Sample records for reliability small size

  1. A reliability evaluation methodology for memory chips for space applications when sample size is small

    NASA Technical Reports Server (NTRS)

    Chen, Y.; Nguyen, D.; Guertin, S.; Berstein, J.; White, M.; Menke, R.; Kayali, S.

    2003-01-01

    This paper presents a reliability evaluation methodology to obtain the statistical reliability information of memory chips for space applications when the test sample size needs to be kept small because of the high cost of the radiation hardness memories.

  2. Study samples are too small to produce sufficiently precise reliability coefficients.

    PubMed

    Charter, Richard A

    2003-04-01

    In a survey of journal articles, test manuals, and test critique books, the author found that a mean sample size (N) of 260 participants had been used for reliability studies on 742 tests. The distribution was skewed because the median sample size for the total sample was only 90. The median sample sizes for the internal consistency, retest, and interjudge reliabilities were 182, 64, and 36, respectively. The author presented sample size statistics for the various internal consistency methods and types of tests. In general, the author found that the sample sizes that were used in the internal consistency studies were too small to produce sufficiently precise reliability coefficients, which in turn could cause imprecise estimates of examinee true-score confidence intervals. The results also suggest that larger sample sizes have been used in the last decade compared with those that were used in earlier decades.

  3. A Note on Structural Equation Modeling Estimates of Reliability

    ERIC Educational Resources Information Center

    Yang, Yanyun; Green, Samuel B.

    2010-01-01

    Reliability can be estimated using structural equation modeling (SEM). Two potential problems with this approach are that estimates may be unstable with small sample sizes and biased with misspecified models. A Monte Carlo study was conducted to investigate the quality of SEM estimates of reliability by themselves and relative to coefficient…

  4. Mid-level perceptual features distinguish objects of different real-world sizes.

    PubMed

    Long, Bria; Konkle, Talia; Cohen, Michael A; Alvarez, George A

    2016-01-01

    Understanding how perceptual and conceptual representations are connected is a fundamental goal of cognitive science. Here, we focus on a broad conceptual distinction that constrains how we interact with objects--real-world size. Although there appear to be clear perceptual correlates for basic-level categories (apples look like other apples, oranges look like other oranges), the perceptual correlates of broader categorical distinctions are largely unexplored, i.e., do small objects look like other small objects? Because there are many kinds of small objects (e.g., cups, keys), there may be no reliable perceptual features that distinguish them from big objects (e.g., cars, tables). Contrary to this intuition, we demonstrated that big and small objects have reliable perceptual differences that can be extracted by early stages of visual processing. In a series of visual search studies, participants found target objects faster when the distractor objects differed in real-world size. These results held when we broadly sampled big and small objects, when we controlled for low-level features and image statistics, and when we reduced objects to texforms--unrecognizable textures that loosely preserve an object's form. However, this effect was absent when we used more basic textures. These results demonstrate that big and small objects have reliably different mid-level perceptual features, and suggest that early perceptual information about broad-category membership may influence downstream object perception, recognition, and categorization processes. (c) 2015 APA, all rights reserved).

  5. Statistical issues in reporting quality data: small samples and casemix variation.

    PubMed

    Zaslavsky, A M

    2001-12-01

    To present two key statistical issues that arise in analysis and reporting of quality data. Casemix variation is relevant to quality reporting when the units being measured have differing distributions of patient characteristics that also affect the quality outcome. When this is the case, adjustment using stratification or regression may be appropriate. Such adjustments may be controversial when the patient characteristic does not have an obvious relationship to the outcome. Stratified reporting poses problems for sample size and reporting format, but may be useful when casemix effects vary across units. Although there are no absolute standards of reliability, high reliabilities (interunit F > or = 10 or reliability > or = 0.9) are desirable for distinguishing above- and below-average units. When small or unequal sample sizes complicate reporting, precision may be improved using indirect estimation techniques that incorporate auxiliary information, and 'shrinkage' estimation can help to summarize the strength of evidence about units with small samples. With broader understanding of casemix adjustment and methods for analyzing small samples, quality data can be analysed and reported more accurately.

  6. Simulation analyses of space use: Home range estimates, variability, and sample size

    USGS Publications Warehouse

    Bekoff, Marc; Mech, L. David

    1984-01-01

    Simulations of space use by animals were run to determine the relationship among home range area estimates, variability, and sample size (number of locations). As sample size increased, home range size increased asymptotically, whereas variability decreased among mean home range area estimates generated by multiple simulations for the same sample size. Our results suggest that field workers should ascertain between 100 and 200 locations in order to estimate reliably home range area. In some cases, this suggested guideline is higher than values found in the few published studies in which the relationship between home range area and number of locations is addressed. Sampling differences for small species occupying relatively small home ranges indicate that fewer locations may be sufficient to allow for a reliable estimate of home range. Intraspecific variability in social status (group member, loner, resident, transient), age, sex, reproductive condition, and food resources also have to be considered, as do season, habitat, and differences in sampling and analytical methods. Comparative data still are needed.

  7. Using small area estimation and Lidar-derived variables for multivariate prediction of forest attributes

    Treesearch

    F. Mauro; Vicente Monleon; H. Temesgen

    2015-01-01

    Small area estimation (SAE) techniques have been successfully applied in forest inventories to provide reliable estimates for domains where the sample size is small (i.e. small areas). Previous studies have explored the use of either Area Level or Unit Level Empirical Best Linear Unbiased Predictors (EBLUPs) in a univariate framework, modeling each variable of interest...

  8. Extrapolating Single Organic Ion Solvation Thermochemistry from Simulated Water Nanodroplets.

    PubMed

    Coles, Jonathan P; Houriez, Céline; Meot-Ner Mautner, Michael; Masella, Michel

    2016-09-08

    We compute the ion/water interaction energies of methylated ammonium cations and alkylated carboxylate anions solvated in large nanodroplets of 10 000 water molecules using 10 ns molecular dynamics simulations and an all-atom polarizable force-field approach. Together with our earlier results concerning the solvation of these organic ions in nanodroplets whose molecular sizes range from 50 to 1000, these new data allow us to discuss the reliability of extrapolating absolute single-ion bulk solvation energies from small ion/water droplets using common power-law functions of cluster size. We show that reliable estimates of these energies can be extrapolated from a small data set comprising the results of three droplets whose sizes are between 100 and 1000 using a basic power-law function of droplet size. This agrees with an earlier conclusion drawn from a model built within the mean spherical framework and paves the road toward a theoretical protocol to systematically compute the solvation energies of complex organic ions.

  9. Small numbers, disclosure risk, security, and reliability issues in Web-based data query systems.

    PubMed

    Rudolph, Barbara A; Shah, Gulzar H; Love, Denise

    2006-01-01

    This article describes the process for developing consensus guidelines and tools for releasing public health data via the Web and highlights approaches leading agencies have taken to balance disclosure risk with public dissemination of reliable health statistics. An agency's choice of statistical methods for improving the reliability of released data for Web-based query systems is based upon a number of factors, including query system design (dynamic analysis vs preaggregated data and tables), population size, cell size, data use, and how data will be supplied to users. The article also describes those efforts that are necessary to reduce the risk of disclosure of an individual's protected health information.

  10. Questionnaire-based assessment of executive functioning: Psychometrics.

    PubMed

    Castellanos, Irina; Kronenberger, William G; Pisoni, David B

    2018-01-01

    The psychometric properties of the Learning, Executive, and Attention Functioning (LEAF) scale were investigated in an outpatient clinical pediatric sample. As a part of clinical testing, the LEAF scale, which broadly measures neuropsychological abilities related to executive functioning and learning, was administered to parents of 118 children and adolescents referred for psychological testing at a pediatric psychology clinic; 85 teachers also completed LEAF scales to assess reliability across different raters and settings. Scores on neuropsychological tests of executive functioning and academic achievement were abstracted from charts. Psychometric analyses of the LEAF scale demonstrated satisfactory internal consistency, parent-teacher inter-rater reliability in the small to large effect size range, and test-retest reliability in the large effect size range, similar to values for other executive functioning checklists. Correlations between corresponding subscales on the LEAF and other behavior checklists were large, while most correlations with neuropsychological tests of executive functioning and achievement were significant but in the small to medium range. Results support the utility of the LEAF as a reliable and valid questionnaire-based assessment of delays and disturbances in executive functioning and learning. Applications and advantages of the LEAF and other questionnaire measures of executive functioning in clinical neuropsychology settings are discussed.

  11. Particle size analysis of sediments, soils and related particulate materials for forensic purposes using laser granulometry.

    PubMed

    Pye, Kenneth; Blott, Simon J

    2004-08-11

    Particle size is a fundamental property of any sediment, soil or dust deposit which can provide important clues to nature and provenance. For forensic work, the particle size distribution of sometimes very small samples requires precise determination using a rapid and reliable method with a high resolution. The Coulter trade mark LS230 laser granulometer offers rapid and accurate sizing of particles in the range 0.04-2000 microm for a variety of sample types, including soils, unconsolidated sediments, dusts, powders and other particulate materials. Reliable results are possible for sample weights of just 50 mg. Discrimination between samples is performed on the basis of the shape of the particle size curves and statistical measures of the size distributions. In routine forensic work laser granulometry data can rarely be used in isolation and should be considered in combination with results from other techniques to reach an overall conclusion.

  12. Small-Scale System for Evaluation of Stretch-Flangeability with Excellent Reliability

    NASA Astrophysics Data System (ADS)

    Yoon, Jae Ik; Jung, Jaimyun; Lee, Hak Hyeon; Kim, Hyoung Seop

    2018-02-01

    We propose a system for evaluating the stretch-flangeability of small-scale specimens based on the hole-expansion ratio (HER). The system has no size effect and shows excellent reproducibility, reliability, and economic efficiency. To verify the reliability and reproducibility of the proposed hole-expansion testing (HET) method, the deformation behavior of the conventional standard stretch-flangeability evaluation method was compared with the proposed method using finite-element method simulations. The distribution of shearing defects in the hole-edge region of the specimen, which has a significant influence on the HER, was investigated using scanning electron microscopy. The stretch-flangeability of several kinds of advanced high-strength steel determined using the conventional standard method was compared with that using the proposed small-scale HET method. It was verified that the deformation behavior, morphology and distribution of shearing defects, and stretch-flangeability results for the specimens were the same for the conventional standard method and the proposed small-scale stretch-flangeability evaluation system.

  13. Small-Scale System for Evaluation of Stretch-Flangeability with Excellent Reliability

    NASA Astrophysics Data System (ADS)

    Yoon, Jae Ik; Jung, Jaimyun; Lee, Hak Hyeon; Kim, Hyoung Seop

    2018-06-01

    We propose a system for evaluating the stretch-flangeability of small-scale specimens based on the hole-expansion ratio (HER). The system has no size effect and shows excellent reproducibility, reliability, and economic efficiency. To verify the reliability and reproducibility of the proposed hole-expansion testing (HET) method, the deformation behavior of the conventional standard stretch-flangeability evaluation method was compared with the proposed method using finite-element method simulations. The distribution of shearing defects in the hole-edge region of the specimen, which has a significant influence on the HER, was investigated using scanning electron microscopy. The stretch-flangeability of several kinds of advanced high-strength steel determined using the conventional standard method was compared with that using the proposed small-scale HET method. It was verified that the deformation behavior, morphology and distribution of shearing defects, and stretch-flangeability results for the specimens were the same for the conventional standard method and the proposed small-scale stretch-flangeability evaluation system.

  14. Size matters: bigger is faster.

    PubMed

    Sereno, Sara C; O'Donnell, Patrick J; Sereno, Margaret E

    2009-06-01

    A largely unexplored aspect of lexical access in visual word recognition is "semantic size"--namely, the real-world size of an object to which a word refers. A total of 42 participants performed a lexical decision task on concrete nouns denoting either big or small objects (e.g., bookcase or teaspoon). Items were matched pairwise on relevant lexical dimensions. Participants' reaction times were reliably faster to semantically "big" versus "small" words. The results are discussed in terms of possible mechanisms, including more active representations for "big" words, due to the ecological importance attributed to large objects in the environment and the relative speed of neural responses to large objects.

  15. Evaluation of the local homogeneity fluctuation of sinter of the small chip size MLCCs by means of mid-infrared spectroscopy

    NASA Astrophysics Data System (ADS)

    Tsuzuku, Koichiro; Hagiwara, Tomoya; Takeoka, Shunsuke; Ikemoto, Yuka

    2008-05-01

    Vibration bands of dielectric ceramics appear at a mid-infrared (MIR) and those position and shape are changed owing to change environment of crystal lattice. Therefore, micro-focus MIR spectroscopy is a one of useful tool to evaluate very small size capacitor (e.g. smaller than 0.5 mm in chip size). Very small size multi-layer capacitor: MLCC are one of very important device to produce high quality electrical products such as cell phone, etc. Quality and reliability of MLCC are corresponding to not only average dielectric properties but also local fluctuation of them. Furthermore, local fluctuation of dielectric properties of MLCC could evaluate with MIR spectroscopy. It is possible to obtain a satisfied MIR spectrum from small size samples performed by a micro-focus spectrometer combined with synchrotron radiation as a high luminance light source at beam line BL43IR of SPring-8. From the above result, it is possible to evaluate the degree of homogeneity by comparing the shape change of Ti-O peak on IR spectra.

  16. Validation of a New Metric for Assessing the Integration of Health Protection and Health Promotion in a Sample of Small- and Medium-Sized Employer Groups.

    PubMed

    Williams, Jessica A R; Nelson, Candace C; Cabán-Martinez, Alberto J; Katz, Jeffrey N; Wagner, Gregory R; Pronk, Nicolaas P; Sorensen, Glorian; McLellan, Deborah L

    2015-09-01

    To conduct validation analyses for a new measure of the integration of worksite health protection and health promotion approaches developed in earlier research. A survey of small- to medium-sized employers located in the United States was conducted between October 2013 and March 2014 (n = 111). Cronbach α coefficient was used to assess reliability, and Pearson correlation coefficients were used to assess convergent validity. The integration score was positively associated with the measures of occupational safety and health and health promotion activities/policies-supporting its convergent validity (Pearson correlation coefficients of 0.32 to 0.47). Cronbach α coefficient was 0.94, indicating excellent reliability. The integration score seems to be a promising tool for assessing integration of health promotion and health protection. Further work is needed to test its dimensionality and validate its use in other samples.

  17. High correlations between MRI brain volume measurements based on NeuroQuant® and FreeSurfer.

    PubMed

    Ross, David E; Ochs, Alfred L; Tate, David F; Tokac, Umit; Seabaugh, John; Abildskov, Tracy J; Bigler, Erin D

    2018-05-30

    NeuroQuant ® (NQ) and FreeSurfer (FS) are commonly used computer-automated programs for measuring MRI brain volume. Previously they were reported to have high intermethod reliabilities but often large intermethod effect size differences. We hypothesized that linear transformations could be used to reduce the large effect sizes. This study was an extension of our previously reported study. We performed NQ and FS brain volume measurements on 60 subjects (including normal controls, patients with traumatic brain injury, and patients with Alzheimer's disease). We used two statistical approaches in parallel to develop methods for transforming FS volumes into NQ volumes: traditional linear regression, and Bayesian linear regression. For both methods, we used regression analyses to develop linear transformations of the FS volumes to make them more similar to the NQ volumes. The FS-to-NQ transformations based on traditional linear regression resulted in effect sizes which were small to moderate. The transformations based on Bayesian linear regression resulted in all effect sizes being trivially small. To our knowledge, this is the first report describing a method for transforming FS to NQ data so as to achieve high reliability and low effect size differences. Machine learning methods like Bayesian regression may be more useful than traditional methods. Copyright © 2018 Elsevier B.V. All rights reserved.

  18. Multisite Reliability of Cognitive BOLD Data

    PubMed Central

    Brown, Gregory G.; Mathalon, Daniel H.; Stern, Hal; Ford, Judith; Mueller, Bryon; Greve, Douglas N.; McCarthy, Gregory; Voyvodic, Jim; Glover, Gary; Diaz, Michele; Yetter, Elizabeth; Burak Ozyurt, I.; Jorgensen, Kasper W.; Wible, Cynthia G.; Turner, Jessica A.; Thompson, Wesley K.; Potkin, Steven G.

    2010-01-01

    Investigators perform multi-site functional magnetic resonance imaging studies to increase statistical power, to enhance generalizability, and to improve the likelihood of sampling relevant subgroups. Yet undesired site variation in imaging methods could off-set these potential advantages. We used variance components analysis to investigate sources of variation in the blood oxygen level dependent (BOLD) signal across four 3T magnets in voxelwise and region of interest (ROI) analyses. Eighteen participants traveled to four magnet sites to complete eight runs of a working memory task involving emotional or neutral distraction. Person variance was more than 10 times larger than site variance for five of six ROIs studied. Person-by-site interactions, however, contributed sizable unwanted variance to the total. Averaging over runs increased between-site reliability, with many voxels showing good to excellent between-site reliability when eight runs were averaged and regions of interest showing fair to good reliability. Between-site reliability depended on the specific functional contrast analyzed in addition to the number of runs averaged. Although median effect size was correlated with between-site reliability, dissociations were observed for many voxels. Brain regions where the pooled effect size was large but between-site reliability was poor were associated with reduced individual differences. Brain regions where the pooled effect size was small but between-site reliability was excellent were associated with a balance of participants who displayed consistently positive or consistently negative BOLD responses. Although between-site reliability of BOLD data can be good to excellent, acquiring highly reliable data requires robust activation paradigms, ongoing quality assurance, and careful experimental control. PMID:20932915

  19. Binomial outcomes in dataset with some clusters of size two: can the dependence of twins be accounted for? A simulation study comparing the reliability of statistical methods based on a dataset of preterm infants.

    PubMed

    Sauzet, Odile; Peacock, Janet L

    2017-07-20

    The analysis of perinatal outcomes often involves datasets with some multiple births. These are datasets mostly formed of independent observations and a limited number of clusters of size two (twins) and maybe of size three or more. This non-independence needs to be accounted for in the statistical analysis. Using simulated data based on a dataset of preterm infants we have previously investigated the performance of several approaches to the analysis of continuous outcomes in the presence of some clusters of size two. Mixed models have been developed for binomial outcomes but very little is known about their reliability when only a limited number of small clusters are present. Using simulated data based on a dataset of preterm infants we investigated the performance of several approaches to the analysis of binomial outcomes in the presence of some clusters of size two. Logistic models, several methods of estimation for the logistic random intercept models and generalised estimating equations were compared. The presence of even a small percentage of twins means that a logistic regression model will underestimate all parameters but a logistic random intercept model fails to estimate the correlation between siblings if the percentage of twins is too small and will provide similar estimates to logistic regression. The method which seems to provide the best balance between estimation of the standard error and the parameter for any percentage of twins is the generalised estimating equations. This study has shown that the number of covariates or the level two variance do not necessarily affect the performance of the various methods used to analyse datasets containing twins but when the percentage of small clusters is too small, mixed models cannot capture the dependence between siblings.

  20. View of Pakistan Atomic Energy Commission towards SMPR's in the light of KANUPP performance

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Huseini, S.D.

    1985-01-01

    The developing countries in general do not have grid capacities adequate enough to incorporate standard size, economic but rather large nuclear power plants for maximum advantage. Therefore, small and medium size reactors (SMPR) have been and still are, of particular interest to the developing countries in spite of certain known problems with these reactors. Pakistan Atomic Energy Commission (PAEC) has been operating a CANDU type of a small PHWR plant since 1971 when it was connected to the local Karachi grid. This paper describes PAEC's view in the light of KANUPP performance with respect to such factors associated with SMPR'smore » as selection of suitable reactor size and type, its operation in a grid of small capacity, flexibility of operation and its role as a reliable source of electrical power.« less

  1. Improving the Cost Efficiency and Readiness of MC-130 Aircrew Training: A Case Study

    DTIC Science & Technology

    2015-01-01

    51 Jiang, Changbing, "A reliable solver of Euclidean traveling salesman problems with Microsoft excel add-in tools for small-size systems...DisplayPage.aspx?DocType=Reference&ItemId=+++1 343364&Pubabbrev=JAWA 124 Jiang, Changbing, "A Reliable Solver of Euclidean Traveling Salesman Problems with...49 Figure 4.5 Training Resources Locations Traveling Salesperson Problem In order to participate in training, aircrews must fly to the

  2. Does fin coloration signal social status in a dominance hierarchy of the livebearing fish Xiphophorus variatus?

    PubMed

    Culumber, Zachary W; Monks, Scott

    2014-09-01

    In each population of the livebearing fish Xiphophorus variatus, only a small portion of the adult males develop bright yellow-red (YR) coloration on the dorsal and caudal fins. Here we characterized the dominance hierarchy in X. variatus and tested whether YR coloration is related to a male's position in the hierarchy and can therefore serve as a reliable cue to rival males. Populations varied considerably in the frequency of YR males. Across all populations, males with YR coloration were significantly larger than the rest of the males in the population. Observations of aggressive interactions among males in small groups in the laboratory revealed a sized-based dominance hierarchy with YR males at the top. Aggression was more common among males of a similar size and fighting increased as male body size differences decreased. However, despite the reliability of YR coloration as a signal of dominance status, males at lower social ranks did not avoid aggression with YR males and YR males did not experience fewer aggressive attacks compared to non-YR males. Our findings demonstrate that fin coloration is a reliable cue of a male's social status but rival males appear to not use this information to avoid potentially costly interactions with dominant males, suggesting that YR fin coloration has not evolved as a cue in agonistic interactions. Copyright © 2014 Elsevier B.V. All rights reserved.

  3. Optimizing Probability of Detection Point Estimate Demonstration

    NASA Technical Reports Server (NTRS)

    Koshti, Ajay M.

    2017-01-01

    Probability of detection (POD) analysis is used in assessing reliably detectable flaw size in nondestructive evaluation (NDE). MIL-HDBK-18231and associated mh18232POD software gives most common methods of POD analysis. Real flaws such as cracks and crack-like flaws are desired to be detected using these NDE methods. A reliably detectable crack size is required for safe life analysis of fracture critical parts. The paper provides discussion on optimizing probability of detection (POD) demonstration experiments using Point Estimate Method. POD Point estimate method is used by NASA for qualifying special NDE procedures. The point estimate method uses binomial distribution for probability density. Normally, a set of 29 flaws of same size within some tolerance are used in the demonstration. The optimization is performed to provide acceptable value for probability of passing demonstration (PPD) and achieving acceptable value for probability of false (POF) calls while keeping the flaw sizes in the set as small as possible.

  4. Systematic review of the multidimensional fatigue symptom inventory-short form.

    PubMed

    Donovan, Kristine A; Stein, Kevin D; Lee, Morgan; Leach, Corinne R; Ilozumba, Onaedo; Jacobsen, Paul B

    2015-01-01

    Fatigue is a subjective complaint that is believed to be multifactorial in its etiology and multidimensional in its expression. Fatigue may be experienced by individuals in different dimensions as physical, mental, and emotional tiredness. The purposes of this study were to review and characterize the use of the 30-item Multidimensional Fatigue Symptom Inventory-Short Form (MFSI-SF) in published studies and to evaluate the available evidence for its psychometric properties. A systematic review was conducted to identify published articles reporting results for the MFSI-SF. Data were analyzed to characterize internal consistency reliability of multi-item MFSI-SF scales and test-retest reliability. Correlation coefficients were summarized to characterize concurrent, convergent, and divergent validity. Standardized effect sizes were calculated to characterize the discriminative validity of the MFSI-SF and its sensitivity to change. Seventy articles were identified. Sample sizes reported ranged from 10 to 529 and nearly half consisted exclusively of females. More than half the samples were composed of cancer patients; of those, 59% were breast cancer patients. Mean alpha coefficients for MFSI-SF fatigue subscales ranged from 0.84 for physical fatigue to 0.93 for general fatigue. The MFSI-SF demonstrated moderate test-retest reliability in a small number of studies. Correlations with other fatigue and vitality measures were moderate to large in size and in the expected direction. The MFSI-SF fatigue subscales were positively correlated with measures of distress, depressive, and anxious symptoms. Effect sizes for discriminative validity ranged from medium to large, while effect sizes for sensitivity to change ranged from small to large. Findings demonstrate the positive psychometric properties of the MFSI-SF, provide evidence for its usefulness in medically ill and nonmedically ill individuals, and support its use in future studies.

  5. Reproducibility of R-fMRI metrics on the impact of different strategies for multiple comparison correction and sample sizes.

    PubMed

    Chen, Xiao; Lu, Bin; Yan, Chao-Gan

    2018-01-01

    Concerns regarding reproducibility of resting-state functional magnetic resonance imaging (R-fMRI) findings have been raised. Little is known about how to operationally define R-fMRI reproducibility and to what extent it is affected by multiple comparison correction strategies and sample size. We comprehensively assessed two aspects of reproducibility, test-retest reliability and replicability, on widely used R-fMRI metrics in both between-subject contrasts of sex differences and within-subject comparisons of eyes-open and eyes-closed (EOEC) conditions. We noted permutation test with Threshold-Free Cluster Enhancement (TFCE), a strict multiple comparison correction strategy, reached the best balance between family-wise error rate (under 5%) and test-retest reliability/replicability (e.g., 0.68 for test-retest reliability and 0.25 for replicability of amplitude of low-frequency fluctuations (ALFF) for between-subject sex differences, 0.49 for replicability of ALFF for within-subject EOEC differences). Although R-fMRI indices attained moderate reliabilities, they replicated poorly in distinct datasets (replicability < 0.3 for between-subject sex differences, < 0.5 for within-subject EOEC differences). By randomly drawing different sample sizes from a single site, we found reliability, sensitivity and positive predictive value (PPV) rose as sample size increased. Small sample sizes (e.g., < 80 [40 per group]) not only minimized power (sensitivity < 2%), but also decreased the likelihood that significant results reflect "true" effects (PPV < 0.26) in sex differences. Our findings have implications for how to select multiple comparison correction strategies and highlight the importance of sufficiently large sample sizes in R-fMRI studies to enhance reproducibility. Hum Brain Mapp 39:300-318, 2018. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  6. Effect of Small Numbers of Test Results on Accuracy of Hoek-Brown Strength Parameter Estimations: A Statistical Simulation Study

    NASA Astrophysics Data System (ADS)

    Bozorgzadeh, Nezam; Yanagimura, Yoko; Harrison, John P.

    2017-12-01

    The Hoek-Brown empirical strength criterion for intact rock is widely used as the basis for estimating the strength of rock masses. Estimations of the intact rock H-B parameters, namely the empirical constant m and the uniaxial compressive strength σc, are commonly obtained by fitting the criterion to triaxial strength data sets of small sample size. This paper investigates how such small sample sizes affect the uncertainty associated with the H-B parameter estimations. We use Monte Carlo (MC) simulation to generate data sets of different sizes and different combinations of H-B parameters, and then investigate the uncertainty in H-B parameters estimated from these limited data sets. We show that the uncertainties depend not only on the level of variability but also on the particular combination of parameters being investigated. As particular combinations of H-B parameters can informally be considered to represent specific rock types, we discuss that as the minimum number of required samples depends on rock type it should correspond to some acceptable level of uncertainty in the estimations. Also, a comparison of the results from our analysis with actual rock strength data shows that the probability of obtaining reliable strength parameter estimations using small samples may be very low. We further discuss the impact of this on ongoing implementation of reliability-based design protocols and conclude with suggestions for improvements in this respect.

  7. Quantum-dot size and thin-film dielectric constant: precision measurement and disparity with simple models.

    PubMed

    Grinolds, Darcy D W; Brown, Patrick R; Harris, Daniel K; Bulovic, Vladimir; Bawendi, Moungi G

    2015-01-14

    We study the dielectric constant of lead sulfide quantum dot (QD) films as a function of the volume fraction of QDs by varying the QD size and keeping the ligand constant. We create a reliable QD sizing curve using small-angle X-ray scattering (SAXS), thin-film SAXS to extract a pair-distribution function for QD spacing, and a stacked-capacitor geometry to measure the capacitance of the thin film. Our data support a reduced dielectric constant in nanoparticles.

  8. The reliability and stability of visual working memory capacity.

    PubMed

    Xu, Z; Adam, K C S; Fang, X; Vogel, E K

    2018-04-01

    Because of the central role of working memory capacity in cognition, many studies have used short measures of working memory capacity to examine its relationship to other domains. Here, we measured the reliability and stability of visual working memory capacity, measured using a single-probe change detection task. In Experiment 1, the participants (N = 135) completed a large number of trials of a change detection task (540 in total, 180 each of set sizes 4, 6, and 8). With large numbers of both trials and participants, reliability estimates were high (α > .9). We then used an iterative down-sampling procedure to create a look-up table for expected reliability in experiments with small sample sizes. In Experiment 2, the participants (N = 79) completed 31 sessions of single-probe change detection. The first 30 sessions took place over 30 consecutive days, and the last session took place 30 days later. This unprecedented number of sessions allowed us to examine the effects of practice on stability and internal reliability. Even after much practice, individual differences were stable over time (average between-session r = .76).

  9. Solid Insulated Switchgear and Investigation of its Mechanical and Electrical Reliability

    NASA Astrophysics Data System (ADS)

    Sato, Junichi; Kinoshita, Susumu; Sakaguchi, Osamu; Miyagawa, Masaru; Shimizu, Toshio; Homma, Mitsutaka

    SF6 gas is applied widely to medium voltage switchgear because of its high insulation reliability and down-sizing ability. However, SF6 gas was placed on the list of greenhouse gases under the Kyoto Protocol in 1997. Since then, the investigation and development concerning SF6-free or less has carried out activity. Therefore, we paid attention to the solid material which has higher dielectric strength than SF6, and we have newly developed solid insulated switchgear (SIS) achieved by molding all main circuit. A new epoxy casting material is applied, which contains a great deal of spherical silica and a small amount of rubber particles. This new material has the high mechanical strength, high thermal resistance, high toughness, and also high dielectric strength because of directly molding the vacuum bottle, down-sizing and reliability. This paper describes about the technology of a new epoxy casting material which achieves the SIS. In addition, the mechanical and electrical reliability test of SIS applied a new epoxy resin are carried out, and effectiveness of the development material and the mechanical and electrical reliability of SIS are verified.

  10. Negative ion-driven associated particle neutron generator

    DOE PAGES

    Antolak, A. J.; Leung, K. N.; Morse, D. H.; ...

    2015-10-09

    We describe an associated particle neutron generator that employs a negative ion source to produce high neutron flux from a small source size. Furthermore, negative ions produced in an rf-driven plasma source are extracted through a small aperture to form a beam which bombards a positively biased, high voltage target electrode. Electrons co-extracted with the negative ions are removed by a permanent magnet electron filter. The use of negative ions enables high neutron output (100% atomic ion beam), high quality imaging (small neutron source size), and reliable operation (no high voltage breakdowns). Finally, the neutron generator can operate in eithermore » pulsed or continuous-wave (cw) mode and has been demonstrated to produce 10 6 D-D n/s (equivalent to similar to 10 8 D-T n/s) from a 1 mm-diameter neutron source size to facilitate high fidelity associated particle imaging.« less

  11. Annual design-based estimation for the annualized inventories of forest inventory and analysis: sample size determination

    Treesearch

    Hans T. Schreuder; Jin-Mann S. Lin; John Teply

    2000-01-01

    The Forest Inventory and Analysis units in the USDA Forest Service have been mandated by Congress to go to an annualized inventory where a certain percentage of plots, say 20 percent, will be measured in each State each year. Although this will result in an annual sample size that will be too small for reliable inference for many areas, it is a sufficiently large...

  12. Comparative analyses of basal rate of metabolism in mammals: data selection does matter.

    PubMed

    Genoud, Michel; Isler, Karin; Martin, Robert D

    2018-02-01

    Basal rate of metabolism (BMR) is a physiological parameter that should be measured under strictly defined experimental conditions. In comparative analyses among mammals BMR is widely used as an index of the intensity of the metabolic machinery or as a proxy for energy expenditure. Many databases with BMR values for mammals are available, but the criteria used to select metabolic data as BMR estimates have often varied and the potential effect of this variability has rarely been questioned. We provide a new, expanded BMR database reflecting compliance with standard criteria (resting, postabsorptive state; thermal neutrality; adult, non-reproductive status for females) and examine potential effects of differential selectivity on the results of comparative analyses. The database includes 1739 different entries for 817 species of mammals, compiled from the original sources. It provides information permitting assessment of the validity of each estimate and presents the value closest to a proper BMR for each entry. Using different selection criteria, several alternative data sets were extracted and used in comparative analyses of (i) the scaling of BMR to body mass and (ii) the relationship between brain mass and BMR. It was expected that results would be especially dependent on selection criteria with small sample sizes and with relatively weak relationships. Phylogenetically informed regression (phylogenetic generalized least squares, PGLS) was applied to the alternative data sets for several different clades (Mammalia, Eutheria, Metatheria, or individual orders). For Mammalia, a 'subsampling procedure' was also applied, in which random subsamples of different sample sizes were taken from each original data set and successively analysed. In each case, two data sets with identical sample size and species, but comprising BMR data with different degrees of reliability, were compared. Selection criteria had minor effects on scaling equations computed for large clades (Mammalia, Eutheria, Metatheria), although less-reliable estimates of BMR were generally about 12-20% larger than more-reliable ones. Larger effects were found with more-limited clades, such as sciuromorph rodents. For the relationship between BMR and brain mass the results of comparative analyses were found to depend strongly on the data set used, especially with more-limited, order-level clades. In fact, with small sample sizes (e.g. <100) results often appeared erratic. Subsampling revealed that sample size has a non-linear effect on the probability of a zero slope for a given relationship. Depending on the species included, results could differ dramatically, especially with small sample sizes. Overall, our findings indicate a need for due diligence when selecting BMR estimates and caution regarding results (even if seemingly significant) with small sample sizes. © 2017 Cambridge Philosophical Society.

  13. Localised estimates and spatial mapping of poverty incidence in the state of Bihar in India—An application of small area estimation techniques

    PubMed Central

    Aditya, Kaustav; Sud, U. C.

    2018-01-01

    Poverty affects many people, but the ramifications and impacts affect all aspects of society. Information about the incidence of poverty is therefore an important parameter of the population for policy analysis and decision making. In order to provide specific, targeted solutions when addressing poverty disadvantage small area statistics are needed. Surveys are typically designed and planned to produce reliable estimates of population characteristics of interest mainly at higher geographic area such as national and state level. Sample sizes are usually not large enough to provide reliable estimates for disaggregated analysis. In many instances estimates are required for areas of the population for which the survey providing the data was unplanned. Then, for areas with small sample sizes, direct survey estimation of population characteristics based only on the data available from the particular area tends to be unreliable. This paper describes an application of small area estimation (SAE) approach to improve the precision of estimates of poverty incidence at district level in the State of Bihar in India by linking data from the Household Consumer Expenditure Survey 2011–12 of NSSO and the Population Census 2011. The results show that the district level estimates generated by SAE method are more precise and representative. In contrast, the direct survey estimates based on survey data alone are less stable. PMID:29879202

  14. Localised estimates and spatial mapping of poverty incidence in the state of Bihar in India-An application of small area estimation techniques.

    PubMed

    Chandra, Hukum; Aditya, Kaustav; Sud, U C

    2018-01-01

    Poverty affects many people, but the ramifications and impacts affect all aspects of society. Information about the incidence of poverty is therefore an important parameter of the population for policy analysis and decision making. In order to provide specific, targeted solutions when addressing poverty disadvantage small area statistics are needed. Surveys are typically designed and planned to produce reliable estimates of population characteristics of interest mainly at higher geographic area such as national and state level. Sample sizes are usually not large enough to provide reliable estimates for disaggregated analysis. In many instances estimates are required for areas of the population for which the survey providing the data was unplanned. Then, for areas with small sample sizes, direct survey estimation of population characteristics based only on the data available from the particular area tends to be unreliable. This paper describes an application of small area estimation (SAE) approach to improve the precision of estimates of poverty incidence at district level in the State of Bihar in India by linking data from the Household Consumer Expenditure Survey 2011-12 of NSSO and the Population Census 2011. The results show that the district level estimates generated by SAE method are more precise and representative. In contrast, the direct survey estimates based on survey data alone are less stable.

  15. Application of dual-energy x-ray techniques for automated food container inspection

    NASA Astrophysics Data System (ADS)

    Shashishekhar, N.; Veselitza, D.

    2016-02-01

    Manufacturing for plastic food containers often results in small metal particles getting into the containers during the production process. Metal detectors are usually not sensitive enough to detect these metal particles (0.5 mm or lesser), especially when the containers are stacked in large sealed shipping packages; X-ray inspection of these packages provides a viable alternative. This paper presents the results of an investigation into dual-energy X-ray techniques for automated detection of small metal particles in plastic food container packages. The sample packages consist of sealed cardboard boxes containing stacks of food containers: plastic cups for food, and Styrofoam cups for noodles. The primary goal of the investigation was to automatically identify small metal particles down to 0.5 mm diameter in size or less, randomly located within the containers. The multiple container stacks in each box make it virtually impossible to reliably detect the particles with single-energy X-ray techniques either visually or with image processing. The stacks get overlaid in the X-ray image and create many indications almost identical in contrast and size to real metal particles. Dual-energy X-ray techniques were investigated and found to result in a clear separation of the metal particles from the food container stack-ups. Automated image analysis of the resulting images provides reliable detection of the small metal particles.

  16. Computer-Aided Diagnosis of Splenic Enlargement Using Wave Pattern of Spleen in Abdominal CT Images: Initial Observations

    NASA Astrophysics Data System (ADS)

    Seong, Won; Cho, June-Sik; Noh, Seung-Moo; Park, Jong-Won

    In general, the spleen accompanied by abnormal abdomen is hypertrophied. However, if the spleen size is originally small, it is hard to detect the splenic enlargement due to abnormal abdomen by simply measure the size. On the contrary, the spleen size of a person having a normal abdomen may be large by nature. Therefore, measuring the size of spleen is not a reliable diagnostic measure of its enlargement or the abdomen abnormality. This paper proposes an automatic method to diagnose the splenic enlargement due to abnormality, by examining the boundary pattern of spleen in abdominal CT images.

  17. Primary Water Stress Corrosion Cracks in Nickel Alloy Dissimilar Metal Welds: Detection and Sizing Using Established and Emerging Nondestructive Examination Techniques

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Braatz, Brett G.; Cumblidge, Stephen E.; Doctor, Steven R.

    2012-12-31

    The U.S. Nuclear Regulatory Commission has established the Program to Assess the Reliability of Emerging Nondestructive Techniques (PARENT) as a follow-on to the international cooperative Program for the Inspection of Nickel Alloy Components (PINC). The goal of PINC was to evaluate the capabilities of various nondestructive evaluation (NDE) techniques to detect and characterize surface-breaking primary water stress corrosion cracks in dissimilar-metal welds (DMW) in bottom-mounted instrumentation (BMI) penetrations and small-bore (≈400-mm diameter) piping components. A series of international blind round-robin tests were conducted by commercial and university inspection teams. Results from these tests showed that a combination of conventional andmore » phased-array ultrasound techniques provided the highest performance for flaw detection and depth sizing in dissimilar metal piping welds. The effective detection of flaws in BMIs by eddy current and ultrasound shows that it may be possible to reliably inspect these components in the field. The goal of PARENT is to continue the work begun in PINC and apply the lessons learned to a series of open and blind international round-robin tests that will be conducted on a new set of piping components including large-bore (≈900-mm diameter) DMWs, small-bore DMWs, and BMIs. Open round-robin testing will engage universities and industry worldwide to investigate the reliability of emerging NDE techniques to detect and accurately size flaws having a wide range of lengths, depths, orientations, and locations. Blind round-robin testing will invite testing organizations worldwide, whose inspectors and procedures are certified by the standards for the nuclear industry in their respective countries, to investigate the ability of established NDE techniques to detect and size flaws whose characteristics range from easy to very difficult to detect and size. This paper presents highlights of PINC and reports on the plans and progress for PARENT round-robin tests.« less

  18. Reliability of risk-adjusted outcomes for profiling hospital surgical quality.

    PubMed

    Krell, Robert W; Hozain, Ahmed; Kao, Lillian S; Dimick, Justin B

    2014-05-01

    Quality improvement platforms commonly use risk-adjusted morbidity and mortality to profile hospital performance. However, given small hospital caseloads and low event rates for some procedures, it is unclear whether these outcomes reliably reflect hospital performance. To determine the reliability of risk-adjusted morbidity and mortality for hospital performance profiling using clinical registry data. A retrospective cohort study was conducted using data from the American College of Surgeons National Surgical Quality Improvement Program, 2009. Participants included all patients (N = 55,466) who underwent colon resection, pancreatic resection, laparoscopic gastric bypass, ventral hernia repair, abdominal aortic aneurysm repair, and lower extremity bypass. Outcomes included risk-adjusted overall morbidity, severe morbidity, and mortality. We assessed reliability (0-1 scale: 0, completely unreliable; and 1, perfectly reliable) for all 3 outcomes. We also quantified the number of hospitals meeting minimum acceptable reliability thresholds (>0.70, good reliability; and >0.50, fair reliability) for each outcome. For overall morbidity, the most common outcome studied, the mean reliability depended on sample size (ie, how high the hospital caseload was) and the event rate (ie, how frequently the outcome occurred). For example, mean reliability for overall morbidity was low for abdominal aortic aneurysm repair (reliability, 0.29; sample size, 25 cases per year; and event rate, 18.3%). In contrast, mean reliability for overall morbidity was higher for colon resection (reliability, 0.61; sample size, 114 cases per year; and event rate, 26.8%). Colon resection (37.7% of hospitals), pancreatic resection (7.1% of hospitals), and laparoscopic gastric bypass (11.5% of hospitals) were the only procedures for which any hospitals met a reliability threshold of 0.70 for overall morbidity. Because severe morbidity and mortality are less frequent outcomes, their mean reliability was lower, and even fewer hospitals met the thresholds for minimum reliability. Most commonly reported outcome measures have low reliability for differentiating hospital performance. This is especially important for clinical registries that sample rather than collect 100% of cases, which can limit hospital case accrual. Eliminating sampling to achieve the highest possible caseloads, adjusting for reliability, and using advanced modeling strategies (eg, hierarchical modeling) are necessary for clinical registries to increase their benchmarking reliability.

  19. Learned perceptual associations influence visuomotor programming under limited conditions: kinematic consistency.

    PubMed

    Haffenden, Angela M; Goodale, Melvyn A

    2002-12-01

    Previous findings have suggested that visuomotor programming can make use of learned size information in experimental paradigms where movement kinematics are quite consistent from trial to trial. The present experiment was designed to test whether or not this conclusion could be generalized to a different manipulation of kinematic variability. As in previous work, an association was established between the size and colour of square blocks (e.g. red = large; yellow = small, or vice versa). Associating size and colour in this fashion has been shown to reliably alter the perceived size of two test blocks halfway in size between the large and small blocks: estimations of the test block matched in colour to the group of large blocks are smaller than estimations of the test block matched to the group of small blocks. Subjects grasped the blocks, and on other trials estimated the size of the blocks. These changes in perceived block size were incorporated into grip scaling only when movement kinematics were highly consistent from trial to trial; that is, when the blocks were presented in the same location on each trial. When the blocks were presented in different locations grip scaling remained true to the metrics of the test blocks despite the changes in perceptual estimates of block size. These results support previous findings suggesting that kinematic consistency facilitates the incorporation of learned perceptual information into grip scaling.

  20. Detection of small-size solder ball defects through heat conduction analysis

    NASA Astrophysics Data System (ADS)

    Zhou, Xiuyun; Chen, Yaqiu; Lu, Xiaochuan

    2018-02-01

    Aiming to solve the defect detection problem of a small-size solder ball in the high density chip, heat conduction analysis based on eddy current pulsed thermography is put forward to differentiate various defects. With establishing the 3D finite element model about induction heating, defects such as cracks and void can be distinguished by temperature difference resulting from heat conduction. Furthermore, the experiment of 0.4 mm-diameter solder balls with different defects is carried out to prove that crack and void solder can be distinguished. Three kinds of crack length on a gull-wing pin are selected, including 0.24 mm, 1.2 mm, and 2.16 mm, to verify that the small defect can be discriminated. Both the simulation study and experiment result show that the heat conduction analysis method is reliable and convenient.

  1. Earthquake Damage Assessment Using Very High Resolution Satelliteimagery

    NASA Astrophysics Data System (ADS)

    Chiroiu, L.; André, G.; Bahoken, F.; Guillande, R.

    Various studies using satellite imagery were applied in the last years in order to assess natural hazard damages, most of them analyzing the case of floods, hurricanes or landslides. For the case of earthquakes, the medium or small spatial resolution data available in the recent past did not allow a reliable identification of damages, due to the size of the elements (e.g. buildings or other structures), too small compared with the pixel size. The recent progresses of remote sensing in terms of spatial resolution and data processing makes possible a reliable damage detection to the elements at risk. Remote sensing techniques applied to IKONOS (1 meter resolution) and IRS (5 meters resolution) imagery were used in order to evaluate seismic vulnerability and post earthquake damages. A fast estimation of losses was performed using a multidisciplinary approach based on earthquake engineering and geospatial analysis. The results, integrated into a GIS database, could be transferred via satellite networks to the rescue teams deployed on the affected zone, in order to better coordinate the emergency operations. The methodology was applied to the city of Bhuj and Anjar after the 2001 Gujarat (India) Earthquake.

  2. A Meta-Analytic Review of Stand-Alone Interventions to Improve Body Image

    PubMed Central

    Alleva, Jessica M.; Sheeran, Paschal; Webb, Thomas L.; Martijn, Carolien; Miles, Eleanor

    2015-01-01

    Objective Numerous stand-alone interventions to improve body image have been developed. The present review used meta-analysis to estimate the effectiveness of such interventions, and to identify the specific change techniques that lead to improvement in body image. Methods The inclusion criteria were that (a) the intervention was stand-alone (i.e., solely focused on improving body image), (b) a control group was used, (c) participants were randomly assigned to conditions, and (d) at least one pretest and one posttest measure of body image was taken. Effect sizes were meta-analysed and moderator analyses were conducted. A taxonomy of 48 change techniques used in interventions targeted at body image was developed; all interventions were coded using this taxonomy. Results The literature search identified 62 tests of interventions (N = 3,846). Interventions produced a small-to-medium improvement in body image (d + = 0.38), a small-to-medium reduction in beauty ideal internalisation (d + = -0.37), and a large reduction in social comparison tendencies (d + = -0.72). However, the effect size for body image was inflated by bias both within and across studies, and was reliable but of small magnitude once corrections for bias were applied. Effect sizes for the other outcomes were no longer reliable once corrections for bias were applied. Several features of the sample, intervention, and methodology moderated intervention effects. Twelve change techniques were associated with improvements in body image, and three techniques were contra-indicated. Conclusions The findings show that interventions engender only small improvements in body image, and underline the need for large-scale, high-quality trials in this area. The review identifies effective techniques that could be deployed in future interventions. PMID:26418470

  3. Incorporating Biological Knowledge into Evaluation of Casual Regulatory Hypothesis

    NASA Technical Reports Server (NTRS)

    Chrisman, Lonnie; Langley, Pat; Bay, Stephen; Pohorille, Andrew; DeVincenzi, D. (Technical Monitor)

    2002-01-01

    Biological data can be scarce and costly to obtain. The small number of samples available typically limits statistical power and makes reliable inference of causal relations extremely difficult. However, we argue that statistical power can be increased substantially by incorporating prior knowledge and data from diverse sources. We present a Bayesian framework that combines information from different sources and we show empirically that this lets one make correct causal inferences with small sample sizes that otherwise would be impossible.

  4. ELROI Extremely Low Resource Optical Identifier. A license plate for your satellite, and more.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Palmer, David

    ELROI (Extremely Low Resource Optical Identifier) is a license plate for your satellite; a small tag that flashes an optical identification code that can be read by a small telescope on the ground. The final version of the tag will be the size of a thick postage stamp and fully autonomous: you can attach it to everything that goes into space, including small cubesats and inert debris like rocket stages, and it will keep blinking even after the satellite is shut down, reliably identifying the object from launch until re-entry.

  5. Determination of Minimum Training Sample Size for Microarray-Based Cancer Outcome Prediction–An Empirical Assessment

    PubMed Central

    Cheng, Ningtao; Wu, Leihong; Cheng, Yiyu

    2013-01-01

    The promise of microarray technology in providing prediction classifiers for cancer outcome estimation has been confirmed by a number of demonstrable successes. However, the reliability of prediction results relies heavily on the accuracy of statistical parameters involved in classifiers. It cannot be reliably estimated with only a small number of training samples. Therefore, it is of vital importance to determine the minimum number of training samples and to ensure the clinical value of microarrays in cancer outcome prediction. We evaluated the impact of training sample size on model performance extensively based on 3 large-scale cancer microarray datasets provided by the second phase of MicroArray Quality Control project (MAQC-II). An SSNR-based (scale of signal-to-noise ratio) protocol was proposed in this study for minimum training sample size determination. External validation results based on another 3 cancer datasets confirmed that the SSNR-based approach could not only determine the minimum number of training samples efficiently, but also provide a valuable strategy for estimating the underlying performance of classifiers in advance. Once translated into clinical routine applications, the SSNR-based protocol would provide great convenience in microarray-based cancer outcome prediction in improving classifier reliability. PMID:23861920

  6. COTS Ceramic Chip Capacitors: An Evaluation of the Parts and Assurance Methodologies

    NASA Technical Reports Server (NTRS)

    Brusse, Jay A.; Sampson, Michael J.

    2004-01-01

    Commercial-Off-The-Shelf (COTS) multilayer ceramic chip capacitors (MLCCs) are continually evolving to reduce physical size and increase volumetric efficiency. Designers of high reliability aerospace and military systems are attracted to these attributes of COTS MLCCs and would like to take advantage of them while maintaining the high standards for long-term reliable operation they are accustomed io when selecting military qualified established reliability (MIL-ER) MLCCs. However, MIL-ER MLCCs are not available in the full range of small chip sizes with high capacitance as found in today's COTS MLCCs. The objectives for this evaluation were to assess the long-term performance of small case size COTS MLCCs and to identify effective, lower-cost product assurance methodologies. Fifteen (15) lots of COTS X7R dielectric MLCCs from four (4) different manufacturers and two (2) MIL-ER BX dielectric MLCCs from two (2) of the same manufacturers were evaluated. Both 0805 and 0402 chip sizes were included. Several voltage ratings were tested ranging from a high of 50 volts to a low of 6.3 volts. The evaluation consisted of a comprehensive screening and qualification test program based upon MIL-PRF-55681 (i.e., voltage conditioning, thermal shock, moisture resistance, 2000-hour life test, etc.). In addition, several lot characterization tests were performed including Destructive Physical Analysis (DPA), Highly Accelerated Life Test (HALT) and Dielectric Voltage Breakdown Strength. The data analysis included a comparison of the 2000-hour life test results (used as a metric for long-term performance) relative to the screening and characterization test results. Results of this analysis indicate that the long-term life performance of COTS MLCCs is variable -- some lots perform well, some lots perform poorly. DPA and HALT were found to be promising lot characterization tests to identify substandard COTS MLCC lots prior to conducting more expensive screening and qualification tests. The results indicate that lot- specific screening and qualification are still recommended for high reliability applications. One significant and concerning observation is that MIL- type voltage conditioning (100 hours at twice rated voltage, 125 C) was not an effective screen in removing infant mortality parts for the particular lots of COTS MLCCs evaluated.

  7. Low-frequency switching voltage regulators for terrestrial photovoltaic systems

    NASA Technical Reports Server (NTRS)

    Delombard, R.

    1984-01-01

    The photovoltaic technology project and the stand alone applications project are discussed. Two types of low frequency switching type regulators were investigated. The design, operating characteristics and field application of these regulators is described. The regulators are small in size, low in cost, very low in power dissipation, reliable and allow considerable flexibility in system design.

  8. Phase transition of charged-AdS black holes and quasinormal modes: A time domain analysis

    NASA Astrophysics Data System (ADS)

    Chabab, M.; El Moumni, H.; Iraoui, S.; Masmar, K.

    2017-10-01

    In this work, we investigate the time evolution of a massless scalar perturbation around small and large RN-AdS4 black holes for the purpose of probing the thermodynamic phase transition. We show that below the critical point the scalar perturbation decays faster with increasing of the black hole size, both for small and large black hole phases. Our analysis of the time profile of quasinormal mode reveals a sharp distinction between the behaviors of both phases, providing a reliable tool to probe the black hole phase transition. However at the critical point P=Pc, as the black hole size extends, we note that the damping time increases and the perturbation decays faster, the oscillation frequencies raise either in small and large black hole phase. In this case the time evolution approach fails to track the AdS4 black hole phase.

  9. The usefulness of oncoplastic volume displacement techniques in the superiorly located breast cancers for Korean patients with small to moderate-sized breasts.

    PubMed

    Yang, Jung Dug; Bae, Sung Gun; Chung, Ho Yun; Cho, Byung Chae; Park, Ho Yong; Jung, Jin Hyang

    2011-11-01

    Because the average breast size of Korean women is not as large as that of western women, it is not so easy to apply the oncoplastic volume displacement technique. However, we have tried to use volume displacement techniques that work well with small-breasted women. In this study, we report the usefulness of displacement techniques in the superiorly located cancers with small- to moderate-sized breasts. Between September 2006 and August 2009, 58 women were treated for superiorly located cancers. All patients who were selected had small- to moderate-sized breasts and small to moderate breast defects. They were divided into 3 groups. The groups were split based on the distance from the nipple-areolar complex, which are as follows: near, intermediate, and far. Their mean age was 46 and the average follow-up interval was 21 months. Median weight of the specimen on the tumor side was 84 g (range, 29-140 g). The various surgical techniques used were the "round block" technique (n = 8) and "batwing mastopexy" (n = 4) for near lesions; "tennis racket" method (n = 32) and "rotational flap" (n = 8) for intermediate lesions; and "parallelogram mastopexy lumpectomy" (n = 6) for far lesions. There were 4 complications (nipple-areolar complex partial necrosis, radiation burn, and 2 wound dehiscence). No local recurrences have been observed and a majority of the patients were satisfied with cosmetic results. Oncoplastic volume displacement techniques in superiorly located breast cancers for Korean patients with small- to moderate-sized breast are reliable and should be considered in the case of breast conserving surgery (BCS).

  10. A reliable sealing method for microbatteries

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, Yuxing; Cartmell, Samuel; Li, Qiuyan

    2017-02-01

    With continuous downsizing of electronic devices, lithium batteries of traditional shapes cannot meet the demand where small-size high energy density batteries are needed. Conventional sealing methods become increasingly difficult to apply and impose high processing cost as the size of batteries decreases. In this report, a facile sealing method is proposed and demonstrated in CFx/Li mini-batteries. The method employs a temporary barrier to liquid electrolytes while relies on the epoxies/cell casings bond for the hermetic sealing. Cells sealed by this method show no degradation for an extended period of storage time.

  11. New VCSEL technology with scalability for single mode operation and densely integrated arrays

    NASA Astrophysics Data System (ADS)

    Zhao, Guowei; Demir, Abdullah; Freisem, Sabine; Zhang, Yu; Liu, Xiaohang; Deppe, Dennis G.

    2011-06-01

    Data are presented demonstrating a new lithographic vertical-cavity surface-emitting laser (VCSEL) technology, which produces simultaneous mode- and current-confinement only by lithography and epitaxial crystal growth. The devices are grown by solid source molecular beam epitaxy, and have lithographically defined sizes that vary from 3 μm to 20 μm. The lithographic process allows the devices to have high uniformity throughout the wafer and scalability to very small size. The 3 μm device shows a threshold current of 310 μA, the slope efficiency of 0.81 W/A, and the maximum output power of more than 5 mW. The 3 μm device also shows single-mode single-polarization operation without the use of surface grating, and has over 25 dB side-mode-suppression-ratio up to 1 mW of output power. The devices have low thermal resistance due to the elimination of oxide aperture. High reliability is achieved by removal of internal strain caused by the oxide, stress test shows no degradation for the 3 μm device operating at very high injection current level of 142 kA/cm2 for 1000 hours, while at this dive level commercial VCSELs fail rapidly. The lithographic VCSEL technology can lead to manufacture of reliable small size laser diode, which will have application in large area 2-D arrays and low power sensors.

  12. School Improvement Should Rely on Reliable, Scientific Evidence. Why Did "No Child Left Behind" Leave Class Size Behind?

    ERIC Educational Resources Information Center

    Achilles, C. M.; Krieger, Jean D.; Finn, J. D.; Sharp, Mark

    Small classes in grades K-3 boost student academic performance in all subjects and in prosocial behavior. Results are both short- and long-term. One study explored the theory that a major cause behind improved academic achievement involves improved student behavior, which increases student engagement in the classroom. Two other studies provide…

  13. The Dependability of the General Factor of Intelligence: Why Small, Single-Factor Models Do Not Adequately Represent "g"

    ERIC Educational Resources Information Center

    Major, Jason T.; Johnson, Wendy; Bouchard, Thomas J., Jr.

    2011-01-01

    Floyd, Shands, Rafael, Bergeron and McGrew (2009) used generalizability theory to test the reliability of general-factor loadings and to compare three different sources of error in them: the test battery size, the test battery composition, the factor-extraction technique, and their interactions. They found that their general-factor loadings were…

  14. High-performance liquid chromatographic method for the determination of dansyl-polyamines

    Treesearch

    Subhash C. Minocha; Rakesh Minocha; Cheryl A. Robie

    1990-01-01

    This paper describes a fast reliable, and a sensitive technique for the separation and quantification of dansylated polyamines by high-performance liquid chromatography. Using a small 33 x 4.6 mm I.D., 3 ?m particle size, C18 reversed-phase cartridge column and a linear gradient of acetonitrile-heptanesulfonate (10 mM, pH 3.4...

  15. Identification of Intensity Ratio Break Points from Photon Arrival Trajectories in Ratiometric Single Molecule Spectroscopy

    PubMed Central

    Bingemann, Dieter; Allen, Rachel M.

    2012-01-01

    We describe a statistical method to analyze dual-channel photon arrival trajectories from single molecule spectroscopy model-free to identify break points in the intensity ratio. Photons are binned with a short bin size to calculate the logarithm of the intensity ratio for each bin. Stochastic photon counting noise leads to a near-normal distribution of this logarithm and the standard student t-test is used to find statistically significant changes in this quantity. In stochastic simulations we determine the significance threshold for the t-test’s p-value at a given level of confidence. We test the method’s sensitivity and accuracy indicating that the analysis reliably locates break points with significant changes in the intensity ratio with little or no error in realistic trajectories with large numbers of small change points, while still identifying a large fraction of the frequent break points with small intensity changes. Based on these results we present an approach to estimate confidence intervals for the identified break point locations and recommend a bin size to choose for the analysis. The method proves powerful and reliable in the analysis of simulated and actual data of single molecule reorientation in a glassy matrix. PMID:22837704

  16. A Comparison of the Results from General Tank Tests of 1/6- and 1/12-full-size Models of the British Singapore IIC Flying Boat

    NASA Technical Reports Server (NTRS)

    Truscott, Starr; Dawson, John R

    1942-01-01

    A 1/6-full-size model of the hull of the British Singapore IIC flying boat was tested in the NACA tank. The results are given in the form of charts and are compared with the results of previous tests made in the NACA tank of a 1/12-full-size model, published in NACA T.N. No. 580, and with the results of tests made in the British R.A.E. tank of another 1/6-full-size model of the same hull. When the data from the tests of the 1/6- and 1/12-full-size models were compared on the basis of Froude's law of comparison, differences were found. This fact supported the belief that the small scale of the model and the use of a model that was too small to suit the equipment of the NACA tank had caused the results of the tests of the 1/12-full-size model to be less reliable than the results of the tests of the 1/6-full-size model. The results of the tests of the two models agreed sufficiently well to show that test of a small model, if made meticulously and with suitable equipment, may give useable results, but that a larger model should be used whenever feasible. The results of the NACA tests of the 1/6-full-size model were found to be in good agreement with the R.A.E. tests of a model of the same size.

  17. Modeling the X-Ray Process, and X-Ray Flaw Size Parameter for POD Studies

    NASA Technical Reports Server (NTRS)

    Khoshti, Ajay

    2014-01-01

    Nondestructive evaluation (NDE) method reliability can be determined by a statistical flaw detection study called probability of detection (POD) study. In many instances the NDE flaw detectability is given as a flaw size such as crack length. The flaw is either a crack or behaving like a crack in terms of affecting the structural integrity of the material. An alternate approach is to use a more complex flaw size parameter. The X-ray flaw size parameter, given here, takes into account many setup and geometric factors. The flaw size parameter relates to X-ray image contrast and is intended to have a monotonic correlation with the POD. Some factors such as set-up parameters including X-ray energy, exposure, detector sensitivity, and material type that are not accounted for in the flaw size parameter may be accounted for in the technique calibration and controlled to meet certain quality requirements. The proposed flaw size parameter and the computer application described here give an alternate approach to conduct the POD studies. Results of the POD study can be applied to reliably detect small flaws through better assessment of effect of interaction between various geometric parameters on the flaw detectability. Moreover, a contrast simulation algorithm for a simple part-source-detector geometry using calibration data is also provided for the POD estimation.

  18. Modeling the X-ray Process, and X-ray Flaw Size Parameter for POD Studies

    NASA Technical Reports Server (NTRS)

    Koshti, Ajay M.

    2014-01-01

    Nondestructive evaluation (NDE) method reliability can be determined by a statistical flaw detection study called probability of detection (POD) study. In many instances, the NDE flaw detectability is given as a flaw size such as crack length. The flaw is either a crack or behaving like a crack in terms of affecting the structural integrity of the material. An alternate approach is to use a more complex flaw size parameter. The X-ray flaw size parameter, given here, takes into account many setup and geometric factors. The flaw size parameter relates to X-ray image contrast and is intended to have a monotonic correlation with the POD. Some factors such as set-up parameters, including X-ray energy, exposure, detector sensitivity, and material type that are not accounted for in the flaw size parameter may be accounted for in the technique calibration and controlled to meet certain quality requirements. The proposed flaw size parameter and the computer application described here give an alternate approach to conduct the POD studies. Results of the POD study can be applied to reliably detect small flaws through better assessment of effect of interaction between various geometric parameters on the flaw detectability. Moreover, a contrast simulation algorithm for a simple part-source-detector geometry using calibration data is also provided for the POD estimation.

  19. The comparison of predictive scheduling algorithms for different sizes of job shop scheduling problems

    NASA Astrophysics Data System (ADS)

    Paprocka, I.; Kempa, W. M.; Grabowik, C.; Kalinowski, K.; Krenczyk, D.

    2016-08-01

    In the paper a survey of predictive and reactive scheduling methods is done in order to evaluate how the ability of prediction of reliability characteristics influences over robustness criteria. The most important reliability characteristics are: Mean Time to Failure, Mean Time of Repair. Survey analysis is done for a job shop scheduling problem. The paper answers the question: what method generates robust schedules in the case of a bottleneck failure occurrence before, at the beginning of planned maintenance actions or after planned maintenance actions? Efficiency of predictive schedules is evaluated using criteria: makespan, total tardiness, flow time, idle time. Efficiency of reactive schedules is evaluated using: solution robustness criterion and quality robustness criterion. This paper is the continuation of the research conducted in the paper [1], where the survey of predictive and reactive scheduling methods is done only for small size scheduling problems.

  20. Different MR features for differentiation of intrahepatic mass-forming cholangiocarcinoma from hepatocellular carcinoma according to tumor size.

    PubMed

    Ni, Ting; Shang, Xiao-Sha; Wang, Wen-Tao; Hu, Xin-Xing; Zeng, Meng-Su; Rao, Sheng-Xiang

    2018-06-05

    To identify reliable magnetic resonance (MR) features for distinguishing mass-forming type of intrahepatic cholangiocarcinoma (IMCC) from hepatocellular carcinoma (HCC) based on tumor size. This retrospective study included 395 patients with pathologically confirmed IMCCs (n = 180) and HCCs (n = 215) who underwent pre-operative contrast-enhanced MRI including diffusion-weighted imaging (DWI). MR features were evaluated and clinical data were also recorded. All the characteristics were compared in small (≤3 cm) and large tumor (>3 cm) groups by univariate analysis and subsequently calculated by multivariable logistic regression analysis. Multivariable analysis revealed that rim arterial phase hyperenhancement [odds ratios (ORs) = 13.16], biliary dilation (OR = 23.42) and CA19-9 (OR = 21.45) were significant predictors of large IMCCs (n = 138), and washout appearance (OR = 0.036), enhancing capsule appearance (OR = 0.039), fat in mass (OR = 0.057), chronic liver disease (OR = 0.088) and alpha fetoprotein (OR = 0.019) were more frequently found in large HCCs (n = 143). For small IMCCs (n = 42) and HCCs (n = 72), rim arterial phase hyperenhancement (OR = 9.68), target appearance at DWI (OR = 12.51), alpha fetoprotein (OR = 0.12) and sex (OR = 0.20) were independent predictors in multivariate analysis. Valuable MR features and clinical factors varied for differential diagnosis of IMCCs and HCCs according to tumor size. Advances in knowledge: MR features for differential diagnosis of large IMCC and HCC (>3 cm) are in keeping with that recommended by LI-RADS. However, for small IMCCs and HCCs (≤3 cm), only rim enhancement on arterial phase and target appearance at DWI are reliable predictors.

  1. SIERRA - A 3-D device simulator for reliability modeling

    NASA Astrophysics Data System (ADS)

    Chern, Jue-Hsien; Arledge, Lawrence A., Jr.; Yang, Ping; Maeda, John T.

    1989-05-01

    SIERRA is a three-dimensional general-purpose semiconductor-device simulation program which serves as a foundation for investigating integrated-circuit (IC) device and reliability issues. This program solves the Poisson and continuity equations in silicon under dc, transient, and small-signal conditions. Executing on a vector/parallel minisupercomputer, SIERRA utilizes a matrix solver which uses an incomplete LU (ILU) preconditioned conjugate gradient square (CGS, BCG) method. The ILU-CGS method provides a good compromise between memory size and convergence rate. The authors have observed a 5x to 7x speedup over standard direct methods in simulations of transient problems containing highly coupled Poisson and continuity equations such as those found in reliability-oriented simulations. The application of SIERRA to parasitic CMOS latchup and dynamic random-access memory single-event-upset studies is described.

  2. Oviposition substrate in Asian tiger mosquito surveillance: Do the sizes matter?

    PubMed

    Falsone, Luigi; Brianti, Emanuele; Severini, Francesco; Giannetto, Salvatore; Romi, Roberto

    2015-12-01

    Ovitraps are regarded as a reliable system to monitor Aedes albopictus dynamics. However, the dimensions of the oviposition substrate are not standardized, and no studies have investigated which should be the most effective sizes. In this study, the effect of paddle sizes in tiger mosquito egg collection was evaluated. Egg count and density on the wide surfaces and margins of different-sized oviposition substrates have been evaluated in two studies (A and B). In study A, a total of 29,995 Ae. albopictus eggs was counted in 250 classic oviposition substrates. Eggs were found on both wide surfaces (53.1%) and margins (46.9%). Egg density was significantly larger in margins compared to wide surfaces. Overall in study B, 983 Ae. albopictus eggs were collected. According to paddle sizes, 51.8% of eggs were on large and 48.2% on small paddles. Mean egg density of wide surfaces was significantly larger in small paddles (0.25 eggs/cm(2) ) compared to large paddles (0.06 eggs/cm(2) ). Results indicate that wider oviposition substrates do not mean larger number of Ae. albopictus eggs. Indeed, on paddles four times thinner than others, the number of eggs counted was not statistically different. These findings suggest that small paddles may be routinely employed in ovitraps, thus allowing savings of materials and money. © 2015 The Society for Vector Ecology.

  3. [Meta analysis of variables related to attention deficit hyperactivity disorder in school-age children].

    PubMed

    Park, Wan Ju; Seo, Ji Yeong; Kim, Mi Ye

    2011-04-01

    The purpose of this study was to use meta-analysis to examine recent domestic articles related to attention deficit hyperactivity disorder (ADHD) in school-age children. After reviewing 213 articles published between 1990 and 2009 from and cited in RISS, KISS, and DBpia, the researchers identified 24 studies with 440 research variables that had appropriate data for methodological study. SPSS 17.0 program was used. The outcome variables were divided into five types: Inattention, hyperactive impulsive, intrinsic, extrinsic, and academic ability variables. Effects size of overall core symptoms was 0.47 which is moderate level in terms of Cohen criteria and effects size of overall negative variables related ADHD was 0.27 which is small level. The most dominant variable related to ADHD was obtained from hyperactive-impulsive (0.70). Also academic ability (0.45), inattention (0.37), and intrinsic variables (0.29) had a small effect whereas extrinsic variables (0.13) had little effect on descriptive ADHD study. The results reveal that ADHD core symptoms have moderate effect size and peripheral negative variables related ADHD have small effect size. To improve the reliability of the meta-analysis results by minimizing publication bias, more intervention studies using appropriate study designs should be done.

  4. In Situ Study on the Evolution of Multimodal Particle Size Distributions of ZnO Quantum Dots: Some General Rules for the Occurrence of Multimodalities.

    PubMed

    Schindler, Torben; Walter, Johannes; Peukert, Wolfgang; Segets, Doris; Unruh, Tobias

    2015-12-10

    Properties of small semiconductor nanoparticles (NPs) are strongly governed by their size. Precise characterization is a key requirement for tailored dispersities and thus for high-quality devices. Results of a careful analysis of particle size distributions (PSDs) of ZnO are presented combining advantages of UV/vis absorption spectroscopy, analytical ultracentrifugation, and small-angle X-ray scattering (SAXS). Our study reveals that careful cross-validation of these different methods is mandatory to end up with reliable resolution. PSDs of ZnO NPs are multimodal on a size range of 2-8 nm, a finding that is not yet sufficiently addressed. In the second part of our work the evolution of PSDs was studied using in situ SAXS. General principles for the appearance of multimodalities covering a temperature range between 15 and 45 °C were found which are solely determined by the aging state indicated by the size of the medium-sized fraction. Whenever this fraction exceeds a critical diameter, a new multimodality is identified, independent of the particular time-temperature combination. A fraction of larger particles aggregates first before a fraction of smaller particles is detected. Fixed multimodalities have not yet been addressed adequately and could only be evidenced due to careful size analysis.

  5. Influence of cue word perceptual information on metamemory accuracy in judgement of learning.

    PubMed

    Hu, Xiao; Liu, Zhaomin; Li, Tongtong; Luo, Liang

    2016-01-01

    Previous studies have suggested that perceptual information regarding to-be-remembered words in the study phase affects the accuracy of judgement of learning (JOL). However, few have investigated whether the perceptual information in the JOL phase influences JOL accuracy. This study examined the influence of cue word perceptual information in the JOL phase on immediate and delayed JOL accuracy through changes in cue word font size. In Experiment 1, large-cue word pairs had significantly higher mean JOL magnitude than small-cue word pairs in immediate JOLs and higher relative accuracy than small-cue pairs in delayed JOLs, but font size had no influence on recall performance. Experiment 2 increased the JOL time, and mean JOL magnitude did not reliably differ for large-cue compared with small-cue pairs in immediate JOLs. However, the influence on relative accuracy still existed in delayed JOLs. Experiment 3 increased the familiarity of small-cue words in the delayed JOL phase by adding a lexical decision task. The results indicated that cue word font size no longer affected relative accuracy in delayed JOLs. The three experiments in our study indicated that the perceptual information regarding cue words in the JOL phase affects immediate and delayed JOLs in different ways.

  6. Design and Validation of High Date Rate Ka-Band Software Defined Radio for Small Satellite

    NASA Technical Reports Server (NTRS)

    Xia, Tian

    2016-01-01

    The Design and Validation of High Date Rate Ka- Band Software Defined Radio for Small Satellite project will develop a novel Ka-band software defined radio (SDR) that is capable of establishing high data rate inter-satellite links with a throughput of 500 megabits per second (Mb/s) and providing millimeter ranging precision. The system will be designed to operate with high performance and reliability that is robust against various interference effects and network anomalies. The Ka-band radio resulting from this work will improve upon state of the art Ka-band radios in terms of dimensional size, mass and power dissipation, which limit their use in small satellites.

  7. Overcoming time scale and finite size limitations to compute nucleation rates from small scale well tempered metadynamics simulations.

    PubMed

    Salvalaglio, Matteo; Tiwary, Pratyush; Maggioni, Giovanni Maria; Mazzotti, Marco; Parrinello, Michele

    2016-12-07

    Condensation of a liquid droplet from a supersaturated vapour phase is initiated by a prototypical nucleation event. As such it is challenging to compute its rate from atomistic molecular dynamics simulations. In fact at realistic supersaturation conditions condensation occurs on time scales that far exceed what can be reached with conventional molecular dynamics methods. Another known problem in this context is the distortion of the free energy profile associated to nucleation due to the small, finite size of typical simulation boxes. In this work the problem of time scale is addressed with a recently developed enhanced sampling method while contextually correcting for finite size effects. We demonstrate our approach by studying the condensation of argon, and showing that characteristic nucleation times of the order of magnitude of hours can be reliably calculated. Nucleation rates spanning a range of 10 orders of magnitude are computed at moderate supersaturation levels, thus bridging the gap between what standard molecular dynamics simulations can do and real physical systems.

  8. Overcoming time scale and finite size limitations to compute nucleation rates from small scale well tempered metadynamics simulations

    NASA Astrophysics Data System (ADS)

    Salvalaglio, Matteo; Tiwary, Pratyush; Maggioni, Giovanni Maria; Mazzotti, Marco; Parrinello, Michele

    2016-12-01

    Condensation of a liquid droplet from a supersaturated vapour phase is initiated by a prototypical nucleation event. As such it is challenging to compute its rate from atomistic molecular dynamics simulations. In fact at realistic supersaturation conditions condensation occurs on time scales that far exceed what can be reached with conventional molecular dynamics methods. Another known problem in this context is the distortion of the free energy profile associated to nucleation due to the small, finite size of typical simulation boxes. In this work the problem of time scale is addressed with a recently developed enhanced sampling method while contextually correcting for finite size effects. We demonstrate our approach by studying the condensation of argon, and showing that characteristic nucleation times of the order of magnitude of hours can be reliably calculated. Nucleation rates spanning a range of 10 orders of magnitude are computed at moderate supersaturation levels, thus bridging the gap between what standard molecular dynamics simulations can do and real physical systems.

  9. Study of vesicle size distribution dependence on pH value based on nanopore resistive pulse method

    NASA Astrophysics Data System (ADS)

    Lin, Yuqing; Rudzevich, Yauheni; Wearne, Adam; Lumpkin, Daniel; Morales, Joselyn; Nemec, Kathleen; Tatulian, Suren; Lupan, Oleg; Chow, Lee

    2013-03-01

    Vesicles are low-micron to sub-micron spheres formed by a lipid bilayer shell and serve as potential vehicles for drug delivery. The size of vesicle is proposed to be one of the instrumental variables affecting delivery efficiency since the size is correlated to factors like circulation and residence time in blood, the rate for cell endocytosis, and efficiency in cell targeting. In this work, we demonstrate accessible and reliable detection and size distribution measurement employing a glass nanopore device based on the resistive pulse method. This novel method enables us to investigate the size distribution dependence of pH difference across the membrane of vesicles with very small sample volume and rapid speed. This provides useful information for optimizing the efficiency of drug delivery in a pH sensitive environment.

  10. Confidence intervals for the population mean tailored to small sample sizes, with applications to survey sampling.

    PubMed

    Rosenblum, Michael A; Laan, Mark J van der

    2009-01-07

    The validity of standard confidence intervals constructed in survey sampling is based on the central limit theorem. For small sample sizes, the central limit theorem may give a poor approximation, resulting in confidence intervals that are misleading. We discuss this issue and propose methods for constructing confidence intervals for the population mean tailored to small sample sizes. We present a simple approach for constructing confidence intervals for the population mean based on tail bounds for the sample mean that are correct for all sample sizes. Bernstein's inequality provides one such tail bound. The resulting confidence intervals have guaranteed coverage probability under much weaker assumptions than are required for standard methods. A drawback of this approach, as we show, is that these confidence intervals are often quite wide. In response to this, we present a method for constructing much narrower confidence intervals, which are better suited for practical applications, and that are still more robust than confidence intervals based on standard methods, when dealing with small sample sizes. We show how to extend our approaches to much more general estimation problems than estimating the sample mean. We describe how these methods can be used to obtain more reliable confidence intervals in survey sampling. As a concrete example, we construct confidence intervals using our methods for the number of violent deaths between March 2003 and July 2006 in Iraq, based on data from the study "Mortality after the 2003 invasion of Iraq: A cross sectional cluster sample survey," by Burnham et al. (2006).

  11. Reliable evaluation of the quantal determinants of synaptic efficacy using Bayesian analysis

    PubMed Central

    Beato, M.

    2013-01-01

    Communication between neurones in the central nervous system depends on synaptic transmission. The efficacy of synapses is determined by pre- and postsynaptic factors that can be characterized using quantal parameters such as the probability of neurotransmitter release, number of release sites, and quantal size. Existing methods of estimating the quantal parameters based on multiple probability fluctuation analysis (MPFA) are limited by their requirement for long recordings to acquire substantial data sets. We therefore devised an algorithm, termed Bayesian Quantal Analysis (BQA), that can yield accurate estimates of the quantal parameters from data sets of as small a size as 60 observations for each of only 2 conditions of release probability. Computer simulations are used to compare its performance in accuracy with that of MPFA, while varying the number of observations and the simulated range in release probability. We challenge BQA with realistic complexities characteristic of complex synapses, such as increases in the intra- or intersite variances, and heterogeneity in release probabilities. Finally, we validate the method using experimental data obtained from electrophysiological recordings to show that the effect of an antagonist on postsynaptic receptors is correctly characterized by BQA by a specific reduction in the estimates of quantal size. Since BQA routinely yields reliable estimates of the quantal parameters from small data sets, it is ideally suited to identify the locus of synaptic plasticity for experiments in which repeated manipulations of the recording environment are unfeasible. PMID:23076101

  12. Development of 3000 m Subsea Blowout Preventer Experimental Prototype

    NASA Astrophysics Data System (ADS)

    Cai, Baoping; Liu, Yonghong; Huang, Zhiqian; Ma, Yunpeng; Zhao, Yubin

    2017-12-01

    A subsea blowout preventer experimental prototype is developed to meet the requirement of training operators, and the prototype consists of hydraulic control system, electronic control system and small-sized blowout preventer stack. Both the hydraulic control system and the electronic system are dual-mode redundant systems. Each system works independently and is switchable when there are any malfunctions. And it significantly improves the operation reliability of the equipment.

  13. Research@ARL. Imaging & Image Processing. Volume 3, Issue 1

    DTIC Science & Technology

    2014-01-01

    goal, the focal plane arrays (FPAs) the Army deploys must excel in all areas of performance including thermal sensitivity, image resolution, speed of...are available only in relatively small sizes. Further, the difference in thermal expansion coefficients between a CZT substrate and its silicon (Si...read-out integrated circuitry reduces the reliability of large format FPAs due to repeated thermal cycling. Some in the community believed this

  14. Kepler's Final Survey Catalog

    NASA Astrophysics Data System (ADS)

    Mullally, S. E.

    2017-12-01

    The Kepler mission was designed to detect transiting exoplanets and has succeeded in finding over 4000 candidates. These candidates include approximately 50 terrestrial-sized worlds near to the habitable zone of their GKM dwarf stars (shown in figure against the stellar temperature). However not all transit detections are created equal. False positives, such as background eclipsing binaries, can mimic the signal of a transiting planet. Additionally, at Kepler's detection limit noise, either from the star or from the detector, can create signals that also mimic a transiting planet. For the data release 25 Kepler catalog we simulated these false alarms and determined how often known false alarms are called candidates. When this reliability information is combined with our studies of catalog completeness, this catalog can be used to understand the occurrence rate of exoplanets, even for the small, temperate planet candidates found by Kepler. I will discuss the automated methods we used to create and characterize this latest catalog, highlighting how we balanced the completeness and reliability of the long period candidates. While Kepler has been very successful at detecting transiting terrestrial-sized exoplanets, many of these detections are around stars that are too dim for successful follow-up work. Future missions will pick up where Kepler left off and find small planets around some of the brightest and smallest stars.

  15. Power Quality and Reliability Project

    NASA Technical Reports Server (NTRS)

    Attia, John O.

    2001-01-01

    One area where universities and industry can link is in the area of power systems reliability and quality - key concepts in the commercial, industrial and public sector engineering environments. Prairie View A&M University (PVAMU) has established a collaborative relationship with the University of'Texas at Arlington (UTA), NASA/Johnson Space Center (JSC), and EP&C Engineering and Technology Group (EP&C) a small disadvantage business that specializes in power quality and engineering services. The primary goal of this collaboration is to facilitate the development and implementation of a Strategic Integrated power/Systems Reliability and Curriculum Enhancement Program. The objectives of first phase of this work are: (a) to develop a course in power quality and reliability, (b) to use the campus of Prairie View A&M University as a laboratory for the study of systems reliability and quality issues, (c) to provide students with NASA/EPC shadowing and Internship experience. In this work, a course, titled "Reliability Analysis of Electrical Facilities" was developed and taught for two semesters. About thirty seven has benefited directly from this course. A laboratory accompanying the course was also developed. Four facilities at Prairie View A&M University were surveyed. Some tests that were performed are (i) earth-ground testing, (ii) voltage, amperage and harmonics of various panels in the buildings, (iii) checking the wire sizes to see if they were the right size for the load that they were carrying, (iv) vibration tests to test the status of the engines or chillers and water pumps, (v) infrared testing to the test arcing or misfiring of electrical or mechanical systems.

  16. On the reliability of Shewhart-type control charts for multivariate process variability

    NASA Astrophysics Data System (ADS)

    Djauhari, Maman A.; Salleh, Rohayu Mohd; Zolkeply, Zunnaaim; Li, Lee Siaw

    2017-05-01

    We show that in the current practice of multivariate process variability monitoring, the reliability of Shewhart-type control charts cannot be measured except when the sub-group size n tends to infinity. However, the requirement of large n is meaningless not only in manufacturing industry where n is small but also in service industry where n is moderate. In this paper, we introduce a new definition of control limits in the two most appreciated control charts in the literature, i.e., the improved generalized variance chart (IGV-chart) and vector variance chart (VV-chart). With the new definition of control limits, the reliability of the control charts can be determined. Some important properties of new control limits will be derived and the computational technique of probability of false alarm will be delivered.

  17. Design and Research of the Sewage Treatment Control System

    NASA Astrophysics Data System (ADS)

    Chu, J.; Hu, W. W.

    Due to the rapid development of China's economy, the water pollution has become a problem that we have to face. In particular, how to deal with industrial wastewater has become a top priority. In wastewater treatment, the control system based on PLC has met the design requirement in real-time, reliability, precision and so on. The integration of sequence control and process control in PLC, has the characteristics of high reliability, simple network, convenient and flexible use. PLC is a powerful tool for small and medium-sized industrial automation. Therefore, the sewage treatment control system take PLC as the core of control system, can nicely solve the problem of industrial wastewater in a certain extent.

  18. Extending the wavelength range in the Oclaro high-brightness broad area modules

    NASA Astrophysics Data System (ADS)

    Pawlik, Susanne; Guarino, Andrea; Sverdlov, Boris; Müller, Jürgen; Button, Christopher; Arlt, Sebastian; Jaeggi, Dominik; Lichtenstein, Norbert

    2010-02-01

    The demand for high power laser diode modules in the wavelength range between 793 nm and 1060 nm has been growing continuously over the last several years. Progress in eye-safe fiber lasers requires reliable pump power at 793 nm, modules at 808 nm are used for small size DPSSL applications and fiber-coupled laser sources at 830 nm are used in printing industry. However, power levels achieved in this wavelength range have remained lower than for the 9xx nm range. Here we report on approaches to increasing the reliable power in our latest generations of high power pump modules in the wavelength range between 793 nm and 1060 nm.

  19. Effect of bow-type initial imperfection on reliability of minimum-weight, stiffened structural panels

    NASA Technical Reports Server (NTRS)

    Stroud, W. Jefferson; Krishnamurthy, Thiagaraja; Sykes, Nancy P.; Elishakoff, Isaac

    1993-01-01

    Computations were performed to determine the effect of an overall bow-type imperfection on the reliability of structural panels under combined compression and shear loadings. A panel's reliability is the probability that it will perform the intended function - in this case, carry a given load without buckling or exceeding in-plane strain allowables. For a panel loaded in compression, a small initial bow can cause large bending stresses that reduce both the buckling load and the load at which strain allowables are exceeded; hence, the bow reduces the reliability of the panel. In this report, analytical studies on two stiffened panels quantified that effect. The bow is in the shape of a half-sine wave along the length of the panel. The size e of the bow at panel midlength is taken to be the single random variable. Several probability density distributions for e are examined to determine the sensitivity of the reliability to details of the bow statistics. In addition, the effects of quality control are explored with truncated distributions.

  20. Topological charge and cooling scales in pure SU(2) lattice gauge theory

    NASA Astrophysics Data System (ADS)

    Berg, Bernd A.; Clarke, David A.

    2018-03-01

    Using Monte Carlo simulations with overrelaxation, we have equilibrated lattices up to β =2.928 , size 6 04, for pure SU(2) lattice gauge theory with the Wilson action. We calculate topological charges with the standard cooling method and find that they become more reliable with increasing β values and lattice sizes. Continuum limit estimates of the topological susceptibility χ are obtained of which we favor χ1 /4/Tc=0.643 (12 ) , where Tc is the SU(2) deconfinement temperature. Differences between cooling length scales in different topological sectors turn out to be too small to be detectable within our statistical errors.

  1. Long-term patterns of body mass and stature evolution within the hominin lineage.

    PubMed

    Will, Manuel; Pablos, Adrián; Stock, Jay T

    2017-11-01

    Body size is a central determinant of a species' biology and adaptive strategy, but the number of reliable estimates of hominin body mass and stature have been insufficient to determine long-term patterns and subtle interactions in these size components within our lineage. Here, we analyse 254 body mass and 204 stature estimates from a total of 311 hominin specimens dating from 4.4 Ma to the Holocene using multi-level chronological and taxonomic analytical categories. The results demonstrate complex temporal patterns of body size variation with phases of relative stasis intermitted by periods of rapid increases. The observed trajectories could result from punctuated increases at speciation events, but also differential proliferation of large-bodied taxa or the extinction of small-bodied populations. Combined taxonomic and temporal analyses show that in relation to australopithecines, early Homo is characterized by significantly larger average body mass and stature but retains considerable diversity, including small body sizes. Within later Homo , stature and body mass evolution follow different trajectories: average modern stature is maintained from ca 1.6 Ma, while consistently higher body masses are not established until the Middle Pleistocene at ca 0.5-0.4 Ma, likely caused by directional selection related to colonizing higher latitudes. Selection against small-bodied individuals (less than 40 kg; less than 140 cm) after 1.4 Ma is associated with a decrease in relative size variability in later Homo species compared with earlier Homo and australopithecines. The isolated small-bodied individuals of Homo naledi ( ca 0.3 Ma) and Homo floresiensis ( ca 100-60 ka) constitute important exceptions to these general patterns, adding further layers of complexity to the evolution of body size within the genus Homo . At the end of the Late Pleistocene and Holocene, body size in Homo sapiens declines on average, but also extends to lower limits not seen in comparable frequency since early Homo .

  2. Long-term patterns of body mass and stature evolution within the hominin lineage

    PubMed Central

    Pablos, Adrián; Stock, Jay T.

    2017-01-01

    Body size is a central determinant of a species' biology and adaptive strategy, but the number of reliable estimates of hominin body mass and stature have been insufficient to determine long-term patterns and subtle interactions in these size components within our lineage. Here, we analyse 254 body mass and 204 stature estimates from a total of 311 hominin specimens dating from 4.4 Ma to the Holocene using multi-level chronological and taxonomic analytical categories. The results demonstrate complex temporal patterns of body size variation with phases of relative stasis intermitted by periods of rapid increases. The observed trajectories could result from punctuated increases at speciation events, but also differential proliferation of large-bodied taxa or the extinction of small-bodied populations. Combined taxonomic and temporal analyses show that in relation to australopithecines, early Homo is characterized by significantly larger average body mass and stature but retains considerable diversity, including small body sizes. Within later Homo, stature and body mass evolution follow different trajectories: average modern stature is maintained from ca 1.6 Ma, while consistently higher body masses are not established until the Middle Pleistocene at ca 0.5–0.4 Ma, likely caused by directional selection related to colonizing higher latitudes. Selection against small-bodied individuals (less than 40 kg; less than 140 cm) after 1.4 Ma is associated with a decrease in relative size variability in later Homo species compared with earlier Homo and australopithecines. The isolated small-bodied individuals of Homo naledi (ca 0.3 Ma) and Homo floresiensis (ca 100–60 ka) constitute important exceptions to these general patterns, adding further layers of complexity to the evolution of body size within the genus Homo. At the end of the Late Pleistocene and Holocene, body size in Homo sapiens declines on average, but also extends to lower limits not seen in comparable frequency since early Homo. PMID:29291118

  3. Small conductive particle sensor. [microfiber size determination

    NASA Technical Reports Server (NTRS)

    Taback, I. (Inventor)

    1981-01-01

    An electrostatic conductive fiber detector is disclosed for use in detecting, counting and measuring the length of fibers down to 0.1 mm and below with increased accuracy and reliability over prior art devices. It can be used for detection of fibers suspending in a flowing gas, in a nonflowing gas, or in a vacuum and its accumulated counts over a period of time is essentially unaffected by velocity of the fibers being detected.

  4. New approaches to trials in glomerulonephritis.

    PubMed

    Craig, Jonathan C; Tong, Allison; Strippoli, Giovanni F M

    2017-01-01

    Randomized controlled trials are required to reliably identify interventions to improve the outcomes for people with glomerulonephritis (GN). Unfortunately, although easier, observational studies are inherently unreliable even though the findings of both study designs agree most of the time. Currently there are ∼790 trials in GN, but suboptimal design and reporting, together with small sample sizes, mean that they may not be reliable for decision making. If the history is somewhat bleak, the future looks bright, with recent initiatives to improve the quality, size and relevance of clinical trials in nephrology, including greater patient engagement, trial networks, core outcome sets, registry-based trials and adaptive designs. Given the current state of the evidence informing the care of people with GN, disruptive technologies and pervasive culture change is required to ensure that the potential of trials to improve the health of people with this complex condition is to be realized. © The Author 2017. Published by Oxford University Press on behalf of ERA-EDTA. All rights reserved.

  5. Touch Precision Modulates Visual Bias.

    PubMed

    Misceo, Giovanni F; Jones, Maurice D

    2018-01-01

    The sensory precision hypothesis holds that different seen and felt cues about the size of an object resolve themselves in favor of the more reliable modality. To examine this precision hypothesis, 60 college students were asked to look at one size while manually exploring another unseen size either with their bare fingers or, to lessen the reliability of touch, with their fingers sleeved in rigid tubes. Afterwards, the participants estimated either the seen size or the felt size by finding a match from a visual display of various sizes. Results showed that the seen size biased the estimates of the felt size when the reliability of touch decreased. This finding supports the interaction between touch reliability and visual bias predicted by statistically optimal models of sensory integration.

  6. Reading comprehension and its underlying components in second-language learners: A meta-analysis of studies comparing first- and second-language learners.

    PubMed

    Melby-Lervåg, Monica; Lervåg, Arne

    2014-03-01

    We report a systematic meta-analytic review of studies comparing reading comprehension and its underlying components (language comprehension, decoding, and phonological awareness) in first- and second-language learners. The review included 82 studies, and 576 effect sizes were calculated for reading comprehension and underlying components. Key findings were that, compared to first-language learners, second-language learners display a medium-sized deficit in reading comprehension (pooled effect size d = -0.62), a large deficit in language comprehension (pooled effect size d = -1.12), but only small differences in phonological awareness (pooled effect size d = -0.08) and decoding (pooled effect size d = -0.12). A moderator analysis showed that characteristics related to the type of reading comprehension test reliably explained the variation in the differences in reading comprehension between first- and second-language learners. For language comprehension, studies of samples from low socioeconomic backgrounds and samples where only the first language was used at home generated the largest group differences in favor of first-language learners. Test characteristics and study origin reliably contributed to the variations between the studies of language comprehension. For decoding, Canadian studies showed group differences in favor of second-language learners, whereas the opposite was the case for U.S. studies. Regarding implications, unless specific decoding problems are detected, interventions that aim to ameliorate reading comprehension problems among second-language learners should focus on language comprehension skills.

  7. ACTS Propagation Measurements in Maryland and Virginia

    NASA Technical Reports Server (NTRS)

    Dissanayake, Asoka; Lin, Kuan-Ting

    1996-01-01

    Rapid growth in new satellite services incorporating very small aperture terminals (VSAT) and ultra small aperture terminals (USAT) is expected in the coming years. Small size terminals allow for widespread use of satellite services in small business and domestic applications. Due to congestion of lower frequency bands such as C and Ku, most of these services will use Ka-band (2/20 GHz) frequencies. Propagation impairments produced by the troposphere is a limiting factor for the effective use of the 20/30 GHz band and the use of smaller Earth terminals makes it difficult to provide sufficient link margins for propagation related outages. In this context, reliable prediction of propagation impairments for low margin systems becomes important. Due to the complexity of propagation phenomena propagation modeling is mainly attempted on an empirical basis. As such, the availability of reliable measured data that extend to probability levels well in excess of the traditional limit of 1 percent is of great importance in the development, validation, and refinement of propagation models. The beacon payload on the Advanced Communications Technology Satellite (ACTS) together with the propagation measurement terminals developed under the NASA ACTS propagation program provide an excellent opportunity to collect such data on a long-term basis. This paper presents the results of ACTS propagation measurements conducted in the Washington, DC metropolitan area by COMSAT Laboratories.

  8. High-power direct-diode laser successes

    NASA Astrophysics Data System (ADS)

    Haake, John M.; Zediker, Mark S.

    2004-06-01

    Direct diode laser will become much more prevalent in the solar system of manufacturing due to their high efficiency, small portable size, unique beam profiles, and low ownership costs. There has been many novel applications described for high power direct diode laser [HPDDL] systems but few have been implemented in extreme production environments due to diode and diode system reliability. We discuss several novel applications in which the HPDDL have been implemented and proven reliable and cost-effective in production environments. These applications are laser hardening/surface modification, laser wire feed welding and laser paint stripping. Each of these applications uniquely tests the direct diode laser systems capabilities and confirms their reliability in production environments. A comparison of the advantages direct diode laser versus traditional industrial lasers such as CO2 and Nd:YAG and non-laser technologies such a RF induction, and MIG welders for each of these production applications is presented.

  9. Identification of Small Exonic CNV from Whole-Exome Sequence Data and Application to Autism Spectrum Disorder

    PubMed Central

    Poultney, Christopher S.; Goldberg, Arthur P.; Drapeau, Elodie; Kou, Yan; Harony-Nicolas, Hala; Kajiwara, Yuji; De Rubeis, Silvia; Durand, Simon; Stevens, Christine; Rehnström, Karola; Palotie, Aarno; Daly, Mark J.; Ma’ayan, Avi; Fromer, Menachem; Buxbaum, Joseph D.

    2013-01-01

    Copy number variation (CNV) is an important determinant of human diversity and plays important roles in susceptibility to disease. Most studies of CNV carried out to date have made use of chromosome microarray and have had a lower size limit for detection of about 30 kilobases (kb). With the emergence of whole-exome sequencing studies, we asked whether such data could be used to reliably call rare exonic CNV in the size range of 1–30 kilobases (kb), making use of the eXome Hidden Markov Model (XHMM) program. By using both transmission information and validation by molecular methods, we confirmed that small CNV encompassing as few as three exons can be reliably called from whole-exome data. We applied this approach to an autism case-control sample (n = 811, mean per-target read depth = 161) and observed a significant increase in the burden of rare (MAF ≤1%) 1–30 kb CNV, 1–30 kb deletions, and 1–10 kb deletions in ASD. CNV in the 1–30 kb range frequently hit just a single gene, and we were therefore able to carry out enrichment and pathway analyses, where we observed enrichment for disruption of genes in cytoskeletal and autophagy pathways in ASD. In summary, our results showed that XHMM provided an effective means to assess small exonic CNV from whole-exome data, indicated that rare 1–30 kb exonic deletions could contribute to risk in up to 7% of individuals with ASD, and implicated a candidate pathway in developmental delay syndromes. PMID:24094742

  10. Effect of Compressive Stresses on Leakage Currents in Microchip Tantalum Capacitors

    NASA Technical Reports Server (NTRS)

    Teverovsky, Alexander

    2012-01-01

    Microchip tantalum capacitors are manufactured using new technologies that allow for production of small size capacitors (down to EIA case size 0402) with volumetric efficiency much greater than for regular chip capacitors. Due to a small size of the parts and leadless design they might be more sensitive to mechanical stresses that develop after soldering onto printed wiring boards (PWB) compared to standard chip capacitors. In this work, the effect of compressive stresses on leakage currents in capacitors has been investigated in the range of stresses up to 200 MPa. Significant, up to three orders of magnitude, variations of currents were observed after the stress exceeds a certain critical level that varied from 10 MPa to 180 MPa for capacitors used in this study. A stress-induced generation of electron traps in tantalum pentoxide dielectric is suggested to explain reversible variations of leakage currents in tantalum capacitors. Thermo-mechanical characteristics of microchip capacitors have been studied to estimate the level of stresses caused by assembly onto PWB and assess the risk of stress-related degradation and failures. Keywords: tantalum capacitors, leakage current, soldering, reliability, mechanical stress.

  11. High volcanic seismic b-values: Real or artefacts?

    NASA Astrophysics Data System (ADS)

    Roberts, Nick; Bell, Andrew; Main, Ian G.

    2015-04-01

    The b-value of the Gutenberg-Richter distribution quantifies the relative proportion of large to small magnitude earthquakes in a catalogue, in turn related to the population of fault rupture areas and the average slip or stress drop. Accordingly the b-value is an important parameter to consider when evaluating seismic catalogues as it has the potential to provide insight into the temporal or spatial evolution of the system, such as fracture development or changes in the local stress regime. The b-value for tectonic seismicity is commonly found to be close to 1, whereas much higher b-values are frequently reported for volcanic and induced seismicity. Understanding these differences is important for understanding the processes controlling earthquake occurrence in different settings. However, it is possible that anomalously high b-values could arise from small sample sizes, under-estimated completeness magnitudes, or other poorly applied methodologies. Therefore, it is important to establish a rigorous workflow for analyzing these datasets. Here we examine the frequency-magnitude distributions of volcanic earthquake catalogues in order to determine the significance of apparently high b-values. We first derive a workflow for computing the completeness magnitude of a seismic catalogue, using synthetic catalogues of varying shape, size, and known b-value. We find the best approach involves a combination of three methods: 'Maximum Curvature', 'b-value stability', and the 'Goodness-of-Fit test'. To calculate a reliable b-value with an error ≤0.25, the maximum curvature method is preferred for a 'sharp-peaked' discrete distribution. For a catalogue with a broader peak the b-value stability method is the most reliable with the Goodness-of-Fit test being an acceptable backup if the b-value stability method fails. We apply this workflow to earthquake catalogues from El Hierro (2011-2013) and Mt Etna (1999-2013) volcanoes. In general, we find the b-value to be equal to or slightly greater than 1. However, reliable high b-values of 1.5-2.4 at El Hierro and 1.5-1.8 at Mt Etna are observed for restricted time periods. We argue that many of the almost axiomatically 'high' b-values reported in the literature for volcanic and induced seismicity may be attributable to biases introduced by the methods of inference used and/or the relatively small sample sizes often available.

  12. Can high seismic b-values be explained solely by poorly applied methodology?

    NASA Astrophysics Data System (ADS)

    Roberts, Nick; Bell, Andrew; Main, Ian

    2015-04-01

    The b-value of the Gutenberg-Richter distribution quantifies the relative proportion of large to small magnitude earthquakes in a catalogue, in turn related to the population of fault rupture areas and the average slip or stress drop. Accordingly the b-value is an important parameter to consider when evaluating seismic catalogues as it has the potential to provide insight into the temporal or spatial evolution of the system, such as fracture development or changes in the local stress regime. The b-value for tectonic seismicity is commonly found to be close to 1, whereas much higher b-values are frequently reported for volcanic and induced seismicity. Understanding these differences is important for understanding the processes controlling earthquake occurrence in different settings. However, it is possible that anomalously high b-values could arise from small sample sizes, under-estimated completeness magnitudes, or other poorly applied methodologies. Therefore, it is important to establish a rigorous workflow for analyzing these datasets. Here we examine the frequency-magnitude distributions of volcanic earthquake catalogues in order to determine the significance of apparently high b-values. We first derive a workflow for computing the completeness magnitude of a seismic catalogue, using synthetic catalogues of varying shape, size, and known b-value. We find the best approach involves a combination of three methods: 'Maximum Curvature', 'b-value stability', and the 'Goodness-of-Fit test'. To calculate a reliable b-value with an error ≤0.25, the maximum curvature method is preferred for a 'sharp-peaked' discrete distribution. For a catalogue with a broader peak the b-value stability method is the most reliable with the Goodness-of-Fit test being an acceptable backup if the b-value stability method fails. We apply this workflow to earthquake catalogues from El Hierro (2011-2013) and Mt Etna (1999-2013) volcanoes. In general, we find the b-value to be equal to or slightly greater than 1, however, reliably high b-values are reported in both catalogues. We argue that many of the almost axiomatically 'high' b-values reported in the literature for volcanic and induced seismicity may be attributable to biases introduced by the methods of inference used and/or the relatively small sample sizes often available. This new methodology, although focused towards volcanic catalogues, is applicabale to all seismic catalogues.

  13. Infrapopulations of Gyliauchen volubilis Nagaty, 1956 (Trematoda: Gyliauchenidae) in the rabbitfish Siganus rivulatus (Teleostei: Siganidae) from the Saudi coast of the Red Sea.

    PubMed

    Al-Jahdali, M O

    2012-08-01

    In hermaphroditic helminth parasites, infrapopulation size or mating group size mostly affects some processes acting within the infrapopulation. Here, 30 natural infrapopulations (12-154 individuals) of the intestinal trematode Gyliauchen volubilis Nagaty, 1956 from the fish Siganus rivulatus consisting of newly excysted juveniles, immature and mature worms were found distributed in a well-defined fundamental niche (anterior 40% of the intestine). In small infrapopulations, all stages of the parasite were alive. In larger infrapopulations, differential mortality was only and consistently observed among newly excysted juveniles, and gradually increased to include most or all juveniles in the largest infrapopulations. Among mature worms, the mean worm length seemed unaffected by the infrapopulation size. However, the ratio mean testis size-mean ovary size, a reliable indicator of resource allocation to the male function and of opportunities for cross fertilization, significantly increased with mating group size. In small infrapopulations, all stages of the parasite were scattered along the niche, and never seen in mating pairs (possibly reproduced by self-fertilization). In larger infrapopulations, newly excysted juveniles and immature worms were scattered along the anterior two thirds of the niche, while mature worms were constantly found aggregated in its posterior third (narrow microhabitat), where some were arranged in mating pairs. The probability of mating reciprocally or unilaterally was dependent on body size. The mean number of uterine eggs per worm significantly decreased and their mean sizes significantly increased with mating group size. The results are statistically significant and suggest that infrapopulation self-regulation is greatly associated with its size.

  14. Chairside CAD/CAM materials. Part 2: Flexural strength testing.

    PubMed

    Wendler, Michael; Belli, Renan; Petschelt, Anselm; Mevec, Daniel; Harrer, Walter; Lube, Tanja; Danzer, Robert; Lohbauer, Ulrich

    2017-01-01

    Strength is one of the preferred parameters used in dentistry for determining clinical indication of dental restoratives. However, small dimensions of CAD/CAM blocks limit reliable measurements with standardized uniaxial bending tests. The objective of this study was to introduce the ball-on-three-ball (B3B) biaxial strength test for dental for small CAD/CAM block in the context of the size effect on strength predicted by the Weibull theory. Eight representative chairside CAD/CAM materials ranging from polycrystalline zirconia (e.max ZirCAD, Ivoclar-Vivadent), reinforced glasses (Vitablocs Mark II, VITA; Empress CAD, Ivoclar-Vivadent) and glass-ceramics (e.max CAD, Ivoclar-Vivadent; Suprinity, VITA; Celtra Duo, Dentsply) to hybrid materials (Enamic, VITA; Lava Ultimate, 3M ESPE) have been selected. Specimens were prepared with highly polished surfaces in rectangular plate (12×12×1.2mm 3 ) or round disc (Ø=12mm, thickness=1.2mm) geometries. Specimens were tested using the B3B assembly and the biaxial strength was determined using calculations derived from finite element analyses of the respective stress fields. Size effects on strength were determined based on results from 4-point-bending specimens. A good agreement was found between the biaxial strength results for the different geometries (plates vs. discs) using the B3B test. Strength values ranged from 110.9MPa (Vitablocs Mark II) to 1303.21MPa (e.max ZirCAD). The strength dependency on specimen size was demonstrated through the calculated effective volume/surface. The B3B test has shown to be a reliable and simple method for determining the biaxial strength restorative materials supplied as small CAD/CAM blocks. A flexible solution was made available for the B3B test in the rectangular plate geometry. Copyright © 2016 The Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  15. SmallSat Innovations for Planetary Science

    NASA Astrophysics Data System (ADS)

    Weinberg, Jonathan; Petroy, Shelley; Roark, Shane; Schindhelm, Eric

    2017-10-01

    As NASA continues to look for ways to fly smaller planetary missions such as SIMPLEX, MoO, and Venus Bridge, it is important that spacecraft and instrument capabilities keep pace to allow these missions to move forward. As spacecraft become smaller, it is necessary to balance size with capability, reliability and payload capacity. Ball Aerospace offers extensive SmallSat capabilities matured over the past decade, utilizing our broad experience developing mission architecture, assembling spacecraft and instruments, and testing advanced enabling technologies. Ball SmallSats inherit their software capabilities from the flight proven Ball Configurable Platform (BCP) line of spacecraft, and may be tailored to meet the unique requirements of Planetary Science missions. We present here recent efforts in pioneering both instrument miniaturization and SmallSat/sensorcraft development through mission design and implementation. Ball has flown several missions with small, but capable spacecraft. We also have demonstrated a variety of enhanced spacecraft/instrument capabilities in the laboratory and in flight to advance autonomy in spaceflight hardware that can enable some small planetary missions.

  16. Small sample sizes in the study of ontogenetic allometry; implications for palaeobiology

    PubMed Central

    Vavrek, Matthew J.

    2015-01-01

    Quantitative morphometric analyses, particularly ontogenetic allometry, are common methods used in quantifying shape, and changes therein, in both extinct and extant organisms. Due to incompleteness and the potential for restricted sample sizes in the fossil record, palaeobiological analyses of allometry may encounter higher rates of error. Differences in sample size between fossil and extant studies and any resulting effects on allometric analyses have not been thoroughly investigated, and a logical lower threshold to sample size is not clear. Here we show that studies based on fossil datasets have smaller sample sizes than those based on extant taxa. A similar pattern between vertebrates and invertebrates indicates this is not a problem unique to either group, but common to both. We investigate the relationship between sample size, ontogenetic allometric relationship and statistical power using an empirical dataset of skull measurements of modern Alligator mississippiensis. Across a variety of subsampling techniques, used to simulate different taphonomic and/or sampling effects, smaller sample sizes gave less reliable and more variable results, often with the result that allometric relationships will go undetected due to Type II error (failure to reject the null hypothesis). This may result in a false impression of fewer instances of positive/negative allometric growth in fossils compared to living organisms. These limitations are not restricted to fossil data and are equally applicable to allometric analyses of rare extant taxa. No mathematically derived minimum sample size for ontogenetic allometric studies is found; rather results of isometry (but not necessarily allometry) should not be viewed with confidence at small sample sizes. PMID:25780770

  17. Microreactor System Design for a NASA In Situ Propellant Production Plant on Mars

    NASA Technical Reports Server (NTRS)

    TeGrotenhuis, W. E.; Wegeng, R. S.; Vanderwiel, D. P.; Whyatt, G. A.; Viswanathan, V. V.; Schielke, K. P.; Sanders, G. B.; Peters, T. A.; Nicholson, Leonard S. (Technical Monitor)

    2000-01-01

    The NASA In Situ Resource Utilization (ISRU) program is planning near-term missions to Mars that will include chemical processes for converting the carbon dioxide (CO2) and possibly water from the Martian environment to propellants, oxygen, and other useful chemicals. The use of indigenous resources reduces the size and weight of the payloads from Earth significantly, representing enormous cost savings that make human exploration of Mars affordable. Extraterrestrial chemical processing plants will need to be compact, lightweight, highly efficient under reduced gravity, and extraordinarily reliable for long periods. Microchemical and thermal systems represent capability for dramatic reduction in size and weight, while offering high reliability through massive parallelization. In situ propellant production (ISPP), one aspect of the ISRU program, involves collecting and pressurizing atmospheric CO2, conversion reactions, chemical separations, heat exchangers, and cryogenic storage. A preliminary system design of an ISPP plant based on microtechnology has demonstrated significant size, weight, and energy efficiency gains over the current NASA baseline. Energy management is a strong driver for Mars-based processes, not only because energy is a scarce resource, but because heat rejection is problematic; the low pressure environment makes convective heat transfer ineffective. Energy efficiency gains are largely achieved in the microchemical plant through extensive heat recuperation and energy cascading, which has a small size and weight penalty because the added micro heat exchangers are small. This leads to additional size and weight gains by reducing the required area of waste heat radiators. The microtechnology-based ISPP plant is described in detail, including aspects of pinch analysis for optimizing the heat exchanger network. Three options for thermochemical compression Of CO2 from the Martian atmosphere, adsorption, absorption, and cryogenic freezing, are presented, as well as three options for water decomposition, low temperature electrolysis, high temperature electrolysis, and thermochemical decomposition. Other elements of the plant include Sabatier and reverse water gas shift reactors, water recovery, chemical separations, and cryogenic storage. Data are presented supporting preliminary sizing of components, and results of the system design are compared to the existing NASA baseline that is based on conventional technologies.

  18. Research on pre-processing of QR Code

    NASA Astrophysics Data System (ADS)

    Sun, Haixing; Xia, Haojie; Dong, Ning

    2013-10-01

    QR code encodes many kinds of information because of its advantages: large storage capacity, high reliability, full arrange of utter-high-speed reading, small printing size and high-efficient representation of Chinese characters, etc. In order to obtain the clearer binarization image from complex background, and improve the recognition rate of QR code, this paper researches on pre-processing methods of QR code (Quick Response Code), and shows algorithms and results of image pre-processing for QR code recognition. Improve the conventional method by changing the Souvola's adaptive text recognition method. Additionally, introduce the QR code Extraction which adapts to different image size, flexible image correction approach, and improve the efficiency and accuracy of QR code image processing.

  19. Pairwise Maximum Entropy Models for Studying Large Biological Systems: When They Can Work and When They Can't

    PubMed Central

    Roudi, Yasser; Nirenberg, Sheila; Latham, Peter E.

    2009-01-01

    One of the most critical problems we face in the study of biological systems is building accurate statistical descriptions of them. This problem has been particularly challenging because biological systems typically contain large numbers of interacting elements, which precludes the use of standard brute force approaches. Recently, though, several groups have reported that there may be an alternate strategy. The reports show that reliable statistical models can be built without knowledge of all the interactions in a system; instead, pairwise interactions can suffice. These findings, however, are based on the analysis of small subsystems. Here, we ask whether the observations will generalize to systems of realistic size, that is, whether pairwise models will provide reliable descriptions of true biological systems. Our results show that, in most cases, they will not. The reason is that there is a crossover in the predictive power of pairwise models: If the size of the subsystem is below the crossover point, then the results have no predictive power for large systems. If the size is above the crossover point, then the results may have predictive power. This work thus provides a general framework for determining the extent to which pairwise models can be used to predict the behavior of large biological systems. Applied to neural data, the size of most systems studied so far is below the crossover point. PMID:19424487

  20. The sizing of hamstring grafts for anterior cruciate reconstruction: intra- and inter-observer reliability.

    PubMed

    Dwyer, Tim; Whelan, Daniel B; Khoshbin, Amir; Wasserstein, David; Dold, Andrew; Chahal, Jaskarndip; Nauth, Aaron; Murnaghan, M Lucas; Ogilvie-Harris, Darrell J; Theodoropoulos, John S

    2015-04-01

    The objective of this study was to establish the intra- and inter-observer reliability of hamstring graft measurement using cylindrical sizing tubes. Hamstring tendons (gracilis and semitendinosus) were harvested from ten cadavers by a single surgeon and whip stitched together to create ten 4-strand hamstring grafts. Ten sports medicine surgeons and fellows sized each graft independently using either hollow cylindrical sizers or block sizers in 0.5-mm increments—the sizing technique used was applied consistently to each graft. Surgeons moved sequentially from graft to graft and measured each hamstring graft twice. Surgeons were asked to state the measured proximal (femoral) and distal (tibial) diameter of each graft, as well as the diameter of the tibial and femoral tunnels that they would drill if performing an anterior cruciate ligament (ACL) reconstruction using that graft. Reliability was established using intra-class correlation coefficients. Overall, both the inter-observer and intra-observer agreement were >0.9, demonstrating excellent reliability. The inter-observer reliability for drill sizes was also excellent (>0.9). Excellent correlation was seen between cylindrical sizing, and drill sizes (>0.9). Sizing of hamstring grafts by multiple surgeons demonstrated excellent intra-observer and intra-observer reliability, potentially validating clinical studies exploring ACL reconstruction outcomes by hamstring graft diameter when standard techniques are used. III.

  1. Solid State Inflation Balloon Active Deorbiter: Scalable Low-Cost Deorbit System for Small Satellites

    NASA Technical Reports Server (NTRS)

    Huang, Adam

    2016-01-01

    The goal of the Solid State Inflation Balloon Active Deorbiter project is to develop and demonstrate a scalable, simple, reliable, and low-cost active deorbiting system capable of controlling the downrange point of impact for the full-range of small satellites from 1 kg to 180 kg. The key enabling technology being developed is the Solid State Gas Generator (SSGG) chip, generating pure nitrogen gas from sodium azide (NaN3) micro-crystals. Coupled with a metalized nonelastic drag balloon, the complete Solid State Inflation Balloon (SSIB) system is capable of repeated inflation/deflation cycles. The SSGG minimizes size, weight, electrical power, and cost when compared to the current state of the art.

  2. Sizing protein-templated gold nanoclusters by time resolved fluorescence anisotropy decay measurements

    NASA Astrophysics Data System (ADS)

    Soleilhac, Antonin; Bertorelle, Franck; Antoine, Rodolphe

    2018-03-01

    Protein-templated gold nanoclusters (AuNCs) are very attractive due to their unique fluorescence properties. A major problem however may arise due to protein structure changes upon the nucleation of an AuNC within the protein for any future use as in vivo probes, for instance. In this work, we propose a simple and reliable fluorescence based technique measuring the hydrodynamic size of protein-templated gold nanoclusters. This technique uses the relation between the time resolved fluorescence anisotropy decay and the hydrodynamic volume, through the rotational correlation time. We determine the molecular size of protein-directed AuNCs, with protein templates of increasing sizes, e.g. insulin, lysozyme, and bovine serum albumin (BSA). The comparison of sizes obtained by other techniques (e.g. dynamic light scattering and small-angle X-ray scattering) between bare and gold clusters containing proteins allows us to address the volume changes induced either by conformational changes (for BSA) or the formation of protein dimers (for insulin and lysozyme) during cluster formation and incorporation.

  3. Design and characterization of very high frequency pulse tube prototypes

    NASA Astrophysics Data System (ADS)

    Lopes, Diogo; Duval, Jean-Marc; Charles, Ivan; Butterworth, James; Trollier, Thierry; Tanchon, Julien; Ravex, Alain; Daniel, Christophe

    2012-06-01

    Weight and size are important features of a cryocooler when it comes to space applications. Given their reliability and low level of exported vibrations (due to the absence of moving cold parts), pulse tubes are good candidates for spatial purposes and their miniaturization has been the focus of many studies. We report on the design and performance of a small-scale very high frequency pulse tube prototype, modeled after two previous prototypes which were optimized with a numerical code.

  4. Common/Dependent-Pressure-Vessel Nickel-Hydrogen Batteries

    NASA Technical Reports Server (NTRS)

    Timmerman, Paul J.

    2003-01-01

    The term "common/dependent pressure vessel" (C/DPV) denotes a proposed alternative configuration for a nickelhydrogen battery. The C/DPV configuration is so named because it is a hybrid of two prior configurations called "common pressure vessel" (CPV) and "dependent pressure vessel" (DPV). The C/DPV configuration has been proposed as a basis for designing highly reliable, long-life Ni/H2-batteries and cells for anticipated special applications in which it is expected that small charge capacities will suffice and sizes and weights must be minimized.

  5. Use of portable antennas to estimate abundance of PIT-tagged fish in small streams: Factors affecting detection probability

    USGS Publications Warehouse

    O'Donnell, Matthew J.; Horton, Gregg E.; Letcher, Benjamin H.

    2010-01-01

    Portable passive integrated transponder (PIT) tag antenna systems can be valuable in providing reliable estimates of the abundance of tagged Atlantic salmon Salmo salar in small streams under a wide range of conditions. We developed and employed PIT tag antenna wand techniques in two controlled experiments and an additional case study to examine the factors that influenced our ability to estimate population size. We used Pollock's robust-design capture–mark–recapture model to obtain estimates of the probability of first detection (p), the probability of redetection (c), and abundance (N) in the two controlled experiments. First, we conducted an experiment in which tags were hidden in fixed locations. Although p and c varied among the three observers and among the three passes that each observer conducted, the estimates of N were identical to the true values and did not vary among observers. In the second experiment using free-swimming tagged fish, p and c varied among passes and time of day. Additionally, estimates of N varied between day and night and among age-classes but were within 10% of the true population size. In the case study, we used the Cormack–Jolly–Seber model to examine the variation in p, and we compared counts of tagged fish found with the antenna wand with counts collected via electrofishing. In that study, we found that although p varied for age-classes, sample dates, and time of day, antenna and electrofishing estimates of N were similar, indicating that population size can be reliably estimated via PIT tag antenna wands. However, factors such as the observer, time of day, age of fish, and stream discharge can influence the initial and subsequent detection probabilities.

  6. Prognostics-based qualification of high-power white LEDs using Lévy process approach

    NASA Astrophysics Data System (ADS)

    Yung, Kam-Chuen; Sun, Bo; Jiang, Xiaopeng

    2017-01-01

    Due to their versatility in a variety of applications and the growing market demand, high-power white light-emitting diodes (LEDs) have attracted considerable attention. Reliability qualification testing is an essential part of the product development process to ensure the reliability of a new LED product before its release. However, the widely used IES-TM-21 method does not provide comprehensive reliability information. For more accurate and effective qualification, this paper presents a novel method based on prognostics techniques. Prognostics is an engineering technology predicting the future reliability or determining the remaining useful lifetime (RUL) of a product by assessing the extent of deviation or degradation from its expected normal operating conditions. A Lévy subordinator of a mixed Gamma and compound Poisson process is used to describe the actual degradation process of LEDs characterized by random sporadic small jumps of degradation degree, and the reliability function is derived for qualification with different distribution forms of jump sizes. The IES LM-80 test results reported by different LED vendors are used to develop and validate the qualification methodology. This study will be helpful for LED manufacturers to reduce the total test time and cost required to qualify the reliability of an LED product.

  7. Identification of small exonic CNV from whole-exome sequence data and application to autism spectrum disorder.

    PubMed

    Poultney, Christopher S; Goldberg, Arthur P; Drapeau, Elodie; Kou, Yan; Harony-Nicolas, Hala; Kajiwara, Yuji; De Rubeis, Silvia; Durand, Simon; Stevens, Christine; Rehnström, Karola; Palotie, Aarno; Daly, Mark J; Ma'ayan, Avi; Fromer, Menachem; Buxbaum, Joseph D

    2013-10-03

    Copy number variation (CNV) is an important determinant of human diversity and plays important roles in susceptibility to disease. Most studies of CNV carried out to date have made use of chromosome microarray and have had a lower size limit for detection of about 30 kilobases (kb). With the emergence of whole-exome sequencing studies, we asked whether such data could be used to reliably call rare exonic CNV in the size range of 1-30 kilobases (kb), making use of the eXome Hidden Markov Model (XHMM) program. By using both transmission information and validation by molecular methods, we confirmed that small CNV encompassing as few as three exons can be reliably called from whole-exome data. We applied this approach to an autism case-control sample (n = 811, mean per-target read depth = 161) and observed a significant increase in the burden of rare (MAF ≤1%) 1-30 kb CNV, 1-30 kb deletions, and 1-10 kb deletions in ASD. CNV in the 1-30 kb range frequently hit just a single gene, and we were therefore able to carry out enrichment and pathway analyses, where we observed enrichment for disruption of genes in cytoskeletal and autophagy pathways in ASD. In summary, our results showed that XHMM provided an effective means to assess small exonic CNV from whole-exome data, indicated that rare 1-30 kb exonic deletions could contribute to risk in up to 7% of individuals with ASD, and implicated a candidate pathway in developmental delay syndromes. Copyright © 2013 The American Society of Human Genetics. Published by Elsevier Inc. All rights reserved.

  8. Reliability of dose volume constraint inference from clinical data.

    PubMed

    Lutz, C M; Møller, D S; Hoffmann, L; Knap, M M; Alber, M

    2017-04-21

    Dose volume histogram points (DVHPs) frequently serve as dose constraints in radiotherapy treatment planning. An experiment was designed to investigate the reliability of DVHP inference from clinical data for multiple cohort sizes and complication incidence rates. The experimental background was radiation pneumonitis in non-small cell lung cancer and the DVHP inference method was based on logistic regression. From 102 NSCLC real-life dose distributions and a postulated DVHP model, an 'ideal' cohort was generated where the most predictive model was equal to the postulated model. A bootstrap and a Cohort Replication Monte Carlo (CoRepMC) approach were applied to create 1000 equally sized populations each. The cohorts were then analyzed to establish inference frequency distributions. This was applied to nine scenarios for cohort sizes of 102 (1), 500 (2) to 2000 (3) patients (by sampling with replacement) and three postulated DVHP models. The Bootstrap was repeated for a 'non-ideal' cohort, where the most predictive model did not coincide with the postulated model. The Bootstrap produced chaotic results for all models of cohort size 1 for both the ideal and non-ideal cohorts. For cohort size 2 and 3, the distributions for all populations were more concentrated around the postulated DVHP. For the CoRepMC, the inference frequency increased with cohort size and incidence rate. Correct inference rates  >[Formula: see text] were only achieved by cohorts with more than 500 patients. Both Bootstrap and CoRepMC indicate that inference of the correct or approximate DVHP for typical cohort sizes is highly uncertain. CoRepMC results were less spurious than Bootstrap results, demonstrating the large influence that randomness in dose-response has on the statistical analysis.

  9. Magnetic permeability as a predictor of the artefact size caused by orthodontic appliances at 1.5 T magnetic resonance imaging.

    PubMed

    Blankenstein, Felix H; Asbach, Patrick; Beuer, Florian; Glienke, Johannes; Mayer, Stefan; Zachriat, Christine

    2017-01-01

    Artefacts caused by orthodontic attachments limit the diagnostic value and lead to removal of these appliances before magnetic resonance imaging. Magnetic permeability can predict the artefact size. There is no standardised approach to determine the permeability of such attachments. The aim was to establish a reliable approach to determine artefact size caused by orthodontic attachments at 1.5 T MRI. Artefact radii of 21 attachments were determined applying two prevalent sequences of the head and neck region (turbo spin echo and gradient echo). The instrument Ferromaster (Stefan Mayer Instruments, Dinslaken) is approved for permeability measurements of objects with a minimum size (d = 20 mm, h = 5 mm). Eleven small test specimens of known permeability between 1.003 and 1.431 were produced. They are slightly larger than the orthodontic attachments. Their artefacts were measured and cross tabulated against the permeability. The resulting curve was used to compare the orthodontic attachments with the test bodies. Steel caused a wide range of artefact size of 10-74 mm subject to their permeability. Titanium, cobalt-chromium and ceramic materials produced artefact radii up to 20 mm. Measurement of artefacts of the test bodies revealed an interrelationship according to a root function. The artefact size of all brackets was below that root function. The permeability can be reliably assessed by conventional measurement devices and the artefact size can be predicted. The radiologist is able to decide whether or not the orthodontic attachments should be removed. This study clarifies whether an orthodontic appliance must be removed before taking an MRI.

  10. Reliability of dose volume constraint inference from clinical data

    NASA Astrophysics Data System (ADS)

    Lutz, C. M.; Møller, D. S.; Hoffmann, L.; Knap, M. M.; Alber, M.

    2017-04-01

    Dose volume histogram points (DVHPs) frequently serve as dose constraints in radiotherapy treatment planning. An experiment was designed to investigate the reliability of DVHP inference from clinical data for multiple cohort sizes and complication incidence rates. The experimental background was radiation pneumonitis in non-small cell lung cancer and the DVHP inference method was based on logistic regression. From 102 NSCLC real-life dose distributions and a postulated DVHP model, an ‘ideal’ cohort was generated where the most predictive model was equal to the postulated model. A bootstrap and a Cohort Replication Monte Carlo (CoRepMC) approach were applied to create 1000 equally sized populations each. The cohorts were then analyzed to establish inference frequency distributions. This was applied to nine scenarios for cohort sizes of 102 (1), 500 (2) to 2000 (3) patients (by sampling with replacement) and three postulated DVHP models. The Bootstrap was repeated for a ‘non-ideal’ cohort, where the most predictive model did not coincide with the postulated model. The Bootstrap produced chaotic results for all models of cohort size 1 for both the ideal and non-ideal cohorts. For cohort size 2 and 3, the distributions for all populations were more concentrated around the postulated DVHP. For the CoRepMC, the inference frequency increased with cohort size and incidence rate. Correct inference rates  >85 % were only achieved by cohorts with more than 500 patients. Both Bootstrap and CoRepMC indicate that inference of the correct or approximate DVHP for typical cohort sizes is highly uncertain. CoRepMC results were less spurious than Bootstrap results, demonstrating the large influence that randomness in dose-response has on the statistical analysis.

  11. Non-destructive evaluation of nano-sized structure of thin film devices by using small angle neutron scattering.

    PubMed

    Shin, E J; Seong, B S; Choi, Y; Lee, J K

    2011-01-01

    Nano-sized multi-layers copper-doped SrZrO3, platinum (Pt) and silicon oxide (SiO2) on silicon substrates were prepared by dense plasma focus (DPF) device with the high purity copper anode tip and analyzed by using small angle neutron scattering (SANS) to establish a reliable method for the non-destructive evaluation of the under-layer structure. Thin film was well formed at the time-to-dip of 5 microsec with stable plasma of DPF. Several smooth intensity peaks were periodically observed when neutron beam penetrates the thin film with multi-layers perpendicularly. The platinum layer is dominant to intensity peaks, where the copper-doped SrZnO3 layer next to the platinum layer causes peak broadening. The silicon oxide layer has less effect on the SANS spectra due to its relative thick thickness. The SANS spectra shows thicknesses of platinum and copper-doped SrZnO3 layers as 53 and 25 nm, respectively, which are well agreement with microstructure observation.

  12. Pneumothorax size measurements on digital chest radiographs: Intra- and inter- rater reliability.

    PubMed

    Thelle, Andreas; Gjerdevik, Miriam; Grydeland, Thomas; Skorge, Trude D; Wentzel-Larsen, Tore; Bakke, Per S

    2015-10-01

    Detailed and reliable methods may be important for discussions on the importance of pneumothorax size in clinical decision-making. Rhea's method is widely used to estimate pneumothorax size in percent based on chest X-rays (CXRs) from three measure points. Choi's addendum is used for anterioposterior projections. The aim of this study was to examine the intrarater and interrater reliability of the Rhea and Choi method using digital CXR in the ward based PACS monitors. Three physicians examined a retrospective series of 80 digital CXRs showing pneumothorax, using Rhea and Choi's method, then repeated in a random order two weeks later. We used the analysis of variance technique by Eliasziw et al. to assess the intrarater and interrater reliability in altogether 480 estimations of pneumothorax size. Estimated pneumothorax sizes ranged between 5% and 100%. The intrarater reliability coefficient was 0.98 (95% one-sided lower-limit confidence interval C 0.96), and the interrater reliability coefficient was 0.95 (95% one-sided lower-limit confidence interval 0.93). This study has shown that the Rhea and Choi method for calculating pneumothorax size has high intrarater and interrater reliability. These results are valid across gender, side of pneumothorax and whether the patient is diagnosed with primary or secondary pneumothorax. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  13. Validity and Reliability of the Chronic Respiratory Disease Questionnaire in Elderly Individuals with Mild to Moderate Non-Cystic Fibrosis Bronchiectasis.

    PubMed

    Vodanovich, Domagoj A; Bicknell, Thomas J; Holland, Anne E; Hill, Catherine J; Cecins, Nola; Jenkins, Sue; McDonald, Christine F; Burge, Angela T; Thompson, Philip; Stirling, Robert G; Lee, Annemarie L

    2015-01-01

    The chronic respiratory disease questionnaire (CRDQ) is designed to assess health-related quality of life (HRQOL) in chronic respiratory conditions, but its reliability, validity and responsiveness in individuals with mild to moderate non-cystic fibrosis (CF) bronchiectasis are unclear. This study aimed to determine measurement properties of the CRDQ in non-CF bronchiectasis. Participants with non-CF bronchiectasis involved in a randomised controlled trial of exercise training were recruited. Internal consistency was assessed using Cronbach's α. Over 8 weeks, reliability was evaluated using intra-class correlation coefficients and Bland-Altman analysis for measures of agreement. Convergent and divergent validity was assessed by correlations with the other HRQOL questionnaires and the Hospital Anxiety and Depression Scale (HADS). The responsiveness to exercise training was assessed using effect sizes and standardised response means. Eighty-five participants were included (mean age ± SD, 64 ± 13 years). Internal consistency was adequate (>0.7) for all CRDQ domains and the total score. Test-retest reliability ranged from 0.69 to 0.85 for each CRDQ domain and was 0.82 for the total score. Dyspnoea (CRDQ) was related to St George's respiratory questionnaire (SGRQ) symptoms only (r = 0.38), with no relationship to the Leicester cough questionnaire (LCQ) or HADS. Moderate correlations were found between the total score of the CRDQ, the SGRQ (rs = -0.49) and the LCQ score (rs = 0.51). Lower CRDQ scores were associated with higher anxiety and depression (rs = -0.46 to -0.56). The responsiveness of the CRDQ was small (effect size 0.1-0.24). The CRDQ is a valid and reliable measure of HRQOL in mild to moderate non-CF bronchiectasis, but responsiveness was limited. © 2015 S. Karger AG, Basel.

  14. A microfluidic platform for precision small-volume sample processing and its use to size separate biological particles with an acoustic microdevice [Precision size separation of biological particles in small-volume samples by an acoustic microfluidic system

    DOE PAGES

    Fong, Erika J.; Huang, Chao; Hamilton, Julie; ...

    2015-11-23

    Here, a major advantage of microfluidic devices is the ability to manipulate small sample volumes, thus reducing reagent waste and preserving precious sample. However, to achieve robust sample manipulation it is necessary to address device integration with the macroscale environment. To realize repeatable, sensitive particle separation with microfluidic devices, this protocol presents a complete automated and integrated microfluidic platform that enables precise processing of 0.15–1.5 ml samples using microfluidic devices. Important aspects of this system include modular device layout and robust fixtures resulting in reliable and flexible world to chip connections, and fully-automated fluid handling which accomplishes closed-loop sample collection,more » system cleaning and priming steps to ensure repeatable operation. Different microfluidic devices can be used interchangeably with this architecture. Here we incorporate an acoustofluidic device, detail its characterization, performance optimization, and demonstrate its use for size-separation of biological samples. By using real-time feedback during separation experiments, sample collection is optimized to conserve and concentrate sample. Although requiring the integration of multiple pieces of equipment, advantages of this architecture include the ability to process unknown samples with no additional system optimization, ease of device replacement, and precise, robust sample processing.« less

  15. The impact of Lean bundles on hospital performance: does size matter?

    PubMed

    Al-Hyari, Khalil; Abu Hammour, Sewar; Abu Zaid, Mohammad Khair Saleem; Haffar, Mohamed

    2016-10-10

    Purpose The purpose of this paper is to study the effect of the implementation of Lean bundles on hospital performance in private hospitals in Jordan and evaluate how much the size of organization can affect the relationship between Lean bundles implementation and hospital performance. Design/methodology/approach The research is considered as quantitative method (descriptive and hypothesis testing). Three statistical techniques were adopted to analyse the data. Structural equation modeling techniques and multi-group analysis were used to examine the research's hypothesis, and to perform the required statistical analysis of the data from the survey. Reliability analysis and confirmatory factor analysis were used to test the construct validity, reliability and measurement loadings that were performed. Findings Lean bundles have been identified as an effective approach that can dramatically improve the organizational performance of private hospitals in Jordan. Main Lean bundles - just in time, human resource management, and total quality management are applicable to large, small and medium hospitals without significant differences in advantages that depend on size. Originality/value According to the researchers' best knowledge, this is the first research that studies the impact of Lean bundles implementation in healthcare sector in Jordan. This research also makes a significant contribution for decision makers in healthcare to increase their awareness of Lean bundles.

  16. Everything is ok on YouTube! Quality assessment of YouTube videos on the topic of phacoemulsification in eyes with small pupil.

    PubMed

    Aykut, Aslan; Kukner, Amber Senel; Karasu, Bugra; Palancıglu, Yeliz; Atmaca, Fatih; Aydogan, Tumay

    2018-01-22

    Usage of YouTube as an educational tool is gaining attention in academic research. To date, there has been no study on the content and quality of eye surgery videos on YouTube. The aim of this study was to analyze YouTube videos on phacoemulsification in eyes with small pupil. We searched for the phrases "small pupil cataract surgery," "small pupil phacoemulsification," "small pupil cataract surgery complications," and "small pupil phacoemulsification complications" in January 2015. Each resulting video was evaluated by all authors, and Krippendorff's alpha was calculated to measure agreement. Videos were classified according to pupil size (small/very small) in the beginning of the surgery, and whether pupillary diameter was large enough to continue surgery safely after pupillary dilation by the surgeon in the video (safe/not safe). Methods of dilatation were also analyzed. Any stated ocular comorbidity or surgical complications were noted. A total of 96 videos were reviewed. No mechanical intervention for pupillary dilatation was performed in 46 videos. Fifty-eight operated eyes had no stated ocular comorbidity. Ninety-five operations ended successfully without major complication. There was fair agreement between the evaluators regarding pupil sizes (Kα = 0.670) but poor agreement regarding safety (Kα = 0.337). YouTube videos on small pupil phacoemulsification have low complication rates when compared to the literature, although no reliable mechanical dilatation methods are used in almost half of these videos. Until YouTube's place in e-learning becomes clearer, we suggest that viewers be cautious regarding small pupil phacoemulsification videos on YouTube.

  17. Trends in the evolution of life, brains and intelligence

    NASA Astrophysics Data System (ADS)

    Rospars, Jean-Pierre

    2013-07-01

    The f I term of Drake's equation - the fraction of life-bearing planets on which `intelligent' life evolved - has been the subject of much debate in the last few decades. Several leading evolutionary biologists have endorsed the thesis that the probability of intelligent life elsewhere in the universe is vanishingly small. A discussion of this thesis is proposed here that focuses on a key issue in the debate: the existence of evolutionary trends, often presented as trends towards higher complexity, and their possible significance. The present state of knowledge on trends is reviewed. Measurements of quantitative variables that describe important features of the evolution of living organisms - their hierarchical organization, size and biodiversity - and of brains - their overall size, the number and size of their components - in relation to their cognitive abilities, provide reliable evidence of the reality and generality of evolutionary trends. Properties of trends are inferred and frequent misinterpretations (including an excessive stress on mere `complexity') that prevent the objective assessment of trends are considered. Finally, several arguments against the repeatability of evolution to intelligence are discussed. It is concluded that no compelling argument exists for an exceedingly small probability f I. More research is needed before this wide-ranging negative conclusion is accepted.

  18. Bayesian evaluation of effect size after replicating an original study

    PubMed Central

    van Aert, Robbie C. M.; van Assen, Marcel A. L. M.

    2017-01-01

    The vast majority of published results in the literature is statistically significant, which raises concerns about their reliability. The Reproducibility Project Psychology (RPP) and Experimental Economics Replication Project (EE-RP) both replicated a large number of published studies in psychology and economics. The original study and replication were statistically significant in 36.1% in RPP and 68.8% in EE-RP suggesting many null effects among the replicated studies. However, evidence in favor of the null hypothesis cannot be examined with null hypothesis significance testing. We developed a Bayesian meta-analysis method called snapshot hybrid that is easy to use and understand and quantifies the amount of evidence in favor of a zero, small, medium and large effect. The method computes posterior model probabilities for a zero, small, medium, and large effect and adjusts for publication bias by taking into account that the original study is statistically significant. We first analytically approximate the methods performance, and demonstrate the necessity to control for the original study’s significance to enable the accumulation of evidence for a true zero effect. Then we applied the method to the data of RPP and EE-RP, showing that the underlying effect sizes of the included studies in EE-RP are generally larger than in RPP, but that the sample sizes of especially the included studies in RPP are often too small to draw definite conclusions about the true effect size. We also illustrate how snapshot hybrid can be used to determine the required sample size of the replication akin to power analysis in null hypothesis significance testing and present an easy to use web application (https://rvanaert.shinyapps.io/snapshot/) and R code for applying the method. PMID:28388646

  19. GAP/CL-20-Based Compound Explosive: A New Booster Formulation Used in a Small-Sized Initiation Network

    NASA Astrophysics Data System (ADS)

    Yanju, Wei; Jingyu, Wang; Chongwei, An; Hequn, Li; Xiaomu, Wen; Binshuo, Yu

    2017-01-01

    With ε-2,4,6,8,10,12-hexanitro-2,4,6,8,10,12-hexaazaisowurtzitane (CL-20) and glycidyl azide polymer (GAP) as the solid filler and binder, respectively, GAP/CL-20-based compound explosives were designed and prepared. Using micro injection charge technology, the compound explosives were packed into small grooves to explore their application in a small-sized initiation network. The detonation reliability, detonation velocity, mechanical sensitivity, shock sensitivity, and brisance of the explosive were measured and analyzed. The results show that when the solid content of CL-20 is 82 wt%, the explosive charged in the groove has a smooth surface from a macroscopic view. From a microscopic view, a coarse surface is bonded with many CL-20 particles by GAP binder. The GAP/CL-20-based explosive charge successfully generates detonation waves in a groove larger than 0.6 mm × 0.6 mm. When the charge density in the groove is 1.68 g.cm-3 (90% theoretical maximum density), the detonation velocity reaches 7,290 m.s-1. Moreover, this kind of explosive is characterized by low impact and shock sensitivity.

  20. Dosimetric evaluation of a MOSFET detector for clinical application in photon therapy.

    PubMed

    Kohno, Ryosuke; Hirano, Eriko; Nishio, Teiji; Miyagishi, Tomoko; Goka, Tomonori; Kawashima, Mitsuhiko; Ogino, Takashi

    2008-01-01

    Dosimetric characteristics of a metal oxide-silicon semiconductor field effect transistor (MOSFET) detector are studied with megavoltage photon beams for patient dose verification. The major advantages of this detector are its size, which makes it a point dosimeter, and its ease of use. In order to use the MOSFET detector for dose verification of intensity-modulated radiation therapy (IMRT) and in-vivo dosimetry for radiation therapy, we need to evaluate the dosimetric properties of the MOSFET detector. Therefore, we investigated the reproducibility, dose-rate effect, accumulated-dose effect, angular dependence, and accuracy in tissue-maximum ratio measurements. Then, as it takes about 20 min in actual IMRT for the patient, we evaluated fading effect of MOSFET response. When the MOSFETs were read-out 20 min after irradiation, we observed a fading effect of 0.9% with 0.9% standard error of the mean. Further, we applied the MOSFET to the measurement of small field total scatter factor. The MOSFET for dose measurements of small field sizes was better than the reference pinpoint chamber with vertical direction. In conclusion, we assessed the accuracy, reliability, and usefulness of the MOSFET detector in clinical applications such as pinpoint absolute dosimetry for small fields.

  1. ORDEM 3.0 and MASTER-2009 Modeled Small Debris Population Comparison

    NASA Technical Reports Server (NTRS)

    Krisko, P. H.; Flegel, S.

    2012-01-01

    The latest versions of the two premier orbital debris engineering models, NASA's ORDEM 3.0 and ESA's MASTER-2009, have been publicly released within the last year. Both models have gone through significant advancements since inception, and now represent the state-of-the-art in orbital debris knowledge of their respective agencies. The purpose of these models is to provide satellite designers/operators and debris researchers with reliable estimates of the artificial debris environment in near-Earth orbit. The small debris environment within the size range of 1 mm to 1 cm is of particular interest to both human and robotic spacecraft programs. These objects are much more numerous than larger trackable debris but are still large enough to cause significant, if not catastrophic, damage to spacecraft upon impact. They are also small enough to elude routine detection by existing observation systems (radar and telescope). Without reliable detection the modeling of these populations has always coupled theoretical origins with supporting observational data in different degrees. This paper describes the population generation and categorization of both ORDEM 3.0 and MASTER-2009; their sources (both known and presumed), current supporting data and theory, and methods of population verification. Fluxes on spacecraft for chosen orbits are presented and discussed. Future collaborative analysis is noted.

  2. ORDEM2010 and MASTER-2009 Modeled Small Debris Population Comparison

    NASA Technical Reports Server (NTRS)

    Krisko, Paula H.; Flegel, S.

    2010-01-01

    The latest versions of the two premier orbital debris engineering models, NASA s ORDEM2010 and ESA s MASTER-2009, have been publicly released. Both models have gone through significant advancements since inception, and now represent the state-of-the-art in orbital debris knowledge of their respective agencies. The purpose of these models is to provide satellite designers/operators and debris researchers with reliable estimates of the artificial debris environment in near-Earth orbit. The small debris environment within the size range of 1 mm to 1 cm is of particular interest to both human and robotic spacecraft programs. These objects are much more numerous than larger trackable debris but are still large enough to cause significant, if not catastrophic, damage to spacecraft upon impact. They are also small enough to elude routine detection by existing observation systems (radar and telescope). Without reliable detection the modeling of these populations has always coupled theoretical origins with supporting observational data in different degrees. This paper details the 1 mm to 1 cm orbital debris populations of both ORDEM2010 and MASTER-2009; their sources (both known and presumed), current supporting data and theory, and methods of population analysis. Fluxes on spacecraft for chosen orbits are also presented and discussed within the context of each model.

  3. What Are You Measuring? Dimensionality and Reliability Analysis of Ability and Speed in Medical School Didactic Examinations.

    PubMed

    Thompson, James J

    2016-01-01

    Summative didactic evaluation often involves multiple choice questions which are then aggregated into exam scores, course scores, and cumulative grade point averages. To be valid, each of these levels should have some relationship to the topic tested (dimensionality) and be sufficiently reproducible between persons (reliability) to justify student ranking. Evaluation of dimensionality is difficult and is complicated by the classic observation that didactic performance involves a generalized component (g) in addition to subtest specific factors. In this work, 183 students were analyzed over two academic years in 13 courses with 44 exams and 3352 questions for both accuracy and speed. Reliability at all levels was good (>0.95). Assessed by bifactor analysis, g effects dominated most levels resulting in essential unidimensionality. Effect sizes on predicted accuracy and speed due to nesting in exams and courses was small. There was little relationship between person ability and person speed. Thus, the hierarchical grading system appears warrented because of its g-dependence.

  4. Advanced Deployable Shell-Based Composite Booms for Small Satellite Structural Applications Including Solar Sails

    NASA Technical Reports Server (NTRS)

    Fernandez, Juan M.

    2017-01-01

    State of the art deployable structures are mainly being designed for medium to large size satellites. The lack of reliable deployable structural systems for low cost, small volume, rideshare-class spacecraft severely constrains the potential for using small satellite platforms for affordable deep space science and exploration precursor missions that could be realized with solar sails. There is thus a need for reliable, lightweight, high packaging efficiency deployable booms that can serve as the supporting structure for a wide range of small satellite systems including solar sails for propulsion. The National Air and Space Administration (NASA) is currently investing in the development of a new class of advanced deployable shell-based composite booms to support future deep space small satellite missions using solar sails. The concepts are being designed to: meet the unique requirements of small satellites, maximize ground testability, permit the use of low-cost manufacturing processes that will benefit scalability, be scalable for use as elements of hierarchical structures (e.g. trusses), allow long duration storage, have high deployment reliability, and have controlled deployment behavior and predictable deployed dynamics. This paper will present the various rollable boom concepts that are being developed for 5-20 m class size deployable structures that include solar sails with the so-called High Strain Composites (HSC) materials. The deployable composite booms to be presented are being developed to expand the portfolio of available rollable booms for small satellites and maximize their length for a given packaged volume. Given that solar sails are a great example of volume and mass optimization, the booms were designed to comply with nominal solar sail system requirements for 6U CubeSats, which are a good compromise between those of smaller form factors (1U, 2U and 3U CubeSats) and larger ones (12 U and 27 U future CubeSats, and ESPA-class microsatellites). Solar sail missions for such composite boom systems are already under consideration and development at NASA, as well as mission studies that will benefit from planned scaled-up versions of the composite boom technologies to be introduced. The paper presents ongoing research and development of thin-shell rollable composite booms designed under the particular stringent and challenging system requirements of relatively large solar sails housed on small satellites. These requirements will be derived and listed. Several new boom concepts are proposed and other existing ones are improved upon using thin-ply composite materials to yield unprecedented compact deployable structures. Some of these booms are shown in Fig. 1. For every boom to be introduced the scalable fabrication process developed to keep the overall boom system cost down will be shown. Finally, the initial results of purposely designed boom structural characterization test methods with gravity off-loading will be presented to compare their structural performance under expected and general load cases.

  5. ALCHEMY: a reliable method for automated SNP genotype calling for small batch sizes and highly homozygous populations

    PubMed Central

    Wright, Mark H.; Tung, Chih-Wei; Zhao, Keyan; Reynolds, Andy; McCouch, Susan R.; Bustamante, Carlos D.

    2010-01-01

    Motivation: The development of new high-throughput genotyping products requires a significant investment in testing and training samples to evaluate and optimize the product before it can be used reliably on new samples. One reason for this is current methods for automated calling of genotypes are based on clustering approaches which require a large number of samples to be analyzed simultaneously, or an extensive training dataset to seed clusters. In systems where inbred samples are of primary interest, current clustering approaches perform poorly due to the inability to clearly identify a heterozygote cluster. Results: As part of the development of two custom single nucleotide polymorphism genotyping products for Oryza sativa (domestic rice), we have developed a new genotype calling algorithm called ‘ALCHEMY’ based on statistical modeling of the raw intensity data rather than modelless clustering. A novel feature of the model is the ability to estimate and incorporate inbreeding information on a per sample basis allowing accurate genotyping of both inbred and heterozygous samples even when analyzed simultaneously. Since clustering is not used explicitly, ALCHEMY performs well on small sample sizes with accuracy exceeding 99% with as few as 18 samples. Availability: ALCHEMY is available for both commercial and academic use free of charge and distributed under the GNU General Public License at http://alchemy.sourceforge.net/ Contact: mhw6@cornell.edu Supplementary information: Supplementary data are available at Bioinformatics online. PMID:20926420

  6. A novel ultrasonic aerosol generator.

    PubMed

    Davies, A; Hudson, N; Pirie, L

    1995-07-01

    An ultrasonic aerosol generator constructed from a domestic humidifier is described which has been used to produce liquid aerosols for physiological investigations. The instrument was constructed from a Pifco domestic humidifier modified to include an energy guide to direct the oscillations of the transducer through the coupling water, which would normally be aerosolized, onto a small membrane based sample chamber containing the liquid to be aerosolized. The size distribution of the aerosol produced was found to be between 2 and 6 mm, optimum for diffuse intrapulmonary deposition. Up to 4 ml/min of aqueous liquid was used; however the sample chamber could be made small enough to contain economic amounts of expensive material to administer by inhalation. The instrument has proved to be reliable over a period of three years.

  7. DHS S&T First Responders Group and NATO Counter UAS Proposal Interest Response.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Salton, Jonathan R.

    The capability, speed, size, and widespread availability of small unmanned aerial systems (sUAS) makes them a serious security concern. The enabling technologies for sUAS are rapidly evolving and so too are the threats they pose to national security. Potential threat vehicles have a small cross-section, and are difficult to reliably detect using purely ground-based systems (e.g. radar or electro-optical) and challenging to target using conventional anti-aircraft defenses. Ground-based sensors are static and suffer from interference with the earth, vegetation and other man-made structures which obscure objects at low altitudes. Because of these challenges, sUAS pose a unique and rapidly evolvingmore » threat to national security.« less

  8. Identification of Deep Earthquakes

    DTIC Science & Technology

    2010-09-01

    discriminants that will reliably separate small, crustal earthquakes (magnitudes less than about 4 and depths less than about 40 to 50 km) from small...characteristics on discrimination plots designed to separate nuclear explosions from crustal earthquakes. Thus, reliably flagging these small, deep events is...Further, reliably identifying subcrustal earthquakes will allow us to eliminate deep events (previously misidentified as crustal earthquakes) from

  9. Hindlimb muscle architecture in non-human great apes and a comparison of methods for analysing inter-species variation

    PubMed Central

    Myatt, Julia P; Crompton, Robin H; Thorpe, Susannah K S

    2011-01-01

    By relating an animal's morphology to its functional role and the behaviours performed, we can further develop our understanding of the selective factors and constraints acting on the adaptations of great apes. Comparison of muscle architecture between different ape species, however, is difficult because only small sample sizes are ever available. Further, such samples are often comprised of different age–sex classes, so studies have to rely on scaling techniques to remove body mass differences. However, the reliability of such scaling techniques has been questioned. As datasets increase in size, more reliable statistical analysis may eventually become possible. Here we employ geometric and allometric scaling techniques, and ancovas (a form of general linear model, GLM) to highlight and explore the different methods available for comparing functional morphology in the non-human great apes. Our results underline the importance of regressing data against a suitable body size variable to ascertain the relationship (geometric or allometric) and of choosing appropriate exponents by which to scale data. ancova models, while likely to be more robust than scaling for species comparisons when sample sizes are high, suffer from reduced power when sample sizes are low. Therefore, until sample sizes are radically increased it is preferable to include scaling analyses along with ancovas in data exploration. Overall, the results obtained from the different methods show little significant variation, whether in muscle belly mass, fascicle length or physiological cross-sectional area between the different species. This may reflect relatively close evolutionary relationships of the non-human great apes; a universal influence on morphology of generalised orthograde locomotor behaviours or, quite likely, both. PMID:21507000

  10. Standardized mean differences cause funnel plot distortion in publication bias assessments.

    PubMed

    Zwetsloot, Peter-Paul; Van Der Naald, Mira; Sena, Emily S; Howells, David W; IntHout, Joanna; De Groot, Joris Ah; Chamuleau, Steven Aj; MacLeod, Malcolm R; Wever, Kimberley E

    2017-09-08

    Meta-analyses are increasingly used for synthesis of evidence from biomedical research, and often include an assessment of publication bias based on visual or analytical detection of asymmetry in funnel plots. We studied the influence of different normalisation approaches, sample size and intervention effects on funnel plot asymmetry, using empirical datasets and illustrative simulations. We found that funnel plots of the Standardized Mean Difference (SMD) plotted against the standard error (SE) are susceptible to distortion, leading to overestimation of the existence and extent of publication bias. Distortion was more severe when the primary studies had a small sample size and when an intervention effect was present. We show that using the Normalised Mean Difference measure as effect size (when possible), or plotting the SMD against a sample size-based precision estimate, are more reliable alternatives. We conclude that funnel plots using the SMD in combination with the SE are unsuitable for publication bias assessments and can lead to false-positive results.

  11. Standardized mean differences cause funnel plot distortion in publication bias assessments

    PubMed Central

    Van Der Naald, Mira; Sena, Emily S; Howells, David W; IntHout, Joanna; De Groot, Joris AH; Chamuleau, Steven AJ; MacLeod, Malcolm R

    2017-01-01

    Meta-analyses are increasingly used for synthesis of evidence from biomedical research, and often include an assessment of publication bias based on visual or analytical detection of asymmetry in funnel plots. We studied the influence of different normalisation approaches, sample size and intervention effects on funnel plot asymmetry, using empirical datasets and illustrative simulations. We found that funnel plots of the Standardized Mean Difference (SMD) plotted against the standard error (SE) are susceptible to distortion, leading to overestimation of the existence and extent of publication bias. Distortion was more severe when the primary studies had a small sample size and when an intervention effect was present. We show that using the Normalised Mean Difference measure as effect size (when possible), or plotting the SMD against a sample size-based precision estimate, are more reliable alternatives. We conclude that funnel plots using the SMD in combination with the SE are unsuitable for publication bias assessments and can lead to false-positive results. PMID:28884685

  12. Methodological aspects of an adaptive multidirectional pattern search to optimize speech perception using three hearing-aid algorithms

    NASA Astrophysics Data System (ADS)

    Franck, Bas A. M.; Dreschler, Wouter A.; Lyzenga, Johannes

    2004-12-01

    In this study we investigated the reliability and convergence characteristics of an adaptive multidirectional pattern search procedure, relative to a nonadaptive multidirectional pattern search procedure. The procedure was designed to optimize three speech-processing strategies. These comprise noise reduction, spectral enhancement, and spectral lift. The search is based on a paired-comparison paradigm, in which subjects evaluated the listening comfort of speech-in-noise fragments. The procedural and nonprocedural factors that influence the reliability and convergence of the procedure are studied using various test conditions. The test conditions combine different tests, initial settings, background noise types, and step size configurations. Seven normal hearing subjects participated in this study. The results indicate that the reliability of the optimization strategy may benefit from the use of an adaptive step size. Decreasing the step size increases accuracy, while increasing the step size can be beneficial to create clear perceptual differences in the comparisons. The reliability also depends on starting point, stop criterion, step size constraints, background noise, algorithms used, as well as the presence of drifting cues and suboptimal settings. There appears to be a trade-off between reliability and convergence, i.e., when the step size is enlarged the reliability improves, but the convergence deteriorates. .

  13. Tube focal spot size and power capability impact image quality in the evaluation of intracoronary stents

    NASA Astrophysics Data System (ADS)

    Cesmeli, Erdogan; Berry, Joel L.; Carr, J. J.

    2005-04-01

    Proliferation of coronary stent deployment for treatment of coronary heart disease (CHD) creates a need for imaging-based follow-up examinations to assess patency. Technological improvements in multi-detector computer tomography (MDCT) make it a potential non-invasive alternative to coronary catheterization for evaluation of stent patency; however, image quality with MDCT varies based on the size and composition of the stent. We studied the role of tube focal spot size and power in the optimization of image quality in a stationary phantom. A standard uniform physical phantom with a tubular insert was used where coronary stents (4 mm in diameter) were deployed in a tube filled with contrast to simulate a typical imaging condition observed in clinical practice. We utilized different commercially available stents and scanned them with different tube voltage and current settings (LightSpeed Pro16, GE Healthcare Technologies, Waukesha, WI, USA). The scanner used different focal spot size depending on the power load and thus allowed us to assess the combined effect of the focal spot size and the power. A radiologist evaluated the resulting images in terms of image quality and artifacts. For all stents, we found that the small focal spot size yielded better image quality and reduced artifacts. In general, higher power capability for the given focal spot size improved the signal-to-noise ratio in the images allowing improved assessment. Our preliminary study in a non-moving phantom suggests that a CT scanner that can deliver the same power on a small focal spot size is better suited to have an optimized scan protocol for reliable stent assessment.

  14. Field-scale electrolysis/ceramic membrane system for the treatment of sewage from decentralized small communities.

    PubMed

    Son, Dong-Jin; Kim, Woo-Yeol; Yun, Chan-Young; Kim, Dae-Gun; Chang, Duk; Sunwoo, Young; Hong, Ki-Ho

    2017-07-05

    The electrolysis process adopting copper electrodes and ceramic membrane with pore sizes of 0.1-0.2 μm were consisted to a system for the treatment of sewage from decentralized small communities. The system was operated under an HRT of 0.1 hour, voltage of 24 V, and TMP of 0.05 MPa. The system showed average removals of organics, nitrogen, phosphorus, and solids of up to 80%, 52%, 92%, and 100%, respectively. Removal of organics and nitrogen dramatically increased in proportion to increment of influent loading. Phosphorus and solids were remarkably eliminated by both electro-coagulation and membrane filtration. The residual particulate constituents could also be removed successfully through membrane process. A system composed of electrolysis process with ceramic membrane would be a compact, reliable, and flexible option for the treatment of sewage from decentralized small communities.

  15. Angiotensin-Converting Enzyme I/D Polymorphism and Preeclampsia Risk: Evidence of Small-Study Bias

    PubMed Central

    Serrano, Norma C; Díaz, Luis A; Páez, Maria C; Mesa, Clara M; Cifuentes, Rodrigo; Monterrosa, Alvaro; González, Adriana; Smeeth, Liam; Hingorani, Aroon D; Casas, Juan P

    2006-01-01

    Background Inappropriate activation of the renin–angiotensin system may play a part in the development of preeclampsia. An insertion/deletion polymorphism within the angiotensin-I converting enzyme gene (ACE-I/D) has shown to be reliably associated with differences in angiotensin-converting enzyme (ACE) activity. However, previous studies of the ACE-I/D variant and preeclampsia have been individually underpowered to detect plausible genotypic risks. Methods and Findings A prospective case-control study was conducted in 1,711 unrelated young pregnant women (665 preeclamptic and 1,046 healthy pregnant controls) recruited from five Colombian cities. Maternal blood was obtained to genotype for the ACE-I/D polymorphism. Crude and adjusted odds ratio (OR) and 95% confidence interval (CI) using logistic regression models were obtained to evaluate the strength of the association between ACE-I/D variant and preeclampsia risk. A meta-analysis was then undertaken of all published studies to February 2006 evaluating the ACE-I/D variant in preeclampsia. An additive model (per-D-allele) revealed a null association between the ACE-I/D variant and preeclampsia risk (crude OR = 0.95 [95% CI, 0.81–1.10]) in the new case-control study. Similar results were obtained after adjusting for confounders (adjusted per-allele OR = 0.90 [95% CI, 0.77–1.06]) and using other genetic models of inheritance. A meta-analysis (2,596 cases and 3,828 controls from 22 studies) showed a per-allele OR of 1.26 (95% CI, 1.07–1.49). An analysis stratified by study size showed an attenuated OR toward the null as study size increased. Conclusions It is highly likely that the observed small nominal increase in risk of preeclampsia associated with the ACE D-allele is due to small-study bias, similar to that observed in cardiovascular disease. Reliable assessment of the origins of preeclampsia using a genetic approach may require the establishment of a collaborating consortium to generate a dataset of adequate size. PMID:17194198

  16. Reliability and validity of two isometric squat tests.

    PubMed

    Blazevich, Anthony J; Gill, Nicholas; Newton, Robert U

    2002-05-01

    The purpose of the present study was first to examine the reliability of isometric squat (IS) and isometric forward hack squat (IFHS) tests to determine if repeated measures on the same subjects yielded reliable results. The second purpose was to examine the relation between isometric and dynamic measures of strength to assess validity. Fourteen male subjects performed maximal IS and IFHS tests on 2 occasions and 1 repetition maximum (1-RM) free-weight squat and forward hack squat (FHS) tests on 1 occasion. The 2 tests were found to be highly reliable (intraclass correlation coefficient [ICC](IS) = 0.97 and ICC(IFHS) = 1.00). There was a strong relation between average IS and 1-RM squat performance, and between IFHS and 1-RM FHS performance (r(squat) = 0.77, r(FHS) = 0.76; p < 0.01), but a weak relation between squat and FHS test performances (r < 0.55). There was also no difference between observed 1-RM values and those predicted by our regression equations. Errors in predicting 1-RM performance were in the order of 8.5% (standard error of the estimate [SEE] = 13.8 kg) and 7.3% (SEE = 19.4 kg) for IS and IFHS respectively. Correlations between isometric and 1-RM tests were not of sufficient size to indicate high validity of the isometric tests. Together the results suggest that IS and IFHS tests could detect small differences in multijoint isometric strength between subjects, or performance changes over time, and that the scores in the isometric tests are well related to 1-RM performance. However, there was a small error when predicting 1-RM performance from isometric performance, and these tests have not been shown to discriminate between small changes in dynamic strength. The weak relation between squat and FHS test performance can be attributed to differences in the movement patterns of the tests

  17. 3D MEMS in Standard Processes: Fabrication, Quality Assurance, and Novel Measurement Microstructures

    NASA Technical Reports Server (NTRS)

    Lin, Gisela; Lawton, Russell A.

    2000-01-01

    Three-dimensional MEMS microsystems that are commercially fabricated require minimal post-processing and are easily integrated with CMOS signal processing electronics. Measurements to evaluate the fabrication process (such as cross-sectional imaging and device performance characterization) provide much needed feedback in terms of reliability and quality assurance. MEMS technology is bringing a new class of microscale measurements to fruition. The relatively small size of MEMS microsystems offers the potential for higher fidelity recordings compared to macrosize counterparts, as illustrated in the measurement of muscle cell forces.

  18. Government and industry interactions in the development of clock technology

    NASA Technical Reports Server (NTRS)

    Hellwig, H.

    1981-01-01

    It appears likely that everyone in the time and frequency community can agree on goals to be realized through the expenditure of resources. These goals are the same as found in most fields of technology: lower cost, better performance, increased reliability, small size and lower power. Related aspects are examined in the process of clock and frequency standard development. Government and industry are reviewed in a highly interactive role. These interactions include judgements on clock performance, what kind of clock, expenditure of resources, transfer of ideas or hardware concepts from government to industry, and control of production. Successful clock development and production requires a government/industry relationship which is characterized by long-term continuity, multidisciplinary team work, focused funding and a separation of reliability and production oriented tasks from performance improvement/research type efforts.

  19. The proximally based long peroneal muscle turnover flap: A novel salvage flap for small to medium-sized defects of the knee.

    PubMed

    Wagner, Till; Hupkens, Pieter; Slater, Nicholas J; Ulrich, Dietmar J O

    2016-04-01

    Coverage of soft-tissue defects of the knee due to multiple operations, trauma, and infection remains a surgical challenge. Often, these defects are repaired using free tissue transfer. The aim of this study was to find an easy and reliable local method of repair for small to medium-sized defects. The authors describe a new surgical option for tissue coverage using a proximally based long peroneal muscle turnover flap (LPTF) with split-thickness skin graft. Proximally based LPTFs were harvested and transposed into same-size created defects in five cadavers. After optimizing this technique, it was clinically used in two patients with defects secondary to total knee replacement revisions. Average cadaver flap size was 4.7 × 15.8 cm allowing reach of all knee joint areas and was based consistently on a sufficient (2-mm-diameter average) proximal arterial branch of the anterior tibial artery. Donor sites were closed without tension. Subsequent application of the flap on two patients resulted in good functional outcome. The proximally based LPTF is a new option available in the reconstruction of knee defects and should be added to the reconstructive surgeon's armamentarium of pedicled flaps, providing short operating time and promising clinical outcome. Copyright © 2015 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  20. Development of an on-line exposure system to determine freshly produced diesel engine emission-induced cellular effects.

    PubMed

    Oostingh, Gertie J; Papaioannou, Eleni; Chasapidis, Leonidas; Akritidis, Theofylaktos; Konstandopoulos, Athanasios G; Duschl, Albert

    2013-09-01

    Diesel engine emission particle filters are often placed at exhaust outlets to remove particles from the exhaust. The use of filters results in the exposure to a reduced number of nanometer-sized particles, which might be more harmful than the exposure to a larger number of micrometer-sized particles. An in vitro exposure system was established to expose human alveolar epithelial cells to freshly generated exhaust. Computer simulations were used to determine the optimal flow characteristics and ensure equal exposure conditions for each well of a 6-well plate. A selective particle size sampler was used to continuously deliver diesel soot particles with different particle size distributions to cells in culture. To determine, whether the system could be used for cellular assays, alterations in cytokine production and cell viability of human alveolar A549 cells were determined after 3h on-line exposure followed by a 21-h conventional incubation period. Data indicated that complete diesel engine emission slightly affected pre-stimulated cells, but naive cells were not affected. The fractions containing large or small particles never affected the cells. The experimental set-up allowed a reliable exposure of the cells to the complete exhaust fraction or to the fractions containing either large or small diesel engine emission particles. Copyright © 2013 Elsevier Ltd. All rights reserved.

  1. Sizing protein-templated gold nanoclusters by time resolved fluorescence anisotropy decay measurements.

    PubMed

    Soleilhac, Antonin; Bertorelle, Franck; Antoine, Rodolphe

    2018-03-15

    Protein-templated gold nanoclusters (AuNCs) are very attractive due to their unique fluorescence properties. A major problem however may arise due to protein structure changes upon the nucleation of an AuNC within the protein for any future use as in vivo probes, for instance. In this work, we propose a simple and reliable fluorescence based technique measuring the hydrodynamic size of protein-templated gold nanoclusters. This technique uses the relation between the time resolved fluorescence anisotropy decay and the hydrodynamic volume, through the rotational correlation time. We determine the molecular size of protein-directed AuNCs, with protein templates of increasing sizes, e.g. insulin, lysozyme, and bovine serum albumin (BSA). The comparison of sizes obtained by other techniques (e.g. dynamic light scattering and small-angle X-ray scattering) between bare and gold clusters containing proteins allows us to address the volume changes induced either by conformational changes (for BSA) or the formation of protein dimers (for insulin and lysozyme) during cluster formation and incorporation. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. On the Structure of Cortical Microcircuits Inferred from Small Sample Sizes.

    PubMed

    Vegué, Marina; Perin, Rodrigo; Roxin, Alex

    2017-08-30

    The structure in cortical microcircuits deviates from what would be expected in a purely random network, which has been seen as evidence of clustering. To address this issue, we sought to reproduce the nonrandom features of cortical circuits by considering several distinct classes of network topology, including clustered networks, networks with distance-dependent connectivity, and those with broad degree distributions. To our surprise, we found that all of these qualitatively distinct topologies could account equally well for all reported nonrandom features despite being easily distinguishable from one another at the network level. This apparent paradox was a consequence of estimating network properties given only small sample sizes. In other words, networks that differ markedly in their global structure can look quite similar locally. This makes inferring network structure from small sample sizes, a necessity given the technical difficulty inherent in simultaneous intracellular recordings, problematic. We found that a network statistic called the sample degree correlation (SDC) overcomes this difficulty. The SDC depends only on parameters that can be estimated reliably given small sample sizes and is an accurate fingerprint of every topological family. We applied the SDC criterion to data from rat visual and somatosensory cortex and discovered that the connectivity was not consistent with any of these main topological classes. However, we were able to fit the experimental data with a more general network class, of which all previous topologies were special cases. The resulting network topology could be interpreted as a combination of physical spatial dependence and nonspatial, hierarchical clustering. SIGNIFICANCE STATEMENT The connectivity of cortical microcircuits exhibits features that are inconsistent with a simple random network. Here, we show that several classes of network models can account for this nonrandom structure despite qualitative differences in their global properties. This apparent paradox is a consequence of the small numbers of simultaneously recorded neurons in experiment: when inferred via small sample sizes, many networks may be indistinguishable despite being globally distinct. We develop a connectivity measure that successfully classifies networks even when estimated locally with a few neurons at a time. We show that data from rat cortex is consistent with a network in which the likelihood of a connection between neurons depends on spatial distance and on nonspatial, asymmetric clustering. Copyright © 2017 the authors 0270-6474/17/378498-13$15.00/0.

  3. Reliability of 3-Dimensional Measures of Single-Leg Cross Drop Landing Across 3 Different Institutions: Implications for Multicenter Biomechanical and Epidemiological Research on ACL Injury Prevention.

    PubMed

    DiCesare, Christopher A; Bates, Nathaniel A; Barber Foss, Kim D; Thomas, Staci M; Wordeman, Samuel C; Sugimoto, Dai; Roewer, Benjamin D; Medina McKeon, Jennifer M; Di Stasi, Stephanie; Noehren, Brian W; Ford, Kevin R; Kiefer, Adam W; Hewett, Timothy E; Myer, Gregory D

    2015-12-01

    Anterior cruciate ligament (ACL) injuries are physically and financially devastating but affect a relatively small percentage of the population. Prospective identification of risk factors for ACL injury necessitates a large sample size; therefore, study of this injury would benefit from a multicenter approach. To determine the reliability of kinematic and kinetic measures of a single-leg cross drop task across 3 institutions. Controlled laboratory study. Twenty-five female high school volleyball players participated in this study. Three-dimensional motion data of each participant performing the single-leg cross drop were collected at 3 institutions over a period of 4 weeks. Coefficients of multiple correlation were calculated to assess the reliability of kinematic and kinetic measures during the landing phase of the movement. Between-centers reliability for kinematic waveforms in the frontal and sagittal planes was good, but moderate in the transverse plane. Between-centers reliability for kinetic waveforms was good in the sagittal, frontal, and transverse planes. Based on these findings, the single-leg cross drop task has moderate to good reliability of kinematic and kinetic measures across institutions after implementation of a standardized testing protocol. Multicenter collaborations can increase study numbers and generalize results, which is beneficial for studies of relatively rare phenomena, such as ACL injury. An important step is to determine the reliability of risk assessments across institutions before a multicenter collaboration can be initiated.

  4. Reliability of 3-Dimensional Measures of Single-Leg Cross Drop Landing Across 3 Different Institutions

    PubMed Central

    DiCesare, Christopher A.; Bates, Nathaniel A.; Barber Foss, Kim D.; Thomas, Staci M.; Wordeman, Samuel C.; Sugimoto, Dai; Roewer, Benjamin D.; Medina McKeon, Jennifer M.; Di Stasi, Stephanie; Noehren, Brian W.; Ford, Kevin R.; Kiefer, Adam W.; Hewett, Timothy E.; Myer, Gregory D.

    2015-01-01

    Background: Anterior cruciate ligament (ACL) injuries are physically and financially devastating but affect a relatively small percentage of the population. Prospective identification of risk factors for ACL injury necessitates a large sample size; therefore, study of this injury would benefit from a multicenter approach. Purpose: To determine the reliability of kinematic and kinetic measures of a single-leg cross drop task across 3 institutions. Study Design: Controlled laboratory study. Methods: Twenty-five female high school volleyball players participated in this study. Three-dimensional motion data of each participant performing the single-leg cross drop were collected at 3 institutions over a period of 4 weeks. Coefficients of multiple correlation were calculated to assess the reliability of kinematic and kinetic measures during the landing phase of the movement. Results: Between-centers reliability for kinematic waveforms in the frontal and sagittal planes was good, but moderate in the transverse plane. Between-centers reliability for kinetic waveforms was good in the sagittal, frontal, and transverse planes. Conclusion: Based on these findings, the single-leg cross drop task has moderate to good reliability of kinematic and kinetic measures across institutions after implementation of a standardized testing protocol. Clinical Relevance: Multicenter collaborations can increase study numbers and generalize results, which is beneficial for studies of relatively rare phenomena, such as ACL injury. An important step is to determine the reliability of risk assessments across institutions before a multicenter collaboration can be initiated. PMID:26779550

  5. The reliability and validity of ultrasound to quantify muscles in older adults: a systematic review

    PubMed Central

    Scafoglieri, Aldo; Jager‐Wittenaar, Harriët; Hobbelen, Johannes S.M.; van der Schans, Cees P.

    2017-01-01

    Abstract This review evaluates the reliability and validity of ultrasound to quantify muscles in older adults. The databases PubMed, Cochrane, and Cumulative Index to Nursing and Allied Health Literature were systematically searched for studies. In 17 studies, the reliability (n = 13) and validity (n = 8) of ultrasound to quantify muscles in community‐dwelling older adults (≥60 years) or a clinical population were evaluated. Four out of 13 reliability studies investigated both intra‐rater and inter‐rater reliability. Intraclass correlation coefficient (ICC) scores for reliability ranged from −0.26 to 1.00. The highest ICC scores were found for the vastus lateralis, rectus femoris, upper arm anterior, and the trunk (ICC = 0.72 to 1.000). All included validity studies found ICC scores ranging from 0.92 to 0.999. Two studies describing the validity of ultrasound to predict lean body mass showed good validity as compared with dual‐energy X‐ray absorptiometry (r 2 = 0.92 to 0.96). This systematic review shows that ultrasound is a reliable and valid tool for the assessment of muscle size in older adults. More high‐quality research is required to confirm these findings in both clinical and healthy populations. Furthermore, ultrasound assessment of small muscles needs further evaluation. Ultrasound to predict lean body mass is feasible; however, future research is required to validate prediction equations in older adults with varying function and health. PMID:28703496

  6. GEO Collisional Risk Assessment Based on Analysis of NASA-WISE Data and Modeling

    NASA Astrophysics Data System (ADS)

    Howard, S.; Murray-Krezan, J.; Dao, P.; Surka, D.

    From December 2009 thru 2011 the NASA Wide-Field Infrared Survey Explorer (WISE) gathered radiometrically exquisite measurements of debris in near Earth orbits, substantially augmenting the current catalog of known debris. The WISE GEO-belt debris population adds approximately 2,000 previously uncataloged objects. This paper describes characterization of the WISE GEO-belt orbital debris population in terms of location, epoch, and size. The WISE GEO-belt debris population characteristics are compared with the publically available U.S. catalog and previous descriptions of the GEO-belt debris population. We found that our results differ from previously published debris distributions, suggesting the need for updates to collision probability models and a better measurement-based understanding of the debris population. Previous studies of collisional rate in GEO invoke the presence of a large number of debris in the regime of sizes too small to track, i.e. not in the catalog, but large enough to cause significant damage and fragmentation in a collision. A common approach is to estimate that population of small debris by assuming that it is dominated by fragments and therefore should follow trends observed in fragmentation events or laboratory fragmentation tests. In other words, the population of debris can be extrapolated from trackable sizes to small sizes using an empirically determined trend of population as a function of size. We use new information suggested by the analysis of WISE IR measurements to propose an updated relationship. Our trend is an improvement because we expect that an IR emissive signature is a more reliable indicator of physical size. Based on the revised relationship, we re-estimate the total collisional rate in the GEO belt with the inclusion of projected uncatalogued debris and applying a conjunction assessment technique. Through modeling, we evaluate the hot spots near the geopotential wells and the effects of fragmentation in the GEO graveyard to the collision with GEO objects.

  7. Monitoring Dolphins in an Urban Marine System: Total and Effective Population Size Estimates of Indo-Pacific Bottlenose Dolphins in Moreton Bay, Australia

    PubMed Central

    Ansmann, Ina C.; Lanyon, Janet M.; Seddon, Jennifer M.; Parra, Guido J.

    2013-01-01

    Moreton Bay, Queensland, Australia is an area of high biodiversity and conservation value and home to two sympatric sub-populations of Indo-Pacific bottlenose dolphins (Tursiops aduncus). These dolphins live in close proximity to major urban developments. Successful management requires information regarding their abundance. Here, we estimate total and effective population sizes of bottlenose dolphins in Moreton Bay using photo-identification and genetic data collected during boat-based surveys in 2008–2010. Abundance (N) was estimated using open population mark-recapture models based on sighting histories of distinctive individuals. Effective population size (Ne) was estimated using the linkage disequilibrium method based on nuclear genetic data at 20 microsatellite markers in skin samples, and corrected for bias caused by overlapping generations (Nec). A total of 174 sightings of dolphin groups were recorded and 365 different individuals identified. Over the whole of Moreton Bay, a population size N of 554±22.2 (SE) (95% CI: 510–598) was estimated. The southern bay sub-population was small at an estimated N = 193±6.4 (SE) (95% CI: 181–207), while the North sub-population was more numerous, with 446±56 (SE) (95% CI: 336–556) individuals. The small estimated effective population size of the southern sub-population (Nec = 56, 95% CI: 33–128) raises conservation concerns. A power analysis suggested that to reliably detect small (5%) declines in size of this population would require substantial survey effort (>4 years of annual mark-recapture surveys) at the precision levels achieved here. To ensure that ecological as well as genetic diversity within this population of bottlenose dolphins is preserved, we consider that North and South sub-populations should be treated as separate management units. Systematic surveys over smaller areas holding locally-adapted sub-populations are suggested as an alternative method for increasing ability to detect abundance trends. PMID:23755197

  8. Management of colorectal emergencies: percutaneous abscess drainage.

    PubMed

    Brusciano, L; Maffettone, V; Napolitano, V; Izzo, G; Rossetti, G; Izzo, D; Russo, F; Russo, G; del Genio, G; del Genio, A

    2004-01-01

    Pelvic abscesses represent the most frequent complications of colorectal surgery. Percutaneous CT or US guided drainage can be an alternative to surgical drainage that is associated to a significant mortality rate. In the current study results of PAD, performed in 39 patients with pelvic or abdominopelvic abscesses were reviewed in order to evaluate reliability of such procedure. Major part of the collections 33/39 (85%) developed after resective colorectal surgery, and 20/39 (51%) were associated to anastomotic fistula; 22/39 (56%) were poorly defined; 16/39 (41%) were multiloculated; 16/39 (41%) had a stool contamination, 23/39 (58%) were greater than 10 cm; 14/39 (35%) were multiple. Thirty-five patients (89.7%) healed, despite high number of complex abscesses and complete resolution of sepsis was achieved in 5.1 +/- 2.9 days. CT proved to be the most reliable tool in assessing distinctive features of collections as well as in identifying the best route for drainage. Adequate size of the catheter was essential to get an effective drainage. In particular, large sized catheter (> 20 Fr) had to be used to drain collections associated to anastomotic fistulas with stool contamination. In four elderly neoplastic patients with chronic illnesses (10%), only a single small sized catheter could be positioned, because of patients poor compliance and PAD was inaffective. Nevertheless even those patients got a partial resolution of the sepsis and their general conditions markedly improved, so that they were able to underwent successful surgical drainage. In conclusion PAD is a safe and reliable tool that can be employed as an alternative to surgical drainage at least as first measure, even if complex pelvic abscesses are found.

  9. Using pilot data to size a two-arm randomized trial to find a nearly optimal personalized treatment strategy.

    PubMed

    Laber, Eric B; Zhao, Ying-Qi; Regh, Todd; Davidian, Marie; Tsiatis, Anastasios; Stanford, Joseph B; Zeng, Donglin; Song, Rui; Kosorok, Michael R

    2016-04-15

    A personalized treatment strategy formalizes evidence-based treatment selection by mapping patient information to a recommended treatment. Personalized treatment strategies can produce better patient outcomes while reducing cost and treatment burden. Thus, among clinical and intervention scientists, there is a growing interest in conducting randomized clinical trials when one of the primary aims is estimation of a personalized treatment strategy. However, at present, there are no appropriate sample size formulae to assist in the design of such a trial. Furthermore, because the sampling distribution of the estimated outcome under an estimated optimal treatment strategy can be highly sensitive to small perturbations in the underlying generative model, sample size calculations based on standard (uncorrected) asymptotic approximations or computer simulations may not be reliable. We offer a simple and robust method for powering a single stage, two-armed randomized clinical trial when the primary aim is estimating the optimal single stage personalized treatment strategy. The proposed method is based on inverting a plugin projection confidence interval and is thereby regular and robust to small perturbations of the underlying generative model. The proposed method requires elicitation of two clinically meaningful parameters from clinical scientists and uses data from a small pilot study to estimate nuisance parameters, which are not easily elicited. The method performs well in simulated experiments and is illustrated using data from a pilot study of time to conception and fertility awareness. Copyright © 2015 John Wiley & Sons, Ltd.

  10. A new design of facial artery perforator flaps for the reconstruction of small- to medium-sized intraoral defects.

    PubMed

    Du, Yi-fei; Zhou, Wei-na; Li, Jie; Jiang, Hong-bing; Yuan, Hua; Wan, Lin-zhong

    2014-11-01

    The aim of this study was to investigate the reliability and outcomes of a new design of facial artery perforator flaps, extending from the angle of the mouth to the border of the mandible, for the reconstruction of small- to medium-sized intraoral defects. The technique had been used in 23 patients between February 2009 and August 2012. The locations of intraoral defects included the tongue, the floor of the mouth, the inferior gingival mucosa, and the sublingual gland. All flaps were monitored for complications including skin loss and ischemia. The functions of appearance, swallowing, and speech were assessed 6 months after operation with the University of Washington Quality of Life Questionnaire. All flaps presented with satisfactory results except for one, which demonstrated superficial tip necrosis that settled after conservative treatment. The follow-up period ranged from 6 to 12 months, and 1 patient died as a result of pulmonary metastasis, and 3 patients underwent second surgery because of local tumor recurrence (2patients) and cervical recurrence (1 patient). Nineteen patients were assessed with the University of Washington Quality of Life Questionnaire, and the mean (SD) scores of appearance, swallowing, and speech were 57.89 (14.45), 83.68 (19.98), and 81.58 (23.16), respectively. This design of facial artery perforator flaps could provide an efficient and cost-effective method for reconstruction of small- to medium-sized intraoral defects with a low surgical morbidity and satisfactory levels of quality of life.

  11. Reliably detectable flaw size for NDE methods that use calibration

    NASA Astrophysics Data System (ADS)

    Koshti, Ajay M.

    2017-04-01

    Probability of detection (POD) analysis is used in assessing reliably detectable flaw size in nondestructive evaluation (NDE). MIL-HDBK-1823 and associated mh18232 POD software gives most common methods of POD analysis. In this paper, POD analysis is applied to an NDE method, such as eddy current testing, where calibration is used. NDE calibration standards have known size artificial flaws such as electro-discharge machined (EDM) notches and flat bottom hole (FBH) reflectors which are used to set instrument sensitivity for detection of real flaws. Real flaws such as cracks and crack-like flaws are desired to be detected using these NDE methods. A reliably detectable crack size is required for safe life analysis of fracture critical parts. Therefore, it is important to correlate signal responses from real flaws with signal responses form artificial flaws used in calibration process to determine reliably detectable flaw size.

  12. Reliably Detectable Flaw Size for NDE Methods that Use Calibration

    NASA Technical Reports Server (NTRS)

    Koshti, Ajay M.

    2017-01-01

    Probability of detection (POD) analysis is used in assessing reliably detectable flaw size in nondestructive evaluation (NDE). MIL-HDBK-1823 and associated mh1823 POD software gives most common methods of POD analysis. In this paper, POD analysis is applied to an NDE method, such as eddy current testing, where calibration is used. NDE calibration standards have known size artificial flaws such as electro-discharge machined (EDM) notches and flat bottom hole (FBH) reflectors which are used to set instrument sensitivity for detection of real flaws. Real flaws such as cracks and crack-like flaws are desired to be detected using these NDE methods. A reliably detectable crack size is required for safe life analysis of fracture critical parts. Therefore, it is important to correlate signal responses from real flaws with signal responses form artificial flaws used in calibration process to determine reliably detectable flaw size.

  13. A small-diameter NMR logging tool for groundwater investigations

    USGS Publications Warehouse

    Walsh, David; Turner, Peter; Grunewald, Elliot; Zhang, Hong; Butler, James J.; Reboulet, Ed; Knobbe, Steve; Christy, Tom; Lane, John W.; Johnson, Carole D.; Munday, Tim; Fitzpatrick, Andrew

    2013-01-01

    A small-diameter nuclear magnetic resonance (NMR) logging tool has been developed and field tested at various sites in the United States and Australia. A novel design approach has produced relatively inexpensive, small-diameter probes that can be run in open or PVC-cased boreholes as small as 2 inches in diameter. The complete system, including surface electronics and various downhole probes, has been successfully tested in small-diameter monitoring wells in a range of hydrogeological settings. A variant of the probe that can be deployed by a direct-push machine has also been developed and tested in the field. The new NMR logging tool provides reliable, direct, and high-resolution information that is of importance for groundwater studies. Specifically, the technology provides direct measurement of total water content (total porosity in the saturated zone or moisture content in the unsaturated zone), and estimates of relative pore-size distribution (bound vs. mobile water content) and hydraulic conductivity. The NMR measurements show good agreement with ancillary data from lithologic logs, geophysical logs, and hydrogeologic measurements, and provide valuable information for groundwater investigations.

  14. A meta-data based method for DNA microarray imputation.

    PubMed

    Jörnsten, Rebecka; Ouyang, Ming; Wang, Hui-Yu

    2007-03-29

    DNA microarray experiments are conducted in logical sets, such as time course profiling after a treatment is applied to the samples, or comparisons of the samples under two or more conditions. Due to cost and design constraints of spotted cDNA microarray experiments, each logical set commonly includes only a small number of replicates per condition. Despite the vast improvement of the microarray technology in recent years, missing values are prevalent. Intuitively, imputation of missing values is best done using many replicates within the same logical set. In practice, there are few replicates and thus reliable imputation within logical sets is difficult. However, it is in the case of few replicates that the presence of missing values, and how they are imputed, can have the most profound impact on the outcome of downstream analyses (e.g. significance analysis and clustering). This study explores the feasibility of imputation across logical sets, using the vast amount of publicly available microarray data to improve imputation reliability in the small sample size setting. We download all cDNA microarray data of Saccharomyces cerevisiae, Arabidopsis thaliana, and Caenorhabditis elegans from the Stanford Microarray Database. Through cross-validation and simulation, we find that, for all three species, our proposed imputation using data from public databases is far superior to imputation within a logical set, sometimes to an astonishing degree. Furthermore, the imputation root mean square error for significant genes is generally a lot less than that of non-significant ones. Since downstream analysis of significant genes, such as clustering and network analysis, can be very sensitive to small perturbations of estimated gene effects, it is highly recommended that researchers apply reliable data imputation prior to further analysis. Our method can also be applied to cDNA microarray experiments from other species, provided good reference data are available.

  15. Population size influences amphibian detection probability: implications for biodiversity monitoring programs.

    PubMed

    Tanadini, Lorenzo G; Schmidt, Benedikt R

    2011-01-01

    Monitoring is an integral part of species conservation. Monitoring programs must take imperfect detection of species into account in order to be reliable. Theory suggests that detection probability may be determined by population size but this relationship has not yet been assessed empirically. Population size is particularly important because it may induce heterogeneity in detection probability and thereby cause bias in estimates of biodiversity. We used a site occupancy model to analyse data from a volunteer-based amphibian monitoring program to assess how well different variables explain variation in detection probability. An index to population size best explained detection probabilities for four out of six species (to avoid circular reasoning, we used the count of individuals at a previous site visit as an index to current population size). The relationship between the population index and detection probability was positive. Commonly used weather variables best explained detection probabilities for two out of six species. Estimates of site occupancy probabilities differed depending on whether the population index was or was not used to model detection probability. The relationship between the population index and detectability has implications for the design of monitoring and species conservation. Most importantly, because many small populations are likely to be overlooked, monitoring programs should be designed in such a way that small populations are not overlooked. The results also imply that methods cannot be standardized in such a way that detection probabilities are constant. As we have shown here, one can easily account for variation in population size in the analysis of data from long-term monitoring programs by using counts of individuals from surveys at the same site in previous years. Accounting for variation in population size is important because it can affect the results of long-term monitoring programs and ultimately the conservation of imperiled species.

  16. A thermally driven differential mutation approach for the structural optimization of large atomic systems

    NASA Astrophysics Data System (ADS)

    Biswas, Katja

    2017-09-01

    A computational method is presented which is capable to obtain low lying energy structures of topological amorphous systems. The method merges a differential mutation genetic algorithm with simulated annealing. This is done by incorporating a thermal selection criterion, which makes it possible to reliably obtain low lying minima with just a small population size and is suitable for multimodal structural optimization. The method is tested on the structural optimization of amorphous graphene from unbiased atomic starting configurations. With just a population size of six systems, energetically very low structures are obtained. While each of the structures represents a distinctly different arrangement of the atoms, their properties, such as energy, distribution of rings, radial distribution function, coordination number, and distribution of bond angles, are very similar.

  17. Estimating cirrus cloud properties from MIPAS data

    NASA Astrophysics Data System (ADS)

    Mendrok, J.; Schreier, F.; Höpfner, M.

    2007-04-01

    High resolution mid-infrared limb emission spectra observed by the spaceborne Michelson Interferometer for Passive Atmospheric Sounding (MIPAS) showing evidence of cloud interference are analyzed. Using the new line-by-line multiple scattering [Approximate] Spherical Atmospheric Radiative Transfer code (SARTre), a sensitivity study with respect to cirrus cloud parameters, e.g., optical thickness and particle size distribution, is performed. Cirrus properties are estimated by fitting spectra in three distinct microwindows between 8 and 12 μm. For a cirrus with extremely low ice water path (IWP = 0.1 g/m2) and small effective particle size (D e = 10 μm) simulated spectra are in close agreement with observations in broadband signal and fine structures. We show that a multi-microwindow technique enhances reliability of MIPAS cirrus retrievals compared to single microwindow methods.

  18. ABLE project: Development of an advanced lead-acid storage system for autonomous PV installations

    NASA Astrophysics Data System (ADS)

    Lemaire-Potteau, Elisabeth; Vallvé, Xavier; Pavlov, Detchko; Papazov, G.; Borg, Nico Van der; Sarrau, Jean-François

    In the advanced battery for low-cost renewable energy (ABLE) project, the partners have developed an advanced storage system for small and medium-size PV systems. It is composed of an innovative valve-regulated lead-acid (VRLA) battery, optimised for reliability and manufacturing cost, and an integrated regulator, for optimal battery management and anti-fraudulent use. The ABLE battery performances are comparable to flooded tubular batteries, which are the reference in medium-size PV systems. The ABLE regulator has several innovative features regarding energy management and modular series/parallel association. The storage system has been validated by indoor, outdoor and field tests, and it is expected that this concept could be a major improvement for large-scale implementation of PV within the framework of national rural electrification schemes.

  19. Application of Au-Sn eutectic bonding in hermetic radio-frequency microelectromechanical system wafer level packaging

    NASA Astrophysics Data System (ADS)

    Wang, Qian; Choa, Sung-Hoon; Kim, Woonbae; Hwang, Junsik; Ham, Sukjin; Moon, Changyoul

    2006-03-01

    Development of packaging is one of the critical issues toward realizing commercialization of radio-frequency-microelectromechanical system (RF-MEMS) devices. The RF-MEMS package should be designed to have small size, hermetic protection, good RF performance, and high reliability. In addition, packaging should be conducted at sufficiently low temperature. In this paper, a low-temperature hermetic wafer level packaging scheme for the RF-MEMS devices is presented. For hermetic sealing, Au-Sn eutectic bonding technology at temperatures below 300°C is used. Au-Sn multilayer metallization with a square loop of 70 µm in width is performed. The electrical feed-through is achieved by the vertical through-hole via filling with electroplated Cu. The size of the MEMS package is 1 mm × 1 mm × 700 µm. The shear strength and hermeticity of the package satisfies the requirements of MIL-STD-883F. Any organic gases or contamination are not observed inside the package. The total insertion loss for the packaging is 0.075 dB at 2 GHz. Furthermore, the robustness of the package is demonstrated by observing no performance degradation and physical damage of the package after several reliability tests.

  20. The Maximum standardized uptake value is more reliable than size measurement in early follow-up to evaluate potential pulmonary malignancies following radiofrequency ablation.

    PubMed

    Alafate, Aierken; Shinya, Takayoshi; Okumura, Yoshihiro; Sato, Shuhei; Hiraki, Takao; Ishii, Hiroaki; Gobara, Hideo; Kato, Katsuya; Fujiwara, Toshiyoshi; Miyoshi, Shinichiro; Kaji, Mitsumasa; Kanazawa, Susumu

    2013-01-01

    We retrospectively evaluated the accumulation of fluorodeoxy glucose (FDG) in pulmonary malignancies without local recurrence during 2-year follow-up on positron emission tomography (PET)/computed tomography (CT) after radiofrequency ablation (RFA). Thirty tumors in 25 patients were studied (10 non-small cell lung cancers;20 pulmonary metastatic tumors). PET/CT was performed before RFA, 3 months after RFA, and 6 months after RFA. We assessed the FDG accumulation with the maximum standardized uptake value (SUVmax) compared with the diameters of the lesions. The SUVmax had a decreasing tendency in the first 6 months and, at 6 months post-ablation, FDG accumulation was less affected by inflammatory changes than at 3 months post-RFA. The diameter of the ablated lesion exceeded that of the initial tumor at 3 months post-RFA and shrank to pre-ablation dimensions by 6 months post-RFA. SUVmax was more reliable than the size measurements by CT in the first 6 months after RFA, and PET/CT at 6 months post-RFA may be more appropriate for the assessment of FDG accumulation than that at 3 months post-RFA.

  1. Organic Nanoflowers from a Wide Variety of Molecules Templated by a Hierarchical Supramolecular Scaffold.

    PubMed

    Negrón, Luis M; Díaz, Tanya L; Ortiz-Quiles, Edwin O; Dieppa-Matos, Diómedes; Madera-Soto, Bismark; Rivera, José M

    2016-03-15

    Nanoflowers (NFs) are flowered-shaped particles with overall sizes or features in the nanoscale. Beyond their pleasing aesthetics, NFs have found a number of applications ranging from catalysis, to sensing, to drug delivery. Compared to inorganic based NFs, their organic and hybrid counterparts are relatively underdeveloped mostly because of the lack of a reliable and versatile method for their construction. We report here a method for constructing NFs from a wide variety of biologically relevant molecules (guests), ranging from small molecules, like doxorubicin, to biomacromolecules, like various proteins and plasmid DNA. The method relies on the encapsulation of the guests within a hierarchically structured particle made from supramolecular G-quadruplexes. The size and overall flexibility of the guests dictate the broad morphological features of the resulting NFs, specifically, small and rigid guests favor the formation of NFs with spiky petals, while large and/or flexible guests promote NFs with wide petals. The results from experiments using confocal fluorescence microscopy, and scanning electron microscopy provides the basis for the proposed mechanism for the NF formation.

  2. Rastering strategy for screening and centring of microcrystal samples of human membrane proteins with a sub-10 µm size X-ray synchrotron beam

    PubMed Central

    Cherezov, Vadim; Hanson, Michael A.; Griffith, Mark T.; Hilgart, Mark C.; Sanishvili, Ruslan; Nagarajan, Venugopalan; Stepanov, Sergey; Fischetti, Robert F.; Kuhn, Peter; Stevens, Raymond C.

    2009-01-01

    Crystallization of human membrane proteins in lipidic cubic phase often results in very small but highly ordered crystals. Advent of the sub-10 µm minibeam at the APS GM/CA CAT has enabled the collection of high quality diffraction data from such microcrystals. Herein we describe the challenges and solutions related to growing, manipulating and collecting data from optically invisible microcrystals embedded in an opaque frozen in meso material. Of critical importance is the use of the intense and small synchrotron beam to raster through and locate the crystal sample in an efficient and reliable manner. The resulting diffraction patterns have a significant reduction in background, with strong intensity and improvement in diffraction resolution compared with larger beam sizes. Three high-resolution structures of human G protein-coupled receptors serve as evidence of the utility of these techniques that will likely be useful for future structural determination efforts. We anticipate that further innovations of the technologies applied to microcrystallography will enable the solving of structures of ever more challenging targets. PMID:19535414

  3. Intra- and inter-tester reliability and validity of normal finger size measurement using the Japanese ring gauge system.

    PubMed

    Suzuki, T; Sato, Y; Sotome, S; Arai, H; Arai, A; Yoshida, H

    2017-06-01

    This study was designed to investigate the reliability and validity of measurements of finger diameters with a ring gauge. A reliability study enrolled two independent samples (50 participants and seven examiners in Study I; 26 participants and 26 examiners in Study II). The sizes of each participant's little fingers were measured twice with a ring gauge by each examiner. To investigate the validity of the measurements, five hand therapists compared the finger size and hand volume of 30 participants with the ring gauge and with a figure-of-eight technique (Study III). The intra-class correlation coefficient for intra-observer reliability ranged from 0.97 to 0.99 in Study I, and 0.90 to 0.97 in Study II. The intra-class correlation coefficient for inter-observer reliability was 0.95 in Study I and 0.94 in Study II. The validity study showed a Pearson product moment correlation coefficient of 0.75. The ring gauge showed high reliability and validity for measurement of finger size. III, diagnostic.

  4. Preschool Center Quality and School Readiness: Quality Effects and Variation by Demographic and Child Characteristics

    PubMed Central

    Keys, Tran D.; Farkas, George; Burchinal, Margaret R.; Duncan, Greg J.; Vandell, Deborah L.; Li, Weilin; Ruzek, Erik A.; Howes, Carollee

    2014-01-01

    This article examines associations between observed quality in preschool center classrooms for approximately 6,250 three- to five-year-olds and their school readiness skills at kindergarten entry. Secondary analyses were conducted using data from four large-scale studies to estimate the effects of preschool center quality and interactions between quality and demographic characteristics and child entry skills and behaviors. Findings were summarized across studies using meta-analytic methods. Results indicate small, but statistically significant associations for preschool center quality main effects on language and mathematics outcomes with little evidence of moderation by demographic characteristics or child entry skills and behaviors. Preschool center quality was not reliably related to socioemotional outcomes. The authors discuss possible explanations for the small effect sizes and lack of differential effects. PMID:23331043

  5. “Nanofiltration” Enabled by Super-Absorbent Polymer Beads for Concentrating Microorganisms in Water Samples

    NASA Astrophysics Data System (ADS)

    Xie, Xing; Bahnemann, Janina; Wang, Siwen; Yang, Yang; Hoffmann, Michael R.

    2016-02-01

    Detection and quantification of pathogens in water is critical for the protection of human health and for drinking water safety and security. When the pathogen concentrations are low, large sample volumes (several liters) are needed to achieve reliable quantitative results. However, most microbial identification methods utilize relatively small sample volumes. As a consequence, a concentration step is often required to detect pathogens in natural waters. Herein, we introduce a novel water sample concentration method based on superabsorbent polymer (SAP) beads. When SAP beads swell with water, small molecules can be sorbed within the beads, but larger particles are excluded and, thus, concentrated in the residual non-sorbed water. To illustrate this approach, millimeter-sized poly(acrylamide-co-itaconic acid) (P(AM-co-IA)) beads are synthesized and successfully applied to concentrate water samples containing two model microorganisms: Escherichia coli and bacteriophage MS2. Experimental results indicate that the size of the water channel within water swollen P(AM-co-IA) hydrogel beads is on the order of several nanometers. The millimeter size coupled with a negative surface charge of the beads are shown to be critical in order to achieve high levels of concentration. This new concentration procedure is very fast, effective, scalable, and low-cost with no need for complex instrumentation.

  6. Cholesky-decomposed density MP2 with density fitting: Accurate MP2 and double-hybrid DFT energies for large systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Maurer, Simon A.; Clin, Lucien; Ochsenfeld, Christian, E-mail: christian.ochsenfeld@uni-muenchen.de

    2014-06-14

    Our recently developed QQR-type integral screening is introduced in our Cholesky-decomposed pseudo-densities Møller-Plesset perturbation theory of second order (CDD-MP2) method. We use the resolution-of-the-identity (RI) approximation in combination with efficient integral transformations employing sparse matrix multiplications. The RI-CDD-MP2 method shows an asymptotic cubic scaling behavior with system size and a small prefactor that results in an early crossover to conventional methods for both small and large basis sets. We also explore the use of local fitting approximations which allow to further reduce the scaling behavior for very large systems. The reliability of our method is demonstrated on test sets formore » interaction and reaction energies of medium sized systems and on a diverse selection from our own benchmark set for total energies of larger systems. Timings on DNA systems show that fast calculations for systems with more than 500 atoms are feasible using a single processor core. Parallelization extends the range of accessible system sizes on one computing node with multiple cores to more than 1000 atoms in a double-zeta basis and more than 500 atoms in a triple-zeta basis.« less

  7. "Nanofiltration" Enabled by Super-Absorbent Polymer Beads for Concentrating Microorganisms in Water Samples.

    PubMed

    Xie, Xing; Bahnemann, Janina; Wang, Siwen; Yang, Yang; Hoffmann, Michael R

    2016-02-15

    Detection and quantification of pathogens in water is critical for the protection of human health and for drinking water safety and security. When the pathogen concentrations are low, large sample volumes (several liters) are needed to achieve reliable quantitative results. However, most microbial identification methods utilize relatively small sample volumes. As a consequence, a concentration step is often required to detect pathogens in natural waters. Herein, we introduce a novel water sample concentration method based on superabsorbent polymer (SAP) beads. When SAP beads swell with water, small molecules can be sorbed within the beads, but larger particles are excluded and, thus, concentrated in the residual non-sorbed water. To illustrate this approach, millimeter-sized poly(acrylamide-co-itaconic acid) (P(AM-co-IA)) beads are synthesized and successfully applied to concentrate water samples containing two model microorganisms: Escherichia coli and bacteriophage MS2. Experimental results indicate that the size of the water channel within water swollen P(AM-co-IA) hydrogel beads is on the order of several nanometers. The millimeter size coupled with a negative surface charge of the beads are shown to be critical in order to achieve high levels of concentration. This new concentration procedure is very fast, effective, scalable, and low-cost with no need for complex instrumentation.

  8. “Nanofiltration” Enabled by Super-Absorbent Polymer Beads for Concentrating Microorganisms in Water Samples

    PubMed Central

    Xie, Xing; Bahnemann, Janina; Wang, Siwen; Yang, Yang; Hoffmann, Michael R.

    2016-01-01

    Detection and quantification of pathogens in water is critical for the protection of human health and for drinking water safety and security. When the pathogen concentrations are low, large sample volumes (several liters) are needed to achieve reliable quantitative results. However, most microbial identification methods utilize relatively small sample volumes. As a consequence, a concentration step is often required to detect pathogens in natural waters. Herein, we introduce a novel water sample concentration method based on superabsorbent polymer (SAP) beads. When SAP beads swell with water, small molecules can be sorbed within the beads, but larger particles are excluded and, thus, concentrated in the residual non-sorbed water. To illustrate this approach, millimeter-sized poly(acrylamide-co-itaconic acid) (P(AM-co-IA)) beads are synthesized and successfully applied to concentrate water samples containing two model microorganisms: Escherichia coli and bacteriophage MS2. Experimental results indicate that the size of the water channel within water swollen P(AM-co-IA) hydrogel beads is on the order of several nanometers. The millimeter size coupled with a negative surface charge of the beads are shown to be critical in order to achieve high levels of concentration. This new concentration procedure is very fast, effective, scalable, and low-cost with no need for complex instrumentation. PMID:26876979

  9. Ovarian stem cells are always accompanied by very small embryonic-like stem cells in adult mammalian ovary.

    PubMed

    Bhartiya, Deepa

    2015-11-05

    Existing dogma that a female is born with fixed number of eggs was challenged by the detection of stem cells in adult mammalian ovary. Data has accumulated in support of ovarian stem cells (OSCs) proliferation, maintenance in culture, formation of germ cell nests and differentiation into oocytes and primordial follicle assembly using different strategies. Flow cytometry analysis identified >8 μm OSCs which are DDX1 positive and are considered equivalent to spermatogonial stem cells (SSCs) in testis. Analysis of both ovarian and testicular smears obtained after enzymatic digestion has led to the identification of an additional stem cell population termed very small embryonic-like stem cells (VSELs). VSELs and OSCs/SSCs differ from each other in their size and OCT-4 expression. VSELs express pluripotent markers including nuclear OCT-4 whereas OSCs/SSCs express cytoplasmic OCT-4 suggesting a differentiated state. VSELs can be studied by flow cytometry as small sized cells which are LIN-/CD45-/Sca-1+. We have reported 0.02 ± 0.008, 0.03 ± 0.017 and 0.08 ± 0.03 % of total cells as VSELs in normal, chemoablated and after FSH treatment to chemoablated mouse ovary. VSELs have remained poorly studied till now because of their very small size and rare occurrence. Spinning cells obtained after enzymatic digestion of ovarian tissue at a speed of 1000G (rather than 1200 rpm) throughout processing allows reliable detection of the VSELs by flow cytometry. VSELs exist in aged, chemoablated and non-functional ovary and providing a healthy niche to support their function offers an interesting strategy to manage infertility.

  10. Dosimetric accuracy of a treatment planning system for actively scanned proton beams and small target volumes: Monte Carlo and experimental validation

    NASA Astrophysics Data System (ADS)

    Magro, G.; Molinelli, S.; Mairani, A.; Mirandola, A.; Panizza, D.; Russo, S.; Ferrari, A.; Valvo, F.; Fossati, P.; Ciocca, M.

    2015-09-01

    This study was performed to evaluate the accuracy of a commercial treatment planning system (TPS), in optimising proton pencil beam dose distributions for small targets of different sizes (5-30 mm side) located at increasing depths in water. The TPS analytical algorithm was benchmarked against experimental data and the FLUKA Monte Carlo (MC) code, previously validated for the selected beam-line. We tested the Siemens syngo® TPS plan optimisation module for water cubes fixing the configurable parameters at clinical standards, with homogeneous target coverage to a 2 Gy (RBE) dose prescription as unique goal. Plans were delivered and the dose at each volume centre was measured in water with a calibrated PTW Advanced Markus® chamber. An EBT3® film was also positioned at the phantom entrance window for the acquisition of 2D dose maps. Discrepancies between TPS calculated and MC simulated values were mainly due to the different lateral spread modeling and resulted in being related to the field-to-spot size ratio. The accuracy of the TPS was proved to be clinically acceptable in all cases but very small and shallow volumes. In this contest, the use of MC to validate TPS results proved to be a reliable procedure for pre-treatment plan verification.

  11. Dosimetric accuracy of a treatment planning system for actively scanned proton beams and small target volumes: Monte Carlo and experimental validation.

    PubMed

    Magro, G; Molinelli, S; Mairani, A; Mirandola, A; Panizza, D; Russo, S; Ferrari, A; Valvo, F; Fossati, P; Ciocca, M

    2015-09-07

    This study was performed to evaluate the accuracy of a commercial treatment planning system (TPS), in optimising proton pencil beam dose distributions for small targets of different sizes (5-30 mm side) located at increasing depths in water. The TPS analytical algorithm was benchmarked against experimental data and the FLUKA Monte Carlo (MC) code, previously validated for the selected beam-line. We tested the Siemens syngo(®) TPS plan optimisation module for water cubes fixing the configurable parameters at clinical standards, with homogeneous target coverage to a 2 Gy (RBE) dose prescription as unique goal. Plans were delivered and the dose at each volume centre was measured in water with a calibrated PTW Advanced Markus(®) chamber. An EBT3(®) film was also positioned at the phantom entrance window for the acquisition of 2D dose maps. Discrepancies between TPS calculated and MC simulated values were mainly due to the different lateral spread modeling and resulted in being related to the field-to-spot size ratio. The accuracy of the TPS was proved to be clinically acceptable in all cases but very small and shallow volumes. In this contest, the use of MC to validate TPS results proved to be a reliable procedure for pre-treatment plan verification.

  12. Estimating the size of hidden populations using respondent-driven sampling data: Case examples from Morocco

    PubMed Central

    Johnston, Lisa G; McLaughlin, Katherine R; Rhilani, Houssine El; Latifi, Amina; Toufik, Abdalla; Bennani, Aziza; Alami, Kamal; Elomari, Boutaina; Handcock, Mark S

    2015-01-01

    Background Respondent-driven sampling is used worldwide to estimate the population prevalence of characteristics such as HIV/AIDS and associated risk factors in hard-to-reach populations. Estimating the total size of these populations is of great interest to national and international organizations, however reliable measures of population size often do not exist. Methods Successive Sampling-Population Size Estimation (SS-PSE) along with network size imputation allows population size estimates to be made without relying on separate studies or additional data (as in network scale-up, multiplier and capture-recapture methods), which may be biased. Results Ten population size estimates were calculated for people who inject drugs, female sex workers, men who have sex with other men, and migrants from sub-Sahara Africa in six different cities in Morocco. SS-PSE estimates fell within or very close to the likely values provided by experts and the estimates from previous studies using other methods. Conclusions SS-PSE is an effective method for estimating the size of hard-to-reach populations that leverages important information within respondent-driven sampling studies. The addition of a network size imputation method helps to smooth network sizes allowing for more accurate results. However, caution should be used particularly when there is reason to believe that clustered subgroups may exist within the population of interest or when the sample size is small in relation to the population. PMID:26258908

  13. Construct validity and reliability of a real-time multidimensional smartphone app to assess pain in children and adolescents with cancer.

    PubMed

    Stinson, Jennifer N; Jibb, Lindsay A; Nguyen, Cynthia; Nathan, Paul C; Maloney, Anne Marie; Dupuis, L Lee; Gerstle, J Ted; Hopyan, Sevan; Alman, Benjamin A; Strahlendorf, Caron; Portwine, Carol; Johnston, Donna L

    2015-12-01

    We evaluated the construct validity (including responsiveness), reliability, and feasibility of the Pain Squad multidimensional smartphone-based pain assessment application (app) in children and adolescents with cancer, using 2 descriptive studies with repeated measures. Participants (8-18 years) undergoing cancer treatment were drawn from 4 pediatric cancer centers. In study 1, 92 participants self-reported their level of pain twice daily for 2 weeks using the Pain Squad app to assess app construct validity and reliability. In study 2, 14 participants recorded their level of pain twice a day for 1 week before and 2 weeks after cancer-related surgery to determine app responsiveness. Participants in both studies completed multiple measures to determine the construct validity and feasibility of the Pain Squad app. Correlations between average weekly pain ratings on the Pain Squad app and recalled least, average, and worst weekly pain were moderate to high (0.43-0.68). Correlations with health-related quality of life and pain coping (measured with PedsQL Inventory 4.0, PedsQL Cancer Module, and Pain Coping Questionnaire) were -0.46 to 0.29. The app showed excellent internal consistency (α = 0.96). Pain ratings changed because of surgery with large effect sizes between baseline and the first week postsurgery (>0.85) and small effect sizes between baseline and the second week postsurgery (0.13-0.32). These findings provide evidence of the construct validity, reliability, and feasibility of the Pain Squad app in children and adolescents with cancer. Use of real-time data capture approaches should be considered in future studies of childhood cancer pain. A video accompanying this abstract is available online as Supplemental Digital Content at http://links.lww.com/PAIN/A169.

  14. Advanced Deployable Structural Systems for Small Satellites

    NASA Technical Reports Server (NTRS)

    Belvin, W. Keith; Straubel, Marco; Wilkie, W. Keats; Zander, Martin E.; Fernandez, Juan M.; Hillebrandt, Martin F.

    2016-01-01

    One of the key challenges for small satellites is packaging and reliable deployment of structural booms and arrays used for power, communication, and scientific instruments. The lack of reliable and efficient boom and membrane deployment concepts for small satellites is addressed in this work through a collaborative project between NASA and DLR. The paper provides a state of the art overview on existing spacecraft deployable appendages, the special requirements for small satellites, and initial concepts for deployable booms and arrays needed for various small satellite applications. The goal is to enhance deployable boom predictability and ground testability, develop designs that are tolerant of manufacturing imperfections, and incorporate simple and reliable deployment systems.

  15. Psychometric properties of the Social Phobia and Anxiety Inventory for Children in a Spanish sample.

    PubMed

    Olivares, José; Sánchez-García, Raquel; López-Pina, José Antonio; Rosa-Alcázar, Ana Isabel

    2010-11-01

    The objectives of the present study were to adapt and analyze the factor structure, reliability, and validity of the Social Phobia and Anxiety Inventory for Children (SPAI-C; Beidel, Turner, & Morris, 1995) in a Spanish population. The SPAI-C was applied to a sample of 1588 children and adolescents with ages ranging from 10 to 17 years. The confirmatory factor analysis (CFA) showed a four-factor structure: Public performance, Assertiveness, Fear and avoidance/escape in social encounters, and Cognitive and psychophysiological interferences. Internal consistency was high (.90) and test-retest reliability was moderate (.56). Significant differences were found in the variables sex and age, although the effect size was small in both variables and their interaction. Overall, the increase of the age value was inversely proportional to that of social anxiety measured with the SPAI-C; in participants of the same age, values were higher for girls than for boys. Results suggest that the Social Phobia and Anxiety Inventory For Children is a valid and reliable instrument to assess social anxiety in Spanish children and adolescents.

  16. Reliability considerations for the total strain range version of strainrange partitioning

    NASA Technical Reports Server (NTRS)

    Wirsching, P. H.; Wu, Y. T.

    1984-01-01

    A proposed total strainrange version of strainrange partitioning (SRP) to enhance the manner in which SRP is applied to life prediction is considered with emphasis on how advanced reliability technology can be applied to perform risk analysis and to derive safety check expressions. Uncertainties existing in the design factors associated with life prediction of a component which experiences the combined effects of creep and fatigue can be identified. Examples illustrate how reliability analyses of such a component can be performed when all design factors in the SRP model are random variables reflecting these uncertainties. The Rackwitz-Fiessler and Wu algorithms are used and estimates of the safety index and the probablity of failure are demonstrated for a SRP problem. Methods of analysis of creep-fatigue data with emphasis on procedures for producing synoptic statistics are presented. An attempt to demonstrate the importance of the contribution of the uncertainties associated with small sample sizes (fatique data) to risk estimates is discussed. The procedure for deriving a safety check expression for possible use in a design criteria document is presented.

  17. A preliminary psychometric evaluation of Music in Dementia Assessment Scales (MiDAS).

    PubMed

    McDermott, Orii; Orgeta, Vasiliki; Ridder, Hanne Mette; Orrell, Martin

    2014-06-01

    Music in Dementia Assessment Scales (MiDAS), an observational outcome measure for music therapy with people with moderate to severe dementia, was developed from qualitative data of focus groups and interviews. Expert and peer consultations were conducted at each stage of the scale development to maximize its content validity. This study aimed to evaluate the psychometric properties of MiDAS. Care home residents with dementia attended weekly group music therapy for up to ten sessions. Music therapists and care home staff were requested to complete weekly MiDAS ratings. The Quality of Life Scale (QoL-AD) was completed at three time-points. A total of 629 (staff = 306, therapist = 323) MiDAS forms were completed. The statistical analysis revealed that MiDAS has high therapist inter-rater reliability, low staff inter-rater reliability, adequate staff test-retest reliability, adequate concurrent validity, and good construct validity. High factor loadings between the five MiDAS Visual Analogue Scale (VAS) items, levels of Interest, Response, Initiation, Involvement, and Enjoyment, were found. This study indicates that MiDAS has good psychometric properties despite the small sample size. Future research with a larger sample size could provide a more in-depth psychometric evaluation, including further exploration of the underlying factors. MiDAS provides a measure of engagement with musical experience and offers insight into who is likely to benefit on other outcomes such as quality of life or reduction in psychiatric symptoms.

  18. Reliable detection of fluence anomalies in EPID-based IMRT pretreatment quality assurance using pixel intensity deviations

    PubMed Central

    Gordon, J. J.; Gardner, J. K.; Wang, S.; Siebers, J. V.

    2012-01-01

    Purpose: This work uses repeat images of intensity modulated radiation therapy (IMRT) fields to quantify fluence anomalies (i.e., delivery errors) that can be reliably detected in electronic portal images used for IMRT pretreatment quality assurance. Methods: Repeat images of 11 clinical IMRT fields are acquired on a Varian Trilogy linear accelerator at energies of 6 MV and 18 MV. Acquired images are corrected for output variations and registered to minimize the impact of linear accelerator and electronic portal imaging device (EPID) positioning deviations. Detection studies are performed in which rectangular anomalies of various sizes are inserted into the images. The performance of detection strategies based on pixel intensity deviations (PIDs) and gamma indices is evaluated using receiver operating characteristic analysis. Results: Residual differences between registered images are due to interfraction positional deviations of jaws and multileaf collimator leaves, plus imager noise. Positional deviations produce large intensity differences that degrade anomaly detection. Gradient effects are suppressed in PIDs using gradient scaling. Background noise is suppressed using median filtering. In the majority of images, PID-based detection strategies can reliably detect fluence anomalies of ≥5% in ∼1 mm2 areas and ≥2% in ∼20 mm2 areas. Conclusions: The ability to detect small dose differences (≤2%) depends strongly on the level of background noise. This in turn depends on the accuracy of image registration, the quality of the reference image, and field properties. The longer term aim of this work is to develop accurate and reliable methods of detecting IMRT delivery errors and variations. The ability to resolve small anomalies will allow the accuracy of advanced treatment techniques, such as image guided, adaptive, and arc therapies, to be quantified. PMID:22894421

  19. Sample size requirements for the design of reliability studies: precision consideration.

    PubMed

    Shieh, Gwowen

    2014-09-01

    In multilevel modeling, the intraclass correlation coefficient based on the one-way random-effects model is routinely employed to measure the reliability or degree of resemblance among group members. To facilitate the advocated practice of reporting confidence intervals in future reliability studies, this article presents exact sample size procedures for precise interval estimation of the intraclass correlation coefficient under various allocation and cost structures. Although the suggested approaches do not admit explicit sample size formulas and require special algorithms for carrying out iterative computations, they are more accurate than the closed-form formulas constructed from large-sample approximations with respect to the expected width and assurance probability criteria. This investigation notes the deficiency of existing methods and expands the sample size methodology for the design of reliability studies that have not previously been discussed in the literature.

  20. Activating representations in permanent memory: different benefits for pictures and words.

    PubMed

    Seifert, L S

    1997-09-01

    Previous research has suggested that pictures have privileged access to semantic memory (W. R. Glaser, 1992), but J. Theios and P. C. Amrhein (1989b) argued that prior studies inappropriately used large pictures and small words. In Experiment 1, participants categorized pictures reliably faster than words, even when both types of items were of optimal perceptual size. In Experiment 2, a poststimulus flashmask and judgments about internal features did not eliminate picture superiority, indicating that it was not due to differences in early visual processing or analysis of visible features. In Experiment 3, when participants made judgments about whether items were related, latencies were reliably faster for categorically related pictures than for words, but there was no picture advantage for noncategorically associated items. Results indicate that pictures have privileged access to semantic memory for categories, but that neither pictures nor words seem to have privileged access to noncategorical associations.

  1. Discriminant analysis to predict the occurrence of ELMS in H-mode discharges

    NASA Astrophysics Data System (ADS)

    Kardaun, O. J. W. F.; Itoh, S.-I.; Itoh, K.; Kardaun, J. W. P. F.

    1993-08-01

    After an exposition of its theoretical background, discriminant analysis is applied to the H-mode confinement database to find the region in plasma parameter space in which H-mode with small ELM's (Edge Localized Modes) is likely to occur. The boundary of this region is determined by the condition that the probability of appearance of such a type of H-mode, as a function of the plasma parameters, should be larger than some threshold value and larger than the corresponding probability for other types of H-mode (i.e., H-mode without ELM's or with giant ELM's). In practice, the discrimination has been performed for the ASDEX, JET and JFT-2M tokamaks using four instantaneous plasma parameters (injected power Pinj, magnetic field Bt, plasma current Ip and line averaged electron density ne) and taking also memory effects of the plasma and the distance between the plasma and the wall into account, while using variables that are normalized with respect to machine size. Generally speaking, it is found that there is a substantial overlap between the region of H-mode with small ELM's and the region of the two other types of H-mode. However, the ELM-free and the giant ELM H-modes relatively rarely appear in the region, that, according to the analysis, is allocated to small ELM's. A reliable production of H-mode with only small ELM's seems well possible by choosing this regime in parameter space. In the present study, it was not attempted to arrive at a unified discrimination across the machines. So, projection from one machine to another remains difficult, and a reliable determination of the region where small ELM's occur still requires a training sample from the device under consideration.

  2. Sample size planning for composite reliability coefficients: accuracy in parameter estimation via narrow confidence intervals.

    PubMed

    Terry, Leann; Kelley, Ken

    2012-11-01

    Composite measures play an important role in psychology and related disciplines. Composite measures almost always have error. Correspondingly, it is important to understand the reliability of the scores from any particular composite measure. However, the point estimates of the reliability of composite measures are fallible and thus all such point estimates should be accompanied by a confidence interval. When confidence intervals are wide, there is much uncertainty in the population value of the reliability coefficient. Given the importance of reporting confidence intervals for estimates of reliability, coupled with the undesirability of wide confidence intervals, we develop methods that allow researchers to plan sample size in order to obtain narrow confidence intervals for population reliability coefficients. We first discuss composite reliability coefficients and then provide a discussion on confidence interval formation for the corresponding population value. Using the accuracy in parameter estimation approach, we develop two methods to obtain accurate estimates of reliability by planning sample size. The first method provides a way to plan sample size so that the expected confidence interval width for the population reliability coefficient is sufficiently narrow. The second method ensures that the confidence interval width will be sufficiently narrow with some desired degree of assurance (e.g., 99% assurance that the 95% confidence interval for the population reliability coefficient will be less than W units wide). The effectiveness of our methods was verified with Monte Carlo simulation studies. We demonstrate how to easily implement the methods with easy-to-use and freely available software. ©2011 The British Psychological Society.

  3. Penile Dysmorphic Disorder: Development of a Screening Scale.

    PubMed

    Veale, David; Miles, Sarah; Read, Julie; Troglia, Andrea; Carmona, Lina; Fiorito, Chiara; Wells, Hannah; Wylie, Kevan; Muir, Gordon

    2015-11-01

    Penile dysmorphic disorder (PDD) is shorthand for men diagnosed with body dysmorphic disorder, in whom the size or shape of the penis is their main, if not their exclusive, preoccupation causing significant shame or handicap. There are no specific measures for identifying men with PDD compared to men who are anxious about the size of their penis but do not have PDD. Such a measure might be helpful for treatment planning, reducing unrealistic expectations, and measuring outcome after any psychological or physical intervention. Our aim was, therefore, to validate a specific measure, termed the Cosmetic Procedure Screening Scale for PDD (COPS-P). Eighty-one male participants were divided into three groups: a PDD group (n = 21), a small penis anxiety group (n = 37), and a control group (n = 23). All participants completed the COPS-P as well as standardized measures of depression, anxiety, social phobia, body image, quality of life, and erectile function. Penis size was also measured. The final COPS-P was based on nine items. The scale had good internal reliability and significant convergent validity with measures of related constructs. It discriminated between the PDD group, the small penis anxiety group, and the control group. This is the first study to develop a scale able to discriminate between those with PDD and men anxious about their size who did not have PDD. Clinicians and researchers may use the scale as part of an assessment for men presenting with anxiety about penis size and as an audit or outcome measure after any intervention for this population.

  4. Cluster size dependence of high-order harmonic generation

    NASA Astrophysics Data System (ADS)

    Tao, Y.; Hagmeijer, R.; Bastiaens, H. M. J.; Goh, S. J.; van der Slot, P. J. M.; Biedron, S. G.; Milton, S. V.; Boller, K.-J.

    2017-08-01

    We investigate high-order harmonic generation (HHG) from noble gas clusters in a supersonic gas jet. To identify the contribution of harmonic generation from clusters versus that from gas monomers, we measure the high-order harmonic output over a broad range of the total atomic number density in the jet (from 3×1016 to 3 × 1018 {{cm}}-3) at two different reservoir temperatures (303 and 363 K). For the first time in the evaluation of the harmonic yield in such measurements, the variation of the liquid mass fraction, g, versus pressure and temperature is taken into consideration, which we determine, reliably and consistently, to be below 20% within our range of experimental parameters. By comparing the measured harmonic yield from a thin jet with the calculated corresponding yield from monomers alone, we find an increased emission of the harmonics when the average cluster size is less than 3000. Using g, under the assumption that the emission from monomers and clusters add up coherently, we calculate the ratio of the average single-atom response of an atom within a cluster to that of a monomer and find an enhancement of around 100 for very small average cluster size (∼200). We do not find any dependence of the cut-off frequency on the composition of the cluster jet. This implies that HHG in clusters is based on electrons that return to their parent ions and not to neighboring ions in the cluster. To fully employ the enhanced average single-atom response found for small average cluster sizes (∼200), the nozzle producing the cluster jet must provide a large liquid mass fraction at these small cluster sizes for increasing the harmonic yield. Moreover, cluster jets may allow for quasi-phase matching, as the higher mass of clusters allows for a higher density contrast in spatially structuring the nonlinear medium.

  5. Think locally, act locally: detection of small, medium-sized, and large communities in large networks.

    PubMed

    Jeub, Lucas G S; Balachandran, Prakash; Porter, Mason A; Mucha, Peter J; Mahoney, Michael W

    2015-01-01

    It is common in the study of networks to investigate intermediate-sized (or "meso-scale") features to try to gain an understanding of network structure and function. For example, numerous algorithms have been developed to try to identify "communities," which are typically construed as sets of nodes with denser connections internally than with the remainder of a network. In this paper, we adopt a complementary perspective that communities are associated with bottlenecks of locally biased dynamical processes that begin at seed sets of nodes, and we employ several different community-identification procedures (using diffusion-based and geodesic-based dynamics) to investigate community quality as a function of community size. Using several empirical and synthetic networks, we identify several distinct scenarios for "size-resolved community structure" that can arise in real (and realistic) networks: (1) the best small groups of nodes can be better than the best large groups (for a given formulation of the idea of a good community); (2) the best small groups can have a quality that is comparable to the best medium-sized and large groups; and (3) the best small groups of nodes can be worse than the best large groups. As we discuss in detail, which of these three cases holds for a given network can make an enormous difference when investigating and making claims about network community structure, and it is important to take this into account to obtain reliable downstream conclusions. Depending on which scenario holds, one may or may not be able to successfully identify "good" communities in a given network (and good communities might not even exist for a given community quality measure), the manner in which different small communities fit together to form meso-scale network structures can be very different, and processes such as viral propagation and information diffusion can exhibit very different dynamics. In addition, our results suggest that, for many large realistic networks, the output of locally biased methods that focus on communities that are centered around a given seed node (or set of seed nodes) might have better conceptual grounding and greater practical utility than the output of global community-detection methods. They also illustrate structural properties that are important to consider in the development of better benchmark networks to test methods for community detection.

  6. Think Locally, Act Locally: The Detection of Small, Medium-Sized, and Large Communities in Large Networks

    PubMed Central

    Jeub, Lucas G. S.; Balachandran, Prakash; Porter, Mason A.; Mucha, Peter J.; Mahoney, Michael W.

    2016-01-01

    It is common in the study of networks to investigate intermediate-sized (or “meso-scale”) features to try to gain an understanding of network structure and function. For example, numerous algorithms have been developed to try to identify “communities,” which are typically construed as sets of nodes with denser connections internally than with the remainder of a network. In this paper, we adopt a complementary perspective that “communities” are associated with bottlenecks of locally-biased dynamical processes that begin at seed sets of nodes, and we employ several different community-identification procedures (using diffusion-based and geodesic-based dynamics) to investigate community quality as a function of community size. Using several empirical and synthetic networks, we identify several distinct scenarios for “size-resolved community structure” that can arise in real (and realistic) networks: (i) the best small groups of nodes can be better than the best large groups (for a given formulation of the idea of a good community); (ii) the best small groups can have a quality that is comparable to the best medium-sized and large groups; and (iii) the best small groups of nodes can be worse than the best large groups. As we discuss in detail, which of these three cases holds for a given network can make an enormous difference when investigating and making claims about network community structure, and it is important to take this into account to obtain reliable downstream conclusions. Depending on which scenario holds, one may or may not be able to successfully identify “good” communities in a given network (and good communities might not even exist for a given community quality measure), the manner in which different small communities fit together to form meso-scale network structures can be very different, and processes such as viral propagation and information diffusion can exhibit very different dynamics. In addition, our results suggest that, for many large realistic networks, the output of locally-biased methods that focus on communities that are centered around a given seed node might have better conceptual grounding and greater practical utility than the output of global community-detection methods. They also illustrate subtler structural properties that are important to consider in the development of better benchmark networks to test methods for community detection. PMID:25679670

  7. Think locally, act locally: Detection of small, medium-sized, and large communities in large networks

    NASA Astrophysics Data System (ADS)

    Jeub, Lucas G. S.; Balachandran, Prakash; Porter, Mason A.; Mucha, Peter J.; Mahoney, Michael W.

    2015-01-01

    It is common in the study of networks to investigate intermediate-sized (or "meso-scale") features to try to gain an understanding of network structure and function. For example, numerous algorithms have been developed to try to identify "communities," which are typically construed as sets of nodes with denser connections internally than with the remainder of a network. In this paper, we adopt a complementary perspective that communities are associated with bottlenecks of locally biased dynamical processes that begin at seed sets of nodes, and we employ several different community-identification procedures (using diffusion-based and geodesic-based dynamics) to investigate community quality as a function of community size. Using several empirical and synthetic networks, we identify several distinct scenarios for "size-resolved community structure" that can arise in real (and realistic) networks: (1) the best small groups of nodes can be better than the best large groups (for a given formulation of the idea of a good community); (2) the best small groups can have a quality that is comparable to the best medium-sized and large groups; and (3) the best small groups of nodes can be worse than the best large groups. As we discuss in detail, which of these three cases holds for a given network can make an enormous difference when investigating and making claims about network community structure, and it is important to take this into account to obtain reliable downstream conclusions. Depending on which scenario holds, one may or may not be able to successfully identify "good" communities in a given network (and good communities might not even exist for a given community quality measure), the manner in which different small communities fit together to form meso-scale network structures can be very different, and processes such as viral propagation and information diffusion can exhibit very different dynamics. In addition, our results suggest that, for many large realistic networks, the output of locally biased methods that focus on communities that are centered around a given seed node (or set of seed nodes) might have better conceptual grounding and greater practical utility than the output of global community-detection methods. They also illustrate structural properties that are important to consider in the development of better benchmark networks to test methods for community detection.

  8. Tolerancing aspheres based on manufacturing knowledge

    NASA Astrophysics Data System (ADS)

    Wickenhagen, S.; Kokot, S.; Fuchs, U.

    2017-10-01

    A standard way of tolerancing optical elements or systems is to perform a Monte Carlo based analysis within a common optical design software package. Although, different weightings and distributions are assumed they are all counting on statistics, which usually means several hundreds or thousands of systems for reliable results. Thus, employing these methods for small batch sizes is unreliable, especially when aspheric surfaces are involved. The huge database of asphericon was used to investigate the correlation between the given tolerance values and measured data sets. The resulting probability distributions of these measured data were analyzed aiming for a robust optical tolerancing process.

  9. Tolerancing aspheres based on manufacturing statistics

    NASA Astrophysics Data System (ADS)

    Wickenhagen, S.; Möhl, A.; Fuchs, U.

    2017-11-01

    A standard way of tolerancing optical elements or systems is to perform a Monte Carlo based analysis within a common optical design software package. Although, different weightings and distributions are assumed they are all counting on statistics, which usually means several hundreds or thousands of systems for reliable results. Thus, employing these methods for small batch sizes is unreliable, especially when aspheric surfaces are involved. The huge database of asphericon was used to investigate the correlation between the given tolerance values and measured data sets. The resulting probability distributions of these measured data were analyzed aiming for a robust optical tolerancing process.

  10. Effect of crowd size on patient volume at a large, multipurpose, indoor stadium.

    PubMed

    De Lorenzo, R A; Gray, B C; Bennett, P C; Lamparella, V J

    1989-01-01

    A prediction of patient volume expected at "mass gatherings" is desirable in order to provide optimal on-site emergency medical care. While several methods of predicting patient loads have been suggested, a reliable technique has not been established. This study examines the frequency of medical emergencies at the Syracuse University Carrier Dome, a 50,500-seat indoor stadium. Patient volume and level of care at collegiate basketball and football games as well as rock concerts, over a 7-year period were examined and tabulated. This information was analyzed using simple regression and nonparametric statistical methods to determine level of correlation between crowd size and patient volume. These analyses demonstrated no statistically significant increase in patient volume for increasing crowd size for basketball and football events. There was a small but statistically significant increase in patient volume for increasing crowd size for concerts. A comparison of similar crowd size for each of the three events showed that patient frequency is greatest for concerts and smallest for basketball. The study suggests that crowd size alone has only a minor influence on patient volume at any given event. Structuring medical services based solely on expected crowd size and not considering other influences such as event type and duration may give poor results.

  11. Response trajectories capture the continuous dynamics of the size congruity effect.

    PubMed

    Faulkenberry, Thomas J; Cruise, Alexander; Lavro, Dmitri; Shaki, Samuel

    2016-01-01

    In a comparison task involving numbers, the size congruity effect refers to the general finding that responses are usually faster when there is a match between numerical size and physical size (e.g., 2-8) than when there is a mismatch (e.g., 2-8). In the present study, we used computer mouse tracking to test two competing models of the size congruity effect: an early interaction model, where interference occurs at an early representational stage, and a late interaction model, where interference occurs as dynamic competition between response options. In three experiments, we found that the curvature of responses for incongruent trials was greater than for congruent trials. In Experiment 2 we showed that this curvature effect was reliably modulated by the numerical distance between the two stimulus numbers, with large distance pairs exhibiting a larger curvature effect than small distance pairs. In Experiment 3 we demonstrated that the congruity effects persist into response execution. These findings indicate that incongruities between numerical and physical sizes are carried throughout the response process and result from competition between parallel and partially active response options, lending further support to a late interaction model of the size congruity effect. Copyright © 2015 Elsevier B.V. All rights reserved.

  12. Landscape Simplification Constrains Adult Size in a Native Ground-Nesting Bee

    PubMed Central

    Renauld, Miles; Hutchinson, Alena; Loeb, Gregory; Poveda, Katja; Connelly, Heather

    2016-01-01

    Bees provide critical pollination services to 87% of angiosperm plants; however, the reliability of these services may become threatened as bee populations decline. Agricultural intensification, resulting in the simplification of environments at the landscape scale, greatly changes the quality and quantity of resources available for female bees to provision their offspring. These changes may alter or constrain the tradeoffs in maternal investment allocation between offspring size, number and sex required to maximize fitness. Here we investigate the relationship between landscape scale agricultural intensification and the size and number of individuals within a wild ground nesting bee species, Andrena nasonii. We show that agricultural intensification at the landscape scale was associated with a reduction in the average size of field collected A. nasonii adults in highly agricultural landscapes but not with the number of individuals collected. Small females carried significantly smaller (40%) pollen loads than large females, which is likely to have consequences for subsequent offspring production and fitness. Thus, landscape simplification is likely to constrain allocation of resources to offspring through a reduction in the overall quantity, quality and distribution of resources. PMID:26943127

  13. Landscape Simplification Constrains Adult Size in a Native Ground-Nesting Bee.

    PubMed

    Renauld, Miles; Hutchinson, Alena; Loeb, Gregory; Poveda, Katja; Connelly, Heather

    2016-01-01

    Bees provide critical pollination services to 87% of angiosperm plants; however, the reliability of these services may become threatened as bee populations decline. Agricultural intensification, resulting in the simplification of environments at the landscape scale, greatly changes the quality and quantity of resources available for female bees to provision their offspring. These changes may alter or constrain the tradeoffs in maternal investment allocation between offspring size, number and sex required to maximize fitness. Here we investigate the relationship between landscape scale agricultural intensification and the size and number of individuals within a wild ground nesting bee species, Andrena nasonii. We show that agricultural intensification at the landscape scale was associated with a reduction in the average size of field collected A. nasonii adults in highly agricultural landscapes but not with the number of individuals collected. Small females carried significantly smaller (40%) pollen loads than large females, which is likely to have consequences for subsequent offspring production and fitness. Thus, landscape simplification is likely to constrain allocation of resources to offspring through a reduction in the overall quantity, quality and distribution of resources.

  14. Maximum likelihood techniques applied to quasi-elastic light scattering

    NASA Technical Reports Server (NTRS)

    Edwards, Robert V.

    1992-01-01

    There is a necessity of having an automatic procedure for reliable estimation of the quality of the measurement of particle size from QELS (Quasi-Elastic Light Scattering). Getting the measurement itself, before any error estimates can be made, is a problem because it is obtained by a very indirect measurement of a signal derived from the motion of particles in the system and requires the solution of an inverse problem. The eigenvalue structure of the transform that generates the signal is such that an arbitrarily small amount of noise can obliterate parts of any practical inversion spectrum. This project uses the Maximum Likelihood Estimation (MLE) as a framework to generate a theory and a functioning set of software to oversee the measurement process and extract the particle size information, while at the same time providing error estimates for those measurements. The theory involved verifying a correct form of the covariance matrix for the noise on the measurement and then estimating particle size parameters using a modified histogram approach.

  15. Determining population size of territorial red-winged blackbirds

    USGS Publications Warehouse

    Albers, P.H.

    1976-01-01

    Population sizes of territorial male red-winged blackbirds (Agelaius phoeniceus) were determined with counts of territorial males (area count) and a Petersen-Lincoln Index method for roadsides (roadside estimate). Weather conditions and time of day did not influence either method. Combined roadside estimates had smaller error bounds than the individual transect estimates and were not hindered by the problem of zero recaptures. Roadside estimates were usually one-half as large as the area counts, presumably due to an observer bias for marked birds. The roadside estimate provides only an index of major changes in populations of territorial male redwings. When the roadside estimate is employed, the area count should be used to determine the amount and nature of observer bias. For small population surveys, the area count is probably more reliable and accurate than the roadside estimate.

  16. Repliscan: a tool for classifying replication timing regions.

    PubMed

    Zynda, Gregory J; Song, Jawon; Concia, Lorenzo; Wear, Emily E; Hanley-Bowdoin, Linda; Thompson, William F; Vaughn, Matthew W

    2017-08-07

    Replication timing experiments that use label incorporation and high throughput sequencing produce peaked data similar to ChIP-Seq experiments. However, the differences in experimental design, coverage density, and possible results make traditional ChIP-Seq analysis methods inappropriate for use with replication timing. To accurately detect and classify regions of replication across the genome, we present Repliscan. Repliscan robustly normalizes, automatically removes outlying and uninformative data points, and classifies Repli-seq signals into discrete combinations of replication signatures. The quality control steps and self-fitting methods make Repliscan generally applicable and more robust than previous methods that classify regions based on thresholds. Repliscan is simple and effective to use on organisms with different genome sizes. Even with analysis window sizes as small as 1 kilobase, reliable profiles can be generated with as little as 2.4x coverage.

  17. Heat transfer to small horizontal cylinders immersed in a fluidized bed

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Friedman, J.; Koundakjian, P.; Naylor, D.

    2006-10-15

    Heat transfer to horizontal cylinders immersed in fluidized beds has been extensively studied, but mainly in the context of heat transfer to boiler tubes in coal-fired beds. As a result, most correlations in the literature have been derived for cylinders of 25-50 mm diameter in vigorously fluidizing beds. In recent years, fluidized bed heat treating furnaces fired by natural gas have become increasingly popular, particularly in the steel wire manufacturing industry. These fluidized beds typically operate at relatively low fluidizing rates and with small diameter wires (1-6 mm). Nusselt number correlations developed based on boiler tube studies do not extrapolatemore » down to these small size ranges and low fluidizing rates. In order to obtain reliable Nusselt number data for these size ranges, an experimental investigation has been undertaken using two heat treating fluidized beds; one a pilot-scale industrial unit and the other a lab-scale (300 mm diameter) unit. Heat transfer measurements were obtained using resistively heated cylindrical samples ranging from 1.3 to 9.5 mm in diameter at fluidizing rates ranging from approximately 0.5 x G{sub mf} (packed bed condition) to over 10 x G{sub mf} using aluminum oxide sand particles ranging from d{sub p}=145-330 {mu}m (50-90 grit). It has been found that for all cylinder sizes tested, the Nusselt number reaches a maximum near 2 x G{sub mf}, then remains relatively steady ({+-}5-10%) to the maximum fluidizing rate tested, typically 8-12xG{sub mf}. A correlation for maximum Nusselt number is developed.« less

  18. Effects of composition of grains of debris flow on its impact force

    NASA Astrophysics Data System (ADS)

    Tang, jinbo; Hu, Kaiheng; Cui, Peng

    2017-04-01

    Debris flows compose of solid material with broad size distribution from fine sand to boulders. Impact force imposed by debris flows is a very important issue for protection engineering design and strongly influenced by their grain composition. However, this issue has not been studied in depth and the effects of grain composition not been considered in the calculation of the impact force. In this present study, the small-scale flume experiments with five kinds of compositions of grains for debris flow were carried out to study the effect of the composition of grains of debris flow on its impact force. The results show that the impact force of debris flow increases with the grain size, the hydrodynamic pressure of debris flow is calibrated based on the normalization parameter dmax/d50, in which dmax is the maximum size and d50 is the median size. Furthermore, a log-logistic statistic distribution could be used to describe the distribution of magnitude of impact force of debris flow, where the mean and the variance of the present distribution increase with grain size. This distribution proposed in the present study could be used to the reliability analysis of structures impacted by debris flow.

  19. On the Reliability of Source Time Functions Estimated Using Empirical Green's Function Methods

    NASA Astrophysics Data System (ADS)

    Gallegos, A. C.; Xie, J.; Suarez Salas, L.

    2017-12-01

    The Empirical Green's Function (EGF) method (Hartzell, 1978) has been widely used to extract source time functions (STFs). In this method, seismograms generated by collocated events with different magnitudes are deconvolved. Under a fundamental assumption that the STF of the small event is a delta function, the deconvolved Relative Source Time Function (RSTF) yields the large event's STF. While this assumption can be empirically justified by examination of differences in event size and frequency content of the seismograms, there can be a lack of rigorous justification of the assumption. In practice, a small event might have a finite duration when the RSTF is retrieved and interpreted as the large event STF with a bias. In this study, we rigorously analyze this bias using synthetic waveforms generated by convolving a realistic Green's function waveform with pairs of finite-duration triangular or parabolic STFs. The RSTFs are found using a time-domain based matrix deconvolution. We find when the STFs of smaller events are finite, the RSTFs are a series of narrow non-physical spikes. Interpreting these RSTFs as a series of high-frequency source radiations would be very misleading. The only reliable and unambiguous information we can retrieve from these RSTFs is the difference in durations and the moment ratio of the two STFs. We can apply a Tikhonov smoothing to obtain a single-pulse RSTF, but its duration is dependent on the choice of weighting, which may be subjective. We then test the Multi-Channel Deconvolution (MCD) method (Plourde & Bostock, 2017) which assumes that both STFs have finite durations to be solved for. A concern about the MCD method is that the number of unknown parameters is larger, which would tend to make the problem rank-deficient. Because the kernel matrix is dependent on the STFs to be solved for under a positivity constraint, we can only estimate the rank-deficiency with a semi-empirical approach. Based on the results so far, we find that the rank-deficiency makes it improbable to solve for both STFs. To solve for the larger STF we need to assume the shape of the small STF to be known a priori. Thus, the reliability of the estimated large STF depends on the difference between the assumed and true shapes of the small STF. We will show how the reliability varies with realistic scenarios.

  20. Stereo Correspondence Using Moment Invariants

    NASA Astrophysics Data System (ADS)

    Premaratne, Prashan; Safaei, Farzad

    Autonomous navigation is seen as a vital tool in harnessing the enormous potential of Unmanned Aerial Vehicles (UAV) and small robotic vehicles for both military and civilian use. Even though, laser based scanning solutions for Simultaneous Location And Mapping (SLAM) is considered as the most reliable for depth estimation, they are not feasible for use in UAV and land-based small vehicles due to their physical size and weight. Stereovision is considered as the best approach for any autonomous navigation solution as stereo rigs are considered to be lightweight and inexpensive. However, stereoscopy which estimates the depth information through pairs of stereo images can still be computationally expensive and unreliable. This is mainly due to some of the algorithms used in successful stereovision solutions require high computational requirements that cannot be met by small robotic vehicles. In our research, we implement a feature-based stereovision solution using moment invariants as a metric to find corresponding regions in image pairs that will reduce the computational complexity and improve the accuracy of the disparity measures that will be significant for the use in UAVs and in small robotic vehicles.

  1. Mandala Networks: ultra-small-world and highly sparse graphs

    PubMed Central

    Sampaio Filho, Cesar I. N.; Moreira, André A.; Andrade, Roberto F. S.; Herrmann, Hans J.; Andrade, José S.

    2015-01-01

    The increasing demands in security and reliability of infrastructures call for the optimal design of their embedded complex networks topologies. The following question then arises: what is the optimal layout to fulfill best all the demands? Here we present a general solution for this problem with scale-free networks, like the Internet and airline networks. Precisely, we disclose a way to systematically construct networks which are robust against random failures. Furthermore, as the size of the network increases, its shortest path becomes asymptotically invariant and the density of links goes to zero, making it ultra-small world and highly sparse, respectively. The first property is ideal for communication and navigation purposes, while the second is interesting economically. Finally, we show that some simple changes on the original network formulation can lead to an improved topology against malicious attacks. PMID:25765450

  2. Wave transmission approach based on modal analysis for embedded mechanical systems

    NASA Astrophysics Data System (ADS)

    Cretu, Nicolae; Nita, Gelu; Ioan Pop, Mihail

    2013-09-01

    An experimental method for determining the phase velocity in small solid samples is proposed. The method is based on measuring the resonant frequencies of a binary or ternary solid elastic system comprising the small sample of interest and a gauge material of manageable size. The wave transmission matrix of the combined system is derived and the theoretical values of its eigenvalues are used to determine the expected eigenfrequencies that, equated with the measured values, allow for the numerical estimation of the phase velocities in both materials. The known phase velocity of the gauge material is then used to asses the accuracy of the method. Using computer simulation and the experimental values for phase velocities, the theoretical values for the eigenfrequencies of the eigenmodes of the embedded elastic system are obtained, to validate the method. We conclude that the proposed experimental method may be reliably used to determine the elastic properties of small solid samples whose geometries do not allow a direct measurement of their resonant frequencies.

  3. Design of 2.5 GHz broad bandwidth microwave bandpass filter at operating frequency of 10 GHz using HFSS

    NASA Astrophysics Data System (ADS)

    Jasim, S. E.; Jusoh, M. A.; Mahmud, S. N. S.; Zamani, A. H.

    2018-04-01

    Development of low losses, small size and broad bandwidth microwave bandpass filter operating at higher frequencies is an active area of research. This paper presents a new route used to design and simulate microwave bandpass filter using finite element modelling and realized broad bandwidth, low losses, small dimension microwave bandpass filter operating at 10 GHz frequency using return loss method. The filter circuit has been carried out using Computer Aid Design (CAD), Ansoft HFSS software and designed with four parallel couple line model and small dimension (10 × 10 mm2) using LaAlO3 substrate. The response of the microwave filter circuit showed high return loss -50 dB at operating frequency at 10.4 GHz and broad bandwidth of 2.5 GHz from 9.5 to 12 GHz. The results indicate the filter design and simulation using HFSS is reliable and have the opportunity to transfer from lab potential experiments to the industry.

  4. Small genomes and large seeds: chromosome numbers, genome size and seed mass in diploid Aesculus species (Sapindaceae)

    PubMed Central

    Krahulcová, Anna; Trávníček, Pavel; Rejmánek, Marcel

    2017-01-01

    Background and Aims Aesculus L. (horse chestnut, buckeye) is a genus of 12–19 extant woody species native to the temperate Northern Hemisphere. This genus is known for unusually large seeds among angiosperms. While chromosome counts are available for many Aesculus species, only one has had its genome size measured. The aim of this study is to provide more genome size data and analyse the relationship between genome size and seed mass in this genus. Methods Chromosome numbers in root tip cuttings were confirmed for four species and reported for the first time for three additional species. Flow cytometric measurements of 2C nuclear DNA values were conducted on eight species, and mean seed mass values were estimated for the same taxa. Key Results The same chromosome number, 2n = 40, was determined in all investigated taxa. Original measurements of 2C values for seven Aesculus species (eight taxa), added to just one reliable datum for A. hippocastanum, confirmed the notion that the genome size in this genus with relatively large seeds is surprisingly low, ranging from 0·955 pg 2C–1 in A. parviflora to 1·275 pg 2C–1 in A. glabra var. glabra. Conclusions The chromosome number of 2n = 40 seems to be conclusively the universal 2n number for non-hybrid species in this genus. Aesculus genome sizes are relatively small, not only within its own family, Sapindaceae, but also within woody angiosperms. The genome sizes seem to be distinct and non-overlapping among the four major Aesculus clades. These results provide an extra support for the most recent reconstruction of Aesculus phylogeny. The correlation between the 2C values and seed masses in examined Aesculus species is slightly negative and not significant. However, when the four major clades are treated separately, there is consistent positive association between larger genome size and larger seed mass within individual lineages. PMID:28065925

  5. The pathophysiology of chronic thromboembolic pulmonary hypertension.

    PubMed

    Simonneau, Gérald; Torbicki, Adam; Dorfmüller, Peter; Kim, Nick

    2017-03-31

    Chronic thromboembolic pulmonary hypertension (CTEPH) is a rare, progressive pulmonary vascular disease that is usually a consequence of prior acute pulmonary embolism. CTEPH usually begins with persistent obstruction of large and/or middle-sized pulmonary arteries by organised thrombi. Failure of thrombi to resolve may be related to abnormal fibrinolysis or underlying haematological or autoimmune disorders. It is now known that small-vessel abnormalities also contribute to haemodynamic compromise, functional impairment and disease progression in CTEPH. Small-vessel disease can occur in obstructed areas, possibly triggered by unresolved thrombotic material, and downstream from occlusions, possibly because of excessive collateral blood supply from high-pressure bronchial and systemic arteries. The molecular processes underlying small-vessel disease are not completely understood and further research is needed in this area. The degree of small-vessel disease has a substantial impact on the severity of CTEPH and postsurgical outcomes. Interventional and medical treatment of CTEPH should aim to restore normal flow distribution within the pulmonary vasculature, unload the right ventricle and prevent or treat small-vessel disease. It requires early, reliable identification of patients with CTEPH and use of optimal treatment modalities in expert centres. Copyright ©ERS 2017.

  6. Reliable jitter and shimmer measurements in voice clinics: the relevance of vowel, gender, vocal intensity, and fundamental frequency effects in a typical clinical task.

    PubMed

    Brockmann, Meike; Drinnan, Michael J; Storck, Claudio; Carding, Paul N

    2011-01-01

    The aims of this study were to examine vowel and gender effects on jitter and shimmer in a typical clinical voice task while correcting for the confounding effects of voice sound pressure level (SPL) and fundamental frequency (F(0)). Furthermore the relative effect sizes of vowel, gender, voice SPL, and F(0) were assessed, and recommendations for clinical measurements were derived. With this cross-sectional single cohort study, 57 healthy adults (28 women, 29 men) aged 20-40 years were investigated. Three phonations of /a/, /o/, and /i/ at "normal" voice loudness were analyzed using Praat (software). The effects of vowel, gender, voice SPL, and F(0) on jitter and shimmer were assessed using descriptive and inferential (analysis of covariance) statistics. The effect sizes were determined with the eta-squared statistic. Vowels, gender, voice SPL, and F(0), each had significant effects either on jitter or on shimmer, or both. Voice SPL was the most important factor, whereas vowel, gender, and F(0) effects were comparatively small. Because men had systematically higher voice SPL, the gender effects on jitter and shimmer were smaller when correcting for SPL and F(0). Surprisingly, in clinical assessments, voice SPL has the single biggest impact on jitter and shimmer. Vowel and gender effects were clinically important, whereas fundamental frequency had a relatively small influence. Phonations at a predefined voice SPL (80 dB minimum) and vowel (/a/) would enhance measurement reliability. Furthermore, gender-specific thresholds applying these guidelines should be established. However, the efficiency of these measures should be verified and tested with patients. Copyright © 2011 The Voice Foundation. All rights reserved.

  7. System reliability analysis of granular filter for protection against piping in dams

    NASA Astrophysics Data System (ADS)

    Srivastava, A.; Sivakumar Babu, G. L.

    2015-09-01

    Granular filters are provided for the safety of water retaining structure for protection against piping failure. The phenomenon of piping triggers when the base soil to be protected starts migrating in the direction of seepage flow under the influence of seepage force. To protect base soil from migration, the voids in the filter media should be small enough but it should not also be too small to block smooth passage of seeping water. Fulfilling these two contradictory design requirements at the same time is a major concern for the successful performance of granular filter media. Since Terzaghi era, conventionally, particle size distribution (PSD) of granular filters is designed based on particle size distribution characteristics of the base soil to be protected. The design approach provides a range of D15f value in which the PSD of granular filter media should fall and there exist infinite possibilities. Further, safety against the two critical design requirements cannot be ensured. Although used successfully for many decades, the existing filter design guidelines are purely empirical in nature accompanied with experience and good engineering judgment. In the present study, analytical solutions for obtaining the factor of safety with respect to base soil particle migration and soil permeability consideration as proposed by the authors are first discussed. The solution takes into consideration the basic geotechnical properties of base soil and filter media as well as existing hydraulic conditions and provides a comprehensive solution to the granular filter design with ability to assess the stability in terms of factor of safety. Considering the fact that geotechnical properties are variable in nature, probabilistic analysis is further suggested to evaluate the system reliability of the filter media that may help in risk assessment and risk management for decision making.

  8. ORDEM 3.0 and MASTER-2009 Modeled Small Debris Population Comparison

    NASA Technical Reports Server (NTRS)

    Krisko, P. H.; Flegel, S.

    2014-01-01

    The latest versions of the two premier orbital debris engineering models, NASA's ORDEM 3.0 and ESA's MASTER-2009, have been publically released. Both models have gone through significant advancements since inception, and now represent the state-of-the-art in orbital debris knowledge of their respective agencies. The purpose of these models is to provide satellite designers/operators and debris researchers with reliable estimates of the artificial debris environment in low Earth orbit (LEO) to geosynchronous orbit (GEO). The small debris environment within the size range of 1 mm to 1 cm is of particular interest to both human and robotic spacecraft programs, particularly in LEO. These objects are much more numerous than larger trackable debris and can have enough momentum to cause significant, if not catastrophic, damage to spacecraft upon impact. They are also small enough to elude routine detection by existing observation systems (radar and telescope). Without reliable detection the modeling of these populations has always coupled theoretical origins with supporting observational data in different degrees. In this paper, we present and detail the 1 mm to 1 cm orbital debris populations from both ORDEM 3.0 and MASTER-2009 in LEO. We review population categories: particle sources for MASTER-2009, particle densities for ORDEM 3.0. We describe data sources and their uses, and supporting models. Fluxes on spacecraft for chosen orbits are also presented and discussed within the context of each model.

  9. Müller-Lyer figures influence the online reorganization of visually guided grasping movements.

    PubMed

    Heath, Matthew; Rival, Christina; Neely, Kristina; Krigolson, Olav

    2006-03-01

    In advance of grasping a visual object embedded within fins-in and fins-out Müller-Lyer (ML) configurations, participants formulated a premovement grip aperture (GA) based on the size of a neutral preview object. Preview objects were smaller, veridical, or larger than the size of the to-be-grasped target object. As a result, premovement GA associated with the small and large preview objects required significant online reorganization to appropriately grasp the target object. We reasoned that such a manipulation would provide an opportunity to examine the extent to which the visuomotor system engages egocentric and/or allocentric visual cues for the online, feedback-based control of action. It was found that the online reorganization of GA was reliably influenced by the ML figures (i.e., from 20 to 80% of movement time), regardless of the size of the preview object, albeit the small and large preview objects elicited more robust illusory effects than the veridical preview object. These results counter the view that online grasping control is mediated by absolute visual information computed with respect to the observer (e.g., Glover in Behav Brain Sci 27:3-78, 2004; Milner and Goodale in The visual brain in action 1995). Instead, the impact of the ML figures suggests a level of interaction between egocentric and allocentric visual cues in online action control.

  10. Ravens, New Caledonian crows and jackdaws parallel great apes in motor self-regulation despite smaller brains.

    PubMed

    Kabadayi, Can; Taylor, Lucy A; von Bayern, Auguste M P; Osvath, Mathias

    2016-04-01

    Overriding motor impulses instigated by salient perceptual stimuli represent a fundamental inhibitory skill. Such motor self-regulation facilitates more rational behaviour, as it brings economy into the bodily interaction with the physical and social world. It also underlies certain complex cognitive processes including decision making. Recently, MacLean et al. (MacLean et al. 2014 Proc. Natl Acad. Sci. USA 111, 2140-2148. (doi:10.1073/pnas.1323533111)) conducted a large-scale study involving 36 species, comparing motor self-regulation across taxa. They concluded that absolute brain size predicts level of performance. The great apes were most successful. Only a few of the species tested were birds. Given birds' small brain size-in absolute terms-yet flexible behaviour, their motor self-regulation calls for closer study. Corvids exhibit some of the largest relative avian brain sizes-although small in absolute measure-as well as the most flexible cognition in the animal kingdom. We therefore tested ravens, New Caledonian crows and jackdaws in the so-called cylinder task. We found performance indistinguishable from that of great apes despite the much smaller brains. We found both absolute and relative brain volume to be a reliable predictor of performance within Aves. The complex cognition of corvids is often likened to that of great apes; our results show further that they share similar fundamental cognitive mechanisms.

  11. Tract Sizes in Miniaturized Percutaneous Nephrolithotomy: A Systematic Review from the European Association of Urology Urolithiasis Guidelines Panel.

    PubMed

    Ruhayel, Yasir; Tepeler, Abdulkadir; Dabestani, Saeed; MacLennan, Steven; Petřík, Aleš; Sarica, Kemal; Seitz, Christian; Skolarikos, Andreas; Straub, Michael; Türk, Christian; Yuan, Yuhong; Knoll, Thomas

    2017-08-01

    Miniaturized instruments for percutaneous nephrolithotomy (PNL), utilizing tracts sized ≤22 Fr, have been developed in an effort to reduce the morbidity and increase the efficiency of stone removal compared with standard PNL (>22 Fr). We systematically reviewed all available evidence on the efficacy and safety of miniaturized PNL for removing renal calculi. The review was performed according to the Preferred Reporting Items for Systematic Reviews and Meta-analyses statement. Since it was not possible to perform a meta-analysis, the data were summarized in a narrative synthesis. After screening 2945 abstracts, 18 studies were included (two randomized controlled trials [RCTs], six nonrandomized comparative studies, and 10 case series). Thirteen studies were full-text articles and five were only available as congress abstracts. The size of tracts used in miniaturized procedures ranged from 22 Fr to 4.8 Fr. The largest mean stone size treated using small instruments was 980mm 2 . Stone-free rates were comparable in miniaturized and standard PNL procedures. Procedures performed with small instruments tended to be associated with significantly lower blood loss, while the procedure duration tended to be significantly longer. Other complications were not notably different between PNL types. Study designs and populations were heterogeneous. Study limitations included selection and outcome reporting bias, as well as a lack of information on relevant confounding factors. The studies suggest that miniaturized PNL is at least as efficacious and safe as standard PNL for the removal of renal calculi. However, the quality of the evidence was poor, drawn mainly from small studies, the majority of which were single-arm case series, and only two of which were RCTs. Furthermore, the tract sizes used and types of stones treated were heterogeneous. Hence, the risks of bias and confounding were high, highlighting the need for more reliable data from RCTs. Removing kidney stones via percutaneous nephrolithotomy (PNL) using smaller sized instruments (mini-PNL) appears to be as effective and safe as using larger (traditional) instruments, but more clinical research is needed. Copyright © 2017 European Association of Urology. Published by Elsevier B.V. All rights reserved.

  12. Functional Genomics in the Study of Mind-Body Therapies

    PubMed Central

    Niles, Halsey; Mehta, Darshan H.; Corrigan, Alexandra A.; Bhasin, Manoj K.; Denninger, John W.

    2014-01-01

    Background Mind-body therapies (MBTs) are used throughout the world in treatment, disease prevention, and health promotion. However, the mechanisms by which MBTs exert their positive effects are not well understood. Investigations into MBTs using functional genomics have revolutionized the understanding of MBT mechanisms and their effects on human physiology. Methods We searched the literature for the effects of MBTs on functional genomics determinants using MEDLINE, supplemented by a manual search of additional journals and a reference list review. Results We reviewed 15 trials that measured global or targeted transcriptomic, epigenomic, or proteomic changes in peripheral blood. Sample sizes ranged from small pilot studies (n=2) to large trials (n=500). While the reliability of individual genes from trial to trial was often inconsistent, genes related to inflammatory response, particularly those involved in the nuclear factor-kappa B (NF-κB) pathway, were consistently downregulated across most studies. Conclusion In general, existing trials focusing on gene expression changes brought about by MBTs have revealed intriguing connections to the immune system through the NF-κB cascade, to telomere maintenance, and to apoptotic regulation. However, these findings are limited to a small number of trials and relatively small sample sizes. More rigorous randomized controlled trials of healthy subjects and specific disease states are warranted. Future research should investigate functional genomics areas both upstream and downstream of MBT-related gene expression changes—from epigenomics to proteomics and metabolomics. PMID:25598735

  13. Functional genomics in the study of mind-body therapies.

    PubMed

    Niles, Halsey; Mehta, Darshan H; Corrigan, Alexandra A; Bhasin, Manoj K; Denninger, John W

    2014-01-01

    Mind-body therapies (MBTs) are used throughout the world in treatment, disease prevention, and health promotion. However, the mechanisms by which MBTs exert their positive effects are not well understood. Investigations into MBTs using functional genomics have revolutionized the understanding of MBT mechanisms and their effects on human physiology. We searched the literature for the effects of MBTs on functional genomics determinants using MEDLINE, supplemented by a manual search of additional journals and a reference list review. We reviewed 15 trials that measured global or targeted transcriptomic, epigenomic, or proteomic changes in peripheral blood. Sample sizes ranged from small pilot studies (n=2) to large trials (n=500). While the reliability of individual genes from trial to trial was often inconsistent, genes related to inflammatory response, particularly those involved in the nuclear factor-kappa B (NF-κB) pathway, were consistently downregulated across most studies. In general, existing trials focusing on gene expression changes brought about by MBTs have revealed intriguing connections to the immune system through the NF-κB cascade, to telomere maintenance, and to apoptotic regulation. However, these findings are limited to a small number of trials and relatively small sample sizes. More rigorous randomized controlled trials of healthy subjects and specific disease states are warranted. Future research should investigate functional genomics areas both upstream and downstream of MBT-related gene expression changes-from epigenomics to proteomics and metabolomics.

  14. [Detection and evaluation of cartilage defects in the canine stifle joint - an ex vivo study using high-field magnetic resonance imaging].

    PubMed

    Flatz, K M; Glaser, C; Flatz, W H; Reiser, M F; Matis, U

    2014-01-01

    The aim of our study was to implement and test an imaging protocol for the detection and evaluation of standardised cartilage defects using high-field magnetic resonance imaging (MRI) and to determine its limitations. A total of 84 cartilage defects were created in the femoral condyles of euthanized dogs with a minimum body mass of 25 kg. The cartilage defects had a depth of 0.3 to 1.0 mm and a diameter of 1 to 5 mm. T1-FLASH-3D-WE-sequences with an isotropic voxel size of 0.5 x 0.5 x 0.5 mm and an anisotropic voxel size of 0.3 x 0.3 x 0.8 mm were used. In addition to quantitative evaluation of the cartilage defects, the sig- nal intensities, signal-to-noise ratios and contrast-to-noise ratios of the cartilage were determined. Of special interest were the limita- tions in identifying and delineating the standardised cartilage defects. With the anisotropic voxel size, more cartilage defects were detectable. Our results demonstrated that cartilage defects as small as 3.0 mm in diameter and 0.4 mm in depth were reliably detected using anisotropic settings. Cartilage defects below this size were not reliably detected. We found that for optimal delineation of the joint cartilage and associated defects, a higher in-plane resolution with a larger slice thickness should be used, corresponding to the anisotropic settings employed in this study. For the delineation of larger cartilage defects, both the anisotropic and isotropic imaging methods can be used.

  15. Does Self-Control Training Improve Self-Control? A Meta-Analysis.

    PubMed

    Friese, Malte; Frankenbach, Julius; Job, Veronika; Loschelder, David D

    2017-11-01

    Self-control is positively associated with a host of beneficial outcomes. Therefore, psychological interventions that reliably improve self-control are of great societal value. A prominent idea suggests that training self-control by repeatedly overriding dominant responses should lead to broad improvements in self-control over time. Here, we conducted a random-effects meta-analysis based on robust variance estimation of the published and unpublished literature on self-control training effects. Results based on 33 studies and 158 effect sizes revealed a small-to-medium effect of g = 0.30, confidence interval (CI 95 ) [0.17, 0.42]. Moderator analyses found that training effects tended to be larger for (a) self-control stamina rather than strength, (b) studies with inactive compared to active control groups, (c) males than females, and (d) when proponents of the strength model of self-control were (co)authors of a study. Bias-correction techniques suggested the presence of small-study effects and/or publication bias and arrived at smaller effect size estimates (range: g corrected = .13 to .24). The mechanisms underlying the effect are poorly understood. There is not enough evidence to conclude that the repeated control of dominant responses is the critical element driving training effects.

  16. High Resolution Eddy-Current Wire Testing Based on a Gmr Sensor-Array

    NASA Astrophysics Data System (ADS)

    Kreutzbruck, Marc; Allweins, Kai; Strackbein, Chris; Bernau, Hendrick

    2009-03-01

    Increasing demands in materials quality and cost effectiveness have led to advanced standards in manufacturing technology. Especially when dealing with high quality standards in conjunction with high throughput quantitative NDE techniques are vital to provide reliable and fast quality control systems. In this work we illuminate a modern electromagnetic NDE approach using a small GMR sensor array for testing superconducting wires. Four GMR sensors are positioned around the wire. Each GMR sensor provides a field sensitivity of 200 pT/√Hz and a spatial resolution of about 100 μm. This enables us to detect under surface defects of 100 μm in size in a depth of 200 μm with a signal-to-noise ratio of better than 400. Surface defects could be detected with a SNR of up to 10,000. Besides this remarkably SNR the small extent of GMR sensors results in a spatial resolution which offers new visualisation techniques for defect localisation, defect characterization and tomography-like mapping techniques. We also report on inverse algorithms based on either a Finite Element Method or an analytical approach. These allow for accurate defect localization on the urn scale and an estimation of the defect size.

  17. Behaviour of Arctic charr Salvelinus alpinus during an induced mating season in captivity: how male relative size influences male behavioural investment and female preference over time.

    PubMed

    Bolgan, M; O'Brien, J; Picciulin, M; Manning, L; Gammell, M

    2017-04-01

    The behaviour of sexually mature Arctic charr Salvelinus alpinus specimens (fifth farm generation) was observed in captivity for four consecutive days. Only agonistic interactions between males of different size were facilitated on the first 2 days, while both agonistic and courtship interactions were possible from the third day up to the end of the experiment. The reliability of behavioural analysis was assessed in order to reduce the possibility of observer errors within the generated datasets. The behavioural investment of big males, small males and females was analysed using general linear models (two-way repeated measures ANOVAs with time and male size as factors). A peak in the agonistic interactions between males occurred during the first day of interactions, where the agonistic investment of big males was significantly higher than that of small males. This resulted in an increased investment in submissive behaviour by the small males, who consistently performed submissive behaviours from the second day of interactions up to the end of the trial. Big males were found to invest significantly more than small males in courtship behaviours for the duration of the trial. Even though females performed inter-sexual behaviours towards both big and small males for the entire observation period, female interaction rate towards big males was higher than towards small males. This study suggests that both male investment in mating behaviour and female preference might be related to male characteristics such as body length and that S. alpinus behavioural patterns and mate choice cues might be strongly context-related and characterized by high levels of behavioural plasticity (i.e. presence-absence of certain behavioural units or potential reversal of a mate choice cue) within the same species. Finally, in light of this, some conservation measures are discussed. In particular, effective management plans should take into account the high level of behavioural plasticity likely to be occurring in this species. © 2016 The Fisheries Society of the British Isles.

  18. MEMS for pico- to micro-satellites

    NASA Astrophysics Data System (ADS)

    Shea, H. R.

    2009-02-01

    MEMS sensors, actuators, and sub-systems can enable an important reduction in the size and mass of spacecrafts, first by replacing larger and heavier components, then by replacing entire subsystems, and finally by enabling the microfabrication of highly integrated picosats. Very small satellites (1 to 100 kg) stand to benefit the most from MEMS technologies. These small satellites are typically used for science or technology demonstration missions, with higher risk tolerance than multi-ton telecommunication satellites. While MEMS are playing a growing role on Earth in safety-critical applications, in the harsh and remote environment of space, reliability is still the crucial issue, and the absence of an accepted qualification methodology is holding back MEMS from wider use. An overview is given of the range of MEMS applications in space. An effective way to prove that MEMS can operate reliably in space is to use them in space: we illustrate how Cubesats (1 kg, 1 liter, cubic satellites in a standardized format to reduce launch costs) can serve as low-cost vectors for MEMS technology demonstration in space. The Cubesat SwissCube developed in Switzerland is used as one example of a rapid way to fly new microtechnologies, and also as an example of a spacecraft whose performance is only possible thanks to MEMS.

  19. Test-retest reliability of jump execution variables using mechanography: a comparison of jump protocols.

    PubMed

    Fitzgerald, John S; Johnson, LuAnn; Tomkinson, Grant; Stein, Jesse; Roemmich, James N

    2018-05-01

    Mechanography during the vertical jump may enhance screening and determining mechanistic causes underlying physical performance changes. Utility of jump mechanography for evaluation is limited by scant test-retest reliability data on force-time variables. This study examined the test-retest reliability of eight jump execution variables assessed from mechanography. Thirty-two women (mean±SD: age 20.8 ± 1.3 yr) and 16 men (age 22.1 ± 1.9 yr) attended a familiarization session and two testing sessions, all one week apart. Participants performed two variations of the squat jump with squat depth self-selected and controlled using a goniometer to 80º knee flexion. Test-retest reliability was quantified as the systematic error (using effect size between jumps), random error (using coefficients of variation), and test-retest correlations (using intra-class correlation coefficients). Overall, jump execution variables demonstrated acceptable reliability, evidenced by small systematic errors (mean±95%CI: 0.2 ± 0.07), moderate random errors (mean±95%CI: 17.8 ± 3.7%), and very strong test-retest correlations (range: 0.73-0.97). Differences in random errors between controlled and self-selected protocols were negligible (mean±95%CI: 1.3 ± 2.3%). Jump execution variables demonstrated acceptable reliability, with no meaningful differences between the controlled and self-selected jump protocols. To simplify testing, a self-selected jump protocol can be used to assess force-time variables with negligible impact on measurement error.

  20. MEASUREMENT: ACCOUNTING FOR RELIABILITY IN PERFORMANCE ESTIMATES.

    PubMed

    Waterman, Brian; Sutter, Robert; Burroughs, Thomas; Dunagan, W Claiborne

    2014-01-01

    When evaluating physician performance measures, physician leaders are faced with the quandary of determining whether departures from expected physician performance measurements represent a true signal or random error. This uncertainty impedes the physician leader's ability and confidence to take appropriate performance improvement actions based on physician performance measurements. Incorporating reliability adjustment into physician performance measurement is a valuable way of reducing the impact of random error in the measurements, such as those caused by small sample sizes. Consequently, the physician executive has more confidence that the results represent true performance and is positioned to make better physician performance improvement decisions. Applying reliability adjustment to physician-level performance data is relatively new. As others have noted previously, it's important to keep in mind that reliability adjustment adds significant complexity to the production, interpretation and utilization of results. Furthermore, the methods explored in this case study only scratch the surface of the range of available Bayesian methods that can be used for reliability adjustment; further study is needed to test and compare these methods in practice and to examine important extensions for handling specialty-specific concerns (e.g., average case volumes, which have been shown to be important in cardiac surgery outcomes). Moreover, it's important to note that the provider group average as a basis for shrinkage is one of several possible choices that could be employed in practice and deserves further exploration in future research. With these caveats, our results demonstrate that incorporating reliability adjustment into physician performance measurements is feasible and can notably reduce the incidence of "real" signals relative to what one would expect to see using more traditional approaches. A physician leader who is interested in catalyzing performance improvement through focused, effective physician performance improvement is well advised to consider the value of incorporating reliability adjustments into their performance measurement system.

  1. Near-Earth-object survey progress and population of small near-Earth asteroids

    NASA Astrophysics Data System (ADS)

    Harris, A.

    2014-07-01

    Estimating the total population vs. size of NEAs and the completion of surveys is the same thing since the total population is just the number discovered divided by the estimated completion. I review the method of completion estimation based on ratio of re-detected objects to total detections (known plus new discoveries). The method is quite general and can be used for population estimations of all sorts, from wildlife to various classes of solar system bodies. Since 2001, I have been making estimates of population and survey progress approximately every two years. Plotted below, left, is my latest estimate, including NEA discoveries up to August, 2012. I plan to present an update at the meeting. All asteroids of a given size are not equally easy to detect because of specific orbital geometries. Thus a model of the orbital distribution is necessary, and computer simulations using those orbits need to establish the relation between the raw re-detection ratio and the actual completion fraction. This can be done for any sub-group population, allowing to estimate the population of a subgroup and the expected current completion. Once a reliable survey computer model has been developed and ''calibrated'' with respect to actual survey re-detections versus size, it can be extrapolated to smaller sizes to estimate completion even at very small size where re-detections are rare or even zero. I have recently investigated the subgroup of extremely low encounter velocity NEAs, the class of interest for the Asteroid Redirect Mission (ARM), recently proposed by NASA. I found that asteroids of diameter ˜ 10 m with encounter velocity with the Earth lower than 2.5 km/sec are detected by current surveys nearly 1,000 times more efficiently than the general background of NEAs of that size. Thus the current completion of these slow relative velocity objects may be around 1%, compared to 10^{-6} for that size objects of the general velocity distribution. Current surveys are nowhere near complete, but there may be fewer such objects than have been suggested. This conclusion is reinforced by the fact that at least a couple such discovered objects are known to be not real asteroids but spent rocket bodies in heliocentric orbit, of which there are only of the order of a hundred. Brown et al. (Nature 503, 238-241, 2013, below right, green squares are a re-plot of my blue circles on left plot) recently suggested that the population of small NEAs in the size range from roughly 5 to 50 meters in diameter may have been substantially under-estimated. To be sure, the greatest uncertainty in population estimates is in that range, since there are very few bolide events to use for estimation, and the surveys are extremely incomplete in that size range, so a factor of 3 or so discrepancy is not significant. However, the population estimated from surveys carried still smaller, where the bolide frequency becomes more secure, disagrees from the bolide estimate by even less than a factor of 3 and in fact intersects at about 3 m diameter. On the other hand, the shallow-sloping size-frequency distribution derived from the sparse large bolide data diverges badly from the survey estimates, in sizes where the survey estimates become ever-increasingly reliable, even by 100-200 m diameter. It appears that the bolide data provides a good "anchor" of the population in the size range up to about 5 m diameter, but above that one might do better just connecting that population with a straight line (on a log-log plot) with the survey-determined population at larger size, 50-100 m diameter or so.

  2. Identification of possible genetic alterations in the breast cancer cell line MCF-7 using high-density SNP genotyping microarray

    PubMed Central

    Wang, Hui-Yun; Greenawalt, Danielle; Cui, Xiangfeng; Tereshchenko, Irina V; Luo, Minjie; Yang, Qifeng; Azaro, Marco A; Hu, Guohong; Chu, Yi; Li, James Y; Shen, Li; Lin, Yong; Zhang, Lianjun

    2009-01-01

    Context: Cancer cell lines are used extensively in various research. Knowledge of genetic alterations in these lines is important for understanding mechanisms underlying their biology. However, since paired normal tissues are usually unavailable for comparison, precisely determining genetic alterations in cancer cell lines is difficult. To address this issue, a highly efficient and reliable method is developed. Aims: Establishing a highly efficient and reliable experimental system for genetic profiling of cell lines. Materials and Methods: A widely used breast cancer cell line, MCF-7, was genetically profiled with 4,396 single nucleotide polymorphisms (SNPs) spanning 11 whole chromosomes and two other small regions using a newly developed high-throughput multiplex genotyping approach. Results: The fractions of homozygous SNPs in MCF-7 (13.3%) were significantly lower than those in the control cell line and in 24 normal human individuals (25.1% and 27.4%, respectively). Homozygous SNPs in MCF-7 were found in clusters. The sizes of these clusters were significantly larger than the expected based on random allelic combination. Fourteen such regions were found on chromosomes 1p, 1q, 2q, 6q, 13, 15q, 16q, 17q and 18p in MCF-7 and two in the small regions. Conclusions: These results are generally concordant with those obtained using different approaches but are better in defining their chromosomal positions. The used approach provides a reliable way to detecting possible genetic alterations in cancer cell lines without paired normal tissues. PMID:19439911

  3. Women and Men Together in Recruit Training.

    PubMed

    Orme, Geoffrey J; Kehoe, E James

    2018-05-01

    Although men and women recruits to the Australian Army have trained in mixed-gender platoons since 1995, restrictions on women joining the combat arms were only removed in 2016. As part of a longitudinal study starting with recruit training, this article examined recruit records collected before 2016 with the aims of delineating (1) the relative performance of women versus men in mixed-gender platoons and (2) the relative performance of men in mixed-gender platoons versus all-male platoons. De-identified instructor ratings for 630 females and 4,505 males who completed training between 2011 and 2015 were obtained. Recruits were distributed across 128 platoons (averaging 41.6 members, SD = 8.3) of which 75% contained females, in proportions from 5% to 45%. These analyses were conducted under defense ethics approval DPR-LREP 069-15. Factor analyses revealed that instructor ratings generally loaded onto a single factor, accounting 77.2% of the variance. Consequently, a composite recruit performance score (range 1-5) was computed for 16 of 19 competencies. Analyses of the scores revealed that the distributions of the scores for females and males overlapped considerably. Observed effects were negligible to small in size. The distributions were all centered between 3.0 and 3.5. In mixed-gender platoons, 51% of the females and 52% of the males fell in this band, and 44% of recruits in all-male platoons had scores in this band. The lower three bands (1.0-3.0) contained a slightly greater proportion of females (18%) than males in either mixed-gender platoons (12%) or all-male platoons (12%). Conversely, the upper three bands (3.5-5.0) contained a slightly smaller percentage of females (31%) than males in either mixed-gender platoons (36%) or all-male platoons (44%). Although scores for females were reliably lower than those of males in mixed-gender platoons, χ2 (4) = 16.01, p < 0.01, the effect size (V = 0.07) did not reach the criterion for even a small effect (0.10). For male recruits, those in mixed-gender platoons had scores that were reliably lower than in all-male platoons, χ2 (4) = 48.38, p < 0.001; its effect size (V = 0.11) just exceeded the criterion for a small effect (0.10). Further analyses revealed that male scores had a near-zero correlation (r = -0.033) with the proportion of females in platoons (0-45%). This large-scale secondary analysis of instructor ratings of female and male recruits provides a platform for monitoring the integration of women into the combat arms. The analyses revealed nearly complete overlap in the performance of female versus male recruits. The detected gender-related differences were negligible to small in size. These small differences must be viewed with considerable caution. They may be artifacts of rater bias or other uncontrolled features of the rating system, which was designed for reporting individual recruit performance rather than aggregate analyses. Even with these limitations, this baseline snapshot of recruit performance suggests that, at recruit training, women and men are already working well together, which bodes well for their subsequent integration into the combat arms.

  4. Meta-analysis of attention-deficit/hyperactivity disorder or attention-deficit/hyperactivity disorder symptoms, restriction diet, and synthetic food color additives.

    PubMed

    Nigg, Joel T; Lewis, Kara; Edinger, Tracy; Falk, Michael

    2012-01-01

    The role of diet and of food colors in attention-deficit/hyperactivity disorder (ADHD) or its symptoms warrants updated quantitative meta-analysis, in light of recent divergent policy in Europe and the United States. Studies were identified through a literature search using the PubMed, Cochrane Library, and PsycNET databases through February 2011. Twenty-four publications met inclusion criteria for synthetic food colors; 10 additional studies informed analysis of dietary restriction. A random-effects meta-analytic model generated summary effect sizes. Restriction diets reduced ADHD symptoms at an effect of g = 0.29 (95% CI, 0.07-0.53). For food colors, parent reports yielded an effect size of g = 0.18 (95% CI, 0.08-0.24; p = .0007), which decreased to 0.12 (95% CI, 0.01-0.23; p < .05) after adjustment for possible publication bias. The effect was reliable in studies restricted to food color additives (g = 0.21, 95% CI = 0.06-0.36) but did not survive correction for possible publication bias and was not reliable in studies confined to Food and Drug Administration-approved food colors. Teacher/observer reports yielded a nonsignificant effect of 0.07 (95% CI = -0.03 to 0.18; p = .14). However, high-quality studies confined to color additives yielded a reliable effect (g = 0.22, 95% CI = 0.10-0.41, p = .030) that survived correction. In psychometric tests of attention, the summary effect size was 0.27 (95% CI = 0.07-0.47; p = .007) and survived correction. An estimated 8% of children with ADHD may have symptoms related to synthetic food colors. A restriction diet benefits some children with ADHD. Effects of food colors were notable were but susceptible to publication bias or were derived from small, nongeneralizable samples. Renewed investigation of diet and ADHD is warranted. Copyright © 2012 American Academy of Child and Adolescent Psychiatry. Published by Elsevier Inc. All rights reserved.

  5. Meta-Analysis of Attention-Deficit/Hyperactivity Disorder or Attention-Deficit/Hyperactivity Disorder Symptoms, Restriction Diet, and Synthetic Food Color Additives

    PubMed Central

    Nigg, Joel T.; Lewis, Kara; Edinger, Tracy; Falk, Michael

    2015-01-01

    Objective The role of diet and of food colors in attention-deficit/hyperactivity disorder (ADHD) or its symptoms warrants updated quantitative meta-analysis, in light of recent divergent policy in Europe and the United States. Method Studies were identified through a literature search using the PubMed, Cochrane Library, and PsycNET databases through February 2011. Twenty-four publications met inclusion criteria for synthetic food colors; 10 additional studies informed analysis of dietary restriction. A random-effects meta-analytic model generated summary effect sizes. Results Restriction diets reduced ADHD symptoms at an effect of g = 0.29 (95% CI, 0.07–0.53). For food colors, parent reports yielded an effect size of g = 0.18 (95% CI, 0.08–0.24; p = .0007), which decreased to 0.12 (95% CI, 0.01–0.23; p < .05) after adjustment for possible publication bias. The effect was reliable in studies restricted to food color additives (g = 0.21, 95% CI = 0.06–0.36) but did not survive correction for possible publication bias and was not reliable in studies confined to Food and Drug Administration–approved food colors. Teacher/observer reports yielded a nonsignificant effect of 0.07 (95% CI = −0.03 to 0.18; p = .14). However, high-quality studies confined to color additives yielded a reliable effect (g = 0.22, 95% CI = 0.10–0.41, p = .030) that survived correction. In psychometric tests of attention, the summary effect size was 0.27 (95% CI = 0.07–0.47; p = .007) and survived correction. An estimated 8% of children with ADHD may have symptoms related to synthetic food colors. Conclusions A restriction diet benefits some children with ADHD. Effects of food colors were notable were but susceptible to publication bias or were derived from small, nongeneralizable samples. Renewed investigation of diet and ADHD is warranted. PMID:22176942

  6. How to Compute Electron Ionization Mass Spectra from First Principles.

    PubMed

    Bauer, Christoph Alexander; Grimme, Stefan

    2016-06-02

    The prediction of electron ionization (EI) mass spectra (MS) from first principles has been a major challenge for quantum chemistry (QC). The unimolecular reaction space grows rapidly with increasing molecular size. On the one hand, statistical models like Eyring's quasi-equilibrium theory and Rice-Ramsperger-Kassel-Marcus theory have provided valuable insight, and some predictions and quantitative results can be obtained from such calculations. On the other hand, molecular dynamics-based methods are able to explore automatically the energetically available regions of phase space and thus yield reaction paths in an unbiased way. We describe in this feature article the status of both methodologies in relation to mass spectrometry for small to medium sized molecules. We further present results obtained with the QCEIMS program developed in our laboratory. Our method, which incorporates stochastic and dynamic elements, has been a significant step toward the reliable routine calculation of EI mass spectra.

  7. Characteristics of an under-expanded supersonic flow in arcjet plasmas

    NASA Astrophysics Data System (ADS)

    Namba, Shinichi; Shikama, Taiichi; Sasano, Wataru; Tamura, Naoki; Endo, Takuma

    2018-06-01

    A compact apparatus to produce arcjet plasma was fabricated to investigate supersonic flow dynamics. Periodic bright–dark emission structures were formed in the arcjets, depending on the plasma source and ambient gas pressures in the vacuum chamber. A directional Langmuir probe (DLP) and emission spectroscopy were employed to characterize plasma parameters such as the Mach number of plasma flows and clarify the mechanism for the generation of the emission pattern. In particular, in order to investigate the influence of the Mach number on probe size, we used two DLPs of different probe size. The results indicated that the arcjets could be classified into shock-free expansion and under-expansion, and the behavior of plasma flow could be described by compressible fluid dynamics. Comparison of the Langmuir probe results with emission and laser absorption spectroscopy showed that the small diameter probe was reliable to determine the Mach number, even for the supersonic jet.

  8. Temperature-touch interaction: Weber's phenomenon revisited.

    PubMed

    Stevens, J C; Green, B G

    1978-09-01

    The six experiments reported here stemmed from Weber's (E. H. Weber, In R. Wagner (Ed.), Handwnörterbuch der Physiologie, 1846. Vol. 3, pp. 481-588) report that cold objects on the forehead feel heavier than warm ones, implying an effect of temperature on the touch modality. The experiments arrived at first-order answers to how temperature, force of stimulation, areal size of stimulation, and body locus might influence the magnitude of touch sensation. Typically, concomitant cooling greatly intensifies touch magnitude as perceived via the forehead and the forearm. Warning has little or no effect via the forehead but gives a significant intensification (less pronounced than that of cooling) on the forearm. When the areal size of the stimulation becomes very small, the intensification effects cannot be reliably demonstrated. The findings are reviewed in the light of what is known about the physiology of the cutaneous nerves.

  9. Development of the 3-SET 4P questionnaire for evaluating former ICU patients' physical and psychosocial problems over time: a pilot study.

    PubMed

    Akerman, Eva; Fridlund, Bengt; Ersson, Anders; Granberg-Axéll, Anetth

    2009-04-01

    Current studies reveal a lack of consensus for the evaluation of physical and psychosocial problems after ICU stay and their changes over time. The aim was to develop and evaluate the validity and reliability of a questionnaire for assessing physical and psychosocial problems over time for patients following ICU recovery. Thirty-nine patients completed the questionnaire, 17 were retested. The questionnaire was constructed in three sets: physical problems, psychosocial problems and follow-up care. Face and content validity were tested by nurses, researchers and patients. The questionnaire showed good construct validity in all three sets and had strong factor loadings (explained variance >70%, factor loadings >0.5) for all three sets. There was good concurrent validity compared with the SF 12 (r(s)>0.5). Internal consistency was shown to be reliable (Cronbach's alpha 0.70-0.85). Stability reliability on retesting was good for the physical and psychosocial sets (r(s)>0.5). The 3-set 4P questionnaire was a first step in developing an instrument for assessment of former ICU patients' problems over time. The sample size was small and thus, further studies are needed to confirm these findings.

  10. High resolution optical shaft encoder for motor speed control based on an optical disk pick-up

    NASA Astrophysics Data System (ADS)

    Yeh, Wei-Hung; Bletscher, Warren; Mansuripur, M.

    1998-08-01

    Using a three-beam optical pick-up from a compact disk player and a flexible, shaft-mounted diffraction grating, we obtain information about the rotation speed and angular position of the motor's spindle. This information may be used for feedback to the motor for smooth operation. Due to the small size of the focused spot and the built-in auto-focus mechanism of the optical head, the proposed encoder can achieve submicrometer resolution. With high resolution, reliable operation, and low-cost elements, the proposed method is suitable for rotary and linear motion control where accurate positioning of an object is required.

  11. Say hello to the DSO

    NASA Astrophysics Data System (ADS)

    Pate, G.; Roberts, T.

    1981-05-01

    In the 2-to-10 GHz frequency range, the dielectrically stabilized oscillators (DSOs) with their small size, simple construction, and modest bias requirements, have advantages over cavity-stabilized oscillators (CSOs) and crystal-controlled multiplier chains (XCOs). Commercially available DSOs consist of a transistor oscillator locked to some frequency by a resonant disk of dielectric material. The disk is coupled to a microstrip line at the output of the oscillator. The stability of a DSO lies between that of a crystal-controlled oscillator and that of a cavity-stabilized oscillator. Dielectrically stabilized oscillators, built with nine basic parts and few solder joints, can be expected to be much more reliable than a CSO or XCO.

  12. VizieR Online Data Catalog: SAMI Galaxy Survey: gas streaming (Cecil+, 2016)

    NASA Astrophysics Data System (ADS)

    Cecil, G.; Fogarty, L. M. R.; Richards, S.; Bland-Hawthorn, J.; Lange, R.; Moffett, A.; Catinella, B.; Cortese, L.; Ho, I.-T.; Taylor, E. N.; Bryant, J. J.; Allen, J. T.; Sweet, S. M.; Croom, S. M.; Driver, S. P.; Goodwin, M.; Kelvin, L.; Green, A. W.; Konstantopoulos, I. S.; Owers, M. S.; Lawrence, J. S.; Lorente, N. P. F.

    2016-08-01

    From the first ~830 targets observed in the SGS, we selected 344 rotationally supported galaxies having enough gas to map their CSC. We rejected 8 whose inclination angle to us is too small (i<20°) to be established reliably by photometry, and those very strongly barred or in obvious interactions. Finally, we rejected those whose CSC would be smeared excessively by our PSF (Sect. 2.3.1) because of large inclination (i>71°), compact size, or observed in atrocious conditions, leaving 163 SGS GAMA survey sub-sample and 15 "cluster" sub-sample galaxies with discs. (3 data files).

  13. Superior model for fault tolerance computation in designing nano-sized circuit systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Singh, N. S. S., E-mail: narinderjit@petronas.com.my; Muthuvalu, M. S., E-mail: msmuthuvalu@gmail.com; Asirvadam, V. S., E-mail: vijanth-sagayan@petronas.com.my

    2014-10-24

    As CMOS technology scales nano-metrically, reliability turns out to be a decisive subject in the design methodology of nano-sized circuit systems. As a result, several computational approaches have been developed to compute and evaluate reliability of desired nano-electronic circuits. The process of computing reliability becomes very troublesome and time consuming as the computational complexity build ups with the desired circuit size. Therefore, being able to measure reliability instantly and superiorly is fast becoming necessary in designing modern logic integrated circuits. For this purpose, the paper firstly looks into the development of an automated reliability evaluation tool based on the generalizationmore » of Probabilistic Gate Model (PGM) and Boolean Difference-based Error Calculator (BDEC) models. The Matlab-based tool allows users to significantly speed-up the task of reliability analysis for very large number of nano-electronic circuits. Secondly, by using the developed automated tool, the paper explores into a comparative study involving reliability computation and evaluation by PGM and, BDEC models for different implementations of same functionality circuits. Based on the reliability analysis, BDEC gives exact and transparent reliability measures, but as the complexity of the same functionality circuits with respect to gate error increases, reliability measure by BDEC tends to be lower than the reliability measure by PGM. The lesser reliability measure by BDEC is well explained in this paper using distribution of different signal input patterns overtime for same functionality circuits. Simulation results conclude that the reliability measure by BDEC depends not only on faulty gates but it also depends on circuit topology, probability of input signals being one or zero and also probability of error on signal lines.« less

  14. Does Litter Size Variation Affect Models of Terrestrial Carnivore Extinction Risk and Management?

    PubMed Central

    Devenish-Nelson, Eleanor S.; Stephens, Philip A.; Harris, Stephen; Soulsbury, Carl; Richards, Shane A.

    2013-01-01

    Background Individual variation in both survival and reproduction has the potential to influence extinction risk. Especially for rare or threatened species, reliable population models should adequately incorporate demographic uncertainty. Here, we focus on an important form of demographic stochasticity: variation in litter sizes. We use terrestrial carnivores as an example taxon, as they are frequently threatened or of economic importance. Since data on intraspecific litter size variation are often sparse, it is unclear what probability distribution should be used to describe the pattern of litter size variation for multiparous carnivores. Methodology/Principal Findings We used litter size data on 32 terrestrial carnivore species to test the fit of 12 probability distributions. The influence of these distributions on quasi-extinction probabilities and the probability of successful disease control was then examined for three canid species – the island fox Urocyon littoralis, the red fox Vulpes vulpes, and the African wild dog Lycaon pictus. Best fitting probability distributions differed among the carnivores examined. However, the discretised normal distribution provided the best fit for the majority of species, because variation among litter-sizes was often small. Importantly, however, the outcomes of demographic models were generally robust to the distribution used. Conclusion/Significance These results provide reassurance for those using demographic modelling for the management of less studied carnivores in which litter size variation is estimated using data from species with similar reproductive attributes. PMID:23469140

  15. Does litter size variation affect models of terrestrial carnivore extinction risk and management?

    PubMed

    Devenish-Nelson, Eleanor S; Stephens, Philip A; Harris, Stephen; Soulsbury, Carl; Richards, Shane A

    2013-01-01

    Individual variation in both survival and reproduction has the potential to influence extinction risk. Especially for rare or threatened species, reliable population models should adequately incorporate demographic uncertainty. Here, we focus on an important form of demographic stochasticity: variation in litter sizes. We use terrestrial carnivores as an example taxon, as they are frequently threatened or of economic importance. Since data on intraspecific litter size variation are often sparse, it is unclear what probability distribution should be used to describe the pattern of litter size variation for multiparous carnivores. We used litter size data on 32 terrestrial carnivore species to test the fit of 12 probability distributions. The influence of these distributions on quasi-extinction probabilities and the probability of successful disease control was then examined for three canid species - the island fox Urocyon littoralis, the red fox Vulpes vulpes, and the African wild dog Lycaon pictus. Best fitting probability distributions differed among the carnivores examined. However, the discretised normal distribution provided the best fit for the majority of species, because variation among litter-sizes was often small. Importantly, however, the outcomes of demographic models were generally robust to the distribution used. These results provide reassurance for those using demographic modelling for the management of less studied carnivores in which litter size variation is estimated using data from species with similar reproductive attributes.

  16. Sample Size for Tablet Compression and Capsule Filling Events During Process Validation.

    PubMed

    Charoo, Naseem Ahmad; Durivage, Mark; Rahman, Ziyaur; Ayad, Mohamad Haitham

    2017-12-01

    During solid dosage form manufacturing, the uniformity of dosage units (UDU) is ensured by testing samples at 2 stages, that is, blend stage and tablet compression or capsule/powder filling stage. The aim of this work is to propose a sample size selection approach based on quality risk management principles for process performance qualification (PPQ) and continued process verification (CPV) stages by linking UDU to potential formulation and process risk factors. Bayes success run theorem appeared to be the most appropriate approach among various methods considered in this work for computing sample size for PPQ. The sample sizes for high-risk (reliability level of 99%), medium-risk (reliability level of 95%), and low-risk factors (reliability level of 90%) were estimated to be 299, 59, and 29, respectively. Risk-based assignment of reliability levels was supported by the fact that at low defect rate, the confidence to detect out-of-specification units would decrease which must be supplemented with an increase in sample size to enhance the confidence in estimation. Based on level of knowledge acquired during PPQ and the level of knowledge further required to comprehend process, sample size for CPV was calculated using Bayesian statistics to accomplish reduced sampling design for CPV. Copyright © 2017 American Pharmacists Association®. Published by Elsevier Inc. All rights reserved.

  17. Ocular biometry by computed tomography in different dog breeds.

    PubMed

    Chiwitt, Carolin L H; Baines, Stephen J; Mahoney, Paul; Tanner, Andrew; Heinrich, Christine L; Rhodes, Michael; Featherstone, Heidi J

    2017-09-01

    To (i) correlate B-mode ocular ultrasound (US) and computed tomography (CT) (prospective pilot study), (ii) establish a reliable method to measure the normal canine eye using CT, (iii) establish a reference guide for some dog breeds, (iv) compare eye size between different breeds and breed groups, and (v) investigate the correlation between eye dimensions and body weight, gender, and skull type (retrospective study). B-mode US and CT were performed on ten sheep cadaveric eyes. CT biometry involved 100 adult pure-bred dogs with nonocular and nonorbital disease, representing eleven breeds. Eye length, width, and height were each measured in two of three planes (horizontal, sagittal, and equatorial). B-mode US and CT measurements of sheep cadaveric eyes correlated well (0.70-0.71). The shape of the canine eye was found to be akin to an oblate spheroid (a flattened sphere). A reference guide was established for eleven breeds. Eyes of large breed dogs were significantly larger than those of medium and small breed dogs (P < 0.01), and eyes of medium breed dogs were significantly larger than those of small breed dogs (P < 0.01). Eye size correlated with body weight (0.74-0.82) but not gender or skull type. Computed tomography is a suitable method for biometry of the canine eye, and a reference guide was established for eleven breeds. Eye size correlated with breed size and body weight. Because correlation between B-mode US and CT was shown, the obtained values can be applied in the clinical setting, for example, for the diagnosis of microphthalmos and buphthalmos. © 2016 American College of Veterinary Ophthalmologists.

  18. Finding Mars-Sized Planets in Inner Orbits of Other Stars by Photometry

    NASA Technical Reports Server (NTRS)

    Borucki, W.; Cullers, K.; Dunham, E.; Koch, D.; Mena-Werth, J.; Cuzzi, Jeffrey N. (Technical Monitor)

    1995-01-01

    High precision photometry from a spaceborne telescope has the potential of discovering sub-earth sized inner planets. Model calculations by Wetherill indicate that Mars-sized planets can be expected to form throughout the range of orbits from that of Mercury to Mars. While a transit of an Earth-sized planet causes a 0.084% decrease in brightness from a solar-like star, a transit of a planet as small as Mars causes a flux decrease of only 0.023%. Stellar variability will be the limiting factor for transit measurements. Recent analysis of solar variability from the SOLSTICE experiment shows that much of the variability is in the UV at <400 nm. Combining this result with the total flux variability measured by the ACRIM-1 photometer implies that the Sun has relative amplitude variations of about 0.0007% in the 17-69 pHz bandpass and is presumably typical for solar-like stars. Tests were conducted at Lick Observatory to determine the photometric precision of CCD detectors in the 17-69 pHz bandpass. With frame-by-frame corrections of the image centroids it was found that a precision of 0.001% could be readily achieved, corresponding to a signal to noise ratio of 1.4, provided the telescope aperture was sufficient to keep the statistical noise below 0.0006%. With 24 transits a planet as small as Mars should be reliably detectable. If Wetherill's models are correct in postulating that Mars-like planets are present in Mercury-like orbits, then a six year search should be able to find them.

  19. Development of Thin-Film Battery Powered Transdermal Medical Devices

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bates, J.B.; Sein, T.

    1999-07-06

    Research carried out at ORNL has led to the development of solid state thin-film rechargeable lithium and lithium-ion batteries. These unique devices can be fabricated in a variety of shapes and to any required size, large or small, on virtually any type of substrate. Because they have high energies per unit of volume and mass and because they are rechargeable, thin-film lithium batteries have potentially many applications as small power supplies in consumer and special electronic products. Initially, the objective of this project was to develop thin-film battery powered products. Initially, the objective of this project was to develop thin-filmmore » battery powered transdermal electrodes for recording electrocardiograms and electroencephalograms. These ''active'' electrode would eliminate the effect of interference and improve the reliability in diagnosing heart or brain malfunctions. Work in the second phase of this project was directed at the development of thin-film battery powered implantable defibrillators.« less

  20. Sensitive bistable magnetic sensors using twisted amorphous magnetostrictive ribbons due to Matteucci effect

    NASA Astrophysics Data System (ADS)

    Mohri, K.; Takeuchi, S.

    1982-11-01

    New sensitive magnetic-field sensors are presented using twisted amorphous magnetostrictive ribbons such as Fe80B20 and Fe81-xCrxB17Si2. Sharp voltage pulses are induced between ends of the ribbon of as short as 25 mm or at the terminals of the detecting coil against external fields of as low as 1 Oe and 0.01 Hz-6 kHz. The domain nucleation field at the bistable flux reversal is very constant for 130 °C, 600 h using Fe79Cr2B17Si2, and a possible maximum operating temperature is about 180 °C. Small sized magnetic sensors without any windings for detecting rotational speed, distance, and other mechanical quantities are realized using the twisted ribbons by combining with small magnets. These sensitive and reliable magnetic sensors with digital outputs are suitable for applications in industrial robots and automobiles controlled with microcomputers.

  1. SU-E-T-630: Predictive Modeling of Mortality, Tumor Control, and Normal Tissue Complications After Stereotactic Body Radiotherapy for Stage I Non-Small Cell Lung Cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lindsay, WD; Oncora Medical, LLC, Philadelphia, PA; Berlind, CG

    Purpose: While rates of local control have been well characterized after stereotactic body radiotherapy (SBRT) for stage I non-small cell lung cancer (NSCLC), less data are available characterizing survival and normal tissue toxicities, and no validated models exist assessing these parameters after SBRT. We evaluate the reliability of various machine learning techniques when applied to radiation oncology datasets to create predictive models of mortality, tumor control, and normal tissue complications. Methods: A dataset of 204 consecutive patients with stage I non-small cell lung cancer (NSCLC) treated with stereotactic body radiotherapy (SBRT) at the University of Pennsylvania between 2009 and 2013more » was used to create predictive models of tumor control, normal tissue complications, and mortality in this IRB-approved study. Nearly 200 data fields of detailed patient- and tumor-specific information, radiotherapy dosimetric measurements, and clinical outcomes data were collected. Predictive models were created for local tumor control, 1- and 3-year overall survival, and nodal failure using 60% of the data (leaving the remainder as a test set). After applying feature selection and dimensionality reduction, nonlinear support vector classification was applied to the resulting features. Models were evaluated for accuracy and area under ROC curve on the 81-patient test set. Results: Models for common events in the dataset (such as mortality at one year) had the highest predictive power (AUC = .67, p < 0.05). For rare occurrences such as radiation pneumonitis and local failure (each occurring in less than 10% of patients), too few events were present to create reliable models. Conclusion: Although this study demonstrates the validity of predictive analytics using information extracted from patient medical records and can most reliably predict for survival after SBRT, larger sample sizes are needed to develop predictive models for normal tissue toxicities and more advanced machine learning methodologies need be consider in the future.« less

  2. Investigating Reliabilities of Intraindividual Variability Indicators

    ERIC Educational Resources Information Center

    Wang, Lijuan; Grimm, Kevin J.

    2012-01-01

    Reliabilities of the two most widely used intraindividual variability indicators, "ISD[superscript 2]" and "ISD", are derived analytically. Both are functions of the sizes of the first and second moments of true intraindividual variability, the size of the measurement error variance, and the number of assessments within a burst. For comparison,…

  3. Fluorescent tag is not a reliable marker for small RNA transfection in the presence of serum.

    PubMed

    Han, Jing; Wang, Qi-Wei; Wang, Shi-Qiang

    2013-09-01

    Chemically synthetic siRNA and miRNA have become powerful tools to study gene function in the past decade. Fluorescent dyes covalently attached to the 5' or 3' ends of synthetic small RNAs are widely used for fluorescently imaging and detection of these RNAs. However, the reliability of fluorescent tags as small RNA markers in different conditions has not attracted enough attention. We used Cy3-labelled small RNAs to explore the reliability of fluorescent tags as small RNA markers in cell cultures involving serum. A strong Cy3-fluorescence signal was observed in the cytoplasm of the cells transfected with Cy3-miR24 in the culture medium containing fetal bovine serum (FBS), but qRT-PCR results showed that little miR24 were detected in these cells. Further study demonstrated that small RNAs were degraded in the presence of FBS, suggesting that it was Cy3-RNA fragments, rather than the original Cy3-miR24, diffused into cells. These phenomena disappeared when FBS was replaced by boiled-FBS, further supporting that the Cy3-fluorescence we observed in cells in the presence of FBS could not represent the presence of intact small RNAs. These findings addressed that fluorescent tags are not reliable for small RNA transfection in the presence of serum in culture.

  4. Determination of the folate content in cladodes of nopal (Opuntia ficus indica) by microbiological assay utilizing Lactobacillus casei (ATCC 7469) and enzyme-linked immunosorbent assay.

    PubMed

    Ortiz-Escobar, Tania Breshkovskaya; Valverde-González, Maria Elena; Paredes-López, Octavio

    2010-05-26

    Prickly pear cactus has been an important food source in Mexico since ancient times due to its economical and ecological benefits and potential nutraceutical value. Nevertheless, studies on the nutritional aspects and health benefits have been scarce. The purpose of this study was to assess, apparently for the first time, the folate contents of cladodes of nopal by a microbiological assay, using Lactobacillus casei (ATCC 7469) in extracts that were enzymatically treated to release the bound vitamin, employing single, dual, and trienzymatic procedures, and using the enzyme-linked immunosorbent assay (ELISA). We used Opuntia cladodes of different length sizes. The microbiological assay showed some differences among enzyme treatments and sizes of nopal; the trienzyme treatment (alpha-amylase-protease-conjugase) was more efficient in determining the folate content in nopal, giving 5.0 ng/g in the small size cladodes at 54 h of testing time, while ELISA showed no significant differences in the folate content among sizes of cladodes (5.5-5.62 ng/g at 0 min testing time). Both techniques may be used for the assessment of folate content in cladodes, but ELISA is more rapid and reliable.

  5. A mass-density model can account for the size-weight illusion

    PubMed Central

    Bergmann Tiest, Wouter M.; Drewing, Knut

    2018-01-01

    When judging the heaviness of two objects with equal mass, people perceive the smaller and denser of the two as being heavier. Despite the large number of theories, covering bottom-up and top-down approaches, none of them can fully account for all aspects of this size-weight illusion and thus for human heaviness perception. Here we propose a new maximum-likelihood estimation model which describes the illusion as the weighted average of two heaviness estimates with correlated noise: One estimate derived from the object’s mass, and the other from the object’s density, with estimates’ weights based on their relative reliabilities. While information about mass can directly be perceived, information about density will in some cases first have to be derived from mass and volume. However, according to our model at the crucial perceptual level, heaviness judgments will be biased by the objects’ density, not by its size. In two magnitude estimation experiments, we tested model predictions for the visual and the haptic size-weight illusion. Participants lifted objects which varied in mass and density. We additionally varied the reliability of the density estimate by varying the quality of either visual (Experiment 1) or haptic (Experiment 2) volume information. As predicted, with increasing quality of volume information, heaviness judgments were increasingly biased towards the object’s density: Objects of the same density were perceived as more similar and big objects were perceived as increasingly lighter than small (denser) objects of the same mass. This perceived difference increased with an increasing difference in density. In an additional two-alternative forced choice heaviness experiment, we replicated that the illusion strength increased with the quality of volume information (Experiment 3). Overall, the results highly corroborate our model, which seems promising as a starting point for a unifying framework for the size-weight illusion and human heaviness perception. PMID:29447183

  6. A mass-density model can account for the size-weight illusion.

    PubMed

    Wolf, Christian; Bergmann Tiest, Wouter M; Drewing, Knut

    2018-01-01

    When judging the heaviness of two objects with equal mass, people perceive the smaller and denser of the two as being heavier. Despite the large number of theories, covering bottom-up and top-down approaches, none of them can fully account for all aspects of this size-weight illusion and thus for human heaviness perception. Here we propose a new maximum-likelihood estimation model which describes the illusion as the weighted average of two heaviness estimates with correlated noise: One estimate derived from the object's mass, and the other from the object's density, with estimates' weights based on their relative reliabilities. While information about mass can directly be perceived, information about density will in some cases first have to be derived from mass and volume. However, according to our model at the crucial perceptual level, heaviness judgments will be biased by the objects' density, not by its size. In two magnitude estimation experiments, we tested model predictions for the visual and the haptic size-weight illusion. Participants lifted objects which varied in mass and density. We additionally varied the reliability of the density estimate by varying the quality of either visual (Experiment 1) or haptic (Experiment 2) volume information. As predicted, with increasing quality of volume information, heaviness judgments were increasingly biased towards the object's density: Objects of the same density were perceived as more similar and big objects were perceived as increasingly lighter than small (denser) objects of the same mass. This perceived difference increased with an increasing difference in density. In an additional two-alternative forced choice heaviness experiment, we replicated that the illusion strength increased with the quality of volume information (Experiment 3). Overall, the results highly corroborate our model, which seems promising as a starting point for a unifying framework for the size-weight illusion and human heaviness perception.

  7. Validity, reliability and responsiveness of the EQ-5D in German stroke patients undergoing rehabilitation.

    PubMed

    Hunger, Matthias; Sabariego, Carla; Stollenwerk, Björn; Cieza, Alarcos; Leidl, Reiner

    2012-09-01

    To analyse the psychometric properties of the EQ-5D in German stroke survivors undergoing neurological rehabilitation. The EQ-5D, the Hospital Anxiety and Depression Scale (HADS) and the Stroke Impact Scale (SIS) were completed before (210 subjects) and after (183 subjects) a patient education programme in seven rehabilitation clinics in Bavaria, Germany. A postal follow-up was conducted after 6 months. Acceptance, validity, reliability and responsiveness of the EQ-5D were tested. The SIS subscales were used as external anchors to classify the patients into change groups between the measurements. The proportion of missing answers ranged from 4.7 to 8.6%. Between 16 and 19% reported no problems in any EQ-5D dimension. At baseline, correlations between EQ-5D index and the SIS subscales ranged from 0.15 (communication) to 0.60 (mobility). Correlations with the EQ VAS were slightly smaller. All scores were reliable in test-retest with intraclass correlations ranging from 0.67 to 0.81. EQ-5D index and EQ VAS were consistently responsive only to improvements in health, showing small- to medium effect sizes (0.27-0.42). The EQ-5D has shown reasonable validity, reliability and, more limited, responsiveness in stroke patients with mild to moderate limitations of functional status, allowing it to be used in clinical trials in rehabilitation.

  8. A hard-to-read font reduces the framing effect in a large sample.

    PubMed

    Korn, Christoph W; Ries, Juliane; Schalk, Lennart; Oganian, Yulia; Saalbach, Henrik

    2018-04-01

    How can apparent decision biases, such as the framing effect, be reduced? Intriguing findings within recent years indicate that foreign language settings reduce framing effects, which has been explained in terms of deeper cognitive processing. Because hard-to-read fonts have been argued to trigger deeper cognitive processing, so-called cognitive disfluency, we tested whether hard-to-read fonts reduce framing effects. We found no reliable evidence for an effect of hard-to-read fonts on four framing scenarios in a laboratory (final N = 158) and an online study (N = 271). However, in a preregistered online study with a rather large sample (N = 732), a hard-to-read font reduced the framing effect in the classic "Asian disease" scenario (in a one-sided test). This suggests that hard-read-fonts can modulate decision biases-albeit with rather small effect sizes. Overall, our findings stress the importance of large samples for the reliability and replicability of modulations of decision biases.

  9. Use of Landsat data to predict the trophic state of Minnesota lakes

    NASA Technical Reports Server (NTRS)

    Lillesand, T. M.; Johnson, W. L.; Deuell, R. L.; Lindstrom, O. M.; Meisner, D. E.

    1983-01-01

    Near-concurrent Landsat Multispectral Scanner (MSS) and ground data were obtained for 60 lakes distributed in two Landsat scene areas. The ground data included measurement of secchi disk depth, chlorophyll-a, total phosphorous, turbidity, color, and total nitrogen, as well as Carlson Trophic State Index (TSI) values derived from the first three parameters. The Landsat data best correlated with the TSI values. Prediction models were developed to classify some 100 'test' lakes appearing in the two analysis scenes on the basis of TSI estimates. Clouds, wind, poor image data, small lake size, and shallow lake depth caused some problems in lake TSI prediction. Overall, however, the Landsat-predicted TSI estimates were judged to be very reliable for the secchi-derived TSI estimation, moderately reliable for prediction of the chlorophyll-a TSI, and unreliable for the phosphorous value. Numerous Landsat data extraction procedures were compared, and the success of the Landsat TSI prediction models was a strong function of the procedure employed.

  10. Characterization of microplastic litter from oceans by an innovative approach based on hyperspectral imaging.

    PubMed

    Serranti, Silvia; Palmieri, Roberta; Bonifazi, Giuseppe; Cózar, Andrés

    2018-06-01

    An innovative approach, based on HyperSpectral Imaging (HSI), was developed in order to set up an efficient method to analyze marine microplastic litter. HSI was applied to samples collected by surface-trawling plankton nets from several parts of the world (i.e. Arctic, Mediterranean, South Atlantic and North Pacific). Reliable information on abundance, size, shape and polymer type for the whole ensemble of plastic particles in each sample was retrieved from single hyperspectral images. The simultaneous characterization of the polymeric composition of the plastic debris represents an important analytical advantage considering that this information, and even the validation of the plastic nature of the small debris, is a common flaw in the analysis of marine microplastic pollution. HSI was revealed as a rapid, non-invasive, non-destructive and reliable technology for the characterization of the microplastic waste, opening a promising way for improving the plastic pollution monitoring. Copyright © 2018 Elsevier Ltd. All rights reserved.

  11. Performance Enhancement of a High Speed Jet Impingement System for Nonvolatile Residue Removal

    NASA Technical Reports Server (NTRS)

    Klausner, James F.; Mei, Renwei; Near, Steve; Stith, Rex

    1996-01-01

    A high speed jet impingement cleaning facility has been developed to study the effectiveness of the nonvolatile residue removal. The facility includes a high pressure air compressor which charges the k-bottles to supply high pressure air, an air heating section to vary the temperature of the high pressure air, an air-water mixing chamber to meter the water flow and generate small size droplets, and a converging- diverging nozzle to deliver the supersonic air-droplet mixture flow to the cleaning surface. To reliably quantify the cleanliness of the surface, a simple procedure for measurement and calibration is developed to relate the amount of the residue on the surface to the relative change in the reflectivity between a clean surface and the greased surface. This calibration procedure is economical, simple, reliable, and robust. a theoretical framework is developed to provide qualitative guidance for the design of the test and interpretation of the experimental results. The result documented in this report support the theoretical considerations.

  12. Effects of Age and Size on Xylem Phenology in Two Conifers of Northwestern China.

    PubMed

    Zeng, Qiao; Rossi, Sergio; Yang, Bao

    2017-01-01

    The climatic signals that directly affect the trees can be registered by xylem during its growth. If the timings and duration of xylem formation change, xylogenesis can occur under different environmental conditions and subsequently be subject to different climatic signals. An experimental design was applied in the field to disentangle the effects of age and size on xylem phenology, and it challenges the hypothesis that the timings and dynamics of xylem growth are size-dependent. Intra-annual dynamics of xylem formation were monitored weekly during the growing seasons 2013 and 2014 in Chinese pine ( Pinus tabulaeformis ) and Qilian juniper ( Juniperus przewalskii ) with different sizes and ages in a semi-arid region of northwestern China. Cell differentiation started 3 weeks earlier in 2013 and terminated 1 week later in 2014 in small-young pines than in big-old pines. However, differences in the timings of growth reactivation disappeared when comparing the junipers with different sizes but similar age. Overall, 77 days were required for xylem differentiation to take place, but timings were shorter for older trees, which also exhibited smaller cell production. Results from this study suggest that tree age does play an important role in timings and duration of growth. The effect of age should also be considered to perform reliable responses of trees to climate.

  13. The effect of data points per x- to y-axis ratio on visual analysts evaluation of single-case graphs.

    PubMed

    Radley, Keith C; Dart, Evan H; Wright, Sarah J

    2018-02-15

    Research based on single-case designs (SCD) are frequently utilized in educational settings to evaluate the effect of an intervention on student behavior. Visual analysis is the primary method of evaluation of SCD, despite research noting concerns regarding reliability of the procedure. Recent research suggests that characteristics of the graphic display may contribute to poor reliability and overestimation of intervention effects. This study investigated the effect of increasing or decreasing the data points per x- to y-axis ratio (DPPXYR) on rater evaluations of functional relation and effect size in SCD data sets. Twenty-nine individuals (58.6% male) with experience in SCD were asked to evaluate 40 multiple baseline data sets. Two data sets reporting null, small, moderate, and large intervention effects (8 total) were modified by manipulating the ratio of the x- to y-axis (5 variations), resulting in 40 total graphs. Results indicate that raters scored effects as larger as the DPPXYR decreased. Additionally, a 2-way within-subjects analysis of variance (ANOVA) revealed a significant main effect of DPPXYR manipulation on effect size rating, F(2.11, 58.98) = 58.05, p < .001, η2 = .675, and an interaction between DPPXYR manipulation and magnitude of effect, F(6.71, 187.78) = 11.45, p < .001, η2 = .29. Overall, results of the study indicate researchers and practitioners should maintain a DPPXYR of .14 or larger in the interest of more conservative effect size judgments. (PsycINFO Database Record (c) 2018 APA, all rights reserved).

  14. Reliability Through Life of Internal Protection Devices in Small-Cell ABSL Batteries

    NASA Technical Reports Server (NTRS)

    Neubauer, Jeremy; Ng, Ka Lok; Bennetti, Andrea; Pearson, Chris; Rao, gopal

    2007-01-01

    This viewgraph presentation reviews a reliability analysis of small cell protection batteries. The contents include: 1) The s-p Topology; 2) Cell Level Protection Devices; 3) Battery Level Fault Protection; 4) Large Cell Comparison; and 5) Battery Level Testing and Results.

  15. Prospects for small cryocoolers. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Radebaugh, R.

    1982-01-01

    Small cryocoolers are commonly used in the areas of infrared detection, satellite communication, and cryopumps. Some emerging application areas deal with SQUID and Josephson junction devices, which require temperatures of about 8 K or below. The need for high reliability in these small cryocoolers has dictated the use of regenerative-cycle machines, but such machines are presently limited to temperatures above about 8 K. This paper discusses some of the research being done to improve reliability, decrease noise, and reduce the low-temperature limit of small cryocoolers.

  16. Measuring Submicron-Sized Fractionated Particulate Matter on Aluminum Impactor Disks

    PubMed Central

    Buchholz, Bruce A.; Zermeño, Paula; Hwang, Hyun-Min; Young, Thomas M.; Guilderson, Thomas P.

    2011-01-01

    Sub-micron sized airborne particulate matter (PM) is not collected well on regular quartz or glass fiber filter papers. We used a micro-orifice uniform deposit impactor (MOUDI) to fractionate PM into six size fractions and deposit it on specially designed high purity thin aluminum disks. The MOUDI separated PM into fractions 56–100 nm, 100–180 nm, 180–320 nm, 320–560 nm, 560–1000 nm, and 1000–1800 nm. Since the MOUDI has a low flow rate (30 L/min), it takes several days to collect sufficient carbon on 47 mm foil disks. The small carbon mass (20–200 microgram C) and large aluminum substrate (~25 mg Al) present several challenges to production of graphite targets for accelerator mass spectrometry (AMS) analysis. The Al foil consumes large amounts of oxygen as it is heated and tends to melt into quartz combustion tubes, causing gas leaks. We describe sample processing techniques to reliably produce graphitic targets for 14C-AMS analysis of PM deposited on Al impact foils. PMID:22228915

  17. Model selection with multiple regression on distance matrices leads to incorrect inferences.

    PubMed

    Franckowiak, Ryan P; Panasci, Michael; Jarvis, Karl J; Acuña-Rodriguez, Ian S; Landguth, Erin L; Fortin, Marie-Josée; Wagner, Helene H

    2017-01-01

    In landscape genetics, model selection procedures based on Information Theoretic and Bayesian principles have been used with multiple regression on distance matrices (MRM) to test the relationship between multiple vectors of pairwise genetic, geographic, and environmental distance. Using Monte Carlo simulations, we examined the ability of model selection criteria based on Akaike's information criterion (AIC), its small-sample correction (AICc), and the Bayesian information criterion (BIC) to reliably rank candidate models when applied with MRM while varying the sample size. The results showed a serious problem: all three criteria exhibit a systematic bias toward selecting unnecessarily complex models containing spurious random variables and erroneously suggest a high level of support for the incorrectly ranked best model. These problems effectively increased with increasing sample size. The failure of AIC, AICc, and BIC was likely driven by the inflated sample size and different sum-of-squares partitioned by MRM, and the resulting effect on delta values. Based on these findings, we strongly discourage the continued application of AIC, AICc, and BIC for model selection with MRM.

  18. On the Scaling of Small, Heat Simulated Jet Noise Measurements to Moderate Size Exhaust Jets

    NASA Technical Reports Server (NTRS)

    McLaughlin, Dennis K.; Bridges, James; Kuo, Ching-Wen

    2010-01-01

    Modern military aircraft jet engines are designed with variable geometry nozzles to provide optimum thrust in different operating conditions, depending on the flight envelope. However, the acoustic measurements for such nozzles are scarce, due to the cost involved in making full scale measurements and the lack of details about the exact geometry of these nozzles. Thus the present effort at The Pennsylvania State University and the NASA Glenn Research Center- in partnership with GE Aviation is aiming to study and characterize the acoustic field produced by supersonic jets issuing from converging-diverging military style nozzles. An equally important objective is to validate methodology for using data obtained from small and moderate scale experiments to reliably predict the most important components of full scale engine noise. The experimental results presented show reasonable agreement between small scale and moderate scale jet acoustic data, as well as between heated jets and heat-simulated ones. Unresolved issues however are identified that are currently receiving our attention, in particular the effect of the small bypass ratio airflow. Future activities will identify and test promising noise reduction techniques in an effort to predict how well such concepts will work with full scale engines in flight conditions.

  19. Reliability and Validity of the Sport Concussion Assessment Tool-3 (SCAT3) in High School and Collegiate Athletes.

    PubMed

    Chin, Esther Y; Nelson, Lindsay D; Barr, William B; McCrory, Paul; McCrea, Michael A

    2016-09-01

    The Sport Concussion Assessment Tool-3 (SCAT3) facilitates sideline clinical assessments of concussed athletes. Yet, there is little published research on clinically relevant metrics for the SCAT3 as a whole. We documented the psychometric properties of the major SCAT3 components (symptoms, cognition, balance) and derived clinical decision criteria (ie, reliable change score cutoffs and normative conversation tables) for clinicians to apply to cases with and without available preinjury baseline data. Cohort study (diagnosis); Level of evidence, 2. High school and collegiate athletes (N = 2018) completed preseason baseline evaluations including the SCAT3. Re-evaluations of 166 injured athletes and 164 noninjured controls were performed within 24 hours of injury and at 8, 15, and 45 days after injury. Analyses focused on predictors of baseline performance, test-retest reliability, and sensitivity and specificity of the SCAT3 using either single postinjury cutoffs or reliable change index (RCI) criteria derived from this sample. Athlete sex, level of competition, attention-deficit/hyperactivity disorder (ADHD), learning disability (LD), and estimated verbal intellectual ability (but not concussion history) were associated with baseline scores on ≥1 SCAT3 components (small to moderate effect sizes). Female sex, high school level of competition (vs college), and ADHD were associated with higher baseline symptom ratings (d = 0.25-0.32). Male sex, ADHD, and LD were associated with lower baseline Standardized Assessment of Concussion (SAC) scores (d = 0.28-0.68). Male sex, high school level of competition, ADHD, and LD were associated with poorer baseline Balance Error Scoring System (BESS) performance (d = 0.14-0.26). After injury, the symptom checklist manifested the largest effect size at the 24-hour assessment (d = 1.52), with group differences diminished but statistically significant at day 8 (d = 0.39) and nonsignificant at day 15. Effect sizes for the SAC and BESS were small to moderate at 24 hours (SAC: d = -0.36; modified BESS: d = 0.46; full BESS: d = 0.51) and became nonsignificant at day 8 (SAC) and day 15 (BESS). Receiver operating characteristic curve analyses demonstrated a stronger discrimination for symptoms (area under the curve [AUC] = 0.86) than cognitive and balance measures (AUCs = 0.58 and 0.62, respectively), with comparable discrimination of each SCAT3 component using postinjury scores alone versus baseline-adjusted scores (P = .71-.90). Normative conversion tables and RCI criteria were created to facilitate the use of the SCAT3 both with and without baseline test results. Individual predictors should be taken into account when interpreting the SCAT3. The normative conversion tables and RCIs presented can be used to help interpret concussed athletes' performance both with and without baseline data, given the comparability of the 2 interpretative approaches. © 2016 The Author(s).

  20. Intra- and Trans-Generational Costs of Reduced Female Body Size Caused by Food Limitation Early in Life in Mites

    PubMed Central

    Walzer, Andreas; Schausberger, Peter

    2013-01-01

    Background Food limitation early in life may be compensated for by developmental plasticity resulting in accelerated development enhancing survival at the expense of small adult body size. However and especially for females in non-matching maternal and offspring environments, being smaller than the standard may incur considerable intra- and trans-generational costs. Methodology/Principal Findings Here, we evaluated the costs of small female body size induced by food limitation early in life in the sexually size-dimorphic predatory mite Phytoseiulus persimilis. Females are larger than males. These predators are adapted to exploit ephemeral spider mite prey patches. The intra- and trans-generational effects of small maternal body size manifested in lower maternal survival probabilities, decreased attractiveness for males, and a reduced number and size of eggs compared to standard-sized females. The trans-generational effects of small maternal body size were sex-specific with small mothers producing small daughters but standard-sized sons. Conclusions/Significance Small female body size apparently intensified the well-known costs of sexual activity because mortality of small but not standard-sized females mainly occurred shortly after mating. The disadvantages of small females in mating and egg production may be generally explained by size-associated morphological and physiological constraints. Additionally, size-assortative mate preferences of standard-sized mates may have rendered small females disproportionally unattractive mating partners. We argue that the sex-specific trans-generational effects were due to sexual size dimorphism – females are the larger sex and thus more strongly affected by maternal stress than the smaller males – and to sexually selected lower plasticity of male body size. PMID:24265745

  1. 13 CFR 121.405 - May a business concern self-certify its small business size status?

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 13 Business Credit and Assistance 1 2010-01-01 2010-01-01 false May a business concern self-certify its small business size status? 121.405 Section 121.405 Business Credit and Assistance SMALL BUSINESS ADMINISTRATION SMALL BUSINESS SIZE REGULATIONS Size Eligibility Provisions and Standards Size...

  2. Acute Respiratory Distress Syndrome Measurement Error. Potential Effect on Clinical Study Results

    PubMed Central

    Cooke, Colin R.; Iwashyna, Theodore J.; Hofer, Timothy P.

    2016-01-01

    Rationale: Identifying patients with acute respiratory distress syndrome (ARDS) is a recognized challenge. Experts often have only moderate agreement when applying the clinical definition of ARDS to patients. However, no study has fully examined the implications of low reliability measurement of ARDS on clinical studies. Objectives: To investigate how the degree of variability in ARDS measurement commonly reported in clinical studies affects study power, the accuracy of treatment effect estimates, and the measured strength of risk factor associations. Methods: We examined the effect of ARDS measurement error in randomized clinical trials (RCTs) of ARDS-specific treatments and cohort studies using simulations. We varied the reliability of ARDS diagnosis, quantified as the interobserver reliability (κ-statistic) between two reviewers. In RCT simulations, patients identified as having ARDS were enrolled, and when measurement error was present, patients without ARDS could be enrolled. In cohort studies, risk factors as potential predictors were analyzed using reviewer-identified ARDS as the outcome variable. Measurements and Main Results: Lower reliability measurement of ARDS during patient enrollment in RCTs seriously degraded study power. Holding effect size constant, the sample size necessary to attain adequate statistical power increased by more than 50% as reliability declined, although the result was sensitive to ARDS prevalence. In a 1,400-patient clinical trial, the sample size necessary to maintain similar statistical power increased to over 1,900 when reliability declined from perfect to substantial (κ = 0.72). Lower reliability measurement diminished the apparent effectiveness of an ARDS-specific treatment from a 15.2% (95% confidence interval, 9.4–20.9%) absolute risk reduction in mortality to 10.9% (95% confidence interval, 4.7–16.2%) when reliability declined to moderate (κ = 0.51). In cohort studies, the effect on risk factor associations was similar. Conclusions: ARDS measurement error can seriously degrade statistical power and effect size estimates of clinical studies. The reliability of ARDS measurement warrants careful attention in future ARDS clinical studies. PMID:27159648

  3. 13 CFR 121.1009 - What are the procedures for making the size determination?

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... the size determination? 121.1009 Section 121.1009 Business Credit and Assistance SMALL BUSINESS ADMINISTRATION SMALL BUSINESS SIZE REGULATIONS Size Eligibility Provisions and Standards Procedures for Size.... The concern whose size is under consideration has the burden of establishing its small business size...

  4. 13 CFR 121.1009 - What are the procedures for making the size determination?

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... the size determination? 121.1009 Section 121.1009 Business Credit and Assistance SMALL BUSINESS ADMINISTRATION SMALL BUSINESS SIZE REGULATIONS Size Eligibility Provisions and Standards Procedures for Size.... The concern whose size is under consideration has the burden of establishing its small business size...

  5. 13 CFR 121.1009 - What are the procedures for making the size determination?

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... the size determination? 121.1009 Section 121.1009 Business Credit and Assistance SMALL BUSINESS ADMINISTRATION SMALL BUSINESS SIZE REGULATIONS Size Eligibility Provisions and Standards Procedures for Size.... The concern whose size is under consideration has the burden of establishing its small business size...

  6. Evaluation of residual uranium contamination in the dirt floor of an abandoned metal rolling mill.

    PubMed

    Glassford, Eric; Spitz, Henry; Lobaugh, Megan; Spitler, Grant; Succop, Paul; Rice, Carol

    2013-02-01

    A single, large, bulk sample of uranium-contaminated material from the dirt floor of an abandoned metal rolling mill was separated into different types and sizes of aliquots to simulate samples that would be collected during site remediation. The facility rolled approximately 11,000 tons of hot-forged ingots of uranium metal approximately 60 y ago, and it has not been used since that time. Thirty small mass (≈ 0.7 g) and 15 large mass (≈ 70 g) samples were prepared from the heterogeneously contaminated bulk material to determine how measurements of the uranium contamination vary with sample size. Aliquots of bulk material were also resuspended in an exposure chamber to produce six samples of respirable particles that were obtained using a cascade impactor. Samples of removable surface contamination were collected by wiping 100 cm of the interior surfaces of the exposure chamber with 47-mm-diameter fiber filters. Uranium contamination in each of the samples was measured directly using high-resolution gamma ray spectrometry. As expected, results for isotopic uranium (i.e., U and U) measured with the large-mass and small-mass samples are significantly different (p < 0.001), and the coefficient of variation (COV) for the small-mass samples was greater than for the large-mass samples. The uranium isotopic concentrations measured in the air and on the wipe samples were not significantly different and were also not significantly different (p > 0.05) from results for the large- or small-mass samples. Large-mass samples are more reliable for characterizing heterogeneously distributed radiological contamination than small-mass samples since they exhibit the least variation compared to the mean. Thus, samples should be sufficiently large in mass to insure that the results are truly representative of the heterogeneously distributed uranium contamination present at the facility. Monitoring exposure of workers and the public as a result of uranium contamination resuspended during site remediation should be evaluated using samples of sufficient size and type to accommodate the heterogeneous distribution of uranium in the bulk material.

  7. Reliability and minimal detectable change of physical performance measures in individuals with pre-manifest and manifest Huntington disease.

    PubMed

    Quinn, Lori; Khalil, Hanan; Dawes, Helen; Fritz, Nora E; Kegelmeyer, Deb; Kloos, Anne D; Gillard, Jonathan W; Busse, Monica

    2013-07-01

    Clinical intervention trials in people with Huntington disease (HD) have been limited by a lack of reliable and appropriate outcome measures. The purpose of this study was to determine the reliability and minimal detectable change (MDC) of various outcome measures that are potentially suitable for evaluating physical functioning in individuals with HD. This was a multicenter, prospective, observational study. Participants with pre-manifest and manifest HD (early, middle, and late stages) were recruited from 8 international sites to complete a battery of physical performance and functional measures at 2 assessments, separated by 1 week. Test-retest reliability (using intraclass correlation coefficients) and MDC values were calculated for all measures. Seventy-five individuals with HD (mean age=52.12 years, SD=11.82) participated in the study. Test-retest reliability was very high (>.90) for participants with manifest HD for the Six-Minute Walk Test (6MWT), 10-Meter Walk Test, Timed "Up & Go" Test (TUG), Berg Balance Scale (BBS), Physical Performance Test (PPT), Barthel Index, Rivermead Mobility Index, and Tinetti Mobility Test (TMT). Many MDC values suggested a relatively high degree of inherent variability, particularly in the middle stage of HD. Minimum detectable change values for participants with manifest HD that were relatively low across disease stages were found for the BBS (5), PPT (5), and TUG (2.98). For individuals with pre-manifest HD (n=11), the 6MWT and Four Square Step Test had high reliability and low MDC values. The sample size for the pre-manifest HD group was small. The BBS, PPT, and TUG appear most appropriate for clinical trials aimed at improving physical functioning in people with manifest HD. Further research in people with pre-manifest HD is necessary.

  8. Visual-haptic integration with pliers and tongs: signal “weights” take account of changes in haptic sensitivity caused by different tools

    PubMed Central

    Takahashi, Chie; Watt, Simon J.

    2014-01-01

    When we hold an object while looking at it, estimates from visual and haptic cues to size are combined in a statistically optimal fashion, whereby the “weight” given to each signal reflects their relative reliabilities. This allows object properties to be estimated more precisely than would otherwise be possible. Tools such as pliers and tongs systematically perturb the mapping between object size and the hand opening. This could complicate visual-haptic integration because it may alter the reliability of the haptic signal, thereby disrupting the determination of appropriate signal weights. To investigate this we first measured the reliability of haptic size estimates made with virtual pliers-like tools (created using a stereoscopic display and force-feedback robots) with different “gains” between hand opening and object size. Haptic reliability in tool use was straightforwardly determined by a combination of sensitivity to changes in hand opening and the effects of tool geometry. The precise pattern of sensitivity to hand opening, which violated Weber's law, meant that haptic reliability changed with tool gain. We then examined whether the visuo-motor system accounts for these reliability changes. We measured the weight given to visual and haptic stimuli when both were available, again with different tool gains, by measuring the perceived size of stimuli in which visual and haptic sizes were varied independently. The weight given to each sensory cue changed with tool gain in a manner that closely resembled the predictions of optimal sensory integration. The results are consistent with the idea that different tool geometries are modeled by the brain, allowing it to calculate not only the distal properties of objects felt with tools, but also the certainty with which those properties are known. These findings highlight the flexibility of human sensory integration and tool-use, and potentially provide an approach for optimizing the design of visual-haptic devices. PMID:24592245

  9. Small Microprocessor for ASIC or FPGA Implementation

    NASA Technical Reports Server (NTRS)

    Kleyner, Igor; Katz, Richard; Blair-Smith, Hugh

    2011-01-01

    A small microprocessor, suitable for use in applications in which high reliability is required, was designed to be implemented in either an application-specific integrated circuit (ASIC) or a field-programmable gate array (FPGA). The design is based on commercial microprocessor architecture, making it possible to use available software development tools and thereby to implement the microprocessor at relatively low cost. The design features enhancements, including trapping during execution of illegal instructions. The internal structure of the design yields relatively high performance, with a significant decrease, relative to other microprocessors that perform the same functions, in the number of microcycles needed to execute macroinstructions. The problem meant to be solved in designing this microprocessor was to provide a modest level of computational capability in a general-purpose processor while adding as little as possible to the power demand, size, and weight of a system into which the microprocessor would be incorporated. As designed, this microprocessor consumes very little power and occupies only a small portion of a typical modern ASIC or FPGA. The microprocessor operates at a rate of about 4 million instructions per second with clock frequency of 20 MHz.

  10. Miniature star tracker for small remote sensing satellites

    NASA Astrophysics Data System (ADS)

    Cassidy, Lawrence W.; Schlom, Leslie

    1995-01-01

    Designers of future remote sensing spacecraft, including platforms for Mission to Planet Earth and small satellites, will be driven to provide spacecraft designs that maximize data return and minimize hardware and operating costs. The attitude determination subsystems of these spacecraft must likewise provide maximum capability and versatility at an affordable price. Hughes Danbury Optical Systems (HDOS) has developed the Model HD-1003 Miniature Star Tracker which combines high accuracy, high reliability and growth margin for `all-stellar' capability in a compact, radiation tolerant design that meets these future spacecraft needs and whose cost is competitive with horizon sensors and digital fine sum sensors. Begun in 1991, our HD-1003 development program has now entered the hardware qualification phase. This paper acquaints spacecraft designers with the design and performance capabilities of the HD- 1003 tracker. We highlight the tracker's unique features which include: (1) Very small size (165 cu. in.). (2) Low weight (7 lbs). (3) Multi-star tracking (6 stars simultaneously). (4) Eighteen arc-sec (3-sigma) accuracy. (5) Growth margin for `all-stellar' attitude reference.

  11. Development of an optimal filter substrate for the identification of small microplastic particles in food by micro-Raman spectroscopy.

    PubMed

    Oßmann, Barbara E; Sarau, George; Schmitt, Sebastian W; Holtmannspötter, Heinrich; Christiansen, Silke H; Dicke, Wilhelm

    2017-06-01

    When analysing microplastics in food, due to toxicological reasons it is important to achieve clear identification of particles down to a size of at least 1 μm. One reliable, optical analytical technique allowing this is micro-Raman spectroscopy. After isolation of particles via filtration, analysis is typically performed directly on the filter surface. In order to obtain high qualitative Raman spectra, the material of the membrane filters should not show any interference in terms of background and Raman signals during spectrum acquisition. To facilitate the usage of automatic particle detection, membrane filters should also show specific optical properties. In this work, beside eight different, commercially available membrane filters, three newly designed metal-coated polycarbonate membrane filters were tested to fulfil these requirements. We found that aluminium-coated polycarbonate membrane filters had ideal characteristics as a substrate for micro-Raman spectroscopy. Its spectrum shows no or minimal interference with particle spectra, depending on the laser wavelength. Furthermore, automatic particle detection can be applied when analysing the filter surface under dark-field illumination. With this new membrane filter, analytics free of interference of microplastics down to a size of 1 μm becomes possible. Thus, an important size class of these contaminants can now be visualized and spectrally identified. Graphical abstract A newly developed aluminium coated polycarbonate membrane filter enables automatic particle detection and generation of high qualitative Raman spectra allowing identification of small microplastics.

  12. A General Reliability Model for Ni-BaTiO3-Based Multilayer Ceramic Capacitors

    NASA Technical Reports Server (NTRS)

    Liu, Donhang

    2014-01-01

    The evaluation of multilayer ceramic capacitors (MLCCs) with Ni electrode and BaTiO3 dielectric material for potential space project applications requires an in-depth understanding of their reliability. A general reliability model for Ni-BaTiO3 MLCC is developed and discussed. The model consists of three parts: a statistical distribution; an acceleration function that describes how a capacitor's reliability life responds to the external stresses, and an empirical function that defines contribution of the structural and constructional characteristics of a multilayer capacitor device, such as the number of dielectric layers N, dielectric thickness d, average grain size, and capacitor chip size A. Application examples are also discussed based on the proposed reliability model for Ni-BaTiO3 MLCCs.

  13. A General Reliability Model for Ni-BaTiO3-Based Multilayer Ceramic Capacitors

    NASA Technical Reports Server (NTRS)

    Liu, Donhang

    2014-01-01

    The evaluation for potential space project applications of multilayer ceramic capacitors (MLCCs) with Ni electrode and BaTiO3 dielectric material requires an in-depth understanding of the MLCCs reliability. A general reliability model for Ni-BaTiO3 MLCCs is developed and discussed in this paper. The model consists of three parts: a statistical distribution; an acceleration function that describes how a capacitors reliability life responds to external stresses; and an empirical function that defines the contribution of the structural and constructional characteristics of a multilayer capacitor device, such as the number of dielectric layers N, dielectric thickness d, average grain size r, and capacitor chip size A. Application examples are also discussed based on the proposed reliability model for Ni-BaTiO3 MLCCs.

  14. CSP Manufacturing Challenges and Assembly Reliability

    NASA Technical Reports Server (NTRS)

    Ghaffarian, Reza

    2000-01-01

    Although the expression of CSP is widely used by industry from suppliers to users, its implied definition had evolved as the technology has matured. There are "expert definition"- package that is up to 1.5 time die- or "interim definition". CSPs are miniature new packages that industry is starting to implement and there are many unresolved technical issues associated with their implementation. For example, in early 1997, packages with 1 mm pitch and lower were the dominant CSPs, whereas in early 1998 packages with 0.8 mm and lower became the norm for CSPs. Other changes included the use of flip chip die rather than wire bond in CSP. Nonetheless the emerging CSPs are competing with bare die assemblies and are becoming the package of choice for size reduction applications. These packages provide the benefits of small size and performance of the bare die or flip chip, with the advantage of standard die packages. The JPL-led MicrotypeBGA Consortium of enterprises representing government agencies and private companies have jointed together to pool in-kind resources for developing the quality and reliability of chip scale packages (CSPs) for a variety of projects. This talk will cover specifically the experience of our consortium on technology implementation challenges, including design and build of both standard and microvia boards, assembly of two types of test vehicles, and the most current environmental thermal cycling test results.

  15. Convolutional neural network guided blue crab knuckle detection for autonomous crab meat picking machine

    NASA Astrophysics Data System (ADS)

    Wang, Dongyi; Vinson, Robert; Holmes, Maxwell; Seibel, Gary; Tao, Yang

    2018-04-01

    The Atlantic blue crab is among the highest-valued seafood found in the American Eastern Seaboard. Currently, the crab processing industry is highly dependent on manual labor. However, there is great potential for vision-guided intelligent machines to automate the meat picking process. Studies show that the back-fin knuckles are robust features containing information about a crab's size, orientation, and the position of the crab's meat compartments. Our studies also make it clear that detecting the knuckles reliably in images is challenging due to the knuckle's small size, anomalous shape, and similarity to joints in the legs and claws. An accurate and reliable computer vision algorithm was proposed to detect the crab's back-fin knuckles in digital images. Convolutional neural networks (CNNs) can localize rough knuckle positions with 97.67% accuracy, transforming a global detection problem into a local detection problem. Compared to the rough localization based on human experience or other machine learning classification methods, the CNN shows the best localization results. In the rough knuckle position, a k-means clustering method is able to further extract the exact knuckle positions based on the back-fin knuckle color features. The exact knuckle position can help us to generate a crab cutline in XY plane using a template matching method. This is a pioneering research project in crab image analysis and offers advanced machine intelligence for automated crab processing.

  16. Niphargus: a silicon band-gap sensor temperature logger for high-precision environmental monitoring

    NASA Astrophysics Data System (ADS)

    Burlet, Christian; Vanbrabant, Yves; Piessens, Kris; Welkenhuysen, Kris; Verheyden, Sophie

    2014-05-01

    A temperature logger, called 'Niphargus', was developed at the Geological Survey of Belgium to monitor temperature of local natural processes with sensitivity of the order of a few hundredths of degrees to monitor temperature variability in open air, caves, soils and rivers. The newly developed instrument uses a state-of-the-art band-gap silicon temperature sensor with digital output. This sensor reduces the risk of drift associated with thermistor-based sensing devices, especially in humid environments. The Niphargus is designed to be highly reliable, low-cost and powered by a single lithium cell with up to several years autonomy depending on the sampling rate and environmental conditions. The Niphargus was evaluated in an ice point bath experiment in terms of temperature accuracy and thermal inertia. The small size and low power consumption of the logger allow its use in difficult accessible environments, e.g. caves and space-constrained applications, inside a rock in a water stream. In both cases, the loggers have proven to be reliable and accurate devices. For example, spectral analysis of the temperature signal in the Han caves (Belgium) allowed detection and isolation of a 0.005° C amplitude day-night periodic signal in the temperature curve. PIC Figure 1: a Niphargus logger in its standard size. SMD components side. Photo credit: W. Miseur

  17. 77 FR 72702 - Small Business Size Standards: Information

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-12-06

    ... SMALL BUSINESS ADMINISTRATION 13 CFR Part 121 RIN 3245-AG26 Small Business Size Standards: Information AGENCY: U.S. Small Business Administration. ACTION: Final rule. SUMMARY: The United States Small Business Administration (SBA) is increasing the receipts based small business size standards for 15...

  18. Optimal sample sizes for the design of reliability studies: power consideration.

    PubMed

    Shieh, Gwowen

    2014-09-01

    Intraclass correlation coefficients are used extensively to measure the reliability or degree of resemblance among group members in multilevel research. This study concerns the problem of the necessary sample size to ensure adequate statistical power for hypothesis tests concerning the intraclass correlation coefficient in the one-way random-effects model. In view of the incomplete and problematic numerical results in the literature, the approximate sample size formula constructed from Fisher's transformation is reevaluated and compared with an exact approach across a wide range of model configurations. These comprehensive examinations showed that the Fisher transformation method is appropriate only under limited circumstances, and therefore it is not recommended as a general method in practice. For advance design planning of reliability studies, the exact sample size procedures are fully described and illustrated for various allocation and cost schemes. Corresponding computer programs are also developed to implement the suggested algorithms.

  19. The transit of dosage forms through the small intestine.

    PubMed

    Yuen, Kah-Hay

    2010-08-16

    The human small intestine, with its enormous absorptive surface area, is invariably the principal site of drug absorption. Hence, the residence time of a dosage form in this part of the gut can have a great influence on the absorption of the contained drug. Various methods have been employed to monitor the gastrointestinal transit of pharmaceutical dosage forms, but the use of gamma-scintigraphy has superceded all the other methods. However, careful consideration of the time interval for image acquisition and proper analysis of the scintigraphic data are important for obtaining reliable results. Most studies reported the mean small intestinal transit time of various dosage forms to be about 3-4h, being closely similar to that of food and water. The value does not appear to be influenced by their physical state nor the presence of food, but the timing of food intake following administration of the dosage forms can influence the small intestinal transit time. While the mean small intestinal transit time is quite consistent among dosage forms and studies, individual values can vary widely. There are differing opinions regarding the effect of density and size of dosage forms on their small intestinal transit properties. Some common excipients employed in pharmaceutical formulations can affect the small intestinal transit and drug absorption. There is currently a lack of studies regarding the effects of excipients, as well as the timing of food intake on the small intestinal transit of dosage forms and drug absorption. Copyright (c) 2010 Elsevier B.V. All rights reserved.

  20. Standard semiconductor packaging for high-reliability low-cost MEMS applications

    NASA Astrophysics Data System (ADS)

    Harney, Kieran P.

    2005-01-01

    Microelectronic packaging technology has evolved over the years in response to the needs of IC technology. The fundamental purpose of the package is to provide protection for the silicon chip and to provide electrical connection to the circuit board. Major change has been witnessed in packaging and today wafer level packaging technology has further revolutionized the industry. MEMS (Micro Electro Mechanical Systems) technology has created new challenges for packaging that do not exist in standard ICs. However, the fundamental objective of MEMS packaging is the same as traditional ICs, the low cost and reliable presentation of the MEMS chip to the next level interconnect. Inertial MEMS is one of the best examples of the successful commercialization of MEMS technology. The adoption of MEMS accelerometers for automotive airbag applications has created a high volume market that demands the highest reliability at low cost. The suppliers to these markets have responded by exploiting standard semiconductor packaging infrastructures. However, there are special packaging needs for MEMS that cannot be ignored. New applications for inertial MEMS devices are emerging in the consumer space that adds the imperative of small size to the need for reliability and low cost. These trends are not unique to MEMS accelerometers. For any MEMS technology to be successful the packaging must provide the basic reliability and interconnection functions, adding the least possible cost to the product. This paper will discuss the evolution of MEMS packaging in the accelerometer industry and identify the main issues that needed to be addressed to enable the successful commercialization of the technology in the automotive and consumer markets.

  1. Standard semiconductor packaging for high-reliability low-cost MEMS applications

    NASA Astrophysics Data System (ADS)

    Harney, Kieran P.

    2004-12-01

    Microelectronic packaging technology has evolved over the years in response to the needs of IC technology. The fundamental purpose of the package is to provide protection for the silicon chip and to provide electrical connection to the circuit board. Major change has been witnessed in packaging and today wafer level packaging technology has further revolutionized the industry. MEMS (Micro Electro Mechanical Systems) technology has created new challenges for packaging that do not exist in standard ICs. However, the fundamental objective of MEMS packaging is the same as traditional ICs, the low cost and reliable presentation of the MEMS chip to the next level interconnect. Inertial MEMS is one of the best examples of the successful commercialization of MEMS technology. The adoption of MEMS accelerometers for automotive airbag applications has created a high volume market that demands the highest reliability at low cost. The suppliers to these markets have responded by exploiting standard semiconductor packaging infrastructures. However, there are special packaging needs for MEMS that cannot be ignored. New applications for inertial MEMS devices are emerging in the consumer space that adds the imperative of small size to the need for reliability and low cost. These trends are not unique to MEMS accelerometers. For any MEMS technology to be successful the packaging must provide the basic reliability and interconnection functions, adding the least possible cost to the product. This paper will discuss the evolution of MEMS packaging in the accelerometer industry and identify the main issues that needed to be addressed to enable the successful commercialization of the technology in the automotive and consumer markets.

  2. Safari Science: Assessing the reliability of citizen science data for wildlife surveys

    USGS Publications Warehouse

    Steger, Cara; Butt, Bilal; Hooten, Mevin B.

    2017-01-01

    Protected areas are the cornerstone of global conservation, yet financial support for basic monitoring infrastructure is lacking in 60% of them. Citizen science holds potential to address these shortcomings in wildlife monitoring, particularly for resource-limited conservation initiatives in developing countries – if we can account for the reliability of data produced by volunteer citizen scientists (VCS).This study tests the reliability of VCS data vs. data produced by trained ecologists, presenting a hierarchical framework for integrating diverse datasets to assess extra variability from VCS data.Our results show that while VCS data are likely to be overdispersed for our system, the overdispersion varies widely by species. We contend that citizen science methods, within the context of East African drylands, may be more appropriate for species with large body sizes, which are relatively rare, or those that form small herds. VCS perceptions of the charisma of a species may also influence their enthusiasm for recording it.Tailored programme design (such as incentives for VCS) may mitigate the biases in citizen science data and improve overall participation. However, the cost of designing and implementing high-quality citizen science programmes may be prohibitive for the small protected areas that would most benefit from these approaches.Synthesis and applications. As citizen science methods continue to gain momentum, it is critical that managers remain cautious in their implementation of these programmes while working to ensure methods match data purpose. Context-specific tests of citizen science data quality can improve programme implementation, and separate data models should be used when volunteer citizen scientists' variability differs from trained ecologists' data. Partnerships across protected areas and between protected areas and other conservation institutions could help to cover the costs of citizen science programme design and implementation.

  3. 77 FR 8020 - Semiannual Regulatory Agenda

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-02-13

    ... Size 3245-AG25 Standards for Utilities Industries. 463 Small Business Size 3245-AG26 Standards... Remediation Services Industries. 465 Small Business Size 3245-AG28 Standards: Real Estate, Rental and Leasing Industries. 466 Small Business Size 3245-AG29 Standards: Educational Services Industries. 467 Small Business...

  4. Reliability and validity of food portion size estimation from images using manual flexible digital virtual meshes

    USDA-ARS?s Scientific Manuscript database

    The eButton takes frontal images at 4 second intervals throughout the day. A three-dimensional (3D) manually administered wire mesh procedure has been developed to quantify portion sizes from the two-dimensional (2D) images. This paper reports a test of the interrater reliability and validity of use...

  5. Small genomes and large seeds: chromosome numbers, genome size and seed mass in diploid Aesculus species (Sapindaceae).

    PubMed

    Krahulcová, Anna; Trávnícek, Pavel; Krahulec, František; Rejmánek, Marcel

    2017-04-01

    Aesculus L. (horse chestnut, buckeye) is a genus of 12-19 extant woody species native to the temperate Northern Hemisphere. This genus is known for unusually large seeds among angiosperms. While chromosome counts are available for many Aesculus species, only one has had its genome size measured. The aim of this study is to provide more genome size data and analyse the relationship between genome size and seed mass in this genus. Chromosome numbers in root tip cuttings were confirmed for four species and reported for the first time for three additional species. Flow cytometric measurements of 2C nuclear DNA values were conducted on eight species, and mean seed mass values were estimated for the same taxa. The same chromosome number, 2 n = 40, was determined in all investigated taxa. Original measurements of 2C values for seven Aesculus species (eight taxa), added to just one reliable datum for A. hippocastanum , confirmed the notion that the genome size in this genus with relatively large seeds is surprisingly low, ranging from 0·955 pg 2C -1 in A. parviflora to 1·275 pg 2C -1 in A. glabra var. glabra. The chromosome number of 2 n = 40 seems to be conclusively the universal 2 n number for non-hybrid species in this genus. Aesculus genome sizes are relatively small, not only within its own family, Sapindaceae, but also within woody angiosperms. The genome sizes seem to be distinct and non-overlapping among the four major Aesculus clades. These results provide an extra support for the most recent reconstruction of Aesculus phylogeny. The correlation between the 2C values and seed masses in examined Aesculus species is slightly negative and not significant. However, when the four major clades are treated separately, there is consistent positive association between larger genome size and larger seed mass within individual lineages. © The Author 2017. Published by Oxford University Press on behalf of the Annals of Botany Company. All rights reserved. For Permissions, please email: journals.permissions@oup.com

  6. 75 FR 61597 - Small Business Size Standards: Retail Trade

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-10-06

    ... SMALL BUSINESS ADMINISTRATION 13 CFR Part 121 RIN 3245-AF69 Small Business Size Standards: Retail Trade AGENCY: U.S. Small Business Administration. ACTION: Final rule. SUMMARY: The United States Small Business Administration (SBA) is modifying 47 small business size standards for industries in North...

  7. 75 FR 61591 - Small Business Size Standards; Other Services.

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-10-06

    ... SMALL BUSINESS ADMINISTRATION 13 CFR Part 121 RIN 3245-AF70 Small Business Size Standards; Other Services. AGENCY: U.S. Small Business Administration. ACTION: Final rule. SUMMARY: The United States Small Business Administration (SBA) is increasing the small business size standards for 18 industries in North...

  8. Fishing degrades size structure of coral reef fish communities.

    PubMed

    Robinson, James P W; Williams, Ivor D; Edwards, Andrew M; McPherson, Jana; Yeager, Lauren; Vigliola, Laurent; Brainard, Russell E; Baum, Julia K

    2017-03-01

    Fishing pressure on coral reef ecosystems has been frequently linked to reductions of large fishes and reef fish biomass. Associated impacts on overall community structure are, however, less clear. In size-structured aquatic ecosystems, fishing impacts are commonly quantified using size spectra, which describe the distribution of individual body sizes within a community. We examined the size spectra and biomass of coral reef fish communities at 38 US-affiliated Pacific islands that ranged in human presence from near pristine to human population centers. Size spectra 'steepened' steadily with increasing human population and proximity to market due to a reduction in the relative biomass of large fishes and an increase in the dominance of small fishes. Reef fish biomass was substantially lower on inhabited islands than uninhabited ones, even at inhabited islands with the lowest levels of human presence. We found that on populated islands size spectra exponents decreased (analogous to size spectra steepening) linearly with declining biomass, whereas on uninhabited islands there was no relationship. Size spectra were steeper in regions of low sea surface temperature but were insensitive to variation in other environmental and geomorphic covariates. In contrast, reef fish biomass was highly sensitive to oceanographic conditions, being influenced by both oceanic productivity and sea surface temperature. Our results suggest that community size structure may be a more robust indicator than fish biomass to increasing human presence and that size spectra are reliable indicators of exploitation impacts across regions of different fish community compositions, environmental drivers, and fisheries types. Size-based approaches that link directly to functional properties of fish communities, and are relatively insensitive to abiotic variation across biogeographic regions, offer great potential for developing our understanding of fishing impacts in coral reef ecosystems. © 2016 John Wiley & Sons Ltd.

  9. The statistical properties of vortex flows in the solar atmosphere

    NASA Astrophysics Data System (ADS)

    Wedemeyer, Sven; Kato, Yoshiaki; Steiner, Oskar

    2015-08-01

    Rotating magnetic field structures associated with vortex flows on the Sun, also known as “magnetic tornadoes”, may serve as waveguides for MHD waves and transport mass and energy upwards through the atmosphere. Magnetic tornadoes may therefore potentially contribute to the heating of the upper atmospheric layers in quiet Sun regions.Magnetic tornadoes are observed over a large range of spatial and temporal scales in different layers in quiet Sun regions. However, their statistical properties such as size, lifetime, and rotation speed are not well understood yet because observations of these small-scale events are technically challenging and limited by the spatial and temporal resolution of current instruments. Better statistics based on a combination of high-resolution observations and state-of-the-art numerical simulations is the key to a reliable estimate of the energy input in the lower layers and of the energy deposition in the upper layers. For this purpose, we have developed a fast and reliable tool for the determination and visualization of the flow field in (observed) image sequences. This technique, which combines local correlation tracking (LCT) and line integral convolution (LIC), facilitates the detection and study of dynamic events on small scales, such as propagating waves. Here, we present statistical properties of vortex flows in different layers of the solar atmosphere and try to give realistic estimates of the energy flux which is potentially available for heating of the upper solar atmosphere

  10. Tagging of Test Tubes with Electronic p-Chips for Use in Biorepositories.

    PubMed

    Mandecki, Wlodek; Kopacka, Wesley M; Qian, Ziye; Ertwine, Von; Gedzberg, Katie; Gruda, Maryann; Reinhardt, David; Rodriguez, Efrain

    2017-08-01

    A system has been developed to electronically tag and track test tubes used in biorepositories. The system is based on a light-activated microtransponder, also known as a "p-Chip." One of the pressing problems with storing and retrieving biological samples at low temperatures is the difficulty of reliably reading the identification (ID) number that links each storage tube with the database containing sample details. Commonly used barcodes are not always reliable at low temperatures because of poor adhesion of the label to the test tube and problems with reading under conditions of frost and ice accumulation. Traditional radio frequency identification (RFID) tags are not cost effective and are too large for this application. The system described herein consists of the p-Chip, p-Chip-tagged test tubes, two ID readers (for single tubes or for racks of tubes), and software. We also describe a robot that is configured for retrofitting legacy test tubes in biorepositories with p-Chips while maintaining the temperature of the sample below -50°C at all times. The main benefits of the p-Chip over other RFID devices are its small size (600 × 600 × 100 μm) that allows even very small tubes or vials to be tagged, low cost due to the chip's unitary construction, durability, and the ability to read the ID through frost and ice.

  11. Linking THEMIS Orbital Data to MSL GTS Measurements: The Thermophysical Properties of the Bagnold Dunes, Mars

    NASA Astrophysics Data System (ADS)

    Edwards, C. S.; Piqueux, S.; Hamilton, V. E.; Fergason, R. L.; Herkenhoff, K. E.; Vasavada, A. R.; Sacks, L. E.; Lewis, K. W.; Smith, M. D.

    2017-12-01

    The surface of Mars has been characterized using orbital thermal infrared observations from the time of the Mariner 9 and Viking missions. More recent observations from missions such as the Thermal Emission Spectrometer onboard the Mars Global Surveyor and the Thermal Emission Imaging System (THEMIS) instrument onboard the 2001 Mars Odyssey orbiter have continued to expand global coverage at progressively higher resolution. THEMIS has been producing 100 m/pixel thermal infrared data with nearly global coverage of the surface for >15 years and has enabled new investigations that successfully link outcrop-scale information to physical properties of the surface. However, significant discrepancies between morphologies and interpreted surface properties derived from orbital thermal measurements remain, requiring a robust link to direct surface measurements. Here, we compare the thermophysical properties and particle sizes derived from the Mars Science Laboratory (MSL) rover's Ground Temperature Sensor (GTS), to those derived orbitally from THEMIS, ultimately linking these measurements to ground truth particle sizes determined from Mars Hand Lens Imager (MAHLI) images. We focus on the relatively homogenous Bagnold dunes, specifically Namib dune, and in general find that all three datasets report consistent particle sizes for the Bagnold dunes ( 110-350 µm, and are within measurement and model uncertainties), indicating that particles sizes of homogeneous materials determined from thermal measurements are reliable. In addition, we assess several potentially significant effects that could influence the derived particle sizes, including: 1) fine-scale (cm-m scale) ripples, and 2) thin (mm-cm) layering of indurated/armored materials. To first order, we find that small scale ripples and thin layers do not significantly affect the determination of bulk thermal inertia determined from orbit. However, a layer of coarser/indurated material and/or fine-scale layering does change the shape of a diurnal curve and thus requires multiple time of day observations to constrain these effects. In summary, thermal inertia and grain sizes of relatively homogeneous materials derived from nighttime orbital data should be considered as reliable, as long as there is not significant sub-pixel anisothermality.

  12. Reconstruction of oral cavity defects with FAMM (facial artery musculomucosal) flaps. Our experience.

    PubMed

    Sumarroca, Anna; Rodríguez-Bauzà, Elena; Vega, Carmen; Fernández, Manuel; Masià, Jaume; Quer, Miquel; León, Xavier

    2015-01-01

    The facial artery musculomucosal (FAMM) flap is a good option for covering small and medium-sized defects in the oral cavity because of its similar tissue characteristics and easy implementation. We reviewed our results using this flap between 2006 and 2014. A total of 20 patients were included and 25 FAMM flaps were performed, 16 right (64%) and 9 left (36%) flaps. Five patients had simultaneous bilateral reconstructions. The indications for flap surgery were reconstruction after resection of tumours in the floor of the mouth (8 cases, 40%), tumours in other sites of the oral cavity (4 cases, 20%), mandibular osteoradionecrosis (4 cases, 20%), oroantral fistula (3 cases, 15%) and postoperative ankyloglossia (one case, 5%). Reconstruction was successful in 92% of cases (n=23). Total flap necrosis occurred in one case and dehiscence with exposure of bone in another. Oral function and ingestion were satisfactory in all patients. The facial artery musculomucosal flap is reliable and versatile for reconstruction of small and medium-sized intraoral defects. It allows functional reconstruction of the oral cavity with a low risk of complications. Copyright © 2014 Elsevier España, S.L.U. y Sociedad Española de Otorrinolaringología y Patología Cérvico-Facial. All rights reserved.

  13. Ediacaran discs from South America: probable soft-bodied macrofossils unlock the paleogeography of the Clymene Ocean.

    PubMed

    Arrouy, María Julia; Warren, Lucas V; Quaglio, Fernanda; Poiré, Daniel G; Simões, Marcello Guimarães; Rosa, Milena Boselli; Peral, Lucía E Gómez

    2016-07-27

    The origin, affinity and paleoecology of macrofossils of soft-bodied organisms of the terminal Ediacaran Period have been highly debated. Previous discoveries in South America are restricted to small shelly metazoans of the Nama Assemblage. Here we report for the first time the occurrence of discoidal structures from the Upper Ediacaran Cerro Negro Formation, La Providencia Group, Argentina. Specimens are preserved in tabular sandstones with microbially-induced sedimentary structures. Flute marks and linear scours at the base of the sandstone layers indicate deposition under high energy, episodic flows. Stratigraphic, sedimentologic, petrographic and taphonomic analyses indicate that the origin of these structures is not related to abiotic process. Preservational and morphological features, as invagination and the presence of radial grooves, indicate that they resemble typical morphs of the Aspidella plexus. The large number of small-sized individuals and the wide range of size classes with skewed distribution suggest that they lived in high-density communities. The presence of Aspidella in the Cerro Negro Formation would represent the first reliable record of Ediacaran soft-bodied organisms in South America. It also supports the paleogeographic scenario of the Clymene Ocean, in which a shallow sea covered part of the southwest Gondwana at the end of the Ediacaran.

  14. Ediacaran discs from South America: probable soft-bodied macrofossils unlock the paleogeography of the Clymene Ocean

    PubMed Central

    Arrouy, María Julia; Warren, Lucas V.; Quaglio, Fernanda; Poiré, Daniel G.; Simões, Marcello Guimarães; Rosa, Milena Boselli; Peral, Lucía E. Gómez

    2016-01-01

    The origin, affinity and paleoecology of macrofossils of soft-bodied organisms of the terminal Ediacaran Period have been highly debated. Previous discoveries in South America are restricted to small shelly metazoans of the Nama Assemblage. Here we report for the first time the occurrence of discoidal structures from the Upper Ediacaran Cerro Negro Formation, La Providencia Group, Argentina. Specimens are preserved in tabular sandstones with microbially-induced sedimentary structures. Flute marks and linear scours at the base of the sandstone layers indicate deposition under high energy, episodic flows. Stratigraphic, sedimentologic, petrographic and taphonomic analyses indicate that the origin of these structures is not related to abiotic process. Preservational and morphological features, as invagination and the presence of radial grooves, indicate that they resemble typical morphs of the Aspidella plexus. The large number of small-sized individuals and the wide range of size classes with skewed distribution suggest that they lived in high-density communities. The presence of Aspidella in the Cerro Negro Formation would represent the first reliable record of Ediacaran soft-bodied organisms in South America. It also supports the paleogeographic scenario of the Clymene Ocean, in which a shallow sea covered part of the southwest Gondwana at the end of the Ediacaran. PMID:27460966

  15. Hybrid Propulsion Technology Program

    NASA Technical Reports Server (NTRS)

    Jensen, G. E.; Holzman, A. L.

    1990-01-01

    Future launch systems of the United States will require improvements in booster safety, reliability, and cost. In order to increase payload capabilities, performance improvements are also desirable. The hybrid rocket motor (HRM) offers the potential for improvements in all of these areas. The designs are presented for two sizes of hybrid boosters, a large 4.57 m (180 in.) diameter booster duplicating the Advanced Solid Rocket Motor (ASRM) vacuum thrust-time profile and smaller 2.44 m (96 in.), one-quater thrust level booster. The large booster would be used in tandem, while eight small boosters would be used to achieve the same total thrust. These preliminary designs were generated as part of the NASA Hybrid Propulsion Technology Program. This program is the first phase of an eventual three-phaes program culminating in the demonstration of a large subscale engine. The initial trade and sizing studies resulted in preferred motor diameters, operating pressures, nozzle geometry, and fuel grain systems for both the large and small boosters. The data were then used for specific performance predictions in terms of payload and the definition and selection of the requirements for the major components: the oxidizer feed system, nozzle, and thrust vector system. All of the parametric studies were performed using realistic fuel regression models based upon specific experimental data.

  16. Technological progress in sealed lead/acid batteries

    NASA Astrophysics Data System (ADS)

    Yamashita, J.; Nakashima, H.; Kasai, Y.

    A brief review is given of the history of the research and development of sealed lead/acid batteries during the 30 years since, in 1959, the Yuasa Battery Co. introduced a small-sized sealed battery as the power supply for portable television sets. In 1965, Yuasa began the full-scale mass production and sale of a small-sized sealed lead/acid battery under the NOYPER brand. In 1970, the use of a PbCa alloy grid was adopted, and there followed the successful development of a sealed battery with an oxygen-recombination facility. In 1976, Yuasa more or less established the basic technology for the valve-regulated sealed lead/acid battery — the NP battery — which is now the type in general use. Throughout the 1980s, Yuasa, has continued development in order to expand the sphere of application for the production technology of valve-regulated batteries for motorcycles, as well as for stationary duties with large capacities of 100 to 3000 A h. Recently, in order to improve the reliability and boost the output of sealed lead/acid batteries for employment in UPS power sources, Yuasa has been working intently on the design of a valve-regulated lead/acid battery with outstanding characteristics for high-rate discharge and resistance to high temperatures.

  17. A character demonstrating the occurrence of mating in male Cactoblastis cactorum (Lepidoptera: Pyralidae)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Marti, O.G.; Carpenter, J.E.

    The reproductive system of adult male Cactoblastis cactorum, the cactus moth, was examined to determine whether the mating status of males could be ascertained. In unmated males, the posterior portion of the primary ductus ejaculatorius simplex is opaque yellow in color and contains many small football-shaped hyaline granules 3-5 x 5-10 {mu}m in size. In mated males, the posterior simplex is clear and contains no granules. The presence or absence of these characters was found to be highly reliable and should be of value in determining mating status in marked-recaptured males of this species in a sterile insect release programmore » directed against Cactoblastis. (author)« less

  18. Segmented all-electron Gaussian basis sets of double and triple zeta qualities for Fr, Ra, and Ac

    NASA Astrophysics Data System (ADS)

    Campos, C. T.; de Oliveira, A. Z.; Ferreira, I. B.; Jorge, F. E.; Martins, L. S. C.

    2017-05-01

    Segmented all-electron basis sets of valence double and triple zeta qualities plus polarization functions for the elements Fr, Ra, and Ac are generated using non-relativistic and Douglas-Kroll-Hess (DKH) Hamiltonians. The sets are augmented with diffuse functions with the purpose to describe appropriately the electrons far from the nuclei. At the DKH-B3LYP level, first atomic ionization energies and bond lengths, dissociation energies, and polarizabilities of a sample of diatomics are calculated. Comparison with theoretical and experimental data available in the literature is carried out. It is verified that despite the small sizes of the basis sets, they are yet reliable.

  19. Design of portable valuables touch alarm circuit

    NASA Astrophysics Data System (ADS)

    Li, Biqing; Li, Zhao

    2017-03-01

    In this paper, the name of the alarm is portable touch burglar alarm. It not only has the advantages of high sensitivity, small size and light weight, but it is easy on the trigger, the circuit is simple and easy to be implemented, besides, it works stably. This alarm is featured with simple design, convenient use, strong flexibility and reliable performance, thus it can be installed on the door or window and even can be carried on human's body. When the human body touches the metal valuables that need to be protected, the device will start the alarm equipment so as to make the bell keep ringing, and the alarm sound stops until the power is cut off.

  20. Research and Development of Laser Diode Based Instruments for Applications in Space

    NASA Technical Reports Server (NTRS)

    Krainak, Michael; Abshire, James; Cornwell, Donald; Dragic, Peter; Duerksen, Gary; Switzer, Gregg

    1999-01-01

    Laser diode technology continues to advance at a very rapid rate due to commercial applications such as telecommunications and data storage. The advantages of laser diodes include, wide diversity of wavelengths, high efficiency, small size and weight and high reliability. Semiconductor and fiber optical-amplifiers permit efficient, high power master oscillator power amplifier (MOPA) transmitter systems. Laser diode systems which incorporate monolithic or discrete (fiber optic) gratings permit single frequency operation. We describe experimental and theoretical results of laser diode based instruments currently under development at NASA Goddard Space Flight Center including miniature lidars for measuring clouds and aerosols, water vapor and wind for Earth and planetary (Mars Lander) use.

  1. Nano-JASMINE: current status and data output

    NASA Astrophysics Data System (ADS)

    Kobayashi, Yukiyasu; Yano, Taihei; Gouda, Naoteru; Niwa, Yoshito; Murooka, Jyunpei; Yamada, Yoshiyuki; Sako, Nobutada; Nakasuka, Shin'ichi

    2010-07-01

    The current status of the Nano-JASMINE project is reported. Nano-JASMINE is a very small-sized (50 cm cubic form) satellite that is expected to carry out astrometric observations of nearby bright stars. The satellite will determine distances of more than 8000 stars by performing annual parallax measurements, which is the only direct method to measure the distance of an astronomical object. The mission is required to continue for more than two years to obtain reliable annual parallax measurements. In addition, Nano-JASMINE will serve as a preliminary to the main JASMINE mission. We expect that Nano-JASMINE will be launched in August 2011 from the Alcantara Space Center in Brazil using the Cyclone-4 rocket.

  2. Probing Gap Plasmons Down to Subnanometer Scales Using Collapsible Nanofingers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Song, Boxiang; Yao, Yuhan; Groenewald, Roelof E.

    Gap plasmonic nanostructures are of great interest due to their ability to concentrate light into small volumes. Theoretical studies, considering quantum mechanical effects, have predicted the optimal spatial gap between adjacent nanoparticles to be in the subnanometer regime in order to achieve the strongest possible field enhancement. In this paper, we present a technology to fabricate gap plasmonic structures with subnanometer resolution, high reliability, and high throughput using collapsible nanofingers. This approach enables us to systematically investigate the effects of gap size and tunneling barrier height. Finally, the experimental results are consistent with previous findings as well as with amore » straightforward theoretical model that is presented here.« less

  3. Probing Gap Plasmons Down to Subnanometer Scales Using Collapsible Nanofingers

    DOE PAGES

    Song, Boxiang; Yao, Yuhan; Groenewald, Roelof E.; ...

    2017-06-09

    Gap plasmonic nanostructures are of great interest due to their ability to concentrate light into small volumes. Theoretical studies, considering quantum mechanical effects, have predicted the optimal spatial gap between adjacent nanoparticles to be in the subnanometer regime in order to achieve the strongest possible field enhancement. In this paper, we present a technology to fabricate gap plasmonic structures with subnanometer resolution, high reliability, and high throughput using collapsible nanofingers. This approach enables us to systematically investigate the effects of gap size and tunneling barrier height. Finally, the experimental results are consistent with previous findings as well as with amore » straightforward theoretical model that is presented here.« less

  4. New distributed radar technology based on UAV or UGV application

    NASA Astrophysics Data System (ADS)

    Molchanov, Pavlo A.; Contarino, Vincent M.

    2013-05-01

    Regular micro and nano radars cannot provide reliable tracking of low altitude low profile aerial targets in urban and mountain areas because of reflection and re-reflections from buildings and terrain. They become visible and vulnerable to guided missiles if positioned on a tower or blimp. Doppler radar cannot distinguish moving cars and small low altitude aerial targets in an urban area. A new concept of pocket size distributed radar technology based on the application of UAV (Unmanned Air Vehicles), UGV (Unmanned Ground Vehicles) is proposed for tracking of low altitude low profile aerial targets at short and medium distances for protection of stadium, camp, military facility in urban or mountain areas.

  5. A simulation model for risk assessment of turbine wheels

    NASA Technical Reports Server (NTRS)

    Safie, Fayssal M.; Hage, Richard T.

    1991-01-01

    A simulation model has been successfully developed to evaluate the risk of the Space Shuttle auxiliary power unit (APU) turbine wheels for a specific inspection policy. Besides being an effective tool for risk/reliability evaluation, the simulation model also allows the analyst to study the trade-offs between wheel reliability, wheel life, inspection interval, and rejection crack size. For example, in the APU application, sensitivity analysis results showed that the wheel life limit has the least effect on wheel reliability when compared to the effect of the inspection interval and the rejection crack size. In summary, the simulation model developed represents a flexible tool to predict turbine wheel reliability and study the risk under different inspection policies.

  6. A simulation model for risk assessment of turbine wheels

    NASA Astrophysics Data System (ADS)

    Safie, Fayssal M.; Hage, Richard T.

    A simulation model has been successfully developed to evaluate the risk of the Space Shuttle auxiliary power unit (APU) turbine wheels for a specific inspection policy. Besides being an effective tool for risk/reliability evaluation, the simulation model also allows the analyst to study the trade-offs between wheel reliability, wheel life, inspection interval, and rejection crack size. For example, in the APU application, sensitivity analysis results showed that the wheel life limit has the least effect on wheel reliability when compared to the effect of the inspection interval and the rejection crack size. In summary, the simulation model developed represents a flexible tool to predict turbine wheel reliability and study the risk under different inspection policies.

  7. Universal first-order reliability concept applied to semistatic structures

    NASA Technical Reports Server (NTRS)

    Verderaime, V.

    1994-01-01

    A reliability design concept was developed for semistatic structures which combines the prevailing deterministic method with the first-order reliability method. The proposed method surmounts deterministic deficiencies in providing uniformly reliable structures and improved safety audits. It supports risk analyses and reliability selection criterion. The method provides a reliability design factor derived from the reliability criterion which is analogous to the current safety factor for sizing structures and verifying reliability response. The universal first-order reliability method should also be applicable for air and surface vehicles semistatic structures.

  8. Universal first-order reliability concept applied to semistatic structures

    NASA Astrophysics Data System (ADS)

    Verderaime, V.

    1994-07-01

    A reliability design concept was developed for semistatic structures which combines the prevailing deterministic method with the first-order reliability method. The proposed method surmounts deterministic deficiencies in providing uniformly reliable structures and improved safety audits. It supports risk analyses and reliability selection criterion. The method provides a reliability design factor derived from the reliability criterion which is analogous to the current safety factor for sizing structures and verifying reliability response. The universal first-order reliability method should also be applicable for air and surface vehicles semistatic structures.

  9. 78 FR 37404 - Small Business Size Standards: Support Activities for Mining

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-06-20

    ... SMALL BUSINESS ADMINISTRATION 13 CFR Part 121 RIN 3245-AG44 Small Business Size Standards: Support Activities for Mining AGENCY: U.S. Small Business Administration. ACTION: Final rule. SUMMARY: The United States Small Business Administration (SBA) is increasing the small business size standards for three of...

  10. 76 FR 69154 - Small Business Size and Status Integrity

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-11-08

    ... SMALL BUSINESS ADMINISTRATION 13 CFR Parts 121, 124, 125, 126, and 127 RIN 3245-AG23 Small Business Size and Status Integrity AGENCY: U.S. Small Business Administration (SBA). ACTION: Proposed rule... implement provisions of the Small Business Jobs Act of 2010 (Jobs Act) pertaining to small business size and...

  11. 48 CFR 52.219-21 - Small Business Size Representation for Targeted Industry Categories Under the Small Business...

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 48 Federal Acquisition Regulations System 2 2010-10-01 2010-10-01 false Small Business Size Representation for Targeted Industry Categories Under the Small Business Competitiveness Demonstration Program....219-21 Small Business Size Representation for Targeted Industry Categories Under the Small Business...

  12. Using Economic Experiments to Test the Effect of Reliability Pricing and Self-Sizing on the Private Provision of a Public Good Results: The Case of Constructing Water Conveyance Infrastructure to Mitigate Water Quantity and Quality Concerns in the Sacramento-San Joaquin Delta

    NASA Astrophysics Data System (ADS)

    Kaplan, J.; Howitt, R. E.; Kroll, S.

    2016-12-01

    Public financing of public projects is becoming more difficult with growing political and financial pressure to reduce the size and scope of government action. Private provision is possible but is often doomed by under-provision. If however, market-like mechanisms could be incorporated into the solicitation of funds to finance the provision of the good, because, for example, the good is supplied stochastically and is divisible, then we would expect fewer incentives to free ride and greater efficiency in providing the public good. In a controlled computer-based economic experiment, we evaluate two market-like conditions (reliability pricing allocation and self-sizing of the good) that are designed to reduce under-provision. The results suggest that financing an infrastructure project when the delivery is allocated based on reliability pricing rather than historical allocation results in significantly greater price formation efficiency and less free riding whether the project is of a fixed size determined by external policy makers or determined endogenously by the sum of private contributions. When reliability pricing and self-sizing (endogenous) mechanism are used in combination free-riding is reduced the greatest among the tested treatments. Furthermore, and as expected, self-sizing when combined with historical allocations results in the worst level of free-riding. This setting for this treatment creates an incentive to undervalue willingness to pay since very low contributions still return positive earnings as long as enough contributions are raised for a single unit. If everyone perceives everyone else is undervaluing their contribution the incentive grows stronger and we see the greatest degree of free riding among the treatments. Lastly, the results from the analysis suggested that the rebate rule may have encouraged those with willingness to pay values less than the cost of the project to feel confident when contributing more than their willingness to pay and to do so when they faced the endogenously-sized, reliability pricing solicitation since a rebate would likely return them positive earnings. In subsequent research we would like to explore the role of the rebate rule in the effectiveness of reliability pricing and self-sizing in increasing price-formation efficiency and reduce free riding.

  13. The influence of micropore size on the mechanical properties of bulk hydroxyapatite and hydroxyapatite scaffolds.

    PubMed

    Cordell, Jacqueline M; Vogl, Michelle L; Wagoner Johnson, Amy J

    2009-10-01

    While recognized as a promising bone substitute material, hydroxyapatite (HA) has had limited use in clinical settings because of its inherent brittle behavior. It is well established that macropores ( approximately 100 microm) in a HA implant, or scaffold, are required for bone ingrowth, but recent research has shown that ingrowth is enhanced when scaffolds also contain microporosity. HA is sensitive to synthesis and processing parameters and therefore characterization for specific applications is necessary for transition to the clinic. To that end, the mechanical behavior of bulk microporous HA and HA scaffolds with multi-scale porosity (macropores between rods in the range of 250-350 microm and micropores within the rods with average size of either 5.96 microm or 16.2 microm) was investigated in order to determine how strength and reliability were affected by micropore size (5.96 microm versus 16.2 microm). For the bulk microporous HA, strength increased with decreasing micropore size in both bending (19 MPa to 22 MPa) and compression (71 MPa to 110 MPa). To determine strength reliability, the Weibull moduli for the bulk microporous HA were determined. The Weibull moduli for bending increased (became more reliable) with decreasing pore size (7 to 10) while the Weibull moduli for compression decreased (became less reliable) with decreasing pore size (9 to 6). Furthermore, the elastic properties of the bulk microporous HA (elastic modulus of 30 GPa) and the compressive strengths of the HA scaffolds with multi-scale porosity (8 MPa) did not vary with pore size. The mechanisms responsible for the trends observed were discussed.

  14. An improved camera trap for amphibians, reptiles, small mammals, and large invertebrates

    USGS Publications Warehouse

    Hobbs, Michael T.; Brehme, Cheryl S.

    2017-01-01

    Camera traps are valuable sampling tools commonly used to inventory and monitor wildlife communities but are challenged to reliably sample small animals. We introduce a novel active camera trap system enabling the reliable and efficient use of wildlife cameras for sampling small animals, particularly reptiles, amphibians, small mammals and large invertebrates. It surpasses the detection ability of commonly used passive infrared (PIR) cameras for this application and eliminates problems such as high rates of false triggers and high variability in detection rates among cameras and study locations. Our system, which employs a HALT trigger, is capable of coupling to digital PIR cameras and is designed for detecting small animals traversing small tunnels, narrow trails, small clearings and along walls or drift fencing.

  15. An improved camera trap for amphibians, reptiles, small mammals, and large invertebrates.

    PubMed

    Hobbs, Michael T; Brehme, Cheryl S

    2017-01-01

    Camera traps are valuable sampling tools commonly used to inventory and monitor wildlife communities but are challenged to reliably sample small animals. We introduce a novel active camera trap system enabling the reliable and efficient use of wildlife cameras for sampling small animals, particularly reptiles, amphibians, small mammals and large invertebrates. It surpasses the detection ability of commonly used passive infrared (PIR) cameras for this application and eliminates problems such as high rates of false triggers and high variability in detection rates among cameras and study locations. Our system, which employs a HALT trigger, is capable of coupling to digital PIR cameras and is designed for detecting small animals traversing small tunnels, narrow trails, small clearings and along walls or drift fencing.

  16. Fusion positron emission/computed tomography underestimates the presence of hilar nodal metastases in patients with resected non-small cell lung cancer.

    PubMed

    Carrillo, Sergio A; Daniel, Vincent C; Hall, Nathan; Hitchcock, Charles L; Ross, Patrick; Kassis, Edmund S

    2012-05-01

    The 5-year survival for patients with resected stage II (N1) non-small cell lung cancer ranges from 40% to 55%. No data exist addressing the benefit of neoadjuvant therapy for patients with stage II disease. This is largely in part due to the lack of a reliable, minimally invasive method to assess hilar nodes. This study is aimed at determining the ability of fusion positron emission/computed tomography (PET/CT) to identify hilar metastases in patients with resected non-small cell lung cancer. A retrospective review of surgically resected patients with fusion PET/CT within 30 days of resection was performed. The sensitivity, specificity, positive predictive value, and negative predictive value for PET/CT in detecting hilar nodal metastases was calculated for a range of maximum standardized uptake values (SUVmax). Hilar nodes from patients with falsely positive PET/CT scans were analyzed for the presence of histoplasmosis. Additionally, the impact of hilar node size greater than 1 centimeter on the calculated values was assessed. There were 119 patients evaluated. The number of lymph nodes resected ranged from 1 to 12 (X=2.98). There was decreased sensitivity and increased specificity with higher SUVmax cutoff values. At the standard SUVmax value of 2.5, the sensitivity and specificity were only 48.5% and 80.2%. The addition of size of hilar node by CT led to a modest improvement in sensitivity at all SUVmax cutoff values. Fusion PET/CT lacks sensitivity and specificity in identifying hilar nodal metastasis in patients with resected non-small cell lung cancer. Further prospective studies assessing the utility of PET/CT versus alternative sampling techniques are warranted. Copyright © 2012 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  17. Testing non-inferiority of a new treatment in three-arm clinical trials with binary endpoints.

    PubMed

    Tang, Nian-Sheng; Yu, Bin; Tang, Man-Lai

    2014-12-18

    A two-arm non-inferiority trial without a placebo is usually adopted to demonstrate that an experimental treatment is not worse than a reference treatment by a small pre-specified non-inferiority margin due to ethical concerns. Selection of the non-inferiority margin and establishment of assay sensitivity are two major issues in the design, analysis and interpretation for two-arm non-inferiority trials. Alternatively, a three-arm non-inferiority clinical trial including a placebo is usually conducted to assess the assay sensitivity and internal validity of a trial. Recently, some large-sample approaches have been developed to assess the non-inferiority of a new treatment based on the three-arm trial design. However, these methods behave badly with small sample sizes in the three arms. This manuscript aims to develop some reliable small-sample methods to test three-arm non-inferiority. Saddlepoint approximation, exact and approximate unconditional, and bootstrap-resampling methods are developed to calculate p-values of the Wald-type, score and likelihood ratio tests. Simulation studies are conducted to evaluate their performance in terms of type I error rate and power. Our empirical results show that the saddlepoint approximation method generally behaves better than the asymptotic method based on the Wald-type test statistic. For small sample sizes, approximate unconditional and bootstrap-resampling methods based on the score test statistic perform better in the sense that their corresponding type I error rates are generally closer to the prespecified nominal level than those of other test procedures. Both approximate unconditional and bootstrap-resampling test procedures based on the score test statistic are generally recommended for three-arm non-inferiority trials with binary outcomes.

  18. Validity and test-retest reliability in assessing current body size with figure drawings in Chinese adolescents.

    PubMed

    Lo, Wing-Sze; Ho, Sai-Yin; Wong, Bonny Yee-Man; Mak, Kwok-Kei; Lam, Tai-Hing

    2011-06-01

    The reliability and validity of Stunkard's Figure Rating Scale (FRS) as a measure of current body size (CBS) was established in Western adolescent girls but not in non-Western population. We examined the validity and test-retest reliability of Stunkard's FRS in assessing CBS among Chinese adolescents. Methods. In a school-based survey in Hong Kong, 5666 adolescents (boys: 45.1%; mean age 14.7 years) provided data on self-reported height and weight, CBS, perceived weight status, and health-related quality of life using the Medical Outcomes Study Short-Form version 2 (SF-12v2). Height and weight were also objectively measured. Spearman's correlation was used to assess construct validity, concurrent validity and test-retest reliability. Convergent and discriminant validity were good: CBS correlated strongly with weight and self-reported/measured BMI, but only weakly with SF-12v2. CBS correlated strongly with perceived weight status, showing concurrent validity. Spearman's correlation (r) for CBS was 0.78 for girls and 0.72 for boys indicating good test-retest reliability. Validity and reliability results did not differ significantly between senior and junior grade adolescents. Our findings support the use of Stunkard's FRS to measure body size among Chinese adolescents.

  19. Assessment, development, and testing of glass for blast environments.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Glass, Sarah Jill

    2003-06-01

    Glass can have lethal effects including fatalities and injuries when it breaks and then flies through the air under blast loading (''the glass problem''). One goal of this program was to assess the glass problem and solutions being pursued to mitigate it. One solution to the problem is the development of new glass technology that allows the strength and fragmentation to be controlled or selected depending on the blast performance specifications. For example the glass could be weak and fail, or it could be strong and survive, but it must perform reliably. Also, once it fails it should produce fragmentsmore » of a controlled size. Under certain circumstances it may be beneficial to have very small fragments, in others it may be beneficial to have large fragments that stay together. The second goal of this program was to evaluate the performance (strength, reliability, and fragmentation) of Engineered Stress Profile (ESP) glass under different loading conditions. These included pseudo-static strength and pressure tests and free-field blast tests. The ultimate goal was to provide engineers and architects with a glass whose behavior under blast loading is less lethal. A near-term benefit is a new approach for improving the reliability of glass and modifying its fracture behavior.« less

  20. The Community Child Health Network Life Stress Interview: a brief chronic stress measure for community health research.

    PubMed

    Tanner Stapleton, Lynlee R; Dunkel Schetter, Christine; Dooley, Larissa N; Guardino, Christine M; Huynh, Jan; Paek, Cynthia; Clark-Kauffman, Elizabeth; Schafer, Peter; Woolard, Richard; Lanzi, Robin Gaines

    2016-07-01

    Chronic stress is implicated in many theories as a contributor to a wide range of physical and mental health problems. The current study describes the development of a chronic stress measure that was based on the UCLA Life Stress Interview (LSI) and adapted in collaboration with community partners for use in a large community health study of low-income, ethnically diverse parents of infants in the USA (Community Child Health Network [CCHN]). We describe the instrument, its purpose and adaptations, implementation, and results of a reliability study in a subsample of the larger study cohort. Interviews with 272 mothers were included in the present study. Chronic stress was assessed using the CCHN LSI, an instrument designed for administration by trained community interviewers to assess four domains of chronic stress, each rated by interviewers. Significant correlations ranging from small to moderate in size between chronic stress scores on this measure, other measures of stress, biomarkers of allostatic load, and mental health provide initial evidence of construct and concurrent validity. Reliability data for interviewer ratings are also provided. This relatively brief interview (15 minutes) is available for use and may be a valuable tool for researchers seeking to measure chronic stress reliably and validly in future studies with time constraints.

  1. Basic Concepts in Classical Test Theory: Tests Aren't Reliable, the Nature of Alpha, and Reliability Generalization as a Meta-analytic Method.

    ERIC Educational Resources Information Center

    Helms, LuAnn Sherbeck

    This paper discusses the fact that reliability is about scores and not tests and how reliability limits effect sizes. The paper also explores the classical reliability coefficients of stability, equivalence, and internal consistency. Stability is concerned with how stable test scores will be over time, while equivalence addresses the relationship…

  2. The reliability of the Australasian Triage Scale: a meta-analysis

    PubMed Central

    Ebrahimi, Mohsen; Heydari, Abbas; Mazlom, Reza; Mirhaghi, Amir

    2015-01-01

    BACKGROUND: Although the Australasian Triage Scale (ATS) has been developed two decades ago, its reliability has not been defined; therefore, we present a meta-analyis of the reliability of the ATS in order to reveal to what extent the ATS is reliable. DATA SOURCES: Electronic databases were searched to March 2014. The included studies were those that reported samples size, reliability coefficients, and adequate description of the ATS reliability assessment. The guidelines for reporting reliability and agreement studies (GRRAS) were used. Two reviewers independently examined abstracts and extracted data. The effect size was obtained by the z-transformation of reliability coefficients. Data were pooled with random-effects models, and meta-regression was done based on the method of moment’s estimator. RESULTS: Six studies were included in this study at last. Pooled coefficient for the ATS was substantial 0.428 (95%CI 0.340–0.509). The rate of mis-triage was less than fifty percent. The agreement upon the adult version is higher than the pediatric version. CONCLUSION: The ATS has shown an acceptable level of overall reliability in the emergency department, but it needs more development to reach an almost perfect agreement. PMID:26056538

  3. 77 FR 39442 - Receipts-Based, Small Business Size Standard

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-07-03

    ... RIN 3150-AJ14 [NRC-2012-0062] Receipts-Based, Small Business Size Standard AGENCY: Nuclear Regulatory... business size standard from $6.5 million to $7 million to conform to the standard set by the Small Business... updating the receipts-based, small business size standard from $6.5 million to $7.0 million. Adequate...

  4. Probabilistic sizing of laminates with uncertainties

    NASA Technical Reports Server (NTRS)

    Shah, A. R.; Liaw, D. G.; Chamis, C. C.

    1993-01-01

    A reliability based design methodology for laminate sizing and configuration for a special case of composite structures is described. The methodology combines probabilistic composite mechanics with probabilistic structural analysis. The uncertainties of constituent materials (fiber and matrix) to predict macroscopic behavior are simulated using probabilistic theory. Uncertainties in the degradation of composite material properties are included in this design methodology. A multi-factor interaction equation is used to evaluate load and environment dependent degradation of the composite material properties at the micromechanics level. The methodology is integrated into a computer code IPACS (Integrated Probabilistic Assessment of Composite Structures). Versatility of this design approach is demonstrated by performing a multi-level probabilistic analysis to size the laminates for design structural reliability of random type structures. The results show that laminate configurations can be selected to improve the structural reliability from three failures in 1000, to no failures in one million. Results also show that the laminates with the highest reliability are the least sensitive to the loading conditions.

  5. Similar reliability and equivalent performance of female and male mice in the open field and water‐maze place navigation task

    PubMed Central

    Fritz, Ann‐Kristina; Amrein, Irmgard

    2017-01-01

    Although most nervous system diseases affect women and men differentially, most behavioral studies using mouse models do not include subjects of both sexes. Many researchers worry that data of female mice may be unreliable due to the estrous cycle. Here, we retrospectively evaluated sex effects on coefficient of variation (CV) in 5,311 mice which had performed the same place navigation protocol in the water‐maze and in 4,554 mice tested in the same open field arena. Confidence intervals for Cohen's d as measure of effect size were computed and tested for equivalence with 0.2 as equivalence margin. Despite the large sample size, only few behavioral parameters showed a significant sex effect on CV. Confidence intervals of effect size indicated that CV was either equivalent or showed a small sex difference at most, accounting for less than 2% of total group to group variation of CV. While female mice were potentially slightly more variable in water‐maze acquisition and in the open field, males tended to perform less reliably in the water‐maze probe trial. In addition to evaluating variability, we also directly compared mean performance of female and male mice and found them to be equivalent in both water‐maze place navigation and open field exploration. Our data confirm and extend other large scale studies in demonstrating that including female mice in experiments does not cause a relevant increase of data variability. Our results make a strong case for including mice of both sexes whenever open field or water‐maze are used in preclinical research. PMID:28654717

  6. Similar reliability and equivalent performance of female and male mice in the open field and water-maze place navigation task.

    PubMed

    Fritz, Ann-Kristina; Amrein, Irmgard; Wolfer, David P

    2017-09-01

    Although most nervous system diseases affect women and men differentially, most behavioral studies using mouse models do not include subjects of both sexes. Many researchers worry that data of female mice may be unreliable due to the estrous cycle. Here, we retrospectively evaluated sex effects on coefficient of variation (CV) in 5,311 mice which had performed the same place navigation protocol in the water-maze and in 4,554 mice tested in the same open field arena. Confidence intervals for Cohen's d as measure of effect size were computed and tested for equivalence with 0.2 as equivalence margin. Despite the large sample size, only few behavioral parameters showed a significant sex effect on CV. Confidence intervals of effect size indicated that CV was either equivalent or showed a small sex difference at most, accounting for less than 2% of total group to group variation of CV. While female mice were potentially slightly more variable in water-maze acquisition and in the open field, males tended to perform less reliably in the water-maze probe trial. In addition to evaluating variability, we also directly compared mean performance of female and male mice and found them to be equivalent in both water-maze place navigation and open field exploration. Our data confirm and extend other large scale studies in demonstrating that including female mice in experiments does not cause a relevant increase of data variability. Our results make a strong case for including mice of both sexes whenever open field or water-maze are used in preclinical research. © 2017 The Authors. American Journal of Medical Genetics Part C Published by Wiley Periodicals, Inc.

  7. Intra- and inter-observer reliability of quantitative analysis of the infra-patellar fat pad and comparison between fat- and non-fat-suppressed imaging--Data from the osteoarthritis initiative.

    PubMed

    Steidle-Kloc, E; Wirth, W; Ruhdorfer, A; Dannhauer, T; Eckstein, F

    2016-03-01

    The infra-patellar fat pad (IPFP), as intra-articular adipose tissue represents a potential source of pro-inflammatory cytokines and its size has been suggested to be associated with osteoarthritis (OA) of the knee. This study examines inter- and intra-observer reliability of fat-suppressed (fs) and non-fat-suppressed (nfs) MR imaging for determination of IPFP morphological measurements as novel biomarkers. The IPFP of nine right knees of healthy Osteoarthritis Initiative participants was segmented by five readers, using fs and nfs baseline sagittal MRIs. The intra-observer reliability was determined from baseline and 1-year follow-up images. All segmentations were quality controlled (QC) by an expert reader. Reliability was expressed as root mean square coefficient of variation (RMS CV%). After QC, the inter-observer reliability for fs (nfs) imaging was 2.0% (1.1%) for IPFP volume, 2.1%/2.5% (1.6%/1.8%) for anterior/posterior surface areas, 1.8% (1.8%) for depth, and 2.1% (2.4%) for maximum sagittal area. The intra-observer reliability was 3.1% (5.0%) for volume, 2.3%/2.8% (2.5%/2.9%) for anterior/posterior surfaces, 1.9% (3.5%) for depth, and 3.3% (4.5%) for maximum sagittal area. IPFP volume from nfs images was systematically greater (+7.3%) than from fs images, but highly correlated (r=0.98). The results suggest that quantitative measurements of IPFP morphology can be performed with satisfactory reliability when expert QC is implemented. The IPFP is more clearly depicted in nfs images, and there is a small systematic off-set versus analysis from fs images. However, the high linear relationship between fs and nfs imaging suggests that fs images can be used to analyze IPFP morphology, when nfs images are not available. Copyright © 2015 Elsevier GmbH. All rights reserved.

  8. Intra- and inter-observer reliability of quantitative analysis of the infra-patellar fat pad and comparison between fat- and non-fat-suppressed imaging—Data from the osteoarthritis initiative

    PubMed Central

    Steidle-Kloc, E.; Wirth, W.; Ruhdorfer, A.; Dannhauer, T.; Eckstein, F.

    2015-01-01

    The infra-patellar fat pad (IPFP), as intra-articular adipose tissue represents a potential source of pro-inflammatory cytokines and its size has been suggested to be associated with osteoarthritis (OA) of the knee. This study examines inter- and intra-observer reliability of fat-suppressed (fs) and non-fat-suppressed (nfs) MR imaging for determination of IPFP morphological measurements as novel biomarkers. The IPFP of nine right knees of healthy Osteoarthritis Initiative participants was segmented by five readers, using fs and nfs baseline sagittal MRIs. The intra-observer reliability was determined from baseline and 1-year follow-up images. All segmentations were quality controlled (QC) by an expert reader. Reliability was expressed as root mean square coefficient of variation (RMS CV%). After QC, the inter-observer reliability for fs (nfs) imaging was 2.0% (1.1%) for IPFP volume, 2.1%/2.5% (1.6%/1.8%) for anterior/posterior surface areas, 1.8% (1.8%) for depth, and 2.1% (2.4%) for maximum sagittal area. The intra-observer reliability was 3.1% (5.0%) for volume, 2.3%/2.8% (2.5%/2.9%) for anterior/posterior surfaces, 1.9% (3.5%) for depth, and 3.3% (4.5%) for maximum sagittal area. IPFP volume from nfs images was systematically greater (+7.3%) than from fs images, but highly correlated (r = 0.98). The results suggest that quantitative measurements of IPFP morphology can be performed with satisfactory reliability when expert QC is implemented. The IPFP is more clearly depicted in nfs images, and there is a small systematic off-set versus analysis from fs images. However, the high linear relationship between fs and nfs imaging suggests that fs images can be used to analyze IPFP morphology, when nfs images are not available. PMID:26569532

  9. 76 FR 27952 - Small Business Size Standards: Professional, Scientific and Technical Services.

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-05-13

    ... Administration (SBA or Agency) proposed to increase small business size standards for 35 industries and one sub... SMALL BUSINESS ADMINISTRATION 13 CFR Part 121 RIN 3245-AG07 Small Business Size Standards: Professional, Scientific and Technical Services. AGENCY: U.S. Small Business Administration. ACTION: Proposed...

  10. Body shape convergence driven by small size optimum in marine angelfishes.

    PubMed

    Frédérich, Bruno; Santini, Francesco; Konow, Nicolai; Schnitzler, Joseph; Lecchini, David; Alfaro, Michael E

    2017-06-01

    Convergent evolution of small body size occurs across many vertebrate clades and may reflect an evolutionary response to shared selective pressures. However it remains unclear if other aspects of phenotype undergo convergent evolution in miniaturized lineages. Here we present a comparative analysis of body size and shape evolution in marine angelfishes (Pomacanthidae), a reef fish family characterized by repeated transitions to small body size. We ask if lineages that evolve small sizes show convergent evolution in body shape. Our results reveal that angelfish lineages evolved three different stable size optima with one corresponding to the group of pygmy angelfishes ( Centropyge ). Then, we test if the observed shifts in body size are associated with changes to new adaptive peaks in shape. Our data suggest that independent evolution to small size optima have induced repeated convergence upon deeper body and steeper head profile in Centropyge These traits may favour manoeuvrability and visual awareness in these cryptic species living among corals, illustrating that functional demands on small size may be related to habitat specialization and predator avoidance. The absence of shape convergence in large marine angelfishes also suggests that more severe requirements exist for small than for large size optima. © 2017 The Author(s).

  11. Biotemplated Synthesis of Anatase Titanium Dioxide Nanoparticles via Lignocellulosic Waste Material

    PubMed Central

    Bagheri, Samira; Abd Hamid, Sharifah Bee

    2014-01-01

    Anatase titanium dioxide nanoparticles (TiO2-NPs) were synthesized by sol-gel method using rice straw as a soft biotemplate. Rice straw, as a lignocellulosic waste material, is a biomass feedstock which is globally produced in high rate and could be utilized in an innovative approach to manufacture a value-added product. Rice straw as a reliable biotemplate has been used in the sol-gel method to synthesize ultrasmall sizes of TiO2-NPs with high potential application in photocatalysis. The physicochemical properties of titanium dioxide nanoparticles were investigated by a number of techniques such as X-ray diffraction analysis (XRD), transmission electron microscopy (TEM), Fourier transform infrared spectroscopy (FTIR), Raman spectroscopy, thermogravimetric analysis (TGA), ultraviolet visible spectra (UV-Vis), and surface area and pore size analysis. All results consensually confirmed that particle sizes of synthesized titanium dioxide were template-dependent, representing decrease in the nanoparticles sizes with increase of biotemplate concentration. Titanium dioxide nanoparticles as small as 13.0 ± 3.3 nm were obtained under our experimental conditions. Additionally, surface area and porosity of synthesized TiO2-NPs have been enhanced by increasing rice straw amount which results in surface modification of nanoparticles and potential application in photocatalysis. PMID:25126547

  12. The Consideration of Future Consequences and Health Behaviour: A Meta-Analysis.

    PubMed

    Murphy, Lisa; Dockray, Samantha

    2018-06-14

    The aim of this meta-analysis was to quantify the direction and strength of associations between the Consideration of Future Consequences (CFC) scale and intended and actual engagement in three categories of health-related behaviour: health risk, health promotive, and illness preventative/detective behaviour. A systematic literature search was conducted to identify studies that measured CFC and health behaviour. In total, sixty-four effect sizes were extracted from 53 independent samples. Effect sizes were synthesised using a random-effects model. Aggregate effect sizes for all behaviour categories were significant, albeit small in magnitude. There were no significant moderating effects of the length of CFC scale (long vs. short), population type (college students vs. non-college students), mean age, or sex proportion of study samples. CFC reliability and study quality score significantly moderated the overall association between CFC and health risk behaviour only. The magnitude of effect sizes is comparable to associations between health behaviour and other individual difference variables, such as the Big Five personality traits. The findings indicate that CFC is an important construct to consider in research on engagement in health risk behaviour in particular. Future research is needed to examine the optimal approach by which to apply the findings to behavioural interventions.

  13. Effects of Ni particle morphology on cell performance of Na/NiCl2 battery

    NASA Astrophysics Data System (ADS)

    Kim, Mangi; Ahn, Cheol-Woo; Hahn, Byung-Dong; Jung, Keeyoung; Park, Yoon-Cheol; Cho, Nam-ung; Lee, Heesoo; Choi, Joon-Hwan

    2017-11-01

    Electrochemical reaction of Ni particle, one of active cathode materials in the Na/NiCl2 battery, occurs on the particle surface. The NiCl2 layer formed on the Ni particle surface during charging can disconnect the electron conduction path through Ni particles because the NiCl2 layer has very low conductivity. The morphology and size of Ni particles, therefore, need to be controlled to obtain high charge capacity and excellent cyclic retention. Effects of the Ni particle size on the cell performance were investigated using spherical Ni particles with diameters of 0.5 μm, 6 μm, and 50 μm. The charge capacities of the cells with spherical Ni particles increased when the Ni particle size becomes smaller because of their higher surface area but their charge capacities were significantly decreased with increasing cyclic tests owing to the disconnection of electron conduction path. The inferior cyclic retention of charge capacity was improved using reticular Ni particles which maintained the reliable connection for the electron conduction in the Na/NiCl2 battery. The charge capacity of the cell with the reticular Ni particles was higher than the cell with the small-sized spherical Ni particles approximately by 26% at 30th cycle.

  14. Increasing Small Satellite Reliability- A Public-Private Initiative

    NASA Technical Reports Server (NTRS)

    Johnson, Michael A.; Beauchamp, Patricia; Schone, Harald; Sheldon, Doug; Fuhrman, Linda; Sullivan, Erica; Fairbanks, Tom; Moe, Miquel; Leitner, Jesse

    2017-01-01

    At present, CubeSat components and buses are generally not appropriate for missions where significant risk of failure, or the inability to quantify risk or confidence, is acceptable. However, in the future we anticipate that CubeSats will be used for missions requiring reliability of 1-3 years for Earth-observing missions and even longer for Planetary, Heliophysics, and Astrophysics missions. Their growing potential utility is driving an interagency effort to improve and quantify CubeSat reliability, and more generally, small satellite mission risk. The Small Satellite Reliability Initiative (SSRI)—an ongoing activity with broad collaborative participation from civil, DoD, and commercial space systems providers and stakeholders—targets this challenge. The Initiative seeks to define implementable and broadly-accepted approaches to achieve reliability and acceptable risk postures associated with several SmallSat mission risk classes—from “do no harm” missions, to those associated with missions whose failure would result in loss or delay of key national objectives. These approaches will maintain, to the extent practical, cost efficiencies associated with small satellite missions and consider constraints associated with supply chain elements, as appropriate. The SSRI addresses this challenge from two architectural levels—the mission- or system-level, and the component- or subsystem-level. The mission- or system-level scope targets assessment approaches that are efficient and effective, with mitigation strategies that facilitate resiliency to mission or system anomalies while the component- or subsystem-level scope addresses the challenge at lower architectural levels. The initiative does not limit strategies and approaches to proven and traditional methodologies, but is focused on fomenting thought on novel and innovative solutions. This paper discusses the genesis of and drivers for this initiative, how the public-private collaboration is being executed, findings and recommendations derived to date, and next steps towards broadening small satellite mission potential.

  15. Evaluation of Case Size 0603 BME Ceramic Capacitors

    NASA Technical Reports Server (NTRS)

    Teverovsky, Alexander A.

    2015-01-01

    High volumetric efficiency of commercial base metal electrode (BME) ceramic capacitors allows for a substantial reduction of weight and sizes of the parts compared to currently used military grade precious metal electrode (PME) capacitors. Insertion of BME capacitors in space applications requires a thorough analysis of their performance and reliability. In this work, six types of cases size 0603 BME capacitors from three vendors have been evaluated. Three types of multilayer ceramic capacitors (MLCCs) were designed for automotive industry and three types for general purposes. Leakage currents in the capacitors have been measured in a wide range of voltages and temperatures, and measurements of breakdown voltages (VBR) have been used to assess the proportion and severity of defects in the parts. The effect of soldering-related thermal shock stresses was evaluated by analysis of distributions of VBR for parts in 'as is' condition and after terminal solder dip testing at 350 C. Highly Accelerated Life Testing (HALT) at different temperatures was used to assess the activation energy of degradation of leakage currents and predict behavior of the parts at life test and normal operating conditions. To address issues related to rework and manual soldering, capacitors were soldered onto different substrates at different soldering conditions. The results show that contrary to a common assumption that large-size capacitors are mostly vulnerable to soldering stresses, cracking in small size capacitors does happen unless special measures are taken during assembly processes.

  16. Effects of Age and Size on Xylem Phenology in Two Conifers of Northwestern China

    PubMed Central

    Zeng, Qiao; Rossi, Sergio; Yang, Bao

    2018-01-01

    The climatic signals that directly affect the trees can be registered by xylem during its growth. If the timings and duration of xylem formation change, xylogenesis can occur under different environmental conditions and subsequently be subject to different climatic signals. An experimental design was applied in the field to disentangle the effects of age and size on xylem phenology, and it challenges the hypothesis that the timings and dynamics of xylem growth are size-dependent. Intra-annual dynamics of xylem formation were monitored weekly during the growing seasons 2013 and 2014 in Chinese pine (Pinus tabulaeformis) and Qilian juniper (Juniperus przewalskii) with different sizes and ages in a semi-arid region of northwestern China. Cell differentiation started 3 weeks earlier in 2013 and terminated 1 week later in 2014 in small-young pines than in big-old pines. However, differences in the timings of growth reactivation disappeared when comparing the junipers with different sizes but similar age. Overall, 77 days were required for xylem differentiation to take place, but timings were shorter for older trees, which also exhibited smaller cell production. Results from this study suggest that tree age does play an important role in timings and duration of growth. The effect of age should also be considered to perform reliable responses of trees to climate. PMID:29379517

  17. Green Chemistry at the present in Korea.

    PubMed

    Lee, Seung-Kyu; Park, Hyeon-Soo

    2015-01-01

    Despite the great contribution made by chemical substances to the development of modern civilization, their indiscriminate use has caused various kinds of damage to the global environment and human beings. Accordingly, the major developed countries and international society have tried to ensure the safe use of chemicals and a reduction in the use of hazardous chemicals through the establishment of the United Nations Environment Programme and various international agreements. In this reason, we tried to introduce about Green Chemistry progress at the present in worldwide and Korea. We checked and analyzed relative journals, reports using keyword as like Green Chemistry, alternative chemicals, eco-friendly etc. and major country's government homepage search. Green Chemistry theory, which argues for the reduction or removal of harmfulness in chemicals throughout their entire life-cycle, has been spreading, and major developed countries, such as the US and Denmark, have developed and operate programs to provide reliable chemical information to help replace hazardous chemicals. Korea has also been conducting studies as like eco-innovation project. Through this project the "Alternative Chemical Search program," has been developed, distributed, and operated since 2011 to provide reliable information to small and medium-sized businesses that have difficulties collecting information to ensure conformity to international regulations. The program provides information that includes the regulations of major countries and Korea, information on 340 alternative chemicals, 70 application cases, and 1:1 consulting. The Alternative Chemical Search program is expected to contribute to the establishment of response systems for regulation of Korean small and medium-sized businesses, and it also will be used to provide basic data for Korean hazardous chemical regulation, together with the Act on the Registration and Evaluation, etc. of Chemical Substances and the Chemical Control act, making it possible to establish an infrastructure for Green Chemistry in Korea and to increase national competitiveness.

  18. Low Power Consumption Lasers for Next Generation Miniature Optical Spectrometers for Major Constituent and Trace Gas Analysis

    NASA Technical Reports Server (NTRS)

    Forouhar, Siamak; Soibel, Alexander; Frez, Clifford; Qiu, Yueming; Chen, J.; Hosoda, T.; Kipshidze, G.; Shterengas, L.; Tsvid, G.; Belenky, G.; hide

    2010-01-01

    The air quality of any manned spacecraft needs to be continuously monitored in order to safeguard the health of the crew. Air quality monitoring grows in importance as mission duration increases. Due to the small size, low power draw, and performance reliability, semiconductor laser-based instruments are viable candidates for this purpose. The minimum instrument size requires lasers with emission wavelength coinciding with the absorption of the fundamental frequency of the target gases which are mostly in the 3.0-5.0 micrometers wavelength range. In this paper we report on our progress developing high wall plug efficiency type-I quantum-well GaSb-based diode lasers operating at room temperatures in the spectral region near 3.0-3.5 micrometers and quantum cascade (QC) lasers in the 4.0-5.0 micrometers range. These lasers will enable the development of miniature, low-power laser spectrometers for environmental monitoring of the spacecraft.

  19. Personality and symptom change in treatment-refractory inpatients: evaluation of the phase model of change using Rorschach,TAT, and DSM-IV Axis V.

    PubMed

    Fowler, J Christopher; Ackerman, Steven J; Speanburg, Stefanie; Bailey, Adrian; Blagys, Matthew; Conklin, Adam C

    2004-12-01

    In this study, we examined global treatment outcomes during 16 months of intensive, psychodynamic treatment for 77 inpatients suffering from treatment-refractory disorders. Hypotheses based on the phase model of treatment change (Howard, Lueger, Maling, & Martinovich, 1993; Howard, Moras, Brill, Martinovich, & Lutz, 1996) were supported in the study results. Diagnostic and Statistical Manual of Mental Disorders (4th ed.; American Psychiatric Association, 1994) Axis V scales assessing behavioral functioning demonstrated large and medium effect size change, whereas stable, enduring personality functioning assessed by psychoanalytic Rorschach scales and the Social Cognition and Object Relations Scale (Westen, 1995) for the Thematic Apperception Test (Murray, 1943) demonstrated small and medium effect size change. We also report assessment of reliable change index and clinical significance. The ecological validity of Rorschach measures is supported by significant validity coefficients (in the hypothesized directions) between implicit measures of personality functioning and behavioral ratings.

  20. Non-invasive brain stimulation to investigate language production in healthy speakers: A meta-analysis.

    PubMed

    Klaus, Jana; Schutter, Dennis J L G

    2018-06-01

    Non-invasive brain stimulation (NIBS) has become a common method to study the interrelations between the brain and language functioning. This meta-analysis examined the efficacy of transcranial magnetic stimulation (TMS) and direct current stimulation (tDCS) in the study of language production in healthy volunteers. Forty-five effect sizes from 30 studies which investigated the effects of NIBS on picture naming or verbal fluency in healthy participants were meta-analysed. Further sub-analyses investigated potential influences of stimulation type, control, target site, task, online vs. offline application, and current density of the target electrode. Random effects modelling showed a small, but reliable effect of NIBS on language production. Subsequent analyses indicated larger weighted mean effect sizes for TMS as compared to tDCS studies. No statistical differences for the other sub-analyses were observed. We conclude that NIBS is a useful method for neuroscientific studies on language production in healthy volunteers. Copyright © 2018 The Authors. Published by Elsevier Inc. All rights reserved.

  1. Evidence of a rolling motion of a microparticle on a silicon wafer in a liquid environment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schiwek, Simon; Stark, Robert W., E-mail: stark@csi.tu-darmstadt.de, E-mail: dietz@csi.tu-darmstadt.de; Dietz, Christian, E-mail: stark@csi.tu-darmstadt.de, E-mail: dietz@csi.tu-darmstadt.de

    2016-05-21

    The interaction of micro- and nanometer-sized particles with surfaces plays a crucial role when small-scale structures are built in a bottom-up approach or structured surfaces are cleaned in the semiconductor industry. For a reliable quantification of the interaction between individual particles and a specific surface, however, the motion type of the particle must be known. We developed an approach to unambiguously distinguish between sliding and rolling particles. To this end, fluorescent particles were partially bleached in a confocal laser scanning microscope to tailor an optical inhomogeneity, which allowed for the identification of the characteristic motion pattern. For the manipulation, themore » water flow generated by a fast moving cantilever-tip of an atomic force microscope enabled the contactless pushing of the particle. We thus experimentally evidenced a rolling motion of a micrometer-sized particle directly with a fluorescence microscope. A similar approach could help to discriminate between rolling and sliding particles in liquid flows of microfluidic systems.« less

  2. Evolving MEMS Resonator Designs for Fabrication

    NASA Technical Reports Server (NTRS)

    Hornby, Gregory S.; Kraus, William F.; Lohn, Jason D.

    2008-01-01

    Because of their small size and high reliability, microelectromechanical (MEMS) devices have the potential to revolution many areas of engineering. As with conventionally-sized engineering design, there is likely to be a demand for the automated design of MEMS devices. This paper describes our current status as we progress toward our ultimate goal of using an evolutionary algorithm and a generative representation to produce designs of a MEMS device and successfully demonstrate its transfer to an actual chip. To produce designs that are likely to transfer to reality, we present two ways to modify evaluation of designs. The first is to add location noise, differences between the actual dimensions of the design and the design blueprint, which is a technique we have used for our work in evolving antennas and robots. The second method is to add prestress to model the warping that occurs during the extreme heat of fabrication. In future we expect to fabricate and test some MEMS resonators that are evolved in this way.

  3. Skyrmion-skyrmion and skyrmion-edge repulsions in skyrmion-based racetrack memory

    NASA Astrophysics Data System (ADS)

    Zhang, Xichao; Zhao, G. P.; Fangohr, Hans; Liu, J. Ping; Xia, W. X.; Xia, J.; Morvan, F. J.

    2015-01-01

    Magnetic skyrmions are promising for building next-generation magnetic memories and spintronic devices due to their stability, small size and the extremely low currents needed to move them. In particular, skyrmion-based racetrack memory is attractive for information technology, where skyrmions are used to store information as data bits instead of traditional domain walls. Here we numerically demonstrate the impacts of skyrmion-skyrmion and skyrmion-edge repulsions on the feasibility of skyrmion-based racetrack memory. The reliable and practicable spacing between consecutive skyrmionic bits on the racetrack as well as the ability to adjust it are investigated. Clogging of skyrmionic bits is found at the end of the racetrack, leading to the reduction of skyrmion size. Further, we demonstrate an effective and simple method to avoid the clogging of skyrmionic bits, which ensures the elimination of skyrmionic bits beyond the reading element. Our results give guidance for the design and development of future skyrmion-based racetrack memory.

  4. Low power consumption lasers for next generation miniature optical spectrometers for trace gas analysis

    NASA Astrophysics Data System (ADS)

    Forouhar, S.; Frez, C.; Franz, K. J.; Ksendzov, A.; Qiu, Y.; Soibel, K. A.; Chen, J.; Hosoda, T.; Kipshidze, G.; Shterengas, L.; Belenky, G.

    2011-01-01

    The air quality of any manned spacecraft needs to be continuously monitored in order to safeguard the health of the crew. Air quality monitoring grows in importance as mission duration increases. Due to the small size, low power draw, and performance reliability, semiconductor laser-based instruments are viable candidates for this purpose. Achieving a minimum instrument size requires lasers with emission wavelength coinciding with the absorption of the fundamental absorption lines of the target gases, which are mostly in the 3.0-5.0 μm wavelength range. In this paper we report on our progress developing high wall plug efficiency type-I quantum-well GaSb-based diode lasers operating at room temperatures in the spectral region near 3.0-3.5 μm and quantum cascade (QC) lasers in the 4.0-5.0 μm range. These lasers will enable the development of miniature, low-power laser spectrometers for environmental monitoring of the spacecraft.

  5. Design of nodes for embedded and ultra low-power wireless sensor networks

    NASA Astrophysics Data System (ADS)

    Xu, Jun; You, Bo; Cui, Juan; Ma, Jing; Li, Xin

    2008-10-01

    Sensor network integrates sensor technology, MEMS (Micro-Electro-Mechanical system) technology, embedded computing, wireless communication technology and distributed information management technology. It is of great value to use it where human is quite difficult to reach. Power consumption and size are the most important consideration when nodes are designed for distributed WSN (wireless sensor networks). Consequently, it is of great importance to decrease the size of a node, reduce its power consumption and extend its life in network. WSN nodes have been designed using JN5121-Z01-M01 module produced by jennic company and IEEE 802.15.4/ZigBee technology. Its new features include support for CPU sleep modes and a long-term ultra low power sleep mode for the entire node. In low power configuration the node resembles existing small low power nodes. An embedded temperature sensor node has been developed to verify and explore our architecture. The experiment results indicate that the WSN has the characteristic of high reliability, good stability and ultra low power consumption.

  6. A Review and Meta-Analysis of Age-Based Stereotype Threat: Negative Stereotypes, Not Facts, Do the Damage

    PubMed Central

    2015-01-01

    Stereotype threat effects arise when an individual feels at risk of confirming a negative stereotype about their group and consequently underperforms on stereotype relevant tasks (Steele, 2010). Among older people, underperformance across cognitive and physical tasks is hypothesized to result from age-based stereotype threat (ABST) because of negative age-stereotypes regarding older adults’ competence. The present review and meta-analyses examine 22 published and 10 unpublished articles, including 82 effect sizes (N = 3882) investigating ABST on older people’s (Mage = 69.5) performance. The analysis revealed a significant small-to-medium effect of ABST (d = .28) and important moderators of the effect size. Specifically, older adults are more vulnerable to ABST when (a) stereotype-based rather than fact-based manipulations are used (d = .52); (b) when performance is tested using cognitive measures (d = .36); and (c) occurs reliably when the dependent variable is measured proximally to the manipulation. The review raises important theoretical and methodological issues, and areas for future research. PMID:25621742

  7. Banded karyotype of the Konya wild sheep (Ovis orientalis anatolica Valenciennes, 1856) from Turkey

    PubMed Central

    Arslan, Atilla; Zima, Jan

    2011-01-01

    Abstract Thekaryotype, C-banding, and nucleoar organizer regions (NORs) of eight specimens ofKonya wild sheepfrom Turkey were examined. The complement included six large metacentric autosomes, 46 acrocentric autosomes of decreasing size, a medium-sized acrocentric X chromosome, and a small bi-armed Y chromosome (the diploid chromosome number 2n=54, the number of autosomal arms NFa=58, the number of chromosome arms NF=61). G-banding allowed reliable identification of all the chromosome pairs and the pairing of homologous elements. All the autosomes possessed distinct centromeric or pericentromeric C-positive bands. The X chromosome had a pericentromeric C-positive band, and the Y chromosome was entirely C-heterochromatic. The NORs were located in the terminal regions of the long arms of three metacentric and two acrocentric autosomes. The karyotype of the Konya wild sheep and its banding patterns are quite similar to chromosome complement reported in domestic sheep and European mouflon. PMID:24260621

  8. Physical response of gold nanoparticles to single self-ion bombardment

    DOE PAGES

    Bufford, Daniel C.; Hattar, Khalid

    2014-09-23

    The reliability of nanomaterials depends on maintaining their specific sizes and structures. However, the stability of many nanomaterials in radiation environments remains uncertain due to the lack of a fully developed fundamental understanding of the radiation response on the nanoscale. To provide an insight into the dynamic aspects of single ion effects in nanomaterials, gold nanoparticles (NPs) with nominal diameters of 5, 20, and 60 nm were subjected to self-ion irradiation at energies of 46 keV, 2.8 MeV, and 10 MeV in situ inside of a transmission electron microscope. Ion interactions created a variety of far-from-equilibrium structures including small (~1more » nm) sputtered nanoclusters from the parent NPs of all sizes. Single ions created surface bumps and elongated nanofilaments in the 60 nm NPs. As a result, similar shape changes were observed in the 20 nm nanoparticles, while the 5 nm nanoparticles were transiently melted or explosively broken apart.« less

  9. A practical and theoretical definition of very small field size for radiotherapy output factor measurements

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Charles, P. H., E-mail: p.charles@qut.edu.au; Crowe, S. B.; Langton, C. M.

    Purpose: This work introduces the concept of very small field size. Output factor (OPF) measurements at these field sizes require extremely careful experimental methodology including the measurement of dosimetric field size at the same time as each OPF measurement. Two quantifiable scientific definitions of the threshold of very small field size are presented. Methods: A practical definition was established by quantifying the effect that a 1 mm error in field size or detector position had on OPFs and setting acceptable uncertainties on OPF at 1%. Alternatively, for a theoretical definition of very small field size, the OPFs were separated intomore » additional factors to investigate the specific effects of lateral electronic disequilibrium, photon scatter in the phantom, and source occlusion. The dominant effect was established and formed the basis of a theoretical definition of very small fields. Each factor was obtained using Monte Carlo simulations of a Varian iX linear accelerator for various square field sizes of side length from 4 to 100 mm, using a nominal photon energy of 6 MV. Results: According to the practical definition established in this project, field sizes ≤15 mm were considered to be very small for 6 MV beams for maximal field size uncertainties of 1 mm. If the acceptable uncertainty in the OPF was increased from 1.0% to 2.0%, or field size uncertainties are 0.5 mm, field sizes ≤12 mm were considered to be very small. Lateral electronic disequilibrium in the phantom was the dominant cause of change in OPF at very small field sizes. Thus the theoretical definition of very small field size coincided to the field size at which lateral electronic disequilibrium clearly caused a greater change in OPF than any other effects. This was found to occur at field sizes ≤12 mm. Source occlusion also caused a large change in OPF for field sizes ≤8 mm. Based on the results of this study, field sizes ≤12 mm were considered to be theoretically very small for 6 MV beams. Conclusions: Extremely careful experimental methodology including the measurement of dosimetric field size at the same time as output factor measurement for each field size setting and also very precise detector alignment is required at field sizes at least ≤12 mm and more conservatively≤15 mm for 6 MV beams. These recommendations should be applied in addition to all the usual considerations for small field dosimetry, including careful detector selection.« less

  10. A practical and theoretical definition of very small field size for radiotherapy output factor measurements.

    PubMed

    Charles, P H; Cranmer-Sargison, G; Thwaites, D I; Crowe, S B; Kairn, T; Knight, R T; Kenny, J; Langton, C M; Trapp, J V

    2014-04-01

    This work introduces the concept of very small field size. Output factor (OPF) measurements at these field sizes require extremely careful experimental methodology including the measurement of dosimetric field size at the same time as each OPF measurement. Two quantifiable scientific definitions of the threshold of very small field size are presented. A practical definition was established by quantifying the effect that a 1 mm error in field size or detector position had on OPFs and setting acceptable uncertainties on OPF at 1%. Alternatively, for a theoretical definition of very small field size, the OPFs were separated into additional factors to investigate the specific effects of lateral electronic disequilibrium, photon scatter in the phantom, and source occlusion. The dominant effect was established and formed the basis of a theoretical definition of very small fields. Each factor was obtained using Monte Carlo simulations of a Varian iX linear accelerator for various square field sizes of side length from 4 to 100 mm, using a nominal photon energy of 6 MV. According to the practical definition established in this project, field sizes ≤ 15 mm were considered to be very small for 6 MV beams for maximal field size uncertainties of 1 mm. If the acceptable uncertainty in the OPF was increased from 1.0% to 2.0%, or field size uncertainties are 0.5 mm, field sizes ≤ 12 mm were considered to be very small. Lateral electronic disequilibrium in the phantom was the dominant cause of change in OPF at very small field sizes. Thus the theoretical definition of very small field size coincided to the field size at which lateral electronic disequilibrium clearly caused a greater change in OPF than any other effects. This was found to occur at field sizes ≤ 12 mm. Source occlusion also caused a large change in OPF for field sizes ≤ 8 mm. Based on the results of this study, field sizes ≤ 12 mm were considered to be theoretically very small for 6 MV beams. Extremely careful experimental methodology including the measurement of dosimetric field size at the same time as output factor measurement for each field size setting and also very precise detector alignment is required at field sizes at least ≤ 12 mm and more conservatively ≤ 15 mm for 6 MV beams. These recommendations should be applied in addition to all the usual considerations for small field dosimetry, including careful detector selection. © 2014 American Association of Physicists in Medicine.

  11. 18 CFR 292.308 - Standards for operating reliability.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... reliability. 292.308 Section 292.308 Conservation of Power and Water Resources FEDERAL ENERGY REGULATORY... SMALL POWER PRODUCTION AND COGENERATION Arrangements Between Electric Utilities and Qualifying... may establish reasonable standards to ensure system safety and reliability of interconnected...

  12. Size effects and realiability of barium strontium titanate thin films

    NASA Astrophysics Data System (ADS)

    Parker, Charles Bernard

    Thin films of (Ba,Sr)TiO3 (BST) deposited by Liquid Source MOCVD were investigated. BST is a candidate dielectric for future-generation DRAM and as a tunable dielectric. Two areas of both scientific and commercial interest were investigated. The first area is the effect of decreasing dimension on ferroelectric properties. Several theories of size effects in ferroelectrics were evaluated. The dielectric response of a set of BST films of thicknesses from 15 to 580 nm was measured from 85 to 580 K. These films were extensively characterized and the boundary conditions that often influence size effects measurements were considered, including strain, finite screening length in the electrode, depolarization fields in the ferroelectric, atmospheric effects, control of stochiometry, and others. The data set was compared to the theoretical predictions and it was determined that Finite Size Scaling provided the best fit to the data. Using this theory, the predicted dielectric response was compared to the requirements of future generations of DRAM and was found to be sufficient, if film strain can be controlled. The second area is reliability. The types of lifetime-limiting electrical failure observed in BST are resistance degradation, time dependant dielectric breakdown (tddb), and noisy breakdown. Previous work on BST reliability has largely focused on resistance degradation at high temperature. This condition is only a small subset of experimental space. This work extends the understanding of BST failure into the low temperature regime and evaluates the effects of both DC and AC stress. It was found that tddb is the dominant failure mode at low temperature and resistance degradation is the dominant failure modes at high temperature. Synthesizing this work with previous work on resistance degradation allowed a failure framework to be developed. Rigorous extrapolation of resistance degradation and tddb lifetimes was compared to the requirements of future generations of DRAM and was found that while resistance degradation will not limit device lifetimes, tddb will. Refinement of BST processing will be necessary to reduce the defect causing tddb failure.

  13. Reliability of the Q Force; a mobile instrument for measuring isometric quadriceps muscle strength.

    PubMed

    Douma, K W; Regterschot, G R H; Krijnen, W P; Slager, G E C; van der Schans, C P; Zijlstra, W

    2016-01-01

    The ability to generate muscle strength is a pre-requisite for all human movement. Decreased quadriceps muscle strength is frequently observed in older adults and is associated with a decreased performance and activity limitations. To quantify the quadriceps muscle strength and to monitor changes over time, instruments and procedures with a sufficient reliability are needed. The Q Force is an innovative mobile muscle strength measurement instrument suitable to measure in various degrees of extension. Measurements between 110 and 130° extension present the highest values and the most significant increase after training. The objective of this study is to determine the test-retest reliability of muscle strength measurements by the Q Force in older adults in 110° extension. Forty-one healthy older adults, 13 males and 28 females were included in the study. Mean (SD) age was 81.9 (4.89) years. Isometric muscle strength of the Quadriceps muscle was assessed with the Q Force at 110° of knee extension. Participants were measured at two sessions with a three to eight day interval between sessions. To determine relative reliability, the intraclass correlation coefficient (ICC) was calculated. To determine absolute reliability, Bland and Altman Limits of Agreement (LOA) were calculated and t-tests were performed. Relative reliability of the Q Force is good to excellent as all ICC coefficients are higher than 0.75. Generally a large 95 % LOA, reflecting only moderate absolute reliability, is found as exemplified for the peak torque left leg of -18.6 N to 33.8 N and the right leg of -9.2 N to 26.4 N was between 15.7 and 23.6 Newton representing 25.2 % to 39.9 % of the size of the mean. Small systematic differences in mean were found between measurement session 1 and 2. The present study shows that the Q Force has excellent relative test-retest reliability, but limited absolute test-retest reliability. Since the Q Force is relatively cheap and mobile it is suitable for application in various clinical settings, however, its capability to detect changes in muscle force over time is limited but comparable to existing instruments.

  14. "Reliability of the Norwegian version of the short physical performance battery in older people with and without dementia".

    PubMed

    Olsen, Cecilie Fromholt; Bergland, Astrid

    2017-06-09

    The purpose of the study was to establish the test-retest reliability of the Norwegian version of the Short Physical Performance Battery (SPPB). This was a cross- sectional reliability study. A convenience sample of 61 older adults with a mean age of 88.4(8.1) was tested by two different physiotherapists at two time points. The mean time interval between tests was 2.5 days. The Intraclass Correlation Coefficient model 3.1 (ICC, 3.1) with 95% confidence intervals as well as the weighted Kappa (K) were used as measures of relative reliability. The Standard Error of Measurement (SEM) and Minimal Detectable Change (MDC) were used to measure absolute reliability. The results were also analyzed for a subgroup of 24 older people with dementia. The ICC reflected high relative reliability for the SPPB summary score and the 4 m walk test (4mwt), both for the total sample (ICC = 0.92, and 0.91 respectively)) and for the subgroup with dementia (ICC = 0.84 and 0.90 respectively). Furthermore, weighted Ks for the SPPB subscales were 0.64 for the chair stand, 0.80 for gait and 0.52 for balance for the total sample and almost identical for the subgroup with dementia. MDC-values at the 95% confidence intervals (MDC95) were calculated at 0.8 for the total score of SPPB and 0.39 m/s for the 4mwt in the total sample. For the subgroup with dementia MDC95 was 1.88 for the total score of SPPB and 0.28 m/s for 4mwt. The SPPB total score and the timed walking test showed overall high relative and absolute reliability for the total sample indicating that the Norwegian version of the SPPB is reliable when used by trained physiotherapists with older people. The reliability of the Norwegian SPPB in older people with dementia seems high, but due to a small sample size this needs further investigation.

  15. The demographic consequences of growing older and bigger in oyster populations.

    PubMed

    Moore, Jacob L; Lipcius, Romuald N; Puckett, Brandon; Schreiber, Sebastian J

    2016-10-01

    Structured population models, particularly size- or age-structured, have a long history of informing conservation and natural resource management. While size is often easier to measure than age and is the focus of many management strategies, age-structure can have important effects on population dynamics that are not captured in size-only models. However, relatively few studies have included the simultaneous effects of both age- and size-structure. To better understand how population structure, particularly that of age and size, impacts restoration and management decisions, we developed and compared a size-structured integral projection model (IPM) and an age- and size-structured IPM, using a population of Crassostrea gigas oysters in the northeastern Pacific Ocean. We analyzed sensitivity of model results across values of local retention that give populations decreasing in size to populations increasing in size. We found that age- and size-structured models yielded the best fit to the demographic data and provided more reliable results about long-term demography. Elasticity analysis showed that population growth rate was most sensitive to changes in the survival of both large (>175 mm shell length) and small (<75 mm shell length) oysters, indicating that a maximum size limit, in addition to a minimum size limit, could be an effective strategy for maintaining a sustainable population. In contrast, the purely size-structured model did not detect the importance of large individuals. Finally, patterns in stable age and stable size distributions differed between populations decreasing in size due to limited local retention and populations increasing in size due to high local retention. These patterns can be used to determine population status and restoration success. The methodology described here provides general insight into the necessity of including both age- and size-structure into modeling frameworks when using population models to inform restoration and management decisions. © 2016 by the Ecological Society of America.

  16. An improved camera trap for amphibians, reptiles, small mammals, and large invertebrates

    PubMed Central

    2017-01-01

    Camera traps are valuable sampling tools commonly used to inventory and monitor wildlife communities but are challenged to reliably sample small animals. We introduce a novel active camera trap system enabling the reliable and efficient use of wildlife cameras for sampling small animals, particularly reptiles, amphibians, small mammals and large invertebrates. It surpasses the detection ability of commonly used passive infrared (PIR) cameras for this application and eliminates problems such as high rates of false triggers and high variability in detection rates among cameras and study locations. Our system, which employs a HALT trigger, is capable of coupling to digital PIR cameras and is designed for detecting small animals traversing small tunnels, narrow trails, small clearings and along walls or drift fencing. PMID:28981533

  17. 77 FR 30265 - Submission for OMB Review; Small Business Size Representation

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-05-22

    ... Information Collection 9000- 0163, Small Business Size Representation, by any of the following methods... Business Size Representation AGENCY: Department of Defense (DOD), General Services Administration (GSA... of a previously approved information collection requirement regarding small business size...

  18. A TEOM (tm) particulate monitor for comet dust, near Earth space, and planetary atmospheres

    NASA Astrophysics Data System (ADS)

    1988-04-01

    Scientific missions to comets, near earth space, and planetary atmospheres require particulate and mass accumulation instrumentation for both scientific and navigation purposes. The Rupprecht & Patashnick tapered element oscillating microbalance can accurately measure both mass flux and mass distribution of particulates over a wide range of particle sizes and loadings. Individual particles of milligram size down to a few picograms can be resolved and counted, and the accumulation of smaller particles or molecular deposition can be accurately measured using the sensors perfected and toughened under this contract. No other sensor has the dynamic range or sensitivity attained by these picogram direct mass measurement sensors. The purpose of this contract was to develop and implement reliable and repeatable manufacturing methods; build and test prototype sensors; and outline a quality control program. A dust 'thrower' was to be designed and built, and used to verify performance. Characterization and improvement of the optical motion detection system and drive feedback circuitry was to be undertaken, with emphasis on reliability, low noise, and low power consumption. All the goals of the contract were met or exceeded. An automated glass puller was built and used to make repeatable tapered elements. Materials and assembly methods were standardized, and controllers and calibrated fixtures were developed and used in all phases of preparing, coating and assembling the sensors. Quality control and reliability resulted from the use of calibrated manufacturing equipment with measurable working parameters. Thermal and vibration testing of completed prototypes showed low temperature sensitivity and high vibration tolerance. An electrostatic dust thrower was used in vacuum to throw particles from 2 x 106 g to 7 x 10-12 g in size. Using long averaging times, particles as small as 0.7 to 4 x 1011 g were weighted to resolutions in the 5 to 9 x 10-13 g range. The drive circuit and optics systems were developed beyond what was anticipated in the contract, and are now virtually flight prototypes. There is already commercial interest in the developed capability of measuring picogram mass losses and gains. One area is contamination and outgassing research, both measuring picogram losses from samples and collecting products of outgassing.

  19. Velopharyngeal insufficiency: diagnosis and management

    PubMed Central

    Shprintzen, Robert J.; Marrinan, Eileen

    2009-01-01

    Purpose of Review Journal articles relevant to the diagnosis and treatment of velopharyngeal insufficiency (VPI) were reviewed. All articles ascertained by PubMed search were included. Recent Findings Articles reported on the application of magnetic resonance scanning, reliability tests of the International Working Group diagnostic protocol, the use of nasometry, and techniques designed to assess the function of the velopharyngeal mechanism. Treatment papers focused on outcomes in small samples of cases and complication rates from pharyngeal flap. One paper discussed ineffective speech therapy procedures. Summary There were relatively few papers this past year. Those that were published were hindered by small and heterogeneous sample sizes, and occasionally by inappropriate methods for assessing outcomes. None of the findings will have a major impact on the current state-of-the-art for diagnosis of VPI. The speech therapy paper has a very important message that should be taken to heart by all clinicians involved in the management of children with clefts and craniofacial disorders. PMID:19448542

  20. PV system field experience and reliability

    NASA Astrophysics Data System (ADS)

    Durand, Steven; Rosenthal, Andrew; Thomas, Mike

    1997-02-01

    Hybrid power systems consisting of battery inverters coupled with diesel, propane, or gasoline engine-driven electrical generators, and photovoltaic arrays are being used in many remote locations. The potential cost advantages of hybrid systems over simple engine-driven generator systems are causing hybrid systems to be considered for numerous applications including single-family residential, communications, and village power. This paper discusses the various design constraints of such systems and presents one technique for reducing hybrid system losses. The Southwest Technology Development Institute under contract to the National Renewable Energy Laboratory and Sandia National Laboratories has been installing data acquisition systems (DAS) on a number of small and large hybrid PV systems. These systems range from small residential systems (1 kW PV - 7 kW generator), to medium sized systems (10 kW PV - 20 kW generator), to larger systems (100 kW PV - 200 kW generator). Even larger systems are being installed with hundreds of kilowatts of PV modules, multiple wind machines, and larger diesel generators.

  1. High sensitivity detection and sorting of infectious human immunodeficiency virus (HIV-1) particles by flow virometry

    PubMed Central

    Bonar, Micha M.; Tilton, John C.

    2017-01-01

    Detection of viruses by flow cytometry is complicated by their small size. Here, we characterized the ability of a standard (FACSAria II) and a sub-micron flow cytometer (A50 Micro) to resolve HIV-1 viruses. The A50 was superior at resolving small particles but did not reliably distinguish HIV-1, extracellular vesicles, and laser noise by light scatter properties alone. However, single fluorescent HIV-1 particles could readily be detected by both cytometers. Fluorescent particles were sorted and retained infectivity, permitting further exploration of the functional consequences of HIV-1 heterogeneity. Finally, flow cytometry had a limit of detection of 80 viruses/ml, nearly equal to PCR assays. These studies demonstrate the power of flow cytometry to detect and sort viral particles and provide a critical toolkit to validate methods to label wild-type HIV-1; quantitatively assess integrity and aggregation of viruses and virus-based therapeutics; and efficiently screen drugs inhibiting viral assembly and release. PMID:28235684

  2. High sensitivity detection and sorting of infectious human immunodeficiency virus (HIV-1) particles by flow virometry.

    PubMed

    Bonar, Michał M; Tilton, John C

    2017-05-01

    Detection of viruses by flow cytometry is complicated by their small size. Here, we characterized the ability of a standard (FACSAria II) and a sub-micron flow cytometer (A50 Micro) to resolve HIV-1 viruses. The A50 was superior at resolving small particles but did not reliably distinguish HIV-1, extracellular vesicles, and laser noise by light scatter properties alone. However, single fluorescent HIV-1 particles could readily be detected by both cytometers. Fluorescent particles were sorted and retained infectivity, permitting further exploration of the functional consequences of HIV-1 heterogeneity. Finally, flow cytometry had a limit of detection of 80 viruses/ml, nearly equal to PCR assays. These studies demonstrate the power of flow cytometry to detect and sort viral particles and provide a critical toolkit to validate methods to label wild-type HIV-1; quantitatively assess integrity and aggregation of viruses and virus-based therapeutics; and efficiently screen drugs inhibiting viral assembly and release. Copyright © 2017 Elsevier Inc. All rights reserved.

  3. Network Reliability: The effect of local network structure on diffusive processes

    PubMed Central

    Youssef, Mina; Khorramzadeh, Yasamin; Eubank, Stephen

    2014-01-01

    This paper re-introduces the network reliability polynomial – introduced by Moore and Shannon in 1956 – for studying the effect of network structure on the spread of diseases. We exhibit a representation of the polynomial that is well-suited for estimation by distributed simulation. We describe a collection of graphs derived from Erdős-Rényi and scale-free-like random graphs in which we have manipulated assortativity-by-degree and the number of triangles. We evaluate the network reliability for all these graphs under a reliability rule that is related to the expected size of a connected component. Through these extensive simulations, we show that for positively or neutrally assortative graphs, swapping edges to increase the number of triangles does not increase the network reliability. Also, positively assortative graphs are more reliable than neutral or disassortative graphs with the same number of edges. Moreover, we show the combined effect of both assortativity-by-degree and the presence of triangles on the critical point and the size of the smallest subgraph that is reliable. PMID:24329321

  4. Small-Animal Molecular Imaging for Preclinical Cancer Research: .μPET and μ.SPECT.

    PubMed

    Cuccurullo, Vincenzo; Di Stasio, Giuseppe D; Schillirò, Maria L; Mansi, Luigi

    2016-01-01

    Due to different sizes of humans and rodents, the performance of clinical imaging devices is not enough for a scientifically reliable evaluation in mice and rats; therefore dedicated small-animal systems with a much higher sensitivity and spatial resolution, compared to the ones used in humans, are required. Smallanimal imaging represents a cutting-edge research method able to approach an enormous variety of pathologies in which animal models of disease may be used to elucidate the mechanisms underlying the human condition and/or to allow a translational pharmacological (or other) evaluation of therapeutic tools. Molecular imaging, avoiding animal sacrifice, permits repetitive (i.e. longitudinal) studies on the same animal which becomes its own control. In this way also the over time evaluation of disease progression or of the treatment response is enabled. Many different rodent models have been applied to study almost all kind of human pathologies or to experiment a wide series of drugs and/or other therapeutic instruments. In particular, relevant information has been achieved in oncology by in vivo neoplastic phenotypes, obtained through procedures such as subcutaneous tumor grafts, surgical transplantation of solid tumor, orthotopic injection of tumor cells into specific organs/sites of interest, genetic modification of animals to promote tumor-genesis; in this way traditional or innovative treatments, also including gene therapy, of animals with a cancer induced by a known carcinogen may be experimented. Each model has its own disadvantage but, comparing different studies, it is possible to achieve a panoramic and therefore substantially reliable view on the specific subject. Small-animal molecular imaging has become an invaluable component of modern biomedical research that will gain probably an increasingly important role in the next few years.

  5. A low-cost multichannel wireless neural stimulation system for freely roaming animals.

    PubMed

    Alam, Monzurul; Chen, Xi; Fernandez, Eduardo

    2013-12-01

    Electrical stimulation of nerve tissue and recording of neural activity are the basis of many therapies and neural prostheses. Conventional stimulation systems have a number of practical limitations, especially in experiments involving freely roaming subjects. Our main objective was to develop a modular, versatile and inexpensive multichannel wireless system able to overcome some of these constraints. We have designed and implemented a new multichannel wireless neural stimulator based on commercial components. The system is small (2 cm × 4 cm × 0.5 cm) and light in weight (9 g) which allows it to be easily carried in a small backpack. To test and validate the performance and reliability of the whole system we conducted several bench tests and in vivo experiments. The performance and accuracy of the stimulator were comparable to commercial threaded systems. Stimulation sequences can be constructed on-the-fly with 251 selectable current levels (from 0 to 250 µA) with 1 µA step resolution. The pulse widths and intervals can be as long as 65 ms in 2 µs time resolution. The system covers approximately 10 m of transmission range in a regular laboratory environment and 100 m in free space (line of sight). Furthermore it provides great flexibility for experiments since it allows full control of the stimulator and the stimulation parameters in real time. When there is no stimulation, the device automatically goes into low-power sleep mode to preserve battery power. We introduce the design of a powerful multichannel wireless stimulator assembled from commercial components. Key features of the system are their reliability, robustness and small size. The system has a flexible design that can be modified straightforwardly to tailor it to any specific experimental need. Furthermore it can be effortlessly adapted for use with any kind of multielectrode arrays.

  6. 40 CFR 141.81 - Applicability of corrosion control treatment steps to small, medium-size and large water systems.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... treatment steps to small, medium-size and large water systems. 141.81 Section 141.81 Protection of... to small, medium-size and large water systems. (a) Systems shall complete the applicable corrosion...) or (b)(3) of this section. (2) A small system (serving ≤3300 persons) and a medium-size system...

  7. 40 CFR 141.81 - Applicability of corrosion control treatment steps to small, medium-size and large water systems.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... treatment steps to small, medium-size and large water systems. 141.81 Section 141.81 Protection of... to small, medium-size and large water systems. (a) Systems shall complete the applicable corrosion...) or (b)(3) of this section. (2) A small system (serving ≤3300 persons) and a medium-size system...

  8. 40 CFR 141.81 - Applicability of corrosion control treatment steps to small, medium-size and large water systems.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... treatment steps to small, medium-size and large water systems. 141.81 Section 141.81 Protection of... to small, medium-size and large water systems. (a) Systems shall complete the applicable corrosion...) or (b)(3) of this section. (2) A small system (serving ≤3300 persons) and a medium-size system...

  9. 40 CFR 141.81 - Applicability of corrosion control treatment steps to small, medium-size and large water systems.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... treatment steps to small, medium-size and large water systems. 141.81 Section 141.81 Protection of... to small, medium-size and large water systems. (a) Systems shall complete the applicable corrosion...) or (b)(3) of this section. (2) A small system (serving ≤3300 persons) and a medium-size system...

  10. Spatial and temporal variation of body size among early Homo.

    PubMed

    Will, Manuel; Stock, Jay T

    2015-05-01

    The estimation of body size among the earliest members of the genus Homo (2.4-1.5Myr [millions of years ago]) is central to interpretations of their biology. It is widely accepted that Homo ergaster possessed increased body size compared with Homo habilis and Homo rudolfensis, and that this may have been a factor involved with the dispersal of Homo out of Africa. The study of taxonomic differences in body size, however, is problematic. Postcranial remains are rarely associated with craniodental fossils, and taxonomic attributions frequently rest upon the size of skeletal elements. Previous body size estimates have been based upon well-preserved specimens with a more reliable species assessment. Since these samples are small (n < 5) and disparate in space and time, little is known about geographical and chronological variation in body size within early Homo. We investigate temporal and spatial variation in body size among fossils of early Homo using a 'taxon-free' approach, considering evidence for size variation from isolated and fragmentary postcranial remains (n = 39). To render the size of disparate fossil elements comparable, we derived new regression equations for common parameters of body size from a globally representative sample of hunter-gatherers and applied them to available postcranial measurements from the fossils. The results demonstrate chronological and spatial variation but no simple temporal or geographical trends for the evolution of body size among early Homo. Pronounced body size increases within Africa take place only after hominin populations were established at Dmanisi, suggesting that migrations into Eurasia were not contingent on larger body sizes. The primary evidence for these marked changes among early Homo is based upon material from Koobi Fora after 1.7Myr, indicating regional size variation. The significant body size differences between specimens from Koobi Fora and Olduvai support the cranial evidence for at least two co-existing morphotypes in the Early Pleistocene of eastern Africa. Copyright © 2015 Elsevier Ltd. All rights reserved.

  11. Geolocators on Golden-winged Warblers do not affect migratory ecology

    USGS Publications Warehouse

    Peterson, Sean M.; Streby, Henry M.; Kramer, Gunnar R.; Lehman, Justin A.; Buehler, David A.; Andersen, David E.

    2015-01-01

    The use of light-level geolocators is increasingly common for connecting breeding and nonbreeding sites and identifying migration routes in birds. Until recently, the mass and size of geolocators precluded their use on songbird species weighing <12 g. Reducing the mass of geolocators, such as by shortening or eliminating the light stalk, may make their deployment on small birds feasible, but may also inhibit their ability to receive light reliably, because small geolocators can be shaded by feathers. Here we report geolocator effects on migratory ecology of Golden-winged Warblers (Vermivora chrysoptera) in Minnesota and Tennessee. We also evaluated whether stalk length influenced precision of location data for birds on the breeding grounds. At 8–10 g, Golden-winged Warblers are the smallest birds to be outfitted with geolocators to date. We found no differences in return rates, inter-annual territory fidelity, or body mass between geolocator-marked individuals and a control group of color-banded individuals. We observed no difference in return rates or variation in estimated breeding locations between birds marked with stalked geolocators and those with stalkless geolocators. Our results suggest that some small songbirds can be safely marked with geolocators. Light stalks appear to be unnecessary for Golden-winged Warblers; the added mass and drag of stalks can probably be eliminated on other small songbirds.

  12. Paleoenvironmental reconstruction of the early Neolithic to middle Bronze Age Peña Larga rock shelter (Álava, Spain) from the small mammal record

    NASA Astrophysics Data System (ADS)

    Rofes, Juan; Zuluaga, Mari Cruz; Murelaga, Xabier; Fernández-Eraso, Javier; Bailon, Salvador; Iriarte, María José; Ortega, Luis Ángel; Alonso-Olazabal, Ainhoa

    2013-03-01

    The Peña Larga site, a rock shelter on the southern slopes of the Cantabrian cordillera (north Spain), is an archeological deposit covering nearly 4000 years, from the early Neolithic to the middle Bronze Age (Atlantic/Subboreal chronozones). It was used both as a household and as a stable, with a hiatus in the Chalcolithic when it was used as a collective sepulcher. Nearly twenty-eight thousand small vertebrate elements were recovered from its seven stratigraphic units, of which 2553 items were identified to the genus and/or species levels. The assemblage is composed of mammals, birds, reptiles, and amphibians. Of these, small mammals were used for paleoenvironmental reconstruction since they are very sensitive to climatic conditions, the sample sizes are large, and their preservation is good. Their distributions over time, measured in terms of relative abundance, serve as reliable proxies of habitat and climate change. The reconstruction of Peña Larga's past environments based on small mammals roughly coincides with the pollen and the amphibian/reptile records on the local scale, and with that of an ice core from Central Greenland on the global scale. This makes it a valuable tool for comparative purposes both in the regional and continental scales.

  13. 77 FR 13329 - Information Collection; Small Business Size Representation

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-03-06

    ... Collection 9000- 0163, Small Business Size Representation, by any of the following methods: Regulations.gov... ADMINISTRATION [OMB Control No. 9000-0163; Docket 2011-0076; Sequence 6] Information Collection; Small Business... previously approved information collection requirement regarding small business size representation. DATES...

  14. Very Large Scale Optimization

    NASA Technical Reports Server (NTRS)

    Vanderplaats, Garrett; Townsend, James C. (Technical Monitor)

    2002-01-01

    The purpose of this research under the NASA Small Business Innovative Research program was to develop algorithms and associated software to solve very large nonlinear, constrained optimization tasks. Key issues included efficiency, reliability, memory, and gradient calculation requirements. This report describes the general optimization problem, ten candidate methods, and detailed evaluations of four candidates. The algorithm chosen for final development is a modern recreation of a 1960s external penalty function method that uses very limited computer memory and computational time. Although of lower efficiency, the new method can solve problems orders of magnitude larger than current methods. The resulting BIGDOT software has been demonstrated on problems with 50,000 variables and about 50,000 active constraints. For unconstrained optimization, it has solved a problem in excess of 135,000 variables. The method includes a technique for solving discrete variable problems that finds a "good" design, although a theoretical optimum cannot be guaranteed. It is very scalable in that the number of function and gradient evaluations does not change significantly with increased problem size. Test cases are provided to demonstrate the efficiency and reliability of the methods and software.

  15. Long-term Blood Pressure Measurement in Freely Moving Mice Using Telemetry.

    PubMed

    Alam, Mohammad Afaque; Parks, Cory; Mancarella, Salvatore

    2016-05-17

    During the development of new vasoactive agents, arterial blood pressure monitoring is crucial for evaluating the efficacy of the new proposed drugs. Indeed, research focusing on the discovery of new potential therapeutic targets using genetically altered mice requires a reliable, long-term assessment of the systemic arterial pressure variation. Currently, the gold standard for obtaining long-term measurements of blood pressure in ambulatory mice uses implantable radio-transmitters, which require artery cannulation. This technique eliminates the need for tethering, restraining, or anesthetizing the animals which introduce stress and artifacts during data sampling. However, arterial blood pressure monitoring in mice via catheterization can be rather challenging due to the small size of the arteries. Here we present a step-by-step guide to illustrate the crucial key passages for a successful subcutaneous implantation of radio-transmitters and carotid artery cannulation in mice. We also include examples of long-term blood pressure activity taken from freely moving mice after a period of post-surgery recovery. Following this procedure will allow reliable direct blood pressure recordings from multiple animals simultaneously.

  16. Determination of absolute expression profiles using multiplexed miRNA analysis

    PubMed Central

    Song, Jee Hoon; Cheng, Yulan; Saeui, Christopher T.; Cheung, Douglas G.; Croce, Carlo M.; Yarema, Kevin J.; Meltzer, Stephen J.; Liu, Kelvin J.; Wang, Tza-Huei

    2017-01-01

    Accurate measurement of miRNA expression is critical to understanding their role in gene expression as well as their application as disease biomarkers. Correct identification of changes in miRNA expression rests on reliable normalization to account for biological and technological variance between samples. Ligo-miR is a multiplex assay designed to rapidly measure absolute miRNA copy numbers, thus reducing dependence on biological controls. It uses a simple 2-step ligation process to generate length coded products that can be quantified using a variety of DNA sizing methods. We demonstrate Ligo-miR’s ability to quantify miRNA expression down to 20 copies per cell sensitivity, accurately discriminate between closely related miRNA, and reliably measure differential changes as small as 1.2-fold. Then, benchmarking studies were performed to show the high correlation between Ligo-miR, microarray, and TaqMan qRT-PCR. Finally, Ligo-miR was used to determine copy number profiles in a number of breast, esophageal, and pancreatic cell lines and to demonstrate the utility of copy number analysis for providing layered insight into expression profile changes. PMID:28704432

  17. Can the three pore model correctly describe peritoneal transport of protein?

    PubMed

    Waniewski, Jacek; Poleszczuk, Jan; Antosiewicz, Stefan; Baczynński, Daniel; Gałach, Magda; Pietribiasi, Mauro; Wanńkowicz, Zofia

    2014-01-01

    The three pore model (3PM) includes large pores for the description of protein leak to the peritoneal cavity during peritoneal dialysis. However, the reliability of this description has been not fully tested against clinical data yet. Peritoneal transport parameters were estimated using 3PM, extended 3p model (with estimation of fraction of large pores, ext3PM), ext3PM with modified size of pores and proteins (mext3PM), and simplified two pore (2PM, small and ultrasmall pores) models for 32 patients on peritoneal dialysis investigated using the sequential peritoneal equilibration test (consecutive peritoneal equilibration test [PET]: glucose 2.27%, 4 h, and miniPET: glucose 3.86%, 1 h). Urea, creatinine, glucose, sodium, phosphate, albumin, and IgM concentrations were measured in dialysis fluid and plasma. Ext3PM and mext3PM, with large pore fraction of about 0.14, provided a good description of fluid and small solute kinetics, but their predictions for albumin transport were less accurate. Two pore model precisely described the data on fluid and small solute transport. The 3p models could not describe the diffusive-convective transport of albumin as precisely as the transport of fluid, small solutes, and IgM. The 2p model (not applicable for proteins) was an efficient tool for modeling fluid and small solute transport.

  18. SmartGrain: high-throughput phenotyping software for measuring seed shape through image analysis.

    PubMed

    Tanabata, Takanari; Shibaya, Taeko; Hori, Kiyosumi; Ebana, Kaworu; Yano, Masahiro

    2012-12-01

    Seed shape and size are among the most important agronomic traits because they affect yield and market price. To obtain accurate seed size data, a large number of measurements are needed because there is little difference in size among seeds from one plant. To promote genetic analysis and selection for seed shape in plant breeding, efficient, reliable, high-throughput seed phenotyping methods are required. We developed SmartGrain software for high-throughput measurement of seed shape. This software uses a new image analysis method to reduce the time taken in the preparation of seeds and in image capture. Outlines of seeds are automatically recognized from digital images, and several shape parameters, such as seed length, width, area, and perimeter length, are calculated. To validate the software, we performed a quantitative trait locus (QTL) analysis for rice (Oryza sativa) seed shape using backcrossed inbred lines derived from a cross between japonica cultivars Koshihikari and Nipponbare, which showed small differences in seed shape. SmartGrain removed areas of awns and pedicels automatically, and several QTLs were detected for six shape parameters. The allelic effect of a QTL for seed length detected on chromosome 11 was confirmed in advanced backcross progeny; the cv Nipponbare allele increased seed length and, thus, seed weight. High-throughput measurement with SmartGrain reduced sampling error and made it possible to distinguish between lines with small differences in seed shape. SmartGrain could accurately recognize seed not only of rice but also of several other species, including Arabidopsis (Arabidopsis thaliana). The software is free to researchers.

  19. Micrometeoroid and Lunar Secondary Ejecta Flux Measurements: Comparison of Three Acoustic Systems

    NASA Technical Reports Server (NTRS)

    Corsaro, R. D.; Giovane, F.; Liou, Jer-Chyi; Burtchell, M.; Pisacane, V.; Lagakos, N.; Williams, E.; Stansbery, E.

    2010-01-01

    This report examines the inherent capability of three large-area acoustic sensor systems and their applicability for micrometeoroids (MM) and lunar secondary ejecta (SE) detection and characterization for future lunar exploration activities. Discussion is limited to instruments that can be fabricated and deployed with low resource requirements. Previously deployed impact detection probes typically have instrumented capture areas less than 0.2 square meters. Since the particle flux decreases rapidly with increased particle size, such small-area sensors rarely encounter particles in the size range above 50 microns, and even their sampling the population above 10 microns is typically limited. Characterizing the sparse dust population in the size range above 50 microns requires a very large-area capture instrument. However it is also important that such an instrument simultaneously measures the population of the smaller particles, so as to provide a complete instantaneous snapshot of the population. For lunar or planetary surface studies, the system constraints are significant. The instrument must be as large as possible to sample the population of the largest MM. This is needed to reliably assess the particle impact risks and to develop cost-effective shielding designs for habitats, astronauts, and critical instrument. The instrument should also have very high sensitivity to measure the flux of small and slow SE particles. is the SE environment is currently poorly characterized, and possess a contamination risk to machinery and personnel involved in exploration. Deployment also requires that the instrument add very little additional mass to the spacecraft. Three acoustic systems are being explored for this application.

  20. Small bowel capsule endoscopy in 2007: Indications, risks and limitations

    PubMed Central

    Rondonotti, Emanuele; Villa, Federica; Mulder, Chris JJ; Jacobs, Maarten AJM; de Franchis, Roberto

    2007-01-01

    Capsule endoscopy has revoluzionized the study of the small bowel by providing a reliable method to evaluate, endoscopically, the entire small bowel. In the last six years several papers have been published exploring the possible role of this examination in different clinical conditions. At the present time capsule endoscopy is generally recommended as a third examination, after negative bidirectional endoscopy, in patients with obscure gastrointestinal bleeding. A growing body of evidence suggests also an important role for this examination in other clinical conditions such as Crohn’s disease, celiac disease, small bowel polyposis syndromes or small bowel tumors. The main complication of this examination is the retention of the device at the site of a previously unknown small bowel stricture. However there are also some other open issues mainly due to technical limitations of this tool (which is not driven from remote control, is unable to take biopsies, to insufflate air, to suck fluids or debris and sometimes to correctly size and locate lesions).The recently developed double balloon enteroscope, owing to its capability to explore a large part of the small bowel and to take targeted biopsies, although being invasive and time consuming, can overcome some limitations of capsule endoscopy. At the present time, in the majority of clinical conditions (i.e. obscure GI bleeding), the winning strategy seems to be to couple these two techniques to explore the small bowel in a painless, safe and complete way (with capsule endoscopy) and to define and treat the lesions identified (with double balloon enteroscopy). PMID:18069752

  1. Damage modeling of small-scale experiments on dental enamel with hierarchical microstructure.

    PubMed

    Scheider, I; Xiao, T; Yilmaz, E; Schneider, G A; Huber, N; Bargmann, S

    2015-03-01

    Dental enamel is a highly anisotropic and heterogeneous material, which exhibits an optimal reliability with respect to the various loads occurring over years. In this work, enamel's microstructure of parallel aligned rods of mineral fibers is modeled and mechanical properties are evaluated in terms of strength and toughness with the help of a multiscale modeling method. The established model is validated by comparing it with the stress-strain curves identified by microcantilever beam experiments extracted from these rods. Moreover, in order to gain further insight in the damage-tolerant behavior of enamel, the size of crystallites below which the structure becomes insensitive to flaws is studied by a microstructural finite element model. The assumption regarding the fiber strength is verified by a numerical study leading to accordance of fiber size and flaw tolerance size, and the debonding strength is estimated by optimizing the failure behavior of the microstructure on the hierarchical level above the individual fibers. Based on these well-grounded properties, the material behavior is predicted well by homogenization of a representative unit cell including damage, taking imperfections (like microcracks in the present case) into account. Copyright © 2014 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  2. Fast synthesis of topographic mask effects based on rigorous solutions

    NASA Astrophysics Data System (ADS)

    Yan, Qiliang; Deng, Zhijie; Shiely, James

    2007-10-01

    Topographic mask effects can no longer be ignored at technology nodes of 45 nm, 32 nm and beyond. As feature sizes become comparable to the mask topographic dimensions and the exposure wavelength, the popular thin mask model breaks down, because the mask transmission no longer follows the layout. A reliable mask transmission function has to be derived from Maxwell equations. Unfortunately, rigorous solutions of Maxwell equations are only manageable for limited field sizes, but impractical for full-chip optical proximity corrections (OPC) due to the prohibitive runtime. Approximation algorithms are in demand to achieve a balance between acceptable computation time and tolerable errors. In this paper, a fast algorithm is proposed and demonstrated to model topographic mask effects for OPC applications. The ProGen Topographic Mask (POTOMAC) model synthesizes the mask transmission functions out of small-sized Maxwell solutions from a finite-difference-in-time-domain (FDTD) engine, an industry leading rigorous simulator of topographic mask effect from SOLID-E. The integral framework presents a seamless solution to the end user. Preliminary results indicate the overhead introduced by POTOMAC is contained within the same order of magnitude in comparison to the thin mask approach.

  3. Lightweight MgB2 superconducting 10 MW wind generator

    NASA Astrophysics Data System (ADS)

    Marino, I.; Pujana, A.; Sarmiento, G.; Sanz, S.; Merino, J. M.; Tropeano, M.; Sun, J.; Canosa, T.

    2016-02-01

    The offshore wind market demands a higher power rate and more reliable turbines in order to optimize capital and operational costs. The state-of-the-art shows that both geared and direct-drive conventional generators are difficult to scale up to 10 MW and beyond due to their huge size and weight. Superconducting direct-drive wind generators are considered a promising solution to achieve lighter weight machines. This work presents an innovative 10 MW 8.1 rpm direct-drive partial superconducting generator using MgB2 wire for the field coils. It has a warm iron rotor configuration with the superconducting coils working at 20 K while the rotor core and the armature are at ambient temperature. A cooling system based on cryocoolers installed in the rotor extracts the heat from the superconducting coils by conduction. The generator's main parameters are compared against a permanent magnet reference machine, showing a significant weight and size reduction. The 10 MW superconducting generator concept will be experimentally validated with a small-scale magnetic machine, which has innovative components such as superconducting coils, modular cryostats and cooling systems, and will have similar size and characteristics as the 10 MW generator.

  4. Evaluation of a formula that categorizes female gray wolf breeding status by nipple size

    USGS Publications Warehouse

    Barber-Meyer, Shannon M.; Mech, L. David

    2015-01-01

    The proportion by age class of wild Canis lupus (Gray Wolf) females that reproduce in any given year remains unclear; thus, we evaluated the applicability to our long-term (1972–2013) data set of the Mech et al. (1993) formula that categorizes female Gray Wolf breeding status by nipple size and time of year. We used the formula to classify Gray Wolves from 68 capture events into 4 categories (yearling, adult non-breeder, former breeder, current breeder). To address issues with small sample size and variance, we created an ambiguity index to allow some Gray Wolves to be classed into 2 categories. We classified 20 nipple measurements ambiguously: 16 current or former breeder, 3 former or adult non-breeder, and 1 yearling or adult non-breeder. The formula unambiguously classified 48 (71%) of the nipple measurements; based on supplemental field evidence, at least 5 (10%) of these were incorrect. When used in conjunction with an ambiguity index we developed and with corrections made for classifications involving very large nipples, and supplemented with available field evidence, the Mech et al. (1993) formula provided reasonably reliable classification of breeding status in wild female Gray Wolves.

  5. Head-body ratio as a visual cue for stature in people and sculptural art.

    PubMed

    Mather, George

    2010-01-01

    Body size is crucial for determining the outcome of competition for resources and mates. Many species use acoustic cues to measure caller body size. Vision is the pre-eminent sense for humans, but visual depth cues are of limited utility in judgments of absolute body size. The reliability of internal body proportion as a potential cue to stature was assessed with a large sample of anthropometric data, and the ratio of head height to body height (HBR) was found to be highly correlated with stature. A psychophysical experiment was carried out to investigate whether the cue actually influences stature judgments. Participants were shown pairs of photographs of human figures in which HBR had been manipulated systematically, and asked to select the figure that appeared taller. Results showed that figures with a relatively small HBR were consistently perceived as taller than figures with a relatively large HBR. Many classical statues such as Michelangelo's David depart from the classical proportions defined in Leonardo's Vitruvian Man. A supplementary experiment showed that perceived stature in classical statues also depends on HBR. Michelangelo's David was created with the HBR of a man 165 cm (5 ft 5 in) tall.

  6. Small Stirling dynamic isotope power system for robotic space missions

    NASA Technical Reports Server (NTRS)

    Bents, D. J.

    1992-01-01

    The design of a multihundred-watt Dynamic Isotope Power System (DIPS), based on the U.S. Department of Energy (DOE) General Purpose Heat Source (GPHS) and small (multihundred-watt) free-piston Stirling engine (FPSE), is being pursued as a potential lower cost alternative to radioisotope thermoelectric generators (RTG's). The design is targeted at the power needs of future unmanned deep space and planetary surface exploration missions ranging from scientific probes to Space Exploration Initiative precursor missions. Power level for these missions is less than a kilowatt. The incentive for any dynamic system is that it can save fuel and reduce costs and radiological hazard. Unlike DIPS based on turbomachinery conversion (e.g. Brayton), this small Stirling DIPS can be advantageously scaled to multihundred-watt unit size while preserving size and mass competitiveness with RTG's. Stirling conversion extends the competitive range for dynamic systems down to a few hundred watts--a power level not previously considered for dynamic systems. The challenge for Stirling conversion will be to demonstrate reliability and life similar to RTG experience. Since the competitive potential of FPSE as an isotope converter was first identified, work has focused on feasibility of directly integrating GPHS with the Stirling heater head. Thermal modeling of various radiatively coupled heat source/heater head geometries has been performed using data furnished by the developers of FPSE and GPHS. The analysis indicates that, for the 1050 K heater head configurations considered, GPHS fuel clad temperatures remain within acceptable operating limits. Based on these results, preliminary characterizations of multihundred-watt units have been established.

  7. Neighbouring populations, opposite dynamics: influence of body size and environmental variation on the demography of stream-resident brown trout (Salmo trutta).

    PubMed

    Fernández-Chacón, Albert; Genovart, Meritxell; Álvarez, David; Cano, José M; Ojanguren, Alfredo F; Rodriguez-Muñoz, Rolando; Nicieza, Alfredo G

    2015-06-01

    In organisms such as fish, where body size is considered an important state variable for the study of their population dynamics, size-specific growth and survival rates can be influenced by local variation in both biotic and abiotic factors, but few studies have evaluated the complex relationships between environmental variability and size-dependent processes. We analysed a 6-year capture-recapture dataset of brown trout (Salmo trutta) collected at 3 neighbouring but heterogeneous mountain streams in northern Spain with the aim of investigating the factors shaping the dynamics of local populations. The influence of body size and water temperature on survival and individual growth was assessed under a multi-state modelling framework, an extension of classical capture-recapture models that considers the state (i.e. body size) of the individual in each capture occasion and allows us to obtain state-specific demographic rates and link them to continuous environmental variables. Individual survival and growth patterns varied over space and time, and evidence of size-dependent survival was found in all but the smallest stream. At this stream, the probability of reaching larger sizes was lower compared to the other wider and deeper streams. Water temperature variables performed better in the modelling of the highest-altitude population, explaining over a 99 % of the variability in maturation transitions and survival of large fish. The relationships between body size, temperature and fitness components found in this study highlight the utility of multi-state approaches to investigate small-scale demographic processes in heterogeneous environments, and to provide reliable ecological knowledge for management purposes.

  8. Size matters: relationships between body size and body mass of common coastal, aquatic invertebrates in the Baltic Sea

    PubMed Central

    Austin, Åsa; Bergström, Ulf; Donadi, Serena; Eriksson, Britas D.H.K.; Hansen, Joakim; Sundblad, Göran

    2017-01-01

    Background Organism biomass is one of the most important variables in ecological studies, making biomass estimations one of the most common laboratory tasks. Biomass of small macroinvertebrates is usually estimated as dry mass or ash-free dry mass (hereafter ‘DM’ vs. ‘AFDM’) per sample; a laborious and time consuming process, that often can be speeded up using easily measured and reliable proxy variables like body size or wet (fresh) mass. Another common way of estimating AFDM (one of the most accurate but also time-consuming estimates of biologically active tissue mass) is the use of AFDM/DM ratios as conversion factors. So far, however, these ratios typically ignore the possibility that the relative mass of biologically active vs. non-active support tissue (e.g., protective exoskeleton or shell)—and therefore, also AFDM/DM ratios—may change with body size, as previously shown for taxa like spiders, vertebrates and trees. Methods We collected aquatic, epibenthic macroinvertebrates (>1 mm) in 32 shallow bays along a 360 km stretch of the Swedish coast along the Baltic Sea; one of the largest brackish water bodies on Earth. We then estimated statistical relationships between the body size (length or height in mm), body dry mass and ash-free dry mass for 14 of the most common taxa; five gastropods, three bivalves, three crustaceans and three insect larvae. Finally, we statistically estimated the potential influence of body size on the AFDM/DM ratio per taxon. Results For most taxa, non-linear regression models describing the power relationship between body size and (i) DM and (ii) AFDM fit the data well (as indicated by low SE and high R2). Moreover, for more than half of the taxa studied (including the vast majority of the shelled molluscs), body size had a negative influence on organism AFDM/DM ratios. Discussion The good fit of the modelled power relationships suggests that the constants reported here can be used to quickly estimate organism dry- and ash-free dry mass based on body size, thereby freeing up considerable work resources. However, the considerable differences in constants between taxa emphasize the need for taxon-specific relationships, and the potential dangers associated with ignoring body size. The negative influence of body size on the AFDM/DM ratio found in a majority of the molluscs could be caused by increasingly thicker shells with organism age, and/or spawning-induced loss of biologically active tissue in adults. Consequently, future studies utilizing AFDM/DM (and presumably also AFDM/wet mass) ratios should carefully assess the potential influence of body size to ensure more reliable estimates of organism body mass. PMID:28149685

  9. Size matters: relationships between body size and body mass of common coastal, aquatic invertebrates in the Baltic Sea.

    PubMed

    Eklöf, Johan; Austin, Åsa; Bergström, Ulf; Donadi, Serena; Eriksson, Britas D H K; Hansen, Joakim; Sundblad, Göran

    2017-01-01

    Organism biomass is one of the most important variables in ecological studies, making biomass estimations one of the most common laboratory tasks. Biomass of small macroinvertebrates is usually estimated as dry mass or ash-free dry mass (hereafter 'DM' vs. 'AFDM') per sample; a laborious and time consuming process, that often can be speeded up using easily measured and reliable proxy variables like body size or wet (fresh) mass. Another common way of estimating AFDM (one of the most accurate but also time-consuming estimates of biologically active tissue mass) is the use of AFDM/DM ratios as conversion factors. So far, however, these ratios typically ignore the possibility that the relative mass of biologically active vs. non-active support tissue (e.g., protective exoskeleton or shell)-and therefore, also AFDM/DM ratios-may change with body size, as previously shown for taxa like spiders, vertebrates and trees. We collected aquatic, epibenthic macroinvertebrates (>1 mm) in 32 shallow bays along a 360 km stretch of the Swedish coast along the Baltic Sea; one of the largest brackish water bodies on Earth. We then estimated statistical relationships between the body size (length or height in mm), body dry mass and ash-free dry mass for 14 of the most common taxa; five gastropods, three bivalves, three crustaceans and three insect larvae. Finally, we statistically estimated the potential influence of body size on the AFDM/DM ratio per taxon. For most taxa, non-linear regression models describing the power relationship between body size and (i) DM and (ii) AFDM fit the data well (as indicated by low SE and high R 2 ). Moreover, for more than half of the taxa studied (including the vast majority of the shelled molluscs), body size had a negative influence on organism AFDM/DM ratios. The good fit of the modelled power relationships suggests that the constants reported here can be used to quickly estimate organism dry- and ash-free dry mass based on body size, thereby freeing up considerable work resources. However, the considerable differences in constants between taxa emphasize the need for taxon-specific relationships, and the potential dangers associated with ignoring body size. The negative influence of body size on the AFDM/DM ratio found in a majority of the molluscs could be caused by increasingly thicker shells with organism age, and/or spawning-induced loss of biologically active tissue in adults. Consequently, future studies utilizing AFDM/DM (and presumably also AFDM/wet mass) ratios should carefully assess the potential influence of body size to ensure more reliable estimates of organism body mass.

  10. A 2D silicon detector array for quality assurance in small field dosimetry: DUO.

    PubMed

    Shukaili, Khalsa Al; Petasecca, Marco; Newall, Matthew; Espinoza, Anthony; Perevertaylo, Vladimir L; Corde, Stéphanie; Lerch, Michael; Rosenfeld, Anatoly B

    2017-02-01

    Nowadays, there are many different applications that use small fields in radiotherapy treatments. The dosimetry of small radiation fields is not trivial due to the problems associated with lateral disequilibrium and source occlusion and requires reliable quality assurance (QA). Ideally such a QA tool should provide high spatial resolution, minimal beam perturbation and real time fast measurements. Many different types of silicon diode arrays are used for QA in radiotherapy; however, their application in small filed dosimetry is limited, in part, due to a lack of spatial resolution. The Center of Medical Radiation Physics (CMRP) has developed a new generation of a monolithic silicon diode array detector that will be useful for small field dosimetry in SRS/SRT. The objective of this study is to characterize a monolithic silicon diode array designed for dosimetry QA in SRS/SRT named DUO that is arranged as two orthogonal 1D arrays with 0.2 mm pitch. DUO is two orthogonal 1D silicon detector arrays in a monolithic crystal. Each orthogonal array contains 253 small pixels with size 0.04 × 0.8 mm 2 and three central pixels are with a size of 0.18 × 0.18 mm 2 each. The detector pitch is 0.2 mm and total active area is 52 × 52 mm 2 . The response of the DUO silicon detector was characterized in terms of dose per pulse, percentage depth dose, and spatial resolution in a radiation field incorporating high gradients. Beam profile of small fields and output factors measured on a Varian 2100EX LINAC in a 6 MV radiation fields of square dimensions and sized from 0.5 × 0.5 cm 2 to 5 × 5 cm 2 . The DUO response was compared under the same conditions with EBT3 films and an ionization chamber. The DUO detector shows a dose per pulse dependence of 5% for a range of dose rates from 2.7 × 10 -4 to 1.2 × 10 -4 Gy/pulse and 23% when the rate is further reduced to 2.8 × 10 -5 Gy/pulse. The percentage depth dose measured to 25 cm depth in solid water phantom beyond the surface and for a field size of 10 × 10 cm 2 agrees with that measured using a Markus IC within 1.5%. The beam profiles in both X and Y orthogonal directions showed a good match with EBT3 film, where the FWHM agreed within 1% and penumbra widths within 0.5 mm. The effect of an air gap above the DUO detector has also been studied. The output factor for field sizes ranging from 0.5 × 0.5 cm 2 to 5 × 5 cm 2 measured by the DUO detector with a 0.5 mm air gap above silicon surface agrees with EBT3 film and MOSkin detectors within 1.8%. The CMRP's monolithic silicon detector array, DUO, is suitable for SRS/SRT dosimetry and QA because of its very high spatial resolution (0.2 mm) and real time operation. © 2016 American Association of Physicists in Medicine.

  11. 77 FR 58739 - Small Business Size Standards: Educational Services

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-09-24

    ... programs, SBA establishes small business size definitions (referred to as size standards) for private... programs effectively, SBA establishes distinct definitions to determine which businesses are deemed small... businesses definitions (15 U.S.C. 632(a)). The Act also requires that small business definitions vary to...

  12. 77 FR 10943 - Small Business Size Standards: Transportation and Warehousing

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-02-24

    ... assistance programs, SBA establishes small business size definitions (referred to as size standards) for... business concern * * *'' Sec. 3(a)(2)(C)(ii)(II) [emphasis added]. Third, SBA's existing definitions of... establishes distinct definitions to determine which businesses are deemed small businesses. The Small Business...

  13. High-throughput infrared spectrometer for standoff chemical detection

    NASA Astrophysics Data System (ADS)

    Chadha, Suneet; Stevenson, Chuck; Curtiss, Lawrence E.

    1999-01-01

    Advanced autonomous detection of chemical warfare agents and other organic materials has long been a major military concern. While significant advances have recently been accomplished in remote spectral sensing using rugged FTIRs with point detectors, efforts towards spatial chemical discrimination have been lacking. Foster-Miller, Inc. has developed a radically different mid-IR and long wave IR spectrometer for standoff detection of chemical warfare agents and other molecular species.This no moving parts device will eliminate the cost, complexity, reliability and bandwidth/resolution problems associated with either Fabry Perot or Michelson Interferometer based approaches currently under consideration. Given the small size and performance insensitivity to on-board vibration, high EMI, thermal variations, the proposed optic would easily adapt cryocooling and field deployable requirements for low radiance detection.

  14. A Comparative XAFS Study of Gold-thiolate Nanoparticles and Nanoclusters

    NASA Astrophysics Data System (ADS)

    Chevrier, D. M.; Chatt, A.; Sham, T. K.; Zhang, P.

    2013-04-01

    Tiopronin-capped gold nanoparticles and gold nanoclusters of sizes 3.0 and 1.5 nm, respectively, were investigated with XAFS at the gold L3-edge. The specific EXAFS fitting procedure is discussed for obtaining reliable fit parameters for each system. The difficulties and challenges faced when analysing EXAFS data for gold nanoparticles and nanoclusters are also mentioned. Fitting results for gold nanoparticles reveal a small amount of surface Au-thiolate interactions with a large Au-Au metal core. For gold nanoclusters, only a one-shell fit was obtainable. Instead of Au-Au metal core, long-range interactions are expected for gold nanoclusters. Tiopronin-capped gold nanoclusters are proposed to be polymeric in nature, which helps explain the observed red luminescence.

  15. Structure and kinematics of the broad-line regions in active galaxies from IUE variability data

    NASA Technical Reports Server (NTRS)

    Koratkar, Anuradha P.; Gaskell, C. Martin

    1991-01-01

    IUE archival data are used here to investigate the structure nad kinematics of the broad-line regions (BLRs) in nine AGN. It is found that the centroid of the line-continuum cross-correlation functions (CCFs) can be determined with reasonable reliability. The errors in BLR size estimates from CCFs for irregularly sampled light curves are fairly well understood. BLRs are found to have small luminosity-weighted radii, and lines of high ionization tend to be emitted closer to the central source than lines of low ionization, especially for low-luminosity objects. The motion of the gas is gravity-dominated with both pure inflow and pure outflow of high-velocity gas being excluded at a high confidence level for certain geometries.

  16. Fabrication of Tunnel Junctions For Direct Detector Arrays With Single-Electron Transistor Readout Using Electron-Beam Lithography

    NASA Technical Reports Server (NTRS)

    Stevenson, T. R.; Hsieh, W.-T.; Li, M. J.; Stahle, C. M.; Rhee, K. W.; Teufel, J.; Schoelkopf, R. J.

    2002-01-01

    This paper will describe the fabrication of small aluminum tunnel junctions for applications in astronomy. Antenna-coupled superconducting tunnel junctions with integrated single-electron transistor readout have the potential for photon-counting sensitivity at sub-millimeter wavelengths. The junctions for the detector and single-electron transistor can be made with electron-beam lithography and a standard self-aligned double-angle deposition process. However, high yield and uniformity of the junctions is required for large-format detector arrays. This paper will describe how measurement and modification of the sensitivity ratio in the resist bilayer was used to greatly improve the reliability of forming devices with uniform, sub-micron size, low-leakage junctions.

  17. Mechanical Design of Downhole Tractor Based on Two-Way Self-locking Mechanism

    NASA Astrophysics Data System (ADS)

    Fang, Delei; Shang, Jianzhong; Luo, Zirong; Wu, Guoheng; Liu, Yiying

    2018-03-01

    Based on the technology of horizontal well tractor, a kind of downhole tractor was developed which can realize Two-Way self-locking function. Aiming at the needs of horizontal well logging to realize the target of small size, high traction and high reliability, the tractor selects unique heart-shaped CAM as the locking mechanism. The motion principle of telescopic downhole tractor, the design of mechanical structure and locking principle of the locking mechanism are all analyzed. The mathematical expressions of traction are obtained by mechanical analysis of parallel support rod in the locking mechanism. The force analysis and contour design of the heart-shaped CAM are performed, which can lay the foundation for the development of tractor prototype.

  18. Concatenated coding systems employing a unit-memory convolutional code and a byte-oriented decoding algorithm

    NASA Technical Reports Server (NTRS)

    Lee, L. N.

    1976-01-01

    Concatenated coding systems utilizing a convolutional code as the inner code and a Reed-Solomon code as the outer code are considered. In order to obtain very reliable communications over a very noisy channel with relatively small coding complexity, it is proposed to concatenate a byte oriented unit memory convolutional code with an RS outer code whose symbol size is one byte. It is further proposed to utilize a real time minimal byte error probability decoding algorithm, together with feedback from the outer decoder, in the decoder for the inner convolutional code. The performance of the proposed concatenated coding system is studied, and the improvement over conventional concatenated systems due to each additional feature is isolated.

  19. Reliability of Computerized Neurocognitive Tests for Concussion Assessment: A Meta-Analysis.

    PubMed

    Farnsworth, James L; Dargo, Lucas; Ragan, Brian G; Kang, Minsoo

    2017-09-01

      Although widely used, computerized neurocognitive tests (CNTs) have been criticized because of low reliability and poor sensitivity. A systematic review was published summarizing the reliability of Immediate Post-Concussion Assessment and Cognitive Testing (ImPACT) scores; however, this was limited to a single CNT. Expansion of the previous review to include additional CNTs and a meta-analysis is needed. Therefore, our purpose was to analyze reliability data for CNTs using meta-analysis and examine moderating factors that may influence reliability.   A systematic literature search (key terms: reliability, computerized neurocognitive test, concussion) of electronic databases (MEDLINE, PubMed, Google Scholar, and SPORTDiscus) was conducted to identify relevant studies.   Studies were included if they met all of the following criteria: used a test-retest design, involved at least 1 CNT, provided sufficient statistical data to allow for effect-size calculation, and were published in English.   Two independent reviewers investigated each article to assess inclusion criteria. Eighteen studies involving 2674 participants were retained. Intraclass correlation coefficients were extracted to calculate effect sizes and determine overall reliability. The Fisher Z transformation adjusted for sampling error associated with averaging correlations. Moderator analyses were conducted to evaluate the effects of the length of the test-retest interval, intraclass correlation coefficient model selection, participant demographics, and study design on reliability. Heterogeneity was evaluated using the Cochran Q statistic.   The proportion of acceptable outcomes was greatest for the Axon Sports CogState Test (75%) and lowest for the ImPACT (25%). Moderator analyses indicated that the type of intraclass correlation coefficient model used significantly influenced effect-size estimates, accounting for 17% of the variation in reliability.   The Axon Sports CogState Test, which has a higher proportion of acceptable outcomes and shorter test duration relative to other CNTs, may be a reliable option; however, future studies are needed to compare the diagnostic accuracy of these instruments.

  20. Solid oxide fuel cell cathode infiltrate particle size control and oxygen surface exchange resistance determination

    NASA Astrophysics Data System (ADS)

    Burye, Theodore E.

    Over the past decade, nano-sized Mixed Ionic Electronic Conducting (MIEC) -- micro-sized Ionic Conducting (IC) composite cathodes produced by the infiltration method have received much attention in the literature due to their low polarization resistance (RP) at intermediate (500-700°C) operating temperatures. Small infiltrated MIEC oxide nano-particle size and low intrinsic MIEC oxygen surface exchange resistance (Rs) have been two critical factors allowing these Nano-Micro-Composite Cathodes (NMCCs) to achieve high performance and/or low temperature operation. Unfortunately, previous studies have not found a reliable method to control or reduce infiltrated nano-particle size. In addition, controversy exists on the best MIEC infiltrate composition because: 1) Rs measurements on infiltrated MIEC particles are presently unavailable in the literature, and 2) bulk and thin film Rs measurements on nominally identical MIEC compositions often vary by up to 3 orders of magnitude. Here, two processing techniques, precursor nitrate solution desiccation and ceria oxide pre-infiltration, were developed to systematically produce a reduction in the average La0.6Sr0.4Co0.8Fe 0.2O3-delta (LSCF) infiltrated nano-particle size from 50 nm to 22 nm. This particle size reduction reduced the SOFC operating temperature, (defined as the temperature where RP=0.1 Ocm 2) from 650°C to 540°C. In addition, Rs values for infiltrated MIEC particles were determined for the first time through finite element modeling calculations on 3D Focused Ion Beam-Scanning Electron Microscope (FIB-SEM) reconstructions of electrochemically characterized infiltrated electrodes.

  1. PIYAS-proceeding to intelligent service oriented memory allocation for flash based data centric sensor devices in wireless sensor networks.

    PubMed

    Rizvi, Sanam Shahla; Chung, Tae-Sun

    2010-01-01

    Flash memory has become a more widespread storage medium for modern wireless devices because of its effective characteristics like non-volatility, small size, light weight, fast access speed, shock resistance, high reliability and low power consumption. Sensor nodes are highly resource constrained in terms of limited processing speed, runtime memory, persistent storage, communication bandwidth and finite energy. Therefore, for wireless sensor networks supporting sense, store, merge and send schemes, an efficient and reliable file system is highly required with consideration of sensor node constraints. In this paper, we propose a novel log structured external NAND flash memory based file system, called Proceeding to Intelligent service oriented memorY Allocation for flash based data centric Sensor devices in wireless sensor networks (PIYAS). This is the extended version of our previously proposed PIYA [1]. The main goals of the PIYAS scheme are to achieve instant mounting and reduced SRAM space by keeping memory mapping information to a very low size of and to provide high query response throughput by allocation of memory to the sensor data by network business rules. The scheme intelligently samples and stores the raw data and provides high in-network data availability by keeping the aggregate data for a longer period of time than any other scheme has done before. We propose effective garbage collection and wear-leveling schemes as well. The experimental results show that PIYAS is an optimized memory management scheme allowing high performance for wireless sensor networks.

  2. Clinical manifestations that predict abnormal brain computed tomography (CT) in children with minor head injury.

    PubMed

    Alharthy, Nesrin; Al Queflie, Sulaiman; Alyousef, Khalid; Yunus, Faisel

    2015-01-01

    Computed tomography (CT) used in pediatric pediatrics brain injury (TBI) to ascertain neurological manifestations. Nevertheless, this practice is associated with adverse effects. Reports in the literature suggest incidents of morbidity and mortality in children due to exposure to radiation. Hence, it is found imperative to search for a reliable alternative. The aim of this study is to find a reliable clinical alternative to detect an intracranial injury without resorting to the CT. Retrospective cross-sectional study was undertaken in patients (1-14 years) with blunt head injury and having a Glasgow Coma Scale (GCS) of 13-15 who had CT performed on them. Using statistical analysis, the correlation between clinical examination and positive CT manifestation is analyzed for different age-groups and various mechanisms of injury. No statistically significant association between parameteres such as Loss of Consciousness, 'fall' as mechanism of injury, motor vehicle accidents (MVA), more than two discrete episodes of vomiting and the CT finding of intracranial injury could be noted. Analyzed data have led to believe that GCS of 13 at presentation is the only important clinical predictor of intracranial injury. Retrospective data, small sample size and limited number of factors for assessing clinical manifestation might present constraints on the predictive rule that was derived from this review. Such limitations notwithstanding, the decision to determine which patients should undergo neuroimaging is encouraged to be based on clinical judgments. Further analysis with higher sample sizes may be required to authenticate and validate findings.

  3. Modified Right Heart Contrast Echocardiography Versus Traditional Method in Diagnosis of Right-to-Left Shunt: A Comparative Study.

    PubMed

    Wang, Yi; Zeng, Jie; Yin, Lixue; Zhang, Mei; Hou, Dailun

    2016-01-01

    The purpose of this study was to evaluate the reliability, effectiveness, and safety of modified right heart contrast transthoracic echocardiography (cTTE) in comparison with the traditional method. We performed a modified right heart cTTE using saline mixed with a small sample of patient's own blood. Samples were agitated with varying intensity. This study protocol involved microscopic analysis and patient evaluation. 1. Microscopic analysis: After two contrast samples had been agitated 10 or 20 times, they underwent a comparison of bubble size, bubble number, and red blood cell morphology. 2. Patient analysis: 40 patients with suspected RLS (right- to-left shunt) were enrolled. All patients underwent right heart contrast echocardiography. Oxygen saturation, transit time and duration, presence of RLS, change in indirect bilirubin and urobilinogen concentrations were compared afterward. Modified method generated more bubbles (P<0.05), but the differences in bubble size were not significant (P>0.05). Twenty-four patients were diagnosed with RLS (60%) using the modified method compared to 16 patients (40%) with the traditional method. The transit time of ASb20 group was the shortest (P<0.05). However, the duration time in this group was much longer (P<0.05). Also, in semi-quantitative analysis mean rank of RLS was higher after injecting the modified contrast agent agitated 20 times (P<0.05). Modified right heart contrast echocardiography is a reliable, effective and safe method of detecting cardiovascular RLS.

  4. Flow dichroism as a reliable method to measure the hydrodynamic aspect ratio of gold nanoparticles.

    PubMed

    Reddy, Naveen Krishna; Pérez-Juste, Jorge; Pastoriza-Santos, Isabel; Lang, Peter R; Dhont, Jan K G; Liz-Marzán, Luis M; Vermant, Jan

    2011-06-28

    Particle shape plays an important role in controlling the optical, magnetic, and mechanical properties of nanoparticle suspensions as well as nanocomposites. However, characterizing the size, shape, and the associated polydispersity of nanoparticles is not straightforward. Electron microscopy provides an accurate measurement of the geometric properties, but sample preparation can be laborious, and to obtain statistically relevant data many particles need to be analyzed separately. Moreover, when the particles are suspended in a fluid, it is important to measure their hydrodynamic properties, as they determine aspects such as diffusion and the rheological behavior of suspensions. Methods that evaluate the dynamics of nanoparticles such as light scattering and rheo-optical methods accurately provide these hydrodynamic properties, but do necessitate a sufficient optical response. In the present work, three different methods for characterizing nonspherical gold nanoparticles are critically compared, especially taking into account the complex optical response of these particles. The different methods are evaluated in terms of their versatility to asses size, shape, and polydispersity. Among these, the rheo-optical technique is shown to be the most reliable method to obtain hydrodynamic aspect ratio and polydispersity for nonspherical gold nanoparticles for two reasons. First, the use of the evolution of the orientation angle makes effects of polydispersity less important. Second, the use of an external flow field gives a mathematically more robust relation between particle motion and aspect ratio, especially for particles with relatively small aspect ratios.

  5. Validation of the Mini-OAKHQOL for use in patients with osteoarthritis in Spain.

    PubMed

    Gonzalez Sáenz de Tejada, Marta; Bilbao, Amaia; Herrera, Carmen; García, Lidia; Sarasqueta, Cristina; Escobar, Antonio

    2017-08-01

    The Mini-Osteoarthritis Knee and Hip Quality of Life (Mini-OAKHQOL) questionnaire osteoarthritis is specific to individuals with knee or hip osteoarthritis. The objective of this study was to perform a validation of the Mini-OAKHQOL for use in Spain in terms of its psychometric properties of reliability, validity and responsiveness. Patients with osteoarthritis from the waiting list for a joint replacement completed the OAKHQOL, Short Form 36 Health Survey and Western Ontario and McMaster Universities Osteoarthritis Index. Reliability was assessed in terms of internal consistency and test-retest data, and convergent validity using Spearman's correlation coefficient. Structural validity was investigated by confirmatory factor analysis, and Rasch analysis was used to examine the unidimensionality of the scales. Responsiveness was assessed by calculating effect sizes. Confirmatory factor analysis confirmed the five-factor model, and the results of the Rasch analyses supported the unidimensionality assumption, with infit and outfit statistics. Cronbach's alpha ranged from 0.76 to 0.89 for all except the social dimensions. Statistically significant differences were observed between patients with different degrees of disease severity on all dimensions. There was convergent validity among dimensions expected to be correlated. The OAKHQOL questionnaire showed good responsiveness, with large changes for all dimensions apart from the two social dimensions, which had small effect sizes. Results of the study support the view that the Spanish version of the Mini-OAKHQOL questionnaire is a valid instrument to measure health-related quality of life in patients with osteoarthritis of the lower limb.

  6. Results of a Demonstration Assessment of Passive System Reliability Utilizing the Reliability Method for Passive Systems (RMPS)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bucknor, Matthew; Grabaskas, David; Brunett, Acacia

    2015-04-26

    Advanced small modular reactor designs include many advantageous design features such as passively driven safety systems that are arguably more reliable and cost effective relative to conventional active systems. Despite their attractiveness, a reliability assessment of passive systems can be difficult using conventional reliability methods due to the nature of passive systems. Simple deviations in boundary conditions can induce functional failures in a passive system, and intermediate or unexpected operating modes can also occur. As part of an ongoing project, Argonne National Laboratory is investigating various methodologies to address passive system reliability. The Reliability Method for Passive Systems (RMPS), amore » systematic approach for examining reliability, is one technique chosen for this analysis. This methodology is combined with the Risk-Informed Safety Margin Characterization (RISMC) approach to assess the reliability of a passive system and the impact of its associated uncertainties. For this demonstration problem, an integrated plant model of an advanced small modular pool-type sodium fast reactor with a passive reactor cavity cooling system is subjected to a station blackout using RELAP5-3D. This paper discusses important aspects of the reliability assessment, including deployment of the methodology, the uncertainty identification and quantification process, and identification of key risk metrics.« less

  7. Reliability and agreement in student ratings of the class environment.

    PubMed

    Nelson, Peter M; Christ, Theodore J

    2016-09-01

    The current study estimated the reliability and agreement of student ratings of the classroom environment obtained using the Responsive Environmental Assessment for Classroom Teaching (REACT; Christ, Nelson, & Demers, 2012; Nelson, Demers, & Christ, 2014). Coefficient alpha, class-level reliability, and class agreement indices were evaluated as each index provides important information for different interpretations and uses of student rating scale data. Data for 84 classes across 29 teachers in a suburban middle school were sampled to derive reliability and agreement indices for the REACT subscales across 4 class sizes: 25, 20, 15, and 10. All participating teachers were White and a larger number of 6th-grade classes were included (42%) relative to 7th- (33%) or 8th- (23%) grade classes. Teachers were responsible for a variety of content areas, including language arts (26%), science (26%), math (20%), social studies (19%), communications (6%), and Spanish (3%). Coefficient alpha estimates were generally high across all subscales and class sizes (α = .70-.95); class-mean estimates were greatly impacted by the number of students sampled from each class, with class-level reliability values generally falling below .70 when class size was reduced from 25 to 20. Further, within-class student agreement varied widely across the REACT subscales (mean agreement = .41-.80). Although coefficient alpha and test-retest reliability are commonly reported in research with student rating scales, class-level reliability and agreement are not. The observed differences across coefficient alpha, class-level reliability, and agreement indices provide evidence for evaluating students' ratings of the class environment according to their intended use (e.g., differentiating between classes, class-level instructional decisions). (PsycINFO Database Record (c) 2016 APA, all rights reserved).

  8. An empirical study of flight control software reliability

    NASA Technical Reports Server (NTRS)

    Dunham, J. R.; Pierce, J. L.

    1986-01-01

    The results of a laboratory experiment in flight control software reliability are reported. The experiment tests a small sample of implementations of a pitch axis control law for a PA28 aircraft with over 14 million pitch commands with varying levels of additive input and feedback noise. The testing which uses the method of n-version programming for error detection surfaced four software faults in one implementation of the control law. The small number of detected faults precluded the conduct of the error burst analyses. The pitch axis problem provides data for use in constructing a model in the prediction of the reliability of software in systems with feedback. The study is undertaken to find means to perform reliability evaluations of flight control software.

  9. 77 FR 39385 - Receipts-Based, Small Business Size Standard

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-07-03

    ... Business Size Standard AGENCY: Nuclear Regulatory Commission. ACTION: Direct final rule. SUMMARY: The U.S.... The NRC is increasing its receipts-based, small business size standard from $6.5 million to $7 million to conform to the standard set by the Small Business Administration (SBA). This size standard...

  10. Accuracy of endoscopic intraoperative assessment of urologic stone size.

    PubMed

    Patel, Nishant; Chew, Ben; Knudsen, Bodo; Lipkin, Michael; Wenzler, David; Sur, Roger L

    2014-05-01

    Endoscopic treatment of renal calculi relies on surgeon assessment of residual stone fragment size for either basket removal or for the passage of fragments postoperatively. We therefore sought to determine the accuracy of endoscopic assessment of renal calculi size. Between January and May 2013, five board-certified endourologists participated in an ex vivo artificial endoscopic simulation. A total of 10 stones (pebbles) were measured (mm) by nonparticipating urologist (N.D.P.) with electronic calibers and placed into separate labeled opaque test tubes to prevent visualization of the stones through the side of the tube. Endourologists were blinded to the actual size of the stones. A flexible digital ureteroscope with a 200-μm core sized laser fiber in the working channel as a size reference was placed through the ureteroscope into the test tube to estimate the stone size (mm). Accuracy was determined by obtaining the correlation coefficient (r) and constructing an Altman-Bland plot. Endourologists tended to overestimate actual stone size by a margin of 0.05 mm. The Pearson correlation coefficient was r=0.924, with a p-value<0.01. The estimation of small stones (<4 mm) had a greater accuracy than large stones (≥4 mm), r=0.911 vs r=0.666. Altman-bland plot analysis suggests that surgeons are able to accurately estimate stone size within a range of -1.8 to +1.9 mm. This ex vivo simulation study demonstrates that endoscopic assessment is reliable when assessing stone size. On average, there was a slight tendency to overestimate stone size by 0.05 mm. Most endourologists could visually estimate stone size within 2 mm of the actual size. These findings could be generalized to state that endourologists are accurately able to intraoperatively assess residual stone fragment size to guide decision making.

  11. 13 CFR 121.411 - What are the size procedures for SBA's Section 8(d) Subcontracting Program?

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... SMALL BUSINESS ADMINISTRATION SMALL BUSINESS SIZE REGULATIONS Size Eligibility Provisions and Standards... maintaining a small business source list. Even though a concern is on a small business source list, it must still qualify and self-certify as a small business at the time it submits its offer as a section 8(d...

  12. 13 CFR 121.411 - What are the size procedures for SBA's Section 8(d) Subcontracting Program?

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... SMALL BUSINESS ADMINISTRATION SMALL BUSINESS SIZE REGULATIONS Size Eligibility Provisions and Standards... maintaining a small business source list. Even though a concern is on a small business source list, it must still qualify and self-certify as a small business at the time it submits its offer as a section 8(d...

  13. 13 CFR 121.411 - What are the size procedures for SBA's Section 8(d) Subcontracting Program?

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... SMALL BUSINESS ADMINISTRATION SMALL BUSINESS SIZE REGULATIONS Size Eligibility Provisions and Standards... maintaining a small business source list. Even though a concern is on a small business source list, it must still qualify and self-certify as a small business at the time it submits its offer as a section 8(d...

  14. Structure reliability design and analysis of support ring for cylinder seal

    NASA Astrophysics Data System (ADS)

    Minmin, Zhao

    2017-09-01

    In this paper, the general reliability design process of the cross-sectional dimension of the support ring is introduced, which is used for the cylinder sealing. Then, taking a certain section shape support ring as an example, the every size parameters of section are determined from the view point of reliability design. Last, the static strength and reliability of the support ring are analyzed to verify the correctness of the reliability design result.

  15. 48 CFR 19.302 - Protesting a small business representation or rerepresentation.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... FEDERAL ACQUISITION REGULATION SOCIOECONOMIC PROGRAMS SMALL BUSINESS PROGRAMS Determination of Small Business Status for Small Business Programs 19.302 Protesting a small business representation or rerepresentation. (a)(1) The Small Business Administration (SBA) regulations on small business size and size...

  16. Paleoenvironmental evidence for first human colonization of the eastern Caribbean

    NASA Astrophysics Data System (ADS)

    Siegel, Peter E.; Jones, John G.; Pearsall, Deborah M.; Dunning, Nicholas P.; Farrell, Pat; Duncan, Neil A.; Curtis, Jason H.; Singh, Sushant K.

    2015-12-01

    Identifying and dating first human colonization of new places is challenging, especially when group sizes were small and material traces of their occupations were ephemeral. Generating reliable reconstructions of human colonization patterns from intact archaeological sites may be difficult to impossible given post-depositional taphonomic processes and in cases of island and coastal locations the inundation of landscapes resulting from post-Pleistocene sea-level rise. Paleoenvironmental reconstruction is proving to be a more reliable method of identifying small-scale human colonization events than archaeological data alone. We demonstrate the method through a sediment-coring project across the Lesser Antilles and southern Caribbean. Paleoenvironmental data were collected informing on the timing of multiple island-colonization events and land-use histories spanning the full range of human occupations in the Caribbean, from the initial forays into the islands through the arrival and eventual domination of the landscapes and indigenous people by Europeans. In some areas, our data complement archaeological, paleoecological, and historical findings from the Lesser Antilles and in others amplify understanding of colonization history. Here, we highlight data relating to the timing and process of initial colonization in the eastern Caribbean. In particular, paleoenvironmental data from Trinidad, Grenada, Martinique, and Marie-Galante (Guadeloupe) provide a basis for revisiting initial colonization models of the Caribbean. We conclude that archaeological programs addressing human occupations dating to the early to mid-Holocene, especially in dynamic coastal settings, should systematically incorporate paleoenvironmental investigations.

  17. Sensitivity Analysis of ProSEDS (Propulsive Small Expendable Deployer System) Data Communication System

    NASA Technical Reports Server (NTRS)

    Park, Nohpill; Reagan, Shawn; Franks, Greg; Jones, William G.

    1999-01-01

    This paper discusses analytical approaches to evaluating performance of Spacecraft On-Board Computing systems, thereby ultimately achieving a reliable spacecraft data communications systems. The sensitivity analysis approach of memory system on the ProSEDS (Propulsive Small Expendable Deployer System) as a part of its data communication system will be investigated. Also, general issues and possible approaches to reliable Spacecraft On-Board Interconnection Network and Processor Array will be shown. The performance issues of a spacecraft on-board computing systems such as sensitivity, throughput, delay and reliability will be introduced and discussed.

  18. 40 CFR 428.50 - Applicability; description of the small-sized general molded, extruded, and fabricated rubber...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... RUBBER MANUFACTURING POINT SOURCE CATEGORY Small-Sized General Molded, Extruded, and Fabricated Rubber..., foam rubber backing, rubber cement-dipped goods, and retreaded tires by small-sized plants...

  19. [Study of the reliability in one dimensional size measurement with digital slit lamp microscope].

    PubMed

    Wang, Tao; Qi, Chaoxiu; Li, Qigen; Dong, Lijie; Yang, Jiezheng

    2010-11-01

    To study the reliability of digital slit lamp microscope as a tool for quantitative analysis in one dimensional size measurement. Three single-blinded observers acquired and repeatedly measured the images with a size of 4.00 mm and 10.00 mm on the vernier caliper, which simulatated the human eye pupil and cornea diameter under China-made digital slit lamp microscope in the objective magnification of 4 times, 10 times, 16 times, 25 times, 40 times and 4 times, 10 times, 16 times, respectively. The correctness and precision of measurement were compared. The images with 4 mm size were measured by three investigators and the average values were located between 3.98 to 4.06. For the images with 10.00 mm size, the average values fell within 10.00 ~ 10.04. Measurement results of 4.00 mm images showed, except A4, B25, C16 and C25, significant difference was noted between the measured value and the true value. Regarding measurement results of 10.00 mm iamges indicated, except A10, statistical significance was found between the measured value and the true value. In terms of comparing the results of the same size measured at different magnifications by the same investigator, except for investigators A's measurements of 10.00 mm dimension, the measurement results by all the remaining investigators presented statistical significance at different magnifications. Compared measurements of the same size with different magnifications, measurements of 4.00 mm in 4-fold magnification had no significant difference among the investigators', the remaining results were statistically significant. The coefficient of variation of all measurement results were less than 5%; as magnification increased, the coefficient of variation decreased. The measurement of digital slit lamp microscope in one-dimensional size has good reliability,and should be performed for reliability analysis before used for quantitative analysis to reduce systematic errors.

  20. A Cost-effective and Reliable Method to Predict Mechanical Stress in Single-use and Standard Pumps

    PubMed Central

    Dittler, Ina; Dornfeld, Wolfgang; Schöb, Reto; Cocke, Jared; Rojahn, Jürgen; Kraume, Matthias; Eibl, Dieter

    2015-01-01

    Pumps are mainly used when transferring sterile culture broths in biopharmaceutical and biotechnological production processes. However, during the pumping process shear forces occur which can lead to qualitative and/or quantitative product loss. To calculate the mechanical stress with limited experimental expense, an oil-water emulsion system was used, whose suitability was demonstrated for drop size detections in bioreactors1. As drop breakup of the oil-water emulsion system is a function of mechanical stress, drop sizes need to be counted over the experimental time of shear stress investigations. In previous studies, the inline endoscopy has been shown to be an accurate and reliable measurement technique for drop size detections in liquid/liquid dispersions. The aim of this protocol is to show the suitability of the inline endoscopy technique for drop size measurements in pumping processes. In order to express the drop size, the Sauter mean diameter d32 was used as the representative diameter of drops in the oil-water emulsion. The results showed low variation in the Sauter mean diameters, which were quantified by standard deviations of below 15%, indicating the reliability of the measurement technique. PMID:26274765

  1. Microfilament-Eruption Mechanism for Solar Spicules

    NASA Technical Reports Server (NTRS)

    Sterling, Alphonse C.; Moore, Ronald L.

    2017-01-01

    Recent studies indicate that solar coronal jets result from eruption of small-scale filaments, or "minifilaments" (Sterling et al. 2015, Nature, 523, 437; Panesar et al. ApJL, 832L, 7). In many aspects, these coronal jets appear to be small-scale versions of long-recognized large-scale solar eruptions that are often accompanied by eruption of a large-scale filament and that produce solar flares and coronal mass ejections (CMEs). In coronal jets, a jet-base bright point (JBP) that is often observed to accompany the jet and that sits on the magnetic neutral line from which the minifilament erupts, corresponds to the solar flare of larger-scale eruptions that occurs at the neutral line from which the large-scale filament erupts. Large-scale eruptions are relatively uncommon (approximately 1 per day) and occur with relatively large-scale erupting filaments (approximately 10 (sup 5) kilometers long). Coronal jets are more common (approximately 100s per day), but occur from erupting minifilaments of smaller size (approximately 10 (sup 4) kilometers long). It is known that solar spicules are much more frequent (many millions per day) than coronal jets. Just as coronal jets are small-scale versions of large-scale eruptions, here we suggest that solar spicules might in turn be small-scale versions of coronal jets; we postulate that the spicules are produced by eruptions of "microfilaments" of length comparable to the width of observed spicules (approximately 300 kilometers). A plot of the estimated number of the three respective phenomena (flares/CMEs, coronal jets, and spicules) occurring on the Sun at a given time, against the average sizes of erupting filaments, minifilaments, and the putative microfilaments, results in a size distribution that can be fitted with a power-law within the estimated uncertainties. The counterparts of the flares of large-scale eruptions and the JBPs of jets might be weak, pervasive, transient brightenings observed in Hinode/CaII images, and the production of spicules by microfilament eruptions might explain why spicules spin, as do coronal jets. The expected small-scale neutral lines from which the microfilaments would be expected to erupt would be difficult to detect reliably with current instrumentation, but might be apparent with instrumentation of the near future. A full report on this work appears in Sterling and Moore 2016, ApJL, 829, L9.

  2. Nearest neighbor density ratio estimation for large-scale applications in astronomy

    NASA Astrophysics Data System (ADS)

    Kremer, J.; Gieseke, F.; Steenstrup Pedersen, K.; Igel, C.

    2015-09-01

    In astronomical applications of machine learning, the distribution of objects used for building a model is often different from the distribution of the objects the model is later applied to. This is known as sample selection bias, which is a major challenge for statistical inference as one can no longer assume that the labeled training data are representative. To address this issue, one can re-weight the labeled training patterns to match the distribution of unlabeled data that are available already in the training phase. There are many examples in practice where this strategy yielded good results, but estimating the weights reliably from a finite sample is challenging. We consider an efficient nearest neighbor density ratio estimator that can exploit large samples to increase the accuracy of the weight estimates. To solve the problem of choosing the right neighborhood size, we propose to use cross-validation on a model selection criterion that is unbiased under covariate shift. The resulting algorithm is our method of choice for density ratio estimation when the feature space dimensionality is small and sample sizes are large. The approach is simple and, because of the model selection, robust. We empirically find that it is on a par with established kernel-based methods on relatively small regression benchmark datasets. However, when applied to large-scale photometric redshift estimation, our approach outperforms the state-of-the-art.

  3. Disturbance size and severity covary in small and mid-size wind disturbances in Pennsylvania northern hardwoods forests

    Treesearch

    Chris J. Peterson; Lisa M. Krueger; Alejandro A. Royo; Scott Stark; Walter P. Carson

    2013-01-01

    Do large disturbances differ from small ones in characteristics other than size? The importance of disturbances in forest dynamics is unquestioned, and the size of the disturbed area (size of gap) is the most common way of differentiating disturbances. But few studies have examined other disturbance characteristics to see if small and large disturbances are different....

  4. SearchSmallRNA: a graphical interface tool for the assemblage of viral genomes using small RNA libraries data.

    PubMed

    de Andrade, Roberto R S; Vaslin, Maite F S

    2014-03-07

    Next-generation parallel sequencing (NGS) allows the identification of viral pathogens by sequencing the small RNAs of infected hosts. Thus, viral genomes may be assembled from host immune response products without prior virus enrichment, amplification or purification. However, mapping of the vast information obtained presents a bioinformatics challenge. In order to by pass the need of line command and basic bioinformatics knowledge, we develop a mapping software with a graphical interface to the assemblage of viral genomes from small RNA dataset obtained by NGS. SearchSmallRNA was developed in JAVA language version 7 using NetBeans IDE 7.1 software. The program also allows the analysis of the viral small interfering RNAs (vsRNAs) profile; providing an overview of the size distribution and other features of the vsRNAs produced in infected cells. The program performs comparisons between each read sequenced present in a library and a chosen reference genome. Reads showing Hamming distances smaller or equal to an allowed mismatched will be selected as positives and used to the assemblage of a long nucleotide genome sequence. In order to validate the software, distinct analysis using NGS dataset obtained from HIV and two plant viruses were used to reconstruct viral whole genomes. SearchSmallRNA program was able to reconstructed viral genomes using NGS of small RNA dataset with high degree of reliability so it will be a valuable tool for viruses sequencing and discovery. It is accessible and free to all research communities and has the advantage to have an easy-to-use graphical interface. SearchSmallRNA was written in Java and is freely available at http://www.microbiologia.ufrj.br/ssrna/.

  5. SearchSmallRNA: a graphical interface tool for the assemblage of viral genomes using small RNA libraries data

    PubMed Central

    2014-01-01

    Background Next-generation parallel sequencing (NGS) allows the identification of viral pathogens by sequencing the small RNAs of infected hosts. Thus, viral genomes may be assembled from host immune response products without prior virus enrichment, amplification or purification. However, mapping of the vast information obtained presents a bioinformatics challenge. Methods In order to by pass the need of line command and basic bioinformatics knowledge, we develop a mapping software with a graphical interface to the assemblage of viral genomes from small RNA dataset obtained by NGS. SearchSmallRNA was developed in JAVA language version 7 using NetBeans IDE 7.1 software. The program also allows the analysis of the viral small interfering RNAs (vsRNAs) profile; providing an overview of the size distribution and other features of the vsRNAs produced in infected cells. Results The program performs comparisons between each read sequenced present in a library and a chosen reference genome. Reads showing Hamming distances smaller or equal to an allowed mismatched will be selected as positives and used to the assemblage of a long nucleotide genome sequence. In order to validate the software, distinct analysis using NGS dataset obtained from HIV and two plant viruses were used to reconstruct viral whole genomes. Conclusions SearchSmallRNA program was able to reconstructed viral genomes using NGS of small RNA dataset with high degree of reliability so it will be a valuable tool for viruses sequencing and discovery. It is accessible and free to all research communities and has the advantage to have an easy-to-use graphical interface. Availability and implementation SearchSmallRNA was written in Java and is freely available at http://www.microbiologia.ufrj.br/ssrna/. PMID:24607237

  6. 77 FR 56253 - Ninth Meeting: RTCA Special Committee 225, Rechargeable Lithium Battery and Battery Systems-Small...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-09-12

    ... 225, Rechargeable Lithium Battery and Battery Systems--Small and Medium Size AGENCY: Federal Aviation... 225, Rechargeable Lithium Battery and Battery Systems--Small and Medium Size. SUMMARY: The FAA is..., Rechargeable Lithium Battery and Battery Systems--Small and Medium Size. DATES: The meeting will be held...

  7. 77 FR 66084 - Tenth Meeting: RTCA Special Committee 225, Rechargeable Lithium Battery and Battery Systems-Small...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-11-01

    ... 225, Rechargeable Lithium Battery and Battery Systems--Small and Medium Size AGENCY: Federal Aviation... 225, Rechargeable Lithium Battery and Battery Systems--Small and Medium Size. SUMMARY: The FAA is..., Rechargeable Lithium Battery and Battery Systems--Small and Medium Size. DATES: The meeting will be held...

  8. Navy applications experience with small wind power systems

    NASA Astrophysics Data System (ADS)

    Pal, D.

    1985-05-01

    This report describes the experience gained and lesson learned from the ongoing field evaluations of seven small, 2-to 20-kW wind energy conversion systems (WECS) at Navy installations located in the Southern California desert, on San Nicolas Island, in California, and in Kaneohe Bay, Hawaii. The field tests show that the WECS's bearings and yaw slip-rings are prone to failure. The failures were attributed to the corrosive environment and poor design practices. Based upon the field tests, it is concluded that a reliable WECS must use a permanent magnet alternator without a gearbox and yaw slip-rings that are driven by a fixed pitch wind turbine rotor. The present state-of-the-art in small WECS technology, including environmental concerns, is reviewed. Also presented is how the technology is advancing to improve reliability and availability for effectively using wind power at Navy bases. The field evaluations are continuing on the small WECS in order to develop operation, maintenance, and reliability data.

  9. Thermophysical modeling of main-belt asteroids from WISE thermal data

    NASA Astrophysics Data System (ADS)

    Hanuš, J.; Delbo', M.; Ďurech, J.; Alí-Lagoa, V.

    2018-07-01

    By means of a varied-shape thermophysical model of Hanuš et al. (2015) that takes into account asteroid shape and pole uncertainties, we analyze the thermal infrared data acquired by the NASA's Wide-field Infrared Survey Explorer of about 300 asteroids with derived convex shape models. We utilize publicly available convex shape models and rotation states as input for the thermophysical modeling. For more than one hundred asteroids, the thermophysical modeling gives us an acceptable fit to the thermal infrared data allowing us to report their thermophysical properties such as size, thermal inertia, surface roughness or visible geometric albedo. This work more than doubles the number of asteroids with determined thermophysical properties, especially the thermal inertia. In the remaining cases, the shape model and pole orientation uncertainties, specific rotation or thermophysical properties, poor thermal infrared data or their coverage prevent the determination of reliable thermophysical properties. Finally, we present the main results of the statistical study of derived thermophysical parameters within the whole population of main-belt asteroids and within few asteroid families. Our sizes based on TPM are, in average, consistent with the radiometric sizes reported by Mainzer et al. (2016). The thermal inertia increases with decreasing size, but a large range of thermal inertia values is observed within the similar size ranges between D ∼ 10-100 km. We derived unexpectedly low thermal inertias ( < 20 J m-2 s- 1 / 2 K-1) for several asteroids with sizes 10 < D < 50 km, indicating a very fine and mature regolith on these small bodies. The thermal inertia values seem to be consistent within several collisional families, however, the statistical sample is in all cases rather small. The fast rotators with rotation period P ≲ 4 h tend to have slightly larger thermal inertia values, so probably do not have a fine regolith on the surface. This could be explained, for example, by the loss of the fine regolith due to the centrifugal force, or by the ineffectiveness of the regolith production(e.g., by the thermal cracking mechanism of Delbo' et al. 2014).

  10. Detecting spatial structures in throughfall data: the effect of extent, sample size, sampling design, and variogram estimation method

    NASA Astrophysics Data System (ADS)

    Voss, Sebastian; Zimmermann, Beate; Zimmermann, Alexander

    2016-04-01

    In the last three decades, an increasing number of studies analyzed spatial patterns in throughfall to investigate the consequences of rainfall redistribution for biogeochemical and hydrological processes in forests. In the majority of cases, variograms were used to characterize the spatial properties of the throughfall data. The estimation of the variogram from sample data requires an appropriate sampling scheme: most importantly, a large sample and an appropriate layout of sampling locations that often has to serve both variogram estimation and geostatistical prediction. While some recommendations on these aspects exist, they focus on Gaussian data and high ratios of the variogram range to the extent of the study area. However, many hydrological data, and throughfall data in particular, do not follow a Gaussian distribution. In this study, we examined the effect of extent, sample size, sampling design, and calculation methods on variogram estimation of throughfall data. For our investigation, we first generated non-Gaussian random fields based on throughfall data with heavy outliers. Subsequently, we sampled the fields with three extents (plots with edge lengths of 25 m, 50 m, and 100 m), four common sampling designs (two grid-based layouts, transect and random sampling), and five sample sizes (50, 100, 150, 200, 400). We then estimated the variogram parameters by method-of-moments and residual maximum likelihood. Our key findings are threefold. First, the choice of the extent has a substantial influence on the estimation of the variogram. A comparatively small ratio of the extent to the correlation length is beneficial for variogram estimation. Second, a combination of a minimum sample size of 150, a design that ensures the sampling of small distances and variogram estimation by residual maximum likelihood offers a good compromise between accuracy and efficiency. Third, studies relying on method-of-moments based variogram estimation may have to employ at least 200 sampling points for reliable variogram estimates. These suggested sample sizes exceed the numbers recommended by studies dealing with Gaussian data by up to 100 %. Given that most previous throughfall studies relied on method-of-moments variogram estimation and sample sizes << 200, our current knowledge about throughfall spatial variability stands on shaky ground.

  11. Detecting spatial structures in throughfall data: The effect of extent, sample size, sampling design, and variogram estimation method

    NASA Astrophysics Data System (ADS)

    Voss, Sebastian; Zimmermann, Beate; Zimmermann, Alexander

    2016-09-01

    In the last decades, an increasing number of studies analyzed spatial patterns in throughfall by means of variograms. The estimation of the variogram from sample data requires an appropriate sampling scheme: most importantly, a large sample and a layout of sampling locations that often has to serve both variogram estimation and geostatistical prediction. While some recommendations on these aspects exist, they focus on Gaussian data and high ratios of the variogram range to the extent of the study area. However, many hydrological data, and throughfall data in particular, do not follow a Gaussian distribution. In this study, we examined the effect of extent, sample size, sampling design, and calculation method on variogram estimation of throughfall data. For our investigation, we first generated non-Gaussian random fields based on throughfall data with large outliers. Subsequently, we sampled the fields with three extents (plots with edge lengths of 25 m, 50 m, and 100 m), four common sampling designs (two grid-based layouts, transect and random sampling) and five sample sizes (50, 100, 150, 200, 400). We then estimated the variogram parameters by method-of-moments (non-robust and robust estimators) and residual maximum likelihood. Our key findings are threefold. First, the choice of the extent has a substantial influence on the estimation of the variogram. A comparatively small ratio of the extent to the correlation length is beneficial for variogram estimation. Second, a combination of a minimum sample size of 150, a design that ensures the sampling of small distances and variogram estimation by residual maximum likelihood offers a good compromise between accuracy and efficiency. Third, studies relying on method-of-moments based variogram estimation may have to employ at least 200 sampling points for reliable variogram estimates. These suggested sample sizes exceed the number recommended by studies dealing with Gaussian data by up to 100 %. Given that most previous throughfall studies relied on method-of-moments variogram estimation and sample sizes ≪200, currently available data are prone to large uncertainties.

  12. How to Measure the Onset of Babbling Reliably?

    ERIC Educational Resources Information Center

    Molemans, Inge; van den Berg, Renate; van Severen, Lieve; Gillis, Steven

    2012-01-01

    Various measures for identifying the onset of babbling have been proposed in the literature, but a formal definition of the exact procedure and a thorough validation of the sample size required for reliably establishing babbling onset is lacking. In this paper the reliability of five commonly used measures is assessed using a large longitudinal…

  13. High-performance and high-reliability SOT-6 packaged diplexer based on advanced IPD fabrication techniques

    NASA Astrophysics Data System (ADS)

    Qiang, Tian; Wang, Cong; Kim, Nam-Young

    2017-08-01

    A diplexer offering the advantages of compact size, high performance, and high reliability is proposed on the basis of advanced integrated passive device (IPD) fabrication techniques. The proposed diplexer is developed by combining a third-order low-pass filter (LPF) and a third-order high-pass filter (HPF), which are designed on the basis of the elliptic function prototype low-pass filter. Primary components, such as inductors and capacitors, are designed and fabricated with high Q-factor and appropriate values, and they are subsequently used to construct a compact diplexer having a chip area of 900 μm × 1100 μm (0.009 λ0 × 0.011 λ0, where λ0 is the guided wavelength). In addition, a small-outline transistor (SOT-6) packaging method is adopted, and reliability tests (including temperature, humidity, vibration, and pressure) are conducted to guarantee long-term stability and commercial success. The packaged measurement results indicate excellent RF performance with insertion losses of 1.39 dB and 0.75 dB at operation bands of 0.9 GHz and 1.8 GHz, respectively. The return loss is lower than 10 dB from 0.5 GHz to 4.0 GHz, while the isolation is higher than 15 dB from 0.5 GHz to 3.0 GHz. Thus, it can be concluded that the proposed SOT-6 packaged diplexer is a promising candidate for GSM/CDMA applications. Synthetic solution of diplexer design, RF performance optimization, fabrication process, packaging, RF response measurement, and reliability test is particularly explained and analyzed in this work.

  14. Cygnus Performance in Subcritical Experiments

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    G. Corrow, M. Hansen, D. Henderson, S. Lutz, C. Mitton, et al.

    2008-02-01

    The Cygnus Dual Beam Radiographic Facility consists of two identical radiographic sources with the following specifications: 4-rad dose at 1 m, 1-mm spot size, 50-ns pulse length, 2.25-MeV endpoint energy. The facility is located in an underground tunnel complex at the Nevada Test Site. Here SubCritical Experiments (SCEs) are performed to study the dynamic properties of plutonium. The Cygnus sources were developed as a primary diagnostic for these tests. Since SCEs are single-shot, high-value events - reliability and reproducibility are key issues. Enhanced reliability involves minimization of failure modes through design, inspection, and testing. Many unique hardware and operational featuresmore » were incorporated into Cygnus to insure reliability. Enhanced reproducibility involves normalization of shot-to-shot output also through design, inspection, and testing. The first SCE to utilize Cygnus, Armando, was executed on May 25, 2004. A year later, April - May 2005, calibrations using a plutonium step wedge were performed. The results from this series were used for more precise interpretation of the Armando data. In the period February - May 2007 Cygnus was fielded on Thermos, which is a series of small-sample plutonium shots using a one-dimensional geometry. Pulsed power research generally dictates frequent change in hardware configuration. Conversely, SCE applications have typically required constant machine settings. Therefore, while operating during the past four years we have accumulated a large database for evaluation of machine performance under highly consistent operating conditions. Through analysis of this database Cygnus reliability and reproducibility on Armando, Step Wedge, and Thermos is presented.« less

  15. [Formula: see text]Interpreting change on the neurobehavioral symptom inventory and the PTSD checklist in military personnel.

    PubMed

    Belanger, Heather G; Lange, Rael T; Bailie, Jason; Iverson, Grant L; Arrieux, Jacques P; Ivins, Brian J; Cole, Wesley R

    2016-10-01

    The purpose of this study was to examine the prevalence and stability of symptom reporting in a healthy military sample and to develop reliable change indices for two commonly used self-report measures in the military health care system. Participants were 215 U.S. active duty service members recruited from Fort Bragg, NC as normal controls as part of a larger study. Participants completed the Neurobehavioral Symptom Inventory (NSI) and Posttraumatic Checklist (PCL) twice, separated by approximately 30 days. Depending on the endorsement level used (i.e. ratings of 'mild' or greater vs. ratings of 'moderate' or greater), approximately 2-15% of this sample met DSM-IV symptom criteria for Postconcussional Disorder across time points, while 1-6% met DSM-IV symptom criteria for Posttraumatic Stress Disorder. Effect sizes for change from Time 1 to Time 2 on individual symptoms were small (Cohen's d = .01 to .13). The test-retest reliability for the NSI total score was r = .78 and the PCL score was r = .70. An eight-point change in symptom reporting represented reliable change on the NSI total score, with a seven-point change needed on the PCL. Postconcussion-like symptoms are not unique to mild TBI and are commonly reported in a healthy soldier sample. It is important for clinicians to use normative data when evaluating a service member or veteran and when evaluating the likelihood that a change in symptom reporting is reliable and clinically meaningful.

  16. Accurate Size and Size-Distribution Determination of Polystyrene Latex Nanoparticles in Aqueous Medium Using Dynamic Light Scattering and Asymmetrical Flow Field Flow Fractionation with Multi-Angle Light Scattering

    PubMed Central

    Kato, Haruhisa; Nakamura, Ayako; Takahashi, Kayori; Kinugasa, Shinichi

    2012-01-01

    Accurate determination of the intensity-average diameter of polystyrene latex (PS-latex) by dynamic light scattering (DLS) was carried out through extrapolation of both the concentration of PS-latex and the observed scattering angle. Intensity-average diameter and size distribution were reliably determined by asymmetric flow field flow fractionation (AFFFF) using multi-angle light scattering (MALS) with consideration of band broadening in AFFFF separation. The intensity-average diameter determined by DLS and AFFFF-MALS agreed well within the estimated uncertainties, although the size distribution of PS-latex determined by DLS was less reliable in comparison with that determined by AFFFF-MALS. PMID:28348293

  17. Reduced fecundity in small populations of the rare plant Gentianopsis ciliate (Gentianaceae)

    USGS Publications Warehouse

    Kery, M.; Matthies, D.

    2004-01-01

    Habitat destruction is the main cause for the biodiversity crisis. Surviving populations are often fragmented, i.e., small and isolated from each other. Reproduction of plants in small populations is often reduced, and this has been attributed to inbreeding depression, reduced attractiveness for pollinators, and reduced habitat quality in small populations. Here we present data on the effects of fragmentation on the rare, self-compatible perennial herb Gentianopsis ciliata (Gentianaceae), a species with very small and presumably well-dispersed seeds. We studied the relationship between population size, plant size, and the number of flowers produced in 63 populations from 1996-1998. In one of the years, leaf and flower size and the number of seeds produced per fruit was studied in a subset of 25 populations. Plant size, flower size, and the number of seeds per fruit and per plant increased with population size, whereas leaf length and the number of flowers per plant did not. The effects of population size on reproduction and on flower size remained significant if the effects were adjusted for differences in plant size, indicating that they could not be explained by differences in habitat quality. The strongly reduced reproduction in small populations may be due to pollination limitation, while the reduced flower size could indicate genetic effects.

  18. Reduced fecundity in small populations of the rare plant Gentianopsis ciliate (Gentianaceae)

    USGS Publications Warehouse

    Robbins, C.S.

    1983-01-01

    Habitat destruction is the main cause for the biodiversity crisis. Surviving populations are often fragmented, i.e., small and isolated from each other. Reproduction of plants in small populations is often reduced, and this has been attributed to inbreeding depression, reduced attractiveness for pollinators, and reduced habitat quality in small populations. Here we present data on the effects of fragmentation on the rare, self-compatible perennial herb Gentianopsis ciliata (Gentianaceae), a species with very small and presumably well-dispersed seeds. We studied the relationship between population size, plant size, and the number of flowers produced in 63 populations from 1996-1998. In one of the years, leaf and flower size and the number of seeds produced per fruit was studied in a subset of 25 populations. Plant size, flower size, and the number of seeds per fruit and per plant increased with population size, whereas leaf length and the number of flowers per plant did not. The effects of population size on reproduction and on flower size remained significant if the effects were adjusted for differences in plant size, indicating that they could not be explained by differences in habitat quality. The strongly reduced reproduction in small populations may be due to pollination limitation, while the reduced flower size could indicate genetic effects.

  19. Hail Monitor Sensor

    NASA Technical Reports Server (NTRS)

    Younquist, Robert; Haskell, William; Immer, Christopher; Cox, Bobby; Lane, John

    2009-01-01

    An inexpensive and simple hail monitor design has been developed that has a single piezoelectric ceramic disc and uses a metal plate as a sounding board. The structure is durable and able to withstand the launch environment. This design has several advantages over a multi-ceramic sensor, including reduced cost and complexity, increased durability, and improvement in impact response uniformity over the active surface. However, the most important characteristic of this design is the potential to use frequency discrimination between the spectrum created from raindrop impact and a hailstone impact. The sound of hail hitting a metal plate is distinctly different from the sound of rain hitting the same plate. This fortuitous behavior of the pyramid sensor may lead to a signal processing strategy, which is inherently more reliable than one depending on amplitude processing only. The initial concept has been im proved by forming a shallow pyramid structure so that hail is encouraged to bounce away from the sensor so as not to be counted more than once. The sloped surface also discourages water from collecting. Additionally, the final prototype version includes a mounting box for the piezo-ceramic, which is offset from the pyramid apex, thus helping to reduce non-uniform response (see Figure 2). The frequency spectra from a single raindrop impact and a single ice ball impact have been compared. The most notable feature of the frequency resonant peaks is the ratio of the 5.2 kHz to 3.1 kHz components. In the case of a raindrop, this ratio is very small. But in the case of an ice ball, the ratio is roughly one third. This frequency signature of ice balls should provide a robust method for discriminating raindrops from hailstones. Considering that hail size distributions (HSDs) and fall rates are roughly 1 percent that of rainfall, hailstone sizes range from a few tenths of a centimeter to several centimeters. There may be considerable size overlap between large rain and small hail. As hail occurs infrequently at KSC, the ideal HSD measurement sensor needs to have a collection area roughly 100 times greater than a raindrop-size distribution sensor or disdrometer. The sensitivity should be such that it can detect and count very small hail in the midst of intense rainfall consisting of large raindrop sizes. The dynamic range and durability should allow measurement of the largest hail sizes, and the operation and calibration strategy should consider the infrequent occurrence of hail fall over the KSC area.

  20. 13 CFR 121.903 - How may an agency use size standards for its programs that are different than those established...

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... suitable for their programs, then agency heads may establish a more appropriate small business definition... 13 Business Credit and Assistance 1 2010-01-01 2010-01-01 false How may an agency use size... Business Credit and Assistance SMALL BUSINESS ADMINISTRATION SMALL BUSINESS SIZE REGULATIONS Size...

  1. Are Small Schools Better? School Size Considerations for Safety & Learning. Policy Brief.

    ERIC Educational Resources Information Center

    McRobbie, Joan

    New studies from the 1990s have strengthened an already notable consensus on school size: smaller is better. This policy brief outlines research findings on why size makes a difference, how small is small enough, effective approaches to downsizing, and key barriers. No agreement exists at present on optimal school size, but research suggests a…

  2. Interdependent effects of male and female body size plasticity on mating behaviour of predatory mites.

    PubMed

    Walzer, Andreas; Schausberger, Peter

    2015-02-01

    The adaptive canalization hypothesis predicts that traits with low phenotypic plasticity are more fitness relevant, because they have been canalized via strong past selection, than traits with high phenotypic plasticity. Based on differing male body size plasticities of the predatory mites Phytoseiulus persimilis (low plasticity) and Neoseiulus californicus (high plasticity), we accordingly hypothesized that small male body size entails higher costs in female choice and male-male competition in P. persimilis than N. californicus . Males of both species are highly polygynous but females differ in the level of polyandry (low level in P. persimilis ; medium level in N. californicus ). We videotaped the mating interactions in triplets of either P. persimilis or N. californicus , consisting of a virgin female (small or standard-sized) and a small and a standard-sized male. Mating by both small and standard-sized P. persimilis females was biased towards standard-sized males, resulting from the interplay between female preference for standard-sized males and the inferiority of small males in male-male competition. In contrast, mating by N. californicus females was equally balanced between small and standard-sized males. Small N. californicus males were more aggressive ('Napoleon complex') in male-male competition, reducing the likelihood of encounter between the standard-sized male and the female, and thus counterbalancing female preference for standard-sized males. Our results support the hypothesis that male body size is more important to fitness in the low-level polyandrous P. persimilis than in the medium-level polyandrous N. californicus and provide a key example of the implications of sexually selected body size plasticity on mating behaviour.

  3. Interdependent effects of male and female body size plasticity on mating behaviour of predatory mites

    PubMed Central

    Walzer, Andreas; Schausberger, Peter

    2015-01-01

    The adaptive canalization hypothesis predicts that traits with low phenotypic plasticity are more fitness relevant, because they have been canalized via strong past selection, than traits with high phenotypic plasticity. Based on differing male body size plasticities of the predatory mites Phytoseiulus persimilis (low plasticity) and Neoseiulus californicus (high plasticity), we accordingly hypothesized that small male body size entails higher costs in female choice and male–male competition in P. persimilis than N. californicus. Males of both species are highly polygynous but females differ in the level of polyandry (low level in P. persimilis; medium level in N. californicus). We videotaped the mating interactions in triplets of either P. persimilis or N. californicus, consisting of a virgin female (small or standard-sized) and a small and a standard-sized male. Mating by both small and standard-sized P. persimilis females was biased towards standard-sized males, resulting from the interplay between female preference for standard-sized males and the inferiority of small males in male–male competition. In contrast, mating by N. californicus females was equally balanced between small and standard-sized males. Small N. californicus males were more aggressive (‘Napoleon complex’) in male–male competition, reducing the likelihood of encounter between the standard-sized male and the female, and thus counterbalancing female preference for standard-sized males. Our results support the hypothesis that male body size is more important to fitness in the low-level polyandrous P. persimilis than in the medium-level polyandrous N. californicus and provide a key example of the implications of sexually selected body size plasticity on mating behaviour. PMID:25673881

  4. The (un)reliability of item-level semantic priming effects.

    PubMed

    Heyman, Tom; Bruninx, Anke; Hutchison, Keith A; Storms, Gert

    2018-04-05

    Many researchers have tried to predict semantic priming effects using a myriad of variables (e.g., prime-target associative strength or co-occurrence frequency). The idea is that relatedness varies across prime-target pairs, which should be reflected in the size of the priming effect (e.g., cat should prime dog more than animal does). However, it is only insightful to predict item-level priming effects if they can be measured reliably. Thus, in the present study we examined the split-half and test-retest reliabilities of item-level priming effects under conditions that should discourage the use of strategies. The resulting priming effects proved extremely unreliable, and reanalyses of three published priming datasets revealed similar cases of low reliability. These results imply that previous attempts to predict semantic priming were unlikely to be successful. However, one study with an unusually large sample size yielded more favorable reliability estimates, suggesting that big data, in terms of items and participants, should be the future for semantic priming research.

  5. Goniometric reliability in a clinical setting. Shoulder measurements.

    PubMed

    Riddle, D L; Rothstein, J M; Lamb, R L

    1987-05-01

    The purpose of this study was to examine the intratester and intertester reliabilities for clinical goniometric measurements of shoulder passive range of motion (PROM) using two different sizes of universal goniometers. Patients were measured without controlling therapist goniometric placement technique or patient position during measurements. Repeated PROM measurements of shoulder flexion, extension, abduction, shoulder horizontal abduction, horizontal adduction, lateral (external) rotation, and medial (internal) rotation were taken of two groups of 50 subjects each. The intratester intraclass correlation coefficients (ICCs) for all motions ranged from .87 to .99. The ICCs for the intertester reliability of PROM measurements of horizontal abduction, horizontal adduction, extension, and medial rotation ranged from .26 to .55. The intertester ICCs for PROM measurements of flexion, abduction, and lateral rotation ranged from .84 to .90. Goniometric PROM measurements for the shoulder appear to be highly reliable when taken by the same physical therapist, regardless of the size of the goniometer used. The degree of intertester reliability for these measurements appears to be range-of-motion specific.

  6. Management Education for Small and Medium-Sized Enterprises in the European Communities.

    ERIC Educational Resources Information Center

    Holzer, Rainer

    This report summarizes the activities of various bodies providing training impetus for small and medium-sized enterprises (SMEs) in Europe on the three levels of (1) basic management education for potential small and medium-sized business owners and/or managers; (2) programs for small firm start-ups; and (3) activities to improve the management of…

  7. 13 CFR 107.700 - Compliance with size standards in part 121 of this chapter as a condition of Assistance.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... Assistance SMALL BUSINESS ADMINISTRATION SMALL BUSINESS INVESTMENT COMPANIES Financing of Small Businesses by Licensees Determining the Eligibility of A Small Business for Sbic Financing § 107.700 Compliance with size... 13 Business Credit and Assistance 1 2010-01-01 2010-01-01 false Compliance with size standards in...

  8. Body mass estimates of hominin fossils and the evolution of human body size.

    PubMed

    Grabowski, Mark; Hatala, Kevin G; Jungers, William L; Richmond, Brian G

    2015-08-01

    Body size directly influences an animal's place in the natural world, including its energy requirements, home range size, relative brain size, locomotion, diet, life history, and behavior. Thus, an understanding of the biology of extinct organisms, including species in our own lineage, requires accurate estimates of body size. Since the last major review of hominin body size based on postcranial morphology over 20 years ago, new fossils have been discovered, species attributions have been clarified, and methods improved. Here, we present the most comprehensive and thoroughly vetted set of individual fossil hominin body mass predictions to date, and estimation equations based on a large (n = 220) sample of modern humans of known body masses. We also present species averages based exclusively on fossils with reliable taxonomic attributions, estimates of species averages by sex, and a metric for levels of sexual dimorphism. Finally, we identify individual traits that appear to be the most reliable for mass estimation for each fossil species, for use when only one measurement is available for a fossil. Our results show that many early hominins were generally smaller-bodied than previously thought, an outcome likely due to larger estimates in previous studies resulting from the use of large-bodied modern human reference samples. Current evidence indicates that modern human-like large size first appeared by at least 3-3.5 Ma in some Australopithecus afarensis individuals. Our results challenge an evolutionary model arguing that body size increased from Australopithecus to early Homo. Instead, we show that there is no reliable evidence that the body size of non-erectus early Homo differed from that of australopiths, and confirm that Homo erectus evolved larger average body size than earlier hominins. Copyright © 2015 Elsevier Ltd. All rights reserved.

  9. Particle size analysis of amalgam powder and handpiece generated specimens.

    PubMed

    Drummond, J L; Hathorn, R M; Cailas, M D; Karuhn, R

    2001-07-01

    The increasing interest in the elimination of amalgam particles from the dental waste (DW) stream, requires efficient devices to remove these particles. The major objective of this project was to perform a comparative evaluation of five basic methods of particle size analysis in terms of the instrument's ability to quantify the size distribution of the various components within the DW stream. The analytical techniques chosen were image analysis via scanning electron microscopy, standard wire mesh sieves, X-ray sedigraphy, laser diffraction, and electrozone analysis. The DW particle stream components were represented by amalgam powders and handpiece/diamond bur generated specimens of enamel; dentin, whole tooth, and condensed amalgam. Each analytical method quantified the examined DW particle stream components. However, X-ray sedigraphy, electrozone, and laser diffraction particle analyses provided similar results for determining particle distributions of DW samples. These three methods were able to more clearly quantify the properties of the examined powder and condensed amalgam samples. Furthermore, these methods indicated that a significant fraction of the DW stream contains particles less than 20 microm. The findings of this study indicated that the electrozone method is likely to be the most effective technique for quantifying the particle size distribution in the DW particle stream. This method required a relative small volume of sample, was not affected by density, shape factors or optical properties, and measured a sufficient number of particles to provide a reliable representation of the particle size distribution curve.

  10. Estimation of the genome sizes of the chigger mites Leptotrombidium pallidum and Leptotrombidium scutellare based on quantitative PCR and k-mer analysis

    PubMed Central

    2014-01-01

    Background Leptotrombidium pallidum and Leptotrombidium scutellare are the major vector mites for Orientia tsutsugamushi, the causative agent of scrub typhus. Before these organisms can be subjected to whole-genome sequencing, it is necessary to estimate their genome sizes to obtain basic information for establishing the strategies that should be used for genome sequencing and assembly. Method The genome sizes of L. pallidum and L. scutellare were estimated by a method based on quantitative real-time PCR. In addition, a k-mer analysis of the whole-genome sequences obtained through Illumina sequencing was conducted to verify the mutual compatibility and reliability of the results. Results The genome sizes estimated using qPCR were 191 ± 7 Mb for L. pallidum and 262 ± 13 Mb for L. scutellare. The k-mer analysis-based genome lengths were estimated to be 175 Mb for L. pallidum and 286 Mb for L. scutellare. The estimates from these two independent methods were mutually complementary and within a similar range to those of other Acariform mites. Conclusions The estimation method based on qPCR appears to be a useful alternative when the standard methods, such as flow cytometry, are impractical. The relatively small estimated genome sizes should facilitate whole-genome analysis, which could contribute to our understanding of Arachnida genome evolution and provide key information for scrub typhus prevention and mite vector competence. PMID:24947244

  11. The Scaling of Performance and Losses in Miniature Internal Combustion Engines

    DTIC Science & Technology

    2010-01-01

    reliable measurements of engine performance and losses in these small engines. Methodologies are also developed for measuring volumetric, heat transfer...making reliable measurements of engine performance and losses in these small engines. Methodologies are also developed for measuring volumetric, heat ...the most important challenge as it accounts for 60-70% of total energy losses. Combustion losses are followed in order of importance by heat transfer

  12. FY12 End of Year Report for NEPP DDR2 Reliability

    NASA Technical Reports Server (NTRS)

    Guertin, Steven M.

    2013-01-01

    This document reports the status of the NASA Electronic Parts and Packaging (NEPP) Double Data Rate 2 (DDR2) Reliability effort for FY2012. The task expanded the focus of evaluating reliability effects targeted for device examination. FY11 work highlighted the need to test many more parts and to examine more operating conditions, in order to provide useful recommendations for NASA users of these devices. This year's efforts focused on development of test capabilities, particularly focusing on those that can be used to determine overall lot quality and identify outlier devices, and test methods that can be employed on components for flight use. Flight acceptance of components potentially includes considerable time for up-screening (though this time may not currently be used for much reliability testing). Manufacturers are much more knowledgeable about the relevant reliability mechanisms for each of their devices. We are not in a position to know what the appropriate reliability tests are for any given device, so although reliability testing could be focused for a given device, we are forced to perform a large campaign of reliability tests to identify devices with degraded reliability. With the available up-screening time for NASA parts, it is possible to run many device performance studies. This includes verification of basic datasheet characteristics. Furthermore, it is possible to perform significant pattern sensitivity studies. By doing these studies we can establish higher reliability of flight components. In order to develop these approaches, it is necessary to develop test capability that can identify reliability outliers. To do this we must test many devices to ensure outliers are in the sample, and we must develop characterization capability to measure many different parameters. For FY12 we increased capability for reliability characterization and sample size. We increased sample size this year by moving from loose devices to dual inline memory modules (DIMMs) with an approximate reduction of 20 to 50 times in terms of per device under test (DUT) cost. By increasing sample size we have improved our ability to characterize devices that may be considered reliability outliers. This report provides an update on the effort to improve DDR2 testing capability. Although focused on DDR2, the methods being used can be extended to DDR and DDR3 with relative ease.

  13. Using meta-analysis to inform the design of subsequent studies of diagnostic test accuracy.

    PubMed

    Hinchliffe, Sally R; Crowther, Michael J; Phillips, Robert S; Sutton, Alex J

    2013-06-01

    An individual diagnostic accuracy study rarely provides enough information to make conclusive recommendations about the accuracy of a diagnostic test; particularly when the study is small. Meta-analysis methods provide a way of combining information from multiple studies, reducing uncertainty in the result and hopefully providing substantial evidence to underpin reliable clinical decision-making. Very few investigators consider any sample size calculations when designing a new diagnostic accuracy study. However, it is important to consider the number of subjects in a new study in order to achieve a precise measure of accuracy. Sutton et al. have suggested previously that when designing a new therapeutic trial, it could be more beneficial to consider the power of the updated meta-analysis including the new trial rather than of the new trial itself. The methodology involves simulating new studies for a range of sample sizes and estimating the power of the updated meta-analysis with each new study added. Plotting the power values against the range of sample sizes allows the clinician to make an informed decision about the sample size of a new trial. This paper extends this approach from the trial setting and applies it to diagnostic accuracy studies. Several meta-analytic models are considered including bivariate random effects meta-analysis that models the correlation between sensitivity and specificity. Copyright © 2012 John Wiley & Sons, Ltd. Copyright © 2012 John Wiley & Sons, Ltd.

  14. Comparison of size modulation and conventional standard automated perimetry with the 24-2 test protocol in glaucoma patients

    NASA Astrophysics Data System (ADS)

    Hirasawa, Kazunori; Shoji, Nobuyuki; Kasahara, Masayuki; Matsumura, Kazuhiro; Shimizu, Kimiya

    2016-05-01

    This prospective randomized study compared test results of size modulation standard automated perimetry (SM-SAP) performed with the Octopus 600 and conventional SAP (C-SAP) performed with the Humphrey Field Analyzer (HFA) in glaucoma patients. Eighty-eight eyes of 88 glaucoma patients underwent SM-SAP and C-SAP tests with the Octopus 600 24-2 Dynamic and HFA 24-2 SITA-Standard, respectively. Fovea threshold, mean defect, and square loss variance of SM-SAP were significantly correlated with the corresponding C-SAP indices (P < 0.001). The false-positive rate was slightly lower, and false-negative rate slightly higher, with SM-SAP than C-SAP (P = 0.002). Point-wise threshold values obtained with SM-SAP were moderately to strongly correlated with those obtained with C-SAP (P < 0.001). The correlation coefficients of the central zone were significantly lower than those of the middle to peripheral zone (P = 0.031). The size and depth of the visual field (VF) defect were smaller (P = 0.039) and greater (P = 0.043), respectively, on SM-SAP than on C-SAP. Although small differences were observed in VF sensitivity in the central zone, the defect size and depth and the reliability indices between SM-SAP and C-SAP, global indices of the two testing modalities were well correlated.

  15. Does fluctuating asymmetry of antlers in white-tailed deer (Odocoileus virginianus) follow patterns predicted for sexually selected traits?

    USGS Publications Warehouse

    Ditchkoff, S.S.; Lochmiller, R.L.; Masters, R.E.; Starry, W.R.; Leslie, David M.

    2001-01-01

    Secondary sexual characters have been hypothesized to signal male quality and should demonstrate a negative relationship between the size of the trait and degree of fluctuating asymmetry because they are costly to produce. We collected morphometric and antler data from 439 white-tailed deer (Odocoileus virginianus) in Oklahoma, USA, in order to determine whether measures of antler asymmetry follow the patterns predicted for sexually selected characters. Relative fluctuating asymmetry was negatively related to antler size for all deer and within age groups up to five and a half years of age. We did not detect an association between asymmetry and antler size among deer that were six and a half years or older. When categorizing deer by antler size, we found that deer with small antlers (???33rd percentile) had greater levels of relative asymmetry than deer with large antlers (???67th percentile). The relative asymmetry of antlers was negatively related to age and was greatest in deer that were one and a half years old. Relative asymmetry was also negatively related to carcass mass, inside spread, skull length and body length. These data suggest that asymmetry in the antlers of white-tailed deer may be a reliable signal of quality and, as such, may be important in maintaining honesty in intrasexual advertisements during the breeding season.

  16. Plant-mediated effects on extracellular enzyme activities in distinct soil aggregate size classes in field

    NASA Astrophysics Data System (ADS)

    Kumar, Amit; Dorodnikov, Maxim; Splettstößer, Thomas; Kuzyakov, Yakov; Pausch, Johanna

    2017-04-01

    Soil aggregation and microbial activities within the aggregates are important factors regulating soil carbon (C) turnover. A reliable and sensitive proxy for microbial activity is activity of extracellular enzymes (EEA). In the present study, effects of soil aggregates on EEA were investigated under three maize plant densities (Low, Normal, and High). Bulk soil was fractionated into three aggregate size classes (>2000 µm large macroaggregates; 2000-250 µm small macroaggregates; <250 µm microaggregates) by optimal-moisture sieving. Microbial biomass and EEA (β-1,4-glucosidase (BG), β-1,4-N-acetylglucosaminidase (NAG), L-leucine aminopeptidase (LAP) and acid phosphatase (acP)) catalyzing soil organic matter (SOM) decomposition were measured in rooted soil of maize and soil from bare fallow. Microbial biomass C (Cmic) decreased with decreasing aggregate size classes. Potential and specific EEA (per unit of Cmic) increased from macro- to microaggregates. In comparison with bare fallow soil, specific EEA of microaggregates in rooted soil was higher by up to 73%, 31%, 26%, and 92% for BG, NAG, acP and LAP, respectively. Moreover, high plant density decreased macroaggregates by 9% compared to bare fallow. Enhanced EEA in three aggregate size classes demonstrated activation of microorganisms by roots. Strong EEA in microaggregates can be explained by microaggregates' localization within the soil. Originally adhering to surfaces of macroaggregates, microaggregates were preferentially exposed to C substrates and nutrients, thereby promoting microbial activity.

  17. Phased array inspection of large size forged steel parts

    NASA Astrophysics Data System (ADS)

    Dupont-Marillia, Frederic; Jahazi, Mohammad; Belanger, Pierre

    2018-04-01

    High strength forged steel requires uncompromising quality to warrant advance performance for numerous critical applications. Ultrasonic inspection is commonly used in nondestructive testing to detect cracks and other defects. In steel blocks of relatively small dimensions (at least two directions not exceeding a few centimetres), phased array inspection is a trusted method to generate images of the inside of the blocks and therefore identify and size defects. However, casting of large size forged ingots introduces changes of mechanical parameters such as grain size, the Young's modulus, the Poisson's ratio, and the chemical composition. These heterogeneities affect the wave propagation, and consequently, the reliability of ultrasonic inspection and the imaging capabilities for these blocks. In this context, a custom phased array transducer designed for a 40-ton bainitic forged ingot was investigated. Following a previous study that provided local mechanical parameters for a similar block, two-dimensional simulations were made to compute the optimal transducer parameters including the pitch, width and number of elements. It appeared that depending on the number of elements, backwall reconstruction can generate high amplitude artefacts. Indeed, the large dimensions of the simulated block introduce numerous constructive interferences from backwall reflections which may lead to important artefacts. To increase image quality, the reconstruction algorithm was adapted and promising results were observed and compared with the scattering cone filter method available in the CIVA software.

  18. New International Program to Asses the Reliability of Emerging Nondestructive Techniques (PARENT)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Prokofiev, Iouri; Cumblidge, Stephen E.; Csontos, Aladar A.

    2013-01-25

    The Nuclear Regulatory Commission (NRC) established the Program to Assess the Reliability of Emerging Nondestructive Techniques (PARENT) to follow on from the successful Program for the Inspection of Nickel alloy Components (PINC). The goal of the PARENT is to conduct a confirmatory assessment of the reliability of nondestructive evaluation (NDE) techniques for detecting and sizing primary water stress corrosion cracks (PWSCC) and applying the lessons learned from PINC to a series of round-robin tests. These open and blind round-robin tests will comprise a new set of typical pressure boundary components including dissimilar metal welds (DMWs) and bottom-mounted instrumentation penetrations. Openmore » round-robin tests will engage research and industry teams worldwide to investigate and demonstrate the reliability of emerging NDE techniques to detect and size flaws with a wide range of lengths, depths, orientations, and locations. Blind round-robin tests will utilize various testing organizations, whose inspectors and procedures are certified by the standards for the nuclear industry in their respective countries, to investigate the ability of established NDE techniques to detect and size flaws whose characteristics range from relatively easy to very difficult for detection and sizing. Blind and open round-robin testing started in late 2011 and early 2012, respectively. This paper will present the work scope with reports on progress, NDE methods evaluated, and project timeline for PARENT.« less

  19. The Children's Body Image Scale: reliability and use with international standards for body mass index.

    PubMed

    Truby, Helen; Paxton, Susan J

    2008-03-01

    To test the reliability of the Children's Body Image Scale (CBIS) and assess its usefulness in the context of new body size charts for children. Participants were 281 primary schoolchildren with 50% being retested after 3 weeks. The CBIS figure scale was compared with a range of international body mass index (BMI) reference standards. Children had a high degree of body image dissatisfaction. The test-retest reliability of the CBIS was supported. The CBIS is a useful tool for assessing body image in children with sound scale properties. It can also be used to identify the body size of children, which lies outside the healthy weight range of BMI.

  20. The endothelial sample size analysis in corneal specular microscopy clinical examinations.

    PubMed

    Abib, Fernando C; Holzchuh, Ricardo; Schaefer, Artur; Schaefer, Tania; Godois, Ronialci

    2012-05-01

    To evaluate endothelial cell sample size and statistical error in corneal specular microscopy (CSM) examinations. One hundred twenty examinations were conducted with 4 types of corneal specular microscopes: 30 with each BioOptics, CSO, Konan, and Topcon corneal specular microscopes. All endothelial image data were analyzed by respective instrument software and also by the Cells Analyzer software with a method developed in our lab. A reliability degree (RD) of 95% and a relative error (RE) of 0.05 were used as cut-off values to analyze images of the counted endothelial cells called samples. The sample size mean was the number of cells evaluated on the images obtained with each device. Only examinations with RE < 0.05 were considered statistically correct and suitable for comparisons with future examinations. The Cells Analyzer software was used to calculate the RE and customized sample size for all examinations. Bio-Optics: sample size, 97 ± 22 cells; RE, 6.52 ± 0.86; only 10% of the examinations had sufficient endothelial cell quantity (RE < 0.05); customized sample size, 162 ± 34 cells. CSO: sample size, 110 ± 20 cells; RE, 5.98 ± 0.98; only 16.6% of the examinations had sufficient endothelial cell quantity (RE < 0.05); customized sample size, 157 ± 45 cells. Konan: sample size, 80 ± 27 cells; RE, 10.6 ± 3.67; none of the examinations had sufficient endothelial cell quantity (RE > 0.05); customized sample size, 336 ± 131 cells. Topcon: sample size, 87 ± 17 cells; RE, 10.1 ± 2.52; none of the examinations had sufficient endothelial cell quantity (RE > 0.05); customized sample size, 382 ± 159 cells. A very high number of CSM examinations had sample errors based on Cells Analyzer software. The endothelial sample size (examinations) needs to include more cells to be reliable and reproducible. The Cells Analyzer tutorial routine will be useful for CSM examination reliability and reproducibility.

  1. Reliability generalization study of the Yale-Brown Obsessive-Compulsive Scale for children and adolescents.

    PubMed

    López-Pina, José Antonio; Sánchez-Meca, Julio; López-López, José Antonio; Marín-Martínez, Fulgencio; Núñez-Núñez, Rosa Ma; Rosa-Alcázar, Ana I; Gómez-Conesa, Antonia; Ferrer-Requena, Josefa

    2015-01-01

    The Yale-Brown Obsessive-Compulsive Scale for children and adolescents (CY-BOCS) is a frequently applied test to assess obsessive-compulsive symptoms. We conducted a reliability generalization meta-analysis on the CY-BOCS to estimate the average reliability, search for reliability moderators, and propose a predictive model that researchers and clinicians can use to estimate the expected reliability of the CY-BOCS scores. A total of 47 studies reporting a reliability coefficient with the data at hand were included in the meta-analysis. The results showed good reliability and a large variability associated to the standard deviation of total scores and sample size.

  2. Reliability and cost evaluation of small isolated power systems containing photovoltaic and wind energy

    NASA Astrophysics Data System (ADS)

    Karki, Rajesh

    Renewable energy application in electric power systems is growing rapidly worldwide due to enhanced public concerns for adverse environmental impacts and escalation in energy costs associated with the use of conventional energy sources. Photovoltaics and wind energy sources are being increasingly recognized as cost effective generation sources. A comprehensive evaluation of reliability and cost is required to analyze the actual benefits of utilizing these energy sources. The reliability aspects of utilizing renewable energy sources have largely been ignored in the past due the relatively insignificant contribution of these sources in major power systems, and consequently due to the lack of appropriate techniques. Renewable energy sources have the potential to play a significant role in the electrical energy requirements of small isolated power systems which are primarily supplied by costly diesel fuel. A relatively high renewable energy penetration can significantly reduce the system fuel costs but can also have considerable impact on the system reliability. Small isolated systems routinely plan their generating facilities using deterministic adequacy methods that cannot incorporate the highly erratic behavior of renewable energy sources. The utilization of a single probabilistic risk index has not been generally accepted in small isolated system evaluation despite its utilization in most large power utilities. Deterministic and probabilistic techniques are combined in this thesis using a system well-being approach to provide useful adequacy indices for small isolated systems that include renewable energy. This thesis presents an evaluation model for small isolated systems containing renewable energy sources by integrating simulation models that generate appropriate atmospheric data, evaluate chronological renewable power outputs and combine total available energy and load to provide useful system indices. A software tool SIPSREL+ has been developed which generates risk, well-being and energy based indices to provide realistic cost/reliability measures of utilizing renewable energy. The concepts presented and the examples illustrated in this thesis will help system planners to decide on appropriate installation sites, the types and mix of different energy generating sources, the optimum operating policies, and the optimum generation expansion plans required to meet increasing load demands in small isolated power systems containing photovoltaic and wind energy sources.

  3. Reliability of Different Mark-Recapture Methods for Population Size Estimation Tested against Reference Population Sizes Constructed from Field Data

    PubMed Central

    Grimm, Annegret; Gruber, Bernd; Henle, Klaus

    2014-01-01

    Reliable estimates of population size are fundamental in many ecological studies and biodiversity conservation. Selecting appropriate methods to estimate abundance is often very difficult, especially if data are scarce. Most studies concerning the reliability of different estimators used simulation data based on assumptions about capture variability that do not necessarily reflect conditions in natural populations. Here, we used data from an intensively studied closed population of the arboreal gecko Gehyra variegata to construct reference population sizes for assessing twelve different population size estimators in terms of bias, precision, accuracy, and their 95%-confidence intervals. Two of the reference populations reflect natural biological entities, whereas the other reference populations reflect artificial subsets of the population. Since individual heterogeneity was assumed, we tested modifications of the Lincoln-Petersen estimator, a set of models in programs MARK and CARE-2, and a truncated geometric distribution. Ranking of methods was similar across criteria. Models accounting for individual heterogeneity performed best in all assessment criteria. For populations from heterogeneous habitats without obvious covariates explaining individual heterogeneity, we recommend using the moment estimator or the interpolated jackknife estimator (both implemented in CAPTURE/MARK). If data for capture frequencies are substantial, we recommend the sample coverage or the estimating equation (both models implemented in CARE-2). Depending on the distribution of catchabilities, our proposed multiple Lincoln-Petersen and a truncated geometric distribution obtained comparably good results. The former usually resulted in a minimum population size and the latter can be recommended when there is a long tail of low capture probabilities. Models with covariates and mixture models performed poorly. Our approach identified suitable methods and extended options to evaluate the performance of mark-recapture population size estimators under field conditions, which is essential for selecting an appropriate method and obtaining reliable results in ecology and conservation biology, and thus for sound management. PMID:24896260

  4. Intraspecific variation in body size does not alter the effects of mesopredators on prey.

    PubMed

    Gallagher, Austin J; Brandl, Simon J; Stier, Adrian C

    2016-12-01

    As humans continue to alter the species composition and size structure of marine food webs, it is critical to understand size-dependent effects of predators on prey. Yet, how shifts in predator body size mediate the effect of predators is understudied in tropical marine ecosystems, where anthropogenic harvest has indirectly increased the density and size of small-bodied predators. Here, we combine field surveys and a laboratory feeding experiment in coral reef fish communities to show that small and large predators of the same species can have similar effects. Specifically, surveys show that the presence of a small predator ( Paracirrhites arcatus ) was correlated with lower chances of prey fish presence, but these correlations were independent of predator size. Experimental trials corroborated the size-independent effect of the predator; attack rates were indistinguishable between small and large predators, suggesting relatively even effects of hawkfish in various size classes on the same type of prey. Our results indicate that the effects of small predators on coral reefs can be size-independent, suggesting that variation in predator size-structure alone may not always affect the functional role of these predators.

  5. A global/local affinity graph for image segmentation.

    PubMed

    Xiaofang Wang; Yuxing Tang; Masnou, Simon; Liming Chen

    2015-04-01

    Construction of a reliable graph capturing perceptual grouping cues of an image is fundamental for graph-cut based image segmentation methods. In this paper, we propose a novel sparse global/local affinity graph over superpixels of an input image to capture both short- and long-range grouping cues, and thereby enabling perceptual grouping laws, including proximity, similarity, continuity, and to enter in action through a suitable graph-cut algorithm. Moreover, we also evaluate three major visual features, namely, color, texture, and shape, for their effectiveness in perceptual segmentation and propose a simple graph fusion scheme to implement some recent findings from psychophysics, which suggest combining these visual features with different emphases for perceptual grouping. In particular, an input image is first oversegmented into superpixels at different scales. We postulate a gravitation law based on empirical observations and divide superpixels adaptively into small-, medium-, and large-sized sets. Global grouping is achieved using medium-sized superpixels through a sparse representation of superpixels' features by solving a ℓ0-minimization problem, and thereby enabling continuity or propagation of local smoothness over long-range connections. Small- and large-sized superpixels are then used to achieve local smoothness through an adjacent graph in a given feature space, and thus implementing perceptual laws, for example, similarity and proximity. Finally, a bipartite graph is also introduced to enable propagation of grouping cues between superpixels of different scales. Extensive experiments are carried out on the Berkeley segmentation database in comparison with several state-of-the-art graph constructions. The results show the effectiveness of the proposed approach, which outperforms state-of-the-art graphs using four different objective criteria, namely, the probabilistic rand index, the variation of information, the global consistency error, and the boundary displacement error.

  6. Prognostic value of tumor size in gastric cancer: an analysis of 2,379 patients.

    PubMed

    Guo, Pengtao; Li, Yangming; Zhu, Zhi; Sun, Zhe; Lu, Chong; Wang, Zhenning; Xu, Huimian

    2013-04-01

    Tumor size has been included into the staging systems of many solid tumors, such as lung and breast. However, tumor size is not integrated in the staging of gastric cancer, and its prognostic value for gastric cancer needs to be reappraised. A total of 2,379 patients who received radical resection for histopathologically confirmed gastric adenocarcinoma were enrolled in the present study. Tumor size, originally presented as continuous variable, was categorized into small gastric cancer (SGC) group and large gastric cancer (LGC) group using an optimal cutoff point determined by Cox proportional hazards model. The associations between tumor size and other clinicopathological factors were checked using Chi-square test. Survival of gastric cancer patients was estimated by using univariate Kaplan-Meier method, and the survival difference was checked by using the log-rank test. The significant clinicopathological factors were included into the Cox proportional hazards model to determine the independent prognostic factors, and their hazard ratios were calculated. With the optimal cutoff point of 4 cm, tumor size was categorized into SGC group (≤ 4 cm) and LGC group (>4 cm). Tumor size closely correlated with age, tumor location, macroscopic type, Lauren classification, and lymphatic vessel invasion. Moreover, tumor size was also significantly associated with depth of tumor invasion and status of regional lymph nodes. The 5-year survival rate was 68.7 % for SGC group which was much higher than 40.2 % for LGC group. Univariate analysis showed that SGC had a better survival than LGC, mainly for patients with IIA, IIB, and IIIA stage. Multivariate analysis revealed that tumor size as well as age, tumor location, macroscopic type, Lauren classification, lymphatic vessel invasion, depth of tumor invasion, and status of regional lymph nodes were independent prognostic factors for gastric cancer. Tumor size is a reliable prognostic factor for patients with gastric cancer, and the measurement of tumor size would be helpful to the staging and management of gastric cancer.

  7. Reliability and precision of pellet-group counts for estimating landscape-level deer density

    Treesearch

    David S. deCalesta

    2013-01-01

    This study provides hitherto unavailable methodology for reliably and precisely estimating deer density within forested landscapes, enabling quantitative rather than qualitative deer management. Reliability and precision of the deer pellet-group technique were evaluated in 1 small and 2 large forested landscapes. Density estimates, adjusted to reflect deer harvest and...

  8. A Simple and Reliable Method of Design for Standalone Photovoltaic Systems

    NASA Astrophysics Data System (ADS)

    Srinivasarao, Mantri; Sudha, K. Rama; Bhanu, C. V. K.

    2017-06-01

    Standalone photovoltaic (SAPV) systems are seen as a promoting method of electrifying areas of developing world that lack power grid infrastructure. Proliferations of these systems require a design procedure that is simple, reliable and exhibit good performance over its life time. The proposed methodology uses simple empirical formulae and easily available parameters to design SAPV systems, that is, array size with energy storage. After arriving at the different array size (area), performance curves are obtained for optimal design of SAPV system with high amount of reliability in terms of autonomy at a specified value of loss of load probability (LOLP). Based on the array to load ratio (ALR) and levelized energy cost (LEC) through life cycle cost (LCC) analysis, it is shown that the proposed methodology gives better performance, requires simple data and is more reliable when compared with conventional design using monthly average daily load and insolation.

  9. Identifying key demographic parameters of a small island-associated population of Indo-Pacific bottlenose dolphins (Reunion, Indian Ocean).

    PubMed

    Dulau, Violaine; Estrade, Vanessa; Fayan, Jacques

    2017-01-01

    Photo-identification surveys of Indo-Pacific bottlenose dolphins were conducted from 2009 to 2014 off Reunion Island (55°E33'/21°S07'), in the Indian Ocean. Robust Design models were applied to produce the most reliable estimate of population abundance and survival rate, while accounting for temporary emigration from the survey area (west coast). The sampling scheme consisted of a five-month (June-October) sampling period in each year of the study. The overall population size at Reunion was estimated to be 72 individuals (SE = 6.17, 95%CI = 61-85), based on a random temporary emigration (γ") of 0.096 and a proportion of 0.70 (SE = 0.03) distinct individuals. The annual survival rate was 0.93 (±0.018 SE, 95%CI = 0.886-0.958) and was constant over time and between sexes. Models considering gender groups indicated different movement patterns between males and females. Males showed null or quasi-null temporary emigration (γ" = γ' < 0.01), while females showed a random temporary emigration (γ") of 0.10, suggesting that a small proportion of females was outside the survey area during each primary sampling period. Sex-specific temporary migration patterns were consistent with movement and residency patterns observed in other areas. The Robust Design approach provided an appropriate sampling scheme for deriving island-associated population parameters, while allowing to restrict survey effort both spatially (i.e. west coast only) and temporally (five months per year). Although abundance and survival were stable over the six years, the small population size of fewer than 100 individuals suggested that this population is highly vulnerable. Priority should be given to reducing any potential impact of human activity on the population and its habitat.

  10. CoLIde: a bioinformatics tool for CO-expression-based small RNA Loci Identification using high-throughput sequencing data.

    PubMed

    Mohorianu, Irina; Stocks, Matthew Benedict; Wood, John; Dalmay, Tamas; Moulton, Vincent

    2013-07-01

    Small RNAs (sRNAs) are 20-25 nt non-coding RNAs that act as guides for the highly sequence-specific regulatory mechanism known as RNA silencing. Due to the recent increase in sequencing depth, a highly complex and diverse population of sRNAs in both plants and animals has been revealed. However, the exponential increase in sequencing data has also made the identification of individual sRNA transcripts corresponding to biological units (sRNA loci) more challenging when based exclusively on the genomic location of the constituent sRNAs, hindering existing approaches to identify sRNA loci. To infer the location of significant biological units, we propose an approach for sRNA loci detection called CoLIde (Co-expression based sRNA Loci Identification) that combines genomic location with the analysis of other information such as variation in expression levels (expression pattern) and size class distribution. For CoLIde, we define a locus as a union of regions sharing the same pattern and located in close proximity on the genome. Biological relevance, detected through the analysis of size class distribution, is also calculated for each locus. CoLIde can be applied on ordered (e.g., time-dependent) or un-ordered (e.g., organ, mutant) series of samples both with or without biological/technical replicates. The method reliably identifies known types of loci and shows improved performance on sequencing data from both plants (e.g., A. thaliana, S. lycopersicum) and animals (e.g., D. melanogaster) when compared with existing locus detection techniques. CoLIde is available for use within the UEA Small RNA Workbench which can be downloaded from: http://srna-workbench.cmp.uea.ac.uk.

  11. Improving image quality in laboratory x-ray phase-contrast imaging

    NASA Astrophysics Data System (ADS)

    De Marco, F.; Marschner, M.; Birnbacher, L.; Viermetz, M.; Noël, P.; Herzen, J.; Pfeiffer, F.

    2017-03-01

    Grating-based X-ray phase-contrast (gbPC) is known to provide significant benefits for biomedical imaging. To investigate these benefits, a high-sensitivity gbPC micro-CT setup for small (≍ 5 cm) biological samples has been constructed. Unfortunately, high differential-phase sensitivity leads to an increased magnitude of data processing artifacts, limiting the quality of tomographic reconstructions. Most importantly, processing of phase-stepping data with incorrect stepping positions can introduce artifacts resembling Moiré fringes to the projections. Additionally, the focal spot size of the X-ray source limits resolution of tomograms. Here we present a set of algorithms to minimize artifacts, increase resolution and improve visual impression of projections and tomograms from the examined setup. We assessed two algorithms for artifact reduction: Firstly, a correction algorithm exploiting correlations of the artifacts and differential-phase data was developed and tested. Artifacts were reliably removed without compromising image data. Secondly, we implemented a new algorithm for flatfield selection, which was shown to exclude flat-fields with strong artifacts. Both procedures successfully improved image quality of projections and tomograms. Deconvolution of all projections of a CT scan can minimize blurring introduced by the finite size of the X-ray source focal spot. Application of the Richardson-Lucy deconvolution algorithm to gbPC-CT projections resulted in an improved resolution of phase-contrast tomograms. Additionally, we found that nearest-neighbor interpolation of projections can improve the visual impression of very small features in phase-contrast tomograms. In conclusion, we achieved an increase in image resolution and quality for the investigated setup, which may lead to an improved detection of very small sample features, thereby maximizing the setup's utility.

  12. Estimating the Population Size of Female Sex Worker Population in Tehran, Iran: Application of Direct Capture-Recapture Method.

    PubMed

    Karami, Manoochehr; Khazaei, Salman; Poorolajal, Jalal; Soltanian, Alireza; Sajadipoor, Mansour

    2017-08-01

    There is no reliable estimate of the size of female sex workers (FSWs). This study aimed to estimate the size of FSWs in south of Tehran, Iran in 2016 using direct capture-recapture method. In the capture phase, the hangouts of FSWs were mapped as their meeting places. FSWs who agreed to participate in the study tagged with a T-shirt. The recapture phase was implemented at the same places tagging FSWs with a blue bracelet. The total estimated size of FSWs was 690 (95% CI 633, 747). About 89.43% of FSWs experienced sexual intercourse prior to age 20. The prevalence of human immunodeficiency virus infection among FSWs was 4.60%. The estimated population size of FSWs was much more than our expectation. This issue must be the focus of special attention for planning prevention strategies. However, alternative estimates require to estimating the number FSWs, reliably.

  13. Vision technology/algorithms for space robotics applications

    NASA Technical Reports Server (NTRS)

    Krishen, Kumar; Defigueiredo, Rui J. P.

    1987-01-01

    The thrust of automation and robotics for space applications has been proposed for increased productivity, improved reliability, increased flexibility, higher safety, and for the performance of automating time-consuming tasks, increasing productivity/performance of crew-accomplished tasks, and performing tasks beyond the capability of the crew. This paper provides a review of efforts currently in progress in the area of robotic vision. Both systems and algorithms are discussed. The evolution of future vision/sensing is projected to include the fusion of multisensors ranging from microwave to optical with multimode capability to include position, attitude, recognition, and motion parameters. The key feature of the overall system design will be small size and weight, fast signal processing, robust algorithms, and accurate parameter determination. These aspects of vision/sensing are also discussed.

  14. Compact Feed Circuit with Quarter Wavelength Transmission Line Matrix Controlling Beams in Three Directions Including Boresight

    NASA Astrophysics Data System (ADS)

    Tsuji, Masatoshi

    A compact feed circuit with a λ/4 transmission line matrix circuit for use in array antennas to control beams in three directions, including boresight, is presented. The feed circuit antenna is composed of five switches and λ/4 transmission lines, and the feeding matrix circuit yields phase differences of ±90° and 0°. The feed circuit can obtain a reliable output signal, as there is only a small degree of deviation of output signal with variations in the line width. The feed circuit is simulated, fabricated, and evaluated for ISM band, and the measured characteristics agree well with the results of the simulation. The size of feed circuit is 45 (H) × 48 (W) × 3 (T) mm.

  15. Do Personality Problems Improve During Psychodynamic Supportive-Expressive Psychotherapy? Secondary Outcome Results From a Randomized Controlled Trial for Psychiatric Outpatients with Personality Disorders

    PubMed Central

    Vinnars, Bo; Thormählen, Barbro; Gallop, Robert; Norén, Kristina; Barber, Jacques P.

    2009-01-01

    Studies involving patients with personality disorders (PD) have not focused on improvement of core aspects of the PD. This paper examines changes in quality of object relations, interpersonal problems, psychological mindedness, and personality traits in a sample of 156 patients with DSM-IV PD diagnoses being randomized to either manualized or non manualized dynamic psychotherapy. Effect sizes adjusted for symptomatic change and reliable change indices were calculated. We found that both treatments were equally effective at reducing personality pathology. Only in neuroticism did the non manualized group do better during the follow-up period. The largest improvement was found in quality of object relations. For the remaining variables only small and clinically insignificant magnitudes of change were found. PMID:20161588

  16. Software Design Improvements. Part 1; Software Benefits and Limitations

    NASA Technical Reports Server (NTRS)

    Lalli, Vincent R.; Packard, Michael H.; Ziemianski, Tom

    1997-01-01

    Computer hardware and associated software have been used for many years to process accounting information, to analyze test data and to perform engineering analysis. Now computers and software also control everything from automobiles to washing machines and the number and type of applications are growing at an exponential rate. The size of individual program has shown similar growth. Furthermore, software and hardware are used to monitor and/or control potentially dangerous products and safety-critical systems. These uses include everything from airplanes and braking systems to medical devices and nuclear plants. The question is: how can this hardware and software be made more reliable? Also, how can software quality be improved? What methodology needs to be provided on large and small software products to improve the design and how can software be verified?

  17. High current plasma electron emitter

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fiksel, G.; Almagri, A.F.; Craig, D.

    1995-07-01

    A high current plasma electron emitter based on a miniature plasma source has been developed. The emitting plasma is created by a pulsed high current gas discharge. The electron emission current is 1 kA at 300 V at the pulse duration of 10 ms. The prototype injector described in this paper will be used for a 20 kA electrostatic current injection experiment in the Madison Symmetric Torus (MST) reversed-field pinch. The source will be replicated in order to attain this total current requirement. The source has a simple design and has proven very reliable in operation. A high emission current,more » small size (3.7 cm in diameter), and low impurity generation make the source suitable for a variety of fusion and technological applications.« less

  18. Simulation of Voltage SET Operation in Phase-Change Random Access Memories with Heater Addition and Ring-Type Contactor for Low-Power Consumption by Finite Element Modeling

    NASA Astrophysics Data System (ADS)

    Gong, Yue-Feng; Song, Zhi-Tang; Ling, Yun; Liu, Yan; Li, Yi-Jin

    2010-06-01

    A three-dimensional finite element model for phase change random access memory is established to simulate electric, thermal and phase state distribution during (SET) operation. The model is applied to simulate the SET behaviors of the heater addition structure (HS) and the ring-type contact in the bottom electrode (RIB) structure. The simulation results indicate that the small bottom electrode contactor (BEC) is beneficial for heat efficiency and reliability in the HS cell, and the bottom electrode contactor with size Fx = 80 nm is a good choice for the RIB cell. Also shown is that the appropriate SET pulse time is 100 ns for the low power consumption and fast operation.

  19. Validation of the Spanish SIRS with monolingual Hispanic outpatients.

    PubMed

    Correa, Amor A; Rogers, Richard; Hoersting, Raquel

    2010-09-01

    Psychologists are faced with formidable challenges in making their assessment methods relevant to growing numbers of Hispanic clients for whom English is not the primary or preferred language. Among other clinical issues, the determination of malingering has profound consequences for clients. In this investigation, we evaluated a Spanish translation of the Structured Interview of Reported Symptoms (SIRS; Rogers, Bagby, & Dickens, 1992) with 80 Spanish-speaking Hispanic American outpatients. Using a between-subjects simulation design, the Spanish SIRS was found to produce reliable results with small standard errors of measurement. Regarding validity, very large effect sizes (mean Cohen's d= 2.00) were observed between feigners and honest responders for the SIRS primary scales. We consider the potential role of the Spanish SIRS with reference to Spanish translations for other assessment instruments.

  20. Forensic analysis of dyed textile fibers.

    PubMed

    Goodpaster, John V; Liszewski, Elisa A

    2009-08-01

    Textile fibers are a key form of trace evidence, and the ability to reliably associate or discriminate them is crucial for forensic scientists worldwide. While microscopic and instrumental analysis can be used to determine the composition of the fiber itself, additional specificity is gained by examining fiber color. This is particularly important when the bulk composition of the fiber is relatively uninformative, as it is with cotton, wool, or other natural fibers. Such analyses pose several problems, including extremely small sample sizes, the desire for nondestructive techniques, and the vast complexity of modern dye compositions. This review will focus on more recent methods for comparing fiber color by using chromatography, spectroscopy, and mass spectrometry. The increasing use of multivariate statistics and other data analysis techniques for the differentiation of spectra from dyed fibers will also be discussed.

  1. Measurement of actinides and strontium-90 in high activity waste

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Maxwell, S.L. III; Nelson, M.R.

    1994-08-01

    The reliable measurement of trace radionuclides in high activity waste is important to support waste processing activities at SRS (F and H Area Waste Tanks, Extended Sludge Processing (ESP) and In-Tank precipitation (ITP) processing). Separation techniques are needed to remove high levels of gamma activity and alpha/beta interferences prior to analytical measurement. Using new extraction chromatographic resins from EiChrom Industries, Inc., the SRS Central Laboratory has developed new high speed separation methods that enable measurement of neptunium, thorium, uranium, plutonium, americium and strontium-90 in high activity waste solutions. Small particle size resin and applied vacuum are used to reduce analysismore » times and enhance column performance. Extraction chromatographic resins are easy to use and eliminate the generation of contaminated liquid organic waste.« less

  2. Optical micromachined ultrasound transducers (OMUT)--a new approach for high-frequency transducers.

    PubMed

    Tadayon, Mohammad Amin; Ashkenazi, Shai

    2013-09-01

    The sensitivity and reliability of piezoelectric ultrasound transducers severely degrade in applications requiring high frequency and small element size. Alternative technologies such as capacitive micromachined ultrasound transducers (CMUT) and optical sensing and generation of ultrasound have been proposed and studied for several decades. In this paper, we present a new type of device based on optical micromachined ultrasound transducer (OMUT) technology. OMUTs rely on microfabrication techniques to construct micrometerscale air cavities capped by an elastic membrane. A modified photoresist bonding process has been developed to facilitate the fabrication of these devices. We will describe the design, fabrication, and testing of prototype OMUT devices which implement a receive-only function. Future design modifications are proposed for incorporating complete transmit¿receive functionality in a single element.

  3. Analysis of genetically modified organisms by pyrosequencing on a portable photodiode-based bioluminescence sequencer.

    PubMed

    Song, Qinxin; Wei, Guijiang; Zhou, Guohua

    2014-07-01

    A portable bioluminescence analyser for detecting the DNA sequence of genetically modified organisms (GMOs) was developed by using a photodiode (PD) array. Pyrosequencing on eight genes (zSSIIb, Bt11 and Bt176 gene of genetically modified maize; Lectin, 35S-CTP4, CP4EPSPS, CaMV35S promoter and NOS terminator of the genetically modified Roundup ready soya) was successfully detected with this instrument. The corresponding limit of detection (LOD) was 0.01% with 35 PCR cycles. The maize and soya available from three different provenances in China were detected. The results indicate that pyrosequencing using the small size of the detector is a simple, inexpensive, and reliable way in a farm/field test of GMO analysis. Copyright © 2014 Elsevier Ltd. All rights reserved.

  4. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sidlauskas, D.P.

    A new type of biometric identifier which utilizes hand outline measurements made in three dimensions is described. This device uses solid state imaging with no moving parts. The important characteristics of accuracy, speed, user tolerability, small template size, low power, portability and reliability are discussed. A complete stand-alone biometric access control station with sufficient memory for 10,000 users and weighing less than 10 pounds has been built and tested. A test was conducted involving daily use by 112 users over a seven week period during which over 6300 access attempts were made. The single try equal error rate was foundmore » to be 0.4%. There were no false rejects when three tries were allowed before access was denied. Defeat with an artifact is difficult because the hand must be copied in all three dimensions.« less

  5. Small space station electrical power system design concepts

    NASA Technical Reports Server (NTRS)

    Jones, G. M.; Mercer, L. N.

    1976-01-01

    A small manned facility, i.e., a small space station, placed in earth orbit by the Shuttle transportation system would be a viable, cost effective addition to the basic Shuttle system to provide many opportunities for R&D programs, particularly in the area of earth applications. The small space station would have many similarities with Skylab. This paper presents design concepts for an electrical power system (EPS) for the small space station based on Skylab experience, in-house work at Marshall Space Flight Center, SEPS (Solar Electric Propulsion Stage) solar array development studies, and other studies sponsored by MSFC. The proposed EPS would be a solar array/secondary battery system. Design concepts expressed are based on maximizing system efficiency and five year operational reliability. Cost, weight, volume, and complexity considerations are inherent in the concepts presented. A small space station EPS based on these concepts would be highly efficient, reliable, and relatively inexpensive.

  6. Growth and ontogeny of the tapeworm Schistocephalus solidus in its copepod first host affects performance in its stickleback second intermediate host

    PubMed Central

    2012-01-01

    Background For parasites with complex life cycles, size at transmission can impact performance in the next host, thereby coupling parasite phenotypes in the two consecutive hosts. However, a handful of studies with parasites, and numerous studies with free-living, complex-life-cycle animals, have found that larval size correlates poorly with fitness under particular conditions, implying that other traits, such as physiological or ontogenetic variation, may predict fitness more reliably. Using the tapeworm Schistocephalus solidus, we evaluated how parasite size, age, and ontogeny in the copepod first host interact to determine performance in the stickleback second host. Methods We raised infected copepods under two feeding treatments (to manipulate parasite growth), and then exposed fish to worms of two different ages (to manipulate parasite ontogeny). We assessed how growth and ontogeny in copepods affected three measures of fitness in fish: infection probability, growth rate, and energy storage. Results Our main, novel finding is that the increase in fitness (infection probability and growth in fish) with larval size and age observed in previous studies on S. solidus seems to be largely mediated by ontogenetic variation. Worms that developed rapidly (had a cercomer after 9 days in copepods) were able to infect fish at an earlier age, and they grew to larger sizes with larger energy reserves in fish. Infection probability in fish increased with larval size chiefly in young worms, when size and ontogeny are positively correlated, but not in older worms that had essentially completed their larval development in copepods. Conclusions Transmission to sticklebacks as a small, not-yet-fully developed larva has clear costs for S. solidus, but it remains unclear what prevents the evolution of faster growth and development in this species. PMID:22564512

  7. Detecting long-term growth trends using tree rings: a critical evaluation of methods.

    PubMed

    Peters, Richard L; Groenendijk, Peter; Vlam, Mart; Zuidema, Pieter A

    2015-05-01

    Tree-ring analysis is often used to assess long-term trends in tree growth. A variety of growth-trend detection methods (GDMs) exist to disentangle age/size trends in growth from long-term growth changes. However, these detrending methods strongly differ in approach, with possible implications for their output. Here, we critically evaluate the consistency, sensitivity, reliability and accuracy of four most widely used GDMs: conservative detrending (CD) applies mathematical functions to correct for decreasing ring widths with age; basal area correction (BAC) transforms diameter into basal area growth; regional curve standardization (RCS) detrends individual tree-ring series using average age/size trends; and size class isolation (SCI) calculates growth trends within separate size classes. First, we evaluated whether these GDMs produce consistent results applied to an empirical tree-ring data set of Melia azedarach, a tropical tree species from Thailand. Three GDMs yielded similar results - a growth decline over time - but the widely used CD method did not detect any change. Second, we assessed the sensitivity (probability of correct growth-trend detection), reliability (100% minus probability of detecting false trends) and accuracy (whether the strength of imposed trends is correctly detected) of these GDMs, by applying them to simulated growth trajectories with different imposed trends: no trend, strong trends (-6% and +6% change per decade) and weak trends (-2%, +2%). All methods except CD, showed high sensitivity, reliability and accuracy to detect strong imposed trends. However, these were considerably lower in the weak or no-trend scenarios. BAC showed good sensitivity and accuracy, but low reliability, indicating uncertainty of trend detection using this method. Our study reveals that the choice of GDM influences results of growth-trend studies. We recommend applying multiple methods when analysing trends and encourage performing sensitivity and reliability analysis. Finally, we recommend SCI and RCS, as these methods showed highest reliability to detect long-term growth trends. © 2014 John Wiley & Sons Ltd.

  8. The Small Nuclear Genomes of Selaginella Are Associated with a Low Rate of Genome Size Evolution.

    PubMed

    Baniaga, Anthony E; Arrigo, Nils; Barker, Michael S

    2016-06-03

    The haploid nuclear genome size (1C DNA) of vascular land plants varies over several orders of magnitude. Much of this observed diversity in genome size is due to the proliferation and deletion of transposable elements. To date, all vascular land plant lineages with extremely small nuclear genomes represent recently derived states, having ancestors with much larger genome sizes. The Selaginellaceae represent an ancient lineage with extremely small genomes. It is unclear how small nuclear genomes evolved in Selaginella We compared the rates of nuclear genome size evolution in Selaginella and major vascular plant clades in a comparative phylogenetic framework. For the analyses, we collected 29 new flow cytometry estimates of haploid genome size in Selaginella to augment publicly available data. Selaginella possess some of the smallest known haploid nuclear genome sizes, as well as the lowest rate of genome size evolution observed across all vascular land plants included in our analyses. Additionally, our analyses provide strong support for a history of haploid nuclear genome size stasis in Selaginella Our results indicate that Selaginella, similar to other early diverging lineages of vascular land plants, has relatively low rates of genome size evolution. Further, our analyses highlight that a rapid transition to a small genome size is only one route to an extremely small genome. © The Author 2016. Published by Oxford University Press on behalf of the Society for Molecular Biology and Evolution.

  9. Design and Scheduling of Microgrids using Benders Decomposition

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nagarajan, Adarsh; Ayyanar, Raja

    2016-11-21

    The distribution feeder laterals in a distribution feeder with relatively high PV generation as compared to the load can be operated as microgrids to achieve reliability, power quality and economic benefits. However, renewable resources are intermittent and stochastic in nature. A novel approach for sizing and scheduling an energy storage system and microturbine for reliable operation of microgrids is proposed. The size and schedule of an energy storage system and microturbine are determined using Benders' decomposition, considering PV generation as a stochastic resource.

  10. Evaluating test-retest reliability in patient-reported outcome measures for older people: A systematic review.

    PubMed

    Park, Myung Sook; Kang, Kyung Ja; Jang, Sun Joo; Lee, Joo Yun; Chang, Sun Ju

    2018-03-01

    This study aimed to evaluate the components of test-retest reliability including time interval, sample size, and statistical methods used in patient-reported outcome measures in older people and to provide suggestions on the methodology for calculating test-retest reliability for patient-reported outcomes in older people. This was a systematic literature review. MEDLINE, Embase, CINAHL, and PsycINFO were searched from January 1, 2000 to August 10, 2017 by an information specialist. This systematic review was guided by both the Preferred Reporting Items for Systematic Reviews and Meta-Analyses checklist and the guideline for systematic review published by the National Evidence-based Healthcare Collaborating Agency in Korea. The methodological quality was assessed by the Consensus-based Standards for the selection of health Measurement Instruments checklist box B. Ninety-five out of 12,641 studies were selected for the analysis. The median time interval for test-retest reliability was 14days, and the ratio of sample size for test-retest reliability to the number of items in each measure ranged from 1:1 to 1:4. The most frequently used statistical methods for continuous scores was intraclass correlation coefficients (ICCs). Among the 63 studies that used ICCs, 21 studies presented models for ICC calculations and 30 studies reported 95% confidence intervals of the ICCs. Additional analyses using 17 studies that reported a strong ICC (>0.09) showed that the mean time interval was 12.88days and the mean ratio of the number of items to sample size was 1:5.37. When researchers plan to assess the test-retest reliability of patient-reported outcome measures for older people, they need to consider an adequate time interval of approximately 13days and the sample size of about 5 times the number of items. Particularly, statistical methods should not only be selected based on the types of scores of the patient-reported outcome measures, but should also be described clearly in the studies that report the results of test-retest reliability. Copyright © 2017 Elsevier Ltd. All rights reserved.

  11. Ontogenetic prey size selection in snakes: predator size and functional limitations to handling minimum prey sizes.

    PubMed

    Hampton, Paul M

    2018-02-01

    As body size increases, some predators eliminate small prey from their diet exhibiting an ontogenetic shift toward larger prey. In contrast, some predators show a telescoping pattern of prey size in which both large and small prey are consumed with increasing predator size. To explore a functional explanation for the two feeding patterns, I examined feeding effort as both handling time and number of upper jaw movements during ingestion of fish of consistent size. I used a range of body sizes from two snake species that exhibit ontogenetic shifts in prey size (Nerodia fasciata and N. rhombifer) and a species that exhibits telescoping prey size with increased body size (Thamnophis proximus). For the two Nerodia species, individuals with small or large heads exhibited greater difficulty in feeding effort compared to snakes of intermediate size. However, for T. proximus measures of feeding effort were negatively correlated with head length and snout-vent length (SVL). These data indicate that ontogenetic shifters of prey size develop trophic morphology large enough that feeding effort increases for disproportionately small prey. I also compared changes in body size among the two diet strategies for active foraging snake species using data gleaned from the literature to determine if increased change in body size and thereby feeding morphology is observable in snakes regardless of prey type or foraging habitat. Of the 30 species sampled from literature, snakes that exhibit ontogenetic shifts in prey size have a greater magnitude of change in SVL than species that have telescoping prey size patterns. Based upon the results of the two data sets above, I conclude that ontogenetic shifts away from small prey occur in snakes due, in part, to growth of body size and feeding structures beyond what is efficient for handling small prey. Copyright © 2017. Published by Elsevier GmbH.

  12. Status report: Implementation of gas measurements at the MAMS 14C AMS facility in Mannheim, Germany

    NASA Astrophysics Data System (ADS)

    Hoffmann, Helene; Friedrich, Ronny; Kromer, Bernd; Fahrni, Simon

    2017-11-01

    By implementing a Gas Interface System (GIS), CO2 gas measurements for radiocarbon dating of small environmental samples (<100 μgC) have been established at the MICADAS (Mini Carbon Dating System) AMS instrument in Mannheim, Germany. The system performance has been optimized and tested with respect to stability and ion yield by repeated blank and standard measurements for sample sizes down to 3 μgC. The highest 12C- low-energy (LE) ion currents, typically reaching 8-15 μA, could be achieved for a mixing ratio of 4% CO2 in Helium, resulting in relative counting errors of 1-2% for samples larger than 10 μgC and 3-7% for sample sizes below 10 μgC. The average count rate was ca. 500 counts per microgram C for OxII standard material. The blank is on the order of 35,000-40,000 radiocarbon years, which is comparable to similar systems. The complete setup thus enables reliable dating for most environmental samples (>3 μgC).

  13. Does size matter? Statistical limits of paleomagnetic field reconstruction from small rock specimens

    NASA Astrophysics Data System (ADS)

    Berndt, Thomas; Muxworthy, Adrian R.; Fabian, Karl

    2016-01-01

    As samples of ever decreasing sizes are being studied paleomagnetically, care has to be taken that the underlying assumptions of statistical thermodynamics (Maxwell-Boltzmann statistics) are being met. Here we determine how many grains and how large a magnetic moment a sample needs to have to be able to accurately record an ambient field. It is found that for samples with a thermoremanent magnetic moment larger than 10-11Am2 the assumption of a sufficiently large number of grains is usually given. Standard 25 mm diameter paleomagnetic samples usually contain enough magnetic grains such that statistical errors are negligible, but "single silicate crystal" works on, for example, zircon, plagioclase, and olivine crystals are approaching the limits of what is physically possible, leading to statistic errors in both the angular deviation and paleointensity that are comparable to other sources of error. The reliability of nanopaleomagnetic imaging techniques capable of resolving individual grains (used, for example, to study the cloudy zone in meteorites), however, is questionable due to the limited area of the material covered.

  14. Exploring exoplanet populations with NASA's Kepler Mission

    NASA Astrophysics Data System (ADS)

    Batalha, Natalie M.

    2014-09-01

    The Kepler Mission is exploring the diversity of planets and planetary systems. Its legacy will be a catalog of discoveries sufficient for computing planet occurrence rates as a function of size, orbital period, star type, and insolation flux. The mission has made significant progress toward achieving that goal. Over 3,500 transiting exoplanets have been identified from the analysis of the first 3 y of data, 100 planets of which are in the habitable zone. The catalog has a high reliability rate (85-90% averaged over the period/radius plane), which is improving as follow-up observations continue. Dynamical (e.g., velocimetry and transit timing) and statistical methods have confirmed and characterized hundreds of planets over a large range of sizes and compositions for both single- and multiple-star systems. Population studies suggest that planets abound in our galaxy and that small planets are particularly frequent. Here, I report on the progress Kepler has made measuring the prevalence of exoplanets orbiting within one astronomical unit of their host stars in support of the National Aeronautics and Space Administration's long-term goal of finding habitable environments beyond the solar system.

  15. Magnetic Suspension and Balance Systems: A Selected, Annotated Bibliography

    NASA Technical Reports Server (NTRS)

    Tuttle Marie H.; Kilgore, Robert A.; Boyden, Richmond P.

    1983-01-01

    This publication, containing 206 entries, supersedes an earlier bibliography, NASA TM-80225 (April 1980). Citations for 18 documents have been added in this updated version. Most of the additions report results of recent studies aimed at increasing the research capabilities of magnetic suspension and balance systems, e.g., increasing force and torque capability, increasing angle of attack capability, and increasing overall system reliability. Some of the additions address the problem of scaling from the relatively small size of existing systems to much larger sizes. The purpose of this bibliography is to provide an up-to-date list of publications that might be helpful to persons interested in magnetic suspension and balance systems for use in wind tunnels. The arrangement is generally chronological by date of publication. However, papers presented at conferences or meetings are placed under dates of presentation. The numbers assigned to many of the citations have been changed from those used in the previous bibliography. This has been done in order to allow outdated citations to be removed and some recently discovered older works to be included in their proper chronological order.

  16. More reliable inference for the dissimilarity index of segregation

    PubMed Central

    Allen, Rebecca; Burgess, Simon; Davidson, Russell; Windmeijer, Frank

    2015-01-01

    Summary The most widely used measure of segregation is the so‐called dissimilarity index. It is now well understood that this measure also reflects randomness in the allocation of individuals to units (i.e. it measures deviations from evenness, not deviations from randomness). This leads to potentially large values of the segregation index when unit sizes and/or minority proportions are small, even if there is no underlying systematic segregation. Our response to this is to produce adjustments to the index, based on an underlying statistical model. We specify the assignment problem in a very general way, with differences in conditional assignment probabilities underlying the resulting segregation. From this, we derive a likelihood ratio test for the presence of any systematic segregation, and bias adjustments to the dissimilarity index. We further develop the asymptotic distribution theory for testing hypotheses concerning the magnitude of the segregation index and show that the use of bootstrap methods can improve the size and power properties of test procedures considerably. We illustrate these methods by comparing dissimilarity indices across school districts in England to measure social segregation. PMID:27774035

  17. Larger cages with housing unit environment enrichment improve the welfare of marmosets.

    PubMed

    Yoshimoto, Takuro; Takahashi, Eiki; Yamashita, Shunji; Ohara, Kiichi; Niimi, Kimie

    2018-02-09

    The provision of adequate space for laboratory animals is essential not only for good welfare but accurate studies. For example, housing conditions for primates used in biomedical research may negatively affect welfare and thus the reliability of findings. In common marmosets (Callithrix jacchus), an appropriate cage size enables a socially harmonious family environment and optimizes reproductive potential. In this study, we investigated the effects of cage size on body weight (BW), behavior, and nursing succession in the common marmoset. Large cages (LCs) with environment enrichment led to an increase in BW while small cages (SCs) caused stereotypic behaviors that were not observed in LCs. In addition, the BW of infants increased with aging in LCs. Our findings indicate that the welfare of marmosets was enhanced by living in LCs. Research on non-human primates is essential for understanding the human brain and developing knowledge-based strategies for the diagnosis and treatment of psychiatric and neurological disorders. Thus, the present findings are important because they indicate that different cages may influence emotional and behavioral phenotypes.

  18. Morphological cladistic analysis of eight popular Olive (Olea europaea L.) cultivars grown in Saudi Arabia using Numerical Taxonomic System for personal computer to detect phyletic relationship and their proximate fruit composition

    PubMed Central

    Al-Ruqaie, I.; Al-Khalifah, N.S.; Shanavaskhan, A.E.

    2015-01-01

    Varietal identification of olives is an intrinsic and empirical exercise owing to the large number of synonyms and homonyms, intensive exchange of genotypes, presence of varietal clones and lack of proper certification in nurseries. A comparative study of morphological characters of eight olive cultivars grown in Saudi Arabia was carried out and analyzed using NTSYSpc (Numerical Taxonomy System for personal computer) system segregated smaller fruits in one clade and the rest in two clades. Koroneiki, a Greek cultivar with a small sized fruit shared arm with Spanish variety Arbosana. Morphologic analysis using NTSYSpc revealed that biometrics of leaves, fruits and seeds are reliable morphologic characters to distinguish between varieties, except for a few morphologically very similar olive cultivars. The proximate analysis showed significant variations in the protein, fiber, crude fat, ash and moisture content of different cultivars. The study also showed that neither the size of fruit nor the fruit pulp thickness is a limiting factor determining crude fat content of olives. PMID:26858547

  19. A review and meta-analysis of age-based stereotype threat: negative stereotypes, not facts, do the damage.

    PubMed

    Lamont, Ruth A; Swift, Hannah J; Abrams, Dominic

    2015-03-01

    Stereotype threat effects arise when an individual feels at risk of confirming a negative stereotype about their group and consequently underperforms on stereotype relevant tasks (Steele, 2010). Among older people, underperformance across cognitive and physical tasks is hypothesized to result from age-based stereotype threat (ABST) because of negative age-stereotypes regarding older adults' competence. The present review and meta-analyses examine 22 published and 10 unpublished articles, including 82 effect sizes (N = 3882) investigating ABST on older people's (Mage = 69.5) performance. The analysis revealed a significant small-to-medium effect of ABST (d = .28) and important moderators of the effect size. Specifically, older adults are more vulnerable to ABST when (a) stereotype-based rather than fact-based manipulations are used (d = .52); (b) when performance is tested using cognitive measures (d = .36); and (c) occurs reliably when the dependent variable is measured proximally to the manipulation. The review raises important theoretical and methodological issues, and areas for future research. (c) 2015 APA, all rights reserved).

  20. Continuous video coherence computing model for detecting scene boundaries

    NASA Astrophysics Data System (ADS)

    Kang, Hang-Bong

    2001-07-01

    The scene boundary detection is important in the semantic understanding of video data and is usually determined by coherence between shots. To measure the coherence, two approaches have been proposed. One is a discrete approach and the other one is a continuous approach. In this paper, we use the continuous approach and propose some modifications on the causal First-In-First-Out(FIFO) short-term memory-based model. One modification is that we allow dynamic memory size in computing coherence reliably regardless of the size of each shot. Another modification is that some shots can be removed from the memory buffer not by the FIFO rule. These removed shots have no or small foreground objects. Using this model, we detect scene boundaries by computing shot coherence. In computing coherence, we add one new term which is the number of intermediate shots between two comparing shots because the effect of intermediate shots is important in computing shot recall. In addition, we also consider shot activity because this is important to reflect human perception. We experiment our computing model on different genres of videos and have obtained reasonable results.

Top