs) for intra-rater reliability of 0.70 or greater. Also, ICCs reported for inter-rater reliability in high-quality studies were generally greater than 0.70. Among low-quality studies, reported ICCs ranged from 0.26 to 0.99 and 0.68 to 0.97 for intra- and inter-rater reliability, respectively. Also, the reported standard error of measurement and minimal detectable change for rehabilitative US were generally in an acceptable range. Generally, the results of the reviewed studies indicate that rehabilitative US imaging has good levels of both inter- and intra-rater reliability. © 2018 by the American Institute of Ultrasound in Medicine.

  5. Relative and absolute test-retest reliabilities of pressure pain threshold in patients with knee osteoarthritis.

    PubMed

    Srimurugan Pratheep, Neeraja; Madeleine, Pascal; Arendt-Nielsen, Lars

    2018-04-25

    Pressure pain threshold (PPT) and PPT maps are commonly used to quantify and visualize mechanical pain sensitivity. Although PPT's have frequently been reported from patients with knee osteoarthritis (KOA), the absolute and relative reliability of PPT assessments remain to be determined. Thus, the purpose of this study was to evaluate the test-retest relative and absolute reliability of PPT in KOA. For that purpose, intra- and interclass correlation coefficient (ICC) as well as the standard error of measurement (SEM) and the minimal detectable change (MDC) values within eight anatomical locations covering the most painful knee of KOA patients was measured. Twenty KOA patients participated in two sessions with a period of 2 weeks±3 days apart. PPT's were assessed over eight anatomical locations covering the knee and two remote locations over tibialis anterior and brachioradialis. The patients rated their maximum pain intensity during the past 24 h and prior to the recordings on a visual analog scale (VAS), and completed The Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) and PainDetect surveys. The ICC, SEM and MDC between the sessions were assessed. The ICC for the individual variability was expressed with coefficient of variance (CV). Bland-Altman plots were used to assess potential bias in the dataset. The ICC ranged from 0.85 to 0.96 for all the anatomical locations which is considered "almost perfect". CV was lowest in session 1 and ranged from 44.2 to 57.6%. SEM for comparison ranged between 34 and 71 kPa and MDC ranged between 93 and 197 kPa with a mean PPT ranged from 273.5 to 367.7 kPa in session 1 and 268.1-331.3 kPa in session 2. The analysis of Bland-Altman plot showed no systematic bias. PPT maps showed that the patients had lower thresholds in session 2, but no significant difference was observed for the comparison between the sessions for PPT or VAS. No correlations were seen between PainDetect and PPT and PainDetect and WOMAC. Almost perfect relative and absolute reliabilities were found for the assessment of PPT's for KOA patients. The present investigation implicates that PPT's is reliable for assessing pain sensitivity and sensitization in KOA patients.

  6. Fungal disease detection in plants: Traditional assays, novel diagnostic techniques and biosensors.

    PubMed

    Ray, Monalisa; Ray, Asit; Dash, Swagatika; Mishra, Abtar; Achary, K Gopinath; Nayak, Sanghamitra; Singh, Shikha

    2017-01-15

    Fungal diseases in commercially important plants results in a significant reduction in both quality and yield, often leading to the loss of an entire plant. In order to minimize the losses, it is essential to detect and identify the pathogens at an early stage. Early detection and accurate identification of pathogens can control the spread of infection. The present article provides a comprehensive overview of conventional methods, current trends and advances in fungal pathogen detection with an emphasis on biosensors. Traditional techniques are the "gold standard" in fungal detection which relies on symptoms, culture-based, morphological observation and biochemical identifications. In recent times, with the advancement of biotechnology, molecular and immunological approaches have revolutionized fungal disease detection. But the drawback lies in the fact that these methods require specific and expensive equipments. Thus, there is an urgent need for rapid, reliable, sensitive, cost effective and easy to use diagnostic methods for fungal pathogen detection. Biosensors would become a promising and attractive alternative, but they still have to be subjected to some modifications, improvements and proper validation for on-field use. Copyright © 2016 Elsevier B.V. All rights reserved.

  7. Inter-rater reliability of select physical examination procedures in patients with neck pain.

    PubMed

    Hanney, William J; George, Steven Z; Kolber, Morey J; Young, Ian; Salamh, Paul A; Cleland, Joshua A

    2014-07-01

    This study evaluated the inter-rater reliability of select examination procedures in patients with neck pain (NP) conducted over a 24- to 48-h period. Twenty-two patients with mechanical NP participated in a standardized examination. One examiner performed standardized examination procedures and a second blinded examiner repeated the procedures 24-48 h later with no treatment administered between examinations. Inter-rater reliability was calculated with the Cohen Kappa and weighted Kappa for ordinal data while continuous level data were calculated using an intraclass correlation coefficient model 2,1 (ICC2,1). Coefficients for categorical variables ranged from poor to moderate agreement (-0.22 to 0.70 Kappa) and coefficients for continuous data ranged from slight to moderate (ICC2,1 0.28-0.74). The standard error of measurement for cervical range of motion ranged from 5.3° to 9.9° while the minimal detectable change ranged from 12.5° to 23.1°. This study is the first to report inter-rater reliability values for select components of the cervical examination in those patients with NP performed 24-48 h after the initial examination. There was considerably less reliability when compared to previous studies, thus clinicians should consider how the passage of time may influence variability in examination findings over a 24- to 48-h period.

  8. Reliability and Accuracy of Static Parameters Obtained From Ink and Pressure Platform Footprints.

    PubMed

    Zuil-Escobar, Juan Carlos; Martínez-Cepa, Carmen Belén; Martín-Urrialde, Jose Antonio; Gómez-Conesa, Antonia

    2016-09-01

    The purpose of this study was to evaluate the accuracy and the intrarater reliability of arch angle (AA), Staheli Index (SI), and Chippaux-Smirak Index (CSI) obtained from ink and pressure platform footprints. We obtained AA, SI, and CSI measurements from ink pedigraph footprints and pressure platform footprints in 40 healthy participants (aged 25.65 ± 5.187 years). Intrarater reliability was calculated for all parameters obtained using the 2 methods. Standard error of measurement and minimal detectable change were also calculated. A repeated-measure analysis of variance was used to identify differences between ink and pressure platform footprints. Intraclass correlation coefficient and Bland and Altman plots were used to assess similar parameters obtained using different methods. Intrarater reliability was >0.9 for all parameters and was slightly higher for the ink footprints. No statistical difference was reported in repeated-measure analysis of variance for any of the parameters. Intraclass correlation coefficient values from AA, SI, and CSI that were obtained using ink footprints and pressure platform footprints were excellent, ranging from 0.797 to 0.829. However, pressure platform overestimated AA and underestimated SI and CSI. Our study revealed that AA, SI, and CSI were similar regardless of whether the ink or pressure platform method was used. In addition, the parameters indicated high intrarater reliability and were reproducible. Copyright © 2016. Published by Elsevier Inc.

  9. Reliability of different methodologies of infrared image analysis of myofascial trigger points in the upper trapezius muscle

    PubMed Central

    Dibai-Filho, Almir V.; Guirro, Elaine C. O.; Ferreira, Vânia T. K.; Brandino, Hugo E.; Vaz, Maíta M. O. L. L.; Guirro, Rinaldo R. J.

    2015-01-01

    BACKGROUND: Infrared thermography is recognized as a viable method for evaluation of subjects with myofascial pain. OBJECTIVE: The aim of the present study was to assess the intra- and inter-rater reliability of infrared image analysis of myofascial trigger points in the upper trapezius muscle. METHOD: A reliability study was conducted with 24 volunteers of both genders (23 females) between 18 and 30 years of age (22.12±2.54), all having cervical pain and presence of active myofascial trigger point in the upper trapezius muscle. Two trained examiners performed analysis of point, line, and area of the infrared images at two different periods with a 1-week interval. The intra-class correlation coefficient (ICC2,1) was used to assess the intra- and inter-rater reliability. RESULTS: With regard to the intra-rater reliability, ICC values were between 0.591 and 0.993, with temperatures between 0.13 and 1.57 °C for values of standard error of measurement (SEM) and between 0.36 and 4.35 °C for the minimal detectable change (MDC). For the inter-rater reliability, ICC ranged from 0.615 to 0.918, with temperatures between 0.43 and 1.22 °C for the SEM and between 1.19 and 3.38 °C for the MDC. CONCLUSION: The methods of infrared image analyses of myofascial trigger points in the upper trapezius muscle employed in the present study are suitable for clinical and research practices. PMID:25993626

  10. Responsiveness, minimal detectable change, and minimal clinically important difference of the Nottingham Extended Activities of Daily Living Scale in patients with improved performance after stroke rehabilitation.

    PubMed

    Wu, Ching-yi; Chuang, Li-ling; Lin, Keh-chung; Lee, Shin-da; Hong, Wei-hsien

    2011-08-01

    To determine the responsiveness, minimal detectable change (MDC), and minimal clinically important differences (MCIDs) of the Nottingham Extended Activities of Daily Living (NEADL) scale and to assess percentages of patients' change scores exceeding the MDC and MCID after stroke rehabilitation. Secondary analyses of patients who received stroke rehabilitation therapy. Medical centers. Patients with stroke (N=78). Secondary analyses of patients who received 1 of 4 rehabilitation interventions. Responsiveness (standardized response mean [SRM]), 90% confidence that a change score at this threshold or higher is true and reliable rather than measurement error (MDC(90)), and MCID on the NEADL score and percentages of patients exceeding the MDC(90) and MCID. The SRM of the total NEADL scale was 1.3. The MDC(90) value for the total NEADL scale was 4.9, whereas minima and maxima of the MCID for total NEADL score were 2.4 and 6.1 points, respectively. Percentages of patients exceeding the MDC(90) and MCID of the total NEADL score were 50.0%, 73.1%, and 32.1%, respectively. The NEADL is a responsive instrument relevant for measuring change in instrumental activities of daily living after stroke rehabilitation. A patient's change score has to reach 4.9 points on the total to indicate a true change. The mean change score of a stroke group on the total NEADL scale should achieve 6.1 points to be regarded as clinically important. Our findings are based on patients with improved NEADL performance after they received specific interventions. Future research with larger sample sizes is warranted to validate these estimates. Copyright © 2011 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  11. Testing the effectiveness of automated acoustic sensors for monitoring vocal activity of Marbled Murrelets Brachyramphus marmoratus

    USGS Publications Warehouse

    Cragg, Jenna L.; Burger, Alan E.; Piatt, John F.

    2015-01-01

    Cryptic nest sites and secretive breeding behavior make population estimates and monitoring of Marbled Murrelets Brachyramphus marmoratus difficult and expensive. Standard audio-visual and radar protocols have been refined but require intensive field time by trained personnel. We examined the detection range of automated sound recorders (Song Meters; Wildlife Acoustics Inc.) and the reliability of automated recognition models (“recognizers”) for identifying and quantifying Marbled Murrelet vocalizations during the 2011 and 2012 breeding seasons at Kodiak Island, Alaska. The detection range of murrelet calls by Song Meters was estimated to be 60 m. Recognizers detected 20 632 murrelet calls (keer and keheer) from a sample of 268 h of recordings, yielding 5 870 call series, which compared favorably with human scanning of spectrograms (on average detecting 95% of the number of call series identified by a human observer, but not necessarily the same call series). The false-negative rate (percentage of murrelet call series that the recognizers failed to detect) was 32%, mainly involving weak calls and short call series. False-positives (other sounds included by recognizers as murrelet calls) were primarily due to complex songs of other bird species, wind and rain. False-positives were lower in forest nesting habitat (48%) and highest in shrubby vegetation where calls of other birds were common (97%–99%). Acoustic recorders tracked spatial and seasonal trends in vocal activity, with higher call detections in high-quality forested habitat and during late July/early August. Automated acoustic monitoring of Marbled Murrelet calls could provide cost-effective, valuable information for assessing habitat use and temporal and spatial trends in nesting activity; reliability is dependent on careful placement of sensors to minimize false-positives and on prudent application of digital recognizers with visual checking of spectrograms.

  12. Assessment of need for transport tubes when continuously monitoring for radioactive aerosols.

    PubMed

    Whicker, J J; Rodgers, J C; Lopez, R C

    1999-09-01

    Aerosol transport tubes are often used to draw aerosol from desirable sampling locations to nearby air sampling equipment that cannot be placed at that location. In many plutonium laboratories at Los Alamos National Laboratory, aerosol transport tubes are used to transport aerosol from the front of room ventilation exhaust registers to continuous air monitors (CAMs) that are mounted on nearby walls. Transport tubes are used because past guidance suggests that extraction of aerosol samples from exhaust locations provides the most sensitive and reliable detection under conditions where the rooms have unpredictable release locations and significant spatial variability in aerosol concentrations after releases, and where CAMs cannot be located in front of exhaust registers without blocking worker walkways. Despite designs to minimize particle loss in tubes, aerosol transport model predictions suggest losses occur lowering the sensitivity of CAMs to accidentally released plutonium aerosol. The goal of this study was to test the hypotheses that the reliability, speed, and sensitivity of aerosol detection would be equal whether the sample was extracted from the front of the exhaust register or from the wall location of CAMs. Polydisperse oil aerosols were released from multiple locations in two plutonium laboratories to simulate plutonium aerosol releases. Networked laser particle counters (LPCs) were positioned to simultaneously measure time-resolved aerosol concentrations at each exhaust register (representative of sampling with transport tubes) and at each wall-mounted CAM location (representative of sampling without transport tubes). Results showed no significant differences in detection reliability, speed, or sensitivity for LPCs positioned at exhaust locations when compared to LPCs positioned at the CAM wall location. Therefore, elimination of transport tubes would likely improve CAM performance.

  13. Intra-rater reliability of hallux flexor strength measures using the Nintendo Wii Balance Board.

    PubMed

    Quek, June; Treleaven, Julia; Brauer, Sandra G; O'Leary, Shaun; Clark, Ross A

    2015-01-01

    The purpose of this study was to investigate the intra-rater reliability of a new method in combination with the Nintendo Wii Balance Board (NWBB) to measure the strength of hallux flexor muscle. Thirty healthy individuals (age: 34.9 ± 12.9 years, height: 170.4 ± 10.5 cm, weight: 69.3 ± 15.3 kg, female = 15) participated. Repeated testing was completed within 7 days. Participants performed strength testing in sitting using a wooden platform in combination with the NWBB. This new method was set up to selectively recruit an intrinsic muscle of the foot, specifically the flexor hallucis brevis muscle. Statistical analysis was performed using intra-class coefficients and ordinary least product analysis. To estimate measurement error, standard error of measurement (SEM), minimal detectable change (MDC) and percentage error were calculated. Results indicate excellent intra-rater reliability (ICC = 0.982, CI = 0.96-0.99) with an absence of systematic bias. SEM, MDC and percentage error value were 0.5, 1.4 and 12 % respectively. This study demonstrates that a new method in combination with the NWBB application is reliable to measure hallux flexor strength and has potential to be used for future research and clinical application.

  14. Comparison of three techniques for evaluating skin erythemal response for determination of sun protection factors of sunscreens: high resolution laser Doppler imaging, colorimetry and visual scoring.

    PubMed

    Wilhelm, K P; Kaspar, K; Funkel, O

    2001-04-01

    Sun protection factor (SPF) measurement is based on the determination of the minimal erythema dose (MED). The ratio of doses required to induce a minimal erythema between product-treated and untreated skin is defined as SPF. The aim of this study was to validate the conventionally used visual scoring with two non-invasive methods: high resolution laser Doppler imaging (HR-LDI) and colorimetry. Another goal was to check whether suberythemal reactions could be detected by means of HR-LDI measurements. Four sunscreens were selected. The measurements were made on the back of 10 subjects. A solar simulator SU 5000 (m.u.t., Wedel, Germany) served as radiation source. For the visual assessment, the erythema was defined according to COLIPA as the first perceptible, clearly defined unambiguous redness of the skin. For the colorimetric determination of the erythema, a Chromameter CR 300 (Minolta, Osaka, Japan) was used. The threshold for the colorimetry was chosen according to the COLIPA recommendation as an increase of the redness parameter delta a* = 2.5. For the non-contact perfusion measurements of skin blood flow, a two-dimensional high resolution laser Doppler imager (HR-LDI) (Lisca, Linköping, Sweden) was used. For the HR-LDI measurements, an optimal threshold perfusion needed to be established. For the HR-LDI measurements basal perfusion +1 standard deviation of all basal measurements was found to be a reliable threshold perfusion corresponding to the minimal erythema. Smaller thresholds, which would be necessary for detection of suberythemal responses, did not provide unambiguous data. All three methods, visual scoring, colorimetry and HR-LDI, produced similar SPFs for the test products with a variability of < 5% between methods. The HR-LDI method showed the lowest variation of the mean SPF. Neither of the instrumental methods, however, resulted in an increase of the sensitivity of SPF determination as compared with visual scoring. Both HR-LDI and colorimetry are suitable, reliable and observer-independent methods for MED determination. However, they do not provide greater sensitivity and thus do not result in lower UV dose requirements for testing.

  15. Photonics

    NASA Astrophysics Data System (ADS)

    Roh, Won B.

    Photonic technologies-based computational systems are projected to be able to offer order-of-magnitude improvements in processing speed, due to their intrinsic architectural parallelism and ultrahigh switching speeds; these architectures also minimize connectors, thereby enhancing reliability, and preclude EMP vulnerability. The use of optoelectronic ICs would also extend weapons capabilities in such areas as automated target recognition, systems-state monitoring, and detection avoidance. Fiber-optics technologies have an information-carrying capacity fully five orders of magnitude greater than copper-wire-based systems; energy loss in transmission is two orders of magnitude lower, and error rates one order of magnitude lower. Attention is being given to ZrF glasses for optical fibers with unprecedentedly low scattering levels.

  16. Coal/rock interface detection by sensitized pick, part A

    NASA Technical Reports Server (NTRS)

    Wu, P. T. K.; Erkes, J. W.

    1981-01-01

    In order to increase the operating margins of the detector for safe, reliable operation under difficult in-mine conditions the transmitted signal strength was increased to provide additional signal margin for in-mine conditions and the transmitter section was redesigned to reduce frequency pulling of the transmitter frequency with variations in antenna load. The linearity of the pick load SCO signal with true pick load was increased, and hysteresis effects were minimized. The sensitized pick hardware was ruggedized for rough inmine use. The sensitized pick and telemetry system provided excellent, high quality signals proportional to cutting load under all conditions experienced during testing.

  17. Improved HgCdTe detectors with novel antireflection coating

    NASA Astrophysics Data System (ADS)

    Babu, Sachi R.; Hu, Kelley; Manthripragada, Sridhar; Martineau, Robert J.; Kotecki, C. A.; Peters, F. A.; Burgess, A. S.; Krebs, Danny J.; Mott, David B.; Ewin, Audrey J.; Miles, A.; Nguyen, Trang L.; Shu, Peter K.

    1996-10-01

    The composite infrared spctrometer (CIRS) is an important instrument for the upcoming Cassini mission for sensing infrared (IR) radiation from the Saturanian planetary system. We have delivered a linear, ten element, mercury cadmium telluride (HgCdTe) photoconductive detector array for use on focal plane 3 (FP3), which is responsible for detecting radiation from the 9.1 micrometer to 16.6 micrometer wavelength range. Reliable HgCdTe detectors require robust passivation, a low-stress zinc sulfide (ZnS) anti-reflection (AR) coating with good adhesion, and a proper optical cavity design to smooth out the resonance in the detector spectral response. During the development of CIRS flight array, we have demonstrated the potential of using an in-situ interfacial layer, such as SiN(subscript x), between ZnS and the anodic oxide. Such an interfacial layer drastically improves the adhesion between the ZnS and oxide, without degrading the minority carrier lifetime. We have also demonstrated the feasibility of applying a SiN(subscript x) 'rain coat' layer over the ZnS to prevent moisture and other chemicals from attacking the AR coating, thus improving the long term reliability. This also enables device operation in a hazardous environment. The alumina/epoxy/HgCdTe/oxide/ZnS structure is a complicated multi-cavity optical system. We have developed an extensive device simulation, which enables us to make the optimal choice of individual cavity thickness for minimizing the resonance and maximizing the quantum efficiency. We have also used 0.05 micrometer alumina powder loaded epoxy to minimize the reflections at the epoxy/HgCdTe interface, thus minimizing the resonance.

  18. Measurement Properties of the Lower Extremity Functional Scale: A Systematic Review.

    PubMed

    Mehta, Saurabh P; Fulton, Allison; Quach, Cedric; Thistle, Megan; Toledo, Cesar; Evans, Neil A

    2016-03-01

    Systematic review of measurement properties. Many primary studies have examined the measurement properties, such as reliability, validity, and sensitivity to change, of the Lower Extremity Functional Scale (LEFS) in different clinical populations. A systematic review summarizing these properties for the LEFS may provide an important resource. To locate and synthesize evidence on the measurement properties of the LEFS and to discuss the clinical implications of the evidence. A literature search was conducted in 4 databases (PubMed, MEDLINE, Embase, and CINAHL), using predefined search terms. Two reviewers performed a critical appraisal of the included studies using a standardized assessment form. A total of 27 studies were included in the review, of which 18 achieved a very good to excellent methodological quality level. The LEFS scores demonstrated excellent test-retest reliability (intraclass correlation coefficients ranging between 0.85 and 0.99) and demonstrated the expected relationships with measures assessing similar constructs (Pearson correlation coefficient values of greater than 0.7). The responsiveness of the LEFS scores was excellent, as suggested by consistently high effect sizes (greater than 0.8) in patients with different lower extremity conditions. Minimal detectable change at the 90% confidence level (MDC90) for the LEFS scores varied between 8.1 and 15.3 across different reassessment intervals in a wide range of patient populations. The pooled estimate of the MDC90 was 6 points and the minimal clinically important difference was 9 points in patients with lower extremity musculoskeletal conditions, which are indicative of true change and clinically meaningful change, respectively. The results of this review support the reliability, validity, and responsiveness of the LEFS scores for assessing functional impairment in a wide array of patient groups with lower extremity musculoskeletal conditions.

  19. Bio-ALIRT biosurveillance detection algorithm evaluation.

    PubMed

    Siegrist, David; Pavlin, J

    2004-09-24

    Early detection of disease outbreaks by a medical biosurveillance system relies on two major components: 1) the contribution of early and reliable data sources and 2) the sensitivity, specificity, and timeliness of biosurveillance detection algorithms. This paper describes an effort to assess leading detection algorithms by arranging a common challenge problem and providing a common data set. The objectives of this study were to determine whether automated detection algorithms can reliably and quickly identify the onset of natural disease outbreaks that are surrogates for possible terrorist pathogen releases, and do so at acceptable false-alert rates (e.g., once every 2-6 weeks). Historic de-identified data were obtained from five metropolitan areas over 23 months; these data included International Classification of Diseases, Ninth Revision (ICD-9) codes related to respiratory and gastrointestinal illness syndromes. An outbreak detection group identified and labeled two natural disease outbreaks in these data and provided them to analysts for training of detection algorithms. All outbreaks in the remaining test data were identified but not revealed to the detection groups until after their analyses. The algorithms established a probability of outbreak for each day's counts. The probability of outbreak was assessed as an "actual" alert for different false-alert rates. The best algorithms were able to detect all of the outbreaks at false-alert rates of one every 2-6 weeks. They were often able to detect for the same day human investigators had identified as the true start of the outbreak. Because minimal data exists for an actual biologic attack, determining how quickly an algorithm might detect such an attack is difficult. However, application of these algorithms in combination with other data-analysis methods to historic outbreak data indicates that biosurveillance techniques for analyzing syndrome counts can rapidly detect seasonal respiratory and gastrointestinal illness outbreaks. Further research is needed to assess the value of electronic data sources for predictive detection. In addition, simulations need to be developed and implemented to better characterize the size and type of biologic attack that can be detected by current methods by challenging them under different projected operational conditions.

  20. Combining contour detection algorithms for the automatic extraction of the preparation line from a dental 3D measurement

    NASA Astrophysics Data System (ADS)

    Ahlers, Volker; Weigl, Paul; Schachtzabel, Hartmut

    2005-04-01

    Due to the increasing demand for high-quality ceramic crowns and bridges, the CAD/CAM-based production of dental restorations has been a subject of intensive research during the last fifteen years. A prerequisite for the efficient processing of the 3D measurement of prepared teeth with a minimal amount of user interaction is the automatic determination of the preparation line, which defines the sealing margin between the restoration and the prepared tooth. Current dental CAD/CAM systems mostly require the interactive definition of the preparation line by the user, at least by means of giving a number of start points. Previous approaches to the automatic extraction of the preparation line rely on single contour detection algorithms. In contrast, we use a combination of different contour detection algorithms to find several independent potential preparation lines from a height profile of the measured data. The different algorithms (gradient-based, contour-based, and region-based) show their strengths and weaknesses in different clinical situations. A classifier consisting of three stages (range check, decision tree, support vector machine), which is trained by human experts with real-world data, finally decides which is the correct preparation line. In a test with 101 clinical preparations, a success rate of 92.0% has been achieved. Thus the combination of different contour detection algorithms yields a reliable method for the automatic extraction of the preparation line, which enables the setup of a turn-key dental CAD/CAM process chain with a minimal amount of interactive screen work.

  1. Multi-resolution Gabor wavelet feature extraction for needle detection in 3D ultrasound

    NASA Astrophysics Data System (ADS)

    Pourtaherian, Arash; Zinger, Svitlana; Mihajlovic, Nenad; de With, Peter H. N.; Huang, Jinfeng; Ng, Gary C.; Korsten, Hendrikus H. M.

    2015-12-01

    Ultrasound imaging is employed for needle guidance in various minimally invasive procedures such as biopsy guidance, regional anesthesia and brachytherapy. Unfortunately, a needle guidance using 2D ultrasound is very challenging, due to a poor needle visibility and a limited field of view. Nowadays, 3D ultrasound systems are available and more widely used. Consequently, with an appropriate 3D image-based needle detection technique, needle guidance and interventions may significantly be improved and simplified. In this paper, we present a multi-resolution Gabor transformation for an automated and reliable extraction of the needle-like structures in a 3D ultrasound volume. We study and identify the best combination of the Gabor wavelet frequencies. High precision in detecting the needle voxels leads to a robust and accurate localization of the needle for the intervention support. Evaluation in several ex-vivo cases shows that the multi-resolution analysis significantly improves the precision of the needle voxel detection from 0.23 to 0.32 at a high recall rate of 0.75 (gain 40%), where a better robustness and confidence were confirmed in the practical experiments.

  2. Standoff detection of explosives and chemical agents using broadly tuned external-cavity quantum cascade lasers (EC-QCLs)

    NASA Astrophysics Data System (ADS)

    Takeuchi, Eric B.; Rayner, Timothy; Weida, Miles; Crivello, Salvatore; Day, Timothy

    2007-10-01

    Civilian soft targets such as transportation systems are being targeted by terrorists using IEDs and suicide bombers. Having the capability to remotely detect explosives, precursors and other chemicals would enable these assets to be protected with minimal interruption of the flow of commerce. Mid-IR laser technology offers the potential to detect explosives and other chemicals in real-time and from a safe standoff distance. While many of these agents possess "fingerprint" signatures in the mid-IR (i.e. in the 3-20 micron regime), their effective interrogation by a practical, field-deployable system has been limited by size, complexity, reliability and cost constraints of the base laser technology. Daylight Solutions has addressed these shortcomings by developing compact, portable, broadly tunable mid-IR laser sources based upon external-cavity quantum cascade technology. This technology is now being applied by Daylight in system level architectures for standoff and remote detection of explosives, precursors and chemical agents. Several of these architectures and predicted levels of performance will be presented.

  3. Adaptive local thresholding for robust nucleus segmentation utilizing shape priors

    NASA Astrophysics Data System (ADS)

    Wang, Xiuzhong; Srinivas, Chukka

    2016-03-01

    This paper describes a novel local thresholding method for foreground detection. First, a Canny edge detection method is used for initial edge detection. Then, tensor voting is applied on the initial edge pixels, using a nonsymmetric tensor field tailored to encode prior information about nucleus size, shape, and intensity spatial distribution. Tensor analysis is then performed to generate the saliency image and, based on that, the refined edge. Next, the image domain is divided into blocks. In each block, at least one foreground and one background pixel are sampled for each refined edge pixel. The saliency weighted foreground histogram and background histogram are then created. These two histograms are used to calculate a threshold by minimizing the background and foreground pixel classification error. The block-wise thresholds are then used to generate the threshold for each pixel via interpolation. Finally, the foreground is obtained by comparing the original image with the threshold image. The effective use of prior information, combined with robust techniques, results in far more reliable foreground detection, which leads to robust nucleus segmentation.

  4. Test-Retest Reliability and Predictive Validity of the Implicit Association Test in Children

    ERIC Educational Resources Information Center

    Rae, James R.; Olson, Kristina R.

    2018-01-01

    The Implicit Association Test (IAT) is increasingly used in developmental research despite minimal evidence of whether children's IAT scores are reliable across time or predictive of behavior. When test-retest reliability and predictive validity have been assessed, the results have been mixed, and because these studies have differed on many…

  5. Development of a rapid, sensitive TaqMan real-time RT-PCR assay for the detection of Rose rosette virus using multiple gene targets.

    PubMed

    Babu, Binoy; Jeyaprakash, Ayyamperumal; Jones, Debra; Schubert, Timothy S; Baker, Carlye; Washburn, Brian K; Miller, Steven H; Poduch, Kristina; Knox, Gary W; Ochoa-Corona, Francisco M; Paret, Mathews L

    2016-09-01

    Rose rosette virus (RRV), belonging to the genus Emaravirus, is a highly destructive pathogen that causes rose rosette disease. The disease is a major concern for the rose industry in the U.S. due to the lack of highly sensitive methods for early detection of RRV. This is critical, as early identification of the infected plants and eradication is necessary in minimizing the risks associated with the spread of the disease. A highly reliable, specific and sensitive detection assay is thus required to test and confirm the presence of RRV in suspected plant samples. In this study a TaqMan real-time reverse transcription-polymerase chain reaction (RT-PCR) assay was developed for the detection of RRV from infected roses, utilizing multiple gene targets. Four pairs of primers and probes; two of them (RRV_2-1 and RRV_2-2) based on the consensus sequences of the glycoprotein gene (RNA2) and the other two (RRV_3-2 and RRV_3-5) based on the nucleocapsid gene (RNA3) were designed. The specificity of the primers and probes was evaluated against other representative viruses infecting roses, belonging to the genera Alfamovirus, Cucumovirus, Ilarvirus, Nepovirus, Tobamovirus, and Tospovirus and one Emaravirus (Wheat mosaic virus). Dilution assays using the in vitro transcripts (spiked with total RNA from healthy plants, and non-spiked) showed that all the primers and probes are highly sensitive in consistently detecting RRV with a detection limit of 1 fg. Testing of the infected plants over a period of time (three times in monthly intervals) indicated high reproducibility, with the primer/probe RRV_3-5 showing 100% positive detection, while RRV_2-1, RRV_2-2 and RRV_3-2 showed 90% positive detection. The developed real-time RT-PCR assay is reliable, highly sensitive, and can be easily used in diagnostic laboratories for testing and confirmation of RRV. Copyright © 2016 Elsevier B.V. All rights reserved.

  6. Assessing the stroke-specific quality of life for outcome measurement in stroke rehabilitation: minimal detectable change and clinically important difference.

    PubMed

    Lin, Keh-chung; Fu, Tiffany; Wu, Ching-yi; Hsieh, Ching-ju

    2011-01-19

    This study was conducted to establish the minimal detectable change (MDC) and clinically important differences (CIDs) of the physical category of the Stroke-Specific Quality of Life Scale in patients with stroke. MDC and CIDs scores were calculated from the data of 74 participants enrolled in randomized controlled trials investigating the effects of two rehabilitation programs in patients with stroke. These participants received treatments for 3 weeks and underwent clinical assessment before and after treatment. To obtain test-retest reliability for calculating MDC, another 25 patients with chronic stroke were recruited. The MDC was calculated from the standard error of measurement (SEM) to indicate a real change with 95% confidence for individual patients (MDC95). Distribution-based and anchor-based methods were adopted to triangulate the ranges of minimal CIDs. The percentage of scale width was calculated by dividing the MDC and CIDs by the total score range of each physical category. The percentage of patients exceeding MDC95 and minimal CIDs was also reported. The MDC95 of the mobility, self-care, and upper extremity (UE) function subscales were 5.9, 4.0, and 5.3 respectively. The minimal CID ranges for these 3 subscales were 1.5 to 2.4, 1.2 to 1.9, and 1.2 to 1.8. The percentage of patients exceeding MDC95 and minimal CIDs of the mobility, self-care, and UE function subscales were 9.5% to 28.4%, 6.8% to 28.4%, and 12.2% to 33.8%, respectively. The change score of an individual patient has to reach 5.9, 4.0, and 5.3 on the 3 subscales to indicate a true change. The mean change scores of a group of patients with stroke on these subscales should reach the lower bound of CID ranges of 1.5 (6.3% scale width), 1.2 (6.0% scale width), and 1.2 (6.0% scale width) to be regarded as clinically important change. This information may facilitate interpretations of patient-reported outcomes after stroke rehabilitation. Future research is warranted to validate these findings.

  7. Assessing the Stroke-Specific Quality of Life for Outcome Measurement in Stroke Rehabilitation: Minimal Detectable Change and Clinically Important Difference

    PubMed Central

    2011-01-01

    Background This study was conducted to establish the minimal detectable change (MDC) and clinically important differences (CIDs) of the physical category of the Stroke-Specific Quality of Life Scale in patients with stroke. Methods MDC and CIDs scores were calculated from the data of 74 participants enrolled in randomized controlled trials investigating the effects of two rehabilitation programs in patients with stroke. These participants received treatments for 3 weeks and underwent clinical assessment before and after treatment. To obtain test-retest reliability for calculating MDC, another 25 patients with chronic stroke were recruited. The MDC was calculated from the standard error of measurement (SEM) to indicate a real change with 95% confidence for individual patients (MDC95). Distribution-based and anchor-based methods were adopted to triangulate the ranges of minimal CIDs. The percentage of scale width was calculated by dividing the MDC and CIDs by the total score range of each physical category. The percentage of patients exceeding MDC95 and minimal CIDs was also reported. Results The MDC95 of the mobility, self-care, and upper extremity (UE) function subscales were 5.9, 4.0, and 5.3 respectively. The minimal CID ranges for these 3 subscales were 1.5 to 2.4, 1.2 to 1.9, and 1.2 to 1.8. The percentage of patients exceeding MDC95 and minimal CIDs of the mobility, self-care, and UE function subscales were 9.5% to 28.4%, 6.8% to 28.4%, and 12.2% to 33.8%, respectively. Conclusions The change score of an individual patient has to reach 5.9, 4.0, and 5.3 on the 3 subscales to indicate a true change. The mean change scores of a group of patients with stroke on these subscales should reach the lower bound of CID ranges of 1.5 (6.3% scale width), 1.2 (6.0% scale width), and 1.2 (6.0% scale width) to be regarded as clinically important change. This information may facilitate interpretations of patient-reported outcomes after stroke rehabilitation. Future research is warranted to validate these findings. PMID:21247433

  8. Scaling Impacts in Life Support Architecture and Technology Selection

    NASA Technical Reports Server (NTRS)

    Lange, Kevin

    2016-01-01

    For long-duration space missions outside of Earth orbit, reliability considerations will drive higher levels of redundancy and/or on-board spares for life support equipment. Component scaling will be a critical element in minimizing overall launch mass while maintaining an acceptable level of system reliability. Building on an earlier reliability study (AIAA 2012-3491), this paper considers the impact of alternative scaling approaches, including the design of technology assemblies and their individual components to maximum, nominal, survival, or other fractional requirements. The optimal level of life support system closure is evaluated for deep-space missions of varying duration using equivalent system mass (ESM) as the comparative basis. Reliability impacts are included in ESM by estimating the number of component spares required to meet a target system reliability. Common cause failures are included in the analysis. ISS and ISS-derived life support technologies are considered along with selected alternatives. This study focusses on minimizing launch mass, which may be enabling for deep-space missions.

  9. Assessment of spare reliability for multi-state computer networks within tolerable packet unreliability

    NASA Astrophysics Data System (ADS)

    Lin, Yi-Kuei; Huang, Cheng-Fu

    2015-04-01

    From a quality of service viewpoint, the transmission packet unreliability and transmission time are both critical performance indicators in a computer system when assessing the Internet quality for supervisors and customers. A computer system is usually modelled as a network topology where each branch denotes a transmission medium and each vertex represents a station of servers. Almost every branch has multiple capacities/states due to failure, partial failure, maintenance, etc. This type of network is known as a multi-state computer network (MSCN). This paper proposes an efficient algorithm that computes the system reliability, i.e., the probability that a specified amount of data can be sent through k (k ≥ 2) disjoint minimal paths within both the tolerable packet unreliability and time threshold. Furthermore, two routing schemes are established in advance to indicate the main and spare minimal paths to increase the system reliability (referred to as spare reliability). Thus, the spare reliability can be readily computed according to the routing scheme.

  10. Optimization of Adaptive Intraply Hybrid Fiber Composites with Reliability Considerations

    NASA Technical Reports Server (NTRS)

    Shiao, Michael C.; Chamis, Christos C.

    1994-01-01

    The reliability with bounded distribution parameters (mean, standard deviation) was maximized and the reliability-based cost was minimized for adaptive intra-ply hybrid fiber composites by using a probabilistic method. The probabilistic method accounts for all naturally occurring uncertainties including those in constituent material properties, fabrication variables, structure geometry, and control-related parameters. Probabilistic sensitivity factors were computed and used in the optimization procedures. For actuated change in the angle of attack of an airfoil-like composite shell structure with an adaptive torque plate, the reliability was maximized to 0.9999 probability, with constraints on the mean and standard deviation of the actuation material volume ratio (percentage of actuation composite material in a ply) and the actuation strain coefficient. The reliability-based cost was minimized for an airfoil-like composite shell structure with an adaptive skin and a mean actuation material volume ratio as the design parameter. At a O.9-mean actuation material volume ratio, the minimum cost was obtained.

  11. Aggressive periodontitis: case definition and diagnostic criteria.

    PubMed

    Albandar, Jasim M

    2014-06-01

    Aggressive periodontitis is a destructive disease characterized by the following: the involvement of multiple teeth with a distinctive pattern of periodontal tissue loss; a high rate of disease progression; an early age of onset; and the absence of systemic diseases. In some patients periodontal tissue loss may commence before puberty, whereas in most patients the age of onset is during or somewhat after the circumpubertal period. Besides infection with specific microorganisms, a host predisposition seems to play a key role in the pathogenesis of aggressive periodontitis, as evidenced by the familial aggregation of the disease. In this article we review the historical background of the diagnostic criteria of aggressive periodontitis, present a contemporary case definition and describe the clinical parameters of the disease. At present, the diagnosis of aggressive periodontitis is achieved using case history, clinical examination and radiographic evaluation. The data gathered using these methods are prone to relatively high measurement errors. Besides, this diagnostic approach measures past disease history and may not reliably measure existing disease activity or accurately predict future tissue loss. A diagnosis is often made years after the onset of the disease, partly because current assessment methods detect established disease more readily and reliably than they detect incipient or initial lesions where the tissue loss is minimal and usually below the detection threshold of present examination methods. Future advancements in understanding the pathogenesis of this disease may contribute to an earlier diagnosis. Insofar, future case definitions may involve the identification of key etiologic and risk factors, combined with high-precision methodologies that enable the early detection of initial lesions. This may significantly enhance the predictive value of these tests and detect cases of aggressive periodontitis before significant tissue loss develops. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  12. Development of a qualitative, multiplex real-time PCR kit for screening of genetically modified organisms (GMOs).

    PubMed

    Dörries, Hans-Henno; Remus, Ivonne; Grönewald, Astrid; Grönewald, Cordt; Berghof-Jäger, Kornelia

    2010-03-01

    The number of commercially available genetically modified organisms (GMOs) and therefore the diversity of possible target sequences for molecular detection techniques are constantly increasing. As a result, GMO laboratories and the food production industry currently are forced to apply many different methods to reliably test raw material and complex processed food products. Screening methods have become more and more relevant to minimize the analytical effort and to make a preselection for further analysis (e.g., specific identification or quantification of the GMO). A multiplex real-time PCR kit was developed to detect the 35S promoter of the cauliflower mosaic virus, the terminator of the nopaline synthase gene of Agrobacterium tumefaciens, the 35S promoter from the figwort mosaic virus, and the bar gene of the soil bacterium Streptomyces hygroscopicus as the most widely used sequences in GMOs. The kit contains a second assay for the detection of plant-derived DNA to control the quality of the often processed and refined sample material. Additionally, the plant-specific assay comprises a homologous internal amplification control for inhibition control. The determined limits of detection for the five assays were 10 target copies/reaction. No amplification products were observed with DNAs of 26 bacterial species, 25 yeasts, 13 molds, and 41 not genetically modified plants. The specificity of the assays was further demonstrated to be 100% by the specific amplification of DNA derived from reference material from 22 genetically modified crops. The applicability of the kit in routine laboratory use was verified by testing of 50 spiked and unspiked food products. The herein described kit represents a simple and sensitive GMO screening method for the reliable detection of multiple GMO-specific target sequences in a multiplex real-time PCR reaction.

  13. A Delay-Aware and Reliable Data Aggregation for Cyber-Physical Sensing

    PubMed Central

    Zhang, Jinhuan; Long, Jun; Zhang, Chengyuan; Zhao, Guihu

    2017-01-01

    Physical information sensed by various sensors in a cyber-physical system should be collected for further operation. In many applications, data aggregation should take reliability and delay into consideration. To address these problems, a novel Tiered Structure Routing-based Delay-Aware and Reliable Data Aggregation scheme named TSR-DARDA for spherical physical objects is proposed. By dividing the spherical network constructed by dispersed sensor nodes into circular tiers with specifically designed widths and cells, TSTR-DARDA tries to enable as many nodes as possible to transmit data simultaneously. In order to ensure transmission reliability, lost packets are retransmitted. Moreover, to minimize the latency while maintaining reliability for data collection, in-network aggregation and broadcast techniques are adopted to deal with the transmission between data collecting nodes in the outer layer and their parent data collecting nodes in the inner layer. Thus, the optimization problem is transformed to minimize the delay under reliability constraints by controlling the system parameters. To demonstrate the effectiveness of the proposed scheme, we have conducted extensive theoretical analysis and comparisons to evaluate the performance of TSR-DARDA. The analysis and simulations show that TSR-DARDA leads to lower delay with reliability satisfaction. PMID:28218668

  14. The reliability and validity of a designed setup for the assessment of static back extensor force and endurance in older women with and without hyperkyphosis.

    PubMed

    Roghani, Taybeh; Khalkhali Zavieh, Minoo; Rahimi, Abbas; Talebian, Saeed; Manshadi, Farideh Dehghan; Akbarzadeh Baghban, Alireza; King, Nicole; Katzman, Wendy

    2018-01-25

    The purpose of this study was to investigate the intra-rater reliability and validity of a designed load cell setup for the measurement of back extensor muscle force and endurance. The study sample included 19 older women with hyperkyphosis, mean age 67.0 ± 5.0 years, and 14 older women without hyperkyphosis, mean age 63.0 ± 6.0 years. Maximum back extensor force and endurance were measured in a sitting position with a designed load cell setup. Tests were performed by the same examiner on two separate days within a 72-hour interval. The intra-rater reliability of the measurements was analyzed using intraclass correlation coefficient (ICC), standard errors of measurement (SEM), and minimal detectable change (MDC). The validity of the setup was determined using Pearson correlation analysis and independent t-test. Using our designed load cell, the values of ICC indicated very high reliability of force measurement (hyperkyphosis group: 0.96, normal group: 0.97) and high reliability of endurance measurement (hyperkyphosis group: 0.82, normal group: 0.89). For all tests, the values of SEM and MDC were low in both groups. A significant correlation between two documented forces (load cell force and target force) and significant differences in the muscle force and endurance among the two groups were found. The measurements of static back muscle force and endurance are reliable and valid with our designed setup in older women with and without hyperkyphosis.

  15. The reliability, precision and clinically meaningful change of walking assessments in multiple sclerosis.

    PubMed

    Learmonth, Yvonne C; Dlugonski, Deirdre D; Pilutti, Lara A; Sandroff, Brian M; Motl, Robert W

    2013-11-01

    Assessing walking impairment in those with multiple sclerosis (MS) is common, however little is known about the reliability, precision and clinically important change of walking outcomes. The purpose of this study was to determine the reliability, precision and clinically important change of the Timed 25-Foot Walk (T25FW), Six-Minute Walk (6MW), Multiple Sclerosis Walking Scale-12 (MSWS-12) and accelerometry. Data were collected from 82 persons with MS at two time points, six months apart. Analyses were undertaken for the whole sample and stratified based on disability level and usage of walking aids. Intraclass correlation coefficient (ICC) analyses established reliability: standard error of measurement (SEM) and coefficient of variation (CV) determined precision; and minimal detectable change (MDC) defined clinically important change. All outcome measures were reliable with precision and MDC varying between measures in the whole sample: T25FW: ICC=0.991; SEM=1 s; CV=6.2%; MDC=2.7 s (36%), 6MW: ICC=0.959; SEM=32 m; CV=6.2%; MDC=88 m (20%), MSWS-12: ICC=0.927; SEM=8; CV=27%; MDC=22 (53%), accelerometry counts/day: ICC=0.883; SEM=28450; CV=17%; MDC=78860 (52%), accelerometry steps/day: ICC=0.907; SEM=726; CV=16%; MDC=2011 (45%). Variation in these estimates was seen based on disability level and walking aid. The reliability of these outcomes is good and falls within acceptable ranges. Precision and clinically important change estimates provide guidelines for interpreting these outcomes in clinical and research settings.

  16. Accurate, reliable prototype earth horizon sensor head

    NASA Technical Reports Server (NTRS)

    Schwarz, F.; Cohen, H.

    1973-01-01

    The design and performance is described of an accurate and reliable prototype earth sensor head (ARPESH). The ARPESH employs a detection logic 'locator' concept and horizon sensor mechanization which should lead to high accuracy horizon sensing that is minimally degraded by spatial or temporal variations in sensing attitude from a satellite in orbit around the earth at altitudes in the 500 km environ 1,2. An accuracy of horizon location to within 0.7 km has been predicted, independent of meteorological conditions. This corresponds to an error of 0.015 deg-at 500 km altitude. Laboratory evaluation of the sensor indicates that this accuracy is achieved. First, the basic operating principles of ARPESH are described; next, detailed design and construction data is presented and then performance of the sensor under laboratory conditions in which the sensor is installed in a simulator that permits it to scan over a blackbody source against background representing the earth space interface for various equivalent plant temperatures.

  17. Development of a versatile user-friendly IBA experimental chamber

    NASA Astrophysics Data System (ADS)

    Kakuee, Omidreza; Fathollahi, Vahid; Lamehi-Rachti, Mohammad

    2016-03-01

    Reliable performance of the Ion Beam Analysis (IBA) techniques is based on the accurate geometry of the experimental setup, employment of the reliable nuclear data and implementation of dedicated analysis software for each of the IBA techniques. It has already been shown that geometrical imperfections lead to significant uncertainties in quantifications of IBA measurements. To minimize these uncertainties, a user-friendly experimental chamber with a heuristic sample positioning system for IBA analysis was recently developed in the Van de Graaff laboratory in Tehran. This system enhances IBA capabilities and in particular Nuclear Reaction Analysis (NRA) and Elastic Recoil Detection Analysis (ERDA) techniques. The newly developed sample manipulator provides the possibility of both controlling the tilt angle of the sample and analyzing samples with different thicknesses. Moreover, a reasonable number of samples can be loaded in the sample wheel. A comparison of the measured cross section data of the 16O(d,p1)17O reaction with the data reported in the literature confirms the performance and capability of the newly developed experimental chamber.

  18. [Interpreting change scores of the Behavioural Rating Scale for Geriatric Inpatients (GIP)].

    PubMed

    Diesfeldt, H F A

    2013-09-01

    The Behavioural Rating Scale for Geriatric Inpatients (GIP) consists of fourteen, Rasch modelled subscales, each measuring different aspects of behavioural, cognitive and affective disturbances in elderly patients. Four additional measures are derived from the GIP: care dependency, apathy, cognition and affect. The objective of the study was to determine the reproducibility of the 18 measures. A convenience sample of 56 patients in psychogeriatric day care was assessed twice by the same observer (a professional caregiver). The median time interval between rating occasions was 45 days (interquartile range 34-58 days). Reproducibility was determined by calculating intraclass correlation coefficients (ICC agreement) for test-retest reliability. The minimal detectable difference (MDD) was calculated based on the standard error of measurement (SEM agreement). Test-retest reliability expressed by the ICCs varied from 0.57 (incoherent behaviour) to 0.93 (anxious behaviour). Standard errors of measurement varied from 0.28 (anxious behaviour) to 1.63 (care dependency). The results show how the GIP can be applied when interpreting individual change in psychogeriatric day care participants.

  19. Ni-MH battery charger with a compensator for electric vehicles

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Park, H.W.; Han, C.S.; Kim, C.S.

    1996-09-01

    The development of a high-performance battery and safe and reliable charging methods are two important factors for commercialization of the Electric Vehicles (EV). Hyundai and Ovonic together spent many years in the research on optimum charging method for Ni-MH battery. This paper presents in detail the results of intensive experimental analysis, performed by Hyundai in collaboration with Ovonic. An on-board Ni-MH battery charger and its controller which are designed to use as a standard home electricity supply are described. In addition, a 3 step constant current recharger with the temperature and the battery aging compensator is proposed. This has amore » multi-loop algorithm function to detect its 80% and fully charged state, and carry out equalization charging control. The algorithm is focused on safety, reliability, efficiency, charging speed and thermal management (maintaining uniform temperatures within a battery pack). It is also designed to minimize the necessity for user input.« less

  20. Optical+Near-IR Bayesian Classification of Quasars

    NASA Astrophysics Data System (ADS)

    Mehta, Sajjan S.; Richards, G. T.; Myers, A. D.

    2011-05-01

    We describe the details of an optimal Bayesian classification of quasars with combined optical+near-IR photometry from the SDSS and UKIDSS LAS surveys. Using only deep co-added SDSS photometry from the "Stripe 82" region and requiring full four-band UKIDSS detections, we reliably identify 2665 quasar candidates with a computed efficiency in excess of 99%. Relaxing the data constraints to combinations of two-band detections yields up to 6424 candidates with minimal trade-off in completeness and efficiency. The completeness and efficiency of the sample are investigated with existing spectra from the SDSS, 2SLAQ, and AUS surveys in addition to recent single-slit observations from Palomar Observatory, which revealed 22 quasars from a subsample of 29 high-z candidates. SDSS-III/BOSS observations will allow further exploration of the completeness/efficiency of the sample over 2.2

  1. Signal Detection Theory Applied to Helicopter Transmission Diagnostic Thresholds

    NASA Technical Reports Server (NTRS)

    Dempsey, Paula J.; Keller, Jonathan A.; Wade, Daniel R.

    2008-01-01

    Helicopter Health Usage Monitoring Systems (HUMS) have potential for providing data to support increasing the service life of a dynamic mechanical component in the transmission of a helicopter. Data collected can demonstrate the HUMS condition indicator responds to a specific component fault with appropriate alert limits and minimal false alarms. Defining thresholds for specific faults requires a tradeoff between the sensitivity of the condition indicator (CI) limit to indicate damage and the number of false alarms. A method using Receiver Operating Characteristic (ROC) curves to assess CI performance was demonstrated using CI data collected from accelerometers installed on several UH60 Black Hawk and AH64 Apache helicopters and an AH64 helicopter component test stand. Results of the analysis indicate ROC curves can be used to reliably assess the performance of commercial HUMS condition indicators to detect damaged gears and bearings in a helicopter transmission.

  2. Signal Detection Theory Applied to Helicopter Transmission Diagnostic Thresholds

    NASA Technical Reports Server (NTRS)

    Dempsey, Paula J.; Keller, Jonathan A.; Wade, Daniel R.

    2009-01-01

    Helicopter Health Usage Monitoring Systems (HUMS) have potential for providing data to support increasing the service life of a dynamic mechanical component in the transmission of a helicopter. Data collected can demonstrate the HUMS condition indicator responds to a specific component fault with appropriate alert limits and minimal false alarms. Defining thresholds for specific faults requires a tradeoff between the sensitivity of the condition indicator (CI) limit to indicate damage and the number of false alarms. A method using Receiver Operating Characteristic (ROC) curves to assess CI performance was demonstrated using CI data collected from accelerometers installed on several UH60 Black Hawk and AH64 Apache helicopters and an AH64 helicopter component test stand. Results of the analysis indicate ROC curves can be used to reliably assess the performance of commercial HUMS condition indicators to detect damaged gears and bearings in a helicopter transmission.

  3. Reliability and number of trials of Y Balance Test in adolescent athletes.

    PubMed

    Linek, Pawel; Sikora, Damian; Wolny, Tomasz; Saulicz, Edward

    2017-10-01

    The Star Excursion Balance Test (SEBT) is commonly used to evaluate dynamic equilibrium. The Y Balance Test (Y-BT) is a shortened version of the SEBT where a Y- Balance Kit is commonly used. To date, research concerning the protocol and reliability of the SEBT and Y-BT has been conducted only for adults. The aim of the study was to assess the protocol (the necessary number of trials to stabilize the results) and reliability of the Y-BT in adolescent athletes. One-way repeated-measures analysis of variance (ANOVA) and reliability study. The sample of 38 athletes (mean age: 15.6 years) was selected from a football club. A Y-Balance test kit was applied for the evaluation of dynamic balance. The analysis used the values normalized to the relative length of the lower limbs. After six attempts, three consecutive ones achieved stability for all directions and both extremities (p > 0.05). The intraclass correlation coefficient (ICC 3,1 ), standard error of measurement and minimal detectable change values for the three attempts ranged from 0.57 to 0.82, from 3 to less than 6% and from 7.68 to 13.7%, respectively. In the study of adolescent dynamic equilibrium using the Y-BT, it is recommended to perform nine attempts (including six trial attempts and three measurements). In order to increase reliability it is recommended that the average of the three measured attempts is analysed. Copyright © 2017 Elsevier Ltd. All rights reserved.

  4. A complementary role of multiparameter flow cytometry and high-throughput sequencing for minimal residual disease detection in chronic lymphocytic leukemia: an European Research Initiative on CLL study.

    PubMed

    Rawstron, A C; Fazi, C; Agathangelidis, A; Villamor, N; Letestu, R; Nomdedeu, J; Palacio, C; Stehlikova, O; Kreuzer, K-A; Liptrot, S; O'Brien, D; de Tute, R M; Marinov, I; Hauwel, M; Spacek, M; Dobber, J; Kater, A P; Gambell, P; Soosapilla, A; Lozanski, G; Brachtl, G; Lin, K; Boysen, J; Hanson, C; Jorgensen, J L; Stetler-Stevenson, M; Yuan, C; Broome, H E; Rassenti, L; Craig, F; Delgado, J; Moreno, C; Bosch, F; Egle, A; Doubek, M; Pospisilova, S; Mulligan, S; Westerman, D; Sanders, C M; Emerson, R; Robins, H S; Kirsch, I; Shanafelt, T; Pettitt, A; Kipps, T J; Wierda, W G; Cymbalista, F; Hallek, M; Hillmen, P; Montserrat, E; Ghia, P

    2016-04-01

    In chronic lymphocytic leukemia (CLL) the level of minimal residual disease (MRD) after therapy is an independent predictor of outcome. Given the increasing number of new agents being explored for CLL therapy, using MRD as a surrogate could greatly reduce the time necessary to assess their efficacy. In this European Research Initiative on CLL (ERIC) project we have identified and validated a flow-cytometric approach to reliably quantitate CLL cells to the level of 0.0010% (10(-5)). The assay comprises a core panel of six markers (i.e. CD19, CD20, CD5, CD43, CD79b and CD81) with a component specification independent of instrument and reagents, which can be locally re-validated using normal peripheral blood. This method is directly comparable to previous ERIC-designed assays and also provides a backbone for investigation of new markers. A parallel analysis of high-throughput sequencing using the ClonoSEQ assay showed good concordance with flow cytometry results at the 0.010% (10(-4)) level, the MRD threshold defined in the 2008 International Workshop on CLL guidelines, but it also provides good linearity to a detection limit of 1 in a million (10(-6)). The combination of both technologies would permit a highly sensitive approach to MRD detection while providing a reproducible and broadly accessible method to quantify residual disease and optimize treatment in CLL.

  5. A comparative study between an improved novel air-cushion sensor and a wheeled probe for minimally invasive surgery.

    PubMed

    Zbyszewski, Dinusha; Challacombe, Benjamin; Li, Jichun; Seneviratne, Lakmal; Althoefer, Kaspar; Dasgupta, Prokar; Murphy, Declan

    2010-07-01

    We describe a comparative study between an enhanced air-cushion tactile sensor and a wheeled indentation probe. These laparoscopic tools are designed to rapidly locate soft-tissue abnormalities during minimally invasive surgery (MIS). The air-cushion tactile sensor consists of an optically based sensor with a 7.8 mm sphere "floating" on a cushion of air at the tip of a shaft. The wheeled indentation probe is a 10 mm wide and 5 mm in diameter wheel mounted to a force/torque sensor. A continuous rolling indentation technique is used to pass the sensors over the soft-tissue surfaces. The variations in stiffness of the viscoelastic materials that are detected during the rolling indentations are illustrated by stiffness maps that can be used for tissue diagnosis. The probes were tested by having to detect four embedded nodules in a silicone phantom. Each probe was attached to a robotic manipulator and rolled over the silicone phantom in parallel paths. The readings of each probe collected during the process of rolling indentation were used to achieve the final results. The results show that both sensors reliably detected the areas of variable stiffness by accurately identifying the location of each nodule. These are illustrated in the form of two three-dimensional spatiomechanical maps. These probes have the potential to be used in MIS because they could provide surgeons with information on the mechanical properties of soft tissue, consequently enhancing the reduction in haptic feedback.

  6. Magneto-impedance based detection of magnetically labeled cancer cells and bio-proteins

    NASA Astrophysics Data System (ADS)

    Devkota, J.; Howell, M.; Mohapatra, S.; Nhung, T. H.; Mukherjee, P.; Srikanth, H.; Phan, M. H.

    2015-03-01

    A magnetic biosensor with enhanced sensitivity and immobilized magnetic markers is essential for a reliable analysis of the presence of a biological entity in a fluid. Based on conventional approaches, however, it is quite challenging to create such a sensor. We report on a novel magnetic biosensor using the magneto-impedance (MI) effect of a Co-based amorphous ribbon with a microhole-patterned surface that fulfils these requirements. The sensor probe was fabricated by patterning four microholes, each of diameter 2 μm and depth 2 μm, on the ribbon surface using FIB lithography. The magnetically labeled Luis Lung Carcinoma (LLC) cancer cells and Bovine serum albumin (BSA) proteins were drop-casted on the ribbon surface, and MI was measured over 0.1 - 10 MHz frequency range. As the analytes were trapped into the microholes, their physical motion was minimized and interaction among the magnetic fields was strengthened, thus yielding a more reliable and sensitive detection of the biological entities. The presence of magnetically labeled LLC cells (8.25x105 cells/ml, 10 μl) and BSA proteins (2x1011 particles/ml, 10 μl) were found to result in a ~ 2% change in MI with respect to the reference signal.

  7. Simple, Script-Based Science Processing Archive

    NASA Technical Reports Server (NTRS)

    Lynnes, Christopher; Hegde, Mahabaleshwara; Barth, C. Wrandle

    2007-01-01

    The Simple, Scalable, Script-based Science Processing (S4P) Archive (S4PA) is a disk-based archival system for remote sensing data. It is based on the data-driven framework of S4P and is used for data transfer, data preprocessing, metadata generation, data archive, and data distribution. New data are automatically detected by the system. S4P provides services such as data access control, data subscription, metadata publication, data replication, and data recovery. It comprises scripts that control the data flow. The system detects the availability of data on an FTP (file transfer protocol) server, initiates data transfer, preprocesses data if necessary, and archives it on readily available disk drives with FTP and HTTP (Hypertext Transfer Protocol) access, allowing instantaneous data access. There are options for plug-ins for data preprocessing before storage. Publication of metadata to external applications such as the Earth Observing System Clearinghouse (ECHO) is also supported. S4PA includes a graphical user interface for monitoring the system operation and a tool for deploying the system. To ensure reliability, S4P continuously checks stored data for integrity, Further reliability is provided by tape backups of disks made once a disk partition is full and closed. The system is designed for low maintenance, requiring minimal operator oversight.

  8. On Reliable and Efficient Data Gathering Based Routing in Underwater Wireless Sensor Networks.

    PubMed

    Liaqat, Tayyaba; Akbar, Mariam; Javaid, Nadeem; Qasim, Umar; Khan, Zahoor Ali; Javaid, Qaisar; Alghamdi, Turki Ali; Niaz, Iftikhar Azim

    2016-08-30

    This paper presents cooperative routing scheme to improve data reliability. The proposed protocol achieves its objective, however, at the cost of surplus energy consumption. Thus sink mobility is introduced to minimize the energy consumption cost of nodes as it directly collects data from the network nodes at minimized communication distance. We also present delay and energy optimized versions of our proposed RE-AEDG to further enhance its performance. Simulation results prove the effectiveness of our proposed RE-AEDG in terms of the selected performance matrics.

  9. Electrical termination techniques

    NASA Technical Reports Server (NTRS)

    Oakey, W. E.; Schleicher, R. R.

    1976-01-01

    A technical review of high reliability electrical terminations for electronic equipment was made. Seven techniques were selected from this review for further investigation, experimental work, and preliminary testing. From the preliminary test results, four techniques were selected for final testing and evaluation. These four were: (1) induction soldering, (2) wire wrap, (3) percussive arc welding, and (4) resistance welding. Of these four, induction soldering was selected as the best technique in terms of minimizing operator errors, controlling temperature and time, minimizing joint contamination, and ultimately producing a reliable, uniform, and reusable electrical termination.

  10. Improvements in Near-Terminator and Nocturnal Cloud Masks using Satellite Imager Data over the Atmospheric Radiation Measurement Sites

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Trepte, Q.Z.; Minnis, P.; Heck, P.W.

    2005-03-18

    Cloud detection using satellite measurements presents a big challenge near the terminator where the visible (VIS; 0.65 {micro}m) channel becomes less reliable and the reflected solar component of the solar infrared 3.9-{micro}m channel reaches very low signal-to-noise ratio levels. As a result, clouds are underestimated near the terminator and at night over land and ocean in previous Atmospheric Radiation Measurement (ARM) Program cloud retrievals using Geostationary Operational Environmental Satellite (GOES) imager data. Cloud detection near the terminator has always been a challenge. For example, comparisons between the CLAVR-x (Clouds from Advanced Very High Resolution Radiometer [AVHRR]) cloud coverage and Geosciencemore » Laser Altimeter System (GLAS) measurements north of 60{sup o}N indicate significant amounts of missing clouds from AVHRR because this part of the world was near the day/night terminator viewed by AVHRR. Comparisons between MODIS cloud products and GLAS at the same regions also shows the same difficulty in the MODIS cloud retrieval (Pavolonis and Heidinger 2005). Consistent detection of clouds at all times of day is needed to provide reliable cloud and radiation products for ARM and other research efforts involving the modeling of clouds and their interaction with the radiation budget. To minimize inconsistencies between daytime and nighttime retrievals, this paper develops an improved twilight and nighttime cloud mask using GOES-9, 10, and 12 imager data over the ARM sites and the continental United States (CONUS).« less

  11. Improvements in Near-Terminator and Nocturnal Cloud Masks using Satellite Image Data over the Atmospheric Radiation Measurement Sites

    NASA Technical Reports Server (NTRS)

    Trepte, Q. Z.; Minnis, P.; Heck, R. W.; Palikonda, R.

    2005-01-01

    Cloud detection using satellite measurements presents a big challenge near the terminator where the visible (VIS; 0.65 (micro)m) channel becomes less reliable and the reflected solar component of the solar infrared 3.9-(micro)m channel reaches very low signal-to-noise ratio levels. As a result, clouds are underestimated near the terminator and at night over land and ocean in previous Atmospheric Radiation Measurement (ARM) Program cloud retrievals using Geostationary Operational Environmental Satellite (GOES) imager data. Cloud detection near the terminator has always been a challenge. For example, comparisons between the CLAVR-x (Clouds from Advanced Very High Resolution Radiometer (AVHRR)) cloud coverage and Geoscience Laser Altimeter System (GLAS) measurements north of 60 degrees N indicate significant amounts of missing clouds from AVHRR because this part of the world was near the day/night terminator viewed by AVHRR. Comparisons between MODIS cloud products and GLAS at the same regions also shows the same difficulty in the MODIS cloud retrieval (Pavolonis and Heidinger 2005). Consistent detection of clouds at all times of day is needed to provide reliable cloud and radiation products for ARM and other research efforts involving the modeling of clouds and their interaction with the radiation budget. To minimize inconsistencies between daytime and nighttime retrievals, this paper develops an improved twilight and nighttime cloud mask using GOES-9, 10, and 12 imager data over the ARM sites and the continental United States (CONUS).

  12. Cross-Cultural Translation, Adaptation and Reliability of the Danish M. D. Andeson Dysphagia Inventory (MDADI) in Patients with Head and Neck Cancer.

    PubMed

    Hajdú, Sara Fredslund; Plaschke, Christina Caroline; Johansen, Christoffer; Dalton, Susanne Oksbjerg; Wessel, Irene

    2017-08-01

    The objectives were to translate and culturally adapt the M.D. Anderson Dysphagia Inventory (MDADI) into Danish and subsequently test the reliability of the Danish version. The MDADI was translated into Danish and cross culturally adapted through cognitive interviews. The final version was test-retest evaluated in a group of head and neck cancer (HNC) patients who responded to the questionnaire twice with a mean of eight days apart. Interclass correlation coefficient, Cronbach's alpha, floor and ceiling effects, standard error of measurement and minimal detectable change were investigated. Fourteen patients were interviewed on the comprehensibility of the Danish MDADI, and all found the questionnaire meaningful, easy to understand, non-offensive and to include relevant aspects of dysphagia related to HNC. Sixty-four patients were included in the test-retest study. Especially, one item in the emotional scale (E7) appeared to be often misinterpreted, and ceiling effects were found in all four subdomains (global, emotional, functional and physical). The four subdomains and the composite score showed acceptable test-retest reliability and internal consistency in a Danish population of HNC patients. The Danish MDADI is reliable in terms of internal consistency and test-retest reproducibility and can be used in assessing the health-related quality of life in head and neck cancer patients with dysphagia.

  13. Reliability and Validity Study of the Chamorro Assisted Gait Scale for People with Sprained Ankles, Walking with Forearm Crutches

    PubMed Central

    Ridao-Fernández, Carmen; Ojeda, Joaquín; Benítez-Lugo, Marisa; Sevillano, José Luis

    2016-01-01

    Objective The aim of this study was to design and validate a functional assessment scale for assisted gait with forearm crutches (Chamorro Assisted Gait Scale—CHAGS) and to assess its reliability in people with sprained ankles. Design Thirty subjects who suffered from sprained ankle (anterior talofibular ligament first and second degree) were included in the study. A modified Delphi technique was used to obtain the content validity. The selected items were: pelvic and scapular girdle dissociation(1), deviation of Center of Gravity(2), crutch inclination(3), steps rhythm(4), symmetry of step length(5), cross support(6), simultaneous support of foot and crutch(7), forearm off(8), facing forward(9) and fluency(10). Two raters twice visualized the gait of the sample subjects which were recorded. The criterion-related validity was determined by correlation between CHAGS and Coding of eight criteria of qualitative gait analysis (Viel Coding). Internal consistency and inter and intra-rater reliability were also tested. Results CHAGS obtained a high and negative correlation with Viel Coding. We obtained a good internal consistency and the intra-class correlation coefficients oscillated between 0.97 and 0.99, while the minimal detectable changes were acceptable. Conclusion CHAGS scale is a valid and reliable tool for assessing assisted gait with crutches in people with sprained ankles to perform partial relief of lower limbs. PMID:27168236

  14. Reliability, Concurrent Validity, and Minimal Detectable Change for iPhone Goniometer App in Assessing Knee Range of Motion.

    PubMed

    Mehta, Saurabh P; Barker, Katherine; Bowman, Brett; Galloway, Heather; Oliashirazi, Nicole; Oliashirazi, Ali

    2017-07-01

    Much of the published works assessing the reliability of smartphone goniometer apps (SG) have poor generalizability since the reliability was assessed in healthy subjects. No research has established the values for standard error of measurement (SEM) or minimal detectable change (MDC) which have greater clinical utility to contextualize the range of motion (ROM) assessed using the SG. This research examined the test-retest reproducibility, concurrent validity, SEM, and MDC values for the iPhone goniometer app (i-Goni; June Software Inc., v.1.1, San Francisco, CA) in assessing knee ROM in patients with knee osteoarthritis or those after total knee replacement. A total of 60 participants underwent data collection which included the assessment of active knee ROM using the i-Goni and the universal goniometer (UG; EZ Read Jamar Goniometer, Patterson Medical, Warrenville, IL), knee muscle strength, and assessment of pain and lower extremity disability using quadruple numeric pain rating scale (Q-NPRS) and lower extremity functional scale (LEFS), respectively. Intraclass correlation coefficients (ICCs) were calculated to assess the reproducibility of the knee ROM assessed using the i-Goni and UG. Bland and Altman technique examined the agreement between these knee ROM. The SEM and MDC values were calculated for i-Goni assessed knee ROM to characterize the error in a single score and the index of true change, respectively. Pearson correlation coefficient examined concurrent relationships between the i-Goni and other measures. The ICC values for the knee flexion/extension ROM were superior for i-Goni (0.97/0.94) compared with the UG (0.95/0.87). The SEM values were smaller for i-Goni assessed knee flexion/extension (2.72/1.18 degrees) compared with UG assessed knee flexion/extension (3.41/1.62 degrees). Similarly, the MDC values were smaller for both these ROM for the i-Goni (6.3 and 2.72 degrees) suggesting smaller change required to infer true change in knee ROM. The i-Goni assessed knee ROM showed expected concurrent relationships with UG, knee muscle strength, Q-NPRS, and the LEFS. In conclusion, the i-Goni demonstrated superior reproducibility with smaller measurement error compared with UG in assessing knee ROM in the recruited cohort. Future research can expand the inquiry for assessing the reliability of the i-Goni to other joints. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  15. Reliability of sensor-based real-time workflow recognition in laparoscopic cholecystectomy.

    PubMed

    Kranzfelder, Michael; Schneider, Armin; Fiolka, Adam; Koller, Sebastian; Reiser, Silvano; Vogel, Thomas; Wilhelm, Dirk; Feussner, Hubertus

    2014-11-01

    Laparoscopic cholecystectomy is a very common minimally invasive surgical procedure that may be improved by autonomous or cooperative assistance support systems. Model-based surgery with a precise definition of distinct procedural tasks (PT) of the operation was implemented and tested to depict and analyze the process of this procedure. Reliability of real-time workflow recognition in laparoscopic cholecystectomy ([Formula: see text] cases) was evaluated by continuous sensor-based data acquisition. Ten PTs were defined including begin/end preparation calots' triangle, clipping/cutting cystic artery and duct, begin/end gallbladder dissection, begin/end hemostasis, gallbladder removal, and end of operation. Data acquisition was achieved with continuous instrument detection, room/table light status, intra-abdominal pressure, table tilt, irrigation/aspiration volume and coagulation/cutting current application. Two independent observers recorded start and endpoint of each step by analysis of the sensor data. The data were cross-checked with laparoscopic video recordings serving as gold standard for PT identification. Bland-Altman analysis revealed for 95% of cases a difference of annotation results within the limits of agreement ranging from [Formula: see text]309 s (PT 7) to +368 s (PT 5). Laparoscopic video and sensor data matched to a greater or lesser extent within the different procedural tasks. In the majority of cases, the observer results exceeded those obtained from the laparoscopic video. Empirical knowledge was required to detect phase transit. A set of sensors used to monitor laparoscopic cholecystectomy procedures was sufficient to enable expert observers to reliably identify each PT. In the future, computer systems may automate the task identification process provided a more robust data inflow is available.

  16. Magnetically operated limit switch has improved reliability, minimizes arcing

    NASA Technical Reports Server (NTRS)

    Steiner, R.

    1966-01-01

    Limit switch for reliable, low-travel, snap action with negligible arcing uses an electrically nonconductive permanent magnet consisting of a ferrimagnetic ceramic and ferromagnetic pole shoes which form a magnetic and electrically conductive circuit with a ferrous-metal armature.

  17. RELIABILITY OF ANKLE-FOOT MORPHOLOGY, MOBILITY, STRENGTH, AND MOTOR PERFORMANCE MEASURES.

    PubMed

    Fraser, John J; Koldenhoven, Rachel M; Saliba, Susan A; Hertel, Jay

    2017-12-01

    Assessment of foot posture, morphology, intersegmental mobility, strength and motor control of the ankle-foot complex are commonly used clinically, but measurement properties of many assessments are unclear. To determine test-retest and inter-rater reliability, standard error of measurement, and minimal detectable change of morphology, joint excursion and play, strength, and motor control of the ankle-foot complex. Reliability study. 24 healthy, recreationally-active young adults without history of ankle-foot injury were assessed by two clinicians on two occasions, three to ten days apart. Measurement properties were assessed for foot morphology (foot posture index, total and truncated length, width, arch height), joint excursion (weight-bearing dorsiflexion, rearfoot and hallux goniometry, forefoot inclinometry, 1 st metatarsal displacement) and joint play, strength (handheld dynamometry), and motor control rating during intrinsic foot muscle (IFM) exercises. Clinician order was randomized using a Latin Square. The clinicians performed independent examinations and did not confer on the findings for the duration of the study. Test-retest and inter-tester reliability and agreement was assessed using intraclass correlation coefficients (ICC 2,k ) and weighted kappa ( K w ). Test-retest reliability ICC were as follows: morphology: .80-1.00, joint excursion: .58-.97, joint play: -.67-.84, strength: .67-.92, IFM motor rating: K W -.01-.71. Inter-rater reliability ICC were as follows: morphology: .81-1.00, joint excursion: .32-.97, joint play: -1.06-1.00, strength: .53-.90, and IFM motor rating: K w .02-.56. Measures of ankle-foot posture, morphology, joint excursion, and strength demonstrated fair to excellent test-retest and inter-rater reliability. Test-retest reliability for rating of perceived difficulty and motor performance was good to excellent for short-foot, toe-spread-out, and hallux exercises and poor to fair for lesser toe extension. Joint play measures had poor to fair reliability overall. The findings of this study should be considered when choosing methods of clinical assessment and outcome measures in practice and research. 3.

  18. Assessment of Lower Limb Muscle Strength and Power Using Hand-Held and Fixed Dynamometry: A Reliability and Validity Study

    PubMed Central

    Perraton, Luke G.; Bower, Kelly J.; Adair, Brooke; Pua, Yong-Hao; Williams, Gavin P.; McGaw, Rebekah

    2015-01-01

    Introduction Hand-held dynamometry (HHD) has never previously been used to examine isometric muscle power. Rate of force development (RFD) is often used for muscle power assessment, however no consensus currently exists on the most appropriate method of calculation. The aim of this study was to examine the reliability of different algorithms for RFD calculation and to examine the intra-rater, inter-rater, and inter-device reliability of HHD as well as the concurrent validity of HHD for the assessment of isometric lower limb muscle strength and power. Methods 30 healthy young adults (age: 23±5yrs, male: 15) were assessed on two sessions. Isometric muscle strength and power were measured using peak force and RFD respectively using two HHDs (Lafayette Model-01165 and Hoggan microFET2) and a criterion-reference KinCom dynamometer. Statistical analysis of reliability and validity comprised intraclass correlation coefficients (ICC), Pearson correlations, concordance correlations, standard error of measurement, and minimal detectable change. Results Comparison of RFD methods revealed that a peak 200ms moving window algorithm provided optimal reliability results. Intra-rater, inter-rater, and inter-device reliability analysis of peak force and RFD revealed mostly good to excellent reliability (coefficients ≥ 0.70) for all muscle groups. Concurrent validity analysis showed moderate to excellent relationships between HHD and fixed dynamometry for the hip and knee (ICCs ≥ 0.70) for both peak force and RFD, with mostly poor to good results shown for the ankle muscles (ICCs = 0.31–0.79). Conclusions Hand-held dynamometry has good to excellent reliability and validity for most measures of isometric lower limb strength and power in a healthy population, particularly for proximal muscle groups. To aid implementation we have created freely available software to extract these variables from data stored on the Lafayette device. Future research should examine the reliability and validity of these variables in clinical populations. PMID:26509265

  19. High-resolution surface plasmon resonance biosensing system for glucose concentration detecting

    NASA Astrophysics Data System (ADS)

    Huang, Xian; Li, Dachao; Yu, Haixia; Huang, Fuxiang; Hu, Xiaotang; Xu, Kexin

    2007-02-01

    Glucose is one of the most important substances widely contained in organism and food, thus people pay much attention in researching and improving the way for the detection of glucose. Traditional ways, although precise and reliable when in high concentration and large amount of sample, have unconvincing performance in detecting mixture and solution with low concentration and micro-volume. As far as the ideal way is concerned, it should not only specifically detect the glucose and exclude other components in solution, but also meet the need of micro-sample (approximately 5μL) and low concentration. We introduced D-galactose/D-glucose Binding Protein (GGBP) - a kind of protein which has the ability to absorb the glucose specifically, to construct a novel surface plasmon resonance measuring system. By immobilizing GGBP onto the surface of the SPR sensor, we develop a new detecting system for glucose testing in mixed solution. The experimental result indicates that compared with 0.1g/L before immobilization of GGBP, the detecting limit or the resolution of glucose testing rises to 1mg/L after the immobilization, the system succeeds in distinguishing glucose from other components in mixture, which reveals a bright future to apply SPR in the minimally invasive diabetes testing and food quality control.

  20. Columbus safety and reliability

    NASA Astrophysics Data System (ADS)

    Longhurst, F.; Wessels, H.

    1988-10-01

    Analyses carried out to ensure Columbus reliability, availability, and maintainability, and operational and design safety are summarized. Failure modes/effects/criticality is the main qualitative tool used. The main aspects studied are fault tolerance, hazard consequence control, risk minimization, human error effects, restorability, and safe-life design.

  1. Assessment of physical server reliability in multi cloud computing system

    NASA Astrophysics Data System (ADS)

    Kalyani, B. J. D.; Rao, Kolasani Ramchand H.

    2018-04-01

    Business organizations nowadays functioning with more than one cloud provider. By spreading cloud deployment across multiple service providers, it creates space for competitive prices that minimize the burden on enterprises spending budget. To assess the software reliability of multi cloud application layered software reliability assessment paradigm is considered with three levels of abstractions application layer, virtualization layer, and server layer. The reliability of each layer is assessed separately and is combined to get the reliability of multi-cloud computing application. In this paper, we focused on how to assess the reliability of server layer with required algorithms and explore the steps in the assessment of server reliability.

  2. Advanced Signal Conditioners for Data-Acquisition Systems

    NASA Technical Reports Server (NTRS)

    Lucena, Angel; Perotti, Jose; Eckhoff, Anthony; Medelius, Pedro

    2004-01-01

    Signal conditioners embodying advanced concepts in analog and digital electronic circuitry and software have been developed for use in data-acquisition systems that are required to be compact and lightweight, to utilize electric energy efficiently, and to operate with high reliability, high accuracy, and high power efficiency, without intervention by human technicians. These signal conditioners were originally intended for use aboard spacecraft. There are also numerous potential terrestrial uses - especially in the fields of aeronautics and medicine, wherein it is necessary to monitor critical functions. Going beyond the usual analog and digital signal-processing functions of prior signal conditioners, the new signal conditioner performs the following additional functions: It continuously diagnoses its own electronic circuitry, so that it can detect failures and repair itself (as described below) within seconds. It continuously calibrates itself on the basis of a highly accurate and stable voltage reference, so that it can continue to generate accurate measurement data, even under extreme environmental conditions. It repairs itself in the sense that it contains a micro-controller that reroutes signals among redundant components as needed to maintain the ability to perform accurate and stable measurements. It detects deterioration of components, predicts future failures, and/or detects imminent failures by means of a real-time analysis in which, among other things, data on its present state are continuously compared with locally stored historical data. It minimizes unnecessary consumption of electric energy. The design architecture divides the signal conditioner into three main sections: an analog signal section, a digital module, and a power-management section. The design of the analog signal section does not follow the traditional approach of ensuring reliability through total redundancy of hardware: Instead, following an approach called spare parts tool box, the reliability of each component is assessed in terms of such considerations as risks of damage, mean times between failures, and the effects of certain failures on the performance of the signal conditioner as a whole system. Then, fewer or more spares are assigned for each affected component, pursuant to the results of this analysis, in order to obtain the required degree of reliability of the signal conditioner as a whole system. The digital module comprises one or more processors and field-programmable gate arrays, the number of each depending on the results of the aforementioned analysis. The digital module provides redundant control, monitoring, and processing of several analog signals. It is designed to minimize unnecessary consumption of electric energy, including, when possible, going into a low-power "sleep" mode that is implemented in firmware. The digital module communicates with external equipment via a personal-computer serial port. The digital module monitors the "health" of the rest of the signal conditioner by processing defined measurements and/or trends. It automatically makes adjustments to respond to channel failures, compensate for effects of temperature, and maintain calibration.

  3. Ion-trajectory analysis for micromotion minimization and the measurement of small forces

    NASA Astrophysics Data System (ADS)

    Gloger, Timm F.; Kaufmann, Peter; Kaufmann, Delia; Baig, M. Tanveer; Collath, Thomas; Johanning, Michael; Wunderlich, Christof

    2015-10-01

    For experiments with ions confined in a Paul trap, minimization of micromotion is often essential. In order to diagnose and compensate micromotion we have implemented a method that allows for finding the position of the radio-frequency (rf) null reliably and efficiently, in principle, without any variation of direct current (dc) voltages. We apply a trap modulation technique and focus-scanning imaging to extract three-dimensional ion positions for various rf drive powers and analyze the power dependence of the equilibrium position of the trapped ion. In contrast to commonly used methods, the search algorithm directly makes use of a physical effect as opposed to efficient numerical minimization in a high-dimensional parameter space. Using this method we achieve a compensation of the residual electric field that causes excess micromotion in the radial plane of a linear Paul trap down to 0.09 Vm-1 . Additionally, the precise position determination of a single harmonically trapped ion employed here can also be utilized for the detection of small forces. This is demonstrated by determining light pressure forces with a precision of 135 yN. As the method is based on imaging only, it can be applied to several ions simultaneously and is independent of laser direction and thus well suited to be used with, for example, surface-electrode traps.

  4. Sustainable, Reliable Mission-Systems Architecture

    NASA Technical Reports Server (NTRS)

    O'Neil, Graham; Orr, James K.; Watson, Steve

    2005-01-01

    A mission-systems architecture, based on a highly modular infrastructure utilizing open-standards hardware and software interfaces as the enabling technology is essential for affordable md sustainable space exploration programs. This mission-systems architecture requires (8) robust communication between heterogeneous systems, (b) high reliability, (c) minimal mission-to-mission reconfiguration, (d) affordable development, system integration, end verification of systems, and (e) minimal sustaining engineering. This paper proposes such an architecture. Lessons learned from the Space Shuttle program and Earthbound complex engineered systems are applied to define the model. Technology projections reaching out 5 years are made to refine model details.

  5. Sustainable, Reliable Mission-Systems Architecture

    NASA Technical Reports Server (NTRS)

    O'Neil, Graham; Orr, James K.; Watson, Steve

    2007-01-01

    A mission-systems architecture, based on a highly modular infrastructure utilizing: open-standards hardware and software interfaces as the enabling technology is essential for affordable and sustainable space exploration programs. This mission-systems architecture requires (a) robust communication between heterogeneous system, (b) high reliability, (c) minimal mission-to-mission reconfiguration, (d) affordable development, system integration, and verification of systems, and (e) minimal sustaining engineering. This paper proposes such an architecture. Lessons learned from the Space Shuttle program and Earthbound complex engineered system are applied to define the model. Technology projections reaching out 5 years are mde to refine model details.

  6. Demonstration of the test-retest reliability and sensitivity of the Lower Limb Functional Index-10 as a measure of functional recovery post burn injury: a cross-sectional repeated measures study design.

    PubMed

    Ryland, Margaret E; Grisbrook, Tiffany L; Wood, Fiona M; Phillips, Michael; Edgar, Dale W

    2016-01-01

    Lower limb burns can significantly delay recovery of function. Measuring lower limb functional outcomes is challenging in the unique burn patient population and necessitates the use of reliable and valid tools. The aims of this study were to examine the test-retest reliability, sensitivity, and internal consistency of Sections 1 and 3 of the Lower Limb Functional Index-10 (LLFI-10) questionnaire for measuring functional ability in patients with lower limb burns over time. Twenty-nine adult patients who had sustained a lower limb burn injury in the previous 12 months completed the test-retest procedure of the study. In addition, the minimal detectable change (MDC) was calculated for Section 1 and 3 of the LLFI-10. Section 1 is focused on the activity limitations experienced by patients with a lower limb disorder whereas Section 3 involves patients indicating their current percentage of pre-injury duties. Section 1 of the LLFI-10 demonstrated excellent test-retest reliability (intra-class correlation coefficient (ICC) 0.98, 95 % CI 0.96-0.99) whilst Section 3 demonstrated high test-retest reliability (ICC 0.88, 95 % CI 0.79-0.94). MDC scores for Sections 1 and 3 were 1.27 points and 30.22 %, respectively. Internal consistency was demonstrated with a significant negative association (r s  = -0.83) between Sections 1 and 3 of the LLFI-10 (p < 0.001). This study demonstrates that Section 1 and 3 of the LLFI-10 are reliable for measuring functional ability in patients who have sustained lower limb burns in the previous 12 months, and furthermore, Section 1 is sensitive to changes in patient function over time.

  7. Validity and reliability of the Dutch version of the Copenhagen Hip And Groin Outcome Score (HAGOS-NL) in patients with hip pathology.

    PubMed

    Giezen, Hilde; Stevens, Martin; van den Akker-Scheek, Inge; Reininga, Inge H F

    2017-01-01

    The Copenhagen Hip And Groin Outcome Score (HAGOS) was developed to assess disease-specific consequences in young to middle-aged, physically active hip and/or groin patients. The study aimed to determine validity and reliability of the Dutch version of the HAGOS (HAGOS-NL) for middle-aged patients with hip complaints. To assess validity, 117 participants completed five questionnaires: HAGOS-NL, international Hip Outcome Tool (iHOT-12NL), Hip disability and Osteoarthritis Outcome Score (HOOS), RAND-36 Health Survey and Tegner activity scale. Structural validity was determined by conducting confirmatory factor analysis. Construct validity was analyzed by formulating predefined hypotheses regarding relationships between the HAGOS-NL and subscales of the iHOT-12NL, HOOS, RAND-36 and Tegner activity scale. The HAGOS-NL was filled out again by 67 patients to explore test-retest reliability. Reliability was assessed in terms of Cronbach's alpha, Intraclass Correlation Coefficient (ICC), Standard Error of Measurement (SEM) and Minimal Detectable Change (MDC). The Bland and Altman method was used to explore absolute agreement. Factor analysis confirmed that the HAGOS-NL consists of six subscales. All hypotheses were confirmed, indicating good construct validity. Internal consistency was good, with Cronbach's alpha values ranging from 0.89 to 0.98. Test-retest reliability was considered good, with ICC values of 0.80 and higher. The SEM ranged from 6.6 to 12.3, and MDC at individual level from 18.3 to 34.1 and at group level from 2.3 to 4.4. Bland and Altman analyses showed no bias. The HAGOS-NL is a reliable and valid instrument for measuring pain, physical functioning and quality of life in middle-aged patients with hip complaints.

  8. Validity and reliability of a Dutch version of the Foot and Ankle Ability Measure.

    PubMed

    Weel, Hanneke; Zwiers, Ruben; Azim, Donija; Sierevelt, Inger N; Haverkamp, Daniel; van Dijk, C Niek; Kerkhoffs, Gino M M J

    2016-04-01

    The aim of the study was to develop a Dutch language version of the Foot and Ankle Ability Measure (FAAM) and evaluate its measurement properties according to the consensus-based standards for the selection of health measurement instruments (COSMIN) definitions. A forward-backward translation procedure was performed and subsequently the Dutch version of the FAAM was evaluated for its reliability and validity in 369 patients with a variety of foot and ankle complaints. The reliability was assessed by calculating the intraclass correlation coefficients (ICC, test-retest reliability), Cronbach's alpha (internal consistency), the standard error of measurement and the minimal detectable change (MDC). Additionally, this was done for athletes. The construct validity was assessed by the use of Spearman's correlation coefficient between FAAM domains and similar and contradictory domains of the Foot and Ankle Outcome Score, Short Form 36 and the Numeric Rating Scale for pain. The ICC of the subscales ranged from 0.62 to 0.86. Cronbach's alpha's minimum was 0.97. At individual level, the MDC ranged from 23.9 to 44.7 and at group level from 2.77 to 4.32. In the subgroup of athletes, the reliability was higher. The hypothesized correlations of the construct validity were supported by an 80% confirmation rate. The Dutch version of the FAAM met adequate measurement properties, although the reliability is not optimal. The FAAM-Sport subscale is more useful in athletes and the FAAM-Sport % seems not to contribute. In athletes with various foot and ankle symptoms, the FAAM can be used for functional assessment and follow-up at group level. For the general population, the FAAM is less appropriate. Diagnostic study, Level I.

  9. Use of a tibial accelerometer to measure ground reaction force in running: A reliability and validity comparison with force plates.

    PubMed

    Raper, Damian P; Witchalls, Jeremy; Philips, Elissa J; Knight, Emma; Drew, Michael K; Waddington, Gordon

    2018-01-01

    The use of microsensor technologies to conduct research and implement interventions in sports and exercise medicine has increased recently. The objective of this paper was to determine the validity and reliability of the ViPerform as a measure of load compared to vertical ground reaction force (GRF) as measured by force plates. Absolute reliability assessment, with concurrent validity. 10 professional triathletes ran 10 trials over force plates with the ViPerform mounted on the mid portion of the medial tibia. Calculated vertical ground reaction force data from the ViPerform was matched to the same stride on the force plate. Bland-Altman (BA) plot of comparative measure of agreement was used to assess the relationship between the calculated load from the accelerometer and the force plates. Reliability was calculated by intra-class correlation coefficients (ICC) with 95% confidence intervals. BA plot indicates minimal agreement between the measures derived from the force plate and ViPerform, with variation at an individual participant plot level. Reliability was excellent (ICC=0.877; 95% CI=0.825-0.917) in calculating the same vertical GRF in a repeated trial. Standard error of measure (SEM) equalled 99.83 units (95% CI=82.10-119.09), which, in turn, gave a minimum detectable change (MDC) value of 276.72 units (95% CI=227.32-330.07). The ViPerform does not calculate absolute values of vertical GRF similar to those measured by a force plate. It does provide a valid and reliable calculation of an athlete's lower limb load at constant velocity. Copyright © 2017 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  10. Clinimetric properties of the Tinetti Mobility Test, Four Square Step Test, Activities-specific Balance Confidence Scale, and spatiotemporal gait measures in individuals with Huntington's disease

    PubMed Central

    Kloos, Anne D.; Fritz, Nora E.; Kostyk, Sandra K.; Young, Gregory S.; Kegelmeyer, Deb A.

    2014-01-01

    Background and purpose Individuals with Huntington's disease (HD) experience balance and gait problems that lead to falls. Clinicians currently have very little information about the reliability and validity of outcome measures to determine the efficacy of interventions that aim to reduce balance and gait impairments in HD. This study examined the reliability and concurrent validity of spatiotemporal gait measures, the Tinetti Mobility Test (TMT), Four Square Step Test (FSST), and Activities-specific Balance Confidence (ABC) Scale in individuals with HD. Methods Participants with HD [n = 20; mean age ± SD = 50.9 ± 13.7; 7 male] were tested on spatiotemporal gait measures the TMT, FSST, and ABC Scale before and after a six week period to determine test–retest reliability and minimal detectable change (MDC) values. Linear relationships between gait and clinical measures were estimated using Pearson's correlation coefficients. Results Spatiotemporal gait measures, the TMT total and the FSST showed good to excellent test–retest reliability (ICC > 0.75). MDC values were 0.30 m/s and 0.17 m/s for velocity in forward and backward walking respectively, four points for the TMT, and 3 s for the FSST. The TMT and FSST were highly correlated with most spatiotemporal measures. The ABC Scale demonstrated lower reliability and less concurrent validity than other measures. Conclusions The high test–retest reliability over a six week period and concurrent validity between the TMT, FSST, and spatiotemporal gait measures suggest that the TMT and FSST may be useful outcome measures for future intervention studies in ambulatory individuals with HD. PMID:25128156

  11. Clinimetric properties of the Tinetti Mobility Test, Four Square Step Test, Activities-specific Balance Confidence Scale, and spatiotemporal gait measures in individuals with Huntington's disease.

    PubMed

    Kloos, Anne D; Fritz, Nora E; Kostyk, Sandra K; Young, Gregory S; Kegelmeyer, Deb A

    2014-09-01

    Individuals with Huntington's disease (HD) experience balance and gait problems that lead to falls. Clinicians currently have very little information about the reliability and validity of outcome measures to determine the efficacy of interventions that aim to reduce balance and gait impairments in HD. This study examined the reliability and concurrent validity of spatiotemporal gait measures, the Tinetti Mobility Test (TMT), Four Square Step Test (FSST), and Activities-specific Balance Confidence (ABC) Scale in individuals with HD. Participants with HD [n = 20; mean age ± SD=50.9 ± 13.7; 7 male] were tested on spatiotemporal gait measures and the TMT, FSST, and ABC Scale before and after a six week period to determine test-retest reliability and minimal detectable change (MDC) values. Linear relationships between gait and clinical measures were estimated using Pearson's correlation coefficients. Spatiotemporal gait measures, the TMT total and the FSST showed good to excellent test-retest reliability (ICC > 0.75). MDC values were 0.30 m/s and 0.17 m/s for velocity in forward and backward walking respectively, four points for the TMT, and 3s for the FSST. The TMT and FSST were highly correlated with most spatiotemporal measures. The ABC Scale demonstrated lower reliability and less concurrent validity than other measures. The high test-retest reliability over a six week period and concurrent validity between the TMT, FSST, and spatiotemporal gait measures suggest that the TMT and FSST may be useful outcome measures for future intervention studies in ambulatory individuals with HD. Copyright © 2014 Elsevier B.V. All rights reserved.

  12. The prone bridge test: Performance, validity, and reliability among older and younger adults.

    PubMed

    Bohannon, Richard W; Steffl, Michal; Glenney, Susan S; Green, Michelle; Cashwell, Leah; Prajerova, Kveta; Bunn, Jennifer

    2018-04-01

    The prone bridge maneuver, or plank, has been viewed as a potential alternative to curl-ups for assessing trunk muscle performance. The purpose of this study was to assess prone bridge test performance, validity, and reliability among younger and older adults. Sixty younger (20-35 years old) and 60 older (60-79 years old) participants completed this study. Groups were evenly divided by sex. Participants completed surveys regarding physical activity and abdominal exercise participation. Height, weight, body mass index (BMI), and waist circumference were measured. On two occasions, 5-9 days apart, participants held a prone bridge until volitional exhaustion or until repeated technique failure. Validity was examined using data from the first session: convergent validity by calculating correlations between survey responses, anthropometrics, and prone bridge time, known groups validity by using an ANOVA comparing bridge times of younger and older adults and of men and women. Test-retest reliability was examined by using a paired t-test to compare prone bridge times for Session1 and Session 2. Furthermore, an intraclass correlation coefficient (ICC) was used to characterize relative reliability and minimal detectable change (MDC 95% ) was used to describe absolute reliability. The mean prone bridge time was 145.3 ± 71.5 s, and was positively correlated with physical activity participation (p ≤ 0.001) and negatively correlated with BMI and waist circumference (p ≤ 0.003). Younger participants had significantly longer plank times than older participants (p = 0.003). The ICC between testing sessions was 0.915. The prone bridge test is a valid and reliable measure for evaluating abdominal performance in both younger and older adults. Copyright © 2017 Elsevier Ltd. All rights reserved.

  13. Analysis of Hypodermic Needles and Syringes for the Presence of Blood and Polydimethylsiloxane (Silicone) Utilizing Microchemical Tests and Infrared Spectroscopy.

    PubMed

    Crowe, John B; Lanzarotta, Adam; Witkowski, Mark R; Andria, Sara E

    2015-07-01

    Suspect hypodermic needles and syringes were seized from an unlicensed individual who was allegedly injecting patients with silicone (polydimethylsiloxane [PDMS]) for cosmetic enhancement. Since control syringe barrels and needles often contain an interfering PDMS lubricant, a risk for false positives of foreign PDMS exists. The focus of this report was to minimize this risk and determine a quick and reliable test for the presence of blood in PDMS matrices. Using ATR-FT-IR spectroscopy, the risk for false-positive identification of foreign PDMS was reduced by (i) overfilling the sampling aperture to prevent spectral distortions and (ii) sampling a region of the suspect syringe/needle assembly where manufacturer-applied PDMS is not typically located. Analysis for blood indicated that the Teichman microchemical test was effective for detecting blood in the presence of PDMS. Overall, detecting PDMS established intent and detecting blood established that the needle containing the PDMS had been used for injection. Published 2015. This article is a U.S. Government work and is in the public domain in the USA.

  14. Oligometastatic prostate cancer: shaping the definition with molecular imaging and an improved understanding of tumor biology.

    PubMed

    Joice, Gregory A; Rowe, Steven P; Pienta, Kenneth J; Gorin, Michael A

    2017-11-01

    The aim of this review is to discuss how novel imaging modalities and molecular markers are shaping the definition of oligometastatic prostate cancer. To effectively classify a patient as having oligometastatic prostate cancer, diagnostic tests must be sensitive enough to detect subtle sites of metastatic disease. Conventional imaging modalities can readily detect widespread polymetastatic disease but do not have the sensitivity necessary to reliably classify patients as oligometastatic. Molecular imaging using both metabolic- and molecularly-targeted radiotracers has demonstrated great promise in aiding in our ability to define the oligometastatic state. Perhaps the most promising data to date have been generated with radiotracers targeting prostate-specific membrane antigen. In addition, early studies are beginning to define biologic markers in the oligometastatic state that may be indicative of disease with minimal metastatic potential. Recent developments in molecular imaging have allowed for improved detection of metastatic prostate cancer allowing for more accurate staging of patients with oligometastatic disease. Future development of biologic markers may assist in defining the oligometastatic state and determining prognosis.

  15. Nocturnal continuous glucose monitoring: accuracy and reliability of hypoglycemia detection in patients with type 1 diabetes at high risk of severe hypoglycemia.

    PubMed

    Bay, Christiane; Kristensen, Peter Lommer; Pedersen-Bjergaard, Ulrik; Tarnow, Lise; Thorsteinsson, Birger

    2013-05-01

    A reliable method to detect biochemical nocturnal hypoglycemia is highly needed, especially in patients with recurrent severe hypoglycemia. We evaluated reliability of nocturnal continuous glucose monitoring (CGM) in patients with type 1 diabetes at high risk of severe hypoglycemia. Seventy-two type 1 diabetes patients with recurrent severe hypoglycemia (two or more events within the last year) participated for 4 nights in blinded CGM recordings (Guardian(®) REAL-Time CGMS and Sof-Sensor(®); Medtronic MiniMed, Northridge, CA). Blood was drawn hourly from 23:00 to 07:00 h for plasma glucose (PG) measurements (gold standard). Valid data were obtained in 217 nights. The sensitivity of CGM was 65% (95% confidence interval, 53-77%) below 4 mmol/L, 40% (24-56%) below 3 mmol/L, and 17% (0-47%) below 2.2 mmol/L. PG and CGM readings correlated in the total measurement range (Spearman's ρ=0.82; P<0.001). In the normo- and hyperglycemic ranges CGM underestimated PG by 1.1 mmol/L (0.9-1.2 mmol/L) (P<0.001); in contrast, in the hypoglycemic range (PG<4 mmol/L) CGM overestimated PG levels by 1.0 mmol/L (P<0.001). The mean absolute relative differences in the hypo- (≤3.9 mmol/L), normo- (4-9.9 mmol/L), and hyperglycemic (≥10 mmol/L) ranges were 45% (37-53%), 23% (22-25%), and 20% (19-21%), respectively. Continuous glucose error grid analysis indicated a clinical accuracy of 56%, 99%, and 93% in the hypo-, normo-, and hyperglycemic ranges, respectively. The accuracy in the hypoglycemic range of nocturnal CGM data using Sof-Sensor is suboptimal in type 1 diabetes patients at high risk of severe hypoglycemia. To ensure clinical useful sensitivity in detection of nocturnal hypoglycemic episodes, an alarm threshold should not be lower than 4 mmol/L.

  16. Validity and reliability of the Nintendo Wii Balance Board to assess standing balance and sensory integration in highly functional older adults.

    PubMed

    Scaglioni-Solano, Pietro; Aragón-Vargas, Luis F

    2014-06-01

    Standing balance is an important motor task. Postural instability associated with age typically arises from deterioration of peripheral sensory systems. The modified Clinical Test of Sensory Integration for Balance and the Tandem test have been used to screen for balance. Timed tests present some limitations, whereas quantification of the motions of the center of pressure (CoP) with portable and inexpensive equipment may help to improve the sensitivity of these tests and give the possibility of widespread use. This study determines the validity and reliability of the Wii Balance Board (Wii BB) to quantify CoP motions during the mentioned tests. Thirty-seven older adults completed three repetitions of five balance conditions: eyes open, eyes closed, eyes open on a compliant surface, eyes closed on a compliant surface, and tandem stance, all performed on a force plate and a Wii BB simultaneously. Twenty participants repeated the trials for reliability purposes. CoP displacement was the main outcome measure. Regression analysis indicated that the Wii BB has excellent concurrent validity, and Bland-Altman plots showed good agreement between devices with small mean differences and no relationship between the difference and the mean. Intraclass correlation coefficients (ICCs) indicated modest-to-excellent test-retest reliability (ICC=0.64-0.85). Standard error of measurement and minimal detectable change were similar for both devices, except the 'eyes closed' condition, with greater standard error of measurement for the Wii BB. In conclusion, the Wii BB is shown to be a valid and reliable method to quantify CoP displacement in older adults.

  17. THE RELIABILITY AND CONCURRENT VALIDITY OF MEASUREMENTS USED TO QUANTIFY LUMBAR SPINE MOBILITY: AN ANALYSIS OF AN IPHONE® APPLICATION AND GRAVITY BASED INCLINOMETRY

    PubMed Central

    Pizzini, Matias; Robinson, Ashley; Yanez, Dania; Hanney, William J.

    2013-01-01

    Purpose/Aim: This purpose of this study was to investigate the reliability, minimal detectable change (MDC), and concurrent validity of active spinal mobility measurements using a gravity‐based bubble inclinometer and iPhone® application. Materials/Methods: Two investigators each used a bubble inclinometer and an iPhone® with inclinometer application to measure total thoracolumbo‐pelvic flexion, isolated lumbar flexion, total thoracolumbo‐pelvic extension, and thoracolumbar lateral flexion in 30 asymptomatic participants using a blinded repeated measures design. Results: The procedures used in this investigation for measuring spinal mobility yielded good intrarater and interrater reliability with Intraclass Correlation Coefficients (ICC) for bubble inclinometry ≥ 0.81 and the iPhone® ≥ 0.80. The MDC90 for the interrater analysis ranged from 4° to 9°. The concurrent validity between bubble inclinometry and the iPhone® application was good with ICC values of ≥ 0.86. The 95% level of agreement indicates that although these measuring instruments are equivalent individual differences of up to 18° may exist when using these devices interchangeably. Conclusions: The bubble inclinometer and iPhone® possess good intrarater and interrater reliability as well as concurrent validity when strict measurement procedures are adhered to. This study provides preliminary evidence to suggest that smart phone applications may offer clinical utility comparable to inclinometry for quantifying spinal mobility. Clinicians should be aware of the potential disagreement when using these devices interchangeably. Level of Evidence: 2b (Observational study of reliability) PMID:23593551

  18. The reliability and concurrent validity of measurements used to quantify lumbar spine mobility: an analysis of an iphone® application and gravity based inclinometry.

    PubMed

    Kolber, Morey J; Pizzini, Matias; Robinson, Ashley; Yanez, Dania; Hanney, William J

    2013-04-01

    PURPOSEAIM: This purpose of this study was to investigate the reliability, minimal detectable change (MDC), and concurrent validity of active spinal mobility measurements using a gravity-based bubble inclinometer and iPhone® application. MATERIALSMETHODS: Two investigators each used a bubble inclinometer and an iPhone® with inclinometer application to measure total thoracolumbo-pelvic flexion, isolated lumbar flexion, total thoracolumbo-pelvic extension, and thoracolumbar lateral flexion in 30 asymptomatic participants using a blinded repeated measures design. The procedures used in this investigation for measuring spinal mobility yielded good intrarater and interrater reliability with Intraclass Correlation Coefficients (ICC) for bubble inclinometry ≥ 0.81 and the iPhone® ≥ 0.80. The MDC90 for the interrater analysis ranged from 4° to 9°. The concurrent validity between bubble inclinometry and the iPhone® application was good with ICC values of ≥ 0.86. The 95% level of agreement indicates that although these measuring instruments are equivalent individual differences of up to 18° may exist when using these devices interchangeably. The bubble inclinometer and iPhone® possess good intrarater and interrater reliability as well as concurrent validity when strict measurement procedures are adhered to. This study provides preliminary evidence to suggest that smart phone applications may offer clinical utility comparable to inclinometry for quantifying spinal mobility. Clinicians should be aware of the potential disagreement when using these devices interchangeably. 2b (Observational study of reliability).

  19. Shuttle swimming test in young water polo players: reliability, responsiveness and age-related value.

    PubMed

    Melchiorri, Giovanni; Viero, Valerio; Triossi, Tamara; Padua, Elvira; Bonifazi, Marco

    2017-11-01

    This study investigated the applicability of a sport-specific test, the Shuttle Swim Test, in young water polo players to measure RSA. The aims were: to assess the reliability and to measure the responsiveness of the SST in young water polo athletes, and to provide age-related values of SST. Three hundred thirty-three elite athletes (18.3±5.1 years) were involved in the study. Of these, 99 were young people under 13 (13.1±0.5 years) who also underwent measurements for reliability and responsiveness of the SST The following six measures was used to assess anthropometric characteristics of the sample: height, weight, chest circumference, hip circumference, waist circumference, and arm span. Two performance measures were performed on dry land: push up and chin up. Reliability and responsiveness were measured by comparing the average speed of two trials: SST1 was 1.48±0.13 m·s-1 and SST2 1.47±.12 m·s-1. The SST showed good reliability in younger athletes (r=0.96). The Minimal Detectable Change is 0.06 m·s-1 (6 seconds of the total time) which corresponds to 3.6% of the average value measured, confirming the good responsiveness of the test. Coaches and researchers can use this value in the interpretation of the SST test results: changes below these values could be related to a measurement error. The various age-related values reported may help technicians to better interpret the performance of their athletes during competition.

  20. Intelligent Approaches in Improving In-vehicle Network Architecture and Minimizing Power Consumption in Combat Vehicles

    DTIC Science & Technology

    2011-01-01

    4 . TITLE AND SUBTITLE INTELLIGENT APPROACHES IN IMPROVING IN-VEHICLE NETWORK ARCHITECTURE AND MINIMIZING POWER CONSUMPTION IN COMBAT VEHICLES 5a... 4 1.3 Organization...32 CHAPTER 4 – SOFTWARE RELIABILITY PREDICTION FOR COMBAT VEHICLES . 33 4.1 Introduction

  1. The Applicability of Standard Error of Measurement and Minimal Detectable Change to Motor Learning Research-A Behavioral Study.

    PubMed

    Furlan, Leonardo; Sterr, Annette

    2018-01-01

    Motor learning studies face the challenge of differentiating between real changes in performance and random measurement error. While the traditional p -value-based analyses of difference (e.g., t -tests, ANOVAs) provide information on the statistical significance of a reported change in performance scores, they do not inform as to the likely cause or origin of that change, that is, the contribution of both real modifications in performance and random measurement error to the reported change. One way of differentiating between real change and random measurement error is through the utilization of the statistics of standard error of measurement (SEM) and minimal detectable change (MDC). SEM is estimated from the standard deviation of a sample of scores at baseline and a test-retest reliability index of the measurement instrument or test employed. MDC, in turn, is estimated from SEM and a degree of confidence, usually 95%. The MDC value might be regarded as the minimum amount of change that needs to be observed for it to be considered a real change, or a change to which the contribution of real modifications in performance is likely to be greater than that of random measurement error. A computer-based motor task was designed to illustrate the applicability of SEM and MDC to motor learning research. Two studies were conducted with healthy participants. Study 1 assessed the test-retest reliability of the task and Study 2 consisted in a typical motor learning study, where participants practiced the task for five consecutive days. In Study 2, the data were analyzed with a traditional p -value-based analysis of difference (ANOVA) and also with SEM and MDC. The findings showed good test-retest reliability for the task and that the p -value-based analysis alone identified statistically significant improvements in performance over time even when the observed changes could in fact have been smaller than the MDC and thereby caused mostly by random measurement error, as opposed to by learning. We suggest therefore that motor learning studies could complement their p -value-based analyses of difference with statistics such as SEM and MDC in order to inform as to the likely cause or origin of any reported changes in performance.

  2. Reliability of the "Ten Test" for assessment of discriminative sensation in hand trauma.

    PubMed

    Berger, Michael J; Regan, William R; Seal, Alex; Bristol, Sean G

    2016-10-01

    "Ten Test" (TT) is a bedside measure of discriminative sensation, whereby the magnitude of abnormal sensation to moving light touch is normalized to an area of normal sensation on an 11-point Likert scale (0-10). The purposes of this study were to determine reliability parameters of the TT in a cohort of patients presenting to a hand trauma clinic with subjectively altered sensation post-injury and to compare the reliability of TT to that of the Weinstein Enhanced Sensory Test (WEST). Study participants (n = 29, mean age = 37 ± 12) comprised patients presenting to an outpatient hand trauma clinic with recent hand trauma and self reported abnormal sensation. Participants underwent TT and WEST by two separate raters on the same day. Interrater reliability, response stability and responsiveness of each test were determined by the intraclass correlation coefficient (ICC: 2, 1), standard error of measurement (SEM) with 95% confidence intervals (CI) and minimal detectable difference score, with 95% CI (MDD95), respectively. The TT displayed excellent interrater reliability (ICC = 0.95, 95% CI 0.89-0.97) compared to good reliability for WEST (ICC = 0.78, 95% CI 0.58-0.89). The range of true scores expected with 95% confidence based on the SEM (i.e. response stability), was ±1.1 for TT and ±1.1 for WEST. MDD95 scores reflecting test responsiveness were 1.5 and 1.6 for TT and WEST, respectively. The TT displayed excellent reliability parameters in this patient population. Reliability parameters were stronger for TT compared to WEST. These results provide support for the use of TT as a component of the sensory exam in hand trauma. Copyright © 2016 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  3. Aerospace reliability applied to biomedicine.

    NASA Technical Reports Server (NTRS)

    Lalli, V. R.; Vargo, D. J.

    1972-01-01

    An analysis is presented that indicates that the reliability and quality assurance methodology selected by NASA to minimize failures in aerospace equipment can be applied directly to biomedical devices to improve hospital equipment reliability. The Space Electric Rocket Test project is used as an example of NASA application of reliability and quality assurance (R&QA) methods. By analogy a comparison is made to show how these same methods can be used in the development of transducers, instrumentation, and complex systems for use in medicine.

  4. Reliability of Achilles Tendon Moment Arm Measured In Vivo Using Freehand Three-Dimensional Ultrasound.

    PubMed

    Obst, Steven J; Barber, Lee; Miller, Ashton; Barrett, Rod S

    2017-08-01

    This study investigated reliability of freehand three-dimensional ultrasound (3DUS) measurement of in vivo human Achilles tendon (AT) moment arm. Sixteen healthy adults were scanned on 2 separate occasions by a single investigator. 3DUS scans were performed over the free AT, medial malleolus, and lateral malleolus with the ankle passively positioned in maximal dorsiflexion, mid dorsiflexion, neutral, mid plantar flexion and maximal plantar flexion. 3D reconstructions of the AT, medial malleolus, and lateral malleolus were created from manual segmentation of the ultrasound images and used to geometrically determine the AT moment arm using both a straight (straight AT MA ) and curved (curved AT MA ) tendon line-of-action. Both methods were reliable within- and between-session (intra-class correlation coefficients > 0.92; coefficient of variation < 2.5 %) and revealed that AT moment arm increased by ∼ 7 mm from maximal dorsiflexion (∼ 41mm) to maximal plantar flexion (∼ 48 mm). Failing to account for tendon curvature led to a small overestimation (< 2 mm) of AT moment arm that was most pronounced in ankle plantar flexion, but was less than the minimal detectable change of the method and could be disregarded.

  5. A new approach to determining net impulse and identification of its characteristics in countermovement jumping: reliability and validity.

    PubMed

    Mizuguchi, Satoshi; Sands, William A; Wassinger, Craig A; Lamont, Hugh S; Stone, Michael H

    2015-06-01

    Examining a countermovement jump (CMJ) force-time curve related to net impulse might be useful in monitoring athletes' performance. This study aimed to investigate the reliability of alternative net impulse calculation and net impulse characteristics (height, width, rate of force development, shape factor, and proportion) and validate against the traditional calculation in the CMJ. Twelve participants performed the CMJ in two sessions (48 hours apart) for test-retest reliability. Twenty participants were involved for the validity assessment. Results indicated intra-class correlation coefficient (ICC) of ≥ 0.89 and coefficient of variation (CV) of ≤ 5.1% for all of the variables except for rate of force development (ICC = 0.78 and CV = 22.3%). The relationship between the criterion and alternative calculations was r = 1.00. While the difference between them was statistically significant (245.96 ± 63.83 vs. 247.14 ± 64.08 N s, p < 0.0001), the effect size was trivial and deemed practically minimal (d = 0.02). In conclusion, variability of rate of force development will pose a greater challenge in detecting performance changes. Also, the alternative calculation can be used practically in place of the traditional calculation to identify net impulse characteristics and monitor and study athletes' performance in greater depth.

  6. [THE COMPARISON OF RESULTS OF DETECTION OF MINIMAL RESIDUAL DISEASE IN PERIPHERAL BLOOD AND MARROW IN CHILDREN OF THE FIRST YEAR OF LIFE WITH ACUTE LYMPHOBLASTIC LEUCOSIS].

    PubMed

    Tsaur, G A; Riger, T O; Popov, A M; Nasedkina, T V; Kustanovich, A M; Solodovnikov, A G; Streneva, O V; Shorikov, E V; Tsvirenko, S V; Saveliev, L I; Fechina, L G

    2015-04-01

    The occurrence of minimal residual disease is an important prognostic factor under acute lymphoblastic leucosis in children and adults. In overwhelming majority of research studies bone marrow is used to detect minimal residual disease. The comparative characteristic of detection of minimal residual disease in peripheral blood and bone marrow was carried out. The prognostic role of occurrence of minimal residual disease in peripheral blood and bone marrow under therapy according protocol MLL-Baby was evaluated. The analysis embraced 142 pair samples from 53 patients with acute lymphoblastic leucosis and various displacements of gene MLL younger than 365 days. The minimal residual disease was detected by force of identification of chimeric transcripts using polymerase chain reaction in real-time mode in 7 sequential points of observation established by protocol of therapy. The comparability of results of qualitative detection of minimal residual disease in bone marrow and peripheral blood amounted to 84.5%. At that, in all 22 (15.5%) discordant samples minimal residual disease was detected only in bone marrow. Despite of high level of comparability of results of detection of minimal residual disease in peripheral blood and bone marrow the occurrence of minimal residual disease in peripheral blood at various stages of therapy demonstrated no independent prognostic significance. The established differences had no relationship with sensitivity of method determined by value of absolute expression of gene ABL. Most likely, these differences reflected real distribution of tumor cells. The results of study demonstrated that application of peripheral blood instead of bone marrow for monitoring of minimal residual disease under acute lymphoblastic leucosis in children of first year of life is inappropriate. At the same time, retention of minimal residual disease in TH4 in bone marrow was an independent and prognostic unfavorable factor under therapy of acute lymphoblastic leucosis of children of first year of life according protocol MLL-Baby (OO=7.326, confidence interval 2.378-22.565).

  7. Girsanov's transformation based variance reduced Monte Carlo simulation schemes for reliability estimation in nonlinear stochastic dynamics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kanjilal, Oindrila, E-mail: oindrila@civil.iisc.ernet.in; Manohar, C.S., E-mail: manohar@civil.iisc.ernet.in

    The study considers the problem of simulation based time variant reliability analysis of nonlinear randomly excited dynamical systems. Attention is focused on importance sampling strategies based on the application of Girsanov's transformation method. Controls which minimize the distance function, as in the first order reliability method (FORM), are shown to minimize a bound on the sampling variance of the estimator for the probability of failure. Two schemes based on the application of calculus of variations for selecting control signals are proposed: the first obtains the control force as the solution of a two-point nonlinear boundary value problem, and, the secondmore » explores the application of the Volterra series in characterizing the controls. The relative merits of these schemes, vis-à-vis the method based on ideas from the FORM, are discussed. Illustrative examples, involving archetypal single degree of freedom (dof) nonlinear oscillators, and a multi-degree of freedom nonlinear dynamical system, are presented. The credentials of the proposed procedures are established by comparing the solutions with pertinent results from direct Monte Carlo simulations. - Highlights: • The distance minimizing control forces minimize a bound on the sampling variance. • Establishing Girsanov controls via solution of a two-point boundary value problem. • Girsanov controls via Volterra's series representation for the transfer functions.« less

  8. Analysis of free amino acids in Amur sturgeon by ultra-performance liquid chromatography using pre-column derivatization with 6-aminoquinolyl-carbamyl.

    PubMed

    Sun, Yanchun; Xu, Xianzhu; Mou, Zhenbo; Wang, Jing; Tan, Zhijun; Wu, Song

    2012-12-01

    A rapid, sensitive, and reliable ultra-performance liquid chromatography (UPLC) coupled with photodiode array detection method was developed for the amino acid analysis of Amur sturgeon (Acipenser schrenckii Brandt). The method uses minimal sample volume and automated online precolumn derivitization of amino acids with fluorescent 6-aminoquinolyl-carbamyl reagent. The chromatographic separation was achieved by UPLC, which used a column with 1.7 μm particle packing that enabled higher speed of analysis, peak capacity, greater resolution, and increased sensitivity. Amino acid derivatives obtained under optimal conditions were separated on a Waters UPLC BEH C(18) column with Acetonitrile-acetate buffer as mobile phase. Matrix effects were investigated and good linearities with correlation coefficients better than 0.9949 were obtained over a wide range of 5-1000 μmol/L for all amino acids. The simple sample preparation and minimal sample volume make the method useful for the quantitation of 17 amino acids in Amur sturgeon samples. It is concluded that a rapid and robust platform based on UPLC was established, and a total of 17 amino acids of Amur sturgeon were tentatively detected. This method showed good accuracy and repeatability that can be used for the quantification of amino acids in real samples. © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  9. Fast methodology for the reliable determination of nonylphenol in water samples by minimal labeling isotope dilution mass spectrometry.

    PubMed

    Fabregat-Cabello, Neus; Castillo, Ángel; Sancho, Juan V; González, Florenci V; Roig-Navarro, Antoni Francesc

    2013-08-02

    In this work we have developed and validated an accurate and fast methodology for the determination of 4-nonylphenol (technical mixture) in complex matrix water samples by UHPLC-ESI-MS/MS. The procedure is based on isotope dilution mass spectrometry (IDMS) in combination with isotope pattern deconvolution (IPD), which provides the concentration of the analyte directly from the spiked sample without requiring any methodological calibration graph. To avoid any possible isotopic effect during the analytical procedure the in-house synthesized (13)C1-4-(3,6-dimethyl-3-heptyl)phenol was used as labeled compound. This proposed surrogate was able to compensate the matrix effect even from wastewater samples. A SPE pre-concentration step together with exhaustive efforts to avoid contamination were included to reach the signal-to-noise ratio necessary to detect the endogenous concentrations present in environmental samples. Calculations were performed acquiring only three transitions, achieving limits of detection lower than 100ng/g for all water matrix assayed. Recoveries within 83-108% and coefficients of variation ranging from 1.5% to 9% were obtained. On the contrary a considerable overestimation was obtained with the most usual classical calibration procedure using 4-n-nonylphenol as internal standard, demonstrating the suitability of the minimal labeling approach. Copyright © 2013 Elsevier B.V. All rights reserved.

  10. Using minimal spanning trees to compare the reliability of network topologies

    NASA Technical Reports Server (NTRS)

    Leister, Karen J.; White, Allan L.; Hayhurst, Kelly J.

    1990-01-01

    Graph theoretic methods are applied to compute the reliability for several types of networks of moderate size. The graph theory methods used are minimal spanning trees for networks with bi-directional links and the related concept of strongly connected directed graphs for networks with uni-directional links. A comparison is conducted of ring networks and braided networks. The case is covered where just the links fail and the case where both links and nodes fail. Two different failure modes for the links are considered. For one failure mode, the link no longer carries messages. For the other failure mode, the link delivers incorrect messages. There is a description and comparison of link-redundancy versus path-redundancy as methods to achieve reliability. All the computations are carried out by means of a fault tree program.

  11. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Carlson, J.J.; Bouchard, A.M.; Osbourn, G.C.

    Future generation automated human biometric identification and verification will require multiple features/sensors together with internal and external information sources to achieve high performance, accuracy, and reliability in uncontrolled environments. The primary objective of the proposed research is to develop a theoretical and practical basis for identifying and verifying people using standoff biometric features that can be obtained with minimal inconvenience during the verification process. The basic problem involves selecting sensors and discovering features that provide sufficient information to reliably verify a person`s identity under the uncertainties caused by measurement errors and tactics of uncooperative subjects. A system was developed formore » discovering hand, face, ear, and voice features and fusing them to verify the identity of people. The system obtains its robustness and reliability by fusing many coarse and easily measured features into a near minimal probability of error decision algorithm.« less

  12. Beam Walking in Special Education

    ERIC Educational Resources Information Center

    Broadhead, Geoffrey D.

    1974-01-01

    An experimental test on beam walking (for balance), administered to 189 minimally brain injured and 226 educable mentally retarded (EMR) 8- to 13-year-old children, yielded results such as reliability estimates for the mean of three trials were high and there was greater performance reliability for EMR children. (MC)

  13. Structural Optimization for Reliability Using Nonlinear Goal Programming

    NASA Technical Reports Server (NTRS)

    El-Sayed, Mohamed E.

    1999-01-01

    This report details the development of a reliability based multi-objective design tool for solving structural optimization problems. Based on two different optimization techniques, namely sequential unconstrained minimization and nonlinear goal programming, the developed design method has the capability to take into account the effects of variability on the proposed design through a user specified reliability design criterion. In its sequential unconstrained minimization mode, the developed design tool uses a composite objective function, in conjunction with weight ordered design objectives, in order to take into account conflicting and multiple design criteria. Multiple design criteria of interest including structural weight, load induced stress and deflection, and mechanical reliability. The nonlinear goal programming mode, on the other hand, provides for a design method that eliminates the difficulty of having to define an objective function and constraints, while at the same time has the capability of handling rank ordered design objectives or goals. For simulation purposes the design of a pressure vessel cover plate was undertaken as a test bed for the newly developed design tool. The formulation of this structural optimization problem into sequential unconstrained minimization and goal programming form is presented. The resulting optimization problem was solved using: (i) the linear extended interior penalty function method algorithm; and (ii) Powell's conjugate directions method. Both single and multi-objective numerical test cases are included demonstrating the design tool's capabilities as it applies to this design problem.

  14. Failure Modes Effects and Criticality Analysis, an Underutilized Safety, Reliability, Project Management and Systems Engineering Tool

    NASA Astrophysics Data System (ADS)

    Mullin, Daniel Richard

    2013-09-01

    The majority of space programs whether manned or unmanned for science or exploration require that a Failure Modes Effects and Criticality Analysis (FMECA) be performed as part of their safety and reliability activities. This comes as no surprise given that FMECAs have been an integral part of the reliability engineer's toolkit since the 1950s. The reasons for performing a FMECA are well known including fleshing out system single point failures, system hazards and critical components and functions. However, in the author's ten years' experience as a space systems safety and reliability engineer, findings demonstrate that the FMECA is often performed as an afterthought, simply to meet contract deliverable requirements and is often started long after the system requirements allocation and preliminary design have been completed. There are also important qualitative and quantitative components often missing which can provide useful data to all of project stakeholders. These include; probability of occurrence, probability of detection, time to effect and time to detect and, finally, the Risk Priority Number. This is unfortunate as the FMECA is a powerful system design tool that when used effectively, can help optimize system function while minimizing the risk of failure. When performed as early as possible in conjunction with writing the top level system requirements, the FMECA can provide instant feedback on the viability of the requirements while providing a valuable sanity check early in the design process. It can indicate which areas of the system will require redundancy and which areas are inherently the most risky from the onset. Based on historical and practical examples, it is this author's contention that FMECAs are an immense source of important information for all involved stakeholders in a given project and can provide several benefits including, efficient project management with respect to cost and schedule, system engineering and requirements management, assembly integration and test (AI&T) and operations if applied early, performed to completion and updated along with system design.

  15. A heat-pulse flowmeter for measuring minimal discharge rates in boreholes

    USGS Publications Warehouse

    Hess, A.E.

    1982-01-01

    The U.S. Geological Survey has tested a borehole-configured heat-pulse flowmeter which has good low-velocity flow-measuring sensitivity. The flowmeter was tested in the laboratory in 51-, 102-, and 152-millimeter-diameter columns using water velocities ranging from 0.35 to 250 millimeters per second. The heat-pulse flowmeter also was tested in a 15-meter-deep granite test pit with controlled water flow, and in a 58-meter-deep borehole in sedimentary materials. The flowmeter's capability to detect and measure naturally occurring, low-velocity, thermally induced convection currents in boreholes was demonstrated. Further improvements to the heat-pulse-flowmeter system are needed to increase its reliability and improve its response through four-conductor logging cable.

  16. Smart ECG Monitoring Patch with Built-in R-Peak Detection for Long-Term HRV Analysis.

    PubMed

    Lee, W K; Yoon, H; Park, K S

    2016-07-01

    Since heart rate variability (HRV) analysis is widely used to evaluate the physiological status of the human body, devices specifically designed for such applications are needed. To this end, we developed a smart electrocardiography (ECG) patch. The smart patch measures ECG using three electrodes integrated into the patch, filters the measured signals to minimize noise, performs analog-to-digital conversion, and detects R-peaks. The measured raw ECG data and the interval between the detected R-peaks can be recorded to enable long-term HRV analysis. Experiments were performed to evaluate the performance of the built-in R-wave detection, robustness of the device under motion, and applicability to the evaluation of mental stress. The R-peak detection results obtained with the device exhibited a sensitivity of 99.29%, a positive predictive value of 100.00%, and an error of 0.71%. The device also exhibited less motional noise than conventional ECG recording, being stable up to a walking speed of 5 km/h. When applied to mental stress analysis, the device evaluated the variation in HRV parameters in the same way as a normal ECG, with very little difference. This device can help users better understand their state of health and provide physicians with more reliable data for objective diagnosis.

  17. Network capability estimation. Vela network evaluation and automatic processing research. Technical report. [NETWORTH

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Snell, N.S.

    1976-09-24

    NETWORTH is a computer program which calculates the detection and location capability of seismic networks. A modified version of NETWORTH has been developed. This program has been used to evaluate the effect of station 'downtime', the signal amplitude variance, and the station detection threshold upon network detection capability. In this version all parameters may be changed separately for individual stations. The capability of using signal amplitude corrections has been added. The function of amplitude corrections is to remove possible bias in the magnitude estimate due to inhomogeneous signal attenuation. These corrections may be applied to individual stations, individual epicenters, ormore » individual station/epicenter combinations. An option has been added to calculate the effect of station 'downtime' upon network capability. This study indicates that, if capability loss due to detection errors can be minimized, then station detection threshold and station reliability will be the fundamental limits to network performance. A baseline network of thirteen stations has been performed. These stations are as follows: Alaskan Long Period Array, (ALPA); Ankara, (ANK); Chiang Mai, (CHG); Korean Seismic Research Station, (KSRS); Large Aperture Seismic Array, (LASA); Mashhad, (MSH); Mundaring, (MUN); Norwegian Seismic Array, (NORSAR); New Delhi, (NWDEL); Red Knife, Ontario, (RK-ON); Shillong, (SHL); Taipei, (TAP); and White Horse, Yukon, (WH-YK).« less

  18. Technical principles of direct bipolar electrostimulation for cortical and subcortical mapping in awake craniotomy.

    PubMed

    Pallud, J; Mandonnet, E; Corns, R; Dezamis, E; Parraga, E; Zanello, M; Spena, G

    2017-06-01

    Intraoperative application of electrical current to the brain is a standard technique during brain surgery for inferring the function of the underlying brain. The purpose of intraoperative functional mapping is to reliably identify cortical areas and subcortical pathways involved in eloquent functions, especially motor, sensory, language and cognitive functions. The aim of this article is to review the rationale and the electrophysiological principles of the use of direct bipolar electrostimulation for cortical and subcortical mapping under awake conditions. Direct electrical stimulation is a window into the whole functional network that sustains a particular function. It is an accurate (spatial resolution of about 5mm) and a reproducible technique particularly adapted to clinical practice for brain resection in eloquent areas. If the procedure is rigorously applied, the sensitivity of direct electrical stimulation for the detection of cortical and subcortical eloquent areas is nearly 100%. The main disadvantage of this technique is its suboptimal specificity. Another limitation is the identification of eloquent areas during surgery, which, however, could have been functionally compensated postoperatively if removed surgically. Direct electrical stimulation is an easy, accurate, reliable and safe invasive technique for the intraoperative detection of both cortical and subcortical functional brain connectivity for clinical purpose. In our opinion, it is the optimal technique for minimizing the risk of neurological sequelae when resecting in eloquent brain areas. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  19. Optimization of single keV ion implantation for the construction of single P-donor devices

    NASA Astrophysics Data System (ADS)

    Yang, Changyi; Jamieson, David N.; Hopf, Toby; Andresen, Soren E.; Hearne, Sean M.; Hudson, Fay E.; Pakes, Christopher I.; Mitic, Mladen; Gauja, Eric; Tamanyan, Grigori; Dzurak, Andrew S.; Prawer, Steven; Clark, Robert G.

    2005-02-01

    We report recent progress in single keV ion implantation and online detection for the controlled implantation of single donors in silicon. When integrated with silicon nanofabrication technology this forms the "top down" strategy for the construction of prototype solid state quantum computer devices based on phosphorus donors in silicon. We have developed a method of single ion implantation and online registration that employs detector electrodes adjacent to the area into which the donors are to be implanted. The implantation sites are positioned with nanometer accuracy using an electron beam lithography patterned PMMA mask. Control of the implantation depth of 20 nm is achieved by tuning the phosphorus ion energy to 14 keV. The counting of single ion implantation in each site is achieved by the detection of e-/h+ pairs produced by the implanted phosphorus ion in the substrate. The system is calibrated by use of Mn K-line x-rays (5.9 and 6.4 keV) and we find the ionization energy of the 14 keV phosphorus ions in silicon to be about 3.5-4.0 keV for implants through a 5 nm SiO2 surface layer. This paper describes the development of an improved PIN detector structure that provides more reliable performance of the earlier MOS structure. With the new structure, the energy noise threshold has been minimized to 1 keV or less. Unambiguous detection/counting of single keV ion implantation events were achieved with a confidence level greater than 98% with a reliable and reproducible fabrication process.

  20. Robot-Assisted End-Effector-Based Stair Climbing for Cardiopulmonary Exercise Testing: Feasibility, Reliability, and Repeatability.

    PubMed

    Stoller, Oliver; Schindelholz, Matthias; Hunt, Kenneth J

    2016-01-01

    Neurological impairments can limit the implementation of conventional cardiopulmonary exercise testing (CPET) and cardiovascular training strategies. A promising approach to provoke cardiovascular stress while facilitating task-specific exercise in people with disabilities is feedback-controlled robot-assisted end-effector-based stair climbing (RASC). The aim of this study was to evaluate the feasibility, reliability, and repeatability of augmented RASC-based CPET in able-bodied subjects, with a view towards future research and applications in neurologically impaired populations. Twenty able-bodied subjects performed a familiarisation session and 2 consecutive incremental CPETs using augmented RASC. Outcome measures focussed on standard cardiopulmonary performance parameters and on accuracy of work rate tracking (RMSEP-root mean square error). Criteria for feasibility were cardiopulmonary responsiveness and technical implementation. Relative and absolute test-retest reliability were assessed by intraclass correlation coefficients (ICC), standard error of the measurement (SEM), and minimal detectable change (MDC). Mean differences, limits of agreement, and coefficients of variation (CoV) were estimated to assess repeatability. All criteria for feasibility were achieved. Mean V'O2peak was 106±9% of predicted V'O2max and mean HRpeak was 99±3% of predicted HRmax. 95% of the subjects achieved at least 1 criterion for V'O2max, and the detection of the sub-maximal ventilatory thresholds was successful (ventilatory anaerobic threshold 100%, respiratory compensation point 90% of the subjects). Excellent reliability was found for peak cardiopulmonary outcome measures (ICC ≥ 0.890, SEM ≤ 0.60%, MDC ≤ 1.67%). Repeatability for the primary outcomes was good (CoV ≤ 0.12). RASC-based CPET with feedback-guided exercise intensity demonstrated comparable or higher peak cardiopulmonary performance variables relative to predicted values, achieved the criteria for V'O2max, and allowed determination of sub-maximal ventilatory thresholds. The reliability and repeatability were found to be high. There is potential for augmented RASC to be used for exercise testing and prescription in populations with neurological impairments who would benefit from repetitive task-specific training.

  1. Robot-Assisted End-Effector-Based Stair Climbing for Cardiopulmonary Exercise Testing: Feasibility, Reliability, and Repeatability

    PubMed Central

    Stoller, Oliver; Schindelholz, Matthias; Hunt, Kenneth J.

    2016-01-01

    Background Neurological impairments can limit the implementation of conventional cardiopulmonary exercise testing (CPET) and cardiovascular training strategies. A promising approach to provoke cardiovascular stress while facilitating task-specific exercise in people with disabilities is feedback-controlled robot-assisted end-effector-based stair climbing (RASC). The aim of this study was to evaluate the feasibility, reliability, and repeatability of augmented RASC-based CPET in able-bodied subjects, with a view towards future research and applications in neurologically impaired populations. Methods Twenty able-bodied subjects performed a familiarisation session and 2 consecutive incremental CPETs using augmented RASC. Outcome measures focussed on standard cardiopulmonary performance parameters and on accuracy of work rate tracking (RMSEP−root mean square error). Criteria for feasibility were cardiopulmonary responsiveness and technical implementation. Relative and absolute test-retest reliability were assessed by intraclass correlation coefficients (ICC), standard error of the measurement (SEM), and minimal detectable change (MDC). Mean differences, limits of agreement, and coefficients of variation (CoV) were estimated to assess repeatability. Results All criteria for feasibility were achieved. Mean V′O2peak was 106±9% of predicted V′O2max and mean HRpeak was 99±3% of predicted HRmax. 95% of the subjects achieved at least 1 criterion for V′O2max, and the detection of the sub-maximal ventilatory thresholds was successful (ventilatory anaerobic threshold 100%, respiratory compensation point 90% of the subjects). Excellent reliability was found for peak cardiopulmonary outcome measures (ICC ≥ 0.890, SEM ≤ 0.60%, MDC ≤ 1.67%). Repeatability for the primary outcomes was good (CoV ≤ 0.12). Conclusions RASC-based CPET with feedback-guided exercise intensity demonstrated comparable or higher peak cardiopulmonary performance variables relative to predicted values, achieved the criteria for V′O2max, and allowed determination of sub-maximal ventilatory thresholds. The reliability and repeatability were found to be high. There is potential for augmented RASC to be used for exercise testing and prescription in populations with neurological impairments who would benefit from repetitive task-specific training. PMID:26849137

  2. Psychometric properties of the Numeric Pain Rating Scale and Neck Disability Index in patients with cervicogenic headache.

    PubMed

    Young, Ian A; Dunning, James; Butts, Raymond; Cleland, Joshua A; Fernández-de-Las-Peñas, César

    2018-01-01

    Background Self-reported disability and pain intensity are commonly used outcomes in patients with cervicogenic headaches. However, there is a paucity of psychometric evidence to support the use of these self-report outcomes for individuals treated with cervicogenic headaches. Therefore, it is unknown if these measures are reliable, responsive, or result in meaningful clinically important changes in this patient population. Methods A secondary analysis of a randomized clinical trial (n = 110) examining the effects of spinal manipulative therapy with and without exercise in patients with cervicogenic headaches. Reliability, construct validity, responsiveness and thresholds for minimal detectable change and clinically important difference values were calculated for the Neck Disability Index and Numeric Pain Rating Scale. Results The Neck Disability Index exhibited excellent reliability (ICC = 0.92; [95 % CI: 0.46-0.97]), while the Numeric Pain Rating Scale exhibited moderate reliability (ICC = 0.72; [95 % CI: 0.08-0.90]) in the short term. Both instruments also exhibited adequate responsiveness (area under the curve; range = 0.78-0.93) and construct validity ( p < 0.001) in this headache population. Conclusions Both instruments seem well suited as short-term self-report measures for patients with cervicogenic headaches. Clinicians and researchers should expect at least a 2.5-point reduction on the numeric pain rating scale and a 5.5-point reduction on the neck disability index after 4 weeks of intervention to be considered clinically meaningful.

  3. Rapid and reliable determination of illegal adulterant in herbal medicines and dietary supplements by LC/MS/MS.

    PubMed

    Liang, Qionglin; Qu, Jun; Luo, Guoan; Wang, Yiming

    2006-02-13

    In recent years, dietary supplements and herbal medicines are increasing in popularity all over the world. However, it is problematic that some manufacturers illegally included synthetic drugs in their products. Due to the extremely complex matrices of those products, most existing methods for screening illegal adulterations are time-consuming and liable to false positive. In this paper, a robust LC/MS/MS method for the high-throughput, sensitive and reliable determination of illegal adulterations from herbal medicines and dietary supplements was established. Minimal LC separation was employed and MRM was used to simultaneously monitor the three transitions under their respective optimal collision energy for each compound. Positive results were determined only if well-defined peaks appeared at all of the three transitions and the ratios among the peak areas were within given threshold. In this study, the method had been applied for the screening of nine most commonly adulterated therapeutic substances, such as sildenafil (Viagra) and famotidine, and the lower limits of detection of these compounds ranged from 0.05 to 1.5 ng/ml. Little sample preparation was needed for this method and the analysis time was less than 5 min/sample. The reliability has been demonstrated by the test with blank matrix. Over 200 products that were under suspicion by SDA of China had been assayed and till now no false negative or positive result was found. This method is rapid, simple, reliable and capable of screening multiple adulterants in one run.

  4. Silver plating ensures reliable diffusion bonding of dissimilar metals

    NASA Technical Reports Server (NTRS)

    1967-01-01

    Dissimilar metals are reliably joined by diffusion bonding when the surfaces are electroplated with silver. The process involves cleaning and etching, anodization, silver striking, and silver plating with a conventional plating bath. It minimizes the formation of detrimental intermetallic phases and provides greater tolerance of processing parameters.

  5. Reliability, validity and responsiveness of the Spanish Manchester-Oxford Foot Questionnaire (MOXFQ) in patients with foot or ankle surgery.

    PubMed

    Garcés, Juan B Gerstner; Winson, Ian; Goldhahn, Sabine; Castro, Michael D; Swords, Michael P; Grujic, Leslie; Rammelt, Stefan; Sands, Andrew K

    2016-03-01

    The Manchester-Oxford Foot Questionnaire (MOXFQ) has been validated in Spanish for use in patients undergoing foot and ankle surgery. 120 patients completed the MOXFQ and the SF-36 before surgery and 6 and 12 months postoperative. Surgeons completed the American Orthopaedic Foot and Ankle Society (AOFAS) Clinical Rating System. Psychometric properties were assessed for all three MOXFQ dimensions, and for the MOXFQ Index. The Spanish MOXFQ demonstrated consistency with Cronbach's alpha values between 0.65 and 0.90, and reliability ([ICCs] >0.95). It shows a moderate to strong correlation between the Walking/standing dimension and the related domains of the SF-36 (|r|>0.6), the AOFAS Ankle-Hindfoot Scale (|r|>0.47) and Hallux-MTP-IP Scale (|r|>0.64). Responsiveness was excellent, (effect sizes >2.1). The respective minimal detectable change (MDC90) was 14.18 for the MOXFQ Index. The Spanish version of the MOXFQ showed good psychometric properties in patients with foot and ankle disorders. Copyright © 2015 European Foot and Ankle Society. Published by Elsevier Ltd. All rights reserved.

  6. Circulating microRNA Biomarkers as Liquid Biopsy for Cancer Patients: Pros and Cons of Current Assays

    PubMed Central

    Ono, Shigeshi; Lam, Stella; Nagahara, Makoto; Hoon, Dave S. B.

    2015-01-01

    An increasing number of studies have focused on circulating microRNAs (cmiRNA) in cancer patients’ blood for their potential as minimally-invasive biomarkers. Studies have reported the utility of assessing specific miRNAs in blood as diagnostic/prognostic biomarkers; however, the methodologies are not validated or standardized across laboratories. Unfortunately, there is often minimum limited overlap in techniques between results reported even in similar type studies on the same cancer. This hampers interpretation and reliability of cmiRNA as potential cancer biomarkers. Blood collection and processing, cmiRNA extractions, quality and quantity control of assays, defined patient population assessment, reproducibility, and reference standards all affect the cmiRNA assay results. To date, there is no reported definitive method to assess cmiRNAs. Therefore, appropriate and reliable methodologies are highly necessary in order for cmiRNAs to be used in regulated clinical diagnostic laboratories. In this review, we summarize the developments made over the past decade towards cmiRNA detection and discuss the pros and cons of the assays. PMID:26512704

  7. Standard Isotherm Fit Information for Dry CO2 on Sorbents for 4-Bed Molecular Sieve

    NASA Technical Reports Server (NTRS)

    Cmarik, G. E.; Son, K. N.; Knox, J. C.

    2017-01-01

    Onboard the ISS, one of the systems tasked with removal of metabolic carbon dioxide (CO2) is a 4-bed molecular sieve (4BMS) system. In order to enable a 4-person mission to succeed, systems for removal of metabolic CO2 must reliably operate for several years while minimizing power, mass, and volume requirements. This minimization can be achieved through system redesign and/or changes to the separation material(s). A material screening process has identified the most reliable sorbent materials for the next 4BMS. Sorbent characterization will provide the information necessary to guide system design by providing inputs for computer simulations.

  8. Psychometric properties of self-reported questionnaires for the evaluation of symptoms and functional limitations in individuals with rotator cuff disorders: a systematic review.

    PubMed

    St-Pierre, Corinne; Desmeules, François; Dionne, Clermont E; Frémont, Pierre; MacDermid, Joy C; Roy, Jean-Sébastien

    2016-01-01

    To conduct a systematic review of the psychometric properties (reliability, validity and responsiveness) of self-report questionnaires used to assess symptoms and functional limitations of individuals with rotator cuff (RC) disorders. A systematic search in three databases (Cinahl, Medline and Embase) was conducted. Data extraction and critical methodological appraisal were performed independently by three raters using structured tools, and agreement was achieved by consensus. A descriptive synthesis was performed. One-hundred and twenty articles reporting on 11 questionnaires were included. All questionnaires were highly reliable and responsive to change, and showed construct validity; seven questionnaires also shown known-group validity. The minimal detectable change ranged from 6.4% to 20.8% of total score; only two questionnaires (American Shoulder and Elbow Surgeon questionnaire [ASES] and Upper Limb Functional Index [ULFI]) had a measurement error below 10% of global score. Minimal clinically important differences were established for eight questionnaires, and ranged from 8% to 20% of total score. Overall, included questionnaires showed acceptable psychometric properties for individuals with RC disorders. The ASES and ULFI have the smallest absolute error of measurement, while the Western Ontario RC Index is one of the most responsive questionnaires for individuals suffering from RC disorders. All included questionnaires are reliable, valid and responsive for the evaluation of individuals with RC disorders. As all included questionnaires showed good psychometric properties for the targeted population, the choice should be made according to the purpose of the evaluation and to the construct being evaluated by the questionnaire. The WORC, a RC-specific questionnaire, appeared to be more responsive. It should therefore be used to evaluate change in time. If the evaluation is time-limited, shorter questionnaires or short versions should be considered (such as Quick DASH or SST).

  9. NDE detectability of fatigue type cracks in high strength alloys

    NASA Technical Reports Server (NTRS)

    Christner, B. K.; Rummel, W. D.

    1983-01-01

    Specimens suitable for investigating the reliability of production nondestructive evaluation (NDE) to detect tightly closed fatigue cracks in high strength alloys representative of those materials used in spacecraft engine/booster construction were produced. Inconel 718 was selected as representative of nickel base alloys and Haynes 188 was selected as representative of cobalt base alloys used in this application. Cleaning procedures were developed to insure the reusability of the test specimens and a flaw detection reliability assessment of the fluorescent penetrant inspection method was performed using the test specimens produced to characterize their use for future reliability assessments and to provide additional NDE flaw detection reliability data for high strength alloys. The statistical analysis of the fluorescent penetrant inspection data was performed to determine the detection reliabilities for each inspection at a 90% probability/95% confidence level.

  10. Real-time needle guidance with photoacoustic and laser-generated ultrasound probes

    NASA Astrophysics Data System (ADS)

    Colchester, Richard J.; Mosse, Charles A.; Nikitichev, Daniil I.; Zhang, Edward Z.; West, Simeon; Beard, Paul C.; Papakonstantinou, Ioannis; Desjardins, Adrien E.

    2015-03-01

    Detection of tissue structures such as nerves and blood vessels is of critical importance during many needle-based minimally invasive procedures. For instance, unintentional injections into arteries can lead to strokes or cardiotoxicity during interventional pain management procedures that involve injections in the vicinity of nerves. Reliable detection with current external imaging systems remains elusive. Optical generation and reception of ultrasound allow for depth-resolved sensing and they can be performed with optical fibers that are positioned within needles used in clinical practice. The needle probe developed in this study comprised separate optical fibers for generating and receiving ultrasound. Photoacoustic generation of ultrasound was performed on the distal end face of an optical fiber by coating it with an optically absorbing material. Ultrasound reception was performed using a high-finesse Fabry-Pérot cavity. The sensor data was displayed as an M-mode image with a real-time interface. Imaging was performed on a biological tissue phantom.

  11. Frequency Domain Reflectometry Modeling and Measurement for Nondestructive Evaluation of Nuclear Power Plant Cables

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Glass, Samuel W.; Fifield, Leonard S.; Jones, Anthony M.

    Cable insulation polymers are among the more susceptible materials to age-related degradation within a nuclear power plant. This is recognized by both regulators and utilities, so all plants have developed cable aging management programs to detect damage before critical component failure in compliance with regulatory guidelines. Although a wide range of tools are available to evaluate cables and cable systems, cable aging management programs vary in how condition monitoring and NDE is conducted as utilities search for the most reliable and cost-effective ways to assess cable system condition. Frequency domain reflectometry (FDR) is emerging as one valuable tool to locatemore » and assess damaged portions of a cable system with minimal cost and only requires access in most cases to one of the cable terminal ends. This work examines a physics-based model of a cable system and relates it to FDR measurements for a better understanding of specific damage influences on defect detectability.« less

  12. An ultra low power feature extraction and classification system for wearable seizure detection.

    PubMed

    Page, Adam; Pramod Tim Oates, Siddharth; Mohsenin, Tinoosh

    2015-01-01

    In this paper we explore the use of a variety of machine learning algorithms for designing a reliable and low-power, multi-channel EEG feature extractor and classifier for predicting seizures from electroencephalographic data (scalp EEG). Different machine learning classifiers including k-nearest neighbor, support vector machines, naïve Bayes, logistic regression, and neural networks are explored with the goal of maximizing detection accuracy while minimizing power, area, and latency. The input to each machine learning classifier is a 198 feature vector containing 9 features for each of the 22 EEG channels obtained over 1-second windows. All classifiers were able to obtain F1 scores over 80% and onset sensitivity of 100% when tested on 10 patients. Among five different classifiers that were explored, logistic regression (LR) proved to have minimum hardware complexity while providing average F-1 score of 91%. Both ASIC and FPGA implementations of logistic regression are presented and show the smallest area, power consumption, and the lowest latency when compared to the previous work.

  13. Automatic identification of vessel crossovers in retinal images

    NASA Astrophysics Data System (ADS)

    Sánchez, L.; Barreira, N.; Penedo, M. G.; Cancela, B.

    2015-02-01

    Crossovers and bifurcations are interest points of the retinal vascular tree useful to diagnose diseases. Specifically, detecting these interest points and identifying which of them are crossings will give us the opportunity to search for arteriovenous nicking, this is, an alteration of the vessel tree where an artery is crossed by a vein and the former compresses the later. These formations are a clear indicative of hypertension, among other medical problems. There are several studies that have attempted to define an accurate and reliable method to detect and classify these relevant points. In this article, we propose a new method to identify crossovers. Our approach is based on segmenting the vascular tree and analyzing the surrounding area of each interest point. The minimal path between vessel points in this area is computed in order to identify the connected vessel segments and, as a result, to distinguish between bifurcations and crossovers. Our method was tested using retinographies from public databases DRIVE and VICAVR, obtaining an accuracy of 90%.

  14. Simultaneous determination of eight water-soluble vitamins in supplemented foods by liquid chromatography.

    PubMed

    Zafra-Gómez, Alberto; Garballo, Antonio; Morales, Juan C; García-Ayuso, Luis E

    2006-06-28

    A fast, simple, and reliable method for the isolation and determination of the vitamins thiamin, riboflavin, niacin, pantothenic acid, pyridoxine, folic acid, cyanocobalamin, and ascorbic acid in food samples is proposed. The most relevant advantages of the proposed method are the simultaneous determination of the eight more common vitamins in enriched food products and a reduction of the time required for quantitative extraction, because the method consists merely of the addition of a precipitation solution and centrifugation of the sample. Furthermore, this method saves a substantial amount of reagents as compared with official methods, and minimal sample manipulation is achieved due to the few steps required. The chromatographic separation is carried out on a reverse phase C18 column, and the vitamins are detected at different wavelengths by either fluorescence or UV-visible detection. The proposed method was applied to the determination of water-soluble vitamins in supplemented milk, infant nutrition products, and milk powder certified reference material (CRM 421, BCR) with recoveries ranging from 90 to 100%.

  15. Miniature PCR based portable bioaerosol monitor development.

    PubMed

    Agranovski, I E; Usachev, E V; Agranovski, E; Usacheva, O V

    2017-01-01

    A portable bioaerosol monitor is greatly demanded technology in many areas including air quality control, occupational exposure assessment and health risk evaluation, environmental studies and, especially, in defence and bio-terrorism applications. Our recent groundwork allowed us to formulate the concept of a portable bioaerosol monitor, which needs to be light, user friendly, reliable and capable of detecting airborne pathogens within 1-1·5 h on the spot. Conceptually, the event of a bioaerosol concentration burst is determined by triggers to commence the representative air sampling with sequential real-time polymerase chain reaction (PCR) confirmation of the targeted micro-organism present in the air. To minimize reagent consumption and idle running of the technology, an event of a bioaerosol burst is confirmed by three parameters: aerosol particle size, concentration and composition. Only particle sizes above 200 nm attract interest in the bioaerosol. Only an elevated aerosol concentration above the threshold (background aerosol concentration) is a signal to commence the analytical procedure. The combination of our previously developed personal bioaerosol sampler, aerosol particle counter based trigger and portable real-time PCR device formed the basis of the bioaerosol monitoring technology. The portable real-time PCR device was advanced to provide internally controlled detection, significantly reducing false-positive alarms. The technique is capable of detecting selected airborne micro-organisms on the spot within 30-80 min, depending on the genome organization of the particular strain. Due to recent outbreaks of infectious airborne diseases and the continuing threat of intentionally released bioaerosol attacks, investigations into the possibility of the early and reliable detection of pathogenic micro-organisms in the air is becoming increasingly important. The proposed technology consisting of a bioaerosol sampler, technology trigger and PCR device is capable of detecting selected airborne micro-organisms on the spot within a short time period. Journal of Applied Microbiology © 2016 The Society for Applied Microbiology.

  16. Cut set-based risk and reliability analysis for arbitrarily interconnected networks

    DOEpatents

    Wyss, Gregory D.

    2000-01-01

    Method for computing all-terminal reliability for arbitrarily interconnected networks such as the United States public switched telephone network. The method includes an efficient search algorithm to generate minimal cut sets for nonhierarchical networks directly from the network connectivity diagram. Efficiency of the search algorithm stems in part from its basis on only link failures. The method also includes a novel quantification scheme that likewise reduces computational effort associated with assessing network reliability based on traditional risk importance measures. Vast reductions in computational effort are realized since combinatorial expansion and subsequent Boolean reduction steps are eliminated through analysis of network segmentations using a technique of assuming node failures to occur on only one side of a break in the network, and repeating the technique for all minimal cut sets generated with the search algorithm. The method functions equally well for planar and non-planar networks.

  17. A critique of silvicultural approaches to managing defoliating insects in North America

    Treesearch

    R.M. ​Muzika; A.M. Liebhold

    2000-01-01

    A variety of silvicultural techniques have been suggested for managing forest defoliating insects. The objectives focus on minimizing defoliation or minimizing damage from defoliation. The theoretical foundations of many approaches have been built upon observation and correlation, and very little reliable empirical evidence exists to support the objectives of...

  18. Reliability and construct validity of the Spanish version of the 6-item CTS symptoms scale for outcomes assessment in carpal tunnel syndrome.

    PubMed

    Rosales, Roberto S; Martin-Hidalgo, Yolanda; Reboso-Morales, Luis; Atroshi, Isam

    2016-03-03

    The purpose of this study was to assess the reliability and construct validity of the Spanish version of the 6-item carpal tunnel syndrome (CTS) symptoms scale (CTS-6). In this cross-sectional study 40 patients diagnosed with CTS based on clinical and neurophysiologic criteria, completed the standard Spanish versions of the CTS-6 and the disabilities of the arm, shoulder and hand (QuickDASH) scales on two occasions with a 1-week interval. Internal-consistency reliability was assessed with the Cronbach alpha coefficient and test-retest reliability with the intraclass correlation coefficient, two way random effect model and absolute agreement definition (ICC2,1). Cross-sectional precision was analyzed with the Standard Error of the Measurement (SEM). Longitudinal precision for test-retest reliability coefficient was assessed with the Standard Error of the Measurement difference (SEMdiff) and the Minimal Detectable Change at 95 % confidence level (MDC95). For assessing construct validity it was hypothesized that the CTS-6 would have a strong positive correlation with the QuickDASH, analyzed with the Pearson correlation coefficient (r). The standard Spanish version of the CTS-6 presented a Cronbach alpha of 0.81 with a SEM of 0.3. Test-retest reliability showed an ICC of 0.85 with a SRMdiff of 0.36 and a MDC95 of 0.7. The correlation between CTS-6 and the QuickDASH was concordant with the a priori formulated construct hypothesis (r 0.69) CONCLUSIONS: The standard Spanish version of the 6-item CTS symptoms scale showed good internal consistency, test-retest reliability and construct validity for outcomes assessment in CTS. The CTS-6 will be useful to clinicians and researchers in Spanish speaking parts of the world. The use of standardized outcome measures across countries also will facilitate comparison of research results in carpal tunnel syndrome.

  19. Reliability of System Identification Techniques to Assess Standing Balance in Healthy Elderly

    PubMed Central

    Maier, Andrea B.; Aarts, Ronald G. K. M.; van Gerven, Joop M. A.; Arendzen, J. Hans; Schouten, Alfred C.; Meskers, Carel G. M.; van der Kooij, Herman

    2016-01-01

    Objectives System identification techniques have the potential to assess the contribution of the underlying systems involved in standing balance by applying well-known disturbances. We investigated the reliability of standing balance parameters obtained with multivariate closed loop system identification techniques. Methods In twelve healthy elderly balance tests were performed twice a day during three days. Body sway was measured during two minutes of standing with eyes closed and the Balance test Room (BalRoom) was used to apply four disturbances simultaneously: two sensory disturbances, to the proprioceptive and the visual system, and two mechanical disturbances applied at the leg and trunk segment. Using system identification techniques, sensitivity functions of the sensory disturbances and the neuromuscular controller were estimated. Based on the generalizability theory (G theory), systematic errors and sources of variability were assessed using linear mixed models and reliability was assessed by computing indexes of dependability (ID), standard error of measurement (SEM) and minimal detectable change (MDC). Results A systematic error was found between the first and second trial in the sensitivity functions. No systematic error was found in the neuromuscular controller and body sway. The reliability of 15 of 25 parameters and body sway were moderate to excellent when the results of two trials on three days were averaged. To reach an excellent reliability on one day in 7 out of 25 parameters, it was predicted that at least seven trials must be averaged. Conclusion This study shows that system identification techniques are a promising method to assess the underlying systems involved in standing balance in elderly. However, most of the parameters do not appear to be reliable unless a large number of trials are collected across multiple days. To reach an excellent reliability in one third of the parameters, a training session for participants is needed and at least seven trials of two minutes must be performed on one day. PMID:26953694

  20. Relationships between craniocervical posture and pain-related disability in patients with cervico-craniofacial pain

    PubMed Central

    López-de-Uralde-Villanueva, Ibai; Beltran-Alacreu, Hector; Paris-Alemany, Alba; Angulo-Díaz-Parreño, Santiago; La Touche, Roy

    2015-01-01

    Objectives This cross-sectional correlation study explored the relationships between craniocervical posture and pain-related disability in patients with chronic cervico-craniofacial pain (CCFP). Moreover, we investigated the test–retest intrarater reliability of two craniocervical posture measurements: head posture (HP) and the sternomental distance (SMD). Methods Fifty-three asymptomatic subjects and 60 CCFP patients were recruited. One rater measured HP and the SMD using a cervical range of motion device and a digital caliper, respectively. The Spanish versions of the neck disability index and the craniofacial pain and disability inventory were used to assess pain-related disability (neck disability and craniofacial disability, respectively). Results We found no statistically significant correlations between craniocervical posture and pain-related disability variables (HP and neck disability [r=0.105; P>0.05]; HP and craniofacial disability [r=0.132; P>0.05]; SMD and neck disability [r=0.126; P>0.05]; SMD and craniofacial disability [r=0.195; P>0.05]). A moderate positive correlation was observed between HP and SMD for both groups (asymptomatic subjects, r=0.447; CCFP patients, r=0.52). Neck disability was strongly positively correlated with craniofacial disability (r=0.79; P<0.001). The test–retest intrarater reliability of the HP measurement was high for asymptomatic subjects and CCFP patients (intraclass correlation coefficients =0.93 and 0.81, respectively) and for SMD (intra-class correlation coefficient range between 0.76 and 0.99); the test–retest intrarater reliability remained high when evaluated 9 days later. The HP standard error of measurement range was 0.54–0.75 cm, and the minimal detectable change was 1.27–1.74 cm. The SMD standard error of measurement was 2.75–6.24 mm, and the minimal detectable change was 6.42–14.55 mm. Independent t-tests showed statistically significant differences between the asymptomatic individuals and CCFP patients for measures of craniocervical posture, but these differences were very small (mean difference =1.44 cm for HP; 6.24 mm for SMD). The effect sizes reached by these values were estimated to be small for SMD (d=0.38) and medium for HP (d=0.76). Conclusion The results showed no statistically significant correlations between craniocervical posture and variables of pain-related disability, but a strong correlation between the two variables of disability was found. Our findings suggest that small differences between CCFP patients and asymptomatic subjects exist with respect to the two measurements used to assess craniocervical posture (HP and SMD), and these measures demonstrated high test–retest intrarater reliability for both CCFP patients and asymptomatic subjects. PMID:26261425

  1. Determination of dapsone in serum and saliva using reversed-phase high-performance liquid chromatography with ultraviolet or electrochemical detection.

    PubMed

    Moncrieff, J

    1994-03-18

    A simple, extractionless method for the determination of dapsone in serum and saliva is described. Reversed-phase high-performance liquid chromatography is used with UV detection at 295 nm or electrochemical detection at 0.7 V. Diazoxide in buffer is the internal standard for UV detection and practolol for electrochemical detection. Sample preparation is minimal with protein precipitation of serum samples whilst saliva samples are simply diluted with addition of an internal standard. Low-level serum and saliva samples are front-cut on-line with a 3 cm laboratory-made precolumn in the loop position on a standard Valco injection valve. Isocratic separation is achieved on a 250 mm x 4.6 mm I.D. stainless-steel Spherisorb S5 ODS-1 column. The mobile phase for high levels of dapsone is acetonitrile-elution buffer (12:88, v/v) at 2 ml/min and a column temperature of 40 degrees C for both serum and saliva separations. For the low-level assays using electrochemical detection and solid-phase clean-up, the mobile phase is acetonitrile-methanol-elution buffer (9:4:87, v/v/v). The UV and electrochemical detection limits are 25 ng/ml and 200 pg/ml, respectively, in both serum and saliva. This simple method is applicable to the routine monitoring of dapsone levels in serum from leprotic patients and electrochemical detection gives a simple, reliable method for the monitoring of trough values in subjects on anti-malarial prophylaxis.

  2. Reliability of semiquantitative assessment of osteophytes and subchondral cysts on tomosynthesis images by radiologists with different levels of expertise.

    PubMed

    Hayashi, Daichi; Xu, Li; Gusenburg, Jeffrey; Roemer, Frank W; Hunter, David J; Li, Ling; Guermazi, Ali

    2014-01-01

    We aimed to assess reliability of the evaluation of osteophytes and subchondral cysts on tomosynthesis images when read by radiologists with different levels of expertise. Forty subjects aged >40 years had both knees evaluated using tomosynthesis. Images were read by an "experienced" reader (musculoskeletal radiologist with prior experience) and an "inexperienced" reader (radiology resident with no prior experience). Readers graded osteophytes from 0 to 3 and noted the presence/absence of subchondral cysts in four locations of the tibiofemoral joint. Twenty knees were randomly selected and re-read. Inter- and intrareader reliabilities were calculated using overall exact percent agreement and weighted κ statistics. Diagnostic performance of the two readers was compared against magnetic resonance imaging readings by an expert reader (professor of musculoskeletal radiology). The experienced reader showed substantial intrareader reliability for graded reading of osteophytes (90%, κ=0.93), osteophyte detection (95%, κ=0.86) and cyst detection (95%, κ=0.83). The inexperienced reader showed perfect intrareader reliability for cyst detection (100%, κ=1.00) but intrareader reliability for graded reading (75%, κ=0.79) and detection (80%, κ=0.61) of osteophytes was lower than the experienced reader. Inter-reader reliability was 61% (κ=0.72) for graded osteophyte reading, 91% (κ=0.82) for osteophyte detection, and 88% (κ=0.66) for cyst detection. Diagnostic performance of the experienced reader was higher than the inexperienced reader regarding osteophyte detection (sensitivity range 0.74-0.95 vs. 0.54-0.75 for all locations) but diagnostic performance was similar for subchondral cysts. Tomosynthesis offers excellent intrareader reliability regardless of the reader experience, but experience is important for detection of osteophytes.

  3. Reliability of semiquantitative assessment of osteophytes and subchondral cysts on tomosynthesis images by radiologists with different levels of expertise

    PubMed Central

    Hayashi, Daichi; Xu, Li; Gusenburg, Jeffrey; Roemer, Frank W.; Hunter, David J.; Li, Ling; Guermazi, Ali

    2014-01-01

    PURPOSE We aimed to assess reliability of the evaluation of osteophytes and subchondral cysts on tomosynthesis images when read by radiologists with different levels of expertise. MATERIALS AND METHODS Forty subjects aged >40 years had both knees evaluated using tomosynthesis. Images were read by an “experienced” reader (musculoskeletal radiologist with prior experience) and an “inexperienced” reader (radiology resident with no prior experience). Readers graded osteophytes from 0 to 3 and noted the presence/absence of subchondral cysts in four locations of the tibiofemoral joint. Twenty knees were randomly selected and re-read. Inter- and intrareader reliabilities were calculated using overall exact percent agreement and weighted κ statistics. Diagnostic performance of the two readers was compared against magnetic resonance imaging readings by an expert reader (professor of musculoskeletal radiology). RESULTS The experienced reader showed substantial intrareader reliability for graded reading of osteophytes (90%, κ=0.93), osteophyte detection (95%, κ=0.86) and cyst detection (95%, κ=0.83). The inexperienced reader showed perfect intrareader reliability for cyst detection (100%, κ=1.00) but intrareader reliability for graded reading (75%, κ=0.79) and detection (80%, κ=0.61) of osteophytes was lower than the experienced reader. Inter-reader reliability was 61% (κ=0.72) for graded osteophyte reading, 91% (κ=0.82) for osteophyte detection, and 88% (κ=0.66) for cyst detection. Diagnostic performance of the experienced reader was higher than the inexperienced reader regarding osteophyte detection (sensitivity range 0.74–0.95 vs. 0.54–0.75 for all locations) but diagnostic performance was similar for subchondral cysts. CONCLUSION Tomosynthesis offers excellent intrareader reliability regardless of the reader experience, but experience is important for detection of osteophytes. PMID:24834489

  4. Reliable Digit Span: A Systematic Review and Cross-Validation Study

    ERIC Educational Resources Information Center

    Schroeder, Ryan W.; Twumasi-Ankrah, Philip; Baade, Lyle E.; Marshall, Paul S.

    2012-01-01

    Reliable Digit Span (RDS) is a heavily researched symptom validity test with a recent literature review yielding more than 20 studies ranging in dates from 1994 to 2011. Unfortunately, limitations within some of the research minimize clinical generalizability. This systematic review and cross-validation study was conducted to address these…

  5. Reliability and Validity of the Hip Stability Isometric Test (HipSIT): A New Method to Assess Hip Posterolateral Muscle Strength.

    PubMed

    Almeida, Gabriel Peixoto Leão; das Neves Rodrigues, Helena Larissa; de Freitas, Bruno Wesley; de Paula Lima, Pedro Olavo

    2017-12-01

    Study Design Cross-sectional study. Background The Hip Stability Isometric Test (HipSIT) evaluates the strength of the hip posterolateral stabilizers in a position that favors greater activation of the gluteus maximus and gluteus medius and lower activation of the tensor fascia lata. Objectives To check the validity and reliability of the HipSIT and to evaluate the HipSIT in women with patellofemoral pain (PFP). Methods The HipSIT was evaluated with a handheld dynamometer. During testing, the participants were sidelying, with their legs positioned at 45° of hip flexion and 90° of knee flexion. Participants were instructed to raise the knee of the upper leg while keeping the upper and lower heels in contact. To establish reliability and validity, 49 women were tested with the HipSIT by 2 different evaluators on day 1, and then again 7 days later. The strength of the hip extensors, abductors, and external rotators was also evaluated. Twenty women with unilateral PFP were also evaluated. Results The HipSIT has excellent intrarater and interrater reliability. The standard error of measurement was 0.01 kgf/kg, and the minimal detectable change was 0.036 kgf/kg. The HipSIT showed good validity in isolated hip abduction, external rotation, and extension (P<.01). Women with PFP showed a 10% deficit in the HipSIT results for the symptomatic limb (P = .01). Conclusion The HipSIT showed excellent interrater and intrarater reliability, moderate to good validity in women, and was able to identify strength deficits in women with PFP. J Orthop Sports Phys Ther 2017;47(12):906-913. Epub 9 Oct 2017. doi:10.2519/jospt.2017.7274.

  6. Test-retest reliability of biodex system 4 pro for isometric ankle-eversion and -inversion measurement.

    PubMed

    Tankevicius, Gediminas; Lankaite, Doanata; Krisciunas, Aleksandras

    2013-08-01

    The lack of knowledge about isometric ankle testing indicates the need for research in this area. to assess test-retest reliability and to determine the optimal position for isometric ankle-eversion and -inversion testing. Test-retest reliability study. Isometric ankle eversion and inversion were assessed in 3 different dynamometer foot-plate positions: 0°, 7°, and 14° of inversion. Two maximal repetitions were performed at each angle. Both limbs were tested (40 ankles in total). The test was performed 2 times with a period of 7 d between the tests. University hospital. The study was carried out on 20 healthy athletes with no history of ankle sprains. Reliability was assessed using intraclass correlation coefficient (ICC2,1); minimal detectable change (MDC) was calculated using a 95% confidence interval. Paired t test was used to measure statistically significant changes, and P <.05 was considered statistically significant. Eversion and inversion peak torques showed high ICCs in all 3 angles (ICC values .87-.96, MDC values 3.09-6.81 Nm). Eversion peak torque was the smallest when testing at the 0° angle and gradually increased, reaching maximum values at 14° angle. The increase of eversion peak torque was statistically significant at 7 ° and 14° of inversion. Inversion peak torque showed an opposite pattern-it was the smallest when measured at the 14° angle and increased at the other 2 angles; statistically significant changes were seen only between measures taken at 0° and 14°. Isometric eversion and inversion testing using the Biodex 4 Pro system is a reliable method. The authors suggest that the angle of 7° of inversion is the best for isometric eversion and inversion testing.

  7. "Reliability of the Norwegian version of the short physical performance battery in older people with and without dementia".

    PubMed

    Olsen, Cecilie Fromholt; Bergland, Astrid

    2017-06-09

    The purpose of the study was to establish the test-retest reliability of the Norwegian version of the Short Physical Performance Battery (SPPB). This was a cross- sectional reliability study. A convenience sample of 61 older adults with a mean age of 88.4(8.1) was tested by two different physiotherapists at two time points. The mean time interval between tests was 2.5 days. The Intraclass Correlation Coefficient model 3.1 (ICC, 3.1) with 95% confidence intervals as well as the weighted Kappa (K) were used as measures of relative reliability. The Standard Error of Measurement (SEM) and Minimal Detectable Change (MDC) were used to measure absolute reliability. The results were also analyzed for a subgroup of 24 older people with dementia. The ICC reflected high relative reliability for the SPPB summary score and the 4 m walk test (4mwt), both for the total sample (ICC = 0.92, and 0.91 respectively)) and for the subgroup with dementia (ICC = 0.84 and 0.90 respectively). Furthermore, weighted Ks for the SPPB subscales were 0.64 for the chair stand, 0.80 for gait and 0.52 for balance for the total sample and almost identical for the subgroup with dementia. MDC-values at the 95% confidence intervals (MDC95) were calculated at 0.8 for the total score of SPPB and 0.39 m/s for the 4mwt in the total sample. For the subgroup with dementia MDC95 was 1.88 for the total score of SPPB and 0.28 m/s for 4mwt. The SPPB total score and the timed walking test showed overall high relative and absolute reliability for the total sample indicating that the Norwegian version of the SPPB is reliable when used by trained physiotherapists with older people. The reliability of the Norwegian SPPB in older people with dementia seems high, but due to a small sample size this needs further investigation.

  8. Reliably detectable flaw size for NDE methods that use calibration

    NASA Astrophysics Data System (ADS)

    Koshti, Ajay M.

    2017-04-01

    Probability of detection (POD) analysis is used in assessing reliably detectable flaw size in nondestructive evaluation (NDE). MIL-HDBK-1823 and associated mh18232 POD software gives most common methods of POD analysis. In this paper, POD analysis is applied to an NDE method, such as eddy current testing, where calibration is used. NDE calibration standards have known size artificial flaws such as electro-discharge machined (EDM) notches and flat bottom hole (FBH) reflectors which are used to set instrument sensitivity for detection of real flaws. Real flaws such as cracks and crack-like flaws are desired to be detected using these NDE methods. A reliably detectable crack size is required for safe life analysis of fracture critical parts. Therefore, it is important to correlate signal responses from real flaws with signal responses form artificial flaws used in calibration process to determine reliably detectable flaw size.

  9. Reliably Detectable Flaw Size for NDE Methods that Use Calibration

    NASA Technical Reports Server (NTRS)

    Koshti, Ajay M.

    2017-01-01

    Probability of detection (POD) analysis is used in assessing reliably detectable flaw size in nondestructive evaluation (NDE). MIL-HDBK-1823 and associated mh1823 POD software gives most common methods of POD analysis. In this paper, POD analysis is applied to an NDE method, such as eddy current testing, where calibration is used. NDE calibration standards have known size artificial flaws such as electro-discharge machined (EDM) notches and flat bottom hole (FBH) reflectors which are used to set instrument sensitivity for detection of real flaws. Real flaws such as cracks and crack-like flaws are desired to be detected using these NDE methods. A reliably detectable crack size is required for safe life analysis of fracture critical parts. Therefore, it is important to correlate signal responses from real flaws with signal responses form artificial flaws used in calibration process to determine reliably detectable flaw size.

  10. Blood miRNAs as sensitive and specific biological indicators of environmental and occupational exposure to volatile organic compound (VOC).

    PubMed

    Song, Mi-Kyung; Ryu, Jae-Chun

    2015-10-01

    To date, there is still shortage of highly sensitive and specific minimally invasive biomarkers for assessment of environmental toxicants exposure. Because of the significance of microRNA (miRNA) in various diseases, circulating miRNAs in blood may be unique biomarkers for minimally invasive prediction of toxicants exposure. We identified and validated characteristic miRNA expression profiles of human whole blood in workers exposed to volatile organic compounds (VOCs) and compared the usefulness of miRNA indicator of VOCs with the effectiveness of the already used urinary biomarkers of occupational exposure. Using a microarray based approach we screened and detected deregulated miRNAs in their expression in workers exposed to VOCs (toluene [TOL], xylene [XYL] and ethylbenzene [EBZ]). Total 169 workers from four dockyards were enrolled in current study, and 50 subjects of them were used for miRNA microarray analysis. We identified 467 miRNAs for TOL, 211 miRNAs for XYL, and 695 miRNAs for XYL as characteristic discernible exposure indicator, which could discerned each VOC from the control group with higher accuracy, sensitivity, and specificity than urinary biomarkers. Current observations from this study point out that the altered levels of circulating miRNAs can be a reliable novel, minimally invasive biological indicator of occupational exposure to VOCs. Copyright © 2015 Elsevier GmbH. All rights reserved.

  11. Translation, Cross-cultural Adaptation and Validation of the Farsi Version of NIH Task Force's Recommended Multidimensional Minimal Dataset for Research on Chronic Low Back Pain.

    PubMed

    Noormohammadpour, Pardis; Tavana, Bahareh; Mansournia, Mohammad Ali; Zeinalizadeh, Mehdi; Mirzashahi, Babak; Rostami, Mohsen; Kordi, Ramin

    2018-05-01

    Translation and cultural adaptation of the National Institutes of Health (NIH) Task Force's minimal dataset. The purpose of this study was to evaluate validity and reliability of the Farsi version of NIH Task Force's recommended multidimensional minimal dataset for research on chronic low back pain (CLBP). Considering the high treatment cost of CLBP and its increasing prevalence, NIH Pain Consortium developed research standards (including recommendations for definitions, a minimum dataset, and outcomes' report) for studies regarding CLBP. Application of these recommendations could standardize research and improve comparability of different studies in CLBP. This study has three phases: translation of dataset into Farsi and its cultural adaptation, assessment of pre-final version of dataset's comprehensibility via a pilot study, and investigation of the reliability and validity of final version of translated dataset. Subjects were 250 patients with CLBP. Test-retest reliability, content validity, and convergent validity (correlations among different dimensions of dataset and Farsi versions of Oswestry Disability Index, Roland Morris Disability Questionnaire, Fear-Avoidance Belief Questionnaire, and Beck Depression Inventory-II) were assessed. The Farsi version demonstrated good/excellent convergent validity (the correlation coefficient between impact dimension and ODI was r = 0.75 [P < 0.001], between impact dimension and Roland-Morris Disability Questionnaire was r = 0.80 [P < 0.001], and between psychological dimension and BDI was r = 0.62 [P < 0.001]). The test-retest reliability was also strong (intraclass correlation coefficient value ranged between 0.70 and 0.95) and the internal consistency was good/excellent (Chronbach's alpha coefficients' value for two main dimensions including impact dimension and psychological dimension were 0.91 and 0.82 [P < 0.001], respectively). In addition, its face validity and content validity were acceptable. The Farsi version of minimal dataset for research on CLBP is a reliable and valid instrument for data gathering in patients with CLBP. This minimum dataset can be a step toward standardization of research regarding CLBP. 3.

  12. MEMS device for mass market gas and chemical sensors

    NASA Astrophysics Data System (ADS)

    Kinkade, Brian R.; Daly, James T.; Johnson, Edward A.

    2000-08-01

    Gas and chemical sensors are used in many applications. Industrial health and safety monitors allow companies to meet OSHA requirements by detecting harmful levels of toxic or combustible gases. Vehicle emissions are tested during annual inspections. Blood alcohol breathalizers are used by law enforcement. Refrigerant leak detection ensures that the Earth's ozone layer is not being compromised. Industrial combustion emissions are also monitored to minimize pollution. Heating and ventilation systems watch for high levels of carbon dioxide (CO2) to trigger an increase in fresh air exchange. Carbon monoxide detectors are used in homes to prevent poisoning from poor combustion ventilation. Anesthesia gases are monitored during a patients operation. The current economic reality is that two groups of gas sensor technologies are competing in two distinct existing market segments - affordable (less reliable) chemical reaction sensors for consumer markets and reliable (expensive) infrared (IR) spectroscopic sensors for industrial, laboratory, and medical instrumentation markets. Presently high volume mass-market applications are limited to CO detectros and on-board automotive emissions sensors. Due to reliability problems with electrochemical sensor-based CO detectors there is a hesitancy to apply these sensors in other high volume applications. Applications such as: natural gas leak detection, non-invasive blood glucose monitoring, home indoor air quality, personal/portable air quality monitors, home fire/burnt cooking detector, and home food spoilage detectors need a sensor that is a small, efficient, accurate, sensitive, reliable, and inexpensive. Connecting an array of these next generation gas sensors to wireless networks that are starting to proliferate today creates many other applications. Asthmatics could preview the air quality of their destinations as they venture out into the day. HVAC systems could determine if fresh air intake was actually better than the air in the house. Internet grocery delivery services could check for spoiled foods in their clients' refrigerators. City emissions regulators could monitor the various emissions sources throughout the area from their desk to predict how many pollution vouchers they will need to trade in the next week. We describe a new component architecture for mass-market sensors based on silicon microelectromechanical systems (MEMS) technology. MEMS are micrometer-scale devices that can be fabricated as discrete devices or large arrays, using the technology of integrated circuit manufacturing. These new photonic bandgap and MEMS fabricataion technologies will simplify the component technology to provide high-quality gas and chemical sensors at consumer prices.

  13. Exploratory procedures with carbon nanotube-based sensors for propellant degradation determinations

    NASA Astrophysics Data System (ADS)

    Ruffin, Paul B.; Edwards, Eugene; Brantley, Christina; McDonald, Brian

    2010-04-01

    Exploratory research is conducted at the US Army Aviation & Missile Research, Development, and Engineering Center (AMRDEC) in order to perform assessments of the degradation of solid propellant used in rocket motors. Efforts are made to discontinue and/or minimize destructive methods and utilize nondestructive techniques to assure the quality and reliability of the weaponry's propulsion system. Collaborative efforts were successfully made between AMRDEC and NASA-Ames for potential add-on configurations to a previously designed sensor that AMRDEC plan to use for preliminary detection of off-gassing. Evaluations were made in order to use the design as the introductory component for the determination of shelf-life degradation rate of rocket motors. Previous and subsequent sensor designs utilize functionalized single-walled carbon nano-tubes (SWCNTs) as the key sensing element. On-going research is conducted to consider key changes that can be implemented (for the existing sensor design) such that a complete wireless sensor system design can be realized. Results should be a cost-saving and timely approach to enhance the Army's ability to develop methodologies for measuring weaponry off-gassing and simultaneously detecting explosives. Expectations are for the resulting sensors to enhance the warfighters' ability to simultaneously detect a greater variety of analytes. Outlined in this paper are the preliminary results that have been accomplished for this research. The behavior of the SWCNT sensor at storage temperatures is outlined, along with the initial sensor response to propellant related analytes. Preparatory computer-based programming routines and computer controlled instrumentation scenarios have been developed in order to subsequently minimize subjective interpretation of test results and provide a means for obtaining data that is reasonable and repetitively quantitative. Typical laboratory evaluation methods are likewise presented, and program limitations/barriers are outlined.

  14. Preliminary validation of the military low back pain questionnaire.

    PubMed

    Roy, Tanja C; Fish, Karen L; Lopez, Heather P; Piva, Sara R

    2014-02-01

    Soldiers must perform a variety of physical tasks that the civilian population does not. The Modified Oswestry Disability Index (M-ODI) is the most widely used measure of function in patients with low back pain but does not include military tasks. The Military Low Back Pain Questionnaire (MBQ) was developed by military Physical Therapists to include tasks such as wearing body armor. The purpose of this study was to provide preliminary evidence for the reliability, responsiveness, and validity of the MBQ in nondeployed Soldiers. The MBQ had good reliability compared to the M-ODI. The inter-rater correlation coefficient for the M-ODI was 0.79 and 0.75 for the MBQ. Cronbach's alpha was 0.75 and 0.85 for the M-ODI and MBQ, respectively. The minimal detectable change for the M-ODI was 21.03 and 22.97 for the MBQ. Responsiveness was assessed using a global rating of change; area under the curve for the M-ODI was 0.82 and 0.90 for the MBQ. The correlation between the M-ODI and the MBQ was r = 0.80 indicating good concurrent validity. The MBQ was as reliable as the M-ODI in an Army population. There were trends in the psychometrics suggesting the MBQ may be more sensitive to change than the M-ODI in this population. Reprint & Copyright © 2014 Association of Military Surgeons of the U.S.

  15. Translation and Validation of the Dutch Western Ontario Meniscal Evaluation Tool.

    PubMed

    van der Wal, Robert J P; Heemskerk, Bastiaan T J; van Arkel, Ewoud R A; Mokkink, Lidwine B; Thomassen, Bregje J W

    2017-05-01

    The aim of this study was to translate the Western Ontario Meniscal Evaluation Tool (WOMET) into Dutch, to evaluate the content validity, construct validity, reliability, and responsiveness, and to determine the minimal important change (MIC) of the Dutch version. The WOMET was translated into Dutch according to a standardized forward-backward translation protocol. A total of 86 patients (51 males, 35 females, median age 52 years [interquartile range, 43-60 years]) with isolated meniscal pathology were included. The WOMET was completed three times; at baseline, around 2 weeks, and after 3 months from the baseline. Knee injury and osteoarthritis outcome score, International Knee Documentation Committee subjective knee form, short-form 36, and an anchor question were also answered. There were good results for content validity (floor and ceiling effects [< 15%]), construct validity (79% of the predefined hypotheses were confirmed), internal consistency (Cronbach α = 0.87, 0.79, and 0.86 for each subscale score), test-retest reliability (intraclass correlation coefficient = 0.78 for total WOMET score), and responsiveness (79% of the predefined hypotheses were confirmed). The smallest detectable change and MIC for the Dutch WOMET are 20.5 and 14.7, respectively. The Dutch version of the WOMET is valid and reliable for assessing health-related quality of life in patients with meniscal pathology. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  16. Student Involvement in Assessment: A Project Designed to Assess Class Participation Fairly and Reliably

    ERIC Educational Resources Information Center

    Dancer, Diane; Kamvounias, Patty

    2005-01-01

    This article describes a project designed to ensure that class participation in a large introductory commercial law course is assessed fairly and reliably. The subjectivity often associated with this type of assessment is minimized by involving students in the specification of clear criteria and the assessment process as they were asked to assess…

  17. Computational methods for efficient structural reliability and reliability sensitivity analysis

    NASA Technical Reports Server (NTRS)

    Wu, Y.-T.

    1993-01-01

    This paper presents recent developments in efficient structural reliability analysis methods. The paper proposes an efficient, adaptive importance sampling (AIS) method that can be used to compute reliability and reliability sensitivities. The AIS approach uses a sampling density that is proportional to the joint PDF of the random variables. Starting from an initial approximate failure domain, sampling proceeds adaptively and incrementally with the goal of reaching a sampling domain that is slightly greater than the failure domain to minimize over-sampling in the safe region. Several reliability sensitivity coefficients are proposed that can be computed directly and easily from the above AIS-based failure points. These probability sensitivities can be used for identifying key random variables and for adjusting design to achieve reliability-based objectives. The proposed AIS methodology is demonstrated using a turbine blade reliability analysis problem.

  18. Analysis of human tissue optical scattering spectra for the purpose of breast cancer diagnostics using multi-layer perceptron

    NASA Astrophysics Data System (ADS)

    Nuzhny, Anton S.; Shumsky, Sergey A.; Korzhov, Alexey G.; Lyubynskaya, Tatiana E.

    2008-02-01

    Optical scattering spectra obtained in the clinical trials of breast cancer diagnostic system were analyzed for the purpose to detect in the dataflow the segments corresponding to malignant tissues. Minimal invasive probe with optical fibers inside delivers white light from the source and collects the scattering light while being moved through the tissue. The sampling rate is 100 Hz and each record contains the results of measurements of scattered light intensity at 184 fixed wavelength points. Large amount of information acquired in each procedure, fuzziness in criteria of 'cancer' family membership and data noisiness make neural networks to be an attractive tool for analysis of these data. To define the dividing rule between 'cancer' and 'non-cancer' spectral families a three-layer perceptron was applied. In the process of perceptron learning back propagation method was used to minimize the learning error. Regularization was done using the Bayesian approach. The learning sample was formed by the experts. End-to-end probability calculation throughout the procedure dataset showed reliable detection of the 'cancer' segments. Much attention was paid on the spectra of the tissues with high blood content. Often the reason is vessel injury caused by the penetrating optical probe. But also it can be a dense vessel net surrounding the malignant tumor. To make the division into 'cancer' and 'non-cancer' families for the tissues with high blood content a special perceptron was learnt exceptionally on such spectra.

  19. Signal detection theory and methods for evaluating human performance in decision tasks

    NASA Technical Reports Server (NTRS)

    Obrien, Kevin; Feldman, Evan M.

    1993-01-01

    Signal Detection Theory (SDT) can be used to assess decision making performance in tasks that are not commonly thought of as perceptual. SDT takes into account both the sensitivity and biases in responding when explaining the detection of external events. In the standard SDT tasks, stimuli are selected in order to reveal the sensory capabilities of the observer. SDT can also be used to describe performance when decisions must be made as to the classification of easily and reliably sensed stimuli. Numbers are stimuli that are minimally affected by sensory processing and can belong to meaningful categories that overlap. Multiple studies have shown that the task of categorizing numbers from overlapping normal distributions produces performance predictable by SDT. These findings are particularly interesting in view of the similarity between the task of the categorizing numbers and that of determining the status of a mechanical system based on numerical values that represent sensor readings. Examples of the use of SDT to evaluate performance in decision tasks are reviewed. The methods and assumptions of SDT are shown to be effective in the measurement, evaluation, and prediction of human performance in such tasks.

  20. A novel analytical method for d-glucosamine quantification and its application in the analysis of chitosan degradation by a minimal enzyme cocktail.

    PubMed

    Mekasha, Sophanit; Toupalová, Hana; Linggadjaja, Eka; Tolani, Harish A; Anděra, Ladislav; Arntzen, Magnus Ø; Vaaje-Kolstad, Gustav; Eijsink, Vincent G H; Agger, Jane W

    2016-10-04

    Enzymatic depolymerization of chitosan, a β-(1,4)-linked polycationic polysaccharide composed of d-glucosamine (GlcN) and N-acetyl-d-glucosamine (GlcNAc) provides a possible route to the exploitation of chitin-rich biomass. Complete conversion of chitosan to mono-sugars requires the synergistic action of endo- and exo- chitosanases. In the present study we have developed an efficient and cost-effective chitosan-degrading enzyme cocktail containing only two enzymes, an endo-attacking bacterial chitosanase, ScCsn46A, from Streptomyces coelicolor, and an exo-attacking glucosamine specific β-glucosaminidase, Tk-Glm, from the archaeon Thermococcus kodakarensis KOD1. Moreover, we developed a fast, reliable quantitative method for analysis of GlcN using high performance anion exchange chromatography with pulsed amperometric detection (HPAEC-PAD). The sensitivity of this method is high and less than 50 pmol was easily detected, which is about 1000-fold better than the sensitivity of more commonly used detection methods based on refractive index. We also obtained qualitative insight into product development during the enzymatic degradation reaction by means of ElectroSpray Ionization-Mass Spectrometry (ESI-MS). Copyright © 2016 Elsevier Ltd. All rights reserved.

  1. Standard operating procedures for serum and plasma collection: early detection research network consensus statement standard operating procedure integration working group.

    PubMed

    Tuck, Melissa K; Chan, Daniel W; Chia, David; Godwin, Andrew K; Grizzle, William E; Krueger, Karl E; Rom, William; Sanda, Martin; Sorbara, Lynn; Stass, Sanford; Wang, Wendy; Brenner, Dean E

    2009-01-01

    Specimen collection is an integral component of clinical research. Specimens from subjects with various stages of cancers or other conditions, as well as those without disease, are critical tools in the hunt for biomarkers, predictors, or tests that will detect serious diseases earlier or more readily than currently possible. Analytic methodologies evolve quickly. Access to high-quality specimens, collected and handled in standardized ways that minimize potential bias or confounding factors, is key to the "bench to bedside" aim of translational research. It is essential that standard operating procedures, "the how" of creating the repositories, be defined prospectively when designing clinical trials. Small differences in the processing or handling of a specimen can have dramatic effects in analytical reliability and reproducibility, especially when multiplex methods are used. A representative working group, Standard Operating Procedures Internal Working Group (SOPIWG), comprised of members from across Early Detection Research Network (EDRN) was formed to develop standard operating procedures (SOPs) for various types of specimens collected and managed for our biomarker discovery and validation work. This report presents our consensus on SOPs for the collection, processing, handling, and storage of serum and plasma for biomarker discovery and validation.

  2. Developing a model for hospital inherent safety assessment: Conceptualization and validation.

    PubMed

    Yari, Saeed; Akbari, Hesam; Gholami Fesharaki, Mohammad; Khosravizadeh, Omid; Ghasemi, Mohammad; Barsam, Yalda; Akbari, Hamed

    2018-01-01

    Paying attention to the safety of hospitals, as the most crucial institute for providing medical and health services wherein a bundle of facilities, equipment, and human resource exist, is of significant importance. The present research aims at developing a model for assessing hospitals' safety based on principles of inherent safety design. Face validity (30 experts), content validity (20 experts), construct validity (268 examples), convergent validity, and divergent validity have been employed to validate the prepared questionnaire; and the items analysis, the Cronbach's alpha test, ICC test (to measure reliability of the test), composite reliability coefficient have been used to measure primary reliability. The relationship between variables and factors has been confirmed at 0.05 significance level by conducting confirmatory factor analysis (CFA) and structural equations modeling (SEM) technique with the use of Smart-PLS. R-square and load factors values, which were higher than 0.67 and 0.300 respectively, indicated the strong fit. Moderation (0.970), simplification (0.959), substitution (0.943), and minimization (0.5008) have had the most weights in determining the inherent safety of hospital respectively. Moderation, simplification, and substitution, among the other dimensions, have more weight on the inherent safety, while minimization has the less weight, which could be due do its definition as to minimize the risk.

  3. Survey of critical failure events in on-chip interconnect by fault tree analysis

    NASA Astrophysics Data System (ADS)

    Yokogawa, Shinji; Kunii, Kyousuke

    2018-07-01

    In this paper, a framework based on reliability physics is proposed for adopting fault tree analysis (FTA) to the on-chip interconnect system of a semiconductor. By integrating expert knowledge and experience regarding the possibilities of failure on basic events, critical issues of on-chip interconnect reliability will be evaluated by FTA. In particular, FTA is used to identify the minimal cut sets with high risk priority. Critical events affecting the on-chip interconnect reliability are identified and discussed from the viewpoint of long-term reliability assessment. The moisture impact is evaluated as an external event.

  4. Fluorescent "on-off-on" switching sensor based on CdTe quantum dots coupled with multiwalled carbon nanotubes@graphene oxide nanoribbons for simultaneous monitoring of dual foreign DNAs in transgenic soybean.

    PubMed

    Li, Yaqi; Sun, Li; Qian, Jing; Long, Lingliang; Li, Henan; Liu, Qian; Cai, Jianrong; Wang, Kun

    2017-06-15

    With the increasing concern of potential health and environmental risk, it is essential to develop reliable methods for transgenic soybean detection. Herein, a simple, sensitive and selective assay was constructed based on homogeneous fluorescence resonance energy transfer (FRET) between CdTe quantum dots (QDs) and multiwalled carbon nanotubes@graphene oxide nanoribbons (MWCNTs@GONRs) to form the fluorescent "on-off-on" switching for simultaneous monitoring dual target DNAs of promoter cauliflower mosaic virus 35s (P35s) and terminator nopaline synthase (TNOS) from transgenic soybean. The capture DNAs were immobilized with corresponding QDs to obtain strong fluorescent signals (turning on). The strong π-π stacking interaction between single-stranded DNA (ssDNA) probes and MWCNTs@GONRs led to minimal background fluorescence due to the FRET process (turning off). The targets of P35s and TNOS were recognized by dual fluorescent probes to form double-stranded DNA (dsDNA) through the specific hybridization between target DNAs and ssDNA probes. And the dsDNA were released from the surface of MWCNTs@GONRs, which leaded the dual fluorescent probes to generate the strong fluorescent emissions (turning on). Therefore, this proposed homogeneous assay can be achieved to detect P35s and TNOS simultaneously by monitoring the relevant fluorescent emissions. Moreover, this assay can distinguish complementary and mismatched nucleic acid sequences with high sensitivity. The constructed approach has the potential to be a tool for daily detection of genetically modified organism with the merits of feasibility and reliability. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Evaluation of real time PCR assays for the detection and enumeration of enterohemorrhagic Escherichia coli directly from cattle feces.

    PubMed

    Luedtke, Brandon E; Bono, James L; Bosilevac, Joseph M

    2014-10-01

    Shiga toxin-producing Escherichia coli are a growing concern in the area of food safety, and the United States Department of Agriculture Food Safety and Inspection Service has identified the serotypes O26, O45, O103, O111, O121, O145, and O157 as adulterants in certain types of raw beef. The most relevant to human disease are the enterohemorrhagic E. coli (EHEC) strains that possess intimin (eae), Shiga toxin 1 and/or 2 (stx1-2), and in most cases the conserved pO157 or pO157 like virulence plasmid. Contamination of raw beef with EHEC is likely to occur via the transfer of cattle feces on hides to the carcass. To detect EHEC directly from cattle feces, we evaluated the utility of a multiplex real time PCR assay that targets the EHEC associated gene target ecf1 in combination with eae and stx1-2. Our assay had an increased sensitivity and provided a reliable limit of detection (LOD) of 1.25×10(3)colony-forming unitspermL (CFUs/mL) in an EHEC spiked fecal background. In addition, we evaluated the use of a duplex qPCR assay using ecf1 for the enumeration of total EHEC directly from cattle feces. The reliable limit of quantification (LOQ) was determined to be 1.25×10(3)CFUs/mL. Our assay requires minimal sample processing and provides LOD and LOQ of EHEC directly from cattle feces that are the lowest reported. The application of this assay towards the identification of cattle shedding EHEC at a level above 1.25×10(3)CFUs/mL could be a first line of defense in identifying cattle shedding these pathogens. Published by Elsevier B.V.

  6. Mission Reliability Estimation for Repairable Robot Teams

    NASA Technical Reports Server (NTRS)

    Trebi-Ollennu, Ashitey; Dolan, John; Stancliff, Stephen

    2010-01-01

    A mission reliability estimation method has been designed to translate mission requirements into choices of robot modules in order to configure a multi-robot team to have high reliability at minimal cost. In order to build cost-effective robot teams for long-term missions, one must be able to compare alternative design paradigms in a principled way by comparing the reliability of different robot models and robot team configurations. Core modules have been created including: a probabilistic module with reliability-cost characteristics, a method for combining the characteristics of multiple modules to determine an overall reliability-cost characteristic, and a method for the generation of legitimate module combinations based on mission specifications and the selection of the best of the resulting combinations from a cost-reliability standpoint. The developed methodology can be used to predict the probability of a mission being completed, given information about the components used to build the robots, as well as information about the mission tasks. In the research for this innovation, sample robot missions were examined and compared to the performance of robot teams with different numbers of robots and different numbers of spare components. Data that a mission designer would need was factored in, such as whether it would be better to have a spare robot versus an equivalent number of spare parts, or if mission cost can be reduced while maintaining reliability using spares. This analytical model was applied to an example robot mission, examining the cost-reliability tradeoffs among different team configurations. Particularly scrutinized were teams using either redundancy (spare robots) or repairability (spare components). Using conservative estimates of the cost-reliability relationship, results show that it is possible to significantly reduce the cost of a robotic mission by using cheaper, lower-reliability components and providing spares. This suggests that the current design paradigm of building a minimal number of highly robust robots may not be the best way to design robots for extended missions.

  7. Psychometric Evaluation of the Brachial Assessment Tool Part 1: Reproducibility.

    PubMed

    Hill, Bridget; Williams, Gavin; Olver, John; Ferris, Scott; Bialocerkowski, Andrea

    2018-04-01

    To evaluate reproducibility (reliability and agreement) of the Brachial Assessment Tool (BrAT), a new patient-reported outcome measure for adults with traumatic brachial plexus injury (BPI). Prospective repeated-measure design. Outpatient clinics. Adults with confirmed traumatic BPI (N=43; age range, 19-82y). People with BPI completed the 31-item 4-response BrAT twice, 2 weeks apart. Results for the 3 subscales and summed score were compared at time 1 and time 2 to determine reliability, including systematic differences using paired t tests, test retest using intraclass correlation coefficient model 1,1 (ICC 1,1 ), and internal consistency using Cronbach α. Agreement parameters included standard error of measurement, minimal detectable change, and limits of agreement. BrAT. Test-retest reliability was excellent (ICC 1,1 =.90-.97). Internal consistency was high (Cronbach α=.90-.98). Measurement error was relatively low (standard error of measurement range, 3.1-8.8). A change of >4 for subscale 1, >6 for subscale 2, >4 for subscale 3, and >10 for the summed score is indicative of change over and above measurement error. Limits of agreement ranged from ±4.4 (subscale 3) to 11.61 (summed score). These findings support the use of the BrAT as a reproducible patient-reported outcome measure for adults with traumatic BPI with evidence of appropriate reliability and agreement for both individual and group comparisons. Further psychometric testing is required to establish the construct validity and responsiveness of the BrAT. Copyright © 2017 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  8. Between-Day Reliability of Pre-Participation Screening Components in Pre-Professional Ballet and Contemporary Dancers.

    PubMed

    Kenny, Sarah J; Palacios-Derflingher, Luz; Owoeye, Oluwatoyosi B A; Whittaker, Jackie L; Emery, Carolyn A

    2018-03-15

    Critical appraisal of research investigating risk factors for musculoskeletal injury in dancers suggests high quality reliability studies are lacking. The purpose of this study was to determine between-day reliability of pre-participation screening (PPS) components in pre-professional ballet and contemporary dancers. Thirty-eight dancers (35 female, 3 male; median age; 18 years; range: 11 to 30 years) participated. Screening components (Athletic Coping Skills Inventory-28, body mass index, percent total body fat, total bone mineral density, Foot Posture Index-6, hip and ankle range of motion, three lumbopelvic control tasks, unipedal dynamic balance, and the Y-Balance Test) were conducted one week apart. Intra-class correlation coefficients (ICCs: 95% confidence intervals), standard error of measurement, minimal detectable change (MDC), Bland-Altman methods of agreement [95% limits of agreement (LOA)], Cohen's kappa coefficients, standard error, and percent agreements were calculated. Depending on the screening component, ICC estimates ranged from 0.51 to 0.98, kappa coefficients varied between -0.09 and 0.47, and percent agreement spanned 71% to 95%. Wide 95% LOA were demonstrated by Foot Posture Index-6 (right: -6.06, 7.31), passive hip external rotation (right: -9.89, 16.54), and passive supine turnout (left: -15.36, 17.58). The PPS components examined demonstrated moderate to excellent relative reliability with mean between-day differences less than MDC, or sufficient percent agreement, across all assessments. However, due to wide 95% limits of agreement, the Foot Posture Index-6 and passive hip range of motion are not recommended for screening injury risk in pre-professional dancers.

  9. 24/7 security system: 60-FPS color EMCCD camera with integral human recognition

    NASA Astrophysics Data System (ADS)

    Vogelsong, T. L.; Boult, T. E.; Gardner, D. W.; Woodworth, R.; Johnson, R. C.; Heflin, B.

    2007-04-01

    An advanced surveillance/security system is being developed for unattended 24/7 image acquisition and automated detection, discrimination, and tracking of humans and vehicles. The low-light video camera incorporates an electron multiplying CCD sensor with a programmable on-chip gain of up to 1000:1, providing effective noise levels of less than 1 electron. The EMCCD camera operates in full color mode under sunlit and moonlit conditions, and monochrome under quarter-moonlight to overcast starlight illumination. Sixty frame per second operation and progressive scanning minimizes motion artifacts. The acquired image sequences are processed with FPGA-compatible real-time algorithms, to detect/localize/track targets and reject non-targets due to clutter under a broad range of illumination conditions and viewing angles. The object detectors that are used are trained from actual image data. Detectors have been developed and demonstrated for faces, upright humans, crawling humans, large animals, cars and trucks. Detection and tracking of targets too small for template-based detection is achieved. For face and vehicle targets the results of the detection are passed to secondary processing to extract recognition templates, which are then compared with a database for identification. When combined with pan-tilt-zoom (PTZ) optics, the resulting system provides a reliable wide-area 24/7 surveillance system that avoids the high life-cycle cost of infrared cameras and image intensifiers.

  10. HPLC-MRM relative quantification analysis of fatty acids based on a novel derivatization strategy.

    PubMed

    Cai, Tie; Ting, Hu; Xin-Xiang, Zhang; Jiang, Zhou; Jin-Lan, Zhang

    2014-12-07

    Fatty acids (FAs) are associated with a series of diseases including tumors, diabetes, and heart diseases. As potential biomarkers, FAs have attracted increasing attention from both biological researchers and the pharmaceutical industry. However, poor ionization efficiency, extreme diversity, strict dependence on internal standards and complicated multiple reaction monitoring (MRM) optimization protocols have challenged efforts to quantify FAs. In this work, a novel derivatization strategy based on 2,4-bis(diethylamino)-6-hydrazino-1,3,5-triazine was developed to enable quantification of FAs. The sensitivity of FA detection was significantly enhanced as a result of the derivatization procedure. FA quantities as low as 10 fg could be detected by high-performance liquid chromatography coupled with triple-quadrupole mass spectrometry. General MRM conditions were developed for any FA, which facilitated the quantification and extended the application of the method. The FA quantification strategy based on HPLC-MRM was carried out using deuterated derivatization reagents. "Heavy" derivatization reagents were used as internal standards (ISs) to minimize matrix effects. Prior to statistical analysis, amounts of each FA species were normalized by their corresponding IS, which guaranteed the accuracy and reliability of the method. FA changes in plasma induced by ageing were studied using this strategy. Several FA species were identified as potential ageing biomarkers. The sensitivity, accuracy, reliability, and full coverage of the method ensure that this strategy has strong potential for both biomarker discovery and lipidomic research.

  11. Item response modeling: a psychometric assessment of the children's fruit, vegetable, water, and physical activity self-efficacy scales among Chinese children.

    PubMed

    Wang, Jing-Jing; Chen, Tzu-An; Baranowski, Tom; Lau, Patrick W C

    2017-09-16

    This study aimed to evaluate the psychometric properties of four self-efficacy scales (i.e., self-efficacy for fruit (FSE), vegetable (VSE), and water (WSE) intakes, and physical activity (PASE)) and to investigate their differences in item functioning across sex, age, and body weight status groups using item response modeling (IRM) and differential item functioning (DIF). Four self-efficacy scales were administrated to 763 Hong Kong Chinese children (55.2% boys) aged 8-13 years. Classical test theory (CTT) was used to examine the reliability and factorial validity of scales. IRM was conducted and DIF analyses were performed to assess the characteristics of item parameter estimates on the basis of children's sex, age and body weight status. All self-efficacy scales demonstrated adequate to excellent internal consistency reliability (Cronbach's α: 0.79-0.91). One FSE misfit item and one PASE misfit item were detected. Small DIF were found for all the scale items across children's age groups. Items with medium to large DIF were detected in different sex and body weight status groups, which will require modification. A Wright map revealed that items covered the range of the distribution of participants' self-efficacy for each scale except VSE. Several self-efficacy scales' items functioned differently by children's sex and body weight status. Additional research is required to modify the four self-efficacy scales to minimize these moderating influences for application.

  12. Dental hygiene faculty calibration in the evaluation of calculus detection.

    PubMed

    Garland, Kandis V; Newell, Kathleen J

    2009-03-01

    The purpose of this pilot study was to explore the impact of faculty calibration training on intra- and interrater reliability regarding calculus detection. After IRB approval, twelve dental hygiene faculty members were recruited from a pool of twenty-two for voluntary participation and randomized into two groups. All subjects provided two pre- and two posttest scorings of calculus deposits on each of three typodonts by recording yes or no indicating if they detected calculus. Accuracy and consistency of calculus detection were evaluated using an answer key. The experimental group received three two-hour training sessions to practice a prescribed exploring sequence and technique for calculus detection. Participants immediately corrected their answers, received feedback from the trainer, and reconciled missed areas. Intra- and interrater reliability (pre- and posttest) was determined using Cohen's Kappa and compared between groups using repeated measures (split-plot) ANOVA. The groups did not differ from pre- to posttraining (intrarater reliability p=0.64; interrater reliability p=0.20). Training had no effect on reliability levels for simulated calculus detection in this study. Recommendations for future studies of faculty calibration when evaluating students include using patients for assessing rater reliability, employing larger samples at multiple sites, and assessing the impact on students' attitudes and learning outcomes.

  13. Designing safety into the minimally invasive surgical revolution: a commentary based on the Jacques Perissat Lecture of the International Congress of the European Association for Endoscopic Surgery.

    PubMed

    Clarke, John R

    2009-01-01

    Surgical errors with minimally invasive surgery differ from those in open surgery. Perforations are typically the result of trocar introduction or electrosurgery. Infections include bioburdens, notably enteric viruses, on complex instruments. Retained foreign objects are primarily unretrieved device fragments and lost gallstones or other specimens. Fires and burns come from illuminated ends of fiber-optic cables and from electrosurgery. Pressure ischemia is more likely with longer endoscopic surgical procedures. Gas emboli can occur. Minimally invasive surgery is more dependent on complex equipment, with high likelihood of failures. Standardization, checklists, and problem reporting are solutions for minimizing failures. The necessity of electrosurgery makes education about best electrosurgical practices important. The recording of minimally invasive surgical procedures is an opportunity to debrief in a way that improves the reliability of future procedures. Safety depends on reliability, designing systems to withstand inevitable human errors. Safe systems are characterized by a commitment to safety, formal protocols for communications, teamwork, standardization around best practice, and reporting of problems for improvement of the system. Teamwork requires shared goals, mental models, and situational awareness in order to facilitate mutual monitoring and backup. An effective team has a flat hierarchy; team members are empowered to speak up if they are concerned about problems. Effective teams plan, rehearse, distribute the workload, and debrief. Surgeons doing minimally invasive surgery have a unique opportunity to incorporate the principles of safety into the development of their discipline.

  14. Validity, Reliability, and Ability to Identify Fall Status of the Berg Balance Scale, BESTest, Mini-BESTest, and Brief-BESTest in Patients With COPD.

    PubMed

    Jácome, Cristina; Cruz, Joana; Oliveira, Ana; Marques, Alda

    2016-11-01

    The Berg Balance Scale (BBS), Balance Evaluation Systems Test (BESTest), Mini-BESTest, and Brief-BESTest are useful in the assessment of balance. Their psychometric properties, however, have not been tested in patients with chronic obstructive pulmonary disease (COPD). This study aimed to compare the validity, reliability, and ability to identify fall status of the BBS, BESTest, Mini-BESTest, and the Brief-BESTest in patients with COPD. A cross-sectional study was conducted. Forty-six patients (24 men, 22 women; mean age=75.9 years, SD=7.1) were included. Participants were asked to report their falls during the previous 12 months and to fill in the Activity-specific Balance Confidence (ABC) Scale. The BBS and the BESTest were administered. Mini-BESTest and Brief-BESTest scores were computed based on the participants' BESTest performance. Validity was assessed by correlating balance tests with each other and with the ABC Scale. Interrater reliability (2 raters), intrarater reliability (48-72 hours), and minimal detectable changes (MDCs) were established. Receiver operating characteristics assessed the ability of each balance test to differentiate between participants with and without a history of falls. Balance test scores were significantly correlated with each other (Spearman correlation rho=.73-.90) and with the ABC Scale (rho=.53-.75). Balance tests presented high interrater reliability (intraclass correlation coefficient [ICC]=.85-.97) and intrarater reliability (ICC=.52-.88) and acceptable MDCs (MDC=3.3-6.3 points). Although all balance tests were able to identify fall status (area under the curve=0.74-0.84), the BBS (sensitivity=73%, specificity=77%) and the Brief-BESTest (sensitivity=81%, specificity=73%) had the higher ability to identify fall status. Findings are generalizable mainly to older patients with moderate COPD. The 4 balance tests are valid, reliable, and valuable in identifying fall status in patients with COPD. The Brief-BESTest presented slightly higher interrater reliability and ability to differentiate participants' fall status. © 2016 American Physical Therapy Association.

  15. Application of Probability of Crack Detection to Aircraft Systems Reliability.

    DOT National Transportation Integrated Search

    1993-08-31

    This report describes three tasks related to probability of crack detection (POD) and aircraft systems reliablity. All three consider previous work in which crack growth simulations and crack detection data in the Service Difficulty Report (SDR) data...

  16. Development of a Tablet-based symbol digit modalities test for reliably assessing information processing speed in patients with stroke.

    PubMed

    Tung, Li-Chen; Yu, Wan-Hui; Lin, Gong-Hong; Yu, Tzu-Ying; Wu, Chien-Te; Tsai, Chia-Yin; Chou, Willy; Chen, Mei-Hsiang; Hsieh, Ching-Lin

    2016-09-01

    To develop a Tablet-based Symbol Digit Modalities Test (T-SDMT) and to examine the test-retest reliability and concurrent validity of the T-SDMT in patients with stroke. The study had two phases. In the first phase, six experts, nine college students and five outpatients participated in the development and testing of the T-SDMT. In the second phase, 52 outpatients were evaluated twice (2 weeks apart) with the T-SDMT and SDMT to examine the test-retest reliability and concurrent validity of the T-SDMT. The T-SDMT was developed via expert input and college student/patient feedback. Regarding test-retest reliability, the practise effects of the T-SDMT and SDMT were both trivial (d=0.12) but significant (p≦0.015). The improvement in the T-SDMT (4.7%) was smaller than that in the SDMT (5.6%). The minimal detectable changes (MDC%) of the T-SDMT and SDMT were 6.7 (22.8%) and 10.3 (32.8%), respectively. The T-SDMT and SDMT were highly correlated with each other at the two time points (Pearson's r=0.90-0.91). The T-SDMT demonstrated good concurrent validity with the SDMT. Because the T-SDMT had a smaller practise effect and less random measurement error (superior test-retest reliability), it is recommended over the SDMT for assessing information processing speed in patients with stroke. Implications for Rehabilitation The Symbol Digit Modalities Test (SDMT), a common measure of information processing speed, showed a substantial practise effect and considerable random measurement error in patients with stroke. The Tablet-based SDMT (T-SDMT) has been developed to reduce the practise effect and random measurement error of the SDMT in patients with stroke. The T-SDMT had smaller practise effect and random measurement error than the SDMT, which can provide more reliable assessments of information processing speed.

  17. Measurements of Weight Bearing Asymmetry Using the Nintendo Wii Fit Balance Board Are Not Reliable for Older Adults and Individuals With Stroke.

    PubMed

    Liuzzo, Derek M; Peters, Denise M; Middleton, Addie; Lanier, Wes; Chain, Rebecca; Barksdale, Brittany; Fritz, Stacy L

    Clinicians and researchers have used bathroom scales, balance performance monitors with feedback, postural scale analysis, and force platforms to evaluate weight bearing asymmetry (WBA). Now video game consoles offer a novel alternative for assessing this construct. By using specialized software, the Nintendo Wii Fit balance board can provide reliable measurements of WBA in healthy, young adults. However, reliability of measurements obtained using only the factory settings to assess WBA in older adults and individuals with stroke has not been established. To determine whether measurements of WBA obtained using the Nintendo Wii Fit balance board and default settings are reliable in older adults and individuals with stroke. Weight bearing asymmetry was assessed using the Nintendo Wii Fit balance board in 2 groups of participants-individuals older than 65 years (n = 41) and individuals with stroke (n = 41). Participants were given a standardized set of instructions and were not provided auditory or visual feedback. Two trials were performed. Intraclass correlation coefficients (ICC), standard error of measure (SEM), and minimal detectable change (MDC) scores were determined for each group. The ICC for the older adults sample was 0.59 (0.35-0.76) with SEM95 = 6.2% and MDC95 = 8.8%. The ICC for the sample including individuals with stroke was 0.60 (0.47-0.70) with SEM95 = 9.6% and MDC95 = 13.6%. Although measurements of WBA obtained using the Nintendo Wii Fit balance board, and its default factory settings, demonstrate moderate reliability in older adults and individuals with stroke, the relatively high associated SEM and MDC values substantially reduce the clinical utility of the Nintendo Wii Fit balance board as an assessment tool for WBA. Weight bearing asymmetry cannot be measured reliably in older adults and individuals with stroke using the Nintendo Wii Fit balance board without the use of specialized software.

  18. Measurements of Weight Bearing Asymmetry Using the Nintendo Wii Fit Balance Board Are Not Reliable for Older Adults and Individuals With Stroke

    PubMed Central

    Liuzzo, Derek M.; Peters, Denise M.; Middleton, Addie; Lanier, Wes; Chain, Rebecca; Barksdale, Brittany; Fritz, Stacy L.

    2015-01-01

    Background Clinicians and researchers have used bathroom scales, balance performance monitors with feedback, postural scale analysis, and force platforms to evaluate weight bearing asymmetry (WBA). Now video game consoles offer a novel alternative for assessing this construct. By using specialized software, the Nintendo Wii Fit balance board can provide reliable measurements of WBA in healthy, young adults. However, reliability of measurements obtained using only the factory settings to assess WBA in older adults and individuals with stroke has not been established. Purpose To determine whether measurements of WBA obtained using the Nintendo Wii Fit balance board and default settings are reliable in older adults and individuals with stroke. Methods Weight bearing asymmetry was assessed using the Nintendo Wii Fit balance board in 2 groups of participants—individuals older than 65 years (n = 41) and individuals with stroke (n = 41). Participants were given a standardized set of instructions and were not provided auditory or visual feedback. Two trials were performed. Intraclass correlation coefficients (ICC), standard error of measure (SEM), and minimal detectable change (MDC) scores were determined for each group. Results The ICC for the older adults sample was 0.59 (0.35–0.76) with SEM95= 6.2% and MDC95= 8.8%. The ICC for the sample including individuals with stroke was 0.60 (0.47–0.70) with SEM95= 9.6% and MDC95= 13.6%. Discussion Although measurements of WBA obtained using the Nintendo Wii Fit balance board, and its default factory settings, demonstrate moderate reliability in older adults and individuals with stroke, the relatively high associated SEM and MDC values substantially reduce the clinical utility of the Nintendo Wii Fit balance board as an assessment tool for WBA. Conclusions Weight bearing asymmetry cannot be measured reliably in older adults and individuals with stroke using the Nintendo Wii Fit balance board without the use of specialized software. PMID:26288237

  19. Validity and reliability of an instrumented leg-extension machine for measuring isometric muscle strength of the knee extensors.

    PubMed

    Ruschel, Caroline; Haupenthal, Alessandro; Jacomel, Gabriel Fernandes; Fontana, Heiliane de Brito; Santos, Daniela Pacheco dos; Scoz, Robson Dias; Roesler, Helio

    2015-05-20

    Isometric muscle strength of knee extensors has been assessed for estimating performance, evaluating progress during physical training, and investigating the relationship between isometric and dynamic/functional performance. To assess the validity and reliability of an adapted leg-extension machine for measuring isometric knee extensor force. Validity (concurrent approach) and reliability (test and test-retest approach) study. University laboratory. 70 healthy men and women aged between 20 and 30 y (39 in the validity study and 31 in the reliability study). Intraclass correlation coefficient (ICC) values calculated for the maximum voluntary isometric torque of knee extensors at 30°, 60°, and 90°, measured with the prototype and with an isokinetic dynamometer (ICC2,1, validity study) and measured with the prototype in test and retest sessions, scheduled from 48 h to 72 h apart (ICC1,1, reliability study). In the validity analysis, the prototype showed good agreement for measurements at 30° (ICC2,1 = .75, SEM = 18.2 Nm) and excellent agreement for measurements at 60° (ICC2,1 = .93, SEM = 9.6 Nm) and at 90° (ICC2,1 = .94, SEM = 8.9 Nm). Regarding the reliability analysis, between-days' ICC1,1 were good to excellent, ranging from .88 to .93. Standard error of measurement and minimal detectable difference based on test-retest ranged from 11.7 Nm to 18.1 Nm and 32.5 Nm to 50.1 Nm, respectively, for the 3 analyzed knee angles. The analysis of validity and repeatability of the prototype for measuring isometric muscle strength has shown to be good or excellent, depending on the knee joint angle analyzed. The new instrument, which presents a relative low cost and easiness of transportation when compared with an isokinetic dynamometer, is valid and provides consistent data concerning isometric strength of knee extensors and, for this reason, can be used for practical, clinical, and research purposes.

  20. Construct validity and reliability of the Finnish version of the Knee Injury and Osteoarthritis Outcome Score.

    PubMed

    Multanen, Juhani; Honkanen, Mikko; Häkkinen, Arja; Kiviranta, Ilkka

    2018-05-22

    The Knee Injury and Osteoarthritis Outcome Score (KOOS) is a commonly used knee assessment and outcome tool in both clinical work and research. However, it has not been formally translated and validated in Finnish. The purpose of this study was to translate and culturally adapt the KOOS questionnaire into Finnish and to determine its validity and reliability among Finnish middle-aged patients with knee injuries. KOOS was translated and culturally adapted from English into Finnish. Subsequently, 59 patients with knee injuries completed the Finnish version of KOOS, Western Ontario and McMaster Osteoarthritis Index (WOMAC), Short-Form 36 Health Survey (SF-36) and Numeric Pain Rating Scale (Pain-NRS). The same KOOS questionnaire was re-administered 2 weeks later. Psychometric assessment of the Finnish KOOS was performed by testing its construct validity and reliability by using internal consistency, test-retest reliability and measurement error. The floor and ceiling effects were also examined. The cross-cultural adaptation revealed only minor cultural differences and was well received by the patients. For construct validity, high to moderate Spearman's Correlation Coefficients were found between the KOOS subscales and the WOMAC, SF-36, and Pain-NRS subscales. The Cronbach's alpha was from 0.79 to 0.96 for all subscales indicating acceptable internal consistency. The test-retest reliability was good to excellent, with Intraclass Correlation Coefficients ranging from 0.73 to 0.86 for all KOOS subscales. The minimal detectable change ranged from 17 to 34 on an individual level and from 2 to 4 on a group level. No floor or ceiling effects were observed. This study yielded an appropriately translated and culturally adapted Finnish version of KOOS which demonstrated good validity and reliability. Our data indicate that the Finnish version of KOOS is suitable for assessment of the knee status of Finnish patients with different knee complaints. Further studies are needed to evaluate the predictive ability of KOOS in the Finnish population.

  1. Reliability and validation of the Dutch Achilles tendon Total Rupture Score.

    PubMed

    Opdam, K T M; Zwiers, R; Wiegerinck, J I; Kleipool, A E B; Haverlag, R; Goslings, J C; van Dijk, C N

    2018-03-01

    Patient-reported outcome measures (PROMs) have become a cornerstone for the evaluation of the effectiveness of treatment. The Achilles tendon Total Rupture Score (ATRS) is a PROM for outcome and assessment of an Achilles tendon rupture. The aim of this study was to translate the ATRS to Dutch and evaluate its reliability and validity in the Dutch population. A forward-backward translation procedure was performed according to the guidelines of cross-cultural adaptation process. The Dutch ATRS was evaluated for reliability and validity in patients treated for a total Achilles tendon rupture from 1 January 2012 to 31 December 2014 in one teaching hospital and one academic hospital. Reliability was assessed by the intraclass correlation coefficients (ICC), Cronbach's alpha and minimal detectable change (MDC). We assessed construct validity by calculation of Spearman's rho correlation coefficient with domains of the Foot and Ankle Outcome Score (FAOS), Victorian Institute of Sports Assessment-Achilles questionnaire (VISA-A) and Numeric Rating Scale (NRS) for pain in rest and during running. The Dutch ATRS had a good test-retest reliability (ICC = 0.852) and a high internal consistency (Cronbach's alpha = 0.96). MDC was 30.2 at individual level and 3.5 at group level. Construct validity was supported by 75 % of the hypothesized correlations. The Dutch ATRS had a strong correlation with NRS for pain during running (r = -0.746) and all the five subscales of the Dutch FAOS (r = 0.724-0.867). There was a moderate correlation with the VISA-A-NL (r = 0.691) and NRS for pain in rest (r = -0.580). The Dutch ATRS shows an adequate reliability and validity and can be used in the Dutch population for measuring the outcome of treatment of a total Achilles tendon rupture and for research purposes. Diagnostic study, Level I.

  2. Virtual reality as a metric for the assessment of laparoscopic psychomotor skills. Learning curves and reliability measures.

    PubMed

    Gallagher, A G; Satava, R M

    2002-12-01

    The objective assessment of the psychomotor skills of surgeons is now a priority; however, this is a difficult task because of measurement difficulties associated with the assessment of surgery in vivo. In this study, virtual reality (VR) was used to overcome these problems. Twelve experienced (>50 minimal-access procedures), 12 inexperienced laparoscopic surgeons (<10 minimal-access procedures), and 12 laparoscopic novices participated in the study. Each subject completed 10 trials on the Minimally Invasive Surgical Trainer; Virtual Reality (MIST VR). Experienced laparoscopic surgeons performed the tasks significantly (p < 0.01) faster, with less error, more economy in the movement of instruments and the use of diathermy, and with greater consistency in performance. The standardized coefficient alpha for performance measures ranged from a = 0.89 to 0.98, showing high internal measurement consistency. Test-retest reliability ranged from r = 0.96 to r = 0.5. VR is a useful tool for evaluating the psychomotor skills needed to perform laparoscopic surgery.

  3. Co-detection: ultra-reliable nanoparticle-based electrical detection of biomolecules in the presence of large background interference.

    PubMed

    Liu, Yang; Gu, Ming; Alocilja, Evangelyn C; Chakrabartty, Shantanu

    2010-11-15

    An ultra-reliable technique for detecting trace quantities of biomolecules is reported. The technique called "co-detection" exploits the non-linear redundancy amongst synthetically patterned biomolecular logic circuits for deciphering the presence or absence of target biomolecules in a sample. In this paper, we verify the "co-detection" principle on gold-nanoparticle-based conductimetric soft-logic circuits which use a silver-enhancement technique for signal amplification. Using co-detection, we have been able to demonstrate a great improvement in the reliability of detecting mouse IgG at concentration levels that are 10(5) lower than the concentration of rabbit IgG which serves as background interference. Copyright © 2010 Elsevier B.V. All rights reserved.

  4. Translation, cross-cultural adaptation and validation of the Persian version of COOP/WONCA charts in Persian-speaking Iranians with multiple sclerosis.

    PubMed

    Taghipour, Morteza; Salavati, Mahyar; Nabavi, Seyed Massood; Akhbari, Behnam; Ebrahimi Takamjani, Ismail; Negahban, Hossein; Rajabzadeh, Fatemeh

    2018-03-01

    Translation, cross-culturally adaptation and validation of a Persian version of COOP/WONCA charts in Persian-speaking Iranians with multiple sclerosis (MS). The Persian version of COOP/WONCA charts was developed after a standard forward translation, synthesis and backward translation. A total of 197 subjects with MS participated in this study. They were asked to complete the COOP/WONCA charts and Short-Form 36 Health Survey (SF-36). The COOP/WONCA charts were re-administered to 50 patients, 4 weeks after the first session. Expanded Disability Status Scale (EDSS) was also scored for each subject by the referring physician. Construct validity was assessed by testing linear relationship between corresponding domains of the COOP/WONCA charts, the SF-36 and the EDSS. Test-retest reliability was examined using interclass correlation coefficient (ICC), standard error of measurement (SEM) and minimal detectable change (MDC) values. Related domains of COOP/WONCA charts and SF-36 demonstrated strong linear relationships with Spearman's coefficients ranging from -0.51 to -0.75 (p< 0.05). Physical fitness and daily activity charts also demonstrated strong relationships with the EDSS by Spearman's coefficients of 0.65 and 0.50, respectively (p< 0.05). The ICC values for most of COOP/WONCA charts domains were acceptable (>0.70) except for feelings and quality-of-life domains that were 0.50 and 0.51, respectively. The Persian version of the COOP/WONCA charts was shown to be psychometrically appropriate to evaluate the functional level and quality of life in Persian-speaking Iranians with MS. Implications for rehabilitation COOP/WONCA charts are now available in Persian and demonstrate good psychometric properties. COOP/WONCA charts demonstrate excellent reliability and construct validity in a Persian-speaking Iranian population with MS. Minimal detectable change in COOP/WONCA is now available in MS to guide within and between group analyses. Knowledge on a wide variety of physical, mental and emotional parameters as well as the status of patients' symptoms, daily activities and quality of life helps rehabilitation clinicians and service providers plan preventive and remedial interventions more effectively.

  5. Morcellation of undiagnosed uterine sarcoma: A critical review.

    PubMed

    Bogani, Giorgio; Chiappa, Valentina; Ditto, Antonino; Martinelli, Fabio; Donfrancesco, Cristina; Indini, Alice; Lorusso, Domenica; Raspagliesi, Francesco

    2016-02-01

    In the recent decades, laparoscopy has replaced open abdominal procedures in the setting of gynecologic surgery. Extraction of large specimens (e.g., large uteri or myomas) following operative laparoscopy is technically challenging. Technological attempts allow the removal of large and solid pelvic masses via small abdominal incisions (using instruments called morcellators), thus reducing unnecessary laparotomies and improving short-term patients' outcomes. However, morcellation of undiagnosed uterine malignancies may lead to worse survival outcomes. Therefore, the Food and Drug Administration (FDA) warns about the use of power morcellators, thus causing ongoing concerns on the applicability of minimally invasive approaches for myomectomy and the removal of large uteri. In the present review, we sought to assess pro and cons regarding minimally invasive morcellation. This review will discuss the effects of morcellation of undiagnosed uterine malignancies, focusing on possible techniques for preoperative detection of uterine sarcoma and for avoiding intra-abdominal dissemination of potentially malignant tissues. Further efforts are necessary in order to identify tools to make a more accurate and reliable preoperative diagnosis of uterine masses. However, on the light of the current evidence, intra-abdominal morcellation should be banned from clinical practice. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  6. A Spanish validation of the Coma Recovery Scale-Revised (CRS-R).

    PubMed

    Tamashiro, Mercedes; Rivas, Maria Elisa; Ron, Melania; Salierno, Fernando; Dalera, Marisol; Olmos, Lisandro

    2014-01-01

    Analysis of inter-rater reliability and concurrent validity. To determine measurement properties of a Spanish version of The Coma Recovery Scale-Revised (CRS-R). A sample of 35 in-patients with severe acquired brain injury. To test concurrent validity of the translated scale, the Glasgow Coma Scale (GSC) and Disability Rating Scale (DRS) were also administered. Two experts in the field were recruited to assess inter-rater agreement. Inter-rater reliability was good for total CRS-R scores (Cronbach α = 0.973, p = 0.001). Sub-scale analysis showed moderate-to-high inter-rater agreement. Total CRS-R scores correlated significantly (p < 0.05) with total GCS (r = 0.74) and DRS (r = 0.54) scores, indicating acceptable concurrent validity. The Spanish version of CRS-R can be administered reliably by trained and experienced examiners. CRS-R appears capable of differentiating patients in Emergence from Minimally Conscious State (EMCS) or in Minimally Conscious State (MCS) from those in a Vegetative State (VS).

  7. Reliability design and verification for launch-vehicle propulsion systems - Report of an AIAA Workshop, Washington, DC, May 16, 17, 1989

    NASA Astrophysics Data System (ADS)

    Launch vehicle propulsion system reliability considerations during the design and verification processes are discussed. The tools available for predicting and minimizing anomalies or failure modes are described and objectives for validating advanced launch system propulsion reliability are listed. Methods for ensuring vehicle/propulsion system interface reliability are examined and improvements in the propulsion system development process are suggested to improve reliability in launch operations. Also, possible approaches to streamline the specification and procurement process are given. It is suggested that government and industry should define reliability program requirements and manage production and operations activities in a manner that provides control over reliability drivers. Also, it is recommended that sufficient funds should be invested in design, development, test, and evaluation processes to ensure that reliability is not inappropriately subordinated to other management considerations.

  8. How to improve the standardization and the diagnostic performance of the fecal egg count reduction test?

    PubMed

    Levecke, Bruno; Kaplan, Ray M; Thamsborg, Stig M; Torgerson, Paul R; Vercruysse, Jozef; Dobson, Robert J

    2018-04-15

    Although various studies have provided novel insights into how to best design, analyze and interpret a fecal egg count reduction test (FECRT), it is still not straightforward to provide guidance that allows improving both the standardization and the analytical performance of the FECRT across a variety of both animal and nematode species. For example, it has been suggested to recommend a minimum number of eggs to be counted under the microscope (not eggs per gram of feces), but we lack the evidence to recommend any number of eggs that would allow a reliable assessment of drug efficacy. Other aspects that need further research are the methodology of calculating uncertainty intervals (UIs; confidence intervals in case of frequentist methods and credible intervals in case of Bayesian methods) and the criteria of classifying drug efficacy into 'normal', 'suspected' and 'reduced'. The aim of this study is to provide complementary insights into the current knowledge, and to ultimately provide guidance in the development of new standardized guidelines for the FECRT. First, data were generated using a simulation in which the 'true' drug efficacy (TDE) was evaluated by the FECRT under varying scenarios of sample size, analytic sensitivity of the diagnostic technique, and level of both intensity and aggregation of egg excretion. Second, the obtained data were analyzed with the aim (i) to verify which classification criteria allow for reliable detection of reduced drug efficacy, (ii) to identify the UI methodology that yields the most reliable assessment of drug efficacy (coverage of TDE) and detection of reduced drug efficacy, and (iii) to determine the required sample size and number of eggs counted under the microscope that optimizes the detection of reduced efficacy. Our results confirm that the currently recommended criteria for classifying drug efficacy are the most appropriate. Additionally, the UI methodologies we tested varied in coverage and ability to detect reduced drug efficacy, thus a combination of UI methodologies is recommended to assess the uncertainty across all scenarios of drug efficacy estimates. Finally, based on our model estimates we were able to determine the required number of eggs to count for each sample size, enabling investigators to optimize the probability of correctly classifying a theoretical TDE while minimizing both financial and technical resources. Copyright © 2018 Elsevier B.V. All rights reserved.

  9. Effective channel estimation and efficient symbol detection for multi-input multi-output underwater acoustic communications

    NASA Astrophysics Data System (ADS)

    Ling, Jun

    Achieving reliable underwater acoustic communications (UAC) has long been recognized as a challenging problem owing to the scarce bandwidth available and the reverberant spread in both time and frequency domains. To pursue high data rates, we consider a multi-input multi-output (MIMO) UAC system, and our focus is placed on two main issues regarding a MIMO UAC system: (1) channel estimation, which involves the design of the training sequences and the development of a reliable channel estimation algorithm, and (2) symbol detection, which requires interference cancelation schemes due to simultaneous transmission from multiple transducers. To enhance channel estimation performance, we present a cyclic approach for designing training sequences with good auto- and cross-correlation properties, and a channel estimation algorithm called the iterative adaptive approach (IAA). Sparse channel estimates can be obtained by combining IAA with the Bayesian information criterion (BIC). Moreover, we present sparse learning via iterative minimization (SLIM) and demonstrate that SLIM gives similar performance to IAA but at a much lower computational cost. Furthermore, an extension of the SLIM algorithm is introduced to estimate the sparse and frequency modulated acoustic channels. The extended algorithm is referred to as generalization of SLIM (GoSLIM). Regarding symbol detection, a linear minimum mean-squared error based detection scheme, called RELAX-BLAST, which is a combination of vertical Bell Labs layered space-time (V-BLAST) algorithm and the cyclic principle of the RELAX algorithm, is presented and it is shown that RELAX-BLAST outperforms V-BLAST. We show that RELAX-BLAST can be implemented efficiently by making use of the conjugate gradient method and diagonalization properties of circulant matrices. This fast implementation approach requires only simple fast Fourier transform operations and facilitates parallel implementations. The effectiveness of the proposed MIMO schemes is verified by both computer simulations and experimental results obtained by analyzing the measurements acquired in multiple in-water experiments.

  10. Detecting Lung and Colorectal Cancer Recurrence Using Structured Clinical/Administrative Data to Enable Outcomes Research and Population Health Management.

    PubMed

    Hassett, Michael J; Uno, Hajime; Cronin, Angel M; Carroll, Nikki M; Hornbrook, Mark C; Ritzwoller, Debra

    2017-12-01

    Recurrent cancer is common, costly, and lethal, yet we know little about it in community-based populations. Electronic health records and tumor registries contain vast amounts of data regarding community-based patients, but usually lack recurrence status. Existing algorithms that use structured data to detect recurrence have limitations. We developed algorithms to detect the presence and timing of recurrence after definitive therapy for stages I-III lung and colorectal cancer using 2 data sources that contain a widely available type of structured data (claims or electronic health record encounters) linked to gold-standard recurrence status: Medicare claims linked to the Cancer Care Outcomes Research and Surveillance study, and the Cancer Research Network Virtual Data Warehouse linked to registry data. Twelve potential indicators of recurrence were used to develop separate models for each cancer in each data source. Detection models maximized area under the ROC curve (AUC); timing models minimized average absolute error. Algorithms were compared by cancer type/data source, and contrasted with an existing binary detection rule. Detection model AUCs (>0.92) exceeded existing prediction rules. Timing models yielded absolute prediction errors that were small relative to follow-up time (<15%). Similar covariates were included in all detection and timing algorithms, though differences by cancer type and dataset challenged efforts to create 1 common algorithm for all scenarios. Valid and reliable detection of recurrence using big data is feasible. These tools will enable extensive, novel research on quality, effectiveness, and outcomes for lung and colorectal cancer patients and those who develop recurrence.

  11. Novel real-time polymerase chain reaction assay for simultaneous detection of recurrent fusion genes in acute myeloid leukemia.

    PubMed

    Dolz, Sandra; Barragán, Eva; Fuster, Óscar; Llop, Marta; Cervera, José; Such, Esperanza; De Juan, Inmaculada; Palanca, Sarai; Murria, Rosa; Bolufer, Pascual; Luna, Irene; Gómez, Inés; López, María; Ibáñez, Mariam; Sanz, Miguel A

    2013-09-01

    The recent World Health Organization classification recognizes different subtypes of acute myeloid leukemia (AML) according to the presence of several recurrent genetic abnormalities. Detection of these abnormalities and other molecular changes is of increasing interest because it contributes to a refined diagnosis and prognostic assessment in AML and enables monitoring of minimal residual disease. These genetic abnormalities can be detected using single RT-PCR, although the screening is still labor intensive and costly. We have developed a novel real-time RT-PCR assay to simultaneously detect 15 AML-associated rearrangements that is a simple and easily applicable method for use in clinical diagnostic laboratories. This method showed 100% specificity and sensitivity (95% confidence interval, 91% to 100% and 92% to 100%, respectively). The procedure was validated in a series of 105 patients with AML. The method confirmed all translocations detected using standard cytogenetics and fluorescence in situ hybridization and some additional undetected rearrangements. Two patients demonstrated two molecular rearrangements simultaneously, with BCR-ABL1 implicated in both, in addition to RUNX1-MECOM in one patient and PML-RARA in another. In conclusion, this novel real-time RT-PCR assay for simultaneous detection of multiple AML-associated fusion genes is a versatile and sensitive method for reliable screening of recurrent rearrangements in AML. Copyright © 2013 American Society for Investigative Pathology and the Association for Molecular Pathology. Published by Elsevier Inc. All rights reserved.

  12. Validity and Reliability of Dynamic Visual Acuity (DVA) Measurement During Walking

    NASA Technical Reports Server (NTRS)

    Deshpande, Nandini; Peters, Brian T.; Bloomberg, Jacob J.

    2014-01-01

    DVA is primarily subserved by the vestibulo-ocular reflex mechanism. Individuals with vestibular hypofunction commonly experience highly debilitating illusory movement or blurring of visual images during daily activities possibly, due to impaired DVA. Even without pathologies, gradual age-related morphological deterioration is evident in all components of the vestibular system. We examined the construct validity to detect age-related differences and test-retest reliability of DVA measurements performed during walking. METHODS: Healthy adults were recruited into 3 groups: 1. young (20-39years, n=18), 2. middle-aged (40-59years, n=14), and 3. older adults (60-80years, n=15). Randomly selected seven participants from each group (n=21) participated in retesting. Participants were excluded if they had a history of vestibular or neuromuscular pathologies, dizziness/vertigo or >1 falls in the past year. Older persons with MMSE scores <29/30 were excluded to minimize cognitive errors. Participants' age, height, weight and normal walking speed were recorded. The binocular DVA was measured while walking on a treadmill at 0.8 m/s, 1.0 m/s and 1.2 m/s speeds. The walking speeds chosen represent a range of slow to moderate walking speeds for adult life span in participants who have no current mobility problems. The monitor that displayed Landolt 'C' optotypes was placed at 50 cm from the eyes for nearDVA (primary compensation by otolith organs) and at 3.0 m for farDVA (primary compensation by semicircular canals). A mixed factor ANOVA (age group x speed) was performed separately for the Near and FarDVA for detecting group differences. Intraclass correlation coefficients (ICCs) were calculated for each condition to determine test-retest reliability. RESULTS: The three age groups were not different in their height, weight and normal walking speed (p>0.05). The post hoc analyses for DVA measurements demonstrated that each group was significantly different from the other two groups for Near as well as FarDVA (p<0.001-p=0.031). The effect of speed was significant for both NearDVA (p=0.012) and FarDVA (p=0.014), however, there was no age group x speed interaction (FarDVA p=0.607, NearDVA p=0.343). The ICCs for Near and FarDVA ranged between 0.85- 0.88 and 0.71-0.87, respectively. CONCLUSIONS: Differences in DVA between the three age groups were detected by using both Near and FarDVA protocols irrespective of the walking speed. Therefore, age group-specific reference values should be used for detecting malfunction. Further, consistency in walking speed is critical for comparing between studies. NearDVA at all walking speeds and FarDVA at the speed of 1.2 m/s demonstrated excellent testretest reliability. FarDVA at 0.8 m/s and 1.0 m/s demonstrated good test-retest reliability (ICCs 0.71 and 0.77, respectively).

  13. Software IV and V Research Priorities and Applied Program Accomplishments Within NASA

    NASA Technical Reports Server (NTRS)

    Blazy, Louis J.

    2000-01-01

    The mission of this research is to be world-class creators and facilitators of innovative, intelligent, high performance, reliable information technologies that enable NASA missions to (1) increase software safety and quality through error avoidance, early detection and resolution of errors, by utilizing and applying empirically based software engineering best practices; (2) ensure customer software risks are identified and/or that requirements are met and/or exceeded; (3) research, develop, apply, verify, and publish software technologies for competitive advantage and the advancement of science; and (4) facilitate the transfer of science and engineering data, methods, and practices to NASA, educational institutions, state agencies, and commercial organizations. The goals are to become a national Center Of Excellence (COE) in software and system independent verification and validation, and to become an international leading force in the field of software engineering for improving the safety, quality, reliability, and cost performance of software systems. This project addresses the following problems: Ensure safety of NASA missions, ensure requirements are met, minimize programmatic and technological risks of software development and operations, improve software quality, reduce costs and time to delivery, and improve the science of software engineering

  14. Development of X-ray computed tomography inspection facility for the H-II solid rocket boosters

    NASA Astrophysics Data System (ADS)

    Sasaki, M.; Fujita, T.; Fukushima, Y.; Shimizu, M.; Itoh, S.; Satoh, A.; Miyamoto, H.

    The National Space Development Agency of Japan (NASDA) initiated the development of an X-ray computed tomography (CT) equipment for the H-II solid rocket boosters (SRBs) in 1987 for the purpose of minimizing inspection time and achieving high cost-effectiveness. The CT facility has been completed in Jan. 1991 in Tanegashima Space Center for the inspection of the SRBs transported from the manufacturer's factory to the launch site. It was first applied to the qualification model SRB from Feb. to Apr. in 1991. Through the CT inspection of the SRB, it has been confirmed that inspection time decreased significantly compared with the X-ray radiography method and that even an unskilled inspector could find various defects. As a result, the establishment of a new reliable inspection method for the SRB has been verified. In this paper, the following are discussed: (1) the defect detectability of the CT equipment using a dummy SRB with various artificial defects, (2) the performance comparison between the CT method and the X-ray radiography method, (3) the reliability of the CT equipment, and (4) the radiation shield design of the nondestructive test building.

  15. Advanced Health Management Algorithms for Crew Exploration Applications

    NASA Technical Reports Server (NTRS)

    Davidson, Matt; Stephens, John; Jones, Judit

    2005-01-01

    Achieving the goals of the President's Vision for Exploration will require new and innovative ways to achieve reliability increases of key systems and sub-systems. The most prominent approach used in current systems is to maintain hardware redundancy. This imposes constraints to the system and utilizes weight that could be used for payload for extended lunar, Martian, or other deep space missions. A technique to improve reliability while reducing the system weight and constraints is through the use of an Advanced Health Management System (AHMS). This system contains diagnostic algorithms and decision logic to mitigate or minimize the impact of system anomalies on propulsion system performance throughout the powered flight regime. The purposes of the AHMS are to increase the probability of successfully placing the vehicle into the intended orbit (Earth, Lunar, or Martian escape trajectory), increase the probability of being able to safely execute an abort after it has developed anomalous performance during launch or ascent phases of the mission, and to minimize or mitigate anomalies during the cruise portion of the mission. This is accomplished by improving the knowledge of the state of the propulsion system operation at any given turbomachinery vibration protection logic and an overall system analysis algorithm that utilizes an underlying physical model and a wide array of engine system operational parameters to detect and mitigate predefined engine anomalies. These algorithms are generic enough to be utilized on any propulsion system yet can be easily tailored to each application by changing input data and engine specific parameters. The key to the advancement of such a system is the verification of the algorithms. These algorithms will be validated through the use of a database of nominal and anomalous performance from a large propulsion system where data exists for catastrophic and noncatastrophic propulsion sytem failures.

  16. Evaluation of Intradermal and Subcutaneous Infusion Set Performance Under 24-Hour Basal and Bolus Conditions

    PubMed Central

    McVey, Elaine; Keith, Steven; Herr, Joshua K.; Sutter, Diane; Pettis, Ronald J.

    2015-01-01

    Background: This study sought to assess the function and delivery reliability of intradermal (ID) infusion sets used with commercial insulin pumps. Method: Healthy subjects (n = 43) were randomized to either ID or subcutaneous (SC) arms, and received basal/bolus placebo delivery for 24 hours. Subjects received 4 of 8 infusion set combinations (ID: microneedle design A or B, with 2 pump brands [Animas or MiniMed]; SC: Teflon Quickset or steel Rapid-D, Animas pump only, with or without overtaping) and were evaluated for pump occlusion alarms, fluid leakage, pain, and tissue tolerability. A novel algorithm was developed to determine flow consistency based on fluid pressure, and the duration and occurrence rate for periods of unalarmed but interrupted flow (“silent occlusions’”) were compared. Results: ID delivery was successfully maintained over the 24-hour infusion period. The number of silent occlusions was lower for ID microneedle cannula design B than A (P < .01) and lower for Rapid-D SC device compared to Quick-set (P = .03). There was no significant difference in the number of occlusion alarms between the ID and SC devices with the Animas pump. However, the pumps tested with ID devices had significantly different alarm rates (MiniMed 29.5%, Animas 0%, P < .001). Leakage and tissue tolerability were comparable across devices. Conclusion: The ID infusion set reliably delivered diluent for an extended 24-hour period in healthy subjects and was well tolerated. Silent occlusion flow interruptions could be detected in both ID and SC infusion sets using a proprietary algorithm. This algorithm is a promising method for quantitatively evaluating infusion set flow performance. PMID:26319228

  17. A method for generating reliable atomistic models of amorphous polymers based on a random search of energy minima

    NASA Astrophysics Data System (ADS)

    Curcó, David; Casanovas, Jordi; Roca, Marc; Alemán, Carlos

    2005-07-01

    A method for generating atomistic models of dense amorphous polymers is presented. The method is organized in a two-steps procedure. First, structures are generated using an algorithm that minimizes the torsional strain. After this, a relaxation algorithm is applied to minimize the non-bonding interactions. Two alternative relaxation methods, which are based simple minimization and Concerted Rotation techniques, have been implemented. The performance of the method has been checked by simulating polyethylene, polypropylene, nylon 6, poly(L,D-lactic acid) and polyglycolic acid.

  18. Reliability analysis of interdependent lattices

    NASA Astrophysics Data System (ADS)

    Limiao, Zhang; Daqing, Li; Pengju, Qin; Bowen, Fu; Yinan, Jiang; Zio, Enrico; Rui, Kang

    2016-06-01

    Network reliability analysis has drawn much attention recently due to the risks of catastrophic damage in networked infrastructures. These infrastructures are dependent on each other as a result of various interactions. However, most of the reliability analyses of these interdependent networks do not consider spatial constraints, which are found important for robustness of infrastructures including power grid and transport systems. Here we study the reliability properties of interdependent lattices with different ranges of spatial constraints. Our study shows that interdependent lattices with strong spatial constraints are more resilient than interdependent Erdös-Rényi networks. There exists an intermediate range of spatial constraints, at which the interdependent lattices have minimal resilience.

  19. Detection of minimal residual disease following induction immunochemotherapy predicts progression free survival in mantle cell lymphoma: final results of CALGB 59909

    PubMed Central

    Liu, Hongtao; Johnson, Jeffrey L.; Koval, Greg; Malnassy, Greg; Sher, Dorie; Damon, Lloyd E.; Hsi, Eric D.; Bucci, Donna Marie; Linker, Charles A.; Cheson, Bruce D.; Stock, Wendy

    2012-01-01

    Background In the present study, the prognostic impact of minimal residual disease during treatment on time to progression and overall survival was analyzed prospectively in patients with mantle cell lymphoma treated on the Cancer and Leukemia Group B 59909 clinical trial. Design and Methods Peripheral blood and bone marrow samples were collected during different phases of the Cancer and Leukemia Group B 59909 study for minimal residual disease analysis. Minimal residual disease status was determined by quantitative polymerase chain reaction of IgH and/or BCL-1/JH gene rearrangement. Correlation of minimal residual disease status with time to progression and overall survival was determined. In multivariable analysis, minimal residual disease, and other risk factors were correlated with time to progression. Results Thirty-nine patients had evaluable, sequential peripheral blood and bone marrow samples for minimal residual disease analysis. Using peripheral blood monitoring, 18 of 39 (46%) achieved molecular remission following induction therapy. The molecular remission rate increased from 46 to 74% after one course of intensification therapy. Twelve of 21 minimal residual disease positive patients (57%) progressed within three years of follow up compared to 4 of 18 (22%) molecular remission patients (P=0.049). Detection of minimal residual disease following induction therapy predicted disease progression with a hazard ratio of 3.7 (P=0.016). The 3-year probability of time to progression among those who were in molecular remission after induction chemotherapy was 82% compared to 48% in patients with detectable minimal residual disease. The prediction of time to progression by post-induction minimal residual disease was independent of other prognostic factors in multivariable analysis. Conclusions Detection of minimal residual disease following induction immunochemotherapy was an independent predictor of time to progression following immunochemotherapy and autologous stem cell transplantation for mantle cell lymphoma. The clinical trial was registered at ClinicalTrials.gov: NCT00020943. PMID:22102709

  20. Loewenstein communication scale for the minimally responsive patient.

    PubMed

    Borer-Alafi, Nurit; Gil, Mali; Sazbon, Leon; Korn, Cecilia

    2002-07-01

    Any sign of communicative ability in patients in vegetative state can provide information about regain of consciousness and conservation of cognitive abilities. The aim of this study was to test the reliability and validity of an instrument designed to measure the degree of communication in minimally responsive patients. The Loewenstein Communication Scale (LCS) measures five hierarchical functions - mobility, respiration, visual responsiveness, auditory comprehension and linguistic skills (verbal or alternative) - which are divided into five parameters and rated in developmental order on a 5-point scale by level of difficulty. Scores for each function are summed to obtain a quantitative communication profile. Forty-two adult patients in vegetative state, as a result of acquired brain injury, were examined with the proposed LCS for the minimally responsive patients by two speech and language clinicians at admission to the Intensive Care Unit (ICU) for brain injured patients and, thereafter, at least once weekly. At the end of the ICU stay, 27 patients who showed signs of recovery and were referred for continued rehabilitation were compared to a group of 15 patients who were not referred for continued rehabilitation, for functional and general LCS scores. The predictive power of the LCS in differentiating between these groups was tested. The LCS was found to have very good reliability with good inter-rater agreement. Patients who eventually continued rehabilitation had significantly higher total scores as well as in the motor, visual and auditory sub-scales. Logistic regression results indicated that these parameters successfully differentiated between the two groups of patients, even after adjusting for age and for scores on the Glasgow Coma Scale. The LCS for the minimally responsive patients proved to be reliable and predictive of rehabilitation progress of minimally responsive patients. It may be useful for the interdisciplinary rehabilitation team in planning early individually targeted therapeutic programmes. 2002 Taylor & Francis Ltd

  1. MicroRNA Based Liquid Biopsy: The Experience of the Plasma miRNA Signature Classifier (MSC) for Lung Cancer Screening.

    PubMed

    Mensah, Mavis; Borzi, Cristina; Verri, Carla; Suatoni, Paola; Conte, Davide; Pastorino, Ugo; Orazio, Fortunato; Sozzi, Gabriella; Boeri, Mattia

    2017-10-26

    The development of a minimally invasive test, such as liquid biopsy, for early lung cancer detection in its preclinical phase is crucial to improve the outcome of this deadly disease. MicroRNAs (miRNAs) are tissue specific, small, non-coding RNAs regulating gene expression, which may act as extracellular messengers of biological signals derived from the cross-talk between the tumor and its surrounding microenvironment. They could thus represent ideal candidates for early detection of lung cancer. In this work, a methodological workflow for the prospective validation of a circulating miRNA test using custom made microfluidic cards and quantitative Real-Time PCR in plasma samples of volunteers enrolled in a lung cancer screening trial is proposed. In addition, since the release of hemolysis-related miRNAs and more general technical issues may affect the analysis, the quality control steps included in the standard operating procedures are also presented. The protocol is reproducible and gives reliable quantitative results; however, when using large clinical series, both pre-analytical and analytical features should be cautiously evaluated.

  2. Spectral areas and ratios classifier algorithm for pancreatic tissue classification using optical spectroscopy

    NASA Astrophysics Data System (ADS)

    Chandra, Malavika; Scheiman, James; Simeone, Diane; McKenna, Barbara; Purdy, Julianne; Mycek, Mary-Ann

    2010-01-01

    Pancreatic adenocarcinoma is one of the leading causes of cancer death, in part because of the inability of current diagnostic methods to reliably detect early-stage disease. We present the first assessment of the diagnostic accuracy of algorithms developed for pancreatic tissue classification using data from fiber optic probe-based bimodal optical spectroscopy, a real-time approach that would be compatible with minimally invasive diagnostic procedures for early cancer detection in the pancreas. A total of 96 fluorescence and 96 reflectance spectra are considered from 50 freshly excised tissue sites-including human pancreatic adenocarcinoma, chronic pancreatitis (inflammation), and normal tissues-on nine patients. Classification algorithms using linear discriminant analysis are developed to distinguish among tissues, and leave-one-out cross-validation is employed to assess the classifiers' performance. The spectral areas and ratios classifier (SpARC) algorithm employs a combination of reflectance and fluorescence data and has the best performance, with sensitivity, specificity, negative predictive value, and positive predictive value for correctly identifying adenocarcinoma being 85, 89, 92, and 80%, respectively.

  3. The Clinical Relevance of Force Platform Measures in Multiple Sclerosis: A Review

    PubMed Central

    Prosperini, Luca; Pozzilli, Carlo

    2013-01-01

    Balance impairment and falls are frequent in patients with multiple sclerosis (PwMS), and they may occur even at the earliest stage of the disease and in minimally impaired patients. The introduction of computer-based force platform measures (i.e., static and dynamic posturography) has provided an objective and sensitive tool to document both deficits and improvements in balance. By using more challenging test conditions, force platform measures can also reveal subtle balance disorders undetectable by common clinical scales. Furthermore, posturographic techniques may also allow to reliably identify PwMS who are at risk of accidental falls. Although force platform measures offer several theoretical advantages, only few studies extensively investigated their role in better managing PwMS. Standardised procedures, as well as clinical relevance of changes detected by static or dynamic posturography, are still lacking. In this review, we summarized studies which investigated balance deficit by means of force platform measures, focusing on their ability in detecting patients at high risk of falls and in estimating rehabilitation-induced changes, highlighting the pros and the cons with respect to clinical scales. PMID:23766910

  4. Transient partial permeabilization with saponin enables cellular barcoding prior to surface marker staining1

    PubMed Central

    Behbehani, Gregory K.; Thom, Colin; Zunder, Eli R.; Finck, Rachel; Gaudilliere, Brice; Fragiadakis, Gabriela K.; Fantl, Wendy J.; Nolan, Garry P.

    2015-01-01

    Fluorescent cellular barcoding and mass-tag cellular barcoding are cytometric methods that enable high sample throughput, minimize inter-sample variation, and reduce reagent consumption. Previously employed barcoding protocols require that barcoding be performed after surface marker staining, complicating combining the technique with measurement of alcohol-sensitive surface epitopes. This report describes a method of barcoding fixed cells after a transient partial permeabilization with 0.02% saponin that results in efficient and consistent barcode staining with fluorescent or mass-tagged reagents while preserving surface marker staining. This approach simplifies barcoding protocols and allows direct comparison of surface marker staining of multiple samples without concern for variations in the antibody cocktail volume, antigen-antibody ratio, or machine sensitivity. Using this protocol, cellular barcoding can be used to reliably detect subtle differences in surface marker expression. PMID:25274027

  5. Topology of the correlation networks among major currencies using hierarchical structure methods

    NASA Astrophysics Data System (ADS)

    Keskin, Mustafa; Deviren, Bayram; Kocakaplan, Yusuf

    2011-02-01

    We studied the topology of correlation networks among 34 major currencies using the concept of a minimal spanning tree and hierarchical tree for the full years of 2007-2008 when major economic turbulence occurred. We used the USD (US Dollar) and the TL (Turkish Lira) as numeraires in which the USD was the major currency and the TL was the minor currency. We derived a hierarchical organization and constructed minimal spanning trees (MSTs) and hierarchical trees (HTs) for the full years of 2007, 2008 and for the 2007-2008 period. We performed a technique to associate a value of reliability to the links of MSTs and HTs by using bootstrap replicas of data. We also used the average linkage cluster analysis for obtaining the hierarchical trees in the case of the TL as the numeraire. These trees are useful tools for understanding and detecting the global structure, taxonomy and hierarchy in financial data. We illustrated how the minimal spanning trees and their related hierarchical trees developed over a period of time. From these trees we identified different clusters of currencies according to their proximity and economic ties. The clustered structure of the currencies and the key currency in each cluster were obtained and we found that the clusters matched nicely with the geographical regions of corresponding countries in the world such as Asia or Europe. As expected the key currencies were generally those showing major economic activity.

  6. Effect of standardized training on the reliability of the Cochrane risk of bias assessment tool: a prospective study.

    PubMed

    da Costa, Bruno R; Beckett, Brooke; Diaz, Alison; Resta, Nina M; Johnston, Bradley C; Egger, Matthias; Jüni, Peter; Armijo-Olivo, Susan

    2017-03-03

    The Cochrane risk of bias tool is commonly criticized for having a low reliability. We aimed to investigate whether training of raters, with objective and standardized instructions on how to assess risk of bias, can improve the reliability of the Cochrane risk of bias tool. In this pilot study, four raters inexperienced in risk of bias assessment were randomly allocated to minimal or intensive standardized training for risk of bias assessment of randomized trials of physical therapy treatments for patients with knee osteoarthritis pain. Two raters were experienced risk of bias assessors who served as reference. The primary outcome of our study was between-group reliability, defined as the agreement of the risk of bias assessments of inexperienced raters with the reference assessments of experienced raters. Consensus-based assessments were used for this purpose. The secondary outcome was within-group reliability, defined as the agreement of assessments within pairs of inexperienced raters. We calculated the chance-corrected weighted Kappa to quantify agreement within and between groups of raters for each of the domains of the risk of bias tool. A total of 56 trials were included in our analysis. The Kappa for the agreement of inexperienced raters with reference across items of the risk of bias tool ranged from 0.10 to 0.81 for the minimal training group and from 0.41 to 0.90 for the standardized training group. The Kappa values for the agreement within pairs of inexperienced raters across the items of the risk of bias tool ranged from 0 to 0.38 for the minimal training group and from 0.93 to 1 for the standardized training group. Between-group differences in Kappa for the agreement of inexperienced raters with reference always favored the standardized training group and was most pronounced for incomplete outcome data (difference in Kappa 0.52, p < 0.001) and allocation concealment (difference in Kappa 0.30, p = 0.004). Intensive, standardized training on risk of bias assessment may significantly improve the reliability of the Cochrane risk of bias tool.

  7. Coating for hot sliding seals

    NASA Technical Reports Server (NTRS)

    Stock, J.

    1979-01-01

    Heat resistant paint is effective surface coating for sliding seals that must operate at elevated temperatures. Economical paint is easy to apply, offers minimal friction, and improves reliability of seals.

  8. The Reliability and Effectiveness of a Radar-Based Animal Detection System

    DOT National Transportation Integrated Search

    2017-09-22

    This document contains data on the reliability and effectiveness of an animal detection system along U.S. Hwy 95 near Bonners Ferry, Idaho. The system uses a Doppler radar to detect large mammals (e.g., deer and elk) when they approach the highway. T...

  9. The Reliability and Effectiveness of a Radar-Based Animal Detection System

    DOT National Transportation Integrated Search

    2017-09-01

    This document contains data on the reliability and effectiveness of an animal detection system along U.S. Hwy 95 near Bonners Ferry, Idaho. The system uses a Doppler radar to detect large mammals (e.g., deer and elk) when they approach the highway. T...

  10. Advanced shortwave infrared and Raman hyperspectral sensors for homeland security and law enforcement operations

    NASA Astrophysics Data System (ADS)

    Klueva, Oksana; Nelson, Matthew P.; Gardner, Charles W.; Gomer, Nathaniel R.

    2015-05-01

    Proliferation of chemical and explosive threats as well as illicit drugs continues to be an escalating danger to civilian and military personnel. Conventional means of detecting and identifying hazardous materials often require the use of reagents and/or physical sampling, which is a time-consuming, costly and often dangerous process. Stand-off detection allows the operator to detect threat residues from a safer distance minimizing danger to people and equipment. Current fielded technologies for standoff detection of chemical and explosive threats are challenged by low area search rates, poor targeting efficiency, lack of sensitivity and specificity or use of costly and potentially unsafe equipment such as lasers. A demand exists for stand-off systems that are fast, safe, reliable and user-friendly. To address this need, ChemImage Sensor Systems™ (CISS) has developed reagent-less, non-contact, non-destructive sensors for the real-time detection of hazardous materials based on widefield shortwave infrared (SWIR) and Raman hyperspectral imaging (HSI). Hyperspectral imaging enables automated target detection displayed in the form of image making result analysis intuitive and user-friendly. Application of the CISS' SWIR-HSI and Raman sensing technologies to Homeland Security and Law Enforcement for standoff detection of homemade explosives and illicit drugs and their precursors in vehicle and personnel checkpoints is discussed. Sensing technologies include a portable, robot-mounted and standalone variants of the technology. Test data is shown that supports the use of SWIR and Raman HSI for explosive and drug screening at checkpoints as well as screening for explosives and drugs at suspected clandestine manufacturing facilities.

  11. Simultaneous detection and identification of four cherry viruses by two step multiplex RT-PCR with an internal control of plant nad5 mRNA.

    PubMed

    Noorani, Md Salik; Awasthi, Prachi; Sharma, Maheshwar Prasad; Ram, Raja; Zaidi, Aijaz Asgar; Hallan, Vipin

    2013-10-01

    A multiplex reverse transcription-polymerase chain reaction (mRT-PCR) was developed and standardized for the simultaneous detection of four cherry viruses: Cherry virus A (CVA, Genus; Capillovirus), Cherry necrotic rusty mottle virus (CNRMV, unassigned species of the Betaflexiviridae), Little cherry virus 1 (LChV-1, Genus; Closterovirus) and Prunus necrotic ringspot virus (PNRSV, Genus; Ilarvirus) with nad5 as plant internal control. A reliable and quick method for total plant RNA extraction from pome and stone fruit trees was also developed. To minimize primer dimer formation, a single antisense primer for CVA and CNRMV was used. A mixture of random hexamer and oligo (dT) primer was used for cDNA synthesis, which was highly suited and economic for multiplexing. All four viruses were detected successfully by mRT-PCR in artificially created viral RNA mixture and field samples of sweet cherry. The identity of the viruses was confirmed by sequencing. The assay could detect above viruses in diluted cDNA (10(-4)) and RNA (10(-3), except PNRSV which was detected only till ten times lesser dilution). The developed mRT-PCR will not only be useful for the detection of viruses from single or multiple infections of sweet cherry plants but also for other stone and pome fruits. The developed method will be therefore quite helpful for virus indexing, plant quarantine and certification programs. This is the first report for the simultaneous detection of four cherry viruses by mRT-PCR. Copyright © 2013 Elsevier B.V. All rights reserved.

  12. Test-retest reliability and responsiveness of the Barthel Index-based Supplementary Scales in patients with stroke.

    PubMed

    Lee, Ya-Chen; Yu, Wan-Hui; Hsueh, I-Ping; Chen, Sheng-Shiung; Hsieh, Ching-Lin

    2017-10-01

    A lack of evidence on the test-retest reliability and responsiveness limits the utility of the BI-based Supplementary Scales (BI-SS) in both clinical and research settings. To examine the test-retest reliability and responsiveness of the BI-based Supplementary Scales (BI-SS) in patients with stroke. A repeated-assessments design (1 week apart) was used to examine the test-retest reliability of the BI-SS. For the responsiveness study, the participants were assessed with the BI-SS and BI (treated as an external criterion) at admission to and discharge from rehabilitation wards. Seven outpatient rehabilitation units and one inpatient rehabilitation unit. Outpatients with chronic stroke. Eighty-four outpatients with chronic stroke participated in the test-retest reliability study. Fifty-seven inpatients completed baseline and follow-up assessments in the responsiveness study. For the test-retest reliability study, the values of the intra-class correlation coefficient and the overall percentage of minimal detectable change for the Ability Scale and Self-perceived Difficulty Scale were 0.97, 12.8%, and 0.78, 35.8%, respectively. For the responsiveness study, the standardized effect size and standardized response mean (representing internal responsiveness) of the Ability Scale and Self-perceived Difficulty Scale were 1.17 and 1.56, and 0.78 and 0.89, respectively. Regarding external responsiveness, the change in score of the Ability Scale had significant and moderate association with that of the BI (r=0.61, P<0.001). The change in score of the Self-perceived Difficulty Scale had non-significant and weak association with that of the BI (r=0.23, P=0.080). The Ability Scale of the BI-SS has satisfactory test-retest reliability and sufficient responsiveness for patients with stroke. However, the Self-perceived Difficulty Scale of the BI-SS has substantial random measurement error and insufficient external responsiveness, which may affect its utility in clinical settings. The findings of this study provide empirical evidence of psychometric properties of the BI-SS for assessing ability and self-perceived difficulty of ADL in patients with stroke.

  13. Reliability of dynamometric passive properties of the pelvic floor muscles in postmenopausal women with stress urinary incontinence.

    PubMed

    Morin, Mélanie; Gravel, Denis; Bourbonnais, Daniel; Dumoulin, Chantale; Ouellet, Stéphane

    2008-01-01

    The passive properties of the pelvic floor muscles (PFM) might play a role in stress urinary incontinence (SUI) pathophysiology. To investigate the test-retest reliability of the dynamometric passive properties of the PFM in postmenopausal SUI women. Thirty-two SUI postmenopausal women were convened to two sessions 2 weeks apart. In each session, the measurements were repeated twice. The pelvic floor musculature was evaluated in four different conditions: (1) forces recorded at minimal aperture (initial passive resistance); (2) passive resistance at maximal aperture; (3) five lengthening and shortening cycles (Forces and passive elastic stiffness (PES) were evaluated at different vaginal apertures. Hysteresis was also calculated.); (4) Percentage of passive resistance loss after 1 min of sustained stretching was computed. The generalizability theory was used to calculate two reliability estimates, the dependability indices (Phi) and the standard error of measurement (SEM), for one session involving one measurement or the mean of two measurements. Overall, the reliability of the passive properties was good with indices of dependability of 0.75-0.93. The SEMs for forces and PES were 0.24-0.67 N and 0.03-0.10 N/mm, respectively, for mean, maximal and 20-mm apertures, representing an error between 13% and 23%. Passive forces at minimal aperture showed lower reliability (Phi = 0.51-0.57) compared with other vaginal openings. The aperture at a common force of 0.5 N was the only parameter demonstrating a poor reliability (Phi = 0.35). This new approach for assessing PFM passive properties showed enough reliability for highly recommending its inclusion in the PFM assessment of SUI postmenopausal women. (c) 2008 Wiley-Liss, Inc.

  14. Toward a Common Language for Measuring Patient Mobility in the Hospital: Reliability and Construct Validity of Interprofessional Mobility Measures.

    PubMed

    Hoyer, Erik H; Young, Daniel L; Klein, Lisa M; Kreif, Julie; Shumock, Kara; Hiser, Stephanie; Friedman, Michael; Lavezza, Annette; Jette, Alan; Chan, Kitty S; Needham, Dale M

    2018-02-01

    The lack of common language among interprofessional inpatient clinical teams is an important barrier to achieving inpatient mobilization. In The Johns Hopkins Hospital, the Activity Measure for Post-Acute Care (AM-PAC) Inpatient Mobility Short Form (IMSF), also called "6-Clicks," and the Johns Hopkins Highest Level of Mobility (JH-HLM) are part of routine clinical practice. The measurement characteristics of these tools when used by both nurses and physical therapists for interprofessional communication or assessment are unknown. The purposes of this study were to evaluate the reliability and minimal detectable change of AM-PAC IMSF and JH-HLM when completed by nurses and physical therapists and to evaluate the construct validity of both measures when used by nurses. A prospective evaluation of a convenience sample was used. The test-retest reliability and the interrater reliability of AM-PAC IMSF and JH-HLM for inpatients in the neuroscience department (n = 118) of an academic medical center were evaluated. Each participant was independently scored twice by a team of 2 nurses and 1 physical therapist; a total of 4 physical therapists and 8 nurses participated in reliability testing. In a separate inpatient study protocol (n = 69), construct validity was evaluated via an assessment of convergent validity with other measures of function (grip strength, Katz Activities of Daily Living Scale, 2-minute walk test, 5-times sit-to-stand test) used by 5 nurses. The test-retest reliability values (intraclass correlation coefficients) for physical therapists and nurses were 0.91 and 0.97, respectively, for AM-PAC IMSF and 0.94 and 0.95, respectively, for JH-HLM. The interrater reliability values (intraclass correlation coefficients) between physical therapists and nurses were 0.96 for AM-PAC IMSF and 0.99 for JH-HLM. Construct validity (Spearman correlations) ranged from 0.25 between JH-HLM and right-hand grip strength to 0.80 between AM-PAC IMSF and the Katz Activities of Daily Living Scale. The results were obtained from inpatients in the neuroscience department of a single hospital. The AM-PAC IMSF and JH-HLM had excellent interrater reliability and test-retest reliability for both physical therapists and nurses. The evaluation of convergent validity suggested that AM-PAC IMSF and JH-HLM measured constructs of patient mobility and physical functioning. © 2017 American Physical Therapy Association

  15. A numerical insight into elastomer normally closed micro valve actuation with cohesive interfacial cracking modelling

    NASA Astrophysics Data System (ADS)

    Wang, Dongyang; Ba, Dechun; Hao, Ming; Duan, Qihui; Liu, Kun; Mei, Qi

    2018-05-01

    Pneumatic NC (normally closed) valves are widely used in high density microfluidics systems. To improve actuation reliability, the actuation pressure needs to be reduced. In this work, we utilize 3D FEM (finite element method) modelling to get an insight into the valve actuation process numerically. Specifically, the progressive debonding process at the elastomer interface is simulated with CZM (cohesive zone model) method. To minimize the actuation pressure, the V-shape design has been investigated and compared with a normal straight design. The geometrical effects of valve shape has been elaborated, in terms of valve actuation pressure. Based on our simulated results, we formulate the main concerns for micro valve design and fabrication, which is significant for minimizing actuation pressures and ensuring reliable operation.

  16. Motion-insensitive carotid intraplaque hemorrhage imaging using 3D inversion recovery preparation stack of stars (IR-prep SOS) technique.

    PubMed

    Kim, Seong-Eun; Roberts, John A; Eisenmenger, Laura B; Aldred, Booth W; Jamil, Osama; Bolster, Bradley D; Bi, Xiaoming; Parker, Dennis L; Treiman, Gerald S; McNally, J Scott

    2017-02-01

    Carotid artery imaging is important in the clinical management of patients at risk for stroke. Carotid intraplaque hemorrhage (IPH) presents an important diagnostic challenge. 3D magnetization prepared rapid acquisition gradient echo (MPRAGE) has been shown to accurately image carotid IPH; however, this sequence can be limited due to motion- and flow-related artifact. The purpose of this work was to develop and evaluate an improved 3D carotid MPRAGE sequence for IPH detection. We hypothesized that a radial-based k-space trajectory sequence such as "Stack of Stars" (SOS) incorporated with inversion recovery preparation would offer reduced motion sensitivity and more robust flow suppression by oversampling of central k-space. A total of 31 patients with carotid disease (62 carotid arteries) were imaged at 3T magnetic resonance imaging (MRI) with 3D IR-prep Cartesian and SOS sequences. Image quality was determined between SOS and Cartesian MPRAGE in 62 carotid arteries using t-tests and multivariable linear regression. Kappa analysis was used to determine interrater reliability. In all, 25 among 62 carotid plaques had carotid IPH by consensus from the reviewers on SOS compared to 24 on Cartesian sequence. Image quality was significantly higher with SOS compared to Cartesian (mean 3.74 vs. 3.11, P < 0.001). SOS acquisition yielded sharper image features with less motion (19.4% vs. 45.2%, P < 0.002) and flow artifact (27.4% vs. 41.9%, P < 0.089). There was also excellent interrater reliability with SOS (kappa = 0.89), higher than that of Cartesian (kappa = 0.84). By minimizing flow and motion artifacts and retaining high interrater reliability, the SOS MPRAGE has important advantages over Cartesian MPRAGE in carotid IPH detection. 1 J. Magn. Reson. Imaging 2017;45:410-417. © 2016 International Society for Magnetic Resonance in Medicine.

  17. Detection of tiny amounts of fissile materials in large-sized containers with radioactive waste

    NASA Astrophysics Data System (ADS)

    Batyaev, V. F.; Skliarov, S. V.

    2018-01-01

    The paper is devoted to non-destructive control of tiny amounts of fissile materials in large-sized containers filled with radioactive waste (RAW). The aim of this work is to model an active neutron interrogation facility for detection of fissile ma-terials inside NZK type containers with RAW and determine the minimal detectable mass of U-235 as a function of various param-eters: matrix type, nonuniformity of container filling, neutron gen-erator parameters (flux, pulse frequency, pulse duration), meas-urement time. As a result the dependence of minimal detectable mass on fissile materials location inside container is shown. Nonu-niformity of the thermal neutron flux inside a container is the main reason of the space-heterogeneity of minimal detectable mass in-side a large-sized container. Our experiments with tiny amounts of uranium-235 (<1 g) confirm the detection of fissile materials in NZK containers by using active neutron interrogation technique.

  18. Accuracy and reliability of forensic latent fingerprint decisions

    PubMed Central

    Ulery, Bradford T.; Hicklin, R. Austin; Buscaglia, JoAnn; Roberts, Maria Antonia

    2011-01-01

    The interpretation of forensic fingerprint evidence relies on the expertise of latent print examiners. The National Research Council of the National Academies and the legal and forensic sciences communities have called for research to measure the accuracy and reliability of latent print examiners’ decisions, a challenging and complex problem in need of systematic analysis. Our research is focused on the development of empirical approaches to studying this problem. Here, we report on the first large-scale study of the accuracy and reliability of latent print examiners’ decisions, in which 169 latent print examiners each compared approximately 100 pairs of latent and exemplar fingerprints from a pool of 744 pairs. The fingerprints were selected to include a range of attributes and quality encountered in forensic casework, and to be comparable to searches of an automated fingerprint identification system containing more than 58 million subjects. This study evaluated examiners on key decision points in the fingerprint examination process; procedures used operationally include additional safeguards designed to minimize errors. Five examiners made false positive errors for an overall false positive rate of 0.1%. Eighty-five percent of examiners made at least one false negative error for an overall false negative rate of 7.5%. Independent examination of the same comparisons by different participants (analogous to blind verification) was found to detect all false positive errors and the majority of false negative errors in this study. Examiners frequently differed on whether fingerprints were suitable for reaching a conclusion. PMID:21518906

  19. Accuracy and reliability of forensic latent fingerprint decisions.

    PubMed

    Ulery, Bradford T; Hicklin, R Austin; Buscaglia, Joann; Roberts, Maria Antonia

    2011-05-10

    The interpretation of forensic fingerprint evidence relies on the expertise of latent print examiners. The National Research Council of the National Academies and the legal and forensic sciences communities have called for research to measure the accuracy and reliability of latent print examiners' decisions, a challenging and complex problem in need of systematic analysis. Our research is focused on the development of empirical approaches to studying this problem. Here, we report on the first large-scale study of the accuracy and reliability of latent print examiners' decisions, in which 169 latent print examiners each compared approximately 100 pairs of latent and exemplar fingerprints from a pool of 744 pairs. The fingerprints were selected to include a range of attributes and quality encountered in forensic casework, and to be comparable to searches of an automated fingerprint identification system containing more than 58 million subjects. This study evaluated examiners on key decision points in the fingerprint examination process; procedures used operationally include additional safeguards designed to minimize errors. Five examiners made false positive errors for an overall false positive rate of 0.1%. Eighty-five percent of examiners made at least one false negative error for an overall false negative rate of 7.5%. Independent examination of the same comparisons by different participants (analogous to blind verification) was found to detect all false positive errors and the majority of false negative errors in this study. Examiners frequently differed on whether fingerprints were suitable for reaching a conclusion.

  20. Reliability and Validity of the Pain Anxiety Symptom Scale in Persian Speaking Chronic Low Back Pain Patients.

    PubMed

    Shanbehzadeh, Sanaz; Salavati, Mahyar; Tavahomi, Mahnaz; Khatibi, Ali; Talebian, Saeed; Khademi-Kalantari, Khosro

    2017-11-01

    Psychometric testing of the Persian version of Pain Anxiety Symptom Scale 20. The aim of this study was to assess the reliability and construct validity of the PASS-20 in nonspecific chronic low back pain (LBP) patients. The PASS-20 is a self-report questionnaire that assesses pain-related anxiety. The Psychometric properties of this instrument have not been assessed in Persian-speaking chronic LBP patients. One hundred and sixty participants with chronic LBP completed the Persian version of PASS-20, Tampa Scale of Kinesiophobia (TSK), Fear-Avoidance Beliefs Questionnaire (FABQ), Pain Catastrophizing Scale (PCS), trait form of the State-Trait Anxiety (STAI-T), Oswestry Low Back Pain Disability Index (ODI), Beck Depression Inventory (BDI-II), and Visual Analogue Scale (VAS). To evaluate test-retest reliability, 60 patients filled out the PASS-20, 6 to 8 days after the first visit. Test-retest reliability (intraclass correlation coefficient [ICC], standard error of measurement [SEM], and minimal detectable change [MDC]), internal consistency, dimensionality, and construct validity were examined. The ICCs of the PASS-20 subscales and total score ranged from 0.71 to 0.8. The SEMs for PASS-20 total score was 7.29 and for the subscales ranged from 2.43 to 2.98. The MDC for the total score was 20.14 and for the subscales ranged from 6.71 to 8.23. The Cronbach alpha values for the subscales and total score ranged from 0.70 to 0.91. Significant positive correlations were found between the PASS-20 total score and PCS, TSK, FABQ, ODI, BDI, STAI-T, and pain intensity. The Persian version of the PASS-20 showed acceptable psychometric properties for the assessment of pain-related anxiety in Persian-speaking patients with chronic LBP. 3.

  1. Reliability, Validity, and Sensitivity of a Novel Smartphone-Based Eccentric Hamstring Strength Test in Professional Football Players.

    PubMed

    Lee, Justin W Y; Cai, Ming-Jing; Yung, Patrick S H; Chan, Kai-Ming

    2018-05-01

    To evaluate the test-retest reliability, sensitivity, and concurrent validity of a smartphone-based method for assessing eccentric hamstring strength among male professional football players. A total of 25 healthy male professional football players performed the Chinese University of Hong Kong (CUHK) Nordic break-point test, hamstring fatigue protocol, and isokinetic hamstring strength test. The CUHK Nordic break-point test is based on a Nordic hamstring exercise. The Nordic break-point angle was defined as the maximum point where the participant could no longer support the weight of his body against gravity. The criterion for the sensitivity test was the presprinting and postsprinting difference of the Nordic break-point angle with a hamstring fatigue protocol. The hamstring fatigue protocol consists of 12 repetitions of the 30-m sprint with 30-s recoveries between sprints. Hamstring peak torque of the isokinetic hamstring strength test was used as the criterion for validity. A high test-retest reliability (intraclass correlation coefficient = .94; 95% confidence interval, .82-.98) was found in the Nordic break-point angle measurements. The Nordic break-point angle significantly correlated with isokinetic hamstring peak torques at eccentric action of 30°/s (r = .88, r 2  = .77, P < .001). The minimal detectable difference was 8.03°. The sensitivity of the measure was good enough that a significance difference (effect size = 0.70, P < .001) was found between presprinting and postsprinting values. The CUHK Nordic break-point test is a simple, portable, quick smartphone-based method to provide reliable and accurate eccentric hamstring strength measures among male professional football players.

  2. Short-distance walking speed tests in people with Parkinson disease: reliability, responsiveness, and validity.

    PubMed

    Combs, Stephanie A; Diehl, M Dyer; Filip, Jacqueline; Long, Erin

    2014-02-01

    The aims of this study were to determine test-retest reliability and responsiveness of short-distance walking speed tests for persons with Parkinson disease (PD). Discriminant and convergent validity of walking speed tests were also examined. Eighty-eight participants with PD (mean age, 66 years) with mild to moderate severity (stages 1-4 on the Hoehn and Yahr Scale) were tested on medications. Measures of activity included the comfortable and fast 10-m walk tests (CWT, FWT), 6-min walk test (6MWT), mini balance evaluations systems test (mini-BEST Test), fear of falling (FoF), and the Activity-Specific Balance Confidence Scale (ABC). The mobility subsection of the PD quality of life-39 (PDQ39-M) served as a participation-based measure. Test-retest reliability was high for both walking speed measures (CWT, ICC(2,1) = 0.98; FWT, ICC(2,1) = 0.99). Minimal detectable change (MDC(95)) for the CWT and FWT was 0.09 m/s and 0.13 m/s respectively. Participants at Hoehn & Yahr levels 3/4 demonstrated significantly slower walking speed with the CWT and FWT than participants at Hoehn & Yahr levels 1 and 2 (P < .01). The CWT and FWT were both significantly (P ≤ .002) correlated with all activity and participation-based measures. Short-distance walking speed tests are clinically useful measures for persons with PD. The CWT and FWT are highly reliable and responsive to change in persons with PD. Short distance walking speed can be used to discriminate differences in gait function between persons with mild and moderate PD severity. The CWT and FWT had moderate to strong associations with other activity and participation based measures demonstrating convergent validity. Copyright © 2013 Elsevier B.V. All rights reserved.

  3. Inter- and intrarater reliability of two proprioception tests using clinical applicable measurement tools in subjects with and without knee osteoarthritis.

    PubMed

    Baert, Isabel A C; Lluch, Enrique; Struyf, Thomas; Peeters, Greta; Van Oosterwijck, Sophie; Tuynman, Joanna; Rufai, Salim; Struyf, Filip

    2018-06-01

    The therapeutic value of proprioceptive-based exercises in knee osteoarthritis (KOA) management warrants investigation of proprioceptive testing methods easily accessible in clinical practice. To estimate inter- and intrarater reliability of the knee joint position sense (KJPS) test and knee force sense (KFS) test in subjects with and without KOA. Cross-sectional test-retest design. Two blinded raters performed independently repeated measures of the KJPS and KFS test, using an analogue inclinometer and handheld dynamometer, respectively, in eight KOA patients (12 symptomatic knees) and 26 healthy controls (52 asymptomatic knees). Intraclass correlation coefficients (ICCs; model 2,1), standard error of measurement (SEM) and minimal detectable change with 95% confidence bounds (MDC 95 ) were calculated. For KJPS, results showed good to excellent test-retest agreement (ICCs 0.70-0.95 in KOA patients; ICCs 0.65-0.85 in healthy controls). A 2° measurement error (SEM 1°) was reported when measuring KJPS in multiple test positions and calculating mean repositioning error. Testing KOA patients pre and post therapy a repositioning error larger than 4° (MDC 95 ) is needed to consider true change. Measuring KFS using handheld dynamometry showed poor to fair interrater and poor to excellent intrarater reliability in subjects with and without KOA. Measuring KJPS in multiple test positions using an analogue inclinometer and calculating mean repositioning error is reliable and can be used in clinical practice. We do not recommend the use of the KFS test to clinicians. Further research is required to establish diagnostic accuracy and validity of our KJPS test in larger knee pain populations. Copyright © 2017 Elsevier Ltd. All rights reserved.

  4. Validity and reliability problems with patient global as a component of the ACR/EULAR remission criteria as used in clinical practice.

    PubMed

    Masri, Karim R; Shaver, Timothy S; Shahouri, Shadi H; Wang, Shirley; Anderson, James D; Busch, Ruth E; Michaud, Kaleb; Mikuls, Ted R; Caplan, Liron; Wolfe, Frederick

    2012-06-01

    To investigate what factors influence patient global health assessment (PtGlobal), and how those factors and the reliability of PtGlobal affect the rate, reliability, and validity of recently published American College of Rheumatology/European League Against Rheumatism (ACR/EULAR) rheumatoid arthritis (RA) remission criteria when used in clinical practice. We examined consecutive patients with RA in clinical practice and identified 77 who met ACR/EULAR joint criteria for remission (≤ 1 swollen joint and ≤ 1 tender joint). We evaluated factors associated with a PtGlobal > 1, because a PtGlobal ≤ 1 defined ACR/EULAR remission in this group of patients who had already met ACR/EULAR joint criteria. Of the 77 patients examined, only 17 (22.1%) had PtGlobal ≤ 1 and thus fully satisfied ACR/EULAR criteria. A large proportion of patients not in remission by ACR/EULAR criteria had high PtGlobal related to noninflammatory issues, including low back pain, fatigue, and functional limitations, and a number of patients clustered in the range of PtGlobal > 1 and ≤ 2. However, the minimal detectable difference for PtGlobal was 2.3. In addition, compared with a PtGlobal severity score, a PtGlobal activity score was 3.3% less likely to be abnormal (> 1). Noninflammatory factors contribute to the level of PtGlobal and result in the exclusion of many patients who would otherwise be in "true" remission according to the ACR/EULAR definition. Reliability problems associated with PtGlobal can also result in misclassification, and may explain the observation of low longterm remission rates in RA. As currently constituted, the use of the ACR/EULAR remission criteria in clinical practice appears to be problematic.

  5. Reliability, Validity, and Responsiveness of the Incremental Shuttle Walk Test in Patients With Interstitial Lung Disease.

    PubMed

    Singh, Sumedha; Moiz, Jamal Ali; Ali, Mir Shad; Talwar, Deepak

    2018-05-11

    To determine the reliability, validity, and responsiveness of the incremental shuttle walk test (ISWT) in patients with interstitial lung disease (ILD). This was a cross-sectional longitudinal study. Patients (n = 27, 10 males; mean age ± SD, 61 ± 9.8 y) with ILD of any etiology, who participated in an outpatient pulmonary rehabilitation (PR) program, were recruited. Reliability was determined by comparing the distance covered in meters between the ISWT-1 and the ISWT-2. Validity was assessed by correlating the distance covered in the ISWT-1, with the maximum oxygen consumption (VO2max) obtained through cardiopulmonary exercise testing and distance covered during the 6-min walk test (6MWT). Responsiveness was assessed by comparing the distance covered in the ISWT-3, undertaken after the completion of PR, to the ISWT-1. The distance covered was equivalent between the ISWT-1 (216.7 ± 64.9 m) and the ISWT-2 (220.7 ± 67.3 m), with an excellent intraclass correlation coefficient (ICC2,1 = 0.91; 95% CI, 0.81-0.95). The standard error of measurement and minimal detectable change at the 95% CI (MDC95) values for the ISWT were 19.5 m and 53.9m, respectively. There were significant correlations between the distance covered on the ISWT and VO2max (r = 0.79, P < .0001) and the distance covered on the 6MWT (r = 0.76, P < .0001). Following PR, the change in the ISWT distance showed large effect size (ES = 0.85) and standardized response mean (SRM = 1.58). The ISWT is a reliable, valid, and responsive measure of estimated functional capacity in patients with ILD.

  6. An integrated platform for assessing biologics (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Schein, Perry; O'Dell, Dakota; Erickson, David

    2016-04-01

    Protein therapeutics are a rapidly growing portion of the pharmaceuticals market and have many significant advantages over traditional small molecule drugs. As this market expands, however, critical regulatory and quality control issues remain, most notably the problem of protein aggregation. Individual target proteins often aggregate into larger masses which trigger an immune response in the body, which can reduce the efficacy of the drug for its intended purpose, or cause serious anaphylactic side-effects. Although detecting and minimizing aggregate formation is critical to ensure an effective product, aggregation dynamics are often highly complicated and there is little hope of reliable prediction and prevention from first principles. This problem is compounded for aggregates in the subvisible range of 100 nm to 10 micrometers where traditional techniques for detecting aggregates have significant limitations. Here, we present an integrated optofluidic platform for detecting nanoscale protein aggregates and characterizing interactions between these aggregates and a reference surface. By delivering light to a solution of proteins with an optical waveguide, scattered light from individual protein aggregates can be detected and analyzed to determine the force profile between each particle and the waveguide surface. Unlike existing methods which only determine size or charge, our label-free screening technique can directly measure the surface interaction forces between single aggregates and the glass substrate. This direct measurement capability may allow for better empirical predictions of the stability of protein aggregates during drug manufacturing and storage.

  7. Space Shuttle Rudder Speed Brake Actuator-A Case Study Probabilistic Fatigue Life and Reliability Analysis

    NASA Technical Reports Server (NTRS)

    Oswald, Fred B.; Savage, Michael; Zaretsky, Erwin V.

    2015-01-01

    The U.S. Space Shuttle fleet was originally intended to have a life of 100 flights for each vehicle, lasting over a 10-year period, with minimal scheduled maintenance or inspection. The first space shuttle flight was that of the Space Shuttle Columbia (OV-102), launched April 12, 1981. The disaster that destroyed Columbia occurred on its 28th flight, February 1, 2003, nearly 22 years after its first launch. In order to minimize risk of losing another Space Shuttle, a probabilistic life and reliability analysis was conducted for the Space Shuttle rudder/speed brake actuators to determine the number of flights the actuators could sustain. A life and reliability assessment of the actuator gears was performed in two stages: a contact stress fatigue model and a gear tooth bending fatigue model. For the contact stress analysis, the Lundberg-Palmgren bearing life theory was expanded to include gear-surface pitting for the actuator as a system. The mission spectrum of the Space Shuttle rudder/speed brake actuator was combined into equivalent effective hinge moment loads including an actuator input preload for the contact stress fatigue and tooth bending fatigue models. Gear system reliabilities are reported for both models and their combination. Reliability of the actuator bearings was analyzed separately, based on data provided by the actuator manufacturer. As a result of the analysis, the reliability of one half of a single actuator was calculated to be 98.6 percent for 12 flights. Accordingly, each actuator was subsequently limited to 12 flights before removal from service in the Space Shuttle.

  8. A study of fault prediction and reliability assessment in the SEL environment

    NASA Technical Reports Server (NTRS)

    Basili, Victor R.; Patnaik, Debabrata

    1986-01-01

    An empirical study on estimation and prediction of faults, prediction of fault detection and correction effort, and reliability assessment in the Software Engineering Laboratory environment (SEL) is presented. Fault estimation using empirical relationships and fault prediction using curve fitting method are investigated. Relationships between debugging efforts (fault detection and correction effort) in different test phases are provided, in order to make an early estimate of future debugging effort. This study concludes with the fault analysis, application of a reliability model, and analysis of a normalized metric for reliability assessment and reliability monitoring during development of software.

  9. Review of Reliability-Based Design Optimization Approach and Its Integration with Bayesian Method

    NASA Astrophysics Data System (ADS)

    Zhang, Xiangnan

    2018-03-01

    A lot of uncertain factors lie in practical engineering, such as external load environment, material property, geometrical shape, initial condition, boundary condition, etc. Reliability method measures the structural safety condition and determine the optimal design parameter combination based on the probabilistic theory. Reliability-based design optimization (RBDO) is the most commonly used approach to minimize the structural cost or other performance under uncertainty variables which combines the reliability theory and optimization. However, it cannot handle the various incomplete information. The Bayesian approach is utilized to incorporate this kind of incomplete information in its uncertainty quantification. In this paper, the RBDO approach and its integration with Bayesian method are introduced.

  10. Reliability Estimation of Parameters of Helical Wind Turbine with Vertical Axis

    PubMed Central

    Dumitrascu, Adela-Eliza; Lepadatescu, Badea; Dumitrascu, Dorin-Ion; Nedelcu, Anisor; Ciobanu, Doina Valentina

    2015-01-01

    Due to the prolonged use of wind turbines they must be characterized by high reliability. This can be achieved through a rigorous design, appropriate simulation and testing, and proper construction. The reliability prediction and analysis of these systems will lead to identifying the critical components, increasing the operating time, minimizing failure rate, and minimizing maintenance costs. To estimate the produced energy by the wind turbine, an evaluation approach based on the Monte Carlo simulation model is developed which enables us to estimate the probability of minimum and maximum parameters. In our simulation process we used triangular distributions. The analysis of simulation results has been focused on the interpretation of the relative frequency histograms and cumulative distribution curve (ogive diagram), which indicates the probability of obtaining the daily or annual energy output depending on wind speed. The experimental researches consist in estimation of the reliability and unreliability functions and hazard rate of the helical vertical axis wind turbine designed and patented to climatic conditions for Romanian regions. Also, the variation of power produced for different wind speeds, the Weibull distribution of wind probability, and the power generated were determined. The analysis of experimental results indicates that this type of wind turbine is efficient at low wind speed. PMID:26167524

  11. Reliability Estimation of Parameters of Helical Wind Turbine with Vertical Axis.

    PubMed

    Dumitrascu, Adela-Eliza; Lepadatescu, Badea; Dumitrascu, Dorin-Ion; Nedelcu, Anisor; Ciobanu, Doina Valentina

    2015-01-01

    Due to the prolonged use of wind turbines they must be characterized by high reliability. This can be achieved through a rigorous design, appropriate simulation and testing, and proper construction. The reliability prediction and analysis of these systems will lead to identifying the critical components, increasing the operating time, minimizing failure rate, and minimizing maintenance costs. To estimate the produced energy by the wind turbine, an evaluation approach based on the Monte Carlo simulation model is developed which enables us to estimate the probability of minimum and maximum parameters. In our simulation process we used triangular distributions. The analysis of simulation results has been focused on the interpretation of the relative frequency histograms and cumulative distribution curve (ogive diagram), which indicates the probability of obtaining the daily or annual energy output depending on wind speed. The experimental researches consist in estimation of the reliability and unreliability functions and hazard rate of the helical vertical axis wind turbine designed and patented to climatic conditions for Romanian regions. Also, the variation of power produced for different wind speeds, the Weibull distribution of wind probability, and the power generated were determined. The analysis of experimental results indicates that this type of wind turbine is efficient at low wind speed.

  12. Branch and bound algorithm for accurate estimation of analytical isotropic bidirectional reflectance distribution function models.

    PubMed

    Yu, Chanki; Lee, Sang Wook

    2016-05-20

    We present a reliable and accurate global optimization framework for estimating parameters of isotropic analytical bidirectional reflectance distribution function (BRDF) models. This approach is based on a branch and bound strategy with linear programming and interval analysis. Conventional local optimization is often very inefficient for BRDF estimation since its fitting quality is highly dependent on initial guesses due to the nonlinearity of analytical BRDF models. The algorithm presented in this paper employs L1-norm error minimization to estimate BRDF parameters in a globally optimal way and interval arithmetic to derive our feasibility problem and lower bounding function. Our method is developed for the Cook-Torrance model but with several normal distribution functions such as the Beckmann, Berry, and GGX functions. Experiments have been carried out to validate the presented method using 100 isotropic materials from the MERL BRDF database, and our experimental results demonstrate that the L1-norm minimization provides a more accurate and reliable solution than the L2-norm minimization.

  13. Optical clearing of articular cartilage: a comparison of clearing agents

    NASA Astrophysics Data System (ADS)

    Bykov, Alexander; Hautala, Tapio; Kinnunen, Matti; Popov, Alexey; Karhula, Sakari; Saarakkala, Simo; Nieminen, Miika T.; Tuchin, Valery

    2015-07-01

    Optical clearing technique was applied to the problem of OCT imaging of articular cartilage and subchondral bone. We show that optical clearing significantly enhances visualization of articular cartilage and cartilage-bone interface. The effect of different clearing agents was analyzed. For the clearing, iohexol solution and propylene glycol (PG) were used. Clearing was performed in vitro at room temperature by immersion method. Cylindrical osteochondral samples (d=4.8mm) were drilled from bovine lateral femur and stored in phosphate-buffered saline at -20°C until clearing. Monitoring of clearing process was performed using high-speed spectral-domain OCT system providing axial resolution of 5.8μm at 930nm. Total duration of experiment was 90-100min to ensure saturation of clearing. We have shown that iohexol solution and PG are capable to optically clear articular cartilage enabling reliable characterization of cartilagebone interface with OCT. Being a low osmolarity agent, iohexol provides minimal changes to the thickness of cartilage sample. Clearing saturation time for the cartilage sample with the thickness of 0.9 mm measured with OCT is of 50 min. However, less than 15 min is enough to reliably detect the rear cartilage boundary. Alternatively, PG significantly (60%) reduces the cartilage thickness enabling better visualization of subchondral bone. It was observed that PG has higher clearing rate. The clearing saturation time is of 30 min, however less than 5 min is enough to detect cartilage-bone interface. We conclude that iohexol solution is superior for OCT imaging of cartilage and cartilage-bone interface, while PG suits better for subhondral bone visualization.

  14. Assessment of Anaerobic Toluene Biodegradation Activity by bssA Transcript/Gene Ratios

    PubMed Central

    Brow, Christina N.; O'Brien Johnson, Reid; Johnson, Richard L.

    2013-01-01

    Benzylsuccinate synthase (bssA) genes associated with toluene degradation were profiled across a groundwater contaminant plume under nitrate-reducing conditions and were detected in significant numbers throughout the plume. However, differences between groundwater and core sediment samples suggested that microbial transport, rather than local activity, was the underlying cause of the high copy numbers within the downgradient plume. Both gene transcript and reactant concentrations were consistent with this hypothesis. Expression of bssA genes from denitrifying toluene degraders was induced by toluene but only in the presence of nitrate, and transcript abundance dropped rapidly following the removal of either toluene or nitrate. The drop in bssA transcripts following the removal of toluene could be described by an exponential decay function with a half-life on the order of 1 h. Interestingly, bssA transcripts never disappeared completely but were always detected at some level if either inducer was present. Therefore, the detection of transcripts alone may not be sufficient evidence for contaminant degradation. To avoid mistakenly associating basal-level gene expression with actively degrading microbial populations, an integrated approach using the ratio of functional gene transcripts to gene copies is recommended. This approach minimizes the impact of microbial transport on activity assessment and allows reliable assessments of microbial activity to be obtained from water samples. PMID:23811506

  15. BEAMing and Droplet Digital PCR Analysis of Mutant IDH1 mRNA in Glioma Patient Serum and Cerebrospinal Fluid Extracellular Vesicles

    PubMed Central

    Chen, Walter W; Balaj, Leonora; Liau, Linda M; Samuels, Michael L; Kotsopoulos, Steve K; Maguire, Casey A; LoGuidice, Lori; Soto, Horacio; Garrett, Matthew; Zhu, Lin Dan; Sivaraman, Sarada; Chen, Clark; Wong, Eric T; Carter, Bob S; Hochberg, Fred H; Breakefield, Xandra O; Skog, Johan

    2013-01-01

    Development of biofluid-based molecular diagnostic tests for cancer is an important step towards tumor characterization and real-time monitoring in a minimally invasive fashion. Extracellular vesicles (EVs) are released from tumor cells into body fluids and can provide a powerful platform for tumor biomarkers because they carry tumor proteins and nucleic acids. Detecting rare point mutations in the background of wild-type sequences in biofluids such as blood and cerebrospinal fluid (CSF) remains a major challenge. Techniques such as BEAMing (beads, emulsion, amplification, magnetics) PCR and droplet digital PCR (ddPCR) are substantially more sensitive than many other assays for mutant sequence detection. Here, we describe a novel approach that combines biofluid EV RNA and BEAMing RT-PCR (EV-BEAMing), as well droplet digital PCR to interrogate mutations from glioma tumors. EVs from CSF of patients with glioma were shown to contain mutant IDH1 transcripts, and we were able to reliably detect and quantify mutant and wild-type IDH1 RNA transcripts in CSF of patients with gliomas. EV-BEAMing and EV-ddPCR represent a valuable new strategy for cancer diagnostics, which can be applied to a variety of biofluids and neoplasms. PMID:23881452

  16. Monitoring of pipeline ruptures by means of a Robust Satellite Technique (RST)

    NASA Astrophysics Data System (ADS)

    Filizzola, C.; Baldassarre, G.; Corrado, R.; Mazzeo, G.; Marchese, F.; Paciello, R.; Pergola, N.; Tramutoli, V.

    2009-04-01

    Pipeline ruptures have deep economic and ecologic consequences so that pipeline networks represent critical infrastructures to be carefully monitored particularly in areas which are frequently affected by natural disasters like earthquakes, hurricanes, landslide, etc. In order to minimize damages, the detection of harmful events along pipelines should be as rapid as possible and, at the same time, what is detected should be an actual incident and not a false alarm. In this work, a Robust Satellite Technique (RST), already applied to the prevision and NRT (Near Real Time) monitoring of major natural and environmental hazards (such as seismically active areas, volcanic activity, hydrological risk, forest fires and oil spills) has been employed to automatically identify, from satellite, anomalous Thermal Infrared (TIR) transients related to explosions of oil/gas pipelines. In this context, the combination of the RST approach with high temporal resolution, offered by geostationary satellites, seems to assure both a reliable and timely detection of such events. The potentials of the technique (applied to MSG-SEVIRI data) were tested over Iraq, a region which is sadly known for the numerous (mainly manmade) accidents to pipelines, in order to have a simulation of the effects (such as fires or explosions near or directly involving a pipeline facility) due to natural disasters.

  17. Automatic RST-based system for a rapid detection of man-made disasters

    NASA Astrophysics Data System (ADS)

    Tramutoli, Valerio; Corrado, Rosita; Filizzola, Carolina; Livia Grimaldi, Caterina Sara; Mazzeo, Giuseppe; Marchese, Francesco; Pergola, Nicola

    2010-05-01

    Man-made disasters may cause injuries to citizens and damages to critical infrastructures. When it is not possible to prevent or foresee such disasters it is hoped at least to rapidly detect the accident in order to intervene as soon as possible to minimize damages. In this context, the combination of a Robust Satellite Technique (RST), able to identify for sure actual (i.e. no false alarm) accidents, and satellite sensors with high temporal resolution seems to assure both a reliable and a timely detection of abrupt Thermal Infrared (TIR) transients related to dangerous explosions. A processing chain, based on the RST approach, has been developed in the framework of the GMOSS and G-MOSAIC projects by DIFA-UNIBAS team, suitable for automatically identify on MSG-SEVIRI images harmful events. Maps of thermal anomalies are generated every 15 minutes (i.e. SEVIRI temporal repetition rate) over a selected area together with kml files (containing information on latitude and longitude of "thermally" anomalous SEVIRI pixel centre, time of image acquisition, relative intensity of anomalies, etc.) for a rapid visualization of the accident position even on Google Earth. Results achieved in the cases of gas pipelines recently exploded or attacked in Russia and in Iraq will be presented in this work.

  18. Proactive replica checking to assure reliability of data in cloud storage with minimum replication

    NASA Astrophysics Data System (ADS)

    Murarka, Damini; Maheswari, G. Uma

    2017-11-01

    The two major issues for cloud storage systems are data reliability and storage costs. For data reliability protection, multi-replica replication strategy which is used mostly in current clouds acquires huge storage consumption, leading to a large storage cost for applications within the loud specifically. This paper presents a cost-efficient data reliability mechanism named PRCR to cut back the cloud storage consumption. PRCR ensures data reliability of large cloud information with the replication that might conjointly function as a price effective benchmark for replication. The duplication shows that when resembled to the standard three-replica approach, PRCR will scale back to consume only a simple fraction of the cloud storage from one-third of the storage, thence considerably minimizing the cloud storage price.

  19. Reliability analysis and fault-tolerant system development for a redundant strapdown inertial measurement unit. [inertial platforms

    NASA Technical Reports Server (NTRS)

    Motyka, P.

    1983-01-01

    A methodology is developed and applied for quantitatively analyzing the reliability of a dual, fail-operational redundant strapdown inertial measurement unit (RSDIMU). A Markov evaluation model is defined in terms of the operational states of the RSDIMU to predict system reliability. A 27 state model is defined based upon a candidate redundancy management system which can detect and isolate a spectrum of failure magnitudes. The results of parametric studies are presented which show the effect on reliability of the gyro failure rate, both the gyro and accelerometer failure rates together, false alarms, probability of failure detection, probability of failure isolation, and probability of damage effects and mission time. A technique is developed and evaluated for generating dynamic thresholds for detecting and isolating failures of the dual, separated IMU. Special emphasis is given to the detection of multiple, nonconcurrent failures. Digital simulation time histories are presented which show the thresholds obtained and their effectiveness in detecting and isolating sensor failures.

  20. Reliable and energy-efficient communications for wireless biomedical implant systems.

    PubMed

    Ntouni, Georgia D; Lioumpas, Athanasios S; Nikita, Konstantina S

    2014-11-01

    Implant devices are used to measure biological parameters and transmit their results to remote off-body devices. As implants are characterized by strict requirements on size, reliability, and power consumption, applying the concept of cooperative communications to wireless body area networks offers several benefits. In this paper, we aim to minimize the power consumption of the implant device by utilizing on-body wearable devices, while providing the necessary reliability in terms of outage probability and bit error rate. Taking into account realistic power considerations and wireless propagation environments based on the IEEE P802.l5 channel model, an exact theoretical analysis is conducted for evaluating several communication scenarios with respect to the position of the wearable device and the motion of the human body. The derived closed-form expressions are employed toward minimizing the required transmission power, subject to a minimum quality-of-service requirement. In this way, the complexity and power consumption are transferred from the implant device to the on-body relay, which is an efficient approach since they can be easily replaced, in contrast to the in-body implants.

  1. Girsanov's transformation based variance reduced Monte Carlo simulation schemes for reliability estimation in nonlinear stochastic dynamics

    NASA Astrophysics Data System (ADS)

    Kanjilal, Oindrila; Manohar, C. S.

    2017-07-01

    The study considers the problem of simulation based time variant reliability analysis of nonlinear randomly excited dynamical systems. Attention is focused on importance sampling strategies based on the application of Girsanov's transformation method. Controls which minimize the distance function, as in the first order reliability method (FORM), are shown to minimize a bound on the sampling variance of the estimator for the probability of failure. Two schemes based on the application of calculus of variations for selecting control signals are proposed: the first obtains the control force as the solution of a two-point nonlinear boundary value problem, and, the second explores the application of the Volterra series in characterizing the controls. The relative merits of these schemes, vis-à-vis the method based on ideas from the FORM, are discussed. Illustrative examples, involving archetypal single degree of freedom (dof) nonlinear oscillators, and a multi-degree of freedom nonlinear dynamical system, are presented. The credentials of the proposed procedures are established by comparing the solutions with pertinent results from direct Monte Carlo simulations.

  2. THE 6-MINUTE WALK TEST AND OTHER CLINICAL ENDPOINTS IN DUCHENNE MUSCULAR DYSTROPHY: RELIABILITY, CONCURRENT VALIDITY, AND MINIMAL CLINICALLY IMPORTANT DIFFERENCES FROM A MULTICENTER STUDY

    PubMed Central

    McDonald, Craig M; Henricson, Erik K; Abresch, R Ted; Florence, Julaine; Eagle, Michelle; Gappmaier, Eduard; Glanzman, Allan M; Spiegel, Robert; Barth, Jay; Elfring, Gary; Reha, Allen; Peltz, Stuart W

    2013-01-01

    Introduction: An international clinical trial enrolled 174 ambulatory males ≥5 years old with nonsense mutation Duchenne muscular dystrophy (nmDMD). Pretreatment data provide insight into reliability, concurrent validity, and minimal clinically important differences (MCIDs) of the 6-minute walk test (6MWT) and other endpoints. Methods: Screening and baseline evaluations included the 6-minute walk distance (6MWD), timed function tests (TFTs), quantitative strength by myometry, the PedsQL, heart rate–determined energy expenditure index, and other exploratory endpoints. Results: The 6MWT proved feasible and reliable in a multicenter context. Concurrent validity with other endpoints was excellent. The MCID for 6MWD was 28.5 and 31.7 meters based on 2 statistical distribution methods. Conclusions: The ratio of MCID to baseline mean is lower for 6MWD than for other endpoints. The 6MWD is an optimal primary endpoint for Duchenne muscular dystrophy (DMD) clinical trials that are focused therapeutically on preservation of ambulation and slowing of disease progression. Muscle Nerve 48: 357–368, 2013 PMID:23674289

  3. JRC GMO-Matrix: a web application to support Genetically Modified Organisms detection strategies.

    PubMed

    Angers-Loustau, Alexandre; Petrillo, Mauro; Bonfini, Laura; Gatto, Francesco; Rosa, Sabrina; Patak, Alexandre; Kreysa, Joachim

    2014-12-30

    The polymerase chain reaction (PCR) is the current state of the art technique for DNA-based detection of Genetically Modified Organisms (GMOs). A typical control strategy starts by analyzing a sample for the presence of target sequences (GM-elements) known to be present in many GMOs. Positive findings from this "screening" are then confirmed with GM (event) specific test methods. A reliable knowledge of which GMOs are detected by combinations of GM-detection methods is thus crucial to minimize the verification efforts. In this article, we describe a novel platform that links the information of two unique databases built and maintained by the European Union Reference Laboratory for Genetically Modified Food and Feed (EU-RL GMFF) at the Joint Research Centre (JRC) of the European Commission, one containing the sequence information of known GM-events and the other validated PCR-based detection and identification methods. The new platform compiles in silico determinations of the detection of a wide range of GMOs by the available detection methods using existing scripts that simulate PCR amplification and, when present, probe binding. The correctness of the information has been verified by comparing the in silico conclusions to experimental results for a subset of forty-nine GM events and six methods. The JRC GMO-Matrix is unique for its reliance on DNA sequence data and its flexibility in integrating novel GMOs and new detection methods. Users can mine the database using a set of web interfaces that thus provide a valuable support to GMO control laboratories in planning and evaluating their GMO screening strategies. The platform is accessible at http://gmo-crl.jrc.ec.europa.eu/jrcgmomatrix/ .

  4. Validation of a Commercial Insulated Isothermal PCR-based POCKIT Test for Rapid and Easy Detection of White Spot Syndrome Virus Infection in Litopenaeus vannamei

    PubMed Central

    Tsai, Yun-Long; Wang, Han-Ching; Lo, Chu-Fang; Tang-Nelson, Kathy; Lightner, Donald; Ou, Bor-Rung; Hour, Ai-Ling; Tsai, Chuan-Fu; Yen, Cheng-Chi; Chang, Hsiao-Fen Grace; Teng, Ping-Hua; Lee, Pei-Yu

    2014-01-01

    Timely pond-side detection of white spot syndrome virus (WSSV) plays a critical role in the implementation of bio-security measures to help minimize economic losses caused by white spot syndrome disease, an important threat to shrimp aquaculture industry worldwide. A portable device, namely POCKIT™, became available recently to complete fluorescent probe-based insulated isothermal PCR (iiPCR), and automatic data detection and interpretation within one hour. Taking advantage of this platform, the IQ Plus™ WSSV Kit with POCKIT system was established to allow simple and easy WSSV detection for on-site users. The assay was first evaluated for its analytical sensitivity and specificity performance. The 95% limit of detection (LOD) of the assay was 17 copies of WSSV genomic DNA per reaction (95% confidence interval [CI], 13 to 24 copies per reaction). The established assay has detection sensitivity similar to that of OIE-registered IQ2000™ WSSV Detection and Protection System with serial dilutions of WSSV-positive Litopenaeus vannamei DNA. No cross-reaction signals were generated from infectious hypodermal and haematopoietic necrosis virus (IHHNV), monodon baculovirus (MBV), and hepatopancreatic parvovirus (HPV) positive samples. Accuracy analysis using700 L. vannamei of known WSSV infection status shows that the established assayhassensitivity93.5% (95% CI: 90.61–95.56%) and specificity 97% (95% CI: 94.31–98.50%). Furthermore, no discrepancy was found between the two assays when 100 random L. vannamei samples were tested in parallel. Finally, excellent correlation was observed among test results of three batches of reagents with 64 samples analyzed in three different laboratories. Working in a portable device, IQ Plus™ WSSV Kit with POCKIT system allows reliable, sensitive and specific on-site detection of WSSV in L. vannamei. PMID:24625894

  5. Establishing Immediate Reliability of Sonographic Measurements of the Transversus Abdominis in Asymptomatic Adults Performing Upright Loaded Functional Tasks in a Clinical Context Without Delayed Recorded Measurement.

    PubMed

    McPherson, Sue; Watson, Todd; Pate, Lindsey

    2016-08-01

    This study examined the reliability of sonographic measurements of the transversus abdominis of adults without low back pain during upright loaded functional tasks in real time, without relying on delayed recorded images. A single-group repeated-measures reliability study was conducted on 12 healthy participants without low back pain. Six of these adults reported a prior history of abdominal drawing-in maneuver training without sonographic measurement. The participants performed 3 trials of neutral standing, a loaded forward reach, and a loaded box lift under rest and with abdominal drawing-in maneuver instructions; task order was randomized. Transversus abdominis thickness measurements were obtained by an experienced rater using B-mode sonography in real-time via electronic calipers twice on the same static image during all trials by a rater. The rater was masked to group assignment and on-screen measurement output and required to respond to trivia questions between repeated measurements. The participants included 6 male and 6 female adults with a mean age ± SD of 26.3 ± 3.7 years. Intra-rater intraclass correlation coefficients (2,3) were high and precise for the rater's first and second measurements for all tasks and instruction conditions for mean transversus abdominis thickness and percent change in thickness measurements (eg, ranges were 0.968-0.997 for intraclass correlation coefficients, 0.01-0.21 mm for standard errors of the measurement, and 0.01-0.58 mm for minimal detectable changes). Calipers cleared by the rater or a research assistant produced similar findings of excellent reliability and precision. High intra-rater reliability and precision of transversus abdominis thickness measurements were obtained by a physical therapist in real time from asymptomatic adults performing upright loaded functional tasks under rest and with abdominal drawing-in maneuver instructions.

  6. Cross-cultural adaptation and validation of the Patient-Rated Tennis Elbow Evaluation Questionnaire on lateral elbow tendinopathy for French-speaking patients.

    PubMed

    Kaux, Jean-François; Delvaux, François; Schaus, Jean; Demoulin, Christophe; Locquet, Médéa; Buckinx, Fanny; Beaudart, Charlotte; Dardenne, Nadia; Van Beveren, Julien; Croisier, Jean-Louis; Forthomme, Bénédicte; Bruyère, Olivier

    Translation and validation of algo-functional questionnaire. The lateral elbow tendinopathy is a common injury in tennis players and physical workers. The Patient-Rated Tennis Elbow Evaluation (PRTEE) Questionnaire was specifically designed to measure pain and functional limitations in patients with lateral epicondylitis (tennis elbow). First developed in English, this questionnaire has since been translated into several languages. The aims of the study were to translate and cross-culturally adapt the PRTEE questionnaire into French and to evaluate the reliability and validity of this translated version of the questionnaire (PRTEE-F). The PRTEE was translated and cross-culturally adapted into French according to international guidelines. To assess the reliability and validity of the PRTEE-F, 115 participants were asked twice to fill in the PRTEE-F, and once the Disabilities of Arm, Shoulder and Hand Questionnaire (DASH) and the Short Form Health Survey (SF-36). Internal consistency (using Cronbach's alpha), test-retest reliability (using intraclass correlation coefficient (ICC), standard error of measurement and minimal detectable change), and convergent and divergent validity (using the Spearman's correlation coefficients respectively with the DASH and with some subscales of the SF-36) were assessed. The PRTEE was translated into French without any problems. PRTEE-F showed a good test-retest reliability for the overall score (ICC 0.86) and for each item (ICC 0.8-0.96) and a high internal consistency (Cronbach's alpha = 0.98). The correlation analyses revealed high correlation coefficients between PRTEE-F and DASH (convergent validity) and, as expected, a low or moderate correlation with the divergent subscales of the SF-36 (discriminant validity). There was no floor or ceiling effect. The PRTEE questionnaire was successfully cross-culturally adapted into French. The PRTEE-F is reliable and valid for evaluating French-speaking patients with lateral elbow tendinopathy. Copyright © 2016 Hanley & Belfus. Published by Elsevier Inc. All rights reserved.

  7. Cross cultural adaptation of the Achilles tendon Total Rupture Score with reliability, validity and responsiveness evaluation.

    PubMed

    Carmont, Michael R; Silbernagel, Karin Grävare; Nilsson-Helander, Katarina; Mei-Dan, Omer; Karlsson, Jon; Maffulli, Nicola

    2013-06-01

    The Achilles tendon Total Rupture Score (ATRS) was developed because of the need for a reliable, valid and sensitive instrument to evaluate symptoms and their effects on physical activity in patients following either conservative or surgical management of an Achilles tendon rupture. Prior to using the score in larger randomized trial in an English-speaking population, we decided to perform reliability, validity and responsiveness evaluations of the English version of the ATRS. Even though the score was published in English, the actual English version has not be validated and compared to the results of the Swedish version. From 2009 to 2010, all patients who received treatment for Achilles tendon rupture were followed up using the English version of the ATRS. Patients were asked to complete the score at 3, 6 and 12 months following treatment for Achilles tendon rupture. The ATRS was completed on arrival in the outpatient clinic and again following consultation. The outcomes of 49 (13 female and 36 male) patients were assessed. The mean (SD) age was 49 (12) years, and 27 patients had treatment for a left-sided rupture, 22 the right. All patients received treatment for ruptured Achilles tendons: 38 acute percutaneous repair, 1 open repair, 5 an Achilles tendon reconstruction using a Peroneus Brevis tendon transfer for delayed presentation, 1 gracilis augmented repair for re-rupture and 4 non-operative treatment for mid-portion rupture. The English version of ATRS was shown to have overall excellent reliability (ICC = 0.986). There was no significant difference between the results with the English version and the Swedish version when compared at the 6-month- or 12-month (n.s.) follow-up appointments. The effect size was 0.93. The minimal detectable change was 6.75 points. The ATRS was culturally adapted to English and shown to be a reliable, valid and responsive method of testing functional outcome following an Achilles tendon rupture.

  8. Detecting long-term growth trends using tree rings: a critical evaluation of methods.

    PubMed

    Peters, Richard L; Groenendijk, Peter; Vlam, Mart; Zuidema, Pieter A

    2015-05-01

    Tree-ring analysis is often used to assess long-term trends in tree growth. A variety of growth-trend detection methods (GDMs) exist to disentangle age/size trends in growth from long-term growth changes. However, these detrending methods strongly differ in approach, with possible implications for their output. Here, we critically evaluate the consistency, sensitivity, reliability and accuracy of four most widely used GDMs: conservative detrending (CD) applies mathematical functions to correct for decreasing ring widths with age; basal area correction (BAC) transforms diameter into basal area growth; regional curve standardization (RCS) detrends individual tree-ring series using average age/size trends; and size class isolation (SCI) calculates growth trends within separate size classes. First, we evaluated whether these GDMs produce consistent results applied to an empirical tree-ring data set of Melia azedarach, a tropical tree species from Thailand. Three GDMs yielded similar results - a growth decline over time - but the widely used CD method did not detect any change. Second, we assessed the sensitivity (probability of correct growth-trend detection), reliability (100% minus probability of detecting false trends) and accuracy (whether the strength of imposed trends is correctly detected) of these GDMs, by applying them to simulated growth trajectories with different imposed trends: no trend, strong trends (-6% and +6% change per decade) and weak trends (-2%, +2%). All methods except CD, showed high sensitivity, reliability and accuracy to detect strong imposed trends. However, these were considerably lower in the weak or no-trend scenarios. BAC showed good sensitivity and accuracy, but low reliability, indicating uncertainty of trend detection using this method. Our study reveals that the choice of GDM influences results of growth-trend studies. We recommend applying multiple methods when analysing trends and encourage performing sensitivity and reliability analysis. Finally, we recommend SCI and RCS, as these methods showed highest reliability to detect long-term growth trends. © 2014 John Wiley & Sons Ltd.

  9. Rapid colorimetric detection of Zika virus from serum and urine specimens by reverse transcription loop-mediated isothermal amplification (RT-LAMP)

    PubMed Central

    Biggerstaff, Brad J.; Tanner, Nathan A.; Lauterbach, Molly; Lanciotti, Robert S.

    2017-01-01

    Zika virus (ZIKV) has emerged as a major global public health concern in the last two years due to its link as a causative agent of human birth defects. Its rapid expansion into the Western Hemisphere as well as the ability to be transmitted from mother to fetus, through sexual transmission and possibly through blood transfusions has increased the need for a rapid and expansive public health response to this unprecedented epidemic. A non-invasive and rapid ZIKV diagnostic screening assay that can be performed in a clinical setting throughout pregnancy is vital for prenatal care of women living in areas of the world where exposure to the virus is possible. To meet this need we have developed a sensitive and specific reverse transcriptase loop-mediated isothermal amplification (RT-LAMP) assay to detect ZIKV RNA in urine and serum with a simple visual detection. RT-LAMP results were shown to have a limit of detection 10-fold higher than qRT-PCR. As little as 1.2 RNA copies/μl was detected by RT-LAMP from a panel of 178 diagnostic specimens. The assay was shown to be highly specific for ZIKV RNA when tested with diagnostic specimens positive for dengue virus (DENV) and chikungunya virus (CHIKV). The assay described here illustrates the potential for a fast, reliable, sensitive and specific assay for the detection of ZIKV from urine or serum that can be performed in a clinical or field setting with minimal equipment and technological expertise. PMID:28945787

  10. Rapid immunohistochemical detection of tumor cells in gastric carcinoma.

    PubMed

    Mönig, Stefan P; Luebke, Thomas; Soheili, Afsoon; Landsberg, Stephanie; Dienes, H P; Hölscher, Arnulf H; Baldus, Stephan E

    2006-11-01

    The detection of single tumor cells or tumor cell clusters represents an important issue in intraoperative frozen section analysis. For example, surgical margins may be evaluated in order to minimize the number of additional operations. Furthermore, intraoperative diagnosis of lymph node micrometastasis (LNM) may help to define the area of appropriate lymph node dissection. In addition to haematoxylin and eosin (H&E)-stained sections, immunohistochemical detection of single tumor cells or cell clusters may be helpful in this context. The aim of this study was to evaluate the clinical significance, reliability and sensitivity of intraoperative rapid immunostaining of frozen sections. Therefore, we compared the results of rapid immunohistochemical staining of frozen sections and paraffin sections applying the EnVision and Histofine(R) detection systems. In a prospective immunohistochemical study, paraffin and frozen sections of 20 gastric cancer specimens were analyzed. Paraffin as well as frozen sections were stained immunohistochemically applying the EnVision and Histofine detection systems. As primary antibodies, AE1/AE3 (anti-cytokeratin), EMA (anti-MUC1) and B lymphocyte marker anti-CD20 were applied. The rapid immunostaining procedure was able to be completed within 10-13 min. Rapid immunohistochemical staining of frozen and paraffin sections of the same tumors resulted in comparable immunoreactivity. The rapid EnVision and Histofine procedures allowed immunostaining of frozen sections in less than 13 min. These methods can represent useful additional tools in routine surgical pathology and research, enabling a more accurate frozen section diagnosis compared to staining with H&E alone. Intraoperative rapid immunostaining can be a simple and useful technique to detect LNM.

  11. Rapid colorimetric detection of Zika virus from serum and urine specimens by reverse transcription loop-mediated isothermal amplification (RT-LAMP).

    PubMed

    Calvert, Amanda E; Biggerstaff, Brad J; Tanner, Nathan A; Lauterbach, Molly; Lanciotti, Robert S

    2017-01-01

    Zika virus (ZIKV) has emerged as a major global public health concern in the last two years due to its link as a causative agent of human birth defects. Its rapid expansion into the Western Hemisphere as well as the ability to be transmitted from mother to fetus, through sexual transmission and possibly through blood transfusions has increased the need for a rapid and expansive public health response to this unprecedented epidemic. A non-invasive and rapid ZIKV diagnostic screening assay that can be performed in a clinical setting throughout pregnancy is vital for prenatal care of women living in areas of the world where exposure to the virus is possible. To meet this need we have developed a sensitive and specific reverse transcriptase loop-mediated isothermal amplification (RT-LAMP) assay to detect ZIKV RNA in urine and serum with a simple visual detection. RT-LAMP results were shown to have a limit of detection 10-fold higher than qRT-PCR. As little as 1.2 RNA copies/μl was detected by RT-LAMP from a panel of 178 diagnostic specimens. The assay was shown to be highly specific for ZIKV RNA when tested with diagnostic specimens positive for dengue virus (DENV) and chikungunya virus (CHIKV). The assay described here illustrates the potential for a fast, reliable, sensitive and specific assay for the detection of ZIKV from urine or serum that can be performed in a clinical or field setting with minimal equipment and technological expertise.

  12. Relating design and environmental variables to reliability

    NASA Astrophysics Data System (ADS)

    Kolarik, William J.; Landers, Thomas L.

    The combination of space application and nuclear power source demands high reliability hardware. The possibilities of failure, either an inability to provide power or a catastrophic accident, must be minimized. Nuclear power experiences on the ground have led to highly sophisticated probabilistic risk assessment procedures, most of which require quantitative information to adequately assess such risks. In the area of hardware risk analysis, reliability information plays a key role. One of the lessons learned from the Three Mile Island experience is that thorough analyses of critical components are essential. Nuclear grade equipment shows some reliability advantages over commercial. However, no statistically significant difference has been found. A recent study pertaining to spacecraft electronics reliability, examined some 2500 malfunctions on more than 300 aircraft. The study classified the equipment failures into seven general categories. Design deficiencies and lack of environmental protection accounted for about half of all failures. Within each class, limited reliability modeling was performed using a Weibull failure model.

  13. Advances in developing rapid, reliable and portable detection systems for alcohol.

    PubMed

    Thungon, Phurpa Dema; Kakoti, Ankana; Ngashangva, Lightson; Goswami, Pranab

    2017-11-15

    Development of portable, reliable, sensitive, simple, and inexpensive detection system for alcohol has been an instinctive demand not only in traditional brewing, pharmaceutical, food and clinical industries but also in rapidly growing alcohol based fuel industries. Highly sensitive, selective, and reliable alcohol detections are currently amenable typically through the sophisticated instrument based analyses confined mostly to the state-of-art analytical laboratory facilities. With the growing demand of rapid and reliable alcohol detection systems, an all-round attempt has been made over the past decade encompassing various disciplines from basic and engineering sciences. Of late, the research for developing small-scale portable alcohol detection system has been accelerated with the advent of emerging miniaturization techniques, advanced materials and sensing platforms such as lab-on-chip, lab-on-CD, lab-on-paper etc. With these new inter-disciplinary approaches along with the support from the parallel knowledge growth on rapid detection systems being pursued for various targets, the progress on translating the proof-of-concepts to commercially viable and environment friendly portable alcohol detection systems is gaining pace. Here, we summarize the progress made over the years on the alcohol detection systems, with a focus on recent advancement towards developing portable, simple and efficient alcohol sensors. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Assessment of NDE reliability data

    NASA Technical Reports Server (NTRS)

    Yee, B. G. W.; Couchman, J. C.; Chang, F. H.; Packman, D. F.

    1975-01-01

    Twenty sets of relevant nondestructive test (NDT) reliability data were identified, collected, compiled, and categorized. A criterion for the selection of data for statistical analysis considerations was formulated, and a model to grade the quality and validity of the data sets was developed. Data input formats, which record the pertinent parameters of the defect/specimen and inspection procedures, were formulated for each NDE method. A comprehensive computer program was written and debugged to calculate the probability of flaw detection at several confidence limits by the binomial distribution. This program also selects the desired data sets for pooling and tests the statistical pooling criteria before calculating the composite detection reliability. An example of the calculated reliability of crack detection in bolt holes by an automatic eddy current method is presented.

  15. Reliable gene expression analysis by reverse transcription-quantitative PCR: reporting and minimizing the uncertainty in data accuracy.

    PubMed

    Remans, Tony; Keunen, Els; Bex, Geert Jan; Smeets, Karen; Vangronsveld, Jaco; Cuypers, Ann

    2014-10-01

    Reverse transcription-quantitative PCR (RT-qPCR) has been widely adopted to measure differences in mRNA levels; however, biological and technical variation strongly affects the accuracy of the reported differences. RT-qPCR specialists have warned that, unless researchers minimize this variability, they may report inaccurate differences and draw incorrect biological conclusions. The Minimum Information for Publication of Quantitative Real-Time PCR Experiments (MIQE) guidelines describe procedures for conducting and reporting RT-qPCR experiments. The MIQE guidelines enable others to judge the reliability of reported results; however, a recent literature survey found low adherence to these guidelines. Additionally, even experiments that use appropriate procedures remain subject to individual variation that statistical methods cannot correct. For example, since ideal reference genes do not exist, the widely used method of normalizing RT-qPCR data to reference genes generates background noise that affects the accuracy of measured changes in mRNA levels. However, current RT-qPCR data reporting styles ignore this source of variation. In this commentary, we direct researchers to appropriate procedures, outline a method to present the remaining uncertainty in data accuracy, and propose an intuitive way to select reference genes to minimize uncertainty. Reporting the uncertainty in data accuracy also serves for quality assessment, enabling researchers and peer reviewers to confidently evaluate the reliability of gene expression data. © 2014 American Society of Plant Biologists. All rights reserved.

  16. Minimally Invasive Surgery Survey: A Survey of Surgical Team Members' Perceptions for Successful Minimally Invasive Surgery.

    PubMed

    Yurteri-Kaplan, Ladin A; Andriani, Leslie; Kumar, Anagha; Saunders, Pamela A; Mete, Mihriye M; Sokol, Andrew I

    To develop a valid and reliable survey to measure surgical team members' perceptions regarding their institution's requirements for successful minimally invasive surgery (MIS). Questionnaire development and validation study (Canadian Task Force classification II-2). Three hospital types: rural, urban/academic, and community/academic. Minimally invasive staff (team members). Development and validation of a minimally invasive surgery survey (MISS). Using the Safety Attitudes questionnaire as a guide, we developed questions assessing study participants' attitudes regarding the requirements for successful MIS. The questions were closed-ended and responses based on a 5-point Likert scale. The large pool of questions was then given to 4 focus groups made up of 3 to 6 individuals. Each focus group consisted of individuals from a specific profession (e.g., surgeons, anesthesiologists, nurses, and surgical technicians). Questions were revised based on focus group recommendations, resulting in a final 52-question set. The question set was then distributed to MIS team members. Individuals were included if they had participated in >10 MIS cases and worked in the MIS setting in the past 3 months. Participants in the trial population were asked to repeat the questionnaire 4 weeks later to evaluate internal consistency. Participants' demographics, including age, gender, specialty, profession, and years of experience, were captured in the questionnaire. Factor analysis with varimax rotation was performed to determine domains (questions evaluating similar themes). For internal consistency and reliability, domains were tested using interitem correlations and Cronbach's α. Cronbach's α > .6 was considered internally consistent. Kendall's correlation coefficient τ closer to 1 and with p < .05 was considered significant for the test-retest reliability. Two hundred fifty participants answered the initial question set. Of those, 53 were eliminated because they did not meet inclusion criteria or failed to answer all questions, leaving 197 participants. Most participants were women (68% vs 32%), and 42% were between the ages 30 and 39 years. Factor analysis identified 6 domains: collaboration, error reporting, job proficiency/efficiency, problem-solving, job satisfaction, and situational awareness. Interitem correlations testing for redundancy for each domain ranged from .2 to .7, suggesting similar themed questions while avoiding redundancy. Cronbach's α, testing internal consistency, was .87. Sixty-two participants from the original cohort repeated the question set at 4 weeks. Forty-three were analyzed for test-retest reliability after excluding those who did not meet inclusion criteria. The final questions showed high test-retest reliability (τ = .3-.7, p < .05). The final questionnaire was made up of 29 questions from the original 52 question set. The MISS is a reliable and valid tool that can be used to measure how surgical team members conceptualize the requirements for successful MIS. The MISS revealed that participants identified 6 important domains of a successful workenvironment: collaboration, error reporting, job proficiency/efficiency, problem-solving, job satisfaction, and situational awareness. The questionnaire can be used to understand and align various surgical team members' goals and expectations and may help improve quality of care in the MIS setting. Copyright © 2017 American Association of Gynecologic Laparoscopists. Published by Elsevier Inc. All rights reserved.

  17. Reliability and validity of cervical position measurements in individuals with and without chronic neck pain.

    PubMed

    Dunleavy, Kim; Neil, Joseph; Tallon, Allison; Adamo, Diane E

    2015-09-01

    The cervical range of motion device (CROM) has been shown to provide reliable forward head position (FHP) measurement when the upper cervical angle (UCA) is controlled. However, measurement without UCA standardization is reflective of habitual patterns. Criterion validity has not been reported. The purposes of this study were to establish: (1) criterion validity of CROM FHP and UCA compared to Optotrak data, (2) relative reliability and minimal detectable change (MDC95) in patients with and without cervical pain, and (3) to compare UCA and FHP in patients with and without pain in habitual postures. (1) Within-subjects single session concurrent criterion validity design. Simultaneous CROM and OP measurement was conducted in habitual sitting posture in 16 healthy young adults. (2) Reliability and MDC95 of UCA and FHP were calculated from three trials. (3) Values for adults over 35 years with cervical pain and age-matched healthy controls were compared. (1) Forward head position distances were moderately correlated and UCA angles were highly correlated. The mean (standard deviation) differences can be expected to vary between 1·48 cm (1·74) for FHP and -1·7 (2·46)° for UCA. (2) Reliability for CROM FHP measurements were good to excellent (no pain) and moderate (pain). Cervical range of motion FHP MDC95 was moderately low (no pain), and moderate (pain). Reliability for CROM UCA measurements was excellent and MDC95 low for both groups. There was no difference in FHP distances between the pain and no pain groups, UCA was significantly more extended in the pain group (P<0·05). Cervical range of motion FHP measurements were only moderately correlated with Optotrak data, and limits of agreement (LOA) and MDC95 were relatively large. There was also no difference in CROM FHP distance between older symptomatic and asymptomatic individuals. Cervical range of motion FHP measurement is therefore not recommended as a clinical outcome measure. Cervical range of motion UCA measurements showed good criterion validity, excellent test-retest reliability, and achievable MDC95 in asymptomatic and symptomatic participants. Differences of more than 6° are required to exceed error. Cervical range of motion UCA shows promise as a useful reliable and valid measurement, particularly as patients with cervical pain exhibited significantly more extended angles.

  18. Reliability and validity of cervical position measurements in individuals with and without chronic neck pain

    PubMed Central

    Neil, Joseph; Tallon, Allison; Adamo, Diane E.

    2015-01-01

    Objectives The cervical range of motion device (CROM) has been shown to provide reliable forward head position (FHP) measurement when the upper cervical angle (UCA) is controlled. However, measurement without UCA standardization is reflective of habitual patterns. Criterion validity has not been reported. The purposes of this study were to establish: (1) criterion validity of CROM FHP and UCA compared to Optotrak data, (2) relative reliability and minimal detectable change (MDC95) in patients with and without cervical pain, and (3) to compare UCA and FHP in patients with and without pain in habitual postures. Methods (1) Within-subjects single session concurrent criterion validity design. Simultaneous CROM and OP measurement was conducted in habitual sitting posture in 16 healthy young adults. (2) Reliability and MDC95 of UCA and FHP were calculated from three trials. (3) Values for adults over 35 years with cervical pain and age-matched healthy controls were compared. Results (1) Forward head position distances were moderately correlated and UCA angles were highly correlated. The mean (standard deviation) differences can be expected to vary between 1·48 cm (1·74) for FHP and −1·7 (2·46)° for UCA. (2) Reliability for CROM FHP measurements were good to excellent (no pain) and moderate (pain). Cervical range of motion FHP MDC95 was moderately low (no pain), and moderate (pain). Reliability for CROM UCA measurements was excellent and MDC95 low for both groups. There was no difference in FHP distances between the pain and no pain groups, UCA was significantly more extended in the pain group (P<0·05). Discussion Cervical range of motion FHP measurements were only moderately correlated with Optotrak data, and limits of agreement (LOA) and MDC95 were relatively large. There was also no difference in CROM FHP distance between older symptomatic and asymptomatic individuals. Cervical range of motion FHP measurement is therefore not recommended as a clinical outcome measure. Cervical range of motion UCA measurements showed good criterion validity, excellent test–retest reliability, and achievable MDC95 in asymptomatic and symptomatic participants. Differences of more than 6° are required to exceed error. Cervical range of motion UCA shows promise as a useful reliable and valid measurement, particularly as patients with cervical pain exhibited significantly more extended angles. PMID:26917936

  19. Cardiopulmonary exercise testing early after stroke using feedback-controlled robotics-assisted treadmill exercise: test-retest reliability and repeatability.

    PubMed

    Stoller, Oliver; de Bruin, Eling D; Schindelholz, Matthias; Schuster-Amft, Corina; de Bie, Rob A; Hunt, Kenneth J

    2014-10-11

    Exercise capacity is seriously reduced after stroke. While cardiopulmonary assessment and intervention strategies have been validated for the mildly and moderately impaired populations post-stroke, there is a lack of effective concepts for stroke survivors suffering from severe motor limitations. This study investigated the test-retest reliability and repeatability of cardiopulmonary exercise testing (CPET) using feedback-controlled robotics-assisted treadmill exercise (FC-RATE) in severely motor impaired individuals early after stroke. 20 subjects (age 44-84 years, <6 month post-stroke) with severe motor limitations (Functional Ambulatory Classification 0-2) were selected for consecutive constant load testing (CLT) and incremental exercise testing (IET) within a powered exoskeleton, synchronised with a treadmill and a body weight support system. A manual human-in-the-loop feedback system was used to guide individual work rate levels. Outcome variables focussed on standard cardiopulmonary performance parameters. Relative and absolute test-retest reliability were assessed by intraclass correlation coefficients (ICC), standard error of the measurement (SEM), and minimal detectable change (MDC). Mean difference, limits of agreement, and coefficient of variation (CoV) were estimated to assess repeatability. Peak performance parameters during IET yielded good to excellent relative reliability: absolute peak oxygen uptake (ICC =0.82), relative peak oxygen uptake (ICC =0.72), peak work rate (ICC =0.91), peak heart rate (ICC =0.80), absolute gas exchange threshold (ICC =0.91), relative gas exchange threshold (ICC =0.88), oxygen cost of work (ICC =0.87), oxygen pulse at peak oxygen uptake (ICC =0.92), ventilation rate versus carbon dioxide output slope (ICC =0.78). For these variables, SEM was 4-13%, MDC 12-36%, and CoV 0.10-0.36. CLT revealed high mean differences and insufficient test-retest reliability for all variables studied. This study presents first evidence on reliability and repeatability for CPET in severely motor impaired individuals early after stroke using a feedback-controlled robotics-assisted treadmill. The results demonstrate good to excellent test-retest reliability and appropriate repeatability for the most important peak cardiopulmonary performance parameters. These findings have important implications for the design and implementation of cardiovascular exercise interventions in severely impaired populations. Future research needs to develop advanced control strategies to enable the true limit of functional exercise capacity to be reached and to further assess test-retest reliability and repeatability in larger samples.

  20. Reliability and Validity of Dual-Task Mobility Assessments in People with Chronic Stroke

    PubMed Central

    Yang, Lei; He, Chengqi; Pang, Marco Yiu Chung

    2016-01-01

    Background The ability to perform a cognitive task while walking simultaneously (dual-tasking) is important in real life. However, the psychometric properties of dual-task walking tests have not been well established in stroke. Objective To assess the test-retest reliability, concurrent and known-groups validity of various dual-task walking tests in people with chronic stroke. Design Observational measurement study with a test-retest design. Methods Eighty-eight individuals with chronic stroke participated. The testing protocol involved four walking tasks (walking forward at self-selected and maximal speed, walking backward at self-selected speed, and crossing over obstacles) performed simultaneously with each of the three attention-demanding tasks (verbal fluency, serial 3 subtractions or carrying a cup of water). For each dual-task condition, the time taken to complete the walking task, the correct response rate (CRR) of the cognitive task, and the dual-task effect (DTE) for the walking time and CRR were calculated. Forty-six of the participants were tested twice within 3–4 days to establish test-retest reliability. Results The walking time in various dual-task assessments demonstrated good to excellent reliability [Intraclass correlation coefficient (ICC2,1) = 0.70–0.93; relative minimal detectable change at 95% confidence level (MDC95%) = 29%-45%]. The reliability of the CRR (ICC2,1 = 0.58–0.81) and the DTE in walking time (ICC2,1 = 0.11–0.80) was more varied. The reliability of the DTE in CRR (ICC2,1 = -0.31–0.40) was poor to fair. The walking time and CRR obtained in various dual-task walking tests were moderately to strongly correlated with those of the dual-task Timed-up-and-Go test, thus demonstrating good concurrent validity. None of the tests could discriminate fallers (those who had sustained at least one fall in the past year) from non-fallers. Limitation The results are generalizable to community-dwelling individuals with chronic stroke only. Conclusions The walking time derived from the various dual-task assessments generally demonstrated good to excellent reliability, making them potentially useful in clinical practice and future research endeavors. However, the usefulness of these measurements in predicting falls needs to be further explored. Relatively low reliability was shown in the cognitive outcomes and DTE, which may not be preferred measurements for assessing dual-task performance. PMID:26808662

  1. Excitation-emission matrix fluorescence spectroscopy in conjunction with multiway analysis for PAH detection in complex matrices.

    PubMed

    Nahorniak, Michelle L; Booksh, Karl S

    2006-12-01

    A field portable, single exposure excitation-emission matrix (EEM) fluorometer has been constructed and used in conjunction with parallel factor analysis (PARAFAC) to determine the sub part per billion (ppb) concentrations of several aqueous polycyclic aromatic hydrocarbons (PAHs), such as benzo(k)fluoranthene and benzo(a)pyrene, in various matrices including aqueous motor oil extract and asphalt leachate. Multiway methods like PARAFAC are essential to resolve the analyte signature from the ubiquitous background in environmental samples. With multiway data and PARAFAC analysis it is shown that reliable concentration determinations can be achieved with minimal standards in spite of the large convoluting fluorescence background signal. Thus, rapid fieldable EEM analyses may prove to be a good screening method for tracking pollutants and prioritizing sampling and analysis by more complete but time consuming and labor intensive EPA methods.

  2. Sjogren's syndrome from the perspective of ophthalmology.

    PubMed

    Kuklinski, Eric; Asbell, Penny A

    2017-09-01

    Sjogren's syndrome (SS) is an autoimmune disease affecting the lacrimal glands resulting in dry eye disease (DED). Ophthalmologists may be the first line of detection of Sjogren's syndrome given the frequency of DED in SS and that dry eye is often the presenting symptom. Numerous symptom questionnaires and tests have been developed to help diagnose DED, but as of yet, there is no "gold standard." Minimally invasive objective metrics are needed for a reliable diagnosis of DED. Currently there is no single test to diagnose SS-associated DED. Although there are several approaches to treatment, none are specific for DED in SS, and, generally, several methods need to be tried to find what works best for a specific patient. Treatment for DED continues to be an unmet medical need, especially given that DED in SS is typically on the severe end of the spectrum. Copyright © 2017 Elsevier Inc. All rights reserved.

  3. Improved Temperature Diagnostic for Non-Neutral Plasmas with Single-Electron Resolution

    NASA Astrophysics Data System (ADS)

    Shanman, Sabrina; Evans, Lenny; Fajans, Joel; Hunter, Eric; Nelson, Cheyenne; Sierra, Carlos; Wurtele, Jonathan

    2016-10-01

    Plasma temperature diagnostics in a Penning-Malmberg trap are essential for reliably obtaining cold, non-neutral plasmas. We have developed a setup for detecting the initial electrons that escape from a trapped pure electron plasma as the confining electrode potential is slowly reduced. The setup minimizes external noise by using a silicon photomultiplier to capture light emitted from an MCP-amplified phosphor screen. To take advantage of this enhanced resolution, we have developed a new plasma temperature diagnostic analysis procedure which takes discrete electron arrival times as input. We have run extensive simulations comparing this new discrete algorithm to our existing exponential fitting algorithm. These simulations are used to explore the behavior of these two temperature diagnostic procedures at low N and at high electronic noise. This work was supported by the DOE DE-FG02-06ER54904, and the NSF 1500538-PHY.

  4. Post-analytical Issues in Hemostasis and Thrombosis Testing.

    PubMed

    Favaloro, Emmanuel J; Lippi, Giuseppe

    2017-01-01

    Analytical concerns within hemostasis and thrombosis testing are continuously decreasing. This is essentially attributable to modern instrumentation, improvements in test performance and reliability, as well as the application of appropriate internal quality control and external quality assurance measures. Pre-analytical issues are also being dealt with in some newer instrumentation, which are able to detect hemolysis, icteria and lipemia, and, in some cases, other issues related to sample collection such as tube under-filling. Post-analytical issues are generally related to appropriate reporting and interpretation of test results, and these are the focus of the current overview, which provides a brief description of these events, as well as guidance for their prevention or minimization. In particular, we propose several strategies for improved post-analytical reporting of hemostasis assays and advise that this may provide the final opportunity to prevent serious clinical errors in diagnosis.

  5. Singular spectrum analysis in nonlinear dynamics, with applications to paleoclimatic time series

    NASA Technical Reports Server (NTRS)

    Vautard, R.; Ghil, M.

    1989-01-01

    Two dimensions of a dynamical system given by experimental time series are distinguished. Statistical dimension gives a theoretical upper bound for the minimal number of degrees of freedom required to describe the attractor up to the accuracy of the data, taking into account sampling and noise problems. The dynamical dimension is the intrinsic dimension of the attractor and does not depend on the quality of the data. Singular Spectrum Analysis (SSA) provides estimates of the statistical dimension. SSA also describes the main physical phenomena reflected by the data. It gives adaptive spectral filters associated with the dominant oscillations of the system and clarifies the noise characteristics of the data. SSA is applied to four paleoclimatic records. The principal climatic oscillations and the regime changes in their amplitude are detected. About 10 degrees of freedom are statistically significant in the data. Large noise and insufficient sample length do not allow reliable estimates of the dynamical dimension.

  6. Detecting and describing preventive intervention effects in a universal school-based randomized trial targeting delinquent and violent behavior.

    PubMed

    Stoolmiller, M; Eddy, J M; Reid, J B

    2000-04-01

    This study examined theoretical, methodological, and statistical problems involved in evaluating the outcome of aggression on the playground for a universal preventive intervention for conduct disorder. Moderately aggressive children were hypothesized most likely to benefit. Aggression was measured on the playground using observers blind to the group status of the children. Behavior was micro-coded in real time to minimize potential expectancy biases. The effectiveness of the intervention was strongly related to initial levels of aggressiveness. The most aggressive children improved the most. Models that incorporated corrections for low reliability (the ratio of variance due to true time-stable individual differences to total variance) and censoring (a floor effect in the rate data due to short periods of observation) obtained effect sizes 5 times larger than models without such corrections with respect to children who were initially 2 SDs above the mean on aggressiveness.

  7. A comparison of plants and animals in their responses to risk of consumption.

    PubMed

    Karban, Richard; Orrock, John L; Preisser, Evan L; Sih, Andrew

    2016-08-01

    Both plants and animals reduce their risk of being eaten by detecting and responding to herbivore and predator cues. Plants tend to be less mobile and rely on more local information perceived with widely dispersed and redundant tissues. As such, plants can more easily multi-task. Plants are more tolerant of damage and use damage to their own tissues as reliable cues of risk; plants have a higher threshold before responding to the threat of herbivory. Plants also use diverse cues that include fragments of plant tissue and molecular patterns from herbivores, herbivore feeding, or microbial associates of herbivores. Instead of fleeing from attackers, plants reallocate valuable resources to organs at less risk. They minimize unnecessary defenses against unrealized risks and costs of failing to defend against actual risk. Plants can remember and learn, although these abilities are poorly understood. Copyright © 2016 Elsevier Ltd. All rights reserved.

  8. Investigation on the use of artificial neural networks to overcome the effects of environmental and operational changes on guided waves monitoring

    NASA Astrophysics Data System (ADS)

    El Mountassir, M.; Yaacoubi, S.; Dahmene, F.

    2015-07-01

    Intelligent feature extraction and advanced signal processing techniques are necessary for a better interpretation of ultrasonic guided waves signals either in structural health monitoring (SHM) or in nondestructive testing (NDT). Such signals are characterized by at least multi-modal and dispersive components. In addition, in SHM, these signals are closely vulnerable to environmental and operational conditions (EOCs), and can be severely affected. In this paper we investigate the use of Artificial Neural Network (ANN) to overcome these effects and to provide a reliable damage detection method with a minimal of false indications. An experimental case of study (full scale pipe) is presented. Damages sizes have been increased and their shapes modified in different steps. Various parameters such as the number of inputs and the number of hidden neurons were studied to find the optimal configuration of the neural network.

  9. Randomized controlled trials in dentistry: common pitfalls and how to avoid them.

    PubMed

    Fleming, Padhraig S; Lynch, Christopher D; Pandis, Nikolaos

    2014-08-01

    Clinical trials are used to appraise the effectiveness of clinical interventions throughout medicine and dentistry. Randomized controlled trials (RCTs) are established as the optimal primary design and are published with increasing frequency within the biomedical sciences, including dentistry. This review outlines common pitfalls associated with the conduct of randomized controlled trials in dentistry. Common failings in RCT design leading to various types of bias including selection, performance, detection and attrition bias are discussed in this review. Moreover, methods of minimizing and eliminating bias are presented to ensure that maximal benefit is derived from RCTs within dentistry. Well-designed RCTs have both upstream and downstream uses acting as a template for development and populating systematic reviews to permit more precise estimates of treatment efficacy and effectiveness. However, there is increasing awareness of waste in clinical research, whereby resource-intensive studies fail to provide a commensurate level of scientific evidence. Waste may stem either from inappropriate design or from inadequate reporting of RCTs; the importance of robust conduct of RCTs within dentistry is clear. Optimal reporting of randomized controlled trials within dentistry is necessary to ensure that trials are reliable and valid. Common shortcomings leading to important forms or bias are discussed and approaches to minimizing these issues are outlined. Copyright © 2014 Elsevier Ltd. All rights reserved.

  10. Endoscopically assisted tunnel approach for minimally invasive corticotomies: a preliminary report.

    PubMed

    Hernández-Alfaro, Federico; Guijarro-Martínez, Raquel

    2012-05-01

    The dental community has expressed low acceptance of traditional corticotomy techniques for corticotomy-facilitated orthodontics. These procedures are time consuming, entail substantial postoperative morbidity and periodontal risks, and are often perceived as highly invasive. A total of 114 interdental sites were treated in nine consecutive patients. Under local anesthesia, a tunnel approach requiring one to three vertical incisions per arch (depending on the targeted teeth) was used. Piezosurgical corticotomies and elective bone augmentation procedures were performed under endoscopic assistance. Postoperative cone-beam computerized tomography evaluation was used to confirm adequate corticotomy depth. Procedures were completed in a mean time of 26 minutes. Follow-up evaluations revealed no loss of tooth vitality, no changes in periodontal probing depth, good preservation of the papillae, and no gingival recession. No evidence of crestal bone height reduction or apical root resorption was detected. The tunnel approach minimizes soft-tissue debridement and permits effective cortical cuts. The combination of piezosurgery technique with endoscopic assistance provides a quick, reliable means to design and perform these corticotomies while maximizing root integrity preservation. Moreover, the sites needing bone augmentation are selected under direct vision. Compared to traditional corticotomies, this procedure has manifest advantages in surgical time, technical complexity, patient morbidity, and periodontium preservation.

  11. High reliability - low noise radionuclide signature identification algorithms for border security applications

    NASA Astrophysics Data System (ADS)

    Lee, Sangkyu

    Illicit trafficking and smuggling of radioactive materials and special nuclear materials (SNM) are considered as one of the most important recent global nuclear threats. Monitoring the transport and safety of radioisotopes and SNM are challenging due to their weak signals and easy shielding. Great efforts worldwide are focused at developing and improving the detection technologies and algorithms, for accurate and reliable detection of radioisotopes of interest in thus better securing the borders against nuclear threats. In general, radiation portal monitors enable detection of gamma and neutron emitting radioisotopes. Passive or active interrogation techniques, present and/or under the development, are all aimed at increasing accuracy, reliability, and in shortening the time of interrogation as well as the cost of the equipment. Equally important efforts are aimed at advancing algorithms to process the imaging data in an efficient manner providing reliable "readings" of the interiors of the examined volumes of various sizes, ranging from cargos to suitcases. The main objective of this thesis is to develop two synergistic algorithms with the goal to provide highly reliable - low noise identification of radioisotope signatures. These algorithms combine analysis of passive radioactive detection technique with active interrogation imaging techniques such as gamma radiography or muon tomography. One algorithm consists of gamma spectroscopy and cosmic muon tomography, and the other algorithm is based on gamma spectroscopy and gamma radiography. The purpose of fusing two detection methodologies per algorithm is to find both heavy-Z radioisotopes and shielding materials, since radionuclides can be identified with gamma spectroscopy, and shielding materials can be detected using muon tomography or gamma radiography. These combined algorithms are created and analyzed based on numerically generated images of various cargo sizes and materials. In summary, the three detection methodologies are fused into two algorithms with mathematical functions providing: reliable identification of radioisotopes in gamma spectroscopy; noise reduction and precision enhancement in muon tomography; and the atomic number and density estimation in gamma radiography. It is expected that these new algorithms maybe implemented at portal scanning systems with the goal to enhance the accuracy and reliability in detecting nuclear materials inside the cargo containers.

  12. Detection of CMOS bridging faults using minimal stuck-at fault test sets

    NASA Technical Reports Server (NTRS)

    Ijaz, Nabeel; Frenzel, James F.

    1993-01-01

    The performance of minimal stuck-at fault test sets at detecting bridging faults are evaluated. New functional models of circuit primitives are presented which allow accurate representation of bridging faults under switch-level simulation. The effectiveness of the patterns is evaluated using both voltage and current testing.

  13. Exploration of Objective Functions for Optimal Placement of Weather Stations

    NASA Astrophysics Data System (ADS)

    Snyder, A.; Dietterich, T.; Selker, J. S.

    2016-12-01

    Many regions of Earth lack ground-based sensing of weather variables. For example, most countries in Sub-Saharan Africa do not have reliable weather station networks. This absence of sensor data has many consequences ranging from public safety (poor prediction and detection of severe weather events), to agriculture (lack of crop insurance), to science (reduced quality of world-wide weather forecasts, climate change measurement, etc.). The Trans-African Hydro-Meteorological Observatory (TAHMO.org) project seeks to address these problems by deploying and operating a large network of weather stations throughout Sub-Saharan Africa. To design the TAHMO network, we must determine where to locate each weather station. We can formulate this as the following optimization problem: Determine a set of N sites that jointly optimize the value of an objective function. The purpose of this poster is to propose and assess several objective functions. In addition to standard objectives (e.g., minimizing the summed squared error of interpolated values over the entire region), we consider objectives that minimize the maximum error over the region and objectives that optimize the detection of extreme events. An additional issue is that each station measures more than 10 variables—how should we balance the accuracy of our interpolated maps for each variable? Weather sensors inevitably drift out of calibration or fail altogether. How can we incorporate robustness to failed sensors into our network design? Another important requirement is that the network should make it possible to detect failed sensors by comparing their readings with those of other stations. How can this requirement be met? Finally, we provide an initial assessment of the computational cost of optimizing these various objective functions. We invite everyone to join the discussion at our poster by proposing additional objectives, identifying additional issues to consider, and expanding our bibliography of relevant papers. A prize (derived from grapes grown in Oregon) will be awarded for the most insightful contribution to the discussion!

  14. Methods to Improve Reliability of Video Recorded Behavioral Data

    PubMed Central

    Haidet, Kim Kopenhaver; Tate, Judith; Divirgilio-Thomas, Dana; Kolanowski, Ann; Happ, Mary Beth

    2009-01-01

    Behavioral observation is a fundamental component of nursing practice and a primary source of clinical research data. The use of video technology in behavioral research offers important advantages to nurse scientists in assessing complex behaviors and relationships between behaviors. The appeal of using this method should be balanced, however, by an informed approach to reliability issues. In this paper, we focus on factors that influence reliability, such as the use of sensitizing sessions to minimize participant reactivity and the importance of training protocols for video coders. In addition, we discuss data quality, the selection and use of observational tools, calculating reliability coefficients, and coding considerations for special populations based on our collective experiences across three different populations and settings. PMID:19434651

  15. King-Devick Test reference values and associations with balance measures in high school American football players.

    PubMed

    Alsalaheen, B; Haines, J; Yorke, A; Diebold, J

    2016-02-01

    The King-Devick test appears to be a promising tool in screening for concussions. However, limited evidence exists on the baseline associations between the K-D test and age and baseline screening tools used after concussion. Additionally, there are no published reference values for the K-D test in high school football players. The K-D test, the Balance Error Scoring System, and the Limits of Stability (LOS) test were administered to 157 high school football players. Additionally, a subsample of 62 participants completed the test twice to examine the reliability of K-D test. There was no relationship between the K-D test and the BESS, or the reaction time and directional control of LOS test. Students aged between 16 and 18 years demonstrated faster K-D test performance compared to students between 13 and 15 years of age. However, there was no association between K-D test and history of concussion. The reliability of the K-D test was (ICC2,1 = 0.89), and the minimal detectable change was 6.10 s. Normative reference values for high school football players are presented in this study. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  16. Hypermutable DNA chronicles the evolution of human colon cancer

    PubMed Central

    Naxerova, Kamila; Brachtel, Elena; Salk, Jesse J.; Seese, Aaron M.; Power, Karen; Abbasi, Bardia; Snuderl, Matija; Chiang, Sarah; Kasif, Simon; Jain, Rakesh K.

    2014-01-01

    Intratumor genetic heterogeneity reflects the evolutionary history of a cancer and is thought to influence treatment outcomes. Here we report that a simple PCR-based assay interrogating somatic variation in hypermutable polyguanine (poly-G) repeats can provide a rapid and reliable assessment of mitotic history and clonal architecture in human cancer. We use poly-G repeat genotyping to study the evolution of colon carcinoma. In a cohort of 22 patients, we detect poly-G variants in 91% of tumors. Patient age is positively correlated with somatic mutation frequency, suggesting that some poly-G variants accumulate before the onset of carcinogenesis during normal division in colonic stem cells. Poorly differentiated tumors have fewer mutations than well-differentiated tumors, possibly indicating a shorter mitotic history of the founder cell in these cancers. We generate poly-G mutation profiles of spatially separated samples from primary carcinomas and matched metastases to build well-supported phylogenetic trees that illuminate individual patients’ path of metastatic progression. Our results show varying degrees of intratumor heterogeneity among patients. Finally, we show that poly-G mutations can be found in other cancers than colon carcinoma. Our approach can generate reliable maps of intratumor heterogeneity in large numbers of patients with minimal time and cost expenditure. PMID:24753616

  17. Parametric diagnosis of the adaptive gas path in the automatic control system of the aircraft engine

    NASA Astrophysics Data System (ADS)

    Kuznetsova, T. A.

    2017-01-01

    The paper dwells on the adaptive multimode mathematical model of the gas-turbine aircraft engine (GTE) embedded in the automatic control system (ACS). The mathematical model is based on the throttle performances, and is characterized by high accuracy of engine parameters identification in stationary and dynamic modes. The proposed on-board engine model is the state space linearized low-level simulation. The engine health is identified by the influence of the coefficient matrix. The influence coefficient is determined by the GTE high-level mathematical model based on measurements of gas-dynamic parameters. In the automatic control algorithm, the sum of squares of the deviation between the parameters of the mathematical model and real GTE is minimized. The proposed mathematical model is effectively used for gas path defects detecting in on-line GTE health monitoring. The accuracy of the on-board mathematical model embedded in ACS determines the quality of adaptive control and reliability of the engine. To improve the accuracy of identification solutions and sustainability provision, the numerical method of Monte Carlo was used. The parametric diagnostic algorithm based on the LPτ - sequence was developed and tested. Analysis of the results suggests that the application of the developed algorithms allows achieving higher identification accuracy and reliability than similar models used in practice.

  18. Isozygous and selectable marker-free MSTN knockout cloned pigs generated by the combined use of CRISPR/Cas9 and Cre/LoxP.

    PubMed

    Bi, Yanzhen; Hua, Zaidong; Liu, Ximei; Hua, Wenjun; Ren, Hongyan; Xiao, Hongwei; Zhang, Liping; Li, Li; Wang, Zhirui; Laible, Götz; Wang, Yan; Dong, Faming; Zheng, Xinmin

    2016-08-17

    Predictable, clean genetic modification (GM) in livestock is important for reliable phenotyping and biosafety. Here we reported the generation of isozygous, functional myostatin (MSTN) knockout cloned pigs free of selectable marker gene (SMG) by CRISPR/Cas9 and Cre/LoxP. CRISPR/Cas9-mediated homologous recombination (HR) was exploited to knock out (KO) one allele of MSTN in pig primary cells. Cre recombinase was then used to excise the SMG with an efficiency of 82.7%. The SMG-free non-EGFP cells were isolated by flow cytometery and immediately used as donor nuclei for nuclear transfer. A total of 685 reconstructed embryos were transferred into three surrogates with one delivering two male live piglets. Molecular testing verified the mono-allelic MSTN KO and SMG deletion in these cloned pigs. Western blots showed approximately 50% decrease in MSTN and concurrent increased expression of myogenic genes in muscle. Histological examination revealed the enhanced myofiber quantity but myofiber size remained unaltered. Ultrasonic detection showed the increased longissimus muscle size and decreased backfat thickness. Precision editing of pig MSTN gene has generated isozygous, SMG-free MSTN KO cloned founders, which guaranteed a reliable route for elite livestock production and a strategy to minimize potential biological risks.

  19. Inclusivity, exclusivity and limit of detection of commercially available real-time PCR assays for the detection of Salmonella.

    PubMed

    Margot, H; Stephan, R; Guarino, S; Jagadeesan, B; Chilton, D; O'Mahony, E; Iversen, C

    2013-08-01

    The traditional cultural detection of Salmonella spp. is both time- and labour-intensive. Salmonella is often a release criterion for the food industry and time to result is therefore an important factor. Storage of finished products and raw materials can be costly and may adversely impact available shelf-life. The application of real-time PCR for the detection of Salmonella spp. in food samples enables a potential time-saving of up to four days. The advancement of real-time PCR coupled with the development of commercially available systems in different formats has made this technology accessible for laboratories in an industrial environment. Ideally these systems are reliable and rapid as well as easy to use. The current study represents a comparative evaluation of seven commercial real-time PCR systems for the detection of Salmonella. Forty-nine target and twenty-nine non-target strains were included in the study to assess inclusivity and exclusivity. The limit of detection for each of the method was determined in four different food products. All systems evaluated were able to correctly identify the 49 Salmonella strains. Nevertheless, false positive results (Citrobacter spp.) were obtained with four of the seven systems. In milk powder and bouillon powder, the limit of detection was similar for all systems, suggesting a minimal matrix effect with these samples. Conversely, for black tea and cocoa powder some systems were prone to inhibition from matrix components. Up to 100% of the samples were inhibited using the proprietary extracts but inhibition could be reduced considerably by application of a DNA clean-up kit. Copyright © 2013 Elsevier B.V. All rights reserved.

  20. Accuracy and reliability of peer assessment of athletic training psychomotor laboratory skills.

    PubMed

    Marty, Melissa C; Henning, Jolene M; Willse, John T

    2010-01-01

    Peer assessment is defined as students judging the level or quality of a fellow student's understanding. No researchers have yet demonstrated the accuracy or reliability of peer assessment in athletic training education. To determine the accuracy and reliability of peer assessment of athletic training students' psychomotor skills. Cross-sectional study. Entry-level master's athletic training education program. First-year (n  =  5) and second-year (n  =  8) students. Participants evaluated 10 videos of a peer performing 3 psychomotor skills (middle deltoid manual muscle test, Faber test, and Slocum drawer test) on 2 separate occasions using a valid assessment tool. Accuracy of each peer-assessment score was examined through percentage correct scores. We used a generalizability study to determine how reliable athletic training students were in assessing a peer performing the aforementioned skills. Decision studies using generalizability theory demonstrated how the peer-assessment scores were affected by the number of participants and number of occasions. Participants had a high percentage of correct scores: 96.84% for the middle deltoid manual muscle test, 94.83% for the Faber test, and 97.13% for the Slocum drawer test. They were not able to reliably assess a peer performing any of the psychomotor skills on only 1 occasion. However, the φ increased (exceeding the 0.70 minimal standard) when 2 participants assessed the skill on 3 occasions (φ  =  0.79) for the Faber test, with 1 participant on 2 occasions (φ  =  0.76) for the Slocum drawer test, and with 3 participants on 2 occasions for the middle deltoid manual muscle test (φ  =  0.72). Although students did not detect all errors, they assessed their peers with an average of 96% accuracy. Having only 1 student assess a peer performing certain psychomotor skills was less reliable than having more than 1 student assess those skills on more than 1 occasion. Peer assessment of psychomotor skills could be an important part of the learning process and a tool to supplement instructor assessment.

  1. Determining Reliability of a Dual-Task Functional Mobility Protocol for Individuals With Lower Extremity Amputation.

    PubMed

    Hunter, Susan W; Frengopoulos, Courtney; Holmes, Jeff; Viana, Ricardo; Payne, Michael W

    2018-04-01

    To determine the relative and absolute reliability of a dual-task functional mobility assessment. Cross-sectional study. Academic rehabilitation hospital. Individuals (N=60) with lower extremity amputation attending an outpatient amputee clinic (mean age, 58.21±12.59y; 18, 80% male) who were stratified into 3 groups: (1) transtibial amputation of vascular etiology (n=20); (2) transtibial amputation of nonvascular etiology (n=20); and (3) transfemoral or bilateral amputation of any etiology (n=20). Not applicable. Time to complete the L Test measured functional mobility under single- and dual-task conditions. The addition of a cognitive task (serial subtractions by 3's) created dual-task conditions. Single-task performance on the cognitive task was also reported. Intraclass correlation coefficients (ICCs) measured relative reliability; SEM and minimal detectable change with a 95% confidence interval (MDC 95 ) measured absolute reliability. Bland-Altman plots measured agreement between assessments. Relative reliability results were excellent for all 3 groups. Values for the dual-task L Test for those with transtibial amputation of vascular etiology (n=20; mean age, 60.36±7.84y; 19, 90% men) were ICC=.98 (95% confidence interval [CI], .94-.99), SEM=1.36 seconds, and MDC 95 =3.76 seconds; for those with transtibial amputation of nonvascular etiology (n=20; mean age, 55.85±14.08y; 17, 85% men), values were ICC=.93 (95% CI, .80-.98), SEM=1.34 seconds, and MDC 95 =3.71 seconds; and for those with transfemoral or bilateral amputation (n=20; mean age, 58.21±14.88y; 13, 65% men), values were ICC=.998 (95% CI, .996-.999), SEM=1.03 seconds, and MDC 95 =2.85 seconds. Bland-Altman plots indicated that assessments did not vary systematically for each group. This dual-task assessment protocol achieved approved levels of relative reliability values for the 3 groups tested. This protocol may be used clinically or in research settings to assess the interaction between cognition and functional mobility in the population with lower extremity amputation. Copyright © 2018 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  2. Reliability-Based Electronics Shielding Design Tools

    NASA Technical Reports Server (NTRS)

    Wilson, J. W.; O'Neill, P. J.; Zang, T. A.; Pandolf, J. E.; Tripathi, R. K.; Koontz, Steven L.; Boeder, P.; Reddell, B.; Pankop, C.

    2007-01-01

    Shielding design on large human-rated systems allows minimization of radiation impact on electronic systems. Shielding design tools require adequate methods for evaluation of design layouts, guiding qualification testing, and adequate follow-up on final design evaluation.

  3. Green chemistry metrics

    EPA Science Inventory

    Synthetic chemists have always had an objective to achieve reliable and high-yielding routes to the syntheses of targeted molecules. The importance of minimal waste generation has emphasized the use of green chemistry principles and sustainable development. These directions lead ...

  4. Monoclonal antibody anti-MPO is useful in recognizing minimally differentiated acute myeloid leukaemia.

    PubMed

    Praxedes, M K; De Oliveira, L Z; Pereira, W da V; Quintana, I Z; Tabak, D G; De Oliveira, M S

    1994-01-01

    The enzyme myeloperoxidase (MPO) is the most specific marker of myeloid lineage. The recognition of acute myeloid leukaemia (AML) with minimally differentiation (AML-M0) is established with methods that include myeloid markers CD13/CD33 and detection of MPO in blast cells by immunological techniques or electron microscopy cytochemistry (EM). We have analysed the presence of MPO in leukaemic blast cells by conventional cytochemistry and immunological methods using a monoclonal antibody anti-MPO (CLB-MPO1) in 121 cases of acute leukaemia. The aim of the study was to investigate the sensitivity of this McAb to identify AML-M0, as CD13/CD33 can be expressed in some cases of acute lymphoblastic leukaemia (ALL) and EM cytochemistry is not always available in many laboratories. Anti-MPO was positive in all cases of AML (M1-M5) which were positive by Sudan Black B reaction in similar or higher percentage ratio for each case, although in some of them did not label with CD13/CD33 tested by IF and IPc techniques. Based on the anti-MPO positivity, 5 out of 10 cases called undifferentiated leukaemia (AUL) were reclassified as AML-M0, though 4 cases were CD13/CD33 negative. Furthermore, after analysing the anti-MPO expression among 32 cases of ALL, we had to reclassify four of them as acute biphenotypic leukaemia. We conclude that anti-MPO is a very sensitive and reliable tool in AML diagnosis and has an important role in distinguishing minimally differentiated AML and biphenotypic acute leukaemia from AUL and ALL.

  5. Enhancing malaria diagnosis through microfluidic cell enrichment and magnetic resonance relaxometry detection

    NASA Astrophysics Data System (ADS)

    Fook Kong, Tian; Ye, Weijian; Peng, Weng Kung; Wei Hou, Han; Marcos; Preiser, Peter Rainer; Nguyen, Nam-Trung; Han, Jongyoon

    2015-06-01

    Despite significant advancements over the years, there remains an urgent need for low cost diagnostic approaches that allow for rapid, reliable and sensitive detection of malaria parasites in clinical samples. Our previous work has shown that magnetic resonance relaxometry (MRR) is a potentially highly sensitive tool for malaria diagnosis. A key challenge for making MRR based malaria diagnostics suitable for clinical testing is the fact that MRR baseline fluctuation exists between individuals, making it difficult to detect low level parasitemia. To overcome this problem, it is important to establish the MRR baseline of each individual while having the ability to reliably determine any changes that are caused by the infection of malaria parasite. Here we show that an approach that combines the use of microfluidic cell enrichment with a saponin lysis before MRR detection can overcome these challenges and provide the basis for a highly sensitive and reliable diagnostic approach of malaria parasites. Importantly, as little as 0.0005% of ring stage parasites can be detected reliably, making this ideally suited for the detection of malaria parasites in peripheral blood obtained from patients. The approaches used here are envisaged to provide a new malaria diagnosis solution in the near future.

  6. Determining the Minimal Required Radioactivity of 18F-FDG for Reliable Semiquantification in PET/CT Imaging: A Phantom Study.

    PubMed

    Chen, Ming-Kai; Menard, David H; Cheng, David W

    2016-03-01

    In pursuit of as-low-as-reasonably-achievable (ALARA) doses, this study investigated the minimal required radioactivity and corresponding imaging time for reliable semiquantification in PET/CT imaging. Using a phantom containing spheres of various diameters (3.4, 2.1, 1.5, 1.2, and 1.0 cm) filled with a fixed (18)F-FDG concentration of 165 kBq/mL and a background concentration of 23.3 kBq/mL, we performed PET/CT at multiple time points over 20 h of radioactive decay. The images were acquired for 10 min at a single bed position for each of 10 half-lives of decay using 3-dimensional list mode and were reconstructed into 1-, 2-, 3-, 4-, 5-, and 10-min acquisitions per bed position using an ordered-subsets expectation maximum algorithm with 24 subsets and 2 iterations and a gaussian 2-mm filter. SUVmax and SUVavg were measured for each sphere. The minimal required activity (±10%) for precise SUVmax semiquantification in the spheres was 1.8 kBq/mL for an acquisition of 10 min, 3.7 kBq/mL for 3-5 min, 7.9 kBq/mL for 2 min, and 17.4 kBq/mL for 1 min. The minimal required activity concentration-acquisition time product per bed position was 10-15 kBq/mL⋅min for reproducible SUV measurements within the spheres without overestimation. Using the total radioactivity and counting rate from the entire phantom, we found that the minimal required total activity-time product was 17 MBq⋅min and the minimal required counting rate-time product was 100 kcps⋅min. Our phantom study determined a threshold for minimal radioactivity and acquisition time for precise semiquantification in (18)F-FDG PET imaging that can serve as a guide in pursuit of achieving ALARA doses. © 2016 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

  7. The reliability and effectiveness of an electromagnetic animal detection and driver warning system.

    DOT National Transportation Integrated Search

    2012-03-01

    "This report contains data on the reliability and effectiveness of an animal detection system project along US Hwy 160 : between Durango and Bayfield, Colorado. The system that was first installed was a Perimitrax system from Senstar : Corporation....

  8. Implementing a Microcontroller Watchdog with a Field-Programmable Gate Array (FPGA)

    NASA Technical Reports Server (NTRS)

    Straka, Bartholomew

    2013-01-01

    Reliability is crucial to safety. Redundancy of important system components greatly enhances reliability and hence safety. Field-Programmable Gate Arrays (FPGAs) are useful for monitoring systems and handling the logic necessary to keep them running with minimal interruption when individual components fail. A complete microcontroller watchdog with logic for failure handling can be implemented in a hardware description language (HDL.). HDL-based designs are vendor-independent and can be used on many FPGAs with low overhead.

  9. Strategies and Approaches to TPS Design

    NASA Technical Reports Server (NTRS)

    Kolodziej, Paul

    2005-01-01

    Thermal protection systems (TPS) insulate planetary probes and Earth re-entry vehicles from the aerothermal heating experienced during hypersonic deceleration to the planet s surface. The systems are typically designed with some additional capability to compensate for both variations in the TPS material and for uncertainties in the heating environment. This additional capability, or robustness, also provides a surge capability for operating under abnormal severe conditions for a short period of time, and for unexpected events, such as meteoroid impact damage, that would detract from the nominal performance. Strategies and approaches to developing robust designs must also minimize mass because an extra kilogram of TPS displaces one kilogram of payload. Because aircraft structures must be optimized for minimum mass, reliability-based design approaches for mechanical components exist that minimize mass. Adapting these existing approaches to TPS component design takes advantage of the extensive work, knowledge, and experience from nearly fifty years of reliability-based design of mechanical components. A Non-Dimensional Load Interference (NDLI) method for calculating the thermal reliability of TPS components is presented in this lecture and applied to several examples. A sensitivity analysis from an existing numerical simulation of a carbon phenolic TPS provides insight into the effects of the various design parameters, and is used to demonstrate how sensitivity analysis may be used with NDLI to develop reliability-based designs of TPS components.

  10. Calculus detection calibration among dental hygiene faculty members utilizing dental endoscopy: a pilot study.

    PubMed

    Partido, Brian B; Jones, Archie A; English, Dana L; Nguyen, Carol A; Jacks, Mary E

    2015-02-01

    Dental and dental hygiene faculty members often do not provide consistent instruction in the clinical environment, especially in tasks requiring clinical judgment. From previous efforts to calibrate faculty members in calculus detection using typodonts, researchers have suggested using human subjects and emerging technology to improve consistency in clinical instruction. The purpose of this pilot study was to determine if a dental endoscopy-assisted training program would improve intra- and interrater reliability of dental hygiene faculty members in calculus detection. Training included an ODU 11/12 explorer, typodonts, and dental endoscopy. A convenience sample of six participants was recruited from the dental hygiene faculty at a California community college, and a two-group randomized experimental design was utilized. Intra- and interrater reliability was measured before and after calibration training. Pretest and posttest Kappa averages of all participants were compared using repeated measures (split-plot) ANOVA to determine the effectiveness of the calibration training on intra- and interrater reliability. The results showed that both kinds of reliability significantly improved for all participants and the training group improved significantly in interrater reliability from pretest to posttest. Calibration training was beneficial to these dental hygiene faculty members, especially those beginning with less than full agreement. This study suggests that calculus detection calibration training utilizing dental endoscopy can effectively improve interrater reliability of dental and dental hygiene clinical educators. Future studies should include human subjects, involve more participants at multiple locations, and determine whether improved rater reliability can be sustained over time.

  11. Reliability-Based Control Design for Uncertain Systems

    NASA Technical Reports Server (NTRS)

    Crespo, Luis G.; Kenny, Sean P.

    2005-01-01

    This paper presents a robust control design methodology for systems with probabilistic parametric uncertainty. Control design is carried out by solving a reliability-based multi-objective optimization problem where the probability of violating design requirements is minimized. Simultaneously, failure domains are optimally enlarged to enable global improvements in the closed-loop performance. To enable an efficient numerical implementation, a hybrid approach for estimating reliability metrics is developed. This approach, which integrates deterministic sampling and asymptotic approximations, greatly reduces the numerical burden associated with complex probabilistic computations without compromising the accuracy of the results. Examples using output-feedback and full-state feedback with state estimation are used to demonstrate the ideas proposed.

  12. Technical information report: Plasma melter operation, reliability, and maintenance analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hendrickson, D.W.

    1995-03-14

    This document provides a technical report of operability, reliability, and maintenance of a plasma melter for low-level waste vitrification, in support of the Hanford Tank Waste Remediation System (TWRS) Low-Level Waste (LLW) Vitrification Program. A process description is provided that minimizes maintenance and downtime and includes material and energy balances, equipment sizes and arrangement, startup/operation/maintence/shutdown cycle descriptions, and basis for scale-up to a 200 metric ton/day production facility. Operational requirements are provided including utilities, feeds, labor, and maintenance. Equipment reliability estimates and maintenance requirements are provided which includes a list of failure modes, responses, and consequences.

  13. Summary of NASA Aerospace Flight Battery Systems Program activities

    NASA Technical Reports Server (NTRS)

    Manzo, Michelle; Odonnell, Patricia

    1994-01-01

    A summary of NASA Aerospace Flight Battery Systems Program Activities is presented. The NASA Aerospace Flight Battery Systems Program represents a unified NASA wide effort with the overall objective of providing NASA with the policy and posture which will increase the safety, performance, and reliability of space power systems. The specific objectives of the program are to: enhance cell/battery safety and reliability; maintain current battery technology; increase fundamental understanding of primary and secondary cells; provide a means to bring forth advanced technology for flight use; assist flight programs in minimizing battery technology related flight risks; and ensure that safe, reliable batteries are available for NASA's future missions.

  14. Investigation of reliability indicators of information analysis systems based on Markov’s absorbing chain model

    NASA Astrophysics Data System (ADS)

    Gilmanshin, I. R.; Kirpichnikov, A. P.

    2017-09-01

    In the result of study of the algorithm of the functioning of the early detection module of excessive losses, it is proven the ability to model it by using absorbing Markov chains. The particular interest is in the study of probability characteristics of early detection module functioning algorithm of losses in order to identify the relationship of indicators of reliability of individual elements, or the probability of occurrence of certain events and the likelihood of transmission of reliable information. The identified relations during the analysis allow to set thresholds reliability characteristics of the system components.

  15. Reliability and validity of the cross-culturally adapted Turkish version of the Core Outcome Measures Index for low back pain.

    PubMed

    Çetin, Engin; Çelik, Evrim Coşkun; Acaroğlu, Emre; Berk, Haluk

    2018-01-01

    To produce a cross-culturally adapted and validated Turkish version of The Core Outcome Measure Index (COMI) Back questionnaire. Ninety-six Turkish-speaking patients with non-specific low back pain (LBP) were recruited from orthopedic and physical therapy outpatient clinics in a public hospital. They completed a booklet of questionnaires containing Turkish version of COMI, adjectival pain scale, Roland Morris disability questionnaire, European 5 Dimension Questionnaire and brief version of World Health Organization Quality of Life Questionnaire. Within following 7-14 days, 67 patients, reported no or minimal changes in their back pain status, completed the Turkish COMI again to assess reproducibility. Data quality was good with very few missing answers. COMI summary index score displayed 3% floor effects and no ceiling effects. The correlations between the COMI summary index score and each of the full instrument whole scores were found to be excellent to very good (ρ = - 0.81 to 0.74). Reliability expressed as intraclass correlation coefficient (ICC) was 0.95 (95% CI 0.91-0.97). Standard error of measurement (SEM agreement ) was acceptable at 0.41 and the minimum detectable change (MDC 95% ) was 1.14. Turkish version of the COMI has acceptable psychometric properties. It is a valid and reliable instrument and cross-culturally adapted, in accordance with established guidelines, for the use by Turkish-speaking patients. It can be recommended for use in evaluation of patients with chronic LBP in daily practice, in international multicenter studies and in spine registry systems.

  16. Feasibility study of using a Microsoft Kinect for virtual coaching of wheelchair transfer techniques.

    PubMed

    Hwang, Seonhong; Tsai, Chung-Ying; Koontz, Alicia M

    2017-05-24

    The purpose of this study was to test the concurrent validity and test-retest reliability of the Kinect skeleton tracking algorithm for measurement of trunk, shoulder, and elbow joint angle measurement during a wheelchair transfer task. Eight wheelchair users were recruited for this study. Joint positions were recorded simultaneously by the Kinect and Vicon motion capture systems while subjects transferred from their wheelchairs to a level bench. Shoulder, elbow, and trunk angles recorded with the Kinect system followed a similar trajectory as the angles recorded with the Vicon system with correlation coefficients that are larger than 0.71 on both sides (leading arm and trailing arm). The root mean square errors (RMSEs) ranged from 5.18 to 22.46 for the shoulder, elbow, and trunk angles. The 95% limits of agreement (LOA) for the discrepancy between the two systems exceeded the clinical significant level of 5°. For the trunk, shoulder, and elbow angles, the Kinect had very good relative reliability for the measurement of sagittal, frontal and horizontal trunk angles, as indicated by the high intraclass correlation coefficient (ICC) values (>0.90). Small standard error of the measure (SEM) values, indicating good absolute reliability, were observed for all joints except for the leading arm's shoulder joint. Relatively large minimal detectable changes (MDCs) were observed in all joint angles. The Kinect motion tracking has promising performance levels for some upper limb joints. However, more accurate measurement of the joint angles may be required. Therefore, understanding the limitations in precision and accuracy of Kinect is imperative before utilization of Kinect.

  17. A fast and reliable readout method for quantitative analysis of surface-enhanced Raman scattering nanoprobes on chip surface

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chang, Hyejin; Jeong, Sinyoung; Ko, Eunbyeol

    2015-05-15

    Surface-enhanced Raman scattering techniques have been widely used for bioanalysis due to its high sensitivity and multiplex capacity. However, the point-scanning method using a micro-Raman system, which is the most common method in the literature, has a disadvantage of extremely long measurement time for on-chip immunoassay adopting a large chip area of approximately 1-mm scale and confocal beam point of ca. 1-μm size. Alternative methods such as sampled spot scan with high confocality and large-area scan method with enlarged field of view and low confocality have been utilized in order to minimize the measurement time practically. In this study, wemore » analyzed the two methods in respect of signal-to-noise ratio and sampling-led signal fluctuations to obtain insights into a fast and reliable readout strategy. On this basis, we proposed a methodology for fast and reliable quantitative measurement of the whole chip area. The proposed method adopted a raster scan covering a full area of 100 μm × 100 μm region as a proof-of-concept experiment while accumulating signals in the CCD detector for single spectrum per frame. One single scan with 10 s over 100 μm × 100 μm area yielded much higher sensitivity compared to sampled spot scanning measurements and no signal fluctuations attributed to sampled spot scan. This readout method is able to serve as one of key technologies that will bring quantitative multiplexed detection and analysis into practice.« less

  18. MERCURY MEASUREMENTS USING DIRECT-ANALYZER METHODOLOGY

    EPA Science Inventory

    Under EPA's Water Quality Research Program, exposure studies are needed to determine how well control strategies and guidance are working. Consequently, reliable and convenient techniques that minimize waste production are of special interest. While traditional methods for determ...

  19. Some Improvements in Utilization of Flash Memory Devices

    NASA Technical Reports Server (NTRS)

    Gender, Thomas K.; Chow, James; Ott, William E.

    2009-01-01

    Two developments improve the utilization of flash memory devices in the face of the following limitations: (1) a flash write element (page) differs in size from a flash erase element (block), (2) a block must be erased before its is rewritten, (3) lifetime of a flash memory is typically limited to about 1,000,000 erases, (4) as many as 2 percent of the blocks of a given device may fail before the expected end of its life, and (5) to ensure reliability of reading and writing, power must not be interrupted during minimum specified reading and writing times. The first development comprises interrelated software components that regulate reading, writing, and erasure operations to minimize migration of data and unevenness in wear; perform erasures during idle times; quickly make erased blocks available for writing; detect and report failed blocks; maintain the overall state of a flash memory to satisfy real-time performance requirements; and detect and initialize a new flash memory device. The second development is a combination of hardware and software that senses the failure of a main power supply and draws power from a capacitive storage circuit designed to hold enough energy to sustain operation until reading or writing is completed.

  20. Miniaturized, multibeam, solid state scanning laser radar in automobile collision avoidance sensor systems

    NASA Astrophysics Data System (ADS)

    Sargent, Ronald A.

    1995-06-01

    Recent intelligent transportation systems (ITS) initiatives sponsored by commercial transportation companies and the U.S. Department of Transportation include an area dedicated to Automated Vehicle Control Systems (AVCS). AVCS systems are dedicated to improving passenger automobile safety, efficiency, and impact on the environment. Minimizing the number of automobile collisions through automated obstacle detection and vehicle response is vital to this effort. Simple, reliable, low cost sensors installed in automobiles to provide driver warning and/or input to vehicle systems such as braking or cruise control are the key piece to making this technology as common as air bags and seat belts. EPA emission regulations now require specific areas to periodically report the mix of vehicle types. These reports must include in the mix the 13 possible categories for vehicles. Simple low cost senors installed as part of the traffic management system will facilitate the determination of vehicle category. Laser Atlanta has recently developed two distinct types of sensors that utilize a unique multi- beam approach to detect `targets' that are potential hazards. They also provide range and range rate data to automobile control and traffic management systems.

  1. Determination of esters in glycerol phase after transesterification of vegetable oil.

    PubMed

    Hájek, Martin; Skopal, Frantisek; Kwiecien, Jirí; Cernoch, Michal

    2010-06-30

    In biodiesel production, glycerol is formed as a side product and it is contained in the glycerol phase. This phase contains (besides glycerol): water, soaps, alcohol, traces of catalyst and glycerides and the remaining esters. In this paper, a new method for the determination of esters in the glycerol phase is introduced. The determination enables the minimization of the losses of biodiesel within the production process. It is based on the gradient RP-LC method (water and acetonitrile) with refractometric detection. The analysis is easy and the samples do not need any treatment (only dilution by water) and has a low detection limit. The results of this method were compared with the results of two other published methods: isocratic HPLC and GC. The disadvantage of these two methods is that they need extensive treatment of the sample, which takes many hours, and they are able to determine only the sum of esters. The new method is reliable, much faster and able to differentiate esters of almost each higher fatty acid (e.g. linoleic, linolenic, strearic alkyl ester) in the glycerol phase. Copyright 2010 Elsevier B.V. All rights reserved.

  2. Detection of the Odor Signature of Ovarian Cancer using DNA-Decorated Carbon Nanotube Field Effect Transistor Arrays

    NASA Astrophysics Data System (ADS)

    Kehayias, Christopher; Kybert, Nicholas; Yodh, Jeremy; Johnson, A. T. Charlie

    Carbon nanotubes are low-dimensional materials that exhibit remarkable chemical and bio-sensing properties and have excellent compatibility with electronic systems. Here, we present a study that uses an electronic olfaction system based on a large array of DNA-carbon nanotube field effect transistors vapor sensors to analyze the VOCs of blood plasma samples collected from patients with malignant ovarian cancer, patients with benign ovarian lesions, and age-matched healthy subjects. Initial investigations involved coating each CNT sensor with single-stranded DNA of a particular base sequence. 10 distinct DNA oligomers were used to functionalize the carbon nanotube field effect transistors, providing a 10-dimensional sensor array output response. Upon performing a statistical analysis of the 10-dimensional sensor array responses, we showed that blood samples from patients with malignant cancer can be reliably differentiated from those of healthy control subjects with a p-value of 3 x 10-5. The results provide preliminary evidence that the blood of ovarian cancer patients contains a discernable volatile chemical signature that can be detected using DNA-CNT nanoelectronic vapor sensors, a first step towards a minimally invasive electronic diagnostic technology for ovarian cancer.

  3. Historical Building Monitoring Using an Energy-Efficient Scalable Wireless Sensor Network Architecture

    PubMed Central

    Capella, Juan V.; Perles, Angel; Bonastre, Alberto; Serrano, Juan J.

    2011-01-01

    We present a set of novel low power wireless sensor nodes designed for monitoring wooden masterpieces and historical buildings, in order to perform an early detection of pests. Although our previous star-based system configuration has been in operation for more than 13 years, it does not scale well for sensorization of large buildings or when deploying hundreds of nodes. In this paper we demonstrate the feasibility of a cluster-based dynamic-tree hierarchical Wireless Sensor Network (WSN) architecture where realistic assumptions of radio frequency data transmission are applied to cluster construction, and a mix of heterogeneous nodes are used to minimize economic cost of the whole system and maximize power saving of the leaf nodes. Simulation results show that the specialization of a fraction of the nodes by providing better antennas and some energy harvesting techniques can dramatically extend the life of the entire WSN and reduce the cost of the whole system. A demonstration of the proposed architecture with a new routing protocol and applied to termite pest detection has been implemented on a set of new nodes and should last for about 10 years, but it provides better scalability, reliability and deployment properties. PMID:22346630

  4. Clinical characteristics of occult macular dystrophy in family with mutation of RP1l1 gene.

    PubMed

    Tsunoda, Kazushige; Usui, Tomoaki; Hatase, Tetsuhisa; Yamai, Satoshi; Fujinami, Kaoru; Hanazono, Gen; Shinoda, Kei; Ohde, Hisao; Akahori, Masakazu; Iwata, Takeshi; Miyake, Yozo

    2012-06-01

    To report the clinical characteristics of occult macular dystrophy (OMD) in members of one family with a mutation of the RP1L1 gene. Fourteen members with a p.Arg45Trp mutation in the RP1L1 gene were examined. The visual acuity, visual fields, fundus photographs, fluorescein angiograms, full-field electroretinograms, multifocal electroretinograms, and optical coherence tomographic images were examined. The clinical symptoms and signs and course of the disease were documented. All the members with the RP1L1 mutation except one woman had ocular symptoms and signs of OMD. The fundus was normal in all the patients during the entire follow-up period except in one patient with diabetic retinopathy. Optical coherence tomography detected the early morphologic abnormalities both in the photoreceptor inner/outer segment line and cone outer segment tip line. However, the multifocal electroretinograms were more reliable in detecting minimal macular dysfunction at an early stage of OMD. The abnormalities in the multifocal electroretinograms and optical coherence tomography observed in the OMD patients of different durations strongly support the contribution of RP1L1 mutation to the presence of this disease.

  5. Historical building monitoring using an energy-efficient scalable wireless sensor network architecture.

    PubMed

    Capella, Juan V; Perles, Angel; Bonastre, Alberto; Serrano, Juan J

    2011-01-01

    We present a set of novel low power wireless sensor nodes designed for monitoring wooden masterpieces and historical buildings, in order to perform an early detection of pests. Although our previous star-based system configuration has been in operation for more than 13 years, it does not scale well for sensorization of large buildings or when deploying hundreds of nodes. In this paper we demonstrate the feasibility of a cluster-based dynamic-tree hierarchical Wireless Sensor Network (WSN) architecture where realistic assumptions of radio frequency data transmission are applied to cluster construction, and a mix of heterogeneous nodes are used to minimize economic cost of the whole system and maximize power saving of the leaf nodes. Simulation results show that the specialization of a fraction of the nodes by providing better antennas and some energy harvesting techniques can dramatically extend the life of the entire WSN and reduce the cost of the whole system. A demonstration of the proposed architecture with a new routing protocol and applied to termite pest detection has been implemented on a set of new nodes and should last for about 10 years, but it provides better scalability, reliability and deployment properties.

  6. A Concept for a Mobile Remote Manipulator System

    NASA Technical Reports Server (NTRS)

    Mikulus, M. M., Jr.; Bush, H. G.; Wallsom, R. E.; Jensen, J. K.

    1985-01-01

    A conceptual design for a Mobile Remote Manipulator System (MRMS) is presented. This concept does not require continuous rails for mobility (only guide pins at truss hardpoints) and is very compact, being only one bay square. The MRMS proposed is highly maneuverable and is able to move in any direction along the orthogonal guide pin array under complete control at all times. The proposed concept would greatly enhance the safety and operational capabilities of astronauts performing EVA functions such as structural assembly, payload transport and attachment, space station maintenance, repair or modification, and future spacecraft construction or servicing. The MRMS drive system conceptual design presented is a reasonably simple mechanical device which can be designed to exhibit high reliability. Developmentally, all components of the proposed MRMS either exist or are considered to be completely state of the art designs requiring minimal development, features which should enhance reliability and minimize costs.

  7. Investigation of Desiccants and CO2 Sorbents for Exploration Systems 2016-2017

    NASA Technical Reports Server (NTRS)

    Knox, James C.; Watson, David W.; Giesy, Timothy J.; Cmarik, Gregory E.; Miller, Lee A.

    2017-01-01

    NASA has embarked on the mission to enable humans to explore deep space, including the goal of sending humans to Mars. This journey will require significant developments in a wide range of technical areas as resupply and early return are not possible. Additionally, mass, power, and volume must be minimized for all phases to maximize propulsion availability. Among the critical areas identified for development are life support systems, which will require increases in reliability as well as reduce resource usage. Two primary points for reliability are the mechanical stability of sorbent pellets and recovery of CO2 sorbent productivity after off-nominal events. In this paper, we discuss the present efforts towards screening and characterizing commercially-available sorbents for extended operation in desiccant and CO2 removal beds. With minimized dusting as the primary criteria, a commercial 13X zeolite was selected and tested for performance and risk.

  8. Ultrasensitive Genotypic Detection of Antiviral Resistance in Hepatitis B Virus Clinical Isolates▿ †

    PubMed Central

    Fang, Jie; Wichroski, Michael J.; Levine, Steven M.; Baldick, Carl J.; Mazzucco, Charles E.; Walsh, Ann W.; Kienzle, Bernadette K.; Rose, Ronald E.; Pokornowski, Kevin A.; Colonno, Richard J.; Tenney, Daniel J.

    2009-01-01

    Amino acid substitutions that confer reduced susceptibility to antivirals arise spontaneously through error-prone viral polymerases and are selected as a result of antiviral therapy. Resistance substitutions first emerge in a fraction of the circulating virus population, below the limit of detection by nucleotide sequencing of either the population or limited sets of cloned isolates. These variants can expand under drug pressure to dominate the circulating virus population. To enhance detection of these viruses in clinical samples, we established a highly sensitive quantitative, real-time allele-specific PCR assay for hepatitis B virus (HBV) DNA. Sensitivity was accomplished using a high-fidelity DNA polymerase and oligonucleotide primers containing locked nucleic acid bases. Quantitative measurement of resistant and wild-type variants was accomplished using sequence-matched standards. Detection methodology that was not reliant on hybridization probes, and assay modifications, minimized the effect of patient-specific sequence polymorphisms. The method was validated using samples from patients chronically infected with HBV through parallel sequencing of large numbers of cloned isolates. Viruses with resistance to lamivudine and other l-nucleoside analogs and entecavir, involving 17 different nucleotide substitutions, were reliably detected at levels at or below 0.1% of the total population. The method worked across HBV genotypes. Longitudinal analysis of patient samples showed earlier emergence of resistance on therapy than was seen with sequencing methodologies, including some cases of resistance that existed prior to treatment. In summary, we established and validated an ultrasensitive method for measuring resistant HBV variants in clinical specimens, which enabled earlier, quantitative measurement of resistance to therapy. PMID:19433559

  9. Development of a fast and efficient method for hepatitis A virus concentration from green onion.

    PubMed

    Zheng, Yan; Hu, Yuan

    2017-11-01

    Hepatitis A virus (HAV) can cause serious liver disease and even death. HAV outbreaks are associated with the consumption of raw or minimally processed produce, making it a major public health concern. Infections have occurred despite the fact that effective HAV vaccine has been available. Development of a rapid and sensitive HAV detection method is necessary for an investigation of an HAV outbreak. Detection of HAV is complicated by the lack of a reliable culture method. In addition, due to the low infectious dose of HAV, these methods must be very sensitive. Current methods rely on efficient sample preparation and concentration steps followed by sensitive molecular detection techniques. Using green onions which was involved in most recent HAV outbreaks as a representative produce, a method of capturing virus particles was developed using carboxyl-derivatized magnetic beads in this study. Carboxyl beads, like antibody-coated beads or cationic beads, detect HAV at a level as low as 100 pfu/25g of green onions. RNA from virus concentrated in this manner can be released by heat-shock (98°C 5min) for molecular detection without sacrificing sensitivity. Bypassing the RNA extraction procedure saves time and removes multiple manipulation steps, which makes large scale HAV screening possible. In addition, the inclusion of beef extract and pectinase rather than NP40 in the elution buffer improved the HAV liberation from the food matrix over current methods by nearly 10 fold. The method proposed in this study provides a promising tool to improve food risk assessment and protect public health. Published by Elsevier B.V.

  10. A Novel Addressing Scheme for PMIPv6 Based Global IP-WSNs

    PubMed Central

    Islam, Md. Motaharul; Huh, Eui-Nam

    2011-01-01

    IP based Wireless Sensor Networks (IP-WSNs) are being used in healthcare, home automation, industrial control and agricultural monitoring. In most of these applications global addressing of individual IP-WSN nodes and layer-three routing for mobility enabled IP-WSN with special attention to reliability, energy efficiency and end to end delay minimization are a few of the major issues to be addressed. Most of the routing protocols in WSN are based on layer-two approaches. For reliability and end to end communication enhancement the necessity of layer-three routing for IP-WSNs is generating significant attention among the research community, but due to the hurdle of maintaining routing state and other communication overhead, it was not possible to introduce a layer-three routing protocol for IP-WSNs. To address this issue we propose in this paper a global addressing scheme and layer-three based hierarchical routing protocol. The proposed addressing and routing approach focuses on all the above mentioned issues. Simulation results show that the proposed addressing and routing approach significantly enhances the reliability, energy efficiency and end to end delay minimization. We also present architecture, message formats and different routing scenarios in this paper. PMID:22164084

  11. A novel addressing scheme for PMIPv6 based global IP-WSNs.

    PubMed

    Islam, Md Motaharul; Huh, Eui-Nam

    2011-01-01

    IP based Wireless Sensor Networks (IP-WSNs) are being used in healthcare, home automation, industrial control and agricultural monitoring. In most of these applications global addressing of individual IP-WSN nodes and layer-three routing for mobility enabled IP-WSN with special attention to reliability, energy efficiency and end to end delay minimization are a few of the major issues to be addressed. Most of the routing protocols in WSN are based on layer-two approaches. For reliability and end to end communication enhancement the necessity of layer-three routing for IP-WSNs is generating significant attention among the research community, but due to the hurdle of maintaining routing state and other communication overhead, it was not possible to introduce a layer-three routing protocol for IP-WSNs. To address this issue we propose in this paper a global addressing scheme and layer-three based hierarchical routing protocol. The proposed addressing and routing approach focuses on all the above mentioned issues. Simulation results show that the proposed addressing and routing approach significantly enhances the reliability, energy efficiency and end to end delay minimization. We also present architecture, message formats and different routing scenarios in this paper.

  12. Design optimization of a fuzzy distributed generation (DG) system with multiple renewable energy sources

    NASA Astrophysics Data System (ADS)

    Ganesan, T.; Elamvazuthi, I.; Shaari, Ku Zilati Ku; Vasant, P.

    2012-09-01

    The global rise in energy demands brings major obstacles to many energy organizations in providing adequate energy supply. Hence, many techniques to generate cost effective, reliable and environmentally friendly alternative energy source are being explored. One such method is the integration of photovoltaic cells, wind turbine generators and fuel-based generators, included with storage batteries. This sort of power systems are known as distributed generation (DG) power system. However, the application of DG power systems raise certain issues such as cost effectiveness, environmental impact and reliability. The modelling as well as the optimization of this DG power system was successfully performed in the previous work using Particle Swarm Optimization (PSO). The central idea of that work was to minimize cost, minimize emissions and maximize reliability (multi-objective (MO) setting) with respect to the power balance and design requirements. In this work, we introduce a fuzzy model that takes into account the uncertain nature of certain variables in the DG system which are dependent on the weather conditions (such as; the insolation and wind speed profiles). The MO optimization in a fuzzy environment was performed by applying the Hopfield Recurrent Neural Network (HNN). Analysis on the optimized results was then carried out.

  13. Real-time detection system for tumor localization during minimally invasive surgery for gastric and colon cancer removal: In vivo feasibility study in a swine model.

    PubMed

    Choi, Won Jung; Moon, Jin-Hee; Min, Jae Seok; Song, Yong Keun; Lee, Seung A; Ahn, Jin Woo; Lee, Sang Hun; Jung, Ha Chul

    2018-03-01

    During minimally invasive surgery (MIS), it is impossible to directly detect marked clips around tumors via palpation. Therefore, we developed a novel method and device using Radio Frequency IDentification (RFID) technology to detect the position of clips during minimally invasive gastrectomy or colectomy. The feasibility of the RFID-based detection system was evaluated in an animal experiment consisting of seven swine. The primary outcome was to successfully detect the location of RFID clips in the stomach and colon. The secondary outcome measures were to detect time (time during the intracorporeal detection of the RFID clip), and accuracy (distance between the RFID clip and the detected site). A total of 25 detection attempts (14 in the stomach and 11 in the colon) using the RFID antenna had a 100% success rate. The median detection time was 32.5 s (range, 15-119 s) for the stomach and 28.0 s (range, 8-87 s) for the colon. The median detection distance was 6.5 mm (range, 4-18 mm) for the stomach and 6.0 mm (range, 3-13 mm) for the colon. We demonstrated favorable results for a RFID system that detects the position of gastric and colon tumors in real-time during MIS. © 2017 Wiley Periodicals, Inc.

  14. Transsternal surgical biopsy of a mediastinal mass under local anesthesia.

    PubMed

    Bedini, Amedeo Vittorio; Libretti, Lidia; Pirondini, Emanuele

    2013-01-01

    We describe a minimally invasive transsternal surgical approach to obtain biopsies from retrosternal masses under local anesthesia. This original procedure was carried out in a patient with superior vena cava syndrome because she was unfit to undergo a CT-guided biopsy and at high risk for narcosis. In patients with such features this procedure could be preferable to conventional techniques. The transsternal approach is reliable, produces minimal trauma and no risk of pleural or vessel injury, and is very fast.

  15. The Presto 1000: A novel automated transcranial Doppler ultrasound system.

    PubMed

    Han, Seunggu J; Rutledge, William Caleb; Englot, Dario J; Winkler, Ethan A; Browne, Janet L; Pflugrath, Lauren; Cronsier, David; Abla, Adib A; Kliot, Michel; Lawton, Michael T

    2015-11-01

    We examined the reliability and ease of use of a novel automated transcranial Doppler (TCD) system in comparison to a conventional TCD system. TCD ultrasound allows non-invasive monitoring of cerebral blood flow, and can predict arterial vasospasm after a subarachnoid hemorrhage (SAH). The Presto 1000 TCD system (PhysioSonics, Bellevue, WA, USA) is designed for monitoring flow through the M1 segment of the middle cerebral artery (MCA) via temporal windows. The Presto 1000 system was tested across multiple preclinical and clinical settings in parallel with a control predicate TCD system. In a phantom flow generating device, both the Presto 1000 and Spencer system (Spencer Technologies, Redmond, WA, USA) were able to detect velocities with high accuracy. In nine volunteer patients, the Presto system was able to locate the MCA in 14 out of 18 temporal windows, in an average of 12.5s. In the SAH cohort of five patients with a total of 25 paired measurements, the mean absolute difference in flow velocities of the M1 segment, as measured by the two systems, was 17.5 cm/s. These data suggest that the Presto system offers an automated TCD that can reliably localize and detect flow of the MCA, with relative ease of use. The system carries the additional benefit of requiring minimal training for the operator, and can be used by many providers across multiple bedside settings. The mean velocities that were generated warrant further validation across an extended group of patients, and the predictive value for vasospasm should be checked against the current standard of angiography. Copyright © 2015 Elsevier Ltd. All rights reserved.

  16. The ``Leakage Current Sentinel'': A novel plug-in socket device for online biomedical equipment electrical safety surveillance

    NASA Astrophysics Data System (ADS)

    Cappa, Paolo; Marinozzi, Franco; Sciuto, Salvatore Andrea

    2000-07-01

    The Leakage Current Sentinel (LCS) has been designed and implemented for the detection of hazardous situations caused by dangerous earth leakage current values in intensive care units and operating theaters. The device, designed and manufactured with full compliance of the high risk environment requirements, is able to monitor online the earth leakage current and detect ground wire faults. Operation utilizes a microammeter with an overall sensitivity of 2.5×104 V/A. In order to assure the reliability of the device in providing alarm signals, the simultaneous presence of absorbed power current is monitored by means of another ammeter with decreased sensitivity (3.0 V/A). The measured root mean square current values are compared with reference values in order to send signals to NAND and OR complementary metal-oxide-semiconductor gates to enable audible and visible alarms according to the possible hazardous cases examined in the article. The final LCS packaging was shaped as a wall socket adapter for common electromedical device power cord plugs, with particular attention to minimizing its dimensions and to provide analog voltage outputs for both measured leakage and power currents, in order to allow automatic data acquisition and computerized hazardous situation management. Finally, a personal computer based automatic measuring system has been configured to simultaneously monitor several LCSs installed in the same intensive care unit room and, as a consequence, to distinguish different hazardous scenarios and provide an adequate alert to the clinical personnel whose final decision is still required. The test results confirm the effectiveness and reliability of the LCS in giving an alert in case of leakage current anomalous values, either in case of a ground fault or in case of a dangerous leakage current.

  17. Cross-cultural adaptation and measurement properties of the Brazilian Portuguese Version of the Victorian Institute of Sport Assessment-Patella (VISA-P) scale.

    PubMed

    Wageck, Bruna Borges; de Noronha, Marcos; Lopes, Alexandre Dias; da Cunha, Ronaldo Alves; Takahashi, Ricardo Hisayoshi; Costa, Leonardo Oliveira Pena

    2013-03-01

    Clinical measurement. To translate, adapt, and test the measurement properties of the Brazilian Portuguese version of the Victorian Institute of Sport Assessment-Patella (VISA-P) questionnaire. It is important to objectively measure symptoms and functional limitations related to patellar tendinopathy using outcome measures that have been validated in the language of the target population. Cross-cultural adaptations are also useful to enhance the understanding of the measurement properties of an assessment tool, regardless of the target language. The VISA-P questionnaire was translated into Brazilian Portuguese, culturally adapted, and titled VISA-P Brazil. It was then administered on 2 occasions with a 24- to 48-hour interval between them, and a third time after a month of physical therapy treatment. The following measurement properties were analyzed: internal consistency, test-retest reliability, agreement, construct validity, floor and ceiling effects, and responsiveness. The VISA-P Brazil had high internal consistency (Cronbach α = .76; if item deleted, Cronbach α = .69-.78), excellent reliability and agreement (intraclass correlation coefficient = 0.91; 95% confidence interval: 0.85, 0.95; standard error of measurement, 5.2 points; minimal detectable change at the 90% confidence level, 12.2 points), and good construct validity (Pearson r = 0.60 compared to Lysholm). No ceiling and floor effects were detected for the VISA-P Brazil, and the responsiveness, based on 32 patients receiving physical therapy intervention for 1 month, demonstrated a large effect size of 0.97 (95% confidence interval: 0.68, 1.25). The VISA-P Brazil is a reproducible and responsive tool and can be used in clinical practice and research to assess the severity of pain and disability of patients with patellar tendinopathy.

  18. Autism Screening With Online Decision Support by Primary Care Pediatricians Aided by M-CHAT/F.

    PubMed

    Sturner, Raymond; Howard, Barbara; Bergmann, Paul; Morrel, Tanya; Andon, Lindsay; Marks, Danielle; Rao, Patricia; Landa, Rebecca

    2016-09-01

    Autism spectrum disorders (ASDs) often go undetected in toddlers. The Modified Checklist for Autism in Toddlers (M-CHAT) With Follow-up Interview (M-CHAT/F) has been shown to improve detection and reduce over-referral. However, there is little evidence supporting the administration of the interview by a primary care pediatrician (PCP) during typical checkups. The goal of this study was to evaluate the feasibility, validity, and reliability of the M-CHAT/F by PCPs with online prompts at the time of a positive M-CHAT screen. Forty-seven PCPs from 22 clinics completed 197 M-CHAT/Fs triggered by positive M-CHAT screens via the same secure Web-based platform that parents used to complete M-CHATs before an 18- or 24-month well-child visit. A second M-CHAT/F was administered live or by telephone by trained research assistants (RAs) at the Kennedy Krieger Institute Center for Autism and Related Disorders. The Autism Diagnostic Observation Schedule, Second Edition, and the Mullen Scales of Early Learning were administered as criterion measures. Measures of agreement between PCPs and RAs were calculated, and measures of test performance compared. There was 86.6% agreement between PCPs and RAs, with a Cohen's κ of 0.72. Comparison of sensitivity, specificity, positive predictive value (PPV), and overall accuracy for M-CHAT/F between PCPs and RAs showed significant equivalence for all measures. Use of the M-CHAT/F by PCPs resulted in significant improvement in PPV compared with the M-CHAT alone. Minimally trained PCPs can administer the M-CHAT/F reliably and efficiently during regular well-child visits, increasing PPV without compromising detection. Copyright © 2016 by the American Academy of Pediatrics.

  19. Multi-resolution statistical image reconstruction for mitigation of truncation effects: application to cone-beam CT of the head

    NASA Astrophysics Data System (ADS)

    Dang, Hao; Webster Stayman, J.; Sisniega, Alejandro; Zbijewski, Wojciech; Xu, Jennifer; Wang, Xiaohui; Foos, David H.; Aygun, Nafi; Koliatsos, Vassilis E.; Siewerdsen, Jeffrey H.

    2017-01-01

    A prototype cone-beam CT (CBCT) head scanner featuring model-based iterative reconstruction (MBIR) has been recently developed and demonstrated the potential for reliable detection of acute intracranial hemorrhage (ICH), which is vital to diagnosis of traumatic brain injury and hemorrhagic stroke. However, data truncation (e.g. due to the head holder) can result in artifacts that reduce image uniformity and challenge ICH detection. We propose a multi-resolution MBIR method with an extended reconstruction field of view (RFOV) to mitigate truncation effects in CBCT of the head. The image volume includes a fine voxel size in the (inner) nontruncated region and a coarse voxel size in the (outer) truncated region. This multi-resolution scheme allows extension of the RFOV to mitigate truncation effects while introducing minimal increase in computational complexity. The multi-resolution method was incorporated in a penalized weighted least-squares (PWLS) reconstruction framework previously developed for CBCT of the head. Experiments involving an anthropomorphic head phantom with truncation due to a carbon-fiber holder were shown to result in severe artifacts in conventional single-resolution PWLS, whereas extending the RFOV within the multi-resolution framework strongly reduced truncation artifacts. For the same extended RFOV, the multi-resolution approach reduced computation time compared to the single-resolution approach (viz. time reduced by 40.7%, 83.0%, and over 95% for an image volume of 6003, 8003, 10003 voxels). Algorithm parameters (e.g. regularization strength, the ratio of the fine and coarse voxel size, and RFOV size) were investigated to guide reliable parameter selection. The findings provide a promising method for truncation artifact reduction in CBCT and may be useful for other MBIR methods and applications for which truncation is a challenge.

  20. Raman scattering spectroscopy for explosives identification

    NASA Astrophysics Data System (ADS)

    Nagli, L.; Gaft, M.

    2007-04-01

    Real time detection and identification of explosives at a standoff distance is a major issue in efforts to develop defense against so-called Improvised Explosive Devices (IED). It is recognized that the only technique, which is potentially capable to standoff detection of minimal amounts of explosives is laser-based spectroscopy. LDS technique belongs to trace detection, namely to its micro-particles variety. We applied gated Raman and time-resolved luminescence spectroscopy for detection of main explosive materials, both factory and homemade. Raman system was developed and tested by LDS for field remote detection and identification of minimal amounts of explosives on relevant surfaces at a distance of up to 30 meters.

  1. Assessing Reliability of Medical Record Reviews for the Detection of Hospital Adverse Events.

    PubMed

    Ock, Minsu; Lee, Sang-il; Jo, Min-Woo; Lee, Jin Yong; Kim, Seon-Ha

    2015-09-01

    The purpose of this study was to assess the inter-rater reliability and intra-rater reliability of medical record review for the detection of hospital adverse events. We conducted two stages retrospective medical records review of a random sample of 96 patients from one acute-care general hospital. The first stage was an explicit patient record review by two nurses to detect the presence of 41 screening criteria (SC). The second stage was an implicit structured review by two physicians to identify the occurrence of adverse events from the positive cases on the SC. The inter-rater reliability of two nurses and that of two physicians were assessed. The intra-rater reliability was also evaluated by using test-retest method at approximately two weeks later. In 84.2% of the patient medical records, the nurses agreed as to the necessity for the second stage review (kappa, 0.68; 95% confidence interval [CI], 0.54 to 0.83). In 93.0% of the patient medical records screened by nurses, the physicians agreed about the absence or presence of adverse events (kappa, 0.71; 95% CI, 0.44 to 0.97). When assessing intra-rater reliability, the kappa indices of two nurses were 0.54 (95% CI, 0.31 to 0.77) and 0.67 (95% CI, 0.47 to 0.87), whereas those of two physicians were 0.87 (95% CI, 0.62 to 1.00) and 0.37 (95% CI, -0.16 to 0.89). In this study, the medical record review for detecting adverse events showed intermediate to good level of inter-rater and intra-rater reliability. Well organized training program for reviewers and clearly defining SC are required to get more reliable results in the hospital adverse event study.

  2. Network reliability maximization for stochastic-flow network subject to correlated failures using genetic algorithm and tabu\\xA0search

    NASA Astrophysics Data System (ADS)

    Yeh, Cheng-Ta; Lin, Yi-Kuei; Yang, Jo-Yun

    2018-07-01

    Network reliability is an important performance index for many real-life systems, such as electric power systems, computer systems and transportation systems. These systems can be modelled as stochastic-flow networks (SFNs) composed of arcs and nodes. Most system supervisors respect the network reliability maximization by finding the optimal multi-state resource assignment, which is one resource to each arc. However, a disaster may cause correlated failures for the assigned resources, affecting the network reliability. This article focuses on determining the optimal resource assignment with maximal network reliability for SFNs. To solve the problem, this study proposes a hybrid algorithm integrating the genetic algorithm and tabu search to determine the optimal assignment, called the hybrid GA-TS algorithm (HGTA), and integrates minimal paths, recursive sum of disjoint products and the correlated binomial distribution to calculate network reliability. Several practical numerical experiments are adopted to demonstrate that HGTA has better computational quality than several popular soft computing algorithms.

  3. Multi-hop routing mechanism for reliable sensor computing.

    PubMed

    Chen, Jiann-Liang; Ma, Yi-Wei; Lai, Chia-Ping; Hu, Chia-Cheng; Huang, Yueh-Min

    2009-01-01

    Current research on routing in wireless sensor computing concentrates on increasing the service lifetime, enabling scalability for large number of sensors and supporting fault tolerance for battery exhaustion and broken nodes. A sensor node is naturally exposed to various sources of unreliable communication channels and node failures. Sensor nodes have many failure modes, and each failure degrades the network performance. This work develops a novel mechanism, called Reliable Routing Mechanism (RRM), based on a hybrid cluster-based routing protocol to specify the best reliable routing path for sensor computing. Table-driven intra-cluster routing and on-demand inter-cluster routing are combined by changing the relationship between clusters for sensor computing. Applying a reliable routing mechanism in sensor computing can improve routing reliability, maintain low packet loss, minimize management overhead and save energy consumption. Simulation results indicate that the reliability of the proposed RRM mechanism is around 25% higher than that of the Dynamic Source Routing (DSR) and ad hoc On-demand Distance Vector routing (AODV) mechanisms.

  4. 48 CFR 242.7501 - Policy.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... DEFENSE CONTRACT MANAGEMENT CONTRACT ADMINISTRATION AND AUDIT SERVICES Contractor Accounting Systems and..., shall maintain an accounting system and related internal controls throughout contract performance which... accounting system and cost data are reliable; (c) Risk of misallocations and mischarges are minimized; and (d...

  5. Nanoimmunoassay to Detect Responses in Head and Neck Cancer: Feasibility in a Mouse Model.

    PubMed

    Hubbard, Matthew A; Khalil, Ashraf A; Schoeff, Stephen S; Allak, Amir; VanKoevering, Kyle K; Maxwell, Anne K; Adejumo, Oluwayemisi; Mendez, Rolando E; Jameson, Mark J

    2014-07-01

    To demonstrate the feasibility of detecting and quantifying extracellular signal-related kinase (ERK) phosphorylation status using nanoimmunoassay (NIA). Analyses using Cal27, SCC25, and OSC19 head and neck squamous carcinoma cell lines in vitro and in a murine xenograft model. NIA and immunoblot were performed on whole-cell lysates, tumor lysates, and fine-needle aspirate biopsies to detect ERK phosphorylation states. Using NIA, all 6 isoforms of ERK1/2, including nonphosphorylated, monophosphorylated, and diphosphorylated species, could be reliably detected, distinguished, and quantified in a single assay using a single antibody. In vitro treatment of Cal27 cells with the epidermal growth factor receptor inhibitor gefitinib abolished phospho-ERK detection by immunoblot but resulted in residual detectable species by NIA. Residual phospho-ERK in gefitinib-treated cells could be further reduced by the addition of the insulin-like growth factor 1 receptor inhibitor OSI-906; this correlated with an additional decrease in proliferation over gefitinib alone. In a pilot study of 4 murine xenograft tumors, NIA performed on tumor lysates and fine-needle aspirate biopsies demonstrated altered ERK profiles after 2 days of gefitinib treatment compared with untreated mice. NIA offers a novel approach to quantitating the activation state of signaling molecules such as ERK in nanoscale in vitro and in vivo samples across a wide dynamic range. As such, it has potential to provide molecular diagnostic information before, during, and after treatment using a minimally invasive technique. Further study is warranted to determine its utility in assessing signaling proteins as biomolecular outcome predictors in clinical trials. © American Academy of Otolaryngology—Head and Neck Surgery Foundation 2014.

  6. A consensus definition and rating scale for minimalist shoes.

    PubMed

    Esculier, Jean-Francois; Dubois, Blaise; Dionne, Clermont E; Leblond, Jean; Roy, Jean-Sébastien

    2015-01-01

    While minimalist running shoes may have an influence on running biomechanics and on the incidence of overuse injuries, the term "minimalist" is currently used without standardisation. The objectives of this study were to reach a consensus on a standard definition of minimalist running shoes, and to develop and validate a rating scale that could be used to determine the degree of minimalism of running shoes, the Minimalist Index (MI). For this modified Delphi study, 42 experts from 11 countries completed four electronic questionnaires on an optimal definition of minimalist shoes and on elements to include within the MI. Once MI was developed following consensus, 85 participants subjectively ranked randomly assigned footwear models from the most to the least minimalist and rated their degree of minimalism using visual analog scales (VAS), before evaluating the same footwear models using MI. A subsample of thirty participants reassessed the same shoes on another occasion. Construct validity and inter- and intra-rater reliability (intraclass correlation coefficients [ICC]; Gwet's AC1) of MI were evaluated. The following definition of minimalist shoes was agreed upon by 95 % of participants: "Footwear providing minimal interference with the natural movement of the foot due to its high flexibility, low heel to toe drop, weight and stack height, and the absence of motion control and stability devices". Characteristics to be included in MI were weight, flexibility, heel to toe drop, stack height and motion control/stability devices, each subscale carrying equal weighing (20 %) on final score. Total MI score was highly correlated with VAS (r = 0.91). A significant rank effect (p < 0.001) confirmed the MI's discriminative validity. Excellent intra- and inter-rater reliability was found for total MI score (ICC = 0.84-0.99) and for weight, stack height, heel to toe drop and flexibility subscales (AC1 = 0.82-0.99), while good inter-rater reliability was found for technologies (AC1 = 0.73). This standardised definition of minimalist shoes developed by an international panel of experts will improve future research on minimalist shoes and clinical recommendations. MI's adequate validity and reliability will allow distinguishing running shoes based on their degree of minimalism, and may help to decrease injuries related to footwear transition.

  7. Reliability, Safety and Error Recovery for Advanced Control Software

    NASA Technical Reports Server (NTRS)

    Malin, Jane T.

    2003-01-01

    For long-duration automated operation of regenerative life support systems in space environments, there is a need for advanced integration and control systems that are significantly more reliable and safe, and that support error recovery and minimization of operational failures. This presentation outlines some challenges of hazardous space environments and complex system interactions that can lead to system accidents. It discusses approaches to hazard analysis and error recovery for control software and challenges of supporting effective intervention by safety software and the crew.

  8. U.S. Geological Survey Virginia and West Virginia Water Science Center

    USGS Publications Warehouse

    Jastram, John D.

    2017-08-22

    The U.S. Geological Survey (USGS) serves the Nation by providing reliable scientific information to describe and understand the Earth; minimize loss of life and property from natural disasters; manage water, biological, energy, and mineral resources; and enhance and protect our quality of life. In support of this mission, the USGS Virginia and West Virginia Water Science Center works in cooperation with many entities to provide reliable, impartial scientific information to resource managers, planners, and the public.

  9. Electromyographic decoding of response to command in disorders of consciousness.

    PubMed

    Lesenfants, Damien; Habbal, Dina; Chatelle, Camille; Schnakers, Caroline; Laureys, Steven; Noirhomme, Quentin

    2016-11-15

    To propose a new methodology based on single-trial analysis for detecting residual response to command with EMG in patients with disorders of consciousness (DOC), overcoming the issue of trial dependency and decreasing the influence of a patient's fluctuation of vigilance or arousal over time on diagnostic accuracy. Forty-five patients with DOC (18 with vegetative/unresponsive wakefulness syndrome [VS/UWS], 22 in a minimally conscious state [MCS], 3 who emerged from MCS [EMCS], and 2 with locked-in syndrome [LIS]) and 20 healthy controls were included in the study. Patients were randomly instructed to either move their left or right hand or listen to a control command ("It is a sunny day") while EMG activity was recorded on both arms. Differential EMG activity was detected in all MCS cases displaying reproducible response to command at bedside on multiple assessments, even though only 6 of the 14 individuals presented a behavioral response to command on the day of the EMG assessment. An EMG response was also detected in all EMCS and LIS patients, and 2 MCS patients showing nonreflexive movements without command following at the bedside. None of the VS/UWS presented a response to command with this method. This method allowed us to reliably distinguish between different levels of consciousness and could potentially help decrease diagnostic errors in patients with motor impairment but presenting residual motor activity. © 2016 American Academy of Neurology.

  10. Multicolor microRNA FISH effectively differentiates tumor types

    PubMed Central

    Renwick, Neil; Cekan, Pavol; Masry, Paul A.; McGeary, Sean E.; Miller, Jason B.; Hafner, Markus; Li, Zhen; Mihailovic, Aleksandra; Morozov, Pavel; Brown, Miguel; Gogakos, Tasos; Mobin, Mehrpouya B.; Snorrason, Einar L.; Feilotter, Harriet E.; Zhang, Xiao; Perlis, Clifford S.; Wu, Hong; Suárez-Fariñas, Mayte; Feng, Huichen; Shuda, Masahiro; Moore, Patrick S.; Tron, Victor A.; Chang, Yuan; Tuschl, Thomas

    2013-01-01

    MicroRNAs (miRNAs) are excellent tumor biomarkers because of their cell-type specificity and abundance. However, many miRNA detection methods, such as real-time PCR, obliterate valuable visuospatial information in tissue samples. To enable miRNA visualization in formalin-fixed paraffin-embedded (FFPE) tissues, we developed multicolor miRNA FISH. As a proof of concept, we used this method to differentiate two skin tumors, basal cell carcinoma (BCC) and Merkel cell carcinoma (MCC), with overlapping histologic features but distinct cellular origins. Using sequencing-based miRNA profiling and discriminant analysis, we identified the tumor-specific miRNAs miR-205 and miR-375 in BCC and MCC, respectively. We addressed three major shortcomings in miRNA FISH, identifying optimal conditions for miRNA fixation and ribosomal RNA (rRNA) retention using model compounds and high-pressure liquid chromatography (HPLC) analyses, enhancing signal amplification and detection by increasing probe-hapten linker lengths, and improving probe specificity using shortened probes with minimal rRNA sequence complementarity. We validated our method on 4 BCC and 12 MCC tumors. Amplified miR-205 and miR-375 signals were normalized against directly detectable reference rRNA signals. Tumors were classified using predefined cutoff values, and all were correctly identified in blinded analysis. Our study establishes a reliable miRNA FISH technique for parallel visualization of differentially expressed miRNAs in FFPE tumor tissues. PMID:23728175

  11. BEAMing and Droplet Digital PCR Analysis of Mutant IDH1 mRNA in Glioma Patient Serum and Cerebrospinal Fluid Extracellular Vesicles.

    PubMed

    Chen, Walter W; Balaj, Leonora; Liau, Linda M; Samuels, Michael L; Kotsopoulos, Steve K; Maguire, Casey A; Loguidice, Lori; Soto, Horacio; Garrett, Matthew; Zhu, Lin Dan; Sivaraman, Sarada; Chen, Clark; Wong, Eric T; Carter, Bob S; Hochberg, Fred H; Breakefield, Xandra O; Skog, Johan

    2013-07-23

    Development of biofluid-based molecular diagnostic tests for cancer is an important step towards tumor characterization and real-time monitoring in a minimally invasive fashion. Extracellular vesicles (EVs) are released from tumor cells into body fluids and can provide a powerful platform for tumor biomarkers because they carry tumor proteins and nucleic acids. Detecting rare point mutations in the background of wild-type sequences in biofluids such as blood and cerebrospinal fluid (CSF) remains a major challenge. Techniques such as BEAMing (beads, emulsion, amplification, magnetics) PCR and droplet digital PCR (ddPCR) are substantially more sensitive than many other assays for mutant sequence detection. Here, we describe a novel approach that combines biofluid EV RNA and BEAMing RT-PCR (EV-BEAMing), as well droplet digital PCR to interrogate mutations from glioma tumors. EVs from CSF of patients with glioma were shown to contain mutant IDH1 transcripts, and we were able to reliably detect and quantify mutant and wild-type IDH1 RNA transcripts in CSF of patients with gliomas. EV-BEAMing and EV-ddPCR represent a valuable new strategy for cancer diagnostics, which can be applied to a variety of biofluids and neoplasms.Molecular Therapy-Nucleic Acids (2013) 2, e109; doi:10.1038/mtna.2013.28; published online 23 July 2013.

  12. Reduction of the pace polarization artefact for capture detection applications by a tri-phasic stimulation pulse.

    PubMed

    Sutton, R; Fröhlig, G; de Voogt, W G; Goethals, M; Hintringer, F; Kennergren, C; Scanu, P; Guilleman, D; Treese, N; Hartung, W M; Stammwitz, E; Muetstege, A

    2004-11-01

    This study investigated the ability to minimize pace polarization artefacts (PPA) by adjusting the post-stimulus pulse duration of a tri-phasic stimulation pulse. Adjustment of the stimulation pulse was enabled by downloading special study software into an already implanted pacemaker. Tests were performed in a total of 296 atrial leads and 311 ventricular leads. Both chronic and acute leads were included in the study. Statistically significant differences were found in the initial PPA (without any adjustment of the stimulus pulse) between atrial and ventricular leads. In addition, significant differences were observed among various lead models with respect to changes over time in the initial ventricular PPA. Successful PPA reduction was defined as a reduction of the PPA below 0.5 mV for atrial leads and below 1 mV for ventricular leads. Results show a success rate for ventricular and atrial PPA reduction of 97.8% and 98.7%, respectively. Threshold tests showed that after reduction of the PPA loss of ventricular capture can be reliably detected. However, atrial threshold tests showed many false positive evoked response detections. In addition, unexpectedly high evoked response amplitudes were observed in the atrium after reduction of the PPA. Results from additional measurements suggest that these high atrial evoked response amplitudes come from the influence of the input filter of the pacemaker.

  13. Characterization and detection of Vero cells infected with Herpes Simplex Virus type 1 using Raman spectroscopy and advanced statistical methods.

    PubMed

    Salman, A; Shufan, E; Zeiri, L; Huleihel, M

    2014-07-01

    Herpes viruses are involved in a variety of human disorders. Herpes Simplex Virus type 1 (HSV-1) is the most common among the herpes viruses and is primarily involved in human cutaneous disorders. Although the symptoms of infection by this virus are usually minimal, in some cases HSV-1 might cause serious infections in the eyes and the brain leading to blindness and even death. A drug, acyclovir, is available to counter this virus. The drug is most effective when used during the early stages of the infection, which makes early detection and identification of these viral infections highly important for successful treatment. In the present study we evaluated the potential of Raman spectroscopy as a sensitive, rapid, and reliable method for the detection and identification of HSV-1 viral infections in cell cultures. Using Raman spectroscopy followed by advanced statistical methods enabled us, with sensitivity approaching 100%, to differentiate between a control group of Vero cells and another group of Vero cells that had been infected with HSV-1. Cell sites that were "rich in membrane" gave the best results in the differentiation between the two categories. The major changes were observed in the 1195-1726 cm(-1) range of the Raman spectrum. The features in this range are attributed mainly to proteins, lipids, and nucleic acids. Copyright © 2014. Published by Elsevier Inc.

  14. Global multi-sensor satellite monitoring of volcanic SO2 and ash emissions in support to aviation control

    NASA Astrophysics Data System (ADS)

    Brenot, H.; Theys, N.; van Gent, J.; Van Roozendael, M.; van der A, R.; Clarisse, L.; Hurtmans, D.; Ngadi, Y.; Coheur, P.-F.; Clerbaux, C.

    2012-04-01

    The "Support to Aviation Control Service" (SACS; http://sacs.aeronomie.be) is an ESA-funded project hosted by the Belgian Institute for Space Aeronomy. The service provides near real-time (NRT) global SO2 and volcanic ash data, as well as alerts in case of volcanic eruptions. The SACS service is primarily designed to support the Volcanic Ash Advisory Centers (VAACs) in their mandate to gather information on volcanic clouds and give advice to airline and air traffic control organisations. SACS also serves other users that subscribe to the service, in particular local volcano observatories and research scientists. SACS is based on the combined use of UV-visible (SCIAMACHY, OMI, GOME-2) and infrared (AIRS, IASI) satellite instruments. When a volcanic eruption is detected, SACS issues an alert that takes the form of a notification sent by e-mail to users. This notification points to a dedicated web page where all relevant information is available and can be visualized with user-friendly tools. The strength of a multi-sensor approach relies in the use of satellite data with different overpasses times, minimizing the time-lag for detection and enhancing the reliability of such alerts. This paper will give a general presentation of the SACS service, different techniques used to detect volcanic plumes. It will also highlight the strengths and limitations of the service and measurements.

  15. Portable 4.6 Micrometers Laser Absorption Spectrometer for Carbon Monoxide Monitoring and Fire Detection

    NASA Technical Reports Server (NTRS)

    Briggs, Ryan M.; Frez, Clifford; Forouhar, Siamak; May, Randy D.; Ruff, Gary A.

    2013-01-01

    The air quality aboard manned spacecraft must be continuously monitored to ensure crew safety and identify equipment malfunctions. In particular, accurate real-time monitoring of carbon monoxide (CO) levels helps to prevent chronic exposure and can also provide early detection of combustion-related hazards. For long-duration missions, environmental monitoring grows in importance, but the mass and volume of monitoring instruments must be minimized. Furthermore, environmental analysis beyond low-Earth orbit must be performed in-situ, as sample return becomes impractical. Due to their small size, low power draw, and performance reliability, semiconductor-laser-based absorption spectrometers are viable candidates for this purpose. To reduce instrument form factor and complexity, the emission wavelength of the laser source should coincide with strong fundamental absorption lines of the target gases, which occur in the 3 to 5 micrometers wavelength range for most combustion products of interest, thereby reducing the absorption path length required for low-level concentration measurements. To address the needs of current and future NASA missions, we have developed a prototype absorption spectrometer using a semiconductor quantum cascade laser source operating near 4.6 micrometers that can be used to detect low concentrations of CO with a compact single-pass absorption cell. In this study, we present the design of the prototype instrument and report on measurements of CO emissions from the combustion of a variety of aerospace plastics.

  16. The Automated Assessment of Postural Stability: Balance Detection Algorithm.

    PubMed

    Napoli, Alessandro; Glass, Stephen M; Tucker, Carole; Obeid, Iyad

    2017-12-01

    Impaired balance is a common indicator of mild traumatic brain injury, concussion and musculoskeletal injury. Given the clinical relevance of such injuries, especially in military settings, it is paramount to develop more accurate and reliable on-field evaluation tools. This work presents the design and implementation of the automated assessment of postural stability (AAPS) system, for on-field evaluations following concussion. The AAPS is a computer system, based on inexpensive off-the-shelf components and custom software, that aims to automatically and reliably evaluate balance deficits, by replicating a known on-field clinical test, namely, the Balance Error Scoring System (BESS). The AAPS main innovation is its balance error detection algorithm that has been designed to acquire data from a Microsoft Kinect ® sensor and convert them into clinically-relevant BESS scores, using the same detection criteria defined by the original BESS test. In order to assess the AAPS balance evaluation capability, a total of 15 healthy subjects (7 male, 8 female) were required to perform the BESS test, while simultaneously being tracked by a Kinect 2.0 sensor and a professional-grade motion capture system (Qualisys AB, Gothenburg, Sweden). High definition videos with BESS trials were scored off-line by three experienced observers for reference scores. AAPS performance was assessed by comparing the AAPS automated scores to those derived by three experienced observers. Our results show that the AAPS error detection algorithm presented here can accurately and precisely detect balance deficits with performance levels that are comparable to those of experienced medical personnel. Specifically, agreement levels between the AAPS algorithm and the human average BESS scores ranging between 87.9% (single-leg on foam) and 99.8% (double-leg on firm ground) were detected. Moreover, statistically significant differences in balance scores were not detected by an ANOVA test with alpha equal to 0.05. Despite some level of disagreement between human and AAPS-generated scores, the use of an automated system yields important advantages over currently available human-based alternatives. These results underscore the value of using the AAPS, that can be quickly deployed in the field and/or in outdoor settings with minimal set-up time. Finally, the AAPS can record multiple error types and their time course with extremely high temporal resolution. These features are not achievable by humans, who cannot keep track of multiple balance errors with such a high resolution. Together, these results suggest that computerized BESS calculation may provide more accurate and consistent measures of balance than those derived from human experts.

  17. Psychometric and Clinimetric Properties of the Melbourne Assessment 2 in Children With Cerebral Palsy.

    PubMed

    Wang, Tien-Ni; Liang, Kai-Jie; Liu, Yi-Chia; Shieh, Jeng-Yi; Chen, Hao-Ling

    2017-09-01

    To examine the psychometric and clinimetric properties of the Melbourne Assessment 2 (MA2), an outcome measurement that is increasingly used in clinical studies. Psychometric and clinimetric study. Community. Seventeen children with cerebral palsy (CP) from 5 to 12 years were recruited for the estimation of the test-retest reliability and minimal detectable change (MDC). Thirty-five children with CP were recruited to receive an 8-week intensive neurorehabilitation intervention to estimate the validity, responsiveness, and minimal clinically important difference (MCID). Thirty-five children with CP received upper limb neurorehabilitation programs for 8 weeks. The MA2 and the criterion measures, including the Bruininks-Oseretsky Test of Motor Proficiency, 2nd edition (BOT-2), the Box and Blocks Test (BBT), and the Pediatric Motor Activity Log-Revised (PMAL-R), were evaluated at pretreatment and posttreatment. The MA2 has 4 subscales: range of motion, fluency, accuracy, and dexterity. The test-retest reliability of the MA2 is high (intraclass correlation coefficient, .92-.98). The significant relationships between the MA2 and BBT, BOT-2, and PMAL-R support its validity. The significance of paired t test results (P<.001) and large magnitudes of the standardized response mean (1.70-2.00) confirm the responsiveness of the MA2. The MDC values of the 4 subscales of the MA2 are 2.85, 1.63, 1.97, and 1.84, respectively, and the suggested MCID values of these 4 subscales are 2.35, 3.20, 2.09, and 2.22, respectively, indicating the minimum scores of improvement to be interpreted as both statistically significant and clinically important. The study findings indicate that the MA2 has sound psychometric and clinimetric properties and is thus an adequate measurement for research and clinical applications. Copyright © 2017 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  18. The patellofemoral pain and osteoarthritis subscale of the KOOS (KOOS-PF): development and validation using the COSMIN checklist.

    PubMed

    Crossley, Kay M; Macri, Erin M; Cowan, Sallie M; Collins, Natalie J; Roos, Ewa M

    2017-03-03

    Patellofemoral pain and osteoarthritis are prevalent and associated with substantial pain and functional impairments. Patient-reported outcome measures (PROMs) are recommended for research and clinical use, but no PROMs are specific for patellofemoral osteoarthritis, and existing PROMs for patellofemoral pain have methodological limitations. This study aimed to develop a new subscale of the Knee injury and Osteoarthritis Outcome Score for patellofemoral pain and osteoarthritis (KOOS-PF), and evaluate its measurement properties. Items were generated using input from 50 patients with patellofemoral pain and/or osteoarthritis and 14 health and medical clinicians. Item reduction was performed using data from patellofemoral cohorts (n=138). We used the COnsesus-based Standards for the selection of health Measurements INstruments guidelines to evaluate reliability, validity, responsiveness and interpretability of the final version of KOOS-PF and other KOOS subscales. From an initial 80 generated items, the final subscale included 11 items. KOOS-PF items loaded predominantly on one factor, pain during activities that load the patellofemoral joint. KOOS-PF had good internal consistency (Cronbach's α 0.86) and adequate test-retest reliability (intraclass correlation coefficient 0.86). Hypothesis testing supported convergent, divergent and known-groups validity. Responsiveness was confirmed, with KOOS-PF demonstrating a moderate correlation with Global Rating of Change scores (r 0.52) and large effect size (Cohen's d 0.89). Minimal detectable change was 2.3 (groups) and 16 (individuals), while minimal important change was 16.4. There were no floor or ceiling effects. The 11-item KOOS-PF, developed in consultation with patients and clinicians, demonstrated adequate measurement properties, and is recommended for clinical and research use in patients with patellofemoral pain and osteoarthritis. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  19. Longitudinal psychometric attributes, responsiveness, and importance of change: An approach using the SCOPA-Psychosocial questionnaire.

    PubMed

    Martínez-Martin, Pablo; Carod-Artal, Francisco Javier; da Silveira Ribeiro, Luciola; Ziomkowski, Sofia; Vargas, Antonio Pedro; Kummer, Wladimir; Mesquita, Hudson Mourão

    2008-08-15

    The objective of this study was to illustrate the analysis of longitudinal validity, responsiveness, and importance of change, using the SCOPA-Psychosocial Questionnaire (SCOPA-PS) as a source of empirical data. Sixty-seven patients with PD in Hoehn and Yahr (HY) stage 2 were followed up for 1 year and assessed by means of the Schwab and England Scale, Unified PD Rating Scale (UPDRS), Hospital Anxiety and Depression Scale (HADS), PDQ-39, and SCOPA-PS. A range of methods was applied to enable each of the target attributes to be analyzed from different conceptual stances. The SCOPA-PS displayed satisfactory acceptability (no floor or ceiling effect), internal consistency (alpha = 0.80-0.84), convergent validity (r(S) = 0.70-0.82 with PDQ-39), and precision (SEM = 8.80), both at baseline and at the end of follow-up. The threshold value for significant change ranged from 17.25 (1.96 SEM) to 24.39 (Smallest real difference and Reliable change index). Threshold values for a clinically meaningful change were 0.73-1.26 (effect size, standardized response mean, responsiveness statistic). Change in SCOPA-PS scores correlated strongly with change in total UPDRS, HADS, and PDQ-39 scores, and reliably detected 70% of cases that worsened according to the PDQ-39. The minimally important change (MIC) for "minimally impaired" patients as per the PDQ39 was 8.30-9.10 points. Indices such as 1.96 SEM, effect size, and correlation with the change in other measures provide useful information about different concepts of responsiveness. The MIC should be determined for each specific setting, using distribution- and anchor-based methods. The SCOPA-PS showed satisfactory longitudinal attributes and responsiveness in stage-2 Brazilian patients with PD across 1 year of follow-up. (c) 2008 Movement Disorder Society.

  20. Robust penalty method for structural synthesis

    NASA Technical Reports Server (NTRS)

    Kamat, M. P.

    1983-01-01

    The Sequential Unconstrained Minimization Technique (SUMT) offers an easy way of solving nonlinearly constrained problems. However, this algorithm frequently suffers from the need to minimize an ill-conditioned penalty function. An ill-conditioned minimization problem can be solved very effectively by posing the problem as one of integrating a system of stiff differential equations utilizing concepts from singular perturbation theory. This paper evaluates the robustness and the reliability of such a singular perturbation based SUMT algorithm on two different problems of structural optimization of widely separated scales. The report concludes that whereas conventional SUMT can be bogged down by frequent ill-conditioning, especially in large scale problems, the singular perturbation SUMT has no such difficulty in converging to very accurate solutions.

  1. The Development of DNA Based Methods for the Reliable and Efficient Identification of Nicotiana tabacum in Tobacco and Its Derived Products

    PubMed Central

    Fan, Wei; Li, Rong; Li, Sifan; Ping, Wenli; Li, Shujun; Naumova, Alexandra; Peelen, Tamara; Yuan, Zheng; Zhang, Dabing

    2016-01-01

    Reliable methods are needed to detect the presence of tobacco components in tobacco products to effectively control smuggling and classify tariff and excise in tobacco industry to control illegal tobacco trade. In this study, two sensitive and specific DNA based methods, one quantitative real-time PCR (qPCR) assay and the other loop-mediated isothermal amplification (LAMP) assay, were developed for the reliable and efficient detection of the presence of tobacco (Nicotiana tabacum) in various tobacco samples and commodities. Both assays targeted the same sequence of the uridine 5′-monophosphate synthase (UMPS), and their specificities and sensitivities were determined with various plant materials. Both qPCR and LAMP methods were reliable and accurate in the rapid detection of tobacco components in various practical samples, including customs samples, reconstituted tobacco samples, and locally purchased cigarettes, showing high potential for their application in tobacco identification, particularly in the special cases where the morphology or chemical compositions of tobacco have been disrupted. Therefore, combining both methods would facilitate not only the detection of tobacco smuggling control, but also the detection of tariff classification and of excise. PMID:27635142

  2. Apollo experience report: Detection and minimization of ignition hazards from water/glycol contamination of silver-clad electrical circuitry

    NASA Technical Reports Server (NTRS)

    Downs, W. R.

    1976-01-01

    The potential flammability hazard when a water/glycol solution contacts defectively insulated silver-clad copper circuitry or electrical components carrying a direct current is described. The chemical reactions and means for detecting them are explained. Methods for detecting and cleaning contaminated areas and the use of inhibitors to arrest chemical reactivity are also explained. Preventive measures to minimize hazards are given. Photomicrographs of the chemical reactions occurring on silver clad wires are also included.

  3. Reliability of recordings of subgingival calculus detected using an ultrasonic device.

    PubMed

    Corraini, Priscila; López, Rodrigo

    2015-04-01

    To assess the intra-examiner reliability of recordings of subgingival calculus detected using an ultrasonic device, and to investigate the influence of subject-, tooth- and site-level factors on the reliability of these subgingival calculus recordings. On two occasions, within a 1-week interval, 147 adult periodontitis patients received a full-mouth clinical periodontal examination by a single trained examiner. Duplicate subgingival calculus recordings, in six sites per tooth, were obtained using an ultrasonic device for calculus detection and removal. Agreement was observed in 65 % of the 22,584 duplicate subgingival calculus recordings, ranging 45 % to 83 % according to subject. Using hierarchical modeling, disagreements in the subgingival calculus duplicate recordings were more likely in all other sites than the mid-buccal, and in sites harboring supragingival calculus. Disagreements were less likely in sites with PD ≥  4 mm and with furcation involvement  ≥  degree 2. Bleeding on probing or suppuration did not influence the reliability of subgingival calculus. At the subject-level, disagreements were less likely in patients presenting with the highest and lowest extent categories of the covariate subgingival calculus. The reliability of subgingival calculus recordings using the ultrasound technology is reasonable. The results of the present study suggest that the reliability of subgingival calculus recordings is not influenced by the presence of inflammation. Moreover, subgingival calculus can be more reliably detected using the ultrasound device at sites with higher need for periodontal therapy, i.e., sites presenting with deep pockets and premolars and molars with furcation involvement.

  4. Ring-like reliable PON planning with physical constraints for a smart grid

    NASA Astrophysics Data System (ADS)

    Wang, Xin; Gu, Rentao; Ji, Yuefeng

    2016-01-01

    Due to the high reliability requirements in the communication networks of a smart grid, a ring-like reliable PON is an ideal choice to carry power distribution information. Economical network planning is also very important for the smart grid communication infrastructure. Although the ring-like reliable PON has been widely used in the real applications, as far as we know, little research has been done on the network optimization subject of the ring-like reliable PON. Most PON planning research studies only consider a star-like topology or cascaded PON network, which barely guarantees the reliability requirements of the smart grid. In this paper, we mainly investigate the economical network planning problem for the ring-like reliable PON of the smart grid. To address this issue, we built a mathematical model for the planning problem of the ring-like reliable PON, and the objective was to minimize the total deployment costs under physical constraints. The model is simplified such that all of the nodes have the same properties, except OLT, because each potential splitter site can be located in the same ONU position in power communication networks. The simplified model is used to construct an optimal main tree topology in the complete graph and a backup-protected tree topology in the residual graph. An efficient heuristic algorithm, called the Constraints and Minimal Weight Oriented Fast Searching Algorithm (CMW-FSA), is proposed. In CMW-FSA, a feasible solution can be obtained directly with oriented constraints and a few recursive search processes. From the simulation results, the proposed planning model and CMW-FSA are verified to be accurate (the error rates are less than 0.4%) and effective compared with the accurate solution (CAESA), especially in small and sparse scenarios. The CMW-FSA significantly reduces the computation time compared with the CAESA. The time complexity algorithm of the CMW-FSA is acceptable and calculated as T(n) = O(n3). After evaluating the effects of the parameters of the two PON systems, the total planning costs of each scenario show a general declining trend and reach a threshold as the respective maximal transmission distances and maximal time delays increase.

  5. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Colotelo, Alison HA; Smokorowski, Karen; Haxton, Tim

    Current methods of fish epithelial injury detection are limited to gross macroscopic examination that has a subjective bias as well as an inability to reliably quantify the degree of injury. Fluorescein, a presumptive test for blood, has been shown to have the capability to detect and quantify fish epithelial injury. However, there are several other presumptive tests for blood (Bluestar*, phenolphthalein, and HemastixH) that may have benefits over the use of fluorescein, particularly for field research on wild fish. This study investigated the capabilities of these four tests to detect and quantify a variety of injuries commonly encountered by fishmore » (abrasion, cuts, fin frays, and punctures) using the freshwater bluegill Lepomis macrochirus as a model. Fluorescein was consistently found to be the most reliable (i.e., detected the highest proportion of true positive results and rarely detected false positive reactions) of the four presumptive tests for blood compared. Further testing was conducted to examine the reliability of fluorescein. By 24 h after an injury was inflicted, the injury was no longer detectable by fluorescein, and when fluorescein was applied to an injured fish, the fluorescein was no longer detectable 3 h after application. In a comparison of two common anaesthetics used in fisheries research, there was no significant difference in the proportion of injury detected when 3- aminobenzoic acid ethyl ester methanesulfate (tricaine) was used compared with a clove oil and ethanol (1:9) solution. In summary, fluorescein was the most reliable presumptive test for blood examined in this study for the detection and quantification of recent (hours) fish epithelial injury.« less

  6. Reproducibility: Reliability and agreement of short version of Western Ontario Rotator Cuff Index (Short-WORC) in patients with rotator cuff disorders.

    PubMed

    Dewan, Neha; MacDermid, Joy C; MacIntyre, Norma; Grewal, Ruby

    2016-01-01

    Recently, a shorter version of Western Ontario Rotator Cuff Index (Short-WORC) was proposed as a subset of 7 items from the original 21-item WORC. However, the reproducibility of the Short-WORC has not been established. To determine reproducibility (reliability and agreement) of the Short-WORC among patients with rotator cuff disorders (RCDs). Patients (n = 153) diagnosed with RCD completed the WORC at baseline and at 3 months post-operatively (n = 146). The Short-WORC was extracted from the full version of WORC. From this retrospective cohort, 43 patients were retested within 5 weeks, if they remained stable. Cronbach's alpha (α) and intra class correlation coefficients (ICC2,1) were used to assess internal consistency and test-retest reliability respectively. Standard error measurement (SEM), minimal detectable change (MDC90) and Bland Altman (BA) plots were used to assess agreement. No floor and ceiling effects were reported for either the Short-WORC or WORC. Cronbach's α were 0.84 and 0.90 at baseline and 0.89 and 0.95 at 3 month of follow up for Short-WORC and WORC respectively. The ICC2,1 were 0.89 and 0.91 for the Short-WORC and WORC respectively. The agreement parameters for the Short-WORC were: SEMagreement = 8.8, MDC90individual = 20.3, MDC90group = 5.1. We found substantial agreement between the two versions of WORC on BA plots with minimal (mean difference (d) <1) systematic differences between them. The limits of agreement (LOA) between two versions of WORC were similar across sessions and fell within range of -11.7 to 13.2 points at test and -14.7 to 14.7 points at retest. Short-WORC and WORC demonstrates strong reproducibility and can be used for group and individual comparison of health-related quality of life (HRQoL) among patients with RCD. Wider LOA may be expected when using the Short-WORC for individual patient assessment. Reproducibility data is essential, but should be supplemented by validation of actual Short-WORC with samples representing the spectrum of RCD. N/A. Copyright © 2016 Hanley & Belfus. Published by Elsevier Inc. All rights reserved.

  7. Robust, Radiation Tolerant Command and Data Handling and Power System Electronics from NASA Goddard Space Flight Center

    NASA Technical Reports Server (NTRS)

    Nguyen, Hanson C.; Fraction, James; Ortiz-Acosta, Melyane; Dakermanji, George; Kercheval, Bradford P.; Hernandez-Pellerano, Amri; Kim, David S.; Jung, David S.; Meyer, Steven E.; Mallik, Udayan; hide

    2016-01-01

    The Goddard Modular Smallsat Architecture (GMSA) is developed at NASA Goddard Space Flight Center (GSFC) to address future reliability along with minimizing cost and schedule challenges for NASA Cubesat and Smallsat missions.

  8. Green Synthesis of Nanomaterials: Environmental Aspects

    EPA Science Inventory

    There is always a search for reliable and environmentally friendly processes to manufacture metal and metal oxide nanoparticles minimizing or even eliminating the use of hazardous chemicals. The only way to develop these “green” processes is to adapt benign synthesis approaches t...

  9. 28 CFR 22.1 - Purpose.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Administration DEPARTMENT OF JUSTICE CONFIDENTIALITY OF IDENTIFIABLE RESEARCH AND STATISTICAL INFORMATION § 22.1... information identifiable to a private person obtained in a research or statistical program may only be used... reliability of federally-supported research and statistical findings by minimizing subject concern over...

  10. 28 CFR 22.1 - Purpose.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Administration DEPARTMENT OF JUSTICE CONFIDENTIALITY OF IDENTIFIABLE RESEARCH AND STATISTICAL INFORMATION § 22.1... information identifiable to a private person obtained in a research or statistical program may only be used... reliability of federally-supported research and statistical findings by minimizing subject concern over...

  11. Geo-Referenced Dynamic Pushbroom Stereo Mosaics for 3D and Moving Target Extraction - A New Geometric Approach

    DTIC Science & Technology

    2009-12-01

    facilitating reliable stereo matching, occlusion handling, accurate 3D reconstruction and robust moving target detection . We use the fact that all the...a moving platform, we will have to naturally and effectively handle obvious motion parallax and object occlusions in order to be able to detect ...facilitating reliable stereo matching, occlusion handling, accurate 3D reconstruction and robust moving target detection . Based on the above two

  12. UV gated Raman spectroscopy for standoff detection of explosives

    NASA Astrophysics Data System (ADS)

    Gaft, M.; Nagli, L.

    2008-07-01

    Real-time detection and identification of explosives at a standoff distance is a major issue in efforts to develop defense against so-called improvised explosive devices (IED). It is recognized that the only method, which is potentially capable to standoff detection of minimal amounts of explosives is laser-based spectroscopy. LDS technique belongs to trace detection, namely to its micro-particles variety. It is based on commonly held belief that surface contamination was very difficult to avoid and could be exploited for standoff detection. We have applied gated Raman spectroscopy for detection of main explosive materials, both factory and homemade. We developed and tested a Raman system for the field remote detection and identification of minimal amounts of explosives on relevant surfaces at a distance of up to 30 m.

  13. Differentiated protection method in passive optical networks based on OPEX

    NASA Astrophysics Data System (ADS)

    Zhang, Zhicheng; Guo, Wei; Jin, Yaohui; Sun, Weiqiang; Hu, Weisheng

    2011-12-01

    Reliable service delivery becomes more significant due to increased dependency on electronic services all over society and the growing importance of reliable service delivery. As the capability of PON increasing, both residential and business customers may be included in a PON. Meanwhile, OPEX have been proven to be a very important factor of the total cost for a telecommunication operator. Thus, in this paper, we present the partial protection PON architecture and compare the operational expenditures (OPEX) of fully duplicated protection and partly duplicated protection for ONUs with different distributed fiber length, reliability requirement and penalty cost per hour. At last, we propose a differentiated protection method to minimize OPEX.

  14. Solar-cell interconnect design for terrestrial photovoltaic modules

    NASA Technical Reports Server (NTRS)

    Mon, G. R.; Moore, D. M.; Ross, R. G., Jr.

    1984-01-01

    Useful solar cell interconnect reliability design and life prediction algorithms are presented, together with experimental data indicating that the classical strain cycle (fatigue) curve for the interconnect material does not account for the statistical scatter that is required in reliability predictions. This shortcoming is presently addressed by fitting a functional form to experimental cumulative interconnect failure rate data, which thereby yields statistical fatigue curves enabling not only the prediction of cumulative interconnect failures during the design life of an array field, but also the quantitative interpretation of data from accelerated thermal cycling tests. Optimal interconnect cost reliability design algorithms are also derived which may allow the minimization of energy cost over the design life of the array field.

  15. Coexistence of enhanced mobile broadband communications and ultra-reliable low-latency communications in mobile front-haul

    NASA Astrophysics Data System (ADS)

    Ying, Kai; Kowalski, John M.; Nogami, Toshizo; Yin, Zhanping; Sheng, Jia

    2018-01-01

    5G systems are supposed to support coexistence of multiple services such as ultra reliable low latency communications (URLLC) and enhanced mobile broadband (eMBB) communications. The target of eMBB communications is to meet the high-throughput requirement while URLLC are used for some high priority services. Due to the sporadic nature and low latency requirement, URLLC transmission may pre-empt the resource of eMBB transmission. Our work is to analyze the URLLC impact on eMBB transmission in mobile front-haul. Then, some solutions are proposed to guarantee the reliability/latency requirements for URLLC services and minimize the impact to eMBB services at the same time.

  16. Solar-cell interconnect design for terrestrial photovoltaic modules

    NASA Astrophysics Data System (ADS)

    Mon, G. R.; Moore, D. M.; Ross, R. G., Jr.

    1984-11-01

    Useful solar cell interconnect reliability design and life prediction algorithms are presented, together with experimental data indicating that the classical strain cycle (fatigue) curve for the interconnect material does not account for the statistical scatter that is required in reliability predictions. This shortcoming is presently addressed by fitting a functional form to experimental cumulative interconnect failure rate data, which thereby yields statistical fatigue curves enabling not only the prediction of cumulative interconnect failures during the design life of an array field, but also the quantitative interpretation of data from accelerated thermal cycling tests. Optimal interconnect cost reliability design algorithms are also derived which may allow the minimization of energy cost over the design life of the array field.

  17. A cost assessment of reliability requirements for shuttle-recoverable experiments

    NASA Technical Reports Server (NTRS)

    Campbell, J. W.

    1975-01-01

    The relaunching of unsuccessful experiments or satellites will become a real option with the advent of the space shuttle. An examination was made of the cost effectiveness of relaxing reliability requirements for experiment hardware by allowing more than one flight of an experiment in the event of its failure. Any desired overall reliability or probability of mission success can be acquired by launching an experiment with less reliability two or more times if necessary. Although this procedure leads to uncertainty in total cost projections, because the number of flights is not known in advance, a considerable cost reduction can sometimes be achieved. In cases where reflight costs are low relative to the experiment's cost, three flights with overall reliability 0.9 can be made for less than half the cost of one flight with a reliability of 0.9. An example typical of shuttle payload cost projections is cited where three low reliability flights would cost less than $50 million and a single high reliability flight would cost over $100 million. The ratio of reflight cost to experiment cost is varied and its effect on the range in total cost is observed. An optimum design reliability selection criterion to minimize expected cost is proposed, and a simple graphical method of determining this reliability is demonstrated.

  18. Statistical Tests of Reliability of NDE

    NASA Technical Reports Server (NTRS)

    Baaklini, George Y.; Klima, Stanley J.; Roth, Don J.; Kiser, James D.

    1987-01-01

    Capabilities of advanced material-testing techniques analyzed. Collection of four reports illustrates statistical method for characterizing flaw-detecting capabilities of sophisticated nondestructive evaluation (NDE). Method used to determine reliability of several state-of-the-art NDE techniques for detecting failure-causing flaws in advanced ceramic materials considered for use in automobiles, airplanes, and space vehicles.

  19. Reliability of the dynavision™ d2 for assessing reaction time performance.

    PubMed

    Wells, Adam J; Hoffman, Jay R; Beyer, Kyle S; Jajtner, Adam R; Gonzalez, Adam M; Townsend, Jeremy R; Mangine, Gerald T; Robinson, Edward H; McCormack, William P; Fragala, Maren S; Stout, Jeffrey R

    2014-01-01

    Recently, the Dynavision™ D2 Visuomotor Training Device (D2) has emerged as a tool in the assessment of reaction time (RT); however, information regarding the reliability of the D2 have been limited, and to date, reliability data have been limited to non- generalizable samples. Therefore, the purpose of this study was to establish intraclass correlation coefficients (ICC2,1) for the D2 that are generalizable across a population of recreationally active young adults. Forty-two recreationally active men and women (age: 23.41 ± 4.84 years; height: 1.72 ± 0.11 m; mass: 76.62 ± 18.26 Kg) completed 6 trials for three RT tasks of increasing complexity. Each trial was separated by at least 48-hours. A repeated measures ANOVA was used to detect differences in performance across the six trials. Intraclass correlation coefficients (ICC2,1) standard error of measurement (SEM), and minimal differences (MD) were used to determine the reliability of the D2 from the two sessions with the least significant difference score. Moderate to strong reliability was demonstrated for visual RT (ICC2,1: 0.84, SEM: 0.033), and reactive ability in both Mode A and Mode B tasks (Mode A hits: ICC2,1: 0.75, SEM: 5.44; Mode B hits: ICC2,1: 0.73, SEM: 8.57). Motor RT (ICC2,1: 0.63, SEM: 0.035s) showed fair reliability, while average RT per hit for Modes A and B showed moderate reliability (ICC2,1: 0.68, SEM: 0.43 s and ICC2,1: 0.72, SEM: 0.03 s respectively). It appears that one familiarization trial is necessary for the choice reaction time (CRT) task while three familiarization trials are necessary for reactive RT tasks. In conclusion, results indicate that the Dynavision™ D2 is a reliable device to assess neuromuscular reactivity given that an adequate practice is provided. The data presented are generalizable to a population of recreationally active young adults. Key PointsThe Dynavision™ D2 is a light-training reaction device, developed to train sensory motor integration through the visual system, offering the ability to assess visual and motor reaction to both central and peripheral stimuli, with a capacity to integrate increasing levels of cognitive challenge.The Dynavision™ D2 is a reliable instrument for assessing reaction time in recreationally active young adults.It is recommended that one familiarization trial is necessary for the choice reaction time task assessment to learn the test protocol, while three familiarization trials are needed for reactive ability in Mode A and Mode B before a subsequent reliable baseline score can be established.Significant training effects were observed for all reaction time tests and should be taken into account with continuous trials.

  20. Applicability of the ReproQ client experiences questionnaire for quality improvement in maternity care

    PubMed Central

    Scheerhagen, Marisja; Tholhuijsen, Dominique J.C.; Birnie, Erwin; Franx, Arie; Bonsel, Gouke J.

    2016-01-01

    Background. The ReproQuestionnaire (ReproQ) measures the client’s experience with maternity care, following the WHO responsiveness model. In 2015, the ReproQ was appointed as national client experience questionnaire and will be added to the national list of indicators in maternity care. For using the ReproQ in quality improvement, the questionnaire should be able to identify best and worst practices. To achieve this, ReproQ should be reliable and able to identify relevant differences. Methods and Findings. We sent questionnaires to 17,867 women six weeks after labor (response 32%). Additionally, we invited 915 women for the retest (response 29%). Next we determined the test–retest reliability, the Minimally Important Difference (MID) and six known group comparisons, using two scorings methods: the percentage women with at least one negative experience and the mean score. The reliability for the percentage negative experience and mean score was both ‘good’ (Absolute agreement = 79%; intraclass correlation coefficient = 0.78). The MID was 11% for the percentage negative and 0.15 for the mean score. Application of the MIDs revealed relevant differences in women’s experience with regard to professional continuity, setting continuity and having travel time. Conclusions. The measurement characteristics of the ReproQ support its use in quality improvement cycle. Test–retest reliability was good, and the observed minimal important difference allows for discrimination of good and poor performers, also at the level of specific features of performance. PMID:27478690

Top