Sample records for reliability studies conducted

  1. Reliability studies of diagnostic methods in Indian traditional Ayurveda medicine: An overview

    PubMed Central

    Kurande, Vrinda Hitendra; Waagepetersen, Rasmus; Toft, Egon; Prasad, Ramjee

    2013-01-01

    Recently, a need to develop supportive new scientific evidence for contemporary Ayurveda has emerged. One of the research objectives is an assessment of the reliability of diagnoses and treatment. Reliability is a quantitative measure of consistency. It is a crucial issue in classification (such as prakriti classification), method development (pulse diagnosis), quality assurance for diagnosis and treatment and in the conduct of clinical studies. Several reliability studies are conducted in western medicine. The investigation of the reliability of traditional Chinese, Japanese and Sasang medicine diagnoses is in the formative stage. However, reliability studies in Ayurveda are in the preliminary stage. In this paper, examples are provided to illustrate relevant concepts of reliability studies of diagnostic methods and their implication in practice, education, and training. An introduction to reliability estimates and different study designs and statistical analysis is given for future studies in Ayurveda. PMID:23930037

  2. Generalizability and decision studies to inform observational and experimental research in classroom settings.

    PubMed

    Bottema-Beutel, Kristen; Lloyd, Blair; Carter, Erik W; Asmus, Jennifer M

    2014-11-01

    Attaining reliable estimates of observational measures can be challenging in school and classroom settings, as behavior can be influenced by multiple contextual factors. Generalizability (G) studies can enable researchers to estimate the reliability of observational data, and decision (D) studies can inform how many observation sessions are necessary to achieve a criterion level of reliability. We conducted G and D studies using observational data from a randomized control trial focusing on social and academic participation of students with severe disabilities in inclusive secondary classrooms. Results highlight the importance of anchoring observational decisions to reliability estimates from existing or pilot data sets. We outline steps for conducting G and D studies and address options when reliability estimates are lower than desired.

  3. The Balanced Inventory of Desirable Responding (BIDR): A Reliability Generalization Study

    ERIC Educational Resources Information Center

    Li, Andrew; Bagger, Jessica

    2007-01-01

    The Balanced Inventory of Desirable Responding (BIDR) is one of the most widely used social desirability scales. The authors conducted a reliability generalization study to examine the typical reliability coefficients of BIDR scores and explored factors that explained the variability of reliability estimates across studies. The results indicated…

  4. Reliability and Probabilistic Risk Assessment - How They Play Together

    NASA Technical Reports Server (NTRS)

    Safie, Fayssal M.; Stutts, Richard G.; Zhaofeng, Huang

    2015-01-01

    PRA methodology is one of the probabilistic analysis methods that NASA brought from the nuclear industry to assess the risk of LOM, LOV and LOC for launch vehicles. PRA is a system scenario based risk assessment that uses a combination of fault trees, event trees, event sequence diagrams, and probability and statistical data to analyze the risk of a system, a process, or an activity. It is a process designed to answer three basic questions: What can go wrong? How likely is it? What is the severity of the degradation? Since 1986, NASA, along with industry partners, has conducted a number of PRA studies to predict the overall launch vehicles risks. Planning Research Corporation conducted the first of these studies in 1988. In 1995, Science Applications International Corporation (SAIC) conducted a comprehensive PRA study. In July 1996, NASA conducted a two-year study (October 1996 - September 1998) to develop a model that provided the overall Space Shuttle risk and estimates of risk changes due to proposed Space Shuttle upgrades. After the Columbia accident, NASA conducted a PRA on the Shuttle External Tank (ET) foam. This study was the most focused and extensive risk assessment that NASA has conducted in recent years. It used a dynamic, physics-based, integrated system analysis approach to understand the integrated system risk due to ET foam loss in flight. Most recently, a PRA for Ares I launch vehicle has been performed in support of the Constellation program. Reliability, on the other hand, addresses the loss of functions. In a broader sense, reliability engineering is a discipline that involves the application of engineering principles to the design and processing of products, both hardware and software, for meeting product reliability requirements or goals. It is a very broad design-support discipline. It has important interfaces with many other engineering disciplines. Reliability as a figure of merit (i.e. the metric) is the probability that an item will perform its intended function(s) for a specified mission profile. In general, the reliability metric can be calculated through the analyses using reliability demonstration and reliability prediction methodologies. Reliability analysis is very critical for understanding component failure mechanisms and in identifying reliability critical design and process drivers. The following sections discuss the PRA process and reliability engineering in detail and provide an application where reliability analysis and PRA were jointly used in a complementary manner to support a Space Shuttle flight risk assessment.

  5. Expanding Reliability Generalization Methods with KR-21 Estimates: An RG Study of the Coopersmith Self-Esteem Inventory.

    ERIC Educational Resources Information Center

    Lane, Ginny G.; White, Amy E.; Henson, Robin K.

    2002-01-01

    Conducted a reliability generalizability study on the Coopersmith Self-Esteem Inventory (CSEI; S. Coopersmith, 1967) to examine the variability of reliability estimates across studies and to identify study characteristics that may predict this variability. Results show that reliability for CSEI scores can vary considerably, especially at the…

  6. Score Reliability: A Retrospective Look Back at 12 Years of Reliability Generalization Studies

    ERIC Educational Resources Information Center

    Vacha-Haase, Tammi; Thompson, Bruce

    2011-01-01

    The present study was conducted to characterize (a) the features of the thousands of primary reports synthesized in 47 reliability generalization (RG) measurement meta-analysis studies and (b) typical methodological practice within the RG literature to date. With respect to the treatment of score reliability in the literature, in an astounding…

  7. A Reliability Generalization Study of the Marlowe-Crowne Social Desirability Scale.

    ERIC Educational Resources Information Center

    Beretvas, S, Natasha; Meyers, Jason L.; Leite, Walter L.

    2002-01-01

    Conducted a reliability generalization study of the Marlowe-Crowne Social Desirability Scale (D. Crowne and D. Marlowe, 1960). Analysis of 93 studies show that the predicted score reliability for male adolescents was 0.53, and reliability for men's responses was lower than for women's. Discusses the need for further analysis of the scale. (SLD)

  8. Characterizing Measurement Error in Test Scores across Studies: A Tutorial on Conducting "Reliability Generalization" Analyses.

    ERIC Educational Resources Information Center

    Henson, Robin K.; Thompson, Bruce

    Given the potential value of reliability generalization (RG) studies in the development of cumulative psychometric knowledge, the purpose of this paper is to provide a tutorial on how to conduct such studies and to serve as a guide for researchers wishing to use this methodology. After some brief comments on classical test theory, the paper…

  9. Adaptation of the ToxRTool to Assess the Reliability of Toxicology Studies Conducted with Genetically Modified Crops and Implications for Future Safety Testing.

    PubMed

    Koch, Michael S; DeSesso, John M; Williams, Amy Lavin; Michalek, Suzanne; Hammond, Bruce

    2016-01-01

    To determine the reliability of food safety studies carried out in rodents with genetically modified (GM) crops, a Food Safety Study Reliability Tool (FSSRTool) was adapted from the European Centre for the Validation of Alternative Methods' (ECVAM) ToxRTool. Reliability was defined as the inherent quality of the study with regard to use of standardized testing methodology, full documentation of experimental procedures and results, and the plausibility of the findings. Codex guidelines for GM crop safety evaluations indicate toxicology studies are not needed when comparability of the GM crop to its conventional counterpart has been demonstrated. This guidance notwithstanding, animal feeding studies have routinely been conducted with GM crops, but their conclusions on safety are not always consistent. To accurately evaluate potential risks from GM crops, risk assessors need clearly interpretable results from reliable studies. The development of the FSSRTool, which provides the user with a means of assessing the reliability of a toxicology study to inform risk assessment, is discussed. Its application to the body of literature on GM crop food safety studies demonstrates that reliable studies report no toxicologically relevant differences between rodents fed GM crops or their non-GM comparators.

  10. Analyzing the Reliability of the easyCBM Reading Comprehension Measures: Grade 5. Technical Report #1204

    ERIC Educational Resources Information Center

    Park, Bitnara Jasmine; Irvin, P. Shawn; Lai, Cheng-Fei; Alonzo, Julie; Tindal, Gerald

    2012-01-01

    In this technical report, we present the results of a reliability study of the fifth-grade multiple choice reading comprehension measures available on the easyCBM learning system conducted in the spring of 2011. Analyses include split-half reliability, alternate form reliability, person and item reliability as derived from Rasch analysis,…

  11. Analyzing the Reliability of the easyCBM Reading Comprehension Measures: Grade 2. Technical Report #1201

    ERIC Educational Resources Information Center

    Lai, Cheng-Fei; Irvin, P. Shawn; Alonzo, Julie; Park, Bitnara Jasmine; Tindal, Gerald

    2012-01-01

    In this technical report, we present the results of a reliability study of the second-grade multiple choice reading comprehension measures available on the easyCBM learning system conducted in the spring of 2011. Analyses include split-half reliability, alternate form reliability, person and item reliability as derived from Rasch analysis,…

  12. Analyzing the Reliability of the easyCBM Reading Comprehension Measures: Grade 4. Technical Report #1203

    ERIC Educational Resources Information Center

    Park, Bitnara Jasmine; Irvin, P. Shawn; Alonzo, Julie; Lai, Cheng-Fei; Tindal, Gerald

    2012-01-01

    In this technical report, we present the results of a reliability study of the fourth-grade multiple choice reading comprehension measures available on the easyCBM learning system conducted in the spring of 2011. Analyses include split-half reliability, alternate form reliability, person and item reliability as derived from Rasch analysis,…

  13. Analyzing the Reliability of the easyCBM Reading Comprehension Measures: Grade 6. Technical Report #1205

    ERIC Educational Resources Information Center

    Irvin, P. Shawn; Alonzo, Julie; Park, Bitnara Jasmine; Lai, Cheng-Fei; Tindal, Gerald

    2012-01-01

    In this technical report, we present the results of a reliability study of the sixth-grade multiple choice reading comprehension measures available on the easyCBM learning system conducted in the spring of 2011. Analyses include split-half reliability, alternate form reliability, person and item reliability as derived from Rasch analysis,…

  14. Analyzing the Reliability of the easyCBM Reading Comprehension Measures: Grade 7. Technical Report #1206

    ERIC Educational Resources Information Center

    Irvin, P. Shawn; Alonzo, Julie; Lai, Cheng-Fei; Park, Bitnara Jasmine; Tindal, Gerald

    2012-01-01

    In this technical report, we present the results of a reliability study of the seventh-grade multiple choice reading comprehension measures available on the easyCBM learning system conducted in the spring of 2011. Analyses include split-half reliability, alternate form reliability, person and item reliability as derived from Rasch analysis,…

  15. Analyzing the Reliability of the easyCBM Reading Comprehension Measures: Grade 3. Technical Report #1202

    ERIC Educational Resources Information Center

    Lai, Cheng-Fei; Irvin, P. Shawn; Park, Bitnara Jasmine; Alonzo, Julie; Tindal, Gerald

    2012-01-01

    In this technical report, we present the results of a reliability study of the third-grade multiple choice reading comprehension measures available on the easyCBM learning system conducted in the spring of 2011. Analyses include split-half reliability, alternate form reliability, person and item reliability as derived from Rasch analysis,…

  16. Reliability Generalization of Scores on the Spielberger State-Trait Anxiety Inventory.

    ERIC Educational Resources Information Center

    Barnes, Laura L. B.; Harp, Diane; Jung, Woo Sik

    2002-01-01

    Conducted a reliability generalization study for the State-Trait Anxiety Inventory (C. Spielberger, 1983) by reviewing and classifying 816 research articles. Average reliability coefficients were acceptable for both internal consistency and test-retest reliability, but variation was present among the estimates. Other differences are discussed.…

  17. Inter-rater agreement in evaluation of disability: systematic review of reproducibility studies

    PubMed Central

    Barth, Jürgen; de Boer, Wout E L; Busse, Jason W; Hoving, Jan L; Kedzia, Sarah; Couban, Rachel; Fischer, Katrin; von Allmen, David Y; Spanjer, Jerry

    2017-01-01

    Objectives To explore agreement among healthcare professionals assessing eligibility for work disability benefits. Design Systematic review and narrative synthesis of reproducibility studies. Data sources Medline, Embase, and PsycINFO searched up to 16 March 2016, without language restrictions, and review of bibliographies of included studies. Eligibility criteria Observational studies investigating reproducibility among healthcare professionals performing disability evaluations using a global rating of working capacity and reporting inter-rater reliability by a statistical measure or descriptively. Studies could be conducted in insurance settings, where decisions on ability to work include normative judgments based on legal considerations, or in research settings, where decisions on ability to work disregard normative considerations.Teams of paired reviewers identified eligible studies, appraised their methodological quality and generalisability, and abstracted results with pretested forms. As heterogeneity of research designs and findings impeded a quantitative analysis, a descriptive synthesis stratified by setting (insurance or research) was performed. Results From 4562 references, 101 full text articles were reviewed. Of these, 16 studies conducted in an insurance setting and seven in a research setting, performed in 12 countries, met the inclusion criteria. Studies in the insurance setting were conducted with medical experts assessing claimants who were actual disability claimants or played by actors, hypothetical cases, or short written scenarios. Conditions were mental (n=6, 38%), musculoskeletal (n=4, 25%), or mixed (n=6, 38%). Applicability of findings from studies conducted in an insurance setting to real life evaluations ranged from generalisable (n=7, 44%) and probably generalisable (n=3, 19%) to probably not generalisable (n=6, 37%). Median inter-rater reliability among experts was 0.45 (range intraclass correlation coefficient 0.86 to κ−0.10). Inter-rater reliability was poor in six studies (37%) and excellent in only two (13%). This contrasts with studies conducted in the research setting, where the median inter-rater reliability was 0.76 (range 0.91-0.53), and 71% (5/7) studies achieved excellent inter-rater reliability. Reliability between assessing professionals was higher when the evaluation was guided by a standardised instrument (23 studies, P=0.006). No such association was detected for subjective or chronic health conditions or the studies’ generalisability to real world evaluation of disability (P=0.46, 0.45, and 0.65, respectively). Conclusions Despite their common use and far reaching consequences for workers claiming disabling injury or illness, research on the reliability of medical evaluations of disability for work is limited and indicates high variation in judgments among assessing professionals. Standardising the evaluation process could improve reliability. Development and testing of instruments and structured approaches to improve reliability in evaluation of disability are urgently needed. PMID:28122727

  18. Validity and Reliability of the Academic Resilience Scale in Turkish High School

    ERIC Educational Resources Information Center

    Kapikiran, Sahin

    2012-01-01

    The present study aims to determine the validity and reliability of the academic resilience scale in Turkish high school. The participances of the study includes 378 high school students in total (192 female and 186 male). A set of analyses were conducted in order to determine the validity and reliability of the study. Firstly, both exploratory…

  19. Evaluation of tools used to measure calcium and/or dairy consumption in adults.

    PubMed

    Magarey, Anthea; Baulderstone, Lauren; Yaxley, Alison; Markow, Kylie; Miller, Michelle

    2015-05-01

    To identify and critique tools for the assessment of Ca and/or dairy intake in adults, in order to ascertain the most accurate and reliable tools available. A systematic review of the literature was conducted using defined inclusion and exclusion criteria. Articles reporting on originally developed tools or testing the reliability or validity of existing tools that measure Ca and/or dairy intake in adults were included. Author-defined criteria for reporting reliability and validity properties were applied. Studies conducted in Western countries. Adults. Thirty papers, utilising thirty-six tools assessing intake of dairy, Ca or both, were identified. Reliability testing was conducted on only two dairy and five Ca tools, with results indicating that only one dairy and two Ca tools were reliable. Validity testing was conducted for all but four Ca-only tools. There was high reliance in validity testing on lower-order tests such as correlation and failure to differentiate between statistical and clinically meaningful differences. Results of the validity testing suggest one dairy and five Ca tools are valid. Thus one tool was considered both reliable and valid for the assessment of dairy intake and only two tools proved reliable and valid for the assessment of Ca intake. While several tools are reliable and valid, their application across adult populations is limited by the populations in which they were tested. These results indicate a need for tools that assess Ca and/or dairy intake in adults to be rigorously tested for reliability and validity.

  20. How to Make Reliable, Washable, and Wearable Textronic Devices

    PubMed Central

    Tao, Xuyuan; Koncar, Vladan; Huang, Tzu-Hao; Shen, Chien-Lung; Ko, Ya-Chi; Jou, Gwo-Tsuen

    2017-01-01

    In this paper, the washability of wearable textronic (textile-electronic) devices has been studied. Two different approaches aiming at designing, producing, and testing robust washable and reliable smart textile systems are presented. The common point of the two approaches is the use of flexible conductive PCB in order to interface the miniaturized rigid (traditional) electronic devices to conductive threads and tracks within the textile flexible fabric and to connect them to antenna, textile electrodes, sensors, actuators, etc. The first approach consists in the use of TPU films (thermoplastic polyurethane) that are deposited by the press under controlled temperature and pressure parameters in order to protect the conductive thread and electrical contacts. The washability of conductive threads and contact resistances between flexible PCB and conductive threads are tested. The second approach is focused on the protection of the whole system—composed of a rigid electronic device, flexible PCB, and textile substrate—by a barrier made of latex. Three types of prototypes were realized and washed. Their reliabilities are studied. PMID:28338607

  1. Validation of the Waterpipe Tolerance Questionnaire among Jordanian School-Going Adolescent Waterpipe Users

    PubMed Central

    Alzyoud, Sukaina; Veeranki, Sreenivas P.; Kheirallah, Khalid A.; Shotar, Ali M.; Pbert, Lori

    2016-01-01

    Introduction: Waterpipe use among adolescents has been increasing progressively. Yet no studies were reported to assess the validity and reliability of nicotine dependence scale. The current study aims to assess the validity and reliability of an Arabic version of the modified Waterpipe Tolerance Questionnaire WTQ among school-going adolescent waterpipe users. Methods: In a cross-sectional study conducted in Jordan, information on waterpipe use among 333 school-going adolescents aged 11-18 years was obtained using the Arabic version of the WTQ. An exploratory factor analysis and correlation matrices were conducted to assess validity and reliability of the WTQ. Results: The WTQ had a 0.73 alpha of internal consistency indicating moderate level of reliability. The scale showed multidimensionality with items loading on two factors, namely waterpipe consumption and morning smoking. Conclusion: This study report nicotine dependence level among school-going adolescents who identify themselves as waterpipe users using the WTQ. PMID:26383198

  2. Developing Scale for Determining the Social Participation Skills for Children and Analyzing Its Psychometric Characteristics

    ERIC Educational Resources Information Center

    Samanci, Osman; Ocakci, Ebru; Seçer, Ismail

    2018-01-01

    The purpose of this research is to conduct validity and reliability studies of the Scale for the Determining Social Participation for Children, developed to measure social participation skills of children aged 7-10 years. During the development of the scale, pilot schemes, validity analyzes, and reliability analyzes were conducted. In this…

  3. Inter-rater agreement in evaluation of disability: systematic review of reproducibility studies.

    PubMed

    Barth, Jürgen; de Boer, Wout E L; Busse, Jason W; Hoving, Jan L; Kedzia, Sarah; Couban, Rachel; Fischer, Katrin; von Allmen, David Y; Spanjer, Jerry; Kunz, Regina

    2017-01-25

     To explore agreement among healthcare professionals assessing eligibility for work disability benefits.  Systematic review and narrative synthesis of reproducibility studies.  Medline, Embase, and PsycINFO searched up to 16 March 2016, without language restrictions, and review of bibliographies of included studies.  Observational studies investigating reproducibility among healthcare professionals performing disability evaluations using a global rating of working capacity and reporting inter-rater reliability by a statistical measure or descriptively. Studies could be conducted in insurance settings, where decisions on ability to work include normative judgments based on legal considerations, or in research settings, where decisions on ability to work disregard normative considerations. : Teams of paired reviewers identified eligible studies, appraised their methodological quality and generalisability, and abstracted results with pretested forms. As heterogeneity of research designs and findings impeded a quantitative analysis, a descriptive synthesis stratified by setting (insurance or research) was performed.  From 4562 references, 101 full text articles were reviewed. Of these, 16 studies conducted in an insurance setting and seven in a research setting, performed in 12 countries, met the inclusion criteria. Studies in the insurance setting were conducted with medical experts assessing claimants who were actual disability claimants or played by actors, hypothetical cases, or short written scenarios. Conditions were mental (n=6, 38%), musculoskeletal (n=4, 25%), or mixed (n=6, 38%). Applicability of findings from studies conducted in an insurance setting to real life evaluations ranged from generalisable (n=7, 44%) and probably generalisable (n=3, 19%) to probably not generalisable (n=6, 37%). Median inter-rater reliability among experts was 0.45 (range intraclass correlation coefficient 0.86 to κ-0.10). Inter-rater reliability was poor in six studies (37%) and excellent in only two (13%). This contrasts with studies conducted in the research setting, where the median inter-rater reliability was 0.76 (range 0.91-0.53), and 71% (5/7) studies achieved excellent inter-rater reliability. Reliability between assessing professionals was higher when the evaluation was guided by a standardised instrument (23 studies, P=0.006). No such association was detected for subjective or chronic health conditions or the studies' generalisability to real world evaluation of disability (P=0.46, 0.45, and 0.65, respectively).  Despite their common use and far reaching consequences for workers claiming disabling injury or illness, research on the reliability of medical evaluations of disability for work is limited and indicates high variation in judgments among assessing professionals. Standardising the evaluation process could improve reliability. Development and testing of instruments and structured approaches to improve reliability in evaluation of disability are urgently needed. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  4. Reliability generalization study of the Yale-Brown Obsessive-Compulsive Scale for children and adolescents.

    PubMed

    López-Pina, José Antonio; Sánchez-Meca, Julio; López-López, José Antonio; Marín-Martínez, Fulgencio; Núñez-Núñez, Rosa Ma; Rosa-Alcázar, Ana I; Gómez-Conesa, Antonia; Ferrer-Requena, Josefa

    2015-01-01

    The Yale-Brown Obsessive-Compulsive Scale for children and adolescents (CY-BOCS) is a frequently applied test to assess obsessive-compulsive symptoms. We conducted a reliability generalization meta-analysis on the CY-BOCS to estimate the average reliability, search for reliability moderators, and propose a predictive model that researchers and clinicians can use to estimate the expected reliability of the CY-BOCS scores. A total of 47 studies reporting a reliability coefficient with the data at hand were included in the meta-analysis. The results showed good reliability and a large variability associated to the standard deviation of total scores and sample size.

  5. Reliability of Real-time Ultrasound Imaging for the Assessment of Trunk Stabilizer Muscles: A Systematic Review of the Literature.

    PubMed

    Taghipour, Morteza; Mohseni-Bandpei, Mohammad Ali; Behtash, Hamid; Abdollahi, Iraj; Rajabzadeh, Fatemeh; Pourahmadi, Mohammad Reza; Emami, Mahnaz

    2018-04-24

    Rehabilitative ultrasound (US) imaging is one of the popular methods for investigating muscle morphologic characteristics and dimensions in recent years. The reliability of this method has been investigated in different studies. As studies have been performed with different designs and quality, reported values of rehabilitative US have a wide range. The objective of this study was to systematically review the literature conducted on the reliability of rehabilitative US imaging for the assessment of deep abdominal and lumbar trunk muscle dimensions. The PubMed/MEDLINE, Scopus, Google Scholar, Science Direct, Embase, Physiotherapy Evidence, Ovid, and CINAHL databases were searched to identify original research articles conducted on the reliability of rehabilitative US imaging published from June 2007 to August 2017. The articles were qualitatively assessed; reliability data were extracted; and the methodological quality was evaluated by 2 independent reviewers. Of the 26 included studies, 16 were considered of high methodological quality. Except for 2 studies, all high-quality studies reported intraclass correlation coefficients (ICCs) for intra-rater reliability of 0.70 or greater. Also, ICCs reported for inter-rater reliability in high-quality studies were generally greater than 0.70. Among low-quality studies, reported ICCs ranged from 0.26 to 0.99 and 0.68 to 0.97 for intra- and inter-rater reliability, respectively. Also, the reported standard error of measurement and minimal detectable change for rehabilitative US were generally in an acceptable range. Generally, the results of the reviewed studies indicate that rehabilitative US imaging has good levels of both inter- and intra-rater reliability. © 2018 by the American Institute of Ultrasound in Medicine.

  6. Systematic Screening at the Middle School Level: Score Reliability and Validity of the Student Risk Screening Scale

    ERIC Educational Resources Information Center

    Lane, Kathleen Lynne; Parks, Robin J.; Kalberg, Jemma Robertson; Carter, Erik W.

    2007-01-01

    This article presents findings of two studies, one conducted with middle school students (n = 500) in a rural setting and a second conducted with middle school students (n = 528) in an urban setting, of the reliability and validity of the "Student Risk Screening Scale" (SRSS; Drummond, 1994). Results revealed high internal consistency, test-retest…

  7. Flexible organic TFT bio-signal amplifier using reliable chip component assembly process with conductive adhesive.

    PubMed

    Yoshimoto, Shusuke; Uemura, Takafumi; Akiyama, Mihoko; Ihara, Yoshihiro; Otake, Satoshi; Fujii, Tomoharu; Araki, Teppei; Sekitani, Tsuyoshi

    2017-07-01

    This paper presents a flexible organic thin-film transistor (OTFT) amplifier for bio-signal monitoring and presents the chip component assembly process. Using a conductive adhesive and a chip mounter, the chip components are mounted on a flexible film substrate, which has OTFT circuits. This study first investigates the assembly technique reliability for chip components on the flexible substrate. This study also specifically examines heart pulse wave monitoring conducted using the proposed flexible amplifier circuit and a flexible piezoelectric film. We connected the amplifier to a bluetooth device for a wearable device demonstration.

  8. Intersession reliability of fMRI activation for heat pain and motor tasks

    PubMed Central

    Quiton, Raimi L.; Keaser, Michael L.; Zhuo, Jiachen; Gullapalli, Rao P.; Greenspan, Joel D.

    2014-01-01

    As the practice of conducting longitudinal fMRI studies to assess mechanisms of pain-reducing interventions becomes more common, there is a great need to assess the test–retest reliability of the pain-related BOLD fMRI signal across repeated sessions. This study quantitatively evaluated the reliability of heat pain-related BOLD fMRI brain responses in healthy volunteers across 3 sessions conducted on separate days using two measures: (1) intraclass correlation coefficients (ICC) calculated based on signal amplitude and (2) spatial overlap. The ICC analysis of pain-related BOLD fMRI responses showed fair-to-moderate intersession reliability in brain areas regarded as part of the cortical pain network. Areas with the highest intersession reliability based on the ICC analysis included the anterior midcingulate cortex, anterior insula, and second somatosensory cortex. Areas with the lowest intersession reliability based on the ICC analysis also showed low spatial reliability; these regions included pregenual anterior cingulate cortex, primary somatosensory cortex, and posterior insula. Thus, this study found regional differences in pain-related BOLD fMRI response reliability, which may provide useful information to guide longitudinal pain studies. A simple motor task (finger-thumb opposition) was performed by the same subjects in the same sessions as the painful heat stimuli were delivered. Intersession reliability of fMRI activation in cortical motor areas was comparable to previously published findings for both spatial overlap and ICC measures, providing support for the validity of the analytical approach used to assess intersession reliability of pain-related fMRI activation. A secondary finding of this study is that the use of standard ICC alone as a measure of reliability may not be sufficient, as the underlying variance structure of an fMRI dataset can result in inappropriately high ICC values; a method to eliminate these false positive results was used in this study and is recommended for future studies of test–retest reliability. PMID:25161897

  9. A Note on Structural Equation Modeling Estimates of Reliability

    ERIC Educational Resources Information Center

    Yang, Yanyun; Green, Samuel B.

    2010-01-01

    Reliability can be estimated using structural equation modeling (SEM). Two potential problems with this approach are that estimates may be unstable with small sample sizes and biased with misspecified models. A Monte Carlo study was conducted to investigate the quality of SEM estimates of reliability by themselves and relative to coefficient…

  10. The development of form two mathematics i-Think module (Mi-T2)

    NASA Astrophysics Data System (ADS)

    Yao, Foo Jing; Abdullah, Mohd Faizal Nizam Lee; Tien, Lee Tien

    2017-05-01

    This study aims to develop a training module i-THINK Mathematics Form Two (Mi-T2) to increase the higher-order thinking skills of students. The Mi-T2 training module was built based on the Sidek Module Development Model (2001). Constructivist learning theory, cognitive learning theory, i-THINK map and higher order thinking skills were the building blocks of the module development. In this study, researcher determined the validity and reliability of Mi-T2 module. The design being used in this study was descriptive study. To determine the needs of Mi-T2 module, questionnaires and literature review were used to collect data. When the need of the module was determined, the module was built and a pilot study was conducted to test the reliability of the Mi-T2 module. The pilot study was conducted at a secondary school in North Kinta, Perak. A Form Two class was selected to be the sample study through clustered random sampling. The pilot study was conducted for two months and one topic had been studied. The Mi-T2 module was evaluated by five expert panels to determine the content validity of the module. The instruments being used in the study were questionnaires about the necessity of the Mi-T2 module for guidance, questionnaires about the validity of the module and questionnaires concerning the reliability of the module. Statistical analysis was conducted to determine the validity and reliability coefficients of the Mi-T2 module. The content validity of Mi-T2 module was determined by Cohen's Kappa's (1968) agreement coefficient and the reliability of Mi-T2 module was determined by Cronbach Alpha's value scale. The content validity of Mi-T2 module was 0.89 and the Cronbach Alpha's value of Mi-T2 module was 0.911.

  11. Examination of Anomalous World Experience: A Report on Reliability.

    PubMed

    Conerty, Joseph; Skodlar, Borut; Pienkos, Elizabeth; Zadravek, Tina; Byrom, Greg; Sass, Louis

    2017-01-01

    The EAWE (Examination of Anomalous World Experience) is a newly developed, semi-structured interview that aims to capture anomalies of subjectivity, common in schizophrenia spectrum disorders, that pertain to experiences of the lived world, including space, time, people, language, atmosphere, and certain existential attitudes. By contrast, previous empirical studies of subjective experience in schizophrenia have focused largely on disturbances in self-experience. To assess the reliability of the EAWE, including internal consistency and interrater reliability. In the course of developing the EAWE, two distinct studies were conducted, one in the United States and the other in Slovenia. Thirteen patients diagnosed with schizophrenia spectrum or mood disorders were recruited for the US study. Fifteen such patients were recruited for the Slovenian study. Two live interviewers conducted the EAWE in the US. The Slovenian interviews were completed by one live interviewer with a second rater reviewing audiorecordings of the interview. Internal consistency and interrater reliability were calculated independently for each study, utilizing Cronbach's α, Spearman's ρ, and Cohen's κ. Each study yielded high internal consistency (Cronbach's α >0.82) and high interrater reliability for total EAWE scores (ρ > 0.83; average κ values were at least 0.78 for each study, with EAWE domain-specific κ not lower than 0.73). The EAWE, containing world-oriented inquiries into anomalies in subjective experience, has adequate reliability for use in a clinical or research setting. © 2017 S. Karger AG, Basel.

  12. Test of Creative Imagination: Validity and Reliability Study

    ERIC Educational Resources Information Center

    Gundogan, Aysun; Ari, Meziyet; Gonen, Mubeccel

    2013-01-01

    The purpose of this study was to investigate validity and reliability of the test of creative imagination. This study was conducted with the participation of 1000 children, aged between 9-14 and were studying in six primary schools in the city center of Denizli Province, chosen by cluster ratio sampling. In the study, it was revealed that the…

  13. Reliable Digit Span: A Systematic Review and Cross-Validation Study

    ERIC Educational Resources Information Center

    Schroeder, Ryan W.; Twumasi-Ankrah, Philip; Baade, Lyle E.; Marshall, Paul S.

    2012-01-01

    Reliable Digit Span (RDS) is a heavily researched symptom validity test with a recent literature review yielding more than 20 studies ranging in dates from 1994 to 2011. Unfortunately, limitations within some of the research minimize clinical generalizability. This systematic review and cross-validation study was conducted to address these…

  14. Turkish Adaptation of the Mentorship Effectiveness Scale: A Validity and Reliability Study

    ERIC Educational Resources Information Center

    Yirci, Ramazan; Karakose, Turgut; Uygun, Harun; Ozdemir, Tuncay Yavuz

    2016-01-01

    The purpose of this study is to adapt the Mentoring Relationship Effectiveness Scale to Turkish, and to conduct validity and reliability tests regarding the scale. The study group consisted of 156 university science students receiving graduate education. Construct validity and factor structure of the scale was analyzed first through exploratory…

  15. The Attitude Determination Scale for Value Acquisition: A Validity and Reliability Study

    ERIC Educational Resources Information Center

    Cetin, Saban

    2017-01-01

    This study aims to develop a measurement tool having measurement reliability with the aim of determining attitudes for values acquisition of secondary school students. The study was conducted on totally 325 high school senior students as 200 female and 125 male students in spring semester of 2014-2015 educational year. In the study, expert opinion…

  16. Objectifying Content Validity: Conducting a Content Validity Study in Social Work Research.

    ERIC Educational Resources Information Center

    Rubio, Doris McGartland; Berg-Weger, Marla; Tebb, Susan S.; Lee, E. Suzanne; Rauch, Shannon

    2003-01-01

    The purpose of this article is to demonstrate how to conduct a content validity study. Instructions on how to calculate a content validity index, factorial validity index, and an interrater reliability index and guide for interpreting these indices are included. Implications regarding the value of conducting a content validity study for…

  17. Qualification Users' Perceptions and Experiences of Assessment Reliability

    ERIC Educational Resources Information Center

    Chamberlain, Suzanne

    2013-01-01

    This paper presents the findings of a study designed to explore qualification users' perceptions and experiences of reliability in the context of national assessment outcomes in England. The study consisted of 17 focus groups conducted across six sectors of qualification users: students, teachers, trainee teachers, job-seekers, employers and…

  18. Reliability of a rating procedure to monitor industry self-regulation codes governing alcohol advertising content.

    PubMed

    Babor, Thomas F; Xuan, Ziming; Proctor, Dwayne

    2008-03-01

    The purposes of this study were to develop reliable procedures to monitor the content of alcohol advertisements broadcast on television and in other media, and to detect violations of the content guidelines of the alcohol industry's self-regulation codes. A set of rating-scale items was developed to measure the content guidelines of the 1997 version of the U.S. Beer Institute Code. Six focus groups were conducted with 60 college students to evaluate the face validity of the items and the feasibility of the procedure. A test-retest reliability study was then conducted with 74 participants, who rated five alcohol advertisements on two occasions separated by 1 week. Average correlations across all advertisements using three reliability statistics (r, rho, and kappa) were almost all statistically significant and the kappas were good for most items, which indicated high test-retest agreement. We also found high interrater reliabilities (intraclass correlations) among raters for item-level and guideline-level violations, indicating that regardless of the specific item, raters were consistent in their general evaluations of the advertisements. Naïve (untrained) raters can provide consistent (reliable) ratings of the main content guidelines proposed in the U.S. Beer Institute Code. The rating procedure may have future applications for monitoring compliance with industry self-regulation codes and for conducting research on the ways in which alcohol advertisements are perceived by young adults and other vulnerable populations.

  19. The Reliability of Evidence Contained in the National Qualifications Framework Impact Study: A Critical Reflection--Research Article

    ERIC Educational Resources Information Center

    Higgs, Philip; Keevy, James

    2007-01-01

    This article reflects on the reliability of the evidence contained in the National Qualifications Framework Impact Study, a longitudinal comparative study conducted by the South African Qualifications Authority since 2002. In so doing, the veracity of evidence-based research in determining the impact of the South African Qualifications Framework…

  20. Reliability and Prevalence of an Atypical Development of Phonological Skills in French-Speaking Dyslexics

    ERIC Educational Resources Information Center

    Sprenger-Charolles, Liliane; Cole, Pascale; Kipffer-Piquard, Agnes; Pinton, Florence; Billard, Catherine

    2009-01-01

    In the present study, conducted with French-speaking children, we examined the reliability (group study) and the prevalence (multiple-case study) of dyslexics' phonological deficits in reading and reading-related skills in comparison with Reading Level (RL) controls. All dyslexics with no comorbidity problem schooled in a special institution for…

  1. Development and Validation of a Coping with Discrimination Scale: Factor Structure, Reliability, and Validity

    ERIC Educational Resources Information Center

    Wei, Meifen; Alvarez, Alvin N.; Ku, Tsun-Yao; Russell, Daniel W.; Bonett, Douglas G.

    2010-01-01

    Four studies were conducted to develop and validate the Coping With Discrimination Scale (CDS). In Study 1, an exploratory factor analysis (N = 328) identified 5 factors: Education/Advocacy, Internalization, Drug and Alcohol Use, Resistance, and Detachment, with internal consistency reliability estimates ranging from 0.72 to 0.90. In Study 2, a…

  2. Astronomy Teaching Self-Efficacy Belief Scale: The Validity and Reliability Study

    ERIC Educational Resources Information Center

    Demirci, Filiz; Ozyurek, Cengiz

    2018-01-01

    The purpose of this study is to develop a reliable and safe scale for determining the self-efficacy levels of science teachers in the teaching of astronomy subjects. The study used a survey approach, which is a qualitative research method. The study was conducted with a total of 106 science teachers working in the secondary schools of Ordu city…

  3. Developing the Irrational Beliefs in Mathematics Scale (IBIMS): A Validity and Reliability Study

    ERIC Educational Resources Information Center

    Kaya, Deniz

    2017-01-01

    The purpose of this study is developing a valid and reliable scale intended to determine the irrational beliefs of students in mathematics. The study was conducted with a study group consisting of 700 students in 2015-2016 academic year. Expert opinions were received for the content and face validity of the scale, and the Exploratory Factor…

  4. Effects of active warning reliability on motorist compliance at highway-railroad grade crossings.

    DOT National Transportation Integrated Search

    2007-11-01

    The Federal Railroad Administration is interested in understanding the effect of warning reliability on motorist compliance to warnings at active grade crossings. The John A. Volpe National Transportation Systems Center conducted two studies to exami...

  5. Eating Disorder Diagnostic Scale: Additional Evidence of Reliability and Validity

    ERIC Educational Resources Information Center

    Stice, Eric; Fisher, Melissa; Martinez, Erin

    2004-01-01

    The authors conducted 4 studies investigating the reliability and validity of the Eating Disorder Diagnostic Scale (HDDS; E. Stice, C. F. Telch, & S. L. Rizvi, 2000), a brief self-report measure for diagnosing anorexia nervosa, bulimia nervosa, and binge eating disorder. Study 1 found that the HDDS showed criterion validity with interview-based…

  6. Reliability of Computerized Neurocognitive Tests for Concussion Assessment: A Meta-Analysis.

    PubMed

    Farnsworth, James L; Dargo, Lucas; Ragan, Brian G; Kang, Minsoo

    2017-09-01

      Although widely used, computerized neurocognitive tests (CNTs) have been criticized because of low reliability and poor sensitivity. A systematic review was published summarizing the reliability of Immediate Post-Concussion Assessment and Cognitive Testing (ImPACT) scores; however, this was limited to a single CNT. Expansion of the previous review to include additional CNTs and a meta-analysis is needed. Therefore, our purpose was to analyze reliability data for CNTs using meta-analysis and examine moderating factors that may influence reliability.   A systematic literature search (key terms: reliability, computerized neurocognitive test, concussion) of electronic databases (MEDLINE, PubMed, Google Scholar, and SPORTDiscus) was conducted to identify relevant studies.   Studies were included if they met all of the following criteria: used a test-retest design, involved at least 1 CNT, provided sufficient statistical data to allow for effect-size calculation, and were published in English.   Two independent reviewers investigated each article to assess inclusion criteria. Eighteen studies involving 2674 participants were retained. Intraclass correlation coefficients were extracted to calculate effect sizes and determine overall reliability. The Fisher Z transformation adjusted for sampling error associated with averaging correlations. Moderator analyses were conducted to evaluate the effects of the length of the test-retest interval, intraclass correlation coefficient model selection, participant demographics, and study design on reliability. Heterogeneity was evaluated using the Cochran Q statistic.   The proportion of acceptable outcomes was greatest for the Axon Sports CogState Test (75%) and lowest for the ImPACT (25%). Moderator analyses indicated that the type of intraclass correlation coefficient model used significantly influenced effect-size estimates, accounting for 17% of the variation in reliability.   The Axon Sports CogState Test, which has a higher proportion of acceptable outcomes and shorter test duration relative to other CNTs, may be a reliable option; however, future studies are needed to compare the diagnostic accuracy of these instruments.

  7. Test-retest reliability of auditory brainstem responses to chirp stimuli in newborns.

    PubMed

    Cobb, Kensi M; Stuart, Andrew

    2014-11-01

    The purpose of this study was to examine the test-retest reliability of auditory brainstem responses (ABRs) to air- and bone-conducted chirp stimuli in newborns as a function of intensity. A repeated measures quasi-experimental design was employed. Thirty healthy newborns participated. ABRs were evoked using 60, 45, and 30 dB nHL air-conducted CE-Chirps and 45, 30, and 15 dB nHL bone-conducted CE-Chirps at a rate of 57.7/s. Measures were repeated by a second tester. Statistically significant correlations (p <.0001) and predictive linear relations (p <.0001) were found between testers for wave V latencies and amplitudes to air- and bone-conducted CE-Chirps. There were also no statistically significant differences between testers with wave V latencies and amplitudes to air- and bone-conducted CE-Chirps (p >.05). As expected, significant differences in wave V latencies and amplitudes were seen as a function of stimulus intensity for air- and bone-conducted CE-Chirps (p <.0001). These results suggest that ABRs to air- and bone-conducted CE-Chirps can be reliably repeated in newborns with different testers. The CE-Chirp may be valuable for both screening and diagnostic audiologic assessments of newborns.

  8. Examining the value of travel time reliability for freight transportation to support freight planning and decision-making.

    DOT National Transportation Integrated Search

    2016-12-01

    This report presents the findings of a valuation study recently conducted in Florida to quantify the : freight users willingness to pay (WTP) for the improvement of transportation-related attributes, : particularly reliability. A stated preference...

  9. ASDE-2 Reliability Improvement Study : Volume I. Operational Data and Modification Recommendations.

    DOT National Transportation Integrated Search

    1974-11-01

    Eight airport sites and the FAA Oklahoma Depot were visited and surveys conducted to obtain reliability, maintainability and performance data on the ASDE-2 Radar System. The data was analyzed and recommendations for modification to the equipment made...

  10. ASDE-2 Reliability Improvement Study : Volume II. Modulator, Receiver and Indicator Interface Recommendations

    DOT National Transportation Integrated Search

    1974-11-01

    Eight airport sites and the FAA Oklahoma Depot were visited and surveys conducted to obtain reliability, maintainability and performance data on the ASDE-2 Radar System. The data was analyzed and recommendations for modification to the equipment made...

  11. Peer Bullying among High School Students: Turkish Version of Bullying Scale

    ERIC Educational Resources Information Center

    Arslan, Nihan

    2017-01-01

    The aim of study was to conduct the reliability and validity studies of the Turkish version of The Forms of Bullying Scale (FBS; Shaw at el., 2013). The Turkish form of the scale was applied on 357 high school students. Scale was examined by the reliability analysis and confirmatory factor analysis within the scope of the adaptation study.…

  12. Development of Social Media Addiction Test (SMAT17)

    ERIC Educational Resources Information Center

    Esgi, Necmi

    2016-01-01

    The aim of this study was to develop a test for assessing individuals' social media addiction; and conducting a reliability and validity study of this scale. Sample for this study was composed of 285 college students between the ages of 18 and 25. Reliability coefficients Cronbach's alpha value was 0.94 and Spearman Brown value was 0.91 for our…

  13. Anomaly Trends for Missions to Mars: Mars Global Surveyor and Mars Odyssey

    NASA Technical Reports Server (NTRS)

    Green, Nelson W.; Hoffman, Alan R.

    2008-01-01

    Conducted as a part of NASA Ultra-Reliability effort: Goal is to design for increased reliability in all NASA missions. Desire is to increase reliability by a factor of 10. Study provides a baseline for current technology. Analyzed anomalies for spacecraft orbiting Mars. Long lived spacecraft. Comparison with current rover missions and past orbiters. Looked for trends to assist design of future missions.

  14. [Turkish validity and reliability study of fear of pain questionnaire-III].

    PubMed

    Ünver, Seher; Turan, Fatma Nesrin

    2018-01-01

    This study aimed to develop a Turkish version of the Fear of Pain Questionnaire-III developed by McNeil and Rainwater (1998) and examine its validity and reliability indicators. The study was conducted with 459 university students studying in the nursing department. The Turkish translation of the scale was conducted by language experts and the original scale owner. Expert opinions were taken for language validity, and the Lawshe's content validity ratio formula was used to calculate the content validity. Exploratory factor analysis was used to assess the construct validity. The factors were rotated using the Varimax rotation (orthogonal) method. For reliability indicators of the questionnaire, the internal consistency coefficient and test re-test reliability were utilized. Explanatory factor analyses using the three-factor model (explaining 50.5% of the total variance) revealed that the item factor loads varied were above the limit value of 0.30 which indicated that the questionnaire had good construct validity. The Cronbach's alpha value for the total questionnaire was 0.938, and test re-test value was 0.846 for the total scale. The Turkish version of the Fear of Pain Questionnaire-III had sufficiently high reliability and validity to be used as a tool in evaluating the fear of pain among the young Turkish population.

  15. An Application-Based Discussion of Construct Validity and Internal Consistency Reliability.

    ERIC Educational Resources Information Center

    Taylor, Dianne L.; Campbell, Kathleen T.

    Several techniques for conducting studies of measurement integrity are explained and illustrated using a heuristic data set from a study of teachers' participation in decision making (D. L. Taylor, 1991). The sample consisted of 637 teachers. It is emphasized that validity and reliability are characteristics of data, and do not inure to tests as…

  16. Value-Eroding Teacher Behaviors Scale: A Validity and Reliability Study

    ERIC Educational Resources Information Center

    Arseven, Zeynep; Kiliç, Abdurrahman; Sahin, Seyma

    2016-01-01

    In the present study, it is aimed to develop a valid and reliable scale for determining value-eroding behaviors of teachers, hence their values of judgment. The items of the "Value-eroding Teacher Behaviors Scale" were designed in the form of 5-point likert type rating scale. The exploratory factor analysis (EFA) was conducted to…

  17. Welding of silver nanowire networks via flash white light and UV-C irradiation for highly conductive and reliable transparent electrodes

    NASA Astrophysics Data System (ADS)

    Chung, Wan-Ho; Kim, Sang-Ho; Kim, Hak-Sung

    2016-08-01

    In this work, silver nanowire inks with hydroxypropyl methylcellulose (HPMC) binders were coated on polyethylene terephthalate (PET) substrates and welded via flash white light and ultraviolet C (UV-C) irradiation to produce highly conductive transparent electrodes. The coated silver nanowire films were firmly welded and embedded into PET substrate successfully at room temperature and under ambient conditions using an in-house flash white light welding system and UV-C irradiation. The effects of light irradiation conditions (light energy, irradiation time, pulse duration, and pulse number) on the silver nanowire networks were studied and optimized. Bending fatigue tests were also conducted to characterize the reliability of the welded transparent conductive silver nanowire films. The surfaces of the welded silver nanowire films were analyzed via scanning electron microscopy (SEM), while the transmittance of the structures was measured using a spectrophotometer. From the results, a highly conductive and transparent silver nanowire film with excellent reliability could be achieved at room temperature under ambient conditions via the combined flash white light and UV-C irradiation welding process.

  18. Welding of silver nanowire networks via flash white light and UV-C irradiation for highly conductive and reliable transparent electrodes

    PubMed Central

    Chung, Wan-Ho; Kim, Sang-Ho; Kim, Hak-Sung

    2016-01-01

    In this work, silver nanowire inks with hydroxypropyl methylcellulose (HPMC) binders were coated on polyethylene terephthalate (PET) substrates and welded via flash white light and ultraviolet C (UV-C) irradiation to produce highly conductive transparent electrodes. The coated silver nanowire films were firmly welded and embedded into PET substrate successfully at room temperature and under ambient conditions using an in-house flash white light welding system and UV-C irradiation. The effects of light irradiation conditions (light energy, irradiation time, pulse duration, and pulse number) on the silver nanowire networks were studied and optimized. Bending fatigue tests were also conducted to characterize the reliability of the welded transparent conductive silver nanowire films. The surfaces of the welded silver nanowire films were analyzed via scanning electron microscopy (SEM), while the transmittance of the structures was measured using a spectrophotometer. From the results, a highly conductive and transparent silver nanowire film with excellent reliability could be achieved at room temperature under ambient conditions via the combined flash white light and UV-C irradiation welding process. PMID:27553755

  19. Assessing reliability and validity measures in managed care studies.

    PubMed

    Montoya, Isaac D

    2003-01-01

    To review the reliability and validity literature and develop an understanding of these concepts as applied to managed care studies. Reliability is a test of how well an instrument measures the same input at varying times and under varying conditions. Validity is a test of how accurately an instrument measures what one believes is being measured. A review of reliability and validity instructional material was conducted. Studies of managed care practices and programs abound. However, many of these studies utilize measurement instruments that were developed for other purposes or for a population other than the one being sampled. In other cases, instruments have been developed without any testing of the instrument's performance. The lack of reliability and validity information may limit the value of these studies. This is particularly true when data are collected for one purpose and used for another. The usefulness of certain studies without reliability and validity measures is questionable, especially in cases where the literature contradicts itself

  20. Reliability of a Malay-translated questionnaire for use in a hand-arm vibration syndrome study in Malaysia.

    PubMed

    Su, T A; Hoe, V C W

    2008-12-01

    Validity and reliability of the information relating to hand-transmitted vibration exposure and vibration-related health outcome are very important for case finding in hand-arm vibration syndrome (HAVS) studies. In a local HAVS study among a group of construction workers in Kuala Lumpur, Malaysia, a questionnaire translated into Malay was created based on the Hand-transmitted Vibration Health Surveillance--Initial Questionnaire and Clinical Assessment, from Vibration Injury Network. This study was conducted to determine the reliability of standardised questions in the questionnaire used in the study. 15 subjects were selected randomly from the sampling frame of the HAVS study. Test-retest reliability was conducted on all items contained in parts 1-6 of the questionnaire and clinical assessment form, with an interval of 13-14 days between the first and second administration. Kappa coefficient and percentage agreement were calculated for all standardised questions. The kappa coefficient and percentage agreement for all standardised questions varied from -0.174 to 1.000 and 66.7 to 100.0 percent, respectively. The kappa coefficient for important questions related to current vibratory tool usage, tingling, numbness and hand grip weakness were 0.714, 0.432, -0.077 and -0.120, respectively, while the percentage agreement for current vibratory tool usage, finger colour change, tingling, numbness and hand grip weakness were 85.7 percent, 92.8 percent, 79.5 percent, 85.7 percent and 71.4 percent, respectively. Intra-rater reliability on the extent of vibration exposure was good, with the intra-class correlation coefficient (95 percent confidence interval) ranging from 0.786 (0.334-0.931) to 0.975 (0.923-0.992). Critical questions on vascular, neurological and musculoskeletal symptoms of HAVS were found to be reliable. The history on the extent of vibration exposure revealed good reliability when explored by the investigator alone. This questionnaire is considered reliable to be used in the study of HAVS among construction workers working in a construction site.

  1. A Monte Carlo Simulation Study of the Reliability of Intraindividual Variability

    PubMed Central

    Estabrook, Ryne; Grimm, Kevin J.; Bowles, Ryan P.

    2012-01-01

    Recent research has seen intraindividual variability (IIV) become a useful technique to incorporate trial-to-trial variability into many types of psychological studies. IIV as measured by individual standard deviations (ISDs) has shown unique prediction to several types of positive and negative outcomes (Ram, Rabbit, Stollery, & Nesselroade, 2005). One unanswered question regarding measuring intraindividual variability is its reliability and the conditions under which optimal reliability is achieved. Monte Carlo simulation studies were conducted to determine the reliability of the ISD compared to the intraindividual mean. The results indicate that ISDs generally have poor reliability and are sensitive to insufficient measurement occasions, poor test reliability, and unfavorable amounts and distributions of variability in the population. Secondary analysis of psychological data shows that use of individual standard deviations in unfavorable conditions leads to a marked reduction in statistical power, although careful adherence to underlying statistical assumptions allows their use as a basic research tool. PMID:22268793

  2. Reliability of excess-flow check-valves in turbine lubrication systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dundas, R.E.

    1996-12-31

    Reliability studies on excess-flow check valves installed in a gas turbine lubrication system for prevention of spray fires subsequent to fracture or separation of lube lines were conducted. Fault-tree analyses are presented for the case of failure of a valve to close when called upon by separation of a downstream line, as well as for the case of accidental closure during normal operation, leading to interruption of lubricating oil flow to a bearing. The probabilities of either of these occurrences are evaluated. The results of a statistical analysis of accidental closure of excess-flow check valves in commercial airplanes in themore » period 1986--91 are also given, as well as a summary of reliability studies on the use of these valves in residential gas installations, conducted under the sponsorship of the Gas Research Institute.« less

  3. Development of an instrument to measure the use of behaviors taught in the American Physical Therapy Association Clinical Instructor Education and Credentialing Program (APTA CIECP): a pilot study.

    PubMed

    Bridges, Patricia H; Carter, Vincent; Rehm, Stephanie; Tintl, Sara Bowers; Halperin, Rebecca; Kniesly, Elizabeth; Pelino, Soni

    2013-01-01

    Conduct a pilot study to establish the reliability and validity of a survey instrument that directly measures the objectives and content of the APTA CIECP; and measure the self-reported frequency of use of the behaviors taught in the APTA CIECP. Eighteen (18) APTA credentialed CIs. Develop a web-based survey consisting of 58 items representative of the behaviors taught in the APTA CIECP and 8 demographic characteristics. Establish the content validity and reliability of the survey instrument. Conduct a descriptive analysis of the frequency of self-reported use of the behaviors. The APTA Clinical Instructor Education Board (CIEB) reviewed the items and determined that the items matched the objectives and content of the APTA CIECP, thereby establishing content validity. Cronbach's alpha coefficients ranging from 0.79-0.90 confirmed the reliability. The overall mean for all items on a 1-6 scale was 4.81. The content validity and reliability of the survey instrument were established. The outcomes of this pilot study suggest that when measured by a valid and reliable instrument that is representative of the objectives and content of the CIECP, the behaviors taught in the CIECP are being applied in the clinical setting by APTA credentialed clinical instructors.

  4. Space Tug Point Design Study. Volume 3: Design Definition. Part 2: Insulation, Meteoroid Protection, Structures, Mass Properties, GSE, Reliability and Safety

    NASA Technical Reports Server (NTRS)

    1973-01-01

    A study was conducted to determine the configuration and performance of a space tug. Detailed descriptions of the insulation, meteoroid protection, primary structure, and ground support equipment are presented. Technical assessments leading to the concept selection are analyzed. The tug mass properties, reliability, and safety assessments are included.

  5. Adaptation of General Belongingness Scale into Turkish for Adolescents: Validity and Reliability Studies

    ERIC Educational Resources Information Center

    Yildiz, Mehmet Ali

    2017-01-01

    The current research aims to adapt the General Belongingness Scale (GBS), developed by Malone, Pillow, and Osman (2012), into Turkish for adolescents and to conduct the validity and reliability studies for it. Ages of the participants, a total of 567 adolescents including 274 males (48.3%) and 293 females (51.7%) ranged between 14 and 18 (average…

  6. Reliability and Validity of Curriculum-Based Informal Reading Inventories.

    ERIC Educational Resources Information Center

    Fuchs, Lynn; And Others

    A study was conducted to explore the reliability and validity of three prominent procedures used in informal reading inventories (IRIs): (1) choosing a 95% word recognition accuracy standard for determining student instructional level, (2) arbitrarily selecting a passage to represent the difficulty level of a basal reader, and (3) employing…

  7. Discrete component bonding and thick film materials study. [of capacitor chips bonded with solders and conductive epoxies

    NASA Technical Reports Server (NTRS)

    Kinser, D. L.

    1976-01-01

    The bonding reliability of discrete capacitor chips bonded with solders and conductive epoxies was examined along with the thick film resistor materials consisting of iron oxide phosphate and vanadium oxide phosphates. It was concluded from the bonding reliability studies that none of the wide range of types of solders examined is capable of resisting failure during thermal cycling while the conductive epoxy gives substantially lower failure rates. The thick film resistor studies proved the feasibility of iron oxide phosphate resistor systems although some environmental sensitivity problems remain. One of these resistor compositions has inadvertently proven to be a candidate for thermistor applications because of the excellent control achieved upon the temperature coefficient of resistance. One new and potentially damaging phenomenon observed was the degradation of thick film conductors during the course of thermal cycling.

  8. Validity and reliability of a Swedish questionnaire for assessing satisfaction with housing and housing support for persons with psychiatric disabilities.

    PubMed

    Brolin, Rosita; Rask, Mikael; Syrén, Susanne; Brunt, David Arthur

    2013-10-01

    The aim of this study was to investigate the reliability and validity of a questionnaire for studying satisfaction with housing and housing support for people with psychiatric disabilities. Most items were gathered from English language questionnaires. These were translated and adapted to a Swedish context and items concerning housing support were added. Two studies were conducted. The first, a test-retest reliability analysis, was performed in a pilot study with 53 participants; in the second study, which had 370 participants, a five factor solution with good internal consistency emerged. Further development of the questionnaire is discussed.

  9. Reliability and Validity of the Sensory Component of the International Standards for Neurological Classification of Spinal Cord Injury (ISNCSCI): A Systematic Review.

    PubMed

    Hales, M; Biros, E; Reznik, J E

    2015-01-01

    Since 1982, the International Standards for Neurological Classification of Spinal Cord Injury (ISNCSCI) has been used to classify sensation of spinal cord injury (SCI) through pinprick and light touch scores. The absence of proprioception, pain, and temperature within this scale creates questions about its validity and accuracy. To assess whether the sensory component of the ISNCSCI represents a reliable and valid measure of classification of SCI. A systematic review of studies examining the reliability and validity of the sensory component of the ISNCSCI published between 1982 and February 2013 was conducted. The electronic databases MEDLINE via Ovid, CINAHL, PEDro, and Scopus were searched for relevant articles. A secondary search of reference lists was also completed. Chosen articles were assessed according to the Oxford Centre for Evidence-Based Medicine hierarchy of evidence and critically appraised using the McMasters Critical Review Form. A statistical analysis was conducted to investigate the variability of the results given by reliability studies. Twelve studies were identified: 9 reviewed reliability and 3 reviewed validity. All studies demonstrated low levels of evidence and moderate critical appraisal scores. The majority of the articles (~67%; 6/9) assessing the reliability suggested that training was positively associated with better posttest results. The results of the 3 studies that assessed the validity of the ISNCSCI scale were confounding. Due to the low to moderate quality of the current literature, the sensory component of the ISNCSCI requires further revision and investigation if it is to be a useful tool in clinical trials.

  10. Reliability and Validity of the Sensory Component of the International Standards for Neurological Classification of Spinal Cord Injury (ISNCSCI): A Systematic Review

    PubMed Central

    Hales, M.; Biros, E.

    2015-01-01

    Background: Since 1982, the International Standards for Neurological Classification of Spinal Cord Injury (ISNCSCI) has been used to classify sensation of spinal cord injury (SCI) through pinprick and light touch scores. The absence of proprioception, pain, and temperature within this scale creates questions about its validity and accuracy. Objectives: To assess whether the sensory component of the ISNCSCI represents a reliable and valid measure of classification of SCI. Methods: A systematic review of studies examining the reliability and validity of the sensory component of the ISNCSCI published between 1982 and February 2013 was conducted. The electronic databases MEDLINE via Ovid, CINAHL, PEDro, and Scopus were searched for relevant articles. A secondary search of reference lists was also completed. Chosen articles were assessed according to the Oxford Centre for Evidence-Based Medicine hierarchy of evidence and critically appraised using the McMasters Critical Review Form. A statistical analysis was conducted to investigate the variability of the results given by reliability studies. Results: Twelve studies were identified: 9 reviewed reliability and 3 reviewed validity. All studies demonstrated low levels of evidence and moderate critical appraisal scores. The majority of the articles (~67%; 6/9) assessing the reliability suggested that training was positively associated with better posttest results. The results of the 3 studies that assessed the validity of the ISNCSCI scale were confounding. Conclusions: Due to the low to moderate quality of the current literature, the sensory component of the ISNCSCI requires further revision and investigation if it is to be a useful tool in clinical trials. PMID:26363591

  11. The Multitheoretical List of Therapeutic Interventions - 30 items (MULTI-30).

    PubMed

    Solomonov, Nili; McCarthy, Kevin S; Gorman, Bernard S; Barber, Jacques P

    2018-01-16

    To develop a brief version of the Multitheoretical List of Therapeutic Interventions (MULTI-60) in order to decrease completion time burden by approximately half, while maintaining content coverage. Study 1 aimed to select 30 items. Study 2 aimed to examine the reliability and internal consistency of the MULTI-30. Study 3 aimed to validate the MULTI-30 and ensure content coverage. In Study 1, the sample included 186 therapist and 255 patient MULTI ratings, and 164 ratings of sessions coded by trained observers. Internal consistency (Chronbach's alpha and McDonald's omega) was calculated and confirmatory factor analysis was conducted. Psychotherapy experts rated content relevance. Study 2 included a sample of 644 patient and 522 therapist ratings, and 793 codings of psychotherapy sessions. In Study 3, the sample included 33 codings of sessions. A series of regression analyses was conducted to examine replication of previously published findings using the MULTI-30. The MULTI-30 was found valid, reliable, and internally consistent across 2564 ratings examined across the three studies presented. The MULTI-30 a brief and reliable process measure. Future studies are required for further validation.

  12. Workplace assessments and functional capacity evaluations: current beliefs of therapists in Australia.

    PubMed

    Innes, Ev; Straker, Leon

    2003-01-01

    The purpose of this study was to understand the current beliefs of therapists in Australia, and the strategies they use to address the issues of credibility, reliability, consistency, trustworthiness, validity, generalisability and quality in conducting work-related assessments. In-depth semi-structured interviews were conducted with 26 occupational therapists and physiotherapists from around Australia. Participants expressed the belief that the therapist was the assessment instrument and was central to the credibility of an assessment. Conflict was reported when participants modified standardised assessments in an attempt to focus on context relevant activities and tasks. Participants were aware of the issues of reliability and validity but believed it was not practical to establish these aspects formally in most work-related assessments. The strategies used to achieve credibility, reliability, consistency, trustworthiness, validity, generalisability and quality were similar to those recommended for use in qualitative research. The strategies identified in this study can provide the basis for therapists to examine how they conduct work-related assessments and consider whether they currently use these strategies or have the opportunity to implement others.

  13. Integrating Reliability Analysis with a Performance Tool

    NASA Technical Reports Server (NTRS)

    Nicol, David M.; Palumbo, Daniel L.; Ulrey, Michael

    1995-01-01

    A large number of commercial simulation tools support performance oriented studies of complex computer and communication systems. Reliability of these systems, when desired, must be obtained by remodeling the system in a different tool. This has obvious drawbacks: (1) substantial extra effort is required to create the reliability model; (2) through modeling error the reliability model may not reflect precisely the same system as the performance model; (3) as the performance model evolves one must continuously reevaluate the validity of assumptions made in that model. In this paper we describe an approach, and a tool that implements this approach, for integrating a reliability analysis engine into a production quality simulation based performance modeling tool, and for modeling within such an integrated tool. The integrated tool allows one to use the same modeling formalisms to conduct both performance and reliability studies. We describe how the reliability analysis engine is integrated into the performance tool, describe the extensions made to the performance tool to support the reliability analysis, and consider the tool's performance.

  14. Environmental Affective Dispositions Scale (EADS): The Study of Validity and Reliability and Adaptation to Turkish

    ERIC Educational Resources Information Center

    Fettahlioglu, Pinar; Timur, Serkan; Timur, Betül

    2016-01-01

    The aim of this study is to conduct a research under circumstances of Turkey about the validity and reliability of the Affective Tendencies towards Environmental Scale prepared by Yavetz, Goldman and Pe'er (2009). The translation of this scale to Turkish was done by the researchers and language specialists. And then, the scale was evaluated by the…

  15. Undergraduate student nurses' attitudes towards using social media websites: A study from Jordan.

    PubMed

    Al-Shdayfat, Noha M

    2018-07-01

    The use of social media by university students is recognized worldwide. Student nurses are no exception, yet no studies have been reported to investigate the nurse students' use and views of social media in Jordan. The current study aims to assess the validity and reliability of an Arabic version of the modified Students Nurses' Use and Views of Social Media survey. In a cross-sectional study conducted on 395 student nurses aged 19-39 enrolled at two universities (one public and one private) in north Jordan, information on their use and attitude to social media was obtained using the Arabic version of the Students Nurses' Use and Views of Social Media survey. Exploratory factor analysis and correlation matrices were conducted to assess the validity and reliability of the tool. The Arabic version of the tool had a 0.84 alpha of internal consistency indicating a high level of reliability. The scale showed multi-dimensionality with items loading on two factors. The Arabic version of the Students Nurses' Use and Views of Social Media questionnaire demonstrated initial reliability and validity. This study reports positive attitudes of Jordanian student nurses towards professional and academic use of social media. Copyright © 2018 Elsevier Ltd. All rights reserved.

  16. Development, validity and reliability of the short multidimensional positive mental health instrument.

    PubMed

    Vaingankar, Janhavi Ajit; Subramaniam, Mythily; Abdin, Edimansyah; Picco, Louisa; Chua, Boon Yiang; Eng, Goi Khia; Sambasivam, Rajeswari; Shafie, Saleha; Zhang, Yunjue; Chong, Siow Ann

    2014-06-01

    The 47-item positive mental health (PMH) instrument measures the level of PMH in multiethnic adult Asian populations. This study aimed to (1) develop a short PMH instrument and (2) establish its validity and reliability among the adult Singapore population. Two separate studies were conducted among adult community-dwelling Singapore residents of Chinese, Malay or Indian ethnicity where participants completed self-administered questionnaires. In the first study, secondary data analysis was conducted using confirmatory factor analysis (CFA) to shorten the PMH instrument. In the second study, the newly developed short PMH instrument and other scales were administered to 201 residents to establish its factor structure, validity and reliability. A 20-item short PMH instrument fulfilling a higher-order six-factor structure was developed following secondary analysis. The mean age of the participants in the second study was 41 years and about 53% were women. One item with poor factor loading was further removed to generate a 19-item version of the PMH instrument. CFA demonstrated a first-order six-factor model of the short PMH instrument. The PMH-19 instrument and its subscales fulfilled criterion validity hypotheses. Internal consistency and test-retest reliability of the PMH-19 instrument were high (Cronbach's α coefficient = 0.87; intraclass correlation coefficient = 0.93, respectively). The 19-item PMH instrument is multidimensional, valid and reliable, and most importantly, with its reduced administration time, the short PMH instrument can be used to measure and evaluate PMH in Asian communities.

  17. Comparative Analysis of the Reliability of Steel Structure with Pinned and Rigid Nodes Subjected to Fire

    NASA Astrophysics Data System (ADS)

    Kubicka, Katarzyna; Radoń, Urszula; Szaniec, Waldemar; Pawlak, Urszula

    2017-10-01

    The paper concerns the reliability analysis of steel structures subjected to high temperatures of fire gases. Two types of spatial structures were analysed, namely with pinned and rigid nodes. The fire analysis was carried out according to prescriptions of Eurocode. The static-strength analysis was conducted using the finite element method (FEM). The MES3D program, developed by Szaniec (Kielce University of Technology, Poland), was used for this purpose. The results received from MES3D made it possible to carry out the reliability analysis using the Numpress Explore program that was developed at the Institute of Fundamental Technological Research of the Polish Academy of Sciences [9]. The measurement of reliability of structures is the Hasofer-Lind reliability index (β). The reliability analysis was carried out according to approximation (FORM, SORM) and simulation (Importance Sampling, Monte Carlo) methods. As the fire progresses, the value of reliability index decreases. The analysis conducted for the study made it possible to evaluate the impact of node types on those changes. In real structures, it is often difficult to define correctly types of nodes, so some simplifications are made. The presented analysis contributes to the recognition of consequences of such assumptions for the safety of structures, subjected to fire.

  18. Developing evaluation scales for horticultural therapy.

    PubMed

    Im, Eun-Ae; Park, Sin-Ae; Son, Ki-Cheol

    2018-04-01

    This study developed evaluation scales for measuring the effects of horticultural therapy in practical settings. Qualitative and quantitative research, including three preliminary studies and a main study, were conducted. In the first study, a total of 779 horticultural therapists answered an open-end questionnaire based on 58 items about elements of occupational therapy and seven factors about singularity of horticultural therapy. In the second study, 20 horticultural therapists participated in in-depth interviews. In the third study, a Delphi method was conducted with 24 horticultural therapists to build a model of assessment indexes and ensure the validity. In the final study, the reserve scales were tested by 121 horticultural therapists in their practical settings for 1045 clients, to verify their reliability and validity. Preliminary questions in the effects area of horticultural therapy were developed in the first study, and validity for the components in the second study. In the third study, an expert Delphi survey was conducted as part of content validity verification of the preliminary tool of horticultural therapy for physical, cognitive, psychological-emotional, and social areas. In the final study, the evaluation tool, which verified the construct, convergence, discriminant, and predictive validity and reliability test, was used to finalise the evaluation tool. The effects of horticultural therapy were classified as four different aspects, namely, physical, cognitive, psycho-emotional, and social, based on previous studies on the effects of horticultural therapy. 98 questions in the four aspects were selected as reserve scales. The reliability of each scale was calculated as 0.982 in physical, 0.980 in cognitive, 0.965 in psycho-emotional, and 0.972 in social aspects based on the Cronbach's test of intra-item internal consistency and half reliability of Spearman-Brown. This study was the first to demonstrate validity and reliability by simultaneously developing four measures of horticultural therapy effectiveness, namely, physical, cognitive, psychological-emotional, and social, both locally and externally. It is especially worthwhile in that it can be applied in common to people. Copyright © 2018 Elsevier Ltd. All rights reserved.

  19. The quality of systematic reviews about interventions for refractive error can be improved: a review of systematic reviews.

    PubMed

    Mayo-Wilson, Evan; Ng, Sueko Matsumura; Chuck, Roy S; Li, Tianjing

    2017-09-05

    Systematic reviews should inform American Academy of Ophthalmology (AAO) Preferred Practice Pattern® (PPP) guidelines. The quality of systematic reviews related to the forthcoming Preferred Practice Pattern® guideline (PPP) Refractive Errors & Refractive Surgery is unknown. We sought to identify reliable systematic reviews to assist the AAO Refractive Errors & Refractive Surgery PPP. Systematic reviews were eligible if they evaluated the effectiveness or safety of interventions included in the 2012 PPP Refractive Errors & Refractive Surgery. To identify potentially eligible systematic reviews, we searched the Cochrane Eyes and Vision United States Satellite database of systematic reviews. Two authors identified eligible reviews and abstracted information about the characteristics and quality of the reviews independently using the Systematic Review Data Repository. We classified systematic reviews as "reliable" when they (1) defined criteria for the selection of studies, (2) conducted comprehensive literature searches for eligible studies, (3) assessed the methodological quality (risk of bias) of the included studies, (4) used appropriate methods for meta-analyses (which we assessed only when meta-analyses were reported), (5) presented conclusions that were supported by the evidence provided in the review. We identified 124 systematic reviews related to refractive error; 39 met our eligibility criteria, of which we classified 11 to be reliable. Systematic reviews classified as unreliable did not define the criteria for selecting studies (5; 13%), did not assess methodological rigor (10; 26%), did not conduct comprehensive searches (17; 44%), or used inappropriate quantitative methods (3; 8%). The 11 reliable reviews were published between 2002 and 2016. They included 0 to 23 studies (median = 9) and analyzed 0 to 4696 participants (median = 666). Seven reliable reviews (64%) assessed surgical interventions. Most systematic reviews of interventions for refractive error are low methodological quality. Following widely accepted guidance, such as Cochrane or Institute of Medicine standards for conducting systematic reviews, would contribute to improved patient care and inform future research.

  20. The Yale-Brown Obsessive Compulsive Scale: A Reliability Generalization Meta-Analysis.

    PubMed

    López-Pina, José Antonio; Sánchez-Meca, Julio; López-López, José Antonio; Marín-Martínez, Fulgencio; Núñez-Núñez, Rosa Maria; Rosa-Alcázar, Ana I; Gómez-Conesa, Antonia; Ferrer-Requena, Josefa

    2015-10-01

    The Yale-Brown Obsessive Compulsive Scale (Y-BOCS) is the most frequently applied test to assess obsessive compulsive symptoms. We conducted a reliability generalization meta-analysis on the Y-BOCS to estimate the average reliability, examine the variability among the reliability estimates, search for moderators, and propose a predictive model that researchers and clinicians can use to estimate the expected reliability of the Y-BOCS. We included studies where the Y-BOCS was applied to a sample of adults and reliability estimate was reported. Out of the 11,490 references located, 144 studies met the selection criteria. For the total scale, the mean reliability was 0.866 for coefficients alpha, 0.848 for test-retest correlations, and 0.922 for intraclass correlations. The moderator analyses led to a predictive model where the standard deviation of the total test and the target population (clinical vs. nonclinical) explained 38.6% of the total variability among coefficients alpha. Finally, clinical implications of the results are discussed. © The Author(s) 2014.

  1. The validation of Huffaz Intelligence Test (HIT)

    NASA Astrophysics Data System (ADS)

    Rahim, Mohd Azrin Mohammad; Ahmad, Tahir; Awang, Siti Rahmah; Safar, Ajmain

    2017-08-01

    In general, a hafiz who can memorize the Quran has many specialties especially in respect to their academic performances. In this study, the theory of multiple intelligences introduced by Howard Gardner is embedded in a developed psychometric instrument, namely Huffaz Intelligence Test (HIT). This paper presents the validation and the reliability of HIT of some tahfiz students in Malaysia Islamic schools. A pilot study was conducted involving 87 huffaz who were randomly selected to answer the items in HIT. The analysis method used includes Partial Least Square (PLS) on reliability, convergence and discriminant validation. The study has validated nine intelligences. The findings also indicated that the composite reliabilities for the nine types of intelligences are greater than 0.8. Thus, the HIT is a valid and reliable instrument to measure the multiple intelligences among huffaz.

  2. The reliability of physical examination tests for the diagnosis of anterior cruciate ligament rupture--A systematic review.

    PubMed

    Lange, Toni; Freiberg, Alice; Dröge, Patrik; Lützner, Jörg; Schmitt, Jochen; Kopkow, Christian

    2015-06-01

    Systematic literature review. Despite their frequent application in routine care, a systematic review on the reliability of clinical examination tests to evaluate the integrity of the ACL is missing. To summarize and evaluate intra- and interrater reliability research on physical examination tests used for the diagnosis of ACL tears. A comprehensive systematic literature search was conducted in MEDLINE, EMBASE and AMED until May 30th 2013. Studies were included if they assessed the intra- and/or interrater reliability of physical examination tests for the integrity of the ACL. Methodological quality was evaluated with the Quality Appraisal of Reliability Studies (QAREL) tool by two independent reviewers. 110 hits were achieved of which seven articles finally met the inclusion criteria. These studies examined the reliability of four physical examination tests. Intrarater reliability was assessed in three studies and ranged from fair to almost perfect (Cohen's k = 0.22-1.00). Interrater reliability was assessed in all included studies and ranged from slight to almost perfect (Cohen's k = 0.02-0.81). The Lachman test is the physical tests with the highest intrarater reliability (Cohen's k = 1.00), the Lachman test performed in prone position the test with the highest interrater reliability (Cohen's k = 0.81). Included studies were partly of low methodological quality. A meta-analysis could not be performed due to the heterogeneity in study populations, reliability measures and methodological quality of included studies. Systematic investigations on the reliability of physical examination tests to assess the integrity of the ACL are scarce and of varying methodological quality. Copyright © 2014 Elsevier Ltd. All rights reserved.

  3. The Effects of Testlets on Reliability and Differential Item Functioning

    ERIC Educational Resources Information Center

    Teker, Gulsen Tasdelen; Dogan, Nuri

    2015-01-01

    Reliability and differential item functioning (DIF) analyses were conducted on testlets displaying local item dependence in this study. The data set employed in the research was obtained from the answers given by 1,500 students to the 20 items included in six testlets given in English Proficiency Exam by the School of Foreign Languages of a state…

  4. The Effect of Observation Length and Presentation Order on the Reliability and Validity of an Observational Measure of Teaching Quality

    ERIC Educational Resources Information Center

    Mashburn, Andrew J.; Meyer, J. Patrick; Allen, Joseph P.; Pianta, Robert C.

    2014-01-01

    Observational methods are increasingly being used in classrooms to evaluate the quality of teaching. Operational procedures for observing teachers are somewhat arbitrary in existing measures and vary across different instruments. To study the effect of different observation procedures on score reliability and validity, we conducted an experimental…

  5. The Development of a Practical and Reliable Assessment Measure for Atopic Dermatitis (ADAM).

    ERIC Educational Resources Information Center

    Charman, Denise; Varigos, George; Horne, David J. de L.; Oberklaid, Frank

    1999-01-01

    A study was conducted in Australia to develop a reliable, valid, and practical measure of atopic dermatitis. The test development process and validity evaluation with two doctors and 51 patients are discussed. Results suggest that operational definitions of the scales need to be defined more clearly. The measure satisfies assumptions for a partial…

  6. Reliability of muscle strength assessment in chronic post-stroke hemiparesis: a systematic review and meta-analysis.

    PubMed

    Rabelo, Michelle; Nunes, Guilherme S; da Costa Amante, Natália Menezes; de Noronha, Marcos; Fachin-Martins, Emerson

    2016-02-01

    Muscle weakness is the main cause of motor impairment among stroke survivors and is associated with reduced peak muscle torque. To systematically investigate and organize the evidence of the reliability of muscle strength evaluation measures in post-stroke survivors with chronic hemiparesis. Two assessors independently searched four electronic databases in January 2014 (Medline, Scielo, CINAHL, Embase). Inclusion criteria comprised studies on reliability on muscle strength assessment in adult post-stroke patients with chronic hemiparesis. We extracted outcomes from included studies about reliability data, measured by intraclass correlation coefficient (ICC) and/or similar. The meta-analyses were conducted only with isokinetic data. Of 450 articles, eight articles were included for this review. After quality analysis, two studies were considered of high quality. Five different joints were analyzed within the included studies (knee, hip, ankle, shoulder, and elbow). Their reliability results varying from low to very high reliability (ICCs from 0.48 to 0.99). Results of meta-analysis for knee extension varying from high to very high reliability (pooled ICCs from 0.89 to 0.97), for knee flexion varying from high to very high reliability (pooled ICCs from 0.84 to 0.91) and for ankle plantar flexion showed high reliability (pooled ICC = 0.85). Objective muscle strength assessment can be reliably used in lower and upper extremities in post-stroke patients with chronic hemiparesis.

  7. An empirical study of flight control software reliability

    NASA Technical Reports Server (NTRS)

    Dunham, J. R.; Pierce, J. L.

    1986-01-01

    The results of a laboratory experiment in flight control software reliability are reported. The experiment tests a small sample of implementations of a pitch axis control law for a PA28 aircraft with over 14 million pitch commands with varying levels of additive input and feedback noise. The testing which uses the method of n-version programming for error detection surfaced four software faults in one implementation of the control law. The small number of detected faults precluded the conduct of the error burst analyses. The pitch axis problem provides data for use in constructing a model in the prediction of the reliability of software in systems with feedback. The study is undertaken to find means to perform reliability evaluations of flight control software.

  8. Inter-clinician and intra-clinician reliability of force application during joint mobilization: a systematic review.

    PubMed

    Gorgos, Kara S; Wasylyk, Nicole T; Van Lunen, Bonnie L; Hoch, Matthew C

    2014-04-01

    Joint mobilizations are commonly used by clinicians to decrease pain and restore joint arthrokinematics following musculoskeletal injury. The force applied during a joint mobilization treatment is subjective to the individual clinician but may have an effect on patient outcomes. The purpose of this systematic review was to critically appraise and synthesize the studies which examined the reliability of clinicians' force application during joint mobilization. A systematic search of PubMed and EBSCO Host databases from inception to March 1, 2013 was conducted to identify studies assessing the reliability of force application during joint mobilizations. Two reviewers utilized the Quality Appraisal of Reliability Studies (QAREL) assessment tool to determine the quality of included studies. The relative reliability of the included studies was examined through intraclass correlation coefficients (ICC) to synthesize study findings. All results were collated qualitatively with a level of evidence approach. A total of seven studies met the eligibility and were included. Five studies were included that assessed inter-clinician reliability, and six studies were included that assessed intra-clinician reliability. The overall level of evidence for inter-clinician reliability was strong for poor-to-moderate reliability (ICC = -0.04 to 0.70). The overall level of evidence for intra-clinician reliability was strong for good reliability (ICC = 0.75-0.99). This systematic review indicates there is variability in force application between clinicians but individual clinicians apply forces consistently. The results of this systematic review suggest innovative instructional methods are needed to improve consistency and validate the forces applied during of joint mobilization treatments. This is particularly evident for improving the consistency of force application across clinicians. Copyright © 2014 Elsevier Ltd. All rights reserved.

  9. Reliability, Convergent Validity and Time Invariance of Default Mode Network Deviations in Early Adult Major Depressive Disorder.

    PubMed

    Bessette, Katie L; Jenkins, Lisanne M; Skerrett, Kristy A; Gowins, Jennifer R; DelDonno, Sophie R; Zubieta, Jon-Kar; McInnis, Melvin G; Jacobs, Rachel H; Ajilore, Olusola; Langenecker, Scott A

    2018-01-01

    There is substantial variability across studies of default mode network (DMN) connectivity in major depressive disorder, and reliability and time-invariance are not reported. This study evaluates whether DMN dysconnectivity in remitted depression (rMDD) is reliable over time and symptom-independent, and explores convergent relationships with cognitive features of depression. A longitudinal study was conducted with 82 young adults free of psychotropic medications (47 rMDD, 35 healthy controls) who completed clinical structured interviews, neuropsychological assessments, and 2 resting-state fMRI scans across 2 study sites. Functional connectivity analyses from bilateral posterior cingulate and anterior hippocampal formation seeds in DMN were conducted at both time points within a repeated-measures analysis of variance to compare groups and evaluate reliability of group-level connectivity findings. Eleven hyper- (from posterior cingulate) and 6 hypo- (from hippocampal formation) connectivity clusters in rMDD were obtained with moderate to adequate reliability in all but one cluster (ICC's range = 0.50 to 0.76 for 16 of 17). The significant clusters were reduced with a principle component analysis (5 components obtained) to explore these connectivity components, and were then correlated with cognitive features (rumination, cognitive control, learning and memory, and explicit emotion identification). At the exploratory level, for convergent validity, components consisting of posterior cingulate with cognitive control network hyperconnectivity in rMDD were related to cognitive control (inverse) and rumination (positive). Components consisting of anterior hippocampal formation with social emotional network and DMN hypoconnectivity were related to memory (inverse) and happy emotion identification (positive). Thus, time-invariant DMN connectivity differences exist early in the lifespan course of depression and are reliable. The nuanced results suggest a ventral within-network hypoconnectivity associated with poor memory and a dorsal cross-network hyperconnectivity linked to poorer cognitive control and elevated rumination. Study of early course remitted depression with attention to reliability and symptom independence could lead to more readily translatable clinical assessment tools for biomarkers.

  10. Reliability Stress-Strength Models for Dependent Observations with Applications in Clinical Trials

    NASA Technical Reports Server (NTRS)

    Kushary, Debashis; Kulkarni, Pandurang M.

    1995-01-01

    We consider the applications of stress-strength models in studies involving clinical trials. When studying the effects and side effects of certain procedures (treatments), it is often the case that observations are correlated due to subject effect, repeated measurements and observing many characteristics simultaneously. We develop maximum likelihood estimator (MLE) and uniform minimum variance unbiased estimator (UMVUE) of the reliability which in clinical trial studies could be considered as the chances of increased side effects due to a particular procedure compared to another. The results developed apply to both univariate and multivariate situations. Also, for the univariate situations we develop simple to use lower confidence bounds for the reliability. Further, we consider the cases when both stress and strength constitute time dependent processes. We define the future reliability and obtain methods of constructing lower confidence bounds for this reliability. Finally, we conduct simulation studies to evaluate all the procedures developed and also to compare the MLE and the UMVUE.

  11. Is One Trial Sufficient to Obtain Excellent Pressure Pain Threshold Reliability in the Low Back of Asymptomatic Individuals? A Test-Retest Study.

    PubMed

    Balaguier, Romain; Madeleine, Pascal; Vuillerme, Nicolas

    2016-01-01

    The assessment of pressure pain threshold (PPT) provides a quantitative value related to the mechanical sensitivity to pain of deep structures. Although excellent reliability of PPT has been reported in numerous anatomical locations, its absolute and relative reliability in the lower back region remains to be determined. Because of the high prevalence of low back pain in the general population and because low back pain is one of the leading causes of disability in industrialized countries, assessing pressure pain thresholds over the low back is particularly of interest. The purpose of this study study was (1) to evaluate the intra- and inter- absolute and relative reliability of PPT within 14 locations covering the low back region of asymptomatic individuals and (2) to determine the number of trial required to ensure reliable PPT measurements. Fifteen asymptomatic subjects were included in this study. PPTs were assessed among 14 anatomical locations in the low back region over two sessions separated by one hour interval. For the two sessions, three PPT assessments were performed on each location. Reliability was assessed computing intraclass correlation coefficients (ICC), standard error of measurement (SEM) and minimum detectable change (MDC) for all possible combinations between trials and sessions. Bland-Altman plots were also generated to assess potential bias in the dataset. Relative reliability for both intra- and inter- session was almost perfect with ICC ranged from 0.85 to 0.99. With respect to the intra-session, no statistical difference was reported for ICCs and SEM regardless of the conducted comparisons between trials. Conversely, for inter-session, ICCs and SEM values were significantly larger when two consecutive PPT measurements were used for data analysis. No significant difference was observed for the comparison between two consecutive measurements and three measurements. Excellent relative and absolute reliabilities were reported for both intra- and inter-session. Reliable measurements can be equally achieved when using the mean of two or three consecutive PPT measurements, as usually proposed in the literature, or with only the first one. Although reliability was almost perfect regardless of the conducted comparison between PPT assessments, our results suggest using two consecutive measurements to obtain higher short term absolute reliability.

  12. Validity and Reliability Study of the Self-Efficacy Scale in Rendering Piano Education to Children of 6-12 Years

    ERIC Educational Resources Information Center

    Ekinci, Hatice

    2014-01-01

    This study was conducted in order to develop a valid and reliable scale that can be used in measuring self-efficacy of candidate music teachers in rendering piano education to children of 6-12 years. To this end, a pool of 51 items was created by using the literature, and taking the opinions of piano professors and piano instructors working with…

  13. Development and reliability of an audit tool to assess the school physical activity environment across 12 countries

    PubMed Central

    Broyles, S T; Drazba, K T; Church, T S; Chaput, J-P; Fogelholm, M; Hu, G; Kuriyan, R; Kurpad, A; Lambert, E V; Maher, C; Maia, J; Matsudo, V; Olds, T; Onywera, V; Sarmiento, O L; Standage, M; Tremblay, M S; Tudor-Locke, C; Zhao, P; Katzmarzyk, P T

    2015-01-01

    Objectives: Schools are an important setting to enable and promote physical activity. Researchers have created a variety of tools to perform objective environmental assessments (or ‘audits') of other settings, such as neighborhoods and parks; yet, methods to assess the school physical activity environment are less common. The purpose of this study is to describe the approach used to objectively measure the school physical activity environment across 12 countries representing all inhabited continents, and to report on the reliability and feasibility of this methodology across these diverse settings. Methods: The International Study of Childhood Obesity, Lifestyle and the Environment (ISCOLE) school audit tool (ISAT) data collection required an in-depth training (including field practice and certification) and was facilitated by various supporting materials. Certified data collectors used the ISAT to assess the environment of all schools enrolled in ISCOLE. Sites completed a reliability audit (simultaneous audits by two independent, certified data collectors) for a minimum of two schools or at least 5% of their school sample. Item-level agreement between data collectors was assessed with both the kappa statistic and percent agreement. Inter-rater reliability of school summary scores was measured using the intraclass correlation coefficient. Results: Across the 12 sites, 256 schools participated in ISCOLE. Reliability audits were conducted at 53 schools (20.7% of the sample). For the assessed environmental features, inter-rater reliability (kappa) ranged from 0.37 to 0.96; 18 items (42%) were assessed with almost perfect reliability (κ=0.80–0.96), and a further 24 items (56%) were assessed with substantial reliability (κ=0.61–0.79). Likewise, scores that summarized a school's support for physical activity were highly reliable, with the exception of scores assessing aesthetics and perceived suitability of the school grounds for sport, informal games and general play. Conclusions: This study suggests that the ISAT can be used to conduct reliable objective audits of the school physical activity environment across diverse, international school settings. PMID:27152183

  14. Interrater reliability of the cervicothoracic and shoulder physical examination in patients with a primary complaint of shoulder pain.

    PubMed

    Burns, Scott A; Cleland, Joshua A; Carpenter, Kristin; Mintken, Paul E

    2016-03-01

    Examine the interrater reliability of cervicothoracic and shoulder physical examination in patients with a primary complaint of shoulder pain. Single-group repeated-measures design for interrater reliability. Orthopaedic physical therapy clinics. Twenty-one patients with a primary complaint of shoulder pain underwent a standardized examination by a physical therapist (PT). A PT conducted the first examination and one of two additional PTs conducted the 2nd examination. The Cohen κ and weighted κ were used to calculate the interrater reliability of ordinal level data. Intraclass correlation coefficients model 2,1 (ICC2,1) and the 95% confidence intervals were calculated to determine the interrater reliability. The kappa coefficients ranged from -.24 to .83 for the mobility assessment of the glenohumeral, acromioclavicular and sternoclavicular joints. The kappa coefficients ranged from -.20 to .58 for joint mobility assessment of the cervical and thoracic spine. The kappa coefficients ranged from .23 to 1.0 for special tests of the shoulder and cervical spine. The present study reported the reliability of a comprehensive upper quarter physical examination for a group of patients with a primary report of shoulder pain. The reliability varied considerably for the cervical and shoulder examination and was significantly higher for the examination of muscle length and cervical range of motion. Copyright © 2015 Elsevier Ltd. All rights reserved.

  15. Measuring Educators' Attitudes and Beliefs about Evaluation: Construct Validity and Reliability of the Teacher Evaluation Experience Scale

    ERIC Educational Resources Information Center

    Reddy, Linda A.; Dudek, Christopher M.; Kettler, Ryan J.; Kurz, Alexander; Peters, Stephanie

    2016-01-01

    This study presents the reliability and validity of the Teacher Evaluation Experience Scale--Teacher Form (TEES-T), a multidimensional measure of educators' attitudes and beliefs about teacher evaluation. Confirmatory factor analyses of data from 583 teachers were conducted on the TEES-T hypothesized five-factor model, as well as on alternative…

  16. A Study to Identify and Analyze the Effects of Category and Frequency Sampling on the Reporting of Total Nursing Care Hour Requirements

    DTIC Science & Technology

    1989-06-26

    quarterly basis as a means to validate inter-rater reliability. Reliability testing will be conducted by an Independent, expert patient classifier...appointed by nursing administrat’on (Vail, Norton, & Rimm, 1984). An independent, expert patient classifier is defined as an RN not assigned to the unit

  17. An Attitude Scale on Individual Instrument and Individual Instrument Course: Validity-Reliability Research

    ERIC Educational Resources Information Center

    Kuçukosmanoglu, Hayrettin Onur

    2015-01-01

    The main purpose of this study is to develop a scale to determine students' attitude levels on individual instruments and individual instrument courses in instrument training, which is an important dimension of music education, and to conduct a validity-reliability research of the scale that has been developed. The scale consists of 16 items. The…

  18. A preliminary study of wildland fire pattern indicator reliability following an experimental fire

    Treesearch

    Albert Simeoni; Zachary C. Owens; Erik W. Christiansen; Abid Kemal; Michael Gallagher; Kenneth L. Clark; Nicholas Skowronski; Eric V. Mueller; Jan C. Thomas; Simon Santamaria; Rory M. Hadden

    2017-01-01

    An experimental fire was conducted in 2016, in the Pinelands National Reserve of New Jersey, to assess the reliability of the fire pattern indicators used in wildland fire investigation. Objects were planted in the burn area to support the creation of the indicators. Fuel properties and environmental data were recorded. Video and infrared cameras were used to document...

  19. A Mixed-methods Study to Assess Interrater Reliability and Nurse Perception of the Braden Scale in a Tertiary Acute Care Setting.

    PubMed

    Ho, Chester H; Cheung, Amanda; Southern, Danielle; Ocampo, Wrechelle; Kaufman, Jaime; Hogan, David B; Baylis, Barry; Conly, John M; Stelfox, Henry T; Ghali, William A

    2016-12-01

    Research regarding the reliability of the Braden Scale and nurses' perspectives on the instrument for predicting pressure ulcer (PU) risk in acute care settings is limited. A mixed-methods study was conducted in a tertiary acute care facility to examine interrater reliability (IRR) of the Braden Scale and its subscales, and a qualitative survey using semi-structured interviews was conducted among nurses caring for patients in acute care units to gain nurse perspective regarding scale usability. Data were extracted from a previous retrospective, randomized, controlled trial involving adult patients with compromised mobility receiving care in a tertiary acute care hospital in Canada. One-way, intraclass correlation coefficients (ICCs) were calculated on item and total scores, and kappa statistics were used to determine reliability of categorizing patients on their risk. Interview results were categorized by common themes. Reliability was assessed on 64 patients, where nurses and research staff independently assessed enrolled participants at baseline and after 72 hours using the Braden Scale as it appeared on an electronic medical record. IRR for the total score was high (ICC = 0.807). The friction and shear item had the lowest reliability (ICC = 0.266). Reliability of categorizing patients' level of risk had moderate agreement (κ = 0.408). Three (3) major and 12 subthemes emerged from the 14 nurse interviews; nurses were aware of the scale's purpose but were uncertain of its effectiveness, some items were difficult to rate, and questions were raised as to whether using the scale enhanced patient care. Aspects identified by nurses to enhance usability included: 1) changes to the electronic version (incorporating the scale into daily assessment documents with readily available item descriptions), 2) additional training, and 3) easily available resource material to improve reliability and usability of scale. These findings need to be considered when using the Braden Scale in clinical practice. Further study of the value of the total Braden Scale and its subscales is warranted.

  20. A systematic review of publications assessing reliability and validity of the Behavioral Risk Factor Surveillance System (BRFSS), 2004–2011

    PubMed Central

    2013-01-01

    Background In recent years response rates on telephone surveys have been declining. Rates for the behavioral risk factor surveillance system (BRFSS) have also declined, prompting the use of new methods of weighting and the inclusion of cell phone sampling frames. A number of scholars and researchers have conducted studies of the reliability and validity of the BRFSS estimates in the context of these changes. As the BRFSS makes changes in its methods of sampling and weighting, a review of reliability and validity studies of the BRFSS is needed. Methods In order to assess the reliability and validity of prevalence estimates taken from the BRFSS, scholarship published from 2004–2011 dealing with tests of reliability and validity of BRFSS measures was compiled and presented by topics of health risk behavior. Assessments of the quality of each publication were undertaken using a categorical rubric. Higher rankings were achieved by authors who conducted reliability tests using repeated test/retest measures, or who conducted tests using multiple samples. A similar rubric was used to rank validity assessments. Validity tests which compared the BRFSS to physical measures were ranked higher than those comparing the BRFSS to other self-reported data. Literature which undertook more sophisticated statistical comparisons was also ranked higher. Results Overall findings indicated that BRFSS prevalence rates were comparable to other national surveys which rely on self-reports, although specific differences are noted for some categories of response. BRFSS prevalence rates were less similar to surveys which utilize physical measures in addition to self-reported data. There is very little research on reliability and validity for some health topics, but a great deal of information supporting the validity of the BRFSS data for others. Conclusions Limitations of the examination of the BRFSS were due to question differences among surveys used as comparisons, as well as mode of data collection differences. As the BRFSS moves to incorporating cell phone data and changing weighting methods, a review of reliability and validity research indicated that past BRFSS landline only data were reliable and valid as measured against other surveys. New analyses and comparisons of BRFSS data which include the new methodologies and cell phone data will be needed to ascertain the impact of these changes on estimates in the future. PMID:23522349

  1. Reliability and construct validity of the Malay version of the Job Content Questionnaire (JCQ) among secondary school teachers in Kota Bharu, Kelantan, Malaysia.

    PubMed

    Hadi, Azlihanis Abdul; Naing, Nyi Nyi; Daud, Aziah; Nordin, Rusli

    2006-11-01

    This study was conducted to assess the reliability and construct validity of the Malay version of Job Content Questionnaire (JCQ) among secondary school teachers in Kota Bharu, Kelantan. A total of 68 teachers consented to participate in the study and were administered the Malay version of JCQ. Reliability was determined using Cronbach's alpha for internal consistency whilst construct validity was assessed using factor analysis. The results indicated that Cronbach's alpha coefficients revealed decision latitude (0.75), psychological job demand (0.50) and social support (0.84). Factor analysis showed three meaningful common factors that could explain the construct of Karasek's demand-control-social support model. The study suggests the JCQ scales are reliable and valid tools for assessing job stress in school teachers.

  2. A study of software standards used in the avionics industry

    NASA Technical Reports Server (NTRS)

    Hayhurst, Kelly J.

    1994-01-01

    Within the past decade, software has become an increasingly common element in computing systems. In particular, the role of software used in the aerospace industry, especially in life- or safety-critical applications, is rapidly expanding. This intensifies the need to use effective techniques for achieving and verifying the reliability of avionics software. Although certain software development processes and techniques are mandated by government regulating agencies, no one methodology has been shown to consistently produce reliable software. The knowledge base for designing reliable software simply has not reached the maturity of its hardware counterpart. In an effort to increase our understanding of software, the Langley Research Center conducted a series of experiments over 15 years with the goal of understanding why and how software fails. As part of this program, the effectiveness of current industry standards for the development of avionics is being investigated. This study involves the generation of a controlled environment to conduct scientific experiments on software processes.

  3. Content validity and test-retest reliability of a low back pain questionnaire in Zimbabwean adolescents.

    PubMed

    Chiwaridzo, Matthew; Chikasha, Tafadzwa Nicole; Naidoo, Nirmala; Dambi, Jermaine Matewu; Tadyanemhandu, Cathrine; Munambah, Nyaradzai; Chizanga, Precious Trish

    2017-01-01

    In Zimbabwe, a recent increase in the volume of research on recurrent non-specific low back pain (NSLBP) has revealed that adolescents are commonly affected. This is alarming to health professionals and parents and calls for serious primary preventative strategies to be developed and implemented forthwith. Early identification initiatives should be prioritised in order to curtail the condition and its progression. In an attempt to be proactive in minimising the prevalence of recurrent NSLBP, this study was conducted to evaluate the content validity and test-retest reliability of a survey questionnaire with the aim of proffering a valid and reliable questionnaire which can be used in non-clinical settings to identify adolescents with recurrent NSLBP in Harare, Zimbabwe and determine the possible factors associated with the condition. The study was conducted in two parts. The first part assessed content validity of the questionnaire using four experts derived from academia and clinical practice. The second part evaluated the reliability of the questionnaire among 125 high school-children aged between 13 and 19 years in a test-retest study. Twenty-six (26) out of thirty questions in the questionnaire had an Item Content Validity index of 1.00, demonstrating complete agreement among content experts. Overall, the Scale Content Validity Index for the questionnaire was 0.97. Item completion for the reliability study was satisfactory. The questionnaire items had kappa values ranging from 0.17 (slight agreement) to 1 (perfect agreement). High levels of reliability were found for the questions on school bag use ( k =0.94), sports participation ( k =0.97), and lifetime prevalence ( k =0.89). Excellent content validity and slight to perfect test-retest reliability was found for the Low Back Pain (LBP) questionnaire. These results are comparable to findings of other studies evaluating the psychometric properties of LBP questionnaires. Cognisant of the limitations of the study, the results of this study suggest that the LBP questionnaire could be used in local studies investigating LBP among adolescents although questions enquiring on functional limitations and sciatica may need further consideration.

  4. Inter-rater and intra-rater reliability of the Bahasa Melayu version of Rose Angina Questionnaire.

    PubMed

    Hassan, N B; Choudhury, S R; Naing, L; Conroy, R M; Rahman, A R A

    2007-01-01

    The objective of the study is to translate the Rose Questionnaire (RQ) into a Bahasa Melayu version and adapt it cross-culturally, and to measure its inter-rater and intrarater reliability. This cross sectional study was conducted in the respondents' homes or workplaces in Kelantan, Malaysia. One hundred respondents aged 30 and above with different socio-demographic status were interviewed for face validity. For each inter-rater and intra-rater reliability, a sample of 150 respondents was interviewed. Inter-rater and intra-rater reliabilities were assessed by Cohen's kappa. The overall inter-rater agreements by the five pair of interviewers at point one and two were 0.86, and intrarater reliability by the five interviewers on the seven-item questionnaire at poinone and two was 0.88, as measured by kappa coefficient. The translated Malay version of RQ demonstrated an almost perfect inter-rater and intra-rater reliability and further validation such as sensitivity and specificity analysis of this translated questionnaire is highly recommended.

  5. Reliability and validity of the revised Gibson Test of Cognitive Skills, a computer-based test battery for assessing cognition across the lifespan.

    PubMed

    Moore, Amy Lawson; Miller, Terissa M

    2018-01-01

    The purpose of the current study is to evaluate the validity and reliability of the revised Gibson Test of Cognitive Skills, a computer-based battery of tests measuring short-term memory, long-term memory, processing speed, logic and reasoning, visual processing, as well as auditory processing and word attack skills. This study included 2,737 participants aged 5-85 years. A series of studies was conducted to examine the validity and reliability using the test performance of the entire norming group and several subgroups. The evaluation of the technical properties of the test battery included content validation by subject matter experts, item analysis and coefficient alpha, test-retest reliability, split-half reliability, and analysis of concurrent validity with the Woodcock Johnson III Tests of Cognitive Abilities and Tests of Achievement. Results indicated strong sources of evidence of validity and reliability for the test, including internal consistency reliability coefficients ranging from 0.87 to 0.98, test-retest reliability coefficients ranging from 0.69 to 0.91, split-half reliability coefficients ranging from 0.87 to 0.91, and concurrent validity coefficients ranging from 0.53 to 0.93. The Gibson Test of Cognitive Skills-2 is a reliable and valid tool for assessing cognition in the general population across the lifespan.

  6. Assessing local instrument reliability and validity: a field-based example from northern Uganda.

    PubMed

    Betancourt, Theresa S; Bass, Judith; Borisova, Ivelina; Neugebauer, Richard; Speelman, Liesbeth; Onyango, Grace; Bolton, Paul

    2009-08-01

    This paper presents an approach for evaluating the reliability and validity of mental health measures in non-Western field settings. We describe this approach using the example of our development of the Acholi psychosocial assessment instrument (APAI), which is designed to assess depression-like (two tam, par and kumu), anxiety-like (ma lwor) and conduct problems (kwo maraco) among war-affected adolescents in northern Uganda. To examine the criterion validity of this measure in the absence of a traditional gold standard, we derived local syndrome terms from qualitative data and used self reports of these syndromes by indigenous people as a reference point for determining caseness. Reliability was examined using standard test-retest and inter-rater methods. Each of the subscale scores for the depression-like syndromes exhibited strong internal reliability ranging from alpha = 0.84-0.87. Internal reliability was good for anxiety (0.70), conduct problems (0.83), and the pro-social attitudes and behaviors (0.70) subscales. Combined inter-rater reliability and test-retest reliability were good for most subscales except for the conduct problem scale and prosocial scales. The pattern of significant mean differences in the corresponding APAI problem scale score between self-reported cases vs. noncases on local syndrome terms was confirmed in the data for all of the three depression-like syndromes, but not for the anxiety-like syndrome ma lwor or the conduct problem kwo maraco.

  7. The Bahasa Melayu version of the Nursing Stress Scale among nurses: a reliability study in Malaysia.

    PubMed

    Rosnawati, Muhamad Robat; Moe, Htay; Masilamani, Retneswari; Darus, A

    2010-10-01

    The Nursing Stress Scale (NSS) has been shown to be a valid and reliable instrument to assess occupational stressors among nurses. The NSS, which was previously used in the English version, was translated and back-translated into Bahasa Melayu. This study was conducted to assess the reliability of the Bahasa Melayu version of the NSS among nurses for future studies in this country. The reliability of the NSS was assessed after its readministration to 30 nurses with a 2-week interval. The Spearman coefficient was calculated to assess its stability. The internal consistency was measured through 4 measures: Cronbach's α, Spearman-Brown, Guttman split-half, and standardized item α coefficients. The total response rate was 70%. Test-retest reliability showed remarkable stability (Spearman's ρ exceeded .70). All 4 measures of internal consistency among items indicated a satisfactory level (coefficients in the range of .68 to .87). In conclusion, the Bahasa Melayu version of the NSS is a reliable and useful instrument for measuring the possible stressors at the workplace among nurses.

  8. A framework for conducting mechanistic based reliability assessments of components operating in complex systems

    NASA Astrophysics Data System (ADS)

    Wallace, Jon Michael

    2003-10-01

    Reliability prediction of components operating in complex systems has historically been conducted in a statistically isolated manner. Current physics-based, i.e. mechanistic, component reliability approaches focus more on component-specific attributes and mathematical algorithms and not enough on the influence of the system. The result is that significant error can be introduced into the component reliability assessment process. The objective of this study is the development of a framework that infuses the needs and influence of the system into the process of conducting mechanistic-based component reliability assessments. The formulated framework consists of six primary steps. The first three steps, identification, decomposition, and synthesis, are primarily qualitative in nature and employ system reliability and safety engineering principles to construct an appropriate starting point for the component reliability assessment. The following two steps are the most unique. They involve a step to efficiently characterize and quantify the system-driven local parameter space and a subsequent step using this information to guide the reduction of the component parameter space. The local statistical space quantification step is accomplished using two proposed multivariate probability models: Multi-Response First Order Second Moment and Taylor-Based Inverse Transformation. Where existing joint probability models require preliminary distribution and correlation information of the responses, these models combine statistical information of the input parameters with an efficient sampling of the response analyses to produce the multi-response joint probability distribution. Parameter space reduction is accomplished using Approximate Canonical Correlation Analysis (ACCA) employed as a multi-response screening technique. The novelty of this approach is that each individual local parameter and even subsets of parameters representing entire contributing analyses can now be rank ordered with respect to their contribution to not just one response, but the entire vector of component responses simultaneously. The final step of the framework is the actual probabilistic assessment of the component. Although the same multivariate probability tools employed in the characterization step can be used for the component probability assessment, variations of this final step are given to allow for the utilization of existing probabilistic methods such as response surface Monte Carlo and Fast Probability Integration. The overall framework developed in this study is implemented to assess the finite-element based reliability prediction of a gas turbine airfoil involving several failure responses. Results of this implementation are compared to results generated using the conventional 'isolated' approach as well as a validation approach conducted through large sample Monte Carlo simulations. The framework resulted in a considerable improvement to the accuracy of the part reliability assessment and an improved understanding of the component failure behavior. Considerable statistical complexity in the form of joint non-normal behavior was found and accounted for using the framework. Future applications of the framework elements are discussed.

  9. Design of Chemical Literacy Assessment by Using Model of Educational Reconstruction (MER) on Solubility Topic

    NASA Astrophysics Data System (ADS)

    Yusmaita, E.; Nasra, Edi

    2018-04-01

    This research aims to produce instrument for measuring chemical literacy assessment in basic chemistry courses with solubility topic. The construction of this measuring instrument is adapted to the PISA (Programme for International Student Assessment) problem’s characteristics and the Syllaby of Basic Chemistry in KKNI-IndonesianNational Qualification Framework. The PISA is a cross-country study conducted periodically to monitor the outcomes of learners' achievement in each participating country. So far, studies conducted by PISA include reading literacy, mathematic literacy and scientific literacy. Refered to the scientific competence of the PISA study on science literacy, an assessment designed to measure the chemical literacy of the chemistry department’s students in UNP. The research model used is MER (Model of Educational Reconstruction). The validity and reliability values of discourse questions is measured using the software ANATES. Based on the acquisition of these values is obtained a valid and reliable chemical literacy questions.There are seven question items limited response on the topic of solubility with valid category, the acquisition value of test reliability is 0,86, and has a difficulty index and distinguishing good

  10. Reliability of self-reported antisocial personality disorder symptoms among substance abusers.

    PubMed

    Cottler, L B; Compton, W M; Ridenour, T A; Ben Abdallah, A; Gallagher, T

    1998-02-01

    It is estimated that from 20 to 60% of substance abusers meet criteria for Antisocial Personality Disorder (APD). An accurate and reliable diagnosis is important because persons meeting criteria for APD, by the nature of their disorder, are less likely to change behaviors and more likely to relapse to both substance abuse and high risk behaviors. To understand more about the reliability of the disorder and symptoms of APD, the Diagnostic Interview Schedule Version III-R (DIS) was administered to 453 substance abusers ascertained from treatment programs and from the general population (St Louis Epidemiological Catchment Area (ECA) follow-up study). Estimates of the 1 week, test-retest reliability for the childhood conduct disorder criterion, the adult antisocial behavior criterion, and APD diagnosis fell in the good agreement range, as measured by kappa. The internal consistency of these DIS symptoms was adequate to acceptable. Individual DIS criteria designed to measure childhood conduct disorder ranged from fair to good for most items; reliability was slightly higher for the adult antisocial behavior symptom items. Finally, self-reported 'liars' were no more unreliable in their reports of their behaviors than 'non-liars'.

  11. Scheduling for energy and reliability management on multiprocessor real-time systems

    NASA Astrophysics Data System (ADS)

    Qi, Xuan

    Scheduling algorithms for multiprocessor real-time systems have been studied for years with many well-recognized algorithms proposed. However, it is still an evolving research area and many problems remain open due to their intrinsic complexities. With the emergence of multicore processors, it is necessary to re-investigate the scheduling problems and design/develop efficient algorithms for better system utilization, low scheduling overhead, high energy efficiency, and better system reliability. Focusing cluster schedulings with optimal global schedulers, we study the utilization bound and scheduling overhead for a class of cluster-optimal schedulers. Then, taking energy/power consumption into consideration, we developed energy-efficient scheduling algorithms for real-time systems, especially for the proliferating embedded systems with limited energy budget. As the commonly deployed energy-saving technique (e.g. dynamic voltage frequency scaling (DVFS)) will significantly affect system reliability, we study schedulers that have intelligent mechanisms to recuperate system reliability to satisfy the quality assurance requirements. Extensive simulation is conducted to evaluate the performance of the proposed algorithms on reduction of scheduling overhead, energy saving, and reliability improvement. The simulation results show that the proposed reliability-aware power management schemes could preserve the system reliability while still achieving substantial energy saving.

  12. Software reliability studies

    NASA Technical Reports Server (NTRS)

    Wilson, Larry W.

    1989-01-01

    The longterm goal of this research is to identify or create a model for use in analyzing the reliability of flight control software. The immediate tasks addressed are the creation of data useful to the study of software reliability and production of results pertinent to software reliability through the analysis of existing reliability models and data. The completed data creation portion of this research consists of a Generic Checkout System (GCS) design document created in cooperation with NASA and Research Triangle Institute (RTI) experimenters. This will lead to design and code reviews with the resulting product being one of the versions used in the Terminal Descent Experiment being conducted by the Systems Validations Methods Branch (SVMB) of NASA/Langley. An appended paper details an investigation of the Jelinski-Moranda and Geometric models for software reliability. The models were given data from a process that they have correctly simulated and asked to make predictions about the reliability of that process. It was found that either model will usually fail to make good predictions. These problems were attributed to randomness in the data and replication of data was recommended.

  13. Measuring the Environment for Friendliness Toward Physical Activity: A Comparison of the Reliability of 3 Questionnaires

    PubMed Central

    Brownson, Ross C.; Chang, Jen Jen; Eyler, Amy A.; Ainsworth, Barbara E.; Kirtland, Karen A.; Saelens, Brian E.; Sallis, James F.

    2004-01-01

    Objectives. We tested the reliability of 3 instruments that assessed social and physical environments. Methods. We conducted a test–retest study among US adults (n = 289). We used telephone survey methods to measure suitableness of the perceived (vs objective) environment for recreational physical activity and nonmotorized transportation. Results. Most questions in our surveys that attempted to measure specific characteristics of the built environment showed moderate to high reliability. Questions about the social environment showed lower reliability than those that assessed the physical environment. Certain blocks of questions appeared to be selectively more reliable for urban or rural respondents. Conclusions. Despite differences in content and in response formats, all 3 surveys showed evidence of reliability, and most items are now ready for use in research and in public health surveillance. PMID:14998817

  14. Statistical modeling of software reliability

    NASA Technical Reports Server (NTRS)

    Miller, Douglas R.

    1992-01-01

    This working paper discusses the statistical simulation part of a controlled software development experiment being conducted under the direction of the System Validation Methods Branch, Information Systems Division, NASA Langley Research Center. The experiment uses guidance and control software (GCS) aboard a fictitious planetary landing spacecraft: real-time control software operating on a transient mission. Software execution is simulated to study the statistical aspects of reliability and other failure characteristics of the software during development, testing, and random usage. Quantification of software reliability is a major goal. Various reliability concepts are discussed. Experiments are described for performing simulations and collecting appropriate simulated software performance and failure data. This data is then used to make statistical inferences about the quality of the software development and verification processes as well as inferences about the reliability of software versions and reliability growth under random testing and debugging.

  15. Validity and reliability of Internet-based physiotherapy assessment for musculoskeletal disorders: a systematic review.

    PubMed

    Mani, Suresh; Sharma, Shobha; Omar, Baharudin; Paungmali, Aatit; Joseph, Leonard

    2017-04-01

    Purpose The purpose of this review is to systematically explore and summarise the validity and reliability of telerehabilitation (TR)-based physiotherapy assessment for musculoskeletal disorders. Method A comprehensive systematic literature review was conducted using a number of electronic databases: PubMed, EMBASE, PsycINFO, Cochrane Library and CINAHL, published between January 2000 and May 2015. The studies examined the validity, inter- and intra-rater reliabilities of TR-based physiotherapy assessment for musculoskeletal conditions were included. Two independent reviewers used the Quality Appraisal Tool for studies of diagnostic Reliability (QAREL) and the Quality Assessment of Diagnostic Accuracy Studies (QUADAS) tool to assess the methodological quality of reliability and validity studies respectively. Results A total of 898 hits were achieved, of which 11 articles based on inclusion criteria were reviewed. Nine studies explored the concurrent validity, inter- and intra-rater reliabilities, while two studies examined only the concurrent validity. Reviewed studies were moderate to good in methodological quality. The physiotherapy assessments such as pain, swelling, range of motion, muscle strength, balance, gait and functional assessment demonstrated good concurrent validity. However, the reported concurrent validity of lumbar spine posture, special orthopaedic tests, neurodynamic tests and scar assessments ranged from low to moderate. Conclusion TR-based physiotherapy assessment was technically feasible with overall good concurrent validity and excellent reliability, except for lumbar spine posture, orthopaedic special tests, neurodynamic testa and scar assessment.

  16. Developing and validating the Youth Conduct Problems Scale-Rwanda: a mixed methods approach.

    PubMed

    Ng, Lauren C; Kanyanganzi, Frederick; Munyanah, Morris; Mushashi, Christine; Betancourt, Theresa S

    2014-01-01

    This study developed and validated the Youth Conduct Problems Scale-Rwanda (YCPS-R). Qualitative free listing (n = 74) and key informant interviews (n = 47) identified local conduct problems, which were compared to existing standardized conduct problem scales and used to develop the YCPS-R. The YCPS-R was cognitive tested by 12 youth and caregiver participants, and assessed for test-retest and inter-rater reliability in a sample of 64 youth. Finally, a purposive sample of 389 youth and their caregivers were enrolled in a validity study. Validity was assessed by comparing YCPS-R scores to conduct disorder, which was diagnosed with the Mini International Neuropsychiatric Interview for Children, and functional impairment scores on the World Health Organization Disability Assessment Schedule Child Version. ROC analyses assessed the YCPS-R's ability to discriminate between youth with and without conduct disorder. Qualitative data identified a local presentation of youth conduct problems that did not match previously standardized measures. Therefore, the YCPS-R was developed solely from local conduct problems. Cognitive testing indicated that the YCPS-R was understandable and required little modification. The YCPS-R demonstrated good reliability, construct, criterion, and discriminant validity, and fair classification accuracy. The YCPS-R is a locally-derived measure of Rwandan youth conduct problems that demonstrated good psychometric properties and could be used for further research.

  17. Assessment of Interobserver Reliability in Nutrition Studies that Use Direct Observation of School Meals

    PubMed Central

    BAGLIO, MICHELLE L.; BAXTER, SUZANNE DOMEL; GUINN, CAROLINE H.; THOMPSON, WILLIAM O.; SHAFFER, NICOLE M.; FRYE, FRANCESCA H. A.

    2005-01-01

    This article (a) provides a general review of interobserver reliability (IOR) and (b) describes our method for assessing IOR for items and amounts consumed during school meals for a series of studies regarding the accuracy of fourth-grade children's dietary recalls validated with direct observation of school meals. A widely used validation method for dietary assessment is direct observation of meals. Although many studies utilize several people to conduct direct observations, few published studies indicate whether IOR was assessed. Assessment of IOR is necessary to determine that the information collected does not depend on who conducted the observation. Two strengths of our method for assessing IOR are that IOR was assessed regularly throughout the data collection period and that IOR was assessed for foods at the item and amount level instead of at the nutrient level. Adequate agreement among observers is essential to the reasoning behind using observation as a validation tool. Readers are encouraged to question the results of studies that fail to mention and/or to include the results for assessment of IOR when multiple people have conducted observations. PMID:15354155

  18. The TiltMeter app is a novel and accurate measurement tool for the weight bearing lunge test.

    PubMed

    Williams, Cylie M; Caserta, Antoni J; Haines, Terry P

    2013-09-01

    The weight bearing lunge test is increasing being used by health care clinicians who treat lower limb and foot pathology. This measure is commonly established accurately and reliably with the use of expensive equipment. This study aims to compare the digital inclinometer with a free app, TiltMeter on an Apple iPhone. This was an intra-rater and inter-rater reliability study. Two raters (novice and experienced) conducted the measurements in both a bent knee and straight leg position to determine the intra-rater and inter-rater reliability. Concurrent validity was also established. Allied health practitioners were recruited as participants from the workplace. A preconditioning stretch was conducted and the ankle range of motion was established with the weight bearing lunge test position with firstly the leg straight and secondly with the knee bent. The measurement device and each participant were randomised during measurement. The intra-rater reliability and inter-rater reliability for the devices and in both positions were all over ICC 0.8 except for one intra-rater measure (Digital inclinometer, novice, ICC 0.65). The inter-rater reliability between the digital inclinometer and the tilmeter was near perfect, ICC 0.96 (CI: 0.898-0.983); Concurrent validity ICC between the two devices was 0.83 (CI: -0.740 to 0.445). The use of the Tiltmeter app on the iPhone is a reliable and inexpensive tool to measure the available ankle range of motion. Health practitioners should use caution in applying these findings to other smart phone equipment if surface areas are not comparable. Crown Copyright © 2013. Published by Elsevier Ltd. All rights reserved.

  19. Are Bibliographic Management Software Search Interfaces Reliable?: A Comparison between Search Results Obtained Using Database Interfaces and the EndNote Online Search Function

    ERIC Educational Resources Information Center

    Fitzgibbons, Megan; Meert, Deborah

    2010-01-01

    The use of bibliographic management software and its internal search interfaces is now pervasive among researchers. This study compares the results between searches conducted in academic databases' search interfaces versus the EndNote search interface. The results show mixed search reliability, depending on the database and type of search…

  20. Reliability of Chinese medicine diagnostic variables in the examination of patients with osteoarthritis of the knee.

    PubMed

    Hua, Bin; Abbas, Estelle; Hayes, Alan; Ryan, Peter; Nelson, Lisa; O'Brien, Kylie

    2012-11-01

    Chinese medicine (CM) has its own diagnostic indicators that are used as evidence of change in a patient's condition. The majority of studies investigating efficacy of Chinese herbal medicine (CHM) have utilized biomedical diagnostic endpoints. For CM clinical diagnostic variables to be incorporated into clinical trial designs, there would need to be evidence that these diagnostic variables are reliable. Previous studies have indicated that the reliability of CM syndrome diagnosis is variable. Little information is known about where the variability stems from--the basic data collection level or the synthesis of diagnostic data, or both. No previous studies have investigated systematically the reliability of all four diagnostic methods used in the CM diagnostic process (Inquiry, Inspection, Auscultation/Olfaction, and Palpation). The objective of this study was to assess the inter-rater reliability of data collected using the four diagnostic methods of CM in Australian patients with knee osteoarthritis (OA), in order to investigate if CM variables could be used with confidence as diagnostic endpoints in a clinical trial investigating the efficacy of a CHM in treating OA. An inter-rater reliability study was conducted as a substudy of a clinical trial investigating the treatment of knee OA with Chinese herbal medicine. Two (2) experienced CM practitioners conducted a CM examination separately, within 2 hours of each other, in 40 participants. A CM assessment form was utilized to record the diagnostic data. Cohen's κ coefficient was used as a measure of the level of agreement between 2 practitioners. There was a relatively good level of agreement for Inquiry and Auscultation variables, and, in general, a low level of agreement for (visual) Inspection and Palpation variables. There was variation in the level of agreement between 2 practitioners on clinical information collected using the Four Diagnostic Methods of a CM examination. Some aspects of CM diagnosis appear to be reliable, while others are not. Based on these results, it was inappropriate to use CM diagnostic variables as diagnostic endpoints in the main study, which was an investigation of efficacy of CHM treatment of knee OA.

  1. Establishing survey validity and reliability for American Indians through "think aloud" and test-retest methods.

    PubMed

    Hauge, Cindy Horst; Jacobs-Knight, Jacque; Jensen, Jamie L; Burgess, Katherine M; Puumala, Susan E; Wilton, Georgiana; Hanson, Jessica D

    2015-06-01

    The purpose of this study was to use a mixed-methods approach to determine the validity and reliability of measurements used within an alcohol-exposed pregnancy prevention program for American Indian women. To develop validity, content experts provided input into the survey measures, and a "think aloud" methodology was conducted with 23 American Indian women. After revising the measurements based on this input, a test-retest was conducted with 79 American Indian women who were randomized to complete either the original measurements or the new, modified measurements. The test-retest revealed that some of the questions performed better for the modified version, whereas others appeared to be more reliable for the original version. The mixed-methods approach was a useful methodology for gathering feedback on survey measurements from American Indian participants and in indicating specific survey questions that needed to be modified for this population. © The Author(s) 2015.

  2. The reliability of physical examination tests for the clinical assessment of scapular dyskinesis in subjects with shoulder complaints: A systematic review.

    PubMed

    Lange, Toni; Struyf, Filip; Schmitt, Jochen; Lützner, Jörg; Kopkow, Christian

    2017-07-01

    Systematic review. The aim of this systematic review was to summarize and evaluate intra- and interrater reliability research of physical examination tests used for the assessment of scapular dyskinesis. Scapular dyskinesis, defined as alteration of normal scapular kinematics, is described as a non-specific response to different shoulder pathologies. A systematic literature search was conducted in MEDLINE, EMBASE, AMED and PEDro until March 20th, 2015. Methodological quality was assessed with the Quality Appraisal of Reliability Studies (QAREL) by two independent reviewers. The search strategy revealed 3259 articles, of which 15 met the inclusion criteria. These studies evaluated the reliability of 41 test and test variations used for the assessment of scapular dyskinesis. This review identified a lack of high-quality studies evaluating intra- as well as interrater reliability of tests used for the assessment of scapular dyskinesis. In addition, reliability measures differed between included studies hindering proper cross-study comparisons. The effect of manual correction of the scapula on shoulder symptoms was evaluated in only one study, which is striking, since symptom alteration tests are used in routine care to guide further treatment. Thus, there is a strong need for further research in this area. Diagnosis, level 3a. Copyright © 2016. Published by Elsevier Ltd.

  3. Comparing Interrater reliability between eye examination and eye self-examination 1

    PubMed Central

    de Lima, Maria Alzete; Pagliuca, Lorita Marlena Freitag; do Nascimento, Jennara Cândido; Caetano, Joselany Áfio

    2017-01-01

    Resume Objective: to compare Interrater reliability concerning two eye assessment methods. Method: quasi-experimental study conducted with 324 college students including eye self-examination and eye assessment performed by the researchers in a public university. Kappa coefficient was used to verify agreement. Results: reliability coefficients between Interraters ranged from 0.85 to 0.95, with statistical significance at 0.05. The exams to check for near acuity and peripheral vision presented a reasonable kappa >0.2. The remaining coefficients were higher, ranging from very to totally reliable. Conclusion: comparatively, the results of both methods were similar. The virtual manual on eye self-examination can be used to screen for eye conditions. PMID:29069269

  4. Confirmation of the Basic Psychological Needs in Exercise Scale (BPNES) With a Sample of People who do Healthy Exercise

    PubMed Central

    Moreno-Murcia, Juan A; Martínez-Galindo, Celestina; Moreno-Pérez, Víctor; Marcos, Pablo J.; Borges, Fernanda

    2012-01-01

    This study aimed to cross-validate the psychometric properties of the Basic Psychological Needs in Exercise Scale (BPNES) by Vlachopoulos and Michailidou, 2006 in a Spanish context. Two studies were conducted. Confirmatory factor analysis results confirmed the hypothesized three-factor solution In addition, we documented evidence of reliability, analysed as internal consistency and temporal stability. Future studies should analyse the scale's validity and reliability with different populations and check their experimental effect. Key pointsThe Basic Psychological Needs in Exercise Scale (BPNES) is valid and reliable for measuring basic psychological needs in healthy physical exercise in the Spanish context.The factor structure of three correlated factors has shown minimal invariance across gender. PMID:24149130

  5. The Female Sexual Function Index (FSFI): linguistic validation of the Italian version.

    PubMed

    Filocamo, Maria Teresa; Serati, Maurizio; Li Marzi, Vincenzo; Costantini, Elisabetta; Milanesi, Martina; Pietropaolo, Amelia; Polledro, Patrizio; Gentile, Barbara; Maruccia, Serena; Fornia, Samanta; Lauri, Irene; Alei, Rosanna; Arcangeli, Paola; Sighinolfi, Maria Chiara; Manassero, Francesca; Andretta, Elena; Palazzetti, Anna; Bertelli, Elena; Del Popolo, Giulio; Villari, Donata

    2014-02-01

    Although several new measurements for female sexual dysfunction (FSD) have recently been developed, the Female Sexual Function Index (FSFI) remains the gold standard for screening and one of the most widely used questionnaires. The Italian translation of the FSFI has been used in several studies conducted in Italy, but a linguistic validation of the Italian version does not exist. The aim of this study was to perform a linguistic validation of the Italian version of the FSFI. A multicenter cross-sectional study conducted in 14 urological and gynecological clinics, uniformly distributed over Italian territory. We performed all steps necessary to determine the reliability and the test-retest reliability of the Italian version of the FSFI. The study population was a convenience sample of 409 Italian women. The reliability of the questionnaire was calculated using Cronbach's alpha, which was considered weak, moderate, or high if its value was found less than 0.6, between 0.6 and 0.8, or equal to or greater than 0.8, respectively. The test-retest reliability was assessed for all women in the sample by calculating Pearson's concordance correlation coefficient for each domain and for the total score, both at baseline and after 15 days (r range between -1.00 to +1.00, where +1.00 indicates the strongest positive association). Cronbach's alpha coefficients for total and domain score were sufficiently high, ranging from 0.92 to 0.97 for the total sample. The test-retest procedure revealed that the concordance correlation coefficient was very high both for FSFI-I total score (Pearson's P = 0.93) and for each domain (Pearson's P always >0.92). For the first time in the literature, our study has produced a validated and reliable Italian version of the FSFI questionnaire. Consequently, the Italian FSFI can be used as a reliable tool for preliminary screening for female sexual dysfunction for Italian women. © 2013 International Society for Sexual Medicine.

  6. Descriptive Model of Generic WAMS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hauer, John F.; DeSteese, John G.

    The Department of Energy’s (DOE) Transmission Reliability Program is supporting the research, deployment, and demonstration of various wide area measurement system (WAMS) technologies to enhance the reliability of the Nation’s electrical power grid. Pacific Northwest National Laboratory (PNNL) was tasked by the DOE National SCADA Test Bed Program to conduct a study of WAMS security. This report represents achievement of the milestone to develop a generic WAMS model description that will provide a basis for the security analysis planned in the next phase of this study.

  7. Psychometric evaluation of dietary habits questionnaire for type 2 diabetes mellitus

    NASA Astrophysics Data System (ADS)

    Sami, W.; Ansari, T.; Butt, N. S.; Hamid, M. R. Ab

    2017-09-01

    This research evaluated the psychometric properties of English version of dietary habits questionnaires developed for type 2 diabetic patients. There is scarcity of literature about availability of standardized questionnaires for assessing dietary habits of type 2 diabetics in Saudi Arabia. As dietary habits vary from country to country, therefore, this was an attempt to develop questionnaires that can serve as a baseline. Through intensive literature review, four questionnaires were developed / modified and subsequently tested for psychometric properties. Prior to pilot study, a pre-test was conducted to evaluate the face validity and content validity. The pilot study was conducted from 23 October - 22 November, 2016 to evaluate the questionnaires’ reliability and validity. Systematic random sampling technique was used to collect the data from 132 patients by direct investigation method. Questionnaires assessing diabetes mellitus knowledge (0.891), dietary knowledge (0.869), dietary attitude (0.841) and dietary practices (0.874) had good internal consistency reliability. Factor analysis conducted on dietary attitude questionnaire showed a valid 5 factor solution. Directions of loadings were positive and free from factorial complexity. Relying on the data obtained from type 2 diabetics, these questionnaires can be considered as reliable and valid for the assessment of dietary habits in Saudi Arabia and neighbouring Gulf countries population.

  8. [Helping relationship skills in nurses: the validation of a measurement instrument].

    PubMed

    de Melo, Rosa Cândida Carvalho Pereira; Silva, Maria Júlia Paes; Parreira, Pedro Miguel Dinis; Ferreira, Manuela Maria Conceição

    2011-12-01

    Considering the importance of assessing nurses' helping relationship skills, it was necessary to use reliable and context-adapted instruments. Thus, the objective of this study was to assess the psychometric properties of the Helping Relationship Skills Inventory (Inventário de Competências Relacionais de Ajuda, ICRA), by conducting reliability and validity studies to increase the level of confidence or accuracy of the data obtained using this instrument. This quantitative study was conducted on a sample of 690 nurses who worked in six hospitals and eight health centres in Portugal. The results indicate a multidimensional structure of helping relationship skills, divided into four different dimensions (generic, empathetic, communication and contact skills) with a positive correlation between them. Cronbach's alpha for each dimension was higher than .79, showing a good internal consistency of the items within each factor.

  9. [Validity and Reliability of the Korean Version Scale of the Clinical Learning Environment, Supervision and Nurse Teacher Evaluation Scale (CLES+T)].

    PubMed

    Kim, Sun Hee; Yoo, So Yeon; Kim, Yae Young

    2018-02-01

    This study was conducted to evaluate the validity and reliability of the Korean version of the clinical learning environment, supervision and nurse teacher evaluation scale (CLES+T) that measures the clinical learning environment and the conditions associated with supervision and nurse teachers. The English CLES+T was translated into Korean with forward and back translation. Survey data were collected from 434 nursing students who had more than four days of clinical practice in Korean hospitals. Internal consistency reliability and construct validity using confirmatory and exploratory factor analysis were conducted. SPSS 20.0 and AMOS 22.0 programs were used for data analysis. The exploratory factor analysis revealed seven factors for the thirty three-item scale. Confirmatory factor analysis supported good convergent and discriminant validities. The Cronbach's alpha for the overall scale was .94 and for the seven subscales ranged from .78 to .94. The findings suggest that the 33-items Korean CLES+T is an appropriate instrument to measure Korean nursing students'clinical learning environment with good validity and reliability. © 2018 Korean Society of Nursing Science.

  10. Comparison of stigmatizing experiences between Canadian and Korean patients with depression and bipolar disorders.

    PubMed

    Lee, Hyewon; Milev, Roumen; Paik, Jong-Woo

    2015-12-01

    Stigma is one of the key barriers to mental health services, and there have been growing efforts to develop antistigma programs. However, little research has been done on quantifying experiences of stigma and their psychosocial impacts in the perspectives of those who suffer from mental illnesses. It is essential to develop an instrument that quantifies the extent and impact of stigma. Therefore, we conducted a study to conduct a field test on The Inventory of Stigmatizing Experiences and measure the difference in perceived stigma and its psychosocial impacts on Korean and Canadian patients with depression and bipolar disorders. A cross-sectional comparison study was conducted. Data collection took place at a tertiary care hospital located in Seoul, South Korea. Data for the Canadian patient group were retrieved from a previous study conducted by Lazowski et al. In total, 214 Canadian and 51 Korean individuals with depression and bipolar disorder participated. Canadian participants reported significantly higher experience with stigma (P<0.05) and its impact (P<0.05) compared with Korean participants. Both subscales of the inventory (the Stigma Experiences Scale and the Stigma Impact Scale) were highly reliable, with reliability coefficients of 0.81 and 0.93, respectively. In conclusion, there seems to be higher level of stigma and impact in the Canadian population compared with the Korean population. These differences in stigma experience and their impact in different populations suggest the need to develop more tailored antistigma programs. The Inventory of Stigmatizing Experiences is a highly reliable instrument. © 2015 Wiley Publishing Asia Pty Ltd.

  11. Prevalence and Reliability of Phonological, Surface, and Mixed Profiles in Dyslexia: A Review of Studies Conducted in Languages Varying in Orthographic Depth

    ERIC Educational Resources Information Center

    Sprenger-Charolles, Liliane; Siegel, Linda S.; Jimenez, Juan E.; Ziegler, Johannes C.

    2011-01-01

    The influence of orthographic transparency on the prevalence of dyslexia subtypes was examined in a review of multiple-case studies conducted in languages differing in orthographic depth (English, French, and Spanish). Cross-language differences are found in the proportion of dissociated profiles as a function of the dependent variables (speed or…

  12. DESIGN INFORMATION ON FINE PORE AERATION SYSTEMS

    EPA Science Inventory

    Field studies were conducted over several years at municipal wastewater treatment plants employing line pore diffused aeration systems. These studies were designed to produce reliable information on the performance and operational requirements of fine pore devices under process ...

  13. Predicting students' perceptions of academic misconduct on the Hogan Personality Inventory Reliability Scale.

    PubMed

    Stone, Thomas H; Kisamore, Jennifer L; Jawahar, I M

    2008-04-01

    Interest and research on academic misconduct has become more salient in part due to recent publicized academic and organizational scandals. The current study investigated a possible interaction between perception of the university's academic culture and personality, conceptualized as Reliability, on students' perceptions of academic misconduct. A convenience sample of 217 university business students (91 men, 126 women), whose average age was 22.3 yr. (SD = 4.4) was tested. Reliability was measured with an occupational scale included in the Hogan Personality Inventory. Two hierarchical regression analyses were conducted using Cheating Intentions and Likelihood of Reporting Cheating as criteria. Age, Reliability, Integrity Culture, and the interaction between scores on Reliability and Integrity Culture were entered as predictors. Only Age and Reliability scores were significant predictors of Cheating Intentions, while all variables were significant predictors for Likelihood of Reporting Cheating. Suggestions for practice and research are provided.

  14. Do intensity ratings and skin conductance responses reliably discriminate between different stimulus intensities in experimentally induced pain?

    PubMed

    Breimhorst, Markus; Sandrock, Stephan; Fechir, Marcel; Hausenblas, Nadine; Geber, Christian; Birklein, Frank

    2011-01-01

    The present study addresses the question whether pain-intensity ratings and skin conductance responses (SCRs) are able to detect different intensities of phasic painful stimuli and to determine the reliability of this discrimination. For this purpose, 42 healthy participants of both genders were assigned to either electrical, mechanical, or laser heat-pain stimulation (each n = 14). A whole range of single brief painful stimuli were delivered on the right volar forearm of the dominant hand in a randomized order. Pain-intensity ratings and SCRs were analyzed. Using generalizability theory, individual and gender differences were the main contributors to the variability of both intensity ratings and SCRs. Most importantly, we showed that pain-intensity ratings are a reliable measure for the discrimination of different pain stimulus intensities in the applied modalities. The reliability of SCR was adequate when mechanical and heat stimuli were tested but failed for the discrimination of electrical stimuli. Further studies are needed to reveal the reason for this lack of accuracy for SCRs when applying electrical pain stimuli. Our study could help researchers to better understand the relationship between pain and activation of the sympathetic nervous system. Pain researchers are furthermore encouraged to consider individual and gender differences when measuring pain intensity and the concomitant SCRs in experimental settings. Copyright © 2011 American Pain Society. Published by Elsevier Inc. All rights reserved.

  15. Reliability analysis of hydrologic containment of liquefied petroleum gas within unlined rock caverns.

    NASA Astrophysics Data System (ADS)

    Gao, X.; Yan, E. C.; Yeh, T. C. J.; Wang, Y.; Liang, Y.; Hao, Y.

    2017-12-01

    Notice that most of the underground liquefied petroleum gas (LPG) storage caverns are constructed in unlined rock caverns (URCs), where the variability of hydraulic properties (in particular, hydraulic conductivity) has significant impacts on hydrologic containment performance. However, it is practically impossible to characterize the spatial distribution of these properties in detail at the site of URCs. This dilemma forces us to cope with uncertainty in our evaluations of gas containment. As a consequence, the uncertainty-based analysis is deemed more appropriate than the traditional deterministic analysis. The objectives of this paper are 1) to introduce a numerical first order method to calculate the gas containment reliability within a heterogeneous, two-dimensional unlined rock caverns, and 2) to suggest a strategy for improving the gas containment reliability. In order to achieve these goals, we first introduced the stochastic continuum representation of saturated hydraulic conductivity (Ks) of fractured rock and analyzed the spatial variability of Ks at a field site. We then conducted deterministic simulations to demonstrate the importance of heterogeneity of Ks in the analysis of gas tightness performance of URCs. Considering the uncertainty of the heterogeneity in the real world situations, we subsequently developed a numerical first order method (NFOM) to determine the gas tightness reliability at crucial locations of URCs. Using the NFOM, the effect of spatial variability of Ks on gas tightness reliability was investigated. Results show that as variance or spatial structure anisotropy of Ks increases, most of the gas tightness reliability at crucial locations reduces. Meanwhile, we compare the results of NFOM with those of Monte Carlo simulation, and we find the accuracy of NFOM is mainly affected by the magnitude of the variance of Ks. At last, for improving gas containment reliability at crucial locations at this study site, we suggest that vertical water-curtain holes should be installed in the pillar rather than increasing density of horizontal water-curtain boreholes.

  16. Experimental Study of Solder/Copper Interface Failure Under Varying Strain Rates

    DTIC Science & Technology

    2011-03-01

    Factors Affecting Solder Joint Reliability Gu et al. [1] determined that during the life cycle of electronic assemblies, approximately 55 percent of...related to vibration and shock, with the remaining percentage associated with changes in 2 humidity. Research conducted by Ross et al. [2] adds...that creep strain is the most important time-dependent factor affecting the reliability of solder joints in electronic equipment. 2. Effects of

  17. Assessing the reliability of ecotoxicological studies: An overview of current needs and approaches.

    PubMed

    Moermond, Caroline; Beasley, Amy; Breton, Roger; Junghans, Marion; Laskowski, Ryszard; Solomon, Keith; Zahner, Holly

    2017-07-01

    In general, reliable studies are well designed and well performed, and enough details on study design and performance are reported to assess the study. For hazard and risk assessment in various legal frameworks, many different types of ecotoxicity studies need to be evaluated for reliability. These studies vary in study design, methodology, quality, and level of detail reported (e.g., reviews, peer-reviewed research papers, or industry-sponsored studies documented under Good Laboratory Practice [GLP] guidelines). Regulators have the responsibility to make sound and verifiable decisions and should evaluate each study for reliability in accordance with scientific principles regardless of whether they were conducted in accordance with GLP and/or standardized methods. Thus, a systematic and transparent approach is needed to evaluate studies for reliability. In this paper, 8 different methods for reliability assessment were compared using a number of attributes: categorical versus numerical scoring methods, use of exclusion and critical criteria, weighting of criteria, whether methods are tested with case studies, domain of applicability, bias toward GLP studies, incorporation of standard guidelines in the evaluation method, number of criteria used, type of criteria considered, and availability of guidance material. Finally, some considerations are given on how to choose a suitable method for assessing reliability of ecotoxicity studies. Integr Environ Assess Manag 2017;13:640-651. © 2016 The Authors. Integrated Environmental Assessment and Management published by Wiley Periodicals, Inc. on behalf of Society of Environmental Toxicology & Chemistry (SETAC). © 2016 The Authors. Integrated Environmental Assessment and Management published by Wiley Periodicals, Inc. on behalf of Society of Environmental Toxicology & Chemistry (SETAC).

  18. 'I don't have to go to the gym because I ate very healthy today': the development of a scale to assess diet-related compensatory health beliefs.

    PubMed

    Poelman, Maartje P; Vermeer, Willemijn M; Vyth, Ellis L; Steenhuis, Ingrid H M

    2013-02-01

    Nutritional interventions to decrease energy intake, aimed at portion sizes and front-of-package labelling, are effective only if people do not compensate for their reduced energy intake. Since several observational studies indicate that these interventions could prompt compensation behaviour, it is important to assess underlying beliefs. Therefore, the purpose of the two studies reported here was to develop a Diet-related Compensatory Health Beliefs Scale (Diet-CHBS). Cross-sectional surveys were conducted for the scale development. Study 1 provided data on the factor analysis and convergent validity, while Study 2 assessed the Diet-CHBS' test-retest reliability. Settings VU University Amsterdam (Study 1) and twenty-five worksite cafeterias in the Netherlands (Study 2). Study 1 was conducted among 179 students and their parents; Study 2 was conducted among 119 worksite cafeteria visitors. The results of Study 1 showed that the scale consisted of the hypothesized factors of compensation beliefs with regard to portion sizes (α = 0·73), front-of-package health logos (α = 0·77) and exercise (α = 0·75). The scale's overall Cronbach's α was 0·82. The Diet-CHBS had a Pearson correlation of 0·32 with a general health compensatory beliefs scale, signifying satisfactory convergent validity. Study 2 showed that the intra-class correlation coefficient between T1 and T2 was 0·69, indicating adequate test-retest reliability. The Diet-CHBS is a valid and reliable instrument for assessing diet-related compensatory health beliefs in response to nutritional interventions. It is important to take such beliefs into account in further intervention studies aimed at preventing overweight and obesity.

  19. Chapter 15: Reliability of Wind Turbines

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sheng, Shuangwen; O'Connor, Ryan

    The global wind industry has witnessed exciting developments in recent years. The future will be even brighter with further reductions in capital and operation and maintenance costs, which can be accomplished with improved turbine reliability, especially when turbines are installed offshore. One opportunity for the industry to improve wind turbine reliability is through the exploration of reliability engineering life data analysis based on readily available data or maintenance records collected at typical wind plants. If adopted and conducted appropriately, these analyses can quickly save operation and maintenance costs in a potentially impactful manner. This chapter discusses wind turbine reliability bymore » highlighting the methodology of reliability engineering life data analysis. It first briefly discusses fundamentals for wind turbine reliability and the current industry status. Then, the reliability engineering method for life analysis, including data collection, model development, and forecasting, is presented in detail and illustrated through two case studies. The chapter concludes with some remarks on potential opportunities to improve wind turbine reliability. An owner and operator's perspective is taken and mechanical components are used to exemplify the potential benefits of reliability engineering analysis to improve wind turbine reliability and availability.« less

  20. Reducing random measurement error in assessing postural load on the back in epidemiologic surveys.

    PubMed

    Burdorf, A

    1995-02-01

    The goal of this study was to design strategies to assess postural load on the back in occupational epidemiology by taking into account the reliability of measurement methods and the variability of exposure among the workers under study. Intermethod reliability studies were evaluated to estimate the systematic bias (accuracy) and random measurement error (precision) of various methods to assess postural load on the back. Intramethod reliability studies were reviewed to estimate random variability of back load over time. Intermethod surveys have shown that questionnaires have a moderate reliability for gross activities such as sitting, whereas duration of trunk flexion and rotation should be assessed by observation methods or inclinometers. Intramethod surveys indicate that exposure variability can markedly affect the reliability of estimates of back load if the estimates are based upon a single measurement over a certain time period. Equations have been presented to evaluate various study designs according to the reliability of the measurement method, the optimum allocation of the number of repeated measurements per subject, and the number of subjects in the study. Prior to a large epidemiologic study, an exposure-oriented survey should be conducted to evaluate the performance of measurement instruments and to estimate sources of variability for back load. The strategy for assessing back load can be optimized by balancing the number of workers under study and the number of repeated measurements per worker.

  1. Evaluating the validity and reliability of the V-scale instrument (Turkish version) used to determine nurses' attitudes towards vital sign monitoring.

    PubMed

    Ertuğ, Nurcan

    2018-06-01

    The aim of this study was to determine the validity and reliability of the Turkish version of the V-scale, which measures nurses' attitudes towards vital signs monitoring in the detection of clinical deterioration. This validity and reliability study was conducted at a tertiary hospital in Ankara, Turkey, in 2016. A total of 169 ward nurses participated in the study. Exploratory factor analysis, Cronbach's alpha coefficient, and the intraclass correlation coefficient were used to determine the validity and reliability of the scale. A 5-factor, 16-item scale explained 60.823% of the total variance according to the validity analysis. Our version matched the original scale in terms of the number of items and factor structure. Cronbach's alpha coefficient of the Turkish version of the V-scale was 0.764. The test-retest reliability results were 0.855 for the overall intraclass correlation coefficient, and the t-test result was P > 0.05. The V-scale is a reliable and valid instrument to measure Turkish nurses' attitudes towards vital signs monitoring in the detection of clinical deterioration. © 2018 John Wiley & Sons Australia, Ltd.

  2. On the Simulation-Based Reliability of Complex Emergency Logistics Networks in Post-Accident Rescues.

    PubMed

    Wang, Wei; Huang, Li; Liang, Xuedong

    2018-01-06

    This paper investigates the reliability of complex emergency logistics networks, as reliability is crucial to reducing environmental and public health losses in post-accident emergency rescues. Such networks' statistical characteristics are analyzed first. After the connected reliability and evaluation indices for complex emergency logistics networks are effectively defined, simulation analyses of network reliability are conducted under two different attack modes using a particular emergency logistics network as an example. The simulation analyses obtain the varying trends in emergency supply times and the ratio of effective nodes and validates the effects of network characteristics and different types of attacks on network reliability. The results demonstrate that this emergency logistics network is both a small-world and a scale-free network. When facing random attacks, the emergency logistics network steadily changes, whereas it is very fragile when facing selective attacks. Therefore, special attention should be paid to the protection of supply nodes and nodes with high connectivity. The simulation method provides a new tool for studying emergency logistics networks and a reference for similar studies.

  3. On the Simulation-Based Reliability of Complex Emergency Logistics Networks in Post-Accident Rescues

    PubMed Central

    Wang, Wei; Huang, Li; Liang, Xuedong

    2018-01-01

    This paper investigates the reliability of complex emergency logistics networks, as reliability is crucial to reducing environmental and public health losses in post-accident emergency rescues. Such networks’ statistical characteristics are analyzed first. After the connected reliability and evaluation indices for complex emergency logistics networks are effectively defined, simulation analyses of network reliability are conducted under two different attack modes using a particular emergency logistics network as an example. The simulation analyses obtain the varying trends in emergency supply times and the ratio of effective nodes and validates the effects of network characteristics and different types of attacks on network reliability. The results demonstrate that this emergency logistics network is both a small-world and a scale-free network. When facing random attacks, the emergency logistics network steadily changes, whereas it is very fragile when facing selective attacks. Therefore, special attention should be paid to the protection of supply nodes and nodes with high connectivity. The simulation method provides a new tool for studying emergency logistics networks and a reference for similar studies. PMID:29316614

  4. Issues in benchmarking human reliability analysis methods : a literature review.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lois, Erasmia; Forester, John Alan; Tran, Tuan Q.

    There is a diversity of human reliability analysis (HRA) methods available for use in assessing human performance within probabilistic risk assessment (PRA). Due to the significant differences in the methods, including the scope, approach, and underlying models, there is a need for an empirical comparison investigating the validity and reliability of the methods. To accomplish this empirical comparison, a benchmarking study is currently underway that compares HRA methods with each other and against operator performance in simulator studies. In order to account for as many effects as possible in the construction of this benchmarking study, a literature review was conducted,more » reviewing past benchmarking studies in the areas of psychology and risk assessment. A number of lessons learned through these studies are presented in order to aid in the design of future HRA benchmarking endeavors.« less

  5. Discrete component bonding and thick film materials study

    NASA Technical Reports Server (NTRS)

    Kinser, D. L.

    1975-01-01

    The results are summarized of an investigation of discrete component bonding reliability and a fundamental study of new thick film resistor materials. The component bonding study examined several types of solder bonded components with some processing variable studies to determine their influence upon bonding reliability. The bonding reliability was assessed using the thermal cycle: 15 minutes at room temperature, 15 minutes at +125 C 15 minutes at room temperature, and 15 minutes at -55 C. The thick film resistor materials examined were of the transition metal oxide-phosphate glass family with several elemental metal additions of the same transition metal. These studies were conducted by preparing a paste of the subject composition, printing, drying, and firing using both air and reducing atmospheres. The resulting resistors were examined for adherence, resistance, thermal coefficient of resistance, and voltage coefficient of resistance.

  6. Reliability and Validity of Prototype Diagnosis for Adolescent Psychopathology.

    PubMed

    Haggerty, Greg; Zodan, Jennifer; Mehra, Ashwin; Zubair, Ayyan; Ghosh, Krishnendu; Siefert, Caleb J; Sinclair, Samuel J; DeFife, Jared

    2016-04-01

    The current study investigated the interrater reliability and validity of prototype ratings of 5 common adolescent psychiatric disorders: attention-deficit/hyperactivity disorder, conduct disorder, major depressive disorder, generalized anxiety disorder, and posttraumatic stress disorder. One hundred fifty-seven adolescent inpatient participants consented to participate in this study. We compared ratings from 2 inpatient clinicians, blinded to each other's ratings and patient measures, after their separate initial diagnostic interview to assess interrater reliability. Prototype ratings completed by clinicians after their initial diagnostic interview with adolescent inpatients and outpatients were compared with patient-reported behavior problems and parents' report of their child's behavioral problems. Prototype ratings demonstrated good interrater reliability. Clinicians' prototype ratings showed predicted relationships with patient-reported behavior problems and parent-reported behavior problems. Prototype matching seems to be a possible alternative for psychiatric diagnosis. Prototype ratings showed good interrater reliability based on clinicians unique experiences with the patient (as opposed to video-/audio-recorded material) with no training.

  7. Principle of maximum entropy for reliability analysis in the design of machine components

    NASA Astrophysics Data System (ADS)

    Zhang, Yimin

    2018-03-01

    We studied the reliability of machine components with parameters that follow an arbitrary statistical distribution using the principle of maximum entropy (PME). We used PME to select the statistical distribution that best fits the available information. We also established a probability density function (PDF) and a failure probability model for the parameters of mechanical components using the concept of entropy and the PME. We obtained the first four moments of the state function for reliability analysis and design. Furthermore, we attained an estimate of the PDF with the fewest human bias factors using the PME. This function was used to calculate the reliability of the machine components, including a connecting rod, a vehicle half-shaft, a front axle, a rear axle housing, and a leaf spring, which have parameters that typically follow a non-normal distribution. Simulations were conducted for comparison. This study provides a design methodology for the reliability of mechanical components for practical engineering projects.

  8. Integrating reliability and maintainability into a concurrent engineering environment

    NASA Astrophysics Data System (ADS)

    Phillips, Clifton B.; Peterson, Robert R.

    1993-02-01

    This paper describes the results of a reliability and maintainability study conducted at the University of California, San Diego and supported by private industry. Private industry thought the study was important and provided the university access to innovative tools under cooperative agreement. The current capability of reliability and maintainability tools and how they fit into the design process is investigated. The evolution of design methodologies leading up to today's capability is reviewed for ways to enhance the design process while keeping cost under control. A method for measuring the consequences of reliability and maintainability policy for design configurations in an electronic environment is provided. The interaction of selected modern computer tool sets is described for reliability, maintainability, operations, and other elements of the engineering design process. These tools provide a robust system evaluation capability that brings life cycle performance improvement information to engineers and their managers before systems are deployed, and allow them to monitor and track performance while it is in operation.

  9. Translation and validation of the Malay version of the Stroke Knowledge Test.

    PubMed

    Sowtali, Siti Noorkhairina; Yusoff, Dariah Mohd; Harith, Sakinah; Mohamed, Monniaty

    2016-04-01

    To date, there is a lack of published studies on assessment tools to evaluate the effectiveness of stroke education programs. This study developed and validated the Malay language version of the Stroke Knowledge Test research instrument. This study involved translation, validity, and reliability phases. The instrument underwent backward and forward translation of the English version into the Malay language. Nine experts reviewed the content for consistency, clarity, difficulty, and suitability for inclusion. Perceived usefulness and utilization were obtained from experts' opinions. Later, face validity assessment was conducted with 10 stroke patients to determine appropriateness of sentences and grammar used. A pilot study was conducted with 41 stroke patients to determine the item analysis and reliability of the translated instrument using the Kuder Richardson 20 or Cronbach's alpha. The final Malay version Stroke Knowledge Test included 20 items with good content coverage, acceptable item properties, and positive expert review ratings. Psychometric investigations suggest that Malay version Stroke Knowledge Test had moderate reliability with Kuder Richardson 20 or Cronbach's alpha of 0.58. Improvement is required for Stroke Knowledge Test items with unacceptable difficulty indices. Overall, the average rating of perceived usefulness and perceived utility of the instruments were both 72.7%, suggesting that reviewers were likely to use the instruments in their facilities. Malay version Stroke Knowledge Test was a valid and reliable tool to assess educational needs and to evaluate stroke knowledge among participants of group-based stroke education programs in Malaysia.

  10. Otoplasty Online Information: A Comprehensive Analysis of the Websites and Videos that Patients View Regarding Cosmetic Ear Surgery.

    PubMed

    Nissan, Michael E; Gupta, Amar; Rayess, Hani; Black, Kevin Z; Carron, Michael

    2018-02-01

    Physicians should be aware of both websites and videos available online regarding the otoplasty procedure to provide quality care. This study systematically analyzes the authorships, reliability, quality, and readability of the websites, as well as the authorships and primary objectives of the videos regarding otoplasty. Validated instruments were used to analyze the reliability, quality, and readability of websites, and videos were systematically categorized and analyzed. A Google search was conducted, and the first five pages of results were included in this study. After excluding unrelated websites, the remaining 44 websites were categorized by authorship (physician, patient, academic, or unaffiliated) and were analyzed using the validated DISCERN instrument for reliability and quality, as well as various other validated instruments to measure readability. A YouTube search was also conducted, and the first 50 relevant videos were included in the study. These videos were categorized by authorship and their primary objective. Website authorships were physician-dominated. Reliability, quality, and overall DISCERN score differ between the four authorship groups by a statistically significant margin (Kruskall-Wallis test, p  < 0.05). Unaffiliated websites were the most reliable, and physician websites were the least reliable. Academic websites were of the highest quality, and patient websites were of the lowest quality. Readability did not differ significantly between the groups, though the readability measurements made showed a general lack of material easily readable by the general public. YouTube was likewise dominated by physician-authored videos. While the physician-authored videos sought mainly to inform and to advertise, patient-authored videos sought mainly to provide the patient's perspective. Academic organizations showed very little representation on YouTube, and the YouTube views on otoplasty videos were dominated by the top 20 videos, which represented over 93% of the total views of videos included in this study. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  11. Reliability of diagnosis and clinical efficacy of visceral osteopathy: a systematic review.

    PubMed

    Guillaud, Albin; Darbois, Nelly; Monvoisin, Richard; Pinsault, Nicolas

    2018-02-17

    In 2010, the World Health Organization published benchmarks for training in osteopathy in which osteopathic visceral techniques are included. The purpose of this study was to identify and critically appraise the scientific literature concerning the reliability of diagnosis and the clinical efficacy of techniques used in visceral osteopathy. Databases MEDLINE, OSTMED.DR, the Cochrane Library, Osteopathic Research Web, Google Scholar, Journal of American Osteopathic Association (JAOA) website, International Journal of Osteopathic Medicine (IJOM) website, and the catalog of Académie d'ostéopathie de France website were searched through December 2017. Only inter-rater reliability studies including at least two raters or the intra-rater reliability studies including at least two assessments by the same rater were included. For efficacy studies, only randomized-controlled-trials (RCT) or crossover studies on unhealthy subjects (any condition, duration and outcome) were included. Risk of bias was determined using a modified version of the quality appraisal tool for studies of diagnostic reliability (QAREL) in reliability studies. For the efficacy studies, the Cochrane risk of bias tool was used to assess their methodological design. Two authors performed data extraction and analysis. Eight reliability studies and six efficacy studies were included. The analysis of reliability studies shows that the diagnostic techniques used in visceral osteopathy are unreliable. Regarding efficacy studies, the least biased study shows no significant difference for the main outcome. The main risks of bias found in the included studies were due to the absence of blinding of the examiners, an unsuitable statistical method or an absence of primary study outcome. The results of the systematic review lead us to conclude that well-conducted and sound evidence on the reliability and the efficacy of techniques in visceral osteopathy is absent. The review is registered PROSPERO 12th of December 2016. Registration number is CRD4201605286 .

  12. Psychometric instrumentation: reliability and validity of instruments used for clinical practice, evidence-based practice projects and research studies.

    PubMed

    Mayo, Ann M

    2015-01-01

    It is important for CNSs and other APNs to consider the reliability and validity of instruments chosen for clinical practice, evidence-based practice projects, or research studies. Psychometric testing uses specific research methods to evaluate the amount of error associated with any particular instrument. Reliability estimates explain more about how well the instrument is designed, whereas validity estimates explain more about scores that are produced by the instrument. An instrument may be architecturally sound overall (reliable), but the same instrument may not be valid. For example, if a specific group does not understand certain well-constructed items, then the instrument does not produce valid scores when used with that group. Many instrument developers may conduct reliability testing only once, yet continue validity testing in different populations over many years. All CNSs should be advocating for the use of reliable instruments that produce valid results. Clinical nurse specialists may find themselves in situations where reliability and validity estimates for some instruments that are being utilized are unknown. In such cases, CNSs should engage key stakeholders to sponsor nursing researchers to pursue this most important work.

  13. A Preliminary Study on the Reliability of the Malay Version of PedsQL™ Family Impact Module among Caregivers of Children with Disabilities in Kelantan, Malaysia

    PubMed Central

    Rahman, Azriani Ab; Mohamad, Norsarwany; Imran, Musa Kamarul; Ibrahim, Wan Pauzi Wan; Othman, Azizah; Aziz, Aniza Abd; Harith, Sakinah; Ibrahim, Mohd Ismail; Ariffin, Nor Hashimah; Van Rostenberghe, Hans

    2011-01-01

    Background: No previous study has assessed the impact of childhood disability on parents and family in the context of Malaysia, and no instrument to measure this impact has previously been available. The objective of this cross-sectional study was to determine the reliability of a Malay version of the PedsQL™ Family Impact Module that measures the impact of children with disabilities (CWD) on their parents and family in a Malaysian context. Methods: The study was conducted in 2009. The questionnaire was translated forward and backward before it was administered to 44 caregivers of CWD to determine the internal consistency reliability. The test for Cronbach’s alpha was performed. Results: The internal consistency reliability was good. The Cronbach’s alpha for all domains was above 0.7, ranging from 0.73 to 0.895. Conclusion: The Malay version of the PedsQL™ Family Impact Module showed evidence of good internal consistency reliability. However, future studies with a larger sample size are necessary before the module can be recommended as a tool to measure the impact of disability on Malay-speaking Malaysian families. PMID:22589674

  14. 18 CFR 39.11 - Reliability reports.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... Electric Reliability Organization shall conduct assessments of the adequacy of the Bulk-Power System in... assessments as determined by the Commission of the reliability of the Bulk-Power System in North America and... 18 Conservation of Power and Water Resources 1 2010-04-01 2010-04-01 false Reliability reports. 39...

  15. A Turkish version of myocardial infarction dimensional assessment scale (TR-MIDAS): reliability-validity assesment.

    PubMed

    Uysal, Hilal; Ozcan, Şeyda

    2011-06-01

    Many new measuring devices have been developed so that broader psychometric measurements in the coronary artery disease, disease-specific health status measurements, and identification of the broader quality of life can be performed in the recent years. The study was intended to determine whether, and to what extent, MIDAS is a valid and reliable measurement to the patients suffering from myocardial infarction for the first time in Turkey. The research was conducted with the patients hospitalized and treated with myocardial infarction in the cardiology departments of 2 hospitals in Istanbul, Turkey, between 2007 and 2008. Psychometric evaluations of TR-MIDAS were used for validity studies; language validity, content validity, construct validity were examined. For reliability studies; the tool's internal consistency reliability, Cronbach's alpha reliability coefficient, and test-retest reliability were completed. The instrument's content validity index was determined to be "0.95". Principal component analysis revealed six factors with an eigenvalue >1.5. Cronbach's alpha was found to be 0.89 for total scale which was an acceptable value. The total's test-retest reliability was 0.51 (p<0.01). Data obtained at the end of the study supports that Turkish Myocardial Infarction Dimensional Assessment Scale is a valid and reliable instrument as a disease-specific scale to assess the patients' quality of life suffering from myocardial infarction in Turkey. Copyright © 2010 European Society of Cardiology. Published by Elsevier B.V. All rights reserved.

  16. Live versus Video Observations: Comparing the Reliability and Validity of Two Methods of Assessing Classroom Quality

    ERIC Educational Resources Information Center

    Curby, Timothy W.; Johnson, Price; Mashburn, Andrew J.; Carlis, Lydia

    2016-01-01

    When conducting classroom observations, researchers are often confronted with the decision of whether to conduct observations live or by using pre-recorded video. The present study focuses on comparing and contrasting observations of live and video administrations of the Classroom Assessment Scoring System-PreK (CLASS-PreK). Associations between…

  17. Study of solid rocket motors for a space shuttle booster. Volume 3: Program acquisition planning

    NASA Technical Reports Server (NTRS)

    Vonderesch, A. H.

    1972-01-01

    Plans for conducting Phase C/D for a solid rocket motor booster vehicle are presented. Methods for conducting this program with details of scheduling, testing, and program management and control are included. The requirements of the space shuttle program to deliver a minimum cost/maximum reliability booster vehicle are examined.

  18. Reliability Evaluation of Next Generation Inverter: Cooperative Research and Development Final Report, CRADA Number CRD-12-478

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Paret, Paul

    The National Renewable Energy Laboratory (NREL) will conduct thermal and reliability modeling on three sets of power modules for the development of a next generation inverter for electric traction drive vehicles. These modules will be chosen by General Motors (GM) to represent three distinct technological approaches to inverter power module packaging. Likely failure mechanisms will be identified in each package and a physics-of-failure-based reliability assessment will be conducted.

  19. TCOPPE school environmental audit tool: assessing safety and walkability of school environments.

    PubMed

    Lee, Chanam; Kim, Hyung Jin; Dowdy, Diane M; Hoelscher, Deanna M; Ory, Marcia G

    2013-09-01

    Several environmental audit instruments have been developed for assessing streets, parks and trails, but none for schools. This paper introduces a school audit tool that includes 3 subcomponents: 1) street audit, 2) school site audit, and 3) map audit. It presents the conceptual basis and the development process of this instrument, and the methods and results of the reliability assessments. Reliability tests were conducted by 2 trained auditors on 12 study schools (high-low income and urban-suburban-rural settings). Kappa statistics (categorical, factual items) and ICC (Likert-scale, perceptual items) were used to assess a) interrater, b) test-retest, and c) peak vs. off-peak hour reliability tests. For the interrater reliability test, the average Kappa was 0.839 and the ICC was 0.602. For the test-retest reliability, the average Kappa was 0.903 and the ICC was 0.774. The peak-off peak reliability was 0.801. Rural schools showed the most consistent results in the peak-off peak and test-retest assessments. For interrater tests, urban schools showed the highest ICC, and rural schools showed the highest Kappa. Most items achieved moderate to high levels of reliabilities in all study schools. With proper training, this audit can be used to assess school environments reliably for research, outreach, and policy-support purposes.

  20. Reliability and minimal detectable difference in multisegment foot kinematics during shod walking and running.

    PubMed

    Milner, Clare E; Brindle, Richard A

    2016-01-01

    There has been increased interest recently in measuring kinematics within the foot during gait. While several multisegment foot models have appeared in the literature, the Oxford foot model has been used frequently for both walking and running. Several studies have reported the reliability for the Oxford foot model, but most studies to date have reported reliability for barefoot walking. The purpose of this study was to determine between-day (intra-rater) and within-session (inter-trial) reliability of the modified Oxford foot model during shod walking and running and calculate minimum detectable difference for common variables of interest. Healthy adult male runners participated. Participants ran and walked in the gait laboratory for five trials of each. Three-dimensional gait analysis was conducted and foot and ankle joint angle time series data were calculated. Participants returned for a second gait analysis at least 5 days later. Intraclass correlation coefficients and minimum detectable difference were determined for walking and for running, to indicate both within-session and between-day reliability. Overall, relative variables were more reliable than absolute variables, and within-session reliability was greater than between-day reliability. Between-day intraclass correlation coefficients were comparable to those reported previously for adults walking barefoot. It is an extension in the use of the Oxford foot model to incorporate wearing a shoe while maintaining marker placement directly on the skin for each segment. These reliability data for walking and running will aid in the determination of meaningful differences in studies which use this model during shod gait. Copyright © 2015 Elsevier B.V. All rights reserved.

  1. The Japanese version of the questionnaire about the process of recovery: development and validity and reliability testing.

    PubMed

    Kanehara, Akiko; Kotake, Risa; Miyamoto, Yuki; Kumakura, Yousuke; Morita, Kentaro; Ishiura, Tomoko; Shimizu, Kimiko; Fujieda, Yumiko; Ando, Shuntaro; Kondo, Shinsuke; Kasai, Kiyoto

    2017-11-07

    Personal recovery is increasingly recognised as an important outcome measure in mental health services. This study aimed to develop a Japanese version of the Questionnaire about the Process of Recovery (QPR-J) and test its validity and reliability. The study comprised two stages that employed the cross-sectional and prospective cohort designs, respectively. We translated the questionnaire using a standard translation/back-translation method. Convergent validity was examined by calculating Pearson's correlation coefficients with scores on the Recovery Assessment Scale (RAS) and the Short-Form-8 Health Survey (SF-8). An exploratory factor analysis (EFA) was conducted to examine factorial validity. We used intraclass correlation and Cronbach's alpha to examine the test-retest and internal consistency reliability of the QPR-J's 22-item full scale, 17-item intrapersonal and 5-item interpersonal subscales. We conducted an EFA along with a confirmatory factor analysis (CFA). Data were obtained from 197 users of mental health services (mean age: 42.0 years; 61.9% female; 49.2% diagnosed with schizophrenia). The QPR-J showed adequate convergent validity, exhibiting significant, positive correlations with the RAS and SF-8 scores. The QPR-J's full version, subscales, showed excellent test-retest and internal consistency reliability, with the exception of acceptable but relatively low internal consistency reliability for the interpersonal subscale. Based on the results of the CFA and EFA, we adopted the factor structure extracted from the original 2-factor model based on the present CFA. The QPR-J is an adequately valid and reliable measure of the process of recovery among Japanese users with mental health services.

  2. System reliability of randomly vibrating structures: Computational modeling and laboratory testing

    NASA Astrophysics Data System (ADS)

    Sundar, V. S.; Ammanagi, S.; Manohar, C. S.

    2015-09-01

    The problem of determination of system reliability of randomly vibrating structures arises in many application areas of engineering. We discuss in this paper approaches based on Monte Carlo simulations and laboratory testing to tackle problems of time variant system reliability estimation. The strategy we adopt is based on the application of Girsanov's transformation to the governing stochastic differential equations which enables estimation of probability of failure with significantly reduced number of samples than what is needed in a direct simulation study. Notably, we show that the ideas from Girsanov's transformation based Monte Carlo simulations can be extended to conduct laboratory testing to assess system reliability of engineering structures with reduced number of samples and hence with reduced testing times. Illustrative examples include computational studies on a 10-degree of freedom nonlinear system model and laboratory/computational investigations on road load response of an automotive system tested on a four-post test rig.

  3. Issues in Benchmarking Human Reliability Analysis Methods: A Literature Review

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ronald L. Boring; Stacey M. L. Hendrickson; John A. Forester

    There is a diversity of human reliability analysis (HRA) methods available for use in assessing human performance within probabilistic risk assessments (PRA). Due to the significant differences in the methods, including the scope, approach, and underlying models, there is a need for an empirical comparison investigating the validity and reliability of the methods. To accomplish this empirical comparison, a benchmarking study comparing and evaluating HRA methods in assessing operator performance in simulator experiments is currently underway. In order to account for as many effects as possible in the construction of this benchmarking study, a literature review was conducted, reviewing pastmore » benchmarking studies in the areas of psychology and risk assessment. A number of lessons learned through these studies are presented in order to aid in the design of future HRA benchmarking endeavors.« less

  4. An In vitro evaluation of the reliability of QR code denture labeling technique.

    PubMed

    Poovannan, Sindhu; Jain, Ashish R; Krishnan, Cakku Jalliah Venkata; Chandran, Chitraa R

    2016-01-01

    Positive identification of the dead after accidents and disasters through labeled dentures plays a key role in forensic scenario. A number of denture labeling methods are available, and studies evaluating their reliability under drastic conditions are vital. This study was conducted to evaluate the reliability of QR (Quick Response) Code labeled at various depths in heat-cured acrylic blocks after acid treatment, heat treatment (burns), and fracture in forensics. It was an in vitro study. This study included 160 specimens of heat-cured acrylic blocks (1.8 cm × 1.8 cm) and these were divided into 4 groups (40 samples per group). QR Codes were incorporated in the samples using clear acrylic sheet and they were assessed for reliability under various depths, acid, heat, and fracture. Data were analyzed using Chi-square test, test of proportion. The QR Code inclusion technique was reliable under various depths of acrylic sheet, acid (sulfuric acid 99%, hydrochloric acid 40%) and heat (up to 370°C). Results were variable with fracture of QR Code labeled acrylic blocks. Within the limitations of the study, by analyzing the results, it was clearly indicated that the QR Code technique was reliable under various depths of acrylic sheet, acid, and heat (370°C). Effectiveness varied in fracture and depended on the level of distortion. This study thus suggests that QR Code is an effective and simpler denture labeling method.

  5. Perfluorinated Alkyl Compounds: Challenges To Develop Robust And Reliable Methods

    EPA Science Inventory

    An increasing number of studies have been conducted to investigate the environmental distribution of perfluorinated alkyl compounds (PFCs), some of which are known to be toxic in laboratory studies. Despite growing public concerns, environmental monitoring data are still limited...

  6. Rail-Highway Crossing Resource Allocation Procedure. User's Guide. 2nd edition.

    DOT National Transportation Integrated Search

    2006-01-01

    This report presents findings from a customer satisfaction study conducted in Cobb County, Georgia. The primary hypothesis of this study is that it is possible to develop customer satisfaction measures that are a reliable determinant of roadway quali...

  7. Air Starters for Transit Buses

    DOT National Transportation Integrated Search

    1983-05-01

    This study was conducted to familiarize transit agencies with the potential benefits gained by utilizing air starting systems as an alternative to electrical starting systems. The potential benefits include improved starting reliability under hot and...

  8. Development and Validation of a Safety Climate Scale for Manufacturing Industry

    PubMed Central

    Ghahramani, Abolfazl; Khalkhali, Hamid R.

    2015-01-01

    Background This paper describes the development of a scale for measuring safety climate. Methods This study was conducted in six manufacturing companies in Iran. The scale developed through conducting a literature review about the safety climate and constructing a question pool. The number of items was reduced to 71 after performing a screening process. Results The result of content validity analysis showed that 59 items had excellent item content validity index (≥ 0.78) and content validity ratio (> 0.38). The exploratory factor analysis resulted in eight safety climate dimensions. The reliability value for the final 45-item scale was 0.96. The result of confirmatory factor analysis showed that the safety climate model is satisfactory. Conclusion This study produced a valid and reliable scale for measuring safety climate in manufacturing companies. PMID:26106508

  9. Development, Construct Validity, and Reliability of the Questionnaire on Infant Feeding: A Tool for Measuring Contemporary Infant-Feeding Behaviors.

    PubMed

    O'Sullivan, Elizabeth J; Rasmussen, Kathleen M

    2017-12-01

    The breastfeeding surveillance tool in the United States, the National Immunization Survey, considers the maternal-infant dyad to be breastfeeding for as long as the infant consumes human milk (HM). However, many infants consume at least some HM from a bottle, which can lead to health outcomes different from those for at-the-breast feeding. Our aim was to develop a construct-valid questionnaire that categorizes infants by nutrition source, that is, own mother's HM, another mother's HM, infant formula, or other and feeding mode, that is, at the breast or from a bottle, and test the reliability of this questionnaire. The Questionnaire on Infant Feeding was developed through a literature review and modified based on qualitative research. Construct validity was assessed through cognitive interviews and a test-retest reliability study was conducted among mothers who completed the questionnaire twice, 1 month apart. Cognitive interviews were conducted with ten mothers from upstate New York between September and December 2014. A test-retest reliability study was conducted among 44 mothers from across the United States between March and May 2015. Equivalence of questions with continuous responses about the timing of starting and stopping various behaviors and the agreement between responses to questions with categorical responses on the two questionnaires completed 1 month apart. Reliability was assessed using paired-equivalence tests for questions about the timing of starting and stopping behaviors and weighted Cohen's κ for questions about the frequency and intensity of behaviors. Reliability of the Questionnaire on Infant Feeding was moderately high among mothers of infants aged 19 to 35 months, with most questions about the timing of starting and stopping behaviors equivalent to within 1 month. Weighted Cohen's κ for categorical questions indicated substantial agreement. The Questionnaire on Infant Feeding is a construct-valid tool to measure duration, intensity, and mode of infant HM consumption and duration of maternal HM production that is reliable within 19 to 35 months postpartum. Criterion-validity testing of these questions will improve the utility of the Questionnaire on Infant Feeding as a surveillance tool. Copyright © 2017 Academy of Nutrition and Dietetics. Published by Elsevier Inc. All rights reserved.

  10. Evaluation of the Transit Reliability Information Program

    DOT National Transportation Integrated Search

    1982-06-01

    This report presents an evaluation of the rail portion of the Transit Reliability Information Program (TRIP), which was designed to collect and analyze equipment reliability data on U.S. transit systems. This assessment was conducted at the end of it...

  11. Distinct Neural-Functional Effects of Treatments With Selective Serotonin Reuptake Inhibitors, Electroconvulsive Therapy, and Transcranial Magnetic Stimulation and Their Relations to Regional Brain Function in Major Depression: A Meta-analysis.

    PubMed

    Chau, David T; Fogelman, Phoebe; Nordanskog, Pia; Drevets, Wayne C; Hamilton, J Paul

    2017-05-01

    Functional neuroimaging studies have examined the neural substrates of treatments for major depressive disorder (MDD). Low sample size and methodological heterogeneity, however, undermine the generalizability of findings from individual studies. We conducted a meta-analysis to identify reliable neural changes resulting from different modes of treatment for MDD and compared them with each other and with reliable neural functional abnormalities observed in depressed versus control samples. We conducted a meta-analysis of studies reporting changes in brain activity (e.g., as indexed by positron emission tomography) following treatments with selective serotonin reuptake inhibitors (SSRIs), electroconvulsive therapy (ECT), or transcranial magnetic stimulation. Additionally, we examined the statistical reliability of overlap among thresholded meta-analytic SSRI, ECT, and transcranial magnetic stimulation maps as well as a map of abnormal neural function in MDD. Our meta-analysis revealed that 1) SSRIs decrease activity in the anterior insula, 2) ECT decreases activity in central nodes of the default mode network, 3) transcranial magnetic stimulation does not result in reliable neural changes, and 4) regional effects of these modes of treatment do not significantly overlap with each other or with regions showing reliable functional abnormality in MDD. SSRIs and ECT produce neurally distinct effects relative to each other and to the functional abnormalities implicated in depression. These treatments therefore may exert antidepressant effects by diminishing neural functions not implicated in depression but that nonetheless impact mood. We discuss how the distinct neural changes resulting from SSRIs and ECT can account for both treatment effects and side effects from these therapies as well as how to individualize these treatments. Copyright © 2017 Society of Biological Psychiatry. Published by Elsevier Inc. All rights reserved.

  12. The Turkish adaptation of scale to measure patient perceptions of the quality of nursing care and related hospital services: A validity and reliability study

    PubMed Central

    Oren, Besey; Zengin, Neriman; Yildiz, Nebahat

    2016-01-01

    OBJECTIVE: This study aimed to test the validity and reliability of a version of the tool developed in Sri Lanka in 2011 to assess patient perceptions of the quality of nursing care and related hospital services created for use with Turkish patients. METHODS: This methodological study was conducted between November 2013 and November 2014 after obtaining ethical approval and organizational permission. Data was collected during discharge from 180 adult patients who were hospitalized for at least 3 days at a medical school hospital located in Istanbul. After language validation, validity and reliability analyses of the scale were conducted. Content validity, content validity index (CVI), construct validity, and exploratory factor analysis were assessed and examined, and reliability was tested using the Cronbach’s alpha coefficient and item-total correlations. RESULTS: Mean CVI was found to be 0.95, which is above expected value. Exploratory factor analysis revealed 4 factors with eigenvalues above 1, which explained 82.4% of total variance in the Turkish version of the tool to measure patient perceptions of nursing care and other hospital services. Factor loading for each item was ≥.40. Cronbach’s alpha coefficient of sub-dimensions and total scale were found to be 0.84-0.98 and 0.98, respectively. Item-total correlations ranged from 0.56 to 0.83 for the entire group, which was above expected values. CONCLUSION: The Turkish version of the scale to assess patient perceptions of the quality of nursing care and related hospital services, which comprised 4 sub-dimensions and 36 items, was found to be valid and reliable for use with the Turkish population. PMID:28275750

  13. The Turkish adaptation of scale to measure patient perceptions of the quality of nursing care and related hospital services: A validity and reliability study.

    PubMed

    Oren, Besey; Zengin, Neriman; Yildiz, Nebahat

    2016-01-01

    This study aimed to test the validity and reliability of a version of the tool developed in Sri Lanka in 2011 to assess patient perceptions of the quality of nursing care and related hospital services created for use with Turkish patients. This methodological study was conducted between November 2013 and November 2014 after obtaining ethical approval and organizational permission. Data was collected during discharge from 180 adult patients who were hospitalized for at least 3 days at a medical school hospital located in Istanbul. After language validation, validity and reliability analyses of the scale were conducted. Content validity, content validity index (CVI), construct validity, and exploratory factor analysis were assessed and examined, and reliability was tested using the Cronbach's alpha coefficient and item-total correlations. Mean CVI was found to be 0.95, which is above expected value. Exploratory factor analysis revealed 4 factors with eigenvalues above 1, which explained 82.4% of total variance in the Turkish version of the tool to measure patient perceptions of nursing care and other hospital services. Factor loading for each item was ≥.40. Cronbach's alpha coefficient of sub-dimensions and total scale were found to be 0.84-0.98 and 0.98, respectively. Item-total correlations ranged from 0.56 to 0.83 for the entire group, which was above expected values. The Turkish version of the scale to assess patient perceptions of the quality of nursing care and related hospital services, which comprised 4 sub-dimensions and 36 items, was found to be valid and reliable for use with the Turkish population.

  14. Reliability of specific physical examination tests for the diagnosis of shoulder pathologies: a systematic review and meta-analysis.

    PubMed

    Lange, Toni; Matthijs, Omer; Jain, Nitin B; Schmitt, Jochen; Lützner, Jörg; Kopkow, Christian

    2017-03-01

    Shoulder pain in the general population is common and to identify the aetiology of shoulder pain, history, motion and muscle testing, and physical examination tests are usually performed. The aim of this systematic review was to summarise and evaluate intrarater and inter-rater reliability of physical examination tests in the diagnosis of shoulder pathologies. A comprehensive systematic literature search was conducted using MEDLINE, EMBASE, Allied and Complementary Medicine Database (AMED) and Physiotherapy Evidence Database (PEDro) through 20 March 2015. Methodological quality was assessed using the Quality Appraisal of Reliability Studies (QAREL) tool by 2 independent reviewers. The search strategy revealed 3259 articles, of which 18 finally met the inclusion criteria. These studies evaluated the reliability of 62 test and test variations used for the specific physical examination tests for the diagnosis of shoulder pathologies. Methodological quality ranged from 2 to 7 positive criteria of the 11 items of the QAREL tool. This review identified a lack of high-quality studies evaluating inter-rater as well as intrarater reliability of specific physical examination tests for the diagnosis of shoulder pathologies. In addition, reliability measures differed between included studies hindering proper cross-study comparisons. PROSPERO CRD42014009018. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  15. Statistical Bayesian method for reliability evaluation based on ADT data

    NASA Astrophysics Data System (ADS)

    Lu, Dawei; Wang, Lizhi; Sun, Yusheng; Wang, Xiaohong

    2018-05-01

    Accelerated degradation testing (ADT) is frequently conducted in the laboratory to predict the products’ reliability under normal operating conditions. Two kinds of methods, degradation path models and stochastic process models, are utilized to analyze degradation data and the latter one is the most popular method. However, some limitations like imprecise solution process and estimation result of degradation ratio still exist, which may affect the accuracy of the acceleration model and the extrapolation value. Moreover, the conducted solution of this problem, Bayesian method, lose key information when unifying the degradation data. In this paper, a new data processing and parameter inference method based on Bayesian method is proposed to handle degradation data and solve the problems above. First, Wiener process and acceleration model is chosen; Second, the initial values of degradation model and parameters of prior and posterior distribution under each level is calculated with updating and iteration of estimation values; Third, the lifetime and reliability values are estimated on the basis of the estimation parameters; Finally, a case study is provided to demonstrate the validity of the proposed method. The results illustrate that the proposed method is quite effective and accuracy in estimating the lifetime and reliability of a product.

  16. Design and validation of instruments to measure knowledge.

    PubMed

    Elliott, T E; Regal, R R; Elliott, B A; Renier, C M

    2001-01-01

    Measuring health care providers' learning after they have participated in educational interventions that use experimental designs requires valid, reliable, and practical instruments. A literature review was conducted. In addition, experience gained from designing and validating instruments for measuring the effect of an educational intervention informed this process. The eight main steps for designing, validating, and testing the reliability of instruments for measuring learning outcomes are presented. The key considerations and rationale for this process are discussed. Methods for critiquing and adapting existent instruments and creating new ones are offered. This study may help other investigators in developing valid, reliable, and practical instruments for measuring the outcomes of educational activities.

  17. Development of a nerve conduction technique for the recurrent laryngeal nerve.

    PubMed

    J Kim, Sang; G Lee, Dae; Kwon, Jeong-Yi

    2014-12-01

    To develop a reliable and safe laryngeal nerve conduction technique and to obtain consistent parameters as normal reference values. A prospective single-arm study. A nerve conduction test was performed on the contralateral normal side in 42 patients with unilateral vocal fold palsy. The recording was performed in the intact thyroarytenoid muscle using a monopolar needle. The electrical stimulation using a 37-mm monopolar needle was applied 3 cm below the lower margin of the cricoid cartilage, just lateral to the trachea and medial to the carotid artery, and its intensity was gradually increased until the amplitude of the electrical response reached the maximum level. The latency of the evoked muscle response was acquired at the first evoked waveform deflection from the baseline. The average latency of the recurrent laryngeal nerves was 1.98 ± 0.26 ms. The latencies showed normal distribution according to the quantile-quantile plot and Kolmogorov-Smirnov test (P = .098). There was no significant difference in latencies between the right and left recurrent laryngeal nerves. Anthropometric factors including height and weight did not show any correlation with the latencies. We developed a reliable and safe laryngeal nerve conduction technique and obtained normal reference values for the recurrent laryngeal nerve conduction study. This laryngeal nerve conduction study can be an additional tool for detecting recurrent laryngeal nerve injury if it is performed in combination with the conventional laryngeal electromyography. 4. © 2014 The American Laryngological, Rhinological and Otological Society, Inc.

  18. Translation, cross-cultural adaptation to Brazilian- Portuguese and reliability analysis of the instrument Rapid Entire Body Assessment-REBA

    PubMed Central

    Lamarão, Andressa M.; Costa, Lucíola C. M.; Comper, Maria L. C.; Padula, Rosimeire S.

    2014-01-01

    Background: Observational instruments, such as the Rapid Entire Body Assessment, quickly assess biomechanical risks present in the workplace. However, in order to use these instruments, it is necessary to conduct the translational/cross-cultural adaptation of the instrument and test its measurement properties. Objectives: To perform the translation and the cross-cultural adaptation to Brazilian-Portuguese and test the reliability of the REBA instrument. Method: The procedures of translation and cross-cultural adaptation to Brazilian-Portuguese were conducted following proposed guidelines that involved translation, synthesis of translations, back translation, committee review and testing of the pre-final version. In addition, reliability and the intra- and inter-rater percent agreement were obtained with the Linear Weighted Kappa Coefficient that was associated with the 95% Confidence Interval and the cross tabulation 2×2. Results : The procedures for translation and adaptation were adequate and the necessary adjustments were conducted on the instrument. The intra- and inter-rater reliability showed values of 0.104 to 0.504, respectively, ranging from very poor to moderate. The percentage agreement values ranged from 5.66% to 69.81%. The percentage agreement was closer to 100% at the item 'upper arm' (69.81%) for the Intra-rater 1 and at the items 'legs' and 'upper arm' for the Intra-rater 2 (62.26%). Conclusions: The processes of translation and cross-cultural adaptation were conducted on the REBA instrument and the Brazilian version of the instrument was obtained. However, despite the reliability of the tests used to correct the translated and adapted version, the reliability values are unacceptable according to the guidelines standard, indicating that the reliability must be re-evaluated. Therefore, caution in the interpretation of the biomechanical risks measured by this instrument should be taken. PMID:25003273

  19. A study of discrete control signal fault conditions in the shuttle DPS

    NASA Technical Reports Server (NTRS)

    Reddi, S. S.; Retter, C. T.

    1976-01-01

    An analysis of the effects of discrete failures on the data processing subsystem is presented. A functional description of each discrete together with a list of software modules that use this discrete are included. A qualitative description of the consequences that may ensue due to discrete failures is given followed by a probabilistic reliability analysis of the data processing subsystem. Based on the investigation conducted, recommendations were made to improve the reliability of the subsystem.

  20. Reliability of movement control tests in the lumbar spine

    PubMed Central

    Luomajoki, Hannu; Kool, Jan; de Bruin, Eling D; Airaksinen, Olavi

    2007-01-01

    Background Movement control dysfunction [MCD] reduces active control of movements. Patients with MCD might form an important subgroup among patients with non specific low back pain. The diagnosis is based on the observation of active movements. Although widely used clinically, only a few studies have been performed to determine the test reliability. The aim of this study was to determine the inter- and intra-observer reliability of movement control dysfunction tests of the lumbar spine. Methods We videoed patients performing a standardized test battery consisting of 10 active movement tests for motor control in 27 patients with non specific low back pain and 13 patients with other diagnoses but without back pain. Four physiotherapists independently rated test performances as correct or incorrect per observation, blinded to all other patient information and to each other. The study was conducted in a private physiotherapy outpatient practice in Reinach, Switzerland. Kappa coefficients, percentage agreements and confidence intervals for inter- and intra-rater results were calculated. Results The kappa values for inter-tester reliability ranged between 0.24 – 0.71. Six tests out of ten showed a substantial reliability [k > 0.6]. Intra-tester reliability was between 0.51 – 0.96, all tests but one showed substantial reliability [k > 0.6]. Conclusion Physiotherapists were able to reliably rate most of the tests in this series of motor control tasks as being performed correctly or not, by viewing films of patients with and without back pain performing the task. PMID:17850669

  1. Telescience testbed: operational support functions for biomedical experiments.

    PubMed

    Yamashita, M; Watanabe, S; Shoji, T; Clarke, A H; Suzuki, H; Yanagihara, D

    1992-07-01

    A telescience testbed was conducted to study the methodology of space biomedicine with simulated constraints imposed on space experiments. An experimental subject selected for this testbedding was an elaborate surgery of animals and electrophysiological measurements conducted by an operator onboard. The standing potential in the ampulla of the pigeon's semicircular canal was measured during gravitational and caloric stimulation. A principal investigator, isolated from the operation site, participated in the experiment interactively by telecommunication links. Reliability analysis was applied to the whole layers of experimentation, including design of experimental objectives and operational procedures. Engineering and technological aspects of telescience are discussed in terms of reliability to assure quality of science. Feasibility of robotics was examined for supportive functions to reduce the workload of the onboard operator.

  2. Development of a Peer Teaching-Assessment Program and a Peer Observation and Evaluation Tool

    PubMed Central

    Trujillo, Jennifer M.; Barr, Judith; Gonyeau, Michael; Van Amburgh, Jenny A.; Matthews, S. James; Qualters, Donna

    2008-01-01

    Objectives To develop a formalized, comprehensive, peer-driven teaching assessment program and a valid and reliable assessment tool. Methods A volunteer taskforce was formed and a peer-assessment program was developed using a multistep, sequential approach and the Peer Observation and Evaluation Tool (POET). A pilot study was conducted to evaluate the efficiency and practicality of the process and to establish interrater reliability of the tool. Intra-class correlation coefficients (ICC) were calculated. Results ICCs for 8 separate lectures evaluated by 2-3 observers ranged from 0.66 to 0.97, indicating good interrater reliability of the tool. Conclusion Our peer assessment program for large classroom teaching, which includes a valid and reliable evaluation tool, is comprehensive, feasible, and can be adopted by other schools of pharmacy. PMID:19325963

  3. Validity and reliability of the Questionnaire for Compliance with Standard Precaution

    PubMed Central

    Valim, Marília Duarte; Marziale, Maria Helena Palucci; Hayashida, Miyeko; Rocha, Fernanda Ludmilla Rossi; Santos, Jair Lício Ferreira

    2015-01-01

    ABSTRACT OBJECTIVE : To evaluate the validity and reliability of the Questionnaire for Compliance with Standard Precaution for nurses. METHODS : This methodological study was conducted with 121 nurses from health care facilities in Sao Paulo’s countryside, who were represented by two high-complexity and by three average-complexity health care facilities. Internal consistency was calculated using Cronbach’s alpha and stability was calculated by the intraclass correlation coefficient, through test-retest. Convergent, discriminant, and known-groups construct validity techniques were conducted. RESULTS : The questionnaire was found to be reliable (Cronbach’s alpha: 0.80; intraclass correlation coefficient: (0.97) In regards to the convergent and discriminant construct validity, strong correlation was found between compliance to standard precautions, the perception of a safe environment, and the smaller perception of obstacles to follow such precautions (r = 0.614 and r = 0.537, respectively). The nurses who were trained on the standard precautions and worked on the health care facilities of higher complexity were shown to comply more (p = 0.028 and p = 0.006, respectively). CONCLUSIONS : The Brazilian version of the Questionnaire for Compliance with Standard Precaution was shown to be valid and reliable. Further investigation must be conducted with nurse samples that are more representative of the Brazilian reality. The use of the questionnaire may support the creation of educational measures considering the possible gaps that can be identified, focusing on the workers’ health and on the patients’ safety. PMID:26759967

  4. A proposed method to investigate reliability throughout a questionnaire.

    PubMed

    Wentzel-Larsen, Tore; Norekvål, Tone M; Ulvik, Bjørg; Nygård, Ottar; Pripp, Are H

    2011-10-05

    Questionnaires are used extensively in medical and health care research and depend on validity and reliability. However, participants may differ in interest and awareness throughout long questionnaires, which can affect reliability of their answers. A method is proposed for "screening" of systematic change in random error, which could assess changed reliability of answers. A simulation study was conducted to explore whether systematic change in reliability, expressed as changed random error, could be assessed using unsupervised classification of subjects by cluster analysis (CA) and estimation of intraclass correlation coefficient (ICC). The method was also applied on a clinical dataset from 753 cardiac patients using the Jalowiec Coping Scale. The simulation study showed a relationship between the systematic change in random error throughout a questionnaire and the slope between the estimated ICC for subjects classified by CA and successive items in a questionnaire. This slope was proposed as an awareness measure--to assessing if respondents provide only a random answer or one based on a substantial cognitive effort. Scales from different factor structures of Jalowiec Coping Scale had different effect on this awareness measure. Even though assumptions in the simulation study might be limited compared to real datasets, the approach is promising for assessing systematic change in reliability throughout long questionnaires. Results from a clinical dataset indicated that the awareness measure differed between scales.

  5. Developing a Mathematics Education Quality Scale

    ERIC Educational Resources Information Center

    Ciftci, S. Koza; Karadag, Engin

    2016-01-01

    The aim of this study was to evaluate students' perceptions of the quality of mathematics education and to develop a reliable and valid measurement tool. The research was conducted with 638 (first study) and 407 (second study) secondary school students in Eskisehir, Turkey. Item discrimination, structural validity (exploratory factor analysis and…

  6. Bicultural Work Motivation Scale for Asian American College Students

    ERIC Educational Resources Information Center

    Chen, Yung-Lung; Fouad, Nadya A.

    2016-01-01

    The bicultural work motivations of Asian Americans have not yet been comprehensively captured by contemporary vocational constructs and scales. For this study, we conducted two studies on the initial reliability and validity of the Bicultural Work Motivation Scale (BWMS) by combining qualitative and quantitative methods. First, a pilot study was…

  7. Standardization of Brief Inventory of Social Support Exchange Network (BISSEN) in Japan.

    PubMed

    Aiba, Miyuki; Tachikawa, Hirokazu; Fukuoka, Yoshiharu; Lebowitz, Adam; Shiratori, Yuki; Doi, Nagafumi; Matsui, Yutaka

    2017-07-01

    This study describes the Brief Inventory of Social Support Exchange Network (BISSEN) as a standardized brief inventory measuring various aspects of social support. We confirmed the reliability and validity for function and direction of support and standardized the BISSEN. For Sample 1, a stratified random sampling method was used to select 5200 residents in Japan. We conducted mail surveys and responses were retrieved from 2274 participants (collection rate 43.7%). Participants completed a questionnaire packet that included BISSEN, suicidal ideation, depression, support seeking, and Multidimensional Scale of Perceived Social Support (MSPSS). Sample 2 surveys for test-retest reliability were conducted on 23 residents at approximately two-week intervals. Participants were asked about gender, age, and BISSEN. First, we assessed the internal consistency, test-retest reliability, construct, convergent, and concurrent validity. McDonald's omega (.73-.92) and test-retest correlations (.78-.85) demonstrated adequate internal consistency and test-retest reliability. Depression, support seeking, and MSPSS were significantly correlated with all scores of BISSEN. The non-suicidal ideation group had significantly more support compared to the suicidal ideation group. Therefore, function and direction of support in BISSEN had sufficient reliability and validity. Next, we standardized BISSEN using Z-scores and percentile rank with respect to each 12 norm groups by age and gender. Copyright © 2017 Elsevier Ireland Ltd. All rights reserved.

  8. Flexible Transparent Conductive Films with High Performance and Reliability Using Hybrid Structures of Continuous Metal Nanofiber Networks for Flexible Optoelectronics.

    PubMed

    Park, Juyoung; Hyun, Byung Gwan; An, Byeong Wan; Im, Hyeon-Gyun; Park, Young-Geun; Jang, Junho; Park, Jang-Ung; Bae, Byeong-Soo

    2017-06-21

    We report an Ag nanofiber-embedded glass-fabric reinforced hybrimer (AgNF-GFRHybrimer) composite film as a reliable and high-performance flexible transparent conducting film. The continuous AgNF network provides superior optoelectronic properties of the composite film by minimizing transmission loss and junction resistance. In addition, the excellent thermal/chemical stability and mechanical durability of the GFRHybrimer matrix provides enhanced mechanical durability and reliability of the final AgNF-GFRHybrimer composite film. To demonstrate the availability of our AgNF-GFRHybrimer composite as a transparent conducting film, we fabricated a flexible organic light-emitting diode (OLED) device on the AgNF-GFRHybrimer film; the OLED showed stable operation during a flexing.

  9. Reliability of a computer and Internet survey (Computer User Profile) used by adults with and without traumatic brain injury (TBI).

    PubMed

    Kilov, Andrea M; Togher, Leanne; Power, Emma

    2015-01-01

    To determine test-re-test reliability of the 'Computer User Profile' (CUP) in people with and without TBI. The CUP was administered on two occasions to people with and without TBI. The CUP investigated the nature and frequency of participants' computer and Internet use. Intra-class correlation coefficients and kappa coefficients were conducted to measure reliability of individual CUP items. Descriptive statistics were used to summarize content of responses. Sixteen adults with TBI and 40 adults without TBI were included in the study. All participants were reliable in reporting demographic information, frequency of social communication and leisure activities and computer/Internet habits and usage. Adults with TBI were reliable in 77% of their responses to survey items. Adults without TBI were reliable in 88% of their responses to survey items. The CUP was practical and valuable in capturing information about social, leisure, communication and computer/Internet habits of people with and without TBI. Adults without TBI scored more items with satisfactory reliability overall in their surveys. Future studies may include larger samples and could also include an exploration of how people with/without TBI use other digital communication technologies. This may provide further information on determining technology readiness for people with TBI in therapy programmes.

  10. Understanding and Visualizing Multitasking and Task Switching Activities: A Time Motion Study to Capture Nursing Workflow

    PubMed Central

    Yen, Po-Yin; Kelley, Marjorie; Lopetegui, Marcelo; Rosado, Amber L.; Migliore, Elaina M.; Chipps, Esther M.; Buck, Jacalyn

    2016-01-01

    A fundamental understanding of multitasking within nursing workflow is important in today’s dynamic and complex healthcare environment. We conducted a time motion study to understand nursing workflow, specifically multitasking and task switching activities. We used TimeCaT, a comprehensive electronic time capture tool, to capture observational data. We established inter-observer reliability prior to data collection. We completed 56 hours of observation of 10 registered nurses. We found, on average, nurses had 124 communications and 208 hands-on tasks per 4-hour block of time. They multitasked (having communication and hands-on tasks simultaneously) 131 times, representing 39.48% of all times; the total multitasking duration ranges from 14.6 minutes to 109 minutes, 44.98 minutes (18.63%) on average. We also reviewed workflow visualization to uncover the multitasking events. Our study design and methods provide a practical and reliable approach to conducting and analyzing time motion studies from both quantitative and qualitative perspectives. PMID:28269924

  11. Understanding and Visualizing Multitasking and Task Switching Activities: A Time Motion Study to Capture Nursing Workflow.

    PubMed

    Yen, Po-Yin; Kelley, Marjorie; Lopetegui, Marcelo; Rosado, Amber L; Migliore, Elaina M; Chipps, Esther M; Buck, Jacalyn

    2016-01-01

    A fundamental understanding of multitasking within nursing workflow is important in today's dynamic and complex healthcare environment. We conducted a time motion study to understand nursing workflow, specifically multitasking and task switching activities. We used TimeCaT, a comprehensive electronic time capture tool, to capture observational data. We established inter-observer reliability prior to data collection. We completed 56 hours of observation of 10 registered nurses. We found, on average, nurses had 124 communications and 208 hands-on tasks per 4-hour block of time. They multitasked (having communication and hands-on tasks simultaneously) 131 times, representing 39.48% of all times; the total multitasking duration ranges from 14.6 minutes to 109 minutes, 44.98 minutes (18.63%) on average. We also reviewed workflow visualization to uncover the multitasking events. Our study design and methods provide a practical and reliable approach to conducting and analyzing time motion studies from both quantitative and qualitative perspectives.

  12. Magnetoacoustic tomography with magnetic induction for high-resolution bioimepedance imaging through vector source reconstruction under the static field of MRI magnet.

    PubMed

    Mariappan, Leo; Hu, Gang; He, Bin

    2014-02-01

    Magnetoacoustic tomography with magnetic induction (MAT-MI) is an imaging modality to reconstruct the electrical conductivity of biological tissue based on the acoustic measurements of Lorentz force induced tissue vibration. This study presents the feasibility of the authors' new MAT-MI system and vector source imaging algorithm to perform a complete reconstruction of the conductivity distribution of real biological tissues with ultrasound spatial resolution. In the present study, using ultrasound beamformation, imaging point spread functions are designed to reconstruct the induced vector source in the object which is used to estimate the object conductivity distribution. Both numerical studies and phantom experiments are performed to demonstrate the merits of the proposed method. Also, through the numerical simulations, the full width half maximum of the imaging point spread function is calculated to estimate of the spatial resolution. The tissue phantom experiments are performed with a MAT-MI imaging system in the static field of a 9.4 T magnetic resonance imaging magnet. The image reconstruction through vector beamformation in the numerical and experimental studies gives a reliable estimate of the conductivity distribution in the object with a ∼ 1.5 mm spatial resolution corresponding to the imaging system frequency of 500 kHz ultrasound. In addition, the experiment results suggest that MAT-MI under high static magnetic field environment is able to reconstruct images of tissue-mimicking gel phantoms and real tissue samples with reliable conductivity contrast. The results demonstrate that MAT-MI is able to image the electrical conductivity properties of biological tissues with better than 2 mm spatial resolution at 500 kHz, and the imaging with MAT-MI under a high static magnetic field environment is able to provide improved imaging contrast for biological tissue conductivity reconstruction.

  13. Inter-rater reliability of direct observations of the physical and psychosocial working conditions in eldercare: An evaluation in the DOSES project.

    PubMed

    Karstad, Kristina; Rugulies, Reiner; Skotte, Jørgen; Munch, Pernille Kold; Greiner, Birgit A; Burdorf, Alex; Søgaard, Karen; Holtermann, Andreas

    2018-05-01

    The aim of the study was to develop and evaluate the reliability of the "Danish observational study of eldercare work and musculoskeletal disorders" (DOSES) observation instrument to assess physical and psychosocial risk factors for musculoskeletal disorders (MSD) in eldercare work. During 1.5 years, sixteen raters conducted 117 inter-rater observations from 11 nursing homes. Reliability was evaluated using percent agreement and Gwet's AC1 coefficient. Of the 18 examined items, inter-rater reliability was excellent for 7 items (AC1>0.75) fair to good for 7 items (AC1 0.40-0.75) and poor for 2 items (AC1 0-0.40). For 2 items there was no agreement between the raters (AC1 <0). The reliability did not differ between the first and second half of the data collection period and the inter-rater observations were representative regarding occurrence of events in eldercare work. The instrument is appropriate for assessing physical and psychosocial risk factors for MSD among eldercare workers. Copyright © 2018 The Authors. Published by Elsevier Ltd.. All rights reserved.

  14. Psychometric evaluation of the Persian version of the Templer's Death Anxiety Scale in cancer patients.

    PubMed

    Soleimani, Mohammad Ali; Yaghoobzadeh, Ameneh; Bahrami, Nasim; Sharif, Saeed Pahlevan; Sharif Nia, Hamid

    2016-10-01

    In this study, 398 Iranian cancer patients completed the 15-item Templer's Death Anxiety Scale (TDAS). Tests of internal consistency, principal components analysis, and confirmatory factor analysis were conducted to assess the internal consistency and factorial validity of the Persian TDAS. The construct reliability statistic and average variance extracted were also calculated to measure construct reliability, convergent validity, and discriminant validity. Principal components analysis indicated a 3-component solution, which was generally supported in the confirmatory analysis. However, acceptable cutoffs for construct reliability, convergent validity, and discriminant validity were not fulfilled for the three subscales that were derived from the principal component analysis. This study demonstrated both the advantages and potential limitations of using the TDAS with Persian-speaking cancer patients.

  15. Preliminary design and analysis of an advanced rotorcraft transmission

    NASA Technical Reports Server (NTRS)

    Henry, Z. S.

    1990-01-01

    Future rotorcraft transmissions of the 1990s and beyond the year 2000 require the incorporation of key emerging material and component technologies using advanced and innovative design practices in order to meet the requirements for a reduced weight-to-power ratio, a decreased noise level, and a substantially increased reliability. The specific goals for future rotocraft transmissions when compared with current state-of-the-art transmissions are a 25 percent weight reduction, a 10-dB reduction in the transmitted noise level, and a system reliability of 5000 hours mean-time-between-removal for the transmission. This paper presents the results of the design studies conducted to meet the stated goals for an advanced rotorcraft transmission. These design studies include system configuration, planetary gear train selection, and reliability prediction methods.

  16. Pilot Study: Survey Tools for Assessing Parenting Styles and Family Contributors to the Development of Obesity in Arab Children Ages 6 to 12 Years.

    PubMed

    Tami, Suzan H; Reed, Debra B; Trejos, Elizabeth; Boylan, Mallory; Wang, Shu

    2015-11-05

    Our pilot study was conducted to test the reliability of the Caregiver's Feeding Styles Questionnaire (CFSQ) and the Family Nutrition and Physical Activity Assessment (FNPA) in a sample of Arab mothers. Twenty-five Arab mothers completed the CFSQ, FNPA, and the Participant Background Survey for the first administration. After 1-2 weeks, participants completed the CFSQ and the FNPA for the second administration. The two administrations of the surveys allowed for test/retest reliability of the CFSQ and the FNPA and to measure the internal consistency of the two surveys. Pearson's correlation between the first and second administrations or the 19-item scale (demandingness) and the 7-item scale (responsiveness) of the CFSQ were .95 and .86, respectively. As for the FNPA, Pearson's correlation was .80. The estimated reliabilities (Cronbach's alpha) of the CFSQ increased from .86 for the first administration to .93 for the second administration. However, the estimated reliabilities of the FNPA slightly increased from .58 for first administration to .59 for the second administration. In our pilot study of Arab mothers, the CFSQ and FNPA were shown to be promising in terms of reliability and content validity.

  17. Volunteer Functions Inventory: A systematic review.

    PubMed

    Chacón, Fernando; Gutiérrez, Gema; Sauto, Verónica; Vecina, María L; Pérez, Alfonso

    2017-08-01

    The objective of this research study was to conduct a systematic review of the research on volunteers using Clary et al.’s VFI (1998). A total of 48 research studies including 67 independent samples met eligibility criteria. The total sample of the studies analyzed ranged from 20375 to 21988 participants, depending on the motivation analyzed. The results show that the Values factor obtained the highest mean score, both overall and in each type of volunteering, whereas the lowest scores were for the Career and Enhancement factors. Studies conducted with samples with a mean age under 40 years obtain higher scores on Career and Understanding scales when compared to studies in older samples. The group of studies with less than 50% women yield higher mean scores on the Social scale than studies with more than 50% women in the sample. All the scales show reliability coefficients between .78 and .84. Only eight of the articles provide data on the reliability of the scale with a mean value of .90. Of the 26 studies that performed factor analysis, 18 confirmed the original structure of six factors.

  18. Reliability and validity of a nutrition and physical activity environmental self-assessment for child care

    PubMed Central

    Benjamin, Sara E; Neelon, Brian; Ball, Sarah C; Bangdiwala, Shrikant I; Ammerman, Alice S; Ward, Dianne S

    2007-01-01

    Background Few assessment instruments have examined the nutrition and physical activity environments in child care, and none are self-administered. Given the emerging focus on child care settings as a target for intervention, a valid and reliable measure of the nutrition and physical activity environment is needed. Methods To measure inter-rater reliability, 59 child care center directors and 109 staff completed the self-assessment concurrently, but independently. Three weeks later, a repeat self-assessment was completed by a sub-sample of 38 directors to assess test-retest reliability. To assess criterion validity, a researcher-administered environmental assessment was conducted at 69 centers and was compared to a self-assessment completed by the director. A weighted kappa test statistic and percent agreement were calculated to assess agreement for each question on the self-assessment. Results For inter-rater reliability, kappa statistics ranged from 0.20 to 1.00 across all questions. Test-retest reliability of the self-assessment yielded kappa statistics that ranged from 0.07 to 1.00. The inter-quartile kappa statistic ranges for inter-rater and test-retest reliability were 0.45 to 0.63 and 0.27 to 0.45, respectively. When percent agreement was calculated, questions ranged from 52.6% to 100% for inter-rater reliability and 34.3% to 100% for test-retest reliability. Kappa statistics for validity ranged from -0.01 to 0.79, with an inter-quartile range of 0.08 to 0.34. Percent agreement for validity ranged from 12.9% to 93.7%. Conclusion This study provides estimates of criterion validity, inter-rater reliability and test-retest reliability for an environmental nutrition and physical activity self-assessment instrument for child care. Results indicate that the self-assessment is a stable and reasonably accurate instrument for use with child care interventions. We therefore recommend the Nutrition and Physical Activity Self-Assessment for Child Care (NAP SACC) instrument to researchers and practitioners interested in conducting healthy weight intervention in child care. However, a more robust, less subjective measure would be more appropriate for researchers seeking an outcome measure to assess intervention impact. PMID:17615078

  19. Organizational readiness for implementing change: a psychometric assessment of a new measure.

    PubMed

    Shea, Christopher M; Jacobs, Sara R; Esserman, Denise A; Bruce, Kerry; Weiner, Bryan J

    2014-01-10

    Organizational readiness for change in healthcare settings is an important factor in successful implementation of new policies, programs, and practices. However, research on the topic is hindered by the absence of a brief, reliable, and valid measure. Until such a measure is developed, we cannot advance scientific knowledge about readiness or provide evidence-based guidance to organizational leaders about how to increase readiness. This article presents results of a psychometric assessment of a new measure called Organizational Readiness for Implementing Change (ORIC), which we developed based on Weiner's theory of organizational readiness for change. We conducted four studies to assess the psychometric properties of ORIC. In study one, we assessed the content adequacy of the new measure using quantitative methods. In study two, we examined the measure's factor structure and reliability in a laboratory simulation. In study three, we assessed the reliability and validity of an organization-level measure of readiness based on aggregated individual-level data from study two. In study four, we conducted a small field study utilizing the same analytic methods as in study three. Content adequacy assessment indicated that the items developed to measure change commitment and change efficacy reflected the theoretical content of these two facets of organizational readiness and distinguished the facets from hypothesized determinants of readiness. Exploratory and confirmatory factor analysis in the lab and field studies revealed two correlated factors, as expected, with good model fit and high item loadings. Reliability analysis in the lab and field studies showed high inter-item consistency for the resulting individual-level scales for change commitment and change efficacy. Inter-rater reliability and inter-rater agreement statistics supported the aggregation of individual level readiness perceptions to the organizational level of analysis. This article provides evidence in support of the ORIC measure. We believe this measure will enable testing of theories about determinants and consequences of organizational readiness and, ultimately, assist healthcare leaders to reduce the number of health organization change efforts that do not achieve desired benefits. Although ORIC shows promise, further assessment is needed to test for convergent, discriminant, and predictive validity.

  20. Organizational readiness for implementing change: a psychometric assessment of a new measure

    PubMed Central

    2014-01-01

    Background Organizational readiness for change in healthcare settings is an important factor in successful implementation of new policies, programs, and practices. However, research on the topic is hindered by the absence of a brief, reliable, and valid measure. Until such a measure is developed, we cannot advance scientific knowledge about readiness or provide evidence-based guidance to organizational leaders about how to increase readiness. This article presents results of a psychometric assessment of a new measure called Organizational Readiness for Implementing Change (ORIC), which we developed based on Weiner’s theory of organizational readiness for change. Methods We conducted four studies to assess the psychometric properties of ORIC. In study one, we assessed the content adequacy of the new measure using quantitative methods. In study two, we examined the measure’s factor structure and reliability in a laboratory simulation. In study three, we assessed the reliability and validity of an organization-level measure of readiness based on aggregated individual-level data from study two. In study four, we conducted a small field study utilizing the same analytic methods as in study three. Results Content adequacy assessment indicated that the items developed to measure change commitment and change efficacy reflected the theoretical content of these two facets of organizational readiness and distinguished the facets from hypothesized determinants of readiness. Exploratory and confirmatory factor analysis in the lab and field studies revealed two correlated factors, as expected, with good model fit and high item loadings. Reliability analysis in the lab and field studies showed high inter-item consistency for the resulting individual-level scales for change commitment and change efficacy. Inter-rater reliability and inter-rater agreement statistics supported the aggregation of individual level readiness perceptions to the organizational level of analysis. Conclusions This article provides evidence in support of the ORIC measure. We believe this measure will enable testing of theories about determinants and consequences of organizational readiness and, ultimately, assist healthcare leaders to reduce the number of health organization change efforts that do not achieve desired benefits. Although ORIC shows promise, further assessment is needed to test for convergent, discriminant, and predictive validity. PMID:24410955

  1. An In vitro evaluation of the reliability of QR code denture labeling technique

    PubMed Central

    Poovannan, Sindhu; Jain, Ashish R.; Krishnan, Cakku Jalliah Venkata; Chandran, Chitraa R.

    2016-01-01

    Statement of Problem: Positive identification of the dead after accidents and disasters through labeled dentures plays a key role in forensic scenario. A number of denture labeling methods are available, and studies evaluating their reliability under drastic conditions are vital. Aim: This study was conducted to evaluate the reliability of QR (Quick Response) Code labeled at various depths in heat-cured acrylic blocks after acid treatment, heat treatment (burns), and fracture in forensics. It was an in vitro study. Materials and Methods: This study included 160 specimens of heat-cured acrylic blocks (1.8 cm × 1.8 cm) and these were divided into 4 groups (40 samples per group). QR Codes were incorporated in the samples using clear acrylic sheet and they were assessed for reliability under various depths, acid, heat, and fracture. Data were analyzed using Chi-square test, test of proportion. Results: The QR Code inclusion technique was reliable under various depths of acrylic sheet, acid (sulfuric acid 99%, hydrochloric acid 40%) and heat (up to 370°C). Results were variable with fracture of QR Code labeled acrylic blocks. Conclusion: Within the limitations of the study, by analyzing the results, it was clearly indicated that the QR Code technique was reliable under various depths of acrylic sheet, acid, and heat (370°C). Effectiveness varied in fracture and depended on the level of distortion. This study thus suggests that QR Code is an effective and simpler denture labeling method. PMID:28123284

  2. Concordance and Reliability of Photogrammetric Protocols for Measuring the Cervical Lordosis Angle: A Systematic Review of the Literature.

    PubMed

    de Albuquerque, Priscila Maria Nascimento Martins; de Alencar, Geisa Guimarães; de Oliveira, Daniela Araújo; de Siqueira, Gisela Rocha

    2018-01-01

    The aim of this study was to examine and interpret the concordance, accuracy, and reliability of photogrammetric protocols available in the literature for evaluating cervical lordosis in an adult population aged 18 to 59 years. A systematic search of 6 electronic databases (MEDLINE via PubMed, LILACS, CINAHL, Scopus, ScienceDirect, and Web of Science) located studies that assessed the reliability and/or concordance and/or accuracy of photogrammetric protocols for evaluating cervical lordosis, compared with radiography. Articles published through April 2016 were selected. Two independent reviewers used a critical appraisal tool (QUADAS and QAREL) to assess the quality of the selected studies. Two studies were included in the review and had high levels of reliability (intraclass correlation coefficient: 0.974-0.98). Only 1 study assessed the concordance between the methods, which was calculated using Pearson's correlation coefficient. To date, the accuracy of photogrammetry has not been investigated thoroughly. We encountered no study in the literature that investigated the accuracy of photogrammetry in diagnosing hyperlordosis of cervical spine. However, both current studies report high levels of intra- and interrater reliability. To increase the level of evidence of photogrammetry in the evaluation of cervical lordosis, it is necessary to conduct further studies using a larger sample to increase the external validity of the findings. Copyright © 2018. Published by Elsevier Inc.

  3. Creation of a ceramics handbook

    NASA Technical Reports Server (NTRS)

    Craft, W. J.; Filatovs, G. J.

    1974-01-01

    A study was conducted to develop a ceramics handbook defining properties and parameters necessary for thermostructural design. Continuing efforts toward this goal, and in particular toward the evolution of a reliable predictor of fracture from current literature, are described.

  4. An interrater reliability study of the Braden scale in two nursing homes.

    PubMed

    Kottner, Jan; Dassen, Theo

    2008-10-01

    Adequate risk assessment is essential in pressure ulcer prevention. Assessment scales were designed to support practitioners in identifying persons at pressure ulcer risk. The Braden scale is one of the most extensively studied risk assessment instruments, although the majority of studies focused on validity rather than reliability. The first aim was to measure the interrater reliability of the Braden scale and its individual items. The second aim was to study different statistical approaches regarding interrater reliability estimation. An interrater reliability study was conducted in two German nursing homes. Residents (n = 152) from 8 units were assessed twice. The raters were trained nurses with a work experience ranging from 0.5 to 30 years. Data were analysed using an overall percentage of agreement, weighted and unweighted kappa and the intraclass correlation coefficient. Differences between nurses rating the overall Braden score ranged from 0 up to 9 points. Interrater reliability expressed by the intraclass correlation coefficient ranged from 0.73 (95% CI 0.26 - 0.91) to 0.95 (95% CI 0.87 - 0.98). Calculated intraclass correlation coefficients for individual items ranged from 0.06 (95% CI -0.31 to 0.48) to 0.97 (95% CI 0.93-0.99) with the lowest values being measured for the items "sensory perception" and "nutrition". There was no association between work experience and the level of interrater reliability. With two exceptions, simple kappa-values were always lower than weighted kappa-values and intraclass correlation coefficients. Although the calculated interrater reliability coefficients for the total Braden score were high in some cases, several clinically relevant differences occurred between the nurses. Due to interrater reliability being very low for the items "sensory perception" and "nutrition", it is doubtful if their assessment contributes to any valid results. The calculation of weighted kappa or intraclass correlation coefficients is the most appropriate interrater reliability estimates.

  5. The Baptist Health Nurse Retention Questionnaire: A Methodological Study, Part 1.

    PubMed

    Lengerich, Alexander; Bugajski, Andrew; Marchese, Matthew; Hall, Brittany; Yackzan, Susan; Davies, Claire; Brockopp, Dorothy

    2017-05-01

    The purposes of this study were to develop and test the Baptist Health Nurse Retention Questionnaire (BHNRQ) and examine the importance of nurse retention factors. Multiple factors, including increasing patient acuity levels, have led to concerns regarding nurse retention. An understanding of current factors related to retention is limited. To establish the psychometric properties of the BHNRQ, data were collected from 279 bedside nurses at a 391-bed, Magnet® redesignated community hospital. A principal component analysis was conducted to determine the subscale structure of the BHNRQ. Additional analyses were conducted related to content validity and test-retest reliability. The results of the principal components analysis revealed 3 subscales: nursing practice, management, and staffing. Analyses demonstrate that the BHNRQ is a reliable and valid instrument for measuring nurse retention factors. The BHNRQ was found to be a clinically useful instrument for measuring important factors related to nurse retention.

  6. Validation of the Spanish Version of the Psychological Sense of School Membership (PSSM) Scale in Chilean Adolescents and Its Association with School-Related Outcomes and Substance Use

    PubMed Central

    Gaete, Jorge; Montero-Marin, Jesus; Rojas-Barahona, Cristian A.; Olivares, Esterbina; Araya, Ricardo

    2016-01-01

    School membership appears to be an important factor in explaining the relationship between students and schools, including school staff. School membership is associated with several school-related outcomes, such as academic performance and expectations. Most studies on school membership have been conducted in developed countries. The Psychological Sense of School Membership (PSSM) scale (18 items: 13 positively worded items, 5 negatively worded items) has been widely used to measure this construct, but no studies regarding its validity and reliability have been conducted in Spanish-speaking Latin American countries. This study investigates the psychometric properties, factor structure and reliability of this scale in a sample of 1250 early adolescents in Chile. Both exploratory and confirmatory factor analyses provide evidence of an excellent fit for a one-factor solution after removing the negatively worded items. The internal consistency of this new abbreviated version was 0.92. The association analyses demonstrated that high school membership was associated with better academic performance, stronger school bonding, a reduced likelihood of school misbehavior, and reduced likelihood of substance use. Analyses showed support for the reliability and validity of the PSSM among Chilean adolescents. PMID:27999554

  7. Validity and Reliability of Field-Based Measures for Assessing Movement Skill Competency in Lifelong Physical Activities: A Systematic Review.

    PubMed

    Hulteen, Ryan M; Lander, Natalie J; Morgan, Philip J; Barnett, Lisa M; Robertson, Samuel J; Lubans, David R

    2015-10-01

    It has been suggested that young people should develop competence in a variety of 'lifelong physical activities' to ensure that they can be active across the lifespan. The primary aim of this systematic review is to report the methodological properties, validity, reliability, and test duration of field-based measures that assess movement skill competency in lifelong physical activities. A secondary aim was to clearly define those characteristics unique to lifelong physical activities. A search of four electronic databases (Scopus, SPORTDiscus, ProQuest, and PubMed) was conducted between June 2014 and April 2015 with no date restrictions. Studies addressing the validity and/or reliability of lifelong physical activity tests were reviewed. Included articles were required to assess lifelong physical activities using process-oriented measures, as well as report either one type of validity or reliability. Assessment criteria for methodological quality were adapted from a checklist used in a previous review of sport skill outcome assessments. Movement skill assessments for eight different lifelong physical activities (badminton, cycling, dance, golf, racquetball, resistance training, swimming, and tennis) in 17 studies were identified for inclusion. Methodological quality, validity, reliability, and test duration (time to assess a single participant), for each article were assessed. Moderate to excellent reliability results were found in 16 of 17 studies, with 71% reporting inter-rater reliability and 41% reporting intra-rater reliability. Only four studies in this review reported test-retest reliability. Ten studies reported validity results; content validity was cited in 41% of these studies. Construct validity was reported in 24% of studies, while criterion validity was only reported in 12% of studies. Numerous assessments for lifelong physical activities may exist, yet only assessments for eight lifelong physical activities were included in this review. Generalizability of results may be more applicable if more heterogeneous samples are used in future research. Moderate to excellent levels of inter- and intra-rater reliability were reported in the majority of studies. However, future work should look to establish test-retest reliability. Validity was less commonly reported than reliability, and further types of validity other than content validity need to be established in future research. Specifically, predictive validity of 'lifelong physical activity' movement skill competency is needed to support the assertion that such activities provide the foundation for a lifetime of activity.

  8. Use of electromagnetic-terrain conductivity and DC-resistivity profiling techniques for bedrock characterization at the 15th-of-May City extension, Cairo, Egypt

    NASA Astrophysics Data System (ADS)

    Aly, Said A.; Farag, Karam S. I.; Atya, Magdy A.; Badr, Mohamed A. M.

    2018-06-01

    A joint multi-spacing electromagnetic-terrain conductivity meter and DC-resistivity horizontal profiling survey was conducted at the anticipated eastern extensional area of the 15th-of-May City, southeastern Cairo, Egypt. The main objective of the survey was to highlight the applicability, efficiency, and reliability of utilizing such non-invasive surface techniques in a field like geologic mapping, and hence to image both the vertical and lateral electrical resistivity structures of the subsurface bedrock. Consequently, a total of reliable 6 multi-spacing electromagnetic-terrain conductivity meter and 7 DC-resistivity horizontal profiles were carried out between August 2016 and February 2017. All data sets were transformed-inverted extensively and consistently in terms of two-dimensional (2D) electrical resistivity smoothed-earth models. They could be used effectively and inexpensively to interpret the area's bedrock geologic sequence using the encountered consecutive electrically resistive and conductive anomalies. Notably, the encountered subsurface electrical resistivity structures, below all surveying profiles, are correlated well with the mapped geological faults in the field. They even could provide a useful understanding of their faulting fashion. Absolute resistivity values were not necessarily diagnostic, but their vertical and lateral variations could provide more diagnostic information about the layer lateral extensions and thicknesses, and hence suggested reliable geo-electric earth models. The study demonstrated that a detailed multi-spacing electromagnetic-terrain conductivity meter and DC-resistivity horizontal profiling survey can help design an optimal geotechnical investigative program, not only for the whole eastern extensional area of the 15th-of-May City, but also for the other new urban communities within the Egyptian desert.

  9. Patient-reported outcome instruments that evaluate adherence behaviours in adults with asthma: A systematic review of measurement properties.

    PubMed

    Gagné, Myriam; Boulet, Louis-Philippe; Pérez, Norma; Moisan, Jocelyne

    2018-04-30

    To systematically identify the measurement properties of patient-reported outcome instruments (PROs) that evaluate adherence to inhaled maintenance medication in adults with asthma. We conducted a systematic review of six databases. Two reviewers independently included studies on the measurement properties of PROs that evaluated adherence in asthmatic participants aged ≥18 years. Based on the COnsensus-based Standards for the selection of health Measurement INstruments (COSMIN), the reviewers (1) extracted data on internal consistency, reliability, measurement error, content validity, structural validity, hypotheses testing, cross-cultural validity, criterion validity, and responsiveness; (2) assessed the methodological quality of the included studies; (3) assessed the quality of the measurement properties (positive or negative); and (4) summarised the level of evidence (limited, moderate, or strong). We screened 6,068 records and included 15 studies (14 PROs). No studies evaluated measurement error or responsiveness. Based on methodological and measurement property quality assessments, we found limited positive evidence of: (a) internal consistency of the Adherence Questionnaire, Refined Medication Adherence Reason Scale (MAR-Scale), Medication Adherence Report Scale for Asthma (MARS-A), and Test of the Adherence to Inhalers (TAI); (b) reliability of the TAI; and (c) structural validity of the Adherence Questionnaire, MAR-Scale, MARS-A, and TAI. We also found limited negative evidence of: (d) hypotheses testing of Adherence Questionnaire; (e) reliability of the MARS-A; and (f) criterion validity of the MARS-A and TAI. Our results highlighted the need to conduct further high-quality studies that will positively evaluate the reliability, validity, and responsiveness of the available PROs. This article is protected by copyright. All rights reserved.

  10. EVALUATION OF STATIONARY SOURCE PARTICULATE MEASUREMENT METHODS. VOLUME II. OIL-FIRED STEAM GENERATORS

    EPA Science Inventory

    An experimental study was conducted to determine the reliability of the Method 5 procedure for providing particulate emission data from an oil-fired steam generator. The study was concerned with determining whether any 'false' particulate resulted from the collection process of f...

  11. A Validation of the Student Risk Screening Scale for Internalizing and Externalizing Behaviors: Patterns in Rural and Urban Elementary Schools

    ERIC Educational Resources Information Center

    Lane, Kathleen Lynne; Menzies, Holly M.; Oakes, Wendy P.; Lambert, Warren; Cox, Meredith; Hankins, Katy

    2012-01-01

    We report findings of two studies, one conducted in a rural school district (N = 982) and a second conducted in an urban district (N = 1,079), offering additional evidence of the reliability and validity of a revised instrument, the Student Risk Screening Scale-Internalizing and Externalizing (SRSS-IE), to accurately detect internalizing and…

  12. Development and reliability of a structured interview guide for the Montgomery Asberg Depression Rating Scale (SIGMA).

    PubMed

    Williams, Janet B W; Kobak, Kenneth A

    2008-01-01

    The Montgomery-Asberg Depression Rating Scale (MADRS) is often used in clinical trials to select patients and to assess treatment efficacy. The scale was originally published without suggested questions for clinicians to use in gathering the information necessary to rate the items. Structured and semi-structured interview guides have been found to improve reliability with other scales. To describe the development and test-retest reliability of a structured interview guide for the MADRS (SIGMA). A total of 162 test-retest interviews were conducted by 81 rater pairs. Each patient was interviewed twice, once by each rater conducting an independent interview. The intraclass correlation for total score between raters using the SIGMA was r=0.93, P<0.0001. All ten items had good to excellent interrater reliability. Use of the SIGMA can result in high reliability of MADRS scores in evaluating patients with depression.

  13. Test-Retest Reliability of Pediatric Heart Rate Variability: A Meta-Analysis.

    PubMed

    Weiner, Oren M; McGrath, Jennifer J

    2017-01-01

    Heart rate variability (HRV), an established index of autonomic cardiovascular modulation, is associated with health outcomes (e.g., obesity, diabetes) and mortality risk. Time- and frequency-domain HRV measures are commonly reported in longitudinal adult and pediatric studies of health. While test-retest reliability has been established among adults, less is known about the psychometric properties of HRV among infants, children, and adolescents. The objective was to conduct a meta-analysis of the test-retest reliability of time- and frequency-domain HRV measures from infancy to adolescence. Electronic searches (PubMed, PsycINFO; January 1970-December 2014) identified studies with nonclinical samples aged ≤ 18 years; ≥ 2 baseline HRV recordings separated by ≥ 1 day; and sufficient data for effect size computation. Forty-nine studies ( N = 5,170) met inclusion criteria. Methodological variables coded included factors relevant to study protocol, sample characteristics, electrocardiogram (ECG) signal acquisition and preprocessing, and HRV analytical decisions. Fisher's Z was derived as the common effect size. Analyses were age-stratified (infant/toddler < 5 years, n = 3,329; child/adolescent 5-18 years, n = 1,841) due to marked methodological differences across the pediatric literature. Meta-analytic results revealed HRV demonstrated moderate reliability; child/adolescent studies ( Z = 0.62, r = 0.55) had significantly higher reliability than infant/toddler studies ( Z = 0.42, r = 0.40). Relative to other reported measures, HF exhibited the highest reliability among infant/toddler studies ( Z = 0.42, r = 0.40), while rMSSD exhibited the highest reliability among child/adolescent studies ( Z = 1.00, r = 0.76). Moderator analyses indicated greater reliability with shorter test-retest interval length, reported exclusion criteria based on medical illness/condition, lower proportion of males, prerecording acclimatization period, and longer recording duration; differences were noted across age groups. HRV is reliable among pediatric samples. Reliability is sensitive to pertinent methodological decisions that require careful consideration by the researcher. Limited methodological reporting precluded several a priori moderator analyses. Suggestions for future research, including standards specified by Task Force Guidelines, are discussed.

  14. Test-Retest Reliability of Pediatric Heart Rate Variability

    PubMed Central

    Weiner, Oren M.; McGrath, Jennifer J.

    2017-01-01

    Heart rate variability (HRV), an established index of autonomic cardiovascular modulation, is associated with health outcomes (e.g., obesity, diabetes) and mortality risk. Time- and frequency-domain HRV measures are commonly reported in longitudinal adult and pediatric studies of health. While test-retest reliability has been established among adults, less is known about the psychometric properties of HRV among infants, children, and adolescents. The objective was to conduct a meta-analysis of the test-retest reliability of time- and frequency-domain HRV measures from infancy to adolescence. Electronic searches (PubMed, PsycINFO; January 1970–December 2014) identified studies with nonclinical samples aged ≤ 18 years; ≥ 2 baseline HRV recordings separated by ≥ 1 day; and sufficient data for effect size computation. Forty-nine studies (N = 5,170) met inclusion criteria. Methodological variables coded included factors relevant to study protocol, sample characteristics, electrocardiogram (ECG) signal acquisition and preprocessing, and HRV analytical decisions. Fisher’s Z was derived as the common effect size. Analyses were age-stratified (infant/toddler < 5 years, n = 3,329; child/adolescent 5–18 years, n = 1,841) due to marked methodological differences across the pediatric literature. Meta-analytic results revealed HRV demonstrated moderate reliability; child/adolescent studies (Z = 0.62, r = 0.55) had significantly higher reliability than infant/toddler studies (Z = 0.42, r = 0.40). Relative to other reported measures, HF exhibited the highest reliability among infant/toddler studies (Z = 0.42, r = 0.40), while rMSSD exhibited the highest reliability among child/adolescent studies (Z = 1.00, r = 0.76). Moderator analyses indicated greater reliability with shorter test-retest interval length, reported exclusion criteria based on medical illness/condition, lower proportion of males, prerecording acclimatization period, and longer recording duration; differences were noted across age groups. HRV is reliable among pediatric samples. Reliability is sensitive to pertinent methodological decisions that require careful consideration by the researcher. Limited methodological reporting precluded several a priori moderator analyses. Suggestions for future research, including standards specified by Task Force Guidelines, are discussed. PMID:29307951

  15. Some critical issues in the characterization of nanoscale thermal conductivity by molecular dynamics analysis

    NASA Astrophysics Data System (ADS)

    Ehsan Khaled, Mohammad; Zhang, Liangchi; Liu, Weidong

    2018-07-01

    The nanoscale thermal conductivity of a material can be significantly different from its value at the macroscale. Although a number of studies using the equilibrium molecular dynamics (EMD) with Green–Kubo (GK) formula have been conducted for nano-conductivity predictions, there are many problems in the analysis that have made the EMD results unreliable or misleading. This paper aims to clarify such critical issues through a thorough investigation on the effect and determination of the vital physical variables in the EMD-GK analysis, using the prediction of the nanoscale thermal conductivity of Si as an example. The study concluded that to have a reliable prediction, quantum correction, time step, simulation time, correlation time and system size are all crucial.

  16. Performance of stress-laminated timber highway bridges in cold climates

    Treesearch

    James P. Wacker

    2009-01-01

    This paper summarizes recent laboratory and field data studies on thermal performance of stress-laminated timber highway bridges. Concerns about the reliability of stress-laminated deck bridges when exposed to sub-freezing temperatures triggered several investigations. Two laboratory studies were conducted to study the effects of wood species, preservative, moisture...

  17. Internalized HIV Stigma and Disclosure Concerns: Development and Validation of Two Scales in Spanish-Speaking Populations.

    PubMed

    Hernansaiz-Garrido, Helena; Alonso-Tapia, Jesús

    2017-01-01

    Internalized stigma and disclosure concerns are key elements for the study of mental health in people living with HIV. Since no measures of these constructs were available for Spanish population, this study sought to develop such instruments, to analyze their reliability and validity and to provide a short version. A heterogeneous sample of 458 adults from different Spanish-speaking countries completed the HIV-Internalized Stigma Scale and the HIV-Disclosure Concerns Scale, along with the Hospital Anxiety and Depression Scale, Rosenberg's Self-esteem Scale and other socio-demographic variables. Reliability and correlation analyses, exploratory factor analyses, path analyses with latent variables, and ANOVAs were conducted to test the scales' psychometric properties. The scales showed good reliability in terms of internal consistency and temporal stability, as well as good sensitivity and factorial and criterion validity. The HIV-Internalized Stigma Scale and the HIV-Disclosure Concerns Scale are reliable and valid means to assess these variables in several contexts.

  18. Elaboration and Validation of the Medication Prescription Safety Checklist 1

    PubMed Central

    Pires, Aline de Oliveira Meireles; Ferreira, Maria Beatriz Guimarães; do Nascimento, Kleiton Gonçalves; Felix, Márcia Marques dos Santos; Pires, Patrícia da Silva; Barbosa, Maria Helena

    2017-01-01

    ABSTRACT Objective: to elaborate and validate a checklist to identify compliance with the recommendations for the structure of medication prescriptions, based on the Protocol of the Ministry of Health and the Brazilian Health Surveillance Agency. Method: methodological research, conducted through the validation and reliability analysis process, using a sample of 27 electronic prescriptions. Results: the analyses confirmed the content validity and reliability of the tool. The content validity, obtained by expert assessment, was considered satisfactory as it covered items that represent the compliance with the recommendations regarding the structure of the medication prescriptions. The reliability, assessed through interrater agreement, was excellent (ICC=1.00) and showed perfect agreement (K=1.00). Conclusion: the Medication Prescription Safety Checklist showed to be a valid and reliable tool for the group studied. We hope that this study can contribute to the prevention of adverse events, as well as to the improvement of care quality and safety in medication use. PMID:28793128

  19. CardioGuard: A Brassiere-Based Reliable ECG Monitoring Sensor System for Supporting Daily Smartphone Healthcare Applications

    PubMed Central

    Kwon, Sungjun; Kim, Jeehoon; Kang, Seungwoo; Lee, Youngki; Baek, Hyunjae

    2014-01-01

    Abstract We propose CardioGuard, a brassiere-based reliable electrocardiogram (ECG) monitoring sensor system, for supporting daily smartphone healthcare applications. It is designed to satisfy two key requirements for user-unobtrusive daily ECG monitoring: reliability of ECG sensing and usability of the sensor. The system is validated through extensive evaluations. The evaluation results showed that the CardioGuard sensor reliably measure the ECG during 12 representative daily activities including diverse movement levels; 89.53% of QRS peaks were detected on average. The questionnaire-based user study with 15 participants showed that the CardioGuard sensor was comfortable and unobtrusive. Additionally, the signal-to-noise ratio test and the washing durability test were conducted to show the high-quality sensing of the proposed sensor and its physical durability in practical use, respectively. PMID:25405527

  20. Construction and Validation of the Perceived Opportunity to Craft Scale.

    PubMed

    van Wingerden, Jessica; Niks, Irene M W

    2017-01-01

    We developed and validated a scale to measure employees' perceived opportunity to craft (POC) in two separate studies conducted in the Netherlands (total N = 2329). POC is defined as employees' perception of their opportunity to craft their job. In Study 1, the perceived opportunity to craft scale (POCS) was developed and tested for its factor structure and reliability in an explorative way. Study 2 consisted of confirmatory analyses of the factor structure and reliability of the scale as well as examination of the discriminant and criterion-related validity of the POCS. The results indicated that the scale consists of one dimension and could be reliably measured with five items. Evidence was found for the discriminant validity of the POCS. The scale also showed criterion-related validity when correlated with job crafting (+), job resources (autonomy +; opportunities for professional development +), work engagement (+), and the inactive construct cynicism (-). We discuss the implications of these findings for theory and practice.

  1. Validated Questionnaire of Maternal Attitude and Knowledge for Predicting Caries Risk in Children: Epidemiological Study in North Jakarta, Indonesia.

    PubMed

    Laksmiastuti, Sri Ratna; Budiardjo, Sarworini Bagio; Sutadi, Heriandi

    2017-06-01

    Predicting caries risk in children can be done by identifying caries risk factors. It is an important measure which contributes to best understanding of the cariogenic profile of the patient. Identification could be done by clinical examination and answering the questionnaire. We arrange the study to verify the questionnaire validation for predicting caries risk in children. The study was conducted on 62 pairs of mothers and their children, aged between 3 and 5 years. The questionnaire consists of 10 questions concerning mothers' attitude and knowledge about oral health. The reliability and validity test is based on Cronbach's alpha and correlation coefficient value. All question are reliable (Cronbach's alpha = 0.873) and valid (Corrected item-total item correlation >0.4). Five questionnaires of mother's attitude about oral health and five questionnaires of mother's knowledge about oral health are reliable and valid for predicting caries risk in children.

  2. An Independent Evaluation of the FMEA/CIL Hazard Analysis Alternative Study

    NASA Technical Reports Server (NTRS)

    Ray, Paul S.

    1996-01-01

    The present instruments of safety and reliability risk control for a majority of the National Aeronautics and Space Administration (NASA) programs/projects consist of Failure Mode and Effects Analysis (FMEA), Hazard Analysis (HA), Critical Items List (CIL), and Hazard Report (HR). This extensive analytical approach was introduced in the early 1970's and was implemented for the Space Shuttle Program by NHB 5300.4 (1D-2. Since the Challenger accident in 1986, the process has been expanded considerably and resulted in introduction of similar and/or duplicated activities in the safety/reliability risk analysis. A study initiated in 1995, to search for an alternative to the current FMEA/CIL Hazard Analysis methodology generated a proposed method on April 30, 1996. The objective of this Summer Faculty Study was to participate in and conduct an independent evaluation of the proposed alternative to simplify the present safety and reliability risk control procedure.

  3. Spike propagation through the dorsal root ganglia in an unmyelinated sensory neuron: a modeling study

    PubMed Central

    Sundt, Danielle; Gamper, Nikita

    2015-01-01

    Unmyelinated C-fibers are a major type of sensory neurons conveying pain information. Action potential conduction is regulated by the bifurcation (T-junction) of sensory neuron axons within the dorsal root ganglia (DRG). Understanding how C-fiber signaling is influenced by the morphology of the T-junction and the local expression of ion channels is important for understanding pain signaling. In this study we used biophysical computer modeling to investigate the influence of axon morphology within the DRG and various membrane conductances on the reliability of spike propagation. As expected, calculated input impedance and the amplitude of propagating action potentials were both lowest at the T-junction. Propagation reliability for single spikes was highly sensitive to the diameter of the stem axon and the density of voltage-gated Na+ channels. A model containing only fast voltage-gated Na+ and delayed-rectifier K+ channels conducted trains of spikes up to frequencies of 110 Hz. The addition of slowly activating KCNQ channels (i.e., KV7 or M-channels) to the model reduced the following frequency to 30 Hz. Hyperpolarization produced by addition of a much slower conductance, such as a Ca2+-dependent K+ current, was needed to reduce the following frequency to 6 Hz. Attenuation of driving force due to ion accumulation or hyperpolarization produced by a Na+-K+ pump had no effect on following frequency but could influence the reliability of spike propagation mutually with the voltage shift generated by a Ca2+-dependent K+ current. These simulations suggest how specific ion channels within the DRG may contribute toward therapeutic treatments for chronic pain. PMID:26334005

  4. Implementation of a combined algorithm designed to increase the reliability of information systems: simulation modeling

    NASA Astrophysics Data System (ADS)

    Popov, A.; Zolotarev, V.; Bychkov, S.

    2016-11-01

    This paper examines the results of experimental studies of a previously submitted combined algorithm designed to increase the reliability of information systems. The data that illustrates the organization and conduct of the studies is provided. Within the framework of a comparison of As a part of the study conducted, the comparison of the experimental data of simulation modeling and the data of the functioning of the real information system was made. The hypothesis of the homogeneity of the logical structure of the information systems was formulated, thus enabling to reconfigure the algorithm presented, - more specifically, to transform it into the model for the analysis and prediction of arbitrary information systems. The results presented can be used for further research in this direction. The data of the opportunity to predict the functioning of the information systems can be used for strategic and economic planning. The algorithm can be used as a means for providing information security.

  5. Translation and validation of the assistive technology device predisposition assessment in Greek in order to assess satisfaction with use of the selected assistive device.

    PubMed

    Koumpouros, Yiannis; Papageorgiou, Effie; Karavasili, Alexandra; Alexopoulou, Despoina

    2017-07-01

    To examine the Assistive Technology Device Predisposition Assessment scale and provide evidence of validity and reliability of the Greek version. We translated and adapted the original instrument in Greek according to the most well-known guidelines recommendations. Field test studies were conducted in a rehabilitation hospital to validate the appropriateness of the final results. Ratings of the different items were statistically analyzed. We recruited 115 subjects who were administered the Form E of the original questionnaire. The experimental analysis conducted revealed a three subscales structure: (i) Adaptability, (ii) Fit to Use, and (iii) Socializing. According to the results of our study the three subscales measure different constructs. Reliability measures (ICC = 0.981, Pearson's correlation = 0.963, Cronbach's α = 0.701) yielded high values. Test-retest outcome showed great stability. This is the first study, at least to the knowledge of the authors, which focuses merely on measuring the satisfaction of the users from the used assistive device, while exploring the Assistive Technology Device Predisposition Assessment - Device Form in such depth. According to the results, it is a stable, valid and reliable instrument and applicable to the Greek population. Thus, it can be used to measure the satisfaction of patients with assistive devices. Implications for Rehabilitation The paper explores the cultural adaptability and applicability of ATD PA - Device Form. ATD PA - Device Form can be used to assess user satisfaction by the selected assistive device. ATD PA - Device Form is a valid and reliable instrument in measuring users' satisfaction in Greekreality.

  6. Indicating spinal joint mobilisations or manipulations in patients with neck or low-back pain: protocol of an inter-examiner reliability study among manual therapists.

    PubMed

    van Trijffel, Emiel; Lindeboom, Robert; Bossuyt, Patrick Mm; Schmitt, Maarten A; Lucas, Cees; Koes, Bart W; Oostendorp, Rob Ab

    2014-01-01

    Manual spinal joint mobilisations and manipulations are widely used treatments in patients with neck and low-back pain. Inter-examiner reliability of passive intervertebral motion assessment of the cervical and lumbar spine, perceived as important for indicating these interventions, is poor within a univariable approach. The diagnostic process as a whole in daily practice in manual therapy has a multivariable character, however, in which the use and interpretation of passive intervertebral motion assessment depend on earlier results from the diagnostic process. To date, the inter-examiner reliability among manual therapists of a multivariable diagnostic decision-making process in patients with neck or low-back pain is unknown. This study will be conducted as a repeated-measures design in which 14 pairs of manual therapists independently examine a consecutive series of a planned total of 165 patients with neck or low-back pain presenting in primary care physiotherapy. Primary outcome measure is therapists' decision about whether or not manual spinal joint mobilisations or manipulations, or both, are indicated in each patient, alone or as part of a multimodal treatment. Therapists will largely be free to conduct the full diagnostic process based on their formulated examination objectives. For each pair of therapists, 2×2 tables will be constructed and reliability for the dichotomous decision will be expressed using Cohen's kappa. In addition, observed agreement, prevalence of positive decisions, prevalence index, bias index, and specific agreement in positive and negative decisions will be calculated. Univariable logistic regression analysis of concordant decisions will be performed to explore which demographic, professional, or clinical factors contributed to reliability. This study will provide an estimate of the inter-examiner reliability among manual therapists of indicating spinal joint mobilisations or manipulations in patients with neck or low-back pain based on a multivariable diagnostic reasoning and decision-making process, as opposed to reliability of individual tests. As such, it is proposed as an initial step toward the development of an alternative approach to current classification systems and prediction rules for identifying those patients with spinal disorders that may show a better response to manual therapy which can be incorporated in randomised clinical trials. Potential methodological limitations of this study are discussed.

  7. Indicating spinal joint mobilisations or manipulations in patients with neck or low-back pain: protocol of an inter-examiner reliability study among manual therapists

    PubMed Central

    2014-01-01

    Background Manual spinal joint mobilisations and manipulations are widely used treatments in patients with neck and low-back pain. Inter-examiner reliability of passive intervertebral motion assessment of the cervical and lumbar spine, perceived as important for indicating these interventions, is poor within a univariable approach. The diagnostic process as a whole in daily practice in manual therapy has a multivariable character, however, in which the use and interpretation of passive intervertebral motion assessment depend on earlier results from the diagnostic process. To date, the inter-examiner reliability among manual therapists of a multivariable diagnostic decision-making process in patients with neck or low-back pain is unknown. Methods This study will be conducted as a repeated-measures design in which 14 pairs of manual therapists independently examine a consecutive series of a planned total of 165 patients with neck or low-back pain presenting in primary care physiotherapy. Primary outcome measure is therapists’ decision about whether or not manual spinal joint mobilisations or manipulations, or both, are indicated in each patient, alone or as part of a multimodal treatment. Therapists will largely be free to conduct the full diagnostic process based on their formulated examination objectives. For each pair of therapists, 2×2 tables will be constructed and reliability for the dichotomous decision will be expressed using Cohen’s kappa. In addition, observed agreement, prevalence of positive decisions, prevalence index, bias index, and specific agreement in positive and negative decisions will be calculated. Univariable logistic regression analysis of concordant decisions will be performed to explore which demographic, professional, or clinical factors contributed to reliability. Discussion This study will provide an estimate of the inter-examiner reliability among manual therapists of indicating spinal joint mobilisations or manipulations in patients with neck or low-back pain based on a multivariable diagnostic reasoning and decision-making process, as opposed to reliability of individual tests. As such, it is proposed as an initial step toward the development of an alternative approach to current classification systems and prediction rules for identifying those patients with spinal disorders that may show a better response to manual therapy which can be incorporated in randomised clinical trials. Potential methodological limitations of this study are discussed. PMID:24982754

  8. Test-retest reliability of the proposed DSM-5 eating disorder diagnostic criteria

    PubMed Central

    Sysko, Robyn; Roberto, Christina A.; Barnes, Rachel D.; Grilo, Carlos M.; Attia, Evelyn; Walsh, B. Timothy

    2012-01-01

    The proposed DSM-5 classification scheme for eating disorders includes both major and minor changes to the existing DSM-IV diagnostic criteria. It is not known what effect these modifications will have on the ability to make reliable diagnoses. Two studies were conducted to evaluate the short-term test-retest reliability of the proposed DSM-5 eating disorder diagnoses: anorexia nervosa, bulimia nervosa, binge eating disorder, and feeding and eating conditions not elsewhere classified. Participants completed two independent telephone interviews with research assessors (n=70 Study 1; n=55 Study 2). Fair to substantial agreements (κ= 0.80 and 0.54) were observed across eating disorder diagnoses in Study 1 and Study 2, respectively. Acceptable rates of agreement were identified for the individual eating disorder diagnoses, including DSM-5 anorexia nervosa (κ’s of 0.81 to 0.97), bulimia nervosa (κ=0.84), binge eating disorder (κ’s of 0.75 and 0.61), and feeding and eating disorders not elsewhere classified (κ’s of 0.70 and 0.46). Further, improved short-term test-retest reliability was noted when using the DSM-5, in comparison to DSM-IV, criteria for binge eating disorder. Thus, these studies found that trained interviewers can reliably diagnose eating disorders using the proposed DSM-5 criteria; however, additional data from general practice settings and community samples are needed. PMID:22401974

  9. Brief Report: An Exploratory Study of the Diagnostic Reliability for Autism Spectrum Disorder

    ERIC Educational Resources Information Center

    Taylor, Lauren J.; Eapen, Valsamma; Maybery, Murray; Midford, Sue; Paynter, Jessica; Quarmby, Lyndsay; Smith, Timothy; Williams, Katrina; Whitehouse, Andrew J.

    2017-01-01

    Previous research shows inconsistency in clinician-assigned diagnoses of Autism Spectrum Disorder (ASD). We conducted an exploratory study that examined the concordance of diagnoses between a multidisciplinary assessment team and a range of independent clinicians throughout Australia. Nine video-taped Autism Diagnostic Observation Schedule (ADOS)…

  10. Computational studies on the excited state properties of citrinin and application in fluorescence analysis

    USDA-ARS?s Scientific Manuscript database

    Citrinin is a mycotoxin of increasing concern that is produced by fungi associated with maize, red yeast rice, and other agricultural commodities. A comprehensive time-dependent density functional study on the excited state properties of citrinin was conducted to identify parameters for reliable det...

  11. Reasons for Avoidance of Vocational Education in Jordan

    ERIC Educational Resources Information Center

    Al-Saaideh, Mon'im A.

    2016-01-01

    The study aimed to identify the factors that lead students to avoid joining Vocational Education (VE) in Jordan. A pilot study was conducted, then a 39-item questionnaire was developed, and its validity and reliability were ensured. The reasons included were divided into personal, social, economic, educational and vocational domains. The…

  12. Key Skills Influencing Student Achievement

    ERIC Educational Resources Information Center

    Balch, Tonya; Gruenert, Steve

    2009-01-01

    A predictive, non-experimental, cross-sectional design (Johnson, 2001) was used to conduct a study to determine if elementary administrators' key counseling skills and select demographics predicted state-level student performance indicators in their respective schools. A secondary purpose of this study was to develop a valid and reliable on-line…

  13. Reliability of IGBT in a STATCOM for Harmonic Compensation and Power Factor Correction

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gopi Reddy, Lakshmi Reddy; Tolbert, Leon M; Ozpineci, Burak

    With smart grid integration, there is a need to characterize reliability of a power system by including reliability of power semiconductors in grid related applications. In this paper, the reliability of IGBTs in a STATCOM application is presented for two different applications, power factor correction and harmonic elimination. The STATCOM model is developed in EMTP, and analytical equations for average conduction losses in an IGBT and a diode are derived and compared with experimental data. A commonly used reliability model is used to predict reliability of IGBT.

  14. 76 FR 23801 - North American Electric Reliability Corporation; Order Approving Reliability Standard

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-04-28

    ... primary control functionality. Nonetheless, until data from drills, exercises and tests can support a... control center becomes inoperable and to conduct reviews and tests, at least annually, to ensure viability... Preparedness and Operations (EOP) Reliability Standard EOP- 008-1 (Loss of Control Center Functionality). The...

  15. Reliability and Validity of the Evidence-Based Practice Confidence (EPIC) Scale

    ERIC Educational Resources Information Center

    Salbach, Nancy M.; Jaglal, Susan B.; Williams, Jack I.

    2013-01-01

    Introduction: The reliability, minimal detectable change (MDC), and construct validity of the evidence-based practice confidence (EPIC) scale were evaluated among physical therapists (PTs) in clinical practice. Methods: A longitudinal mail survey was conducted. Internal consistency and test-retest reliability were estimated using Cronbach's alpha…

  16. 78 FR 63172 - Commission Information Collection Activities (FERC-733); Comment Request

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-10-23

    ... Electric Reliability Corporation (NERC) and EIA, to fielding and collecting data using a FERC designed... Commission in time to complete the 2014 report to Congress. NERC, as the Electric Reliability Organization... dispatchable and non-dispatchable resources that it needs to conduct its reliability work. Reporting demand...

  17. Sexual behavioral abstine HIV/AIDS questionnaire: Validation study of an Iranian questionnaire.

    PubMed

    Najarkolaei, Fatemeh Rahmati; Niknami, Shamsaddin; Shokravi, Farkhondeh Amin; Tavafian, Sedigheh Sadat; Fesharaki, Mohammad Gholami; Jafari, Mohammad Reza

    2014-01-01

    This study was designed to assess the validity and reliability of the designed sexual, behavioral abstinence, and avoidance of high-risk situation questionnaire (SBAHAQ), with an aim to construct an appropriate development tool in the Iranian population. A descriptive-analytic study was conducted among female undergraduate students of Tehran University, who were selected through cluster random sampling. After reviewing the questionnaires and investigating face and content validity, internal consistency of the questionnaire was assessed by Cronbach's alpha. Explanatory and confirmatory factor analysis was conducted using SPSS and AMOS 16 Software, respectively. The sample consisted of 348 female university students with a mean age of 20.69 ± 1.63 years. The content validity ratio (CVR) coefficient was 0.85 and the reliability of each section of the questionnaire was as follows: Perceived benefit (PB; 0.87), behavioral intention (BI; 0.77), and self-efficacy (SE; 0.85) (Cronbach's alpha totally was 0.83). Explanatory factor analysis showed three factors, including SE, PB, and BI, with the total variance of 61% and Kaiser-Meyer-Olkin (KMO) index of 88%. These factors were also confirmed by confirmatory factor analysis [adjusted goodness of fitness index (AGFI) = 0.939, root mean square error of approximation (RMSEA) = 0.039]. This study showed the designed questionnaire provided adequate construct validity and reliability, and could be adequately used to measure sexual abstinence and avoidance of high-risk situations among female students.

  18. Substance use disorders: Diagnostic and Statistical Manual of Mental Disorders, fourth edition (DSM-IV) and International Classification of Diseases, tenth edition (ICD-10).

    PubMed

    Hasin, Deborah; Hatzenbuehler, Mark L; Keyes, Katherine; Ogburn, Elizabeth

    2006-09-01

    Two major nomenclatures, Diagnostic and Statistical Manual of Mental Disorders, fourth edition (DSM-IV) and International Classification of Diseases, tenth edition (ICD-10), currently define substance use disorders for broad audiences of users with different training, experience and interests. A comparison of these definitions and their implications for DSM-V and ICD-11 has not been available. The background for the dependence concept and abuse, harmful use, withdrawal, substance-induced disorders and remission and other substance-related conditions is reviewed. Reliability evidence is presented, as is validity evidence from approaches including psychometric, genetic and animal studies. The relevance of the DSM-IV and ICD-10 compared to alternative systems (e.g. the Addiction Severity Index) is considered. Reliability and psychometric validity evidence for substance dependence is consistently strong, but more mixed for abuse and harmful use. Findings on the genetics of alcohol disorders support the validity of the dependence concept, while animal studies underscore the centrality of continued use despite negative consequences to the concept of dependence. While few studies on substance-induced disorders have been conducted, those published show good reliability and validity when elements of DSM-IV and ICD-10 are combined. Dependence in DSM-V and ICD-11 should be retained, standardizing both criteria sets and adding a severity measure. The consequences of heavy use should be measured independently of dependence; add cannabis withdrawal if further research supports existing evidence; conduct further studies of the substance-induced psychiatric categories; standardize their criteria across DSM-V and ICD-11; develop a theoretical basis for better remission criteria; consider changing substance 'abuse' to substance 'dysfunction disorder'; and conduct clinician education on the value of the diagnostic criteria.

  19. Design guidelines for use of adhesives and organic coatings in hybrid microcircuits

    NASA Technical Reports Server (NTRS)

    Caruso, S. V.; Licari, J. J.; Perkins, K. L.; Schramm, W. A.

    1974-01-01

    A study was conducted to investigate the reliability of organic adhesives in hybrid microcircuits. The objectives were twofold: (1) to identify and investigate problem areas that could result from the use of organic adhesives and (2) to develop evaluation tests to quantify the extent to which these problems occur for commercially available adhesives. Efforts were focused on electrically conductive adhesives. Also, a study was made to evaluate selected organic coatings for contamination protection for hybrid microcircuits.

  20. The development and validation of a test of science critical thinking for fifth graders.

    PubMed

    Mapeala, Ruslan; Siew, Nyet Moi

    2015-01-01

    The paper described the development and validation of the Test of Science Critical Thinking (TSCT) to measure the three critical thinking skill constructs: comparing and contrasting, sequencing, and identifying cause and effect. The initial TSCT consisted of 55 multiple choice test items, each of which required participants to select a correct response and a correct choice of critical thinking used for their response. Data were obtained from a purposive sampling of 30 fifth graders in a pilot study carried out in a primary school in Sabah, Malaysia. Students underwent the sessions of teaching and learning activities for 9 weeks using the Thinking Maps-aided Problem-Based Learning Module before they answered the TSCT test. Analyses were conducted to check on difficulty index (p) and discrimination index (d), internal consistency reliability, content validity, and face validity. Analysis of the test-retest reliability data was conducted separately for a group of fifth graders with similar ability. Findings of the pilot study showed that out of initial 55 administered items, only 30 items with relatively good difficulty index (p) ranged from 0.40 to 0.60 and with good discrimination index (d) ranged within 0.20-1.00 were selected. The Kuder-Richardson reliability value was found to be appropriate and relatively high with 0.70, 0.73 and 0.92 for identifying cause and effect, sequencing, and comparing and contrasting respectively. The content validity index obtained from three expert judgments equalled or exceeded 0.95. In addition, test-retest reliability showed good, statistically significant correlations ([Formula: see text]). From the above results, the selected 30-item TSCT was found to have sufficient reliability and validity and would therefore represent a useful tool for measuring critical thinking ability among fifth graders in primary science.

  1. Indirect Measurement of Sexual Orientation: Comparison of the Implicit Relational Assessment Procedure, Viewing Time, and Choice Reaction Time Tasks.

    PubMed

    Rönspies, Jelena; Schmidt, Alexander F; Melnikova, Anna; Krumova, Rosina; Zolfagari, Asadeh; Banse, Rainer

    2015-07-01

    The present study was conducted to validate an adaptation of the Implicit Relational Assessment Procedure (IRAP) as an indirect latency-based measure of sexual orientation. Furthermore, reliability and criterion validity of the IRAP were compared to two established indirect measures of sexual orientation: a Choice Reaction Time task (CRT) and a Viewing Time (VT) task. A sample of 87 heterosexual and 35 gay men completed all three indirect measures in an online study. The IRAP and the VT predicted sexual orientation nearly perfectly. Both measures also showed a considerable amount of convergent validity. Reliabilities (internal consistencies) reached satisfactory levels. In contrast, the CRT did not tap into sexual orientation in the present study. In sum, the VT measure performed best, with the IRAP showing only slightly lower reliability and criterion validity, whereas the CRT did not yield any evidence of reliability or criterion validity in the present research. The results were discussed in the light of specific task properties of the indirect latency-based measures (task-relevance vs. task-irrelevance).

  2. Reliability and validity of a Tutorial Group Effectiveness Instrument.

    PubMed

    Singaram, Veena S; Van Der Vleuten, Cees P M; Van Berkel, Henk; Dolmans, Diana H J M

    2010-01-01

    Tutorial group effectiveness is essential for the success of learning in problem-based learning (PBL). Less effective and dysfunctional groups compromise the quality of students learning in PBL. This article aims to report on the reliability and validity of an instrument aimed at measuring tutorial group effectiveness in PBL. The items within the instrument are clustered around motivational and cognitive factors based on Slavin's theoretical framework. A confirmatory factor analysis (CFA) was carried out to estimate the validity of the instrument. Furthermore, generalizability studies were conducted and alpha coefficients were computed to determine the reliability and homogeneity of each factor. The CFA indicated that a three-factor model comprising 19 items showed a good fit with the data. Alpha coefficients per factor were high. The findings of the generalizability studies indicated that at least 9-10 student responses are needed in order to obtain reliable data at the tutorial group level. The instrument validated in this study has the potential to provide faculty and students with diagnostic information and feedback about student behaviors that enhance and hinder tutorial group effectiveness.

  3. Electrical characterization of FIB processed metal layers for reliable conductive-AFM on ZnO microstructures

    NASA Astrophysics Data System (ADS)

    Pea, M.; Maiolo, L.; Giovine, E.; Rinaldi, A.; Araneo, R.; Notargiacomo, A.

    2016-05-01

    We report on the conductive-atomic force microscopy (C-AFM) study of metallic layers in order to find the most suitable configuration for electrical characterization of individual ZnO micro-pillars fabricated by focused ion beam (FIB). The electrical resistance between the probe tip and both as deposited and FIB processed metal layers (namely, Cr, Ti, Au and Al) has been investigated. Both chromium and titanium evidenced a non homogenous and non ohmic behaviour, non negligible scanning probe induced anodic oxidation associated to electrical measurements, and after FIB milling they exhibited significantly higher tip-sample resistance. Aluminium had generally a more apparent non conductive behaviour. Conversely, gold films showed very good tip-sample conduction properties being less sensitive to FIB processing than the other investigated metals. We found that a reliable C-AFM electrical characterization of ZnO microstructures obtained by FIB machining is feasible by using a combination of metal films as top contact layer. An Au/Ti bilayer on top of ZnO was capable to sustain the FIB fabrication process and to form a suitable ohmic contact to the semiconductor, allowing for reliable C-AFM measurement. To validate the consistency of this approach, we measured the resistance of ZnO micropillars finding a linear dependence on the pillar height, as expected for an ohmic conductor, and evaluated the resistivity of the material. This procedure has the potential to be downscaled to nanometer size structures by a proper choice of metal films type and thickness.

  4. Mental Health Services in Pilot Study Areas: Report on a European Study.

    ERIC Educational Resources Information Center

    World Health Organization, Copenhagen (Denmark). Regional Office for Europe.

    The World Health Organization (WHO) conducted a study to collect data on mental health resources of pilot areas within several European countries. This report presents data from the study and provides a detailed and reliable description of the development of mental health services within the WHO European Region. Part I of the report describes the…

  5. A proposal to study the experience of female scientists in Mexico: Physicists as a case study

    NASA Astrophysics Data System (ADS)

    Martínez, Amalia; Blázquez, Norma; Gómez, Yolanda; Vales, Caridad; Meza-Montes, Lilia

    2013-03-01

    Although the design of public policies to support and improve the status and opportunities for female scientists requires reliable data, studies of this type have not been done in Mexico. We present a proposal to conduct such a study at the national level, with physicists as a test group.

  6. Adapting Depression and Anxiety Questionnaire for Children into Turkish: Reliability and Validity Studies

    ERIC Educational Resources Information Center

    Ay, Ismail; Secer, Ismail; Simsek, Mustafa Kerim

    2017-01-01

    Purpose of this study is to adapt anxiety and depression questionnaire for children into Turkish culture and to analyze the psychometric characteristics of it on clinical and nonclinical samples separately. The study is a descriptive survey research. The study was conducted on two different sample groups, clinical and nonclinical. The clinical…

  7. [Evaluation and application of the Korean version of the sexuality attitudes and beliefs survey for nurses].

    PubMed

    Kim, Hae Won; Jung, Yeon Yi; Park, Seungmi

    2012-12-01

    This study was conducted to evaluate the validity and reliability of the Korean version of the Sexuality Attitudes and Beliefs Survey (SABS) and to assess SABS for Korean nurses. The Korean version of SABS was developed through forward-backward translation techniques. Internal consistency reliability and construct validity using confirmatory factor analysis were conducted using PASW+ PC Win (18.0) and AMOS (18.0). Data were collected from 567 nurses who worked in one of six general hospitals across the country. The Korean version of SABS showed a reliable internal consistency with Cronbach's α of subscales ranging from .59 to .73. Factor loadings of the 10 items of three subscales ranged from .38 to .83. The three subscales model were validated by confirmatory factor analysis (GFI>.97, RMSEA<.05). Sexuality attitudes and beliefs for Korean nurses were more negative than that of European or American nurses. The SABS scores for Korean nurses were significantly different according to age, marriage, education, clinical experiences, and feeling about sexuality. The Korean version of SABS has satisfactory construct validity and reliability to measure Korean nurses' attitudes and belief toward sexuality. Education is essential to enhance importance and self-efficacy and to relieve barriers to addressing patients' sexuality.

  8. Development and validation of the Simulation Learning Effectiveness Inventory.

    PubMed

    Chen, Shiah-Lian; Huang, Tsai-Wei; Liao, I-Chen; Liu, Chienchi

    2015-10-01

    To develop and psychometrically test the Simulation Learning Effectiveness Inventory. High-fidelity simulation helps students develop clinical skills and competencies. Yet, reliable instruments measuring learning outcomes are scant. A descriptive cross-sectional survey was used to validate psychometric properties of the instrument measuring students' perception of stimulation learning effectiveness. A purposive sample of 505 nursing students who had taken simulation courses was recruited from a department of nursing of a university in central Taiwan from January 2010-June 2010. The study was conducted in two phases. In Phase I, question items were developed based on the literature review and the preliminary psychometric properties of the inventory were evaluated using exploratory factor analysis. Phase II was conducted to evaluate the reliability and validity of the finalized inventory using confirmatory factor analysis. The results of exploratory and confirmatory factor analyses revealed the instrument was composed of seven factors, named course arrangement, equipment resource, debriefing, clinical ability, problem-solving, confidence and collaboration. A further second-order analysis showed comparable fits between a three second-order factor (preparation, process and outcome) and the seven first-order factor models. Internal consistency was supported by adequate Cronbach's alphas and composite reliability. Convergent and discriminant validities were also supported by confirmatory factor analysis. The study provides evidence that the Simulation Learning Effectiveness Inventory is reliable and valid for measuring student perception of learning effectiveness. The instrument is helpful in building the evidence-based knowledge of the effect of simulation teaching on students' learning outcomes. © 2015 John Wiley & Sons Ltd.

  9. A measurement tool to assess culture change regarding patient safety in hospital obstetrical units.

    PubMed

    Kenneth Milne, J; Bendaly, Nicole; Bendaly, Leslie; Worsley, Jill; FitzGerald, John; Nisker, Jeff

    2010-06-01

    Clinical error in acute care hospitals can only be addressed by developing a culture of safety. We sought to develop a cultural assessment survey (CAS) to assess patient safety culture change in obstetrical units. Interview prompts and a preliminary questionnaire were developed through a literature review of patient safety and "high reliability organizations," followed by interviews with members of the Managing Obstetrical Risk Efficiently (MOREOB) Program of the Society of Obstetricians and Gynaecologists of Canada. Three hundred preliminary questionnaires were mailed, and 21 interviews and 9 focus groups were conducted with the staff of 11 hospital sites participating in the program. To pilot test the CAS, 350 surveys were mailed to staff in participating hospitals, and interviews were conducted with seven nurses and five physicians who had completed the survey. Reliability analysis was conducted on four units that completed the CAS prior to and following the implementation of the first MOREOB module. Nineteen values and 105 behaviours, practices, and perceptions relating to patient safety were identified and included in the preliminary questionnaire, of which 143 of 300 (47.4%) were returned. Among the 220 cultural assessment surveys returned (62.9%), six cultural scales emerged: (1) patient safety as everyone's priority; (2) teamwork; (3) valuing individuals; (4) open communication; (5) learning; and (6) empowering individuals. The reliability analysis found all six scales to have internal reliability (Cronbach alpha), ranging from 0.72 (open communication) to 0.84 (valuing individuals). The CAS developed for this study may enable obstetrical units to assess change in patient safety culture.

  10. Evaluation of the reliability and accuracy of using cone-beam computed tomography for diagnosing periapical cysts from granulomas.

    PubMed

    Guo, Jing; Simon, James H; Sedghizadeh, Parish; Soliman, Osman N; Chapman, Travis; Enciso, Reyes

    2013-12-01

    The purpose of this study was to evaluate the reliability and accuracy of cone-beam computed tomographic (CBCT) imaging against the histopathologic diagnosis for the differential diagnosis of periapical cysts (cavitated lesions) from (solid) granulomas. Thirty-six periapical lesions were imaged using CBCT scans. Apicoectomy surgeries were conducted for histopathological examination. Evaluator 1 examined each CBCT scan for the presence of 6 radiologic characteristics of a cyst (ie, location, periphery, shape, internal structure, effects on surrounding structure, and perforation of the cortical plate). Not every cyst showed all radiologic features (eg, not all cysts perforate the cortical plate). For the purpose of finding the minimum number of diagnostic criteria present in a scan to diagnose a lesion as a cyst, we conducted 6 receiver operating characteristic curve analyses comparing CBCT diagnoses with the histopathologic diagnosis. Two other independent evaluators examined the CBCT lesions. Statistical tests were conducted to examine the accuracy, inter-rater reliability, and intrarater reliability of CBCT images. Findings showed that a score of ≥4 positive findings was the optimal scoring system. The accuracies of differential diagnoses of 3 evaluators were moderate (area under the curve = 0.76, 0.70, and 0.69 for evaluators 1, 2, and 3, respectively). The inter-rater agreement of the 3 evaluators was excellent (α = 0.87). The intrarater agreement was good to excellent (κ = 0.71, 0.76, and 0.77). CBCT images can provide a moderately accurate diagnosis between cysts and granulomas. Copyright © 2013 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  11. Test-retest reliability and predictors of unreliable reporting for a sexual behavior questionnaire for U.S. men.

    PubMed

    Nyitray, Alan G; Harris, Robin B; Abalos, Andrew T; Nielson, Carrie M; Papenfuss, Mary; Giuliano, Anna R

    2010-12-01

    Accurate knowledge about human sexual behaviors is important for increasing our understanding of human sexuality; however, there have been few studies assessing the reliability of sexual behavior questionnaires designed for community samples of adult men. A test-retest reliability study was conducted on a questionnaire completed by 334 men who had been recruited in Tucson, Arizona. Reliability coefficients and refusal rates were calculated for 39 non-sexual and sexual behavior questionnaire items. Predictors of unreliable reporting for lifetime number of female sexual partners were also assessed. Refusal rates were generally low, with slightly higher refusal rates for questions related to immigration, income, the frequency of sexual intercourse with women, lifetime number of female sexual partners, and the lifetime number of male anal sex partners. Kappa and intraclass correlation coefficients were substantial or almost perfect for all non-sexual and sexual behavior items. Reliability dropped somewhat, but was still substantial, for items that asked about household income and the men's knowledge of their sexual partners' health, including abnormal Pap tests and prior sexually transmitted diseases (STD). Age and lifetime number of female sexual partners were independent predictors of unreliable reporting while years of education was inversely associated with unreliable reporting. These findings among a community sample of adult men are consistent with other test-retest reliability studies with populations of women and adolescents.

  12. A proposed method to investigate reliability throughout a questionnaire

    PubMed Central

    2011-01-01

    Background Questionnaires are used extensively in medical and health care research and depend on validity and reliability. However, participants may differ in interest and awareness throughout long questionnaires, which can affect reliability of their answers. A method is proposed for "screening" of systematic change in random error, which could assess changed reliability of answers. Methods A simulation study was conducted to explore whether systematic change in reliability, expressed as changed random error, could be assessed using unsupervised classification of subjects by cluster analysis (CA) and estimation of intraclass correlation coefficient (ICC). The method was also applied on a clinical dataset from 753 cardiac patients using the Jalowiec Coping Scale. Results The simulation study showed a relationship between the systematic change in random error throughout a questionnaire and the slope between the estimated ICC for subjects classified by CA and successive items in a questionnaire. This slope was proposed as an awareness measure - to assessing if respondents provide only a random answer or one based on a substantial cognitive effort. Scales from different factor structures of Jalowiec Coping Scale had different effect on this awareness measure. Conclusions Even though assumptions in the simulation study might be limited compared to real datasets, the approach is promising for assessing systematic change in reliability throughout long questionnaires. Results from a clinical dataset indicated that the awareness measure differed between scales. PMID:21974842

  13. Discharge reliability in ablative pulsed plasma thrusters

    NASA Astrophysics Data System (ADS)

    Wu, Zhiwen; Sun, Guorui; Yuan, Shiyue; Huang, Tiankun; Liu, Xiangyang; Xie, Kan; Wang, Ningfei

    2017-08-01

    Discharge reliability is typically neglected in low-ignition-cycle ablative pulsed plasma thrusters (APPTs). In this study, the discharge reliability of an APPT is assessed analytically and experimentally. The goals of this study are to better understand the ignition characteristics and to assess the accuracy of the analytical method. For each of six sets of operating conditions, 500 tests of a parallel-plate APPT with a coaxial semiconductor spark plug are conducted. The discharge voltage and current are measured with a high-voltage probe and a Rogowski coil, respectively, to determine whether the discharge is successful. Generally, the discharge success rate increases as the discharge voltage increases, and it decreases as the electrode gap and the number of ignitions increases. The theoretical analysis and the experimental results are reasonably consistent. This approach provides a reference for designing APPTs and improving their stability.

  14. The Transition Readiness Assessment Questionnaire (TRAQ): its factor structure, reliability, and validity.

    PubMed

    Wood, David L; Sawicki, Gregory S; Miller, M David; Smotherman, Carmen; Lukens-Bull, Katryne; Livingood, William C; Ferris, Maria; Kraemer, Dale F

    2014-01-01

    National consensus statements recommend that providers regularly assess the transition readiness skills of adolescent and young adults (AYA). In 2010 we developed a 29-item version of Transition Readiness Assessment Questionnaire (TRAQ). We reevaluated item performance and factor structure, and reassessed the TRAQ's reliability and validity. We surveyed youth from 3 academic clinics in Jacksonville, Florida; Chapel Hill, North Carolina; and Boston, Massachusetts. Participants were AYA with special health care needs aged 14 to 21 years. From a convenience sample of 306 patients, we conducted item reduction strategies and exploratory factor analysis (EFA). On a second convenience sample of 221 patients, we conducted confirmatory factor analysis (CFA). Internal reliability was assessed by Cronbach's alpha and criterion validity. Analyses were conducted by the Wilcoxon rank sum test and mixed linear models. The item reduction and EFA resulted in a 20-item scale with 5 identified subscales. The CFA conducted on a second sample provided a good fit to the data. The overall scale has high reliability overall (Cronbach's alpha = .94) and good reliability for 4 of the 5 subscales (Cronbach's alpha ranging from .90 to .77 in the pooled sample). Each of the 5 subscale scores were significantly higher for adolescents aged 18 years and older versus those younger than 18 (P < .0001) in both univariate and multivariate analyses. The 20-item, 5-factor structure for the TRAQ is supported by EFA and CFA on independent samples and has good internal reliability and criterion validity. Additional work is needed to expand or revise the TRAQ subscales and test their predictive validity. Copyright © 2014 Academic Pediatric Association. Published by Elsevier Inc. All rights reserved.

  15. Reliability Studies of Ceramic Capacitors.

    DTIC Science & Technology

    1984-10-01

    Virginia Polytechnic BaTiO 3 Ispecimens with variable composition, density and grain size to be used to make carrier concentration, mobility, thermoelectric ...low fields, observed steady-state electrical behavior will be controlled by the bulk properties of the insulator, the second phase of the conduction...carrier mobility E =applied field Note that bulk properties of the Insulator control the conduction process. From this equation it can be seen that a

  16. Can gastritis symptoms be evaluated in clinical trials? An overview of treatment of gastritis, nonulcer dyspepsia and Campylobacter-associated gastritis.

    PubMed

    Veldhuyzen van Zanten, S J; Tytgat, K M; Jalali, S; Goodacre, R L; Hunt, R H

    1989-10-01

    We carried out a review of the literature on Campylobacter pylori-associated gastritis and nonulcer dyspepsia (NUD) to determine whether or not symptoms related to these conditions can be measured reliably and whether or not any study to date has shown that treatment alters symptoms. Search strategies consisted of online Medline searching, a forward search of three articles using the Science Citation Index, a manual search of five gastroenterological journals, and a fully recursive search of cited references. Inclusion and quality criteria were applied to all retrieved studies. Nine of 23 studies did not fulfill the inclusion criteria. Of the 14 studies analyzed, two measured symptoms reliably. Neither showed a therapeutic benefit on symptoms. The difficulties encountered in conducting such studies and the methods of recording symptoms reliably are discussed. We conclude that to date, no treatment is of proven benefit in the relief of symptoms associated with C. pylori gastritis and NUD.

  17. Validity and reliability of criterion based clinical audit to assess obstetrical quality of care in West Africa.

    PubMed

    Pirkle, Catherine M; Dumont, Alexandre; Traore, Mamadou; Zunzunegui, Maria-Victoria

    2012-10-29

    In Mali and Senegal, over 1% of women die giving birth in hospital. At some hospitals, over a third of infants are stillborn. Many deaths are due to substandard medical practices. Criterion-based clinical audits (CBCA) are increasingly used to measure and improve obstetrical care in resource-limited settings, but their measurement properties have not been formally evaluated. In 2011, we published a systematic review of obstetrical CBCA highlighting insufficient considerations of validity and reliability. The objective of this study is to develop an obstetrical CBCA adapted to the West African context and assess its reliability and validity. This work was conducted as a sub-study within a cluster randomized trial known as QUARITE. Criteria were selected based on extensive literature review and expert opinion. Early 2010, two auditors applied the CBCA to identical samples at 8 sites in Mali and Senegal (n = 185) to evaluate inter-rater reliability. In 2010-11, we conducted CBCA at 32 hospitals to assess construct validity (n = 633 patients). We correlated hospital characteristics (resource availability, facility perinatal and maternal mortality) with mean hospital CBCA scores. We used generalized estimating equations to assess whether patient CBCA scores were associated with perinatal mortality. Results demonstrate substantial (ICC = 0.67, 95% CI 0.54; 0.76) to elevated inter-rater reliability (ICC = 0.84, 95% CI 0.77; 0.89) in Senegal and Mali, respectively. Resource availability positively correlated with mean hospital CBCA scores and maternal and perinatal mortality were inversely correlated with hospital CBCA scores. Poor CBCA scores, adjusted for hospital and patient characteristics, were significantly associated with perinatal mortality (OR 1.84, 95% CI 1.01-3.34). Our CBCA has substantial inter-rater reliability and there is compelling evidence of its validity as the tool performs according to theory. Current Controlled Trials ISRCTN46950658.

  18. The probability estimation of the electronic lesson implementation taking into account software reliability

    NASA Astrophysics Data System (ADS)

    Gurov, V. V.

    2017-01-01

    Software tools for educational purposes, such as e-lessons, computer-based testing system, from the point of view of reliability, have a number of features. The main ones among them are the need to ensure a sufficiently high probability of their faultless operation for a specified time, as well as the impossibility of their rapid recovery by the way of replacing it with a similar running program during the classes. The article considers the peculiarities of reliability evaluation of programs in contrast to assessments of hardware reliability. The basic requirements to reliability of software used for carrying out practical and laboratory classes in the form of computer-based training programs are given. The essential requirements applicable to the reliability of software used for conducting the practical and laboratory studies in the form of computer-based teaching programs are also described. The mathematical tool based on Markov chains, which allows to determine the degree of debugging of the training program for use in the educational process by means of applying the graph of the software modules interaction, is presented.

  19. Viscosity and thermal conductivity coefficients of gaseous and liquid oxygen

    NASA Technical Reports Server (NTRS)

    Hanley, H. J. M.; Mccarty, R. D.; Sengers, J. V.

    1974-01-01

    Equations and tables are presented for the viscosity and thermal conductivity coefficients of gaseous and liquid oxygen at temperatures between 80 K and 400 K for pressures up to 200 atm. and at temperatures between 80 K and 2000 K for the dilute gas. A description of the anomalous behavior of the thermal conductivity in the critical region is included. The tabulated coefficients are reliable to within about 15% except for a region in the immediate vicinity of the critical point. Some possibilities for future improvements of this reliability are discussed.

  20. Standard operation procedures for conducting the on-the-road driving test, and measurement of the standard deviation of lateral position (SDLP)

    PubMed Central

    Verster, Joris C; Roth, Thomas

    2011-01-01

    This review discusses the methodology of the standardized on-the-road driving test and standard operation procedures to conduct the test and analyze the data. The on-the-road driving test has proven to be a sensitive and reliable method to examine driving ability after administration of central nervous system (CNS) drugs. The test is performed on a public highway in normal traffic. Subjects are instructed to drive with a steady lateral position and constant speed. Its primary parameter, the standard deviation of lateral position (SDLP), ie, an index of ‘weaving’, is a stable measure of driving performance with high test–retest reliability. SDLP differences from placebo are dose-dependent, and do not depend on the subject’s baseline driving skills (placebo SDLP). It is important that standard operation procedures are applied to conduct the test and analyze the data in order to allow comparisons between studies from different sites. PMID:21625472

  1. Standard operation procedures for conducting the on-the-road driving test, and measurement of the standard deviation of lateral position (SDLP).

    PubMed

    Verster, Joris C; Roth, Thomas

    2011-01-01

    This review discusses the methodology of the standardized on-the-road driving test and standard operation procedures to conduct the test and analyze the data. The on-the-road driving test has proven to be a sensitive and reliable method to examine driving ability after administration of central nervous system (CNS) drugs. The test is performed on a public highway in normal traffic. Subjects are instructed to drive with a steady lateral position and constant speed. Its primary parameter, the standard deviation of lateral position (SDLP), ie, an index of 'weaving', is a stable measure of driving performance with high test-retest reliability. SDLP differences from placebo are dose-dependent, and do not depend on the subject's baseline driving skills (placebo SDLP). It is important that standard operation procedures are applied to conduct the test and analyze the data in order to allow comparisons between studies from different sites.

  2. Reliability and validity: Part II.

    PubMed

    Davis, Debora Winders

    2004-01-01

    Determining measurement reliability and validity involves complex processes. There is usually room for argument about most instruments. It is important that the researcher clearly describes the processes upon which she made the decision to use a particular instrument, and presents the evidence available showing that the instrument is reliable and valid for the current purposes. In some cases, the researcher may need to conduct pilot studies to obtain evidence upon which to decide whether the instrument is valid for a new population or a different setting. In all cases, the researcher must present a clear and complete explanation for the choices, she has made regarding reliability and validity. The consumer must then judge the degree to which the researcher has provided adequate and theoretically sound rationale. Although I have tried to touch on most of the important concepts related to measurement reliability and validity, it is beyond the scope of this column to be exhaustive. There are textbooks devoted entirely to specific measurement issues if readers require more in-depth knowledge.

  3. Dynamic MRI to quantify musculoskeletal motion: A systematic review of concurrent validity and reliability, and perspectives for evaluation of musculoskeletal disorders.

    PubMed

    Borotikar, Bhushan; Lempereur, Mathieu; Lelievre, Mathieu; Burdin, Valérie; Ben Salem, Douraied; Brochard, Sylvain

    2017-01-01

    To report evidence for the concurrent validity and reliability of dynamic MRI techniques to evaluate in vivo joint and muscle mechanics, and to propose recommendations for their use in the assessment of normal and impaired musculoskeletal function. The search was conducted on articles published in Web of science, PubMed, Scopus, Academic search Premier, and Cochrane Library between 1990 and August 2017. Studies that reported the concurrent validity and/or reliability of dynamic MRI techniques for in vivo evaluation of joint or muscle mechanics were included after assessment by two independent reviewers. Selected articles were assessed using an adapted quality assessment tool and a data extraction process. Results for concurrent validity and reliability were categorized as poor, moderate, or excellent. Twenty articles fulfilled the inclusion criteria with a mean quality assessment score of 66% (±10.4%). Concurrent validity and/or reliability of eight dynamic MRI techniques were reported, with the knee being the most evaluated joint (seven studies). Moderate to excellent concurrent validity and reliability were reported for seven out of eight dynamic MRI techniques. Cine phase contrast and real-time MRI appeared to be the most valid and reliable techniques to evaluate joint motion, and spin tag for muscle motion. Dynamic MRI techniques are promising for the in vivo evaluation of musculoskeletal mechanics; however results should be evaluated with caution since validity and reliability have not been determined for all joints and muscles, nor for many pathological conditions.

  4. Impact of Rating Scale Categories on Reliability and Fit Statistics of the Malay Spiritual Well-Being Scale using Rasch Analysis.

    PubMed

    Daher, Aqil Mohammad; Ahmad, Syed Hassan; Winn, Than; Selamat, Mohd Ikhsan

    2015-01-01

    Few studies have employed the item response theory in examining reliability. We conducted this study to examine the effect of Rating Scale Categories (RSCs) on the reliability and fit statistics of the Malay Spiritual Well-Being Scale, employing the Rasch model. The Malay Spiritual Well-Being Scale (SWBS) with the original six; three and four newly structured RSCs was distributed randomly among three different samples of 50 participants each. The mean age of respondents in the three samples ranged between 36 and 39 years old. The majority was female in all samples, and Islam was the most prevalent religion among the respondents. The predominating race was Malay, followed by Chinese and Indian. The original six RSCs indicated better targeting of 0.99 and smallest model error of 0.24. The Infit Mnsq (mean square) and Zstd (Z standard) of the six RSCs were "1.1"and "-0.1"respectively. The six RSCs achieved the highest person and item reliabilities of 0.86 and 0.85 respectively. These reliabilities yielded the highest person (2.46) and item (2.38) separation indices compared to other the RSCs. The person and item reliability and, to a lesser extent, the fit statistics, were better with the six RSCs compared to the four and three RSCs.

  5. Inter- and intra- observer reliability of risk assessment of repetitive work without an explicit method.

    PubMed

    Eliasson, Kristina; Palm, Peter; Nyman, Teresia; Forsman, Mikael

    2017-07-01

    A common way to conduct practical risk assessments is to observe a job and report the observed long term risks for musculoskeletal disorders. The aim of this study was to evaluate the inter- and intra-observer reliability of ergonomists' risk assessments without the support of an explicit risk assessment method. Twenty-one experienced ergonomists assessed the risk level (low, moderate, high risk) of eight upper body regions, as well as the global risk of 10 video recorded work tasks. Intra-observer reliability was assessed by having nine of the ergonomists repeat the procedure at least three weeks after the first assessment. The ergonomists made their risk assessment based on his/her experience and knowledge. The statistical parameters of reliability included agreement in %, kappa, linearly weighted kappa, intraclass correlation and Kendall's coefficient of concordance. The average inter-observer agreement of the global risk was 53% and the corresponding weighted kappa (K w ) was 0.32, indicating fair reliability. The intra-observer agreement was 61% and 0.41 (K w ). This study indicates that risk assessments of the upper body, without the use of an explicit observational method, have non-acceptable reliability. It is therefore recommended to use systematic risk assessment methods to a higher degree. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  6. Test-retest reliability of the safe driving behavior measure for community-dwelling elderly drivers.

    PubMed

    Song, Chiang-Soon; Lee, Joo-Hyun; Han, Sang-Woo

    2016-06-01

    [Purpose] The Safe Driving Behavior Measure (SDBM) is a self-report measurement tools that assesses the safe-driving behaviors of the elderly. The purpose of this study was to evaluate the test-retest reliability of the SDBM among community-dwelling elderly drivers. [Subjects and Methods] A total of sixty-one community-dwelling elderly were enrolled to investigate the reliability of the SDBM. The SDBM was assessed in two sessions that were conducted three days apart in a quiet and well-organized assessment room. That test-retest reliability of overall scores and three domain scores of the SDBM were statistically evaluated using intraclass correlation coefficients [ICC (2.1)]. Pearson correlation coefficients were used to quantify bivariate associations among the three domains of the SDBM. [Results] The SDBM demonstrated excellent rest-retest reliability for community-dwelling elderly drivers. The Cronbach alpha coefficients of the three domains of person-vehicle (0.979), person-environment (0.944), and person-vehicle-environment (0.971) of the SDBM indicate high internal consistency. [Conclusion] The results of this study suggest that the SDBM is a reliable measure for evaluating the safe- driving of automobiles by community-dwelling elderly, and is adequate for detecting changes in scores in clinical settings.

  7. Contraceptive knowledge, attitudes, and practice in Russia during the 1980s.

    PubMed

    Popov, A A; Visser, A P; Ketting, E

    1993-01-01

    In the former Soviet Union, there was a lack of valid and reliable social research on knowledge, attitudes, and practice of contraception. The few available studies have not been published outside the Soviet Union. This article reviews five surveys that were conducted in Moscow and two other cities (Saratov and Tartu) during the period 1976-84. In addition, some data from a large-scale survey conducted in 1990 and covering the entire former Soviet Union are presented. The surveys indicate that the rhythm method, condoms, vaginal douches, and withdrawal were the main contraceptive methods used; only 1 to 3 percent of the women interviewed were using oral contraceptives, and about 10 percent used intrauterine devices. The low prevalence of use of reliable modern methods may explain the high incidence of induced abortion in Russia. The chronic unavailability of reliable contraceptives is one of the main factors of poor family planning. Lack of knowledge and negative opinions about modern contraception also play an important role. Some possibilities for improving the family planning situation in Russia are discussed.

  8. Reliability and the adaptive utility of discrimination among alarm callers.

    PubMed

    Blumstein, Daniel T; Verneyre, Laure; Daniel, Janice C

    2004-09-07

    Unlike individually distinctive contact calls, or calls that aid in the recognition of young by their parents, the function or functions of individually distinctive alarm calls is less obvious. We conducted three experiments to study the importance of caller reliability in explaining individual-discriminative abilities in the alarm calls of yellow-bellied marmots (Marmota flaviventris). In our first two experiments, we found that calls from less reliable individuals and calls from individuals calling from a greater simulated distance were more evocative than calls from reliable individuals or nearby callers. These results are consistent with the hypothesis that marmots assess the reliability of callers to help them decide how much time to allocate to independent vigilance. The third experiment demonstrated that the number of callers influenced responsiveness, probably because situations where more than a single caller calls, are those when there is certain to be a predator present. Taken together, the results from all three experiments demonstrate the importance of reliability in explaining individual discrimination abilities in yellow-bellied marmots. Marmots' assessment of reliability acts by influencing the time allocated to individual assessment and thus the time not allocated to other activities.

  9. Reliability and the adaptive utility of discrimination among alarm callers.

    PubMed Central

    Blumstein, Daniel T.; Verneyre, Laure; Daniel, Janice C.

    2004-01-01

    Unlike individually distinctive contact calls, or calls that aid in the recognition of young by their parents, the function or functions of individually distinctive alarm calls is less obvious. We conducted three experiments to study the importance of caller reliability in explaining individual-discriminative abilities in the alarm calls of yellow-bellied marmots (Marmota flaviventris). In our first two experiments, we found that calls from less reliable individuals and calls from individuals calling from a greater simulated distance were more evocative than calls from reliable individuals or nearby callers. These results are consistent with the hypothesis that marmots assess the reliability of callers to help them decide how much time to allocate to independent vigilance. The third experiment demonstrated that the number of callers influenced responsiveness, probably because situations where more than a single caller calls, are those when there is certain to be a predator present. Taken together, the results from all three experiments demonstrate the importance of reliability in explaining individual discrimination abilities in yellow-bellied marmots. Marmots' assessment of reliability acts by influencing the time allocated to individual assessment and thus the time not allocated to other activities. PMID:15315902

  10. [Evaluation of Suicide Risk Levels in Hospitals: Validity and Reliability Tests].

    PubMed

    Macagnino, Sandro; Steinert, Tilman; Uhlmann, Carmen

    2018-05-01

    Examination of in-hospital suicide risk levels concerning their validity and their reliability. The internal suicide risk levels were evaluated in a cross sectional study of in 163 inpatients. A reliability check was performed via determining interrater-reliability of senior physician, therapist and the responsible nurse. Within the scope of the validity check, we conducted analyses of criterion validity and construct validity. For the total sample an "acceptable" to "good" interrater-reliability (Kendalls W = .77) of suicide risk levels were obtained. Schizophrenic disorders showed the lowest values, for personality disorders we found the highest level of interrater-reliability. When examining the criterion validity, Item-9 of the BDI-II is substantial correlated to our suicide risk levels (ρ m  = .54, p < .01). Within the scope of construct validity check, affective disorders showed the highest correlation (ρ = .77), compatible also with "convergent validity". They differed with schizophrenic disorders which showed the least concordance (ρ = .43). In-hospital suicide risk levels may represent an important contribution to the assessment of suicidal behavior of inpatients experiencing psychiatric treatment due to their overall good validity and reliability. © Georg Thieme Verlag KG Stuttgart · New York.

  11. Test-retest reliability of the KINARM end-point robot for assessment of sensory, motor and neurocognitive function in young adult athletes.

    PubMed

    Mang, Cameron S; Whitten, Tara A; Cosh, Madeline S; Scott, Stephen H; Wiley, J Preston; Debert, Chantel T; Dukelow, Sean P; Benson, Brian W

    2018-01-01

    Current assessment tools for sport-related concussion are limited by a reliance on subjective interpretation and patient symptom reporting. Robotic assessments may provide more objective and precise measures of neurological function than traditional clinical tests. To determine the reliability of assessments of sensory, motor and cognitive function conducted with the KINARM end-point robotic device in young adult elite athletes. Sixty-four randomly selected healthy, young adult elite athletes participated. Twenty-five individuals (25 M, mean age±SD, 20.2±2.1 years) participated in a within-season study, where three assessments were conducted within a single season (assessments labeled by session: S1, S2, S3). An additional 39 individuals (28M; 22.8±6.0 years) participated in a year-to-year study, where annual pre-season assessments were conducted for three consecutive seasons (assessments labeled by year: Y1, Y2, Y3). Forty-four parameters from five robotic tasks (Visually Guided Reaching, Position Matching, Object Hit, Object Hit and Avoid, and Trail Making B) and overall Task Scores describing performance on each task were quantified. Test-retest reliability was determined by intra-class correlation coefficients (ICCs) between the first and second, and second and third assessments. In the within-season study, ICCs were ≥0.50 for 68% of parameters between S1 and S2, 80% of parameters between S2 and S3, and for three of the five Task Scores both between S1 and S2, and S2 and S3. In the year-to-year study, ICCs were ≥0.50 for 64% of parameters between Y1 and Y2, 82% of parameters between Y2 and Y3, and for four of the five Task Scores both between Y1 and Y2, and Y2 and Y3. Overall, the results suggest moderate-to-good test-retest reliability for the majority of parameters measured by the KINARM robot in healthy young adult elite athletes. Future work will consider the potential use of this information for clinical assessment of concussion-related neurological deficits.

  12. Validity and reliability of bilingual English-Arabic version of Schutte self report emotional intelligence scale in an undergraduate Arab medical student sample.

    PubMed

    Naeem, Naghma; Muijtjens, Arno

    2015-04-01

    The psychological construct of emotional intelligence (EI), its theoretical models, measurement instruments and applications have been the subject of several research studies in health professions education. The objective of the current study was to investigate the factorial validity and reliability of a bilingual version of the Schutte Self Report Emotional Intelligence Scale (SSREIS) in an undergraduate Arab medical student population. The study was conducted during April-May 2012. A cross-sectional survey design was employed. A sample (n = 467) was obtained from undergraduate medical students belonging to the male and female medical college of King Saud University, Riyadh, Saudi Arabia. Exploratory and confirmatory factor analysis was performed using SPSS 16.0 and AMOS 4.0 statistical software to determine the factor structure. Reliability was determined using Cronbach's alpha statistics. The results obtained using an undergraduate Arab medical student sample supported a multidimensional; three factor structure of the SSREIS. The three factors are Optimism, Awareness-of-Emotions and Use-of-Emotions. The reliability (Cronbach's alpha) for the three subscales was 0.76, 0.72 and 0.55, respectively. Emotional intelligence is a multifactorial construct (three factors). The bilingual version of the SSREIS is a valid and reliable measure of trait emotional intelligence in an undergraduate Arab medical student population.

  13. Is a sphygmomanometer a valid and reliable tool to measure the isometric strength of hip muscles? A systematic review.

    PubMed

    Toohey, Liam Anthony; De Noronha, Marcos; Taylor, Carolyn; Thomas, James

    2015-02-01

    Muscle strength measurement is a key component of physiotherapists' assessment and is frequently used as an outcome measure. A sphygmomanometer is an instrument commonly used to measure blood pressure that can be potentially used as a tool to assess isometric muscle strength. To systematically review the evidence on the reliability and validity of a sphygmomanometer for measuring isometric strength of hip muscles. A literature search was conducted across four databases. Studies were eligible if they presented data on reliability and/or validity, used a sphygmomanometer to measure isometric muscle strength of the hip region, and were peer reviewed. The individual studies were evaluated for quality using a standardized critical appraisal tool. A total of 644 articles were screened for eligibility, with five articles chosen for inclusion. The use of a sphygmomanometer to objectively assess isometric muscle strength of the hip muscles appears to be reliable with intraclass correlation coefficient values ranging from 0.66 to 0.94 in elderly and young populations. No studies were identified that have assessed the validity of a sphygmomanometer. The sphygmomanometer appears to be reliable for assessment of isometric muscle strength around the hip joint, but further research is warranted to establish its validity.

  14. Development of the Nonverbal Communication Skills of School Administrators Scale (NCSSAS): Validity, Reliability and Implementation Study

    ERIC Educational Resources Information Center

    Uzun, Tevfik

    2017-01-01

    The main purpose of this study is to develop a scale intended for identifying the school administrators' nonverbal communication skills, and establish the relationship between the nonverbal communication skills of school administrators and job performance of teachers. The study was conducted in three stages. The first stage involved the creation…

  15. Hypertension Knowledge-Level Scale (HK-LS): a study on development, validity and reliability.

    PubMed

    Erkoc, Sultan Baliz; Isikli, Burhanettin; Metintas, Selma; Kalyoncu, Cemalettin

    2012-03-01

    This study was conducted to develop a scale to measure knowledge about hypertension among Turkish adults. The Hypertension Knowledge-Level Scale (HK-LS) was generated based on content, face, and construct validity, internal consistency, test re-test reliability, and discriminative validity procedures. The final scale had 22 items with six sub-dimensions. The scale was applied to 457 individuals aged ≥ 18 years, and 414 of them were re-evaluated for test-retest reliability. The six sub-dimensions encompassed 60.3% of the total variance. Cronbach alpha coefficients were 0.82 for the entire scale and 0.92, 0.59, 0.67, 0.77, 0.72, and 0.76 for the sub-dimensions of definition, medical treatment, drug compliance, lifestyle, diet, and complications, respectively. The scale ensured internal consistency in reliability and construct validity, as well as stability over time. Significant relationships were found between knowledge score and age, gender, educational level, and history of hypertension of the participants. No correlation was found between knowledge score and working at an income-generating job. The present scale, developed to measure the knowledge level of hypertension among Turkish adults, was found to be valid and reliable.

  16. Learning Style Scales: a valid and reliable questionnaire.

    PubMed

    Abdollahimohammad, Abdolghani; Ja'afar, Rogayah

    2014-01-01

    Learning-style instruments assist students in developing their own learning strategies and outcomes, in eliminating learning barriers, and in acknowledging peer diversity. Only a few psychometrically validated learning-style instruments are available. This study aimed to develop a valid and reliable learning-style instrument for nursing students. A cross-sectional survey study was conducted in two nursing schools in two countries. A purposive sample of 156 undergraduate nursing students participated in the study. Face and content validity was obtained from an expert panel. The LSS construct was established using principal axis factoring (PAF) with oblimin rotation, a scree plot test, and parallel analysis (PA). The reliability of LSS was tested using Cronbach's α, corrected item-total correlation, and test-retest. Factor analysis revealed five components, confirmed by PA and a relatively clear curve on the scree plot. Component strength and interpretability were also confirmed. The factors were labeled as perceptive, solitary, analytic, competitive, and imaginative learning styles. Cronbach's α was >0.70 for all subscales in both study populations. The corrected item-total correlations were >0.30 for the items in each component. The LSS is a valid and reliable inventory for evaluating learning style preferences in nursing students in various multicultural environments.

  17. Reliability of the ECHOWS Tool for Assessment of Patient Interviewing Skills.

    PubMed

    Boissonnault, Jill S; Evans, Kerrie; Tuttle, Neil; Hetzel, Scott J; Boissonnault, William G

    2016-04-01

    History taking is an important component of patient/client management. Assessment of student history-taking competency can be achieved via a standardized tool. The ECHOWS tool has been shown to be valid with modest intrarater reliability in a previous study but did not demonstrate sufficient power to definitively prove its stability. The purposes of this study were: (1) to assess the reliability of the ECHOWS tool for student assessment of patient interviewing skills and (2) to determine whether the tool discerns between novice and experienced skill levels. A reliability and construct validity assessment was conducted. Three faculty members from the United States and Australia scored videotaped histories from standardized patients taken by students and experienced clinicians from each of these countries. The tapes were scored twice, 3 to 6 weeks apart. Reliability was assessed using interclass correlation coefficients (ICCs) and repeated measures. Analysis of variance models assessed the ability of the tool to discern between novice and experienced skill levels. The ECHOWS tool showed excellent intrarater reliability (ICC [3,1]=.74-.89) and good interrater reliability (ICC [2,1]=.55) as a whole. The summary of performance (S) section showed poor interrater reliability (ICC [2,1]=.27). There was no statistical difference in performance on the tool between novice and experienced clinicians. A possible ceiling effect may occur when standardized patients are not coached to provide complex and obtuse responses to interviewer questions. Variation in familiarity with the ECHOWS tool and in use of the online training may have influenced scoring of the S section. The ECHOWS tool demonstrates excellent intrarater reliability and moderate interrater reliability. Sufficient training with the tool prior to student assessment is recommended. The S section must evolve in order to provide a more discerning measure of interviewing skills. © 2016 American Physical Therapy Association.

  18. Demonstrating the Safety and Reliability of a New System or Spacecraft: Incorporating Analyses and Reviews of the Design and Processing in Determining the Number of Tests to be Conducted

    NASA Technical Reports Server (NTRS)

    Vesely, William E.; Colon, Alfredo E.

    2010-01-01

    Design Safety/Reliability is associated with the probability of no failure-causing faults existing in a design. Confidence in the non-existence of failure-causing faults is increased by performing tests with no failure. Reliability-Growth testing requirements are based on initial assurance and fault detection probability. Using binomial tables generally gives too many required tests compared to reliability-growth requirements. Reliability-Growth testing requirements are based on reliability principles and factors and should be used.

  19. Computer calculation of device, circuit, equipment, and system reliability.

    NASA Technical Reports Server (NTRS)

    Crosby, D. R.

    1972-01-01

    A grouping into four classes is proposed for all reliability computations that are related to electronic equipment. Examples are presented of reliability computations in three of these four classes. Each of the three specific reliability tasks described was originally undertaken to satisfy an engineering need for reliability data. The form and interpretation of the print-out of the specific reliability computations is presented. The justification for the costs of these computations is indicated. The skills of the personnel used to conduct the analysis, the interfaces between the personnel, and the timing of the projects is discussed.

  20. Reliability of self-reported childhood physical abuse by adults and factors predictive of inconsistent reporting.

    PubMed

    McKinney, Christy M; Harris, T Robert; Caetano, Raul

    2009-01-01

    Little is known about the reliability of self-reported child physical abuse (CPA) or CPA reporting practices. We estimated reliability and prevalence of self-reported CPA and identified factors predictive of inconsistent CPA reporting among 2,256 participants using surveys administered in 1995 and 2000. Reliability of CPA was fair to moderate (kappa = 0.41). Using a positive report from either survey, the prevalence of moderate (61.8%) and severe (12.0%) CPA was higher than at either survey alone. Compared to consistent reporters of having experienced CPA, inconsistent reporters were less likely to be > or = 30 years old (vs. 18-29) or Black (vs. White) and more likely to have < 12 years of education (vs. 12), have no alcohol-related problems (vs. having problems), or report one type (vs. > or = 2) of CPA. These findings may assist researchers conducting and interpreting studies of CPA.

  1. Evaluating shallow-flow rock structures as scour countermeasures at bridges.

    DOT National Transportation Integrated Search

    2009-12-01

    A study to determine whether or not shallow-flow rock structures could reliably be used at bridge abutments in place of riprap. Research was conducted in a two-phase effort beginning with numerical modeling and ending with field verification of model...

  2. Efficiency tests of samplers for microbiological aerosols, a review

    NASA Technical Reports Server (NTRS)

    Henningson, E.; Faengmark, I.

    1984-01-01

    To obtain comparable results from studies using a variety of samplers of microbiological aerosols with different collection performances for various particle sizes, methods reported in the literature were surveyed, evaluated, and tabulated for testing the efficiency of the samplers. It is concluded that these samplers were not thoroughly tested, using reliable methods. Tests were conducted in static air chambers and in various outdoor and work environments. Results are not reliable as it is difficult to achieve stable and reproducible conditions in these test systems. Testing in a wind tunnel is recommended.

  3. Direct visualization and in-depth physical study of metal filament formation in percolated high-κ dielectrics

    NASA Astrophysics Data System (ADS)

    Li, X.; Pey, K. L.; Bosman, M.; Liu, W. H.; Kauerauf, T.

    2010-01-01

    The migration of Ta atoms from a transistor gate electrode into the percolated high-κ (HK) gate dielectrics is directly shown using transmission electron microscopy analysis. A nanoscale metal filament that formed under high current injection is identified to be the physical defect responsible for the ultrafast transient breakdown (BD) of the metal-gate/high-κ (MG/HK) gate stacks. This highly conductive metal filament poses reliability concerns for MG/HK gate stacks as it significantly reduces the post-BD reliability margin of a transistor.

  4. Development and Testing of a USM High Altitude Balloon

    NASA Astrophysics Data System (ADS)

    Thaheer, A. S. Mohamed; Ismail, N. A.; Yusoff, S. H. Md.; Nasirudin, M. A.

    2018-04-01

    This paper discusses on tests conducted on the component and subsystem level during development of the USM High Altitude Balloon (HAB). The tests conducted by selecting initial components then tested individually based on several case studies such as reliability test, camera viewing, power consumption, thermal capability, and parachute performance. Then, the component is integrated into sub-system level for integration and functionality test. The preliminary result is utilized to tune the components and sub-systems and trial launch is conducted where the sample images are recorded and atmospheric data successfully collected.

  5. Extralinguistic speech characteristics of children with conduct and anxiety disorders.

    PubMed

    Kotsopoulos, S; Mellor, C

    1986-01-01

    Nine children with conduct and nine with anxiety disorder participated in the study. The subjects were requested to respond to verbal tasks (counting, picture description, story telling). Disturbance of conduct was associated with short initial hesitation before speaking. It is suggested that the initial hesitation variables are measures of reflection and cognitive planning. Anxiety across subjects was associated with increased breath rate and lower output of speech per breath. It is suggested speech breath variables are reliable measures of anxiety. Implication for the diagnosis and management of child psychiatric disorders are discussed.

  6. Psychometric Properties of the Persian Language Version of Yang Internet Addiction Questionnaire: An Explanatory Factor Analysis.

    PubMed

    Mohammadsalehi, Narges; Mohammadbeigi, Abolfazl; Jadidi, Rahmatollah; Anbari, Zohreh; Ghaderi, Ebrahim; Akbari, Mojtaba

    2015-09-01

    Reliability and validity are the key concepts in measurement processes. Young internet addiction test (YIAT) is regarded as a valid and reliable questionnaire in English speaking countries for diagnosis of Internet-related behavior disorders. This study aimed at validating the Persian version of YIAT in the Iranian society. A pilot and a cross-sectional study were conducted on 28 and 254 students of Qom University of Medical Sciences, respectively, in order to validate the Persian version of YIAT. Forward and backward translations were conducted to develop a Persian version of the scale. Reliability was measured by test-retest, Cronbach's alpha and interclass correlation coefficient (ICC). Face, content and construct validity were approved by the importance score index, content validity ratio (CVR), content validity index (CVI), correlation matrix and factor analysis. The SPSS software was used for data analysis. The Cronbach's alpha was 0.917 (CI 95%; 0.901 - 0.931). The average of scale-level CVI was calculated to be 0.74; the CVI index for each item was higher than 0.83 and the average of CVI index was equal to 0.89. Factor analysis extracted three factors including personal activities disorder (PAD), emotional and mood disorder (EMD) and social activities disorder (SAD), with more than 55.8% of total variances. The ICC for different factors of Persian version of Young Questionnaire including PAD, EMD and for SAD was r = 0.884; CI 95%; 0.861 - 0.904, r = 0.766; CI 95%; 0.718 - 0.808 and r = 0.745; CI 95%; 0.686 - 0.795, respectively. Our study showed that the Persian version of YIAT is good and usable on Iranian people. The reliability of the instrument was very good. Moreover, the validity of the Persian translated version of the scale was sufficient. In addition, the reliability and validity of the three extracted factors of YIAT were evaluated and were acceptable.

  7. Psychometric Properties of the Persian Language Version of Yang Internet Addiction Questionnaire: An Explanatory Factor Analysis

    PubMed Central

    Mohammadsalehi, Narges; Mohammadbeigi, Abolfazl; Jadidi, Rahmatollah; Anbari, Zohreh; Ghaderi, Ebrahim; Akbari, Mojtaba

    2015-01-01

    Background: Reliability and validity are the key concepts in measurement processes. Young internet addiction test (YIAT) is regarded as a valid and reliable questionnaire in English speaking countries for diagnosis of Internet-related behavior disorders. Objectives: This study aimed at validating the Persian version of YIAT in the Iranian society. Patients and Methods: A pilot and a cross-sectional study were conducted on 28 and 254 students of Qom University of Medical Sciences, respectively, in order to validate the Persian version of YIAT. Forward and backward translations were conducted to develop a Persian version of the scale. Reliability was measured by test-retest, Cronbach’s alpha and interclass correlation coefficient (ICC). Face, content and construct validity were approved by the importance score index, content validity ratio (CVR), content validity index (CVI), correlation matrix and factor analysis. The SPSS software was used for data analysis. Results: The Cronbach’s alpha was 0.917 (CI 95%; 0.901 - 0.931). The average of scale-level CVI was calculated to be 0.74; the CVI index for each item was higher than 0.83 and the average of CVI index was equal to 0.89. Factor analysis extracted three factors including personal activities disorder (PAD), emotional and mood disorder (EMD) and social activities disorder (SAD), with more than 55.8% of total variances. The ICC for different factors of Persian version of Young Questionnaire including PAD, EMD and for SAD was r = 0.884; CI 95%; 0.861 - 0.904, r = 0.766; CI 95%; 0.718 - 0.808 and r = 0.745; CI 95%; 0.686 - 0.795, respectively. Conclusions: Our study showed that the Persian version of YIAT is good and usable on Iranian people. The reliability of the instrument was very good. Moreover, the validity of the Persian translated version of the scale was sufficient. In addition, the reliability and validity of the three extracted factors of YIAT were evaluated and were acceptable. PMID:26495253

  8. An Icelandic Version of McMasters Family Assessment Device (FAD)

    ERIC Educational Resources Information Center

    Juliusdottir, Gudlaug M.; Olafsdottir, Hrefna

    2015-01-01

    Purpose: An analysis of the psychometric properties of an Icelandic version of McMasters Family Assessment Device (FAD) was conducted in this study. Method: Two groups, clinical and nonclinical, comprising of 529 parents answered the FAD. The study examined the internal reliability and discriminant validity of the instrument in addition to…

  9. Reproducibility of Dual-Microphone Voice Range Profile Equipment

    ERIC Educational Resources Information Center

    Printz, Trine; Pedersen, Ellen Raben; Juhl, Peter; Nielsen, Troels; Grøntved, Ågot Møller; Godballe, Christian

    2017-01-01

    Purpose: The aim of this study was to add further knowledge about the usefulness of the Voice Range Profile (VRP) assessment in clinical settings and research by analyzing VRP dual-microphone equipment precision, reliability, and room effect. Method: Test-retest studies were conducted in an anechoic chamber and an office: (a) comparing sound…

  10. IMPACTS OF TECHNOLOGICAL CHANGES IN WAREHOUSING, PHASE I.

    ERIC Educational Resources Information Center

    HAMILTON, PHYLLIS D.; KINCAID, HARRY V.

    THE OBJECTIVES OF THIS STUDY WERE (1) TO DETERMINE THE AVAILABILITY, NATURE, AND RELIABILITY OF DATA ON THE RAPID CHANGE IN THE WAREHOUSING FUNCTION IN INDUSTRY AND (2) TO PROVIDE A BASIS FOR DECISIONS CONCERNING THE DESIRABILITY AND FEASIBILITY OF CONDUCTING SUBSEQUENT STUDIES. THREE MAJOR SOURCES OF INFORMATION ON CALIFORNIA, OREGON, WASHINGTON,…

  11. Cognitive Age: A New Multidimensional Approach to Measuring Age Identity.

    ERIC Educational Resources Information Center

    Barak, Benny

    1987-01-01

    Conducted exploratory field study to examine how age-concepts are experienced and to assess relationship of age identities to each other. Proposes Cognitive Age as a new multidimensional age scale that merges the standard scale, Identity Age, and Personal Age. Study results attest to Cognitive Age scale's reliability and validity. (Author/NB)

  12. Child and Adolescent Behaviorally Based Disorders: A Critical Review of Reliability and Validity

    ERIC Educational Resources Information Center

    Mallett, Christopher A.

    2014-01-01

    Objectives: The purpose of this study was to investigate the historical construction and empirical support of two child and adolescent behaviorally based mental health disorders: oppositional defiant and conduct disorders. Method: The study utilized a historiography methodology to review, from 1880 to 2012, these disorders' inclusion in…

  13. Critical Pedagogy: EFL Teachers' Views, Experience and Academic Degrees

    ERIC Educational Resources Information Center

    Mahmoodarabi, Mahsa; Khodabakhsh, Mohammad Reza

    2015-01-01

    Although critical pedagogy has brought about positive changes in the field of education by shifting from traditional pedagogy to emancipatory pedagogy, not much attention has been paid to the factors affecting teachers' beliefs of critical pedagogy and only few studies have been conducted to design reliable and valid instruments to study EFL…

  14. FDDS: A Cross Validation Study.

    ERIC Educational Resources Information Center

    Sawyer, Judy Parsons

    The Family Drawing Depression Scale (FDDS) was created by Wright and McIntyre to provide a clear and reliable scoring method for the Kinetic Family Drawing as a procedure for detecting depression. A study was conducted to confirm the value of the FDDS as a systematic tool for interpreting family drawings with populations of depressed individuals.…

  15. Scale Development: Heterosexist Attitudes in Women's Collegiate Athletics

    ERIC Educational Resources Information Center

    Mullin, Elizabeth M.

    2013-01-01

    Homophobia and heterosexism in women's athletics have been studied extensively using a qualitative approach. Limited research from a quantitative approach has been conducted in the area and none with a sport-specific instrument. The purpose of the current study was to develop a valid and reliable questionnaire to measure heterosexist attitudes in…

  16. Attitude of Students towards Teaching Profession in Nigeria: Implications for Education Development

    ERIC Educational Resources Information Center

    Egwu, Sarah Oben

    2015-01-01

    The study was conducted to ascertain attitude of students towards teaching profession in Faculty of Education, Ebonyi State University, Abakaliki. A sample of 300 students completed a 15 item questionnaire designed for the study the instrument was validated and the reliability calculated which was 0.92 using Pearson product moment correlation…

  17. Translation, Adaptation, and Preliminary Validation of the Female Sexual Function Index into Spanish (Colombia).

    PubMed

    Vallejo-Medina, Pablo; Pérez-Durán, Claudia; Saavedra-Roa, Alejandro

    2018-04-01

    The Female Sexual Function Index (FSFI) subjectively explores the dimensions of female sexual functioning. This research undertook to adapt and validate the FSFI to Spanish language in a Colombian sample. To this effect, this study was conducted in two steps, namely: (1) cultural adaptation of the scale with the collaboration of seven experts; and (2) preliminary validation of the scale in a sample of 925 participants. Reliability indices were appropriate in this sample, and external validity in relation to other measures showed significant relationships. Findings suggest that the FSFI is reliable and valid in Spanish for a Colombian population. Further research is needed to establish the test-retest reliability and discriminant validity of this Spanish version.

  18. Studies of advanced glycation end products and oxidation biomarkers for type 2 diabetes.

    PubMed

    Chiu, Chung-Jung; Rabbani, Naila; Rowan, Sheldon; Chang, Min-Lee; Sawyer, Sherilyn; Hu, Frank B; Willett, Walter; Thornalley, Paul J; Anwar, Attia; Bar, Liliana; Kang, Jae H; Taylor, Allen

    2018-05-02

    Advanced glycation end products (AGEs) are formed upon nonenzymatic reactions of sugars or their metabolites with proteins and other cellular constituents. Many AGEs are long lived. Recent findings suggest that AGEs may predict diabetes and its complications and thus may warrant further study. The objective of this study was to assess the validity of our experimental procedures for measuring AGEs in stored blood sample and to conduct a pilot study for developing AGE biomarkers for diabetes and/or age-related changes of glucose metabolism. We conducted a reliability study of the samples and methods using liquid chromatography-tandem mass spectrometry (LC-MS)/MS assays for 10 AGEs (including methylglyoxal-derived hydroimidazolone (MG-H1), glucosepane (GSP) and two oxidation measures, in stored repository blood samples from the Nurses' Health Study and the Health Professionals Follow-up Study. We also analyzed data relating blood GSP levels to type 2 diabetes status in a case-control study (25 cases and 15 controls). Among the AGEs, GSP, and MG-H1 showed the highest reliability across the various measures: reliability in duplicate samples and stability with delayed processing and storage over 1-2 year period. Furthermore, plasma GSP was associated with older age (P = 0.04) and type 2 diabetes status (age-adjusted P = 0.0475). Our findings suggest that analysis of these AGEs may be developed as biomarkers for diabetes and/or age-related changes of glucose metabolism. © 2018 BioFactors, 2018. © 2018 International Union of Biochemistry and Molecular Biology.

  19. Reliability and validity of the Turkish version of the Structured Clinical Interview for DSM-IV Dissociative Disorders (SCID-D): a preliminary study.

    PubMed

    Kundakçi, Turgut; Sar, Vedat; Kiziltan, Emre; Yargiç, Ilhan L; Tutkun, Hamdi

    2014-01-01

    A total of 34 consecutive patients with dissociative identity disorder or dissociative disorder not otherwise specified were evaluated using the Turkish version of the Structured Clinical Interview for DSM-IV Dissociative Disorders (SCID-D). They were compared with a matched control group composed of 34 patients who had a nondissociative psychiatric disorder. Interrater reliability was evaluated by 3 clinicians who assessed videotaped interviews conducted with 5 dissociative and 5 nondissociative patients. All subjects who were previously diagnosed by clinicians as having a dissociative disorder were identified as positive, and all subjects who were previously diagnosed as not having a dissociative disorder were identified as negative. The scores of the main symptom clusters and the total score of the SCID-D differentiated dissociative patients from the nondissociative group. There were strong correlations between the SCID-D and the Dissociative Experiences Scale total and subscale scores. These results are promising for the validity and reliability of the Turkish version of the SCID-D. However, as the present study was conducted on a predominantly female sample with very severe dissociation, these findings should not be generalized to male patients, to dissociative disorders other than dissociative identity disorder, or to broader clinical or nonclinical populations.

  20. Psychometric Characteristics of Process Evaluation Measures for a Rural School-based Childhood Obesity Prevention Study: Louisiana Health

    PubMed Central

    Newton, R. L.; Thomson, J. L.; Rau, K.; Duhe’, S.; Sample, A.; Singleton, N.; Anton, S. D.; Webber, L. S.; Williamson, D. A.

    2011-01-01

    Purpose To evaluate the implementation of intervention components of the Louisiana Health study, which was a multi-component childhood obesity prevention program conducted in rural schools. Design Content analysis. Setting Process evaluation assessed implementation in the classrooms, gym classes, and cafeterias. Subjects Classroom teachers (n = 232), physical education teachers (n = 53), food service managers (n = 33), and trained observers (n = 9). Measures Five process evaluation measures were created: Physical Education Questionnaire (PEQ), Intervention Questionnaire (IQ), Food Service Manager Questionnaire (FSMQ), Classroom Observation (CO) and School Nutrition Environment Observation (SNEO). Analysis Inter-rater reliability and internal consistency were conducted on all measures. ANOVA and Chi-square were used to compare differences across study groups on questionnaires and observations. Results The PEQ and one sub-scale from the FSMQ were eliminated because their reliability coefficients fell below acceptable standards. The sub-scale internal consistencies for the IQ, FSMQ, CO, and SNEO (all Cronbach’s α > .60) were acceptable. Conclusions After the initial 4 months of intervention, there was evidence that the Louisiana Health intervention was being implemented as it was designed. In summary, four process evaluation measures were found to be sufficiently reliable and valid for assessing the delivery of various aspects of a school-based obesity prevention program. These process measures could be modified to evaluate the delivery of other similar school-based interventions. PMID:21721969

  1. An assessment of the intra- and inter-reliability of the lumbar paraspinal muscle parameters using CT scan and magnetic resonance imaging.

    PubMed

    Hu, Zhi-Jun; He, Jian; Zhao, Feng-Dong; Fang, Xiang-Qian; Zhou, Li-Na; Fan, Shun-Wu

    2011-06-01

    A reliability study was conducted. To estimate the intra- and intermeasurement errors in the measurements of functional cross-sectional area (FCSA), density, and T2 signal intensity of paraspinal muscles using computed tomography (CT) scan and magnetic resonance imaging (MRI). CT scan and MRI had been used widely to measure the cross-sectional area and degeneration of the back muscles in spine and muscle research. But there is still no systemic study to analyze the reliability of these measurements. This study measured the FCSA and fatty infiltration (density on CT scan and T2 signal intensity on MRI) of the paraspinal muscles at L3-L4, L4-L5, and L5-S1 in 29 patients with chronic low back pain. Two experienced musculoskeletal radiologists and one superior spine surgeon traced the region of interest twice within 3 weeks for measurement of the intra- and interobserver reliability. The intraclass correlation coefficients (ICCs) of the intra-reliability ranged from fair to excellent for FCSA, and good to excellent for fatty infiltration. The ICCs of the inter-reliability ranged from fair to excellent for FCSA, and good to excellent for fatty infiltration. There were no significant differences between CT scan and MRI in reliability results, except in the relative standard error of fatty infiltration measurement. The ICCs of the FCSA measurement between CT scan and MRI ranged from poor to good. The reliabilities of the CT scan and MRI for measuring the FCSA and fatty infiltration of the atrophied lumbar paraspinal muscles were acceptable. It was reliable for using uniform one image method for a single paraspinal muscle evaluation study. And the authors preferred to advise the MRI other than CT scan for paraspinal muscles measurements of FCSA and fatty infiltration.

  2. Evaluation of a respiratory symptom diary for clinical studies of idiopathic pulmonary fibrosis.

    PubMed

    Bacci, Elizabeth Dansie; O'Quinn, Sean; Leidy, Nancy Kline; Murray, Lindsey; Vernon, Margaret

    2018-01-01

    There are no validated patient diaries for evaluating respiratory symptoms in idiopathic pulmonary fibrosis (IPF). To evaluate the performance properties of the chronic obstructive pulmonary disease (COPD) Evaluating Respiratory Symptoms™ (E-RS™: COPD) measure in patients with IPF. Concept elicitation and cognitive interviews were conducted with IPF patients to evaluate content validity, including comprehensiveness, relevance, and interpretability of E-RS™ items in this patient population. Secondary analyses of IPF clinical study data were performed to evaluate the scoring structure of the tool. With modifications, reliability, validity, and responsiveness of the instrument (E-RS™: IPF) were evaluated. Qualitative interviews (n = 30) were conducted. During the elicitation interviews (n = 20), concept saturation for IPF respiratory symptoms was achieved; all respiratory symptoms covered by the E-RS™ were endorsed by ≥ 30% of the sample. During cognitive interviews (n = 10), all participants found the items interpretable and relevant. Factor analyses conducted via secondary analysis of IPF clinical study data identified no total score and four symptom scales: Chest, Breathlessness, Cough, and Sputum. Reliability of each scale was high (internal consistency [α] >0.85); 2-day reproducibility (ICC >0.88). Validity was supported through significant (P < 0.0001) relationships with the St. George's Respiratory Questionnaire (SGRQ), the University of California, San Diego Shortness of Breath Questionnaire (UCSD-SOBQ), and other variables. The scales were responsive to change when evaluated using SGRQ Symptoms, UCSD-SOBQ, and Patient Global Impression of Change as anchors (P < 0.01 to P < 0.0001). The E-RS™: IPF is a valid, reliable, and responsive tool for evaluating respiratory symptoms in patients with IPF. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  3. Reliability of self-reported smoking history and age at initial tobacco use.

    PubMed

    Huerta, Michael; Chodick, Gabriel; Balicer, Ran D; Davidovitch, Nadav; Grotto, Itamar

    2005-08-01

    Many studies use questionnaires to determine smoking status and age of smoking onset. This study aimed to determine the reliability of self-reported smoking history and age of smoking initiation. The proportion of inconsistent answers and correlation coefficients of reported age of initial smoking were measured by an answer-reanswer analysis of questionnaires in an ongoing, two-step, population-based survey of health behavior. Interviews were conducted on the day of recruitment to and the day of discharge from mandatory military service in Israel among a sample of 25,437 young men and women recruited between 1986 and 2000. Of 7276 participants reporting current or past smoking upon recruitment, 559 (7.7%) reported never having smoked upon discharge, thus demonstrating prima facie inconsistency. Variables significantly associated with reliable reporting in a multivariate logistic regression model were female gender (P = 0.04) and more than 4 years of military service (P < 0.01). 6010 subjects who reported a positive smoking history at both recruitment and discharge were available for analysis of reliability of reported age at smoking onset. Intraclass correlation coefficients for recruitment/discharge consistency in reported age at first cigarette were 0.73 (95% CI: 0.71-0.74) and 0.76 (95% CI: 0.74-0.78) for men and women, respectively. Eastern origin, lower subject education level, and lower paternal education level were also associated with lower reliability. Our results showed a relatively high level of answer-reanswer reliability, with some variance attributable to personal characteristics. These results suggest that self-reported age at onset of tobacco use is practical and reliable in normative, young adult populations. However, time elapsed between questionnaires and demographic and lifestyle characteristics may affect reliability rates, and thus should be carefully regarded in future studies.

  4. Assessing Reliability of Medical Record Reviews for the Detection of Hospital Adverse Events.

    PubMed

    Ock, Minsu; Lee, Sang-il; Jo, Min-Woo; Lee, Jin Yong; Kim, Seon-Ha

    2015-09-01

    The purpose of this study was to assess the inter-rater reliability and intra-rater reliability of medical record review for the detection of hospital adverse events. We conducted two stages retrospective medical records review of a random sample of 96 patients from one acute-care general hospital. The first stage was an explicit patient record review by two nurses to detect the presence of 41 screening criteria (SC). The second stage was an implicit structured review by two physicians to identify the occurrence of adverse events from the positive cases on the SC. The inter-rater reliability of two nurses and that of two physicians were assessed. The intra-rater reliability was also evaluated by using test-retest method at approximately two weeks later. In 84.2% of the patient medical records, the nurses agreed as to the necessity for the second stage review (kappa, 0.68; 95% confidence interval [CI], 0.54 to 0.83). In 93.0% of the patient medical records screened by nurses, the physicians agreed about the absence or presence of adverse events (kappa, 0.71; 95% CI, 0.44 to 0.97). When assessing intra-rater reliability, the kappa indices of two nurses were 0.54 (95% CI, 0.31 to 0.77) and 0.67 (95% CI, 0.47 to 0.87), whereas those of two physicians were 0.87 (95% CI, 0.62 to 1.00) and 0.37 (95% CI, -0.16 to 0.89). In this study, the medical record review for detecting adverse events showed intermediate to good level of inter-rater and intra-rater reliability. Well organized training program for reviewers and clearly defining SC are required to get more reliable results in the hospital adverse event study.

  5. Rendezvous strategy impacts on CTV avionics design, system reliability requirements, and available collision avoidance maneuvers

    NASA Technical Reports Server (NTRS)

    Donovan, William J.; Davis, John E.

    1991-01-01

    Rockwell International is conducting an ongoing program to develop avionics architectures that provide high intrinsic value while meeting all mission objectives. Studies are being conducted to determine alternative configurations that have low life-cycle cost and minimum development risk, and that minimize launch delays while providing the reliability level to assure a successful mission. This effort is based on four decades of providing ballistic missile avionics to the United States Air Force and has focused on the requirements of the NASA Cargo Transfer Vehicle (CTV) program in 1991. During the development of architectural concepts it became apparent that rendezvous strategy issues have an impact on the architecture of the avionics system. This is in addition to the expected impact on propulsion and electrical power duration, flight profiles, and trajectory during approach.

  6. Reliability of Instruments Measuring At-Risk and Problem Gambling Among Young Individuals: A Systematic Review Covering Years 2009-2015.

    PubMed

    Edgren, Robert; Castrén, Sari; Mäkelä, Marjukka; Pörtfors, Pia; Alho, Hannu; Salonen, Anne H

    2016-06-01

    This review aims to clarify which instruments measuring at-risk and problem gambling (ARPG) among youth are reliable and valid in light of reported estimates of internal consistency, classification accuracy, and psychometric properties. A systematic search was conducted in PubMed, Medline, and PsycInfo covering the years 2009-2015. In total, 50 original research articles fulfilled the inclusion criteria: target age under 29 years, using an instrument designed for youth, and reporting a reliability estimate. Articles were evaluated with the revised Quality Assessment of Diagnostic Accuracy Studies tool. Reliability estimates were reported for five ARPG instruments. Most studies (66%) evaluated the South Oaks Gambling Screen Revised for Adolescents. The Gambling Addictive Behavior Scale for Adolescents was the only novel instrument. In general, the evaluation of instrument reliability was superficial. Despite its rare use, the Canadian Adolescent Gambling Inventory (CAGI) had a strong theoretical and methodological base. The Gambling Addictive Behavior Scale for Adolescents and the CAGI were the only instruments originally developed for youth. All studies, except the CAGI study, were population based. ARPG instruments for youth have not been rigorously evaluated yet. Further research is needed especially concerning instruments designed for clinical use. Copyright © 2016 The Society for Adolescent Health and Medicine. Published by Elsevier Inc. All rights reserved.

  7. The Reliability and Validity of the Computerized Double Inclinometer in Measuring Lumbar Mobility

    PubMed Central

    MacDermid, Joy Christine; Arumugam, Vanitha; Vincent, Joshua Israel; Carroll, Krista L

    2014-01-01

    Study Design : Repeated measures reliability/validity study. Objectives : To determine the concurrent validity, test-retest, inter-rater and intra-rater reliability of lumbar flexion and extension measurements using the Tracker M.E. computerized dual inclinometer (CDI) in comparison to the modified-modified Schober (MMS) Summary of Background : Numerous studies have evaluated the reliability and validity of the various methods of measuring spinal motion, but the results are inconsistent. Differences in equipment and techniques make it difficult to correlate results. Methods : Twenty subjects with back pain and twenty without back pain were selected through convenience sampling. Two examiners measured sagittal plane lumbar range of motion for each subject. Two separate tests with the CDI and one test with the MMS were conducted. Each test consisted of three trials. Instrument and examiner order was randomly assigned. Intra-class correlations (ICCs 2, 2 and 2, 2) and Pearson correlation coefficients (r) were used to calculate reliability and concurrent validity respectively. Results : Intra-trial reliability was high to very high for both the CDI (ICCs 0.85 - 0.96) and MMS (ICCs 0.84 - 0.98). However, the reliability was poor to moderate, when the CDI unit had to be repositioned either by the same rate (ICCs 0.16 - 0.59) or a different rater (ICCs 0.45 - 0.52). Inter-rater reliability for the MMS was moderate to high (ICCs 0.75 - 0.82) which bettered the moderate correlation obtained for the CDI (ICCs 0.45 - 0.52). Correlations between the CDI and MMS were poor for flexion (0.32; p<0.05) and poor to moderate (-0.42 - -0.51; p<0.05) for extension measurements. Conclusion : When using the CDI, an average of subsequent tests is required to obtain moderate reliability. The MMS was highly reliable than the CDI. The MMS and the CDI measure lumbar movement on a different metric that are not highly related to each other. PMID:25352928

  8. Reliability of physical examination tests for the diagnosis of knee disorders: Evidence from a systematic review.

    PubMed

    Décary, Simon; Ouellet, Philippe; Vendittoli, Pascal-André; Desmeules, François

    2016-12-01

    Clinicians often rely on physical examination tests to guide them in the diagnostic process of knee disorders. However, reliability of these tests is often overlooked and may influence the consistency of results and overall diagnostic validity. Therefore, the objective of this study was to systematically review evidence on the reliability of physical examination tests for the diagnosis of knee disorders. A structured literature search was conducted in databases up to January 2016. Included studies needed to report reliability measures of at least one physical test for any knee disorder. Methodological quality was evaluated using the QAREL checklist. A qualitative synthesis of the evidence was performed. Thirty-three studies were included with a mean QAREL score of 5.5 ± 0.5. Based on low to moderate quality evidence, the Thessaly test for meniscal injuries reached moderate inter-rater reliability (k = 0.54). Based on moderate to excellent quality evidence, the Lachman for anterior cruciate ligament injuries reached moderate to excellent inter-rater reliability (k = 0.42 to 0.81). Based on low to moderate quality evidence, the Tibiofemoral Crepitus, Joint Line and Patellofemoral Pain/Tenderness, Bony Enlargement and Joint Pain on Movement tests for knee osteoarthritis reached fair to excellent inter-rater reliability (k = 0.29 to 0.93). Based on low to moderate quality evidence, the Lateral Glide, Lateral Tilt, Lateral Pull and Quality of Movement tests for patellofemoral pain reached moderate to good inter-rater reliability (k = 0.49 to 0.73). Many physical tests appear to reach good inter-rater reliability, but this is based on low-quality and conflicting evidence. High-quality research is required to evaluate the reliability of knee physical examination tests. Copyright © 2016 Elsevier Ltd. All rights reserved.

  9. Reliability of capturing foot parameters using digital scanning and the neutral suspension casting technique

    PubMed Central

    2011-01-01

    Background A clinical study was conducted to determine the intra and inter-rater reliability of digital scanning and the neutral suspension casting technique to measure six foot parameters. The neutral suspension casting technique is a commonly utilised method for obtaining a negative impression of the foot prior to orthotic fabrication. Digital scanning offers an alternative to the traditional plaster of Paris techniques. Methods Twenty one healthy participants volunteered to take part in the study. Six casts and six digital scans were obtained from each participant by two raters of differing clinical experience. The foot parameters chosen for investigation were cast length (mm), forefoot width (mm), rearfoot width (mm), medial arch height (mm), lateral arch height (mm) and forefoot to rearfoot alignment (degrees). Intraclass correlation coefficients (ICC) with 95% confidence intervals (CI) were calculated to determine the intra and inter-rater reliability. Measurement error was assessed through the calculation of the standard error of the measurement (SEM) and smallest real difference (SRD). Results ICC values for all foot parameters using digital scanning ranged between 0.81-0.99 for both intra and inter-rater reliability. For neutral suspension casting technique inter-rater reliability values ranged from 0.57-0.99 and intra-rater reliability values ranging from 0.36-0.99 for rater 1 and 0.49-0.99 for rater 2. Conclusions The findings of this study indicate that digital scanning is a reliable technique, irrespective of clinical experience, with reduced measurement variability in all foot parameters investigated when compared to neutral suspension casting. PMID:21375757

  10. Reliability of an fMRI Paradigm for Emotional Processing in a Multisite Longitudinal Study

    PubMed Central

    Gee, Dylan G.; McEwen, Sarah C.; Forsyth, Jennifer K.; Haut, Kristen M.; Bearden, Carrie E.; Addington, Jean; Goodyear, Bradley; Cadenhead, Kristin S.; Mirzakhanian, Heline; Cornblatt, Barbara A.; Olvet, Doreen; Mathalon, Daniel H.; McGlashan, Thomas H.; Perkins, Diana O.; Belger, Aysenil; Seidman, Larry J.; Thermenos, Heidi; Tsuang, Ming T.; van Erp, Theo G.M.; Walker, Elaine F.; Hamann, Stephan; Woods, Scott W.; Constable, Todd; Cannon, Tyrone D.

    2015-01-01

    Multisite neuroimaging studies can facilitate the investigation of brain-related changes in many contexts, including patient groups that are relatively rare in the general population. Though multisite studies have characterized the reliability of brain activation during working memory and motor functional magnetic resonance imaging tasks, emotion processing tasks, pertinent to many clinical populations, remain less explored. A traveling participants study was conducted with eight healthy volunteers scanned twice on consecutive days at each of the eight North American Longitudinal Prodrome Study sites. Tests derived from generalizability theory showed excellent reliability in the amygdala (Eρ2=0.82), inferior frontal gyrus (IFG;Eρ2=0.83), anterior cingulate cortex (ACC;Eρ2=0.76), insula (Eρ2=0.85), and fusiform gyrus (Eρ2=0.91) for maximum activation and fair to excellent reliability in the amygdala (Eρ2=0.44), IFG (Eρ2=0.48), ACC (Eρ2=0.55), insula (Eρ2=0.42), and fusiform gyrus (Eρ2=0.83) for mean activation across sites and test days. For the amygdala, habituation (Eρ2=0.71) was more stable than mean activation. In a second investigation, data from 111 healthy individuals across sites were aggregated in a voxelwise, quantitative meta-analysis. When compared with a mixed effects model controlling for site, both approaches identified robust activation in regions consistent with expected results based on prior single-site research. Overall, regions central to emotion processing showed strong reliability in the traveling participants study and robust activation in the aggregation study. These results support the reliability of blood oxygen level-dependent signal in emotion processing areas across different sites and scanners and may inform future efforts to increase efficiency and enhance knowledge of rare conditions in the population through multisite neuroimaging paradigms. PMID:25821147

  11. The development and validation of the Clinical Teaching Behavior Inventory (CTBI-23): Nurse preceptors' and new graduate nurses' perceptions of precepting.

    PubMed

    Lee-Hsieh, Jane; O'Brien, Anthony; Liu, Chieh-Yu; Cheng, Su-Fen; Lee, Yea-Wen; Kao, Yu-Hsiu

    2016-03-01

    Few studies have examined the perceptions of clinical teaching behaviors among both nurse preceptors and preceptees. To develop a Clinical Teaching Behavior Inventory (CTBI) for nurse preceptors' self-evaluation, and for new graduate nurse preceptee evaluation of preceptor clinical teaching behaviors and to test the validity and reliability of the CTBI. This study used mixed research techniques in five phases. Phase I: based on a literature review, the researchers developed an instrument to measure clinical teaching behaviors. Phase II: 17 focus group interviews were conducted with 63 preceptors and 24 new graduate nurses from five hospitals across Taiwan. Clinical teaching behavior themes were extracted from the focus group data and integrated into the domains and items of the CTBI. Phase III: two rounds of an expert Delphi study were conducted to determine the content validity of the instrument. Phase IV: a total of 290 nurse preceptors and 260 new graduate nurses were recruited voluntarily in the same five hospitals in Taiwan. Of these, 521 completed questionnaires to test the construct validity of CTBI by using confirmatory factory analysis. Phase V: the internal consistency and reliability of the instrument were tested. CTBI consists of 23 items in six domains: (1) 'Committing to Teaching'; (2) 'Building a Learning Atmosphere'; (3) 'Using Appropriate Teaching Strategies'; (4) 'Guiding Inter-professional Communication'; (5) 'Providing Feedback and Evaluation'; and (6) 'Showing Concern and Support'. The confirmatory factor analysis yielded a good fit and reliable scores for the CTBI-23 model. The CTBI-23 is a valid and reliable instrument for identifying the clinical teaching behaviors of a preceptor as perceived by preceptors and new graduate preceptees. The CTBI-23 depicts clinical teaching behaviors of nurse preceptors in Taiwan. Copyright © 2015 Elsevier Ltd. All rights reserved.

  12. Work design and management in the manufacturing sector: development and validation of the Work Organisation Assessment Questionnaire.

    PubMed

    Griffiths, A; Cox, T; Karanika, M; Khan, S; Tomás, J M

    2006-10-01

    To examine the factor structure, reliability, and validity of a new context-specific questionnaire for the assessment of work and organisational factors. The Work Organisation Assessment Questionnaire (WOAQ) was developed as part of a risk assessment and risk reduction methodology for hazards inherent in the design and management of work in the manufacturing sector. Two studies were conducted. Data were collected from 524 white- and blue-collar employees from a range of manufacturing companies. Exploratory factor analysis was carried out on 28 items that described the most commonly reported failures of work design and management in companies in the manufacturing sector. Concurrent validity data were also collected. A reliability study was conducted with a further 156 employees. Principal component analysis, with varimax rotation, revealed a strong 28-item, five factor structure. The factors were named: quality of relationships with management, reward and recognition, workload, quality of relationships with colleagues, and quality of physical environment. Analyses also revealed a more general summative factor. Results indicated that the questionnaire has good internal consistency and test-retest reliability and validity. Being associated with poor employee health and changes in health related behaviour, the WOAQ factors are possible hazards. It is argued that the strength of those associations offers some estimation of risk. Feedback from the organisations involved indicated that the WOAQ was easy to use and meaningful for them as part of their risk assessment procedures. The studies reported here describe a model of the hazards to employee health and health related behaviour inherent in the design and management of work in the manufacturing sector. It offers an instrument for their assessment. The scales derived which form the WOAQ were shown to be reliable, valid, and meaningful to the user population.

  13. The End-Stage Renal Disease Adherence Questionnaire (ESRD-AQ): testing the psychometric properties in patients receiving in-center hemodialysis.

    PubMed

    Kim, Youngmee; Evangelista, Lorraine S; Phillips, Linda R; Pavlish, Carol; Kopple, Joel D

    2010-01-01

    Reported treatment adherence rates of patients with end stage renal disease (ESRD) have been extremely varied due to lack of reliable and valid measurement tools. This study was conducted to develop and test an instrument to measure treatment adherence to hemodialysis (HD) attendance, medications, fluid restrictions, and diet prescription among patients with ESRD. This article describes the methodological approach used to develop and test the psychometric properties (such as reliability and validity) of the 46-item ESRD-Adherence Questionnaire (ESRD-AQ) in a cohort of patients receiving maintenance HD at dialysis centers in Los Angeles County. The ESRD-AQ is the first self-report instrument to address all components of adherence behaviors of patients with ESRD. The findings support that the instrument is reliable and valid and is easy to administer. Future studies are needed in a larger sample to determine whether additional modifications are needed.

  14. Study on the stability and reliability of Clinotron at Y-band

    NASA Astrophysics Data System (ADS)

    Li, Shuang; Wang, Jianguo; Chen, Zaigao; Wang, Guangqiang; Wang, Dongyang; Teng, Yan

    2017-11-01

    To improve the stability and reliability of Clinotron at the Y-band, some key issues are researched, such as the synchronous operating mode, the heat accumulation on the slow-wave structure, and the errors in micro-fabrication. By analyzing the dispersion relationship, the working mode is determined as the TM10 mode. The problem of heat dissipation on a comb is researched to make a trade-off on the choice of suitable working conditions, making sure that the safety and efficiency of the device are guaranteed simultaneously. The study on the effect of tolerance on device's performance is also conducted to determine the acceptable error during micro-fabrication. The validity of the device and the cost for fabrication are both taken into consideration. At last, the performance of Clinotron under the optimized conditions demonstrates that it can work steadily at 315.89 GHz and the output power is about 12 W, showing advanced stability and reliability.

  15. Characterising the reproducibility and reliability of dietary patterns among Yup'ik Alaska Native people.

    PubMed

    Ryman, Tove K; Boyer, Bert B; Hopkins, Scarlett; Philip, Jacques; O'Brien, Diane; Thummel, Kenneth; Austin, Melissa A

    2015-02-28

    FFQ data can be used to characterise dietary patterns for diet-disease association studies. In the present study, we evaluated three previously defined dietary patterns--'subsistence foods', market-based 'processed foods' and 'fruits and vegetables'--among a sample of Yup'ik people from Southwest Alaska. We tested the reproducibility and reliability of the dietary patterns, as well as the associations of these patterns with dietary biomarkers and participant characteristics. We analysed data from adult study participants who completed at least one FFQ with the Center for Alaska Native Health Research 9/2009-5/2013. To test the reproducibility of the dietary patterns, we conducted a confirmatory factor analysis (CFA) of a hypothesised model using eighteen food items to measure the dietary patterns (n 272). To test the reliability of the dietary patterns, we used the CFA to measure composite reliability (n 272) and intra-class correlation coefficients for test-retest reliability (n 113). Finally, to test the associations, we used linear regression (n 637). All factor loadings, except one, in CFA indicated acceptable correlations between foods and dietary patterns (r>0·40), and model-fit criteria were >0·90. Composite and test-retest reliability of the dietary patterns were, respectively, 0·56 and 0·34 for 'subsistence foods', 0·73 and 0·66 for 'processed foods', and 0·72 and 0·54 for 'fruits and vegetables'. In the multi-predictor analysis, the dietary patterns were significantly associated with dietary biomarkers, community location, age, sex and self-reported lifestyle. This analysis confirmed the reproducibility and reliability of the dietary patterns in the present study population. These dietary patterns can be used for future research and development of dietary interventions in this underserved population.

  16. CHAT: development and validation of a computer-delivered, self-report, substance use assessment for adolescents.

    PubMed

    Lord, Sarah E; Trudeau, Kimberlee J; Black, Ryan A; Lorin, Lucy; Cooney, Elizabeth; Villapiano, Albert; Butler, Stephen F

    2011-01-01

    The current study was conducted to construct and validate a computer-delivered, multimedia, substance use self-assessment for adolescents. Reliability and validity of six problem dimensions were evaluated in two studies, conducted from 2003 to 2008. Study 1 included 192 adolescents from five treatment settings throughout the United States (N = 142) and two high schools from Greater Boston, Massachusetts (N = 50). Study 2 included 356 adolescents (treatment: N = 260; school: N = 94). The final version of Comprehensive Health Assessment for Teens (CHAT) demonstrated relatively strong psychometric properties. The limitations and implications of this study are noted. This study was supported by an SBIR grant.

  17. The Development and Psychometric Properties of the Immigration Law Concerns Scale (ILCS) for HIV Testing.

    PubMed

    Lechuga, Julia; Galletly, Carol L; Broaddus, Michelle R; Dickson-Gomez, Julia B; Glasman, Laura R; McAuliffe, Timothy L; Vega, Miriam Y; LeGrand, Sarah; Mena, Carla A; Barlow, Morgan L; Valera, Erik; Montenegro, Judith I

    2017-11-08

    To develop, pilot test, and conduct psychometric analyses of an innovative scale measuring the influence of perceived immigration laws on Latino migrants' HIV-testing behavior. The Immigration Law Concerns Scale (ILCS) was developed in three phases: Phase 1 involved a review of law and literature, generation of scale items, consultation with project advisors, and subsequent revision of the scale. Phase 2 involved systematic translation- back translation and consensus-based editorial processes conducted by members of a bilingual and multi-national study team. In Phase 3, 339 sexually active, HIV-negative Spanish-speaking, non-citizen Latino migrant adults (both documented and undocumented) completed the scale via audio computer-assisted self-interview. The psychometric properties of the scale were tested with exploratory factor analysis and estimates of reliability coefficients were generated. Bivariate correlations were conducted to test the discriminant and predictive validity of identified factors. Exploratory factor analysis revealed a three-factor, 17-item scale. subscale reliability ranged from 0.72 to 0.79. There were significant associations between the ILCS and the HIV-testing behaviors of participants. Results of the pilot test and psychometric analysis of the ILCS are promising. The scale is reliable and significantly associated with the HIV-testing behaviors of participants. Subscales related to unwanted government attention and concerns about meeting moral character requirements should be refined.

  18. [Psychometric properties of the Polish version of the Oldenburg Burnout Inventory (OLBI)].

    PubMed

    Baka, Łukasz; Basińska, Beata A

    2016-01-01

    The objective of this study was to test the psychometric properties of the Polish version of the Oldenburg Burnout Inventory (OLBI) - its factor structure, reliability, validity and standard norms. The study was conducted on 3 independent samples of 1804, 366 and 48 workers employed in social service and general service professions. To test the OLBI structure the exploratory factor analysis was conducted. The reliability was assessed by means of Cronbach's α coefficient (the internal consistent) and test-retest (the stability over time) method, with a 6-week follow-up. The construct validity of the OLBI was tested by means of correlation analysis, using perceived stress and work engagement as the criterion variables. The result of the factor analysis confirmed a 2-factor structure of the Inventory but the construction of each factor differed from that in the OLBI original version. Therefore, 2 separate factor analyses - each for the single component of job burnout (exhaustion and disengagement from work) - were conducted. The analyses revealed that each of the components consisted of 2 subscales. The reliability of the OLBI was supported by 2 methods. It was also proved that job burnout and its 2 components, exhaustion and disengagement from work, were positively correlated with perceived stress and negatively correlated with work engagement and its 3 components - vigor, absorption and dedication. Despite certain limitations the Polish version of the OLBI shows satisfactory psychometric properties and it can be used to measure job burnout in Polish conditions. This work is available in Open Access model and licensed under a CC BY-NC 3.0 PL license.

  19. The Validation of a Software Evaluation Instrument.

    ERIC Educational Resources Information Center

    Schmitt, Dorren Rafael

    This study, conducted at six southern universities, analyzed the validity and reliability of a researcher developed instrument designed to evaluate educational software in secondary mathematics. The instrument called the Instrument for Software Evaluation for Educators uses measurement scales, presents a summary section of the evaluation, and…

  20. Improving FHWA's Ability to Assess Highway Infrastructure Health : National Meeting Report

    DOT National Transportation Integrated Search

    2011-12-08

    The FHWA in coordination with AASHTO conducted a study to define a consistent and reliable method to document infrastructure health with a focus on pavements and bridges on the Interstate System, and to develop a framework for tools that can provide ...

  1. Historical Development of Asphalt Content Determination by the Ignition Method

    DOT National Transportation Integrated Search

    1996-01-01

    This study was conducted to develop a reliable, detailed test procedure for determining asphalt cement (AC) content by the ignition method. The goal was to minimize the overall test time as well as technician time, and to produce a test method with a...

  2. Psychometrics of the Iowa and Berlin Gambling Tasks: Unresolved Issues With Reliability and Validity for Risk Taking.

    PubMed

    Schmitz, Florian; Kunina-Habenicht, Olga; Hildebrandt, Andrea; Oberauer, Klaus; Wilhelm, Oliver

    2018-01-01

    The Iowa Gambling Task (IGT) is one of the most prominent paradigms employed for the assessment of risk taking in the laboratory, and it was shown to distinguish between various patient groups and controls. The present study was conducted to test the psychometric characteristics of the original IGT and of a new gambling task variant for assessing individual differences. Two studies were conducted with adults of the general population ( n = 220) and with adolescents ( n = 389). Participants were also tested on multiple measures of working memory capacity, fluid intelligence, personality traits associated with risk-taking behavior, and self-reported risk taking in various domains. Both gambling tasks had only moderate retest reliability within the same session. Moderate relations were obtained with cognitive ability. However, card selections in the gambling tasks were not correlated with personality or risk taking. These findings point to limitations of IGT type gambling tasks for the assessment of individual differences in risky decision making.

  3. Score Reliability and Construct Validity of the Flinn Performance Screening Tool for Adults With Symptoms of Carpal Tunnel Syndrome

    PubMed Central

    Flinn, Sharon R.; Pease, William S.; Freimer, Miriam L.

    2013-01-01

    OBJECTIVE We investigated the psychometric properties of the Flinn Performance Screening Tool (FPST) for people referred with symptoms of carpal tunnel syndrome (CTS). METHOD An occupational therapist collected data from 46 participants who completed the Functional Status Scale (FSS) and FPST after the participants’ nerve conduction velocity study to test convergent and contrasted-group validity. RESULTS Seventy-four percent of the participants had abnormal nerve conduction studies. Cronbach’s α coefficients for subscale and total scores of the FPST ranged from .96 to .98. Intrarater reliability for six shared items of the FSS and the FPST was supported by high agreement (71%) and a fair κ statistic (.36). Strong to moderate positive relationships were found between the FSS and FPST scores. Functional status differed significantly among severe, mild, and negative CTS severity groups. CONCLUSION The FPST shows adequate psychometric properties as a client-centered screening tool for occupational performance of people referred for symptoms of CTS. PMID:22549598

  4. QLiS--development of a schizophrenia-specific quality-of-life scale.

    PubMed

    Franz, Michael; Fritz, Michael; Gallhofer, Bernd; Meyer, Thorsten

    2012-06-07

    The aim of the project was to develop an instrument for the assessment of subjective quality of life specific to schizophrenic persons on the basis of patients' views on their own life and on sound psychometric principles. The project applied a six-step multiphase development process with six distinct studies. (1) The elicitation of schizophrenic persons' views on their quality of life was based on open-ended interviews with interviewees from different settings (acute ward inpatients, long-term care patients, community care patients; n = 268). (2) A cross-sectional study with schizophrenic and healthy persons was conducted to quantify the relative importance of the various aspect of quality of life that emerged from the qualitative study (n = 143). (3) We conducted an empirical comparison of response formats with schizophrenic persons (n = 32). (4) A scale construction- and reliability-testing study was performed (n = 203) as well as (5) a test-retest reliability study (n = 49). (6) The final questionnaire (QLiS, quality of life in schizophrenia) was tested in an additional study on convergent and discriminant validity (n = 135). The QLiS comprises 52 items (plus 2 optional items related to work) in 12 subscales: social contacts, appreciation by others, relationship to family, appraisal of pharmacotherapy, appraisal of psychopathological symptoms, cognitive functioning, abilities to manage daily living, appraisal of accommodation/housing, financial situation, leading a 'normal' life, confidence, general life-satisfaction. An item response format with four response categories was preferred by the schizophrenic persons. The mean values of the subscales clustered around the theoretical mean of the subscales and only minimal ceiling effects were found. The reliability (test-retest-reliability and internal consistency) was with one exception > .70 for all subscales. Taking the low numbers of items per subscale into account, the QLiS can be regarded as an accurate assessment instrument of subjective quality of life in schizophrenia with good content validity.

  5. Magnetoacoustic tomography with magnetic induction for high-resolution bioimepedance imaging through vector source reconstruction under the static field of MRI magnet

    PubMed Central

    Mariappan, Leo; Hu, Gang; He, Bin

    2014-01-01

    Purpose: Magnetoacoustic tomography with magnetic induction (MAT-MI) is an imaging modality to reconstruct the electrical conductivity of biological tissue based on the acoustic measurements of Lorentz force induced tissue vibration. This study presents the feasibility of the authors' new MAT-MI system and vector source imaging algorithm to perform a complete reconstruction of the conductivity distribution of real biological tissues with ultrasound spatial resolution. Methods: In the present study, using ultrasound beamformation, imaging point spread functions are designed to reconstruct the induced vector source in the object which is used to estimate the object conductivity distribution. Both numerical studies and phantom experiments are performed to demonstrate the merits of the proposed method. Also, through the numerical simulations, the full width half maximum of the imaging point spread function is calculated to estimate of the spatial resolution. The tissue phantom experiments are performed with a MAT-MI imaging system in the static field of a 9.4 T magnetic resonance imaging magnet. Results: The image reconstruction through vector beamformation in the numerical and experimental studies gives a reliable estimate of the conductivity distribution in the object with a ∼1.5 mm spatial resolution corresponding to the imaging system frequency of 500 kHz ultrasound. In addition, the experiment results suggest that MAT-MI under high static magnetic field environment is able to reconstruct images of tissue-mimicking gel phantoms and real tissue samples with reliable conductivity contrast. Conclusions: The results demonstrate that MAT-MI is able to image the electrical conductivity properties of biological tissues with better than 2 mm spatial resolution at 500 kHz, and the imaging with MAT-MI under a high static magnetic field environment is able to provide improved imaging contrast for biological tissue conductivity reconstruction. PMID:24506649

  6. Sexual behavioral abstine HIV/AIDS questionnaire: Validation study of an Iranian questionnaire

    PubMed Central

    Najarkolaei, Fatemeh Rahmati; Niknami, Shamsaddin; Shokravi, Farkhondeh Amin; Tavafian, Sedigheh Sadat; Fesharaki, Mohammad Gholami; Jafari, Mohammad Reza

    2014-01-01

    Background: This study was designed to assess the validity and reliability of the designed sexual, behavioral abstinence, and avoidance of high-risk situation questionnaire (SBAHAQ), with an aim to construct an appropriate development tool in the Iranian population. Materials and Methods: A descriptive–analytic study was conducted among female undergraduate students of Tehran University, who were selected through cluster random sampling. After reviewing the questionnaires and investigating face and content validity, internal consistency of the questionnaire was assessed by Cronbach's alpha. Explanatory and confirmatory factor analysis was conducted using SPSS and AMOS 16 Software, respectively. Results: The sample consisted of 348 female university students with a mean age of 20.69 ± 1.63 years. The content validity ratio (CVR) coefficient was 0.85 and the reliability of each section of the questionnaire was as follows: Perceived benefit (PB; 0.87), behavioral intention (BI; 0.77), and self-efficacy (SE; 0.85) (Cronbach's alpha totally was 0.83). Explanatory factor analysis showed three factors, including SE, PB, and BI, with the total variance of 61% and Kaiser–Meyer–Olkin (KMO) index of 88%. These factors were also confirmed by confirmatory factor analysis [adjusted goodness of fitness index (AGFI) = 0.939, root mean square error of approximation (RMSEA) = 0.039]. Conclusion: This study showed the designed questionnaire provided adequate construct validity and reliability, and could be adequately used to measure sexual abstinence and avoidance of high-risk situations among female students. PMID:24741650

  7. Reliability of different methodologies of infrared image analysis of myofascial trigger points in the upper trapezius muscle

    PubMed Central

    Dibai-Filho, Almir V.; Guirro, Elaine C. O.; Ferreira, Vânia T. K.; Brandino, Hugo E.; Vaz, Maíta M. O. L. L.; Guirro, Rinaldo R. J.

    2015-01-01

    BACKGROUND: Infrared thermography is recognized as a viable method for evaluation of subjects with myofascial pain. OBJECTIVE: The aim of the present study was to assess the intra- and inter-rater reliability of infrared image analysis of myofascial trigger points in the upper trapezius muscle. METHOD: A reliability study was conducted with 24 volunteers of both genders (23 females) between 18 and 30 years of age (22.12±2.54), all having cervical pain and presence of active myofascial trigger point in the upper trapezius muscle. Two trained examiners performed analysis of point, line, and area of the infrared images at two different periods with a 1-week interval. The intra-class correlation coefficient (ICC2,1) was used to assess the intra- and inter-rater reliability. RESULTS: With regard to the intra-rater reliability, ICC values were between 0.591 and 0.993, with temperatures between 0.13 and 1.57 °C for values of standard error of measurement (SEM) and between 0.36 and 4.35 °C for the minimal detectable change (MDC). For the inter-rater reliability, ICC ranged from 0.615 to 0.918, with temperatures between 0.43 and 1.22 °C for the SEM and between 1.19 and 3.38 °C for the MDC. CONCLUSION: The methods of infrared image analyses of myofascial trigger points in the upper trapezius muscle employed in the present study are suitable for clinical and research practices. PMID:25993626

  8. Reliability of Wind Speed Data from Satellite Altimeter to Support Wind Turbine Energy

    NASA Astrophysics Data System (ADS)

    Uti, M. N.; Din, A. H. M.; Omar, A. H.

    2017-10-01

    Satellite altimeter has proven itself to be one of the important tool to provide good quality information in oceanographic study. Nowadays, most countries in the world have begun in implementation the wind energy as one of their renewable energy for electric power generation. Many wind speed studies conducted in Malaysia using conventional method and scientific technique such as anemometer and volunteer observing ships (VOS) in order to obtain the wind speed data to support the development of renewable energy. However, there are some limitations regarding to this conventional method such as less coverage for both spatial and temporal and less continuity in data sharing by VOS members. Thus, the aim of this research is to determine the reliability of wind speed data by using multi-mission satellite altimeter to support wind energy potential in Malaysia seas. Therefore, the wind speed data are derived from nine types of satellite altimeter starting from year 1993 until 2016. Then, to validate the reliability of wind speed data from satellite altimeter, a comparison of wind speed data form ground-truth buoy that located at Sabah and Sarawak is conducted. The validation is carried out in terms of the correlation, the root mean square error (RMSE) calculation and satellite track analysis. As a result, both techniques showing a good correlation with value positive 0.7976 and 0.6148 for point located at Sabah and Sarawak Sea, respectively. It can be concluded that a step towards the reliability of wind speed data by using multi-mission satellite altimeter can be achieved to support renewable energy.

  9. Dynamic MRI to quantify musculoskeletal motion: A systematic review of concurrent validity and reliability, and perspectives for evaluation of musculoskeletal disorders

    PubMed Central

    Lempereur, Mathieu; Lelievre, Mathieu; Burdin, Valérie; Ben Salem, Douraied; Brochard, Sylvain

    2017-01-01

    Purpose To report evidence for the concurrent validity and reliability of dynamic MRI techniques to evaluate in vivo joint and muscle mechanics, and to propose recommendations for their use in the assessment of normal and impaired musculoskeletal function. Materials and methods The search was conducted on articles published in Web of science, PubMed, Scopus, Academic search Premier, and Cochrane Library between 1990 and August 2017. Studies that reported the concurrent validity and/or reliability of dynamic MRI techniques for in vivo evaluation of joint or muscle mechanics were included after assessment by two independent reviewers. Selected articles were assessed using an adapted quality assessment tool and a data extraction process. Results for concurrent validity and reliability were categorized as poor, moderate, or excellent. Results Twenty articles fulfilled the inclusion criteria with a mean quality assessment score of 66% (±10.4%). Concurrent validity and/or reliability of eight dynamic MRI techniques were reported, with the knee being the most evaluated joint (seven studies). Moderate to excellent concurrent validity and reliability were reported for seven out of eight dynamic MRI techniques. Cine phase contrast and real-time MRI appeared to be the most valid and reliable techniques to evaluate joint motion, and spin tag for muscle motion. Conclusion Dynamic MRI techniques are promising for the in vivo evaluation of musculoskeletal mechanics; however results should be evaluated with caution since validity and reliability have not been determined for all joints and muscles, nor for many pathological conditions. PMID:29232401

  10. Reliable assessment of general surgeons' non-technical skills based on video-recordings of patient simulated scenarios.

    PubMed

    Spanager, Lene; Beier-Holgersen, Randi; Dieckmann, Peter; Konge, Lars; Rosenberg, Jacob; Oestergaard, Doris

    2013-11-01

    Nontechnical skills are essential for safe and efficient surgery. The aim of this study was to evaluate the reliability of an assessment tool for surgeons' nontechnical skills, Non-Technical Skills for Surgeons dk (NOTSSdk), and the effect of rater training. A 1-day course was conducted for 15 general surgeons in which they rated surgeons' nontechnical skills in 9 video recordings of scenarios simulating real intraoperative situations. Data were gathered from 2 sessions separated by a 4-hour training session. Interrater reliability was high for both pretraining ratings (Cronbach's α = .97) and posttraining ratings (Cronbach's α = .98). There was no statistically significant development in assessment skills. The D study showed that 2 untrained raters or 1 trained rater was needed to obtain generalizability coefficients >.80. The high pretraining interrater reliability indicates that videos were easy to rate and Non-Technical Skills for Surgeons dk easy to use. This implies that Non-Technical Skills for Surgeons dk (NOTSSdk) could be an important tool in surgical training, potentially improving safety and quality for surgical patients. Copyright © 2013 Elsevier Inc. All rights reserved.

  11. The inter-rater reliability test of the modified Morse Fall Scale among patients ≥ 55 years old in an acute care hospital in Singapore.

    PubMed

    Tang, Wing Sze; Chow, Yeow Leng; Koh, Serena Siew Lin

    2014-02-01

    A prospective, descriptive study was conducted in an acute care hospital in Singapore to determine the inter-rater reliability of the modified Morse Fall Scale by evaluating the degrees of agreement on the ratings of the individual items and overall score between the 'gold standard' assessor and the facility assessors. One hundred and forty-two subjects were recruited during the 1.5 month data collection period. The simple and weighted κ-values were all > 0.8 except for the item 'effects of medications' (κ and κw  = 0.63), and the correlation coefficient (rs  = 0.89) was significantly high at a significance level of < 0.001. The modified Morse Fall Scale was shown to be a reliable fall risk assessment tool having a relative high inter-rater reliability level for the overall score and individual items. This study provides evidence-based psychometric support for the clinical application of this tool. © 2013 Wiley Publishing Asia Pty Ltd.

  12. Elementary School Student Burnout Scale for Grades 6-8: A Study of Validity and Reliability

    ERIC Educational Resources Information Center

    Aypay, Ayse

    2011-01-01

    The purpose of this study is to develop an "Elementary School Student Burnout Scale for Grades 6-8". The study group included 691 students out of 10 schools in Eskisehir. Both Exploratory Factor Analysis and Confirmatory Factor Analysis were conducted on the data (Burnout stem from school activities, burnout stem from family, feeling of…

  13. A Perception Scale on the Use of Webquests in Mathematics Teaching: A Study of Scale Development

    ERIC Educational Resources Information Center

    Demir, Mevhibe Kobak; Gür, Hülya

    2016-01-01

    This study was aimed to develop a valid and reliable perception scale in order to determine the perceptions of pre-service teachers towards the use of WebQuest in mathematics teaching. The study was conducted with 115 junior and senior pre-service teachers at Balikesir University's Faculty of Education, Computer Education and Instructional…

  14. Developing the Attitude Scale for Islamic Law Lesson

    ERIC Educational Resources Information Center

    Ersoy, Mustafa; Izci, Eyüp

    2017-01-01

    This study was conducted for the purpose of developing an attitude scale in order to be able to measure the attitudes of students towards Islamic Law Lesson in a valid and reliable way. The sampling of the study consisted of 198 students who studied at 4th Grade at Cumhuriyet University, Faculty of Theology, and who answered the measurement scale.…

  15. Examining the Psychometric Properties of Acceptance Scale for Kindergarten-Revised (ASK-R) in Turkish

    ERIC Educational Resources Information Center

    Ersan, Deniz Tekin; Ata, Seda; Kaya, Sinem

    2017-01-01

    The aim of this study is to investigate the applicability of ASK-R among Turkish pre-school children and determine the psychometric properties (validity and reliability) of this scale. This study was conducted with 167 students from different pre-schools in Mugla. Within the aim of the study, three different methods were set down in order to…

  16. An Investigation of the Generalizability of Medical School Grades.

    PubMed

    Kreiter, Clarence D; Ferguson, Kristi J

    2016-01-01

    Construct/Background: Medical school grades are currently unstandardized, and their level of reliability is unknown. This means their usefulness for reporting on student achievement is also not well documented. This study investigates grade reliability within 1 medical school. Generalizability analyses are conducted on grades awarded. Grades from didactic and clerkship-based courses were treated as 2 levels of a fixed facet within a univariate mixed model. Grades from within the 2 levels (didactic and clerkship) were also entered in a multivariate generalizability study. Grades from didactic courses were shown to produce a highly reliable mean score (G = .79) when averaged over as few as 5 courses. Although the universe score correlation between didactic and clerkship courses was high (r = .80), the clerkship courses required almost twice as many grades to reach a comparable level of reliability. When grades were converted to a Pass/Fail metric, almost all information contained in the grades was lost. Although it has been suggested that the imprecision of medical school grades precludes their use as a reliable indicator of student achievement, these results suggest otherwise. While it is true that a Pass/Fail system of grading provides very little information about a student's level of performance, a multi-tiered grading system was shown to be a highly reliable indicator of student achievement within the medical school. Although grades awarded during the first 2 didactic years appear to be more reliable than clerkship grades, both yield useful information about student performance within the medical college.

  17. Evaluation of tools used to measure calcium and/or dairy consumption in children and adolescents.

    PubMed

    Magarey, Anthea; Yaxley, Alison; Markow, Kylie; Baulderstone, Lauren; Miller, Michelle

    2014-08-01

    To identify and critique tools that assess Ca and/or dairy intake in children to ascertain the most accurate and reliable tools available. A systematic review of the literature was conducted using defined inclusion and exclusion criteria. Articles were included on the basis that they reported on a tool measuring Ca and/or dairy intake in children in Western countries and reported on originally developed tools or tested the validity or reliability of existing tools. Defined criteria for reporting reliability and validity properties were applied. Studies in Western countries. Children. Eighteen papers reporting on two tools that assessed dairy intake, ten that assessed Ca intake and five that assessed both dairy and Ca were identified. An examination of tool testing revealed high reliance on lower-order tests such as correlation and failure to differentiate between statistical and clinically meaningful significance. Only half of the tools were tested for reliability and results indicated that only one Ca tool and one dairy tool were reliable. Validation studies showed acceptable levels of agreement (<100 mg difference) and/or sensitivity (62-83 %) and specificity (55-77 %) in three Ca tools. With reference to the testing methodology and results, no tools were considered both valid and reliable for the assessment of dairy intake and only one tool proved valid and reliable for the assessment of Ca intake. These results clearly indicate the need for development and rigorous testing of tools to assess Ca and/or dairy intake in children and adolescents.

  18. Conceptual and measurement issues in early parenting practices research: an epidemiologic perspective.

    PubMed

    Walker, Lorraine O; Kirby, Russell S

    2010-11-01

    Early parenting practices are significant to public health because of their linkages to child health outcomes. This paper focuses on the current state of the science regarding conceptual frameworks that incorporate early parenting practices in epidemiologic research and evidence supporting reliability and validity of self-report measures of such practices. Guided by a provisional definition of early parenting practices, literature searches were conducted using PubMed and Sociological Abstracts. Twenty-five published studies that included parent-report measures of early parenting practices met inclusion criteria. Findings on conceptual frameworks were analyzed qualitatively, whereas evidence of reliability and validity were organized into four domains (safety, feeding and oral health, development promotion, and discipline) and summarized in tabular form. Quantitative estimates of measures of reliability and validity were extracted, where available. We found two frameworks incorporating early parenting: one a program theory and the other a predictive model. We found no reported evidence of the reliability or validity of parent-report measures of safety or feeding and oral health practices. Evidence for reliability and validity were reported with greater frequency for development promotion and discipline practices, but report of the most pertinent type of reliability estimation, test-retest reliability, was rare. Failure to examine associations of early parenting practices with any child outcomes within most studies resulted in missed opportunities to indirectly estimate validity of parenting practice measures. Stronger evidence concerning specific measurement properties of early parenting practices is important to advancing maternal-child research, surveillance, and practice.

  19. Estimating functional cognition in older adults using observational assessments of task performance in complex everyday activities: A systematic review and evaluation of measurement properties.

    PubMed

    Wesson, Jacqueline; Clemson, Lindy; Brodaty, Henry; Reppermund, Simone

    2016-09-01

    Functional cognition is a relatively new concept in assessment of older adults with mild cognitive impairment or dementia. Instruments need to be reliable and valid, hence we conducted a systematic review of observational assessments of task performance used to estimate functional cognition in this population. Two separate database searches were conducted: firstly to identify instruments; and secondly to identify studies reporting on the psychometric properties of the instruments. Studies were analysed using a published checklist and their quality reviewed according to specific published criteria. Clinical utility was reviewed and the information formulated into a best evidence synthesis. We found 21 instruments and included 58 studies reporting on measurement properties. The majority of studies were rated as being of fair methodological quality and the range of properties investigated was restricted. Most instruments had studies reporting on construct validity (hypothesis testing), none on content validity and there were few studies reporting on reliability. Overall the evidence on psychometric properties is lacking and there is an urgent need for further evaluation of instruments. Copyright © 2016 Elsevier Ltd. All rights reserved.

  20. Reliability and validity of clinical tests to assess the anatomical integrity of the cervical spine in adults with neck pain and its associated disorders: Part 1-A systematic review from the Cervical Assessment and Diagnosis Research Evaluation (CADRE) Collaboration.

    PubMed

    Lemeunier, Nadège; da Silva-Oolup, S; Chow, N; Southerst, D; Carroll, L; Wong, J J; Shearer, H; Mastragostino, P; Cox, J; Côté, E; Murnaghan, K; Sutton, D; Côté, P

    2017-09-01

    To determine the reliability and validity of clinical tests to assess the anatomical integrity of the cervical spine in adults with neck pain and its associated disorders. We updated the systematic review of the 2000-2010 Bone and Joint Decade Task Force on Neck Pain and its Associated Disorders. We also searched the literature to identify studies on the reliability and validity of Doppler velocimetry for the evaluation of cervical arteries. Two independent reviewers screened and critically appraised studies. We conducted a best evidence synthesis of low risk of bias studies and ranked the phases of investigations using the classification proposed by Sackett and Haynes. We screened 9022 articles and critically appraised 8 studies; all 8 studies had low risk of bias (three reliability and five validity Phase II-III studies). Preliminary evidence suggests that the extension-rotation test may be reliable and has adequate validity to rule out pain arising from facet joints. The evidence suggests variable reliability and preliminary validity for the evaluation of cervical radiculopathy including neurological examination (manual motor testing, dermatomal sensory testing, deep tendon reflexes, and pathological reflex testing), Spurling's and the upper limb neurodynamic tests. No evidence was found for doppler velocimetry. Little evidence exists to support the use of clinical tests to evaluate the anatomical integrity of the cervical spine in adults with neck pain and its associated disorders. We found preliminary evidence to support the use of the extension-rotation test, neurological examination, Spurling's and the upper limb neurodynamic tests.

  1. Test-retest reliability of muscle fiber conduction velocity and fractal dimension of surface EMG during isometric contractions.

    PubMed

    Beretta-Piccoli, Matteo; D'Antona, Giuseppe; Zampella, Cristian; Barbero, Marco; Clijsen, Ron; Cescon, Corrado

    2017-04-01

    The aim of this study was to determine the test-retest reliability of muscle fiber conduction velocity (CV) and fractal dimension (FD) obtained from multichannel surface electromyographic (sEMG) recordings. Forty healthy recreationally active subjects (20 men and 20 women) performed two elbow flexions on two trials with a 1 week interval. The first was a 20% maximal voluntary contraction (MVC) of 120 s, and the second at 60% MVC held until exhaustion. sEMG signals were detected from the biceps brachii, using bi-dimensional arrays. Initial values and slope of CV and FD were used for the reliability analysis. The intraclass correlation coefficient (ICC) values for the isometric contraction at 20% MVC were (-0.09) and 0.67 for CV and FD respectively; whereas the ICC values at 60% MVC were 0.78 and 0.82 for CV and FD respectively. The Bland Altman plots for the two isometric contractions showed a mean difference close to zero, with no evident outliers between the repeated measurements: at 20% MVC 0.001 53 for FD and  -0.0277 for CV, and at 60% MVC 0.006 66 for FD and 0.009 07 for CV. Overall, our findings suggest that during isometric fatiguing contractions, CV and FD slopes are reliable variables, with potential application in clinical populations.

  2. Robust hard-solder packaging of conduction cooled laser diode bars

    NASA Astrophysics Data System (ADS)

    Schleuning, David; Griffin, Mike; James, Phillip; McNulty, John; Mendoza, Dan; Morales, John; Nabors, David; Peters, Mike; Zhou, Hailong; Reed, Murray

    2007-02-01

    We present the reliability of high-power laser diodes utilizing hard solder (AuSn) on a conduction-cooled package (HCCP). We present results of 50 W hard-pulse operation at 8xx nm and demonstrate a reliability of MTTF > 27 khrs (90% CL), which is an order of magnitude improvement over traditional packaging. We also present results at 9xx nm with a reliability of MTTF >17 khrs (90% CL) at 75 W. We discuss finite element analysis (FEA) modeling and time dependent temperature measurements combined with experimental life-test data to quantify true hard-pulse operation. We also discuss FEA and measured stress profiles across laser bars comparing soft and hard solder packaging.

  3. The Prosocial and Antisocial Behaviour in Sport Scale: further evidence for construct validity and reliability.

    PubMed

    Kavussanu, Maria; Stanger, Nicholas; Boardley, Ian D

    2013-01-01

    The purpose of this research was to provide further evidence for the construct validity (i.e., convergent, concurrent, and discriminant validity) of the Prosocial and Antisocial Behaviour in Sport Scale (PABSS), an instrument that has four subscales measuring prosocial and antisocial behaviour toward teammates and opponents. We also investigated test-retest reliability and stability of the PABSS. We conducted three studies using athletes from a variety of team sports. In Study 1, participants (N = 129) completed the PABSS and measures of physical and verbal aggression, hostility, anger, moral identity, and empathy; a sub-sample (n = 111) also completed the PABSS one week later. In Study 2, in addition to the PABSS, participants (N = 89) completed measures of competitive aggressiveness and anger, moral attitudes, moral disengagement, goal orientation, and anxiety. In Study 3, participants (N = 307) completed the PABSS and a measure of social goals. Across the three studies, the four subscales evidenced the hypothesised relationships with a number of variables. Correlations were large between the two antisocial behaviours and small between the two prosocial behaviours. Overall, the findings supported the convergent, concurrent, and discriminant validity of the scale, provided evidence for its test-retest reliability and stability, and suggest that the instrument is a valid and reliable measure of prosocial and antisocial behaviour in sport.

  4. Nutrition Environment Measures Survey in stores (NEMS-S): development and evaluation.

    PubMed

    Glanz, Karen; Sallis, James F; Saelens, Brian E; Frank, Lawrence D

    2007-04-01

    Eating, or nutrition, environments are believed to contribute to obesity and chronic diseases. There is a need for valid, reliable measures of nutrition environments. This article reports on the development and evaluation of measures of nutrition environments in retail food stores. The Nutrition Environment Measures Study developed observational measures of the nutrition environment within retail food stores (NEMS-S) to assess availability of healthy options, price, and quality. After pretesting, measures were completed by independent raters to evaluate inter-rater reliability and across two occasions to assess test-retest reliability in grocery and convenience stores in four neighborhoods differing on income and community design in the Atlanta metropolitan area. Data were collected and analyzed in 2004 and 2005. Ten food categories (e.g., fruits) or indicator food items (e.g., ground beef) were evaluated in 85 stores. Inter-rater reliability and test-retest reliability of availability were high: inter-rater reliability kappas were 0.84 to 1.00, and test-retest reliabilities were .73 to 1.00. Inter-rater reliability for quality across fresh produce was moderate (kappas, 0.44 to 1.00). Healthier options were higher priced for hot dogs, lean ground beef, and baked chips. More healthful options were available in grocery than convenience stores and in stores in higher income neighborhoods. The NEMS-S tool was found to have a high degree of inter-rater and test-retest reliability, and to reveal significant differences across store types and neighborhoods of high and low socioeconomic status. These observational measures of nutrition environments can be applied in multilevel studies of community nutrition, and can inform new approaches to conducting and evaluating nutrition interventions.

  5. Manufacture of a UO2-Based Nuclear Fuel with Improved Thermal Conductivity with the Addition of BeO

    NASA Astrophysics Data System (ADS)

    Garcia, Chad B.; Brito, Ryan A.; Ortega, Luis H.; Malone, James P.; McDeavitt, Sean M.

    2017-12-01

    The low thermal conductivity of oxide nuclear fuels is a performance-limiting parameter. Enhancing this property may provide a contribution toward establishing accident-tolerant fuel forms. In this study, the thermal conductivity of UO2 was increased through the fabrication of ceramic-ceramic composite forms with UO2 containing a continuous BeO matrix. Fuel with a higher thermal conductivity will have reduced thermal gradients and lower centerline temperatures in the fuel pin. Lower operational temperatures will reduce fission gas release and reduce fuel restructuring. Additions of BeO were made to UO2 fuel pellets in 2.5, 5, 7.5, and 10 vol pct concentrations with the goals of establishing reliable lab-scale processing procedures, minimizing porosity, and maximizing thermal conductivity. The microstructure was characterized with electron probe microanalysis, and the thermal properties were assessed by light flash analysis and differential scanning calorimetry. Reliable, high-density samples were prepared using compaction pressure between 200 and 225 MPa and sintering times between 4 and 6 hours. It was found that the thermal conductivity of UO2 improved approximately 10 pct for each 1 vol pct BeO added over the measured temperature range 298.15 K to 523.15 K (25 °C to 250 °C) with the maximum observed improvement being ˜ 100 pct, or doubled, at 10 vol pct BeO.

  6. Reliability of risk-adjusted outcomes for profiling hospital surgical quality.

    PubMed

    Krell, Robert W; Hozain, Ahmed; Kao, Lillian S; Dimick, Justin B

    2014-05-01

    Quality improvement platforms commonly use risk-adjusted morbidity and mortality to profile hospital performance. However, given small hospital caseloads and low event rates for some procedures, it is unclear whether these outcomes reliably reflect hospital performance. To determine the reliability of risk-adjusted morbidity and mortality for hospital performance profiling using clinical registry data. A retrospective cohort study was conducted using data from the American College of Surgeons National Surgical Quality Improvement Program, 2009. Participants included all patients (N = 55,466) who underwent colon resection, pancreatic resection, laparoscopic gastric bypass, ventral hernia repair, abdominal aortic aneurysm repair, and lower extremity bypass. Outcomes included risk-adjusted overall morbidity, severe morbidity, and mortality. We assessed reliability (0-1 scale: 0, completely unreliable; and 1, perfectly reliable) for all 3 outcomes. We also quantified the number of hospitals meeting minimum acceptable reliability thresholds (>0.70, good reliability; and >0.50, fair reliability) for each outcome. For overall morbidity, the most common outcome studied, the mean reliability depended on sample size (ie, how high the hospital caseload was) and the event rate (ie, how frequently the outcome occurred). For example, mean reliability for overall morbidity was low for abdominal aortic aneurysm repair (reliability, 0.29; sample size, 25 cases per year; and event rate, 18.3%). In contrast, mean reliability for overall morbidity was higher for colon resection (reliability, 0.61; sample size, 114 cases per year; and event rate, 26.8%). Colon resection (37.7% of hospitals), pancreatic resection (7.1% of hospitals), and laparoscopic gastric bypass (11.5% of hospitals) were the only procedures for which any hospitals met a reliability threshold of 0.70 for overall morbidity. Because severe morbidity and mortality are less frequent outcomes, their mean reliability was lower, and even fewer hospitals met the thresholds for minimum reliability. Most commonly reported outcome measures have low reliability for differentiating hospital performance. This is especially important for clinical registries that sample rather than collect 100% of cases, which can limit hospital case accrual. Eliminating sampling to achieve the highest possible caseloads, adjusting for reliability, and using advanced modeling strategies (eg, hierarchical modeling) are necessary for clinical registries to increase their benchmarking reliability.

  7. Making literature reviews more reliable through application of lessons from systematic reviews.

    PubMed

    Haddaway, N R; Woodcock, P; Macura, B; Collins, A

    2015-12-01

    Review articles can provide valuable summaries of the ever-increasing volume of primary research in conservation biology. Where findings may influence important resource-allocation decisions in policy or practice, there is a need for a high degree of reliability when reviewing evidence. However, traditional literature reviews are susceptible to a number of biases during the identification, selection, and synthesis of included studies (e.g., publication bias, selection bias, and vote counting). Systematic reviews, pioneered in medicine and translated into conservation in 2006, address these issues through a strict methodology that aims to maximize transparency, objectivity, and repeatability. Systematic reviews will always be the gold standard for reliable synthesis of evidence. However, traditional literature reviews remain popular and will continue to be valuable where systematic reviews are not feasible. Where traditional reviews are used, lessons can be taken from systematic reviews and applied to traditional reviews in order to increase their reliability. Certain key aspects of systematic review methods that can be used in a context-specific manner in traditional reviews include focusing on mitigating bias; increasing transparency, consistency, and objectivity, and critically appraising the evidence and avoiding vote counting. In situations where conducting a full systematic review is not feasible, the proposed approach to reviewing evidence in a more systematic way can substantially improve the reliability of review findings, providing a time- and resource-efficient means of maximizing the value of traditional reviews. These methods are aimed particularly at those conducting literature reviews where systematic review is not feasible, for example, for graduate students, single reviewers, or small organizations. © 2015 Society for Conservation Biology.

  8. Korean version of the Revised Caregiving Appraisal Scale: a translation and validation study.

    PubMed

    Lee, JuHee; Friedmann, Erika; Picot, Sandra J; Thomas, Sue Ann; Kim, Cho Ja

    2007-08-01

    This paper is a report of a study to examine the reliability and validity of a Korean version of the Revised Caregiving Appraisal Scale with Korean caregivers of older stroke survivors. The Revised Caregiving Appraisal Scale was developed in the United States of America for an American English-speaking population to measure primary caregivers' appraisals of potential stressors and the efficacy of their coping efforts related to caregiving experiences. Using the back-translation method, the instrument was translated into Korean. The Korean version of the Revised Caregiving Appraisal Scale was self-administered by 147 primary family caregivers recruited from three outpatient clinics and two home health agencies in Korea. The study was conducted in 2005. In this sample, Cronbach's alpha for the total scale was 0.86. Reliability coefficients for each of the five subscales ranged from 0.40 to 0.85. Two subscales, burden and satisfaction, showed good reliability; one subscale, impact, showed marginally acceptable reliability; two subscales, mastery and demand, had low reliability. Principal components factor analysis of the Korean version of the Revised Caregiving Appraisal Scale yielded six factors. Except for the mastery domain, which was divided into two factors, the other factors were similar to those in the original scale. The Korean version of the Revised Caregiving Appraisal Scale had adequate reliability and validity in a sample of Korean caregivers of stroke survivors. It can be used to assess the impact of caregiving and interventions on Korean caregiver attitudes. Further studies are needed with different categories of caregiver.

  9. Reliability analysis of the objective structured clinical examination using generalizability theory.

    PubMed

    Trejo-Mejía, Juan Andrés; Sánchez-Mendiola, Melchor; Méndez-Ramírez, Ignacio; Martínez-González, Adrián

    2016-01-01

    The objective structured clinical examination (OSCE) is a widely used method for assessing clinical competence in health sciences education. Studies using this method have shown evidence of validity and reliability. There are no published studies of OSCE reliability measurement with generalizability theory (G-theory) in Latin America. The aims of this study were to assess the reliability of an OSCE in medical students using G-theory and explore its usefulness for quality improvement. An observational cross-sectional study was conducted at National Autonomous University of Mexico (UNAM) Faculty of Medicine in Mexico City. A total of 278 fifth-year medical students were assessed with an 18-station OSCE in a summative end-of-career final examination. There were four exam versions. G-theory with a crossover random effects design was used to identify the main sources of variance. Examiners, standardized patients, and cases were considered as a single facet of analysis. The exam was applied to 278 medical students. The OSCE had a generalizability coefficient of 0.93. The major components of variance were stations, students, and residual error. The sites and the versions of the tests had minimum variance. Our study achieved a G coefficient similar to that found in other reports, which is acceptable for summative tests. G-theory allows the estimation of the magnitude of multiple sources of error and helps decision makers to determine the number of stations, test versions, and examiners needed to obtain reliable measurements.

  10. Reliability analysis of the objective structured clinical examination using generalizability theory.

    PubMed

    Trejo-Mejía, Juan Andrés; Sánchez-Mendiola, Melchor; Méndez-Ramírez, Ignacio; Martínez-González, Adrián

    2016-01-01

    Background The objective structured clinical examination (OSCE) is a widely used method for assessing clinical competence in health sciences education. Studies using this method have shown evidence of validity and reliability. There are no published studies of OSCE reliability measurement with generalizability theory (G-theory) in Latin America. The aims of this study were to assess the reliability of an OSCE in medical students using G-theory and explore its usefulness for quality improvement. Methods An observational cross-sectional study was conducted at National Autonomous University of Mexico (UNAM) Faculty of Medicine in Mexico City. A total of 278 fifth-year medical students were assessed with an 18-station OSCE in a summative end-of-career final examination. There were four exam versions. G-theory with a crossover random effects design was used to identify the main sources of variance. Examiners, standardized patients, and cases were considered as a single facet of analysis. Results The exam was applied to 278 medical students. The OSCE had a generalizability coefficient of 0.93. The major components of variance were stations, students, and residual error. The sites and the versions of the tests had minimum variance. Conclusions Our study achieved a G coefficient similar to that found in other reports, which is acceptable for summative tests. G-theory allows the estimation of the magnitude of multiple sources of error and helps decision makers to determine the number of stations, test versions, and examiners needed to obtain reliable measurements.

  11. Illinois high-speed rail four-quadrant gate reliability assessment

    DOT National Transportation Integrated Search

    2009-10-01

    The Federal Railroad Administration (FRA) tasked the John A. Volpe National Transportation Systems Center (Volpe Center) to conduct a reliability analysis of the four-quadrant gate/vehicle detection equipment installed on the future high-speed rail (...

  12. Reliability, reference values and predictor variables of the ulnar sensory nerve in disease free adults.

    PubMed

    Ruediger, T M; Allison, S C; Moore, J M; Wainner, R S

    2014-09-01

    The purposes of this descriptive and exploratory study were to examine electrophysiological measures of ulnar sensory nerve function in disease free adults to determine reliability, determine reference values computed with appropriate statistical methods, and examine predictive ability of anthropometric variables. Antidromic sensory nerve conduction studies of the ulnar nerve using surface electrodes were performed on 100 volunteers. Reference values were computed from optimally transformed data. Reliability was computed from 30 subjects. Multiple linear regression models were constructed from four predictor variables. Reliability was greater than 0.85 for all paired measures. Responses were elicited in all subjects; reference values for sensory nerve action potential (SNAP) amplitude from above elbow stimulation are 3.3 μV and decrement across-elbow less than 46%. No single predictor variable accounted for more than 15% of the variance in the response. Electrophysiologic measures of the ulnar sensory nerve are reliable. Absent SNAP responses are inconsistent with disease free individuals. Reference values recommended in this report are based on appropriate transformations of non-normally distributed data. No strong statistical model of prediction could be derived from the limited set of predictor variables. Reliability analyses combined with relatively low level of measurement error suggest that ulnar sensory reference values may be used with confidence. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  13. The precision and reliability evaluation of 3-dimensional printed damaged bone and prosthesis models by stereo lithography appearance

    PubMed Central

    Zou, Yun; Han, Qing; Weng, Xisheng; Zou, Yongwei; Yang, Yingying; Zhang, Kesong; Yang, Kerong; Xu, Xiaolin; Wang, Chenyu; Qin, Yanguo; Wang, Jincheng

    2018-01-01

    Abstract Recently, clinical application of 3D printed model was increasing. However, there was no systemic study for confirming the precision and reliability of 3D printed model. Some senior clinical doctors mistrusted its reliability in clinical application. The purpose of this study was to evaluate the precision and reliability of stereolithography appearance (SLA) 3D printed model. Some related parameters were selected to research the reliability of SLA 3D printed model. The computed tomography (CT) data of bone/prosthesis and model were collected and 3D reconstructed. Some anatomical parameters were measured and statistical analysis was performed; the intraclass correlation coefficient (ICC) was used to was used to evaluate the similarity between the model and real bone/prosthesis. the absolute difference (mm) and relative difference (%) were conducted. For prosthesis model, the 3-dimensional error was measured. There was no significant difference in the anatomical parameters except max height (MH) of long bone. All the ICCs were greater than 0.990. The maximum absolute and relative difference were 0.45 mm and 1.10%; The 3-dimensional error analysis showed that positive/minus distance were 0.273 mm/0.237 mm. The application of SLA 3D printed model in diagnosis and treatment process of complex orthopedic disease was reliable and precise. PMID:29419675

  14. The precision and reliability evaluation of 3-dimensional printed damaged bone and prosthesis models by stereo lithography appearance.

    PubMed

    Zou, Yun; Han, Qing; Weng, Xisheng; Zou, Yongwei; Yang, Yingying; Zhang, Kesong; Yang, Kerong; Xu, Xiaolin; Wang, Chenyu; Qin, Yanguo; Wang, Jincheng

    2018-02-01

    Recently, clinical application of 3D printed model was increasing. However, there was no systemic study for confirming the precision and reliability of 3D printed model. Some senior clinical doctors mistrusted its reliability in clinical application. The purpose of this study was to evaluate the precision and reliability of stereolithography appearance (SLA) 3D printed model.Some related parameters were selected to research the reliability of SLA 3D printed model. The computed tomography (CT) data of bone/prosthesis and model were collected and 3D reconstructed. Some anatomical parameters were measured and statistical analysis was performed; the intraclass correlation coefficient (ICC) was used to was used to evaluate the similarity between the model and real bone/prosthesis. the absolute difference (mm) and relative difference (%) were conducted. For prosthesis model, the 3-dimensional error was measured.There was no significant difference in the anatomical parameters except max height (MH) of long bone. All the ICCs were greater than 0.990. The maximum absolute and relative difference were 0.45 mm and 1.10%; The 3-dimensional error analysis showed that positive/minus distance were 0.273 mm/0.237 mm.The application of SLA 3D printed model in diagnosis and treatment process of complex orthopedic disease was reliable and precise.

  15. Reliability of Space-Shuttle Pressure Vessels with Random Batch Effects

    NASA Technical Reports Server (NTRS)

    Feiveson, Alan H.; Kulkarni, Pandurang M.

    2000-01-01

    In this article we revisit the problem of estimating the joint reliability against failure by stress rupture of a group of fiber-wrapped pressure vessels used on Space-Shuttle missions. The available test data were obtained from an experiment conducted at the U.S. Department of Energy Lawrence Livermore Laboratory (LLL) in which scaled-down vessels were subjected to life testing at four accelerated levels of pressure. We estimate the reliability assuming that both the Shuttle and LLL vessels were chosen at random in a two-stage process from an infinite population with spools of fiber as the primary sampling unit. Two main objectives of this work are: (1) to obtain practical estimates of reliability taking into account random spool effects and (2) to obtain a realistic assessment of estimation accuracy under the random model. Here, reliability is calculated in terms of a 'system' of 22 fiber-wrapped pressure vessels, taking into account typical pressures and exposure times experienced by Shuttle vessels. Comparisons are made with previous studies. The main conclusion of this study is that, although point estimates of reliability are still in the 'comfort zone,' it is advisable to plan for replacement of the pressure vessels well before the expected Lifetime of 100 missions per Shuttle Orbiter. Under a random-spool model, there is simply not enough information in the LLL data to provide reasonable assurance that such replacement would not be necessary.

  16. The Reliability and Validity of Prostate Cancer Fatalism Inventory in Turkish Language.

    PubMed

    Aydoğdu, Nihal Gördes; Çapık, Cantürk; Ersin, Fatma; Kissal, Aygul; Bahar, Zuhal

    2017-10-01

    This study aimed to conduct the reliability and validity study of the Prostate Cancer Fatalism Inventory in Turkish language. The study carried out in methodological type and consisted of 171 men. The ages of the participants ranged between 40 and 82. The content validity index was determined to be 0.80, Kaiser-Meyer-Olkin value 0.825, Bartlett's test X 2  = 750.779 and p = 0.000. Then the principal component analysis was applied to the 15-item inventory. The inventory consisted of one dimension, and the load factors were over 0.30 for all items. The explained variance of the inventory was found 33.3 %. The Kuder-Richardson-20 coefficient was determined to be 0.849 and the item-total correlations ranged between 0.335 and 0.627. The Prostate Cancer Fatalism Inventory was a reliable and valid measurement tool in Turkish language. Integrating psychological strategies for prostate cancer screening may be required to strengthen the positive effects of nursing education.

  17. Telepsychiatry: assessment of televideo psychiatric interview reliability with present- and next-generation internet infrastructures.

    PubMed

    Yoshino, A; Shigemura, J; Kobayashi, Y; Nomura, S; Shishikura, K; Den, R; Wakisaka, H; Kamata, S; Ashida, H

    2001-09-01

    We assessed the reliability of remote video psychiatric interviews conducted via the internet using narrow and broad bandwidths. Televideo psychiatric interviews conducted with 42 in-patients with chronic schizophrenia using two bandwidths (narrow, 128 kilobits/s; broad, 2 megabits/s) were assessed in terms of agreement with face-to-face interviews in a test-retest fashion. As a control, agreement was assessed between face-to-face interviews. Psychiatric symptoms were rated using the Oxford version of the Brief Psychiatric Rating Scale (BPRS), and agreement between interviews was estimated as the intraclass correlation coefficient (ICC). The ICC was significantly lower in the narrow bandwidth than in the broad bandwidth and the control for both positive symptoms score and total score. While reliability of televideo psychiatric interviews is insufficient using the present narrow-band internet infrastructure, the next generation of infrastructure (broad-band) may permit reliable diagnostic interviews.

  18. Student-to-Student Confirmation in the College Classroom: The Development and Validation of the Student-to-Student Confirmation Scale

    ERIC Educational Resources Information Center

    LaBelle, Sara; Johnson, Zac D.

    2018-01-01

    Three studies were conducted to generate a valid and reliable instrument to measure student-to-student confirmation. Study One (N = 396) sought to establish a factor structure based on previous research. Study Two (N = 396) sought to confirm this factor structure and assess criterion-related validity. Study Three (N = 283) sought to assess…

  19. The Development and Initial Validation of the Work Volition Scale-Student Version

    ERIC Educational Resources Information Center

    Duffy, Ryan D.; Diemer, Matthew A.; Jadidian, Alex

    2012-01-01

    The present study sought to develop and validate an instrument to measure work volition, defined as the perceived capacity to make occupational choices despite constraints, among college students. In Study 1, an exploratory factor analysis was conducted with a large and diverse sample of college students, finding a reliable scale with two factors,…

  20. The Reliability and Validity of a Progress-Monitoring Tool: A Psychometric Examination of the Phonological Awareness Skills of Preschoolers with ASD

    ERIC Educational Resources Information Center

    Martini, Jay R.

    2017-01-01

    The purpose of this study was to conduct a psychometric evaluation the "Sound Beginning" phonological awareness progress monitoring tool. This assessment was used to track emergent literacy skills of preschoolers with autism spectrum disorder who were participating in a randomized trial studying early literacy interventions. Research…

  1. Development, Validity, and Reliability of the Parental Support Scale--Student Version

    ERIC Educational Resources Information Center

    Yazedjian, Ani; Toews, Michelle L.

    2016-01-01

    The purpose of this study was to develop and validate the Parental Support Scale-Student Version (PSS-SV), a measure examining students' perceptions of how their parents supported them as they navigated the college environment. A total of 1,351 students participated in the study. After conducting an exploratory and confirmatory factor analysis,…

  2. Development of Teachers' Attitude Scale towards Science Fair

    ERIC Educational Resources Information Center

    Tortop, Hasan Said

    2013-01-01

    This study was conducted to develop a new scale for measuring teachers' attitude towards science fair. Teacher Attitude Scale towards Science Fair (TASSF) is an inventory made up of 19 items and five dimensions. The study included such stages as literature review, the preparation of the item pool and the reliability and validity analysis. First of…

  3. Evaluating Outcomes of High Fidelity Simulation Curriculum in a Community College Nursing Program

    ERIC Educational Resources Information Center

    Denlea, Gregory Richard

    2017-01-01

    This study took place at a Wake Technical Community College, a multi-campus institution in Raleigh, North Carolina. An evaluation of the return on investment in high fidelity simulation used by an associate degree of nursing program was conducted with valid and reliable instruments. The study demonstrated that comparable student outcomes are…

  4. Methods for assessing the quality of data in public health information systems: a critical review.

    PubMed

    Chen, Hong; Yu, Ping; Hailey, David; Wang, Ning

    2014-01-01

    The quality of data in public health information systems can be ensured by effective data quality assessment. In order to conduct effective data quality assessment, measurable data attributes have to be precisely defined. Then reliable and valid measurement methods for data attributes have to be used to measure each attribute. We conducted a systematic review of data quality assessment methods for public health using major databases and well-known institutional websites. 35 studies were eligible for inclusion in the study. A total of 49 attributes of data quality were identified from the literature. Completeness, accuracy and timeliness were the three most frequently assessed attributes of data quality. Most studies directly examined data values. This is complemented by exploring either data users' perception or documentation quality. However, there are limitations of current data quality assessment methods: a lack of consensus on attributes measured; inconsistent definition of the data quality attributes; a lack of mixed methods for assessing data quality; and inadequate attention to reliability and validity. Removal of these limitations is an opportunity for further improvement.

  5. Subsea pipeline isolation systems: Reliability and costs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Masheder, R.R.

    1995-12-31

    On the night of 6/7 July 1988 a major oil production platform known as Piper Alpha in the UK sector of the North Sea was destroyed by explosion and fire, with the loss of 167 lives. This led to the appointment of Lord Cullen, a senior Scottish Judge, to hold a Public Inquiry into the Piper Alpha Disaster. The Cullen Enquiry Report consisting of 23 chapters set out in 2 volumes, was published on 12 November 1990. One of the important conclusions drawn by Lord Cullen resulted in a recommendation for studies to be conducted to consider ways of improvingmore » the reliability and reducing the costs of SSIVs (Subsea Isolation Valves) so that it is more often reasonably practicable to install them. To address the Cullen recommendations, a joint industry study was conducted by UKOOA (United Kingdom Offshore Operators Association) and the HSE/OSD (Health and Safety Executive Offshore Safety Division) in conjunction with independent consultants. The results of the studies and the conclusions drawn by UKOOA Pipeline Valve Group and the HSE Offshore Safety Division are presented in this paper.« less

  6. Methodological difficulties of conducting agroecological studies from a statistical perspective

    USDA-ARS?s Scientific Manuscript database

    Statistical methods for analysing agroecological data might not be able to help agroecologists to solve all of the current problems concerning crop and animal husbandry, but such methods could well help agroecologists to assess, tackle, and resolve several agroecological issues in a more reliable an...

  7. A Reliability Generalization of the Parental Authority Questionnaire

    ERIC Educational Resources Information Center

    Dean, Lynn M.

    2016-01-01

    How parents interact with their children impacts many crucial facets of children's lives. Over the last 4 decades, researchers have identified four different parenting styles: authoritative, authoritarian, permissive, and disengaged. Hundreds of studies conducted all over the world, have identified correlations between parenting style and many…

  8. Predicting oral relative bioavailability of arsenic in soil from in vitro bioaccessibility

    EPA Science Inventory

    Several investigations have been conducted to develop in vitro bioaccessibility (IVBA) assays that reliably predict in vivo oral relative bioavailability (RBA) of arsenic (As). This study describes a meta-regression model relating soil As RBA and IVBA that is based upon data comb...

  9. Reliability and concurrent validity of the computer workstation checklist.

    PubMed

    Baker, Nancy A; Livengood, Heather; Jacobs, Karen

    2013-01-01

    Self-report checklists are used to assess computer workstation set up, typically by workers not trained in ergonomic assessment or checklist interpretation.Though many checklists exist, few have been evaluated for reliability and validity. This study examined reliability and validity of the Computer Workstation Checklist (CWC) to identify mismatches between workers' self-reported workstation problems. The CWC was completed at baseline and at 1 month to establish reliability. Validity was determined with CWC baseline data compared to an onsite workstation evaluation conducted by an expert in computer workstation assessment. Reliability ranged from fair to near perfect (prevalence-adjusted bias-adjusted kappa, 0.38-0.93); items with the strongest agreement were related to the input device, monitor, computer table, and document holder. The CWC had greater specificity (11 of 16 items) than sensitivity (3 of 16 items). The positive predictive value was greater than the negative predictive value for all questions. The CWC has strong reliability. Sensitivity and specificity suggested workers often indicated no problems with workstation setup when problems existed. The evidence suggests that while the CWC may not be valid when used alone, it may be a suitable adjunct to an ergonomic assessment completed by professionals.

  10. Reliability of Use, Abuse, and Dependence of Four Types of Inhalants in Adolescents and Young Adults

    PubMed Central

    Ridenour, Ty A.; Bray, Bethany C.; Cottler, Linda B.

    2007-01-01

    Inhalants, as a class of drugs, consists of heterogeneous substances that include some of the most dangerous drugs on a per use basis. Research on inhalant abuse has lagged behind other drugs partly because of the need for a diagnostic instrument of different types of inhalants. This study was conducted to obtain reliability estimates for the new Substance Abuse Module DSM-IV inhalants diagnoses for four types of inhalants: aerosols, gases, nitrites, and solvents as well as different diagnostic configurations of inhalant use. Participants were 162 community sample adolescents or young adults (mean age = 20.3 years, SD = 2.4). Two-thirds of the sample was male and 83.3% was Caucasian. Kappas and intraclass correlation coefficients were computed to estimate test-retest reliabilities. Results suggested (a) abuse was more common than dependence (34.6% vs. 12.3%), (b) reliabilities of abuse criteria and diagnosis were good to excellent across subtypes, and (c) reliabilities of dependence criteria and diagnoses were poor to good across subtypes. Alternative configurations of DSM-IV criteria that were consistent with previous research on adolescents provided excellent reliabilities across subtypes of inhalants. Moreover, 11.1% of participants experienced inhalants withdrawal. PMID:17576041

  11. Surveying the factor structure and reliability of the Persian version of the Jefferson Scale of Physician Lifelong Learning (JeffSPLL) in staff of medical sciences.

    PubMed

    Karimi, Fatemeh Zahra; Alesheikh, Aytay; Pakravan, Soheila; Abdollahi, Mahbubeh; Damough, Mozhdeh; Anbaran, Zahra Khosravi; Farahani, Leila Amiri

    2017-10-01

    In medical sciences, commitment to lifelong learning has been expressed as an important element. Today, due to the rapid development of medical information and technology, lifelong learning is critical for safe medical care and development in medical research. JeffSPLL is one of the scales for measuring lifelong learning among the staff of medical sciences that has never been used in Iran. The aim of the present study was to determine the factor structure and reliability of the Persian version of JeffSPLL among Persian-speaking staff of universities of medical sciences in Iran. This study was a cross-sectional study, methodologically, that was conducted in 2012-2013. In this study, 210 staff members of Birjand University of Medical Sciences were selected. Data collection tool was the Persian version of JeffSPLL. To investigate the factor structure of this tool, confirmatory factor analysis was used and to evaluate the model fit, goodness-of-fit indices, root mean square error of approximation (RMSEA), the ratio of chi-square to the degree of freedom associated with it, comparative fit index (CFI), and root mean square residual (RMR) were used. To investigate the reliability of tool, Cronbach's alpha was employed. Data analysis was conducted using LISREL8.8 and SPSS 20 software. Confirmatory factor analysis showed that RMSEA was close to 0.1, and CFI and GFI were close to one. Therefore, four-factor model was appropriate. Cronbach's alpha was 0.92 for the whole tool and it was between 0.82 and 0.89 for subscales. The present study verified the four-factor structure of the 19-item Persian version of JeffSPLL that included professional learning beliefs and motivation, scholarly activities, attention to learning opportunities, and technical skills in information seeking among the staff. In addition, this tool has acceptable reliability. Therefore, it was appropriate to assess lifelong learning in the Persian-speaking staff population.

  12. Assessment of family functioning in Caucasian and Hispanic Americans: reliability, validity, and factor structure of the Family Assessment Device.

    PubMed

    Aarons, Gregory A; McDonald, Elizabeth J; Connelly, Cynthia D; Newton, Rae R

    2007-12-01

    The purpose of this study was to examine the factor structure, reliability, and validity of the Family Assessment Device (FAD) among a national sample of Caucasian and Hispanic American families receiving public sector mental health services. A confirmatory factor analysis conducted to test model fit yielded equivocal findings. With few exceptions, indices of model fit, reliability, and validity were poorer for Hispanic Americans compared with Caucasian Americans. Contrary to our expectation, an exploratory factor analysis did not result in a better fitting model of family functioning. Without stronger evidence supporting a reformulation of the FAD, we recommend against such a course of action. Findings highlight the need for additional research on the role of culture in measurement of family functioning.

  13. Investigation of low glass transition temperature on COTS PEMs reliability

    NASA Technical Reports Server (NTRS)

    Sandor, M.; Agarwal, S.

    2002-01-01

    Many factors influence PEM component reliability.One of the factors that can affect PEM performance and reliability is the glass transition temperature (Tg) and the coefficient of thermal expansion (CTE) of the encapsulant or underfill. JPL/NASA is investigating how the Tg and CTE for PEMs affect device reliability under different temperature and aging conditions. Other issues with Tg are also being investigated. Some preliminary data will be presented on glass transition temperature test results conducted at JPL.

  14. Reliability and validity of the Safe Routes to school parent and student surveys

    PubMed Central

    2011-01-01

    Background The purpose of this study is to assess the reliability and validity of the U.S. National Center for Safe Routes to School's in-class student travel tallies and written parent surveys. Over 65,000 tallies and 374,000 parent surveys have been completed, but no published studies have examined their measurement properties. Methods Students and parents from two Charlotte, NC (USA) elementary schools participated. Tallies were conducted on two consecutive days using a hand-raising protocol; on day two students were also asked to recall the previous days' travel. The recall from day two was compared with day one to assess 24-hour test-retest reliability. Convergent validity was assessed by comparing parent-reports of students' travel mode with student-reports of travel mode. Two-week test-retest reliability of the parent survey was assessed by comparing within-parent responses. Reliability and validity were assessed using kappa statistics. Results A total of 542 students participated in the in-class student travel tally reliability assessment and 262 parent-student dyads participated in the validity assessment. Reliability was high for travel to and from school (kappa > 0.8); convergent validity was lower but still high (kappa > 0.75). There were no differences by student grade level. Two-week test-retest reliability of the parent survey (n = 112) ranged from moderate to very high for objective questions on travel mode and travel times (kappa range: 0.62 - 0.97) but was substantially lower for subjective assessments of barriers to walking to school (kappa range: 0.31 - 0.76). Conclusions The student in-class student travel tally exhibited high reliability and validity at all elementary grades. The parent survey had high reliability on questions related to student travel mode, but lower reliability for attitudinal questions identifying barriers to walking to school. Parent survey design should be improved so that responses clearly indicate issues that influence parental decision making in regards to their children's mode of travel to school. PMID:21651794

  15. Defining physicians' readiness to screen and manage intimate partner violence in Greek primary care settings.

    PubMed

    Papadakaki, Maria; Prokopiadou, Dimitra; Petridou, Eleni; Kogevinas, Manolis; Lionis, Christos

    2012-06-01

    The current article aims to translate the PREMIS (Physician Readiness to Manage Intimate Partner Violence) survey into the Greek language and test its validity and reliability in a sample of primary care physicians. The validation study was conducted in 2010 and involved all the general practitioners serving two adjacent prefectures of Greece (n = 80). Maximum-likelihood factor analysis (MLF) was used to extract key survey factors. The instrument was further assessed for the following psychometric properties: (a) scale reliability, (b) item-specific reliability, (c) test-retest reliability, (d) scale construct validity, and (e) internal predictive validity. The MLF analysis of 23 opinion items revealed a seven-factor solution (preparation, constraint, workplace issues, screening, self-efficacy, alcohol/drugs, victim understanding), which was statistically sound (p = .293). Most of the newly derived scales displayed satisfactory internal consistency (α ≥ .60), high item-specific reliability, strong construct, and internal predictive validity (F = 2.82; p = .004), and high repeatability when retested with 20 individuals (intraclass correlation coefficient [ICC] > .70). The tool was found appropriate to facilitate the identification of competence deficits and the evaluation of training initiatives.

  16. The Effect of Incorrect Reliability Information on Expectations, Perceptions, and Use of Automation.

    PubMed

    Barg-Walkow, Laura H; Rogers, Wendy A

    2016-03-01

    We examined how providing artificially high or low statements about automation reliability affected expectations, perceptions, and use of automation over time. One common method of introducing automation is providing explicit statements about the automation's capabilities. Research is needed to understand how expectations from such introductions affect perceptions and use of automation. Explicit-statement introductions were manipulated to set higher-than (90%), same-as (75%), or lower-than (60%) levels of expectations in a dual-task scenario with 75% reliable automation. Two experiments were conducted to assess expectations, perceptions, compliance, reliance, and task performance over (a) 2 days and (b) 4 days. The baseline assessments showed initial expectations of automation reliability matched introduced levels of expectation. For the duration of each experiment, the lower-than groups' perceptions were lower than the actual automation reliability. However, the higher-than groups' perceptions were no different from actual automation reliability after Day 1 in either study. There were few differences between groups for automation use, which generally stayed the same or increased with experience using the system. Introductory statements describing artificially low automation reliability have a long-lasting impact on perceptions about automation performance. Statements including incorrect automation reliability do not appear to affect use of automation. Introductions should be designed according to desired outcomes for expectations, perceptions, and use of the automation. Low expectations have long-lasting effects. © 2015, Human Factors and Ergonomics Society.

  17. Evaluation of speech errors in Putonghua speakers with cleft palate: a critical review of methodology issues.

    PubMed

    Jiang, Chenghui; Whitehill, Tara L

    2014-04-01

    Speech errors associated with cleft palate are well established for English and several other Indo-European languages. Few articles describing the speech of Putonghua (standard Mandarin Chinese) speakers with cleft palate have been published in English language journals. Although methodological guidelines have been published for the perceptual speech evaluation of individuals with cleft palate, there has been no critical review of methodological issues in studies of Putonghua speakers with cleft palate. A literature search was conducted to identify relevant studies published over the past 30 years in Chinese language journals. Only studies incorporating perceptual analysis of speech were included. Thirty-seven articles which met inclusion criteria were analyzed and coded on a number of methodological variables. Reliability was established by having all variables recoded for all studies. This critical review identified many methodological issues. These design flaws make it difficult to draw reliable conclusions about characteristic speech errors in this group of speakers. Specific recommendations are made to improve the reliability and validity of future studies, as well to facilitate cross-center comparisons.

  18. Inter-rater reliability of select physical examination procedures in patients with neck pain.

    PubMed

    Hanney, William J; George, Steven Z; Kolber, Morey J; Young, Ian; Salamh, Paul A; Cleland, Joshua A

    2014-07-01

    This study evaluated the inter-rater reliability of select examination procedures in patients with neck pain (NP) conducted over a 24- to 48-h period. Twenty-two patients with mechanical NP participated in a standardized examination. One examiner performed standardized examination procedures and a second blinded examiner repeated the procedures 24-48 h later with no treatment administered between examinations. Inter-rater reliability was calculated with the Cohen Kappa and weighted Kappa for ordinal data while continuous level data were calculated using an intraclass correlation coefficient model 2,1 (ICC2,1). Coefficients for categorical variables ranged from poor to moderate agreement (-0.22 to 0.70 Kappa) and coefficients for continuous data ranged from slight to moderate (ICC2,1 0.28-0.74). The standard error of measurement for cervical range of motion ranged from 5.3° to 9.9° while the minimal detectable change ranged from 12.5° to 23.1°. This study is the first to report inter-rater reliability values for select components of the cervical examination in those patients with NP performed 24-48 h after the initial examination. There was considerably less reliability when compared to previous studies, thus clinicians should consider how the passage of time may influence variability in examination findings over a 24- to 48-h period.

  19. A flight test of laminar flow control leading-edge systems

    NASA Technical Reports Server (NTRS)

    Fischer, M. C.; Wright, A. S., Jr.; Wagner, R. D.

    1983-01-01

    NASA's program for development of a laminar flow technology base for application to commercial transports has made significant progress since its inception in 1976. Current efforts are focused on development of practical reliable systems for the leading-edge region where the most difficult problems in applying laminar flow exist. Practical solutions to these problems will remove many concerns about the ultimate practicality of laminar flow. To address these issues, two contractors performed studies, conducted development tests, and designed and fabricated fully functional leading-edge test articles for installation on the NASA JetStar aircraft. Systems evaluation and performance testing will be conducted to thoroughly evaluate all system capabilities and characteristics. A simulated airline service flight test program will be performed to obtain the operational sensitivity, maintenance, and reliability data needed to establish that practical solutions exist for the difficult leading-edge area of a future commercial transport employing laminar flow control.

  20. Reliability and concurrent and construct validity of the Strategies for Weight Management measure for adults.

    PubMed

    Kolodziejczyk, Julia K; Norman, Gregory J; Rock, Cheryl L; Arredondo, Elva M; Roesch, Scott C; Madanat, Hala; Patrick, Kevin

    2016-01-01

    This study evaluates the reliability and validity of the strategies for weight management (SWM) measure, a questionnaire that assesses weight management strategies for adults. The SWM includes 20 items that are categorized within the following subscales: (1) energy intake, (2) energy expenditure, (3) self-monitoring, and (4) self-regulation. Baseline and 6-month data were collected from 404 overweight/obese adults (mean age=22±3.8 years, 68% ethnic minority) enrolled in a randomized controlled trial aiming to reduce weight by improving diet and physical activity behaviours. Reliability and validity were assessed for each subscale separately. Cronbach alpha was conducted to assess reliability. Concurrent, construct I (sensitivity to the study treatment condition), and construct II (relationship to the outcomes) validity were assessed using linear regressions with the following outcome measures: weight, self-reported diet, and weekly energy expenditure. All subscales showed strong internal consistency. The strength of the validity evidence depended on subscale and validity type. The strongest validity evidence was concurrent validity of the energy intake and energy expenditure subscales; construct I validity of the energy intake and self-monitoring subscales; and construct II validity of the energy intake, energy expenditure, and self-regulation subscales. Results indicate that the SWM can be used to assess weight management strategies among an ethnically diverse sample of adults as each subscale showed evidence of reliability and select types of validity. As validity is an accumulation of evidence over multiple studies, this study provides initial reliability and validity evidence in one population segment. Copyright © 2015 Asia Oceania Association for the Study of Obesity. Published by Elsevier Ltd. All rights reserved.

  1. Adaptation and reliability of neighborhood environment walkability scale (NEWS) for Iran: A questionnaire for assessing environmental correlates of physical activity

    PubMed Central

    Hakimian, Pantea; Lak, Azadeh

    2016-01-01

    Background: In spite of the increased range of inactivity and obesity among Iranian adults, insufficient research has been done on environmental factors influencing physical activity. As a result adapting a subjective (self-report) measurement tool for assessment of physical environment in Iran is critical. Accordingly, in this study Neighborhood Environment Walkability Scale (NEWS) was adapted for Iran and also its reliability was evaluated. Methods: This study was conducted using a systematic adaptation method consisting of 3 steps: translate-back translation procedures, revision by a multidisciplinary panel of local experts and a cognitive study. Then NEWS-Iran was completed among adults aged 18 to 65 years (N=19) with an interval of 15 days. Intra-Class Coefficient (ICC) was used to evaluate the reliability of the adapted questionnaire. Results: NEWS-Iran is an adapted version of NEWS-A (abbreviated) and in the adaptation process five items were added from other versions of NEWS, two subscales were significantly modified for a shorter and more effective questionnaire, and five new items were added about climate factors and site-specific uses. NEWS-Iran showed almost perfect reliability (ICCs: more than 0.8) for all subscales, with items having moderate to almost perfect reliability scores (ICCs: 0.56-0.96). Conclusion: This study introduced NEWS-Iran, which is a reliable version of NEWS for measuring environmental perceptions related to physical activity behavior adapted for Iran. It is the first adapted version of NEWS which demonstrates a systematic adaptation process used by earlier studies. It can be used for other developing countries with similar environmental, social and cultural context. PMID:28210592

  2. Adaptation and reliability of neighborhood environment walkability scale (NEWS) for Iran: A questionnaire for assessing environmental correlates of physical activity.

    PubMed

    Hakimian, Pantea; Lak, Azadeh

    2016-01-01

    Background: In spite of the increased range of inactivity and obesity among Iranian adults, insufficient research has been done on environmental factors influencing physical activity. As a result adapting a subjective (self-report) measurement tool for assessment of physical environment in Iran is critical. Accordingly, in this study Neighborhood Environment Walkability Scale (NEWS) was adapted for Iran and also its reliability was evaluated. Methods: This study was conducted using a systematic adaptation method consisting of 3 steps: translate-back translation procedures, revision by a multidisciplinary panel of local experts and a cognitive study. Then NEWS-Iran was completed among adults aged 18 to 65 years (N=19) with an interval of 15 days. Intra-Class Coefficient (ICC) was used to evaluate the reliability of the adapted questionnaire. Results: NEWS-Iran is an adapted version of NEWS-A (abbreviated) and in the adaptation process five items were added from other versions of NEWS, two subscales were significantly modified for a shorter and more effective questionnaire, and five new items were added about climate factors and site-specific uses. NEWS-Iran showed almost perfect reliability (ICCs: more than 0.8) for all subscales, with items having moderate to almost perfect reliability scores (ICCs: 0.56-0.96). Conclusion: This study introduced NEWS-Iran, which is a reliable version of NEWS for measuring environmental perceptions related to physical activity behavior adapted for Iran. It is the first adapted version of NEWS which demonstrates a systematic adaptation process used by earlier studies. It can be used for other developing countries with similar environmental, social and cultural context.

  3. The role of graphene formed on silver nanowire transparent conductive electrode in ultra-violet light emitting diodes

    PubMed Central

    Seo, Tae Hoon; Lee, Seula; Min, Kyung Hyun; Chandramohan, S.; Park, Ah Hyun; Lee, Gun Hee; Park, Min; Suh, Eun-Kyung; Kim, Myung Jong

    2016-01-01

    This paper reports a highly reliable transparent conductive electrode (TCE) that integrates silver nanowires (AgNWs) and high-quality graphene as a protecting layer. Graphene with minimized defects and large graphene domains has been successfully obtained through a facile two-step growth approach. Ultraviolet light emitting diodes (UV-LEDs) were fabricated with AgNWs or hybrid electrodes where AgNWs were combined with two-step grown graphene (A-2GE) or conventional one-step grown graphene (A-1GE). The device performance and reliability of the UV-LEDs with three different electrodes were compared. The A-2GE offered high figure of merit owing to the excellent UV transmittance and reduced sheet resistance. As a consequence, the UV-LEDs made with A-2GE demonstrated reduced forward voltage, enhanced electroluminescence (EL) intensity, and alleviated efficiency droop. The effects of joule heating and UV light illumination on the electrode stability were also studied. The present findings prove superior performance of the A-2GE under high current injection and continuous operation of UV LED, compared to other electrodes. From our observation, the A-2GE would be a reliable TCE for high power UV-LEDs. PMID:27387274

  4. The role of graphene formed on silver nanowire transparent conductive electrode in ultra-violet light emitting diodes

    NASA Astrophysics Data System (ADS)

    Seo, Tae Hoon; Lee, Seula; Min, Kyung Hyun; Chandramohan, S.; Park, Ah Hyun; Lee, Gun Hee; Park, Min; Suh, Eun-Kyung; Kim, Myung Jong

    2016-07-01

    This paper reports a highly reliable transparent conductive electrode (TCE) that integrates silver nanowires (AgNWs) and high-quality graphene as a protecting layer. Graphene with minimized defects and large graphene domains has been successfully obtained through a facile two-step growth approach. Ultraviolet light emitting diodes (UV-LEDs) were fabricated with AgNWs or hybrid electrodes where AgNWs were combined with two-step grown graphene (A-2GE) or conventional one-step grown graphene (A-1GE). The device performance and reliability of the UV-LEDs with three different electrodes were compared. The A-2GE offered high figure of merit owing to the excellent UV transmittance and reduced sheet resistance. As a consequence, the UV-LEDs made with A-2GE demonstrated reduced forward voltage, enhanced electroluminescence (EL) intensity, and alleviated efficiency droop. The effects of joule heating and UV light illumination on the electrode stability were also studied. The present findings prove superior performance of the A-2GE under high current injection and continuous operation of UV LED, compared to other electrodes. From our observation, the A-2GE would be a reliable TCE for high power UV-LEDs.

  5. Validity and reliability of in-situ air conduction thresholds measured through hearing aids coupled to closed and open instant-fit tips.

    PubMed

    O'Brien, Anna; Keidser, Gitte; Yeend, Ingrid; Hartley, Lisa; Dillon, Harvey

    2010-12-01

    Audiometric measurements through a hearing aid ('in-situ') may facilitate provision of hearing services where these are limited. This study investigated the validity and reliability of in-situ air conduction hearing thresholds measured with closed and open domes relative to thresholds measured with insert earphones, and explored sources of variability in the measures. Twenty-four adults with sensorineural hearing impairment attended two sessions in which thresholds and real-ear-to-dial-difference (REDD) values were measured. Without correction, significantly higher low-frequency thresholds in dB HL were measured in-situ than with insert earphones. Differences were due predominantly to differences in ear canal SPL, as measured with the REDD, which were attributed to leaking low-frequency energy. Test-retest data yielded higher variability with the closed dome coupling due to inconsistent seals achieved with this tip. For all three conditions, inter-participant variability in the REDD values was greater than intra-participant variability. Overall, in-situ audiometry is as valid and reliable as conventional audiometry provided appropriate REDD corrections are made and ambient sound in the test environment is controlled.

  6. Health Service Quality Scale: Brazilian Portuguese translation, reliability and validity.

    PubMed

    Rocha, Luiz Roberto Martins; Veiga, Daniela Francescato; e Oliveira, Paulo Rocha; Song, Elaine Horibe; Ferreira, Lydia Masako

    2013-01-17

    The Health Service Quality Scale is a multidimensional hierarchical scale that is based on interdisciplinary approach. This instrument was specifically created for measuring health service quality based on marketing and health care concepts. The aim of this study was to translate and culturally adapt the Health Service Quality Scale into Brazilian Portuguese and to assess the validity and reliability of the Brazilian Portuguese version of the instrument. We conducted a cross-sectional, observational study, with public health system patients in a Brazilian university hospital. Validity was assessed using Pearson's correlation coefficient to measure the strength of the association between the Brazilian Portuguese version of the instrument and the SERVQUAL scale. Internal consistency was evaluated using Cronbach's alpha coefficient; the intraclass (ICC) and Pearson's correlation coefficients were used for test-retest reliability. One hundred and sixteen consecutive postoperative patients completed the questionnaire. Pearson's correlation coefficient for validity was 0.20. Cronbach's alpha for the first and second administrations of the final version of the instrument were 0.982 and 0.986, respectively. For test-retest reliability, Pearson's correlation coefficient was 0.89 and ICC was 0.90. The culturally adapted, Brazilian Portuguese version of the Health Service Quality Scale is a valid and reliable instrument to measure health service quality.

  7. A Study on the Reliability of Sasang Constitutional Body Trunk Measurement

    PubMed Central

    Jang, Eunsu; Kim, Jong Yeol; Lee, Haejung; Kim, Honggie; Baek, Younghwa; Lee, Siwoo

    2012-01-01

    Objective. Body trunk measurement for human plays an important diagnostic role not only in conventional medicine but also in Sasang constitutional medicine (SCM). The Sasang constitutional body trunk measurement (SCBTM) consists of the 5-widths and the 8-circumferences which are standard locations currently employed in the SCM society. This study suggests to what extent a comprehensive training can improve the reliability of the SCBTM. Methods. We recruited 10 male subjects and 5 male observers with no experience of anthropometric measurement. We conducted measurements twice before and after a comprehensive training. Relative technical error of measurement (%TEMs) was produced to assess intra and inter observer reliabilities. Results. Post-training intra-observer %TEMs of the SCBTM were 0.27% to 1.85% reduced from 0.27% to 6.26% in pre-training, respectively. Post-training inter-observer %TEMs of those were 0.56% to 1.66% reduced from 1.00% to 9.60% in pre-training, respectively. Post-training % total TEMs which represent the whole reliability were 0.68% to 2.18% reduced from maximum value of 10.18%. Conclusion. A comprehensive training makes the SCBTM more reliable, hence giving a sufficiently confident diagnostic tool. It is strongly recommended to give a comprehensive training in advance to take the SCBTM. PMID:21822442

  8. Validation in the cross-cultural adaptation of the Korean version of the Oswestry Disability Index.

    PubMed

    Jeon, Chang-Hoon; Kim, Dong-Jae; Kim, Se-Kang; Kim, Dong-Jun; Lee, Hwan-Mo; Park, Heui-Jeon

    2006-12-01

    Disability questionnaires are used for clinical assessment, outcome measurement, and research methodology. Any disability measurement must be adapted culturally for comparability of data, when the patients, who are measured, use different languages. This study aimed to conduct cross-cultural adaptation in translating the original (English) version of the Oswestry Disability Index (ODI) into Korean, and then to assess the reliability of the Korean versions of the Oswestry Disability Index (KODI). We used methodology to obtain semantic, idiomatic, experimental, and conceptual equivalences for the process of cross-cultural adaptation. The KODI were tested in 116 patients with chronic low back pain. The internal consistency and reliability for the KODI reached 0.9168 (Cronbach's alpha). The test-retest reliability was assessed with 32 patients (who were not included in the assessment of Cronbach's alpha) over a time interval of 4 days. Test-retest correlation reliability was 0.9332. The entire process and the results of this study were reported to the developer (Dr. Fairbank JC), who appraised the KODI. There is little evidence of differential item functioning in KODI. The results suggest that the KODI is internally consistent and reliable. Therefore, the KODI can be recommended as a low back pain assessment tool in Korea.

  9. Validation in the Cross-Cultural Adaptation of the Korean Version of the Oswestry Disability Index

    PubMed Central

    Kim, Dong-Jae; Kim, Se-Kang; Kim, Dong-Jun; Lee, Hwan-Mo; Park, Heui-Jeon

    2006-01-01

    Disability questionnaires are used for clinical assessment, outcome measurement, and research methodology. Any disability measurement must be adapted culturally for comparability of data, when the patients, who are measured, use different languages. This study aimed to conduct cross-cultural adaptation in translating the original (English) version of the Oswestry Disability Index (ODI) into Korean, and then to assess the reliability of the Korean versions of the Oswestry Disability Index (KODI). We used methodology to obtain semantic, idiomatic, experimental, and conceptual equivalences for the process of cross-cultural adaptation. The KODI were tested in 116 patients with chronic low back pain. The internal consistency and reliability for the KODI reached 0.9168 (Cronbach's alpha). The test-retest reliability was assessed with 32 patients (who were not included in the assessment of Cronbach's alpha) over a time interval of 4 days. Test-retest correlation reliability was 0.9332. The entire process and the results of this study were reported to the developer (Dr. Fairbank JC), who appraised the KODI. There is little evidence of differential item functioning in KODI. The results suggest that the KODI is internally consistent and reliable. Therefore, the KODI can be recommended as a low back pain assessment tool in Korea. PMID:17179693

  10. The birth satisfaction scale: Turkish adaptation, validation and reliability study

    PubMed Central

    Cetin, Fatma Cosar; Sezer, Ayse; Merih, Yeliz Dogan

    2015-01-01

    OBJECTIVE: The objective of this study is to investigate the validity and the reliability of Birth Satisfaction Scale (BSS) and to adapt it into the Turkish language. This scale is used for measuring maternal satisfaction with birth in order to evaluate women’s birth perceptions. METHODS: In this study there were 150 women who attended to inpatient postpartum clinic. The participants filled in an information form and the BSS questionnaire forms. The properties of the scale were tested by conducting reliability and validation analyses. RESULTS: BSS entails 30 Likert-type questions. It was developed by Hollins Martin and Fleming. Total scale scores ranged between 30–150 points. Higher scores from the scale mean increases in birth satisfaction. Three overarching themes were identified in Scale: service provision (home assessment, birth environment, support, relationships with health care professionals); personal attributes (ability to cope during labour, feeling in control, childbirth preparation, relationship with baby); and stress experienced during labour (distress, obstetric injuries, receiving sufficient medical care, obstetric intervention, pain, prolonged labour and baby’s health). Cronbach’s alfa coefficient was 0.62. CONCLUSION: According to the present study, BSS entails 30 Likert-type questions and evaluates women’s birth perceptions. The Turkish version of BSS has been proven to be a valid and a reliable scale. PMID:28058355

  11. Barwood CNG Cab Fleet Study: Final Results

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Whalen, P.; Kelly, K.; John, M.

    1999-05-03

    This report describes a fleet study conducted over a 12-month period to evaluate the operation of dedicated compress natural gas (CNG) Ford Crown Victoria sedans in a taxicab fleet. In the study, we assess the performance and reliability of the vehicles and the cost of operating the CNG vehicles compared to gasoline vehicles. The study results reveal that the CNG vehicles operated by this fleet offer both economic and environmental advantages. The total operating costs of the CNG vehicles were about 25% lower than those of the gasoline vehicles. The CNG vehicles performed as well as the gasoline vehicles, andmore » were just as reliable. Barwood representatives and drivers have come to consider the CNG vehicles an asset to their business and to the air quality of the local community.« less

  12. Reliability of new software in measuring cervical multifidus diameters and shoulder muscle strength in a synchronized way; an ultrasonographic study

    PubMed Central

    Rahnama, Leila; Rezasoltani, Asghar; Khalkhali-Zavieh, Minoo; Rahnama, Behnam; Noori-Kochi, Farhang

    2015-01-01

    OBJECTIVES: This study was conducted with the purpose of evaluating the inter-session reliability of new software to measure the diameters of the cervical multifidus muscle (CMM), both at rest and during isometric contractions of the shoulder abductors in subjects with neck pain and in healthy individuals. METHOD: In the present study, the reliability of measuring the diameters of the CMM with the Sonosynch software was evaluated by using 24 participants, including 12 subjects with chronic neck pain and 12 healthy individuals. The anterior-posterior diameter (APD) and the lateral diameter (LD) of the CMM were measured in a resting state and then repeated during isometric contraction of the shoulder abductors. Measurements were taken on separate occasions 3 to 7 days apart in order to determine inter-session reliability. Intraclass correlation coefficient (ICC), standard error of measurement (SEM), and smallest detectable difference (SDD) were used to evaluate the relative and absolute reliability, respectively. RESULTS: The Sonosynch software has shown to be highly reliable in measuring the diameters of the CMM both in healthy subjects and in those with neck pain. The ICCs 95% CI for APD ranged from 0.84 to 0.94 in subjects with neck pain and from 0.86 to 0.94 in healthy subjects. For LD, the ICC 95% CI ranged from 0.64 to 0.95 in subjects with neck pain and from 0.82 to 0.92 in healthy subjects. CONCLUSIONS: Ultrasonographic measurement of the diameters of the CMM using Sonosynch has proved to be reliable especially for APD in healthy subjects as well as subjects with neck pain. PMID:26443975

  13. Characterizing the Reproducibility and Reliability of Dietary Patterns among Yup’ik Alaska Native People

    PubMed Central

    Ryman, Tove K.; Boyer, Bert B.; Hopkins, Scarlett; Philip, Jacques; O’Brien, Diane; Thummel, Kenneth; Austin, Melissa A.

    2015-01-01

    Food frequency questionnaire (FFQ) data can be used to characterize dietary patterns for diet-disease association studies. Among a sample of Yup’ik people from Southwest Alaska, we evaluated three previously defined dietary patterns: “subsistence foods” and market-based “processed foods” and “fruits and vegetables”. We tested the reproducibility and reliability of the dietary patterns and tested associations of the patterns with dietary biomarkers and participant characteristics. We analyzed data from adult study participants who completed at least one FFQ with the Center for Alaska Native Health Research 9/2009–5/2013. To test reproducibility we conducted a confirmatory factor analysis (CFA) of a hypothesized model using 18 foods to measure the dietary patterns (n=272). To test the reliability of the dietary patterns, we used CFA to measure the composite reliability (n=272) and intraclass correlation coefficients for test-retest reliability (n=113). Finally, to test associations we used linear regression (n=637). All CFA factor loadings, except one, indicated acceptable correlations between foods and dietary patterns (r > 0.40) and model fit criteria were greater than 0.90. Composite and test-retest reliability of dietary patterns were respectively 0.56 and 0.34 for subsistence foods, 0.73 and 0.66 for processed foods, and 0.72 and 0.54 for fruits and vegetables. In the multi-predictor analysis, dietary patterns were significantly associated with dietary biomarkers, community location, age, sex, and self-reported lifestyle. This analysis confirmed the reproducibility and reliability of the dietary patterns in this study population. These dietary patterns can be used for future research and development of dietary interventions in this underserved population. PMID:25656871

  14. Metrics for Assessing the Reliability of a Telemedicine Remote Monitoring System

    PubMed Central

    Fox, Mark; Papadopoulos, Amy; Crump, Cindy

    2013-01-01

    Abstract Objective: The goal of this study was to assess using new metrics the reliability of a real-time health monitoring system in homes of older adults. Materials and Methods: The “MobileCare Monitor” system was installed into the homes of nine older adults >75 years of age for a 2-week period. The system consisted of a wireless wristwatch-based monitoring system containing sensors for location, temperature, and impacts and a “panic” button that was connected through a mesh network to third-party wireless devices (blood pressure cuff, pulse oximeter, weight scale, and a survey-administering device). To assess system reliability, daily phone calls instructed participants to conduct system tests and reminded them to fill out surveys and daily diaries. Phone reports and participant diary entries were checked against data received at a secure server. Results: Reliability metrics assessed overall system reliability, data concurrence, study effectiveness, and system usability. Except for the pulse oximeter, system reliability metrics varied between 73% and 92%. Data concurrence for proximal and distal readings exceeded 88%. System usability following the pulse oximeter firmware update varied between 82% and 97%. An estimate of watch-wearing adherence within the home was quite high, about 80%, although given the inability to assess watch-wearing when a participant left the house, adherence likely exceeded the 10 h/day requested time. In total, 3,436 of 3,906 potential measurements were obtained, indicating a study effectiveness of 88%. Conclusions: The system was quite effective in providing accurate remote health data. The different system reliability measures identify important error sources in remote monitoring systems. PMID:23611640

  15. Quantitative comparison of in situ soil CO2 flux measurement methods

    Treesearch

    Jennifer D. Knoepp; James M. Vose

    2002-01-01

    Development of reliable regional or global carbon budgets requires accurate measurement of soil CO2 flux. We conducted laboratory and field studies to determine the accuracy and comparability of methods commonly used to measure in situ soil CO2 fluxes. Methods compared included CO2...

  16. Psychometric Properties of Work-Related Behavior and Experience Patterns (AVEM) Scale

    ERIC Educational Resources Information Center

    Gencer, R. Timucin; Boyacioglu, Hayal; Kiremitci, Olcay; Dogan, Birol

    2010-01-01

    "Work-Related Behaviour and Experience Patterns" (AVEM) has been developed with the intention of determining the occupation related behaviour and lifestyle models of professionals. This study has been conducted to test the validity and reliability of MEDYAM, the abbreviated Turkish equivalent of AVEM. 373 teachers from 10 different…

  17. Measures of Searcher Performance: A Psychometric Evaluation.

    ERIC Educational Resources Information Center

    Wildemuth, Barbara M.; And Others

    1993-01-01

    Describes a study of medical students that was conducted to evaluate measures of performance on factual searches of INQUIRER, a full-text database in microbiology. Measures relating to recall, precision, search term overlap, and efficiency are discussed; reliability and construct validity are considered; and implications for future research are…

  18. Phonics Curriculum-Based Measurement: An Initial Study of Reliability and Validity

    ERIC Educational Resources Information Center

    Swanson, Chad C.

    2014-01-01

    Early literacy and reading skills are both important predictors of an individual's future success in school and employment settings (Moats, 1999). Moreover, poor reading performance in elementary school has been associated with future conduct problems and juvenile delinquency by age fifteen (Williams, 1994). Research supports the notion that…

  19. Voice Recognition: A New Assessment Tool?

    ERIC Educational Resources Information Center

    Jones, Darla

    2005-01-01

    This article presents the results of a study conducted in Anchorage, Alaska, that evaluated the accuracy and efficiency of using voice recognition (VR) technology to collect oral reading fluency data for classroom-based assessments. The primary research question was as follows: Is voice recognition technology a valid and reliable alternative to…

  20. Development and Determination of Reliability and Validity of Professional Learning Community Collaborative Team Survey (CTS)

    ERIC Educational Resources Information Center

    Colvin, Joshua A.

    2013-01-01

    The study of transformative learning within collaborative teams was conducted to gain new applicable knowledge used to influence overall school improvement and implementation of professional learning communities. To obtain this new knowledge, the Professional Learning Community Collaborative Team Survey (CTS) was developed and psychometrically…

  1. Initial Reliability and Validity of the Perceived Social Competence Scale

    ERIC Educational Resources Information Center

    Anderson-Butcher, Dawn; Iachini, Aidyn L.; Amorose, Anthony J.

    2008-01-01

    Objective: This study describes the development and validation of a perceived social competence scale that social workers can easily use to assess children's and youth's social competence. Method: Exploratory and confirmatory factor analyses were conducted on a calibration and a cross-validation sample of youth. Predictive validity was also…

  2. Thriving in Community

    ERIC Educational Resources Information Center

    Schreiner, Laurie A.

    2010-01-01

    In the previous two issues of "About Campus," the author has described the national study of college-student thriving that she has conducted with her doctoral students at Azusa Pacific University over the past several years. Their validated and reliable 35-item Thriving Quotient has been administered to over 15,000 college students…

  3. Analysis of variograms with various sample sizes from a multispectral image

    USDA-ARS?s Scientific Manuscript database

    Variogram plays a crucial role in remote sensing application and geostatistics. It is very important to estimate variogram reliably from sufficient data. In this study, the analysis of variograms with various sample sizes of remotely sensed data was conducted. A 100x100-pixel subset was chosen from ...

  4. Magnetoacoustic Tomography with Magnetic Induction for Electrical Conductivity based Tissue imaging

    NASA Astrophysics Data System (ADS)

    Mariappan, Leo

    Electrical conductivity imaging of biological tissue has attracted considerable interest in recent years owing to research indicating that electrical properties, especially electrical conductivity and permittivity, are indicators of underlying physiological and pathological conditions in biological tissue. Also, the knowledge of electrical conductivity of biological tissue is of interest to researchers conducting electromagnetic source imaging and in design of devices that apply electromagnetic energy to the body such as MRI. So, the need for a non-invasive, high resolution impedance imaging method is highly desired. To address this need we have studied the magnetoacoustic tomography with magnetic induction (MAT-MI) method. In MAT-MI, the object is placed in a static and a dynamic magnetic field giving rise to ultrasound waves. The dynamic field induces eddy currents in the object, and the static field leads to generation of acoustic vibrations from Lorentz force on the induced currents. The acoustic vibrations are at the same frequency as the dynamic magnetic field, which is chosen to match the ultrasound frequency range. These ultrasound signals can be measured by ultrasound probes and are used to reconstruct MAT-MI acoustic source images using possible ultrasound imaging approaches .The reconstructed high spatial resolution image is indicative of the object's electrical conductivity contrast. We have investigated ultrasound imaging methods to reliably reconstruct the MAT-MI image under the practical conditions of limited bandwidth and transducer geometry. The corresponding imaging algorithm, computer simulation and experiments are developed to test the feasibility of these different methods. Also, in experiments, we have developed a system with the strong static field of an MRI magnet and a strong pulsed magnetic field to evaluate MAT-MI in biological tissue imaging. It can be seen from these simulations and experiments that conductivity boundary images with millimeter resolution can be reliably reconstructed with MAT-MI. Further, to estimate the conductivity distribution throughout the object, we reconstruct a vector source image corresponding to the induced eddy currents. As the current source is uniformly present throughout the object, we are able to reliably estimate the internal conductivity distribution for a more complete imaging. From the computer simulations and experiments it can be seen that MAT-MI method has the potential to be a clinically applicable, high resolution, non-invasive method for electrical conductivity imaging.

  5. Reliability and Maintainability Analysis: A Conceptual Design Model

    DTIC Science & Technology

    1972-03-01

    Elements For a System I. Research ane Development A. Preliminary design and engineering B. Fabrication of test equipment C. Test operations D...reliability racquiro:wents, little, if any, modu larzation and auto- matic test features would be incorporated in the subsystem design, limited reliability...niaintaina~ility testing and monitoring would be conducted turing dev!qopmcnt, and little Quality Control effort, in the rell ability/’uaintainalility

  6. Study of the Results in the Acquisition of Core Competencies in Schools That Integrate Primary Education and Music

    ERIC Educational Resources Information Center

    Andreu Duran, Maria; Godall Castell, Pere; Amador Guillem, Miquel; Castro Morera, Maria

    2017-01-01

    The goal of this research was to carry out an exploratory study on how music education integrated into primary schooling (children from 6 to 12 years old) can help in acquiring the core competencies characteristic of this stage. The study was conducted by developing a validated instrument, pilot-tested for reliability, to assess the eight core…

  7. Quality and rigor of the concept mapping methodology: a pooled study analysis.

    PubMed

    Rosas, Scott R; Kane, Mary

    2012-05-01

    The use of concept mapping in research and evaluation has expanded dramatically over the past 20 years. Researchers in academic, organizational, and community-based settings have applied concept mapping successfully without the benefit of systematic analyses across studies to identify the features of a methodologically sound study. Quantitative characteristics and estimates of quality and rigor that may guide for future studies are lacking. To address this gap, we conducted a pooled analysis of 69 concept mapping studies to describe characteristics across study phases, generate specific indicators of validity and reliability, and examine the relationship between select study characteristics and quality indicators. Individual study characteristics and estimates were pooled and quantitatively summarized, describing the distribution, variation and parameters for each. In addition, variation in the concept mapping data collection in relation to characteristics and estimates was examined. Overall, results suggest concept mapping yields strong internal representational validity and very strong sorting and rating reliability estimates. Validity and reliability were consistently high despite variation in participation and task completion percentages across data collection modes. The implications of these findings as a practical reference to assess the quality and rigor for future concept mapping studies are discussed. Copyright © 2011 Elsevier Ltd. All rights reserved.

  8. Development and Psychometric Properties of Social Exclusion Questionnaire for Iranian Divorced Women

    PubMed Central

    ZAREI, Fatemeh; SOLHI, Mahnaz; MERGHATI-KHOEI, Effat; TAGHDISI, Mohammad Hossein; SHOJAEIZADEH, Davoud; TAKET, Ann Rosemary; MASOOMI, Razieh; NEDJAT, Saharnaz

    2017-01-01

    Background: Divorce, especially in women, could be assessed from socio-cultural perspective as well as psychological viewpoint. This assessment requires cultural adopted as well as valid and reliable questionnaire. This study aimed to develop and assess the psychometric properties of a questionnaire in order to address social consequences in Iranian divorced women. Methods: This was an exploratory mixed method study conducted during 2012 to 2014. According to the grounded theory approach in the first phase, social exclusion was extracted as a core of understanding process in participants. Based on, 47 preliminary generated items reliability and validity were assessed. In the second phase, the divorced women were recruited from a safe community center in Tehran through convenience sampling. Results: Exploratory factor analysis conducted on the questionnaires of 150 divorced women with mean age 41.76±8.49 yr, in that, indicated five dimensions, discriminative marital status, economic dependence on marital status, exclusionary marital status, and traumatic marital status health risks and, frightening marital status that jointly accounted for the 64% of the variance observed. An expert panel approved the face and content validity of the developed tool. The Cronbach’s alpha coefficient and the Intra-class Correlation Coefficient were found to be 0.70 and 0.85, respectively. Conclusion: The present study provided a valid and reliable measure as Social Exclusion Questionnaire in Iranian divorced women (SEQ-IDW) to address social post-divorce consequences, which might help to improve women’s social health. PMID:28560195

  9. Development and Psychometric Properties of Social Exclusion Questionnaire for Iranian Divorced Women.

    PubMed

    Zarei, Fatemeh; Solhi, Mahnaz; Merghati-Khoei, Effat; Taghdisi, Mohammad Hossein; Shojaeizadeh, Davoud; Taket, Ann Rosemary; Masoomi, Razieh; Nedjat, Saharnaz

    2017-05-01

    Divorce, especially in women, could be assessed from socio-cultural perspective as well as psychological viewpoint. This assessment requires cultural adopted as well as valid and reliable questionnaire. This study aimed to develop and assess the psychometric properties of a questionnaire in order to address social consequences in Iranian divorced women. This was an exploratory mixed method study conducted during 2012 to 2014. According to the grounded theory approach in the first phase, social exclusion was extracted as a core of understanding process in participants. Based on, 47 preliminary generated items reliability and validity were assessed. In the second phase, the divorced women were recruited from a safe community center in Tehran through convenience sampling. Exploratory factor analysis conducted on the questionnaires of 150 divorced women with mean age 41.76±8.49 yr, in that, indicated five dimensions, discriminative marital status, economic dependence on marital status, exclusionary marital status, and traumatic marital status health risks and, frightening marital status that jointly accounted for the 64% of the variance observed. An expert panel approved the face and content validity of the developed tool. The Cronbach's alpha coefficient and the Intra-class Correlation Coefficient were found to be 0.70 and 0.85, respectively. The present study provided a valid and reliable measure as Social Exclusion Questionnaire in Iranian divorced women (SEQ-IDW) to address social post-divorce consequences, which might help to improve women's social health.

  10. Design of Composite Structures for Reliability and Damage Tolerance

    NASA Technical Reports Server (NTRS)

    Rais-Rohani, Masoud

    1999-01-01

    A summary of research conducted during the first year is presented. The research objectives were sought by conducting two tasks: (1) investigation of probabilistic design techniques for reliability-based design of composite sandwich panels, and (2) examination of strain energy density failure criterion in conjunction with response surface methodology for global-local design of damage tolerant helicopter fuselage structures. This report primarily discusses the efforts surrounding the first task and provides a discussion of some preliminary work involving the second task.

  11. Compilation, design tests: Energetic particles Satellite S-3 including design tests for S-3A, S-3B and S-3C

    NASA Technical Reports Server (NTRS)

    Ledoux, F. N.

    1973-01-01

    A compilation of engineering design tests which were conducted in support of the Energetic Particle Satellite S-3, S-3A, and S-3b programs. The purpose for conducting the tests was to determine the adequacy and reliability of the Energetic Particles Series of satellites designs. The various tests consisted of: (1) moments of inertia, (2) functional reliability, (3) component and structural integrity, (4) initiators and explosives tests, and (5) acceptance tests.

  12. Measurement of patient safety: a systematic review of the reliability and validity of adverse event detection with record review

    PubMed Central

    Hanskamp-Sebregts, Mirelle; Zegers, Marieke; Vincent, Charles; van Gurp, Petra J; de Vet, Henrica C W; Wollersheim, Hub

    2016-01-01

    Objectives Record review is the most used method to quantify patient safety. We systematically reviewed the reliability and validity of adverse event detection with record review. Design A systematic review of the literature. Methods We searched PubMed, EMBASE, CINAHL, PsycINFO and the Cochrane Library and from their inception through February 2015. We included all studies that aimed to describe the reliability and/or validity of record review. Two reviewers conducted data extraction. We pooled κ values (κ) and analysed the differences in subgroups according to number of reviewers, reviewer experience and training level, adjusted for the prevalence of adverse events. Results In 25 studies, the psychometric data of the Global Trigger Tool (GTT) and the Harvard Medical Practice Study (HMPS) were reported and 24 studies were included for statistical pooling. The inter-rater reliability of the GTT and HMPS showed a pooled κ of 0.65 and 0.55, respectively. The inter-rater agreement was statistically significantly higher when the group of reviewers within a study consisted of a maximum five reviewers. We found no studies reporting on the validity of the GTT and HMPS. Conclusions The reliability of record review is moderate to substantial and improved when a small group of reviewers carried out record review. The validity of the record review method has never been evaluated, while clinical data registries, autopsy or direct observations of patient care are potential reference methods that can be used to test concurrent validity. PMID:27550650

  13. Reliability and determinants of anogenital distance and penis dimensions in male newborns from Chiapas, México

    PubMed Central

    Romano-Riquer, S. Patricia; Hernández-Ávila, Mauricio; Gladen, Beth C.; Cupul-Uicab, Lea A.; Longnecker, Matthew P.

    2013-01-01

    Summary Development of the perineum as well as the external genitalia is determined by dihydrotestosterone, resulting in a greater anogenital distance (AGD) in males than females. In animal experiments with hormonally active agents, anogenital distance is used as a bioassay of fetal androgen action. Use of anogenital distance in human studies has been rare. Because anogenital distance has been an easy-to-measure, sensitive outcome in animal studies, we developed an anthropometric protocol for measurement of anogenital distance in human males. In this paper we describe the method for measurement of three anogenital distances, their reliability, and an assessment of predictors for each in the context of an epidemiological study. We compare the reliabilities and predictors to those for stretched penis length and penis width. A cross-sectional study of 781 newly-delivered male infants was conducted in 2002–2003 in Chiapas, México. Replicate measures were obtained on nearly all subjects. The reliability of the measures of anogenital distance (0.82–0.91) were higher than for stretched penis length (0.78) and width (0.75). Birthweight and gestational length were more strongly related to anogenital distance than to penis length. Anogenital distance was not related to penis length (r = 0.03). Our large study clearly shows that AGD can be measured well in newborn males, and that the measurements were more reliable than those of penis length. Whether AGD measures in humans relate to clinically important outcomes, however, remains to be determined, as does its utility as a measure of androgen action in epidemiological studies. PMID:17439530

  14. Magnetically operated limit switch has improved reliability, minimizes arcing

    NASA Technical Reports Server (NTRS)

    Steiner, R.

    1966-01-01

    Limit switch for reliable, low-travel, snap action with negligible arcing uses an electrically nonconductive permanent magnet consisting of a ferrimagnetic ceramic and ferromagnetic pole shoes which form a magnetic and electrically conductive circuit with a ferrous-metal armature.

  15. Electric propulsion reliability: Statistical analysis of on-orbit anomalies and comparative analysis of electric versus chemical propulsion failure rates

    NASA Astrophysics Data System (ADS)

    Saleh, Joseph Homer; Geng, Fan; Ku, Michelle; Walker, Mitchell L. R.

    2017-10-01

    With a few hundred spacecraft launched to date with electric propulsion (EP), it is possible to conduct an epidemiological study of EP's on orbit reliability. The first objective of the present work was to undertake such a study and analyze EP's track record of on orbit anomalies and failures by different covariates. The second objective was to provide a comparative analysis of EP's failure rates with those of chemical propulsion. Satellite operators, manufacturers, and insurers will make reliability- and risk-informed decisions regarding the adoption and promotion of EP on board spacecraft. This work provides evidence-based support for such decisions. After a thorough data collection, 162 EP-equipped satellites launched between January 1997 and December 2015 were included in our dataset for analysis. Several statistical analyses were conducted, at the aggregate level and then with the data stratified by severity of the anomaly, by orbit type, and by EP technology. Mean Time To Anomaly (MTTA) and the distribution of the time to (minor/major) anomaly were investigated, as well as anomaly rates. The important findings in this work include the following: (1) Post-2005, EP's reliability has outperformed that of chemical propulsion; (2) Hall thrusters have robustly outperformed chemical propulsion, and they maintain a small but shrinking reliability advantage over gridded ion engines. Other results were also provided, for example the differentials in MTTA of minor and major anomalies for gridded ion engines and Hall thrusters. It was shown that: (3) Hall thrusters exhibit minor anomalies very early on orbit, which might be indicative of infant anomalies, and thus would benefit from better ground testing and acceptance procedures; (4) Strong evidence exists that EP anomalies (onset and likelihood) and orbit type are dependent, a dependence likely mediated by either the space environment or differences in thrusters duty cycles; (5) Gridded ion thrusters exhibit both infant and wear-out failures, and thus would benefit from a reliability growth program that addresses both these types of problems.

  16. Turkish Version of the Student Nurse Stress Index: Validity and Reliability.

    PubMed

    Sarikoc, Gamze; Bayram Demiralp, Meral; Oksuz, Emine; Pazar, Berrin

    2017-06-01

    This study aimed to adapt the Student Nurse Stress Index (SNSI) for the Turkish nursing students and investigate its psychometric properties. Research was conducted with 152 volunteer female students who attended a university college in Ankara, Turkey. Test-retest reliability was investigated for the scale internal consistency (Cronbach α) and stability. Also, content validity and construct validity of the SNSI were assessed. In order to determine the construct validity of SNSI, Uygulamalı Çok Değişkenli İstatistiksel Yöntemler and confirmatory factor analysis was conducted. The Turkish version of SNSI with 15 items comprised four factors (academic load, clinical concerns, personal problems, interface worries). The content validity index (CVI) score was .97. Factor loadings of Turkish version of SNSI varied between .532 and .868. The "personal problems" subscale explained 19.01% of the variance; "clinical concerns" explained 18.51%; "interface worries" explained 15.32%; "academic load" explained 14.14%. The total variance explained was 66.99%. CFA results (χ 2 /SD, GFI, CFI, TLI, IFI, RMSEA and SRMR) were acceptable and in good agreement. The internal consistency coefficient of the SNSI was .86. Results showed that the SNSI had a satisfactory level of reliability and validity in nursing students in Turkey. Multicenter studies including nursing students from different nursing schools are recommended for the SNSI to be generalized. Copyright © 2017. Published by Elsevier B.V.

  17. Conducting transcultural research: critical thinking in Thailand.

    PubMed

    Jenkins, Sheryl D

    2011-01-01

    Little has been written to help researchers prepare for the unique challenges of conducting transcultural research. The purpose of this article is to discuss issues that arose during the planning and execution of a transcultural study designed to compare critical thinking in Thailand and the United States. The challenges of identifying a research site, selecting participants, incorporating Thai research into the literature review, traveling and living in a foreign culture, overcoming cultural barriers to research, and strengthening internal validity and reliability are addressed.

  18. Validation of EORTC IN-PATSAT32 for Chinese cancer patients.

    PubMed

    Zhang, Lei; Dai, Zhenbo; Cheng, Siying; Xie, Shumin; Woo, Stephanie Mu-Lian; Luo, Zhiqin; Wu, Jinglian; Gao, Tianwen; Liu, Jiahao; Zhang, Kai; Zhang, Jing; Jia, Xinyu; Miller, Adam R; Wang, Changli

    2015-09-01

    The aim of this study is to test the psychometric properties and acceptability of the European Organization for Research and Treatment of Cancer (EORTC) inpatient satisfaction with care questionnaire 32 (IN-PATSAT32) for evaluating Chinese cancer patients and to analyze the influence of age, educational level, diagnostic time, and tumor stage on patient satisfaction. Three hundred two cancer inpatients in Tianjin Cancer Institution and Hospital from June 2013 to December 2013 were recruited for this study. All participants self-administered the EORTC IN-PATSAT32 and EORTC quality of life questionnaire-core 30 (QLQ-C30). Psychometric evaluation of the validity, reliability, acceptability, as well as the influence of age, educational level, diagnostic time, and tumor stage on patient satisfaction, was conducted. A favorable internal consistency reliability was confirmed, as the Cronbach's α coefficients were >0.80 for all scales in the EORTC IN-PATSAT32, ranging from 0.849 to 0.944. Multi-trait scaling analysis showed that all item-scale correlation coefficients met the standard of convergent validity, and 79.3 % met the standard of discriminant validity. Weak correlations were found between the scales and single items of the EORTC IN-PATSAT32 and EORTC QLQ-C30, proving the validity of EORTC IN-PATSAT32. None of the EORTC IN-PATSAT32 scales were able to discriminate between patients across age categories, while significant influences of educational level on doctors' and nurses' conduct, as well as influences of diagnostic time and tumor stage on nurses' conduct, and information provision scales were discovered. The questionnaire was easily understood with a satisfactory acceptability. The EORTC IN-PATSAT32 appears to be a reliable, valid, and acceptable instrument to use on cancer patients and is appropriate for measuring the patient satisfaction of Chinese patients.

  19. Assessing environmental features related to mental health: a reliability study of visual streetscape images.

    PubMed

    Wu, Yu-Tzu; Nash, Paul; Barnes, Linda E; Minett, Thais; Matthews, Fiona E; Jones, Andy; Brayne, Carol

    2014-10-22

    An association between depressive symptoms and features of built environment has been reported in the literature. A remaining research challenge is the development of methods to efficiently capture pertinent environmental features in relevant study settings. Visual streetscape images have been used to replace traditional physical audits and directly observe the built environment of communities. The aim of this work is to examine the inter-method reliability of the two audit methods for assessing community environments with a specific focus on physical features related to mental health. Forty-eight postcodes in urban and rural areas of Cambridgeshire, England were randomly selected from an alphabetical list of streets hosted on a UK property website. The assessment was conducted in July and August 2012 by both physical and visual image audits based on the items in Residential Environment Assessment Tool (REAT), an observational instrument targeting the micro-scale environmental features related to mental health in UK postcodes. The assessor used the images of Google Street View and virtually "walked through" the streets to conduct the property and street level assessments. Gwet's AC1 coefficients and Bland-Altman plots were used to compare the concordance of two audits. The results of conducting the REAT by visual image audits generally correspond to direct observations. More variations were found in property level items regarding physical incivilities, with broad limits of agreement which importantly lead to most of the variation in the overall REAT score. Postcodes in urban areas had lower consistency between the two methods than rural areas. Google Street View has the potential to assess environmental features related to mental health with fair reliability and provide a less resource intense method of assessing community environments than physical audits.

  20. The validity and reliability of the four square step test in different adult populations: a systematic review.

    PubMed

    Moore, Martha; Barker, Karen

    2017-09-11

    The four square step test (FSST) was first validated in healthy older adults to provide a measure of dynamic standing balance and mobility. The FSST has since been used in a variety of patient populations. The purpose of this systematic review is to determine the validity and reliability of the FSST in these different adult patient populations. The literature search was conducted to highlight all the studies that measured validity and reliability of the FSST. Six electronic databases were searched including AMED, CINAHL, MEDLINE, PEDro, Web of Science and Google Scholar. Grey literature was also searched for any documents relevant to the review. Two independent reviewers carried out study selection and quality assessment. The methodological quality was assessed using the QUADAS-2 tool, which is a validated tool for the quality assessment of diagnostic accuracy studies, and the COSMIN four-point checklist, which contains standards for evaluating reliability studies on the measurement properties of health instruments. Fifteen studies were reviewed studying community-dwelling older adults, Parkinson's disease, Huntington's disease, multiple sclerosis, vestibular disorders, post stroke, post unilateral transtibial amputation, knee pain and hip osteoarthritis. Three of the studies were of moderate methodological quality scoring low in risk of bias and applicability for all domains in the QUADAS-2 tool. Three studies scored "fair" on the COSMIN four-point checklist for the reliability components. The concurrent validity of the FSST was measured in nine of the studies with moderate to strong correlations being found. Excellent Intraclass Correlation Coefficients were found between physiotherapists carrying out the tests (ICC = .99) with good to excellent test-retest reliability shown in nine of the studies (ICC = .73-.98). The FSST may be an effective and valid tool for measuring dynamic balance and a participants' falls risk. It has been shown to have strong correlations with other measures of balance and mobility with good reliability shown in a number of populations. However, the quality of the papers reviewed was variable with key factors, such as sample size and test set up, needing to be addressed before the tool can be confidently used in these specified populations.

  1. Automation in visual inspection tasks: X-ray luggage screening supported by a system of direct, indirect or adaptable cueing with low and high system reliability.

    PubMed

    Chavaillaz, Alain; Schwaninger, Adrian; Michel, Stefan; Sauer, Juergen

    2018-05-25

    The present study evaluated three automation modes for improving performance in an X-ray luggage screening task. 140 participants were asked to detect the presence of prohibited items in X-ray images of cabin luggage. Twenty participants conducted this task without automatic support (control group), whereas the others worked with either indirect cues (system indicated the target presence without specifying its location), or direct cues (system pointed out the exact target location) or adaptable automation (participants could freely choose between no cue, direct and indirect cues). Furthermore, automatic support reliability was manipulated (low vs. high). The results showed a clear advantage for direct cues regarding detection performance and response time. No benefits were observed for adaptable automation. Finally, high automation reliability led to better performance and higher operator trust. The findings overall confirmed that automatic support systems for luggage screening should be designed such that they provide direct, highly reliable cues.

  2. Reliability, Validity, and Factor Structure of the Current Assessment Practice Evaluation-Revised (CAPER) in a National Sample.

    PubMed

    Lyon, Aaron R; Pullmann, Michael D; Dorsey, Shannon; Martin, Prerna; Grigore, Alexandra A; Becker, Emily M; Jensen-Doss, Amanda

    2018-05-11

    Measurement-based care (MBC) is an increasingly popular, evidence-based practice, but there are no tools with established psychometrics to evaluate clinician use of MBC practices in mental health service delivery. The current study evaluated the reliability, validity, and factor structure of scores generated from a brief, standardized tool to measure MBC practices, the Current Assessment Practice Evaluation-Revised (CAPER). Survey data from a national sample of 479 mental health clinicians were used to conduct exploratory and confirmatory factor analyses, as well as reliability and validity analyses (e.g., relationships between CAPER subscales and clinician MBC attitudes). Analyses revealed competing two- and three-factor models. Regardless of the model used, scores from CAPER subscales demonstrated good reliability and convergent and divergent validity with MBC attitudes in the expected directions. The CAPER appears to be a psychometrically sound tool for assessing clinician MBC practices. Future directions for development and application of the tool are discussed.

  3. Development of a self-report questionnaire designed for population-based surveillance of gingivitis in adolescents: assessment of content validity and reliability.

    PubMed

    Quiroz, Viviana; Reinero, Daniela; Hernández, Patricia; Contreras, Johanna; Vernal, Rolando; Carvajal, Paola

    2017-01-01

    This study aimed to develop and assess the content validity and reliability of a cognitively adapted self-report questionnaire designed for surveillance of gingivitis in adolescents. Ten predetermined self-report questions evaluating early signs and symptoms of gingivitis were preliminary assessed by a panel of clinical experts. Eight questions were selected and cognitively tested in 20 adolescents aged 12 to 18 years from Santiago de Chile. The questionnaire was then conducted and answered by 178 Chilean adolescents. Internal consistency was measured using the Cronbach's alpha and temporal stability was calculated using the Kappa-index. A reliable final self-report questionnaire consisting of 5 questions was obtained, with a total Cronbach's alpha of 0.73 and a Kappa-index ranging from 0.41 to 0.77 between the different questions. The proposed questionnaire is reliable, with an acceptable internal consistency and a temporal stability from moderate to substantial, and it is promising for estimating the prevalence of gingivitis in adolescents.

  4. Examining the Measurement Precision and Invariance of the Revised Get Ready to Read!

    PubMed Central

    Farrington, Amber L.; Lonigan, Christopher J.

    2016-01-01

    Children's emergent literacy skills are highly predictive of later reading abilities. To determine which children have weaker emergent literacy skills and are in need of intervention, it is necessary to assess emergent literacy skills accurately and reliably. In this study, 1,351 children were administered the Revised Get Ready to Read! (GRTR-R), and an item response theory analysis was used to evaluate the item-level reliability of the measure. Differential item functioning (DIF) analyses were conducted to examine whether items function similarly between subpopulations of children. The GRTR-R had acceptable reliability for children whose ability level was just below the mean. DIF for a small number of items was present for only two comparisons—children who were older versus younger and children who were White versus African American. These results demonstrate that the GRTR-R has acceptable reliability and limited DIF, enabling the screener to identify those at risk for developing reading problems. PMID:23851136

  5. A hedonic analysis of big game hunting club dues in Georgia, USA

    Treesearch

    James C. Mingie; Neelam C. Poudyal; J. M.  Bowker; Michael T.  Mengak; Jacek P.  Siry

    2017-01-01

    Hunting lease revenue can be a reliable supplemental income for forest landowners. Although studies have examined factors influencing per acre lease rates, little is known about how various characteristics are capitalized in hunting club dues. The objective of this study was to conduct a hedonic analysis of big game hunting club dues in Georgia, USA using a variety of...

  6. A Multi-Stage Longitudinal Comparative Design Stage II Evaluation of the Changing Lives Program: The Life Course Interview (RDA-LCI)

    ERIC Educational Resources Information Center

    Arango, Lisa Lewis; Kurtines, William M.; Montgomery, Marilyn J.; Ritchie, Rachel

    2008-01-01

    The study reported in this article, a Multi-Stage Longitudinal Comparative Design Stage II evaluation conducted as a planned preliminary efficacy evaluation (psychometric evaluation of measures, short-term controlled outcome studies, etc.) of the Changing Lives Program (CLP), provided evidence for the reliability and validity of the qualitative…

  7. A Study on Developing Learning Strategies in Violin Education

    ERIC Educational Resources Information Center

    Afacan, Senol; Cilden, Seyda

    2018-01-01

    This study was conducted for the purpose of developing a valid and reliable learning strategies scale for students receiving violin education in Departments of Music at Fine Arts High Schools. The scale was applied to 391 violin students receiving education in the 11th and 12th grades in Departments of Music at Fine Arts High Schools in the…

  8. Pilot Study of a Parent Guided Website Access Package for Early Intervention Decision-Making for Autism Spectrum Disorder

    ERIC Educational Resources Information Center

    Carlon, Sarah; Carter, Mark; Stephenson, Jennifer

    2017-01-01

    A pilot study of the effectiveness of guided access to websites that provide information on intervention options for children with autism spectrum disorder (ASD) was conducted with 12 parents of preschool aged children with ASD. Guided access to reliable websites that included information about the effcacy of interventions for ASD (Raising…

  9. Strategic Word Attack: Acquired Contextual Strategies in Young Readers.

    ERIC Educational Resources Information Center

    Matz, Karl A.

    A study demonstrated that young children who have difficulty with phonics can be taught to read through other methods, that phonics is only one of the many useful strategies that a child can employ, and that many contextual strategies are easier to learn and more reliable than phonics. A case study was conducted during an intervention with a young…

  10. Attachment narratives in refugee children: interrater reliability and qualitative analysis in pilot findings from a two-site study.

    PubMed

    De Haene, Lucia; Dalgaard, Nina Thorup; Montgomery, Edith; Grietens, Hans; Verschueren, Karine

    2013-06-01

    Although forced migration research on refugee family functioning clearly points to the potential breakdown of parental availability and responsiveness in the context of cumulative migration stressors, studies exploring attachment security in refugee children are surprisingly lacking so far. The authors report their findings from a 2-site, small-scale administration of an attachment measure, adapted for use with refugee children aged between 4 and 9 years from a reliable and validated doll-play procedure. We evaluated interrater reliability and conducted a qualitative analysis of refugee children's narrative response to identify migration-specific representational markers of attachment quality. The level of agreement among 3 independent coders ranged between .54 to 1.00 for both study samples, providing initial psychometric evidence of the measure's value in assessing child attachment security in this population. The exploratory analysis of migration-related narrative markers pointed to specific parameters to be used in parent-child observational assessments in future validation of the attachment measure, such as parental withdrawal or trauma-communication within the parent-child dyad. Copyright © 2013 International Society for Traumatic Stress Studies.

  11. Urban traffic-related determinants of health questionnaire (UTDHQ): an instrument developed for health impact assessments.

    PubMed

    Nadrian, Haidar; Nedjat, Saharnaz; Taghdisi, Mohammad Hossein; Shojaeizadeh, Davoud

    2014-01-01

    Traffic and transport is a substantial part of a range of economic, social and environmental factors distinguished to have impact on human health. This paper is a report on a preliminary section of a Health Impact Assessment (HIA) on urban traffic and transport initiatives, being conducted in Sanandaj, Iran. In this preliminary study, the psychometric properties of Urban Traffic related Determinants of Health Questionnaire (UTDHQ) were investigated. Multistage cluster sampling was employed to recruit 476 key informants in Sanandaj from April to June 2013 to participate in the study. The development of UTDHQ began with a comprehensive review of the literature. Then face, content and construct validity as well as reliability were determined. Exploratory Factor Analysis showed optimal reduced solution including 40 items and 8 factors. Three of the factors identified were Physical Environment, Social Environment, Public Services Delivery and Accessibility. UTDHQ demonstrated an appropriate validity, reliability, functionality and simplicity. Despite the need for further studies on UTDHQ, this study showed that it can be a practical and useful tool for conducting HIAs in order to inform decision makers and stakeholders about the health influences of their decisions and measures.

  12. Validation and reliability of the Turkish Utian Quality-of-Life Scale in postmenopausal women.

    PubMed

    Abay, Halime; Kaplan, Sena

    2016-04-01

    There are a limited number of menopause-specific quality-of-life scales for the Turkish population. This study was conducted to evaluate the validity and reliability of the Turkish Utian Quality-of-Life Scale in postmenopausal women. The study group was comprised of 250 postmenopausal women who applied to a training and research hospital's menopause clinic in Turkey. A survey form and the Turkish Utian quality-of-Life Scale were used to collect data, and the Turkish version of Short Form-36 was used to evaluate reliability with an equivalent form. Language-validity, content-validity, and construct-validity methods were used to assess the validity of the scale, and Cronbach's α coefficient calculation and the equivalent-form reliability methods were used to assess the reliability of the scale. The Turkish Utian Quality-of-Life Scale was determined to be a valid and reliable instrument for measuring the quality of life of postmenopausal women. Confirmatory factor analysis demonstrates that the instrument fits well with 23 items and a four-factor model. The Cronbach's α coefficient for the quality-of-life domains were as follows: 0.88 overall, 0.79 health, 0.78 emotional, 0.76 sexual, and 0.75 occupational. Reliability of the instrument was confirmed through significant correlations between scores on the Turkish version of the Utian Quality-of-Life Scale and the Turkish version of the Short Form-36 (r = 0.745, P < 0.001). This research emphasizes that the Turkish Utian Quality-of-Life Scale is reliable and valid in postmenopausal women-it is a useful instrument for measuring quality of life during menopause.

  13. Design, implementation, and psychometric analysis of a scoring instrument for simulated pediatric resuscitation: a report from the EXPRESS pediatric investigators.

    PubMed

    Donoghue, Aaron; Ventre, Kathleen; Boulet, John; Brett-Fleegler, Marisa; Nishisaki, Akira; Overly, Frank; Cheng, Adam

    2011-04-01

    Robustly tested instruments for quantifying clinical performance during pediatric resuscitation are lacking. Examining Pediatric Resuscitation Education through Simulation and Scripting Collaborative was established to conduct multicenter trials of simulation education in pediatric resuscitation, evaluating performance with multiple instruments, one of which is the Clinical Performance Tool (CPT). We hypothesize that the CPT will measure clinical performance during simulated pediatric resuscitation in a reliable and valid manner. Using a pediatric resuscitation scenario as a basis, a scoring system was designed based on Pediatric Advanced Life Support algorithms comprising 21 tasks. Each task was scored as follows: task not performed (0 points); task performed partially, incorrectly, or late (1 point); and task performed completely, correctly, and within the recommended time frame (2 points). Study teams at 14 children's hospitals went through the scenario twice (PRE and POST) with an interposed 20-minute debriefing. Both scenarios for each of eight study teams were scored by multiple raters. A generalizability study, based on the PRE scores, was conducted to investigate the sources of measurement error in the CPT total scores. Inter-rater reliability was estimated based on the variance components. Validity was assessed by repeated measures analysis of variance comparing PRE and POST scores. Sixteen resuscitation scenarios were reviewed and scored by seven raters. Inter-rater reliability for the overall CPT score was 0.63. POST scores were found to be significantly improved compared with PRE scores when controlled for within-subject covariance (F1,15 = 4.64, P < 0.05). The variance component ascribable to rater was 2.4%. Reliable and valid measures of performance in simulated pediatric resuscitation can be obtained from the CPT. Future studies should examine the applicability of trichotomous scoring instruments to other clinical scenarios, as well as performance during actual resuscitations.

  14. The work role functioning questionnaire 2.0 (Dutch version): examination of its reliability, validity and responsiveness in the general working population.

    PubMed

    Abma, Femke I; van der Klink, Jac J L; Bültmann, Ute

    2013-03-01

    The promotion of a sustainable, healthy and productive working life attracts more and more attention. Recently the Work Role Functioning Questionnaire (WRFQ) has been cross-culturally translated and adapted to Dutch. This questionnaire aims to measure the health-related work functioning of workers with health problems. The aim of this study is to evaluate the reliability, validity (including five new items) and responsiveness of the WRFQ 2.0 in the working population. A longitudinal study was conducted among workers. The reliability (internal consistency, test-retest reliability, measurement error), validity (structural validity-factor analysis, construct validity by means of hypotheses testing) and responsiveness of the WRFQ 2.0 were evaluated. A total of N = 553 workers completed the survey. The final WRFQ 2.0 has four subscales and showed very good internal consistency, moderate test-retest reliability, good construct validity and moderate responsiveness in the working population. The WRFQ was able to distinguish between groups with different levels of mental health, physical health, fatigue and need for recovery. A moderate correlation was found between WRFQ and related constructs respectively work ability and work productivity. A weak relationship was found with general self-rated health, work engagement and work involvement. The WRFQ 2.0 is a reliable and valid instrument to measure health-related work functioning in the working population. Further validation in larger samples is recommended, especially for test-retest reliability, responsiveness and the questionnaire's ability to predict the future course of health-related work functioning.

  15. The long-term reliability of static and dynamic quantitative sensory testing in healthy individuals.

    PubMed

    Marcuzzi, Anna; Wrigley, Paul J; Dean, Catherine M; Adams, Roger; Hush, Julia M

    2017-07-01

    Quantitative sensory tests (QSTs) have been increasingly used to investigate alterations in somatosensory function in a wide range of painful conditions. The interpretation of these findings is based on the assumption that the measures are stable and reproducible. To date, reliability of QST has been investigated for short test-retest intervals. The aim of this study was to investigate the long-term reliability of a multimodal QST assessment in healthy people, with testing conducted on 3 occasions over 4 months. Forty-two healthy people were enrolled in the study. Static and dynamic tests were performed, including cold and heat pain threshold (CPT, HPT), mechanical wind-up [wind-up ratio (WUR)], pressure pain threshold (PPT), 2-point discrimination (TPD), and conditioned pain modulation (CPM). Systematic bias, relative reliability and agreement were analysed using repeated measure analysis of variance, intraclass correlation coefficients (ICCs3,1) and SE of the measurement (SEM), respectively. Static QST (CPT, HPT, PPT, and TPD) showed good-to-excellent reliability (ICCs: 0.68-0.90). Dynamic QST (WUR and CPM) showed poor-to-good reliability (ICCs: 0.35-0.61). A significant linear decrease over time was observed for mechanical QST at the back (PPT and TPD) and for CPM (P < 0.01). Static QST were stable over a period of 4 months; however, a small systematic decrease over time has been observed for mechanical QST. Dynamic QST showed considerable variability over time; in particular, CPM using PPT as the test stimulus did not show adequate reliability, suggesting that this test paradigm may be less useful for monitoring individuals over time.

  16. Ultrasound definition of tendon damage in patients with rheumatoid arthritis. Results of a OMERACT consensus-based ultrasound score focussing on the diagnostic reliability.

    PubMed

    Bruyn, George A W; Hanova, Petra; Iagnocco, Annamaria; d'Agostino, Maria-Antonietta; Möller, Ingrid; Terslev, Lene; Backhaus, Marina; Balint, Peter V; Filippucci, Emilio; Baudoin, Paul; van Vugt, Richard; Pineda, Carlos; Wakefield, Richard; Garrido, Jesus; Pecha, Ondrej; Naredo, Esperanza

    2014-11-01

    To develop the first ultrasound scoring system of tendon damage in rheumatoid arthritis (RA) and assess its intraobserver and interobserver reliability. We conducted a Delphi study on ultrasound-defined tendon damage and ultrasound scoring system of tendon damage in RA among 35 international rheumatologists with experience in musculoskeletal ultrasound. Twelve patients with RA were included and assessed twice by 12 rheumatologists-sonographers. Ultrasound examination for tendon damage in B mode of five wrist extensor compartments (extensor carpi radialis brevis and longus; extensor pollicis longus; extensor digitorum communis; extensor digiti minimi; extensor carpi ulnaris) and one ankle tendon (tibialis posterior) was performed blindly, independently and bilaterally in each patient. Intraobserver and interobserver reliability were calculated by κ coefficients. A three-grade semiquantitative scoring system was agreed for scoring tendon damage in B mode. The mean intraobserver reliability for tendon damage scoring was excellent (κ value 0.91). The mean interobserver reliability assessment showed good κ values (κ value 0.75). The most reliable were the extensor digiti minimi, the extensor carpi ulnaris, and the tibialis posterior tendons. An ultrasound reference image atlas of tenosynovitis and tendon damage was also developed. Ultrasound is a reproducible tool for evaluating tendon damage in RA. This study strongly supports a new reliable ultrasound scoring system for tendon damage. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  17. Hand assessment in older adults with musculoskeletal hand problems: a reliability study.

    PubMed

    Myers, Helen L; Thomas, Elaine; Hay, Elaine M; Dziedzic, Krysia S

    2011-01-07

    Musculoskeletal hand pain is common in the general population. This study aims to investigate the inter- and intra-observer reliability of two trained observers conducting a simple clinical interview and physical examination for hand problems in older adults. The reliability of applying the American College of Rheumatology (ACR) criteria for hand osteoarthritis to community-dwelling older adults will also be investigated. Fifty-five participants aged 50 years and over with a current self-reported hand problem and registered with one general practice were recruited from a previous health questionnaire study. Participants underwent a standardised, structured clinical interview and physical examination by two independent trained observers and again by one of these observers a month later. Agreement beyond chance was summarised using Kappa statistics and intra-class correlation coefficients. Median values for inter- and intra-observer reliability for clinical interview questions were found to be "substantial" and "moderate" respectively [median agreement beyond chance (Kappa) was 0.75 (range: -0.03, 0.93) for inter-observer ratings and 0.57 (range: -0.02, 1.00) for intra-observer ratings]. Inter- and intra-observer reliability for physical examination items was variable, with good reliability observed for some items, such as grip and pinch strength, and poor reliability observed for others, notably assessment of altered sensation, pain on resisted movement and judgements based on observation and palpation of individual features at single joints, such as bony enlargement, nodes and swelling. Moderate agreement was observed both between and within observers when applying the ACR criteria for hand osteoarthritis. Standardised, structured clinical interview is reliable for taking a history in community-dwelling older adults with self reported hand problems. Agreement between and within observers for physical examination items is variable. Low Kappa values may have resulted, in part, from a low prevalence of clinical signs and symptoms in the study participants. The decision to use clinical interview and hand assessment variables in clinical practice or further research in primary care should include consideration of clinical applicability and training alongside reliability. Further investigation is required to determine the relationship between these clinical questions and assessments and the clinical course of hand pain and hand problems in community-dwelling older adults.

  18. Developing a reliable signal wire attachment method for rail.

    DOT National Transportation Integrated Search

    2014-11-01

    The goal of this project was to develop a better attachment method for rail signal wires to improve the reliability of signaling : systems. EWI conducted basic research into the failure mode of current attachment methods and developed and tested a ne...

  19. Unified Parkinson's Disease Rating Scale-Motor Exam: inter-rater reliability of advanced practice nurse and neurologist assessments.

    PubMed

    Palmer, Janice L; Coats, Mary A; Roe, Catherine M; Hanko, Shelly M; Xiong, Chengjie; Morris, John C

    2010-06-01

    This paper is a report of a study to establish the inter-rater reliability of advanced practice nurse and neurologist neurological assessments which included ratings with the Unified Parkinson's Disease Rating Scale-Motor Exam. Around the world, advanced practice nurses are performing tasks once completed only by physicians. To promote consumer and provider confidence, it is important to establish that nurse and physician ratings using assessment tools are similar. In addition in research settings, when different raters are used, establishment of inter-rater reliability for study assessments is needed. Advanced practice nurses and neurologists independently recorded findings on neurological examinations of 46 participants in a study conducted between August 2007 and January 2008. An intraclass correlation coefficient was calculated to estimate overall agreement between the nurse and neurologist ratings. Agreement for individual items measured on a dichotomous scale was assessed by calculating Cohen's kappa. There was substantial agreement between advanced practice nurses and neurologists on the mean Unified Parkinson's Disease Rating Scale-Motor Exam ratings (intraclass correlation coefficient = 0.65) and the U.S. National Alzheimer's Coordinating Center Uniform Data Set neurological examination ratings of unremarkable findings (kappa = 0.74) and of gait disorder (kappa = 0.73). Moderate agreement (kappa = 0.53) was reached for the rating of whether all Unified Parkinson's Disease Rating Scale-Motor Exam items were normal. These findings are consistent with studies of the inter-rater agreement of the Unified Parkinson's Disease Rating Scale-Motor Exam and support the conduct of neurological assessments by advanced practice nurses.

  20. Identifying Complementary and Alternative Medicine Usage Information from Internet Resources. A Systematic Review.

    PubMed

    Sharma, Vivekanand; Holmes, John H; Sarkar, Indra N

    2016-08-05

    Identify and highlight research issues and methods used in studying Complementary and Alternative Medicine (CAM) information needs, access, and exchange over the Internet. A literature search was conducted using Preferred Reporting Items for Systematic Reviews and Meta-Analysis guidelines from PubMed to identify articles that have studied Internet use in the CAM context. Additional searches were conducted at Nature.com and Google Scholar. The Internet provides a major medium for attaining CAM information and can also serve as an avenue for conducting CAM related surveys. Based on the literature analyzed in this review, there seems to be significant interest in developing methodologies for identifying CAM treatments, including the analysis of search query data and social media platform discussions. Several studies have also underscored the challenges in developing approaches for identifying the reliability of CAM-related information on the Internet, which may not be supported with reliable sources. The overall findings of this review suggest that there are opportunities for developing approaches for making available accurate information and developing ways to restrict the spread and sale of potentially harmful CAM products and information. Advances in Internet research are yet to be used in context of understanding CAM prevalence and perspectives. Such approaches may provide valuable insights into the current trends and needs in context of CAM use and spread.

  1. IDENTIFYING COMPLEMENTARY AND ALTERNATIVE MEDICINE USAGE INFORMATION FROM INTERNET RESOURCES: A SYSTEMATIC REVIEW

    PubMed Central

    Sharma, V.; Holmes, J.H.; Sarkar, I.N.

    2016-01-01

    SUMMARY Objective Identify and highlight research issues and methods used in studying Complementary and Alternative Medicine (CAM) information needs, access, and exchange over the Internet. Methods A literature search was conducted using Preferred Reporting Items for Systematic Reviews and Meta-Analysis guidelines from PubMed to identify articles that have studied Internet use in the CAM context. Additional searches were conducted at Nature.com and Google Scholar. Results The Internet provides a major medium for attaining CAM information and can also serve as an avenue for conducting CAM related surveys. Based on the literature analyzed in this review, there seems to be significant interest in developing methodologies for identifying CAM treatments, including the analysis of search query data and social media platform discussions. Several studies have also underscored the challenges in developing approaches for identifying the reliability of CAM-related information on the Internet, which may not be supported with reliable sources. The overall findings of this review suggest that there are opportunities for developing approaches for making available accurate information and developing ways to restrict the spread and sale of potentially harmful CAM products and information. Conclusions Advances in Internet research are yet to be used in context of understanding CAM prevalence and perspectives. Such approaches may provide valuable insights into the current trends and needs in context of CAM use and spread. PMID:27352304

  2. Cross-cultural adaptation and psychometric assessment of the Chinese version of the comprehensive needs assessment tool for cancer caregivers (CNAT-C).

    PubMed

    Zhang, Yin-Ping; Zhao, Xin-Shuang; Zhang, Bei; Zhang, Lu-Lu; Ni, Chun-Ping; Hao, Nan; Shi, Chang-Bei; Porr, Caroline

    2015-07-01

    The comprehensive needs assessment tool for cancer caregivers (CNAT-C) is a systematic and comprehensive needs assessment tool for the family caregivers. The purpose of this project was twofold: (1) to adapt the CNAT-C to Mainland China's cultural context and (2) to evaluate the psychometric properties of the newly adapted Chinese CNAT-C. Cross-cultural adaptation of the original CNAT-C was performed according to published guidelines. A pilot study was conducted in Mainland China with 30 Chinese family cancer caregivers. A subsequent validation study was conducted with 205 Chinese cancer caregivers from Mainland China. Construct validity was determined through exploratory and confirmatory factor analyses. Reliability was determined using internal consistency and test-retest reliability. The split-half coefficient for the overall Chinese CNAT-C scale was 0.77. Principal component analysis resulted in an eight-factor structure explaining 68.11 % of the total variance. The comparative fit index (CFI) was 0.91 from the modified model confirmatory factor analysis. The Chi-square divided by degrees of freedom was 1.98, and the root mean squared error of approximation (RMSEA) was 0.079. In relation to the known-group validation, significant differences were found in the Chinese CNAT-C scale according to various caregiver characteristics. Internal consistency was high for the Chinese CNAT-C reaching a Cronbach α value of 0.94. Test-retest reliability was 0.85. The newly adapted Chinese CNAT-C scale possesses adequate validity, test-retest reliability, and internal consistency and therefore may be used to ascertain holistic health and support needs of cancer patients' family caregivers in Mainland China.

  3. Development of family and dietary habits questionnaires: the assessment of family processes, dietary habits and adolescents' impulsiveness in Norwegian adolescents and their parents.

    PubMed

    Bjelland, Mona; Hausken, Solveig E S; Sleddens, Ester F C; Andersen, Lene F; Lie, Hanne C; Finset, Arnstein; Maes, Lea; Melbye, Elisabeth L; Glavin, Kari; Hanssen-Bauer, Merete W; Lien, Nanna

    2014-10-15

    There is a need for valid and comprehensive measures of parental influence on children's energy balance-related behaviours (EBRB). Such measures should be based on a theoretical framework, acknowledging the dynamic and complex nature of interactions occurring within a family. The aim of the Family & Dietary habits (F&D) project was to develop a conceptual framework identifying important and changeable family processes influencing dietary behaviours of 13-15 year olds. A second aim was to develop valid and reliable questionnaires for adolescents and their parents (both mothers and fathers) measuring these processes. A stepwise approach was used; (1) preparation of scope and structure, (2) development of the F&D questionnaires, (3) the conducting of pilot studies and (4) the conducting of validation studies (assessing internal reliability, test-retest reliability and confirmatory factor analysis) using data from a cross-sectional study. The conceptual framework includes psychosocial concepts such as family functioning, cohesion, conflicts, communication, work-family stress, parental practices and parental style. The physical characteristics of the home environment include accessibility and availability of different food items, while family meals are the sociocultural setting included. Individual characteristics measured are dietary intake (vegetables and sugar-sweetened beverages) and adolescents' impulsivity. The F&D questionnaires developed were tested in a test-retest (54 adolescents and 44 of their parents) and in a cross-sectional survey including 440 adolescents (13-15 year olds), 242 mothers and 155 fathers. The samples appear to be relatively representative for Norwegian adolescents and parents. For adolescents, mothers and fathers, the test-retest reliability of the dietary intake, frequencies of (family) meals, work-family stress and communication variables was satisfactory (ICC: 0.53-0.99). Barratt Impulsiveness Scale-Brief (BIS-Brief) was included, assessing adolescent's impulsivity. The internal reliability (Cronbach's alphas: 0.77/0.82) and test-retest reliability values (ICC: 0.74/0.77) of BIS-Brief were good. The conceptual framework developed may be a useful tool in guiding measurement and assessment of the home food environment and family processes related to adolescents' dietary habits, in particular and for EBRBs more generally. The results support the use of the F&D questionnaires as psychometrically sound tools to assess family characteristics and adolescent's impulsivity.

  4. Reliability of the Brazilian version of the Physical Activity Checklist Interview in children.

    PubMed

    Adami, Fernando; Cruciani, Fernanda; Douek, Michelle; Sewell, Carolina Dumit; Mariath, Aline Brandão; Hinnig, Patrícia de Fragas; Freaza, Silvia Rafaela Mascarenhas; Bergamaschi, Denise Pimentel

    2011-04-01

    To assess the reliability of the Lista de Atividades Físicas (Brazilian version of the Physical Activity Checklist Interview) in children. The study is part of a cross-cultural adaptation of the Physical Activity Checklist Interview, conducted with 83 school children aged between seven and ten years, enrolled between the 2nd and 5th grades of primary education in the city of São Paulo, Southeastern Brazil, in 2008. The questionnaire was responded by children through individual interviews. It is comprised of a list of 21 moderate to vigorous physical activities performed on the previous day, it is divided into periods (before, during and after school) and it has a section for interview assessment. This questionnaire enables the quantification of time spent in physical and sedentary activities and the total and weighed metabolic costs. Reliability was assessed by comparing two interviews conducted with a mean interval of three hours. For the interview assessment, data from the first interview and those from an external evaluator were compared. Bland-Altman's proposal, the intraclass correlation coefficient and Lin's concordance correlation coefficient were used to assess reliability. The intraclass correlation coefficient lower limits for the outcomes analyzed varied from 0.84 to 0.96. Precision and agreement varied between 0.83 and 0.97 and between 0.99 and 1, respectively. The line estimated from the pairs of values obtained in both interviews indicates high data precision. The interview item showing the poorest result was the ability to estimate time (fair in 27.7% of interviews). Interview assessment items showed intraclass correlation coefficients between 0.60 and 0.70, except for level of cooperation (0.46). The Brazilian version of the Physical Activity Checklist Interview shows high reliability to assess physical and sedentary activity on the previous day in children.

  5. Exploratory Factor Analysis of NRG Oncology's University of Washington Quality of Life Questionnaire – RTOG Modification

    PubMed Central

    Pugh, Stephanie L.; Wyatt, Gwen; Wong, Raimond K. W.; Sagar, Stephen M.; Yueh, Bevan; Singh, Anurag K.; Yao, Min; Nguyen-Tan, Phuc Felix; Yom, Sue S.; Cardinale, Francis S.; Sultanem, Khalil; Hodson, D. Ian; Krempl, Greg A.; Chavez, Ariel; Yeh, Alexander M.; Bruner, Deborah W.

    2016-01-01

    Context The 15-item University of Washington Quality of Life questionnaire – Radiation Therapy Oncology Group (RTOG) modification (UW-QOL-RTOG modification) has been used in several trials of head and neck cancer conducted by NRG Oncology such as RTOG 9709, RTOG 9901, RTOG 0244, and RTOG 0537. Objectives This study is an exploratory factor analysis (EFA) to establish validity and reliability of the instrument subscales. Methods EFA on the UW-QOL - RTOG modification was conducted using baseline data from NRG Oncology's RTOG 0537, a trial of acupuncture-like transcutaneous electrical nerve stimulation in treating radiation-induced xerostomia. Cronbach's α coefficient was calculated to measure reliability; correlation with the University of Michigan Xerostomia Related Quality of Life Scale (XeQOLS) was used to evaluate concurrent validity; and correlations between consecutive time points were used to assess test-retest reliability. Results The 15-item EFA of the modified tool resulted in 11 items split into 4 factors: mucus, eating, pain, and activities. Cronbach's α ranged from 0.71 to 0.93 for the factors and total score, consisting of all 11 items. There were strong correlations (ρ≥0.60) between consecutive time points and between total score and the XeQOLS total score (ρ>0.65). Conclusion The UW-QOL-RTOG modification is a valid tool that can be used to assess symptom burden of head and neck cancer patients receiving radiation therapy or those who have recently completed radiation. The modified tool has acceptable reliability, concurrent validity, and test-retest reliability in this patient population, as well as the advantage of having being shortened from 15 to 11 items. PMID:27899312

  6. [Estimators of internal consistency in health research: the use of the alpha coefficient].

    PubMed

    da Silva, Franciele Cascaes; Gonçalves, Elizandra; Arancibia, Beatriz Angélica Valdivia; Bento, Gisele Graziele; Castro, Thiago Luis da Silva; Hernandez, Salma Stephany Soleman; da Silva, Rudney

    2015-01-01

    Academic production has increased in the area of health, increasingly demanding high quality in publications of great impact. One of the ways to consider quality is through methods that increase the consistency of data analysis, such as reliability which, depending on the type of data, can be evaluated by different coefficients, especially the alpha coefficient. Based on this, the present review systematically gathers scientific articles produced in the last five years, which in a methodological manner gave the α coefficient psychometric use as an estimator of internal consistency and reliability in the processes of construction, adaptation and validation of instruments. The identification of the studies was conducted systematically in the databases BioMed Central Journals, Web of Science, Wiley Online Library, Medline, SciELO, Scopus, Journals@Ovid, BMJ and Springer, using inclusion and exclusion criteria. Data analyses were performed by means of triangulation, content analysis and descriptive analysis. It was found that most studies were conducted in Iran (f=3), Spain (f=2) and Brazil (f=2). These studies aimed to test the psychometric properties of instruments, with eight studies using the α coefficient to assess reliability and nine for assessing internal consistency. All studies were classified as methodological research when their objectives were analyzed. In addition, four studies were also classified as correlational and one as descriptive-correlational. It can be concluded that though the α coefficient is widely used as one of the main parameters for assessing internal consistency of questionnaires in health sciences, its use as an estimator of trust of the methodology used and internal consistency has some critiques that should be considered.

  7. The Child Adolescent Bullying Scale (CABS): Psychometric evaluation of a new measure.

    PubMed

    Strout, Tania D; Vessey, Judith A; DiFazio, Rachel L; Ludlow, Larry H

    2018-06-01

    While youth bullying is a significant public health problem, healthcare providers have been limited in their ability to identify bullied youths due to the lack of a reliable, and valid instrument appropriate for use in clinical settings. We conducted a multisite study to evaluate the psychometric properties of a new 22-item instrument for assessing youths' experiences of being bullied, the Child Adolescent Bullying Scale (CABS). The 20 items summed to produce the measure's score were evaluated here. Diagnostic performance was assessed through evaluation of sensitivity, specificity, predictive values, and area under receiver operating characteristic (AUROC) curve. A sample of 352 youths from diverse racial, ethnic, and geographic backgrounds (188 female, 159 male, 5 transgender, sample mean age 13.5 years) were recruited from two clinical sites. Participants completed the CABS and existing youth bullying measures. Analyses grounded in classical test theory, including assessments of reliability and validity, item analyses, and principal components analysis, were conducted. The diagnostic performance and test characteristics of the CABS were also evaluated. The CABS is comprised of one component, accounting for 67% of observed variance. Analyses established evidence of internal consistency reliability (Cronbach's α = 0.97), construct and convergent validity. Sensitivity was 84%, specificity was 65%, and the AUROC curve was 0.74 (95% CI: 0.69-0.80). Findings suggest that the CABS holds promise as a reliable, valid tool for healthcare provider use in screening for bullying exposure in the clinical setting. © 2018 Wiley Periodicals, Inc.

  8. Validation of the PedsQL Epilepsy Module: A pediatric epilepsy-specific health-related quality of life measure.

    PubMed

    Modi, Avani C; Junger, Katherine F; Mara, Constance A; Kellermann, Tanja; Barrett, Lauren; Wagner, Janelle; Mucci, Grace A; Bailey, Laurie; Almane, Dace; Guilfoyle, Shanna M; Urso, Lauryn; Hater, Brooke; Hustzi, Heather; Smith, Gigi; Herrmann, Bruce; Perry, M Scott; Zupanc, Mary; Varni, James W

    2017-11-01

    To validate a brief and reliable epilepsy-specific, health-related quality of life (HRQOL) measure in children with various seizure types, treatments, and demographic characteristics. This national validation study was conducted across five epilepsy centers in the United States. Youth 5-18 years and caregivers of youth 2-18 years diagnosed with epilepsy completed the PedsQL Epilepsy Module and additional questionnaires to establish reliability and validity of the epilepsy-specific HRQOL instrument. Demographic and medical data were collected through chart reviews. Factor analysis was conducted, and internal consistency (Cronbach's alphas), test-retest reliability, and construct validity were assessed. Questionnaires were analyzed from 430 children with epilepsy (M age = 9.9 years; range 2-18 years; 46% female; 62% white: non-Hispanic; 76% monotherapy, 54% active seizures) and their caregivers. The final PedsQL Epilepsy Module is a 29-item measure with five subscales (i.e., Impact, Cognitive, Sleep, Executive Functioning, and Mood/Behavior) with parallel child and caregiver reports. Internal consistency coefficients ranged from 0.70-0.94. Construct validity and convergence was demonstrated in several ways, including strong relationships with seizure outcomes, antiepileptic drug (AED) side effects, and well-established measures of executive, cognitive, and emotional/behavioral functioning. The PedsQL Epilepsy Module is a reliable measure of HRQOL with strong evidence of its validity across the epilepsy spectrum in both clinical and research settings. Wiley Periodicals, Inc. © 2017 International League Against Epilepsy.

  9. A psychometric evaluation of the Rorschach comprehensive system's perceptual thinking index.

    PubMed

    Dao, Tam K; Prevatt, Frances

    2006-04-01

    In this study, we investigated evidence for reliability and validity of the Perceptual Thinking Index (PTI; Exner, 2000a, 2000b) among an adult inpatient population. We conducted reliability and validity analyses on 107 patients who met the Diagnostic and Statistical Manual of Mental Disorders (4th ed., text revision; American Psychiatric Association, 2000) criteria for a schizophrenia-spectrum disorder (SSD) or mood disorder with no psychotic features (MD). Results provided support for interrater reliability as well as internal consistency of the PTI. Furthermore, the PTI was an effective index in differentiating SSD patients from patients diagnosed with an MD. Finally, the PTI demonstrated adequate diagnostic statistics that can be useful in the classification of patients diagnosed with SSD and MD. We discuss methodological issues, implications for assessment practice, and directions for future research.

  10. [Implementation of quality of care indicators for third-level public hospitals in Mexico].

    PubMed

    Saturno-Hernández, Pedro Jesús; Martínez-Nicolás, Ismael; Poblano-Verástegui, Ofelia; Vértiz-Ramírez, José de Jesús; Suárez-Ortiz, Erasto Cosme; Magaña-Izquierdo, Manuel; Kawa-Karasik, Simón

    2017-01-01

    To select, pilot test and implement a set of indicators for tertiary public hospitals. Quali-quantitative study in four stages: identification of indicators used internationally; selection and prioritization by utility, feasibility and reliability; exploration of the quality of sources of information in six hospitals; pilot feasibility and reliability, and follow-up measurement. From 143 indicators, 64 were selected and eight were prioritized. The scan revealed sources of information deficient. In the pilot, three indicators were feasible with reliability limited. Has conducted workshops to improve records and sources of information; nine hospitals reported measurements of a quarter. Eight priority indicators could not be measured immediately due to limitations in the data sources for its construction. It is necessary to improve mechanisms of registration and processing of data in this group of hospital.

  11. Initial Development and Psychometric Properties of a New Measure of Substance Use Disorder "Recovery Progression": The Recovery Progression Measure (RPM).

    PubMed

    Elison, Sarah; Davies, Glyn; Ward, Jonathan

    2016-07-28

    There is a growing literature around substance use disorder treatment outcomes measures. Various constructs have been suggested as being appropriate for measuring recovery outcomes, including "recovery capital" and "treatment progression." However, these previously proposed constructs do not measure changes in psychosocial functioning during the recovery process. Therefore, a new psychometric assessment, the "Recovery Progression Measure" (RPM), has been developed to measure this recovery oriented psychosocial change. The aims of this study were to evaluate the reliability and factor structure of the RPM via data collected from 2218 service users being treated for their substance dependence. Data were collected from service users accessing the Breaking Free Online (BFO) substance use disorder treatment and recovery program, which has within its baseline assessment a 36-item psychometric measure previously developed by the authors to assess the six areas of functioning described in the RPM. Reliability analyses and exploratory factor analyses (EFA) were conducted to examine the underlying factor structure of the RPM measure. Internal reliability of the RPM measure was found to be excellent (α > .70) with the overall assessment to have reliability α = .89, with item-total correlations revealing moderate-excellent reliability of individual items. EFA revealed the RPM to contain an underlying factor structure of eight components. This study provides initial data to support the reliability of the RPM as a recovery measure. Further work is now underway to extend these findings, including convergent and predictive validity analyses.

  12. The intra- and inter-rater reliability of five clinical muscle performance tests in patients with and without neck pain

    PubMed Central

    2013-01-01

    Background This study investigates the reliability of muscle performance tests using cost- and time-effective methods similar to those used in clinical practice. When conducting reliability studies, great effort goes into standardising test procedures to facilitate a stable outcome. Therefore, several test trials are often performed. However, when muscle performance tests are applied in the clinical setting, clinicians often only conduct a muscle performance test once as repeated testing may produce fatigue and pain, thus variation in test results. We aimed to investigate whether cervical muscle performance tests, which have shown promising psychometric properties, would remain reliable when examined under conditions similar to those of daily clinical practice. Methods The intra-rater (between-day) and inter-rater (within-day) reliability was assessed for five cervical muscle performance tests in patients with (n = 33) and without neck pain (n = 30). The five tests were joint position error, the cranio-cervical flexion test, the neck flexor muscle endurance test performed in supine and in a 45°-upright position and a new neck extensor test. Results Intra-rater reliability ranged from moderate to almost perfect agreement for joint position error (ICC ≥ 0.48-0.82), the cranio-cervical flexion test (ICC ≥ 0.69), the neck flexor muscle endurance test performed in supine (ICC ≥ 0.68) and in a 45°-upright position (ICC ≥ 0.41) with the exception of a new test (neck extensor test), which ranged from slight to moderate agreement (ICC = 0.14-0.41). Likewise, inter-rater reliability ranged from moderate to almost perfect agreement for joint position error (ICC ≥ 0.51-0.75), the cranio-cervical flexion test (ICC ≥ 0.85), the neck flexor muscle endurance test performed in supine (ICC ≥ 0.70) and in a 45°-upright position (ICC ≥ 0.56). However, only slight to fair agreement was found for the neck extensor test (ICC = 0.19-0.25). Conclusions Intra- and inter-rater reliability ranged from moderate to almost perfect agreement with the exception of a new test (neck extensor test), which ranged from slight to moderate agreement. The significant variability observed suggests that tests like the neck extensor test and the neck flexor muscle endurance test performed in a 45°-upright position are too unstable to be used when evaluating neck muscle performance. PMID:24299621

  13. Perceived rules and accessibility: measurement and mediating role in the association between parental education and vegetable and soft drink intake.

    PubMed

    Gebremariam, Mekdes K; Lien, Nanna; Torheim, Liv Elin; Andersen, Lene F; Melbye, Elisabeth L; Glavin, Kari; Hausken, Solveig E S; Sleddens, Ester F C; Bjelland, Mona

    2016-08-17

    The existence of socioeconomic differences in dietary behaviors is well documented. However, studies exploring the mechanisms behind these differences among adolescents using comprehensive and reliable measures of mediators are lacking. The aims of this study were (a) to assess the psychometric properties of new scales assessing the perceived rules and accessibility related to the consumption of vegetables and soft drinks and (b) to explore their mediating role in the association between parental education and the corresponding dietary behaviors. A cross-sectional survey including 440 adolescents from three counties in Norway (mean age 14.3 years (SD = 0.6)) was conducted using a web-based questionnaire. Principal component analysis, test-retest and internal reliability analysis were conducted. The mediating role of perceived accessibility and perceived rules in the association between parental education and the dietary behaviors was explored using linear regression analyses. Factor analyses confirmed two separate subscales, named "accessibility" and "rules", both for vegetables and soft drinks (factor loadings >0.60). The scales had good internal consistency reliability (0.70-0.87). The test-retest reliability of the scales was moderate to good (0.44-0.62). Parental education was inversely related to the consumption of soft drinks and positively related to the consumption of vegetables. Perceived accessibility and perceived rules related to soft drink consumption were found to mediate the association between parental education and soft drink consumption (47.5 and 8.5 % of total effect mediated). Accessibility of vegetables was found to mediate the association between parental education and the consumption of vegetables (51 % of total effect mediated). The new scales developed in this study are comprehensive and have adequate validity and reliability; they are therefore considered appropriate for use among 13-15 year-olds. Parents, in particular those with a low educational background, should be encouraged to increase the accessibility of vegetables and to decrease the accessibility of soft drinks, in particular during dinner. Enforcing parental rules limiting soft drink intake in families with low parental education also appears relevant.

  14. Development and validation of the Smartphone Addiction Inventory (SPAI).

    PubMed

    Lin, Yu-Hsuan; Chang, Li-Ren; Lee, Yang-Han; Tseng, Hsien-Wei; Kuo, Terry B J; Chen, Sue-Huei

    2014-01-01

    The aim of this study was to develop a self-administered scale based on the special features of smartphone. The reliability and validity of the Smartphone Addiction Inventory (SPAI) was demonstrated. A total of 283 participants were recruited from Dec. 2012 to Jul. 2013 to complete a set of questionnaires, including a 26-item SPAI modified from the Chinese Internet Addiction Scale and phantom vibration and ringing syndrome questionnaire. There were 260 males and 23 females, with ages 22.9 ± 2.0 years. Exploratory factor analysis, internal-consistency test, test-retest, and correlation analysis were conducted to verify the reliability and validity of the SPAI. Correlations between each subscale and phantom vibration and ringing were also explored. Exploratory factor analysis yielded four factors: compulsive behavior, functional impairment, withdrawal and tolerance. Test-retest reliabilities (intraclass correlations  = 0.74-0.91) and internal consistency (Cronbach's α = 0.94) were all satisfactory. The four subscales had moderate to high correlations (0.56-0.78), but had no or very low correlation to phantom vibration/ringing syndrome. This study provides evidence that the SPAI is a valid and reliable, self-administered screening tool to investigate smartphone addiction. Phantom vibration and ringing might be independent entities of smartphone addiction.

  15. Reliability of didactic grades to predict practical skills in an undergraduate dental college in Saudi Arabia.

    PubMed

    Zawawi, Khalid H; Afify, Ahmed R; Yousef, Mohammed K; Othman, Hisham I; Al-Dharrab, Ayman A

    2015-01-01

    This longitudinal study was aimed to investigate the association between didactic grades and practical skills for dental students and whether didactic grades can reliability predict the dental students' practical performance. Didactic and practical grades for graduates from the Faculty of Dentistry, King Abdulaziz University, between the years 2009 and 2011 were collected. Four courses were selected: Dental Anatomy, Operative Dentistry, Prosthodontics, and Orthodontics. Pearson product-moment correlation analyses between didactic and practical scores were conducted. There was only a significant correlation between didactic and practical scores for the Dental Anatomy course (P<0.001). There was also a significant correlation between all four subjects in the didactic scores (P<0.001). Only the scores of male students showed a significant correlation in the Operative Dentistry course (P<0.001). There were no correlations between Orthodontic grades. Moreover, a poor degree of reliability was found between didactic and practical scores for all subjects. Based on the findings of this study, the relationship between didactic grades and practical performance is course specific. Didactic grades do not reliably predict the students' practical skills. Measuring practical performances should be independent from didactic grading.

  16. Reliability of didactic grades to predict practical skills in an undergraduate dental college in Saudi Arabia

    PubMed Central

    Zawawi, Khalid H; Afify, Ahmed R; Yousef, Mohammed K; Othman, Hisham I; Al-Dharrab, Ayman A

    2015-01-01

    Objectives This longitudinal study was aimed to investigate the association between didactic grades and practical skills for dental students and whether didactic grades can reliability predict the dental students’ practical performance. Materials and methods Didactic and practical grades for graduates from the Faculty of Dentistry, King Abdulaziz University, between the years 2009 and 2011 were collected. Four courses were selected: Dental Anatomy, Operative Dentistry, Prosthodontics, and Orthodontics. Pearson product-moment correlation analyses between didactic and practical scores were conducted. Results There was only a significant correlation between didactic and practical scores for the Dental Anatomy course (P<0.001). There was also a significant correlation between all four subjects in the didactic scores (P<0.001). Only the scores of male students showed a significant correlation in the Operative Dentistry course (P<0.001). There were no correlations between Orthodontic grades. Moreover, a poor degree of reliability was found between didactic and practical scores for all subjects. Conclusion Based on the findings of this study, the relationship between didactic grades and practical performance is course specific. Didactic grades do not reliably predict the students’ practical skills. Measuring practical performances should be independent from didactic grading. PMID:25878519

  17. Psychometric evaluation of the Swedish adaptation of the Inventory for Assessing the Process of Cultural Competence Among Healthcare Professionals--Revised (IAPCC-R).

    PubMed

    Olt, Helen; Jirwe, Maria; Gustavsson, Petter; Emami, Azita

    2010-01-01

    The purpose of this study was to describe the translation, adaption, and psychometric evaluation process in relation to validity and reliability of the Swedish version of the instrument, Inventory for Assessing The Process of Cultural Competence Among Healthcare Professionals-Revised (IAPCC-R) following the translation, adaptation, and psychometric evaluation process. Validity tests were conducted on the response processes (N = 15), the content (N = 7), and the internal structure of the instrument (N = 334). Reliability (alpha = .65 for the total scale varying between -.01 and .65 for the different subscales) was evaluated in terms of internal consistency. Results indicated weak validity and reliability though it is difficult to conclude whether this is related to adaptation issues or the original construction.The testing of the response process identified problems in relation to respondents' conceptualization of cultural competence. The test of the content identified a weak correspondence between the items and the underlying model. In addition, a confirmatory factor analysis did not confirm the proposed structure of the instrument. This study concludes that this instrument is not valid and reliable for use with a Swedish population of practicing nurses or nursing students.

  18. Measuring first-line nurse manager work: instrument: development and testing.

    PubMed

    Cadmus, Edna; Wisniewska, Edyta K

    2013-12-01

    The objective of this study was to develop and test a 1st-line nurse manager (FLNM) work instrument to measure categories of work and frequency of activities. First-line nurse managers have been demonstrated to be key contributors in meeting organizational outcomes and patient and nurse satisfaction. Identifying the work of FLNMs is essential to help in the development of prioritization and sequence. The need for an instrument that can measure and categorize the work of FLNMs is indicated. The author-developed instrument was administered as a pilot study to 173 FLNMs in New Jersey. Descriptive statistics were analyzed, and validity and reliability were measured. Content validity was established through 2 focus groups using 10 FLNMs and conducting a survey of 5 chief nursing officers. Reliability was assessed by 13 of 16 FLNM participants using the test/retest method and quantified using percent agreement within a 10-day period. Those items with 70% agreement or more were identified as reliable and retained on the instrument. The content validity of the instrument is strong; further refinement and testing of the tool are indicated to improve the reliability and generalizability across multiple populations of leaders and settings.

  19. Applying Resource Utilization Groups (RUG-III) in Hong Kong nursing homes.

    PubMed

    Chou, Kee-Lee; Chi, Iris; Leung, Joe C B

    2008-01-01

    Resource Utilization Groups III (RUG-III) is a case-mix system developed in the United States for categorization of nursing home residents and the financing of residential care services. In Hong Kong, RUG-III is based on several board groups of residents. The aim of this study was to examine the reliability and validity of the RUG-III in Hong Kong nursing homes. A cross-sectional survey was conducted in seven residential facilities operated by one agency. Residents ( N = 1,127) were assessed by the Minimum Data Set (MDS) and nursing as well as auxiliary staff care times were recorded within 2 weeks before or after the completion of MDS assessment. Forty-five out 1,127 residents were re-interviewed by an independent assessor to assess the inter-rater reliability. The inter-rater reliability of MDS assessment was excellent (kappa = 0.76) and the original RUG-III accounted for about 30 per cent of nursing staff time. Results provide preliminary evidence to support that RUG-III is a reliable and valid case-mix system for Hong Kong nursing homes, but future studies must be explored to reduce the variance of resource use explained by this case-mix system.

  20. Development of the Teen Oral Health-Related Quality of Life Instrument.

    PubMed

    Wright, Wanda G; Spiro, Avron; Jones, Judith A; Rich, Sharron E; Garcia, Raul I

    2017-03-01

    The aim of this study was to develop the Teen Oral Health-Related Quality of Life instrument (TOQOL) and demonstrate its validity and reliability in a diverse sample of 13-18-year-old adolescents. A total of 363 adolescents aged 13-18 years participated in this cross sectional study. Oral screening examinations were conducted to collect oral health status data. Adolescents completed the TOQOL and a generic measure of health-related quality of life, the PedsQL. The psychometric properties of the TOQOL were evaluated in terms of face, content, convergent, concurrent and discriminant validity in addition to internal reliability. The 16-item TOQOL covers five domains: Physical functioning, Role functioning, Social functioning, Oral problems, and Emotional functioning. The total scale and subscales showed satisfactory reliability with Cronbach alpha ranging from 0.75 to 0.92. TOQOL scores showed significant associations with perceived oral health status and the PedsQL (convergent validity) and discriminated well between adolescents with caries and adolescents who were caries free (discriminate validity). The TOQOL is a valid and reliable oral health-related quality of life measurement that can be recommended for self-report in adolescents aged 13-18 years. © 2016 American Association of Public Health Dentistry.

  1. Validity and test-retest reliability of the six-spot step test in persons after stroke.

    PubMed

    Arvidsson Lindvall, Mialinn; Anderzén-Carlsson, Agneta; Appelros, Peter; Forsberg, Anette

    2018-06-06

    After stroke, asymmetric weight distribution is common with decreased balance control in standing and walking. The six-spot step test (SSST) includes a 5-m walk during which one leg shoves wooden blocks out of circles marked on the floor, thus assessing the ability to take load on each leg. The aim of the present study was to investigate the convergent and discriminant validity and test-retest reliability of the SSST in persons with stroke. Eighty-one participants were included. A cross-sectional study was performed, in which the SSST was conducted twice, 3-7 days apart. Validity was investigated using measures of dynamic balance and walking. Reliability was assessed using intraclass correlation coefficient, standard error of the measurement (SEM), and smallest real difference (SRD). The convergent validity was strong to moderate, and the test-retest reliability was good. The SEM% was 14.7%, and the SRD% was 40.8% based on the mean of four walks shoving twice with the paretic and twice with the non-paretic leg. Values on random measurement error were high affecting the use of the SSST for follow-up evaluations but the SSST can be a complementary measure of gait and balance.

  2. [Intraclass reliability of the Alberta Infant Motor Scale in the Brazilian version].

    PubMed

    Silva, Larissa Paiva; Maia, Polyana Candeia; Lopes, Márcia Maria Coelho Oliveira; Cardoso, Maria Vera Lúcia Moreira Leitão

    2013-10-01

    This study had as its objective to analyze the intraclass reliability of the Alberta Infant Motor Scale (AIMS), in the Brazilian version, in preterm and term infants. It was a methodological study, conducted from November 2009 to April 2010, with 50 children receiving care in two public institutions in Fortaleza, Ceará, Brazil. Children were grouped according to gestational age as preterm and term, and evaluated by three evaluators in the communication laboratory of a public institution or at home. The intraclass correlation indices for the categories prone, supine, sitting and standing ranged from 0.553 to 0.952; most remained above 0.800, except for the standing category of the third evaluator, in which the index was 0.553. As for the total score and percentile, rates ranged from 0.843 to 0.954. The scale proved to be a reliable instrument for assessing gross motor performance of Brazilian children, particularly in Ceará, regardless of gestational age at birth.

  3. Home Lighting Assessment for Clients With Low Vision

    PubMed Central

    Bhorade, Anjali; Gordon, Mae; Hollingsworth, Holly; Engsberg, Jack E.; Baum, M. Carolyn

    2013-01-01

    OBJECTIVE. The goal was to develop an objective, comprehensive, near-task home lighting assessment for older adults with low vision. METHOD. A home lighting assessment was developed and tested with older adults with low vision. Interrater and test–retest reliability studies were conducted. Clinical utility was assessed by occupational therapists with expertise in low vision rehabilitation. RESULTS. Interrater reliability was high (intraclass correlation coefficient [ICC] = .83–1.0). Test–retest reliability was moderate (ICC = .67). Responses to a Clinical Utility Feedback Form developed for this study indicated that the Home Environment Lighting Assessment (HELA) has strong clinical utility. CONCLUSION. The HELA provides a structured tool to describe the quantitative and qualitative aspects of home lighting environments where near tasks are performed and can be used to plan lighting interventions. The HELA has the potential to affect assessment and intervention practices of rehabilitation professionals in the area of low vision and improve near-task performance of people with low vision. PMID:24195901

  4. Test of understanding of vectors: A reliable multiple-choice vector concept test

    NASA Astrophysics Data System (ADS)

    Barniol, Pablo; Zavala, Genaro

    2014-06-01

    In this article we discuss the findings of our research on students' understanding of vector concepts in problems without physical context. First, we develop a complete taxonomy of the most frequent errors made by university students when learning vector concepts. This study is based on the results of several test administrations of open-ended problems in which a total of 2067 students participated. Using this taxonomy, we then designed a 20-item multiple-choice test [Test of understanding of vectors (TUV)] and administered it in English to 423 students who were completing the required sequence of introductory physics courses at a large private Mexican university. We evaluated the test's content validity, reliability, and discriminatory power. The results indicate that the TUV is a reliable assessment tool. We also conducted a detailed analysis of the students' understanding of the vector concepts evaluated in the test. The TUV is included in the Supplemental Material as a resource for other researchers studying vector learning, as well as instructors teaching the material.

  5. Toward a TQM Paradigm: Using SERVQUAL to Measure Library Service Quality.

    ERIC Educational Resources Information Center

    Coleman, Vicki; And Others

    1997-01-01

    Texas A&M University's Evans Library conducted a survey (SERVQUAL) to measure service quality in terms of tangibles (appearance of facilities, equipment, personnel, and communication materials), reliability, responsiveness, assurance, and empathy. Discrepancies between expectations and perceptions were found in reliability, responsiveness,…

  6. Development of dual solid cryogens for high reliability refrigeration system

    NASA Technical Reports Server (NTRS)

    Caren, R. P.; Coston, R. M.

    1967-01-01

    High reliability solid cryogen refrigeration system consists of a container initially filled with a solid cryogen which is coupled thermally to an infrared detector by means of a link of high thermal conductivity extending from a heat exchanger within the cryogen container.

  7. [Validation of the Polish version of The Authentic Leadership Questionnaire for the of evaluation purpose of nursing management staff in national hospital wards].

    PubMed

    Sierpińska, Lidia

    2013-09-01

    The Authentic Leadership Questionnaire (ALQ) is a standardized research instrument for the evaluation of individual elements of leader's conduct which contribute to the authentic leadership. The application of this questionnaire in Polish conditions required to carry out the validation process. The aim of the study was to evaluate of validity and reliability of the Polish version of the American research instrument for the needs of evaluation of authenticity of leadership of the nursing management in Polish hospitals. The study covered 286 nurses (143 head nurses and 143 of their subordinates) employed in 45 hospitals in Poland. Theoretical validity of the instrument was evaluated using Fisher's transformation (r-Person correlation coefficient), while the criterion validity of the ALQ was evaluated using rho-Spearman correlation coefficient and the BOHIPSZO questionnaire. The reliability of the ALQ was assessed by means of the Cronbach-alpha coefficient. The ALQ questionnaire applied for the evaluation of authenticity of leadership of the nursing management in Polish hospital wards shows an acceptable theoretical and criterion validity and reliability (Cronbach-alpha coefficient 0.80). The Polish version of the ALQ is valid and reliable, and may be applied in studies concerning the evaluation of authenticity of leadership of the nursing management in Polish hospital wards.

  8. Validity, Reliability and Feasibility of the Eating Behavior Pattern Questionnaire (EBPQ) among Iranian Female Students

    PubMed Central

    Dehghan, Parvin; Asghari-Jafarabadi, Mohammad; Salekzamani, Shabnam

    2015-01-01

    Background: The aim of this study was to assess the validity, reliability and feasibility of eating behavior pattern questionnaire (EBPQ) in female university students. Methods: In this study, after forward-backward translation, the questionnaire was reviewed by a panel of nutritionists and a psychologist and further thirty participants for the content validity measurement. The translated and modified questionnaire was completed by 225 female students of Tabriz University in 2013. Principle axis factoring, confirmatory factor analysis and known group analysis were conducted for construct, convergent and discriminant validity. Internal consistency and test–retest reliability were assessed by Cronbach’s α coefficient and intra-class correlation coefficient (ICC). Ceiling and floor effects were also performed for evaluating the feasibility of the instrument. Results: By using exploratory factor analysis, nine factors were extracted. Confirmatory factor analysis confirmed the convergent validity. Cronbach ’s αand ICC were ranged between 0.55 to 0.78 and 0.67 to 0.89, respectively. The significant difference for some three subscales between diabetes and healthy subjects determined the discriminant validity. No ceiling and floor effects were found. Conclusion: Our findings demonstrate the initial validity, reliability and feasibility of the Iranian version of EBPQ as a useful tool for eating behavior studies in young females. PMID:26290828

  9. [Reliability and validity of a Mexican version of the Pro Children Project questionnaire].

    PubMed

    Ochoa-Meza, Gerardo; Sierra, Juan Carlos; Pérez-Rodrigo, Carmen; Aranceta Bartrina, Javier; Esparza-Del Villar, Óscar A

    2014-08-01

    To determine the test-retest reliability, the internal consistency, and the predictive validity of the constructs of the Mexican version of the Pro Children Project questionnaire (PCHP) for assessing personal and environmental factors related to fruit and vegetable intake in 10-12 year-old schoolchildren. Test-retest design with a 14 days interval. A sample of 957 children completed the questionnaire with 82 items. The study was conducted at eight primary schools in 2012 in Ciudad Juarez, Chihuahua, Mexico. For all fruit constructs and vegetable constructs, the test-retest reliability was moderate (intraclass correlation coefficient (ICC) > 0.60). Cronbach s alpha values were from moderate to high (range of 0.54 to 0.92) similar to those in the original study. Values for predictive validity ranged from moderate to good with Spearman correlations between 0.23 and 0.60 for personal factors and between 0.14 and 0.40 for environmental factors. The results of the Mexican version of the PCHP questionnaire provide a sufficient reliability and validity for assessing personal and environmental factors of fruit and vegetable intake in 10-12 year old schoolchildren. Finally, implications to administer this instrument in scholar settings and guidelines for futures studies are discussed. Copyright AULA MEDICA EDICIONES 2014. Published by AULA MEDICA. All rights reserved.

  10. Rasch Analysis of the Geriatric Depression Scale--Short Form

    ERIC Educational Resources Information Center

    Chiang, Karl S.; Green, Kathy E.; Cox, Enid O.

    2009-01-01

    Purpose: The purpose of this study was to examine scale dimensionality, reliability, invariance, targeting, continuity, cutoff scores, and diagnostic use of the Geriatric Depression Scale-Short Form (GDS-SF) over time with a sample of 177 English-speaking U.S. elders. Design and Methods: An item response theory, Rasch analysis, was conducted with…

  11. An Integrated Approach to Teaching Literature in an EFL Classroom

    ERIC Educational Resources Information Center

    Yimwilai, Supaporn

    2015-01-01

    This research studied the effectiveness of the integrated approach in English as a Foreign Language (EFL) classrooms and how it related to students' 1) achievements, 2) critical thinking skills, and 3) attitudes toward reading literature. To ensure that the results were accurate and reliable, the experiment was conducted in two different regions.…

  12. Reliability and Validity of the Vietnamese Vineland Adaptive Behavior Scales with Preschool-Age Children

    ERIC Educational Resources Information Center

    Goldberg, Michael R.; Dill, Charles A.; Shin, Jin Y.; Nhan, Nguyen Viet

    2009-01-01

    This study was conducted to examine an adaptation of the Vineland Adaptive Behavior Scale (VABS) [Sparrow, S. S., Balla, D. A., & Cicchetti, D. V. (1984). "The Vineland Adaptive Behavior Scales." Circle Pines, MN: America Guidance Service; Sparrow, S. S., Balla, D. A., & Cicchetti, D. V. (2005). "Vineland Adaptive Behavior…

  13. A Perceptual Measure of Children's Developmental Somatotypic Preferences.

    ERIC Educational Resources Information Center

    Portnoy, Enid P.; Gardner, Julie M.

    Somatotyping is a term that has evolved for the reliable recognition of the expected relationship between body type and personality traits. Using a somatotypic measure, a study was conducted to identify the developmental changes in children's attraction preferences within their own peer groups, as tested in kindergarten, third, and sixth grades.…

  14. Current Status of the Matson Evaluation of Drug Side Effects (MEDS)

    ERIC Educational Resources Information Center

    Matson, Johnny L.; Cervantes, Paige E.

    2013-01-01

    The Matson Evaluation of Drug Side Effects (MEDS) is currently the best established and most researched measure of drug side effects in the intellectual disability (ID) literature. Initial research was conducted on its psychometric properties such as reliability and validity. More recent research studies have used the measure to determine the…

  15. Quantifying Children's Aggregate (Dietary and Residential) Exposure and Dose to Permethin: Application and Evaluation of EPA's Probabilistic SHED-Multimedia Model

    EPA Science Inventory

    Reliable, evaluated human exposure and dose models are important for understanding the health risks from chemicals. A case study focusing on permethrin was conducted because of this insecticide’s widespread use and potential health effects. SHEDS-Multimedia was applied to estimat...

  16. Standardization of the Functional Assessment and Intervention Program (FAIP) with Children Who Have Externalizing Behaviors

    ERIC Educational Resources Information Center

    Hartwig, Laurie; Heathfield, Lora Tuesday; Jenson, William R.

    2004-01-01

    The purpose of this study was to develop standardization data for the Functional Assessment Intervention Program (FAIP; University of Utah, Utah State University, & Utah State Office of Education, 1999), a computerized, functional behavioral assessment expert system. Reliability, validity, and utility analyses were conducted with students serving…

  17. Measurement Properties of Two Innovative Item Formats in a Computer-Based Test

    ERIC Educational Resources Information Center

    Wan, Lei; Henly, George A.

    2012-01-01

    Many innovative item formats have been proposed over the past decade, but little empirical research has been conducted on their measurement properties. This study examines the reliability, efficiency, and construct validity of two innovative item formats--the figural response (FR) and constructed response (CR) formats used in a K-12 computerized…

  18. The Development of the Motivation for Critical Reasoning in Online Discussions Inventory (MCRODI)

    ERIC Educational Resources Information Center

    Zhang, Tianyi; Koehler, Matthew J.; Spatariu, Alexandru

    2009-01-01

    This study was conducted to develop an inventory that measures students' motivation to engage in critical reasoning in online discussions. Inventory items were developed based on theoretical frameworks and then tested on 168 participants. Using exploratory factor analysis, test-retest reliability, and internal consistency, twenty-two items were…

  19. Effect of cultural practices and fungicide treatments on the severity of Phytophthora root rot of blueberries grown in Mississippi

    USDA-ARS?s Scientific Manuscript database

    Phytophthora root rot is an important disease of blueberries, especially those grown in areas with poor drainage. Reliable cultural and chemical management strategies are needed for control of this disease. Two studies were conducted to evaluate the effects of cultural practices and fungicide treat...

  20. A Spanish Version of the Expectations about Counseling Questionnaire: Translation and Validation.

    ERIC Educational Resources Information Center

    Buhrke, Robin A.; Jorge, Michael

    1992-01-01

    Summarizes two studies conducted for the development and validation of a Spanish version of the Expectations about Counseling (EAC) questionnaire. Administered English and Spanish versions to bilingual university students and bilingual nonstudents. Results suggest that the Spanish version of the EAC is a reliable and valid translation for students…

  1. Measuring Mindfulness in Summer Camp Staff

    ERIC Educational Resources Information Center

    Gillard, Ann; Roark, Mark F.; Nyaga, Lewis Ramsey Kanyiba; Bialeschki, M. Deborah

    2011-01-01

    Examining mindfulness in a non-clinical and non-therapeutic setting such as a summer camp is an area of growing interest. Our study tested three mindfulness scales with staff in a summer camp setting, and we conducted preliminary reliability and validity analyses for any modifications needed in the scales. Results indicated two major findings: (a)…

  2. Evaluating the Validity and Reliability of a Student Self-Advocacy Teacher Rating Scale

    ERIC Educational Resources Information Center

    Walick, Christopher M.

    2017-01-01

    Self-advocacy skills are critical to high school and post-secondary success. Unfortunately, students with disabilities often times struggle with self-advocacy. While there are effective, evidence-based programs to teach self-advocacy skills, there are few scales that directly measure self-advocacy. The current research study was conducted to…

  3. Psychometric Properties of Scores from the Web-based LibQUAL+ Study of Perceptions of Library Service Quality.

    ERIC Educational Resources Information Center

    Cook, Colleen; Thompson, Bruce

    2001-01-01

    Investigated the psychometric integrity of scores from the LibQUAL+ evaluation of perceived library service quality conducted by ARL (Association of Research Libraries). Examines score structure, score reliability, score correlation and concurrent validity coefficients, scale means, and scale standardized norms, and considers the potential of the…

  4. Early-Stage Research & Development | Transportation Research | NREL

    Science.gov Websites

    thermal conductivity of packed copper wire used in electric-drive vehicle motor applications provides a research on thermal management in copper-wound electric motors is helping to improve the performance and reliability of electric-drive vehicles. Photo by Kevin Bennion, NREL. Anisotropic Thermal Measurement Study

  5. Multi-Source Evaluation of Interpersonal and Communication Skills of Family Medicine Residents

    ERIC Educational Resources Information Center

    Leung, Kai-Kuen; Wang, Wei-Dan; Chen, Yen-Yuan

    2012-01-01

    There is a lack of information on the use of multi-source evaluation to assess trainees' interpersonal and communication skills in Oriental settings. This study is conducted to assess the reliability and applicability of assessing the interpersonal and communication skills of family medicine residents by patients, peer residents, nurses, and…

  6. Motivational Orientations of Senior Citizens Participating in the Elderhostel Program.

    ERIC Educational Resources Information Center

    Bova, Breda Murphy

    A study was conducted (1) to analyze the Educational Participation Scale (EPS) factor patterns derived from a sample of senior citizens in order to contribute additional reliability and validity data to the instrument; and (2) to look at reasons that have influenced senior citizens to pursue educational activities, specifically the Elderhostel…

  7. [Job rotation in anaesthesiological care: impacts on knowledge and learning].

    PubMed

    Jordan, Silvia; Brauner, Elisabeth

    2008-04-01

    Job rotation in anaesthesiological care is explored in this article. Based on discussions of 'high reliability organizations', and based on current theory in social and organizational psychology, we empirically investigated the impact of job rotation on knowledge management and learning. The study was conducted at the University Hospital of Innsbruck during the job training period of novice nurse anaesthetists. Qualitative interviews were conducted as well as a questionnaire administered. Data were collected between September 2003 and June 2005. Observational and interview data were combined with a questionnaire study to assess transactive memory and cooperation using a mixed-method design. Qualitative data were analyzed using GABEK, a computer-supported content analysis system; quantitative data were analyzed statistically with SPSS. Results indicate that job rotation had both positive and negative effects on knowledge and learning. On the one hand, job rotation can foster flexibility and awareness of a person's own fallibility and lack of knowledge. On the other hand, trust, group cohesion, and social meta-knowledge can be hampered by constant rotation. Consequently, stabilization and change need equal consideration when designing work in high reliability organizations.

  8. A reliability and mass perspective of SP-100 Stirling cycle lunar-base powerplant designs

    NASA Technical Reports Server (NTRS)

    Bloomfield, Harvey S.

    1991-01-01

    The purpose was to obtain reliability and mass perspectives on selection of space power system conceptual designs based on SP-100 reactor and Stirling cycle power-generation subsystems. The approach taken was to: (1) develop a criterion for an acceptable overall reliability risk as a function of the expected range of emerging technology subsystem unit reliabilities; (2) conduct reliability and mass analyses for a diverse matrix of 800-kWe lunar-base design configurations employing single and multiple powerplants with both full and partial subsystem redundancy combinations; and (3) derive reliability and mass perspectives on selection of conceptual design configurations that meet an acceptable reliability criterion with the minimum system mass increase relative to reference powerplant design. The developed perspectives provided valuable insight into the considerations required to identify and characterize high-reliability and low-mass lunar-base powerplant conceptual design.

  9. Reliability Analysis and Standardization of Spacecraft Command Generation Processes

    NASA Technical Reports Server (NTRS)

    Meshkat, Leila; Grenander, Sven; Evensen, Ken

    2011-01-01

    center dot In order to reduce commanding errors that are caused by humans, we create an approach and corresponding artifacts for standardizing the command generation process and conducting risk management during the design and assurance of such processes. center dot The literature review conducted during the standardization process revealed that very few atomic level human activities are associated with even a broad set of missions. center dot Applicable human reliability metrics for performing these atomic level tasks are available. center dot The process for building a "Periodic Table" of Command and Control Functions as well as Probabilistic Risk Assessment (PRA) models is demonstrated. center dot The PRA models are executed using data from human reliability data banks. center dot The Periodic Table is related to the PRA models via Fault Links.

  10. Validation of Medical Tourism Service Quality Questionnaire (MTSQQ) for Iranian Hospitals.

    PubMed

    Qolipour, Mohammad; Torabipour, Amin; Khiavi, Farzad Faraji; Malehi, Amal Saki

    2017-03-01

    Assessing service quality is one of the basic requirements to develop the medical tourism industry. There is no valid and reliable tool to measure service quality of medical tourism. This study aimed to determine the reliability and validity of a Persian version of medical tourism service quality questionnaire for Iranian hospitals. To validate the medical tourism service quality questionnaire (MTSQQ), a cross-sectional study was conducted on 250 Iraqi patients referred to hospitals in Ahvaz (Iran) from 2015. To design a questionnaire and determine its content validity, the Delphi Technique (3 rounds) with the participation of 20 medical tourism experts was used. Construct validity of the questionnaire was assessed through exploratory and confirmatory factor analysis. Reliability was assessed using Cronbach's alpha coefficient. Data were analyzed by Excel 2007, SPSS version18, and Lisrel l8.0 software. The content validity of the questionnaire with CVI=0.775 was confirmed. According to exploratory factor analysis, the MTSQQ included 31 items and 8 dimensions (tangibility, reliability, responsiveness, assurance, empathy, exchange and travel facilities, technical and infrastructure facilities and safety and security). Construct validity of the questionnaire was confirmed, based on the goodness of fit quantities of model (RMSEA=0.032, CFI= 0.98, GFI=0.88). Cronbach's alpha coefficient was 0.837 and 0.919 for expectation and perception questionnaire. The results of the study showed that the medical tourism SERVQUAL questionnaire with 31 items and 8 dimensions was a valid and reliable tool to measure service quality of medical tourism in Iranian hospitals.

  11. Spanish version validation of the Marihuana Motives Measure in a drug-consuming adolescent sample.

    PubMed

    Matali Costa, Josep; Simons, J; Pardo, M; Lleras, M; Pérez, A; Andión, O

    2018-01-15

    Cannabis is the illicit drug mostly widely consumed by adolescents in Spain. The understanding of consumption motives is an important factor for intervention. In Spain, there are no available instruments for their evaluation, hence, the goal of this paper is to study the psychometric properties of the Marihuana Motives Measure (MMM) in a sample of adolescent consumers. Firstly, translation and back-translation was performed. A total of 228 adolescent consumers of cannabis were evaluated. Factorial analysis was conducted, and the reliability of the total scores and of each scale of the questionnaire was studied through Cronbach's alpha. Test-retest reliability was analyzed through interclass correlations. Validity evidence of the MMM was examined through correlations between current cannabis use, subjective consumption effects measured with the Addiction Research Center Inventory (ARCI), and personality measured with the Millon Adolescent Clinical Inventory (MACI). High reliability was observed in total score of the MMM (Cronbach α = .86), and high and moderate reliability for each of the five factors obtained in the factorial analysis of the MMM, Social = .82, Enhancement = .72, Coping = .83, Expansion = .74, and Conformity = .64. Significant correlations were also observed between cannabis consumption motives and subjective effects, and between consumption motives and personality. The Spanish version of the MMM shows a similar factorial structure as the one obtained by the original author, and its measures are reliable and valid for the study of cannabis consumption motives in adolescent consumer population.

  12. Assessment of the intraobserver and interobserver reliability of a communicating vessels volumeter to measure wrist-hand volume.

    PubMed

    de Carvalho, Rogério Mendonca; Perez, Maria Del Carmen Janerio; Miranda, Fausto

    2012-10-01

    Traditional volumetry based on Archimedes' principle is the gold standard for the measurement of limb volume, but the routine use of this technique is discouraged because of several disadvantages. The purpose of this study was to evaluate intraobserver and interobserver reliability of direct measurements of wrist-hand volume using a new communicating vessels volumeter based on Pascal's law. A reliability study was conducted. To evaluate the reliability of the communicating vessels volumeter in generating measurements, 30 hands of 15 participants (9 women, 6 men) were measured 3 times each by 3 observers, totaling 270 volumetric results. Measurement time was short (X =3 minutes 42 seconds). The intraclass correlation coefficient (ICC) was .9977 for observer 1 and .9976 for observers 2 and 3. The interobserver ICC was .9998. The standard error of measurement was about 3 mL for all observers; the interobserver result was 1 mL. The interrater coefficient of variance (CV) was 1.15% for the series of 9 measurements collected for each segment; the intrarater CV was 1.20%. Limitations No swollen hands were measured, and measurements were not compared with the gold standard technique. Thus, accuracy of the new volumeter was not determined in this study. A new device has been developed for plethysmography of the extremities, and the results of its use to measure the volume of the wrist-hand segment were reliable in both intraobserver and interobserver analyses.

  13. Reliability and number of trials of Y Balance Test in adolescent athletes.

    PubMed

    Linek, Pawel; Sikora, Damian; Wolny, Tomasz; Saulicz, Edward

    2017-10-01

    The Star Excursion Balance Test (SEBT) is commonly used to evaluate dynamic equilibrium. The Y Balance Test (Y-BT) is a shortened version of the SEBT where a Y- Balance Kit is commonly used. To date, research concerning the protocol and reliability of the SEBT and Y-BT has been conducted only for adults. The aim of the study was to assess the protocol (the necessary number of trials to stabilize the results) and reliability of the Y-BT in adolescent athletes. One-way repeated-measures analysis of variance (ANOVA) and reliability study. The sample of 38 athletes (mean age: 15.6 years) was selected from a football club. A Y-Balance test kit was applied for the evaluation of dynamic balance. The analysis used the values normalized to the relative length of the lower limbs. After six attempts, three consecutive ones achieved stability for all directions and both extremities (p > 0.05). The intraclass correlation coefficient (ICC 3,1 ), standard error of measurement and minimal detectable change values for the three attempts ranged from 0.57 to 0.82, from 3 to less than 6% and from 7.68 to 13.7%, respectively. In the study of adolescent dynamic equilibrium using the Y-BT, it is recommended to perform nine attempts (including six trial attempts and three measurements). In order to increase reliability it is recommended that the average of the three measured attempts is analysed. Copyright © 2017 Elsevier Ltd. All rights reserved.

  14. A singlechip-computer-controlled conductivity meter based on conductance-frequency transformation

    NASA Astrophysics Data System (ADS)

    Chen, Wenxiang; Hong, Baocai

    2005-02-01

    A portable conductivity meter controlled by singlechip computer was designed. The instrument uses conductance-frequency transformation method to measure the conductivity of solution. The circuitry is simple and reliable. Another feature of the instrument is that the temperature compensation is realised by changing counting time of the timing counter. The theoretical based and the usage of temperature compensation are narrated.

  15. Thermal conductivity, bulk properties, and thermal stratigraphy of silicic tuffs from the upper portion of hole USW-G1, Yucca Mountain, Nye County, Nevada

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lappin, A.R.; VanBuskirk, R.G.; Enniss, D.O.

    1982-03-01

    Thermal-conductivity and bulk-property measurements were made on welded and nonwelded silicic tuffs from the upper portion of Hole USW-G1, located near the southwestern margin of the Nevada Test Site. Bulk-property measurements were made by standard techniques. Thermal conductivities were measured at temperatures as high as 280{sup 0}C, confining pressures to 10 MPa, and pore pressures to 1.5 MPa. Extrapolation of measured saturated conductivities to zero porosity suggests that matrix conductivity of both zeolitized and devitrified tuffs is independent of stratigraphic position, depth, and probably location. This fact allows development of a thermal-conductivity stratigraphy for the upper portion of Hole G1.more » Estimates of saturated conductivities of zeolitized nonwelded tuffs and devitrified tuffs below the water table appear most reliable. Estimated conductivities of saturated densely welded devitrified tuffs above the water table are less reliable, due to both internal complexity and limited data presently available. Estimation of conductivity of dewatered tuffs requires use of different air thermal conductivities in devitrified and zeolitized samples. Estimated effects of in-situ fracturing generally appear negligible.« less

  16. Improving fMRI reliability in presurgical mapping for brain tumours.

    PubMed

    Stevens, M Tynan R; Clarke, David B; Stroink, Gerhard; Beyea, Steven D; D'Arcy, Ryan Cn

    2016-03-01

    Functional MRI (fMRI) is becoming increasingly integrated into clinical practice for presurgical mapping. Current efforts are focused on validating data quality, with reliability being a major factor. In this paper, we demonstrate the utility of a recently developed approach that uses receiver operating characteristic-reliability (ROC-r) to: (1) identify reliable versus unreliable data sets; (2) automatically select processing options to enhance data quality; and (3) automatically select individualised thresholds for activation maps. Presurgical fMRI was conducted in 16 patients undergoing surgical treatment for brain tumours. Within-session test-retest fMRI was conducted, and ROC-reliability of the patient group was compared to a previous healthy control cohort. Individually optimised preprocessing pipelines were determined to improve reliability. Spatial correspondence was assessed by comparing the fMRI results to intraoperative cortical stimulation mapping, in terms of the distance to the nearest active fMRI voxel. The average ROC-r reliability for the patients was 0.58±0.03, as compared to 0.72±0.02 in healthy controls. For the patient group, this increased significantly to 0.65±0.02 by adopting optimised preprocessing pipelines. Co-localisation of the fMRI maps with cortical stimulation was significantly better for more reliable versus less reliable data sets (8.3±0.9 vs 29±3 mm, respectively). We demonstrated ROC-r analysis for identifying reliable fMRI data sets, choosing optimal postprocessing pipelines, and selecting patient-specific thresholds. Data sets with higher reliability also showed closer spatial correspondence to cortical stimulation. ROC-r can thus identify poor fMRI data at time of scanning, allowing for repeat scans when necessary. ROC-r analysis provides optimised and automated fMRI processing for improved presurgical mapping. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  17. Using Reliability and Item Analysis to Evaluate a Teacher-Developed Test in Educational Measurement and Evaluation

    ERIC Educational Resources Information Center

    Quaigrain, Kennedy; Arhin, Ato Kwamina

    2017-01-01

    Item analysis is essential in improving items which will be used again in later tests; it can also be used to eliminate misleading items in a test. The study focused on item and test quality and explored the relationship between difficulty index (p-value) and discrimination index (DI) with distractor efficiency (DE). The study was conducted among…

  18. Measures of Success: A Survey of Selected Vocational and Technical Education Programs in Florida which Train Students in Occupations Requiring Licenses.

    ERIC Educational Resources Information Center

    Florida State Advisory Council on Vocational and Technical Education, Tallahassee.

    A study of 13 vocational and technical education programs in Florida was conducted which represented an attempt to identify valid and reliable sources of data whereby some vocational programs might be evaluated in specified terms of effectiveness. The programs selected for study were among those which require graduating students to pass licensing…

  19. Deliberate Self-Harm within an International Community Sample of Young People: Comparative Findings from the Child & Adolescent Self-Harm in Europe (CASE) Study

    ERIC Educational Resources Information Center

    Madge, Nicola; Hewitt, Anthea; Hawton, Keith; de Wilde, Erik Jan; Corcoran, Paul; Fekete, Sandor; van Heeringen, Kees; De Leo, Diego; Ystgaard, Mette

    2008-01-01

    Background: Deliberate self-harm among young people is an important focus of policy and practice internationally. Nonetheless, there is little reliable comparative international information on its extent or characteristics. We have conducted a seven-country comparative community study of deliberate self-harm among young people. Method: Over 30,000…

  20. Application and Reliability of the Retrospective Interview Procedure to Trace Physical Activity Patterns in Master Athletes and Nonactive Older Adults

    ERIC Educational Resources Information Center

    MacDonald, Dany J.; Horton, Sean; Kraemer, Krista; Weir, Patricia; Deakin, Janice M.; Cote, Jean

    2009-01-01

    This paper reports the results of two studies. The purpose of the first study was to determine if lifestyle variables and past involvement in physical activity was related to current activity levels in master athletes and sedentary older adults. Retrospective interviews were conducted with 12 master athletes and 12 sedentary older adults. Results…

Top