Reliability program requirements for aeronautical and space system contractors
NASA Technical Reports Server (NTRS)
1987-01-01
General reliability program requirements for NASA contracts involving the design, development, fabrication, test, and/or use of aeronautical and space systems including critical ground support equipment are prescribed. The reliability program requirements require (1) thorough planning and effective management of the reliability effort; (2) definition of the major reliability tasks and their place as an integral part of the design and development process; (3) planning and evaluating the reliability of the system and its elements (including effects of software interfaces) through a program of analysis, review, and test; and (4) timely status indication by formal documentation and other reporting to facilitate control of the reliability program.
NASA Technical Reports Server (NTRS)
Feldstein, J. F.
1977-01-01
Failure data from 16 commercial spacecraft were analyzed to evaluate failure trends, reliability growth, and effectiveness of tests. It was shown that the test programs were highly effective in ensuring a high level of in-orbit reliability. There was only a single catastrophic problem in 44 years of in-orbit operation on 12 spacecraft. The results also indicate that in-orbit failure rates are highly correlated with unit and systems test failure rates. The data suggest that test effectiveness estimates can be used to guide the content of a test program to ensure that in-orbit reliability goals are achieved.
Integrating Formal Methods and Testing 2002
NASA Technical Reports Server (NTRS)
Cukic, Bojan
2002-01-01
Traditionally, qualitative program verification methodologies and program testing are studied in separate research communities. None of them alone is powerful and practical enough to provide sufficient confidence in ultra-high reliability assessment when used exclusively. Significant advances can be made by accounting not only tho formal verification and program testing. but also the impact of many other standard V&V techniques, in a unified software reliability assessment framework. The first year of this research resulted in the statistical framework that, given the assumptions on the success of the qualitative V&V and QA procedures, significantly reduces the amount of testing needed to confidently assess reliability at so-called high and ultra-high levels (10-4 or higher). The coming years shall address the methodologies to realistically estimate the impacts of various V&V techniques to system reliability and include the impact of operational risk to reliability assessment. Combine formal correctness verification, process and product metrics, and other standard qualitative software assurance methods with statistical testing with the aim of gaining higher confidence in software reliability assessment for high-assurance applications. B) Quantify the impact of these methods on software reliability. C) Demonstrate that accounting for the effectiveness of these methods reduces the number of tests needed to attain certain confidence level. D) Quantify and justify the reliability estimate for systems developed using various methods.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vanderwiel, Scott A; Wilson, Alyson G; Graves, Todd L
Both the U. S. Department of Defense (DoD) and Department of Energy (DOE) maintain weapons stockpiles: items like bullets, missiles and bombs that have already been produced and are being stored until needed. Ideally, these stockpiles maintain high reliability over time. To assess reliability, a surveillance program is implemented, where units are periodically removed from the stockpile and tested. The most definitive tests typically destroy the weapons so a given unit is tested only once. Surveillance managers need to decide how many units should be tested, how often they should be tested, what tests should be done, and how themore » resulting data are used to estimate the stockpile's current and future reliability. These issues are particularly critical from a planning perspective: given what has already been observed and our understanding of the mechanisms of stockpile aging, what is an appropriate and cost-effective surveillance program? Surveillance programs are costly, broad, and deep, especially in the DOE, where the US nuclear weapons surveillance program must 'ensure, through various tests, that the reliability of nuclear weapons is maintained' in the absence of full-system testing (General Accounting Office, 1996). The DOE program consists primarily of three types of tests: nonnuclear flight tests, that involve the actual dropping or launching of a weapon from which the nuclear components have been removed; and nonnuclear and nuclear systems laboratory tests, which detect defects due to aging, manufacturing, and design of the nonnuclear and nuclear portions of the weapons. Fully integrated analysis of the suite of nuclear weapons surveillance data is an ongoing area of research (Wilson et al., 2007). This paper introduces a simple model that captures high-level features of stockpile reliability over time and can be used to answer broad policy questions about surveillance programs. Our intention is to provide a framework that generates tractable answers that integrate expert knowledge and high-level summaries of surveillance data to allow decision-making about appropriate trade-offs between the cost of data and the precision of stockpile reliability estimates.« less
2012-06-01
executed a concerted effort to employ reliability standards and testing from the design phase through fielding. Reliability programs remain standard...performed flight test engineer duties on several developmental flight test programs and served as Chief Engineer for a flight test squadron. Major...Quant is an acquisition professional with over 250 flight test hours in various aircraft, including the F-16, Airborne Laser, and HH-60. She holds a
Selenide isotope generator for the Galileo mission. Reliability program plan
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1978-10-01
The reliability program plan for the Selenide Isotope Generator (SIG) program is presented. It delineates the specific tasks that will be accomplished by Teledyne Energy Systems and its suppliers during design, development, fabrication and test of deliverable Radioisotopic Thermoelectric Generators (RTG), Electrical Heated Thermoelectric Generators (ETG) and associated Ground Support Equipment (GSE). The Plan is formulated in general accordance with procedures specified in DOE Reliability Engineering Program Requirements Publication No. SNS-2, dated June 17, 1974. The Reliability Program Plan presented herein defines the total reliability effort without further reference to Government Specifications. The reliability tasks to be accomplished are delineatedmore » herein and become the basis for contract compliance to the extent specified in the SIG contract Statement of Work.« less
Design for reliability: NASA reliability preferred practices for design and test
NASA Technical Reports Server (NTRS)
Lalli, Vincent R.
1994-01-01
This tutorial summarizes reliability experience from both NASA and industry and reflects engineering practices that support current and future civil space programs. These practices were collected from various NASA field centers and were reviewed by a committee of senior technical representatives from the participating centers (members are listed at the end). The material for this tutorial was taken from the publication issued by the NASA Reliability and Maintainability Steering Committee (NASA Reliability Preferred Practices for Design and Test. NASA TM-4322, 1991). Reliability must be an integral part of the systems engineering process. Although both disciplines must be weighed equally with other technical and programmatic demands, the application of sound reliability principles will be the key to the effectiveness and affordability of America's space program. Our space programs have shown that reliability efforts must focus on the design characteristics that affect the frequency of failure. Herein, we emphasize that these identified design characteristics must be controlled by applying conservative engineering principles.
Lunar Regenerative Fuel Cell (RFC) Reliability Testing for Assured Mission Success
NASA Technical Reports Server (NTRS)
Bents, David J.
2009-01-01
NASA's Constellation program has selected the closed cycle hydrogen oxygen Polymer Electrolyte Membrane (PEM) Regenerative Fuel Cell (RFC) as its baseline solar energy storage system for the lunar outpost and manned rover vehicles. Since the outpost and manned rovers are "human-rated," these energy storage systems will have to be of proven reliability exceeding 99 percent over the length of the mission. Because of the low (TRL=5) development state of the closed cycle hydrogen oxygen PEM RFC at present, and because there is no equivalent technology base in the commercial sector from which to draw or infer reliability information from, NASA will have to spend significant resources developing this technology from TRL 5 to TRL 9, and will have to embark upon an ambitious reliability development program to make this technology ready for a manned mission. Because NASA would be the first user of this new technology, NASA will likely have to bear all the costs associated with its development.When well-known reliability estimation techniques are applied to the hydrogen oxygen RFC to determine the amount of testing that will be required to assure RFC unit reliability over life of the mission, the analysis indicates the reliability testing phase by itself will take at least 2 yr, and could take up to 6 yr depending on the number of QA units that are built and tested and the individual unit reliability that is desired. The cost and schedule impacts of reliability development need to be considered in NASA's Exploration Technology Development Program (ETDP) plans, since life cycle testing to build meaningful reliability data is the only way to assure "return to the moon, this time to stay, then on to Mars" mission success.
NASA Technical Reports Server (NTRS)
Bavuso, Salvatore J.; Rothmann, Elizabeth; Dugan, Joanne Bechta; Trivedi, Kishor S.; Mittal, Nitin; Boyd, Mark A.; Geist, Robert M.; Smotherman, Mark D.
1994-01-01
The Hybrid Automated Reliability Predictor (HARP) integrated Reliability (HiRel) tool system for reliability/availability prediction offers a toolbox of integrated reliability/availability programs that can be used to customize the user's application in a workstation or nonworkstation environment. HiRel consists of interactive graphical input/output programs and four reliability/availability modeling engines that provide analytical and simulative solutions to a wide host of reliable fault-tolerant system architectures and is also applicable to electronic systems in general. The tool system was designed to be compatible with most computing platforms and operating systems, and some programs have been beta tested, within the aerospace community for over 8 years. Volume 1 provides an introduction to the HARP program. Comprehensive information on HARP mathematical models can be found in the references.
NASA program decisions using reliability analysis.
NASA Technical Reports Server (NTRS)
Steinberg, A.
1972-01-01
NASA made use of the analytical outputs of reliability people to make management decisions on the Apollo program. Such decisions affected the amount of the incentive fees, how much acceptance testing was necessary, how to optimize development testing, whether to approve engineering changes, and certification of flight readiness. Examples of such analysis are discussed and related to programmatic decisions.-
Software reliability experiments data analysis and investigation
NASA Technical Reports Server (NTRS)
Walker, J. Leslie; Caglayan, Alper K.
1991-01-01
The objectives are to investigate the fundamental reasons which cause independently developed software programs to fail dependently, and to examine fault tolerant software structures which maximize reliability gain in the presence of such dependent failure behavior. The authors used 20 redundant programs from a software reliability experiment to analyze the software errors causing coincident failures, to compare the reliability of N-version and recovery block structures composed of these programs, and to examine the impact of diversity on software reliability using subpopulations of these programs. The results indicate that both conceptually related and unrelated errors can cause coincident failures and that recovery block structures offer more reliability gain than N-version structures if acceptance checks that fail independently from the software components are available. The authors present a theory of general program checkers that have potential application for acceptance tests.
Lifetime Reliability Evaluation of Structural Ceramic Parts with the CARES/LIFE Computer Program
NASA Technical Reports Server (NTRS)
Nemeth, Noel N.; Powers, Lynn M.; Janosik, Lesley A.; Gyekenyesi, John P.
1993-01-01
The computer program CARES/LIFE calculates the time-dependent reliability of monolithic ceramic components subjected to thermomechanical and/or proof test loading. This program is an extension of the CARES (Ceramics Analysis and Reliability Evaluation of Structures) computer program. CARES/LIFE accounts for the phenomenon of subcritical crack growth (SCG) by utilizing the power law, Paris law, or Walker equation. The two-parameter Weibull cumulative distribution function is used to characterize the variation in component strength. The effects of multiaxial stresses are modeled using either the principle of independent action (PIA), Weibull's normal stress averaging method (NSA), or Batdorf's theory. Inert strength and fatigue parameters are estimated from rupture strength data of naturally flawed specimens loaded in static, dynamic, or cyclic fatigue. Two example problems demonstrating cyclic fatigue parameter estimation and component reliability analysis with proof testing are included.
Analysis of whisker-toughened CMC structural components using an interactive reliability model
NASA Technical Reports Server (NTRS)
Duffy, Stephen F.; Palko, Joseph L.
1992-01-01
Realizing wider utilization of ceramic matrix composites (CMC) requires the development of advanced structural analysis technologies. This article focuses on the use of interactive reliability models to predict component probability of failure. The deterministic William-Warnke failure criterion serves as theoretical basis for the reliability model presented here. The model has been implemented into a test-bed software program. This computer program has been coupled to a general-purpose finite element program. A simple structural problem is presented to illustrate the reliability model and the computer algorithm.
Reliability Technology to Achieve Insertion of Advanced Packaging (RELTECH) program
NASA Astrophysics Data System (ADS)
Fayette, Daniel F.; Speicher, Patricia; Stoklosa, Mark J.; Evans, Jillian V.; Evans, John W.; Gentile, Mike; Pagel, Chuck A.; Hakim, Edward
1993-08-01
A joint military-commercial effort to evaluate multichip module (MCM) structures is discussed. The program, Reliability Technology to Achieve Insertion of Advanced Packaging (RELTECH), has been designed to identify the failure mechanisms that are possible in MCM structures. The RELTECH test vehicles, technical assessment task, product evaluation plan, reliability modeling task, accelerated and environmental testing, and post-test physical analysis and failure analysis are described. The information obtained through RELTECH can be used to address standardization issues, through development of cost effective qualification and appropriate screening criteria, for inclusion into a commercial specification and the MIL-H-38534 general specification for hybrid microcircuits.
Analysis of strain gage reliability in F-100 jet engine testing at NASA Lewis Research Center
NASA Technical Reports Server (NTRS)
Holanda, R.
1983-01-01
A reliability analysis was performed on 64 strain gage systems mounted on the 3 rotor stages of the fan of a YF-100 engine. The strain gages were used in a 65 hour fan flutter research program which included about 5 hours of blade flutter. The analysis was part of a reliability improvement program. Eighty-four percent of the strain gages survived the test and performed satisfactorily. A post test analysis determined most failure causes. Five failures were caused by open circuits, three failed gages showed elevated circuit resistance, and one gage circuit was grounded. One failure was undetermined.
Reliability Technology to Achieve Insertion of Advanced Packaging (RELTECH) program
NASA Technical Reports Server (NTRS)
Fayette, Daniel F.; Speicher, Patricia; Stoklosa, Mark J.; Evans, Jillian V.; Evans, John W.; Gentile, Mike; Pagel, Chuck A.; Hakim, Edward
1993-01-01
A joint military-commercial effort to evaluate multichip module (MCM) structures is discussed. The program, Reliability Technology to Achieve Insertion of Advanced Packaging (RELTECH), has been designed to identify the failure mechanisms that are possible in MCM structures. The RELTECH test vehicles, technical assessment task, product evaluation plan, reliability modeling task, accelerated and environmental testing, and post-test physical analysis and failure analysis are described. The information obtained through RELTECH can be used to address standardization issues, through development of cost effective qualification and appropriate screening criteria, for inclusion into a commercial specification and the MIL-H-38534 general specification for hybrid microcircuits.
Graduate nurses' evaluation of mentorship: Development of a new tool.
Tiew, Lay Hwa; Koh, Catherine S L; Creedy, Debra K; Tam, W S W
2017-07-01
Develop and test an instrument to measure graduate-nurses' perceptions of a structured mentorship program. New graduate nurses may experience difficulties in the transition from student to practitioner. Mentoring is commonly used to support graduates. However, there is a lack of published tools measuring graduate nurses' perceptions of mentorship. As mentoring is resource intensive, development and testing of a validated tool are important to assist in determining program effectiveness. A pretest-posttest interventional design was used. Following a critical review of literature and content experts' input, the 10-item National University Hospital Mentorship Evaluation (NUH ME) instrument was tested with a convenience sample of 83 graduate nurses. Psychometric tests included internal reliability, stability, content validity, and factor analysis. Changed scores were evaluated using paired samples t-test. Seventy-three graduates (88%) out of a possible 83 completed the pre-and post-program survey. Internal reliability was excellent with a Cronbach's alpha of 0.92. Test-retest reliability was stable over time (ICC=0.81). Exploratory factor analysis supported a 1-factor solution explaining 58.2% of variance. Paired samples t-test showed statistical significance between the pre- and post-program scores (p<0.001). The NUH-ME measure was found to be valid and reliable. Confirmatory Factor Analysis of the tool with different groups of nursing graduates is required. Mentorship programs can be an effective recruitment and retention strategy, but are also resource intensive. Measuring new graduates' perceptions of mentoring contributes to program relevance in addressing their personal, professional and clinical skill development needs. As mentoring engages a diverse range of mentors, feedback through measurement may also positively alter organizational learning culture. Copyright © 2017. Published by Elsevier Ltd.
2015-11-01
collected. We determined that the methodologies were valid and the data were reliable for our purposes. In addition, we interviewed DOD officials and...of contracts and cost of labor involved in preparing program documentation, to arrive at the estimates for savings. To validate the data used in the...studies to be reasonable, and the data were sufficiently reliable for our purposes. We interviewed officials from DOD and 5 of the 12 Test Program
Metrics for the National SCADA Test Bed Program
DOE Office of Scientific and Technical Information (OSTI.GOV)
Craig, Philip A.; Mortensen, J.; Dagle, Jeffery E.
2008-12-05
The U.S. Department of Energy Office of Electricity Delivery and Energy Reliability (DOE-OE) National SCADA Test Bed (NSTB) Program is providing valuable inputs into the electric industry by performing topical research and development (R&D) to secure next generation and legacy control systems. In addition, the program conducts vulnerability and risk analysis, develops tools, and performs industry liaison, outreach and awareness activities. These activities will enhance the secure and reliable delivery of energy for the United States. This report will describe metrics that could be utilized to provide feedback to help enhance the effectiveness of the NSTB Program.
ERIC Educational Resources Information Center
Barnette, J. Jackson
2005-01-01
An Excel program developed to assist researchers in the determination and presentation of confidence intervals around commonly used score reliability coefficients is described. The software includes programs to determine confidence intervals for Cronbachs alpha, Pearson r-based coefficients such as those used in test-retest and alternate forms…
NASA Technical Reports Server (NTRS)
Sproles, Darrell W.; Bavuso, Salvatore J.
1994-01-01
The Hybrid Automated Reliability Predictor (HARP) integrated Reliability (HiRel) tool system for reliability/availability prediction offers a toolbox of integrated reliability/availability programs that can be used to customize the user's application in a workstation or nonworkstation environment. HiRel consists of interactive graphical input/output programs and four reliability/availability modeling engines that provide analytical and simulative solutions to a wide host of highly reliable fault-tolerant system architectures and is also applicable to electronic systems in general. The tool system was designed at the outset to be compatible with most computing platforms and operating systems and some programs have been beta tested within the aerospace community for over 8 years. This document is a user's guide for the HiRel graphical postprocessor program HARPO (HARP Output). HARPO reads ASCII files generated by HARP. It provides an interactive plotting capability that can be used to display alternate model data for trade-off analyses. File data can also be imported to other commercial software programs.
Effect of Processing Parameters on Reliability of VARTM/SCRIMP Composite Panels - Phase 1
2007-07-01
used in this program (Hess and Beach, 2000). The structural risks associated with new FRP composite ship structures can be mitigated by...reliability calibration of new designs. This program focuses on addressing the first and second tasks outlined above. 1.2. Phase I - Objectives The...Accomplishments: Tension Testing An optimized geometry for tension coupon testing was developed for marine grade composites. The new geometry reduces
Psychometric Properties of the Adolescent Health Concern Inventory: The Persian Version
Baheiraei, Azam; Ahmadi, Fazlollah; Foroushani, Abbas Rahimi; Ghofranipour, Fazlollah; Weiler, Robert M
2013-01-01
Objective It is important to consider the health concerns of adolescents before developing and implementing public health promotion or health education curriculum programs aimed at ameliorating priority health problems experienced by adolescents. The aim of this study was to test the psychometric properties of the original Adolescent Health Concern Inventory (AHCI) for use with an Iranian population. Methods This was a methodological study in which 50 adolescents with age range of 14-18 years were selected using convenience sampling. The translation and cultural adaptation process of The AHCI followed recognized and established guidelines. The face and content validity was established by analyzing feedback solicited from teenagers and professionals with expertise in health, sociology and psychology. Reliability was examined using test-retest and Cronbach's alpha for internal consistency reliability. Kappa and McNemar tests were used to examine test-retest reliability for each item. Results Minor cultural differences were identified and resolved during the translation process and determining the validity of the checklist. Results from Kappa and McNemar tests indicate a high degree of test-retest reliability. Internal consistency reliability as measured by Cronbach's alpha for the subscales were between 0.68 and 0.87 with total instrument reliability of 0.96 indicating considerable overall reliability. Conclusion The Persian version of the AHCI appears valid and reliable. Hence, it can be used for filling a gap in identifying the adolescents’ health concerns in the research and community settings and school health education programs in Iran to design appropriate interventions. PMID:23682249
Photomultiplier tube reliability study for the HEAO program
NASA Technical Reports Server (NTRS)
Richardson, C.
1974-01-01
Results concerning the research on photomultiplier tubes required for the HEAO program are reported. The general specifications are discussed for providing a series of tests for helping the operational reliability of its application, and for permitting comparison of performance of similar types, from various manufacturers.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-06-10
... standards that require the use of the best available technology for ensuring the full reliability and... available technology for ensuring the full reliability and accuracy of urine drug tests, while reflecting..., cutoffs, specimen validity, collection, collection devices, and testing. II. Solicitation of Comments: As...
Application of IUS equipment and experience to orbit transfer vehicles of the 90's
NASA Astrophysics Data System (ADS)
Bangsund, E.; Keeney, J.; Cowgill, E.
1985-10-01
This paper relates experiences with the IUS program and the application of that experience to Future Orbit Transfer Vehicles. More specifically it includes the implementation of the U.S. Air Force Space Division high reliability parts standard (SMASO STD 73-2C) and the component/system test standard (MIL-STD-1540A). Test results from the parts and component level testing and the resulting system level test program for fourteen IUS flight vehicles are discussed. The IUS program has had the highest compliance with these standards and thus offers a benchmark of experience for future programs demanding extreme reliability. In summary, application of the stringent parts standard has resulted in fewer failures during testing and the stringent test standard has eliminated design problems in the hardware. Both have been expensive in costs and schedules, and should be applied with flexibility.
Markov chains for testing redundant software
NASA Technical Reports Server (NTRS)
White, Allan L.; Sjogren, Jon A.
1988-01-01
A preliminary design for a validation experiment has been developed that addresses several problems unique to assuring the extremely high quality of multiple-version programs in process-control software. The procedure uses Markov chains to model the error states of the multiple version programs. The programs are observed during simulated process-control testing, and estimates are obtained for the transition probabilities between the states of the Markov chain. The experimental Markov chain model is then expanded into a reliability model that takes into account the inertia of the system being controlled. The reliability of the multiple version software is computed from this reliability model at a given confidence level using confidence intervals obtained for the transition probabilities during the experiment. An example demonstrating the method is provided.
NASA reliability preferred practices for design and test
NASA Technical Reports Server (NTRS)
1991-01-01
Given here is a manual that was produced to communicate within the aerospace community design practices that have contributed to NASA mission success. The information represents the best technical advice that NASA has to offer on reliability design and test practices. Topics covered include reliability practices, including design criteria, test procedures, and analytical techniques that have been applied to previous space flight programs; and reliability guidelines, including techniques currently applied to space flight projects, where sufficient information exists to certify that the technique will contribute to mission success.
NASA Technical Reports Server (NTRS)
Bavuso, Salvatore J.; Rothmann, Elizabeth; Mittal, Nitin; Koppen, Sandra Howell
1994-01-01
The Hybrid Automated Reliability Predictor (HARP) integrated Reliability (HiRel) tool system for reliability/availability prediction offers a toolbox of integrated reliability/availability programs that can be used to customize the user's application in a workstation or nonworkstation environment. HiRel consists of interactive graphical input/output programs and four reliability/availability modeling engines that provide analytical and simulative solutions to a wide host of highly reliable fault-tolerant system architectures and is also applicable to electronic systems in general. The tool system was designed at the outset to be compatible with most computing platforms and operating systems, and some programs have been beta tested within the aerospace community for over 8 years. This document is a user's guide for the HiRel graphical preprocessor Graphics Oriented (GO) program. GO is a graphical user interface for the HARP engine that enables the drawing of reliability/availability models on a monitor. A mouse is used to select fault tree gates or Markov graphical symbols from a menu for drawing.
Reliability Growth Testing Effectiveness.
1984-01-01
interface boundaries. f. Test facility and equipment descriptions and requirements. g. Procedures and timing for corrective acticns. Uh . Blocks of tme and...apporLionment, FMEA and stress analysis. Instead, reiiability "growth management provides a means of viewing all the reliability program activities in an...A VENDOR SURVEILLANCE 8 A A R GROWTH ESTING. A R PROGRAM4 C B A A NORMALIZED INCREASE 0 2.5% 25% 60 % IN ACQUISITION COST RELATIVE CHANGE IN 1:1 4:1
Pilot testing of SHRP 2 reliability data and analytical products: Minnesota.
DOT National Transportation Integrated Search
2015-01-01
The Minnesota pilot site has undertaken an effort to test data and analytical tools developed through the Strategic Highway Research Program (SHRP) 2 Reliability focus area. The purpose of these tools is to facilitate the improvement of travel time r...
Pilot testing of SHRP 2 reliability data and analytical products: Washington.
DOT National Transportation Integrated Search
2014-07-30
The second Strategic Highway Research Program (SHRP 2) addresses the challenges of moving people and goods efficiently and safely on the nations highways. In its Reliability focus area, the research emphasizes improving the reliability of highway ...
Forward Skirt Structural Testing on the Space Launch System (SLS) Program
NASA Technical Reports Server (NTRS)
Lohrer, J. D.; Wright, R. D.
2016-01-01
Structural testing was performed to evaluate heritage forward skirts from the Space Shuttle program for use on the NASA Space Launch System (SLS) program. Testing was needed because SLS ascent loads are 35% higher than Space Shuttle loads. Objectives of testing were to determine margins of safety, demonstrate reliability, and validate analytical models. Testing combined with analysis was able to show heritage forward skirts were acceptable to use on the SLS program.
Assessment of NDE reliability data
NASA Technical Reports Server (NTRS)
Yee, B. G. W.; Couchman, J. C.; Chang, F. H.; Packman, D. F.
1975-01-01
Twenty sets of relevant nondestructive test (NDT) reliability data were identified, collected, compiled, and categorized. A criterion for the selection of data for statistical analysis considerations was formulated, and a model to grade the quality and validity of the data sets was developed. Data input formats, which record the pertinent parameters of the defect/specimen and inspection procedures, were formulated for each NDE method. A comprehensive computer program was written and debugged to calculate the probability of flaw detection at several confidence limits by the binomial distribution. This program also selects the desired data sets for pooling and tests the statistical pooling criteria before calculating the composite detection reliability. An example of the calculated reliability of crack detection in bolt holes by an automatic eddy current method is presented.
COPES Report: System Reliability Study.
ERIC Educational Resources Information Center
Foothill-De Anza Community Coll. District, Los Altos Hills, CA.
The study examines the reliability of the Community College Occupational Programs Evaluation System (COPES). The COPES process is a system for evaluating program strengths and needs. A two-way test, college self-appraisal with third party validation of the self-appraisal, is utilized to assist community colleges in future institutional planning…
NASA Technical Reports Server (NTRS)
Lathrop, J. W.; Davis, C. W.; Royal, E.
1982-01-01
The use of accelerated testing methods in a program to determine the reliability attributes of terrestrial silicon solar cells is discussed. Different failure modes are to be expected when cells with and without encapsulation are subjected to accelerated testing and separate test schedules for each are described. Unencapsulated test cells having slight variations in metallization are used to illustrate how accelerated testing can highlight different diffusion related failure mechanisms. The usefulness of accelerated testing when applied to encapsulated cells is illustrated by results showing that moisture related degradation may be many times worse with some forms of encapsulation than with no encapsulation at all.
Space reliability technology - A historical perspective
NASA Technical Reports Server (NTRS)
Cohen, H.
1984-01-01
The progressive improvements in reliability of launch vehicles is traced from the Vanguard rocket to the STS. The Vanguard, built with minimal redundancy and a high mass ratio, was used as an operational vehicle midway through its test program in an attempt to meet the perceived challenge represented by the Sputnik. The fourth Vanguard failed due to inadequate contamination prevention and lack of inspection ports. Automatic firing sequences were adopted for the Titan rockets, which were an order of magnitude larger than the Vanguard and therefore had room for interior inspections. Qualification testing and reporting were introduced for components, along with X ray inspection of fuel tank welds. Dual systems were added for flight critical components when the Titan became man-rated for the Gemini program. Designs incorporated full failure mode effects and criticality analyses for the Apollo program, which exposed the limits of applicability of numerical reliability models. Fault tree analyses and program milestone reviews were initiated. The worth of man-in-the-loop in space activities for reliability was demonstrated with the rescue of Skylab after solar panel and meteoroid shield failures. It is now the reliability of the payload, rather than the vehicle, that is questioned for Shuttle launches.
Nightingale, Steven C; Miller, Stuart; Turner, Anthony
2013-06-01
Ice hockey, like most sports, uses fitness testing to assess athletes. This study reviews the current commonly used fitness testing protocols for ice hockey players, discussing their predictive values and reliability. It also discusses a range of less commonly used measures and limitations in current testing protocols. The article concludes with a proposed testing program suitable for ice hockey players.
Pilot testing of SHRP 2 reliability data and analytical products: Florida. [supporting datasets
DOT National Transportation Integrated Search
2014-01-01
SHRP 2 initiated the L38 project to pilot test products from five of the programs completed projects. The products support reliability estimation and use based on data analyses, analytical techniques, and decision-making framework. The L38 project...
Fixture tests bellows reliability through repetitive pressure/temperature cycling
NASA Technical Reports Server (NTRS)
Levinson, C.
1967-01-01
Fixture explores the reliability of bellows used in precision in inertial systems. The fixture establishes the ability of the bellows to withstand repetitive over-stress pressure cycling at elevated temperatures. It is applicable in quality control and reliability programs.
Time-dependent reliability analysis of ceramic engine components
NASA Technical Reports Server (NTRS)
Nemeth, Noel N.
1993-01-01
The computer program CARES/LIFE calculates the time-dependent reliability of monolithic ceramic components subjected to thermomechanical and/or proof test loading. This program is an extension of the CARES (Ceramics Analysis and Reliability Evaluation of Structures) computer program. CARES/LIFE accounts for the phenomenon of subcritical crack growth (SCG) by utilizing either the power or Paris law relations. The two-parameter Weibull cumulative distribution function is used to characterize the variation in component strength. The effects of multiaxial stresses are modeled using either the principle of independent action (PIA), the Weibull normal stress averaging method (NSA), or the Batdorf theory. Inert strength and fatigue parameters are estimated from rupture strength data of naturally flawed specimens loaded in static, dynamic, or cyclic fatigue. Two example problems demonstrating proof testing and fatigue parameter estimation are given.
The NASA Electronic Parts and Packaging (NEPP) Program: Insertion of New Electronics Technologies
NASA Technical Reports Server (NTRS)
LaBel, Kenneth A.; Sampson, Michael J.
2007-01-01
This viewgraph presentation gives an overview of NASA Electronic Parts and Packaging (NEPP) Program's new electronics technology trends. The topics include: 1) The Changing World of Radiation Testing of Memories; 2) Even Application-Specific Tests are Costly!; 3) Hypothetical New Technology Part Qualification Cost; 4) Where we are; 5) Approaching FPGAs as a More Than a "Part" for Reliability; 6) FPGAs Beget Novel Radiation Test Setups; 7) Understanding the Complex Radiation Data; 8) Tracking Packaging Complexity and Reliability for FPGAs; 9) Devices Supporting the FPGA Need to be Considered; 10) Summary of the New Electronic Technologies and Insertion into Flight Programs Workshop; and 11) Highlights of Panel Notes and Comments
New International Program to Asses the Reliability of Emerging Nondestructive Techniques (PARENT)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Prokofiev, Iouri; Cumblidge, Stephen E.; Csontos, Aladar A.
2013-01-25
The Nuclear Regulatory Commission (NRC) established the Program to Assess the Reliability of Emerging Nondestructive Techniques (PARENT) to follow on from the successful Program for the Inspection of Nickel alloy Components (PINC). The goal of the PARENT is to conduct a confirmatory assessment of the reliability of nondestructive evaluation (NDE) techniques for detecting and sizing primary water stress corrosion cracks (PWSCC) and applying the lessons learned from PINC to a series of round-robin tests. These open and blind round-robin tests will comprise a new set of typical pressure boundary components including dissimilar metal welds (DMWs) and bottom-mounted instrumentation penetrations. Openmore » round-robin tests will engage research and industry teams worldwide to investigate and demonstrate the reliability of emerging NDE techniques to detect and size flaws with a wide range of lengths, depths, orientations, and locations. Blind round-robin tests will utilize various testing organizations, whose inspectors and procedures are certified by the standards for the nuclear industry in their respective countries, to investigate the ability of established NDE techniques to detect and size flaws whose characteristics range from relatively easy to very difficult for detection and sizing. Blind and open round-robin testing started in late 2011 and early 2012, respectively. This paper will present the work scope with reports on progress, NDE methods evaluated, and project timeline for PARENT.« less
Deskovitz, Mark A; Weed, Nathan C; McLaughlan, Joseph K; Williams, John E
2016-04-01
The reliability of six Minnesota Multiphasic Personality Inventory-Second edition (MMPI-2) computer-based test interpretation (CBTI) programs was evaluated across a set of 20 commonly appearing MMPI-2 profile codetypes in clinical settings. Evaluation of CBTI reliability comprised examination of (a) interrater reliability, the degree to which raters arrive at similar inferences based on the same CBTI profile and (b) interprogram reliability, the level of agreement across different CBTI systems. Profile inferences drawn by four raters were operationalized using q-sort methodology. Results revealed no significant differences overall with regard to interrater and interprogram reliability. Some specific CBTI/profile combinations (e.g., the CBTI by Automated Assessment Associates on a within normal limits profile) and specific profiles (e.g., the 4/9 profile displayed greater interprogram reliability than the 2/4 profile) were interpreted with variable consensus (α range = .21-.95). In practice, users should consider that certain MMPI-2 profiles are interpreted more or less consensually and that some CBTIs show variable reliability depending on the profile. © The Author(s) 2015.
NASA Astrophysics Data System (ADS)
Gurov, V. V.
2017-01-01
Software tools for educational purposes, such as e-lessons, computer-based testing system, from the point of view of reliability, have a number of features. The main ones among them are the need to ensure a sufficiently high probability of their faultless operation for a specified time, as well as the impossibility of their rapid recovery by the way of replacing it with a similar running program during the classes. The article considers the peculiarities of reliability evaluation of programs in contrast to assessments of hardware reliability. The basic requirements to reliability of software used for carrying out practical and laboratory classes in the form of computer-based training programs are given. The essential requirements applicable to the reliability of software used for conducting the practical and laboratory studies in the form of computer-based teaching programs are also described. The mathematical tool based on Markov chains, which allows to determine the degree of debugging of the training program for use in the educational process by means of applying the graph of the software modules interaction, is presented.
Delphi, Maryam; Lotfi, M-Yones; Moossavi, Abdollah; Bakhshi, Enayatollah; Banimostafa, Maryam
2017-09-01
Previous studies have shown that interaural-time-difference (ITD) training can improve localization ability. Surprisingly little is, however, known about localization training vis-à-vis speech perception in noise based on interaural time difference in the envelope (ITD ENV). We sought to investigate the reliability of an ITD ENV-based training program in speech-in-noise perception among elderly individuals with normal hearing and speech-in-noise disorder. The present interventional study was performed during 2016. Sixteen elderly men between 55 and 65 years of age with the clinical diagnosis of normal hearing up to 2000 Hz and speech-in-noise perception disorder participated in this study. The training localization program was based on changes in ITD ENV. In order to evaluate the reliability of the training program, we performed speech-in-noise tests before the training program, immediately afterward, and then at 2 months' follow-up. The reliability of the training program was analyzed using the Friedman test and the SPSS software. Significant statistical differences were shown in the mean scores of speech-in-noise perception between the 3 time points (P=0.001). The results also indicated no difference in the mean scores of speech-in-noise perception between the 2 time points of immediately after the training program and 2 months' follow-up (P=0.212). The present study showed the reliability of an ITD ENV-based localization training in elderly individuals with speech-in-noise perception disorder.
Reliability and the design process at Honeywell Avionics Division
NASA Technical Reports Server (NTRS)
Bezat, A.
1981-01-01
The division's philosophy for designed-in reliability and a comparison of reliability programs for space, manned military aircraft, and commercial aircraft, are presented. Topics include: the reliability interface with design and production; the concept phase through final proposal; the design, development, test and evaluation phase; the production phase; and the commonality among space, military, and commercial avionics.
MSFC Skylab Orbital Workshop, volume 5
NASA Technical Reports Server (NTRS)
1974-01-01
The various programs involved in the development of the Skylab Orbital Workshop are discussed. The subjects considered include the following: (1) reliability program, (2) system safety program, (3) testing program, (4) engineering program management, (5) mission operations support, and (6) aerospace applications.
NASA Technical Reports Server (NTRS)
Ledoux, F. N.
1973-01-01
A compilation of engineering design tests which were conducted in support of the Energetic Particle Satellite S-3, S-3A, and S-3b programs. The purpose for conducting the tests was to determine the adequacy and reliability of the Energetic Particles Series of satellites designs. The various tests consisted of: (1) moments of inertia, (2) functional reliability, (3) component and structural integrity, (4) initiators and explosives tests, and (5) acceptance tests.
A methodology for producing reliable software, volume 1
NASA Technical Reports Server (NTRS)
Stucki, L. G.; Moranda, P. B.; Foshee, G.; Kirchoff, M.; Omre, R.
1976-01-01
An investigation into the areas having an impact on producing reliable software including automated verification tools, software modeling, testing techniques, structured programming, and management techniques is presented. This final report contains the results of this investigation, analysis of each technique, and the definition of a methodology for producing reliable software.
CARES/LIFE Ceramics Analysis and Reliability Evaluation of Structures Life Prediction Program
NASA Technical Reports Server (NTRS)
Nemeth, Noel N.; Powers, Lynn M.; Janosik, Lesley A.; Gyekenyesi, John P.
2003-01-01
This manual describes the Ceramics Analysis and Reliability Evaluation of Structures Life Prediction (CARES/LIFE) computer program. The program calculates the time-dependent reliability of monolithic ceramic components subjected to thermomechanical and/or proof test loading. CARES/LIFE is an extension of the CARES (Ceramic Analysis and Reliability Evaluation of Structures) computer program. The program uses results from MSC/NASTRAN, ABAQUS, and ANSYS finite element analysis programs to evaluate component reliability due to inherent surface and/or volume type flaws. CARES/LIFE accounts for the phenomenon of subcritical crack growth (SCG) by utilizing the power law, Paris law, or Walker law. The two-parameter Weibull cumulative distribution function is used to characterize the variation in component strength. The effects of multiaxial stresses are modeled by using either the principle of independent action (PIA), the Weibull normal stress averaging method (NSA), or the Batdorf theory. Inert strength and fatigue parameters are estimated from rupture strength data of naturally flawed specimens loaded in static, dynamic, or cyclic fatigue. The probabilistic time-dependent theories used in CARES/LIFE, along with the input and output for CARES/LIFE, are described. Example problems to demonstrate various features of the program are also included.
Reliability and Availability Evaluation Program Manual.
1982-11-01
research and development. The manual’s purpose was to provide a practical method for making reliability measurements, measurements directly related to... Research , Development, Test and Evaluation. RMA Reliability, Maintainability and Availability. R&R Repair and Refurbishment, Repair and Replacement, etc...length. phenomena such as mechanical wear and A number of researchers in the reliability chemical deterioration. Maintenance should field 14-pages 402
Stress and Reliability Analysis of a Metal-Ceramic Dental Crown
NASA Technical Reports Server (NTRS)
Anusavice, Kenneth J; Sokolowski, Todd M.; Hojjatie, Barry; Nemeth, Noel N.
1996-01-01
Interaction of mechanical and thermal stresses with the flaws and microcracks within the ceramic region of metal-ceramic dental crowns can result in catastrophic or delayed failure of these restorations. The objective of this study was to determine the combined influence of induced functional stresses and pre-existing flaws and microcracks on the time-dependent probability of failure of a metal-ceramic molar crown. A three-dimensional finite element model of a porcelain fused-to-metal (PFM) molar crown was developed using the ANSYS finite element program. The crown consisted of a body porcelain, opaque porcelain, and a metal substrate. The model had a 300 Newton load applied perpendicular to one cusp, a load of 30ON applied at 30 degrees from the perpendicular load case, directed toward the center, and a 600 Newton vertical load. Ceramic specimens were subjected to a biaxial flexure test and the load-to-failure of each specimen was measured. The results of the finite element stress analysis and the flexure tests were incorporated in the NASA developed CARES/LIFE program to determine the Weibull and fatigue parameters and time-dependent fracture reliability of the PFM crown. CARES/LIFE calculates the time-dependent reliability of monolithic ceramic components subjected to thermomechanical and/Or proof test loading. This program is an extension of the CARES (Ceramics Analysis and Reliability Evaluation of Structures) computer program.
ERIC Educational Resources Information Center
Mowder, Barbara A.; Shamah, Renee
2011-01-01
This study evaluated the test-retest reliability of two parenting measures: the Parent Behavior Importance Questionnaire-Revised (PBIQ-R) and Parent Behavior Frequency Questionnaire-Revised (PBFQ-R). These self-report parenting behavior assessment measures may be utilized as pre- and post-parent education program measures, with parents as well as…
ERIC Educational Resources Information Center
Bradford, Traliece; Serrano, Elena L.; Cox, Ruby H.; Lambur, Michael
2010-01-01
Objective: To develop and assess reliability and validity of the Nutrition, Food Safety, and Physical Activity Checklist to measure nutrition, food safety, and physical activity practices among adult Expanded Food and Nutrition Education Program (EFNEP) and Food Stamp Nutrition Education program (FSNE) participants. Methods: Test-retest…
General test plan redundant sensor strapdown IMU evaluation program
NASA Technical Reports Server (NTRS)
Hartwell, T.; Irwin, H. A.; Miyatake, Y.; Wedekind, D. E.
1971-01-01
The general test plan for a redundant sensor strapdown inertial measuring unit evaluation program is presented. The inertial unit contains six gyros and three orthogonal accelerometers. The software incorporates failure detection and correction logic and a land vehicle navigation program. The principal objective of the test is a demonstration of the practicability, reliability, and performance of the inertial measuring unit with failure detection and correction in operational environments.
ERIC Educational Resources Information Center
Kara, Filiz; Celikler, Dilek
2015-01-01
For "Matter Changing" unit included in the Secondary School 5th Grade Science Program, it is intended to develop a test conforming the gains described in the program, and that can determine students' achievements. For this purpose, a multiple-choice test of 48 questions is arranged, consisting of 8 questions for each gain included in the…
Automated Portable Test System (APTS) - A performance envelope assessment tool
NASA Technical Reports Server (NTRS)
Kennedy, R. S.; Dunlap, W. P.; Jones, M. B.; Wilkes, R. L.; Bittner, A. C., Jr.
1985-01-01
The reliability and stability of microcomputer-based psychological tests are evaluated. The hardware, test programs, and system control of the Automated Portable Test System, which assesses human performance and subjective status, are described. Subjects were administered 11 pen-and-pencil and microcomputer-based tests for 10 sessions. The data reveal that nine of the 10 tests stabilized by the third administration; inertial correlations were high and consistent. It is noted that the microcomputer-based tests display good psychometric properties in terms of differential stability and reliability.
NASA Technical Reports Server (NTRS)
1974-01-01
System design and performance of the Skylab Airlock Module and Payload Shroud are presented for the communication and caution and warning systems. Crew station and storage, crew trainers, experiments, ground support equipment, and system support activities are also reviewed. Other areas documented include the reliability and safety programs, test philosophy, engineering project management, and mission operations support.
1983-10-05
battle damage. Others are local electrical power and cooling disruptions. Again, a highly critical function is lost if its computer site is destroyed. A...formalized design of the test bed to meet the requirements of the functional description and goals of the program. AMTEC --Z3IT TASKS: 610, 710, 810
A general software reliability process simulation technique
NASA Technical Reports Server (NTRS)
Tausworthe, Robert C.
1991-01-01
The structure and rationale of the generalized software reliability process, together with the design and implementation of a computer program that simulates this process are described. Given assumed parameters of a particular project, the users of this program are able to generate simulated status timelines of work products, numbers of injected anomalies, and the progress of testing, fault isolation, repair, validation, and retest. Such timelines are useful in comparison with actual timeline data, for validating the project input parameters, and for providing data for researchers in reliability prediction modeling.
Paddock, L E; Veloski, J; Chatterton, M L; Gevirtz, F O; Nash, D B
2000-07-01
To develop a reliable and valid questionnaire to measure patient satisfaction with diabetes disease management programs. Questions related to structure, process, and outcomes were categorized into 14 domains defining the essential elements of diabetes disease management. Health professionals confirmed the content validity. Face validity was established by a patient focus group. The questionnaire was mailed to 711 patients with diabetes who participated in a disease management program. To reduce the number of questionnaire items, a principal components analysis was performed using a varimax rotation. The Scree test was used to select significant components. To further assess reliability and validity; Cronbach's alpha and product-moment correlations were calculated for components having > or =3 items with loadings >0.50. The validated 73-item mailed satisfaction survey had a 34.1% response rate. Principal components analysis yielded 13 components with eigenvalues > 1.0. The Scree test proposed a 6-component solution (39 items), which explained 59% of the total variation. Internal consistency reliabilities computed for the first 6 components (alpha = 0.79-0.95) were acceptable. The final questionnaire, the Diabetes Management Evaluation Tool (DMET), was designed to assess patient satisfaction with diabetes disease management programs. Although more extensive testing of the questionnaire is appropriate, preliminary reliability and validity of the DMET has been demonstrated.
Systems design study of the Pioneer Venus spacecraft. Volume 2. Preliminary program development plan
NASA Technical Reports Server (NTRS)
1973-01-01
The preliminary development plan for the Pioneer Venus program is presented. This preliminary plan treats only developmental aspects that would have a significant effect on program cost. These significant development areas were: master program schedule planning; test planning - both unit and system testing for probes/orbiter/ probe bus; ground support equipment; performance assurance; and science integration Various test planning options and test method techniques were evaluated in terms of achieving a low-cost program without degrading mission performance or system reliability. The approaches studied and the methodology of the selected approach are defined.
Technology demonstrator program for Space Station Environmental Control Life Support System
NASA Technical Reports Server (NTRS)
Adams, Alan M.; Platt, Gordon K.; Claunch, William C.; Humphries, William R.
1987-01-01
The main objectives and requirements of the NASA/Marshall Space Flight Center Technology Demonstration Program are discussed. The program consists of a comparative test and a 90-day manned system test to evaluate an Environmental Control and Life Support System (ECLSS). In the comparative test phase, 14 types of subsystems which perform oxygen and water reclamation functions are to be examined in terms of performance maintenance/service requirements, reliability, and safety. The manned chamber testing phase involves a four person crew using a partial ECLSS for 90 days. The schedule for the program and the program hardware requirements are described.
Effectiveness of spacecraft testing programs
NASA Technical Reports Server (NTRS)
Krausz, A.
1980-01-01
The need for testing under simulated mission operational conditions is discussed and the results of such tests are reviewed from the point of view of the user. A brief overview of the usal test sequences for high reliability long life spacecraft is presented and the effectiveness of the testing program is analyzed in terms of the defects which are discovered by such tests. The need for automation, innovative mechanical test procedures, and design for testability is discussed.
Preliminary study of the reliability of imaging charge coupled devices
NASA Technical Reports Server (NTRS)
Beall, J. R.; Borenstein, M. D.; Homan, R. A.; Johnson, D. L.; Wilson, D. D.; Young, V. F.
1978-01-01
Imaging CCDs are capable of low light level response and high signal-to-noise ratios. In space applications they offer the user the ability to achieve extremely high resolution imaging with minimum circuitry in the photo sensor array. This work relates the CCD121H Fairchild device to the fundamentals of CCDs and the representative technologies. Several failure modes are described, construction is analyzed and test results are reported. In addition, the relationship of the device reliability to packaging principles is analyzed and test data presented. Finally, a test program is defined for more general reliability evaluation of CCDs.
Salyers, M P; McHugo, G J; Cook, J A; Razzano, L A; Drake, R E; Mueser, K T
2001-09-01
Reliability of well-known instruments was examined in 202 people with severe mental illness participating in a multisite vocational study. We examined interrater reliability of the Positive and Negative Syndrome Scale (PANSS) and the internal consistency and test-retest reliability of the PANSS, the Rosenberg Self-Esteem Scale, the Medical Outcomes Study Short Form-36 (SF-36), and the Quality of Life Interview. Most scales had good levels of reliability, with intraclass correlation coefficients (ICCs) and coefficient alphas above .70. However, the SF-36 scales were generally less stable over time, particularly Social Functioning (ICC = .55). Test-retest reliability was lower among less educated respondents and among ethnic minorities. We recommend close monitoring of psychometric issues in future multisite studies.
Reliability Evaluation of Concentrator Photovoltaic Modules per IEC Qualification Specifications
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tamizhmani, Govindasamy
2012-12-05
This project is related to the qualification testing of new generation CPV (concentrator photovoltaics) modules at lower testing costs and lower turnaround time. In this project, the first testing program was completed for two CPV manufacturers, the second testing program was completed for two manufacturers at 65% of the actual testing cost and at less than 3 months of testing turnaround time and the third testing program was completed for two manufacturers at 65% of the actual testing cost and at less than 3 months of testing turnaround time. Due to their financial situation and restructuring, Amonix (one of themore » CPV manufacturers) intermittently terminated the test programs.« less
Sonar Transducer Reliability Improvement Program (STRIP).
1981-04-01
CERAMICS. ... .......................... 31 10. STANDARDIZED TEST PROCEDURE ........ .................... ... 35 11. ACCELERATED LIFE TEST...components, and piece-parts that will meet specified requirements in the operational environment during the entire useful life of the transducer. Standards...C.I. Bohmaun F-3 Reliability & Life Prediction TRI R.I. Smith Specification ,F-4 TR-122 FM4 & Improvements NRL-USRD R.W. Timm 1-5 Metal Matrix
Reliability Programs for Nonelectronic Designs. Volume 2
1983-04-01
afforded. Differ- ences between critical and minor failures must be defined in the RFP so that the test need not be stopped for minor failures. However...not be afforded. Specialized test plans must be developed for nonelectronic equipment. First, differences between critical and minor failures must be...determined prior to initiating the test program so that the test need not be stopped for minor failures. Second, although the test must be interrupted
Methodology for Developing a New EFNEP Food and Physical Activity Behaviors Questionnaire.
Murray, Erin K; Auld, Garry; Baker, Susan S; Barale, Karen; Franck, Karen; Khan, Tarana; Palmer-Keenan, Debra; Walsh, Jennifer
2017-10-01
Research methods are described for developing a food and physical activity behaviors questionnaire for the Expanded Food and Nutrition Education Program (EFNEP), a US Department of Agriculture nutrition education program serving low-income families. Mixed-methods observational study. The questionnaire will include 5 domains: (1) diet quality, (2) physical activity, (3) food safety, (4) food security, and (5) food resource management. A 5-stage process will be used to assess the questionnaire's test-retest reliability and content, face, and construct validity. Research teams across the US will coordinate questionnaire development and testing nationally. Convenience samples of low-income EFNEP, or EFNEP-eligible, adult participants across the US. A 5-stage process: (1) prioritize domain concepts to evaluate (2) question generation and content analysis panel, (3) question pretesting using cognitive interviews, (4) test-retest reliability assessment, and (5) construct validity testing. A nationally tested valid and reliable food and physical activity behaviors questionnaire for low-income adults to evaluate EFNEP's effectiveness. Cognitive interviews will be summarized to identify themes and dominant trends. Paired t tests (P ≤ .05) and Spearman and intra-class correlation coefficients (r > .5) will be conducted to assess reliability. Construct validity will be assessed using Wilcoxon t test (P ≤ .05), Spearman correlations, and Bland-Altman plots. Copyright © 2017 Society for Nutrition Education and Behavior. Published by Elsevier Inc. All rights reserved.
Measuring the Process and Quality of Informed Consent for Clinical Research: Development and Testing
Cohn, Elizabeth Gross; Jia, Haomiao; Smith, Winifred Chapman; Erwin, Katherine; Larson, Elaine L.
2013-01-01
Purpose/Objectives To develop and assess the reliability and validity of an observational instrument, the Process and Quality of Informed Consent (P-QIC). Design A pilot study of the psychometrics of a tool designed to measure the quality and process of the informed consent encounter in clinical research. The study used professionally filmed, simulated consent encounters designed to vary in process and quality. Setting A major urban teaching hospital in the northeastern region of the United States. Sample 63 students enrolled in health-related programs participated in psychometric testing, 16 students participated in test-retest reliability, and 5 investigator-participant dyads were observed for the actual consent encounters. Methods For reliability and validity testing, students watched and rated videotaped simulations of four consent encounters intentionally varied in process and content and rated them with the proposed instrument. Test-retest reliability was established by raters watching the videotaped simulations twice. Inter-rater reliability was demonstrated by two simultaneous but independent raters observing an actual consent encounter. Main Research Variables The essential elements of information and communication for informed consent. Findings The initial testing of the P-QIC demonstrated reliable and valid psychometric properties in both the simulated standardized consent encounters and actual consent encounters in the hospital setting. Conclusions The P-QIC is an easy-to-use observational tool that provides a quick assessment of the areas of strength and areas that need improvement in a consent encounter. It can be used in the initial trainings of new investigators or consent administrators and in ongoing programs of improvement for informed consent. Implications for Nursing The development of a validated observational instrument will allow investigators to assess the consent process more accurately and evaluate strategies designed to improve it. PMID:21708532
Tracer-Test Planning Using the Efficient Hydrologic Tracer-Test Design (Ehtd) Program (2005)
Hydrological tracer testing is the most reliable diagnostic technique available for establishing flow trajectories and hydrologic connections and for determining basic hydraulic and geometric parameters necessary for establishing operative solute-transport processes. Tracer-test ...
Tracer-Test Planning Using the Efficient Hydrologic Tracer-Test Design (Ehtd) Program (2003)
Hydrological tracer testing is the most reliable diagnostic technique available for establishing flow trajectories and hydrologic connections and for determining basic hydraulic and geometric parameters necessary for establishing operative solute-transport processes. Tracer-test ...
Gilkison, C R; Fenton, M V; Lester, J W
1992-05-01
This study was designed to establish the reliability of a health history questionnaire used as a screening tool for incoming university students. The authors used a test-retest design, with a test interval of 6 months, on a sample of medical and nursing students. The analysis focused on overall reliability of the questionnaire and reproducibility of specific items, based on question format. Questionnaire items of specific interest were those with dichotomous yes/no response options versus open-ended format questions, those using the words frequently or recently, or those that asked multiple questions. Demographic characteristics of the subjects were considered in the evaluation of reliability. Overall reliability of the questionnaire (93.6%) was above the anticipated level of 90%, and subject sex or program of study did not show any significant differences in reproducibility of responses. Although wording of questions did not affect item reliability, dichotomous format questions demonstrated a higher degree of reliability (96.4%) than the overall reliability of the questionnaire. Recommendations for enhancing the reliability of the questionnaire are based on item analysis and information gathered from interviews with subjects.
Pilot testing of SHRP 2 reliability data and analytical products: Southern California.
DOT National Transportation Integrated Search
2015-01-01
The second Strategic Highway Research Program (SHRP 2) has been investigating the critical subject of travel time reliability for several years. As part of this research, SHRP 2 supported multiple efforts to develop products to evaluate travel time r...
Characterizing reliability in a product/process design-assurance program
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kerscher, W.J. III; Booker, J.M.; Bement, T.R.
1997-10-01
Over the years many advancing techniques in the area of reliability engineering have surfaced in the military sphere of influence, and one of these techniques is Reliability Growth Testing (RGT). Private industry has reviewed RGT as part of the solution to their reliability concerns, but many practical considerations have slowed its implementation. It`s objective is to demonstrate the reliability requirement of a new product with a specified confidence. This paper speaks directly to that objective but discusses a somewhat different approach to achieving it. Rather than conducting testing as a continuum and developing statistical confidence bands around the results, thismore » Bayesian updating approach starts with a reliability estimate characterized by large uncertainty and then proceeds to reduce the uncertainty by folding in fresh information in a Bayesian framework.« less
TIMESERIESSTREAMING.VI: LabVIEW program for reliable data streaming of large analog time series
NASA Astrophysics Data System (ADS)
Czerwinski, Fabian; Oddershede, Lene B.
2011-02-01
With modern data acquisition devices that work fast and very precise, scientists often face the task of dealing with huge amounts of data. These need to be rapidly processed and stored onto a hard disk. We present a LabVIEW program which reliably streams analog time series of MHz sampling. Its run time has virtually no limitation. We explicitly show how to use the program to extract time series from two experiments: For a photodiode detection system that tracks the position of an optically trapped particle and for a measurement of ionic current through a glass capillary. The program is easy to use and versatile as the input can be any type of analog signal. Also, the data streaming software is simple, highly reliable, and can be easily customized to include, e.g., real-time power spectral analysis and Allan variance noise quantification. Program summaryProgram title: TimeSeriesStreaming.VI Catalogue identifier: AEHT_v1_0 Program summary URL:http://cpc.cs.qub.ac.uk/summaries/AEHT_v1_0.html Program obtainable from: CPC Program Library, Queen's University, Belfast, N. Ireland Licensing provisions: Standard CPC licence, http://cpc.cs.qub.ac.uk/licence/licence.html No. of lines in distributed program, including test data, etc.: 250 No. of bytes in distributed program, including test data, etc.: 63 259 Distribution format: tar.gz Programming language: LabVIEW ( http://www.ni.com/labview/) Computer: Any machine running LabVIEW 8.6 or higher Operating system: Windows XP and Windows 7 RAM: 60-360 Mbyte Classification: 3 Nature of problem: For numerous scientific and engineering applications, it is highly desirable to have an efficient, reliable, and flexible program to perform data streaming of time series sampled with high frequencies and possibly for long time intervals. This type of data acquisition often produces very large amounts of data not easily streamed onto a computer hard disk using standard methods. Solution method: This LabVIEW program is developed to directly stream any kind of time series onto a hard disk. Due to optimized timing and usage of computational resources, such as multicores and protocols for memory usage, this program provides extremely reliable data acquisition. In particular, the program is optimized to deal with large amounts of data, e.g., taken with high sampling frequencies and over long time intervals. The program can be easily customized for time series analyses. Restrictions: Only tested in Windows-operating LabVIEW environments, must use TDMS format, acquisition cards must be LabVIEW compatible, driver DAQmx installed. Running time: As desirable: microseconds to hours
DOT National Transportation Integrated Search
2014-01-01
The objective of this project was to develop system designs for programs to monitor travel time reliability and to prepare a guidebook that practitioners and others can use to design, build, operate, and maintain such systems. Generally, such travel ...
Pilot testing of SHRP 2 reliability data and analytical products: Minnesota. [supporting datasets
DOT National Transportation Integrated Search
2014-01-01
The objective of this project was to develop system designs for programs to monitor travel time reliability and to prepare a guidebook that practitioners and others can use to design, build, operate, and maintain such systems. Generally, such travel ...
Using Facility Condition Assessments to Identify Actions Related to Infrastructure
NASA Technical Reports Server (NTRS)
Rubert, Kennedy F.
2010-01-01
To support cost effective, quality research it is essential that laboratory and testing facilities are maintained in a continuous and reliable state of availability at all times. NASA Langley Research Center (LaRC) and its maintenance contractor, Jacobs Technology, Inc. Research Operations, Maintenance, and Engineering (ROME) group, are in the process of implementing a combined Facility Condition Assessment (FCA) and Reliability Centered Maintenance (RCM) program to improve asset management and overall reliability of testing equipment in facilities such as wind tunnels. Specific areas are being identified for improvement, the deferred maintenance cost is being estimated, and priority is being assigned against facilities where conditions have been allowed to deteriorate. This assessment serves to assist in determining where to commit available funds on the Center. RCM methodologies are being reviewed and enhanced to assure that appropriate preventive, predictive, and facilities/equipment acceptance techniques are incorporated to prolong lifecycle availability and assure reliability at minimum cost. The results from the program have been favorable, better enabling LaRC to manage assets prudently.
van der Laan, Tallie M J; Postema, Sietke G; Reneman, Michiel F; Bongers, Raoul M; van der Sluis, Corry K
2018-02-10
Reliability study. Quantifying compensatory movements during work-related tasks may help to prevent musculoskeletal complaints in individuals with upper limb absence. (1) To develop a qualitative scoring system for rating compensatory shoulder and trunk movements in upper limb prosthesis wearers during the performance of functional capacity evaluation tests adjusted for use by 1-handed individuals (functional capacity evaluation-one handed [FCE-OH]); (2) to examine the interrater and intrarater reliability of the scoring system; and (3) to assess its feasibility. Movement patterns of 12 videotaped upper limb prosthesis wearers and 20 controls were analyzed. Compensatory movements were defined for each FCE-OH test, and a scoring system was developed, pilot tested, and adjusted. During reliability testing, 18 raters (12 FCE experts and 6 physiotherapists/gait analysts) scored videotapes of upper limb prosthesis wearers performing 4 FCE-OH tests 2 times (2 weeks apart). Agreement was expressed in % and kappa value. Feasibility (focus area's "acceptability", "demand," and "implementation") was determined by using a questionnaire. After 2 rounds of pilot testing and adjusting, reliability of a third version was tested. The interrater reliability for the first and second rating sessions were к = 0.54 (confidence interval [CI]: 0.52-0.57) and к = 0.64 (CI: 0.61-0.66), respectively. The intrarater reliability was к = 0.77 (CI: 0.72-0.82). The feasibility was good but could be improved by a training program. It seems possible to identify compensatory movements in upper limb prosthesis wearers during the performance of FCE-OH tests reliably by observation using the developed observational scoring system. Interrater reliability was satisfactory in most instances; intrarater reliability was good. Feasibility was established. Copyright © 2018 Hanley & Belfus. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Strunz, Richard; Herrmann, Jeffrey W.
2011-12-01
The hot fire test strategy for liquid rocket engines has always been a concern of space industry and agency alike because no recognized standard exists. Previous hot fire test plans focused on the verification of performance requirements but did not explicitly include reliability as a dimensioning variable. The stakeholders are, however, concerned about a hot fire test strategy that balances reliability, schedule, and affordability. A multiple criteria test planning model is presented that provides a framework to optimize the hot fire test strategy with respect to stakeholder concerns. The Staged Combustion Rocket Engine Demonstrator, a program of the European Space Agency, is used as example to provide the quantitative answer to the claim that a reduced thrust scale demonstrator is cost beneficial for a subsequent flight engine development. Scalability aspects of major subsystems are considered in the prior information definition inside the Bayesian framework. The model is also applied to assess the impact of an increase of the demonstrated reliability level on schedule and affordability.
NASA Astrophysics Data System (ADS)
McPhee, J.; William, Y. W.
2005-12-01
This work presents a methodology for pumping test design based on the reliability requirements of a groundwater model. Reliability requirements take into consideration the application of the model results in groundwater management, expressed in this case as a multiobjective management model. The pumping test design is formulated as a mixed-integer nonlinear programming (MINLP) problem and solved using a combination of genetic algorithm (GA) and gradient-based optimization. Bayesian decision theory provides a formal framework for assessing the influence of parameter uncertainty over the reliability of the proposed pumping test. The proposed methodology is useful for selecting a robust design that will outperform all other candidate designs under most potential 'true' states of the system
NASA Technical Reports Server (NTRS)
Ferlita, F.
1989-01-01
The Advanced Launch Systems (ALS) Advanced Development Oxidizer Turbopump Program has designed, fabricated and demonstrated a low cost, highly reliable oxidizer turbopump for the Space Transportation Engine that minimizes the recurring cost for the ALS engines. Pratt and Whitney's (P and W's) plan for integrating the analyses, testing, fabrication, and other program efforts is addressed. This plan offers a comprehensive description of the total effort required to design, fabricate, and test the ALS oxidizer turbopump. The proposed ALS oxidizer turbopump reduces turbopump costs over current designs by taking advantage of design simplicity and state-of-the-art materials and producibility features without compromising system reliability. This is accomplished by selecting turbopump operating conditions that are within known successful operating regions and by using proven manufacturing techniques.
Assessing reliability and validity measures in managed care studies.
Montoya, Isaac D
2003-01-01
To review the reliability and validity literature and develop an understanding of these concepts as applied to managed care studies. Reliability is a test of how well an instrument measures the same input at varying times and under varying conditions. Validity is a test of how accurately an instrument measures what one believes is being measured. A review of reliability and validity instructional material was conducted. Studies of managed care practices and programs abound. However, many of these studies utilize measurement instruments that were developed for other purposes or for a population other than the one being sampled. In other cases, instruments have been developed without any testing of the instrument's performance. The lack of reliability and validity information may limit the value of these studies. This is particularly true when data are collected for one purpose and used for another. The usefulness of certain studies without reliability and validity measures is questionable, especially in cases where the literature contradicts itself
Failure mode analysis to predict product reliability.
NASA Technical Reports Server (NTRS)
Zemanick, P. P.
1972-01-01
The failure mode analysis (FMA) is described as a design tool to predict and improve product reliability. The objectives of the failure mode analysis are presented as they influence component design, configuration selection, the product test program, the quality assurance plan, and engineering analysis priorities. The detailed mechanics of performing a failure mode analysis are discussed, including one suggested format. Some practical difficulties of implementation are indicated, drawn from experience with preparing FMAs on the nuclear rocket engine program.
Reliability Programs for Nonelectronic Designs. Volume 1
1983-04-01
to the system or component levels or to both and then Its degree of effectiveness. DOCUMENT ID TITLE/SUBJECT APPLICATION EFFECTIVENESS Sys ./Comp/Both...ID TITLE/SUBJECT APPLICATION EFFECTIVENESS ’ Sys ./Comp/Both Exc./Good/Poor MIL-STD-781B Reliability Tests Exponen- 1 1 1 1 Ii II tial Distribution MIL...DOCUMENT ID TITLE/SUBJECT APPLICATION EFFECTIVENESS Sys ./Comp/Both Exc./Good/Poor MIL-STD-1535A Supplier Quality Assurance I 1 I1 I 1 1 I Program
Structural Optimization for Reliability Using Nonlinear Goal Programming
NASA Technical Reports Server (NTRS)
El-Sayed, Mohamed E.
1999-01-01
This report details the development of a reliability based multi-objective design tool for solving structural optimization problems. Based on two different optimization techniques, namely sequential unconstrained minimization and nonlinear goal programming, the developed design method has the capability to take into account the effects of variability on the proposed design through a user specified reliability design criterion. In its sequential unconstrained minimization mode, the developed design tool uses a composite objective function, in conjunction with weight ordered design objectives, in order to take into account conflicting and multiple design criteria. Multiple design criteria of interest including structural weight, load induced stress and deflection, and mechanical reliability. The nonlinear goal programming mode, on the other hand, provides for a design method that eliminates the difficulty of having to define an objective function and constraints, while at the same time has the capability of handling rank ordered design objectives or goals. For simulation purposes the design of a pressure vessel cover plate was undertaken as a test bed for the newly developed design tool. The formulation of this structural optimization problem into sequential unconstrained minimization and goal programming form is presented. The resulting optimization problem was solved using: (i) the linear extended interior penalty function method algorithm; and (ii) Powell's conjugate directions method. Both single and multi-objective numerical test cases are included demonstrating the design tool's capabilities as it applies to this design problem.
A flight test of laminar flow control leading-edge systems
NASA Technical Reports Server (NTRS)
Fischer, M. C.; Wright, A. S., Jr.; Wagner, R. D.
1983-01-01
NASA's program for development of a laminar flow technology base for application to commercial transports has made significant progress since its inception in 1976. Current efforts are focused on development of practical reliable systems for the leading-edge region where the most difficult problems in applying laminar flow exist. Practical solutions to these problems will remove many concerns about the ultimate practicality of laminar flow. To address these issues, two contractors performed studies, conducted development tests, and designed and fabricated fully functional leading-edge test articles for installation on the NASA JetStar aircraft. Systems evaluation and performance testing will be conducted to thoroughly evaluate all system capabilities and characteristics. A simulated airline service flight test program will be performed to obtain the operational sensitivity, maintenance, and reliability data needed to establish that practical solutions exist for the difficult leading-edge area of a future commercial transport employing laminar flow control.
Abstract:The National STEPP Program seeks to improve water quality by accelerating the effective implementation and adoption of innovative stormwater management technologies. Itwill attempt to accomplish this by establishing practices through highly reliable, and cost-effective S...
76 FR 47178 - Energy Efficiency Program: Test Procedure for Lighting Systems (Luminaires)
Federal Register 2010, 2011, 2012, 2013, 2014
2011-08-04
...: Test Procedure for Lighting Systems (Luminaires) AGENCY: Office of Energy Efficiency and Renewable... (``DOE'' or the ``Department'') is currently evaluating energy efficiency test procedures for luminaires... products. DOE recognizes that well-designed test procedures are important to produce reliable, repeatable...
Best Practices for Reliable and Robust Spacecraft Structures
NASA Technical Reports Server (NTRS)
Raju, Ivatury S.; Murthy, P. L. N.; Patel, Naresh R.; Bonacuse, Peter J.; Elliott, Kenny B.; Gordon, S. A.; Gyekenyesi, J. P.; Daso, E. O.; Aggarwal, P.; Tillman, R. F.
2007-01-01
A study was undertaken to capture the best practices for the development of reliable and robust spacecraft structures for NASA s next generation cargo and crewed launch vehicles. In this study, the NASA heritage programs such as Mercury, Gemini, Apollo, and the Space Shuttle program were examined. A series of lessons learned during the NASA and DoD heritage programs are captured. The processes that "make the right structural system" are examined along with the processes to "make the structural system right". The impact of technology advancements in materials and analysis and testing methods on reliability and robustness of spacecraft structures is studied. The best practices and lessons learned are extracted from these studies. Since the first human space flight, the best practices for reliable and robust spacecraft structures appear to be well established, understood, and articulated by each generation of designers and engineers. However, these best practices apparently have not always been followed. When the best practices are ignored or short cuts are taken, risks accumulate, and reliability suffers. Thus program managers need to be vigilant of circumstances and situations that tend to violate best practices. Adherence to the best practices may help develop spacecraft systems with high reliability and robustness against certain anomalies and unforeseen events.
Accelerated stress testing of terrestrial solar cells
NASA Technical Reports Server (NTRS)
Prince, J. L.; Lathrop, J. W.
1979-01-01
A program to investigate the reliability characteristics of unencapsulated low-cost terrestrial solar cells using accelerated stress testing is described. Reliability (or parametric degradation) factors appropriate to the cell technologies and use conditions were studied and a series of accelerated stress tests was synthesized. An electrical measurement procedure and a data analysis and management system was derived, and stress test fixturing and material flow procedures were set up after consideration was given to the number of cells to be stress tested and measured and the nature of the information to be obtained from the process. Selected results and conclusions are presented.
NDE Techniques Used in PARENT Open Round Robin Testing
DOE Office of Scientific and Technical Information (OSTI.GOV)
Meyer, Ryan M.
2014-11-05
This is a draft technical letter report for NRC client describing the NDE techniques used in the open testing portion of the Program to Assess the Reliability of Emerging Nondestructive Techniques (PARENT).
Toward lean satellites reliability improvement using HORYU-IV project as case study
NASA Astrophysics Data System (ADS)
Faure, Pauline; Tanaka, Atomu; Cho, Mengu
2017-04-01
Lean satellite programs are programs in which the satellite development philosophy is driven by fast delivery and low cost. Though this concept offers the possibility to develop and fly risky missions without jeopardizing a space program, most of these satellites suffer infant mortality and fail to achieve their mission minimum success. Lean satellites with high infant mortality rate indicate that testing prior to launch is insufficient. In this study, the authors monitored failures occurring during the development of the lean satellite HORYU-IV to identify the evolution of the cumulative number of failures against cumulative testing time. Moreover, the sub-systems driving the failures depending on the different development phases were identified. The results showed that half to 2/3 of the failures are discovered during the early stage of testing. Moreover, when the mean time before failure was calculated, it appeared that for any development phase considered, a new failure appears on average every 20 h of testing. Simulations were also performed and it showed that for an initial testing time of 50 h, reliability after 1 month launch can be improved by nearly 6 times as compared to an initial testing time of 20 h. Through this work, the authors aim at providing a qualitative reference for lean satellites developers to better help them manage resources to develop lean satellites following a fast delivery and low cost philosophy while ensuring sufficient reliability to achieve mission minimum success.
Software reliability perspectives
NASA Technical Reports Server (NTRS)
Wilson, Larry; Shen, Wenhui
1987-01-01
Software which is used in life critical functions must be known to be highly reliable before installation. This requires a strong testing program to estimate the reliability, since neither formal methods, software engineering nor fault tolerant methods can guarantee perfection. Prior to the final testing software goes through a debugging period and many models have been developed to try to estimate reliability from the debugging data. However, the existing models are poorly validated and often give poor performance. This paper emphasizes the fact that part of their failures can be attributed to the random nature of the debugging data given to these models as input, and it poses the problem of correcting this defect as an area of future research.
Monte Carlo Approach for Reliability Estimations in Generalizability Studies.
ERIC Educational Resources Information Center
Dimitrov, Dimiter M.
A Monte Carlo approach is proposed, using the Statistical Analysis System (SAS) programming language, for estimating reliability coefficients in generalizability theory studies. Test scores are generated by a probabilistic model that considers the probability for a person with a given ability score to answer an item with a given difficulty…
Reliability in fiber optic cable harness manufacturing
NASA Astrophysics Data System (ADS)
McCoy, Bruce M.
Key aspects of manufacturing cable harnesses for aircraft and spacecraft that incorporate optical fiber/cables along with traditional wiring are discussed. Issues regarding feasibility of automation of assembly processes, manual assembly, testing, installation, quality assurance, reliability and maintainability are addressed. Training procedures, formal training programs, and their results are reviewed.
Apollo lunar orbital sciences program alpha and X-ray spectrometers
NASA Technical Reports Server (NTRS)
1972-01-01
The development of the alpha and X-ray spectrometers which were used on the Apollo 15 and 16 flights is discussed. Specific subjects presented are: (1) lunar program management, (2) scientific and technical approach, (3) major test programs, (4) reliability, quality assurance, and safety, and (5) subcontract management.
Translation and validation of the Malay version of the Stroke Knowledge Test.
Sowtali, Siti Noorkhairina; Yusoff, Dariah Mohd; Harith, Sakinah; Mohamed, Monniaty
2016-04-01
To date, there is a lack of published studies on assessment tools to evaluate the effectiveness of stroke education programs. This study developed and validated the Malay language version of the Stroke Knowledge Test research instrument. This study involved translation, validity, and reliability phases. The instrument underwent backward and forward translation of the English version into the Malay language. Nine experts reviewed the content for consistency, clarity, difficulty, and suitability for inclusion. Perceived usefulness and utilization were obtained from experts' opinions. Later, face validity assessment was conducted with 10 stroke patients to determine appropriateness of sentences and grammar used. A pilot study was conducted with 41 stroke patients to determine the item analysis and reliability of the translated instrument using the Kuder Richardson 20 or Cronbach's alpha. The final Malay version Stroke Knowledge Test included 20 items with good content coverage, acceptable item properties, and positive expert review ratings. Psychometric investigations suggest that Malay version Stroke Knowledge Test had moderate reliability with Kuder Richardson 20 or Cronbach's alpha of 0.58. Improvement is required for Stroke Knowledge Test items with unacceptable difficulty indices. Overall, the average rating of perceived usefulness and perceived utility of the instruments were both 72.7%, suggesting that reviewers were likely to use the instruments in their facilities. Malay version Stroke Knowledge Test was a valid and reliable tool to assess educational needs and to evaluate stroke knowledge among participants of group-based stroke education programs in Malaysia.
Light aircraft crash safety program
NASA Technical Reports Server (NTRS)
Thomson, R. G.; Hayduk, R. J.
1974-01-01
NASA is embarked upon research and development tasks aimed at providing the general aviation industry with a reliable crashworthy airframe design technology. The goals of the NASA program are: reliable analytical techniques for predicting the nonlinear behavior of structures; significant design improvements of airframes; and simulated full-scale crash test data. The analytical tools will include both simplified procedures for estimating energy absorption characteristics and more complex computer programs for analysis of general airframe structures under crash loading conditions. The analytical techniques being developed both in-house and under contract are described, and a comparison of some analytical predictions with experimental results is shown.
NASA Technical Reports Server (NTRS)
Simmons, D. B.
1975-01-01
The DOMONIC system has been modified to run on the Univac 1108 and the CDC 6600 as well as the IBM 370 computer system. The DOMONIC monitor system has been implemented to gather data which can be used to optimize the DOMONIC system and to predict the reliability of software developed using DOMONIC. The areas of quality metrics, error characterization, program complexity, program testing, validation and verification are analyzed. A software reliability model for estimating program completion levels and one on which to base system acceptance have been developed. The DAVE system which performs flow analysis and error detection has been converted from the University of Colorado CDC 6400/6600 computer to the IBM 360/370 computer system for use with the DOMONIC system.
Development of the Systems Thinking Scale for Adolescent Behavior Change.
Moore, Shirley M; Komton, Vilailert; Adegbite-Adeniyi, Clara; Dolansky, Mary A; Hardin, Heather K; Borawski, Elaine A
2018-03-01
This report describes the development and psychometric testing of the Systems Thinking Scale for Adolescent Behavior Change (STS-AB). Following item development, initial assessments of understandability and stability of the STS-AB were conducted in a sample of nine adolescents enrolled in a weight management program. Exploratory factor analysis of the 16-item STS-AB and internal consistency assessments were then done with 359 adolescents enrolled in a weight management program. Test-retest reliability of the STS-AB was .71, p = .03; internal consistency reliability was .87. Factor analysis of the 16-item STS-AB indicated a one-factor solution with good factor loadings, ranging from .40 to .67. Evidence of construct validity was supported by significant correlations with established measures of variables associated with health behavior change. We provide beginning evidence of the reliability and validity of the STS-AB to measure systems thinking for health behavior change in young adolescents.
Detection of faults and software reliability analysis
NASA Technical Reports Server (NTRS)
Knight, John C.
1987-01-01
Multi-version or N-version programming is proposed as a method of providing fault tolerance in software. The approach requires the separate, independent preparation of multiple versions of a piece of software for some application. These versions are executed in parallel in the application environment; each receives identical inputs and each produces its version of the required outputs. The outputs are collected by a voter and, in principle, they should all be the same. In practice there may be some disagreement. If this occurs, the results of the majority are taken to be the correct output, and that is the output used by the system. A total of 27 programs were produced. Each of these programs was then subjected to one million randomly-generated test cases. The experiment yielded a number of programs containing faults that are useful for general studies of software reliability as well as studies of N-version programming. Fault tolerance through data diversity and analytic models of comparison testing are discussed.
A Theory-Grounded Measure of Adolescents’ Response to a Media Literacy Intervention
Greene, Kathryn; Yanovitzky, Itzhak; Carpenter, Amanda; Banerjee, Smita C.; Magsamen-Conrad, Kate; Hecht, Michael L.; Elek, Elvira
2016-01-01
Media literacy interventions offer promising avenues for the prevention of risky health behaviors among children and adolescents, but current literature remains largely equivocal about their efficacy. The primary objective of this study was to develop and test theoretically-grounded measures of audiences’ degree of engagement with the content of media literacy programs based on the recognition that engagement (and not participation per se) can better explain and predict individual variations in the effects of these programs. We tested the validity and reliability of a measure of engagement with two different samples of 10th grade high school students who participated in a pilot and actual test of a brief media literacy curriculum. Four message evaluation factors (involvement, perceived novelty, critical thinking, personal reflection) emerged and demonstrate acceptable reliability. PMID:28042522
Study of solid rocket motors for a space shuttle booster. Volume 3: Program acquisition planning
NASA Technical Reports Server (NTRS)
Vonderesch, A. H.
1972-01-01
Plans for conducting Phase C/D for a solid rocket motor booster vehicle are presented. Methods for conducting this program with details of scheduling, testing, and program management and control are included. The requirements of the space shuttle program to deliver a minimum cost/maximum reliability booster vehicle are examined.
Descriptive Model of Generic WAMS
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hauer, John F.; DeSteese, John G.
The Department of Energy’s (DOE) Transmission Reliability Program is supporting the research, deployment, and demonstration of various wide area measurement system (WAMS) technologies to enhance the reliability of the Nation’s electrical power grid. Pacific Northwest National Laboratory (PNNL) was tasked by the DOE National SCADA Test Bed Program to conduct a study of WAMS security. This report represents achievement of the milestone to develop a generic WAMS model description that will provide a basis for the security analysis planned in the next phase of this study.
A Reliability Improvement Program Planning Report for the SNAP 10A Space Nuclear Power Unit
DOE Office of Scientific and Technical Information (OSTI.GOV)
Coombs, M. G.; Smith, C. K.; Wilson, L. A.
1961-03-14
The estimated achieved reliability of SNAP 10A space nuclear power units will be relatively low at the timeof the first SNAPSHOT flight test in April 1963 and the existing R&D program does not provide a significant reliabiity growth thereafter. The total costs of an 8-satellite network using SNAP 10A units over a 5-year period has been approximated for the case where the total cost of a single satellite launched is 8 million dollars.
NASA Astrophysics Data System (ADS)
Meyer, Ryan M.; Komura, Ichiro; Kim, Kyung-cho; Zetterwall, Tommy; Cumblidge, Stephen E.; Prokofiev, Iouri
2016-02-01
In February 2012, the U.S. Nuclear Regulatory Commission (NRC) executed agreements with VTT Technical Research Centre of Finland, Nuclear Regulatory Authority of Japan (NRA, former JNES), Korea Institute of Nuclear Safety (KINS), Swedish Radiation Safety Authority (SSM), and Swiss Federal Nuclear Safety Inspectorate (ENSI) to establish the Program to Assess the Reliability of Emerging Nondestructive Techniques (PARENT). The goal of PARENT is to investigate the effectiveness of current emerging and perspective novel nondestructive examination procedures and techniques to find flaws in nickel-alloy welds and base materials. This is done by conducting a series of open and blind international round-robin tests on a set of large-bore dissimilar metal welds (LBDMW), small-bore dissimilar metal welds (SBDMW), and bottom-mounted instrumentation (BMI) penetration weld test blocks. The purpose of blind testing is to study the reliability of more established techniques and included only qualified teams and procedures. The purpose of open testing is aimed at a more basic capability assessment of emerging and novel technologies. The range of techniques applied in open testing varied with respect to maturity and performance uncertainty and were applied to a variety of simulated flaws. This paper will include a brief overview of the PARENT blind and open testing techniques and test blocks and present some of the blind testing results.
Long life reliability thermal control systems study
NASA Technical Reports Server (NTRS)
Scollon, T. R., Jr.; Killen, R. E.
1972-01-01
The results of a program undertaken to conceptually design and evaluate a passive, high reliability, long life thermal control system for space station application are presented. The program consisted of four steps: (1) investigate and select potential thermal system elements; (2) conceive, evaluate and select a thermal control system using these elements; (3) conduct a verification test of a prototype segment of the selected system; and (4) evaluate the utilization of waste heat from the power supply. The result of this project is a conceptual thermal control system design which employs heat pipes as primary components, both for heat transport and temperature control. The system, its evaluation, and the test results are described.
NASA Technical Reports Server (NTRS)
DiBlasi, Angelo G.
1992-01-01
A preliminary development plan for an integrated propulsion module (IPM) is described. The IPM, similar to the Space Transportation Main engine (STME) engine, is applicable to the Advanced Launch System (ALS) baseline vehicle. The same STME development program ground rules and time schedule were assumed for the IPM. However, the unique advantages of testing an integrated engine element, in terms of reduced number of hardware and number of system and reliability tests, compared to single standalone engine and MPTA, are highlighted. The potential ability of the IPM to meet the ALS program goals for robustness, operability and reliability is emphasized.
Reliability analysis and utilization of PEMs in space application
NASA Astrophysics Data System (ADS)
Jiang, Xiujie; Wang, Zhihua; Sun, Huixian; Chen, Xiaomin; Zhao, Tianlin; Yu, Guanghua; Zhou, Changyi
2009-11-01
More and more plastic encapsulated microcircuits (PEMs) are used in space missions to achieve high performance. Since PEMs are designed for use in terrestrial operating conditions, the successful usage of PEMs in space harsh environment is closely related to reliability issues, which should be considered firstly. However, there is no ready-made methodology for PEMs in space applications. This paper discusses the reliability for the usage of PEMs in space. This reliability analysis can be divided into five categories: radiation test, radiation hardness, screening test, reliability calculation and reliability assessment. One case study is also presented to illuminate the details of the process, in which a PEM part is used in a joint space program Double-Star Project between the European Space Agency (ESA) and China. The influence of environmental constrains including radiation, humidity, temperature and mechanics on the PEM part has been considered. Both Double-Star Project satellites are still running well in space now.
Hanson, Lisa C; Taylor, Nicholas F; McBurney, Helen
2016-09-01
To determine the retest reliability of the 10m incremental shuttle walk test (ISWT) in a mixed cardiac rehabilitation population. Participants completed two 10m ISWTs in a single session in a repeated measures study. Ten participants completed a third 10m ISWT as part of a pilot study. Hospital physiotherapy department. 62 adults aged a mean of 68 years (SD 10) referred to a cardiac rehabilitation program. Retest reliability of the 10m ISWT expressed as relative reliability and measurement error. Relative reliability was expressed in a ratio in the form of an intraclass correlation coefficient (ICC) and measurement error in the form of the standard error of measurement (SEM) and 95% confidence intervals for the group and individual. There was a high level of relative reliability over the two walks with an ICC of .99. The SEMagreement was 17m, and a change of at least 23m for the group and 54m for the individual would be required to be 95% confident of exceeding measurement error. The 10m ISWT demonstrated good retest reliability and is sufficiently reliable to be applied in practice in this population without the use of a practice test. Copyright © 2015 Chartered Society of Physiotherapy. Published by Elsevier Ltd. All rights reserved.
33 CFR 154.2180 - Alternative testing program-Generally.
Code of Federal Regulations, 2014 CFR
2014-07-01
... Control Systems Alternative Analyzer and Pressure Sensor Reliability Testing § 154.2180 Alternative... and pressure sensor safety testing requirements provided by 33 CFR 154.2150(c) and 33 CFR 154.2250(c... 33 CFR 154.2181. (d) All pressure sensors/switches used in a VCS must be tested for safety system...
An experiment in software reliability
NASA Technical Reports Server (NTRS)
Dunham, J. R.; Pierce, J. L.
1986-01-01
The results of a software reliability experiment conducted in a controlled laboratory setting are reported. The experiment was undertaken to gather data on software failures and is one in a series of experiments being pursued by the Fault Tolerant Systems Branch of NASA Langley Research Center to find a means of credibly performing reliability evaluations of flight control software. The experiment tests a small sample of implementations of radar tracking software having ultra-reliability requirements and uses n-version programming for error detection, and repetitive run modeling for failure and fault rate estimation. The experiment results agree with those of Nagel and Skrivan in that the program error rates suggest an approximate log-linear pattern and the individual faults occurred with significantly different error rates. Additional analysis of the experimental data raises new questions concerning the phenomenon of interacting faults. This phenomenon may provide one explanation for software reliability decay.
Evaluation program for secondary spacecraft cells: Seventeenth annual report of cycle life test
NASA Technical Reports Server (NTRS)
Harkness, J. D.
1981-01-01
Acceptance tests were conducted on nickel cadmium, silver cadmium, and silver zinc cells to insure that all cells put into the life cycle program meet the specifications outlined in the respective purchase contracts. Statistical information is presented on cell performance characteristics and limitations. Weaknesses discovered in cell design are reported and aid in research and development efforts toward improving the reliability of space batteries. Battery weaknesses encountered in satellite programs such as IMP, NIMBUS, OGO, OAO, SAS, and TETR were studied and remedied through special tests.
Volumetric CT-images improve testing of radiological image interpretation skills.
Ravesloot, Cécile J; van der Schaaf, Marieke F; van Schaik, Jan P J; ten Cate, Olle Th J; van der Gijp, Anouk; Mol, Christian P; Vincken, Koen L
2015-05-01
Current radiology practice increasingly involves interpretation of volumetric data sets. In contrast, most radiology tests still contain only 2D images. We introduced a new testing tool that allows for stack viewing of volumetric images in our undergraduate radiology program. We hypothesized that tests with volumetric CT-images enhance test quality, in comparison with traditional completely 2D image-based tests, because they might better reflect required skills for clinical practice. Two groups of medical students (n=139; n=143), trained with 2D and volumetric CT-images, took a digital radiology test in two versions (A and B), each containing both 2D and volumetric CT-image questions. In a questionnaire, they were asked to comment on the representativeness for clinical practice, difficulty and user-friendliness of the test questions and testing program. Students' test scores and reliabilities, measured with Cronbach's alpha, of 2D and volumetric CT-image tests were compared. Estimated reliabilities (Cronbach's alphas) were higher for volumetric CT-image scores (version A: .51 and version B: .54), than for 2D CT-image scores (version A: .24 and version B: .37). Participants found volumetric CT-image tests more representative of clinical practice, and considered them to be less difficult than volumetric CT-image questions. However, in one version (A), volumetric CT-image scores (M 80.9, SD 14.8) were significantly lower than 2D CT-image scores (M 88.4, SD 10.4) (p<.001). The volumetric CT-image testing program was considered user-friendly. This study shows that volumetric image questions can be successfully integrated in students' radiology testing. Results suggests that the inclusion of volumetric CT-images might improve the quality of radiology tests by positively impacting perceived representativeness for clinical practice and increasing reliability of the test. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
ERIC Educational Resources Information Center
O'Hare, Thomas; Sherrer, Margaret V.; LaButti, Annamaria; Emrick, Kelly
2004-01-01
Objective/Method: The use of brief, reliable, valid, and practical measures of substance use is critical for conducting individual assessments and program evaluation for integrated mental health-substance abuse services for persons with serious mental illness. This investigation examines the internal consistency reliability, concurrent validity,…
The Infeasibility of Quantifying the Reliability of Life-Critical Real-Time Software
NASA Technical Reports Server (NTRS)
Butler, Ricky W.; Finelli, George B.
1991-01-01
This paper affirms that the quantification of life-critical software reliability is infeasible using statistical methods whether applied to standard software or fault-tolerant software. The classical methods of estimating reliability are shown to lead to exhorbitant amounts of testing when applied to life-critical software. Reliability growth models are examined and also shown to be incapable of overcoming the need for excessive amounts of testing. The key assumption of software fault tolerance separately programmed versions fail independently is shown to be problematic. This assumption cannot be justified by experimentation in the ultrareliability region and subjective arguments in its favor are not sufficiently strong to justify it as an axiom. Also, the implications of the recent multiversion software experiments support this affirmation.
An empirical study of flight control software reliability
NASA Technical Reports Server (NTRS)
Dunham, J. R.; Pierce, J. L.
1986-01-01
The results of a laboratory experiment in flight control software reliability are reported. The experiment tests a small sample of implementations of a pitch axis control law for a PA28 aircraft with over 14 million pitch commands with varying levels of additive input and feedback noise. The testing which uses the method of n-version programming for error detection surfaced four software faults in one implementation of the control law. The small number of detected faults precluded the conduct of the error burst analyses. The pitch axis problem provides data for use in constructing a model in the prediction of the reliability of software in systems with feedback. The study is undertaken to find means to perform reliability evaluations of flight control software.
Statistical complex fatigue data for SAE 4340 steel and its use in design by reliability
NASA Technical Reports Server (NTRS)
Kececioglu, D.; Smith, J. L.
1970-01-01
A brief description of the complex fatigue machines used in the test program is presented. The data generated from these machines are given and discussed. Two methods of obtaining strength distributions from the data are also discussed. Then follows a discussion of the construction of statistical fatigue diagrams and their use in designing by reliability. Finally, some of the problems encountered in the test equipment and a corrective modification are presented.
Hannon, Peggy A.; Helfrich, Christian D.; Chan, K. Gary; Allen, Claire L.; Hammerback, Kristen; Kohn, Marlana J.; Parrish, Amanda T.; Weiner, Bryan J.; Harris, Jeffrey R.
2016-01-01
Purpose To develop a theory-based questionnaire to assess readiness for change in small workplaces adopting wellness programs. Design In developing our scale, we first tested items via “think-aloud” interviews. We tested the revised items in a cross-sectional quantitative telephone survey. Setting Small workplaces (20–250 employees) in low-wage industries. Subjects Decision-makers representing small workplaces in King County, Washington (think-aloud interviews, n=9) and the United States (telephone survey, n=201). Measures We generated items for each construct in Weiner’s theory of organizational readiness for change. We also measured workplace characteristics and current implementation of workplace wellness programs. Analysis We assessed reliability by coefficient alpha for each of the readiness questionnaire subscales. We tested the association of all subscales with employers’ current implementation of wellness policies, programs, and communications, and conducted a path analysis to test the associations in the theory of organizational readiness to change. Results Each of the readiness subscales exhibited acceptable internal reliability (coefficient alpha range = .75–.88) and was positively associated with wellness program implementation (p <.05). The path analysis was consistent with the theory of organizational readiness to change, except change efficacy did not predict change-related effort. Conclusion We developed a new questionnaire to assess small workplaces’ readiness to adopt and implement evidence-based wellness programs. Our findings also provide empirical validation of Weiner’s theory of readiness for change. PMID:26389975
Hannon, Peggy A; Helfrich, Christian D; Chan, K Gary; Allen, Claire L; Hammerback, Kristen; Kohn, Marlana J; Parrish, Amanda T; Weiner, Bryan J; Harris, Jeffrey R
2017-01-01
To develop a theory-based questionnaire to assess readiness for change in small workplaces adopting wellness programs. In developing our scale, we first tested items via "think-aloud" interviews. We tested the revised items in a cross-sectional quantitative telephone survey. The study setting comprised small workplaces (20-250 employees) in low-wage industries. Decision-makers representing small workplaces in King County, Washington (think-aloud interviews, n = 9), and the United States (telephone survey, n = 201) served as study subjects. We generated items for each construct in Weiner's theory of organizational readiness for change. We also measured workplace characteristics and current implementation of workplace wellness programs. We assessed reliability by coefficient alpha for each of the readiness questionnaire subscales. We tested the association of all subscales with employers' current implementation of wellness policies, programs, and communications, and conducted a path analysis to test the associations in the theory of organizational readiness to change. Each of the readiness subscales exhibited acceptable internal reliability (coefficient alpha range, .75-.88) and was positively associated with wellness program implementation ( p < .05). The path analysis was consistent with the theory of organizational readiness to change, except change efficacy did not predict change-related effort. We developed a new questionnaire to assess small workplaces' readiness to adopt and implement evidence-based wellness programs. Our findings also provide empirical validation of Weiner's theory of readiness for change.
CUMBIN - CUMULATIVE BINOMIAL PROGRAMS
NASA Technical Reports Server (NTRS)
Bowerman, P. N.
1994-01-01
The cumulative binomial program, CUMBIN, is one of a set of three programs which calculate cumulative binomial probability distributions for arbitrary inputs. The three programs, CUMBIN, NEWTONP (NPO-17556), and CROSSER (NPO-17557), can be used independently of one another. CUMBIN can be used by statisticians and users of statistical procedures, test planners, designers, and numerical analysts. The program has been used for reliability/availability calculations. CUMBIN calculates the probability that a system of n components has at least k operating if the probability that any one operating is p and the components are independent. Equivalently, this is the reliability of a k-out-of-n system having independent components with common reliability p. CUMBIN can evaluate the incomplete beta distribution for two positive integer arguments. CUMBIN can also evaluate the cumulative F distribution and the negative binomial distribution, and can determine the sample size in a test design. CUMBIN is designed to work well with all integer values 0 < k <= n. To run the program, the user simply runs the executable version and inputs the information requested by the program. The program is not designed to weed out incorrect inputs, so the user must take care to make sure the inputs are correct. Once all input has been entered, the program calculates and lists the result. The CUMBIN program is written in C. It was developed on an IBM AT with a numeric co-processor using Microsoft C 5.0. Because the source code is written using standard C structures and functions, it should compile correctly with most C compilers. The program format is interactive. It has been implemented under DOS 3.2 and has a memory requirement of 26K. CUMBIN was developed in 1988.
The Future of the U.S. Nuclear Weapons Program
NASA Astrophysics Data System (ADS)
Brooks, Linton F.
2007-03-01
This paper will examine our plans for the future of the U.S. nuclear weapons program including efforts to ``transform'' the stockpile and supporting infrastructure. We proceed from the premise that the United States will need a safe, secure, and reliable nuclear deterrent for the foreseeable future. Moreover, the Stockpile Stewardship Program is working. Today's stockpile---comprised of legacy warheads left over from the Cold War---is safe and reliable. That said, we see increased risk, absent nuclear testing, in assuring the long-term safety and reliability of our current stockpile. Nor is today's nuclear weapons complex sufficiently ``responsive'' to fixing technical problems in the stockpile, or to potential adverse geopolitical change. Our task is to work to ensure that the U.S. nuclear weapons enterprise, including the stockpile and supporting infrastructure, meets long-term national security needs. Our approach is to develop and field replacement warheads for the legacy stockpile---so-called Reliable Replacement Warheads (RRW)---as a means to transform both the nuclear stockpile and supporting infrastructure.
NASA Technical Reports Server (NTRS)
1977-01-01
The panel focused its attention on those areas that are considered most significant for flight success and safety. Elements required for the Approach and Landing Test Program, the Orbital Flight Test Program, and those management systems and their implementation which directly affect safety, reliability, and quality control, were investigated. Ground facilities and the training programs for the ground and flight crews were studied. Of special interest was the orbiter thermal protection subsystems.
Evaluation test program, valve, explosive actuated, normally closed Pyronetics model 1400
NASA Technical Reports Server (NTRS)
Avalos, E.
1971-01-01
Evaluation tests of the explosive actuated normally closed valves used to control and isolate hydrazine flow in the TOPS spacecraft, are presented. The malfunctions, modifications, service life, and reliability of the valve are also outlined.
Diode step stress program, JANTX1N5614
NASA Technical Reports Server (NTRS)
1978-01-01
The reliability of switching diode JANTX1N5614 was tested. The effect of power/temperature step stress on the diode was determined. Control sample units were maintained for verification of the electrical parametric testing. Results are reported.
Reliability of a new test battery for fitness assessment of the European Astronaut corps.
Petersen, Nora; Thieschäfer, Lutz; Ploutz-Snyder, Lori; Damann, Volker; Mester, Joachim
2015-01-01
To optimise health for space missions, European astronauts follow specific conditioning programs before, during and after their flights. To evaluate the effectiveness of these programs, the European Space Agency conducts an Astronaut Fitness Assessment (AFA), but the test-retest reliability of elements within it remains unexamined. The reliability study described here presents a scientific basis for implementing the AFA, but also highlights challenges faced by operational teams supporting humans in such unique environments, especially with respect to health and fitness monitoring of crew members travelling not only into space, but also across the world. The AFA tests assessed parameters known to be affected by prolonged exposure to microgravity: aerobic capacity (VO2max), muscular strength (one repetition max, 1 RM) and power (vertical jumps), core stability, flexibility and balance. Intraclass correlation coefficients (ICC3.1), standard error of measurement and coefficient of variation were used to assess relative and absolute test-retest reliability. Squat and bench 1 RM (ICC3.1 = 0.94-0.99), hip flexion (ICC3.1 = 0.99) and left and right handgrip strength (ICC3.1 = 0.95 and 0.97), showed the highest test-retest reliability, followed by VO2max (ICC3.1 = 0.91), core strength (ICC3.1 = 0.78-0.89), hip extension (ICC3.1 = 0.63), the countermeasure (ICC3.1 = 0.76) and squat (ICC3.1 = 0.63) jumps, and single right- and left-leg jump height (ICC3.1 = 0.51 and 0.14). For balance, relative reliability ranged from ICC3.1 = 0.78 for path length (two legs, head tilted back, eyes open) to ICC3.1 = 0.04 for average rotation velocity (one leg, eyes closed). In a small sample (n = 8) of young, healthy individuals, the AFA battery of tests demonstrated acceptable test-retest reliability for most parameters except some balance and single-leg jump tasks. These findings suggest that, for the application with astronauts, most AFA tests appear appropriate to be maintained in the test battery, but that some elements may be unreliable, and require either modification (duration, selection of task) or removal (single-leg jump, balance test on sphere) from the battery. The test battery is mobile and universally applicable for occupational and general fitness assessment by its comprehensive composition of tests covering many systems involved in whole body movement.
A portable battery for objective, non-obstrusive measures of human performances
NASA Technical Reports Server (NTRS)
Kennedy, R. S.
1984-01-01
The need for a standardized battery of human performance tests to measure the effects of various treatments is pointed out. Progress in such a program is reported. Three batteries are available which differ in length and the number of tests in the battery. All tests are implemented on a portable, lap held, briefcase size microprocessor. Performances measured include: information processing, memory, visual perception, reasoning, and motor skills, programs to determine norms, reliabilities, stabilities, factor structure of tests, comparisons with marker tests, apparatus suitability. Rationale for the battery is provided.
B-52 stability augmentation system reliability
NASA Technical Reports Server (NTRS)
Bowling, T. C.; Key, L. W.
1976-01-01
The B-52 SAS (Stability Augmentation System) was developed and retrofitted to nearly 300 aircraft. It actively controls B-52 structural bending, provides improved yaw and pitch damping through sensors and electronic control channels, and puts complete reliance on hydraulic control power for rudder and elevators. The system has experienced over 300,000 flight hours and has exhibited service reliability comparable to the results of the reliability test program. Development experience points out numerous lessons with potential application in the mechanization and development of advanced technology control systems of high reliability.
Medeiros, Lydia C; Hillers, Virginia N; Chen, Gang; Bergmann, Verna; Kendall, Patricia; Schroeder, Mary
2004-11-01
The objective of this study was to design and develop food safety knowledge and attitude scales based on food-handling guidelines developed by a national panel of food safety experts. Knowledge (n=43) and attitude (n=49) questions were developed and pilot-tested with a variety of consumer groups. Final questions were selected based on item analysis and on validity and reliability statistical tests. Knowledge questions were tested in Washington State with participants in low-income nutrition education programs (pretest/posttest n=58, test/retest n=19) and college students (pretest/posttest n=34). Attitude questions were tested in Ohio with nutrition education program participants (n=30) and college students (non-nutrition majors n=138, nutrition majors n=57). Item analysis, paired sample t tests, Pearson's correlation coefficients, and Cronbach's alpha were used. Reliability and validity tests of individual items and the question sets were used to reduce the scales to 18 knowledge questions and 10 attitude questions. The knowledge and attitude scales covered topics ranked as important by a national panel of experts and met most validity and reliability standards. The 18-item knowledge questionnaire had instructional sensitivity (mean score increase of more than three points after instruction), internal reliability (Cronbach's alpha >.75), and produced similar results in test-retest without intervention (coefficient of stability=.81). Knowledge of correct procedures for hand washing and avoiding cross-contamination was widespread before instruction. Knowledge was limited regarding avoiding food preparation while ill, cooking hamburgers, high-risk foods, and whether cooked rice and potatoes could be stored at room temperature. The 10-item attitude scale had an appropriate range of responses (item difficulty) and produced similar results in test-retest ( P =.01). Internal consistency ranged from alpha=.63 to .89. Students anticipating a career where food safety is valued had higher attitude scale scores than participants of extension education programs. Uses for the knowledge questionnaire include assessment of subject matter knowledge before instruction and knowledge gain after instruction. The attitude scale assesses an outcome variable that may predict food safety behavior.
Digital electronic engine control history
NASA Technical Reports Server (NTRS)
Putnam, T. W.
1984-01-01
Full authority digital electronic engine controls (DEECs) were studied, developed, and ground tested because of projected benefits in operability, improved performance, reduced maintenance, improved reliability, and lower life cycle costs. The issues of operability and improved performance, however, are assessed in a flight test program. The DEEC on a F100 engine in an F-15 aircraft was demonstrated and evaluated. The events leading to the flight test program are chronicled and important management and technical results are identified.
ERIC Educational Resources Information Center
University of Central Florida, Orlando. Coll. of Education.
This report describes the production and pilot test of an assessment instrument for vocational education programs. The instrument was designed to be used following a site visit that includes a 30- to 45-minute interview with the program instructor and a 30-minute interview with one small group of students. Reliability and validity information was…
Time-Tagged Risk/Reliability Assessment Program for Development and Operation of Space System
NASA Astrophysics Data System (ADS)
Kubota, Yuki; Takegahara, Haruki; Aoyagi, Junichiro
We have investigated a new method of risk/reliability assessment for development and operation of space system. It is difficult to evaluate risk of spacecraft, because of long time operation, maintenance free and difficulty of test under the ground condition. Conventional methods are FMECA, FTA, ETA and miscellaneous. These are not enough to assess chronological anomaly and there is a problem to share information during R&D. A new method of risk and reliability assessment, T-TRAP (Time-tagged Risk/Reliability Assessment Program) is proposed as a management tool for the development and operation of space system. T-TRAP consisting of time-resolved Fault Tree and Criticality Analyses, upon occurrence of anomaly in the system, facilitates the responsible personnel to quickly identify the failure cause and decide corrective actions. This paper describes T-TRAP method and its availability.
McKenna, J.E.
2003-01-01
The biosphere is filled with complex living patterns and important questions about biodiversity and community and ecosystem ecology are concerned with structure and function of multispecies systems that are responsible for those patterns. Cluster analysis identifies discrete groups within multivariate data and is an effective method of coping with these complexities, but often suffers from subjective identification of groups. The bootstrap testing method greatly improves objective significance determination for cluster analysis. The BOOTCLUS program makes cluster analysis that reliably identifies real patterns within a data set more accessible and easier to use than previously available programs. A variety of analysis options and rapid re-analysis provide a means to quickly evaluate several aspects of a data set. Interpretation is influenced by sampling design and a priori designation of samples into replicate groups, and ultimately relies on the researcher's knowledge of the organisms and their environment. However, the BOOTCLUS program provides reliable, objectively determined groupings of multivariate data.
Preliminary evaluation of a micro-based repeated measures testing system
NASA Technical Reports Server (NTRS)
Kennedy, Robert S.; Wilkes, Robert L.; Lane, Norman E.
1985-01-01
A need exists for an automated performance test system to study the effects of various treatments which are of interest to the aerospace medical community, i.e., the effects of drugs and environmental stress. The ethics and pragmatics of such assessment demand that repeated measures in small groups of subjects be the customary research paradigm. Test stability, reliability-efficiency and factor structure take on extreme significance; in a program of study by the U.S. Navy, 80 percent of 150 tests failed to meet minimum metric requirements. The best is being programmed on a portable microprocessor and administered along with tests in their original formats in order to examine their metric properties in the computerized mode. Twenty subjects have been tested over four replications on a 6.0 minute computerized battery (six tests) and which compared with five paper and pencil marker tests. All tests achieved stability within the four test sessions, reliability-efficiencies were high (r greater than .707 for three minutes testing), and the computerized tests were largely comparable to the paper and pencil version from which they were derived. This computerized performance test system is portable, inexpensive and rugged.
Yun, Young Ho; Sim, Jin Ah; Lim, Ye Jin; Lim, Cheol Il; Kang, Sung-Choon; Kang, Joon-Ho; Park, Jun Dong; Noh, Dong Young
2016-06-01
The objective of this study was to develop the Worksite Health Index (WHI) and validate its psychometric properties. The development of the WHI questionnaire included item generation, item construction, and field testing. To assess the instrument's reliability and validity, we recruited 30 different Korean worksites. We developed the WHI questionnaire of 136 items categorized into five domains, namely Governance and Infrastructure, Need Assessment and Planning, Health Prevention and Promotion Program, Occupational Safety, and Monitoring and Feedback. All WHI domains demonstrated a high reliability with good internal consistency. The total WHI scores differentiated worksite groups effectively according to firm size. Each domain was associated significantly with employees' health status, absence, and financial outcome. The WHI can assess comprehensive worksite health programs. This tool is publicly available for addressing the growing need for worksite health programs.
The safety and reliability of the S and A mechanism designed for the NASA/LSPE program
NASA Technical Reports Server (NTRS)
Montesi, L. J.
1973-01-01
Under contract to the Manned Spacecraft Center, NASA/Houston, NOL developed a number of explosive charges for use in studying the surface of the moon during Apollo 17 activities. The charges were part of the Lunar Seismic Profiling Experiment (LSPE). When the Safety and Arming Device used in the previous ALSEP experiments was found unsuitable for use with the new explosive packages, NOL also designed the Safety and Arming Mechanism, and the safety and reliability tests conducted are described. The results of the test program indicate that the detonation transfer probability between the armed explosive components exceeds 0.9999, and is less than 0.0001 when the explosive components are in the safe position.
ERIC Educational Resources Information Center
Sun, Anji; Valiga, Michael J.
In this study, the reliability of the American College Testing (ACT) Program's "Survey of Academic Advising" (SAA) was examined using both univariate and multivariate generalizability theory approaches. The primary purpose of the study was to compare the results of three generalizability theory models (a random univariate model, a mixed…
The predictive information obtained by testing multiple software versions
NASA Technical Reports Server (NTRS)
Lee, Larry D.
1987-01-01
Multiversion programming is a redundancy approach to developing highly reliable software. In applications of this method, two or more versions of a program are developed independently by different programmers and the versions are combined to form a redundant system. One variation of this approach consists of developing a set of n program versions and testing the versions to predict the failure probability of a particular program or a system formed from a subset of the programs. The precision that might be obtained, and also the effect of programmer variability if predictions are made over repetitions of the process of generating different program versions, are examined.
NASA Electronic Parts and Packaging Program
NASA Technical Reports Server (NTRS)
Kayali, Sammy
2000-01-01
NEPP program objectives are to: (1) Access the reliability of newly available electronic parts and packaging technologies for usage on NASA projects through validations, assessments, and characterizations, and the development of test methods/tools; (2)Expedite infusion paths for advanced (emerging) electronic parts and packaging technologies by evaluations of readiness for manufacturability and project usage consideration; (3) Provide NASA projects with technology selection, application, and validation guidelines for electronic parts and packaging hardware and processes; nd (4) Retain and disseminate electronic parts and packaging quality assurance, reliability validations, tools, and availability information to the NASA community.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Roedel, S.
1979-06-01
The purpose of the receptacle test program was to test various types of hermetically sealed electrical receptacles and to select one model as the spaceflight hardware item for SIG/Galileo thermoelectric generators. The design goal of the program was to qualify a hermetic seal integrity of less than or equal to 1 x 10/sup -9/ std cc He/sec -atm at 400/sup 0/F (204/sup 0/C) and verify a reliability of 0.95 at a 50% confidence level for a flight mission in excess of 7 years.
Diagnostic reliability of MMPI-2 computer-based test interpretations.
Pant, Hina; McCabe, Brian J; Deskovitz, Mark A; Weed, Nathan C; Williams, John E
2014-09-01
Reflecting the common use of the MMPI-2 to provide diagnostic considerations, computer-based test interpretations (CBTIs) also typically offer diagnostic suggestions. However, these diagnostic suggestions can sometimes be shown to vary widely across different CBTI programs even for identical MMPI-2 profiles. The present study evaluated the diagnostic reliability of 6 commercially available CBTIs using a 20-item Q-sort task developed for this study. Four raters each sorted diagnostic classifications based on these 6 CBTI reports for 20 MMPI-2 profiles. Two questions were addressed. First, do users of CBTIs understand the diagnostic information contained within the reports similarly? Overall, diagnostic sorts of the CBTIs showed moderate inter-interpreter diagnostic reliability (mean r = .56), with sorts for the 1/2/3 profile showing the highest inter-interpreter diagnostic reliability (mean r = .67). Second, do different CBTIs programs vary with respect to diagnostic suggestions? It was found that diagnostic sorts of the CBTIs had a mean inter-CBTI diagnostic reliability of r = .56, indicating moderate but not strong agreement across CBTIs in terms of diagnostic suggestions. The strongest inter-CBTI diagnostic agreement was found for sorts of the 1/2/3 profile CBTIs (mean r = .71). Limitations and future directions are discussed. PsycINFO Database Record (c) 2014 APA, all rights reserved.
10 CFR 712.11 - General requirements for HRP certification.
Code of Federal Regulations, 2010 CFR
2010-01-01
..., “Drug-Free Federal Workplace Testing Implementation Program,” for DOE employees; (9) An initial alcohol... the HRP and complete initial instruction on the importance of security, safety, reliability, and... the Manager, the NNSA Administrator, his or her designee, or the appropriate Lead Program Secretarial...
NASA Technical Reports Server (NTRS)
Harkness, J. D.
1976-01-01
Considerable research is being done to find more efficient and reliable means of starting electrical energy for orbiting satellites. Rechargeable cells offer one such means. A test program is described which has been established in order to further the evaluation of certain types of cells and to obtain performance and failure data as an aid to their continued improvement. The purpose of the program is to determine the cycling performance capabilities of packs of cells under different load and temperature conditions. The various kinds of cells tested were nickel-cadmium, silver-cadmium, and silver-zinc sealed cells. A summary of the results of the life cycling program is given in this report.
Reliability of programs specified with equational specifications
NASA Astrophysics Data System (ADS)
Nikolik, Borislav
Ultrareliability is desirable (and sometimes a demand of regulatory authorities) for safety-critical applications, such as commercial flight-control programs, medical applications, nuclear reactor control programs, etc. A method is proposed, called the Term Redundancy Method (TRM), for obtaining ultrareliable programs through specification-based testing. Current specification-based testing schemes need a prohibitively large number of testcases for estimating ultrareliability. They assume availability of an accurate program-usage distribution prior to testing, and they assume the availability of a test oracle. It is shown how to obtain ultrareliable programs (probability of failure near zero) with a practical number of testcases, without accurate usage distribution, and without a test oracle. TRM applies to the class of decision Abstract Data Type (ADT) programs specified with unconditional equational specifications. TRM is restricted to programs that do not exceed certain efficiency constraints in generating testcases. The effectiveness of TRM in failure detection and recovery is demonstrated on formulas from the aircraft collision avoidance system TCAS.
The Shock and Vibration Digest, Volume 14, Number 4
1982-04-01
temperature, humidity, shock, and vibration -- can influence this capability; as a result an almost continuous program of research and development has...pro- ducing reliability tests. For some time there has been interest in the Army Test Methodology program for developing a vibration system capable...geology of the Livermore Valley is obtained. 82-768 Transient Stress Wave Propagation in HTGR Fuel Element Impacts I.T. Almajan and P.D. Smith
Performance Evaluation Tests for Environmental Research (PETER): evaluation of 114 measures
NASA Technical Reports Server (NTRS)
Bittner, A. C. Jr; Carter, R. C.; Kennedy, R. S.; Harbeson, M. M.; Krause, M.
1986-01-01
The goal of the Performance Evaluation Tests for Environmental Research (PETER) Program was to identify a set of measures of human capabilities for use in the study of environmental and other time-course effects. 114 measures studied in the PETER Program were evaluated and categorized into four groups based upon task stability and task definition. The Recommended category contained 30 measures that clearly obtained total stabilization and had an acceptable level of reliability efficiency. The Acceptable-But-Redundant category contained 15 measures. The 37 measures in the Marginal category, which included an inordinate number of slope and other derived measures, usually had desirable features which were outweighed by faults. The 32 measures in the Unacceptable category had either differential instability or weak reliability efficiency. It is our opinion that the 30 measures in the Recommended category should be given first consideration for environmental research applications. Further, it is recommended that information pertaining to preexperimental practice requirements and stabilized reliabilities should be utilized in repeated-measures environmental studies.
Development and reliability testing of the Worksite and Energy Balance Survey.
Hoehner, Christine M; Budd, Elizabeth L; Marx, Christine M; Dodson, Elizabeth A; Brownson, Ross C
2013-01-01
Worksites represent important venues for health promotion. Development of psychometrically sound measures of worksite environments and policy supports for physical activity and healthy eating are needed for use in public health research and practice. Assess the test-retest reliability of the Worksite and Energy Balance Survey (WEBS), a self-report instrument for assessing perceptions of worksite supports for physical activity and healthy eating. The WEBS included items adapted from existing surveys or new items on the basis of a review of the literature and expert review. Cognitive interviews among 12 individuals were used to test the clarity of items and further refine the instrument. A targeted random-digit-dial telephone survey was administered on 2 occasions to assess test-retest reliability (mean days between time periods = 8; minimum = 5; maximum = 14). Five Missouri census tracts that varied by racial-ethnic composition and walkability. Respondents included 104 employed adults (67% white, 64% women, mean age = 48.6 years). Sixty-three percent were employed at worksites with less than 100 employees, approximately one-third supervised other people, and the majority worked a regular daytime shift (75%). Test-retest reliability was assessed using Spearman correlations for continuous variables, Cohen's κ statistics for nonordinal categorical variables, and 1-way random intraclass correlation coefficients for ordinal categorical variables. Test-retest coefficients ranged from 0.41 to 0.97, with 80% of items having reliability coefficients of more than 0.6. Items that assessed participation in or use of worksite programs/facilities tended to have lower reliability. Reliability of some items varied by gender, obesity status, and worksite size. Test-retest reliability and internal consistency for the 5 scales ranged from 0.84 to 0.94 and 0.63 to 0.84, respectively. The WEBS items and scales exhibited sound test-retest reliability and may be useful for research and surveillance. Further evaluation is needed to document the validity of the WEBS and associations with energy balance outcomes.
Valid and Reliable Science Content Assessments for Science Teachers
NASA Astrophysics Data System (ADS)
Tretter, Thomas R.; Brown, Sherri L.; Bush, William S.; Saderholm, Jon C.; Holmes, Vicki-Lynn
2013-03-01
Science teachers' content knowledge is an important influence on student learning, highlighting an ongoing need for programs, and assessments of those programs, designed to support teacher learning of science. Valid and reliable assessments of teacher science knowledge are needed for direct measurement of this crucial variable. This paper describes multiple sources of validity and reliability (Cronbach's alpha greater than 0.8) evidence for physical, life, and earth/space science assessments—part of the Diagnostic Teacher Assessments of Mathematics and Science (DTAMS) project. Validity was strengthened by systematic synthesis of relevant documents, extensive use of external reviewers, and field tests with 900 teachers during assessment development process. Subsequent results from 4,400 teachers, analyzed with Rasch IRT modeling techniques, offer construct and concurrent validity evidence.
Determining the Appropriateness of the "What If" Situations Test (WIST) with Turkish Pre-Schoolers.
Citak Tunc, Gulseren; Gorak, Gulay; Ozyazicioglu, Nurcan; Ak, Bedriye; Isil, Ozlem; Vural, Pinar
2018-04-01
Measurement instruments are needed to assess the child's sexual abuse prevention program. The purpose of the study was to determine the reliability and validity of the WIST (What If Situations Test) for Turkish culture. Participants were children of the 3-6 age group attending pre-school education institutions and the sample size was identified by means of a power analysis. Seventy children were identified as the sample with 0.85 power and 0.05 type I error according to the power analysis. Language validity, content validity, internal validity coefficient (Cronbach alpha coefficient), and test-retest analyses were conducted in terms of validity and reliability in the scope of efforts for adaptation to Turkish culture. Firstly, Kendall W = 0.83 was the score for the expert opinions concerning the content validity of the language validity scale. It was found that the Cronbach alpha coefficients were between 0.68 and 0.90 for the scale sub-dimensions of appropriate and inappropriate recognition, saying, doing, telling, and reporting. The test-retest reliability of the scale was found to be r = 0.89 and the test-retest reliabilities for the sub-dimensions (appropriate recognition, inappropriate recognition, say skills, do skills, tell skills, and reporting skills) were between r = 0.48 and r = 0.92. The test-retest reliability for the Personal Safety Questionnaire (PSQ), as having complimentary items to the WIST, was found to be r = 0.82. The reliability and validity analysis of the 'What If' Situations Test (WIST), used to evaluate pre-schoolers' skills regarding self-protection against sexual abuse, showed that the Test's adaptation to Turkish culture was reliable and valid.
Large-Scale Multiobjective Static Test Generation for Web-Based Testing with Integer Programming
ERIC Educational Resources Information Center
Nguyen, M. L.; Hui, Siu Cheung; Fong, A. C. M.
2013-01-01
Web-based testing has become a ubiquitous self-assessment method for online learning. One useful feature that is missing from today's web-based testing systems is the reliable capability to fulfill different assessment requirements of students based on a large-scale question data set. A promising approach for supporting large-scale web-based…
Aligning Scales of Certification Tests. Research Report. ETS RR-10-07
ERIC Educational Resources Information Center
Dorans, Neil J.; Liang, Longjuan; Puhan, Gautam
2010-01-01
Scores are the most visible and widely used products of a testing program. The choice of score scale has implications for test specifications, equating, and test reliability and validity, as well as for test interpretation. At the same time, the score scale should be viewed as infrastructure likely to require repair at some point. In this report…
Missile and Space Systems Reliability versus Cost Trade-Off Study
1983-01-01
F00-1C09 Robert C. Schneider F00-1C09 V . PERFORMING ORGANIZATION NAME AM0 ADDRESS 16 PRGRAM ELEMENT. PROJECT. TASK BoeingAerosace CmpAnyA CA WORK UNIT...reliability problems, which has the - real bearing on program effectiveness. A well planned and funded reliability effort can prevent or ferret out...failure analysis, and the in- corporation and verification of design corrections to prevent recurrence of failures. 302.2.2 A TMJ test plan shall be
10 CFR 712.11 - General requirements for HRP certification.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 10 Energy 4 2013-01-01 2013-01-01 false General requirements for HRP certification. 712.11 Section 712.11 Energy DEPARTMENT OF ENERGY HUMAN RELIABILITY PROGRAM Establishment of and Procedures for the..., “Drug-Free Federal Workplace Testing Implementation Program,” for DOE employees; (9) An initial alcohol...
10 CFR 712.11 - General requirements for HRP certification.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 10 Energy 4 2012-01-01 2012-01-01 false General requirements for HRP certification. 712.11 Section 712.11 Energy DEPARTMENT OF ENERGY HUMAN RELIABILITY PROGRAM Establishment of and Procedures for the..., “Drug-Free Federal Workplace Testing Implementation Program,” for DOE employees; (9) An initial alcohol...
10 CFR 712.11 - General requirements for HRP certification.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 4 2011-01-01 2011-01-01 false General requirements for HRP certification. 712.11 Section 712.11 Energy DEPARTMENT OF ENERGY HUMAN RELIABILITY PROGRAM Establishment of and Procedures for the..., “Drug-Free Federal Workplace Testing Implementation Program,” for DOE employees; (9) An initial alcohol...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Patton, A.D.; Ayoub, A.K.; Singh, C.
1982-07-01
This report describes the structure and operation of prototype computer programs developed for a Monte Carlo simulation model, GENESIS, and for two analytical models, OPCON and OPPLAN. It includes input data requirements and sample test cases.
ERIC Educational Resources Information Center
Francis, Leslie John
The purpose of this study was to provide an in-depth analysis of vision-screening programs in relation to their efficacy, appropriateness, and feasibility for public school use. Twenty-two vision-screening programs were analyzed for reliability, validity, efficiency of identification and referral cost, and required testing time. Findings are that…
ERIC Educational Resources Information Center
Mahasneh, Omar. M.; Farajat, Amani. M.
2015-01-01
The present research was conducted to identify the effectiveness of a training program based on practice of careers in vocational interests development, to answer questions about the study and test its hypothesis the training program had been prepared and the adoption of a measure of vocational interests, as validity and reliability of each of…
Aligning English Language Testing with Curriculum
ERIC Educational Resources Information Center
Palacio, Marcela; Gaviria, Sandra; Brown, James Dean
2016-01-01
Frustrations with traditional testing led a group of teachers at the English for adults program at Universidad EAFIT (Colombia) to design tests aligned with the institutional teaching philosophy and classroom practices. This article reports on a study of an item-by-item evaluation of a series of English exams for validity and reliability in an…
Tracer testing is generally regarded as the most reliable and efficient method of gathering surface and subsurface hydraulic information. This is especially true for karstic and fractured-rock aquifers. Qualitative tracing tests have been conventionally employed in most karst s...
Photovoltaic module reliability improvement through application testing and failure analysis
NASA Technical Reports Server (NTRS)
Dumas, L. N.; Shumka, A.
1982-01-01
During the first four years of the U.S. Department of Energy (DOE) National Photovoltatic Program, the Jet Propulsion Laboratory Low-Cost Solar Array (LSA) Project purchased about 400 kW of photovoltaic modules for test and experiments. In order to identify, report, and analyze test and operational problems with the Block Procurement modules, a problem/failure reporting and analysis system was implemented by the LSA Project with the main purpose of providing manufacturers with feedback from test and field experience needed for the improvement of product performance and reliability. A description of the more significant types of failures is presented, taking into account interconnects, cracked cells, dielectric breakdown, delamination, and corrosion. Current design practices and reliability evaluations are also discussed. The conducted evaluation indicates that current module designs incorporate damage-resistant and fault-tolerant features which address field failure mechanisms observed to date.
A Comprehensive Well Testing Implementation during Exploration Phase in Rantau Dedap, Indonesia
NASA Astrophysics Data System (ADS)
Humaedi, M. T.; Alfiady; Putra, A. P.; Martikno, R.; Situmorang, J.
2016-09-01
This paper describes the implementation of comprehensive well testing programs during the 2014-2015 exploration drilling in Rantau Dedap Geothermal Field. The well testing programs were designed to provide reliable data as foundation for resource assessment as well as useful information for decision making during drilling. A series of well testing survey consisting of SFTT, completion test, heating-up downhole logging, discharge test, chemistry sampling was conducted to understand individual wells characteristics such as thermodynamic state of the reservoir fluid, permeability distribution, well output and fluid chemistry. Furthermore, interference test was carried out to investigate the response of reservoir to exploitation.
Effects of back posture education on elementary schoolchildren's back function.
Geldhof, Elisabeth; Cardon, Greet; De Bourdeaudhuij, Ilse; Danneels, Lieven; Coorevits, Pascal; Vanderstraeten, Guy; De Clercq, Dirk
2007-06-01
The possible effects of back education on children's back function were never evaluated. Therefore, main aim of the present study was to evaluate the effects of back education in elementary schoolchildren on back function parameters. Since the reliability of back function measurement in children is poorly defined, another objective was to test the selected instruments for reliability in 8-11-year olds. The multi-factorial intervention lasting two school-years consisted of a back education program and the stimulation of postural dynamism in the class. Trunk muscle endurance, leg muscle capacity and spinal curvature were evaluated in a pre-post design including 41 children who received the back education program (mean age at post-test: 11.2 +/- 0.9 years) and 28 controls (mean age at post-test: 11.4 +/- 0.6 years). Besides, test-retest reliability with a 1-week interval was investigated in a separate sample. Therefore, 47 children (mean age: 10.1 +/- 0.5 years) were tested for reliability of trunk muscle endurance and 40 children (mean age: 10.2 +/- 0.7 years) for the assessment of spinal curvatures. Reliability of endurance testing was very good to good for the trunk flexors (ICC = 0.82) and trunk extensors (ICC = 0.63). The assessment of the thoracic (ICC = 0.69) and the lumbar curvature (ICC = 0.52) in seating position showed good to acceptable reliability. Low ICCs were found for the assessment of the thoracic (ICC = 0.39) and the lumbar curvature (ICC = 0.37) in stance. The effects of 2 year back education showed an increase in trunk flexor endurance in the intervention group compared to a decrease in the controls and a trend towards significance for a higher increase in trunk extensor endurance in the intervention group. For leg muscle capacity and spinal curvature no intervention effects were found. The small samples recommend cautious interpretation of intervention effects. However, the present study's findings favor the implementation of back education with focus on postural dynamism in the class as an integral part of the elementary school curriculum in the scope of optimizing spinal loading through the school environment.
An investigation of a sterile access technique for the repair and adjustment of sterile spacecraft
NASA Technical Reports Server (NTRS)
Farmer, F. H.; Fuller, H. V.; Hueschen, R. M.
1973-01-01
A description is presented of a unique system for the sterilization and sterile repair of spacecraft and the results of a test program designed to assess the biological integrity and engineering reliability of the system. This trailer-mounted system, designated the model assembly sterilizer for testing (MAST), is capable of the dry-heat sterilization of spacecraft and/or components less than 2.3 meters in diameter at temperatures up to 433 K and the steam sterilization of components less than 0.724 meter in diameter. Sterile access to spacecraft is provided by two tunnel suits, called the bioisolator suit systems (BISS), which are contiguous with the walls of the sterilization chambers. The test program was designed primarily to verify the biological and engineering reliability of the MAST system by processing simulated space hardware. Each test cycle simulated the initial sterilization of a spacecraft, sterile repair of a failed component, removal of the spacecraft from the MAST for mating with the bus, and a sterile recycle repair.
Reliability of a Market Basket Assessment Tool (MBAT) for Use in SNAP-Ed Healthy Retail Initiatives.
Misyak, Sarah A; Hedrick, Valisa E; Pudney, Ellen; Serrano, Elena L; Farris, Alisha R
2018-05-01
To evaluate the reliability of the Market Basket Assessment Tool (MBAT) for assessing the availability of fruits and vegetables, low-fat or nonfat dairy and eggs, lean meats, whole-grain products, and seeds, beans, and nuts in Supplemental Nutrition Assistance Program-authorized retail environments. Different trained raters used the MBAT simultaneously at 14 retail environments to measure interrater reliability. Raters returned to 12 retail environments (85.7%) 1 week later to measure test-retest reliability. Data were analyzed using paired-sample t tests and correlations. No significant differences were found for interrater reliability or test-retest reliability for individual categories (mean differences, 0.0 to 0.3 ± 0.2 points) or total score (mean difference, 0.5 ± 0.4 points and (mean differences, 0.0 to 0.3 ± 0.3 points) or total score (mean difference, 0.8 ± 0.4 points), respectively. Future steps include validation of the MBAT. A low-burden tool can facilitate evaluation of efforts to promote healthful foods in retail environments. Copyright © 2018 Society for Nutrition Education and Behavior. Published by Elsevier Inc. All rights reserved.
NASA flight cell and battery issues
NASA Technical Reports Server (NTRS)
Schulze, N. R.
1989-01-01
The author presents the important battery and cell problems, encompassing both test failures and accidents, which were encountered during the past year. Practical issues facing programs, which have to be considered in the development of a battery program strategy, are addressed. The problems of one program, the GRO (Gamma Ray Observatory), during the past year are focused on to illustrate the fundamental types of battery problems that occur. Problems encountered by other programs are briefly mentioned to complete the accounting. Two major categories of issues are defined, namely, whose which are quality and design related, i.e., problems having inherent manufacturing-process-related aspects with an impact on cell reliability, and these which are accident triggered or man induced, i.e., those operational issues having an impact on battery and cell reliability.
NASA Astrophysics Data System (ADS)
Black, Stephen T.; Eshleman, Wally
1997-01-01
This paper describes the VentureStar™ SSTO RLV and X-33 operations concepts. Applications of advanced technologies, automated ground support systems, advanced aircraft and launch vehicle lessons learned have been integrated to develop a streamlined vehicle and mission processing concept necessary to meet the goals of a commercial SSTO RLV. These concepts will be validated by the X-33 flight test program where financial and technical risk mitigation are required. The X-33 flight test program totally demonstrates the vehicle performance, technology, and efficient ground operations at the lowest possible cost. The Skunk Work's test program approach and test site proximity to the production plant are keys. The X-33 integrated flight and ground test program incrementally expands the knowledge base of the overall system allowing minimum risk progression to the next flight test program milestone. Subsequent X-33 turnaround processing flows will be performed with an aircraft operations philosophy. The differences will be based on research and development, component reliability and flight test requirements.
NASA Technical Reports Server (NTRS)
1973-01-01
The ALERT program, a system for communicating common problems with parts, materials, and processes, is condensed and catalogued. Expanded information on selected topics is provided by relating the problem area (failure) to the cause, the investigations and findings, the suggestions for avoidance (inspections, screening tests, proper part applications), and failure analysis procedures. The basic objective of ALERT is the avoidance of the recurrence of parts, materials, and processed problems, thus improving the reliability of equipment produced for and used by the government.
The major objective of the HAZCON Solidification SITE Program Demonstration Test was to develop reliable performance and cost information. The demonstration occurred at a 50-acre site of a former oil reprocessing plant at Douglassville, PA containing a wide range of organic...
King, Thomas C; Upfal, Mark; Gottlieb, Andrew; Adamo, Philip; Bernacki, Edward; Kadlecek, Chris P; Jones, Jeffrey G; Humphrey-Carothers, Frances; Rielly, Albert F; Drewry, Pamela; Murray, Kathy; DeWitt, Marcie; Matsubara, Janet; O'Dea, Louis; Balser, John; Wrighton-Smith, Peter
2015-08-01
Interferon-γ release assays have significant advantages over tuberculin skin testing in many clinical situations. However, recent studies have called into question their reliability in serial testing of healthcare workers because of reportedly high rates of positivity and high conversion/reversion rates on retesting. To define the performance characteristics of the T-SPOT.TB test, an interferon-γ release assay, during serial screening programs of healthcare workers at 19 U.S. hospitals. A total of 42,155 T-SPOT.TB test results from healthcare workers at 19 geographically diverse hospitals obtained for routine tuberculosis screening programs were analyzed to determine the rates of positivity, reversion, and conversion in serial testing data. In 19,630 evaluable serial pairs from 16,076 healthcare workers, the mean test positivity rate was 2.3% (range, 0.0-27.4%). The mean conversion rate was 0.8% (range, 0.0-2.5%), and the mean reversion rate was 17.6%. Positivity and conversion rates correlated with known tuberculosis risk factors including age and sex. The observed specificity of the T-SPOT.TB test was at least 98.6%. The high concordance and test completion rates in this study suggest that the T-SPOT.TB test is a reliable tool for healthcare worker serial screening. As expected, the observed positivity rates were lower compared with the tuberculin skin test, likely reflecting the higher specificity of this test. Furthermore, the observed rates of conversion were low and significantly correlated with the geographic incidence of tuberculosis. Our findings suggest that the T-SPOT.TB test is an accurate and reliable way to screen healthcare workers.
The advisability of prototypic testing for space nuclear systems
NASA Astrophysics Data System (ADS)
Lenard, Roger X.
2005-07-01
From October 1987 until 1993, the US Department of Defense conducted the Space Nuclear Thermal Propulsion program. This program's objective was to design and develop a high specific impulse, high thrust-to-weight nuclear thermal rocket engine for upper stage applications. The author was the program manager for this program until 1992. Numerous analytical, programmatic and experimental results were generated during this period of time. This paper reviews the accomplishments of the program and highlights the importance of prototypic testing for all aspects of a space nuclear program so that a reliable and safe system compliant with all regulatory requirements can be effectively engineered. Specifically, the paper will recount how many non-prototypic tests we performed only to have more representative tests consistently generate different results. This was particularly true in area of direct nuclear heat generation. As nuclear tests are generally much more expensive than non-nuclear tests, programs attempt to avoid such tests in favor of less expensive non-nuclear tests. Each time this approach was followed, the SNTP program found these tests to not be verified by nuclear heated testing. Hence the author recommends that wherever possible, a spiral development approach that includes exploratory and confirmatory experimental testing be employed to ensure a viable design.
Implementation of Wireless and Intelligent Sensor Technologies in the Propulsion Test Environment
NASA Technical Reports Server (NTRS)
Solano, Wanda M.; Junell, Justin C.; Shumard, Kenneth
2003-01-01
From the first Saturn V rocket booster (S-II-T) testing in 1966 and the routine Space Shuttle Main Engine (SSME) testing beginning in 1975, to more recent test programs such as the X-33 Aerospike Engine, the Integrated Powerhead Development (IPD) program, and the Hybrid Sounding Rocket (HYSR), Stennis Space Center (SSC) continues to be a premier location for conducting large-scale propulsion testing. Central to each test program is the capability for sensor systems to deliver reliable measurements and high quality data, while also providing a means to monitor the test stand area to the highest degree of safety and sustainability. As part of an on-going effort to enhance the testing capabilities of Stennis Space Center, the Test Technology and Development group is developing and applying a number of wireless and intelligent sensor technologies in ways that are new to the test existing test environment.
Advanced flight control system study
NASA Technical Reports Server (NTRS)
Mcgough, J.; Moses, K.; Klafin, J. F.
1982-01-01
The architecture, requirements, and system elements of an ultrareliable, advanced flight control system are described. The basic criteria are functional reliability of 10 to the minus 10 power/hour of flight and only 6 month scheduled maintenance. A distributed system architecture is described, including a multiplexed communication system, reliable bus controller, the use of skewed sensor arrays, and actuator interfaces. Test bed and flight evaluation program are proposed.
Technology Overview for Advanced Aircraft Armament System Program.
1981-05-01
availability of methods or systems for improving stores and armament safety. Of particular importance are aspects of safety involving hazards analysis ...flutter virtually insensitive to inertia and center-of- gravity location of store - Simplifies and reduces analysis and testing required to flutter- clear...status. Nearly every existing reliability analysis and discipline that prom- ised a positive return on reliability performance was drawn out, dusted
ERIC Educational Resources Information Center
Lincove, Jane Arnold; Osborne, Cynthia; Dillon, Amanda; Mills, Nicholas
2014-01-01
Despite questions about validity and reliability, the use of value-added estimation methods has moved beyond academic research into state accountability systems for teachers, schools, and teacher preparation programs (TPPs). Prior studies of value-added measurement for TPPs test the validity of researcher-designed models and find that measuring…
Transistor step stress program for JANTX2N4150
NASA Technical Reports Server (NTRS)
1979-01-01
Reliability analysis of the transistor JANTX2N4150 manufactured by General Semiconductor and Transitron is reported. The discrete devices were subjected to power and temperature step stress tests and then to electrical tests after completing the power/temperature step stress point. Control sample units were maintained for verification of the electrical parametric testing. Results are presented.
Quality management for space systems in ISRO
NASA Astrophysics Data System (ADS)
Satish, S.; Selva Raju, S.; Nanjunda Swamy, T. S.; Kulkarni, P. L.
2009-11-01
In a little over four decades, the Indian Space Program has carved a niche for itself with the unique application driven program oriented towards National development. The end-to-end capability approach of the space projects in the country call for innovative practices and procedures in assuring the quality and reliability of space systems. The System Reliability (SR) efforts initiated at the start of the projects continue during the entire life cycle of the project encompassing design, development, realisation, assembly, testing and integration and during launch. Even after the launch, SR groups participate in the on-orbit evaluation of transponders in communication satellites and camera systems in remote sensing satellites. SR groups play a major role in identification, evaluation and inculcating quality practices in work centres involved in the fabrication of mechanical, electronics and propulsion systems required for Indian Space Research Organization's (ISRO's) launch vehicle and spacecraft projects. Also the reliability analysis activities like prediction, assessment and demonstration as well as de-rating analysis, Failure Mode Effects and Criticality Analysis (FMECA) and worst-case analysis are carried out by SR groups during various stages of project realisation. These activities provide the basis for project management to take appropriate techno-managerial decisions to ensure that the required reliability goals are met. Extensive test facilities catering to the needs of the space program has been set up. A system for consolidating the experience and expertise gained for issue of standards called product assurance specifications to be used in all ISRO centres has also been established.
NASA Technical Reports Server (NTRS)
Gyekenyesi, John P.; Nemeth, Noel N.
1987-01-01
The SCARE (Structural Ceramics Analysis and Reliability Evaluation) computer program on statistical fast fracture reliability analysis with quadratic elements for volume distributed imperfections is enhanced to include the use of linear finite elements and the capability of designing against concurrent surface flaw induced ceramic component failure. The SCARE code is presently coupled as a postprocessor to the MSC/NASTRAN general purpose, finite element analysis program. The improved version now includes the Weibull and Batdorf statistical failure theories for both surface and volume flaw based reliability analysis. The program uses the two-parameter Weibull fracture strength cumulative failure probability distribution model with the principle of independent action for poly-axial stress states, and Batdorf's shear-sensitive as well as shear-insensitive statistical theories. The shear-sensitive surface crack configurations include the Griffith crack and Griffith notch geometries, using the total critical coplanar strain energy release rate criterion to predict mixed-mode fracture. Weibull material parameters based on both surface and volume flaw induced fracture can also be calculated from modulus of rupture bar tests, using the least squares method with known specimen geometry and grouped fracture data. The statistical fast fracture theories for surface flaw induced failure, along with selected input and output formats and options, are summarized. An example problem to demonstrate various features of the program is included.
FY11 Facility Assessment Study for Aeronautics Test Program
NASA Technical Reports Server (NTRS)
Loboda, John A.; Sydnor, George H.
2013-01-01
This paper presents the approach and results for the Aeronautics Test Program (ATP) FY11 Facility Assessment Project. ATP commissioned assessments in FY07 and FY11 to aid in the understanding of the current condition and reliability of its facilities and their ability to meet current and future (five year horizon) test requirements. The principle output of the assessment was a database of facility unique, prioritized investments projects with budgetary cost estimates. This database was also used to identify trends for the condition of facility systems.
Software development predictors, error analysis, reliability models and software metric analysis
NASA Technical Reports Server (NTRS)
Basili, Victor
1983-01-01
The use of dynamic characteristics as predictors for software development was studied. It was found that there are some significant factors that could be useful as predictors. From a study on software errors and complexity, it was shown that meaningful results can be obtained which allow insight into software traits and the environment in which it is developed. Reliability models were studied. The research included the field of program testing because the validity of some reliability models depends on the answers to some unanswered questions about testing. In studying software metrics, data collected from seven software engineering laboratory (FORTRAN) projects were examined and three effort reporting accuracy checks were applied to demonstrate the need to validate a data base. Results are discussed.
High Definition Sounding System Test and Integration with NASA Atmospheric Science Program Aircraft
2013-09-30
of the High Definition Sounding System (HDSS) on NASA high altitude Airborne Science Program platforms, specifically the NASA P-3 and NASA WB-57. When...demonstrate the system reliability in a Global Hawk’s 62000’ altitude regime of thin air and very cold temperatures. APPROACH: Mission Profile One or more WB...57 test flights will prove airworthiness and verify the High Definition Sounding System (HDSS) is safe and functional at high altitudes , essentially
Capacitance discharge system for ignition of Single Bridge Apollo Standard Initiators (SBASI)
NASA Technical Reports Server (NTRS)
Ward, R. D.
1974-01-01
The design support data developed during the single bridge Apollo standard initiator (SBASI) program are presented. A circuit was designed and bread-board tested to verify operational capabilities of the circuit. Test data, design criteria, weight, and reliability trade-off considerations, and final design recommendations are reported.
Qtracer Program for Tracer-Breakthrough Curve Analysis for Karst and Fractured-Rock Aquifers (2000)
Tracer tests are generally regarded as being the most reliable and efficient means of gathering subsurface hydraulic information. This is true for all types of aquifers, but especially so for karst and fractured-rock aquifers. Qualitative tracing tests have been conventionally em...
McKay, E
2000-01-01
An innovative research program was devised to investigate the interactive effect of instructional strategies enhanced with text-plus-textual metaphors or text-plus-graphical metaphors, and cognitive style on the acquisition of programming concepts. The Cognitive Styles Analysis (CSA) program (Riding,1991) was used to establish the participants' cognitive style. The QUEST Interactive Test Analysis System (Adams and Khoo,1996) provided the cognitive performance measuring tool, which ensured an absence of error measurement in the programming knowledge testing instruments. Therefore, reliability of the instrumentation was assured through the calibration techniques utilized by the QUEST estimate; providing predictability of the research design. A means analysis of the QUEST data, using the Cohen (1977) approach to size effect and statistical power further quantified the significance of the findings. The experimental methodology adopted for this research links the disciplines of instructional science, cognitive psychology, and objective measurement to provide reliable mechanisms for beneficial use in the evaluation of cognitive performance by the education, training and development sectors. Furthermore, the research outcomes will be of interest to educators, cognitive psychologists, communications engineers, and computer scientists specializing in computer-human interactions.
NASA Technical Reports Server (NTRS)
Gyekenyesi, J. P.
1985-01-01
A computer program was developed for calculating the statistical fast fracture reliability and failure probability of ceramic components. The program includes the two-parameter Weibull material fracture strength distribution model, using the principle of independent action for polyaxial stress states and Batdorf's shear-sensitive as well as shear-insensitive crack theories, all for volume distributed flaws in macroscopically isotropic solids. Both penny-shaped cracks and Griffith cracks are included in the Batdorf shear-sensitive crack response calculations, using Griffith's maximum tensile stress or critical coplanar strain energy release rate criteria to predict mixed mode fracture. Weibull material parameters can also be calculated from modulus of rupture bar tests, using the least squares method with known specimen geometry and fracture data. The reliability prediction analysis uses MSC/NASTRAN stress, temperature and volume output, obtained from the use of three-dimensional, quadratic, isoparametric, or axisymmetric finite elements. The statistical fast fracture theories employed, along with selected input and output formats and options, are summarized. An example problem to demonstrate various features of the program is included.
Testing of Twin Linear Aerospike XRS-2200 Engine
NASA Technical Reports Server (NTRS)
2001-01-01
The test of twin Linear Aerospike XRS-2200 engines, originally built for the X-33 program, was performed on August 6, 2001 at NASA's Sternis Space Center, Mississippi. The engines were fired for the planned 90 seconds and reached a planned maximum power of 85 percent. NASA's Second Generation Reusable Launch Vehicle Program , also known as the Space Launch Initiative (SLI), is making advances in propulsion technology with this third and final successful engine hot fire, designed to test electro-mechanical actuators. Information learned from this hot fire test series about new electro-mechanical actuator technology, which controls the flow of propellants in rocket engines, could provide key advancements for the propulsion systems for future spacecraft. The Second Generation Reusable Launch Vehicle Program, led by NASA's Marshall Space Flight Center in Huntsville, Alabama, is a technology development program designed to increase safety and reliability while reducing costs for space travel. The X-33 program was cancelled in March 2001.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Puskar, Joseph David; Quintana, Michael A.; Sorensen, Neil Robert
A program is underway at Sandia National Laboratories to predict long-term reliability of photovoltaic (PV) systems. The vehicle for the reliability predictions is a Reliability Block Diagram (RBD), which models system behavior. Because this model is based mainly on field failure and repair times, it can be used to predict current reliability, but it cannot currently be used to accurately predict lifetime. In order to be truly predictive, physics-informed degradation processes and failure mechanisms need to be included in the model. This paper describes accelerated life testing of metal foil tapes used in thin-film PV modules, and how tape jointmore » degradation, a possible failure mode, can be incorporated into the model.« less
Self-audit of lockout/tagout in manufacturing workplaces: A pilot study.
Yamin, Samuel C; Parker, David L; Xi, Min; Stanley, Rodney
2017-05-01
Occupational health and safety (OHS) self-auditing is a common practice in industrial workplaces. However, few audit instruments have been tested for inter-rater reliability and accuracy. A lockout/tagout (LOTO) self-audit checklist was developed for use in manufacturing enterprises. It was tested for inter-rater reliability and accuracy using responses of business self-auditors and external auditors. Inter-rater reliability at ten businesses was excellent (κ = 0.84). Business self-auditors had high (100%) accuracy in identifying elements of LOTO practice that were present as well those that were absent (81% accuracy). Reliability and accuracy increased further when problematic checklist questions were removed from the analysis. Results indicate that the LOTO self-audit checklist would be useful in manufacturing firms' efforts to assess and improve their LOTO programs. In addition, a reliable self-audit instrument removes the need for external auditors to visit worksites, thereby expanding capacity for outreach and intervention while minimizing costs. © 2017 Wiley Periodicals, Inc.
Schache, Margaret B; McClelland, Jodie A; Webster, Kate E
2016-01-01
To investigate the test-retest reliability of measuring hip abductor strength in patients with total knee arthroplasty (TKA) using a hand-held dynamometer (HHD) with two different types of resistance: belt and manual resistance. Test-retest reliability of 30 subjects (17 female, 13 male, 71.9 ± 7.4 years old), 9.2 ± 2.7 days post TKA was measured using belt and therapist resistance. Retest reliability was calculated with intra-class coefficients (ICC3,1) and 95% confidence intervals (CI) for both the group average and the individual scores. A paired t-test assessed whether a difference existed between the belt and therapist methods of resistance. ICCs were 0.82 and 0.80 for the belt and therapist resisted methods, respectively. Hip abductor strength increases of 8 N (14%) for belt resisted and 14 N (17%) for therapist resisted measurements of the group average exceeded the 95% CI and may represent real change. For individuals, hip abductor strength increases of 33 N (72%) (belt resisted) and 57 N (79%) (therapist resisted) could be interpreted as real change. Hip abductor strength can be reliably measured using HHD in the clinical setting with the described protocol. Belt resistance demonstrated slightly higher test-retest reliability. Reliable measurement of hip abductor muscle strength in patients with TKA is important to ensure deficiencies are addressed in rehabilitation programs and function is maximized. Hip abductor strength can be reliably measured with a hand-held dynamometer in the clinical setting using manual or belt resistance.
Galileo battery testing and the impact of test automation
NASA Technical Reports Server (NTRS)
Pertuch, W. T.; Dils, C. T.
1985-01-01
Test complexity, changes of test specifications, and the demand for tight control of tests led to the development of automated testing used for Galileo and other projects. The use of standardized interfacing, i.e., IEEE-488, with desktop computers and test instruments, resulted in greater reliability, repeatability, and accuracy of both control and data reporting. Increased flexibility of test programming has reduced costs by permitting a wide spectrum of test requirements at one station rather than many stations.
Evaluation of rail test frequencies using risk analysis
DOT National Transportation Integrated Search
2009-03-03
Several industries now use risk analysis to develop : inspection programs to ensure acceptable mechanical integrity : and reliability. These industries include nuclear and electric : power generation, oil refining, gas processing, onshore and : offsh...
Program For Evaluation Of Reliability Of Ceramic Parts
NASA Technical Reports Server (NTRS)
Nemeth, N.; Janosik, L. A.; Gyekenyesi, J. P.; Powers, Lynn M.
1996-01-01
CARES/LIFE predicts probability of failure of monolithic ceramic component as function of service time. Assesses risk that component fractures prematurely as result of subcritical crack growth (SCG). Effect of proof testing of components prior to service also considered. Coupled to such commercially available finite-element programs as ANSYS, ABAQUS, MARC, MSC/NASTRAN, and COSMOS/M. Also retains all capabilities of previous CARES code, which includes estimation of fast-fracture component reliability and Weibull parameters from inert strength (without SCG contributing to failure) specimen data. Estimates parameters that characterize SCG from specimen data as well. Written in ANSI FORTRAN 77 to be machine-independent. Program runs on any computer in which sufficient addressable memory (at least 8MB) and FORTRAN 77 compiler available. For IBM-compatible personal computer with minimum 640K memory, limited program available (CARES/PC, COSMIC number LEW-15248).
Power Quality and Reliability Project
NASA Technical Reports Server (NTRS)
Attia, John O.
2001-01-01
One area where universities and industry can link is in the area of power systems reliability and quality - key concepts in the commercial, industrial and public sector engineering environments. Prairie View A&M University (PVAMU) has established a collaborative relationship with the University of'Texas at Arlington (UTA), NASA/Johnson Space Center (JSC), and EP&C Engineering and Technology Group (EP&C) a small disadvantage business that specializes in power quality and engineering services. The primary goal of this collaboration is to facilitate the development and implementation of a Strategic Integrated power/Systems Reliability and Curriculum Enhancement Program. The objectives of first phase of this work are: (a) to develop a course in power quality and reliability, (b) to use the campus of Prairie View A&M University as a laboratory for the study of systems reliability and quality issues, (c) to provide students with NASA/EPC shadowing and Internship experience. In this work, a course, titled "Reliability Analysis of Electrical Facilities" was developed and taught for two semesters. About thirty seven has benefited directly from this course. A laboratory accompanying the course was also developed. Four facilities at Prairie View A&M University were surveyed. Some tests that were performed are (i) earth-ground testing, (ii) voltage, amperage and harmonics of various panels in the buildings, (iii) checking the wire sizes to see if they were the right size for the load that they were carrying, (iv) vibration tests to test the status of the engines or chillers and water pumps, (v) infrared testing to the test arcing or misfiring of electrical or mechanical systems.
CROSSER - CUMULATIVE BINOMIAL PROGRAMS
NASA Technical Reports Server (NTRS)
Bowerman, P. N.
1994-01-01
The cumulative binomial program, CROSSER, is one of a set of three programs which calculate cumulative binomial probability distributions for arbitrary inputs. The three programs, CROSSER, CUMBIN (NPO-17555), and NEWTONP (NPO-17556), can be used independently of one another. CROSSER can be used by statisticians and users of statistical procedures, test planners, designers, and numerical analysts. The program has been used for reliability/availability calculations. CROSSER calculates the point at which the reliability of a k-out-of-n system equals the common reliability of the n components. It is designed to work well with all integer values 0 < k <= n. To run the program, the user simply runs the executable version and inputs the information requested by the program. The program is not designed to weed out incorrect inputs, so the user must take care to make sure the inputs are correct. Once all input has been entered, the program calculates and lists the result. It also lists the number of iterations of Newton's method required to calculate the answer within the given error. The CROSSER program is written in C. It was developed on an IBM AT with a numeric co-processor using Microsoft C 5.0. Because the source code is written using standard C structures and functions, it should compile correctly with most C compilers. The program format is interactive. It has been implemented under DOS 3.2 and has a memory requirement of 26K. CROSSER was developed in 1988.
NASA Astrophysics Data System (ADS)
Launch vehicle propulsion system reliability considerations during the design and verification processes are discussed. The tools available for predicting and minimizing anomalies or failure modes are described and objectives for validating advanced launch system propulsion reliability are listed. Methods for ensuring vehicle/propulsion system interface reliability are examined and improvements in the propulsion system development process are suggested to improve reliability in launch operations. Also, possible approaches to streamline the specification and procurement process are given. It is suggested that government and industry should define reliability program requirements and manage production and operations activities in a manner that provides control over reliability drivers. Also, it is recommended that sufficient funds should be invested in design, development, test, and evaluation processes to ensure that reliability is not inappropriately subordinated to other management considerations.
Ultra Reliable Closed Loop Life Support for Long Space Missions
NASA Technical Reports Server (NTRS)
Jones, Harry W.; Ewert, Michael K.
2010-01-01
Spacecraft human life support systems can achieve ultra reliability by providing sufficient spares to replace all failed components. The additional mass of spares for ultra reliability is approximately equal to the original system mass, provided that the original system reliability is not too low. Acceptable reliability can be achieved for the Space Shuttle and Space Station by preventive maintenance and by replacing failed units. However, on-demand maintenance and repair requires a logistics supply chain in place to provide the needed spares. In contrast, a Mars or other long space mission must take along all the needed spares, since resupply is not possible. Long missions must achieve ultra reliability, a very low failure rate per hour, since they will take years rather than weeks and cannot be cut short if a failure occurs. Also, distant missions have a much higher mass launch cost per kilogram than near-Earth missions. Achieving ultra reliable spacecraft life support systems with acceptable mass will require a well-planned and extensive development effort. Analysis must determine the reliability requirement and allocate it to subsystems and components. Ultra reliability requires reducing the intrinsic failure causes, providing spares to replace failed components and having "graceful" failure modes. Technologies, components, and materials must be selected and designed for high reliability. Long duration testing is needed to confirm very low failure rates. Systems design should segregate the failure causes in the smallest, most easily replaceable parts. The system must be designed, developed, integrated, and tested with system reliability in mind. Maintenance and reparability of failed units must not add to the probability of failure. The overall system must be tested sufficiently to identify any design errors. A program to develop ultra reliable space life support systems with acceptable mass should start soon since it must be a long term effort.
Developing Ultra Reliable Life Support for the Moon and Mars
NASA Technical Reports Server (NTRS)
Jones, Harry W.
2009-01-01
Recycling life support systems can achieve ultra reliability by using spares to replace failed components. The added mass for spares is approximately equal to the original system mass, provided the original system reliability is not very low. Acceptable reliability can be achieved for the space shuttle and space station by preventive maintenance and by replacing failed units, However, this maintenance and repair depends on a logistics supply chain that provides the needed spares. The Mars mission must take all the needed spares at launch. The Mars mission also must achieve ultra reliability, a very low failure rate per hour, since it requires years rather than weeks and cannot be cut short if a failure occurs. Also, the Mars mission has a much higher mass launch cost per kilogram than shuttle or station. Achieving ultra reliable space life support with acceptable mass will require a well-planned and extensive development effort. Analysis must define the reliability requirement and allocate it to subsystems and components. Technologies, components, and materials must be designed and selected for high reliability. Extensive testing is needed to ascertain very low failure rates. Systems design should segregate the failure causes in the smallest, most easily replaceable parts. The systems must be designed, produced, integrated, and tested without impairing system reliability. Maintenance and failed unit replacement should not introduce any additional probability of failure. The overall system must be tested sufficiently to identify any design errors. A program to develop ultra reliable space life support systems with acceptable mass must start soon if it is to produce timely results for the moon and Mars.
NASA Technical Reports Server (NTRS)
Myers, William; Winter, Steve
2006-01-01
The General Electric Reliable and Affordable Controls effort under the NASA Advanced Subsonic Technology (AST) Program has designed, fabricated, and tested advanced controls hardware and software to reduce emissions and improve engine safety and reliability. The original effort consisted of four elements: 1) a Hydraulic Multiplexer; 2) Active Combustor Control; 3) a Variable Displacement Vane Pump (VDVP); and 4) Intelligent Engine Control. The VDVP and Intelligent Engine Control elements were cancelled due to funding constraints and are reported here only to the state they progressed. The Hydraulic Multiplexing element developed and tested a prototype which improves reliability by combining the functionality of up to 16 solenoids and servo-valves into one component with a single electrically powered force motor. The Active Combustor Control element developed intelligent staging and control strategies for low emission combustors. This included development and tests of a Controlled Pressure Fuel Nozzle for fuel sequencing, a Fuel Multiplexer for individual fuel cup metering, and model-based control logic. Both the Hydraulic Multiplexer and Controlled Pressure Fuel Nozzle system were cleared for engine test. The Fuel Multiplexer was cleared for combustor rig test which must be followed by an engine test to achieve full maturation.
Simulation-Based Training for Colonoscopy
Preisler, Louise; Svendsen, Morten Bo Søndergaard; Nerup, Nikolaj; Svendsen, Lars Bo; Konge, Lars
2015-01-01
Abstract The aim of this study was to create simulation-based tests with credible pass/fail standards for 2 different fidelities of colonoscopy models. Only competent practitioners should perform colonoscopy. Reliable and valid simulation-based tests could be used to establish basic competency in colonoscopy before practicing on patients. Twenty-five physicians (10 consultants with endoscopic experience and 15 fellows with very little endoscopic experience) were tested on 2 different simulator models: a virtual-reality simulator and a physical model. Tests were repeated twice on each simulator model. Metrics with discriminatory ability were identified for both modalities and reliability was determined. The contrasting-groups method was used to create pass/fail standards and the consequences of these were explored. The consultants significantly performed faster and scored higher than the fellows on both the models (P < 0.001). Reliability analysis showed Cronbach α = 0.80 and 0.87 for the virtual-reality and the physical model, respectively. The established pass/fail standards failed one of the consultants (virtual-reality simulator) and allowed one fellow to pass (physical model). The 2 tested simulations-based modalities provided reliable and valid assessments of competence in colonoscopy and credible pass/fail standards were established for both the tests. We propose to use these standards in simulation-based training programs before proceeding to supervised training on patients. PMID:25634177
Report on phase 1 of the Microprocessor Seminar. [and associated large scale integration
NASA Technical Reports Server (NTRS)
1977-01-01
Proceedings of a seminar on microprocessors and associated large scale integrated (LSI) circuits are presented. The potential for commonality of device requirements, candidate processes and mechanisms for qualifying candidate LSI technologies for high reliability applications, and specifications for testing and testability were among the topics discussed. Various programs and tentative plans of the participating organizations in the development of high reliability LSI circuits are given.
Hauge, Cindy Horst; Jacobs-Knight, Jacque; Jensen, Jamie L; Burgess, Katherine M; Puumala, Susan E; Wilton, Georgiana; Hanson, Jessica D
2015-06-01
The purpose of this study was to use a mixed-methods approach to determine the validity and reliability of measurements used within an alcohol-exposed pregnancy prevention program for American Indian women. To develop validity, content experts provided input into the survey measures, and a "think aloud" methodology was conducted with 23 American Indian women. After revising the measurements based on this input, a test-retest was conducted with 79 American Indian women who were randomized to complete either the original measurements or the new, modified measurements. The test-retest revealed that some of the questions performed better for the modified version, whereas others appeared to be more reliable for the original version. The mixed-methods approach was a useful methodology for gathering feedback on survey measurements from American Indian participants and in indicating specific survey questions that needed to be modified for this population. © The Author(s) 2015.
Grooten, Wilhelmus Johannes Andreas; Sandberg, Lisa; Ressman, John; Diamantoglou, Nicolas; Johansson, Elin; Rasmussen-Barr, Eva
2018-01-08
Clinical examinations are subjective and often show a low validity and reliability. Objective and highly reliable quantitative assessments are available in laboratory settings using 3D motion analysis, but these systems are too expensive to use for simple clinical examinations. Qinematic™ is an interactive movement analyses system based on the Kinect camera and is an easy-to-use clinical measurement system for assessing posture, balance and side-bending. The aim of the study was to test the test-retest the reliability and construct validity of Qinematic™ in a healthy population, and to calculate the minimal clinical differences for the variables of interest. A further aim was to identify the discriminative validity of Qinematic™ in people with low-back pain (LBP). We performed a test-retest reliability study (n = 37) with around 1 week between the occasions, a construct validity study (n = 30) in which Qinematic™ was tested against a 3D motion capture system, and a discriminative validity study, in which a group of people with LBP (n = 20) was compared to healthy controls (n = 17). We tested a large range of psychometric properties of 18 variables in three sections: posture (head and pelvic position, weight distribution), balance (sway area and velocity in single- and double-leg stance), and side-bending. The majority of the variables in the posture and balance sections, showed poor/fair reliability (ICC < 0.4) and poor/fair validity (Spearman <0.4), with significant differences between occasions, between Qinematic™ and the 3D-motion capture system. In the clinical study, Qinematic™ did not differ between people with LPB and healthy for these variables. For one variable, side-bending to the left, there was excellent reliability (ICC =0.898), excellent validity (r = 0.943), and Qinematic™ could differentiate between LPB and healthy individuals (p = 0.012). This paper shows that a novel software program (Qinematic™) based on the Kinect camera for measuring balance, posture and side-bending has poor psychometric properties, indicating that the variables on balance and posture should not be used for monitoring individual changes over time or in research. Future research on the dynamic tasks of Qinematic™ is warranted.
NASA Technical Reports Server (NTRS)
Miller, James; Leggett, Jay; Kramer-White, Julie
2008-01-01
A team directed by the NASA Engineering and Safety Center (NESC) collected methodologies for how best to develop safe and reliable human rated systems and how to identify the drivers that provide the basis for assessing safety and reliability. The team also identified techniques, methodologies, and best practices to assure that NASA can develop safe and reliable human rated systems. The results are drawn from a wide variety of resources, from experts involved with the space program since its inception to the best-practices espoused in contemporary engineering doctrine. This report focuses on safety and reliability considerations and does not duplicate or update any existing references. Neither does it intend to replace existing standards and policy.
Development and Testing of a High Stability Engine Control (HISTEC) System
NASA Technical Reports Server (NTRS)
Orme, John S.; DeLaat, John C.; Southwick, Robert D.; Gallops, George W.; Doane, Paul M.
1998-01-01
Flight tests were recently completed to demonstrate an inlet-distortion-tolerant engine control system. These flight tests were part of NASA's High Stability Engine Control (HISTEC) program. The objective of the HISTEC program was to design, develop, and flight demonstrate an advanced integrated engine control system that uses measurement-based, real-time estimates of inlet airflow distortion to enhance engine stability. With improved stability and tolerance of inlet airflow distortion, future engine designs may benefit from a reduction in design stall-margin requirements and enhanced reliability, with a corresponding increase in performance and decrease in fuel consumption. This paper describes the HISTEC methodology, presents an aircraft test bed description (including HISTEC-specific modifications) and verification and validation ground tests. Additionally, flight test safety considerations, test plan and technique design and approach, and flight operations are addressed. Some illustrative results are presented to demonstrate the type of analysis and results produced from the flight test program.
Roland: A Case for or Against NATO Standardization?
1980-05-01
with often competing, even opposing, objectives in testing, financial auditing , cost estimating, reliability, value engineering, maintenance, training...supposedly mature system. Multilocation tests, early in the program when test beds and spare parts availability would be at a minimum, would require...Similar institutionalized conflicts resided in the audit community, which, under the Armed Services Procurement Regulation, was required to audit and
NASA EEE Parts and Advanced Interconnect Program (AIP)
NASA Technical Reports Server (NTRS)
Gindorf, T.; Garrison, A.
1996-01-01
none given From Program Objectives: I. Accelerate the readiness of new technologies through development of validation, assessment and test method/tools II. Provide NASA Projects infusion paths for emerging technologies III. Provide NASA Projects technology selection, application and validation guidelines for harware and processes IV. Disseminate quality assurance, reliability, validation, tools and availability information to the NASA community.
Development and exploratory analysis of the Neurorehabilitation Program Styles Survey.
McCorkel, Beth A; Glueckauf, Robert L; Ecklund-Johnson, Eric P; Tomusk, Allison B; Trexler, Lance E; Diller, Leonard
2003-01-01
To develop a survey instrument that assesses implementation of key components of outpatient neurorehabilitation programs and test the capacity of this instrument to differentiate between rehabilitation approaches. The Neurorehabilitation Program Styles Survey (NPSS) was administered to 18 outpatient facilities: 10 specialized and 8 discipline-specific outpatient neurorehabilitation programs. Scores were compared between types of programs using independent samples t tests. The NPSS showed good reliability and contrasted groups validity, significantly differentiating between types of programs. The NPSS holds considerable promise as a tool for distinguishing among different types of brain injury programs, and for assessing the differential effectiveness of specialized versus discipline-specific outpatient brain rehabilitation programs. Future research on the NPSS will assess the stability of the instrument over time, its content validity, and capacity to differentiate the full continuum of neurorehabilitation programs.
NASA Technical Reports Server (NTRS)
Nemeth, Noel N.
2002-01-01
Brittle materials are being used, or considered, for a wide variety of high tech applications that operate in harsh environments, including static and rotating turbine parts. thermal protection systems, dental prosthetics, fuel cells, oxygen transport membranes, radomes, and MEMS. Designing components to sustain repeated load without fracturing while using the minimum amount of material requires the use of a probabilistic design methodology. The CARES/Life code provides a general-purpose analysis tool that predicts the probability of failure of a ceramic component as a function of its time in service. For this presentation an interview of the CARES/Life program will be provided. Emphasis will be placed on describing the latest enhancements to the code for reliability analysis with time varying loads and temperatures (fully transient reliability analysis). Also, early efforts in investigating the validity of using Weibull statistics, the basis of the CARES/Life program, to characterize the strength of MEMS structures will be described as as well as the version of CARES/Life for MEMS (CARES/MEMS) being prepared which incorporates single crystal and edge flaw reliability analysis capability. It is hoped this talk will open a dialog for potential collaboration in the area of MEMS testing and life prediction.
Object-oriented fault tree evaluation program for quantitative analyses
NASA Technical Reports Server (NTRS)
Patterson-Hine, F. A.; Koen, B. V.
1988-01-01
Object-oriented programming can be combined with fault free techniques to give a significantly improved environment for evaluating the safety and reliability of large complex systems for space missions. Deep knowledge about system components and interactions, available from reliability studies and other sources, can be described using objects that make up a knowledge base. This knowledge base can be interrogated throughout the design process, during system testing, and during operation, and can be easily modified to reflect design changes in order to maintain a consistent information source. An object-oriented environment for reliability assessment has been developed on a Texas Instrument (TI) Explorer LISP workstation. The program, which directly evaluates system fault trees, utilizes the object-oriented extension to LISP called Flavors that is available on the Explorer. The object representation of a fault tree facilitates the storage and retrieval of information associated with each event in the tree, including tree structural information and intermediate results obtained during the tree reduction process. Reliability data associated with each basic event are stored in the fault tree objects. The object-oriented environment on the Explorer also includes a graphical tree editor which was modified to display and edit the fault trees.
DOE Office of Scientific and Technical Information (OSTI.GOV)
LukyanenkoMD, Victor; Eisele, Gerhard R; Coates, Cameron W
2010-01-01
Through a cooperative effort between the U. S. Department of Energy and the Russian Federation (RF) Ministry of Defense (MOD) a Personnel Reliability Program (PRP) for the nuclear handlers within the RF MOD has been implemented. A key element in the RF MOD PRP is the detection and confirmation of narcotic use in subject military and civilian personnel. This paper describes the process of narcotics screening and testing in the RF MOD and explains the confirmation process once screening has shown a positive result. Issues of laboratory certification, employee certification, employee training, sample chain-of-custody, and equipment needs will be addressed.
Affordable MMICs for Air Force systems
NASA Astrophysics Data System (ADS)
Kemerley, Robert T.; Fayette, Daniel F.
1991-05-01
The paper deals with a program directed at demonstrating affordable MMIC chips - the microwave/mm-wave monolithic integrated circuit (MIMIC) program. Focus is placed on experiments involving the growth and characterization of III-V materials, and the design, fabrication, and evaluation of ICs in the 1 to 60 GHz frequency range, as well as efforts related to the reliability testing, failure analysis, and generation of qualified manufacture's list procedures for GaAs MMICs and modules. Attributes associated with GaAs-technology devices, quality, reliability, and performance in select environments are discussed, including the dependence of these structures over temperature ranges, electrostatic discharge sensitivity, and susceptibility to environmental stresses.
Joint Air-to-Surface Standoff Missile (JASSM)
2015-12-01
6.1.3) All Ops All Ops Joint Critical Ops All Ops All Ops Missile Reliability (KSA) (CPD para 6.2.8) 4th Lot .91 4th Lot .91 IOT &E .80 4th Lot .85 IOT &E...the ORD 303-95-III dated January 20, 2004 Change Explanations None Acronyms and Abbreviations IOT &E - Initial Operational Test and Evaluation KSA... Actuator Control Card, Lots 12 and 4 Systems Engineering Program Support/Program Tooling and Test Equipment, and JASSM-ER Standard Data Protocol (DS
Hastedt, Martin; Krumbiegel, Franziska; Gapert, René; Tsokos, Michael; Hartwig, Sven
2013-09-01
Alcohol consumption during pregnancy is a widespread problem and can cause severe fetal damage. As the diagnosis of fetal alcohol syndrome is difficult, the implementation of a reliable marker for alcohol consumption during pregnancy into meconium drug screening programs would be invaluable. A previously published gas chromatography mass spectrometry method for the detection of fatty acid ethyl esters (FAEEs) as alcohol markers in meconium was optimized and newly validated for a sample size of 50 mg. This method was applied to 122 cases from a drug-using population. The meconium samples were also tested for common drugs of abuse. In 73 % of the cases, one or more drugs were found. Twenty percent of the samples tested positive for FAEEs at levels indicating significant alcohol exposure. Consequently, alcohol was found to be the third most frequently abused substance within the study group. This re-validated method provides an increase in testing sensitivity, is reliable and easily applicable as part of a drug screening program. It can be used as a non-invasive tool to detect high alcohol consumption in the last trimester of pregnancy. The introduction of FAEEs testing in meconium screening was found to be of particular use in a drug-using population.
Assessment of NDE Reliability Data
NASA Technical Reports Server (NTRS)
Yee, B. G. W.; Chang, F. H.; Couchman, J. C.; Lemon, G. H.; Packman, P. F.
1976-01-01
Twenty sets of relevant Nondestructive Evaluation (NDE) reliability data have been identified, collected, compiled, and categorized. A criterion for the selection of data for statistical analysis considerations has been formulated. A model to grade the quality and validity of the data sets has been developed. Data input formats, which record the pertinent parameters of the defect/specimen and inspection procedures, have been formulated for each NDE method. A comprehensive computer program has been written to calculate the probability of flaw detection at several confidence levels by the binomial distribution. This program also selects the desired data sets for pooling and tests the statistical pooling criteria before calculating the composite detection reliability. Probability of detection curves at 95 and 50 percent confidence levels have been plotted for individual sets of relevant data as well as for several sets of merged data with common sets of NDE parameters.
NASA Technical Reports Server (NTRS)
Lee, Alice T.; Gunn, Todd; Pham, Tuan; Ricaldi, Ron
1994-01-01
This handbook documents the three software analysis processes the Space Station Software Analysis team uses to assess space station software, including their backgrounds, theories, tools, and analysis procedures. Potential applications of these analysis results are also presented. The first section describes how software complexity analysis provides quantitative information on code, such as code structure and risk areas, throughout the software life cycle. Software complexity analysis allows an analyst to understand the software structure, identify critical software components, assess risk areas within a software system, identify testing deficiencies, and recommend program improvements. Performing this type of analysis during the early design phases of software development can positively affect the process, and may prevent later, much larger, difficulties. The second section describes how software reliability estimation and prediction analysis, or software reliability, provides a quantitative means to measure the probability of failure-free operation of a computer program, and describes the two tools used by JSC to determine failure rates and design tradeoffs between reliability, costs, performance, and schedule.
Design and implementation of online automatic judging system
NASA Astrophysics Data System (ADS)
Liang, Haohui; Chen, Chaojie; Zhong, Xiuyu; Chen, Yuefeng
2017-06-01
For lower efficiency and poorer reliability in programming training and competition by currently artificial judgment, design an Online Automatic Judging (referred to as OAJ) System. The OAJ system including the sandbox judging side and Web side, realizes functions of automatically compiling and running the tested codes, and generating evaluation scores and corresponding reports. To prevent malicious codes from damaging system, the OAJ system utilizes sandbox, ensuring the safety of the system. The OAJ system uses thread pools to achieve parallel test, and adopt database optimization mechanism, such as horizontal split table, to improve the system performance and resources utilization rate. The test results show that the system has high performance, high reliability, high stability and excellent extensibility.
Aguirrezabal Juaristi, Aizpea; Ferrer Fores, Montse; Marco Navarro, Ester; Mojal García, Sergi; Vilagut Saiz, Gemma; Duarte Oller, Esther
2016-11-18
The Satisfaction Pound Scale is a specific questionnaire to evaluate satisfaction with the rehabilitation program after a stroke. The aim of this study was to adapt this scale to Spanish and to evaluate its metric characteristics. The adaptation included translation and back-translation methods. Metric characteristics were evaluated in 74 patients, all of whom were administered the Satisfaction Pound Scale and the Short Form 36 (SF-36). The statistical model was tested by confirmatory factor analysis (CFA). Reliability was determined through Cronbach alpha coefficient and a test-retest procedure. Construct validity was assessed by means of correlations between the satisfaction scale and the SF-36. Adjustment indicators in the CFA were very good. Reproducibility test showed correlations higher than 0.85, and all correlations between SF-36 dimensions and the satisfaction scale were lower than 0.2, in accordance with the hypotheses raised. The Spanish version of the Satisfaction Pounds Scale is reliable and valid, therefore it is a useful tool to assess satisfaction with the post-stroke rehabilitation program in our area. Copyright © 2016 Elsevier España, S.L.U. All rights reserved.
Assessment Practices of School Psychologists When Identifying Children for SED Classes.
ERIC Educational Resources Information Center
Strelnieks, Maija; Wessel, Joan
This study investigated the procedures used by psychologists in a large midwestern urban area for the initial diagnosis and placement of elementary children with severe emotional disturbance (SED) in educational programs in light of the widespread criticism of the use of projective tests due to the questionable reliability of the tests and…
Measuring the Quality of Inclusive Practices: Findings from the Inclusive Classroom Profile Pilot
ERIC Educational Resources Information Center
Soukakou, Elena P.; Winton, Pam J.; West, Tracey A.; Sideris, John H.; Rucker, Lia M.
2014-01-01
The purpose of this study was to test the reliability and validity of the Inclusive Classroom Profile (ICP), an observation measure designed to assess the quality of classroom practices in inclusive preschool programs. The measure was field tested in 51 inclusive classrooms. Results confirmed and extended previous research findings, providing…
Assessment, development, and testing of glass for blast environments.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Glass, Sarah Jill
2003-06-01
Glass can have lethal effects including fatalities and injuries when it breaks and then flies through the air under blast loading (''the glass problem''). One goal of this program was to assess the glass problem and solutions being pursued to mitigate it. One solution to the problem is the development of new glass technology that allows the strength and fragmentation to be controlled or selected depending on the blast performance specifications. For example the glass could be weak and fail, or it could be strong and survive, but it must perform reliably. Also, once it fails it should produce fragmentsmore » of a controlled size. Under certain circumstances it may be beneficial to have very small fragments, in others it may be beneficial to have large fragments that stay together. The second goal of this program was to evaluate the performance (strength, reliability, and fragmentation) of Engineered Stress Profile (ESP) glass under different loading conditions. These included pseudo-static strength and pressure tests and free-field blast tests. The ultimate goal was to provide engineers and architects with a glass whose behavior under blast loading is less lethal. A near-term benefit is a new approach for improving the reliability of glass and modifying its fracture behavior.« less
Reliability Measure of a Clinical Test: Appreciation of Music in Cochlear Implantees (AMICI)
Cheng, Min-Yu; Spitzer, Jaclyn B.; Shafiro, Valeriy; Sheft, Stanley; Mancuso, Dean
2014-01-01
Purpose The goals of this study were (1) to investigate the reliability of a clinical music perception test, Appreciation of Music in Cochlear Implantees (AMICI), and (2) examine associations between the perception of music and speech. AMICI was developed as a clinical instrument for assessing music perception in persons with cochlear implants (CIs). The test consists of four subtests: (1) music versus environmental noise discrimination, (2) musical instrument identification (closed-set), (3) musical style identification (closed-set), and (4) identification of musical pieces (open-set). To be clinically useful, it is crucial for AMICI to demonstrate high test-retest reliability, so that CI users can be assessed and retested after changes in maps or programming strategies. Research Design Thirteen CI subjects were tested with AMICI for the initial visit and retested again 10–14 days later. Two speech perception tests (consonant-nucleus-consonant [CNC] and Bamford-Kowal-Bench Speech-in-Noise [BKB-SIN]) were also administered. Data Analysis Test-retest reliability and equivalence of the test’s three forms were analyzed using paired t-tests and correlation coefficients, respectively. Correlation analysis was also conducted between results from the music and speech perception tests. Results Results showed no significant difference between test and retest (p > 0.05) with adequate power (0.9) as well as high correlations between the three forms (Forms A and B, r = 0.91; Forms A and C, r = 0.91; Forms B and C, r = 0.95). Correlation analysis showed high correlation between AMICI and BKB-SIN (r = −0.71), and moderate correlation between AMICI and CNC (r = 0.4). Conclusions The study showed AMICI is highly reliable for assessing musical perception in CI users. PMID:24384082
Chemical dependency and drug testing in the workplace.
Osterloh, J D; Becker, C E
1990-01-01
Urine testing for drug use in the workplace is now widespread, with the prevalence of positive drug tests in the work force being 0% to 15%. The prevalence of marijuana use is highest of the illicit drugs being tested. Highly prevalent drugs can be reliably tested. Although it is prudent to rid the workplace of drug use, there is little scientific study on the relationship of drug use and workplace outcomes, such as productivity and safety. Probable-cause testing and preemployment testing are the most common applications. Random testing has been less accepted owing to its higher costs, unresolved legal issues, and predictably poor test reliability. Legal issues have focused on the right to privacy, policy agreements, discrimination, and the lack of due process. The legal cornerstone of a good program is a policy that is planned and agreed on by both labor and management, which serves both as a contract and as a procedure in which expectations and consequences are known. Moreover, NIDA is certifying laboratories doing employee drug testing. Testing methods, when done correctly, are less prone to error than in the past, but screening tests can be defeated by adulterants. Although the incidence of false-positive results is low, such tests are less reliable when the prevalence of drug abuse is also low.
Mandillo, Silvia; Tucci, Valter; Hölter, Sabine M.; Meziane, Hamid; Banchaabouchi, Mumna Al; Kallnik, Magdalena; Lad, Heena V.; Nolan, Patrick M.; Ouagazzal, Abdel-Mouttalib; Coghill, Emma L.; Gale, Karin; Golini, Elisabetta; Jacquot, Sylvie; Krezel, Wojtek; Parker, Andy; Riet, Fabrice; Schneider, Ilka; Marazziti, Daniela; Auwerx, Johan; Brown, Steve D. M.; Chambon, Pierre; Rosenthal, Nadia; Tocchini-Valentini, Glauco; Wurst, Wolfgang
2008-01-01
Establishing standard operating procedures (SOPs) as tools for the analysis of behavioral phenotypes is fundamental to mouse functional genomics. It is essential that the tests designed provide reliable measures of the process under investigation but most importantly that these are reproducible across both time and laboratories. For this reason, we devised and tested a set of SOPs to investigate mouse behavior. Five research centers were involved across France, Germany, Italy, and the UK in this study, as part of the EUMORPHIA program. All the procedures underwent a cross-validation experimental study to investigate the robustness of the designed protocols. Four inbred reference strains (C57BL/6J, C3HeB/FeJ, BALB/cByJ, 129S2/SvPas), reflecting their use as common background strains in mutagenesis programs, were analyzed to validate these tests. We demonstrate that the operating procedures employed, which includes open field, SHIRPA, grip-strength, rotarod, Y-maze, prepulse inhibition of acoustic startle response, and tail flick tests, generated reproducible results between laboratories for a number of the test output parameters. However, we also identified several uncontrolled variables that constitute confounding factors in behavioral phenotyping. The EUMORPHIA SOPs described here are an important start-point for the ongoing development of increasingly robust phenotyping platforms and their application in large-scale, multicentre mouse phenotyping programs. PMID:18505770
Oremus, Mark; Oremus, Carolina; Hall, Geoffrey B C; McKinnon, Margaret C
2012-01-01
Quality assessment of included studies is an important component of systematic reviews. The authors investigated inter-rater and test-retest reliability for quality assessments conducted by inexperienced student raters. Student raters received a training session on quality assessment using the Jadad Scale for randomised controlled trials and the Newcastle-Ottawa Scale (NOS) for observational studies. Raters were randomly assigned into five pairs and they each independently rated the quality of 13-20 articles. These articles were drawn from a pool of 78 papers examining cognitive impairment following electroconvulsive therapy to treat major depressive disorder. The articles were randomly distributed to the raters. Two months later, each rater re-assessed the quality of half of their assigned articles. McMaster Integrative Neuroscience Discovery and Study Program. 10 students taking McMaster Integrative Neuroscience Discovery and Study Program courses. The authors measured inter-rater reliability using κ and the intraclass correlation coefficient type 2,1 or ICC(2,1). The authors measured test-retest reliability using ICC(2,1). Inter-rater reliability varied by scale question. For the six-item Jadad Scale, question-specific κs ranged from 0.13 (95% CI -0.11 to 0.37) to 0.56 (95% CI 0.29 to 0.83). The ranges were -0.14 (95% CI -0.28 to 0.00) to 0.39 (95% CI -0.02 to 0.81) for the NOS cohort and -0.20 (95% CI -0.49 to 0.09) to 1.00 (95% CI 1.00 to 1.00) for the NOS case-control. For overall scores on the six-item Jadad Scale, ICC(2,1)s for inter-rater and test-retest reliability (accounting for systematic differences between raters) were 0.32 (95% CI 0.08 to 0.52) and 0.55 (95% CI 0.41 to 0.67), respectively. Corresponding ICC(2,1)s for the NOS cohort were -0.19 (95% CI -0.67 to 0.35) and 0.62 (95% CI 0.25 to 0.83), and for the NOS case-control, the ICC(2,1)s were 0.46 (95% CI -0.13 to 0.92) and 0.83 (95% CI 0.48 to 0.95). Inter-rater reliability was generally poor to fair and test-retest reliability was fair to excellent. A pilot rating phase following rater training may be one way to improve agreement.
Ceramics Analysis and Reliability Evaluation of Structures (CARES). Users and programmers manual
NASA Technical Reports Server (NTRS)
Nemeth, Noel N.; Manderscheid, Jane M.; Gyekenyesi, John P.
1990-01-01
This manual describes how to use the Ceramics Analysis and Reliability Evaluation of Structures (CARES) computer program. The primary function of the code is to calculate the fast fracture reliability or failure probability of macroscopically isotropic ceramic components. These components may be subjected to complex thermomechanical loadings, such as those found in heat engine applications. The program uses results from MSC/NASTRAN or ANSYS finite element analysis programs to evaluate component reliability due to inherent surface and/or volume type flaws. CARES utilizes the Batdorf model and the two-parameter Weibull cumulative distribution function to describe the effect of multiaxial stress states on material strength. The principle of independent action (PIA) and the Weibull normal stress averaging models are also included. Weibull material strength parameters, the Batdorf crack density coefficient, and other related statistical quantities are estimated from four-point bend bar or unifrom uniaxial tensile specimen fracture strength data. Parameter estimation can be performed for single or multiple failure modes by using the least-square analysis or the maximum likelihood method. Kolmogorov-Smirnov and Anderson-Darling goodness-of-fit tests, ninety percent confidence intervals on the Weibull parameters, and Kanofsky-Srinivasan ninety percent confidence band values are also provided. The probabilistic fast-fracture theories used in CARES, along with the input and output for CARES, are described. Example problems to demonstrate various feature of the program are also included. This manual describes the MSC/NASTRAN version of the CARES program.
Chemical dependency and drug testing in the workplace.
Osterloh, J D; Becker, C E
1990-05-01
Urine testing for drug use in the workplace is now widespread, with the prevalence of positive drug tests in the work force being 0% to 15%. The prevalence of marijuana use is highest, and this can be reliably tested. Though it is prudent to rid the workplace of drug use, there is little scientific study on the relationship of drug use and workplace outcomes, such as productivity and safety. Probable-cause testing and preemployment testing are the most common applications. Random testing has been less accepted owing to its higher costs, unresolved legal issues, and predictably poor test reliability. Legal issues have focused on the right to policy, discrimination, and the lack of due process. The legal cornerstone of a good program is a policy that is planned and agreed on by both labor and management, which serves both as a contract and as a procedure in which expectations and consequences are known. The National Institute on Drug Abuse is certifying laboratories doing employee drug testing. Testing methods when done correctly are less prone to error than in the past, but screening tests can be defeated by adulterants. Although the incidence of false-positive results is low, such tests are less reliable when the prevalence of drug abuse is also low.
Operation REDWING. Technical Summary of Military Effects. Programs 1-9
1981-05-15
study chorioretinal burns. The primary objective of the program on effects on aircraft structures was to ascer- tain the reliability of current weapons...other aircraft. In the program of tests on service equipment and studies of electromagnetic effects,I 4k. the emphasis was placed on studying long...range detection of nuclear explosions. An additional objective was the study of the effects of nuclear detonations on the ionosphere and microwave
Electron/proton spectrometer certification documentation analyses
NASA Technical Reports Server (NTRS)
Gleeson, P.
1972-01-01
A compilation of analyses generated during the development of the electron-proton spectrometer for the Skylab program is presented. The data documents the analyses required by the electron-proton spectrometer verification plan. The verification plan was generated to satisfy the ancillary hardware requirements of the Apollo Applications program. The certification of the spectrometer requires that various tests, inspections, and analyses be documented, approved, and accepted by reliability and quality control personnel of the spectrometer development program.
Reliability and validity enhancement: a treatment package for increasing fidelity of self-report.
Bornstein, P H; Hamilton, S B; Miller, R K; Quevillon, R P; Spitzform, M
1977-07-01
This study investigated the effects of reliability and validity "enhancers" on fidelity of self-report data in an analogue therapy situation. Under the guise of a Concentration Skills Training Program, 57 Ss were assigned randomly to one of the following conditions: (a) Reliability Enhancement; (b) Truth Talk; (c) No Comment Control. Results indicated significant differences among groups (p less than .05). In addition, tests of multiple comparisons revealed that Reliability Enhancement was significantly different from Truth Talk in occurrences of unreliability (p less than .05). These findings are discussed in light of the increased reliance on self-report data in behavioral intervention, and recommendations are made for future research.
JPL preferred parts list: Reliable electronic components
NASA Technical Reports Server (NTRS)
Covey, R. E.; Scott, W. R.; Hess, L. M.; Steffy, T. G.; Stott, F. R.
1982-01-01
The JPL Preferred Parts List was prepared to provide a basis for selection of electronic parts for JPL spacecraft programs. Supporting tests for the listed parts were designed to comply with specific spacecraft environmental requirements. The list tabulates the electronic, magnetic, and electromechanical parts applicable to all JPL electronic equipment wherein reliability is a major concern. The parts listed are revelant to equipment supplied by subcontractors as well as fabricated at the laboratory.
Qualification of an evaluated butterfly-packaged DFB laser designed for space applications
NASA Astrophysics Data System (ADS)
Tornow, S.; Stier, C.; Buettner, T.; Laurent, T.; Kneier, M.; Bru, J.; Lien, Y.
2017-11-01
An extended qualification program has proven the quality of a previously evaluated semiconductor laser diode, which is intended to be used in a subsystem for the GAIA mission. We report on results of several reliability tests performed in subgroups. The requirements of the procurement specification with respect to reliability and desired manufacturing processes were confirmed. This is an example for successful collaboration between component supplier, system integrator and payload responsible party.
Measuring cognitive change with ImPACT: the aggregate baseline approach.
Bruce, Jared M; Echemendia, Ruben J; Meeuwisse, Willem; Hutchison, Michael G; Aubry, Mark; Comper, Paul
2017-11-01
The Immediate Post-Concussion Assessment and Cognitive Test (ImPACT) is commonly used to assess baseline and post-injury cognition among athletes in North America. Despite this, several studies have questioned the reliability of ImPACT when given at intervals employed in clinical practice. Poor test-retest reliability reduces test sensitivity to cognitive decline, increasing the likelihood that concussed athletes will be returned to play prematurely. We recently showed that the reliability of ImPACT can be increased when using a new composite structure and the aggregate of two baselines to predict subsequent performance. The purpose of the present study was to confirm our previous findings and determine whether the addition of a third baseline would further increase the test-retest reliability of ImPACT. Data from 97 English speaking professional hockey players who had received at least 4 ImPACT baseline evaluations were extracted from a National Hockey League Concussion Program database. Linear regression was used to determine whether each of the first three testing sessions accounted for unique variance in the fourth testing session. Results confirmed that the aggregate baseline approach improves the psychometric properties of ImPACT, with most indices demonstrating adequate or better test-retest reliability for clinical use. The aggregate baseline approach provides a modest clinical benefit when recent baselines are available - and a more substantial benefit when compared to approaches that obtain baseline measures only once during the course of a multi-year playing career. Pending confirmation in diverse samples, neuropsychologists are encouraged to use the aggregate baseline approach to best quantify cognitive change following sports concussion.
Mathiasen, Ross; Hogrefe, Christopher; Harland, Kari; Peterson, Andrew; Smoot, M Kyle
2018-02-15
The Balance Error Scoring System (BESS) is a commonly used concussion assessment tool. Recent studies have questioned the stability and reliability of baseline BESS scores. The purpose of this longitudinal prospective cohort study is to examine differences in yearly baseline BESS scores in athletes participating on an NCAA Division-I football team. NCAA Division-I freshman football athletes were videotaped performing the BESS test at matriculation and after 1 year of participation in the football program. Twenty-three athletes were enrolled in year 1 of the study, and 25 athletes were enrolled in year 2. Those athletes enrolled in year 1 were again videotaped after year 2 of the study. The paired t-test was used to assess for change in score over time for the firm surface, foam surface, and the cumulative BESS score. Additionally, inter- and intrarater reliability values were calculated. Cumulative errors on the BESS significantly decreased from a mean of 20.3 at baseline to 16.8 after 1 year of participation. The mean number of errors following the second year of participation was 15.0. Inter-rater reliability for the cumulative score ranged from 0.65 to 0.75. Intrarater reliability was 0.81. After 1 year of participation, there is a statistically and clinically significant improvement in BESS scores in an NCAA Division-I football program. Although additional improvement in BESS scores was noted after a second year of participation, it did not reach statistical significance. Football athletes should undergo baseline BESS testing at least yearly if the BESS is to be optimally useful as a diagnostic test for concussion.
Ross, David E; Ochs, Alfred L; Seabaugh, Jan M; Demark, Michael F; Shrader, Carole R; Marwitz, Jennifer H; Havranek, Michael D
2012-01-01
NeuroQuant® is a recently developed, FDA-approved software program for measuring brain MRI volume in clinical settings. The aims of this study were as follows: (1) to examine the test-retest reliability of NeuroQuant®; (2) to test the hypothesis that patients with mild traumatic brain injury (TBI) would have abnormally rapid progressive brain atrophy; and (3) to test the hypothesis that progressive brain atrophy in patients with mild TBI would be associated with vocational outcome. Sixteen patients with mild TBI were compared to 20 normal controls. Vocational outcome was assessed with the Glasgow Outcome Scale-Extended (GOSE) and Disability Rating Scale (DRS). NeuroQuant® showed high test-re-test reliability. Patients had abnormally rapid progressive atrophy in several brain regions and the rate of atrophy was associated with inability to return to work. NeuroQuant®, is a reliable and valid method for assessing the anatomic effects of TBI. Progression of atrophy may continue for years after injury, even in patients with mild TBI.
Reliability assessment of Multichip Module technologies via the Triservice/NASA RELTECH program
NASA Astrophysics Data System (ADS)
Fayette, Daniel F.
1994-10-01
Multichip Module (MCM) packaging/interconnect technologies have seen increased emphasis from both the commercial and military communities as a means of increasing capability and performance while providing a vehicle for reducing cost, power and weight of the end item electronic application. This is accomplished through three basic Multichip module technologies, MCM-L that are laminates, MCM-C that are ceramic type substrates and MCM-D that are deposited substrates (e.g., polymer dielectric with thin film metals). Three types of interconnect structures are also used with these substrates and include, wire bond, Tape Automated Bonds (TAB) and flip chip ball bonds. Application, cost, producibility and reliability are the drivers that will determine which MCM technology will best fit a respective need or requirement. With all the benefits and technologies cited, it would be expected that the use of, or the planned use of, MCM's would be more extensive in both military and commercial applications. However, two significant roadblocks exist to implementation of these new technologies: the absence of reliability data and a single national standard for the procurement of reliable/quality MCM's. To address the preceding issues, the Reliability Technology to Achieve Insertion of Advanced Packaging (RELTECH) program has been established. This program, which began in May 1992, has endeavored to evaluate a cross section of MCM technologies covering all classes of MCM's previously cited. NASA and the Tri-Services (Air Force Rome Laboratory, Naval Surface Warfare Center, Crane IN and Army Research Laboratory) have teamed together with sponsorship from ARPA to evaluate the performance, reliability and producibility of MCM's for both military and commercial usage. This is done in close cooperation with our industry partners whose support is critical to the goals of the program. Several tasks are being performed by the RELTECH program and data from this effort, in conjunction with information from our industry partners as well as discussions with industry organizations (IPC, EIA, ISHM, etc.) are being used to develop the qualification and screening requirements for MCM's. Specific tasks being performed by the RELTECH program include technical assessments, product evaluations, reliability modeling, environmental testing, and failure analysis. This paper will describe the various tasks associated with the RELTECH program, status, progress and a description of the national dual use specification being developed for MCM technologies.
21 CFR 212.61 - What must I do to ensure the stability of my PET drug products through expiry?
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 4 2010-04-01 2010-04-01 false What must I do to ensure the stability of my PET... the stability of my PET drug products through expiry? (a) Stability testing program. You must... PET drug products. The test methods must be reliable, meaningful, and specific. The samples tested for...
Cold Regions - Environmental Testing of Individual Soldier Clothing
2011-10-17
Individual Soldier Clothing 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHORS 5d. PROJECT NUMBER 5e. TASK...This Test Operations Procedure (TOP) provides testing guidelines for individual Soldier cold weather clothing and footwear in a cold regions...Soldier clothing , along with its safety, reliability, durability, and performance when exposed to a cold regions environment. 15. SUBJECT TERMS
Design and Development of the Space Shuttle Tail Service Masts
NASA Technical Reports Server (NTRS)
Dandage, S. R.; Herman, N. A.; Godfrey, S. E.; Uda, R. T.
1977-01-01
The successful launch of a space shuttle vehicle depends on the proper operation of two tail service masts (TSMs). Reliable TSM operation is assured through a comprehensive design, development, and testing program. The results of the concept verification test (CVT) and the resulting impact on prototype TSM design are presented. The design criteria are outlined, and the proposed prototype TSM tests are described.
ERIC Educational Resources Information Center
Bean, Rita M.; And Others
The purpose of a project was to develop and test curriculum-based procedures and measures to monitor and assess the reading and writing progress of adults in a basic education program. The most efficient, reliable, and feasible measure of reading performance from beginning reading level through eighth-grade level was the repeated oral reading…
Accelerated degradation of silicon metallization systems
NASA Technical Reports Server (NTRS)
Lathrop, J. W.
1983-01-01
Clemson University has been engaged for the past five years in a program to determine the reliability attributes of solar cells by means of accelerated test procedures. The cells are electrically measured and visually inspected and then subjected for a period of time to stress in excess of that normally encountered in use, and then they are reinspected. Changes are noted and the process repeated. This testing has thus far involved 23 different unencapsulated cell types from 12 different manufacturers, and 10 different encapsulated cell types from 9 different manufacturers. Reliability attributes of metallization systems can be classified as major or minor, depending on the severity of the effects observed. As a result of the accelerated testing conducted under the Clemson program, major effects have been observed related to contact resistance and to mechanical adherence and solderability. This paper does not attempt a generalized survey of accelerated test results, but rather concentrates on one particular attribute of metallization that has been observed to cause electrical degradation - increased contact resistance due to Schottky barrier formation. In this example basic semiconductor theory was able to provide an understanding of the electrical effects observed during accelerated stress testing.
Performance Evaluation of Pressure Transducers for Water Impacts
NASA Technical Reports Server (NTRS)
Vassilakos, Gregory J.; Stegall, David E.; Treadway, Sean
2012-01-01
The Orion Multi-Purpose Crew Vehicle is being designed for water landings. In order to benchmark the ability of engineering tools to predict water landing loads, test programs are underway for scale model and full-scale water impacts. These test programs are predicated on the reliable measurement of impact pressure histories. Tests have been performed with a variety of pressure transducers from various manufacturers. Both piezoelectric and piezoresistive devices have been tested. Effects such as thermal shock, pinching of the transducer head, and flushness of the transducer mounting have been studied. Data acquisition issues such as sampling rate and anti-aliasing filtering also have been studied. The response of pressure transducers have been compared side-by-side on an impulse test rig and on a 20-inch diameter hemisphere dropped into a pool of water. The results have identified a range of viable configurations for pressure measurement dependent on the objectives of the test program.
2001-08-06
The test of twin Linear Aerospike XRS-2200 engines, originally built for the X-33 program, was performed on August 6, 2001 at NASA's Sternis Space Center, Mississippi. The engines were fired for the planned 90 seconds and reached a planned maximum power of 85 percent. NASA's Second Generation Reusable Launch Vehicle Program , also known as the Space Launch Initiative (SLI), is making advances in propulsion technology with this third and final successful engine hot fire, designed to test electro-mechanical actuators. Information learned from this hot fire test series about new electro-mechanical actuator technology, which controls the flow of propellants in rocket engines, could provide key advancements for the propulsion systems for future spacecraft. The Second Generation Reusable Launch Vehicle Program, led by NASA's Marshall Space Flight Center in Huntsville, Alabama, is a technology development program designed to increase safety and reliability while reducing costs for space travel. The X-33 program was cancelled in March 2001.
NASA Technical Reports Server (NTRS)
1994-01-01
This is an overview of the White Sands Test Facility's role in ensuring the safety and reliability of materials and hardware slated for launch aboard the Space Shuttle. Engine firings, orbital flights debris impact tests, and propulsion tests are featured as well as illustrating how they provide flight safety testing for the Johnson Space Center, other NASA centers, and various government agencies. It also contains a historical perspective and highlights of major programs that have been participated in as part of NASA.
NASA Astrophysics Data System (ADS)
Wan, Fubin; Tan, Yuanyuan; Jiang, Zhenhua; Chen, Xun; Wu, Yinong; Zhao, Peng
2017-12-01
Lifetime and reliability are the two performance parameters of premium importance for modern space Stirling-type pulse tube refrigerators (SPTRs), which are required to operate in excess of 10 years. Demonstration of these parameters provides a significant challenge. This paper proposes a lifetime prediction and reliability estimation method that utilizes accelerated degradation testing (ADT) for SPTRs related to gaseous contamination failure. The method was experimentally validated via three groups of gaseous contamination ADT. First, the performance degradation model based on mechanism of contamination failure and material outgassing characteristics of SPTRs was established. Next, a preliminary test was performed to determine whether the mechanism of contamination failure of the SPTRs during ADT is consistent with normal life testing. Subsequently, the experimental program of ADT was designed for SPTRs. Then, three groups of gaseous contamination ADT were performed at elevated ambient temperatures of 40 °C, 50 °C, and 60 °C, respectively and the estimated lifetimes of the SPTRs under normal condition were obtained through acceleration model (Arrhenius model). The results show good fitting of the degradation model with the experimental data. Finally, we obtained the reliability estimation of SPTRs through using the Weibull distribution. The proposed novel methodology enables us to take less than one year time to estimate the reliability of the SPTRs designed for more than 10 years.
Ducak, Kate; Keller, Heather
2016-03-01
Few questionnaires to test nutrition knowledge and attitudes of older adults living independently in the community have been developed and tested to assess self-management tools such as Nutri-eSCREEN and other education programs. This study is a first step in the development of a questionnaire designed to evaluate the nutrition knowledge and attitudes of independent older adults (NAK-50+). The steps involved in this study were: (i) drafting initial questions based on the content of the Nutri-eSCREEN education material, (ii) using cognitive interviewing to determine if these questions were understandable and relevant (n = 9 adults ≥50 years of age), and (iii) completing test-retest reliability in a convenient community sample (n = 60 adults ≥50 years of age). Intra-class coefficients (ICC) and kappa were used to determine reliability. A 33-item questionnaire resulted from this development and analysis. ICC for the total score was 0.68 indicating good agreement and thus initial reliability. NAK-50+ is a face valid and reliable questionnaire that assesses nutrition knowledge and attitudes in independent adults aged ≥50 years. Further work to determine construct validity and to refine the questionnaire is warranted. Availability of the questionnaire for this age group will support rigorous evaluation of education and self-management interventions for this segment of the population.
Stockpile Stewardship: How We Ensure the Nuclear Deterrent Without Testing
None
2018-01-16
In the 1990s, the U.S. nuclear weapons program shifted emphasis from developing new designs to dismantling thousands of existing weapons and maintaining a much smaller enduring stockpile. The United States ceased underground nuclear testing, and the Department of Energy created the Stockpile Stewardship Program to maintain the safety, security, and reliability of the U.S. nuclear deterrent without full-scale testing. This video gives a behind the scenes look at a set of unique capabilities at Lawrence Livermore that are indispensable to the Stockpile Stewardship Program: high performance computing, the Superblock category II nuclear facility, the JASPER a two stage gas gun, the High Explosive Applications Facility (HEAF), the National Ignition Facility (NIF), and the Site 300 contained firing facility.
Development of the Systems Thinking Scale for Adolescent Behavior Change
Moore, Shirley M.; Komton, Vilailert; Adegbite-Adeniyi, Clara; Dolansky, Mary A.; Hardin, Heather K.; Borawski, Elaine A.
2017-01-01
This report describes the development and psychometric testing of the Systems Thinking Scale for Adolescent Behavior Change (STS-AB). Following item development, initial assessments of understandability and stability of the STS-AB were conducted in a sample of nine adolescents enrolled in a weight management program. Exploratory factor analysis of the 16-item STS-AB and internal consistency assessments were then done with 359 adolescents enrolled in a weight management program. Test–retest reliability of the STS-AB was .71, p = .03; internal consistency reliability was .87. Factor analysis of the 16-item STS-AB indicated a one-factor solution with good factor loadings, ranging from .40 to .67. Evidence of construct validity was supported by significant correlations with established measures of variables associated with health behavior change. We provide beginning evidence of the reliability and validity of the STS-AB to measure systems thinking for health behavior change in young adolescents. PMID:28303755
Sources of Score Scale Inconsistency. Research Report. ETS RR-11-10
ERIC Educational Resources Information Center
Haberman, Shelby J.; Dorans, Neil J.
2011-01-01
For testing programs that administer multiple forms within a year and across years, score equating is used to ensure that scores can be used interchangeably. In an ideal world, samples sizes are large and representative of populations that hardly change over time, and very reliable alternate test forms are built with nearly identical psychometric…
Crane Cell Testing Support of Nasa/goddard Space Flight Center: an Update
NASA Technical Reports Server (NTRS)
Strawn, Mike; David, Jerry; Rao, Gopalakrishna M.
2001-01-01
The objective of this paper is to verify the quality and reliability of aerospace battery cells and batteries for NASA flight programs, disseminate the data - to develop a plan for in-orbit battery management - to design a cell/battery for future NASA spacecraft and establish a cell test data base for rechargeable cell/batteries.
ERIC Educational Resources Information Center
Longabach, Tanya; Peyton, Vicki
2018-01-01
K-12 English language proficiency tests that assess multiple content domains (e.g., listening, speaking, reading, writing) often have subsections based on these content domains; scores assigned to these subsections are commonly known as subscores. Testing programs face increasing customer demands for the reporting of subscores in addition to the…
The Future Value of Serious Games for Assessment: Where Do We Go Now?
ERIC Educational Resources Information Center
de Klerk, Sebastiaan; Kato, Pamela M.
2017-01-01
Game-based assessments will most likely be an increasing part of testing programs in future generations because they provide promising possibilities for more valid and reliable measurement of students' skills as compared to the traditional methods of assessment like paper-and-pencil tests or performance-based assessments. The current status of…
Performance Assessments in Science: Hands-On Tasks and Scoring Guides.
ERIC Educational Resources Information Center
Stecher, Brian M.; Klein, Stephen P.
In 1992, RAND received a grant from the National Science Foundation to study the technical quality of performance assessments in science and to evaluate their feasibility for use in large-scale testing programs. The specific goals of the project were to assess the reliability and validity of hands-on science testing and to investigate the cost and…
Ciciriello, Sabina; Buchbinder, Rachelle; Osborne, Richard H; Wicks, Ian P
2014-02-01
To develop and test an evidence-based, multimedia patient education program (MPEP) about methotrexate (MTX) treatment for rheumatoid arthritis (RA) and a new measure of patient knowledge [Methotrexate in Rheumatoid Arthritis Knowledge test (MiRAK)]. The content of the MPEP and MiRAK was guided by concept-mapping workshops with patients (N = 24), literature review, health professional, and expert linguistic input. The MPEP and MiRAK underwent multiple stages of testing and revision with patients and health professionals. The MiRAK was administered to RA patients (N = 169) and its properties examined using the Rasch analyses. A subset of respondents (N = 131) repeated the MiRAK to determine test-retest reliability. A before-after pilot study with patients who had recently started MTX (N = 31) tested responsiveness of the MiRAK and feasibility and acceptability of the MPEP. A DVD of 24-minutes duration was produced that presents detailed, evidence-based information about MTX. The Rasch analyses of the 60 MiRAK items revealed that these could be summated into a single score. The MiRAK had good model fit, supporting internal construct validity, good internal consistency (person separation index; 0.84), test-retest reliability (ICC; 0.89), and ability to detect change (ES; 2.38). The before-after study suggested that patients could self-administer the MPEP, with the majority finding it informative and easy to use. We developed a MPEP about MTX treatment for RA, which was found to be user-friendly and easily implementable. The MiRAK is a new scale, testing a broad spectrum of MTX knowledge. Analyses revealed strong evidence for its validity and reliability. Copyright © 2014 Elsevier Inc. All rights reserved.
An experiment in software reliability: Additional analyses using data from automated replications
NASA Technical Reports Server (NTRS)
Dunham, Janet R.; Lauterbach, Linda A.
1988-01-01
A study undertaken to collect software error data of laboratory quality for use in the development of credible methods for predicting the reliability of software used in life-critical applications is summarized. The software error data reported were acquired through automated repetitive run testing of three independent implementations of a launch interceptor condition module of a radar tracking problem. The results are based on 100 test applications to accumulate a sufficient sample size for error rate estimation. The data collected is used to confirm the results of two Boeing studies reported in NASA-CR-165836 Software Reliability: Repetitive Run Experimentation and Modeling, and NASA-CR-172378 Software Reliability: Additional Investigations into Modeling With Replicated Experiments, respectively. That is, the results confirm the log-linear pattern of software error rates and reject the hypothesis of equal error rates per individual fault. This rejection casts doubt on the assumption that the program's failure rate is a constant multiple of the number of residual bugs; an assumption which underlies some of the current models of software reliability. data raises new questions concerning the phenomenon of interacting faults.
Cycle life test. [of secondary spacecraft cells
NASA Technical Reports Server (NTRS)
Harkness, J. D.
1977-01-01
Statistical information concerning cell performance characteristics and limitations of secondary spacecraft cells is presented. Weaknesses in cell design as well as battery weaknesses encountered in various satellite programs are reported. Emphasis is placed on improving the reliability of space batteries.
Operational environments for electrical power wiring on NASA space systems
NASA Technical Reports Server (NTRS)
Stavnes, Mark W.; Hammoud, Ahmad N.; Bercaw, Robert W.
1994-01-01
Electrical wiring systems are used extensively on NASA space systems for power management and distribution, control and command, and data transmission. The reliability of these systems when exposed to the harsh environments of space is very critical to mission success and crew safety. Failures have been reported both on the ground and in flight due to arc tracking in the wiring harnesses, made possible by insulation degradation. This report was written as part of a NASA Office of Safety and Mission Assurance (Code Q) program to identify and characterize wiring systems in terms of their potential use in aerospace vehicles. The goal of the program is to provide the information and guidance needed to develop and qualify reliable, safe, lightweight wiring systems, which are resistant to arc tracking and suitable for use in space power applications. This report identifies the environments in which NASA spacecraft will operate, and determines the specific NASA testing requirements. A summary of related test programs is also given in this report. This data will be valuable to spacecraft designers in determining the best wiring constructions for the various NASA applications.
DOT National Transportation Integrated Search
1984-10-01
The Transit Reliability Information Program (TRIP) is a government-initiated program to assist the transit industry in satisfying its need for transit reliability information. TRIP provides this assistance through the operation of a national data ban...
Dwyer, Tim; Takahashi, Susan Glover; Hynes, Melissa Kennedy; Herold, Jodi; Wasserstein, David; Nousiainen, Markku; Ferguson, Peter; Wadey, Veronica; Murnaghan, M. Lucas; Leroux, Tim; Semple, John; Hodges, Brian; Ogilvie-Harris, Darrell
2014-01-01
Background Assessing residents’ understanding and application of the 6 intrinsic CanMEDS roles (communicator, professional, manager, collaborator, health advocate, scholar) is challenging for postgraduate medical educators. We hypothesized that an objective structured clinical examination (OSCE) designed to assess multiple intrinsic CanMEDS roles would be sufficiently reliable and valid. Methods The OSCE comprised 6 10-minute stations, each testing 2 intrinsic roles using case-based scenarios (with or without the use of standardized patients). Residents were evaluated using 5-point scales and an overall performance rating at each station. Concurrent validity was sought by correlation with in-training evaluation reports (ITERs) from the last 12 months and an ordinal ranking created by program directors (PDs). Results Twenty-five residents from postgraduate years (PGY) 0, 3 and 5 participated. The interstation reliability for total test scores (percent) was 0.87, while reliability for each of the communicator, collaborator, manager and professional roles was greater than 0.8. Total test scores, individual station scores and individual CanMEDS role scores all showed a significant effect by PGY level. Analysis of the PD rankings of intrinsic roles demonstrated a high correlation with the OSCE role scores. A correlation was seen between ITER and OSCE for the communicator role, while the ITER medical expert and total scores highly correlated with the communicator, manager and professional OSCE scores. Conclusion An OSCE designed to assess the intrinsic CanMEDS roles was sufficiently valid and reliable for regular use in an orthopedic residency program. PMID:25078926
Apollo Telescope Mount (ATM) gimballed star tracker. [developed for the Skylab program
NASA Technical Reports Server (NTRS)
Lana, J. D.
1974-01-01
Design and development of six gimballed star trackers for Skylab's Apollo Telescope Mount, which performed successfully on all three manned Skylab missions and accumulated a total usage time of approximately 3,500 hours, is described in terms of configurations, materials and construction, qualification testing, performance, and reliability characteristics. A brief program history and design changes incorporated during the life of the program are also discussed. Extensive drawings, block diagrams, and photographs are provided.
[Computer assisted application of mandarin speech test materials].
Zhang, Hua; Wang, Shuo; Chen, Jing; Deng, Jun-Min; Yang, Xiao-Lin; Guo, Lian-Sheng; Zhao, Xiao-Yan; Shao, Guang-Yu; Han, De-Min
2008-06-01
To design an intelligent speech test system with reliability and convenience using the computer software and to evaluate this system. First, the intelligent system was designed by the Delphi program language. Second, the seven monosyllabic word lists recorded on CD were separated by Cool Edit Pro v2.1 software and put into the system as test materials. Finally, the intelligent system was used to evaluate the equivalence of difficulty between seven lists. Fifty-five college students with normal hearing participated in the study. The seven monosyllabic word lists had equivalent difficulty (F = 1.582, P > 0.05) to the subjects between each other and the system was proved as reliability and convenience. The intelligent system has the feasibility in the clinical practice.
The T/R modules for phased-array antennas
NASA Astrophysics Data System (ADS)
Peignet, Colette; Mancuso, Yves; Resneau, J. Claude
1990-09-01
The concept of phased array radar is critically dependent on the availability of compact, reliable and low power consuming Transmitter/Receiver (T/R) modules. An overview is given on two major programs actually at development stage within the Thomson group and on three major development axis (electrical concept optimization, packaging, and size reduction). The technical feasibility of the concept was proven and the three major axis were enlightened, based on reliability, power added efficiency, and RF tests optimization.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chichester, Heather Jean MacLean; Hayes, Steven Lowe; Dempsey, Douglas
This report summarizes the objectives of the current irradiation testing activities being undertaken by the Advanced Fuels Campaign relative to supporting the development and demonstration of innovative design features for metallic fuels in order to realize reliable performance to ultra-high burnups. The AFC-3 and AFC-4 test series are nearing completion; the experiments in this test series that have been completed or are in progress are reviewed and the objectives and test matrices for the final experiments in these two series are defined. The objectives, testing strategy, and test parameters associated with a future AFC test series, AFC-5, are documented. Finally,more » the future intersections and/or synergies of the AFC irradiation testing program with those of the TREAT transient testing program, emerging needs of proposed Versatile Test Reactor concepts, and the Joint Fuel Cycle Study program’s Integrated Recycle Test are discussed.« less
Status of Hollow Cathode Heater Development for the Space Station Plasma Contactor
NASA Technical Reports Server (NTRS)
Soulas, George C.
1994-01-01
A hollow cathode-based plasma contactor has been selected for use on the Space Station. During the operation of the plasma contactor, the hollow cathode heater will endure approximately 12000 thermal cycles. Since a hollow cathode heater failure would result in a plasma contactor failure, a hollow cathode heater development program was established to produce a reliable heater. The development program includes the heater design, process documents for both heater fabrication and assembly, and heater testing. The heater design was a modification of a sheathed ion thruster cathode heater. Heater tests included testing of the heater unit alone and plasma contactor and ion thruster testing. To date, eight heaters have been or are being processed through heater unit testing, two through plasma contactor testing and three through ion thruster testing, all using direct current power supplies. Comparisons of data from heater unit performance tests before cyclic testing, plasma contactor tests, and ion thruster tests at the ignition input current level show the average deviation of input power and tube temperature near the cathode tip to be +/-0.9 W and +/- 21 C, respectively. Heater unit testing included cyclic testing to evaluate reliability under thermal cycling. The first heater, although damaged during assembly, completed 5985 ignition cycles before failing. Four additional heaters successfully completed 6300, 6300, 700, and 700 cycles. Heater unit testing is currently ongoing for three heaters which have to date accumulated greater than 7250, greater than 5500, and greater than 5500 cycles, respectively.
Reusable Solid Rocket Motor - Accomplishment, Lessons, and a Culture of Success
NASA Technical Reports Server (NTRS)
Moore, D. R.; Phelps, W. J.
2011-01-01
The Reusable Solid Rocket Motor (RSRM) represents the largest solid rocket motor (SRM) ever flown and the only human-rated solid motor. High reliability of the RSRM has been the result of challenges addressed and lessons learned. Advancements have resulted by applying attention to process control, testing, and postflight through timely and thorough communication in dealing with all issues. A structured and disciplined approach was taken to identify and disposition all concerns. Careful consideration and application of alternate opinions was embraced. Focus was placed on process control, ground test programs, and postflight assessment. Process control is mandatory for an SRM, because an acceptance test of the delivered product is not feasible. The RSRM maintained both full-scale and subscale test articles, which enabled continuous improvement of design and evaluation of process control and material behavior. Additionally RSRM reliability was achieved through attention to detail in post flight assessment to observe any shift in performance. The postflight analysis and inspections provided invaluable reliability data as it enables observation of actual flight performance, most of which would not be available if the motors were not recovered. RSRM reusability offered unique opportunities to learn about the hardware. NASA is moving forward with the Space Launch System that incorporates propulsion systems that takes advantage of the heritage Shuttle and Ares solid motor programs. These unique challenges, features of the RSRM, materials and manufacturing issues, and design improvements will be discussed in the paper.
DOT National Transportation Integrated Search
1981-08-01
The Transit Reliability Information Program (TRIP) is a government-initiated program to assist the transit industry in satisfying its need for transit reliability information. TRIP provides this assistance through the operation of a national Data Ban...
Fundamentals of endoscopic surgery: creation and validation of the hands-on test.
Vassiliou, Melina C; Dunkin, Brian J; Fried, Gerald M; Mellinger, John D; Trus, Thadeus; Kaneva, Pepa; Lyons, Calvin; Korndorffer, James R; Ujiki, Michael; Velanovich, Vic; Kochman, Michael L; Tsuda, Shawn; Martinez, Jose; Scott, Daniel J; Korus, Gary; Park, Adrian; Marks, Jeffrey M
2014-03-01
The Fundamentals of Endoscopic Surgery™ (FES) program consists of online materials and didactic and skills-based tests. All components were designed to measure the skills and knowledge required to perform safe flexible endoscopy. The purpose of this multicenter study was to evaluate the reliability and validity of the hands-on component of the FES examination, and to establish the pass score. Expert endoscopists identified the critical skill set required for flexible endoscopy. They were then modeled in a virtual reality simulator (GI Mentor™ II, Simbionix™ Ltd., Airport City, Israel) to create five tasks and metrics. Scores were designed to measure both speed and precision. Validity evidence was assessed by correlating performance with self-reported endoscopic experience (surgeons and gastroenterologists [GIs]). Internal consistency of each test task was assessed using Cronbach's alpha. Test-retest reliability was determined by having the same participant perform the test a second time and comparing their scores. Passing scores were determined by a contrasting groups methodology and use of receiver operating characteristic curves. A total of 160 participants (17 % GIs) performed the simulator test. Scores on the five tasks showed good internal consistency reliability and all had significant correlations with endoscopic experience. Total FES scores correlated 0.73, with participants' level of endoscopic experience providing evidence of their validity, and their internal consistency reliability (Cronbach's alpha) was 0.82. Test-retest reliability was assessed in 11 participants, and the intraclass correlation was 0.85. The passing score was determined and is estimated to have a sensitivity (true positive rate) of 0.81 and a 1-specificity (false positive rate) of 0.21. The FES hands-on skills test examines the basic procedural components required to perform safe flexible endoscopy. It meets rigorous standards of reliability and validity required for high-stakes examinations, and, together with the knowledge component, may help contribute to the definition and determination of competence in endoscopy.
The 25-KVA amorphous metal-core transformer developmental test report
NASA Astrophysics Data System (ADS)
Urata, G. V.; Franchi, J. O.; Franchi, P. E.
1989-08-01
NCEL has completed a test and evaluation program for 25-kVA amorphous metal-core transformers. These transformers save energy by reducing no-load losses by 60 to 70 percent. No-load losses are estimated to cost the Navy millions annually and if all of the Navy transformers were replaced by amorphous metal-core transformers, the Navy would save millions a year. The program objective was to evaluate the electrical performance and operational reliability of the amorphous metal-core transformers compared to conventional silicon-steel transformers.
NASA Technical Reports Server (NTRS)
Welge, R. T.
1972-01-01
A CH-54B Skycrane helicopter was fabricated with boron/epoxy reinforced stringers in the tail cone and boron/epoxy tubes in the tail skid. The fabrication of the tail cone was made with conventional tooling, production shop personnel, and no major problems. The flight test program includes a stress and vibration survey using strain gages and vibration transducers located in critical areas. The program to inspect and monitor the reliability of the components is discussed.
Kurland, Jacquie; Naeser, Margaret A.; Baker, Errol H.; Doron, Karl; Martin, Paula I.; Seekins, Heidi E.; Bogdan, Andrew; Renshaw, Perry; Yurgelun-Todd, Deborah
2005-01-01
Cortical reorganization in poststroke aphasia is not well understood. Few studies have investigated neural mechanisms underlying language recovery in severe aphasia patients, who are typically viewed as having a poor prognosis for language recovery. Although test-retest reliability is routinely demonstrated during collection of language data in single-subject aphasia research, this is rarely examined in fMRI studies investigating the underlying neural mechanisms in aphasia recovery. The purpose of this study was to acquire fMRI test-retest data examining semantic decisions both within and between two aphasia patients. Functional MRI was utilized to image individuals with chronic, moderate-severe nonfluent aphasia during nonverbal, yes/no button-box semantic judgments of iconic sentences presented in the Computer-assisted Visual Communication (C-ViC) program. We investigated the critical issue of intra-subject reliability by exploring similarities and differences in regions of activation during participants’ performance of identical tasks twice on the same day. Each participant demonstrated high intra-subject reliability, with response decrements typical of task familiarity. Differences between participants included greater left hemisphere perilesional activation in the individual with better response to C-ViC training. This study provides fMRI reliability in chronic nonfluent aphasia, and adds to evidence supporting differences in individual cortical reorganization in aphasia recovery. PMID:15706052
Evaluation program for secondary spacecraft cells
NASA Technical Reports Server (NTRS)
Christy, D. E.; Harkness, J. D.
1973-01-01
A life cycle test of secondary electric batteries for spacecraft applications was conducted. A sample number of nickel cadmium batteries were subjected to general performance tests to determine the limit of their actual capabilities. Weaknesses discovered in cell design are reported and aid in research and development efforts toward improving the reliability of spacecraft batteries. A statistical analysis of the life cycle prediction and cause of failure versus test conditions is provided.
Hollow cathode heater development for the Space Station plasma contactor
NASA Technical Reports Server (NTRS)
Soulas, George C.
1993-01-01
A hollow cathode-based plasma contactor has been selected for use on the Space Station. During the operation of the plasma contactor, the hollow cathode heater will endure approximately 12000 thermal cycles. Since a hollow cathode heater failure would result in a plasma contactor failure, a hollow cathode heater development program was established to produce a reliable heater design. The development program includes the heater design, process documents for both heater fabrication and assembly, and heater testing. The heater design was a modification of a sheathed ion thruster cathode heater. Three heaters have been tested to date using direct current power supplies. Performance testing was conducted to determine input current and power requirements for achieving activation and ignition temperatures, single unit operational repeatability, and unit-to-unit operational repeatability. Comparisons of performance testing data at the ignition input current level for the three heaters show the unit-to-unit repeatability of input power and tube temperature near the cathode tip to be within 3.5 W and 44 degrees C, respectively. Cyclic testing was then conducted to evaluate reliability under thermal cycling. The first heater, although damaged during assembly, completed 5985 ignition cycles before failing. Two additional heaters were subsequently fabricated and have completed 3178 cycles to date in an on-going test.
Considerations in STS payload environmental verification
NASA Technical Reports Server (NTRS)
Keegan, W. B.
1978-01-01
Considerations regarding the Space Transportation System (STS) payload environmental verification are reviewed. It is noted that emphasis is placed on testing at the subassembly level and that the basic objective of structural dynamic payload verification is to ensure reliability in a cost-effective manner. Structural analyses consist of: (1) stress analysis for critical loading conditions, (2) model analysis for launch and orbital configurations, (3) flight loads analysis, (4) test simulation analysis to verify models, (5) kinematic analysis of deployment/retraction sequences, and (6) structural-thermal-optical program analysis. In addition to these approaches, payload verification programs are being developed in the thermal-vacuum area. These include the exposure to extreme temperatures, temperature cycling, thermal-balance testing and thermal-vacuum testing.
Space Station Freedom primary power wiring requirements
NASA Technical Reports Server (NTRS)
Hill, Thomas J.
1994-01-01
The Space Station Freedom (SSF) Program requirements are a 30 year reliable service life in low Earth orbit in hard vacuum or pressurized module service without detrimental degradation. Specific requirements are outlined in this presentation for SSF primary power and cable insulation. The primary power cable status and the WP-4 planned cable test program are also reviewed along with Rocketdyne-WP04 prime insulation candidates.
Code of Federal Regulations, 2011 CFR
2011-01-01
... HUMAN RELIABILITY PROGRAM Establishment of and Procedures for the Human Reliability Program General Provisions § 712.1 Purpose. This part establishes the policies and procedures for a Human Reliability Program... judgment and reliability may be impaired by physical or mental/personality disorders, alcohol abuse, use of...
The major objective of the Soliditech, Inc., SITE demonstration was to develop reliable performance and cost information about the Soliditech solidification, stabilization technology. The Soliditech process mixes hazardous waste materials with Portland cement or pozzolanic m...
HELLFIRE 6-DOF Simulation Validation for Stockpile Reliability Program with Seeker Test Data
1994-09-12
Research, Development and Engineering Centeri U.S. Army Missile Command Willy Albanes and Eddie Hammons COLSA Corporation Lisa Collins AMTEC Corporation I...I 3 AMTEC Corporation ATTN: Lisa Collins 500 Wynn Drive, Suite 314 H
Statistical Analysis Tools for Learning in Engineering Laboratories.
ERIC Educational Resources Information Center
Maher, Carolyn A.
1990-01-01
Described are engineering programs that have used automated data acquisition systems to implement data collection and analyze experiments. Applications include a biochemical engineering laboratory, heat transfer performance, engineering materials testing, mechanical system reliability, statistical control laboratory, thermo-fluid laboratory, and a…
A quality management systems approach for CD4 testing in resource-poor settings.
Westerman, Larry E; Kohatsu, Luciana; Ortiz, Astrid; McClain, Bernice; Kaplan, Jonathan; Spira, Thomas; Marston, Barbara; Jani, Ilesh V; Nkengasong, John; Parsons, Linda M
2010-10-01
Quality assurance (QA) is a systematic process to monitor and improve clinical laboratory practices. The fundamental components of a laboratory QA program include providing a functional and safe laboratory environment, trained and competent personnel, maintained equipment, adequate supplies and reagents, testing of appropriate specimens, internal monitoring of quality, accurate reporting, and external quality assessments. These components are necessary to provide accurate and precise CD4 T-cell counts, an essential test to evaluate start of and monitor effectiveness of antiretroviral therapy for HIV-infected patients. In recent years, CD4 testing has expanded dramatically in resource-limited settings. Information on a CD4 QA program as described in this article will provide guidelines not only for clinical laboratory staff but also for managers of programs responsible for supporting CD4 testing. All agencies involved in implementing CD4 testing must understand the needs of the laboratory and provide advocacy, guidance, and financial support to established CD4 testing sites and programs. This article describes and explains the procedures that must be put in place to provide reliable CD4 determinations in a variety of settings.
Huang, Chih-Ling; Cheng, Chung-Ping; Huang, Hui-Wen
2013-10-01
The purpose of this study was to develop a scale to measure the social smoking motives of adult male smokers using a Chinese social context. Three phases were conducted between February 2006 and May 2009. First, the initial instrument development was guided by a literature review, interviews with smokers, and item analysis. Second, the validity and reliability of the refined scale were tested. The factor structures of the Social Smoking Measures (SSM-12) scale were validated. The final scale consists of 12 items. Two factors that account for 49.2% of the variance emerged from the exploratory factor analysis. Cronbach's alpha was .88, and test-retest reliability was .82. The results of the confirmatory factor analysis indicated that the SSM model was a two-correlated factor. Field testing revealed the SSM-12 to be a reliable and valid Chinese-language instrument to measure social smoking motives, which can be used to guide nursing interventions that support culturally and socially appropriate smoking cessation programs.
Beemster, Timo T; van Velzen, Judith M; van Bennekom, Coen A M; Reneman, Michiel F; Frings-Dresen, Monique H W
2018-03-16
The purpose of this study was to assess test-retest reliability, agreement, and responsiveness of questionnaires on productivity loss (iPCQ-VR) and healthcare utilization (TiCP-VR) for sick-listed workers with chronic musculoskeletal pain who were referred to vocational rehabilitation. Methods Test-retest reliability and agreement was assessed with a 2-week interval. Responsiveness was assessed at discharge after a 15-week vocational rehabilitation (VR) program. Data was obtained from six Dutch VR centers. Test-retest reliability was determined with intraclass correlation coefficient (ICC) and Cohen's kappa. Agreement was determined by Standard Error of Measurement (SEM), smallest detectable changes (on group and individual level), and percentage observed, positive and negative agreement. Responsiveness was determined with area under the curve (AUC) obtained from receiver operation characteristic (ROC). Results A sample of 52 participants on test-retest reliability and agreement, and a sample of 223 on responsiveness were included in the analysis. Productivity loss (iPCQ-VR): ICCs ranged from 0.52 to 0.90, kappa ranged from 0.42 to 0.96, and AUC ranged from 0.55 to 0.86. Healthcare utilization (TiCP-VR): ICC was 0.81, and kappa values of the single healthcare utilization items ranged from 0.11 to 1.00. Conclusions The iPCQ-VR showed good measurement properties on working status, number of hours working per week and long-term sick leave, and low measurement properties on short-term sick leave and presenteeism. The TiCP-VR showed adequate reliability on all healthcare utilization items together and medication use, but showed low measurement properties on the single healthcare utilization items.
An International Round-Robin Test of NDE Reliability for PWSCC
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schuster, George J.; Cumblidge, Stephen E.; Doctor, Steven R.
2007-12-01
In this paper we describe the round robin tests that have been designed and are being conducted in the international program. Participants in the PINC have offered more than 30 test blocks for use in round-robin tests of NDE effectiveness. The test blocks have more than 130 flaws in nickel-base weld metal that are intended to simulate PWSCC in a variety of component geometries. NDE techniques representative of current in-service inspections are being applied, along with emerging NDE approaches.
Development of a scale to measure individuals’ ratings of peace
2014-01-01
Background The evolving concept of peace-building and the interplay between peace and health is examined in many venues, including at the World Health Assembly. However, without a metric to determine effectiveness of intervention programs all efforts are prone to subjective assessment. This paper develops a psychometric index that lays the foundation for measuring community peace stemming from intervention programs. Methods After developing a working definition of ‘peace’ and delineating a Peace Evaluation Across Cultures and Environments (PEACE) scale with seven constructs comprised of 71 items, a beta version of the index was pilot-tested. Two hundred and fifty subjects in three sites in the U.S. were studied using a five-point Likert scale to evaluate the psychometric functioning of the PEACE scale. Known groups validation was performed using the SOS-10. In addition, test-retest reliability was performed on 20 subjects. Results The preliminary data demonstrated that the scale has acceptable psychometric properties for measuring an individual’s level of peacefulness. The study also provides reliability and validity data for the scale. The data demonstrated internal consistency, correlation between data and psychological well-being, and test-retest reliability. Conclusions The PEACE scale may serve as a novel assessment tool in the health sector and be valuable in monitoring and evaluating the peace-building impact of health initiatives in conflict-affected regions. PMID:25298781
Qualification testing of flat-plate photovoltaic modules
NASA Technical Reports Server (NTRS)
Hoffman, A. R.; Griffith, J. S.; Ross, R. G., Jr.
1982-01-01
The placement of photovoltaic modules in various applications, in climates and locations throughout the world, results in different degrees and combinations of environmental and electrical stress. Early detection of module reliability deficiencies via laboratory testing is necessary for achieving long, satisfactory field service. This overview paper describes qualification testing techniques being used in the US Department of Energy's flat-plate terrestrial photovoltaic development program in terms of their significance, rationale for specified levels and durations, and test results.
Flight Test Experience with an Electromechanical Actuator on the F-18 Systems Research Aircraft
NASA Technical Reports Server (NTRS)
Jensen, Stephen C.; Jenney, Gavin D.; Raymond, Bruce; Dawson, David; Flick, Brad (Technical Monitor)
2000-01-01
Development of reliable power-by-wire actuation systems for both aeronautical and space applications has been sought recently to eliminate hydraulic systems from aircraft and spacecraft and thus improve safety, efficiency, reliability, and maintainability. The Electrically Powered Actuation Design (EPAD) program was a joint effort between the Air Force, Navy, and NASA to develop and fly a series of actuators validating power-by-wire actuation technology on a primary flight control surface of a tactical aircraft. To achieve this goal, each of the EPAD actuators was installed in place of the standard hydraulic actuator on the left aileron of the NASA F/A-18B Systems Research Aircraft (SRA) and flown throughout the SRA flight envelope. Numerous parameters were recorded, and overall actuator performance was compared with the performance of the standard hydraulic actuator on the opposite wing. This paper discusses the integration and testing of the EPAD electromechanical actuator (EMA) on the SRA. The architecture of the EMA system is discussed, as well as its integration with the F/A-18 Flight Control System. The flight test program is described, and actuator performance is shown to be very close to that of the standard hydraulic actuator it replaced. Lessons learned during this program are presented and discussed, as well as suggestions for future research.
Flight Test Experience With an Electromechanical Actuator on the F-18 Systems Research Aircraft
NASA Technical Reports Server (NTRS)
Jensen, Stephen C.; Jenney, Gavin D.; Raymond, Bruce; Dawson, David
2000-01-01
Development of reliable power-by-wire actuation systems for both aeronautical and space applications has been sought recently to eliminate hydraulic systems from aircraft and spacecraft and thus improve safety, efficiency, reliability, and maintainability. The Electrically Powered Actuation Design (EPAD) program was a joint effort between the Air Force, Navy, and NASA to develop and fly a series of actuators validating power-by-wire actuation technology on a primary flight control surface of a tactical aircraft. To achieve this goal, each of the EPAD actuators was installed in place of the standard hydraulic actuator on the left aileron of the NASA F/A-18B Systems Research Aircraft (SRA) and flown throughout the SRA flight envelope. Numerous parameters were recorded, and overall actuator performance was compared with the performance of the standard hydraulic actuator on the opposite wing. This paper discusses the integration and testing of the EPAD electromechanical actuator (EMA) on the SRA. The architecture of the EMA system is discussed, as well as its integration with the F/A-18 Flight Control System. The flight test program is described, and actuator performance is shown to be very close to that of the standard hydraulic actuator it replaced. Lessons learned during this program are presented and discussed, as well as suggestions for future research.
Use of clinical movement screening tests to predict injury in sport
Chimera, Nicole J; Warren, Meghan
2016-01-01
Clinical movement screening tests are gaining popularity as a means to determine injury risk and to implement training programs to prevent sport injury. While these screens are being used readily in the clinical field, it is only recently that some of these have started to gain attention from a research perspective. This limits applicability and poses questions to the validity, and in some cases the reliability, of the clinical movement tests as they relate to injury prediction, intervention, and prevention. This editorial will review the following clinical movement screening tests: Functional Movement Screen™, Star Excursion Balance Test, Y Balance Test, Drop Jump Screening Test, Landing Error Scoring System, and the Tuck Jump Analysis in regards to test administration, reliability, validity, factors that affect test performance, intervention programs, and usefulness for injury prediction. It is important to review the aforementioned factors for each of these clinical screening tests as this may help clinicians interpret the current body of literature. While each of these screening tests were developed by clinicians based on what appears to be clinical practice, this paper brings to light that this is a need for collaboration between clinicians and researchers to ensure validity of clinically meaningful tests so that they are used appropriately in future clinical practice. Further, this editorial may help to identify where the research is lacking and, thus, drive future research questions in regards to applicability and appropriateness of clinical movement screening tools. PMID:27114928
Stockpile stewardship past, present, and future
DOE Office of Scientific and Technical Information (OSTI.GOV)
Adams, Marvin L., E-mail: mladams@tamu.edu
2014-05-09
The U.S. National Academies released a report in 2012 on technical issues related to the Comprehensive Test Ban Treaty. One important question addressed therein is whether the U.S. could maintain a safe, secure, and reliable nuclear-weapons stockpile in the absence of nuclear-explosion testing. Here we discuss two main conclusions from the 2012 Academies report, which we paraphrase as follows: 1) Provided that sufficient resources and a national commitment to stockpile stewardship are in place, the U.S. has the technical capabilities to maintain a safe, secure, and reliable stockpile of nuclear weapons into the foreseeable future without nuclear-explosion testing. 2) Doingmore » this would require: a) a strong weapons science and engineering program that addresses gaps in understanding; b) an outstanding workforce that applies deep and broad weapons expertise to deliver solutions to stockpile problems; c) a vigorous, stable surveillance program that delivers the requisite data; d) production facilities that meet stewardship needs. We emphasize that these conclusions are independent of CTBT ratification-they apply provided only that the U.S. continues its nuclear-explosion moratorium.« less
Psychometrics of the MHSIP Adult Consumer Survey.
Jerrell, Jeanette M
2006-10-01
The reliability and validity of the Mental Health Statistics Improvement Program (MHSIP) Adult Consumer Survey were assessed in a statewide convenience sample of 459 persons with severe mental illness served through a public mental health system. Consistent with previous findings and the intent of its developers, three factors were identified that demonstrate good internal consistency, moderate test-retest reliability, and good convergent validity with consumer perceptions of other aspects of their care. The reliability and validity of the MHSIP Adult Consumer Survey documented in this study underscore its scientific and practical utility as an abbreviated tool for assessing access, quality and appropriateness, and outcome in mental health service systems.
McGillicuddy, Neil B; Rychtarik, Robert G; Morsheimer, Elizabeth T
2004-12-01
This article reports on the generalizability, reliability, and construct validity of the Parent Situation Inventory (PSI), a role-play measure of coping skills in parents experiencing problems from an adolescent's drug and alcohol use. Generalizability was robust (.80) and alternate form and test-retest reliability were satisfactory. PSI skillfulness was negatively related to the parent's own substance use and to the adolescent's alcohol use. The PSI shows promise as a reliable and potentially valid measure of coping in this population and has direct implications for developing and evaluating skill-based parent training programs. Copyright 2004 APA.
Application of Kingview and PLC in friction durability test system
NASA Astrophysics Data System (ADS)
Gao, Yinhan; Cui, Jing; Yang, Kaiyu; Ke, Hui; Song, Bing
2013-01-01
Using PLC and Kingview software, a friction durability test system is designed. The overall program, hardware configuration, software structure and monitoring interface are described in detail. PLC ensures the stability of data acquisition, and the KingView software makes the HMI easy to manipulate. The practical application shows that the proposed system is cheap, economical and highly reliable.
ERIC Educational Resources Information Center
Berber, Aslihan; García Laborda, Jesús
2015-01-01
There are different opinions about using technology in the assessment field of education regarding computer-assisted assessments. People have some concerns such as its application, reliability and so on. It seems that those concerns may decrease with the developing technology in the following years since computer-based testing programs are…
Automatically generated acceptance test: A software reliability experiment
NASA Technical Reports Server (NTRS)
Protzel, Peter W.
1988-01-01
This study presents results of a software reliability experiment investigating the feasibility of a new error detection method. The method can be used as an acceptance test and is solely based on empirical data about the behavior of internal states of a program. The experimental design uses the existing environment of a multi-version experiment previously conducted at the NASA Langley Research Center, in which the launch interceptor problem is used as a model. This allows the controlled experimental investigation of versions with well-known single and multiple faults, and the availability of an oracle permits the determination of the error detection performance of the test. Fault interaction phenomena are observed that have an amplifying effect on the number of error occurrences. Preliminary results indicate that all faults examined so far are detected by the acceptance test. This shows promise for further investigations, and for the employment of this test method on other applications.
Lapsley Miller, Judi A; Reed, Charlotte M; Robinson, Sarah R; Perez, Zachary D
2018-02-21
Clinical pure-tone audiometry is conducted using stimuli delivered through supra-aural headphones or insert earphones. The stimuli are calibrated in an acoustic (average ear) coupler. Deviations in individual-ear acoustics from the coupler acoustics affect test validity, and variations in probe insertion and headphone placement affect both test validity and test-retest reliability. Using an insert earphone designed for otoacoustic emission testing, which contains a microphone and loudspeaker, an individualized in-the-ear calibration can be calculated from the ear-canal sound pressure measured at the microphone. However, the total sound pressure level (SPL) measured at the microphone may be affected by standing-wave nulls at higher frequencies, producing errors in stimulus level of up to 20 dB. An alternative is to calibrate using the forward pressure level (FPL) component, which is derived from the total SPL using a wideband acoustic immittance measurement, and represents the pressure wave incident on the eardrum. The objective of this study is to establish test-retest reliability for FPL calibration of pure-tone audiometry stimuli, compared with in-the-ear and coupler sound pressure calibrations. The authors compared standard audiometry using a modern clinical audiometer with TDH-39P supra-aural headphones calibrated in a coupler to a prototype audiometer with an ER10C earphone calibrated three ways: (1) in-the-ear using the total SPL at the microphone, (2) in-the-ear using the FPL at the microphone, and (3) in a coupler (all three are derived from the same measurement). The test procedure was similar to that commonly used in hearing-conservation programs, using pulsed-tone test frequencies at 0.5, 1, 2, 3, 4, 6, and 8 kHz, and an automated modified Hughson-Westlake audiometric procedure. Fifteen adult human participants with normal to mildly-impaired hearing were selected, and one ear from each was tested. Participants completed 10 audiograms on each system, with test-order randomly varied and with headphones and earphones refitted by the tester between tests. Fourteen of 15 ears had standing-wave nulls present between 4 and 8 kHz. The mean intrasubject SD at 6 and 8 kHz was lowest for the FPL calibration, and was comparable with the low-frequency reliability across calibration methods. This decrease in variability translates to statistically-derived significant threshold shift criteria indicating that 15 dB shifts in hearing can be reliably detected at 6 and 8 kHz using FPL-calibrated ER10C earphones, compared with 20 to 25 dB shifts using standard TDH-39P headphones with a coupler calibration. These results indicate that reliability is better with insert earphones, especially with in-the-ear FPL calibration, compared with a standard clinical audiometer with supra-aural headphones. However, in-the-ear SPL calibration should not be used due to its sensitivity to standing waves. The improvement in reliability is clinically meaningful, potentially allowing hearing-conservation programs to more confidently determine significant threshold shifts at 6 kHz-a key frequency for the early detection of noise-induced hearing loss.
Miniature sheathed thermocouples for turbine blade temperature measurement
NASA Technical Reports Server (NTRS)
Holanda, R.; Glawe, G. E.; Krause, L. N.
1974-01-01
An investigation was made of sheathed thermocouples for turbine blade temperature measurements. Tests were performed on the Chromel-Alumel sheathed thermocouples with both two-wire and single-wire configurations. Sheath diameters ranged from 0.25 to 0.76 mm, and temperatures ranged from 1080 to 1250 K. Both steady-state and thermal cycling tests were performed for times up to 450 hr. Special-order and commercial-grade thermocouples were tested. The tests showed that special-order single-wire sheathed thermocouples can be obtained that are reliable and accurate with diameters as small as 0.25 mm. However, all samples of 0.25-mm-diameter sheathed commercial-grade two-wire and single-wire thermocouples that were tested showed unacceptable drift rates for long-duration engine testing programs. The drift rates were about 1 percent in 10 hr. A thermocouple drift test is recommended in addition to the normal acceptance tests in order to select reliable miniature sheathed thermocouples for turbine blade applications.
Ceramic Technology For Advanced Heat Engines Project
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1990-12-01
Significant accomplishments in fabricating ceramic components for the Department of Energy (DOE), National Aeronautics and Space Administration (NASA), and Department of Defense (DoD) advanced heat engine programs have provided evidence that the operation of ceramic parts in high-temperature engine environments is feasible. However, these programs have also demonstrated that additional research is needed in materials and processing development, design methodology, and data base and life prediction before industry will have a sufficient technology base from which to produce reliable cost-effective ceramic engine components commercially. The objective of the project is to develop the industrial technology base required for reliable ceramicsmore » for application in advanced automotive heat engines. The project approach includes determining the mechanisms controlling reliability, improving processes for fabricating existing ceramics, developing new materials with increased reliability, and testing these materials in simulated engine environments to confirm reliability. Although this is a generic materials project, the focus is on the structural ceramics for advanced gas turbine and diesel engines, ceramic bearings and attachments, and ceramic coatings for thermal barrier and wear applications in these engines. This advanced materials technology is being developed in parallel and close coordination with the ongoing DOE and industry proof of concept engine development programs. To facilitate the rapid transfer of this technology to U.S. industry, the major portion of the work is being done in the ceramic industry, with technological support from government laboratories, other industrial laboratories, and universities. Abstracts prepared for appropriate papers.« less
Mi, Misa; Moseley, James L; Green, Michael L
2012-02-01
Many residency programs offer training in evidence-based medicine (EBM). However, these curricula often fail to achieve optimal learning outcomes, perhaps because they neglect various contextual factors in the learning environment. We developed and validated an instrument to characterize the environment for EBM learning and practice in residency programs. An EBM Environment Scale was developed following scale development principles. A survey was administered to residents across six programs in primary care specialties at four medical centers. Internal consistency reliability was analyzed with Cronbach's coefficient alpha. Validity was assessed by comparing predetermined subscales with the survey's internal structure as assessed via factor analysis. Scores were also compared for subgroups based on residency program affiliation and residency characteristics. Out of 262 eligible residents, 124 completed the survey (response rate 47%). The overall mean score was 3.89 (standard deviation=0.56). The initial reliability analysis of the 48-item scale had a high reliability coefficient (Cronbach α=.94). Factor analysis and further item analysis resulted in a shorter 36-item scale with a satisfactory reliability coefficient (Cronbach α=.86). Scores were higher for residents with prior EBM training in medical school (4.14 versus 3.62) and in residency (4.25 versus 3.69). If further testing confirms its properties, the EBM Environment Scale may be used to understand the influence of the learning environment on the effectiveness of EBM training. Additionally, it may detect changes in the EBM learning environment in response to programmatic or institutional interventions.
Stockpile Stewardship: How We Ensure the Nuclear Deterrent Without Testing
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
2014-09-04
In the 1990s, the U.S. nuclear weapons program shifted emphasis from developing new designs to dismantling thousands of existing weapons and maintaining a much smaller enduring stockpile. The United States ceased underground nuclear testing, and the Department of Energy created the Stockpile Stewardship Program to maintain the safety, security, and reliability of the U.S. nuclear deterrent without full-scale testing. This video gives a behind the scenes look at a set of unique capabilities at Lawrence Livermore that are indispensable to the Stockpile Stewardship Program: high performance computing, the Superblock category II nuclear facility, the JASPER a two stage gas gun,more » the High Explosive Applications Facility (HEAF), the National Ignition Facility (NIF), and the Site 300 contained firing facility.« less
NASA Technical Reports Server (NTRS)
Sim, A. G.
1973-01-01
A brief study was made to assess the applicability of the Newton-Raphson digital computer program as a routine technique for extracting aerodynamic derivatives from flight tests of lifting body types of vehicles. Lateral-direction flight data from flight tests of the HL-10 lifting body reserch vehicle were utilized. The results in general, show the computer program to be a reliable and expedient means for extracting derivatives for this class of vehicles as a standard procedure. This result was true even when stability augmentation was used. As a result of the study, a credible set of HL-10 lateral-directional derivatives was obtained from flight data. These derivatives are compared with results from wind-tunnel tests.
A Year in the Life of the NASA Electronic Parts and Packaging (NEPP) Program
NASA Technical Reports Server (NTRS)
Label, Kenneth A.
2017-01-01
NEPP Mission Statement: Provide NASAs leadership for developing and maintaining guidance for the screening, qualification, test, and reliable usage of electrical, electronic, and electromechanical (EEE) parts by NASA, in collaboration with other government Agencies and industry.
Utilization survey of prototype structural test article
NASA Technical Reports Server (NTRS)
Baber, S.; Mcdaniel, H. M.; Berry, M. J.
1974-01-01
A survey was conducted of six aerospace companies and two NASA agencies to determine how prototype structural test articles are used in flight operations. The prototype structures are airframes and similar devices which are used for testing and generally are not flown. The survey indicated the following: (1) prototype test articles are not being discarded after development testing is complete, but are used for other purposes, (2) only two cases of prototypes being refurbished and flown were identified, (3) protective devices and inspection techniques are available to prevent or minimize test article damage, (4) substitute programs from design verification are availabel in lieu of using prototype structural articles, and (5) there is a trend away from dedicated test articles. Four options based on these study results were identified to reduce test and hardware costs without compromising reliability of the flight program.
SPSS and SAS programs for generalizability theory analyses.
Mushquash, Christopher; O'Connor, Brian P
2006-08-01
The identification and reduction of measurement errors is a major challenge in psychological testing. Most investigators rely solely on classical test theory for assessing reliability, whereas most experts have long recommended using generalizability theory instead. One reason for the common neglect of generalizability theory is the absence of analytic facilities for this purpose in popular statistical software packages. This article provides a brief introduction to generalizability theory, describes easy to use SPSS, SAS, and MATLAB programs for conducting the recommended analyses, and provides an illustrative example, using data (N = 329) for the Rosenberg Self-Esteem Scale. Program output includes variance components, relative and absolute errors and generalizability coefficients, coefficients for D studies, and graphs of D study results.
US DOE Regional Test Centers Program - 2016 Annual Report.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stein, Joshua
The US Department of Energy’s Regional Test Center (RTC) program provides outdoor validation and bankability data for innovative solar technologies at five sites across the US representing a range of climate conditions. Data helps get new technologies to market faster and improves US industry competitiveness. Managed by Sandia National Laboratories and the National Renewable Energy Laboratory (NREL), the RTC program partners with US manufacturers of photovoltaic (PV) technologies, including modules, inverters, and balance-of-system equipment. The study is collaborative, with manufacturers (also known as RTC industry partners) and the national labs working together on a system design and validation strategy thatmore » meets a clearly defined set of performance and reliability objectives.« less
78 FR 49595 - Aviation Rulemaking Advisory Committee-New Task
Federal Register 2010, 2011, 2012, 2013, 2014
2013-08-14
... the new ARAC activity and solicits membership for the Maintenance Reliability Program Working Group... establish the Maintenance Reliability Program Working Group. The working group will serve as staff to ARAC... programs. The Maintenance Reliability Program Working Group will provide advice and recommendations on the...
Transit Reliability Information Program Participants Guidelines
DOT National Transportation Integrated Search
1981-03-01
The document provides guidelines for participation in the Transit Reliability Information Program (TRIP). TRIP is a government-initiated program designed to assist the transit industry in satisfying its need for transit equipment reliability data. TR...
Postflight analysis for Delta Program Mission no. 113: COS-B Mission
NASA Technical Reports Server (NTRS)
1976-01-01
On 8 August 1975, the COS-B spacecraft was launched successfully from the Western Test Range (Delta Program Mission No. 113). The launch vehicle was a three stage Extended Long Tank Delta DSV-3P-11B vehicle. Postflight analyses performed in connection with flight are presented. Vehicle trajectory, stage performance, vehicle reliability and the propulsion, guidance, flight control, electronics, mechanical and structural systems are evaluated.
Language-Specific Attention Treatment for Aphasia: Description and Preliminary Findings.
Peach, Richard K; Nathan, Meghana R; Beck, Katherine M
2017-02-01
The need for a specific, language-based treatment approach to aphasic impairments associated with attentional deficits is well documented. We describe language-specific attention treatment, a specific skill-based approach for aphasia that exploits increasingly complex linguistic tasks that focus attention. The program consists of eight tasks, some with multiple phases, to assess and treat lexical and sentence processing. Validation results demonstrate that these tasks load on six attentional domains: (1) executive attention; (2) attentional switching; (3) visual selective attention/processing speed; (4) sustained attention; (5) auditory-verbal working memory; and (6) auditory processing speed. The program demonstrates excellent inter- and intrarater reliability and adequate test-retest reliability. Two of four people with aphasia exposed to this program demonstrated good language recovery whereas three of the four participants showed improvements in auditory-verbal working memory. The results provide support for this treatment program in patients with aphasia having no greater than a moderate degree of attentional impairment. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.
Design and testing of the Space Station Freedom Propellant Tank Assembly
NASA Technical Reports Server (NTRS)
Dudley, D. D.; Thonet, T. A.; Goforth, A. M.
1992-01-01
Propellant storage and management functions for the Propulsion Module of the U.S. Space Station Freedom are provided by the Propellant Tank Assembly (PTA). The PTA consists of a surface-tension type propellant acquisition device contained within a welded titanium pressure vessel. The PTA design concept was selected with high reliability and low program risk as primary goals in order to meet stringent NASA structural, expulsion, fracture control and reliability requirements. The PTA design makes use of Shuttle Orbital Maneuvering System and Peacekeeper Propellant Storage Assembly design and analysis techniques. This paper summarizes the PTA design solution and discusses the underlying detailed analyses. In addition, design verification and qualification test activities are discussed.
Reliability Growth of Tactical Coolers at CMC Electronics Cincinnati: 1/5-Watt Cooler Test Report
NASA Astrophysics Data System (ADS)
Kuo, D. T.; Lody, T. D.
2004-06-01
CMC Electronics Cincinnati (CMC) is conducting a reliability growth program to extend the life of tactical Stirling-cycle cryocoolers. The continuous product improvement processes consist of testing production coolers to failure, determining the root cause, incorporating improvements and verification. The most recent life data for the 1/5-Watt Cooler (Model B512B) is presented with a discussion of leading root causes and potential improvements. The mean time to failure (MTTF) life of the coolers was found to be 22,552 hours with the root cause of failure attributed to the accumulation of methane and carbon dioxide in the cooler and the wear of the piston.
Durability evaluation of ceramic components using CARES/LIFE
NASA Technical Reports Server (NTRS)
Nemeth, Noel N.; Powers, Lynn M.; Janosik, Lesley A.; Gyekenyesi, John P.
1994-01-01
The computer program CARES/LIFE calculates the time-dependent reliability of monolithic ceramic components subjected to thermomechanical and/or proof test loading. This program is an extension of the CARES (Ceramics Analysis and Reliability Evaluation of Structures) computer program. CARES/LIFE accounts for the phenomenon of subcritical crack growth (SCG) by utilizing the power law, Paris law, or Walker equation. The two-parameter Weibull cumulative distribution function is used to characterize the variation in component strength. The effects of multiaxial stresses are modeled using either the principle of independent action (PIA), the Weibull normal stress averaging method (NSA), or the Batdorf theory. Inert strength and fatigue parameters are estimated from rupture strength data of naturally flawed specimens loaded in static, dynamic, or cyclic fatigue. Application of this design methodology is demonstrated using experimental data from alumina bar and disk flexure specimens which exhibit SCG when exposed to water.
Durability evaluation of ceramic components using CARES/LIFE
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nemeth, N.N.; Janosik, L.A.; Gyekenyesi, J.P.
1996-01-01
The computer program CARES/LIFE calculates the time-dependent reliability of monolithic ceramic components subjected to thermomechanical and/or proof test loading. This program is an extension of the CARES (Ceramics Analysis and Reliability Evaluation of Structures) computer program. CARES/LIFE accounts for the phenomenon of subcritical crack growth (SCG) by utilizing the power law, Paris law, or Walker equation. The two-parameter Weibull cumulative distribution function is used to characterize the variation in component strength. The effects of multiaxial stresses are modeled using either the principle of independent action (PIA), the Weibull normal stress averaging method (NSA), or the Batdorf theory. Inert strength andmore » fatigue parameters are estimated from rupture strength data of naturally flawed specimens loaded in static, dynamic, or cyclic fatigue. Application of this design methodology is demonstrated using experimental data from alumina bar and disk flexure specimens, which exhibit SCG when exposed to water.« less
NASA Technical Reports Server (NTRS)
Teverovsky, Alexander
2011-01-01
Presentation discusses: (1) Why Multi-Layer Ceramic Capacitors(MLCCs) crack during manual soldering? Workmanship and parts issues. (2) Do existing qualification requirements assure crack-free soldering? MIL-spec Thermal Shock (TS) testing. MIL-spec Resistance to Soldering Heat (RSH) test. (3) What test can assure reliable soldering? Mechanical characteristics of ceramics. Comparison of three TS techniques: LND, TSD, and IWT. (4) Simulation of TS conditions.
NASA Astrophysics Data System (ADS)
Johnson, Charles E.; Persinger, Randy R.; Lemon, James J.; Volkert, Keith J.
Comprehensive testing and monitoring approaches have been formulated and implemented for Intelsat VI, which is the largest commercial satellite in service. An account is given of the ground test program from unit level through launch site activities, giving attention to the test data handling system. Test methods unique to Intelsat VI encompass near-field anechoic chamber antenna measurements, offloading 1-g deployment of solar cell and deflector antennas, and electrostatic discharge measurements. The problems accruing to the sheer size of this spacecraft are stressed.
2015 Stewardship Science Academic Programs Annual
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stone, Terri; Mischo, Millicent
The Stockpile Stewardship Academic Programs (SSAP) are essential to maintaining a pipeline of professionals to support the technical capabilities that reside at the National Nuclear Security Administration (NNSA) national laboratories, sites, and plants. Since 1992, the United States has observed the moratorium on nuclear testing while significantly decreasing the nuclear arsenal. To accomplish this without nuclear testing, NNSA and its laboratories developed a science-based Stockpile Stewardship Program to maintain and enhance the experimental and computational tools required to ensure the continued safety, security, and reliability of the stockpile. NNSA launched its academic program portfolio more than a decade ago tomore » engage students skilled in specific technical areas of relevance to stockpile stewardship. The success of this program is reflected by the large number of SSAP students choosing to begin their careers at NNSA national laboratories.« less
Transit Reliability Information Program (TRIP) : Final Technical Report
DOT National Transportation Integrated Search
1984-05-01
The Transit Reliability Information Program (TRIP) is a government-initiated program to assist the transit industry in satisfying its need for rail transit car subsystem reliability information. TRIP provided this assistance through the operation of ...
Transit Reliability Information Program (TRIP) Phase I Report
DOT National Transportation Integrated Search
1981-06-01
The Transit Reliability Information Program (TRIP) is a government initiated program to assist the transit industry in satisfying its need for transit reliability information. TRIP provides this assistance through the operation of a national reliabil...
Free-piston Stirling engine/linear alternator 1000-hour endurance test
NASA Technical Reports Server (NTRS)
Rauch, J.; Dochat, G.
1985-01-01
The Free Piston Stirling Engine (FPSE) has the potential to be a long lived, highly reliable, power conversion device attractive for many product applications such as space, residential or remote site power. The purpose of endurance testing the FPSE was to demonstrate its potential for long life. The endurance program was directed at obtaining 1000 operational hours under various test conditions: low power, full stroke, duty cycle and stop/start. Critical performance parameters were measured to note any change and/or trend. Inspections were conducted to measure and compare critical seal/bearing clearances. The engine performed well throughout the program, completing more than 1100 hours. Hardware inspection, including the critical clearances, showed no significant change in hardware or clearance dimensions. The performance parameters did not exhibit any increasing or decreasing trends. The test program confirms the potential for long life FPSE applications.
NASA Technical Reports Server (NTRS)
Label, Kenneth A.
2017-01-01
NEPP Mission Statement: Provide NASA's leadership for developing and maintaining guidance for the screening, qualification, test, and reliable usage of electrical, electronic, and electromechanical (EEE) parts by NASA, in collaboration with other government Agencies and industry.
Engineering evaluation of SSME dynamic data from engine tests and SSV flights
NASA Technical Reports Server (NTRS)
1986-01-01
An engineering evaluation of dynamic data from SSME hot firing tests and SSV flights is summarized. The basic objective of the study is to provide analyses of vibration, strain and dynamic pressure measurements in support of MSFC performance and reliability improvement programs. A brief description of the SSME test program is given and a typical test evaluation cycle reviewed. Data banks generated to characterize SSME component dynamic characteristics are described and statistical analyses performed on these data base measurements are discussed. Analytical models applied to define the dynamic behavior of SSME components (such as turbopump bearing elements and the flight accelerometer safety cut-off system) are also summarized. Appendices are included to illustrate some typical tasks performed under this study.
Next-generation avionics packaging and cooling 'test results from a prototype system'
NASA Astrophysics Data System (ADS)
Seals, J. D.
The author reports on the design, material characteristics, and test results obtained under the US Air Force's advanced aircraft avionics packaging technologies (AAAPT) program, whose charter is to investigate new designs and technologies for reliable packaging, interconnection, and thermal management. Under this program, AT&T Bell Laboratories has completed the preliminary testing of and is evaluating a number of promising materials and technologies, including conformal encapsulation, liquid flow-through cooling, and a cyanate ester backplane. A fifty-two module system incorporating these and and other technologies has undergone preliminary cooling efficiency, shock, sine and random vibration, and maintenance testing. One of the primary objectives was to evaluate the interaction compatibility of new materials and designs with other components in the system.
Update on MTTF figures for linear and rotary coolers of Thales Cryogenics
NASA Astrophysics Data System (ADS)
van de Groep, W.; van der Weijden, H.; van Leeuwen, R.; Benschop, T.; Cauquil, J. M.; Griot, R.
2012-06-01
Thales Cryogenics has an extensive background in delivering linear and rotary coolers for military, civil and space programs. During the last years several technical improvements have increased the lifetime of all Thales coolers resulting in significantly higher Mean Time To Failure (MTTF) figures. In this paper not only updated MTTF values for most of the products in our portfolio will be presented but also the methodology used to come to these reliability figures will be explained. The differences between rotary and linear coolers will be highlighted including the different failure modes influencing the lifetime under operational conditions. These updated reliability figures are based on extensive test results for both rotary and linear coolers as well as Weibull analysis, failure mode identifications, various types of lifetime testing and field results of operational coolers. The impact of the cooler selection for typical applications will be outlined. This updated reliability approach will enable an improved tradeoff for cooler selection in applications where MTTF and a correct reliability assessment is key. Improbing on cooler selection and an increased insight in cooler reliability will result in a higher uptime and operability of equipment, less risk on unexpected failures and lower costs of ownership.
Generalized Symbolic Execution for Model Checking and Testing
NASA Technical Reports Server (NTRS)
Khurshid, Sarfraz; Pasareanu, Corina; Visser, Willem; Kofmeyer, David (Technical Monitor)
2003-01-01
Modern software systems, which often are concurrent and manipulate complex data structures must be extremely reliable. We present a novel framework based on symbolic execution, for automated checking of such systems. We provide a two-fold generalization of traditional symbolic execution based approaches: one, we define a program instrumentation, which enables standard model checkers to perform symbolic execution; two, we give a novel symbolic execution algorithm that handles dynamically allocated structures (e.g., lists and trees), method preconditions (e.g., acyclicity of lists), data (e.g., integers and strings) and concurrency. The program instrumentation enables a model checker to automatically explore program heap configurations (using a systematic treatment of aliasing) and manipulate logical formulae on program data values (using a decision procedure). We illustrate two applications of our framework: checking correctness of multi-threaded programs that take inputs from unbounded domains with complex structure and generation of non-isomorphic test inputs that satisfy a testing criterion. Our implementation for Java uses the Java PathFinder model checker.
Shuttle/Agena study. Annex A: Ascent agena configuration
NASA Technical Reports Server (NTRS)
1972-01-01
Details are presented on the Agena rocket vehicle description, vehicle interfaces, environmental constraints and test requirements, software programs, and ground support equipment. The basic design concept for the Ascent Agena is identified as optimization of reliability, flexibility, performance capabilities, and economy through the use of tested and flight-proven hardware. The development history of the Agenas A, B, and D is outlined and space applications are described.
EBR-II high-ramp transients under computer control
DOE Office of Scientific and Technical Information (OSTI.GOV)
Forrester, R.J.; Larson, H.A.; Christensen, L.J.
1983-01-01
During reactor run 122, EBR-II was subjected to 13 computer-controlled overpower transients at ramps of 4 MWt/s to qualify the facility and fuel for transient testing of LMFBR oxide fuels as part of the EBR-II operational-reliability-testing (ORT) program. A computer-controlled automatic control-rod drive system (ACRDS), designed by EBR-II personnel, permitted automatic control on demand power during the transients.
An Overview of NASA Automotive Component Reliability Studies
NASA Technical Reports Server (NTRS)
Sampson, Michael J.
2016-01-01
The results of NASAs studies into the appropriateness of using US Automotive electronic parts in NASA spaceflight systems will be presented. The first part of the presentation provides an overview of the United States Automotive Electronics Councils AECQ standardization program, the second part provides a summary of the results of NASAs procurement and testing experiences and other lessons learned along with preliminary test results.
An Overview Of NASA Automotive Component Reliability Studies
NASA Technical Reports Server (NTRS)
Sampson, Michael J.
2016-01-01
The results of NASAs studies into the appropriateness of using US Automotive electronic parts in NASA spaceflight systems will be presented. The first part of the presentation provides an overview of the United States Automotive Electronics Councils AECQ standardization program, the second part provides a summary of the results of NASAs procurement and testing experiences and other lessons learned along with preliminary test results.
Halbach Magnetic Rotor Development
NASA Technical Reports Server (NTRS)
Gallo, Christopher A.
2008-01-01
The NASA John H. Glenn Research Center has a wealth of experience in Halbach array technology through the Fundamental Aeronautics Program. The goals of the program include improving aircraft efficiency, reliability, and safety. The concept of a Halbach magnetically levitated electric aircraft motor will help reduce harmful emissions, reduce the Nation s dependence on fossil fuels, increase efficiency and reliability, reduce maintenance and decrease operating noise levels. Experimental hardware systems were developed in the GRC Engineering Development Division to validate the basic principles described herein and the theoretical work that was performed. A number of Halbach Magnetic rotors have been developed and tested under this program. A separate test hardware setup was developed to characterize each of the rotors. A second hardware setup was developed to test the levitation characteristics of the rotors. Each system focused around a unique Halbach array rotor. Each rotor required original design and fabrication techniques. A 4 in. diameter rotor was developed to test the radial levitation effects for use as a magnetic bearing. To show scalability from the 4 in. rotor, a 1 in. rotor was developed to also test radial levitation effects. The next rotor to be developed was 20 in. in diameter again to show scalability from the 4 in. rotor. An axial rotor was developed to determine the force that could be generated to position the rotor axially while it is rotating. With both radial and axial magnetic bearings, the rotor would be completely suspended magnetically. The purpose of this report is to document the development of a series of Halbach magnetic rotors to be used in testing. The design, fabrication and assembly of the rotors will be discussed as well as the hardware developed to test the rotors.
Bruce, Jared; Echemendia, Ruben; Tangeman, Lindy; Meeuwisse, Willem; Comper, Paul; Hutchison, Michael; Aubry, Mark
2016-01-01
Computerized neuropsychological tests are frequently used to assist in return-to-play decisions following sports concussion. However, due to concerns about test reliability, the Centers for Disease Control and Prevention recommends yearly baseline testing. The standard practice that has developed in baseline/postinjury comparisons is to examine the difference between the most recent baseline test and postconcussion performance. Drawing from classical test theory, the present study investigated whether temporal stability could be improved by taking an alternate approach that uses the aggregate of 2 baselines to more accurately estimate baseline cognitive ability. One hundred fifteen English-speaking professional hockey players with 3 consecutive Immediate Postconcussion Assessment and Testing (ImPACT) baseline tests were extracted from a clinical program evaluation database overseen by the National Hockey League and National Hockey League Players' Association. The temporal stability of ImPACT composite scores was significantly increased by aggregating test performance during Sessions 1 and 2 to predict performance during Session 3. Using this approach, the 2-factor Memory (r = .72) and Speed (r = .79) composites of ImPACT showed acceptable long-term reliability. Using the aggregate of 2 baseline scores significantly improves temporal stability and allows for more accurate predictions of cognitive change following concussion. Clinicians are encouraged to estimate baseline abilities by taking into account all of an athlete's previous baseline scores.
Validity of instruments to assess students' travel and pedestrian safety.
Mendoza, Jason A; Watson, Kathy; Baranowski, Tom; Nicklas, Theresa A; Uscanga, Doris K; Hanfling, Marcus J
2010-05-18
Safe Routes to School (SRTS) programs are designed to make walking and bicycling to school safe and accessible for children. Despite their growing popularity, few validated measures exist for assessing important outcomes such as type of student transport or pedestrian safety behaviors. This research validated the SRTS school travel survey and a pedestrian safety behavior checklist. Fourth grade students completed a brief written survey on how they got to school that day with set responses. Test-retest reliability was obtained 3-4 hours apart. Convergent validity of the SRTS travel survey was assessed by comparison to parents' report. For the measure of pedestrian safety behavior, 10 research assistants observed 29 students at a school intersection for completion of 8 selected pedestrian safety behaviors. Reliability was determined in two ways: correlations between the research assistants' ratings to that of the Principal Investigator (PI) and intraclass correlations (ICC) across research assistant ratings. The SRTS travel survey had high test-retest reliability (kappa = 0.97, n = 96, p < 0.001) and convergent validity (kappa = 0.87, n = 81, p < 0.001). The pedestrian safety behavior checklist had moderate reliability across research assistants' ratings (ICC = 0.48) and moderate correlation with the PI (r = 0.55, p = < 0.01). When two raters simultaneously used the instrument, the ICC increased to 0.65. Overall percent agreement (91%), sensitivity (85%) and specificity (83%) were acceptable. These validated instruments can be used to assess SRTS programs. The pedestrian safety behavior checklist may benefit from further formative work.
Accuracy and reliability of peer assessment of athletic training psychomotor laboratory skills.
Marty, Melissa C; Henning, Jolene M; Willse, John T
2010-01-01
Peer assessment is defined as students judging the level or quality of a fellow student's understanding. No researchers have yet demonstrated the accuracy or reliability of peer assessment in athletic training education. To determine the accuracy and reliability of peer assessment of athletic training students' psychomotor skills. Cross-sectional study. Entry-level master's athletic training education program. First-year (n = 5) and second-year (n = 8) students. Participants evaluated 10 videos of a peer performing 3 psychomotor skills (middle deltoid manual muscle test, Faber test, and Slocum drawer test) on 2 separate occasions using a valid assessment tool. Accuracy of each peer-assessment score was examined through percentage correct scores. We used a generalizability study to determine how reliable athletic training students were in assessing a peer performing the aforementioned skills. Decision studies using generalizability theory demonstrated how the peer-assessment scores were affected by the number of participants and number of occasions. Participants had a high percentage of correct scores: 96.84% for the middle deltoid manual muscle test, 94.83% for the Faber test, and 97.13% for the Slocum drawer test. They were not able to reliably assess a peer performing any of the psychomotor skills on only 1 occasion. However, the φ increased (exceeding the 0.70 minimal standard) when 2 participants assessed the skill on 3 occasions (φ = 0.79) for the Faber test, with 1 participant on 2 occasions (φ = 0.76) for the Slocum drawer test, and with 3 participants on 2 occasions for the middle deltoid manual muscle test (φ = 0.72). Although students did not detect all errors, they assessed their peers with an average of 96% accuracy. Having only 1 student assess a peer performing certain psychomotor skills was less reliable than having more than 1 student assess those skills on more than 1 occasion. Peer assessment of psychomotor skills could be an important part of the learning process and a tool to supplement instructor assessment.
DiClemente, Carlo C; Crouch, Taylor Berens; Norwood, Amber E Q; Delahanty, Janine; Welsh, Christopher
2015-03-01
Screening, brief intervention, and referral to treatment (SBIRT) has become an empirically supported and widely implemented approach in primary and specialty care for addressing substance misuse. Accordingly, training of providers in SBIRT has increased exponentially in recent years. However, the quality and fidelity of training programs and subsequent interventions are largely unknown because of the lack of SBIRT-specific evaluation tools. The purpose of this study was to create a coding scale to assess quality and fidelity of SBIRT interactions addressing alcohol, tobacco, illicit drugs, and prescription medication misuse. The scale was developed to evaluate performance in an SBIRT residency training program. Scale development was based on training protocol and competencies with consultation from Motivational Interviewing coding experts. Trained medical residents practiced SBIRT with standardized patients during 10- to 15-min videotaped interactions. This study included 25 tapes from the Family Medicine program coded by 3 unique coder pairs with varying levels of coding experience. Interrater reliability was assessed for overall scale components and individual items via intraclass correlation coefficients. Coder pair-specific reliability was also assessed. Interrater reliability was excellent overall for the scale components (>.85) and nearly all items. Reliability was higher for more experienced coders, though still adequate for the trained coder pair. Descriptive data demonstrated a broad range of adherence and skills. Subscale correlations supported concurrent and discriminant validity. Data provide evidence that the MD3 SBIRT Coding Scale is a psychometrically reliable coding system for evaluating SBIRT interactions and can be used to evaluate implementation skills for fidelity, training, assessment, and research. Recommendations for refinement and further testing of the measure are discussed. (PsycINFO Database Record (c) 2015 APA, all rights reserved).
RELAV - RELIABILITY/AVAILABILITY ANALYSIS PROGRAM
NASA Technical Reports Server (NTRS)
Bowerman, P. N.
1994-01-01
RELAV (Reliability/Availability Analysis Program) is a comprehensive analytical tool to determine the reliability or availability of any general system which can be modeled as embedded k-out-of-n groups of items (components) and/or subgroups. Both ground and flight systems at NASA's Jet Propulsion Laboratory have utilized this program. RELAV can assess current system performance during the later testing phases of a system design, as well as model candidate designs/architectures or validate and form predictions during the early phases of a design. Systems are commonly modeled as System Block Diagrams (SBDs). RELAV calculates the success probability of each group of items and/or subgroups within the system assuming k-out-of-n operating rules apply for each group. The program operates on a folding basis; i.e. it works its way towards the system level from the most embedded level by folding related groups into single components. The entire folding process involves probabilities; therefore, availability problems are performed in terms of the probability of success, and reliability problems are performed for specific mission lengths. An enhanced cumulative binomial algorithm is used for groups where all probabilities are equal, while a fast algorithm based upon "Computing k-out-of-n System Reliability", Barlow & Heidtmann, IEEE TRANSACTIONS ON RELIABILITY, October 1984, is used for groups with unequal probabilities. Inputs to the program include a description of the system and any one of the following: 1) availabilities of the items, 2) mean time between failures and mean time to repairs for the items from which availabilities are calculated, 3) mean time between failures and mission length(s) from which reliabilities are calculated, or 4) failure rates and mission length(s) from which reliabilities are calculated. The results are probabilities of success of each group and the system in the given configuration. RELAV assumes exponential failure distributions for reliability calculations and infinite repair resources for availability calculations. No more than 967 items or groups can be modeled by RELAV. If larger problems can be broken into subsystems of 967 items or less, the subsystem results can be used as item inputs to a system problem. The calculated availabilities are steady-state values. Group results are presented in the order in which they were calculated (from the most embedded level out to the system level). This provides a good mechanism to perform trade studies. Starting from the system result and working backwards, the granularity gets finer; therefore, system elements that contribute most to system degradation are detected quickly. RELAV is a C-language program originally developed under the UNIX operating system on a MASSCOMP MC500 computer. It has been modified, as necessary, and ported to an IBM PC compatible with a math coprocessor. The current version of the program runs in the DOS environment and requires a Turbo C vers. 2.0 compiler. RELAV has a memory requirement of 103 KB and was developed in 1989. RELAV is a copyrighted work with all copyright vested in NASA.
Safety, reliability, maintainability and quality provisions for the Space Shuttle program
NASA Technical Reports Server (NTRS)
1990-01-01
This publication establishes common safety, reliability, maintainability and quality provisions for the Space Shuttle Program. NASA Centers shall use this publication both as the basis for negotiating safety, reliability, maintainability and quality requirements with Shuttle Program contractors and as the guideline for conduct of program safety, reliability, maintainability and quality activities at the Centers. Centers shall assure that applicable provisions of the publication are imposed in lower tier contracts. Centers shall give due regard to other Space Shuttle Program planning in order to provide an integrated total Space Shuttle Program activity. In the implementation of safety, reliability, maintainability and quality activities, consideration shall be given to hardware complexity, supplier experience, state of hardware development, unit cost, and hardware use. The approach and methods for contractor implementation shall be described in the contractors safety, reliability, maintainability and quality plans. This publication incorporates provisions of NASA documents: NHB 1700.1 'NASA Safety Manual, Vol. 1'; NHB 5300.4(IA), 'Reliability Program Provisions for Aeronautical and Space System Contractors'; and NHB 5300.4(1B), 'Quality Program Provisions for Aeronautical and Space System Contractors'. It has been tailored from the above documents based on experience in other programs. It is intended that this publication be reviewed and revised, as appropriate, to reflect new experience and to assure continuing viability.
Nevada National Security Site Groundwater Program
None
2018-01-16
From 1951 to 1992, the Unites States government conducted 828 underground nuclear tests at the Nevada National Security Site. About one-third of these tests occurred near, below or within the water table - the very top portion of the groundwater layer where rock and soil are completely saturated with water. As a result, some groundwater was contaminated. The U.S. Department of Energy (DOE) began exploring the effects of groundwater contamination in the 1970s. Though contamination from underground testing has never been detected on public land, the DOE was committed to developing an advanced, reliable monitoring network that ensures the long-term protection of the public. An intensive groundwater investigation program was launched in 1989.
The case against compulsory casefinding in controlling AIDS--testing, screening and reporting.
Gostin, L O; Curran, W J; Clark, M E
1987-01-01
The spread of acquired immune deficiency syndrome (AIDS) demands a comprehensive and effective public health response. Because no treatment or vaccine is currently available, traditional infection control measures are being considered. Proposals include compulsory testing and screening of selected high risk populations. The fairness and accuracy of compulsory screening programs depend upon the reliability of medical technology and the balancing of public health and individual confidentiality interests. This Article proposes criteria for evaluating compulsory testing and screening programs. It concludes that voluntary identification, education, and counselling of infected persons is the most effective means of encouraging the behavioral changes that are necessary to halt the spread of AIDS.
Test data from small solid propellant rocket motor plume measurements (FA-21)
NASA Technical Reports Server (NTRS)
Hair, L. M.; Somers, R. E.
1976-01-01
A program is described for obtaining a reliable, parametric set of measurements in the exhaust plumes of solid propellant rocket motors. Plume measurements included pressures, temperatures, forces, heat transfer rates, particle sampling, and high-speed movies. Approximately 210,000 digital data points and 15,000 movie frames were acquired. Measurements were made at points in the plumes via rake-mounted probes, and on the surface of a large plate impinged by the exhaust plume. Parametric variations were made in pressure altitude, propellant aluminum loading, impinged plate incidence angle and distance from nozzle exit to plate or rake. Reliability was incorporated by continual use of repeat runs. The test setup of the various hardware items is described along with an account of test procedures. Test results and data accuracy are discussed. Format of the data presentation is detailed. Complete data are included in the appendix.
Innovations in dynamic test restraint systems
NASA Technical Reports Server (NTRS)
Fuld, Christopher J.
1990-01-01
Recent launch system development programs have led to a new generation of large scale dynamic tests. The variety of test scenarios share one common requirement: restrain and capture massive high velocity flight hardware with no structural damage. The Space Systems Lab of McDonnell Douglas developed a remarkably simple and cost effective approach to such testing using ripstitch energy absorbers adapted from the sport of technical rockclimbing. The proven system reliability of the capture system concept has led to a wide variety of applications in test system design and in aerospace hardware design.
Spinal cord testing: auditing for quality assurance.
Marr, J A; Reid, B
1991-04-01
A quality assurance audit of spinal cord testing as documented by staff nurses was carried out. Twenty-five patient records were examined for accuracy of documented testing and compared to assessments performed by three investigators. A pilot study established interrater reliability of a tool that was designed especially for this study. Results indicated staff nurses failed to meet pre-established 100% standard in all categories of testing when compared with investigator's findings. Possible reasons for this disparity are discussed as well as indications for modifications in the spinal testing record, teaching program and preset standards.
E-Service Quality Evaluation on E-Government Website: Case Study BPJS Kesehatan Indonesia
NASA Astrophysics Data System (ADS)
Rasyid, A.; Alfina, I.
2017-01-01
This research intends to develop a model to evaluate the quality of e-services on e-government. The proposed model consists of seven dimensions: web design, reliability, responsiveness, privacy and security, personalization, information, and ease of use. The model is used to measure the quality of the e-registration of BPJS Kesehatan, an Indonesian government health insurance program. The validation and reliability testing show that of the seven dimensions proposed, only four that suitable for the case study. The result shows that the BPJS Kesehatan e-registration service is good in reliability and responsiveness dimensions, while from web design and ease of use dimensions the e-service still needs to be optimized.
Design, fabrication and testing of porous tungsten vaporizers for mercury ion thrusters
NASA Technical Reports Server (NTRS)
Zavesky, R.; Kroeger, E.; Kami, S.
1983-01-01
The dispersions in the characteristics, performance and reliability of vaporizers for early model 30-cm thrusters were investigated. The purpose of the paper is to explore the findings and to discuss the approaches that were taken to reduce the observed dispersion and present the results of a program which validated those approaches. The information that is presented includes porous tungsten materials specifications, a discussion of assembly procedures, and a description of a test program which screens both material and fabrication processes. There are five appendices providing additional detail in the areas of vaporizer contamination, nitrogen flow testing, bubble testing, porosimeter testing, and mercury purity. Four neutralizers, seven cathodes and five main vaporizers were successfully fabricated, tested, and operated on thrusters. Performance data from those devices is presented and indicates extremely repeatable results from using the design and fabrication procedures.
Barab, S A; Redman, B K; Froman, R D
1998-01-01
The Level of Institutionalization (LoIn) scales were developed to assess the extent to which a health promotion program has become integrated into a health care organization. The instrument was designed specifically to measure the amount of routinization and niche saturation of four subsystems (production, maintenance, supportive, and managerial) believed to make up an organization. In this study, the LoIn scales were completed for diabetes programs in 102 general hospitals and 30 home health agencies in Maryland and Pennsylvania. Reliability estimates across the four subsystems for routines (alpha = .61) and for niche saturation (alpha = .44) were substandard. Average correlation among the four subsystems for routines was .67, and among the four subsystems for niche saturation was .38, indicating moderate to large amounts of shared variance among subsystems and challenging claims of discriminant validity. Given these large correlations and a poor fit when testing the eight-factor model, higher-order confirmatory factor analyses were carried out. Results supported the existence of two second-order factors. When collapsed into two factors, the reliabilities were adequate (routines alpha = .90; niche saturation alpha = .80). Criterion-related validity also was found between length of program existence and the routine factor.
Sonar Transducer Reliability Improvement Program (STRIP) FY80.
1980-07-01
heating element powered by a temperature conLroller (YSI model 74) with a series 400 thermistor probe. Figure 3.1 shows the data and average curves...ATTACHMENT METHODS General Welded Receptacles Threaded or Bolted Receptacles Elastomeric Bonded Receptacles I I!11 " SECTION 12 - CABLE HARNESS TEST
Sandia National Laboratories: Fabrication, Testing and Validation
; Technology Defense Systems & Assessments About Defense Systems & Assessments Program Areas safe, secure, reliable, and can fully support the Nation's deterrence policy. Employing only the most support of this mission, Sandia National Laboratories has a significant role in advancing the "state
Final Report of the Vocational Assessment Project, 1979-80.
ERIC Educational Resources Information Center
Rutgers, The State Univ., New Brunswick, NJ. School of Medicine.
To improve vocational rehabilitation programs for schizophrenic persons, a project sought to design an effective assessment strategy. Inactive records of schizophrenic clients at New Jersey sheltered workshops were examined to determine validity and reliability of assessment instruments being used. General Aptitude Test Battery (GATB) profiles of…
United States Air Force Graduate Student Summer Support Program 1986. Program Management Report
1986-12-01
ng cond iaorns. -: i s ; L s : & i ;al Ii i t r-Lk...reliable technique for obtaining confidence intervals for the population correlation under most selection situations. 197 I . I I .. AN ANALYSIS .r...colIlected Over’ tie. Six analyses were evaiyaterd an ~d sc:me were tested fr effective u.se in :,rilire v-ea It i we aral i s . Recoririlendat i :.ris
High resolution microwave spectrometer sounder (HIMSS), volume 1, book 1
NASA Technical Reports Server (NTRS)
1990-01-01
The following topics are presented with respect to the high resolution microwave spectrometer sounder (HIMSS) that is to be used as an instrument for NASA's Earth Observing System (EOS): (1) an instrument overview; (2) an instrument description; (3) the instrument's conceptual design; (4) technical risks and offsets; (5) instrument reliability; (6) commands and telemetry; (7) mass and power budgets; (8) integration and test program; (9) program implementation; and (10) phase CD schedule.
Guo, Yi; Bian, Jiang; Leavitt, Trevor; Vincent, Heather K; Vander Zalm, Lindsey; Teurlings, Tyler L; Smith, Megan D; Modave, François
2017-03-07
Regular physical activity can not only help with weight management, but also lower cardiovascular risks, cancer rates, and chronic disease burden. Yet, only approximately 20% of Americans currently meet the physical activity guidelines recommended by the US Department of Health and Human Services. With the rapid development of mobile technologies, mobile apps have the potential to improve participation rates in exercise programs, particularly if they are evidence-based and are of sufficient content quality. The goal of this study was to develop and test an instrument, which was designed to score the content quality of exercise program apps with respect to the exercise guidelines set forth by the American College of Sports Medicine (ACSM). We conducted two focus groups (N=14) to elicit input for developing a preliminary 27-item scoring instruments based on the ACSM exercise prescription guidelines. Three reviewers who were no sports medicine experts independently scored 28 exercise program apps using the instrument. Inter- and intra-rater reliability was assessed among the 3 reviewers. An expert reviewer, a Fellow of the ACSM, also scored the 28 apps to create criterion scores. Criterion validity was assessed by comparing nonexpert reviewers' scores to the criterion scores. Overall, inter- and intra-rater reliability was high with most coefficients being greater than .7. Inter-rater reliability coefficients ranged from .59 to .99, and intra-rater reliability coefficients ranged from .47 to 1.00. All reliability coefficients were statistically significant. Criterion validity was found to be excellent, with the weighted kappa statistics ranging from .67 to .99, indicating a substantial agreement between the scores of expert and nonexpert reviewers. Finally, all apps scored poorly against the ACSM exercise prescription guidelines. None of the apps received a score greater than 35, out of a possible maximal score of 70. We have developed and presented valid and reliable scoring instruments for exercise program apps. Our instrument may be useful for consumers and health care providers who are looking for apps that provide safe, progressive general exercise programs for health and fitness. ©Yi Guo, Jiang Bian, Trevor Leavitt, Heather K Vincent, Lindsey Vander Zalm, Tyler L Teurlings, Megan D Smith, François Modave. Originally published in the Journal of Medical Internet Research (http://www.jmir.org), 07.03.2017.
Black, Anne C; Serowik, Kristin L; Ablondi, Karen M; Rosen, Marc I
2013-01-01
The need for accurate and reliable information about income and resources available to individuals with psychiatric disabilities is critical for the assessment of need and evaluation of programs designed to alleviate financial hardship or affect finance allocation. Measurement of finances is ubiquitous in studies of economics, poverty, and social services. However, evidence has demonstrated that these measures often contain error. We compare the 1-week test-retest reliability of income and finance data from 24 adult psychiatric outpatients using assessment-as-usual (AAU) and a new instrument, the Timeline Historical Review of Income and Financial Transactions (THRIFT). Reliability estimates obtained with the THRIFT for Income (0.77), Expenses (0.91), and Debt (0.99) domains were significantly better than those obtained with AAU. Reliability estimates for Balance did not differ. THRIFT reduced measurement error and provided more reliable information than AAU for assessment of personal finances in psychiatric patients receiving Social Security benefits. The instrument also may be useful with other low-income groups.
Structural Testing of the Blade Reliability Collaborative Effect of Defect Wind Turbine Blades
DOE Office of Scientific and Technical Information (OSTI.GOV)
Desmond, M.; Hughes, S.; Paquette, J.
Two 8.3-meter (m) wind turbine blades intentionally constructed with manufacturing flaws were tested to failure at the National Wind Technology Center (NWTC) at the National Renewable Energy Laboratory (NREL) south of Boulder, Colorado. Two blades were tested; one blade was manufactured with a fiberglass spar cap and the second blade was manufactured with a carbon fiber spar cap. Test loading primarily consisted of flap fatigue loading of the blades, with one quasi-static ultimate load case applied to the carbon fiber spar cap blade. Results of the test program were intended to provide the full-scale test data needed for validation ofmore » model and coupon test results of the effect of defects in wind turbine blade composite materials. Testing was part of the Blade Reliability Collaborative (BRC) led by Sandia National Laboratories (SNL). The BRC seeks to develop a deeper understanding of the causes of unexpected blade failures (Paquette 2012), and to develop methods to enable blades to survive to their expected operational lifetime. Recent work in the BRC includes examining and characterizing flaws and defects known to exist in wind turbine blades from manufacturing processes (Riddle et al. 2011). Recent results from reliability databases show that wind turbine rotor blades continue to be a leading contributor to turbine downtime (Paquette 2012).« less
The development of data acquisition and processing application system for RF ion source
NASA Astrophysics Data System (ADS)
Zhang, Xiaodan; Wang, Xiaoying; Hu, Chundong; Jiang, Caichao; Xie, Yahong; Zhao, Yuanzhe
2017-07-01
As the key ion source component of nuclear fusion auxiliary heating devices, the radio frequency (RF) ion source is developed and applied gradually to offer a source plasma with the advantages of ease of control and high reliability. In addition, it easily achieves long-pulse steady-state operation. During the process of the development and testing of the RF ion source, a lot of original experimental data will be generated. Therefore, it is necessary to develop a stable and reliable computer data acquisition and processing application system for realizing the functions of data acquisition, storage, access, and real-time monitoring. In this paper, the development of a data acquisition and processing application system for the RF ion source is presented. The hardware platform is based on the PXI system and the software is programmed on the LabVIEW development environment. The key technologies that are used for the implementation of this software programming mainly include the long-pulse data acquisition technology, multi-threading processing technology, transmission control communication protocol, and the Lempel-Ziv-Oberhumer data compression algorithm. Now, this design has been tested and applied on the RF ion source. The test results show that it can work reliably and steadily. With the help of this design, the stable plasma discharge data of the RF ion source are collected, stored, accessed, and monitored in real-time. It is shown that it has a very practical application significance for the RF experiments.
Kim, Hannah; Ricketts, Todd A
2013-01-01
To investigate the test-retest reliability of real-ear aided response (REAR) measures in open and closed hearing aid fittings in children using appropriate probe-microphone calibration techniques (stored equalization for open fittings and concurrent equalization for closed fittings). Probe-microphone measurements were completed for two mini-behind-the-ear (BTE) hearing aids which were coupled to the ear using open and closed eartips via thin (0.9 mm) tubing. Before probe-microphone testing, the gain of each of the test hearing aids was programmed using an artificial ear simulator (IEC 711) and a Knowles Electronic Manikin for Acoustic Research to match the National Acoustic Laboratories-Non-Linear, version 1 targets for one of two separate hearing loss configurations using an Audioscan Verifit. No further adjustments were made, and the same amplifier gain was used within each hearing aid across both eartip configurations and all participants. Probe-microphone testing included real-ear occluded response (REOR) and REAR measures using the Verifit's standard speech signal (the carrot passage) presented at 65 dB sound pressure level (SPL). Two repeated probe-microphone measures were made for each participant with the probe-tube and hearing aid removed and repositioned between each trial in order to assess intrasubject measurement variability. These procedures were repeated using both open and closed domes. Thirty-two children, ages ranging from 4 to 14 yr. The test-retest standard deviations for open and closed measures did not exceed 4 dB at any frequency. There was also no significant difference between the open (stored equalization) and closed (concurrent equalization) methods. Reliability was particularly similar in the high frequencies and was also quite similar to that reported in previous research. There was no correlation between reliability and age, suggesting high reliability across all ages evaluated. The findings from this study suggest that reliable probe-microphone measurements are obtainable on children 4 yr and older for both traditional unvented and open-canal hearing aid fittings. These data suggest that clinicians should not avoid fitting open technology to children as young as 4 y because of concerns regarding the reliability of verification techniques. American Academy of Audiology.
An overview of fatigue failures at the Rocky Flats Wind System Test Center
NASA Technical Reports Server (NTRS)
Waldon, C. A.
1981-01-01
Potential small wind energy conversion (SWECS) design problems were identified to improve product quality and reliability. Mass produced components such as gearboxes, generators, bearings, etc., are generally reliable due to their widespread uniform use in other industries. The likelihood of failure increases, though, in the interfacing of these components and in SWECS components designed for a specific system use. Problems relating to the structural integrity of such components are discussed and analyzed with techniques currently used in quality assurance programs in other manufacturing industries.
Wilson, Deborah E.
2011-01-01
The events and aftermath of September 11, 2001, accelerated a search for personnel reliability test measures to identify individuals who could pose a threat to our nation's security and safety. The creation and administration of a behavioral health screen for BSL-4 laboratory workers at the National Institutes of Health represents a pioneering effort to proactively build a BSL-4 safety culture promoting worker cohesiveness, trust, respect, and reliability with a balance of worker privacy and public safety. PMID:21361798
DOE Office of Scientific and Technical Information (OSTI.GOV)
Braatz, Brett G.; Cumblidge, Stephen E.; Doctor, Steven R.
2012-12-31
The U.S. Nuclear Regulatory Commission has established the Program to Assess the Reliability of Emerging Nondestructive Techniques (PARENT) as a follow-on to the international cooperative Program for the Inspection of Nickel Alloy Components (PINC). The goal of PINC was to evaluate the capabilities of various nondestructive evaluation (NDE) techniques to detect and characterize surface-breaking primary water stress corrosion cracks in dissimilar-metal welds (DMW) in bottom-mounted instrumentation (BMI) penetrations and small-bore (≈400-mm diameter) piping components. A series of international blind round-robin tests were conducted by commercial and university inspection teams. Results from these tests showed that a combination of conventional andmore » phased-array ultrasound techniques provided the highest performance for flaw detection and depth sizing in dissimilar metal piping welds. The effective detection of flaws in BMIs by eddy current and ultrasound shows that it may be possible to reliably inspect these components in the field. The goal of PARENT is to continue the work begun in PINC and apply the lessons learned to a series of open and blind international round-robin tests that will be conducted on a new set of piping components including large-bore (≈900-mm diameter) DMWs, small-bore DMWs, and BMIs. Open round-robin testing will engage universities and industry worldwide to investigate the reliability of emerging NDE techniques to detect and accurately size flaws having a wide range of lengths, depths, orientations, and locations. Blind round-robin testing will invite testing organizations worldwide, whose inspectors and procedures are certified by the standards for the nuclear industry in their respective countries, to investigate the ability of established NDE techniques to detect and size flaws whose characteristics range from easy to very difficult to detect and size. This paper presents highlights of PINC and reports on the plans and progress for PARENT round-robin tests.« less
Validation of the German version of the Ford Insomnia Response to Stress Test.
Dieck, Arne; Helbig, Susanne; Drake, Christopher L; Backhaus, Jutta
2018-06-01
The purpose of this study was to assess the psychometric properties of a German version of the Ford Insomnia Response to Stress Test with groups with and without sleep problems. Three studies were analysed. Data set 1 was based on an initial screening for a sleep training program (n = 393), data set 2 was based on a study to test the test-retest reliability of the Ford Insomnia Response to Stress Test (n = 284) and data set 3 was based on a study to examine the influence of competitive sport on sleep (n = 37). Data sets 1 and 2 were used to test internal consistency, factor structure, convergent validity, discriminant validity and test-retest reliability of the Ford Insomnia Response to Stress Test. Content validity was tested using data set 3. Cronbach's alpha of the Ford Insomnia Response to Stress Test was good (α = 0.80) and test-retest reliability was satisfactory (r = 0.72). Overall, the one-factor model showed the best fit. Furthermore, significant positive correlations between the Ford Insomnia Response to Stress Test and impaired sleep quality, depression and stress reactivity were in line with the expectations regarding the convergent validity. Subjects with sleep problems had significantly higher scores in the Ford Insomnia Response to Stress Test than subjects without sleep problems (P < 0.01). Competitive athletes with higher scores in the Ford Insomnia Response to Stress Test had significantly lower sleep quality (P = 0.01), demonstrating that vulnerability for stress-induced sleep disturbances accompanies poorer sleep quality in stressful episodes. The findings show that the German version of the Ford Insomnia Response to Stress Test is a reliable and valid questionnaire to assess the vulnerability to stress-induced sleep disturbances. © 2017 European Sleep Research Society.
Composite Overwrapped Pressure Vessels (COPV): Flight Rationale for the Space Shuttle Program
NASA Technical Reports Server (NTRS)
Kezirian, Michael T.; Johnson, Kevin L.; Phoenix, Stuart L.
2011-01-01
Each Orbiter Vehicle (Space Shuttle Program) contains up to 24 Kevlar49/Epoxy Composite Overwrapped Pressure Vessels (COPV) for storage of pressurized gases. In the wake of the Columbia accident and the ensuing Return To Flight (RTF) activities, Orbiter engineers reexamined COPV flight certification. The original COPV design calculations were updated to include recently declassified Kevlar COPV test data from Lawrence Livermore National Laboratory (LLNL) and to incorporate changes in how the Space Shuttle was operated as opposed to orinigially envisioned. 2005 estimates for the probability of a catastrophic failure over the life of the program (from STS-1 through STS-107) were one-in-five. To address this unacceptable risk, the Orbiter Project Office (OPO) initiated a comprehensive investigation to understand and mitigate this risk. First, the team considered and eventually deemed unfeasible procuring and replacing all existing flight COPVs. OPO replaced the two vessels with the highest risk with existing flight spare units. Second, OPO instituted operational improvements in ground procedures to signficiantly reduce risk, without adversely affecting Shuttle capability. Third, OPO developed a comprehensive model to quantify the likelihood of occurrance. A fully-instrumented burst test (recording a lower burst pressure than expected) on a flight-certified vessel provided critical understanding of the behavior of Orbiter COPVs. A more accurate model was based on a newly-compiled comprehensive database of Kevlar data from LLNL and elsewhere. Considering hardware changes, operational improvements and reliability model refinements, the mean reliability was determined to be 0.998 for the remainder of the Shuttle Program (from 2007, for STS- 118 thru STS-135). Since limited hardware resources precluded full model validation through multiple tests, additional model confidence was sought through the first-ever Accelerated Stress Rupture Test (ASRT) of a flown flight article. A Bayesian statistical approach was developed to interpret possible test results. Since the lifetime observed in the ASRT exceeded initial estimates by one to two orders of magnitude, the Space Shuttle Program deemed there was significant conservatism in the model and accepted continued operation with existing flight hardware. Given the variability in tank-to-tank original prooftest response, a non-destructive evaluation (NDE) technique utilizing Raman Spectroscopy was developed to directly measure COPV residual stress state. Preliminary results showed that patterns of low fiber elastic strains over the outside vessel surface, together with measured permanent volume growth during proof, could be directly correlated to increased fiber stress ratios on the inside fibers adjacent to the liner, and thus reduced reliability.
Fortin, Carole; Feldman, Debbie Ehrmann; Cheriet, Farida; Gravel, Denis; Gauthier, Frédérique; Labelle, Hubert
2012-03-01
To determine overall, test-retest and inter-rater reliability of posture indices among persons with idiopathic scoliosis. A reliability study using two raters and two test sessions. Tertiary care paediatric centre. Seventy participants aged between 10 and 20 years with different types of idiopathic scoliosis (Cobb angle 15 to 60°) were recruited from the scoliosis clinic. Based on the XY co-ordinates of natural reference points (e.g., eyes) as well as markers placed on several anatomical landmarks, 32 angular and linear posture indices taken from digital photographs in the standing position were calculated from a specially developed software program. Generalisability theory served to estimate the reliability and standard error of measurement (SEM) for the overall, test-retest and inter-rater designs. Bland and Altman's method was also used to document agreement between sessions and raters. In the random design, dependability coefficients demonstrated a moderate level of reliability for six posture indices (ϕ=0.51 to 0.72) and a good level of reliability for 26 posture indices out of 32 (ϕ≥0.79). Error attributable to marker placement was negligible for most indices. Limits of agreement and SEM values were larger for shoulder protraction, trunk list, Q angle, cervical lordosis and scoliosis angles. The most reproducible indices were waist angles and knee valgus and varus. Posture can be assessed in a global fashion from photographs in persons with idiopathic scoliosis. Despite the good reliability of marker placement, other studies are needed to minimise measurement errors in order to provide a suitable tool for monitoring change in posture over time. Copyright © 2011 Chartered Society of Physiotherapy. Published by Elsevier Ltd. All rights reserved.
NASA Technical Reports Server (NTRS)
Bowe, Glenroy A.; Wang, Qianghua; Woodyard, James R.; Johnston, Richard R.; Brown, William J.
2005-01-01
The use of current balloon, control and communication technologies to test multi-junction solar sell in the stratosphere to achieve near AMO conditions have been investigated. The design criteria for the technologies are that they be reliable, low cost and readily available. Progress is reported on a program to design, launch, fly and retrieve payloads dedicated to testing multi-junction solar cells.
NASA Technical Reports Server (NTRS)
1983-01-01
The engineering and fabrication of the test ACT system, produced in the third program element of the IAAC Project is documented. The system incorporates pitch-augmented stability and wing-load alleviation, plus full authority fly-by-wire control of the elevators. The pitch-augmented stability is designed to have reliability sufficient to allow flight with neutral or negative inherent longitudinal stability.
Energy Efficient Engine integrated core/low spool design and performance report
NASA Technical Reports Server (NTRS)
Stearns, E. Marshall
1985-01-01
The Energy Efficient Engine (E3) is a NASA program to create fuel saving technology for future transport aircraft engines. The E3 technology advancements were demonstrated to operate reliably and achieve goal performance in tests of the Integrated Core/Low Spool vehicle. The first build of this undeveloped technology research engine set a record for low fuel consumption. Its design and detailed test results are herein presented.
Earth Scanner Bearing Accelerated Life Test
NASA Technical Reports Server (NTRS)
Dietz, Brian J.; VanDyk, Steven G.; Predmore, Roamer E.
2000-01-01
The Moderate Resolution Imaging Spectrometer (MODIS) optical instrument for NASA Goddard will measure biological and physical processes on the Earth's surface and in the lower atmosphere. A key component of the instrument is an extremely accurate scan mirror motor/encoder assembly. Of prime concern in the performance and reliability of the scan motor/encoder is bearing selection and lubrication. This paper describes life testing of the bearings and lubrication selected for the program.
Hallgren, Kevin A.; Greenfield, Brenna L.; Ladd, Benjamin O.
2016-01-01
Background Behavioral economic theories of drinking posit that the reinforcing value of engaging in activities with versus without alcohol influences drinking behavior. Measures of the reinforcement value of drugs and alcohol have been used in previous research, but little work has examined the psychometric properties of these measures. Objectives The present study aims to evaluate the factor structure, test-retest reliability, and concurrent validity of an alcohol-only version of the Adolescent Reinforcement Survey Schedule (ARSS-AUV). Methods A sample of 157 college student drinkers completed the ARSS-AUV at two time points 2–3 days apart. Test-retest reliability, hierarchical factor analysis, and correlations with other drinking measures were examined. Results Single, unidimensional general factors accounted for a majority of the variance in alcohol and alcohol-free reinforcement items. Residual factors emerged that typically represented alcohol or alcohol-free reinforcement while doing activities with friends, romantic or sexual partners, and family members. Individual ARSS-AUV items had fair-to-good test-retest reliability, while general and residual factors had excellent test-retest reliability. General alcohol reinforcement and alcohol reinforcement from friends and romantic partners were positively correlated with past-year alcohol consumption, heaviest drinking episode, and alcohol-related negative consequences. Alcohol-free reinforcement indices were unrelated to alcohol use or consequences. Conclusions/Importance The ARSS-AUV appears to demonstrate good reliability and mixed concurrent validity among college student drinkers. The instrument may provide useful information about alcohol reinforcement from various activities and people and could provide clinically-relevant information for prevention and treatment programs. PMID:27096713
Hallgren, Kevin A; Greenfield, Brenna L; Ladd, Benjamin O
2016-06-06
Behavioral economic theories of drinking posit that the reinforcing value of engaging in activities with versus without alcohol influences drinking behavior. Measures of the reinforcement value of drugs and alcohol have been used in previous research, but little work has examined the psychometric properties of these measures. The present study aims to evaluate the factor structure, test-retest reliability, and concurrent validity of an alcohol-only version of the Adolescent Reinforcement Survey Schedule (ARSS-AUV). A sample of 157 college student drinkers completed the ARSS-AUV at two time points 2-3 days apart. Test-retest reliability, hierarchical factor analysis, and correlations with other drinking measures were examined. Single, unidimensional general factors accounted for a majority of the variance in alcohol and alcohol-free reinforcement items. Residual factors emerged that typically represented alcohol or alcohol-free reinforcement while doing activities with friends, romantic or sexual partners, and family members. Individual ARSS-AUV items had fair-to-good test-retest reliability, while general and residual factors had excellent test-retest reliability. General alcohol reinforcement and alcohol reinforcement from friends and romantic partners were positively correlated with past-year alcohol consumption, heaviest drinking episode, and alcohol-related negative consequences. Alcohol-free reinforcement indices were unrelated to alcohol use or consequences. The ARSS-AUV appears to demonstrate good reliability and mixed concurrent validity among college student drinkers. The instrument may provide useful information about alcohol reinforcement from various activities and people and could provide clinically-relevant information for prevention and treatment programs.
[New questionnaire to assess self-efficacy toward physical activity in children].
Aedo, Angeles; Avila, Héctor
2009-10-01
To design a questionnaire for assessment of self-efficacy toward physical activity in school children, as well as to measure its construct validity, test-retest reliability, and internal consistency. A four-stage multimethod approach was used: (1) bibliographic research followed by exploratory study and the formulation of questions and responses based on a dichotomous scale of 14 items; (2) validation of the content by a panel of experts; (3) application of the preliminary version of the questionnaire to a sample of 900 school-aged children in Mexico City; and (4) determination of the construct validity, test-retest reliability, and internal consistency (Cronbach's alpha). Three factors were identified that explain 64.15% of the variance: the search for positive alternatives to physical activity, ability to deal with possible barriers to exercising, and expectations of skill or competence. The model was validated using the goodness of fit, and the result of 65% less than 0.05 indicated that the estimated factor model fit the data. Cronbach's consistency alpha was 0.733; test-retest reliability was 0.867. The scale designed has adequate reliability and validity. These results are a good indicator of self-efficacy toward physical activity in school children, which is important when developing programs intended to promote such behavior in this age group.
10 CFR 712.38 - Maintenance of medical records.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 4 2010-01-01 2010-01-01 false Maintenance of medical records. 712.38 Section 712.38 Energy DEPARTMENT OF ENERGY HUMAN RELIABILITY PROGRAM Medical Standards § 712.38 Maintenance of medical... medical record. The psychological record must: (1) Contain any clinical reports, test protocols and data...
Program of Research, Development, Test and Evaluation, FY 1978
1977-01-18
reliability of warning and the characterization of an SLSM attack. The performance of optical surveillance satellites Is gen - erally limited by the...development, and acquisition of weapon systems. Vi 1-2 o Enhance Innovation because it Is the life blood of future ac ’ fances . Most of the steps necessary
Methodological Approaches to Online Scoring of Essays.
ERIC Educational Resources Information Center
Chung, Gregory K. W. K.; O'Neil, Harold F., Jr.
This report examines the feasibility of scoring essays using computer-based techniques. Essays have been incorporated into many of the standardized testing programs. Issues of validity and reliability must be addressed to deploy automated approaches to scoring fully. Two approaches that have been used to classify documents, surface- and word-based…
2012-01-01
Background There is a great deal of variation in the existing capacity of primary prevention programs and policies addressing chronic disease to deliver evidence-based interventions (EBIs). In order to develop and evaluate implementation strategies that are tailored to the appropriate level of capacity, there is a need for an easy-to-administer tool to stage organizational readiness for EBIs. Methods Based on theoretical frameworks, including Rogers’ Diffusion of Innovations, we developed a survey instrument to measure four domains representing stages of readiness for EBI: awareness, adoption, implementation, and maintenance. A separate scale representing organizational climate as a potential mediator of readiness for EBIs was also included in the survey. Twenty-three questions comprised the four domains, with four to nine items each, using a seven-point response scale. Representatives from obesity, asthma, diabetes, and tobacco prevention programs serving diverse populations in the United States were surveyed (N = 243); test-retest reliability was assessed with 92 respondents. Results Confirmatory factor analysis (CFA) was used to test and refine readiness scales. Test-retest reliability of the readiness scales, as measured by intraclass correlation, ranged from 0.47–0.71. CFA found good fit for the five-item adoption and implementation scales and resulted in revisions of the awareness and maintenance scales. The awareness scale was split into two two-item scales, representing community and agency awareness. The maintenance scale was split into five- and four-item scales, representing infrastructural maintenance and evaluation maintenance, respectively. Internal reliability of scales (Cronbach’s α) ranged from 0.66–0.78. The model for the final revised scales approached good fit, with most factor loadings >0.6 and all >0.4. Conclusions The lack of adequate measurement tools hinders progress in dissemination and implementation research. These preliminary results help fill this gap by describing the reliability and measurement properties of a theory-based tool; the short, user-friendly instrument may be useful to researchers and practitioners seeking to assess organizational readiness for EBIs across a variety of chronic disease prevention programs and settings. PMID:22800294
Stamatakis, Katherine A; McQueen, Amy; Filler, Carl; Boland, Elizabeth; Dreisinger, Mariah; Brownson, Ross C; Luke, Douglas A
2012-07-16
There is a great deal of variation in the existing capacity of primary prevention programs and policies addressing chronic disease to deliver evidence-based interventions (EBIs). In order to develop and evaluate implementation strategies that are tailored to the appropriate level of capacity, there is a need for an easy-to-administer tool to stage organizational readiness for EBIs. Based on theoretical frameworks, including Rogers' Diffusion of Innovations, we developed a survey instrument to measure four domains representing stages of readiness for EBI: awareness, adoption, implementation, and maintenance. A separate scale representing organizational climate as a potential mediator of readiness for EBIs was also included in the survey. Twenty-three questions comprised the four domains, with four to nine items each, using a seven-point response scale. Representatives from obesity, asthma, diabetes, and tobacco prevention programs serving diverse populations in the United States were surveyed (N=243); test-retest reliability was assessed with 92 respondents. Confirmatory factor analysis (CFA) was used to test and refine readiness scales. Test-retest reliability of the readiness scales, as measured by intraclass correlation, ranged from 0.47-0.71. CFA found good fit for the five-item adoption and implementation scales and resulted in revisions of the awareness and maintenance scales. The awareness scale was split into two two-item scales, representing community and agency awareness. The maintenance scale was split into five- and four-item scales, representing infrastructural maintenance and evaluation maintenance, respectively. Internal reliability of scales (Cronbach's α) ranged from 0.66-0.78. The model for the final revised scales approached good fit, with most factor loadings >0.6 and all >0.4. The lack of adequate measurement tools hinders progress in dissemination and implementation research. These preliminary results help fill this gap by describing the reliability and measurement properties of a theory-based tool; the short, user-friendly instrument may be useful to researchers and practitioners seeking to assess organizational readiness for EBIs across a variety of chronic disease prevention programs and settings.
Reliability of risk assessment measures used in sexually violent predator proceedings.
Miller, Cailey S; Kimonis, Eva R; Otto, Randy K; Kline, Suzonne M; Wasserman, Adam L
2012-12-01
The field interrater reliability of three assessment tools frequently used by mental health professionals when evaluating sex offenders' risk for reoffending--the Psychopathy Checklist-Revised (PCL-R), the Minnesota Sex Offender Screening Tool-Revised (MnSOST-R) and the Static-99-was examined within the context of sexually violent predator program proceedings. Rater agreement was highest for the Static--99 (intraclass correlation coefficient [ICC₁] = .78) and lowest for the PCL-R (ICC₁ = .60; MnSOST-R ICC₁ = .74), although all instruments demonstrated lower field reliability than that reported in their test manuals. Findings raise concerns about the reliability of risk assessment tools that are used to inform judgments of risk in high-stake sexually violent predator proceedings. Implications for future research and suggestions for improving evaluator training to increase accuracy when informing legal decision making are discussed.
The Pieper-Zulkowski pressure ulcer knowledge test.
Pieper, Barbara; Zulkowski, Karen
2014-09-01
To describe the development and initial testing of the Pieper-Zulkowski Pressure Ulcer Knowledge Test (PZ-PUKT). Cross-sectional, instrument testing. Hospital association pressure ulcer educational program conference. Pressure ulcer research and guidelines from the last 5 years were examined for test item content. The initial PZ-PUKT had 115 items; response options were "true," "false," and "don't know." Registered nurses (N = 108) were randomly divided into 2 groups to take either the 60 prevention/risk and staging items or the 55 wound description items. Analyses of these responses resulted in 72 items, which were administered in total to a second cohort of 98 nurses for reliability. Cronbach's α was .80 for the 72-item PZ-PUKT. Cronbach's α values for the subscales were as follows: staging, .67; wound description, .64; and prevention/risk, .56. The mean correct scores were as follows: total, 80%; prevention, 77%; staging, 86%; and wound description, 77%. Nurses with wound care certification scored significantly higher on the PZ-PUKT than did nurses with other clinical certifications or with nurses who lacked certification. The PZ-PUKT has updated content about pressure ulcer prevention/risk, staging, and wound description. Reliability values are highest for the total test. Further use of the instrument in diverse settings will add to reliability testing and may provide direction for determination of a passing cutoff score.
Derakhshandeh, Zahra; Amini, Mitra; Kojuri, Javad; Dehbozorgian, Marziyeh
2018-01-01
Clinical reasoning is one of the most important skills in the process of training a medical student to become an efficient physician. Assessment of the reasoning skills in a medical school program is important to direct students' learning. One of the tests for measuring the clinical reasoning ability is Clinical Reasoning Problems (CRPs). The major aim of this study is to measure psychometric qualities of CRPs and define correlation between this test and routine MCQ in cardiology department of Shiraz medical school. This study was a descriptive study conducted on total cardiology residents of Shiraz Medical School. The study population consists of 40 residents in 2014. The routine CRPs and the MCQ tests was designed based on similar objectives and were carried out simultaneously. Reliability, item difficulty, item discrimination, and correlation between each item and the total score of CRPs were all measured by Excel and SPSS software for checking psycometeric CRPs test. Furthermore, we calculated the correlation between CRPs test and MCQ test. The mean differences of CRPs test score between residents' academic year [second, third and fourth year] were also evaluated by Analysis of variances test (One Way ANOVA) using SPSS software (version 20)(α=0.05). The mean and standard deviation of score in CRPs was 10.19 ±3.39 out of 20; in MCQ, it was 13.15±3.81 out of 20. Item difficulty was in the range of 0.27-0.72; item discrimination was 0.30-0.75 with question No.3 being the exception (that was 0.24). The correlation between each item and the total score of CRP was 0.26-0.87; the correlation between CRPs test and MCQ test was 0.68 (p<0.001). The reliability of the CRPs was 0.72 as calculated by using Cronbach's alpha. The mean score of CRPs was different among residents based on their academic year and this difference was statistically significant (p<0.001). The results of this present investigation revealed that CRPs could be reliable test for measuring clinical reasoning in residents. It can be included in cardiology residency assessment programs.
Methodology to identify risk-significant components for inservice inspection and testing
DOE Office of Scientific and Technical Information (OSTI.GOV)
Anderson, M.T.; Hartley, R.S.; Jones, J.L. Jr.
1992-08-01
Periodic inspection and testing of vital system components should be performed to ensure the safe and reliable operation of Department of Energy (DOE) nuclear processing facilities. Probabilistic techniques may be used to help identify and rank components by their relative risk. A risk-based ranking would allow varied DOE sites to implement inspection and testing programs in an effective and cost-efficient manner. This report describes a methodology that can be used to rank components, while addressing multiple risk issues.
Verification Tools Secure Online Shopping, Banking
NASA Technical Reports Server (NTRS)
2010-01-01
Just like rover or rocket technology sent into space, the software that controls these technologies must be extensively tested to ensure reliability and effectiveness. Ames Research Center invented the open-source Java Pathfinder (JPF) toolset for the deep testing of Java-based programs. Fujitsu Labs of America Inc., based in Sunnyvale, California, improved the capabilities of the JPF Symbolic Pathfinder tool, establishing the tool as a means of thoroughly testing the functionality and security of Web-based Java applications such as those used for Internet shopping and banking.
A Rapid Assessment Tool for affirming good practice in midwifery education programming.
Fullerton, Judith T; Johnson, Peter; Lobe, Erika; Myint, Khine Haymar; Aung, Nan Nan; Moe, Thida; Linn, Nay Aung
2016-03-01
to design a criterion-referenced assessment tool that could be used globally in a rapid assessment of good practices and bottlenecks in midwifery education programs. a standard tool development process was followed, to generate standards and reference criteria; followed by external review and field testing to document psychometric properties. review of standards and scoring criteria were conducted by stakeholders around the globe. Field testing of the tool was conducted in Myanmar. eleven of Myanmar׳s 22 midwifery education programs participated in the assessment. the clinimetric tool was demonstrated to have content validity and high inter-rater reliability in use. a globally validated tool, and accompanying user guide and handbook are now available for conducting rapid assessments of compliance with good practice criteria in midwifery education programming. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.
Magellan attitude and articulation control subsystem closed loop testing
NASA Technical Reports Server (NTRS)
Olschansky, David G.
1987-01-01
In the spring of 1989, the Magellan spacecraft will embark on a two-year mission to map the surface of the planet Venus. Guiding it there will be the Attitude and Articulation Control Subsystem (AACS). To ensure reliable operations the AACS is being put through a rigorous test program at Martin Marietta Denver Aerospace. Before Magellan ever leaves the Space Shuttle bay from which it is to be launched, its components will have flown a simulated spaceflight in a ground-based lab. The primary objectives of the test program are to verify form, fit, and function of the AACS, particularly subsystem external interfaces and functional operation of the flight software. This paper discusses the Magellan Closed Loop Test Systems which makes realistic tests possible by simulating the dynamic and 'visual' flight environment for AACS components in the lab.
10 CFR 712.19 - Removal from HRP.
Code of Federal Regulations, 2010 CFR
2010-01-01
... OF ENERGY HUMAN RELIABILITY PROGRAM Establishment of and Procedures for the Human Reliability Program... immediately remove that individual from HRP duties pending a determination of the individual's reliability. A... HRP duties pending a determination of the individual's reliability is an interim, precautionary action...
NASA Technical Reports Server (NTRS)
Roskam, J.; Muirhead, V. U.; Smith, H. W.; Henderson, T. D.
1977-01-01
The design, construction, and costs of a test facility for determining the sound transmission loss characteristics of various panels and panel treatments are described. The pressurization system and electronic equipment used in experimental testing are discussed as well as the reliability of the facility and the data gathered. Tests results are compared to pertinent acoustical theories for panel behavior and minor anomalies in the data are examined. A method for predicting panel behavior in the stiffness region is also presented.
Galileo attitude and articulation control subsystem closed loop testing
NASA Technical Reports Server (NTRS)
Lembeck, M. F.; Pignatano, N. D.
1983-01-01
In order to ensure the reliable operation of the Attitude and Articulation Control Subsystem (AACS) which will guide the Galileo spacecraft on its two and one-half year journey to Jupiter, the AACS is being rigorously tested. The primary objectives of the test program are the verification of the AACS's form, fit, and function, especially with regard to subsystem external interfaces and the functional operation of the flight software. Attention is presently given to the Galileo Closed Loop Test System, which simulates the dynamic and 'visual' flight environment for AACS components in the laboratory.
Software reliability: Application of a reliability model to requirements error analysis
NASA Technical Reports Server (NTRS)
Logan, J.
1980-01-01
The application of a software reliability model having a well defined correspondence of computer program properties to requirements error analysis is described. Requirements error categories which can be related to program structural elements are identified and their effect on program execution considered. The model is applied to a hypothetical B-5 requirement specification for a program module.
Framework for a National Testing and Evaluation Program ...
Abstract:The National STEPP Program seeks to improve water quality by accelerating the effective implementation and adoption of innovative stormwater management technologies. Itwill attempt to accomplish this by establishing practices through highly reliable, and cost-effective Stormwater control measures (SCM) testing, evaluation, and verification services. The program will aim to remove barriers to innovation, minimize duplicative performance evaluation needs, increase confidence that regulatory requirements are met by creating consistency among testing and evaluation protocols, and establishing equity between public domain and proprietary SCM evaluation approaches.The Environmental Technology Verification Program, established by the U.S. Environmental Protection Agency (EPA) 18 years ago, was the only national program of its kindin the stormwater sector, but is now defunct, leaving a national leadership void. The STEPP initiative was triggered in part by regulatory demands in the government and private sectors to fill this vacuum. A concerted focus and study of this matter led to the release of a Water Environment Federation (WEF) white paper entitled “Investigation into the Feasibility of a National Testing and Evaluation Program for Stormwater Products and Practices” in February 2014. During this second phase of the STEPP initiative, and with EPA support, five analogous technology evaluation programs related to both stormwater and non-stormwater were an
Reliability and Validity of the Work and Well-Being Inventory (WBI) for Employees.
Vendrig, A A; Schaafsma, F G
2018-06-01
Purpose The purpose of this study is to measure the psychometric properties of the Work and Wellbeing Inventory (WBI) (in Dutch: VAR-2), a screening tool that is used within occupational health care and rehabilitation. Our research question focused on the reliability and validity of this inventory. Methods Over the years seven different samples of workers, patients and sick listed workers varying in size between 89 and 912 participants (total: 2514), were used to measure the test-retest reliability, the internal consistency, the construct and concurrent validity, and the criterion and predictive validity. Results The 13 scales displayed good internal consistency and test-retest reliability. The constructive validity of the WBI could clearly be demonstrated in both patients and healthy workers. Confirmative factor analyses revealed a CFI >.90 for all scales. The depression scale predicted future work absenteeism (>6 weeks) because of a common mental disorder in healthy workers. The job strain scale and the illness behavior scale predicted long term absenteeism (>3 months) in workers with short-term absenteeism. The illness behavior scale moderately predicted return to work in rehab patients attending an intensive multidisciplinary program. Conclusions The WBI is a valid and reliable tool for occupational health practitioners to screen for risk factors for prolonged or future sickness absence. With this tool they will have reliable indications for further advice and interventions to restore the work ability.
The NASA-Lewis/ERDA solar heating and cooling technology program. [project planning/energy policy
NASA Technical Reports Server (NTRS)
Couch, J. P.; Bloomfield, H. S.
1975-01-01
Plans by NASA to carry out a major role in a solar heating and cooling program are presented. This role would be to create and test the enabling technology for future solar heating, cooling, and combined heating/cooling systems. The major objectives of the project are to achieve reduction in solar energy system costs, while maintaining adequate performance, reliability, life, and maintenance characteristics. The project approach is discussed, and will be accomplished principally by contract with industry to develop advanced components and subsystems. Advanced hardware will be tested to establish 'technology readiness' both under controlled laboratory conditions and under real sun conditions.
Advanced Space Transportation Program (ASTP)
2003-07-01
NASA's X-37 Approach and Landing Test Vehicle is installed is a structural facility at Boeing's Huntington Beach, California plant. Tests, completed in July, were conducted to verify the structural integrity of the vehicle in preparation for atmospheric flight tests. Atmospheric flight tests of the Approach and Landing Test Vehicle are scheduled for 2004 and flight tests of the Orbital Vehicle are scheduled for 2006. The X-37 experimental launch vehicle is roughly 27.5 feet (8.3 meters) long and 15 feet (4.5 meters) in wingspan. It's experiment bay is 7 feet (2.1 meters) long and 4 feet (1.2 meters) in diameter. Designed to operate in both the orbital and reentry phases of flight, the X-37 will increase both safety and reliability, while reducing launch costs from $10,000 per pound to $1,000.00 per pound. The X-37 program is managed by the Marshall Space Flight Center and built by the Boeing Company.
DOE Office of Scientific and Technical Information (OSTI.GOV)
De La Fosse, P.H.; Black, A.D.; DiBona, B.G.
1983-01-01
A major limitation of downhole mud motors for geothermal drilling, as well as straight-hole oil and gas drilling, is the bearing section. Reduced bearing life results from the inability to seal a lubricant in the bearing pack. A reliable rotary seal will extend the bearing life and will allow high pressure drops across the bit for improved bottomhole cleaning and increased drilling rate. This paper summarizes the results of a six-year program funded by the U.S. Department of Energy/Division of Geothermal Energy to develop a sealed bearing pack for use with downhole motors in geothermal applications. Descriptions of the Sealmore » Test Machine, Lubricant Test Machine and Bearing Pack Test Facility are presented. Summaries of all seal tests, lubricant tests and bearing pack tests are provided; and a comprehensive program bibliography is presented.« less
Reliability analysis of laminated CMC components through shell subelement techniques
NASA Technical Reports Server (NTRS)
Starlinger, A.; Duffy, S. F.; Gyekenyesi, J. P.
1992-01-01
An updated version of the integrated design program C/CARES (composite ceramic analysis and reliability evaluation of structures) was developed for the reliability evaluation of CMC laminated shell components. The algorithm is now split in two modules: a finite-element data interface program and a reliability evaluation algorithm. More flexibility is achieved, allowing for easy implementation with various finite-element programs. The new interface program from the finite-element code MARC also includes the option of using hybrid laminates and allows for variations in temperature fields throughout the component.
Critical joints in large composite aircraft structure
NASA Technical Reports Server (NTRS)
Nelson, W. D.; Bunin, B. L.; Hart-Smith, L. J.
1983-01-01
A program was conducted at Douglas Aircraft Company to develop the technology for critical structural joints of composite wing structure that meets design requirements for a 1990 commercial transport aircraft. The prime objective of the program was to demonstrate the ability to reliably predict the strength of large bolted composite joints. Ancillary testing of 180 specimens generated data on strength and load-deflection characteristics which provided input to the joint analysis. Load-sharing between fasteners in multirow bolted joints was computed by the nonlinear analysis program A4EJ. This program was used to predict strengths of 20 additional large subcomponents representing strips from a wing root chordwise splice. In most cases, the predictions were accurate to within a few percent of the test results. In some cases, the observed mode of failure was different than anticipated. The highlight of the subcomponent testing was the consistent ability to achieve gross-section failure strains close to 0.005. That represents a considerable improvement over the state of the art.
Technology advancement of the static feed water electrolysis process
NASA Technical Reports Server (NTRS)
Schubert, F. H.; Wynveen, R. A.
1977-01-01
A program to advance the technology of oxygen- and hydrogen-generating subsystems based on water electrolysis was studied. Major emphasis was placed on static feed water electrolysis, a concept characterized by low power consumption and high intrinsic reliability. The static feed based oxygen generation subsystem consists basically of three subassemblies: (1) a combined water electrolysis and product gas dehumidifier module; (2) a product gas pressure controller and; (3) a cyclically filled water feed tank. Development activities were completed at the subsystem as well as at the component level. An extensive test program including single cell, subsystem and integrated system testing was completed with the required test support accessories designed, fabricated, and assembled. Mini-product assurance activities were included throughout all phases of program activities. An extensive number of supporting technology studies were conducted to advance the technology base of the static feed water electrolysis process and to resolve problems.
Test-Retest Reliability of Innovated Strength Tests for Hip Muscles
Meyer, Christophe; Corten, Kristoff; Wesseling, Mariska; Peers, Koen; Simon, Jean-Pierre; Jonkers, Ilse; Desloovere, Kaat
2013-01-01
The burden of hip muscles weakness and its relation to other impairments has been well documented. It is therefore a pre-requisite to have a reliable method for clinical assessment of hip muscles function allowing the design and implementation of a proper strengthening program. Motor-driven dynamometry has been widely accepted as the gold-standard for lower limb muscle strength assessment but is mainly related to the knee joint. Studies focusing on the hip joint are less exhaustive and somewhat discrepant with regard to optimal participants position, consequently influencing outcome measures. Thus, we aimed to develop a standardized test setup for the assessment of hip muscles strength, i.e. flexors/extensors and abductors/adductors, with improved participant stability and to define its psychometric characteristics. Eighteen participants performed unilateral isokinetic and isometric contractions of the hip muscles in the sagittal and coronal plane at two separate occasions. Peak torque and normalized peak torque were measured for each contraction. Relative and absolute measures of reliability were calculated using the intraclass correlation coefficient and standard error of measurement, respectively. Results from this study revealed higher levels of between-day reliability of isokinetic/isometric hip abduction/flexion peak torque compared to existing literature. The least reliable measures were found for hip extension and adduction, which could be explained by a less efficient stabilization technique. Our study additionally provided a first set of reference normalized data which can be used in future research. PMID:24260550
Validity of instruments to assess students' travel and pedestrian safety
2010-01-01
Background Safe Routes to School (SRTS) programs are designed to make walking and bicycling to school safe and accessible for children. Despite their growing popularity, few validated measures exist for assessing important outcomes such as type of student transport or pedestrian safety behaviors. This research validated the SRTS school travel survey and a pedestrian safety behavior checklist. Methods Fourth grade students completed a brief written survey on how they got to school that day with set responses. Test-retest reliability was obtained 3-4 hours apart. Convergent validity of the SRTS travel survey was assessed by comparison to parents' report. For the measure of pedestrian safety behavior, 10 research assistants observed 29 students at a school intersection for completion of 8 selected pedestrian safety behaviors. Reliability was determined in two ways: correlations between the research assistants' ratings to that of the Principal Investigator (PI) and intraclass correlations (ICC) across research assistant ratings. Results The SRTS travel survey had high test-retest reliability (κ = 0.97, n = 96, p < 0.001) and convergent validity (κ = 0.87, n = 81, p < 0.001). The pedestrian safety behavior checklist had moderate reliability across research assistants' ratings (ICC = 0.48) and moderate correlation with the PI (r = 0.55, p =< 0.01). When two raters simultaneously used the instrument, the ICC increased to 0.65. Overall percent agreement (91%), sensitivity (85%) and specificity (83%) were acceptable. Conclusions These validated instruments can be used to assess SRTS programs. The pedestrian safety behavior checklist may benefit from further formative work. PMID:20482778
Test Planning Approach and Lessons
NASA Technical Reports Server (NTRS)
Parkinson, Douglas A.; Brown, Kendall K.
2004-01-01
As NASA began technology risk reduction activities and planning for the next generation launch vehicle under the Space Launch Initiative (SLI), now the Next Generation Launch Technology (NGLT) Program, a review of past large liquid rocket engine development programs was performed. The intent of the review was to identify any significant lessons from the development testing programs that could be applied to current and future engine development programs. Because the primary prototype engine in design at the time of this study was the Boeing-Rocketdyne RS-84, the study was slightly biased towards LOX/RP-1 liquid propellant engines. However, the significant lessons identified are universal. It is anticipated that these lessons will serve as a reference for test planning in the Engine Systems Group at Marshall Space Flight Center (MSFC). Towards the end of F-1 and J-2 engine development testing, NASA/MSFC asked Rocketdyne to review those test programs. The result was a document titled, Study to Accelerate Development by Test of a Rocket Engine (R-8099). The "intent (of this study) is to apply this thinking and learning to more efficiently develop rocket engines to high reliability with improved cost effectivenes" Additionally, several other engine programs were reviewed - such as SSME, NSTS, STME, MC-1, and RS-83- to support or refute the R-8099. R-8099 revealed two primary lessons for test planning, which were supported by the other engine development programs. First, engine development programs can benefit from arranging the test program for engine system testing as early as feasible. The best test for determining environments is at the system level, the closest to the operational flight environment. Secondly, the component testing, which tends to be elaborate, should instead be geared towards reducing risk to enable system test. Technical risk can be reduced at the component level, but the design can only be truly verified and validated after engine system testing.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wong, S.M.; Boccio, J.L.; Karimian, S.
1986-01-01
In this paper, a trial application of reliability technology to the emergency diesel generator system at the Trojan Nuclear Power Plant is presented. An approach for formulating a reliability program plan for this system is being developed. The trial application has shown that a reliability program process, using risk- and reliability-based techniques, can be interwoven into current plant operational activities to help in controlling, analyzing, and predicting faults that can challenge safety systems. With the cooperation of the utility, Portland General Electric Co., this reliability program can eventually be implemented at Trojan to track its effectiveness.
Design, fabrication, and operation of a test rig for high-speed tapered-roller bearings
NASA Technical Reports Server (NTRS)
Signer, H. R.
1974-01-01
A tapered-roller bearing test machine was designed, fabricated and successfully operated at speeds to 20,000 rpm. Infinitely variable radial loads to 26,690 N (6,000 lbs.) and thrust loads to 53,380 N (12,000 lbs.) can be applied to test bearings. The machine instrumentation proved to have the accuracy and reliability required for parametric bearing performance testing and has the capability of monitoring all programmed test parameters at continuous operation during life testing. This system automatically shuts down a test if any important test parameter deviates from the programmed conditions, or if a bearing failure occurs. A lubrication system was developed as an integral part of the machine, capable of lubricating test bearings by external jets and by means of passages feeding through the spindle and bearing rings into the critical internal bearing surfaces. In addition, provisions were made for controlled oil cooling of inner and outer rings to effect the type of bearing thermal management that is required when testing at high speeds.
Klein, Britt; Meyer, Denny; Austin, David William; Abbott, Jo-Anne M
2015-01-01
Background Internet-based assessment has the potential to assist with the diagnosis of mental health disorders and overcome the barriers associated with traditional services (eg, cost, stigma, distance). Further to existing online screening programs available, there is an opportunity to deliver more comprehensive and accurate diagnostic tools to supplement the assessment and treatment of mental health disorders. Objective The aim was to evaluate the diagnostic criterion validity and test-retest reliability of the electronic Psychological Assessment System (e-PASS), an online, self-report, multidisorder, clinical assessment and referral system. Methods Participants were 616 adults residing in Australia, recruited online, and representing prospective e-PASS users. Following e-PASS completion, 158 participants underwent a telephone-administered structured clinical interview and 39 participants repeated the e-PASS within 25 days of initial completion. Results With structured clinical interview results serving as the gold standard, diagnostic agreement with the e-PASS varied considerably from fair (eg, generalized anxiety disorder: κ=.37) to strong (eg, panic disorder: κ=.62). Although the e-PASS’ sensitivity also varied (0.43-0.86) the specificity was generally high (0.68-1.00). The e-PASS sensitivity generally improved when reducing the e-PASS threshold to a subclinical result. Test-retest reliability ranged from moderate (eg, specific phobia: κ=.54) to substantial (eg, bulimia nervosa: κ=.87). Conclusions The e-PASS produces reliable diagnostic results and performs generally well in excluding mental disorders, although at the expense of sensitivity. For screening purposes, the e-PASS subclinical result generally appears better than a clinical result as a diagnostic indicator. Further development and evaluation is needed to support the use of online diagnostic assessment programs for mental disorders. Trial Registration Australian and New Zealand Clinical Trials Registry ACTRN121611000704998; http://www.anzctr.org.au/trial_view.aspx?ID=336143 (Archived by WebCite at http://www.webcitation.org/618r3wvOG). PMID:26392066
Validation of a method for assessing resident physicians' quality improvement proposals.
Leenstra, James L; Beckman, Thomas J; Reed, Darcy A; Mundell, William C; Thomas, Kris G; Krajicek, Bryan J; Cha, Stephen S; Kolars, Joseph C; McDonald, Furman S
2007-09-01
Residency programs involve trainees in quality improvement (QI) projects to evaluate competency in systems-based practice and practice-based learning and improvement. Valid approaches to assess QI proposals are lacking. We developed an instrument for assessing resident QI proposals--the Quality Improvement Proposal Assessment Tool (QIPAT-7)-and determined its validity and reliability. QIPAT-7 content was initially obtained from a national panel of QI experts. Through an iterative process, the instrument was refined, pilot-tested, and revised. Seven raters used the instrument to assess 45 resident QI proposals. Principal factor analysis was used to explore the dimensionality of instrument scores. Cronbach's alpha and intraclass correlations were calculated to determine internal consistency and interrater reliability, respectively. QIPAT-7 items comprised a single factor (eigenvalue = 3.4) suggesting a single assessment dimension. Interrater reliability for each item (range 0.79 to 0.93) and internal consistency reliability among the items (Cronbach's alpha = 0.87) were high. This method for assessing resident physician QI proposals is supported by content and internal structure validity evidence. QIPAT-7 is a useful tool for assessing resident QI proposals. Future research should determine the reliability of QIPAT-7 scores in other residency and fellowship training programs. Correlations should also be made between assessment scores and criteria for QI proposal success such as implementation of QI proposals, resident scholarly productivity, and improved patient outcomes.
Brayton advanced heat receiver development program
NASA Technical Reports Server (NTRS)
Heidenreich, G. R.; Downing, R. S.; Lacey, Dovie E.
1989-01-01
NASA Lewis Research Center is managing an advanced solar dynamic (ASD) space power program. The objective of the ASD program is to develop small and lightweight solar dynamic systems which show significant improvement in efficiency and specific mass over the baseline design derived from the Space Station Freedom technology. The advanced heat receiver development program is a phased program to design, fabricate and test elements of a 7-kWe heat-receiver/thermal-energy-storage subsystem. Receivers for both Brayton and Stirling heat engines are being developed under separate contracts. Phase I, described here, is the current eighteen month effort to design and perform critical technology experiments on innovative concepts designed to reduce mass without compromising thermal efficiency and reliability.
CSTI Earth-to-orbit propulsion research and technology program overview
NASA Technical Reports Server (NTRS)
Gentz, Steven J.
1993-01-01
NASA supports a vigorous Earth-to-orbit (ETO) research and technology program as part of its Civil Space Technology Initiative. The purpose of this program is to provide an up-to-date technology base to support future space transportation needs for a new generation of lower cost, operationally efficient, long-lived and highly reliable ETO propulsion systems by enhancing the knowledge, understanding and design methodology applicable to advanced oxygen/hydrogen and oxygen/hydrocarbon ETO propulsion systems. Program areas of interest include analytical models, advanced component technology, instrumentation, and validation/verification testing. Organizationally, the program is divided between technology acquisition and technology verification as follows: (1) technology acquisition; and (2) technology verification.
[Validation of Diabetes Mellitus Knowledge (DKN-A) and Attitude (ATT-19) Questionnaires].
Torres, Heloisa C; Virginia A, Hortale; Schall, Virginia T
2005-12-01
To present the cross-cultural adaptation of the Diabetes Knowledge Scale and Attitudes Questionnaires targeted to evaluate Brazilian Diabetes Mellitus patients. These questionnaires underwent the following steps: presentation, translation, back translation, semantic and idiomatic assessments, cultural and conceptual similarities and a pilot test. They were administered in two opportunities a month apart in a sample of 61 Diabetes Mellitus type-2 patients from a university hospital. The study design included a test-retest reliability of the answers, which were analyzed and estimated by means of the Kappa coefficient. The findings suggested an adequacy of the instruments to the Portuguese language and Brazilian cultural identity. The Kappa coefficient in the reliability analysis showed levels of concordance from moderate to high (0.44 to 0.69) for most questions. The questionnaires proved to be of very easy understanding for the studied subjects and reliable and valid for use in the evaluation of diabetes educational programs in the reality of Brazil.
1984-03-01
Engineering initiative to develop an orderly plan and procedure to assure that USAF acquire reliable, high quality, supportable avionics with a higher avail...susceptibility te~t~ (radiated and conducted), and emission of radio frequency energy tests."l6) Other electrical stresses can include over/under voltage...jo ints, poor welds, and dielectric defects. Also, instruments with components unable to endu very high temperatures can be safely tested. 1-19
Small Explorer Data System MIL-STD-1773 fiber optic bus
NASA Technical Reports Server (NTRS)
Flanegan, Mark; Label, Ken
1992-01-01
The MIL-STD-1773 Fiber Optic Data Bus as implemented in the GSFC Small Explorer Data System (SEDS) for the Small Explorer Program is described. It provides an overview of the SEDS MIL-STD-1773 bus components system design considerations, reliability figures, acceptance and qualification testing requirements, radiation requirements and tests, error handling considerations, and component heritage. The first mission using the bus will be launched in June of 1992.
Training Guide for Observation and Interviewing in Marine Corps Task Analysis. Training Manual 3
1975-08-01
McGraw- Hill Book Co., 1954. This is a comprehensive text that treats theory and sta- tistical operations in psychological testing . Chapter 14 deals...with reliability and validity of measures. -44- Reliabilitv and Validity (cont’d.) Cronbach, L., ESSENTIALS OF PSYCHOLOGICAL TESTING , 2nd ed., New...Commandant of the Marine Corps (Code RD) And Monitored By Personnel and Training Research Programs Psychological Sciences Division Office of Naval
CCARES: A computer algorithm for the reliability analysis of laminated CMC components
NASA Technical Reports Server (NTRS)
Duffy, Stephen F.; Gyekenyesi, John P.
1993-01-01
Structural components produced from laminated CMC (ceramic matrix composite) materials are being considered for a broad range of aerospace applications that include various structural components for the national aerospace plane, the space shuttle main engine, and advanced gas turbines. Specifically, these applications include segmented engine liners, small missile engine turbine rotors, and exhaust nozzles. Use of these materials allows for improvements in fuel efficiency due to increased engine temperatures and pressures, which in turn generate more power and thrust. Furthermore, this class of materials offers significant potential for raising the thrust-to-weight ratio of gas turbine engines by tailoring directions of high specific reliability. The emerging composite systems, particularly those with silicon nitride or silicon carbide matrix, can compete with metals in many demanding applications. Laminated CMC prototypes have already demonstrated functional capabilities at temperatures approaching 1400 C, which is well beyond the operational limits of most metallic materials. Laminated CMC material systems have several mechanical characteristics which must be carefully considered in the design process. Test bed software programs are needed that incorporate stochastic design concepts that are user friendly, computationally efficient, and have flexible architectures that readily incorporate changes in design philosophy. The CCARES (Composite Ceramics Analysis and Reliability Evaluation of Structures) program is representative of an effort to fill this need. CCARES is a public domain computer algorithm, coupled to a general purpose finite element program, which predicts the fast fracture reliability of a structural component under multiaxial loading conditions.
Digital Divide Measurement in Lembata Regency Using SIBIS
NASA Astrophysics Data System (ADS)
Gabriel, Cecilia Dai Payon Binti; Setyohadi, Djoko Budiyanto; Suyoto
2018-02-01
Along with technological development in Indonesia, digital divide occurs in various regions, which were behind in terms of information on how to use, access and utilize ICT in collecting information from internet. One of the regions is Lembata Regency in East Nusa Tenggara, where digital divide among the people should be measured. The purpose of this study was to determine the level of digital divide among the people of Lembata Regency. To determine the level of digital divide, we used SIBIS GPS (General Population Survey) method, which consisted of several indicators or aspect, i.e. internet usage behavior, internet utilization, and e-government. We also performed two tests, i.e. validity test and reliability test to obtain value of index of digital divide measurement among the people of Lembata Regency. The results of validity test which is processed using SPSS program are categorized valid for each variable indicator and the reliability test results show reliable status. According to the test results on digital discrepancy in Lembata people, the internet usage attitude indicator is categorized low which is 63.1%, the internet usage function indicator is categorized low which is 64%, and the digital discrepancy of e-government indicator is categorized medium which is 40.4%. Therefore, the result of this study because consideration for the government of Lembata Regency in improving ICT services in e-government and in distributing ICT access and ability equally to the people.
Bell Helicopter Advanced Rotocraft Transmission (ART) program
NASA Technical Reports Server (NTRS)
Henry, Zachary S.
1995-01-01
Future rotorcraft transmissions require key emerging material and component technologies using advanced and innovative design practices in order to meet the requirements for a reduced weight to power ratio, a decreased noise level, and a substantially increased reliability. The specific goals for the future rotorcraft transmission when compared with a current state-of-the-art transmission (SOAT) are: (1) a 25 percent weight reduction; (2) a 10 dB reduction in the transmitted noise level; and (3) a system reliability of 5000 hours mean-time-between-removal (MTBR) for the transmission. This report summarizes the work conducted by Bell Helicopter Textron, Inc. to achieve these goals under the Advanced Rotorcraft Transmission (ART) program from 1988 to 1995. The reference aircraft selected by BHTI for the ART program was the Tactical Tiltrotor which is a 17,000 lb gross weight aircraft. A tradeoff study was conducted comparing the ART with a Selected SOAT. The results showed the ART to be 29 percent lighter and up to 13 dB quieter with a calculated MTBR in excess of 5000 hours. The results of the following high risk component and material tests are also presented: (1) sequential meshing high contact ratio planetary with cantilevered support posts; (2) thin dense chrome plated M50 NiL double row spherical roller planetary bearings; (3) reduced kinematic error and increased bending strength spiral bevel gears; (4) high temperature WE43 magnesium housing evaluation and coupon corrosion tests; (5) flexure fatigue tests of precision forged coupons simulating precision forged gear teeth; and (6) flexure fatigue tests of plasma carburized coupons simulating plasma carburized gear teeth.
Banta, E.R.; Hill, M.C.; Poeter, E.; Doherty, J.E.; Babendreier, J.
2008-01-01
The open-source, public domain JUPITER (Joint Universal Parameter IdenTification and Evaluation of Reliability) API (Application Programming Interface) provides conventions and Fortran-90 modules to develop applications (computer programs) for analyzing process models. The input and output conventions allow application users to access various applications and the analysis methods they embody with a minimum of time and effort. Process models simulate, for example, physical, chemical, and (or) biological systems of interest using phenomenological, theoretical, or heuristic approaches. The types of model analyses supported by the JUPITER API include, but are not limited to, sensitivity analysis, data needs assessment, calibration, uncertainty analysis, model discrimination, and optimization. The advantages provided by the JUPITER API for users and programmers allow for rapid programming and testing of new ideas. Application-specific coding can be in languages other than the Fortran-90 of the API. This article briefly describes the capabilities and utility of the JUPITER API, lists existing applications, and uses UCODE_2005 as an example.
2007-09-09
Under the goals of the Vision for Space Exploration, Ares I is a chief component of the cost-effective space transportation infrastructure being developed by NASA's Constellation Program. This transportation system will safely and reliably carry human explorers back to the moon, and then onward to Mars and other destinations in the solar system. The Ares I effort includes multiple project element teams at NASA centers and contract organizations around the nation, and is managed by the Exploration Launch Projects Office at NASA's Marshall Space Flight Center (MFSC). ATK Launch Systems near Brigham City, Utah, is the prime contractor for the first stage booster. ATK's subcontractor, United Space Alliance of Houston, is designing, developing and testing the parachutes at its facilities at NASA's Kennedy Space Center in Florida. NASA's Johnson Space Center in Houston hosts the Constellation Program and Orion Crew Capsule Project Office and provides test instrumentation and support personnel. Together, these teams are developing vehicle hardware, evolving proven technologies, and testing components and systems. Their work builds on powerful, reliable space shuttle propulsion elements and nearly a half-century of NASA space flight experience and technological advances. Ares I is an inline, two-stage rocket configuration topped by the Crew Exploration Vehicle, its service module, and a launch abort system. The launch vehicle's first stage is a single, five-segment reusable solid rocket booster derived from the Space Shuttle Program's reusable solid rocket motor that burns a specially formulated and shaped solid propellant called polybutadiene acrylonitrile (PBAN). The second or upper stage will be propelled by a J-2X main engine fueled with liquid oxygen and liquid hydrogen. This HD video image depicts a test firing of a 40k subscale J2X injector at MSFC's test stand 115. (Highest resolution available)
Human Rating the Orion Parachute System
NASA Technical Reports Server (NTRS)
Machin, Ricardo A.; Fisher, Timothy E.; Evans, Carol T.; Stewart, Christine E.
2011-01-01
Human rating begins with design. Converging on the requirements and identifying the risks as early as possible in the design process is essential. Understanding of the interaction between the recovery system and the spacecraft will in large part dictate the achievable reliability of the final design. Component and complete system full-scale flight testing is critical to assure a realistic evaluation of the performance and reliability of the parachute system. However, because testing is so often difficult and expensive, comprehensive analysis of test results and correlation to accurate modeling completes the human rating process. The National Aeronautics and Space Administration (NASA) Orion program uses parachutes to stabilize and decelerate the Crew Exploration Vehicle (CEV) spacecraft during subsonic flight in order to deliver a safe water landing. This paper describes the approach that CEV Parachute Assembly System (CPAS) will take to human rate the parachute recovery system for the CEV.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-03-28
... Interim Staff Guidance on Standard Review Plan, Section 17.4, ``Reliability Assurance Program'' AGENCY... design reliability assurance program (RAP). This ISG updates the guidance provided to the staff in Standard Review Plan (SRP), Section 17.4, ``Reliability Assurance Program,'' of NUREG-0800, ``Standard...
Program for refan JT8D engine design, fabrication and test, phase 2
NASA Technical Reports Server (NTRS)
Glass, J. A.; Zimmerman, E. S.; Scaramella, V. M.
1975-01-01
The objective of the JT8D refan program was to design, fabricate, and test certifiable modifications of the JT8D engine which would reduce noise generated by JT8D powered aircraft. This was to be accomplished without affecting reliability and maintainability, at minimum retrofit cost, and with no performance penalty. The mechanical design, engine performance and stability characteristics at sea-level and altitude, and the engine noise characteristics of the test engines are documented. Results confirmed the structural integrity of the JT8D-109. Engine operation was stable throughout the airplane flight envelope. Fuel consumption of the test engines was higher than that required to meet the goal of no airplane performance penalty, but the causes were identified and corrected during a normal pre-certification engine development program. Compared to the baseline JT8D-109 engine, the acoustically treated JT8D-109 engine showed noise reductions of 6 PNdB at takeoff and 11 PNdB at a typical approach power setting.
Key Policy Makers' Awareness of Tobacco Taxation Effectiveness through a Sensitization Program.
Heydari, Gholamreza; Ebn Ahmady, Arezoo; Lando, Harry A; Chamyani, Fahimeh; Masjedi, Mohammadreza; Shadmehr, Mohammad B; Fadaizadeh, Lida
2015-12-01
The implementation of 5 of the 6 WHO MPOWER program in Iran is satisfactory; the only notable shortcoming is the lack of tobacco taxation increases. This study was designed to increase key policy makers' awareness of tobacco taxation effectiveness through a sensitization program in Iran. This analytical and semi-experimental study in 2014 included 110 tobacco control key policy makers, who were trained and received educational materials on the importance of tobacco taxation. A valid and reliable questionnaire was completed before and three months after intervention. Data were analyzed using mean (SD), t-Test and analysis of variance. The mean (SD) scores at pre- and post-test were 2.7 ± 3 and 8.8 ± 1 out of 10, respectively. Paired t-tests demonstrated a significant difference in the pre- post-test knowledge scores. Increasing knowledge and promoting favorable attitudes of policy makers can lead to greater attention which could in turn change tobacco taxation policies.
Estimating forestland area change from inventory data
Paul Van Deusen; Francis Roesch; Thomas Wigley
2013-01-01
Simple methods for estimating the proportion of land changing from forest to nonforest are developed. Variance estimators are derived to facilitate significance tests. A power analysis indicates that 400 inventory plots are required to reliably detect small changes in net or gross forest loss. This is an important result because forest certification programs may...
10 CFR 712.11 - General requirements for HRP certification.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 10 Energy 4 2014-01-01 2014-01-01 false General requirements for HRP certification. 712.11 Section 712.11 Energy DEPARTMENT OF ENERGY HUMAN RELIABILITY PROGRAM Establishment of and Procedures for the... provisions of 10 CFR part 707 for DOE contractors, and DOE Order 3792.3, “Drug-Free Federal Workplace Testing...
USDA-ARS?s Scientific Manuscript database
Vaccination against avian influenza (AI) virus, a powerful tool for control of the disease, may result in issues related to surveillance programs and international trade of poultry and poultry products. The use of AI vaccination in poultry would have greater world-wide acceptance if a reliable test...
Space shuttle program: Shuttle Avionics Integration Laboratory. Volume 7: Logistics management plan
NASA Technical Reports Server (NTRS)
1974-01-01
The logistics management plan for the shuttle avionics integration laboratory defines the organization, disciplines, and methodology for managing and controlling logistics support. Those elements requiring management include maintainability and reliability, maintenance planning, support and test equipment, supply support, transportation and handling, technical data, facilities, personnel and training, funding, and management data.
Examining the Quality of IEPs for Young Children with Autism
ERIC Educational Resources Information Center
Ruble, Lisa A.; McGrew, John; Dalrymple, Nancy; Jung, Lee Ann
2010-01-01
The purpose of this study was to develop an Individual Education Program (IEP) evaluation tool based on Individuals with Disabilities Education Act (IDEA) requirements and National Research Council recommendations for children with autism; determine the tool's reliability; test the tool on a pilot sample of IEPs of young children; and examine…
NASA Technical Reports Server (NTRS)
1979-01-01
Contractor information requirements necessary to support the power extension package project of the space shuttle program are specified for the following categories of data: project management; configuration management; systems engineering and test; manufacturing; reliability, quality assurance and safety; logistics; training; and operations.
Visual inspection reliability of transport aircraft
NASA Astrophysics Data System (ADS)
Spencer, Floyd W.
1996-11-01
The Federal Aviation Administration Technical Center has sponsored a visual inspection reliability program at its airworthiness assurance nondestructive inspection validation center (AANC). We report on the results of the benchmark phase of that program in which 12 inspectors were observed in two days of inspections on a Boeing 737 aircraft. All of the inspectors were currently employed with major airlines and all had experience inspecting the Boeing 737 aircraft. Each inspector spent 2 days at the AANC facility where they inspected to the same ten job cards. Each inspector was videotaped and all nonroutine repair actions were recorded for each inspector. Background information on each of the inspectors, including vision test results, was also gathered. The inspection results were correlated with the background variables. Aviation experience and a test time reflecting visual acuity were significantly correlated with performance factors. An analysis of the video tapes was performed to separate decision errors from search errors. Probability of detection curves were fit to the results of inspecting for cracks from beneath rivet heads in a task using prepared samples with known cracks.
Clayson, Peter E; Miller, Gregory A
2017-01-01
Failing to consider psychometric issues related to reliability and validity, differential deficits, and statistical power potentially undermines the conclusions of a study. In research using event-related brain potentials (ERPs), numerous contextual factors (population sampled, task, data recording, analysis pipeline, etc.) can impact the reliability of ERP scores. The present review considers the contextual factors that influence ERP score reliability and the downstream effects that reliability has on statistical analyses. Given the context-dependent nature of ERPs, it is recommended that ERP score reliability be formally assessed on a study-by-study basis. Recommended guidelines for ERP studies include 1) reporting the threshold of acceptable reliability and reliability estimates for observed scores, 2) specifying the approach used to estimate reliability, and 3) justifying how trial-count minima were chosen. A reliability threshold for internal consistency of at least 0.70 is recommended, and a threshold of 0.80 is preferred. The review also advocates the use of generalizability theory for estimating score dependability (the generalizability theory analog to reliability) as an improvement on classical test theory reliability estimates, suggesting that the latter is less well suited to ERP research. To facilitate the calculation and reporting of dependability estimates, an open-source Matlab program, the ERP Reliability Analysis Toolbox, is presented. Copyright © 2016 Elsevier B.V. All rights reserved.
NASA Technical Reports Server (NTRS)
Barr, Stephanie
2009-01-01
There have been a number of studies done in the past drawn on lessons learned with regard to human loss-of-life events. Generally, the systemic causes and proximate causes for fatal events have both been examined in considerable detail. However, an examination of near-fatal accidents and failures that narrowly missed being fatal could be equally useful, not only in detecting causes, both proximate and systemic, but also for determining what factors averted disaster, what design decisions and/or operator actions prevented catastrophe. Additionally, review of risk factors for upcoming or future programs will often look at trending statistics, generally focusing on failure/success statistics. Unfortunately, doing so can give a skewed or misleading view of past reliability or a reliability that cannot be presumed to apply to a new program. One reason for this might be that failure/success criteria aren't the same across programs, but also that apparent success can hide systemic faults that, under other circumstances, can be fatal to a program with different parameters. A program with a number of near misses can look more reliable than a consistently healthy program with a single out-of-family failure and provide very misleading data if it is not examined in detail. This is particularly true for a manned space program where failure/success includes more than making a particular orbit. Augmenting reliability evaluations with this near miss data can provide insight and expand on the limitations of a strictly pass/fail evaluation. Even more importantly, a thorough understanding of these near miss events can identify conditions that prevented fatalities. Those conditions may be key to a programs reliability, but, without insight to the repercussions if such conditions were not in place, their importance may not be readily clear. As programs mature and political and fiscal responsibilities come to the fore, often there is considerable incentive to eliminate unnecessary conservatism, design margin, redundancy, operational support, testing, training, or safety oversight. An evaluation that demonstrates how these features and capabilities averted disaster can ensure processes that saved lives or missions are not discarded without appropriate review and understanding. Close examination of accidents that almost were can also highlight differences in design from one program to another, either justifying reliability comparisons or negating them. It can also provide considerable insight into how those saving factors were developed and implemented so that similar methods can be used to ensure appropriate life-saving and mission saving factors can be developed, even for a dissimilar space program. The lessons are appropriate for seasoned manned space programs and agencies, but crucial for untried agencies and organizations that are interested in sending man into space. The large body of publicly available near miss and accident data available provide invaluable insight into programmatic, technical, and even political issues that can be addressed before they impact safety. In this paper, we examine a number of these near misses and accidents and steps a program, agency, or potential spacefaring company might take to improve their chances of success and avoid mission or safety disasters using this data.
Chen, Y-W; HajGhanbari, B; Road, J D; Coxson, H O; Camp, P G; Reid, W D
2018-06-08
Pain is prevalent in chronic obstructive pulmonary disease (COPD) and the Brief Pain Inventory (BPI) appears to be a feasible questionnaire to assess this symptom. However, the reliability and validity of the BPI have not been determined in individuals with COPD. This study aimed to determine the internal consistency, test-retest reliability and validity (construct, convergent, divergent and discriminant) of the BPI in individuals with COPD. In order to examine the test-retest reliability, individuals with COPD were recruited from pulmonary rehabilitation programmes to complete the BPI twice 1 week apart. In order to investigate validity, de-identified data was retrieved from two previous studies, including forced expiratory volume in 1-s, age, sex and data from four questionnaires: the BPI, short-form McGill Pain Questionnaire (SF-MPQ), 36-Item Short Form Survey (SF-36) and Community Health Activities Model Program for Seniors (CHAMPS) questionnaire. In total, 123 participants were included in the analyses (eligible data were retrieved from 86 participants and additional 37 participants were recruited). The BPI demonstrated excellent internal consistency and test-retest reliability. It also showed convergent validity with the SF-MPQ and divergent validity with the SF-36. The factor analysis yielded two factors of the BPI, which demonstrated that the two domains of the BPI measure the intended constructs. The BPI can also discriminate pain levels among COPD patients with varied levels of quality of life (SF-36) and physical activity (CHAMPS). The BPI is a reliable and valid pain questionnaire that can be used to evaluate pain in COPD. This study formally established the reliability and validity of the BPI in individuals with COPD, which have not been determined in this patient group. The results of this study provide strong evidence that assessment results from this pain questionnaire are reliable and valid. © 2018 European Pain Federation - EFIC®.
Menson, William Nii Ayitey; Olawepo, John Olajide; Bruno, Tamara; Gbadamosi, Semiu Olatunde; Nalda, Nannim Fazing; Anyebe, Victor; Ogidi, Amaka; Onoka, Chima; Oko, John Okpanachi; Ezeanolue, Echezona Edozie
2018-03-01
mHealth practitioners seek to leverage the ubiquity of the mobile phone to increase the impact and robustness of their interventions, particularly in resource-limited settings. However, data on the reliability of self-reported mobile phone access is minimal. We sought to ascertain the reliability of self-reported ownership of and access to mobile phones among a population of rural dwellers in north-central Nigeria. We contacted participants in a community-based HIV testing program by phone to determine actual as opposed to self-reported mobile phone access. A phone script was designed to conduct these calls and descriptive analyses conducted on the findings. We dialed 349 numbers: 110 (31.5%) were answered by participants who self-reported ownership of the mobile phone; 123 (35.2%) of the phone numbers did not ring at all; 28 (8.0%) rang but were not answered; and 88 (25.2%) were answered by someone other than the participant. We reached a higher proportion of male participants (68/133, 51.1%) than female participants (42/216, 19.4%; P<.001). Self-reported access to mobile phones in rural and low-income areas in north-central Nigeria is higher than actual access. This has implications for mHealth programming, particularly for women's health. mHealth program implementers and researchers need to be cognizant of the low reliability of self-reported mobile phone access. These observations should therefore affect sample-size calculations and, where possible, alternative means of reaching research participants and program beneficiaries should be established. ©William Nii Ayitey Menson, John Olajide Olawepo, Tamara Bruno, Semiu Olatunde Gbadamosi, Nannim Fazing Nalda, Victor Anyebe, Amaka Ogidi, Chima Onoka, John Okpanachi Oko, Echezona Edozie Ezeanolue. Originally published in JMIR Mhealth and Uhealth (http://mhealth.jmir.org), 01.03.2018.
NASA Technical Reports Server (NTRS)
Lathrop, J. W.
1985-01-01
If thin film cells are to be considered a viable option for terrestrial power generation their reliability attributes will need to be explored and confidence in their stability obtained through accelerated testing. Development of a thin film accelerated test program will be more difficult than was the case for crystalline cells because of the monolithic construction nature of the cells. Specially constructed test samples will need to be fabricated, requiring committment to the concept of accelerated testing by the manufacturers. A new test schedule appropriate to thin film cells will need to be developed which will be different from that used in connection with crystalline cells. Preliminary work has been started to seek thin film schedule variations to two of the simplest tests: unbiased temperature and unbiased temperature humidity. Still to be examined are tests which involve the passage of current during temperature and/or humidity stress, either by biasing in the forward (or reverse) directions or by the application of light during stress. Investigation of these current (voltage) accelerated tests will involve development of methods of reliably contacting the thin conductive films during stress.
NASA preferred reliability-practices for design and test
NASA Technical Reports Server (NTRS)
Lisk, Ronald C.
1992-01-01
NASA HQ established the NASA R&M Steering Committee (R&MSC) comprised of membership from each NASA field center. The primary charter of the R&MSC is to obtain, record, and share the best design practices that NASA has applied to successful space flight programs and current design considerations (guidelines) that should enhance flight reliability on emerging programs. The practices and guidelines are being assembled in a living document for distribution to NASA centers and the aerospace community. The document will be updated annually with additional practices and guidelines as contributions from the centers are reviewed and approved by the R&MSC. Practices and guidelines are not requirements, but rather a means of sharing procedures and techniques that a given center and the R&MSC together feel have strong technical merit and application to the design of space-related equipment.
NASA presentation. [wind energy conversion systems planning
NASA Technical Reports Server (NTRS)
Thomas, R. L.
1973-01-01
The development of a wind energy system is outlined that supplies reliable energy at a cost competitive with other energy systems. A government directed industry program with strong university support is recommended that includes meteorological studies to estimate wind energy potentials and determines favorable regions and sites for wind power installations. Key phases of the overall program are wind energy conversion systems, meteorological wind studies, energy storage systems, and environmental impact studies. Performance testing with a prototype wind energy conversion and storage system is projected for Fiscal 1977.
Technology Innovations from NASA's Next Generation Launch Technology Program
NASA Technical Reports Server (NTRS)
Cook, Stephen A.; Morris, Charles E. K., Jr.; Tyson, Richard W.
2004-01-01
NASA's Next Generation Launch Technology Program has been on the cutting edge of technology, improving the safety, affordability, and reliability of future space-launch-transportation systems. The array of projects focused on propulsion, airframe, and other vehicle systems. Achievements range from building miniature fuel/oxygen sensors to hot-firings of major rocket-engine systems as well as extreme thermo-mechanical testing of large-scale structures. Results to date have significantly advanced technology readiness for future space-launch systems using either airbreathing or rocket propulsion.
Design of ceramic components with the NASA/CARES computer program
NASA Technical Reports Server (NTRS)
Nemeth, Noel N.; Manderscheid, Jane M.; Gyekenyesi, John P.
1990-01-01
The ceramics analysis and reliability evaluation of structures (CARES) computer program is described. The primary function of the code is to calculate the fast-fracture reliability or failure probability of macro-scopically isotropic ceramic components. These components may be subjected to complex thermomechanical loadings, such as those found in heat engine applications. CARES uses results from MSC/NASTRAN or ANSYS finite-element analysis programs to evaluate how inherent surface and/or volume type flaws component reliability. CARES utilizes the Batdorf model and the two-parameter Weibull cumulative distribution function to describe the effects of multiaxial stress states on material strength. The principle of independent action (PIA) and the Weibull normal stress averaging models are also included. Weibull material strength parameters, the Batdorf crack density coefficient, and other related statistical quantities are estimated from four-point bend bar or uniform uniaxial tensile specimen fracture strength data. Parameter estimation can be performed for a single or multiple failure modes by using a least-squares analysis or a maximum likelihood method. Kolmogorov-Smirnov and Anderson-Darling goodness-to-fit-tests, 90 percent confidence intervals on the Weibull parameters, and Kanofsky-Srinivasan 90 percent confidence band values are also provided. Examples are provided to illustrate the various features of CARES.
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1996-06-01
This report documents the second phase of the Remote Operated Vehicle with CO{sub 2} Blasting (ROVCO{sub 2}) Program. The ROVCO{sub 2} Program`s goal is to develop and demonstrate a tool to improve the productivity of concrete floor decontamination. The second phase integrated non-developmental subsystems on to the ROVCO{sub 2} system and performed quantitative decontamination effectiveness, productivity, and reliability testings. The report documents these development activities and the analysis of cost and performance. The results show that the ROVCO{sub 2} system is an efficient decontamination tool.
Examples of Nonconservatism in the CARE 3 Program
NASA Technical Reports Server (NTRS)
Dotson, Kelly J.
1988-01-01
This paper presents parameter regions in the CARE 3 (Computer-Aided Reliability Estimation version 3) computer program where the program overestimates the reliability of a modeled system without warning the user. Five simple models of fault-tolerant computer systems are analyzed; and, the parameter regions where reliability is overestimated are given. The source of the error in the reliability estimates for models which incorporate transient fault occurrences was not readily apparent. However, the source of much of the error for models with permanent and intermittent faults can be attributed to the choice of values for the run-time parameters of the program.
Software For Computing Reliability Of Other Software
NASA Technical Reports Server (NTRS)
Nikora, Allen; Antczak, Thomas M.; Lyu, Michael
1995-01-01
Computer Aided Software Reliability Estimation (CASRE) computer program developed for use in measuring reliability of other software. Easier for non-specialists in reliability to use than many other currently available programs developed for same purpose. CASRE incorporates mathematical modeling capabilities of public-domain Statistical Modeling and Estimation of Reliability Functions for Software (SMERFS) computer program and runs in Windows software environment. Provides menu-driven command interface; enabling and disabling of menu options guides user through (1) selection of set of failure data, (2) execution of mathematical model, and (3) analysis of results from model. Written in C language.
NASA Astrophysics Data System (ADS)
Fisher, W. P., Jr.; Elbaum, B.; Coulter, A.
2010-07-01
Reliability coefficients indicate the proportion of total variance attributable to differences among measures separated along a quantitative continuum by a testing, survey, or assessment instrument. Reliability is usually considered to be influenced by both the internal consistency of a data set and the number of items, though textbooks and research papers rarely evaluate the extent to which these factors independently affect the data in question. Probabilistic formulations of the requirements for unidimensional measurement separate consistency from error by modelling individual response processes instead of group-level variation. The utility of this separation is illustrated via analyses of small sets of simulated data, and of subsets of data from a 78-item survey of over 2,500 parents of children with disabilities. Measurement reliability ultimately concerns the structural invariance specified in models requiring sufficient statistics, parameter separation, unidimensionality, and other qualities that historically have made quantification simple, practical, and convenient for end users. The paper concludes with suggestions for a research program aimed at focusing measurement research more on the calibration and wide dissemination of tools applicable to individuals, and less on the statistical study of inter-variable relations in large data sets.
Development of Face Gear Technology for Industrial and Aerospace Power Transmission
NASA Technical Reports Server (NTRS)
Heath, Gregory F.; Filler, Robert R.; Tan, Jie
2002-01-01
Tests of a 250 horsepower proof-of-concept (POC) split torque face gear transmission were completed by The Boeing Company in Mesa, Arizona, while working under a Defense Advanced Research Projects Agency (DARPA) Technology Reinvestment Program (TRP) This report provides a summary of these cooperative tests, which were jointly funded by Boeing and DARPA Design, manufacture and testing of the scaled-power TRP split torque gearbox followed preliminary evaluations of the concept performed early in the program The testing demonstrated the theory of operation for the concentric, tapered face gear assembly The results showed that the use of floating pinions in a concentric face gear arrangement produces a nearly even torque split The POC split torque tests determined that, with some improvements, face gears can be applied effectively in a split torque configuration which yields significant weight, cost and reliability improvements over conventional designs.
Bai, Yeon; Peng, C-Y Joanne; Fly, Alyce D
2008-07-01
The purpose of this study was to create and establish the validity of a short questionnaire to measure mothers' perceived support for breastfeeding from the workplace. The items in the workplace breastfeeding support scale (WBSS) were derived from a literature review. The scale was self-administered in central Indiana during the fall of 2005 to a convenience sample of 66 volunteers who were primiparous, 6 to 12 months postpartum, worked outside home, and had initiated breastfeeding prior to the survey. Internal consistency (alpha) and split-half reliability (r) tests and a factor analysis were done to establish reliability and construct validity of the scale. The WBSS showed acceptable reliability (alpha=.77, r=0.86). Content validity was established by review using a panel of experts. Four distinct constructs of the scale were identified that accounted for 62.1% of the total variability of the scale: technical, environmental, facility, and peer support, thus establishing construct validity of the scale. Lactation consultants and worksite lactation program planners can use the WBSS to help mothers returning to work and to assess the needs for improvement of support programs.
The implementation and use of Ada on distributed systems with high reliability requirements
NASA Technical Reports Server (NTRS)
Knight, J. C.
1986-01-01
The use and implementation of Ada in distributed environments in which reliability is the primary concern were investigted. A distributed system, programmed entirely in Ada, was studied to assess the use of individual tasks without concern for the processor used. Continued development and testing of the fault tolerant Ada testbed; development of suggested changes to Ada to cope with the failures of interest; design of approaches to fault tolerant software in real time systems, and the integration of these ideas into Ada; and the preparation of various papers and presentations were discussed.
An assessment of laser velocimetry in hypersonic flow
NASA Technical Reports Server (NTRS)
1992-01-01
Although extensive progress has been made in computational fluid mechanics, reliable flight vehicle designs and modifications still cannot be made without recourse to extensive wind tunnel testing. Future progress in the computation of hypersonic flow fields is restricted by the need for a reliable mean flow and turbulence modeling data base which could be used to aid in the development of improved empirical models for use in numerical codes. Currently, there are few compressible flow measurements which could be used for this purpose. In this report, the results of experiments designed to assess the potential for laser velocimeter measurements of mean flow and turbulent fluctuations in hypersonic flow fields are presented. Details of a new laser velocimeter system which was designed and built for this test program are described.
Bremer, James; Bertagnolio, Silvia
2012-01-01
The World Health Organization (WHO) has developed a global laboratory network to support human immunodeficiency virus drug resistance genotyping for public health surveillance in resource-limited countries. Blinded proficiency panels are an essential part of a genotyping quality-assurance program and are used to monitor the reliability of genotyping data in the WHO laboratory network. Laboratories in Europe, North America, Asia, Africa, and the Caribbean have tested panels annually since 2007; 103 of 131 submissions (79%) had >99% nucleotide sequence identity and resistance mutation concordance, compared with consensus. Most errors were associated with mixtures in the test specimen, leading to subjectivity in base-calling or amplification bias. Overall, genotyping assays used by the WHO laboratory network are reliable. PMID:22544186
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1980-06-01
Beginning in February, 1970, the Nuclear Materials and Equipment Corporation (NUMEC) undertook a program to design, develop and manufacture a radioisotope powered cardiac pacemaker system. The scope of technical work was specified to be: establish system, component, and process cost reduction goals using the prototype Radioisotope Powered Cardiac Pacemaker (RCP) design and develop production techniques to achieve these cost reduction objectives; fabricate radioisotope powered fueled prototype cardiac pacemakers (RCP's) on a pilot production basis; conduct liaison with a Government-designated fueling facility for purposes of defining fueling requirements, fabrication and encapsulation procedures, safety design criteria and quality control and inspection requirements;more » develop and implement Quality Assurance and Reliability Programs; conduct performance, acceptance, lifetime and reliability tests of fueled RCP's in the laboratory; conduct liaison with the National Institutes of Health and with Government specified medical research institutions selected for the purpose of undertaking clinical evaluation of the RCP in humans; monitor and evaluate, on a continuing basis, all test data; and perform necessary safety analyses and tests. Pacemaker designs were developed and quality assurance and manufacturing procedures established. Prototype pacemakers were fabricated. A total of 126 radioisotope powered units were implanted and have been followed clinically for approximately seven years. Four (4) of these units have failed. Eighty-three (83) units remain implanted and satisfactorily operational. An overall failure rate of less than the target 0.15% per month has been achieved.« less
Development and validation of the Geriatric In-hospital Nursing Care Questionnaire.
Persoon, Anke; Bakker, Franka C; van der Wal-Huisman, Hanneke; Olde Rikkert, Marcel G M
2015-02-01
To develop a questionnaire, the Geriatric In-hospital Nursing Care Questionnaire (GerINCQ), to measure, in an integrated way, the care that older adults receive in the hospital and nurses' attitudes toward and perceptions about caring for older adults. Questionnaire development. Twelve university and teaching hospitals. Thirteen experienced geriatric nurses and three geriatricians from 12 hospitals evaluated an initial version of the questionnaire. Two hundred seventy-one nurses, primarily registered nurses from 11 geriatric, medical, and surgical departments in six hospitals, validated the final questionnaire. Items from two published instruments were extracted for use in the questionnaire. Content validity was confirmed using the Delphi technique with an expert panel. Internal consistency was measured by calculating Cronbach alpha; intrarater reliability was measured using test-retest correlations and intraclass correlation coefficients (ICCs); differences between hospital departments were analyzed using analysis of variance. Sensitivity to detect before-and-after changes with implementation of a geriatric care program was determined using the Student t-test. Consensus was reached after three Delphi rounds. The GerINCQ is a self-administered questionnaire to be filled out by hospital nurses that comprises five subscales with 67 items. It has good content validity (each item content validity index >0.9) and good internal consistency (Cronbach alpha = 0.86). Intrarater reliability revealed high test-retest results (ICC = 0.87). The questionnaire detected significant differences between nurses in three types of hospital departments (medical, surgical, and geriatric (P < .01). The GerINCQ was sensitive to changes after an educational program (P < .02) and had a large effect size (0.5). The GerINCQ is a reliable and valid tool and is sensitive to change over time. It is clinically relevant because it provides a quantitative measure of hospital nurses' geriatric practices, attitudes, and perceptions. Moreover, the GerINCQ is suitable for monitoring progress after implementation of geriatric improvement programs. © 2015, Copyright the Authors Journal compilation © 2015, The American Geriatrics Society.
Neil, Sarah E; Myring, Alec; Peeters, Mon Jef; Pirie, Ian; Jacobs, Rachel; Hunt, Michael A; Garland, S Jayne; Campbell, Kristin L
2013-11-01
Muscular strength is a key parameter of rehabilitation programs and a strong predictor of functional capacity. Traditional methods to measure strength, such as manual muscle testing (MMT) and hand-held dynamometry (HHD), are limited by the strength and experience of the tester. The Performance Recorder 1 (PR1) is a strength assessment tool attached to resistance training equipment and may be a time- and cost-effective tool to measure strength in clinical practice that overcomes some limitations of MMT and HHD. However, reliability and validity of the PR1 have not been reported. Test-retest and inter-rater reliability was assessed using the PR1 in healthy adults (n = 15) during isometric knee flexion and extension. Criterion-related validity was assessed through comparison of values obtained from the PR1 and Biodex® isokinetic dynamometer. Test-retest reliability was excellent for peak knee flexion (intra-class correlation coefficient [ICC] of 0.96, 95% CI: 0.85, 0.99) and knee extension (ICC = 0.96, 95% CI: 0.87, 0.99). Inter-rater reliability was also excellent for peak knee flexion (ICC = 0.95, 95% CI: 0.85, 0.99) and peak knee extension (ICC = 0.97, 95% CI: 0.91, 0.99). Validity was moderate for peak knee flexion (ICC = 0.75, 95% CI: 0.38, 0.92) but poor for peak knee extension (ICC = 0.37, 95% CI: 0, 0.73). The PR1 provides a reliable measure of isometric knee flexor and extensor strength in healthy adults that could be used in the clinical setting, but absolute values may not be comparable to strength assessment by gold-standard measures.
Roth, Ralf; Donath, Lars; Kurz, Eduard; Zahner, Lukas; Faude, Oliver
2017-03-01
The present study aimed to assess the between day reliability of isokinetic and isometric peak torque (PT) during trunk measurement on an isokinetic device (IsoMed 2000). Test-retest-protocol on five separate days. Fifteen healthy sport students (8 female and 7 male) aged 21 to 26. PT was assessed in isometric back extension and flexion as well as right and left rotation. Isokinetic strength was captured at a speed of 60°/s and 150°/s for all tasks. For none of the assessed parameters a meaningful variation in PT during test days was observed. Relative reliability (ICC = 0.85-0.96) was excellent for all tasks. Estimates of absolute reliability as Coefficient of Variation (CoV) and Standard Error of Measurement (SEM in Nm/kg lean body mass) remained stable for isometric (6.9% < CoV < 9.4%; 0.15 < SEM < 0.23) and isokinetic mode (60°/s: 3.7% < CoV < 8.6%; 0.08 < SEM < 0.24; 150°/s: 6.9% < CoV < 12.4%; 0.10 < SEM < 0.31). In contrast, reliability between familiarization day and day 1 was lower (6.6% < CoV < 26.2%; 0.10 < SEM < 0.65). Trunk strength measurement in flexion and extension or trunk rotation in either isometric or isokinetic condition is highly reliable. Therefore, it seems possible to elucidate changes which are smaller than 10% due to intervention programs when a preceding familiarization condition was applied. Copyright © 2016 Elsevier Ltd. All rights reserved.
Wiseman, Nicola; Harris, Neil; Downes, Martin
2017-02-01
Preschool children's knowledge of, and preference for food and physical activity play an important role in the development of lifestyle behaviors throughout childhood. Valid and reliable instruments that are interactive and appealing to preschool children are needed, to obtain quality information in a way that actively engages children and encourages willing participation. The purpose of the current research is to assess the reliability and validity of an adapted computerized (iPad) version of the photo-pair food and exercise questionnaire (PPFEQ). The adaptation of the PPFEQ involved generating the questionnaire as an iPad-based tool, updating the photo-pairs within the questionnaire and testing for validity and reliability. This involved four phases of investigation to assess test-retest reliability, internal consistency, sensitivity to change and percent agreement of the questionnaire. The adaption of the PPFEQ resulted in an 18-item questionnaire, titled the preschool food and play questionnaire (Pre-FPQ). The Pre-FPQ demonstrated acceptable reliability and sensitivity to change. Test-retest reliability and internal consistency improved with age, however, it was evident that the tool was not suitable for children younger than 4 years of age. Children encounter a dynamic world that shapes their knowledge, preferences, choices and behaviors. The Pre-FPQ is an innovative tool to measure preschool children's knowledge of and preference for food and physical activity. The questionnaire offers the advantage of being presented in a well-received modality for preschool children as well as being easy and inexpensive to administer. This new tool is likely to be useful for the assessment of the effectiveness of healthy lifestyle programs implemented in the childcare setting. Future work is needed to refine and improve measures of physical activity preference in preschool children.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Coates, Cameron W; Eisele, Gerhard R
2011-01-01
The Russian Federation (RF) is committed to implementing a comprehensive drug testing program under its Personnel Reliability Program (PRP) for military personnel involved in handling sensitive nuclear materials. This commitment leads to a number of mandatory requirements for the laboratory conducting the confirmation testing to ensure the legitimacy and integrity of the testing process. These requirements are established by the RF Duma to ensure that individuals conducting these tests have adequate training, certifications, and experience to conduct narcotic confirmation tests. This paper describes the facility requirements and personnel qualifications needed for conducting comprehensive drug abuse confirmation testing. Details regarding themore » personnel training and laboratory experience in the theory and practice of analytical forensic toxicology of drugs of abuse will be presented, as well as the facility requirements for the laboratory conducting such tests. Chain-of-custody, from sample receipt through completion of testing, reporting of results, and continuing until final disposition of specimens will be addressed.« less
NASA Astrophysics Data System (ADS)
Kerrison, Dorothy Adair
The primary objective of this pilot study is to provide evidence that a budget-tailored culinary nutrition program is both appropriate and applicable to undergraduate food science students both in everyday life as well as their future health careers. Two validated programs were combined into one program in order to evaluate their combined effects: Cooking With a Chef and Cooking Matters at the Store. The secondary objective of this pilot study is to evaluate the components and reliability of a questionnaire created specifically for this pilot study. A review of past literature was written, which included culinary nutrition as a source of primary prevention, the importance of incorporating cost with culinary nutrition, and the importance of incorporating cost with culinary nutrition. Based on the literature review, it was determined that a budget-tailored culinary nutrition program was appropriate and applicable to undergraduate food science students interested in pursuing health-related careers. The pilot study design was a semi-crossover study: all four groups received the program, however, two groups were first treated as the control groups. All fifty-four participants received 5 sessions of culinary nutrition information from Cooking With a Chef, collaboratively delivered by a nutrition educator and a chef, and one session of information about shopping healthy on a budget from Cooking Matters at the Store in the form of a grocery store tour led by the nutrition educator. Three questionnaires were administered to the participants that evaluated culinary nutrition and price knowledge, cooking attitudes, and opinions of the programs' relevance to participants' everyday lives and careers. Two of the questionnaires, including a questionnaire developed specifically for the pilot study, were delivered as a pre- and post-test while the third questionnaire was delivered as a post-test. Eight random participants also partook in a focus group session led by the nutrition educator. Based on statistical results, there were significant differences between the treatment group and control group in Cooking Self-Efficacy (p=0.0024), Self-Efficacy for Using Basic Cooking Techniques (p=<0.0001), Self-Efficacy for Using Fruits, Vegetables, and Seasonings (p=<0.0001), and the ability to use economical methods to purchase low-cost produce and identify different forms of produce (p=<0.0001). For the one-time post-program administered questionnaire, the participants received an average score of 89.44 percent. The reliability procedure performed on the pilot study questionnaire showed that 13 of the 15 items were statistically reliable (p<0.05). The factor analysis procedure performed showed that there were five factors within the pilot study questionnaire. Participant responses from the focus group included how the program was a positive change from other mandatory courses, reaffirmed or increased interest in their major(s) and applied both to their everyday life and future career. This pilot study demonstrates preliminary results of the effects of combining culinary nutrition information with budget and price concepts to deliver to undergraduate food science students. The significance of understanding both culinary nutrition and price is important in order to effectively deliver nutrition counseling to patients of all different demographics. Additional testing and modification could be performed on the curriculum as well as the pilot study questionnaire in order to effectively relate the instrument to the program and increase the instrument's reliability.
Mass and Reliability System (MaRS)
NASA Technical Reports Server (NTRS)
Barnes, Sarah
2016-01-01
The Safety and Mission Assurance (S&MA) Directorate is responsible for mitigating risk, providing system safety, and lowering risk for space programs from ground to space. The S&MA is divided into 4 divisions: The Space Exploration Division (NC), the International Space Station Division (NE), the Safety & Test Operations Division (NS), and the Quality and Flight Equipment Division (NT). The interns, myself and Arun Aruljothi, will be working with the Risk & Reliability Analysis Branch under the NC Division's. The mission of this division is to identify, characterize, diminish, and communicate risk by implementing an efficient and effective assurance model. The team utilizes Reliability and Maintainability (R&M) and Probabilistic Risk Assessment (PRA) to ensure decisions concerning risks are informed, vehicles are safe and reliable, and program/project requirements are realistic and realized. This project pertains to the Orion mission, so it is geared toward a long duration Human Space Flight Program(s). For space missions, payload is a critical concept; balancing what hardware can be replaced by components verse by Orbital Replacement Units (ORU) or subassemblies is key. For this effort a database was created that combines mass and reliability data, called Mass and Reliability System or MaRS. The U.S. International Space Station (ISS) components are used as reference parts in the MaRS database. Using ISS components as a platform is beneficial because of the historical context and the environment similarities to a space flight mission. MaRS uses a combination of systems: International Space Station PART for failure data, Vehicle Master Database (VMDB) for ORU & components, Maintenance & Analysis Data Set (MADS) for operation hours and other pertinent data, & Hardware History Retrieval System (HHRS) for unit weights. MaRS is populated using a Visual Basic Application. Once populated, the excel spreadsheet is comprised of information on ISS components including: operation hours, random/nonrandom failures, software/hardware failures, quantity, orbital replaceable units (ORU), date of placement, unit weight, frequency of part, etc. The motivation for creating such a database will be the development of a mass/reliability parametric model to estimate mass required for replacement parts. Once complete, engineers working on future space flight missions will have access a mean time to failures and on parts along with their mass, this will be used to make proper decisions for long duration space flight missions
Reliability of an interactive computer program for advance care planning.
Schubart, Jane R; Levi, Benjamin H; Camacho, Fabian; Whitehead, Megan; Farace, Elana; Green, Michael J
2012-06-01
Despite widespread efforts to promote advance directives (ADs), completion rates remain low. Making Your Wishes Known: Planning Your Medical Future (MYWK) is an interactive computer program that guides individuals through the process of advance care planning, explaining health conditions and interventions that commonly involve life or death decisions, helps them articulate their values/goals, and translates users' preferences into a detailed AD document. The purpose of this study was to demonstrate that (in the absence of major life changes) the AD generated by MYWK reliably reflects an individual's values/preferences. English speakers ≥30 years old completed MYWK twice, 4 to 6 weeks apart. Reliability indices were assessed for three AD components: General Wishes; Specific Wishes for treatment; and Quality-of-Life values (QoL). Twenty-four participants completed the study. Both the Specific Wishes and QoL scales had high internal consistency in both time periods (Knuder Richardson formula 20 [KR-20]=0.83-0.95, and 0.86-0.89). Test-retest reliability was perfect for General Wishes (κ=1), high for QoL (Pearson's correlation coefficient=0.83), but lower for Specific Wishes (Pearson's correlation coefficient=0.57). MYWK generates an AD where General Wishes and QoL (but not Specific Wishes) statements remain consistent over time.
Reliability of an Interactive Computer Program for Advance Care Planning
Levi, Benjamin H.; Camacho, Fabian; Whitehead, Megan; Farace, Elana; Green, Michael J
2012-01-01
Abstract Despite widespread efforts to promote advance directives (ADs), completion rates remain low. Making Your Wishes Known: Planning Your Medical Future (MYWK) is an interactive computer program that guides individuals through the process of advance care planning, explaining health conditions and interventions that commonly involve life or death decisions, helps them articulate their values/goals, and translates users' preferences into a detailed AD document. The purpose of this study was to demonstrate that (in the absence of major life changes) the AD generated by MYWK reliably reflects an individual's values/preferences. English speakers ≥30 years old completed MYWK twice, 4 to 6 weeks apart. Reliability indices were assessed for three AD components: General Wishes; Specific Wishes for treatment; and Quality-of-Life values (QoL). Twenty-four participants completed the study. Both the Specific Wishes and QoL scales had high internal consistency in both time periods (Knuder Richardson formula 20 [KR-20]=0.83–0.95, and 0.86–0.89). Test-retest reliability was perfect for General Wishes (κ=1), high for QoL (Pearson's correlation coefficient=0.83), but lower for Specific Wishes (Pearson's correlation coefficient=0.57). MYWK generates an AD where General Wishes and QoL (but not Specific Wishes) statements remain consistent over time. PMID:22512830
Development of a direct observation Measure of Environmental Qualities of Activity Settings.
King, Gillian; Rigby, Patty; Batorowicz, Beata; McMain-Klein, Margot; Petrenchik, Theresa; Thompson, Laura; Gibson, Michelle
2014-08-01
The aim of this study was to develop an observer-rated measure of aesthetic, physical, social, and opportunity-related qualities of leisure activity settings for young people (with or without disabilities). Eighty questionnaires were completed by sets of raters who independently rated 22 community/home activity settings. The scales of the 32-item Measure of Environmental Qualities of Activity Settings (MEQAS; Opportunities for Social Activities, Opportunities for Physical Activities, Pleasant Physical Environment, Opportunities for Choice, Opportunities for Personal Growth, and Opportunities to Interact with Adults) were determined using principal components analyses. Test-retest reliability was determined for eight activity settings, rated twice (4-6wk interval) by a trained rater. The factor structure accounted for 80% of the variance. The Kaiser-Meyer-Olkin Measure of Sampling Adequacy was 0.73. Cronbach's alphas for the scales ranged from 0.76 to 0.96, and interrater reliabilities (ICCs) ranged from 0.60 to 0.93. Test-retest reliabilities ranged from 0.70 to 0.90. Results suggest that the MEQAS has a sound factor structure and preliminary evidence of internal consistency, interrater, and test-retest reliability. The MEQAS is the first observer-completed measure of environmental qualities of activity settings. The MEQAS allows researchers to assess comprehensively qualities and affordances of activity settings, and can be used to design and assess environmental qualities of programs for young people. © 2014 Mac Keith Press.
Boucher, Jean-Alexandre; Preuss, Richard; Henry, Sharon M; Nugent, Marilee; Larivière, Christian
2018-04-22
Low back pain (LBP) has been previously associated with delayed anticipatory postural adjustments (APAs) determined by trunk muscle activation. Lumbar stabilization exercise programs (LSEP) for patients with LBP may restore the trunk neuromuscular control of the lumbar spine, and normalize APAs. This exploratory study aimed at testing the reliability of EMG and kinematics-based postural adjustment measures over an 8-week interval, assessing their sensitivity to LBP status and treatment and examining their relationship with clinical outcomes. Muscle activation of 10 trunk muscles, using surface electromyography (EMG), and lumbar angular kinematics were recorded during a rapid arm-raising/lowering task. Patients with LBP were tested before and after an 8-week LSEP. Healthy controls receiving no treatment were assessed over the same interval to determine the reliability of the measures and act as a control group at baseline. Muscle activation onsets and reactive range of motion, range of velocities and accelerations were assessed for between group differences at baseline and pre- to post-treatment effects within patients with LBP using t-tests. Correlations between these dependent variables and the change of clinical outcomes (pain, disability) over treatment were also explored. Kinematic-based measures showed comparable reliability to EMG-based measures. Between-group differences were found in lumbar lateral flexion ROM at baseline (patients < controls). In the patients with LBP, lateral flexion velocity and acceleration significantly increased following the LSEP. Correlational analyses revealed that lumbar angular kinematics were more sensitive to changes in pain intensity following the LSEP compared to EMG measures. These findings are interpreted in from the perspective of guarding behaviors and lumbar stability hypotheses. Future clinical trials are needed to target patients with and without delayed APAs at baseline and to explore the sensitivity of different outcome measures related to APAs. Different tasks more challenging to postural stability may need to be explored to more effectively reveal APA dysfunction. Copyright © 2018. Published by Elsevier Ltd.
Bonekamp, S; Ghosh, P; Crawford, S; Solga, S F; Horska, A; Brancati, F L; Diehl, A M; Smith, S; Clark, J M
2008-01-01
To examine five available software packages for the assessment of abdominal adipose tissue with magnetic resonance imaging, compare their features and assess the reliability of measurement results. Feature evaluation and test-retest reliability of softwares (NIHImage, SliceOmatic, Analyze, HippoFat and EasyVision) used in manual, semi-automated or automated segmentation of abdominal adipose tissue. A random sample of 15 obese adults with type 2 diabetes. Axial T1-weighted spin echo images centered at vertebral bodies of L2-L3 were acquired at 1.5 T. Five software packages were evaluated (NIHImage, SliceOmatic, Analyze, HippoFat and EasyVision), comparing manual, semi-automated and automated segmentation approaches. Images were segmented into cross-sectional area (CSA), and the areas of visceral (VAT) and subcutaneous adipose tissue (SAT). Ease of learning and use and the design of the graphical user interface (GUI) were rated. Intra-observer accuracy and agreement between the software packages were calculated using intra-class correlation. Intra-class correlation coefficient was used to obtain test-retest reliability. Three of the five evaluated programs offered a semi-automated technique to segment the images based on histogram values or a user-defined threshold. One software package allowed manual delineation only. One fully automated program demonstrated the drawbacks of uncritical automated processing. The semi-automated approaches reduced variability and measurement error, and improved reproducibility. There was no significant difference in the intra-observer agreement in SAT and CSA. The VAT measurements showed significantly lower test-retest reliability. There were some differences between the software packages in qualitative aspects, such as user friendliness. Four out of five packages provided essentially the same results with respect to the inter- and intra-rater reproducibility. Our results using SliceOmatic, Analyze or NIHImage were comparable and could be used interchangeably. Newly developed fully automated approaches should be compared to one of the examined software packages.
2007-09-09
Under the goals of the Vision for Space Exploration, Ares I is a chief component of the cost-effective space transportation infrastructure being developed by NASA's Constellation Program. This transportation system will safely and reliably carry human explorers back to the moon, and then onward to Mars and other destinations in the solar system. The Ares I effort includes multiple project element teams at NASA centers and contract organizations around the nation, and is managed by the Exploration Launch Projects Office at NASA's Marshall Space Flight Center (MFSC). ATK Launch Systems near Brigham City, Utah, is the prime contractor for the first stage booster. ATK's subcontractor, United Space Alliance of Houston, is designing, developing and testing the parachutes at its facilities at NASA's Kennedy Space Center in Florida. NASA's Johnson Space Center in Houston hosts the Constellation Program and Orion Crew Capsule Project Office and provides test instrumentation and support personnel. Together, these teams are developing vehicle hardware, evolving proven technologies, and testing components and systems. Their work builds on powerful, reliable space shuttle propulsion elements and nearly a half-century of NASA space flight experience and technological advances. Ares I is an inline, two-stage rocket configuration topped by the Crew Exploration Vehicle, its service module, and a launch abort system. In this HD video image, the first stage reentry 1/2% model is undergoing pressure measurements inside the wind tunnel testing facility at MSFC. (Highest resolution available)
Technology verification phase. Dynamic isotope power system. Final report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Halsey, D.G.
1982-03-10
The Phase I requirements of the Kilowatt Isotope Power System (KIPS) program were to make a detailed Flight System Conceptual Design (FSCD) for an isotope fueled organic Rankine cycle power system and to build and test a Ground Demonstration System (GDS) which simulated as closely as possible the operational characteristics of the FSCD. The activities and results of Phase II, the Technology Verification Phase, of the program are reported. The objectives of this phase were to increase system efficiency to 18.1% by component development, to demonstrate system reliability by a 5000 h endurance test and to update the flight systemmore » design. During Phase II, system performance was improved from 15.1% to 16.6%, an endurance test of 2000 h was performed while the flight design analysis was limited to a study of the General Purpose Heat Source, a study of the regenerator manufacturing technique and analysis of the hardness of the system to a laser threat. It was concluded from these tests that the GDS is basically prototypic of a flight design; all components necessary for satisfactory operation were demonstrated successfully at the system level; over 11,000 total h of operation without any component failure attested to the inherent reliability of this type of system; and some further development is required, specifically in the area of performance. (LCL)« less
Dual-Shaft Electric Propulsion (DSEP) Technology Development Program
NASA Astrophysics Data System (ADS)
1992-08-01
The background, progress, and current state of the DOE-sponsored Advanced Dual-Shaft Electric Propulsion Technology Development are presented. Three electric-drive vehicles were build as conversions of a commercial gasoline-powered van, using program-designed components and systems as required. The vehicles were tested primarily on dynamometer or test tract. Component and system testing represented a major portion of the development effort. Test data are summarized in this report, and an Appendix contains the final component design specifications. This major programmatic concerns were the traction battery, the battery management system, the dc-to-ac inverter, the drive motor, the transaxle and its ancillary equipment, and the vehicle controller. Additional effort was devoted to vehicle-related equipment: gear selector, power steering, power brakes, accelerator, dashboard instrumentation, and heater. Design, development, and test activities are reported for each of these items, together with an appraisal (lessons learned) and recommendations for possible further work. Other programmatic results include a Cost and Commercialization Analysis, a Reliability and Hazards Analysis Study, Technical Recommendations for Next-Generation Development, and an assessment of overall program efforts.
Reliability of hybrid microcircuit discrete components
NASA Technical Reports Server (NTRS)
Allen, R. V.
1972-01-01
Data accumulated during 4 years of research and evaluation of ceramic chip capacitors, ceramic carrier mounted active devices, beam-lead transistors, and chip resistors are presented. Life and temperature coefficient test data, and optical and scanning electron microscope photographs of device failures are presented and the failure modes are described. Particular interest is given to discrete component qualification, power burn-in, and procedures for testing and screening discrete components. Burn-in requirements and test data will be given in support of 100 percent burn-in policy on all NASA flight programs.
Leff, Stephen S; Baum, Katherine T; Bevans, Katherine B; Blum, Nathan J
2015-02-01
To describe the development and psychometric evaluation of the Core Competency Measure (CCM), an instrument designed to assess professional competencies as defined by the Maternal Child Health Bureau (MCHB) and targeted by Leadership Education in Neurodevelopmental and Related Disabilities (LEND) programs. The CCM is a 44-item self-report measure comprised of six subscales to assess clinical, interdisciplinary, family-centered/cultural, community, research, and advocacy/policy competencies. The CCM was developed in an iterative fashion through participatory action research, and then nine cohorts of LEND trainees (N = 144) from 14 different disciplines completed the CCM during the first week of the training program. A 6-factor confirmatory factor analysis model was fit to data from the 44 original items. After three items were removed, the model adequately fit the data (comparative fit indices = .93, root mean error of approximation = .06) with all factor loadings exceeding .55. The measure was determined to be quite reliable as adequate internal consistency and test-retest reliability were found for each subscale. The instrument's construct validity was supported by expected differences in self-rated competencies among fellows representing various disciplines, and the convergent validity was supported by the pattern of inter-correlations between subscale scores. The CCM appears to be a reliable and valid measure of MCHB core competencies for our sample of LEND trainees. It provides an assessment of key training areas addressed by the LEND program. Although the measure was developed within only one LEND Program, with additional research it has the potential to serve as a standardized tool to evaluate the strengths and limitations of MCHB training, both within and between programs.
NASA Technical Reports Server (NTRS)
1986-01-01
Activities that will be conducted in support of the development and verification of the Block 2 Solid Rocket Motor (SRM) are described. Development includes design, fabrication, processing, and testing activities in which the results are fed back into the project. Verification includes analytical and test activities which demonstrate SRM component/subassembly/assembly capability to perform its intended function. The management organization responsible for formulating and implementing the verification program is introduced. It also identifies the controls which will monitor and track the verification program. Integral with the design and certification of the SRM are other pieces of equipment used in transportation, handling, and testing which influence the reliability and maintainability of the SRM configuration. The certification of this equipment is also discussed.
Reliability analysis of laminated CMC components through shell subelement techniques
NASA Technical Reports Server (NTRS)
Starlinger, Alois; Duffy, Stephen F.; Gyekenyesi, John P.
1992-01-01
An updated version of the integrated design program Composite Ceramics Analysis and Reliability Evaluation of Structures (C/CARES) was developed for the reliability evaluation of ceramic matrix composites (CMC) laminated shell components. The algorithm is now split into two modules: a finite-element data interface program and a reliability evaluation algorithm. More flexibility is achieved, allowing for easy implementation with various finite-element programs. The interface program creates a neutral data base which is then read by the reliability module. This neutral data base concept allows easy data transfer between different computer systems. The new interface program from the finite-element code Matrix Automated Reduction and Coupling (MARC) also includes the option of using hybrid laminates (a combination of plies of different materials or different layups) and allows for variations in temperature fields throughout the component. In the current version of C/CARES, a subelement technique was implemented, enabling stress gradients within an element to be taken into account. The noninteractive reliability function is now evaluated at each Gaussian integration point instead of using averaging techniques. As a result of the increased number of stress evaluation points, considerable improvements in the accuracy of reliability analyses were realized.
Beardsley, Chris; Egerton, Tim; Skinner, Brendon
2016-01-01
Objective. The purpose of this study was to investigate the reliability of a digital pelvic inclinometer (DPI) for measuring sagittal plane pelvic tilt in 18 young, healthy males and females. Method. The inter-rater reliability and test-re-test reliabilities of the DPI for measuring pelvic tilt in standing on both the right and left sides of the pelvis were measured by two raters carrying out two rating sessions of the same subjects, three weeks apart. Results. For measuring pelvic tilt, inter-rater reliability was designated as good on both sides (ICC = 0.81-0.88), test-re-test reliability within a single rating session was designated as good on both sides (ICC = 0.88-0.95), and test-re-test reliability between two rating sessions was designated as moderate on the left side (ICC = 0.65) and good on the right side (ICC = 0.85). Conclusion. Inter-rater reliability and test-re-test reliability within a single rating session of the DPI in measuring pelvic tilt were both good, while test-re-test reliability between rating sessions was moderate-to-good. Caution is required regarding the interpretation of the test-re-test reliability within a single rating session, as the raters were not blinded. Further research is required to establish validity.
FabricS: A user-friendly, complete and robust software for particle shape-fabric analysis
NASA Astrophysics Data System (ADS)
Moreno Chávez, G.; Castillo Rivera, F.; Sarocchi, D.; Borselli, L.; Rodríguez-Sedano, L. A.
2018-06-01
Shape-fabric is a textural parameter related to the spatial arrangement of elongated particles in geological samples. Its usefulness spans a range from sedimentary petrology to igneous and metamorphic petrology. Independently of the process being studied, when a material flows, the elongated particles are oriented with the major axis in the direction of flow. In sedimentary petrology this information has been used for studies of paleo-flow direction of turbidites, the origin of quartz sediments, and locating ignimbrite vents, among others. In addition to flow direction and its polarity, the method enables flow rheology to be inferred. The use of shape-fabric has been limited due to the difficulties of automatically measuring particles and analyzing them with reliable circular statistics programs. This has dampened interest in the method for a long time. Shape-fabric measurement has increased in popularity since the 1980s thanks to the development of new image analysis techniques and circular statistics software. However, the programs currently available are unreliable, old and are incompatible with newer operating systems, or require programming skills. The goal of our work is to develop a user-friendly program, in the MATLAB environment, with a graphical user interface, that can process images and includes editing functions, and thresholds (elongation and size) for selecting a particle population and analyzing it with reliable circular statistics algorithms. Moreover, the method also has to produce rose diagrams, orientation vectors, and a complete series of statistical parameters. All these requirements are met by our new software. In this paper, we briefly explain the methodology from collection of oriented samples in the field to the minimum number of particles needed to obtain reliable fabric data. We obtained the data using specific statistical tests and taking into account the degree of iso-orientation of the samples and the required degree of reliability. The program has been verified by means of several simulations performed using appropriately designed features and by analyzing real samples.
Evaluation of the Transit Reliability Information Program
DOT National Transportation Integrated Search
1982-06-01
This report presents an evaluation of the rail portion of the Transit Reliability Information Program (TRIP), which was designed to collect and analyze equipment reliability data on U.S. transit systems. This assessment was conducted at the end of it...
Ammerlaan, Judy W; van Os-Medendorp, Harmieke; Sont, Jacob K; Elsworth, Gerald R; Osborne, Richard H
2017-01-31
The Health Education Impact Questionnaire (heiQ) evaluates the effectiveness of health education and self-management programs provided to people dealing with a wide range of conditions. Aim of this study was to translate, culturally adapt and validate the Dutch translation of the heiQ and to compare the results with the English, German and French translations. A systematic translation process was undertaken. Psychometric properties were studied among patients with arthritis, atopic dermatitis, food allergy and asthma (n = 286). Factorial validity using confirmatory factor analysis, item difficulty (D), item remainder correlation and composite reliability were conducted. Stability was tested using the intra-class correlation coefficient (ICC). Items were well understood and only minor language adjustments were required. Confirmatory fit indices were >0.95 and item difficulty was D ≥ 0.65 for all items in scales showing acceptable fit indices, except for the reversed Emotional distress scale. Composite reliability ranged between 0.67 and 0.85. Test-retest reliability (n = 93) ICC varied between 0.61 and 0.84. Comparisons with other translations showed comparable fit indices. A lower ICC on Self-monitoring and insight scale was observed. The Dutch translation of the heiQ was found to be well understood and user friendly by patients with Rheumatoid Arthritis, Atopic Dermatitis, Food allergy and asthma and to have robust psychometric properties for evaluating the impact of health education and self-management programs. Given the wide applications of the heiQ and the comparability of the Dutch results with the English, German and French version, the heiQ is a practical and useful questionnaire to evaluate the impact of self-management support programs in different countries and populations with different diseases.
Specvis: Free and open-source software for visual field examination.
Dzwiniel, Piotr; Gola, Mateusz; Wójcik-Gryciuk, Anna; Waleszczyk, Wioletta J
2017-01-01
Visual field impairment affects more than 100 million people globally. However, due to the lack of the access to appropriate ophthalmic healthcare in undeveloped regions as a result of associated costs and expertise this number may be an underestimate. Improved access to affordable diagnostic software designed for visual field examination could slow the progression of diseases, such as glaucoma, allowing for early diagnosis and intervention. We have developed Specvis, a free and open-source application written in Java programming language that can run on any personal computer to meet this requirement (http://www.specvis.pl/). Specvis was tested on glaucomatous, retinitis pigmentosa and stroke patients and the results were compared to results using the Medmont M700 Automated Static Perimeter. The application was also tested for inter-test intrapersonal variability. The results from both validation studies indicated low inter-test intrapersonal variability, and suitable reliability for a fast and simple assessment of visual field impairment. Specvis easily identifies visual field areas of zero sensitivity and allows for evaluation of its levels throughout the visual field. Thus, Specvis is a new, reliable application that can be successfully used for visual field examination and can fill the gap between confrontation and perimetry tests. The main advantages of Specvis over existing methods are its availability (free), affordability (runs on any personal computer), and reliability (comparable to high-cost solutions).
Specvis: Free and open-source software for visual field examination
Dzwiniel, Piotr; Gola, Mateusz; Wójcik-Gryciuk, Anna
2017-01-01
Visual field impairment affects more than 100 million people globally. However, due to the lack of the access to appropriate ophthalmic healthcare in undeveloped regions as a result of associated costs and expertise this number may be an underestimate. Improved access to affordable diagnostic software designed for visual field examination could slow the progression of diseases, such as glaucoma, allowing for early diagnosis and intervention. We have developed Specvis, a free and open-source application written in Java programming language that can run on any personal computer to meet this requirement (http://www.specvis.pl/). Specvis was tested on glaucomatous, retinitis pigmentosa and stroke patients and the results were compared to results using the Medmont M700 Automated Static Perimeter. The application was also tested for inter-test intrapersonal variability. The results from both validation studies indicated low inter-test intrapersonal variability, and suitable reliability for a fast and simple assessment of visual field impairment. Specvis easily identifies visual field areas of zero sensitivity and allows for evaluation of its levels throughout the visual field. Thus, Specvis is a new, reliable application that can be successfully used for visual field examination and can fill the gap between confrontation and perimetry tests. The main advantages of Specvis over existing methods are its availability (free), affordability (runs on any personal computer), and reliability (comparable to high-cost solutions). PMID:29028825
A Survey of Clinical Faculty Calibration in Dental Hygiene Programs.
Dicke, Nichole L; Hodges, Kathleen O; Rogo, Ellen J; Hewett, Beverly J
2015-08-01
This study investigated the calibration efforts of entry-level dental hygiene programs in the U.S. Four aspects were explored, including attitudes, characteristics, quality and satisfaction, to evaluate current calibration practices. A descriptive comparative survey design was used. Directors of accredited dental hygiene programs (n=345) were asked to forward an electronic survey invitation to clinical faculty. Eighty-five directors forwarded the survey to 847 faculty; 45.3% (n=384) participated. The 37-item survey contained multiple-choice and Likert scale questions and was available for 3 weeks. Descriptive statistics were used to analyze demographic data and research questions. The Kruskal-Wallis, Spearman Correlation Coefficient and Mann-Whitney U tests were employed to analyze hypotheses (p=0.05). The demographic profile for participants revealed that most worked for institutions awarding associate entry-level degrees, had 1 to 10 years' experience, taught clinically and didactically, and held a master's degree. Clinical instructors valued calibration, believed it reduced variation and wanted more calibration. Some were not offered quality calibration. There was a difference between the entry-level degree awarded and the program's evaluation of clinical skill faculty reliability, as analyzed using the Kruskal-Wallis test (p=0.008). Additionally, full-time versus part-time educators reported more observed student frustration with faculty variance, as evaluated using the Mann-Whitney U test (p=0.001, bfp=0.004). Faculty members value calibration's potential benefits and want enhanced calibration efforts. Calibration efforts need to be improved to include standards for measuring intra- and inter-rater reliability and plans for resolving inconsistencies. More research is needed to determine effective calibration methods and their impact on student learning. Copyright © 2015 The American Dental Hygienists’ Association.
Development and validity of a scale to measure workplace culture of health.
Kwon, Youngbum; Marzec, Mary L; Edington, Dee W
2015-05-01
To describe the development of and test the validity and reliability of the Workplace Culture of Health (COH) scale. Exploratory factor analysis and confirmatory factor analysis were performed on data from a health care organization (N = 627). To verify the factor structure, confirmatory factor analysis was performed on a second data set from a medical equipment manufacturer (N = 226). The COH scale included a structure of five orthogonal factors: senior leadership and polices, programs and rewards, quality assurance, supervisor support, and coworker support. With regard to construct validity (convergent and discriminant) and reliability, two different US companies showed the same factorial structure, satisfactory fit statistics, and suitable internal and external consistency. The COH scale represents a reliable and valid scale to assess the workplace environment and culture for supporting health.
Tarescavage, Anthony M; Scheman, Judith; Ben-Porath, Yossef S
2015-06-01
The purpose of the current study was to investigate the reliability and concurrent validity of Minnesota Multiphasic Personality Inventory (MMPI)-2-Restructured Form (2-RF) (Ben-Porath & Tellegen, 2008/2011) scores in a sample of 811 chronic low back pain patients (346 males, 529 females) beginning treatment in a short-term interdisciplinary pain rehabilitation program. We calculated internal consistency coefficients, mean-item correlations, and SEM for all substantive scales, as well as zero-order correlations with collateral medical record information and self-report testing. Results indicated reliability and validity for most of the MMPI-2-RF substantive scales. Implications of these findings and limitations of this study are discussed. (c) 2015 APA, all rights reserved).
ERIC Educational Resources Information Center
Jones, Corinne A.; Hoffman, Matthew R.; Geng, Zhixian; Abdelhalim, Suzan M.; Jiang, Jack J.; McCulloch, Timothy M.
2014-01-01
Purpose: The purpose of this study was to investigate inter- and intrarater reliability among expert users, novice users, and speech-language pathologists with a semiautomated high-resolution manometry analysis program. We hypothesized that all users would have high intrarater reliability and high interrater reliability. Method: Three expert…
Yamamoto, Ryo; Kizawa, Yoshiyuki; Nakazawa, Yoko; Morita, Tatsuya
2013-11-01
In Japan, a nationwide palliative care education program for primary palliative care (the Palliative care Emphasis program on symptom management and Assessment for Continuous medical Education: PEACE) was established in 2008. Effective delivery of such programs relies on adequate evaluations of program efficacy; however, such an instrument does not exist. This study aimed to develop and validate a measurement tool to quantify knowledge level of physicians about broader areas of palliative care, by which the effect of an education program could be measured. We conducted a cross-sectional, anonymous, self-administered questionnaire survey with a group of 801 conveniently sampled physicians in October 2010. To examine the test-retest reliability of items and domains, the questionnaire was reissued two weeks after the first survey was completed. This study used psychometric methods, including item response theory, intraclass correlation coefficients, and known-group validity. The response rate was 54% (n=434). We included 33 items across the following 9 domains: (1) philosophy of palliative care, (2) cancer pain, (3) side effects of opioids, (4) dyspnea, (5) nausea and vomiting, (6) psychological distress, (7) delirium, (8) communication regarding palliative care, and (9) community-based palliative care. For these items, the intraclass correlation was 0.84 and the Kuder-Richardson Formula 20 (KR-20) test of internal consistency was 0.87. There was a significant difference in the scores between palliative care specialists and other physicians. We successfully validated a newly developed palliative care knowledge questionnaire to evaluate PEACE effectiveness (PEACE-Q). The PEACE-Q could be useful for evaluating both palliative care knowledge among physicians and education programs in primary palliative care.
[A test to measure the degree of knowledge on food and nutrition at the onset of elementary school].
Ivanovic Marincovich, D; Castro Gómez, C G; Ivanovic Marincovich, R
1997-06-01
The objective of this work was to design a test to measure the degree of knowledge on food and nutrition in school-age children from elementary first and second grades. A graphic instrument was designed according to the psychological child development and was based on the specific objectives pursued by the curriculum programs of the Ministry of Education. The test was developed around the following topics through 15 items: Area 1: Basic Concepts on Food and Nutrition (9 items) and Area 2: Food, Personal and Environmental Hygiene (9 items). The test was pilot tested on 103 school-age children of both grades (1:1), of both sexes (1:1), belonging to Peñalolén and Las Condes counties from Chile's Metropolitan Region and from high and low socioeconomic status (SES) (1:1), measured through the Graffar's Modified Method. The final version of the test was applied in a representative sample of 1.482 school-age children from Chile's Metropolitan Region from elementary first and second grades during 1986-1987. Content validity was assured by a team of judges and by the curriculum programs. Reliability was assessed by the Spearman correlation with the Spearman-Brown correction. Item-test consistency was determined by the Pearson correlation coefficient. Data were processed by the statistical analysis system (SAS) package. Results showed that reliability coefficient was 0.84 and item-test consistency was equal or above 0.25 in all items. It can be concluded that this test can be useful to determine the degree of knowledge on food and nutrition at the onset of elementary school, both in Chile and in other countries.
Older adults' drug benefit beliefs: construct definition and measure development.
Cline, Richard R; Gupta, Kiran; Singh, Reshmi L
2008-03-01
The Medicare Prescription Drug, Improvement and Modernization Act of 2003 provides coverage of outpatient prescription drugs for Medicare beneficiaries. Although much has been learned since the program's implementation, a context within which this information can be understood is lacking. The purpose of this study was to develop a reliable and valid multi-item instrument measuring beliefs about Medicare prescription drug benefits. Survey items were generated using focus group transcripts, other surveys on the Medicare Part "D" program, and past studies of choice and satisfaction in drug insurance programs. Using data from the survey pilot test, item and reliability analyses were used to reduce and refine an initial pool of items. Data then were collected from a cross-sectional, mail survey of older adults living in Minnesota. Data were analyzed using exploratory factor analysis. Summated rating scales then were constructed and assessed further using reliability analyses. Construct validity of summated scales was examined by comparing scale scores across response categories of survey items that collected information on general political attitudes, perceptions of the Medicare Part "D" program, health status, and health care utilization and demographics. The adjusted response rate for the main survey was 55.98% (744/1329). Iterative factor analysis produced 2 interpretable scales. The first, termed "access/equity" (13 items, Cronbach's alpha=0.89) measures beliefs that a Medicare drug benefit should both provide affordable prescription drugs for beneficiaries and do this in a manner that is equitable for all participants. The second, termed "comprehensibility" (6 items, Cronbach's alpha=0.80) assesses beliefs that regulations governing a Medicare drug benefit should be easily understood. Discriminant validity tests suggest that these measures behave in a manner consistent with related research in these areas. Measures of 2 facets of older adults' drug benefit beliefs were developed using a multiple step procedure. Future research could focus on developing a better understanding of other facets of these beliefs and sound methods of measurement.
Ares I Upper Stage Pressure Tests in Wind Tunnel
NASA Technical Reports Server (NTRS)
2007-01-01
Under the goals of the Vision for Space Exploration, Ares I is a chief component of the cost-effective space transportation infrastructure being developed by NASA's Constellation Program. This transportation system will safely and reliably carry human explorers back to the moon, and then onward to Mars and other destinations in the solar system. The Ares I effort includes multiple project element teams at NASA centers and contract organizations around the nation, and is managed by the Exploration Launch Projects Office at NASA's Marshall Space Flight Center (MFSC). ATK Launch Systems near Brigham City, Utah, is the prime contractor for the first stage booster. ATK's subcontractor, United Space Alliance of Houston, is designing, developing and testing the parachutes at its facilities at NASA's Kennedy Space Center in Florida. NASA's Johnson Space Center in Houston hosts the Constellation Program and Orion Crew Capsule Project Office and provides test instrumentation and support personnel. Together, these teams are developing vehicle hardware, evolving proven technologies, and testing components and systems. Their work builds on powerful, reliable space shuttle propulsion elements and nearly a half-century of NASA space flight experience and technological advances. Ares I is an inline, two-stage rocket configuration topped by the Crew Exploration Vehicle, its service module, and a launch abort system. In this HD video image, the first stage reentry 1/2% model is undergoing pressure measurements inside the wind tunnel testing facility at MSFC. (Highest resolution available)
2007-08-09
Under the goals of the Vision for Space Exploration, Ares I is a chief component of the cost-effective space transportation infrastructure being developed by NASA's Constellation Program. This transportation system will safely and reliably carry human explorers back to the moon, and then onward to Mars and other destinations in the solar system. The Ares I effort includes multiple project element teams at NASA centers and contract organizations around the nation, and is managed by the Exploration Launch Projects Office at NASA's Marshall Space Flight Center (MFSC). ATK Launch Systems near Brigham City, Utah, is the prime contractor for the first stage booster. ATK's subcontractor, United Space Alliance of Houston, is designing, developing and testing the parachutes at its facilities at NASA's Kennedy Space Center in Florida. NASA's Johnson Space Center in Houston hosts the Constellation Program and Orion Crew Capsule Project Office and provides test instrumentation and support personnel. Together, these teams are developing vehicle hardware, evolving proven technologies, and testing components and systems. Their work builds on powerful, reliable space shuttle propulsion elements and nearly a half-century of NASA space flight experience and technological advances. Ares I is an inline, two-stage rocket configuration topped by the Crew Exploration Vehicle, its service module, and a launch abort system. This HD video image depicts confidence testing of a manufactured aluminum panel that will fabricate the Ares I upper stage barrel. In this test, bent aluminum is stressed to breaking point and thoroughly examined. The panels are manufactured by AMRO Manufacturing located in El Monte, California. (Highest resolution available)
2007-07-09
Under the goals of the Vision for Space Exploration, Ares I is a chief component of the cost-effective space transportation infrastructure being developed by NASA's Constellation Program. This transportation system will safely and reliably carry human explorers back to the moon, and then onward to Mars and other destinations in the solar system. The Ares I effort includes multiple project element teams at NASA centers and contract organizations around the nation, and is managed by the Exploration Launch Projects Office at NASA's Marshall Space Flight Center (MFSC). ATK Launch Systems near Brigham City, Utah, is the prime contractor for the first stage booster. ATK's subcontractor, United Space Alliance of Houston, is designing, developing and testing the parachutes at its facilities at NASA's Kennedy Space Center in Florida. NASA's Johnson Space Center in Houston hosts the Constellation Program and Orion Crew Capsule Project Office and provides test instrumentation and support personnel. Together, these teams are developing vehicle hardware, evolving proven technologies, and testing components and systems. Their work builds on powerful, reliable space shuttle propulsion elements and nearly a half-century of NASA space flight experience and technological advances. Ares I is an inline, two-stage rocket configuration topped by the Crew Exploration Vehicle, its service module, and a launch abort system. In this HD video image, an Ares I x-test involves the upper stage separating from the first stage. This particular test was conducted at the NASA Langley Research Center in July 2007. (Highest resolution available)
NASA Technical Reports Server (NTRS)
Yew, Calinda; Lui, Yan; Whitehouse, Paul; Banks, Kimberly
2016-01-01
JWST Integrated Science Instruments Module (ISIM) completed its system-level space simulation testing program at the NASA Goddard Space Flight Center (GSFC). In March 2016, ISIM was successfully delivered to the next level of integration with the Optical Telescope Element (OTE), to form OTIS (OTE + ISIM), after concluding a series of three cryo-vacuum (CV) tests. During these tests, the complexity of the mission has generated challenging requirements that demand highly reliable system performance and capabilities from the Space Environment Simulator (SES) vacuum chamber. The first test served as a risk reduction test; the second test provided the initial verification of the fully-integrated flight instruments; and the third test verified the system in its final flight configuration following mechanical environmental tests (vibration and acoustics). From one test to the next, shortcomings of the facility were uncovered and associated improvements in operational capabilities and reliability of the facility were required to enable the project to verify system-level requirements. This paper: (1) provides an overview of the integrated mechanical and thermal facility systems required to achieve the objectives of JWST ISIM testing, (2) compares the overall facility performance and instrumentation results from the three ISIM CV tests, and (3) summarizes lessons learned from the ISIM testing campaign.
Improved silicon carbide for advanced heat engines
NASA Technical Reports Server (NTRS)
Whalen, Thomas J.
1988-01-01
This is the third annual technical report for the program entitled, Improved Silicon Carbide for Advanced Heat Engines, for the period February 16, 1987 to February 15, 1988. The objective of the original program was the development of high strength, high reliability silicon carbide parts with complex shapes suitable for use in advanced heat engines. Injection molding is the forming method selected for the program because it is capable of forming complex parts adaptable for mass production on an economically sound basis. The goals of the revised program are to reach a Weibull characteristic strength of 550 MPa (80 ksi) and a Weibull modulus of 16 for bars tested in 4-point loading. Two tasks are discussed: Task 1 which involves materials and process improvements, and Task 2 which is a MOR bar matrix to improve strength and reliability. Many statistically designed experiments were completed under task 1 which improved the composition of the batches, the mixing of the powders, the sinter and anneal cycles. The best results were obtained by an attritor mixing process which yielded strengths in excess of 550 MPa (80 ksi) and an individual Weibull modulus of 16.8 for a 9-sample group. Strengths measured at 1200 and 1400 C were equal to the room temperature strength. Annealing of machined test bars significantly improved the strength. Molding yields were measured and flaw distributions were observed to follow a Poisson process. The second iteration of the Task 2 matrix experiment is described.
Estimated Student Score Gain on the ACT COMP Exam: Valid Tool for Institutional Assessment?
ERIC Educational Resources Information Center
Banta, Trudy W.; And Others
1987-01-01
An institution can test seniors with the ACT College Outcome Measures Project (COMP) exam, then subtract from the senior score an estimated freshman score. Studies at the University of Tennessee, Knoxville, indicate that this method is not reliable to make judgments about the quality of general education programs. (Author/MLW)
DITT: a computer program for Data Interpretation for Torsional Tests
Chen, Albert T.F.
1979-01-01
Measurements of the helium concentration of soil samples collected and stored in Vacutainer-brand evacuated glass tubes show that Vacutainers are reliable containers for soil collection. Within the limits of reproducibility, helium content of soils appears to be independent of variations in soil temperature, barometric pressure, and quantity of soil moisture present in the sample.
Tests of the Validity and Reliability of the Community Service Attitudes Scale
ERIC Educational Resources Information Center
Perry, Brian; Osbaldiston, Richard; Henning, Jaime
2014-01-01
Community service is deeply rooted in American culture. There have been repeated calls for the necessity of evaluating these programs, especially for service-learning. The purpose of this research was to validate an easy-to-use scale that measures 10 components of students' attitudes toward community service. The sample was drawn from two…
Report on the Formal Trialling of the Australian Second Language Proficiency Ratings (ASLPR).
ERIC Educational Resources Information Center
Ingram, D. E.
Results of testing the validity and reliability of the Australian second language proficiency ratings (ASLPR) are presented. In addition to providing a framework for planning English as a second language programs for immigrants to Australia, the ASLPR was developed to specify second language proficiency in terms of practical language skills. The…
USDA-ARS?s Scientific Manuscript database
The prevalence of overweight in African American (AA) girls is higher than other ethnic groups. Increasing physical activity (PA) or decreasing energy intake is the goal of obesity prevention programs. Identifying factors that influence PA behavior is an important step in developing successful obesi...
Implementation of R & QA practices in Research and Development programs
NASA Technical Reports Server (NTRS)
Bankaitis, H.
1983-01-01
DOE has established a number of broad programs aimed at reducing fuel consumption. Several programs address the R&D of ground transportation propulsion alternatives to the conventional spark-ignition engine. NASA Lewis is responsible for managing the effort between the Government and industry teams involving American and foreign companies. Thus, existing NASA SR&QA procedure were modified/adapted to these R&D programs and implemented to assure that the test hardware design intent was met, the hardware was not hazardous to personnel, it would demonstrate reliable operation, and it would help establish the future R&D quality assurance and maintainability requirements. This successful low-cost approach might be applicable to other similar projects.
DOT National Transportation Integrated Search
2014-01-01
The second Strategic Highway Research Program (SHRP 2) Reliability program aims to improve trip time reliability by reducing the frequency and effects of events that cause travel times to fluctuate unpredictably. Congestion caused by unreliable, or n...
Basis And Application Of The CARES/LIFE Computer Program
NASA Technical Reports Server (NTRS)
Nemeth, Noel N.; Janosik, Lesley A.; Gyekenyesi, John P.; Powers, Lynn M.
1996-01-01
Report discusses physical and mathematical basis of Ceramics Analysis and Reliability Evaluation of Structures LIFE prediction (CARES/LIFE) computer program, described in "Program for Evaluation of Reliability of Ceramic Parts" (LEW-16018).
Ultimately Reliable Pyrotechnic Systems
NASA Technical Reports Server (NTRS)
Scott, John H.; Hinkel, Todd
2015-01-01
This paper presents the methods by which NASA has designed, built, tested, and certified pyrotechnic devices for high reliability operation in extreme environments and illustrates the potential applications in the oil and gas industry. NASA's extremely successful application of pyrotechnics is built upon documented procedures and test methods that have been maintained and developed since the Apollo Program. Standards are managed and rigorously enforced for performance margins, redundancy, lot sampling, and personnel safety. The pyrotechnics utilized in spacecraft include such devices as small initiators and detonators with the power of a shotgun shell, detonating cord systems for explosive energy transfer across many feet, precision linear shaped charges for breaking structural membranes, and booster charges to actuate valves and pistons. NASA's pyrotechnics program is one of the more successful in the history of Human Spaceflight. No pyrotechnic device developed in accordance with NASA's Human Spaceflight standards has ever failed in flight use. NASA's pyrotechnic initiators work reliably in temperatures as low as -420 F. Each of the 135 Space Shuttle flights fired 102 of these initiators, some setting off multiple pyrotechnic devices, with never a failure. The recent landing on Mars of the Opportunity rover fired 174 of NASA's pyrotechnic initiators to complete the famous '7 minutes of terror.' Even after traveling through extreme radiation and thermal environments on the way to Mars, every one of them worked. These initiators have fired on the surface of Titan. NASA's design controls, procedures, and processes produce the most reliable pyrotechnics in the world. Application of pyrotechnics designed and procured in this manner could enable the energy industry's emergency equipment, such as shutoff valves and deep-sea blowout preventers, to be left in place for years in extreme environments and still be relied upon to function when needed, thus greatly enhancing safety and operational availability.
Cohen, Harvey J.; Popat, Rita A.; Halamek, Louis P.
2015-01-01
Abstract Background: Interventions to improve pediatric trainee education in palliative care have been limited by a lack of reliable and valid tools for measuring effectiveness. Objective: We developed a questionnaire to measure pediatric fellows' self-efficacy (comfort), knowledge, and perceived adequacy of prior medical education. We measured the questionnaire's reliability and validity. Methods: The questionnaire contains questions regarding self-efficacy (23), knowledge (10), fellow's perceived adequacy of prior medical education (6), and demographics. The survey was developed with palliative care experts, and sent to fellows in U.S. pediatric cardiology, critical care, hematology/ oncology, and neonatal-perinatal medicine programs. Measures of reliability, internal consistency, and validity were calculated. Results: One hundred forty-seven fellows completed the survey at test and retest. The self-efficacy and medical education questionnaires showed high internal consistency of 0.95 and 0.84. The test-retest reliability for the Self-Efficacy Summary Score, measured by intraclass correlation coefficient (ICC) and weighted kappa, was 0.78 (item range 0.44–0.81) and 0.61 (item range 0.36–0.70), respectively. For the Adequacy of Medical Education Summary Score, ICC was 0.85 (item range 0.6–0.78) and weighted kappa was 0.63 (item range 0.47–0.62). Validity coefficients for these two questionnaires were 0.88 and 0.92. Fellows answered a mean of 8.8/10 knowledge questions correctly; percentage agreement ranged from 65% to 99%. Conclusions: This questionnaire is capable of assessing self-efficacy and fellow-perceived adequacy of their prior palliative care training. We recommend use of this tool for fellowship programs seeking to evaluate fellow education in palliative care, or for research studies assessing the effectiveness of a palliative care educational intervention. PMID:26185912
Structural Reliability Using Probability Density Estimation Methods Within NESSUS
NASA Technical Reports Server (NTRS)
Chamis, Chrisos C. (Technical Monitor); Godines, Cody Ric
2003-01-01
A reliability analysis studies a mathematical model of a physical system taking into account uncertainties of design variables and common results are estimations of a response density, which also implies estimations of its parameters. Some common density parameters include the mean value, the standard deviation, and specific percentile(s) of the response, which are measures of central tendency, variation, and probability regions, respectively. Reliability analyses are important since the results can lead to different designs by calculating the probability of observing safe responses in each of the proposed designs. All of this is done at the expense of added computational time as compared to a single deterministic analysis which will result in one value of the response out of many that make up the density of the response. Sampling methods, such as monte carlo (MC) and latin hypercube sampling (LHS), can be used to perform reliability analyses and can compute nonlinear response density parameters even if the response is dependent on many random variables. Hence, both methods are very robust; however, they are computationally expensive to use in the estimation of the response density parameters. Both methods are 2 of 13 stochastic methods that are contained within the Numerical Evaluation of Stochastic Structures Under Stress (NESSUS) program. NESSUS is a probabilistic finite element analysis (FEA) program that was developed through funding from NASA Glenn Research Center (GRC). It has the additional capability of being linked to other analysis programs; therefore, probabilistic fluid dynamics, fracture mechanics, and heat transfer are only a few of what is possible with this software. The LHS method is the newest addition to the stochastic methods within NESSUS. Part of this work was to enhance NESSUS with the LHS method. The new LHS module is complete, has been successfully integrated with NESSUS, and been used to study four different test cases that have been proposed by the Society of Automotive Engineers (SAE). The test cases compare different probabilistic methods within NESSUS because it is important that a user can have confidence that estimates of stochastic parameters of a response will be within an acceptable error limit. For each response, the mean, standard deviation, and 0.99 percentile, are repeatedly estimated which allows confidence statements to be made for each parameter estimated, and for each method. Thus, the ability of several stochastic methods to efficiently and accurately estimate density parameters is compared using four valid test cases. While all of the reliability methods used performed quite well, for the new LHS module within NESSUS it was found that it had a lower estimation error than MC when they were used to estimate the mean, standard deviation, and 0.99 percentile of the four different stochastic responses. Also, LHS required a smaller amount of calculations to obtain low error answers with a high amount of confidence than MC. It can therefore be stated that NESSUS is an important reliability tool that has a variety of sound probabilistic methods a user can employ and the newest LHS module is a valuable new enhancement of the program.
Advanced Simulation and Computing Fiscal Year 2016 Implementation Plan, Version 0
DOE Office of Scientific and Technical Information (OSTI.GOV)
McCoy, M.; Archer, B.; Hendrickson, B.
2015-08-27
The Stockpile Stewardship Program (SSP) is an integrated technical program for maintaining the safety, surety, and reliability of the U.S. nuclear stockpile. The SSP uses nuclear test data, computational modeling and simulation, and experimental facilities to advance understanding of nuclear weapons. It includes stockpile surveillance, experimental research, development and engineering programs, and an appropriately scaled production capability to support stockpile requirements. This integrated national program requires the continued use of experimental facilities and programs, and the computational capabilities to support these programs. The purpose of this IP is to outline key work requirements to be performed and to control individualmore » work activities within the scope of work. Contractors may not deviate from this plan without a revised WA or subsequent IP.« less
Evaluation of on-campus continuing medical education programs in Alberta
Hazlett, C. B.; Bachynski, J. E.; Embleton, J.
1973-01-01
Seven on-campus continuing medical education programs offered during the 1971-72 academic year were evaluated. A multiple-choice examination was taken by the participants before each course; the same examination was administered immediately after the course was completed, and a third examination was taken three to five months later. It was found that for each course there was a significant increase in knowledge at both post-testing periods. A questionnaire developed for the purpose of determining the effectiveness of the courses was also administered at the time of the third test, and exhibited reasonable degrees of reliability and validity. A large proportion of the participants indicated the content of their courses was relevant and necessary, and was being used in their medical practice. It was concluded that the effectiveness of these programs justified their continuation. PMID:4704095
Composite Overwrapped Pressure Vessel (COPV) Stress Rupture Testing
NASA Technical Reports Server (NTRS)
Greene, Nathanael J.; Saulsberry, Regor L.; Leifeste, Mark R.; Yoder, Tommy B.; Keddy, Chris P.; Forth, Scott C.; Russell, Rick W.
2010-01-01
This paper reports stress rupture testing of Kevlar(TradeMark) composite overwrapped pressure vessels (COPVs) at NASA White Sands Test Facility. This 6-year test program was part of the larger effort to predict and extend the lifetime of flight vessels. Tests were performed to characterize control parameters for stress rupture testing, and vessel life was predicted by statistical modeling. One highly instrumented 102-cm (40-in.) diameter Kevlar(TradeMark) COPV was tested to failure (burst) as a single-point model verification. Significant data were generated that will enhance development of improved NDE methods and predictive modeling techniques, and thus better address stress rupture and other composite durability concerns that affect pressure vessel safety, reliability and mission assurance.
Meterko, Mark; Young, Gary J; White, Bert; Bokhour, Barbara G; Burgess, James F; Berlowitz, Dan; Guldin, Matthew R; Nealon Seibert, Marjorie
2006-01-01
Objective To develop an instrument for assessing physician attitudes toward quality incentive programs, and to assess its reliability and validity. Data Sources Study involved primary data collection. A 40-item paper and pencil survey of primary care physicians in Rochester, New York, and Massachusetts was conducted between May 2004 and December 2004. Seven-hundred and ninety-eight completed questionnaires were received, representing a response rate of 32 percent (798/2,497). Study Design Based on an extensive review of the literature and discussions with experts in the field, we developed a conceptual framework representing the features of pay-for-performance (P4P) programs hypothesized to affect physician behavior in that context. A draft questionnaire was developed based on that conceptual model and pilot tested in three groups of physicians. The questionnaire was modified based on the physician feedback, and the revised version was distributed to 2,497 primary care physicians affiliated with two of the seven sites participating in Rewarding Results, a national evaluation of quality target and financial incentive programs. Data Collection Respondents were randomly divided into a derivation and a validation sample. Exploratory factor analysis was applied to the responses of the derivation sample. Those results were used to create scales in the validation sample, and these were then subjected to multitrait analysis (MTA). One scale representing physicians' perception of the impact of P4P on their clinical practice was regressed on the other scales as a test of construct validity. Principal Findings Seven constructs were identified and demonstrated substantial convergent and discriminant validity in the MTA: awareness and understanding, clinical relevance, cooperation, unintended consequences, control, financial salience, and impact. Internal consistency reliabilities (Cronbach's α coefficients) ranged from 0.50 to 0.80. A statistically significant 25 percent of the variation in perceived impact was accounted for by physician perceptions of the other six characteristics of P4P programs. Conclusions It is possible to identify and measure the key salient features of P4P programs using a valid and reliable 26-item survey. This instrument may now be used in further studies to better understand the impact of P4P programs on physician behavior. PMID:16987311
Apollo experience report: Reliability and quality assurance
NASA Technical Reports Server (NTRS)
Sperber, K. P.
1973-01-01
The reliability of the Apollo spacecraft resulted from the application of proven reliability and quality techniques and from sound management, engineering, and manufacturing practices. Continual assessment of these techniques and practices was made during the program, and, when deficiencies were detected, adjustments were made and the deficiencies were effectively corrected. The most significant practices, deficiencies, adjustments, and experiences during the Apollo Program are described in this report. These experiences can be helpful in establishing an effective base on which to structure an efficient reliability and quality assurance effort for future space-flight programs.
Wan, Chonghua; Li, Hezhan; Fan, Xuejin; Yang, Ruixue; Pan, Jiahua; Chen, Wenru; Zhao, Rong
2014-06-04
Quality of life (QOL) for patients with coronary heart disease (CHD) is now concerned worldwide with the specific instruments being seldom and no one developed by the modular approach. This paper is aimed to develop the CHD scale of the system of Quality of Life Instruments for Chronic Diseases (QLICD-CHD) by the modular approach and validate it by both classical test theory and Generalizability Theory. The QLICD-CHD was developed based on programmed decision procedures with multiple nominal and focus group discussions, in-depth interview, pre-testing and quantitative statistical procedures. 146 inpatients with CHD were used to provide the data measuring QOL three times before and after treatments. The psychometric properties of the scale were evaluated with respect to validity, reliability and responsiveness employing correlation analysis, factor analyses, multi-trait scaling analysis, t-tests and also G studies and D studies of Genralizability Theory analysis. Multi-trait scaling analysis, correlation and factor analyses confirmed good construct validity and criterion-related validity when using SF-36 as a criterion. The internal consistency α and test-retest reliability coefficients (Pearson r and Intra-class correlations ICC) for the overall instrument and all domains were higher than 0.70 and 0.80 respectively; The overall and all domains except for social domain had statistically significant changes after treatments with moderate effect size SRM (standardized response mea) ranging from 0.32 to 0.67. G-coefficients and index of dependability (Ф coefficients) confirmed the reliability of the scale further with more exact variance components. The QLICD-CHD has good validity, reliability, and moderate responsiveness and some highlights, and can be used as the quality of life instrument for patients with CHD. However, in order to obtain better reliability, the numbers of items for social domain should be increased or the items' quality, not quantity, should be improved.
A low-cost programmable pulse generator for physiology and behavior
Sanders, Joshua I.; Kepecs, Adam
2014-01-01
Precisely timed experimental manipulations of the brain and its sensory environment are often employed to reveal principles of brain function. While complex and reliable pulse trains for temporal stimulus control can be generated with commercial instruments, contemporary options remain expensive and proprietary. We have developed Pulse Pal, an open source device that allows users to create and trigger software-defined trains of voltage pulses with high temporal precision. Here we describe Pulse Pal’s circuitry and firmware, and characterize its precision and reliability. In addition, we supply online documentation with instructions for assembling, testing and installing Pulse Pal. While the device can be operated as a stand-alone instrument, we also provide application programming interfaces in several programming languages. As an inexpensive, flexible and open solution for temporal control, we anticipate that Pulse Pal will be used to address a wide range of instrumentation timing challenges in neuroscience research. PMID:25566051
DERAKHSHANDEH, ZAHRA; AMINI, MITRA; KOJURI, JAVAD; DEHBOZORGIAN, MARZIYEH
2018-01-01
Introduction: Clinical reasoning is one of the most important skills in the process of training a medical student to become an efficient physician. Assessment of the reasoning skills in a medical school program is important to direct students’ learning. One of the tests for measuring the clinical reasoning ability is Clinical Reasoning Problems (CRPs). The major aim of this study is to measure psychometric qualities of CRPs and define correlation between this test and routine MCQ in cardiology department of Shiraz medical school. Methods: This study was a descriptive study conducted on total cardiology residents of Shiraz Medical School. The study population consists of 40 residents in 2014. The routine CRPs and the MCQ tests was designed based on similar objectives and were carried out simultaneously. Reliability, item difficulty, item discrimination, and correlation between each item and the total score of CRPs were all measured by Excel and SPSS software for checking psycometeric CRPs test. Furthermore, we calculated the correlation between CRPs test and MCQ test. The mean differences of CRPs test score between residents’ academic year [second, third and fourth year] were also evaluated by Analysis of variances test (One Way ANOVA) using SPSS software (version 20)(α=0.05). Results: The mean and standard deviation of score in CRPs was 10.19 ±3.39 out of 20; in MCQ, it was 13.15±3.81 out of 20. Item difficulty was in the range of 0.27-0.72; item discrimination was 0.30-0.75 with question No.3 being the exception (that was 0.24). The correlation between each item and the total score of CRP was 0.26-0.87; the correlation between CRPs test and MCQ test was 0.68 (p<0.001). The reliability of the CRPs was 0.72 as calculated by using Cronbach's alpha. The mean score of CRPs was different among residents based on their academic year and this difference was statistically significant (p<0.001). Conclusion: The results of this present investigation revealed that CRPs could be reliable test for measuring clinical reasoning in residents. It can be included in cardiology residency assessment programs. PMID:29344528
Jordan, Denis; Steiner, Marcel; Kochs, Eberhard F; Schneider, Gerhard
2010-12-01
Prediction probability (P(K)) and the area under the receiver operating characteristic curve (AUC) are statistical measures to assess the performance of anesthetic depth indicators, to more precisely quantify the correlation between observed anesthetic depth and corresponding values of a monitor or indicator. In contrast to many other statistical tests, they offer several advantages. First, P(K) and AUC are independent from scale units and assumptions on underlying distributions. Second, the calculation can be performed without any knowledge about particular indicator threshold values, which makes the test more independent from specific test data. Third, recent approaches using resampling methods allow a reliable comparison of P(K) or AUC of different indicators of anesthetic depth. Furthermore, both tests allow simple interpretation, whereby results between 0 and 1 are related to the probability, how good an indicator separates the observed levels of anesthesia. For these reasons, P(K) and AUC have become popular in medical decision making. P(K) is intended for polytomous patient states (i.e., >2 anesthetic levels) and can be considered as a generalization of the AUC, which was basically introduced to assess a predictor of dichotomous classes (e.g., consciousness and unconsciousness in anesthesia). Dichotomous paradigms provide equal values of P(K) and AUC test statistics. In the present investigation, we introduce a user-friendly computer program for computing P(K) and estimating reliable bootstrap confidence intervals. It is designed for multiple comparisons of the performance of depth of anesthesia indicators. Additionally, for dichotomous classes, the program plots the receiver operating characteristic graph completing information obtained from P(K) or AUC, respectively. In clinical investigations, both measures are applied for indicator assessment, where ambiguous usage and interpretation may be a consequence. Therefore, a summary of the concepts of P(K) and AUC including brief and easily understandable proof of their equality is presented in the text. The exposure introduces readers to the algorithms of the provided computer program and is intended to make standardized performance tests of depth of anesthesia indicators available to medical researchers.
Gower, Jared R; Moyer-Mileur, Laurie J; Wilkinson, Robert D; Slater, Hillarie; Jordan, Kristine C
2010-03-01
Limited surveys are available to assess the nutrition knowledge of children. The goals of this study were to test the validity and reliability of a computer nutrition knowledge survey for elementary school students and to evaluate the impact of the "Fit Kids 'r' Healthy Kids" nutrition intervention via the knowledge survey. During survey development, a sample (n=12) of health educators, elementary school teachers, and registered dietitians assessed the survey. The target population consisted of first- through fourth-grade students from Salt Lake City, UT, metropolitan area schools. Participants were divided into reliability (n=68), intervention (n=74), and control groups (n=59). The reliability group took the survey twice (2 weeks apart); the intervention and control groups also took the survey twice, but at pre- and post-intervention (4 weeks later). Only students from the intervention group participated in four weekly nutrition classes. Reliability was assessed by Pearson's correlation coefficients for knowledge scores. Results demonstrated appropriate content validity, as indicated by expert peer ratings. Test-retest reliability correlations were found to be significant for the overall survey (r=0.54; P<0.001) and for all subscales: food groups, healthful foods, and food functions (r=0.51, 0.65, and 0.49, respectively; P<0.001). Nutrition knowledge was assessed upon program completion with paired samples t tests. Students from the intervention group demonstrated improvement in nutrition knowledge (12.2+/-1.9 to 13.5+/-1.6; P<0.001), while scores for the control group remained unchanged. The difference in total scores from pre- to post-intervention between the two groups was significant (P<0.001). These results suggest that the computerized nutrition survey demonstrated content validity and test-retest reliability for first- through fourth-grade elementary school children. Also, the study results imply that the Fit Kids 'r' Healthy Kids intervention promoted gains in nutrition knowledge. Overall, the computer survey shows promise as an appealing medium for assessing nutrition knowledge in children. Copyright 2010 American Dietetic Association. Published by Elsevier Inc. All rights reserved.
Energy Efficient Engine exhaust mixer model technology report addendum; phase 3 test program
NASA Technical Reports Server (NTRS)
Larkin, M. J.; Blatt, J. R.
1984-01-01
The Phase 3 exhaust mixer test program was conducted to explore the trends established during previous Phases 1 and 2. Combinations of mixer design parameters were tested. Phase 3 testing showed that the best performance achievable within tailpipe length and diameter constraints is 2.55 percent better than an optimized separate flow base line. A reduced penetration design achieved about the same overall performance level at a substantially lower level of excess pressure loss but with a small reduction in mixing. To improve reliability of the data, the hot and cold flow thrust coefficient analysis used in Phases 1 and 2 was augmented by calculating percent mixing from traverse data. Relative change in percent mixing between configurations was determined from thrust and flow coefficient increments. The calculation procedure developed was found to be a useful tool in assessing mixer performance. Detailed flow field data were obtained to facilitate calibration of computer codes.
Catalytic ignition of hydrogen/oxygen
NASA Technical Reports Server (NTRS)
Green, James M.; Zurawski, Robert L.
1988-01-01
An experimental program was conducted to evaluate the catalytic ignition of gaseous hydrogen and oxygen. Shell 405 granular catalyst and a unique monolithic sponge catalyst were tested. Mixture ratio, mass flow rate, propellant inlet temperature, and back pressure were varied parametrically in testing to determine the operational limits of a catalytic igniter. The test results showed that the gaseous hydrogen/oxygen propellant combination can be ignited catalytically using Shell 405 catalyst over a wide range of mixture ratios, mass flow rates, and propellant injection temperatures. These operating conditions must be optimized to ensure reliable ignition for an extended period of time. The results of the experimental program and the established operational limits for a catalytic igniter using both the granular and monolithic catalysts are presented. The capabilities of a facility constructed to conduct the igniter testing and the advantages of a catalytic igniter over other ignition systems for gaseous hydrogen and oxygen are also discussed.
Ceramic regenerator systems development program
NASA Technical Reports Server (NTRS)
Fucinari, C. A.; Rahnke, C. J.; Rao, V. D. N.; Vallance, J. K.
1980-01-01
The DOE/NASA Ceramic Regenerator Design and Reliability Program aims to develop ceramic regenerator cores that can be used in passenger car and industrial/truck gas turbine engines. The major cause of failure of early gas turbine regenerators was found to be chemical attack of the ceramic material. Improved materials and design concepts aimed at reducing or eliminating chemical attack were placed on durability test in Ford 707 industrial gas turbine engines late in 1974. Results of 53,065 hours of turbine engine durability testing are described. Two materials, aluminum silicate and magnesium aluminum silicate, show promise. Five aluminum silicate cores attained the durability objective of 10,000 hours at 800 C (1472 F). Another aluminum silicate core shows minimal evidence of chemical attack after 8071 hours at 982 C (1800 F). Results obtained in ceramic material screening tests, aerothermodynamic performance tests, stress analysis, cost studies, and material specifications are included.